Automated turn pike using PLC and SCADA
NASA Astrophysics Data System (ADS)
Silpa Sreedhar, P.; Aiswarya, P.; Kathirvelan, J.
2017-11-01
We propose a smart turnpike based on Programmable Logic Controller (PLC) and Supervisory Control and Data Acquisition Systems (SCADA) in this paper. In this work, the basic idea is to measure the weight of the vehicles and classify them according to its weight to the respective lanes. It is difficult for the turnpike people to monitor the whole process all the time. So, this PLC based diversion system can be implemented in turnpikes to reduce the difficulties. This method will work based on weight sensors (piezo-resistive) whose output will be fed to a PLC, which will control the vehicle diversion. Using SCADA software, the whole process can be monitored from a remote area. The algorithm developed in this successfully installed in real time system.
Acceptance Testing of a Satellite SCADA Photovoltaic-Diesel Hybrid System
NASA Technical Reports Server (NTRS)
Kalu, Alex; Acosta, R.; Durand, S.; Emrich, Carol; Ventre, G.; Wilson, W.
1999-01-01
Savannah State University (SSU) and the Florida Solar Energy Center (FSEC) have been participating in the NASA Advanced Communications Technology Satellite (ACTS) program for the last five years. This program was designed by NASA to help maintain U.S. leadership in commercial space communications by funding high-risk research, and to flight-test next-generation digital satellite components. Launched in 1993, ACTS is an U.S. government funded technology test-bed that incorporates high power Ka-band transponders, small spot beams, and on-board digital storage and switching technology. Associated with the spacecraft, is a prototype satellite control center that supports various application experiments. The SSU/FSEC application experiment is to developing a Photovoltaic-Diesel Hybrid Power system complete with satellite Supervisory Control and Data Acquisition (SCADA). The hybrid system was design to demonstrate the feasibility of using SCADA to maintain and operate remote village power systems. This configuration would enable experts at a central location to provide technical assistance to local technicians while they acquire a measure of proficiency with the hybrid system operation and maintenance. Upon full mastery of the technology, similar SCADA arrangement are planned to remotely monitor and control constellation of hybrid systems scattered overlarge rural areas. Two Orion Energy APEX-1000 hybrid systems were delivered in 1998, one was installed at SSU in eastern Georgia and the other was installed at FSEC in Central Florida. The project was designed to: (1) evaluate the performance of ACTS in a SCADA arrangement, (2) monitor the health and performance of all major hybrid subsystems, (3) investigate load control and battery charging strategies to maximize battery capacity and lifetime, and (4) develop satellite communication protocol. Preliminary results indicate that the hybrid design is suitable for satellite Supervisory Control and Data Acquisition. A modification to the controller software has produced a robust communication link capable of real time control and long term data collection.
Towards a Cyber Defense Framework for SCADA Systems Based on Power Consumption Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez Jimenez, Jarilyn M; Chen, Qian; Nichols, Jeff A.
Supervisory control and data acquisition (SCADA) is an industrial automation system that remotely monitor, and control critical infrastructures. SCADA systems are major targets for espionage and sabotage attackers. According to the 2015 Dell security annual threat report, the number of cyber-attacks against SCADA systems has doubled in the past year. Cyber-attacks (i.e., buffer overflow, rootkits and code injection) could cause serious financial losses and physical infrastructure damages. Moreover, some specific cyber-attacks against SCADA systems could become a threat to human life. Current commercial off-the-shelf security solutions are insufficient in protecting SCADA systems against sophisticated cyber-attacks. In 2014 a report bymore » Mandiant stated that only 69% of organizations learned about their breaches from third entities, meaning that these companies lack of their own detection system. Furthermore, these breaches are not detected in real-time or fast enough to prevent further damages. The average time between compromise and detection (for those intrusions that were detected) was 205 days. To address this challenge, we propose an Intrusion Detection System (IDS) that detects SCADA-specific cyber-attacks by analyzing the power consumption of a SCADA device. Specifically, to validate the proposed approach, we chose to monitor in real-time the power usage of a a Programmable Logic Controller (PLC). To this end, we configured the hardware of the tetsbed by installing the required sensors to monitor and collect its power consumption. After that two SCADA-specific cyber-attacks were simulated and TracerDAQ Pro was used to collect the power consumption of the PLC under normal and anomalous scenarios. Results showed that is possible to distinguish between the regular power usage of the PLC and when the PLC was under specific cyber-attacks.« less
Renewable Energy SCADA/Training Using NASA's Advanced Technology Communication Satellite
NASA Technical Reports Server (NTRS)
Kalu, A.; Emrich, C.; Ventre, G.; Wilson, W.; Acosta, Roberto (Technical Monitor)
2000-01-01
The lack of electrical energy in the rural communities of developing countries is well known, as is the economic unfeasibility of providing much needed energy to these regions via electric grids. Renewable energy (RE) can provide an economic advantage over conventional forms in meeting some of these energy needs. The use of a Supervisory Control and Data Acquisition (SCADA) arrangement via satellite could enable experts at remote locations to provide technical assistance to local trainees while they acquire a measure of proficiency with a newly installed RE system through hands-on training programs using the same communications link. Upon full mastery of the technologies, indigenous personnel could also employ similar SCADA arrangements to remotely monitor and control their constellation of RE systems. Two separate ACTS technology verification experiments (TVEs) have demonstrated that the portability of the Ultra Small Aperture Terminal (USAT) and the versatility of NASA's Advanced Communications Technology Satellite (ACTS), as well as the advantages of Ka band satellites, can be invaluable in providing energy training via distance education (DE), and for implementing renewable energy system SCADA. What has not been tested is the capabilities of these technologies for a simultaneous implementation of renewable energy DE and SCADA. Such concurrent implementations will be useful for preparing trainees in developing countries for their eventual SCADA operations. The project described in this correspondence is the first effort, to our knowledge, in this specific TVE. The setup for this experiment consists of a one-Watt USAT located at Florida Solar Energy Center (FSEC) connected to two satellite modems tuned to different frequencies to establish two duplex ACTS Ka-band communication channels. A short training program on operation and maintenance of the system will be delivered while simultaneously monitoring and controlling the hybrid using the same satellite communications link. The trainees will include faculty and students from Savannah State University, and staff from FSEC. An interactive internet link will be used to allow faculty from the University of West Indies to participate in the training session.
A Web-Based Remote Access Laboratory Using SCADA
ERIC Educational Resources Information Center
Aydogmus, Z.; Aydogmus, O.
2009-01-01
The Internet provides an opportunity for students to access laboratories from outside the campus. This paper presents a Web-based remote access real-time laboratory using SCADA (supervisory control and data acquisition) control. The control of an induction motor is used as an example to demonstrate the effectiveness of this remote laboratory,…
Parris Island Wastewater Treatment Plant SCADA Upgrades Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meador, Richard J.; Hatley, Darrel D.
2004-03-18
Marine Corp Recruit Depot (MCRD), Parris Island, SC, home of the Easter Recruiting Region Marine Corp Boot Camp, found itself in a situation common to Department of Defense (DOD) facilities. It had to deal with several different types of installed energy-related control systems that could not talk to each other. This situation was being exacerbated by the installation of a new and/or unique type of control system for every new building being constructed or older facility that was being upgraded. The Wastewater Treatment Facility (WWTF) and lift station controls were badly in need of a thorough inspection and a newmore » Supervisory Control and Data Acquisition (SCADA) system upgrade to meet environmental, safety, manpower, and maintenance concerns. A project was recently completed to implement such a wastewater treatment SCADA upgrade, which is compatible with other upgrades to the energy monitoring and control systems for Parris Island buildings and the Pacific Northwest National Laboratory (PNNL) Decision Support for Operations and Maintenance (DSOM) system installed at the Central Energy Plant (CEP). This project included design, specification, procurement, installation, and testing an upgraded SCADA alarm, process monitoring, and display system; and training WWTF operators in its operation. The ultimate goal of this and the other PNNL projects at Parris Island is to allow monitoring and control of energy and environmental components from a central location.« less
Quantifying Availability in SCADA Environments Using the Cyber Security Metric MFC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aissa, Anis Ben; Rabai, Latifa Ben Arfa; Abercrombie, Robert K
2014-01-01
Supervisory Control and Data Acquisition (SCADA) systems are distributed networks dispersed over large geographic areas that aim to monitor and control industrial processes from remote areas and/or a centralized location. They are used in the management of critical infrastructures such as electric power generation, transmission and distribution, water and sewage, manufacturing/industrial manufacturing as well as oil and gas production. The availability of SCADA systems is tantamount to assuring safety, security and profitability. SCADA systems are the backbone of the national cyber-physical critical infrastructure. Herein, we explore the definition and quantification of an econometric measure of availability, as it applies tomore » SCADA systems; our metric is a specialization of the generic measure of mean failure cost.« less
Design and development of an IoT-based web application for an intelligent remote SCADA system
NASA Astrophysics Data System (ADS)
Kao, Kuang-Chi; Chieng, Wei-Hua; Jeng, Shyr-Long
2018-03-01
This paper presents a design of an intelligent remote electrical power supervisory control and data acquisition (SCADA) system based on the Internet of Things (IoT), with Internet Information Services (IIS) for setting up web servers, an ASP.NET model-view- controller (MVC) for establishing a remote electrical power monitoring and control system by using responsive web design (RWD), and a Microsoft SQL Server as the database. With the web browser connected to the Internet, the sensing data is sent to the client by using the TCP/IP protocol, which supports mobile devices with different screen sizes. The users can provide instructions immediately without being present to check the conditions, which considerably reduces labor and time costs. The developed system incorporates a remote measuring function by using a wireless sensor network and utilizes a visual interface to make the human-machine interface (HMI) more instinctive. Moreover, it contains an analog input/output and a basic digital input/output that can be applied to a motor driver and an inverter for integration with a remote SCADA system based on IoT, and thus achieve efficient power management.
Internet SCADA Utilizing API's as Data Source
NASA Astrophysics Data System (ADS)
Robles, Rosslin John; Kim, Haeng-Kon; Kim, Tai-Hoon
An Application programming interface or API is an interface implemented by a software program that enables it to interact with other software. Many companies provide free API services which can be utilized in Control Systems. SCADA is an example of a control system and it is a system that collects data from various sensors at a factory, plant or in other remote locations and then sends this data to a central computer which then manages and controls the data. In this paper, we designed a scheme for Weather Condition in Internet SCADA Environment utilizing data from external API services. The scheme was designed to double check the weather information in SCADA.
Remote Supervision and Control of Air Conditioning Systems in Different Modes
NASA Astrophysics Data System (ADS)
Rafeeq, Mohammed; Afzal, Asif; Rajendra, Sree
2018-01-01
In the era of automation, most of the application of engineering and science are interrelated with system for optimal operation. To get the efficient result of an operation and desired response, interconnected systems should be controlled by directing, regulating and commanding. Here, air conditioning (AC) system is considered for experimentation, to supervise and control its functioning in both, automated and manual mode. This paper reports the work intended to design and develop an automated and manual AC system working in remote and local mode, to increase the level of comfort, easy operation, reducing human intervention and faults occurring in the system. The Programmable Logical Controller (PLC) and Supervisory Control and Data Acquisition (SCADA) system were used for remote supervision and monitoring of AC systems using series ninety protocol and remote terminal unit modbus protocol as communication module to operate in remote mode. PLC was used as remote terminal for continuous supervision and control of AC system. SCADA software was used as a tool for designing user friendly graphical user interface. The proposed SCADA AC system successfully monitors and controls in accordance within the parameter limits like temperature, pressure, humidity and voltage. With all the features, this designed system is capable of efficient handling of the resources like the compressor, humidifier etc., with all the levels of safety and durability. This system also maintains the temperature and controls the humidity of the remote location and also looks after the health of the compressor.
NASA Astrophysics Data System (ADS)
Zulfikar, Can; Pinar, Ali; Tunc, Suleyman; Erdik, Mustafa
2014-05-01
The Istanbul EEW network consisting of 10 inland and 5 OBS strong motion stations located close to the Main Marmara Fault zone is operated by KOERI. Data transmission between the remote stations and the base station at KOERI is provided both with satellite and fiber optic cable systems. The continuous on-line data from these stations is used to provide real time warning for emerging potentially disastrous earthquakes. The data transmission time from the remote stations to the KOERI data center is a few milliseconds through fiber optic lines and less than a second via satellites. The early warning signal (consisting three alarm levels) is communicated to the appropriate servo shut-down systems of the receipent facilities, that automatically decide proper action based on the alarm level. Istanbul Gas Distribution Corporation (IGDAS) is one of the end users of the EEW signal. IGDAS, the primary natural gas provider in Istanbul, operates an extensive system 9,867 km of gas lines with 550 district regulators and 474,000 service boxes. State of-the-art protection systems automatically cut natural gas flow when breaks in the pipelines are detected. Since 2005, buildings in Istanbul using natural gas are required to install seismometers that automatically cut natural gas flow when certain thresholds are exceeded. IGDAS uses a sophisticated SCADA (supervisory control and data acquisition) system to monitor the state-of-health of its pipeline network. This system provides real-time information about quantities related to pipeline monitoring, including input-output pressure, drawing information, positions of station and RTU (remote terminal unit) gates, slum shut mechanism status at 581 district regulator sites. The SCADA system of IGDAŞ receives the EEW signal from KOERI and decide the proper actions according to the previously specified ground acceleration levels. Presently, KOERI sends EEW signal to the SCADA system of IGDAS Natural Gas Network of Istanbul. The EEW signal of KOERI is also transmitted to the serve shut down system of the Marmaray Rail Tube Tunnel and Commuter Rail Mass Transit System in Istanbul. The Marmaray system includes an undersea railway tunnel under the Bosphorus Strait. Several strong motion instruments are installed within the tunnel for taking measurements against strong ground shaking and early warning purposes. This system is integrated with the KOERI EEW System. KOERI sends the EEW signal to the command center of Marmaray. Having received the signal, the command center put into action the previously defined measurements. For example, the trains within the tunnel will be stopped at the nearest station, no access to the tunnel will be allowed to the trains approaching the tunnel, water protective caps will be closed to protect flood closing the connection between the onshore and offshore tunnels.
Fundamentals of SCADA and automated meter reading
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwok, A.
1992-02-01
This paper discusses SCADA systems allow users to control and acquire data from remote facilities such as compressors, pressure-regulating stations, control valves and measurement stations. In general, a SCADA system performs functions in sequential control, continuous control, supervisory setpoint control and data acquisitions. AMR systems allow users to obtain up-to-date information on their gas demand. When AMR was in its infancy, equipment was designed only to read and record gas consumption values. The basic function of an early AMR system was to read gas volume at a fixed interval and record the data in its memory until it communicated withmore » a central receiving facility.« less
Code of Federal Regulations, 2014 CFR
2014-01-01
... where a telecommunications provider houses a device that combines individual subscriber circuits onto a... Control and Data Acquisition System (SCADA). Electronic monitoring and control equipment installed at...
Code of Federal Regulations, 2012 CFR
2012-01-01
... where a telecommunications provider houses a device that combines individual subscriber circuits onto a... Control and Data Acquisition System (SCADA). Electronic monitoring and control equipment installed at...
Code of Federal Regulations, 2011 CFR
2011-01-01
... where a telecommunications provider houses a device that combines individual subscriber circuits onto a... Control and Data Acquisition System (SCADA). Electronic monitoring and control equipment installed at...
Code of Federal Regulations, 2013 CFR
2013-01-01
... where a telecommunications provider houses a device that combines individual subscriber circuits onto a... Control and Data Acquisition System (SCADA). Electronic monitoring and control equipment installed at...
Pipeline scada upgrade uses satellite terminal system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conrad, W.; Skovrinski, J.R.
In the recent automation of its supervisory control and data acquisition (scada) system, Transwestern Pipeline Co. has become the first to use very small aperture satellite terminals (VSAT's) for scada. A subsidiary of Enron Interstate Pipeline, Houston, Transwestern moves natural gas through a 4,400-mile system from West Texas, New Mexico, and Oklahoma to southern California markets. Transwestern's modernization, begun in November 1985, addressed problems associated with its aging control equipment which had been installed when the compressor stations were built in 1960. Over the years a combination of three different systems had been added. All were cumbersome to maintain andmore » utilized outdated technology. Problems with reliability, high maintenance time, and difficulty in getting new parts were determining factors in Transwestern's decision to modernize its scada system. In addition, the pipeline was anticipating moving its control center from Roswell, N.M., to Houston and believed it would be impossible to marry the old system with the new computer equipment in Houston.« less
Code of Federal Regulations, 2011 CFR
2011-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2010 CFR
2010-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2013 CFR
2013-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2014 CFR
2014-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2012 CFR
2012-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Control of Smart Building Using Advanced SCADA
NASA Astrophysics Data System (ADS)
Samuel, Vivin Thomas
For complete control of the building, a proper SCADA implementation and the optimization strategy has to be build. For better communication and efficiency a proper channel between the Communication protocol and SCADA has to be designed. This paper concentrate mainly between the communication protocol, and the SCADA implementation, for a better optimization and energy savings is derived to large scale industrial buildings. The communication channel used in order to completely control the building remotely from a distant place. For an efficient result we consider the temperature values and the power ratings of the equipment so that while controlling the equipment, we are setting a threshold values for FDD technique implementation. Building management system became a vital source for any building to maintain it and for safety purpose. Smart buildings, refers to various distinct features, where the complete automation system, office building controls, data center controls. ELC's are used to communicate the load values of the building to the remote server from a far location with the help of an Ethernet communication channel. Based on the demand fluctuation and the peak voltage, the loads operate differently increasing the consumption rate thus results in the increase in the annual consumption bill. In modern days, saving energy and reducing the consumption bill is most essential for any building for a better and long operation. The equipment - monitored regularly and optimization strategy is implemented for cost reduction automation system. Thus results in the reduction of annual cost reduction and load lifetime increase.
