Sample records for reliable screening methods

  1. Evaluation of hydrate-screening methods.

    PubMed

    Cui, Yong; Yao, Erica

    2008-07-01

    The purpose of this work is to evaluate the effectiveness and reliability of several common hydrate-screening techniques, and to provide guidelines for designing hydrate-screening programs for new drug candidates. Ten hydrate-forming compounds were selected as model compounds and six hydrate-screening approaches were applied to these compounds in an effort to generate their hydrate forms. The results prove that no screening approach is universally effective in finding hydrates for small organic compounds. Rather, a combination of different methods should be used to improve screening reliability. Among the approaches tested, the dynamic water vapor sorption/desorption isotherm (DVI) method and storage under high humidity (HH) yielded 60-70% success ratios, the lowest among all techniques studied. The risk of false negatives arises in particular for nonhygroscopic compounds. On the other hand, both slurry in water (Slurry) and temperature cycling of aqueous suspension (TCS) showed high success rates (90%) with some exceptions. The mixed solvent systems (MSS) procedure also achieved high success rates (90%), and was found to be more suitable for water-insoluble compounds. For water-soluble compounds, MSS may not be the best approach because recrystallization is difficult in solutions with high water activity. Finally, vapor diffusion (VD) yielded a reasonably high success ratio in finding hydrates (80%). However, this method suffers from experimental difficulty and unreliable results for either highly water-soluble or water-insoluble compounds. This study indicates that a reliable hydrate-screening strategy should take into consideration the solubility and hygroscopicity of the compounds studied. A combination of the Slurry or TCS method with the MSS procedure could provide a screening strategy with reasonable reliability.

  2. [Reliability and validity of warning signs checklist for screening psychological, behavioral and developmental problems of children].

    PubMed

    Huang, X N; Zhang, Y; Feng, W W; Wang, H S; Cao, B; Zhang, B; Yang, Y F; Wang, H M; Zheng, Y; Jin, X M; Jia, M X; Zou, X B; Zhao, C X; Robert, J; Jing, Jin

    2017-06-02

    Objective: To evaluate the reliability and validity of warning signs checklist developed by the National Health and Family Planning Commission of the People's Republic of China (NHFPC), so as to determine the screening effectiveness of warning signs on developmental problems of early childhood. Method: Stratified random sampling method was used to assess the reliability and validity of checklist of warning sign and 2 110 children 0 to 6 years of age(1 513 low-risk subjects and 597 high-risk subjects) were recruited from 11 provinces of China. The reliability evaluation for the warning signs included the test-retest reliability and interrater reliability. With the use of Age and Stage Questionnaire (ASQ) and Gesell Development Diagnosis Scale (GESELL) as the criterion scales, criterion validity was assessed by determining the correlation and consistency between the screening results of warning signs and the criterion scales. Result: In terms of the warning signs, the screening positive rates at different ages ranged from 10.8%(21/141) to 26.2%(51/137). The median (interquartile) testing time for each subject was 1(0.6) minute. Both the test-retest reliability and interrater reliability of warning signs reached 0.7 or above, indicating that the stability was good. In terms of validity assessment, there was remarkable consistency between ASQ and warning signs, with the Kappa value of 0.63. With the use of GESELL as criterion, it was determined that the sensitivity of warning signs in children with suspected developmental delay was 82.2%, and the specificity was 77.7%. The overall Youden index was 0.6. Conclusion: The reliability and validity of warning signs checklist for screening early childhood developmental problems have met the basic requirements of psychological screening scales, with the characteristics of short testing time and easy operation. Thus, this warning signs checklist can be used for screening psychological and behavioral problems of early childhood, especially in community settings.

  3. An Efficient Variable Screening Method for Effective Surrogate Models for Reliability-Based Design Optimization

    DTIC Science & Technology

    2014-04-01

    surrogate model generation is difficult for high -dimensional problems, due to the curse of dimensionality. Variable screening methods have been...a variable screening model was developed for the quasi-molecular treatment of ion-atom collision [16]. In engineering, a confidence interval of...for high -level radioactive waste [18]. Moreover, the design sensitivity method can be extended to the variable screening method because vital

  4. Conditional Reliability and the Identification of Communities

    DTIC Science & Technology

    2009-11-09

    screening is needed to find the factors and interactions that may be relevant. This problem arises in numerous different settings : screening using D...related to the core communities than to each other. and 4. Develop a set of computational methods for conditional reliability. A report describing...resilience address the question: What is the probability that k nodes can communicate? The difference is that for k-terminal reliability, the k communicating

  5. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  6. Measurement methods to assess diastasis of the rectus abdominis muscle (DRAM): A systematic review of their measurement properties and meta-analytic reliability generalisation.

    PubMed

    van de Water, A T M; Benjamin, D R

    2016-02-01

    Systematic literature review. Diastasis of the rectus abdominis muscle (DRAM) has been linked with low back pain, abdominal and pelvic dysfunction. Measurement is used to either screen or to monitor DRAM width. Determining which methods are suitable for screening and monitoring DRAM is of clinical value. To identify the best methods to screen for DRAM presence and monitor DRAM width. AMED, Embase, Medline, PubMed and CINAHL databases were searched for measurement property studies of DRAM measurement methods. Population characteristics, measurement methods/procedures and measurement information were extracted from included studies. Quality of all studies was evaluated using 'quality rating criteria'. When possible, reliability generalisation was conducted to provide combined reliability estimations. Thirteen studies evaluated measurement properties of the 'finger width'-method, tape measure, calipers, ultrasound, CT and MRI. Ultrasound was most evaluated. Methodological quality of these studies varied widely. Pearson's correlations of r = 0.66-0.79 were found between calipers and ultrasound measurements. Calipers and ultrasound had Intraclass Correlation Coefficients (ICC) of 0.78-0.97 for test-retest, inter- and intra-rater reliability. The 'finger width'-method had weighted Kappa's of 0.73-0.77 for test-retest reliability, but moderate agreement (63%; weighted Kappa = 0.53) between raters. Comparing calipers and ultrasound, low measurement error was found (above the umbilicus), and the methods had good agreement (83%; weighted Kappa = 0.66) for discriminative purposes. The available information support ultrasound and calipers as adequate methods to assess DRAM. For other methods limited measurement information of low to moderate quality is available and further evaluation of their measurement properties is required. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  8. The Columbia SuicideScreen: Validity and Reliability of a Screen for Youth Suicide and Depression.

    ERIC Educational Resources Information Center

    Shaffer, David; Scott, Michelle; Wilcox, Holly; MasLow, Carey; Hicks, Roger; Lucas, Christopher P.; Garfinkel, Robin; Greenwald, Steven

    2004-01-01

    Objective: This study reports on the psychometric properties of a brief, self-administered screening questionnaire, the Columbia SuicideScreen[R] (CSS), intended to identify high school students at risk for suicide. Method: Seventeen hundred twenty-nine 9th- to 12th-grade students completed the CSS and Beck Depression Inventory during school hours…

  9. Validity, efficacy and reliability of 3 nutritional screening tools regarding the nutritional assessment in different social and health areas.

    PubMed

    Castro-Vega, Iciar; Veses Martín, Silvia; Cantero Llorca, Juana; Barrios Marta, Cristina; Bañuls, Celia; Hernández-Mijares, Antonio

    2018-03-09

    Nutritional screening allows for the detection of nutritional risk. Validated tools should be implemented, and their usefulness should be contrasted with a gold standard. The aim of this study is to discover the validity, efficacy and reliability of 3 nutritional screening tools in relation to complete nutritional assessment. A sub-analysis of a cross-sectional and descriptive study on the prevalence of disease-related malnutrition. The sample was selected from outpatients, hospitalized and institutionalized patients. MUST, MNAsf and MST screening were employed. A nutritional assessment of all the patients was undertaken. The SENPE-SEDOM consensus was used for the diagnosis. In the outpatients, both MUST and MNAsf have a similar validity in relation to the nutritional assessment (AUC 0.871 and 0.883, respectively). In the institutionalized patients, the MUST screening method is the one that shows the greatest validity (AUC 0.815), whereas in the hospitalized patients, the most valid methods are both MUST and MST (AUC 0.868 and 0.853, respectively). It is essential to use nutritional screening to invest the available resources wisely. Based on our results, MUST is the most suitable screening method in hospitalized and institutionalized patients. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  10. ["Allergic Progression": importance of Phadiatop and RAST fx5 as screening measures for childhood atopy].

    PubMed

    Molkhou, P

    1999-04-01

    Since discovery of IgE in 1967, which was a real revolution in allergy field, new biological methods as Phadiatop for inhalant allergens and RAST fx5 for food allergens, have been used routinely. Both methods are very useful for reliable and cost efficient atopy screening.

  11. Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes.

    PubMed

    Bernalte, E; Marín Sánchez, C; Pinilla Gil, E

    2011-03-09

    The applicability of commercial screen-printed gold electrodes (SPGEs) for the determination of Hg(II) in ambient water samples by square wave anodic stripping voltammetry has been demonstrated. Electrode conditioning procedures, chemical and instrumental variables have been optimized to develop a reliable method capable of measuring dissolved mercury in the low ng mL(-1) range (detection limit 1.1 ng mL(-1)), useful for pollution monitoring or screening purposes. The proposed method was tested with the NIST 1641d Mercury in Water Standard Reference Material (recoveries 90.0-110%) and the NCS ZC 76303 Mercury in Water Certified Reference Material (recoveries 82.5-90.6%). Waste water samples from industrial origin and fortified rain water samples were assayed for mercury by the proposed method and by a reference ICP-MS method, with good agreement. Screen printing technology thus opens a useful way for the construction of reliable electrochemical sensors for decentralized or even field Hg(II) testing. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Rapid and reliable determination of illegal adulterant in herbal medicines and dietary supplements by LC/MS/MS.

    PubMed

    Liang, Qionglin; Qu, Jun; Luo, Guoan; Wang, Yiming

    2006-02-13

    In recent years, dietary supplements and herbal medicines are increasing in popularity all over the world. However, it is problematic that some manufacturers illegally included synthetic drugs in their products. Due to the extremely complex matrices of those products, most existing methods for screening illegal adulterations are time-consuming and liable to false positive. In this paper, a robust LC/MS/MS method for the high-throughput, sensitive and reliable determination of illegal adulterations from herbal medicines and dietary supplements was established. Minimal LC separation was employed and MRM was used to simultaneously monitor the three transitions under their respective optimal collision energy for each compound. Positive results were determined only if well-defined peaks appeared at all of the three transitions and the ratios among the peak areas were within given threshold. In this study, the method had been applied for the screening of nine most commonly adulterated therapeutic substances, such as sildenafil (Viagra) and famotidine, and the lower limits of detection of these compounds ranged from 0.05 to 1.5 ng/ml. Little sample preparation was needed for this method and the analysis time was less than 5 min/sample. The reliability has been demonstrated by the test with blank matrix. Over 200 products that were under suspicion by SDA of China had been assayed and till now no false negative or positive result was found. This method is rapid, simple, reliable and capable of screening multiple adulterants in one run.

  13. EVALUATION OF LITERATURE ESTABLISHING SCREENING LEVELS FOR TERRESTRIAL PLANTS/INVERTEBRATES

    EPA Science Inventory

    Scientific publications often lack key information on experimental design or do not follow appropriate test methods and therefore cannot be used in deriving reliable benchmarks. Risk based soil screening levels (Eco-SSLs) are being established for chemicals of concern to terrestr...

  14. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.

    PubMed

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent sessions. Conclusion: The game-based assessment for cognitive screening has relatively strong test-retest reliability and little evidence of practice effects among elderly emergency patients, and may be a useful supplement to existing cognitive assessment methods.

  15. Expression of human peroxisome proliferator-activated receptors ligand binding domain-maltose binding protein fusion protein in Escherichia coli: a convenient and reliable method for preparing receptor for screening ligands.

    PubMed

    Li, Changqing; Tian, Mi; Yuan, Ye; Zhou, Qinxin

    2008-12-01

    Human peroxisome proliferator-activated receptors (hPPARs) are ligand-activated transcription factors and are the target for the treatment of many diseases. Screening of their ligands is mainly based on assays of ligand binding to the ligand binding domain (LBD) of hPPARs.However, such assays are difficult because of the preparation of hPPARs LBD. In order to yield functional hPPARs LBD for screening ligands, hPPARs LBD was fused with maltose-binding protein(MBP) using the pMAL-p2x expression system through the gene engineering technique. The radioligand binding assay showed that MBP did not affect ligand binding with hPPARs LBD in the fusion proteins, which means that MBP-hPPARs LBD can be used instead of hPPARs LBD in ligand screening work. The results show that the new strategy using MBP as a fusion tag for preparing hPPARs LBD for screening ligands is a convenient and reliable method. It may be used to easily obtain the other nuclear receptors.

  16. Pediatric Amblyopia Risk Investigation Study (PARIS).

    PubMed

    Savage, Howard I; Lee, Hester H; Zaetta, Deneen; Olszowy, Ronald; Hamburger, Ellie; Weissman, Mark; Frick, Kevin

    2005-12-01

    To assess the learning curve, testability, and reliability of vision screening modalities administered by pediatric health extenders. Prospective masked clinical trial. Two hundred subjects aged 3 to 6 underwent timed screening for amblyopia by physician extenders, including LEA visual acuity (LEA), stereopsis (RDE), and noncycloplegic autorefraction (NCAR). Patients returned for a comprehensive diagnostic eye examination performed by an ophthalmologist or optometrist. Average screening time was 5.4 +/- 1.6 minutes (LEA), 1.9 +/- 0.9 minutes (RDE), and 1.7 +/- 1.0 minutes (NCAR). Test time for NCAR and RDE fell by 40% during the study period. Overall testability was 92% (LEA), 96% (RDE), and 94% (NCAR). Testability among 3-year-olds was 73% (LEA), 96% (RDE), and 89% (NCAR). Reliability of LEA was moderate (r = .59). Reliability of NCAR was high for astigmatism (Cyl) (r = .89), moderate for spherical equivalent (SE) (r = .66), and low for anisometropia (ANISO) (r = .38). Correlation of cycloplegic autorefraction (CAR) with gold standard cycloplegic retinoscopic refraction (CRR) was very high for SE (.85), CYL (.77), and moderate for ANISO (.48). With NCAR, physician extenders can quickly and reliably detect astigmatism and spherical refractive error in one-third the time it takes to obtain visual acuity. LEA has a lower initial cost, but is time consuming, moderately reliable, and more difficult for 3-year-olds. Shorter examination time and higher reliability may make NCAR a more efficient screening tool for refractive amblyopia in younger children. Future study is needed to determine the sensitivity and specificity of NCAR and other screening methods in detecting amblyopia and amblyopia risk factors.

  17. A Monte-Carlo method which is not based on Markov chain algorithm, used to study electrostatic screening of ion potential

    NASA Astrophysics Data System (ADS)

    Šantić, Branko; Gracin, Davor

    2017-12-01

    A new simple Monte Carlo method is introduced for the study of electrostatic screening by surrounding ions. The proposed method is not based on the generally used Markov chain method for sample generation. Each sample is pristine and there is no correlation with other samples. As the main novelty, the pairs of ions are gradually added to a sample provided that the energy of each ion is within the boundaries determined by the temperature and the size of ions. The proposed method provides reliable results, as demonstrated by the screening of ion in plasma and in water.

  18. Distributed Generation Interconnection Collaborative | NREL

    Science.gov Websites

    , reduce paperwork, and improve customer service. Analytical Methods for Interconnection Many utilities and jurisdictions are seeking the right screening and analytical methods and tools to meet their reliability

  19. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    PubMed Central

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  20. Improving Electronic Sensor Reliability by Robust Outlier Screening

    PubMed Central

    Moreno-Lizaranzu, Manuel J.; Cuesta, Federico

    2013-01-01

    Electronic sensors are widely used in different application areas, and in some of them, such as automotive or medical equipment, they must perform with an extremely low defect rate. Increasing reliability is paramount. Outlier detection algorithms are a key component in screening latent defects and decreasing the number of customer quality incidents (CQIs). This paper focuses on new spatial algorithms (Good Die in a Bad Cluster with Statistical Bins (GDBC SB) and Bad Bin in a Bad Cluster (BBBC)) and an advanced outlier screening method, called Robust Dynamic Part Averaging Testing (RDPAT), as well as two practical improvements, which significantly enhance existing algorithms. Those methods have been used in production in Freescale® Semiconductor probe factories around the world for several years. Moreover, a study was conducted with production data of 289,080 dice with 26 CQIs to determine and compare the efficiency and effectiveness of all these algorithms in identifying CQIs. PMID:24113682

  1. Improving electronic sensor reliability by robust outlier screening.

    PubMed

    Moreno-Lizaranzu, Manuel J; Cuesta, Federico

    2013-10-09

    Electronic sensors are widely used in different application areas, and in some of them, such as automotive or medical equipment, they must perform with an extremely low defect rate. Increasing reliability is paramount. Outlier detection algorithms are a key component in screening latent defects and decreasing the number of customer quality incidents (CQIs). This paper focuses on new spatial algorithms (Good Die in a Bad Cluster with Statistical Bins (GDBC SB) and Bad Bin in a Bad Cluster (BBBC)) and an advanced outlier screening method, called Robust Dynamic Part Averaging Testing (RDPAT), as well as two practical improvements, which significantly enhance existing algorithms. Those methods have been used in production in Freescale® Semiconductor probe factories around the world for several years. Moreover, a study was conducted with production data of 289,080 dice with 26 CQIs to determine and compare the efficiency and effectiveness of all these algorithms in identifying CQIs.

  2. Reliability and Validity of Observational Risk Screening in Evaluating Dynamic Knee Valgus

    PubMed Central

    Ekegren, Christina L.; Miller, William C.; Celebrini, Richard G.; Eng, Janice J.; MacIntyre, Donna L.

    2012-01-01

    Study Design Nonexperimental methodological study. Objectives To determine the interrater and intrarater reliability and validity of using observational risk screening guidelines to evaluate dynamic knee valgus. Background A deficiency in the neuromuscular control of the hip has been identified as a key risk factor for non-contact anterior cruciate ligament (ACL) injury in post pubescent females. This deficiency can manifest itself as a valgus knee alignment during tasks involving hip and knee flexion. There are currently no scientifically tested methods to screen for dynamic knee valgus in the clinic or on the field. Methods Three physiotherapists used observational risk screening guidelines to rate 40 adolescent female soccer players according to their risk of ACL injury. The rating was based on the amount of dynamic knee valgus observed on a drop jump landing. Ratings were evaluated for intrarater and interrater agreement using kappa coefficients. Sensitivity and specificity of ratings were evaluated by comparing observational ratings with measurements obtained using 3-dimensional (3D) motion analysis. Results Kappa coefficients for intrarater and interrater agreement ranged from 0.75 to 0.85, indicating that ratings were reasonably consistent over time and between physiotherapists. Sensitivity values were inadequate, ranging from 67–87%. This indicated that raters failed to detect up to a third of “truly high risk” individuals. Specificity values ranged from 60–72% which was considered adequate for the purposes of the screen. Conclusion Observational risk screening is a practical and cost-effective method of screening for ACL injury risk. Rater agreement and specificity were acceptable for this method but sensitivity was not. To detect a greater proportion of individuals at risk of ACL injury, coaches and clinicians should ensure that they include additional tests for other high risk characteristics in their screening protocols. PMID:19721212

  3. Screening for Elder Abuse among Turkish Older People: Validity of the Hwalek-Sengstock Elder Abuse Screening Test (H-S "East")

    ERIC Educational Resources Information Center

    Özmete, Emine; Megahead, Hamido A.

    2017-01-01

    Objective: This study aims to adapt "The Hwalek-Sengstock Elder Abuse Screening Test (H-S "East")" (Neale, Hwalek, Scott, Sengstock, & Stahl, 1991) to Turkish and to assess its validity and reliability while determining the factors that affect elder abuse. Method: The sample of the study is composed of 465 elderly women and…

  4. Comparing Interrater reliability between eye examination and eye self-examination 1

    PubMed Central

    de Lima, Maria Alzete; Pagliuca, Lorita Marlena Freitag; do Nascimento, Jennara Cândido; Caetano, Joselany Áfio

    2017-01-01

    Resume Objective: to compare Interrater reliability concerning two eye assessment methods. Method: quasi-experimental study conducted with 324 college students including eye self-examination and eye assessment performed by the researchers in a public university. Kappa coefficient was used to verify agreement. Results: reliability coefficients between Interraters ranged from 0.85 to 0.95, with statistical significance at 0.05. The exams to check for near acuity and peripheral vision presented a reasonable kappa >0.2. The remaining coefficients were higher, ranging from very to totally reliable. Conclusion: comparatively, the results of both methods were similar. The virtual manual on eye self-examination can be used to screen for eye conditions. PMID:29069269

  5. Evaluation of Quantitative Environmental Stress Screening (ESS) Methods. Volume 1

    DTIC Science & Technology

    1991-11-01

    required information on screening strength from the curvefitting parameters. The underlying theory and approach taken are discussed in Appendix A. To...in field 1020 arm St.,Vas AJ Ptr 0.4i Currpnt. c- ugt ~ing DU?/SYS 2.7264 Wll/IY.3 at Factory Stress- NaxiLMw outgoing W?is’ys 0.288 DrW/5?S at Field...182 125 K.W.Fertig and V.X. Murthy, Models for Reliability Growth During Burn-in: Theory and Applicat’ons,Proceedings 1978 Annual Reliability and

  6. Fatty acid ethyl esters (FAEEs) as markers for alcohol in meconium: method validation and implementation of a screening program for prenatal drug exposure.

    PubMed

    Hastedt, Martin; Krumbiegel, Franziska; Gapert, René; Tsokos, Michael; Hartwig, Sven

    2013-09-01

    Alcohol consumption during pregnancy is a widespread problem and can cause severe fetal damage. As the diagnosis of fetal alcohol syndrome is difficult, the implementation of a reliable marker for alcohol consumption during pregnancy into meconium drug screening programs would be invaluable. A previously published gas chromatography mass spectrometry method for the detection of fatty acid ethyl esters (FAEEs) as alcohol markers in meconium was optimized and newly validated for a sample size of 50 mg. This method was applied to 122 cases from a drug-using population. The meconium samples were also tested for common drugs of abuse. In 73 % of the cases, one or more drugs were found. Twenty percent of the samples tested positive for FAEEs at levels indicating significant alcohol exposure. Consequently, alcohol was found to be the third most frequently abused substance within the study group. This re-validated method provides an increase in testing sensitivity, is reliable and easily applicable as part of a drug screening program. It can be used as a non-invasive tool to detect high alcohol consumption in the last trimester of pregnancy. The introduction of FAEEs testing in meconium screening was found to be of particular use in a drug-using population.

  7. Performance Assessment of Internal Quality Control (IQC) Products in Blood Transfusion Compatibility Testing in China

    PubMed Central

    Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan

    2015-01-01

    Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582

  8. Measuring the Pain Area: An Intra- and Inter-Rater Reliability Study Using Image Analysis Software.

    PubMed

    Dos Reis, Felipe Jose Jandre; de Barros E Silva, Veronica; de Lucena, Raphaela Nunes; Mendes Cardoso, Bruno Alexandre; Nogueira, Leandro Calazans

    2016-01-01

    Pain drawings have frequently been used for clinical information and research. The aim of this study was to investigate intra- and inter-rater reliability of area measurements performed on pain drawings. Our secondary objective was to verify the reliability when using computers with different screen sizes, both with and without mouse hardware. Pain drawings were completed by patients with chronic neck pain or neck-shoulder-arm pain. Four independent examiners participated in the study. Examiners A and B used the same computer with a 16-inch screen and wired mouse hardware. Examiner C used a notebook with a 16-inch screen and no mouse hardware, and Examiner D used a computer with an 11.6-inch screen and a wireless mouse. Image measurements were obtained using GIMP and NIH ImageJ computer programs. The length of all the images was measured using GIMP software to a set scale in ImageJ. Thus, each marked area was encircled and the total surface area (cm(2) ) was calculated for each pain drawing measurement. A total of 117 areas were identified and 52 pain drawings were analyzed. The intrarater reliability between all examiners was high (ICC = 0.989). The inter-rater reliability was also high. No significant differences were observed when using different screen sizes or when using or not using the mouse hardware. This suggests that the precision of these measurements is acceptable for the use of this method as a measurement tool in clinical practice and research. © 2014 World Institute of Pain.

  9. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department

    PubMed Central

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C.; Lee, Jacques S.

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years (M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r-values) between 0.5 and 0.8 across adjacent sessions. Conclusion: The game-based assessment for cognitive screening has relatively strong test-retest reliability and little evidence of practice effects among elderly emergency patients, and may be a useful supplement to existing cognitive assessment methods. PMID:27872590

  10. [Primary care screening of problems in the elderly and a proposal for a screening protocol with a multidimensional approach].

    PubMed

    Lino, Valéria Teresa Saraiva; Portela, Margareth Crisóstomo; Camacho, Luiz Antonio Bastos; Rodrigues, Nadia Cristina Pinheiro; Andrade, Monica Kramer de Noronha; O'Dwyer, Gisele

    2016-07-21

    The objectives were to examine psychometric properties of a screening test for the elderly and to propose a protocol for use in primary care. The method consisted of four stages: (1) inter-evaluator reliability for performance tests and self-assessment questions for eight functions; (2) sensitivity and specificity of questions on depression and social support; (3) meeting of experts to select instrumental activities of daily living (IADL); and (4) elaboration of the protocol. Screening lasted 16 minutes. Inter-evaluator reliability was excellent for performance tests but poor for questions. Depression and social support showed satisfactory sensitivity and specificity (0.74/0.77 and 0.77/0.96). Four IADL were selected by more than 55% of the experts. Following the results, a screening protocol was elaborated that prioritized the use of performance tests, maintaining questions on mood, social support, and IADL. The study suggests better reproducibility of performance tests when compared to questions. For mood and social support, the questions may provide a first screening stage. The proposed protocol allows rapid screening of problems.

  11. Evaluation of Microelectrode Array Data using Bayesian Modeling as an Approach to Screening and Prioritization for Neurotoxicity Testing*

    EPA Science Inventory

    The need to assess large numbers of chemicals for their potential toxicities has resulted in increased emphasis on medium- and high-throughput in vitro screening approaches. For such approaches to be useful, efficient and reliable data analysis and hit detection methods are also ...

  12. Identifying Children at Risk for Language Impairment or Dyslexia with Group-Administered Measures

    ERIC Educational Resources Information Center

    Adlof, Suzanne M.; Scoggins, Joanna; Brazendale, Allison; Babb, Spencer; Petscher, Yaacov

    2017-01-01

    Purpose: The study aims to determine whether brief, group-administered screening measures can reliably identify second-grade children at risk for language impairment (LI) or dyslexia and to examine the degree to which parents of affected children were aware of their children's difficulties. Method: Participants (N = 381) completed screening tasks…

  13. A Primer for DoD Reliability, Maintainability, Safety, and Logistics Standards, 1992

    DTIC Science & Technology

    1991-10-01

    equipment, identified in the order of application (i.e., assembly, unit and system screens). Screening Strength ( SS ) - The probability that a screen...As’- ss equipment suitability for its intended operational environment. c. Verify contractual compliance. Each test method is divided into two...SIMULA-ITno Q.A. j FABRICATION, VALIDATION AD CONCERNS j PACKAGE AND SAnSFACTORY MBI Y QUALIMCATION RE UIREMENTS NO QRA TESTS YES QMLFOR TECHNOLOGY

  14. Cross-Cultural Adaptation, Validity, and Reliability of the Persian Version of the Orebro Musculoskeletal Pain Screening Questionnaire.

    PubMed

    Shafeei, Asrin; Mokhtarinia, Hamid Reza; Maleki-Ghahfarokhi, Azam; Piri, Leila

    2017-08-01

    Observational study. To cross-culturally translate the Orebro Musculoskeletal Pain Screening Questionnaire (OMPQ) into Persian and then evaluate its psychometric properties (reliability, validity, ceiling, and flooring effects). To the authors' knowledge, prior to this study there has been no validated instrument to screen the risk of chronicity in Persian-speaking patients with low back pain (LBP) in Iran. The OMPQ was specifically developed as a self-administered screening tool for assessing the risk of LBP chronicity. The forward-backward translation method was used for the translation and cross-cultural adaptation of the original questionnaire. In total, 202 patients with subacute LBP completed the OMPQ and the pain disability questionnaire (PDQ), which was used to assess convergent validity. 62 patients completed the OMPQ a week later as a retest. Slight changes were made to the OMPQ during the translation/cultural adaptation process; face validity of the Persian version was obtained. The Persian OMPQ showed excellent test-retest reliability (intraclass correlation coefficient=0.89). Its internal consistency was 0.71, and its convergent validity was confirmed by good correlation coefficient between the OMPQ and PDQ total scores ( r =0.72, p <0.05). No ceiling or floor effects were observed. The Persian version of the OMPQ is acceptable for the target society in terms of face validity, construct validity, reliability, and consistency. It is therefore considered a useful instrument for screening Iranian patients with LBP.

  15. Cross-Cultural Adaptation of a Pre-School Screening Instrument: Comparison of Korean and US Populations

    ERIC Educational Resources Information Center

    Heo, K. H.; Squires, J.; Yovanoff, P.

    2008-01-01

    Background: Accurate and efficient developmental screening measures are critical for early identification of developmental problems; however, few reliable and valid tests are available in Korea as well as other countries outside the USA. The Ages and Stages Questionnaires (ASQ) was chosen for study with young children in Korea. Methods: The ASQ…

  16. Use of short messaging services to assess depressive symptoms among refugees in South Africa: Implications for social services providing mental health care in resource-poor settings

    PubMed Central

    Tomita, Andrew; Kandolo, Ka Muzombo; Susser, Ezra; Burns, Jonathan K

    2016-01-01

    Few studies in developing nations have assessed the use of short messaging services (SMS) to identify psychological challenges in refugee populations. This study aimed to assess the feasibility of SMS-based methods to screen for depression risk among refugees in South Africa attending mental health services, and to compare its reliability and acceptability with face-to-face consultation. Of the 153 refugees enrolled at baseline, 135 were available for follow-up assessments in our cohort study. Depression symptomatology was assessed using the 16-item Quick Inventory of Depressive Symptomatology (QIDS) instrument. Nearly everyone possessed a mobile phone and utilized SMS. Furthermore, low incomplete item response in QIDS and high perceived ease of interacting via SMS with service providers supported the feasibility of this method. There was a fair level of reliability between face-to-face and SMS-based screening methods, but no significant difference in preference rating between the two methods. Despite potential implementation barriers (network delay/phone theft), depression screening using SMS may be viable for refugee mental health services in low-resource settings. PMID:26407989

  17. The measurement of patient attitudes regarding prenatal and preconception genetic carrier screening and translational behavioral medicine: an integrative review.

    PubMed

    Shiroff, Jennifer J; Gregoski, Mathew J

    2017-06-01

    Measurement of recessive carrier screening attitudes related to conception and pregnancy is necessary to determine current acceptance, and whether behavioral intervention strategies are needed in clinical practice. To evaluate quantitative survey instruments to measure patient attitudes regarding genetic carrier testing prior to conception and pregnancy databases examining patient attitudes regarding genetic screening prior to conception and pregnancy from 2003-2013 were searched yielding 344 articles; eight studies with eight instruments met criteria for inclusion. Data abstraction on theoretical framework, subjects, instrument description, scoring, method of measurement, reliability, validity, feasibility, level of evidence, and outcomes was completed. Reliability information was provided in five studies with an internal consistency of Cronbach's α >0.70. Information pertaining to validity was presented in three studies and included construct validity via factor analysis. Despite limited psychometric information, these questionnaires are self-administered and can be briefly completed, making them a feasible method of evaluation.

  18. Development of an analytical method coupling cell membrane chromatography with gas chromatography-mass spectrometry via microextraction by packed sorbent and its application in the screening of volatile active compounds in natural products.

    PubMed

    Li, Miao; Wang, Sicen; He, Langchong

    2015-01-01

    Natural products (NPs) are important sources of lead compounds in modern drug discovery. To facilitate the screening of volatile active compounds in NPs, we have developed a new biochromatography method that uses rat vascular smooth muscle cells (VSMC), which are rich in L-type calcium channels (LCC), to prepare the stationary phase. This integrated method, which couples cell membrane chromatography (CMC) with gas chromatography-mass spectrometry (GC-MS) via microextraction by packed sorbent (MEPS) technology, has been termed VSMC/CMC-MEPS-GC-MS. Methodological validation confirmed its specificity, reliability and convenience. Screening results for Radix Angelicae Dahuricae and Fructus Cnidii obtained using VSMC/CMC-MEPS-GC-MS were consistent with those obtained using VSMC/CMC-offline-GC-MS. MEPS connection plays as simplified solid-phase extraction and replaces the uncontrollable evaporation operation in reported offline connections, so our new method is supposed to be more efficient and reliable than the offline ones, especially for compounds that are volatile, thermally unstable or difficult to purify. In application, senkyunolide A and ligustilide were preliminary identified as the volatile active components in Rhizoma Chuanxiong. We have thus confirmed the suitability of VSMC/CMC-MEPS-GC-MS for volatile active compounds screening in NP. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Rapid, sensitive and reproducible method for point-of-collection screening of liquid milk for adulterants using a portable Raman spectrometer with novel optimized sample well

    NASA Astrophysics Data System (ADS)

    Nieuwoudt, Michel K.; Holroyd, Steve E.; McGoverin, Cushla M.; Simpson, M. Cather; Williams, David E.

    2017-02-01

    Point-of-care diagnostics are of interest in the medical, security and food industry, the latter particularly for screening food adulterated for economic gain. Milk adulteration continues to be a major problem worldwide and different methods to detect fraudulent additives have been investigated for over a century. Laboratory based methods are limited in their application to point-of-collection diagnosis and also require expensive instrumentation, chemicals and skilled technicians. This has encouraged exploration of spectroscopic methods as more rapid and inexpensive alternatives. Raman spectroscopy has excellent potential for screening of milk because of the rich complexity inherent in its signals. The rapid advances in photonic technologies and fabrication methods are enabling increasingly sensitive portable mini-Raman systems to be placed on the market that are both affordable and feasible for both point-of-care and point-of-collection applications. We have developed a powerful spectroscopic method for rapidly screening liquid milk for sucrose and four nitrogen-rich adulterants (dicyandiamide (DCD), ammonium sulphate, melamine, urea), using a combined system: a small, portable Raman spectrometer with focusing fibre optic probe and optimized reflective focusing wells, simply fabricated in aluminium. The reliable sample presentation of this system enabled high reproducibility of 8% RSD (residual standard deviation) within four minutes. Limit of detection intervals for PLS calibrations ranged between 140 - 520 ppm for the four N-rich compounds and between 0.7 - 3.6 % for sucrose. The portability of the system and reliability and reproducibility of this technique opens opportunities for general, reagentless adulteration screening of biological fluids as well as milk, at point-of-collection.

  20. Reliability and Validity of a Two-Question Alcohol Screen in the Pediatric Emergency Department

    PubMed Central

    Spirito, Anthony; Bromberg, Julie R.; Casper, T. Charles; Chun, Thomas H.; Mello, Michael J.; Dean, J. Michael

    2016-01-01

    BACKGROUND AND OBJECTIVE: A multisite study was conducted to determine the psychometric properties of the National Institute of Alcohol Abuse and Alcoholism (NIAAA) 2-question alcohol screen within pediatric emergency departments (PEDs). METHODS: Participants (N = 4838) included 12- to 17-year-old subjects treated in 1 of the 16 participating PEDs across the United States. A criterion assessment battery (including the NIAAA 2-question alcohol screen and other measures of alcohol, drug use, and risk behaviors) was self-administered on a tablet computer. A subsample (n = 186) was re-administered the NIAAA 2-question screen 1 week later to assess test-retest reliability. RESULTS: Moderate to good test-retest reliability was demonstrated. A classification of moderate risk or higher on the screen had the best combined sensitivity and specificity for determining a diagnosis of alcohol use disorder (AUD) for all students. Any past year drinking among middle school students increased the odds of a diagnosis of an AUD according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition criteria, whereas the optimal cutoff for high school ages was ≥3 drinking days in the past year. The optimal cutoff for drinking days determining a positive Alcohol Use Disorders Identification Test score among middle school subjects was ≥1 drinking day, whereas the optimal cutoff for high school subjects was ≥2 drinking days. CONCLUSIONS: The NIAAA 2-question screen is a brief, valid approach for alcohol screening in PEDs. A positive screen suggests that referral for further evaluation is indicated to determine if an adolescent has an AUD. PMID:27940674

  1. [Psychometric properties and diagnostic value of 'lexical screening for aphasias'].

    PubMed

    Pena-Chavez, R; Martinez-Jimenez, L; Lopez-Espinoza, M

    2014-09-16

    INTRODUCTION. Language assessment in persons with brain injury makes it possible to know whether they require language rehabilitation or not. Given the importance of a precise evaluation, assessment instruments must be valid and reliable, so as to avoid mistaken and subjective diagnoses. AIM. To validate 'lexical screening for aphasias' in a sample of 58 Chilean individuals. SUBJECTS AND METHODS. A screening-type language test, lasting 20 minutes and based on the lexical processing model devised by Patterson and Shewell (1987), was constructed. The sample was made up of two groups containing 29 aphasic subjects and 29 control subjects from different health centres in the regions of Biobio and Maule, Chile. Their ages ranged between 24 and 79 years and had between 0 and 17 years' schooling. Tests were carried out to determine discriminating validity, concurrent validity with the aphasia disorder assessment battery, reliability, sensitivity and specificity. RESULTS. The statistical analysis showed a high discriminating validity (p < 0.001), an acceptable mean concurrent validity with aphasia disorder assessment battery (rs = 0.65), high mean reliability (alpha = 0.87), moderate mean sensitivity (69%) and high mean specificity (86%). CONCLUSION. 'Lexical screening for aphasias' is valid and reliable for assessing language in persons with aphasias; it is sensitive for detecting aphasic subjects and is specific for precluding language disorders in persons with normal language abilities.

  2. Developing and validating a perinatal depression screening tool in Kenya blending Western criteria with local idioms: A mixed methods study.

    PubMed

    Green, Eric P; Tuli, Hawa; Kwobah, Edith; Menya, D; Chesire, Irene; Schmidt, Christina

    2018-03-01

    Routine screening for perinatal depression is not common in most primary health care settings. The U.S. Preventive Services Task Force only recently updated their recommendation on depression screening to specifically recommend screening during the pre- and postpartum periods. While practitioners in high-income countries can respond to this new recommendation by implementing one of several existing depression screening tools developed in Western contexts, such as the Edinburgh Postnatal Depression Scale (EPDS) or the Patient Health Questionnaire-9 (PHQ-9), these tools lack strong evidence of cross-cultural equivalence, validity for case finding, and precision in measuring response to treatment in developing countries. Thus, there is a critical need to develop and validate new screening tools for perinatal depression that can be used by lay health workers, primary health care personnel, and patients. Working in rural Kenya, we used free listing, card sorting, and item analysis methods to develop a locally-relevant screening tool that blended Western psychiatric concepts with local idioms of distress. We conducted a validation study with a random sample of 193 pregnant women and new mothers to test the diagnostic accuracy of this scale along with the EPDS and PHQ-9. The sensitivity/specificity of the EPDS and PHQ-9 was estimated to be 0.70/0.72 and 0.70/0.73, respectively. This compared to sensitivity/specificity of 0.90/0.90 for a new 9-item locally-developed tool called the Perinatal Depression Screening (PDEPS). Across these three tools, internal consistency reliability ranged from 0.77 to 0.81 and test-retest reliability ranged from 0.57 to 0.67. The prevalence of depression ranges from 5.2% to 6.2% depending on the clinical reference standard. The EPDS and PHQ-9 are valid and reliable screening tools for perinatal depression in rural Western Kenya, the PDEPS may be a more useful alternative. At less than 10%, the prevalence of depression in this region appears to be lower than other published estimates for African and other low-income countries. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Establishing high resolution melting analysis: method validation and evaluation for c-RET proto-oncogene mutation screening.

    PubMed

    Benej, Martin; Bendlova, Bela; Vaclavikova, Eliska; Poturnajova, Martina

    2011-10-06

    Reliable and effective primary screening of mutation carriers is the key condition for common diagnostic use. The objective of this study is to validate the method high resolution melting (HRM) analysis for routine primary mutation screening and accomplish its optimization, evaluation and validation. Due to their heterozygous nature, germline point mutations of c-RET proto-oncogene, associated to multiple endocrine neoplasia type 2 (MEN2), are suitable for HRM analysis. Early identification of mutation carriers has a major impact on patients' survival due to early onset of medullary thyroid carcinoma (MTC) and resistance to conventional therapy. The authors performed a series of validation assays according to International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines for validation of analytical procedures, along with appropriate design and optimization experiments. After validated evaluation of HRM, the method was utilized for primary screening of 28 pathogenic c-RET mutations distributed among nine exons of c-RET gene. Validation experiments confirm the repeatability, robustness, accuracy and reproducibility of HRM. All c-RET gene pathogenic variants were detected with no occurrence of false-positive/false-negative results. The data provide basic information about design, establishment and validation of HRM for primary screening of genetic variants in order to distinguish heterozygous point mutation carriers among the wild-type sequence carriers. HRM analysis is a powerful and reliable tool for rapid and cost-effective primary screening, e.g., of c-RET gene germline and/or sporadic mutations and can be used as a first line potential diagnostic tool.

  4. Assessment of wheelchair driving performance in a virtual reality-based simulator

    PubMed Central

    Mahajan, Harshal P.; Dicianno, Brad E.; Cooper, Rory A.; Ding, Dan

    2013-01-01

    Objective To develop a virtual reality (VR)-based simulator that can assist clinicians in performing standardized wheelchair driving assessments. Design A completely within-subjects repeated measures design. Methods Participants drove their wheelchairs along a virtual driving circuit modeled after the Power Mobility Road Test (PMRT) and in a hallway with decreasing width. The virtual simulator was displayed on computer screen and VR screens and participants interacted with it using a set of instrumented rollers and a wheelchair joystick. Driving performances of participants were estimated and compared using quantitative metrics from the simulator. Qualitative ratings from two experienced clinicians were used to estimate intra- and inter-rater reliability. Results Ten regular wheelchair users (seven men, three women; mean age ± SD, 39.5 ± 15.39 years) participated. The virtual PMRT scores from the two clinicians show high inter-rater reliability (78–90%) and high intra-rater reliability (71–90%) for all test conditions. More research is required to explore user preferences and effectiveness of the two control methods (rollers and mathematical model) and the display screens. Conclusions The virtual driving simulator seems to be a promising tool for wheelchair driving assessment that clinicians can use to supplement their real-world evaluations. PMID:23820148

  5. Quadruplex MAPH: improvement of throughput in high-resolution copy number screening.

    PubMed

    Tyson, Jess; Majerus, Tamsin Mo; Walker, Susan; Armour, John Al

    2009-09-28

    Copy number variation (CNV) in the human genome is recognised as a widespread and important source of human genetic variation. Now the challenge is to screen for these CNVs at high resolution in a reliable, accurate and cost-effective way. Multiplex Amplifiable Probe Hybridisation (MAPH) is a sensitive, high-resolution technology appropriate for screening for CNVs in a defined region, for a targeted population. We have developed MAPH to a highly multiplexed format ("QuadMAPH") that allows the user a four-fold increase in the number of loci tested simultaneously. We have used this method to analyse a genomic region of 210 kb, including the MSH2 gene and 120 kb of flanking DNA. We show that the QuadMAPH probes report copy number with equivalent accuracy to simplex MAPH, reliably demonstrating diploid copy number in control samples and accurately detecting deletions in Hereditary Non-Polyposis Colorectal Cancer (HNPCC) samples. QuadMAPH is an accurate, high-resolution method that allows targeted screening of large numbers of subjects without the expense of genome-wide approaches. Whilst we have applied this technique to a region of the human genome, it is equally applicable to the genomes of other organisms.

  6. Quadruplex MAPH: improvement of throughput in high-resolution copy number screening

    PubMed Central

    Tyson, Jess; Majerus, Tamsin MO; Walker, Susan; Armour, John AL

    2009-01-01

    Background Copy number variation (CNV) in the human genome is recognised as a widespread and important source of human genetic variation. Now the challenge is to screen for these CNVs at high resolution in a reliable, accurate and cost-effective way. Results Multiplex Amplifiable Probe Hybridisation (MAPH) is a sensitive, high-resolution technology appropriate for screening for CNVs in a defined region, for a targeted population. We have developed MAPH to a highly multiplexed format ("QuadMAPH") that allows the user a four-fold increase in the number of loci tested simultaneously. We have used this method to analyse a genomic region of 210 kb, including the MSH2 gene and 120 kb of flanking DNA. We show that the QuadMAPH probes report copy number with equivalent accuracy to simplex MAPH, reliably demonstrating diploid copy number in control samples and accurately detecting deletions in Hereditary Non-Polyposis Colorectal Cancer (HNPCC) samples. Conclusion QuadMAPH is an accurate, high-resolution method that allows targeted screening of large numbers of subjects without the expense of genome-wide approaches. Whilst we have applied this technique to a region of the human genome, it is equally applicable to the genomes of other organisms. PMID:19785739

  7. Statistical studies of animal response data from USF toxicity screening test method

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Machado, A. M.

    1978-01-01

    Statistical examination of animal response data obtained using Procedure B of the USF toxicity screening test method indicates that the data deviate only slightly from a normal or Gaussian distribution. This slight departure from normality is not expected to invalidate conclusions based on theoretical statistics. Comparison of times to staggering, convulsions, collapse, and death as endpoints shows that time to death appears to be the most reliable endpoint because it offers the lowest probability of missed observations and premature judgements.

  8. The GMOseek matrix: a decision support tool for optimizing the detection of genetically modified plants.

    PubMed

    Block, Annette; Debode, Frédéric; Grohmann, Lutz; Hulin, Julie; Taverniers, Isabel; Kluga, Linda; Barbau-Piednoir, Elodie; Broeders, Sylvia; Huber, Ingrid; Van den Bulcke, Marc; Heinze, Petra; Berben, Gilbert; Busch, Ulrich; Roosens, Nancy; Janssen, Eric; Žel, Jana; Gruden, Kristina; Morisset, Dany

    2013-08-22

    Since their first commercialization, the diversity of taxa and the genetic composition of transgene sequences in genetically modified plants (GMOs) are constantly increasing. To date, the detection of GMOs and derived products is commonly performed by PCR-based methods targeting specific DNA sequences introduced into the host genome. Information available regarding the GMOs' molecular characterization is dispersed and not appropriately organized. For this reason, GMO testing is very challenging and requires more complex screening strategies and decision making schemes, demanding in return the use of efficient bioinformatics tools relying on reliable information. The GMOseek matrix was built as a comprehensive, online open-access tabulated database which provides a reliable, comprehensive and user-friendly overview of 328 GMO events and 247 different genetic elements (status: 18/07/2013). The GMOseek matrix is aiming to facilitate GMO detection from plant origin at different phases of the analysis. It assists in selecting the targets for a screening analysis, interpreting the screening results, checking the occurrence of a screening element in a group of selected GMOs, identifying gaps in the available pool of GMO detection methods, and designing a decision tree. The GMOseek matrix is an independent database with effective functionalities in a format facilitating transferability to other platforms. Data were collected from all available sources and experimentally tested where detection methods and certified reference materials (CRMs) were available. The GMOseek matrix is currently a unique and very valuable tool with reliable information on GMOs from plant origin and their present genetic elements that enables further development of appropriate strategies for GMO detection. It is flexible enough to be further updated with new information and integrated in different applications and platforms.

  9. The GMOseek matrix: a decision support tool for optimizing the detection of genetically modified plants

    PubMed Central

    2013-01-01

    Background Since their first commercialization, the diversity of taxa and the genetic composition of transgene sequences in genetically modified plants (GMOs) are constantly increasing. To date, the detection of GMOs and derived products is commonly performed by PCR-based methods targeting specific DNA sequences introduced into the host genome. Information available regarding the GMOs’ molecular characterization is dispersed and not appropriately organized. For this reason, GMO testing is very challenging and requires more complex screening strategies and decision making schemes, demanding in return the use of efficient bioinformatics tools relying on reliable information. Description The GMOseek matrix was built as a comprehensive, online open-access tabulated database which provides a reliable, comprehensive and user-friendly overview of 328 GMO events and 247 different genetic elements (status: 18/07/2013). The GMOseek matrix is aiming to facilitate GMO detection from plant origin at different phases of the analysis. It assists in selecting the targets for a screening analysis, interpreting the screening results, checking the occurrence of a screening element in a group of selected GMOs, identifying gaps in the available pool of GMO detection methods, and designing a decision tree. The GMOseek matrix is an independent database with effective functionalities in a format facilitating transferability to other platforms. Data were collected from all available sources and experimentally tested where detection methods and certified reference materials (CRMs) were available. Conclusions The GMOseek matrix is currently a unique and very valuable tool with reliable information on GMOs from plant origin and their present genetic elements that enables further development of appropriate strategies for GMO detection. It is flexible enough to be further updated with new information and integrated in different applications and platforms. PMID:23965170

  10. Fragment length analysis screening for detection of CEBPA mutations in intermediate-risk karyotype acute myeloid leukemia.

    PubMed

    Fuster, Oscar; Barragán, Eva; Bolufer, Pascual; Such, Esperanza; Valencia, Ana; Ibáñez, Mariam; Dolz, Sandra; de Juan, Inmaculada; Jiménez, Antonio; Gómez, Maria Teresa; Buño, Ismael; Martínez, Joaquín; Cervera, José; Montesinos, Pau; Moscardó, Federico; Sanz, Miguel Ángel

    2012-01-01

    During last years, molecular markers have been increased as prognostic factors routinely screened in acute myeloid leukemia (AML). Recently, an increasing interest has been reported in introducing to clinical practice screening for mutations in the CCAAT/enhancer-binding protein α (CEBPA) gene in AML, as it seems to be a good prognostic factor. However, there is no reliable established method for assessing CEBPA mutations during the diagnostic work-up of AMLs. We describe here a straightforward and reliable fragment analysis method based in PCR capillary electrophoresis (PCR-CE) for screening of CEBPA mutations; moreover, we present the results obtained in 151 intermediate-risk karyotype AML patients (aged 16-80 years). The method gave a specificity of 100% and sensitivity of 93% with a lower detection limit of 1-5% for CEBPA mutations. The series found 19 mutations and four polymorphisms in 12 patients, seven of whom (58%) presented two mutations. The overall frequency of CEBPA mutations in AML was 8% (n = 12). CEBPA mutations showed no coincidence with FLT3-ITD or NPM1 mutations. CEBPA mutation predicted better disease-free survival in the group of patients without FLT3-ITD, NPM, or both genes mutated (HR 3.6, IC 95%; 1.0-13.2, p = 0.05) and better overall survival in patients younger than 65 of this group without molecular markers (HR 4.0, IC 95%; 1.0-17.4, p = 0.05). In conclusion, the fragment analysis method based in PCR-CE is a rapid, specific, and sensitive method for CEBPA mutation screening and our results confirm that CEBPA mutations can identify a subgroup of patients with favorable prognosis in AML with intermediate-risk karyotype.

  11. Comparison of array comparative genomic hybridization and quantitative real-time PCR-based aneuploidy screening of blastocyst biopsies.

    PubMed

    Capalbo, Antonio; Treff, Nathan R; Cimadomo, Danilo; Tao, Xin; Upham, Kathleen; Ubaldi, Filippo Maria; Rienzi, Laura; Scott, Richard T

    2015-07-01

    Comprehensive chromosome screening (CCS) methods are being extensively used to select chromosomally normal embryos in human assisted reproduction. Some concerns related to the stage of analysis and which aneuploidy screening method to use still remain. In this study, the reliability of blastocyst-stage aneuploidy screening and the diagnostic performance of the two mostly used CCS methods (quantitative real-time PCR (qPCR) and array comparative genome hybridization (aCGH)) has been assessed. aCGH aneuploid blastocysts were rebiopsied, blinded, and evaluated by qPCR. Discordant cases were subsequently rebiopsied, blinded, and evaluated by single-nucleotide polymorphism (SNP) array-based CCS. Although 81.7% of embryos showed the same diagnosis when comparing aCGH and qPCR-based CCS, 18.3% (22/120) of embryos gave a discordant result for at least one chromosome. SNP array reanalysis showed that a discordance was reported in ten blastocysts for aCGH, mostly due to false positives, and in four cases for qPCR. The discordant aneuploidy call rate per chromosome was significantly higher for aCGH (5.7%) compared with qPCR (0.6%; P<0.01). To corroborate these findings, 39 embryos were simultaneously biopsied for aCGH and qPCR during blastocyst-stage aneuploidy screening cycles. 35 matched including all 21 euploid embryos. Blinded SNP analysis on rebiopsies of the four embryos matched qPCR. These findings demonstrate the high reliability of diagnosis performed at the blastocyst stage with the use of different CCS methods. However, the application of aCGH can be expected to result in a higher aneuploidy rate than other contemporary methods of CCS.

  12. Between-Day Reliability of Pre-Participation Screening Components in Pre-Professional Ballet and Contemporary Dancers.

    PubMed

    Kenny, Sarah J; Palacios-Derflingher, Luz; Owoeye, Oluwatoyosi B A; Whittaker, Jackie L; Emery, Carolyn A

    2018-03-15

    Critical appraisal of research investigating risk factors for musculoskeletal injury in dancers suggests high quality reliability studies are lacking. The purpose of this study was to determine between-day reliability of pre-participation screening (PPS) components in pre-professional ballet and contemporary dancers. Thirty-eight dancers (35 female, 3 male; median age; 18 years; range: 11 to 30 years) participated. Screening components (Athletic Coping Skills Inventory-28, body mass index, percent total body fat, total bone mineral density, Foot Posture Index-6, hip and ankle range of motion, three lumbopelvic control tasks, unipedal dynamic balance, and the Y-Balance Test) were conducted one week apart. Intra-class correlation coefficients (ICCs: 95% confidence intervals), standard error of measurement, minimal detectable change (MDC), Bland-Altman methods of agreement [95% limits of agreement (LOA)], Cohen's kappa coefficients, standard error, and percent agreements were calculated. Depending on the screening component, ICC estimates ranged from 0.51 to 0.98, kappa coefficients varied between -0.09 and 0.47, and percent agreement spanned 71% to 95%. Wide 95% LOA were demonstrated by Foot Posture Index-6 (right: -6.06, 7.31), passive hip external rotation (right: -9.89, 16.54), and passive supine turnout (left: -15.36, 17.58). The PPS components examined demonstrated moderate to excellent relative reliability with mean between-day differences less than MDC, or sufficient percent agreement, across all assessments. However, due to wide 95% limits of agreement, the Foot Posture Index-6 and passive hip range of motion are not recommended for screening injury risk in pre-professional dancers.

  13. Adaptation and Assessment of Reliability and Validity of the Greek Version of the Ohkuma Questionnaire for Dysphagia Screening.

    PubMed

    Papadopoulou, Soultana L; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam

    2017-01-01

    Introduction  The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective  The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods  Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results  According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p  = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements ( p  = 0.02 and p  = 0.016). Conclusion  The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients.

  14. Measuring reliable change in cognition using the Edinburgh Cognitive and Behavioural ALS Screen (ECAS).

    PubMed

    Crockford, Christopher; Newton, Judith; Lonergan, Katie; Madden, Caoifa; Mays, Iain; O'Sullivan, Meabhdh; Costello, Emmet; Pinto-Grau, Marta; Vajda, Alice; Heverin, Mark; Pender, Niall; Al-Chalabi, Ammar; Hardiman, Orla; Abrahams, Sharon

    2018-02-01

    Cognitive impairment affects approximately 50% of people with amyotrophic lateral sclerosis (ALS). Research has indicated that impairment may worsen with disease progression. The Edinburgh Cognitive and Behavioural ALS Screen (ECAS) was designed to measure neuropsychological functioning in ALS, with its alternate forms (ECAS-A, B, and C) allowing for serial assessment over time. The aim of the present study was to establish reliable change scores for the alternate forms of the ECAS, and to explore practice effects and test-retest reliability of the ECAS's alternate forms. Eighty healthy participants were recruited, with 57 completing two and 51 completing three assessments. Participants were administered alternate versions of the ECAS serially (A-B-C) at four-month intervals. Intra-class correlation analysis was employed to explore test-retest reliability, while analysis of variance was used to examine the presence of practice effects. Reliable change indices (RCI) and regression-based methods were utilized to establish change scores for the ECAS alternate forms. Test-retest reliability was excellent for ALS Specific, ALS Non-Specific, and ECAS Total scores of the combined ECAS A, B, and C (all > .90). No significant practice effects were observed over the three testing sessions. RCI and regression-based methods produced similar change scores. The alternate forms of the ECAS possess excellent test-retest reliability in a healthy control sample, with no significant practice effects. The use of conservative RCI scores is recommended. Therefore, a change of ≥8, ≥4, and ≥9 for ALS Specific, ALS Non-Specific, and ECAS Total score is required for reliable change.

  15. Is School-Based Height and Weight Screening of Elementary Students Private and Reliable?

    ERIC Educational Resources Information Center

    Stoddard, Sarah A.; Kubik, Martha Y.; Skay, Carol

    2008-01-01

    The Institute of Medicine recommends school-based body mass index (BMI) screening as an obesity prevention strategy. While school nurses have provided height/weight screening for years, little has been published describing measurement reliability or process. This study evaluated the reliability of height/weight measures collected by school nurses…

  16. Screening of the key volatile organic compounds of Tuber melanosporum fermentation by aroma sensory evaluation combination with principle component analysis

    PubMed Central

    Liu, Rui-Sang; Jin, Guang-Huai; Xiao, Deng-Rong; Li, Hong-Mei; Bai, Feng-Wu; Tang, Ya-Jie

    2015-01-01

    Aroma results from the interplay of volatile organic compounds (VOCs) and the attributes of microbial-producing aromas are significantly affected by fermentation conditions. Among the VOCs, only a few of them contribute to aroma. Thus, screening and identification of the key VOCs is critical for microbial-producing aroma. The traditional method is based on gas chromatography-olfactometry (GC-O), which is time-consuming and laborious. Considering the Tuber melanosporum fermentation system as an example, a new method to screen and identify the key VOCs by combining the aroma evaluation method with principle component analysis (PCA) was developed in this work. First, an aroma sensory evaluation method was developed to screen 34 potential favorite aroma samples from 504 fermentation samples. Second, PCA was employed to screen nine common key VOCs from these 34 samples. Third, seven key VOCs were identified by the traditional method. Finally, all of the seven key VOCs identified by the traditional method were also identified, along with four others, by the new strategy. These results indicate the reliability of the new method and demonstrate it to be a viable alternative to the traditional method. PMID:26655663

  17. Machine learning plus optical flow: a simple and sensitive method to detect cardioactive drugs

    NASA Astrophysics Data System (ADS)

    Lee, Eugene K.; Kurokawa, Yosuke K.; Tu, Robin; George, Steven C.; Khine, Michelle

    2015-07-01

    Current preclinical screening methods do not adequately detect cardiotoxicity. Using human induced pluripotent stem cell-derived cardiomyocytes (iPS-CMs), more physiologically relevant preclinical or patient-specific screening to detect potential cardiotoxic effects of drug candidates may be possible. However, one of the persistent challenges for developing a high-throughput drug screening platform using iPS-CMs is the need to develop a simple and reliable method to measure key electrophysiological and contractile parameters. To address this need, we have developed a platform that combines machine learning paired with brightfield optical flow as a simple and robust tool that can automate the detection of cardiomyocyte drug effects. Using three cardioactive drugs of different mechanisms, including those with primarily electrophysiological effects, we demonstrate the general applicability of this screening method to detect subtle changes in cardiomyocyte contraction. Requiring only brightfield images of cardiomyocyte contractions, we detect changes in cardiomyocyte contraction comparable to - and even superior to - fluorescence readouts. This automated method serves as a widely applicable screening tool to characterize the effects of drugs on cardiomyocyte function.

  18. Comparison of in vivo and in vitro survival and fecundity rates of the poultry red mite, Dermanyssus gallinae.

    PubMed

    Arkle, S; George, D R; Guy, J H; Sparagano, O A E

    2010-04-01

    To assist in the testing of possible antigens in developing a vaccine against the poultry red mite (Dermanyssus gallinae De Geer), a rapid and reliable in vitro screening method is critical. This short paper describes how D. gallinae survival and fecundity rates in an in vivo feeding device compared to that of mites fed using an in vitro method. Results showed that survival of fed D. gallinae females and mites overall was greater in vitro, although there was no difference between male survival and fecundity between in vivo and in vitro designs. The in vitro feeding device described therefore has the potential to provide reliable results, comparable to those obtained by in vivo testing, to allow for the rapid screening of D. gallinae antigens. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Screening for personality disorder in incarcerated adolescent boys: preliminary validation of an adolescent version of the standardised assessment of personality – abbreviated scale (SAPAS-AV)

    PubMed Central

    2012-01-01

    Background Personality disorder (PD) is associated with significant functional impairment and an elevated risk of violent and suicidal behaviour. The prevalence of PD in populations of young offenders is likely to be high. However, because the assessment of PD is time-consuming, it is not routinely assessed in this population. A brief screen for the identification of young people who might warrant further detailed assessment of PD could be particularly valuable for clinicians and researchers working in juvenile justice settings. Method We adapted a rapid screen for the identification of PD in adults (Standardised Assessment of Personality – Abbreviated Scale; SAPAS) for use with adolescents and then carried out a study of the reliability and validity of the adapted instrument in a sample of 80 adolescent boys in secure institutions. Participants were administered the screen and shortly after an established diagnostic interview for DSM-IV PDs. Nine days later the screen was readministered. Results A score of 3 or more on the screening interview correctly identified the presence of DSM-IV PD in 86% of participants, yielding a sensitivity and specificity of 0.87 and 0.86 respectively. Internal consistency was modest but comparable to the original instrument. 9-days test-retest reliability for the total score was excellent. Convergent validity correlations with the total number of PD criteria were large. Conclusion This study provides preliminary evidence of the validity, reliability, and usefulness of the screen in secure institutions for adolescent male offenders. It can be used in juvenile offender institutions with limited resources, as a brief, acceptable, staff-administered routine screen to identify individuals in need of further assessment of PD or by researchers conducting epidemiological surveys. PMID:22846474

  20. The inter and intra rater reliability of the Netball Movement Screening Tool.

    PubMed

    Reid, Duncan A; Vanweerd, Rebecca J; Larmer, Peter J; Kingstone, Rachel

    2015-05-01

    To establish the inter- and intra-rater reliability of the Netball Movement Screening Tool, for screening adolescent female netball players. Inter- and intra-rater reliability study. Forty secondary school netball players were recruited to take part in the study. Twenty subjects were screened simultaneously and independently by two raters to ascertain inter-rater agreement. Twenty subjects were scored by rater one on two occasions, separated by a week, to ascertain intra-rater agreement. Inter and intra-rater agreement was assessed utilising the two-way mixed inter class correlation coefficient and weighted kappa statistics. No significant demographic differences were found between the inter and intra-rater groups of subjects. Inter class correlation coefficients' demonstrated excellent inter-rater (two-way mixed inter class correlation coefficients 0.84, standard error of measurement 0.25) and intra-rater (two-way mixed inter class correlation coefficients 0.96, standard error of measurement 0.13) reliability for the overall Netball Movement Screening Tool score and substantial-excellent (two-way mixed inter class correlation coefficients 1.0-0.65) inter-rater and substantial-excellent intra-rater (two-way mixed inter class correlation coefficients 0.96-0.79) reliability for the component scores of the Netball Movement Screening Tool. Kappa statistic showed substantial to poor inter-rater (k=0.75-0.32) and intra-rater (k=0.77-0.27) agreement for individual tests of the NMST. The Netball Movement Screening Tool may be a reliable screening tool for adolescent netball players; however the individual test scores have low reliability. The screening tool can be administered reliably by raters with similar levels of training in the tool but variable clinical experience. On-going research needs to be undertaken to ascertain whether the Netball Movement Screening Tool is a valid tool in ascertaining increased injury risk for netball players. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. Spectroscopic and Spectrometric Methods Used for the Screening of Certain Herbal Food Supplements Suspected of Adulteration

    PubMed Central

    Mateescu, Cristina; Popescu, Anca Mihaela; Radu, Gabriel Lucian; Onisei, Tatiana; Raducanu, Adina Elena

    2017-01-01

    Purpose: This study was carried out in order to find a reliable method for the fast detection of adulterated herbal food supplements with sexual enhancement claims. As some herbal products are advertised as "all natural", their "efficiency" is often increased by addition of active pharmaceutical ingredients such as PDE-5 inhibitors, which can be a real health threat for the consumer. Methodes: Adulterants, potentially present in 50 herbal food supplements with sexual improvement claims, were detected using 2 spectroscopic methods - Raman and Fourier Transform Infrared - known for reliability, reproductibility, and an easy sample preparation. GC-MS technique was used to confirm the potential adulterants spectra. Results: About 22% (11 out of 50 samples) of herbal food supplements with sexual enhancement claims analyzed by spectroscopic and spectrometric methods proved to be "enriched" with active pharmaceutical compounds such as: sildenafil and two of its analogues, tadalafil and phenolphthalein. The occurence of phenolphthalein could be the reason for the non-relevant results obtained by FTIR method in some samples. 91% of the adulterated herbal food supplements were originating from China. Conclusion: The results of this screening highlighted the necessity for an accurate analysis of all alleged herbal aphrodisiacs on the Romanian market. This is a first such a screening analysis carried out on herbal food supplements with sexual enhancement claims. PMID:28761827

  2. Spectroscopic and Spectrometric Methods Used for the Screening of Certain Herbal Food Supplements Suspected of Adulteration.

    PubMed

    Mateescu, Cristina; Popescu, Anca Mihaela; Radu, Gabriel Lucian; Onisei, Tatiana; Raducanu, Adina Elena

    2017-06-01

    Purpose: This study was carried out in order to find a reliable method for the fast detection of adulterated herbal food supplements with sexual enhancement claims. As some herbal products are advertised as "all natural", their "efficiency" is often increased by addition of active pharmaceutical ingredients such as PDE-5 inhibitors, which can be a real health threat for the consumer. Methodes: Adulterants, potentially present in 50 herbal food supplements with sexual improvement claims, were detected using 2 spectroscopic methods - Raman and Fourier Transform Infrared - known for reliability, reproductibility, and an easy sample preparation. GC-MS technique was used to confirm the potential adulterants spectra. Results: About 22% (11 out of 50 samples) of herbal food supplements with sexual enhancement claims analyzed by spectroscopic and spectrometric methods proved to be "enriched" with active pharmaceutical compounds such as: sildenafil and two of its analogues, tadalafil and phenolphthalein. The occurence of phenolphthalein could be the reason for the non-relevant results obtained by FTIR method in some samples. 91% of the adulterated herbal food supplements were originating from China. Conclusion: The results of this screening highlighted the necessity for an accurate analysis of all alleged herbal aphrodisiacs on the Romanian market. This is a first such a screening analysis carried out on herbal food supplements with sexual enhancement claims.

  3. Turkish translation and adaptation of Champion's Health Belief Model Scales for breast cancer mammography screening.

    PubMed

    Yilmaz, Meryem; Sayin, Yazile Yazici

    2014-07-01

    To examine the translation and adaptation process from English to Turkish and the validity and reliability of the Champion's Health Belief Model Scales for Mammography Screening. Its aim (1) is to provide data about and (2) to assess Turkish women's attitudes and behaviours towards mammography. The proportion of women who have mammography is lower in Turkey. The Champion's Health Belief Model Scales for Mammography Screening-Turkish version can be helpful to determine Turkish women's health beliefs, particularly about mammography. Cross-sectional design was used to collect survey data from Turkish women: classical measurement method. The Champion's Health Belief Model Scales for Mammography Screening was translated from English to Turkish. Again, it was back translated into English. Later, the meaning and clarity of the scale items were evaluated by a bilingual group representing the culture of the target population. Finally, the tool was evaluated by two bilingual professional researchers in terms of content validity, translation validity and psychometric estimates of the validity and reliability. The analysis included a total of 209 Turkish women. The validity of the scale was confirmed by confirmatory factor analysis and criterion-related validity testing. The Champion's Health Belief Model Scales for Mammography Screening aligned to four factors that were coherent and relatively independent of each other. There was a statistically significant relationship among all of the subscale items: the positive and high correlation of the total item test score and high Cronbach's α. The scale has a strong stability over time: the Champion's Health Belief Model Scales for Mammography Screening demonstrated acceptable preliminary values of reliability and validity. The Champion's Health Belief Model Scales for Mammography Screening is both a reliable and valid instrument that can be useful in measuring the health beliefs of Turkish women. It can be used to provide data about healthcare practices required for mammography screening and breast cancer prevention. This scale will show nurses that nursing intervention planning is essential for increasing Turkish women's participation in mammography screening. © 2013 John Wiley & Sons Ltd.

  4. A screening mammography program. Staying alive and making it work.

    PubMed

    Monsees, B S; Destouet, J M

    1992-01-01

    The success of a mammography screening program requires thorough planning. A dependably high volume and a streamlined efficient operation are essential to survival of the program. Factors that warrant consideration prior to designing such a program include the following: Distinction between screening and diagnostic mammography examinations. Selection of a site that will meet the needs of the community and yet provide a consistently high volume. Low examination cost for screening mammography coupled with a detailed financial analysis and reappraisal on an ongoing basis. A customized marketing program that incorporates methods to increase awareness, compliance, and utilization by women and referring physicians. Well-trained, efficient, and dedicated personnel. An operation that is designed for rapid throughput and expeditious patient flow. An efficient plan for film handling, interpretation, reporting, and storage. Timely communication of examination results. A reliable mechanism for follow-up evaluation and outcome data collection. Establishment of a consistent and reliable quality assurance program and the production of high quality mammograms.

  5. High throughput ADME screening: practical considerations, impact on the portfolio and enabler of in silico ADME models.

    PubMed

    Hop, Cornelis E C A; Cole, Mark J; Davidson, Ralph E; Duignan, David B; Federico, James; Janiszewski, John S; Jenkins, Kelly; Krueger, Suzanne; Lebowitz, Rebecca; Liston, Theodore E; Mitchell, Walter; Snyder, Mark; Steyn, Stefan J; Soglia, John R; Taylor, Christine; Troutman, Matt D; Umland, John; West, Michael; Whalen, Kevin M; Zelesky, Veronica; Zhao, Sabrina X

    2008-11-01

    Evaluation and optimization of drug metabolism and pharmacokinetic data plays an important role in drug discovery and development and several reliable in vitro ADME models are available. Recently higher throughput in vitro ADME screening facilities have been established in order to be able to evaluate an appreciable fraction of synthesized compounds. The ADME screening process can be dissected in five distinct steps: (1) plate management of compounds in need of in vitro ADME data, (2) optimization of the MS/MS method for the compounds, (3) in vitro ADME experiments and sample clean up, (4) collection and reduction of the raw LC-MS/MS data and (5) archival of the processed ADME data. All steps will be described in detail and the value of the data on drug discovery projects will be discussed as well. Finally, in vitro ADME screening can generate large quantities of data obtained under identical conditions to allow building of reliable in silico models.

  6. [Methicillin resistance detection in Staphylococcus aureus: comparison between conventional methods and MRSA-Screen latex agglutination technique].

    PubMed

    Soloaga, R; Corso, A; Gagetti, P; Faccone, D; Galas, M

    2004-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a significant pathogen that has emerged over the last four decades, causing both nosocomial and community-acquired infections. Rapid and accurate detection of methicillin resistance in S. aureus is important for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of MRSA strains. We evaluated the efficiency of conventional methods for detection of methicillin resistance such as the disk diffusion, agar dilution, oxacillin agar screen test, and the latex agglutination test MRSA-Screen latex, in 100 isolates of S. aureus, 79 mecA positive and 21 mecA negative. The MRSA-Screen latex (Denka Seiken, Niigata, Japón), is a latex agglutination method that detects the presence of PLP-2a, product of mecA gene in S. aureus. The PCR of the mecA gene was used as the "gold standard" for the evaluation of the different methods tested. The percentages of sensitivity and specificity were as follows: disk difusión 97 and 100%, agar dilution 97 and 95%, oxacillin agar screen test 100 and 100%, and MRSA-Screen latex, 100 and 100 %. All methods presented high sensitivity and specificity, but MRSA-Screen latex had the advantage of giving a reliable result, equivalent to PCR, in only 15 minutes.

  7. Benchmarking Data Sets for the Evaluation of Virtual Ligand Screening Methods: Review and Perspectives.

    PubMed

    Lagarde, Nathalie; Zagury, Jean-François; Montes, Matthieu

    2015-07-27

    Virtual screening methods are commonly used nowadays in drug discovery processes. However, to ensure their reliability, they have to be carefully evaluated. The evaluation of these methods is often realized in a retrospective way, notably by studying the enrichment of benchmarking data sets. To this purpose, numerous benchmarking data sets were developed over the years, and the resulting improvements led to the availability of high quality benchmarking data sets. However, some points still have to be considered in the selection of the active compounds, decoys, and protein structures to obtain optimal benchmarking data sets.

  8. Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.

    PubMed

    Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina

    2013-11-01

    To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.

  9. Reliability Analysis of RSG-GAS Primary Cooling System to Support Aging Management Program

    NASA Astrophysics Data System (ADS)

    Deswandri; Subekti, M.; Sunaryo, Geni Rina

    2018-02-01

    Multipurpose Research Reactor G.A. Siwabessy (RSG-GAS) which has been operating since 1987 is one of the main facilities on supporting research, development and application of nuclear energy programs in BATAN. Until now, the RSG-GAS research reactor has been successfully operated safely and securely. However, because it has been operating for nearly 30 years, the structures, systems and components (SSCs) from the reactor would have started experiencing an aging phase. The process of aging certainly causes a decrease in reliability and safe performances of the reactor, therefore the aging management program is needed to resolve the issues. One of the programs in the aging management is to evaluate the safety and reliability of the system and also screening the critical components to be managed.One method that can be used for such purposes is the Fault Tree Analysis (FTA). In this papers FTA method is used to screening the critical components in the RSG-GAS Primary Cooling System. The evaluation results showed that the primary isolation valves are the basic events which are dominant against the system failure.

  10. [SCREENING OF NUTRITIONAL STATUS AMONG ELDERLY PEOPLE AT FAMILY MEDICINE].

