Sample records for reliable diagnostic method

  1. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    PubMed

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. (c) 2015 APA, all rights reserved).

  2. Reliability of Chinese medicine diagnostic variables in the examination of patients with osteoarthritis of the knee.

    PubMed

    Hua, Bin; Abbas, Estelle; Hayes, Alan; Ryan, Peter; Nelson, Lisa; O'Brien, Kylie

    2012-11-01

    Chinese medicine (CM) has its own diagnostic indicators that are used as evidence of change in a patient's condition. The majority of studies investigating efficacy of Chinese herbal medicine (CHM) have utilized biomedical diagnostic endpoints. For CM clinical diagnostic variables to be incorporated into clinical trial designs, there would need to be evidence that these diagnostic variables are reliable. Previous studies have indicated that the reliability of CM syndrome diagnosis is variable. Little information is known about where the variability stems from--the basic data collection level or the synthesis of diagnostic data, or both. No previous studies have investigated systematically the reliability of all four diagnostic methods used in the CM diagnostic process (Inquiry, Inspection, Auscultation/Olfaction, and Palpation). The objective of this study was to assess the inter-rater reliability of data collected using the four diagnostic methods of CM in Australian patients with knee osteoarthritis (OA), in order to investigate if CM variables could be used with confidence as diagnostic endpoints in a clinical trial investigating the efficacy of a CHM in treating OA. An inter-rater reliability study was conducted as a substudy of a clinical trial investigating the treatment of knee OA with Chinese herbal medicine. Two (2) experienced CM practitioners conducted a CM examination separately, within 2 hours of each other, in 40 participants. A CM assessment form was utilized to record the diagnostic data. Cohen's κ coefficient was used as a measure of the level of agreement between 2 practitioners. There was a relatively good level of agreement for Inquiry and Auscultation variables, and, in general, a low level of agreement for (visual) Inspection and Palpation variables. There was variation in the level of agreement between 2 practitioners on clinical information collected using the Four Diagnostic Methods of a CM examination. Some aspects of CM diagnosis appear to be reliable, while others are not. Based on these results, it was inappropriate to use CM diagnostic variables as diagnostic endpoints in the main study, which was an investigation of efficacy of CHM treatment of knee OA.

  3. Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

    PubMed Central

    Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin

    2016-01-01

    Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196

  4. Method of Testing and Predicting Failures of Electronic Mechanical Systems

    NASA Technical Reports Server (NTRS)

    Iverson, David L.; Patterson-Hine, Frances A.

    1996-01-01

    A method employing a knowledge base of human expertise comprising a reliability model analysis implemented for diagnostic routines is disclosed. The reliability analysis comprises digraph models that determine target events created by hardware failures human actions, and other factors affecting the system operation. The reliability analysis contains a wealth of human expertise information that is used to build automatic diagnostic routines and which provides a knowledge base that can be used to solve other artificial intelligence problems.

  5. The Reliability of Psychiatric Diagnosis Revisited

    PubMed Central

    Rankin, Eric; France, Cheryl; El-Missiry, Ahmed; John, Collin

    2006-01-01

    Background: The authors reviewed the topic of reliability of psychiatric diagnosis from the turn of the 20th century to present. The objectives of this paper are to explore the reasons of unreliability of psychiatric diagnosis and propose ways to improve the reliability of psychiatric diagnosis. Method: The authors reviewed the literature on the concept of reliability of psychiatric diagnosis with emphasis on the impact of interviewing skills, use of diagnostic criteria, and structured interviews on the reliability of psychiatric diagnosis. Results: Causes of diagnostic unreliability are attributed to the patient, the clinician and psychiatric nomenclature. The reliability of psychiatric diagnosis can be enhanced by using diagnostic criteria, defining psychiatric symptoms and structuring the interviews. Conclusions: The authors propose the acronym ‘DR.SED,' which stands for diagnostic criteria, reference definitions, structuring the interview, clinical experience, and data. The authors recommend that clinicians use the DR.SED paradigm to improve the reliability of psychiatric diagnoses. PMID:21103149

  6. Reliability studies of diagnostic methods in Indian traditional Ayurveda medicine: An overview

    PubMed Central

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon; Prasad, Ramjee

    2013-01-01

    Recently, a need to develop supportive new scientific evidence for contemporary Ayurveda has emerged. One of the research objectives is an assessment of the reliability of diagnoses and treatment. Reliability is a quantitative measure of consistency. It is a crucial issue in classification (such as prakriti classification), method development (pulse diagnosis), quality assurance for diagnosis and treatment and in the conduct of clinical studies. Several reliability studies are conducted in western medicine. The investigation of the reliability of traditional Chinese, Japanese and Sasang medicine diagnoses is in the formative stage. However, reliability studies in Ayurveda are in the preliminary stage. In this paper, examples are provided to illustrate relevant concepts of reliability studies of diagnostic methods and their implication in practice, education, and training. An introduction to reliability estimates and different study designs and statistical analysis is given for future studies in Ayurveda. PMID:23930037

  7. Selection and Reporting of Statistical Methods to Assess Reliability of a Diagnostic Test: Conformity to Recommended Methods in a Peer-Reviewed Journal

    PubMed Central

    Park, Ji Eun; Han, Kyunghwa; Sung, Yu Sub; Chung, Mi Sun; Koo, Hyun Jung; Yoon, Hee Mang; Choi, Young Jun; Lee, Seung Soo; Kim, Kyung Won; Shin, Youngbin; An, Suah; Cho, Hyo-Min

    2017-01-01

    Objective To evaluate the frequency and adequacy of statistical analyses in a general radiology journal when reporting a reliability analysis for a diagnostic test. Materials and Methods Sixty-three studies of diagnostic test accuracy (DTA) and 36 studies reporting reliability analyses published in the Korean Journal of Radiology between 2012 and 2016 were analyzed. Studies were judged using the methodological guidelines of the Radiological Society of North America-Quantitative Imaging Biomarkers Alliance (RSNA-QIBA), and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative. DTA studies were evaluated by nine editorial board members of the journal. Reliability studies were evaluated by study reviewers experienced with reliability analysis. Results Thirty-one (49.2%) of the 63 DTA studies did not include a reliability analysis when deemed necessary. Among the 36 reliability studies, proper statistical methods were used in all (5/5) studies dealing with dichotomous/nominal data, 46.7% (7/15) of studies dealing with ordinal data, and 95.2% (20/21) of studies dealing with continuous data. Statistical methods were described in sufficient detail regarding weighted kappa in 28.6% (2/7) of studies and regarding the model and assumptions of intraclass correlation coefficient in 35.3% (6/17) and 29.4% (5/17) of studies, respectively. Reliability parameters were used as if they were agreement parameters in 23.1% (3/13) of studies. Reproducibility and repeatability were used incorrectly in 20% (3/15) of studies. Conclusion Greater attention to the importance of reporting reliability, thorough description of the related statistical methods, efforts not to neglect agreement parameters, and better use of relevant terminology is necessary. PMID:29089821

  8. Development of a diagnostic test set to assess agreement in breast pathology: practical application of the Guidelines for Reporting Reliability and Agreement Studies (GRRAS).

    PubMed

    Oster, Natalia V; Carney, Patricia A; Allison, Kimberly H; Weaver, Donald L; Reisch, Lisa M; Longton, Gary; Onega, Tracy; Pepe, Margaret; Geller, Berta M; Nelson, Heidi D; Ross, Tyler R; Tosteson, Aanna N A; Elmore, Joann G

    2013-02-05

    Diagnostic test sets are a valuable research tool that contributes importantly to the validity and reliability of studies that assess agreement in breast pathology. In order to fully understand the strengths and weaknesses of any agreement and reliability study, however, the methods should be fully reported. In this paper we provide a step-by-step description of the methods used to create four complex test sets for a study of diagnostic agreement among pathologists interpreting breast biopsy specimens. We use the newly developed Guidelines for Reporting Reliability and Agreement Studies (GRRAS) as a basis to report these methods. Breast tissue biopsies were selected from the National Cancer Institute-funded Breast Cancer Surveillance Consortium sites. We used a random sampling stratified according to woman's age (40-49 vs. ≥50), parenchymal breast density (low vs. high) and interpretation of the original pathologist. A 3-member panel of expert breast pathologists first independently interpreted each case using five primary diagnostic categories (non-proliferative changes, proliferative changes without atypia, atypical ductal hyperplasia, ductal carcinoma in situ, and invasive carcinoma). When the experts did not unanimously agree on a case diagnosis a modified Delphi method was used to determine the reference standard consensus diagnosis. The final test cases were stratified and randomly assigned into one of four unique test sets. We found GRRAS recommendations to be very useful in reporting diagnostic test set development and recommend inclusion of two additional criteria: 1) characterizing the study population and 2) describing the methods for reference diagnosis, when applicable.

  9. Improving statistical inference on pathogen densities estimated by quantitative molecular methods: malaria gametocytaemia as a case study.

    PubMed

    Walker, Martin; Basáñez, María-Gloria; Ouédraogo, André Lin; Hermsen, Cornelus; Bousema, Teun; Churcher, Thomas S

    2015-01-16

    Quantitative molecular methods (QMMs) such as quantitative real-time polymerase chain reaction (q-PCR), reverse-transcriptase PCR (qRT-PCR) and quantitative nucleic acid sequence-based amplification (QT-NASBA) are increasingly used to estimate pathogen density in a variety of clinical and epidemiological contexts. These methods are often classified as semi-quantitative, yet estimates of reliability or sensitivity are seldom reported. Here, a statistical framework is developed for assessing the reliability (uncertainty) of pathogen densities estimated using QMMs and the associated diagnostic sensitivity. The method is illustrated with quantification of Plasmodium falciparum gametocytaemia by QT-NASBA. The reliability of pathogen (e.g. gametocyte) densities, and the accompanying diagnostic sensitivity, estimated by two contrasting statistical calibration techniques, are compared; a traditional method and a mixed model Bayesian approach. The latter accounts for statistical dependence of QMM assays run under identical laboratory protocols and permits structural modelling of experimental measurements, allowing precision to vary with pathogen density. Traditional calibration cannot account for inter-assay variability arising from imperfect QMMs and generates estimates of pathogen density that have poor reliability, are variable among assays and inaccurately reflect diagnostic sensitivity. The Bayesian mixed model approach assimilates information from replica QMM assays, improving reliability and inter-assay homogeneity, providing an accurate appraisal of quantitative and diagnostic performance. Bayesian mixed model statistical calibration supersedes traditional techniques in the context of QMM-derived estimates of pathogen density, offering the potential to improve substantially the depth and quality of clinical and epidemiological inference for a wide variety of pathogens.

  10. Tracking Progress in Improving Diagnosis: A Framework for Defining Undesirable Diagnostic Events.

    PubMed

    Olson, Andrew P J; Graber, Mark L; Singh, Hardeep

    2018-01-29

    Diagnostic error is a prevalent, harmful, and costly phenomenon. Multiple national health care and governmental organizations have recently identified the need to improve diagnostic safety as a high priority. A major barrier, however, is the lack of standardized, reliable methods for measuring diagnostic safety. Given the absence of reliable and valid measures for diagnostic errors, we need methods to help establish some type of baseline diagnostic performance across health systems, as well as to enable researchers and health systems to determine the impact of interventions for improving the diagnostic process. Multiple approaches have been suggested but none widely adopted. We propose a new framework for identifying "undesirable diagnostic events" (UDEs) that health systems, professional organizations, and researchers could further define and develop to enable standardized measurement and reporting related to diagnostic safety. We propose an outline for UDEs that identifies both conditions prone to diagnostic error and the contexts of care in which these errors are likely to occur. Refinement and adoption of this framework across health systems can facilitate standardized measurement and reporting of diagnostic safety.

  11. Assessment of the Validity of the Research Diagnostic Criteria for Temporomandibular Disorders: Overview and Methodology

    PubMed Central

    Schiffman, Eric L.; Truelove, Edmond L.; Ohrbach, Richard; Anderson, Gary C.; John, Mike T.; List, Thomas; Look, John O.

    2011-01-01

    AIMS The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. An overview is presented, including Axis I and II methodology and descriptive statistics for the study participant sample. This paper details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. Validity testing for the Axis II biobehavioral instruments was based on previously validated reference standards. METHODS The Axis I reference standards were based on the consensus of 2 criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion exam reliability was also assessed within study sites. RESULTS Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas ≥ 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion exam agreement with reference standards was excellent (k ≥ 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). CONCLUSION The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods. PMID:20213028

  12. Cervical vertebral maturation method and mandibular growth peak: a longitudinal study of diagnostic reliability.

    PubMed

    Perinetti, Giuseppe; Primozic, Jasmina; Sharma, Bhavna; Cioffi, Iacopo; Contardo, Luca

    2018-03-28

    The capability of the cervical vertebral maturation (CVM) method in the identification of the mandibular growth peak on an individual basis remains undetermined. The diagnostic reliability of the six-stage CVM method in the identification of the mandibular growth peak was thus investigated. From the files of the Oregon and Burlington Growth Studies (data obtained between early 1950s and middle 1970s), 50 subjects (26 females, 24 males) with at least seven annual lateral cephalograms taken from 9 to 16 years were identified. Cervical vertebral maturation was assessed according to the CVM code staging system, and mandibular growth was defined as annual increments in Co-Gn distance. A diagnostic reliability analysis was carried out to establish the capability of the circumpubertal CVM stages 2, 3, and 4 in the identification of the imminent mandibular growth peak. Variable durations of each of the CVM stages 2, 3, and 4 were seen. The overall diagnostic accuracy values for the CVM stages 2, 3, and 4 were 0.70, 0.76, and 0.77, respectively. These low values appeared to be due to false positive cases. Secular trends in conjunction with the use of a discrete staging system. In most of the Burlington Growth Study sample, the lateral head film at age 15 was missing. None of the CVM stages 2, 3, and 4 reached a satisfactorily diagnostic reliability in the identification of imminent mandibular growth peak.

  13. Reliability and Validity of a Procedure To Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    Preliminary psychometric data assessing the reliability and validity of a method used to measure the diagnostic reasoning and problem-solving skills of predoctoral students in orthodontia are described. The measurement approach consisted of sets of patient demographic data and dental photos and x-rays, accompanied by a set of 33 multiple-choice…

  14. Requirements for diagnosis of malaria at different levels of the laboratory network in Africa.

    PubMed

    Long, Earl G

    2009-06-01

    The rapid increase of resistance to cheap, reliable antimalarials, the increasing cost of effective drugs, and the low specificity of clinical diagnosis has increased the need for more reliable diagnostic methods for malaria. The most commonly used and most reliable remains microscopic examination of stained blood smears, but this technique requires skilled personnel, precision instruments, and ideally a source of electricity. Microscopy has the advantage of enabling the examiner to identify the species, stage, and density of an infection. An alternative to microscopy is the rapid diagnostic test (RDT), which uses a labeled monoclonal antibody to detect circulating parasitic antigens. This test is most commonly used to detect Plasmodium falciparum infections and is available in a plastic cassette format. Both microscopy and RDTs should be available at all levels of laboratory service in endemic areas, but in peripheral laboratories with minimally trained staff, the RDT may be a more practical diagnostic method.

  15. The Research Diagnostic Criteria for Temporomandibular Disorders. I: overview and methodology for assessment of validity.

    PubMed

    Schiffman, Eric L; Truelove, Edmond L; Ohrbach, Richard; Anderson, Gary C; John, Mike T; List, Thomas; Look, John O

    2010-01-01

    The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. The aim of this article is to provide an overview of the project's methodology, descriptive statistics, and data for the study participant sample. This article also details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. The Axis I reference standards were based on the consensus of two criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion examination reliability was also assessed within study sites. Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas > or = 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion examiner agreement with reference standards was excellent (k > or = 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods.

  16. A closer look at diagnosis in clinical dental practice: part 1. Reliability, validity, specificity and sensitivity of diagnostic procedures.

    PubMed

    Pretty, Iain A; Maupomé, Gerardo

    2004-04-01

    Dentists are involved in diagnosing disease in every aspect of their clinical practice. A range of tests, systems, guides and equipment--which can be generally referred to as diagnostic procedures--are available to aid in diagnostic decision making. In this era of evidence-based dentistry, and given the increasing demand for diagnostic accuracy and properly targeted health care, it is important to assess the value of such diagnostic procedures. Doing so allows dentists to weight appropriately the information these procedures supply, to purchase new equipment if it proves more reliable than existing equipment or even to discard a commonly used procedure if it is shown to be unreliable. This article, the first in a 6-part series, defines several concepts used to express the usefulness of diagnostic procedures, including reliability and validity, and describes some of their operating characteristics (statistical measures of performance), in particular, specificity and sensitivity. Subsequent articles in the series will discuss the value of diagnostic procedures used in daily dental practice and will compare today's most innovative procedures with established methods.

  17. Turfgrass diagnostics and new, advanced technologies

    USDA-ARS?s Scientific Manuscript database

    Strategies for sustainable, integrated disease management start with reliable pathogen identification. Conventional identification methods such as disease symptomology, host association, morphology and biochemical tests are still key diagnostic indicators for many phytopathogens; however, nucleic ac...

  18. The Arthroscopic Surgical Skill Evaluation Tool (ASSET).

    PubMed

    Koehler, Ryan J; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Bramen, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J; Nicandri, Gregg T

    2013-06-01

    Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice; however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability when used to assess the technical ability of surgeons performing diagnostic knee arthroscopic surgery on cadaveric specimens. Cross-sectional study; Level of evidence, 3. Content validity was determined by a group of 7 experts using the Delphi method. Intra-articular performance of a right and left diagnostic knee arthroscopic procedure was recorded for 28 residents and 2 sports medicine fellowship-trained attending surgeons. Surgeon performance was assessed by 2 blinded raters using the ASSET. Concurrent criterion-oriented validity, interrater reliability, and test-retest reliability were evaluated. Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in the total ASSET score (P < .05) between novice, intermediate, and advanced experience groups were identified. Interrater reliability: The ASSET scores assigned by each rater were strongly correlated (r = 0.91, P < .01), and the intraclass correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: There was a significant correlation between ASSET scores for both procedures attempted by each surgeon (r = 0.79, P < .01). The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopic surgery in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live operating room and other simulated environments.

  19. [Methods of statistical analysis in differential diagnostics of the degree of brain glioma anaplasia during preoperative stage].

    PubMed

    Glavatskiĭ, A Ia; Guzhovskaia, N V; Lysenko, S N; Kulik, A V

    2005-12-01

    The authors proposed a possible preoperative diagnostics of the degree of supratentorial brain gliom anaplasia using statistical analysis methods. It relies on a complex examination of 934 patients with I-IV degree anaplasias, which had been treated in the Institute of Neurosurgery from 1990 to 2004. The use of statistical analysis methods for differential diagnostics of the degree of brain gliom anaplasia may optimize a diagnostic algorithm, increase reliability of obtained data and in some cases avoid carrying out irrational operative intrusions. Clinically important signs for the use of statistical analysis methods directed to preoperative diagnostics of brain gliom anaplasia have been defined

  20. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective

    PubMed Central

    Shterenshis, Michael

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes. PMID:29138741

  1. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective.

    PubMed

    Shterenshis, Michael

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes.

  2. Reliability of criteria for borderline personality disorder: a comparison of DSM-III and the Diagnostic Interview for Borderline Patients.

    PubMed

    Frances, A; Clarkin, J F; Gilmore, M; Hurt, S W; Brown, R

    1984-09-01

    The authors compared the reliability of two methods of distinguishing borderline personality disorder--DSM-III and the Diagnostic Interview for Borderline Patients. The reference group, outpatients with other personality disorders and without major axis I pathology, was more difficult to distinguish from the patients with borderline personality disorder than such groups used in previous samples. The sensitivity and specificity of the Diagnostic Interview for Borderline Patients were calculated, with DSM-III used as a criterion. The findings confirm considerable overlap between borderline and schizotypal personality disorders, more impairment in functioning in borderline patients than in those with other personality disorders, and the high reliability with which borderline personality disorder can be diagnosed.

  3. The Arthroscopic Surgical Skill Evaluation Tool (ASSET)

    PubMed Central

    Koehler, Ryan J.; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J.; Nicandri, Gregg T.

    2014-01-01

    Background Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. Hypothesis The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability, when used to assess the technical ability of surgeons performing diagnostic knee arthroscopy on cadaveric specimens. Study Design Cross-sectional study; Level of evidence, 3 Methods Content validity was determined by a group of seven experts using a Delphi process. Intra-articular performance of a right and left diagnostic knee arthroscopy was recorded for twenty-eight residents and two sports medicine fellowship trained attending surgeons. Subject performance was assessed by two blinded raters using the ASSET. Concurrent criterion-oriented validity, inter-rater reliability, and test-retest reliability were evaluated. Results Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in total ASSET score (p<0.05) between novice, intermediate, and advanced experience groups were identified. Inter-rater reliability: The ASSET scores assigned by each rater were strongly correlated (r=0.91, p <0.01) and the intra-class correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: there was a significant correlation between ASSET scores for both procedures attempted by each individual (r = 0.79, p<0.01). Conclusion The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopy in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live OR and other simulated environments. PMID:23548808

  4. Examinations of electron temperature calculation methods in Thomson scattering diagnostics.

    PubMed

    Oh, Seungtae; Lee, Jong Ha; Wi, Hanmin

    2012-10-01

    Electron temperature from Thomson scattering diagnostic is derived through indirect calculation based on theoretical model. χ-square test is commonly used in the calculation, and the reliability of the calculation method highly depends on the noise level of input signals. In the simulations, noise effects of the χ-square test are examined and scale factor test is proposed as an alternative method.

  5. Some Clinical Diagnoses are More Reliable than Others

    DTIC Science & Technology

    1989-03-29

    a more reliable measure than diagnostic type (e.g., schizophrenia versus personality disor- der). Diagnostic type, in turn, was a more reliable...measure than diagnostic subtype (e.g., chronic catatonic schizophrenic). And, certain diagnostic types aild Suutypes wete consistently more reliable across...diagnoses included thie following diagnostic typesý: 1) organic psychoses, 2) schizophrenia , 3) affective psychoses, 4) pala- 4 noia, 5) other

  6. A Review of Transmission Diagnostics Research at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Zakajsek, James J.

    1994-01-01

    This paper presents a summary of the transmission diagnostics research work conducted at NASA Lewis Research Center over the last four years. In 1990, the Transmission Health and Usage Monitoring Research Team at NASA Lewis conducted a survey to determine the critical needs of the diagnostics community. Survey results indicated that experimental verification of gear and bearing fault detection methods, improved fault detection in planetary systems, and damage magnitude assessment and prognostics research were all critical to a highly reliable health and usage monitoring system. In response to this, a variety of transmission fault detection methods were applied to experimentally obtained fatigue data. Failure modes of the fatigue data include a variety of gear pitting failures, tooth wear, tooth fracture, and bearing spalling failures. Overall results indicate that, of the gear fault detection techniques, no one method can successfully detect all possible failure modes. The more successful methods need to be integrated into a single more reliable detection technique. A recently developed method, NA4, in addition to being one of the more successful gear fault detection methods, was also found to exhibit damage magnitude estimation capabilities.

  7. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    PubMed

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  8. Reliability and validity of a Chinese version of the Diagnostic Interview for Borderlines-Revised.

    PubMed

    Wang, Lanlan; Yuan, Chenmei; Qiu, Jianying; Gunderson, John; Zhang, Min; Jiang, Kaida; Leung, Freedom; Zhong, Jie; Xiao, Zeping

    2014-09-01

    Borderline personality disorder (BPD) is the most studied of the axis II disorders. One of the most widely used diagnostic instruments is the Diagnostic Interview for Borderline Patients-Revised (DIB-R). The aim of this study was to test the reliability and validity of DIB-R for use in the Chinese culture. The reliability and validity of the DIB-R Chinese version were assessed in a sample of 236 outpatients with a probable BPD diagnosis. The Structured Clinical Interview for DSM-IV Personality Disorders (SCID-II) was used as a standard. Test-retest reliability was tested six months later with 20 patients, and inter-rater reliability was tested on 32 patients. The Chinese version of the DIB-R showed good internal global consistency (Cronbach's α of 0.916), good test-retest reliability (Pearson correlation of 0.704), good inter-rater reliability (intra-class correlation coefficient of 0.892 and kappa of 0.861). When compared with the DSM-IV diagnosis as measured by the SCID-II, the DIB-R showed relatively good sensitivity (0.768) and specificity (0.891) at the cutoff of 7, moderate diagnostic convergence (kappa of 0.631), as well as good discriminating validity. The Chinese version of the DIB-R has good psychometric properties, which renders it a valuable method for examining the presence, the severity, and component phenotypes of BPD in Chinese samples. © 2013 Wiley Publishing Asia Pty Ltd.

  9. The system of technical diagnostics of the industrial safety information network

    NASA Astrophysics Data System (ADS)

    Repp, P. V.

    2017-01-01

    This research is devoted to problems of safety of the industrial information network. Basic sub-networks, ensuring reliable operation of the elements of the industrial Automatic Process Control System, were identified. The core tasks of technical diagnostics of industrial information safety were presented. The structure of the technical diagnostics system of the information safety was proposed. It includes two parts: a generator of cyber-attacks and the virtual model of the enterprise information network. The virtual model was obtained by scanning a real enterprise network. A new classification of cyber-attacks was proposed. This classification enables one to design an efficient generator of cyber-attacks sets for testing the virtual modes of the industrial information network. The numerical method of the Monte Carlo (with LPτ - sequences of Sobol), and Markov chain was considered as the design method for the cyber-attacks generation algorithm. The proposed system also includes a diagnostic analyzer, performing expert functions. As an integrative quantitative indicator of the network reliability the stability factor (Kstab) was selected. This factor is determined by the weight of sets of cyber-attacks, identifying the vulnerability of the network. The weight depends on the frequency and complexity of cyber-attacks, the degree of damage, complexity of remediation. The proposed Kstab is an effective integral quantitative measure of the information network reliability.

  10. Experimental application of OMA solutions on the model of industrial structure

    NASA Astrophysics Data System (ADS)

    Mironov, A.; Mironovs, D.

    2017-10-01

    It is very important and sometimes even vital to maintain reliability of industrial structures. High quality control during production and structural health monitoring (SHM) in exploitation provides reliable functioning of large, massive and remote structures, like wind generators, pipelines, power line posts, etc. This paper introduces a complex of technological and methodical solutions for SHM and diagnostics of industrial structures, including those that are actuated by periodic forces. Solutions were verified on a wind generator scaled model with integrated system of piezo-film deformation sensors. Simultaneous and multi-patch Operational Modal Analysis (OMA) approaches were implemented as methodical means for structural diagnostics and monitoring. Specially designed data processing algorithms provide objective evaluation of structural state modification.

  11. WHO Study on the reliability and validity of the alcohol and drug use disorder instruments: overview of methods and results.

    PubMed

    Ustün, B; Compton, W; Mager, D; Babor, T; Baiyewu, O; Chatterji, S; Cottler, L; Göğüş, A; Mavreas, V; Peters, L; Pull, C; Saunders, J; Smeets, R; Stipec, M R; Vrasti, R; Hasin, D; Room, R; Van den Brink, W; Regier, D; Blaine, J; Grant, B F; Sartorius, N

    1997-09-25

    The WHO Study on the reliability and validity of the alcohol and drug use disorder instruments in an international study which has taken place in centres in ten countries, aiming to test the reliability and validity of three diagnostic instruments for alcohol and drug use disorders: the Composite International Diagnostic Interview (CIDI), the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) and a special version of the Alcohol Use Disorder and Associated Disabilities Interview schedule-alcohol/drug-revised (AUDADIS-ADR). The purpose of the reliability and validity (R&V) study is to further develop the alcohol and drug sections of these instruments so that a range of substance-related diagnoses can be made in a systematic, consistent, and reliable way. The study focuses on new criteria proposed in the tenth revision of the International Classification of Diseases (ICD-10) and the fourth revision of the diagnostic and statistical manual of mental disorders (DSM-IV) for dependence, harmful use and abuse categories for alcohol and psychoactive substance use disorders. A systematic study including a scientifically rigorous measure of reliability (i.e. 1 week test-retest reliability) and validity (i.e. comparison between clinical and non-clinical measures) has been undertaken. Results have yielded useful information on reliability and validity of these instruments at diagnosis, criteria and question level. Overall the diagnostic concordance coefficients (kappa, kappa) were very good for dependence disorders (0.7-0.9), but were somewhat lower for the abuse and harmful use categories. The comparisons among instruments and independent clinical evaluations and debriefing interviews gave important information about possible sources of unreliability, and provided useful clues on the applicability and consistency of nosological concepts across cultures.

  12. The development of a quality appraisal tool for studies of diagnostic reliability (QAREL).

    PubMed

    Lucas, Nicholas P; Macaskill, Petra; Irwig, Les; Bogduk, Nikolai

    2010-08-01

    In systematic reviews of the reliability of diagnostic tests, no quality assessment tool has been used consistently. The aim of this study was to develop a specific quality appraisal tool for studies of diagnostic reliability. Key principles for the quality of studies of diagnostic reliability were identified with reference to epidemiologic principles, existing quality appraisal checklists, and the Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) resources. Specific items that encompassed each of the principles were developed. Experts in diagnostic research provided feedback on the items that were to form the appraisal tool. This process was iterative and continued until consensus among experts was reached. The Quality Appraisal of Reliability Studies (QAREL) checklist includes 11 items that explore seven principles. Items cover the spectrum of subjects, spectrum of examiners, examiner blinding, order effects of examination, suitability of the time interval among repeated measurements, appropriate test application and interpretation, and appropriate statistical analysis. QAREL has been developed as a specific quality appraisal tool for studies of diagnostic reliability. The reliability of this tool in different contexts needs to be evaluated. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  13. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    PubMed

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  14. Lithium Battery Transient Response as a Diagnostic Tool

    NASA Astrophysics Data System (ADS)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  15. Reliability of Growth Indicators and Efficiency of Functional Treatment for Skeletal Class II Malocclusion: Current Evidence and Controversies.

    PubMed

    Perinetti, Giuseppe; Contardo, Luca

    2017-01-01

    Current evidence on the reliability of growth indicators in the identification of the pubertal growth spurt and efficiency of functional treatment for skeletal Class II malocclusion, the timing of which relies on such indicators, is highly controversial. Regarding growth indicators, the hand and wrist (including the sole middle phalanx of the third finger) maturation method and the standing height recording appear to be most reliable. Other methods are subjected to controversies or were showed to be unreliable. Main sources of controversies include use of single stages instead of ossification events and diagnostic reliability conjecturally based on correlation analyses. Regarding evidence on the efficiency of functional treatment, when treated during the pubertal growth spurt, more favorable response is seen in skeletal Class II patients even though large individual responsiveness remains. Main sources of controversies include design of clinical trials, definition of Class II malocclusion, and lack of inclusion of skeletal maturity among the prognostic factors. While no growth indicator may be considered to have a full diagnostic reliability in the identification of the pubertal growth spurt, their use may still be recommended for increasing efficiency of functional treatment for skeletal Class II malocclusion.

  16. Reliability of Growth Indicators and Efficiency of Functional Treatment for Skeletal Class II Malocclusion: Current Evidence and Controversies

    PubMed Central

    2017-01-01

    Current evidence on the reliability of growth indicators in the identification of the pubertal growth spurt and efficiency of functional treatment for skeletal Class II malocclusion, the timing of which relies on such indicators, is highly controversial. Regarding growth indicators, the hand and wrist (including the sole middle phalanx of the third finger) maturation method and the standing height recording appear to be most reliable. Other methods are subjected to controversies or were showed to be unreliable. Main sources of controversies include use of single stages instead of ossification events and diagnostic reliability conjecturally based on correlation analyses. Regarding evidence on the efficiency of functional treatment, when treated during the pubertal growth spurt, more favorable response is seen in skeletal Class II patients even though large individual responsiveness remains. Main sources of controversies include design of clinical trials, definition of Class II malocclusion, and lack of inclusion of skeletal maturity among the prognostic factors. While no growth indicator may be considered to have a full diagnostic reliability in the identification of the pubertal growth spurt, their use may still be recommended for increasing efficiency of functional treatment for skeletal Class II malocclusion. PMID:28168195

  17. Interrater reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression - A systematic review and meta-analysis.

    PubMed

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2016-10-01

    Schizoaffective disorder is a common diagnosis in clinical practice but its nosological status has been subject to debate ever since it was conceptualized. Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater reliability. Evidence based on systematic review and meta-analysis methods, however, is lacking. Using a highly sensitive literature search in Medline, Embase, and PsycInfo we identified studies measuring the interrater reliability of schizoaffective disorder in comparison to schizophrenia, bipolar disorder, and unipolar disorder. Out of 4126 records screened we included 25 studies reporting on 7912 patients diagnosed by different raters. The interrater reliability of schizoaffective disorder was moderate (meta-analytic estimate of Cohen's kappa 0.57 [95% CI: 0.41-0.73]), and substantially lower than that of its main differential diagnoses (difference in kappa between 0.22 and 0.19). Although there was considerable heterogeneity, analyses revealed that the interrater reliability of schizoaffective disorder was consistently lower in the overwhelming majority of studies. The results remained robust in subgroup and sensitivity analyses (e.g., diagnostic manual used) as well as in meta-regressions (e.g., publication year) and analyses of publication bias. Clinically, the results highlight the particular importance of diagnostic re-evaluation in patients diagnosed with schizoaffective disorder. They also quantify a widely held clinical impression of lower interrater reliability and agree with earlier meta-analysis reporting low test-retest reliability. Copyright © 2016. Published by Elsevier B.V.

  18. Assessment of Semi-Structured Clinical Interview for Mobile Phone Addiction Disorder

    PubMed Central

    Alavi, Seyyed Salman; Jannatifard, Fereshteh; Mohammadi Kalhori, Soroush; Sepahbodi, Ghazal; BabaReisi, Mohammad; Sajedi, Sahar; Farshchi, Mojtaba; KhodaKarami, Rasul; Hatami Kasvaee, Vahid

    2016-01-01

    Objective: The Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) classified mobile phone addiction disorder under “impulse control disorder not elsewhere classified”. This study surveyed the diagnostic criteria of DSM-IV-TR for the diagnosis of mobile phone addiction in correspondence with Iranian society and culture. Method: Two hundred fifty students of Tehran universities were entered into this descriptive-analytical and cross-sectional study. Quota sampling method was used. At first, semi- structured clinical interview (based on DSM-IV-TR) was performed for all the cases, and another specialist reevaluated the interviews. Data were analyzed using content validity, inter-scorer reliability (Kappa coefficient) and test-retest via SPSS18 software. Results: The content validity of the semi- structured clinical interview matched the DSM–IV-TR criteria for behavioral addiction. Moreover, their content was appropriate, and two items, including “SMS pathological use” and “High monthly cost of using the mobile phone” were added to promote its validity. Internal reliability (Kappa) and test–retest reliability were 0.55 and r = 0.4 (p<0. 01) respectively. Conclusion: The results of this study revealed that semi- structured diagnostic criteria of DSM-IV-TR are valid and reliable for diagnosing mobile phone addiction, and this instrument is an effective tool to diagnose this disorder. PMID:27437008

  19. Reliability, Validity, and Classification Accuracy of the DSM-5 Diagnostic Criteria for Gambling Disorder and Comparison to DSM-IV.

    PubMed

    Stinchfield, Randy; McCready, John; Turner, Nigel E; Jimenez-Murcia, Susana; Petry, Nancy M; Grant, Jon; Welte, John; Chapman, Heather; Winters, Ken C

    2016-09-01

    The DSM-5 was published in 2013 and it included two substantive revisions for gambling disorder (GD). These changes are the reduction in the threshold from five to four criteria and elimination of the illegal activities criterion. The purpose of this study was to twofold. First, to assess the reliability, validity and classification accuracy of the DSM-5 diagnostic criteria for GD. Second, to compare the DSM-5-DSM-IV on reliability, validity, and classification accuracy, including an examination of the effect of the elimination of the illegal acts criterion on diagnostic accuracy. To compare DSM-5 and DSM-IV, eight datasets from three different countries (Canada, USA, and Spain; total N = 3247) were used. All datasets were based on similar research methods. Participants were recruited from outpatient gambling treatment services to represent the group with a GD and from the community to represent the group without a GD. All participants were administered a standardized measure of diagnostic criteria. The DSM-5 yielded satisfactory reliability, validity and classification accuracy. In comparing the DSM-5 to the DSM-IV, most comparisons of reliability, validity and classification accuracy showed more similarities than differences. There was evidence of modest improvements in classification accuracy for DSM-5 over DSM-IV, particularly in reduction of false negative errors. This reduction in false negative errors was largely a function of lowering the cut score from five to four and this revision is an improvement over DSM-IV. From a statistical standpoint, eliminating the illegal acts criterion did not make a significant impact on diagnostic accuracy. From a clinical standpoint, illegal acts can still be addressed in the context of the DSM-5 criterion of lying to others.

  20. Polish Adult Reading Test (PART) - construction of Polish test for estimating the level of premorbid intelligence in schizophrenia.

    PubMed

    Karakuła-Juchnowicz, Hanna; Stecka, Mariola

    2017-08-29

    In view of unavailability in Poland of the standardized methods to measure PIQ, the aim of the work was to develop a Polish test to assess the premorbid level of intelligence - PART(Polish AdultReading Test) and to measureits psychometric properties, such as validity, reliability as well as standardization in the group of schizophrenia patients. The principles of PART construction were based on the idea of popular worldwide National Adult Reading Test by Hazel Nelson. The research comprised a group of 122 subjects (65 schizophrenia patients and 57 healthy people), aged 18-60 years, matched for age and gender. PART appears to be a method with high internal consistency and reliability measured by test-retest, inter-rater reliability, and the method with acceptable diagnostic and prognostic validity. The standardized procedures of PART have been investigated and described. Considering the psychometric values of PART and a short time of its performance, the test may be a useful diagnostic instrument in the assessment of premorbid level of intelligence in a group of schizophrenic patients.

  1. An efficient method for unfolding kinetic pressure driven VISAR data

    DOE PAGES

    Mark Harry Hess; Peterson, Kyle; Harvey-Thompson, Adam James

    2015-08-18

    Velocity Interferometer System for Any Reflector (VISAR) [Barker and Hollenbach, J. Appl. Phys.43, 4669 (1972)] is a well-known diagnostic that is employed on many shock physics and pulsed-power experiments. With the VISAR diagnostic, the velocity on the surface of any metal flyer can be found. For most experiments employing VISAR, either a kinetic pressure [Grady, Mech. Mater.29, 181 (1998)] or a magnetic pressure [Lemkeet al., Intl J. Impact Eng.38, 480 (2011)] drives the motion of the flyer. Moreover, reliable prediction of the time-dependent pressure is often a critical component to understanding the physics of these experiments. Although VISAR can provide amore » precise measurement of a flyer’s surface velocity, the real challenge of this diagnostic implementation is using this velocity to unfold the time-dependent pressure. As a result, the purpose of this paper is to elucidate a new method for quickly and reliably unfolding VISAR data.« less

  2. Orthopoxvirus detection in environmental specimens during suspected bioterror attacks: inhibitory influences of common household products.

    PubMed

    Kurth, Andreas; Achenbach, John; Miller, Liljia; Mackay, Ian M; Pauli, Georg; Nitsche, Andreas

    2008-01-01

    After terrorists attacked the United States in 2001, the appearance of letters and other objects containing powdery substances with unknown potentials for biological threat focused attention on the speed, sensitivity, and reliability of diagnostic methods. This study summarizes the abilities and limitations of real-time PCR, electron microscopy (EM), and virus isolation when used to detect potential bioweapons. In particular, we investigated the inhibitory influences of different common household products present in environmental specimens on PCR yield, EM detection, and virus isolation. We used vaccinia virus as a model for orthopoxviruses by spiking it into specimens. In the second part of the study, we describe modifications of diagnostic methods to overcome inhibitory effects. A variety of PCR amplification enhancers, DNA extraction protocols, and applications of internal controls were evaluated to improve diagnostic simplicity, speed, and reliability. As a result, we strongly recommend using at least two different frontline techniques in parallel, e.g., EM and PCR. A positive result obtained by any one of these techniques should be followed by a biological method to confirm the putative diagnosis. Confirmatory methods include virus isolation followed by an agent-specific immunofluorescence assay to confirm the presence of replication-competent particles.

  3. Orthopoxvirus Detection in Environmental Specimens during Suspected Bioterror Attacks: Inhibitory Influences of Common Household Products▿

    PubMed Central

    Kurth, Andreas; Achenbach, John; Miller, Liljia; Mackay, Ian M.; Pauli, Georg; Nitsche, Andreas

    2008-01-01

    After terrorists attacked the United States in 2001, the appearance of letters and other objects containing powdery substances with unknown potentials for biological threat focused attention on the speed, sensitivity, and reliability of diagnostic methods. This study summarizes the abilities and limitations of real-time PCR, electron microscopy (EM), and virus isolation when used to detect potential bioweapons. In particular, we investigated the inhibitory influences of different common household products present in environmental specimens on PCR yield, EM detection, and virus isolation. We used vaccinia virus as a model for orthopoxviruses by spiking it into specimens. In the second part of the study, we describe modifications of diagnostic methods to overcome inhibitory effects. A variety of PCR amplification enhancers, DNA extraction protocols, and applications of internal controls were evaluated to improve diagnostic simplicity, speed, and reliability. As a result, we strongly recommend using at least two different frontline techniques in parallel, e.g., EM and PCR. A positive result obtained by any one of these techniques should be followed by a biological method to confirm the putative diagnosis. Confirmatory methods include virus isolation followed by an agent-specific immunofluorescence assay to confirm the presence of replication-competent particles. PMID:17965204

  4. Reduction of bias and variance for evaluation of computer-aided diagnostic schemes.

    PubMed

    Li, Qiang; Doi, Kunio

    2006-04-01

    Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in detecting various lesions in medical images. In addition to the development, an equally important problem is the reliable evaluation of the performance levels of various CAD schemes. It is good to see that more and more investigators are employing more reliable evaluation methods such as leave-one-out and cross validation, instead of less reliable methods such as resubstitution, for assessing their CAD schemes. However, the common applications of leave-one-out and cross-validation evaluation methods do not necessarily imply that the estimated performance levels are accurate and precise. Pitfalls often occur in the use of leave-one-out and cross-validation evaluation methods, and they lead to unreliable estimation of performance levels. In this study, we first identified a number of typical pitfalls for the evaluation of CAD schemes, and conducted a Monte Carlo simulation experiment for each of the pitfalls to demonstrate quantitatively the extent of bias and/or variance caused by the pitfall. Our experimental results indicate that considerable bias and variance may exist in the estimated performance levels of CAD schemes if one employs various flawed leave-one-out and cross-validation evaluation methods. In addition, for promoting and utilizing a high standard for reliable evaluation of CAD schemes, we attempt to make recommendations, whenever possible, for overcoming these pitfalls. We believe that, with the recommended evaluation methods, we can considerably reduce the bias and variance in the estimated performance levels of CAD schemes.

  5. Test-retest reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression--a systematic review and meta-analysis.

    PubMed

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2015-11-01

    Schizoaffective disorder is a frequent diagnosis, and its reliability is subject to ongoing discussion. We compared the diagnostic reliability of schizoaffective disorder with its main differential diagnoses. We systematically searched Medline, Embase, and PsycInfo for all studies on the test-retest reliability of the diagnosis of schizoaffective disorder as compared with schizophrenia, bipolar disorder, and unipolar depression. We used meta-analytic methods to describe and compare Cohen's kappa as well as positive and negative agreement. In addition, multiple pre-specified and post hoc subgroup and sensitivity analyses were carried out. Out of 4,415 studies screened, 49 studies were included. Test-retest reliability of schizoaffective disorder was consistently lower than that of schizophrenia (in 39 out of 42 studies), bipolar disorder (27/33), and unipolar depression (29/35). The mean difference in kappa between schizoaffective disorder and the other diagnoses was approximately 0.2, and mean Cohen's kappa for schizoaffective disorder was 0.50 (95% confidence interval: 0.40-0.59). While findings were unequivocal and homogeneous for schizoaffective disorder's diagnostic reliability relative to its three main differential diagnoses (dichotomous: smaller versus larger), heterogeneity was substantial for continuous measures, even after subgroup and sensitivity analyses. In clinical practice and research, schizoaffective disorder's comparatively low diagnostic reliability should lead to increased efforts to correctly diagnose the disorder. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. The London field trial for hoarding disorder.

    PubMed

    Mataix-Cols, D; Billotti, D; Fernández de la Cruz, L; Nordsletten, A E

    2013-04-01

    A new diagnostic category, hoarding disorder (HD), has been proposed for inclusion in DSM-5. This study field-tested the validity, reliability and perceived acceptability of the proposed diagnostic criteria for HD. Method Fifty unselected individuals with prominent hoarding behavior and 20 unselected, self-defined 'collectors' participated in thorough psychiatric assessments, involving home visits whenever possible. A semi-structured interview based on the proposed diagnostic criteria for HD was administered and scored by two independent raters. 'True' diagnoses were made by consensus according to the best-estimate diagnosis procedure. The percentage of true positive HD cases (sensitivity) and true negative HD cases (specificity) was calculated, along with inter-rater reliability for the diagnosis and each criterion. Participants were asked about their perceptions of the acceptability, utility and stigma associated with the new diagnosis. Twenty-nine (58%) of the hoarding individuals and none of the collectors fulfilled diagnostic criteria for HD. The sensitivity, specificity and inter-rater reliability of the diagnosis, and of each individual criterion and the specifiers, were excellent. Most participants with HD (96%) felt that creating a new disorder would be very or somewhat acceptable, useful (96%) and not too stigmatizing (59%). The proposed HD criteria are valid, reliable and perceived as acceptable and useful by the sufferers. Crucially, they seem to be sufficiently conservative and unlikely to overpathologize normative behavior. Minor changes in the wording of the criteria are suggested.

  7. GUI Type Fault Diagnostic Program for a Turboshaft Engine Using Fuzzy and Neural Networks

    NASA Astrophysics Data System (ADS)

    Kong, Changduk; Koo, Youngju

    2011-04-01

    The helicopter to be operated in a severe flight environmental condition must have a very reliable propulsion system. On-line condition monitoring and fault detection of the engine can promote reliability and availability of the helicopter propulsion system. A hybrid health monitoring program using Fuzzy Logic and Neural Network Algorithms can be proposed. In this hybrid method, the Fuzzy Logic identifies easily the faulted components from engine measuring parameter changes, and the Neural Networks can quantify accurately its identified faults. In order to use effectively the fault diagnostic system, a GUI (Graphical User Interface) type program is newly proposed. This program is composed of the real time monitoring part, the engine condition monitoring part and the fault diagnostic part. The real time monitoring part can display measuring parameters of the study turboshaft engine such as power turbine inlet temperature, exhaust gas temperature, fuel flow, torque and gas generator speed. The engine condition monitoring part can evaluate the engine condition through comparison between monitoring performance parameters the base performance parameters analyzed by the base performance analysis program using look-up tables. The fault diagnostic part can identify and quantify the single faults the multiple faults from the monitoring parameters using hybrid method.

  8. Influence of environmental tobacco smoke on morphology and functions of cardiovascular system assessed using diagnostic imaging.

    PubMed

    Gać, Paweł; Poręba, Małgorzata; Pawlas, Krystyna; Sobieszczańska, Małgorzata; Poręba, Rafał

    Exposure to tobacco smoke is a significant problem of environmental medicine. Tobacco smoke contains over one thousand identified chemicals including numerous toxicants. Cardiovascular system diseases are the major cause of general mortality. The recent development of diagnostic imaging provided methods which enable faster and more precise diagnosis of numerous diseases, also those of cardiovascular system. This paper reviews the most significant scientific research concerning relationship between environmental exposure to tobacco smoke and the morphology and function of cardiovascular system carried out using diagnostic imaging methods, i.e. ultrasonography, angiography, computed tomography and magnetic resonance imaging. In the forthcoming future, the studies using current diagnostic imaging methods should contribute to the reliable documentation, followed by the wide-spreading knowledge of the harmful impact of the environmental tobacco smoke exposure on the cardiovascular system.

  9. Calibrations of the LHD Thomson scattering system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, I., E-mail: yamadai@nifs.ac.jp; Funaba, H.; Yasuhara, R.

    2016-11-15

    The Thomson scattering diagnostic systems are widely used for the measurements of absolute local electron temperatures and densities of fusion plasmas. In order to obtain accurate and reliable temperature and density data, careful calibrations of the system are required. We have tried several calibration methods since the second LHD experiment campaign in 1998. We summarize the current status of the calibration methods for the electron temperature and density measurements by the LHD Thomson scattering diagnostic system. Future plans are briefly discussed.

  10. Calibrations of the LHD Thomson scattering system.

    PubMed

    Yamada, I; Funaba, H; Yasuhara, R; Hayashi, H; Kenmochi, N; Minami, T; Yoshikawa, M; Ohta, K; Lee, J H; Lee, S H

    2016-11-01

    The Thomson scattering diagnostic systems are widely used for the measurements of absolute local electron temperatures and densities of fusion plasmas. In order to obtain accurate and reliable temperature and density data, careful calibrations of the system are required. We have tried several calibration methods since the second LHD experiment campaign in 1998. We summarize the current status of the calibration methods for the electron temperature and density measurements by the LHD Thomson scattering diagnostic system. Future plans are briefly discussed.

  11. Test-Retest Reliability of the Preschool Age Psychiatric Assessment (PAPA)

    ERIC Educational Resources Information Center

    Egger, Helen Link; Erkanli, Alaattin; Keeler, Gordon; Potts, Edward; Walter, Barbara Keith; Angold, Adrian

    2006-01-01

    Objective: To examine the test-retest reliability of a new interviewer-based psychiatric diagnostic measure (the Preschool Age Psychiatric Assessment) for use with parents of preschoolers 2 to 5 years old. Method: A total of 1,073 parents of children attending a large pediatric clinic completed the Child Behavior Checklist 1 1/2-5. For 18 months,…

  12. Training and quality assurance with the Structured Clinical Interview for DSM-IV (SCID-I/P).

    PubMed

    Ventura, J; Liberman, R P; Green, M F; Shaner, A; Mintz, J

    1998-06-15

    Accuracy in psychiatric diagnosis is critical for evaluating the suitability of the subjects for entry into research protocols and for establishing comparability of findings across study sites. However, training programs in the use of diagnostic instruments for research projects are not well systematized. Furthermore, little information has been published on the maintenance of interrater reliability of diagnostic assessments. At the UCLA Research Center for Major Mental Illnesses, a Training and Quality Assurance Program for SCID interviewers was used to evaluate interrater reliability and diagnostic accuracy. Although clinically experienced interviewers achieved better interrater reliability and overall diagnostic accuracy than neophyte interviewers, both groups were able to achieve and maintain high levels of interrater reliability, diagnostic accuracy, and interviewer skill. At the first quality assurance check after training, there were no significant differences between experienced and neophyte interviewers in interrater reliability or diagnostic accuracy. Standardization of training and quality assurance procedures within and across research projects may make research findings from study sites more comparable.

  13. The Diagnostic Validity and Reliability of an Internet-Based Clinical Assessment Program for Mental Disorders

    PubMed Central

    Klein, Britt; Meyer, Denny; Austin, David William; Abbott, Jo-Anne M

    2015-01-01

    Background Internet-based assessment has the potential to assist with the diagnosis of mental health disorders and overcome the barriers associated with traditional services (eg, cost, stigma, distance). Further to existing online screening programs available, there is an opportunity to deliver more comprehensive and accurate diagnostic tools to supplement the assessment and treatment of mental health disorders. Objective The aim was to evaluate the diagnostic criterion validity and test-retest reliability of the electronic Psychological Assessment System (e-PASS), an online, self-report, multidisorder, clinical assessment and referral system. Methods Participants were 616 adults residing in Australia, recruited online, and representing prospective e-PASS users. Following e-PASS completion, 158 participants underwent a telephone-administered structured clinical interview and 39 participants repeated the e-PASS within 25 days of initial completion. Results With structured clinical interview results serving as the gold standard, diagnostic agreement with the e-PASS varied considerably from fair (eg, generalized anxiety disorder: κ=.37) to strong (eg, panic disorder: κ=.62). Although the e-PASS’ sensitivity also varied (0.43-0.86) the specificity was generally high (0.68-1.00). The e-PASS sensitivity generally improved when reducing the e-PASS threshold to a subclinical result. Test-retest reliability ranged from moderate (eg, specific phobia: κ=.54) to substantial (eg, bulimia nervosa: κ=.87). Conclusions The e-PASS produces reliable diagnostic results and performs generally well in excluding mental disorders, although at the expense of sensitivity. For screening purposes, the e-PASS subclinical result generally appears better than a clinical result as a diagnostic indicator. Further development and evaluation is needed to support the use of online diagnostic assessment programs for mental disorders. Trial Registration Australian and New Zealand Clinical Trials Registry ACTRN121611000704998; http://www.anzctr.org.au/trial_view.aspx?ID=336143 (Archived by WebCite at http://www.webcitation.org/618r3wvOG). PMID:26392066

  14. COMFORT scale: a reliable and valid method to measure the amount of stress of ventilated preterm infants.

    PubMed

    Wielenga, J M; De Vos, R; de Leeuw, R; De Haan, R J

    2004-01-01

    Assessment of clinimetric properties and diagnostic quality of a stress measurement scale (COMFORT scale). Sample of an open population. Neonatology department (Neonatal Intensive Care Unit), Academic Medical Centre/Emma Children's Hospital, Amsterdam, The Netherlands. One clinical expert and 9 observers observed ventilated premature born babies simultaneously. Criterion validity was assessed by correlating the COMFORT scale with the clinical judgment regarding the amount of stress. Interobserver reliability was assessed on the clinical judgment as well as on the COMFORT scale. Diagnostic qualities were evaluated with a ROC curve. On 19 ventilated prematurely born babies (mean gestational age 30 weeks, mean birth weight 1385 gm), one clinical expert and 9 observers made 30 paired observations. The criterion validity of the COMFORT scale was good (Pearson's r of 0.84). The interobserver reliability of the clinical judgment was very good (weighted Kappa 0.84). The interobserver reliability of each item varied from good to almost perfect (weighted Kappa of 0.64 for muscle tone to 1.00 on heart rate). The reliability of the total COMFORT scale score was satisfying (intra-class correlation coefficient of 0.94). The diagnostic quality of the COMFORT scale was excellent, at a cut-off point of 20 the sensitivity was 100 percent, the specificity was 77 percent, and the area under the curve (AUC) of 0.95. In this first evaluation, the COMFORT scale appears to be a valid and reliable measurement tool to assess the stress of ventilated prematurely born babies.

  15. Reliability assessment of fiber optic communication lines depending on external factors and diagnostic errors

    NASA Astrophysics Data System (ADS)

    Bogachkov, I. V.; Lutchenko, S. S.

    2018-05-01

    The article deals with the method for the assessment of the fiber optic communication lines (FOCL) reliability taking into account the effect of the optical fiber tension, the temperature influence and the built-in diagnostic equipment errors of the first kind. The reliability is assessed in terms of the availability factor using the theory of Markov chains and probabilistic mathematical modeling. To obtain a mathematical model, the following steps are performed: the FOCL state is defined and validated; the state graph and system transitions are described; the system transition of states that occur at a certain point is specified; the real and the observed time of system presence in the considered states are identified. According to the permissible value of the availability factor, it is possible to determine the limiting frequency of FOCL maintenance.

  16. Critically re-evaluating a common technique

    PubMed Central

    Geisbush, Thomas; Jones, Lyell; Weiss, Michael; Mozaffar, Tahseen; Gronseth, Gary; Rutkove, Seward B.

    2016-01-01

    Objectives: (1) To assess the diagnostic accuracy of EMG in radiculopathy. (2) To evaluate the intrarater reliability and interrater reliability of EMG in radiculopathy. (3) To assess the presence of confirmation bias in EMG. Methods: Three experienced academic electromyographers interpreted 3 compact discs with 20 EMG videos (10 normal, 10 radiculopathy) in a blinded, standardized fashion without information regarding the nature of the study. The EMGs were interpreted 3 times (discs A, B, C) 1 month apart. Clinical information was provided only with disc C. Intrarater reliability was calculated by comparing interpretations in discs A and B, interrater reliability by comparing interpretation between reviewers. Confirmation bias was estimated by the difference in correct interpretations when clinical information was provided. Results: Sensitivity was similar to previous reports (77%, confidence interval [CI] 63%–90%); specificity was 71%, CI 56%–85%. Intrarater reliability was good (κ 0.61, 95% CI 0.41–0.81); interrater reliability was lower (κ 0.53, CI 0.35–0.71). There was no substantial confirmation bias when clinical information was provided (absolute difference in correct responses 2.2%, CI −13.3% to 17.7%); the study lacked precision to exclude moderate confirmation bias. Conclusions: This study supports that (1) serial EMG studies should be performed by the same electromyographer since intrarater reliability is better than interrater reliability; (2) knowledge of clinical information does not bias EMG interpretation substantially; (3) EMG has moderate diagnostic accuracy for radiculopathy with modest specificity and electromyographers should exercise caution interpreting mild abnormalities. Classification of evidence: This study provides Class III evidence that EMG has moderate diagnostic accuracy and specificity for radiculopathy. PMID:26701380

  17. Reliability of semiquantitative assessment of osteophytes and subchondral cysts on tomosynthesis images by radiologists with different levels of expertise

    PubMed Central

    Hayashi, Daichi; Xu, Li; Gusenburg, Jeffrey; Roemer, Frank W.; Hunter, David J.; Li, Ling; Guermazi, Ali

    2014-01-01

    PURPOSE We aimed to assess reliability of the evaluation of osteophytes and subchondral cysts on tomosynthesis images when read by radiologists with different levels of expertise. MATERIALS AND METHODS Forty subjects aged >40 years had both knees evaluated using tomosynthesis. Images were read by an “experienced” reader (musculoskeletal radiologist with prior experience) and an “inexperienced” reader (radiology resident with no prior experience). Readers graded osteophytes from 0 to 3 and noted the presence/absence of subchondral cysts in four locations of the tibiofemoral joint. Twenty knees were randomly selected and re-read. Inter- and intrareader reliabilities were calculated using overall exact percent agreement and weighted κ statistics. Diagnostic performance of the two readers was compared against magnetic resonance imaging readings by an expert reader (professor of musculoskeletal radiology). RESULTS The experienced reader showed substantial intrareader reliability for graded reading of osteophytes (90%, κ=0.93), osteophyte detection (95%, κ=0.86) and cyst detection (95%, κ=0.83). The inexperienced reader showed perfect intrareader reliability for cyst detection (100%, κ=1.00) but intrareader reliability for graded reading (75%, κ=0.79) and detection (80%, κ=0.61) of osteophytes was lower than the experienced reader. Inter-reader reliability was 61% (κ=0.72) for graded osteophyte reading, 91% (κ=0.82) for osteophyte detection, and 88% (κ=0.66) for cyst detection. Diagnostic performance of the experienced reader was higher than the inexperienced reader regarding osteophyte detection (sensitivity range 0.74–0.95 vs. 0.54–0.75 for all locations) but diagnostic performance was similar for subchondral cysts. CONCLUSION Tomosynthesis offers excellent intrareader reliability regardless of the reader experience, but experience is important for detection of osteophytes. PMID:24834489

  18. FDG-PET improves accuracy in distinguishing frontotemporal dementia and Alzheimer's disease.

    PubMed

    Foster, Norman L; Heidebrink, Judith L; Clark, Christopher M; Jagust, William J; Arnold, Steven E; Barbas, Nancy R; DeCarli, Charles S; Turner, R Scott; Koeppe, Robert A; Higdon, Roger; Minoshima, Satoshi

    2007-10-01

    Distinguishing Alzheimer's disease (AD) and frontotemporal dementia (FTD) currently relies on a clinical history and examination, but positron emission tomography with [(18)F] fluorodeoxyglucose (FDG-PET) shows different patterns of hypometabolism in these disorders that might aid differential diagnosis. Six dementia experts with variable FDG-PET experience made independent, forced choice, diagnostic decisions in 45 patients with pathologically confirmed AD (n = 31) or FTD (n = 14) using five separate methods: (1) review of clinical summaries, (2) a diagnostic checklist alone, (3) summary and checklist, (4) transaxial FDG-PET scans and (5) FDG-PET stereotactic surface projection (SSP) metabolic and statistical maps. In addition, we evaluated the effect of the sequential review of a clinical summary followed by SSP. Visual interpretation of SSP images was superior to clinical assessment and had the best inter-rater reliability (mean kappa = 0.78) and diagnostic accuracy (89.6%). It also had the highest specificity (97.6%) and sensitivity (86%), and positive likelihood ratio for FTD (36.5). The addition of FDG-PET to clinical summaries increased diagnostic accuracy and confidence for both AD and FTD. It was particularly helpful when raters were uncertain in their clinical diagnosis. Visual interpretation of FDG-PET after brief training is more reliable and accurate in distinguishing FTD from AD than clinical methods alone. FDG-PET adds important information that appropriately increases diagnostic confidence, even among experienced dementia specialists.

  19. Assessment of Semi-Structured Clinical Interview for Mobile Phone Addiction Disorder.

    PubMed

    Alavi, Seyyed Salman; Mohammadi, Mohammad Reza; Jannatifard, Fereshteh; Mohammadi Kalhori, Soroush; Sepahbodi, Ghazal; BabaReisi, Mohammad; Sajedi, Sahar; Farshchi, Mojtaba; KhodaKarami, Rasul; Hatami Kasvaee, Vahid

    2016-04-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) classified mobile phone addiction disorder under "impulse control disorder not elsewhere classified". This study surveyed the diagnostic criteria of DSM-IV-TR for the diagnosis of mobile phone addiction in correspondence with Iranian society and culture. Two hundred fifty students of Tehran universities were entered into this descriptive-analytical and cross-sectional study. Quota sampling method was used. At first, semi- structured clinical interview (based on DSM-IV-TR) was performed for all the cases, and another specialist reevaluated the interviews. Data were analyzed using content validity, inter-scorer reliability (Kappa coefficient) and test-retest via SPSS18 software. The content validity of the semi- structured clinical interview matched the DSM-IV-TR criteria for behavioral addiction. Moreover, their content was appropriate, and two items, including "SMS pathological use" and "High monthly cost of using the mobile phone" were added to promote its validity. Internal reliability (Kappa) and test-retest reliability were 0.55 and r = 0.4 (p<0. 01) respectively. The results of this study revealed that semi- structured diagnostic criteria of DSM-IV-TR are valid and reliable for diagnosing mobile phone addiction, and this instrument is an effective tool to diagnose this disorder.

  20. Narrative Review: Should Teaching of the Respiratory Physical Examination Be Restricted Only to Signs with Proven Reliability and Validity?

    PubMed Central

    Baumal, Reuben

    2010-01-01

    OBJECTIVE To review the reported reliability (reproducibility, inter-examiner agreement) and validity (sensitivity, specificity and likelihood ratios) of respiratory physical examination (PE) signs, and suggest an approach to teaching these signs to medical students. METHODS Review of the literature. We searched Paper Chase between 1966 and June 2009 to identify and evaluate published studies on the diagnostic accuracy of respiratory PE signs. RESULTS Most studies have reported low to fair reliability and sensitivity values. However, some studies have found high specificites for selected PE signs. None of the studies that we reviewed adhered to all of the STARD criteria for reporting diagnostic accuracy. CONCLUSIONS Possible flaws in study designs may have led to underestimates of the observed diagnostic accuracy of respiratory PE signs. The reported poor reliabilities may have been due to differences in the PE skills of the participating examiners, while the sensitivities may have been confounded by variations in the severity of the diseases of the participating patients. IMPLICATION FOR PRACTICE AND MEDICAL EDUCATION Pending the results of properly controlled studies, the reported poor reliability and sensitivity of most respiratory PE signs do not necessarily detract from their clinical utility. Therefore, we believe that a meticulously performed respiratory PE, which aims to explore a diagnostic hypothesis, as opposed to a PE that aims to detect a disease in an asymptomatic person, remains a cornerstone of clinical practice. We propose teaching the respiratory PE signs according to their importance, beginning with signs of life-threatening conditions and those that have been reported to have a high specificity, and ending with signs that are "nice to know," but are no longer employed because of the availability of more easily performed tests. PMID:20349154

  1. Technological advances in bovine mastitis diagnosis: an overview.

    PubMed

    Duarte, Carla M; Freitas, Paulo P; Bexiga, Ricardo

    2015-11-01

    Bovine mastitis is an economic burden for dairy farmers and preventive control measures are crucial for the sustainability of any dairy business. The identification of etiological agents is necessary in controlling the disease, reducing risk of chronic infections and targeting antimicrobial therapy. The suitability of a detection method for routine diagnosis depends on several factors, including specificity, sensitivity, cost, time in producing results, and suitability for large-scale sampling of milk. This article focuses on current methodologies for identification of mastitis pathogens and for detection of inflammation, as well as the advantages and disadvantages of different methods. Emerging technologies, such as transcriptome and proteome analyses and nano- and microfabrication of portable devices, offer promising, sensitive methods for advanced detection of mastitis pathogens and biomarkers of inflammation. The demand for alternative, fast, and reliable diagnostic procedures is rising as farms become bigger. Several examples of technological and scientific advances are summarized which have given rise to more sensitive, reliable and faster diagnostic results. © 2015 The Author(s).

  2. Comparison of three methods for the detection of Trichinella spiralis infections in pigs by five European laboratories*

    PubMed Central

    Kohler, G.; Ruitenberg, E. J.

    1974-01-01

    Three methods employed in the diagnosis of trichinosis (trichinoscopy, digestion method, and immunofluorescence technique) were compared by laboratories in 5 countries of the European economic community. For this purpose, material from 32 pigs infected with 50, 150, 500, and 1 500 T. spiralis larvae was examined. With none of the three methods was it possible to detect with sufficient reliability a T. spiralis infection in pigs infected with 50 larvae. The digestion method and the immunofluorescence technique yielded more reliable results when the infection dose was 150 larvae or more. With trichinoscopy, reliable results were obtained in pigs infected with 500 and 1 500 larvae. With the digestion method and trichinoscopy, the onset of infections was detectable from 3 weeks post infection, the digestion method being more reliable; the immunofluorescence technique yielded positive results from approximately 4-6 weeks post infection. The immunofluorescence technique is applicable for epidemiological surveys. As a routine diagnostic procedure in the slaughterhouse, trichinoscopy and the digestion method are possible alternatives, the latter being more sensitive. PMID:4616776

  3. A study on the value of computer-assisted assessment for SPECT/CT-scans in sentinel lymph node diagnostics of penile cancer as well as clinical reliability and morbidity of this procedure.

    PubMed

    Lützen, Ulf; Naumann, Carsten Maik; Marx, Marlies; Zhao, Yi; Jüptner, Michael; Baumann, René; Papp, László; Zsótér, Norbert; Aksenov, Alexey; Jünemann, Klaus-Peter; Zuhayra, Maaz

    2016-09-07

    Because of the increasing importance of computer-assisted post processing of image data in modern medical diagnostic we studied the value of an algorithm for assessment of single photon emission computed tomography/computed tomography (SPECT/CT)-data, which has been used for the first time for lymph node staging in penile cancer with non-palpable inguinal lymph nodes. In the guidelines of the relevant international expert societies, sentinel lymph node-biopsy (SLNB) is recommended as a diagnostic method of choice. The aim of this study is to evaluate the value of the afore-mentioned algorithm and in the clinical context the reliability and the associated morbidity of this procedure. Between 2008 and 2015, 25 patients with invasive penile cancer and inconspicuous inguinal lymph node status underwent SLNB after application of the radiotracer Tc-99m labelled nanocolloid. We recorded in a prospective approach the reliability and the complication rate of the procedure. In addition, we evaluated the results of an algorithm for SPECT/CT-data assessment of these patients. SLNB was carried out in 44 groins of 25 patients. In three patients, inguinal lymph node metastases were detected via SLNB. In one patient, bilateral lymph node recurrence of the groins occurred after negative SLNB. There was a false-negative rate of 4 % in relation to the number of patients (1/25), resp. 4.5 % in relation to the number of groins (2/44). Morbidity was 4 % in relation to the number of patients (1/25), resp. 2.3 % in relation to the number of groins (1/44). The results of computer-assisted assessment of SPECT/CT data for sentinel lymph node (SLN)-diagnostics demonstrated high sensitivity of 88.8 % and specificity of 86.7 %. SLNB is a very reliable method, associated with low morbidity. Computer-assisted assessment of SPECT/CT data of the SLN-diagnostics shows high sensitivity and specificity. While it cannot replace the assessment by medical experts, it can still provide substantial supplement and assistance.

  4. Diagnostic emulation: Implementation and user's guide

    NASA Technical Reports Server (NTRS)

    Becher, Bernice

    1987-01-01

    The Diagnostic Emulation Technique was developed within the System Validation Methods Branch as a part of the development of methods for the analysis of the reliability of highly reliable, fault tolerant digital avionics systems. This is a general technique which allows for the emulation of a digital hardware system. The technique is general in the sense that it is completely independent of the particular target hardware which is being emulated. Parts of the system are described and emulated at the logic or gate level, while other parts of the system are described and emulated at the functional level. This algorithm allows for the insertion of faults into the system, and for the observation of the response of the system to these faults. This allows for controlled and accelerated testing of system reaction to hardware failures in the target machine. This document describes in detail how the algorithm was implemented at NASA Langley Research Center and gives instructions for using the system.

  5. Microfluidic paper-based analytical devices for potential use in quantitative and direct detection of disease biomarkers in clinical analysis.

    PubMed

    Lim, Wei Yin; Goh, Boon Tong; Khor, Sook Mei

    2017-08-15

    Clinicians, working in the health-care diagnostic systems of developing countries, currently face the challenges of rising costs, increased number of patient visits, and limited resources. A significant trend is using low-cost substrates to develop microfluidic devices for diagnostic purposes. Various fabrication techniques, materials, and detection methods have been explored to develop these devices. Microfluidic paper-based analytical devices (μPADs) have gained attention for sensing multiplex analytes, confirming diagnostic test results, rapid sample analysis, and reducing the volume of samples and analytical reagents. μPADs, which can provide accurate and reliable direct measurement without sample pretreatment, can reduce patient medical burden and yield rapid test results, aiding physicians in choosing appropriate treatment. The objectives of this review are to provide an overview of the strategies used for developing paper-based sensors with enhanced analytical performances and to discuss the current challenges, limitations, advantages, disadvantages, and future prospects of paper-based microfluidic platforms in clinical diagnostics. μPADs, with validated and justified analytical performances, can potentially improve the quality of life by providing inexpensive, rapid, portable, biodegradable, and reliable diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Squash preparation: A reliable diagnostic tool in the intraoperative diagnosis of central nervous system tumors

    PubMed Central

    Mitra, Sumit; Kumar, Mohan; Sharma, Vivek; Mukhopadhyay, Debasis

    2010-01-01

    Background: Intraoperative cytology is an important diagnostic modality improving on the accuracy of the frozen sections. It has shown to play an important role especially in the intraoperative diagnosis of central nervous system tumors. Aim: To study the diagnostic accuracy of squash preparation and frozen section (FS) in the intraoperative diagnosis of central nervous system (CNS) tumors. Materials and Methods: This prospective study of 114 patients with CNS tumors was conducted over a period of 18 months (September 2004 to February 2006). The cytological preparations were stained by the quick Papanicolaou method. The squash interpretation and FS diagnosis were later compared with the paraffin section diagnosis. Results: Of the 114 patients, cytological diagnosis was offered in 96 cases. Eighteen nonneoplastic or noncontributory cases were excluded. Using hematoxylin and eosin-stained histopathology sections as the gold standard, the diagnostic accuracy of cytology was 88.5% (85/96) and the accuracy on FS diagnosis was 90.6% (87/96). Among these cases, gliomas formed the largest category of tumors (55.2%). The cytological accuracy in this group was 84.9% (45/53) and the comparative FS figure was 86.8% (46/53). In cases where the smear and the FS diagnosis did not match, the latter opinion was offered. Conclusions: Squash preparation is a reliable, rapid and easy method and can be used as a complement to FS in the intraoperative diagnosis of CNS tumors. PMID:21187881

  7. Indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain: protocol of an inter-examiner reliability study among manual therapists

    PubMed Central

    2014-01-01

    Background Manual spinal joint mobilisations and manipulations are widely used treatments in patients with neck and low-back pain. Inter-examiner reliability of passive intervertebral motion assessment of the cervical and lumbar spine, perceived as important for indicating these interventions, is poor within a univariable approach. The diagnostic process as a whole in daily practice in manual therapy has a multivariable character, however, in which the use and interpretation of passive intervertebral motion assessment depend on earlier results from the diagnostic process. To date, the inter-examiner reliability among manual therapists of a multivariable diagnostic decision-making process in patients with neck or low-back pain is unknown. Methods This study will be conducted as a repeated-measures design in which 14 pairs of manual therapists independently examine a consecutive series of a planned total of 165 patients with neck or low-back pain presenting in primary care physiotherapy. Primary outcome measure is therapists’ decision about whether or not manual spinal joint mobilisations or manipulations, or both, are indicated in each patient, alone or as part of a multimodal treatment. Therapists will largely be free to conduct the full diagnostic process based on their formulated examination objectives. For each pair of therapists, 2×2 tables will be constructed and reliability for the dichotomous decision will be expressed using Cohen’s kappa. In addition, observed agreement, prevalence of positive decisions, prevalence index, bias index, and specific agreement in positive and negative decisions will be calculated. Univariable logistic regression analysis of concordant decisions will be performed to explore which demographic, professional, or clinical factors contributed to reliability. Discussion This study will provide an estimate of the inter-examiner reliability among manual therapists of indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain based on a multivariable diagnostic reasoning and decision-making process, as opposed to reliability of individual tests. As such, it is proposed as an initial step toward the development of an alternative approach to current classification systems and prediction rules for identifying those patients with spinal disorders that may show a better response to manual therapy which can be incorporated in randomised clinical trials. Potential methodological limitations of this study are discussed. PMID:24982754

  8. A Diagnostic Marker to Discriminate Childhood Apraxia of Speech from Speech Delay: III. Theoretical Coherence of the Pause Marker with Speech Processing Deficits in Childhood Apraxia of Speech

    ERIC Educational Resources Information Center

    Shriberg, Lawrence D.; Strand, Edythe A.; Fourakis, Marios; Jakielski, Kathy J.; Hall, Sheryl D.; Karlsson, Heather B.; Mabie, Heather L.; McSweeny, Jane L.; Tilkens, Christie M.; Wilson, David L.

    2017-01-01

    Purpose: Previous articles in this supplement described rationale for and development of the pause marker (PM), a diagnostic marker of childhood apraxia of speech (CAS), and studies supporting its validity and reliability. The present article assesses the theoretical coherence of the PM with speech processing deficits in CAS. Method: PM and other…

  9. Diagnostic reliability of the cervical vertebral maturation method and standing height in the identification of the mandibular growth spurt.

    PubMed

    Perinetti, Giuseppe; Contardo, Luca; Castaldo, Attilio; McNamara, James A; Franchi, Lorenzo

    2016-07-01

    To evaluate the capability of both cervical vertebral maturation (CVM) stages 3 and 4 (CS3-4 interval) and the peak in standing height to identify the mandibular growth spurt throughout diagnostic reliability analysis. A previous longitudinal data set derived from 24 untreated growing subjects (15 females and nine males,) detailed elsewhere were reanalyzed. Mandibular growth was defined as annual increments in Condylion (Co)-Gnathion (Gn) (total mandibular length) and Co-Gonion Intersection (Goi) (ramus height) and their arithmetic mean (mean mandibular growth [mMG]). Subsequently, individual annual increments in standing height, Co-Gn, Co-Goi, and mMG were arranged according to annual age intervals, with the first and last intervals defined as 7-8 years and 15-16 years, respectively. An analysis was performed to establish the diagnostic reliability of the CS3-4 interval or the peak in standing height in the identification of the maximum individual increments of each Co-Gn, Co-Goi, and mMG measurement at each annual age interval. CS3-4 and standing height peak show similar but variable accuracy across annual age intervals, registering values between 0.61 (standing height peak, Co-Gn) and 0.95 (standing height peak and CS3-4, mMG). Generally, satisfactory diagnostic reliability was seen when the mandibular growth spurt was identified on the basis of the Co-Goi and mMG increments. Both CVM interval CS3-4 and peak in standing height may be used in routine clinical practice to enhance efficiency of treatments requiring identification of the mandibular growth spurt.