2015-05-01
application ,1 while the simulated PLC software is the open source ModbusPal Java application . When queried using the Modbus TCP protocol, ModbusPal reports...and programmable logic controller ( PLC ) components. The HMI and PLC components were instantiated with software and installed in multiple virtual...creating and capturing HMI– PLC network traffic over a 24-h period in the virtualized network and inspect the packets for errors. Test the
Towards a Standard for Highly Secure SCADA Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, R.
1998-09-25
The critical energy inkstructures include gas, OL and electric power. These Mrastructures are complex and interdependent nmvorks that are vital to the national secwiy and social well being of our nation. Many electric power systems depend upon gas and oil, while fossil energy delive~ systems depend upon elecnic power. The control mechanisms for these Mrastructures are often referred to as SCADA (Supmivry CkmdandDaU Ac@itz&z) systems. SCADA systems provide remote monitoring and centralized control for a distributed tmnsportation infmsmucture in order to facilitate delivery of a commodi~. AIthough many of the SCADA concepts developed in this paper can be applied tomore » automotive mmsponation systems, we will use transportation to refer to the movement of electrici~, gas, and oil. \\ Recently, there have been seveml reports suggesting that the widespread and increasing use of SCADA for control of energy systems provides an increasing opportuni~ for an advers~ to cause serious darnage to the energy inbstmcturei~. This damage could arise through cyber infiltration of the SCADA networks, by physically tampering with the control networks, or through a combination of both means. SCADA system threats decompose into cyber and physical threats. One solution to the SCADA security problem is to design a standard for a highly secure KA.DA system that is both cyber, and physdly secure. Not all-physical threats are possible to guard again% but of those threats that are, high security SCADA provides confidence that the system will continue to operate in their presence. One of the most important problems in SCADA securi~ is the relationship between the cyber and physical vulnerabilities. Cyber intrusion increases physical Vulnerabilities, while in the dual problem physical tampering increases cyber vulnerabilit.ies. There is potential for feedback and the precise dynamics need to be understood. As a first step towards a stan~ the goal of this paper is to facilitate a discussion of the requirements analysis for a highly secure SCADA system. The fi-arnework for the discussion consists of the identification of SCADA security investment areas coupled with the tradeoffs that will force compromises in the solution. For example, computational and bandwidth requirements of a security standard could force the replacement of entire SCADA systems. The requirements for a real-time response in a cascading electric power failure could pose limitations on authentication and encryption mechanisms. The shortest path to the development of a high securi~ SC.ADA standard will be achieved by leveraging existing standards efforts and ensuring that security is being properly addressed in those standards. The Utility Communications Architecture 2.o (UC@, for real-time utili~ decision control, represents one such standard. The development of a SCADA secwiy specification is a complex task that will benefit from a systems engineering approach.« less
Quantifying the Impact of Unavailability in Cyber-Physical Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aissa, Anis Ben; Abercrombie, Robert K; Sheldon, Federick T.
2014-01-01
The Supervisory Control and Data Acquisition (SCADA) system discussed in this work manages a distributed control network for the Tunisian Electric & Gas Utility. The network is dispersed over a large geographic area that monitors and controls the flow of electricity/gas from both remote and centralized locations. The availability of the SCADA system in this context is critical to ensuring the uninterrupted delivery of energy, including safety, security, continuity of operations and revenue. Such SCADA systems are the backbone of national critical cyber-physical infrastructures. Herein, we propose adapting the Mean Failure Cost (MFC) metric for quantifying the cost of unavailability.more » This new metric combines the classic availability formulation with MFC. The resulting metric, so-called Econometric Availability (EA), offers a computational basis to evaluate a system in terms of the gain/loss ($/hour of operation) that affects each stakeholder due to unavailability.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pollet, J.
2006-07-01
This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-criticalmore » networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)« less
Acceptance Testing of a Satellite SCADA Photovoltaic-Diesel Hybrid System
NASA Technical Reports Server (NTRS)
Kalu, A.; Emrich, C.; Ventre, G.; Wilson, W.; Acosta, Roberto (Technical Monitor)
2000-01-01
Satellite Supervisory Control and Data Acquisition (SCADA) of a Photovoltaic (PV)/diesel hybrid system was tested using NASA's Advanced Communication Technology Satellite (ACTS) and Ultra Small Aperture Terminal (USAT) ground stations. The setup consisted of a custom-designed PV/diesel hybrid system, located at the Florida Solar Energy Center (FSEC), which was controlled and monitored at a "remote" hub via Ka-band satellite link connecting two 1/4 Watt USATs in a SCADA arrangement. The robustness of the communications link was tested for remote monitoring of the health and performance of a PV/diesel hybrid system, and for investigating load control and battery charging strategies to maximize battery capacity and lifetime, and minimize loss of critical load probability. Baseline hardware performance test results demonstrated that continuous two-second data transfers can be accomplished under clear sky conditions with an error rate of less than 1%. The delay introduced by the satellite (1/4 sec) was transparent to synchronization of satellite modem as well as to the PV/diesel-hybrid computer. End-to-end communications link recovery times were less than 36 seconds for loss of power and less than one second for loss of link. The system recovered by resuming operation without any manual intervention, which is important since the 4 dB margin is not sufficient to prevent loss of the satellite link during moderate to heavy rain. Hybrid operations during loss of communications link continued seamlessly but real-time monitoring was interrupted. For this sub-tropical region, the estimated amount of time that the signal fade will exceed the 4 dB margin is about 10%. These results suggest that data rates of 4800 bps and a link margin of 4 dB with a 1/4 Watt transmitter are sufficient for end-to-end operation in this SCADA application.
Applying Water-Level Difference Control to Central Arizona Project
USDA-ARS?s Scientific Manuscript database
The Central Arizona Project (CAP) has been supplying Colorado River water to Central Arizona for roughly 25 years. The CAP canal is operated remotely with a Supervisory Control and Data Acquisition (SCADA) System. Gate position changes are made either manually or through the use of automatic control...
Kerman Photovoltaic Power Plant R&D data collection computer system operations and maintenance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosen, P.B.
1994-06-01
The Supervisory Control and Data Acquisition (SCADA) system at the Kerman PV Plant monitors 52 analog, 44 status, 13 control, and 4 accumulator data points in real-time. A Remote Terminal Unit (RTU) polls 7 peripheral data acquisition units that are distributed throughout the plant once every second, and stores all analog, status, and accumulator points that have changed since the last scan. The R&D Computer, which is connected to the SCADA RTU via a RS-232 serial link, polls the RTU once every 5-7 seconds and records any values that have changed since the last scan. A SCADA software package calledmore » RealFlex runs on the R&D computer and stores all updated data values taken from the RTU, along with a time-stamp for each, in a historical real-time database. From this database, averages of all analog data points and snapshots of all status points are generated every 10 minutes and appended to a daily file. These files are downloaded via modem by PVUSA/Davis staff every day, and the data is placed into the PVUSA database.« less
Carrasco, Juan A; Dormido, Sebastián
2006-04-01
The use of industrial control systems in simulators facilitates the execution of engineering activities related with the installation and the optimization of the control systems in real plants. "Industrial control system" intends to be a valid term that would represent all the control systems which can be installed in an industrial plant, ranging from complex distributed control systems and SCADA packages to small single control devices. This paper summarizes the current alternatives for the development of simulators of industrial plants and presents an analysis of the process of integrating an industrial control system into a simulator, with the aim of helping in the installation of real control systems in simulators.
Programmable logic controller optical fibre sensor interface module
NASA Astrophysics Data System (ADS)
Allwood, Gary; Wild, Graham; Hinckley, Steven
2011-12-01
Most automated industrial processes use Distributed Control Systems (DCSs) or Programmable Logic Controllers (PLCs) for automated control. PLCs tend to be more common as they have much of the functionality of DCSs, although they are generally cheaper to install and maintain. PLCs in conjunction with a human machine interface form the basis of Supervisory Control And Data Acquisition (SCADA) systems, combined with communication infrastructure and Remote Terminal Units (RTUs). RTU's basically convert different sensor measurands in to digital data that is sent back to the PLC or supervisory system. Optical fibre sensors are becoming more common in industrial processes because of their many advantageous properties. Being small, lightweight, highly sensitive, and immune to electromagnetic interference, means they are an ideal solution for a variety of diverse sensing applications. Here, we have developed a PLC Optical Fibre Sensor Interface Module (OFSIM), in which an optical fibre is connected directly to the OFSIM located next to the PLC. The embedded fibre Bragg grating sensors, are highly sensitive and can detect a number of different measurands such as temperature, pressure and strain without the need for a power supply.
Architecture and Methods for Substation SCADA Cybersecurity: Best Practices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Albunashee, Hamdi; Al Sarray, Muthanna; McCann, Roy
There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize themore » R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thaule, S.B.; Postvoll, W.
Installation by den norske stats oljeselskap A.S. (Statoil) of a powerful pipeline-modeling system on Zeepipe has allowed this major North Sea gas pipeline to meet the growing demands and seasonal variations of the European gas market. The Troll gas-sales agreement (TGSA) in 1986 called for large volumes of Norwegian gas to begin arriving from the North Sea Sleipner East field in october 1993. It is important to Statoil to maintain regular gas delivers from its integrated transport network. In addition, high utilization of transport capacity maximizes profits. In advance of operations, Statoil realized that state-of-the-art supervisory control and data acquisitionmore » (scada) and pipeline-modeling systems (PMS) would be necessary to meet its goals and to remain the most efficient North Sea operator. The paper describes the linking of Troll and Zeebrugge, contractual issues, the supervisory system, the scada module, pipeline modeling, real-time model, look-ahead model, predictive model, and model performance.« less
Wind Power Plant SCADA and Controls
DOE Office of Scientific and Technical Information (OSTI.GOV)
Badrzadeh, Babak; Castillo, Nestor; Bradt, M.
2011-01-01
Modern Wind Power Plants (WPPs) contain a variety of intelligent electronic devices (IEDs), Supervisory Control and Data Acquisition (SCADA) and communication systems. This paper discusses the issues related to a typical WPP's SCADA and Control. Presentation topics are: (1) Wind Turbine Controls; (2) Wind Plant SCADA, OEM SCADA Solutions, Third-Party SCADA Solutions; (3) Wind Plant Control; and (4) Security and Reliability Compliance.
A project of upgrading the operations control system of the Hungarian electric power system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oroszki, L.; Kovacs, G.
About 20 years ago an on-line EMS/SCADA system replaced the previously used off-line control system in the Hungarian power system. The system that has met the technological requirements of that time now became obsolete. A project started in 1995 by the Hungarian Power Companies, Ltd. (MVM Rt.), the regional utility companies and the power plant companies, with funding through a World Bank loan to cover international procurement, aims to upgrade that system into a complex, intelligent and state-of-the-art process control system. The new hierarchical system will rely on a distributed computer network structure, universally accepted hardware/software interface standards and communicationmore » protocols and use hardware platform independent software. The automatic generation control, performed from the National Dispatch Centre, will have expanded functionality, the most important single item of this will be the inclusion of automatic voltage/var control. The upgrading project includes the replacement of the substation and power plant remote terminal units and the installation of a telecommunication network to provide this telecontrol system with the necessary communications links. The supply contracts for both the master station and the remote terminal unit parts were awarded to the winners of open international bidding processes. In the project implementation MVM has the overall responsibility and works with assistance from international and Hungarian engineering firms.« less
An Architecture for SCADA Network Forensics
NASA Astrophysics Data System (ADS)
Kilpatrick, Tim; Gonzalez, Jesus; Chandia, Rodrigo; Papa, Mauricio; Shenoi, Sujeet
Supervisory control and data acquisition (SCADA) systems are widely used in industrial control and automation. Modern SCADA protocols often employ TCP/IP to transport sensor data and control signals. Meanwhile, corporate IT infrastructures are interconnecting with previously isolated SCADA networks. The use of TCP/IP as a carrier protocol and the interconnection of IT and SCADA networks raise serious security issues. This paper describes an architecture for SCADA network forensics. In addition to supporting forensic investigations of SCADA network incidents, the architecture incorporates mechanisms for monitoring process behavior, analyzing trends and optimizing plant performance.
Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon
2016-01-01
Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network. PMID:27314351
Shahzad, Aamir; Landry, René; Lee, Malrey; Xiong, Naixue; Lee, Jongho; Lee, Changhoon
2016-06-14
Substantial changes have occurred in the Information Technology (IT) sectors and with these changes, the demand for remote access to field sensor information has increased. This allows visualization, monitoring, and control through various electronic devices, such as laptops, tablets, i-Pads, PCs, and cellular phones. The smart phone is considered as a more reliable, faster and efficient device to access and monitor industrial systems and their corresponding information interfaces anywhere and anytime. This study describes the deployment of a protocol whereby industrial system information can be securely accessed by cellular phones via a Supervisory Control And Data Acquisition (SCADA) server. To achieve the study goals, proprietary protocol interconnectivity with non-proprietary protocols and the usage of interconnectivity services are considered in detail. They support the visualization of the SCADA system information, and the related operations through smart phones. The intelligent sensors are configured and designated to process real information via cellular phones by employing information exchange services between the proprietary protocol and non-proprietary protocols. SCADA cellular access raises the issue of security flaws. For these challenges, a cryptography-based security method is considered and deployed, and it could be considered as a part of a proprietary protocol. Subsequently, transmission flows from the smart phones through a cellular network.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beaver, Justin M; Borges, Raymond Charles; Buckner, Mark A
Critical infrastructure Supervisory Control and Data Acquisition (SCADA) systems were designed to operate on closed, proprietary networks where a malicious insider posed the greatest threat potential. The centralization of control and the movement towards open systems and standards has improved the efficiency of industrial control, but has also exposed legacy SCADA systems to security threats that they were not designed to mitigate. This work explores the viability of machine learning methods in detecting the new threat scenarios of command and data injection. Similar to network intrusion detection systems in the cyber security domain, the command and control communications in amore » critical infrastructure setting are monitored, and vetted against examples of benign and malicious command traffic, in order to identify potential attack events. Multiple learning methods are evaluated using a dataset of Remote Terminal Unit communications, which included both normal operations and instances of command and data injection attack scenarios.« less
An Encryption Scheme for Communication Internet SCADA Components
NASA Astrophysics Data System (ADS)
Robles, Rosslin John; Kim, Tai-Hoon
The trend in most systems is that they are connected through the Internet. Traditional Supervisory Control and Data Acquisition Systems (SCADA) is connected only in a limited private network. SCADA is considered a critical infrastructure, and connecting to the internet is putting the society on jeopardy, some operators hold back on connecting it to the internet. But since the internet Supervisory Control and Data Acquisition Systems (SCADA) facility has brought a lot of advantages in terms of control, data viewing and generation. Along with these advantages, are security issues regarding web SCADA, operators are pushed to connect Supervisory Control and Data Acquisition Systems (SCADA) through the internet. Because of this, many issues regarding security surfaced. In this paper, we discuss web SCADA and the issues regarding security. As a countermeasure, a web SCADA security solution using crossed-crypto-scheme is proposed to be used in the communication of SCADA components.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Igure, V. M.; Williams, R. D.
2006-07-01
Supervisory control and data acquisition (SCADA) networks have replaced discrete wiring for many industrial processes, and the efficiency of the network alternative suggests a trend toward more SCADA networks in the future. This paper broadly considers SCADA to include distributed control systems (DCS) and digital control systems. These networks offer many advantages, but they also introduce potential vulnerabilities that can be exploited by adversaries. Inter-connectivity exposes SCADA networks to many of the same threats that face the public internet and many of the established defenses therefore show promise if adapted to the SCADA differences. This paper provides an overview ofmore » security issues in SCADA networks and ongoing efforts to improve the security of these networks. Initially, a few samples from the range of threats to SCADA network security are offered. Next, attention is focused on security assessment of SCADA communication protocols. Three challenges must be addressed to strengthen SCADA networks. Access control mechanisms need to be introduced or strengthened, improvements are needed inside of the network to enhance security and network monitoring, and SCADA security management improvements and policies are needed. This paper discusses each of these challenges. This paper uses the Profibus protocol as an example to illustrate some of the vulnerabilities that arise within SCADA networks. The example Profibus security assessment establishes a network model and an attacker model before proceeding to a list of example attacks. (authors)« less
2006-09-01
and other forms of Internet research were used to confirm the relevance of the OUI to control system reconnaissance. I assigned a subjective level...equipment 4 = Confirmed with Internet research 5 = Suspected with Internet research OUI Organization Confidence Notes 00:00:0A Omron Tateisi...IP Vendor List 2 = Cross Referenced with IANA port list 3 = Confirmed with lab equipment 4 = Confirmed with Internet research 5 = Suspected with
2014-06-16
SCADA systems. These professionals should be aware of the vulnerabilities so they can take intelligent precautions to mitigate attacks. SCADA...vulnerabilities • Describe mitigation options for protecting a system from SCADA attacks For students that go on to pursue a degree in Computer...from SCADA attacks For students who do not remain in the IT realm, this introduction provides an awareness to help them mitigate threats for their
Long-term monitoring of a cable stayed bridge using a SCADA system
NASA Astrophysics Data System (ADS)
Torbol, Marco; Kim, Sehwan; Shinozuka, Masanobu
2012-04-01
DuraMote is a MEMS-based remote sensing system, which is developed for the NIST TIP project, Next Generation SCADA for Prevention and Mitigation of Water System Infrastructure Disaster. It is designed for supervisory control and data acquisition (SCADA) of pipe ruptures in water distribution systems. In this project, a method is developed to detect the pipe ruptures by analyzing the acceleration data gathered by DuraMote which consists of two primary components; the first, "Gopher" contains the accelerometers and are attached to the water pipe surface noninvasively, and the second, "Roocas" is placed above ground supplying the power to, and retrieving the data from the multiple Gophers, and then transmit the data through Wi-Fi to a base station. The relays support the Wi-Fi network to facilitate the transmission. A large scale bridge provides an ideal test-bet to validate the performance of such a complex monitoring system as DuraMote for its accuracy, reliability, robustness, and user friendliness. This is because a large bridge is most of the time subjected to susceptible level of ambient vibration due to passing loads, wind, etc. DuraMote can record the acceleration time history arising from the vibration making it possible to estimate the frequency values of various bridge vibration modes. These estimated frequency values are then compared with the values computed from analytical model of the bridge for the verification of the accuracy of DuraMote. It is noted that such a verification method cannot be used practically by deploying DuraMote on a water distribution network since the dynamic behavior of a pipe network, either above or underground, is too complex to model analytically for this purpose, and in addition, the network generally lacks conveniently recordable ambient vibration. In this experiment, the performance of DuraMote system was tested being installed on the Hwamyung Bridge, a 500 m long RC cable stayed bridge in Korea for long term monitoring. In total, the system consisted of 24 accelerometers, 13 Gophers, 10 Roocas, 5 relays, and 1 base station. As it happened, the bridge was subjected to heavy rain, winds, and a typhoon during the experiment allowing the DuraMote to demonstrate extra ordinary robustness and durability. Indeed, in spite of the rough weather, acceleration data was continuously recorded from which natural frequencies, mode shapes, and other structural parameters were calculated. This opportunity would not have happened if the experiment was planned for a shorter duration.