    PubMed

    Račić, M; Ivković, N; Kusmuk, S

    2015-11-01

    The prevalence of malnutrition in elderly is high. Malnutrition or risk of malnutrition can be detected by use of nutritional screening or assessment tools. This systematic review aimed to identify tools that would be reliable, valid, sensitive and specific for nutritional status screening in patients older than 65 at family medicine. The review was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Studies were retrieved using MEDLINE (via Ovid), PubMed and Cochrane Library electronic databases and by manual searching of relevant articles listed in reference list of key publications. The electronic databases were searched using defined key words adapted to each database and using MESH terms. Manual revision of reviews and original articles was performed using Electronic Journals Library. Included studies involved development and validation of screening tools in the community-dwelling elderly population. The tools, subjected to validity and reliability testing for use in the community-dwelling elderly population were Mini Nutritional Assessment (MNA), Mini Nutritional Assessment-Short Form (MNA-SF), Nutrition Screening Initiative (NSI), which includes DETERMINE list, Level I and II Screen, Seniors in the Community: Risk Evaluation for Eating, and Nutrition (SCREEN I and SCREEN II), Subjective Global Assessment (SGA), Nutritional Risk Index (NRI), and Malaysian and South African tool. MNA and MNA-SF appear to have highest reliability and validity for screening of community-dwelling elderly, while the reliability and validity of SCREEN II are good. The authors conclude that whilst several tools have been developed, most have not undergone extensive testing to demonstrate their ability to identify nutritional risk. MNA and MNA-SF have the highest reliability and validity for screening of nutritional status in the community-dwelling elderly, and the reliability and validity of SCREEN II are satisfactory. These instruments also contain all three nutritional status indicators and are practical for use in family medicine. However, the gold standard for screening cannot be set because testing of reliability and continuous validation in the study with a higher level of evidence need to be conducted in family medicine.

  11. One Question, Multiple Answers: Biochemical and Biophysical Screening Methods Retrieve Deviating Fragment Hit Lists.

    PubMed

    Schiebel, Johannes; Radeva, Nedyalka; Köster, Helene; Metz, Alexander; Krotzky, Timo; Kuhnert, Maren; Diederich, Wibke E; Heine, Andreas; Neumann, Lars; Atmanene, Cedric; Roecklin, Dominique; Vivat-Hannah, Valérie; Renaud, Jean-Paul; Meinecke, Robert; Schlinck, Nina; Sitte, Astrid; Popp, Franziska; Zeeb, Markus; Klebe, Gerhard

    2015-09-01

    Fragment-based lead discovery is gaining momentum in drug development. Typically, a hierarchical cascade of several screening techniques is consulted to identify fragment hits which are then analyzed by crystallography. Because crystal structures with bound fragments are essential for the subsequent hit-to-lead-to-drug optimization, the screening process should distinguish reliably between binders and non-binders. We therefore investigated whether different screening methods would reveal similar collections of putative binders. First we used a biochemical assay to identify fragments that bind to endothiapepsin, a surrogate for disease-relevant aspartic proteases. In a comprehensive screening approach, we then evaluated our 361-entry library by using a reporter-displacement assay, saturation-transfer difference NMR, native mass spectrometry, thermophoresis, and a thermal shift assay. While the combined results of these screening methods retrieve 10 of the 11 crystal structures originally predicted by the biochemical assay, the mutual overlap of individual hit lists is surprisingly low, highlighting that each technique operates on different biophysical principles and conditions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Using pre-screening methods for an effective and reliable site characterization at megasites.

    PubMed

    Algreen, Mette; Kalisz, Mariusz; Stalder, Marcel; Martac, Eugeniu; Krupanek, Janusz; Trapp, Stefan; Bartke, Stephan

    2015-10-01

    This paper illustrates the usefulness of pre-screening methods for an effective characterization of polluted sites. We applied a sequence of site characterization methods to a former Soviet military airbase with likely fuel and benzene, toluene, ethylbenzene, and xylene (BTEX) contamination in shallow groundwater and subsoil. The methods were (i) phytoscreening with tree cores; (ii) soil gas measurements for CH4, O2, and photoionization detector (PID); (iii) direct-push with membrane interface probe (MIP) and laser-induced fluorescence (LIF) sensors; (iv) direct-push sampling; and (v) sampling from soil and from groundwater monitoring wells. Phytoscreening and soil gas measurements are rapid and inexpensive pre-screening methods. Both indicated subsurface pollution and hot spots successfully. The direct-push sensors yielded 3D information about the extension and the volume of the subsurface plume. This study also expanded the applicability of tree coring to BTEX compounds and tested the use of high-resolution direct-push sensors for light hydrocarbons. Comparison of screening results to results from conventional soil and groundwater sampling yielded in most cases high rank correlation and confirmed the findings. The large-scale application of non- or low-invasive pre-screening can be of help in directing and focusing the subsequent, more expensive investigation methods. The rapid pre-screening methods also yielded useful information about potential remediation methods. Overall, we see several benefits of a stepwise screening and site characterization scheme, which we propose in conclusion.

  13. Psychometric properties of the Vulnerability to Abuse Screening Scale for screening abuse of older adults

    PubMed Central

    Dantas, Raquel Batista; Oliveira, Graziella Lage; Silveira, Andréa Maria

    2017-01-01

    ABSTRACT OBJECTIVE Adapt and evaluate the psychometric properties of the Vulnerability to Abuse Screening Scale to identify risk of domestic violence against older adults in Brazil. METHODS The instrument was adapted and validated in a sample of 151 older adults from a geriatric reference center in the municipality of Belo Horizonte, State of Minas Gerais, in 2014. We collected sociodemographic, clinical, and abuse-related information, and verified reliability by reproducibility in a sample of 55 older people, who underwent re-testing of the instrument seven days after the first application. Descriptive and comparative analyses were performed for all variables, with a significance level of 5%. The construct validity was analyzed by the principal components method with a tetrachoric correlation matrix, the reliability of the scale by the weighted Kappa (Kp) statistic, and the internal consistency by the Kuder-Richardson estimator formula 20 (KR-20). RESULTS The average age of the participants was 72.1 years (DP = 6.96; 95%CI 70.94–73.17), with a maximum of 92 years, and they were predominantly female (76.2%; 95%CI 69.82–83.03). When analyzing the relationship between the scores of the Vulnerability to Abuse Screening Scale, categorized by presence (score > 3) or absence (score < 3) of vulnerability to abuse, with clinical and health conditions, we found statistically significant differences for self-perception of health (p = 0.002), depressive symptoms (p = 0.000), and presence of rheumatism (p = 0.003). There were no statistically significant differences between sexes. The Vulnerability to Abuse Screening Scale acceptably evaluated validity in the transcultural adaptation process, demonstrating dimensionality coherent with the original proposal (four factors). In the internal consistency analysis, the instrument presented good results (KR-20 = 0.69) and the reliability via reproducibility was considered excellent for the global scale (Kp = 0.92). CONCLUSIONS The Vulnerability to Abuse Screening Scale proved to be a valid instrument with good psychometric capacity for screening domestic abuse against older adults in Brazil. PMID:28423137

  14. A permutation-based non-parametric analysis of CRISPR screen data.

    PubMed

    Jia, Gaoxiang; Wang, Xinlei; Xiao, Guanghua

    2017-07-19

    Clustered regularly-interspaced short palindromic repeats (CRISPR) screens are usually implemented in cultured cells to identify genes with critical functions. Although several methods have been developed or adapted to analyze CRISPR screening data, no single specific algorithm has gained popularity. Thus, rigorous procedures are needed to overcome the shortcomings of existing algorithms. We developed a Permutation-Based Non-Parametric Analysis (PBNPA) algorithm, which computes p-values at the gene level by permuting sgRNA labels, and thus it avoids restrictive distributional assumptions. Although PBNPA is designed to analyze CRISPR data, it can also be applied to analyze genetic screens implemented with siRNAs or shRNAs and drug screens. We compared the performance of PBNPA with competing methods on simulated data as well as on real data. PBNPA outperformed recent methods designed for CRISPR screen analysis, as well as methods used for analyzing other functional genomics screens, in terms of Receiver Operating Characteristics (ROC) curves and False Discovery Rate (FDR) control for simulated data under various settings. Remarkably, the PBNPA algorithm showed better consistency and FDR control on published real data as well. PBNPA yields more consistent and reliable results than its competitors, especially when the data quality is low. R package of PBNPA is available at: https://cran.r-project.org/web/packages/PBNPA/ .

  15. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    PubMed

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent test-retest reliability for nearly all questions. However, when a reporter changes from pre- to postintervention, differences may reflect poor reliability or different subjective experiences rather than true change.

  16. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective

    PubMed Central

    Shterenshis, Michael

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes. PMID:29138741

  17. Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective.

    PubMed

    Shterenshis, Michael

    2017-01-01

    Medical infrared thermography (IT) produces an image of the infrared waves emitted by the human body as part of the thermoregulation process that can vary in intensity based on the health of the person. This review analyzes recent developments in the use of infrared thermography as a screening and diagnostic tool in clinical and nonclinical settings, and identifies possible future routes for improvement of the method. Currently, infrared thermography is not considered to be a fully reliable diagnostic method. If standard infrared protocol is established and a normative database is available, infrared thermography may become a reliable method for detecting inflammatory processes.

  18. Screening for learning disabilities in young adult career counseling.

    PubMed

    Kasler, Jon; Fawcett, Angela

    2009-01-01

    The Strengths and Weaknesses Academic Profile (SWAP) was constructed in Israel in response to the local need of career counselors for a valid, reliable, comprehensive, parsimonious, and computerized screening device for identifying those likely to be at risk of learning disabilities (LD). The method chosen was self-report. A set of cognitive items was written and divided into seven scales: reading, writing, attention and memory, computation, English as a foreign language (EFL), study skills, and self-image. The screening tool was validated on a research sample in Sheffield, UK, based on comparison of the results obtained from the screening with the results of standardized diagnosis of learning disabilities administered to the respondents. The questionnaire was administered to 39 students, half of them diagnosed for dyslexia and half tested and found to be free of dyslexia. Results indicate that SWAP is a reliable and valid questionnaire, with a classification power of approximately 90%. The questionnaire is now widely used in Israel, where an Internet site has been constructed to administer the questionnaire and provide immediate and direct results.

  19. Development and Validation of a POSIT-Short Form: Screening for Problem Behaviors among Adolescents at Risk for Substance Use.

    ERIC Educational Resources Information Center

    Danseco, Evangeline R.; Marques, Paul R.

    2002-01-01

    The Problem-Oriented Screening Instrument for Teenagers (POSIT) screens for multiple problems among adolescents at risk for substance use. A shortened version of the POSIT was developed, using factor analysis, and correlational and reliability analyses. The POSIT-SF shows potential for a reliable and cost-efficient screen for youth with substance…

  20. The Evaluation of a Screening Tool for Children with an Intellectual Disability: The Child and Adolescent Intellectual Disability Screening Questionnaire

    ERIC Educational Resources Information Center

    McKenzie, Karen; Paxton, Donna; Murray, George; Milanesi, Paula; Murray, Aja Louise

    2012-01-01

    The study outlines the evaluation of an intellectual disability screening tool, the "Child and Adolescent Intellectual Disability Screening Questionnaire" ("CAIDS-Q"), with two age groups. A number of aspects of the reliability and validity of the "CAIDS-Q" were assessed for these two groups, including inter-rater reliability, convergent and…

  1. Score Reliability of Adolescent Alcohol Screening Measures: A Meta-Analytic Inquiry

    ERIC Educational Resources Information Center

    Shields, Alan L.; Campfield, Delia C.; Miller, Christopher S.; Howell, Ryan T.; Wallace, Kimberly; Weiss, Roger D.

    2008-01-01

    This study describes the reliability reporting practices in empirical studies using eight adolescent alcohol screening tools and characterizes and explores variability in internal consistency estimates across samples. Of 119 observed administrations of these instruments, 40 (34%) reported usable reliability information. The Personal Experience…

  2. Screening of groundwater remedial alternatives for brownfield sites: a comprehensive method integrated MCDA with numerical simulation.

    PubMed

    Li, Wei; Zhang, Min; Wang, Mingyu; Han, Zhantao; Liu, Jiankai; Chen, Zhezhou; Liu, Bo; Yan, Yan; Liu, Zhu

    2018-06-01

    Brownfield sites pollution and remediation is an urgent environmental issue worldwide. The screening and assessment of remedial alternatives is especially complex owing to its multiple criteria that involves technique, economy, and policy. To help the decision-makers selecting the remedial alternatives efficiently, the criteria framework conducted by the U.S. EPA is improved and a comprehensive method that integrates multiple criteria decision analysis (MCDA) with numerical simulation is conducted in this paper. The criteria framework is modified and classified into three categories: qualitative, semi-quantitative, and quantitative criteria, MCDA method, AHP-PROMETHEE (analytical hierarchy process-preference ranking organization method for enrichment evaluation) is used to determine the priority ranking of the remedial alternatives and the solute transport simulation is conducted to assess the remedial efficiency. A case study was present to demonstrate the screening method in a brownfield site in Cangzhou, northern China. The results show that the systematic method provides a reliable way to quantify the priority of the remedial alternatives.

  3. Challenges for Detecting Valproic Acid in a Nontargeted Urine Drug Screening Method.

    PubMed

    Pope, Jeffrey D; Black, Marion J; Drummer, Olaf H; Schneider, Hans G

    2017-08-01

    Valproic acid (VPA) is a widely prescribed medicine, and acute toxicity is possible. As such, it should be included in any nontargeted urine drug screening method. In many published liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) methods, VPA is usually measured using a pseudo-multiple reaction monitoring (MRM) transition. We investigate a simple ultra-high-performance liquid chromatography-quadrupole time-of-flight (QTof) approach to detect the presence of VPA with more confidence. Three commercially sourced VPA metabolites were characterized and added to a nontargeted high-resolution MS urine drug screening method. All analyses were performed on a Waters Xevo G2-XS LC-QTof in negative electrospray ionization mode. The mass detector was operated in MS mode, and data were processed with UNIFI software. Sixty-eight patient urine samples, which were previously identified by a well-established gas chromatography-MS method as containing VPA, were analyzed on the Waters Xevo G2-XS LC-QTof, to validate this approach. VPA metabolite standards were characterized, and their detection data were added to the broad drug screening library. VPA metabolites were readily detectable in the urine of patients taking VPA. The inclusion of characterized VPA metabolites provides a simple and reliable method enabling the detection of VPA in nontargeted urine drug screening.

  4. HPTLC-FLD-SERS as a facile and reliable screening tool: Exemplarily shown with tyramine in cheese.

    PubMed

    Wang, Liao; Xu, Xue-Ming; Chen, Yi-Sheng; Ren, Jie; Liu, Yun-Tao

    2018-04-01

    The serious cytotoxicity of tyramine attracted marked attention as it induced necrosis of human intestinal cells. This paper presented a novel and facile high performance thin-layer chromatography (HPTLC) method tailored for screening tyramine in cheese. Separation was performed on glass backed silica gel plates, using methanol/ethyl acetate/ammonia (6/4/1 v/v/v) as the mobile phase. Special efforts were focused on optimizing conditions (substrate preparation, laser wavelength, salt types and concentrations) of surface enhanced Raman spectroscopy (SERS) measurements directly on plates after derivatization, which enabled molecule-specific identification of targeted bands. In parallel, fluorescent densitometry (FLD) scanning at 380

  5. Fluorophore Metal-Organic Complexes: High-Throughput Optical Screening for Aprotic Electrochemical Systems.

    PubMed

    Park, Sung Hyeon; Choi, Chang Hyuck; Lee, Seung Yong; Woo, Seong Ihl

    2017-02-13

    Combinatorial optical screening of aprotic electrocatalysts has not yet been achieved primarily due to H + -associated mechanisms of fluorophore modulation. We have overcome this problem by using fluorophore metal-organic complexes. In particular, eosin Y and quinine can be coordinated with various metallic cations (e.g., Li + , Na + , Mg 2+ , Zn 2+ , and Al 3+ ) in aprotic solvents, triggering changes in their fluorescent properties. These interactions have been used in a reliable screening method to determine oxygen reduction/evolution reaction activities of 100 Mn-based binary catalysts for the aprotic Li-air battery.

  6. Evaluation of a Rapid Method for Screening Heat Stress Tolerance Using Three Korean Wheat (Triticum aestivum L.) Cultivars.

    PubMed

    Truong, Hai An; Jeong, Chan Young; Lee, Won Je; Lee, Byung Cheon; Chung, Namhyun; Kang, Chon-Sik; Cheong, Young-Keun; Hong, Suk-Whan; Lee, Hojoung

    2017-07-19

    Thermotolerance in plants is a topic of concern given the current trends in global warming. Here, we aimed to develop a rapid and reproducible screening method for selection of heat stress-tolerant wheat varieties to expedite the breeding process. We tested the robustness of the screen in three Korean wheat cultivars, "BackJung", "KeumKang", and "ChoKyeong". We showed that 4-day-old seedlings of "KeumKang" had the highest survival rates after a 45 °C treatment for 20 h. Moreover, the ability to retain chlorophyll and antioxidant activity was also highest in "KeumKang". The increase in malondialdehyde content in "ChoKyeong" indicated that this cultivar showed the greatest damage after heat stress. Collectively, our results showed that "KeumKang" is the most heat-tolerant cultivar of the three examined. In conclusion, the most reliable and rapid screening method in our investigation was survival rate examined at lethal temperature.

  7. Peptide and protein biomarkers for type 1 diabetes mellitus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Qibin; Metz, Thomas O.

    A method for identifying persons with increased risk of developing type 1 diabetes mellitus, or having type I diabetes mellitus, utilizing selected biomarkers described herein either alone or in combination. The present disclosure allows for broad based, reliable, screening of large population bases. Also provided are arrays and kits that can be used to perform such methods.

  8. Peptide and protein biomarkers for type 1 diabetes mellitus

    DOEpatents

    Zhang, Qibin; Metz, Thomas O.

    2014-06-10

    A method for identifying persons with increased risk of developing type 1 diabetes mellitus, or having type I diabetes mellitus, utilizing selected biomarkers described herein either alone or in combination. The present disclosure allows for broad based, reliable, screening of large population bases. Also provided are arrays and kits that can be used to perform such methods.

  9. Overview of Non-Volatile Testing and Screening Methods

    NASA Technical Reports Server (NTRS)

    Irom, Farokh

    2001-01-01

    Testing methods for memories and non-volatile memories have become increasingly sophisticated as they become denser and more complex. High frequency and faster rewrite times as well as smaller feature sizes have led to many testing challenges. This paper outlines several testing issues posed by novel memories and approaches to testing for radiation and reliability effects. We discuss methods for measurements of Total Ionizing Dose (TID).

  10. Screening for anthracnose disease resistance in strawberry using a detached leaf assay

    USDA-ARS?s Scientific Manuscript database

    Inoculation of detached strawberry leaves with Colletotrichum species may provide a rapid, non-destructive method of identifying anthracnose resistant germplasm. The reliability and validity of assessing disease severity is critical to disease management decisions. We inoculated detached strawberr...

  11. Reliability Characterization of Digital Microcircuits - Investigation of an In-Process Oxide Reliability Screening Method

    DTIC Science & Technology

    1993-04-01

    CLASSIFICATION 18. SECURITY CLASSIFICATION 19. SECURIlY CLASSIFICATION 20. UMITATION OF ABSTRACT OF REPORT OF THIS PAGE OF ABSTRACT UNCLASSIFIED UNCLASSIFIED...with the silicon underneath, growing a thin nitride layer. This layer of Si 3 N 4 , if not completely removed, will retard oxidation in the area...C. Shatas, K. C. Saraswat and J. D. Meindl, "Interfacial and Breakdown Characteristics of MOS Devices with Rapidly Grown Ultrathin SiO Gate

  12. Improving compound-protein interaction prediction by building up highly credible negative samples.

    PubMed

    Liu, Hui; Sun, Jianjiang; Guan, Jihong; Zheng, Jie; Zhou, Shuigeng

    2015-06-15

    Computational prediction of compound-protein interactions (CPIs) is of great importance for drug design and development, as genome-scale experimental validation of CPIs is not only time-consuming but also prohibitively expensive. With the availability of an increasing number of validated interactions, the performance of computational prediction approaches is severely impended by the lack of reliable negative CPI samples. A systematic method of screening reliable negative sample becomes critical to improving the performance of in silico prediction methods. This article aims at building up a set of highly credible negative samples of CPIs via an in silico screening method. As most existing computational models assume that similar compounds are likely to interact with similar target proteins and achieve remarkable performance, it is rational to identify potential negative samples based on the converse negative proposition that the proteins dissimilar to every known/predicted target of a compound are not much likely to be targeted by the compound and vice versa. We integrated various resources, including chemical structures, chemical expression profiles and side effects of compounds, amino acid sequences, protein-protein interaction network and functional annotations of proteins, into a systematic screening framework. We first tested the screened negative samples on six classical classifiers, and all these classifiers achieved remarkably higher performance on our negative samples than on randomly generated negative samples for both human and Caenorhabditis elegans. We then verified the negative samples on three existing prediction models, including bipartite local model, Gaussian kernel profile and Bayesian matrix factorization, and found that the performances of these models are also significantly improved on the screened negative samples. Moreover, we validated the screened negative samples on a drug bioactivity dataset. Finally, we derived two sets of new interactions by training an support vector machine classifier on the positive interactions annotated in DrugBank and our screened negative interactions. The screened negative samples and the predicted interactions provide the research community with a useful resource for identifying new drug targets and a helpful supplement to the current curated compound-protein databases. Supplementary files are available at: http://admis.fudan.edu.cn/negative-cpi/. © The Author 2015. Published by Oxford University Press.

  13. Validity of radiographic assessment of the knee joint space using automatic image analysis.

    PubMed

    Komatsu, Daigo; Hasegawa, Yukiharu; Kojima, Toshihisa; Seki, Taisuke; Ikeuchi, Kazuma; Takegami, Yasuhiko; Amano, Takafumi; Higuchi, Yoshitoshi; Kasai, Takehiro; Ishiguro, Naoki

    2016-09-01

    The present study investigated whether there were differences between automatic and manual measurements of the minimum joint space width (mJSW) on knee radiographs. Knee radiographs of 324 participants in a systematic health screening were analyzed using the following three methods: manual measurement of film-based radiographs (Manual), manual measurement of digitized radiographs (Digital), and automatic measurement of digitized radiographs (Auto). The mean mJSWs on the medial and lateral sides of the knees were determined using each method, and measurement reliability was evaluated using intra-class correlation coefficients. Measurement errors were compared between normal knees and knees with radiographic osteoarthritis. All three methods demonstrated good reliability, although the reliability was slightly lower with the Manual method than with the other methods. On the medial and lateral sides of the knees, the mJSWs were the largest in the Manual method and the smallest in the Auto method. The measurement errors of each method were significantly larger for normal knees than for radiographic osteoarthritis knees. The mJSW measurements are more accurate and reliable with the Auto method than with the Manual or Digital method, especially for normal knees. Therefore, the Auto method is ideal for the assessment of the knee joint space.

  14. Integrating preconcentrator heat controller

    DOEpatents

    Bouchier, Francis A.; Arakaki, Lester H.; Varley, Eric S.

    2007-10-16

    A method and apparatus for controlling the electric resistance heating of a metallic chemical preconcentrator screen, for example, used in portable trace explosives detectors. The length of the heating time-period is automatically adjusted to compensate for any changes in the voltage driving the heating current across the screen, for example, due to gradual discharge or aging of a battery. The total deposited energy in the screen is proportional to the integral over time of the square of the voltage drop across the screen. Since the net temperature rise, .DELTA.T.sub.s, of the screen, from beginning to end of the heating pulse, is proportional to the total amount of heat energy deposited in the screen during the heating pulse, then this integral can be calculated in real-time and used to terminate the heating current when a pre-set target value has been reached; thereby providing a consistent and reliable screen temperature rise, .DELTA.T.sub.s, from pulse-to-pulse.

  15. Measuring lip force by oral screens. Part 1: Importance of screen size and individual variability.

    PubMed

    Wertsén, Madeleine; Stenberg, Manne

    2017-06-01

    To reduce drooling and facilitate food transport in rehabilitation of patients with oral motor dysfunction, lip force can be trained using an oral screen. Longitudinal studies evaluating the effect of training require objective methods. The aim of this study was to evaluate a method for measuring lip strength, to investigate normal values and fluctuation of lip force in healthy adults on 1 occasion and over time, to study how the size of the screen affects the force, to evaluate the most appropriate measure of reliability, and to identify force performed in relation to gender. Three different sizes of oral screens were used to measure the lip force for 24 healthy adults on 3 different occasions, during a period of 6 months, using an apparatus based on strain gauge. The maximum lip force as evaluated with this method depends on the area of the screen size. By calculating the projected area of the screen, the lip force could be normalized to an oral screen pressure quantity expressed in kPa, which can be used for comparing measurements from screens with different sizes. Both the mean value and standard deviation were shown to vary between individuals. The study showed no differences regarding gender and only small variation with age. Normal variation over time (months) may be up to 3 times greater than the standard error of measurement at a certain occasion. The lip force increases in relation to the projected area of the screen. No general standard deviation can be assigned to the method and all measurements should be analyzed individually based on oral screen pressure to compensate for different screen sizes.

  16. A Method for the Automatic Detection of Insect Clutter in Doppler-Radar Returns.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luke,E.; Kollias, P.; Johnson, K.

    2006-06-12

    The accurate detection and removal of insect clutter from millimeter wavelength cloud radar (MMCR) returns is of high importance to boundary layer cloud research (e.g., Geerts et al., 2005). When only radar Doppler moments are available, it is difficult to produce a reliable screening of insect clutter from cloud returns because their distributions overlap. Hence, screening of MMCR insect clutter has historically involved a laborious manual process of cross-referencing radar moments against measurements from other collocated instruments, such as lidar. Our study looks beyond traditional radar moments to ask whether analysis of recorded Doppler spectra can serve as the basismore » for reliable, automatic insect clutter screening. We focus on the MMCR operated by the Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) program at its Southern Great Plains (SGP) facility in Oklahoma. Here, archiving of full Doppler spectra began in September 2003, and during the warmer months, a pronounced insect presence regularly introduces clutter into boundary layer returns.« less

  17. Score Reliability and Construct Validity of the Flinn Performance Screening Tool for Adults With Symptoms of Carpal Tunnel Syndrome

    PubMed Central

    Flinn, Sharon R.; Pease, William S.; Freimer, Miriam L.

    2013-01-01

    OBJECTIVE We investigated the psychometric properties of the Flinn Performance Screening Tool (FPST) for people referred with symptoms of carpal tunnel syndrome (CTS). METHOD An occupational therapist collected data from 46 participants who completed the Functional Status Scale (FSS) and FPST after the participants’ nerve conduction velocity study to test convergent and contrasted-group validity. RESULTS Seventy-four percent of the participants had abnormal nerve conduction studies. Cronbach’s α coefficients for subscale and total scores of the FPST ranged from .96 to .98. Intrarater reliability for six shared items of the FSS and the FPST was supported by high agreement (71%) and a fair κ statistic (.36). Strong to moderate positive relationships were found between the FSS and FPST scores. Functional status differed significantly among severe, mild, and negative CTS severity groups. CONCLUSION The FPST shows adequate psychometric properties as a client-centered screening tool for occupational performance of people referred for symptoms of CTS. PMID:22549598

  18. Tuneable surface enhanced Raman spectroscopy hyphenated to chemically derivatized thin-layer chromatography plates for screening histamine in fish.

    PubMed

    Xie, Zhengjun; Wang, Yang; Chen, Yisheng; Xu, Xueming; Jin, Zhengyu; Ding, Yunlian; Yang, Na; Wu, Fengfeng

    2017-09-01

    Reliable screening of histamine in fish was of urgent importance for food safety. This work presented a highly selective surface enhanced Raman spectroscopy (SERS) method mediated by thin-layer chromatography (TLC), which was tailored for identification and quantitation of histamine. Following separation and derivatization with fluram, plates were assayed with SERS, jointly using silver nanoparticle and NaCl. The latter dramatically suppressed the masking effect caused by excessive fluram throughout the plate, thus offering clear baseline and intensive Raman fingerprints specific to the analyte. Under optimized conditions, the usability of this method was validated by identifying the structural fingerprints of both targeted and unknown compounds in fish samples. Meanwhile, the quantitative results of this method agreed with those by an HPLC method officially suggested by EU for histamine determination. Showing remarkable cost-efficiency and user-friendliness, this facile TLC-SERS method was indeed screening-oriented and may be more attractive to controlling laboratories of limited resource. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Health literacy screening instruments for eHealth applications: a systematic review.

    PubMed

    Collins, Sarah A; Currie, Leanne M; Bakken, Suzanne; Vawdrey, David K; Stone, Patricia W

    2012-06-01

    To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms "health", "literacy", "computer-based," and "psychometrics". All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in seven different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Only English language health literacy assessment instruments were reviewed and analyzed. Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments' content and methodologies for computer-based health literacy screening and assessment. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Health Literacy Screening Instruments for eHealth Applications: A Systematic Review

    PubMed Central

    Collins, Sarah A.; Currie, Leanne M.; Bakken, Suzanne; Vawdrey, David K.; Stone, Patricia W.

    2012-01-01

    Objective To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. Design The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms “health”, “literacy”, “computer-based,” and “psychometrics”. All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Results Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in 7 different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Limitations Only English language health literacy assessment instruments were reviewed and analyzed. Conclusions Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments’ content and methodologies for computer-based health literacy screening and assessment. PMID:22521719

  1. Dynamics of subcellular compartmentalization of steroid receptors in living cells as a strategic screening method to determine the biological impact of suspected endocrine disruptors.

    PubMed

    Tyagi, Rakesh Kumar

    2003-04-01

    Although a number of screening methods being used for identifying potential endocrine disruptors have generated a wealth of information, a search for alternative combination of methods is still needed to overcome experimental artefacts. There are no generally accepted or validated screening methods for monitoring and studying impact of environmental endocrine disruptors. Also, no single assay can accurately predict all the deleterious effects of endocrine disruptors. For this reason various environmental protection agencies, mainly European and US, have urged that a battery of tests in current use need to be designed to assess their adequacy in detecting the effects of endocrine disruptors. Some details about endocrine disruptors and screening programs can be found at http://www.epa.gov/scipoly/oscpendo/whatis.htm. Several studies in recent years have used fusion proteins between steroid receptors (estrogen, androgen, progesterone, etc.) and green fluorescent protein (GFP) that can serve as an alternative potent screening method to study intracellular dynamics of receptors in living cells. An approach employing nucleocytoplasmic trafficking of steroid receptors as a parameter in response to potential xenobiotic chemicals in living cells may prove to be promising in terms of being direct, fast, reliable, simple and inexpensive. Copyright 2003 Elsevier Science Ltd.

  2. The Screening Test for Emotional Problems-Parent Report (STEP-P): Studies of Reliability and Validity

    ERIC Educational Resources Information Center

    Erford, Bradley T.; Alsamadi, Silvana C.

    2012-01-01

    Score reliability and validity of parent responses concerning their 10- to 17-year-old students were analyzed using the Screening Test for Emotional Problems-Parent Report (STEP-P), which assesses a variety of emotional problems classified under the Individuals with Disabilities Education Improvement Act. Score reliability, convergent, and…

  3. THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS)

    PubMed Central

    aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim

    2017-01-01

    Background/purpose The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. Methods The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the ‘pure’ intra-rater (intra-occasion) reliability for those movements. Results Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Conclusions Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate the relationship between test score and subsequent injury. The present results indicate acceptable reliability for this purpose; however, room for further development of the intra-rater reliability exists for some of the individual sub-tests. Level of evidence 2b PMID:28217416

  4. A comparative trial of paper-and-pencil versus computer administration of the Quality of Life in Reflux and Dyspepsia (QOLRAD) questionnaire.

    PubMed

    Kleinman, L; Leidy, N K; Crawley, J; Bonomi, A; Schoenfeld, P

    2001-02-01

    Although most health-related quality of life questionnaires are self-administered by means of paper and pencil, new technologies for automated computer administration are becoming more readily available. Novel methods of instrument administration must be assessed for score equivalence in addition to consistency in reliability and validity. The present study compared the psychometric characteristics (score equivalence and structure, internal consistency, and reproducibility reliability and construct validity) of the Quality of Life in Reflux And Dyspepsia (QOLRAD) questionnaire when self-administered by means of paper and pencil versus touch-screen computer. The influence of age, education, and prior experience with computers on score equivalence was also examined. This crossover trial randomized 134 patients with gastroesophageal reflux disease to 1 of 2 groups: paper-and-pencil questionnaire administration followed by computer administration or computer administration followed by use of paper and pencil. To minimize learning effects and respondent fatigue, administrations were scheduled 3 days apart. A random sample of 32 patients participated in a 1-week reproducibility evaluation of the computer-administered QOLRAD. QOLRAD scores were equivalent across the 2 methods of administration regardless of subject age, education, and prior computer use. Internal consistency levels were very high (alpha = 0.93-0.99). Interscale correlations were strong and generally consistent across methods (r = 0.7-0.87). Correlations between the QOLRAD and Short Form 36 (SF-36) were high, with no significant differences by method. Test-retest reliability of the computer-administered QOLRAD was also very high (ICC = 0.93-0.96). Results of the present study suggest that the QOLRAD is reliable and valid when self-administered by means of computer touch-screen or paper and pencil.

  5. Accurate quasiparticle calculation of x-ray photoelectron spectra of solids

    NASA Astrophysics Data System (ADS)

    Aoki, Tsubasa; Ohno, Kaoru

    2018-05-01

    It has been highly desired to provide an accurate and reliable method to calculate core electron binding energies (CEBEs) of crystals and to understand the final state screening effect on a core hole in high resolution x-ray photoelectron spectroscopy (XPS), because the ΔSCF method cannot be simply used for bulk systems. We propose to use the quasiparticle calculation based on many-body perturbation theory for this problem. In this study, CEBEs of band-gapped crystals, silicon, diamond, β-SiC, BN, and AlP, are investigated by means of the GW approximation (GWA) using the full ω integration and compared with the preexisting XPS data. The screening effect on a deep core hole is also investigated in detail by evaluating the relaxation energy (RE) from the core and valence contributions separately. Calculated results show that not only the valence electrons but also the core electrons have an important contribution to the RE, and the GWA have a tendency to underestimate CEBEs due to the excess RE. This underestimation can be improved by introducing the self-screening correction to the GWA. The resulting C1s, B1s, N1s, Si2p, and Al2p CEBEs are in excellent agreement with the experiments within 1 eV absolute error range. The present self-screening corrected GW approach has the capability to achieve the highly accurate prediction of CEBEs without any empirical parameter for band-gapped crystals, and provide a more reliable theoretical approach than the conventional ΔSCF-DFT method.

  6. Accurate quasiparticle calculation of x-ray photoelectron spectra of solids.

    PubMed

    Aoki, Tsubasa; Ohno, Kaoru

    2018-05-31

    It has been highly desired to provide an accurate and reliable method to calculate core electron binding energies (CEBEs) of crystals and to understand the final state screening effect on a core hole in high resolution x-ray photoelectron spectroscopy (XPS), because the ΔSCF method cannot be simply used for bulk systems. We propose to use the quasiparticle calculation based on many-body perturbation theory for this problem. In this study, CEBEs of band-gapped crystals, silicon, diamond, β-SiC, BN, and AlP, are investigated by means of the GW approximation (GWA) using the full ω integration and compared with the preexisting XPS data. The screening effect on a deep core hole is also investigated in detail by evaluating the relaxation energy (RE) from the core and valence contributions separately. Calculated results show that not only the valence electrons but also the core electrons have an important contribution to the RE, and the GWA have a tendency to underestimate CEBEs due to the excess RE. This underestimation can be improved by introducing the self-screening correction to the GWA. The resulting C1s, B1s, N1s, Si2p, and Al2p CEBEs are in excellent agreement with the experiments within 1 eV absolute error range. The present self-screening corrected GW approach has the capability to achieve the highly accurate prediction of CEBEs without any empirical parameter for band-gapped crystals, and provide a more reliable theoretical approach than the conventional ΔSCF-DFT method.

  7. [Methodological study for detecting gene mutation of family with genotyping of compound heterogenicity of SEA alpha-thalassemia 1 and HbCS].

    PubMed

    Chen, Jian; Luo, Bi; Qi, Zhu; Huo, Pei-Dan; Zhang, Quan-Sheng; Wang, Hong

    2010-06-01

    This study was aimed to establish a method of PCR combination with PCR-RFLP for detecting the South-East Asian (SEA) deletion type alpha-thalassemia 1 and non-deletion mutation of Hb Constant Spring (CS), and to investigate the application value of this method. For the members of the families with alpha-thalassemia, SEA deletion mutation was detected by PCR, then the HbCS point mutation was screened by PCR-RFLP. The results indicated that 15 carriers with alpha-thalassemia (--(SEA)/) were found in 19 members from 7 families, and 2 families with genotype of --(SEA)/alpha(CS)alpha were screened out successfully. It is concluded that the PCR combination with PCR-RFLP is a simple, rapid, and reliable method for screening HbH disease with genotype of --(SEA)/alpha(CS)alpha.

  8. Importance of the pharmacological profile of the bound ligand in enrichment on nuclear receptors: toward the use of experimentally validated decoy ligands.

    PubMed

    Lagarde, Nathalie; Zagury, Jean-François; Montes, Matthieu

    2014-10-27

    The evaluation of virtual ligand screening methods is of major importance to ensure their reliability. Taking into account the agonist/antagonist pharmacological profile should improve the quality of the benchmarking data sets since ligand binding can induce conformational changes in the nuclear receptor structure and such changes may vary according to the agonist/antagonist ligand profile. We indeed found that splitting the agonist and antagonist ligands into two separate data sets for a given nuclear receptor target significantly enhances the quality of the evaluation. The pharmacological profile of the ligand bound in the binding site of the target structure was also found to be an additional critical parameter. We also illustrate that active compound data sets for a given pharmacological activity can be used as a set of experimentally validated decoy ligands for another pharmacological activity to ensure a reliable and challenging evaluation of virtual screening methods.

  9. New method of extracting information of arterial oxygen saturation based on ∑ | 𝚫 |

    NASA Astrophysics Data System (ADS)

    Dai, Wenting; Lin, Ling; Li, Gang

    2017-04-01

    Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.

  10. New method of extracting information of arterial oxygen saturation based on ∑|𝚫 |

    NASA Astrophysics Data System (ADS)

    Wenting, Dai; Ling, Lin; Gang, Li

    2017-04-01

    Noninvasive detection of oxygen saturation with near-infrared spectroscopy has been widely used in clinics. In order to further enhance its detection precision and reliability, this paper proposes a method of time domain absolute difference summation (∑|Δ|) based on a dynamic spectrum. In this method, the ratio of absolute differences between intervals of two differential sampling points at the same moment on logarithm photoplethysmography signals of red and infrared light was obtained in turn, and then they obtained a ratio sequence which was screened with a statistical method. Finally, use the summation of the screened ratio sequence as the oxygen saturation coefficient Q. We collected 120 reference samples of SpO2 and then compared the result of two methods, which are ∑|Δ| and peak-peak. Average root-mean-square errors of the two methods were 3.02% and 6.80%, respectively, in the 20 cases which were selected randomly. In addition, the average variance of Q of the 10 samples, which were obtained by the new method, reduced to 22.77% of that obtained by the peak-peak method. Comparing with the commercial product, the new method makes the results more accurate. Theoretical and experimental analysis indicates that the application of the ∑|Δ| method could enhance the precision and reliability of oxygen saturation detection in real time.

  11. SCREENING FOR PTSD AMONG INCARCERATED MEN

    PubMed Central

    WOLFF, NANCY; GREGORY CHUGO, M; SHI, JING; HUENING, JESSICA; FRUEH, B. CHRISTOPHER

    2014-01-01

    Trauma exposure is overrepresented in incarcerated male populations and is linked to psychiatric morbidity, particularly posttraumatic stress disorder (PTSD). This study tests the feasibility, reliability, and validity of using computer-administered interviewing (CAI) versus orally administered interviewing (OAI) to screen for PTSD among incarcerated men. A 2 × 2 factorial design was used to randomly assign 592 incarcerated men to screening modality. Findings indicate that computer screening was feasible. Compared with OAI, CAI produced equally reliable screening information on PTSD symptoms, with test–retest intraclass correlations for the PTSD Checklist (PCL) total score ranging from .774 to .817, and the Clinician-Administered PTSD scale and PCL scores were significantly correlated for OAI and CAI. These findings indicate that data on PTSD symptoms can be reliably and validly obtained from CAI technology, increasing the efficiency by which incarcerated populations can be screened for PTSD, and those at risk can be identified for treatment. PMID:25673900

  12. Reliability and Validity of the Work and Well-Being Inventory (WBI) for Employees.

    PubMed

    Vendrig, A A; Schaafsma, F G

    2018-06-01

    Purpose The purpose of this study is to measure the psychometric properties of the Work and Wellbeing Inventory (WBI) (in Dutch: VAR-2), a screening tool that is used within occupational health care and rehabilitation. Our research question focused on the reliability and validity of this inventory. Methods Over the years seven different samples of workers, patients and sick listed workers varying in size between 89 and 912 participants (total: 2514), were used to measure the test-retest reliability, the internal consistency, the construct and concurrent validity, and the criterion and predictive validity. Results The 13 scales displayed good internal consistency and test-retest reliability. The constructive validity of the WBI could clearly be demonstrated in both patients and healthy workers. Confirmative factor analyses revealed a CFI >.90 for all scales. The depression scale predicted future work absenteeism (>6 weeks) because of a common mental disorder in healthy workers. The job strain scale and the illness behavior scale predicted long term absenteeism (>3 months) in workers with short-term absenteeism. The illness behavior scale moderately predicted return to work in rehab patients attending an intensive multidisciplinary program. Conclusions The WBI is a valid and reliable tool for occupational health practitioners to screen for risk factors for prolonged or future sickness absence. With this tool they will have reliable indications for further advice and interventions to restore the work ability.

  13. A simplified high-throughput method for pyrethroid knock-down resistance (kdr) detection in Anopheles gambiae

    PubMed Central

    Lynd, Amy; Ranson, Hilary; McCall, P J; Randle, Nadine P; Black, William C; Walker, Edward D; Donnelly, Martin J

    2005-01-01

    Background A single base pair mutation in the sodium channel confers knock-down resistance to pyrethroids in many insect species. Its occurrence in Anopheles mosquitoes may have important implications for malaria vector control especially considering the current trend for large scale pyrethroid-treated bednet programmes. Screening Anopheles gambiae populations for the kdr mutation has become one of the mainstays of programmes that monitor the development of insecticide resistance. The screening is commonly performed using a multiplex Polymerase Chain Reaction (PCR) which, since it is reliant on a single nucleotide polymorphism, can be unreliable. Here we present a reliable and potentially high throughput method for screening An. gambiae for the kdr mutation. Methods A Hot Ligation Oligonucleotide Assay (HOLA) was developed to detect both the East and West African kdr alleles in the homozygous and heterozygous states, and was optimized for use in low-tech developing world laboratories. Results from the HOLA were compared to results from the multiplex PCR for field and laboratory mosquito specimens to provide verification of the robustness and sensitivity of the technique. Results and Discussion The HOLA assay, developed for detection of the kdr mutation, gives a bright blue colouration for a positive result whilst negative reactions remain colourless. The results are apparent within a few minutes of adding the final substrate and can be scored by eye. Heterozygotes are scored when a sample gives a positive reaction to the susceptible probe and the kdr probe. The technique uses only basic laboratory equipment and skills and can be carried out by anyone familiar with the Enzyme-linked immunosorbent assay (ELISA) technique. A comparison to the multiplex PCR method showed that the HOLA assay was more reliable, and scoring of the plates was less ambiguous. Conclusion The method is capable of detecting both the East and West African kdr alleles in the homozygous and heterozygous states from fresh or dried material using several DNA extraction methods. It is more reliable than the traditional PCR method and may be more sensitive for the detection of heterozygotes. It is inexpensive, simple and relatively safe making it suitable for use in resource-poor countries. PMID:15766386

  14. Ultrasensitive Single Fluorescence-Labeled Probe-Mediated Single Universal Primer-Multiplex-Droplet Digital Polymerase Chain Reaction for High-Throughput Genetically Modified Organism Screening.

    PubMed

    Niu, Chenqi; Xu, Yuancong; Zhang, Chao; Zhu, Pengyu; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2018-05-01

    As genetically modified (GM) technology develops and genetically modified organisms (GMOs) become more available, GMOs face increasing regulations and pressure to adhere to strict labeling guidelines. A singleplex detection method cannot perform the high-throughput analysis necessary for optimal GMO detection. Combining the advantages of multiplex detection and droplet digital polymerase chain reaction (ddPCR), a single universal primer-multiplex-ddPCR (SUP-M-ddPCR) strategy was proposed for accurate broad-spectrum screening and quantification. The SUP increases efficiency of the primers in PCR and plays an important role in establishing a high-throughput, multiplex detection method. Emerging ddPCR technology has been used for accurate quantification of nucleic acid molecules without a standard curve. Using maize as a reference point, four heterologous sequences ( 35S, NOS, NPTII, and PAT) were selected to evaluate the feasibility and applicability of this strategy. Surprisingly, these four genes cover more than 93% of the transgenic maize lines and serve as preliminary screening sequences. All screening probes were labeled with FAM fluorescence, which allows the signals from the samples with GMO content and those without to be easily differentiated. This fiveplex screening method is a new development in GMO screening. Utilizing an optimal amplification assay, the specificity, limit of detection (LOD), and limit of quantitation (LOQ) were validated. The LOD and LOQ of this GMO screening method were 0.1% and 0.01%, respectively, with a relative standard deviation (RSD) < 25%. This method could serve as an important tool for the detection of GM maize from different processed, commercially available products. Further, this screening method could be applied to other fields that require reliable and sensitive detection of DNA targets.

  15. Biofilm forming ability of bacteria isolated from necrotic roots canals of teeth

    NASA Astrophysics Data System (ADS)

    Alwan, Merriam Ghadhanfar; Usup, Gires; Heng, Lee Yook; Ahmad, Asmat

    2018-04-01

    The growth of microbes in biofilms are associated with repeated and chronic human infections and are extremely resistant to antimicrobial agents. The purpose of this study was to determine the diversity of bacteria from necrotic roots canals of teeth and to detect their biofilm formation ability. A total of 42 bacterial isolates were isolated and identified as belonging to 11 genera. These are Enterococcus sp. (21.4%) followed by Streptococcus sp. (16.8%), Bacillus sp. (11.9%), Peptostreptococcus sp. (9.5%), Staphylococcus sp. (9.5%), Bacteroides sp. (7.1%), Clostridium sp. (7.1%), Actinomyces sp. (7.1%), Fusobacterium sp. (4.76%), Provotella sp. (2.4%) and Chromobacterium sp. (2.4%). Three screening methods for biofilm forming ability were used. Congo Red Agar method (CRA), Tube method (TM) and Microtitre Plate (MTP). From the results, MTP method is a more reliable and quantitative method for the screening and detection of microorganism's ability to form biofilm. This method can be recommended and suggested as a general screening method for the detection of biofilm forming bacteria isolated from roots canals of teeth.

  16. The Reliability of Randomly Generated Math Curriculum-Based Measurements

    ERIC Educational Resources Information Center

    Strait, Gerald G.; Smith, Bradley H.; Pender, Carolyn; Malone, Patrick S.; Roberts, Jarod; Hall, John D.

    2015-01-01

    "Curriculum-Based Measurement" (CBM) is a direct method of academic assessment used to screen and evaluate students' skills and monitor their responses to academic instruction and intervention. Interventioncentral.org offers a math worksheet generator at no cost that creates randomly generated "math curriculum-based measures"…

  17. Direct Identification of On-Bead Peptides Using Surface-Enhanced Raman Spectroscopic Barcoding System for High-Throughput Bioanalysis

    PubMed Central

    Kang, Homan; Jeong, Sinyoung; Koh, Yul; Geun Cha, Myeong; Yang, Jin-Kyoung; Kyeong, San; Kim, Jaehi; Kwak, Seon-Yeong; Chang, Hye-Jin; Lee, Hyunmi; Jeong, Cheolhwan; Kim, Jong-Ho; Jun, Bong-Hyun; Kim, Yong-Kweon; Hong Jeong, Dae; Lee, Yoon-Sik

    2015-01-01

    Recently, preparation and screening of compound libraries remain one of the most challenging tasks in drug discovery, biomarker detection, and biomolecular profiling processes. So far, several distinct encoding/decoding methods such as chemical encoding, graphical encoding, and optical encoding have been reported to identify those libraries. In this paper, a simple and efficient surface-enhanced Raman spectroscopic (SERS) barcoding method using highly sensitive SERS nanoparticles (SERS ID) is presented. The 44 kinds of SERS IDs were able to generate simple codes and could possibly generate more than one million kinds of codes by incorporating combinations of different SERS IDs. The barcoding method exhibited high stability and reliability under bioassay conditions. The SERS ID encoding based screening platform can identify the peptide ligand on the bead and also quantify its binding affinity for specific protein. We believe that our SERS barcoding technology is a promising method in the screening of one-bead-one-compound (OBOC) libraries for drug discovery. PMID:26017924

  18. Direct identification of on-bead peptides using surface-enhanced Raman spectroscopic barcoding system for high-throughput bioanalysis.

    PubMed

    Kang, Homan; Jeong, Sinyoung; Koh, Yul; Geun Cha, Myeong; Yang, Jin-Kyoung; Kyeong, San; Kim, Jaehi; Kwak, Seon-Yeong; Chang, Hye-Jin; Lee, Hyunmi; Jeong, Cheolhwan; Kim, Jong-Ho; Jun, Bong-Hyun; Kim, Yong-Kweon; Hong Jeong, Dae; Lee, Yoon-Sik

    2015-05-28

    Recently, preparation and screening of compound libraries remain one of the most challenging tasks in drug discovery, biomarker detection, and biomolecular profiling processes. So far, several distinct encoding/decoding methods such as chemical encoding, graphical encoding, and optical encoding have been reported to identify those libraries. In this paper, a simple and efficient surface-enhanced Raman spectroscopic (SERS) barcoding method using highly sensitive SERS nanoparticles (SERS ID) is presented. The 44 kinds of SERS IDs were able to generate simple codes and could possibly generate more than one million kinds of codes by incorporating combinations of different SERS IDs. The barcoding method exhibited high stability and reliability under bioassay conditions. The SERS ID encoding based screening platform can identify the peptide ligand on the bead and also quantify its binding affinity for specific protein. We believe that our SERS barcoding technology is a promising method in the screening of one-bead-one-compound (OBOC) libraries for drug discovery.

  19. High-Throughput Method for Automated Colony and Cell Counting by Digital Image Analysis Based on Edge Detection

    PubMed Central

    Choudhry, Priya

    2016-01-01

    Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849

  20. PEM-INST-001: Instructions for Plastic Encapsulated Microcircuit (PEM) Selection, Screening, and Qualification

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander; Sahu, Kusum

    2003-01-01

    Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.

  1. Systematic Screening at the Middle School Level: Score Reliability and Validity of the Student Risk Screening Scale

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Parks, Robin J.; Kalberg, Jemma Robertson; Carter, Erik W.

    2007-01-01

    This article presents findings of two studies, one conducted with middle school students (n = 500) in a rural setting and a second conducted with middle school students (n = 528) in an urban setting, of the reliability and validity of the "Student Risk Screening Scale" (SRSS; Drummond, 1994). Results revealed high internal consistency, test-retest…

  2. SPLICEFINDER – A Fast and Easy Screening Method for Active Protein Trans-Splicing Positions

    PubMed Central

    Eppmann, Simone; Busche, Alena; Dikovskaya, Dina; Dötsch, Volker; Mootz, Henning D.

    2013-01-01

    Split intein enabled protein trans-splicing (PTS) is a powerful method for the ligation of two protein fragments, thereby paving the way for various protein modification or protein function control applications. PTS activity is strongly influenced by the amino acids directly flanking the splice junctions. However, to date no reliable prediction can be made whether or not a split intein is active in a particular foreign extein context. Here we describe SPLICEFINDER, a PCR-based method, allowing fast and easy screening for active split intein insertions in any target protein. Furthermore we demonstrate the applicability of SPLICEFINDER for segmental isotopic labeling as well as for the generation of multi-domain and enzymatically active proteins. PMID:24023792

  3. Item Screening in Graphical Loglinear Rasch Models

    ERIC Educational Resources Information Center

    Kreiner, Svend; Christensen, Karl Bang

    2011-01-01

    In behavioural sciences, local dependence and DIF are common, and purification procedures that eliminate items with these weaknesses often result in short scales with poor reliability. Graphical loglinear Rasch models (Kreiner & Christensen, in "Statistical Methods for Quality of Life Studies," ed. by M. Mesbah, F.C. Cole & M.T.…

  4. Measurement of Nitrogen Mustard Degredation Products by Poly(dimethylsiloxane) Microchip Electrophoresis with Contactless Conductivity Detection

    EPA Science Inventory

    The potential risk of human exposure from an accidental or intentional release of CWAs into a civilian population continues to drive the need for screening and monitoring techniques for these compounds. In particular, rapid and reliable methods for detecting CWAs such as the nitr...

  5. FY12 End of Year Report for NEPP DDR2 Reliability

    NASA Technical Reports Server (NTRS)

    Guertin, Steven M.

    2013-01-01

    This document reports the status of the NASA Electronic Parts and Packaging (NEPP) Double Data Rate 2 (DDR2) Reliability effort for FY2012. The task expanded the focus of evaluating reliability effects targeted for device examination. FY11 work highlighted the need to test many more parts and to examine more operating conditions, in order to provide useful recommendations for NASA users of these devices. This year's efforts focused on development of test capabilities, particularly focusing on those that can be used to determine overall lot quality and identify outlier devices, and test methods that can be employed on components for flight use. Flight acceptance of components potentially includes considerable time for up-screening (though this time may not currently be used for much reliability testing). Manufacturers are much more knowledgeable about the relevant reliability mechanisms for each of their devices. We are not in a position to know what the appropriate reliability tests are for any given device, so although reliability testing could be focused for a given device, we are forced to perform a large campaign of reliability tests to identify devices with degraded reliability. With the available up-screening time for NASA parts, it is possible to run many device performance studies. This includes verification of basic datasheet characteristics. Furthermore, it is possible to perform significant pattern sensitivity studies. By doing these studies we can establish higher reliability of flight components. In order to develop these approaches, it is necessary to develop test capability that can identify reliability outliers. To do this we must test many devices to ensure outliers are in the sample, and we must develop characterization capability to measure many different parameters. For FY12 we increased capability for reliability characterization and sample size. We increased sample size this year by moving from loose devices to dual inline memory modules (DIMMs) with an approximate reduction of 20 to 50 times in terms of per device under test (DUT) cost. By increasing sample size we have improved our ability to characterize devices that may be considered reliability outliers. This report provides an update on the effort to improve DDR2 testing capability. Although focused on DDR2, the methods being used can be extended to DDR and DDR3 with relative ease.

  6. Rapid Screening for Deleted Form of β-thalassemia by Real-Time Quantitative PCR.

    PubMed

    Ke, Liang-Yin; Chang, Jan-Gowth; Chang, Chao-Sung; Hsieh, Li-Ling; Liu, Ta-Chih

    2017-01-01

    Thalassemia is the most common single gene disease in human beings. The prevalence rate of β-thalassemia in Taiwan is approximately 1-3%. Previously methods to reveal and diagnose severe deleted form of α- or β-thalassemia were insufficient and inappropriate for prenatal diagnosis. A real-time quantitative PCR method was set up for rapid screening of the deleted form of β-thalassemia. Our results show that ΔΔCt between deleted form of β-thalassemia and normal individuals were 1.0674 ± 0.0713. On the contrary, mutation form β-thalassemia showed no difference with normal healthy control. The HBB/CCR5 ratio for deleted form of β-thalassemia patients was 0.48, whether normal individuals and mutation form of β-thalassemia was 1.0. This RQ-PCR technique is an alternative rapid screening assay for deleted form of β-thalassemia. In addition, it could also identify undefined type. Our technique by using RQ-PCR to quantify gene copies is a reliable and time-saving method that can screen deleted form of β-thalassemia. © 2016 Wiley Periodicals, Inc.

  7. Construction of reliable protein-protein interaction networks with a new interaction generality measure.

    PubMed

    Saito, Rintaro; Suzuki, Harukazu; Hayashizaki, Yoshihide

    2003-04-12

    Recent screening techniques have made large amounts of protein-protein interaction data available, from which biologically important information such as the function of uncharacterized proteins, the existence of novel protein complexes, and novel signal-transduction pathways can be discovered. However, experimental data on protein interactions contain many false positives, making these discoveries difficult. Therefore computational methods of assessing the reliability of each candidate protein-protein interaction are urgently needed. We developed a new 'interaction generality' measure (IG2) to assess the reliability of protein-protein interactions using only the topological properties of their interaction-network structure. Using yeast protein-protein interaction data, we showed that reliable protein-protein interactions had significantly lower IG2 values than less-reliable interactions, suggesting that IG2 values can be used to evaluate and filter interaction data to enable the construction of reliable protein-protein interaction networks.

  8. A proposed method to investigate reliability throughout a questionnaire

    PubMed Central

    2011-01-01

    Background Questionnaires are used extensively in medical and health care research and depend on validity and reliability. However, participants may differ in interest and awareness throughout long questionnaires, which can affect reliability of their answers. A method is proposed for "screening" of systematic change in random error, which could assess changed reliability of answers. Methods A simulation study was conducted to explore whether systematic change in reliability, expressed as changed random error, could be assessed using unsupervised classification of subjects by cluster analysis (CA) and estimation of intraclass correlation coefficient (ICC). The method was also applied on a clinical dataset from 753 cardiac patients using the Jalowiec Coping Scale. Results The simulation study showed a relationship between the systematic change in random error throughout a questionnaire and the slope between the estimated ICC for subjects classified by CA and successive items in a questionnaire. This slope was proposed as an awareness measure - to assessing if respondents provide only a random answer or one based on a substantial cognitive effort. Scales from different factor structures of Jalowiec Coping Scale had different effect on this awareness measure. Conclusions Even though assumptions in the simulation study might be limited compared to real datasets, the approach is promising for assessing systematic change in reliability throughout long questionnaires. Results from a clinical dataset indicated that the awareness measure differed between scales. PMID:21974842

  9. A proposed method to investigate reliability throughout a questionnaire.

    PubMed

    Wentzel-Larsen, Tore; Norekvål, Tone M; Ulvik, Bjørg; Nygård, Ottar; Pripp, Are H

    2011-10-05

    Questionnaires are used extensively in medical and health care research and depend on validity and reliability. However, participants may differ in interest and awareness throughout long questionnaires, which can affect reliability of their answers. A method is proposed for "screening" of systematic change in random error, which could assess changed reliability of answers. A simulation study was conducted to explore whether systematic change in reliability, expressed as changed random error, could be assessed using unsupervised classification of subjects by cluster analysis (CA) and estimation of intraclass correlation coefficient (ICC). The method was also applied on a clinical dataset from 753 cardiac patients using the Jalowiec Coping Scale. The simulation study showed a relationship between the systematic change in random error throughout a questionnaire and the slope between the estimated ICC for subjects classified by CA and successive items in a questionnaire. This slope was proposed as an awareness measure--to assessing if respondents provide only a random answer or one based on a substantial cognitive effort. Scales from different factor structures of Jalowiec Coping Scale had different effect on this awareness measure. Even though assumptions in the simulation study might be limited compared to real datasets, the approach is promising for assessing systematic change in reliability throughout long questionnaires. Results from a clinical dataset indicated that the awareness measure differed between scales.

  10. Validation of the 4P's Plus screen for substance use in pregnancy validation of the 4P's Plus.

    PubMed

    Chasnoff, I J; Wells, A M; McGourty, R F; Bailey, L K

    2007-12-01

    The purpose of this study is to validate the 4P's Plus screen for substance use in pregnancy. A total of 228 pregnant women enrolled in prenatal care underwent screening with the 4P's Plus and received a follow-up clinical assessment for substance use. Statistical analyses regarding reliability, sensitivity, specificity, and positive and negative predictive validity of the 4Ps Plus were conducted. The overall reliability for the five-item measure was 0.62. Seventy-four (32.5%) of the women had a positive screen. Sensitivity and specificity were very good, at 87 and 76%, respectively. Positive predictive validity was low (36%), but negative predictive validity was quite high (97%). Of the 31 women who had a positive clinical assessment, 45% were using less than 1 day per week. The 4P's Plus reliably and effectively screens pregnant women for risk of substance use, including those women typically missed by other perinatal screening methodologies.

  11. Efficient Sporulation of Saccharomyces cerevisiae in a 96 Multiwell Format.

    PubMed

    Paulissen, Scott M; Huang, Linda S

    2016-09-17

    During times of nutritional stress, Saccharomyces cerevisiae undergoes gametogenesis, known as sporulation. Diploid yeast cells that are starved for nitrogen and carbon will initiate the sporulation process. The process of sporulation includes meiosis followed by spore formation, where the haploid nuclei are packaged into environmentally resistant spores. We have developed methods for the efficient sporulation of budding yeast in 96 multiwell plates, to increase the throughput of screening yeast cells for sporulation phenotypes. These methods are compatible with screening with yeast containing plasmids requiring nutritional selection, when appropriate minimal media is used, or with screening yeast with genomic alterations, when a rich presporulation regimen is used. We find that for this method, aeration during sporulation is critical for spore formation, and have devised techniques to ensure sufficient aeration that are compatible with the 96 multiwell plate format. Although these methods do not achieve the typical ~80% level of sporulation that can be achieved in large-volume flask based experiments, these methods will reliably achieve about 50-60% level of sporulation in small-volume multiwell plates.

  12. Performance of the French version of the 4AT for screening the elderly for delirium in the emergency department.

    PubMed

    Gagné, Anne-Julie; Voyer, Philippe; Boucher, Valérie; Nadeau, Alexandra; Carmichael, Pierre-Hugues; Pelletier, Mathieu; Gouin, Emilie; Berthelot, Simon; Daoust, Raoul; Wilchesky, Machelle; Richard, Hélène; Pelletier, Isabelle; Ballard, Stephanie; Laguë, Antoine; Émond, Marcel

    2018-05-17

    CLINICIAN'S CAPSULE What is known about the topic? Delirium is frequent in older inpatients but often goes undetected. A short tool, the 4 A's Test (4AT), was created and validated for the detection of delirium. What did this study ask? This study compared the performance of the French version of the 4AT (4AT-F) with the Confusion Assessment Method (CAM) for the screening of delirium. What did this study find? The 4AT-F was a fast and reliable screening tool for delirium in the emergency department (ED). Why does this study matter to clinicians? Because of its quick administration time, it allows for systematic screening of patients at risk of delirium and cognitive impairment.

  13. A Systematic Evaluation of Field-Based Screening Methods for the Assessment of Anterior Cruciate Ligament (ACL) Injury Risk.

    PubMed

    Fox, Aaron S; Bonacci, Jason; McLean, Scott G; Spittle, Michael; Saunders, Natalie

    2016-05-01

    Laboratory-based measures provide an accurate method to identify risk factors for anterior cruciate ligament (ACL) injury; however, these methods are generally prohibitive to the wider community. Screening methods that can be completed in a field or clinical setting may be more applicable for wider community use. Examination of field-based screening methods for ACL injury risk can aid in identifying the most applicable method(s) for use in these settings. The objective of this systematic review was to evaluate and compare field-based screening methods for ACL injury risk to determine their efficacy of use in wider community settings. An electronic database search was conducted on the SPORTDiscus™, MEDLINE, AMED and CINAHL databases (January 1990-July 2015) using a combination of relevant keywords. A secondary search of the same databases, using relevant keywords from identified screening methods, was also undertaken. Studies identified as potentially relevant were independently examined by two reviewers for inclusion. Where consensus could not be reached, a third reviewer was consulted. Original research articles that examined screening methods for ACL injury risk that could be undertaken outside of a laboratory setting were included for review. Two reviewers independently assessed the quality of included studies. Included studies were categorized according to the screening method they examined. A description of each screening method, and data pertaining to the ability to prospectively identify ACL injuries, validity and reliability, recommendations for identifying 'at-risk' athletes, equipment and training required to complete screening, time taken to screen athletes, and applicability of the screening method across sports and athletes were extracted from relevant studies. Of 1077 citations from the initial search, a total of 25 articles were identified as potentially relevant, with 12 meeting all inclusion/exclusion criteria. From the secondary search, eight further studies met all criteria, resulting in 20 studies being included for review. Five ACL-screening methods-the Landing Error Scoring System (LESS), Clinic-Based Algorithm, Observational Screening of Dynamic Knee Valgus (OSDKV), 2D-Cam Method, and Tuck Jump Assessment-were identified. There was limited evidence supporting the use of field-based screening methods in predicting ACL injuries across a range of populations. Differences relating to the equipment and time required to complete screening methods were identified. Only screening methods for ACL injury risk were included for review. Field-based screening methods developed for lower-limb injury risk in general may also incorporate, and be useful in, screening for ACL injury risk. Limited studies were available relating to the OSDKV and 2D-Cam Method. The LESS showed predictive validity in identifying ACL injuries, however only in a youth athlete population. The LESS also appears practical for community-wide use due to the minimal equipment and set-up/analysis time required. The Clinic-Based Algorithm may have predictive value for ACL injury risk as it identifies athletes who exhibit high frontal plane knee loads during a landing task, but requires extensive additional equipment and time, which may limit its application to wider community settings.

  14. Optimization of printing techniques for electrochemical biosensors

    NASA Astrophysics Data System (ADS)

    Zainuddin, Ahmad Anwar; Mansor, Ahmad Fairuzabadi Mohd; Rahim, Rosminazuin Ab; Nordin, Anis Nurashikin

    2017-03-01

    Electrochemical biosensors show great promise for point-of-care applications due to their low cost, portability and compatibility with microfluidics. The miniature size of these sensors provides advantages in terms of sensitivity, specificity and allows them to be mass produced in arrays. The most reliable fabrication technique for these sensors is lithography followed by metal deposition using sputtering or chemical vapor deposition techniques. This technique which is usually done in the cleanroom requires expensive masking followed by deposition. Recently, cheaper printing techniques such as screen-printing and ink-jet printing have become popular due to its low cost, ease of fabrication and mask-less method. In this paper, two different printing techniques namely inkjet and screen printing are demonstrated for an electrochemical biosensor. For ink-jet printing technique, optimization of key printing parameters, such as pulse voltages, drop spacing and waveform setting, in-house temperature and cure annealing for obtaining the high quality droplets, are discussed. These factors are compared with screen-printing parameters such as mesh size, emulsion thickness, minimum spacing of lines and curing times. The reliability and reproducibility of the sensors are evaluated using scotch tape test, resistivity and profile-meter measurements. It was found that inkjet printing is superior because it is mask-less, has minimum resolution of 100 µm compared to 200 µm for screen printing and higher reproducibility rate of 90% compared to 78% for screen printing.

  15. Preliminary findings on the reliability and validity of the Cantonese Birmingham Cognitive Screen in patients with acute ischemic stroke

    PubMed Central

    Pan, Xiaoping; Chen, Haobo; Bickerton, Wai-Ling; Lau, Johnny King Lam; Kong, Anthony Pak Hin; Rotshtein, Pia; Guo, Aihua; Hu, Jianxi; Humphreys, Glyn W

    2015-01-01

    Background There are no currently effective cognitive assessment tools for patients who have suffered stroke in the People’s Republic of China. The Birmingham Cognitive Screen (BCoS) has been shown to be a promising tool for revealing patients’ poststroke cognitive deficits in specific domains, which facilitates more individually designed rehabilitation in the long run. Hence we examined the reliability and validity of a Cantonese version BCoS in patients with acute ischemic stroke, in Guangzhou. Method A total of 98 patients with acute ischemic stroke were assessed with the Cantonese version of the BCoS, and an additional 133 healthy individuals were recruited as controls. Apart from the BCoS, the patients also completed a number of external cognitive tests, including the Montreal Cognitive Assessment Test (MoCA), Mini Mental State Examination (MMSE), Albert’s cancellation test, the Rey–Osterrieth Complex Figure Test, and six gesture matching tasks. Cutoff scores for failing each subtest, ie, deficits, were computed based on the performance of the controls. The validity and reliability of the Cantonese BCoS were examined, as well as interrater and test–retest reliability. We also compared the proportions of cases being classified as deficits in controlled attention, memory, character writing, and praxis, between patients with and without spoken language impairment. Results Analyses showed high test–retest reliability and agreement across independent raters on the qualitative aspects of measurement. Significant correlations were observed between the subtests of the Cantonese BCoS and the other external cognitive tests, providing evidence for convergent validity of the Cantonese BCoS. The screen was also able to generate measures of cognitive functions that were relatively uncontaminated by the presence of aphasia. Conclusion This study suggests good reliability and validity of the Cantonese version of the BCoS. The Cantonese BCoS is a very promising tool for the detection of cognitive problems in Cantonese speakers. PMID:26396522

  16. Rapid, Optimized Interactomic Screening

    PubMed Central

    Hakhverdyan, Zhanna; Domanski, Michal; Hough, Loren; Oroskar, Asha A.; Oroskar, Anil R.; Keegan, Sarah; Dilworth, David J.; Molloy, Kelly R.; Sherman, Vadim; Aitchison, John D.; Fenyö, David; Chait, Brian T.; Jensen, Torben Heick; Rout, Michael P.; LaCava, John

    2015-01-01

    We must reliably map the interactomes of cellular macromolecular complexes in order to fully explore and understand biological systems. However, there are no methods to accurately predict how to capture a given macromolecular complex with its physiological binding partners. Here, we present a screen that comprehensively explores the parameters affecting the stability of interactions in affinity-captured complexes, enabling the discovery of physiological binding partners and the elucidation of their functional interactions in unparalleled detail. We have implemented this screen on several macromolecular complexes from a variety of organisms, revealing novel profiles even for well-studied proteins. Our approach is robust, economical and automatable, providing an inroad to the rigorous, systematic dissection of cellular interactomes. PMID:25938370

  17. Buccal Epithelium, Cigarette Smoking, and Lung Cancer: Review of the Literature.

    PubMed

    Saba, Raya; Halytskyy, Oleksandr; Saleem, Nasir; Oliff, Ira A

    2017-01-01

    Lung cancer is currently the leading cause of cancer-related mortality among men and women in the United States, and optimal screening methods are still lacking. The field effect is a well-supported phenomenon wherein a noxious stimulus triggers genetic, epigenetic and molecular changes that are widespread throughout the entire exposed organ system. The buccal epithelium is an easily accessible part of the respiratory tree that has good potential of yielding a surrogate marker for the field effect in cigarette smokers, and thus, a noninvasive, reliable lung cancer screening method. Herein, we review the literature on the relationship between the buccal epithelium, cigarette smoking, and lung cancer. © 2017 S. Karger AG, Basel.

  18. COVD-QOL questionnaire: An adaptation for school vision screening using Rasch analysis

    PubMed Central

    Abu Bakar, Nurul Farhana; Ai Hong, Chen; Pik Pin, Goh

    2012-01-01

    Purpose To adapt the College of Optometrist in Vision Development (COVD-QOL) questionnaire as a vision screening tool for primary school children. Methods An interview session was conducted with children, teachers or guardians regarding visual symptoms of 88 children (45 from special education classes and 43 from mainstream classes) in government primary schools. Data was assessed for response categories, fit items (infit/outfit: 0.6–1.4) and separation reliability (item/person: 0.80). The COVD-QOL questionnaire results were compared with vision assessment in identifying three categories of vision disorders: reduce visual acuity, accommodative response anomaly and convergence insufficiency. Analysis on the screening performance using the simplified version of the questionnaire was evaluated based on receiver-operating characteristic analysis for detection of any type of target conditions for both types of classes. Predictive validity analysis was used a Spearman rank correlation (>0.3). Results Two of the response categories were underutilized and therefore collapsed to the adjacent category and items were reduced to 14. Item separation reliability for the simplified version of the questionnaire was acceptable (0.86) but the person separation reliability was inadequate for special education classes (0.79) similar to mainstream classes (0.78). The discriminant cut-off score of 9 (mainstream classes) and 3 (special education classes) from the 14 items provided sensitivity and specificity of (65% and 54%) and (78% and 80%) with Spearman rank correlation of 0.16 and 0.40 respectively. Conclusion The simplified version of COVD-QOL questionnaire (14-items) performs adequately among children in special education classes suggesting its suitability as a vision screening tool.

  19. Lifetime evaluation of large format CMOS mixed signal infrared devices

    NASA Astrophysics Data System (ADS)

    Linder, A.; Glines, Eddie

    2015-09-01

    New large scale foundry processes continue to produce reliable products. These new large scale devices continue to use industry best practice to screen for failure mechanisms and validate their long lifetime. The Failure-in-Time analysis in conjunction with foundry qualification information can be used to evaluate large format device lifetimes. This analysis is a helpful tool when zero failure life tests are typical. The reliability of the device is estimated by applying the failure rate to the use conditions. JEDEC publications continue to be the industry accepted methods.

  20. Reliability and Validity of the Acanthosis Nigricans Screening Tool for Use in Elementary School-Age Children by School Nurses

    ERIC Educational Resources Information Center

    Scott, Leslie K.; Hall, Lynne M.

    2012-01-01

    The purpose of this study was to test the reliability and validity of an acanthosis nigricans (AN) screening tool for use in elementary school-age children of different ethnic groups. Cross-sectional data were collected via observation of 288, 5- to 12-year-old school-age children. Three nurse clinicians used a 0-4 grade AN screening tool to rate…

  1. Nanoliter-Scale Protein Crystallization and Screening with a Microfluidic Droplet Robot

    PubMed Central

    Zhu, Ying; Zhu, Li-Na; Guo, Rui; Cui, Heng-Jun; Ye, Sheng; Fang, Qun

    2014-01-01

    Large-scale screening of hundreds or even thousands of crystallization conditions while with low sample consumption is in urgent need, in current structural biology research. Here we describe a fully-automated droplet robot for nanoliter-scale crystallization screening that combines the advantages of both automated robotics technique for protein crystallization screening and the droplet-based microfluidic technique. A semi-contact dispensing method was developed to achieve flexible, programmable and reliable liquid-handling operations for nanoliter-scale protein crystallization experiments. We applied the droplet robot in large-scale screening of crystallization conditions of five soluble proteins and one membrane protein with 35–96 different crystallization conditions, study of volume effects on protein crystallization, and determination of phase diagrams of two proteins. The volume for each droplet reactor is only ca. 4–8 nL. The protein consumption significantly reduces 50–500 fold compared with current crystallization stations. PMID:24854085

  2. Nanoliter-scale protein crystallization and screening with a microfluidic droplet robot.

    PubMed

    Zhu, Ying; Zhu, Li-Na; Guo, Rui; Cui, Heng-Jun; Ye, Sheng; Fang, Qun

    2014-05-23

    Large-scale screening of hundreds or even thousands of crystallization conditions while with low sample consumption is in urgent need, in current structural biology research. Here we describe a fully-automated droplet robot for nanoliter-scale crystallization screening that combines the advantages of both automated robotics technique for protein crystallization screening and the droplet-based microfluidic technique. A semi-contact dispensing method was developed to achieve flexible, programmable and reliable liquid-handling operations for nanoliter-scale protein crystallization experiments. We applied the droplet robot in large-scale screening of crystallization conditions of five soluble proteins and one membrane protein with 35-96 different crystallization conditions, study of volume effects on protein crystallization, and determination of phase diagrams of two proteins. The volume for each droplet reactor is only ca. 4-8 nL. The protein consumption significantly reduces 50-500 fold compared with current crystallization stations.