  10. Physical examination tests for screening and diagnosis of cervicogenic headache: A systematic review.

    PubMed

    Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E

    2016-02-01

    It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. FNAC: its role, limitations and perspective in the preoperative diagnosis of breast cancer.

    PubMed

    Zagorianakou, P; Fiaccavento, S; Zagorianakou, N; Makrydimas, G; Stefanou, D; Agnantis, N J

    2005-01-01

    Fine-needle aspiration cytology (FNAC) was first described and performed in 1930. Thirty years later, it gained acceptance first in Europe and about a decade later in North America. The method is generally considered as a rapid, reliable, safe diagnostic tool to distinguish non-neoplastic from neoplastic breast lesions. In developed countries, in the last 20 years, mammographic screening programmes, which have been used extensively, are designed to detect the earliest possible breast cancer. The FNAC report is extremely important because it gives the necessary information for the management of patients, in order to proceed with more invasive diagnostic methods or surgical treatment, and to decide what kind of operation to perform. In the preoperative phase, FNAC has taken a fundamental role of both palpable and nonpalpable lesions, using ultrasound or stereotactic guidance. New developed techniques, breast biopsy instrumentation (ABBI) and mammotome have the advantage of complete removal of breast lesions, but this is not possible in all the examined cases. In developing countries, economical restrictions, low budget for health care and screening programmes put the patients at a disadvantage because of the high cost of sophisticated diagnostic methods, thus we recommend that FNAC be used as a routine diagnostic method because of its low cost compared with the others and this policy maximizes the availability of health care to women with breast cancer. We conclude that FNAC plays an important and essential role in the management of patients with breast lesions and also offers a great potential for prediction of patient outcome, disease response to therapy and assessment of risk of developing breast cancer. The reliability and efficiency of the method depends on the quality of the samples and the experience of the medical staff that performs the aspiration.

  12. The reliability of psychiatric diagnosis in the emergency room.

    PubMed

    Lieberman, P B; Baker, F M

    1985-03-01

    The authors compared the diagnoses made for 50 patients in an emergency room with those made during a subsequent inpatient hospitalization. They found an acceptable level of reliability for broad diagnostic categories, such as psychosis, depression, and alcoholism. The authors believe such diagnostic reliability is sufficient for emergency assessment and triage. However, the diagnosis of more specific subtypes of mental illness, such as schizophrenia and bipolar disorder, were not made reliably in the emergency room. The authors point out the risk of diagnostic labeling, and suggest that the tendency to overlook nonalcoholic substance abuse deserves special attention.

  13. Can we improve the clinical utility of respiratory rate as a monitored vital sign?

    PubMed

    Chen, Liangyou; Reisner, Andrew T; Gribok, Andrei; McKenna, Thomas M; Reifman, Jaques

    2009-06-01

    Respiratory rate (RR) is a basic vital sign, measured and monitored throughout a wide spectrum of health care settings, although RR is historically difficult to measure in a reliable fashion. We explore an automated method that computes RR only during intervals of clean, regular, and consistent respiration and investigate its diagnostic use in a retrospective analysis of prehospital trauma casualties. At least 5 s of basic vital signs, including heart rate, RR, and systolic, diastolic, and mean arterial blood pressures, were continuously collected from 326 spontaneously breathing trauma casualties during helicopter transport to a level I trauma center. "Reliable" RR data were identified retrospectively using automated algorithms. The diagnostic performances of reliable versus standard RR were evaluated by calculation of the receiver operating characteristic curves using the maximum-likelihood method and comparison of the summary areas under the receiver operating characteristic curves (AUCs). Respiratory rate shows significant data-reliability differences. For identifying prehospital casualties who subsequently receive a respiratory intervention (hospital intubation or tube thoracotomy), standard RR yields an AUC of 0.59 (95% confidence interval, 0.48-0.69), whereas reliable RR yields an AUC of 0.67 (0.57-0.77), P < 0.05. For identifying casualties subsequently diagnosed with a major hemorrhagic injury and requiring blood transfusion, standard RR yields an AUC of 0.60 (0.49-0.70), whereas reliable RR yields 0.77 (0.67-0.85), P < 0.001. Reliable RR, as determined by an automated algorithm, is a useful parameter for the diagnosis of respiratory pathology and major hemorrhage in a trauma population. It may be a useful input to a wide variety of clinical scores and automated decision-support algorithms.

  14. Validation and Test-Retest Reliability of New Thermographic Technique Called Thermovision Technique of Dry Needling for Gluteus Minimus Trigger Points in Sciatica Subjects and TrPs-Negative Healthy Volunteers

    PubMed Central

    Rychlik, Michał; Samborski, Włodzimierz

    2015-01-01

    The aim of this study was to assess the validity and test-retest reliability of Thermovision Technique of Dry Needling (TTDN) for the gluteus minimus muscle. TTDN is a new thermography approach used to support trigger points (TrPs) diagnostic criteria by presence of short-term vasomotor reactions occurring in the area where TrPs refer pain. Method. Thirty chronic sciatica patients (n=15 TrP-positive and n=15 TrPs-negative) and 15 healthy volunteers were evaluated by TTDN three times during two consecutive days based on TrPs of the gluteus minimus muscle confirmed additionally by referred pain presence. TTDN employs average temperature (T avr), maximum temperature (T max), low/high isothermal-area, and autonomic referred pain phenomenon (AURP) that reflects vasodilatation/vasoconstriction. Validity and test-retest reliability were assessed concurrently. Results. Two components of TTDN validity and reliability, T avr and AURP, had almost perfect agreement according to κ (e.g., thigh: 0.880 and 0.938; calf: 0.902 and 0.956, resp.). The sensitivity for T avr, T max, AURP, and high isothermal-area was 100% for everyone, but specificity of 100% was for T avr and AURP only. Conclusion. TTDN is a valid and reliable method for T avr and AURP measurement to support TrPs diagnostic criteria for the gluteus minimus muscle when digitally evoked referred pain pattern is present. PMID:26137486

  15. [Evaluation (assessment) of three tests for diagnosis of geohelmints in Colombia].

    PubMed

    López, Myriam Consuelo; Moncada, Ligia Inés; Ariza-Araújo, Yoseth; Fernández-Niño, Julián Alfredo; Reyes, Patricia; Nicholls, Rubén Santiago

    2013-01-01

    Soil-transmitted helminth infections are considered a public health problem in developing countries. The diagnostic tests, both for individual parient diagnosis as for population studies should be evaluated in terms of validity and reliability. To compare the direct examination, the modified Ritchie-Frick method, a Kato-Katz designed by a Brazilian group and one designed by the WHO, for the diagnosis of soil-transmitted helminthes. A diagnostic test reliability study was performed. The same stool sample was analyzed by the same observer using four diagnostic tests. 204 samples were obtained, 194 of those fulfilled the inclusion criteria and were analyzed. The observers did not know the participants' identity neither the other tests results. For the analysis the Kato-Katz (WHO) was considered as the gold standard. For the reliability assessment percent agreement, positive percent agreement, Kappa statistic, and intraclass correlation were performed. The Brazilian Kato-Katz showed a good performance with high sensitivity and specificity for T. trichiura and Hookworm with values of 0.97 and 0.96 respectively, and a high specificity with mild sensitivity for A. lumbricoides (0.95 and 0.79) meanwhile the direct examination and the Ritche-Frick method showed a performance between mild and poor. The differences were higher for hookworm and Trichiuris trichiura than for Ascaris lumbricoides. The Brazilian Kato Katz test could be implemented, but further studies are needed to correlate its operative capacity with its feasibility, availability and cost.

  16. Development and content validity testing of a comprehensive classification of diagnoses for pediatric nurse practitioners.

    PubMed

    Burns, C

    1991-01-01

    Pediatric nurse practitioners (PNPs) need an integrated, comprehensive classification that includes nursing, disease, and developmental diagnoses to effectively describe their practice. No such classification exists. Further, methodologic studies to help evaluate the content validity of any nursing taxonomy are unavailable. A conceptual framework was derived. Then 178 diagnoses from the North American Nursing Diagnosis Association (NANDA) 1986 list, selected diagnoses from the International Classification of Diseases, the Diagnostic and Statistical Manual, Third Revision, and others were selected. This framework identified and listed, with definitions, three domains of diagnoses: Developmental Problems, Diseases, and Daily Living Problems. The diagnoses were ranked using a 4-point scale (4 = highly related to 1 = not related) and were placed into the three domains. The rating scale was assigned by a panel of eight expert pediatric nurses. Diagnoses that were assigned to the Daily Living Problems domain were then sorted into the 11 Functional Health patterns described by Gordon (1987). Reliability was measured using proportions of agreement and Kappas. Content validity of the groups created was measured using indices of content validity and average congruency percentages. The experts used a new method to sort the diagnoses in a new way that decreased overlaps among the domains. The Developmental and Disease domains were judged reliable and valid. The Daily Living domain of nursing diagnoses showed marginally acceptable validity with acceptable reliability. Six Functional Health Patterns were judged reliable and valid, mixed results were determined for four categories, and the Coping/Stress Tolerance category was judged reliable but not valid using either test. There were considerable differences between the panel's, Gordon's (1987), and NANDA's clustering of NANDA diagnoses. This study defines the diagnostic practice of nurses from a holistic, patient-centered perspective. It is the first study to use quantitative methods to test a diagnostic classification system for nursing. The classification model could also be adapted for other nurse specialties.

  17. Validity and reliability of Internet-based physiotherapy assessment for musculoskeletal disorders: a systematic review.

    PubMed

    Mani, Suresh; Sharma, Shobha; Omar, Baharudin; Paungmali, Aatit; Joseph, Leonard

    2017-04-01

    Purpose The purpose of this review is to systematically explore and summarise the validity and reliability of telerehabilitation (TR)-based physiotherapy assessment for musculoskeletal disorders. Method A comprehensive systematic literature review was conducted using a number of electronic databases: PubMed, EMBASE, PsycINFO, Cochrane Library and CINAHL, published between January 2000 and May 2015. The studies examined the validity, inter- and intra-rater reliabilities of TR-based physiotherapy assessment for musculoskeletal conditions were included. Two independent reviewers used the Quality Appraisal Tool for studies of diagnostic Reliability (QAREL) and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool to assess the methodological quality of reliability and validity studies respectively. Results A total of 898 hits were achieved, of which 11 articles based on inclusion criteria were reviewed. Nine studies explored the concurrent validity, inter- and intra-rater reliabilities, while two studies examined only the concurrent validity. Reviewed studies were moderate to good in methodological quality. The physiotherapy assessments such as pain, swelling, range of motion, muscle strength, balance, gait and functional assessment demonstrated good concurrent validity. However, the reported concurrent validity of lumbar spine posture, special orthopaedic tests, neurodynamic tests and scar assessments ranged from low to moderate. Conclusion TR-based physiotherapy assessment was technically feasible with overall good concurrent validity and excellent reliability, except for lumbar spine posture, orthopaedic special tests, neurodynamic testa and scar assessment.

  18. Reliability and validity of urinary nerve growth factor measurement in women with lower urinary tract symptoms.

    PubMed

    Vijaya, Gopalan; Cartwright, Rufus; Bhide, Alka; Derpapas, Alexandros; Fernando, Ruwan; Khullar, Vik

    2016-11-01

    The validity and reliability of measurement of urinary NGF as a diagnostic biomarker in women with lower urinary tract dysfunction (LUTD) is uncertain. We aimed to evaluate both the diagnostic and discriminant validity, and the test-retest reliability of urinary NGF measurement in women with LUTD. Urinary NGF was measured in women with LUTD (n = 205) and asymptomatic subjects (n = 31). Urinary NGF was assayed using an ELISA method and normalized against urinary creatinine. NGF/creatinine ratios were compared between symptom subgroups using Mann-Whitney U test, and between different urodynamic diagnoses using the Kruskal-Wallis test. Receiver Operator Characteristic (ROC) analysis was employed to evaluate the diagnostic performance of urinary NGF. Test-retest reliability of NGF measurement was assessed using intra-class correlation (ICC). Urinary NGF was significantly but non-specifically increased in symptomatic patients when compared to controls (13.33 vs. 2.05 ng NGF/g Cr, P < 0.001). On multivariate logistic regression NGF was a good predictor of patients having OAB or not, however, the adjusted odds ratio only 1.006. ROC analysis demonstrated poor discriminant ability between different symptomatic groups and urodynamic groups. Using a cut off of 13.0 ng NGF/g creatinine the test provides a sensitivity of 81%, but a specificity of only 39% for overactive bladder. The assays demonstrated good test-retest reliability with ICC of 0.889. Although urinary NGF can be reliably assayed, and is increased in various LUTDs, it discriminates poorly between these disorders therefore has very limited potential as a biomarker. Neurourol. Urodynam. 35:944-948, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. Reliability and Validity of Autism Diagnostic Interview-Revised, Japanese Version

    ERIC Educational Resources Information Center

    Tsuchiya, Kenji J.; Matsumoto, Kaori; Yagi, Atsuko; Inada, Naoko; Kuroda, Miho; Inokuchi, Eiko; Koyama, Tomonori; Kamio, Yoko; Tsujii, Masatsugu; Sakai, Saeko; Mohri, Ikuko; Taniike, Masako; Iwanaga, Ryoichiro; Ogasahara, Kei; Miyachi, Taishi; Nakajima, Shunji; Tani, Iori; Ohnishi, Masafumi; Inoue, Masahiko; Nomura, Kazuyo; Hagiwara, Taku; Uchiyama, Tokio; Ichikawa, Hironobu; Kobayashi, Shuji; Miyamoto, Ken; Nakamura, Kazuhiko; Suzuki, Katsuaki; Mori, Norio; Takei, Nori

    2013-01-01

    To examine the inter-rater reliability of Autism Diagnostic Interview-Revised, Japanese Version (ADI-R-JV), the authors recruited 51 individuals aged 3-19 years, interviewed by two independent raters. Subsequently, to assess the discriminant and diagnostic validity of ADI-R-JV, the authors investigated 317 individuals aged 2-19 years, who were…

  20. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    NASA Technical Reports Server (NTRS)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  1. A multivariate time series approach to modeling and forecasting demand in the emergency department.

    PubMed

    Jones, Spencer S; Evans, R Scott; Allen, Todd L; Thomas, Alun; Haug, Peter J; Welch, Shari J; Snow, Gregory L

    2009-02-01

    The goals of this investigation were to study the temporal relationships between the demands for key resources in the emergency department (ED) and the inpatient hospital, and to develop multivariate forecasting models. Hourly data were collected from three diverse hospitals for the year 2006. Descriptive analysis and model fitting were carried out using graphical and multivariate time series methods. Multivariate models were compared to a univariate benchmark model in terms of their ability to provide out-of-sample forecasts of ED census and the demands for diagnostic resources. Descriptive analyses revealed little temporal interaction between the demand for inpatient resources and the demand for ED resources at the facilities considered. Multivariate models provided more accurate forecasts of ED census and of the demands for diagnostic resources. Our results suggest that multivariate time series models can be used to reliably forecast ED patient census; however, forecasts of the demands for diagnostic resources were not sufficiently reliable to be useful in the clinical setting.

  2. Reliability and diagnostic characteristics of the JFK coma recovery scale-revised: exploring the influence of rater's level of experience.

    PubMed

    Løvstad, Marianne; Frøslie, Kathrine F; Giacino, Joseph T; Skandsen, Toril; Anke, Audny; Schanke, Anne-Kristine

    2010-01-01

    To confirm the reliability and diagnostic validity of the JFK Coma Recovery Scale-Revised (CRS-R) across raters with varying levels of experience. Thirty-one patients with disorders of consciousness were recruited from 6 Norwegian hospitals. CRS-R and the Disability Rating Scale. Reliability measures were good for the CRS-R total scores and moderate to good for its subscales. Diagnostic agreement among examiners was good. Raters' experience with the CRS-R favorably influenced reliability. Sensitivity and specificity analyses demonstrated better detection of patients in minimally conscious state on the CRS-R relative to the Disability Rating Scale. The CRS-R is a reliable tool for diagnosing vegetative state and minimally conscious state. Raters' level of experience influences the reliability of the CRS-R scores.

  3. Binge Eating Disorder: Reliability and Validity of a New Diagnostic Category.

    ERIC Educational Resources Information Center

    Brody, Michelle L.; And Others

    1994-01-01

    Examined reliability and validity of binge eating disorder (BED), proposed for inclusion in Diagnostic and Statistical Manual of Mental Disorders (DSM), fourth edition. Interrater reliability of BED diagnosis compared favorably with that of most diagnoses in DSM revised third edition. Study comparing obese individuals with and without BED and…

  4. Rapid and sensitive detection of Yersinia pestis using amplification of plague diagnostic bacteriophages monitored by real-time PCR.

    PubMed

    Sergueev, Kirill V; He, Yunxiu; Borschel, Richard H; Nikolich, Mikeljon P; Filippov, Andrey A

    2010-06-28

    Yersinia pestis, the agent of plague, has caused many millions of human deaths and still poses a serious threat to global public health. Timely and reliable detection of such a dangerous pathogen is of critical importance. Lysis by specific bacteriophages remains an essential method of Y. pestis detection and plague diagnostics. The objective of this work was to develop an alternative to conventional phage lysis tests--a rapid and highly sensitive method of indirect detection of live Y. pestis cells based on quantitative real-time PCR (qPCR) monitoring of amplification of reporter Y. pestis-specific bacteriophages. Plague diagnostic phages phiA1122 and L-413C were shown to be highly effective diagnostic tools for the detection and identification of Y. pestis by using qPCR with primers specific for phage DNA. The template DNA extraction step that usually precedes qPCR was omitted. phiA1122-specific qPCR enabled the detection of an initial bacterial concentration of 10(3) CFU/ml (equivalent to as few as one Y. pestis cell per 1-microl sample) in four hours. L-413C-mediated detection of Y. pestis was less sensitive (up to 100 bacteria per sample) but more specific, and thus we propose parallel qPCR for the two phages as a rapid and reliable method of Y. pestis identification. Importantly, phiA1122 propagated in simulated clinical blood specimens containing EDTA and its titer rise was detected by both a standard plating test and qPCR. Thus, we developed a novel assay for detection and identification of Y. pestis using amplification of specific phages monitored by qPCR. The method is simple, rapid, highly sensitive, and specific and allows the detection of only live bacteria.

  5. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    PubMed Central

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  6. Microbial Diagnostic Microarrays for the Detection and Typing of Food- and Water-Borne (Bacterial) Pathogens

    PubMed Central

    Kostić, Tanja; Sessitsch, Angela

    2011-01-01

    Reliable and sensitive pathogen detection in clinical and environmental (including food and water) samples is of greatest importance for public health. Standard microbiological methods have several limitations and improved alternatives are needed. Most important requirements for reliable analysis include: (i) specificity; (ii) sensitivity; (iii) multiplexing potential; (iv) robustness; (v) speed; (vi) automation potential; and (vii) low cost. Microarray technology can, through its very nature, fulfill many of these requirements directly and the remaining challenges have been tackled. In this review, we attempt to compare performance characteristics of the microbial diagnostic microarrays developed for the detection and typing of food and water pathogens, and discuss limitations, points still to be addressed and issues specific for the analysis of food, water and environmental samples. PMID:27605332

  7. Immunohistochemistry: forging the links between immunology and pathology.

    PubMed

    Haines, Deborah M; West, Keith H

    2005-10-18

    The technique of immunohistochemical staining allows the visualization of epitopes in situ in histological tissue sections. A series of innovations in the methods and reagents and the introduction of mechanization have enhanced the ease and technical reliability of this technique resulting in widespread application in veterinary diagnostics and research. This brief overview will highlight some of the applications for immunohistochemical staining with an emphasis on the use of the technique in diagnostic veterinary medicine, particularly for the detection of infectious disease agents.

  8. NGS of Virus-Derived Small RNAs as a Diagnostic Method Used to Determine Viromes of Hungarian Vineyards

    PubMed Central

    Czotter, Nikoletta; Molnar, Janos; Szabó, Emese; Demian, Emese; Kontra, Levente; Baksa, Ivett; Szittya, Gyorgy; Kocsis, Laszlo; Deak, Tamas; Bisztray, Gyorgy; Tusnady, Gabor E.; Burgyan, Jozsef; Varallyay, Eva

    2018-01-01

    As virus diseases cannot be controlled by traditional plant protection methods, the risk of their spread have to be minimized on vegetatively propagated plants, such as grapevine. Metagenomic approaches used for virus diagnostics offer a unique opportunity to reveal the presence of all viral pathogens in the investigated plant, which is why their application can reduce the risk of using infected material for a new plantation. Here we used a special branch, deep sequencing of virus-derived small RNAs, of this high-throughput method for virus diagnostics, and determined viromes of vineyards in Hungary. With NGS of virus-derived small RNAs we could detect not only the viruses tested routinely, but also new ones, which had never been described in Hungary before. Virus presence did not correlate with the age of the plantation, moreover phylogenetic analysis of the identified virus isolates suggests that infections are mostly caused by the use of infected propagating material. Our results, validated by other molecular methods, raised further questions to be answered before this method can be introduced as a routine, reliable test for grapevine virus diagnostics. PMID:25741336

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Veronica J.; ANU)

    An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatorymore » test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.« less

  10. Immune Response to Mycobacterial Infection: Lessons from Flow Cytometry

    PubMed Central

    Rovina, Nikoletta; Panagiotou, Marios; Koulouris, Nikolaos G.

    2013-01-01

    Detecting and treating active and latent tuberculosis are pivotal elements for effective infection control; yet, due to their significant inherent limitations, the diagnostic means for these two stages of tuberculosis (TB) to date remain suboptimal. This paper reviews the current diagnostic tools for mycobacterial infection and focuses on the application of flow cytometry as a promising method for rapid and reliable diagnosis of mycobacterial infection as well as discrimination between active and latent TB: it summarizes diagnostic biomarkers distinguishing the two states of infection and also features of the distinct immune response against Mycobacterium tuberculosis (Mtb) at certain stages of infection as revealed by flow cytometry to date. PMID:24376464

  11. Immune response to mycobacterial infection: lessons from flow cytometry.

    PubMed

    Rovina, Nikoletta; Panagiotou, Marios; Pontikis, Konstantinos; Kyriakopoulou, Magdalini; Koulouris, Nikolaos G; Koutsoukou, Antonia

    2013-01-01

    Detecting and treating active and latent tuberculosis are pivotal elements for effective infection control; yet, due to their significant inherent limitations, the diagnostic means for these two stages of tuberculosis (TB) to date remain suboptimal. This paper reviews the current diagnostic tools for mycobacterial infection and focuses on the application of flow cytometry as a promising method for rapid and reliable diagnosis of mycobacterial infection as well as discrimination between active and latent TB: it summarizes diagnostic biomarkers distinguishing the two states of infection and also features of the distinct immune response against Mycobacterium tuberculosis (Mtb) at certain stages of infection as revealed by flow cytometry to date.

  12. Custom oligonucleotide array-based CGH: a reliable diagnostic tool for detection of exonic copy-number changes in multiple targeted genes

    PubMed Central

    Vasson, Aurélie; Leroux, Céline; Orhant, Lucie; Boimard, Mathieu; Toussaint, Aurélie; Leroy, Chrystel; Commere, Virginie; Ghiotti, Tiffany; Deburgrave, Nathalie; Saillour, Yoann; Atlan, Isabelle; Fouveaut, Corinne; Beldjord, Cherif; Valleix, Sophie; Leturcq, France; Dodé, Catherine; Bienvenu, Thierry; Chelly, Jamel; Cossée, Mireille

    2013-01-01

    The frequency of disease-related large rearrangements (referred to as copy-number mutations, CNMs) varies among genes, and search for these mutations has an important place in diagnostic strategies. In recent years, CGH method using custom-designed high-density oligonucleotide-based arrays allowed the development of a powerful tool for detection of alterations at the level of exons and made it possible to provide flexibility through the possibility of modeling chips. The aim of our study was to test custom-designed oligonucleotide CGH array in a diagnostic laboratory setting that analyses several genes involved in various genetic diseases, and to compare it with conventional strategies. To this end, we designed a 12-plex CGH array (135k; 135 000 probes/subarray) (Roche Nimblegen) with exonic and intronic oligonucleotide probes covering 26 genes routinely analyzed in the laboratory. We tested control samples with known CNMs and patients for whom genetic causes underlying their disorders were unknown. The contribution of this technique is undeniable. Indeed, it appeared reproducible, reliable and sensitive enough to detect heterozygous single-exon deletions or duplications, complex rearrangements and somatic mosaicism. In addition, it improves reliability of CNM detection and allows determination of boundaries precisely enough to direct targeted sequencing of breakpoints. All of these points, associated with the possibility of a simultaneous analysis of several genes and scalability ‘homemade' make it a valuable tool as a new diagnostic approach of CNMs. PMID:23340513

  13. A Study on the Reliability of Sasang Constitutional Body Trunk Measurement

    PubMed Central

    Jang, Eunsu; Kim, Jong Yeol; Lee, Haejung; Kim, Honggie; Baek, Younghwa; Lee, Siwoo

    2012-01-01

    Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM). The Sasang constitutional body trunk measurement (SCBTM) consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs) was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM. PMID:21822442

  14. TH-F-209-01: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Behling, R.

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, themore » aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate critical situations Understand the meaning of different warranty models I am employee of Royal Philips; R. Behling, No external funding. I am employee of Royal Philips.« less

  15. TH-F-209-00: Pitfalls: Reliability and Performance of Diagnostic X-Ray Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, themore » aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. Learning Objectives: Understand the basic requirements on medical diagnostic X-ray sources per modality Learn to select the optimal equipment employing state-of-the-art metric Know causes of failures, depending on the way X-ray sources are operated Understand methods to remediate critical situations Understand the meaning of different warranty models I am employee of Royal Philips; R. Behling, No external funding. I am employee of Royal Philips.« less

  16. Future of diagnostic microbiology.

    PubMed

    Khardori, N

    2014-01-01

    Diagnostic Microbiology is the tool that makes it possible to identify the exact etiology of infectious diseases and the most optimal therapy at the level of individual patients as well as communities. Conventional methods require time to grow the microbes in vitro under specific conditions and not all microbes are easily cultivable. This is followed by biochemical methods for identification which also require hours and sometimes days. Transport of the specimens under less than ideal conditions, prior use of antibiotics and small number of organisms are among the factors that render culture-based methods less reliable. Newer methods depend on amplification of nucleic acids followed by use of probes for identification. This mitigates the need for higher microbial load, presence of metabolically active viable organisms and shortens the time to reporting. These methods can be used to detect antibiotic resistance genes directly from the specimen and help direct targeted therapy. Since these methods will not fulfill all the diagnostic needs, a second approach is being used to shorten the time to identification after the organism has already grown. Mass spectrometry and bioinformatics are the tools making this possible. This review gives a historical perspective on diagnostic microbiology, discusses the pitfalls of current methodology and provides an overview of newer and future methods.

  17. Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry

    PubMed Central

    de Carvalho, Rosana Martins Ferreira; Mazzer, Nilton; Barbieri, Claudio Henrique

    2012-01-01

    Objective: To evaluate the intra- and inter-examiner reliability and reproducibility of goniometry in relation to photogrammetry of hand, comparing the angles of thumb abduction, PIP joint flexion of the II finger and MCP joint flexion of the V finger. Methods: The study included 30 volunteers, who were divided into three groups: one group of 10 physiotherapy students, one group of 10 physiotherapists, and a third group of 10 therapists of the hand. Each examiner performed the measurements on the same hand mold, using the goniometer followed by two photogrammetry software programs; CorelDraw® and ALCimagem®. Results: The results revealed that the groups and the methods proposed presented inter-examiner reliability, generally rated as excellent (ICC 0.998 I.C. 95% 0.995 - 0.999). In the intra-examiner evaluation, an excellent level of reliability was found between the three groups. In the comparison between groups for each angle and each method, no significant differences were found between the groups for most of the measurements. Conclusion: Goniometry and photogrammetry are reliable and reproducible methods for evaluating measurements of the hand. However, due to the lack of similar references, detailed studies are needed to define the normal parameters between the methods in the joints of the hand. Level of Evidence II, Diagnostic Study. PMID:24453594

  18. A 'difficult' insect allergy patient: reliable history of a sting, but all testing negative.

    PubMed

    Tracy, James M; Olsen, Jonathan A; Carlson, John

    2015-08-01

    Few conditions are as treatable as allergy to stinging insects, with venom immunotherapy (VIT) providing up to 98% protection to subsequent stings. The challenge with VIT is not in the treatment, but in the diagnosis. To offer VIT, one must determine a history of a systemic reaction to a stinging insect in conjunction with the presence venom-specific IgE. Current diagnostic methods, although sensitive and specific, are imperfect, and some newer testing options are not widely available. A conundrum occasionally faced is the patient with a reliable and compelling history of a systemic allergic reaction yet negative venom-specific testing. This diagnostic dilemma presents an opportunity to consider possible causes for this diagnostic challenge. Our evolving understanding of the role of occult mast cell disease may begin to help us understand this situation and develop appropriate management strategies. Venom-specific skin testing has long been the cornerstone of the evaluation of venom sensitivity and is often combined with in-vitro assays to add clarity, but even these occasionally may fall short. Exploring novel venom diagnostic testing methods may help to fill in some of the diagnostic gaps. Do currently available venom vaccines contain all the key venom species? Are there enough differences between insect species that we may simply be missing the relevant allergens? What is the significance of the antigenicity of carbohydrate moieties in venoms? What is the role of recombinant venom extracts? VIT is the definitive treatment for insect allergic individuals. To utilize VIT, identification of the relevant Hymenoptera is necessary. Unfortunately, this cannot always be accomplished. This deficiency can have several causes: a potential comorbid condition such as occult mast cell disease, limitations of currently available diagnostic resources, or testing vaccines with an insufficient coverage of relevant venom allergens. Exploring these potential causes may help to provide important insight into this important diagnostic conundrum. The use of a case report may help clarify this challenge.

  19. Validation of next generation sequencing technologies in comparison to current diagnostic gold standards for BRAF, EGFR and KRAS mutational analysis.

    PubMed

    McCourt, Clare M; McArt, Darragh G; Mills, Ken; Catherwood, Mark A; Maxwell, Perry; Waugh, David J; Hamilton, Peter; O'Sullivan, Joe M; Salto-Tellez, Manuel

    2013-01-01

    Next Generation Sequencing (NGS) has the potential of becoming an important tool in clinical diagnosis and therapeutic decision-making in oncology owing to its enhanced sensitivity in DNA mutation detection, fast-turnaround of samples in comparison to current gold standard methods and the potential to sequence a large number of cancer-driving genes at the one time. We aim to test the diagnostic accuracy of current NGS technology in the analysis of mutations that represent current standard-of-care, and its reliability to generate concomitant information on other key genes in human oncogenesis. Thirteen clinical samples (8 lung adenocarcinomas, 3 colon carcinomas and 2 malignant melanomas) already genotyped for EGFR, KRAS and BRAF mutations by current standard-of-care methods (Sanger Sequencing and q-PCR), were analysed for detection of mutations in the same three genes using two NGS platforms and an additional 43 genes with one of these platforms. The results were analysed using closed platform-specific proprietary bioinformatics software as well as open third party applications. Our results indicate that the existing format of the NGS technology performed well in detecting the clinically relevant mutations stated above but may not be reliable for a broader unsupervised analysis of the wider genome in its current design. Our study represents a diagnostically lead validation of the major strengths and weaknesses of this technology before consideration for diagnostic use.

  20. Proton exchange membrane fuel cell system diagnosis based on the signed directed graph method

    NASA Astrophysics Data System (ADS)

    Hua, Jianfeng; Lu, Languang; Ouyang, Minggao; Li, Jianqiu; Xu, Liangfei

    The fuel-cell powered bus is becoming the favored choice for electric vehicles because of its extended driving range, zero emissions, and high energy conversion efficiency when compared with battery-operated electric vehicles. In China, a demonstration program for the fuel cell bus fleet operated at the Beijing Olympics in 2008 and the Shanghai Expo in 2010. It is necessary to develop comprehensive proton exchange membrane fuel cell (PEMFC) diagnostic tools to increase the reliability of these systems. It is especially critical for fuel-cell city buses serving large numbers of passengers using public transportation. This paper presents a diagnostic analysis and implementation study based on the signed directed graph (SDG) method for the fuel-cell system. This diagnostic system was successfully implemented in the fuel-cell bus fleet at the Shanghai Expo in 2010.

  1. [METHODS OF MATHEMATICAL MODELING IN MORPHOLOGICAL DIAGNOSTICS OF CHORNOBYL FACTOR INFLUENCE ON PROSTATE GLAND OF COAL MINERS-- THE CHERNOBYL DISASTER FIGHTERS].

    PubMed

    Danylov, Iu V; Motkov, K V; Shevchenko, T I

    2014-01-01

    The morphometric estimation of parenchyma and stroma condition included the determination of 25 parameters in a prostate gland at 27 persons. The mathematical model of morphogenesis of prostate gland was created by Bayes' method. The method of differential diagnosis of a prostate gland tissues' changes conditioned by the influence of the Chernobyl factor and/or unfavorable terms of the work in underground coal mines have been worked out. Its practical use provides exactness and reliability of the diagnosis (not less than 95%), independence from the level of the qualification and personal experience of the doctor, allows us to unify, optimize and individualize the diagnostic algorithms, answer the requirements of evidential medicine.

  2. [Methods of mathematical modeling in morphological diagnostics of Chernobyl factor influence on the testes of coal miners of Donbas--the Chernobyl disaster fighters].

    PubMed

    Danylov, Iu V; Motkov, K V; Shevchenko, T I

    2014-01-01

    The morphometric estimation of parenchyma and stroma condition included the determination of 29 parameters in testicles at 27 persons. The mathematical model of morphogenesis of testicles was created by Bayes' method. The method of differential diagnosis of testicles tissues' changes conditioned by the influence of the Chernobyl factor and/or unfavorable terms of the work in underground coal mines have been worked out. Its practical use provides exactness and reliability of the diagnosis (not less than 95%), independence from the level of the qualification and personal experience of the doctor, allows us to unify, optimize and individualize the diagnostic algorithms, answer the requirements of evidential medicine.

  3. Journal: Efficient Hydrologic Tracer-Test Design for Tracer-Mass Estimation and Sample Collection Frequency, 1 Method Development

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...

  4. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9-12 Years Children.

    PubMed

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9-11 years were determined by two methods of CPBA and HPLC. Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes.

  5. Trichinella diagnostics and control: mandatory and best practices for ensuring food safety.

    PubMed

    Gajadhar, Alvin A; Pozio, Edoardo; Gamble, H Ray; Nöckler, Karsten; Maddox-Hyttel, Charlotte; Forbes, Lorry B; Vallée, Isabelle; Rossi, Patrizia; Marinculić, Albert; Boireau, Pascal

    2009-02-23

    Because of its role in human disease, there are increasing global requirements for reliable diagnostic and control methods for Trichinella in food animals to ensure meat safety and to facilitate trade. Consequently, there is a need for standardization of methods, programs, and best practices used in the control of Trichinella and trichinellosis. This review article describes the biology and epidemiology of Trichinella, and describes recommended test methods as well as modified and optimized procedures that are used in meat inspection programs. The use of ELISA for monitoring animals for infection in various porcine and equine pre- and post-slaughter programs, including farm or herd certification programs is also discussed. A brief review of the effectiveness of meat processing methods, such as freezing, cooking and preserving is provided. The importance of proper quality assurance and its application in all aspects of a Trichinella diagnostic system is emphasized. It includes the use of international quality standards, test validation and standardization, critical control points, laboratory accreditation, certification of analysts and proficiency testing. Also described, are the roles and locations of international and regional reference laboratories for trichinellosis where expert advice and support on research and diagnostics are available.

  6. Multi-hybrid instrumentations with smartphones and smartpads for innovative in-field and POC diagnostics

    NASA Astrophysics Data System (ADS)

    Hofmann, Dietrich; Dittrich, Paul-Gerald; Gärtner, Claudia; Klemm, Richard

    2013-03-01

    Aim of the paper is the orientation of research and development on a completely new approach to innovative in-field and point of care diagnostics in industry, biology and medicine. Central functional modules are smartphones and/or smart pads supplemented by additional hardware apps and software apps. Specific examples are given for numerous practical applications concerning optodigital instrumentations. The methodical classification distinguishes between different levels for combination of hardware apps (hwapps) and software apps (swapps) with smartphones and/or smartpads. These methods are fundamental enablers for the transformation from stationary conventional laboratory diagnostics into mobile innovative in-field and point of care diagnostics. The innovative approach opens so far untapped enormous markets due to the convenience, reliability and affordability of smartphone and/or smartpad instruments. A highly visible advantage of smartphones and/or smartpads is the huge number of their distribution, their worldwide connectivity via cloud services and the experienced capability of their users for practical operations.

  7. Point of Care- A Novel Approach to Periodontal Diagnosis-A Review

    PubMed Central

    Nayak, Prathibha Anand; Rana, Shivendra

    2017-01-01

    Periodontal disease, one of the prevalent oral diseases, is characterized by gingival inflammation and periodontal tissue destruction. Diagnosing this disease is challenging to the clinicians as the disease process is discontinuous and shows periods of exacerbation and remission. Traditional diagnostic methods basically tells about the past tissue destruction so new diagnostic methods are required which is able to detect the active state of the disease, determine the future progression and also estimates the response to the therapy, thereby helping in the better clinical management of the patient. Both saliva and Gingival crevicular fluid (GCF) are believed to be reliable medium to detect the biomarkers which plays a pivotal role in measuring the disease activity. Keeping these observations in mind rapid chairside tests are developed to diagnose periodontal disease called as Point of Care (POC) diagnostics which simplifies diagnosis and helps in improving the prognosis. This review article highlights about the biomarkers used in the diagnosis and throws light on the various available point of care diagnostic devices. PMID:28969294

  8. Brief Report: Interrater Reliability of Clinical Diagnosis and DSM-IV Criteria for Autistic Disorder: Results of the DSM-IV Autism Field Trial.

    ERIC Educational Resources Information Center

    Klin, Ami; Lang, Jason; Cicchetti, Domenic V.; Volkmar, Fred R.

    2000-01-01

    This study examined the inter-rater reliability of clinician-assigned diagnosis of autism using or not using the criteria specified in the Diagnostic and Statistical Manual IV (DSM-IV). For experienced raters there was little difference in reliability in the two conditions. However, a clinically significant improvement in diagnostic reliability…

  9. Schizoaffective disorder--an ongoing challenge for psychiatric nosology.

    PubMed

    Jäger, M; Haack, S; Becker, T; Frasch, K

    2011-04-01

    Schizoaffective disorder is a common diagnosis in mental health services. The present article aims to provide an overview of diagnostic reliability, symptomatology, outcome, neurobiology and treatment of schizoaffective disorder. Literature was identified by searches in "Medline" and "Cochrane Library". The diagnosis of schizoaffective disorder has a low reliability. There are marked differences between the current diagnostic systems. With respect to psychopathological symptoms, no clear boundaries were found between schizophrenia, schizoaffective disorder and affective disorders. Common neurobiological factors were found across the traditional diagnostic categories. Schizoaffective disorder according to ICD-10 criteria, but not to DSM-IV criteria, shows a more favorable outcome than schizophrenia. With regard to treatment, only a small and heterogeneous database exists. Due to the low reliability and questionable validity there is a substantial need for revision and unification of the current diagnostic concepts of schizoaffective disorder. If future diagnostic systems return to Kraepelin's dichotomous classification of non-organic psychosis or adopt a dimensional diagnostic approach, schizoaffective disorder will disappear from the psychiatric nomenclature. A nosological model with multiple diagnostic entities, however, would be compatible with retaining the diagnostic category of schizoaffective disorder. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  10. Measuring the impact of diagnostic decision support on the quality of clinical decision making: development of a reliable and valid composite score.

    PubMed

    Ramnarayan, Padmanabhan; Kapoor, Ritika R; Coren, Michael; Nanduri, Vasantha; Tomlinson, Amanda L; Taylor, Paul M; Wyatt, Jeremy C; Britto, Joseph F

    2003-01-01

    Few previous studies evaluating the benefits of diagnostic decision support systems have simultaneously measured changes in diagnostic quality and clinical management prompted by use of the system. This report describes a reliable and valid scoring technique to measure the quality of clinical decision plans in an acute medical setting, where diagnostic decision support tools might prove most useful. Sets of differential diagnoses and clinical management plans generated by 71 clinicians for six simulated cases, before and after decision support from a Web-based pediatric differential diagnostic tool (ISABEL), were used. A composite quality score was calculated separately for each diagnostic and management plan by considering the appropriateness value of each component diagnostic or management suggestion, a weighted sum of individual suggestion ratings, relevance of the entire plan, and its comprehensiveness. The reliability and validity (face, concurrent, construct, and content) of these two final scores were examined. Two hundred fifty-two diagnostic and 350 management suggestions were included in the interrater reliability analysis. There was good agreement between raters (intraclass correlation coefficient, 0.79 for diagnoses, and 0.72 for management). No counterintuitive scores were demonstrated on visual inspection of the sets. Content validity was verified by a consultation process with pediatricians. Both scores discriminated adequately between the plans of consultants and medical students and correlated well with clinicians' subjective opinions of overall plan quality (Spearman rho 0.65, p < 0.01). The diagnostic and management scores for each episode showed moderate correlation (r = 0.51). The scores described can be used as key outcome measures in a larger study to fully assess the value of diagnostic decision aids, such as the ISABEL system.

  11. Exploration of Analysis Methods for Diagnostic Imaging Tests: Problems with ROC AUC and Confidence Scores in CT Colonography

    PubMed Central

    Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.

    2014-01-01

    Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643

  12. Standardization of Epitopes for Human Chorionic Gonadotropin (hCG) Immunoassays.

    PubMed

    Berger, Peter; Lapthorn, Adrian J

    2016-01-01

    hCG and its variants are markers for pregnancy tests, pregnancyrelated complications, trophoblastic diseases, pre-natal screening of Down's syndrome and doping controls. Strong demands are imposed on diagnostic methods by the dynamic changes in the absolute and relative levels of hCG protein backbone variants and glycosylation isoforms in serum and urine during development of pregnancy or the progression/remission of tumors. Observed differences in the results between commercial diagnostic immunoassays reflect the unequal molar recognition of the different metabolic hCG variants, in particular the hCG beta core fragment (hCGβcf), by the diagnostic antibodies (Abs), as their epitopes are not standardized, and the fact that suboptimal hCG standards are used. To rapidly characterize Abs by their epitope recognition and specificity to evaluate their suitability for diagnostic immunoassays a procedure of comparative epitope mapping has been developed using epitope-defined reference Abs. Comparative epitope mapping of diagnostic Abs will provide the basis for the standardization of diagnostic antigenic domains/epitopes and consequently for improved reliability of hCG measurements. Diagnostic first line assays likely consist of pairs of Abs that recognize specific epitopes at the top of the neighboring peptide loops 1 and 3 (Ł1+3) and the cystine knot (ck) of hCGβ, respectively. In future, significant improvements of reliability, robustness and comparability of the results of immunoassays for complex glycoproteins such as hCG will be achieved by the use (i) of standardized diagnostic Abs against welldefined epitopes and (ii) of the new International Standards for hCG and for five hCG variants established by WHO, that are calibrated in molar (SI) units.

  13. Interobserver Reliability of the Berlin ARDS Definition and Strategies to Improve the Reliability of ARDS Diagnosis.

    PubMed

    Sjoding, Michael W; Hofer, Timothy P; Co, Ivan; Courey, Anthony; Cooke, Colin R; Iwashyna, Theodore J

    2018-02-01

    Failure to reliably diagnose ARDS may be a major driver of negative clinical trials and underrecognition and treatment in clinical practice. We sought to examine the interobserver reliability of the Berlin ARDS definition and examine strategies for improving the reliability of ARDS diagnosis. Two hundred five patients with hypoxic respiratory failure from four ICUs were reviewed independently by three clinicians, who evaluated whether patients had ARDS, the diagnostic confidence of the reviewers, whether patients met individual ARDS criteria, and the time when criteria were met. Interobserver reliability of an ARDS diagnosis was "moderate" (kappa = 0.50; 95% CI, 0.40-0.59). Sixty-seven percent of diagnostic disagreements between clinicians reviewing the same patient was explained by differences in how chest imaging studies were interpreted, with other ARDS criteria contributing less (identification of ARDS risk factor, 15%; cardiac edema/volume overload exclusion, 7%). Combining the independent reviews of three clinicians can increase reliability to "substantial" (kappa = 0.75; 95% CI, 0.68-0.80). When a clinician diagnosed ARDS with "high confidence," all other clinicians agreed with the diagnosis in 72% of reviews. There was close agreement between clinicians about the time when a patient met all ARDS criteria if ARDS developed within the first 48 hours of hospitalization (median difference, 5 hours). The reliability of the Berlin ARDS definition is moderate, driven primarily by differences in chest imaging interpretation. Combining independent reviews by multiple clinicians or improving methods to identify bilateral infiltrates on chest imaging are important strategies for improving the reliability of ARDS diagnosis. Copyright © 2017 American College of Chest Physicians. All rights reserved.

  14. Launch vehicle operations cost reduction through artificial intelligence techniques

    NASA Technical Reports Server (NTRS)

    Davis, Tom C., Jr.

    1988-01-01

    NASA's Kennedy Space Center has attempted to develop AI methods in order to reduce the cost of launch vehicle ground operations as well as to improve the reliability and safety of such operations. Attention is presently given to cost savings estimates for systems involving launch vehicle firing-room software and hardware real-time diagnostics, as well as the nature of configuration control and the real-time autonomous diagnostics of launch-processing systems by these means. Intelligent launch decisions and intelligent weather forecasting are additional applications of AI being considered.

  15. Electrophysiology of Cranial Nerve Testing: Trigeminal and Facial Nerves.

    PubMed

    Muzyka, Iryna M; Estephan, Bachir

    2018-01-01

    The clinical examination of the trigeminal and facial nerves provides significant diagnostic value, especially in the localization of lesions in disorders affecting the central and/or peripheral nervous system. The electrodiagnostic evaluation of these nerves and their pathways adds further accuracy and reliability to the diagnostic investigation and the localization process, especially when different testing methods are combined based on the clinical presentation and the electrophysiological findings. The diagnostic uniqueness of the trigeminal and facial nerves is their connectivity and their coparticipation in reflexes commonly used in clinical practice, namely the blink and corneal reflexes. The other reflexes used in the diagnostic process and lesion localization are very nerve specific and add more diagnostic yield to the workup of certain disorders of the nervous system. This article provides a review of commonly used electrodiagnostic studies and techniques in the evaluation and lesion localization of cranial nerves V and VII.

  16. Teaching DSM-III to clinicians. Some problems of the DSM-III system reducing reliability, using the diagnosis and classification of depressive disorders as an example.

    PubMed

    Malt, U F

    1986-01-01

    Experiences from teaching DSM-III to more than three hundred Norwegian psychiatrists and clinical psychologists suggest that reliable DSM-III diagnoses can be achieved within a few hours training with reference to the decision trees and the diagnostic criteria only. The diagnoses provided are more reliable than the corresponding ICD diagnoses which the participants were more familiar with. The three main sources of reduced reliability of the DSM-III diagnoses are related to: poor knowledge of the criteria which often is connected with failure of obtaining diagnostic key information during the clinical interview; unfamiliar concepts and vague or ambiguous criteria. The two first issues are related to the quality of the teaching of DSM-III. The third source of reduced reliability reflects unsolved validity issues. By using the classification of five affective case stories as examples, these sources of diagnostic pitfalls, reducing reliability and ways to overcome these problems when teaching the DSM-III system, are discussed. It is concluded that the DSM-III system of classification is easy to teach and that the system is superior to other classification systems available from a reliability point of view. The current version of the DSM-III system, however, partly owes a high degree of reliability to broad and heterogeneous diagnostic categories like the concept major depression, which may have questionable validity. Thus, the future revisions of the DSM-III system should, above all, address the issue of validity.

  17. Development and validation of a real-time PCR assay for the detection of Toxoplasma gondii DNA in animal and meat samples.

    PubMed

    Marino, Anna Maria Fausta; Percipalle, Maurizio; Giunta, Renato Paolo; Salvaggio, Antonio; Caracappa, Giulia; Alfonzetti, Tiziana; Aparo, Alessandra; Reale, Stefano

    2017-03-01

    We report a rapid and reliable method for the detection of Toxoplasma gondii in meat and animal tissues based on real-time polymerase chain reaction (PCR). Samples were collected from cattle, small ruminants, horses, and pigs raised or imported into Sicily, Italy. All DNA preparations were assayed by real-time PCR tests targeted to a 98-bp long fragment in the AF 529-bp repeat element and to the B1 gene using specific primers. Diagnostic sensitivity (100%), diagnostic specificity (100%), limit of detection (0.01 pg), efficiency (92-109%), and precision (mean coefficient of variation = 0.60%), repeatability (100%), reproducibility (100%), and robustness were evaluated using 240 DNA extracted samples (120 positives and 120 negative as per the OIE nested PCR method) from different matrices. Positive results were confirmed by the repetition of both real-time and nested PCR assays. Our study demonstrates the viability of a reliable, rapid, and specific real-time PCR on a large scale to monitor contamination with Toxoplasma cysts in meat and animal specimens. This validated method can be used for postmortem detection in domestic and wild animals and for food safety purposes.

  18. Use of the smartphone for end vertebra selection in scoliosis.

    PubMed

    Pepe, Murad; Kocadal, Onur; Iyigun, Abdullah; Gunes, Zafer; Aksahin, Ertugrul; Aktekin, Cem Nuri

    2017-03-01

    The aim of our study was to develop a smartphone-aided end vertebra selection method and to investigate its effectiveness in Cobb angle measurement. Twenty-nine adolescent idiopathic scoliosis patients' pre-operative posteroanterior scoliosis radiographs were used for end vertebra selection and Cobb angle measurement by standard method and smartphone-aided method. Measurements were performed by 7 examiners. The intraclass correlation coefficient was used to analyze selection and measurement reliability. Summary statistics of variance calculations were used to provide 95% prediction limits for the error in Cobb angle measurements. A paired 2-tailed t test was used to analyze end vertebra selection differences. Mean absolute Cobb angle difference was 3.6° for the manual method and 1.9° for the smartphone-aided method. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for Cobb angle measurement. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for end vertebra selection. But reliability values of manual set were lower than smartphone. Two observers selected significantly different end vertebra in their repeated selections for manual method. Smartphone-aided method for end vertebra selection and Cobb angle measurement showed excellent reliability. We can expect a reduction in measurement error rates with the widespread use of this method in clinical practice. Level III, Diagnostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  19. The Shoulder Objective Practical Assessment Tool: Evaluation of a New Tool Assessing Residents Learning in Diagnostic Shoulder Arthroscopy.

    PubMed

    Talbot, Christopher L; Holt, Edward M; Gooding, Benjamin W T; Tennent, Thomas D; Foden, Philip

    2015-08-01

    To design and validate an objective practical assessment tool for diagnostic shoulder arthroscopy that would provide residents with a method to evaluate their progression in this field of surgery and to identify specific learning needs. We designed and evaluated the shoulder Objective Practical Assessment Tool (OPAT). The shoulder OPAT was designed by us, and scoring domains were created using a Delphi process. The shoulder OPAT was trialed by members of the British Elbow & Shoulder Society Education Committee for internal consistency and ease of use before being offered to other trainers and residents. Inter-rater reliability and intrarater reliability were calculated. One hundred forty orthopaedic residents, of varying seniority, within 5 training regions in the United Kingdom, were questioned regarding the tool. A pilot study of 6 residents was undertaken. Internal consistency was 0.77 (standardized Cronbach α). Inter-rater reliability was 0.60, and intrarater reliability was 0.82. The Spearman correlation coefficient (r) between the global summary score for the shoulder OPAT and the current assessment tool used in postgraduate training for orthopaedic residents undertaking diagnostic shoulder arthroscopy equaled 0.74. Of the residents, 82% agreed or strongly agreed when asked if the shoulder OPAT would be a useful tool in monitoring progression and 72% agreed or strongly agreed with the introduction of the shoulder OPAT within the orthopaedic domain. This study shows that the shoulder OPAT fulfills several aspects of reliability and validity when tested. Despite the inter-rater reliability being 0.60, we believe that the shoulder OPAT has the potential to play a role alongside the current assessment tool in the training of orthopaedic residents. The shoulder OPAT can be used to assess residents during shoulder arthroscopy and has the potential for use in medical education, as well as arthroscopic skills training in the operating theater. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Test-retest reliability of a standardized psychiatric interview (DIS/CIDI).

    PubMed

    Semler, G; Wittchen, H U; Joschke, K; Zaudig, M; von Geiso, T; Kaiser, S; von Cranach, M; Pfister, H

    1987-01-01

    The reliability of DSM-III diagnoses using an expanded version of the Diagnostic Interview Schedule (DIS), called the Composite International Diagnostic Interview (CIDI), was evaluated by examining 60 psychiatric inpatients on a test-retest basis. Acceptable agreement coefficients of (kappa) 0.5 or above were found for all but two disorders: dysthymic disorder and generalized anxiety disorder. The subclassification of DSM-III affective disorders also revealed some discrepancies between the test and the retest interviews. When compared with results from earlier versions of the DIS, diagnostic reliability was found to have improved for the DSM-III anxiety disorders in particular. These improvements can possibly be attributed to some changes in the wording of the respective items of this section. Several reasons for lowered test-retest reliability are discussed.

  1. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    PubMed

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  2. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9–12 Years Children

    PubMed Central

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    Background: The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Methods: Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9–11 years were determined by two methods of CPBA and HPLC. Results: Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Conclusions: Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes. PMID:26330983

  3. Dirac R -matrix calculations for the electron-impact excitation of neutral tungsten providing noninvasive diagnostics for magnetic confinement fusion

    NASA Astrophysics Data System (ADS)

    Smyth, R. T.; Ballance, C. P.; Ramsbottom, C. A.; Johnson, C. A.; Ennis, D. A.; Loch, S. D.

    2018-05-01

    Neutral tungsten is the primary candidate as a wall material in the divertor region of the International Thermonuclear Experimental Reactor (ITER). The efficient operation of ITER depends heavily on precise atomic physics calculations for the determination of reliable erosion diagnostics, helping to characterize the influx of tungsten impurities into the core plasma. The following paper presents detailed calculations of the atomic structure of neutral tungsten using the multiconfigurational Dirac-Fock method, drawing comparisons with experimental measurements where available, and includes a critical assessment of existing atomic structure data. We investigate the electron-impact excitation of neutral tungsten using the Dirac R -matrix method, and by employing collisional-radiative models, we benchmark our results with recent Compact Toroidal Hybrid measurements. The resulting comparisons highlight alternative diagnostic lines to the widely used 400.88-nm line.

  4. Reliability of measuring sciatic and tibial nerve movement with diagnostic ultrasound during a neural mobilisation technique.

    PubMed

    Ellis, Richard; Hing, Wayne; Dilley, Andrew; McNair, Peter

    2008-08-01

    Diagnostic ultrasound provides a technique whereby real-time, in vivo analysis of peripheral nerve movement is possible. This study measured sciatic nerve movement during a "slider" neural mobilisation technique (ankle dorsiflexion/plantar flexion and cervical extension/flexion). Transverse and longitudinal movement was assessed from still ultrasound images and video sequences by using frame-by-frame cross-correlation software. Sciatic nerve movement was recorded in the transverse and longitudinal planes. For transverse movement, at the posterior midthigh (PMT) the mean value of lateral sciatic nerve movement was 3.54 mm (standard error of measurement [SEM] +/- 1.18 mm) compared with anterior-posterior/vertical (AP) movement of 1.61 mm (SEM +/- 0.78 mm). At the popliteal crease (PC) scanning location, lateral movement was 6.62 mm (SEM +/- 1.10 mm) compared with AP movement of 3.26 mm (SEM +/- 0.99 mm). Mean longitudinal sciatic nerve movement at the PMT was 3.47 mm (SEM +/- 0.79 mm; n = 27) compared with the PC of 5.22 mm (SEM +/- 0.05 mm; n = 3). The reliability of ultrasound measurement of transverse sciatic nerve movement was fair to excellent (Intraclass correlation coefficient [ICC] = 0.39-0.76) compared with excellent (ICC = 0.75) for analysis of longitudinal movement. Diagnostic ultrasound presents a reliable, noninvasive, real-time, in vivo method for analysis of sciatic nerve movement.

  5. Rasch Analysis of the Geriatric Depression Scale--Short Form

    ERIC Educational Resources Information Center

    Chiang, Karl S.; Green, Kathy E.; Cox, Enid O.

    2009-01-01

    Purpose: The purpose of this study was to examine scale dimensionality, reliability, invariance, targeting, continuity, cutoff scores, and diagnostic use of the Geriatric Depression Scale-Short Form (GDS-SF) over time with a sample of 177 English-speaking U.S. elders. Design and Methods: An item response theory, Rasch analysis, was conducted with…

  6. The diagnostic performance of dental maturity for identification of the circumpubertal growth phases: a meta-analysis.

    PubMed

    Perinetti, Giuseppe; Westphalen, Graziela H; Biasotto, Matteo; Salgarello, Stefano; Contardo, Luca

    2013-05-23

    The present meta-analysis initially evaluates the reliability of dental maturation in the identification of the circumpubertal growth phases, essentially for determining treatment timing in orthodontics. A literature survey was performed using the Medline, LILACS and SciELO databases, and the Cochrane Library (2000 to 2011). Studies of the correlation between dental and cervical vertebral maturation methods were considered. The mandibular canine, the first and second premolars, and the second molar were investigated. After the selection, six articles qualified for the final analysis. The overall correlation coefficients were all significant, ranging from 0.57 to 0.73. Five of these studies suggested the use of dental maturation as an indicator of the growth phase. However, the diagnostic performance analysis uncovered limited reliability only for the identification of the pre-pubertal growth phase. The determination of dental maturity for the assessment of treatment timing in orthodontics is not recommended.

  7. Cognitive anchoring on self-generated decisions reduces operator reliance on automated diagnostic aids.

    PubMed

    Madhavan, Poornima; Wiegmann, Douglas A

    2005-01-01

    Automation users often disagree with diagnostic aids that are imperfectly reliable. The extent to which users' agreements with an aid are anchored to their personal, self-generated diagnoses was explored. Participants (N = 75) performed 200 trials in which they diagnosed pump failures using an imperfectly reliable automated aid. One group (nonforced anchor, n = 50) provided diagnoses only after consulting the aid. Another group (forced anchor, n = 25) provided diagnoses both before and after receiving feedback from the aid. Within the nonforced anchor group, participants' self-reported tendency to prediagnose system failures significantly predicted their tendency to disagree with the aid, revealing a cognitive anchoring effect. Agreement rates of participants in the forced anchor group indicated that public commitment to a diagnosis did not strengthen this effect. Potential applications include the development of methods for reducing cognitive anchoring effects and improving automation utilization in high-risk domains.

  8. Interrater reliability of the new criteria for behavioral variant frontotemporal dementia.

    PubMed

    Lamarre, Amanda K; Rascovsky, Katya; Bostrom, Alan; Toofanian, Parnian; Wilkins, Sarah; Sha, Sharon J; Perry, David C; Miller, Zachary A; Naasan, Georges; Laforce, Robert; Hagen, Jayne; Takada, Leonel T; Tartaglia, Maria Carmela; Kang, Gail; Galasko, Douglas; Salmon, David P; Farias, Sarah Tomaszewski; Kaur, Berneet; Olichney, John M; Quitania Park, Lovingly; Mendez, Mario F; Tsai, Po-Heng; Teng, Edmond; Dickerson, Bradford Clark; Domoto-Reilly, Kimiko; McGinnis, Scott; Miller, Bruce L; Kramer, Joel H

    2013-05-21

    To evaluate the interrater reliability of the new International Behavioural Variant FTD Criteria Consortium (FTDC) criteria for behavioral variant frontotemporal dementia (bvFTD). Twenty standardized clinical case modules were developed for patients with a range of neurodegenerative diagnoses, including bvFTD, primary progressive aphasia (nonfluent, semantic, and logopenic variant), Alzheimer disease, and Lewy body dementia. Eighteen blinded raters reviewed the modules and 1) rated the presence or absence of core diagnostic features for the FTDC criteria, and 2) provided an overall diagnostic rating. Interrater reliability was determined by κ statistics for multiple raters with categorical ratings. The mean κ value for diagnostic agreement was 0.81 for possible bvFTD and 0.82 for probable bvFTD ("almost perfect agreement"). Interrater reliability for 4 of the 6 core features had "substantial" agreement (behavioral disinhibition, perseverative/compulsive, sympathy/empathy, hyperorality; κ = 0.61-0.80), whereas 2 had "moderate" agreement (apathy/inertia, neuropsychological; κ = 0.41-0.6). Clinician years of experience did not significantly influence rater accuracy. The FTDC criteria show promise for improving the diagnostic accuracy and reliability of clinicians and researchers. As disease-altering therapies are developed, accurate differential diagnosis between bvFTD and other neurodegenerative diseases will become increasingly important.

  9. The Impact of Measurement Noise in GPA Diagnostic Analysis of a Gas Turbine Engine

    NASA Astrophysics Data System (ADS)

    Ntantis, Efstratios L.; Li, Y. G.

    2013-12-01

    The performance diagnostic analysis of a gas turbine is accomplished by estimating a set of internal engine health parameters from available sensor measurements. No physical measuring instruments however can ever completely eliminate the presence of measurement uncertainties. Sensor measurements are often distorted by noise and bias leading to inaccurate estimation results. This paper explores the impact of measurement noise on Gas Turbine GPA analysis. The analysis is demonstrated with a test case where gas turbine performance simulation and diagnostics code TURBOMATCH is used to build a performance model of a model engine similar to Rolls-Royce Trent 500 turbofan engine, and carry out the diagnostic analysis with the presence of different levels of measurement noise. Conclusively, to improve the reliability of the diagnostic results, a statistical analysis of the data scattering caused by sensor uncertainties is made. The diagnostic tool used to deal with the statistical analysis of measurement noise impact is a model-based method utilizing a non-linear GPA.

  10. Validation of wet mount microscopy against Trichomonas culture among women of reproductive age group in Western province, Sri Lanka.

    PubMed

    Banneheke, H; Fernandopulle, R; Gunasekara, U; Barua, A; Fernando, N; Wickremasinghe, R

    2015-06-01

    Wet mount microscopy is the most commonly used diagnostic method for trichomoniasis in clinical diagnostic services all over the world including Sri Lanka due to its availability, simplicity and is relatively inexpensive. However, Trichomonas culture and PCR are the gold standard tests. Unfortunately, neither the culture nor PCR is available for the diagnosis of trichomoniasis in Sri Lanka. Thus, it is important to validate the wet mount microscopy as it is the only available diagnostic test and has not been validated to date in Sri Lanka. The objective was to evaluate the validity and reliability of wet mount microscopy against gold standard Trichomonas culture among clinic based population of reproductive age group women in Western province, Sri Lanka. Women attending hospital and institutional based clinics were enrolled. They were interviewed and high vaginal swabs were taken for laboratory diagnosis by culture and wet mount microscopy. There were 601 participants in the age group of 15-45 years. Wet mount microscopy showed 68% sensitivity, 100% specificity, 100% positive (PPV) and 98% negative predictive values (NPV) (P=0.001, kappa=0.803) respectively against the gold standard culture. The area under the ROC curve was 0.840. Sensitivity of wet mount microscopy is low. However it has high validity and reliability as a specific diagnostic test for trichomoniasis. If it is to be used among women of reproductive age group in Western province, Sri Lanka, a culture method could be adopted as a second test to confirm the negative wet mount for symptomatic patients.

  11. Automated assessment of joint synovitis activity from medical ultrasound and power doppler examinations using image processing and machine learning methods.

    PubMed

    Cupek, Rafal; Ziębiński, Adam

    2016-01-01

    Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. This paper focus on a computer aided diagnostic system that was developed within joint Polish-Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner's experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner's experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an assessment of synovitis severity.

  12. Clinical assessment of effusion in knee osteoarthritis—A systematic review

    PubMed Central

    Maricar, Nasimah; Callaghan, Michael J.; Parkes, Matthew J.; Felson, David T.; O׳Neill, Terence W.

    2016-01-01

    Objective The aim of this systematic review was to determine the validity and inter- and intra-observer reliability of the assessment of knee joint effusion in osteoarthritis (OA) of the knee. Methods MEDLINE, Web of Knowledge, CINAHL, EMBASE, and AMED were searched from their inception to February 2015. Articles were included according to a priori defined criteria: samples containing participants with knee OA; prospective evaluation of clinical tests and assessments of knee effusion that included reliability, sensitivity, and specificity of these tests. Results A total of 10 publications were reviewed. Eight of these considered reliability and four on validity of clinical assessments against ultrasound effusion. It was not possible to undertake a meta-analysis of reliability or validity because of differences in study designs and the clinical tests. Intra-observer kappa agreement for visible swelling ranged from 0.37 (suprapatellar) to 1.0 (prepatellar); for bulge sign 0.47 and balloon sign 0.37. Inter-observer kappa agreement for visible swelling ranged from −0.02 (prepatellar) to 0.65 (infrapatellar), the balloon sign −0.11 to 0.82, patellar tap −0.02 to 0.75 and bulge sign kappa −0.04 to 0.14 or reliability coefficient 0.97. Reliability and diagnostic accuracy tended to be better in experienced observers. Very few data looked at performance of individual clinical tests with sensitivity ranging 18.2–85.7% and specificity 35.3–93.3%, both higher with larger effusions. Conclusion The majority of unstandardized clinical tests to assess joint effusion in knee OA had relatively low intra- and inter-observer reliability. There is some evidence experience improved reliability and diagnostic accuracy of tests. Currently there is insufficient evidence to recommend any particular test in clinical practice. PMID:26581486

  13. Actigraphy assessments of circadian sleep-wake cycles in the Vegetative and Minimally Conscious States

    PubMed Central

    2013-01-01

    Background The Vegetative and Minimally Conscious States (VS; MCS) are characterized by absent or highly disordered signs of awareness alongside preserved sleep-wake cycles. According to international diagnostic guidelines, sleep-wake cycles are assessed by means of observations of variable periods of eye-opening and eye-closure. However, there is little empirical evidence for true circadian sleep-wake cycling in these patients, and there have been no large-scale investigations of the validity of this diagnostic criterion. Methods We measured the circadian sleep-wake rhythms of 55 VS and MCS patients by means of wrist actigraphy, an indirect method that is highly correlated with polysomnographic estimates of sleeping/waking. Results Contrary to the diagnostic guidelines, a significant proportion of patients did not exhibit statistically reliable sleep-wake cycles. The circadian rhythms of VS patients were significantly more impaired than those of MCS patients, as were the circadian rhythms of patients with non-traumatic injuries relative to those with traumatic injuries. The reliability of the circadian rhythms were significantly predicted by the patients' levels of visual and motor functioning, consistent with the putative biological generators of these rhythms. Conclusions The high variability across diagnoses and etiologies highlights the need for improved guidelines for the assessment of sleep-wake cycles in VS and MCS, and advocates the use of actigraphy as an inexpensive and non-invasive alternative. PMID:23347467

  14. Clinical criteria for psychiatric diagnosis and DSM-III.

    PubMed

    Spitzer, R L; Endicott, J; Robins, E

    1975-11-01

    The authors identify the differences in formal inclusion and exclusion criteria used to classify patient data into diagnoses as the largest source of diagnostic unreliability in psychiatry. They describe the efforts that have been made to reduce these differences, particularly the specified criteria approach to defining diagnostic categories, which was developed for research purposes. On the basis of studies showing that the use of specified criteria increases the reliability of diagnostic judgments, they suggest that including such criteria in the next edition of APA's Diagnostic and Statistical Manual of Mental Disorders (DSM-III) would improve the reliability and validity of routine psychiatric diagnosis.

  15. Radiological interpretation of images displayed on tablet computers: a systematic review

    PubMed Central

    Armfield, N R; Smith, A C

    2015-01-01

    Objective: To review the published evidence and to determine if radiological diagnostic accuracy is compromised when images are displayed on a tablet computer and thereby inform practice on using tablet computers for radiological interpretation by on-call radiologists. Methods: We searched the PubMed and EMBASE databases for studies on the diagnostic accuracy or diagnostic reliability of images interpreted on tablet computers. Studies were screened for inclusion based on pre-determined inclusion and exclusion criteria. Studies were assessed for quality and risk of bias using Quality Appraisal of Diagnostic Reliability Studies or the revised Quality Assessment of Diagnostic Accuracy Studies tool. Treatment of studies was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Results: 11 studies met the inclusion criteria. 10 of these studies tested the Apple iPad® (Apple, Cupertino, CA). The included studies reported high sensitivity (84–98%), specificity (74–100%) and accuracy rates (98–100%) for radiological diagnosis. There was no statistically significant difference in accuracy between a tablet computer and a digital imaging and communication in medicine-calibrated control display. There was a near complete consensus from authors on the non-inferiority of diagnostic accuracy of images displayed on a tablet computer. All of the included studies were judged to be at risk of bias. Conclusion: Our findings suggest that the diagnostic accuracy of radiological interpretation is not compromised by using a tablet computer. This result is only relevant to the Apple iPad and to the modalities of CT, MRI and plain radiography. Advances in knowledge: The iPad may be appropriate for an on-call radiologist to use for radiological interpretation. PMID:25882691

  16. Non-invasive diagnostics of the maxillary and frontal sinuses based on diode laser gas spectroscopy.

    PubMed

    Lewander, Märta; Lindberg, Sven; Svensson, Tomas; Siemund, Roger; Svanberg, Katarina; Svanberg, Sune

    2012-03-01

    Suspected, but objectively absent, rhinosinusitis constitutes a major cause of visits to the doctor, high health care costs, and the over-prescription of antibiotics, contributing to the serious problem of resistant bacteria. This situation is largely due to a lack of reliable and widely applicable diagnostic methods. A novel method for the diagnosis of rhinosinusitis based on non-intrusive diode laser gas spectroscopy is presented. The technique is based on light absorption by free gas (oxygen and water vapour) inside the sinuses, and has the potential to be a complementary diagnostic tool in primary health care. The method was evaluated on 40 patients with suspected sinus problems, referred to the diagnostic radiology clinic for low-dose computed tomography (CT), which was used as the reference technique. The data obtained with the new laser-based method correlated well with the grading of opacification and ventilation using CT. The sensitivity and specificity were estimated to be 93% and 61%, respectively, for the maxillary sinuses, and 94% and 86%, respectively, for the frontal sinuses. Good reproducibility was shown. The laser-based technique presents real-time clinical data that correlate well to CT findings, while being non-intrusive and avoiding the use of ionizing radiation.

  17. Golden angle based scanning for robust corneal topography with OCT

    PubMed Central

    Wagner, Joerg; Goldblum, David; Cattin, Philippe C.

    2017-01-01

    Corneal topography allows the assessment of the cornea’s refractive power which is crucial for diagnostics and surgical planning. The use of optical coherence tomography (OCT) for corneal topography is still limited. One limitation is the susceptibility to disturbances like blinking of the eye. This can result in partially corrupted scans that cannot be evaluated using common methods. We present a new scanning method for reliable corneal topography from partial scans. Based on the golden angle, the method features a balanced scan point distribution which refines over measurement time and remains balanced when part of the scan is removed. The performance of the method is assessed numerically and by measurements of test surfaces. The results confirm that the method enables numerically well-conditioned and reliable corneal topography from partially corrupted scans and reduces the need for repeated measurements in case of abrupt disturbances. PMID:28270961

  18. Reliability in the DSM-III field trials: interview v case summary.

    PubMed

    Hyler, S E; Williams, J B; Spitzer, R L

    1982-11-01

    A study compared the reliability of psychiatric diagnoses obtained from the live interviews and from case summaries, on the same patients, by the same clinicians, using the same DSM-III diagnostic criteria. The results showed that the reliability of the major diagnostic classes of DSM-III was higher when diagnoses were made from live interviews than when they were made from case summaries. We conclude that diagnoses based on information contained in traditionally prepared case summaries may lead to an underestimation of the reliability of diagnoses made based on information collected during a "live" interview.

  19. The Rorschach Perceptual-Thinking Index (PTI): An Examination of Reliability, Validity, and Diagnostic Efficiency

    ERIC Educational Resources Information Center

    Hilsenroth, Mark J.; Eudell-Simmons, Erin M.; DeFife, Jared A.; Charnas, Jocelyn W.

    2007-01-01

    This study investigates the reliability, validity, and diagnostic efficiency of the Rorschach Perceptual-Thinking Index (PTI) in relation to the accurate identification of psychotic disorder (PTD) patients. The PTI is a revision of the Rorschach Schizophrenia Index (SCZI), designed to achieve several criteria, including an increase in the…

  20. Eating Disorder Diagnostic Scale: Additional Evidence of Reliability and Validity

    ERIC Educational Resources Information Center

    Stice, Eric; Fisher, Melissa; Martinez, Erin

    2004-01-01

    The authors conducted 4 studies investigating the reliability and validity of the Eating Disorder Diagnostic Scale (HDDS; E. Stice, C. F. Telch, & S. L. Rizvi, 2000), a brief self-report measure for diagnosing anorexia nervosa, bulimia nervosa, and binge eating disorder. Study 1 found that the HDDS showed criterion validity with interview-based…

  1. [Validation of the nutritional index in Mexican pre-teens with the sensitivity and specificity method].

    PubMed

    Saucedo-Molina, T J; Gómez-Peresmitré, G

    1998-01-01

    To determine the diagnostic validity of the nutritional index (NI) in a sample of Mexican preadolescents. A total of 256 preadolescents, between 10 and 12 years old, male and female, students from Mexico City, were used to establish the diagnostic validity of NI using the sensitivity and specificity method. The findings show that the conventional NI cut-off points showed good sensitivity and specificity for the diagnosis of low weight, normality and obesity but not for overweight. When the cut-off points of NI were normalized, the sensitivity, specificity and prediction potency values were more suitable in all categories. When working with preadolescents, it is better to use the new cut-off points of NI, to obtain more reliable diagnosis.

  2. Application of MALDI-TOF mass spectrometry in clinical diagnostic microbiology.

    PubMed

    De Carolis, Elena; Vella, Antonietta; Vaccaro, Luisa; Torelli, Riccardo; Spanu, Teresa; Fiori, Barbara; Posteraro, Brunella; Sanguinetti, Maurizio

    2014-09-12

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful technique for identification of microorganisms, changing the workflow of well-established laboratories so that its impact on microbiological diagnostics has been unparalleled. In comparison with conventional identification methods that rely on biochemical tests and require long incubation procedures, MALDI-TOF MS has the advantage of identifying bacteria and fungi directly from colonies grown on culture plates in a few minutes and with simple procedures. Numerous studies on different systems available demonstrate the reliability and accuracy of the method, and new frontiers have been explored besides microbial species level identification, such as direct identification of pathogens from positive blood cultures, subtyping, and drug susceptibility detection.