Mobile phone based SCADA for industrial automation.
Ozdemir, Engin; Karacor, Mevlut
2006-01-01
SCADA is the acronym for "Supervisory Control And Data Acquisition." SCADA systems are widely used in industry for supervisory control and data acquisition of industrial processes. Conventional SCADA systems use PC, notebook, thin client, and PDA as a client. In this paper, a Java-enabled mobile phone has been used as a client in a sample SCADA application in order to display and supervise the position of a sample prototype crane. The paper presents an actual implementation of the on-line controlling of the prototype crane via mobile phone. The wireless communication between the mobile phone and the SCADA server is performed by means of a base station via general packet radio service (GPRS) and wireless application protocol (WAP). Test results have indicated that the mobile phone based SCADA integration using the GPRS or WAP transfer scheme could enhance the performance of the crane in a day without causing an increase in the response times of SCADA functions. The operator can visualize and modify the plant parameters using his mobile phone, without reaching the site. In this way maintenance costs are reduced and productivity is increased.
An Architectural Framework for Describing Supervisory Control and Data Acquisition (SCADA) Systems
2004-09-01
having one of two possible values, described as 0 or 1. Boundary A logical segregation of related components in a system. The segregation may be based ...Depending on the sophistication of the microcontroller in the RTU, it can be configured to act as a relay station for other RTUs which cannot...communicate directly with a master station, or the microcontroller can communicate on a peer-to-peer basis with other RTUs. RTUs are generally remotely
NASA Astrophysics Data System (ADS)
Dulǎu, Lucian Ioan
2015-12-01
This paper describes the simulation of a microgrid system with storage technologies. The microgrid comprises 6 distributed generators (DGs), 3 loads and a 150 kW storage unit. The installed capacity of the generators is 1100 kW, while the total load demand is 900 kW. The simulation is performed by using a SCADA software, considering the power generation costs, the loads demand and the system's power losses. The generators access the system in order of their power generation cost. The simulation is performed for the entire day.
Cybersecurity of Critical Control Networks
2015-07-14
project are included below. The tasks include work in link encryption for existing legacy SCADA equipment, where we continue to develop lightweight...language for authoring and monitoring compliance of SCADA systems, including technologies for a “policy monitor” which reports out on any observance issues...Acquisition ( SCADA ). Details of each project are included below. The tasks include work in link encryption for existing legacy SCADA equipment
Security Encryption Scheme for Communication of Web Based Control Systems
NASA Astrophysics Data System (ADS)
Robles, Rosslin John; Kim, Tai-Hoon
A control system is a device or set of devices to manage, command, direct or regulate the behavior of other devices or systems. The trend in most systems is that they are connected through the Internet. Traditional Supervisory Control and Data Acquisition Systems (SCADA) is connected only in a limited private network Since the internet Supervisory Control and Data Acquisition Systems (SCADA) facility has brought a lot of advantages in terms of control, data viewing and generation. Along with these advantages, are security issues regarding web SCADA, operators are pushed to connect Control Systems through the internet. Because of this, many issues regarding security surfaced. In this paper, we discuss web SCADA and the issues regarding security. As a countermeasure, a web SCADA security solution using crossed-crypto-scheme is proposed to be used in the communication of SCADA components.
Behavioral Profiling of Scada Network Traffic Using Machine Learning Algorithms
2014-03-27
BEHAVIORAL PROFILING OF SCADA NETWORK TRAFFIC USING MACHINE LEARNING ALGORITHMS THESIS Jessica R. Werling, Captain, USAF AFIT-ENG-14-M-81 DEPARTMENT...subject to copyright protection in the United States. AFIT-ENG-14-M-81 BEHAVIORAL PROFILING OF SCADA NETWORK TRAFFIC USING MACHINE LEARNING ...AFIT-ENG-14-M-81 BEHAVIORAL PROFILING OF SCADA NETWORK TRAFFIC USING MACHINE LEARNING ALGORITHMS Jessica R. Werling, B.S.C.S. Captain, USAF Approved
Study on the Future Internet System through Analysis of SCADA Systems
NASA Astrophysics Data System (ADS)
Song, Jae-Gu; Jung, Sungmo; Kim, Seoksoo
Research on the future Internet is focused on establishing standards by solving problems through various projects and accepting various requirements. In this study, the SCADA (Supervisory Control And Data Acquisition) environment, closely related with national infrastructure, is analyzed in order to explore requirements of the future Internet and then those of the SCADA network. Also, this study provides SCADA system environments for the future Internet.
Using State Estimation Residuals to Detect Abnormal SCADA Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Jian; Chen, Yousu; Huang, Zhenyu
2010-04-30
Detection of abnormal supervisory control and data acquisition (SCADA) data is critically important for safe and secure operation of modern power systems. In this paper, a methodology of abnormal SCADA data detection based on state estimation residuals is presented. Preceded with a brief overview of outlier detection methods and bad SCADA data detection for state estimation, the framework of the proposed methodology is described. Instead of using original SCADA measurements as the bad data sources, the residuals calculated based on the results of the state estimator are used as the input for the outlier detection algorithm. The BACON algorithm ismore » applied to the outlier detection task. The IEEE 118-bus system is used as a test base to evaluate the effectiveness of the proposed methodology. The accuracy of the BACON method is compared with that of the 3-σ method for the simulated SCADA measurements and residuals.« less
Real-Time SCADA Cyber Protection Using Compression Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyle G. Roybal; Gordon H Rueff
2013-11-01
The Department of Energy’s Office of Electricity Delivery and Energy Reliability (DOE-OE) has a critical mission to secure the energy infrastructure from cyber attack. Through DOE-OE’s Cybersecurity for Energy Delivery Systems (CEDS) program, the Idaho National Laboratory (INL) has developed a method to detect malicious traffic on Supervisory, Control, and Data Acquisition (SCADA) network using a data compression technique. SCADA network traffic is often repetitive with only minor differences between packets. Research performed at the INL showed that SCADA network traffic has traits desirable for using compression analysis to identify abnormal network traffic. An open source implementation of a Lempel-Ziv-Welchmore » (LZW) lossless data compression algorithm was used to compress and analyze surrogate SCADA traffic. Infected SCADA traffic was found to have statistically significant differences in compression when compared against normal SCADA traffic at the packet level. The initial analyses and results are clearly able to identify malicious network traffic from normal traffic at the packet level with a very high confidence level across multiple ports and traffic streams. Statistical differentiation between infected and normal traffic level was possible using a modified data compression technique at the 99% probability level for all data analyzed. However, the conditions tested were rather limited in scope and need to be expanded into more realistic simulations of hacking events using techniques and approaches that are better representative of a real-world attack on a SCADA system. Nonetheless, the use of compression techniques to identify malicious traffic on SCADA networks in real time appears to have significant merit for infrastructure protection.« less
NASA Astrophysics Data System (ADS)
Adrian-Lucian, Cococeanu; Ioana-Alina, Cretan; Ivona, Cojocinescu Mihaela; Teodor Eugen, Man; Narcis, Pelea George
2017-10-01
The water supply system in Timisoara Municipality is insured with about 25-30 % of the water demand from wells. The underground water headed to the water treatment plant in order to ensure equal distribution and pressure to consumers. The treatment plants used are Urseni and Ronaţ, near Timisoara, in Timis County. In Timisoara groundwater represents an alternative source for water supply and complementary to the surface water source. The present paper presents a case study with proposal and solutions for rehabilitation /equipment /modernization/ automation of water drilling in order to ensure that the entire system can be monitored and controlled remotely through SCADA (Supervisory control and data acquisition) system. The data collected from the field are designed for online efficiency monitoring regarding the energy consumption and water flow intake, performance indicators such as specific energy consumption KW/m3 and also in order to create a hydraulically system of the operating area to track the behavior of aquifers in time regarding the quality and quantity aspects.
Sandia SCADA Program -- High Surety SCADA LDRD Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
CARLSON, ROLF E.
2002-04-01
Supervisory Control and Data Acquisition (SCADA) systems are a part of the nation's critical infrastructure that is especially vulnerable to attack or disruption. Sandia National Laboratories is developing a high-security SCADA specification to increase the national security posture of the U.S. Because SCADA security is an international problem and is shaped by foreign and multinational interests, Sandia is working to develop a standards-based solution through committees such as the IEC TC 57 WG 15, the IEEE Substation Committee, and the IEEE P1547-related activity on communications and controls. The accepted standards are anticipated to take the form of a Common Criteriamore » Protection Profile. This report provides the status of work completed and discusses several challenges ahead.« less
Design and Development of Layered Security: Future Enhancements and Directions in Transmission
Shahzad, Aamir; Lee, Malrey; Kim, Suntae; Kim, Kangmin; Choi, Jae-Young; Cho, Younghwa; Lee, Keun-Kwang
2016-01-01
Today, security is a prominent issue when any type of communication is being undertaken. Like traditional networks, supervisory control and data acquisition (SCADA) systems suffer from a number of vulnerabilities. Numerous end-to-end security mechanisms have been proposed for the resolution of SCADA-system security issues, but due to insecure real-time protocol use and the reliance upon open protocols during Internet-based communication, these SCADA systems can still be compromised by security challenges. This study reviews the security challenges and issues that are commonly raised during SCADA/protocol transmissions and proposes a secure distributed-network protocol version 3 (DNP3) design, and the implementation of the security solution using a cryptography mechanism. Due to the insecurities found within SCADA protocols, the new development consists of a DNP3 protocol that has been designed as a part of the SCADA system, and the cryptographically derived security is deployed within the application layer as a part of the DNP3 stack. PMID:26751443
Design and Development of Layered Security: Future Enhancements and Directions in Transmission.
Shahzad, Aamir; Lee, Malrey; Kim, Suntae; Kim, Kangmin; Choi, Jae-Young; Cho, Younghwa; Lee, Keun-Kwang
2016-01-06
Today, security is a prominent issue when any type of communication is being undertaken. Like traditional networks, supervisory control and data acquisition (SCADA) systems suffer from a number of vulnerabilities. Numerous end-to-end security mechanisms have been proposed for the resolution of SCADA-system security issues, but due to insecure real-time protocol use and the reliance upon open protocols during Internet-based communication, these SCADA systems can still be compromised by security challenges. This study reviews the security challenges and issues that are commonly raised during SCADA/protocol transmissions and proposes a secure distributed-network protocol version 3 (DNP3) design, and the implementation of the security solution using a cryptography mechanism. Due to the insecurities found within SCADA protocols, the new development consists of a DNP3 protocol that has been designed as a part of the SCADA system, and the cryptographically derived security is deployed within the application layer as a part of the DNP3 stack.
SCADA Protocol Anomaly Detection Utilizing Compression (SPADUC) 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon Rueff; Lyle Roybal; Denis Vollmer
2013-01-01
There is a significant need to protect the nation’s energy infrastructures from malicious actors using cyber methods. Supervisory, Control, and Data Acquisition (SCADA) systems may be vulnerable due to the insufficient security implemented during the design and deployment of these control systems. This is particularly true in older legacy SCADA systems that are still commonly in use. The purpose of INL’s research on the SCADA Protocol Anomaly Detection Utilizing Compression (SPADUC) project was to determine if and how data compression techniques could be used to identify and protect SCADA systems from cyber attacks. Initially, the concept was centered on howmore » to train a compression algorithm to recognize normal control system traffic versus hostile network traffic. Because large portions of the TCP/IP message traffic (called packets) are repetitive, the concept of using compression techniques to differentiate “non-normal” traffic was proposed. In this manner, malicious SCADA traffic could be identified at the packet level prior to completing its payload. Previous research has shown that SCADA network traffic has traits desirable for compression analysis. This work investigated three different approaches to identify malicious SCADA network traffic using compression techniques. The preliminary analyses and results presented herein are clearly able to differentiate normal from malicious network traffic at the packet level at a very high confidence level for the conditions tested. Additionally, the master dictionary approach used in this research appears to initially provide a meaningful way to categorize and compare packets within a communication channel.« less
SCADA OPERATOR TRAINING TOOL APPLIED TO THE CENTRAL ARIZONA IRRIGATION AND DRAINAGE DISTRICT
USDA-ARS?s Scientific Manuscript database
Many irrigation districts use Supervisory Control and Data Acquisition (SCADA) software to manage their canal systems. Whether homegrown or commercial, these programs require a significant amount of training for new operators. While some SCADA operators are hired with extensive field experience, o...
Wind turbine wake measurement in complex terrain
NASA Astrophysics Data System (ADS)
Hansen, KS; Larsen, GC; Menke, R.; Vasiljevic, N.; Angelou, N.; Feng, J.; Zhu, WJ; Vignaroli, A.; W, W. Liu; Xu, C.; Shen, WZ
2016-09-01
SCADA data from a wind farm and high frequency time series measurements obtained with remote scanning systems have been analysed with focus on identification of wind turbine wake properties in complex terrain. The analysis indicates that within the flow regime characterized by medium to large downstream distances (more than 5 diameters) from the wake generating turbine, the wake changes according to local atmospheric conditions e.g. vertical wind speed. In very complex terrain the wake effects are often “overruled” by distortion effects due to the terrain complexity or topology.
Attacks and intrusion detection in wireless sensor networks of industrial SCADA systems
NASA Astrophysics Data System (ADS)
Kamaev, V. A.; Finogeev, A. G.; Finogeev, A. A.; Parygin, D. S.
2017-01-01
The effectiveness of automated process control systems (APCS) and supervisory control and data acquisition systems (SCADA) information security depends on the applied protection technologies of transport environment data transmission components. This article investigates the problems of detecting attacks in wireless sensor networks (WSN) of SCADA systems. As a result of analytical studies, the authors developed the detailed classification of external attacks and intrusion detection in sensor networks and brought a detailed description of attacking impacts on components of SCADA systems in accordance with the selected directions of attacks.
Communication Security for Control Systems in Smart Grid
NASA Astrophysics Data System (ADS)
Robles, Rosslin John; Kim, Tai-Hoon
As an example of Control System, Supervisory Control and Data Acquisition systems can be relatively simple, such as one that monitors environmental conditions of a small office building, or incredibly complex, such as a system that monitors all the activity in a nuclear power plant or the activity of a municipal water system. SCADA systems are basically Process Control Systems, designed to automate systems such as traffic control, power grid management, waste processing etc. Connecting SCADA to the Internet can provide a lot of advantages in terms of control, data viewing and generation. SCADA infrastructures like electricity can also be a part of a Smart Grid. Connecting SCADA to a public network can bring a lot of security issues. To answer the security issues, a SCADA communication security solution is proposed.
Development of a novel SCADA system for laboratory testing.
Patel, M; Cole, G R; Pryor, T L; Wilmot, N A
2004-07-01
This document summarizes the supervisory control and data acquisition (SCADA) system that allows communication with, and controlling the output of, various I/O devices in the renewable energy systems and components test facility RESLab. This SCADA system differs from traditional SCADA systems in that it supports a continuously changing operating environment depending on the test to be performed. The SCADA System is based on the concept of having one Master I/O Server and multiple client computer systems. This paper describes the main features and advantages of this dynamic SCADA system, the connections of various field devices to the master I/O server, the device servers, and numerous software features used in the system. The system is based on the graphical programming language "LabVIEW" and its "Datalogging and Supervisory Control" (DSC) module. The DSC module supports a real-time database called the "tag engine," which performs the I/O operations with all field devices attached to the master I/O server and communications with the other tag engines running on the client computers connected via a local area network. Generic and detailed communication block diagrams illustrating the hierarchical structure of this SCADA system are presented. The flow diagram outlining a complete test performed using this system in one of its standard configurations is described.