  3. Species identification in meat products: A new screening method based on high resolution melting analysis of cyt b gene.

    PubMed

    Lopez-Oceja, A; Nuñez, C; Baeta, M; Gamarra, D; de Pancorbo, M M

    2017-12-15

    Meat adulteration by substitution with lower value products and/or mislabeling involves economic, health, quality and socio-religious issues. Therefore, identification and traceability of meat species has become an important subject to detect possible fraudulent practices. In the present study the development of a high resolution melt (HRM) screening method for the identification of eight common meat species is reported. Samples from Bos taurus, Ovis aries, Sus scrofa domestica, Equus caballus, Oryctolagus cuniculus, Gallus gallus domesticus, Meleagris gallopavo and Coturnix coturnix were analyzed through the amplification of a 148 bp fragment from the cyt b gene with a universal primer pair in HRM analyses. Melting profiles from each species, as well as from several DNA mixtures of these species and blind samples, allowed a successful species differentiation. The results demonstrated that the HRM method here proposed is a fast, reliable, and low-cost screening technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. DNA extraction techniques compared for accurate detection of genetically modified organisms (GMOs) in maize food and feed products.

    PubMed

    Turkec, Aydin; Kazan, Hande; Karacanli, Burçin; Lucas, Stuart J

    2015-08-01

    In this paper, DNA extraction methods have been evaluated to detect the presence of genetically modified organisms (GMOs) in maize food and feed products commercialised in Turkey. All the extraction methods tested performed well for the majority of maize foods and feed products analysed. However, the highest DNA content was achieved by the Wizard, Genespin or the CTAB method, all of which produced optimal DNA yield and purity for different maize food and feed products. The samples were then screened for the presence of GM elements, along with certified reference materials. Of the food and feed samples, 8 % tested positive for the presence of one GM element (NOS terminator), of which half (4 % of the total) also contained a second element (the Cauliflower Mosaic Virus 35S promoter). The results obtained herein clearly demonstrate the presence of GM maize in the Turkish market, and that the Foodproof GMO Screening Kit provides reliable screening of maize food and feed products.

  5. Global sensitivity analysis for urban water quality modelling: Terminology, convergence and comparison of different methods

    NASA Astrophysics Data System (ADS)

    Vanrolleghem, Peter A.; Mannina, Giorgio; Cosenza, Alida; Neumann, Marc B.

    2015-03-01

    Sensitivity analysis represents an important step in improving the understanding and use of environmental models. Indeed, by means of global sensitivity analysis (GSA), modellers may identify both important (factor prioritisation) and non-influential (factor fixing) model factors. No general rule has yet been defined for verifying the convergence of the GSA methods. In order to fill this gap this paper presents a convergence analysis of three widely used GSA methods (SRC, Extended FAST and Morris screening) for an urban drainage stormwater quality-quantity model. After the convergence was achieved the results of each method were compared. In particular, a discussion on peculiarities, applicability, and reliability of the three methods is presented. Moreover, a graphical Venn diagram based classification scheme and a precise terminology for better identifying important, interacting and non-influential factors for each method is proposed. In terms of convergence, it was shown that sensitivity indices related to factors of the quantity model achieve convergence faster. Results for the Morris screening method deviated considerably from the other methods. Factors related to the quality model require a much higher number of simulations than the number suggested in literature for achieving convergence with this method. In fact, the results have shown that the term "screening" is improperly used as the method may exclude important factors from further analysis. Moreover, for the presented application the convergence analysis shows more stable sensitivity coefficients for the Extended-FAST method compared to SRC and Morris screening. Substantial agreement in terms of factor fixing was found between the Morris screening and Extended FAST methods. In general, the water quality related factors exhibited more important interactions than factors related to water quantity. Furthermore, in contrast to water quantity model outputs, water quality model outputs were found to be characterised by high non-linearity.

  6. Nutrition screening tools: an analysis of the evidence.

    PubMed

    Skipper, Annalynn; Ferguson, Maree; Thompson, Kyle; Castellanos, Victoria H; Porcari, Judy

    2012-05-01

    In response to questions about tools for nutrition screening, an evidence analysis project was developed to identify the most valid and reliable nutrition screening tools for use in acute care and hospital-based ambulatory care settings. An oversight group defined nutrition screening and literature search criteria. A trained analyst conducted structured searches of the literature for studies of nutrition screening tools according to predetermined criteria. Eleven nutrition screening tools designed to detect undernutrition in patients in acute care and hospital-based ambulatory care were identified. Trained analysts evaluated articles for quality using criteria specified by the American Dietetic Association's Evidence Analysis Library. Members of the oversight group assigned quality grades to the tools based on the quality of the supporting evidence, including reliability and validity data. One tool, the NRS-2002, received a grade I, and 4 tools-the Simple Two-Part Tool, the Mini-Nutritional Assessment-Short Form (MNA-SF), the Malnutrition Screening Tool (MST), and Malnutrition Universal Screening Tool (MUST)-received a grade II. The MST was the only tool shown to be both valid and reliable for identifying undernutrition in the settings studied. Thus, validated nutrition screening tools that are simple and easy to use are available for application in acute care and hospital-based ambulatory care settings.

  7. SOS: a screening instrument to identify children with handwriting impairments.

    PubMed

    Van Waelvelde, Hilde; Hellinckx, Tinneke; Peersman, Wim; Smits-Engelsman, Bouwien C M

    2012-08-01

    Poor handwriting has been shown to be associated with developmental disorders such as Developmental Coordination Disorder, Attention Deficit Hyperactivity Disorder, autism, and learning disorders. Handwriting difficulties could lead to academic underachievement and poor self-esteem. Therapeutic intervention has been shown to be effective in treating children with poor handwriting, making early identification critical. The SOS test (Systematic Screening for Handwriting Difficulties) has been developed for this purpose. A child copies a sample of writing within 5 min. Handwriting quality is evaluated using six criteria and writing speed is measured. The Dutch SOS test was administered to 860 Flemish children (7-12 years). Inter- and intrarater reliability was excellent. Test-retest reliability was moderate. A correlation coefficient of 0.70 between SOS and "Concise Assessment Methods of Children Handwriting" test (Dutch version) confirmed convergent validity. The SOS allowed discrimination between typically developing children and children in special education, males and females, and different age groups.

  8. Assessing Reliability of Medical Record Reviews for the Detection of Hospital Adverse Events.

    PubMed

    Ock, Minsu; Lee, Sang-il; Jo, Min-Woo; Lee, Jin Yong; Kim, Seon-Ha

    2015-09-01

    The purpose of this study was to assess the inter-rater reliability and intra-rater reliability of medical record review for the detection of hospital adverse events. We conducted two stages retrospective medical records review of a random sample of 96 patients from one acute-care general hospital. The first stage was an explicit patient record review by two nurses to detect the presence of 41 screening criteria (SC). The second stage was an implicit structured review by two physicians to identify the occurrence of adverse events from the positive cases on the SC. The inter-rater reliability of two nurses and that of two physicians were assessed. The intra-rater reliability was also evaluated by using test-retest method at approximately two weeks later. In 84.2% of the patient medical records, the nurses agreed as to the necessity for the second stage review (kappa, 0.68; 95% confidence interval [CI], 0.54 to 0.83). In 93.0% of the patient medical records screened by nurses, the physicians agreed about the absence or presence of adverse events (kappa, 0.71; 95% CI, 0.44 to 0.97). When assessing intra-rater reliability, the kappa indices of two nurses were 0.54 (95% CI, 0.31 to 0.77) and 0.67 (95% CI, 0.47 to 0.87), whereas those of two physicians were 0.87 (95% CI, 0.62 to 1.00) and 0.37 (95% CI, -0.16 to 0.89). In this study, the medical record review for detecting adverse events showed intermediate to good level of inter-rater and intra-rater reliability. Well organized training program for reviewers and clearly defining SC are required to get more reliable results in the hospital adverse event study.

  9. Validation of the Italian Version of the Caregiver Abuse Screen among Family Caregivers of Older People with Alzheimer's Disease.

    PubMed

    Melchiorre, Maria Gabriella; Di Rosa, Mirko; Barbabella, Francesco; Barbini, Norma; Lattanzio, Fabrizia; Chiatti, Carlos

    2017-01-01

    Introduction . Elder abuse is often a hidden phenomenon and, in many cases, screening practices are difficult to implement among older people with dementia. The Caregiver Abuse Screen (CASE) is a useful tool which is administered to family caregivers for detecting their potential abusive behavior. Objectives . To validate the Italian version of the CASE tool in the context of family caregiving of older people with Alzheimer's disease (AD) and to identify risk factors for elder abuse in Italy. Methods . The CASE test was administered to 438 caregivers, recruited in the Up-Tech study. Validity and reliability were evaluated using Spearman's correlation coefficients, principal-component analysis, and Cronbach's alphas. The association between the CASE and other variables potentially associated with elder abuse was also analyzed. Results . The factor analysis suggested the presence of a single factor, with a strong internal consistency (Cronbach's alpha = 0.86). CASE score was strongly correlated with well-known risk factors of abuse. At multivariate level, main factors associated with CASE total score were caregiver burden and AD-related behavioral disturbances. Conclusions . The Italian version of the CASE is a reliable and consistent screening tool for tackling the risk of being or becoming perpetrators of abuse by family caregivers of people with AD.

  10. Validation of the Italian Version of the Caregiver Abuse Screen among Family Caregivers of Older People with Alzheimer's Disease

    PubMed Central

    Di Rosa, Mirko; Barbabella, Francesco; Barbini, Norma; Chiatti, Carlos

    2017-01-01

    Introduction. Elder abuse is often a hidden phenomenon and, in many cases, screening practices are difficult to implement among older people with dementia. The Caregiver Abuse Screen (CASE) is a useful tool which is administered to family caregivers for detecting their potential abusive behavior. Objectives. To validate the Italian version of the CASE tool in the context of family caregiving of older people with Alzheimer's disease (AD) and to identify risk factors for elder abuse in Italy. Methods. The CASE test was administered to 438 caregivers, recruited in the Up-Tech study. Validity and reliability were evaluated using Spearman's correlation coefficients, principal-component analysis, and Cronbach's alphas. The association between the CASE and other variables potentially associated with elder abuse was also analyzed. Results. The factor analysis suggested the presence of a single factor, with a strong internal consistency (Cronbach's alpha = 0.86). CASE score was strongly correlated with well-known risk factors of abuse. At multivariate level, main factors associated with CASE total score were caregiver burden and AD-related behavioral disturbances. Conclusions. The Italian version of the CASE is a reliable and consistent screening tool for tackling the risk of being or becoming perpetrators of abuse by family caregivers of people with AD. PMID:28265571

  11. Test-retest reliability of the Capute scales for neurodevelopmental screening of a high risk sample: Impact of test-retest interval and degree of neonatal risk.

    PubMed

    McCurdy, M; Bellows, A; Deng, D; Leppert, M; Mahone, E; Pritchard, A

    2015-01-01

    Reliable and valid screening and assessment tools are necessary to identify children at risk for neurodevelopmental disabilities who may require additional services. This study evaluated the test-retest reliability of the Capute Scales in a high-risk sample, hypothesizing adequate reliability across 6- and 12-month intervals. Capute Scales scores (N = 66) were collected via retrospective chart review from a NICU follow-up clinic within a large urban medical center spanning three age-ranges: 12-18, 19-24, and 25-36 months. On average, participants were classified as very low birth weight and premature. Reliability of the Capute Scales was evaluated with intraclass correlation coefficients across length of test-retest interval, age at testing, and degree of neonatal complications. The Capute Scales demonstrated high reliability, regardless of length of test-retest interval (ranging from 6 to 14 months) or age of participant, for all index scores, including overall Developmental Quotient (DQ), language-based skill index (CLAMS) and nonverbal reasoning index (CAT). Linear regressions revealed that greater neonatal risk was related to poorer test-retest reliability; however, reliability coefficients remained strong. The Capute Scales afford clinicians a reliable and valid means of screening and assessing for neurodevelopmental delay within high-risk infant populations.

  12. Psychometric Properties of a Screening Instrument for Domestic Violence in a Sample of Iranian Women

    PubMed Central

    Azadarmaki, Taghi; Kassani, Aziz; Menati, Rostam; Hassanzadeh, Jafar; Menati, Walieh

    2016-01-01

    Background Domestic violence against women is regarded as an important health problem among women and a serious concern in issues related to human rights. To date, a few screening tools for domestic violence exist for Iranian married women, but they assess only some of the domestic violence components. Objectives The present study aimed to design and determine the validity and reliability of a screening instrument for domestic violence in a sample of Iranian women. Materials and Methods The present study was a cross-sectional psychometric evaluation conducted on 350 married women in Ilam, Iran, in 2014. The samples were selected through multistage sampling and the main method was cluster sampling. A 20-item, self-administered questionnaire was validated by exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). An Eigen value > 1 and a loading factor > 0.3 for each component were considered as indices for extracting domestic violence components. Reliability was calculated by test-retest and Cronbach’s alpha. Also, the content validity index (CVI) and content validity ratio (CVR) were used to measure content validity. The data were analyzed using SPSS-13 and LISREL 8.8 software programs. Results The self-administered instrument was completed by 334 women. The CFA and EFA methods confirmed embedding items and the three-factor structure of the instrument including psychological, physical, and sexual violence, which explained 66% of the total variance of the domestic violence. The ICC and Cronbach’s alpha coefficients were > 0.7 for the components of the questionnaire. The test-retest also revealed strong correlations for each of the domestic violence components (r > 0.6). Conclusions The used instrument for measuring domestic violence had desirable validity and reliability and can be used as a suitable instrument in health and social researches in the local population. PMID:27331052

  13. Reliability and Validity of the KIPPPI: An Early Detection Tool for Psychosocial Problems in Toddlers

    PubMed Central

    Kruizinga, Ingrid; Jansen, Wilma; de Haan, Carolien L.; Raat, Hein

    2012-01-01

    Background The KIPPPI (Brief Instrument Psychological and Pedagogical Problem Inventory) is a Dutch questionnaire that measures psychosocial and pedagogical problems in 2-year olds and consists of a KIPPPI Total score, Wellbeing scale, Competence scale, and Autonomy scale. This study examined the reliability, validity, screening accuracy and clinical application of the KIPPPI. Methods Parents of 5959 2-year-old children in the Rotterdam area, the Netherlands, were invited to participate in the study. Parents of 3164 children (53.1% of all invited parents) completed the questionnaire. The internal consistency was evaluated and in subsamples the test-retest reliability and concurrent validity with regard to the Child Behavioral Checklist (CBCL). Discriminative validity was evaluated by comparing scores of parents who worried about their child’s upbringing and parent’s that did not. Screening accuracy of the KIPPPI was evaluated against the CBCL by calculating the Receiver Operating Characteristic (ROC) curves. The clinical application was evaluated by the relation between KIPPPI scores and the clinical decision made by the child health professionals. Results Psychometric properties of the KIPPPI Total score, Wellbeing scale, Competence scale and Autonomy scale were respectively: Cronbach’s alphas: 0.88, 0.86, 0.83, 0.58. Test-retest correlations: 0.80, 0.76, 0.73, 0.60. Concurrent validity was as hypothesised. The KIPPPI was able to discriminate between parents that worried about their child and parents that did not. Screening accuracy was high (>0.90) for the KIPPPI Total score and for the Wellbeing scale. The KIPPPI scale scores and clinical decision of the child health professional were related (p<0.05), indicating a good clinical application. Conclusion The results in this large-scale study of a diverse general population sample support the reliability, validity and clinical application of the KIPPPI Total score, Wellbeing scale and Competence scale. Also, the screening accuracy of the KIPPPI Total score and Wellbeing scale were supported. The Autonomy scale needs further study. PMID:23185388

  14. A simple and rapid radiochemical choline acetyltransferase (ChAT) assay screening test.

    PubMed

    Shiba, Kazuhiro; Ogawa, Kazuma; Kinuya, Seigo; Yajima, Kazuyoshi; Mori, Hirofumi

    2006-10-15

    A simple radiochemical choline acetyltransferase (ChAT) assay screening test was developed by measuring for [(3)H]acetylcholine ([(3)H]ACh) formed from 0.2 mM [(3)H]acetyl-coenzyme A ([(3)H]acetyl-CoA) and 1 mM choline by 0.2 mg of rat brain homogenates containing ChAT into 96-well microplates. A simple and rapid procedure for isolating [(3)H]ACh from the incubation mixture into 96-well microplates was achieved by using a sodium tetraphenylboron (Kalibor) solution (in ethyl acetate, 0.75%, w/v) and a hydrophobic liquid scintillator mixture (1:5, v/v, 0.2 mL) as an extraction solvent. The benefits of this radiochemical method using 96-well microplates are as follows: (1) this method is reliable and reproducible; (2) many samples can be examined at the same time by this method; (3) this method is economical and effective in reducing radioactive waste. The development of a new simple radiochemical ChAT assay screening test is the first stage of development of radiolabeled ChAT mapping agent.

  15. Screening emergency department patients for opioid drug use: A qualitative systematic review.

    PubMed

    Sahota, Preet Kaur; Shastry, Siri; Mukamel, Dana B; Murphy, Linda; Yang, Narisu; Lotfipour, Shahram; Chakravarthy, Bharath

    2018-05-24

    The opioid drug epidemic is a major public health concern and an economic burden in the United States. The purpose of this systematic review is to assess the reliability and validity of screening instruments used in emergency medicine settings to detect opioid use in patients and to assess psychometric data for each screening instrument. PubMed/MEDLINE, PsycINFO, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, Web of Science, Cumulative Index to Nursing and Allied Health Literature and ClinicalTrials.gov were searched for articles published up to May 2018. The extracted articles were independently screened for eligibility by two reviewers. We extracted 1555 articles for initial screening and 95 articles were assessed for full-text eligibility. Six articles were extracted from the full-text assessment. Six instruments were identified from the final article list: Screener and Opioid Assessment for Patients with Pain - Revised; Drug Abuse Screening Test; Opioid Risk Tool; Current Opioid Misuse Measure; an Emergency Medicine Providers Clinician Assessment Questionnaire; and an Emergency Provider Impression Data Collection Form. Screening instrument characteristics, and reliability and validity data were extracted from the six studies. A meta-analysis was not conducted due to heterogeneity between the studies. There is a lack of validity and reliability evidence in all six articles; and sensitivity, specificity and predictive values varied between the different instruments. These instruments cannot be validated for use in emergency medicine settings. There is no clear evidence to state which screening instruments are appropriate for use in detecting opioid use disorders in emergency medicine patients. There is a need for brief, reliable, valid and feasible opioid use screening instruments in the emergency medicine setting. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Composition of a Vision Screen for Servicemembers With Traumatic Brain Injury: Consensus Using a Modified Nominal Group Technique

    PubMed Central

    Finkelstein, Marsha; Llanos, Imelda; Scheiman, Mitchell; Wagener, Sharon Gowdy

    2014-01-01

    Vision impairment is common in the first year after traumatic brain injury (TBI), including among service members whose brain injuries occurred during deployment in Iraq and Afghanistan. Occupational therapy practitioners provide routine vision screening to inform treatment planning and referral to vision specialists, but existing methods are lacking because many tests were developed for children and do not screen for vision dysfunction typical of TBI. An expert panel was charged with specifying the composition of a vision screening protocol for servicemembers with TBI. A modified nominal group technique fostered discussion and objective determinations of consensus. After considering 29 vision tests, the panel recommended a nine-test vision screening that examines functional performance, self-reported problems, far–near acuity, reading, accommodation, convergence, eye alignment and binocular vision, saccades, pursuits, and visual fields. Research is needed to develop reliable, valid, and clinically feasible vision screening protocols to identify TBI-related vision disorders in adults. PMID:25005505

  17. Comparison of diagnostic techniques for the detection of Cryptosporidium oocysts in animal samples

    PubMed Central

    Mirhashemi, Marzieh Ezzaty; Zintl, Annetta; Grant, Tim; Lucy, Frances E.; Mulcahy, Grace; De Waal, Theo

    2015-01-01

    While a large number of laboratory methods for the detection of Cryptosporidium oocysts in faecal samples are now available, their efficacy for identifying asymptomatic cases of cryptosporidiosis is poorly understood. This study was carried out to determine a reliable screening test for epidemiological studies in livestock. In addition, three molecular tests were compared to identify Cryptosporidium species responsible for the infection in cattle, sheep and horses. A variety of diagnostic tests including microscopic (Kinyoun's staining), immunological (Direct Fluorescence Antibody tests or DFAT), enzyme-linked immunosorbent assay (ELISA), and molecular methods (nested PCR) were compared to assess their ability to detect Cryptosporidium in cattle, horse and sheep faecal samples. The results indicate that the sensitivity and specificity of each test is highly dependent on the input samples; while Kinyoun's and DFAT proved to be reliable screening tools for cattle samples, DFAT and PCR analysis (targeted at the 18S rRNA gene fragment) were more sensitive for screening sheep and horse samples. Finally different PCR primer sets targeted at the same region resulted in the preferential amplification of certain Cryptosporidium species when multiple species were present in the sample. Therefore, for identification of Cryptosporidium spp. in the event of asymptomatic cryptosporidiosis, the combination of different 18S rRNA nested PCR primer sets is recommended for further epidemiological applications and also tracking the sources of infection. PMID:25662435

  18. Inter-Rater Reliability for Speech-Language Therapists' Judgement of Oesophageal Abnormality during Oesophageal Visualization

    ERIC Educational Resources Information Center

    Miles, Anna

    2017-01-01

    Background: Oesophageal abnormalities are common findings in a speech-language therapy videofluoroscopy clinic. Fluoroscopic screening involving oropharynx alone fails to identify these patients. Oesophageal screening as an adjunct to videofluoroscopy is gaining popularity. Yet currently, little is known about the reliability of speech and…

  19. Internal Consistency Reliability of the Self-Report Antisocial Process Screening Device

    ERIC Educational Resources Information Center

    Poythress, Norman G.; Douglas, Kevin S.; Falkenbach, Diana; Cruise, Keith; Lee, Zina; Murrie, Daniel C.; Vitacco, Michael

    2006-01-01

    The self-report version of the Antisocial Process Screening Device (APSD) has become a popular measure for assessing psychopathic features in justice-involved adolescents. However, the internal consistency reliability of its component scales (Narcissism, Callous-Unemotional, and Impulsivity) has been questioned in several studies. This study…

  20. A novel automatic quantification method for high-content screening analysis of DNA double strand-break response.

    PubMed

    Feng, Jingwen; Lin, Jie; Zhang, Pengquan; Yang, Songnan; Sa, Yu; Feng, Yuanming

    2017-08-29

    High-content screening is commonly used in studies of the DNA damage response. The double-strand break (DSB) is one of the most harmful types of DNA damage lesions. The conventional method used to quantify DSBs is γH2AX foci counting, which requires manual adjustment and preset parameters and is usually regarded as imprecise, time-consuming, poorly reproducible, and inaccurate. Therefore, a robust automatic alternative method is highly desired. In this manuscript, we present a new method for quantifying DSBs which involves automatic image cropping, automatic foci-segmentation and fluorescent intensity measurement. Furthermore, an additional function was added for standardizing the measurement of DSB response inhibition based on co-localization analysis. We tested the method with a well-known inhibitor of DSB response. The new method requires only one preset parameter, which effectively minimizes operator-dependent variations. Compared with conventional methods, the new method detected a higher percentage difference of foci formation between different cells, which can improve measurement accuracy. The effects of the inhibitor on DSB response were successfully quantified with the new method (p = 0.000). The advantages of this method in terms of reliability, automation and simplicity show its potential in quantitative fluorescence imaging studies and high-content screening for compounds and factors involved in DSB response.

  1. Diagnostic methods of TSH in thyroid screening tests.

    PubMed

    Matyjaszek-Matuszek, Beata; Pyzik, Aleksandra; Nowakowski, Andrzej; Jarosz, Mirosław J

    2013-01-01

    Reliable and quick thyreologic diagnostics, as well as verification of the effectiveness of the therapy undertaken, is of great importance for the state of health of society. The measurement of plasma TSH is the commonly accepted and most sensitive screening test for primary thyroid disorders, which are the most frequent diseases related to the endocrine glands. At present, the available methods for the determination of TSH are characterized by high sensitivity ≤0.01 µIU/ml and lack of cross-reactivity. However, many drugs and substances, as well as pathological conditions, may affect the TSH level. evaluation of contemporary laboratory methods for the determination of TSH and the principles of interpretation of screening tests. In many countries, the TSH test is the only test performed in the diagnostics of thyroid function; nevertheless, it seems that for genuine and objective assessment of thyroid status the TSH level, together with FT4 level, should be absolutely determined, which allows the differentiation and assessment of the intensity of thyroid function disorders and foresee its consequences. The interpretation of TSH results in screening tests is different in such population groups as: children aged under 14, pregnant women, the elderly, and patients with non-thyroidal illnesses. From among currently used laboratory methods for determination of TSH levels, third generation non-isotopic methods are most frequently recommended, especially the method of immunochemiluminescence.

  2. Current issues and future perspectives of gastric cancer screening

    PubMed Central

    Hamashima, Chisato

    2014-01-01

    Gastric cancer remains the second leading cause of cancer death worldwide. About half of the incidence of gastric cancer is observed in East Asian countries, which show a higher mortality than other countries. The effectiveness of 3 new gastric cancer screening techniques, namely, upper gastrointestinal endoscopy, serological testing, and “screen and treat” method were extensively reviewed. Moreover, the phases of development for cancer screening were analyzed on the basis of the biomarker development road map. Several observational studies have reported the effectiveness of endoscopic screening in reducing mortality from gastric cancer. On the other hand, serologic testing has mainly been used for targeting the high-risk group for gastric cancer. To date, the effectiveness of new techniques for gastric cancer screening has remained limited. However, endoscopic screening is presently in the last trial phase of development before their introduction to population-based screening. To effectively introduce new techniques for gastric cancer screening in a community, incidence and mortality reduction from gastric cancer must be initially and thoroughly evaluated by conducting reliable studies. In addition to effectiveness evaluation, the balance of benefits and harms must be carefully assessed before introducing these new techniques for population-based screening. PMID:25320514

  3. Screening of the spine in adolescents: inter- and intra-rater reliability and measurement error of commonly used clinical tests.

    PubMed

    Aartun, Ellen; Degerfalk, Anna; Kentsdotter, Linn; Hestbaek, Lise

    2014-02-10

    Evidence on the reliability of clinical tests used for the spinal screening of children and adolescents is currently lacking. The aim of this study was to determine the inter- and intra-rater reliability and measurement error of clinical tests commonly used when screening young spines. Two experienced chiropractors independently assessed 111 adolescents aged 12-14 years who were recruited from a primary school in Denmark. A standardised examination protocol was used to test inter-rater reliability including tests for scoliosis, hypermobility, general mobility, inter-segmental mobility and end range pain in the spine. Seventy-five of the 111 subjects were re-examined after one to four hours to test intra-rater reliability. Percentage agreement and Cohen's Kappa were calculated for binary variables, and interclass correlation (ICC) and Bland-Altman plots with Limits of Agreement (LoA) were calculated for continuous measures. Inter-rater percentage agreement for binary data ranged from 59.5% to 100%. Kappa ranged from 0.06-1.00. Kappa ≥ 0.40 was seen for elbow, thumb, fifth finger and trunk/hip flexion hypermobility, pain response in inter-segmental mobility and end range pain in lumbar flexion and extension. For continuous data, ICCs ranged from 0.40-0.95. Only forward flexion as measured by finger-to-floor distance reached an acceptable ICC(≥ 0.75). Overall, results for intra-rater reliability were better than for inter-rater reliability but for both components, the LoA were quite wide compared with the range of assessments. Some clinical tests showed good, and some tests poor, reliability when applied in a spinal screening of adolescents. The results could probably be improved by additional training and further test standardization. This is the first step in evaluating the value of these tests for the spinal screening of adolescents. Future research should determine the association between these tests and current and/or future neck and back pain.

  4. Prestack depth migration for complex 2D structure using phase-screen propagators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, P.; Huang, Lian-Jie; Burch, C.

    1997-11-01

    We present results for the phase-screen propagator method applied to prestack depth migration of the Marmousi synthetic data set. The data were migrated as individual common-shot records and the resulting partial images were superposed to obtain the final complete Image. Tests were performed to determine the minimum number of frequency components required to achieve the best quality image and this in turn provided estimates of the minimum computing time. Running on a single processor SUN SPARC Ultra I, high quality images were obtained in as little as 8.7 CPU hours and adequate images were obtained in as little as 4.4more » CPU hours. Different methods were tested for choosing the reference velocity used for the background phase-shift operation and for defining the slowness perturbation screens. Although the depths of some of the steeply dipping, high-contrast features were shifted slightly the overall image quality was fairly insensitive to the choice of the reference velocity. Our jests show the phase-screen method to be a reliable and fast algorithm for imaging complex geologic structures, at least for complex 2D synthetic data where the velocity model is known.« less

  5. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    PubMed Central

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where excellence was not reached. Key points The movement control tests of The Foundation Matrix had acceptable reliability between raters and within raters on different days Agreement between observations made on tests performed real-time and on video recordings was low, indicating poor validity of use of video recordings Some movement evaluation criteria related to specific tests that did not achieve excellent agreement could be modified to improve reliability PMID:25983594

  6. Reliability and Validity of the TIMPSI for Infants With Spinal Muscular Atrophy Type I

    PubMed Central

    Krosschell, Kristin J.; Maczulski, Jo Anne; Scott, Charles; King, Wendy; Hartman, Jill T.; Case, Laura E.; Viazzo-Trussell, Donata; Wood, Janine; Roman, Carolyn A.; Hecker, Eva; Meffert, Marianne; Léveillé, Maude; Kienitz, Krista; Swoboda, Kathryn J.

    2014-01-01

    Purpose This study examined the reliability and validity of the Test of Infant Motor Performance Screening Items (TIMPSI) in infants with type I spinal muscular atrophy (SMA). Methods After training, 12 evaluators scored 4 videos of infants with type I SMA to assess interrater reliability. Intrarater and test-retest reliability was further assessed for 9 evaluators during a SMA type I clinical trial, with 9 evaluators testing a total of 38 infants twice. Relatedness of the TIMPSI score to ability to reach and ventilatory support was also examined. Results Excellent interrater video score reliability was noted (intraclass correlation coefficient, 0.97–0.98). Intrarater reliability was excellent (intraclass correlation coefficient, 0.91–0.98) and test-retest reliability ranged from r = 0.82 to r = 0.95. The TIMPSI score was related to the ability to reach (P ≤ .05). Conclusion The TIMPSI can reliably be used to assess motor function in infants with type I SMA. In addition, the TIMPSI scores are related to the ability to reach, an important functional skill in children with type I SMA. PMID:23542189

  7. A proof-of-concept evaluation of a cloud-based store-and-forward telemedicine app for screening for oral diseases.

    PubMed

    Estai, Mohamed; Kanagasingam, Yogesan; Xiao, Di; Vignarajan, Janardhan; Huang, Boyan; Kruger, Estie; Tennant, Marc

    2016-09-01

    It is widely considered that telemedicine can make positive contributions to dental practice. This study aimed to evaluate a cloud-based telemedicine application for screening for oral diseases. A telemedicine system, based on a store-and-forward method, was developed to work as a platform for data storage. An Android application was developed to facilitate entering demographic details and capturing oral photos. As a proof-of-concept, six volunteers were enrolled in a trial to obtain oral images using smartphone cameras. Following an onsite oral examination, images of participants' teeth were obtained by a trained dental assistant. Oral images were directly uploaded from the smartphone to a cloud-based server via broadband network. The assessments of oral images by offsite dentists were compared with those carried out via face-to-face oral examinations. A complete set of 30 oral images was obtained from all six participants. Out of 192 teeth reviewed, the proportion of ungradable teeth was 8%. Sensitivity and specificity of teledental screening were 57% and 100% respectively. The inter-grader agreement estimated for two examination modalities and between two teledental graders was 70% and 62% respectively. Findings indicate that the proposed system for screening of oral diseases can be implemented to provide a valid and reliable alternative to traditional oral screening. This study provided evidence that a robust system for store-and-forward screening for dental problems can be developed, and leads to the need for further testing of its robustness to confirm the accuracy and reliability of the teledentistry system. © The Author(s) 2015.

  8. FAITH – Fast Assembly Inhibitor Test for HIV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadravová, Romana; Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz; Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague

    Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification ofmore » the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.« less

  9. Practical Disk Diffusion Test for Detecting Group B Streptococcus with Reduced Penicillin Susceptibility▿

    PubMed Central

    Kimura, Kouji; Wachino, Jun-ichi; Kurokawa, Hiroshi; Suzuki, Satowa; Yamane, Kunikazu; Shibata, Naohiro; Arakawa, Yoshichika

    2009-01-01

    Although group B streptococcus (GBS) has been considered to be uniformly susceptible to β-lactams, the presence of GBS with reduced penicillin susceptibility (PRGBS) was recently confirmed genetically. We developed a feasible and reliable method for screening PRGBS in clinical microbiology laboratories using a combination of ceftibuten, oxacillin, and ceftizoxime disks. PMID:19812274

  10. Practical disk diffusion test for detecting group B streptococcus with reduced penicillin susceptibility.

    PubMed

    Kimura, Kouji; Wachino, Jun-Ichi; Kurokawa, Hiroshi; Suzuki, Satowa; Yamane, Kunikazu; Shibata, Naohiro; Arakawa, Yoshichika

    2009-12-01

    Although group B streptococcus (GBS) has been considered to be uniformly susceptible to beta-lactams, the presence of GBS with reduced penicillin susceptibility (PRGBS) was recently confirmed genetically. We developed a feasible and reliable method for screening PRGBS in clinical microbiology laboratories using a combination of ceftibuten, oxacillin, and ceftizoxime disks.

  11. Serum markers for type II diabetes mellitus

    DOEpatents

    Metz, Thomas O; Qian, Wei-Jun; Jacobs, Jon M; Polpitiya, Ashoka D; Camp, II, David G; Smith, Richard D

    2014-03-18

    A method for identifying persons with increased risk of developing type 2 diabetes mellitus utilizing selected biomarkers described hereafter either alone or in combination. The present invention allows for broad based, reliable, screening of large population bases and provides other advantages, including the formulation of effective strategies for characterizing, archiving, and contrasting data from multiple sample types under varying conditions.

  12. Validation of the Use of Dried Blood Spot (DBS) Method to Assess Vitamin A Status

    PubMed Central

    Fallah, Elham; Peighambardoust, Seyed Hadi

    2012-01-01

    Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne¬cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS) method in screening the deficient populations. The validity of this method for retinol measurement was investigated. Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci¬sion was calculated and compared with those of plasma using F-test. The agreement was eva¬luated using Bland-Altman plot. Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma). A good correlation coefficient (r2=0.78) was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P < 0.01). Paired t-test showed no significant difference between the DBS and retinol methods on a group level. Imprecision of DBS measurement was acceptable, compared to that of the plasma method. The difference be¬tween these two methods was not statistically significant on a group level. Conclusion: Application of DBS standard samples, in which a part of the plasma was replaced with the artificial plasma, was shown to be a reliable calibration mean for retinol measurements in DBS samples. Retinol in dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma. PMID:24688932

  13. Reliability of visual acuity measurements taken with a notebook and a tablet computer in participants who were illiterate to Roman characters.

    PubMed

    Ruamviboonsuk, Paisan; Sudsakorn, Napitchareeya; Somkijrungroj, Thanapong; Engkagul, Chayanee; Tiensuwan, Montip

    2012-03-01

    Electronic measurement of visual acuity (VA) has been proposed and adopted as a method of determining VA scores in clinical research. Characters (optotypes) are displayed on a monitor screen and the examinee selects a match and inputs his choice to another electronic device. Unfortunately, the optotypes, called Sloan letters, in the standard protocol are 10 Roman characters. This limits their practicabilityfor measuring VA of patients who are illiterate to these characters. The authors introduced a method of displaying the Sloan letters one by one on a notebook and all 10 Sloan letters on a tablet computer screen. The former is for testing the patients whereas the latter is for them to input their responses by tapping on a letter that matches the one on the notebook screen. To assess test-retest reliability of VA scores determined with this method. Participants without ocular abnormality were recruited to have their right eyes measured with the same VA measurement method twice, one week apart. Those who were illiterate to Roman characters were enrolled for the aforementioned method for measuring their VA (Tablet group). A 15-inch display notebook computer and a 9-inch display tablet computer (iPad) communicated via a local wireless data network provided by a Wi-Fi router. Those who understood Roman characters were enrolled to have measurements with a 17-inch desktop computer and an infrared wireless keyboard (Keyboard group). Both methods used the same protocols and software for VA measurements. Reliability of VA scores obtained from each group was assessed by the confidence interval (CI) of the difference of the scores from the test and retest. The t test was used to analyze differences in mean VA scores between the test and retest in each group with p < 0.05 determined as statistically significant. There were 49 and 50 participants in the Tablet and Keyboard group respectively. The 95% CI of the difference between the scores from the test and retest in each group was 2 letters. Approximately 95% of participants in each group had an absolute difference of the scores between the test and retest of 7 letters. The mean of VA scores from the first test was significantly different from that of the second test in the Keyboard group (one-letter difference, p = 0.049); there was no significant difference between these scores in the Tablet group (0.1-letter difference, p = 0.86). Tablet computers may be used to assist patients who are illiterate to Roman characters in having their VA measured with the standard electronic protocol. This preliminary study suggested that the proposed method should be useful for reliable measuring VA outcome in multicenter international clinical trials without encountering a language barrier

  14. [Reliability and validity of depression scales of Chinese version: a systematic review].

    PubMed

    Sun, X Y; Li, Y X; Yu, C Q; Li, L M

    2017-01-10

    Objective: Through systematically reviewing the reliability and validity of depression scales of Chinese version in adults in China to evaluate the psychometric properties of depression scales for different groups. Methods: Eligible studies published before 6 May 2016 were retrieved from the following database: CNKI, Wanfang, PubMed and Embase. The HSROC model of the diagnostic test accuracy (DTA) for Meta-analysis was used to calculate the pooled sensitivity and specificity of the PHQ-9. Results: A total of 44 papers evaluating the performance of depression scales were included. Results showed that the reliability and validity of the common depression scales were eligible, including the Beck depression inventory (BDI), the Hamilton depression scale (HAMD), the center epidemiological studies depression scale (CES-D), the patient health questionnaire (PHQ) and the Geriatric depression scale (GDS). The Cronbach' s coefficient of most tools were larger than 0.8, while the test-retest reliability and split-half reliability were larger than 0.7, indicating good internal consistency and stability. The criterion validity, convergent validity, discrimination validity and screening validity were acceptable though different cut-off points were recommended by different studies. The pooled sensitivity of the 11 studies evaluating PHQ-9 was 0.88 (95 %CI : 0.85-0.91) while the pooled specificity was 0.89 (95 %CI : 0.82-0.94), which demonstrated the applicability of PHQ-9 in screening depression. Conclusion: The reliability and validity of different depression scales of Chinese version are acceptable. The characteristics of different tools and study population should be taken into consideration when choosing a specific scale.

  15. NEW FRONTIERS IN DRUGGABILITY

    PubMed Central

    Kozakov, Dima; Hall, David R.; Napoleon, Raeanne L.; Yueh, Christine; Whitty, Adrian; Vajda, Sandor

    2016-01-01

    A powerful early approach to evaluating the druggability of proteins involved determining the hit rate in NMR-based screening of a library of small compounds. Here we show that a computational analog of this method, based on mapping proteins using small molecules as probes, can reliably reproduce druggability results from NMR-based screening, and can provide a more meaningful assessment in cases where the two approaches disagree. We apply the method to a large set of proteins. The results show that, because the method is based on the biophysics of binding rather than on empirical parameterization, meaningful information can be gained about classes of proteins and classes of compounds beyond those resembling validated targets and conventionally druglike ligands. In particular, the method identifies targets that, while not druggable by druglike compounds, may become druggable using compound classes such as macrocycles or other large molecules beyond the rule-of-five limit. PMID:26230724

  16. Screening for depression in clinical practice: reliability and validity of a five-item subset of the CES-Depression.

    PubMed

    Bohannon, Richard W; Maljanian, Rose; Goethe, John

    2003-12-01

    Individuals with chronic disease are not screened routinely for depression. Availability of an abbreviated test with demonstrated reliability and validity might encourage screening so we explored the reliability and validity of a 5-item subset of the 20-item Center for Epidemiological Studies Depression Scale among inner-city outpatients with chronic asthma or diabetes. Most patients were female (73.1%) and Hispanic (61.8%). Acceptable reliability was shown by Cronbach alpha (.76) for the subset of 5 items. Validity was supported by the high correlation of .91 between patients' scores on the 5-item subset and the full 20 items. The 5 items reflected a single factor (eigenvalue = 2.66). Receiver operating characteristic curve analysis identified cut-points for the 5 items that were sensitive (> .84) and specific (> or = .80) in identifying patients classified as depressed by full 20 items. The reduced patient and clinician burden of the subset of 5 items, as well as its desirable psychometric properties, support broader application of this subset as a screening tool for depression.

  17. Screening for Partner Violence Among Family Mediation Clients: Differentiating Types of Abuse.

    PubMed

    Cleak, Helen; Schofield, Margot J; Axelsen, Lauren; Bickerdike, Andrew

    2018-04-01

    Family mediation is mandated in Australia for couples in dispute over separation and parenting as a first step in dispute resolution, except where there is a history of intimate partner violence. However, validation of effective well-differentiated partner violence screening instruments suitable for mediation settings is at an early phase of development. This study contributes to calls for better violence screening instruments in the mediation context to detect a differentiated range of abusive behaviors by examining the reliability and validity of both established scales, and newly developed scales that measured intimate partner violence by partner and by self. The study also aimed to examine relationships between types of abuse, and between gender and types of abuse. A third aim was to examine associations between types of abuse and other relationship indicators such as acrimony and parenting alliance. The data reported here are part of a larger mixed method, naturalistic longitudinal study of clients attending nine family mediation centers in Victoria, Australia. The current analyses on baseline cross-sectional screening data confirmed the reliability of three subscales of the Conflict Tactics Scale (CTS2), and the reliability and validity of three new scales measuring intimidation, controlling and jealous behavior, and financial control. Most clients disclosed a history of at least one type of violence by partner: 95% reported psychological aggression, 72% controlling and jealous behavior, 50% financial control, and 35% physical assault. Higher rates of abuse perpetration were reported by partner versus by self, and gender differences were identified. There were strong associations between certain patterns of psychologically abusive behavior and both acrimony and parenting alliance. The implications for family mediation services and future research are discussed.

  18. The assessment of biases in the acoustic discrimination of individuals

    PubMed Central

    Šálek, Martin

    2017-01-01

    Animal vocalizations contain information about individual identity that could potentially be used for the monitoring of individuals. However, the performance of individual discrimination is subjected to many biases depending on factors such as the amount of identity information, or methods used. These factors need to be taken into account when comparing results of different studies or selecting the most cost-effective solution for a particular species. In this study, we evaluate several biases associated with the discrimination of individuals. On a large sample of little owl male individuals, we assess how discrimination performance changes with methods of call description, an increasing number of individuals, and number of calls per male. Also, we test whether the discrimination performance within the whole population can be reliably estimated from a subsample of individuals in a pre-screening study. Assessment of discrimination performance at the level of the individual and at the level of call led to different conclusions. Hence, studies interested in individual discrimination should optimize methods at the level of individuals. The description of calls by their frequency modulation leads to the best discrimination performance. In agreement with our expectations, discrimination performance decreased with population size. Increasing the number of calls per individual linearly increased the discrimination of individuals (but not the discrimination of calls), likely because it allows distinction between individuals with very similar calls. The available pre-screening index does not allow precise estimation of the population size that could be reliably monitored. Overall, projects applying acoustic monitoring at the individual level in population need to consider limitations regarding the population size that can be reliably monitored and fine-tune their methods according to their needs and limitations. PMID:28486488

  19. Posttraumatic stress disorder in veterans and military personnel: epidemiology, screening, and case recognition.

    PubMed

    Gates, Margaret A; Holowka, Darren W; Vasterling, Jennifer J; Keane, Terence M; Marx, Brian P; Rosen, Raymond C

    2012-11-01

    Posttraumatic stress disorder (PTSD) is a psychiatric disorder that affects 7-8% of the general U.S. population at some point during their lifetime; however, the prevalence is much higher among certain subgroups, including active duty military personnel and veterans. In this article, we review the empirical literature on the epidemiology and screening of PTSD in military and veteran populations, including the availability of sensitive and reliable screening tools. Although estimates vary across studies, evidence suggests that the prevalence of PTSD in deployed U.S. military personnel may be as high as 14-16%. Prior studies have identified trauma characteristics and pre- and posttrauma factors that increase risk of PTSD among veterans and military personnel. This information may help to inform prevention and screening efforts, as screening programs could be targeted to high-risk populations. Large-scale screening efforts have recently been implemented by the U.S. Departments of Defense and Veterans Affairs. Given the prevalence and potential consequences of PTSD among veterans and active duty military personnel, development and continued evaluation of effective screening methods is an important public health need.

  20. Psychometric properties of the SCOFF questionnaire (Chinese version) for screening eating disorders in Hong Kong secondary school students: a cross-sectional study.

    PubMed

    Leung, Sau Fong; Lee, Ka Li; Lee, Sze Man; Leung, Sik Chi; Hung, Wing Sze; Lee, Wai Leng; Leung, Yuen Yee; Li, Man Wai; Tse, Tak Kin; Wong, Hoi Kei; Wong, Yuen Ni

    2009-02-01

    Eating disorders are affecting an increasing number of high school students in Western and Asian countries. The availability of an effective screening tool is crucial for early detection and prompt intervention. The objective of this study was to examine the validity and reliability of the SCOFF questionnaire for screening eating disorders in Hong Kong high school students. This study adopted a cross-sectional design to examine the psychometric properties of the SCOFF questionnaire. A panel of 7 experts and 936 students of a high school participated in the study. The SCOFF questionnaire was translated into Chinese and back-translated into English to ensure the linguistic equivalence. A panel of 7 experts involved in the content validation of the SCOFF questionnaire. The Eating Disorder Examination-Questionnaire (EDE-Q) was used as the "reference standard" to assess its concurrent validity in 936 students of a high school. Its reliability was examined by internal consistency and the test-retest method at a 2-week interval and with 38 students. The SCOFF questionnaire achieved an agreement of 86-100% among the experts for the content relevance. Of 812 students (86.8%) who responded to this study, their SCOFF scores correlated significantly with their global scores on the EDE-Q (r=0.5, P<0.01). Students identified as potentially having eating disorders had significantly higher scores in the EDE-Q than those not identified as such by SCOFF. The SCOFF questionnaire demonstrated moderate test-retest reliability (ICC=0.66) and an acceptable internal consistency reliability (Cronbach's alpha=0.44-0.57) in comparing with previous studies. The SCOFF questionnaire has acceptable psychometric properties in the Chinese culture. It will be useful for detecting potential eating disorders and assisting health promotion activity.

  1. Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

    NASA Technical Reports Server (NTRS)

    Johnson, G. M.

    1976-01-01

    The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

  2. Fluorescence-based assay as a new screening tool for toxic chemicals

    PubMed Central

    Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey

    2016-01-01

    Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients. PMID:27653274

  3. Fluorescence-based assay as a new screening tool for toxic chemicals.

    PubMed

    Moczko, Ewa; Mirkes, Evgeny M; Cáceres, César; Gorban, Alexander N; Piletsky, Sergey

    2016-09-22

    Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.

  4. Fluorescence-based assay as a new screening tool for toxic chemicals

    NASA Astrophysics Data System (ADS)

    Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey

    2016-09-01

    Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.

  5. Development, reliability, and validity testing of Toddler NutriSTEP: a nutrition risk screening questionnaire for children 18-35 months of age.

    PubMed

    Randall Simpson, Janis; Gumbley, Jillian; Whyte, Kylie; Lac, Jane; Morra, Crystal; Rysdale, Lee; Turfryer, Mary; McGibbon, Kim; Beyers, Joanne; Keller, Heather

    2015-09-01

    Nutrition is vital for optimal growth and development of young children. Nutrition risk screening can facilitate early intervention when followed by nutritional assessment and treatment. NutriSTEP (Nutrition Screening Tool for Every Preschooler) is a valid and reliable nutrition risk screening questionnaire for preschoolers (aged 3-5 years). A need was identified for a similar questionnaire for toddlers (aged 18-35 months). The purpose was to develop a reliable and valid Toddler NutriSTEP. Toddler NutriSTEP was developed in 4 phases. Content and face validity were determined with a literature review, parent focus groups (n = 6; 48 participants), and experts (n = 13) (phase A). A draft questionnaire was refined with key intercept interviews of 107 parents/caregivers (phase B). Test-retest reliability (phase C), based on intra-class correlations (ICC), Kappa (κ) statistics, and Wilcoxon tests was assessed with 133 parents/caregivers. Criterion validity (phase D) was assessed using Receiver Operating Characteristic (ROC) curves by comparing scores on the Toddler NutriSTEP to a comprehensive nutritional assessment of 200 toddlers with a registered dietitian (RD). The Toddler NutriSTEP was reliable between 2 administrations (ICC = 0.951, F = 20.53, p < 0.001); most questions had moderate (κ ≥ 0.6) or excellent (κ ≥ 0.8) agreement. Scores on the RD nutrition risk rating and the Toddler NutriSTEP were correlated (r = 0.67, p < 0.000). The area under the ROC curve for moderate and high RD risk ratings were 84.6% and 82.7%, respectively. Cut-points of ≥21 (sensitivity 86%; specificity 61%) (moderate risk) and ≥26 (sensitivity 95%; specificity 63%) (high risk) were determined. The Toddler NutriSTEP questionnaire is both reliable and valid for screening for nutritional risk in toddlers.

  6. The interrater and test-retest reliability of the Home Falls and Accidents Screening Tool (HOME FAST) in Malaysia: Using raters with a range of professional backgrounds.

    PubMed

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy

    2017-06-01

    Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.

  7. Validity of a novel computerized screening test system for mild cognitive impairment.

    PubMed

    Park, Jin-Hyuck; Jung, Minye; Kim, Jongbae; Park, Hae Yean; Kim, Jung-Ran; Park, Ji-Hyuk

    2018-06-20

    ABSTRACTBackground:The mobile screening test system for screening mild cognitive impairment (mSTS-MCI) was developed for clinical use. However, the clinical usefulness of mSTS-MCI to detect elderly with MCI from those who are cognitively healthy has yet to be validated. Moreover, the comparability between this system and traditional screening tests for MCI has not been evaluated. The purpose of this study was to examine the validity and reliability of the mSTS-MCI and confirm the cut-off scores to detect MCI. The data were collected from 107 healthy elderly people and 74 elderly people with MCI. Concurrent validity was examined using the Korean version of Montreal Cognitive Assessment (MoCA-K) as a gold standard test, and test-retest reliability was investigated using 30 of the study participants at four-week intervals. The sensitivity, specificity, positive predictive value, and negative predictive value (NPV) were confirmed through Receiver Operating Characteristic (ROC) analysis, and the cut-off scores for elderly people with MCI were identified. Concurrent validity showed statistically significant correlations between the mSTS-MCI and MoCA-K and test-rests reliability indicated high correlation. As a result of screening predictability, the mSTS-MCI had a higher NPV than the MoCA-K. The mSTS-MCI was identified as a system with a high degree of validity and reliability. In addition, the mSTS-MCI showed high screening predictability, indicating it can be used in the clinical field as a screening test system for mild cognitive impairment.

  8. An Alternative Thiol-Reactive Dye to Analyze Ligand Interactions with the Chemokine Receptor CXCR2 Using a New Thermal Shift Assay Format.

    PubMed

    Bergsdorf, Christian; Fiez-Vandal, Cédric; Sykes, David A; Bernet, Pascal; Aussenac, Sonia; Charlton, Steven J; Schopfer, Ulrich; Ottl, Johannes; Duckely, Myriam

    2016-03-01

    Integral membrane proteins (IMPs) play an important role in many cellular events and are involved in numerous pathological processes. Therefore, understanding the structure and function of IMPs is a crucial prerequisite to enable successful targeting of these proteins with low molecular weight (LMW) ligands early on in the discovery process. To optimize IMP purification/crystallization and to identify/characterize LMW ligand-target interactions, robust, reliable, high-throughput, and sensitive biophysical methods are needed. Here, we describe a differential scanning fluorimetry (DSF) screening method using the thiol-reactive BODIPY FL-cystine dye to monitor thermal unfolding of the G-protein-coupled receptor (GPCR), CXCR2. To validate this method, the seven-transmembrane protein CXCR2 was analyzed with a set of well-characterized antagonists. This study showed that the new DSF assay assessed reliably the stability of CXCR2 in a 384-well format. The analysis of 14 ligands with a potency range over 4 log units demonstrated the detection/characterization of LMW ligands binding to the membrane protein target. Furthermore, DSF results cross-validated with the label-free differential static light scattering (DSLS) thermal denaturation method. These results underline the potential of the BODIPY assay format as a general tool to investigate membrane proteins and their interaction partners. © 2015 Society for Laboratory Automation and Screening.

  9. Docking-based classification models for exploratory toxicology ...

    EPA Pesticide Factsheets

    Background: Exploratory toxicology is a new emerging research area whose ultimate mission is that of protecting human health and environment from risks posed by chemicals. In this regard, the ethical and practical limitation of animal testing has encouraged the promotion of computational methods for the fast screening of huge collections of chemicals available on the market. Results: We derived 24 reliable docking-based classification models able to predict the estrogenic potential of a large collection of chemicals having high quality experimental data, kindly provided by the U.S. Environmental Protection Agency (EPA). The predictive power of our docking-based models was supported by values of AUC, EF1% (EFmax = 7.1), -LR (at SE = 0.75) and +LR (at SE = 0.25) ranging from 0.63 to 0.72, from 2.5 to 6.2, from 0.35 to 0.67 and from 2.05 to 9.84, respectively. In addition, external predictions were successfully made on some representative known estrogenic chemicals. Conclusion: We show how structure-based methods, widely applied to drug discovery programs, can be adapted to meet the conditions of the regulatory context. Importantly, these methods enable one to employ the physicochemical information contained in the X-ray solved biological target and to screen structurally-unrelated chemicals. Shows how structure-based methods, widely applied to drug discovery programs, can be adapted to meet the conditions of the regulatory context. Evaluation of 24 reliable dockin

  10. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia.

    PubMed

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D; Smirnakis, Stelios; Aslanides, Ioannis M

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia.

  11. RADAR: A novel fast-screening method for reading difficulties with special focus on dyslexia

    PubMed Central

    Smyrnakis, Ioannis; Andreadakis, Vassilios; Selimis, Vassilios; Kalaitzakis, Michail; Bachourou, Theodora; Kaloutsakis, Georgios; Kymionis, George D.; Smirnakis, Stelios; Aslanides, Ioannis M.

    2017-01-01

    Dyslexia is a developmental learning disorder of single word reading accuracy and/or fluency, with compelling research directed towards understanding the contributions of the visual system. While dyslexia is not an oculomotor disease, readers with dyslexia have shown different eye movements than typically developing students during text reading. Readers with dyslexia exhibit longer and more frequent fixations, shorter saccade lengths, more backward refixations than typical readers. Furthermore, readers with dyslexia are known to have difficulty in reading long words, lower skipping rate of short words, and high gaze duration on many words. It is an open question whether it is possible to harness these distinctive oculomotor scanning patterns observed during reading in order to develop a screening tool that can reliably identify struggling readers, who may be candidates for dyslexia. Here, we introduce a novel, fast, objective, non-invasive method, named Rapid Assessment of Difficulties and Abnormalities in Reading (RADAR) that screens for features associated with the aberrant visual scanning of reading text seen in dyslexia. Eye tracking parameter measurements that are stable under retest and have high discriminative power, as indicated by their ROC (receiver operating characteristic) curves, were obtained during silent text reading. These parameters were combined to derive a total reading score (TRS) that can reliably separate readers with dyslexia from typical readers. We tested TRS in a group of school-age children ranging from 8.5 to 12.5 years of age. TRS achieved 94.2% correct classification of children tested. Specifically, 35 out of 37 control (specificity 94.6%) and 30 out of 32 readers with dyslexia (sensitivity 93.8%) were classified correctly using RADAR, under a circular validation condition (see section Results/Total Reading Score) where the individual evaluated was not included in the test construction group. In conclusion, RADAR is a novel, automated, fast and reliable way to identify children at high risk of dyslexia that is amenable to large-scale screening. Moreover, analysis of eye movement parameters obtained with RADAR during reading will likely be useful for implementing individualized treatment strategies and for monitoring objectively the success of chosen interventions. We envision that it will be possible to use RADAR as a sensitive, objective, and quantitative first pass screen to identify individuals with reading disorders that manifest with abnormal oculomotor reading strategies, like dyslexia. PMID:28800632

  12. A Rapid Method for Quantifying Viable Mycobacterium avium subsp. paratuberculosis in Cellular Infection Assays

    PubMed Central

    Pooley, Hannah B.; de Silva, Kumudika; Purdie, Auriol C.; Begg, Douglas J.; Whittington, Richard J.

    2016-01-01

    ABSTRACT Determining the viability of bacteria is a key outcome of in vitro cellular infection assays. Currently, this is done by culture, which is problematic for fastidious slow-growing bacteria such as Mycobacterium avium subsp. paratuberculosis, where it can take up to 4 months to confirm growth. This study aimed to identify an assay that can rapidly quantify the number of viable M. avium subsp. paratuberculosis cells in a cellular sample. Three commercially available bacterial viability assays along with a modified liquid culture method coupled with high-throughput quantitative PCR growth detection were assessed. Criteria for assessment included the ability of each assay to differentiate live and dead M. avium subsp. paratuberculosis organisms and their accuracy at low bacterial concentrations. Using the culture-based method, M. avium subsp. paratuberculosis growth was reliably detected and quantified within 2 weeks. There was a strong linear association between the 2-week growth rate and the initial inoculum concentration. The number of viable M. avium subsp. paratuberculosis cells in an unknown sample was quantified based on the growth rate, by using growth standards. In contrast, none of the commercially available viability assays were suitable for use with samples from in vitro cellular infection assays. IMPORTANCE Rapid quantification of the viability of Mycobacterium avium subsp. paratuberculosis in samples from in vitro cellular infection assays is important, as it allows these assays to be carried out on a large scale. In vitro cellular infection assays can function as a preliminary screening tool, for vaccine development or antimicrobial screening, and also to extend findings derived from experimental animal trials. Currently, by using culture, it takes up to 4 months to obtain quantifiable results regarding M. avium subsp. paratuberculosis viability after an in vitro infection assay; however, with the quantitative PCR and liquid culture method developed, reliable results can be obtained at 2 weeks. This method will be important for vaccine and antimicrobial screening work, as it will allow a greater number of candidates to be screened in the same amount of time, which will increase the likelihood that a favorable candidate will be found to be subjected to further testing. PMID:27371585

  13. Screening of antagonistic bacteria for biological control of nursery wilt of black pepper (Piper nigrum).

    PubMed

    Anith, K N; Radhakrishnan, N V; Manomohandas, T P

    2003-01-01

    Bacterial antagonists of Phytophthora capsici were isolated from underground shoot portions of rooted cuttings of black pepper. Initially isolates were screened by dual culture on potato dextrose agar and carrot agar. Further, a screening was done on black pepper shoots for supression of lesion caused by the pathogen. Most of the antagonists showed varying levels of antagonism in the dual culture and the shoot assay. Isolate PN-026, showing the highest suppression of lesion development in the shoot assay was found to be the most efficient antagonist in reducing Phytophthora capsici induced nursery wilt of black pepper. This screening involving the host, pathogen, and the antagonist, performed on black pepper shoot (the planting material for this vegetatively propagated crop), could be used as a rapid and reliable method for the isolation of efficient bacterial antagonists of P. capsici.

  14. Developing an undue influence screening tool for Adult Protective Services.

    PubMed

    Quinn, Mary Joy; Nerenberg, Lisa; Navarro, Adria E; Wilber, Kathleen H

    2017-03-01

    The study purpose was to develop and pilot an undue influence screening tool for California's Adult Protective Services (APS) personnel based on the definition of undue influence enacted into California law January 1, 2014. Methods included four focus groups with APS providers (n = 33), piloting the preliminary tool by APS personnel (n = 15), and interviews with four elder abuse experts and two APS administrators. Social service literature-including existing undue influence models-was reviewed, as were existing screening and assessment tools. Using the information from these various sources, the California Undue Influence Screening Tool (CUIST) was developed. It can be applied to APS cases and potentially adapted for use by other professionals and for use in other states. Implementation of the tool into APS practice, policy, procedures, and training of personnel will depend on the initiative of APS management. Future work will need to address the reliability and validity of CUIST.

  15. Identification of a New Isoindole-2-yl Scaffold as a Qo and Qi Dual Inhibitor of Cytochrome bc 1 Complex: Virtual Screening, Synthesis, and Biochemical Assay.

    PubMed

    Azizian, Homa; Bagherzadeh, Kowsar; Shahbazi, Sophia; Sharifi, Niusha; Amanlou, Massoud

    2017-09-18

    Respiratory chain ubiquinol-cytochrome (cyt) c oxidoreductase (cyt bc 1 or complex III) has been demonstrated as a promising target for numerous antibiotics and fungicide applications. In this study, a virtual screening of NCI diversity database was carried out in order to find novel Qo/Qi cyt bc 1 complex inhibitors. Structure-based virtual screening and molecular docking methodology were employed to further screen compounds with inhibition activity against cyt bc 1 complex after extensive reliability validation protocol with cross-docking method and identification of the best score functions. Subsequently, the application of rational filtering procedure over the target database resulted in the elucidation of a novel class of cyt bc 1 complex potent inhibitors with comparable binding energies and biological activities to those of the standard inhibitor, antimycin.

  16. Validation of the Brazilian Portuguese version of the Premenstrual Symptoms Screening Tool (PSST) and association of PSST scores with health-related quality of life.

    PubMed

    Câmara, Rachel de A; Köhler, Cristiano A; Frey, Benicio N; Hyphantis, Thomas N; Carvalho, André F

    2017-01-01

    To develop and validate a Brazilian Portuguese version of the Premenstrual Symptoms Screening Tool (PSST), a questionnaire used for the screening of premenstrual syndrome (PMS) and of the most severe form of PMS, premenstrual dysphoric disorder (PMDD). The PSST also rates the impact of premenstrual symptoms on daily activities. A consecutive sample of 801 women aged ≥ 18 years completed the study protocol. The internal consistency, test-retest reliability, and content validity of the Brazilian PSST were determined. The independent association of a positive screen for PMS or PMDD and quality of life determined by the World Health Organization Quality of Life instrument-Abbreviated version (WHOQOL-Bref) was also assessed. Of 801 participants, 132 (16.5%) had a positive screening for PMDD. The Brazilian PSST had adequate internal consistency (Cronbach's alpha = 0.91) and test-retest reliability. The PSST also had adequate convergent/discriminant validity, without redundancy. Content validity ratio and content validity index were 0.61 and 0.94 respectively. Finally, a positive screen for PMS/PMDD was associated with worse WHOQOL-Bref scores. These findings suggest that PSST is a reliable and valid instrument to screen for PMS/PMDD in Brazilian women.

  17. Reliability of the Tuck Jump Injury Risk Screening Assessment in Elite Male Youth Soccer Players.

    PubMed

    Read, Paul J; Oliver, Jon L; de Ste Croix, Mark B A; Myer, Gregory D; Lloyd, Rhodri S

    2016-06-01

    Read, PJ, Oliver, JL, de Ste Croix, MBA, Myer, GD, and Lloyd, RS. Reliability of the tuck jump injury risk screening assessment in elite male youth soccer players. J Strength Cond Res 30(6): 1510-1516, 2016-Altered neuromuscular control has been suggested as a mechanism for injury in soccer players. Ligamentous injuries most often occur during dynamic movements, such as decelerations from jump-landing maneuvers where high-risk movement patterns are present. The assessment of kinematic variables during jump-landing tasks as part of a preparticipation screen is useful in the identification of injury risk. An example of a field-based screening tool is the repeated tuck jump assessment. The purpose of this study was to analyze the within-subject variation of the tuck jump screening assessment in elite male youth soccer players. Twenty-five pre-peak height velocity (PHV) and 25 post-PHV elite male youth soccer players from the academy of a professional English soccer club completed the assessment. A test-retest design was used to explore the within-subject intersession reliability. Technique was graded retrospectively against the 10-point criteria set out in the screening protocol using two-dimensional video cameras. The typical error range reported for tuck jump total score (0.90-1.01 in pre-PHV and post-PHV players respectively) was considered acceptable. When each criteria was analyzed individually, kappa coefficient determined that knee valgus was the only criterion to reach substantial agreement across the two test sessions for both groups. The results of this study suggest that although tuck jump total score may be reliably assessed in elite male youth soccer players, caution should be applied in solely interpreting the composite score due to the high within-subject variation in a number of the individual criteria. Knee valgus may be reliably used to screen elite youth male soccer players for this plyometric technique error and for test-retest comparison.

  18. Reliability of Tuberculosis Screening Test in Patients Receiving Tumor Necrosis Factor Antagonist Therapy in a United States Rheumatology Clinic

    DTIC Science & Technology

    2013-05-06

    The purpose of the study was to assess the reliability of latent tuberculosis infection (LTBI) screening in patients being treated with tumor...Candida and/or Tetanus Patient with (+) TST and/or (+) QTB-G and those with CXR finding concerning for LTBI were referred to Infectious Disease for evaluation

  19. Generalizability Theory Reliability of Written Expression Curriculum-Based Measurement in Universal Screening

    ERIC Educational Resources Information Center

    Keller-Margulis, Milena A.; Mercer, Sterett H.; Thomas, Erin L.

    2016-01-01

    The purpose of this study was to examine the reliability of written expression curriculum-based measurement (WE-CBM) in the context of universal screening from a generalizability theory framework. Students in second through fifth grade (n = 145) participated in the study. The sample included 54% female students, 49% White students, 23% African…

  20. A colorimetric assay of 1-aminocyclopropane-1-carboxylate (ACC) based on ninhydrin reaction for rapid screening of bacteria containing ACC deaminase.

    PubMed

    Li, Z; Chang, S; Lin, L; Li, Y; An, Q

    2011-08-01

    1-Aminocyclopropane-1-carboxylate (ACC) deaminase activity is an efficient marker for bacteria to promote plant growth by lowering ethylene levels in plants. We aim to develop a method for rapidly screening bacteria containing ACC deaminase, based on a colorimetric ninhydrin assay of ACC. A reliable colorimetric ninhydrin assay was developed to quantify ACC using heat-resistant polypropylene chimney-top 96-well PCR plates, having the wells evenly heated in boiling water, preventing accidental contamination from boiling water and limiting evaporation. With this method to measure bacterial consumption of ACC, 44 ACC-utilizing bacterial isolates were rapidly screened out from 311 bacterial isolates that were able to grow on minimal media containing ACC as the sole nitrogen source. The 44 ACC-utilizing bacterial isolates showed ACC deaminase activities and belonged to the genus Burkholderia, Pseudomonas or Herbaspirillum. Determination of bacterial ACC consumption by the PCR-plate ninhydrin-ACC assay is a rapid and efficient method for screening bacteria containing ACC deaminase from a large number of bacterial isolates. The PCR-plate ninhydrin-ACC assay extends the utility of the ninhydrin reaction and enables a rapid screening of bacteria containing ACC deaminase from large numbers of bacterial isolates. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  1. Electrochemical Skin Conductance May Be Used to Screen for Diabetic Cardiac Autonomic Neuropathy in a Chinese Population with Diabetes

    PubMed Central

    He, Tianyi; Wang, Chuan; Zuo, Anju; Liu, Pan; Li, Wenjuan

    2017-01-01

    Aims. This study aimed to assess whether the electrochemical skin conductance (ESC) could be used to screen for diabetic cardiac autonomic neuropathy (DCAN) in a Chinese population with diabetes. Methods. We recruited 75 patients with type 2 diabetes mellitus (T2DM) and 45 controls without diabetes. DCAN was diagnosed by the cardiovascular autonomic reflex tests (CARTs) as gold standard. In all subjects ESCs of hands and feet were also detected by SUDOSCAN™ as a new screening method. The efficacy was assessed by receiver operating characteristic (ROC) curve analysis. Results. The ESCs of both hands and feet were significantly lower in T2DM patients with DCAN than those without DCAN (67.33 ± 15.37 versus 78.03 ± 13.73, P = 0.002, and 57.77 ± 20.99 versus 75.03 ± 11.41, P < 0.001). The ROC curve analysis showed the areas under the ROC curve were both 0.75 for ESCs of hands and feet in screening DCAN. And the optimal cut-off values of ESCs, sensitivities, and specificities were 76 μS, 76.7%, and 75.6% for hands and 75 μS, 80.0%, and 60.0% for feet, respectively. Conclusions. ESC measurement is a reliable and feasible method to screen DCAN in the Chinese population with diabetes before further diagnosis with CARTs. PMID:28280746

  2. Challenges and the state of the technology for printed sensor arrays for structural monitoring

    NASA Astrophysics Data System (ADS)

    Joshi, Shiv; Bland, Scott; DeMott, Robert; Anderson, Nickolas; Jursich, Gregory

    2017-04-01

    Printed sensor arrays are attractive for reliable, low-cost, and large-area mapping of structural systems. These sensor arrays can be printed on flexible substrates or directly on monitored structural parts. This technology is sought for continuous or on-demand real-time diagnosis and prognosis of complex structural components. In the past decade, many innovative technologies and functional materials have been explored to develop printed electronics and sensors. For example, an all-printed strain sensor array is a recent example of a low-cost, flexible and light-weight system that provides a reliable method for monitoring the state of aircraft structural parts. Among all-printing techniques, screen and inkjet printing methods are well suited for smaller-scale prototyping and have drawn much interest due to maturity of printing procedures and availability of compatible inks and substrates. Screen printing relies on a mask (screen) to transfer a pattern onto a substrate. Screen printing is widely used because of the high printing speed, large selection of ink/substrate materials, and capability of making complex multilayer devices. The complexity of collecting signals from a large number of sensors over a large area necessitates signal multiplexing electronics that need to be printed on flexible substrate or structure. As a result, these components are subjected to same deformation, temperature and other parameters for which sensor arrays are designed. The characteristics of these electronic components, such as transistors, are affected by deformation and other environmental parameters which can lead to erroneous sensed parameters. The manufacturing and functional challenges of the technology of printed sensor array systems for structural state monitoring are the focus of this presentation. Specific examples of strain sensor arrays will be presented to highlight the technical challenges.

  3. Reliable screening of various foodstuffs with respect to their irradiation status: A comparative study of different analytical techniques

    NASA Astrophysics Data System (ADS)

    Ahn, Jae-Jun; Akram, Kashif; Kwak, Ji-Young; Jeong, Mi-Seon; Kwon, Joong-Ho

    2013-10-01

    Cost-effective and time-efficient analytical techniques are required to screen large food lots in accordance to their irradiation status. Gamma-irradiated (0-10 kGy) cinnamon, red pepper, black pepper, and fresh paprika were investigated using photostimulated luminescence (PSL), direct epifluorescent filter technique/the aerobic plate count (DEFT/APC), and electronic-nose (e-nose) analyses. The screening results were also confirmed with thermoluminescence analysis. PSL analysis discriminated between irradiated (positive, >5000 PCs) and non-irradiated (negative, <700 PCs) cinnamon and red peppers. Black pepper had intermediate results (700-5000 PCs), while paprika had low sensitivity (negative results) upon irradiation. The DEFT/APC technique also showed clear screening results through the changes in microbial profiles, where the best results were found in paprika, followed by red pepper and cinnamon. E-nose analysis showed a dose-dependent discrimination in volatile profiles upon irradiation through principal component analysis. These methods can be used considering their potential applications for the screening analysis of irradiated foods.

  4. “Up Means Good”

    PubMed Central

    Tourangeau, Roger

    2013-01-01

    This paper presents results from six experiments that examine the effect of the position of an item on the screen on the evaluative ratings it receives. The experiments are based on the idea that respondents expect “good” things—those they view positively—to be higher up on the screen than “bad” things. The experiments use items on different topics (Congress and HMOs, a variety of foods, and six physician specialties) and different methods for varying their vertical position on the screen. A meta-analysis of all six experiments demonstrates a small but reliable effect of the item’s screen position on mean ratings of the item; the ratings are significantly more positive when the item appears in a higher position on the screen than when it appears farther down. These results are consistent with the hypothesis that respondents follow the “Up means good” heuristic, using the vertical position of the item as a cue in evaluating it. Respondents seem to rely on heuristics both in interpreting response scales and in forming judgments. PMID:24634546

  5. Targeted Provision of Oral Iron: The Evolution of a Practical Screening Option123

    PubMed Central

    Crowley, Caitlin R.; Solomons, Noel W.; Schümann, Klaus

    2012-01-01

    Universal oral iron supplementation, undertaken according to 1998 WHO guidelines, produced adverse consequences among some children in malaria-endemic areas. Prompted by the Pemba trial, which revealed excessive hospitalizations and deaths, WHO advised that iron supplementation in such regions be accompanied by previous screening for iron deficiency. This agenda, however, poses issues of cost, benefit, acceptability, technical feasibility, and reliability of such screening. The cost of equipment and personnel is balanced against savings from iron supplements spared and treatment for morbidity averted. Costs aside, the most efficacious acceptable screening approach for avoiding hospitalization and deaths must be fielded. Screening before supplementation can be used to assess hematological, iron, and possible inflammatory status to differentiate the source of decreased hemoglobin concentration. Iron deficiency has often been inferred from hematological status markers. The need for extraction of blood, albeit capillary in origin, and high assay costs limit the use of validated methods in screening. Noninvasive methods, i.e., not requiring the extraction of blood, provide the most acceptable and potentially least expensive approach for determining hematological or iron status. Although a noninvasive technique for iron and inflammatory status would be the ideal, it is unattained. Field-friendly, skin-probe hemoglobin devices, derived from instruments for clinical settings, are being developed and tested for eventual rollout in malarial areas. Given a firm grounding for the theoretical requirements needed to advance the screening agenda, evaluation and monitoring of the performance of screening devices can proceed hand in hand. PMID:22797993

  6. A comprehensive review of the psychometric properties of the Drug Abuse Screening Test.

    PubMed

    Yudko, Errol; Lozhkina, Olga; Fouts, Adriana

    2007-03-01

    This article reviews the reliability and the validity of the (10-, 20-, and 28-item) Drug Abuse Screening Test (DAST). The reliability and the validity of the adolescent version of the DAST are also reviewed. An extensive literature review was conducted using the Medline and Psychinfo databases from the years 1982 to 2005. All articles that addressed the reliability and the validity of the DAST were examined. Publications in which the DAST was used as a screening tool but had no data on its psychometric properties were not included. Descriptive information about each version of the test, as well as discussion of the empirical literature that has explored measures of the reliability and the validity of the DAST, has been included. The DAST tended to have moderate to high levels of test-retest, interitem, and item-total reliabilities. The DAST also tended to have moderate to high levels of validity, sensitivity, and specificity. In general, all versions of the DAST yield satisfactory measures of reliability and validity for use as clinical or research tools. Furthermore, these tests are easy to administer and have been used in a variety of populations.