  3. The Role of Conventional Ultrasound in the Assessment of Thyroid Nodule in Erbil City

    ERIC Educational Resources Information Center

    Musa, Sarbast Ismail; Hanary, Salah Mohammad

    2016-01-01

    Background: Nodular thyroid disease is relatively common although thyroid cancer is rare. The aim of this study is to evaluate the advantage and reliability of conventional ultrasound in correlating sonographic characteristics of thyroid nodule with US-FNAC guided result as a diagnostic aid in thyroid nodule. Method: 111 patients were examined by…

  4. [Nodular toxoplasmosis as a diagnostic and therapeutic problem].

    PubMed

    Zaorski, P; Kozłowski, J

    1999-01-01

    Enlargement of lymph nodes of the neck, slightly elevated body temperature and discomfort are symptoms characteristic of many illnesses. One of these can be toxoplasmosis. Because the rarity of its occurrence, sometimes toxoplasmosis may be last to be recognized. In many cases absence of specific additional examination guidelines can contribute to several problems with correct diagnosis. At the present time, the most reliable sample analysis methods are the examination of levels of antibodies IgG and IgM, and the histopathological verification. The authors also indicate that varying therapeutic effects using prophilactic treatment and insufficient additional examination could lead to diagnostic problems.

  5. Updated ultrasound criteria for polycystic ovary syndrome: reliable thresholds for elevated follicle population and ovarian volume.

    PubMed

    Lujan, Marla E; Jarrett, Brittany Y; Brooks, Eric D; Reines, Jonathan K; Peppin, Andrew K; Muhn, Narry; Haider, Ehsan; Pierson, Roger A; Chizen, Donna R

    2013-05-01

    Do the ultrasonographic criteria for polycystic ovaries supported by the 2003 Rotterdam consensus adequately discriminate between the normal and polycystic ovary syndrome (PCOS) condition in light of recent advancements in imaging technology and reliable methods for estimating follicle populations in PCOS? Using newer ultrasound technology and a reliable grid system approach to count follicles, we concluded that a substantially higher threshold of follicle counts throughout the entire ovary (FNPO)-26 versus 12 follicles-is required to distinguish among women with PCOS and healthy women from the general population. The Rotterdam consensus defined the polycystic ovary as having 12 or more follicles, measuring between 2 and 9 mm (FNPO), and/or an ovarian volume (OV) >10 cm(3). Since their initial proposal in 2003, a heightened prevalence of polycystic ovaries has been described in healthy women with regular menstrual cycles, which has questioned the accuracy of these criteria and marginalized the specificity of polycystic ovaries as a diagnostic criterion for PCOS. A diagnostic test study was performed using cross-sectional data, collected from 2006 to 2011, from 168 women prospectively evaluated by transvaginal ultrasonography. Receiver operating characteristic (ROC) curve analyses were performed to determine the appropriate diagnostic thresholds for: (i) FNPO, (ii) follicle counts in a single cross section (FNPS) and (iii) OV. The levels of intra- and inter-observer reliability when five observers used the proposed criteria on 100 ultrasound cases were also determined. Ninety-eight women diagnosed with PCOS by the National Institutes of Health criteria as having both oligo-amenorrhea and hyperandrogenism and 70 healthy female volunteers recruited from the general population. Participants were evaluated by transvaginal ultrasonography at the Royal University Hospital within the Department of Obstetrics, Gynecology and Reproductive Sciences, University of Saskatchewan (Saskatoon, SK, Canada) and in the Division of Nutritional Sciences' Human Metabolic Research Unit, Cornell University (Ithaca, NY, USA). Diagnostic potential for PCOS was highest for FNPO (0.969), followed by FNPS (0.880) and OV (0.873) as judged by the area under the ROC curve. An FNPO threshold of 26 follicles had the best compromise between sensitivity (85%) and specificity (94%) when discriminating between controls and PCOS. Similarly, an FNPS threshold of nine follicles had a 69% sensitivity and 90% specificity, and an OV of 10 cm(3) had a 81% sensitivity and 84% specificity. Levels of intra-observer reliability were 0.81, 0.80 and 0.86 when assessing FNPO, FNPS and OV, respectively. Inter-observer reliability was 0.71, 0.72 and 0.82, respectively. Thresholds proposed by this study should be limited to use in women aged between 18 and 35 years. Polycystic ovarian morphology has excellent diagnostic potential for detecting PCOS. FNPO have better diagnostic potential and yield greater diagnostic confidence compared with assessments of FNPS or OV. Whenever possible, images throughout the entire ovary should be collected for the ultrasonographic evaluation of PCOS. This study was funded by Cornell University and fellowship awards from the Saskatchewan Health Research Foundation and Canadian Institutes of Health Research. The authors have no conflict of interests to disclose.

  6. Computer-Aided Diagnosis of Acute Lymphoblastic Leukaemia

    PubMed Central

    2018-01-01

    Leukaemia is a form of blood cancer which affects the white blood cells and damages the bone marrow. Usually complete blood count (CBC) and bone marrow aspiration are used to diagnose the acute lymphoblastic leukaemia. It can be a fatal disease if not diagnosed at the earlier stage. In practice, manual microscopic evaluation of stained sample slide is used for diagnosis of leukaemia. But manual diagnostic methods are time-consuming, less accurate, and prone to errors due to various human factors like stress, fatigue, and so forth. Therefore, different automated systems have been proposed to wrestle the glitches in the manual diagnostic methods. In recent past, some computer-aided leukaemia diagnosis methods are presented. These automated systems are fast, reliable, and accurate as compared to manual diagnosis methods. This paper presents review of computer-aided diagnosis systems regarding their methodologies that include enhancement, segmentation, feature extraction, classification, and accuracy. PMID:29681996

  7. Aircraft operability methods applied to space launch vehicles

    NASA Astrophysics Data System (ADS)

    Young, Douglas

    1997-01-01

    The commercial space launch market requirement for low vehicle operations costs necessitates the application of methods and technologies developed and proven for complex aircraft systems. The ``building in'' of reliability and maintainability, which is applied extensively in the aircraft industry, has yet to be applied to the maximum extent possible on launch vehicles. Use of vehicle system and structural health monitoring, automated ground systems and diagnostic design methods derived from aircraft applications support the goal of achieving low cost launch vehicle operations. Transforming these operability techniques to space applications where diagnostic effectiveness has significantly different metrics is critical to the success of future launch systems. These concepts will be discussed with reference to broad launch vehicle applicability. Lessons learned and techniques used in the adaptation of these methods will be outlined drawing from recent aircraft programs and implementation on phase 1 of the X-33/RLV technology development program.

  8. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability

    PubMed Central

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-01-01

    Background There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. Objectives To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. Patients and Methods A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Results Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. Conclusion For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee. PMID:24348599

  9. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    PubMed

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  10. Reliable Multi-Label Learning via Conformal Predictor and Random Forest for Syndrome Differentiation of Chronic Fatigue in Traditional Chinese Medicine

    PubMed Central

    Wang, Huazhen; Liu, Xin; Lv, Bing; Yang, Fan; Hong, Yanzhu

    2014-01-01

    Objective Chronic Fatigue (CF) still remains unclear about its etiology, pathophysiology, nomenclature and diagnostic criteria in the medical community. Traditional Chinese medicine (TCM) adopts a unique diagnostic method, namely ‘bian zheng lun zhi’ or syndrome differentiation, to diagnose the CF with a set of syndrome factors, which can be regarded as the Multi-Label Learning (MLL) problem in the machine learning literature. To obtain an effective and reliable diagnostic tool, we use Conformal Predictor (CP), Random Forest (RF) and Problem Transformation method (PT) for the syndrome differentiation of CF. Methods and Materials In this work, using PT method, CP-RF is extended to handle MLL problem. CP-RF applies RF to measure the confidence level (p-value) of each label being the true label, and then selects multiple labels whose p-values are larger than the pre-defined significance level as the region prediction. In this paper, we compare the proposed CP-RF with typical CP-NBC(Naïve Bayes Classifier), CP-KNN(K-Nearest Neighbors) and ML-KNN on CF dataset, which consists of 736 cases. Specifically, 95 symptoms are used to identify CF, and four syndrome factors are employed in the syndrome differentiation, including ‘spleen deficiency’, ‘heart deficiency’, ‘liver stagnation’ and ‘qi deficiency’. The Results CP-RF demonstrates an outstanding performance beyond CP-NBC, CP-KNN and ML-KNN under the general metrics of subset accuracy, hamming loss, one-error, coverage, ranking loss and average precision. Furthermore, the performance of CP-RF remains steady at the large scale of confidence levels from 80% to 100%, which indicates its robustness to the threshold determination. In addition, the confidence evaluation provided by CP is valid and well-calibrated. Conclusion CP-RF not only offers outstanding performance but also provides valid confidence evaluation for the CF syndrome differentiation. It would be well applicable to TCM practitioners and facilitate the utilities of objective, effective and reliable computer-based diagnosis tool. PMID:24918430

  11. SU-F-E-01: Pitfalls: Reliability and Performance of Diagnostic X-Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Behling, R

    2016-06-15

    Purpose: Performance and reliability of medical X-ray tubes for imaging are crucial from an ethical, clinical and economic perspective. This lecture will deliver insight into the aspects to consider during the decision making process to invest in X-ray imaging equipment. Outdated metric still hampers realistic product comparison. It is time to change this and to comply with latest standards, which consider current technology. Failure modes and ways to avoid down-time of the equipment shall be discussed. In view of the increasing number of interventional procedures and the hazards associated with ionizing radiation, toxic contrast agents, and the combination thereof, themore » aspect of system reliability is of paramount importance. Methods: A comprehensive picture of trends for different modalities (CT, angiography, general radiology) has been drawn and led to the development of novel X-ray tube technology. Results: Recent X-ray tubes feature enhanced reliability and unprecedented performance. Relevant metrics for product comparison still have to be implemented in practice. Conclusion: The speed of scientific and industrial development of new diagnostic and therapeutic X-ray sources remains tremendous. Still, users suffer from gaps between desire and reality in day-to-day diagnostic routine. X-ray sources are still limiting cutting-edge medical procedures. Side-effects of wear and tear, limitations of the clinical work flow, costs, the characteristics of the X-ray spectrum and others topics need to be further addressed. New applications and modalities, like detection-based color-resolved X-ray and phase-contrast / dark-field imaging will impact the course of new developments of X-ray sources. The author is employee of Royal Philips.« less

  12. Note: Additionally refined new possibilities of plasma probe diagnostics.

    PubMed

    Riaby, V A; Savinov, V P; Masherov, P E; Yakunin, V G

    2018-03-01

    In two previous Notes published in this journal, a method of measuring probe sheath thickness and ion mass was described using Langmuir probe diagnostics in low pressure xenon plasma close to Maxwellian substance. According to the first Note, this method includes two stages: (i) in a special experiment with known ion mass, the Bohm and Child-Langmuir-Boguslavsky (CLB) equations for cylindrical Langmuir probes used in this xenon plasma were solved jointly to determine the probe sheath thicknesses and Bohm coefficient C BCyl ≈ 1.13; and (ii) in a general experiment, with known C BCyl , the same equations could be solved to obtain the probe sheath thicknesses and the mean ion mass. In the second Note, the (i) stage of this method was refined: the results of the CLB probe sheath model application, which were termed "evaluations," were corrected using the step-front probe sheath model, which was closer to reality in the special experiment with the xenon plasma. This process resulted in a Bohm coefficient of C BCyl ≈ 1.23 for the cylindrical probe. In the present Note, corrected xenon plasma parameters without the influence of the bare probe protective shield were used for the (i) stage of this diagnostic method. This action also refined the Bohm coefficient, lowering it to C BCyl ≈ 0.745 for cylindrical probes. This advance makes the new diagnostics method more objective and reliable.

  13. Note: Additionally refined new possibilities of plasma probe diagnostics

    NASA Astrophysics Data System (ADS)

    Riaby, V. A.; Savinov, V. P.; Masherov, P. E.; Yakunin, V. G.

    2018-03-01

    In two previous Notes published in this journal, a method of measuring probe sheath thickness and ion mass was described using Langmuir probe diagnostics in low pressure xenon plasma close to Maxwellian substance. According to the first Note, this method includes two stages: (i) in a special experiment with known ion mass, the Bohm and Child-Langmuir-Boguslavsky (CLB) equations for cylindrical Langmuir probes used in this xenon plasma were solved jointly to determine the probe sheath thicknesses and Bohm coefficient CBCyl ≈ 1.13; and (ii) in a general experiment, with known CBCyl, the same equations could be solved to obtain the probe sheath thicknesses and the mean ion mass. In the second Note, the (i) stage of this method was refined: the results of the CLB probe sheath model application, which were termed "evaluations," were corrected using the step-front probe sheath model, which was closer to reality in the special experiment with the xenon plasma. This process resulted in a Bohm coefficient of CBCyl ≈ 1.23 for the cylindrical probe. In the present Note, corrected xenon plasma parameters without the influence of the bare probe protective shield were used for the (i) stage of this diagnostic method. This action also refined the Bohm coefficient, lowering it to CBCyl ≈ 0.745 for cylindrical probes. This advance makes the new diagnostics method more objective and reliable.

  14. Chagas disease diagnostic applications: present knowledge and future steps

    PubMed Central

    Balouz, Virginia; Agüero, Fernán; Buscaglia, Carlos A.

    2017-01-01

    Chagas disease, caused by the protozoan Trypanosoma cruzi, is a life-long and debilitating illness of major significance throughout Latin America, and an emergent threat to global public health. Being a neglected disease, the vast majority of Chagasic patients have limited access to proper diagnosis and treatment, and there is only a marginal investment into R&D for drug and vaccine development. In this context, identification of novel biomarkers able to transcend the current limits of diagnostic methods surfaces as a main priority in Chagas disease applied research. The expectation is that these novel biomarkers will provide reliable, reproducible and accurate results irrespective of the genetic background, infecting parasite strain, stage of disease, and clinical-associated features of Chagasic populations. In addition, they should be able to address other still unmet diagnostic needs, including early detection of congenital T. cruzi transmission, rapid assessment of treatment efficiency or failure, indication/prediction of disease progression and direct parasite typification in clinical samples. The lack of access of poor and neglected populations to essential diagnostics also stress the necessity of developing new methods operational in Point-of-Care (PoC) settings. In summary, emergent diagnostic tests integrating these novel and tailored tools should provide a significant impact on the effectiveness of current intervention schemes and on the clinical management of Chagasic patients. In this chapter, we discuss the present knowledge and possible future steps in Chagas disease diagnostic applications, as well as the opportunity provided by recent advances in high-throughput methods for biomarker discovery. PMID:28325368

  15. Genus- and species-level identification of dermatophyte fungi by surface-enhanced Raman spectroscopy.

    PubMed

    Witkowska, Evelin; Jagielski, Tomasz; Kamińska, Agnieszka

    2018-03-05

    This paper demonstrates that surface-enhanced Raman spectroscopy (SERS) coupled with principal component analysis (PCA) can serve as a fast and reliable technique for detection and identification of dermatophyte fungi at both genus and species level. Dermatophyte infections are the most common mycotic diseases worldwide, affecting a quarter of the human population. Currently, there is no optimal method for detection and identification of fungal diseases, as each has certain limitations. Here, for the first time, we have achieved with a high accuracy, differentiation of dermatophytes representing three major genera, i.e. Trichophyton, Microsporum, and Epidermophyton. Two first principal components (PC), namely PC-1 and PC-2, gave together 97% of total variance. Additionally, species-level identification within the Trichophyton genus has been performed. PC-1 and PC-2, which are the most diagnostically significant, explain 98% of the variance in the data obtained from spectra of: Trichophyton rubrum, Trichophyton menatgrophytes, Trichophyton interdigitale and Trichophyton tonsurans. This study offers a new diagnostic approach for the identification of dermatophytes. Being fast, reliable and cost-effective, it has the potential to be incorporated in the clinical practice to improve diagnostics of medically important fungi. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Genus- and species-level identification of dermatophyte fungi by surface-enhanced Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Witkowska, Evelin; Jagielski, Tomasz; Kamińska, Agnieszka

    2018-03-01

    This paper demonstrates that surface-enhanced Raman spectroscopy (SERS) coupled with principal component analysis (PCA) can serve as a fast and reliable technique for detection and identification of dermatophyte fungi at both genus and species level. Dermatophyte infections are the most common mycotic diseases worldwide, affecting a quarter of the human population. Currently, there is no optimal method for detection and identification of fungal diseases, as each has certain limitations. Here, for the first time, we have achieved with a high accuracy, differentiation of dermatophytes representing three major genera, i.e. Trichophyton, Microsporum, and Epidermophyton. Two first principal components (PC), namely PC-1 and PC-2, gave together 97% of total variance. Additionally, species-level identification within the Trichophyton genus has been performed. PC-1 and PC-2, which are the most diagnostically significant, explain 98% of the variance in the data obtained from spectra of: Trichophyton rubrum, Trichophyton menatgrophytes, Trichophyton interdigitale and Trichophyton tonsurans. This study offers a new diagnostic approach for the identification of dermatophytes. Being fast, reliable and cost-effective, it has the potential to be incorporated in the clinical practice to improve diagnostics of medically important fungi.

  17. Bench-to-bedside review: Challenges of diagnosis, care and prevention of central catheter-related bloodstream infections in children

    PubMed Central

    2013-01-01

    Central venous catheters (CVCs) are indispensable in modern pediatric medicine. CVCs provide secure vascular access, but are associated with a risk of severe complications, in particular bloodstream infection. We provide a review of the recent literature about the diagnostic and therapeutic challenges of catheter-related bloodstream infection (CRBSI) in children and its prevention. Variations in blood sampling and limitations in blood culturing interfere with accurate and timely diagnosis of CRBSI. Although novel molecular testing methods appear promising in overcoming some of the present diagnostic limitations of conventional blood sampling in children, they still need to solidly prove their accuracy and reliability in clinical practice. Standardized practices of catheter insertion and care remain the cornerstone of CRBSI prevention although their implementation in daily practice may be difficult. Technology such as CVC impregnation or catheter locking with antimicrobial substances has been shown less effective than anticipated. Despite encouraging results in CRBSI prevention among adults, the goal of zero infection in children is still not in range. More high-quality research is needed in the field of prevention, accurate and reliable diagnostic measures and effective treatment of CRBSI in children. PMID:24041298

  18. Psychological Autopsy Studies as Diagnostic Tools: Are they Methodologically Flawed?

    PubMed Central

    Hjelmeland, Heidi; Dieserud, Gudrun; Dyregrov, Kari; Knizek, Birthe L.; Leenaars, Antoon A.

    2012-01-01

    One of the most established “truths” in suicidology is that almost all (90 % or more) of those who kill themselves suffer from one or more mental disorders, and a causal link between the two is implied. Psychological autopsy (PA) studies constitute one main evidence base for this conclusion. However, there has been little reflection on the reliability and validity of this method. For example, psychiatric diagnoses are assigned to people who have died by suicide by interviewing a few of the relatives and/or friends, often many years after the suicide. In this article, we scrutinize PA studies with particular focus on the diagnostic process and demonstrate that they cannot constitute a valid evidence base for a strong relationship between mental disorders and suicide. We show that most questions asked to assign a diagnosis are impossible to answer reliably by proxies, and thus, one cannot validly make conclusions. Thus, as a diagnostic tool psychological autopsies should now be abandoned. Instead, we recommend qualitative approaches focusing on the understanding of suicide beyond mental disorders, where narratives from a relatively high number of informants around each suicide are systematically analyzed in terms of the informants’ relationships with the deceased. PMID:24563941

  19. Hierarchy and Psychometric Properties of ADHD Symptoms in Spanish Children: An Application of the Graded Response Model

    PubMed Central

    Arias, Victor B.; Nuñez, Daniel E.; Martínez-Molina, Agustín; Ponce, Fernando P.; Arias, Benito

    2016-01-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM) diagnostic criteria assume that the 18 symptoms carry the same weight in an Attention Deficit with Hyperactivity Disorder (ADHD) diagnosis and bear the same discriminatory capacity. However, it is reasonable to think that symptoms may differ in terms of severity and even in the reliability with they represent the disorder. To test this hypothesis, the aim of this study was to calibrate in a sample of Spanish children (age 4–7; n = 784) a scale for assessing the symptoms of ADHD proposed by Diagnostic and Statistical Manual of Mental Disorders, IV-TR within the framework of Item Response Theory. Samejima’s Graded Response Model was used as a method for estimating the item difficulty and discrimination parameters. The results showed that ADHD subscales (Attention Deficit and Hyperactivity / Impulsivity) had good psychometric properties and had also a good fit to the model. However, relevant differences between symptoms were observed at the level of severity, informativeness and reliability for the assessment of ADHD. This finding suggests that it would be useful to identify the symptoms that are more important than the others with regard to diagnosing ADHD. PMID:27736911

  20. Hierarchy and Psychometric Properties of ADHD Symptoms in Spanish Children: An Application of the Graded Response Model.

    PubMed

    Arias, Victor B; Nuñez, Daniel E; Martínez-Molina, Agustín; Ponce, Fernando P; Arias, Benito

    2016-01-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM) diagnostic criteria assume that the 18 symptoms carry the same weight in an Attention Deficit with Hyperactivity Disorder (ADHD) diagnosis and bear the same discriminatory capacity. However, it is reasonable to think that symptoms may differ in terms of severity and even in the reliability with they represent the disorder. To test this hypothesis, the aim of this study was to calibrate in a sample of Spanish children (age 4-7; n = 784) a scale for assessing the symptoms of ADHD proposed by Diagnostic and Statistical Manual of Mental Disorders, IV-TR within the framework of Item Response Theory. Samejima's Graded Response Model was used as a method for estimating the item difficulty and discrimination parameters. The results showed that ADHD subscales (Attention Deficit and Hyperactivity / Impulsivity) had good psychometric properties and had also a good fit to the model. However, relevant differences between symptoms were observed at the level of severity, informativeness and reliability for the assessment of ADHD. This finding suggests that it would be useful to identify the symptoms that are more important than the others with regard to diagnosing ADHD.

  1. Delirium diagnosis defined by cluster analysis of symptoms versus diagnosis by DSM and ICD criteria: diagnostic accuracy study.

    PubMed

    Sepulveda, Esteban; Franco, José G; Trzepacz, Paula T; Gaviria, Ana M; Meagher, David J; Palma, José; Viñuelas, Eva; Grau, Imma; Vilella, Elisabet; de Pablo, Joan

    2016-05-26

    Information on validity and reliability of delirium criteria is necessary for clinicians, researchers, and further developments of DSM or ICD. We compare four DSM and ICD delirium diagnostic criteria versions, which were developed by consensus of experts, with a phenomenology-based natural diagnosis delineated using cluster analysis of delirium features in a sample with a high prevalence of dementia. We also measured inter-rater reliability of each system when applied by two evaluators from distinct disciplines. Cross-sectional analysis of 200 consecutive patients admitted to a skilled nursing facility, independently assessed within 24-48 h after admission with the Delirium Rating Scale-Revised-98 (DRS-R98) and for DSM-III-R, DSM-IV, DSM-5, and ICD-10 criteria for delirium. Cluster analysis (CA) delineated natural delirium and nondelirium reference groups using DRS-R98 items and then diagnostic systems' performance were evaluated against the CA-defined groups using logistic regression and crosstabs for discriminant analysis (sensitivity, specificity, percentage of subjects correctly classified by each diagnostic system and their individual criteria, and performance for each system when excluding each individual criterion are reported). Kappa Index (K) was used to report inter-rater reliability for delirium diagnostic systems and their individual criteria. 117 (58.5 %) patients had preexisting dementia according to the Informant Questionnaire on Cognitive Decline in the Elderly. CA delineated 49 delirium subjects and 151 nondelirium. Against these CA groups, delirium diagnosis accuracy was highest using DSM-III-R (87.5 %) followed closely by DSM-IV (86.0 %), ICD-10 (85.5 %) and DSM-5 (84.5 %). ICD-10 had the highest specificity (96.0 %) but lowest sensitivity (53.1 %). DSM-III-R had the best sensitivity (81.6 %) and the best sensitivity-specificity balance. DSM-5 had the highest inter-rater reliability (K =0.73) while DSM-III-R criteria were the least reliable. Using our CA-defined, phenomenologically-based delirium designations as the reference standard, we found performance discordance among four diagnostic systems when tested in subjects where comorbid dementia was prevalent. The most complex diagnostic systems have higher accuracy and the newer DSM-5 have higher reliability. Our novel phenomenological approach to designing a delirium reference standard may be preferred to guide revisions of diagnostic systems in the future.

  2. [Lab-on-a-chip systems in the point-of-care diagnostics].

    PubMed

    Szabó, Barnabás; Borbíró, András; Fürjes, Péter

    2015-12-27

    The need in modern medicine for near-patient diagnostics being able to accelerate therapeutic decisions and possibly replacing laboratory measurements is significantly growing. Reliable and cost-effective bioanalytical measurement systems are required which - acting as a micro-laboratory - contain integrated biomolecular recognition, sensing, signal processing and complex microfluidic sample preparation modules. These micro- and nanofabricated Lab-on-a-chip systems open new perspectives in the diagnostic supply chain, since they are able even for quantitative, high-precision and immediate analysis of special disease specific molecular markers or their combinations from a single drop of sample. Accordingly, crucial requirements regarding the instruments and the analytical methods are the high selectivity, extremely low detection limit, short response time and integrability into the healthcare information networks. All these features can make the hierarchical examination chain shorten, and revolutionize laboratory diagnostics, evolving a brand new situation in therapeutic intervention.

  3. Automated Dermoscopy Image Analysis of Pigmented Skin Lesions

    PubMed Central

    Baldi, Alfonso; Quartulli, Marco; Murace, Raffaele; Dragonetti, Emanuele; Manganaro, Mario; Guerra, Oscar; Bizzi, Stefano

    2010-01-01

    Dermoscopy (dermatoscopy, epiluminescence microscopy) is a non-invasive diagnostic technique for the in vivo observation of pigmented skin lesions (PSLs), allowing a better visualization of surface and subsurface structures (from the epidermis to the papillary dermis). This diagnostic tool permits the recognition of morphologic structures not visible by the naked eye, thus opening a new dimension in the analysis of the clinical morphologic features of PSLs. In order to reduce the learning-curve of non-expert clinicians and to mitigate problems inherent in the reliability and reproducibility of the diagnostic criteria used in pattern analysis, several indicative methods based on diagnostic algorithms have been introduced in the last few years. Recently, numerous systems designed to provide computer-aided analysis of digital images obtained by dermoscopy have been reported in the literature. The goal of this article is to review these systems, focusing on the most recent approaches based on content-based image retrieval systems (CBIR). PMID:24281070

  4. Rapid and Accurate Behavioral Health Diagnostic Screening: Initial Validation Study of a Web-Based, Self-Report Tool (the SAGE-SR)

    PubMed Central

    Purcell, Susan E; Rhea, Karen; Maier, Philip; First, Michael; Zweede, Lisa; Sinisterra, Manuela; Nunn, M Brad; Austin, Marie-Paule; Brodey, Inger S

    2018-01-01

    Background The Structured Clinical Interview for DSM (SCID) is considered the gold standard assessment for accurate, reliable psychiatric diagnoses; however, because of its length, complexity, and training required, the SCID is rarely used outside of research. Objective This paper aims to describe the development and initial validation of a Web-based, self-report screening instrument (the Screening Assessment for Guiding Evaluation-Self-Report, SAGE-SR) based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) and the SCID-5-Clinician Version (CV) intended to make accurate, broad-based behavioral health diagnostic screening more accessible within clinical care. Methods First, study staff drafted approximately 1200 self-report items representing individual granular symptoms in the diagnostic criteria for the 8 primary SCID-CV modules. An expert panel iteratively reviewed, critiqued, and revised items. The resulting items were iteratively administered and revised through 3 rounds of cognitive interviewing with community mental health center participants. In the first 2 rounds, the SCID was also administered to participants to directly compare their Likert self-report and SCID responses. A second expert panel evaluated the final pool of items from cognitive interviewing and criteria in the DSM-5 to construct the SAGE-SR, a computerized adaptive instrument that uses branching logic from a screener section to administer appropriate follow-up questions to refine the differential diagnoses. The SAGE-SR was administered to healthy controls and outpatient mental health clinic clients to assess test duration and test-retest reliability. Cutoff scores for screening into follow-up diagnostic sections and criteria for inclusion of diagnoses in the differential diagnosis were evaluated. Results The expert panel reduced the initial 1200 test items to 664 items that panel members agreed collectively represented the SCID items from the 8 targeted modules and DSM criteria for the covered diagnoses. These 664 items were iteratively submitted to 3 rounds of cognitive interviewing with 50 community mental health center participants; the expert panel reviewed session summaries and agreed on a final set of 661 clear and concise self-report items representing the desired criteria in the DSM-5. The SAGE-SR constructed from this item pool took an average of 14 min to complete in a nonclinical sample versus 24 min in a clinical sample. Responses to individual items can be combined to generate DSM criteria endorsements and differential diagnoses, as well as provide indices of individual symptom severity. Preliminary measures of test-retest reliability in a small, nonclinical sample were promising, with good to excellent reliability for screener items in 11 of 13 diagnostic screening modules (intraclass correlation coefficient [ICC] or kappa coefficients ranging from .60 to .90), with mania achieving fair test-retest reliability (ICC=.50) and other substance use endorsed too infrequently for analysis. Conclusions The SAGE-SR is a computerized adaptive self-report instrument designed to provide rigorous differential diagnostic information to clinicians. PMID:29572204

  5. Development and Validation of a Smartphone Addiction Scale (SAS)

    PubMed Central

    Kwon, Min; Lee, Joon-Yeop; Won, Wang-Youn; Park, Jae-Woo; Min, Jung-Ah; Hahn, Changtae; Gu, Xinyu; Choi, Ji-Hye; Kim, Dai-Jin

    2013-01-01

    Objective The aim of this study was to develop a self-diagnostic scale that could distinguish smartphone addicts based on the Korean self-diagnostic program for Internet addiction (K-scale) and the smartphone's own features. In addition, the reliability and validity of the smartphone addiction scale (SAS) was demonstrated. Methods A total of 197 participants were selected from Nov. 2011 to Jan. 2012 to accomplish a set of questionnaires, including SAS, K-scale, modified Kimberly Young Internet addiction test (Y-scale), visual analogue scale (VAS), and substance dependence and abuse diagnosis of DSM-IV. There were 64 males and 133 females, with ages ranging from 18 to 53 years (M = 26.06; SD = 5.96). Factor analysis, internal-consistency test, t-test, ANOVA, and correlation analysis were conducted to verify the reliability and validity of SAS. Results Based on the factor analysis results, the subscale “disturbance of reality testing” was removed, and six factors were left. The internal consistency and concurrent validity of SAS were verified (Cronbach's alpha = 0.967). SAS and its subscales were significantly correlated with K-scale and Y-scale. The VAS of each factor also showed a significant correlation with each subscale. In addition, differences were found in the job (p<0.05), education (p<0.05), and self-reported smartphone addiction scores (p<0.001) in SAS. Conclusions This study developed the first scale of the smartphone addiction aspect of the diagnostic manual. This scale was proven to be relatively reliable and valid. PMID:23468893

  6. Evidence-based rules from family practice to inform family practice; the learning healthcare system case study on urinary tract infections.

    PubMed

    Soler, Jean K; Corrigan, Derek; Kazienko, Przemyslaw; Kajdanowicz, Tomasz; Danger, Roxana; Kulisiewicz, Marcin; Delaney, Brendan

    2015-05-16

    Analysis of encounter data relevant to the diagnostic process sourced from routine electronic medical record (EMR) databases represents a classic example of the concept of a learning healthcare system (LHS). By collecting International Classification of Primary Care (ICPC) coded EMR data as part of the Transition Project from Dutch and Maltese databases (using the EMR TransHIS), data mining algorithms can empirically quantify the relationships of all presenting reasons for encounter (RfEs) and recorded diagnostic outcomes. We have specifically looked at new episodes of care (EoC) for two urinary system infections: simple urinary tract infection (UTI, ICPC code: U71) and pyelonephritis (ICPC code: U70). Participating family doctors (FDs) recorded details of all their patient contacts in an EoC structure using the ICPC, including RfEs presented by the patient, and the FDs' diagnostic labels. The relationships between RfEs and episode titles were studied using probabilistic and data mining methods as part of the TRANSFoRm project. The Dutch data indicated that the presence of RfE's "Cystitis/Urinary Tract Infection", "Dysuria", "Fear of UTI", "Urinary frequency/urgency", "Haematuria", "Urine symptom/complaint, other" are all strong, reliable, predictors for the diagnosis "Cystitis/Urinary Tract Infection" . The Maltese data indicated that the presence of RfE's "Dysuria", "Urinary frequency/urgency", "Haematuria" are all strong, reliable, predictors for the diagnosis "Cystitis/Urinary Tract Infection". The Dutch data indicated that the presence of RfE's "Flank/axilla symptom/complaint", "Dysuria", "Fever", "Cystitis/Urinary Tract Infection", "Abdominal pain/cramps general" are all strong, reliable, predictors for the diagnosis "Pyelonephritis" . The Maltese data set did not present any clinically and statistically significant predictors for pyelonephritis. We describe clinically and statistically significant diagnostic associations observed between UTIs and pyelonephritis presenting as a new problem in family practice, and all associated RfEs, and demonstrate that the significant diagnostic cues obtained are consistent with the literature. We conclude that it is possible to generate clinically meaningful diagnostic evidence from electronic sources of patient data.

  7. Methods for Quantitative Creatinine Determination.

    PubMed

    Moore, John F; Sharer, J Daniel

    2017-04-06

    Reliable measurement of creatinine is necessary to assess kidney function, and also to quantitate drug levels and diagnostic compounds in urine samples. The most commonly used methods are based on the Jaffe principal of alkaline creatinine-picric acid complex color formation. However, other compounds commonly found in serum and urine may interfere with Jaffe creatinine measurements. Therefore, many laboratories have made modifications to the basic method to remove or account for these interfering substances. This appendix will summarize the basic Jaffe method, as well as a modified, automated version. Also described is a high performance liquid chromatography (HPLC) method that separates creatinine from contaminants prior to direct quantification by UV absorption. Lastly, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that uses stable isotope dilution to reliably quantify creatinine in any sample. This last approach has been recommended by experts in the field as a means to standardize all quantitative creatinine methods against an accepted reference. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  8. Integrating multiple fitting regression and Bayes decision for cancer diagnosis with transcriptomic data from tumor-educated blood platelets.

    PubMed

    Huang, Guangzao; Yuan, Mingshun; Chen, Moliang; Li, Lei; You, Wenjie; Li, Hanjie; Cai, James J; Ji, Guoli

    2017-10-07

    The application of machine learning in cancer diagnostics has shown great promise and is of importance in clinic settings. Here we consider applying machine learning methods to transcriptomic data derived from tumor-educated platelets (TEPs) from individuals with different types of cancer. We aim to define a reliability measure for diagnostic purposes to increase the potential for facilitating personalized treatments. To this end, we present a novel classification method called MFRB (for Multiple Fitting Regression and Bayes decision), which integrates the process of multiple fitting regression (MFR) with Bayes decision theory. MFR is first used to map multidimensional features of the transcriptomic data into a one-dimensional feature. The probability density function of each class in the mapped space is then adjusted using the Gaussian probability density function. Finally, the Bayes decision theory is used to build a probabilistic classifier with the estimated probability density functions. The output of MFRB can be used to determine which class a sample belongs to, as well as to assign a reliability measure for a given class. The classical support vector machine (SVM) and probabilistic SVM (PSVM) are used to evaluate the performance of the proposed method with simulated and real TEP datasets. Our results indicate that the proposed MFRB method achieves the best performance compared to SVM and PSVM, mainly due to its strong generalization ability for limited, imbalanced, and noisy data.

  9. Candida bloodstream infection: a clinical microbiology laboratory perspective.

    PubMed

    Pongrácz, Júlia; Kristóf, Katalin

    2014-09-01

    The incidence of Candida bloodstream infection (BSI) has been on the rise in several countries worldwide. Species distribution is changing; an increase in the percentage of non-albicans species, mainly fluconazole non-susceptible C. glabrata was reported. Existing microbiology diagnostic methods lack sensitivity, and new methods need to be developed or further evaluation for routine application is necessary. Although reliable, standardized methods for antifungal susceptibility testing are available, the determination of clinical breakpoints remains challenging. Correct species identification is important and provides information on the intrinsic susceptibility profile of the isolate. Currently, acquired resistance in clinical Candida isolates is rare, but reports indicate that it could be an issue in the future. The role of the clinical microbiology laboratory is to isolate and correctly identify the infective agent and provide relevant and reliable susceptibility data as soon as possible to guide antifungal therapy.

  10. Reliability of diagnosis and clinical efficacy of visceral osteopathy: a systematic review.

    PubMed

    Guillaud, Albin; Darbois, Nelly; Monvoisin, Richard; Pinsault, Nicolas

    2018-02-17

    In 2010, the World Health Organization published benchmarks for training in osteopathy in which osteopathic visceral techniques are included. The purpose of this study was to identify and critically appraise the scientific literature concerning the reliability of diagnosis and the clinical efficacy of techniques used in visceral osteopathy. Databases MEDLINE, OSTMED.DR, the Cochrane Library, Osteopathic Research Web, Google Scholar, Journal of American Osteopathic Association (JAOA) website, International Journal of Osteopathic Medicine (IJOM) website, and the catalog of Académie d'ostéopathie de France website were searched through December 2017. Only inter-rater reliability studies including at least two raters or the intra-rater reliability studies including at least two assessments by the same rater were included. For efficacy studies, only randomized-controlled-trials (RCT) or crossover studies on unhealthy subjects (any condition, duration and outcome) were included. Risk of bias was determined using a modified version of the quality appraisal tool for studies of diagnostic reliability (QAREL) in reliability studies. For the efficacy studies, the Cochrane risk of bias tool was used to assess their methodological design. Two authors performed data extraction and analysis. Eight reliability studies and six efficacy studies were included. The analysis of reliability studies shows that the diagnostic techniques used in visceral osteopathy are unreliable. Regarding efficacy studies, the least biased study shows no significant difference for the main outcome. The main risks of bias found in the included studies were due to the absence of blinding of the examiners, an unsuitable statistical method or an absence of primary study outcome. The results of the systematic review lead us to conclude that well-conducted and sound evidence on the reliability and the efficacy of techniques in visceral osteopathy is absent. The review is registered PROSPERO 12th of December 2016. Registration number is CRD4201605286 .

  11. Develop Advanced Nonlinear Signal Analysis Topographical Mapping System

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1997-01-01

    During the development of the SSME, a hierarchy of advanced signal analysis techniques for mechanical signature analysis has been developed by NASA and AI Signal Research Inc. (ASRI) to improve the safety and reliability for Space Shuttle operations. These techniques can process and identify intelligent information hidden in a measured signal which is often unidentifiable using conventional signal analysis methods. Currently, due to the highly interactive processing requirements and the volume of dynamic data involved, detailed diagnostic analysis is being performed manually which requires immense man-hours with extensive human interface. To overcome this manual process, NASA implemented this program to develop an Advanced nonlinear signal Analysis Topographical Mapping System (ATMS) to provide automatic/unsupervised engine diagnostic capabilities. The ATMS will utilize a rule-based Clips expert system to supervise a hierarchy of diagnostic signature analysis techniques in the Advanced Signal Analysis Library (ASAL). ASAL will perform automatic signal processing, archiving, and anomaly detection/identification tasks in order to provide an intelligent and fully automated engine diagnostic capability. The ATMS has been successfully developed under this contract. In summary, the program objectives to design, develop, test and conduct performance evaluation for an automated engine diagnostic system have been successfully achieved. Software implementation of the entire ATMS system on MSFC's OISPS computer has been completed. The significance of the ATMS developed under this program is attributed to the fully automated coherence analysis capability for anomaly detection and identification which can greatly enhance the power and reliability of engine diagnostic evaluation. The results have demonstrated that ATMS can significantly save time and man-hours in performing engine test/flight data analysis and performance evaluation of large volumes of dynamic test data.

  12. Research to Establish the Validity, Reliability, and Clinical Utility of a Comprehensive Language Assessment of Mandarin

    ERIC Educational Resources Information Center

    Liu, Xueman Lucy; de Villiers, Jill; Ning, Chunyan; Rolfhus, Eric; Hutchings, Teresa; Lee, Wendy; Jiang, Fan; Zhang, Yi Wen

    2017-01-01

    Purpose: With no existing gold standard for comparison, challenges arise for establishing the validity of a new standardized Mandarin language assessment normed in mainland China. Method: A new assessment, Diagnostic Receptive and Expressive Assessment of Mandarin (DREAM), was normed with a stratified sample of 969 children ages 2;6 (years;months)…

  13. Embedded Diagnostic/Prognostic Reasoning and Information Continuity for Improved Avionics Maintenance

    DTIC Science & Technology

    2006-01-01

    enabling technologies such as built-in-test, advanced health monitoring algorithms, reliability and component aging models, prognostics methods, and...deployment and acceptance. This framework and vision is consistent with the onboard PHM ( Prognostic and Health Management) as well as advanced... monitored . In addition to the prognostic forecasting capabilities provided by monitoring system power, multiple confounding errors by electronic

  14. Cost analysis of breast cancer diagnostic assessment programs.

    PubMed

    Honein-AbouHaidar, G N; Hoch, J S; Dobrow, M J; Stuart-McEwan, T; McCready, D R; Gagliardi, A R

    2017-10-01

    Diagnostic assessment programs (daps) appear to improve the diagnosis of cancer, but evidence of their cost-effectiveness is lacking. Given that no earlier study used secondary financial data to estimate the cost of diagnostic tests in the province of Ontario, we explored how to use secondary financial data to retrieve the cost of key diagnostic test services in daps, and we tested the reliability of that cost-retrieving method with hospital-reported costs in preparation for future cost-effectiveness studies. We powered our sample at an alpha of 0.05, a power of 80%, and a margin of error of ±5%, and randomly selected a sample of eligible patients referred to a dap for suspected breast cancer during 1 January-31 December 2012. Confirmatory diagnostic tests received by each patient were identified in medical records. Canadian Classification of Health Intervention procedure codes were used to search the secondary financial data Web portal at the Ontario Case Costing Initiative for an estimate of the direct, indirect, and total costs of each test. The hospital-reported cost of each test received was obtained from the host-hospital's finance department. Descriptive statistics were used to calculate the cost of individual or group confirmatory diagnostic tests, and the Wilcoxon signed-rank test or the paired t-test was used to compare the Ontario Case Costing Initiative and hospital-reported costs. For the 191 identified patients with suspected breast cancer, the estimated total cost of $72,195.50 was not significantly different from the hospital-reported total cost of $72,035.52 ( p = 0.24). Costs differed significantly when multiple tests to confirm the diagnosis were completed during one patient visit and when confirmatory tests reported in hospital data and in medical records were discrepant. The additional estimated cost for non-salaried physicians delivering diagnostic services was $28,387.50. It was feasible to use secondary financial data to retrieve the cost of key diagnostic tests in a breast cancer dap and to compare the reliability of the costs obtained by that estimation method with hospital-reported costs. We identified the strengths and challenges of each approach. Lessons learned from this study have to be taken into consideration in future cost-effectiveness studies.

  15. A decision-tree approach to the assessment of posttraumatic stress disorder: Engineering empirically rigorous and ecologically valid assessment measures.

    PubMed

    Stewart, Regan W; Tuerk, Peter W; Metzger, Isha W; Davidson, Tatiana M; Young, John

    2016-02-01

    Structured diagnostic interviews are widely considered to be the optimal method of assessing symptoms of posttraumatic stress; however, few clinicians report using structured assessments to guide clinical practice. One commonly cited impediment to these assessment approaches is the amount of time required for test administration and interpretation. Empirically keyed methods to reduce the administration time of structured assessments may be a viable solution to increase the use of standardized and reliable diagnostic tools. Thus, the present research conducted an initial feasibility study using a sample of treatment-seeking military veterans (N = 1,517) to develop a truncated assessment protocol based on the Clinician-Administered Posttraumatic Stress Disorder (PTSD) Scale (CAPS). Decision-tree analysis was utilized to identify a subset of predictor variables among the CAPS items that were most predictive of a diagnosis of PTSD. The algorithm-driven, atheoretical sequence of questions reduced the number of items administered by more than 75% and classified the validation sample at 92% accuracy. These results demonstrated the feasibility of developing a protocol to assess PTSD in a way that imposes little assessment burden while still providing a reliable categorization. (c) 2016 APA, all rights reserved).

  16. [Optimal use of MRI mammography from the economic viewpoint].

    PubMed

    Oellinger, H; Blohmer, J U; Siewert, C; Hadijuana, J; Gutberlet, M; Ehrenstein, T; Lichtenegger, W; Felix, R

    1998-01-01

    With the introduction of the contrast agent gadolinum DTPA there were hopes that "MRM" would prove to be the investigatory technique that would largely solve the problems of breast diagnostics. However, after the early years of acceptance, the new method of investigation became a subject of controversy. Nonetheless, MRM today occupies a recognized place in diagnostics for certain indications. It is still true, however, that reliable use of this procedure requires a great deal of experience, since there is a relatively large area of overlap between benign and malignant tumors. Further, the costs are significantly higher than those for conventional methods of investigation. New studies that have been conducted at the Charité, Campus Virchow Medical Center in Berlin, suggest that, if one takes the relevant indications into account, MRM can be economic and contribute significantly to cost reduction. Application of a newly developed software package has shown that the good discrimination in a suspect area resulting from contrast agent enhancement makes possible a reliable differentiation between malignant and benign tissue changes. A further result was that, when certain boundary conditions are satisfied, a contrast agent bolus of 0.1 mmol/kg BW is sufficient, making a double dose (0.2 mmol/kg BW) unnecessary.

  17. Comparison of PCR methods for the detection of genetic variants of carp edema virus.

    PubMed

    Adamek, Mikolaj; Matras, Marek; Jung-Schroers, Verena; Teitge, Felix; Heling, Max; Bergmann, Sven M; Reichert, Michal; Way, Keith; Stone, David M; Steinhagen, Dieter

    2017-09-20

    The infection of common carp and its ornamental variety, koi, with the carp edema virus (CEV) is often associated with the occurrence of a clinical disease called 'koi sleepy disease'. The disease may lead to high mortality in both koi and common carp populations. To prevent further spread of the infection and the disease, a reliable detection method for this virus is required. However, the high genetic variability of the CEV p4a gene used for PCR-based diagnostics could be a serious obstacle for successful and reliable detection of virus infection in field samples. By analysing 39 field samples from different geographical origins obtained from koi and farmed carp and from all 3 genogroups of CEV, using several recently available PCR protocols, we investigated which of the protocols would allow the detection of CEV from all known genogroups present in samples from Central European carp or koi populations. The comparison of 5 different PCR protocols showed that the PCR assays (both end-point and quantitative) developed in the Centre for Environment, Fisheries and Aquaculture Science exhibited the highest analytical inclusivity and diagnostic sensitivity. Currently, this makes them the most suitable protocols for detecting viruses from all known CEV genogroups.

  18. A simple sandwich ELISA (WELYSSA) for the detection of lyssavirus nucleocapsid in rabies suspected specimens using mouse monoclonal antibodies.

    PubMed

    Xu, Gelin; Weber, Patrick; Hu, Qiaoling; Xue, Honggang; Audry, Laurent; Li, Chengping; Wu, Jie; Bourhy, Herve

    2007-10-01

    Monoclonal antibody (MAb)-based capture enzyme-linked immunosorbent assays (ELISA) were developed for the diagnosis of rabies-suspect specimens. A combination of four mouse monoclonal antibodies directed against the rabies virus nucleocapsid was selected and used for the detection. The test was optimized and standardized so that maximum concordance could be maintained with the standard procedures of rabies diagnosis recommended by the WHO expert committee. Using prototype viruses from the different genotypes of lyssavirus and from various geographic origins and phylogenetic lineages, this paper presents a reliable, rapid and transferable diagnostic method, named WELYSSA that readily permits the detection of lyssaviruses belonging to the 7 genotypes of lyssavirus circulating in Europe, Africa, Asia and Oceania. The threshold of detection of lyssavirus nucleocapsids is low (0.8 ng/ml). With a panel of 1030 specimens received for rabies diagnostic testing, this test was found to be highly specific (0.999) and sensitive (0.970) when compared to other recommended rabies diagnostic methods.

  19. Minimal methylation classifier (MIMIC): A novel method for derivation and rapid diagnostic detection of disease-associated DNA methylation signatures.

    PubMed

    Schwalbe, E C; Hicks, D; Rafiee, G; Bashton, M; Gohlke, H; Enshaei, A; Potluri, S; Matthiesen, J; Mather, M; Taleongpong, P; Chaston, R; Silmon, A; Curtis, A; Lindsey, J C; Crosier, S; Smith, A J; Goschzik, T; Doz, F; Rutkowski, S; Lannering, B; Pietsch, T; Bailey, S; Williamson, D; Clifford, S C

    2017-10-18

    Rapid and reliable detection of disease-associated DNA methylation patterns has major potential to advance molecular diagnostics and underpin research investigations. We describe the development and validation of minimal methylation classifier (MIMIC), combining CpG signature design from genome-wide datasets, multiplex-PCR and detection by single-base extension and MALDI-TOF mass spectrometry, in a novel method to assess multi-locus DNA methylation profiles within routine clinically-applicable assays. We illustrate the application of MIMIC to successfully identify the methylation-dependent diagnostic molecular subgroups of medulloblastoma (the most common malignant childhood brain tumour), using scant/low-quality samples remaining from the most recently completed pan-European medulloblastoma clinical trial, refractory to analysis by conventional genome-wide DNA methylation analysis. Using this approach, we identify critical DNA methylation patterns from previously inaccessible cohorts, and reveal novel survival differences between the medulloblastoma disease subgroups with significant potential for clinical exploitation.

  20. The reliability of a quality appraisal tool for studies of diagnostic reliability (QAREL).

    PubMed

    Lucas, Nicholas; Macaskill, Petra; Irwig, Les; Moran, Robert; Rickards, Luke; Turner, Robin; Bogduk, Nikolai

    2013-09-09

    The aim of this project was to investigate the reliability of a new 11-item quality appraisal tool for studies of diagnostic reliability (QAREL). The tool was tested on studies reporting the reliability of any physical examination procedure. The reliability of physical examination is a challenging area to study given the complex testing procedures, the range of tests, and lack of procedural standardisation. Three reviewers used QAREL to independently rate 29 articles, comprising 30 studies, published during 2007. The articles were identified from a search of relevant databases using the following string: "Reproducibility of results (MeSH) OR reliability (t.w.) AND Physical examination (MeSH) OR physical examination (t.w.)." A total of 415 articles were retrieved and screened for inclusion. The reviewers undertook an independent trial assessment prior to data collection, followed by a general discussion about how to score each item. At no time did the reviewers discuss individual papers. Reliability was assessed for each item using multi-rater kappa (κ). Multi-rater reliability estimates ranged from κ = 0.27 to 0.92 across all items. Six items were recorded with good reliability (κ > 0.60), three with moderate reliability (κ = 0.41 - 0.60), and two with fair reliability (κ = 0.21 - 0.40). Raters found it difficult to agree about the spectrum of patients included in a study (Item 1) and the correct application and interpretation of the test (Item 10). In this study, we found that QAREL was a reliable assessment tool for studies of diagnostic reliability when raters agreed upon criteria for the interpretation of each item. Nine out of 11 items had good or moderate reliability, and two items achieved fair reliability. The heterogeneity in the tests included in this study may have resulted in an underestimation of the reliability of these two items. We discuss these and other factors that could affect our results and make recommendations for the use of QAREL.

  1. Reliability and Validity of a Procedure to Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    1990-01-01

    The reliability and validity of a procedure to measure diagnostic-reasoning and problem-solving skills taught in predoctoral orthodontic education were studied using 68 second year dental students. The procedure includes stimulus material and 33 multiple-choice items. It is a feasible way of assessing problem-solving skills in dentistry education…

  2. Reliability and Diagnostic Efficiency of the Diagnostic Inventory for Disharmony (DID) in Youths with Pervasive Developmental Disorder and Multiple Complex Developmental Disorder

    ERIC Educational Resources Information Center

    Xavier, Jean; Vannetzel, Leonard; Viaux, Sylvie; Leroy, Arthur; Plaza, Monique; Tordjman, Sylvie; Mille, Christian; Bursztejn, Claude; Cohen, David; Guile, Jean-Marc

    2011-01-01

    The Pervasive Developmental Disorder-Not Otherwise Specified (PDD-NOS) category is a psychopathological entity few have described and is poorly, and mainly negatively, defined by autism exclusion. In order to limit PDD-NOS heterogeneity, alternative clinical constructs have been developed. This study explored the reliability and the diagnostic…

  3. Fault diagnostic instrumentation design for environmental control and life support systems

    NASA Technical Reports Server (NTRS)

    Yang, P. Y.; You, K. C.; Wynveen, R. A.; Powell, J. D., Jr.

    1979-01-01

    As a development phase moves toward flight hardware, the system availability becomes an important design aspect which requires high reliability and maintainability. As part of continous development efforts, a program to evaluate, design, and demonstrate advanced instrumentation fault diagnostics was successfully completed. Fault tolerance designs for reliability and other instrumenation capabilities to increase maintainability were evaluated and studied.

  4. Reliability and validity of a semi-structured DSM-based diagnostic interview module for the assessment of Attention Deficit Hyperactivity Disorder in adult psychiatric outpatients.

    PubMed

    Gorlin, Eugenia I; Dalrymple, Kristy; Chelminski, Iwona; Zimmerman, Mark

    2016-08-30

    Despite growing recognition that the symptoms and functional impairments of Attention Deficit/Hyperactivity Disorder (ADHD) persist into adulthood, only a few psychometrically sound diagnostic measures have been developed for the assessment of ADHD in adults, and none have been validated for use in a broad treatment-seeking psychiatric sample. The current study presents the reliability and validity of a semi-structured DSM-based diagnostic interview module for ADHD, which was administered to 1194 adults presenting to an outpatient psychiatric practice. The module showed excellent internal consistency and interrater reliability, good convergent and discriminant validity (as indexed by relatively high correlations with self-report measures of ADHD and ADHD-related constructs and little or no correlation with other, non-ADHD symptom domains), and good construct validity (as indexed by significantly higher rates of psychosocial impairment and self-reported family history of ADHD in individuals who meet criteria for an ADHD diagnosis). This instrument is thus a reliable and valid diagnostic tool for the detection of ADHD in adults presenting for psychiatric evaluation and treatment. Published by Elsevier Ireland Ltd.

  5. Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, paranoid personality disorder diagnosis: a unitary or a two-dimensional construct?

    PubMed

    Falkum, Erik; Pedersen, Geir; Karterud, Sigmund

    2009-01-01

    This article examines reliability and validity aspects of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) paranoid personality disorder (PPD) diagnosis. Patients with personality disorders (n = 930) from the Norwegian network of psychotherapeutic day hospitals, of which 114 had PPD, were included in the study. Frequency distribution, chi(2), correlations, reliability statistics, exploratory, and confirmatory factor analyses were performed. The distribution of PPD criteria revealed no distinct boundary between patients with and without PPD. Diagnostic category membership was obtained in 37 of 64 theoretically possible ways. The PPD criteria formed a separate factor in a principal component analysis, whereas a confirmatory factor analysis indicated that the DSM-IV PPD construct consists of 2 separate dimensions as follows: suspiciousness and hostility. The reliability of the unitary PPD scale was only 0.70, probably partly due to the apparent 2-dimensionality of the construct. Persistent unwarranted doubts about the loyalty of friends had the highest diagnostic efficiency, whereas unwarranted accusations of infidelity of partner had particularly poor indicator properties. The reliability and validity of the unitary PPD construct may be questioned. The 2-dimensional PPD model should be further explored.

  6. Diagnosing delirium in critically ill children: Validity and reliability of the Pediatric Confusion Assessment Method for the Intensive Care Unit*

    PubMed Central

    Smith, Heidi A. B.; Boyd, Jenny; Fuchs, D. Catherine; Melvin, Kelly; Berry, Pamela; Shintani, Ayumi; Eden, Svetlana K.; Terrell, Michelle K.; Boswell, Tonya; Wolfram, Karen; Sopfe, Jenna; Barr, Frederick E.; Pandharipande, Pratik P.; Ely, E. Wesley

    2013-01-01

    Objective To validate a diagnostic instrument for pediatric delirium in critically ill children, both ventilated and nonventilated, that uses standardized, developmentally appropriate measurements. Design and Setting A prospective observational cohort study investigating the Pediatric Confusion Assessment Method for Intensive Care Unit (pCAM-ICU) patients in the pediatric medical, surgical, and cardiac intensive care unit of a university-based medical center. Patients A total of 68 pediatric critically ill patients, at least 5 years of age, were enrolled from July 1, 2008, to March 30, 2009. Interventions None. Measurements Criterion validity including sensitivity and specificity and interrater reliability were determined using daily delirium assessments with the pCAM-ICU by two critical care clinicians compared with delirium diagnosis by pediatric psychiatrists using Diagnostic and Statistical Manual, 4th Edition, Text Revision criteria. Results A total of 146 paired assessments were completed among 68 enrolled patients with a mean age of 12.2 yrs. Compared with the reference standard for diagnosing delirium, the pCAM-ICU demonstrated a sensitivity of 83% (95% confidence interval, 66–93%), a specificity of 99% (95% confidence interval, 95–100%), and a high interrater reliability (κ = 0.96; 95% confidence interval, 0.74–1.0). Conclusions The pCAM-ICU is a highly valid reliable instrument for the diagnosis of pediatric delirium in critically ill children chronologically and developmentally at least 5 yrs of age. Use of the pCAM-ICU may expedite diagnosis and consultation with neuropsychiatry specialists for treatment of pediatric delirium. In addition, the pCAM-ICU may provide a means for delirium monitoring in future epidemiologic and interventional studies in critically ill children. (Crit Care Med 2011; 39:150–157) PMID:20959783

  7. Diagnosing delirium in critically ill children: Validity and reliability of the Pediatric Confusion Assessment Method for the Intensive Care Unit.

    PubMed

    Smith, Heidi A B; Boyd, Jenny; Fuchs, D Catherine; Melvin, Kelly; Berry, Pamela; Shintani, Ayumi; Eden, Svetlana K; Terrell, Michelle K; Boswell, Tonya; Wolfram, Karen; Sopfe, Jenna; Barr, Frederick E; Pandharipande, Pratik P; Ely, E Wesley

    2011-01-01

    To validate a diagnostic instrument for pediatric delirium in critically ill children, both ventilated and nonventilated, that uses standardized, developmentally appropriate measurements. A prospective observational cohort study investigating the Pediatric Confusion Assessment Method for Intensive Care Unit (pCAM-ICU) patients in the pediatric medical, surgical, and cardiac intensive care unit of a university-based medical center. A total of 68 pediatric critically ill patients, at least 5 years of age, were enrolled from July 1, 2008, to March 30, 2009. None. Criterion validity including sensitivity and specificity and interrater reliability were determined using daily delirium assessments with the pCAM-ICU by two critical care clinicians compared with delirium diagnosis by pediatric psychiatrists using Diagnostic and Statistical Manual, 4th Edition, Text Revision criteria. A total of 146 paired assessments were completed among 68 enrolled patients with a mean age of 12.2 yrs. Compared with the reference standard for diagnosing delirium, the pCAM-ICU demonstrated a sensitivity of 83% (95% confidence interval, 66-93%), a specificity of 99% (95% confidence interval, 95-100%), and a high interrater reliability (κ = 0.96; 95% confidence interval, 0.74-1.0). The pCAM-ICU is a highly valid reliable instrument for the diagnosis of pediatric delirium in critically ill children chronologically and developmentally at least 5 yrs of age. Use of the pCAM-ICU may expedite diagnosis and consultation with neuropsychiatry specialists for treatment of pediatric delirium. In addition, the pCAM-ICU may provide a means for delirium monitoring in future epidemiologic and interventional studies in critically ill children.

  8. [Diagnosis of tropical malaria by express-methods].

    PubMed

    Popov, A F; Nikiforov, N D; Ivanis, V A; Barkun, S P; Sanin, B I; Fed'kina, L I

    2004-01-01

    An examination of a thick blood drop and of blood smear for the presence of plasmodia is a classic and indisputable diagnostic test for tropic malaria. However, express-methods, based on the immune-enzyme analysis, have been introduced into the health-care practice primarily in developing and underdeveloped countries. The diagnosis of tropic malaria by using the discussed methods enables, in the non-laboratory settings, a rapid and reliable detection of PI. falciparum in blood. This is important because an untimely diagnosis of tropic malaria increases the risk of the lethal outcome.

  9. Inter-rater reliability of twelve diagnostic systems of schizophrenia.

    PubMed

    Helmes, E; Landmark, J; Kazarian, S S

    1983-05-01

    The present and past symptomatology of 31 chronic schizophrenics was rated by four independent judges, two experienced clinical psychiatrists and two psychiatric residents, in a context more representative of actual clinical practice than most research studies. Ratings were made on 64 symptoms derived from 12 diagnostic systems, based on either live or videotaped interviews for present symptomatology and case records for past symptomatology. Inter-rater reliabilities were higher for present than for past symptoms, and in general did not approach those reported for highly trained raters. There were no differences between live and videotaped interviews. Diagnostic systems differed widely in rater agreement. The most consistent across both past and present symptomatology were the systems of Langfeldt, Schneider, and DSM-III, for which the level of reliability was consistent with other studies.

  10. Failure analysis of solid rocket apogee motors

    NASA Technical Reports Server (NTRS)

    Martin, P. J.

    1972-01-01

    The analysis followed five selected motors through initial design, development, test, qualification, manufacture, and final flight reports. An audit was conducted at the manufacturing plants to complement the literature search with firsthand observations of the current philosophies and practices that affect reliability of the motors. A second literature search emphasized acquisition of spacecraft and satellite data bearing on solid motor reliability. It was concluded that present practices at the plants yield highly reliable flight hardware. Reliability can be further improved by new developments of aft-end bonding and initiator/igniter nondestructive test methods, a safe/arm device, and an insulation formulation. Minimum diagnostic instrumentation is recommended for all motor flights. Surplus motors should be used in margin testing. Criteria should be established for pressure and zone curing. The motor contractor should be represented at launch. New design analyses should be made of stretched motors and spacecraft/motor pairs.

  11. Predicting diagnostic error in Radiology via eye-tracking and image analytics: Application in mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voisin, Sophie; Pinto, Frank M; Morin-Ducote, Garnetta

    2013-01-01

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels. Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from 4 Radiology residents and 2 breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADsmore » images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated. Results: Diagnostic error can be predicted reliably by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model (AUC=0.79). Personalized user modeling was far more accurate for the more experienced readers (average AUC of 0.837 0.029) than for the less experienced ones (average AUC of 0.667 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features. Conclusions: Diagnostic errors in mammography can be predicted reliably by leveraging the radiologists gaze behavior and image content.« less

  12. Evaluating Secondary Students' Scientific Reasoning in Genetics Using a Two-Tier Diagnostic Instrument

    NASA Astrophysics Data System (ADS)

    Tsui, Chi-Yan; Treagust, David

    2010-05-01

    While genetics has remained as one key topic in school science, it continues to be conceptually and linguistically difficult for students with the concomitant debates as to what should be taught in the age of biotechnology. This article documents the development and implementation of a two-tier multiple-choice instrument for diagnosing grades 10 and 12 students' understanding of genetics in terms of reasoning. The pretest and posttest forms of the diagnostic instrument were used alongside other methods in evaluating students' understanding of genetics in a case-based qualitative study on teaching and learning with multiple representations in three Western Australian secondary schools. Previous studies have shown that a two-tier diagnostic instrument is useful in probing students' understanding or misunderstanding of scientific concepts and ideas. The diagnostic instrument in this study was designed and then progressively refined, improved, and implemented to evaluate student understanding of genetics in three case schools. The final version of the instrument had Cronbach's alpha reliability of 0.75 and 0.64, respectively, for its pretest and the posttest forms when it was administered to a group of grade 12 students (n = 17). This two-tier diagnostic instrument complemented other qualitative data collection methods in this research in generating a more holistic picture of student conceptual learning of genetics in terms of scientific reasoning. Implications of the findings of this study using the diagnostic instrument are discussed.

  13. Fluorescence detection of dental calculus

    NASA Astrophysics Data System (ADS)

    Gonchukov, S.; Biryukova, T.; Sukhinina, A.; Vdovin, Yu

    2010-11-01

    This work is devoted to the optimization of fluorescence dental calculus diagnostics in optical spectrum. The optimal wavelengths for fluorescence excitation and registration are determined. Two spectral ranges 620 - 645 nm and 340 - 370 nm are the most convenient for supra- and subgingival calculus determination. The simple implementation of differential method free from the necessity of spectrometer using was investigated. Calculus detection reliability in the case of simple implementation is higher than in the case of spectra analysis at optimal wavelengths. The use of modulated excitation light and narrowband detection of informative signal allows us to decrease essentially its diagnostic intensity even in comparison with intensity of the low level laser dental therapy.

  14. Research on Thermodynamic Parameters of a Micro-Turbine for Standalone Cogeneration

    NASA Astrophysics Data System (ADS)

    Chekardovskiy, M. N.; Chekardovskiy, S. M.; Chekardovskaya, I. A.; Mihajlenko, A. I.

    2016-10-01

    In order to advance the heating and hot water systems in the Russian Federation we need to address the problem of introducing new sources of heat and electric energy. The paper overviews the relationship between the reliability, efficiency and diagnostic maintenance of the GMTU, the studies of rated and operating conditions of the GMTU, the development and improvement of methods for calculating rated and operating thermodynamic and diagnostic parameter of the unit. This resulted in developing a passport of thermodynamic parameters that can be compared to the parameters of the same units when they operate for the purpose of diagnosing their state.

  15. Patient Dose In Diagnostic Radiology: When & How?

    NASA Astrophysics Data System (ADS)

    Lassen, Margit; Gorson, Robert O.

    1980-08-01

    Different situations are discussed in which it is of value to know radiation dose to the patient in diagnostic radiology. Radiation dose to specific organs is determined using the Handbook on Organ Doses published by the Bureau of Radiological Health of the Food and Drug Administration; the method is applied to a specific case. In this example dose to an embryo is calculated in examinations involving both fluoroscopy and radiography. In another example dose is determined to a fetus in late pregnancy using tissue air ratios. Patient inquiries about radiation dose are discussed, and some answers are suggested. The reliability of dose calculations is examined.

  16. Systematic review and meta-analysis: rapid diagnostic tests versus placental histology, microscopy and PCR for malaria in pregnant women

    PubMed Central

    2011-01-01

    Background During pregnancy, malaria infection with Plasmodium falciparum or Plasmodium vivax is related to adverse maternal health and poor birth outcomes. Diagnosis of malaria, during pregnancy, is complicated by the absence or low parasite densities in peripheral blood. Diagnostic methods, other than microscopy, are needed for detection of placental malaria. Therefore, the diagnostic accuracy of rapid diagnostic tests (RDTs), detecting antigen, and molecular techniques (PCR), detecting DNA, for the diagnosis of Plasmodium infections in pregnancy was systematically reviewed. Methods MEDLINE, EMBASE and Web of Science were searched for studies assessing the diagnostic accuracy of RDTs, PCR, microscopy of peripheral and placental blood and placental histology for the detection of malaria infection (all species) in pregnant women. Results The results of 49 studies were analysed in metandi (Stata), of which the majority described P. falciparum infections. Although both placental and peripheral blood microscopy cannot reliably replace histology as a reference standard for placental P. falciparum infection, many studies compared RDTs and PCR to these tests. The proportion of microscopy positives in placental blood (sensitivity) detected by peripheral blood microscopy, RDTs and PCR are respectively 72% [95% CI 62-80], 81% [95% CI 55-93] and 94% [95% CI 86-98]. The proportion of placental blood microscopy negative women that were negative in peripheral blood microscopy, RDTs and PCR (specificity) are 98% [95% CI 95-99], 94% [95% CI 76-99] and 77% [95% CI 71-82]. Based on the current data, it was not possible to determine if the false positives in RDTs and PCR are caused by sequestered parasites in the placenta that are not detected by placental microscopy. Conclusion The findings suggest that RDTs and PCR may have good performance characteristics to serve as alternatives for the diagnosis of malaria in pregnancy, besides any other limitations and practical considerations concerning the use of these tests. Nevertheless, more studies with placental histology as reference test are urgently required to reliably determine the accuracy of RDTs and PCR for the diagnosis of placental malaria. P. vivax-infections have been neglected in diagnostic test accuracy studies of malaria in pregnancy. PMID:22035448

  17. Aggressive periodontitis: case definition and diagnostic criteria.

    PubMed

    Albandar, Jasim M

    2014-06-01

    Aggressive periodontitis is a destructive disease characterized by the following: the involvement of multiple teeth with a distinctive pattern of periodontal tissue loss; a high rate of disease progression; an early age of onset; and the absence of systemic diseases. In some patients periodontal tissue loss may commence before puberty, whereas in most patients the age of onset is during or somewhat after the circumpubertal period. Besides infection with specific microorganisms, a host predisposition seems to play a key role in the pathogenesis of aggressive periodontitis, as evidenced by the familial aggregation of the disease. In this article we review the historical background of the diagnostic criteria of aggressive periodontitis, present a contemporary case definition and describe the clinical parameters of the disease. At present, the diagnosis of aggressive periodontitis is achieved using case history, clinical examination and radiographic evaluation. The data gathered using these methods are prone to relatively high measurement errors. Besides, this diagnostic approach measures past disease history and may not reliably measure existing disease activity or accurately predict future tissue loss. A diagnosis is often made years after the onset of the disease, partly because current assessment methods detect established disease more readily and reliably than they detect incipient or initial lesions where the tissue loss is minimal and usually below the detection threshold of present examination methods. Future advancements in understanding the pathogenesis of this disease may contribute to an earlier diagnosis. Insofar, future case definitions may involve the identification of key etiologic and risk factors, combined with high-precision methodologies that enable the early detection of initial lesions. This may significantly enhance the predictive value of these tests and detect cases of aggressive periodontitis before significant tissue loss develops. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Assessing the reliability of microscopy and rapid diagnostic tests in malaria diagnosis in areas with varying parasite density among older children and adult patients in Nigeria.

    PubMed

    Ayogu, E E; Ukwe, C V; Nna, E O

    2016-01-01

    Current malaria control strategies are based on early diagnosis and appropriate treatment of malaria cases. The study aimed at comparing the performance of blood film microscopy and rapid diagnostic test (RDT) in Plasmodium falciparum detection in patients ≥6 years of age. A total of 154 consecutive pyretic patients aged 6-62 years were enrolled, sampled, and tested for malaria using RDT (first response) and microscopy by Giemsa staining. Genomic DNA was extracted after saponin hemolysis and nested polymerase chain reaction (PCR) was used to detect Plasmodium falciparum. The endpoints were sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Of the 154 patients, 80 (51.9%) had fever of ≥37.5°C. 106 (68.8%) were positive by First response® , 132 (85.7%) by microscopy, and 121 (78.6%) by PCR. The sensitivity, specificity, PPV, and NPV of first response compared to microscopic method were 82.2%, 100.0%, 100.0%, and 34.3%, respectively, while it was 75.4%, 75.0%, 95.3%, and 31.2%, respectively, when compared to PCR. The sensitivity, specificity, PPV, and NPV of the microscopic method compared to PCR were 92.3%, 50.0%, 90.91%, and 54.5%, respectively. There was a significant difference in the performance of RDT and film microscopy methods (P ≤ 0.05). Microscopy performed better and is more reliable than first response (RDT) in areas with low parasite density among patients ≥6 years of age. Rapid diagnostic tests could be useful in aareas with high parasite density as an alternative to smear microscopy.

  19. The IDEA Assessment Tool: Assessing the Reporting, Diagnostic Reasoning, and Decision-Making Skills Demonstrated in Medical Students' Hospital Admission Notes.

    PubMed

    Baker, Elizabeth A; Ledford, Cynthia H; Fogg, Louis; Way, David P; Park, Yoon Soo

    2015-01-01

    Construct: Clinical skills are used in the care of patients, including reporting, diagnostic reasoning, and decision-making skills. Written comprehensive new patient admission notes (H&Ps) are a ubiquitous part of student education but are underutilized in the assessment of clinical skills. The interpretive summary, differential diagnosis, explanation of reasoning, and alternatives (IDEA) assessment tool was developed to assess students' clinical skills using written comprehensive new patient admission notes. The validity evidence for assessment of clinical skills using clinical documentation following authentic patient encounters has not been well documented. Diagnostic justification tools and postencounter notes are described in the literature (1,2) but are based on standardized patient encounters. To our knowledge, the IDEA assessment tool is the first published tool that uses medical students' H&Ps to rate students' clinical skills. The IDEA assessment tool is a 15-item instrument that asks evaluators to rate students' reporting, diagnostic reasoning, and decision-making skills based on medical students' new patient admission notes. This study presents validity evidence in support of the IDEA assessment tool using Messick's unified framework, including content (theoretical framework), response process (interrater reliability), internal structure (factor analysis and internal-consistency reliability), and relationship to other variables. Validity evidence is based on results from four studies conducted between 2010 and 2013. First, the factor analysis (2010, n = 216) yielded a three-factor solution, measuring patient story, IDEA, and completeness, with reliabilities of .79, .88, and .79, respectively. Second, an initial interrater reliability study (2010) involving two raters demonstrated fair to moderate consensus (κ = .21-.56, ρ =.42-.79). Third, a second interrater reliability study (2011) with 22 trained raters also demonstrated fair to moderate agreement (intraclass correlations [ICCs] = .29-.67). There was moderate reliability for all three skill domains, including reporting skills (ICC = .53), diagnostic reasoning skills (ICC = .64), and decision-making skills (ICC = .63). Fourth, there was a significant correlation between IDEA rating scores (2010-2013) and final Internal Medicine clerkship grades (r = .24), 95% confidence interval (CI) [.15, .33]. The IDEA assessment tool is a novel tool with validity evidence to support its use in the assessment of students' reporting, diagnostic reasoning, and decision-making skills. The moderate reliability achieved supports formative or lower stakes summative uses rather than high-stakes summative judgments.

  20. Rolling element bearings diagnostics using the Symbolic Aggregate approXimation

    NASA Astrophysics Data System (ADS)

    Georgoulas, George; Karvelis, Petros; Loutas, Theodoros; Stylios, Chrysostomos D.

    2015-08-01

    Rolling element bearings are a very critical component in various engineering assets. Therefore it is of paramount importance the detection of possible faults, especially at an early stage, that may lead to unexpected interruptions of the production or worse, to severe accidents. This research work introduces a novel, in the field of bearing fault detection, method for the extraction of diagnostic representations of vibration recordings using the Symbolic Aggregate approXimation (SAX) framework and the related intelligent icons representation. SAX essentially transforms the original real valued time-series into a discrete one, which is then represented by a simple histogram form summarizing the occurrence of the chosen symbols/words. Vibration signals from healthy bearings and bearings with three different fault locations and with three different severity levels, as well as loading conditions, are analyzed. Considering the diagnostic problem as a classification one, the analyzed vibration signals and the resulting feature vectors feed simple classifiers achieving remarkably high classification accuracies. Moreover a sliding window scheme combined with a simple majority voting filter further increases the reliability and robustness of the diagnostic method. The results encourage the potential use of the proposed methodology for the diagnosis of bearing faults.

  1. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review.