Detecting Peer-to-Peer Botnets in SCADA Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Huan; Cheng, Liang; Chuah, Mooi Choo
Supervisory Control and Data Acquisition (SCADA) systems monitor and control critical infrastructure such as the smart grid. As SCADA systems become increasingly interconnected and adopt more and more cyber-enabled components, the risks of cyber attacks become a major concern. Due to their decentralized organization, peer-to-peer (P2P) botnets are resilient to many existing takedown measures and can be exploited as an effective way to launch cyber attacks on SCADA systems. However, little work has been done to detect P2P botnets in SCADA systems, which carry traffic flows with characteristics significantly different from the Internet. In this paper, we design a P2P-botnetmore » detection method for SCADA systems, leveraging built-in traffic monitoring capabilities of SCADA networking devices. The proposed method consists of two stages. In the first stage, we design a simple feature test to filter out non-P2P hosts, which significantly reduces the data volume for P2P-botnet identification. In the second stage, we jointly consider flow-based and connectivity-based features that effectively set apart bots from benign hosts. We propose to use unsupervised learning for P2P-botnet identification, which not only identifies known P2P botnets but also captures newly emerged ones. Our simulation results show that the proposed system achieves high detection rates with very few false positives. Furthermore, our evaluation shows that the proposed method can detect hosts running P2P SCADA applications that are infected by P2P bots.« less
Wake losses from averaged and time-resolved power measurements at full scale wind turbines
NASA Astrophysics Data System (ADS)
Castellani, Francesco; Astolfi, Davide; Mana, Matteo; Becchetti, Matteo; Segalini, Antonio
2017-05-01
This work deals with the experimental analysis of wake losses fluctuations at full-scale wind turbines. The test case is a wind farm sited on a moderately complex terrain: 4 turbines are installed, having 2 MW of rated power each. The sources of information are the time-resolved data, as collected from the OPC server, and the 10-minutes averaged SCADA data. The objective is to compare the statistical distributions of wake losses for far and middle wakes, as can be observed through the “fast” lens of time-resolved data, for certain selected test-case time series, and through the “slow” lens of SCADA data, on a much longer time basis that allow to set the standards of the mean wake losses along the wind farm. Further, time-resolved data are used for an insight into the spectral properties of wake fluctuations, highlighting the role of the wind turbine as low-pass filter. Summarizing, the wind rose, the layout of the site and the structure of the data sets at disposal allow to study middle and far wake behavior, with a “slow” and “fast” perspective.
Access Control Management for SCADA Systems
NASA Astrophysics Data System (ADS)
Hong, Seng-Phil; Ahn, Gail-Joon; Xu, Wenjuan
The information technology revolution has transformed all aspects of our society including critical infrastructures and led a significant shift from their old and disparate business models based on proprietary and legacy environments to more open and consolidated ones. Supervisory Control and Data Acquisition (SCADA) systems have been widely used not only for industrial processes but also for some experimental facilities. Due to the nature of open environments, managing SCADA systems should meet various security requirements since system administrators need to deal with a large number of entities and functions involved in critical infrastructures. In this paper, we identify necessary access control requirements in SCADA systems and articulate access control policies for the simulated SCADA systems. We also attempt to analyze and realize those requirements and policies in the context of role-based access control that is suitable for simplifying administrative tasks in large scale enterprises.
Using State Estimation Residuals to Detect Abnormal SCADA Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Jian; Chen, Yousu; Huang, Zhenyu
2010-06-14
Detection of manipulated supervisory control and data acquisition (SCADA) data is critically important for the safe and secure operation of modern power systems. In this paper, a methodology of detecting manipulated SCADA data based on state estimation residuals is presented. A framework of the proposed methodology is described. Instead of using original SCADA measurements as the bad data sources, the residuals calculated based on the results of the state estimator are used as the input for the outlier detection process. The BACON algorithm is applied to detect outliers in the state estimation residuals. The IEEE 118-bus system is used asmore » a test case to evaluate the effectiveness of the proposed methodology. The accuracy of the BACON method is compared with that of the 3-σ method for the simulated SCADA measurements and residuals.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barker, Alan M; Killough, Stephen M; Bigelow, Tim S
2011-01-01
Power Supply Controls are being developed at Oak Ridge National Laboratory (ORNL) to test transmission line components of the Electron Cyclotron Heating (ECH) system, with a focus on gyrotrons and waveguides, in support of the International Thermonuclear Experimental Reactor (ITER). The control is performed by several Programmable Logic Controllers (PLC s) located near the different equipment. A technique of Supervisory Control and Data Acquisition (SCADA) is presented to monitor, control, and log actions of the PLC s on a PC through use of Allen Bradley s Remote I/O communication interface coupled with an Open Process Control/Object Linking and Embedding [OLE]more » for Process Control (OPC) Server/Client architecture. The OPC data is then linked to a National Instruments (NI) LabVIEW system for monitoring and control. Details of the architecture and insight into applicability to other systems are presented in the rest of this paper. Future integration with an EPICS (Experimental Physics Industrial Control System) based mini-CODAC (Control, Data Access and Communication) SCADA system is under consideration, and integration considerations will be briefly introduced.« less
Review of Supervisory Control and Data Acquisition (SCADA) Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reva Nickelson; Briam Johnson; Ken Barnes
2004-01-01
A review using open source information was performed to obtain data related to Supervisory Control and Data Acquisition (SCADA) systems used to supervise and control domestic electric power generation, transmission, and distribution. This report provides the technical details for the types of systems used, system disposal, cyber and physical security measures, network connections, and a gap analysis of SCADA security holes.
Security Engineering and Educational Initiatives for Critical Information Infrastructures
2013-06-01
standard for cryptographic protection of SCADA communications. The United Kingdom’s National Infrastructure Security Co-ordination Centre (NISCC...has released a good practice guide on firewall deployment for SCADA systems and process control networks [17]. Meanwhile, National Institute for ...report. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED 18 The SCADA gateway collects the data gathered by sensors, translates them from
ERIC Educational Resources Information Center
Morsey, Christopher
2017-01-01
In the critical infrastructure world, many critical infrastructure sectors use a Supervisory Control and Data Acquisition (SCADA) system. The sectors that use SCADA systems are the electric power, nuclear power and water. These systems are used to control, monitor and extract data from the systems that give us all the ability to light our homes…
Susceptibility of SCADA systems and the energy sector
NASA Astrophysics Data System (ADS)
Goike, Lindsay
The research in this paper focused on analyzing SCADA systems in the energy sector for susceptibility to cyber attacks, in furtherance of providing suggestions to mitigate current and future cyber attacks. The research will be addressing the questions: how are SCADA systems susceptible to cyber attacks, and what are the suggested ways to mitigate both current and future cyber attacks. The five main categories of security vulnerabilities facing current SCADA systems were found to be: connectivity to the Internet, failure to plan, interdependency of sectors, numerous different types of threats, and outdated software. Some of the recommendations mentioned to mitigate current and future risks were: virtual private networks, risk assessments, increased physical security, updating of software, and firewalls.
Applying New Network Security Technologies to SCADA Systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurd, Steven A; Stamp, Jason Edwin; Duggan, David P
2006-11-01
Supervisory Control and Data Acquisition (SCADA) systems for automation are very important for critical infrastructure and manufacturing operations. They have been implemented to work in a number of physical environments using a variety of hardware, software, networking protocols, and communications technologies, often before security issues became of paramount concern. To offer solutions to security shortcomings in the short/medium term, this project was to identify technologies used to secure "traditional" IT networks and systems, and then assess their efficacy with respect to SCADA systems. These proposed solutions must be relatively simple to implement, reliable, and acceptable to SCADA owners and operators.more » 4This page intentionally left blank.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marco Carvalho; Richard Ford
2012-05-14
Supervisory Control and Data Acquisition (SCADA) Systems are a type of Industrial Control System characterized by the centralized (or hierarchical) monitoring and control of geographically dispersed assets. SCADA systems combine acquisition and network components to provide data gathering, transmission, and visualization for centralized monitoring and control. However these integrated capabilities, especially when built over legacy systems and protocols, generally result in vulnerabilities that can be exploited by attackers, with potentially disastrous consequences. Our research project proposal was to investigate new approaches for secure and survivable SCADA systems. In particular, we were interested in the resilience and adaptability of large-scale mission-criticalmore » monitoring and control infrastructures. Our research proposal was divided in two main tasks. The first task was centered on the design and investigation of algorithms for survivable SCADA systems and a prototype framework demonstration. The second task was centered on the characterization and demonstration of the proposed approach in illustrative scenarios (simulated or emulated).« less
Drainpipe network management information system design based on GIS and SCADA technique
NASA Astrophysics Data System (ADS)
Gu, Ze-Yu; Zhao, De-An
2011-02-01
Achieving urban drainpipe network integration of geographical information system (GIS) and supervisory control and data acquisition (SCADA) technology is described in this paper. The system design's plans are put forward, which have realized GIS and SCADA system supplementary in the technology and strengthened the model visible analysis ability. It is verified by practical cases that the system has more practical values and a good prospect.
Dynamic online sewer modelling in Helsingborg.
Hernebring, C; Jönsson, L E; Thorén, U B; Møller, A
2002-01-01
Within the last decade, the sewer system in Helsingborg, Sweden has been rehabilitated in many ways along with the reconstruction of the WWTP Oresundsverket in order to obtain a high degree of nitrogen and phosphorus removal. In that context a holistic view has been applied in order to optimise the corrective measures as seen from the effects in the receiving waters. A sewer catchment model has been used to evaluate several operation strategies and the effect of introducing RTC. Recently, a MOUSE ONLINE system was installed. In this phase the objective is to establish a stable communication with the SCADA system and to generate short-term flow forecasts.
NASA Astrophysics Data System (ADS)
Gu, Fei; Brouwer, Jack; Samuelsen, Scott
2013-09-01
Recent advances in inverter technology have enabled ancillary services such as volt/VAR regulation, SCADA communications, and active power filtering. Smart inverters can not only provide real power, but can be controlled to use excess capacity to provide reactive power compensation, power flow control, and active power filtering without supplementary inverter hardware. A transient level inverter model based on the Solectria 7700 inverter is developed and used to assess these control strategies using field data from an existing branch circuit containing two Amonix 68kW CPV-7700 systems installed at the University of California, Irvine.
Evaluation of Traditional Security Solutions in the SCADA Environment
2012-03-01
Evaluation of Traditional Security Solutions in the SCADA Environment THESIS Robert D. Larkin, Captain, USAF AFIT/GCO/ENG/12-06 DEPARTMENT OF THE AIR...views expressed in this thesis are those of the author and do not reflect the official policy or position of the United States Air Force, Department...United States. AFIT/GCO/ENG/12-06 Evaluation of Traditional Security Solutions in the SCADA Environment THESIS Presented to the Faculty Department of
2011-03-01
Byres, E. J., Lowe, J. (2004). The Myths and facts behind cyber security risks for industrial control systems . Berlin, Germany: VDE 2004 Congress...ACQUISITION (SCADA) SYSTEM THESIS Jason R. Nielsen, Major, USAF AFIT/GCO/ENG/11-10 DEPARTMENT OF THE AIR FORCE AIR UNIVERSITY AIR FORCE...DATA ACQUISITION (SCADA) SYSTEM THESIS Presented to the Faculty Department of Electrical and Computer Engineering Graduate School of
Enhancing the Safety, Security and Resilience of ICT and Scada Systems Using Action Research
NASA Astrophysics Data System (ADS)
Johnsen, Stig; Skramstad, Torbjorn; Hagen, Janne
This paper discusses the results of a questionnaire-based survey used to assess the safety, security and resilience of information and communications technology (ICT) and supervisory control and data acquisition (SCADA) systems used in the Norwegian oil and gas industry. The survey identifies several challenges, including the involvement of professionals with different backgrounds and expertise, lack of common risk perceptions, inadequate testing and integration of ICT and SCADA systems, poor information sharing related to undesirable incidents and lack of resilience in the design of technical systems. Action research is proposed as a process for addressing these challenges in a systematic manner and helping enhance the safety, security and resilience of ICT and SCADA systems used in oil and gas operations.
Design and installation of a next generation pilot scale fermentation system.
Junker, B; Brix, T; Lester, M; Kardos, P; Adamca, J; Lynch, J; Schmitt, J; Salmon, P
2003-01-01
Four new fermenters were designed and constructed for use in secondary metabolite cultivations, bioconversions, and enzyme production. A new PC/PLC-based control system also was implemented using GE Fanuc PLCs, Genius I/O blocks, and Fix Dynamics SCADA software. These systems were incorporated into an industrial research fermentation pilot plant, designed and constructed in the early 1980s. Details of the design of these new fermenters and the new control system are described and compared with the existing installation for expected effectiveness. In addition, the reasoning behind selection of some of these features has been included. Key to the design was the goal of preserving similarity between the new and previously existing and successfully utilized fermenter hardware and software installations where feasible but implementing improvements where warranted and beneficial. Examples of enhancements include strategic use of Inconel as a material of construction to reduce corrosion, piping layout design for simplified hazardous energy isolation, on-line calculation and control of nutrient feed rates, and the use of field I/O modules located near the vessel to permit low-cost addition of new instrumentation.
Earthquake Risk Reduction to Istanbul Natural Gas Distribution Network
NASA Astrophysics Data System (ADS)
Zulfikar, Can; Kariptas, Cagatay; Biyikoglu, Hikmet; Ozarpa, Cevat
2017-04-01
Earthquake Risk Reduction to Istanbul Natural Gas Distribution Network Istanbul Natural Gas Distribution Corporation (IGDAS) is one of the end users of the Istanbul Earthquake Early Warning (EEW) signal. IGDAS, the primary natural gas provider in Istanbul, operates an extensive system 9,867km of gas lines with 750 district regulators and 474,000 service boxes. The natural gas comes to Istanbul city borders with 70bar in 30inch diameter steel pipeline. The gas pressure is reduced to 20bar in RMS stations and distributed to district regulators inside the city. 110 of 750 district regulators are instrumented with strong motion accelerometers in order to cut gas flow during an earthquake event in the case of ground motion parameters exceeds the certain threshold levels. Also, state of-the-art protection systems automatically cut natural gas flow when breaks in the gas pipelines are detected. IGDAS uses a sophisticated SCADA (supervisory control and data acquisition) system to monitor the state-of-health of its pipeline network. This system provides real-time information about quantities related to pipeline monitoring, including input-output pressure, drawing information, positions of station and RTU (remote terminal unit) gates, slum shut mechanism status at 750 district regulator sites. IGDAS Real-time Earthquake Risk Reduction algorithm follows 4 stages as below: 1) Real-time ground motion data transmitted from 110 IGDAS and 110 KOERI (Kandilli Observatory and Earthquake Research Institute) acceleration stations to the IGDAS Scada Center and KOERI data center. 2) During an earthquake event EEW information is sent from IGDAS Scada Center to the IGDAS stations. 3) Automatic Shut-Off is applied at IGDAS district regulators, and calculated parameters are sent from stations to the IGDAS Scada Center and KOERI. 4) Integrated building and gas pipeline damage maps are prepared immediately after the earthquake event. The today's technology allows to rapidly estimate the expected level of shaking when an earthquake starts to occur. However, in Istanbul case for a potential Marmara Sea Earthquake, the time is very limited even to estimate the level of shaking. The robust threshold based EEW system is only algorithm for such a near source event to activate automatic shut-off mechanism in the critical infrastructures before the damaging waves arrive. This safety measure even with a few seconds of early warning time will help to mitigate potential damages and secondary hazards.
7 CFR 1726.176 - Communications and control facilities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... line carrier communications systems, load control, and supervisory control and data acquisition (SCADA...) Load control systems, communications systems, and SCADA systems—(1) Contract forms. The borrower must...
7 CFR 1726.176 - Communications and control facilities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... line carrier communications systems, load control, and supervisory control and data acquisition (SCADA...) Load control systems, communications systems, and SCADA systems—(1) Contract forms. The borrower must...
7 CFR 1726.176 - Communications and control facilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... line carrier communications systems, load control, and supervisory control and data acquisition (SCADA...) Load control systems, communications systems, and SCADA systems—(1) Contract forms. The borrower must...
7 CFR 1726.176 - Communications and control facilities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... line carrier communications systems, load control, and supervisory control and data acquisition (SCADA...) Load control systems, communications systems, and SCADA systems—(1) Contract forms. The borrower must...
Design of virtual SCADA simulation system for pressurized water reactor
NASA Astrophysics Data System (ADS)
Wijaksono, Umar; Abdullah, Ade Gafar; Hakim, Dadang Lukman
2016-02-01
The Virtual SCADA system is a software-based Human-Machine Interface that can visualize the process of a plant. This paper described the results of the virtual SCADA system design that aims to recognize the principle of the Nuclear Power Plant type Pressurized Water Reactor. This simulation uses technical data of the Nuclear Power Plant Unit Olkiluoto 3 in Finland. This device was developed using Wonderware Intouch, which is equipped with manual books for each component, animation links, alarm systems, real time and historical trending, and security system. The results showed that in general this device can demonstrate clearly the principles of energy flow and energy conversion processes in Pressurized Water Reactors. This virtual SCADA simulation system can be used as instructional media to recognize the principle of Pressurized Water Reactor.