  7. A low density microarray method for the identification of human papillomavirus type 18 variants.

    PubMed

    Meza-Menchaca, Thuluz; Williams, John; Rodríguez-Estrada, Rocío B; García-Bravo, Aracely; Ramos-Ligonio, Ángel; López-Monteon, Aracely; Zepeda, Rossana C

    2013-09-26

    We describe a novel microarray based-method for the screening of oncogenic human papillomavirus 18 (HPV-18) molecular variants. Due to the fact that sequencing methodology may underestimate samples containing more than one variant we designed a specific and sensitive stacking DNA hybridization assay. This technology can be used to discriminate between three possible phylogenetic branches of HPV-18. Probes were attached covalently on glass slides and hybridized with single-stranded DNA targets. Prior to hybridization with the probes, the target strands were pre-annealed with the three auxiliary contiguous oligonucleotides flanking the target sequences. Screening HPV-18 positive cell lines and cervical samples were used to evaluate the performance of this HPV DNA microarray. Our results demonstrate that the HPV-18's variants hybridized specifically to probes, with no detection of unspecific signals. Specific probes successfully reveal detectable point mutations in these variants. The present DNA oligoarray system can be used as a reliable, sensitive and specific method for HPV-18 variant screening. Furthermore, this simple assay allows the use of inexpensive equipment, making it accessible in resource-poor settings.

  8. A Low Density Microarray Method for the Identification of Human Papillomavirus Type 18 Variants

    PubMed Central

    Meza-Menchaca, Thuluz; Williams, John; Rodríguez-Estrada, Rocío B.; García-Bravo, Aracely; Ramos-Ligonio, Ángel; López-Monteon, Aracely; Zepeda, Rossana C.

    2013-01-01

    We describe a novel microarray based-method for the screening of oncogenic human papillomavirus 18 (HPV-18) molecular variants. Due to the fact that sequencing methodology may underestimate samples containing more than one variant we designed a specific and sensitive stacking DNA hybridization assay. This technology can be used to discriminate between three possible phylogenetic branches of HPV-18. Probes were attached covalently on glass slides and hybridized with single-stranded DNA targets. Prior to hybridization with the probes, the target strands were pre-annealed with the three auxiliary contiguous oligonucleotides flanking the target sequences. Screening HPV-18 positive cell lines and cervical samples were used to evaluate the performance of this HPV DNA microarray. Our results demonstrate that the HPV-18's variants hybridized specifically to probes, with no detection of unspecific signals. Specific probes successfully reveal detectable point mutations in these variants. The present DNA oligoarray system can be used as a reliable, sensitive and specific method for HPV-18 variant screening. Furthermore, this simple assay allows the use of inexpensive equipment, making it accessible in resource-poor settings. PMID:24077317

  9. An integrated high resolution mass spectrometric data acquisition method for rapid screening of saponins in Panax notoginseng (Sanqi).

    PubMed

    Lai, Chang-Jiang-Sheng; Tan, Ting; Zeng, Su-Ling; Qi, Lian-Wen; Liu, Xin-Guang; Dong, Xin; Li, Ping; Liu, E-Hu

    2015-05-10

    The aim of this study was to develop a convenient method without pretreatments for nontarget discovery of interested compounds. The segment and exposure strategy, coupled with two mass spectrometer data acquisition methods was firstly proposed for screening the saponins in extract of Panax notoginseng (Sanqi) via high-performance liquid chromatography tandem quadrupole time-of-flight mass spectrometry (HPLC-QTOF/MS). By gradually removing certain major or moderate interference compounds, the developed segment and exposure strategy could significantly improve the detection efficiency for trace compounds. Moreover, the newly developed five-point screening approach based on a modified mass defect filter strategy and the visual isotopic ion technique was verified to be efficient and reliable in picking out the interested precursor ions. In total, 234 ginsenosides including 67 potential new ones were characterized or tentatively identified from the extract of Sanqi. Particularly, some unusual compounds containing the branched glycosyl group or new substituted acyl groups were firstly reported. The proposed integrated strategy held a strong promise for analyses of the complex mixtures. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A screening questionnaire for voice problems after treatment of early glottic cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gogh, Christine D.L. van; Verdonck-de Leeuw, Irma M.; Boon-Kamma, Brigitte A.

    Purpose: After treatment for early glottic cancer, a considerable number of patients end up with voice problems interfering with daily life activities. A 5-item screening questionnaire was designed for detection of voice impairment. The purpose of this study is to assess psychometric properties of this questionnaire in clinical practice. Methods and Materials: The questionnaire was completed by 110 controls without voice complaints and 177 patients after radiotherapy or laser surgery for early glottic cancer. Results: Based on normative data of the controls, a score of 5 or less on at least 1 of the 5 questions was considered to statemore » overall voice impairment. Reliability of the questionnaire proved to be good. Voice impairment was reported in 44% of the patients treated with radiotherapy vs. 29% of the patients treated with endoscopic laser surgery. Conclusions: The questionnaire proved to be a reliable, valid, and feasible method to detect voice impairment in daily life. The questionnaire is easy to fill in, and interpretation is straightforward. It is useful for both radiation oncologists and otorhinolaryngologists in their follow-up of patients treated for early glottic cancer.« less

  11. Consequences of screening in lung cancer: development and dimensionality of a questionnaire.

    PubMed

    Brodersen, John; Thorsen, Hanne; Kreiner, Svend

    2010-08-01

    The objective of this study was to extend the Consequences of Screening (COS) Questionnaire for use in a lung cancer screening by testing for comprehension, content coverage, dimensionality, and reliability. In interviews, the suitability, content coverage, and relevance of the COS were tested on participants in a lung cancer screening program. The results were thematically analyzed to identify the key consequences of abnormal and false-positive screening results. Item Response Theory and Classical Test Theory were used to analyze data. Dimensionality, objectivity, and reliability were established by item analysis, examining the fit between item responses and Rasch models. Eight themes specifically relevant for participants in lung cancer screening results were identified: "self-blame,"focus on symptoms,"stigmatization,"introvert,"harm of smoking,"impulsivity,"empathy," and "regretful of still smoking." Altogether, 26 new items for part I and 16 new items for part II were generated. These themes were confirmed to fit a partial-credit Rasch model measuring different constructs including several of the new items. In conclusion, the reliability and the dimensionality of a condition-specific measure with high content validity for persons having abnormal or false-positive lung cancer screening results have been demonstrated. This new questionnaire called Consequences of Screening in Lung Cancer (COS-LC) covers in two parts the psychosocial experience in lung cancer screening. Part I: "anxiety,"behavior,"dejection,"sleep,"self-blame,"focus on airway symptoms,"stigmatization,"introvert," and "harm of smoking." Part II: "calm/relax,"social network,"existential values,"impulsivity,"empathy," and "regretful of still smoking."

  12. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    PubMed

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. SkinEthic Laboratories, a company devoted to develop and produce in vitro alternative methods to animal use.

    PubMed

    de Brugerolle, Anne

    2007-01-01

    SkinEthic Laboratories is a France-based biotechnology company recognised as the world leader in tissue engineering. SkinEthic is devoted to develop and produce reliable and robust in vitro alternative methods to animal use in cosmetic, chemical and pharmaceutical industries. SkinEthic models provide relevant tools for efficacy and safety screening tests in order to support an integrated decision-making during research and development phases. Some screening tests are referenced and validated as alternatives to animal use (Episkin), others are in the process of validation under ECVAM and OECD guidelines. SkinEthic laboratories provide a unique and joined experience of more than 20 years from Episkin SNC and SkinEthic SA. Their unique cell culture process allows in vitro reconstructed human tissues with well characterized histology, functionality and ultrastructure features to be mass produced. Our product line includes skin models: a reconstructed human epidermis with a collagen layer, Episkin, reconstructed human epidermis without or with melanocytes (with a tanning degree from phototype II to VI) and a reconstructed human epithelium, i.e. cornea, and other mucosa, i.e. oral, gingival, oesophageal and vaginal. Our philosophy is based on 3 main commitments: to support our customers by providing robust and reliable models, to ensure training and education in using validated protocols, allowing a large array of raw materials, active ingredients and finished products in solid, liquid, powder, cream or gel form to be screened, and, to provide a dedicated service to our partners.

  14. Clinical management of HPV-related disease of the lower genital tract.

    PubMed

    Kyrgiou, M; Valasoulis, G; Founta, C; Koliopoulos, G; Karakitsos, P; Nasioutziki, M; Navrozoglou, I; Dalkalitsis, N; Paraskevaidis, E

    2010-09-01

    Cytology remains the mainstay for cervical screening. The need to achieve effective management, limit complications, and preserve reproductive function led to the popularity of local treatment. Although the cure rates for ablative and excisional methods are similar, the excisional method provides a more reliable histopathological diagnosis. Recent evidence revealed increased perinatal morbidity after treatment that appears to be related to the proportion of cervix removed. The human papillomavirus (HPV) DNA test appears to enhance the detection of disease in primary screening, in the triage of minor cytological abnormalities, and in follow-up. Further research on the clinical application of a scoring system is ongoing. The vaccines are now available and appear to be safe, well tolerated, and highly efficacious in HPV naive women. A synergy of vaccination and screening will be required. Treatment for early cervical cancer is increasingly shifting toward more fertility-sparing surgical techniques. Careful selection of patients is essential. © 2010 New York Academy of Sciences.

  15. Contributions of the Computer-Administered Neuropsychological Screen for Mild Cognitive Impairment (CANS-MCI) for the diagnosis of MCI in Brazil.

    PubMed

    Memória, Cláudia M; Yassuda, Mônica S; Nakano, Eduardo Y; Forlenza, Orestes V

    2014-05-07

    ABSTRACT Background: The Computer-Administered Neuropsychological Screen for Mild Cognitive Impairment (CANS-MCI) is a computer-based cognitive screening instrument that involves automated administration and scoring and immediate analyses of test sessions. The objective of this study was to translate and culturally adapt the Brazilian Portuguese version of the CANS-MCI (CANS-MCI-BR) and to evaluate its reliability and validity for the diagnostic screening of MCI and dementia due to Alzheimer's disease. Methods: The test was administered to 97 older adults (mean age 73.41 ± 5.27 years) with at least four years of formal education (mean education 12.23 ± 4.48 years). Participants were classified into three diagnostic groups according to global cognitive status (normal controls, n = 41; MCI, n = 35; AD, n = 21) based on clinical data and formal neuropsychological assessments. Results: The results indicated high internal consistency (Cronbach's α = 0.77) in the total sample. Three-month test-retest reliability correlations were significant and robust (0.875; p < 0.001). A moderate level of concurrent validity was attained relative to the screening test for MCI (MoCA test, r = 0.76, p < 0.001). Confirmatory factor analysis supported the three-factor model of the original test, i.e., memory, language/spatial fluency, and executive function/mental control. Goodness of fit indicators were strong (Bentler Comparative Fit Index = 0.96, Root Mean Square Error of Approximation = 0.09). Receiver operating characteristic curve analyses suggested high sensitivity and specificity (81% and 73% respectively) to screen for possible MCI cases. Conclusions: The CANS-MCI-BR maintains adequate psychometric characteristics that render it suitable to identify elderly adults with probable cognitive impairment to whom a more extensive evaluation by formal neuropsychological tests may be required.

  16. A Multimedia Child Developmental Screening Checklist: Design and Validation

    PubMed Central

    Cheng, Hsin-Yi Kathy; Chen, Li-Ying; Cheng, Chih-Hsiu; Ju, Yan-Ying; Chen, Chia-Ling

    2016-01-01

    Background Identifying disability early in life confers long-term benefits for children. The Taipei City Child Development Screening tool, second version (Taipei II) provides checklists for 13 child age groups from 4 months to 6 years. However, the usability of a text-based screening tool largely depends on the literacy level and logical reasoning ability of the caregivers, as well as language barriers caused by increasing numbers of immigrants. Objective The objectives of this study were to (1) design and develop a Web-based multimedia version of the current Taipei II developmental screening tool, and (2) investigate the measurement equivalence of this multimedia version to the original paper-based version. Methods To develop the multimedia version of Taipei II, a team of experts created illustrations, translations, and dubbing of the original checklists. The developmental screening test was administered to a total of 390 primary caregivers of children aged between 4 months and 6 years. Results Psychometric testing revealed excellent agreement between the paper and multimedia versions of Taipei II. Good to excellent reliabilities were demonstrated for all age groups for both the cross-mode similarity (mode intraclass correlation range 0.85-0.96) and the test-retest reliability (r=.93). Regarding the usability, the mean score was 4.80 (SD 0.03), indicating that users were satisfied with their multimedia website experience. Conclusions The multimedia tool produced essentially equivalent results to the paper-based tool. In addition, it had numerous advantages, such as it can facilitate active participation and promote early screening of target populations. ClinicalTrial Clinicaltrials.gov NCT02359591; https://clinicaltrials.gov/ct2/show/NCT02359591 (Archived by WebCite at http://www.webcitation.org/6l21mmdNn) PMID:27777218

  17. Estimation of gingival crevicular blood glucose level for the screening of diabetes mellitus: A simple yet reliable method.

    PubMed

    Parihar, Sarita; Tripathi, Richik; Parihar, Ajit Vikram; Samadi, Fahad M; Chandra, Akhilesh; Bhavsar, Neeta

    2016-01-01

    This study was designed to assess the reliability of blood glucose level estimation in gingival crevicular blood(GCB) for screening diabetes mellitus. 70 patients were included in study. A randomized, double-blind clinical trial was performed. Among these, 39 patients were diabetic (including 4 patients who were diagnosed during the study) and rest 31 patients were non-diabetic. GCB obtained during routine periodontal examination was analyzed by glucometer to know blood glucose level. The same patient underwent for finger stick blood (FSB) glucose level estimation with glucometer and venous blood (VB) glucose level with standardized laboratory method as per American Diabetes Association Guidelines. 1 All the three blood glucose levels were compared. Periodontal parameters were also recorded including gingival index (GI) and probing pocket depth (PPD). A strong positive correlation ( r ) was observed between glucose levels of GCB with FSB and VB with the values of 0.986 and 0.972 in diabetic group and 0.820 and 0.721 in non-diabetic group. As well, the mean values of GI and PPD were more in diabetic group than non-diabetic group with the statistically significant difference ( p  < 0.005). GCB can be reliably used to measure the blood glucose level as the values were closest to glucose levels estimated by VB. The technique is safe, easy to perform and non-invasive to the patient and can increase the frequency of diagnosing diabetes during routine periodontal therapy.

  18. "Up Means Good": The Effect of Screen Position on Evaluative Ratings in Web Surveys.

    PubMed

    Tourangeau, Roger; Couper, Mick P; Conrad, Frederick G

    2013-01-01

    This paper presents results from six experiments that examine the effect of the position of an item on the screen on the evaluative ratings it receives. The experiments are based on the idea that respondents expect "good" things-those they view positively-to be higher up on the screen than "bad" things. The experiments use items on different topics (Congress and HMOs, a variety of foods, and six physician specialties) and different methods for varying their vertical position on the screen. A meta-analysis of all six experiments demonstrates a small but reliable effect of the item's screen position on mean ratings of the item; the ratings are significantly more positive when the item appears in a higher position on the screen than when it appears farther down. These results are consistent with the hypothesis that respondents follow the "Up means good" heuristic, using the vertical position of the item as a cue in evaluating it. Respondents seem to rely on heuristics both in interpreting response scales and in forming judgments.

  19. The Screening Test for Emotional Problems--Teacher-Report Version (Step-T): Studies of Reliability and Validity

    ERIC Educational Resources Information Center

    Erford, Bradley T.; Butler, Caitlin; Peacock, Elizabeth

    2015-01-01

    The Screening Test for Emotional Problems-Teacher Version (STEP-T) was designed to identify students aged 7-17 years with wide-ranging emotional disturbances. Coefficients alpha and test-retest reliability were adequate for all subscales except Anxiety. The hypothesized five-factor model fit the data very well and external aspects of validity were…

  20. Initial Evidence for the Reliability and Validity of the Student Risk Screening Scale with Elementary Age English Learners

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Richards-Tutor, Catherine; Oakes, Wendy Peia; Connor, Kristin

    2014-01-01

    We report findings of a validation study exploring the Student Risk Screening Scale (SRSS; Drummond, 1994) for use with English learners (ELs) attending a large suburban elementary school. First, we explored the reliability of the SRSS by examining internal consistency, with results indicating adequate internal consistency (0.83). Second, we…

  1. Predicting the need for institutional care shortly after admission to rehabilitation: Rasch analysis and predictive validity of the BRASS Index.

    PubMed

    Panella, L; La Porta, F; Caselli, S; Marchisio, S; Tennant, A

    2012-09-01

    Effective discharge planning is increasingly recognised as a critical component of hospital-based Rehabilitation. The BRASS index is a risk screening tool for identification, shortly after hospital admission, of patients who are at risk of post-discharge problems. To evaluate the internal construct validity and reliability of the Blaylock Risk Assessment Screening Score (BRASS) within the rehabilitation setting. Observational prospective study. Rehabilitation ward of an Italian district hospital. One hundred and four consecutively admitted patients. Using classical psychometric methods and Rasch analysis (RA), the internal construct validity and reliability of the BRASS were examined. Also, external and predictive validity of the Rasch-modified BRASS (RMB) score were determined. Reliability of the original BRASS was low (Cronbach's alpha=0.595) and factor analyses showed that it was clearly multidimensional. A RA, based on a reduced 7-BRASS item set (RMB), satisfied model's expectations. Reliability was 0.777. The RMB scores strongly correlated with the original BRASS (rho=0.952; P<0.000) and with FIM™ admission scores (rho=-0.853; P<0.000). A RMB score of 12 was associated with an increased risk of nursing home admission (RR=2.1, 95%CI=1.7-2.5), whereas a score of 17 was associated to a higher risk of length of stay >28 days (RR=7.6, 95%CI=1.8-31.9). This study demonstrated that the original BRASS was multidimensional and unreliable. However, the RMB holds adequate internal construct validity and is sufficiently reliable as a predictor of discharge problems for group, but not individual use. The application of tools and methods (such as the BRASS Index) developed under the biomedical paradigm in a Physical and Rehabilitation Medicine setting may have limitations. Further research is needed to develop, within the rehabilitation setting, a valid measuring tool of risk of post-discharge problems at the individual level.

  2. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review.

    PubMed

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans; Søgaard, Karen

    2014-10-01

    The aims were to compile a schematic overview of clinical scapular assessment methods and critically appraise the methodological quality of the involved studies. A systematic, computer-assisted literature search using Medline, CINAHL, SportDiscus and EMBASE was performed from inception to October 2013. Reference lists in articles were also screened for publications. From 50 articles, 54 method names were identified and categorized into three groups: (1) Static positioning assessment (n = 19); (2) Semi-dynamic (n = 13); and (3) Dynamic functional assessment (n = 22). Fifteen studies were excluded for evaluation due to no/few clinimetric results, leaving 35 studies for evaluation. Graded according to the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN checklist), the methodological quality in the reliability and validity domains was "fair" (57%) to "poor" (43%), with only one study rated as "good". The reliability domain was most often investigated. Few of the assessment methods in the included studies that had "fair" or "good" measurement property ratings demonstrated acceptable results for both reliability and validity. We found a substantially larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general "fair" to "poor". None were examined for all three domains: (1) reliability; (2) validity; and (3) responsiveness. Observational evaluation systems and assessment of scapular upward rotation seem suitably evidence-based for clinical use. Future studies should test and improve the clinimetric properties, and especially diagnostic accuracy and responsiveness, to increase utility for clinical practice.

  3. Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test.

    PubMed

    Krause, David A; Boyd, Michael S; Hager, Allison N; Smoyer, Eric C; Thompson, Anthony T; Hollman, John H

    2015-02-01

    The squat is a fundamental movement of many athletic and daily activities. Methods to clinically assess the squat maneuver range from simple observation to the use of sophisticated equipment. The purpose of this study was to examine the reliability of Coach's Eye (TechSmith Corp), a 2-dimensional (2D) motion analysis mobile device application (app), for assessing maximal sagittal plane hip, knee, and ankle motion during a functional movement screen deep squat, and to compare range of motion values generated by it to those from a Vicon (Vicon Motion Systems Ltd) 3-dimensional (3D) motion analysis system. Twenty-six healthy subjects performed three functional movement screen deep squats recorded simultaneously by both the app (on an iPad [Apple Inc]) and the 3D motion analysis system. Joint angle data were calculated with Vicon Nexus software (Vicon Motion Systems Ltd). The app video was analyzed frame by frame to determine, and freeze on the screen, the deepest position of the squat. With a capacitive stylus reference lines were then drawn on the iPad screen to determine joint angles. Procedures were repeated with approximately 48 hours between sessions. Test-retest intrarater reliability (ICC3,1) for the app at the hip, knee, and ankle was 0.98, 0.98, and 0.79, respectively. Minimum detectable change was hip 6°, knee 6°, and ankle 7°. Hip joint angles measured with the 2D app exceeded measurements obtained with the 3D motion analysis system by approximately 40°. Differences at the knee and ankle were of lower magnitude, with mean differences of 5° and 3°, respectively. Bland-Altman analysis demonstrated a systematic bias in the hip range-of-motion measurement. No such bias was demonstrated at the knee or ankle. The 2D app demonstrated excellent reliability and appeared to be a responsive means to assess for clinical change, with minimum detectable change values ranging from 6° to 7°. These results also suggest that the 2D app may be used as an alternative to a sophisticated 3D motion analysis system for assessing sagittal plane knee and ankle motion; however, it does not appear to be a comparable alternative for assessing hip motion. 3.

  4. Screening of tyrosinase inhibitors by capillary electrophoresis with immobilized enzyme microreactor and molecular docking.

    PubMed

    Cheng, Mengxia; Chen, Zilin

    2017-02-01

    A new method for screening tyrosinase inhibitors from traditional Chinese medicines (TCMs) was successfully developed by capillary electrophoresis with reliable online immobilized enzyme microreactor (IMER). In addition, molecular docking study has been used for supporting inhibition interaction between enzyme and inhibitors. The IMER of tyrosinase was constructed at the outlet of the capillary by using glutaraldehyde as cross-linker. The parameters including enzyme reaction, separation of the substrate and product, and the performance of immobilized tyrosinase were investigated systematically. Because of using short-end injection procedure, the product and substrate were effectively separated within 2 min. The immobilized tyrosinase could remain 80% active for 30 days at 4°C. The Michaelis-Menten constant of tyrosinase was determined as 1.78 mM. Kojic acid, a known tyrosinase inhibitor, was used as a model compound for the validation of the inhibitors screening method. The half-maximal inhibitory concentration of kojic acid was 5.55 μM. The method was successfully applied for screening tyrosinase inhibitors from 15 compounds of TCM. Four compounds including quercetin, kaempferol, bavachinin, and bakuchiol were found having inhibitory potentials. The results obtained in this work were supported by molecular docking study. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry

    PubMed Central

    Sacco, I.C.N.; Picon, A.P.; Ribeiro, A.P.; Sartor, C.D.; Camargo-Junior, F.; Macedo, D.O.; Mori, E.T.T.; Monte, F.; Yamate, G.Y.; Neves, J.G.; Kondo, V.E.; Aliberti, S.

    2012-01-01

    The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol. PMID:22911379

  6. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry.

    PubMed

    Sacco, I C N; Picon, A P; Ribeiro, A P; Sartor, C D; Camargo-Junior, F; Macedo, D O; Mori, E T T; Monte, F; Yamate, G Y; Neves, J G; Kondo, V E; Aliberti, S

    2012-09-01

    The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.

  7. Parallel production and verification of protein products using a novel high-throughput screening method.

    PubMed

    Tegel, Hanna; Yderland, Louise; Boström, Tove; Eriksson, Cecilia; Ukkonen, Kaisa; Vasala, Antti; Neubauer, Peter; Ottosson, Jenny; Hober, Sophia

    2011-08-01

    Protein production and analysis in a parallel fashion is today applied in laboratories worldwide and there is a great need to improve the techniques and systems used for this purpose. In order to save time and money, a fast and reliable screening method for analysis of protein production and also verification of the protein product is desired. Here, a micro-scale protocol for the parallel production and screening of 96 proteins in plate format is described. Protein capture was achieved using immobilized metal affinity chromatography and the product was verified using matrix-assisted laser desorption ionization time-of-flight MS. In order to obtain sufficiently high cell densities and product yield in the small-volume cultivations, the EnBase® cultivation technology was applied, which enables cultivation in as small volumes as 150 μL. Here, the efficiency of the method is demonstrated by producing 96 human, recombinant proteins, both in micro-scale and using a standard full-scale protocol and comparing the results in regard to both protein identity and sample purity. The results obtained are highly comparable to those acquired through employing standard full-scale purification protocols, thus validating this method as a successful initial screening step before protein production at a larger scale. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Recent Developments and Applications of the MMPBSA Method

    PubMed Central

    Wang, Changhao; Greene, D'Artagnan; Xiao, Li; Qi, Ruxi; Luo, Ray

    2018-01-01

    The Molecular Mechanics Poisson-Boltzmann Surface Area (MMPBSA) approach has been widely applied as an efficient and reliable free energy simulation method to model molecular recognition, such as for protein-ligand binding interactions. In this review, we focus on recent developments and applications of the MMPBSA method. The methodology review covers solvation terms, the entropy term, extensions to membrane proteins and high-speed screening, and new automation toolkits. Recent applications in various important biomedical and chemical fields are also reviewed. We conclude with a few future directions aimed at making MMPBSA a more robust and efficient method. PMID:29367919

  9. Multiplier method may be unreliable to predict the timing of temporary hemiepiphysiodesis for coronal angular deformity.

    PubMed

    Wu, Zhenkai; Ding, Jing; Zhao, Dahang; Zhao, Li; Li, Hai; Liu, Jianlin

    2017-07-10

    The multiplier method was introduced by Paley to calculate the timing for temporary hemiepiphysiodesis. However, this method has not been verified in terms of clinical outcome measure. We aimed to (1) predict the rate of angular correction per year (ACPY) at the various corresponding ages by means of multiplier method and verify the reliability based on the data from the published studies and (2) screen out risk factors for deviation of prediction. A comprehensive search was performed in the following electronic databases: Cochrane, PubMed, and EMBASE™. A total of 22 studies met the inclusion criteria. If the actual value of ACPY from the collected date was located out of the range of the predicted value based on the multiplier method, it was considered as the deviation of prediction (DOP). The associations of patient characteristics with DOP were assessed with the use of univariate logistic regression. Only one article was evaluated as moderate evidence; the remaining articles were evaluated as poor quality. The rate of DOP was 31.82%. In the detailed individual data of included studies, the rate of DOP was 55.44%. The multiplier method is not reliable in predicting the timing for temporary hemiepiphysiodesis, even though it is prone to be more reliable for the younger patients with idiopathic genu coronal deformity.

  10. A review on exudates detection methods for diabetic retinopathy.

    PubMed

    Joshi, Shilpa; Karule, P T

    2018-01-01

    The presence of exudates on the retina is the most characteristic symptom of diabetic retinopathy. As exudates are among early clinical signs of DR, their detection would be an essential asset to the mass screening task and serve as an important step towards automatic grading and monitoring of the disease. Reliable identification and classification of exudates are of inherent interest in an automated diabetic retinopathy screening system. Here we review the numerous early studies that used for automatic exudates detection with the aim of providing decision support in addition to reducing the workload of an ophthalmologist. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. [How to screen for pheochromocytoma, primary aldosteronism and Cushing's syndrome].

    PubMed

    Meyer, Patrick

    2009-01-07

    Pheochromocytoma, primary aldosteronism and Cushing's syndrome are uncommon disorders and are difficult to diagnose because laboratory tests lack validation and specificity. Despite these limitations, practice guidelines are proposed to standardize the screening procedure. The most reliable method to diagnose pheochromocytoma is the measurement of plasmatic and/or urinary metanephrines and normetanephrines depending on the pre-test probability of the disease. The approach for detection of primary aldosteronism is based on the aldosterone-renin ratio under standard conditions. Finally, three tests are available to establish the diagnosis of Cushing's syndrome: 24-h urinary free cortisol excretion, low-dose dexamethasone suppression test and the recent and promising late evening salivary cortisol.

  12. Adaptations of the Saker-Solomons test: simple, reliable colorimetric field assays for chloroquine and its metabolites in urine.

    PubMed

    Mount, D L; Nahlen, B L; Patchen, L C; Churchill, F C

    1989-01-01

    Two field-adapted colorimetric methods for measuring the antimalarial drug chloroquine in urine are described. Both are modifications of the method of Saker and Solomons for screening urine for phencyclidine and other drugs of abuse, using the colour reagent tetrabromophenolphthalein ethyl ester. One method is semiquantitative, detecting the presence of chloroquine (Cq) and its metabolites in urine with a 1 microgram/ml detection limit; it is more sensitive and reliable than the commonly used Dill-Glazko method and is as easy to apply in the field. The second method uses a hand-held, battery-operated filter photometer to quantify Cq and its metabolites with a 2 microgram/ml detection limit and a linear range up to 8 micrograms/ml. The first method was validated in the field using a published quantitative colorimetric method and samples from a malaria study in Nigeria. The second method was validated in the laboratory against high-performance liquid chromatographic results on paired samples from the Nigerian study. Both methods may be used in remote locations where malaria is endemic and no electricity is available.

  13. Screening adolescents for substance use-related high-risk sexual behaviors

    PubMed Central

    Levy, Sharon; Sherritt, Lon; Gabrielli, Joy; Shrier, Lydia A.; Knight, John R.

    2010-01-01

    Background: This analysis was undertaken to determine whether adolescents who screened positive for high-risk substance use with the CRAFFT questions were also more likely to engage in risky sexual behaviors than their peers, and to determine the test-retest reliability of a substance use related sexual risk behaviors inventory. Methods: 12- to 18-year-old clinic patients completed a multi-part questionnaire that included 8 demographic items, the CRAFFT substance use screen, and a 14-item scale assessing sexual behaviors associated with substance use. Participants were invited to return one week later to complete an identical assessment battery. Results: Of the 305 study participants, 49 (16.1%) had a positive CRAFFT screen (score of 2 or greater, indicating high risk for substance abuse/dependence) and 101 (33.9%) reported sexual contact during the past 90 days. After controlling for gender, age, race, and number of parents in household, adolescents with a positive CRAFFT screen had significantly greater odds of having sexual contact after using alcohol or other drugs, of having a sexual partner who used alcohol or other drugs, of having sex without a condom, and of having multiple sexual partners within the past year, compared to their CRAFFT negative peers. The substance use related sexual risk behaviors inventory has acceptable test-retest reliability and the 10 frequency questions have scale-like properties with acceptable internal consistency (standardized Cronbach's Alpha = .79). Conclusion: Clinicians should pay special attention to counseling CRAFFT-positive adolescents regarding use of condoms, and the risks associated with sexual activity with multiple partners, while intoxicated, or with an intoxicated partner. PMID:19837353

  14. Translations of Developmental Screening Instruments: An Evidence Map of Available Research.

    PubMed

    El-Behadli, Ana F; Neger, Emily N; Perrin, Ellen C; Sheldrick, R Christopher

    2015-01-01

    Children whose parents do not speak English experience significant disparities in the identification of developmental delays and disorders; however, little is known about the availability and validity of translations of developmental screeners. The goal was to create a map of the scientific evidence regarding translations of the 9 Academy of Pediatrics-recommended screening instruments into languages other than English. The authors conducted a systematic search of Medline and PsycINFO, references of identified articles, publishers' Web sites, and official manuals. Through evidence mapping, a new methodology supported by AHRQ and the Cochrane Collaboration, the authors documented the extent and distribution of published evidence supporting translations of developmental screeners. Data extraction focused on 3 steps of the translation and validation process: (1) translation methods used, (2) collection of normative data in the target language, and (3) evidence for reliability and validity. The authors identified 63 distinct translations among the 9 screeners, of which 44 had supporting evidence published in peer-reviewed sources. Of the 63 translations, 35 had at least some published evidence regarding translation methods used, 28 involving normative data, and 32 regarding reliability and/or construct validity. One-third of the translations found were of the Denver Developmental Screening Test. Specific methods used varied greatly across screeners, as did the level of detail with which results were reported. Few developmental screeners have been translated into many languages. Evidence map of the authors demonstrates considerable variation in both the amount and the comprehensiveness of information available about translated instruments. Informal guidelines exist for conducting translation of psychometric instruments but not for documentation of this process. The authors propose that uniform guidelines be established for reporting translation research in peer-reviewed journals, similar to those for clinical trials and studies of diagnostic accuracy.

  15. Development of a qualitative, multiplex real-time PCR kit for screening of genetically modified organisms (GMOs).

    PubMed

    Dörries, Hans-Henno; Remus, Ivonne; Grönewald, Astrid; Grönewald, Cordt; Berghof-Jäger, Kornelia

    2010-03-01

    The number of commercially available genetically modified organisms (GMOs) and therefore the diversity of possible target sequences for molecular detection techniques are constantly increasing. As a result, GMO laboratories and the food production industry currently are forced to apply many different methods to reliably test raw material and complex processed food products. Screening methods have become more and more relevant to minimize the analytical effort and to make a preselection for further analysis (e.g., specific identification or quantification of the GMO). A multiplex real-time PCR kit was developed to detect the 35S promoter of the cauliflower mosaic virus, the terminator of the nopaline synthase gene of Agrobacterium tumefaciens, the 35S promoter from the figwort mosaic virus, and the bar gene of the soil bacterium Streptomyces hygroscopicus as the most widely used sequences in GMOs. The kit contains a second assay for the detection of plant-derived DNA to control the quality of the often processed and refined sample material. Additionally, the plant-specific assay comprises a homologous internal amplification control for inhibition control. The determined limits of detection for the five assays were 10 target copies/reaction. No amplification products were observed with DNAs of 26 bacterial species, 25 yeasts, 13 molds, and 41 not genetically modified plants. The specificity of the assays was further demonstrated to be 100% by the specific amplification of DNA derived from reference material from 22 genetically modified crops. The applicability of the kit in routine laboratory use was verified by testing of 50 spiked and unspiked food products. The herein described kit represents a simple and sensitive GMO screening method for the reliable detection of multiple GMO-specific target sequences in a multiplex real-time PCR reaction.

  16. Effect of Surge Current Testing on Reliability of Solid Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2008-01-01

    Tantalum capacitors manufactured per military specifications are established reliability components and have less than 0.001% of failures per 1000 hours for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. To reduce this risk, further development of a screening and qualification system with special attention to the possible deficiencies in the existing procedures is necessary. The purpose of this work is evaluation of the effect of surge current stress testing on reliability of the parts at both steady-state and multiple surge current stress conditions. In order to reveal possible degradation and precipitate more failures, various part types were tested and stressed in the range of voltage and temperature conditions exceeding the specified limits. A model to estimate the probability of post-surge current testing-screening failures and measures to improve the effectiveness of the screening process has been suggested.

  17. Automation in visual inspection tasks: X-ray luggage screening supported by a system of direct, indirect or adaptable cueing with low and high system reliability.

    PubMed

    Chavaillaz, Alain; Schwaninger, Adrian; Michel, Stefan; Sauer, Juergen

    2018-05-25

    The present study evaluated three automation modes for improving performance in an X-ray luggage screening task. 140 participants were asked to detect the presence of prohibited items in X-ray images of cabin luggage. Twenty participants conducted this task without automatic support (control group), whereas the others worked with either indirect cues (system indicated the target presence without specifying its location), or direct cues (system pointed out the exact target location) or adaptable automation (participants could freely choose between no cue, direct and indirect cues). Furthermore, automatic support reliability was manipulated (low vs. high). The results showed a clear advantage for direct cues regarding detection performance and response time. No benefits were observed for adaptable automation. Finally, high automation reliability led to better performance and higher operator trust. The findings overall confirmed that automatic support systems for luggage screening should be designed such that they provide direct, highly reliable cues.

  18. Quality of survey reporting in nephrology journals: a methodologic review.

    PubMed

    Li, Alvin Ho-Ting; Thomas, Sonia M; Farag, Alexandra; Duffett, Mark; Garg, Amit X; Naylor, Kyla L

    2014-12-05

    Survey research is an important research method used to determine individuals' attitudes, knowledge, and behaviors; however, as with other research methods, inadequate reporting threatens the validity of results. This study aimed to describe the quality of reporting of surveys published between 2001 and 2011 in the field of nephrology. The top nephrology journals were systematically reviewed (2001-2011: American Journal of Kidney Diseases, Nephrology Dialysis Transplantation, and Kidney International; 2006-2011: Clinical Journal of the American Society of Nephrology) for studies whose primary objective was to collect and report survey results. Included were nephrology journals with a heavy focus on clinical research and high impact factors. All titles and abstracts were screened in duplicate. Surveys were excluded if they were part of a multimethod study, evaluated only psychometric characteristics, or used semi-structured interviews. Information was collected on survey and respondent characteristics, questionnaire development (e.g., pilot testing), psychometric characteristics (e.g., validity and reliability), survey methods used to optimize response rate (e.g., system of multiple contacts), and response rate. After a screening of 19,970 citations, 216 full-text articles were reviewed and 102 surveys were included. Approximately 85% of studies reported a response rate. Almost half of studies (46%) discussed how they developed their questionnaire and only a quarter of studies (28%) mentioned the validity or reliability of the questionnaire. The only characteristic that improved over the years was the proportion of articles reporting missing data (2001-2004: 46.4%; 2005-2008: 61.9%; and 2009-2011: 84.8%; respectively) (P<0.01). The quality of survey reporting in nephrology journals remains suboptimal. In particular, reporting of the validity and reliability of the questionnaire must be improved. Guidelines to improve survey reporting and increase transparency are clearly needed. Copyright © 2014 by the American Society of Nephrology.

  19. Fast Computation and Assessment Methods in Power System Analysis

    NASA Astrophysics Data System (ADS)

    Nagata, Masaki

    Power system analysis is essential for efficient and reliable power system operation and control. Recently, online security assessment system has become of importance, as more efficient use of power networks is eagerly required. In this article, fast power system analysis techniques such as contingency screening, parallel processing and intelligent systems application are briefly surveyed from the view point of their application to online dynamic security assessment.

  20. The intensive care delirium screening checklist: translation and reliability testing in a Swedish ICU.

    PubMed

    Neziraj, M; Sarac Kart, N; Samuelson, Karin

    2011-08-01

    The view of delirium has changed considerably over the last decade, and delirium is now a very topical issue within the intensive care unit (ICU) setting. Delirium has proved to be common in critically ill patients and is manifested as acute changes in mental status with reduced cognitive ability, incoherent thought patterns, impaired consciousness, agitation and acute confusion. In order to be able to prevent, identify and alleviate problems related to delirium it is important that validated instruments for delirium screening are implemented and evaluated. The aim of this study was to translate the Intensive Care Delirium Screening Checklist (ICDSC) into Swedish and test the inter-rater reliability in a Swedish general ICU setting. The study was carried out during 2009 in a general Swedish ICU. A translation of the scale from English into Swedish was made, including back-translation, critical review and pilot testing. A total of 49 paired ratings were carried out using the Swedish version of the ICDSC scale. The inter-rater reliability was tested using weighted kappa (κ) statistics (linear weighting). The ICDSC scale was successfully translated into Swedish and the inter-rater reliability testing of the Swedish version resulted in a weighted k value of 0.92. The result of this study indicates that the Swedish version of the ICDSC scale has a very good inter-rater reliability. The high inter-rater reliability and the ease of administration make the ICDSC scale applicable for delirium screening in a Swedish ICU setting. © 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  1. Additional Evidence for the Reliability and Validity of the Student Risk Screening Scale at the High School Level: A Replication and Extension

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Oakes, Wendy P.; Ennis, Robin Parks; Cox, Meredith Lucille; Schatschneider, Christopher; Lambert, Warren

    2013-01-01

    This study reports findings from a validation study of the Student Risk Screening Scale for use with 9th- through 12th-grade students (N = 1854) attending a rural fringe school. Results indicated high internal consistency, test-retest stability, and inter-rater reliability. Predictive validity was established across two academic years, with Spring…

  2. Adolescent Suicide Risk Screening: The Effect of Communication about Type of Follow-Up on Adolescents’ Screening Responses

    PubMed Central

    King, Cheryl A.; Hill, Ryan M.; Wynne, Henry A.; Cunningham, Rebecca M.

    2013-01-01

    Objective This experimental study examined the effect of communication about type of screening follow-up (in-person follow-up versus no in-person follow-up) on adolescents’ responses to a self-report suicide risk screen. Method Participants were 245 adolescents (131 girls, 114 boys; ages 13 to 17; 80% White, 21.6% Black; 9.8% American Indian; 2.9% Asian), seeking medical emergency services. They were randomized to a screening follow-up condition. Screening measures assessed primary risk factors for suicidal behavior, including suicidal thoughts, depressive symptoms, alcohol use, and aggressive/delinquent behavior. Results There was no main effect of follow-up condition on adolescents’ screening scores; however, significant interactions between follow-up condition and public assistance status were evident. Adolescents whose families received public assistance were less likely to report aggressive-delinquent behavior if assigned to In-Person Follow-Up. Adolescents whose families did not receive public assistance reported significantly higher levels of suicidal ideation if assigned to In-Person Follow-Up. Conclusions Findings suggest that response biases impact some adolescents’ responses to suicide risk screenings. Because national policy strongly recommends suicide risk screening in emergency settings, and because screening scores are used to make critical decisions regarding risk management and treatment recommendations, findings indicate the importance of improving the reliability and validity of suicide risk screening for adolescents. PMID:22540534

  3. Genetic and epigenetic markers in colorectal cancer screening: recent advances.

    PubMed

    Singh, Manish Pratap; Rai, Sandhya; Suyal, Shradha; Singh, Sunil Kumar; Singh, Nand Kumar; Agarwal, Akash; Srivastava, Sameer

    2017-07-01

    Colorectal cancer (CRC) is a heterogenous disease which develops from benign intraepithelial lesions known as adenomas to malignant carcinomas. Acquired alterations in Wnt signaling, TGFβ, MAPK pathway genes and clonal propagation of altered cells are responsible for this transformation. Detection of adenomas or early stage cancer in asymptomatic patients and better prognostic and predictive markers is important for improving the clinical management of CRC. Area covered: In this review, the authors have evaluated the potential of genetic and epigenetic alterations as markers for early detection, prognosis and therapeutic predictive potential in the context of CRC. We have discussed molecular heterogeneity present in CRC and its correlation to prognosis and response to therapy. Expert commentary: Molecular marker based CRC screening methods still fail to gain trust of clinicians. Invasive screening methods, molecular heterogeneity, chemoresistance and low quality test samples are some key challenges which need to be addressed in the present context. New sequencing technologies and integrated omics data analysis of individual or population cohort results in GWAS. MPE studies following a GWAS could be future line of research to establish accurate correlations between CRC and its risk factors. This strategy would identify most reliable biomarkers for CRC screening and management.

  4. A first approach to a neuropsychological screening tool using eye-tracking for bedside cognitive testing based on the Edinburgh Cognitive and Behavioural ALS Screen.

    PubMed

    Keller, Jürgen; Krimly, Amon; Bauer, Lisa; Schulenburg, Sarah; Böhm, Sarah; Aho-Özhan, Helena E A; Uttner, Ingo; Gorges, Martin; Kassubek, Jan; Pinkhardt, Elmar H; Abrahams, Sharon; Ludolph, Albert C; Lulé, Dorothée

    2017-08-01

    Reliable assessment of cognitive functions is a challenging task in amyotrophic lateral sclerosis (ALS) patients unable to speak and write. We therefore present an eye-tracking based neuropsychological screening tool based on the Edinburgh Cognitive and Behavioural ALS Screen (ECAS), a standard screening tool for cognitive deficits in ALS. In total, 46 ALS patients and 50 healthy controls matched for age, gender and education were tested with an oculomotor based and a standard paper-and-pencil version of the ECAS. Significant correlation between both versions was observed for ALS patients and healthy controls in the ECAS total score and in all of its ALS-specific domains (all r > 0.3; all p < 0.05). The eye-tracking version of the ECAS reliably distinguished between ALS patients and healthy controls in the ECAS total score (p < 0.05). Also, cognitively impaired and non-impaired patients could be reliably distinguished with a specificity of 95%. This study provides first evidence that the eye-tracking based ECAS version is a promising approach for assessing cognitive deficits in ALS patients who are unable to speak or write.

  5. Quantifying the Performance of P-Type Transparent Conducting Oxides by Experimental Methods

    PubMed Central

    Fleischer, Karsten; Norton, Emma; Mullarkey, Daragh; Caffrey, David; Shvets, Igor V.

    2017-01-01

    Screening for potential new materials with experimental and theoretical methods has led to the discovery of many promising candidate materials for p-type transparent conducting oxides. It is difficult to reliably assess a good p-type transparent conducting oxide (TCO) from limited information available at an early experimental stage. In this paper we discuss the influence of sample thickness on simple transmission measurements and how the sample thickness can skew the commonly used figure of merit of TCOs and their estimated band gap. We discuss this using copper-deficient CuCrO2 as an example, as it was already shown to be a good p-type TCO grown at low temperatures. We outline a modified figure of merit reducing thickness-dependent errors, as well as how modern ab initio screening methods can be used to augment experimental methods to assess new materials for potential applications as p-type TCOs, p-channel transparent thin film transistors, and selective contacts in solar cells. PMID:28862695

  6. Role Playing for Improving Women’s Knowledge of Breast Cancer Screening and Performance of Breast Self-Examination

    PubMed

    Savabi-Esfahani, Mitra; Taleghani, Fariba; Noroozi, Mahnaz; Tabatabaeian, Maryam

    2017-09-27

    Background: To enhance knowledge and performance of screening as a strategy to control breast cancer, use of effective teaching methods is necessary. The objective of this study was to determine the effect of role-playing on knowledge of breast cancer screening and performance of breast self-examination (BSE). Methods: A quasi experimental design was used. Women enrolled in community cultural centers (n=314) were randomly divided into two educational groups: role playing (intervention) and lecture (control). Data were collected using a structured questionnaire before and after intervention. Reliability of the questionnaire was determined as 0.80 by Cronbach’s alpha. The women were followed up regarding performance of BSE one month later. Results: Of the 314 women, 113 (36%) and 132 (42%) had low and medium levels of knowledge, respectively. More than a third (38.2%) reported that TV and radio were the most important information sources for breast cancer and screening. There were significant differences between mean scores of knowledge before and after the intervention in both groups, but change was greater with role playing (31.3±1.9 as compared to 23.5±1.3) (P=0.001). After a month of educational intervention, 75.7% and 69.8% of those in role playing and control groups had undergone BSE. Conclusion: It appears that application of a role playing method by providers improves women’s knowledge and behavior with respect to breast cancer screening. Creative Commons Attribution License

  7. Development and Validation of a P-35S, T-nos, T-35S and P-FMV Tetraplex Real-time PCR Screening Method to Detect Regulatory Genes of Genetically Modified Organisms in Food.

    PubMed

    Eugster, Albert; Murmann, Petra; Kaenzig, Andre; Breitenmoser, Alda

    2014-10-01

    In routine analysis screening methods based on real-time PCR (polymerase chain reaction) are most commonly used for the detection of genetically modified (GM) plant material in food and feed. Screening tests are based on sequences frequently used for GM development, allowing the detection of a large number of GMOs (genetically modified organisms). Here, we describe the development and validation of a tetraplex real-time PCR screening assay comprising detection systems for the regulatory genes Cauliflower Mosaic Virus 35S promoter, Agrobacterium tumefaciens nos terminator, Cauliflower Mosaic Virus 35S terminator and Figwort Mosaic Virus 34S promoter. Three of the four primer and probe combinations have already been published elsewhere, whereas primers and probe for the 35S terminator have been developed in-house. Adjustment of primer and probe concentrations revealed a high PCR sensitivity with insignificant physical cross-talk between the four detection channels. The sensitivity of each PCR-system is sufficient to detect a GMO concentration as low as 0.05% of the containing respective element. The specificity of the described tetraplex is high when tested on DNA from GM maize, soy, rapeseed and tomato. We also demonstrate the robustness of the system by inter-laboratory tests. In conclusion, this method provides a sensitive and reliable screening procedure for the detection of the most frequently used regulatory elements present in GM crops either authorised or unauthorised for food.

  8. Rapid and Accurate Behavioral Health Diagnostic Screening: Initial Validation Study of a Web-Based, Self-Report Tool (the SAGE-SR)

    PubMed Central

    Purcell, Susan E; Rhea, Karen; Maier, Philip; First, Michael; Zweede, Lisa; Sinisterra, Manuela; Nunn, M Brad; Austin, Marie-Paule; Brodey, Inger S

    2018-01-01

    Background The Structured Clinical Interview for DSM (SCID) is considered the gold standard assessment for accurate, reliable psychiatric diagnoses; however, because of its length, complexity, and training required, the SCID is rarely used outside of research. Objective This paper aims to describe the development and initial validation of a Web-based, self-report screening instrument (the Screening Assessment for Guiding Evaluation-Self-Report, SAGE-SR) based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) and the SCID-5-Clinician Version (CV) intended to make accurate, broad-based behavioral health diagnostic screening more accessible within clinical care. Methods First, study staff drafted approximately 1200 self-report items representing individual granular symptoms in the diagnostic criteria for the 8 primary SCID-CV modules. An expert panel iteratively reviewed, critiqued, and revised items. The resulting items were iteratively administered and revised through 3 rounds of cognitive interviewing with community mental health center participants. In the first 2 rounds, the SCID was also administered to participants to directly compare their Likert self-report and SCID responses. A second expert panel evaluated the final pool of items from cognitive interviewing and criteria in the DSM-5 to construct the SAGE-SR, a computerized adaptive instrument that uses branching logic from a screener section to administer appropriate follow-up questions to refine the differential diagnoses. The SAGE-SR was administered to healthy controls and outpatient mental health clinic clients to assess test duration and test-retest reliability. Cutoff scores for screening into follow-up diagnostic sections and criteria for inclusion of diagnoses in the differential diagnosis were evaluated. Results The expert panel reduced the initial 1200 test items to 664 items that panel members agreed collectively represented the SCID items from the 8 targeted modules and DSM criteria for the covered diagnoses. These 664 items were iteratively submitted to 3 rounds of cognitive interviewing with 50 community mental health center participants; the expert panel reviewed session summaries and agreed on a final set of 661 clear and concise self-report items representing the desired criteria in the DSM-5. The SAGE-SR constructed from this item pool took an average of 14 min to complete in a nonclinical sample versus 24 min in a clinical sample. Responses to individual items can be combined to generate DSM criteria endorsements and differential diagnoses, as well as provide indices of individual symptom severity. Preliminary measures of test-retest reliability in a small, nonclinical sample were promising, with good to excellent reliability for screener items in 11 of 13 diagnostic screening modules (intraclass correlation coefficient [ICC] or kappa coefficients ranging from .60 to .90), with mania achieving fair test-retest reliability (ICC=.50) and other substance use endorsed too infrequently for analysis. Conclusions The SAGE-SR is a computerized adaptive self-report instrument designed to provide rigorous differential diagnostic information to clinicians. PMID:29572204

  9. An Evaluation of Healthcare Information on the Internet: The Case of Colorectal Cancer Prevention

    PubMed Central

    Chen, Chia-Ching; Yamada, Tetsuji; Smith, John

    2014-01-01

    Health information, provided through the Internet, has recently received attention from consumers and healthcare providers as an efficient method of motivating people to get screened for colorectal cancer (CRC). In this study, the primary purpose was to investigate the extent to which consumers were better educated about CRC screening information because of the information available on the Internet. Another purpose was to identify how better-informed consumers, with reliable and trustworthy health information, were enabled to make sound decisions regarding CRC screening. The data used in this study was taken from the 2003 Health Information National Trends Survey. People aged 55 and older were classified based on their compliance with recommended CRC screening. The study applied the PRECEDE-PROCEED model to evaluate the effects of health information taken from the Internet regarding CRC screening. The credibility and reliance of cancer related information on the Internet was significantly associated with patient compliance to be screened for CRC. Experience and knowledge of Internet use had a significant impact on the utilization of CRC screening. This analysis suggests that the design and publishing websites concerning CRC should emphasize credibility and reliance. Websites providing information about CRC must also contain the most current information so that people are able to make educated decisions about CRC screening. PMID:24424284

  10. [The Basel Screening Instrument for Psychosis (BSIP): development, structure, reliability and validity].

    PubMed

    Riecher-Rössler, A; Aston, J; Ventura, J; Merlo, M; Borgwardt, S; Gschwandtner, U; Stieglitz, R-D

    2008-04-01

    Early detection of psychosis is of growing clinical importance. So far there is, however, no screening instrument for detecting individuals with beginning psychosis in the atypical early stages of the disease with sufficient validity. We have therefore developed the Basel Screening Instrument for Psychosis (BSIP) and tested its feasibility, interrater-reliability and validity. Aim of this paper is to describe the development and structure of the instrument, as well as to report the results of the studies on reliability and validity. The instrument was developed based on a comprehensive search of literature on the most important risk factors and early signs of schizophrenic psychoses. The interraterreliability study was conducted on 24 psychiatric cases. Validity was tested based on 206 individuals referred to our early detection clinic from 3/1/2000 until 2/28/2003. We identified seven categories of relevance for early detection of psychosis and used them to construct a semistructured interview. Interrater-reliability for high risk individuals was high (Kappa .87). Predictive validity was comparable to other, more comprehensive instruments: 16 (32 %) of 50 individuals classified as being at risk for psychosis by the BSIP have in fact developed frank psychosis within an follow-up period of two to five years. The BSIP is the first screening instrument for the early detection of psychosis which has been validated based on transition to psychosis. The BSIP is easy to use by experienced psychiatrists and has a very good interrater-reliability and predictive validity.

  11. Pulse Oximetry and Auscultation for Congenital Heart Disease Detection.

    PubMed

    Hu, Xiao-Jing; Ma, Xiao-Jing; Zhao, Qu-Ming; Yan, Wei-Li; Ge, Xiao-Ling; Jia, Bing; Liu, Fang; Wu, Lin; Ye, Ming; Liang, Xue-Cun; Zhang, Jing; Gao, Yan; Zhai, Xiao-Wen; Huang, Guo-Ying

    2017-10-01

    Pulse oximetry (POX) has been confirmed as a specific screening modality for critical congenital heart disease (CCHD), with moderate sensitivity. However, POX is not able to detect most serious and critical cardiac lesions (major congenital heart disease [CHD]) without hypoxemia. In this study, we investigated the accuracy and feasibility of the addition of cardiac auscultation to POX as a screening method for asymptomatic major CHD. A multicenter prospective observational screening study was conducted at 15 hospitals in Shanghai between July 1, 2012, and December 31, 2014. Newborns with either an abnormal POX or cardiac auscultation were defined as screen positive. All screen-positive newborns underwent further echocardiography. False-negative results were identified by clinical follow-up, parents' feedback, and telephone review. We assessed the accuracy of POX plus cardiac auscultation for the detection of major CHD. CHD screening was completed in all 15 hospitals, with a screening rate of 94.0% to 99.8%. In total, 167 190 consecutive asymptomatic newborn infants were screened, of which 203 had major CHD (44 critical and 159 serious). The sensitivity of POX plus cardiac auscultation was 95.5% (95% confidence interval 84.9%-98.7%) for CCHD and 92.1% (95% confidence interval 87.7%-95.1%) for major CHD. The false-positive rate was 1.2% for detecting CCHD and 1.1% for detecting major CHD. In our current study, we show that using POX plus cardiac auscultation significantly improved the detection rate of major CHD in the early neonatal stage, with high sensitivity and a reasonable false-positive rate. It provides strong evidence and a reliable method for neonatal CHD screening. Copyright © 2017 by the American Academy of Pediatrics.

  12. Skin colour assessment of replanted fingers in digital images and its reliability for the incorporation of images in nursing progress notes.

    PubMed

    Terashima, Taiko; Yoshimura, Sadako

    2018-03-01

    To determine whether nurses can accurately assess the skin colour of replanted fingers displayed as digital images on a computer screen. Colour measurement and clinical diagnostic methods for medical digital images have been studied, but reproducing skin colour on a computer screen remains difficult. The inter-rater reliability of skin colour assessment scores was evaluated. In May 2014, 21 nurses who worked on a trauma ward in Japan participated in testing. Six digital images with different skin colours were used. Colours were scored from both digital images and direct patient's observation. The score from a digital image was defined as the test score, and its difference from the direct assessment score as the difference score. Intraclass correlation coefficients were calculated. Nurses' opinions were classified and summarised. The intraclass correlation coefficients for the test scores were fair. Although the intraclass correlation coefficients for the difference scores were poor, they improved to good when three images that might have contributed to poor reliability were excluded. Most nurses stated that it is difficult to assess skin colour in digital images; they did not think it could be a substitute for direct visual assessment. However, most nurses were in favour of including images in nursing progress notes. Although the inter-rater reliability was fairly high, the reliability of colour reproduction in digital images as indicated by the difference scores was poor. Nevertheless, nurses expect the incorporation of digital images in nursing progress notes to be useful. This gap between the reliability of digital colour reproduction and nurses' expectations towards it must be addressed. High inter-rater reliability for digital images in nursing progress notes was not observed. Assessments of future improvements in colour reproduction technologies are required. Further digitisation and visualisation of nursing records might pose challenges. © 2017 John Wiley & Sons Ltd.

  13. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    PubMed

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  14. Reliability and Validity of a Two-Question Alcohol Screen in the Pediatric Emergency Department.

    PubMed

    Spirito, Anthony; Bromberg, Julie R; Casper, T Charles; Chun, Thomas H; Mello, Michael J; Dean, J Michael; Linakis, James G

    2016-12-01

    A multisite study was conducted to determine the psychometric properties of the National Institute of Alcohol Abuse and Alcoholism (NIAAA) 2-question alcohol screen within pediatric emergency departments (PEDs). Participants (N = 4838) included 12- to 17-year-old subjects treated in 1 of the 16 participating PEDs across the United States. A criterion assessment battery (including the NIAAA 2-question alcohol screen and other measures of alcohol, drug use, and risk behaviors) was self-administered on a tablet computer. A subsample (n = 186) was re-administered the NIAAA 2-question screen 1 week later to assess test-retest reliability. Moderate to good test-retest reliability was demonstrated. A classification of moderate risk or higher on the screen had the best combined sensitivity and specificity for determining a diagnosis of alcohol use disorder (AUD) for all students. Any past year drinking among middle school students increased the odds of a diagnosis of an AUD according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition criteria, whereas the optimal cutoff for high school ages was ≥3 drinking days in the past year. The optimal cutoff for drinking days determining a positive Alcohol Use Disorders Identification Test score among middle school subjects was ≥1 drinking day, whereas the optimal cutoff for high school subjects was ≥2 drinking days. The NIAAA 2-question screen is a brief, valid approach for alcohol screening in PEDs. A positive screen suggests that referral for further evaluation is indicated to determine if an adolescent has an AUD. Copyright © 2016 by the American Academy of Pediatrics.

  15. PubMed Central

    Scarponi, L.; Pedrali, S.; Pizzorni, N.; Pinotti, C.; Foieni, F.; Zuccotti, G.; Schindler, A.

    2017-01-01

    SUMMARY The large majority of the available dysphagia screening tools has been developed for the stroke population. Only few screening tools are suitable for heterogeneous groups of patients admitted to a subacute care unit. The Royal Brisbane and Women's Hospital (RBWH) dysphagia screening tool is a nurse-administered, evidence-based swallow screening tool for generic acute hospital use that demonstrates excellent sensitivity and specificity. No Italian version of this tool is available to date. The aim of this study was to determine the reliability and screening accuracy of the Italian version of the RBWH (I-RBWH) dysphagia screening tool. A total of 105 patients consecutively admitted to a subacute care unit were enrolled. Using the I-RBWH tool, each patient was evaluated twice by trained nurses and once by a speech and language pathologist (SLP) blind to nurses' scores. The SLP also performed standardised clinical assessment of swallowing using the Mann assessment of swallowing ability (MASA). During the first and the second administration of the I-RBWH by nurses, 28 and 27 patients, respectively, were considered at risk of dysphagia, and 27 were considered at risk after SLP assessment. Intra- and inter-rater reliability was satisfactory. Comparison between nurse I-RBWH scores and MASA examination demonstrated a sensitivity and specificity of the I-RBWH dysphagia screening tool up to 93% and 96%, respectively; the positive and negative predictive values were 90% and 97%, respectively. Thus, the current findings support the reliability and accuracy of the I-RBWH tool for dysphagia screening of patients in subacute settings. Its application in clinical practice is recommended. PMID:28374867

  16. RELIABILITY OF THE TUCK JUMP INJURY RISK SCREENING ASSESSMENT IN ELITE MALE YOUTH SOCCER PLAYERS

    PubMed Central

    READ, PAUL; OLIVER, JON L.; DE STE CROIX, MARK B.A.; MYER, GREGORY D.; LLOYD, RHODRI S.

    2015-01-01

    Altered neuromuscular control has been suggested as a mechanism for injury in soccer players. Ligamentous injuries most often occur during dynamic movements, such as decelerations from jump-landing maneuvers where high risk movement patterns are present. The assessment of kinematic variables during jump-landing tasks as part of a pre-participation screen is useful in the identification of injury risk. An example of a field-based screening tool is the repeated tuck jump assessment. The purpose of this study was to analyze the within-subject variation of the tuck jump screening assessment in elite male youth soccer players. 25 pre and 25 post-peak height velocity (PHV) elite male youth soccer players from the academy of a professional English soccer club completed the assessment. A test, re-test design was used to explore the within-subject inter-session reliability. Technique was graded retrospectively against the 10-point criteria set out in the screening protocol using two-dimensional video cameras. The typical error range reported for tuck jump total score (0.90 – 1.01 in pre and post-PHV players respectively) was considered acceptable. When each criteria was analyzed individually, Kappa coefficient determined that knee valgus was the only criterion to reach substantial agreement across the two test sessions for both groups. The results of this study suggest that although tuck jump total score may be reliably assessed in elite male youth soccer players, caution should be applied in solely interpreting the composite score due to the high within-subject variation in a number of the individual criteria. Knee valgus may be reliably used to screen elite youth male soccer players for this plyometric technique error and for test, re-test comparison. PMID:26562715

  17. Evaluating concentration estimation errors in ELISA microarray experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daly, Don S.; White, Amanda M.; Varnum, Susan M.

    Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to predict a protein concentration in a sample. Deploying ELISA in a microarray format permits simultaneous prediction of the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Evaluating prediction error is critical to interpreting biological significance and improving the ELISA microarray process. Evaluating prediction error must be automated to realize a reliable high-throughput ELISA microarray system. Methods: In this paper, we present a statistical method based on propagation of error to evaluate prediction errors in the ELISA microarray process. Althoughmore » propagation of error is central to this method, it is effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization and statistical diagnostics when evaluating ELISA microarray prediction errors. We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of prediction errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error.« less

  18. Performance of an Abbreviated Version of the Lubben Social Network Scale among Three European Community-Dwelling Older Adult Populations

    ERIC Educational Resources Information Center

    Lubben, James; Blozik, Eva; Gillmann, Gerhard; Iliffe, Steve; von Renteln-Kruse, Wolfgang; Beck, John C.; Stuck, Andreas E.

    2006-01-01

    Purpose: There is a need for valid and reliable short scales that can be used to assess social networks and social supports and to screen for social isolation in older persons. Design and Methods: The present study is a cross-national and cross-cultural evaluation of the performance of an abbreviated version of the Lubben Social Network Scale…

  19. Automated image-based phenotypic analysis in zebrafish embryos

    PubMed Central

    Vogt, Andreas; Cholewinski, Andrzej; Shen, Xiaoqiang; Nelson, Scott; Lazo, John S.; Tsang, Michael; Hukriede, Neil A.

    2009-01-01

    Presently, the zebrafish is the only vertebrate model compatible with contemporary paradigms of drug discovery. Zebrafish embryos are amenable to automation necessary for high-throughput chemical screens, and optical transparency makes them potentially suited for image-based screening. However, the lack of tools for automated analysis of complex images presents an obstacle to utilizing the zebrafish as a high-throughput screening model. We have developed an automated system for imaging and analyzing zebrafish embryos in multi-well plates regardless of embryo orientation and without user intervention. Images of fluorescent embryos were acquired on a high-content reader and analyzed using an artificial intelligence-based image analysis method termed Cognition Network Technology (CNT). CNT reliably detected transgenic fluorescent embryos (Tg(fli1:EGFP)y1) arrayed in 96-well plates and quantified intersegmental blood vessel development in embryos treated with small molecule inhibitors of anigiogenesis. The results demonstrate it is feasible to adapt image-based high-content screening methodology to measure complex whole organism phenotypes. PMID:19235725

  20. Confirmatory factor analysis of the Chinese Breast Cancer Screening Beliefs Questionnaire.

    PubMed

    Kwok, Cannas; Fethney, Judith; White, Kate

    2012-01-01

    Chinese women have been consistently reported as having low breast cancer screening practices. The Chinese Breast Cancer Screening Beliefs Questionnaire (CBCSB) was designed to assess Chinese Australian women's beliefs, knowledge, and attitudes toward breast cancer and screening practices. The objectives of the study were to confirm the factor structure of the CBCSB with a new, larger sample of immigrant Chinese Australian women and to report its clinical validity. A convenience sample of 785 Chinese Australian women was recruited from Chinese community organizations and shopping malls. Cronbach α was used to assess internal consistency reliability, and Amos v18 was used for confirmatory factor analysis. Clinical validity was assessed through linear regression using SPSS v18. The 3-factor structure of the CBCSB was confirmed, although the model required respecification to arrive at a suitable model fit as measured by the goodness-of-fit index (0.98), adjusted goodness-of-fit index (0.97), normed fit index (0.95), and root mean square error of approximation (0.031). Internal consistency reliability coefficients were satisfactory (>.6). Women who engaged in all 3 types of screening had more proactive attitudes to health checkups and perceived less barriers to mammographic screening. The CBCSB is a valid and reliable tool for assessing Chinese women's beliefs, knowledge, and attitudes about breast cancer and breast cancer screening practices. The CBCSB can be used for providing practicing nurses with insights into the provision of culturally sensitive breast health education.

  1. Psychometric Properties of Brief Screening Tests for Alcohol Use Disorders during Pregnancy in Argentina.

    PubMed

    López, Mariana Beatriz; Lichtenberger, Aldana; Conde, Karina; Cremonte, Mariana

    2017-07-01

    Background  Considering the physical, mental and behavioral problems related to fetal alcohol exposure, prenatal clinical guides suggest a brief evaluation of alcohol consumption during pregnancy to detect alcohol intake and to adjust interventions, if required. Even if any alcohol use should be considered risky during pregnancy, identifying women with alcohol use disorders is important because they could need a more specific intervention than simple advice to abstain. Most screening tests have been developed and validated in male populations and focused on the long-term consequences of heavy alcohol use, so they might be inappropriate to assess consumption in pregnant women. Objective  To analyze the internal reliability and validity of the alcohol screening instruments Alcohol Use Disorders Identification Test (AUDIT), Alcohol Use Disorders Identification Test - Consumption (AUDIT-C), Tolerance, Worried, Eye-Opener, Amnesia and Cut-Down (TWEAK), Rapid Alcohol Problems Screen - Quantity Frequency (RAPS-QF) and Tolerance, Annoyed, Cut-Down and Eye-Opener (T-ACE) to identify alcohol use disorders in pregnant women. Methods  A total of 641 puerperal women were personally interviewed during the 48 hours after delivery. The receiver operating characteristics (ROC) curves and the sensitivity and specificity of each instrument using different cut-off points were analyzed. Results  All instruments showed areas under the ROC curves above 0.80. Larger areas were found for the TWEAK and the AUDIT. The TWEAK, the T-ACE and the AUDIT-C showed higher sensitivity, while the AUDIT and the RAPS-QF showed higher specificity. Reliability (internal consistency) was low for all instruments, improving when optimal cut-off points were used, especially for the AUDIT, the AUDIT-C and the RAPS-QF. Conclusions  In other cultural contexts, studies have concluded that T-ACE and TWEAK are the best instruments to assess pregnant women. In contrast, our results evidenced the low reliability of those instruments and a better performance of the AUDIT in this population. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  2. Liquid chromatography incorporating ultraviolet and electrochemical analyses for dual detection of zeranol and zearalenone metabolites in mouldy grains.

    PubMed

    Hsieh, Han-Yun; Shyu, Ching-Lin; Liao, Chen-Wei; Lee, Ren-Jye; Lee, Maw-Rong; Vickroy, Thomas W; Chou, Chi-Chung

    2012-04-01

    Zeranol (Z) is a semi-synthetic mycotoxin that is used in some countries as a growth-promoting agent in livestock. In view of the known oestrogenic actions by Z and certain Z analogues, significant concerns exist with regard to the presence of Z residues in human foods and the potential for untoward effects, including carcinogenicity within the reproductive system. In order to confirm that foods are free from harmful Z residues, regulators need a quick and reliable analytical method that can be used for routine confirmation of Z-positive samples identified by enzyme-linked immunosorbent assay (ELISA) screening. In this study the authors have developed and validated a simple and rapid high-performance liquid chromatography method incorporating ultraviolet (UV) absorbance (wavelength 274 nm) and electrochemical (EC) dual-mode detection for simultaneous determination of Z-related mycotoxins produced from mouldy grain matrices, including rice, soybean and corn flakes. Recoveries for all analytes were around 80% and the limits of detection ranged from 10 to 25 ng mL(-1) for UV and from 50 to 90 ng mL(-1) for EC detection with good accuracy and reproducibility. Differential profiles and occurrence rates of Z, β-zearalenol, β-zearalanol and α-zearalenol in naturally moulded grain matrices were observed, indicating different metabolite patterns and possibly grain-specific effects of mycotoxin exposure for humans and animals. The strength of this dual detection method lies in its selectivity characterised by a carbon screen-printed electrode such that aflatoxin interference is precluded. The combined dual detection technique affords quick and reliable semi-confirmative and quantitative information on multiple types of Z analogues in mouldy grains without the necessity of using expensive mass spectrometry. The method is considered a superior supplement to ELISA, which only screens total Z immunoreactivity. Copyright © 2011 Society of Chemical Industry.

  3. Robot-Powered Reliability Testing at NREL's ESIF Video Text Version |

    Science.gov Websites

    Video Text Version Robot-Powered Reliability Testing at NREL's ESIF Video Text Version Below is the text version for the Robot-Powered Reliability Testing at NREL's ESIF video. [Text on screen] Robot-Powered

  4. Recent research progress with phospholipase C from Bacillus cereus.

    PubMed

    Lyu, Yan; Ye, Lidan; Xu, Jun; Yang, Xiaohong; Chen, Weiwei; Yu, Hongwei

    2016-01-01

    Phospholipase C (PLC) catalyzes the hydrolysis of phospholipids to produce phosphate monoesters and diacylglycerol. It has many applications in the enzymatic degumming of plant oils. PLC Bc , a bacterial PLC from Bacillus cereus, is an optimal choice for this activity in terms of its wide substrate spectrum, high activity, and approved safety. Unfortunately, its large-scale production and reliable high-throughput screening of PLC Bc remain challenging. Herein, we summarize the research progress regarding PLC Bc with emphasis on the screening methods, expression systems, catalytic mechanisms and inhibitor of PLC Bc . This review hopefully will inspire new achievements in related areas, to promote the sustainable development of PLC Bc and its application.

  5. Risk Assessment for CPAP Nonadherence in Adults with Newly-diagnosed Obstructive Sleep Apnea: Preliminary Testing of the Index for Nonadherence to PAP (I-NAP)

    PubMed Central

    Sawyer, Amy M.; King, Tonya S.; Hanlon, Alexandra; Richards, Kathy C.; Sweer, Leon; Rizzo, Albert; Weaver, Terri E.

    2014-01-01

    Purpose Identification of risk for CPAP nonadherence prior to home treatment is an opportunity to deliver targeted, adherence interventions. Study objectives included (1) test a risk screening questionnaire to prospectively identify CPAP nonadherence risk among adults with newly-diagnosed OSA; (2) reduce the questionnaire to a minimum item set that effectively identifies 1-month CPAP nonadherence; and (3) examine the diagnostic utility of the screening index. Methods A prospective, longitudinal study at two clinical sleep centers in the U.S. included adults with newly diagnosed OSA (n=97; AHI ≥ 5 events/hr) by polysomnogram (PSG) consecutively recruited to participate. After baseline participant and OSA characteristics were collected, a risk screening questionnaire was administered immediately following CPAP titration polysomnogram. One-month objective CPAP use was collected. Results Predominantly white (87%) males (55%) and females (45%) with obesity (BMI 38.3 kg/m2; SD 9.3) and severe OSA (AHI 36.8; SD 19.7) were included. One-month CPAP use was 4.25hrs/night (SD 2.35). Nineteen questionnaire items (I-NAP) reliably identified nonadherers defined at <4hr/night CPAP use (Wald X2[8] =34.67, p<0.0001) with ROC AUC 0.83 (95% CI 0.74-0.91). Optimal score cut-point for the INAP screening questionnaire were determined to maximize sensitivity (87%) while maintaining specificity >60% (63%). Conclusion A risk screening questionnaire employed immediately after titration PSG may reliably identify CPAP nonadherers and permit the delivery of targeted interventions to prevent or reduce nonadherence. This novel approach may enhance cost-effectiveness of care and permit appropriate allocation of resources for CPAP adherence. PMID:24595715

  6. Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. II: Confirmatory analysis.

    PubMed

    Badoud, F; Grata, E; Perrenoud, L; Saugy, M; Rudaz, S; Veuthey, J-L

    2010-06-18

    For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. Surrogate endpoints for cancer screening trials: general principles and an illustration using the UK Flexible Sigmoidoscopy Screening Trial.