    PubMed

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans; Søgaard, Karen

    2014-10-01

    The aims were to compile a schematic overview of clinical scapular assessment methods and critically appraise the methodological quality of the involved studies. A systematic, computer-assisted literature search using Medline, CINAHL, SportDiscus and EMBASE was performed from inception to October 2013. Reference lists in articles were also screened for publications. From 50 articles, 54 method names were identified and categorized into three groups: (1) Static positioning assessment (n = 19); (2) Semi-dynamic (n = 13); and (3) Dynamic functional assessment (n = 22). Fifteen studies were excluded for evaluation due to no/few clinimetric results, leaving 35 studies for evaluation. Graded according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN checklist), the methodological quality in the reliability and validity domains was "fair" (57%) to "poor" (43%), with only one study rated as "good". The reliability domain was most often investigated. Few of the assessment methods in the included studies that had "fair" or "good" measurement property ratings demonstrated acceptable results for both reliability and validity. We found a substantially larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general "fair" to "poor". None were examined for all three domains: (1) reliability; (2) validity; and (3) responsiveness. Observational evaluation systems and assessment of scapular upward rotation seem suitably evidence-based for clinical use. Future studies should test and improve the clinimetric properties, and especially diagnostic accuracy and responsiveness, to increase utility for clinical practice.

  2. Human Papillomavirus (HPV) Infection in Squamous Cell Carcinomas Arising From the Oropharynx: Detection of HPV DNA and p16 Immunohistochemistry as Diagnostic and Prognostic Indicators—A Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bussu, Francesco, E-mail: francesco.bussu.md@gmail.com; Sali, Michela; Gallus, Roberto

    Purpose: Human papillomavirus (HPV) 16 infection is associated with oropharyngeal carcinogenesis and is likely the cause of the reported increase in disease incidence. We evaluated the prevalence of HPV infection and the reliability of different diagnostic tools using primary tumor samples from a cohort of 50 patients. Methods and Materials: Formalin-fixed paraffin-embedded (FFPE) tumor samples were collected from all 50 consecutive primary oropharyngeal SCC patients who were enrolled in the study; fresh tumor samples were available in 22 cases. NucliSENS EasyQ HPVv1 was used for RNA, and Digene Hybrid Capture-2(HC2) was used for DNA detection. p16 Expression was evaluated bymore » immunohistochemistry in FPPE specimens. Results: Based on the DNA detection assay on FFPE samples, the frequency of high-risk HPV infection was 32%. The agreement rate between HPV RNA and HPV DNA detection in fresh samples was 100%. The agreement rate between p16 immunohistochemistry (IHC) and the detection of HPV DNA in the FFPE samples was fair but not excellent (κ = 0.618). HPV DNA detection was highly significant, as measured by disease-specific survival and determined using a Wilcoxon test (P=.001). p16 IHC also exhibited a prognostic value but with a lower statistical significance (P=.0475). The detection of HPV DNA, but not p16 IHC, was also significantly correlated with locoregional control (P=.0461). Conclusion: Diagnostic methods based on the detection of HPV nucleic acids appear to be more reliable and objective because they do not require reading by a trained histopathologist. Furthermore, the detection of HPV DNA exhibits an improved correlation with survival, and therefore appears definitely more reliable than p16 IHC for routine use in clinical practice.« less

  3. Study of a Vocal Feature Selection Method and Vocal Properties for Discriminating Four Constitution Types

    PubMed Central

    Kim, Keun Ho; Ku, Boncho; Kang, Namsik; Kim, Young-Su; Jang, Jun-Su; Kim, Jong Yeol

    2012-01-01

    The voice has been used to classify the four constitution types, and to recognize a subject's health condition by extracting meaningful physical quantities, in traditional Korean medicine. In this paper, we propose a method of selecting the reliable variables from various voice features, such as frequency derivative features, frequency band ratios, and intensity, from vowels and a sentence. Further, we suggest a process to extract independent variables by eliminating explanatory variables and reducing their correlation and remove outlying data to enable reliable discriminant analysis. Moreover, the suitable division of data for analysis, according to the gender and age of subjects, is discussed. Finally, the vocal features are applied to a discriminant analysis to classify each constitution type. This method of voice classification can be widely used in the u-Healthcare system of personalized medicine and for improving diagnostic accuracy. PMID:22529874

  4. Warfighter Neuroendocrinology: Modeling Stress Response, PTSD, and TBI

    DTIC Science & Technology

    studies are challenged by incongruent diagnostic criteria and confounding treatment protocols. Understanding PTSD is not a simple task as there is no...reliable biological predictor or marker for PTSD and diagnoses are heavily reliant on self-reporting. Current treatments include psychotherapy and...pharmacotherapy: it is not very clear how the two intervention methods inform each other and they are not always very successful. In part, these challenges

  5. Recall and dating of psychiatric symptoms. Test-retest reliability of time-related symptom questions in a standardized psychiatric interview.

    PubMed

    Wittchen, H U; Burke, J D; Semler, G; Pfister, H; Von Cranach, M; Zaudig, M

    1989-05-01

    The advent of more explicit diagnostic criteria and the growing interest in "lifetime" rates of mental disorders has made imperative an accurate determination of time-related diagnostic criteria. We used data from two independent test-retest studies of the Diagnostic Interview Schedule (DIS) and the Composite International Diagnostic Interview (CIDI) to study the reliability of different time-related questions in these fully standardized diagnostic interviews. With two exceptions (anxiety disorders and alcohol-related questions), the test-retest reliability of most time-related questions in both interviews was judged to be satisfactorily high. Furthermore, the validity of time-related questions in the DIS (age at symptom onset, duration and frequency of illness episodes) was examined by comparing them with detailed "consensus" ratings done independently by different clinicians for 207 former psychiatric inpatients. A surprisingly high concordance was found for former psychotic patients except for those still severely disturbed at the follow-up investigation. Some severe restrictions were also found for nonpsychotic disorders with regard to judgment of the age at onset of phobias, panic attacks, and depression. For a more valid assessment of time-related symptom information, the use of specific memory aids is suggested.

  6. The German version of the Posttraumatic Stress Disorder Checklist for DSM-5 (PCL-5): psychometric properties and diagnostic utility.

    PubMed

    Krüger-Gottschalk, Antje; Knaevelsrud, Christine; Rau, Heinrich; Dyer, Anne; Schäfer, Ingo; Schellong, Julia; Ehring, Thomas

    2017-11-28

    The Posttraumatic Stress Disorder (PTSD) Checklist (PCL, now PCL-5) has recently been revised to reflect the new diagnostic criteria of the disorder. A clinical sample of trauma-exposed individuals (N = 352) was assessed with the Clinician Administered PTSD Scale for DSM-5 (CAPS-5) and the PCL-5. Internal consistencies and test-retest reliability were computed. To investigate diagnostic accuracy, we calculated receiver operating curves. Confirmatory factor analyses (CFA) were performed to analyze the structural validity. Results showed high internal consistency (α = .95), high test-retest reliability (r = .91) and a high correlation with the total severity score of the CAPS-5, r = .77. In addition, the recommended cutoff of 33 on the PCL-5 showed high diagnostic accuracy when compared to the diagnosis established by the CAPS-5. CFAs comparing the DSM-5 model with alternative models (the three-factor solution, the dysphoria, anhedonia, externalizing behavior and hybrid model) to account for the structural validity of the PCL-5 remained inconclusive. Overall, the findings show that the German PCL-5 is a reliable instrument with good diagnostic accuracy. However, more research evaluating the underlying factor structure is needed.

  7. Conversion-Integration of MSFC Nonlinear Signal Diagnostic Analysis Algorithms for Realtime Execution of MSFC's MPP Prototype System

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1996-01-01

    NASA's advanced propulsion system Small Scale Magnetic Disturbances/Advanced Technology Development (SSME/ATD) has been undergoing extensive flight certification and developmental testing, which involves large numbers of health monitoring measurements. To enhance engine safety and reliability, detailed analysis and evaluation of the measurement signals are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce the risk of catastrophic system failures and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. During the development of SSME, ASRI participated in the research and development of several advanced non- linear signal diagnostic methods for health monitoring and failure prediction in turbomachinery components. However, due to the intensive computational requirement associated with such advanced analysis tasks, current SSME dynamic data analysis and diagnostic evaluation is performed off-line following flight or ground test with a typical diagnostic turnaround time of one to two days. The objective of MSFC's MPP Prototype System is to eliminate such 'diagnostic lag time' by achieving signal processing and analysis in real-time. Such an on-line diagnostic system can provide sufficient lead time to initiate corrective action and also to enable efficient scheduling of inspection, maintenance and repair activities. The major objective of this project was to convert and implement a number of advanced nonlinear diagnostic DSP algorithms in a format consistent with that required for integration into the Vanderbilt Multigraph Architecture (MGA) Model Based Programming environment. This effort will allow the real-time execution of these algorithms using the MSFC MPP Prototype System. ASRI has completed the software conversion and integration of a sequence of nonlinear signal analysis techniques specified in the SOW for real-time execution on MSFC's MPP Prototype. This report documents and summarizes the results of the contract tasks; provides the complete computer source code; including all FORTRAN/C Utilities; and all other utilities/supporting software libraries that are required for operation.

  8. Ultrasound for Distal Forearm Fracture: A Systematic Review and Diagnostic Meta-Analysis

    PubMed Central

    Douma-den Hamer, Djoke; Blanker, Marco H.; Edens, Mireille A.; Buijteweg, Lonneke N.; Boomsma, Martijn F.; van Helden, Sven H.; Mauritz, Gert-Jan

    2016-01-01

    Study Objective To determine the diagnostic accuracy of ultrasound for detecting distal forearm fractures. Methods A systematic review and diagnostic meta-analysis was performed according to the PRISMA statement. We searched MEDLINE, Web of Science and the Cochrane Library from inception to September 2015. All prospective studies of the diagnostic accuracy of ultrasound versus radiography as the reference standard were included. We excluded studies with a retrospective design and those with evidence of verification bias. We assessed the methodological quality of the included studies with the QUADAS-2 tool. We performed a meta-analysis of studies evaluating ultrasound to calculate the pooled sensitivity and specificity with 95% confidence intervals (CI95%) using a bivariate model with random effects. Subgroup and sensitivity analysis were used to examine the effect of methodological differences and other study characteristics. Results Out of 867 publications we included 16 studies with 1,204 patients and 641 fractures. The pooled test characteristics for ultrasound were: sensitivity 97% (CI95% 93–99%), specificity 95% (CI95% 89–98%), positive likelihood ratio (LR) 20.0 (8.5–47.2) and negative LR 0.03 (0.01–0.08). The corresponding pooled diagnostic odds ratio (DOR) was 667 (142–3,133). Apparent differences were shown for method of viewing, with the 6-view method showing higher specificity, positive LR, and DOR, compared to the 4-view method. Conclusion The present meta-analysis showed that ultrasound has a high accuracy for the diagnosis of distal forearm fractures in children when used by proper viewing method. Based on this, ultrasound should be considered a reliable alternative, which has the advantages of being radiation free. PMID:27196439

  9. Neurobehavioural assessment and diagnosis in disorders of consciousness: a preliminary study of the Sensory Tool to Assess Responsiveness (STAR).

    PubMed

    Stokes, Verity; Gunn, Sarah; Schouwenaars, Katie; Badwan, Derar

    2018-09-01

    The Sensory Tool to Assess Responsiveness (STAR) is an interdisciplinary neurobehavioural diagnostic tool for individuals with prolonged disorders of consciousness. It utilises current diagnostic criteria and is intended to improve upon the high misdiagnosis rate in this population. This study assesses the inter-rater reliability of the STAR and its diagnostic validity in comparison with the Coma Recovery Scale-Revised (CRS-R) and the Wessex Head Injury Matrix (WHIM). Participants were patients with severe acquired brain injury resulting in a disorder of consciousness, who were admitted to the Royal Leamington Spa Rehabilitation Hospital between 1999 and 2009. Patients underwent sensory stimulation sessions during their period of admission, which were recorded on video. Using this footage, patients were re-assessed for this study using the STAR, WHIM and CRS-R criteria. The STAR demonstrated "moderate" inter-rater reliability, "substantial" diagnostic agreement with the CRS-R, and "moderate" agreement with the WHIM. There were no significant differences between diagnoses assigned by the different assessments. The STAR demonstrated a good degree of inter-rater reliability in identification of diagnoses for patients with disorders of consciousness. The diagnostic outcomes of the STAR agreed at a good level with the CRS-R, moderately with the WHIM, and did not significantly differ from either. This demonstrates the reliability and validity of the STAR, showing its appropriateness for clinical use. Future longitudinal studies and research into the STAR's applicability in long-stay rehabilitation are indicated.

  10. Comparison of four PCR methods for efficient detection of Trypanosoma cruzi in routine diagnostics.

    PubMed

    Seiringer, Peter; Pritsch, Michael; Flores-Chavez, María; Marchisio, Edoardo; Helfrich, Kerstin; Mengele, Carolin; Hohnerlein, Stefan; Bretzel, Gisela; Löscher, Thomas; Hoelscher, Michael; Berens-Riha, Nicole

    2017-07-01

    Due to increased migration, Chagas disease has become an international health problem. Reliable diagnosis of chronically infected people is crucial for prevention of non-vectorial transmission as well as treatment. This study compared four distinct PCR methods for detection of Trypanosoma cruzi DNA for the use in well-equipped routine diagnostic laboratories. DNA was extracted of T. cruzi-positive and negative patients' blood samples and cultured T. cruzi, T. rangeli as well as Leishmania spp. One conventional and two real-time PCR methods targeting a repetitive Sat-DNA sequence as well as one conventional PCR method targeting the variable region of the kDNA minicircle were compared for sensitivity, intra- and interassay precision, limit of detection, specificity and cross-reactivity. Considering the performance, costs and ease of use, an algorithm for PCR-diagnosis of patients with a positive serology for T. cruzi antibodies was developed. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  11. The clinical performance evaluation of novel protein chips for eleven biomarkers detection and the diagnostic model study.

    PubMed

    Luo, Yuan; Zhu, Xu; Zhang, Pengjun; Shen, Qian; Wang, Zi; Wen, Xinyu; Wang, Ling; Gao, Jing; Dong, Jin; Yang, Caie; Wu, Tangming; Zhu, Zheng; Tian, Yaping

    2015-01-01

    We aimed to develop and validate two novel protein chips, which are based on microarray chemiluminescence immunoassay and can simultaneously detected 11 biomarkers, and then to evaluate their clinical diagnostic value by comparing with the traditional methods. Protein chips were evaluated for limit of detection, specificity, common interferences, linearity, precision and accuracy. 11 biomarkers were simultaneously detected by traditional methods and protein chips in 3683 samples, which included 1723 cancer patients, 1798 benign diseases patients and 162 healthy controls. After assay validation, protein chips demonstrated high sensitivity, high specificity, good linearity, low imprecision and were free of common interferences. Compared with the traditional methods, protein chips have good correlation in the detection of all the 13 kinds of biomarkers (r≥0.935, P<0.001). For specific cancer detection, there were no statistically significant differences between the traditional method and novel protein chips, except that male protein chip showed significantly better diagnostic value on NSE detection (P=0.004) but significantly worse value on pro-GRP detection (P=0.012), female chip showed significantly better diagnostic value on pro-GRP detection (P=0.005). Furthermore, both male and female multivariate diagnostic models had significantly better diagnostic value than single detection of PGI, PG II, pro-GRP, NSE and CA125 (P<0.05). In addition, male models had significantly better diagnostic value than single CA199 and free-PSA (P<0.05), while female models observed significantly better diagnostic value than single CA724 and β-HCG (P<0.05). For total disease or cancer detection, the AUC of multivariate logistic regression for the male and female disease detection was 0.981 (95% CI: 0.975-0.987) and 0.836 (95% CI: 0.798-0.874), respectively. While, that for total cancer detection was 0.691 (95% CI: 0.666-0.717) and 0.753 (95% CI: 0.731-0.775), respectively. The new designed protein chips are simple, multiplex and reliable clinical assays and the multi-parameter diagnostic models based on them could significantly improve their clinical performance.

  12. The clinical performance evaluation of novel protein chips for eleven biomarkers detection and the diagnostic model study

    PubMed Central

    Luo, Yuan; Zhu, Xu; Zhang, Pengjun; Shen, Qian; Wang, Zi; Wen, Xinyu; Wang, Ling; Gao, Jing; Dong, Jin; Yang, Caie; Wu, Tangming; Zhu, Zheng; Tian, Yaping

    2015-01-01

    We aimed to develop and validate two novel protein chips, which are based on microarray chemiluminescence immunoassay and can simultaneously detected 11 biomarkers, and then to evaluate their clinical diagnostic value by comparing with the traditional methods. Protein chips were evaluated for limit of detection, specificity, common interferences, linearity, precision and accuracy. 11 biomarkers were simultaneously detected by traditional methods and protein chips in 3683 samples, which included 1723 cancer patients, 1798 benign diseases patients and 162 healthy controls. After assay validation, protein chips demonstrated high sensitivity, high specificity, good linearity, low imprecision and were free of common interferences. Compared with the traditional methods, protein chips have good correlation in the detection of all the 13 kinds of biomarkers (r≥0.935, P<0.001). For specific cancer detection, there were no statistically significant differences between the traditional method and novel protein chips, except that male protein chip showed significantly better diagnostic value on NSE detection (P=0.004) but significantly worse value on pro-GRP detection (P=0.012), female chip showed significantly better diagnostic value on pro-GRP detection (P=0.005). Furthermore, both male and female multivariate diagnostic models had significantly better diagnostic value than single detection of PGI, PG II, pro-GRP, NSE and CA125 (P<0.05). In addition, male models had significantly better diagnostic value than single CA199 and free-PSA (P<0.05), while female models observed significantly better diagnostic value than single CA724 and β-HCG (P<0.05). For total disease or cancer detection, the AUC of multivariate logistic regression for the male and female disease detection was 0.981 (95% CI: 0.975-0.987) and 0.836 (95% CI: 0.798-0.874), respectively. While, that for total cancer detection was 0.691 (95% CI: 0.666-0.717) and 0.753 (95% CI: 0.731-0.775), respectively. The new designed protein chips are simple, multiplex and reliable clinical assays and the multi-parameter diagnostic models based on them could significantly improve their clinical performance. PMID:26884957

  13. Lessons learned developing a diagnostic tool for HIV-associated dementia feasible to implement in resource-limited settings: pilot testing in Kenya.

    PubMed

    Kwasa, Judith; Cettomai, Deanna; Lwanya, Edwin; Osiemo, Dennis; Oyaro, Patrick; Birbeck, Gretchen L; Price, Richard W; Bukusi, Elizabeth A; Cohen, Craig R; Meyer, Ana-Claire L

    2012-01-01

    To conduct a preliminary evaluation of the utility and reliability of a diagnostic tool for HIV-associated dementia (HAD) for use by primary health care workers (HCW) which would be feasible to implement in resource-limited settings. In resource-limited settings, HAD is an indication for anti-retroviral therapy regardless of CD4 T-cell count. Anti-retroviral therapy, the treatment for HAD, is now increasingly available in resource-limited settings. Nonetheless, HAD remains under-diagnosed likely because of limited clinical expertise and availability of diagnostic tests. Thus, a simple diagnostic tool which is practical to implement in resource-limited settings is an urgent need. A convenience sample of 30 HIV-infected outpatients was enrolled in Western Kenya. We assessed the sensitivity and specificity of a diagnostic tool for HAD as administered by a primary HCW. This was compared to an expert clinical assessment which included examination by a physician, neuropsychological testing, and in selected cases, brain imaging. Agreement between HCW and an expert examiner on certain tool components was measured using Kappa statistic. The sample was 57% male, mean age was 38.6 years, mean CD4 T-cell count was 323 cells/µL, and 54% had less than a secondary school education. Six (20%) of the subjects were diagnosed with HAD by expert clinical assessment. The diagnostic tool was 63% sensitive and 67% specific for HAD. Agreement between HCW and expert examiners was poor for many individual items of the diagnostic tool (K = .03-.65). This diagnostic tool had moderate sensitivity and specificity for HAD. However, reliability was poor, suggesting that substantial training and formal evaluations of training adequacy will be critical to enable HCW to reliably administer a brief diagnostic tool for HAD.

  14. Characterization of optically stimulated luminescence dosemeters to measure organ doses in diagnostic radiology

    PubMed Central

    Endo, A; Katoh, T; Kobayashi, I; Joshi, R; Sur, J; Okano, T

    2012-01-01

    Objective The aim of this study was to assess the characteristics of an optically stimulated luminescence dosemeter (OSLD) for use in diagnostic radiology and to apply the OSLD in measuring the organ doses by panoramic radiography. Methods The dose linearity, energy dependency and angular dependency of aluminium oxide-based OSLDs were examined using an X-ray generator to simulate various exposure settings in diagnostic radiology. The organ doses were then measured by inserting the dosemeters into an anthropomorphic phantom while using three panoramic machines. Results The dosemeters demonstrated consistent dose linearity (coefficient of variation<1.5%) and no significant energy dependency (coefficient of variation<1.5%) under the applied exposure conditions. They also exhibited negligible angular dependency (≤10%). The organ doses of the X-ray as a result of panoramic imaging by three machines were calculated using the dosemeters. Conclusion OSLDs can be utilized to measure the organ doses in diagnostic radiology. The availability of these dosemeters in strip form proves to be reliably advantageous. PMID:22116136

  15. Prime Diagnosticity in Short-Term Repetition Priming: Is Primed Evidence Discounted, Even when It Reliably Indicates the Correct Answer?

    ERIC Educational Resources Information Center

    Weidemann, Christoph T.; Huber, David E.; Shiffrin, Richard M.

    2008-01-01

    The authors conducted 4 repetition priming experiments that manipulated prime duration and prime diagnosticity in a visual forced-choice perceptual identification task. The strength and direction of prime diagnosticity produced marked effects on identification accuracy, but those effects were resistant to subsequent changes of diagnosticity.…

  16. Machine learning classification with confidence: application of transductive conformal predictors to MRI-based diagnostic and prognostic markers in depression.

    PubMed

    Nouretdinov, Ilia; Costafreda, Sergi G; Gammerman, Alexander; Chervonenkis, Alexey; Vovk, Vladimir; Vapnik, Vladimir; Fu, Cynthia H Y

    2011-05-15

    There is rapidly accumulating evidence that the application of machine learning classification to neuroimaging measurements may be valuable for the development of diagnostic and prognostic prediction tools in psychiatry. However, current methods do not produce a measure of the reliability of the predictions. Knowing the risk of the error associated with a given prediction is essential for the development of neuroimaging-based clinical tools. We propose a general probabilistic classification method to produce measures of confidence for magnetic resonance imaging (MRI) data. We describe the application of transductive conformal predictor (TCP) to MRI images. TCP generates the most likely prediction and a valid measure of confidence, as well as the set of all possible predictions for a given confidence level. We present the theoretical motivation for TCP, and we have applied TCP to structural and functional MRI data in patients and healthy controls to investigate diagnostic and prognostic prediction in depression. We verify that TCP predictions are as accurate as those obtained with more standard machine learning methods, such as support vector machine, while providing the additional benefit of a valid measure of confidence for each prediction. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. Towards novel compact laser sources for non-invasive diagnostics and treatment

    NASA Astrophysics Data System (ADS)

    Rafailov, Edik U.; Litvinova, Karina S.; Sokolovski, Sergei G.

    2015-08-01

    An important field of application of lasers is biomedical optics. Here, they offer great utility for diagnosis, therapy and surgery. For the development of novel methods of laser-based biomedical diagnostics careful study of light propagation in biological tissues is necessary to enhance our understanding of the optical measurements undertaken, increase research and development capacity and the diagnostic reliability of optical technologies. Ultimately, fulfilling these requirements will increase uptake in clinical applications of laser based diagnostics and therapeutics. To address these challenges informative biomarkers relevant to the biological and physiological function or disease state of the organism must be selected. These indicators are the results of the analysis of tissues and cells, such as blood. For non-invasive diagnostics peripheral blood, cells and tissue can potentially provide comprehensive information on the condition of the human organism. A detailed study of the light scattering and absorption characteristics can quickly detect physiological and morphological changes in the cells due to thermal, chemical, antibiotic treatments, etc [1-5]. The selection of a laser source to study the structure of biological particles also benefits from the fact that gross pathological changes are not induced and diagnostics make effective use of the monochromatic directional coherence properties of laser radiation.

  18. Reliability of laser Doppler flowmetry curve reading for measurement of toe and ankle pressures: intra- and inter-observer variation.

    PubMed

    Høyer, C; Paludan, J P D; Pavar, S; Biurrun Manresa, J A; Petersen, L J

    2014-03-01

    To assess the intra- and inter-observer variation in laser Doppler flowmetry curve reading for measurement of toe and ankle pressures. A prospective single blinded diagnostic accuracy study was conducted on 200 patients with known or suspected peripheral arterial disease (PAD), with a total of 760 curve sets produced. The first curve reading for this study was performed by laboratory technologists blinded to clinical clues and previous readings at least 3 months after the primary data sampling. The pressure curves were later reassessed following another period of at least 3 months. Observer agreement in diagnostic classification according to TASC-II criteria was quantified using Cohen's kappa. Reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis. The overall agreement in diagnostic classification (PAD/not PAD) was 173/200 (87%) for intra-observer (κ = .858) and 175/200 (88%) for inter-observer data (κ = .787). Reliability analysis confirmed excellent correlation for both intra- and inter-observer data (ICC all ≥.931). The coefficients of variance ranged from 2.27% to 6.44% for intra-observer and 2.39% to 8.42% for inter-observer data. Subgroup analysis showed lower observer-variation for reading of toe pressures in patients with diabetes and/or chronic kidney disease than patients not diagnosed with these conditions. Bland-Altman plots showed higher variation in toe pressure readings than ankle pressure readings. This study shows substantial intra- and inter-observer agreement in diagnostic classification and reading of absolute pressures when using laboratory technologists as observers. The study emphasises that observer variation for curve reading is an important factor concerning the overall reproducibility of the method. Our data suggest diabetes and chronic kidney disease have an influence on toe pressure reproducibility. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Rapid and simple detection of foot-and-mouth disease virus: Evaluation of a cartridge-based molecular detection system for use in basic laboratories.

    PubMed

    Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L

    2018-04-01

    Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  20. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    PubMed Central

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra-articular disorder (sensitivity of 0.80 and specificity of 0.97). Diagnostic criteria for other common intra-articular disorders lack adequate validity for clinical diagnoses but can be used for screening purposes. Inter-examiner reliability for the clinical assessment associated with the validated DC/TMD criteria for pain-related TMD is excellent (kappa ≥ 0.85). Finally, a comprehensive classification system that includes both the common and less common TMD is also presented. The Axis II protocol retains selected original RDC/TMD screening instruments augmented with new instruments to assess jaw function as well as behavioral and additional psychosocial factors. The Axis II protocol is divided into screening and comprehensive self-report instrument sets. The screening instruments’ 41 questions assess pain intensity, pain-related disability, psychological distress, jaw functional limitations, and parafunctional behaviors, and a pain drawing is used to assess locations of pain. The comprehensive instruments, composed of 81 questions, assess in further detail jaw functional limitations and psychological distress as well as additional constructs of anxiety and presence of comorbid pain conditions. Conclusion The recommended evidence-based new DC/TMD protocol is appropriate for use in both clinical and research settings. More comprehensive instruments augment short and simple screening instruments for Axis I and Axis II. These validated instruments allow for identification of patients with a range of simple to complex TMD presentations. PMID:24482784

  1. The role of liquid-based cytology and ancillary techniques in pleural and pericardic effusions: an institutional experience.

    PubMed

    Rossi, Esther Diana; Bizzarro, Tommaso; Schmitt, Fernando; Longatto-Filho, Adhemar

    2015-04-01

    Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility. © 2015 American Cancer Society.

  2. [Definition of the Diagnosis Osteomyelitis-Osteomyelitis Diagnosis Score (ODS)].

    PubMed

    Schmidt, H G K; Tiemann, A H; Braunschweig, R; Diefenbeck, M; Bühler, M; Abitzsch, D; Haustedt, N; Walter, G; Schoop, R; Heppert, V; Hofmann, G O; Glombitza, M; Grimme, C; Gerlach, U-J; Flesch, I

    2011-08-01

    The disease "osteomyelitis" is characterised by different symptoms and parameters. Decisive roles in the development of the disease are played by the causative bacteria, the route of infection and the individual defense mechanisms of the host. The diagnosis is based on different symptoms and findings from the clinical history, clinical symptoms, laboratory results, diagnostic imaging, microbiological and histopathological analyses. While different osteomyelitis classifications have been published, there is to the best of our knowledge no score that gives information how sure the diagnosis "osteomyelitis" is in general. For any scientific study of a disease a valid definition is essential. We have developed a special osteomyelitis diagnosis score for the reliable classification of clinical, laboratory and technical findings. The score is based on five diagnostic procedures: 1) clinical history and risk factors, 2) clinical examination and laboratory results, 3) diagnostic imaging (ultrasound, radiology, CT, MRI, nuclear medicine and hybrid methods), 4) microbiology, and 5) histopathology. Each diagnostic procedure is related to many individual findings, which are weighted by a score system, in order to achieve a relevant value for each assessment. If the sum of the five diagnostic criteria is 18 or more points, the diagnosis of osteomyelitis can be viewed as "safe" (diagnosis class A). Between 8-17 points the diagnosis is "probable" (diagnosis class B). Less than 8 points means that the diagnosis is "possible, but unlikely" (class C diagnosis). Since each parameter can score six points at a maximum, a reliable diagnosis can only be achieved if at least 3 parameters are scored with 6 points. The osteomyelitis diagnosis score should help to avoid the false description of a clinical presentation as "osteomyelitis". A safe diagnosis is essential for the aetiology, treatment and outcome studies of osteomyelitis. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Diagnostic methods of TSH in thyroid screening tests.

    PubMed

    Matyjaszek-Matuszek, Beata; Pyzik, Aleksandra; Nowakowski, Andrzej; Jarosz, Mirosław J

    2013-01-01

    Reliable and quick thyreologic diagnostics, as well as verification of the effectiveness of the therapy undertaken, is of great importance for the state of health of society. The measurement of plasma TSH is the commonly accepted and most sensitive screening test for primary thyroid disorders, which are the most frequent diseases related to the endocrine glands. At present, the available methods for the determination of TSH are characterized by high sensitivity ≤0.01 µIU/ml and lack of cross-reactivity. However, many drugs and substances, as well as pathological conditions, may affect the TSH level. evaluation of contemporary laboratory methods for the determination of TSH and the principles of interpretation of screening tests. In many countries, the TSH test is the only test performed in the diagnostics of thyroid function; nevertheless, it seems that for genuine and objective assessment of thyroid status the TSH level, together with FT4 level, should be absolutely determined, which allows the differentiation and assessment of the intensity of thyroid function disorders and foresee its consequences. The interpretation of TSH results in screening tests is different in such population groups as: children aged under 14, pregnant women, the elderly, and patients with non-thyroidal illnesses. From among currently used laboratory methods for determination of TSH levels, third generation non-isotopic methods are most frequently recommended, especially the method of immunochemiluminescence.

  4. Developing a new diagnostic algorithm for human papilloma virus associated oropharyngeal carcinoma: an investigation of HPV DNA assays.

    PubMed

    Cohen, Natasha; Gupta, Michael; Doerwald-Munoz, Lilian; Jang, Dan; Young, James Edward Massey; Archibald, Stuart; Jackson, Bernard; Lee, Jenny; Chernesky, Max

    2017-02-13

    Human papilloma virus (HPV) has been implicated in the development of a large proportion of oropharyngeal squamous cell carcinoma (OPSCC). Current techniques used to diagnose HPV etiology require histopathologic analysis. We aim to investigate the diagnostic accuracy of a new application non-histopathologic diagnostic tests to help assist diagnosis of HPV-related oropharyngeal tumors. Patients with OPSCC with nodal metastasis were consecutively recruited from a multidisciplinary cancer clinic. Appropriate samples were collected and analyzed. The various tests examined included COBAS® 4800, Cervista® HR and Genotyping. These tests were compared to p16 staining, which was used as the diagnostic standard. StataIC 14.2 was used to perform analysis, including sensitivity, specificity and receiver operator characteristic [ROC] curves. The COBAS® FNA (area under ROC 0.863) and saliva (area under ROC 0.847) samples performed well in diagnosing HPV positive and negative tumors. Samples tested with Cervista® did not corroborate p16 status reliably. We were able to increase the diagnostic yield of the COBAS® FNA samples by applying the results of the saliva test to negative FNA samples which correctly identified 11 additional p16 positive tumors (area under ROC 0.915). Surrogate testing for HPV using alternate methods is feasible and closely predicts the results of standard diagnostic methods. In the future, these could minimize invasive procedures for diagnosing HPV-related oropharyngeal cancer, but also help to diagnose and treat patients with unknown primaries.

  5. Rapid and sensitive multiplex single-tube nested PCR for the identification of five human Plasmodium species.

    PubMed

    Saito, Takahiro; Kikuchi, Aoi; Kaneko, Akira; Isozumi, Rie; Teramoto, Isao; Kimura, Masatsugu; Hirasawa, Noriyasu; Hiratsuka, Masahiro

    2018-06-01

    Malaria is caused by five species of Plasmodium in humans. Microscopy is currently used for pathogen detection, requiring considerable training and technical expertise as the parasites are often difficult to differentiate morphologically. Rapid diagnostic tests are as reliable as microscopy and offer faster diagnoses but possess lower detection limits and are incapable of distinguishing among the parasitic species. To improve global health efforts towards malaria control, a rapid, sensitive, species-specific, and economically viable diagnostic method is needed. In this study, we designed a malaria diagnostic method involving a multiplex single-tube nested PCR targeting Plasmodium mitochondrial cytochrome c oxidase III and single-stranded tag hybridization chromatographic printed-array strip. The detection sensitivity was found to be at least 40 times higher than that of agarose gel electrophoresis with ethidium bromide. This system also enables the identification of both single- and mixed-species malaria infections. The assay was validated with 152 Kenyan samples; using nested PCR as the standard, the assay's sensitivity and specificity were 88.7% and 100.0%, respectively. The turnaround time required, from PCR preparation to signal detection, is 90min. Our method should improve the diagnostic speed, treatment efficacy, and control of malaria, in addition to facilitating surveillance within global malaria eradication programs. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Theoretical investigation of gas-surface interactions

    NASA Technical Reports Server (NTRS)

    Lee, Timothy J.

    1989-01-01

    Four reprints are presented from four projects which are to be published in a refereed journal. Two are of interest to us and are presented herein. One is a description of a very detailed theoretical study of four anionic hydrogen bonded complexes. The other is a detailed study of the first generally reliable diagnostic for determining the quality of results that may be expected from single reference based electron correlation methods.

  7. A Comparison of Vibration and Oil Debris Gear Damage Detection Methods Applied to Pitting Damage

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.

    2000-01-01

    Helicopter Health Usage Monitoring Systems (HUMS) must provide reliable, real-time performance monitoring of helicopter operating parameters to prevent damage of flight critical components. Helicopter transmission diagnostics are an important part of a helicopter HUMS. In order to improve the reliability of transmission diagnostics, many researchers propose combining two technologies, vibration and oil monitoring, using data fusion and intelligent systems. Some benefits of combining multiple sensors to make decisions include improved detection capabilities and increased probability the event is detected. However, if the sensors are inaccurate, or the features extracted from the sensors are poor predictors of transmission health, integration of these sensors will decrease the accuracy of damage prediction. For this reason, one must verify the individual integrity of vibration and oil analysis methods prior to integrating the two technologies. This research focuses on comparing the capability of two vibration algorithms, FM4 and NA4, and a commercially available on-line oil debris monitor to detect pitting damage on spur gears in the NASA Glenn Research Center Spur Gear Fatigue Test Rig. Results from this research indicate that the rate of change of debris mass measured by the oil debris monitor is comparable to the vibration algorithms in detecting gear pitting damage.

  8. Evaluation of Contrast Extravasation as a Diagnostic Criterion in the Evaluation of Arthroscopically Proven HAGL/pHAGL Lesions

    PubMed Central

    Maldjian, Catherine; Khanna, Vineet; Bradley, James; Adam, Richard

    2014-01-01

    Purpose. The validity of preoperative MRI in diagnosing HAGL lesions is debated. Various investigations have produced mixed results with regard to the utility of MRI. The purpose of this investigation is to apply a novel method of diagnosing HAGL/pHAGL lesions by looking at contrast extravasation and to evaluate the reliability of such extravasation of contrast into an extra-articular space as a sign of HAGL/pHAGL lesion. Methods. We utilized specific criteria to define contrast extravasation. We evaluated these criteria in 12 patients with arthroscopically proven HAGL/pHAGL lesion. We also evaluated these criteria in a control group. Results. Contrast extravasation occurred in over 83% of arthroscopically positive cases. Contrast extravasation as a diagnostic criterion in the evaluation of HAGL/pHAGL lesions demonstrated a high interobserver degree of agreement. Conclusions. In conclusion, extra-articular contrast extravasation may serve as a valid and reliable sign of HAGL and pHAGL lesions, provided stringent criteria are maintained to assure that the contrast lies in an extra-articular location. In cases where extravasation is not present, the “J” sign, though nonspecific, may be the only evidence of subtle HAGL and pHAGL lesions. Level of Evidence. Level IV, Retrospective Case-Control series. PMID:25530880

  9. A System for Heart Sounds Classification

    PubMed Central

    Redlarski, Grzegorz; Gradolewski, Dawid; Palkowski, Aleksander

    2014-01-01

    The future of quick and efficient disease diagnosis lays in the development of reliable non-invasive methods. As for the cardiac diseases – one of the major causes of death around the globe – a concept of an electronic stethoscope equipped with an automatic heart tone identification system appears to be the best solution. Thanks to the advancement in technology, the quality of phonocardiography signals is no longer an issue. However, appropriate algorithms for auto-diagnosis systems of heart diseases that could be capable of distinguishing most of known pathological states have not been yet developed. The main issue is non-stationary character of phonocardiography signals as well as a wide range of distinguishable pathological heart sounds. In this paper a new heart sound classification technique, which might find use in medical diagnostic systems, is presented. It is shown that by combining Linear Predictive Coding coefficients, used for future extraction, with a classifier built upon combining Support Vector Machine and Modified Cuckoo Search algorithm, an improvement in performance of the diagnostic system, in terms of accuracy, complexity and range of distinguishable heart sounds, can be made. The developed system achieved accuracy above 93% for all considered cases including simultaneous identification of twelve different heart sound classes. The respective system is compared with four different major classification methods, proving its reliability. PMID:25393113

  10. Diagnostic classification past, present, and future: implications for pharmacotherapy.

    PubMed

    Howland, Robert H

    2013-04-01

    Making a diagnosis is a key step in understanding the natural course of a disorder, selecting an appropriate treatment for the disorder, and predicting its response to treatment. Diagnostic proposals can be evaluated in two ways: reliability and validity. The reliability and validity of diagnoses are not one and the same, although establishing reliability is usually a necessary step before being able to evaluate and determine validity. There is little evidence that most psychiatric diagnoses are valid, but the reliability of diagnoses using classification systems developed since 1970 have greatly improved and are important for clinical practice and research. Past and current diagnostic systems have not optimally assisted the search for disorder-specific pathophysiological mechanisms, and they do not provide the specificity that clinicians would like when selecting medication. The Research Domain Criteria project is intended to shift research away from categorical diagnoses to focus on dysregulated neurobiological systems, and this approach ultimately may be more useful for understanding the pathophysiology of mental disorders and improving the development and use of treatment interventions. Copyright 2013, SLACK Incorporated.

  11. Reliability and precision of stress sonography of the ulnar collateral ligament.

    PubMed

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  12. Critically re-evaluating a common technique: Accuracy, reliability, and confirmation bias of EMG.

    PubMed

    Narayanaswami, Pushpa; Geisbush, Thomas; Jones, Lyell; Weiss, Michael; Mozaffar, Tahseen; Gronseth, Gary; Rutkove, Seward B

    2016-01-19

    (1) To assess the diagnostic accuracy of EMG in radiculopathy. (2) To evaluate the intrarater reliability and interrater reliability of EMG in radiculopathy. (3) To assess the presence of confirmation bias in EMG. Three experienced academic electromyographers interpreted 3 compact discs with 20 EMG videos (10 normal, 10 radiculopathy) in a blinded, standardized fashion without information regarding the nature of the study. The EMGs were interpreted 3 times (discs A, B, C) 1 month apart. Clinical information was provided only with disc C. Intrarater reliability was calculated by comparing interpretations in discs A and B, interrater reliability by comparing interpretation between reviewers. Confirmation bias was estimated by the difference in correct interpretations when clinical information was provided. Sensitivity was similar to previous reports (77%, confidence interval [CI] 63%-90%); specificity was 71%, CI 56%-85%. Intrarater reliability was good (κ 0.61, 95% CI 0.41-0.81); interrater reliability was lower (κ 0.53, CI 0.35-0.71). There was no substantial confirmation bias when clinical information was provided (absolute difference in correct responses 2.2%, CI -13.3% to 17.7%); the study lacked precision to exclude moderate confirmation bias. This study supports that (1) serial EMG studies should be performed by the same electromyographer since intrarater reliability is better than interrater reliability; (2) knowledge of clinical information does not bias EMG interpretation substantially; (3) EMG has moderate diagnostic accuracy for radiculopathy with modest specificity and electromyographers should exercise caution interpreting mild abnormalities. This study provides Class III evidence that EMG has moderate diagnostic accuracy and specificity for radiculopathy. © 2015 American Academy of Neurology.

  13. Feasibility and acceptability of the DSM-5 Field Trial procedures in the Johns Hopkins Community Psychiatry Programs†

    PubMed Central

    Clarke, Diana E.; Wilcox, Holly C.; Miller, Leslie; Cullen, Bernadette; Gerring, Joan; Greiner, Lisa H.; Newcomer, Alison; Mckitty, Mellisha V.; Regier, Darrel A.; Narrow, William E.

    2014-01-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) contains criteria for psychiatric diagnoses that reflect advances in the science and conceptualization of mental disorders and address the needs of clinicians. DSM-5 also recommends research on dimensional measures of cross-cutting symptoms and diagnostic severity, which are expected to better capture patients’ experiences with mental disorders. Prior to its May 2013 release, the American Psychiatric Association (APA) conducted field trials to examine the feasibility, clinical utility, reliability, and where possible, the validity of proposed DSM-5 diagnostic criteria and dimensional measures. The methods and measures proposed for the DSM-5 field trials were pilot tested in adult and child/adolescent clinical samples, with the goal to identify and correct design and procedural problems with the proposed methods before resources were expended for the larger DSM-5 Field Trials. Results allowed for the refinement of the protocols, procedures, and measures, which facilitated recruitment, implementation, and completion of the DSM-5 Field Trials. These results highlight the benefits of pilot studies in planning large multisite studies. PMID:24615761

  14. GIS diagnostics: thermal imaging systems used for poor contact detection

    NASA Astrophysics Data System (ADS)

    Avital, Doron; Brandenbursky, V.; Farber, A.

    2004-04-01

    The reliability of GIS is very high but any failure that occurs can cause extensive damage result and the repair times are considerably long. The consequential losses to system security and economically can be high, especially if the nominal GIS voltage is 420 kV and above. In view of these circumstances, increasing attention is being given to diagnostic techniques for in-service maintenance undertaken to improve the reliability and availability of GIS. Recently considerable progress has been made in diagnostic techniques and they are now used successfully during the service life of the equipment. These diagnostic techniques in general focus on the GIS insulation system and are based on partial discharge (PD) measurements in GIS. There are three main methods for in-service PD detection in GIS: - the chemical method that rely on the detection of cracked gas caused by PD, the acoustic method designed to detect the acoustic emission excited by PD, and, the electrical method which is based on detection of electrical resonance at ultra high frequencies (UHF) up to 1.5 GHz caused by PD excitation in GIS chambers (UHF method). These three dielectric diagnostic methods cannot be used for the detection of poor current carrying contacts in GIS. This problem does not always produce partial discharges and at early stages it does not cause gas cracking. An interesting solution to use two techniques - the current unbalance alarm scheme and partial discharge monitoring was advised by A. Salinas from South California Edison Co. Unfortunately this way is complicated and very expensive. The investigations performed in Japan on standing alone SF6 breaker showed that joule heating of the contact accompanied by released power of 1600 Watt produce temperature difference on the enclosure up to 7 degrees centigrade that could be detected by infra-red Thermal Imaging System. According to CIGRE Joint Working Group 33/23.12 Report, 11% of all GIS failures are due to poor current carrying contacts in GIS. The Israel Electric Company (IEC) in seeking a solution to this problem have undertaken experimental work to examine the possibility of in-service diagnostic of poor contact problem in GIS via direct local heating detection, using a Thermal Imaging System. The experiments were carried out on the part of the GIS with nominal SF6 pressure. The following aspects of the problem were examined: - the range of power released in the defective contact that could give the practical temperature rise on the surface of enclosure; - temperature distribution on the surface of enclosure; - the influence of spacer type (with holes or without) on the heat transfer process; - the influence of the length of SF6 tubes and there position (horizontal or vertical); - the temperature difference between upper and lower parts of the tubes in horizontal position; - practical use of the Thermal Imaging System for detecting poor contact problem in GIS.

  15. The Reliability and Criterion Validity of the Diagnostic Infant and Preschool Assessment: A New Diagnostic Instrument for Young Children

    ERIC Educational Resources Information Center

    Scheeringa, Michael S.; Haslett, Nancy

    2010-01-01

    The need to assess Diagnostic and Statistical Manual, Fourth Edition (DSM-IV) disorders in children younger than 7 years of age has intensified as clinical efforts to diagnose and treat this population have increased, and clinical research on psychopathology has advanced. A new diagnostic instrument for young children was created, the Diagnostic…

  16. [Human coronavirus infections: importance and diagnosis].

    PubMed

    Vabret, A; Brouard, J; Petitjean, J; Eugene-Ruellan, G; Freymuth, F

    1998-11-14

    POORLY-KNOWN VIRUS: Coronaviruses, so named because of their sun-ray-like aspect, were discovered in the sixties. The biology of these RNA viruses is complex and poorly understood. KNOWN PATHOGENS: Coronaviruses are known pathogens in veterinary medicine, causing disease states in several domestic species. In human medicine, they can cause benign respiratory infections, but few laboratories include coronaviruses in their routine diagnostic tests. SUSPECTED PATHOGENS: There is some data in the literature suggesting coronaviruses might be implicated in more severe diseases including multiple sclerosis, necrotizing enterocolitis, and lower respiratory tract infections, particularly in infants. IMPROVING DIAGNOSTIC METHODS: Due to the lack of reliable and sensitive diagnostic techniques, it is impossible to date to correctly assess the medical impact of these ubiquitous and endemic viruses. Molecular biology techniques enabling detection of human coronavirus infections should be applied to verifying the suspected implication of these viruses in diverse disease states.

  17. Noninvasive Brain Stimulation in Pediatric ADHD: A Review

    PubMed Central

    Rubio, Belen; Boes, Aaron D.; Laganiere, Simon; Rotenberg, Alexander; Jeurissen, Danique; Pascual-Leone, Alvaro

    2015-01-01

    Attention-deficit hyperactivity disorder (ADHD) is one of the most prevalent neurodevelopmental disorders in the pediatric population. The clinical management of ADHD is currently limited by a lack of reliable diagnostic biomarkers and inadequate therapy for a minority of patients that do not respond to standard pharmacotherapy. There is optimism that noninvasive brain stimulation may help to address these limitations. Transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS) are two methods of noninvasive brain stimulation that modulate cortical excitability and brain network activity. TMS can be used diagnostically to probe cortical neurophysiology, while daily use of repetitive TMS or tDCS can induce long-lasting and potentially therapeutic changes in targeted networks. In this review we highlight research showing the potential diagnostic and therapeutic applications of TMS and tDCS in pediatric ADHD. We also discuss the safety and ethics of using these tools in the pediatric population. PMID:26661481

  18. Autism detection in early childhood (ADEC): reliability and validity data for a Level 2 screening tool for autistic disorder.

    PubMed

    Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna

    2014-03-01

    The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA

  19. Thermometric diagnosis of peripheral nerve injuries. Assessment of the diagnostic accuracy of a new practical technique.

    PubMed

    Ya'ish, F M M; Cooper, J P; Craigen, M A C

    2007-07-01

    The diagnosis of nerve injury using thermotropic liquid crystal temperature strips was compared blindly and prospectively against operative findings in 36 patients requiring surgical exploration for unilateral upper limb lacerations with suspected nerve injury. Thermotropic liquid crystal strips were applied to affected and non-affected segments in both hands in all subjects. A pilot study showed that a simple unilateral laceration without nerve injury results in a cutaneous temperature difference between limbs, but not within each limb. Thus, for detection of a nerve injury, comparison was made against the unaffected nerve distribution in the same hand. Receiver operating characteristic curve analysis showed that an absolute temperature difference > or = 1.0 degrees C was diagnostic of a nerve injury (area under the curve = 0.985, sensitivity = 100%, specificity = 93.8%). Thermotropic liquid crystal strip assessment is a new, reliable and objective method for the diagnosis of traumatic peripheral nerve injuries. If implemented in the acute setting, it could improve the reliability of clinical assessment and reduce the number of negative surgical explorations.

  20. Circulating microRNA Biomarkers as Liquid Biopsy for Cancer Patients: Pros and Cons of Current Assays

    PubMed Central

    Ono, Shigeshi; Lam, Stella; Nagahara, Makoto; Hoon, Dave S. B.

    2015-01-01

    An increasing number of studies have focused on circulating microRNAs (cmiRNA) in cancer patients’ blood for their potential as minimally-invasive biomarkers. Studies have reported the utility of assessing specific miRNAs in blood as diagnostic/prognostic biomarkers; however, the methodologies are not validated or standardized across laboratories. Unfortunately, there is often minimum limited overlap in techniques between results reported even in similar type studies on the same cancer. This hampers interpretation and reliability of cmiRNA as potential cancer biomarkers. Blood collection and processing, cmiRNA extractions, quality and quantity control of assays, defined patient population assessment, reproducibility, and reference standards all affect the cmiRNA assay results. To date, there is no reported definitive method to assess cmiRNAs. Therefore, appropriate and reliable methodologies are highly necessary in order for cmiRNAs to be used in regulated clinical diagnostic laboratories. In this review, we summarize the developments made over the past decade towards cmiRNA detection and discuss the pros and cons of the assays. PMID:26512704

  1. Design of an Fiber-Coupled Laser Heterodyne Interferometer for the FLARE

    NASA Astrophysics Data System (ADS)

    Frank, Samuel; Yoo, Jongsoo; Ji, Hantao; Jara-Almonte, Jon

    2016-10-01

    The FLARE (Facility for Laboratory Reconnection Experiments), which is currently under construction at PPPL, requires a complete set of laboratory plasma diagnostics. The Langmuir probes that will be used in the device to gather local density data require a reliable interferometer system to serve as baseline for density measurement calibration. A fully fiber-coupled infrared laser heterodyne interferometer has been designed in order to serve as the primary line-integrated electron density diagnostic. Thanks to advances in the communications industry many fiber optic devices and phase detection methods have advanced significantly becoming increasingly reliable and inexpensive. Fully fiber coupling a plasma interferometer greatly simplifies alignment procedures needed since the only free space laser path needing alignment is through the plasma itself. Fiber-coupling also provides significant resistance to vibrational noise, a common problem in plasma interferometry systems. This device also uses a greatly simplified phase detection scheme in which chips, originally developed for the communications industry, capable of directly detecting the phase shift of a signal with high time resolution. The design and initial performance of the system will be discussed.

  2. Detection of single bacteria - causative agents of meningitis using raman microscopy

    NASA Astrophysics Data System (ADS)

    Baikova, T. V.; Minaeva, S. A.; Sundukov, A. V.; Svistunova, T. S.; Bagratashvili, V. N.; Alushin, M. V.; Gonchukov, S. A.

    2015-03-01

    Early diagnostics of meningitis is a very topical problem as it is a fulminant disease with a high level of mortality. The progress of this disease is, as a rule, accompanied by the appearance of bacteria in the cerebrospinal fluid (CSF) composition. The examination of the CSF is well known to be the only reliable approach to the identification of meningitis. However, the traditional biochemical analyses are time consuming and not always reliable, simple, and inexpensive, whereas the optical methods are poorly developed. This work is devoted to the study of Raman spectra of several bacterial cultures which are mainly present during meningitis. Raman microscopy is a prompt and noninvasive technique capable of providing reliable information about molecular-level alterations of biological objects at their minimal quantity and size. It was shown that there are characteristic lines in Raman spectra which can be the reliable markers for determination of bacterial form of meningitis at a level of a single bacterium.

  3. The Spanish Diagnostic Interview Schedule. Reliability and comparison with clinical diagnoses.

    PubMed

    Burnam, M A; Karno, M; Hough, R L; Escobar, J I; Forsythe, A B

    1983-11-01

    The National Institute of Mental Health Diagnostic Interview Schedule (DIS) was translated into Spanish. The reliability of the Spanish instrument, its equivalence to the English version, and its agreement with clinical diagnoses were examined in a study of 90 bilingual (English-and Spanish-speaking) and 61 monolingual (Spanish-speaking only) patients from a community mental health center. The study design involved two independent DIS administrations and one independent clinical evaluation of each subject.

  4. Application of Short Screening Tools for Post-Traumatic Stress Disorder in the Korean Elderly Population

    PubMed Central

    Jang, Yu Jin; Chung, Hae Gyung; Choi, Jin Hee; Kim, Tae Yong; So, Hyung Seok

    2016-01-01

    Objective Post-traumatic stress disorder (PTSD) is often missed or incorrectly diagnosed in primary care settings. Although brief screening instruments may be useful in detecting PTSD, an adequate validation study has not been conducted with older adults. This study aimed to evaluate the reliability and validity of the Korean version of the primary care PTSD screen (PC-PTSD) and single-item PTSD screener (SIPS) in elderly veterans. Methods The PC-PTSD and SIPS assessments were translated into Korean, with a back-translation to the original language to verify accuracy. Vietnamese war veterans [separated into a PTSD group (n=41) and a non-PTSD group (n=99)] participated in several psychometric assessments, including the Korean versions of the PC-PTSD (PC-PTSD-K), SIPS (SIPS-K), a structured clinical interview from the Diagnostic and Statistical Manual of Mental Disorders-IV(SCID), and PTSD checklist(PCL). Results The PC-PTSD-K showed high internal consistency (Cronbach α=0.76), and the test-retest reliability of the PC-PTSD-K and SIPS-K were also high (r=0.97 and r=0.91, respectively). A total score of 3 from the PC-PTSD-K yielded the highest diagnostic efficiency, with sensitivity and specificity values of 0.90 and 0.86, respectively. The 'bothered a lot' response level from the SIPS-K showed the highest diagnostic efficiency, with sensitivity and specificity values of 0.85 and 0.89, respectively. Conclusion Our findings suggest that both PC-PTSD-K and SIPS-K have good psychometric properties with high validity and reliability for detecting PTSD symptoms in elderly Korean veterans. However, further research will be necessary to increase our understanding of PTSD characteristics in diverse groups with different types of trauma. PMID:27482241

  5. Non-invasive biomedical research and diagnostics enabled by innovative compact lasers

    NASA Astrophysics Data System (ADS)

    Litvinova, Karina S.; Rafailov, Ilya E.; Dunaev, Andrey V.; Sokolovski, Sergei G.; Rafailov, Edik U.

    2017-11-01

    For over half a century, laser technology has undergone a technological revolution. These technologies, particularly semiconductor lasers, are employed in a myriad of fields. Optical medical diagnostics, one of the emerging areas of laser application, are on the forefront of application around the world. Optical methods of non- or minimally invasive bio-tissue investigation offer significant advantages over alternative methods, including rapid real-time measurement, non-invasiveness and high resolution (guaranteeing the safety of a patient). These advantages demonstrate the growing success of such techniques. In this review, we will outline the recent status of laser technology applied in the biomedical field, focusing on the various available approaches, particularly utilising compact semiconductor lasers. We will further consider the advancement and integration of several complimentary biophotonic techniques into single multimodal devices, the potential impact of such devices and their future applications. Based on our own studies, we will also cover the simultaneous collection of physiological data with the aid a multifunctional diagnostics system, concentrating on the optimisation of the new technology towards a clinical application. Such data is invaluable for developing algorithms capable of delivering consistent, reliable and meaningful diagnostic information, which can ultimately be employed for the early diagnosis of disease conditions in individuals from around the world.

  6. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    PubMed

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  7. Morphological changes of the hair roots in alopecia areata: a scanning electron microscopic study.

    PubMed

    Karashima, Tadashi; Tsuruta, Daisuke; Hamada, Takahiro; Ishii, Norito; Ono, Fumitake; Ueda, Akihiro; Abe, Toshifumi; Nakama, Takekuni; Dainichi, Teruki; Hashimoto, Takashi

    2013-12-01

    Alopecia areata is a chronic inflammatory condition causing non-scarring patchy hair loss. Diagnosis of alopecia areata is made by clinical observations, hair pluck test and dermoscopic signs. However, because differentiation from other alopecia diseases is occasionally difficult, an invasive diagnostic method using a punch biopsy is performed. In this study, to develop a reliable, less invasive diagnostic method for alopecia areata, we performed scanning electron microscopy of the hair roots of alopecia areata patients. This study identified four patterns of hair morphology specific to alopecia areata: (I) long tapering structure with no accumulation of scales; (II) club-shaped hair root with fine scales; (III) proximal accumulation of scales; and (IV) sharp tapering of the proximal end of hair. On the basis of these results, we can distinguish alopecia areata by scanning electron microscopic observation of the proximal end of the hair shafts. © 2013 Japanese Dermatological Association.

  8. OSA severity assessment based on sleep breathing analysis using ambient microphone.

    PubMed

    Dafna, E; Tarasiuk, A; Zigel, Y

    2013-01-01

    In this paper, an audio-based system for severity estimation of obstructive sleep apnea (OSA) is proposed. The system estimates the apnea-hypopnea index (AHI), which is the average number of apneic events per hour of sleep. This system is based on a Gaussian mixture regression algorithm that was trained and validated on full-night audio recordings. Feature selection process using a genetic algorithm was applied to select the best features extracted from time and spectra domains. A total of 155 subjects, referred to in-laboratory polysomnography (PSG) study, were recruited. Using the PSG's AHI score as a gold-standard, the performances of the proposed system were evaluated using a Pearson correlation, AHI error, and diagnostic agreement methods. Correlation of R=0.89, AHI error of 7.35 events/hr, and diagnostic agreement of 77.3% were achieved, showing encouraging performances and a reliable non-contact alternative method for OSA severity estimation.

  9. Identification of hemoglobin variants by top-down mass spectrometry using selected diagnostic product ions.

    PubMed

    Coelho Graça, Didia; Hartmer, Ralf; Jabs, Wolfgang; Beris, Photis; Clerici, Lorella; Stoermer, Carsten; Samii, Kaveh; Hochstrasser, Denis; Tsybin, Yury O; Scherl, Alexander; Lescuyer, Pierre

    2015-04-01

    Hemoglobin disorder diagnosis is a complex procedure combining several analytical steps. Due to the lack of specificity of the currently used protein analysis methods, the identification of uncommon hemoglobin variants (proteoforms) can become a hard task to accomplish. The aim of this work was to develop a mass spectrometry-based approach to quickly identify mutated protein sequences within globin chain variants. To reach this goal, a top-down electron transfer dissociation mass spectrometry method was developed for hemoglobin β chain analysis. A diagnostic product ion list was established with a color code strategy allowing to quickly and specifically localize a mutation in the hemoglobin β chain sequence. The method was applied to the analysis of rare hemoglobin β chain variants and an (A)γ-β fusion protein. The results showed that the developed data analysis process allows fast and reliable interpretation of top-down electron transfer dissociation mass spectra by nonexpert users in the clinical area.

  10. Nailfold capillaroscopy as a diagnostic and prognostic method in rosacea.

    PubMed

    Fonseca, Gabriela Poglia; Brenner, Fabiane Mulinari; Muller, Carolina de Souza; Wojcik, Adma Lima

    2011-01-01

    There is no appropriate and reliable method of evaluating and monitoring severity in rosacea. To determine the importance of nailfold capillaroscopy as a diagnostic and prognostic method for patients with rosacea. A cross-sectional study where eight patients with rosacea and 8 control subjects were submitted to nailfold capillaroscopy from May to July 2009. We collected clinical data related to gender, age, skin phototype, and rosacea stage according to Plewig and Kligman classification and the classification of the National Rosacea Society. Additionally, we evaluated the progression of the disease and treatment therapies previously used. The majority of the patients evaluated (6 out of 8 patients) had rosacea subtype I (vascular) or erythematotelangiectatic rosacea. The mean duration of the disorder was 5.96 years, and 87.5% of the patients were under treatment with topical metronidazole. Nailfold cappilaroscopy showed that evidence of devascularization was absent in both groups. Nailfold capillaroscopy presents a nonspecific pattern and does not seem to help in the diagnosis or prognosis of rosacea.

  11. Improved localisation of neoclassical tearing modes by combining multiple diagnostic estimates

    NASA Astrophysics Data System (ADS)

    Rapson, C. J.; Fischer, R.; Giannone, L.; Maraschek, M.; Reich, M.; Treutterer, W.; The ASDEX Upgrade Team

    2017-07-01

    Neoclassical tearing modes (NTMs) strongly degrade confinement in tokamaks, and are a leading cause of disruptions. They can be stabilised by targeted electron cyclotron current drive (ECCD), however the effectiveness of ECCD depends strongly on the accuracy or misalignment between ECCD and the NTM. The first step to ensure minimal misalignment is a good estimate of the NTM location. In previous NTM control experiments, three methods have been used independently to estimate the NTM location: the magnetic equilibrium, correlation between magnetic and spatially-resolved temperature fluctuations, and the amplitude response of the NTM to nearby ECCD. This submission describes an algorithm which has been designed to fuse these three estimates into one, taking into account many of the characteristics of each diagnostic. Although the method diverges from standard data fusion methods, results from simulation and experiment confirm that the algorithm achieves its stated goal of providing an estimate that is more reliable and accurate than any of the individual estimates.

  12. The Effects of Q-Matrix Design on Classification Accuracy in the Log-Linear Cognitive Diagnosis Model.

    PubMed

    Madison, Matthew J; Bradshaw, Laine P

    2015-06-01

    Diagnostic classification models are psychometric models that aim to classify examinees according to their mastery or non-mastery of specified latent characteristics. These models are well-suited for providing diagnostic feedback on educational assessments because of their practical efficiency and increased reliability when compared with other multidimensional measurement models. A priori specifications of which latent characteristics or attributes are measured by each item are a core element of the diagnostic assessment design. This item-attribute alignment, expressed in a Q-matrix, precedes and supports any inference resulting from the application of the diagnostic classification model. This study investigates the effects of Q-matrix design on classification accuracy for the log-linear cognitive diagnosis model. Results indicate that classification accuracy, reliability, and convergence rates improve when the Q-matrix contains isolated information from each measured attribute.

  13. The Modified Femoral Neck-Shaft Angle: Age- and Sex-Dependent Reference Values and Reliability Analysis

    PubMed Central

    Jostmeier, Janine; Haneder, Stefan; Dargel, Jens; Eysel, Peer; Lechler, Philipp

    2016-01-01

    Background. The femoral neck-shaft angle (NSA) is of high importance for the diagnostics and treatment of various conditions of the hip. However, rotational effects limit its precision and applicability using plain radiographs. This study introduces a novel method to measure the femoral NSA: the modified NSA (mNSA), possibly being less susceptible against rotational effects compared to the conventional NSA. Patients and Methods. The method of measurement is described and its applicability was tested in 400 pelvis computed tomography scans (800 hips). Age- and gender-dependent reference values are given and intra- and interrater reliability are analyzed. Results. The mean age of all 400 patients (800 hips) was 54.32 years (18–100, SD 22.05 years). The mean mNSA was 147.0° and the 95% confidence interval was 146.7°–147.4°. Differences of the mNSA between sexes, age groups, and sides were nonsignificant. The absolute difference between NSA and mNSA was 16.3° (range 3–31°; SD 4.4°); the correlation was high (0.738; p < 0.001). Overall, the intra- and interrater reliability were excellent for the mNSA. Interpretation. We introduced a novel concept for the analysis of the neck-shaft angle. The high reliability of the measurement has been proven and its robustness to hip rotation was demonstrated. PMID:28070521

  14. The Modified Femoral Neck-Shaft Angle: Age- and Sex-Dependent Reference Values and Reliability Analysis.

    PubMed

    Boese, Christoph Kolja; Frink, Michael; Jostmeier, Janine; Haneder, Stefan; Dargel, Jens; Eysel, Peer; Lechler, Philipp

    2016-01-01

    Background . The femoral neck-shaft angle (NSA) is of high importance for the diagnostics and treatment of various conditions of the hip. However, rotational effects limit its precision and applicability using plain radiographs. This study introduces a novel method to measure the femoral NSA: the modified NSA (mNSA), possibly being less susceptible against rotational effects compared to the conventional NSA. Patients and Methods . The method of measurement is described and its applicability was tested in 400 pelvis computed tomography scans (800 hips). Age- and gender-dependent reference values are given and intra- and interrater reliability are analyzed. Results . The mean age of all 400 patients (800 hips) was 54.32 years (18-100, SD 22.05 years). The mean mNSA was 147.0° and the 95% confidence interval was 146.7°-147.4°. Differences of the mNSA between sexes, age groups, and sides were nonsignificant. The absolute difference between NSA and mNSA was 16.3° (range 3-31°; SD 4.4°); the correlation was high (0.738; p < 0.001). Overall, the intra- and interrater reliability were excellent for the mNSA. Interpretation . We introduced a novel concept for the analysis of the neck-shaft angle. The high reliability of the measurement has been proven and its robustness to hip rotation was demonstrated.

  15. Indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain: protocol of an inter-examiner reliability study among manual therapists.

    PubMed

    van Trijffel, Emiel; Lindeboom, Robert; Bossuyt, Patrick Mm; Schmitt, Maarten A; Lucas, Cees; Koes, Bart W; Oostendorp, Rob Ab

    2014-01-01

    Manual spinal joint mobilisations and manipulations are widely used treatments in patients with neck and low-back pain. Inter-examiner reliability of passive intervertebral motion assessment of the cervical and lumbar spine, perceived as important for indicating these interventions, is poor within a univariable approach. The diagnostic process as a whole in daily practice in manual therapy has a multivariable character, however, in which the use and interpretation of passive intervertebral motion assessment depend on earlier results from the diagnostic process. To date, the inter-examiner reliability among manual therapists of a multivariable diagnostic decision-making process in patients with neck or low-back pain is unknown. This study will be conducted as a repeated-measures design in which 14 pairs of manual therapists independently examine a consecutive series of a planned total of 165 patients with neck or low-back pain presenting in primary care physiotherapy. Primary outcome measure is therapists' decision about whether or not manual spinal joint mobilisations or manipulations, or both, are indicated in each patient, alone or as part of a multimodal treatment. Therapists will largely be free to conduct the full diagnostic process based on their formulated examination objectives. For each pair of therapists, 2×2 tables will be constructed and reliability for the dichotomous decision will be expressed using Cohen's kappa. In addition, observed agreement, prevalence of positive decisions, prevalence index, bias index, and specific agreement in positive and negative decisions will be calculated. Univariable logistic regression analysis of concordant decisions will be performed to explore which demographic, professional, or clinical factors contributed to reliability. This study will provide an estimate of the inter-examiner reliability among manual therapists of indicating spinal joint mobilisations or manipulations in patients with neck or low-back pain based on a multivariable diagnostic reasoning and decision-making process, as opposed to reliability of individual tests. As such, it is proposed as an initial step toward the development of an alternative approach to current classification systems and prediction rules for identifying those patients with spinal disorders that may show a better response to manual therapy which can be incorporated in randomised clinical trials. Potential methodological limitations of this study are discussed.

  16. Temporal Lobe and “Default” Hemodynamic Brain Modes Discriminate Between Schizophrenia and Bipolar Disorder

    PubMed Central

    Calhoun, Vince D.; Maciejewski, Paul K.; Pearlson, Godfrey D.; Kiehl, Kent A.

    2009-01-01

    Schizophrenia and bipolar disorder are currently diagnosed on the basis of psychiatric symptoms and longitudinal course. The determination of a reliable, biologically-based diagnostic indicator of these diseases (a biomarker) could provide the groundwork for developing more rigorous tools for differential diagnosis and treatment assignment. Recently, methods have been used to identify distinct sets of brain regions or “spatial modes” exhibiting temporally coherent brain activity. Using functional magnetic resonance imaging (fMRI) data and a multivariate analysis method, independent component analysis, we combined the temporal lobe and the default modes to discriminate subjects with bipolar disorder, chronic schizophrenia, and healthy controls. Temporal lobe and default mode networks were reliably identified in all participants. Classification results on an independent set of individuals revealed an average sensitivity and specificity of 90 and 95%, respectively. The use of coherent brain networks such as the temporal lobe and default mode networks may provide a more reliable measure of disease state than task-correlated fMRI activity. A combination of two such hemodynamic brain networks shows promise as a biomarker for schizophrenia and bipolar disorder. PMID:17894392

  17. Temporal lobe and "default" hemodynamic brain modes discriminate between schizophrenia and bipolar disorder.

    PubMed

    Calhoun, Vince D; Maciejewski, Paul K; Pearlson, Godfrey D; Kiehl, Kent A

    2008-11-01

    Schizophrenia and bipolar disorder are currently diagnosed on the basis of psychiatric symptoms and longitudinal course. The determination of a reliable, biologically-based diagnostic indicator of these diseases (a biomarker) could provide the groundwork for developing more rigorous tools for differential diagnosis and treatment assignment. Recently, methods have been used to identify distinct sets of brain regions or "spatial modes" exhibiting temporally coherent brain activity. Using functional magnetic resonance imaging (fMRI) data and a multivariate analysis method, independent component analysis, we combined the temporal lobe and the default modes to discriminate subjects with bipolar disorder, chronic schizophrenia, and healthy controls. Temporal lobe and default mode networks were reliably identified in all participants. Classification results on an independent set of individuals revealed an average sensitivity and specificity of 90 and 95%, respectively. The use of coherent brain networks such as the temporal lobe and default mode networks may provide a more reliable measure of disease state than task-correlated fMRI activity. A combination of two such hemodynamic brain networks shows promise as a biomarker for schizophrenia and bipolar disorder.

  18. Reliability of semiquantitative assessment of osteophytes and subchondral cysts on tomosynthesis images by radiologists with different levels of expertise.

    PubMed

    Hayashi, Daichi; Xu, Li; Gusenburg, Jeffrey; Roemer, Frank W; Hunter, David J; Li, Ling; Guermazi, Ali

    2014-01-01

    We aimed to assess reliability of the evaluation of osteophytes and subchondral cysts on tomosynthesis images when read by radiologists with different levels of expertise. Forty subjects aged >40 years had both knees evaluated using tomosynthesis. Images were read by an "experienced" reader (musculoskeletal radiologist with prior experience) and an "inexperienced" reader (radiology resident with no prior experience). Readers graded osteophytes from 0 to 3 and noted the presence/absence of subchondral cysts in four locations of the tibiofemoral joint. Twenty knees were randomly selected and re-read. Inter- and intrareader reliabilities were calculated using overall exact percent agreement and weighted κ statistics. Diagnostic performance of the two readers was compared against magnetic resonance imaging readings by an expert reader (professor of musculoskeletal radiology). The experienced reader showed substantial intrareader reliability for graded reading of osteophytes (90%, κ=0.93), osteophyte detection (95%, κ=0.86) and cyst detection (95%, κ=0.83). The inexperienced reader showed perfect intrareader reliability for cyst detection (100%, κ=1.00) but intrareader reliability for graded reading (75%, κ=0.79) and detection (80%, κ=0.61) of osteophytes was lower than the experienced reader. Inter-reader reliability was 61% (κ=0.72) for graded osteophyte reading, 91% (κ=0.82) for osteophyte detection, and 88% (κ=0.66) for cyst detection. Diagnostic performance of the experienced reader was higher than the inexperienced reader regarding osteophyte detection (sensitivity range 0.74-0.95 vs. 0.54-0.75 for all locations) but diagnostic performance was similar for subchondral cysts. Tomosynthesis offers excellent intrareader reliability regardless of the reader experience, but experience is important for detection of osteophytes.

  19. A Compact, Tunable Near-UV Source for Quantitative Microgravity Combustion Diagnostics

    NASA Technical Reports Server (NTRS)

    Peterson, K. A.; Oh, D. B.

    1999-01-01

    There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.

  20. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance, there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight, and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  1. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  2. Extensions to the Speech Disorders Classification System (SDCS)

    PubMed Central

    Shriberg, Lawrence D.; Fourakis, Marios; Hall, Sheryl D.; Karlsson, Heather B.; Lohmeier, Heather L.; McSweeny, Jane L.; Potter, Nancy L.; Scheer-Cohen, Alison R.; Strand, Edythe A.; Tilkens, Christie M.; Wilson, David L.

    2010-01-01

    This report describes three extensions to a classification system for pediatric speech sound disorders termed the Speech Disorders Classification System (SDCS). Part I describes a classification extension to the SDCS to differentiate motor speech disorders from speech delay and to differentiate among three subtypes of motor speech disorders. Part II describes the Madison Speech Assessment Protocol (MSAP), an approximately two-hour battery of 25 measures that includes 15 speech tests and tasks. Part III describes the Competence, Precision, and Stability Analytics (CPSA) framework, a current set of approximately 90 perceptual- and acoustic-based indices of speech, prosody, and voice used to quantify and classify subtypes of Speech Sound Disorders (SSD). A companion paper, Shriberg, Fourakis, et al. (2010) provides reliability estimates for the perceptual and acoustic data reduction methods used in the SDCS. The agreement estimates in the companion paper support the reliability of SDCS methods and illustrate the complementary roles of perceptual and acoustic methods in diagnostic analyses of SSD of unknown origin. Examples of research using the extensions to the SDCS described in the present report include diagnostic findings for a sample of youth with motor speech disorders associated with galactosemia (Shriberg, Potter, & Strand, 2010) and a test of the hypothesis of apraxia of speech in a group of children with autism spectrum disorders (Shriberg, Paul, Black, & van Santen, 2010). All SDCS methods and reference databases running in the PEPPER (Programs to Examine Phonetic and Phonologic Evaluation Records; [Shriberg, Allen, McSweeny, & Wilson, 2001]) environment will be disseminated without cost when complete. PMID:20831378

  3. Gear Damage Detection Integrating Oil Debris and Vibration Measurement Technologies Developed

    NASA Technical Reports Server (NTRS)

    Gyekeyeski, Andrew L.; Sawicki, Jerzy T.

    2001-01-01

    The development of highly reliable health-monitoring systems is one technology area recommended for reducing the number of helicopter accidents. Helicopter transmission diagnostics are an important part of a helicopter health-monitoring system because helicopters depend on the power train for propulsion, lift, and flight maneuvering. One technique currently being tested for increasing the reliability and decreasing the false alarm rate of current transmission diagnostic tools is the replacement of simple single-sensor limits with multisensor systems integrating different measurement technologies.