Using Physical Models for Anomaly Detection in Control Systems
NASA Astrophysics Data System (ADS)
Svendsen, Nils; Wolthusen, Stephen
Supervisory control and data acquisition (SCADA) systems are increasingly used to operate critical infrastructure assets. However, the inclusion of advanced information technology and communications components and elaborate control strategies in SCADA systems increase the threat surface for external and subversion-type attacks. The problems are exacerbated by site-specific properties of SCADA environments that make subversion detection impractical; and by sensor noise and feedback characteristics that degrade conventional anomaly detection systems. Moreover, potential attack mechanisms are ill-defined and may include both physical and logical aspects.
Analysis of a SCADA System Anomaly Detection Model Based on Information Entropy
2014-03-27
20 Intrusion Detection...alarms ( Rem ). ............................................................................................................. 86 Figure 25. TP% for...literature concerning the focus areas of this research. The focus areas include SCADA vulnerabilities, information theory, and intrusion detection
Design of virtual SCADA simulation system for pressurized water reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wijaksono, Umar, E-mail: umar.wijaksono@student.upi.edu; Abdullah, Ade Gafar; Hakim, Dadang Lukman
The Virtual SCADA system is a software-based Human-Machine Interface that can visualize the process of a plant. This paper described the results of the virtual SCADA system design that aims to recognize the principle of the Nuclear Power Plant type Pressurized Water Reactor. This simulation uses technical data of the Nuclear Power Plant Unit Olkiluoto 3 in Finland. This device was developed using Wonderware Intouch, which is equipped with manual books for each component, animation links, alarm systems, real time and historical trending, and security system. The results showed that in general this device can demonstrate clearly the principles ofmore » energy flow and energy conversion processes in Pressurized Water Reactors. This virtual SCADA simulation system can be used as instructional media to recognize the principle of Pressurized Water Reactor.« less
On the use of high-frequency SCADA data for improved wind turbine performance monitoring
NASA Astrophysics Data System (ADS)
Gonzalez, E.; Stephen, B.; Infield, D.; Melero, J. J.
2017-11-01
SCADA-based condition monitoring of wind turbines facilitates the move from costly corrective repairs towards more proactive maintenance strategies. In this work, we advocate the use of high-frequency SCADA data and quantile regression to build a cost effective performance monitoring tool. The benefits of the approach are demonstrated through the comparison between state-of-the-art deterministic power curve modelling techniques and the suggested probabilistic model. Detection capabilities are compared for low and high-frequency SCADA data, providing evidence for monitoring at higher resolutions. Operational data from healthy and faulty turbines are used to provide a practical example of usage with the proposed tool, effectively achieving the detection of an incipient gearbox malfunction at a time horizon of more than one month prior to the actual occurrence of the failure.
Production Facility SCADA Design Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dale, Gregory E.; Holloway, Michael Andrew; Baily, Scott A.
2015-03-23
The following report covers FY 14 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production facility. The goal of this effort is to provide Northstar with a baseline system design.
Real-Time Monitoring of Scada Based Control System for Filling Process
NASA Astrophysics Data System (ADS)
Soe, Aung Kyaw; Myint, Aung Naing; Latt, Maung Maung; Theingi
2008-10-01
This paper is a design of real-time monitoring for filling system using Supervisory Control and Data Acquisition (SCADA). The monitoring of production process is described in real-time using Visual Basic.Net programming under Visual Studio 2005 software without SCADA software. The software integrators are programmed to get the required information for the configuration screens. Simulation of components is expressed on the computer screen using parallel port between computers and filling devices. The programs of real-time simulation for the filling process from the pure drinking water industry are provided.
State-Based Network Intrusion Detection Systems for SCADA Protocols: A Proof of Concept
NASA Astrophysics Data System (ADS)
Carcano, Andrea; Fovino, Igor Nai; Masera, Marcelo; Trombetta, Alberto
We present a novel Intrusion Detection System able to detect complex attacks to SCADA systems. By complex attack, we mean a set of commands (carried in Modbus packets) that, while licit when considered in isolation on a single-packet basis, interfere with the correct behavior of the system. The proposed IDS detects such attacks thanks to an internal representation of the controlled SCADA system and a corresponding rule language, powerful enough to express the system's critical states. Furthermore, we detail the implementation and provide experimental comparative results.
Design and Implementation of a Secure Modbus Protocol
NASA Astrophysics Data System (ADS)
Fovino, Igor Nai; Carcano, Andrea; Masera, Marcelo; Trombetta, Alberto
The interconnectivity of modern and legacy supervisory control and data acquisition (SCADA) systems with corporate networks and the Internet has significantly increased the threats to critical infrastructure assets. Meanwhile, traditional IT security solutions such as firewalls, intrusion detection systems and antivirus software are relatively ineffective against attacks that specifically target vulnerabilities in SCADA protocols. This paper describes a secure version of the Modbus SCADA protocol that incorporates integrity, authentication, non-repudiation and anti-replay mechanisms. Experimental results using a power plant testbed indicate that the augmented protocol provides good security functionality without significant overhead.
Designing a SCADA system simulator for fast breeder reactor
NASA Astrophysics Data System (ADS)
Nugraha, E.; Abdullah, A. G.; Hakim, D. L.
2016-04-01
SCADA (Supervisory Control and Data Acquisition) system simulator is a Human Machine Interface-based software that is able to visualize the process of a plant. This study describes the results of the process of designing a SCADA system simulator that aims to facilitate the operator in monitoring, controlling, handling the alarm, accessing historical data and historical trend in Nuclear Power Plant (NPP) type Fast Breeder Reactor (FBR). This research used simulation to simulate NPP type FBR Kalpakkam in India. This simulator was developed using Wonderware Intouch software 10 and is equipped with main menu, plant overview, area graphics, control display, set point display, alarm system, real-time trending, historical trending and security system. This simulator can properly simulate the principle of energy flow and energy conversion process on NPP type FBR. This SCADA system simulator can be used as training media for NPP type FBR prospective operators.
Analysis of Bright Harvest Remote Analysis for Residential Solar Installations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nangle, John; Simon, Joseph
Bright Harvest provides remote shading analysis and design products for residential PV system installers. The National Renewable Energy Laboratory (NREL) through the NREL Commercialization Assistance Program, completed comparative assessments between on-site measurements and remotely calculated values to validate the accuracy of Bright Harvest’s remote shading and power generation.
Detector Control System for the AFP detector in ATLAS experiment at CERN
NASA Astrophysics Data System (ADS)
Banaś, E.; Caforio, D.; Czekierda, S.; Hajduk, Z.; Olszowska, J.; Seabra, L.; Šícho, P.
2017-10-01
The ATLAS Forward Proton (AFP) detector consists of two forward detectors located at 205 m and 217 m on either side of the ATLAS experiment. The aim is to measure the momenta and angles of diffractively scattered protons. In 2016, two detector stations on one side of the ATLAS interaction point were installed and commissioned. The detector infrastructure and necessary services were installed and are supervised by the Detector Control System (DCS), which is responsible for the coherent and safe operation of the detector. A large variety of used equipment represents a considerable challenge for the AFP DCS design. Industrial Supervisory Control and Data Acquisition (SCADA) product Siemens WinCCOA, together with the CERN Joint Control Project (JCOP) framework and standard industrial and custom developed server applications and protocols are used for reading, processing, monitoring and archiving of the detector parameters. Graphical user interfaces allow for overall detector operation and visualization of the detector status. Parameters, important for the detector safety, are used for alert generation and interlock mechanisms.
Industrial Control Systems/SCADA systems risk assessment in the energy sector
NASA Astrophysics Data System (ADS)
Falodun, Babatunde
The energy sector is one of the most critical components of our national infrastructure. It not only provides the electrical power and petroleum required to run day-to-day operations and mechanisms in society, it's also an important element that directly impacts the economy with regard to growth and stability. Industrial Control Systems (ICS) /Supervisory Control and Data Acquisition Systems (SCADA) are computerized mechanisms, they are both software and hardware that are used to control real time processes and operations in power plants and oil production facilities. A significant attack on these control systems that leads to widespread disruption of energy could result in catastrophic consequences for any major city and even the nation. This research paper explores cyber threats and vulnerabilities faced by ICS/SCADA systems in the energy sector and also highlights possible outcomes of a successful breach. Furthermore, the research underscores mitigation strategies that could be used to prevent and respond to an attack. Keywords: Cybersecurity, SCADA, Cyber Attacks, Threats, Vulnerabilities, Risk Assessment, Dr. Albert Orbinati.
Evaluating resilience of DNP3-controlled SCADA systems against event buffer flooding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Guanhua; Nicol, David M; Jin, Dong
2010-12-16
The DNP3 protocol is widely used in SCADA systems (particularly electrical power) as a means of communicating observed sensor state information back to a control center. Typical architectures using DNP3 have a two level hierarchy, where a specialized data aggregator device receives observed state from devices within a local region, and the control center collects the aggregated state from the data aggregator. The DNP3 communication between control center and data aggregator is asynchronous with the DNP3 communication between data aggregator and relays; this leads to the possibility of completely filling a data aggregator's buffer of pending events, when a relaymore » is compromised or spoofed and sends overly many (false) events to the data aggregator. This paper investigates how a real-world SCADA device responds to event buffer flooding. A Discrete-Time Markov Chain (DTMC) model is developed for understanding this. The DTMC model is validated by a Moebius simulation model and data collected on real SCADA testbed.« less
NASA Astrophysics Data System (ADS)
Topolskiy, D.; Topolskiy, N.; Solomin, E.; Topolskaya, I.
2016-04-01
In the present paper the authors discuss some ways of solving energy saving problems in mechanical engineering. In authors' opinion one of the ways of solving this problem is integrated modernization of power engineering objects of mechanical engineering companies, which should be intended for the energy supply control efficiency increase and electric energy commercial accounting improvement. The author have proposed the usage of digital current and voltage transformers for these purposes. To check the compliance of this equipment with the IEC 61850 International Standard, we have built a mathematic model of the data exchange process between measuring transformers and a universal SCADA-system. The results of modeling show that the discussed equipment corresponds to the mentioned Standard requirements and the usage of the universal SCADA-system for these purposes is preferable and economically reasonable. In modeling the authors have used the following software: MasterScada, Master OPC_DI_61850, OPNET.
Providing Situational Awareness for Pipeline Control Operations
NASA Astrophysics Data System (ADS)
Butts, Jonathan; Kleinhans, Hugo; Chandia, Rodrigo; Papa, Mauricio; Shenoi, Sujeet
A SCADA system for a single 3,000-mile-long strand of oil or gas pipeline may employ several thousand field devices to measure process parameters and operate equipment. Because of the vital tasks performed by these sensors and actuators, pipeline operators need accurate and timely information about their status and integrity. This paper describes a realtime scanner that provides situational awareness about SCADA devices and control operations. The scanner, with the assistance of lightweight, distributed sensors, analyzes SCADA network traffic, verifies the operational status and integrity of field devices, and identifies anomalous activity. Experimental results obtained using real pipeline control traffic demonstrate the utility of the scanner in industrial settings.
NASA Astrophysics Data System (ADS)
Leahy, Kevin; Gallagher, Colm; Bruton, Ken; O'Donovan, Peter; O'Sullivan, Dominic T. J.
2017-11-01
Using 10-minute wind turbine SCADA data for fault prediction offers an attractive way of gaining additional prognostic capabilities without needing to invest in extra hardware. To use these data-driven methods effectively, the historical SCADA data must be labelled with the periods when the turbine was in faulty operation as well the sub-system the fault was attributed to. Manually identifying faults using maintenance logs can be effective, but is also highly time consuming and tedious due to the disparate nature of these logs across manufacturers, operators and even individual maintenance events. Turbine alarm systems can help to identify these periods, but the sheer volume of alarms and false positives generated makes analysing them on an individual basis ineffective. In this work, we present a new method for automatically identifying historical stoppages on the turbine using SCADA and alarms data. Each stoppage is associated with either a fault in one of the turbine’s sub-systems, a routine maintenance activity, a grid-related event or a number of other categories. This is then checked against maintenance logs for accuracy and the labelled data fed into a classifier for predicting when these stoppages will occur. Results show that the automated labelling process correctly identifies each type of stoppage, and can be effectively used for SCADA-based prediction of turbine faults.
Superstorm Sandy: Implications For Designing A PostCyber Attack Power Restoration System
2016-03-31
for such progress. Phillip Allison, “ Cloak and Secure Your Critical Infrastructure, ICS and SCADA Systems: Building Security into Your Industrial...TechSvcs/Multi-stateFleetResponseWorkshopReport-02-21-13.pdf. Allison, Phillip. “ Cloak and Secure Your Critical Infrastructure, ICS and SCADA Systems
Supervisory Control and Data Acquisition System | Energy Systems
Integration Facility | NREL Supervisory Control and Data Acquisition System Supervisory Control supervisory control and data acquisition (SCADA) system monitors and controls safety systems and gathers real Energy Systems Integration Facility control room. The Energy Systems Integration Facility's SCADA system
Scada Malware, a Proof of Concept
NASA Astrophysics Data System (ADS)
Carcano, Andrea; Fovino, Igor Nai; Masera, Marcelo; Trombetta, Alberto
Critical Infrastructures are nowadays exposed to new kind of threats. The cause of such threats is related to the large number of new vulnerabilities and architectural weaknesses introduced by the extensive use of ICT and Network technologies into such complex critical systems. Of particular interest are the set of vulnerabilities related to the class of communication protocols normally known as “SCADA” protocols, under which fall all the communication protocols used to remotely control the RTU devices of an industrial system. In this paper we present a proof of concept of the potential effects of a set of computer malware specifically designed and created in order to impact, by taking advantage of some vulnerabilities of the ModBUS protocol, on a typical Supervisory Control and Data Acquisition system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jared Verba; Michael Milvich
2008-05-01
Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting maliciousmore » activity.« less
Zhao, Junbo; Wang, Shaobu; Mili, Lamine; ...
2018-01-08
Here, this paper develops a robust power system state estimation framework with the consideration of measurement correlations and imperfect synchronization. In the framework, correlations of SCADA and Phasor Measurements (PMUs) are calculated separately through unscented transformation and a Vector Auto-Regression (VAR) model. In particular, PMU measurements during the waiting period of two SCADA measurement scans are buffered to develop the VAR model with robustly estimated parameters using projection statistics approach. The latter takes into account the temporal and spatial correlations of PMU measurements and provides redundant measurements to suppress bad data and mitigate imperfect synchronization. In case where the SCADAmore » and PMU measurements are not time synchronized, either the forecasted PMU measurements or the prior SCADA measurements from the last estimation run are leveraged to restore system observability. Then, a robust generalized maximum-likelihood (GM)-estimator is extended to integrate measurement error correlations and to handle the outliers in the SCADA and PMU measurements. Simulation results that stem from a comprehensive comparison with other alternatives under various conditions demonstrate the benefits of the proposed framework.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Junbo; Wang, Shaobu; Mili, Lamine
Here, this paper develops a robust power system state estimation framework with the consideration of measurement correlations and imperfect synchronization. In the framework, correlations of SCADA and Phasor Measurements (PMUs) are calculated separately through unscented transformation and a Vector Auto-Regression (VAR) model. In particular, PMU measurements during the waiting period of two SCADA measurement scans are buffered to develop the VAR model with robustly estimated parameters using projection statistics approach. The latter takes into account the temporal and spatial correlations of PMU measurements and provides redundant measurements to suppress bad data and mitigate imperfect synchronization. In case where the SCADAmore » and PMU measurements are not time synchronized, either the forecasted PMU measurements or the prior SCADA measurements from the last estimation run are leveraged to restore system observability. Then, a robust generalized maximum-likelihood (GM)-estimator is extended to integrate measurement error correlations and to handle the outliers in the SCADA and PMU measurements. Simulation results that stem from a comprehensive comparison with other alternatives under various conditions demonstrate the benefits of the proposed framework.« less
Wang, Hao; Lau, Nathan; Gerdes, Ryan M
2018-04-01
The aim of this study was to apply work domain analysis for cybersecurity assessment and design of supervisory control and data acquisition (SCADA) systems. Adoption of information and communication technology in cyberphysical systems (CPSs) for critical infrastructures enables automated and distributed control but introduces cybersecurity risk. Many CPSs employ SCADA industrial control systems that have become the target of cyberattacks, which inflict physical damage without use of force. Given that absolute security is not feasible for complex systems, cyberintrusions that introduce unanticipated events will occur; a proper response will in turn require human adaptive ability. Therefore, analysis techniques that can support security assessment and human factors engineering are invaluable for defending CPSs. We conducted work domain analysis using the abstraction hierarchy (AH) to model a generic SCADA implementation to identify the functional structures and means-ends relations. We then adopted a case study approach examining the Stuxnet cyberattack by developing and integrating AHs for the uranium enrichment process, SCADA implementation, and malware to investigate the interactions between the three aspects of cybersecurity in CPSs. The AHs for modeling a generic SCADA implementation and studying the Stuxnet cyberattack are useful for mapping attack vectors, identifying deficiencies in security processes and features, and evaluating proposed security solutions with respect to system objectives. Work domain analysis is an effective analytical method for studying cybersecurity of CPSs for critical infrastructures in a psychologically relevant manner. Work domain analysis should be applied to assess cybersecurity risk and inform engineering and user interface design.