    PubMed

    Cuzick, Jack; Cafferty, Fay H; Edwards, Robert; Møller, Henrik; Duffy, Stephen W

    2007-01-01

    Cancer screening is aimed primarily at reducing deaths. Thus, site-specific cancer mortality is the appropriate endpoint for evaluating screening interventions. However, it is also the most demanding endpoint, requiring follow-up and a large numbers of patients order to have adequate power. Therefore, it is highly desirable to have surrogate endpoints that can reliably predict mortality reductions many years earlier. We here review a range of surrogate markers in terms of their potential advantages and pitfalls, and argue that a measure which weights incident cancers according to their predicted mortality has many advantages over other measures and should be used more routinely. Application to the UK Flexible Sigmoidoscopy Screening Trial data suggests that predicted colorectal cancer mortality, based on stage-specific incidence, is a more powerful endpoint than actual mortality and could advance the analysis time by about three years. Total colorectal cancer incidence as a surrogate endpoint provides little advance in the analysis time over actual mortality. The approach requires reliable prognostic data, (e.g. stage), for both the study cohort and a representative sample of the whole population. The routine collection of such data should be a priority for cancer registries. Surrogate endpoints should not replace a long-term analysis based directly on mortality, but can provide reliable early indicators which can be useful both for monitoring ongoing screening programmes and for making policy decisions.

  8. Behavioral Screening for Toxicology | Science Inventory | US ...

    EPA Pesticide Factsheets

    Screening for behavioral toxicity, or neurotoxicity, has been in use for decades; however, only in the past 20 years has this become a standard practice in toxicology. Current screening batteries, such as the functional observational battery (FOB), are derived from protocols used in pharmacology, toxicology, and psychology. Although there is a range of protocols in use today, all focus on detailed observations and specific tests of reflexes and responses. Several neurological functions are typically assessed, including autonomic, neuromuscular, and sensory, as well as levels of activity and excitability. The tests have been shown to be valid in detecting expected effects of known neurotoxicants, and reliable and reproducible whn compared across laboratories. Regardless of the specific protocol used, proper conduct and statistical analyses of the data are critical. Interpretation is based on the information from individual end points as well as the profile, or pattern, of effects observed. As long as continual refinements are made, behavioral screening methods will continue to be important tools with which to protect human health in the future.autonomic function; behavior; behavioral phenotypes; behavioral toxicity; excitability; functional observational battery ; motor activity; mouse; neuromuscular function; positive controls; rat; screening battery ; sensory function Screening for behavioral toxicity, or neurotoxicity, has been in use for decades; how

  9. Hypertrophic Cardiomyopathy in Youth Athletes

    PubMed Central

    Fox, J. Christian; Lahham, Shadi; Maldonado, Graciela; Klaus, Suzi; Aish, Bassil; Sylwanowicz, Lauren V.; Yanuck, Justin; Wilson, Sean P.; Shieh, Mason; Anderson, Craig L.; English, Carter; Mayer, Ryan; Mohan, Uthara R.

    2018-01-01

    Objectives Hypertrophic cardiomyopathy (HCM) is a life-threatening genetic cardiovascular disease that often goes undetected in young athletes. Neither history nor physical examination are reliable to identify those at risk. The objective of this study is to determine whether minimally trained medical student volunteers can use ultrasound to screen for HCM. Methods This was a prospective enrollment of young athletes performed at 12 area high schools and three area colleges, between May 2012 and August 2013. All participants underwent point-of-care ultrasound performed screening for HCM by trained medical students and reviewed by a pediatric cardiologist. An interventricular septum to left ventricular posterior wall ratio greater than 1.25 was considered to be abnormal (positive screen). Results A total of 2332 participants were enrolled. There were 137 (5.8%) with a positive screening for HCM, of which 7 (5.1%) were confirmed to have HCM by a pediatric cardiologist. In a small cohort with positive screen for HCM, there was a 100% sensitivity (95% confidence interval, 59.04 to 100%) and 4.86% (95% confidence interval, 1.98 to 9.76%) positive predictive value of for having HCM. Conclusions Volunteer medical students, using point-of-care ultrasound, were able to effectively screen for HCM in young athletes. PMID:28258593

  10. High resolution melting curve analysis targeting the HBB gene mutational hot-spot offers a reliable screening approach for all common as well as most of the rare beta-globin gene mutations in Bangladesh.

    PubMed

    Islam, Md Tarikul; Sarkar, Suprovath Kumar; Sultana, Nusrat; Begum, Mst Noorjahan; Bhuyan, Golam Sarower; Talukder, Shezote; Muraduzzaman, A K M; Alauddin, Md; Islam, Mohammad Sazzadul; Biswas, Pritha Promita; Biswas, Aparna; Qadri, Syeda Kashfi; Shirin, Tahmina; Banu, Bilquis; Sadya, Salma; Hussain, Manzoor; Sarwardi, Golam; Khan, Waqar Ahmed; Mannan, Mohammad Abdul; Shekhar, Hossain Uddin; Chowdhury, Emran Kabir; Sajib, Abu Ashfaqur; Akhteruzzaman, Sharif; Qadri, Syed Saleheen; Qadri, Firdausi; Mannoor, Kaiissar

    2018-01-02

    Bangladesh lies in the global thalassemia belt, which has a defined mutational hot-spot in the beta-globin gene. The high carrier frequencies of beta-thalassemia trait and hemoglobin E-trait in Bangladesh necessitate a reliable DNA-based carrier screening approach that could supplement the use of hematological and electrophoretic indices to overcome the barriers of carrier screening. With this view in mind, the study aimed to establish a high resolution melting (HRM) curve-based rapid and reliable mutation screening method targeting the mutational hot-spot of South Asian and Southeast Asian countries that encompasses exon-1 (c.1 - c.92), intron-1 (c.92 + 1 - c.92 + 130) and a portion of exon-2 (c.93 - c.217) of the HBB gene which harbors more than 95% of mutant alleles responsible for beta-thalassemia in Bangladesh. Our HRM approach could successfully differentiate ten beta-globin gene mutations, namely c.79G > A, c.92 + 5G > C, c.126_129delCTTT, c.27_28insG, c.46delT, c.47G > A, c.92G > C, c.92 + 130G > C, c.126delC and c.135delC in heterozygous states from the wild type alleles, implying the significance of the approach for carrier screening as the first three of these mutations account for ~85% of total mutant alleles in Bangladesh. Moreover, different combinations of compound heterozygous mutations were found to generate melt curves that were distinct from the wild type alleles and from one another. Based on the findings, sixteen reference samples were run in parallel to 41 unknown specimens to perform direct genotyping of the beta-thalassemia specimens using HRM. The HRM-based genotyping of the unknown specimens showed 100% consistency with the sequencing result. Targeting the mutational hot-spot, the HRM approach could be successfully applied for screening of beta-thalassemia carriers in Bangladesh as well as in other countries of South Asia and Southeast Asia. The approach could be a useful supplement of hematological and electrophortic indices in order to avoid false positive and false negative results.

  11. Studying Regional Wave Source Time Functions Using the Empirical Green's Function Method: Application to Central Asia

    NASA Astrophysics Data System (ADS)

    Xie, J.; Schaff, D. P.; Chen, Y.; Schult, F.

    2013-12-01

    Reliably estimated source time functions (STFs) from high-frequency regional waveforms, such as Lg, Pn and Pg, provide important input for seismic source studies, explosion detection and discrimination, and minimization of parameter trade-off in attenuation studies. We have searched for candidate pairs of larger and small earthquakes in and around China that share the same focal mechanism but significantly differ in magnitudes, so that the empirical Green's function (EGF) method can be applied to study the STFs of the larger events. We conducted about a million deconvolutions using waveforms from 925 earthquakes, and screened the deconvolved traces to exclude those that are from event pairs that involved different mechanisms. Only 2,700 traces passed this screening and could be further analyzed using the EGF method. We have developed a series of codes for speeding up the final EGF analysis by implementing automations and user-graphic interface procedures. The codes have been fully tested with a subset of screened data and we are currently applying them to all the screened data. We will present a large number of deconvolved STFs retrieved using various phases (Lg, Pn, Sn and Pg and coda) with information on any directivities, any possible dependence of pulse durations on the wave types, on scaling relations for the pulse durations and event sizes, and on the estimated source static stress drops.

  12. New multiplex PCR methods for rapid screening of genetically modified organisms in foods

    PubMed Central

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products. PMID:26257724

  13. New multiplex PCR methods for rapid screening of genetically modified organisms in foods.

    PubMed

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products.

  14. Determination of Ochratoxin A in Rye and Rye-Based Products by Fluorescence Polarization Immunoassay

    PubMed Central

    Lippolis, Vincenzo; Porricelli, Anna C. R.; Cortese, Marina; Zanardi, Sandro; Pascale, Michelangelo

    2017-01-01

    A rapid fluorescence polarization immunoassay (FPIA) was optimized and validated for the determination of ochratoxin A (OTA) in rye and rye crispbread. Samples were extracted with a mixture of acetonitrile/water (60:40, v/v) and purified by SPE-aminopropyl column clean-up before performing the FPIA. Overall mean recoveries were 86 and 95% for spiked rye and rye crispbread with relative standard deviations lower than 6%. Limits of detection (LOD) of the optimized FPIA was 0.6 μg/kg for rye and rye crispbread, respectively. Good correlations (r > 0.977) were observed between OTA contents in contaminated samples obtained by FPIA and high-performance liquid chromatography (HPLC) with immunoaffinity cleanup used as reference method. Furthermore, single laboratory validation and small-scale collaborative trials were carried out for the determination of OTA in rye according to Regulation 519/2014/EU laying down procedures for the validation of screening methods. The precision profile of the method, cut-off level and rate of false suspect results confirm the satisfactory analytical performances of assay as a screening method. These findings show that the optimized FPIA is suitable for high-throughput screening, and permits reliable quantitative determination of OTA in rye and rye crispbread at levels that fall below the EU regulatory limits. PMID:28954398

  15. A Coulomb-Like Off-Shell T-Matrix with the Correct Coulomb Phase Shift

    NASA Astrophysics Data System (ADS)

    Oryu, Shinsho; Watanabe, Takashi; Hiratsuka, Yasuhisa; Togawa, Yoshio

    2017-03-01

    We confirm the reliability of the well-known Coulomb renormalization method (CRM). It is found that the CRM is only available for a very-long-range screened Coulomb potential (SCP). However, such an SCP calculation in momentum space is considerably difficult because of the cancelation of significant digits. In contrast to the CRM, we propose a new method by using an on-shell equivalent SCP and the rest term. The two-potential theory with r-space is introduced, which defines fully the off-shell Coulomb amplitude.

  16. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients.

    PubMed

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte; Warming, Susan

    2017-12-01

    Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted due to acute illness, we aimed to determine the interrater reliability of the V-VST in this clinical setting. Reporting in this study is in accordance with proposed guidelines for the reporting of reliability and agreement studies (GRRAS). In three Danish hospitals (CRD-BFH, CRD-GH, NDR-H) 11 skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who administrated the test in an order based on randomization, blinded to each other's results. Agreement, Kappa values, weighed Kappa values and Kappa adjusted for bias and prevalence are reported. The interrater reliability of V-VST as screening test for OD in patients admitted to geriatric or medical wards was substantial with an overall Kappa value of 0.77 (95% CI 0.65-0.89) however interrater reliability varied among hospitals ranging from 0.37 (95% CI -0.01 to 0.41) to 0.85 (95% CI 0.75-1.00). Interrater reliability of the accompanying recommendations of volume and viscosity was moderate with a weighted kappa value of 0.55 (95% CI 0.37-0.73) for viscosity and 0.53 (95% CI 0.36-0.7) for volume. The overall prevalence of OD was 34.5%, ranging from 8% to 53.6% across hospitals. The prevalence and bias adjusted Kappa value (PABAK) was 0.76 (range 0.6-0.85). Mean time to perform the test was 13.1 min (SD 6.924). The V-VST seems to be a moderately reliable screening tool for detecting OD among medical and geriatric patients. However, the recommendations of volume and viscosity add limited clinical value to the test. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  17. Ultrasound semi-automated measurement of fetal nuchal translucency thickness based on principal direction estimation

    NASA Astrophysics Data System (ADS)

    Yoon, Heechul; Lee, Hyuntaek; Jung, Haekyung; Lee, Mi-Young; Won, Hye-Sung

    2015-03-01

    The objective of the paper is to introduce a novel method for nuchal translucency (NT) boundary detection and thickness measurement, which is one of the most significant markers in the early screening of chromosomal defects, namely Down syndrome. To improve the reliability and reproducibility of NT measurements, several automated methods have been introduced. However, the performance of their methods degrades when NT borders are tilted due to varying fetal movements. Therefore, we propose a principal direction estimation based NT measurement method to provide reliable and consistent performance regardless of both fetal positions and NT directions. At first, Radon Transform and cost function are used to estimate the principal direction of NT borders. Then, on the estimated angle bin, i.e., the main direction of NT, gradient based features are employed to find initial NT lines which are beginning points of the active contour fitting method to find real NT borders. Finally, the maximum thickness is measured from distances between the upper and lower border of NT by searching along to the orthogonal lines of main NT direction. To evaluate the performance, 89 of in vivo fetal images were collected and the ground-truth database was measured by clinical experts. Quantitative results using intraclass correlation coefficients and difference analysis verify that the proposed method can improve the reliability and reproducibility in the measurement of maximum NT thickness.

  18. Reliability and validity of Champion's Health Belief Model Scale for breast cancer screening among Malaysian women.

    PubMed

    Parsa, P; Kandiah, M; Mohd Nasir, M T; Hejar, A R; Nor Afiah, M Z

    2008-11-01

    Breast cancer is the leading cause of cancer deaths in Malaysian women, and the use of breast self-examination (BSE), clinical breast examination (CBE) and mammography remain low in Malaysia. Therefore, there is a need to develop a valid and reliable tool to measure the beliefs that influence breast cancer screening practices. The Champion's Health Belief Model Scale (CHBMS) is a valid and reliable tool to measure beliefs about breast cancer and screening methods in the Western culture. The purpose of this study was to translate the use of CHBMS into the Malaysian context and validate the scale among Malaysian women. A random sample of 425 women teachers was taken from 24 secondary schools in Selangor state, Malaysia. The CHBMS was translated into the Malay language, validated by an expert's panel, back translated, and pretested. Analyses included descriptive statistics of all the study variables, reliability estimates, and construct validity using factor analysis. The mean age of the respondents was 37.2 (standard deviation 7.1) years. Factor analysis yielded ten factors for BSE with eigenvalue greater than 1 (four factors more than the original): confidence 1 (ability to differentiate normal and abnormal changes in the breasts), barriers to BSE, susceptibility for breast cancer, benefits of BSE, health motivation 1 (general health), seriousness 1 (fear of breast cancer), confidence 2 (ability to detect size of lumps), seriousness 2 (fear of long-term effects of breast cancer), health motivation 2 (preventive health practice), and confidence 3 (ability to perform BSE correctly). For CBE and mammography scales, seven factors each were identified. Factors for CBE scale include susceptibility, health motivation 1, benefits of CBE, seriousness 1, barriers of CBE, seriousness 2 and health motivation 2. For mammography the scale includes benefits of mammography, susceptibility, health motivation 1, seriousness 1, barriers to mammography seriousness 2 and health motivation 2. Cronbach's alpha reliability coefficients ranged from 0.774 to 0.939 for the subscales. The translated version of the CHBMS was found to be a valid and reliable tool for use with Malaysian women. It can be used easily to evaluate the health beliefs about breast cancer, BSE, CBE and mammography and for planning interventions. For greater applicability, it is recommended that this tool be tested among ethnically diverse populations.

  19. Reliability, validity and factor structure of the CES-D in Iranian elderly.

    PubMed

    Malakouti, Seyed Kazem; Pachana, Nancy A; Naji, Borzooyeh; Kahani, Shamsoddin; Saeedkhani, Mozhdeh

    2015-12-01

    In developing countries such as Iran, elder populations are growing. Due to the high prevalence of depressive disorders among elders, reliable screening instruments for this population are required. The main purpose of this study was to determine the reliability and validity of the Farsi version of the Center for Epidemiological Studies-Depression Scale-10 (CES-D) among Iranian elderly persons. The investigators created the Farsi version of the CES-D-10 by translation and back translation. Two hundred and four cases aged 59 and above completed the questionnaire. The reliability and validity of the translated CES-D-10 was established through comparison with the Composite International Diagnostic Interview (CIDI), a recognized gold standard method for diagnosing major depressive disorder. We used a receiver operating curve (ROC) to determine the optimum cutoff score. The Farsi version of the CED-D-10 displayed acceptable psychometric characteristics, as reflected in internal consistency with Cronbach's alpha, split-half coefficients and test-retest reliability of 0.85, 0.65 and 0.49, respectively. Factor analysis and the varimax rotation resulted in two factors including 'depression' and 'interpersonal relationships'. The Depression factor (introduced as CES-D-8 of the scale) had significant correlation with the 10 items form (r=0.99) with 0.87 alpha coefficient. The ROC showed that the optimum cutoff point is 5 with sensitivity of 82% and specificity of 70%, and positive and negative predictive values of 26% and 98%, respectively, for both of the forms. Both the 10 and 8 items form of the Farsi version have desirable characteristics to be useful as a screening instrument for depressive disorders in Iranian elders, especially in urban areas. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Screening of Chemical Dyes in Traditional Chinese Medicine by HPTLC-MS.

    PubMed

    He, Fengyan; He, Yi; Zheng, Xiaowei; Wang, Ruizhong; Lu, Jing; Dai, Zhong; Ma, Shuangcheng

    2018-05-01

    It has been uncovered that chemical dyes are illegally used in traditional Chinese medicines to brighten color and cover up inferiority, which threaten the safety of patients. In the present study, an HPTLC-MS method was developed for the effective screening of 11 chemical dyes (Sudan I, II, III, and IV; 808 Scarlet; Sudan Red 7B; malachite green; Basic Orange 2; auramine; Orange II; and erythrosine) in traditional Chinese medicine (TCM) raw materials and Chinese patent medicines. Firstly, unwashed HPTLC plates were chosen by comparing the background signals of the TLC plates used directly and prewashed with analytical grade and HPLC grade solvents. Twice developments were conducted to isolate chemical dyes of different polarity. Possible adulterants were preliminarily identified by comparing Rf values and in situ UV-Vis spectra with those of the references. Further confirmation was conducted by tandem MS analysis via an elution head-based TLC-MS interface. Sudan I and IV, 808 Scarlet, and Orange II were successfully detected in eight batches of TCM. The proposed method could be applied as a reliable technology for the screening of chemical dyes in TCM.

  1. High-throughput behavioral screening method for detecting auditory response defects in zebrafish.

    PubMed

    Bang, Pascal I; Yelick, Pamela C; Malicki, Jarema J; Sewell, William F

    2002-08-30

    We have developed an automated, high-throughput behavioral screening method for detecting hearing defects in zebrafish. Our assay monitors a rapid escape reflex in response to a loud sound. With this approach, 36 adult zebrafish, restrained in visually isolated compartments, can be simultaneously assessed for responsiveness to near-field 400 Hz sinusoidal tone bursts. Automated, objective determinations of responses are achieved with a computer program that obtains images at precise times relative to the acoustic stimulus. Images taken with a CCD video camera before and after stimulus presentation are subtracted to reveal a response to the sound. Up to 108 fish can be screened per hour. Over 6500 fish were tested to validate the reliability of the assay. We found that 1% of these animals displayed hearing deficits. The phenotypes of non-responders were further assessed with radiological analysis for defects in the gross morphology of the auditory system. Nearly all of those showed abnormalities in conductive elements of the auditory system: the swim bladder or Weberian ossicles. Copyright 2002 Elsevier Science B.V.

  2. Screening for Posttraumatic Stress Disorder among Somali ex-combatants: A validation study

    PubMed Central

    Odenwald, Michael; Lingenfelder, Birke; Schauer, Maggie; Neuner, Frank; Rockstroh, Brigitte; Hinkel, Harald; Elbert, Thomas

    2007-01-01

    Background In Somalia, a large number of active and former combatants are affected by psychological problems such as Posttraumatic Stress Disorder (PTSD). This disorder impairs their ability to re-integrate into civilian life. However, many screening instruments for Posttraumatic Stress Disorder used in post-conflict settings have limited validity. Here we report on development and validation of a screening tool for PTSD in Somali language with a sample of ex-combatants. Methods We adapted the Posttraumatic Diagnostic Scale (PDS) to reflect linguistic and cultural differences within the Somali community so that local interviewers could be trained to administer the scale. For validation purposes, a randomly selected group of 135 Somali ex-combatants was screened by trained local interviewers; 64 of them were then re-assessed by trained clinical psychologists using the Composite International Diagnostic Interview (CIDI) and the Self-Report Questionnaire (SRQ-20). Results The screening instrument showed good internal consistency (Cronbach's α = .86), convergent validity with the CIDI (sensitivity = .90; specificity = .90) as well as concurrent validity: positive cases showed higher SRQ-20 scores, higher prevalence of psychotic symptoms, and higher levels of intake of the local stimulant drug khat. Compared to a single cut-off score, the multi-criteria scoring, in keeping with the DSM-IV, produced more diagnostic specificity. Conclusion The results provide evidence that our screening instrument is a reliable and valid method to detect PTSD among Somali ex-combatants. A future Disarmament, Demobilization and Reintegration Program in Somalia is recommended to screen for PTSD in order to identify ex-combatants with special psycho-social needs. PMID:17822562

  3. Current and emerging screening methods to identify post-head-emergence frost adaptation in wheat and barley.

    PubMed

    Frederiks, T M; Christopher, J T; Harvey, G L; Sutherland, M W; Borrell, A K

    2012-09-01

    Cereal crops can suffer substantial damage if frosts occur at heading. Identification of post-head-emergence frost (PHEF) resistance in cereals poses a number of unique and difficult challenges. Many decades of research have failed to identify genotypes with PHEF resistance that could offer economically significant benefit to growers. Research and breeding gains have been limited by the available screening systems. Using traditional frost screening systems, genotypes that escape frost injury in trials due to spatial temperature differences and/or small differences in phenology can be misidentified as resistant. We believe that by improving techniques to minimize frost escapes, such 'false-positive' results can be confidently identified and eliminated. Artificial freezing chambers or manipulated natural frost treatments offer many potential advantages but are not yet at the stage where they can be reliably used for frost screening in breeding programmes. Here we describe the development of a novel photoperiod gradient method (PGM) that facilitates screening of genotypes of different phenology under natural field frosts at matched developmental stages. By identifying frost escapes and increasing the efficiency of field screening, the PGM ensures that research effort can be focused on finding genotypes with improved PHEF resistance. To maximize the likelihood of identifying PHEF resistance, we propose that the PGM form part of an integrated strategy to (i) source germplasm;(ii) facilitate high throughput screening; and (iii) permit detailed validation. PGM may also be useful in other studies where either a range of developmental stages and/or synchronized development are desired.

  4. Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.

    PubMed

    Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S

    2014-02-10

    Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.

  5. A Systematic Protein Refolding Screen Method using the DGR Approach Reveals that Time and Secondary TSA are Essential Variables.

    PubMed

    Wang, Yuanze; van Oosterwijk, Niels; Ali, Ameena M; Adawy, Alaa; Anindya, Atsarina L; Dömling, Alexander S S; Groves, Matthew R

    2017-08-24

    Refolding of proteins derived from inclusion bodies is very promising as it can provide a reliable source of target proteins of high purity. However, inclusion body-based protein production is often limited by the lack of techniques for the detection of correctly refolded protein. Thus, the selection of the refolding conditions is mostly achieved using trial and error approaches and is thus a time-consuming process. In this study, we use the latest developments in the differential scanning fluorimetry guided refolding approach as an analytical method to detect correctly refolded protein. We describe a systematic buffer screen that contains a 96-well primary pH-refolding screen in conjunction with a secondary additive screen. Our research demonstrates that this approach could be applied for determining refolding conditions for several proteins. In addition, it revealed which "helper" molecules, such as arginine and additives are essential. Four different proteins: HA-RBD, MDM2, IL-17A and PD-L1 were used to validate our refolding approach. Our systematic protocol evaluates the impact of the "helper" molecules, the pH, buffer system and time on the protein refolding process in a high-throughput fashion. Finally, we demonstrate that refolding time and a secondary thermal shift assay buffer screen are critical factors for improving refolding efficiency.

  6. Techniques to evaluate the importance of common cause degradation on reliability and safety of nuclear weapons.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darby, John L.

    2011-05-01

    As the nuclear weapon stockpile ages, there is increased concern about common degradation ultimately leading to common cause failure of multiple weapons that could significantly impact reliability or safety. Current acceptable limits for the reliability and safety of a weapon are based on upper limits on the probability of failure of an individual item, assuming that failures among items are independent. We expanded the current acceptable limits to apply to situations with common cause failure. Then, we developed a simple screening process to quickly assess the importance of observed common degradation for both reliability and safety to determine if furthermore » action is necessary. The screening process conservatively assumes that common degradation is common cause failure. For a population with between 100 and 5000 items we applied the screening process and conclude the following. In general, for a reliability requirement specified in the Military Characteristics (MCs) for a specific weapon system, common degradation is of concern if more than 100(1-x)% of the weapons are susceptible to common degradation, where x is the required reliability expressed as a fraction. Common degradation is of concern for the safety of a weapon subsystem if more than 0.1% of the population is susceptible to common degradation. Common degradation is of concern for the safety of a weapon component or overall weapon system if two or more components/weapons in the population are susceptible to degradation. Finally, we developed a technique for detailed evaluation of common degradation leading to common cause failure for situations that are determined to be of concern using the screening process. The detailed evaluation requires that best estimates of common cause and independent failure probabilities be produced. Using these techniques, observed common degradation can be evaluated for effects on reliability and safety.« less

  7. Identification of FVIII gene mutations in patients with hemophilia A using new combinatorial sequencing by hybridization

    PubMed Central

    Chetta, M.; Drmanac, A.; Santacroce, R.; Grandone, E.; Surrey, S.; Fortina, P.; Margaglione, M.

    2008-01-01

    BACKGROUND: Standard methods of mutation detection are time consuming in Hemophilia A (HA) rendering their application unavailable in some analysis such as prenatal diagnosis. OBJECTIVES: To evaluate the feasibility of combinatorial sequencing-by-hybridization (cSBH) as an alternative and reliable tool for mutation detection in FVIII gene. PATIENTS/METHODS: We have applied a new method of cSBH that uses two different colors for detection of multiple point mutations in the FVIII gene. The 26 exons encompassing the HA gene were analyzed in 7 newly diagnosed Italian patients and in 19 previously characterized individuals with FVIII deficiency. RESULTS: Data show that, when solution-phase TAMRA and QUASAR labeled 5-mer oligonucleotide sets mixed with unlabeled target PCR templates are co-hybridized in the presence of DNA ligase to universal 6-mer oligonucleotide probe-based arrays, a number of mutations can be successfully detected. The technique was reliable also in identifying a mutant FVIII allele in an obligate heterozygote. A novel missense mutation (Leu1843Thr) in exon 16 and three novel neutral polymorphisms are presented with an updated protocol for 2-color cSBH. CONCLUSIONS: cSBH is a reliable tool for mutation detection in FVIII gene and may represent a complementary method for the genetic screening of HA patients. PMID:20300295

  8. The Oral Speech Mechanism Screening Examination (OSMSE).

    ERIC Educational Resources Information Center

    St. Louis, Kenneth O.; Ruscello, Dennis M.

    Although speech-language pathologists are expected to be able to administer and interpret oral examinations, there are currently no screening tests available that provide careful administration instructions and data for intra-examiner and inter-examiner reliability. The Oral Speech Mechanism Screening Examination (OSMSE) is designed primarily for…

  9. Approaches to virtual screening and screening library selection.

    PubMed

    Wildman, Scott A

    2013-01-01

    The ease of access to virtual screening (VS) software in recent years has resulted in a large increase in literature reports. Over 300 publications in the last year report the use of virtual screening techniques to identify new chemical matter or present the development of new virtual screening techniques. The increased use is accompanied by a corresponding increase in misuse and misinterpretation of virtual screening results. This review aims to identify many of the common difficulties associated with virtual screening and allow researchers to better assess the reliability of their virtual screening effort.

  10. A High-Throughput Assay for Screening of Natural Products that Enhanced Tumoricidal Activity of NK Cells.

    PubMed

    Gong, Chenyuan; Ni, Zhongya; Yao, Chao; Zhu, Xiaowen; Ni, Lulu; Wang, Lixin; Zhu, Shiguo

    2015-01-01

    Recently, immunotherapy has shown a lot of promise in cancer treatment and different immune cell types are involved in this endeavor. Among different immune cell populations, NK cells are also an important component in unleashing the therapeutic activity of immune cells. Therefore, in order to enhance the tumoricidal activity of NK cells, identification of new small-molecule natural products is important. Despite the availability of different screening methods for identification of natural products, a simple, economic and high-throughput method is lacking. Hence, in this study, we have developed a high-throughput assay for screening and indentifying natural products that can enhance NK cell-mediated killing of cancer cells. We expanded human NK cell population from human peripheral blood mononuclear cells (PBMCs) by culturing these PBMCs with membrane-bound IL-21 and CD137L engineered K562 cells. Next, expanded NK cells were co-cultured with non-small cell lung cancer (NSCLC) cells with or without natural products and after 24 h of co-culturing, harvested supernatants were analyzed for IFN-γ secretions by ELISA method. We screened 502 natural products and identified that 28 candidates has the potential to induce IFN-γ secretion by NK cells to varying degrees. Among the 28 natural product candidates, we further confirmed and analyzed the potential of one molecule, andrographolide. It actually increased IFN-γ secretion by NK cells and enhanced NK cell-mediated killing of NSCLC cells. Our results demonstrated that this IFN-γ based high-throughput assay for screening of natural products for NK cell tumoricidal activity is a simple, economic and reliable method.

  11. Salivary diagnostics and its impact in dentistry, research, education, and the professional community.

    PubMed

    Slavkin, H C; Fox, C H; Meyer, D M

    2011-10-01

    Oral fluid-based (salivary) tests have the potential to create practical, point-of-care clinical instruments that are convenient, practical, and comfortable to use in dentistry and medicine. Currently, there are no simple, accurate, and inexpensive sampling, screening, or detection methods to support definitive diagnostic platforms across dental and medical disciplines. Though the benefits from advancing screening and detection technologies seem eminent, analytical, chemical, molecular, genetic, and protein markers are still under development. Clinical applications in patient care must be validated independently to ensure that they are clinically accurate, reliable, precise, and uniformly consistent for screening and detecting specific diseases or conditions. As technology designed to improve patient care through risk assessment, prevention, and disease management is transferred into clinical practice, dentistry may need to reassess its role in general health care. © International & American Associations for Dental Research

  12. Improving the photostability of bright monomeric orange and red fluorescent proteins.

    PubMed

    Shaner, Nathan C; Lin, Michael Z; McKeown, Michael R; Steinbach, Paul A; Hazelwood, Kristin L; Davidson, Michael W; Tsien, Roger Y

    2008-06-01

    All organic fluorophores undergo irreversible photobleaching during prolonged illumination. Although fluorescent proteins typically bleach at a substantially slower rate than many small-molecule dyes, in many cases the lack of sufficient photostability remains an important limiting factor for experiments requiring large numbers of images of single cells. Screening methods focusing solely on brightness or wavelength are highly effective in optimizing both properties, but the absence of selective pressure for photostability in such screens leads to unpredictable photobleaching behavior in the resulting fluorescent proteins. Here we describe an assay for screening libraries of fluorescent proteins for enhanced photostability. With this assay, we developed highly photostable variants of mOrange (a wavelength-shifted monomeric derivative of DsRed from Discosoma sp.) and TagRFP (a monomeric derivative of eqFP578 from Entacmaea quadricolor) that maintain most of the beneficial qualities of the original proteins and perform as reliably as Aequorea victoria GFP derivatives in fusion constructs.

  13. Investigation of light source and scattering medium related to vapor-screen flow visualization in a supersonic wind tunnel

    NASA Technical Reports Server (NTRS)

    Snow, W. L.; Morris, O. A.

    1984-01-01

    Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow.

  14. THE 6-MINUTE WALK TEST AND OTHER CLINICAL ENDPOINTS IN DUCHENNE MUSCULAR DYSTROPHY: RELIABILITY, CONCURRENT VALIDITY, AND MINIMAL CLINICALLY IMPORTANT DIFFERENCES FROM A MULTICENTER STUDY

    PubMed Central

    McDonald, Craig M; Henricson, Erik K; Abresch, R Ted; Florence, Julaine; Eagle, Michelle; Gappmaier, Eduard; Glanzman, Allan M; Spiegel, Robert; Barth, Jay; Elfring, Gary; Reha, Allen; Peltz, Stuart W

    2013-01-01

    Introduction: An international clinical trial enrolled 174 ambulatory males ≥5 years old with nonsense mutation Duchenne muscular dystrophy (nmDMD). Pretreatment data provide insight into reliability, concurrent validity, and minimal clinically important differences (MCIDs) of the 6-minute walk test (6MWT) and other endpoints. Methods: Screening and baseline evaluations included the 6-minute walk distance (6MWD), timed function tests (TFTs), quantitative strength by myometry, the PedsQL, heart rate–determined energy expenditure index, and other exploratory endpoints. Results: The 6MWT proved feasible and reliable in a multicenter context. Concurrent validity with other endpoints was excellent. The MCID for 6MWD was 28.5 and 31.7 meters based on 2 statistical distribution methods. Conclusions: The ratio of MCID to baseline mean is lower for 6MWD than for other endpoints. The 6MWD is an optimal primary endpoint for Duchenne muscular dystrophy (DMD) clinical trials that are focused therapeutically on preservation of ambulation and slowing of disease progression. Muscle Nerve 48: 357–368, 2013 PMID:23674289

  15. Rapid and reliable detection and identification of GM events using multiplex PCR coupled with oligonucleotide microarray.

    PubMed

    Xu, Xiaodan; Li, Yingcong; Zhao, Heng; Wen, Si-yuan; Wang, Sheng-qi; Huang, Jian; Huang, Kun-lun; Luo, Yun-bo

    2005-05-18

    To devise a rapid and reliable method for the detection and identification of genetically modified (GM) events, we developed a multiplex polymerase chain reaction (PCR) coupled with a DNA microarray system simultaneously aiming at many targets in a single reaction. The system included probes for screening gene, species reference gene, specific gene, construct-specific gene, event-specific gene, and internal and negative control genes. 18S rRNA was combined with species reference genes as internal controls to assess the efficiency of all reactions and to eliminate false negatives. Two sets of the multiplex PCR system were used to amplify four and five targets, respectively. Eight different structure genes could be detected and identified simultaneously for Roundup Ready soybean in a single microarray. The microarray specificity was validated by its ability to discriminate two GM maizes Bt176 and Bt11. The advantages of this method are its high specificity and greatly reduced false-positives and -negatives. The multiplex PCR coupled with microarray technology presented here is a rapid and reliable tool for the simultaneous detection of GM organism ingredients.

  16. Screening of Cognitive Impairment in Schizophrenia: Reliability, Sensitivity, and Specificity of the Repeatable Battery for the Assessment of Neuropsychological Status in a Spanish Sample.

    PubMed

    De la Torre, Gabriel G; Perez, Maria J; Ramallo, Miguel A; Randolph, Christopher; González-Villegas, Macarena Bernal

    2016-04-01

    In recent years, a number of studies focusing on the evaluation of neuropsychological deficits in individuals with schizophrenia have shown deficits that include several cognitive functions. Attention deficits as well as memory or executive function deficits are common in this kind of disorder together with sustained attention problems, working memory deficiencies, and problem-solving difficulties, among many others. Currently, the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) is gaining special importance in the evaluation of the cognitive deficits associated with schizophrenia. In this article, we describe an RBANS screening in a sample of 88 Spanish patients diagnosed with schizophrenia. We also aimed to check the battery's reliability, sensitivity, and specificity in the studied sample. We performed a comparative study with 88 healthy participants. The results showed a reliability index value of α = .795 and an item value of α = .762. For total test reliability, we obtained an index value of α = .761 and an item value of α = .762. Sensitivity score was 87.5% and specificity 86.4%. RBANS obtained good reliability, sensitivity, and specificity scores and represents a good screening tool in detecting cognitive deficits associated with schizophrenia. © The Author(s) 2015.

  17. Autism detection in early childhood (ADEC): reliability and validity data for a Level 2 screening tool for autistic disorder.

    PubMed

    Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna

    2014-03-01

    The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA

  18. Adaptation and Assessment of Reliability and Validity of the Greek Version of the Ohkuma Questionnaire for Dysphagia Screening

    PubMed Central

    Papadopoulou, Soultana L.; Exarchakos, Georgios; Christodoulou, Dimitrios; Theodorou, Stavroula; Beris, Alexandre; Ploumis, Avraam

    2016-01-01

    Introduction The Ohkuma questionnaire is a validated screening tool originally used to detect dysphagia among patients hospitalized in Japanese nursing facilities. Objective The purpose of this study is to evaluate the reliability and validity of the adapted Greek version of the Ohkuma questionnaire. Methods Following the steps for cross-cultural adaptation, we delivered the validated Ohkuma questionnaire to 70 patients (53 men, 17 women) who were either suffering from dysphagia or not. All of them completed the questionnaire a second time within a month. For all of them, we performed a bedside and VFSS study of dysphagia and asked participants to undergo a second VFSS screening, with the exception of nine individuals. Statistical analysis included measurement of internal consistency with Cronbach's α coefficient, reliability with Cohen's Kappa, Pearson's correlation coefficient and construct validity with categorical components, and One-Way Anova test. Results According to Cronbach's α coefficient (0.976) for total score, there was high internal consistency for the Ohkuma Dysphagia questionnaire. Test-retest reliability (Cohen's Kappa) ranged from 0.586 to 1.00, exhibiting acceptable stability. We also estimated the Pearson's correlation coefficient for the test-retest total score, which reached high levels (0.952; p = 0.000). The One-Way Anova test in the two measurement times showed statistically significant correlation in both measurements (p = 0.02 and p = 0.016). Conclusion The adapted Greek version of the questionnaire is valid and reliable and can be used for the screening of dysphagia in the Greek-speaking patients. PMID:28050209

  19. Application of Short Screening Tools for Post-Traumatic Stress Disorder in the Korean Elderly Population

    PubMed Central

    Jang, Yu Jin; Chung, Hae Gyung; Choi, Jin Hee; Kim, Tae Yong; So, Hyung Seok

    2016-01-01

    Objective Post-traumatic stress disorder (PTSD) is often missed or incorrectly diagnosed in primary care settings. Although brief screening instruments may be useful in detecting PTSD, an adequate validation study has not been conducted with older adults. This study aimed to evaluate the reliability and validity of the Korean version of the primary care PTSD screen (PC-PTSD) and single-item PTSD screener (SIPS) in elderly veterans. Methods The PC-PTSD and SIPS assessments were translated into Korean, with a back-translation to the original language to verify accuracy. Vietnamese war veterans [separated into a PTSD group (n=41) and a non-PTSD group (n=99)] participated in several psychometric assessments, including the Korean versions of the PC-PTSD (PC-PTSD-K), SIPS (SIPS-K), a structured clinical interview from the Diagnostic and Statistical Manual of Mental Disorders-IV(SCID), and PTSD checklist(PCL). Results The PC-PTSD-K showed high internal consistency (Cronbach α=0.76), and the test-retest reliability of the PC-PTSD-K and SIPS-K were also high (r=0.97 and r=0.91, respectively). A total score of 3 from the PC-PTSD-K yielded the highest diagnostic efficiency, with sensitivity and specificity values of 0.90 and 0.86, respectively. The 'bothered a lot' response level from the SIPS-K showed the highest diagnostic efficiency, with sensitivity and specificity values of 0.85 and 0.89, respectively. Conclusion Our findings suggest that both PC-PTSD-K and SIPS-K have good psychometric properties with high validity and reliability for detecting PTSD symptoms in elderly Korean veterans. However, further research will be necessary to increase our understanding of PTSD characteristics in diverse groups with different types of trauma. PMID:27482241

  20. Reliability and validity of DS-ADHD: A decision support system on attention deficit hyperactivity disorders.

    PubMed

    Chu, Kuo-Chung; Huang, Yu-Shu; Tseng, Chien-Fu; Huang, Hsin-Jou; Wang, Chih-Huan; Tai, Hsin-Yi

    2017-03-01

    The purpose of this study is to examine the reliability of the clinical use of the self-built decision support system, diagnosis-supported attention deficit hyperactivity disorder (DS-ADHD), in an effort to develop the DS-ADHD system, by probing into the development of indicating patterns of past screening support systems for ADHD. The study collected data based on 107 subjects, who were divided into two groups, non-ADHD and ADHD, based on the doctor's determination, using the DSM-IV diagnostic standards. The two groups then underwent Test of Variables of Attention (TOVA) and DS-ADHD testing. The survey and testing results underwent one-way ANOVA and split-half method statistical analysis, in order to further understand whether there were any differences between the DS-ADHD and the identification tools used in today's clinical trials. The results of the study are as follows: 1) The ROC area between the TOVA and the clinical identification rate is 0.787 (95% confidence interval: 0.701-0.872); 2) The ROC area between the DS-ADHD and the clinical identification rate is 0.867 (95% confidence interval: 0.801-0.933). The study results show that DS-ADHD has the characteristics of screening for ADHD, based on its reliability and validity. It does not display any statistical differences when compared with TOVA systems that are currently on the market. However, the system is more effective and the accuracy rate is better than TOVA. It is a good tool to screen ADHD not only in Chinese children, but also in western country. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Reliability, validity, and clinical use of the Dominic Interactive: a DSM-based, self-report screen for school-aged children.

    PubMed

    Bergeron, Lise; Berthiaume, Claude; St-Georges, Marie; Piché, Geneviève; Smolla, Nicole

    2013-08-01

    As no single informant can be considered the gold standard of child psychopathology, interviewing of children regarding their own symptoms is necessary. Our study focused on the reliability, validity, and clinical use of the Dominic Interactive (DI), a multimedia self-report screen to assess symptoms for the most frequent Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision, mental disorders in school-aged children. A sample of 585 children aged 6 to 11 years from the community and psychiatric clinics was used to analyze the internal consistency, the test-retest estimate of reliability, and the criterion-related validity of the DI against the referral status. In addition, cross-informant correlation coefficients between this instrument (child report) and the Child Symptom Inventory (parent report) were explored in a subsample of 292 participants. For the total sample, Cronbach alpha coefficients ranged from 0.63 to 0.91. Test-retest kappas varied from 0.42 to 0.62 for categories based on cut-off points, except for specific phobias. Intraclass correlation coefficients ranged from 0.70 to 0.81 for symptom scales. The DI discriminated between referred and non-referred children in psychiatric clinics for all symptom scales. Significant cross-informant correlation coefficients were higher for the externalizing symptoms (0.35 to 0.48) than the internalizing symptoms (0.14 to 0.27). Findings of our study reasonably support adequate psychometric properties of the DI. This instrument offers a developmentally sensitive screening method to obtain unique information from young children about their mental health problems in front-line services, psychiatric clinics, and research settings.

  2. Quantification of a bacterial secondary metabolite by SERS combined with SLM extraction for bioprocess monitoring.

    PubMed

    Morelli, Lidia; Andreasen, Sune Zoëga; Jendresen, Christian Bille; Nielsen, Alex Toftgaard; Emnéus, Jenny; Zór, Kinga; Boisen, Anja

    2017-11-20

    During the last few decades, great advances have been reached in high-throughput design and building of genetically engineered microbial strains, leading to a need for fast and reliable screening methods. We developed and optimized a microfluidic supported liquid membrane (SLM) extraction device and combined it with surface enhanced Raman scattering (SERS) sensing for the screening of a biological process, namely for the quantification of a bacterial secondary metabolite, p-coumaric acid (pHCA), produced by Escherichia coli. The microfluidic device proved to be robust and reusable, enabling efficient removal of interfering compounds from the real samples, reaching more than 13-fold up-concentration of the donor at 10 μL min -1 flow rate. With this method, we quantified pHCA directly from the bacterial supernatant, distinguishing between various culture conditions based on the pHCA production yield. The obtained data showed good correlation with HPLC analysis.

  3. Rapid Assessment of Contrast Sensitivity with Mobile Touch-screens

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.

    2013-01-01

    The availability of low-cost high-quality touch-screen displays in modern mobile devices has created opportunities for new approaches to routine visual measurements. Here we describe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. We will demonstrate a prototype for Apple Computer's iPad-iPod-iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing,

  4. Clinical utility of the Chinese version of the Pediatric Daytime Sleepiness Scale in children with obstructive sleep apnea syndrome and narcolepsy.

    PubMed

    Yang, Chien-Ming; Huang, Yu-Shu; Song, Yu-Chen

    2010-04-01

    The present study examined the psychometric properties of the Chinese version of the Pediatric Daytime Sleepiness Scale (PDSS) and the utility of the PDSS as a screening tool for pathological daytime sleepiness in teenagers with obstructive sleep apnea (OSA) and narcolepsy. The PDSS was first administered to 238 middle and high school students to assess the reliability of the scale, and then administered to 28 teenagers with OSA, 31 teenagers with narcolepsy, and 34 normal controls to evaluate its clinical utility. Test-retest reliability and internal consistency were acceptable. The PDSS scores were significantly higher in narcoleptic subjects than in subjects with OSA, and higher in OSA syndrome (OSAS) subjects than normal controls. Furthermore, the scores decreased in narcoleptic subjects after medical treatment. Both reliability and validity were proven to be good. As a screening tool for narcolepsy, receiver operator characteristic (ROC) curve analysis showed that the PDSS, with a cut-off score of 16/17, had good sensitivity (87.1%) and fair specificity (74.3%) for identifying individuals with narcolepsy. When used for screening OSA, however, the differentiating power was not as good. The PDSS is a reliable and valid tool for the measurement of sleepiness in clinical youth populations. When used as a screening tool, it is useful for sleep disorders involving more severe pathological sleepiness, as in narcolepsy.

  5. Screening for personality disorder in incarcerated adolescent boys: preliminary validation of an adolescent version of the standardised assessment of personality - abbreviated scale (SAPAS-AV).

    PubMed

    Kongerslev, Mickey; Moran, Paul; Bo, Sune; Simonsen, Erik

    2012-07-30

    Personality disorder (PD) is associated with significant functional impairment and an elevated risk of violent and suicidal behaviour. The prevalence of PD in populations of young offenders is likely to be high. However, because the assessment of PD is time-consuming, it is not routinely assessed in this population. A brief screen for the identification of young people who might warrant further detailed assessment of PD could be particularly valuable for clinicians and researchers working in juvenile justice settings. We adapted a rapid screen for the identification of PD in adults (Standardised Assessment of Personality - Abbreviated Scale; SAPAS) for use with adolescents and then carried out a study of the reliability and validity of the adapted instrument in a sample of 80 adolescent boys in secure institutions. Participants were administered the screen and shortly after an established diagnostic interview for DSM-IV PDs. Nine days later the screen was readministered. A score of 3 or more on the screening interview correctly identified the presence of DSM-IV PD in 86% of participants, yielding a sensitivity and specificity of 0.87 and 0.86 respectively. Internal consistency was modest but comparable to the original instrument. 9-days test-retest reliability for the total score was excellent. Convergent validity correlations with the total number of PD criteria were large. This study provides preliminary evidence of the validity, reliability, and usefulness of the screen in secure institutions for adolescent male offenders. It can be used in juvenile offender institutions with limited resources, as a brief, acceptable, staff-administered routine screen to identify individuals in need of further assessment of PD or by researchers conducting epidemiological surveys.

  6. Translations on USSR Science and Technology, Physical Sciences and Technology, Number 16

    DTIC Science & Technology

    1977-08-05

    34INVESTIGATION OF SPLITTING OF LIGHT NUCLEI WITH HIGH-ENERGY y -RAYS WITH THE METHOD OF WILSON’S CHAMBER OPERATING IN POWERFUL BEAMS OF ELECTRONIC...boast high reliability, high speed, and extremely modest power requirements. Information oh the Screen Visual display devices greatly facilitate...area of application of these units Includes navigation, control of power systems, machine tools, and manufac- turing processes. Th» ^»abilities of

  7. A comparative study of first-derivative spectrophotometry and column high-performance liquid chromatography applied to the determination of repaglinide in tablets and for dissolution testing.

    PubMed

    AlKhalidi, Bashar A; Shtaiwi, Majed; AlKhatib, Hatim S; Mohammad, Mohammad; Bustanji, Yasser

    2008-01-01

    A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.

  8. Technology-assisted title and abstract screening for systematic reviews: a retrospective evaluation of the Abstrackr machine learning tool.

    PubMed

    Gates, Allison; Johnson, Cydney; Hartling, Lisa

    2018-03-12

    Machine learning tools can expedite systematic review (SR) processes by semi-automating citation screening. Abstrackr semi-automates citation screening by predicting relevant records. We evaluated its performance for four screening projects. We used a convenience sample of screening projects completed at the Alberta Research Centre for Health Evidence, Edmonton, Canada: three SRs and one descriptive analysis for which we had used SR screening methods. The projects were heterogeneous with respect to search yield (median 9328; range 5243 to 47,385 records; interquartile range (IQR) 15,688 records), topic (Antipsychotics, Bronchiolitis, Diabetes, Child Health SRs), and screening complexity. We uploaded the records to Abstrackr and screened until it made predictions about the relevance of the remaining records. Across three trials for each project, we compared the predictions to human reviewer decisions and calculated the sensitivity, specificity, precision, false negative rate, proportion missed, and workload savings. Abstrackr's sensitivity was > 0.75 for all projects and the mean specificity ranged from 0.69 to 0.90 with the exception of Child Health SRs, for which it was 0.19. The precision (proportion of records correctly predicted as relevant) varied by screening task (median 26.6%; range 14.8 to 64.7%; IQR 29.7%). The median false negative rate (proportion of records incorrectly predicted as irrelevant) was 12.6% (range 3.5 to 21.2%; IQR 12.3%). The workload savings were often large (median 67.2%, range 9.5 to 88.4%; IQR 23.9%). The proportion missed (proportion of records predicted as irrelevant that were included in the final report, out of the total number predicted as irrelevant) was 0.1% for all SRs and 6.4% for the descriptive analysis. This equated to 4.2% (range 0 to 12.2%; IQR 7.8%) of the records in the final reports. Abstrackr's reliability and the workload savings varied by screening task. Workload savings came at the expense of potentially missing relevant records. How this might affect the results and conclusions of SRs needs to be evaluated. Studies evaluating Abstrackr as the second reviewer in a pair would be of interest to determine if concerns for reliability would diminish. Further evaluations of Abstrackr's performance and usability will inform its refinement and practical utility.

  9. CARE3MENU- A CARE III USER FRIENDLY INTERFACE

    NASA Technical Reports Server (NTRS)

    Pierce, J. L.

    1994-01-01

    CARE3MENU generates an input file for the CARE III program. CARE III is used for reliability prediction of complex, redundant, fault-tolerant systems including digital computers, aircraft, nuclear and chemical control systems. The CARE III input file often becomes complicated and is not easily formatted with a text editor. CARE3MENU provides an easy, interactive method of creating an input file by automatically formatting a set of user-supplied inputs for the CARE III system. CARE3MENU provides detailed on-line help for most of its screen formats. The reliability model input process is divided into sections using menu-driven screen displays. Each stage, or set of identical modules comprising the model, must be identified and described in terms of number of modules, minimum number of modules for stage operation, and critical fault threshold. The fault handling and fault occurence models are detailed in several screens by parameters such as transition rates, propagation and detection densities, Weibull or exponential characteristics, and model accuracy. The system fault tree and critical pairs fault tree screens are used to define the governing logic and to identify modules affected by component failures. Additional CARE3MENU screens prompt the user for output options and run time control values such as mission time and truncation values. There are fourteen major screens, many with default values and HELP options. The documentation includes: 1) a users guide with several examples of CARE III models, the dialog required to input them to CARE3MENU, and the output files created; and 2) a maintenance manual for assistance in changing the HELP files and modifying any of the menu formats or contents. CARE3MENU is written in FORTRAN 77 for interactive execution and has been implemented on a DEC VAX series computer operating under VMS. This program was developed in 1985.

  10. Development and evaluation of a new survey instrument to measure the quality of colorectal cancer screening decisions.

    PubMed

    Sepucha, Karen R; Feibelmann, Sandra; Cosenza, Carol; Levin, Carrie A; Pignone, Michael

    2014-08-20

    Guidelines for colorectal cancer screening recommend that patients be informed about options and be able to select preferred method of screening; however, there are no existing measures available to assess whether this happens. Colorectal Cancer Screening Decision Quality Instrument (CRC-DQI) includes knowledge items and patients' goals and concerns. Items were generated through literature review and qualitative work with patients and providers. Hypotheses relating to the acceptability, feasibility, discriminant validity and retest reliability of the survey were examined using data from three studies: (1) 2X2 randomized study of participants recruited online, (2) cross-sectional sample of patients recruited in community health clinics, and (3) cross-sectional sample of providers recruited from American Medical Association Master file. 338 participants were recruited online, 94 participants were recruited from community health centers, and 115 physicians were recruited. The CRC-DQI was feasible and acceptable with low missing data and high response rates for both online and paper-based administrations. The knowledge score was able to discriminate between those who had seen a decision aid or not (84% vs. 64%, p < 0.001) and between providers, online patients and clinic patients (89% vs. 74% vs. 41%, p < 0.001 for all comparisons). The knowledge score and most of the goals had adequate retest reliability. About half of the participants received a test that matched their goals (47% and 51% in online and clinic samples respectively). Many respondents who had never been screened had goals that indicated a preference for colonoscopy. A minority of respondents in the online (21%) and in clinic (2%) samples were both well informed and received a test that matched their goals. The CRC-DQI demonstrated good psychometric properties in diverse samples, and across different modes of administration. Few respondents made high quality decisions about colon cancer screening.

  11. A rapid and sensitive fluorometric method for the quantitative analysis of snake venom metalloproteases and their inhibitors.

    PubMed

    Biardi, J E; Nguyen, K T; Lander, S; Whitley, M; Nambiar, K P

    2011-02-01

    Metalloproteases are responsible for the hemorrhagic effects of many snake venoms and contribute to other pathways that lead to local tissue damage. Methods that quantify snake venom metalloproteases (SVMP) are therefore valuable tools in research on the clinical, physiological, and biochemical effects of envenomation. Comparative analysis of individual, population, and species differences requires screening of large numbers of samples and treatments, and therefore require a method of quantifying SVMP activity that is simple, rapid, and sensitive. This paper demonstrates the properties of a new fluorometric assay of SVMP activity that can provide a measure of metalloprotease activity in 1 h. The assay is reliable, with variation among replicates sufficiently small to reliably detect differences in between species (F(19,60) = 2924, p < 0.001), even for those venoms with low overall activity. It is also sensitive enough to detect differences among venoms using <2 ng of whole venom protein. We provide an example use of this assay to detect the presence of natural SVMP inhibitors in minute samples of blood plasma from rock squirrels (S. variegatus), a natural prey species for North American rattlesnakes. We propose this assay is a useful addition to the set of tools used to characterize venoms, as well as high-throughput screening of natural or synthetic inhibitors, or other novel therapeutic agents against SVMP effects. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Automated breast tissue density assessment using high order regional texture descriptors in mammography

    NASA Astrophysics Data System (ADS)

    Law, Yan Nei; Lieng, Monica Keiko; Li, Jingmei; Khoo, David Aik-Aun

    2014-03-01

    Breast cancer is the most common cancer and second leading cause of cancer death among women in the US. The relative survival rate is lower among women with a more advanced stage at diagnosis. Early detection through screening is vital. Mammography is the most widely used and only proven screening method for reliably and effectively detecting abnormal breast tissues. In particular, mammographic density is one of the strongest breast cancer risk factors, after age and gender, and can be used to assess the future risk of disease before individuals become symptomatic. A reliable method for automatic density assessment would be beneficial and could assist radiologists in the evaluation of mammograms. To address this problem, we propose a density classification method which uses statistical features from different parts of the breast. Our method is composed of three parts: breast region identification, feature extraction and building ensemble classifiers for density assessment. It explores the potential of the features extracted from second and higher order statistical information for mammographic density classification. We further investigate the registration of bilateral pairs and time-series of mammograms. The experimental results on 322 mammograms demonstrate that (1) a classifier using features from dense regions has higher discriminative power than a classifier using only features from the whole breast region; (2) these high-order features can be effectively combined to boost the classification accuracy; (3) a classifier using these statistical features from dense regions achieves 75% accuracy, which is a significant improvement from 70% accuracy obtained by the existing approaches.

  13. The development and reliability of a simple field based screening tool to assess core stability in athletes.

    PubMed

    O'Connor, S; McCaffrey, N; Whyte, E; Moran, K

    2016-07-01

    To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Inter-Rater Reliability and Downstream Financial Implications of Electrocardiography Screening in Young Athletes.

    PubMed

    Dhutia, Harshil; Malhotra, Aneil; Yeo, Tee Joo; Ster, Irina Chis; Gabus, Vincent; Steriotis, Alexandros; Dores, Helder; Mellor, Greg; García-Corrales, Carmen; Ensam, Bode; Jayalapan, Viknesh; Ezzat, Vivienne Anne; Finocchiaro, Gherardo; Gati, Sabiha; Papadakis, Michael; Tome-Esteban, Maria; Sharma, Sanjay

    2017-08-01

    Preparticipation screening for cardiovascular disease in young athletes with electrocardiography is endorsed by the European Society of Cardiology and several major sporting organizations. One of the concerns of the ECG as a screening test in young athletes relates to the potential for variation in interpretation. We investigated the degree of variation in ECG interpretation in athletes and its financial impact among cardiologists of differing experience. Eight cardiologists (4 with experience in screening athletes) each reported 400 ECGs of consecutively screened young athletes according to the 2010 European Society of Cardiology recommendations, Seattle criteria, and refined criteria. Cohen κ coefficient was used to calculate interobserver reliability. Cardiologists proposed secondary investigations after ECG interpretation, the costs of which were based on the UK National Health Service tariffs. Inexperienced cardiologists were more likely to classify an ECG as abnormal compared with experienced cardiologists (odds ratio, 1.44; 95% confidence interval, 1.03-2.02). Modification of ECG interpretation criteria improved interobserver reliability for categorizing an ECG as abnormal from poor (2010 European Society of Cardiology recommendations; κ=0.15) to moderate (refined criteria; κ=0.41) among inexperienced cardiologists; however, interobserver reliability was moderate for all 3 criteria among experienced cardiologists (κ=0.40-0.53). Inexperienced cardiologists were more likely to refer athletes for further evaluation compared with experienced cardiologists (odds ratio, 4.74; 95% confidence interval, 3.50-6.43) with poorer interobserver reliability (κ=0.22 versus κ=0.47). Interobserver reliability for secondary investigations after ECG interpretation ranged from poor to fair among inexperienced cardiologists (κ=0.15-0.30) and fair to moderate among experienced cardiologists (κ=0.21-0.46). The cost of cardiovascular evaluation per athlete was $175 (95% confidence interval, $142-$228) and $101 (95% confidence interval, $83-$131) for inexperienced and experienced cardiologists, respectively. Interpretation of the ECG in athletes and the resultant cascade of investigations are highly physician dependent even in experienced hands with important downstream financial implications, emphasizing the need for formal training and standardized diagnostic pathways. © 2017 American Heart Association, Inc.

  15. Is the Bayley Scales of Infant and Toddler Developmental Screening Test, Valid and Reliable for Persian Speaking Children?

    PubMed

    Soleimani, Farin; Azari, Nadia; Vameghi, Roshanak; Sajedi, Firoozeh; Shahshahani, Soheila; Karimi, Hossein; Kraskian, Adis; Shahrokhi, Amin; Teymouri, Robab; Gharib, Masoud

    2016-10-01

    Advances in perinatal and neonatal care have substantially improved the survival of at-risk infants over the past two decades. The purpose of this study was to assess the reliability and validity of the Bayley Scales of infant and toddler developmental Screening test in Persian-speaking children. This was a cross-sectional prospective study of 403 children aged 1 - 42-months. The Bayley scales screening instrument, which consists of five domains (cognitive, receptive, and expressive communication and fine and gross motor items), was used to measure infants' and toddlers' development. The psychometric properties examined included the face and content validity of the scale, in addition to cultural and linguistic modifications to the scale and its test-retest and inter-rater reliability. An expert team changed some of the test items relating to cultural and linguistic issues. In almost all the age groups, cultural or linguistic changes were made to items in the communication domains. According to Cronbach's alpha for internal consistency, the reliability of the cognitive scale was r = 0.79, and the reliability of the receptive scale was r = 0.76. The reliability for expressive communication, fine motor, and gross motor scales was r = 0.81, r = 0.80, and r = 0.81, respectively. The construct validity of the tests was confirmed using a factor analysis and comparison of the mean scores of the age groups. The intra- and inter-rater reliabilities of the Bayley Scales were good-to-excellent. The results indicated that the Bayley Scales had a high level of reliability in the present study. Thus, the scale can be used in a Persian population.

  16. Rater reliability and construct validity of a mobile application for posture analysis

    PubMed Central

    Szucs, Kimberly A.; Brown, Elena V. Donoso

    2018-01-01

    [Purpose] Measurement of posture is important for those with a clinical diagnosis as well as researchers aiming to understand the impact of faulty postures on the development of musculoskeletal disorders. A reliable, cost-effective and low tech posture measure may be beneficial for research and clinical applications. The purpose of this study was to determine rater reliability and construct validity of a posture screening mobile application in healthy young adults. [Subjects and Methods] Pictures of subjects were taken in three standing positions. Two raters independently digitized the static standing posture image twice. The app calculated posture variables, including sagittal and coronal plane translations and angulations. Intra- and inter-rater reliability were calculated using the appropriate ICC models for complete agreement. Construct validity was determined through comparison of known groups using repeated measures ANOVA. [Results] Intra-rater reliability ranged from 0.71 to 0.99. Inter-rater reliability was good to excellent for all translations. ICCs were stronger for translations versus angulations. The construct validity analysis found that the app was able to detect the change in the four variables selected. [Conclusion] The posture mobile application has demonstrated strong rater reliability and preliminary evidence of construct validity. This application may have utility in clinical and research settings. PMID:29410561

  17. Rater reliability and construct validity of a mobile application for posture analysis.

    PubMed

    Szucs, Kimberly A; Brown, Elena V Donoso

    2018-01-01

    [Purpose] Measurement of posture is important for those with a clinical diagnosis as well as researchers aiming to understand the impact of faulty postures on the development of musculoskeletal disorders. A reliable, cost-effective and low tech posture measure may be beneficial for research and clinical applications. The purpose of this study was to determine rater reliability and construct validity of a posture screening mobile application in healthy young adults. [Subjects and Methods] Pictures of subjects were taken in three standing positions. Two raters independently digitized the static standing posture image twice. The app calculated posture variables, including sagittal and coronal plane translations and angulations. Intra- and inter-rater reliability were calculated using the appropriate ICC models for complete agreement. Construct validity was determined through comparison of known groups using repeated measures ANOVA. [Results] Intra-rater reliability ranged from 0.71 to 0.99. Inter-rater reliability was good to excellent for all translations. ICCs were stronger for translations versus angulations. The construct validity analysis found that the app was able to detect the change in the four variables selected. [Conclusion] The posture mobile application has demonstrated strong rater reliability and preliminary evidence of construct validity. This application may have utility in clinical and research settings.

  18. Development and validation of a brief trauma screening measure for children: The Child Trauma Screen.

    PubMed

    Lang, Jason M; Connell, Christian M

    2017-05-01

    Childhood exposure to trauma, including violence and abuse, is a major public health concern that has resulted in increased efforts to promote trauma-informed child-serving systems. Trauma screening is an important component of such trauma-informed systems, yet widespread use of trauma screening is rare in part due to the lack of brief, validated trauma screening measures for children. We describe development and validation of the Child Trauma Screen (CTS), a 10-item screening measure of trauma exposure and posttraumatic stress disorder (PTSD) symptoms for children consistent with the DSM-5 definition of PTSD. Study 1 describes measure development incorporating analysis to derive items based on existing measures from 1,065 children and caregivers together with stakeholder input to finalize item selection. Study 2 describes validation of the CTS with a clinical sample of 74 children and their caregivers. Results support the CTS as an empirically derived, reliable measure to screen children for trauma exposure and PTSD symptoms with strong convergent, divergent, and criterion validity. The CTS is a promising measure for rapidly and reliably screening children for trauma exposure and PTSD symptoms. Future research is needed to confirm validation and to examine feasibility and utility of its use across various child-serving systems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Estimating the effect of gestational age on test performance of combined first-trimester screening for Down syndrome: a preliminary study.

    PubMed

    van Heesch, Peter N; Struijk, Pieter C; Laudy, Jaqueline A M; Steegers, Eric A P; Wildschut, Hajo I J

    2010-05-01

    To establish how different methods of estimating gestational age (GA) affect reliability of first-trimester screening for Down syndrome. Retrospective single-center study of 100 women with a viable singleton pregnancy, who had first-trimester screening. We calculated multiples of the median (MoM) for maternal-serum free beta human chorionic gonadotropin (free beta-hCG) and pregnancy associated plasma protein-A (PAPP-A), derived from either last menstrual period (LMP) or ultrasound-dating scans. In women with a regular cycle, LMP-derived estimates of GA were two days longer (range -11 to 18), than crown-rump length (CRL)-derived estimates of GA whereas this discrepancy was more pronounced in women who reported to have an irregular cycle, i.e., six days (range -7 to 32). Except for PAPP-A in the regular-cycle group, all differences were significant. Consequently, risk estimates are affected by the mode of estimating GA. In fact, LMP-based estimates revealed ten "screen-positive" cases compared to five "screen-positive" cases where GA was derived from dating-scans. Provided fixed values for nuchal translucency are applied, dating-scans reduce the number of screen-positive findings on the basis of biochemical screening. We recommend implementation of guidelines for Down syndrome screening based on CRL-dependent rather than LMP-dependent parameters of GA.

  20. How reliable are Functional Movement Screening scores? A systematic review of rater reliability.

    PubMed

    Moran, Robert W; Schneiders, Anthony G; Major, Katherine M; Sullivan, S John

    2016-05-01

    Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Systematic literature review. Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. 12 studies were appraised. Overall, there was a 'moderate' level of evidence in favour of 'acceptable' (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was 'conflicting' evidence, and 'limited' evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was 'moderate' evidence of 'acceptable' reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and 'conflicting' evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). This review found 'moderate' evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to rater blinding. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Methods of Measurement in epidemiology: Sedentary Behaviour

    PubMed Central

    Atkin, Andrew J; Gorely, Trish; Clemes, Stacy A; Yates, Thomas; Edwardson, Charlotte; Brage, Soren; Salmon, Jo; Marshall, Simon J; Biddle, Stuart JH

    2012-01-01

    Background Research examining sedentary behaviour as a potentially independent risk factor for chronic disease morbidity and mortality has expanded rapidly in recent years. Methods We present a narrative overview of the sedentary behaviour measurement literature. Subjective and objective methods of measuring sedentary behaviour suitable for use in population-based research with children and adults are examined. The validity and reliability of each method is considered, gaps in the literature specific to each method identified and potential future directions discussed. Results To date, subjective approaches to sedentary behaviour measurement, e.g. questionnaires, have focused predominantly on TV viewing or other screen-based behaviours. Typically, such measures demonstrate moderate reliability but slight to moderate validity. Accelerometry is increasingly being used for sedentary behaviour assessments; this approach overcomes some of the limitations of subjective methods, but detection of specific postures and postural changes by this method is somewhat limited. Instruments developed specifically for the assessment of body posture have demonstrated good reliability and validity in the limited research conducted to date. Miniaturization of monitoring devices, interoperability between measurement and communication technologies and advanced analytical approaches are potential avenues for future developments in this field. Conclusions High-quality measurement is essential in all elements of sedentary behaviour epidemiology, from determining associations with health outcomes to the development and evaluation of behaviour change interventions. Sedentary behaviour measurement remains relatively under-developed, although new instruments, both objective and subjective, show considerable promise and warrant further testing. PMID:23045206

  2. Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson’s disease

    PubMed Central

    Nackaerts, Evelien; Heremans, Elke; Smits-Engelsman, Bouwien C. M.; Broeder, Sanne; Vandenberghe, Wim; Bergmans, Bruno; Nieuwboer, Alice

    2017-01-01

    Background Handwriting in Parkinson’s disease (PD) features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available. Objective This study aims to validate the ‘Systematic Screening of Handwriting Difficulties’ (SOS-test) in patients with PD. Methods Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes), size (mm) and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Spearman correlation coefficient. Results Patients with PD had a smaller (p = 0.043) and slower (p<0.001) handwriting and showed worse writing quality (p = 0.031) compared to controls. The outcomes of the SOS-test significantly correlated with fine motor skill performance and disease duration and severity. Furthermore, the test showed excellent intrarater, interrater and test-retest reliability (ICC > 0.769 for both groups). Conclusion The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD. PMID:28253374

  3. A high-throughput multiplex method adapted for GMO detection.

    PubMed

    Chaouachi, Maher; Chupeau, Gaëlle; Berard, Aurélie; McKhann, Heather; Romaniuk, Marcel; Giancola, Sandra; Laval, Valérie; Bertheau, Yves; Brunel, Dominique

    2008-12-24

    A high-throughput multiplex assay for the detection of genetically modified organisms (GMO) was developed on the basis of the existing SNPlex method designed for SNP genotyping. This SNPlex assay allows the simultaneous detection of up to 48 short DNA sequences (approximately 70 bp; "signature sequences") from taxa endogenous reference genes, from GMO constructions, screening targets, construct-specific, and event-specific targets, and finally from donor organisms. This assay avoids certain shortcomings of multiplex PCR-based methods already in widespread use for GMO detection. The assay demonstrated high specificity and sensitivity. The results suggest that this assay is reliable, flexible, and cost- and time-effective for high-throughput GMO detection.

  4. The use of the 2-aminobenzoic acid tag for oligosaccharide gel electrophoresis.

    PubMed

    Huang, Z; Prickett, T; Potts, M; Helm, R F

    2000-08-18

    Gel electrophoresis of fluorophore labeled saccharides provides a rapid and reliable method to screen enzymatic and/or chemical treatments of polysaccharides and glycoconjugates, as well as a sensitive and efficient microscale method to separate and purify oligosaccharides for further analysis. A simple and inexpensive method of derivatization and analysis using 2-aminobenzoic acid (anthranilic acid, AA) is described and applied to the extracellular polysaccharide released by the desiccation tolerant cyanobacterium Nostoc commune DRH-1. The results of these analyses suggest a possible protective functionality of two pendent groups, as well as a potential relationship between these groups and the desiccation tolerance of the organism.

  5. Inter- and intra-observer reliability of clinical movement-control tests for marines

    PubMed Central

    2012-01-01

    Background Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel. Methods This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed an in-vivo observation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model. Results Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain. Conclusions Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain. PMID:23273285

  6. Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.

    PubMed

    Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun

    2018-05-14

    To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.

  7. Screening for Autism in Young Children with Developmental Delay: An Evaluation of the Developmental Behaviour Checklist--Early Screen

    ERIC Educational Resources Information Center

    Gray, K. M.; Tonge, B. J.; Sweeney, D. J.; Einfeld, S. L.

    2008-01-01

    The ability to identify children who require specialist assessment for the possibility of autism at as early an age as possible has become a growing area of research. A number of measures have been developed as potential screening tools for autism. The reliability and validity of one of these measures for screening for autism in young children…

  8. The reliability and validity of measurements of human dental casts made by an intra-oral 3D scanner, with conventional hand-held digital callipers as the comparison measure.

    PubMed

    Rajshekar, Mithun; Julian, Roberta; Williams, Anne-Marie; Tennant, Marc; Forrest, Alex; Walsh, Laurence J; Wilson, Gary; Blizzard, Leigh

    2017-09-01

    Intra-oral 3D scanning of dentitions has the potential to provide a fast, accurate and non-invasive method of recording dental information. The aim of this study was to assess the reliability of measurements of human dental casts made using a portable intra-oral 3D scanner appropriate for field use. Two examiners each measured 84 tooth and 26 arch features of 50 sets of upper and lower human dental casts using digital hand-held callipers, and secondly using the measuring tool provided with the Zfx IntraScan intraoral 3D scanner applied to the virtual dental casts. The measurements were repeated at least one week later. Reliability and validity were quantified concurrently by calculation of intra-class correlation coefficients (ICC) and standard errors of measurement (SEM). The measurements of the 110 landmark features of human dental casts made using the intra-oral 3D scanner were virtually indistinguishable from measurements of the same features made using conventional hand-held callipers. The difference of means as a percentage of the average of the measurements by each method ranged between 0.030% and 1.134%. The intermethod SEMs ranged between 0.037% and 0.535%, and the inter-method ICCs ranged between 0.904 and 0.999, for both the upper and the lower arches. The inter-rater SEMs were one-half and the intra-method/rater SEMs were one-third of the inter-method values. This study demonstrates that the Zfx IntraScan intra-oral 3D scanner with its virtual on-screen measuring tool is a reliable and valid method for measuring the key features of dental casts. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Sandwich ELISA Microarrays: Generating Reliable and Reproducible Assays for High-Throughput Screens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, Rachel M.; Varnum, Susan M.; Zangar, Richard C.

    The sandwich ELISA microarray is a powerful screening tool in biomarker discovery and validation due to its ability to simultaneously probe for multiple proteins in a miniaturized assay. The technical challenges of generating and processing the arrays are numerous. However, careful attention to possible pitfalls in the development of your antibody microarray assay can overcome these challenges. In this chapter, we describe in detail the steps that are involved in generating a reliable and reproducible sandwich ELISA microarray assay.

  10. FNAC: its role, limitations and perspective in the preoperative diagnosis of breast cancer.

    PubMed

    Zagorianakou, P; Fiaccavento, S; Zagorianakou, N; Makrydimas, G; Stefanou, D; Agnantis, N J

    2005-01-01

    Fine-needle aspiration cytology (FNAC) was first described and performed in 1930. Thirty years later, it gained acceptance first in Europe and about a decade later in North America. The method is generally considered as a rapid, reliable, safe diagnostic tool to distinguish non-neoplastic from neoplastic breast lesions. In developed countries, in the last 20 years, mammographic screening programmes, which have been used extensively, are designed to detect the earliest possible breast cancer. The FNAC report is extremely important because it gives the necessary information for the management of patients, in order to proceed with more invasive diagnostic methods or surgical treatment, and to decide what kind of operation to perform. In the preoperative phase, FNAC has taken a fundamental role of both palpable and nonpalpable lesions, using ultrasound or stereotactic guidance. New developed techniques, breast biopsy instrumentation (ABBI) and mammotome have the advantage of complete removal of breast lesions, but this is not possible in all the examined cases. In developing countries, economical restrictions, low budget for health care and screening programmes put the patients at a disadvantage because of the high cost of sophisticated diagnostic methods, thus we recommend that FNAC be used as a routine diagnostic method because of its low cost compared with the others and this policy maximizes the availability of health care to women with breast cancer. We conclude that FNAC plays an important and essential role in the management of patients with breast lesions and also offers a great potential for prediction of patient outcome, disease response to therapy and assessment of risk of developing breast cancer. The reliability and efficiency of the method depends on the quality of the samples and the experience of the medical staff that performs the aspiration.