  4. Validation and Reliability of a Smartphone Application for the International Prostate Symptom Score Questionnaire: A Randomized Repeated Measures Crossover Study

    PubMed Central

    Shim, Sung Ryul; Sun, Hwa Yeon; Ko, Young Myoung; Chun, Dong-Il; Yang, Won Jae

    2014-01-01

    Background Smartphone-based assessment may be a useful diagnostic and monitoring tool for patients. There have been many attempts to create a smartphone diagnostic tool for clinical use in various medical fields but few have demonstrated scientific validity. Objective The purpose of this study was to develop a smartphone application of the International Prostate Symptom Score (IPSS) and to demonstrate its validity and reliability. Methods From June 2012 to May 2013, a total of 1581 male participants (≥40 years old), with or without lower urinary tract symptoms (LUTS), visited our urology clinic via the health improvement center at Soonchunhyang University Hospital (Republic of Korea) and were enrolled in this study. A randomized repeated measures crossover design was employed using a smartphone application of the IPSS and the conventional paper form of the IPSS. Paired t test under a hypothesis of non-inferior trial was conducted. For the reliability test, the intraclass correlation coefficient (ICC) was measured. Results The total score of the IPSS (P=.289) and each item of the IPSS (P=.157-1.000) showed no differences between the paper version and the smartphone version of the IPSS. The mild, moderate, and severe LUTS groups showed no differences between the two versions of the IPSS. A significant correlation was noted in the total group (ICC=.935, P<.001). The mild, moderate, and severe LUTS groups also showed significant correlations (ICC=.616, .549, and .548 respectively, all P<.001).There was selection bias in this study, as only participants who had smartphones could participate. Conclusions The validity and reliability of the smartphone application version were comparable to the conventional paper version of the IPSS. The smartphone application of the IPSS could be an effective method for measuring lower urinary tract symptoms. PMID:24513507

  5. Diagnosing soft tissue rheumatic disorders of the upper limb in epidemiological studies of vibration-exposed populations

    PubMed Central

    Palmer, Keith T

    2013-01-01

    Objectives To investigate approaches adopted to diagnose soft tissue rheumatic disorders of the upper limb (ULDs) in vibration-exposed populations and in other settings, and to compare their methodological qualities. Methods Systematic searches were made of the Medline, Embase, and CINAHL electronic bibliographic databases, and of various supplementary sources (textbooks, reviews, conference and workshop proceedings, personal files). For vibration-exposed populations, qualifying papers were scored in terms of the provenance of their measuring instruments (adequacy of documentation, standardisation, reliability, criterion-related and content validity). Similar criteria were applied to general proposals for whole diagnostic schemes, and evidence was collated on the test-retest reliability of symptom histories and clinical signs. Results In total, 23 relevant reports were identified concerning vibration-exposed populations - 21 involving symptoms and 9 involving examination/diagnosis. Most of the instruments employed scored poorly in terms of methodological quality. The search also identified, from the wider literature, more than a dozen schemes directed at classifying ULDs, and 18 studies of test-retest reliability of symptoms and physical signs in the upper limb. Findings support the use of the standardised Nordic questionnaire for symptom inquiry and suggest that a range of physical signs can be elicited with reasonable between-observer agreement. Four classification schemes rated well in terms of content validity. One of these had excellent documentation, and one had been tested for repeatability, agreement with an external reference standard, and utility in distinguishing groups that differed in disability, prognosis and associated risk factors. Conclusions Hitherto, most studies of ULDs in vibration-exposed populations have used custom-specified diagnostic methods, poorly documented, and non-stringent in terms of standardisation and supporting evidence of reliability and/or validity. The broader literature contains several question sets and procedures that improve upon this, and offer scope in vibration-exposed populations to diagnose ULDs more systematically. PMID:17909839

  6. [SCAN system--semi-structured interview based on diagnostic criteria].

    PubMed

    Adamowski, Tomasz; Kiejna, Andrzej; Hadryś, Tomasz

    2006-01-01

    This paper presents the main features of contemporary diagnostic systems which are implemented into the SCAN--modern and semi-structured diagnostic interview. The concepts of further development of the classifications, rationale for operationalized diagnostic criteria and for the divisional approach to mental diagnoses will be in focus. The structure and components of SCAN ver. 2.1 (WHO), i.e. Present State Examination--10th edition, Item Group Checklist, Clinical History Schedule, Glossary of Definitions and computer software with the diagnostic algorithm: I-Shell, as well as rules for a reliable use of diagnostic rating scales, will be discussed within the scope of this paper. The materials and training sets necessary for the learning of proper use of the SCAN, especially training sets for SCAN Training Centers and the Reference Manual--a form of guidebook for SCAN shall be introduced. Finally the paper will present evidence that SCAN is an instrument feasible in different cultural settings. Reliability and validity data of SCAN will also be dealt with indicating that SCAN could be widely used in research studies as well as in everyday clinical practice facilitating more detailed diagnostic approach to a patient.

  7. Five systems of psychiatric classification for preschool children: do differences in validity, usefulness and reliability make for competitive or complimentary constellations?

    PubMed

    Postert, Christian; Averbeck-Holocher, Marlies; Beyer, Thomas; Müller, Jörg; Furniss, Tilman

    2009-03-01

    DSM-IV and ICD-10 have limitations in the diagnostic classification of psychiatric disorders at preschool age (0-5 years). The publication of the Diagnostic Classification 0-3 (DC:0-3) in 1994, its basically revised second edition (DC:0-3R) in 2005 and the Research Diagnostic Criteria-Preschool Age (RDC-PA) in 2004 have provided several modifications of these manuals. Taking into account the growing empirical evidence highlighting the need for a diagnostic classification system for psychiatric disorders in preschool children, the main categorical classification systems in preschool psychiatry will be presented and discussed. The paper will focus on issues of validity, usefulness and reliability in DSM-IV, ICD-10, RDC-PA, DC:0-3, and DC:0-3R. The reasons for including or excluding postulated psychiatric disorder categories for preschool children with variable degrees of empirical evidence into the different diagnostic systems will be discussed.

  8. [Inter-rater reliability and validity of the OPD-CA axes structure and conflict].

    PubMed

    Benecke, Cord; Bock, Astrid; Wieser, Elke; Tschiesner, Reinhard; Lochmann, Martha; Küspert, Felicia; Schorn, Robert; Viertler, Bernhard; Steinmayr-Gensluckner, Maria

    2011-01-01

    The manual of the Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) is an instrument meanwhile widespread in the clinical practice to assess psychodynamic dimensions. Publications of inter-rater agreement and validity are still outstanding. This study assessed the interrater-reliability and validity for the axis structure and the axis conflict. 60 adolescents between 14 and 17 years, with and without psychic disorders, were diagnosed with the Operationalized Psychodynamic Diagnostics in childhood and adolescence (Arbeitskreis OPD-KJ, 2007) and SCID-II-interviews and questionnaires. A partial sample of 36 OPD-CA-interviews was the data basis for the assessment of inter-rater agreement. Calculations of validity for axis structure and axis conflict were made with the whole sample. Inter-rater agreement for the axis structure and the axis conflict showed good to very good weighted Kappa coefficients among the trained raters. Validity of the axis structure showed good results. The Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) allows a reliable diagnostic of axis structure and axis conflict, if the ratings are done on the basis of semistructured videotaped interviews by trained raters. The axis structure shows validity, while the results concerning the validity of the axis conflict remain unclear.

  9. Dimensional indicators of generalized anxiety disorder severity for DSM-V.

    PubMed

    Niles, Andrea N; Lebeau, Richard T; Liao, Betty; Glenn, Daniel E; Craske, Michelle G

    2012-03-01

    For DSM-V, simple dimensional measures of disorder severity will accompany diagnostic criteria. The current studies examine convergent validity and test-retest reliability of two potential dimensional indicators of worry severity for generalized anxiety disorder (GAD): percent of the day worried and number of worry domains. In study 1, archival data from diagnostic interviews from a community sample of individuals diagnosed with one or more anxiety disorders (n = 233) were used to assess correlations between percent of the day worried and number of worry domains with other measures of worry severity (clinical severity rating (CSR), age of onset, number of comorbid disorders, Penn state worry questionnaire (PSWQ)) and DSM-IV criteria (excessiveness, uncontrollability and number of physical symptoms). Both measures were significantly correlated with CSR and number of comorbid disorders, and with all three DSM-IV criteria. In study 2, test-retest reliability of percent of the day worried and number of worry domains were compared to test-retest reliability of DSM-IV diagnostic criteria in a non-clinical sample of undergraduate students (n = 97) at a large west coast university. All measures had low test-retest reliability except percent of the day worried, which had moderate test-retest reliability. Findings suggest that these two indicators capture worry severity, and percent of the day worried may be the most reliable existing indicator. These measures may be useful as dimensional measures for DSM-V. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Research Priorities in the Utilization and Interpretation of Diagnostic Imaging: Education, Assessment, and Competency.

    PubMed

    Lewiss, Resa E; Chan, Wilma; Sheng, Alexander Y; Soto, Jorge; Castro, Alexandra; Meltzer, Andrew C; Cherney, Alan; Kumaravel, Manickam; Cody, Dianna; Chen, Esther H

    2015-12-01

    The appropriate selection and accurate interpretation of diagnostic imaging is a crucial skill for emergency practitioners. To date, the majority of the published literature and research on competency assessment comes from the subspecialty of point-of-care ultrasound. A group of radiologists, physicists, and emergency physicians convened at the 2015 Academic Emergency Medicine consensus conference to discuss and prioritize a research agenda related to education, assessment, and competency in ordering and interpreting diagnostic imaging. A set of questions for the continued development of an educational curriculum on diagnostic imaging for trainees and competency assessment using specific assessment methods based on current best practices was delineated. The research priorities were developed through an iterative consensus-driven process using a modified nominal group technique that culminated in an in-person breakout session. The four recommendations are: 1) develop a diagnostic imaging curriculum for emergency medicine (EM) residency training; 2) develop, study, and validate tools to assess competency in diagnostic imaging interpretation; 3) evaluate the role of simulation in education, assessment, and competency measures for diagnostic imaging; 4) study is needed regarding the American College of Radiology Appropriateness Criteria, an evidence-based peer-reviewed resource in determining the use of diagnostic imaging, to maximize its value in EM. In this article, the authors review the supporting reliability and validity evidence and make specific recommendations for future research on the education, competency, and assessment of learning diagnostic imaging. © 2015 by the Society for Academic Emergency Medicine.

  11. Noninvasive measurement of burn wound depth applying infrared thermal imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Jaspers, Mariëlle E.; Maltha, Ilse M.; Klaessens, John H.; Vet, Henrica C.; Verdaasdonk, Rudolf M.; Zuijlen, Paul P.

    2016-02-01

    In burn wounds early discrimination between the different depths plays an important role in the treatment strategy. The remaining vasculature in the wound determines its healing potential. Non-invasive measurement tools that can identify the vascularization are therefore considered to be of high diagnostic importance. Thermography is a non-invasive technique that can accurately measure the temperature distribution over a large skin or tissue area, the temperature is a measure of the perfusion of that area. The aim of this study was to investigate the clinimetric properties (i.e. reliability and validity) of thermography for measuring burn wound depth. In a cross-sectional study with 50 burn wounds of 35 patients, the inter-observer reliability and the validity between thermography and Laser Doppler Imaging were studied. With ROC curve analyses the ΔT cut-off point for different burn wound depths were determined. The inter-observer reliability, expressed by an intra-class correlation coefficient of 0.99, was found to be excellent. In terms of validity, a ΔT cut-off point of 0.96°C (sensitivity 71%; specificity 79%) differentiates between a superficial partial-thickness and deep partial-thickness burn. A ΔT cut-off point of -0.80°C (sensitivity 70%; specificity 74%) could differentiate between a deep partial-thickness and a full-thickness burn wound. This study demonstrates that thermography is a reliable method in the assessment of burn wound depths. In addition, thermography was reasonably able to discriminate among different burn wound depths, indicating its potential use as a diagnostic tool in clinical burn practice.

  12. The Standard for Clinicians’ Interview in Psychiatry (SCIP): A Clinician-administered Tool with Categorical, Dimensional, and Numeric Output—Conceptual Development, Design, and Description of the SCIP

    PubMed Central

    Nasrallah, Henry; Muvvala, Srinivas; El-Missiry, Ahmed; Mansour, Hader; Hill, Cheryl; Elswick, Daniel; Price, Elizabeth C.

    2016-01-01

    Existing standardized diagnostic interviews (SDIs) were designed for researchers and produce mainly categorical diagnoses. There is an urgent need for a clinician-administered tool that produces dimensional measures, in addition to categorical diagnoses. The Standard for Clinicians’ Interview in Psychiatry (SCIP) is a method of assessment of psychopathology for adults. It is designed to be administered by clinicians and includes the SCIP manual and the SCIP interview. Clinicians use the SCIP questions and rate the responses according to the SCIP manual rules. Clinicians use the patient’s responses to questions, observe the patient’s behaviors and make the final rating of the various signs and symptoms assessed. The SCIP method of psychiatric assessment has three components: 1) the SCIP interview (dimensional) component, 2) the etiological component, and 3) the disorder classification component. The SCIP produces three main categories of clinical data: 1) a diagnostic classification of psychiatric disorders, 2) dimensional scores, and 3) numeric data. The SCIP provides diagnoses consistent with criteria from editions of the Diagnostic and Statistical Manual (DSM) and International Classification of Disease (ICD). The SCIP produces 18 dimensional measures for key psychiatric signs or symptoms: anxiety, posttraumatic stress, obsessions, compulsions, depression, mania, suicidality, suicidal behavior, delusions, hallucinations, agitation, disorganized behavior, negativity, catatonia, alcohol addiction, drug addiction, attention, and hyperactivity. The SCIP produces numeric severity data for use in either clinical care or research. The SCIP was shown to be a valid and reliable assessment tool, and the validity and reliability results were published in 2014 and 2015. The SCIP is compatible with personalized psychiatry research and is in line with the Research Domain Criteria framework. PMID:27800284

  13. The Standard for Clinicians' Interview in Psychiatry (SCIP): A Clinician-administered Tool with Categorical, Dimensional, and Numeric Output-Conceptual Development, Design, and Description of the SCIP.

    PubMed

    Aboraya, Ahmed; Nasrallah, Henry; Muvvala, Srinivas; El-Missiry, Ahmed; Mansour, Hader; Hill, Cheryl; Elswick, Daniel; Price, Elizabeth C

    2016-01-01

    Existing standardized diagnostic interviews (SDIs) were designed for researchers and produce mainly categorical diagnoses. There is an urgent need for a clinician-administered tool that produces dimensional measures, in addition to categorical diagnoses. The Standard for Clinicians' Interview in Psychiatry (SCIP) is a method of assessment of psychopathology for adults. It is designed to be administered by clinicians and includes the SCIP manual and the SCIP interview. Clinicians use the SCIP questions and rate the responses according to the SCIP manual rules. Clinicians use the patient's responses to questions, observe the patient's behaviors and make the final rating of the various signs and symptoms assessed. The SCIP method of psychiatric assessment has three components: 1) the SCIP interview (dimensional) component, 2) the etiological component, and 3) the disorder classification component. The SCIP produces three main categories of clinical data: 1) a diagnostic classification of psychiatric disorders, 2) dimensional scores, and 3) numeric data. The SCIP provides diagnoses consistent with criteria from editions of the Diagnostic and Statistical Manual (DSM) and International Classification of Disease (ICD). The SCIP produces 18 dimensional measures for key psychiatric signs or symptoms: anxiety, posttraumatic stress, obsessions, compulsions, depression, mania, suicidality, suicidal behavior, delusions, hallucinations, agitation, disorganized behavior, negativity, catatonia, alcohol addiction, drug addiction, attention, and hyperactivity. The SCIP produces numeric severity data for use in either clinical care or research. The SCIP was shown to be a valid and reliable assessment tool, and the validity and reliability results were published in 2014 and 2015. The SCIP is compatible with personalized psychiatry research and is in line with the Research Domain Criteria framework.

  14. Enhancing malaria diagnosis through microfluidic cell enrichment and magnetic resonance relaxometry detection

    NASA Astrophysics Data System (ADS)

    Fook Kong, Tian; Ye, Weijian; Peng, Weng Kung; Wei Hou, Han; Marcos; Preiser, Peter Rainer; Nguyen, Nam-Trung; Han, Jongyoon

    2015-06-01

    Despite significant advancements over the years, there remains an urgent need for low cost diagnostic approaches that allow for rapid, reliable and sensitive detection of malaria parasites in clinical samples. Our previous work has shown that magnetic resonance relaxometry (MRR) is a potentially highly sensitive tool for malaria diagnosis. A key challenge for making MRR based malaria diagnostics suitable for clinical testing is the fact that MRR baseline fluctuation exists between individuals, making it difficult to detect low level parasitemia. To overcome this problem, it is important to establish the MRR baseline of each individual while having the ability to reliably determine any changes that are caused by the infection of malaria parasite. Here we show that an approach that combines the use of microfluidic cell enrichment with a saponin lysis before MRR detection can overcome these challenges and provide the basis for a highly sensitive and reliable diagnostic approach of malaria parasites. Importantly, as little as 0.0005% of ring stage parasites can be detected reliably, making this ideally suited for the detection of malaria parasites in peripheral blood obtained from patients. The approaches used here are envisaged to provide a new malaria diagnosis solution in the near future.

  15. The ICD‐11 developmental field study of reliability of diagnoses of high‐burden mental disorders: results among adult patients in mental health settings of 13 countries

    PubMed Central

    Reed, Geoffrey M.; Sharan, Pratap; Rebello, Tahilia J.; Keeley, Jared W.; Elena Medina‐Mora, María; Gureje, Oye; Luis Ayuso‐Mateos, José; Kanba, Shigenobu; Khoury, Brigitte; Kogan, Cary S.; Krasnov, Valery N.; Maj, Mario; de Jesus Mari, Jair; Stein, Dan J.; Zhao, Min; Akiyama, Tsuyoshi; Andrews, Howard F.; Asevedo, Elson; Cheour, Majda; Domínguez‐Martínez, Tecelli; El‐Khoury, Joseph; Fiorillo, Andrea; Grenier, Jean; Gupta, Nitin; Kola, Lola; Kulygina, Maya; Leal‐Leturia, Itziar; Luciano, Mario; Lusu, Bulumko; Nicolas, J.; Martínez‐López, I.; Matsumoto, Chihiro; Umukoro Onofa, Lucky; Paterniti, Sabrina; Purnima, Shivani; Robles, Rebeca; Sahu, Manoj K.; Sibeko, Goodman; Zhong, Na; First, Michael B.; Gaebel, Wolfgang; Lovell, Anne M.; Maruta, Toshimasa; Roberts, Michael C.; Pike, Kathleen M.

    2018-01-01

    Reliable, clinically useful, and globally applicable diagnostic classification of mental disorders is an essential foundation for global mental health. The World Health Organization (WHO) is nearing completion of the 11th revision of the International Classification of Diseases and Related Health Problems (ICD‐11). The present study assessed inter‐diagnostician reliability of mental disorders accounting for the greatest proportion of global disease burden and the highest levels of service utilization – schizophrenia and other primary psychotic disorders, mood disorders, anxiety and fear‐related disorders, and disorders specifically associated with stress – among adult patients presenting for treatment at 28 participating centers in 13 countries. A concurrent joint‐rater design was used, focusing specifically on whether two clinicians, relying on the same clinical information, agreed on the diagnosis when separately applying the ICD‐11 diagnostic guidelines. A total of 1,806 patients were assessed by 339 clinicians in the local language. Intraclass kappa coefficients for diagnoses weighted by site and study prevalence ranged from 0.45 (dysthymic disorder) to 0.88 (social anxiety disorder) and would be considered moderate to almost perfect for all diagnoses. Overall, the reliability of the ICD‐11 diagnostic guidelines was superior to that previously reported for equivalent ICD‐10 guidelines. These data provide support for the suitability of the ICD‐11 diagnostic guidelines for implementation at a global level. The findings will inform further revision of the ICD‐11 diagnostic guidelines prior to their publication and the development of programs to support professional training and implementation of the ICD‐11 by WHO member states. PMID:29856568

  16. The ICD-11 developmental field study of reliability of diagnoses of high-burden mental disorders: results among adult patients in mental health settings of 13 countries.

    PubMed

    Reed, Geoffrey M; Sharan, Pratap; Rebello, Tahilia J; Keeley, Jared W; Elena Medina-Mora, María; Gureje, Oye; Luis Ayuso-Mateos, José; Kanba, Shigenobu; Khoury, Brigitte; Kogan, Cary S; Krasnov, Valery N; Maj, Mario; de Jesus Mari, Jair; Stein, Dan J; Zhao, Min; Akiyama, Tsuyoshi; Andrews, Howard F; Asevedo, Elson; Cheour, Majda; Domínguez-Martínez, Tecelli; El-Khoury, Joseph; Fiorillo, Andrea; Grenier, Jean; Gupta, Nitin; Kola, Lola; Kulygina, Maya; Leal-Leturia, Itziar; Luciano, Mario; Lusu, Bulumko; Nicolas, J; Martínez-López, I; Matsumoto, Chihiro; Umukoro Onofa, Lucky; Paterniti, Sabrina; Purnima, Shivani; Robles, Rebeca; Sahu, Manoj K; Sibeko, Goodman; Zhong, Na; First, Michael B; Gaebel, Wolfgang; Lovell, Anne M; Maruta, Toshimasa; Roberts, Michael C; Pike, Kathleen M

    2018-06-01

    Reliable, clinically useful, and globally applicable diagnostic classification of mental disorders is an essential foundation for global mental health. The World Health Organization (WHO) is nearing completion of the 11th revision of the International Classification of Diseases and Related Health Problems (ICD-11). The present study assessed inter-diagnostician reliability of mental disorders accounting for the greatest proportion of global disease burden and the highest levels of service utilization - schizophrenia and other primary psychotic disorders, mood disorders, anxiety and fear-related disorders, and disorders specifically associated with stress - among adult patients presenting for treatment at 28 participating centers in 13 countries. A concurrent joint-rater design was used, focusing specifically on whether two clinicians, relying on the same clinical information, agreed on the diagnosis when separately applying the ICD-11 diagnostic guidelines. A total of 1,806 patients were assessed by 339 clinicians in the local language. Intraclass kappa coefficients for diagnoses weighted by site and study prevalence ranged from 0.45 (dysthymic disorder) to 0.88 (social anxiety disorder) and would be considered moderate to almost perfect for all diagnoses. Overall, the reliability of the ICD-11 diagnostic guidelines was superior to that previously reported for equivalent ICD-10 guidelines. These data provide support for the suitability of the ICD-11 diagnostic guidelines for implementation at a global level. The findings will inform further revision of the ICD-11 diagnostic guidelines prior to their publication and the development of programs to support professional training and implementation of the ICD-11 by WHO member states. © 2018 World Psychiatric Association.

  17. Reliability and diagnostic accuracy of history and physical examination for diagnosing glenoid labral tears.

    PubMed

    Walsworth, Matthew K; Doukas, William C; Murphy, Kevin P; Mielcarek, Billie J; Michener, Lori A

    2008-01-01

    Glenoid labral tears provide a diagnostic challenge. Combinations of items in the patient history and physical examination will provide stronger diagnostic accuracy to suggest the presence or absence of glenoid labral tear than will individual items. Cohort study (diagnosis); Level of evidence, 1. History and examination findings in patients with shoulder pain (N = 55) were compared with arthroscopic findings to determine diagnostic accuracy and intertester reliability. The intertester reliability of the crank, anterior slide, and active compression tests was 0.20 to 0.24. A combined history of popping or catching and positive crank or anterior slide results yielded specificities of 0.91 and 1.00 and positive likelihood ratios of 3.0 and infinity, respectively. A positive anterior slide result combined with either a positive active compression or crank result yielded specificities of 0.91 and positive likelihood ratio of 2.75 and 3.75, respectively. Requiring only a single positive finding in the combination of popping or catching and the anterior slide or crank yielded sensitivities of 0.82 and 0.89 and negative likelihood ratios of 0.31 and 0.33, respectively. The diagnostic accuracy of individual tests in previous studies is quite variable, which may be explained in part by the modest reliability of these tests. The combination of popping or catching with a positive crank or anterior slide result or a positive anterior slide result with a positive active compression or crank test result suggests the presence of a labral tear. The combined absence of popping or catching and a negative anterior slide or crank result suggests the absence of a labral tear.

  18. SLOWLY REPEATED EVOKED PAIN (SREP) AS A MARKER OF CENTRAL SENSITIZATION IN FIBROMYALGIA: DIAGNOSTIC ACCURACY AND RELIABILITY IN COMPARISON WITH TEMPORAL SUMMATION OF PAIN.

    PubMed

    de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A

    2018-05-01

    This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.

  19. Comparing paraffined and deparaffinized breast cancer tissue samples and an analysis of Raman spectroscopy and infrared methods

    NASA Astrophysics Data System (ADS)

    Depciuch, J.; Kaznowska, E.; Szmuc, K.; Zawlik, I.; Cholewa, M.; Heraud, P.; Cebulski, J.

    2016-05-01

    Breast cancer makes up a quarter of all cancer in women, which is why research into new diagnostic methods and sample preparations need to be developed at an accelerated pace. Researchers are looking for diagnostic tools to detect when an individual has cancer cells and use that information to see what measurements and approaches can be used to take further diagnostic steps. The most common method of sample preparation is the imbibing of tumor tissue in paraffin, which can produce a background for spectroscopic measurements in the range of 500-3500 cm-1. In this study we demonstrated that proper preparation of paraffin-embedded specimens and the measurement methodology can eliminate paraffin vibration, as was done in the work Depciuch et al. 2015. Thanks to this spectroscopic technique there may become a reliable and accurate method of diagnosing breast cancer based on the evidence found from the prepared samples. The study compared the results obtained through Raman spectroscopy and FTIR (Fourier Transform Infrared) measurements of healthy and cancerous breast tissues that were either embedded in paraffin or deparaffinized. The resulting spectrum and accurate analysis led to the conclusion that the appropriate measurement of the background and the elimination of peaks from the paraffin had the greatest impact on the reliability of results. Furthermore, after the accurate, detailed studies FTIR and Raman spectroscopy on samples of breast tissue that were deparaffinized or embedded in paraffin, including a complete analysis of the peak after transformation Kramers-Kröning (KK), it was found that sample preparation did not affect the result obtained by measuring the reflectance in the mid-infrared range, and that this only had a minimal effect relating to the intensity obtained by the measurement of the Raman peak. Only in special cases, when Raman spectroscopic methods are used for research to find the peculiarities of the spectra, are deparaffinization recommended, in order to attain more detailed results that could be crucial in understanding the process of carcinogenesis.

  20. Translating the semi-structured assessment for drug dependence and alcoholism in the Western Pacific: rationale, study design and reliability of alcohol dependence.

    PubMed

    Quinn, Amity E; Rosen, Rochelle K; McGeary, John E; Amoa, Francine; Kranzler, Henry R; Francazio, Sarah; McGarvey, Stephen T; Swift, Robert M

    2014-01-01

    The aims of this study were to develop a bilingual version of the Semi-Structured Assessment for Drug Dependence and Alcoholism (SSADDA) in English and Samoan and determine the reliability of assessments of alcohol dependence in American Samoa. The study consisted of development and reliability-testing phases. In the development phase, the SSADDA alcohol module was translated and the translation was evaluated through cognitive interviews. In the reliability-testing phase, the bilingual SSADDA was administered to 40 ethnic Samoans, including a sub-sample of 26 individuals who were retested. Cognitive interviews indicated the initial translation was culturally and linguistically appropriate except items pertaining to alcohol tolerance, which were modified to reflect Samoan concepts. SSADDA reliability testing indicated diagnoses of DSM-III-R and DSM-IV alcohol dependence were reliable. Reliability varied by language of administration. The English/Samoan version of the SSADDA is appropriate for the diagnosis of DSM-III-R alcohol dependence, which may be useful in advancing research and public health efforts to address alcohol problems in American Samoa and the Western Pacific. The translation methods may inform researchers translating diagnostic and assessment tools into different languages and cultures. © The Author 2014. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  1. Reliability of widefield nailfold capillaroscopy and video capillaroscopy in the assessment of patients with Raynaud’s phenomenon.

    PubMed

    Sekiyama, Juliana Y; Camargo, Cintia Z; Eduardo, Luís; Andrade, C; Kayser, Cristiane

    2013-11-01

    To analyze the diagnostic performance and reliability of different parameters evaluated by widefield nailfold capillaroscopy (NFC) with those obtained by video capillaroscopy in patients with Raynaud’s phenomenon (RP). Two hundred fifty-two individuals were assessed, including 101 systemic sclerosis (SSc; scleroderma) patients,61 patients with undifferentiated connective tissue disease, 37 patients with primary RP, and 53 controls. Widefield NFC was performed using a stereomicroscope under 10–25 x magnification and direct measurement of all parameters. Video capillaroscopy was performed under 200 x magnification, with the acquirement of 32 images per individual (4 fields per finger in 8 fingers). The following parameters were analyzed in 8 fingers of the hands (excluding thumbs) by both methods: number of capillaries/mm, number of enlarged and giant capillaries, microhemorrhages, and avascular score.Intra- and interobserver reliability was evaluated by performing both examinations in 20 individuals on 2 different days and by 2 long-term experienced observers. There was a significant correlation (P < 0.000) between widefield NFC and video capillaroscopy in the comparison of all parameters. Kappa values and intraclass correlation coefficient analysis showed excellent intra- and interobserver reproducibility for all parameters evaluated by widefield NFC and video capillaroscopy. Bland-Altman analysis showed high agreement of all parameters evaluated in both methods. According to receiver operating characteristic curve analysis, both methods showed a similar performance in discriminating SSc patients from controls. Widefield NFC and video capillaroscopy are reliable and accurate methods and can be used equally for assessing peripheral microangiopathy in RP and SSc patients. Nonetheless, the high reliability obtained may not be similar for less experienced examiners.

  2. Diagnostic and model dependent uncertainty of simulated Tibetan permafrost area

    NASA Astrophysics Data System (ADS)

    Wang, W.; Rinke, A.; Moore, J. C.; Cui, X.; Ji, D.; Li, Q.; Zhang, N.; Wang, C.; Zhang, S.; Lawrence, D. M.; McGuire, A. D.; Zhang, W.; Delire, C.; Koven, C.; Saito, K.; MacDougall, A.; Burke, E.; Decharme, B.

    2015-03-01

    We perform a land surface model intercomparison to investigate how the simulation of permafrost area on the Tibetan Plateau (TP) varies between 6 modern stand-alone land surface models (CLM4.5, CoLM, ISBA, JULES, LPJ-GUESS, UVic). We also examine the variability in simulated permafrost area and distribution introduced by 5 different methods of diagnosing permafrost (from modeled monthly ground temperature, mean annual ground and air temperatures, air and surface frost indexes). There is good agreement (99-135 x 104 km2) between the two diagnostic methods based on air temperature which are also consistent with the best current observation-based estimate of actual permafrost area (101 x 104 km2). However the uncertainty (1-128 x 104 km2) using the three methods that require simulation of ground temperature is much greater. Moreover simulated permafrost distribution on TP is generally only fair to poor for these three methods (diagnosis of permafrost from monthly, and mean annual ground temperature, and surface frost index), while permafrost distribution using air temperature based methods is generally good. Model evaluation at field sites highlights specific problems in process simulations likely related to soil texture specification and snow cover. Models are particularly poor at simulating permafrost distribution using definition that soil temperature remains at or below 0°C for 24 consecutive months, which requires reliable simulation of both mean annual ground temperatures and seasonal cycle, and hence is relatively demanding. Although models can produce better permafrost maps using mean annual ground temperature and surface frost index, analysis of simulated soil temperature profiles reveals substantial biases. The current generation of land surface models need to reduce biases in simulated soil temperature profiles before reliable contemporary permafrost maps and predictions of changes in permafrost distribution can be made for the Tibetan Plateau.

  3. Enhanced definitions of intimate partner violence for DSM-5 and ICD-11 may promote improved screening and treatment.

    PubMed

    Heyman, Richard E; Slep, Amy M Smith; Foran, Heather M

    2015-03-01

    Nuanced, multifaceted, and content valid diagnostic criteria for intimate partner violence (IPV) have been created and can be used reliably in the field even by those with little-to-no clinical training/background. The use of such criteria such as these would likely lead to more reliable decision making in the field and more consistency across studies. Further, interrater agreement was higher than that usually reported for individual mental disorders. This paper will provide an overview of (a) IPV's scope and impact; (b) the reliable and valid diagnostic criteria that have been used and the adaptation of these criteria inserted in the latest Diagnostic and Statistical Manual of Mental Disorders (DSM) and another adaptation proposed for the forthcoming International Statistical Classification of Diseases and Related Health Problems (ICD); (c) suggestions for screening of IPV in primary care settings; (d) interventions for IPV; and (e) suggested steps toward globally accepted programs. © 2015 Family Process Institute.

  4. Use of Fine Needle Aspirate from Peripheral Nerves of Pure-neural Leprosy for Cytology and Polymerase Chain Reaction to Confirm the Diagnosis: A Follow-up Study of 4 Years

    PubMed Central

    De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip

    2017-01-01

    Background: Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. Aim: This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. Materials and Methods: All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. Results: A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. Conclusion: The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL. PMID:29263539

  5. Narrative review: should teaching of the respiratory physical examination be restricted only to signs with proven reliability and validity?

    PubMed

    Benbassat, Jochanan; Baumal, Reuben

    2010-08-01

    To review the reported reliability (reproducibility, inter-examiner agreement) and validity (sensitivity, specificity and likelihood ratios) of respiratory physical examination (PE) signs, and suggest an approach to teaching these signs to medical students. Review of the literature. We searched Paper Chase between 1966 and June 2009 to identify and evaluate published studies on the diagnostic accuracy of respiratory PE signs. Most studies have reported low to fair reliability and sensitivity values. However, some studies have found high specificites for selected PE signs. None of the studies that we reviewed adhered to all of the STARD criteria for reporting diagnostic accuracy. Possible flaws in study designs may have led to underestimates of the observed diagnostic accuracy of respiratory PE signs. The reported poor reliabilities may have been due to differences in the PE skills of the participating examiners, while the sensitivities may have been confounded by variations in the severity of the diseases of the participating patients. IMPLICATION FOR PRACTICE AND MEDICAL EDUCATION: Pending the results of properly controlled studies, the reported poor reliability and sensitivity of most respiratory PE signs do not necessarily detract from their clinical utility. Therefore, we believe that a meticulously performed respiratory PE, which aims to explore a diagnostic hypothesis, as opposed to a PE that aims to detect a disease in an asymptomatic person, remains a cornerstone of clinical practice. We propose teaching the respiratory PE signs according to their importance, beginning with signs of life-threatening conditions and those that have been reported to have a high specificity, and ending with signs that are "nice to know," but are no longer employed because of the availability of more easily performed tests.

  6. Understanding the reliability of diagnostic variables in a Chinese Medicine examination.

    PubMed

    O'Brien, Kylie A; Abbas, Estelle; Zhang, Jiansheng; Guo, Zhi-Xin; Luo, Ruizhi; Bensoussan, Alan; Komesaroff, Paul A

    2009-07-01

    The question of the objectivity of the clinical examination has been raised in relation to Western and non-Western medical systems. Western practitioners are often skeptical about Traditional Chinese Medicine (TCM), on the basis that its diagnostic variables and subcategories of disease appear subjective and not repeatable. We conducted a study investigating the reproducibility of individual diagnostic observations within three of the four diagnostic methods used in a TCM examination: inspection, palpation, and auscultation. Three TCM practitioners participated in the study, and examined 45 adults who had mild-to-moderate hypercholesterolemia but were otherwise healthy. Results indicated that while there are certain features of the TCM system that are highly objective and repeatable, such as detection of the presence of shen, character of breath sounds, and pulse speed, there are other features that are subjective and unreliable, such as color under the eyes and tongue body color. This poses a challenge for TCM practitioners to improve their clinical practice and demonstrates to Western medical practitioners that TCM does in part rest on a rigorous and objective empirical basis.

  7. Microfluidic diagnostics for low-resource settings

    NASA Astrophysics Data System (ADS)

    Hawkins, Kenneth R.; Weigl, Bernhard H.

    2010-02-01

    Diagnostics for low-resource settings need to be foremost inexpensive, but also accurate, reliable, rugged and suited to the contexts of the developing world. Diagnostics for global health, based on minimally-instrumented, microfluidicsbased platforms employing low-cost disposables, has become a very active research area recently-thanks, in part, to new funding from the Bill & Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based assays for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic-acid amplification have been developed. Regardless of platform, however, the search for truly low-cost manufacturing methods that would enable affordable systems (at volume, in the appropriate context) remains a significant challenge. Here we give an overview of existing platform development efforts, present some original research in this area at PATH, and reiterate a call to action for more.

  8. About increasing informativity of diagnostic system of asynchronous electric motor by extracting additional information from values of consumed current parameter

    NASA Astrophysics Data System (ADS)

    Zhukovskiy, Y.; Korolev, N.; Koteleva, N.

    2018-05-01

    This article is devoted to expanding the possibilities of assessing the technical state of the current consumption of asynchronous electric drives, as well as increasing the information capacity of diagnostic methods, in conditions of limited access to equipment and incompleteness of information. The method of spectral analysis of the electric drive current can be supplemented by an analysis of the components of the current of the Park's vector. The research of the hodograph evolution in the moment of appearance and development of defects was carried out using the example of current asymmetry in the phases of an induction motor. The result of the study is the new diagnostic parameters of the asynchronous electric drive. During the research, it was proved that the proposed diagnostic parameters allow determining the type and level of the defect. At the same time, there is no need to stop the equipment and taky it out of service for repair. Modern digital control and monitoring systems can use the proposed parameters based on the stator current of an electrical machine to improve the accuracy and reliability of obtaining diagnostic patterns and predicting their changes in order to improve the equipment maintenance systems. This approach can also be used in systems and objects where there are significant parasitic vibrations and unsteady loads. The extraction of useful information can be carried out in electric drive systems in the structure of which there is a power electric converter.

  9. Use of Fine Needle Aspirate from Peripheral Nerves of Pure-neural Leprosy for Cytology and Polymerase Chain Reaction to Confirm the Diagnosis: A Follow-up Study of 4 Years.

    PubMed

    De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip

    2017-01-01

    Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL.

  10. Comparative evaluation of matrix-assisted laser desorption ionisation-time of flight mass spectrometry and conventional phenotypic-based methods for identification of clinically important yeasts in a UK-based medical microbiology laboratory.

    PubMed

    Fatania, Nita; Fraser, Mark; Savage, Mike; Hart, Jason; Abdolrasouli, Alireza

    2015-12-01

    Performance of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) was compared in a side-by side-analysis with conventional phenotypic methods currently in use in our laboratory for identification of yeasts in a routine diagnostic setting. A diverse collection of 200 clinically important yeasts (19 species, five genera) were identified by both methods using standard protocols. Discordant or unreliable identifications were resolved by sequencing of the internal transcribed spacer region of the rRNA gene. MALDI-TOF and conventional methods were in agreement for 182 isolates (91%) with correct identification to species level. Eighteen discordant results (9%) were due to rarely encountered species, hence the difficulty in their identification using traditional phenotypic methods. MALDI-TOF MS enabled rapid, reliable and accurate identification of clinically important yeasts in a routine diagnostic microbiology laboratory. Isolates with rare, unusual or low probability identifications should be confirmed using robust molecular methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. A Validity and Reliability Update on the Informal Reading Inventory with Suggestions for Improvement.

    ERIC Educational Resources Information Center

    Klesius, Janell P.; Homan, Susan P.

    1985-01-01

    The article reviews validity and reliability studies on the informal reading inventory, a diagnostic instrument to identify reading grade-level placement and strengths and weaknesses in work recognition and comprehension. Gives suggestions to improve the validity and reliability of existing inventories and to evaluate them in newly published…

  12. Validity and reliability of the Diagnostic Adaptive Behaviour Scale.

    PubMed

    Tassé, M J; Schalock, R L; Balboni, G; Spreat, S; Navas, P

    2016-01-01

    The Diagnostic Adaptive Behaviour Scale (DABS) is a new standardised adaptive behaviour measure that provides information for evaluating limitations in adaptive behaviour for the purpose of determining a diagnosis of intellectual disability. This article presents validity evidence and reliability data for the DABS. Validity evidence was based on comparing DABS scores with scores obtained on the Vineland Adaptive Behaviour Scale, second edition. The stability of the test scores was measured using a test and retest, and inter-rater reliability was assessed by computing the inter-respondent concordance. The DABS convergent validity coefficients ranged from 0.70 to 0.84, while the test-retest reliability coefficients ranged from 0.78 to 0.95, and the inter-rater concordance as measured by intraclass correlation coefficients ranged from 0.61 to 0.87. All obtained validity and reliability indicators were strong and comparable with the validity and reliability coefficients of the most commonly used adaptive behaviour instruments. These results and the advantages of the DABS for clinician and researcher use are discussed. © 2015 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  13. Reliability and Validity of Prototype Diagnosis for Adolescent Psychopathology.

    PubMed

    Haggerty, Greg; Zodan, Jennifer; Mehra, Ashwin; Zubair, Ayyan; Ghosh, Krishnendu; Siefert, Caleb J; Sinclair, Samuel J; DeFife, Jared

    2016-04-01

    The current study investigated the interrater reliability and validity of prototype ratings of 5 common adolescent psychiatric disorders: attention-deficit/hyperactivity disorder, conduct disorder, major depressive disorder, generalized anxiety disorder, and posttraumatic stress disorder. One hundred fifty-seven adolescent inpatient participants consented to participate in this study. We compared ratings from 2 inpatient clinicians, blinded to each other's ratings and patient measures, after their separate initial diagnostic interview to assess interrater reliability. Prototype ratings completed by clinicians after their initial diagnostic interview with adolescent inpatients and outpatients were compared with patient-reported behavior problems and parents' report of their child's behavioral problems. Prototype ratings demonstrated good interrater reliability. Clinicians' prototype ratings showed predicted relationships with patient-reported behavior problems and parent-reported behavior problems. Prototype matching seems to be a possible alternative for psychiatric diagnosis. Prototype ratings showed good interrater reliability based on clinicians unique experiences with the patient (as opposed to video-/audio-recorded material) with no training.

  14. Diagnosing Autism Spectrum Disorders in Adults: The Use of Autism Diagnostic Observation Schedule (ADOS) Module 4

    ERIC Educational Resources Information Center

    Bastiaansen, Jojanneke A.; Meffert, Harma; Hein, Simone; Huizinga, Petra; Ketelaars, Cees; Pijnenborg, Marieke; Bartels, Arnold; Minderaa, Ruud; Keysers, Christian; de Bildt, Annelies

    2011-01-01

    Autism Diagnostic Observation Schedule (ADOS) module 4 was investigated in an independent sample of high-functioning adult males with an autism spectrum disorder (ASD) compared to three specific diagnostic groups: schizophrenia, psychopathy, and typical development. ADOS module 4 proves to be a reliable instrument with good predictive value. It…

  15. An accuracy evaluation of clinical, arthrometric, and stress-sonographic acute ankle instability examinations.

    PubMed

    Wiebking, Ulrich; Pacha, Tarek Omar; Jagodzinski, Michael

    2015-03-01

    Ankle sprain injuries, often due to lateral ligamentous injury, are the most common sports traumatology conditions. Correct diagnoses require an understanding of the assessment tools with a high degree of diagnostic accuracy. Obviously, there are still no clear consensuses or standard methods to differentiate between a ligament tear and an ankle sprain. In addition to clinical assessments, stress sonography, arthrometer and other methods are often performed simultaneously. These methods are often costly, however, and their accuracy is controversial. The aim of this study was to investigate three different measurement tools that can be used after a lateral ligament lesion of the ankle with injury of the anterior talofibular ligament to determine their diagnostic accuracy. Thirty patients were recruited for this study. The mean patient age was 35±14 years. There were 15 patients with a ligamentous rupture and 15 patients with an ankle sprain. We quantified two devices and one clinical assessment by which we calculated the sensitivity and specifity: Stress sonography according to Hoffmann, an arthrometer to investigate the 100N talar drawer and maximum manual testing and the clinical assessment of the anterior drawer test. A high resolution sonography was used as the gold standard. The ultrasound-assisted gadgetry according to Hoffmann, with a 3mm cut-off value, displayed a sensitivity of 0.27 and a specificity of 0.87. Using a 3.95mm cut-off value, the arthrometer displayed a sensitivity of 0.8 and a specificity of 0.4. The clinical investigation sensitivities and specificities were 0.93 and 0.67, respectively. Different assessment methods for ankle rupture diagnoses are suggested in the literature; however, these methods lack reliable data to set investigation standards. Clinical examination under adequate analgesia seems to remains the most reliable tool to investigate ligamentous ankle lesions. Further clinical studies with higher case numbers are necessary, however, to evaluate these findings and to measure the reliability. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  16. The alcohol use disorder and associated disabilities interview schedule-IV (AUDADIS-IV): reliability of new psychiatric diagnostic modules and risk factors in a general population sample.

    PubMed

    Ruan, W June; Goldstein, Risë B; Chou, S Patricia; Smith, Sharon M; Saha, Tulshi D; Pickering, Roger P; Dawson, Deborah A; Huang, Boji; Stinson, Frederick S; Grant, Bridget F

    2008-01-01

    This study presents test-retest reliability statistics and information on internal consistency for new diagnostic modules and risk factors for alcohol, drug, and psychiatric disorders from the Alcohol Use Disorder and Associated Disabilities Interview Schedule-IV (AUDADIS-IV). Test-retest statistics were derived from a random sample of 1899 adults selected from 34,653 respondents who participated in the 2004-2005 Wave 2 National Epidemiologic Survey on Alcohol and Related Conditions (NESARC). Internal consistency of continuous scales was assessed using the entire Wave 2 NESARC. Both test and retest interviews were conducted face-to-face. Test-retest and internal consistency results for diagnoses and symptom scales associated with posttraumatic stress disorder, attention-deficit/hyperactivity disorder, and borderline, narcissistic, and schizotypal personality disorders were predominantly good (kappa>0.63; ICC>0.69; alpha>0.75) and reliability for risk factor measures fell within the good to excellent range (intraclass correlations=0.50-0.94; alpha=0.64-0.90). The high degree of reliability found in this study suggests that new AUDADIS-IV diagnostic measures can be useful tools in research settings. The availability of highly reliable measures of risk factors for alcohol, drug, and psychiatric disorders will contribute to the validity of conclusions drawn from future research in the domains of substance use disorder and psychiatric epidemiology.

  17. Food allergy: opportunities and challenges in the clinical practice of allergy and immunology.

    PubMed

    James, John M

    2004-10-01

    Food allergy offers numerous opportunities and challenges for the allergy and clinical immunology specialist. Physicians with board certification in allergy and clinical immunology should be the main source of reliable clinical information to educate patients with food-related disorders. There has been a wealth of reliable information published related to food allergy that can be utilized by health care providers in clinical practice. This includes information about the cross-reactivity of food allergens, the evaluation of potential new therapies, and the practical application of new diagnostic methods and management strategies. This article addresses some of the new developments in food allergy, with an emphasis on cross-reactvity of food allergens, recombinant food allergens, and potential future therapies for food allergy.

  18. Comparison of diagnostic techniques for the detection of Cryptosporidium oocysts in animal samples

    PubMed Central

    Mirhashemi, Marzieh Ezzaty; Zintl, Annetta; Grant, Tim; Lucy, Frances E.; Mulcahy, Grace; De Waal, Theo

    2015-01-01

    While a large number of laboratory methods for the detection of Cryptosporidium oocysts in faecal samples are now available, their efficacy for identifying asymptomatic cases of cryptosporidiosis is poorly understood. This study was carried out to determine a reliable screening test for epidemiological studies in livestock. In addition, three molecular tests were compared to identify Cryptosporidium species responsible for the infection in cattle, sheep and horses. A variety of diagnostic tests including microscopic (Kinyoun's staining), immunological (Direct Fluorescence Antibody tests or DFAT), enzyme-linked immunosorbent assay (ELISA), and molecular methods (nested PCR) were compared to assess their ability to detect Cryptosporidium in cattle, horse and sheep faecal samples. The results indicate that the sensitivity and specificity of each test is highly dependent on the input samples; while Kinyoun's and DFAT proved to be reliable screening tools for cattle samples, DFAT and PCR analysis (targeted at the 18S rRNA gene fragment) were more sensitive for screening sheep and horse samples. Finally different PCR primer sets targeted at the same region resulted in the preferential amplification of certain Cryptosporidium species when multiple species were present in the sample. Therefore, for identification of Cryptosporidium spp. in the event of asymptomatic cryptosporidiosis, the combination of different 18S rRNA nested PCR primer sets is recommended for further epidemiological applications and also tracking the sources of infection. PMID:25662435

  19. Surface-Enhanced Raman Scattering-Based Immunoassay Technologies for Detection of Disease Biomarkers

    PubMed Central

    Smolsky, Joseph; Kaur, Sukhwinder; Hayashi, Chihiro; Batra, Surinder K.; Krasnoslobodtsev, Alexey V.

    2017-01-01

    Detection of biomarkers is of vital importance in disease detection, management, and monitoring of therapeutic efficacy. Extensive efforts have been devoted to the development of novel diagnostic methods that detect and quantify biomarkers with higher sensitivity and reliability, contributing to better disease diagnosis and prognosis. When it comes to such devastating diseases as cancer, these novel powerful methods allow for disease staging as well as detection of cancer at very early stages. Over the past decade, there have been some advances in the development of platforms for biomarker detection of diseases. The main focus has recently shifted to the development of simple and reliable diagnostic tests that are inexpensive, accurate, and can follow a patient’s disease progression and therapy response. The individualized approach in biomarker detection has been also emphasized with detection of multiple biomarkers in body fluids such as blood and urine. This review article covers the developments in Surface-Enhanced Raman Scattering (SERS) and related technologies with the primary focus on immunoassays. Limitations and advantages of the SERS-based immunoassay platform are discussed. The article thoroughly describes all components of the SERS immunoassay and highlights the superior capabilities of SERS readout strategy such as high sensitivity and simultaneous detection of a multitude of biomarkers. Finally, it introduces recently developed strategies for in vivo biomarker detection using SERS. PMID:28085088

  20. Neuroleptic-induced movement disorders in a naturalistic schizophrenia population: diagnostic value of actometric movement patterns

    PubMed Central

    Janno, Sven; Holi, Matti M; Tuisku, Katinka; Wahlbeck, Kristian

    2008-01-01

    Background Neuroleptic-induced movement disorders (NIMDs) have overlapping co-morbidity. Earlier studies have described typical clinical movement patterns for individual NIMDs. This study aimed to identify specific movement patterns for each individual NIMD using actometry. Methods A naturalistic population of 99 schizophrenia inpatients using conventional antipsychotics and clozapine was evaluated. Subjects with NIMDs were categorized using the criteria for NIMD found in the Diagnostic and Statistical Manual for Mental Disorders – Fourth Edition (DSM-IV). Two blinded raters evaluated the actometric-controlled rest activity data for activity periods, rhythmical activity, frequencies, and highest acceleration peaks. A simple subjective question was formulated to test patient-based evaluation of NIMD. Results The patterns of neuroleptic-induced akathisia (NIA) and pseudoakathisia (PsA) were identifiable in actometry with excellent inter-rater reliability. The answers to the subjective question about troubles with movements distinguished NIA patients from other patients rather well. Also actometry had rather good screening performances in distinguishing akathisia from other NIMD. Actometry was not able to reliably detect patterns of neuroleptic-induced parkinsonism and tardive dyskinesia. Conclusion The present study showed that pooled NIA and PsA patients had a different pattern in lower limb descriptive actometry than other patients in a non-selected sample. Careful questioning of patients is a useful method of diagnosing NIA in a clinical setting. PMID:18419829

  1. Facile Determination of Sodium Ion and Osmolarity in Artificial Tears by Sequential DNAzymes.

    PubMed

    Kim, Eun Hye; Lee, Eun-Song; Lee, Dong Yun; Kim, Young-Pil

    2017-12-07

    Despite high relevance of tear osmolarity and eye abnormality, numerous methods for detecting tear osmolarity rely upon expensive osmometers. We report a reliable method for simply determining sodium ion-based osmolarity in artificial tears using sequential DNAzymes. When sodium ion-specific DNAzyme and peroxidase-like DNAzyme were used as a sensing and detecting probe, respectively, the concentration of Na⁺ in artificial tears could be measured by absorbance or fluorescence intensity, which was highly correlated with osmolarity over the diagnostic range ( R ² > 0.98). Our approach is useful for studying eye diseases in relation to osmolarity.

  2. DSM-III field trials: I. Initial interrater diagnostic reliability.

    PubMed

    Spitzer, R L; Forman, J B; Nee, J

    1979-06-01

    The interrater agreement for major diagnostic categories in studies using DSM-I and DSM-II was usually only fair or poor. In phase one of the DSM-III field trials the overall kappa coefficient of agreement for axis I diagnoses of 281 adult patients was .78 for joint interviews and .66 for diagnoses made after separate interviews; for axis II--personality disorders and specific developmental disorders--the coefficients of agreement were .61 and .54. The interrater reliability of DSM--III is, in general, higher than that previously achieved and may be due to changes in the classification itself, the separation of axis I from axis II conditions, the systematic description of the various disorders, and the inclusion of diagnostic criteria.

  3. Feasibility and acceptability of the DSM-5 Field Trial procedures in the Johns Hopkins Community Psychiatry Programs.

    PubMed

    Clarke, Diana E; Wilcox, Holly C; Miller, Leslie; Cullen, Bernadette; Gerring, Joan; Greiner, Lisa H; Newcomer, Alison; McKitty, Mellisha V; Regier, Darrel A; Narrow, William E

    2014-06-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) contains criteria for psychiatric diagnoses that reflect advances in the science and conceptualization of mental disorders and address the needs of clinicians. DSM-5 also recommends research on dimensional measures of cross-cutting symptoms and diagnostic severity, which are expected to better capture patients' experiences with mental disorders. Prior to its May 2013 release, the American Psychiatric Association (APA) conducted field trials to examine the feasibility, clinical utility, reliability, and where possible, the validity of proposed DSM-5 diagnostic criteria and dimensional measures. The methods and measures proposed for the DSM-5 field trials were pilot tested in adult and child/adolescent clinical samples, with the goal to identify and correct design and procedural problems with the proposed methods before resources were expended for the larger DSM-5 Field Trials. Results allowed for the refinement of the protocols, procedures, and measures, which facilitated recruitment, implementation, and completion of the DSM-5 Field Trials. These results highlight the benefits of pilot studies in planning large multisite studies. Copyright © 2013, American Psychiatric Association. All rights reserved.

  4. Tooth-size discrepancy: A comparison between manual and digital methods

    PubMed Central

    Correia, Gabriele Dória Cabral; Habib, Fernando Antonio Lima; Vogel, Carlos Jorge

    2014-01-01

    Introduction Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. Objective This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. Material and Methods To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. Results Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05), except for values found by the linear digital method which revealed a slight, non-significant statistical difference. Conclusions Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable. PMID:25279529

  5. A Psychometric Study of the Bayley Scales of Infant and Toddler Development in Persian Language Children.

    PubMed

    Azari, Nadia; Soleimani, Farin; Vameghi, Roshanak; Sajedi, Firoozeh; Shahshahani, Soheila; Karimi, Hossein; Kraskian, Adis; Shahrokhi, Amin; Teymouri, Robab; Gharib, Masoud

    2017-01-01

    Bayley Scales of infant & toddler development is a well-known diagnostic developmental assessment tool for children aged 1-42 months. Our aim was investigating the validity & reliability of this scale in Persian speaking children. The method was descriptive-analytic. Translation- back translation and cultural adaptation was done. Content & face validity of translated scale was determined by experts' opinions. Overall, 403 children aged 1 to 42 months were recruited from health centers of Tehran, during years of 2013-2014 for developmental assessment in cognitive, communicative (receptive & expressive) and motor (fine & gross) domains. Reliability of scale was calculated through three methods; internal consistency using Cronbach's alpha coefficient, test-retest and interrater methods. Construct validity was calculated using factor analysis and comparison of the mean scores methods. Cultural and linguistic changes were made in items of all domains especially on communication subscale. Content and face validity of the test were approved by experts' opinions. Cronbach's alpha coefficient was above 0.74 in all domains. Pearson correlation coefficient in various domains, were ≥ 0.982 in test retest method, and ≥0.993 in inter-rater method. Construct validity of the test was approved by factor analysis. Moreover, the mean scores for the different age groups were compared and statistically significant differences were observed between mean scores of different age groups, that confirms validity of the test. The Bayley Scales of Infant and Toddler Development is a valid and reliable tool for child developmental assessment in Persian language children.

  6. Quantitative analysis of in situ optical diagnostics for inferring particle/aggregate parameters in flames: Implications for soot surface growth and total emissivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koeylue, U.O.

    1997-05-01

    An in situ particulate diagnostic/analysis technique is outlined based on the Rayleigh-Debye-Gans polydisperse fractal aggregate (RDG/PFA) scattering interpretation of absolute angular light scattering and extinction measurements. Using proper particle refractive index, the proposed data analysis method can quantitatively yield all aggregate parameters (particle volume fraction, f{sub v}, fractal dimension, D{sub f}, primary particle diameter, d{sub p}, particle number density, n{sub p}, and aggregate size distribution, pdf(N)) without any prior knowledge about the particle-laden environment. The present optical diagnostic/interpretation technique was applied to two different soot-containing laminar and turbulent ethylene/air nonpremixed flames in order to assess its reliability. The aggregate interpretationmore » of optical measurements yielded D{sub f}, d{sub p}, and pdf(N) that are in excellent agreement with ex situ thermophoretic sampling/transmission electron microscope (TS/TEM) observations within experimental uncertainties. However, volume-equivalent single particle models (Rayleigh/Mie) overestimated d{sub p} by about a factor of 3, causing an order of magnitude underestimation in n{sub p}. Consequently, soot surface areas and growth rates were in error by a factor of 3, emphasizing that aggregation effects need to be taken into account when using optical diagnostics for a reliable understanding of soot formation/evolution mechanism in flames. The results also indicated that total soot emissivities were generally underestimated using Rayleigh analysis (up to 50%), mainly due to the uncertainties in soot refractive indices at infrared wavelengths. This suggests that aggregate considerations may not be essential for reasonable radiation heat transfer predictions from luminous flames because of fortuitous error cancellation, resulting in typically a 10 to 30% net effect.« less

  7. 2007 Beyond SBIR Phase II: Bringing Technology Edge to the Warfighter

    DTIC Science & Technology

    2007-08-23

    Systems Trade-Off Analysis and Optimization Verification and Validation On-Board Diagnostics and Self - healing Security and Anti-Tampering Rapid...verification; Safety and reliability analysis of flight and mission critical systems On-Board Diagnostics and Self - Healing Model-based monitoring and... self - healing On-board diagnostics and self - healing ; Autonomic computing; Network intrusion detection and prevention Anti-Tampering and Trust

  8. Brief Report: Telephone Administration of the Autism Diagnostic Interview-Revised--Reliability and Suitability for Use in Research

    ERIC Educational Resources Information Center

    Ward-King, Jessica; Cohen, Ira L.; Penning, Henderika; Holden, Jeanette J. A.

    2010-01-01

    The Autism Diagnostic Interview-Revised is one of the "gold standard" diagnostic tools for autism spectrum disorders. It is traditionally administered face-to-face. Cost and geographical concerns constrain the employment of the ADI-R for large-scale research projects. The telephone interview is a reasonable alternative, but has not yet been…

  9. The Reliability and Validity of the Panic Disorder Self-Report: A New Diagnostic Screening Measure of Panic Disorder

    ERIC Educational Resources Information Center

    Newman, Michelle G.; Holmes, Marilyn; Zuellig, Andrea R.; Kachin, Kevin E.; Behar, Evelyn

    2006-01-01

    This study examined the Panic Disorder Self-Report (PDSR), a new self-report diagnostic measure of panic disorder based on the 4th edition of the Diagnostic and Statistical Manual of Mental Disorders (American Psychiatric Association, 1994). PDSR diagnoses were compared with structured interview diagnoses of individuals with generalized anxiety…

  10. Optical detection of metastatic cancer cells using a scanned laser pico-projection system

    NASA Astrophysics Data System (ADS)

    Huang, Chih-Ling; Chiu, Wen-Tai; Lo, Yu-Lung; Chuang, Chin-Ho; Chen, Yu-Bin; Chang, Shu-Jing; Ke, Tung-Ting; Cheng, Hung-Chi; Wu, Hua-Lin

    2015-03-01

    Metastasis is responsible for 90% of all cancer-related deaths in humans. As a result, reliable techniques for detecting metastatic cells are urgently required. Although various techniques have been proposed for metastasis detection, they are generally capable of detecting metastatic cells only once migration has already occurred. Accordingly, the present study proposes an optical method for physical characterization of metastatic cancer cells using a scanned laser pico-projection system (SLPP). The validity of the proposed method is demonstrated using five pairs of cancer cell lines and two pairs of non-cancer cell lines treated by IPTG induction in order to mimic normal cells with an overexpression of oncogene. The results show that for all of the considered cell lines, the SLPP speckle contrast of the high-metastatic cells is significantly higher than that of the low-metastatic cells. As a result, the speckle contrast measurement provides a reliable means of distinguishing quantitatively between low- and high-metastatic cells of the same origin. Compared to existing metastasis detection methods, the proposed SLPP approach has many advantages, including a higher throughput, a lower cost, a larger sample size and a more reliable diagnostic performance. As a result, it provides a highly promising solution for physical characterization of metastatic cancer cells in vitro.

  11. A study on the reproducibility of cephalometric landmarks when undertaking a three-dimensional (3D) cephalometric analysis

    PubMed Central

    Llamas, José M.; Cibrián, Rosa; Gandia, José L.; Paredes, Vanessa

    2012-01-01

    Objectives: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The first step must be to study the characteristics of these devices in terms of accuracy and reliability of the most commonly used landmarks. The aims were 1- To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2- To determine which of those landmarks are more vs. less reliable and 3- To introduce planes of reference so as to create cephalometric analyses appropriated to the 3D reality. Study design: Fifteen patients who had a CBCT (i-CAT®) as a diagnostic register were selected. To assess the reproducibility on landmark location and the differences in the measurements of two observers at different times, 41 landmarks were defined on the three spatial axes (X,Y,Z) and located. 3.690 measurements were taken and, as each determination has 3 coordinates, 11.070 data were processed with SPSS® statistical package. To discover the reproducibility of the method on landmark location, an ANOVA was undertaken using two variation factors: time (t1, t2 and t3) and observer (Ob1 and Ob2) for each axis (X, Y and Z) and landmark. The order of the CBCT scans submitted to the observers (Ob1, Ob2) at t1, t2, and t3, were different and randomly allocated. Multiple comparisons were undertaken using the Bonferroni test. The intra- and inter-examiner ICC´s were calculated. Results: Intra- and inter-examiner reliability was high, both being ICC ≥ 0.99, with the best frequency on axis Z. Conclusions: The most reliable landmarks were: Nasion, Sella, Basion, left Porion, point A, anterior nasal spine, Pogonion, Gnathion, Menton, frontozygomatic sutures, first lower molars and upper and lower incisors. Those with less reliability were the supraorbitals, right zygion and posterior nasal spine. Key words:Cone Beam Computed Tomography, cephalometry, landmark, orthodontics, reliability. PMID:22322503

  12. Methodology and technical requirements of the galectin-3 test for the preoperative characterization of thyroid nodules.

    PubMed

    Bartolazzi, Armando; Bellotti, Carlo; Sciacchitano, Salvatore

    2012-01-01

    In the last decade, the β-galactosyl binding protein galectin-3 has been the object of extensive molecular, structural, and functional studies aimed to clarify its biological role in cancer. Multicenter studies also contributed to discover the potential clinical value of galectin-3 expression analysis in distinguishing, preoperatively, benign from malignant thyroid nodules. As a consequence galectin-3 is receiving significant attention as tumor marker for thyroid cancer diagnosis, but some conflicting results mostly owing to methodological problems have been published. The possibility to apply preoperatively a reliable galectin-3 test method on fine needle aspiration biopsy (FNA)-derived thyroid cells represents an important achievement. When correctly applied, the method reduces consistently the gray area of thyroid FNA cytology, contributing to avoid unnecessary thyroid surgery. Although the efficacy and reliability of the galectin-3 test method have been extensively proved in several studies, its translation in the clinical setting requires well-standardized reagents and procedures. After a decade of experimental work on galectin-3-related basic and translational research projects, the major methodological problems that may potentially impair the diagnostic performance of galectin-3 immunotargeting are highlighted and discussed in detail. A standardized protocol for a reliable galectin-3 expression analysis is finally provided. The aim of this contribution is to improve the clinical management of patients with thyroid nodules, promoting the preoperative use of a reliable galectin-3 test method as ancillary technique to conventional thyroid FNA cytology. The final goal is to decrease unnecessary thyroid surgery and its related social costs.

  13. Raptor: A Portable Biosensor Upgraded for Reliability and Sensitivity

    DTIC Science & Technology

    2003-07-01

    Research Center for Molecular Diagnostics and Therapy. The F. tularensis antigen (killed vaccine strain), affinity-purified rabbit anti-B...Russian Research Center of Molecular Diagnostics and Therapies, for their generous donations materials. The views expressed here are those of the

  14. Concordance in diagnostic testing for respiratory pathogens of Bighorn Sheep

    USDA-ARS?s Scientific Manuscript database

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack ...

  15. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    PubMed

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  16. Improving utility of brain tumor confocal laser endomicroscopy: objective value assessment and diagnostic frame detection with convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Izadyyazdanabadi, Mohammadhassan; Belykh, Evgenii; Martirosyan, Nikolay; Eschbacher, Jennifer; Nakaji, Peter; Yang, Yezhou; Preul, Mark C.

    2017-03-01

    Confocal laser endomicroscopy (CLE), although capable of obtaining images at cellular resolution during surgery of brain tumors in real time, creates as many non-diagnostic as diagnostic images. Non-useful images are often distorted due to relative motion between probe and brain or blood artifacts. Many images, however, simply lack diagnostic features immediately informative to the physician. Examining all the hundreds or thousands of images from a single case to discriminate diagnostic images from nondiagnostic ones can be tedious. Providing a real time diagnostic value assessment of images (fast enough to be used during the surgical acquisition process and accurate enough for the pathologist to rely on) to automatically detect diagnostic frames would streamline the analysis of images and filter useful images for the pathologist/surgeon. We sought to automatically classify images as diagnostic or non-diagnostic. AlexNet, a deep-learning architecture, was used in a 4-fold cross validation manner. Our dataset includes 16,795 images (8572 nondiagnostic and 8223 diagnostic) from 74 CLE-aided brain tumor surgery patients. The ground truth for all the images is provided by the pathologist. Average model accuracy on test data was 91% overall (90.79 % accuracy, 90.94 % sensitivity and 90.87 % specificity). To evaluate the model reliability we also performed receiver operating characteristic (ROC) analysis yielding 0.958 average for area under ROC curve (AUC). These results demonstrate that a deeply trained AlexNet network can achieve a model that reliably and quickly recognizes diagnostic CLE images.

  17. Translated Versions of Voice Handicap Index (VHI)-30 across Languages: A Systematic Review

    PubMed Central

    SEIFPANAHI, Sadegh; JALAIE, Shohreh; NIKOO, Mohammad Reza; SOBHANI-RAD, Davood

    2015-01-01

    Background: In this systematic review, the aim is to investigate different VHI-30 versions between languages regarding their validity, reliability and their translation process. Methods: Articles were extracted systematically from some of the prime databases including Cochrane, googlescholar, MEDLINE (via PubMed gate), Sciencedirect, Web of science, and their reference lists by Voice Handicap Index keyword with only title limitation and time of publication (from 1997 to 2014). However the other limitations (e.g. excluding non-English, other versions of VHI ones, and so on) applied manually after studying the papers. In order to appraise the methodology of the papers, three authors did it by 12-item diagnostic test checklist in “Critical Appraisal Skills Programme” or (CASP) site. After applying all of the screenings, the papers that had the study eligibility criteria such as; translation, validity, and reliability processes, included in this review. Results: The remained non-repeated articles were 12 from different languages. All of them reported validity, reliability and translation method, which presented in details in this review. Conclusion: Mainly the preferred method for translation in the gathered papers was “Brislin’s classic back-translation model (1970), although the procedure was not performed completely but it was more prominent than other translation procedures. High test-retest reliability, internal consistency and moderate construct validity between different languages in regards to all 3 VHI-30 domains confirm the applicability of translated VHI-30 version across languages. PMID:26056664

  18. Reliability evaluation of oil pipelines operating in aggressive environment

    NASA Astrophysics Data System (ADS)

    Magomedov, R. M.; Paizulaev, M. M.; Gebel, E. S.

    2017-08-01

    In connection with modern increased requirements for ecology and safety, the development of diagnostic services complex is obligatory and necessary enabling to ensure the reliable operation of the gas transportation infrastructure. Estimation of oil pipelines technical condition should be carried out not only to establish the current values of the equipment technological parameters in operation, but also to predict the dynamics of changes in the physical and mechanical characteristics of the material, the appearance of defects, etc. to ensure reliable and safe operation. In the paper, existing Russian and foreign methods for evaluation of the oil pipelines reliability are considered, taking into account one of the main factors leading to the appearance of crevice in the pipeline material, i.e. change the shape of its cross-section, - corrosion. Without compromising the generality of the reasoning, the assumption of uniform corrosion wear for the initial rectangular cross section has been made. As a result a formula for calculation the probability of failure-free operation was formulated. The proposed mathematical model makes it possible to predict emergency situations, as well as to determine optimal operating conditions for oil pipelines.

  19. CT-guided robotically-assisted infiltration of foot and ankle joints.

    PubMed

    Wiewiorski, Martin; Valderrabano, Victor; Kretzschmar, Martin; Rasch, Helmut; Markus, Tanja; Dziergwa, Severine; Kos, Sebastian; Bilecen, Deniz; Jacob, Augustinus Ludwig

    2009-01-01

    It was our aim to describe a CT-guided robotically-assisted infiltration technique for diagnostic injections in foot and ankle orthopaedics. CT-guided mechatronically-assisted joint infiltration was performed on 16 patients referred to the orthopaedic department for diagnostic foot and ankle assessment. All interventions were performed using an INNOMOTION-assistance device on a multislice CT scanner in an image-guided therapy suite. Successful infiltration was defined as CT localization of contrast media in the target joint. Additionally, pre- and post-interventional VAS pain scores were assessed. All injections (16/16 joints) were technically successful. Contrast media deposit was documented in all targeted joints. Significant relief of pain was noted by all 16 patients (p<0.01). CT-guided robotically-assisted intervention is an exact, reliable and safe application method for diagnostic infiltration of midfoot and hindfoot joints. The high accuracy and feasibility in a clinical environment make it a viable alternative to the commonly used fluoroscopic-guided procedures.

  20. Noninvasive Brain Stimulation in Pediatric Attention-Deficit Hyperactivity Disorder (ADHD): A Review.

    PubMed

    Rubio, Belen; Boes, Aaron D; Laganiere, Simon; Rotenberg, Alexander; Jeurissen, Danique; Pascual-Leone, Alvaro

    2016-05-01

    Attention-deficit hyperactivity disorder (ADHD) is one of the most prevalent neurodevelopmental disorders in the pediatric population. The clinical management of ADHD is currently limited by a lack of reliable diagnostic biomarkers and inadequate therapy for a minority of patients who do not respond to standard pharmacotherapy. There is optimism that noninvasive brain stimulation may help to address these limitations. Transcranial magnetic stimulation and transcranial direct current stimulation are 2 methods of noninvasive brain stimulation that modulate cortical excitability and brain network activity. Transcranial magnetic stimulation can be used diagnostically to probe cortical neurophysiology, whereas daily use of repetitive transcranial magnetic stimulation or transcranial direct current stimulation can induce long-lasting and potentially therapeutic changes in targeted networks. In this review, we highlight research showing the potential diagnostic and therapeutic applications of transcranial magnetic stimulation and transcranial direct current stimulation in pediatric ADHD. We also discuss the safety and ethics of using these tools in the pediatric population. © The Author(s) 2015.

  1. VIRUS ISOLATION AND MOLECULAR DETECTION OF BLUETONGUE AND EPIZOOTIC HEMORRHAGIC DISEASE VIRUSES FROM NATURALLY INFECTED WHITE-TAILED DEER (ODOCOILEUS VIRGINIANUS).

    PubMed

    Kienzle, Clara; Poulson, Rebecca L; Ruder, Mark G; Stallknecht, David E

    2017-10-01

    Hemorrhagic disease in North America is caused by multiple serotypes of epizootic hemorrhagic disease virus (EHDV) and bluetongue virus (BTV). Diagnostic tests for detection of EHDV and BTV include virus isolation (VI), reverse transcriptase (RT)-PCR, and real-time RT-PCR (rRT-PCR). Our objective was to compare the diagnostic capabilities of three rRT-PCR protocols for detection of EHDV and BTV from naturally infected white-tailed deer (Odocoileus virginianus). We compared the effectiveness of these assays to traditional viral detection methods (e.g., VI) for historic and current clinical cases. Because of the variable nature of tissue collection and storage before diagnostic testing, an evaluation of viral persistence on multiple freeze-thaw events was also conducted. Two of the rRT-PCR assays provided for reliable detection of EHDV and BTV from 100% of clinically affected and VI-confirmed infected animals. Additionally, no significant change in viral titer was observed on multiple freeze-thaw events.

  2. New Thomson scattering diagnostic on RFX-mod.

    PubMed

    Alfier, A; Pasqualotto, R

    2007-01-01

    This article describes the completely renovated Thomson scattering (TS) diagnostic employed in the modified Reversed Field eXperiment (RFX-mod) since it restarted operation in 2005. The system measures plasma electron temperature and density profiles along an equatorial diameter, measuring in 84 positions with 7 mm spatial resolution. The custom built Nd:YLF laser produces a burst of 10 pulses at 50 Hz with energy of 3 J, providing ten profile measurements in a plasma discharge of about 300 ms duration. An optical delay system accommodates three scattering volumes in each of the 28 interference filter spectrometers. Avalanche photodiodes detect the Thomson scattering signals and allow them to be recorded by means of waveform digitizers. Electron temperature is obtained using an alternative relative calibration method, based on the use of a supercontinuum light source. Rotational Raman scattering in nitrogen has supplied the absolute calibration for the electron density measurements. During RFX-mod experimental campaigns in 2005, the TS diagnostic has demonstrated its performance, routinely providing reliable high resolution profiles.

  3. Optical biopsy of head and neck cancer using hyperspectral imaging and convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Halicek, Martin; Little, James V.; Wang, Xu; Patel, Mihir; Griffith, Christopher C.; El-Deiry, Mark W.; Chen, Amy Y.; Fei, Baowei

    2018-02-01

    Successful outcomes of surgical cancer resection necessitate negative, cancer-free surgical margins. Currently, tissue samples are sent to pathology for diagnostic confirmation. Hyperspectral imaging (HSI) is an emerging, non-contact optical imaging technique. A reliable optical method could serve to diagnose and biopsy specimens in real-time. Using convolutional neural networks (CNNs) as a tissue classifier, we developed a method to use HSI to perform an optical biopsy of ex-vivo surgical specimens, collected from 21 patients undergoing surgical cancer resection. Training and testing on samples from different patients, the CNN can distinguish squamous cell carcinoma (SCCa) from normal aerodigestive tract tissues with an area under the curve (AUC) of 0.82, 81% accuracy, 81% sensitivity, and 80% specificity. Additionally, normal oral tissues can be sub-classified into epithelium, muscle, and glandular mucosa using a decision tree method, with an average AUC of 0.94, 90% accuracy, 93% sensitivity, and 89% specificity. After separately training on thyroid tissue, the CNN differentiates between thyroid carcinoma and normal thyroid with an AUC of 0.95, 92% accuracy, 92% sensitivity, and 92% specificity. Moreover, the CNN can discriminate medullary thyroid carcinoma from benign multi-nodular goiter (MNG) with an AUC of 0.93, 87% accuracy, 88% sensitivity, and 85% specificity. Classical-type papillary thyroid carcinoma is differentiated from benign MNG with an AUC of 0.91, 86% accuracy, 86% sensitivity, and 86% specificity. Our preliminary results demonstrate that an HSI-based optical biopsy method using CNNs can provide multi-category diagnostic information for normal head-and-neck tissue, SCCa, and thyroid carcinomas. More patient data are needed in order to fully investigate the proposed technique to establish reliability and generalizability of the work.