DEVELOPMENT OF REMOTE HANFORD CONNECTOR GASKET REPLACEMENT TOOLING FOR DWPF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krementz, D.; Coughlin, Jeffrey
2009-05-05
The Defense Waste Processing Facility (DWPF) requested the Savannah River National Laboratory (SRNL) to develop tooling and equipment to remotely replace gaskets in mechanical Hanford connectors to reduce personnel radiation exposure as compared to the current hands-on method. It is also expected that radiation levels will continually increase with future waste streams. The equipment is operated in the Remote Equipment Decontamination Cell (REDC), which is equipped with compressed air, two master-slave manipulators (MSM's) and an electro-mechanical manipulator (EMM) arm for operation of the remote tools. The REDC does not provide access to electrical power, so the equipment must be manuallymore » or pneumatically operated. The MSM's have a load limit at full extension of ten pounds, which limited the weight of the installation tool. In order to remotely replace Hanford connector gaskets several operations must be performed remotely, these include: removal of the spent gasket and retaining ring (retaining ring is also called snap ring), loading the new snap ring and gasket into the installation tool and installation of the new gasket into the Hanford connector. SRNL developed and tested tools that successfully perform all of the necessary tasks. Removal of snap rings from horizontal and vertical connectors is performed by separate air actuated retaining ring removal tools and is manipulated in the cell by the MSM. In order install a new gasket, the snap ring loader is used to load a new snap ring into a groove in the gasket installation tool. A new gasket is placed on the installation tool and retained by custom springs. An MSM lifts the installation tool and presses the mounted gasket against the connector block. Once the installation tool is in position, the gasket and snap ring are installed onto the connector by pneumatic actuation. All of the tools are located on a custom work table with a pneumatic valve station that directs compressed air to the desired tool and vents the tools as needed. Extensive testing of tooling operation was performed in the DWPF manipulator repair shop. This testing allowed the operators to gain confidence before the equipment was exposed to radioactive contamination. The testing also led to multiple design improvements. On July 17 and 29, 2008 the Remote Gasket Replacement Tooling was successfully demonstrated in the REDC at the DWPF of The Savannah River Site.« less
2010-03-01
CODIFYING INFORMATION ASSURANCE CONTROLS FOR DEPARTMENT OF DEFENSE (DOD) SUPERVISORY CONTROL AND DATA...Force, Department of Defense, or the U.S. Government. AFIT/GCO/ENG/10-13 CODIFYING INFORMATION ASSURANCE CONTROLS FOR DEPARTMENT OF...DEFENSE (DOD) SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) SYSTEMS THESIS Presented to the Faculty Department of Electrical and Computer
Expanding Combat Power Through Military Cyberpower Theory
2015-04-02
systems (ICS) and supervisory control and data acquisition systems ( SCADA ) are public-facing, providing more avenues of approach for an adversary. ICS...and SCADA are the two primary means for cyber adversaries to achieve direct physical effects through cyberspace. Strategic Attribution. From a...REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to
The Commanding Officer’s Perspective on Protecting Shipboard IT Networks
2014-09-01
potential checklist for protecting Supervisory Control and Data Acquisition ( SCADA ) systems. “A SCADA system is the software that controls networks such as...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited THE COMMANDING... for this collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data
Cyber security risk assessment for SCADA and DCS networks.
Ralston, P A S; Graham, J H; Hieb, J L
2007-10-01
The growing dependence of critical infrastructures and industrial automation on interconnected physical and cyber-based control systems has resulted in a growing and previously unforeseen cyber security threat to supervisory control and data acquisition (SCADA) and distributed control systems (DCSs). It is critical that engineers and managers understand these issues and know how to locate the information they need. This paper provides a broad overview of cyber security and risk assessment for SCADA and DCS, introduces the main industry organizations and government groups working in this area, and gives a comprehensive review of the literature to date. Major concepts related to the risk assessment methods are introduced with references cited for more detail. Included are risk assessment methods such as HHM, IIM, and RFRM which have been applied successfully to SCADA systems with many interdependencies and have highlighted the need for quantifiable metrics. Presented in broad terms is probability risk analysis (PRA) which includes methods such as FTA, ETA, and FEMA. The paper concludes with a general discussion of two recent methods (one based on compromise graphs and one on augmented vulnerability trees) that quantitatively determine the probability of an attack, the impact of the attack, and the reduction in risk associated with a particular countermeasure.
Changing the Lines in the Coloring Book
2004-05-18
multitude of SCADA programmers creates a multitude of idiosyncratic programs, making it very difficult to know how to hack into large numbers of them...an observed pattern of hacking that would alert authorities seems not to have been discussed.) However, some SCADAs are not physically connected to the...normal hacking . Simultaneously, it would identify software vulnerabilities in other products and design viruses and worms for attacking them. (The
Secure SCADA communication by using a modified key management scheme.
Rezai, Abdalhossein; Keshavarzi, Parviz; Moravej, Zahra
2013-07-01
This paper presents and evaluates a new cryptographic key management scheme which increases the efficiency and security of the Supervisory Control And Data Acquisition (SCADA) communication. In the proposed key management scheme, two key update phases are used: session key update and master key update. In the session key update phase, session keys are generated in the master station. In the master key update phase, the Elliptic Curve Diffie-Hellman (ECDH) protocol is used. The Poisson process is also used to model the Security Index (SI) and Quality of Service (QoS). Our analysis shows that the proposed key management not only supports the required speed in the MODBUS implementation but also has several advantages compared to other key management schemes for secure communication in SCADA networks. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
Brazil upgrades microwave system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Newman, H.S.; Gomes, H.P.
1979-02-01
To provide communications facilities necessary during major construction projects, and for the operation and control of the expanding electric-power network, in 1967 Furnas-Centrais Eletricas SA, Brazil, started installing the first 22 links of its microwave system, from the Botafogo plant in Rio de Janeiro to the Furnas hydro station, and from the Furnas hydro station, southwest, to the Guarulhos plant in Sao Paulo and northwest to the Estreito hydro plant. To accommodate the construction of additional hydroelectric facilities, the second and third microwave-system expansions added nine links from Estreito hydro, northwest, to Marimbondo hydro and 7 links to Itumbiara. Themore » fourth expansion included two links to connect with the Angra dos Reis nuclear generating plant. A modern SCADA system replaced an earlier fault-reporting method, and a means of monitoring performance communications was established.« less
Resilient Control and Intrusion Detection for SCADA Systems
2014-05-01
Control. McGraw-Hill, 1996. [89] L. Greenemeier. Robots arrive at fukushima nuclear site with unclear mission. Scientific American, 2011. [90] M. Grimes...security engineering task. SCADA systems are hard real-time systems [251] because the completion of an operation after its deadline is considered useless and...that the attacker, after gaining unauthenticated access, could change the operator display values so that when an alarm actually goes off, the human
Critical Infrastructure: Control Systems and the Terrorist Threat
2004-01-20
Congressional Research Service ˜ The Library of Congress CRS Report for Congress Received through the CRS Web Order Code RL31534 Critical...http://www.pnl.gov/main/sectors/homeland.html]. 68 Rolf Carlson, “Sandia SCADA Program High-Security SCADA LDRD Final Report ,” Sandia Report SAND2002...and Industry Division Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to
Critical Infrastructure: Control Systems and the Terrorist Threat
2003-07-14
Congressional Research Service ˜ The Library of Congress CRS Report for Congress Received through the CRS Web Order Code RL31534 Critical...available online at [http://www.pnl.gov/main/sectors/homeland.html]. 56 Rolf Carlson, “Sandia SCADA Program High-Security SCADA LDRD Final Report ...Industry Division Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to
Multiple Flow Loop SCADA System Implemented on the Production Prototype Loop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baily, Scott A.; Dalmas, Dale Allen; Wheat, Robert Mitchell
2015-11-16
The following report covers FY 15 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production prototype gas flow loop. The goal of this effort is to expand the existing system to include a second flow loop with a larger production-sized blower. Besides testing the larger blower, this system will demonstrate the scalability of our solution to multiple flow loops.
SCADA Application for ACTS Technology
NASA Technical Reports Server (NTRS)
Fairbanks, Barry
1992-01-01
The results of a system level study done by Hughes Network Systems for NASA are presented. For the supervisory control and data acquisition (SCADA) application, use of Ka-band spot beam satellite technology associated with NASA's Advanced Communication Technology Satellite (ACTS) offers a reduction in Earth station antenna size and transmitter power that may translate into lower system costs. The approaches taken to determine commercial potential of the system are described.
SCADA data and the quantification of hazardous events for QMRA.
Nilsson, P; Roser, D; Thorwaldsdotter, R; Petterson, S; Davies, C; Signor, R; Bergstedt, O; Ashbolt, N
2007-01-01
The objective of this study was to assess the use of on-line monitoring to support the QMRA at water treatment plants studied in the EU MicroRisk project. SCADA data were obtained from three Catchment-to-Tap Systems (CTS) along with system descriptions, diary records, grab sample data and deviation reports. Particular attention was paid to estimating hazardous event frequency, duration and magnitude. Using Shewart and CUSUM we identified 'change-points' corresponding to events of between 10 min and >1 month duration in timeseries data. Our analysis confirmed it is possible to quantify hazardous event durations from turbidity, chlorine residual and pH records and distinguish them from non-hazardous variability in the timeseries dataset. The durations of most 'events' were short-term (0.5-2.3 h). These data were combined with QMRA to estimate pathogen infection risk arising from such events as chlorination failure. While analysis of SCADA data alone could identify events provisionally, its interpretation was severely constrained in the absence of diary records and other system information. SCADA data analysis should only complement traditional water sampling, rather than replace it. More work on on-line data management, quality control and interpretation is needed before it can be used routinely for event characterization.
Smith, P J; Vigneswaran, S; Ngo, H H; Nguyen, H T; Ben-Aim, R
2006-01-01
The application of automation and supervisory control and data acquisition (SCADA) systems to municipal water and wastewater treatment plants is rapidly increasing. However, the application of these systems is less frequent in the research and development phases of emerging treatment technologies used in these industries. This study involved the implementation of automation and a SCADA system to the submerged membrane adsorption hybrid system for use in a semi-pilot scale research project. An incremental approach was used in the development of the automation and SCADA systems, leading to the development of two new control systems. The first system developed involved closed loop control of the backwash initiation, based upon a pressure increase, leading to productivity improvements as the backwash is only activated when required, not at a fixed time. This system resulted in a 40% reduction in the number of backwashes required and also enabled optimised operations under unsteady concentrations of wastewater. The second system developed involved closed loop control of the backwash duration, whereby the backwash was terminated when the pressure reached a steady state. This system resulted in a reduction of the duration of the backwash of up to 25% and enabled optimised operations as the foulant build-up within the reactor increased.
Development of an automatic subsea blowout preventer stack control system using PLC based SCADA.
Cai, Baoping; Liu, Yonghong; Liu, Zengkai; Wang, Fei; Tian, Xiaojie; Zhang, Yanzhen
2012-01-01
An extremely reliable remote control system for subsea blowout preventer stack is developed based on the off-the-shelf triple modular redundancy system. To meet a high reliability requirement, various redundancy techniques such as controller redundancy, bus redundancy and network redundancy are used to design the system hardware architecture. The control logic, human-machine interface graphical design and redundant databases are developed by using the off-the-shelf software. A series of experiments were performed in laboratory to test the subsea blowout preventer stack control system. The results showed that the tested subsea blowout preventer functions could be executed successfully. For the faults of programmable logic controllers, discrete input groups and analog input groups, the control system could give correct alarms in the human-machine interface. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
Programmable Logic Controller Modification Attacks for use in Detection Analysis
2014-03-27
and J. Lowe, “The Myths and Facts Behind Cyber Security Risks for Industrial Control Systems ,” in Proceedings of the VDE Kongress, vol. 116, 2004. [13...Feb 2014 Date 20 Feb 2014 Date 20 Feb 2014 Date AFIT-ENG-14-M-66 Abstract Unprotected Supervisory Control and Data Acquisition (SCADA) systems offer...control and monitor physical industrial processes. Although attacks targeting SCADA systems have increased, there has been little work exploring the
NASA Astrophysics Data System (ADS)
Robertson, Jamie; Shinozuka, Masanobu; Wu, Felix
2011-04-01
When a lifeline system such as a water delivery network is damaged due to a severe earthquake, it is critical to identify its location and extent of the damage in real time in order to minimize the potentially disastrous consequence such damage could otherwise entail. This paper demonstrates how the degree of such minimization can be estimated qualitatively by using the water delivery system of Irvine Water Ranch District (IRWD) as testbed, when it is subjected to magnitude 6.6 San Joaquin Hills Earthquake. In this demonstration, we consider two cases when the IRWD system is equipped or not equipped with a next generation SCADA which consists of a network of MEMS acceleration sensors densely populated and optimally located. These sensors are capable of identifying the location and extent of the damage as well as transmitting the data to the SCADA center for monitoring and control.
SCADA alarms processing for wind turbine component failure detection
NASA Astrophysics Data System (ADS)
Gonzalez, E.; Reder, M.; Melero, J. J.
2016-09-01
Wind turbine failure and downtime can often compromise the profitability of a wind farm due to their high impact on the operation and maintenance (O&M) costs. Early detection of failures can facilitate the changeover from corrective maintenance towards a predictive approach. This paper presents a cost-effective methodology to combine various alarm analysis techniques, using data from the Supervisory Control and Data Acquisition (SCADA) system, in order to detect component failures. The approach categorises the alarms according to a reviewed taxonomy, turning overwhelming data into valuable information to assess component status. Then, different alarms analysis techniques are applied for two purposes: the evaluation of the SCADA alarm system capability to detect failures, and the investigation of the relation between components faults being followed by failure occurrences in others. Various case studies are presented and discussed. The study highlights the relationship between faulty behaviour in different components and between failures and adverse environmental conditions.
49 CFR 178.338-11 - Discharge control devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... water capacity, remote means of automatic closure must be installed at the ends of the cargo tank in at... control system. (ii) On a cargo tank motor vehicle of 3,500 gallons water capacity or less, at least one remote means of automatic closure must be installed on the end of the cargo tank farthest away from the...
A Survey of Research in Supervisory Control and Data Acquisition (SCADA)
2014-09-01
distance learning .2 The data acquired may be operationally oriented and used to better run the system, or it could be strategic in nature and used to...Technically the SCADA system is composed of the information technology (IT) that provides the human- machine interface (HMI) and stores and analyzes the data...systems work by learning what normal or benign traffic is and reporting on any abnormal traffic. These systems have the potential to detect zero-day
Integrity Verification for SCADA Devices Using Bloom Filters and Deep Packet Inspection
2014-03-27
prevent intrusions in smart grids [PK12]. Parthasarathy proposed an anomaly detection based IDS that takes into account system state. In his implementation...Security, 25(7):498–506, 10 2006. [LMV12] O. Linda, M. Manic, and T. Vollmer. Improving cyber-security of smart grid systems via anomaly detection and...6 2012. 114 [PK12] S. Parthasarathy and D. Kundur. Bloom filter based intrusion detection for smart grid SCADA. In Electrical & Computer Engineering
Application of the SCADA system in wastewater treatment plants.
Dieu, B
2001-01-01
The implementation of the SCADA system has a positive impact on the operations, maintenance, process improvement and savings for the City of Houston's Wastewater Operations branch. This paper will discuss the system's evolvement, the external/internal architecture, and the human-machine-interface graphical design. Finally, it will demonstrate the system's successes in monitoring the City's sewage and sludge collection/distribution systems, wet-weather facilities and wastewater treatment plants, complying with the USEPA requirements on the discharge, and effectively reducing the operations and maintenance costs.
PV-Diesel Hybrid SCADA Experiment Network Design
NASA Technical Reports Server (NTRS)
Kalu, Alex; Durand, S.; Emrich, Carol; Ventre, G.; Wilson, W.; Acosta, R.
1999-01-01
The essential features of an experimental network for renewable power system satellite based supervisory, control and data acquisition (SCADA) are communication links, controllers, diagnostic equipment and a hybrid power system. Required components for implementing the network consist of two satellite ground stations, to satellite modems, two 486 PCs, two telephone receivers, two telephone modems, two analog telephone lines, one digital telephone line, a hybrid-power system equipped with controller and a satellite spacecraft. In the technology verification experiment (TVE) conducted by Savannah State University and Florida Solar Energy Center, the renewable energy hybrid system is the Apex-1000 Mini-Hybrid which is equipped with NGC3188 for user interface and remote control and the NGC2010 for monitoring and basic control tasks. This power system is connected to a satellite modem via a smart interface, RS232. Commands are sent to the power system control unit through a control PC designed as PC1. PC1 is thus connected to a satellite model through RS232. A second PC, designated PC2, the diagnostic PC is connected to both satellite modems via separate analog telephone lines for checking modems'health. PC2 is also connected to PC1 via a telephone line. Due to the unavailability of a second ground station for the ACTS, one ground station is used to serve both the sending and receiving functions in this experiment. Signal is sent from the control PC to the Hybrid system at a frequency f(sub 1), different from f(sub 2), the signal from the hybrid system to the control PC. f(sub l) and f(sub 2) are sufficiently separated to avoid interference.