  11. Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening.

    PubMed

    Seoud, Lama; Hurtut, Thomas; Chelbi, Jihed; Cheriet, Farida; Langlois, J M Pierre

    2016-04-01

    The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and validated. The main contribution is a new set of shape features, called Dynamic Shape Features, that do not require precise segmentation of the regions to be classified. These features represent the evolution of the shape during image flooding and allow to discriminate between lesions and vessel segments. The method is validated per-lesion and per-image using six databases, four of which are publicly available. It proves to be robust with respect to variability in image resolution, quality and acquisition system. On the Retinopathy Online Challenge's database, the method achieves a FROC score of 0.420 which ranks it fourth. On the Messidor database, when detecting images with diabetic retinopathy, the proposed method achieves an area under the ROC curve of 0.899, comparable to the score of human experts, and it outperforms state-of-the-art approaches.

  12. A Computational Methodology to Screen Activities of Enzyme Variants

    PubMed Central

    Hediger, Martin R.; De Vico, Luca; Svendsen, Allan; Besenmatter, Werner; Jensen, Jan H.

    2012-01-01

    We present a fast computational method to efficiently screen enzyme activity. In the presented method, the effect of mutations on the barrier height of an enzyme-catalysed reaction can be computed within 24 hours on roughly 10 processors. The methodology is based on the PM6 and MOZYME methods as implemented in MOPAC2009, and is tested on the first step of the amide hydrolysis reaction catalyzed by the Candida Antarctica lipase B (CalB) enzyme. The barrier heights are estimated using adiabatic mapping and shown to give barrier heights to within 3 kcal/mol of B3LYP/6-31G(d)//RHF/3-21G results for a small model system. Relatively strict convergence criteria (0.5 kcal/(molÅ)), long NDDO cutoff distances within the MOZYME method (15 Å) and single point evaluations using conventional PM6 are needed for reliable results. The generation of mutant structures and subsequent setup of the semiempirical calculations are automated so that the effect on barrier heights can be estimated for hundreds of mutants in a matter of weeks using high performance computing. PMID:23284627

  13. Establishment of A431 cell membrane chromatography-RPLC method for screening target components from Radix Caulophylli.

    PubMed

    Hou, Xiaofang; Wang, Sicen; Hou, Jingjing; He, Langchong

    2011-03-01

    We describe here an analytical method of A431 cell membrane chromatography (A431/CMC) (CMC, cell membrane chromatography) combined with RPLC for recognition, separation, and identification of target components from traditional Chinese medicines (TCMs) Radix Caulophylli. The A431 cells with high expressed epidermal growth factor receptor (EGFR) were used to prepare the stationary phase in the CMC model. Retention fractions on the A431-CMC model were collected using an automated fraction collection and injection module (FC/I). Each fraction was analyzed by RPLC under the optimized conditions. Gefitinib and erlotinib were used as standard compounds to investigate the suitability and reliability of the A431 cell membrane chromatography-RPLC method prior to screening target component from Radix Caulophylli total alkaloids. The results indicated that caulophine and taspine were the target component acting on the epidermal growth factor receptor. This method could be an efficient way in drug discovery using natural medicinal herbs as a source of novel compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Preschool Developmental Screening with Denver II Test in Semi-Urban Areas

    ERIC Educational Resources Information Center

    Eratay, Emine; Bayoglu, Birgül; Anlar, Banu

    2015-01-01

    Purpose: To assess the feasibility and reliability of screening semi-urban preschool children with Denver II, developmental and neurological status was examined in relation with one-year outcome. Methodology: Denver II developmental screening test was applied to 583 children who visited family physicians or other health centers in a province of…

  15. A Psychometric Study of the Substance Abuse Subtle Screening Inventory-3 Using Rasch Analysis

    ERIC Educational Resources Information Center

    Hill, Tara M.

    2009-01-01

    The Substance Abuse Subtle Screening Inventory-3 (SASSI-3; Miller & Lazowski, 1999) is a popular screening instrument used to assist professionals in the assessment of individuals who may be substance dependent. Many researchers have reported reliability and validity results on this instrument with mixed results, which at times have…

  16. Mathematics Screening: The Development and Pilot Study of a Mathematics Screening Instrument for K-2 Grades

    ERIC Educational Resources Information Center

    Anderson, Stephen A.

    2010-01-01

    This paper summarizes an action research project to develop a math screening instrument that would be effective (valid and reliable) and efficient (time for administration). An instrument was developed after review of the mathematics assessment and mathematics disabilities literature. The instrument was administered to kindergarten, first, and…

  17. Can Screening and Confirmatory Testing in the Management of Patients with Primary Aldosteronism be Improved?

    PubMed

    Stowasser, Michael; Ahmed, Ashraf; Guo, Zeng; Wolley, Martin; Ungerer, Jacobus; McWhinney, Brett; Poglitsch, Marko; Gordon, Richard

    2017-12-01

    Widespread application of the plasma aldosterone/renin ratio (ARR) as a screening test has led to the recognition that primary aldosteronism (PA) is the most common specifically treatable and potentially curable form of hypertension, accounting for 5-10% of patients. Maximal detection requires accurate diagnostic approaches and awareness and control of factors that confound results, including most antihypertensives, posture, time of day, dietary salt, and plasma potassium. Recent studies have revealed potential for false positives in patients on beta-adrenoceptor blockers, and, when direct renin concentration (but not plasma renin activity) is used to measure renin, in women during the luteal phase of the menstrual cycle or receiving estrogen-containing contraceptives or hormonal replacement therapy. In addition to verapamil slow release, hydralazine and prazosin, moxonidine has minimal effects on the ARR and can be used to control hypertension during work-up. Fludrocortisone suppression testing, while probably the most reliable means of definitively confirming or excluding PA, is time consuming and expensive, requiring a five day inpatient stay. A novel approach, upright (seated) saline infusion suppression testing (SST), has shown excellent reliability with much greater sensitivity than conventional recumbent SST in a recent pilot study, and requires only a day visit. Accurate measurement of aldosterone is essential for each step of PA workup: introduction of new, highly reliable high-throughput mass spectrometric methods into clinical practice has represented a major advance. In response to concerns raised about accuracy of renin assays, new mass spectrometric methods for measuring angiotensin II are currently being assessed in the clinical setting. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Breast cancer and screening information needs and preferred communication medium among Iranian immigrant women in Toronto.

    PubMed

    Vahabi, Mandana

    2011-11-01

    Few studies have investigated what information women from minority immigrant groups need about breast cancer and screening. Nor has much research been conducted about how such women would prefer to receive this information. Mere translation of breast cancer and screening information from generic materials, without considering and respecting women's unique historical, political, and cultural experiences, is insufficient. This study explored breast cancer and screening information needs and preferred methods of communication among Iranian immigrant women. A convenience sample of 50 women was recruited and interviewed over a 4-month period (June-September 2008); all resided in Toronto Canada, and had no history of breast cancer. Tape-recorded interviews were transcribed and analysed using a thematic analysis technique. While generic breast health communication focusing on physiological risk information meets some of the needs of Iranian immigrant women, results showed that the needs of this group go beyond this basic information. This group is influenced by historical, sociopolitical, and cultural experiences pre- and post-immigration. Their experiences with chemical war, unsafe physical environment (air and water pollution), and their sociopolitical situation appear to have limited their access to accurate and reliable breast cancer and screening information in their homeland. Moreover, the behavioural and psychosocial changes they face after immigration appear to have a strong influence on their breast cancer and screening information needs. Considering their limited time due to their multiple demands post-migration, multi-media methods were highly preferred as a communication means by this group. The results of this study can be used to guide the design and implementation of culturally sensitive breast health information. For instance, video presentations conducted by a trusted Iranian healthcare professional focusing on socioculturally relevant breast cancer risk factors, symptoms, and screening methods, as well as a list of available breast health resources, could improve Iranian women's knowledge and uptake of breast health practices. © 2011 Blackwell Publishing Ltd.

  19. Comparison of simple screening criteria with the International Caries Detection and Assessment System classification in determining restorative treatment need.

    PubMed

    Kämppi, Antti; Tanner, Tarja; Päkkilä, Jari; Patinen, Pertti; Tjäderhane, Leo; Anttonen, Vuokko

    2016-04-01

    The Finnish Defence Forces' unique oral health-screening protocol (FDFsp) has been in use for decades. In FDFsp, restorative treatment need is determined based on the World Health Organization (WHO) criteria. The aim of this study was to compare the outcome of screening restorative treatment need with the outcome of using the International Caries Detection and Assessment System (ICDAS) classification at both individual and tooth levels. Our hypothesis was that the outcome of screening with FDFsp agrees with the outcome of using the ICDAS classification. In this study, a trained, calibrated examiner estimated, in a visual-tactile manner the restorative treatment need of 337 young healthy adults using the FDFsp. During the screening, 74 conscripts were selected for a thorough inspection. The inclusion criteria for those selected were: having no, having one to five, or having six or more caries lesions needing restorative treatment. In the thorough inspection, the participants were inspected in a visual-tactile manner using the ICDAS classification. The association of the outcomes achieved using the two different methods was analysed at individual and tooth levels. Sensitivity, specificity, and kappa values were calculated. Wisdom teeth were excluded. At the individual level, the agreement between the outcomes of using FDFsp and ICDAS ≥4 was excellent: sensitivity, 94.1%; specificity, 97.5%; and kappa = 0.92. When ICDAS ≥3 was used, the values were 72.7%, 96.7%, and 0.66%, respectively. Screening performed by a trained examiner using specific criteria is a reliable method for detecting individuals with restorative treatment need. The outcome of screening agrees strongly with results using the ICDAS classification. © 2015 FDI World Dental Federation.

  20. Review of the Potential of the Ni/Cu Plating Technique for Crystalline Silicon Solar Cells

    PubMed Central

    Rehman, Atteq ur; Lee, Soo Hong

    2014-01-01

    Developing a better method for the metallization of silicon solar cells is integral part of realizing superior efficiency. Currently, contact realization using screen printing is the leading technology in the silicon based photovoltaic industry, as it is simple and fast. However, the problem with metallization of this kind is that it has a lower aspect ratio and higher contact resistance, which limits solar cell efficiency. The mounting cost of silver pastes and decreasing silicon wafer thicknesses encourages silicon solar cell manufacturers to develop fresh metallization techniques involving a lower quantity of silver usage and not relying pressing process of screen printing. In recent times nickel/copper (Ni/Cu) based metal plating has emerged as a metallization method that may solve these issues. This paper offers a detailed review and understanding of a Ni/Cu based plating technique for silicon solar cells. The formation of a Ni seed layer by adopting various deposition techniques and a Cu conducting layer using a light induced plating (LIP) process are appraised. Unlike screen-printed metallization, a step involving patterning is crucial for opening the masking layer. Consequently, experimental procedures involving patterning methods are also explicated. Lastly, the issues of adhesion, back ground plating, process complexity and reliability for industrial applications are also addressed. PMID:28788516

  1. Review of the Potential of the Ni/Cu Plating Technique for Crystalline Silicon Solar Cells.

    PubMed

    Rehman, Atteq Ur; Lee, Soo Hong

    2014-02-18

    Developing a better method for the metallization of silicon solar cells is integral part of realizing superior efficiency. Currently, contact realization using screen printing is the leading technology in the silicon based photovoltaic industry, as it is simple and fast. However, the problem with metallization of this kind is that it has a lower aspect ratio and higher contact resistance, which limits solar cell efficiency. The mounting cost of silver pastes and decreasing silicon wafer thicknesses encourages silicon solar cell manufacturers to develop fresh metallization techniques involving a lower quantity of silver usage and not relying pressing process of screen printing. In recent times nickel/copper (Ni/Cu) based metal plating has emerged as a metallization method that may solve these issues. This paper offers a detailed review and understanding of a Ni/Cu based plating technique for silicon solar cells. The formation of a Ni seed layer by adopting various deposition techniques and a Cu conducting layer using a light induced plating (LIP) process are appraised. Unlike screen-printed metallization, a step involving patterning is crucial for opening the masking layer. Consequently, experimental procedures involving patterning methods are also explicated. Lastly, the issues of adhesion, back ground plating, process complexity and reliability for industrial applications are also addressed.

  2. Analysis of SNP rs16754 of WT1 gene in a series of de novo acute myeloid leukemia patients.

    PubMed

    Luna, Irene; Such, Esperanza; Cervera, Jose; Barragán, Eva; Jiménez-Velasco, Antonio; Dolz, Sandra; Ibáñez, Mariam; Gómez-Seguí, Inés; López-Pavía, María; Llop, Marta; Fuster, Óscar; Oltra, Silvestre; Moscardó, Federico; Martínez-Cuadrón, David; Senent, M Leonor; Gascón, Adriana; Montesinos, Pau; Martín, Guillermo; Bolufer, Pascual; Sanz, Miguel A

    2012-12-01

    The single nucleotide polymorphism (SNP) rs16754 of the WT1 gene has been previously described as a possible prognostic marker in normal karyotype acute myeloid leukemia (AML) patients. Nevertheless, the findings in this field are not always reproducible in different series. One hundred and seventy-five adult de novo AML patients were screened with two different methods for the detection of SNP rs16754: high-resolution melting (HRM) and FRET hybridization probes. Direct sequencing was used to validate both techniques. The SNP was detected in 52 out of 175 patients (30 %), both by HRM and hybridization probes. Direct sequencing confirmed that every positive sample in the screening methods had a variation in the DNA sequence. Patients with the wild-type genotype (WT1(AA)) for the SNP rs16754 were significantly younger than those with the heterozygous WT1(AG) genotype. No other difference was observed for baseline characteristic or outcome between patients with or without the SNP. Both techniques are equally reliable and reproducible as screening methods for the detection of the SNP rs16754, allowing for the selection of those samples that will need to be sequenced. We were unable to confirm the suggested favorable outcome of SNP rs16754 in de novo AML.

  3. The use of high resolution melting analysis to detect Fabry mutations in heterozygous females via dry bloodspots.

    PubMed

    Tai, Chang-Long; Liu, Mei-Ying; Yu, Hsiao-Chi; Chiang, Chiang-Chuan; Chiang, Hung; Suen, Jeng-Hung; Kao, Shu-Min; Huang, Yu-Hsiu; Wu, Tina Jui-Ting; Yang, Chia-Feng; Tsai, Fang-Chih; Lin, Ching-Yuang; Chang, Jan-Gowth; Chen, Hong-Duo; Niu, Dau-Ming

    2012-02-18

    As an X-linked genetic disorder, Fabry disease was first thought to affect males only, and females were generally considered to be asymptomatic carriers. However, recent research suggests that female carriers of Fabry disease may still develop vital organ damage causing severe morbidity and mortality. In the previous newborn screening, from 299,007 newborns, we identified a total of 20 different Fabry mutations and 121 newborns with Fabry mutations. However, we found that most female carriers are not detected by enzyme assays. A streamlined method for high resolution melting (HRM) analysis was designed to screen for GLA gene mutations using a same PCR and melting program. Primer sets were designed to cover the 7 exons and the Chinese common intronic mutation, IVS4+919G>A of GLA gene. The HRM analysis was successful in identifying heterozygous and hemizygous patients with the 20 surveyed mutations. We were also successful in using this method to test dry blood spots of newborns afflicted with Fabry mutations without having to determine DNA concentration before PCR amplification. The results of this study show that HRM could be a reliable and sensitive method for use in the rapid screening of females for GLA mutations. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Single-step colony assay for screening antibody libraries.

    PubMed

    Kato, Mieko; Hanyu, Yoshiro

    2017-08-10

    We describe a method, single-step colony assay, for simple and rapid screening of single-chain Fv fragment (scFv) libraries. Colonies of Escherichia coli expressing the scFv library are formed on a hydrophilic filter that is positioned in contact with a membrane coated with an antigen. scFv expression is triggered upon treatment of colonies with an induction reagent, following which scFvs are secreted from the cells and diffused to the antigen-coated membrane. scFvs that exhibit binding affinity for the antigen are captured by the membrane-immobilized antigen. Lastly, detection of scFv binding of the antigen on the membrane allows identification of the clones on the filter that express antigen-specific scFvs. We tested this methodology by using an anti-rabbit IgG scFv, scFv(A10B), and a rat immune scFv library. Experiments conducted using scFv(A10B) revealed that this method improves scFv expression during the colony assay. By using our method to screen an immune library of 3×10 3 scFv clones, we established several clones exhibiting affinity for the antigen. Moreover, we tested 7 other antigens, including peptides, and successfully identified positive clones. We believe that this simple procedure and controlled scFv expression of the single-step colony assay could make the antibody screening both rapid and reliable and lead to successful isolation of positive clones from antibody libraries. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Screening tests for aphasia in patients with stroke: a systematic review.

    PubMed

    El Hachioui, Hanane; Visch-Brink, Evy G; de Lau, Lonneke M L; van de Sandt-Koenderman, Mieke W M E; Nouwens, Femke; Koudstaal, Peter J; Dippel, Diederik W J

    2017-02-01

    Aphasia has a large impact on the quality of life and adds significantly to the costs of stroke care. Early recognition of aphasia in stroke patients is important for prognostication and well-timed treatment planning. We aimed to identify available screening tests for differentiating between aphasic and non-aphasic stroke patients, and to evaluate test accuracy, reliability, and feasibility. We searched PubMed, EMbase, Web of Science, and PsycINFO for published studies on screening tests aimed at assessing aphasia in stroke patients. The reference lists of the selected articles were scanned, and several experts were contacted to detect additional references. Of each screening test, we estimated the sensitivity, specificity, likelihood ratio of a positive test, likelihood ratio of a negative test, and diagnostic odds ratio (DOR), and rated the degree of bias of the validation method. We included ten studies evaluating eight screening tests. There was a large variation across studies regarding sample size, patient characteristics, and reference tests used for validation. Many papers failed to report on the consecutiveness of patient inclusion, time between aphasia onset and administration of the screening test, and blinding. Of the three studies that were rated as having an intermediate or low risk of bias, the DOR was highest for the Language Screening Test and ScreeLing. Several screening tools for aphasia in stroke are available, but many tests have not been verified properly. Methodologically sound validation studies of aphasia screening tests are needed to determine their usefulness in clinical practice.

  6. Refining a questionnaire to assess breast cancer knowledge and barriers to screening in Kenya: Psychometric assessment of the BCAM.

    PubMed

    Wachira, J; Busakhala, A; Chite, F; Naanyu, V; Kisuya, J; Otieno, G; Keter, A; Mwangi, A; Inui, T

    2017-02-03

    Our study objective was to determine the validity and reliability of the breast module of a cancer awareness measure (BCAM) among adult women in western Kenya. The study was conducted between October and November 2012, following three breast cancer screening events. Purposive and systematic random sampling methods were used to identity 48 women for cognitive focus group discussions, and 1061 (594 who attended vs. 467 who did not attend screening events) for surveys, respectively. Face and psychometric validity of the BCAM survey was assessed using cognitive testing, factor analysis of survey data, and correlations. Internal reliability was assessed using Cronbach's alpha. Among survey participants, the overall median age was 34 (IQR: 26-44) years. Compared to those women who did not attend the screening events, women attendees were older (median: 35 vs. 32 years, p = 0.001) more often married (79% vs. 72%, p = 0.006), more educated (52% vs. 46% with more than an elementary level of education, p = 0.001), more unemployed (59% vs. 11%, p = 0.001), more likely to report doing breast self-examination (56% vs. 40%, p = 0.001) and more likely to report having felt a breast lump (16% vs. 7%, p = 0.001). For domain 1 on knowledge of breast cancer symptoms, one factor (three items) with Eigen value of 1.76 emerged for the group that did not attend screening, and 1.50 for the group that attended screening. For both groups two factors (factor 1 "internal influences" and factor 2 "external influences") emerged among domain 4 on barriers to screening, with varied item loadings and Eigen values. There were no statistically significant differences in the factor scores between attendees and non-attendees. There were significant associations between factor scores and other attributes of the surveyed population, including associations with occupation, transportation type, and training for and practice of breast self-examination. Cronbach's alpha showed an acceptable internal consistency. Certain subpopulations are less likely than others to attend breast screening in Kenya. A survey measure of breast cancer knowledge and perceived barriers to screening shows promise for use in Kenya for characterizing clinical and community population beliefs, but needs adaptation for setting, language and culture.

  7. Auditory-steady-state response reliability in the audiological diagnosis after neonatal hearing screening.

    PubMed

    Núñez-Batalla, Faustino; Noriega-Iglesias, Sabel; Guntín-García, Maite; Carro-Fernández, Pilar; Llorente-Pendás, José Luis

    2016-01-01

    Conventional audiometry is the gold standard for quantifying and describing hearing loss. Alternative methods become necessary to assess subjects who are too young to respond reliably. Auditory evoked potentials constitute the most widely used method for determining hearing thresholds objectively; however, this stimulus is not frequency specific. The advent of the auditory steady-state response (ASSR) leads to more specific threshold determination. The current study describes and compares ASSR, auditory brainstem response (ABR) and conventional behavioural tone audiometry thresholds in a group of infants with various degrees of hearing loss. A comparison was made between ASSR, ABR and behavioural hearing thresholds in 35 infants detected in the neonatal hearing screening program. Mean difference scores (±SD) between ABR and high frequency ABR thresholds were 11.2 dB (±13) and 10.2 dB (±11). Pearson correlations between the ASSR and audiometry thresholds were 0.80 and 0.91 (500Hz); 0.84 and 0.82 (1000Hz); 0.85 and 0.84 (2000Hz); and 0.83 and 0.82 (4000Hz). The ASSR technique is a valuable extension of the clinical test battery for hearing-impaired children. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  8. High-throughput screening for thermoelectric sulphides by using crystal structure features as descriptors

    NASA Astrophysics Data System (ADS)

    Zhang, Ruizhi; Du, Baoli; Chen, Kan; Reece, Mike; Materials Research Insititute Team

    With the increasing computational power and reliable databases, high-throughput screening is playing a more and more important role in the search of new thermoelectric materials. Rather than the well established density functional theory (DFT) calculation based methods, we propose an alternative approach to screen for new TE materials: using crystal structural features as 'descriptors'. We show that a non-distorted transition metal sulphide polyhedral network can be a good descriptor for high power factor according to crystal filed theory. By using Cu/S containing compounds as an example, 1600+ Cu/S containing entries in the Inorganic Crystal Structure Database (ICSD) were screened, and of those 84 phases are identified as promising thermoelectric materials. The screening results are validated by both electronic structure calculations and experimental results from the literature. We also fabricated some new compounds to test our screening results. Another advantage of using crystal structure features as descriptors is that we can easily establish structural relationships between the identified phases. Based on this, two material design approaches are discussed: 1) High-pressure synthesis of metastable phase; 2) In-situ 2-phase composites with coherent interface. This work was supported by a Marie Curie International Incoming Fellowship of the European Community Human Potential Program.

  9. Assessment of the structural validity of the domestic violence healthcare providers’ survey questionnaire using a Nigerian sample

    PubMed Central

    John, Ime A; Lawoko, Stephen

    2010-01-01

    Abstract: Background: There has been increased advocacy to involve healthcare providers in the prevention of intimate partner violence (IPV) through screening for it in healthcare. Yet, only one in ten providers screen for IPV, suggesting barriers. Understanding the readiness of healthcare providers to screen for IPV is therefore paramount. The Domestic Violence Healthcare Provider Survey Scales (DVHPSS) is a previously validated, comprehensive scale to study readiness of healthcare providers to screen for IPV. However, an understanding of its usefulness in the Sub-Saharan African context remains elusive. The current study undertook to examine the structural validity of the DVHPSS in Nigeria. Methods: Exploratory factor analysis and Cronbach's Alpha were run to reveal the factorial structure and reliability of the instrument/subscales respectively. Established thresholds were used to determine significant factor loadings and alphas coefficient. Results: A six factor model emerged, with 2 factors similar to the original scale, another two differing slightly and a further two factors resulting from a splitting up of the original combination of victim/provider safety to having distinct victim and provider safety subscales. Conclusions: With slight modifications, the DVHPSS can be use to study IPV screening among Nigerian healthcare professionals. Introducing screening protocols could promote better understanding of crucial questions that were lost in the analysis. PMID:21483202

  10. Development of a Computer-Based Survey Instrument for Organophosphate and N-Methyl-Carbamate Exposure Assessment among Agricultural Pesticide Handlers

    PubMed Central

    Hofmann, Jonathan N.; Checkoway, Harvey; Borges, Ofelio; Servin, Flor; Fenske, Richard A.; Keifer, Matthew C.

    2010-01-01

    Background: Assessment of occupational pesticide exposures based on self-reported information can be challenging, particularly with immigrant farm worker populations for whom specialized methods are needed to address language and cultural barriers and account for limited literacy. An audio computer-assisted self-interview (A-CASI) survey instrument was developed to collect information about organophosphate (OP) and N-methyl-carbamate (CB) exposures and other personal characteristics among male agricultural pesticide handlers for an ongoing cholinesterase biomonitoring study in Washington State. Objectives: To assess the feasibility of collecting data using the A-CASI instrument and evaluate reliability for a subset of survey items. Methods: The survey consisted of 64 items administered in Spanish or English on a touch-screen tablet computer. Participants listened to digitally recorded questions on headphones and selected responses on the screen, most of which were displayed as images or icons to facilitate participation of low literacy respondents. From 2006–2008, a total of 195 participants completed the survey during the OP/CB application seasons on at least one occasion. Percent agreement and kappa coefficients were calculated to evaluate test–retest reliability for selected characteristics among 45 participants who completed the survey on two separate occasions within the same year. Results: Almost all participants self-identified as Hispanic or Latino (98%), and 97% completed the survey in Spanish. Most participants completed the survey in a half-hour or less, with minimal assistance from on-site research staff. Analyses of test–retest reliability showed substantial agreement for most demographic, work history, and health characteristics and at least moderate agreement for most variables related to personal protective equipment use during pesticide applications. Conclusions: This A-CASI survey instrument is a novel method that has been used successfully to collect information about OP/CB exposures and other personal characteristics among Spanish-speaking agricultural pesticide handlers. PMID:20413416

  11. A screening method for the detection of the 35S promoter and the nopaline synthase terminator in genetically modified organisms in a real-time multiplex polymerase chain reaction using high-resolution melting-curve analysis.

    PubMed

    Akiyama, Hiroshi; Nakamura, Fumi; Yamada, Chihiro; Nakamura, Kosuke; Nakajima, Osamu; Kawakami, Hiroshi; Harikai, Naoki; Furui, Satoshi; Kitta, Kazumi; Teshima, Reiko

    2009-11-01

    To screen for unauthorized genetically modified organisms (GMO) in the various crops, we developed a multiplex real-time polymerase chain reaction high-resolution melting-curve analysis method for the simultaneous qualitative detection of 35S promoter sequence of cauliflower mosaic virus (35SP) and the nopaline synthase terminator (NOST) in several crops. We selected suitable primer sets for the simultaneous detection of 35SP and NOST and designed the primer set for the detection of spiked ColE1 plasmid to evaluate the validity of the polymerase chain reaction (PCR) analyses. In addition, we optimized the multiplex PCR conditions using the designed primer sets and EvaGreen as an intercalating dye. The contamination of unauthorized GMO with single copy similar to NK603 maize can be detected as low as 0.1% in a maize sample. Furthermore, we showed that the present method would be applicable in identifying GMO in various crops and foods like authorized GM soybean, authorized GM potato, the biscuit which is contaminated with GM soybeans and the rice which is contaminated with unauthorized GM rice. We consider this method to be a simple and reliable assay for screening for unauthorized GMO in crops and the processing food products.

  12. A Machine Learning Application Based in Random Forest for Integrating Mass Spectrometry-Based Metabolomic Data: A Simple Screening Method for Patients With Zika Virus.

    PubMed

    Melo, Carlos Fernando Odir Rodrigues; Navarro, Luiz Claudio; de Oliveira, Diogo Noin; Guerreiro, Tatiane Melina; Lima, Estela de Oliveira; Delafiori, Jeany; Dabaja, Mohamed Ziad; Ribeiro, Marta da Silva; de Menezes, Maico; Rodrigues, Rafael Gustavo Martins; Morishita, Karen Noda; Esteves, Cibele Zanardi; de Amorim, Aline Lopes Lucas; Aoyagui, Caroline Tiemi; Parise, Pierina Lorencini; Milanez, Guilherme Paier; do Nascimento, Gabriela Mansano; Ribas Freitas, André Ricardo; Angerami, Rodrigo; Costa, Fábio Trindade Maranhão; Arns, Clarice Weis; Resende, Mariangela Ribeiro; Amaral, Eliana; Junior, Renato Passini; Ribeiro-do-Valle, Carolina C; Milanez, Helaine; Moretti, Maria Luiza; Proenca-Modena, Jose Luiz; Avila, Sandra; Rocha, Anderson; Catharino, Rodrigo Ramos

    2018-01-01

    Recent Zika outbreaks in South America, accompanied by unexpectedly severe clinical complications have brought much interest in fast and reliable screening methods for ZIKV (Zika virus) identification. Reverse-transcriptase polymerase chain reaction (RT-PCR) is currently the method of choice to detect ZIKV in biological samples. This approach, nonetheless, demands a considerable amount of time and resources such as kits and reagents that, in endemic areas, may result in a substantial financial burden over affected individuals and health services veering away from RT-PCR analysis. This study presents a powerful combination of high-resolution mass spectrometry and a machine-learning prediction model for data analysis to assess the existence of ZIKV infection across a series of patients that bear similar symptomatic conditions, but not necessarily are infected with the disease. By using mass spectrometric data that are inputted with the developed decision-making algorithm, we were able to provide a set of features that work as a "fingerprint" for this specific pathophysiological condition, even after the acute phase of infection. Since both mass spectrometry and machine learning approaches are well-established and have largely utilized tools within their respective fields, this combination of methods emerges as a distinct alternative for clinical applications, providing a diagnostic screening-faster and more accurate-with improved cost-effectiveness when compared to existing technologies.

  13. A combined disc method with resazurin agar plate assay for early phenotypic screening of KPC, MBL and OXA-48 carbapenemases among Enterobacteriaceae.

    PubMed

    Teethaisong, Y; Eumkeb, G; Nakouti, I; Evans, K; Hobbs, G

    2016-08-01

    To validate a combined disc method along with resazurin chromogenic agar for early screening and differentiation of Klebsiella pneumoniae carbapenemase, metallo-β-lactamase and OXA-48 carbapenemase-producing Enterobacteriaceae. The combined disc test comprising of meropenem alone and with EDTA, phenylboronic acid or both EDTA and phenylboronic acid, and temocillin alone were evaluated with the resazurin chromogenic agar plate assay against a total of 86 molecularly confirmed Enterobacteriaceae clinical isolates (11 metallo-β-lactamases, eight Kl. pneumoniae carbapenemases, 11 OXA-48, 32 AmpC and 15 extended-spectrum-β-lactamase producers and nine co-producers of extended-spectrum-β-lactamase and AmpC). The inhibition zone diameters were measured and interpreted at 7 h for the presence of carbapenemase. All carbapenemase producers were phenotypically distinguished by this assay with 100% sensitivity and specificity. This early phenotypic method is very simple, inexpensive, and reliable in the detection and differentiation of carbapenemase-producing Enterobacteriaceae. It could be exploited in any microbiological laboratory for diagnosis of these recalcitrant bacteria. This assay poses excellent performance in discrimination of Kl. pneumoniae carbapenemase, metallo-β-lactamase and OXA-48 carbapenemases within 7 h, which is much faster than conventional disc diffusion methods. The rapid detection could help clinicians screen patients, control infection and provide epidemiological surveillance. © 2016 The Society for Applied Microbiology.

  14. The psychometric properties, sensitivity and specificity of the geriatric anxiety inventory, hospital anxiety and depression scale, and rating anxiety in dementia scale in aged care residents.

    PubMed

    Creighton, Alexandra S; Davison, Tanya E; Kissane, David W

    2018-02-22

    Limited research has been conducted into the identification of a valid and reliable screening measure for anxiety in aged care settings, despite it being one of the most common psychological conditions. This study aimed to determine an appropriate anxiety screening tool for aged care by comparing the reliability and validity of three commonly used measures and identifying specific cut-offs for the identification of generalized anxiety disorder (GAD). One-hundred and eighty nursing home residents (M age = 85.39 years) completed the GAI, HADS-A, and RAID, along with a structured diagnostic interview. Twenty participants (11.1%) met DSM-5 criteria for GAD. All measures had good psychometric properties , although reliability estimates for the HADS-A were sub-optimal. Privileging sensitivity , the GAI cut-off score of 9 gave sensitivity of 90.0% and specificity of 86.3%; HADS-A cut-off of 6 gave sensitivity of 90.0% and specificity of 80.6%; and RAID cut-off of 11 gave sensitivity of 85.0% and specificity of 72.5%. While all three measures had adequate reliability, validity, and cut-scores with high levels of sensitivity and specificity to detect anxiety within aged care, the GAI was the most consistently reliable and valid measure for screening for GAD.

  15. Spanish-language services assessment for children and adolescents (SACA): reliability of parent and adolescent reports.

    PubMed

    Bean, Donna L; Rotheram-Borus, Mary Jane; Leibowitz, Arleen; Horwitz, Sarah M; Weidmer, Beverly

    2003-02-01

    To assess test-retest reliability of the service utilization screening section of the Services Assessment for Children and Adolescents (SACA) interview among Spanish-speaking parents and adolescents, correspondence between parent and adolescent reports, and the correlation between reliability and participants' demographic and service use characteristics. The English SACA was translated and administered from September 1999 through January 2000 in Los Angeles County, California, on two separate occasions to eligible parents with a child (4-17 years old) who was a client of a local public mental health authority. Adolescents of these parents (12-17 years old) were also interviewed. Reliability was measured by the kappa statistic. Adult and adolescent reports about lifetime and previous year service setting use exhibited good reliability, but concordance of parents and adolescents did not. Children's service utilization appears to be correlated with reliability of parent reports, and child gender appears to be correlated with reliability of adolescent reports. The SACA appears to be a useful tool for screening Spanish-speaking families about child and adolescent mental health service use. These findings must be considered preliminary until replicated in a larger sample of culturally diverse Spanish-speaking families.

  16. Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.

    PubMed

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference.

  17. Point-of-Care Urine Tests for Smoking Status and Isoniazid Treatment Monitoring in Adult Patients

    PubMed Central

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Background Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. Methodology/Principal Findings 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. Conclusions IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference. PMID:23029310

  18. Nuchal translucency and first trimester risk assessment: a systematic review.

    PubMed

    Sheppard, Celeste; Platt, Lawrence D

    2007-06-01

    First-trimester risk assessment for fetal aneuploidy using nuchal translucency (NT) measurement is rapidly gaining popularity in the United States. In combination with maternal serum markers in the first trimester, the screening performance is exceptionally good, with detection rates of more than 80% at a screen positive rate of 5%. Recently, the method has been validated for screening for Down syndrome and other aneuploidies in multicenter trials in the United States and elsewhere. Compliance with established criteria for measurement of the NT is essential to achieve uniform reliability and high screening test sensitivity. There is an international consensus about the importance of specific training in the NT examination, conformity to standards of NT measurement, and regular audit for quality assurance. In the United States, the Nuchal Translucency Quality Review program has been developed to administer credentialing and quality review for registered practitioners. The Nuchal Translucency Quality Review credentials signify the proficiency of the sonographer or sonologist in NT measurement and participation in a regular quality assurance audit. We encourage accreditation of clinical sites offering first-trimester risk assessment to ensure the highest quality care.

  19. Measuring lip force by oral screens Part 2: The importance of screen design, instruction and suction.

    PubMed

    Wertsén, Madeleine; Stenberg, Manne

    2017-10-01

    The aim of this study was to find a reliable method for measuring lip force and to find the most important factors that influence the measurements in terms of magnitude and variability. The hypothesis tested was that suction is involved and thus the instruction and the design of the oral screen are of importance when measuring lip force. This is a methodological study in a healthy population. This study was conducted in a general community. The designs of the screens were soft and hard prefabricated screens and 2 semi-individually made with a tube allowing air to pass. The screens and the instructions squeeze or suck were tested on 29 healthy adults, one at a time and on 4 occasions. The test order of the screens was randomized. Data were collected during 4 consecutive days, and the procedure was repeated after 1 month. The participants were 29 healthy adult volunteers. The instruction was an important mean to distinguish between squeezing and sucking. The design of the screen affected the lip force so that it increases in relation to the projected area of the screen. A screen design with a tube allowing air to pass made it possible to avoid suction when squeezing. By measuring with and without allowing air to pass, it was possible to distinguish between suction related and not suction related lip force. The additional screen pressure when sucking was related to the ability to produce a negative intraoral pressure. In conclusion lip force increases in relation to the projected area of the screen, sucking generally increases the measured lip force and the additional screen pressure when sucking is related to the ability to produce a negative intraoral pressure.

  20. Can Touch Screen Tablets be Used to Assess Cognitive and Motor Skills in Early Years Primary School Children? A Cross-Cultural Study.

    PubMed

    Pitchford, Nicola J; Outhwaite, Laura A

    2016-01-01

    Assessment of cognitive and motor functions is fundamental for developmental and neuropsychological profiling. Assessments are usually conducted on an individual basis, with a trained examiner, using standardized paper and pencil tests, and can take up to an hour or more to complete, depending on the nature of the test. This makes traditional standardized assessments of child development largely unsuitable for use in low-income countries. Touch screen tablets afford the opportunity to assess cognitive functions in groups of participants, with untrained administrators, with precision recording of responses, thus automating the assessment process. In turn, this enables cognitive profiling to be conducted in contexts where access to qualified examiners and standardized assessments are rarely available. As such, touch screen assessments could provide a means of assessing child development in both low- and high-income countries, which would afford cross-cultural comparisons to be made with the same assessment tool. However, before touch screen tablet assessments can be used for cognitive profiling in low-to-high-income countries they need to be shown to provide reliable and valid measures of performance. We report the development of a new touch screen tablet assessment of basic cognitive and motor functions for use with early years primary school children in low- and high-income countries. Measures of spatial intelligence, visual attention, short-term memory, working memory, manual processing speed, and manual coordination are included as well as mathematical knowledge. To investigate if this new touch screen assessment tool can be used for cross-cultural comparisons we administered it to a sample of children ( N = 283) spanning standards 1-3 in a low-income country, Malawi, and a smaller sample of children ( N = 70) from first year of formal schooling from a high-income country, the UK. Split-half reliability, test-retest reliability, face validity, convergent construct validity, predictive criterion validity, and concurrent criterion validity were investigated. Results demonstrate "proof of concept" that touch screen tablet technology can provide reliable and valid psychometric measures of performance in the early years, highlighting its potential to be used in cross-cultural comparisons and research.

  1. Four Principles to Consider Before Advising Women on Screening Mammography.

    PubMed

    Keen, John D; Jørgensen, Karsten J

    2015-11-01

    This article reviews four important screening principles applicable to screening mammography in order to facilitate informed choice. The first principle is that screening may help, hurt, or have no effect. In order to reduce mortality and mastectomy rates, screening must reduce the rate of advanced disease, which likely has not happened. Through overdiagnosis, screening produces substantial harm by increasing both lumpectomy and mastectomy rates, which offsets the often-promised benefit of less invasive therapy. Next, all-cause mortality is the most reliable way to measure the efficacy of a screening intervention. Disease-specific mortality is biased due to difficulties in attribution of cause of death and to increased mortality due to overdiagnosis and the resulting overtreatment with radiotherapy and chemotherapy. To enhance participation, the benefit from screening is often presented in relative instead of absolute terms. Third, some screening statistics must be interpreted with caution. Increased survival time and the percentage of early-stage tumors at detection sound plausible, but are affected by lead-time and length biases. In addition, analyses that only include women who attend screening cannot reliably correct for selection bias. The final principle is that accounting for tumor biology is important for accurate estimates of lead time, and the potential benefit from screening. Since "early detection" is actually late in a tumor's lifetime, the time window when screen detection might extend a woman's life is narrow, as many tumors that can form metastases will already have done so. Instead of encouraging screening mammography, physicians should help women make an informed decision as with any medical intervention.

  2. Translated Versions of Voice Handicap Index (VHI)-30 across Languages: A Systematic Review

    PubMed Central

    SEIFPANAHI, Sadegh; JALAIE, Shohreh; NIKOO, Mohammad Reza; SOBHANI-RAD, Davood

    2015-01-01

    Background: In this systematic review, the aim is to investigate different VHI-30 versions between languages regarding their validity, reliability and their translation process. Methods: Articles were extracted systematically from some of the prime databases including Cochrane, googlescholar, MEDLINE (via PubMed gate), Sciencedirect, Web of science, and their reference lists by Voice Handicap Index keyword with only title limitation and time of publication (from 1997 to 2014). However the other limitations (e.g. excluding non-English, other versions of VHI ones, and so on) applied manually after studying the papers. In order to appraise the methodology of the papers, three authors did it by 12-item diagnostic test checklist in “Critical Appraisal Skills Programme” or (CASP) site. After applying all of the screenings, the papers that had the study eligibility criteria such as; translation, validity, and reliability processes, included in this review. Results: The remained non-repeated articles were 12 from different languages. All of them reported validity, reliability and translation method, which presented in details in this review. Conclusion: Mainly the preferred method for translation in the gathered papers was “Brislin’s classic back-translation model (1970), although the procedure was not performed completely but it was more prominent than other translation procedures. High test-retest reliability, internal consistency and moderate construct validity between different languages in regards to all 3 VHI-30 domains confirm the applicability of translated VHI-30 version across languages. PMID:26056664

  3. Reliability and Validity of Korean Version of Apraxia Screen of TULIA (K-AST).

    PubMed

    Kim, Soo Jin; Yang, You-Na; Lee, Jong Won; Lee, Jin-Youn; Jeong, Eunhwa; Kim, Bo-Ram; Lee, Jongmin

    2016-10-01

    To evaluate the reliability and validity of Korean version of AST (K-AST) as a bedside screening test of apraxia in patients with stroke for early and reliable detection. AST was translated into Korean, and the translated version received authorization from the author of AST. The performances of K-AST in 26 patients (21 males, 5 females; mean age 65.42±17.31 years) with stroke (23 ischemic, 3 hemorrhagic) were videotaped. To test the reliability and validity of K-AST, the recorded performances were assessed by two physiatrists and two occupational therapists twice at a 1-week interval. The patient performances at admission in Korean version of Mini-Mental State Examination (K-MMSE), self-care and transfer categories of Functional Independence Measure (FIM), and motor praxis area of Loewenstein Occupational Therapy Cognitive Assessment, the second edition (LOTCA-II) were also evaluated. Scores of motor praxis area of LOTCA-II was used to assess the validity of K-AST. Inter-rater reliabilities were 0.983 (p<0.001) at the first assessment and 0.982 (p<0.001) at the second assessment. For intra-rater (test-retest) reliabilities, the values of four raters were 0.978 (p<0.001), 0.957 (p<0.001), 0.987 (p<0.001), and 0.977 (p<0.001). K-AST showed significant correlation (r=0.758, p<0.001) with motor praxis area of LOTCA-II test. K-AST also showed positive correlations with the total FIM score (r=0.694, p<0.001), the selfcare category of FIM (r=0.705, p<0.001) and the transfer category of FIM (r=653, p<0.001). K-AST is a reliable and valid test for bedside screening of apraxia.

  4. Specific algorithm method of scoring the Clock Drawing Test applied in cognitively normal elderly

    PubMed Central

    Mendes-Santos, Liana Chaves; Mograbi, Daniel; Spenciere, Bárbara; Charchat-Fichman, Helenice

    2015-01-01

    The Clock Drawing Test (CDT) is an inexpensive, fast and easily administered measure of cognitive function, especially in the elderly. This instrument is a popular clinical tool widely used in screening for cognitive disorders and dementia. The CDT can be applied in different ways and scoring procedures also vary. Objective The aims of this study were to analyze the performance of elderly on the CDT and evaluate inter-rater reliability of the CDT scored by using a specific algorithm method adapted from Sunderland et al. (1989). Methods We analyzed the CDT of 100 cognitively normal elderly aged 60 years or older. The CDT ("free-drawn") and Mini-Mental State Examination (MMSE) were administered to all participants. Six independent examiners scored the CDT of 30 participants to evaluate inter-rater reliability. Results and Conclusion A score of 5 on the proposed algorithm ("Numbers in reverse order or concentrated"), equivalent to 5 points on the original Sunderland scale, was the most frequent (53.5%). The CDT specific algorithm method used had high inter-rater reliability (p<0.01), and mean score ranged from 5.06 to 5.96. The high frequency of an overall score of 5 points may suggest the need to create more nuanced evaluation criteria, which are sensitive to differences in levels of impairment in visuoconstructive and executive abilities during aging. PMID:29213954

  5. New Evidence for the Effectiveness of the Early Screening Inventory.

    ERIC Educational Resources Information Center

    Meisels, Samuel J.; And Others

    1993-01-01

    Examines the psychometric properties of the Early Screening Inventory (ESI), a developmental screening instrument designed to identify four- to six-year-olds at high risk for school failure. The ESI was found to be highly reliable and predictive, and it may be possible to increase its accuracy by combining it with the related Parent Questionnaire.…

  6. Pupil light reflex evoked by light-emitting diode and computer screen: Methodology and association with need for recovery in daily life.

    PubMed

    Wang, Yang; Zekveld, Adriana A; Wendt, Dorothea; Lunner, Thomas; Naylor, Graham; Kramer, Sophia E

    2018-01-01

    Pupil light reflex (PLR) has been widely used as a method for evaluating parasympathetic activity. The first aim of the present study is to develop a PLR measurement using a computer screen set-up and compare its results with the PLR generated by a more conventional setup using light-emitting diode (LED). The parasympathetic nervous system, which is known to control the 'rest and digest' response of the human body, is considered to be associated with daily life fatigue. However, only few studies have attempted to test the relationship between self-reported daily fatigue and physiological measurement of the parasympathetic nervous system. Therefore, the second aim of this study was to investigate the relationship between daily-life fatigue, assessed using the Need for Recovery scale, and parasympathetic activity, as indicated by the PLR parameters. A pilot study was conducted first to develop a PLR measurement set-up using a computer screen. PLRs evoked by light stimuli with different characteristics were recorded to confirm the influence of light intensity, flash duration, and color on the PLRs evoked by the system. In the subsequent experimental study, we recorded the PLR of 25 adult participants to light flashes generated by the screen set-up as well as by a conventional LED set-up. PLR parameters relating to parasympathetic and sympathetic activity were calculated from the pupil responses. We tested the split-half reliability across two consecutive blocks of trials, and the relationships between the parameters of PLRs evoked by the two set-ups. Participants rated their need for recovery prior to the PLR recordings. PLR parameters acquired in the screen and LED set-ups showed good reliability for amplitude related parameters. The PLRs evoked by both set-ups were consistent, but showed systematic differences in absolute values of all parameters. Additionally, higher need for recovery was associated with faster and larger constriction of the PLR. This study assessed the PLR generated by a computer screen and the PLR generated by a LED. The good reliability within set-ups and the consistency between the PLRs evoked by the set-ups indicate that both systems provides a valid way to evoke the PLR. A higher need for recovery was associated with faster and larger constricting PLRs, suggesting increased levels of parasympathetic nervous system activity in people experiencing higher levels of need for recovery on a daily basis.

  7. Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone.

    PubMed

    Harvey, Virginia L; Egerton, Victoria M; Chamberlain, Andrew T; Manning, Phillip L; Buckley, Michael

    2016-01-01

    Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six (14)C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated (14)C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 1(4)C analysis.

  8. Collagen Fingerprinting: A New Screening Technique for Radiocarbon Dating Ancient Bone

    PubMed Central

    Harvey, Virginia L.; Egerton, Victoria M.; Chamberlain, Andrew T.; Manning, Phillip L.; Buckley, Michael

    2016-01-01

    Collagen is the dominant organic component of bone and is intimately locked within the hydroxyapatite structure of this ubiquitous biomaterial that dominates archaeological and palaeontological assemblages. Radiocarbon analysis of extracted collagen is one of the most common approaches to dating bone from late Pleistocene or Holocene deposits, but dating is relatively expensive compared to other biochemical techniques. Numerous analytical methods have previously been investigated for the purpose of screening out samples that are unlikely to yield reliable dates including histological analysis, UV-stimulated fluorescence and, most commonly, the measurement of percentage nitrogen (%N) and ratio of carbon to nitrogen (C:N). Here we propose the use of collagen fingerprinting (also known as Zooarchaeology by Mass Spectrometry, or ZooMS, when applied to species identification) as an alternative screening method for radiocarbon dating, due to its ability to provide information on collagen presence and quality, alongside species identification. The method was tested on a series of sub-fossil bone specimens from cave systems on Cayman Brac (Cayman Islands), chosen due to the observable range in diagenetic alteration, and in particular, the extent of mineralisation. Six 14C dates, of 18 initial attempts, were obtained from remains of extinct hutia, Capromys sp. (Rodentia; Capromyidae), recovered from five distinct caves on Cayman Brac, and ranging from 393 ± 25 to 1588 ± 26 radiocarbon years before present (yr BP). All of the bone samples that yielded radiocarbon dates generated excellent collagen fingerprints, and conversely those that gave poor fingerprints also failed dating. Additionally, two successfully fingerprinted bone samples were screened out from a set of 81. Both subsequently generated 14C dates, demonstrating successful utilisation of ZooMS as an alternative screening mechanism to identify bone samples that are suitable for 14C analysis. PMID:26938469

  9. Psychometric Properties of the Breast Cancer Screening Beliefs Questionnaire Among Women of Indian Ethnicity Living in Australia.

    PubMed

    Kwok, Cannas; Pillay, Rona; Lee, Chun Fan

    2016-01-01

    Indian women have been consistently reported as having low participation in breast cancer screening practices. A valid and reliable instrument to explore their breast cancer beliefs is essential for development of interventions to promote breast cancer screening practices. The aim of this study was to report the psychometric properties of the Breast Cancer Screening Beliefs Questionnaire (BCSBQ) in an Indian community in Australia. A convenience sample of 242 Indian Australian women was recruited from Indian community organizations and personal networking. Explanatory factor analysis was conducted to study the factor structure. Clinical validity was examined by Cuzick's nonparametric test, and Cronbach's α was used to assess internal consistency reliability. Exploratory factor analysis showed a similar fit to the hypothesized 3-factor structure. The frequency of breast cancer screening practices was significantly associated with attitudes toward general health check-up. Knowledge and perceptions about the breast cancer scale were not significantly associated with clinical breast examinations and mammography. Perceived barriers to mammography were much less evident among women who engaged in breast awareness and clinical breast examination. Results indicated that the BCSBQ had satisfactory validity and internal consistency. Cronbach's α of the 3 subscales ranged from .81 to .91. The BCSBQ is a culturally appropriate, valid, and reliable instrument for assessing the beliefs, knowledge, and attitudes about breast cancer and breast cancer screening practices among women of Indian ethnic extraction living in Australia. The BCSBQ can be used to provide nurses with information relevant for the development of culturally sensitive breast health education programs.

  10. Biochemical verification of the self-reported smoking status of screened male smokers of the Dutch-Belgian randomized controlled lung cancer screening trial.

    PubMed

    van der Aalst, Carlijn M; de Koning, Harry J

    2016-04-01

    Smoking is the main cause of lung cancer, so data linked to smoking behaviour are important in lung cancer screening trials. However, self-reporting data concerning smoking behaviour are mainly used. The aim of this study was to biochemically determine the validity and reliability of self-reported smoking status among smokers at high risk for developing lung cancer participating in the Dutch-Belgian lung cancer screening (NELSON) trial. For this sub study, a random sample of 475 men was selected who were scheduled for the fourth screening round in the NELSON trial. They were asked to complete a short questionnaire to verify the smoking behaviour for the previous seven days and a blood sample was collected to measure the cotinine level. The validity (sensitivity (Se), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV)) and reliability (Kappa) of the self-reported smoking status compared to the cotinine level (as golden standard) were determined. Both a completed questionnaire as well as a cotinine level were available for 199 (41.9%) participants. Based on these data, Se and Sp were respectively 98% (95%-Confidence Interval (CI): 91-99) and 98% (95%-CI: 93-100). PPV and NPV were 98% and 96% and Kappa was 0.96. In conclusion, the validity of the self-reported smoking status turned out to be reliable amongst men at high risk for developing lung cancer who participate in the NELSON lung cancer screening trial. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Design of an everting balloon to deploy a microendoscope to the fallopian tubes

    NASA Astrophysics Data System (ADS)

    Keenan, Molly; Howard, Caitlin; Tate, Tyler; McGuiness, Ian; Sauer-Budge, Alexis; Black, John; Utzinger, Urs; Barton, Jennifer K.

    2016-02-01

    The 5-year survival rate for ovarian cancer is only 45% largely due to lack of effective screening methods. Current methods include palpation, transvaginal ultrasound, and the CA-125 blood test. Finding disease reliably and at an early stage increase survival to 92%. We have designed and built a 0.7 mm endoscope for the early detection of ovarian cancer. Inserted transvaginally through the working channel of a hysteroscope, the falloposcope creates a minimally invasive procedure for the screening of high risk women. To improve the ease-of-use and safety of falloposcope deployment, we are working to create an everting balloon. Currently, the falloposcope would require a skilled user to operate due to the challenging anatomy of the fallopian tubes - a small opening from the uterus (< 1 mm), tortuous path, and delicate lumenal features. A balloon delivery system would gently open the fallopian tube and guide the falloposcope down the center of lumen. We show balloon design and discuss integration with the falloposcope prototype. We test possible mechanical damage to the tissue due to scraping, puncture, or overstretching. Successful introduction of the everting balloon to simplify falloposcope delivery could expand screening beyond specialized centers to smaller clinical locations.

  12. Screening and analysis of the multiple absorbed bioactive components and metabolites in rat plasma after oral administration of Jitai tablets by high-performance liquid chromatography/diode-array detection coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Wang, Shu-Ping; Liu, Lei; Wang, Ling-Ling; Jiang, Peng; Zhang, Ji-Quan; Zhang, Wei-Dong; Liu, Run-Hui

    2010-06-15

    Based on the serum pharmacochemistry technique and high-performance liquid chromatography/diode-array detection (HPLC/DAD) coupled with electrospray tandem mass spectrometry (HPLC/ESI-MS/MS), a method for screening and analysis of the multiple absorbed bioactive components and metabolites of Jitai tablets (JTT) in orally dosed rat plasma was developed. Plasma was treated by methanol precipitation prior to liquid chromatography, and the separation was carried out on a Symmetry C(18) column, with a linear gradient (0.1% formic acid/water/acetonitrile). Mass spectra were acquired in negative and positive ion modes, respectively. As a result, 26 bioactive components originated from JTT and 5 metabolites were tentatively identified in orally dosed rat plasma by comparing their retention times and MS spectra with those of authentic standards and literature data. It is concluded that an effective and reliable analytical method was set up for screening the bioactive components of Chinese herbal medicine, which provided a meaningful basis for further pharmacology and active mechanism research of JTT. Copyright (c) 2010 John Wiley & Sons, Ltd.

  13. Rapid screening for nuclear genes mutations in isolated respiratory chain complex I defects.

    PubMed

    Pagniez-Mammeri, Hélène; Lombes, Anne; Brivet, Michèle; Ogier-de Baulny, Hélène; Landrieu, Pierre; Legrand, Alain; Slama, Abdelhamid

    2009-04-01

    Complex I or reduced nicotinamide adenine dinucleotide (NADH): ubiquinone oxydoreductase deficiency is the most common cause of respiratory chain defects. Molecular bases of complex I deficiencies are rarely identified because of the dual genetic origin of this multi-enzymatic complex (nuclear DNA and mitochondrial DNA) and the lack of phenotype-genotype correlation. We used a rapid method to screen patients with isolated complex I deficiencies for nuclear genes mutations by Surveyor nuclease digestion of cDNAs. Eight complex I nuclear genes, among the most frequently mutated (NDUFS1, NDUFS2, NDUFS3, NDUFS4, NDUFS7, NDUFS8, NDUFV1 and NDUFV2), were studied in 22 cDNA fragments spanning their coding sequences in 8 patients with a biochemically proved complex I deficiency. Single nucleotide polymorphisms and missense mutations were detected in 18.7% of the cDNA fragments by Surveyor nuclease treatment. Molecular defects were detected in 3 patients. Surveyor nuclease screening is a reliable method for genotyping nuclear complex I deficiencies, easy to interpret, and limits the number of sequence reactions. Its use will enhance the possibility of prenatal diagnosis and help us for a better understanding of complex I molecular defects.

  14. Adolescent Risk Screening Instruments for Primary Care: An Integrative Review Utilizing the Donabedian Framework.

    PubMed

    Hiott, Deanna B; Phillips, Shannon; Amella, Elaine

    2017-07-31

    Adolescent risk-taking behavior choices can affect future health outcomes. The purpose of this integrative literature review is to evaluate adolescent risk screening instruments available to primary care providers in the United States using the Donabedian Framework of structure, process, and outcome. To examine the literature concerning multidimensional adolescent risk screening instruments available in the United States for use in the primary care setting, library searches, ancestry searches, and Internet searches were conducted. Library searches included a systematic search of the Cumulative Index to Nursing and Allied Health Literature (CINAHL), Academic Search Premier, Health Source Nursing Academic Ed, Medline, PsycINFO, the Psychology and Behavioral Sciences Collection, and PubMed databases with CINAHL headings using the following Boolean search terms: "primary care" and screening and pediatric. Criteria for inclusion consisted of studies conducted in the United States that involved broad multidimensional adolescent risk screening instruments for use in the pediatric primary care setting. Instruments that focused solely on one unhealthy behavior were excluded, as were developmental screens and screens not validated or designed for all ages of adolescents. In all 25 manuscripts reviewed, 16 screens met the inclusion criteria and were included in the study. These 16 screens were examined for factors associated with the Donabedian structure-process-outcome model. This review revealed that many screens contain structural issues related to cost and length that inhibit provider implementation in the primary care setting. Process limitations regarding the report method and administration format were also identified. The Pediatric Symptom Checklist was identified as a free, short tool that is valid and reliable.

  15. Emotional and Behavioral Screener: Test-Retest Reliability, Inter-Rater Reliability, and Convergent Validity

    ERIC Educational Resources Information Center

    Nordness, Philip D.; Epstein, Michael H.; Cullinan, Douglas; Pierce, Corey D.

    2014-01-01

    The Emotional and Behavioral Screener (EBS) is a universal screening instrument designed to identify students whose excessive problem behaviors put them at risk of the education disability category of emotional disturbance (ED). This article reports findings from three studies that address the reliability and validity of the EBS. Studies 1 and 2…

  16. Assuring reliability program effectiveness.

    NASA Technical Reports Server (NTRS)

    Ball, L. W.

    1973-01-01

    An attempt is made to provide simple identification and description of techniques that have proved to be most useful either in developing a new product or in improving reliability of an established product. The first reliability task is obtaining and organizing parts failure rate data. Other tasks are parts screening, tabulation of general failure rates, preventive maintenance, prediction of new product reliability, and statistical demonstration of achieved reliability. Five principal tasks for improving reliability involve the physics of failure research, derating of internal stresses, control of external stresses, functional redundancy, and failure effects control. A final task is the training and motivation of reliability specialist engineers.

  17. Developing a Behavioral Health Screening Program for BSL-4 Laboratory Workers at the National Institutes of Health

    PubMed Central

    Wilson, Deborah E.

    2011-01-01

    The events and aftermath of September 11, 2001, accelerated a search for personnel reliability test measures to identify individuals who could pose a threat to our nation's security and safety. The creation and administration of a behavioral health screen for BSL-4 laboratory workers at the National Institutes of Health represents a pioneering effort to proactively build a BSL-4 safety culture promoting worker cohesiveness, trust, respect, and reliability with a balance of worker privacy and public safety. PMID:21361798

  18. Pre-screening method for somatic cell contamination in human sperm epigenetic studies.

    PubMed

    Jenkins, Timothy G; Liu, Lihua; Aston, Kenneth I; Carrell, Douglas T

    2018-04-01

    Sperm epigenetic profiles are frequently studied and are of great interest in many fields. One major technical concern when assessing these marks is the potential for somatic cell contamination. Because somatic cells have dramatically different epigenetic signatures, even small levels of contamination can result in significant problems in analysis and interpretation of data. In this study we evaluate an assay, which we designed to offer a reliable 'pre-screen' for somatic cell contamination that directly assesses the DNA being used in the study to determine tissue purity. In brief, we designed an inexpensive and simple assay that utilizes the strong differential methylation between sperm and somatic cells at four genomic loci to assess the general purity of samples prior to performing expensive and time intensive assays. The assay is able to reliably detect contamination qualitatively by running the sample on an agarose gel, or quantitatively with the use of a bioanalyzer. With this technique we have found that we can detect potentially contaminating signals in samples of many different types, including those from patients with poor sperm phenotypes (oligozoospermia, asthenozoospermia, and teratozoospermia). We also have found that the use of multiple sites to determine potential contamination is key, as some conditions (asthenozoospermia specifically) appear at one site to reflect a somatic-like profile, while at all other sites it appears to have very typical sperm DNA methylation signatures. Taken together, the use of the assay described herein was effective at identifying contamination and could be implemented in many labs to quickly and inexpensively pre-screen samples prior to performing far more expensive and labor intensive procedures. Additionally, the principles applied to the development of this assay could be easily adapted for the development of other assays to pre-screen different tissue/cell types or model organisms.

  19. Factor Structure and Stability of Smoking-Related Health Beliefs in the National Lung Screening Trial

    PubMed Central

    Koblitz, Amber R.; Persoskie, Alexander; Ferrer, Rebecca A.; Klein, William M. P.; Dwyer, Laura A.; Park, Elyse R.

    2016-01-01

    Introduction: Absolute and comparative risk perceptions, worry, perceived severity, perceived benefits, and self-efficacy are important theoretical determinants of tobacco use, but no measures have been validated to ensure the discriminant validity as well as test-retest reliability of these measures in the tobacco context. The purpose of the current study is to examine the reliability and factor structure of a measure assessing smoking-related health cognitions and emotions in a national sample of current and former heavy smokers in the National Lung Screening Trial. Methods: A sub-study of the National Lung Screening Trial assessed current and former smokers’ (age 55–74; N = 4379) self-reported health cognitions and emotions at trial enrollment and at 12-month follow-up. Items were derived from the Health Belief Model and Self-Regulation Model. Results: An exploratory factor analysis of baseline responses revealed a five-factor structure for former smokers (risk perceptions, worry, perceived severity, perceived benefits, and self-efficacy) and a six-factor structure for current smokers, such that absolute risk and comparative risk perceptions emerged as separate factors. A confirmatory factor analysis of 12-month follow-up responses revealed a good fit for the five latent constructs for former smokers and six latent constructs for current smokers. Longitudinal stability of these constructs was also demonstrated. Conclusions: This is the first study to examine tobacco-related health cognition and emotional constructs over time in current and former heavy smokers undergoing lung screening. This study found that the theoretical constructs were stable across time and that the factor structure differed based on smoking status (current vs. former). PMID:25964503

  20. Early detection of Alzheimer disease: methods, markers, and misgivings.

    PubMed

    Green, R C; Clarke, V C; Thompson, N J; Woodard, J L; Letz, R

    1997-01-01

    There is at present no reliable predictive test for most forms of Alzheimer disease (AD). Although some information about future risk for disease is available in theory through ApoE genotyping, it is of limited accuracy and utility. Once neuroprotective treatments are available for AD, reliable early detection will become a key component of the treatment strategy. We recently conducted a pilot survey eliciting attitudes and beliefs toward an unspecified and hypothetical predictive test for AD. The survey was completed by a convenience sample of 176 individuals, aged 22-77, which was 75% female, 30% African-American, and of which 33% had a family member with AD. The survey revealed that 69% of this sample would elect to obtain predictive testing for AD if the test were 100% accurate. Individuals were more likely to desire predictive testing if they had an a priori belief that they would develop AD (p = 0.0001), had a lower educational level (p = 0.003), were worried that they would develop AD (p = 0.02), had a self-defined history of depression (p = 0.04), and had a family member with AD (p = 0.04). However, the desire for predictive testing was not significantly associated with age, gender, ethnicity, or income. The desire to obtain predictive testing for AD decreased as the assumed accuracy of the hypothetical test decreased. A better short-term strategy for early detection of AD may be computer-based neuropsychological screening of at-risk (older aged) individuals to identify very early cognitive impairment. Individuals identified in this manner could be referred for diagnostic evaluation and early cases of AD could be identified and treated. A new self-administered, touch-screen, computer-based, neuropsychological screening instrument called Neurobehavioral Evaluation System-3 is described, which may facilitate this type of screening.

  1. THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS).

    PubMed

    McCunn, Robert; Aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim

    2017-02-01

    The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the 'pure' intra-rater (intra-occasion) reliability for those movements. Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate the relationship between test score and subsequent injury. The present results indicate acceptable reliability for this purpose; however, room for further development of the intra-rater reliability exists for some of the individual sub-tests. 2b.

  2. The identification and appraisal of assessment tools used to evaluate metatarsus adductus: a systematic review of their measurement properties.

    PubMed

    Marshall, Nicole; Ward, Emily; Williams, Cylie M

    2018-01-01

    Metatarsus adductus is the most common congenital foot deformity in newborns. It involves adduction of the metatarsals at the Lisfranc joint. A systematic literature review was conducted to investigate the following question: What tools are used to identify and quantify metatarsus adductus and how reliable, valid and responsive are they? The following electronic databases were searched for studies describing tools for the identification and quantification of metatarsus adductus in adults and children published from inception to June 2016: Ovid MEDLINE, Embase, CINAHL, Scopus, Web of Science and AMED. Two researchers initially searched all articles by screening titles and abstracts. If there was any doubt as to an article's eligibility, the full text paper was retrieved. Reference lists and citations of all retained studies were examined in an attempt to locate further studies. Articles were excluded if they were not in English or described other congenital foot conditions that did not include metatarsus adductus. Studies included in the review reporting measurement properties of measurement tools were critically appraised using the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) critical appraisal tool. There were 282 articles screened by title and abstract and 28 articles screened from full text. Fifteen articles were included and nine had data that were extractable for appraisal using the COSMIN critical appraisal tool. Techniques to measure metatarsus adductus included the heel bisector method, photocopies, ultrasound, footprints, dynamic foot pressure and radiographs. There was a paucity of quality data reporting the reliability, validity or responsiveness for measuring metatarsus adductus. Several radiographic angles showed good reliability (intraclass correlation (ICC) - 0.84, 0.97) in adults during pre-operative planning. There have been multiple assessment techniques proposed for quantification of metatarsus adductus, but there is paucity of reliability, validity or responsiveness to measurement data about these techniques, especially in relation to the paediatric population. Further consideration of measurement testing is required to determine if the most common non-radiographic measures of metatarsus adductus are acceptable for clinical use.

  3. A Spanish Validation of the Canadian Adolescent Gambling Inventory (CAGI).

    PubMed

    Jiménez-Murcia, Susana; Granero, Roser; Stinchfield, Randy; Tremblay, Joël; Del Pino-Gutiérrez, Amparo; Moragas, Laura; Savvidou, Lamprini G; Fernández-Aranda, Fernando; Aymamí, Neus; Gómez-Peña, Mónica; Tárrega, Salomé; Gunnard, Katarina; Martín-Romera, Virginia; Steward, Trevor; Mestre-Bach, Gemma; Menchón, José M

    2017-01-01

    Aims: Large-scale epidemiological studies show a significant prevalence of gambling disorder (GD) during adolescence and emerging adulthood, and highlight the need to identify gambling-related behaviors at early ages. However, there are only a handful of screening instruments for this population and many studies measuring youth gambling problems use adult instruments that may not be developmentally appropriate. The aim of this study was to validate a Spanish version of the Canadian Adolescent Gambling Inventory (CAGI) among late adolescent and young adults and to explore its psychometric properties. Methods: The sample (16-29 years old) included a clinical group ( n = 55) with GD patients and a control group ( n = 340). Results: Exploratory factor analysis yielded one factor as the best model. This 24-item scale demonstrated satisfactory reliability (internal consistency, Cronbach's alpha, α = 0.91), satisfactory convergent validity as measured by correlation with South Oaks Gambling Screen ( r = 0.74), and excellent classification accuracy (AUC = 0.99; sensitivity = 0.98; and specificity = 0.99). Conclusion: Our results provide empirical support for our validation of the Spanish version of the CAGI. We uphold that the Spanish CAGI can be used as a brief, reliable, and valid instrument to assess gambling problems in Spanish youth.

  4. Cryogenic Quenching Process for Electronic Part Screening

    NASA Technical Reports Server (NTRS)

    Sheldon, Douglas J.; Cressler, John

    2011-01-01

    The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.

  5. Subjective Global Nutritional Assessment: A Reliable Screening Tool for Nutritional Assessment in Cerebral Palsy Children.

    PubMed

    Minocha, Priyanka; Sitaraman, Sadasivan; Choudhary, Anita; Yadav, Rajiv

    2018-01-01

    To determine the prevalence of undernutrition in children with cerebral palsy and to compare subjective and objective methods of nutritional assessment. This was a hospital based analytical observational study in which 180 children of cerebral palsy, aged 1-12 y, attending tertiary level hospital, Jaipur from March, 2012 through March, 2013 were included. Subjective assessment was done by questionnaire (Subjective Global Nutritional Assessment; SGNA) in which questions related to nutrition history and physical examination, signs of fat, muscle wasting and edema was done while objective assessment was done by weight, height and triceps skinfold thickness (TSFT) measurements. In this study prevalence of undernutrition by subjective method (SGNA) was 76.67% while by objective measurement (weight, height, TSFT) was 48.89%, 77.78% 35.18% respectively. There was fair to moderate agreement between the SGNA and objective assessments including weight and height (k = 0.341, p = 0.000; k = 0.337, p = 0.000 respectively) while for TSFT agreement between both methods was poor (k = 0.092, p = 0.190). In the index study, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of SGNA was for weight was 95%, 37%, 56%, 90%; for height 84%, 50%, 85%, 47%; for TSFT 81%, 30%, 38%, 75% respectively. The prevalence of undernutrition is high in cerebral palsy children. SGNA can be a reliable tool for assessing nutritional status in children with cerebral palsy and is a simple, comprehensive, noninvasive, and cost-effective tool for screening undernutrition in children of cerebral palsy.

  6. Development of selective blockers for Ca2+-activated Cl- channel using Xenopus laevis oocytes with an improved drug screening strategy

    PubMed Central

    Oh, Soo-Jin; Park, Jung Hwan; Han, Sungyu; Lee, Jae Kyun; Roh, Eun Joo; Lee, C Justin

    2008-01-01

    Background Ca2+-activated Cl- channels (CaCCs) participate in many important physiological processes. However, the lack of effective and selective blockers has hindered the study of these channels, mostly due to the lack of good assay system. Here, we have developed a reliable drug screening method for better blockers of CaCCs, using the endogeneous CaCCs in Xenopus laevis oocytes and two-electrode voltage-clamp (TEVC) technique. Results Oocytes were prepared with a treatment of Ca2+ ionophore, which was followed by a treatment of thapsigargin which depletes Ca2+ stores to eliminate any contribution of Ca2+ release. TEVC was performed with micropipette containing chelerythrine to prevent PKC dependent run-up or run-down. Under these conditions, Ca2+-activated Cl- currents induced by bath application of Ca2+ to oocytes showed stable peak amplitude when repetitively activated, allowing us to test several concentrations of a test compound from one oocyte. Inhibitory activities of commercially available blockers and synthesized anthranilic acid derivatives were tested using this method. As a result, newly synthesized N-(4-trifluoromethylphenyl)anthranilic acid with trifluoromethyl group (-CF3) at para position on the benzene ring showed the lowest IC50. Conclusion Our results provide an optimal drug screening strategy suitable for high throughput screening, and propose N-(4-trifluoromethylphenyl)anthranilic acid as an improved CaCC blocker. PMID:18959787

  7. Reliability and validity of depression assessment among persons with HIV in sub-Saharan Africa: systematic review and meta-analysis

    PubMed Central

    Tsai, Alexander C.

    2014-01-01

    OBJECTIVES To systematically review the reliability and validity of instruments used to screen for major depressive disorder or assess depression symptom severity among persons with HIV in sub-Saharan Africa. DESIGN Systematic review and meta-analysis. METHODS A systematic evidence search protocol was applied to seven bibliographic databases. Studies examining the reliability and/or validity of depression assessment tools were selected for inclusion if they were based on data collected from HIV-positive adults in any African member state of the United Nations. Random-effects meta-analysis was employed to calculate pooled estimates of depression prevalence. In a subgroup of studies of criterion-related validity, the bivariate random-effects model was used to calculate pooled estimates of sensitivity and specificity. RESULTS Of 1,117 records initially identified, I included 13 studies of 5,373 persons with HIV in 7 sub-Saharan African countries. Reported estimates of Cronbach’s alpha ranged from 0.63–0.95, and analyses of internal structure generally confirmed the existence of a depression-like construct accounting for a substantial portion of variance. The pooled prevalence of probable depression was 29.5% (95% CI, 20.5–39.4), while the pooled prevalence of major depressive disorder was 13.9% (95% CI, 9.7–18.6). The Center for Epidemiologic Studies-Depression scale was the most frequently studied instrument, with a pooled sensitivity of 0.82 (95% CI, 0.73–0.87) for detecting major depressive disorder. CONCLUSIONS Depression screening instruments yielded relatively high false positive rates. Overall, few studies described the reliability and/or validity of depression instruments in sub-Saharan Africa. PMID:24853307

  8. Application of Infrared and Raman Spectroscopy for the Identification of Disease Resistant Trees.

    PubMed

    Conrad, Anna O; Bonello, Pierluigi

    2015-01-01

    New approaches for identifying disease resistant trees are needed as the incidence of diseases caused by non-native and invasive pathogens increases. These approaches must be rapid, reliable, cost-effective, and should have the potential to be adapted for high-throughput screening or phenotyping. Within the context of trees and tree diseases, we summarize vibrational spectroscopic and chemometric methods that have been used to distinguish between groups of trees which vary in disease susceptibility or other important characteristics based on chemical fingerprint data. We also provide specific examples from the literature of where these approaches have been used successfully. Finally, we discuss future application of these approaches for wide-scale screening and phenotyping efforts aimed at identifying disease resistant trees and managing forest diseases.