  4. Systematic Review of the Diagnostic Accuracy and Therapeutic Effectiveness of Sacroiliac Joint Interventions.

    PubMed

    Simopoulos, Thomas T; Manchikanti, Laxmaiah; Gupta, Sanjeeva; Aydin, Steve M; Kim, Chong Hwan; Solanki, Daneshvari; Nampiaparampil, Devi E; Singh, Vijay; Staats, Peter S; Hirsch, Joshua A

    2015-01-01

    The sacroiliac joint is well known as a cause of low back and lower extremity pain. Prevalence estimates are 10% to 25% in patients with persistent axial low back pain without disc herniation, discogenic pain, or radiculitis based on multiple diagnostic studies and systematic reviews. However, at present there are no definitive management options for treating sacroiliac joint pain. To evaluate the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. A systematic review of the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. The available literature on diagnostic and therapeutic sacroiliac joint interventions was reviewed. The quality assessment criteria utilized were the Quality Appraisal of Reliability Studies (QAREL) checklist for diagnostic accuracy studies, Cochrane review criteria to assess sources of risk of bias, and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment (IPM-QRB) criteria for randomized therapeutic trials and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment for Nonrandomized Studies (IPM-QRBNR) for observational therapeutic assessments. The level of evidence was based on a best evidence synthesis with modified grading of qualitative evidence from Level I to Level V. Data sources included relevant literature published from 1966 through March 2015 that were identified through searches of PubMed and EMBASE, manual searches of the bibliographies of known primary and review articles, and all other sources. For the diagnostic accuracy assessment, and for the therapeutic modalities, the primary outcome measure of pain relief and improvement in functional status were utilized. A total of 11 diagnostic accuracy studies and 14 therapeutic studies were included. The evidence for diagnostic accuracy is Level II for dual diagnostic blocks with at least 70% pain relief as the criterion standard and Level III evidence for single diagnostic blocks with at least 75% pain relief as the criterion standard. The evidence for cooled radiofrequency neurotomy in managing sacroiliac joint pain is Level II to III. The evidence for conventional radiofrequency neurotomy, intraarticular steroid injections, and periarticular injections with steroids or botulinum toxin is limited: Level III or IV. The limitations of this systematic review include inconsistencies in diagnostic accuracy studies with a paucity of high quality, replicative, and consistent literature. The limitations for therapeutic interventions include variations in technique, variable diagnostic standards for inclusion criteria, and variable results. The evidence for the accuracy of diagnostic and therapeutic effectiveness of sacroiliac joint interventions varied from Level II to Level IV.

  5. WHAT ARE THE Omh {sup 2} ( z {sub 1}, z {sub 2}) AND Om ( z {sub 1}, z {sub 2}) DIAGNOSTICS TELLING US IN LIGHT OF H ( z ) DATA?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Xiaogang; Ding, Xuheng; Biesiada, Marek

    2016-07-01

    The two-point diagnostics Om ( z {sub i} , z {sub j} ) and Omh {sup 2}( z {sub i} , z {sub j} ) have been introduced as an interesting tool for testing the validity of the Λ cold dark matter (ΛCDM) model. Recently, Sahni et al. combined two independent measurements of H ( z ) from baryon acoustic oscillation (BAO) data with the value of the Hubble constant H {sub 0}, and used the second of these diagnostics to test the ΛCDM (a constant equation-of-state parameter for dark energy) model. Their result indicated a considerable tension between observationsmore » and predictions of the ΛCDM model. Since reliable data concerning the expansion rates of the universe at different redshifts H ( z ) are crucial for the successful application of this method, we investigate both two-point diagnostics on the most comprehensive set of N = 36 measurements of H ( z ) from BAOs and the differential ages (DAs) of passively evolving galaxies. We discuss the uncertainties of the two-point diagnostics and find that they are strongly non-Gaussian and follow the patterns deeply rooted in their very construction. Therefore we propose that non-parametric median statistics is the most appropriate way of treating this problem. Our results support the claims that ΛCDM is in tension with H ( z ) data according to the two-point diagnostics developed by Shafieloo, Sahni, and Starobinsky. However, other alternatives to the ΛCDM model, such as the wCDM or Chevalier–Polarski–Linder models, perform even worse. We also note that there are serious systematic differences between the BAO and DA methods that ought to be better understood before H ( z ) measurements can compete with other probes methods.« less

  6. ULTRASONOGRAPHY, AN EFFECTIVE TOOL IN DIAGNOSING PLANTAR FASCIITIS: A SYSTEMATIC REVIEW OF DIAGNOSTIC TRIALS

    PubMed Central

    Wyland, Matthew; Applequist, Lee; Bolowsky, Erin; Klingensmith, Heather; Virag, Isaac

    2016-01-01

    Background Plantar fasciitis (PF) is the most common cause of heel pain that affects 10% of the general population, whether living an athletic or sedentary lifestyle. The most frequent mechanism of injury is an inflammatory response that is caused by repetitive micro trauma. Many techniques are available to diagnose PF, including the use of ultrasonography (US). Purpose The purpose of this study is to systematically review and appraise previously published articles published between the years 2000 and 2015 that evaluated the effectiveness of using US in the process of diagnosing PF, as compared to alternative diagnostic methods. Methods A total of eight databases were searched to systematically review scholarly (peer reviewed) diagnostic and intervention articles pertaining to the ability of US to diagnose PF. Results Using specific key words the preliminary search yielded 264 articles, 10 of which were deemed relevant for inclusion in the study. Two raters independently scored each article using the 15 point modified QUADAS scale. Discussion Six studies compared the diagnostic efficacy of US to another diagnostic technique to diagnose PF, and four studies focused on comparing baseline assessment of plantar fascia before subsequent intervention. The most notable US outcomes measured were plantar fascia thickness, enthesopathy, and hypoechogenicity. Conclusion US was found to be accurate and reliable compared to alternative reference standards like MRI in the diagnosis of PF. The general advantages of US (e.g. cost efficient, ease of administration, non-invasive, limited contraindications) make it a superior diagnostic modality in the diagnosis of PF. US should be considered in rehabilitation clinics to effectively diagnose PF and to accurately monitor improvement in the disease process following rehabilitation interventions. Level of Evidence 1A PMID:27757279

  7. FDG-PET/CT for treatment response assessment in head and neck squamous cell carcinoma: a systematic review and meta-analysis of diagnostic performance.

    PubMed

    Helsen, Nils; Van den Wyngaert, Tim; Carp, Laurens; Stroobants, Sigrid

    2018-06-01

    18-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) is increasingly used to evaluate treatment response in head and neck squamous cell carcinoma (HNSCC). This analysis assessed the diagnostic value of FDG-PET/CT in detecting nodal disease within 6 months after treatment, considering patient and disease characteristics. A systematic review was performed using the MEDLINE and Web of Knowledge databases. The results were pooled using a bivariate random effects model of the sensitivity and specificity. Out of 22 identified studies, a meta-analysis of 20 studies (1293 patients) was performed. The pooled estimates of sensitivity, specificity and diagnostic odds ratio (with 95% CI) were 85% (76-91%), 93% (89-96%) and 76 (35-165), respectively. With the prevalence set at 10%, the positive and negative predictive values were 58% and 98%. There was significant heterogeneity between the trials (p < 0.001). HPV positive tumors were associated with lower sensitivity (75% vs 89%; p = 0.01) and specificity (87% vs 95%; p < 0.005). FDG-PET/CT within 6 months after (chemo)radiotherapy in HNSCC patients is a reliable method for ruling out residual/recurrent nodal disease and obviates the need for therapeutic intervention. However, FDG-PET/CT may be less reliable in HPV positive tumors and the optimal surveillance strategy remains to be determined.

  8. Establishing high resolution melting analysis: method validation and evaluation for c-RET proto-oncogene mutation screening.

    PubMed

    Benej, Martin; Bendlova, Bela; Vaclavikova, Eliska; Poturnajova, Martina

    2011-10-06

    Reliable and effective primary screening of mutation carriers is the key condition for common diagnostic use. The objective of this study is to validate the method high resolution melting (HRM) analysis for routine primary mutation screening and accomplish its optimization, evaluation and validation. Due to their heterozygous nature, germline point mutations of c-RET proto-oncogene, associated to multiple endocrine neoplasia type 2 (MEN2), are suitable for HRM analysis. Early identification of mutation carriers has a major impact on patients' survival due to early onset of medullary thyroid carcinoma (MTC) and resistance to conventional therapy. The authors performed a series of validation assays according to International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines for validation of analytical procedures, along with appropriate design and optimization experiments. After validated evaluation of HRM, the method was utilized for primary screening of 28 pathogenic c-RET mutations distributed among nine exons of c-RET gene. Validation experiments confirm the repeatability, robustness, accuracy and reproducibility of HRM. All c-RET gene pathogenic variants were detected with no occurrence of false-positive/false-negative results. The data provide basic information about design, establishment and validation of HRM for primary screening of genetic variants in order to distinguish heterozygous point mutation carriers among the wild-type sequence carriers. HRM analysis is a powerful and reliable tool for rapid and cost-effective primary screening, e.g., of c-RET gene germline and/or sporadic mutations and can be used as a first line potential diagnostic tool.

  9. Reliability and validity of the German version of the Structured Interview of Personality Organization (STIPO)

    PubMed Central

    2013-01-01

    Background The assessment of personality organization and its observable behavioral manifestations, i.e. personality functioning, has a long tradition in psychodynamic psychiatry. Recently, the DSM-5 Levels of Personality Functioning Scale has moved it into the focus of psychiatric diagnostics. Based on Kernberg’s concept of personality organization the Structured Interview of Personality Organization (STIPO) was developed for diagnosing personality functioning. The STIPO covers seven dimensions: (1) identity, (2) object relations, (3) primitive defenses, (4) coping/rigidity, (5) aggression, (6) moral values, and (7) reality testing and perceptual distortions. The English version of the STIPO has previously revealed satisfying psychometric properties. Methods Validity and reliability of the German version of the 100-item instrument have been evaluated in 122 psychiatric patients. All patients were diagnosed according to the Diagnostic and Statistical Manual for Mental Disorders (DSM-IV) and were assessed by means of the STIPO. Moreover, all patients completed eight questionnaires that served as criteria for external validity of the STIPO. Results Interrater reliability varied between intraclass correlations of .89 and 1.0, Crohnbach’s α for the seven dimensions was .69 to .93. All a priori selected questionnaire scales correlated significantly with the corresponding STIPO dimensions. Patients with personality disorder (PD) revealed significantly higher STIPO scores (i.e. worse personality functioning) than patients without PD; patients cluster B PD showed significantly higher STIPO scores than patients with cluster C PD. Conclusions Interrater reliability, Crohnbach’s α, concurrent validity, and differential validity of the STIPO are satisfying. The STIPO represents an appropriate instrument for the assessment of personality functioning in clinical and research settings. PMID:23941404

  10. Antisocial Personality Disorder Subscale (Chinese Version) of the Structured Clinical Interview for the DSM-IV Axis II disorders: validation study in Cantonese-speaking Hong Kong Chinese.

    PubMed

    Tang, D Y Y; Liu, A C Y; Leung, M H T; Siu, B W M

    2013-06-01

    OBJECTIVE. Antisocial personality disorder (ASPD) is a risk factor for violence and is associated with poor treatment response when it is a co-morbid condition with substance abuse. It is an under-recognised clinical entity in the local Hong Kong setting, for which there are only a few available Chinese-language diagnostic instruments. None has been tested for its psychometric properties in the Cantonese-speaking population in Hong Kong. This study therefore aimed to assess the reliability and validity of the Chinese version of the ASPD subscale of the Structured Clinical Interview for the DSM-IV Axis II Disorders (SCID-II) in Hong Kong Chinese. METHODS. This assessment tool was modified according to dialectal differences between Mainland China and Hong Kong. Inpatients in Castle Peak Hospital, Hong Kong, who were designated for priority follow-up based on their assessed propensity for violence and who fulfilled the inclusion criteria for the study, were recruited. To assess the level of agreement, best-estimate diagnosis made by a multidisciplinary team was compared with diagnostic status determined by the SCID-II ASPD subscale. The internal consistency, sensitivity, and specificity of the subscale were also calculated. RESULTS. The internal consistency of the subscale was acceptable at 0.79, whereas the test-retest reliability and inter-rater reliability showed an excellent and good agreement of 0.90 and 0.86, respectively. Best-estimate clinical diagnosis-SCID diagnosis agreement was acceptable at 0.76. The sensitivity, specificity, positive and negative predictive values were 0.91, 0.86, 0.83, and 0.93, respectively. CONCLUSION. The Chinese version of the SCID-II ASPD subscale is reliable and valid for diagnosing ASPD in a Cantonese-speaking clinical population.

  11. Test-Retest Reliability of the Multiple Sleep Latency Test in Narcolepsy without Cataplexy and Idiopathic Hypersomnia

    PubMed Central

    Trotti, Lynn Marie; Staab, Beth A.; Rye, David B.

    2013-01-01

    Study Objectives: Differentiation of narcolepsy without cataplexy from idiopathic hypersomnia relies entirely upon the multiple sleep latency test (MSLT). However, the test-retest reliability for these central nervous system hypersomnias has never been determined. Methods: Patients with narcolepsy without cataplexy, idiopathic hypersomnia, and physiologic hypersomnia who underwent two diagnostic multiple sleep latency tests were identified retrospectively. Correlations between the mean sleep latencies on the two studies were evaluated, and we probed for demographic and clinical features associated with reproducibility versus change in diagnosis. Results: Thirty-six patients (58% women, mean age 34 years) were included. Inter -test interval was 4.2 ± 3.8 years (range 2.5 months to 16.9 years). Mean sleep latencies on the first and second tests were 5.5 (± 3.7 SD) and 7.3 (± 3.9) minutes, respectively, with no significant correlation (r = 0.17, p = 0.31). A change in diagnosis occurred in 53% of patients, and was accounted for by a difference in the mean sleep latency (N = 15, 42%) or the number of sleep onset REM periods (N = 11, 31%). The only feature predictive of a diagnosis change was a history of hypnagogic or hypnopompic hallucinations. Conclusions: The multiple sleep latency test demonstrates poor test-retest reliability in a clinical population of patients with central nervous system hypersomnia evaluated in a tertiary referral center. Alternative diagnostic tools are needed. Citation: Trotti LM; Staab BA; Rye DB. Test- retest reliability of the multiple sleep latency test in narcolepsy without cataplexy and idiopathic hypersomnia. J Clin Sleep Med 2013;9(8):789-795. PMID:23946709

  12. Validity and Reliability of Clinical Examination in the Diagnosis of Myofascial Pain Syndrome and Myofascial Trigger Points in Upper Quarter Muscles.

    PubMed

    Mayoral Del Moral, Orlando; Torres Lacomba, María; Russell, I Jon; Sánchez Méndez, Óscar; Sánchez Sánchez, Beatriz

    2017-12-15

    To determine whether two independent examiners can agree on a diagnosis of myofascial pain syndrome (MPS). To evaluate interexaminer reliability in identifying myofascial trigger points in upper quarter muscles. To evaluate the reliability of clinical diagnostic criteria for the diagnosis of MPS. To evaluate the validity of clinical diagnostic criteria for the diagnosis of MPS. Validity and reliability study. Provincial Hospital. Toledo, Spain. Twenty myofascial pain syndrome patients and 20 healthy, normal control subjects, enrolled by a trained and experienced examiner. Ten bilateral muscles from the upper quarter were evaluated by two experienced examiners. The second examiner was blinded to the diagnosis group. The MPS diagnosis required at least one muscle to have an active myofascial trigger point. Three to four days separated the two examinations. The primary outcome measure was the frequency with which the two examiners agreed on the classification of the subjects as patients or as healthy controls. The kappa statistic (K) was used to determine the level of agreement between both examinations, interpreted as very good (0.81-1.00), good (0.61-0.80), moderate (0.41-0.60), fair (0.21-0.40), or poor (≤0.20). Interexaminer reliability for identifying subjects with MPS was very good (K = 1.0). Interexaminer reliability for identifying muscles leading to a diagnosis of MPS was also very good (K = 0.81). Sensitivity and specificity showed high values for most examination tests in all muscles, which confirms the validity of clinical diagnostic criteria in the diagnosis of MPS. Interrater reliability between two expert examiners identifying subjects with MPS involving upper quarter muscles exhibited substantial agreement. These results suggest that clinical criteria can be valid and reliable in the diagnosis of this condition. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  13. The Alcohol Use Disorder and Associated Disabilities Interview Schedule-IV (AUDADIS-IV): Reliability of New Psychiatric Diagnostic Modules and Risk Factors in a General Population Sample

    PubMed Central

    Ruan, W. June; Goldstein, Risë B.; Chou, S. Patricia; Smith, Sharon M.; Saha, Tulshi D.; Pickering, Roger P.; Dawson, Deborah A.; Huang, Boji; Stinson, Frederick S.; Grant, Bridget F.

    2008-01-01

    This study presents test-retest reliability statistics and information on internal consistency for new diagnostic modules and risk factor of alcohol, drug, and psychiatric disorders the Alcohol Use Disorder and Associated Disabilities Interview Schedule-IV (AUDADIS-IV). Test-retest statistics were derived from a random sample of 1,899 adults selected from 34,653 respondents who participated in the 2004–2005 Wave 2 National Epidemiologic Survey on Alcohol and Related Conditions (NESARC). Internal consistency of continuous scales was assessed using the entire Wave 2 NESARC. Both test and retest interviews were conducted face-to-face. Test-retest and internal consistency results for diagnoses and symptom scales associated with posttraumatic stress disorder, attention-deficit/hyperactivity disorder, and borderline, narcissistic, and schizotypal personality disorders were predominantly good (kappa > 0.63; ICC > 0.69; alpha > 0.75) and reliability for risk factor measures fell within the good to excellent range (intraclass correlations = 0.50–0.94; alpha = 0.64–0.90). The high degree of reliability found in this study suggests that new AUDADIS-IV diagnostic measures can be useful tools in research settings. The availability of highly reliable measures of risk factors of alcohol, drug, and psychiatric disorders will contribute to the validity of conclusions drawn from future research in the domains of substance use disorder and psychiatric epidemiology. PMID:17706375

  14. Competency-based assessment in surgeon-performed head and neck ultrasonography: A validity study.

    PubMed

    Todsen, Tobias; Melchiors, Jacob; Charabi, Birgitte; Henriksen, Birthe; Ringsted, Charlotte; Konge, Lars; von Buchwald, Christian

    2018-06-01

    Head and neck ultrasonography (HNUS) increasingly is used as a point-of-care diagnostic tool by otolaryngologists. However, ultrasonography (US) is a very operator-dependent image modality. Hence, this study aimed to explore the diagnostic accuracy of surgeon-performed HNUS and to establish validity evidence for an objective structured assessment of ultrasound skills (OSAUS) used for competency-based assessment. A prospective experimental study. Six otolaryngologists and 11 US novices were included in a standardized test setup for which they had to perform focused HNUS of eight patients suspected for different head and neck lesions. Their diagnostic accuracy was calculated based on the US reports, and two blinded raters assessed the video-recorded US performance using the OSAUS scale. The otolaryngologists obtained a high diagnostic accuracy on 88% (range 63%-100%) compared to the US novices on 38% (range 0-63%); P < 0.001. The OSAUS score demonstrated good inter-case reliability (0.85) and inter-rater reliability (0.76), and significant discrimination between otolaryngologist and US novices; P < 0.001. A strong correlation between the OSAUS score and the diagnostic accuracy was found (Spearman's ρ, 0.85; P < P 0.001), and a pass/fail score was established at 2.8. Strong validity evidence supported the use of the OSAUS scale to assess HNUS competence with good reliability, significant discrimination between US competence levels, and a strong correlation of assessment score to diagnostic accuracy. An OSAUS pass/fail score was established and could be used for competence-based assessment in surgeon-performed HNUS. NA. Laryngoscope, 128:1346-1352, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Attitudes and beliefs toward the use of a dental diagnostic terminology A survey of dental providers in a dental practice

    PubMed Central

    Ramoni, Rachel B.; Walji, Muhammad F.; Kim, Soyun; Tokede, Oluwabunmi; McClellan, Lyle; Simmons, Kristen; Skourtes, Eugene; Yansane, Alfa; White, Joel M.; Kalenderian, Elsbeth

    2015-01-01

    Background Attitudes and views are critical to the adoption of innovation. While there have been broadening calls for a standardized dental diagnostic terminology, little is known about the views of private practice dental team members towards the adoption of such a terminology. Methods A survey was developed using validated questions identified through literature review. Domain experts’ input allowed for further modifications. The final survey was administered electronically to 814 team members at a multi-office practice based in the Pacific Northwest. Results Response proportion was 92%. The survey had excellent reliability (Cronbach alpha coefficient = 0.87). Results suggested that participants showed, in general, positive attitudes and beliefs towards using a standardized diagnostic terminology in their practices. Additional written comments by participants highlighted the potential for improved communication with use of the terminology. Conclusions Dental providers and staff in one multi-office practice showed positive attitudes towards the use of a diagnostic terminology, specifically they believed it would improve communication between the dentist and patient as well as among providers, while expressing some concerns if using standardized dental diagnostic terms helps clinicians to deliver better dental care. Practical Implications As the dental profession is advancing towards the use of standardized diagnostic terminologies, successful implementation will require that dental team leaders prepare their dental teams by gauging their attitude toward the use of such a terminology. PMID:26025826

  16. Automated System of Diagnostic Monitoring at Bureya HPP Hydraulic Engineering Installations: a New Level of Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musyurka, A. V., E-mail: musyurkaav@burges.rushydro.ru

    This article presents the design, hardware, and software solutions developed and placed in service for the automated system of diagnostic monitoring (ASDM) for hydraulic engineering installations at the Bureya HPP, and assuring a reliable process for monitoring hydraulic engineering installations. Project implementation represents a timely solution of problems addressed by the hydraulic engineering installation diagnostics section.

  17. Reliability of Use, Abuse, and Dependence of Four Types of Inhalants in Adolescents and Young Adults

    PubMed Central

    Ridenour, Ty A.; Bray, Bethany C.; Cottler, Linda B.

    2007-01-01

    Inhalants, as a class of drugs, consists of heterogeneous substances that include some of the most dangerous drugs on a per use basis. Research on inhalant abuse has lagged behind other drugs partly because of the need for a diagnostic instrument of different types of inhalants. This study was conducted to obtain reliability estimates for the new Substance Abuse Module DSM-IV inhalants diagnoses for four types of inhalants: aerosols, gases, nitrites, and solvents as well as different diagnostic configurations of inhalant use. Participants were 162 community sample adolescents or young adults (mean age = 20.3 years, SD = 2.4). Two-thirds of the sample was male and 83.3% was Caucasian. Kappas and intraclass correlation coefficients were computed to estimate test-retest reliabilities. Results suggested (a) abuse was more common than dependence (34.6% vs. 12.3%), (b) reliabilities of abuse criteria and diagnosis were good to excellent across subtypes, and (c) reliabilities of dependence criteria and diagnoses were poor to good across subtypes. Alternative configurations of DSM-IV criteria that were consistent with previous research on adolescents provided excellent reliabilities across subtypes of inhalants. Moreover, 11.1% of participants experienced inhalants withdrawal. PMID:17576041

  18. Automatic detection of oesophageal intubation based on ventilation pressure waveforms shows high sensitivity and specificity in patients with pulmonary disease.

    PubMed

    Kalmar, Alain F; Absalom, Anthony; Rombouts, Pieter; Roets, Jelle; Dewaele, Frank; Verdonck, Pascal; Stemerdink, Arjanne; Zijlstra, Jan G; Monsieurs, Koenraad G

    2016-08-01

    Unrecognised endotracheal tube misplacement in emergency intubations has a reported incidence of up to 17%. Current detection methods have many limitations restricting their reliability and availability in these circumstances. There is therefore a clinical need for a device that is small enough to be practical in emergency situations and that can detect oesophageal intubation within seconds. In a first reported evaluation, we demonstrated an algorithm based on pressure waveform analysis, able to determine tube location with high reliability in healthy patients. The aim of this study was to validate the specificity of the algorithm in patients with abnormal pulmonary compliance, and to demonstrate the reliability of a newly developed small device that incorporates the technology. Intubated patients with mild to moderate lung injury, admitted to intensive care were included in the study. The device was connected to the endotracheal tube, and three test ventilations were performed in each patient. All diagnostic data were recorded on PC for subsequent specificity/sensitivity analysis. A total of 105 ventilations in 35 patients with lung injury were analysed. With the threshold D-value of 0.1, the system showed a 100% sensitivity and specificity to diagnose tube location. The algorithm retained its specificity in patients with decreased pulmonary compliance. We also demonstrated the feasibility to integrate sensors and diagnostic hardware in a small, portable hand-held device for convenient use in emergency situations. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  19. Role of imprint cytology in intra operative diagnosis of thyroid lesions.

    PubMed

    Anila, K R; Krishna, G

    2014-07-01

    Intra-operative imprint cytology is an important diagnostic modality in the diagnosis of thyroid lesions. A correct intra-operative diagnosis helps eliminate the need for second surgery. To study diagnostic accuracy of imprint cytology and to compare the imprint cytology results with that of the corresponding paraffin section diagnosis in thyroidectomy cases. This is a prospective study of 84 patients who have undergone thyroidectomies over a period of one year at the Department of Surgery, Thiruvananthapuram, Kerala, India. The intraoperative imprint cytology smears were stained by Papanicolaou method. The imprint cytology interpretation was later compared with the paraffin section diagnosis. Of the 84 patients using haematoxylin and eosin stained histopathology sections as the gold standard, the diagnostic sensitivity of imprint cytology was 75% and specificity was 100%. Positive predictive value was 100%. Negative predictive value was 98.74%. Imprint cytology has high sensitivity and specificity in diagnosing lesions of the thyroid. The problems faced were in diagnosing follicular carcinomas and differentiating low grade lymphoma from lymphocytic thyroiditis. Imprint cytology is a simple, reliable diagnostic technique. It has high sensitivity and specificity in intra-operative diagnosis of lesions of thyroid. In spite of the advent of newer diagnostic modalities like frozen sections, imprint cytology still holds its unique position in the current perspective.

  20. Making a structured psychiatric diagnostic interview faithful to the nomenclature.

    PubMed

    Robins, Lee N; Cottler, Linda B

    2004-10-15

    Psychiatric diagnostic interviews to be used in epidemiologic studies by lay interviewers have, since the 1970s, attempted to operationalize existing psychiatric nomenclatures. How to maximize the chances that they do so successfully has not previously been spelled out. In this article, the authors discuss strategies for each of the seven steps involved in writing, updating, or modifying a diagnostic interview and its supporting materials: 1) writing questions that match the nomenclature's criteria, 2) checking that respondents will be willing and able to answer the questions, 3) choosing a format acceptable to interviewers that maximizes accurate answering and recording of answers, 4) constructing a data entry and cleaning program that highlights errors to be corrected, 5) creating a diagnostic scoring program that matches the nomenclature's algorithms, 6) developing an interviewer training program that maximizes reliability, and 7) computerizing the interview. For each step, the authors discuss how to identify errors, correct them, and validate the revisions. Although operationalization will never be perfect because of ambiguities in the nomenclature, specifying methods for minimizing divergence from the nomenclature is timely as users modify existing interviews and look forward to updating interviews based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition, and the International Classification of Diseases, Eleventh Revision.

  1. Quantum Cascade Laser-Based Infrared Microscopy for Label-Free and Automated Cancer Classification in Tissue Sections.

    PubMed

    Kuepper, Claus; Kallenbach-Thieltges, Angela; Juette, Hendrik; Tannapfel, Andrea; Großerueschkamp, Frederik; Gerwert, Klaus

    2018-05-16

    A feasibility study using a quantum cascade laser-based infrared microscope for the rapid and label-free classification of colorectal cancer tissues is presented. Infrared imaging is a reliable, robust, automated, and operator-independent tissue classification method that has been used for differential classification of tissue thin sections identifying tumorous regions. However, long acquisition time by the so far used FT-IR-based microscopes hampered the clinical translation of this technique. Here, the used quantum cascade laser-based microscope provides now infrared images for precise tissue classification within few minutes. We analyzed 110 patients with UICC-Stage II and III colorectal cancer, showing 96% sensitivity and 100% specificity of this label-free method as compared to histopathology, the gold standard in routine clinical diagnostics. The main hurdle for the clinical translation of IR-Imaging is overcome now by the short acquisition time for high quality diagnostic images, which is in the same time range as frozen sections by pathologists.

  2. Efficiency of Nested-PCR in Detecting Asymptomatic Cases toward Malaria Elimination Program in an Endemic Area of Iran.

    PubMed

    Turki, Habibollah; Raeisi, Ahmad; Malekzadeh, Kianoosh; Ghanbarnejad, Amin; Zoghi, Samaneh; Yeryan, Masoud; Abedi Nejad, Masoumeh; Mohseni, Fatemeh; Shekari, Mohammad

    2015-01-01

    The aim of this study was to detect low parasite and asymptomatic malaria infections by means of three malaria diagnostic tests, in a low transmission region of Minab district, Hormozgan Province, southern Iran. Blood samples of 200 healthy volunteers from Bagh-e-Malek area were evaluated using microscopic, rapid diagnostic tests (RDT) and nested-PCR to inspect malaria parasite. The results showed no Plasmodium parasite in subjects by means of microscopy and RDT. However, 3 P. vivax positive samples (1.5%) were discovered by Nested-PCR while microscopy and RDT missed the cases. Microscopy as the gold standard method and RDT correctly identified 98.5% of cases, and molecular analysis is sensitive and reliable, especially in the detection of "asymptomatic" infections for active case surveillance. Regarding the existence of asymptomatic malaria in endemic area of Hormozgan, Iran, nested-PCR could be considered as a sensitive tool to interrupt malaria transmission in the country, beside the microscopic and RDT methods.

  3. Dermoscopy, Digital Dermoscopy and Other Diagnostic Tools in the Early Detection of Melanoma and Follow-up of High-risk Skin Cancer Patients.

    PubMed

    Thomas, Luc; Puig, Susana

    2017-07-05

    Early detection is a key strategy for reducing the mortality and economic burden associated with melanoma. Dermoscopy is a non-invasive and cost-effective tool for melanoma diagnosis, which has been shown to be a reliable and sensitive method for detecting early-stage skin cancer and reducing the number of unnecessary excisions. Patients at high risk of developing melanoma require long-term surveillance. Use of digital dermoscopy follow-up of these patients has led to improved outcomes. Combined follow-up programmes using total-body photography and digital dermoscopy have led to further improvements in early diagnosis and diagnostic accuracy. Dermoscopy is now widely used by dermatologists, but the public health impact of this tool is yet to be evaluated. Despite the clear advantages of dermoscopy and digital follow-up meth-ods, dermoscopy training and access to digital dermoscopy among dermatologists and general practitioners needs to be improved.

  4. Developmentally Sensitive Diagnostic Criteria for Mental Health Disorders in Early Childhood: The Diagnostic and Statistical Manual of Mental Disorders-IV, the Research Diagnostic Criteria-Preschool Age, and the Diagnostic Classification of Mental Health and Developmental Disorders of Infancy and Early Childhood-Revised

    ERIC Educational Resources Information Center

    Egger, Helen L.; Emde, Robert N.

    2011-01-01

    As the infant mental health field has turned its focus to the presentation, course, and treatment of clinically significant mental health disorders, the need for reliable and valid criteria for identifying and assessing mental health symptoms and disorders in early childhood has become urgent. In this article we offer a critical perspective on…

  5. Systematic review and meta-analysis: rapid diagnostic tests versus placental histology, microscopy and PCR for malaria in pregnant women.

    PubMed

    Kattenberg, Johanna H; Ochodo, Eleanor A; Boer, Kimberly R; Schallig, Henk Dfh; Mens, Petra F; Leeflang, Mariska Mg

    2011-10-28

    During pregnancy, malaria infection with Plasmodium falciparum or Plasmodium vivax is related to adverse maternal health and poor birth outcomes. Diagnosis of malaria, during pregnancy, is complicated by the absence or low parasite densities in peripheral blood. Diagnostic methods, other than microscopy, are needed for detection of placental malaria. Therefore, the diagnostic accuracy of rapid diagnostic tests (RDTs), detecting antigen, and molecular techniques (PCR), detecting DNA, for the diagnosis of Plasmodium infections in pregnancy was systematically reviewed. MEDLINE, EMBASE and Web of Science were searched for studies assessing the diagnostic accuracy of RDTs, PCR, microscopy of peripheral and placental blood and placental histology for the detection of malaria infection (all species) in pregnant women. The results of 49 studies were analysed in metandi (Stata), of which the majority described P. falciparum infections. Although both placental and peripheral blood microscopy cannot reliably replace histology as a reference standard for placental P. falciparum infection, many studies compared RDTs and PCR to these tests. The proportion of microscopy positives in placental blood (sensitivity) detected by peripheral blood microscopy, RDTs and PCR are respectively 72% [95% CI 62-80], 81% [95% CI 55-93] and 94% [95% CI 86-98]. The proportion of placental blood microscopy negative women that were negative in peripheral blood microscopy, RDTs and PCR (specificity) are 98% [95% CI 95-99], 94% [95% CI 76-99] and 77% [95% CI 71-82]. Based on the current data, it was not possible to determine if the false positives in RDTs and PCR are caused by sequestered parasites in the placenta that are not detected by placental microscopy. The findings suggest that RDTs and PCR may have good performance characteristics to serve as alternatives for the diagnosis of malaria in pregnancy, besides any other limitations and practical considerations concerning the use of these tests. Nevertheless, more studies with placental histology as reference test are urgently required to reliably determine the accuracy of RDTs and PCR for the diagnosis of placental malaria. P. vivax-infections have been neglected in diagnostic test accuracy studies of malaria in pregnancy.

  6. A Psychometric Study of the Bayley Scales of Infant and Toddler Development in Persian Language Children

    PubMed Central

    AZARI, Nadia; SOLEIMANI, Farin; VAMEGHI, Roshanak; SAJEDI, Firoozeh; SHAHSHAHANI, Soheila; KARIMI, Hossein; KRASKIAN, Adis; SHAHROKHI, Amin; TEYMOURI, Robab; GHARIB, Masoud

    2017-01-01

    Objective Bayley Scales of infant & toddler development is a well-known diagnostic developmental assessment tool for children aged 1–42 months. Our aim was investigating the validity & reliability of this scale in Persian speaking children. Materials & Methods The method was descriptive-analytic. Translation- back translation and cultural adaptation was done. Content & face validity of translated scale was determined by experts’ opinions. Overall, 403 children aged 1 to 42 months were recruited from health centers of Tehran, during years of 2013-2014 for developmental assessment in cognitive, communicative (receptive & expressive) and motor (fine & gross) domains. Reliability of scale was calculated through three methods; internal consistency using Cronbach’s alpha coefficient, test-retest and interrater methods. Construct validity was calculated using factor analysis and comparison of the mean scores methods. Results Cultural and linguistic changes were made in items of all domains especially on communication subscale. Content and face validity of the test were approved by experts’ opinions. Cronbach’s alpha coefficient was above 0.74 in all domains. Pearson correlation coefficient in various domains, were ≥ 0.982 in test retest method, and ≥0.993 in inter-rater method. Construct validity of the test was approved by factor analysis. Moreover, the mean scores for the different age groups were compared and statistically significant differences were observed between mean scores of different age groups, that confirms validity of the test. Conclusion The Bayley Scales of Infant and Toddler Development is a valid and reliable tool for child developmental assessment in Persian language children. PMID:28277556

  7. Chapter 15: Disease Gene Prioritization

    PubMed Central

    Bromberg, Yana

    2013-01-01

    Disease-causing aberrations in the normal function of a gene define that gene as a disease gene. Proving a causal link between a gene and a disease experimentally is expensive and time-consuming. Comprehensive prioritization of candidate genes prior to experimental testing drastically reduces the associated costs. Computational gene prioritization is based on various pieces of correlative evidence that associate each gene with the given disease and suggest possible causal links. A fair amount of this evidence comes from high-throughput experimentation. Thus, well-developed methods are necessary to reliably deal with the quantity of information at hand. Existing gene prioritization techniques already significantly improve the outcomes of targeted experimental studies. Faster and more reliable techniques that account for novel data types are necessary for the development of new diagnostics, treatments, and cure for many diseases. PMID:23633938

  8. Estimating Classification Consistency and Accuracy for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Cui, Ying; Gierl, Mark J.; Chang, Hua-Hua

    2012-01-01

    This article introduces procedures for the computation and asymptotic statistical inference for classification consistency and accuracy indices specifically designed for cognitive diagnostic assessments. The new classification indices can be used as important indicators of the reliability and validity of classification results produced by…

  9. Investigation of a Diagnostic for Perturbation Theory: Comparison to the T(sub 1) Diagnostic of Coupled-Cluster Theory

    NASA Technical Reports Server (NTRS)

    Lee, Timothy J.; Head-Gordon, Martin; Rendell, Alistair P.; Langhoff, Stephen R. (Technical Monitor)

    1995-01-01

    A diagnostic for perturbation theory calculations, S(sub 2), is defined and numerical results are compared to the established T(sub 1) diagnostic from coupled-cluster theory. S(sub 2) is the lowest order non-zero contribution to a perturbation expansion of T(sub 1). S(sub 2) is a reasonable estimate of the importance of non-dynamical electron correlation, although not as reliable as T(sub 1). S(sub 2) values less than or equal to 0.012 suggest that low orders of perturbation theory should yield reasonable results; S(sub 2) values between 0.012-0.015 suggest that caution is required in interpreting results from low orders of perturbation theory; S(sub 2) values greater than or equal to 0.015 indicate that low orders of perturbation theory are not reliable for accurate results. Although not required mathematically, S(sub 2) is always less than T(sub 1) for the examples studied here.

  10. panelcn.MOPS: Copy-number detection in targeted NGS panel data for clinical diagnostics.

    PubMed

    Povysil, Gundula; Tzika, Antigoni; Vogt, Julia; Haunschmid, Verena; Messiaen, Ludwine; Zschocke, Johannes; Klambauer, Günter; Hochreiter, Sepp; Wimmer, Katharina

    2017-07-01

    Targeted next-generation-sequencing (NGS) panels have largely replaced Sanger sequencing in clinical diagnostics. They allow for the detection of copy-number variations (CNVs) in addition to single-nucleotide variants and small insertions/deletions. However, existing computational CNV detection methods have shortcomings regarding accuracy, quality control (QC), incidental findings, and user-friendliness. We developed panelcn.MOPS, a novel pipeline for detecting CNVs in targeted NGS panel data. Using data from 180 samples, we compared panelcn.MOPS with five state-of-the-art methods. With panelcn.MOPS leading the field, most methods achieved comparably high accuracy. panelcn.MOPS reliably detected CNVs ranging in size from part of a region of interest (ROI), to whole genes, which may comprise all ROIs investigated in a given sample. The latter is enabled by analyzing reads from all ROIs of the panel, but presenting results exclusively for user-selected genes, thus avoiding incidental findings. Additionally, panelcn.MOPS offers QC criteria not only for samples, but also for individual ROIs within a sample, which increases the confidence in called CNVs. panelcn.MOPS is freely available both as R package and standalone software with graphical user interface that is easy to use for clinical geneticists without any programming experience. panelcn.MOPS combines high sensitivity and specificity with user-friendliness rendering it highly suitable for routine clinical diagnostics. © 2017 The Authors. Human Mutation published by Wiley Periodicals, Inc.

  11. panelcn.MOPS: Copy‐number detection in targeted NGS panel data for clinical diagnostics

    PubMed Central

    Povysil, Gundula; Tzika, Antigoni; Vogt, Julia; Haunschmid, Verena; Messiaen, Ludwine; Zschocke, Johannes; Klambauer, Günter; Wimmer, Katharina

    2017-01-01

    Abstract Targeted next‐generation‐sequencing (NGS) panels have largely replaced Sanger sequencing in clinical diagnostics. They allow for the detection of copy‐number variations (CNVs) in addition to single‐nucleotide variants and small insertions/deletions. However, existing computational CNV detection methods have shortcomings regarding accuracy, quality control (QC), incidental findings, and user‐friendliness. We developed panelcn.MOPS, a novel pipeline for detecting CNVs in targeted NGS panel data. Using data from 180 samples, we compared panelcn.MOPS with five state‐of‐the‐art methods. With panelcn.MOPS leading the field, most methods achieved comparably high accuracy. panelcn.MOPS reliably detected CNVs ranging in size from part of a region of interest (ROI), to whole genes, which may comprise all ROIs investigated in a given sample. The latter is enabled by analyzing reads from all ROIs of the panel, but presenting results exclusively for user‐selected genes, thus avoiding incidental findings. Additionally, panelcn.MOPS offers QC criteria not only for samples, but also for individual ROIs within a sample, which increases the confidence in called CNVs. panelcn.MOPS is freely available both as R package and standalone software with graphical user interface that is easy to use for clinical geneticists without any programming experience. panelcn.MOPS combines high sensitivity and specificity with user‐friendliness rendering it highly suitable for routine clinical diagnostics. PMID:28449315

  12. AF-DHNN: Fuzzy Clustering and Inference-Based Node Fault Diagnosis Method for Fire Detection

    PubMed Central

    Jin, Shan; Cui, Wen; Jin, Zhigang; Wang, Ying

    2015-01-01

    Wireless Sensor Networks (WSNs) have been utilized for node fault diagnosis in the fire detection field since the 1990s. However, the traditional methods have some problems, including complicated system structures, intensive computation needs, unsteady data detection and local minimum values. In this paper, a new diagnosis mechanism for WSN nodes is proposed, which is based on fuzzy theory and an Adaptive Fuzzy Discrete Hopfield Neural Network (AF-DHNN). First, the original status of each sensor over time is obtained with two features. One is the root mean square of the filtered signal (FRMS), the other is the normalized summation of the positive amplitudes of the difference spectrum between the measured signal and the healthy one (NSDS). Secondly, distributed fuzzy inference is introduced. The evident abnormal nodes’ status is pre-alarmed to save time. Thirdly, according to the dimensions of the diagnostic data, an adaptive diagnostic status system is established with a Fuzzy C-Means Algorithm (FCMA) and Sorting and Classification Algorithm to reducing the complexity of the fault determination. Fourthly, a Discrete Hopfield Neural Network (DHNN) with iterations is improved with the optimization of the sensors’ detected status information and standard diagnostic levels, with which the associative memory is achieved, and the search efficiency is improved. The experimental results show that the AF-DHNN method can diagnose abnormal WSN node faults promptly and effectively, which improves the WSN reliability. PMID:26193280

  13. Test-treatment RCTs are susceptible to bias: a review of the methodological quality of randomized trials that evaluate diagnostic tests.

    PubMed

    Ferrante di Ruffano, Lavinia; Dinnes, Jacqueline; Sitch, Alice J; Hyde, Chris; Deeks, Jonathan J

    2017-02-24

    There is a growing recognition for the need to expand our evidence base for the clinical effectiveness of diagnostic tests. Many international bodies are calling for diagnostic randomized controlled trials to provide the most rigorous evidence of impact to patient health. Although these so-called test-treatment RCTs are very challenging to undertake due to their methodological complexity, they have not been subjected to a systematic appraisal of their methodological quality. The extent to which these trials may be producing biased results therefore remains unknown. We set out to address this issue by conducting a methodological review of published test-treatment trials to determine how often they implement adequate methods to limit bias and safeguard the validity of results. We ascertained all test-treatment RCTs published 2004-2007, indexed in CENTRAL, including RCTs which randomized patients to diagnostic tests and measured patient outcomes after treatment. Tests used for screening, monitoring or prognosis were excluded. We assessed adequacy of sequence generation, allocation concealment and intention-to-treat, appropriateness of primary analyses, blinding and reporting of power calculations, and extracted study characteristics including the primary outcome. One hundred three trials compared 105 control with 119 experimental interventions, and reported 150 primary outcomes. Randomization and allocation concealment were adequate in 57 and 37% of trials. Blinding was uncommon (patients 5%, clinicians 4%, outcome assessors 21%), as was an adequate intention-to-treat analysis (29%). Overall 101 of 103 trials (98%) were at risk of bias, as judged using standard Cochrane criteria. Test-treatment trials are particularly susceptible to attrition and inadequate primary analyses, lack of blinding and under-powering. These weaknesses pose much greater methodological and practical challenges to conducting reliable RCT evaluations of test-treatment strategies than standard treatment interventions. We suggest a cautious approach that first examines whether a test-treatment intervention can accommodate the methodological safeguards necessary to minimize bias, and highlight that test-treatment RCTs require different methods to ensure reliability than standard treatment trials. Please see the companion paper to this article: http://bmcmedresmethodol.biomedcentral.com/articles/10.1186/s12874-016-0286-0 .

  14. Light-scattering analysis of ultrasonic wave's influence on the RBC agglutination in vitro

    NASA Astrophysics Data System (ADS)

    Doubrovski, Valeri A.; Dvoretski, Costanten N.

    1999-04-01

    Elastic light scattering is one of the most often used optical methods to analyze the cells agglutination reaction - the base of a great number of medical diagnostic test and biomedical investigations. The increase of the resolution of methods and apparatus towards the induced cells aggregation - the foundation of the reaction of agglutination, is quite an actual problem. The solution of this problem increases the reliability of the diagnostic test and gives an opportunity to achieve the diagnostic information in the cases when the traditional approaches do not lead to the diagnostic results. The attempt to increase the resolution of the immune reaction analyzer by means of ultrasonic waves action on the reagent mixture in vitro is taken in this paper. The RBC agglutination reaction which is usually used for the blood group type examination is chosen as an example of an object of the investigation. Different laser optical trains of the devices based on the turbidimetric and nephelometric methods and their combination are analyzed here. The influence of the ultrasonic wave time interval action and of the features of the sample preparation procedure on the resolution towards the agglutination process was investigated in this work. It is shown that the ultrasonic wave action on the reagent mixture leads to a large gain in the resolution of the device towards the RBC agglutination process. The experiments showed that the resolution of the device was enough to register the agglutination process even for the erythrocytes with weak agglutination ability when the reaction was invisible without ultrasonic action. It occurred that the diagnostic test time was more than by an order shortened due to the ultrasonic wave action. The optimal ultrasonic time interval action, the sample preparation technology and experimental technique were defined. The principle of the ultrasonic wave action on the cells agglutination process suggested here can be spread out on the immune molecular media. The results may be useful to develop new apparatus and methods for the aims of medical laboratory diagnostics.

  15. Diagnostic accuracy of three monoclonal stool tests in a large series of untreated Helicobacter pylori infected patients.

    PubMed

    Lario, Sergio; Ramírez-Lázaro, María José; Montserrat, Antònia; Quílez, María Elisa; Junquera, Félix; Martínez-Bauer, Eva; Sanfeliu, Isabel; Brullet, Enric; Campo, Rafael; Segura, Ferran; Calvet, Xavier

    2016-06-01

    Immunochromatographic tests need to be improved in order to enhance their reliability. Recently, several new kits have appeared on the market. The objective was to evaluate the diagnostic accuracy of three monoclonal rapid stool tests - the new Uni-Gold™ H.pylori Antigen (Trinity Biotech, Ireland), the RAPID Hp StAR (Oxoid Ltd., UK) and the ImmunoCard STAT! HpSA (Meridian Diagnostics, USA) - for detecting H. pylori infection prior to eradication treatment. Diagnostic accuracy (sensitivity and specificity) and reliability (concordance between observers) were evaluated in 250 untreated consecutive dyspeptic patients. The gold standard for diagnosing H. pylori infection was defined as the concordance of two or more of rapid urease test (RUT), histopathology and urease breath test (UBT) or positive culture in isolation. Readings of immunochromatographic tests were performed by two different observers. Sensitivity, specificity, positive and negative predictive values and 95% confidence intervals were calculated. Sensitivity and specificity were compared using the McNemar test. The three tests showed a good correlation, with Kappa values>0.9. RAPID Hp StAR had a sensitivity of 91%-92% and a specificity ranging from 77% to 85%. Its sensitivity was higher than that of Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA (p<0.01). Uni-Gold™ H.pylori Antigen kit showed a sensitivity of 83%, similar to ImmunoCard STAT! HpSA. Specificity of Uni-Gold™ H.pylori Antigen approached 90% (87-89%) and was superior to that of RAPID Hp StAR (p<0.01). Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA present similar levels of diagnostic accuracy. RAPID Hp StAR was the most sensitive but less reliable of the three immunochromatographic stool tests. None are as accurate and reliable as UBT, RUT and histology. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Reliability and diagnostic validity of the slump knee bend neurodynamic test for upper/mid lumbar nerve root compression: a pilot study.

    PubMed

    Trainor, Kate; Pinnington, Mark A

    2011-03-01

    It has been proposed that neurodynamic examination can assist differential diagnosis of upper/mid lumbar nerve root compression; however, the diagnostic validity of many of these tests has yet to be established. This pilot study aimed to establish the diagnostic validity of the slump knee bend neurodynamic test for upper/mid lumbar nerve root compression in subjects with suspected lumbosacral radicular pain. Two independent examiners performed the slump knee bend test on subjects with radicular leg pain. Inter-tester reliability was calculated using the kappa coefficient. Slump knee bend test results were compared with magnetic resonance imaging findings, and diagnostic accuracy measures were calculated including sensitivity, specificity, predictive values and likelihood ratios. Orthopaedic spinal clinic, secondary care. Sixteen patients with radicular leg pain. All four subjects with mid lumbar nerve root compression on magnetic resonance imaging were correctly identified with the slump knee bend test; however, it was falsely positive in two individuals without the condition. Inter-tester reliability for the slump knee bend test using the kappa coefficient was 0.71 (95% confidence interval 0.33 to 1.0). Diagnostic validity calculations for the slump knee bend test (95% confidence intervals) were: sensitivity, 100% (40 to 100%); specificity, 83% (52 to 98%); positive predictive value, 67% (22 to 96%); negative predictive value, 100% (69 to 100%); positive likelihood ratio, 6.0 (1.58 to 19.4); and negative likelihood ratio, 0 (0 to 0.6). Results indicate good inter-tester reliability and suggest that the slump knee bend test has potential to be a useful clinical test for identifying patients with mid lumbar nerve root compression. Further investigation is needed on larger numbers of patients to confirm these findings. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  17. [Validation of the German version of the Singing Voice Handicap Index].

    PubMed

    Lorenz, A; Kleber, B; Büttner, M; Fuchs, M; Mürbe, D; Richter, B; Sandel, M; Nawka, T

    2013-08-01

    The Singing Voice Handicap Index (SVHI) was developed in the United States for the self-assessment of patients with singing problems. It has been translated into German and its reliability and validity have been assessed. In total, 54 (35 female, 19 male) dysphonic singers and 130 (74 female, 56 male) non-dysphonic professional singers were included in the study. Reliability rested on high test-retest reliability (r = 0.960, p ≤ 0.001, Pearson correlation) and a Cronbach's α of 0.975. A principal component analysis using the Varimax method and the results of the screeplot suggest the SVHI scored as a single scale. Validity rested on a highly significant correlation between the severity of the self-rated voice impairment by the patient and the total SVHI score. Dysphonic singers have significantly higher SVHI scores than healthy singers. The SVHI is thus suited to implementation as a diagnostic tool in German-speaking countries.

  18. Neuropsychological Criteria for Mild Cognitive Impairment Improves Diagnostic Precision, Biomarker Associations, and Progression Rates

    PubMed Central

    Bondi, Mark W.; Edmonds, Emily C.; Jak, Amy J.; Clark, Lindsay R.; Delano-Wood, Lisa; McDonald, Carrie R.; Nation, Daniel A.; Libon, David J.; Au, Rhoda; Galasko, Douglas; Salmon, David P.

    2014-01-01

    We compared two methods of diagnosing mild cognitive impairment (MCI): conventional Petersen/Winblad criteria as operationalized by the Alzheimer’s Disease Neuroimaging Initiative (ADNI) and an actuarial neuropsychological method put forward by Jak and Bondi designed to balance sensitivity and reliability. 1,150 ADNI participants were diagnosed at baseline as cognitively normal (CN) or MCI via ADNI criteria (MCI: n = 846; CN: n = 304) or Jak/Bondi criteria (MCI: n = 401; CN: n = 749), and the two MCI samples were submitted to cluster and discriminant function analyses. Resulting cluster groups were then compared and further examined for APOE allelic frequencies, cerebrospinal fluid (CSF) Alzheimer’s disease (AD) biomarker levels, and clinical outcomes. Results revealed that both criteria produced a mildly impaired Amnestic subtype and a more severely impaired Dysexecutive/Mixed subtype. The neuropsychological Jak/Bondi criteria uniquely yielded a third Impaired Language subtype, whereas conventional Petersen/Winblad ADNI criteria produced a third subtype comprising nearly one-third of the sample that performed within normal limits across the cognitive measures, suggesting this method’s susceptibility to false positive diagnoses. MCI participants diagnosed via neuropsychological criteria yielded dissociable cognitive phenotypes, significant CSF AD biomarker associations, more stable diagnoses, and identified greater percentages of participants who progressed to dementia than conventional MCI diagnostic criteria. Importantly, the actuarial neuropsychological method did not produce a subtype that performed within normal limits on the cognitive testing, unlike the conventional diagnostic method. Findings support the need for refinement of MCI diagnoses to incorporate more comprehensive neuropsychological methods, with resulting gains in empirical characterization of specific cognitive phenotypes, biomarker associations, stability of diagnoses, and prediction of progression. Refinement of MCI diagnostic methods may also yield gains in biomarker and clinical trial study findings because of improvements in sample compositions of ‘true positive’ cases and removal of ‘false positive’ cases. PMID:24844687

  19. International Standards and Reference Materials for Quantitative Molecular Infectious Disease Testing

    PubMed Central

    Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.

    2010-01-01

    The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208

  20. Quantitative diagnostics of soft tissue through viscoelastic characterization using time-based instrumented palpation.

    PubMed

    Palacio-Torralba, Javier; Hammer, Steven; Good, Daniel W; Alan McNeill, S; Stewart, Grant D; Reuben, Robert L; Chen, Yuhang

    2015-01-01

    Although palpation has been successfully employed for centuries to assess soft tissue quality, it is a subjective test, and is therefore qualitative and depends on the experience of the practitioner. To reproduce what the medical practitioner feels needs more than a simple quasi-static stiffness measurement. This paper assesses the capacity of dynamic mechanical palpation to measure the changes in viscoelastic properties that soft tissue can exhibit under certain pathological conditions. A diagnostic framework is proposed to measure elastic and viscous behaviors simultaneously using a reduced set of viscoelastic parameters, giving a reliable index for quantitative assessment of tissue quality. The approach is illustrated on prostate models reconstructed from prostate MRI scans. The examples show that the change in viscoelastic time constant between healthy and cancerous tissue is a key index for quantitative diagnostics using point probing. The method is not limited to any particular tissue or material and is therefore useful for tissue where defining a unique time constant is not trivial. The proposed framework of quantitative assessment could become a useful tool in clinical diagnostics for soft tissue. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. [Polish version of the ADOS (autism diagnostic observation schedule-generic)].

    PubMed

    Chojnicka, Izabela; Płoski, Rafał

    2012-01-01

    The article presents the Polish version of the autism diagnostic observation schedule-generic (ADOS), which together with the autism diagnostic interview-revised (ADI-R) is cited as the "gold standard" for the diagnosis of autism. The ADOS is a standardised, semistructured observation protocol appropriate for children and adults of differing age and language levels. It is linked to ICD-10 and DSM-IV-TR criteria. The ADOS consists of four modules, ranging from module 1 for nonverbal individuals to module 4 for verbally fluent adults. The adequate inter-rater reliability for items has been established. The protocol has high discriminant validity and distinguishes children with pervasive developmental disorders from children, who are outside of the spectrum. Although it does not enable to distinguish individuals with pervasive developmental disorder, unspecified from individuals with childhood autism. The paper presents subsequent steps of the translation process of the original version into Polish, as well as a chosen adaptation strategy of the Polish version. The ADOS is a very useful tool both for clinical diagnosis and for the scientific purpose diagnosis. In this last case it is extremely important to use a standardised method. Until now, there was no standardised diagnostic tool for autism in Poland.

  2. Mass spectrometric profiling of low-molecular-weight volatile compounds--diagnostic potential and latest applications.

    PubMed

    Lechner, Matthias; Rieder, Josef

    2007-01-01

    The theoretical use of mass spectrometric profiling of low-molecular-weight volatile compounds, as one possible method to non-invasively and rapidly diagnose a variety of diseases, such as cancer, infection, and metabolic disorders has greatly raised the profile of this technique over the last ten years. Despite a number of promising results, this technique has not been introduced into common clinical practice yet. The use of mass spectrometric profiling of exhaled air is particularly hampered by various technical problems and basic methodological issues which have only been partially overcome. However, breath analysis aside, recently published studies reveal completely new ideas and concepts on how to establish fast and reliable diagnosis by using this valuable tool. These studies focussed on the headspace screening of various bodily fluids and sample fluids obtained during diagnostic procedures, as well as microbial cell cultures and demonstrated the vast diagnostic potential of this technique in a wide variety of settings, predominantly in vitro. It is the aim of the present review to discuss the most commonly detected low-molecular-weight volatile compounds and to summarize the current potential applications, latest developments and future perspectives of this promising diagnostic approach.

  3. Verification and classification bias interactions in diagnostic test accuracy studies for fine-needle aspiration biopsy.

    PubMed

    Schmidt, Robert L; Walker, Brandon S; Cohen, Michael B

    2015-03-01

    Reliable estimates of accuracy are important for any diagnostic test. Diagnostic accuracy studies are subject to unique sources of bias. Verification bias and classification bias are 2 sources of bias that commonly occur in diagnostic accuracy studies. Statistical methods are available to estimate the impact of these sources of bias when they occur alone. The impact of interactions when these types of bias occur together has not been investigated. We developed mathematical relationships to show the combined effect of verification bias and classification bias. A wide range of case scenarios were generated to assess the impact of bias components and interactions on total bias. Interactions between verification bias and classification bias caused overestimation of sensitivity and underestimation of specificity. Interactions had more effect on sensitivity than specificity. Sensitivity was overestimated by at least 7% in approximately 6% of the tested scenarios. Specificity was underestimated by at least 7% in less than 0.1% of the scenarios. Interactions between verification bias and classification bias create distortions in accuracy estimates that are greater than would be predicted from each source of bias acting independently. © 2014 American Cancer Society.

  4. Can the Fatigue Severity Scale 7-item version be used across different patient populations as a generic fatigue measure - a comparative study using a Rasch model approach

    PubMed Central

    2014-01-01

    Background Fatigue is a disabling symptom associated with reduced quality of life in various populations living with chronic illnesses. The transfer of knowledge about fatigue from one group to another is crucial in both research and healthcare. Outcomes should be validly and reliably comparable between groups and should not be unduly influenced by diagnostic variations. The present study evaluates whether the Fatigue Severity Scale 7-item version (FSS-7) demonstrates similar item hierarchy across people with multiple sclerosis, stroke or HIV/AIDS to ensure valid comparisons between groups, and provide further evidence of internal scale validity. Methods A secondary comparative analysis was performed using data from three different studies of three different chronic illnesses: multiple sclerosis, stroke and HIV/AIDS. Each of these studies had previously concluded that the FSS-7 has better psychometric properties than the original FSS for measuring fatigue interference. Data from 224 people with multiple sclerosis, 104 people with stroke and 316 people with HIV/AIDS were examined. Item response theory and a Rasch model were chosen to analyze the similarity of the FSS-7 item hierarchy across the three diagnostic groups Results Cross-sample differences were found for items #3, #5, #6 and #9 for two of the three samples, which raise questions about item validity across groups. However, disease-specific and disease-generic Rasch measures were similar across samples, indicating that individual fatigue interference measures in these three chronic illnesses might still be reliably comparable using the FSS-7. Conclusions Some items performed differently between the three samples but did not bias person measures, thereby indicating that fatigue interference in these illnesses might still be reliably compared using FSS-7 scores. However, caution is warranted when comparing fatigue raw sum scores directly across diagnostic groups using the FSS-7. Further studies of the scale are needed in other types of chronic illnesses. PMID:24559076

  5. Development of a Chinese medicine assessment measure: an interdisciplinary approach using the delphi method.

    PubMed

    Schnyer, Rosa N; Conboy, Lisa A; Jacobson, Eric; McKnight, Patrick; Goddard, Thomas; Moscatelli, Francesca; Legedza, Anna T R; Kerr, Catherine; Kaptchuk, Ted J; Wayne, Peter M

    2005-12-01

    The diagnostic framework and clinical reasoning process in Chinese medicine emphasizes the contextual and qualitative nature of a patient's illness. Chinese medicine assessment data may help interpret clinical outcomes. As part of a study aimed at assessing the validity and improving the inter-rater reliability of the Chinese diagnostic process, a structured assessment instrument was developed for use in clinical trials of acupuncture and other Chinese medical therapies. To foster collaboration and maximize resources and information, an interdisciplinary advisory team was assembled. Under the guidance of two group process facilitators, and in order to establish whether the assessment instrument was consistent with accepted Chinese medicine diagnostic categories (face validity) and included the full range of each concept's meaning (content validity), a panel of Traditional Chinese Medicine (TCM) expert clinicians was convened and their responses were organized using the Delphi process, an iterative, anonymous, idea-generating and consensus-building process. An aggregate rating measure was obtained by taking the mean of mean ratings for each question across all 10 experts. Over three rounds, the overall rating increased from 7.4 (SD = 1.3) in Round 1 to 9.1 (SD = 0.5) in Round 3. The level of agreement among clinicians was measured by a decrease in SD. The final instrument TEAMSI-TCM (Traditional East Asian Medicine Structured Interview, TCM version) uses the pattern differentiation model characteristic of TCM. This modular, dynamic version was specifically designed to assess women, with a focus on gynecologic conditions; with modifications it can be adapted for use with other populations and conditions. TEAMSI-TCM is a prescriptive instrument that guides clinicians to use the proper indicators, combine them in a systematic manner, and generate conclusions. In conjunction with treatment manualization and training it may serve to increase inter-rater reliability and inter-trial reproducibility in Chinese medicine clinical trials. Testing of the validity and reliability of this instrument currently is underway.

  6. Objective evaluation of cervical vertebral bone age' its reliability in comparison with hand-wrist bone age: by TW3 method.

    PubMed

    Prasad, Cms Krishna; Reddy, Vamsi Nilay; Sreedevi, Gojja; Ponnada, Swaroopa Rani; Priya, K Padma; Naik, B Raveendra

    2013-09-01

    The aim of this study was to establish the validity of a new method for evaluating skeletal maturation by assessing the 3rd and 4th cervical vertebrae seen in the cephalometric radiograph. This study consisted of a sample of 50 patients in the age group of 8 to 14 years of age. Chronologically, they were divided into six groups, based on the age consisting of a minimum of six to a maximum of 10 subjects. All the patients included in the study were females. The selected subjects were clinically examined and then age and date of birth of the patient in years and months was noted. Then lateral cephalograms and hand-wrist radiographs of the patient were taken on the same day with good clarity and contrast. The results suggested that cervical vertebral bone age on cephalometric radiographs calculated with this method is as reliable at estimating bone age as is the Tanner-Whitehouse 3 (TW3) method on hand-wrist radiographs. By determining the cervical vertebral bone age, skeletal maturity can be evaluated in a detailed and objective manner with cephalometric radiographs. The ability to accurately appraise skeletal maturity from cervical vertebral maturation, without the need for additional radiographs, has the potential to improve orthodontic diagnostic and therapeutic decisions. The technique's simplicity and ease of use should encourage this method as a frst level diagnostic tool to assess skeletal maturation. Clinical signifcance: This study revealed that the timing and sequence of ossifcation of the bones in hand and wrist and cervical vertebrae were able to relate the skeletal development of the various skeletal maturity indicators to a child's development. This method provided a mean with which one can determine the skeletal maturity of a person and thereby determine whether the possibility of potential growth existed.

  7. The global burden of fasciolosis in domestic animals with an outlook on the contribution of new approaches for diagnosis and control.

    PubMed

    Khan, Muhammad Kasib; Sajid, Muhammad Sohail; Riaz, Hasan; Ahmad, Nazia Ehsan; He, Lan; Shahzad, Muhammad; Hussain, Altaf; Khan, Muhammad Nisar; Iqbal, Zafar; Zhao, Junlong

    2013-07-01

    Fasciolosis is an economically important disease for livestock, as well as being zoonotic. Recent figures on the prevalence of this disease have caused alarm concerning its potential for an increased prevalence in the future. The prevalence of fascioliosis has been documented from different regions of the world, helping us identify areas where future research needs to be focused. This manuscript is a review of the current status of the disease, the pathogenic species involved, diagnostic techniques (with new modifications and comparative specificity, sensitivity, and rapidity of these tests), chemotherapy, and vaccination. This also encompasses inaccurate reports on vaccination and drug development as well as the latest technologies to find promising candidates for drugs and vaccines. Drugs with lower efficacy have been used on some farms which lead to exacerbation of the clinical disease, presumably due to the development of drug resistance. Future studies should be focused on (1) the use of the most reliable diagnostic tests for periodic monitoring of the disease, (2) insights of the ecobiology and transmission dynamics of the snail intermediate host and the best possible methods of their control, (3) in vitro and in vivo testing of chemotherapeutic compounds using sensitive methods, and (4) the identification of novel drug and vaccine candidates using modern molecular markers. This approach may help increase the reliability of chemotherapeutic agents and control nuisance, ultimately reducing the economic losses attributable to the livestock industry around the world.

  8. Sex chromosomal abnormalities associated with equine infertility: validation of a simple molecular screening tool in the Purebred Spanish Horse.

    PubMed

    Anaya, G; Molina, A; Valera, M; Moreno-Millán, M; Azor, P; Peral-García, P; Demyda-Peyrás, S

    2017-08-01

    Chromosomal abnormalities in the sex chromosome pair (ECAX and ECAY) are widely associated with reproductive problems in horses. However, a large proportion of these abnormalities remains undiagnosed due to the lack of an affordable diagnostic tool that allows for avoiding karyotyping tests. Hereby, we developed an STR (single-tandem-repeat)-based molecular method to determine the presence of the main sex chromosomal abnormalities in horses in a fast, cheap and reliable way. The frequency of five ECAX-linked (LEX026, LEX003, TKY38, TKY270 and UCDEQ502) and two ECAY-linked (EcaYH12 and SRY) markers was characterized in 261 Purebred Spanish Horses to determine the efficiency of the methodology developed to be used as a chromosomal diagnostic tool. All the microsatellites analyzed were highly polymorphic, with a sizeable number of alleles (polymorphic information content > 0.5). Based on this variability, the methodology showed 100% sensitivity and 99.82% specificity to detect the most important sex chromosomal abnormalities reported in horses (chimerism, Turner's syndrome and sex reversal syndromes). The method was also validated with 100% efficiency in 10 individuals previously diagnosed as chromosomally aberrant. This STR screening panel is an efficient and reliable molecular-cytogenetic tool for the early detection of sex chromosomal abnormalities in equines that could be included in breeding programs to save money, effort and time of veterinary practitioners and breeders. © 2017 Stichting International Foundation for Animal Genetics.

  9. Five Systems of Psychiatric Classification for Preschool Children: Do Differences in Validity, Usefulness and Reliability Make for Competitive or Complimentary Constellations?

    ERIC Educational Resources Information Center

    Postert, Christian; Averbeck-Holocher, Marlies; Beyer, Thomas; Muller, Jorg; Furniss, Tilman

    2009-01-01

    "DSM-IV" and "ICD-10" have limitations in the diagnostic classification of psychiatric disorders at preschool age (0-5 years). The publication of the "Diagnostic Classification 0-3 (DC:0-3)" in 1994, its basically revised second edition ("DC:0-3R") in 2005 and the "Research Diagnostic Criteria-Preschool Age (RDC-PA)" in 2004 have provided several…

  10. Assessing Diagnostic Tests I: You Can't Be Too Sensitive.

    PubMed

    Jupiter, Daniel C

    2015-01-01

    Clinicians and patients are always interested in less invasive, cheaper, and faster diagnostic tests. When introducing such a test, physicians must ensure that it is reliable in its diagnoses and does not commit errors. In this article, I discuss several ways that new tests are compared against gold standard diagnostics. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Psychometric properties of the motor diagnostics in the German football talent identification and development programme.

    PubMed

    HÖner, Oliver; Votteler, Andreas; Schmid, Markus; Schultz, Florian; Roth, Klaus

    2015-01-01

    The utilisation of motor performance tests for talent identification in youth sports is discussed intensively in talent research. This article examines the reliability, differential stability and validity of the motor diagnostics conducted nationwide by the German football talent identification and development programme and provides reference values for a standardised interpretation of the diagnostics results. Highly selected players (the top 4% of their age groups, U12-U15) took part in the diagnostics at 17 measurement points between spring 2004 and spring 2012 (N = 68,158). The heterogeneous test battery measured speed abilities and football-specific technical skills (sprint, agility, dribbling, ball control, shooting, juggling). For all measurement points, the overall score and the speed tests showed high internal consistency, high test-retest reliability and satisfying differential stability. The diagnostics demonstrated satisfying factorial-related validity with plausible and stable loadings on the two empirical factors "speed" and "technical skills". The score, and the technical skills dribbling and juggling, differentiated the most among players of different performance levels and thus showed the highest criterion-related validity. Satisfactory psychometric properties for the diagnostics are an important prerequisite for a scientifically sound rating of players' actual motor performance and for the future examination of the prognostic validity for success in adulthood.

  12. The use of adaptable automation: Effects of extended skill lay-off and changes in system reliability.

    PubMed

    Sauer, Juergen; Chavaillaz, Alain

    2017-01-01

    This experiment aimed to examine how skill lay-off and system reliability would affect operator behaviour in a simulated work environment under wide-range and large-choice adaptable automation comprising six different levels. Twenty-four participants were tested twice during a 2-hr testing session, with the second session taking place 8 months after the first. In the middle of the second testing session, system reliability changed. The results showed that after the retention interval trust increased and self-confidence decreased. Complacency was unaffected by the lay-off period. Diagnostic speed slowed down after the retention interval but diagnostic accuracy was maintained. No difference between experimental conditions was found for automation management behaviour (i.e. level of automation chosen and frequency of switching between levels). There were few effects of system reliability. Overall, the findings showed that subjective measures were more sensitive to the impact of skill lay-off than objective behavioural measures. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Classification of mood disorders in DSM-V and DSM-VI.

    PubMed

    Joyce, Peter R

    2008-10-01

    For any diagnostic system to be clinically useful, and go beyond description, it must provide an understanding that informs about aetiology and/or outcome. DSM-III and DSM-IV have provided reliability; the challenge for DSM-V and DSM-VI will be to provide validity. For DSM-V this will not be achieved. Believers in DSM-III and DSM-IV have impeded progress towards a valid classification system, so DSM-V needs to retain continuity with its predecessors to retain reliability and enhance research, but position itself to inform a valid diagnostic system by DSM-VI. This review examines the features of a diagnostic system and summarizes what is really known about mood disorders. The review also questions whether what are called mood disorders are primarily disorders of mood. Finally, it provides suggestions for DSM-VI.

  14. SvSXP: a Strongylus vulgaris antigen with potential for prepatent diagnosis

    PubMed Central

    2013-01-01

    Background Strongyle parasites are ubiquitous in grazing horses. Strongylus vulgaris, the most pathogenic of the large strongyles, is known for its extensive migration in the mesenteric arterial system. The lifecycle of S. vulgaris is characterised by a long prepatent period where the migrating larvae are virtually undetectable as there currently is no test available for diagnosing prepatent S. vulgaris infection. Presence of S. vulgaris larvae in the arterial system causes endarteritis and thrombosis with a risk of non-strangulating intestinal infarctions. Emergence of anthelmintic resistance among cyathostomins has led to recommendations of reduced treatment intensity by targeting horses that exceed a predetermined strongyle faecal egg count threshold. One study suggests an apparent increase in prevalence of S. vulgaris on farms where reduced anthelmintic treatment intensity has been implemented. These issues highlight the need for an accurate and reliable assay for diagnosing prepatent S. vulgaris infection. Methods Immunoscreening of a larval S. vulgaris cDNA library using hyperimmune serum raised against S. vulgaris excretory/secretory antigens was performed to identify potential diagnostic antigens. Immunoreactive clones were sequenced, one potential antigen was characterised, expressed as a recombinant protein, initially evaluated by western blot (WB) analysis, the diagnostic potential of the IgG subclasses was evaluated by ELISA, and the diagnostic accuracy evaluated using serum from 102 horses with known S. vulgaris infection status. Results The clone expressing the potential antigen encoded a S. vulgaris SXP/RAL2 homologue. The recombinant protein, rSvSXP, was shown to be a potential diagnostic antigen by WB analysis, and a target of serum IgGa, IgG(T) and total IgG in naturally infected horses, with IgG(T) antibodies being the most reliable indicator of S. vulgaris infection in horses. Evaluation of diagnostic accuracy of the ELISA resulted in a sensitivity of 73.3%, a specificity of 81.0%, a diagnostic odds ratio of 11.69; a positive likelihood ratio (LR) of 3.85 and a negative LR was 0.33. The area under the ROC curve was 0.820. Conclusion IgG(T) antibodies to recombinant SvSXP show potential for use as an antigen for prepatent diagnosis of migrating stages of S. vulgaris with moderate to good diagnostic accuracy. PMID:23557195

  15. The Bipolar Affective Disorder Dimension Scale (BADDS) – a dimensional scale for rating lifetime psychopathology in Bipolar spectrum disorders

    PubMed Central

    Craddock, Nick; Jones, Ian; Kirov, George; Jones, Lisa

    2004-01-01

    Background Current operational diagnostic systems have substantial limitations for lifetime diagnostic classification of bipolar spectrum disorders. Issues include: (1) It is difficult to operationalize the integration of diverse episodes of psychopathology, (2) Hierarchies lead to loss of information, (3) Boundaries between diagnostic categories are often arbitrary, (4) Boundaries between categories usually require a major element of subjective interpretation, (5) Available diagnostic categories are relatively unhelpful in distinguishing severity, (6) "Not Otherwise Specified (NOS)" categories are highly heterogeneous, (7) Subclinical cases are not accommodated usefully within the current diagnostic categories. This latter limitation is particularly pertinent in the context of the increasing evidence for the existence of a broader bipolar spectrum than has been acknowledged within existing classifications. Method We have developed a numerical rating system, the Bipolar Affective Disorder Dimension Scale, BADDS, that can be used as an adjunct to conventional best-estimate lifetime diagnostic procedures. The scale definitions were informed by (a) the current concepts of mood syndrome recognized within DSMIV and ICD10, (b) the literature regarding severity of episodes, and (c) our own clinical experience. We undertook an iterative process in which we initially agreed scale definitions, piloted their use on sets of cases and made modifications to improve utility and reliability. Results BADDS has four dimensions, each rated as an integer on a 0 – 100 scale, that measure four key domains of lifetime psychopathology: Mania (M), Depression (D), Psychosis (P) and Incongruence (I). In our experience it is easy to learn, straightforward to use, has excellent inter-rater reliability and retains the key information required to make diagnoses according to DSMIV and ICD10. Conclusions Use of BADDS as an adjunct to conventional categorical diagnosis provides a richer description of lifetime psychopathology that (a) can accommodate sub-clinical features, (b) discriminate between illness severity amongst individuals within a single conventional diagnostic category, and (c) demonstrate the similarity between the illness experience of individuals who have been classified into different disease categories but whose illnesses both fall near the boundaries between the two categories. BADDS may be useful for researchers and clinicians who are interested in description and classification of lifetime psychopathology of individuals with disorders lying on the bipolar spectrum. PMID:15236660

  16. A psychometric evaluation of the Rorschach comprehensive system's perceptual thinking index.

    PubMed

    Dao, Tam K; Prevatt, Frances

    2006-04-01

    In this study, we investigated evidence for reliability and validity of the Perceptual Thinking Index (PTI; Exner, 2000a, 2000b) among an adult inpatient population. We conducted reliability and validity analyses on 107 patients who met the Diagnostic and Statistical Manual of Mental Disorders (4th ed., text revision; American Psychiatric Association, 2000) criteria for a schizophrenia-spectrum disorder (SSD) or mood disorder with no psychotic features (MD). Results provided support for interrater reliability as well as internal consistency of the PTI. Furthermore, the PTI was an effective index in differentiating SSD patients from patients diagnosed with an MD. Finally, the PTI demonstrated adequate diagnostic statistics that can be useful in the classification of patients diagnosed with SSD and MD. We discuss methodological issues, implications for assessment practice, and directions for future research.