Enhancing the cyber-security of smart grids with applications to synchrophasor data
NASA Astrophysics Data System (ADS)
Pal, Seemita
In the power grids, Supervisory Control and Data Acquisition (SCADA) systems are used as part of the Energy Management System (EMS) for enabling grid monitoring, control and protection. In recent times, with the ongoing installation of thousands of Phasor Measurement Units (PMUs), system operators are becoming increasingly reliant on PMU-generated synchrophasor measurements for executing wide-area monitoring and real-time control. The availability of PMU data facilitates dynamic state estimation of the system, thus improving the efficiency and resiliency of the grid. Since the SCADA and PMU data are used to make critical control decisions including actuation of physical systems, the timely availability and integrity of this networked data is of paramount importance. Absence or wrong control actions can potentially lead to disruption of operations, monetary loss, damage to equipments or surroundings or even blackout. This has posed new challenges to information security especially in this age of ever-increasing cyber-attacks. In this thesis, potential cyber-attacks on smart grids are presented and effective and implementable schemes are proposed for detecting them. The focus is mainly on three kinds of cyber-attacks and their detection: (i) gray-hole attacks on synchrophasor systems, (ii) PMU data manipulation attacks and (iii) data integrity attacks on SCADA systems. In the case of gray-hole attacks, also known as packet-drop attacks, the adversary may arbitrarily drop PMU data packets as they traverse the network, resulting in unavailability of time-sensitive data for the various critical power system applications. The fundamental challenge is to distinguish packets dropped by the adversary from those that occur naturally due to network congestion.The proposed gray-hole attack detection technique is based on exploiting the inherent timing information in the GPS time-stamped PMU data packets and using the temporal trends of the latencies to classify the cause of packet-drops and finally detect attacks, if any. In the case of PMU data manipulation attacks, the attacker may modify the data in the PMU packets in order to bias the system states and influence the control center into taking wrong decisions. The proposed detection technique is based on evaluating the equivalent impedances of the transmission lines and classifying the observed anomalies to determine the presence of attack and its location. The scheme for detecting data integrity attacks on SCADA systems is based on utilizing synchrophasor measurements from available PMUs in the grid. The proposed method uses a difference measure, developed in this thesis, to determine the relative divergence and mis-correlation between the datasets. Based on the estimated difference measure, tampered and genuine data can be distinguished. The proposed detection mechanisms have demonstrated high accuracy in real-time detection of attacks of various magnitudes, simulated on real PMU data obtained from the NY grid. By performing alarm clustering, the occurrence of false alarms has been reduced to almost zero. The solutions are computationally inexpensive, low on cost, do not add any overhead, and do not require any feedback from the network.
Simulation of wake effects between two wind farms
NASA Astrophysics Data System (ADS)
Hansen, K. S.; Réthoré, P.-E.; Palma, J.; Hevia, B. G.; Prospathopoulos, J.; Peña, A.; Ott, S.; Schepers, G.; Palomares, A.; van der Laan, M. P.; Volker, P.
2015-06-01
SCADA data, recorded on the downstream wind farm, has been used to identify flow cases with visible clustering effects. The inflow condition is derived from a partly undisturbed wind turbine, due to lack of mast measurements. The SCADA data analysis concludes that centre of the deficit for the downstream wind farm with disturbed inflow has a distinct visible maximum deficit zone located only 5-10D downstream from the entrance. This zone, representing 20-30% speed reduction, increases and moves downstream for increasing cluster effect and is not visible outside a flow sector of 20-30°. The eight flow models represented in this benchmark include both RANS models, mesoscale models and engineering models. The flow cases, identified according to the wind speed level and inflow sector, have been simulated and validated with the SCADA results. The model validation concludes that all models more or less are able to predict the location and size of the deficit zone inside the downwind wind farm.
Improving Security for SCADA Sensor Networks with Reputation Systems and Self-Organizing Maps.
Moya, José M; Araujo, Alvaro; Banković, Zorana; de Goyeneche, Juan-Mariano; Vallejo, Juan Carlos; Malagón, Pedro; Villanueva, Daniel; Fraga, David; Romero, Elena; Blesa, Javier
2009-01-01
The reliable operation of modern infrastructures depends on computerized systems and Supervisory Control and Data Acquisition (SCADA) systems, which are also based on the data obtained from sensor networks. The inherent limitations of the sensor devices make them extremely vulnerable to cyberwarfare/cyberterrorism attacks. In this paper, we propose a reputation system enhanced with distributed agents, based on unsupervised learning algorithms (self-organizing maps), in order to achieve fault tolerance and enhanced resistance to previously unknown attacks. This approach has been extensively simulated and compared with previous proposals.
Improving Security for SCADA Sensor Networks with Reputation Systems and Self-Organizing Maps
Moya, José M.; Araujo, Álvaro; Banković, Zorana; de Goyeneche, Juan-Mariano; Vallejo, Juan Carlos; Malagón, Pedro; Villanueva, Daniel; Fraga, David; Romero, Elena; Blesa, Javier
2009-01-01
The reliable operation of modern infrastructures depends on computerized systems and Supervisory Control and Data Acquisition (SCADA) systems, which are also based on the data obtained from sensor networks. The inherent limitations of the sensor devices make them extremely vulnerable to cyberwarfare/cyberterrorism attacks. In this paper, we propose a reputation system enhanced with distributed agents, based on unsupervised learning algorithms (self-organizing maps), in order to achieve fault tolerance and enhanced resistance to previously unknown attacks. This approach has been extensively simulated and compared with previous proposals. PMID:22291569
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lelic, Muhidin; Avramovic, Bozidar; Jiang, Tony
The objective of this project was to demonstrate functionality and performance of a Direct Non-iterative State Estimator (DNSE) integrated with NYPA’s Energy Management System (EMS) and with enhanced Real Time Dynamics Monitoring System (RTDMS) synchrophasor platform from Electric Power Group (EPG). DNSE is designed to overcome a major obstacle to operational use of Synchro-Phasor Management Systems (SPMS) by providing to synchrophasor management systems (SPMS) applications a consistent and a complete synchrophasor data foundation in the same way that a traditional EMS State Estimator (SE) provides to EMS applications. Specifically, DNSE is designed to use synchrophasor measurements collected by a centralmore » PDC, Supervisory Control and Data Acquisition (SCADA) measurements, and Energy Management System (EMS) network model, to obtain the complete state of the utility’s operating model at rates that are close to the synchrophasor data rates. In this way, the system is comprehensive in that it does not only cover the part of the network that is “visible” via synchrophasors, but also the part that is only “visible” through the SCADA measurements. Visualization needs associated with the use of DNSE results are fulfilled through suitably enhanced Real Time Dynamics Monitoring System (RTDMS), with the enhancements implemented by EPG. This project had the following goals in mind: To advance the deployment of commercial grade DNSE software application that relies on synchrophasor and SCADA data ; Apply DNSE at other utilities, to address a generic and fundamental need for “clean” operational data for synchrophasor applications; Provide means for “live” estimated data access by control system operators; Enhance potential for situational awareness through full system operational model coverage; Sub-second execution rate of the Direct Non-iterative State Estimator, eventually at a near-phasor data rate execution speed, i.e. < 0.1 sec. Anticipated benefits from this projects are: Enhanced reliability and improvements in the economic efficiency of bulk power system planning and operations; Providing “clean” data to other synchrophasor applications; Enhancement of situational awareness by providing the full operational model updated at near synchrophasor rate; A production-grade software tool that incorporate synchrophasor and SCADA data; Provides a basis for development of next generation monitoring and control applications, based on both SCADA and PMU data. Quanta Technology (QT) team worked in collaboration with Electric Power Group (EPG) whose team has enhanced its commercial Real Time Dynamics Monitoring System (RTDMS) to accommodate the requirements posed by DNSE application. EPG also provided its ePDC and Model-less Data Conditioning (PDVC) software for integration with DNSE+. QT developed the system requirements for DNSE; developed system architecture and defined interfaces between internal DNSE components. The core DNSE algorithm with all surrounding interfaces was named DNSE+. Since the DNSE development was done in a simulated system environment, QT used its PMU simulator that was enhanced during this project for development and factory acceptance testing (FAT). SCADA data in this stage was simulated by commercial PSS/e software. The output of DNSE are estimates of System states in C37.118-2 format, sent to RTDMS for further processing and display. As the number of these states is large, it was necessary to expand the C37.111-2 standard to accommodate large data sets. This enhancement was implemented in RTDMS. The demonstration of pre-production DNSE technology was done at NYPA using streaming field data from NYPA PMUs and from its RTUs through their SCADA system. NYPA provided ICCP interface as well as Common Information Model (CIM). The relevance of the DNSE+ application is that it provides state estimation of the power system based on hybrid set of data, consisting of both available PMU data and SCADA measurements. As this is a direct, non-iterative method of calculation of the system states, if does not suffer from convergence issues which is potential problem for conventional state estimators. Also, it can take any available PMU measurements, so it does not need to have a high percentage of PMU coverage needed in the case of Linear State Estimator. As the DNSE calculates synchrophasors of the system states (both phase and absolute value) as sub-second rate, this application can provide a basis for development of next generation of applications based both on SCADA and PMU data.« less
A photovoltaic power system in the remote African village of Tangaye, Upper Volta
NASA Technical Reports Server (NTRS)
Bifano, W. J.; Ratajczak, A. F.; Martz, J. E.
1979-01-01
A photovoltaic (PV) system powering a grain mill and a water pump was installed in the remote West African village of Tangaye, Upper Volta. Village characteristics as well as system design, hardware, installation and operation to date are described. The PV system cost is discussed. A baseline socio-economic study performed and a follow-up study is planned to determine the impact of the system on the villagers.
Development and Demonstration of a Security Core Component
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turke, Andy
In recent years, the convergence of a number of trends has resulted in Cyber Security becoming a much greater concern for electric utilities. A short list of these trends includes: · Industrial Control Systems (ICSs) have evolved from depending on proprietary hardware and operating software toward using standard off-the-shelf hardware and operating software. This has meant that these ICSs can no longer depend on “security through obscurity. · Similarly, these same systems have evolved toward using standard communications protocols, further reducing their ability to rely upon obscurity. · The rise of the Internet and the accompanying demand for more datamore » about virtually everything has resulted in formerly isolated ICSs becoming at least partially accessible via Internet-connected networks. · “Cyber crime” has become commonplace, whether it be for industrial espionage, reconnaissance for a possible cyber attack, theft, or because some individual or group “has something to prove.” Electric utility system operators are experts at running the power grid. The reality is, especially at small and mid-sized utilities, these SCADA operators will by default be “on the front line” if and when a cyber attack occurs against their systems. These people are not computer software, networking, or cyber security experts, so they are ill-equipped to deal with a cyber security incident. Cyber Security Manager (CSM) was conceived, designed, and built so that it can be configured to know what a utility’s SCADA/EMS/DMS system looks like under normal conditions. To do this, CSM monitors log messages from any device that uses the syslog standard. It can also monitor a variety of statistics from the computers that make up the SCADA/EMS/DMS: outputs from host-based security tools, intrusion detection systems, SCADA alarms, and real-time SCADA values – even results from a SIEM (Security Information and Event Management) system. When the system deviates from “normal,” CSM can alert the operator in language that they understand that an incident may be occurring, provide actionable intelligence, and informing them what actions to take. These alarms may be viewed on CSM’s built-in user interface, sent to a SCADA alarm list, or communicated via email, phone, pager, or SMS message. In recognition of the fact that “real world” training for cyber security events is impractical, CSM has a built-in Operator Training Simulator capability. This can be used stand alone to create simulated event scenarios for training purposes. It may also be used in conjunction with the recipient’s SCADA/EMS/DMS Operator Training Simulator. In addition to providing cyber security situational awareness for electric utility operators, CSM also provides tools for analysts and support personnel; in fact, the majority of user interface displays are designed for use in analyzing current and past security events. CSM keeps security-related information in long-term storage, as well as writing any decisions it makes to a (syslog) log for use forensic or other post-event analysis.« less
47 CFR 74.434 - Remote control operation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 4 2011-10-01 2011-10-01 false Remote control operation. 74.434 Section 74.434 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... functions to permit proper operation of the station. (b) A remote control system must be designed, installed...
47 CFR 74.434 - Remote control operation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 4 2012-10-01 2012-10-01 false Remote control operation. 74.434 Section 74.434 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... functions to permit proper operation of the station. (b) A remote control system must be designed, installed...
47 CFR 74.434 - Remote control operation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 4 2014-10-01 2014-10-01 false Remote control operation. 74.434 Section 74.434 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... functions to permit proper operation of the station. (b) A remote control system must be designed, installed...
47 CFR 74.434 - Remote control operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false Remote control operation. 74.434 Section 74.434 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... functions to permit proper operation of the station. (b) A remote control system must be designed, installed...
47 CFR 74.434 - Remote control operation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 4 2013-10-01 2013-10-01 false Remote control operation. 74.434 Section 74.434 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... functions to permit proper operation of the station. (b) A remote control system must be designed, installed...
Anomaly-based intrusion detection for SCADA systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, D.; Usynin, A.; Hines, J. W.
2006-07-01
Most critical infrastructure such as chemical processing plants, electrical generation and distribution networks, and gas distribution is monitored and controlled by Supervisory Control and Data Acquisition Systems (SCADA. These systems have been the focus of increased security and there are concerns that they could be the target of international terrorists. With the constantly growing number of internet related computer attacks, there is evidence that our critical infrastructure may also be vulnerable. Researchers estimate that malicious online actions may cause $75 billion at 2007. One of the interesting countermeasures for enhancing information system security is called intrusion detection. This paper willmore » briefly discuss the history of research in intrusion detection techniques and introduce the two basic detection approaches: signature detection and anomaly detection. Finally, it presents the application of techniques developed for monitoring critical process systems, such as nuclear power plants, to anomaly intrusion detection. The method uses an auto-associative kernel regression (AAKR) model coupled with the statistical probability ratio test (SPRT) and applied to a simulated SCADA system. The results show that these methods can be generally used to detect a variety of common attacks. (authors)« less
Modeling And Detecting Anomalies In Scada Systems
NASA Astrophysics Data System (ADS)
Svendsen, Nils; Wolthusen, Stephen
The detection of attacks and intrusions based on anomalies is hampered by the limits of specificity underlying the detection techniques. However, in the case of many critical infrastructure systems, domain-specific knowledge and models can impose constraints that potentially reduce error rates. At the same time, attackers can use their knowledge of system behavior to mask their manipulations, causing adverse effects to observed only after a significant period of time. This paper describes elementary statistical techniques that can be applied to detect anomalies in critical infrastructure networks. A SCADA system employed in liquefied natural gas (LNG) production is used as a case study.
Metrics for the National SCADA Test Bed Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, Philip A.; Mortensen, J.; Dagle, Jeffery E.
2008-12-05
The U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) National SCADA Test Bed (NSTB) Program is providing valuable inputs into the electric industry by performing topical research and development (R&D) to secure next generation and legacy control systems. In addition, the program conducts vulnerability and risk analysis, develops tools, and performs industry liaison, outreach and awareness activities. These activities will enhance the secure and reliable delivery of energy for the United States. This report will describe metrics that could be utilized to provide feedback to help enhance the effectiveness of the NSTB Program.
46 CFR 169.692 - Remote stop stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Machinery and Electrical Electrical Installations on Vessels of 100 Gross Tons and Over § 169.692 Remote... propulsion unit, (b) A bilge slop or dirty oil discharge shutdown at the deck discharge, (c) A ventilation...
Automatic Generation of Supervisory Control System Software Using Graph Composition
NASA Astrophysics Data System (ADS)
Nakata, Hideo; Sano, Tatsuro; Kojima, Taizo; Seo, Kazuo; Uchida, Tomoyuki; Nakamura, Yasuaki
This paper describes the automatic generation of system descriptions for SCADA (Supervisory Control And Data Acquisition) systems. The proposed method produces various types of data and programs for SCADA systems from equipment definitions using conversion rules. At first, this method makes directed graphs, which represent connections between the equipment, from equipment definitions. System descriptions are generated using the conversion rules, by analyzing these directed graphs, and finding the groups of equipment that involve similar operations. This method can make the conversion rules multi levels by using the composition of graphs, and can reduce the number of rules. The developer can define and manage these rules efficiently.
LIDAR wind speed measurements at a Taiwan onshore wind park
NASA Astrophysics Data System (ADS)
Wu, Yu-Ting; Lin, Ta-Hui; Hsuan, Chung-Yao; Li, Yu-Cheng; Yang, Ya-Fei; Tai, Tzy-Hwan; Huang, Chien-Cheng
2016-04-01
Measurements of wind speed and wind direction were carried out using a Leosphere Windcube LIDAR system at a Taiwan onshore wind park. The Lidar shot a total of five laser beams to the atmosphere to collect the light-of-sight (LOS) velocity. Four beams were sent successively in four cardinal directions along a 28° scanning cone angle, followed by a fifth, vertical beam. An unchangeable sampling rate of approximately 1.2 Hz was set in the LIDAR system to collect the LOS velocity. The supervisory control and data acquisition (SCADA) data from two GE 1.5 MW wind turbines near the LIDAR deployment site were acquired for the whole measuring period from February 4 to February 16 of 2015. The SCADA data include the blade angular velocity, the wind velocity measured at hub height from an anemometer mounted on the nacelle, the wind turbine yaw angle, and power production; each parameter was recorded as averages over 1-min periods. The data analysis involving the LIDAR measurements and the SCADA data were performed to obtain the turbulent flow statistics. The results show that the turbine power production has significant dependence to the wind speed, wind direction, turbulence intensity and wind shear.
The ALICE-HMPID Detector Control System: Its evolution towards an expert and adaptive system
NASA Astrophysics Data System (ADS)
De Cataldo, G.; Franco, A.; Pastore, C.; Sgura, I.; Volpe, G.
2011-05-01
The High Momentum Particle IDentification (HMPID) detector is a proximity focusing Ring Imaging Cherenkov (RICH) for charged hadron identification. The HMPID is based on liquid C 6F 14 as the radiator medium and on a 10 m 2 CsI coated, pad segmented photocathode of MWPCs for UV Cherenkov photon detection. To ensure full remote control, the HMPID is equipped with a detector control system (DCS) responding to industrial standards for robustness and reliability. It has been implemented using PVSS as Slow Control And Data Acquisition (SCADA) environment, Programmable Logic Controller as control devices and Finite State Machines for modular and automatic command execution. In the perspective of reducing human presence at the experiment site, this paper focuses on DCS evolution towards an expert and adaptive control system, providing, respectively, automatic error recovery and stable detector performance. HAL9000, the first prototype of the HMPID expert system, is then presented. Finally an analysis of the possible application of the adaptive features is provided.