  9. Detection of Large Pathogenic Expansions in FRDA1, SCA10, and SCA12 Genes Using a Simple Fluorescent Repeat-Primed PCR Assay

    PubMed Central

    Cagnoli, Claudia; Michielotto, Chiara; Matsuura, Tohru; Ashizawa, Tetsuo; Margolis, Russell L.; Holmes, Susan E.; Gellera, Cinzia; Migone, Nicola; Brusco, Alfredo

    2004-01-01

    At least 18 human genetic diseases are caused by expansion of short tandem repeats. Here we describe a successful application of a fluorescent PCR method for the detection of expanded repeats in FRDA1, SCA10, and SCA12 genes. Although this test cannot give a precise estimate of the size of the expansion, it is robust, reliable, and inexpensive, and can be used to screen large series of patients. It proved useful for confirming the presence of large expansions in the Friedreich ataxia gene following an ambiguous result of long-range PCR, as well as rapid pre-screening for large repeat expansions associated with Friedreich ataxia and SCA10 and the shorter repeat expansions associated with SCA12. PMID:15096564

  10. The reliability and validity of the Greenspan Social Emotional Growth Chart (GSEGC) in Israeli children with developmental delay and autism-A pilot study.

    PubMed

    Tede, Zoma; Ophir Cohen, Michal; Riskin, Arieh; Tirosh, Emanuel

    2016-08-01

    Healthy social-emotional development in early childhood is important as an indicator of general well-being and for positive outcome in later childhood. Therefore, screening for potential social emotional problems is valuable. Accurate, usable, and affordable screening tools have been especially difficult to develop. The cross cultural validity of a screening instrument should be assessed. The aim of the current study was to investigate the reliability and validity of the Greenspan social-emotional growth chart (GSEGC) in Israeli children of three diagnostic groups: (1) Autistic spectrum disorder (ASD) (2) Developmental language disorder (DLD) and (3) Developmental motor delay (DMD). An internal reliability of alpha of 0.95 for the GSEGC standardized for age score and of 0.78 for the sensory processing sub scores was found. A confirmatory factor analysis (CFA) using a 5-factor model confirmed an acceptable fit. Positive (62.86%) and negative (94.73%) predictive values also support the clinical usefulness of the GSEGC in identifying children at low risk for ASD. The GSEGC appears to be a promising tool for the screening of social emotional problems in early childhood. Further studies in different cultures are warranted. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Nutrition Risk in Home-Bound Older Adults: Using Dietician-Trained and Supervised Nutrition Volunteers for Screening and Intervention

    ERIC Educational Resources Information Center

    Laforest, Sophie; Goldin, Benita; Nour, Kareen; Roy, Marie-Andree; Payette, Helene

    2007-01-01

    Nutrition screening and early intervention in home-bound older adults are key to preventing unfavourable health outcomes and functional decline. This pilot study's objectives were (a) to test the reliability of the Elderly Nutrition Screening Tool (ENS [C]) when administered by dietician-trained and supervised nutrition volunteers, and (b) to…

  12. The Relationship of Eye Anomalies and Reading Ability, and an Analysis of Vision-Screening Programs. (Volumes I and II).

    ERIC Educational Resources Information Center

    Francis, Leslie John

    The purpose of this study was to provide an in-depth analysis of vision-screening programs in relation to their efficacy, appropriateness, and feasibility for public school use. Twenty-two vision-screening programs were analyzed for reliability, validity, efficiency of identification and referral cost, and required testing time. Findings are that…

  13. A Primer for DoD Reliability, Maintainability and Safety Standards

    DTIC Science & Technology

    1988-03-02

    the project engineer and the concurrence of their respective managers. The primary consideration in such cases is the thoroughness of the ...basic approaches to the application of environmental stress screening. In one approach, the government explicitly specifies the screens and screening...TO USE DOD-HDBK-344 (USAF) There are two basic approaches to the application of environmental stress

  14. The Clinical Validation of the Athlete Sleep Screening Questionnaire: an Instrument to Identify Athletes that Need Further Sleep Assessment.

    PubMed

    Bender, Amy M; Lawson, Doug; Werthner, Penny; Samuels, Charles H

    2018-06-04

    Previous research has established that general sleep screening questionnaires are not valid and reliable in an athlete population. The Athlete Sleep Screening Questionnaire (ASSQ) was developed to address this need. While the initial validation of the ASSQ has been established, the clinical validity of the ASSQ has yet to be determined. The main objective of the current study was to evaluate the clinical validity of the ASSQ. Canadian National Team athletes (N = 199; mean age 24.0 ± 4.2 years, 62% females; from 23 sports) completed the ASSQ. A subset of athletes (N = 46) were randomized to the clinical validation sub-study which required subjects to complete an ASSQ at times 2 and 3 and to have a clinical sleep interview by a sleep medicine physician (SMP) who rated each subjects' category of clinical sleep problem and provided recommendations to improve sleep. To assess clinical validity, the SMP category of clinical sleep problem was compared to the ASSQ. The internal consistency (Cronbach's alpha = 0.74) and test-retest reliability (r = 0.86) of the ASSQ were acceptable. The ASSQ demonstrated good agreement with the SMP (Cohen's kappa = 0.84) which yielded a diagnostic sensitivity of 81%, specificity of 93%, positive predictive value of 87%, and negative predictive value of 90%. There were 25.1% of athletes identified to have clinically relevant sleep disturbances that required further clinical sleep assessment. Sleep improved from time 1 at baseline to after the recommendations at time 3. Sleep screening athletes with the ASSQ provides a method of accurately determining which athletes would benefit from preventative measures and which athletes suffer from clinically significant sleep problems. The process of sleep screening athletes and providing recommendations improves sleep and offers a clinical intervention output that is simple and efficient for teams and athletes to implement.

  15. Confocal nanoscanning, bead picking (CONA): PickoScreen microscopes for automated and quantitative screening of one-bead one-compound libraries.

    PubMed

    Hintersteiner, Martin; Buehler, Christof; Uhl, Volker; Schmied, Mario; Müller, Jürgen; Kottig, Karsten; Auer, Manfred

    2009-01-01

    Solid phase combinatorial chemistry provides fast and cost-effective access to large bead based libraries with compound numbers easily exceeding tens of thousands of compounds. Incubating one-bead one-compound library beads with fluorescently labeled target proteins and identifying and isolating the beads which contain a bound target protein, potentially represents one of the most powerful generic primary high throughput screening formats. On-bead screening (OBS) based on this detection principle can be carried out with limited automation. Often hit bead detection, i.e. recognizing beads with a fluorescently labeled protein bound to the compound on the bead, relies on eye-inspection under a wide-field microscope. Using low resolution detection techniques, the identification of hit beads and their ranking is limited by a low fluorescence signal intensity and varying levels of the library beads' autofluorescence. To exploit the full potential of an OBS process, reliable methods for both automated quantitative detection of hit beads and their subsequent isolation are needed. In a joint collaborative effort with Evotec Technologies (now Perkin-Elmer Cellular Technologies Germany GmbH), we have built two confocal bead scanner and picker platforms PS02 and a high-speed variant PS04 dedicated to automated high resolution OBS. The PS0X instruments combine fully automated confocal large area scanning of a bead monolayer at the bottom of standard MTP plates with semiautomated isolation of individual hit beads via hydraulic-driven picker capillaries. The quantification of fluorescence intensities with high spatial resolution in the equatorial plane of each bead allows for a reliable discrimination between entirely bright autofluorescent beads and real hit beads which exhibit an increased fluorescence signal at the outer few micrometers of the bead. The achieved screening speed of up to 200,000 bead assayed in less than 7 h and the picking time of approximately 1 bead/min allow exploitation of one-bead one-compound libraries with high sensitivity, accuracy, and speed.

  16. Validation of a condition-specific measure for women having an abnormal screening mammography.

    PubMed

    Brodersen, John; Thorsen, Hanne; Kreiner, Svend

    2007-01-01

    The aim of this study is to assess the validity of a new condition-specific instrument measuring psychosocial consequences of abnormal screening mammography (PCQ-DK33). The draft version of the PCQ-DK33 was completed on two occasions by 184 women who had received an abnormal screening mammography and on one occasion by 240 women who had received a normal screening result. Item Response Theories and Classical Test Theories were used to analyze data. Construct validity, concurrent validity, known group validity, objectivity and reliability were established by item analysis examining the fit between item responses and Rasch models. Six dimensions covering anxiety, behavioral impact, sense of dejection, impact on sleep, breast examination, and sexuality were identified. One item belonging to the dejection dimension had uniform differential item functioning. Two items not fitting the Rasch models were retained because of high face validity. A sick leave item added useful information when measuring side effects and socioeconomic consequences of breast cancer screening. Five "poor items" were identified and should be deleted from the final instrument. Preliminary evidence for a valid and reliable condition-specific measure for women having an abnormal screening mammography was established. The measure includes 27 "good" items measuring different attributes of the same overall latent structure-the psychosocial consequences of abnormal screening mammography.

  17. Validation of the Malay version of Berlin questionaire to identify Malaysian patients for obstructive sleep apnea.

    PubMed

    Yunus, A; Seet, W; Mohamad Adam, B; Haniff, J

    2013-01-01

    To validate the Malay version of Berlin Questionnaire (BQ) as a tool to screen for patients at risk of obstructive sleep apnea (OSA) in primary care. Most patients with OSA are unrecognised and untreated. Thus, the BQ has been used as a tool to screen for patients at risk for OSA. However, this tool has not been validated in Malay version. A parallel back-to-back translation method was applied to produce the Malay version (Berlin-M). The Malay version was administered to 150 patients in a tertiary respiratory medical centre.  Concurrent validity of the Berlin-M was determined using the Apnea Hypopnea Index (AHI) as the gold standard measure.  The test-retest reliability and internal consistency of the Berlin-M were determined. Most patients were males (64.0%) and majority of them were Malays (63.3%). Based on the sleep study test, 121 (84.0%) were classified as high risk while 23 (16.0%) as low risk using the Apnea Hypopnea Index (AHI) ≥5 as the cutoff point. The test-retest reliability Kappa value showed a good range between 0.864 - 1.000. The Cronbach's alpha of BQ was 0.750 in category 1 and 0.888 in category 2. The sensitivity and specificity were 92% and 17% respectively. The BQ showed high sensitivity (92%) but low specificity (17%). Therefore, though the Berlin-M is useful as a screening tool, it is not a confirmatory diagnostic tool.

  18. Factors Influencing the Reliability of the Glasgow Coma Scale: A Systematic Review.

    PubMed

    Reith, Florence Cm; Synnot, Anneliese; van den Brande, Ruben; Gruen, Russell L; Maas, Andrew Ir

    2017-06-01

    The Glasgow Coma Scale (GCS) characterizes patients with diminished consciousness. In a recent systematic review, we found overall adequate reliability across different clinical settings, but reliability estimates varied considerably between studies, and methodological quality of studies was overall poor. Identifying and understanding factors that can affect its reliability is important, in order to promote high standards for clinical use of the GCS. The aim of this systematic review was to identify factors that influence reliability and to provide an evidence base for promoting consistent and reliable application of the GCS. A comprehensive literature search was undertaken in MEDLINE, EMBASE, and CINAHL from 1974 to July 2016. Studies assessing the reliability of the GCS in adults or describing any factor that influences reliability were included. Two reviewers independently screened citations, selected full texts, and undertook data extraction and critical appraisal. Methodological quality of studies was evaluated with the consensus-based standards for the selection of health measurement instruments checklist. Data were synthesized narratively and presented in tables. Forty-one studies were included for analysis. Factors identified that may influence reliability are education and training, the level of consciousness, and type of stimuli used. Conflicting results were found for experience of the observer, the pathology causing the reduced consciousness, and intubation/sedation. No clear influence was found for the professional background of observers. Reliability of the GCS is influenced by multiple factors and as such is context dependent. This review points to the potential for improvement from training and education and standardization of assessment methods, for which recommendations are presented. Copyright © 2017 by the Congress of Neurological Surgeons.

  19. Evalution of DNA extraction methods in order to monitor genetically modified materials in soy foodstuffs and feeds commercialised in Turkey by multiplex real-time PCR.

    PubMed

    Turkec, Aydin; Kazan, Hande; Baykut, Aykut; Lucas, Stuart J

    2015-01-01

    Soybean is one of the most important biotech crops, widely used as an ingredient in both foodstuffs and feed. DNA extraction methods have been evaluated to detect the presence of genetically modified (GM) materials in soya-containing food and feed products commercialised in Turkey. All extraction methods performed well for the majority of soya foods and feed products analysed. However, the most successful method varied between different products; the Foodproof, Genespin and the cetyltrimethylammonium bromide (CTAB) methods each produced the highest DNA yield and purity for different soya foodstuffs and feeds. Of the samples tested, 20% were positive for the presence of at least two GM elements (35S/NOS) while 11% contained an additional GM element (35S/NOS/FMV). Of the tested products, animal feeds showed a larger prevalence of GM material (50%) than the soya-containing foodstuffs (13%). The best performing extraction methods proved to be the Foodproof, Genespin and CTAB methods for soya-containing food and feed products. The results obtained herein clearly demonstrate the presence of GM soybean in the Turkish market, and that the Foodproof GMO Screening Kit provides reliable screening of soy-containing food and feed products. © 2014 Society of Chemical Industry.

  20. Electrochemical Behavior and Determination of Chlorogenic Acid Based on Multi-Walled Carbon Nanotubes Modified Screen-Printed Electrode

    PubMed Central

    Ma, Xiaoyan; Yang, Hongqiao; Xiong, Huabin; Li, Xiaofen; Gao, Jinting; Gao, Yuntao

    2016-01-01

    In this paper, the multi-walled carbon nanotubes modified screen-printed electrode (MWCNTs/SPE) was prepared and the MWCNTs/SPE was employed for the electrochemical determination of the antioxidant substance chlorogenic acids (CGAs). A pair of well-defined redox peaks of CGA was observed at the MWCNTs/SPE in 0.10 mol/L acetic acid-sodium acetate buffer (pH 6.2) and the electrode process was adsorption-controlled. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods for the determination of CGA were proposed based on the MWCNTs/SPE. Under the optimal conditions, the proposed method exhibited linear ranges from 0.17 to 15.8 µg/mL, and the linear regression equation was Ipa (µA) = 4.1993 C (×10−5 mol/L) + 1.1039 (r = 0.9976) and the detection limit for CGA could reach 0.12 µg/mL. The recovery of matrine was 94.74%–106.65% (RSD = 2.92%) in coffee beans. The proposed method is quick, sensitive, reliable, and can be used for the determination of CGA. PMID:27801797

  1. Materials selection for long life in LEO: A critical evaluation of atomic oxygen testing with thermal atom systems

    NASA Technical Reports Server (NTRS)

    Koontz, S. L.; Kuminecz, J.; Leger, L.; Nordine, P.

    1988-01-01

    The use of thermal atom test methods as a materials selection and screening technique for low-Earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined to be in thermal atom environments are compared to those observed in LEO and in high quality LEO simulations. Reaction efficiencies measured in a new type of thermal atom apparatus are one-hundredth to one-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of 8 in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain specific thermal test environments can be used as reliable materials screening tools. Using thermal atom methods to predict material lifetime in LEO requires direct calibration of the method against LEO data or high quality simulation data for each material.

  2. The reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a German general practice population sample.

    PubMed

    Dybek, Inga; Bischof, Gallus; Grothues, Janina; Reinhardt, Susa; Meyer, Christian; Hapke, Ulfert; John, Ulrich; Broocks, Andreas; Hohagen, Fritz; Rumpf, Hans-Jürgen

    2006-05-01

    Our goal was to analyze the retest reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a primary-care setting and recommend a cut-off value for the different alcohol-related diagnoses. Participants recruited from general practices (GPs) in two northern German cities received the AUDIT, which was embedded in a health-risk questionnaire. In total, 10,803 screenings were conducted. The retest reliability was tested on a subsample of 99 patients, with an intertest interval of 30 days. Sensitivity and specificity at a number of different cut-off values were estimated for the sample of alcohol consumers (n=8237). For this study, 1109 screen-positive patients received a diagnostic interview. Individuals who scored less than five points in the AUDIT and also tested negative in a second alcohol-related screen were defined as "negative" (n=6003). This definition was supported by diagnostic interviews of 99 screen-negative patients from which no false negatives could be detected. As the gold standard for detection of an alcohol-use disorder (AUD), we used the Munich-Composite International Diagnostic Interview (MCIDI), which is based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria. On the item level, the reliability, measured by the intraclass correlation coefficient (ICC), ranged between .39 (Item 9) and .98 (Item 10). For the total score, the ICC was .95. For cut-off values of eight points and five points, 87.5% and 88.9%, respectively, of the AUDIT-positives, and 98.9% and 95.1%, respectively, of the AUDIT-negatives were identically identified at retest, with kappa = .86 and kappa = .81. At the cut-off value of five points, we determined good combinations of sensitivity and specificity for the following diagnoses: alcohol dependence (sensitivity and specificity of .97 and .88, respectively), AUD (.97 and .92), and AUD and/or at-risk consumption (.97 and .91). Embedded in a health-risk questionnaire in primary-care settings, the AUDIT is a reliable and valid screening instrument to identify at-risk drinkers and patients with an AUD. Our findings strongly suggest a lowering of the recommended cut-off value of eight points.

  3. How to Choose Between Measures of Tinnitus Loudness for Clinical Research? A Report on the Reliability and Validity of an Investigator-Administered Test and a Patient-Reported Measure Using Baseline Data Collected in a Phase IIa Drug Trial.

    PubMed

    Hall, Deborah A; Mehta, Rajnikant L; Fackrell, Kathryn

    2017-09-18

    Loudness is a major auditory dimension of tinnitus and is used to diagnose severity, counsel patients, or as a measure of clinical efficacy in audiological research. There is no standard test for tinnitus loudness, but matching and rating methods are popular. This article provides important new knowledge about the reliability and validity of an audiologist-administered tinnitus loudness matching test and a patient-reported tinnitus loudness rating. Retrospective analysis of loudness data for 91 participants with stable subjective tinnitus enrolled in a randomized controlled trial of a novel drug for tinnitus. There were two baseline assessments (screening, Day 1) and a posttreatment assessment (Day 28). About 66%-70% of the variability from screening to Day 1 was attributable to the true score. But measurement error, indicated by the smallest detectable change, was high for both tinnitus loudness matching (20 dB) and tinnitus loudness rating (3.5 units). Only loudness rating captured a sensation that was meaningful to people who lived with the experience of tinnitus. The tinnitus loudness rating performed better against acceptability criteria for reliability and validity than did the tinnitus loudness matching test administered by an audiologist. But the rating question is still limited because it is a single-item instrument and is probably able to detect only large changes (at least 3.5 points).

  4. [Reliability of retinal imaging screening in retinopathy of prematurity].

    PubMed

    Navarro-Blanco, C; Peralta-Calvo, J; Pastora-Salvador, N; Alvarez-Rementería, L; Chamorro, E; Sánchez-Ramos, C

    2014-09-01

    The retinopathy of prematurity (ROP) is a potentially avoidable cause of blindness in children. The advances in neonatal care make the survival of extremely premature infants, who show a greater incidence of the disease, possible. The aim of the study is to evaluate the reliability of ROP screening using retinography imaging with the RetCam 3 wide-angle camera and also study the variability of ROP diagnosis depending on the evaluator. The indirect ophthalmoscopy exam was performed by a Pediatric ROP-Expert Ophthalmologist. The same ophthalmologist and a technician specialized in digital image capture took retinal images using the RetCam 3 wide-angle camera. A total of 30 image sets were analyzed by 3 masked groups: group A (8 ophthalmologists), group B (5 experts in vision), and group C (2 ROP-expert ophthalmologists). According to the diagnosis using indirect ophthalmoscopy, the sensitivity (26-93), Kappa (0.24-0.80), and the percent agreement were statistically significant in group C for the diagnosis of ROP Type 1. In the diagnosis of ROP Type 1+Type 2, Kappa (0.17-0.33) and the percent agreement (58-90) were statistically significant, with higher values in group C. The diagnosis, carried out by ROP-expert ophthalmologists, using the wide-angle camera RetCam 3 has proved to be a reliable method. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  5. Validation of the Identification and Intervention for Dementia in Elderly Africans (IDEA) cognitive screen in Nigeria and Tanzania.

    PubMed

    Paddick, Stella-Maria; Gray, William K; Ogunjimi, Luqman; Lwezuala, Bingileki; Olakehinde, Olaide; Kisoli, Aloyce; Kissima, John; Mbowe, Godfrey; Mkenda, Sarah; Dotchin, Catherine L; Walker, Richard W; Mushi, Declare; Collingwood, Cecilia; Ogunniyi, Adesola

    2015-04-25

    We have previously described the development of the Identification and Intervention for Dementia in Elderly Africans (IDEA) cognitive screen for use in populations with low levels of formal education. The IDEA cognitive screen was developed and field-tested in an elderly, community-based population in rural Tanzania with a relatively high prevalence of cognitive impairment. The aim of this study was to validate the IDEA cognitive screen as an assessment of major cognitive impairment in hospital settings in Nigeria and Tanzania. In Nigeria, 121 consecutive elderly medical clinic outpatients reviewed at the University College Hospital, Ibadan were screened using the IDEA cognitive screen. In Tanzania, 97 consecutive inpatients admitted to Mawenzi Regional Hospital (MRH), Moshi, and 108 consecutive medical clinic outpatients attending the geriatric medicine clinic at MRH were screened. Inter-rater reliability was assessed in Tanzanian outpatients attending St Joseph's Hospital in Moshi using three raters. A diagnosis of dementia or delirium (DSM-IV criteria) was classified as major cognitive impairment and was provided independently by a physician blinded to the results of the screening assessment. The area under the receiver operating characteristic (AUROC) curve in Nigerian outpatients, Tanzanian outpatients and Tanzanian inpatients was 0.990, 0.919 and 0.917 respectively. Inter-rater reliability was good (intra-class correlation coefficient 0.742 to 0.791). In regression models, the cognitive screen did not appear to be educationally biased. The IDEA cognitive screen performed well in these populations and should prove useful in screening for dementia and delirium in other areas of sub-Saharan Africa.

  6. Breast Cancer Screening Beliefs Questionnaire: Psychometric properties assessment of the Arabic version.

    PubMed

    Kwok, Cannas; Endrawes, Gihane; Lee, Chun Fan

    2016-02-01

    The aim of the study was to report the psychometric properties of the Arabic version of the Breast Cancer Screening Beliefs Questionnaire (BCSBQ). A convenience sample of 251 Arabic-Australian women was recruited from a number of Arabic community organizations. Construct validity was examined by Cuzick's non-parametric test while Cronbach α was used to assess internal consistency reliability. Explanatory factor analysis was conducted to study the factor structure. The results indicated that the Arabic version of the BCSBQ had satisfactory validity and internal consistency. The Cronbach's alpha of the three subscales ranged between 0.810 and 0.93. The frequency of breast cancer screening practices (breast awareness, clinical breast-examination and mammography) were significantly associated with attitudes towards general health check-up and perceived barriers to mammographic screening. Exploratory factor analysis showed a similar fit for the hypothesized three-factor structure with our data set. The Arabic version of the BCBSQ is a culturally appropriate, valid and reliable instrument for assessing the beliefs, knowledge and attitudes to breast cancer and breast cancer screening practices among Arabic-Australian women. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Rapid polymerase chain reaction screening of Helicobacter pylori chromosomal point mutations.

    PubMed

    Ge, Z; Taylor, D E

    1997-09-01

    Microdiversity (within individual genes) in the genomes of different Helicobacter pylori strains has been demonstrated to be more frequent than that seen in other prokaryotes. Point mutations in some genes, such as the vacA and 23S ribosomal RNA genes could result in the alteration of pathogenicity or antibiotic susceptibility of individual H. pylori strains. Development of a simple, rapid, and reliable screening method would be useful in the molecular characterization of genetic variation among different H. pylori strains. The copP gene from H. pylori UA802 was used as a model for developing a mutation screening method. Four point mutations were introduced into the copP gene by in vitro site-directed mutagenesis and were verified by DNA sequencing. The mutated copP gene replaced the wild-type locus by natural transformation and homologous recombination. The site-specific mutants were screened by polymerase chain reaction (PCR) using 3'-end mismatched primers. The origins of the PCR fragments were demonstrated by Southern hybridization with the copP-derived DNA probe. Three of these four mutations were characterized by PCR with the specific primers that contained the 3'-terminal nucleotide complementary only to the mutated nucleotide on both plasmid and chromosomal DNA templates. One mutation was able to be identified with the foregoing primer containing an additional wild-type nucleotide at its 3'-end. Point mutant screening with these specific primers offers 100% sensitivity in the aforementioned conditions. To achieve optimal screening, the concentration of magnesium and the annealing temperature have to be adjusted. The procedure reported in this study is a simple, economical, rapid, and efficient approach in the identification of site-specific mutations on both plasmids and chromosomal DNA. Although the method was developed by using a specified H. pylori gene, it can be extended easily to other genes of interest in H. pylori or other organisms.

  8. Gas pressure assisted microliquid-liquid extraction coupled online to direct infusion mass spectrometry: a new automated screening platform for bioanalysis.

    PubMed

    Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas

    2014-10-21

    In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.

  9. A Network-Based Method to Assess the Statistical Significance of Mild Co-Regulation Effects

    PubMed Central

    Horvát, Emőke-Ágnes; Zhang, Jitao David; Uhlmann, Stefan; Sahin, Özgür; Zweig, Katharina Anna

    2013-01-01

    Recent development of high-throughput, multiplexing technology has initiated projects that systematically investigate interactions between two types of components in biological networks, for instance transcription factors and promoter sequences, or microRNAs (miRNAs) and mRNAs. In terms of network biology, such screening approaches primarily attempt to elucidate relations between biological components of two distinct types, which can be represented as edges between nodes in a bipartite graph. However, it is often desirable not only to determine regulatory relationships between nodes of different types, but also to understand the connection patterns of nodes of the same type. Especially interesting is the co-occurrence of two nodes of the same type, i.e., the number of their common neighbours, which current high-throughput screening analysis fails to address. The co-occurrence gives the number of circumstances under which both of the biological components are influenced in the same way. Here we present SICORE, a novel network-based method to detect pairs of nodes with a statistically significant co-occurrence. We first show the stability of the proposed method on artificial data sets: when randomly adding and deleting observations we obtain reliable results even with noise exceeding the expected level in large-scale experiments. Subsequently, we illustrate the viability of the method based on the analysis of a proteomic screening data set to reveal regulatory patterns of human microRNAs targeting proteins in the EGFR-driven cell cycle signalling system. Since statistically significant co-occurrence may indicate functional synergy and the mechanisms underlying canalization, and thus hold promise in drug target identification and therapeutic development, we provide a platform-independent implementation of SICORE with a graphical user interface as a novel tool in the arsenal of high-throughput screening analysis. PMID:24039936

  10. A secondstep in development of a checklist for screening risk for violence in acute psychiatric patients: evaluation of interrater reliability of the Preliminary Scheme 33.

    PubMed

    Bjørkly, Stål; Moger, Tron A

    2007-12-01

    The Acute Project is a research project conducted on acute psychiatric admission wards in Norway. The objective is to develop and validate a structured, easy-to-use screening checklist for assessment of risk for violence in patients both during their stay in the ward and after discharge. The Preliminary Scheme 33 is a 33-item screening checklist with content domain inspired by the Historical-Clinical-Risk Management Scheme (HCR-20), the Brøset Violence Checklist, and eight risk factors extracted from the literature on risk assessment. The Preliminary Scheme 33 was designed and tested in two steps by a research group which includes the authors. The common aim of both steps was to develop this into a time economical, reliable, and valid checklist. In the first step in 2006 the predictive validity of the individual items was tested. The present work presents results from the second step, a study conducted to assess the interrater reliability of the 33 items. Eight clinicians working in an acute psychiatric unit volunteered to be raters and were trained to score the 33 items on a three-point scale in relation to 15 clinical vignettes, which contained information from 15 acute psychiatric patients' files. Analysis showed high interrater reliability for the total score with an intraclass correlation coefficient (ICC) of .86 (95% CI: 0.74-0.94). However, a substantial proportion of the items had medium to low ICCs. Consequences of this finding for further development of these items into a brief screen are discussed.

  11. Interrater reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression - A systematic review and meta-analysis.

    PubMed

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2016-10-01

    Schizoaffective disorder is a common diagnosis in clinical practice but its nosological status has been subject to debate ever since it was conceptualized. Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater reliability. Evidence based on systematic review and meta-analysis methods, however, is lacking. Using a highly sensitive literature search in Medline, Embase, and PsycInfo we identified studies measuring the interrater reliability of schizoaffective disorder in comparison to schizophrenia, bipolar disorder, and unipolar disorder. Out of 4126 records screened we included 25 studies reporting on 7912 patients diagnosed by different raters. The interrater reliability of schizoaffective disorder was moderate (meta-analytic estimate of Cohen's kappa 0.57 [95% CI: 0.41-0.73]), and substantially lower than that of its main differential diagnoses (difference in kappa between 0.22 and 0.19). Although there was considerable heterogeneity, analyses revealed that the interrater reliability of schizoaffective disorder was consistently lower in the overwhelming majority of studies. The results remained robust in subgroup and sensitivity analyses (e.g., diagnostic manual used) as well as in meta-regressions (e.g., publication year) and analyses of publication bias. Clinically, the results highlight the particular importance of diagnostic re-evaluation in patients diagnosed with schizoaffective disorder. They also quantify a widely held clinical impression of lower interrater reliability and agree with earlier meta-analysis reporting low test-retest reliability. Copyright © 2016. Published by Elsevier B.V.

  12. Method-independent, Computationally Frugal Convergence Testing for Sensitivity Analysis Techniques

    NASA Astrophysics Data System (ADS)

    Mai, J.; Tolson, B.

    2017-12-01

    The increasing complexity and runtime of environmental models lead to the current situation that the calibration of all model parameters or the estimation of all of their uncertainty is often computationally infeasible. Hence, techniques to determine the sensitivity of model parameters are used to identify most important parameters. All subsequent model calibrations or uncertainty estimation procedures focus then only on these subsets of parameters and are hence less computational demanding. While the examination of the convergence of calibration and uncertainty methods is state-of-the-art, the convergence of the sensitivity methods is usually not checked. If any, bootstrapping of the sensitivity results is used to determine the reliability of the estimated indexes. Bootstrapping, however, might as well become computationally expensive in case of large model outputs and a high number of bootstraps. We, therefore, present a Model Variable Augmentation (MVA) approach to check the convergence of sensitivity indexes without performing any additional model run. This technique is method- and model-independent. It can be applied either during the sensitivity analysis (SA) or afterwards. The latter case enables the checking of already processed sensitivity indexes. To demonstrate the method's independency of the convergence testing method, we applied it to two widely used, global SA methods: the screening method known as Morris method or Elementary Effects (Morris 1991) and the variance-based Sobol' method (Solbol' 1993). The new convergence testing method is first scrutinized using 12 analytical benchmark functions (Cuntz & Mai et al. 2015) where the true indexes of aforementioned three methods are known. This proof of principle shows that the method reliably determines the uncertainty of the SA results when different budgets are used for the SA. The results show that the new frugal method is able to test the convergence and therefore the reliability of SA results in an efficient way. The appealing feature of this new technique is the necessity of no further model evaluation and therefore enables checking of already processed sensitivity results. This is one step towards reliable and transferable, published sensitivity results.

  13. DG-AMMOS: a new tool to generate 3d conformation of small molecules using distance geometry and automated molecular mechanics optimization for in silico screening.

    PubMed

    Lagorce, David; Pencheva, Tania; Villoutreix, Bruno O; Miteva, Maria A

    2009-11-13

    Discovery of new bioactive molecules that could enter drug discovery programs or that could serve as chemical probes is a very complex and costly endeavor. Structure-based and ligand-based in silico screening approaches are nowadays extensively used to complement experimental screening approaches in order to increase the effectiveness of the process and facilitating the screening of thousands or millions of small molecules against a biomolecular target. Both in silico screening methods require as input a suitable chemical compound collection and most often the 3D structure of the small molecules has to be generated since compounds are usually delivered in 1D SMILES, CANSMILES or in 2D SDF formats. Here, we describe the new open source program DG-AMMOS which allows the generation of the 3D conformation of small molecules using Distance Geometry and their energy minimization via Automated Molecular Mechanics Optimization. The program is validated on the Astex dataset, the ChemBridge Diversity database and on a number of small molecules with known crystal structures extracted from the Cambridge Structural Database. A comparison with the free program Balloon and the well-known commercial program Omega generating the 3D of small molecules is carried out. The results show that the new free program DG-AMMOS is a very efficient 3D structure generator engine. DG-AMMOS provides fast, automated and reliable access to the generation of 3D conformation of small molecules and facilitates the preparation of a compound collection prior to high-throughput virtual screening computations. The validation of DG-AMMOS on several different datasets proves that generated structures are generally of equal quality or sometimes better than structures obtained by other tested methods.

  14. The reliability of in-hospital diagnoses of diabetes mellitus in the setting of an acute myocardial infarction.

    PubMed

    Arnold, Suzanne V; Lipska, Kasia J; Inzucchi, Silvio E; Li, Yan; Jones, Philip G; McGuire, Darren K; Goyal, Abhinav; Stolker, Joshua M; Lind, Marcus; Spertus, John A; Kosiborod, Mikhail

    2014-01-01

    Incident diabetes mellitus (DM) is important to recognize in patients with acute myocardial infarction (AMI). To develop an efficient screening strategy, we explored the use of random plasma glucose (RPG) at admission and fasting plasma glucose (FPG) to select patients with AMI for glycosylated hemoglobin (HbA1c) testing. Prospective registry of 1574 patients with AMI not taking glucose-lowering medication from 24 US hospitals. All patients had HbA1c measured at a core laboratory and admission RPG and ≥2 FPGs recorded during hospitalization. We examined potential combinations of RPG and FPG and compared these with HbA1c≥6.5%-considered the gold standard for DM diagnosis in these analyses. An RPG>140 mg/dL or FPG≥126 mg/dL had high sensitivity for DM diagnosis. Combining these into a screening protocol (if admission RPG>140, check HbA1c; or if FPG≥126 on a subsequent day, check HbA1c) led to HbA1c testing in 50% of patients and identified 86% with incident DM (number needed to screen (NNS)=3.3 to identify 1 case of DM; vs NNS=5.6 with universal HbA1c screening). Alternatively, using an RPG>180 led to HbA1c testing in 40% of patients with AMI and identified 82% of DM (NNS=2.7). We have established two potential selective screening methods for DM in the setting of AMI that could identify the vast majority of incident DM by targeted screening of 40-50% of patients with AMI with HbA1c testing. Using these methods may efficiently identify patients with AMI with DM so that appropriate education and treatment can be promptly initiated.

  15. Global Sensitivity Analysis of Environmental Models: Convergence, Robustness and Validation

    NASA Astrophysics Data System (ADS)

    Sarrazin, Fanny; Pianosi, Francesca; Khorashadi Zadeh, Farkhondeh; Van Griensven, Ann; Wagener, Thorsten

    2015-04-01

    Global Sensitivity Analysis aims to characterize the impact that variations in model input factors (e.g. the parameters) have on the model output (e.g. simulated streamflow). In sampling-based Global Sensitivity Analysis, the sample size has to be chosen carefully in order to obtain reliable sensitivity estimates while spending computational resources efficiently. Furthermore, insensitive parameters are typically identified through the definition of a screening threshold: the theoretical value of their sensitivity index is zero but in a sampling-base framework they regularly take non-zero values. There is little guidance available for these two steps in environmental modelling though. The objective of the present study is to support modellers in making appropriate choices, regarding both sample size and screening threshold, so that a robust sensitivity analysis can be implemented. We performed sensitivity analysis for the parameters of three hydrological models with increasing level of complexity (Hymod, HBV and SWAT), and tested three widely used sensitivity analysis methods (Elementary Effect Test or method of Morris, Regional Sensitivity Analysis, and Variance-Based Sensitivity Analysis). We defined criteria based on a bootstrap approach to assess three different types of convergence: the convergence of the value of the sensitivity indices, of the ranking (the ordering among the parameters) and of the screening (the identification of the insensitive parameters). We investigated the screening threshold through the definition of a validation procedure. The results showed that full convergence of the value of the sensitivity indices is not necessarily needed to rank or to screen the model input factors. Furthermore, typical values of the sample sizes that are reported in the literature can be well below the sample sizes that actually ensure convergence of ranking and screening.

  16. Integrated and global pseudotargeted metabolomics strategy applied to screening for quality control markers of Citrus TCMs.

    PubMed

    Shu, Yisong; Liu, Zhenli; Zhao, Siyu; Song, Zhiqian; He, Dan; Wang, Menglei; Zeng, Honglian; Lu, Cheng; Lu, Aiping; Liu, Yuanyan

    2017-08-01

    Traditional Chinese medicine (TCM) exerts its therapeutic effect in a holistic fashion with the synergistic function of multiple characteristic constituents. The holism philosophy of TCM is coincident with global and systematic theories of metabolomics. The proposed pseudotargeted metabolomics methodologies were employed for the establishment of reliable quality control markers for use in the screening strategy of TCMs. Pseudotargeted metabolomics integrates the advantages of both targeted and untargeted methods. In the present study, targeted metabolomics equipped with the gold standard RRLC-QqQ-MS method was employed for in vivo quantitative plasma pharmacochemistry study of characteristic prototypic constituents. Meanwhile, untargeted metabolomics using UHPLC-QE Orbitrap HRMS with better specificity and selectivity was employed for identification of untargeted metabolites in the complex plasma matrix. In all, 32 prototypic metabolites were quantitatively determined, and 66 biotransformed metabolites were convincingly identified after being orally administered with standard extracts of four labeled Citrus TCMs. The global absorption and metabolism process of complex TCMs was depicted in a systematic manner.

  17. High-throughput technology for novel SO2 oxidation catalysts

    PubMed Central

    Loskyll, Jonas; Stoewe, Klaus; Maier, Wilhelm F

    2011-01-01

    We review the state of the art and explain the need for better SO2 oxidation catalysts for the production of sulfuric acid. A high-throughput technology has been developed for the study of potential catalysts in the oxidation of SO2 to SO3. High-throughput methods are reviewed and the problems encountered with their adaptation to the corrosive conditions of SO2 oxidation are described. We show that while emissivity-corrected infrared thermography (ecIRT) can be used for primary screening, it is prone to errors because of the large variations in the emissivity of the catalyst surface. UV-visible (UV-Vis) spectrometry was selected instead as a reliable analysis method of monitoring the SO2 conversion. Installing plain sugar absorbents at reactor outlets proved valuable for the detection and quantitative removal of SO3 from the product gas before the UV-Vis analysis. We also overview some elements used for prescreening and those remaining after the screening of the first catalyst generations. PMID:27877427

  18. Segmentation algorithm of colon based on multi-slice CT colonography

    NASA Astrophysics Data System (ADS)

    Hu, Yizhong; Ahamed, Mohammed Shabbir; Takahashi, Eiji; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Suzuki, Masahiro; Iinuma, Gen; Moriyama, Noriyuki

    2012-02-01

    CT colonography is a radiology test that looks at people's large intestines(colon). CT colonography can screen many options of colon cancer. This test is used to detect polyps or cancers of the colon. CT colonography is safe and reliable. It can be used if people are too sick to undergo other forms of colon cancer screening. In our research, we proposed a method for automatic segmentation of the colon from abdominal computed Tomography (CT) images. Our multistage detection method extracted colon and spited colon into different parts according to the colon anatomy information. We found that among the five segmented parts of the colon, sigmoid (20%) and rectum (50%) are more sensitive toward polyps and masses than the other three parts. Our research focused on detecting the colon by the individual diagnosis of sigmoid and rectum. We think it would make the rapid and easy diagnosis of colon in its earlier stage and help doctors for analysis of correct position of each part and detect the colon rectal cancer much easier.

  19. Screening for elevated levels of fear-avoidance beliefs regarding work or physical activities in people receiving outpatient therapy.

    PubMed

    Hart, Dennis L; Werneke, Mark W; George, Steven Z; Matheson, James W; Wang, Ying-Chih; Cook, Karon F; Mioduski, Jerome E; Choi, Seung W

    2009-08-01

    Screening people for elevated levels of fear-avoidance beliefs is uncommon, but elevated levels of fear could worsen outcomes. Developing short screening tools might reduce the data collection burden and facilitate screening, which could prompt further testing or management strategy modifications to improve outcomes. The purpose of this study was to develop efficient yet accurate screening methods for identifying elevated levels of fear-avoidance beliefs regarding work or physical activities in people receiving outpatient rehabilitation. A secondary analysis of data collected prospectively from people with a variety of common neuromusculoskeletal diagnoses was conducted. Intake Fear-Avoidance Beliefs Questionnaire (FABQ) data were collected from 17,804 people who had common neuromusculoskeletal conditions and were receiving outpatient rehabilitation in 121 clinics in 26 states (in the United States). Item response theory (IRT) methods were used to analyze the FABQ data, with particular emphasis on differential item functioning among clinically logical groups of subjects, and to identify screening items. The accuracy of screening items for identifying subjects with elevated levels of fear was assessed with receiver operating characteristic analyses. Three items for fear of physical activities and 10 items for fear of work activities represented unidimensional scales with adequate IRT model fit. Differential item functioning was negligible for variables known to affect functional status outcomes: sex, age, symptom acuity, surgical history, pain intensity, condition severity, and impairment. Items that provided maximum information at the median for the FABQ scales were selected as screening items to dichotomize subjects by high versus low levels of fear. The accuracy of the screening items was supported for both scales. This study represents a retrospective analysis, which should be replicated using prospective designs. Future prospective studies should assess the reliability and validity of using one FABQ item to screen people for high levels of fear-avoidance beliefs. The lack of differential item functioning in the FABQ scales in the sample tested in this study suggested that FABQ screening could be useful in routine clinical practice and allowed the development of single-item screening for fear-avoidance beliefs that accurately identified subjects with elevated levels of fear. Because screening was accurate and efficient, single IRT-based FABQ screening items are recommended to facilitate improved evaluation and care of heterogeneous populations of people receiving outpatient rehabilitation.

  20. A study of characteristics of a reliable and practical breath alcohol screening test. Part A

    DOT National Transportation Integrated Search

    1975-08-01

    The objectives of this study were (1) to investigate several commercially available breath-alcohol screening test devices of the length-of-stain type, under standardized laboratory conditions, with respect to their ability satisfactorily to detect an...

  1. Test-retest reliability and practice effects of a rapid screen of mild traumatic brain injury.

    PubMed

    De Monte, Veronica Eileen; Geffen, Gina Malke; Kwapil, Karleigh

    2005-07-01

    Test-retest reliabilities and practice effects of measures from the Rapid Screen of Concussion (RSC), in addition to the Digit Symbol Substitution Test (Digit Symbol), were examined. Twenty five male participants were tested three times; each testing session scheduled a week apart. The test-retest reliability estimates for most measures were reasonably good, ranging from .79 to .97. An exception was the delayed word recall test, which has had a reliability estimate of .66 for the first retest, and .59 for the second retest. Practice effects were evident from Times 1 to 2 on the sentence comprehension and delayed recall subtests of the RSC, Digit Symbol and a composite score. There was also a practice effect of the same magnitude found from Time 2 to Time 3 on Digit Symbol, delayed recall and the composite score. Statistics on measures for both the first and second retest intervals, with associated practice effects, are presented to enable the calculation of reliable change indices (RCI). The RCI may be used to assess any improvement in cognitive functioning after mild Traumatic Brain Injury.

  2. Defining physicians' readiness to screen and manage intimate partner violence in Greek primary care settings.

    PubMed

    Papadakaki, Maria; Prokopiadou, Dimitra; Petridou, Eleni; Kogevinas, Manolis; Lionis, Christos

    2012-06-01

    The current article aims to translate the PREMIS (Physician Readiness to Manage Intimate Partner Violence) survey into the Greek language and test its validity and reliability in a sample of primary care physicians. The validation study was conducted in 2010 and involved all the general practitioners serving two adjacent prefectures of Greece (n = 80). Maximum-likelihood factor analysis (MLF) was used to extract key survey factors. The instrument was further assessed for the following psychometric properties: (a) scale reliability, (b) item-specific reliability, (c) test-retest reliability, (d) scale construct validity, and (e) internal predictive validity. The MLF analysis of 23 opinion items revealed a seven-factor solution (preparation, constraint, workplace issues, screening, self-efficacy, alcohol/drugs, victim understanding), which was statistically sound (p = .293). Most of the newly derived scales displayed satisfactory internal consistency (α ≥ .60), high item-specific reliability, strong construct, and internal predictive validity (F = 2.82; p = .004), and high repeatability when retested with 20 individuals (intraclass correlation coefficient [ICC] > .70). The tool was found appropriate to facilitate the identification of competence deficits and the evaluation of training initiatives.

  3. Reliability and Validity of a Smartphone-Paired Pulse Oximeter for Screening of Critical Congenital Heart Defects in Newborns.

    PubMed

    Huizing, Maurice J; Villamor-Martínez, Eduardo; Chavagne, Ingrid A; Vanagt, Ward Y; Spaanderman, Marc A E; Villamor, Eduardo

    2017-01-01

    Barriers to widespread implementation of pulse oximetry screening of critical congenital heart defects (CCHD) in newborns include increasing trends of out-of-hospital births and cost of equipment. In recent years, smartphone-compatible pulse oximeters have appeared on the market, but the validity of such devices in the setting of CCHD screening has not been evaluated. To compare the performance in CCHD screening of a smartphone-paired pulse oximeter (Masimo iSpO2-Rx™) and a hospital-grade pulse oximeter (Masimo Radical-7™). Preductal (right hand) and postductal (either foot) saturations were determined in a population of 201 term newborns by 2 independent teams, one using the Radical-7 and the other using the iSpO2-Rx. Bland-Altman analysis was applied to calculate mean bias and 95% limits of agreement between the 2 pulse oximeters. For the preductal oxygen saturation, the mean bias (Radical-7 minus iSpO2-Rx) was -0.08 (SD 1.76) and the lower and upper limits of agreement were -3.52 and 3.36, respectively. For the postductal oxygen saturation, the mean bias was -0.11 (SD 1.68) and the lower and upper limits of agreement were -3.49 and 3.18, respectively. In addition, the iSpO2-Rx provided reliable measurements of saturations below 95% in a group of 12 infants admitted to the neonatal intensive care unit. Our data suggest that CCHD screening with the Masimo iSpO2-Rx is feasible and accurate. The use of reliable smartphone-paired pulse oximeters may contribute to the extension of CCHD screening to home births and low resource settings. © 2017 S. Karger AG, Basel.

  4. A cultural research approach to instrument development: the case of breast and cervical cancer screening among Latino and Anglo women

    PubMed Central

    Betancourt, Hector; Flynn, Patricia M.; Riggs, Matt; Garberoglio, Carlos

    2010-01-01

    To illustrate the implementation of a bottom-up approach to the study of culture in health disparities, this article describes the development of a cultural cancer screening scale (CCSS) using mixed methodologies. The aim was to identify cultural factors relevant to breast and cervical cancer screening, develop an instrument to assess them and examine its preliminary psychometric properties among Latin American (Latino) and non-Latino White (Anglo) women in Southern California. Seventy-eight Latino and Anglo women participated in semi-structured interviews, which were content coded based on Triandis' methods for the analysis of subjective culture. Based on the emerging cultural elements, items relevant to cancer screening were developed and pilot tested with 161 participants. After the instrument was refined, 314 Latino and Anglo women from various socioeconomic backgrounds completed the CCSS and data were factor analyzed resulting in five cultural factors: cancer screening fatalism, negative beliefs about health professionals, catastrophic disease expectations, symptomatic deterrents and sociocultural deterrents. The instrument demonstrated measurement equivalence, adequate reliability and predictive validity. The research and the CCSS are discussed in terms of implications for the study of culture in relation to health disparities and the development of evidence-based interventions with culturally diverse populations and their health professionals. PMID:20864605

  5. Initial Evidence for the Reliability and Validity of the Student Risk Screening Scale for Internalizing and Externalizing Behaviors at the Middle School Level

    ERIC Educational Resources Information Center

    Lane, Kathleen Lynne; Oakes, Wendy Peia; Carter, Erik W.; Lambert, Warren E.; Jenkins, Abbie B.

    2013-01-01

    We reported findings of an exploratory validation study of a revised universal screening instrument: the Student Risk Screening Scale--Internalizing and Externalizing (SRSS-IE) for use with middle school students. Tested initially for use with elementary-age students, the SRSS-IE was adapted to include seven additional items reflecting…

  6. A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.

    2016-01-01

    Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

  7. Setup of a Protocol of Molecular Diagnosis of β-Thalassemia Mutations in Tunisia using Denaturing High-Performance Liquid Chromatography (DHPLC).

    PubMed

    Sahli, Chaima Abdelhafidh; Ben Salem, Ikbel; Jouini, Latifa; Laouini, Naouel; Dabboubi, Rym; Hadj Fredj, Sondes; Siala, Hajer; Othmeni, Rym; Dakhlaoui, Boutheina; Fattoum, Slaheddine; Bibi, Amina; Messaoud, Taieb

    2016-09-01

    β-Thalassemia is one of the most prevalent worldwide autosomal recessive disorders. It presents a great molecular heterogeneity resulting from more than 200 causative mutations in the β-globin gene. In Tunisia, β-thalassemia represents the most prevalent monogenic hemoglobin disorder with 2.21% of carriers. Efficient and reliable mutation-screening methods are essential in order to establish appropriate prevention programs for at risk couples. The aim of the present study is to develop an efficient method based on the denaturing high-performance liquid chromatography (DHPLC) in which the whole β-globin gene (HBB) is screened for mutations covering about 90% of the spectrum. We have performed the validation of a DHPLC assay for direct genotyping of 11 known β-thalassemia mutations in the Tunisian population. DHPLC assay was established based on the analysis of 62 archival β-thalassemia samples previously genotyped then validated with full concordance on 50 tests with blind randomized samples previously genotyped with DNA sequencing and with 96% of consistency on 40 samples as a prospective study. Compared to other genotyping techniques, the DHPLC method can meet the requirements of direct genotyping of known β-thalassemia mutations in Tunisia and to be applied as a powerful tool for the genetic screening of prenatal and postnatal individuals. © 2016 Wiley Periodicals, Inc.

  8. New method of paired thyrotropin assay as a screening test for neonatal hypothyroidism. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyai, K.; Oura, T.; Kawashima, M.

    1978-11-01

    A simple and reliable method of paired TSH assay was developed and used in screening for neonatal primary hypothyroidism. In this method, a paired assay is first done. Equal parts of the extracts of dried blood spots on filter paper (9 mm diameter) from two infants 4 to 7 days old are combined and assayed for TSH by double antibody RIA. If the value obtained is over the cut-off point, the extracts are assayed separately for TSH in a second assay to identify the abnormal sample. Two systems, A and B, with different cut-off points were tested. On the basismore » of reference blood samples (serum levels of TSH, 80 ..mu..U/ml in system A and 40 ..mu..U/ml in system B), the cut-off point was selected as follows: upper 5 (A) or 4 (B) percentile in the paired assay and values of reference blood samples in the second individual assay. Four cases (2 in A and 2 in B) of neonatal primary hypothyroidism were found among 25 infants (23 in A and 2 in B) who were recalled from a general population of 41,400 infants (24,200 in A and 17,200 in B) by 22,700 assays. This paired TSH assay system saves labor and expense for screening neonatal hypothyroidism.« less

  9. Direct screening of ground water samples for fuel oxygenates by headspace liquid phase microextraction-gas chromatography.

    PubMed

    Kaykhaii, Massoud; Mirbaloochzahi, Mohammad Reza

    2008-12-01

    The applicability of the headspace liquid phase microextraction and gas chromatography (HS-LPME/GC) for the expeditious and reliable screening of 68 well water samples for selected fuel oxygenates compounds, viz. methyl tertiary-butyl ether (MTBE), tertiary-amyl methyl ether (TAME), ethyl tertiary-butyl ether (ETBE) and n-butyl ethyl ether (n-BEE) has been evaluated. The method used 3 microl of 1:1 benzyl alcohol/1-octanol as extraction solvent, 20 min extraction time with stirring at 1,250 rpm, at 20 degrees C and salt addition of a mixture of 0.3 g ml(-1) sodium sulphate/0.1 g ml(-1) sodium chloride. The enrichment factors of this method were from 171 to 571. Limits of detection were in the range of 77-110 ng l(-1). The relative standard deviations (RSDs) at 0.05, 0.50 and 10.0 mg l(-1) of spiking levels were in the range of 1.28-6.80% with recoveries between 96.2 and 106.0%. Sixty-eight groundwater wells that were located near different gasoline reservoirs in eight largest cities of the Sistan and Balouchestan province were screened by the method. Eight contaminated wells were identified contained MTBE at levels between 0.3 and 1.7 mg l(-1). In all cases, other target analytes were at low concentrations or not detected.

  10. High- and low-throughput scoring of fat mass and body fat distribution in C. elegans

    PubMed Central

    Wählby, Carolina; Lee-Conery, Annie; Bray, Mark-Anthony; Kamentsky, Lee; Larkins-Ford, Jonah; Sokolnicki, Katherine L.; Veneskey, Matthew; Michaels, Kerry; Carpenter, Anne E.; O’Rourke, Eyleen J.

    2014-01-01

    Fat accumulation is a complex phenotype affected by factors such as neuroendocrine signaling, feeding, activity, and reproductive output. Accordingly, the most informative screens for genes and compounds affecting fat accumulation would be those carried out in whole living animals. Caenorhabditis elegans is a well-established and effective model organism, especially for biological processes that involve organ systems and multicellular interactions, such as metabolism. Every cell in the transparent body of C. elegans is visible under a light microscope. Consequently, an accessible and reliable method to visualize worm lipid-droplet fat depots would make C. elegans the only metazoan in which genes affecting not only fat mass but also body fat distribution could be assessed at a genome-wide scale. Here we present a radical improvement in oil red O worm staining together with high-throughput image-based phenotyping. The three-step sample preparation method is robust, formaldehyde-free, and inexpensive, and requires only 15 minutes of hands-on time to process a 96-well plate. Together with our free and user-friendly automated image analysis package, this method enables C. elegans sample preparation and phenotype scoring at a scale that is compatible with genome-wide screens. Thus we present a feasible approach to small-scale phenotyping and large-scale screening for genetic and/or chemical perturbations that lead to alterations in fat quantity and distribution in whole animals. PMID:24784529

  11. Evaluation of a Screening System for Obesogenic Compounds: Screening of Endocrine Disrupting Compounds and Evaluation of the PPAR Dependency of the Effect

    PubMed Central

    Pereira-Fernandes, Anna; Demaegdt, Heidi; Vandermeiren, Karine; Hectors, Tine L. M.; Jorens, Philippe G.; Blust, Ronny; Vanparys, Caroline

    2013-01-01

    Recently the environmental obesogen hypothesis has been formulated, proposing a role for endocrine disrupting compounds (EDCs) in the development of obesity. To evaluate this hypothesis, a screening system for obesogenic compounds is urgently needed. In this study, we suggest a standardised protocol for obesogen screening based on the 3T3-L1 cell line, a well-characterised adipogenesis model, and direct fluorescent measurement using Nile red lipid staining technique. In a first phase, we characterised the assay using the acknowledged obesogens rosiglitazone and tributyltin. Based on the obtained dose-response curves for these model compounds, a lipid accumulation threshold value was calculated to ensure the biological relevance and reliability of statistically significant effects. This threshold based method was combined with the well described strictly standardized mean difference (SSMD) method for classification of non-, weak- or strong obesogenic compounds. In the next step, a range of EDCs, used in personal and household care products (parabens, musks, phthalates and alkylphenol compounds), were tested to further evaluate the obesogenicity screening assay for its discriminative power and sensitivity. Additionally, the peroxisome proliferator activated receptor γ (PPARγ) dependency of the positive compounds was evaluated using PPARγ activation and antagonist experiments. Our results showed the adipogenic potential of all tested parabens, several musks and phthalate compounds and bisphenol A (BPA). PPARγ activation was associated with adipogenesis for parabens, phthalates and BPA, however not required for obesogenic effects induced by Tonalide, indicating the role of other obesogenic mechanisms for this compound. PMID:24155963

  12. A simple, fast and cheap non-SPE screening method for antibacterial residue analysis in milk and liver using liquid chromatography-tandem mass spectrometry.

    PubMed

    Martins, Magda Targa; Melo, Jéssica; Barreto, Fabiano; Hoff, Rodrigo Barcellos; Jank, Louise; Bittencourt, Michele Soares; Arsand, Juliana Bazzan; Schapoval, Elfrides Eva Scherman

    2014-11-01

    In routine laboratory work, screening methods for multiclass analysis can process a large number of samples in a short time. The main challenge is to develop a methodology to detect as many different classes of residues as possible, combined with speed and low cost. An efficient technique for the analysis of multiclass antibacterial residues (fluoroquinolones, tetracyclines, sulfonamides and trimethoprim) was developed based on simple, environment-friendly extraction for bovine milk, cattle and poultry liver. Acidified ethanol was used as an extracting solvent for milk samples. Liver samples were treated using EDTA-washed sand for cell disruption, methanol:water and acidified acetonitrile as extracting solvent. A total of 24 antibacterial residues were detected and confirmed using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), at levels between 10, 25 and 50% of the maximum residue limit (MRL). For liver samples a metabolite (sulfaquinoxaline-OH) was also monitored. A validation procedure was conducted for screening purposes in accordance with European Union requirements (2002/657/EC). The detection capability (CCβ) false compliant rate was less than 5% at the lowest level for each residue. Specificity and ruggedness were also discussed. Incurred and routine samples were analyzed and the method was successfully applied. The results proved that this method can be an important tool in routine analysis, since it is very fast and reliable. Copyright © 2014. Published by Elsevier B.V.

  13. Online screening of nitric oxide scavengers in natural products using high performance liquid chromatography coupled with tandem diode array and fluorescence detection.

    PubMed

    Li, Dapeng; Wang, Ting; Guo, Yujie; Hu, Yuanjia; Yu, Boyang; Qi, Jin

    2015-12-18

    Nitric oxide (NO) is an important cellular signaling molecule with extensive physiological and pathophysiological effects. NO scavengers have the potential to treat inflammation, septic shock and other related diseases, and numerous examples have been chemically synthesized or isolated from natural products. The chemical diversity of natural products, however, means that a huge effort is necessary to efficiently screen and identify bioactive compounds, especially NO scavengers. In this article, we propose an effective analytical method to screen for NO scavengers in three natural products using an online system that couples high performance liquid chromatography with tandem diode array and fluorescence detection (HPLC-DAD-FLD). Eighteen compounds from radix of Scutellaria baicalensis Georgi and green tea displayed significant NO scavenging activity whereas components of Pueraria lobata (Willd.) Ohwi had no discernable activity. The structures of the active compounds were elucidated using Agilent Accurate-Mass Q-TOF LC/MS system. Preliminary analysis of structure-activity relationships indicated that, in flavonoids, a 2,3-double bond and a 3-H atom or a 3-OH group are essential for activity. In tannins, poly-hydroxyl groups are important for NO scavenging activity. Method validation indicated that the newly developed method is both reliable and repeatable. The online method that we present provides a simple, rapid and effective way to identify and characterize NO scavengers present in natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Rapid and simple immunochemical screening combined with hand-shaking extraction for thiamethoxam residue in agricultural products.

    PubMed

    Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro

    2013-06-01

    With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.

  15. Development of the multiple sclerosis (MS) early mobility impairment questionnaire (EMIQ).

    PubMed

    Ziemssen, Tjalf; Phillips, Glenn; Shah, Ruchit; Mathias, Adam; Foley, Catherine; Coon, Cheryl; Sen, Rohini; Lee, Andrew; Agarwal, Sonalee

    2016-10-01

    The Early Mobility Impairment Questionnaire (EMIQ) was developed to facilitate early identification of mobility impairments in multiple sclerosis (MS) patients. We describe the initial development of the EMIQ with a focus on the psychometric evaluation of the questionnaire using classical and item response theory methods. The initial 20-item EMIQ was constructed by clinical specialists and qualitatively tested among people with MS and physicians via cognitive interviews. Data from an observational study was used to make additional updates to the instrument based on exploratory factor analysis (EFA) and item response theory (IRT) analysis, and psychometric analyses were performed to evaluate the reliability and validity of the final instrument's scores and screening properties (i.e., sensitivity and specificity). Based on qualitative interview analyses, a revised 15-item EMIQ was included in the observational study. EFA, IRT and item-to-item correlation analyses revealed redundant items which were removed leading to the final nine-item EMIQ. The nine-item EMIQ performed well with respect to: test-retest reliability (ICC = 0.858); internal consistency (α = 0.893); convergent validity; and known-groups methods for construct validity. A cut-point of 41 on the 0-to-100 scale resulted in sufficient sensitivity and specificity statistics for viably identifying patients with mobility impairment. The EMIQ is a content valid and psychometrically sound instrument for capturing MS patients' experience with mobility impairments in a clinical practice setting. Additional research is suggested to further confirm the EMIQ's screening properties over time.

  16. Sex chromosomal abnormalities associated with equine infertility: validation of a simple molecular screening tool in the Purebred Spanish Horse.

    PubMed

    Anaya, G; Molina, A; Valera, M; Moreno-Millán, M; Azor, P; Peral-García, P; Demyda-Peyrás, S

    2017-08-01

    Chromosomal abnormalities in the sex chromosome pair (ECAX and ECAY) are widely associated with reproductive problems in horses. However, a large proportion of these abnormalities remains undiagnosed due to the lack of an affordable diagnostic tool that allows for avoiding karyotyping tests. Hereby, we developed an STR (single-tandem-repeat)-based molecular method to determine the presence of the main sex chromosomal abnormalities in horses in a fast, cheap and reliable way. The frequency of five ECAX-linked (LEX026, LEX003, TKY38, TKY270 and UCDEQ502) and two ECAY-linked (EcaYH12 and SRY) markers was characterized in 261 Purebred Spanish Horses to determine the efficiency of the methodology developed to be used as a chromosomal diagnostic tool. All the microsatellites analyzed were highly polymorphic, with a sizeable number of alleles (polymorphic information content > 0.5). Based on this variability, the methodology showed 100% sensitivity and 99.82% specificity to detect the most important sex chromosomal abnormalities reported in horses (chimerism, Turner's syndrome and sex reversal syndromes). The method was also validated with 100% efficiency in 10 individuals previously diagnosed as chromosomally aberrant. This STR screening panel is an efficient and reliable molecular-cytogenetic tool for the early detection of sex chromosomal abnormalities in equines that could be included in breeding programs to save money, effort and time of veterinary practitioners and breeders. © 2017 Stichting International Foundation for Animal Genetics.

  17. A rapid and reliable method for Pb isotopic analysis of peat and lichens by laser ablation-quadrupole-inductively coupled plasma-mass spectrometry for biomonitoring and sample screening.

    PubMed

    Kylander, M E; Weiss, D J; Jeffries, T E; Kober, B; Dolgopolova, A; Garcia-Sanchez, R; Coles, B J

    2007-01-16

    An analytical protocol for rapid and reliable laser ablation-quadrupole (LA-Q)- and multi-collector (MC-) inductively coupled plasma-mass spectrometry (ICP-MS) analysis of Pb isotope ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb) in peats and lichens is developed. This technique is applicable to source tracing atmospheric Pb deposition in biomonitoring studies and sample screening. Reference materials and environmental samples were dry ashed and pressed into pellets for introduction by laser ablation. No binder was used to reduce contamination. LA-MC-ICP-MS internal and external precisions were <1.1% and <0.3%, respectively, on both (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios. LA-Q-ICP-MS internal precisions on (207)Pb/(206)Pb and (208)Pb/(206)Pb ratios were lower with values for the different sample sets <14.3% while external precisions were <2.9%. The level of external precision acquired in this study is high enough to distinguish between most modern Pb sources. LA-MC-ICP-MS measurements differed from thermal ionisation mass spectrometry (TIMS) values by 1% or less while the accuracy obtained using LA-Q-ICP-MS compared to solution MC-ICP-MS was 3.1% or better using a run bracketing (RB) mass bias correction method. Sample heterogeneity and detector switching when measuring (208)Pb by Q-ICP-MS are identified as sources of reduced analytical performance.

  18. 14 CFR 1214.504 - Screening requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... meaning of this subsection. (iii) All information obtained by medical or Employee Assistance Program... Critical Space System Personnel Reliability Program § 1214.504 Screening requirements. (a) Only those... program. 4 See footnote 1 to § 1214.502(e). (b) Determination of suitability for assignment to mission...

  19. e-HCL-32: a useful, valid and user friendly tool in the screening of bipolar II disorder.

    PubMed

    Hidalgo-Mazzei, Diego; Mateu, Ainoa; Undurraga, Juan; Rosa, Adriane R; Pacchiarotti, Isabella; Bonnin, Caterina del Mar; Sánchez-Moreno, José; Colom, Francesc; Vieta, Eduard

    2015-01-01

    Bipolar type II (BDII) is a frequent disorder with high morbidity and mortality, characterized by depressive and hypomanic episodes. Early diagnosis can be effective in improving long-term prognosis. However, diagnosing BDII is challenging due to the difficulty in detecting past hypomanic episodes. The HCL-32 is a widely used and reliable screening instrument for the detection of past hypomanic episodes. Making this tool available to more patients could help diagnose and treat undetected cases of BDII earlier. New technologies such as the Internet have been previously used for this purpose with favorable outcomes. Accordingly, the objective of this study is to evaluate the acceptability, validity, reliability and equivalence of an online version of this questionnaire. From May 2012 to March 2013, 52 participants attending an outpatient mental health clinic completed a paper version of the HCL-32 (HCL-32) and its online version (e-HCL-32) within two weeks. After its completion, they were asked to answer a brief satisfaction survey. No differences were found (HCL-32 mean total score=17.73 (SD=7.37), e-HCL-32 mean total score=18.28 (SD=7.09). T=-1.720, p=0.092, 95% CI=-1.21 to 0.09) between the results of the paper and pencil HCL-32 compared to its online version (e-HCL-32). The psychometric properties of the online version of the hypomania checklist (e-HCL-32) were good and comparable to the paper and pencil version. 80% of participants found online questionnaires to be easier to answer and more user-friendly. The results of this study support the use of an online screening tool for the detection of previous hypomanic episodes (necessary for BDII diagnosis) as it showed to have a similar validity and reliability to the traditional paper and pencil method. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Screening utility of the social anxiety screening scale in Spanish speaking adolescents.

    PubMed

    Piqueras, José Antonio; Olivares, José; Hidalgo, María Dolores

    2012-07-01

    The aim of this study was to analyse the screening utility of the Social Anxiety Screening Scale (SASS/EDAS) in a sample of 227 adolescents with social anxiety disorder and 156 Without it (14-17 years). Results showed that the EDAS subscales (Avoidance, Distress and Interference) scores were reliable in terms of internal consistency (alpha > .80). All the subscales discriminated between adolescents with and without the disorder. They also showed a positive and significant correlation with other empirically validated measures of social anxiety. The three subscales indicated relevant sensitivity (69.16-84.14%), specificity (63.46-66.03%) and areas under the curve (.74-.81%). Binary logistic regression analyses indicated the adequate predictive utility of EDAS subscales, with the Distress subscale as the best diagnostic predictor. The data provide empirical evidence of the usefulness of EDAS as a screener for adolescent social anxiety disorder in terms of reliability, convergent and discriminant validity, diagnostic accuracy and clinical usefulness.

  1. Multiclass screening of >200 pharmaceutical and other residues in aquatic foods by ultrahigh-performance liquid chromatography-quadrupole-Orbitrap mass spectrometry.

    PubMed

    Kong, Cong; Wang, Yang; Huang, Yuanfei; Yu, Huijuan

    2018-05-11

    A quick screening method of more than 200 pharmaceutical and other residues in aquatic foods based on ultrahigh-performance liquid chromatography-quadrupole-Orbitrap mass spectrometry (UHPLC-Q/Orbitrap MS) was established. In this method, after the addition of 200 μL of 1 M EDTA-Na 2 , 2 g of each sample homogenate was extracted successively with 10 mL of acetonitrile and 10 mL of ethyl acetate. The extracts were combined, dried under nitrogen flow, and redissolved in 0.1% formic acid in acetonitrile/water (4:6, v/v) for analysis. The prepared samples were analyzed by UHPLC- Q/Orbitrap MS system in Full MS/ddMS 2 (full-scan data-dependent MS/MS) mode. Compound identification was performed through comparison of the sample data with the database for standard chemicals, including the retention time, precursor ion, product ions, and isotope pattern for all 206 compounds. Five different aquatic food matrices (carp, shrimp, crab, eel, and mussel) spiked with the analytes at 1, 10, and 50 ng/g were evaluated to assess recoveries, precision, matrix effects, stability, and detection limits using the method. UHPLC analyses required 25 min, and 178-200 analytes met identification criteria at 50 ng/g depending on the matrix. Furthermore, practical application of this method for real samples displayed strong screening capability. Graphical abstract A quick screening method of >200 pharmaceutical and other residues in aquatic foods based on ultrahighperformance liquid chromatography-quadrupole-Orbitrap mass spectrometer was established. Fivedifferent aquatic food matrices, including carp, shrimp, crab, eel and mussel, were studied to evaluatescreen limit at 1, 10 and 50 μg·kg-1 level. Results suggest the high reliability, high time-efficiency and goodsimplicity of the method.

  2. Intraclass correlation estimates for cancer screening outcomes: estimates and applications in the design of group-randomized cancer screening studies.

    PubMed

    Hade, Erinn M; Murray, David M; Pennell, Michael L; Rhoda, Dale; Paskett, Electra D; Champion, Victoria L; Crabtree, Benjamin F; Dietrich, Allen; Dignan, Mark B; Farmer, Melissa; Fenton, Joshua J; Flocke, Susan; Hiatt, Robert A; Hudson, Shawna V; Mitchell, Michael; Monahan, Patrick; Shariff-Marco, Salma; Slone, Stacey L; Stange, Kurt; Stewart, Susan L; Strickland, Pamela A Ohman

    2010-01-01

    Screening has become one of our best tools for early detection and prevention of cancer. The group-randomized trial is the most rigorous experimental design for evaluating multilevel interventions. However, identifying the proper sample size for a group-randomized trial requires reliable estimates of intraclass correlation (ICC) for screening outcomes, which are not available to researchers. We present crude and adjusted ICC estimates for cancer screening outcomes for various levels of aggregation (physician, clinic, and county) and provide an example of how these ICC estimates may be used in the design of a future trial. Investigators working in the area of cancer screening were contacted and asked to provide crude and adjusted ICC estimates using the analysis of variance method estimator. Of the 29 investigators identified, estimates were obtained from 10 investigators who had relevant data. ICC estimates were calculated from 13 different studies, with more than half of the studies collecting information on colorectal screening. In the majority of cases, ICC estimates could be adjusted for age, education, and other demographic characteristics, leading to a reduction in the ICC. ICC estimates varied considerably by cancer site and level of aggregation of the groups. Previously, only two articles had published ICCs for cancer screening outcomes. We have complied more than 130 crude and adjusted ICC estimates covering breast, cervical, colon, and prostate screening and have detailed them by level of aggregation, screening measure, and study characteristics. We have also demonstrated their use in planning a future trial and the need for the evaluation of the proposed interval estimator for binary outcomes under conditions typically seen in GRTs.

  3. Reliability and screening ability of the StarT Back screening tool in patients with low back pain in physiotherapy practice, a cohort study.

    PubMed

    Robinson, Hilde Stendal; Dagfinrud, Hanne

    2017-05-31

    Low back pain (LBP) is the most common reported musculoskeletal disorder, with large prevalence numbers and high costs. Focus on early identification of patients at risk of developing chronic LBP has increased. The Keele Start Back Tool (SBT) is a questionnaire aiming at screening prognostic indicators in LBP patients, categorizing patients into risk-groups and guide treatment. The aim of this study was to explore the Norwegian version of the SBT with regard to reliability of the SBT-scoring and the screening ability in LBP patients in primary care physiotherapy. LBP patients answered a package of questionnaires twice, with 1-3 days in between, containing SBT, Hannover functional ability questionnaire, pain intensity questions and demographics. The relative and absolute reliability of SBT was calculated using intraclass correlation coefficient (ICC) and the smallest detectable change respectively. Independent sample t-tests were used for group comparisons. Fifty-two patients with LBP. Mean age (SD) was 45 (12) years and 62% were female. The ICC (95% CI) for SBT total score and psychosocial subscore was 0.89 (0.82, 0.94) and 0.82 (0.70, 0.90) respectively. None of the participants were allocated to the high risk group. The medium risk group reported significantly more pain last week and more activity limitations than the low risk group at both test and retest (0.001 ≤ p ≤ 0.003), whereas no significant difference between the groups was found on pain now (0.05 ≤ p ≤ 0.16). The Norwegian version of the SBT was reliable and the screening ability was good as the subgrouping of patients into risk-groups reflected the severity of their back problems. The SBT may be an applicable and useful tool in physiotherapy practice.

  4. The effects of intermittent illumination on a visual inspection task.

    PubMed

    Kennedy, A; Brysbaert, M; Murray, W S

    1998-02-01

    Two experiments are described in which eye movements were monitored as subjects performed a simple target-spotting task under conditions of intermittent illumination produced by varying the display-screen frame rate on a computer VDU. In Experiment 1, subjects executed a saccade from a fixation point to a target which appeared randomly at a fixed eccentricity of 14 character positions to the left or right. Saccade latency did not differ reliably as a function of screen refresh rate, but average saccade extent at 70 Hz and 110 Hz was reliably shorter than at 90 Hz and 100 Hz. Experiment 2 examined the same task using a range of target eccentricities (7, 14, and 28 character positions to the left and right) and across a wider range of screen refresh rates. The results confirmed the curvilinear relationship obtained in Experiment 1, with average saccade extent reliably shorter at refresh rates of 50 Hz and 125 Hz than at 75 Hz and 100 Hz. While the effect was greater for remote targets, analyses of the proportional target error failed to show a reliable interaction between target eccentricity and display refresh rate. In contrast to Experiment 1, there was a pronounced effect of refresh rate on saccade latency (corrected for time to write the screen frame), with shorter latencies at higher refresh rates. It may be concluded that pulsation at frequencies above fusion disrupts saccade control. However, the curvilinear functional relationship between screen refresh rate and saccade extent obtained in these studies differs from previously reported effects of intermittent illumination on the average size of "entry saccades" (the first saccade to enter a given word) in a task involving word identification (Kennedy & Murray, 1993a, 1996). This conflict of data may arise in part because within-word adjustments in viewing position, which are typical of normal reading, influence measures of average saccade extent.

  5. Validity and reliability of Patient Health Questionnaire-9 and Patient Health Questionnaire-2 to screen for depression among college students in China.