  17. Proteome-based bacterial identification using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS): A revolutionary shift in clinical diagnostic microbiology.

    PubMed

    Nomura, Fumio

    2015-06-01

    Rapid and accurate identification of microorganisms, a prerequisite for appropriate patient care and infection control, is a critical function of any clinical microbiology laboratory. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a quick and reliable method for identification of microorganisms, including bacteria, yeast, molds, and mycobacteria. Indeed, there has been a revolutionary shift in clinical diagnostic microbiology. In the present review, the state of the art and advantages of MALDI-TOF MS-based bacterial identification are described. The potential of this innovative technology for use in strain typing and detection of antibiotic resistance is also discussed. This article is part of a Special Issue entitled: Medical Proteomics. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Brief Report: An Exploratory Study of the Diagnostic Reliability for Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Taylor, Lauren J.; Eapen, Valsamma; Maybery, Murray; Midford, Sue; Paynter, Jessica; Quarmby, Lyndsay; Smith, Timothy; Williams, Katrina; Whitehouse, Andrew J.

    2017-01-01

    Previous research shows inconsistency in clinician-assigned diagnoses of Autism Spectrum Disorder (ASD). We conducted an exploratory study that examined the concordance of diagnoses between a multidisciplinary assessment team and a range of independent clinicians throughout Australia. Nine video-taped Autism Diagnostic Observation Schedule (ADOS)…

  19. Cognitive Diagnostic Attribute-Level Discrimination Indices

    ERIC Educational Resources Information Center

    Henson, Robert; Roussos, Louis; Douglas, Jeff; He, Xuming

    2008-01-01

    Cognitive diagnostic models (CDMs) model the probability of correctly answering an item as a function of an examinee's attribute mastery pattern. Because estimation of the mastery pattern involves more than a continuous measure of ability, reliability concepts introduced by classical test theory and item response theory do not apply. The cognitive…

  20. Combined evaluation of commonly used techniques, including PCR, for diagnosis of mouse fur mites.

    PubMed

    Karlsson, Eleanor M; Pearson, Laura M; Kuzma, Kristen M; Burkholder, Tanya H

    2014-01-01

    Our study evaluated and compared the false-negative rates (FNR) of a wide array of fur-mite diagnostic tests, including 2 postmortem tests (pelt exam and sticky paper) and 3 antemortem tests (adhesive tape, fur pluck, and PCR). Past publications examining fur-mite diagnostic techniques primarily used paired comparisons, evaluating tests by their level of agreement with only one other test. However, different combinations or pairs of diagnostics are used in the different studies, making the results of these comparisons difficult to interpret across all available diagnostics. In the current study, mice from a conventionally maintained colony endemic for Myobia musculi were identified as positive based on at least one positive diagnostic test. From this pool of positive animals, the FNR of all tests were quantified. The PCR assay and the pelt exam performed the best, with 0% and 2% FNR respectively, whereas tape, fur-pluck, and sticky-paper tests showed 24%, 26%, and 36% FNR, respectively. Our study shows that for mice in a colony naturally infested with Myobia musculi, PCR testing can be used for reliable antemortem detection, and pelt exam performed by experienced examiners is reliable for postmortem detection.

  1. Digital assessment of the fetal alcohol syndrome facial phenotype: reliability and agreement study.

    PubMed

    Tsang, Tracey W; Laing-Aiken, Zoe; Latimer, Jane; Fitzpatrick, James; Oscar, June; Carter, Maureen; Elliott, Elizabeth J

    2017-01-01

    To examine the three facial features of fetal alcohol syndrome (FAS) in a cohort of Australian Aboriginal children from two-dimensional digital facial photographs to: (1) assess intrarater and inter-rater reliability; (2) identify the racial norms with the best fit for this population; and (3) assess agreement with clinician direct measures. Photographs and clinical data for 106 Aboriginal children (aged 7.4-9.6 years) were sourced from the Lililwan Project . Fifty-eight per cent had a confirmed prenatal alcohol exposure and 13 (12%) met the Canadian 2005 criteria for FAS/partial FAS. Photographs were analysed using the FAS Facial Photographic Analysis Software to generate the mean PFL three-point ABC-Score, five-point lip and philtrum ranks and four-point face rank in accordance with the 4-Digit Diagnostic Code. Intrarater and inter-rater reliability of digital ratings was examined in two assessors. Caucasian or African American racial norms for PFL and lip thickness were assessed for best fit; and agreement between digital and direct measurement methods was assessed. Reliability of digital measures was substantial within (kappa: 0.70-1.00) and between assessors (kappa: 0.64-0.89). Clinician and digital ratings showed moderate agreement (kappa: 0.47-0.58). Caucasian PFL norms and the African American Lip-Philtrum Guide 2 provided the best fit for this cohort. In an Aboriginal cohort with a high rate of FAS, assessment of facial dysmorphology using digital methods showed substantial inter- and intrarater reliability. Digital measurement of features has high reliability and until data are available from a larger population of Aboriginal children, the African American Lip-Philtrum Guide 2 and Caucasian (Strömland) PFL norms provide the best fit for Australian Aboriginal children.

  2. Inter- and intraexaminer reliability of bitewing radiography and near-infrared light transillumination for proximal caries detection and assessment.

    PubMed

    Litzenburger, Friederike; Heck, Katrin; Pitchika, Vinay; Neuhaus, Klaus W; Jost, Fabian N; Hickel, Reinhard; Jablonski-Momeni, Anahita; Welk, Alexander; Lederer, Alexander; Kühnisch, Jan

    2018-02-01

    The purpose of this in vitro study was to evaluate the inter- and intraexaminer reliability of digital bitewing (DBW) radiography and near-infrared light transillumination (NIRT) for proximal caries detection and assessment in posterior teeth. From a pool of 85 patients, 100 corresponding pairs of DBW and NIRT images (~1/3 healthy, ~1/3 with enamel caries and ~1/3 with dentin caries) were chosen. 12 dentists with different professional status and clinical experience repeated the evaluation in two blinded cycles. Two experienced dentists provided a reference diagnosis after analysing all images independently. Statistical analysis included the calculation of simple (κ) and weighted Kappa (wκ) values as a measure of reliability. Logistic regression with a backward elimination model was used to investigate the influence of the diagnostic method, evaluation cycle, type of tooth, and clinical experience on reliability. Altogether, inter- and intraexaminer reliability exhibited good to excellent κ and wκ values for DBW radiography (Inter: κ = 0.60/ 0.63; wκ = 0.74/0.76; Intra: κ = 0.64; wκ = 0.77) and NIRT (Inter: κ = 0.74/0.64; wκ = 0.86/0.82; Intra: κ = 0.68; wκ = 0.84). The backward elimination model revealed NIRT to be significantly more reliable than DBW radiography. This study revealed a good to excellent inter- and intraexaminer reliability for proximal caries detection using DBW and NIRT images. The logistic regression analysis revealed significantly better reliability for NIRT. Additionally, the first evaluation cycle was more reliable according to the reference diagnoses.

  3. Atomic and molecular gas phase spectrometry

    NASA Astrophysics Data System (ADS)

    Winefordner, J. D.

    1985-10-01

    The major goals of this research have been to develop diagnostical spectroscopic methods for measuring spatial/temporal temperatures and species of combustion flames and plasmas and to develop sensitive, selective, precise, reliable, rapid spectrometric methods of trace analysis of elements present in jet engine lubricating oils, metallurgical samples, and engine exhausts. The diagnostical approaches have been based upon the measurement of metal probes introduced into the flame or plasmas and the measurement of OH in flames. The measurement approaches have involved the use of laser-excited fluorescence, saturated absorption, polarization, and linear absorption. The spatial resolution in most studies is less than 1 cu mm and the temporal resolution is less than 10 ns with the use of pulsed lasers. Single pulse temperature and species measurements have also been carried out. Other diagnostical studies have involved the measurement of collisional redistribution of radiatively excited levels of Na and Tl in acetylene/02/Ar flames and the measurement of lifetimes and quantum efficiencies of atoms and ions in the inductively coupled plasmas, ICP. The latter studies indicate that the high electron number densities in ICPs are not efficient quenchers of excited atoms/ions. Temperatures of microwave atmospheric plasmas produced capacitatively and cool metastable N2 discharge produced by a dielectric discharge have also been measured.

  4. Research diagnostic criteria for temporomandibular disorders (RDC/TMD): development of image analysis criteria and examiner reliability for image analysis.

    PubMed

    Ahmad, Mansur; Hollender, Lars; Anderson, Quentin; Kartha, Krishnan; Ohrbach, Richard; Truelove, Edmond L; John, Mike T; Schiffman, Eric L

    2009-06-01

    As part of the Multisite Research Diagnostic Criteria For Temporomandibular Disorders (RDC/TMD) Validation Project, comprehensive temporomandibular joint diagnostic criteria were developed for image analysis using panoramic radiography, magnetic resonance imaging (MRI), and computerized tomography (CT). Interexaminer reliability was estimated using the kappa (kappa) statistic, and agreement between rater pairs was characterized by overall, positive, and negative percent agreement. Computerized tomography was the reference standard for assessing validity of other imaging modalities for detecting osteoarthritis (OA). For the radiologic diagnosis of OA, reliability of the 3 examiners was poor for panoramic radiography (kappa = 0.16), fair for MRI (kappa = 0.46), and close to the threshold for excellent for CT (kappa = 0.71). Using MRI, reliability was excellent for diagnosing disc displacements (DD) with reduction (kappa = 0.78) and for DD without reduction (kappa = 0.94) and good for effusion (kappa = 0.64). Overall percent agreement for pairwise ratings was >or=82% for all conditions. Positive percent agreement for diagnosing OA was 19% for panoramic radiography, 59% for MRI, and 84% for CT. Using MRI, positive percent agreement for diagnoses of any DD was 95% and of effusion was 81%. Negative percent agreement was >or=88% for all conditions. Compared with CT, panoramic radiography and MRI had poor and marginal sensitivity, respectively, but excellent specificity in detecting OA. Comprehensive image analysis criteria for the RDC/TMD Validation Project were developed, which can reliably be used for assessing OA using CT and for disc position and effusion using MRI.

  5. [Information system in the cardio polyclinic].

    PubMed

    Mihajlović, Marina; Zivković, Marija

    2014-03-01

    The cardiologic polyclinic information system ensures effective management of business processes in the polyclinic. Medical nurse provides health care to a patient with the support of the information system, which enables recording the patient's identity, admission, participation fee charges, billing for the services provided, patients' orders for noninvasive diagnostic methods, and implementation of diagnostic methods. The nurse enters patient's personal information at every work station, updates the existing records, and has an opportunity to add notes and insights to the results of patient's diagnostic tests and doctors' opinions for patients in the polyclinic. Additionally, the nurse records the services and supplies provided, and these entries are used for billing and service charges. This information is accessible at every work station to authorized persons exclusively. The implementation of the information system enables medical nurses working at the reception desk and in nurses' consulting room to record administrative data and data related to diagnostic analysis at the moment and at the place they happen. A personal password is required to access these data. In this way, the patient admission recording is facilitated, and in case the patient needs to be contacted, communication with him/her is improved, and finally, writing reports and data analysis are simplified. Apart from the advantages, there also are problems such as inadequate staff education and insufficient reliability of the information infrastructure, which if overloaded, can slow down the system, and this is time consuming for both health workers and patients.

  6. Diagnostic approaches for diabetic cardiomyopathy and myocardial fibrosis

    PubMed Central

    Maya, Lisandro; Villarreal, Francisco J.

    2009-01-01

    In diabetes mellitus, alterations in cardiac structure/function in the absence of ischemic heart disease, hypertension or other cardiac pathologies is termed diabetic cardiomyopathy. In the United States, the prevalence of diabetes mellitus continues to rise and the disease currently affects about 8% of the general population. Hence, it is imperative the use of appropriate diagnostic strategies for diabetic cardiomyopathy, which may help correctly identify the disease at early stages and implement suitable corrective therapies. Currently, there is no single diagnostic method for the identification of diabetic cardiomyopathy. Diabetic cardiomyopathy is known to induce changes in cardiac structure such as, myocardial hypertrophy, fibrosis and fat droplet deposition. Early changes in cardiac function are typically manifested as abnormal diastolic function that with time leads to loss of contractile function. Echocardiography based methods currently stands as the preferred diagnostic approach for diabetic cardiomyopathy, due to its wide availability and economical use. In addition to conventional techniques, magnetic resonance imaging and spectroscopy along with contrast agents are now leading new approaches in the diagnosis of myocardial fibrosis, and cardiac and hepatic metabolic changes. These strategies can be complemented with serum biomarkers so they can offer a clear picture as to diabetes-induced changes in cardiac structure/function even at very early stages of the disease. This review article intends to provide a summary of experimental and routine tools currently available to diagnose diabetic cardiomyopathy induced changes in cardiac structure/function. These tools can be reliably used in either experimental models of diabetes or for clinical applications. PMID:19595694

  7. Next-generation ELISA diagnostic assay for Chagas Disease based on the combination of short peptidic epitopes

    PubMed Central

    Volcovich, Romina; Altcheh, Jaime; Bracamonte, Estefanía; Marco, Jorge D.; Nielsen, Morten; Buscaglia, Carlos A.

    2017-01-01

    Chagas Disease, caused by the protozoan Trypanosoma cruzi, is a major health and economic problem in Latin America for which no vaccine or appropriate drugs for large-scale public health interventions are yet available. Accurate diagnosis is essential for the early identification and follow up of vector-borne cases and to prevent transmission of the disease by way of blood transfusions and organ transplantation. Diagnosis is routinely performed using serological methods, some of which require the production of parasite lysates, parasite antigenic fractions or purified recombinant antigens. Although available serological tests give satisfactory results, the production of reliable reagents remains laborious and expensive. Short peptides spanning linear B-cell epitopes have proven ideal serodiagnostic reagents in a wide range of diseases. Recently, we have conducted a large-scale screening of T. cruzi linear B-cell epitopes using high-density peptide chips, leading to the identification of several hundred novel sequence signatures associated to chronic Chagas Disease. Here, we performed a serological assessment of 27 selected epitopes and of their use in a novel multipeptide-based diagnostic method. A combination of 7 of these peptides were finally evaluated in ELISA format against a panel of 199 sera samples (Chagas-positive and negative, including sera from Leishmaniasis-positive subjects). The multipeptide formulation displayed a high diagnostic performance, with a sensitivity of 96.3% and a specificity of 99.15%. Therefore, the use of synthetic peptides as diagnostic tools are an attractive alternative in Chagas’ disease diagnosis. PMID:28991925

  8. Depression of home cage wheel running: a reliable and clinically relevant method to assess migraine pain in rats.

    PubMed

    Kandasamy, Ram; Lee, Andrea T; Morgan, Michael M

    2017-12-01

    The development of new anti-migraine treatments is limited by the difficulty inassessing migraine pain in laboratory animals. Depression of activity is one of the few diagnostic criteria formigraine that can be mimicked in rats. The goal of the present study was to test the hypothesis thatdepression of home cage wheel running is a reliable and clinically relevant method to assess migraine painin rats. Adult female rats were implanted with a cannula to inject allyl isothiocyanate (AITC) onto the dura to induce migraine pain, as has been shown before. Rats recovered from implantation surgery for 8 days in cages containing a running wheel. Home cage wheel running was recorded 23 h a day. AITC and the migraine medication sumatriptan were administered in the hour prior to onset of the dark phase. Administration of AITC caused a concentration-dependent decrease in wheel running that lasted 3 h. The duration and magnitude of AITC-induced depression of wheel running was consistent following three repeated injections spaced 48 h apart. Administration of sumatriptan attenuated AITC-induced depressionof wheel running when a large dose (1 mg/kg) was administered immediately following AITC administration. Wheel running patterns did not change when sumatriptan was given to naïve rats. These data indicate that home cage wheel running is a sensitive, reliable, and clinically relevant method to assess migraine pain in the rat.

  9. Diagnosis of prostate cancer via nanotechnological approach

    PubMed Central

    Kang, Benedict J; Jeun, Minhong; Jang, Gun Hyuk; Song, Sang Hoon; Jeong, In Gab; Kim, Choung-Soo; Searson, Peter C; Lee, Kwan Hyi

    2015-01-01

    Prostate cancer is one of the leading causes of cancer-related deaths among the Caucasian adult males in Europe and the USA. Currently available diagnostic strategies for patients with prostate cancer are invasive and unpleasant and have poor accuracy. Many patients have been overly or underly treated resulting in a controversy regarding the reliability of current conventional diagnostic approaches. This review discusses the state-of-the-art research in the development of novel noninvasive prostate cancer diagnostics using nanotechnology coupled with suggested diagnostic strategies for their clinical implication. PMID:26527873

  10. Diagnostic decision-making and strategies to improve diagnosis.

    PubMed

    Thammasitboon, Satid; Cutrer, William B

    2013-10-01

    A significant portion of diagnostic errors arises through cognitive errors resulting from inadequate knowledge, faulty data gathering, and/or faulty verification. Experts estimate that 75% of diagnostic failures can be attributed to clinician diagnostic thinking failure. The cognitive processes that underlie diagnostic thinking of clinicians are complex and intriguing, and it is imperative that clinicians acquire explicit appreciation and application of different cognitive approaches to make decisions better. A dual-process model that unifies many theories of decision-making has emerged as a promising template for understanding how clinicians think and judge efficiently in a diagnostic reasoning process. The identification and implementation of strategies for decreasing or preventing such diagnostic errors has become a growing area of interest and research. Suggested strategies to decrease diagnostic error incidence include increasing clinician's clinical expertise and avoiding inherent cognitive errors to make decisions better. Implementing Interventions focused solely on avoiding errors may work effectively for patient safety issues such as medication errors. Addressing cognitive errors, however, requires equal effort on expanding the individual clinician's expertise. Providing cognitive support to clinicians for robust diagnostic decision-making serves as the final strategic target for decreasing diagnostic errors. Clinical guidelines and algorithms offer another method for streamlining decision-making and decreasing likelihood of cognitive diagnostic errors. Addressing cognitive processing errors is undeniably the most challenging task in reducing diagnostic errors. While many suggested approaches exist, they are mostly based on theories and sciences in cognitive psychology, decision-making, and education. The proposed interventions are primarily suggestions and very few of them have been tested in the actual practice settings. Collaborative research effort is required to effectively address cognitive processing errors. Researchers in various areas, including patient safety/quality improvement, decision-making, and problem solving, must work together to make medical diagnosis more reliable. © 2013 Mosby, Inc. All rights reserved.

  11. Lectin-induced agglutination method of urinary exosomes isolation followed by mi-RNA analysis: Application for prostate cancer diagnostic.

    PubMed

    Samsonov, Roman; Shtam, Tatiana; Burdakov, Vladimir; Glotov, Andrey; Tsyrlina, Evgenia; Berstein, Lev; Nosov, Alexander; Evtushenko, Vladimir; Filatov, Michael; Malek, Anastasia

    2016-01-01

    Prostate cancer is the most common cancer in men. Prostate-specific antigen has, however, insufficient diagnostic specificity. Novel complementary diagnostic approaches are greatly needed. MiRNAs are small regulatory RNAs which play an important role in tumorogenesis and are being investigated as a cancer biomarker. In addition to their intracellular regulatory functions, miRNAs are secreted into the extracellular space and can be found in various body fluids, including urine. The stability of extracellular miRNAs is defined by association with proteins, lipoprotein particles, and membrane vesicles. Among the known forms of miRNA packaging, tumour-derived exosome-enclosed miRNAs is thought to reflect the vital activity of cancer cells. The assessment of the exosomal fraction of urinary miRNA may present a new and highly specific method for prostate cancer diagnostics; however, this is challenged by the absence of reliable and inexpensive methods for isolation of exosomes. Prostate cancer (PC) cell lines and urine samples collected from 35 PC patients and 35 healthy donors were used in the study. Lectins, phytohemagglutinin, and concanavalin A were used to induce agglutination of exosomes. The efficiency of isolation process was evaluated by AFM and DLS assays. The protein content of isolated exosomes was analysed by western blotting. Exosomal RNA was assayed by automated electrophoresis and expression level of selected miRNAs was evaluated by RT-qPCR. The diagnostic potency of the urinary exosomal miRNA assessment was estimated by the ROC method. The formation of multi-vesicular agglutinates in urine can be induced by incubation with lectin at a final concentration of 2 mg/ml. These agglutinates contain urinary exosomes and may be pelleted by centrifugation with a relatively low G-force. The analysis of PC-related miRNA in urinary exosomes revealed significant up-regulation of miR-574-3p, miR-141-5p, and miR-21-5p associated with PC. Lectin-induced aggregation is a low-cost and easily performed method for isolation of exosomes from urine. Isolated exosomes can be further analysed in terms of miRNA content. The miRNA profile of urinary exosomes reflects development of prostate cancer and may present a promising diagnostic tool. © 2015 Wiley Periodicals, Inc.

  12. Spatial recurrence analysis: A sensitive and fast detection tool in digital mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prado, T. L.; Galuzio, P. P.; Lopes, S. R.

    Efficient diagnostics of breast cancer requires fast digital mammographic image processing. Many breast lesions, both benign and malignant, are barely visible to the untrained eye and requires accurate and reliable methods of image processing. We propose a new method of digital mammographic image analysis that meets both needs. It uses the concept of spatial recurrence as the basis of a spatial recurrence quantification analysis, which is the spatial extension of the well-known time recurrence analysis. The recurrence-based quantifiers are able to evidence breast lesions in a way as good as the best standard image processing methods available, but with amore » better control over the spurious fragments in the image.« less

  13. Gene expression information improves reliability of receptor status in breast cancer patients

    PubMed Central

    Kenn, Michael; Schlangen, Karin; Castillo-Tong, Dan Cacsire; Singer, Christian F.; Cibena, Michael; Koelbl, Heinz; Schreiner, Wolfgang

    2017-01-01

    Immunohistochemical (IHC) determination of receptor status in breast cancer patients is frequently inaccurate. Since it directs the choice of systemic therapy, it is essential to increase its reliability. We increase the validity of IHC receptor expression by additionally considering gene expression (GE) measurements. Crisp therapeutic decisions are based on IHC estimates, even if they are borderline reliable. We further improve decision quality by a responsibility function, defining a critical domain for gene expression. Refined normalization is devised to file any newly diagnosed patient into existing data bases. Our approach renders receptor estimates more reliable by identifying patients with questionable receptor status. The approach is also more efficient since the rate of conclusive samples is increased. We have curated and evaluated gene expression data, together with clinical information, from 2880 breast cancer patients. Combining IHC with gene expression information yields a method more reliable and also more efficient as compared to common practice up to now. Several types of possibly suboptimal treatment allocations, based on IHC receptor status alone, are enumerated. A ‘therapy allocation check’ identifies patients possibly miss-classified. Estrogen: false negative 8%, false positive 6%. Progesterone: false negative 14%, false positive 11%. HER2: false negative 2%, false positive 50%. Possible implications are discussed. We propose an ‘expression look-up-plot’, allowing for a significant potential to improve the quality of precision medicine. Methods are developed and exemplified here for breast cancer patients, but they may readily be transferred to diagnostic data relevant for therapeutic decisions in other fields of oncology. PMID:29100391

  14. Proposal for a standardised identification of the mono-exponential terminal phase for orally administered drugs.

    PubMed

    Scheerans, Christian; Derendorf, Hartmut; Kloft, Charlotte

    2008-04-01

    The area under the plasma concentration-time curve from time zero to infinity (AUC(0-inf)) is generally considered to be the most appropriate measure of total drug exposure for bioavailability/bioequivalence studies of orally administered drugs. However, the lack of a standardised method for identifying the mono-exponential terminal phase of the concentration-time curve causes variability for the estimated AUC(0-inf). The present investigation introduces a simple method, called the two times t(max) method (TTT method) to reliably identify the mono-exponential terminal phase in the case of oral administration. The new method was tested by Monte Carlo simulation in Excel and compared with the adjusted r squared algorithm (ARS algorithm) frequently used in pharmacokinetic software programs. Statistical diagnostics of three different scenarios, each with 10,000 hypothetical patients showed that the new method provided unbiased average AUC(0-inf) estimates for orally administered drugs with a monophasic concentration-time curve post maximum concentration. In addition, the TTT method generally provided more precise estimates for AUC(0-inf) compared with the ARS algorithm. It was concluded that the TTT method is a most reasonable tool to be used as a standardised method in pharmacokinetic analysis especially bioequivalence studies to reliably identify the mono-exponential terminal phase for orally administered drugs showing a monophasic concentration-time profile.

  15. Evaluation of the Accelerate Pheno System for Fast Identification and Antimicrobial Susceptibility Testing from Positive Blood Cultures in Bloodstream Infections Caused by Gram-Negative Pathogens.

    PubMed

    Marschal, Matthias; Bachmaier, Johanna; Autenrieth, Ingo; Oberhettinger, Philipp; Willmann, Matthias; Peter, Silke

    2017-07-01

    Bloodstream infections (BSI) are an important cause of morbidity and mortality. Increasing rates of antimicrobial-resistant pathogens limit treatment options, prompting an empirical use of broad-range antibiotics. Fast and reliable diagnostic tools are needed to provide adequate therapy in a timely manner and to enable a de-escalation of treatment. The Accelerate Pheno system (Accelerate Diagnostics, USA) is a fully automated test system that performs both identification and antimicrobial susceptibility testing (AST) directly from positive blood cultures within approximately 7 h. In total, 115 episodes of BSI with Gram-negative bacteria were included in our study and compared to conventional culture-based methods. The Accelerate Pheno system correctly identified 88.7% (102 of 115) of all BSI episodes and 97.1% (102 of 105) of isolates that are covered by the system's identification panel. The Accelerate Pheno system generated an AST result for 91.3% (95 of 104) samples in which the Accelerate Pheno system identified a Gram-negative pathogen. The overall category agreement between the Accelerate Pheno system and culture-based AST was 96.4%, the rates for minor discrepancies 1.4%, major discrepancies 2.3%, and very major discrepancies 1.0%. Of note, ceftriaxone, piperacillin-tazobactam, and carbapenem resistance was correctly detected in blood culture specimens with extended-spectrum beta-lactamase-producing Escherichia coli ( n = 7) and multidrug-resistant Pseudomonas aeruginosa ( n = 3) strains. The utilization of the Accelerate Pheno system reduced the time to result for identification by 27.49 h ( P < 0.0001) and for AST by 40.39 h ( P < 0.0001) compared to culture-based methods in our laboratory setting. In conclusion, the Accelerate Pheno system provided fast, reliable results while significantly improving turnaround time in blood culture diagnostics of Gram-negative BSI. Copyright © 2017 American Society for Microbiology.

  16. Algorithms for optimized maximum entropy and diagnostic tools for analytic continuation.

    PubMed

    Bergeron, Dominic; Tremblay, A-M S

    2016-08-01

    Analytic continuation of numerical data obtained in imaginary time or frequency has become an essential part of many branches of quantum computational physics. It is, however, an ill-conditioned procedure and thus a hard numerical problem. The maximum-entropy approach, based on Bayesian inference, is the most widely used method to tackle that problem. Although the approach is well established and among the most reliable and efficient ones, useful developments of the method and of its implementation are still possible. In addition, while a few free software implementations are available, a well-documented, optimized, general purpose, and user-friendly software dedicated to that specific task is still lacking. Here we analyze all aspects of the implementation that are critical for accuracy and speed and present a highly optimized approach to maximum entropy. Original algorithmic and conceptual contributions include (1) numerical approximations that yield a computational complexity that is almost independent of temperature and spectrum shape (including sharp Drude peaks in broad background, for example) while ensuring quantitative accuracy of the result whenever precision of the data is sufficient, (2) a robust method of choosing the entropy weight α that follows from a simple consistency condition of the approach and the observation that information- and noise-fitting regimes can be identified clearly from the behavior of χ^{2} with respect to α, and (3) several diagnostics to assess the reliability of the result. Benchmarks with test spectral functions of different complexity and an example with an actual physical simulation are presented. Our implementation, which covers most typical cases for fermions, bosons, and response functions, is available as an open source, user-friendly software.

  17. Algorithms for optimized maximum entropy and diagnostic tools for analytic continuation

    NASA Astrophysics Data System (ADS)

    Bergeron, Dominic; Tremblay, A.-M. S.

    2016-08-01

    Analytic continuation of numerical data obtained in imaginary time or frequency has become an essential part of many branches of quantum computational physics. It is, however, an ill-conditioned procedure and thus a hard numerical problem. The maximum-entropy approach, based on Bayesian inference, is the most widely used method to tackle that problem. Although the approach is well established and among the most reliable and efficient ones, useful developments of the method and of its implementation are still possible. In addition, while a few free software implementations are available, a well-documented, optimized, general purpose, and user-friendly software dedicated to that specific task is still lacking. Here we analyze all aspects of the implementation that are critical for accuracy and speed and present a highly optimized approach to maximum entropy. Original algorithmic and conceptual contributions include (1) numerical approximations that yield a computational complexity that is almost independent of temperature and spectrum shape (including sharp Drude peaks in broad background, for example) while ensuring quantitative accuracy of the result whenever precision of the data is sufficient, (2) a robust method of choosing the entropy weight α that follows from a simple consistency condition of the approach and the observation that information- and noise-fitting regimes can be identified clearly from the behavior of χ2 with respect to α , and (3) several diagnostics to assess the reliability of the result. Benchmarks with test spectral functions of different complexity and an example with an actual physical simulation are presented. Our implementation, which covers most typical cases for fermions, bosons, and response functions, is available as an open source, user-friendly software.

  18. Validity and reliability of the minimum basic data set in estimating nosocomial acute gastroenteritis caused by rotavirus.

    PubMed

    Redondo-González, Olga

    2015-03-01

    Rotavirus is the principal cause of nosocomial acute gastroenteritis (NAGE) under 5 years of age. The objectiveis to evaluate the validity and reliability of the minimum basic dataset (MBDS) in estimating the NAGE caused by rotavirus (NAGER) and to analyze any changes during the three years that the Rotarix® and Rotateq® vaccines were used in Spain. A descriptive, retrospectivestudy was carried out in the University Hospital of Guadalajara(UHG) (Spain) between 2003-2009 using the MBDS, positive microbiological results for rotavirus (PMRs), and medical histories.Three methods of estimation were used: 1) An ICD-9-CM code 008.61 in the secondary diagnosis fields (DIAG2) of MBDS; 2) method 1 and/or PMRs with a current or recent hospitalization; and 3) the reference method or method 2 contrasted with patient medical histories. The validity of methods 1 and 2 was determined -sensitivity, specificity, predictive values and likelihood ratios (LRs)-, along with their agreement with method 3 (Kappa coefficient). In addition, the incidence rate ratio between the NAGER rate in 2007-2009 (commercialization period of both vaccines) was calculated with respect to 2003-2005 (precommercialization period). Method 1 identified 65 records with a DIAG2 of 008.61. Method 2 found 62 probable cases, and the reference method, 49 true cases. The sensitivity of the MBDS was 67 %,the positive predictive value was 51 %, and both negative LR (LR-) and reliability were moderate (LR- 0.33, Kappa coefficient 0.58). During 2007-2009, the NARGE decreased by 5 cases per 103 hospitalizations and by 9 per 104 days of hospitalization. Method 2 overestimated both the decline in incidence by 2 per 103 hospitalizations and the decreased risk per day of stay by 10 %. The MBDS found no differences between the two three-year periods, but, like method 2, showed an excellent level of diagnostic evidence (LR+ 67). The MBDS taken together with microbiological results, is more exact, safer and more reliable than the MBDS alone in estimating NAGER; and more useful in ruling out it. Nevertheless, the MBDS alone may be used to estimate and compare such disease in contexts with different prevalences.

  19. Reliability of physical examination for diagnosis of myofascial trigger points: a systematic review of the literature.

    PubMed

    Lucas, Nicholas; Macaskill, Petra; Irwig, Les; Moran, Robert; Bogduk, Nikolai

    2009-01-01

    Trigger points are promoted as an important cause of musculoskeletal pain. There is no accepted reference standard for the diagnosis of trigger points, and data on the reliability of physical examination for trigger points are conflicting. To systematically review the literature on the reliability of physical examination for the diagnosis of trigger points. MEDLINE, EMBASE, and other sources were searched for articles reporting the reliability of physical examination for trigger points. Included studies were evaluated for their quality and applicability, and reliability estimates were extracted and reported. Nine studies were eligible for inclusion. None satisfied all quality and applicability criteria. No study specifically reported reliability for the identification of the location of active trigger points in the muscles of symptomatic participants. Reliability estimates varied widely for each diagnostic sign, for each muscle, and across each study. Reliability estimates were generally higher for subjective signs such as tenderness (kappa range, 0.22-1.0) and pain reproduction (kappa range, 0.57-1.00), and lower for objective signs such as the taut band (kappa range, -0.08-0.75) and local twitch response (kappa range, -0.05-0.57). No study to date has reported the reliability of trigger point diagnosis according to the currently proposed criteria. On the basis of the limited number of studies available, and significant problems with their design, reporting, statistical integrity, and clinical applicability, physical examination cannot currently be recommended as a reliable test for the diagnosis of trigger points. The reliability of trigger point diagnosis needs to be further investigated with studies of high quality that use current diagnostic criteria in clinically relevant patients.

  20. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    PubMed

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (p<0.001). There was no difference between the AUC of conventional ultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  1. [Eppendorf Schizophrenia Inventory (ESI) vs. Frankfurt Complaint Questionnaire (FCQ). Direct comparison in a clinical trial].

    PubMed

    Mass, R

    2005-09-01

    This study is the first to directly compare two clinical questionnaires which are both aimed at self-experienced cognitive dysfunctions of schizophrenia: Eppendorf Schizophrenia Inventory (ESI) and Frankfurt Complaint Questionnaire (FCQ). Evaluated were (a) diagnostic validity, (b) psychometric properties, (c) scale intercorrelations, and (d) factor analytic stability. Ad (a): schizophrenic subjects (n=36) show highly significant increases in the ESI scales and sum score when compared to other clinical groups (patients with depression, alcohol dependence, or obsessive-compulsive disorder, n>30, respectively); on the other hand, the FCQ yields no systematic group differences. Ad (b): mean of reliability coefficients (Cronbach alpha) of the ESI scales is r(tt)=0.86, mean of reliability coefficients of the FCQ scales is significantly lower. Ad (c): the mean intercorrelation between ESI and FCQ scales amounts to r(xy)=0.56 (minimum 0.29, maximum 0.73), corresponding to an average shared variance of about 31%. Ad (d): factor analysis yielded an ESI factor and a FBF factor; one-way ANOVA with the factor scores confirms the diagnostic validity of the ESI. ESI and FCQ measure essentially different aspects of schizophrenic psychopathology. Regarding reliability and diagnostic validity, the ESI is superior to the FCQ.

  2. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems.

    PubMed

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA", which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%" on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples.

  3. Diagnostic and model dependent uncertainty of simulated Tibetan permafrost area

    USGS Publications Warehouse

    Wang, A.; Moore, J.C.; Cui, Xingquan; Ji, D.; Li, Q.; Zhang, N.; Wang, C.; Zhang, S.; Lawrence, D.M.; McGuire, A.D.; Zhang, W.; Delire, C.; Koven, C.; Saito, K.; MacDougall, A.; Burke, E.; Decharme, B.

    2016-01-01

     We perform a land-surface model intercomparison to investigate how the simulation of permafrost area on the Tibetan Plateau (TP) varies among six modern stand-alone land-surface models (CLM4.5, CoLM, ISBA, JULES, LPJ-GUESS, UVic). We also examine the variability in simulated permafrost area and distribution introduced by five different methods of diagnosing permafrost (from modeled monthly ground temperature, mean annual ground and air temperatures, air and surface frost indexes). There is good agreement (99 to 135  ×  104 km2) between the two diagnostic methods based on air temperature which are also consistent with the observation-based estimate of actual permafrost area (101  × 104 km2). However the uncertainty (1 to 128  ×  104 km2) using the three methods that require simulation of ground temperature is much greater. Moreover simulated permafrost distribution on the TP is generally only fair to poor for these three methods (diagnosis of permafrost from monthly, and mean annual ground temperature, and surface frost index), while permafrost distribution using air-temperature-based methods is generally good. Model evaluation at field sites highlights specific problems in process simulations likely related to soil texture specification, vegetation types and snow cover. Models are particularly poor at simulating permafrost distribution using the definition that soil temperature remains at or below 0 °C for 24 consecutive months, which requires reliable simulation of both mean annual ground temperatures and seasonal cycle, and hence is relatively demanding. Although models can produce better permafrost maps using mean annual ground temperature and surface frost index, analysis of simulated soil temperature profiles reveals substantial biases. The current generation of land-surface models need to reduce biases in simulated soil temperature profiles before reliable contemporary permafrost maps and predictions of changes in future permafrost distribution can be made for the Tibetan Plateau.

  4. Diagnostic and model dependent uncertainty of simulated Tibetan permafrost area

    NASA Astrophysics Data System (ADS)

    Wang, W.; Rinke, A.; Moore, J. C.; Cui, X.; Ji, D.; Li, Q.; Zhang, N.; Wang, C.; Zhang, S.; Lawrence, D. M.; McGuire, A. D.; Zhang, W.; Delire, C.; Koven, C.; Saito, K.; MacDougall, A.; Burke, E.; Decharme, B.

    2016-02-01

    We perform a land-surface model intercomparison to investigate how the simulation of permafrost area on the Tibetan Plateau (TP) varies among six modern stand-alone land-surface models (CLM4.5, CoLM, ISBA, JULES, LPJ-GUESS, UVic). We also examine the variability in simulated permafrost area and distribution introduced by five different methods of diagnosing permafrost (from modeled monthly ground temperature, mean annual ground and air temperatures, air and surface frost indexes). There is good agreement (99 to 135 × 104 km2) between the two diagnostic methods based on air temperature which are also consistent with the observation-based estimate of actual permafrost area (101 × 104 km2). However the uncertainty (1 to 128 × 104 km2) using the three methods that require simulation of ground temperature is much greater. Moreover simulated permafrost distribution on the TP is generally only fair to poor for these three methods (diagnosis of permafrost from monthly, and mean annual ground temperature, and surface frost index), while permafrost distribution using air-temperature-based methods is generally good. Model evaluation at field sites highlights specific problems in process simulations likely related to soil texture specification, vegetation types and snow cover. Models are particularly poor at simulating permafrost distribution using the definition that soil temperature remains at or below 0 °C for 24 consecutive months, which requires reliable simulation of both mean annual ground temperatures and seasonal cycle, and hence is relatively demanding. Although models can produce better permafrost maps using mean annual ground temperature and surface frost index, analysis of simulated soil temperature profiles reveals substantial biases. The current generation of land-surface models need to reduce biases in simulated soil temperature profiles before reliable contemporary permafrost maps and predictions of changes in future permafrost distribution can be made for the Tibetan Plateau.

  5. Transition properties of the Be-like Kα X-ray from Mg IX

    NASA Astrophysics Data System (ADS)

    Hu, Feng; Zhang, Shufang; Sun, Yan; Mei, Maofei; Sang, Cuicui; Yang, Jiamin

    2017-12-01

    Energy levels among the lowest 40 fine-structure levels in Be-like Mg IX are calculated using grasp2K code. The wavelengths, oscillator strengths, radiative rates and lifetimes for all possible Kα transitions have been calculated using the multiconfiguration Dirac-Fock method. The accuracy of the results is determined through extensive comparisons with the existing laboratory measurements and theoretical results. The present data can be used reliably for many purposes, such as the line identification of the observed spectra, and modelling and diagnostics of magnesium plasma.

  6. A Rare Case of Pure Erythroid Sarcoma in a Pediatric Patient: Case Report and Literature Review

    PubMed Central

    Tarín, Fabián; Niveiro, María; Tasso, María; Alda, Olga; Verdú, José J.; De Paz, Francisco; López, Silvia; Del Cañizo, María; Such, Esperanza; Barragán, Eva; Martirena, Fernanda

    2017-01-01

    We describe an exceptional case of erythroid sarcoma in a pediatric patient as a growing orbital mass with no evidence of morphologic bone marrow involvement, who was finally diagnosed of pure erythroid sarcoma based on histopathology and flow cytometry criteria. We discuss the contribution of standardized eight-color flow cytometry as a rapid and reliable diagnostic method. The use of normal bone marrow databases allowed us to identify small aberrant populations in bone marrow and later confirm the diagnosis in the neoplastic tissue. PMID:29261159

  7. A Rare Case of Pure Erythroid Sarcoma in a Pediatric Patient: Case Report and Literature Review.

    PubMed

    Manresa, Pablo; Tarín, Fabián; Niveiro, María; Tasso, María; Alda, Olga; López, Francisco; Sarmiento, Héctor; Verdú, José J; De Paz, Francisco; López, Silvia; Del Cañizo, María; Such, Esperanza; Barragán, Eva; Martirena, Fernanda

    2017-12-20

    We describe an exceptional case of erythroid sarcoma in a pediatric patient as a growing orbital mass with no evidence of morphologic bone marrow involvement, who was finally diagnosed of pure erythroid sarcoma based on histopathology and flow cytometry criteria. We discuss the contribution of standardized eight-color flow cytometry as a rapid and reliable diagnostic method. The use of normal bone marrow databases allowed us to identify small aberrant populations in bone marrow and later confirm the diagnosis in the neoplastic tissue.

  8. The Challenges and Advances in Diagnosis of Vector-Borne Diseases: Where Do We Stand?

    PubMed

    Kuleš, Josipa; Potocnakova, Lenka; Bhide, Katarina; Tomassone, Laura; Fuehrer, Hans-Peter; Horvatić, Anita; Galan, Asier; Guillemin, Nicolas; Nižić, Petra; Mrljak, Vladimir; Bhide, Mangesh

    2017-05-01

    Vector-borne diseases (VBD) are of major importance to human and animal health. In recent years, VBD have been emerging or re-emerging in many geographical areas, alarming new disease threats and economic losses. The precise diagnosis of many of these diseases still remains a major challenge because of the lack of comprehensive data available on accurate and reliable diagnostic methods. Here, we conducted a systematic and in-depth review of the former, current, and upcoming techniques employed for the diagnosis of VBD.

  9. The Self-Perception and Usage of Medical Apps amongst Medical Students in the United States: A Cross-Sectional Survey.

    PubMed

    Quant, Cara; Altieri, Lisa; Torres, Juan; Craft, Noah

    2016-01-01

    Background. Mobile medical software applications (apps) are used for clinical decision-making at the point of care. Objectives. To determine (1) the usage, reliability, and popularity of mobile medical apps and (2) medical students' perceptions of app usage effect on the quality of patient-provider interaction in healthcare settings. Methods. An anonymous web-based survey was distributed to medical students. Frequency of use, type of app used, and perceptions of reliability were assessed via univariate analysis. Results. Seven hundred thirty-one medical students responded, equating to a response rate of 29%. The majority (90%) of participants thought that medical apps enhance clinical knowledge, and 61% said that medical apps are as reliable as textbooks. While students thought that medical apps save time, improve the care of their patients, and improve diagnostic accuracy, 53% of participants believed that mobile device use in front of colleagues and patients makes one appear less competent. Conclusion. While medical students believe in the utility and reliability of medical apps, they were hesitant to use them out of fear of appearing less engaged. Higher levels of training correlated with a greater degree of comfort when using medical apps in front of patients.

  10. [Diagnostic reliability and incidence of genital mycoses in pregnant women].

    PubMed

    Martius, J; Hartmann, A A

    1983-01-01

    Smears were taken from the anterior and posterior vaginal fornices of 232 women who attended prenatal consultations at Würzburg University Gynecological Clinic. The cultures were compared using Sabouraud's Glucose Agar (S.G.A.) and two commercially available rapid testing media--Nickerson Medium (N.M.) and Microstix Candida (M.C.T.) for saccharomycetes. The presence of saccharomycetes was demonstrated by means of S.G.A. in 23% (52) of the women and with N.M. in 10% (23). If only N.M. had been used, colonization by saccharomycetes would have been overlooked in 32 cases. With regard to the reliability of identification of saccharomycetes in the group, there was no significant difference between N.M. and M.C.T. In women without Candidiasis, negative findings with N.M. and M.C.T. were in agreement in 96% of the cases. Reliable identification of saccharomycetes in genital and gastro-intestinal areas is of special importance in prenatal examinations in view of the risk of infection of the newborn. The investigation reported in the present paper indicates that such reliability can only be achieved with the more costly culture method using Sabouraud's Glucose Agar.

  11. [Diagnostic rentability of close pleural biopsy: Tru-cut vs. Cope].

    PubMed

    Valdez-López, Héctor Glenn; Cano-Rodríguez, Alma Iris; Montemayor-Chapa, Mario; Castillo-Sánchez, Juan Francisco

    2018-01-01

    The prevalence of pleural effusion in Mexico is over 400 per 100 000 inhabitants. The etiology is infectious in 45.7% and neoplastic in 32.6%. Closed pleural biopsy sensibility is 48-70% in cancer and 50-59% in tuberculosis using Cope or Abrams needle. In 1989, Tru-cut needle biopsy was described in a small study for massive pleural effusions with a sensibility of 86%. Our Institute has a wide experience with this infrequently procedure with reliable results than using Cope needle. Diagnostic yield should be evaluated. We aimed to evaluate the diagnostic yield of Tru-cut vs. standard Cope biopsy in the histopathological diagnosis of pleural effusion. Experimental, not blinded, analytical, cross-sectional study. We studied 44 patients (24 male and 20 female) with exudative pleural effusion over a period of 14 months. Every patient underwent four Tru-cut and four Cope needle biopsies. The diagnostic yield of both methods was compared. The mean age of patients was 61.4 ± 12.2 years. The diagnosis was achieved in 25 (57%) of patients using Tru-cut and 22 (50%) of patients using Cope's closed pleural biopsy. The diagnostic value was not significantly higher (p = 0.41). The most common diagnoses were adenocarcinoma (20.5%), mesothelioma (15.9%) and tuberculosis (15.9%). The diagnostic yield of Tru-cut needle biopsy is slightly higher than Cope pleural biopsy, very similar to that reported previously. The experience in this procedure is an advantage in our clinical practice.

  12. Diagnostic reliability of 3.0-T MRI for detecting osseous abnormalities of the temporomandibular joint.

    PubMed

    Sawada, Kunihiko; Amemiya, Toshihiko; Hirai, Shigenori; Hayashi, Yusuke; Suzuki, Toshihiro; Honda, Masahiko; Sisounthone, Johnny; Matsumoto, Kunihito; Honda, Kazuya

    2018-01-01

    We compared the diagnostic reliability of 3.0-T magnetic resonance imaging (MRI) for detection of osseous abnormalities of the temporomandibular joint (TMJ) with that of the gold standard, cone-beam computed tomography (CBCT). Fifty-six TMJs were imaged with CBCT and MRI, and images of condyles and fossae were independently assessed for the presence of osseous abnormalities. The accuracy, sensitivity, and specificity of 3.0-T MRI were 0.88, 1.0, and 0.73, respectively, in condyle evaluation and 0.91, 0.75, and 0.95 in fossa evaluation. The McNemar test showed no significant difference (P > 0.05) between MRI and CBCT in the evaluation of osseous abnormalities in condyles and fossae. The present results indicate that 3.0-T MRI is equal to CBCT in the diagnostic evaluation of osseous abnormalities of the mandibular condyle.

  13. What is a reflex? A guide for understanding disorders of consciousness.

    PubMed

    Fischer, David B; Truog, Robert D

    2015-08-11

    Uncertainty in diagnosing disorders of consciousness, and specifically in determining whether consciousness has been lost or retained, poses challenging scientific and ethical questions. Recent neuroimaging-based tests for consciousness have cast doubt on the reliability of behavioral criteria in assessing states of consciousness and generate new questions about the assumptions used in formulating coherent diagnostic criteria. The reflex, a foundational diagnostic tool, offers unique insight into these disorders; behaviors produced by unconscious patients are thought to be purely reflexive, whereas those produced by conscious patients can be volitional. Further investigation, however, reveals that reflexes cannot be reliably distinguished from conscious behaviors on the basis of any generalizable empirical characteristics. Ambiguity between reflexive and conscious behaviors undermines the capacity of the reflex to distinguish between disorders of consciousness and has implications for how these disorders should be conceptualized in future diagnostic criteria. © 2015 American Academy of Neurology.

  14. The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R): a scale to assist the diagnosis of Autism Spectrum Disorder in adults: an international validation study.

    PubMed

    Ritvo, Riva Ariella; Ritvo, Edward R; Guthrie, Donald; Ritvo, Max J; Hufnagel, Demetra H; McMahon, William; Tonge, Bruce; Mataix-Cols, David; Jassi, Amita; Attwood, Tony; Eloff, Johann

    2011-08-01

    The Ritvo Autism Asperger Diagnostic Scale-Revised (RAADS-R) is a valid and reliable instrument to assist the diagnosis of adults with Autism Spectrum Disorders (ASD). The 80-question scale was administered to 779 subjects (201 ASD and 578 comparisons). All ASD subjects met inclusion criteria: DSM-IV-TR, ADI/ADOS diagnoses and standardized IQ testing. Mean scores for each of the questions and total mean ASD vs. the comparison groups' scores were significantly different (p < .0001). Concurrent validity with Constantino Social Responsiveness Scale-Adult = 95.59%. Sensitivity = 97%, specificity = 100%, test-retest reliability r = .987. Cronbach alpha coefficients for the subscales and 4 derived factors were good. We conclude that the RAADS-R is a useful adjunct diagnostic tool for adults with ASD.

  15. Radiometry in medicine and biology

    NASA Astrophysics Data System (ADS)

    Nahm, Kie-Bong; Choi, Eui Y.

    2012-10-01

    Diagnostics in medicine plays a critical role in helping medical professionals deliver proper diagnostic decisions. Most samples in this trade are of the human origin and a great portion of methodologies practiced in biology labs is shared in clinical diagnostic laboratories as well. Most clinical tests are quantitative in nature and recent increase in interests in preventive medicine requires the determination of minimal concentration of target analyte: they exist in small quantities at the early stage of various diseases. Radiometry or the use of optical radiation is the most trusted and reliable means of converting biologic concentrations into quantitative physical quantities. Since optical energy is readily available in varying energies (or wavelengths), the appropriate combination of light and the sample absorption properties provides reliable information about the sample concentration through Beer-Lambert law to a decent precision. In this article, the commonly practiced techniques in clinical and biology labs are reviewed from the standpoint of radiometry.

  16. Validation of Digital Microscopy Compared With Light Microscopy for the Diagnosis of Canine Cutaneous Tumors.

    PubMed

    Bertram, Christof A; Gurtner, Corinne; Dettwiler, Martina; Kershaw, Olivia; Dietert, Kristina; Pieper, Laura; Pischon, Hannah; Gruber, Achim D; Klopfleisch, Robert

    2018-07-01

    Integration of new technologies, such as digital microscopy, into a highly standardized laboratory routine requires the validation of its performance in terms of reliability, specificity, and sensitivity. However, a validation study of digital microscopy is currently lacking in veterinary pathology. The aim of the current study was to validate the usability of digital microscopy in terms of diagnostic accuracy, speed, and confidence for diagnosing and differentiating common canine cutaneous tumor types and to compare it to classical light microscopy. Therefore, 80 histologic sections including 17 different skin tumor types were examined twice as glass slides and twice as digital whole-slide images by 6 pathologists with different levels of experience at 4 time points. Comparison of both methods found digital microscopy to be noninferior for differentiating individual tumor types within the category epithelial and mesenchymal tumors, but diagnostic concordance was slightly lower for differentiating individual round cell tumor types by digital microscopy. In addition, digital microscopy was associated with significantly shorter diagnostic time, but diagnostic confidence was lower and technical quality was considered inferior for whole-slide images compared with glass slides. Of note, diagnostic performance for whole-slide images scanned at 200× magnification was noninferior in diagnostic performance for slides scanned at 400×. In conclusion, digital microscopy differs only minimally from light microscopy in few aspects of diagnostic performance and overall appears adequate for the diagnosis of individual canine cutaneous tumors with minor limitations for differentiating individual round cell tumor types and grading of mast cell tumors.

  17. An evidence-based approach to assessing surgical versus clinical diagnosis of symptomatic endometriosis.

    PubMed

    Taylor, Hugh S; Adamson, G David; Diamond, Michael P; Goldstein, Steven R; Horne, Andrew W; Missmer, Stacey A; Snabes, Michael C; Surrey, Eric; Taylor, Robert N

    2018-05-05

    Challenges intrinsic to the accurate diagnosis of endometriosis contribute to an extended delay between the onset of symptoms and clinical confirmation. Intraoperative visualization, preferably with histologic verification, is considered by many professional organizations to be the gold standard by which endometriosis is diagnosed. Clinical diagnosis of symptomatic endometriosis via patient history, physical examination, and noninvasive tests, though more easily executed, is generally viewed as less accurate than surgical diagnosis. Technological advances and increased understanding of the pathophysiology of endometriosis warrant continuing reevaluation of the standard method for diagnosing symptomatic disease. A review of the published literature was therefore performed with the goal of comparing the accuracy of clinical diagnostic measures with that of surgical diagnosis. The current body of evidence suggests that clinical diagnosis of symptomatic endometriosis is more reliable than previously recognized and that surgical diagnosis has limitations that could be underappreciated. Regardless of the methodology used, women with suspected symptomatic endometriosis would be well served by a diagnostic paradigm that is reliable, conveys minimal risk of under- or over-diagnosis, lessens the time from symptom development to diagnosis, and guides the appropriate use of medical and surgical management strategies. © 2018 The Authors. International Journal of Gynecology & Obstetrics published by John Wiley & Sons Ltd on behalf of International Federation of Gynecology and Obstetrics.

  18. Genital Ulcer Disease: How Worrisome Is It Today? A Status Report from New Delhi, India

    PubMed Central

    Muralidhar, Sumathi; Talwar, Richa; Anil Kumar, Deepa; Kumar, Joginder; Bala, Manju; Khan, Nilofar; Ramesh, V.

    2013-01-01

    Background and Objectives. Genital ulcer diseases represent a diagnostic dilemma, especially in India, where few STI clinics have access to reliable laboratory facility. The changing STI trends require that a correct diagnosis be made in order to institute appropriate treatment and formulate control policies. The objective of this study was to determine recent trends in aetiology of genital ulcers, by using accurate diagnostic tools. Methods. Specimens from 90 ulcer patients were processed for dark field microscopy, stained smears, culture for H. ducreyi, and real-time PCR. Blood samples were collected for serological tests. Results. Prevalence of GUD was 7.45 with mean age at initial sexual experience as 19.2 years. Use of condom with regular and nonregular partners was 19.5% and 42.1%, respectively. Sexual orientation was heterosexual (92.2%) or homosexual (2.2%). There were 8 cases positive for HIV (8.9%). Herpes simplex virus ulcers were the commonest, followed by syphilis and chancroid. There were no cases of donovanosis and LGV. Conclusions. A valuable contribution of this study was in validating clinical and syndromic diagnoses of genital ulcers with an accurate aetiological diagnosis. Such reliable data will aid treatment and better define control measures of common agents and help eliminate diseases amenable to elimination, like donovanosis. PMID:26316954

  19. RAMAN spectroscopy imaging improves the diagnosis of papillary thyroid carcinoma

    NASA Astrophysics Data System (ADS)

    Rau, Julietta V.; Graziani, Valerio; Fosca, Marco; Taffon, Chiara; Rocchia, Massimiliano; Crucitti, Pierfilippo; Pozzilli, Paolo; Onetti Muda, Andrea; Caricato, Marco; Crescenzi, Anna

    2016-10-01

    Recent investigations strongly suggest that Raman spectroscopy (RS) can be used as a clinical tool in cancer diagnosis to improve diagnostic accuracy. In this study, we evaluated the efficiency of Raman imaging microscopy to discriminate between healthy and neoplastic thyroid tissue, by analyzing main variants of Papillary Thyroid Carcinoma (PTC), the most common type of thyroid cancer. We performed Raman imaging of large tissue areas (from 100 × 100 μm2 up to 1 × 1 mm2), collecting 38 maps containing about 9000 Raman spectra. Multivariate statistical methods, including Linear Discriminant Analysis (LDA), were applied to translate Raman spectra differences between healthy and PTC tissues into diagnostically useful information for a reliable tissue classification. Our study is the first demonstration of specific biochemical features of the PTC profile, characterized by significant presence of carotenoids with respect to the healthy tissue. Moreover, this is the first evidence of Raman spectra differentiation between classical and follicular variant of PTC, discriminated by LDA with high efficiency. The combined histological and Raman microscopy analyses allow clear-cut integration of morphological and biochemical observations, with dramatic improvement of efficiency and reliability in the differential diagnosis of neoplastic thyroid nodules, paving the way to integrative findings for tumorigenesis and novel therapeutic strategies.

  20. Neuroleptic-induced movement disorders in a naturalistic schizophrenia population: diagnostic value of actometric movement patterns.

    PubMed

    Janno, Sven; Holi, Matti M; Tuisku, Katinka; Wahlbeck, Kristian

    2008-04-18

    Neuroleptic-induced movement disorders (NIMDs) have overlapping co-morbidity. Earlier studies have described typical clinical movement patterns for individual NIMDs. This study aimed to identify specific movement patterns for each individual NIMD using actometry. A naturalistic population of 99 schizophrenia inpatients using conventional antipsychotics and clozapine was evaluated. Subjects with NIMDs were categorized using the criteria for NIMD found in the Diagnostic and Statistical Manual for Mental Disorders - Fourth Edition (DSM-IV).Two blinded raters evaluated the actometric-controlled rest activity data for activity periods, rhythmical activity, frequencies, and highest acceleration peaks. A simple subjective question was formulated to test patient-based evaluation of NIMD. The patterns of neuroleptic-induced akathisia (NIA) and pseudoakathisia (PsA) were identifiable in actometry with excellent inter-rater reliability. The answers to the subjective question about troubles with movements distinguished NIA patients from other patients rather well. Also actometry had rather good screening performances in distinguishing akathisia from other NIMD. Actometry was not able to reliably detect patterns of neuroleptic-induced parkinsonism and tardive dyskinesia. The present study showed that pooled NIA and PsA patients had a different pattern in lower limb descriptive actometry than other patients in a non-selected sample. Careful questioning of patients is a useful method of diagnosing NIA in a clinical setting.

  1. Development of an indirect ELISA based on the recombinant Spm2 protein for detection of tropical theileriosis.

    PubMed

    Tian, Zhancheng; Du, Xiaoyue; Du, Junzheng; Gao, Shandian; Yu, Ruiming; Hassan, Muhammad Adeel; Liu, Guangyuan; Luo, Jianxun; Yin, Hong

    2018-06-01

    Tropical theileriosis, caused by Theileria annulata, is distributed worldwide and causes great economic losses in dairy. The reliable diagnostic method is critical for prevention and control of the disease. In this study, a sporozoite and macroschizont gene 2 (spm2) protein from T. annulata was used to develop an indirect ELISA for tropical theileriosis. Specificity test showed that there were no cross-reactions with antibodies raised against other bovine piroplasm species using ELISA or western blotting. The specificity and sensitivity were 98.4% and 98.7%, respectively, with a threshold of 35.5% of the specific mean antibody rate (AbR). Furthermore, a total of 196 field sera samples collected from Xinjiang and Gansu provinces were detected by the spm2 ELISA and IFA. The results obtained with the spm2 ELISA and IFA in this study had the moderate agreement. The average positive rates of T. annulata sera samples detected in the present study were close to the prevalence of previous reports in these endemic areas. This indicated that the Spm2 ELISA could be used as a reliable diagnostic tool for serological survey of T. annulata infection in areas where Theileria parva is not present. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Efficiency of the Bethesda System for Thyroid Cytopathology.

    PubMed

    Mora-Guzmán, Ismael; Muñoz de Nova, José Luis; Marín-Campos, Cristina; Jiménez-Heffernan, José Antonio; Cuesta Pérez, Juan Julián; Lahera Vargas, Marcos; Torres Mínguez, Emma; Martín-Pérez, Elena

    2018-03-28

    Fine-needle aspiration biopsies are a key tool for preoperative assessment of thyroid nodules, and the Bethesda system is the preferred method to report cytological analysis. The purpose of this study is to assess the efficiency of the Bethesda system to identify the malignancy risk of thyroid nodules. Patients who underwent thyroid surgery between June 2010 and June 2017 were included. Samples were classified into 6categories according to rates of malignancy associated with each diagnostic category. In order to investigate the correlation between categories, a statistical analysis compared the categories with pathology reports. Diagnostic indicators were calculated as a screening test (categories IV, V, VI as true-positive) and as a method to identify malignancy (V, VI as true-positive). In a series of 522 patients, we found 184 (35.2%) malignant tumours, papillary carcinoma being the most prevalent with 155 cases (84.2%). Malignant rates for diagnostic categories were: I, 0%; II, 1.5%; III, 6.4%; IV, 31%; V, 86.5%; VI, 100%. A robust correlation was identified between categories on statistical analysis. For the «screening test» analysis, sensitivity was 98.9%, specificity 84.4%, positive predictive value 69.6%, negative predictive value 99.5%, and diagnostic accuracy 88.2%. Analysing the accuracy to detect malignancy, values were: sensitivity 98.6%, specificity 97.6%, positive predictive value 93.5%, negative predictive value 99.5%, diagnostic accuracy 97.9%. The Bethesda system is a clear and reliable approach to report thyroid cytology and therefore is an effective tool to identify malignancy risk and guide clinical management. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. A diagnostic approach in Alzheimer`s disease using three-dimensional stereotactic surface projections of Fluorine-18-FDG PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minoshima, S.; Frey, K.A.; Koeppe, R.A.

    1995-07-01

    To improve the diagnostic performance of PET as an aid in evaluating patients suspected of having Alzheimer`s disease, the authors developed a fully automated method which generates comprehensive image presentations and objective diagnostic indices. Fluorine-18-fluorodeoxyglucose PET image sets were collected from 37 patients with probable Alzheimer`s disease (including questionable and mild dementia), 22 normal subjects and 5 patients with cerebrovascular disease. Following stereotactic anatomic standardization, metabolic activity on an individual`s PET image set was extracted to a set of predefined surface pixels (three-dimensional stereotactic surface projection, 3D-SSP), which was used in the subsequent analysis. A normal database was created bymore » averaging extracted datasets of the normal subjects. Patients` datasets were compared individually with the normal database by calculating a Z-score on a pixel-by-pixel basis and were displayed in 3D-SSP views for visual inspections. Diagnostic indices were then generated based on averaged Z-scores for the association cortices. Patterns and severities of metabolic reduction in patients with probable Alzheimer`s disease were seen in the standard 3D-SSP views of extracted raw data and statistical Z-scores. When discriminating patients with probable Alzheimer`s disease from normal subjects, diagnostic indices of the parietal association cortex and unilaterally averaged parietal-temporal-frontal cortex showed sensitivities of 95% and 97%, respectively, with a specificity of 100%. Neither index yielded false-positive results for cerebrovascular disease. 3D-SSP enables quantitative data extraction and reliable localization of metabolic abnormalities by means of stereotactic coordinates. The proposed method is a promising approach for interpreting functional brain PET scans. 45 refs., 5 figs.« less

  4. Magnetic Resonance Angiography in the Diagnosis of Cerebral Arteriovenous Malformation and Dural Arteriovenous Fistulas: Comparison of Time-Resolved Magnetic Resonance Angiography and Three Dimensional Time-of-Flight Magnetic Resonance Angiography

    PubMed Central

    Cheng, Yu-Ching; Chen, Hung-Chieh; Wu, Chen-Hao; Wu, Yi-Ying; Sun, Ming-His; Chen, Wen-Hsien; Chai, Jyh-Wen; Chi-Chang Chen, Clayton

    2016-01-01

    Background Traditional digital subtraction angiography (DSA) is currently the gold standard diagnostic method for the diagnosis and evaluation of cerebral arteriovenous malformation (AVM) and dural arteriovenous fistulas (dAVF). Objectives The aim of this study was to analyze different less invasive magnetic resonance angiography (MRA) images, time-resolved MRA (TR-MRA) and three-dimensional time-of-flight MRA (3D TOF MRA) to identify their diagnostic accuracy and to determine which approach is most similar to DSA. Patients and Methods A total of 41 patients with AVM and dAVF at their initial evaluation or follow-up after treatment were recruited in this study. We applied time-resolved angiography using keyhole (4D-TRAK) MRA to perform TR-MRA and 3D TOF MRA examinations simultaneously followed by DSA, which was considered as a standard reference. Two experienced neuroradiologists reviewed the images to compare the diagnostic accuracy, arterial feeder and venous drainage between these two MRA images. Inter-observer agreement for different MRA images was assessed by Kappa coefficient and the differences of diagnostic accuracy between MRA images were evaluated by the Wilcoxon rank sum test. Results Almost all vascular lesions (92.68%) were correctly diagnosed using 4D-TRAK MRA. However, 3D TOF MRA only diagnosed 26 patients (63.41%) accurately. There were statistically significant differences regarding lesion diagnostic accuracy (P = 0.008) and venous drainage identification (P < 0.0001) between 4D-TRAK MRA and 3D TOF MRA. The results indicate that 4D-TRAK MRA is superior to 3D TOF MRA in the assessment of lesions. Conclusion Compared with 3D TOF MRA, 4D-TRAK MRA proved to be a more reliable screening modality and follow-up method for the diagnosis of cerebral AVM and dAVF. PMID:27679690

  5. Management of uncomplicated malaria in febrile under five-year-old children by community health workers in Madagascar: reliability of malaria rapid diagnostic tests

    PubMed Central

    2012-01-01

    Background Early diagnosis, as well as prompt and effective treatment of uncomplicated malaria, are essential components of the anti-malaria strategy in Madagascar to prevent severe malaria, reduce mortality and limit malaria transmission. The purpose of this study was to assess the performance of the malaria rapid diagnostic tests (RDTs) used by community health workers (CHWs) by comparing RDT results with two reference methods (microscopy and Polymerase Chain Reaction, PCR). Methods Eight CHWs in two districts, each with a different level of endemic malaria transmission, were trained to use RDTs in the management of febrile children under five years of age. RDTs were performed by CHWs in all febrile children who consulted for fever. In parallel, retrospective parasitological diagnoses were made by microscopy and PCR. The results of these different diagnostic methods were analysed to evaluate the diagnostic performance of the RDTs administered by the CHWs. The stability of the RDTs stored by CHWs was also evaluated. Results Among 190 febrile children with suspected malaria who visited CHWs between February 2009 and February 2010, 89.5% were found to be positive for malaria parasites by PCR, 51.6% were positive by microscopy and 55.8% were positive by RDT. The performance accuracy of the RDTs used by CHWs in terms of sensitivity, specificity, positive and negative predictive values was greater than 85%. Concordance between microscopy and RDT, estimated by the Kappa value was 0.83 (95% CI: 0.75-0.91). RDTs stored by CHWs for 24 months were capable of detecting Plasmodium falciparum in blood at a level of 200 parasites/μl. Conclusion Introduction of easy-to-use diagnostic tools, such as RDTs, at the community level appears to be an effective strategy for improving febrile patient management and for reducing excessive use of anti-malarial drugs. PMID:22443344

  6. Measurement of compartment elasticity using pressure related ultrasound: a method to identify patients with potential compartment syndrome.

    PubMed

    Sellei, R M; Hingmann, S J; Kobbe, P; Weber, C; Grice, J E; Zimmerman, F; Jeromin, S; Gansslen, A; Hildebrand, F; Pape, H C

    2015-01-01

    PURPOSE OF THE STUDY Decision-making in treatment of an acute compartment syndrome is based on clinical assessment, supported by invasive monitoring. Thus, evolving compartment syndrome may require repeated pressure measurements. In suspected cases of potential compartment syndromes clinical assessment alone seems to be unreliable. The objective of this study was to investigate the feasibility of a non-invasive application estimating whole compartmental elasticity by ultrasound, which may improve accuracy of diagnostics. MATERIAL AND METHODS In an in-vitro model, using an artificial container simulating dimensions of the human anterior tibial compartment, intracompartmental pressures (p) were raised subsequently up to 80 mm Hg by infusion of saline solution. The compartmental depth (mm) in the cross-section view was measured before and after manual probe compression (100 mm Hg) upon the surface resulting in a linear compartmental displacement (Δd). This was repeated at rising compartmental pressures. The resulting displacements were related to the corresponding intra-compartmental pressures simulated in our model. A hypothesized relationship between pressures related compartmental displacement and the elasticity at elevated compartment pressures was investigated. RESULTS With rising compartmental pressures, a non-linear, reciprocal proportional relation between the displacement (mm) and the intra-compartmental pressure (mm Hg) occurred. The Pearson's coefficient showed a high correlation (r2 = -0.960). The intraobserver reliability value kappa resulted in a statistically high reliability (κ = 0.840). The inter-observer value indicated a fair reliability (κ = 0.640). CONCLUSIONS Our model reveals that a strong correlation between compartmental strain displacements assessed by ultrasound and the intra-compartmental pressure changes occurs. Further studies are required to prove whether this assessment is transferable to human muscle tissue. Determining the complete compartmental elasticity by ultrasound enhancement, this application may improve detection of early signs of potential compartment syndrome. Key words: compartment syndrome, intra-compartmental pressure, non-invasive diagnostic, elasticity measurement, elastography.

  7. Method of detecting genetic translocations identified with chromosomal abnormalities

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas

    2001-01-01

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  8. Method of detecting genetic deletions identified with chromosomal abnormalities

    DOEpatents

    Gray, Joe W; Pinkel, Daniel; Tkachuk, Douglas

    2013-11-26

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acids probes are typically of a complexity greater tha 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particlularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar ut genetically different diseases, and for many prognostic and diagnostic applications.

  9. Quantifying two-dimensional nonstationary signal with power-law correlations by detrended fluctuation analysis

    NASA Astrophysics Data System (ADS)

    Fan, Qingju; Wu, Yonghong

    2015-08-01

    In this paper, we develop a new method for the multifractal characterization of two-dimensional nonstationary signal, which is based on the detrended fluctuation analysis (DFA). By applying to two artificially generated signals of two-component ARFIMA process and binomial multifractal model, we show that the new method can reliably determine the multifractal scaling behavior of two-dimensional signal. We also illustrate the applications of this method in finance and physiology. The analyzing results exhibit that the two-dimensional signals under investigation are power-law correlations, and the electricity market consists of electricity price and trading volume is multifractal, while the two-dimensional EEG signal in sleep recorded for a single patient is weak multifractal. The new method based on the detrended fluctuation analysis may add diagnostic power to existing statistical methods.

  10. Using meta-analysis to inform the design of subsequent studies of diagnostic test accuracy.

    PubMed

    Hinchliffe, Sally R; Crowther, Michael J; Phillips, Robert S; Sutton, Alex J

    2013-06-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial evidence to underpin reliable clinical decision-making. Very few investigators consider any sample size calculations when designing a new diagnostic accuracy study. However, it is important to consider the number of subjects in a new study in order to achieve a precise measure of accuracy. Sutton et al. have suggested previously that when designing a new therapeutic trial, it could be more beneficial to consider the power of the updated meta-analysis including the new trial rather than of the new trial itself. The methodology involves simulating new studies for a range of sample sizes and estimating the power of the updated meta-analysis with each new study added. Plotting the power values against the range of sample sizes allows the clinician to make an informed decision about the sample size of a new trial. This paper extends this approach from the trial setting and applies it to diagnostic accuracy studies. Several meta-analytic models are considered including bivariate random effects meta-analysis that models the correlation between sensitivity and specificity. Copyright © 2012 John Wiley & Sons, Ltd. Copyright © 2012 John Wiley & Sons, Ltd.

  11. TOCUSO: Test of Conceptual Understanding on High School Optics Topics

    ERIC Educational Resources Information Center

    Akarsu, Bayram

    2012-01-01

    Physics educators around the world often need reliable diagnostic materials to measure students' understanding of physics concept in high school. The purpose of this study is to evaluate a new diagnostic tool on High School Optics concept. Test of Conceptual Understanding on High School Optics (TOCUSO) consists of 25 conceptual items that measures…

  12. The Effects of Q-Matrix Design on Classification Accuracy in the Log-Linear Cognitive Diagnosis Model

    ERIC Educational Resources Information Center

    Madison, Matthew J.; Bradshaw, Laine P.

    2015-01-01

    Diagnostic classification models are psychometric models that aim to classify examinees according to their mastery or non-mastery of specified latent characteristics. These models are well-suited for providing diagnostic feedback on educational assessments because of their practical efficiency and increased reliability when compared with other…

  13. Attribute-Level and Pattern-Level Classification Consistency and Accuracy Indices for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Wang, Wenyi; Song, Lihong; Chen, Ping; Meng, Yaru; Ding, Shuliang

    2015-01-01

    Classification consistency and accuracy are viewed as important indicators for evaluating the reliability and validity of classification results in cognitive diagnostic assessment (CDA). Pattern-level classification consistency and accuracy indices were introduced by Cui, Gierl, and Chang. However, the indices at the attribute level have not yet…

  14. An Interview with Medical Diagnostics Scientist Bernhard Weigl

    ERIC Educational Resources Information Center

    Sullivan, Megan

    2010-01-01

    Medical diagnostics help us evaluate a range of disorders, such as cancer and infectious diseases. In the United States and other developed countries, doctors have access to advanced equipment and laboratories that provide reliable diagnoses. As a result, when we are sick, we feel confident that we will get the treatment we need. Unfortunately,…

  15. The Application of Strength of Association Statistics to the Item Analysis of an In-Training Examination in Diagnostic Radiology.

    ERIC Educational Resources Information Center

    Diamond, James J.; McCormick, Janet

    1986-01-01

    Using item responses from an in-training examination in diagnostic radiology, the application of a strength of association statistic to the general problem of item analysis is illustrated. Criteria for item selection, general issues of reliability, and error of measurement are discussed. (Author/LMO)

  16. Electrochemistry-based Approaches to Low Cost, High Sensitivity, Automated, Multiplexed Protein Immunoassays for Cancer Diagnostics

    PubMed Central

    Dixit, Chandra K.; Kadimisetty, Karteek; Otieno, Brunah A.; Tang, Chi; Malla, Spundana; Krause, Colleen E.; Rusling, James F.

    2015-01-01

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. Simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that doesn’t require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for highly sensitive detection of the panel of cancer-specific biomarkers with high specificity and at the same time have the potential to be translated into a POC. PMID:26525998

  17. Electrochemistry-based approaches to low cost, high sensitivity, automated, multiplexed protein immunoassays for cancer diagnostics.

    PubMed

    Dixit, Chandra K; Kadimisetty, Karteek; Otieno, Brunah A; Tang, Chi; Malla, Spundana; Krause, Colleen E; Rusling, James F

    2016-01-21

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.

  18. Spectral areas and ratios classifier algorithm for pancreatic tissue classification using optical spectroscopy

    NASA Astrophysics Data System (ADS)

    Chandra, Malavika; Scheiman, James; Simeone, Diane; McKenna, Barbara; Purdy, Julianne; Mycek, Mary-Ann

    2010-01-01

    Pancreatic adenocarcinoma is one of the leading causes of cancer death, in part because of the inability of current diagnostic methods to reliably detect early-stage disease. We present the first assessment of the diagnostic accuracy of algorithms developed for pancreatic tissue classification using data from fiber optic probe-based bimodal optical spectroscopy, a real-time approach that would be compatible with minimally invasive diagnostic procedures for early cancer detection in the pancreas. A total of 96 fluorescence and 96 reflectance spectra are considered from 50 freshly excised tissue sites-including human pancreatic adenocarcinoma, chronic pancreatitis (inflammation), and normal tissues-on nine patients. Classification algorithms using linear discriminant analysis are developed to distinguish among tissues, and leave-one-out cross-validation is employed to assess the classifiers' performance. The spectral areas and ratios classifier (SpARC) algorithm employs a combination of reflectance and fluorescence data and has the best performance, with sensitivity, specificity, negative predictive value, and positive predictive value for correctly identifying adenocarcinoma being 85, 89, 92, and 80%, respectively.