    PubMed

    Zhang, Ying-Li; Liang, Wei; Chen, Zuo-Ming; Zhang, Hong-Mei; Zhang, Jian-Hong; Weng, Xiao-Qin; Yang, Shi-Chang; Zhang, Lei; Shen, Li-Juan; Zhang, Ya-Lin

    2013-12-01

    This study examined the validity and reliability of the Patient Health Questionnaire-9 (PHQ-9) and Patient Health Questionnaire-2 (PHQ-2). The optimal cutoff score when screening for depression among Chinese college students was also determined. A total of 959 participants completed the PHQ-9 and the Beck Depression Inventory (BDI) questionnaire. The Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders was used to diagnose depression. Statistical tests were performed to determine the reliability, validity, and receiver operating characteristic curve of the data. The concurrent validity was tested by examining associations between PHQ-9 and BDI. The sensitivity and specificity, as well as the positive and negative predictive values, were calculated for different cutoff scores of PHQ-9 and PHQ-2. The internal consistency values of PHQ-9 and PHQ-2 were 0.854 and 0.727, respectively. The test-retest reliability values of PHQ-9 and PHQ-2 were 0.873 and 0.829, respectively. The scores of PHQ-9 (r = 0.790) and PHQ-2 (r = 0.651) were significantly associated with that of BDI. PHQ-9 had an optimal cutoff score of 11, which indicated a sensitivity of 0.89 and a specificity of 0.97, with an area under the curve of 0.977 (95% confidence interval: 0.966-0.988). The PHQ-2 demonstrated satisfactory sensitivity (0.81) and specificity (0.96) at the cutoff score of 3, and its area under the curve was 0.939. The PHQ-9 and the PHQ-2 are valid and reliable tools to screen depression in Chinese college students. For screening purposes, cutoff scores of 11 and 3 are recommended for PHQ-9 and PHQ-2, respectively. Copyright © 2013 Wiley Publishing Asia Pty Ltd.

  6. EPRI/NRC-RES fire human reliability analysis guidelines.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Stuart R.; Cooper, Susan E.; Najafi, Bijan

    2010-03-01

    During the 1990s, the Electric Power Research Institute (EPRI) developed methods for fire risk analysis to support its utility members in the preparation of responses to Generic Letter 88-20, Supplement 4, 'Individual Plant Examination - External Events' (IPEEE). This effort produced a Fire Risk Assessment methodology for operations at power that was used by the majority of U.S. nuclear power plants (NPPs) in support of the IPEEE program and several NPPs overseas. Although these methods were acceptable for accomplishing the objectives of the IPEEE, EPRI and the U.S. Nuclear Regulatory Commission (NRC) recognized that they required upgrades to support currentmore » requirements for risk-informed, performance-based (RI/PB) applications. In 2001, EPRI and the USNRC's Office of Nuclear Regulatory Research (RES) embarked on a cooperative project to improve the state-of-the-art in fire risk assessment to support a new risk-informed environment in fire protection. This project produced a consensus document, NUREG/CR-6850 (EPRI 1011989), entitled 'Fire PRA Methodology for Nuclear Power Facilities' which addressed fire risk for at power operations. NUREG/CR-6850 developed high level guidance on the process for identification and inclusion of human failure events (HFEs) into the fire PRA (FPRA), and a methodology for assigning quantitative screening values to these HFEs. It outlined the initial considerations of performance shaping factors (PSFs) and related fire effects that may need to be addressed in developing best-estimate human error probabilities (HEPs). However, NUREG/CR-6850 did not describe a methodology to develop best-estimate HEPs given the PSFs and the fire-related effects. In 2007, EPRI and RES embarked on another cooperative project to develop explicit guidance for estimating HEPs for human failure events under fire generated conditions, building upon existing human reliability analysis (HRA) methods. This document provides a methodology and guidance for conducting a fire HRA. This process includes identification and definition of post-fire human failure events, qualitative analysis, quantification, recovery, dependency, and uncertainty. This document provides three approaches to quantification: screening, scoping, and detailed HRA. Screening is based on the guidance in NUREG/CR-6850, with some additional guidance for scenarios with long time windows. Scoping is a new approach to quantification developed specifically to support the iterative nature of fire PRA quantification. Scoping is intended to provide less conservative HEPs than screening, but requires fewer resources than a detailed HRA analysis. For detailed HRA quantification, guidance has been developed on how to apply existing methods to assess post-fire fire HEPs.« less

  7. [Construction of a psychological aging scale for healthy people].

    PubMed

    Lin, Fei; Long, Yao; Zeng, Ni; Wu, Lei; Huang, Helang

    2017-04-28

    To construct a psychological aging scale, and to provide a tool and indexes for scientific evaluation on aging.
 Methods: The age-related psychological items were collected through literature screening and expert interview. The importance, feasibilityand the degree of authority for the psychological index system were graded by two rounds of Delphi method. Using analytic hierarchy process, the weight of dimensions and items were determined. The analysis for internal consistency reliability, correlation and exploratory factor was performed to evaluate the reliability and validity of the scales.
 Results: By two rounds of Delphi method, 17 experts offered the results as follows: the coefficient of expert authorities was 0.88±0.06, the coordination coefficients for the importance and feasibility in second round were 0.456 (P<0.01) and 0.666 (P<0.01), respectively. The consistency was good. The psychological aging scale for healthy people included 4 dimensions as follows: cognitive function, emotion, personality and motivation. The weight coefficients for the 4 dimensions were 0.338, 0.250, 0.166 and 0.258, respectively. The Cronbach's α coefficient for the scale was 0.822, the reliability was 0.817, the content validity index (CVI) was 0.847, and the cumulative contribution rate for the 5 factors was51.42%.
 Conclusion: The psychological aging scale is satisfied, which can provide reference for the evaluation for aging. The indicators were representative and well-recognized.

  8. Validity and Reliability of Assessing Body Composition Using a Mobile Application.

    PubMed

    Macdonald, Elizabeth Z; Vehrs, Pat R; Fellingham, Gilbert W; Eggett, Dennis; George, James D; Hager, Ronald

    2017-12-01

    The purpose of this study was to determine the validity and reliability of the LeanScreen (LS) mobile application that estimates percent body fat (%BF) using estimates of circumferences from photographs. The %BF of 148 weight-stable adults was estimated once using dual-energy x-ray absorptiometry (DXA). Each of two administrators assessed the %BF of each subject twice using the LS app and manually measured circumferences. A mixed-model ANOVA and Bland-Altman analyses were used to compare the estimates of %BF obtained from each method. Interrater and intrarater reliabilities values were determined using multiple measurements taken by each of the two administrators. The LS app and manually measured circumferences significantly underestimated (P < 0.05) the %BF determined using DXA by an average of -3.26 and -4.82 %BF, respectively. The LS app (6.99 %BF) and manually measured circumferences (6.76 %BF) had large limits of agreement. All interrater and intrarater reliability coefficients of estimates of %BF using the LS app and manually measured circumferences exceeded 0.99. The estimates of %BF from manually measured circumferences and the LS app were highly reliable. However, these field measures are not currently recommended for the assessment of body composition because of significant bias and large limits of agreements.

  9. Electrochemical sensor for multiplex screening of genetically modified DNA: identification of biotech crops by logic-based biomolecular analysis.

    PubMed

    Liao, Wei-Ching; Chuang, Min-Chieh; Ho, Ja-An Annie

    2013-12-15

    Genetically modified (GM) technique, one of the modern biomolecular engineering technologies, has been deemed as profitable strategy to fight against global starvation. Yet rapid and reliable analytical method is deficient to evaluate the quality and potential risk of such resulting GM products. We herein present a biomolecular analytical system constructed with distinct biochemical activities to expedite the computational detection of genetically modified organisms (GMOs). The computational mechanism provides an alternative to the complex procedures commonly involved in the screening of GMOs. Given that the bioanalytical system is capable of processing promoter, coding and species genes, affirmative interpretations succeed to identify specified GM event in terms of both electrochemical and optical fashions. The biomolecular computational assay exhibits detection capability of genetically modified DNA below sub-nanomolar level and is found interference-free by abundant coexistence of non-GM DNA. This bioanalytical system, furthermore, sophisticates in array fashion operating multiplex screening against variable GM events. Such a biomolecular computational assay and biosensor holds great promise for rapid, cost-effective, and high-fidelity screening of GMO. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Correspondence of the Boston Assessment of Traumatic Brain Injury-Lifetime (BAT-L) clinical interview and the VA TBI screen.

    PubMed

    Fortier, Catherine Brawn; Amick, Melissa M; Kenna, Alexandra; Milberg, William P; McGlinchey, Regina E

    2015-01-01

    Mild traumatic brain injury is the signature injury of Operation Enduring Freedom (OEF), Operation Iraqi Freedom (OIF), and Operation New Dawn (OND), yet its identification and diagnosis is controversial and fraught with challenges. In 2007, the Department of Veterans Affairs (VA) implemented a policy requiring traumatic brain injury (TBI) screening on all individuals returning from deployment in the OEF/OIF/OND theaters of operation that lead to the rapid and widespread use of the VA TBI screen. The Boston Assessment of TBI-Lifetime (BAT-L) is the first validated, postcombat semistructured clinical interview to characterize head injuries and diagnose TBIs throughout the life span, including prior to, during, and post-military service. Community-dwelling convenience sample of 179 OEF/OIF/OND veterans. BAT-L, VA TBI screen. Based on BAT-L diagnosis of military TBI, the VA TBI screen demonstrated similar sensitivity (0.85) and specificity (0.82) when administered by research staff. When BAT-L diagnosis was compared with historical clinician-administered VA TBI screen in a subset of participants, sensitivity was reduced. The specificity of the research-administered VA TBI screen was more than adequate. The sensitivity of the VA TBI screen, although relatively high, suggests that it does not oversample or "catch all" possible military TBIs. Traumatic brain injuries identified by the BAT-L, but not identified by the VA TBI screen, were predominantly noncombat military injuries. There is potential concern regarding the validity and reliability of the clinician administered VA TBI screen, as we found poor correspondence between it and the BAT-L, as well as low interrater reliability between the clinician-administered and research-administered screen.

  11. Is screening for fetal anomalies reliable in HIV-infected pregnant women? A multicentre study.

    PubMed

    Brossard, Philippe; Boulvain, Michel; Coll, Oriol; Barlow, Patricia; Aebi-Popp, Karoline; Bischof, Paul; Martinez de Tejada, Begoña

    2008-10-01

    To assess the impact of HIV infection on the reliability of the first-trimester screening for Down syndrome, using free beta-human chorionic gonadotrophin, pregnancy-associated plasma protein-A and fetal nuchal translucency, and of the second-trimester screening for neural tube defects, using alpha-fetoprotein. Multicentre study comparing the multiples of the median of markers for Down syndrome and neural tube defect screening among 214 HIV-infected pregnant women and 856 HIV-negative controls undergoing a first-trimester Down syndrome screening test, and 209 HIV-positive women and 836 HIV-negative controls with a risk evaluation for neural tube defect. The influence of treatment, chronic hepatitis and HIV disease characteristics were also evaluated. Multiples of the median medians for pregnancy-associated plasma protein-A and beta-human chorionic gonadotrophin were lower in HIV-positive women than controls (0.88 vs. 1.05 and 0.84 vs. 1.09, respectively; P < 0.005), but these differences had no impact on risk estimation; no differences were observed for the other markers. No association was found between HIV disease characteristics, antiretroviral treatment use at the time of screening or chronic hepatitis and marker levels. Screening for Down syndrome during the first trimester and for neural tube defect during the second trimester is accurate for HIV-infected women and should be offered, similar to HIV-negative women.

  12. Validation of the Spanish version of the McLean Screening Instrument for Borderline Personality Disorder.

    PubMed

    Soler, Joaquim; Domínguez-Clavé, Elisabet; García-Rizo, Clemente; Vega, Daniel; Elices, Matilde; Martín-Blanco, Ana; Feliu-Soler, Albert; Carmona, Cristina; Pascual, Juan C

    Borderline personality disorder (BPD) is a common and severe mental illness. Early detection is important and reliable screening instruments are required. To date, however, there has been no evidence of any specific BPD screening tool validated for the Spanish-speaking population. The McLean Screening Instrument for Borderline Personality Disorder (MSI-BPD) is a 10-item self-report questionnaire that can detect the presence of BPD in a reliable and quick manner. The aim of the present study is the validation of the MSI-BPD for its use in the Spanish-speaking population. Psychometric properties of the MSI-BPD Spanish version were examined in a sample of 344 participants (170 outpatients with the possible diagnosis of BPD and 174 healthy controls). Exploratory factor analysis revealed the existence of a bi-factorial structure. The scale showed a high internal consistency (KR-20=0.873) and an optimal test-retest reliability (ICC=0.87). Using logistic regression analyses and taking the DIB-R as reference, a best cut-off of 7 was determined, obtaining a good sensitivity (0.71) and specificity (0.68). The area under the curve, was 0.742 (95% CI 0.660-0.824). The discriminant analysis showed a classification ability of 72.8%. The Spanish version of the MSI-BPD has good psychometric properties as a measure for the screening of BPD. Its ease and quickness of use make it valuable to detect the presence of BPD in clinical and research settings. Copyright © 2016 SEP y SEPB. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. German Beck Scale for Suicide Ideation (BSS): psychometric properties from a representative population survey.

    PubMed

    Kliem, Sören; Lohmann, Anna; Mößle, Thomas; Brähler, Elmar

    2017-12-04

    Suicidal ideation has been identified as one of the major predictors of attempted or actual suicide. Routinely screening individuals for endorsing suicidal thoughts could save lives and protect many from severe psychological consequences following the suicide of loved ones. The aim of this study was to validate the German version of the Beck Scale for Suicide Ideation (BSS) in a sample representative for the Federal Republic of Germany. All 2450 participants completed the first part of the Scale, the BSS-Screen. A risk group of n = 112 individuals (4.6%) with active or passive suicidal ideation was identified and subsequently completed the entire BSS. Satisfactory internal reliability (α = .97 for the BSS-Screen; α = .94 for the entire BSS) and excellent model fit indices for the one-dimensional factorial structure of the BSS-Screen (CFI = .998; TLI = .995; RMSEA = .045 [95%-CI: .030-.061]) were confirmed. Measurement invariance analyses supported strict invariance across gender, age, and depression status. We found correlations with related self-report measures in expected directions comparable to previous studies, indicating satisfactory construct validity. Our study involved cross sectional data, hence neither predictive validity nor retest-reliability were examined. As only the risk group of n = 112 individuals completed the entire measure, confirmatory factor analyses could not be conducted for the full BSS. The German translation of the BSS is a reliable and valid instrument for assessing suicidal ideation in the general population. Using it as a screening device in general and specialized medical care could substantially advance suicide prevention.

  14. Colorectal cancer screening patient education materials-how effective is online health information?

    PubMed

    John, Elizabeth Sheena; John, Ann M; Hansberry, David R; Thomas, Prashant J; Agarwal, Prateek; Deitch, Christopher; Chokhavatia, Sita

    2016-12-01

    Patients screened for colorectal cancer (CRC) frequently turn to the Internet to improve their understanding of tests used for detection, including colonoscopy, flexible sigmoidoscopy, fecal occult blood test (FOBT), and CT colonography. It was of interest to determine the quality and readability levels of online health information. The screening tools were googled, and the top 20 results of each test were analyzed for readability, accessibility, usability, and reliability. The 80 articles excluded scientific literature and blogs. We used ten validated readability scales to measure grade levels, and one-way ANOVA and Tukey's honestly statistical different (HSD) post hoc analyses to determine any statistically significant differences among the four diagnostic tests. The LIDA tool assessed overall quality by measuring accessibility, usability, and reliability. The 80 articles were written at an 11.7 grade level, with CT colonography articles written at significantly higher levels than FOBT articles, F(3, 75) = 3.07, p = 0.033. LIDA showed moderate percentages in accessibility (83.9 %), usability (73.0 %), and reliability (75.9 %). Online health information about CRC screening tools are written at higher levels than the National Institute of Health (NIH) and American Medical Association (AMA) recommended third to seventh grade levels. More patients could benefit from this modality of information if it were written at a level and quality that would better facilitate understanding.

  15. Test-retest reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression--a systematic review and meta-analysis.

    PubMed

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2015-11-01

    Schizoaffective disorder is a frequent diagnosis, and its reliability is subject to ongoing discussion. We compared the diagnostic reliability of schizoaffective disorder with its main differential diagnoses. We systematically searched Medline, Embase, and PsycInfo for all studies on the test-retest reliability of the diagnosis of schizoaffective disorder as compared with schizophrenia, bipolar disorder, and unipolar depression. We used meta-analytic methods to describe and compare Cohen's kappa as well as positive and negative agreement. In addition, multiple pre-specified and post hoc subgroup and sensitivity analyses were carried out. Out of 4,415 studies screened, 49 studies were included. Test-retest reliability of schizoaffective disorder was consistently lower than that of schizophrenia (in 39 out of 42 studies), bipolar disorder (27/33), and unipolar depression (29/35). The mean difference in kappa between schizoaffective disorder and the other diagnoses was approximately 0.2, and mean Cohen's kappa for schizoaffective disorder was 0.50 (95% confidence interval: 0.40-0.59). While findings were unequivocal and homogeneous for schizoaffective disorder's diagnostic reliability relative to its three main differential diagnoses (dichotomous: smaller versus larger), heterogeneity was substantial for continuous measures, even after subgroup and sensitivity analyses. In clinical practice and research, schizoaffective disorder's comparatively low diagnostic reliability should lead to increased efforts to correctly diagnose the disorder. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. HIV and the epidemiologist.

    PubMed

    Gillett, G

    1989-11-18

    The need for reliable epidemiological data on HIV seropositivity rates in a general population appears to conflict with the ethical requirement that consent be obtained from persons whose blood is screened for HIV antibodies. Gillet contends that informed consent is not necessary for epidemiological screening since there is no reason to link blood samples and test results with identifiable individuals. He argues that it is ethical to test blood drawn from hospital patients who have given a very general and "non-informative sort of consent" that their blood can be used anonymously for research. Even this degree of consent may be unnecessary since it would be impossible to trace an HIV positive anonymous blood sample to its source. Gillet also argues that this method of obtaining samples relieves epidemiologists of the obligation to notify individuals whose blood tests positive for HIV.

  17. Content validation of the infant malnutrition and feeding checklist for congenital heart disease: a tool to identify risk of malnutrition and feeding difficulties in infants with congenital heart disease.

    PubMed

    St Pierre, Astrid; Khattra, Parveen; Johnson, Mandy; Cender, Laurie; Manzano, Sandra; Holsti, Liisa

    2010-10-01

    Infants with congenital heart disease (CHD) have a high prevalence of feeding difficulties and malnutrition. Early intervention decreases morbidity and long-term developmental deficits. The purpose of this study was to develop and establish the content validity of a screening checklist to identify infants with CHD at risk of feeding difficulties or inadequate nutritional intake for timely referral to a feeding specialist or dietitian. The Delphi method was used, and expert participants reached consensus on 24 risk indicators. This study is the first step in establishing the validity and reliability of a screening tool for early intervention of feeding difficulties and inadequate nutritional intake in infants with CHD. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. The use of by-products from metallurgical and mineral industries as filler in cement-based materials.

    PubMed

    Moosberg, Helena; Lagerblad, Björn; Forssberg, Eric

    2003-02-01

    This investigation has been made in order to make it possible to increase the use of by-products in cement-based materials. Use of by-products requires a screening procedure that will reliably determine their impact on concrete. A test procedure was developed. The most important properties were considered to be strength development, shrinkage, expansion and workability. The methods used were calorimetry, flow table tests, F-shape measurements, measurements of compressive and flexural strength and shrinkage/expansion measurements. Scanning electron microscopy was used to verify some results. Twelve by-products were collected from Swedish metallurgical and mineral industries and classified according to the test procedure. The investigation showed that the test procedure clearly screened out the materials that can be used in the production of concrete from the unsuitable ones.

  19. Use of clinical movement screening tests to predict injury in sport

    PubMed Central

    Chimera, Nicole J; Warren, Meghan

    2016-01-01

    Clinical movement screening tests are gaining popularity as a means to determine injury risk and to implement training programs to prevent sport injury. While these screens are being used readily in the clinical field, it is only recently that some of these have started to gain attention from a research perspective. This limits applicability and poses questions to the validity, and in some cases the reliability, of the clinical movement tests as they relate to injury prediction, intervention, and prevention. This editorial will review the following clinical movement screening tests: Functional Movement Screen™, Star Excursion Balance Test, Y Balance Test, Drop Jump Screening Test, Landing Error Scoring System, and the Tuck Jump Analysis in regards to test administration, reliability, validity, factors that affect test performance, intervention programs, and usefulness for injury prediction. It is important to review the aforementioned factors for each of these clinical screening tests as this may help clinicians interpret the current body of literature. While each of these screening tests were developed by clinicians based on what appears to be clinical practice, this paper brings to light that this is a need for collaboration between clinicians and researchers to ensure validity of clinically meaningful tests so that they are used appropriately in future clinical practice. Further, this editorial may help to identify where the research is lacking and, thus, drive future research questions in regards to applicability and appropriateness of clinical movement screening tools. PMID:27114928

  20. Validity and Reliability of the Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) in University Students.

    PubMed

    Tiburcio Sainz, Marcela; Rosete-Mohedano, Ma Guadalupe; Natera Rey, Guillermina; Martínez Vélez, Nora Angélica; Carreño García, Silvia; Pérez Cisneros, Daniel

    2016-03-02

    The Alcohol, Smoking and Substance Involvement Screening Test (ASSIST), developed by the World Health Organization (WHO), has been used successfully in many countries, but there are few studies of its validity and reliability for the Mexican population. The objective of this study was to determine the psychometric properties of the self-administered ASSIST test in university students in Mexico. This was an ex post facto non-experimental study with 1,176 undergraduate students, the majority women (70.1%) aged 18-23 years (89.5%) and single (87.5%). To estimate concurrent validity, factor analysis and tests of reliability and correlation were carried out between the subscale for alcohol and AUDIT, those for tobacco and the Fagerström Test, and those for marijuana and DAST-20. Adequate reliability coefficients were obtained for ASSIST subscales for tobacco (alpha = 0.83), alcohol (alpha = 0.76), and marijuana (alpha = 0.73). Significant correlations were found only with the AUDIT (r = 0.71) and the alcohol subscale. The best balance of sensitivity and specificity of the alcohol subscale (83.8% and 80%, respectively) and the largest area under the ROC curve (81.9%) was found with a cutoff score of 8. The self-administered version of ASSIST is a valid screening instrument to identify at-risk cases due to substance use in this population.

  1. Validation of the Middlesex Elderly Assessment of Mental State (MEAMS) as a cognitive screening test in patients with acquired brain injury in Turkey.

    PubMed

    Kutlay, Sehim; Kuçukdeveci, Ayse A; Elhan, Atilla H; Yavuzer, Gunes; Tennant, Alan

    2007-02-28

    Assessment of cognitive impairment with a valid cognitive screening tool is essential in neurorehabilitation. The aim of this study was to test the reliability and validity of the Turkish-adapted version of the Middlesex Elderly Assessment of Mental State (MEAMS) among acquired brain injury patients in Turkey. Some 155 patients with acquired brain injury admitted for rehabilitation were assessed by the adapted version of MEAMS at admission and discharge. Reliability was tested by internal consistency, intra-class correlation coefficient (ICC) and person separation index; internal construct validity by Rasch analysis; external construct validity by associations with physical and cognitive disability (FIM); and responsiveness by Effect Size. Reliability was found to be good with Cronbach's alpha of 0.82 at both admission and discharge; and likewise an ICC of 0.80. Person separation index was 0.813. Internal construct validity was good by fit of the data to the Rasch model (mean item fit -0.178; SD 1.019). Items were substantially free of differential item functioning. External construct validity was confirmed by expected associations with physical and cognitive disability. Effect size was 0.42 compared with 0.22 for cognitive FIM. The reliability and validity of the Turkish version of MEAMS as a cognitive impairment screening tool in acquired brain injury has been demonstrated.

  2. Cross-cultural adaptation and measurement properties of the Brazilian Version of the Michigan Neuropathy Screening Instrument.

    PubMed

    Sartor, Cristina D; Oliveira, Mariana D; Campos, Victoria; Ferreira, Jane S S P; Sacco, Isabel C N

    The Michigan Neuropathy Screening Instrument is an easy-to-use questionnaire aimed at screening and detecting diabetic polyneuropathy. To translate and cross-culturally adapt the MNSI to Brazilian Portuguese and evaluate its measurement properties. Two bilingual translators translated from English into Brazilian Portuguese and made a synthetic version. The synthetic version was back translated into English. A committee of specialists and the translator checked the cultural adaptations and developed a pre-final questionnaire in Brazilian Portuguese (prefinal version). In pretesting, the prefinal version was applied to a sample of 34 subjects in which each subject was interviewed to determine whether they understood each item. For the later assessment of measurement properties, 84 subjects were assessed. A final Brazilian Portuguese version of the instrument was produced after obtaining 80% agreement (SEM<0.01%) among diabetic patients and specialists. We obtained excellent intra-rater reliability (ICC 3,1 =0.90), inter-rater reliability (ICC 2,1 =0.90) and within-subject reliability ICC 3,1 =0.80, excellent internal consistency (Cronbach's alpha>0.92), reasonable construct validity for the association between the MNSI and Neuropathy Symptom Score (r=0.46, p<0.05) and excellent association between the MNSI and Neuropathy Disability Score (r=0.79, p<0.05). We did not detect floor and ceiling effects (<9.5% of patients with maximum scores). The Brazilian Portuguese version of the MNSI is suitable for application in the Brazilian diabetic population and is a reliable tool for the screening and detection of DPN. The MNSI can be used both in clinical practice and also for research purposes. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. Validity and reliability of clinical prediction rules used to screen for cervical spine injury in alert low-risk patients with blunt trauma to the neck: part 2. A systematic review from the Cervical Assessment and Diagnosis Research Evaluation (CADRE) Collaboration.

    PubMed

    Moser, N; Lemeunier, N; Southerst, D; Shearer, H; Murnaghan, K; Sutton, D; Côté, P

    2018-06-01

    To update findings of the 2000-2010 Bone and Joint Decade Task Force on Neck Pain and its Associated Disorders (Neck Pain Task Force) on the validity and reliability of clinical prediction rules used to screen for cervical spine injury in alert low-risk adult patients with blunt trauma to the neck. We searched four databases from 2005 to 2015. Pairs of independent reviewers critically appraised eligible studies using the modified QUADAS-2 and QAREL criteria. We synthesized low risk of bias studies following best evidence synthesis principles. We screened 679 citations; five had a low risk of bias and were included in our synthesis. The sensitivity of the Canadian C-spine rule ranged from 0.90 to 1.00 with negative predictive values ranging from 99 to 100%. Inter-rater reliability of the Canadian C-spine rule varied from k = 0.60 between nurses and physicians to k = 0.93 among paramedics. The inter-rater reliability of the Nexus Low-Risk Criteria was k = 0.53 between resident physicians and faculty physicians. Our review adds new evidence to the Neck Pain Task Force and supports the use of clinical prediction rules in emergency care settings to screen for cervical spine injury in alert low-risk adult patients with blunt trauma to the neck. The Canadian C-spine rule consistently demonstrated excellent sensitivity and negative predictive values. Our review, however, suggests that the reproducibility of the clinical predictions rules varies depending on the examiners level of training and experience.

  4. A simple microplate-based method for the determination of α-amylase activity using the glucose assay kit (GOD method).

    PubMed

    Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini

    2016-11-15

    For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Validity and reliability of the Turkish version of the DSM-5 Generalized Anxiety Disorder Severity Scale for children aged 11–17 years

    PubMed

    Yalın Sapmaz, Şermin; Özek Erkuran, Handan; Ergin, Dilek; Öztürk, Masum; Şen Celasin, Nesrin; Karaarslan, Duygu; Aydemir, Ömer

    2018-02-23

    Background/aim: This study aimed to assess the validity and reliability of the Turkish version of the DSM-5 Generalized Anxiety Disorder Severity Scale - Child Form. Materials and methods: The study sample consisted of 32 patients treated in a child psychiatry unit and diagnosed with generalized anxiety disorder and 98 healthy volunteers who were attending middle or high school during the study period. For the assessment, the Screen for Child Anxiety and Related Emotional Disorders (SCARED) was also used along with the DSM-5 Generalized Anxiety Disorder Severity Scale - Child Form. Results: Regarding reliability analyses, the Cronbach alpha internal consistency coefficient was calculated as 0.932. The test-retest correlation coefficient was calculated as r = 0.707. As for construct validity, one factor that could explain 62.6% of the variance was obtained and this was consistent with the original construct of the scale. As for concurrent validity, the scale showed a high correlation with SCARED. Conclusion: It was concluded that Turkish version of the DSM-5 Generalized Anxiety Disorder Severity Scale - Child Form could be utilized as a valid and reliable tool both in clinical practice and for research purposes.

  6. mRAISE: an alternative algorithmic approach to ligand-based virtual screening

    NASA Astrophysics Data System (ADS)

    von Behren, Mathias M.; Bietz, Stefan; Nittinger, Eva; Rarey, Matthias

    2016-08-01

    Ligand-based virtual screening is a well established method to find new lead molecules in todays drug discovery process. In order to be applicable in day to day practice, such methods have to face multiple challenges. The most important part is the reliability of the results, which can be shown and compared in retrospective studies. Furthermore, in the case of 3D methods, they need to provide biologically relevant molecular alignments of the ligands, that can be further investigated by a medicinal chemist. Last but not least, they have to be able to screen large databases in reasonable time. Many algorithms for ligand-based virtual screening have been proposed in the past, most of them based on pairwise comparisons. Here, a new method is introduced called mRAISE. Based on structural alignments, it uses a descriptor-based bitmap search engine (RAISE) to achieve efficiency. Alignments created on the fly by the search engine get evaluated with an independent shape-based scoring function also used for ranking of compounds. The correct ranking as well as the alignment quality of the method are evaluated and compared to other state of the art methods. On the commonly used Directory of Useful Decoys dataset mRAISE achieves an average area under the ROC curve of 0.76, an average enrichment factor at 1 % of 20.2 and an average hit rate at 1 % of 55.5. With these results, mRAISE is always among the top performing methods with available data for comparison. To access the quality of the alignments calculated by ligand-based virtual screening methods, we introduce a new dataset containing 180 prealigned ligands for 11 diverse targets. Within the top ten ranked conformations, the alignment closest to X-ray structure calculated with mRAISE has a root-mean-square deviation of less than 2.0 Å for 80.8 % of alignment pairs and achieves a median of less than 2.0 Å for eight of the 11 cases. The dataset used to rate the quality of the calculated alignments is freely available at http://www.zbh.uni-hamburg.de/mraise-dataset.html. The table of all PDB codes contained in the ensembles can be found in the supplementary material. The software tool mRAISE is freely available for evaluation purposes and academic use (see http://www.zbh.uni-hamburg.de/raise).

  7. Fourier transform infrared spectroscopy for the prediction of fatty acid profiles in Mucor fungi grown in media with different carbon sources.

    PubMed

    Shapaval, Volha; Afseth, Nils Kristian; Vogt, Gjermund; Kohler, Achim

    2014-09-11

    Fungal production of polyunsaturated fatty acids (PUFAs) is a highly potential approach in biotechnology. Currently the main focus is directed towards screening of hundreds strains in order to select of few potential ones. Thus, a reliable method for screening a high number of strains within a short period of time is needed. Here, we present a novel method for screening of PUFA-producing fungi by high-throughput microcultivation and FTIR spectroscopy. In the study selected Mucor fungi were grown in media with different carbon sources and fatty acid profiles were predicted on the basis of the obtained spectral data. FTIR spectra were calibrated against fatty acid analysis by GC-FD. The calibration models were cross-validated and correlation coefficients (R2) from 0.71 to 0.78 with RMSECV (root mean squared error) from 2.86% to 6.96% (percentage of total fat) were obtained. The FTIR results show a strong correlation to the results obtained by GC analysis, where high total contents of unsaturated fatty acids (both PUFA and MUFA) were achieved for Mucor plumbeus VI02019 cultivated in canola, olive and sunflower oil and Mucor hiemalis VI01993 cultivated in canola and olive oil.

  8. Clinically Practical Approach for Screening of Low Muscularity Using Electronic Linear Measures on Computed Tomography Images in Critically Ill Patients.

    PubMed

    Avrutin, Egor; Moisey, Lesley L; Zhang, Roselyn; Khattab, Jenna; Todd, Emma; Premji, Tahira; Kozar, Rosemary; Heyland, Daren K; Mourtzakis, Marina

    2017-12-06

    Computed tomography (CT) scans performed during routine hospital care offer the opportunity to quantify skeletal muscle and predict mortality and morbidity in intensive care unit (ICU) patients. Existing methods of muscle cross-sectional area (CSA) quantification require specialized software, training, and time commitment that may not be feasible in a clinical setting. In this article, we explore a new screening method to identify patients with low muscle mass. We analyzed 145 scans of elderly ICU patients (≥65 years old) using a combination of measures obtained with a digital ruler, commonly found on hospital radiological software. The psoas and paraspinal muscle groups at the level of the third lumbar vertebra (L3) were evaluated by using 2 linear measures each and compared with an established method of CT image analysis of total muscle CSA in the L3 region. There was a strong association between linear measures of psoas and paraspinal muscle groups and total L3 muscle CSA (R 2 = 0.745, P < 0.001). Linear measures, age, and sex were included as covariates in a multiple logistic regression to predict those with low muscle mass; receiver operating characteristic (ROC) area under the curve (AUC) of the combined psoas and paraspinal linear index model was 0.920. Intraclass correlation coefficients (ICCs) were used to evaluate intrarater and interrater reliability, resulting in scores of 0.979 (95% CI: 0.940-0.992) and 0.937 (95% CI: 0.828-0.978), respectively. A digital ruler can reliably predict L3 muscle CSA, and these linear measures may be used to identify critically ill patients with low muscularity who are at risk for worse clinical outcomes. © 2017 American Society for Parenteral and Enteral Nutrition.

  9. Development and Validation of a Safety Climate Scale for Manufacturing Industry

    PubMed Central

    Ghahramani, Abolfazl; Khalkhali, Hamid R.

    2015-01-01

    Background This paper describes the development of a scale for measuring safety climate. Methods This study was conducted in six manufacturing companies in Iran. The scale developed through conducting a literature review about the safety climate and constructing a question pool. The number of items was reduced to 71 after performing a screening process. Results The result of content validity analysis showed that 59 items had excellent item content validity index (≥ 0.78) and content validity ratio (> 0.38). The exploratory factor analysis resulted in eight safety climate dimensions. The reliability value for the final 45-item scale was 0.96. The result of confirmatory factor analysis showed that the safety climate model is satisfactory. Conclusion This study produced a valid and reliable scale for measuring safety climate in manufacturing companies. PMID:26106508

  10. Advancement of High Power Quasi-CW Laser Diode Arrays For Space-based Laser Instruments

    NASA Technical Reports Server (NTRS)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, nathaniel R.; Baggott, Renee S.; Singh, Upendra N.; Kavaya, Michael J.

    2004-01-01

    Space-based laser and lidar instruments play an important role in NASA s plans for meeting its objectives in both Earth Science and Space Exploration areas. Almost all the lidar instrument concepts being considered by NASA scientist utilize moderate to high power diode-pumped solid state lasers as their transmitter source. Perhaps the most critical component of any solid state laser system is its pump laser diode array which essentially dictates instrument efficiency, reliability and lifetime. For this reason, premature failures and rapid degradation of high power laser diode arrays that have been experienced by laser system designers are of major concern to NASA. This work addresses these reliability and lifetime issues by attempting to eliminate the causes of failures and developing methods for screening laser diode arrays and qualifying them for operation in space.

  11. Potential of cross-priming amplification and DNA-based lateral-flow strip biosensor for rapid on-site GMO screening.

    PubMed

    Huang, Xin; Zhai, Congcong; You, Qimin; Chen, Hongjun

    2014-07-01

    The requirement to monitor the presence of genetically modified organisms (GMO) in a variety of marked products has generated an increasing demand for reliable, rapid, and time and cost-effective analytical methods. Here we report an on-site method for rapid detection of cauliflower mosaic virus promoter (CaMV 35S), a common element present in most GMO, using cross-priming amplification (CPA) technology. Detection was achieved using a DNA-based contamination-proof strip biosensor. The limit of detection was 30 copies for the pBI121 plasmid containing the CaMV 35S gene. The certified reference sample of GM maize line MON810 was detectable even at the low relative mass concentration of 0.05%. The developed CPA method had high specificity for the CaMV 35S gene, as compared with other GM lines not containing this gene and non-GM products. The method was further validated using nine real-world samples, and the results were confirmed by real-time PCR analysis. Because of its simplicity, rapidity, and high sensitivity, this method of detecting the CaMV 35S gene has great commercial prospects for rapid GMO screening of high-consumption food and agriculture products.

  12. Automatic Spiral Analysis for Objective Assessment of Motor Symptoms in Parkinson's Disease.

    PubMed

    Memedi, Mevludin; Sadikov, Aleksander; Groznik, Vida; Žabkar, Jure; Možina, Martin; Bergquist, Filip; Johansson, Anders; Haubenberger, Dietrich; Nyholm, Dag

    2015-09-17

    A challenge for the clinical management of advanced Parkinson's disease (PD) patients is the emergence of fluctuations in motor performance, which represents a significant source of disability during activities of daily living of the patients. There is a lack of objective measurement of treatment effects for in-clinic and at-home use that can provide an overview of the treatment response. The objective of this paper was to develop a method for objective quantification of advanced PD motor symptoms related to off episodes and peak dose dyskinesia, using spiral data gathered by a touch screen telemetry device. More specifically, the aim was to objectively characterize motor symptoms (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Digitized upper limb movement data of 65 advanced PD patients and 10 healthy (HE) subjects were recorded as they performed spiral drawing tasks on a touch screen device in their home environment settings. Several spatiotemporal features were extracted from the time series and used as inputs to machine learning methods. The methods were validated against ratings on animated spirals scored by four movement disorder specialists who visually assessed a set of kinematic features and the motor symptom. The ability of the method to discriminate between PD patients and HE subjects and the test-retest reliability of the computed scores were also evaluated. Computed scores correlated well with mean visual ratings of individual kinematic features. The best performing classifier (Multilayer Perceptron) classified the motor symptom (bradykinesia or dyskinesia) with an accuracy of 84% and area under the receiver operating characteristics curve of 0.86 in relation to visual classifications of the raters. In addition, the method provided high discriminating power when distinguishing between PD patients and HE subjects as well as had good test-retest reliability. This study demonstrated the potential of using digital spiral analysis for objective quantification of PD-specific and/or treatment-induced motor symptoms.

  13. The value of ultrasonography alone in screening surveys of cystic echinococcosis in children in Turkey.

    PubMed

    Kilimcioğlu, Ali A; Ozkol, Mine; Bayindir, Petek; Girginkardeşler, Nogay; Ostan, Ipek; Ok, Ulgen Z

    2006-12-01

    A total of 1,205 primary school children were examined for cystic echinococcosis in five villages of Manisa, Turkey, to evaluate the efficacy of diagnostic methods of this infection in community-based screening surveys. Six hundred and thirty children from three villages, examined by a portable ultrasound scanner, chest microfilm and serological methods (ELISA, indirect hemagglutination) in our previous study, were designated as Study Group 1; and 575 children, from two adjacent villages, examined by ultrasonography alone in the present study, were designated as Study Group 2. In Study Group 1, hepatic cystic echinococcosis was detected in two cases (0.3%) by ultrasonography, while 43 (8.9%) and 49 (10.1%) cases were found to be positive for cystic echinococcosis by ELISA and indirect hemagglutination, respectively. Three of 575 children (0.5%) were diagnosed with cystic echinococcosis (two hepatic and one renal involvement) by ultrasonography alone in Study Group 2; and lung lesions were later detected in both cases with liver involvement by chest radiography. Our results suggested that serological tests may be beneficial in suspected cases for confirmation and differential diagnosis, but have some drawbacks, such as discrepancy in results and high false seropositivity rates. Chest microfilm is not easy in field studies and exposure to X-ray is undesirable. As a reliable, simple, inexpensive and rapid technique, ultrasonography alone is recommended to be used in community-based screening surveys for cystic echinococcosis with confirmatory tests for suspected cases found during the screening program.

  14. Trainable structure-activity relationship model for virtual screening of CYP3A4 inhibition.

    PubMed

    Didziapetris, Remigijus; Dapkunas, Justas; Sazonovas, Andrius; Japertas, Pranas

    2010-11-01

    A new structure-activity relationship model predicting the probability for a compound to inhibit human cytochrome P450 3A4 has been developed using data for >800 compounds from various literature sources and tested on PubChem screening data. Novel GALAS (Global, Adjusted Locally According to Similarity) modeling methodology has been used, which is a combination of baseline global QSAR model and local similarity based corrections. GALAS modeling method allows forecasting the reliability of prediction thus defining the model applicability domain. For compounds within this domain the statistical results of the final model approach the data consistency between experimental data from literature and PubChem datasets with the overall accuracy of 89%. However, the original model is applicable only for less than a half of PubChem database. Since the similarity correction procedure of GALAS modeling method allows straightforward model training, the possibility to expand the applicability domain has been investigated. Experimental data from PubChem dataset served as an example of in-house high-throughput screening data. The model successfully adapted itself to both data classified using the same and different IC₅₀ threshold compared with the training set. In addition, adjustment of the CYP3A4 inhibition model to compounds with a novel chemical scaffold has been demonstrated. The reported GALAS model is proposed as a useful tool for virtual screening of compounds for possible drug-drug interactions even prior to the actual synthesis.

  15. Clinical utility of a single-item test for DSM-5 alcohol use disorder among outpatients with anxiety and depressive disorders.

    PubMed

    Bartoli, Francesco; Crocamo, Cristina; Biagi, Enrico; Di Carlo, Francesco; Parma, Francesca; Madeddu, Fabio; Capuzzi, Enrico; Colmegna, Fabrizia; Clerici, Massimo; Carrà, Giuseppe

    2016-08-01

    There is a lack of studies testing accuracy of fast screening methods for alcohol use disorder in mental health settings. We aimed at estimating clinical utility of a standard single-item test for case finding and screening of DSM-5 alcohol use disorder among individuals suffering from anxiety and mood disorders. We recruited adults consecutively referred, in a 12-month period, to an outpatient clinic for anxiety and depressive disorders. We assessed the National Institute on Alcohol Abuse and Alcoholism (NIAAA) single-item test, using the Mini- International Neuropsychiatric Interview (MINI), plus an additional item of Composite International Diagnostic Interview (CIDI) for craving, as reference standard to diagnose a current DSM-5 alcohol use disorder. We estimated sensitivity and specificity of the single-item test, as well as positive and negative Clinical Utility Indexes (CUIs). 242 subjects with anxiety and mood disorders were included. The NIAAA single-item test showed high sensitivity (91.9%) and specificity (91.2%) for DSM-5 alcohol use disorder. The positive CUI was 0.601, whereas the negative one was 0.898, with excellent values also accounting for main individual characteristics (age, gender, diagnosis, psychological distress levels, smoking status). Testing for relevant indexes, we found an excellent clinical utility of the NIAAA single-item test for screening true negative cases. Our findings support a routine use of reliable methods for rapid screening in similar mental health settings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Gonorrhea in the Unsuspected Woman

    ERIC Educational Resources Information Center

    Feiman, Daniel T.

    1974-01-01

    This study attempts to improve the control of venereal disease by screening 1,000 asymptomatic women for gonorrhea on the campus of California State University, Los Angeles. The purpose of the screening was to develop reliable statistics, to treat all cases vigorously, and to control the spread of venereal disease. (PD)

  17. Filling the gap between lab and clinical impact: An open randomized diagnostic trial comparing urinary ethylglucuronide and ethanol in alcohol dependent outpatients.

    PubMed

    Barrio, Pablo; Teixidor, Lídia; Ortega, Lluisa; Lligoña, Anna; Rico, Nayra; Bedini, José Luis; Vieta, Eduard; Gual, Antoni

    2018-02-01

    Efforts aimed at reducing alcohol-related harm include early detection of risky drinkers as well as detection of early relapse in patients with alcohol dependence. Ethyl glucuronide (EtG) has been proven to be a reliable biomarker for the detection of recent drinking; however, no randomized, diagnostic trial to date has tested its impact on drinking outcomes. The aim of this study was to assess, in a randomized design, the implications of EtG screening on alcohol outcomes, compared to screening with a low sensitivity biomarker such as ethanol. Alcohol dependent outpatients were randomized to either 24 weeks of continuous screening with EtG or ethanol. Patients were aware of screening methods and results. After 24 weeks, all participants were screened with EtG. Self-reports were also gathered. A logistic regression compared the rate of EtG positive results at study end between groups. Generalized estimating equations evaluated the descending monthly rate of EtG positive patients in the EtG group. A total of 162 patients were randomized. During the study period, the ethanol group showed less patients with positive screens (19/64 (29.7%) vs 58/98 (59%)). After 24 weeks, the EtG group showed a greater number of patients having a negative screening test compared to ethanol subjects when they were all screened with EtG (5/62 (8.1%) vs 13/39 (33.3%)). A significant decrease in the rate of EtG positive patients was found for the first three months of the study. Routine screening with EtG seems to reduce drinking and improve abstinence rates in alcohol dependent outpatients. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Neonatal screening for glutaric aciduria type I: strategies to proceed.

    PubMed

    Lindner, M; Ho, S; Fang-Hoffmann, J; Hoffmann, G F; Kölker, S

    2006-01-01

    Acute encephalopathic crisis in glutaric aciduria type I results in an unfavourable disease course and poor outcome, dominated by dystonia, feeding problems, seizures and reduced life expectancy. A conditio sine qua non for the prevention of irreversible brain damage is timely diagnosis and start of therapy, i.e. before the onset of neurological disease. As there are no specific clinical signs or symptoms that allow a reliable detection of these patients before the manifestation of encephalopathic crises, neonatal screening programmes for glutaric aciduria type I have been established in some countries using analysis of glutarylcarnitine in dried blood spots by tandem mass spectrometry. This article summarizes recent strategies, pitfalls and shortcomings of mass screening for glutaric aciduria type I, focusing on the relevant risk of missing patients with a mild biochemical phenotype (i.e. low excretors). Furthermore, it evaluates a binary strategy--using glutarylcarnitine as primary variable and glutarylcarnitine/acylcarnitine ratios as secondary variable--to improve the diagnostic sensitivity and specificity of neonatal screening for glutaric aciduria type I. An optimization of diagnostic as well as therapeutic procedures must be achieved before screening for glutaric aciduria type I can be regarded as reliable and beneficial for all patients.

  19. Screening of current post-traumatic stress disorder in patients with substance use disorder using the Depression, Anxiety and Stress Scale (DASS-21): a reliable and convenient measure.

    PubMed

    Kok, Tim; de Haan, Hein A; van der Meer, Margreet; Najavits, Lisa M; De Jong, Cor A J

    2015-01-01

    Several instruments have been developed and validated as screens for post-traumatic stress disorder (PTSD) in substance use disorder (SUD) patients. Unfortunately, many of these instruments have one or several disadvantages (e.g. low specificity, low sensitivity or high costs). No research has been conducted on instruments that screen simultaneously for other psychiatric disorders, which would be a potentially time-saving and cost-effective approach. In the current study we tested the psychometric properties of the Depression, Anxiety and Stress Scale (DASS) as a screen for PTSD. The DASS was assessed in an inpatient facility during intake with 58 patients and again 4 weeks after admission. Another 138 patients were assessed 4 weeks after admission only. The results were compared to the Clinician-Administered PTSD Scale (CAPS) that was also administered after 4 weeks of abstinence. ROC curve analyses showed an area under the curve of 0.84 for the DASS at intake and 0.78 for the DASS after 4 weeks' abstinence. The DASS is therefore a reliable and convenient measure to use as a screen for PTSD in SUD patients. © 2014 S. Karger AG, Basel.

  20. A new real-time PCR protocol for detection of avian haemosporidians.

    PubMed

    Bell, Jeffrey A; Weckstein, Jason D; Fecchio, Alan; Tkach, Vasyl V

    2015-07-19

    Birds possess the most diverse assemblage of haemosporidian parasites; including three genera, Plasmodium, Haemoproteus, and Leucocytozoon. Currently there are over 200 morphologically identified avian haemosporidian species, although true species richness is unknown due to great genetic diversity and insufficient sampling in highly diverse regions. Studies aimed at surveying haemosporidian diversity involve collecting and screening samples from hundreds to thousands of individuals. Currently, screening relies on microscopy and/or single or nested standard PCR. Although effective, these methods are time and resource consuming, and in the case of microscopy require substantial expertise. Here we report a newly developed real-time PCR protocol designed to quickly and reliably detect all three genera of avian haemosporidians in a single biochemical reaction. Using available DNA sequences from avian haemosporidians we designed primers R330F and R480RL, which flank a 182 base pair fragment of mitochondrial conserved rDNA. These primers were initially tested using real-time PCR on samples from Malawi, Africa, previously screened for avian haemosporidians using traditional nested PCR. Our real time protocol was further tested on 94 samples from the Cerrado biome of Brazil, previously screened using a single PCR assay for haemosporidian parasites. These samples were also amplified using modified nested PCR protocols, allowing for comparisons between the three different screening methods (single PCR, nested PCR, real-time PCR). The real-time PCR protocol successfully identified all three genera of avian haemosporidians from both single and mixed infections previously detected from Malawi. There was no significant difference between the three different screening protocols used for the 94 samples from the Brazilian Cerrado (χ(2) = 0.3429, df = 2, P = 0.842). After proving effective, the real-time protocol was used to screen 2113 Brazilian samples, identifying 693 positive samples. Our real-time PCR assay proved as effective as two widely used molecular screening techniques, single PCR and nested PCR. However, the real-time protocol has the distinct advantage of detecting all three genera in a single reaction, which significantly increases efficiency by greatly decreasing screening time and cost. Our real-time PCR protocol is therefore a valuable tool in the quickly expanding field of avian haemosporidian research.

  1. Ion thruster design and analysis

    NASA Technical Reports Server (NTRS)

    Kami, S.; Schnelker, D. E.

    1976-01-01

    Questions concerning the mechanical design of a thruster are considered, taking into account differences in the design of an 8-cm and a 30-cm model. The components of a thruster include the thruster shell assembly, the ion extraction electrode assembly, the cathode isolator vaporizer assembly, the neutralizer isolator vaporizer assembly, ground screen and mask, and the main isolator vaporizer assembly. Attention is given to the materials used in thruster fabrication, the advanced manufacturing methods used, details of thruster performance, an evaluation of thruster life, structural and thermal design considerations, and questions of reliability and quality assurance.

  2. Genetic and QTL analysis of resistance to Xiphinema index in a grapevine cross.

    PubMed

    Xu, K; Riaz, S; Roncoroni, N C; Jin, Y; Hu, R; Zhou, R; Walker, M A

    2008-01-01

    Resistance to the dagger nematode Xiphinema index has been an important objective in grape rootstock breeding programs. This nematode not only causes severe feeding damage to the root system, but it also vectors grapevine fanleaf virus (GFLV), the causal agent of fanleaf degeneration and one of the most severe viral diseases of grape. The established screening procedures for dagger nematode resistance are time consuming and can produce inconsistent results. A fast and reliable greenhouse-based system for screening resistance to X. index that is suitable for genetic studies and capable of evaluating breeding populations is needed. In this report, the dynamics of nematode numbers, gall formation, and root weight loss were investigated using a variety of soil mixes and pot sizes over a 52-week period. Results indicated that the number of galls formed was correlated with the size of the nematode population and with the degree of root weight loss. After inoculation with 100 nematodes, gall formation could be reliably evaluated in 4-8 weeks in most plant growth conditions and results were obtained 6 months more rapidly than past evaluation methods. This modified X. index resistance screening method was successfully applied to 185 of the 188 F(1) progeny from a cross of D8909-15 x F8909-17 (the 9621 population), which segregates for a form of X. index resistance originally derived from Vitis arizonica. Quantitative trait loci (QTL) analysis was carried out on both parental genetic maps of 255 markers using MapQTL 4.0. Results revealed that X. index resistance is controlled by a major QTL, designated Xiphinema index Resistance 1 (XiR1), near marker VMC5a10 on chromosome 19. The XiR1 QTL was supported by a LOD score of 36.9 and explained 59.9% of the resistance variance in the mapping population.

  3. Colorimetry and SERS dual-mode detection of telomerase activity: combining rapid screening with high sensitivity

    NASA Astrophysics Data System (ADS)

    Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping

    2014-01-01

    As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis. Electronic supplementary information (ESI) available: TEM images of individual MB@Au NPs, results of dynamic light scattering analysis and extinction spectrum obtained using colorimetry detection. See DOI: 10.1039/c3nr04942f

  4. Development and application of a multiplex reverse-transcription polymerase chain reaction assay for screening a global collection of Citrus tristeza virus isolates.

    PubMed

    Roy, Avijit; Ananthakrishnan, G; Hartung, John S; Brlansky, R H

    2010-10-01

    The emerging diversity of Citrus tristeza virus (CTV) genotypes has complicated detection and diagnostic measures and prompted the search for new differentiation methods. To simplify the identification and differentiation of CTV genotypes, a multiplex reverse-transcription polymerase chain reaction (RT-PCR) technique for the screening of CTV isolates was developed. Variable regions within the open reading frame (ORF)-1a of diverse CTV genotypes were identified to develop first a simplex (S) and then a hexaplex (H) RT-PCR. CTV isolates have been grouped previously into five genotypes (namely, T3, T30, T36, VT, and B165) based on the nucleotide sequence comparisons and phylogenetic analyses. Nucleotide sequences from GenBank were used to design species and genotype-specific primers (GSPs). The GSPs were initially used for reliable detection of all CTV genotypes using S-RT-PCR. Furthermore, detection of all five recognized CTV genotypes was established using the H-RT-PCR. Six amplicons, one generic to all CTV isolates and one for each of the five recognized genotypes, were identified on the basis of their size and were confirmed by sequence analysis. In all, 175 CTV isolates from 29 citrus-growing countries were successfully analyzed by S- and H-RT-PCR. Of these, 97 isolates contained T36 genotypes, 95 contained T3 genotypes, 76 contained T30 genotypes, 71 contained VT genotypes, and 24 contained B165 genotype isolates. In total, 126 isolates contained mixed infections of 2 to 5 of the known CTV genotypes. Two of the CTV isolates could not be assigned to a known genotype. H-RT-PCR provides a sensitive, specific, reliable, and rapid way to screen for CTV genotypes compared with other methods for CTV genotype detection. Efficient identification of CTV genotypes will facilitate a better understanding of CTV isolates, including the possible interaction of different genotypes in causing or preventing diseases. The methods described can also be used in virus-free citrus propagation programs and in the development of CTV-resistant cultivars.

  5. A comparison of restriction fragment length polymorphism, tetra primer amplification refractory mutation system PCR and unlabeled probe melting analysis for LTA+252 C>T SNP genotyping.

    PubMed

    Soler, Stephan; Rittore, Cécile; Touitou, Isabelle; Philibert, Laurent

    2011-02-20

    From the wide range of methods currently available for genotyping, we wished to identify a quick, reliable and affordable approach for routine use in our laboratory for LTA+252 C>T SNP screening. We set up and compared three genotyping methods for SNP detection: restriction fragment length polymorphism (RFLP), tetra primer amplification refractory mutation system PCR (TPAP) and unlabeled probe melting analysis (UPMA). The SNP model used was LTA+252 C>T, a cytokine gene polymorphism that has been associated with response to treatment in rheumatoid arthritis. The study was performed using 46 samples from healthy Caucasian volunteers. Allele and genotype distribution was similar to that previously described in the same population. All three genotyping methods showed good reproducibility and are suitable for a medium scale throughput molecular platform. UPMA was the most cost effective, reliable and safe method since it required the shortest technician time, could be performed in a single closed tube and involved automatic data analysis. This work is the first to compare these three genotyping techniques and provides evidence for UPMA being the method of choice for LTA+252 C>T SNP genotyping. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9-12 Years Children.

    PubMed

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9-11 years were determined by two methods of CPBA and HPLC. Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes.

  7. Novel shortcut estimation method for regeneration energy of amine solvents in an absorption-based carbon capture process.

    PubMed

    Kim, Huiyong; Hwang, Sung June; Lee, Kwang Soon

    2015-02-03

    Among various CO2 capture processes, the aqueous amine-based absorption process is considered the most promising for near-term deployment. However, the performance evaluation of newly developed solvents still requires complex and time-consuming procedures, such as pilot plant tests or the development of a rigorous simulator. Absence of accurate and simple calculation methods for the energy performance at an early stage of process development has lengthened and increased expense of the development of economically feasible CO2 capture processes. In this paper, a novel but simple method to reliably calculate the regeneration energy in a standard amine-based carbon capture process is proposed. Careful examination of stripper behaviors and exploitation of energy balance equations around the stripper allowed for calculation of the regeneration energy using only vapor-liquid equilibrium and caloric data. Reliability of the proposed method was confirmed by comparing to rigorous simulations for two well-known solvents, monoethanolamine (MEA) and piperazine (PZ). The proposed method can predict the regeneration energy at various operating conditions with greater simplicity, greater speed, and higher accuracy than those proposed in previous studies. This enables faster and more precise screening of various solvents and faster optimization of process variables and can eventually accelerate the development of economically deployable CO2 capture processes.

  8. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols

    USDA-ARS?s Scientific Manuscript database

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes for functional deficits that reduce physical performance. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the tes...

  9. Development, Reliability, and Validity of a Child Dissociation Scale.

    ERIC Educational Resources Information Center

    Putnam, Frank W.; And Others

    1993-01-01

    Evaluation of the Child Dissociative Checklist found it to be a reliable and valid observer report measure of dissociation in children, including sexually abused girls and children with dissociative disorder and with multiple personality disorder. The checklist, which is appended, is intended as a clinical screening instrument and research measure…

  10. An integrated miRNA functional screening and target validation method for organ morphogenesis.

    PubMed

    Rebustini, Ivan T; Vlahos, Maryann; Packer, Trevor; Kukuruzinska, Maria A; Maas, Richard L

    2016-03-16

    The relative ease of identifying microRNAs and their increasing recognition as important regulators of organogenesis motivate the development of methods to efficiently assess microRNA function during organ morphogenesis. In this context, embryonic organ explants provide a reliable and reproducible system that recapitulates some of the important early morphogenetic processes during organ development. Here we present a method to target microRNA function in explanted mouse embryonic organs. Our method combines the use of peptide-based nanoparticles to transfect specific microRNA inhibitors or activators into embryonic organ explants, with a microRNA pulldown assay that allows direct identification of microRNA targets. This method provides effective assessment of microRNA function during organ morphogenesis, allows prioritization of multiple microRNAs in parallel for subsequent genetic approaches, and can be applied to a variety of embryonic organs.

  11. Underestimation of substance abuse in psychiatric patients by conventional hospital screening.

    PubMed

    Reidy, Lisa J; Junquera, Patricia; Van Dijck, Karolien; Steele, Bernard W; Nemeroff, Charles B

    2014-12-01

    Psychiatric diagnosis mainly relies on behavioral signs and symptoms. Substance abuse can mimic the clinical presentation of primary psychiatric disorders and can also complicate the management of psychiatric patients. The reliability and accuracy of urine toxicology is a vital tool in the optimal treatment of these patients. Current demographics of substance abuse suggest that in addition to the most conventional drugs of abuse (e.g. cocaine, cannabis) that are of concern to treating physicians, prescription medications and new designer drugs also should be when evaluating patients who present with symptoms of psychosis/drug addiction or altered mental status. Urine samples from 220 psychiatric inpatients admitted to either an acute drug and alcohol unit or acute psychiatric unit were analyzed for drugs by the standard hospital assay (KIMS) and by a more sensitive ELISA and GC-MS basic drug screening protocol. The standard hospital toxicology (KIMS) was inferior to the ELISA and GC-MS methods in terms of both assay sensitivity and in detecting a broader number of drugs. The KIMS tests failed to identify opiates and amphetamine/methamphetamine in 50% of the patients. The KIMS screen did not identify zolpidem, buprenorphine and a number of synthetic drugs of abuse including cathinone and tryptamines. In order to reliably identify substance abuse in patients with altered mental status in inpatient settings, analytical methodologies with adequate assay sensitivity and range to detect the vast majority of commonly abused illicit drugs and prescription medications are required for optimal clinical assessment and treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Validation of a newly developed hexaplex real-time PCR assay for screening for presence of GMOs in food, feed and seed.

    PubMed

    Bahrdt, C; Krech, A B; Wurz, A; Wulff, D

    2010-03-01

    For years, an increasing number and diversity of genetically modified plants has been grown on a commercial scale. The need for detection and identification of these genetically modified organisms (GMOs) calls for broad and at the same time flexible high throughput testing methods. Here we describe the development and validation of a hexaplex real-time polymerase chain reaction (PCR) screening assay covering more than 100 approved GMOs containing at least one of the GMO targets of the assay. The assay comprises detection systems for Cauliflower Mosaic Virus 35S promoter, Agrobacterium tumefaciens NOS terminator, Figwort Mosaic Virus 34S promoter and two construct-specific sequences present in novel genetically modified soybean and maize that lack common screening elements. Additionally a detection system for an internal positive control (IPC) indicating the presence or absence of PCR inhibiting substances was included. The six real-time PCR systems were allocated to five detection channels showing no significant crosstalk between the detection channels. As part of an extensive validation, a limit of detection (LOD(abs)) < or = ten target copies was proven in hexaplex format. A sensitivity < or = ten target copies of each GMO detection system was still shown in highly asymmetric target situations in the presence of 1,000 copies of all other GMO targets of each detection channel. Furthermore, the applicability to a broad sample spectrum and reliable indication of inhibition by the IPC system was demonstrated. The presented hexaplex assay offers sensitive and reliable detection of GMOs in processed and unprocessed food, feed and seed samples with high efficiency.

  13. Clinical utilisation of a rapid low-pass whole genome sequencing technique for the diagnosis of aneuploidy in human embryos prior to implantation

    PubMed Central

    Wells, Dagan; Kaur, Kulvinder; Grifo, Jamie; Glassner, Michael; Taylor, Jenny C; Fragouli, Elpida; Munne, Santiago

    2014-01-01

    Background The majority of human embryos created using in vitro fertilisation (IVF) techniques are aneuploid. Comprehensive chromosome screening methods, applicable to single cells biopsied from preimplantation embryos, allow reliable identification and transfer of euploid embryos. Recently, randomised trials using such methods have indicated that aneuploidy screening improves IVF success rates. However, the high cost of testing has restricted the availability of this potentially beneficial strategy. This study aimed to harness next-generation sequencing (NGS) technology, with the intention of lowering the costs of preimplantation aneuploidy screening. Methods Embryo biopsy, whole genome amplification and semiconductor sequencing. Results A rapid (<15 h) NGS protocol was developed, with consumable cost only two-thirds that of the most widely used method for embryo aneuploidy detection. Validation involved blinded analysis of 54 cells from cell lines or biopsies from human embryos. Sensitivity and specificity were 100%. The method was applied clinically, assisting in the selection of euploid embryos in two IVF cycles, producing healthy children in both cases. The NGS approach was also able to reveal specified mutations in the nuclear or mitochondrial genomes in parallel with chromosome assessment. Interestingly, elevated mitochondrial DNA content was associated with aneuploidy (p<0.05), a finding suggestive of a link between mitochondria and chromosomal malsegregation. Conclusions This study demonstrates that NGS provides highly accurate, low-cost diagnosis of aneuploidy in cells from human preimplantation embryos and is rapid enough to allow testing without embryo cryopreservation. The method described also has the potential to shed light on other aspects of embryo genetics of relevance to health and viability. PMID:25031024

  14. Utilization of teledentistry as a tool to screen for dental caries among 12-year-old school children in a rural region of India.

    PubMed

    Purohit, Bharathi M; Singh, Abhinav; Dwivedi, Ashish

    2017-03-01

    The study aims to assess the reliability of video-graphic method as a tool to screen the dental caries among 12-year-old school children in a rural region of India. A total of 139 school children participated in the study. Visual tactile examinations were conducted using the Decayed, Missing, and Filled Teeth (DMFT) index. Simultaneously, standardized video recording of the oral cavity was performed. Sensitivity and specificity values were calculated for video-graphic assessment of dental caries. Bland-Altman plot was used to assess agreement between the two methods of caries assessment. Likelihood ratio (LR) and receiver-operating characteristic (ROC) curve were used to assess the predictive accuracy of the video-graphic method. Mean DMFT for the study population was 2.47 ± 2.01 and 2.46 ± 1.91 by visual tactile and video-graphic assessment (P = 0.76; > 0.05). Sensitivity and specificity values of 0.86 and 0.58 were established for video-graphic assessment. A fair degree of agreement was noted between the two methods with Intraclass correlation coefficient (ICC) value of 0.56. LR for video-graphic assessment was 2.05. Bland-Altman plot confirmed the level of agreement between the two assessment methods. The area under curve was 0.69 (CI 0.57, 0.80, P = 0.001). Teledentistry examination is comparable to clinical examination when screening for dental caries among school children. This study provides evidence that teledentistry may be used as an alternative screening tool for assessment of dental caries and is viable for remote consultation and treatment planning. Teledentistry offers to change the dynamics of dental care delivery and may effectively bridge the rural-urban oral health divide. © 2016 American Association of Public Health Dentistry.

  15. Interventions for Age-Related Macular Degeneration: Are Practice Guidelines Based on Systematic Reviews?

    PubMed Central

    Lindsley, Kristina; Li, Tianjing; Ssemanda, Elizabeth; Virgili, Gianni; Dickersin, Kay

    2016-01-01

    Topic Are existing systematic reviews of interventions for age-related macular degeneration incorporated into clinical practice guidelines? Clinical relevance High-quality systematic reviews should be used to underpin evidence-based clinical practice guidelines and clinical care. We have examined the reliability of systematic reviews of interventions for age-related macular degeneration (AMD) and described the main findings of reliable reviews in relation to clinical practice guidelines. Methods Eligible publications are systematic reviews of the effectiveness of treatment interventions for AMD. We searched a database of systematic reviews in eyes and vision and employed no language or date restrictions; the database is up-to-date as of May 6, 2014. Two authors independently screened records for eligibility and abstracted and assessed the characteristics and methods of each review. We classified reviews as “reliable” when they reported eligibility criteria, comprehensive searches, appraisal of methodological quality of included studies, appropriate statistical methods for meta-analysis, and conclusions based on results. We mapped treatment recommendations from the American Academy of Ophthalmology Preferred Practice Patterns (AAO PPP) for AMD to the identified systematic reviews and assessed whether any reliable systematic review was cited or could have been cited to support each treatment recommendation. Results Of 1,570 systematic reviews in our database, 47 met our inclusion criteria. Most of the systematic reviews targeted neovascular AMD and investigated anti-vascular endothelial growth factor (anti-VEGF) interventions, dietary supplements or photodynamic therapy. We classified over two-thirds (33/47) of the reports as reliable. The quality of reporting varied, with criteria for reliable reporting met more often for Cochrane reviews and for reviews whose authors disclosed conflicts of interest. Although most systematic reviews were reliable, anti-VEGF agents and photodynamic therapy were the only interventions identified as effective by reliable reviews. Of 35 treatment recommendations extracted from the AAO PPP, 15 could have been supported with reliable systematic reviews; however, only one recommendation had an accompanying intervention systematic review citation, which we assessed as a reliable systematic review. No reliable systematic review was identified for 20 treatment recommendations, highlighting areas of evidence gaps. Conclusions For AMD, reliable systematic reviews exist for many treatment recommendations in the AAO PPP and should be used to support these recommendations. We also identified areas where no high-level evidence exists. Mapping clinical practice guidelines to existing systematic reviews is one way to highlight areas where evidence generation or evidence synthesis is either available or needed. PMID:26804762

  16. A Spanish Validation of the Canadian Adolescent Gambling Inventory (CAGI)

    PubMed Central

    Jiménez-Murcia, Susana; Granero, Roser; Stinchfield, Randy; Tremblay, Joël; del Pino-Gutiérrez, Amparo; Moragas, Laura; Savvidou, Lamprini G.; Fernández-Aranda, Fernando; Aymamí, Neus; Gómez-Peña, Mónica; Tárrega, Salomé; Gunnard, Katarina; Martín-Romera, Virginia; Steward, Trevor; Mestre-Bach, Gemma; Menchón, José M.

    2017-01-01

    Aims: Large-scale epidemiological studies show a significant prevalence of gambling disorder (GD) during adolescence and emerging adulthood, and highlight the need to identify gambling-related behaviors at early ages. However, there are only a handful of screening instruments for this population and many studies measuring youth gambling problems use adult instruments that may not be developmentally appropriate. The aim of this study was to validate a Spanish version of the Canadian Adolescent Gambling Inventory (CAGI) among late adolescent and young adults and to explore its psychometric properties. Methods: The sample (16–29 years old) included a clinical group (n = 55) with GD patients and a control group (n = 340). Results: Exploratory factor analysis yielded one factor as the best model. This 24-item scale demonstrated satisfactory reliability (internal consistency, Cronbach’s alpha, α = 0.91), satisfactory convergent validity as measured by correlation with South Oaks Gambling Screen (r = 0.74), and excellent classification accuracy (AUC = 0.99; sensitivity = 0.98; and specificity = 0.99). Conclusion: Our results provide empirical support for our validation of the Spanish version of the CAGI. We uphold that the Spanish CAGI can be used as a brief, reliable, and valid instrument to assess gambling problems in Spanish youth. PMID:28223961

  17. Validity and sensitivity of the longitudinal asymmetry index to detect gait asymmetry using Microsoft Kinect data.

    PubMed

    Auvinet, E; Multon, F; Manning, V; Meunier, J; Cobb, J P

    2017-01-01

    Gait asymmetry information is a key point in disease screening and follow-up. Constant Relative Phase (CRP) has been used to quantify within-stride asymmetry index, which requires noise-free and accurate motion capture, which is difficult to obtain in clinical settings. This study explores a new index, the Longitudinal Asymmetry Index (ILong) which is derived using data from a low-cost depth camera (Kinect). ILong is based on depth images averaged over several gait cycles, rather than derived joint positions or angles. This study aims to evaluate (1) the validity of CRP computed with Kinect, (2) the validity and sensitivity of ILong for measuring gait asymmetry based solely on data provided by a depth camera, (3) the clinical applicability of a posteriorly mounted camera system to avoid occlusion caused by the standard front-fitted treadmill consoles and (4) the number of strides needed to reliably calculate ILong. The gait of 15 subjects was recorded concurrently with a marker-based system (MBS) and Kinect, and asymmetry was artificially reproduced by introducing a 5cm sole attached to one foot. CRP computed with Kinect was not reliable. ILong detected this disturbed gait reliably and could be computed from a posteriorly placed Kinect without loss of validity. A minimum of five strides was needed to achieve a correlation coefficient of 0.9 between standard MBS and low-cost depth camera based ILong. ILong provides a clinically pragmatic method for measuring gait asymmetry, with application for improved patient care through enhanced disease, screening, diagnosis and monitoring. Copyright © 2016. Published by Elsevier B.V.

  18. Delirium assessment in hospitalized elderly patients: Italian translation and validation of the nursing delirium screening scale.

    PubMed

    Spedale, Valentina; Di Mauro, Stefania; Del Giorno, Giulia; Barilaro, Monica; Villa, Candida E; Gaudreau, Jean D; Ausili, Davide

    2017-08-01

    Delirium has a high incidence pathology associated with negative outcomes. Although highly preventable, half the cases are not recognized. One major cause of delirium misdiagnosis is the absence of a versatile instrument to measure it. Our objective was to translate the nursing delirium screening scale (Nu-DESC) and evaluate its performance in Italian settings. This was a methodological study conducted in two sequential phases. The first was the Italian translation of Nu-DESC through a translation and back-translation process. The second aimed to test the inter-rater reliability, the sensibility and specificity of the instrument on a convenience sample of 101 hospitalized elderly people admitted to relevant wards of the San Gerardo Hospital in Monza. To evaluate the inter-rater reliability, two examiners tested Nu-DESC on 20 patients concurrently without comparison. To measure the sensibility and specificity of Nu-DESC, the confusion assessment method was used as a gold standard measure. The inter-rater reliability (Cohen Kappa) was 0.87-an excellent agreement between examiners. The study of the ROC curve showed an AUC value of 0.9461 suggesting high test accuracy. Using 3 as a cut-off value, Nu-DESC showed 100 % sensibility and 76 % specificity. Further research is needed to test Nu-DESC on a larger sample. However, based on our results, Nu-DESC can be used in research and clinical practice in Italian settings because of its very good and similar performances to previous validation studies. The value of 3 appears to be the optimal cut-off in the Italian context.

  19. General and Specific Approaches to Media Parenting: A Systematic Review of Current Measures, Associations with Screen-Viewing, and Measurement Implications

    PubMed Central

    Edwards, Mark J.; Urbanski, Carly R.; Sebire, Simon J.

    2013-01-01

    Abstract Background Parent-focused interventions may help to reduce youth screen-viewing (SV). This review synthesized current information on the links between parenting styles, parenting practices, and youth SV with a focus on measurement. Methods A systematic review of electronic databases was conducted. Results In all, 29 of 1189 studies met the inclusion criteria. Parenting practices were divided into rule and nonrule-based practices. Seven rules: (1) Limits on total time (n studies=23); (2) limits on time of day (n=7); (3) content restriction (n=11); (4) mealtime rules (n=2); (5) parental supervision (n=3); (6) contingent screentime (n=3); and (7) no-TV policy (n=1) were reported. Two nonrule-based practices were reported: Co-viewing (n=6) and encouragement to view (n=2). Three studies (10.3%) provided information on parenting styles. Only 12 studies (41.4%) provided information on the reliability/validity of the outcome measure, 15 (51.7%) studies provided information on the reliability/validity of the parenting measure, and 6 (20.7%) provided information on the reliability/validity of both outcome and exposure measures. Conclusions There is mixed evidence that parenting styles and media-related parenting practices are associated with youth SV. The assessment of parental influence of youth media use is hampered by the diversity of measures that have been used. There is a need for new measures that assess a range of media parenting practices that are relevant to multiple forms of SV. PMID:23944925

  20. Standing Up a Narcotic Confirmation Laboratory for the Russian Federation Ministry of Defense Nuclear Personnel Reliability Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LukyanenkoMD, Victor; Eisele, Gerhard R; Coates, Cameron W

    2010-01-01

    Through a cooperative effort between the U. S. Department of Energy and the Russian Federation (RF) Ministry of Defense (MOD) a Personnel Reliability Program (PRP) for the nuclear handlers within the RF MOD has been implemented. A key element in the RF MOD PRP is the detection and confirmation of narcotic use in subject military and civilian personnel. This paper describes the process of narcotics screening and testing in the RF MOD and explains the confirmation process once screening has shown a positive result. Issues of laboratory certification, employee certification, employee training, sample chain-of-custody, and equipment needs will be addressed.

Top