  19. Inferring biomarkers for Mycobacterium avium subsp. paratuberculosis infection and disease progression in cattle using experimental data

    NASA Astrophysics Data System (ADS)

    Magombedze, Gesham; Shiri, Tinevimbo; Eda, Shigetoshi; Stabel, Judy R.

    2017-03-01

    Available diagnostic assays for Mycobacterium avium subsp. paratuberculosis (MAP) have poor sensitivities and cannot detect early stages of infection, therefore, there is need to find new diagnostic markers for early infection detection and disease stages. We analyzed longitudinal IFN-γ, ELISA-antibody and fecal shedding experimental sensitivity scores for MAP infection detection and disease progression. We used both statistical methods and dynamic mathematical models to (i) evaluate the empirical assays (ii) infer and explain biological mechanisms that affect the time evolution of the biomarkers, and (iii) predict disease stages of 57 animals that were naturally infected with MAP. This analysis confirms that the fecal test is the best marker for disease progression and illustrates that Th1/Th2 (IFN-γ/ELISA antibodies) assays are important for infection detection, but cannot reliably predict persistent infections. Our results show that the theoretical simulated macrophage-based assay is a potential good diagnostic marker for MAP persistent infections and predictor of disease specific stages. We therefore recommend specifically designed experiments to test the use of a based assay in the diagnosis of MAP infections.

  20. External quality assessment studies for laboratory performance of molecular and serological diagnosis of Chikungunya virus infection.

    PubMed

    Jacobsen, Sonja; Patel, Pranav; Schmidt-Chanasit, Jonas; Leparc-Goffart, Isabelle; Teichmann, Anette; Zeller, Herve; Niedrig, Matthias

    2016-03-01

    Since the re-emergence of Chikungunya virus (CHIKV) in Reunion in 2005 and the recent outbreak in the Caribbean islands with an expansion to the Americas the CHIK diagnostic became very important. We evaluate the performance of laboratories regarding molecular and serological diagnostic of CHIK worldwide. A panel of 12 samples for molecular and 13 samples for serology were provided to 60 laboratories in 40 countries for evaluating the sensitivity and specificity of molecular and serology testing. The panel for molecular diagnostic testing was analysed by 56 laboratories returning 60 data sets of results whereas the 56 and 60 data sets were returned for IgG and IgM diagnostic from the participating laboratories. Twenty-three from 60 data sets performed optimal, 7 acceptable and 30 sets of results require improvement. From 50 data sets only one laboratory shows an optimal performance for IgM detection, followed by 9 data sets with acceptable and the rest need for improvement. From 46 IgG serology data sets 20 provide an optimal, 2 an acceptable and 24 require improvement performance. The evaluation of some of the diagnostic performances allows linking the quality of results to the in-house methods or commercial assays used. The external quality assurance for CHIK diagnostics provides a good overview on the laboratory performance regarding sensitivity and specificity for the molecular and serology diagnostic required for the quick and reliable analysis of suspected CHIK patients. Nearly half of the laboratories have to improve their diagnostic profile to achieve a better performance. Copyright © 2016 Z. Published by Elsevier B.V. All rights reserved.

  1. Chilean version of the INECO Frontal Screening (IFS-Ch): psychometric properties and diagnostic accuracy

    PubMed Central

    Jory, Josefina Ihnen; Bruna, Andrés Antivilo; Muñoz-Neira, Carlos; Chonchol, Andrea Slachevsky

    2013-01-01

    OBJECTIVE This study sought to analyze the psychometric properties and diagnostic accuracy of the Chilean version of the INECO Frontal Screening (IFS-Ch) in a sample of dementia patients and control subjects. METHODS After adapting the instrument to the Chilean context and obtaining content validity evidence through expert consultation, the IFS-Ch was administered to 31 dementia patients and 30 control subjects together with other executive assessments (Frontal Assessment Battery [FAB], Modified version of the Wisconsin Card Sorting Test [MCST], phonemic verbal fluencies [letters A and P] and semantic verbal fluency [animals]) and global cognitive efficiency tests (Mini mental State Examination [MMSE] and Addenbrooke's Cognitive Examination-Revised [ACE-R]). Caregivers of dementia patients and proxies of control subjects were interviewed with instruments measuring dysexecutive symptoms (Dysexecutive Questionnaire [DEX]), dementia severity (Clinical Dementia Rating Scale [CDR]) and functional status in activities of daily living (Activities of Daily Living Scale [IADL] and Technology-Activities of Daily Living Questionnaire [T-ADLQ]). Convergent and discriminant validity, internal consistency reliability, cut-off points, sensitivity and specificity for the IFS-Ch were estimated. RESULTS Evidence of content validity was obtained. Evidence of convergent validity was also found showing significant correlations (p<0.05) between the IFS-Ch and the other instruments measuring: executive functions (FAB, r=0.935; categories achieved in the MCST, r=0.791; perseverative errors in the MCST, r= -0.617; animal verbal fluency, r=0.728; "A" verbal fluency, r=0.681; and "P" verbal fluency, r=0.783), dysexecutive symptoms in daily living (DEX, r= -0.494), dementia severity (CDR, r= -0.75) and functional status in activities of daily living (T-ADLQ, r= -0.745; IADL, r=0.717). Regarding reliability, a Cronbach's alpha coefficient of 0.905 was obtained. For diagnostic accuracy, a cut-off point of 18 points (sensitivity=0.903; specificity=0.867) and an area under curve of 0.951 were estimated to distinguish between patients with dementia and control subjects. DISCUSSION The IFS-Ch showed acceptable psychometric properties, supported by evidence of validity and reliability for its use in the measurement of executive functions in patients with dementia. The diagnostic accuracy of the IFS-Ch for detecting dementia patients was also considered acceptable. PMID:29213818

  2. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability.

    PubMed

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-09-01

    There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee.

  3. A hypothesis-driven physical examination learning and assessment procedure for medical students: initial validity evidence.

    PubMed

    Yudkowsky, Rachel; Otaki, Junji; Lowenstein, Tali; Riddle, Janet; Nishigori, Hiroshi; Bordage, Georges

    2009-08-01

    Diagnostic accuracy is maximised by having clinical signs and diagnostic hypotheses in mind during the physical examination (PE). This diagnostic reasoning approach contrasts with the rote, hypothesis-free screening PE learned by many medical students. A hypothesis-driven PE (HDPE) learning and assessment procedure was developed to provide targeted practice and assessment in anticipating, eliciting and interpreting critical aspects of the PE in the context of diagnostic challenges. This study was designed to obtain initial content validity evidence, performance and reliability estimates, and impact data for the HDPE procedure. Nineteen clinical scenarios were developed, covering 160 PE manoeuvres. A total of 66 Year 3 medical students prepared for and encountered three clinical scenarios during required formative assessments. For each case, students listed anticipated positive PE findings for two plausible diagnoses before examining the patient; examined a standardised patient (SP) simulating one of the diagnoses; received immediate feedback from the SP, and documented their findings and working diagnosis. The same students later encountered some of the scenarios during their Year 4 clinical skills examination. On average, Year 3 students anticipated 65% of the positive findings, correctly performed 88% of the PE manoeuvres and documented 61% of the findings. Year 4 students anticipated and elicited fewer findings overall, but achieved proportionally more discriminating findings, thereby more efficiently achieving a diagnostic accuracy equivalent to that of students in Year 3. Year 4 students performed better on cases on which they had received feedback as Year 3 students. Twelve cases would provide a reliability of 0.80, based on discriminating checklist items only. The HDPE provided medical students with a thoughtful, deliberate approach to learning and assessing PE skills in a valid and reliable manner.

  4. Detection of proximal caries using quantitative light-induced fluorescence-digital and laser fluorescence: a comparative study.

    PubMed

    Yoon, Hyung-In; Yoo, Min-Jeong; Park, Eun-Jin

    2017-12-01

    The purpose of this study was to evaluate the in vitro validity of quantitative light-induced fluorescence-digital (QLF-D) and laser fluorescence (DIAGNOdent) for assessing proximal caries in extracted premolars, using digital radiography as reference method. A total of 102 extracted premolars with similar lengths and shapes were used. A single operator conducted all the examinations using three different detection methods (bitewing radiography, QLF-D, and DIAGNOdent). The bitewing x-ray scale, QLF-D fluorescence loss (ΔF), and DIAGNOdent peak readings were compared and statistically analyzed. Each method showed an excellent reliability. The correlation coefficient between bitewing radiography and QLF-D, DIAGNOdent were -0.644 and 0.448, respectively, while the value between QLF-D and DIAGNOdent was -0.382. The kappa statistics for bitewing radiography and QLF-D had a higher diagnosis consensus than those for bitewing radiography and DIAGNOdent. The QLF-D was moderately to highly accurate (AUC = 0.753 - 0.908), while DIAGNOdent was moderately to less accurate (AUC = 0.622 - 0.784). All detection methods showed statistically significant correlation and high correlation between the bitewing radiography and QLF-D. QLF-D was found to be a valid and reliable alternative diagnostic method to digital bitewing radiography for in vitro detection of proximal caries.

  5. Diagnostic Health Monitoring System Development for Army Vehicle Reliability

    DTIC Science & Technology

    2011-07-01

    19-24 3.4 Receiver Operator Characteristics for fault detection ……………………….. 24-28 3.5 Extended diagnostic speed bump modal data analysis...extended diagnostic speed bump was akin to the use of modal impact testing for exciting broadband frequency ranges in mechanical systems for use in...for a front axle wheel crossing measured using long cleat for ( ) first 30, ( ) second 11, ( ) third 11, ( ) fourth 11, and ( ) fifth 11 data series

  6. Reducing case ascertainment costs in US population studies of Alzheimer's disease, dementia, and cognitive impairment—Part 1*

    PubMed Central

    Weir, David R.; Wallace, Robert B.; Langa, Kenneth M.; Plassman, Brenda L.; Wilson, Robert S.; Bennett, David A.; Duara, Ranjan; Loewenstein, David; Ganguli, Mary; Sano, Mary

    2011-01-01

    Establishing methods for ascertainment of dementia and cognitive impairment that are accurate and also cost effective is a challenging enterprise. Large population-based studies often using administrative data sets offer relatively inexpensive but reliable estimates of severe conditions including moderate to advanced dementia that are useful for public health planning, but they can miss less severe cognitive impairment which may be the most effective point for intervention. Clinical and epidemiological cohorts, intensively assessed, provide more sensitive detection of less severe cognitive impairment but are often costly. Here, several approaches to ascertainment are evaluated for validity, reliability, and cost. In particular, the methods of ascertainment from the Health and Retirement Study (HRS) are described briefly, along with those of the Aging, Demographics, and Memory Study (ADAMS). ADAMS, a resource-intense sub-study of the HRS, was designed to provide diagnostic accuracy among persons with more advanced dementia. A proposal to streamline future ADAMS assessments is offered. Also considered are decision tree, algorithmic, and web-based approaches to diagnosis that can reduce the expense of clinical expertise and, in some contexts, can reduce the extent of data collection. These approaches are intended for intensively assessed epidemiological cohorts. The goal is valid and reliable detection with efficient and cost-effective tools. PMID:21255747

  7. Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.

    PubMed

    Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline

    2015-11-01

    Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.

  8. The intra- and inter-observer reliability of the physical examination methods used to assess patients with patellofemoral joint instability.

    PubMed

    Smith, Toby O; Clark, Allan; Neda, Sophia; Arendt, Elizabeth A; Post, William R; Grelsamer, Ronald P; Dejour, David; Almqvist, Karl Fredrik; Donell, Simon T

    2012-08-01

    An accurate physical examination of patients with patellar instability is an important aspect of the diagnosis and treatment. While previous studies have assessed the diagnostic accuracy of such physical examination tests, little has been undertaken to assess the inter- and intra-tester reliability of such techniques. The purpose of this study was to determine the inter- and intra-tester reliability of the physical examination tests used for patients with patellar instability. Five patients (10 knees) with bilateral recurrent patellar instability were assessed by five members of the International Patellofemoral Study Group. Each surgeon assessed each patient twice using 18 reported physical examination tests. The inter- and intra-observer reliability was assessed using weighted Kappa statistics with 95% confidence intervals. The findings of the study suggested that there were very poor inter-observer reliability for the majority of the physical tests, with only the assessments of patellofemoral crepitus, foot arch position and the J-sign presenting with fair to moderate agreement respectively. The intra-observer reliability indicated largely moderate to substantial agreement between the first and second tests performed by each assessor, with the greatest agreement seen for the assessment of tibial torsion, popliteal angle and the Bassett's sign. For the common physical examination tests used in the management of patients with patellar instability inter-observer reliability is poor, while intra-observer reliability is moderate. Standardization of physical exam assessments and further study of these results among different clinicians and more divergent patient groups is indicated. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Advance in diagnosis of female genital tract tumor with laser fluorescence

    NASA Astrophysics Data System (ADS)

    Ding, Ai-Hua; Tseng, Quen; Lian, Shao-Hui

    1998-11-01

    In order to improve the diagnostic accuracy of malignant tumors with laser fluorescence, in 1996, our group successfully created the computerized laser fluorescence spectrograph type II with more reliable images shown overshadowing the naked eye method before 74 cases of female genital tract diseases had been examined by the LFS II resulting in 10 positive cases which were also proven pathologically as malignant tumors, without nay false negative, 3 cases presented suspicious positive but all were proven pathologically as non-tumors lesions, the false positive rate was 4 percent. Our work showed that the method of LFS II can provide a more rapid and accurate diagnosis for the clinical malignant tumors.

  10. Mass Spectrometry for Paper-Based Immunoassays: Toward On-Demand Diagnosis.

    PubMed

    Chen, Suming; Wan, Qiongqiong; Badu-Tawiah, Abraham K

    2016-05-25

    Current analytical methods, either point-of-care or centralized detection, are not able to meet recent demands of patient-friendly testing and increased reliability of results. Here, we describe a two-point separation on-demand diagnostic strategy based on a paper-based mass spectrometry immunoassay platform that adopts stable and cleavable ionic probes as mass reporter; these probes make possible sensitive, interruptible, storable, and restorable on-demand detection. In addition, a new touch paper spray method was developed for on-chip, sensitive, and cost-effective analyte detection. This concept is successfully demonstrated via (i) the detection of Plasmodium falciparum histidine-rich protein 2 antigen and (ii) multiplexed and simultaneous detection of cancer antigen 125 and carcinoembryonic antigen.

  11. Evaluating concentration estimation errors in ELISA microarray experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daly, Don S.; White, Amanda M.; Varnum, Susan M.

    Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to predict a protein concentration in a sample. Deploying ELISA in a microarray format permits simultaneous prediction of the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Evaluating prediction error is critical to interpreting biological significance and improving the ELISA microarray process. Evaluating prediction error must be automated to realize a reliable high-throughput ELISA microarray system. Methods: In this paper, we present a statistical method based on propagation of error to evaluate prediction errors in the ELISA microarray process. Althoughmore » propagation of error is central to this method, it is effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization and statistical diagnostics when evaluating ELISA microarray prediction errors. We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of prediction errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error.« less

  12. Approach to Operational Experimental Estimation of Static Stresses of Elements of Mechanical Structures

    NASA Astrophysics Data System (ADS)

    Sedov, A. V.; Kalinchuk, V. V.; Bocharova, O. V.

    2018-01-01

    The evaluation of static stresses and strength of units and components is a crucial task for increasing reliability in the operation of vehicles and equipment, to prevent emergencies, especially in structures made of metal and composite materials. At the stage of creation and commissioning of structures to control the quality of manufacturing of individual elements and components, diagnostic control methods are widely used. They are acoustic, ultrasonic, X-ray, radiation methods and others. The using of these methods to control the residual life and the degree of static stresses of units and parts during operation is fraught with great difficulties both in methodology and in instrumentation. In this paper, the authors propose an effective approach of operative control of the degree of static stresses of units and parts of mechanical structures which are in working condition, based on recording the changing in the surface wave properties of a system consisting of a sensor and a controlled environment (unit, part). The proposed approach of low-frequency diagnostics of static stresses presupposes a new adaptive-spectral analysis of a surface wave created by external action (impact). It is possible to estimate implicit stresses of structures in the experiment due to this approach.

  13. Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors.

    PubMed

    Ray, Monalisa; Ray, Asit; Dash, Swagatika; Mishra, Abtar; Achary, K Gopinath; Nayak, Sanghamitra; Singh, Shikha

    2017-01-15

    Fungal diseases in commercially important plants results in a significant reduction in both quality and yield, often leading to the loss of an entire plant. In order to minimize the losses, it is essential to detect and identify the pathogens at an early stage. Early detection and accurate identification of pathogens can control the spread of infection. The present article provides a comprehensive overview of conventional methods, current trends and advances in fungal pathogen detection with an emphasis on biosensors. Traditional techniques are the "gold standard" in fungal detection which relies on symptoms, culture-based, morphological observation and biochemical identifications. In recent times, with the advancement of biotechnology, molecular and immunological approaches have revolutionized fungal disease detection. But the drawback lies in the fact that these methods require specific and expensive equipments. Thus, there is an urgent need for rapid, reliable, sensitive, cost effective and easy to use diagnostic methods for fungal pathogen detection. Biosensors would become a promising and attractive alternative, but they still have to be subjected to some modifications, improvements and proper validation for on-field use. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. [The evaluation of sensitivity and specificity of technique of detection of C-reactive protein under diagnostic of infectious complications in patients with acute lymphoblastic leucosis receiving chemotherapy].

    PubMed

    Vladimirova, S G; Tarasova, L N; Dokshina, I A; Cherepanova, V A

    2014-11-01

    The C-reactive protein is a generally recognized marker of inflammation and bacterial infection. However, issue of diagnostic effectiveness of this indicator is still open-ended in case of patients with oncologic hematological diseases. The level of C-reactive protein can increase under neoplastic processes. On the contrary, the inhibition of immune response observed under cytoplastic therapy can decrease synthesis of this protein. The study was organized to establish levels of C-reactive protein as markers of infection in adult patients with acute lymphoblastic leucosis under application of chemotherapy and to evaluate their diagnostic effectiveness. The sampling included 34 patients with acute lymphoblastic leucosis all patients had infectious complications at various stages of treatment. The levels of C-reactive protein in groups of patients with localized infections (mucositis, abscess, pneumonia, etc.) or fever of unknown genesis had no statistical differences but were reliably higher in patients without infectious complications. The concentrations of C-reactive protein in patients with syndrome of systemic inflammatory response and sepsis had no differences. At the same time, level of C-reactive protein under systemic infection (syndrome of systemic inflammatory response, sepsis) was reliably higher than in case of localized infection. The diagnostically reliable levels of C-reactive protein were established as follows: lower than 11 mg/l--infectious complications are lacking; higher than 11 mg/l--availability of infectious process; higher than 82 mg/l--generalization of infection. The given levels are characterized by high diagnostic sensitivity (92% and 97% correspondingly) and specificity (97% and 97%) when patients receive therapy without application of L-asparaginase. At the stages of introduction of this preparation effecting protein synthesizing function of liver sensitivity of proposed criteria are decreased (69% and 55% correspondingly). However; due to high specificity (100% and 96%) their diagnostic effectiveness remains high.

  15. Research Review: Test-retest reliability of standardized diagnostic interviews to assess child and adolescent psychiatric disorders: a systematic review and meta-analysis.

    PubMed

    Duncan, Laura; Comeau, Jinette; Wang, Li; Vitoroulis, Irene; Boyle, Michael H; Bennett, Kathryn

    2018-02-19

    A better understanding of factors contributing to the observed variability in estimates of test-retest reliability in published studies on standardized diagnostic interviews (SDI) is needed. The objectives of this systematic review and meta-analysis were to estimate the pooled test-retest reliability for parent and youth assessments of seven common disorders, and to examine sources of between-study heterogeneity in reliability. Following a systematic review of the literature, multilevel random effects meta-analyses were used to analyse 202 reliability estimates (Cohen's kappa = ҡ) from 31 eligible studies and 5,369 assessments of 3,344 children and youth. Pooled reliability was moderate at ҡ = .58 (CI 95% 0.53-0.63) and between-study heterogeneity was substantial (Q = 2,063 (df = 201), p < .001 and I 2  = 79%). In subgroup analysis, reliability varied across informants for specific types of psychiatric disorder (ҡ = .53-.69 for parent vs. ҡ = .39-.68 for youth) with estimates significantly higher for parents on attention deficit hyperactivity disorder, oppositional defiant disorder and the broad groupings of externalizing and any disorder. Reliability was also significantly higher in studies with indicators of poor or fair study methodology quality (sample size <50, retest interval <7 days). Our findings raise important questions about the meaningfulness of published evidence on the test-retest reliability of SDIs and the usefulness of these tools in both clinical and research contexts. Potential remedies include the introduction of standardized study and reporting requirements for reliability studies, and exploration of other approaches to assessing and classifying child and adolescent psychiatric disorder. © 2018 Association for Child and Adolescent Mental Health.

  16. Reliability of a New Radiographic Classification for Developmental Dysplasia of the Hip.

    PubMed

    Narayanan, Unni; Mulpuri, Kishore; Sankar, Wudbhav N; Clarke, Nicholas M P; Hosalkar, Harish; Price, Charles T

    2015-01-01

    Existing radiographic classification schemes (eg, Tönnis criteria) for DDH quantify the severity of disease based on the position of the ossific nucleus relative to Hilgenreiner's and Perkin's lines. By definition, this method requires the presence of an ossification centre, which can be delayed in appearance and eccentric in location within the femoral head. A new radiographic classification system has been developed by the International Hip Dysplasia Institute (IHDI), which uses the mid-point of the proximal femoral metaphysis as a reference landmark, and can therefore be applied to children of all ages. The purpose of this study was to compare the reliability of this new method with that of Tönnis, as the first step in establishing its validity and clinical utility. Twenty standardized anteroposterior pelvic radiographs of children with untreated DDH were selected purposefully to capture the spectrum of age (range, 3 to 32 mo) at presentation and disease severity. Each of the hips was classified separately by the IHDI and Tönnis methods by 6 experienced pediatric orthopaedists from the United States, Canada, Mexico, United Kingdom, and by 2 orthopaedic senior residents. The inter-rater reliability was tested using the Intra Class Correlation coefficient (ICC) to measure concordance between raters. All 40 hips were classifiable by the IHDI method by all raters. Ten of the 40 hips could not be classified by the Tönnis method because of the absence of the ossific nucleus on one or both sides. The ICC (95% confidence interval) for the IHDI method for all raters was 0.90 (0.83-0.95) and 0.95 (0.91-0.98) for the right and left hips, respectively. The corresponding ICCs for the Tönnis method were 0.63 (0.46-0.80) and 0.60 (0.43-0.78), respectively. There was no significant difference between the ICCs of the 6 experts and 2 trainees. The IHDI method of classification has excellent inter-rater reliability, both among experts and novices, and is more widely applicable than the Tönnis method as it can be applied even when the ossification centre is absent. Level II (diagnostic).

  17. The Clinical Utility and Diagnostic Performance of MRI for Identification of Early and Advanced Knee Osteoarthritis: A Systematic Review

    PubMed Central

    Quatman, Carmen E.; Hettrich, Carolyn M.; Schmitt, Laura C.; Spindler, Kurt P.

    2013-01-01

    Background Current diagnostic strategies for detection of structural articular cartilage abnormalities, the earliest structural signs of osteoarthritis, often do not capture the condition until it is too far advanced for the most potential benefit of non-invasive interventions. Purpose Systematically review the literature relative to the following questions: (1) Is MRI a valid, sensitive, specific, accurate and reliable instrument to identify knee articular cartilage abnormalities compared to arthroscopy? (2) Is MRI a sensitive tool that can be utilized to identify early cartilage degeneration? Study Design Systematic Review Methods A systematic search was performed in November 2010 using PubMed MEDLINE (from 1966), CINAHL (from 1982), SPORTDiscus (from 1985), and SCOPUS (from 1996) databases. Results Fourteen level I and 13 level II studies were identified that met inclusion criteria and provided information related to diagnostic performance of MRI compared to arthroscopic evaluation. The diagnostic performance of MRI demonstrated a large range of sensitivities, specificities, and accuracies. The sensitivity for identifying articular cartilage abnormalities in the knee joint was reported between 26–96%. Specificity and accuracy was reported between 50–100% and 49–94%, respectively. The sensitivity, specificity, and accuracy for identifying early osteoarthritis were reported between 0–86%, 48–95%, and 5–94%, respectively. As a result of inconsistencies between imaging techniques and methodological shortcomings of many of the studies, a meta-analysis was not performed and it was difficult to fully synthesize the information to state firm conclusions about the diagnostic performance of MRI. Conclusions There is evidence in some MRI protocols that MRI is a relatively valid, sensitive, specific, accurate, and reliable clinical tool for identifying articular cartilage degeneration. Due to heterogeneity of MRI sequences it is not possible to make definitive conclusions regarding its global clinical utility for guiding diagnosis and treatment strategies. Clinical Relevance Traumatic sports injuries to the knee may be significant precursor events to early onset of posttraumatic osteoarthritis. MRI may aid in early identification of structural injuries to articular cartilage as evidenced by articular cartilage degeneration grading. PMID:21730207

  18. Diagnostic validity of early-onset obsessive-compulsive disorder in the Danish Psychiatric Central Register: findings from a cohort sample

    PubMed Central

    Powell, Shelagh; Koch, Susanne V; Crowley, James J; Matthiesen, Manuel; Grice, Dorothy E; Thomsen, Per H; Parner, E

    2017-01-01

    Objectives Employing national registers for research purposes depends on a high diagnostic validity. The aim of the present study was to examine the diagnostic validity of recorded diagnoses of early-onset obsessive-compulsive disorder (OCD) in the Danish Psychiatric Central Register (DPCR). Design Review of patient journals selected randomly through the DPCR. Method One hundred cases of OCD were randomly selected from DPCR. Using a predefined coding scheme based on the Children’s Yale Brown Obsessive Compulsive Scale (CYBOCS), experienced research nurse or child and adolescent psychiatrists assessed each journal to determine the presence/absence of OCD diagnostic criteria. The detailed assessments were reviewed by two senior child and adolescent psychiatrists to determine if diagnostic criteria were met. Primary outcome measurements Positive predictive value (PPV) was used as the primary outcome measurement. Results A total of 3462 children/adolescents received an OCD diagnosis as the main diagnosis between 1 January 1995 and 31 December 2015. The average age at diagnosis was 13.21±2.89 years. The most frequent registered OCD subcode was the combined diagnosis DF42.2. Of the 100 cases we examined, 35 had at least one registered comorbidity. For OCD, the PPV was good (PPV 0.85). Excluding journals with insufficient information, the PPV was 0.96. For the subcode F42.2 the PPV was 0.77. The inter-rater reliability was 0.94. The presence of the CYBOCS in the journal significantly increased the PPV for the OCD diagnosis altogether and for the subcode DF42.2. Conclusion The validity and reliability of International Classification of Disease 10th revision codes for OCD in the DPCR is generally high. The subcodes for predominant obsessions/predominant compulsions are less certain and should be used with caution. The results apply for both children and adolescents and for both older and more recent cases. Altogether, the study suggests that there is a high validity of the OCD diagnosis in the Danish National Registers. PMID:28928194

  19. Between-Person and Within-Person Subscore Reliability: Comparison of Unidimensional and Multidimensional IRT Models

    ERIC Educational Resources Information Center

    Bulut, Okan

    2013-01-01

    The importance of subscores in educational and psychological assessments is undeniable. Subscores yield diagnostic information that can be used for determining how each examinee's abilities/skills vary over different content domains. One of the most common criticisms about reporting and using subscores is insufficient reliability of subscores.…

  20. Establishing the Validity and Reliability of Course Evaluation Questionnaires

    ERIC Educational Resources Information Center

    Kember, David; Leung, Doris Y. P.

    2008-01-01

    This article uses the case of designing a new course questionnaire to discuss the issues of validity, reliability and diagnostic power in good questionnaire design. Validity is often not well addressed in course questionnaire design as there are no straightforward tests that can be applied to an individual instrument. The authors propose the…

  1. Gender differences in diagnosing antisocial personality disorder in methadone patients.

    PubMed

    Rutherford, M J; Alterman, A I; Cacciola, J S; Snider, E C

    1995-09-01

    The goal of this study was to evaluate gender differences in the prevalence rates, short-term reliability, and internal consistency of the diagnosis of antisocial personality disorder for DSM-III-R, DSM-III, and Research Diagnostic Criteria (RDC). A total of 37 men and 57 women methadone patients were diagnosed according to DSM-III-R, DSM-III, and RDC antisocial personality disorder criteria. The diagnostic rates, reliability, and internal consistency were lower for women than for men in all systems. DSM-III criteria resulted in the highest reliability for women, but for men, the DSM-III criteria were the least reliable. Examination of endorsement rates of individual antisocial personality disorder criteria revealed several significant gender differences on the majority of childhood criteria and on several adult criteria. Item-total correlations revealed that for women, the violent and aggressive childhood criteria in DSM-III-R that had not been included in DSM-III or RDC had a negative or no correlation to the assessment of antisocial personality disorder for women. The change in DSM-III-R from DSM-III childhood criteria appears to have resulted in a decrease in internal consistency and rates of antisocial personality disorder for women, but not for men. The results of this investigation indicate that the psychometric properties of the current antisocial personality disorder scales are weak for women, compared with men. To assess antisocial personality disorder in women it may be necessary to revise current, or develop new, diagnostic criteria.

  2. Detection of Orthopoxvirus DNA by Real-Time PCR and Identification of Variola Virus DNA by Melting Analysis

    PubMed Central

    Nitsche, Andreas; Ellerbrok, Heinz; Pauli, Georg

    2004-01-01

    Although variola virus was eradicated by the World Health Organization vaccination program in the 1970s, the diagnosis of smallpox infection has attracted great interest in the context of a possible deliberate release of variola virus in bioterrorist attacks. Obviously, fast and reliable diagnostic tools are required to detect variola virus and to distinguish it from orthopoxviruses that have identical morphological characteristics, including vaccinia virus. The advent of real-time PCR for the clinical diagnosis of viral infections has facilitated the detection of minute amounts of viral nucleic acids in a fast, safe, and precise manner, including the option to quantify and to genotype the target reliably. In this study a complete set of four hybridization probe-based real-time PCR assays for the specific detection of orthopoxvirus DNA is presented. Melting analysis following PCR enables the identification of variola virus by the PCR product's characteristic melting temperature, permitting the discrimination of variola virus from other orthopoxviruses. In addition, an assay for the specific amplification of variola virus DNA is presented. All assays can be performed simultaneously in the same cycler, and results of a PCR run are obtained in less than 1 h. The application of more than one assay for the same organism significantly contributes to the diagnostic reliability, reducing the risk of false-negative results due to unknown sequence variations. In conclusion, the assays presented will improve the speed and reliability of orthopoxvirus diagnostics and variola virus identification. PMID:15004077

  3. Knowledge translation from continuing education to physiotherapy practice in classifying patients with low back pain.

    PubMed

    Karvonen, Eira; Paatelma, Markku; Kesonen, Jukka-Pekka; Heinonen, Ari O

    2015-05-01

    Physical therapists have used continuing education as a method of improving their skills in conducting clinical examination of patients with low back pain (LBP). The purpose of this study was to evaluate how well the pathoanatomical classification of patients in acute or subacute LBP can be learned and applied through a continuing education format. The patients were seen in a direct access setting. The study was carried out in a large health-care center in Finland. The analysis included a total of 57 patient evaluations generated by six physical therapists on patients with LBP. We analyzed the consistency and level of agreement of the six physiotherapists' (PTs) diagnostic decisions, who participated in a 5-day, intensive continuing education session and also compared those with the diagnostic opinions of two expert physical therapists, who were blind to the original diagnostic decisions. Evaluation of the physical therapists' clinical examination of the patients was conducted by the two experts, in order to determine the accuracy and percentage agreement of the pathoanatomical diagnoses. The percentage of agreement between the experts and PTs was 72-77%. The overall inter-examiner reliability (kappa coefficient) for the subgroup classification between the six PTs and two experts was 0.63 [95% confidence interval (CI): 0.47-0.77], indicating good agreement between the PTs and the two experts. The overall inter-examiner reliability between the two experts was 0.63 (0.49-0.77) indicating good level of agreement. Our results indicate that PTs' were able to apply their continuing education training to clinical reasoning and make consistently accurate pathoanatomic based diagnostic decisions for patients with LBP. This would suggest that continuing education short-courses provide a reasonable format for knowledge translation (KT) by which physical therapists can learn and apply new information related to the examination and differential diagnosis of patients in acute or subacute LBP.

  4. Salivary diagnostics and its impact in dentistry, research, education, and the professional community.

    PubMed

    Slavkin, H C; Fox, C H; Meyer, D M

    2011-10-01

    Oral fluid-based (salivary) tests have the potential to create practical, point-of-care clinical instruments that are convenient, practical, and comfortable to use in dentistry and medicine. Currently, there are no simple, accurate, and inexpensive sampling, screening, or detection methods to support definitive diagnostic platforms across dental and medical disciplines. Though the benefits from advancing screening and detection technologies seem eminent, analytical, chemical, molecular, genetic, and protein markers are still under development. Clinical applications in patient care must be validated independently to ensure that they are clinically accurate, reliable, precise, and uniformly consistent for screening and detecting specific diseases or conditions. As technology designed to improve patient care through risk assessment, prevention, and disease management is transferred into clinical practice, dentistry may need to reassess its role in general health care. © International & American Associations for Dental Research

  5. Fungal infections in burns: a comprehensive review

    PubMed Central

    Struck, M.F.; Gille, J.

    2013-01-01

    Summary Burn wound infections remain the most important factor limiting survival in burn intensive care units. Large wound surface, impaired immune systems, and broad-spectrum antibiotic therapy contribute to the growth of opportunistic fungal species. Faced with challenging fluid resuscitation, wound excision and cardiopulmonary stabilization, mycosis in burns are likely to be underestimated. Diagnostic performance can sometimes be delayed because clinical signs are unspecific and differentiation between colonization and infection is difficult. Therapeutic measures range from infection prophylaxis over treatment with antifungal agents towards radical amputation of infected limbs. New methods of early and reliable detection of fungal organisms, as well as the use of novel antifungal substances, are promising but require wider establishment to confirm the beneficial effects in burn patients. This review aims to highlight the main important aspects of fungal infections in burns including incidence, infection control, diagnostic and therapeutic approaches, prognosis and outcomes. PMID:24563641

  6. [The features of opisthorchiasis papillitis diagnosis].

    PubMed

    Onishchenko, S V; Darvin, V V; Klimova, N V; Krasnov, E A

    2018-01-01

    To develop an optimal diagnostic algorithm in order to the most reliable decrease of inflammatory changes severity in large duodenal papilla in patients with chronic opisthorchiasis. Medical reports of 384 patients with opisthorchiasis-induced cholangitis have been analyzed. Diagnostic methods were abdominal ultrasound, endoscopic ultrasound of terminal common bile duct, CT scans, MRI of abdominal organs including magnetic resonance cholangiopancreatography and esophagogastroduodenoscopy with biopsy of the papilla, ERCP and PTHC. Comprehensive general and individual analysis of each of them has determined their advantages and disadvantages. Examination should by comprehensive to evaluate visual appearance of large duodenal papilla, lumen dimensions, state of its walls with histological research. Imaging tests are favorable to determine the diagnosis of papillitis due to possible assessment of lumen dimensions and state of the walls. While making a choice the priority should be given to endoscopic ultrasound examination. It allows visual inspection, assessment of the lumen, the walls of papilla and provides biopsy of deep structures.

  7. Laboratory diagnosis of invasive candidiasis.

    PubMed Central

    Jones, J M

    1990-01-01

    Severe infections due to Candida species have become more frequent during the past two decades because of the increasing numbers of immunosuppressed patients being treated in our hospitals. Distinguishing colonization from invasive disease requires knowledge of the pathogenetic mechanisms leading to invasion. To assist the clinician in therapeutic decisions, clinical microbiologists should identify to species Candida organisms isolated from immunosuppressed patients. Quantitative or semiquantitative cultures of urine, burn tissues, intravascular catheter tips, and bronchoalveolar lavage specimens may provide useful information. Immunofluorescent staining of certain specimens can enhance diagnostic yield. The lysis-centrifugation blood culture technique offers some advantages over traditional broth techniques in detecting Candida fungemia. Antibody testing is of limited diagnostic value in highly immunosuppressed patients. Developing simple and reliable tests for detecting antigens or metabolites of Candida spp. in the sera of infected patients has proven difficult. Methods for typing Candida albicans are evolving. Typing should prove useful for studying the epidemiology of candidiasis in hospitalized patients. Images PMID:2404567

  8. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    PubMed Central

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid and accurate system can be introduced as a useful diagnostic system for comprehensive treatment of breast cancer. Another advantage of this method is the possibility of diagnosing breast abnormalities. If done by experts, FNA can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. PMID:25352966

  9. Improvement in the amine glass platform by bubbling method for a DNA microarray

    PubMed Central

    Jee, Seung Hyun; Kim, Jong Won; Lee, Ji Hyeong; Yoon, Young Soo

    2015-01-01

    A glass platform with high sensitivity for sexually transmitted diseases microarray is described here. An amino-silane-based self-assembled monolayer was coated on the surface of a glass platform using a novel bubbling method. The optimized surface of the glass platform had highly uniform surface modifications using this method, as well as improved hybridization properties with capture probes in the DNA microarray. On the basis of these results, the improved glass platform serves as a highly reliable and optimal material for the DNA microarray. Moreover, in this study, we demonstrated that our glass platform, manufactured by utilizing the bubbling method, had higher uniformity, shorter processing time, lower background signal, and higher spot signal than the platforms manufactured by the general dipping method. The DNA microarray manufactured with a glass platform prepared using bubbling method can be used as a clinical diagnostic tool. PMID:26468293

  10. Improvement in the amine glass platform by bubbling method for a DNA microarray.

    PubMed

    Jee, Seung Hyun; Kim, Jong Won; Lee, Ji Hyeong; Yoon, Young Soo

    2015-01-01

    A glass platform with high sensitivity for sexually transmitted diseases microarray is described here. An amino-silane-based self-assembled monolayer was coated on the surface of a glass platform using a novel bubbling method. The optimized surface of the glass platform had highly uniform surface modifications using this method, as well as improved hybridization properties with capture probes in the DNA microarray. On the basis of these results, the improved glass platform serves as a highly reliable and optimal material for the DNA microarray. Moreover, in this study, we demonstrated that our glass platform, manufactured by utilizing the bubbling method, had higher uniformity, shorter processing time, lower background signal, and higher spot signal than the platforms manufactured by the general dipping method. The DNA microarray manufactured with a glass platform prepared using bubbling method can be used as a clinical diagnostic tool.

  11. A review of MRI evaluation of demyelination in cuprizone murine model

    NASA Astrophysics Data System (ADS)

    Krutenkova, E.; Pan, E.; Khodanovich, M.

    2015-11-01

    The cuprizone mouse model of non-autoimmune demyelination reproduces some phenomena of multiple sclerosis and is appropriate for validation and specification of a new method of non-invasive diagnostics. In the review new data which are collected using the new MRI method are compared with one or more conventional MRI tools. Also the paper reviewed the validation of MRI approaches using histological or immunohistochemical methods. Luxol fast blue histological staining and myelin basic protein immunostaining is widespread. To improve the accuracy of non-invasive conventional MRI, multimodal scanning could be applied. The new quantitative MRI method of fast mapping of the macromolecular proton fraction is a reliable biomarker of myelin in the brain and can be used for research of demyelination in animals. To date, a validation of MPF method on the CPZ mouse model of demyelination is not performed, although this method is probably the best way to evaluate demyelination using MRI.

  12. Magnetic resonance neurography and diffusion tensor imaging: origins, history, and clinical impact of the first 50,000 cases with an assessment of efficacy and utility in a prospective 5000-patient study group.

    PubMed

    Filler, Aaron

    2009-10-01

    Methods were invented that made it possible to image peripheral nerves in the body and to image neural tracts in the brain. The history, physical basis, and dyadic tensor concept underlying the methods are reviewed. Over a 15-year period, these techniques-magnetic resonance neurography (MRN) and diffusion tensor imaging-were deployed in the clinical and research community in more than 2500 published research reports and applied to approximately 50,000 patients. Within this group, approximately 5000 patients having MRN were carefully tracked on a prospective basis. A uniform Neurography imaging methodology was applied in the study group, and all images were reviewed and registered by referral source, clinical indication, efficacy of imaging, and quality. Various classes of image findings were identified and subjected to a variety of small targeted prospective outcome studies. Those findings demonstrated to be clinically significant were then tracked in the larger clinical volume data set. MRN demonstrates mechanical distortion of nerves, hyperintensity consistent with nerve irritation, nerve swelling, discontinuity, relations of nerves to masses, and image features revealing distortion of nerves at entrapment points. These findings are often clinically relevant and warrant full consideration in the diagnostic process. They result in specific pathological diagnoses that are comparable to electrodiagnostic testing in clinical efficacy. A review of clinical outcome studies with diffusion tensor imaging also shows convincing utility. MRN and diffusion tensor imaging neural tract imaging have been validated as indispensable clinical diagnostic methods that provide reliable anatomic pathological information. There is no alternative diagnostic method in many situations. With the elapsing of 15 years, tens of thousands of imaging studies, and thousands of publications, these methods should no longer be considered experimental.

  13. George Papanicolaou's Efforts to Develop Novel Cytologic Methods for the Early Diagnosis of Endometrial Carcinoma.

    PubMed

    Austin, R Marshall

    2017-01-01

    Toward the end of his career, Dr. George Papanicolaou became interested in human endometrial explants placed into tissue culture. The initial focus of his studies was on phagocytic cells emanating from endometrial explants and their role in cleansing the uterine cavity after each menstrual cycle and in sterilizing the uterine cavity in the face of infection. Papanicolaou also observed that growth rates of explanted normal and pathologic endometrial tissues differed considerably. Explants of endometrial malignancies exhibited not only increased growth rates but also visible proliferation of cells with readily identifiable cytologic features of malignancy. Acknowledging that cytologic screening for early diagnosis of intrauterine malignancies had up to that point not proven to be reliable as screening for cervical cancer, he hoped that the tissue culture explant technique could prove to be a new adjunctive diagnostic method for the diagnosis of endometrial and other female genital tract malignancies not readily detectible by other diagnostic procedures. Papanicolaou's untimely death in 1962 cut short his progress in this area of study. © 2017 S. Karger AG, Basel.

  14. DNA-mounted self-assembly: new approaches for genomic analysis and SNP detection.

    PubMed

    Bichenkova, Elena V; Lang, Zhaolei; Yu, Xuan; Rogert, Candelaria; Douglas, Kenneth T

    2011-01-01

    This article presents an overview of new emerging approaches for nucleic acid detection via hybridization techniques that can potentially be applied to genomic analysis and SNP identification in clinical diagnostics. Despite the availability of a diverse variety of SNP genotyping technologies on the diagnostic market, none has truly succeeded in dominating its competitors thus far. Having been designed for specific diagnostic purposes or clinical applications, each of the existing bio-assay systems (briefly outlined here) is usually limited to a relatively narrow aspect or format of nucleic acid detection, and thus cannot entirely satisfy all the varieties of commercial requirements and clinical demands. This drives the diagnostic sector to pursue novel, cost-effective approaches to ensure rapid and reliable identification of pathogenic or hereditary human diseases. Hence, the purpose of this review is to highlight some new strategic directions in DNA detection technologies in order to inspire development of novel molecular diagnostic tools and bio-assay systems with superior reliability, reproducibility, robustness, accuracy and sensitivity at lower assay cost. One approach to improving the sensitivity of an assay to confidently discriminate between single point mutations is based on the use of target assembled, split-probe systems, which constitutes the main focus of this review. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Reliability of Diagnostic Criteria for Neurocysticercosis for Patients with Ventricular Cystic Lesions or Granulomas: A systematic review.

    PubMed

    Bustos, Javier A; García, Hector H; Del Brutto, Oscar H

    2017-09-01

    Intraventricular neurocysticercosis (NCC) is a severe form of NCC requiring prompt diagnosis and treatment. We aimed to assess the reliability of the most recent version of diagnostic criteria for this form of NCC. Two systematic literature reviews were performed; one included case reports of patients with intraventricular cysticercosis and the other included case reports of patients with intraventricular cystic lesions or granulomas caused by infections other than NCC. All assessed cases were categorized according to the last revision of the long-standing Del Brutto's set of diagnostic criteria to determine its sensitivity, specificity, and predictive value for this form of NCC. The search disclosed 128 patients with intraventricular NCC and 41 with other infections. The set of diagnostic criteria classified as definitive NCC 93 cases with intraventricular NCC (sensitivity 72.7%, 95% CI, 63.9-79.9%), as well as four cases with other infections (specificity 90.2%, 95% CI, 75.9-96.8%). The positive and negative predictive values of the criteria were 0.96 (95% CI, 0.89-0.99) and 0.51 (95% CI, 0.39-0.63), respectively. The revised Del Brutto's set of diagnostic criteria for NCC is acceptably sensitive and highly specific for diagnosing patients with the ventricular form of the disease.

  16. Intermittent explosive disorder: development of integrated research criteria for Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition.

    PubMed

    Coccaro, Emil F

    2011-01-01

    This study was designed to develop a revised diagnostic criteria set for intermittent explosive disorder (IED) for consideration for inclusion in Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-V). This revised criteria set was developed by integrating previous research criteria with elements from the current DSM-IV set of diagnostic criteria. Evidence supporting the reliability and validity of IED-IR ("IED Integrated Criteria") in a new and well-characterized group of subjects with personality disorder is presented. Clinical, phenomenologic, and diagnostic data from 201 individuals with personality disorder were reviewed. All IED diagnoses were assigned using a best-estimate process (eg, kappa for IED-IR >0.85). In addition, subjects meeting IED-IR criteria had higher scores on dimensional measures of aggression and had lower global functioning scores than non-IED-IR subjects, even when related variables were controlled. The IED-IR criteria were more sensitive than the DSM-IV criteria only in identifying subjects with significant impulsive-aggressive behavior by a factor of 16. We conclude that the IED-IR criteria can be reliably applied and have sufficient validity to warrant consideration as DSM-V criteria for IED. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Review of methods used by chiropractors to determine the site for applying manipulation

    PubMed Central

    2013-01-01

    Background With the development of increasing evidence for the use of manipulation in the management of musculoskeletal conditions, there is growing interest in identifying the appropriate indications for care. Recently, attempts have been made to develop clinical prediction rules, however the validity of these clinical prediction rules remains unclear and their impact on care delivery has yet to be established. The current study was designed to evaluate the literature on the validity and reliability of the more common methods used by doctors of chiropractic to inform the choice of the site at which to apply spinal manipulation. Methods Structured searches were conducted in Medline, PubMed, CINAHL and ICL, supported by hand searches of archives, to identify studies of the diagnostic reliability and validity of common methods used to identify the site of treatment application. To be included, studies were to present original data from studies of human subjects and be designed to address the region or location of care delivery. Only English language manuscripts from peer-reviewed journals were included. The quality of evidence was ranked using QUADAS for validity and QAREL for reliability, as appropriate. Data were extracted and synthesized, and were evaluated in terms of strength of evidence and the degree to which the evidence was favourable for clinical use of the method under investigation. Results A total of 2594 titles were screened from which 201 articles met all inclusion criteria. The spectrum of manuscript quality was quite broad, as was the degree to which the evidence favoured clinical application of the diagnostic methods reviewed. The most convincing favourable evidence was for methods which confirmed or provoked pain at a specific spinal segmental level or region. There was also high quality evidence supporting the use, with limitations, of static and motion palpation, and measures of leg length inequality. Evidence of mixed quality supported the use, with limitations, of postural evaluation. The evidence was unclear on the applicability of measures of stiffness and the use of spinal x-rays. The evidence was of mixed quality, but unfavourable for the use of manual muscle testing, skin conductance, surface electromyography and skin temperature measurement. Conclusions A considerable range of methods is in use for determining where in the spine to administer spinal manipulation. The currently published evidence falls across a spectrum ranging from strongly favourable to strongly unfavourable in regard to using these methods. In general, the stronger and more favourable evidence is for those procedures which take a direct measure of the presumptive site of care– methods involving pain provocation upon palpation or localized tissue examination. Procedures which involve some indirect assessment for identifying the manipulable lesion of the spine–such as skin conductance or thermography–tend not to be supported by the available evidence. PMID:24499598

  18. Next generation diagnostic molecular pathology: critical appraisal of quality assurance in Europe.

    PubMed

    Dubbink, Hendrikus J; Deans, Zandra C; Tops, Bastiaan B J; van Kemenade, Folkert J; Koljenović, S; van Krieken, Han J M; Blokx, Willeke A M; Dinjens, Winand N M; Groenen, Patricia J T A

    2014-06-01

    Tumor evaluation in pathology is more and more based on a combination of traditional histopathology and molecular analysis. Due to the rapid development of new cancer treatments that specifically target aberrant proteins present in tumor cells, treatment decisions are increasingly based on the molecular features of the tumor. Not only the number of patients eligible for targeted precision medicine, but also the number of molecular targets per patient and tumor type is rising. Diagnostic molecular pathology, the discipline that determines the molecular aberrations present in tumors for diagnostic, prognostic or predictive purposes, is faced with true challenges. The laboratories have to meet the need of comprehensive molecular testing using only limited amount of tumor tissue, mostly fixed in formalin and embedded in paraffin (FFPE), in short turnaround time. Choices must be made for analytical methods that provide accurate, reliable and cost-effective results. Validation of the test procedures and results is essential. In addition, participation and good performance in internal (IQA) and external quality assurance (EQA) schemes is mandatory. In this review, we critically evaluate the validation procedure for comprehensive molecular tests as well as the organization of quality assurance and assessment of competence of diagnostic molecular pathology laboratories within Europe. Copyright © 2014 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  19. A general diagnostic model applied to language testing data.

    PubMed

    von Davier, Matthias

    2008-11-01

    Probabilistic models with one or more latent variables are designed to report on a corresponding number of skills or cognitive attributes. Multidimensional skill profiles offer additional information beyond what a single test score can provide, if the reported skills can be identified and distinguished reliably. Many recent approaches to skill profile models are limited to dichotomous data and have made use of computationally intensive estimation methods such as Markov chain Monte Carlo, since standard maximum likelihood (ML) estimation techniques were deemed infeasible. This paper presents a general diagnostic model (GDM) that can be estimated with standard ML techniques and applies to polytomous response variables as well as to skills with two or more proficiency levels. The paper uses one member of a larger class of diagnostic models, a compensatory diagnostic model for dichotomous and partial credit data. Many well-known models, such as univariate and multivariate versions of the Rasch model and the two-parameter logistic item response theory model, the generalized partial credit model, as well as a variety of skill profile models, are special cases of this GDM. In addition to an introduction to this model, the paper presents a parameter recovery study using simulated data and an application to real data from the field test for TOEFL Internet-based testing.

  20. Comparison of the quadratic configuration interaction and coupled cluster approaches to electron correlation including the effect of triple excitations

    NASA Technical Reports Server (NTRS)

    Taylor, Peter R.; Lee, Timothy J.; Rendell, Alistair P.

    1990-01-01

    The recently proposed quadratic configuration interaction (QCI) method is compared with the more rigorous coupled cluster (CC) approach for a variety of chemical systems. Some of these systems are well represented by a single-determinant reference function and others are not. The finite order singles and doubles correlation energy, the perturbational triples correlation energy, and a recently devised diagnostic for estimating the importance of multireference effects are considered. The spectroscopic constants of CuH, the equilibrium structure of cis-(NO)2 and the binding energies of Be3, Be4, Mg3, and Mg4 were calculated using both approaches. The diagnostic for estimating multireference character clearly demonstrates that the QCI method becomes less satisfactory than the CC approach as non-dynamical correlation becomes more important, in agreement with a perturbational analysis of the two methods and the numerical estimates of the triple excitation energies they yield. The results for CuH show that the differences between the two methods become more apparent as the chemical systems under investigation becomes more multireference in nature and the QCI results consequently become less reliable. Nonetheless, when the system of interest is dominated by a single reference determinant both QCI and CC give very similar results.

  1. Independent value of image fusion in unenhanced breast MRI using diffusion-weighted and morphological T2-weighted images for lesion characterization in patients with recently detected BI-RADS 4/5 x-ray mammography findings.

    PubMed

    Bickelhaupt, Sebastian; Tesdorff, Jana; Laun, Frederik Bernd; Kuder, Tristan Anselm; Lederer, Wolfgang; Teiner, Susanne; Maier-Hein, Klaus; Daniel, Heidi; Stieber, Anne; Delorme, Stefan; Schlemmer, Heinz-Peter

    2017-02-01

    The aim of this study was to evaluate the accuracy and applicability of solitarily reading fused image series of T2-weighted and high-b-value diffusion-weighted sequences for lesion characterization as compared to sequential or combined image analysis of these unenhanced sequences and to contrast- enhanced breast MRI. This IRB-approved study included 50 female participants with suspicious breast lesions detected in screening X-ray mammograms, all of which provided written informed consent. Prior to biopsy, all women underwent MRI including diffusion-weighted imaging (DWIBS, b = 1500s/mm 2 ). Images were analyzed as follows: prospective image fusion of DWIBS and T2-weighted images (FU), side-by-side analysis of DWIBS and T2-weighted series (CO), combination of the first two methods (CO+FU), and full contrast-enhanced diagnostic protocol (FDP). Diagnostic indices, confidence, and image quality of the protocols were compared by two blinded readers. Reading the CO+FU (accuracy 0.92; NPV 96.1 %; PPV 87.6 %) and the CO series (0.90; 96.1 %; 83.7 %) provided a diagnostic performance similar to the FDP (0.95; 96.1 %; 91.3 %; p > 0.05). FU reading alone significantly reduced the diagnostic accuracy (0.82; 93.3 %; 73.4 %; p = 0.023). MR evaluation of suspicious BI-RADS 4 and 5 lesions detected on mammography by using a non-contrast-enhanced T2-weighted and DWIBS sequence protocol is most accurate if MR images were read using the CO+FU protocol. • Unenhanced breast MRI with additional DWIBS/T2w-image fusion allows reliable lesion characterization. • Abbreviated reading of fused DWIBS/T2w-images alone decreases diagnostic confidence and accuracy. • Reading fused DWIBS/T2w-images as the sole diagnostic method should be avoided.

  2. Performance of a real-time PCR assay in routine bovine mastitis diagnostics compared with in-depth conventional culture.

    PubMed

    Hiitiö, Heidi; Riva, Rauna; Autio, Tiina; Pohjanvirta, Tarja; Holopainen, Jani; Pyörälä, Satu; Pelkonen, Sinikka

    2015-05-01

    Reliable identification of the aetiological agent is crucial in mastitis diagnostics. Real-time PCR is a fast, automated tool for detecting the most common udder pathogens directly from milk. In this study aseptically taken quarter milk samples were analysed with a real-time PCR assay (Thermo Scientific PathoProof Mastitis Complete-12 Kit, Thermo Fisher Scientific Ltd.) and by semi-quantitative, in-depth bacteriological culture (BC). The aim of the study was to evaluate the diagnostic performance of the real-time PCR assay in routine use. A total of 294 quarter milk samples from routine mastitis cases were cultured in the national reference laboratory of Finland and examined with real-time PCR. With BC, 251 out of 294 (85.7%) of the milk samples had at least one colony on the plate and 38 samples were considered contaminated. In the PCR mastitis assay, DNA of target species was amplified in 244 samples out of 294 (83.0%). The most common bacterial species detected in the samples, irrespective of the diagnostic method, was the coagulase negative staphylococci (CNS) group (later referred as Staphylococcus spp.) followed by Staphylococcus aureus. Sensitivity (Se) and specificity (Sp) for the PCR assay to provide a positive Staph. aureus result was 97.0 and 95.8% compared with BC. For Staphylococcus spp., the corresponding figures were 86.7 and 75.4%. Our results imply that PCR performed well as a diagnostic tool to detect Staph. aureus but may be too nonspecific for Staphylococcus spp. in routine use with the current cut-off Ct value (37.0). Using PCR as the only microbiological method for mastitis diagnostics, clinical relevance of the results should be carefully considered before further decisions, for instance antimicrobial treatment, especially when minor pathogens with low amount of DNA have been detected. Introducing the concept of contaminated samples should also be considered.

  3. Diagnostic performance of different measurement methods for lung nodule enhancement at quantitative contrast-enhanced computed tomography

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Klotz, Ernst; Dregger, Uwe; Beyer, Florian; Heindel, Walter

    2004-05-01

    Lack of angiogenesis virtually excludes malignancy of a pulmonary nodule; assessment with quantitative contrast-enhanced CT (QECT) requires a reliable enhancement measurement technique. Diagnostic performance of different measurement methods in the distinction between malignant and benign nodules was evaluated. QECT (unenhanced scan and 4 post-contrast scans) was performed in 48 pulmonary nodules (12 malignant, 12 benign, 24 indeterminate). Nodule enhancement was the difference between the highest nodule density at any post-contrast scan and the unenhanced scan. Enhancement was determined with: A) the standard 2D method; B) a 3D method consisting of segmentation, removal of peripheral structures and density averaging. Enhancement curves were evaluated for their plausibility using a predefined set of criteria. Sensitivity and specificity were 100% and 33% for the 2D method resp. 92% and 55% for the 3D method using a threshold of 20 HU. One malignant nodule did not show significant enhancement with method B due to adjacent atelectasis which disappeared within the few minutes of the QECT examination. Better discrimination between benign and malignant lesions was achieved with a slightly higher threshold than proposed in the literature. Application of plausibility criteria to the enhancement curves rendered less plausibility faults with the 3D method. A new 3D method for analysis of QECT scans yielded less artefacts and better specificity in the discrimination between benign and malignant pulmonary nodules when using an appropriate enhancement threshold. Nevertheless, QECT results must be interpreted with care.

  4. The reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a German general practice population sample.

    PubMed

    Dybek, Inga; Bischof, Gallus; Grothues, Janina; Reinhardt, Susa; Meyer, Christian; Hapke, Ulfert; John, Ulrich; Broocks, Andreas; Hohagen, Fritz; Rumpf, Hans-Jürgen

    2006-05-01

    Our goal was to analyze the retest reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a primary-care setting and recommend a cut-off value for the different alcohol-related diagnoses. Participants recruited from general practices (GPs) in two northern German cities received the AUDIT, which was embedded in a health-risk questionnaire. In total, 10,803 screenings were conducted. The retest reliability was tested on a subsample of 99 patients, with an intertest interval of 30 days. Sensitivity and specificity at a number of different cut-off values were estimated for the sample of alcohol consumers (n=8237). For this study, 1109 screen-positive patients received a diagnostic interview. Individuals who scored less than five points in the AUDIT and also tested negative in a second alcohol-related screen were defined as "negative" (n=6003). This definition was supported by diagnostic interviews of 99 screen-negative patients from which no false negatives could be detected. As the gold standard for detection of an alcohol-use disorder (AUD), we used the Munich-Composite International Diagnostic Interview (MCIDI), which is based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria. On the item level, the reliability, measured by the intraclass correlation coefficient (ICC), ranged between .39 (Item 9) and .98 (Item 10). For the total score, the ICC was .95. For cut-off values of eight points and five points, 87.5% and 88.9%, respectively, of the AUDIT-positives, and 98.9% and 95.1%, respectively, of the AUDIT-negatives were identically identified at retest, with kappa = .86 and kappa = .81. At the cut-off value of five points, we determined good combinations of sensitivity and specificity for the following diagnoses: alcohol dependence (sensitivity and specificity of .97 and .88, respectively), AUD (.97 and .92), and AUD and/or at-risk consumption (.97 and .91). Embedded in a health-risk questionnaire in primary-care settings, the AUDIT is a reliable and valid screening instrument to identify at-risk drinkers and patients with an AUD. Our findings strongly suggest a lowering of the recommended cut-off value of eight points.

  5. Convergent Validity of the Autism Spectrum Disorder-Diagnostic for Children (ASD-DC) and Childhood Autism Rating Scales (CARS)

    ERIC Educational Resources Information Center

    Matson, Johnny L.; Mahan, Sara; Hess, Julie A.; Fodstad, Jill C.; Neal, Daniene

    2010-01-01

    Previous studies analyzed the reliability as well as sensitivity and specificity of the Autism Spectrum Disorder-Diagnostic for Children (ASD-DC). This study further examines the psychometric properties of the ASD-DC by assessing whether the ASD-DC has convergent validity against a psychometrically sound observational instrument for Autistic…

  6. Molecular detection of Plasmodium knowlesi in a Dutch traveler by real-time PCR.

    PubMed

    Link, Lonneke; Bart, Aldert; Verhaar, Nienke; van Gool, Tom; Pronk, Marjolijn; Scharnhorst, Volkher

    2012-07-01

    Plasmodium knowlesi infection with low parasitemia presents a diagnostic challenge, as rapid diagnostic tests are often negative and identification to the species level by microscopy is difficult. P. knowlesi malaria in a traveler is described, and real-time PCR is demonstrated to support fast and reliable diagnosis and identification to the species level.

  7. Variola Virus-Specific Diagnostic Assays: Characterization, Sensitivity, and Specificity

    PubMed Central

    Kondas, Ashley V.; Olson, Victoria A.; Li, Yu; Abel, Jason; Laker, Miriam; Rose, Laura; Wilkins, Kimberly; Turner, Jonathan; Kline, Richard

    2015-01-01

    A public health response relies upon rapid and reliable confirmation of disease by diagnostic assays. Here, we detail the design and validation of two variola virus-specific real-time PCR assays, since previous assays cross-reacted with newly identified cowpox viruses. The assay specificity must continually be reassessed as other closely related viruses are identified. PMID:25673790

  8. Brief Report: Autism in Individuals with Down Syndrome

    ERIC Educational Resources Information Center

    Starr, Elizabeth M.; Berument, Sibel Kazak; Tomlins, Megan; Papanikolaou, Katerina; Rutter, Michael

    2005-01-01

    As an off-shoot of a study examining the reliability and validity of an adapted version of the Pre-Linguistic Autism Diagnostic Observation Schedule (A-PL-ADOS), 13 individuals with Down syndrome with IQs ranging between 24 and 48 were administered the Autism Diagnostic Interview-Revised (ADI-R) and the A-PL-ADOS, which are well-validated…

  9. Fix-Forward: A Comparison of the Army’s Requirements and Capabilities for Forward Support Maintenance,

    DTIC Science & Technology

    1983-04-01

    tolerances or spaci - able assets diagnostic/fault ness float fications isolation devices Operation of cannibalL- zation point Why Sustain materiel...with diagnostic software based on "fault tree " representation of the M65 ThS) to bridge the gap in diagnostics capability was demonstrated in 1980 and... identification friend or foe) which has much lower reliability than TSQ-73 peculiar hardware). Thus, as in other examples, reported readiness does not reflect

  10. A reliable sewage quality abnormal event monitoring system.

    PubMed

    Li, Tianling; Winnel, Melissa; Lin, Hao; Panther, Jared; Liu, Chang; O'Halloran, Roger; Wang, Kewen; An, Taicheng; Wong, Po Keung; Zhang, Shanqing; Zhao, Huijun

    2017-09-15

    With closing water loop through purified recycled water, wastewater becomes a part of source water, requiring reliable wastewater quality monitoring system (WQMS) to manage wastewater source and mitigate potential health risks. However, the development of reliable WQMS is fatally constrained by severe contamination and biofouling of sensors due to the hostile analytical environment of wastewaters, especially raw sewages, that challenges the limit of existing sensing technologies. In this work, we report a technological solution to enable the development of WQMS for real-time abnormal event detection with high reliability and practicality. A vectored high flow hydrodynamic self-cleaning approach and a dual-sensor self-diagnostic concept are adopted for WQMS to effectively encounter vital sensor failing issues caused by contamination and biofouling and ensure the integrity of sensing data. The performance of the WQMS has been evaluated over a 3-year trial period at different sewage catchment sites across three Australian states. It has demonstrated that the developed WQMS is capable of continuously operating in raw sewage for a prolonged period up to 24 months without maintenance and failure, signifying the high reliability and practicality. The demonstrated WQMS capability to reliably acquire real-time wastewater quality information leaps forward the development of effective wastewater source management system. The reported self-cleaning and self-diagnostic concepts should be applicable to other online water quality monitoring systems, opening a new way to encounter the common reliability and stability issues caused by sensor contamination and biofouling. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Can autism be diagnosed accurately in children under 3 years?

    PubMed

    Stone, W L; Lee, E B; Ashford, L; Brissie, J; Hepburn, S L; Coonrod, E E; Weiss, B H

    1999-02-01

    This study investigated the reliability and stability of an autism diagnosis in children under 3 years of age who received independent diagnostic evaluations from two clinicians during two consecutive yearly evaluations. Strong evidence for the reliability and stability of the diagnosis was obtained. Diagnostic agreement between clinicians was higher for the broader discrimination of autism spectrum vs. no autism spectrum than for the more specific discrimination of autism vs. PDD-NOS. The diagnosis of autism at age 2 was more stable than the diagnosis of PDD-NOS at the same age. Social deficits and delays in spoken language were the most prominent DSM-IV characteristics evidenced by very young children with autism.

  12. A novel approach on accelerated ageing towards reliability optimization of high concentration photovoltaic cells

    NASA Astrophysics Data System (ADS)

    Tsanakas, John A.; Jaffre, Damien; Sicre, Mathieu; Elouamari, Rachid; Vossier, Alexis; de Salins, Jean-Edouard; Bechou, Laurent; Levrier, Bruno; Perona, Arnaud; Dollet, Alain

    2014-09-01

    This paper presents a preliminary study upon a novel approach proposed for highly accelerated ageing and reliability optimization of high concentrating photovoltaic (HCPV) cells and assemblies. The intended approach aims to overcome several limitations of some current accelerated ageing tests (AAT) adopted up today, proposing the use of an alternative experimental set-up for performing faster and more realistic thermal cycles, under real sun, without the involvement of environmental chamber. The study also includes specific characterization techniques, before and after each AAT sequence, which respectively provide the initial and final diagnosis on the condition of the tested sample. The acquired data from these diagnostic/characterization methods are then used as indices to determine both quantitatively and qualitatively the severity of degradation and, thus, the ageing level for each tested HCPV assembly or cell sample. Ultimate goal of such "initial diagnosis - AAT - final diagnosis" sequences is to provide the basis for a future work on the reliability analysis of the main degradation mechanisms and confident prediction of failure propagation in HCPV cells, by means of acceleration factor (AF) and mean-time-to-failure (MTTF) estimations.

  13. Chromosome-specific staining to detect genetic rearrangements

    DOEpatents

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas; Westbrook, Carol

    2013-04-09

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  14. Introducing the Filtered Park's and Filtered Extended Park's Vector Approach to detect broken rotor bars in induction motors independently from the rotor slots number

    NASA Astrophysics Data System (ADS)

    Gyftakis, Konstantinos N.; Marques Cardoso, Antonio J.; Antonino-Daviu, Jose A.

    2017-09-01

    The Park's Vector Approach (PVA), together with its variations, has been one of the most widespread diagnostic methods for electrical machines and drives. Regarding the broken rotor bars fault diagnosis in induction motors, the common practice is to rely on the width increase of the Park's Vector (PV) ring and then apply some more sophisticated signal processing methods. It is shown in this paper that this method can be unreliable and is strongly dependent on the magnetic poles and rotor slot numbers. To overcome this constraint, the novel Filtered Park's/Extended Park's Vector Approach (FPVA/FEPVA) is introduced. The investigation is carried out with FEM simulations and experimental testing. The results prove to satisfyingly coincide, whereas the proposed advanced FPVA method is desirably reliable.

  15. Molecular Signature of Indeterminate Thyroid Lesions: Current Methods to Improve Fine Needle Aspiration Cytology (FNAC) Diagnosis

    PubMed Central

    Cantara, Silvia; Marzocchi, Carlotta; Pilli, Tania; Cardinale, Sandro; Forleo, Raffaella; Castagna, Maria Grazia; Pacini, Furio

    2017-01-01

    Fine needle aspiration cytology (FNAC) represents the gold standard for determining the nature of thyroid nodules. It is a reliable method with good sensitivity and specificity. However, indeterminate lesions remain a diagnostic challenge and researchers have contributed molecular markers to search for in cytological material to refine FNAC diagnosis and avoid unnecessary surgeries. Nowadays, several “home-made” methods as well as commercial tests are available to investigate the molecular signature of an aspirate. Moreover, other markers (i.e., microRNA, and circulating tumor cells) have been proposed to discriminate benign from malignant thyroid lesions. Here, we review the literature and provide data from our laboratory on mutational analysis of FNAC material and circulating microRNA expression obtained in the last 6 years. PMID:28383480

  16. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartlein, Rick; Hampton, Nigel; Perkel, Josh

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach asmore » a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.« less

  17. Early diagnosis of dengue in travelers: comparison of a novel real-time RT-PCR, NS1 antigen detection and serology.

    PubMed

    Huhtamo, Eili; Hasu, Essi; Uzcátegui, Nathalie Y; Erra, Elina; Nikkari, Simo; Kantele, Anu; Vapalahti, Olli; Piiparinen, Heli

    2010-01-01

    The increased traveling to dengue endemic regions and the numerous epidemics have led to a rise in imported dengue. The laboratory diagnosis of acute dengue requires several types of tests and often paired samples are needed for obtaining reliable results. Although several diagnostic methods are available, proper comparative data on their performance are lacking. To compare the performance of novel methods including a novel pan-DENV real-time RT-PCR and a commercially available NS1 capture-EIA in regard to IgM detection for optimizing the early diagnosis of DENV in travelers. A panel of 99 selected early phase serum samples of dengue patients was studied by real-time RT-PCR, NS1 antigen ELISA, IgM-EIA, IgG-IFA and cell culture virus isolation. The novel real-time RT-PCR was shown specific and sensitive for detection of DENV-1-4 RNA and suitable for diagnostic use. The diagnostic rate using combination of RNA and IgM detection was 99% and using NS1 and IgM detection 95.9%. The results of RNA and NS1 antigen detection disagreed in 15.5% of samples that had only RNA or NS1 antigen detected. The diagnostic rates of early samples are higher when either RNA or NS1 antigen detection is combined with IgM detection. Besides the differences in the RNA and NS1 detection assays, the observed discrepancy of results could suggest individual variation or differences in timing of these markers in patient serum. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  18. ``The perceptual bases of speaker identity'' revisited

    NASA Astrophysics Data System (ADS)

    Voiers, William D.

    2003-10-01

    A series of experiments begun 40 years ago [W. D. Voiers, J. Acoust. Soc. Am. 36, 1065-1073 (1964)] was concerned with identifying the perceived voice traits (PVTs) on which human recognition of voices depends. It culminated with the development of a voice taxonomy based on 20 PVTs and a set of highly reliable rating scales for classifying voices with respect to those PVTs. The development of a perceptual voice taxonomy was motivated by the need for a practical method of evaluating speaker recognizability in voice communication systems. The Diagnostic Speaker Recognition Test (DSRT) evaluates the effects of systems on speaker recognizability as reflected in changes in the inter-listener reliability of voice ratings on the 20 PVTs. The DSRT thus provides a qualitative, as well as quantitative, evaluation of the effects of a system on speaker recognizability. A fringe benefit of this project is PVT rating data for a sample of 680 voices. [Work partially supported by USAFRL.

  19. [Multi-centre clinical assessment of the Russian language version of the Diagnostic Interview for Psychoses].

    PubMed

    Smirnova, D A; Petrova, N N; Pavlichenko, A V; Martynikhin, I A; Dorofeikova, M V; Eremkin, V I; Izmailova, O V; Osadshiy, Yu Yu; Romanov, D V; Ubeikon, D A; Fedotov, I A; Sheifer, M S; Shustov, A D; Yashikhina, A A; Clark, M; Badcock, J; Watterreus, A; Morgan, V; Jablensky, A

    2018-01-01

    The Diagnostic Interview for Psychoses (DIP) was developed to enhance the quality of diagnostic assessment of psychotic disorders. The aim of the study was the adaptation of the Russian language version and evaluation of its validity and reliability. Ninety-eight patients with psychotic disorders (89 video recordings) were assessed by 12 interviewers using the Russian version of DIP at 7 clinical sites (in 6 cities of the Russian Federation). DIP ratings on 32 cases of a randomized case sample were made by 9 interviewers and the inter-rater reliability was compared with the researchers' DIP ratings. Overall pairwise agreement and Cohen's kappa were calculated. Diagnostic validity was evaluated on the basis of comparing the researchers' ratings using the Russian version of DIP with the 'gold standard' ratings of the same 62 clinical cases from the Western Australia Family Study Schizophrenia (WAFSS). The mean duration of the interview was 47±21 minutes. The Kappa statistic demonstrated a significant or almost perfect level of agreement on the majority of DIP items (84.54%) and a significant agreement for the ICD-10 diagnoses generated by the DIP computer diagnostic algorithm (κ=0.68; 95% CI 0.53,0.93). The level of agreement on the researchers' diagnoses was considerably lower (κ=0.31; 95% CI 0.06,0.56). The agreement on affective and positive psychotic symptoms was significantly higher than agreement on negative symptoms (F(2,44)=20.72, p<0.001, η2=0.485). The diagnostic validity of the Russian language version of DIP was confirmed by 73% (45/62) of the Russian DIP diagnoses matching the original WAFSS diagnoses. Among the mismatched diagnoses were 80 cases with a diagnosis of F20 Schizophrenia in the medical documentation compared to the researchers' F20 diagnoses in only 68 patients and in 62 of the DIP computerized diagnostic outputs. The reported level of subjective difficulties experienced when using the DIP was low to moderate. The results of the study confirm the validity and reliability of the Russian version of the DIP for evaluating psychotic disorders. DIP can be recommended for use in education and training, clinical practice and research as an important diagnostic resource.

  20. Radiological interpretation of images displayed on tablet computers: a systematic review.

    PubMed

    Caffery, L J; Armfield, N R; Smith, A C

    2015-06-01

    To review the published evidence and to determine if radiological diagnostic accuracy is compromised when images are displayed on a tablet computer and thereby inform practice on using tablet computers for radiological interpretation by on-call radiologists. We searched the PubMed and EMBASE databases for studies on the diagnostic accuracy or diagnostic reliability of images interpreted on tablet computers. Studies were screened for inclusion based on pre-determined inclusion and exclusion criteria. Studies were assessed for quality and risk of bias using Quality Appraisal of Diagnostic Reliability Studies or the revised Quality Assessment of Diagnostic Accuracy Studies tool. Treatment of studies was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). 11 studies met the inclusion criteria. 10 of these studies tested the Apple iPad(®) (Apple, Cupertino, CA). The included studies reported high sensitivity (84-98%), specificity (74-100%) and accuracy rates (98-100%) for radiological diagnosis. There was no statistically significant difference in accuracy between a tablet computer and a digital imaging and communication in medicine-calibrated control display. There was a near complete consensus from authors on the non-inferiority of diagnostic accuracy of images displayed on a tablet computer. All of the included studies were judged to be at risk of bias. Our findings suggest that the diagnostic accuracy of radiological interpretation is not compromised by using a tablet computer. This result is only relevant to the Apple iPad and to the modalities of CT, MRI and plain radiography. The iPad may be appropriate for an on-call radiologist to use for radiological interpretation.

Top