SIMS prototype system 4 - performance test report
NASA Technical Reports Server (NTRS)
1978-01-01
A self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water was evaluated. Data analysis is included which documents the system performance and verifies its suitability for field installation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCDANIEL, K.S.
1999-09-01
The test procedure provides for verifying indications and alarms The test procedure provides for verifying indications and alarms associated with the B Plant Canyon Ventilation System as they are being displayed on a remote monitoring workstation located in building 271-U. The system application software was installed by PLCS Plus under contract from B&W Hanford Company. The application software was installed on an existing operator workstation in building 271U which is owned and operated by Bechtel Hanford Inc.
Remote Infrared Audible Signage (RIAS) Pilot Program : evaluation report
DOT National Transportation Integrated Search
2009-09-01
This report presents evaluation findings on the Remote Infrared Audible Signage (RIAS) Pilot Program in the Puget Sound Region of Washington. The installation, demonstration and evaluation of RIAS were required by a provision in the Safe, Accountable...
47 CFR 74.634 - Remote control operation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... control system must be designed, installed, and protected so that the transmitter can only be activated or... ensure proper operation. (3) The remote control system must be designed to prevent inadvertent...
47 CFR 74.634 - Remote control operation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... control system must be designed, installed, and protected so that the transmitter can only be activated or... ensure proper operation. (3) The remote control system must be designed to prevent inadvertent...
47 CFR 74.634 - Remote control operation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... control system must be designed, installed, and protected so that the transmitter can only be activated or... ensure proper operation. (3) The remote control system must be designed to prevent inadvertent...
47 CFR 74.634 - Remote control operation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... control system must be designed, installed, and protected so that the transmitter can only be activated or... ensure proper operation. (3) The remote control system must be designed to prevent inadvertent...
47 CFR 74.634 - Remote control operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES EXPERIMENTAL RADIO... control system must be designed, installed, and protected so that the transmitter can only be activated or... ensure proper operation. (3) The remote control system must be designed to prevent inadvertent...
Analysis of data throughput in communication between PLCs and HMI/SCADA systems
NASA Astrophysics Data System (ADS)
Mikolajek, Martin; Koziorek, Jiri
2016-09-01
This paper is focused on Analysis of data throughout in communication between PLCs and HMI/SCADA systems. The first part of paper discusses basic problematic communication between PLC and HMI systems. Next part is about specific types of communications PLC - HMI requests. For those cases paper is talking about response and data throughput1-3 . Subsequent section of this article contains practical parts with various data exchanges between PLC Siemens and HMI. The possibilities of communication that are described in this article are focused on using OPC server for visualization software, custom HMI system and own application created by using .NET with Technology. The last part of this article contains some communication solutions.
Anomaly Detection in Power Quality at Data Centers
NASA Technical Reports Server (NTRS)
Grichine, Art; Solano, Wanda M.
2015-01-01
The goal during my internship at the National Center for Critical Information Processing and Storage (NCCIPS) is to implement an anomaly detection method through the StruxureWare SCADA Power Monitoring system. The benefit of the anomaly detection mechanism is to provide the capability to detect and anticipate equipment degradation by monitoring power quality prior to equipment failure. First, a study is conducted that examines the existing techniques of power quality management. Based on these findings, and the capabilities of the existing SCADA resources, recommendations are presented for implementing effective anomaly detection. Since voltage, current, and total harmonic distortion demonstrate Gaussian distributions, effective set-points are computed using this model, while maintaining a low false positive count.
FDI and Accommodation Using NN Based Techniques
NASA Astrophysics Data System (ADS)
Garcia, Ramon Ferreiro; de Miguel Catoira, Alberto; Sanz, Beatriz Ferreiro
Massive application of dynamic backpropagation neural networks is used on closed loop control FDI (fault detection and isolation) tasks. The process dynamics is mapped by means of a trained backpropagation NN to be applied on residual generation. Process supervision is then applied to discriminate faults on process sensors, and process plant parameters. A rule based expert system is used to implement the decision making task and the corresponding solution in terms of faults accommodation and/or reconfiguration. Results show an efficient and robust FDI system which could be used as the core of an SCADA or alternatively as a complement supervision tool operating in parallel with the SCADA when applied on a heat exchanger.
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
10 CFR 35.605 - Installation, maintenance, adjustment, and repair.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Installation, maintenance, adjustment, and repair. 35.605 Section 35.605 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and Gamma Stereotactic Radiosurgery Units § 35.605...
SCADA-based Operator Support System for Power Plant Equipment Fault Forecasting
NASA Astrophysics Data System (ADS)
Mayadevi, N.; Ushakumari, S. S.; Vinodchandra, S. S.
2014-12-01
Power plant equipment must be monitored closely to prevent failures from disrupting plant availability. Online monitoring technology integrated with hybrid forecasting techniques can be used to prevent plant equipment faults. A self learning rule-based expert system is proposed in this paper for fault forecasting in power plants controlled by supervisory control and data acquisition (SCADA) system. Self-learning utilizes associative data mining algorithms on the SCADA history database to form new rules that can dynamically update the knowledge base of the rule-based expert system. In this study, a number of popular associative learning algorithms are considered for rule formation. Data mining results show that the Tertius algorithm is best suited for developing a learning engine for power plants. For real-time monitoring of the plant condition, graphical models are constructed by K-means clustering. To build a time-series forecasting model, a multi layer preceptron (MLP) is used. Once created, the models are updated in the model library to provide an adaptive environment for the proposed system. Graphical user interface (GUI) illustrates the variation of all sensor values affecting a particular alarm/fault, as well as the step-by-step procedure for avoiding critical situations and consequent plant shutdown. The forecasting performance is evaluated by computing the mean absolute error and root mean square error of the predictions.
Water survey of Canada: Application for use of ERTS-A for retransmission of water resources data
NASA Technical Reports Server (NTRS)
Halliday, R. A. (Principal Investigator)
1973-01-01
The author has identified the following significant results. Nine sites in isolated regions in Canada have been selected for installation of ERTS data collection platforms. Seven platforms were installed in 1972, one of which did not operate. The six operating platforms transmitted over 7000 water level readings from stream gauging stations. This data is available on a near real time basis through the Canada Center for Remote Sensing and is used for river flow forecasting. The practicability of using satellite retransmission as a means of obtaining data from remote areas has been demonstrated.
CARRIER PREPARATION BUILDING MATERIALS HANDLING SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
E.F. Loros
2000-06-28
The Carrier Preparation Building Materials Handling System receives rail and truck shipping casks from the Carrier/Cask Transport System, and inspects and prepares the shipping casks for return to the Carrier/Cask Transport System. Carrier preparation operations for carriers/casks received at the surface repository include performing a radiation survey of the carrier and cask, removing/retracting the personnel barrier, measuring the cask temperature, removing/retracting the impact limiters, removing the cask tie-downs (if any), and installing the cask trunnions (if any). The shipping operations for carriers/casks leaving the surface repository include removing the cask trunnions (if any), installing the cask tie-downs (if any), installingmore » the impact limiters, performing a radiation survey of the cask, and installing the personnel barrier. There are four parallel carrier/cask preparation lines installed in the Carrier Preparation Building with two preparation bays in each line, each of which can accommodate carrier/cask shipping and receiving. The lines are operated concurrently to handle the waste shipping throughputs and to allow system maintenance operations. One remotely operated overhead bridge crane and one remotely operated manipulator is provided for each pair of carrier/cask preparation lines servicing four preparation bays. Remotely operated support equipment includes a manipulator and tooling and fixtures for removing and installing personnel barriers, impact limiters, cask trunnions, and cask tie-downs. Remote handling equipment is designed to facilitate maintenance, dose reduction, and replacement of interchangeable components where appropriate. Semi-automatic, manual, and backup control methods support normal, abnormal, and recovery operations. Laydown areas and equipment are included as required for transportation system components (e.g., personnel barriers and impact limiters), fixtures, and tooling to support abnormal and recovery operations. The Carrier Preparation Building Materials Handling System interfaces with the Cask/Carrier Transport System to move the carriers to and from the system. The Carrier Preparation Building System houses the equipment and provides the facility, utility, safety, communications, and auxiliary systems supporting operations and protecting personnel.« less
Full load estimation of an offshore wind turbine based on SCADA and accelerometer data
NASA Astrophysics Data System (ADS)
Noppe, N.; Iliopoulos, A.; Weijtjens, W.; Devriendt, C.
2016-09-01
As offshore wind farms (OWFs) grow older, the optimal use of the actual fatigue lifetime of an offshore wind turbine (OWT) and predominantly its foundation will get more important. In case of OWTs, both quasi-static wind/thrust loads and dynamic loads, as induced by turbulence, waves and the turbine's dynamics, contribute to its fatigue life progression. To estimate the remaining useful life of an OWT, the stresses acting on the fatigue critical locations within the structure should be monitored continuously. Unfortunately, in case of the most common monopile foundations these locations are often situated below sea-level and near the mud line and thus difficult or even impossible to access for existing OWTs. Actual strain measurements taken at accessible locations above the sea level show a correlation between thrust load and several SCADA parameters. Therefore a model is created to estimate the thrust load using SCADA data and strain measurements. Afterwards the thrust load acting on the OWT is estimated using the created model and SCADA data only. From this model the quasi static loads on the foundation can be estimated over the lifetime of the OWT. To estimate the contribution of the dynamic loads a modal decomposition and expansion based virtual sensing technique is applied. This method only uses acceleration measurements recorded at accessible locations on the tower. Superimposing both contributions leads to a so-called multi-band virtual sensing. The result is a method that allows to estimate the strain history at any location on the foundation and thus the full load, being a combination of both quasi-static and dynamic loads, acting on the entire structure. This approach is validated using data from an operating Belgian OWF. An initial good match between measured and predicted strains for a short period of time proofs the concept.
ERIC Educational Resources Information Center
D'Alessandro, Bill
1979-01-01
Describes the world's only solar electric village power system, a photovoltaic conversion installation in a remote Papago Indian Reservation village. Notes comparative costs, electric output, and potential applications of the system, a prototype for remote rural communities and developing nations. Notes outstanding questions and key issues in…
Evaluation of "Autosense-III" laser detection technology for traffic applications on I-4
DOT National Transportation Integrated Search
2001-11-01
The major tasks of this project include procuring the two AUTOSENSE III units; selecting a site on I-4 for installation of the units, installing the units successfully on I-4, establishing a remote communication link through cellular data line to dow...
PV systems for remote villages: Service-learning and communal sharing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duffy, J.; Soper, P.; Prasitpianchai, S.
1999-07-01
The remote village of Malvas in the Andes seems typical of many in Peru. The 500 descendants of the Quechua once ruled by the Inca have no electricity, no running water, one telephone, and mud adobe houses. At a 10,000-foot altitude, residents survive with subsistence farming. A group designed and installed a photovoltaic system to provide a vaccine refrigerator, lights, and a transceiver radio system in the town medical clinic last August. They installed light systems in four other town medical clinics in January. This project involves service-learning: combining service with academic subject matter, in this case solar engineering. Keymore » elements of the project also include: letting people define their needs, sustainable infrastructure development, community sharing of installation and virtual ownership (to go along with almost everything else that is shared in common).« less
NASA Astrophysics Data System (ADS)
Sakaguchi, Hideharu
Do you remember an expert system? I think there are various impressions about the system. For example, some might say “It reminds me of old days”. On the other hand, some might say “It was really troublesome”. About 25 years ago, from late 1980s to the middle of 1990s, when the Showa era was about to change into the Heisei Era, artificial intelligence boomed. Research and development for an expert system which was equipped with expertise and worked as smart as expert, was advanced in various fields. Our company also picked up the system as the new system which covered weak point of conventional computer technology. We started research and development in 1984, and installed an expert system in a SCADA system, which started operating in March 1990 in the Fukuoka Integrated Control Center. In this essay, as an electric power engineer who involved in development at that time, I introduce the situation and travail story about developing an expert system which support restorative actions from the outage and overload condition of power networks.
NASA Astrophysics Data System (ADS)
Hanai, Yuji; Hayashi, Yasuhiro; Matsuki, Junya
The line voltage control in a distribution network is one of the most important issues for a penetration of Renewable Energy Sources (RES). A loop distribution network configuration is an effective solution to resolve voltage and distribution loss issues concerned about a penetration of RES. In this paper, for a loop distribution network, the authors propose a voltage control method based on tap change control of LRT and active/reactive power control of RES. The tap change control of LRT takes a major role of the proposed voltage control. Additionally the active/reactive power control of RES supports the voltage control when voltage deviation from the upper or lower voltage limit is unavoidable. The proposed method adopts SCADA system based on measured data from IT switches, which are sectionalizing switch with sensor installed in distribution feeder. In order to check the validity of the proposed voltage control method, experimental simulations using a distribution system analog simulator “ANSWER” are carried out. In the simulations, the voltage maintenance capability in the normal and the emergency is evaluated.
Code of Federal Regulations, 2013 CFR
2013-07-01
... office. A branch bank, or independent bank operated by a banking institution on a domestic DoD installation or by a foreign banking institution on an overseas DoD installation. (d) Branch bank. A separate... business at remote locations where a full-service credit union or credit union branch is impractical...
Code of Federal Regulations, 2014 CFR
2014-07-01
... office. A branch bank, or independent bank operated by a banking institution on a domestic DoD installation or by a foreign banking institution on an overseas DoD installation. (d) Branch bank. A separate... business at remote locations where a full-service credit union or credit union branch is impractical...
Code of Federal Regulations, 2011 CFR
2011-07-01
... office. A branch bank, or independent bank operated by a banking institution on a domestic DoD installation or by a foreign banking institution on an overseas DoD installation. (d) Branch bank. A separate... business at remote locations where a full-service credit union or credit union branch is impractical...
Code of Federal Regulations, 2012 CFR
2012-07-01
... office. A branch bank, or independent bank operated by a banking institution on a domestic DoD installation or by a foreign banking institution on an overseas DoD installation. (d) Branch bank. A separate... business at remote locations where a full-service credit union or credit union branch is impractical...
47 CFR 78.51 - Remote control operation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... control system shall be installed and protected in a manner designed to prevent tampering or operation by... transmissions and a carrier operated device which will give a continuous visual indication whenever the... necessary to insure proper operation. (4) The control circuits shall be so designed and installed that short...
47 CFR 78.51 - Remote control operation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... control system shall be installed and protected in a manner designed to prevent tampering or operation by... transmissions and a carrier operated device which will give a continuous visual indication whenever the... necessary to insure proper operation. (4) The control circuits shall be so designed and installed that short...
Installation and assembly device and method of using
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolsun, G.J.
1995-12-31
The present invention relates to an installation and assembly device and method for facilitating the fitup of mating components during blind or remote installation and assembly, especially where close fitup tolerances are involved. The present invention is particularly useful for the purpose of facilitating vertical and/or radial relative positioning of a pump impeller within a mating inlet nozzle during a blind assembly wherein actual fitup cannot be observed during installation. The information within identifies just one successful application of the installation and assembly alignment device for a pump. The device, however, is not solely limited to pump assembly but canmore » be used in other cases where fitup of a sleeve inside a mating bore is required under conditions of close tolerance during a blind or remote assembly. The device is likewise not limited to circular configurations but can be used for many other shapes or configurations. Any material that can be machined and hold reasonably close tolerances can be used for the device. Also, because the sleeve position is adjusted by set screws or bolts, the concentricity can be radially biased, if required, to achieve particular alignment conditions.« less
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2011 CFR
2011-07-01
... remote steering gear control system. (ii) Each steering position located on the navigating bridge. (iii) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle indicator in relation to the actual position of the rudder. (v) Each remote steering gear control system...
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2010 CFR
2010-07-01
... remote steering gear control system. (ii) Each steering position located on the navigating bridge. (iii) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle indicator in relation to the actual position of the rudder. (v) Each remote steering gear control system...
Very Portable Remote Automatic Weather Stations
John R. Warren
1987-01-01
Remote Automatic Weather Stations (RAWS) were introduced to Forest Service and Bureau of Land Management field units in 1978 following development, test, and evaluation activities conducted jointly by the two agencies. The original configuration was designed for semi-permanent installation. Subsequently, a need for a more portable RAWS was expressed, and one was...
Remote sensing of an agricultural soil moisture network in Walnut Creek, Iowa
USDA-ARS?s Scientific Manuscript database
The calibration and validation of soil moisture remote sensing products is complicated by the logistics of installing a soil moisture network for a long term period in an active landscape. Usually soil moisture sensors are added to existing precipitation networks which have as a singular requiremen...
ERIC Educational Resources Information Center
Roman, Harry T.
2013-01-01
The ability to remotely inspect equipment of an aging infrastructure is becoming of major interest to many industries. Often the ability to just get a look at a piece of critical equipment can yield very important information. With millions of miles of piping installed throughout the United States, this vast network is critical to oil, natural…
Physical-mathematical model of optical radiation interaction with biological tissues
NASA Astrophysics Data System (ADS)
Kozlovska, Tetyana I.; Kolisnik, Peter F.; Zlepko, Sergey M.; Titova, Natalia V.; Pavlov, Volodymyr S.; Wójcik, Waldemar; Omiotek, Zbigniew; Kozhambardiyeva, Miergul; Zhanpeisova, Aizhan
2017-08-01
Remote photoplethysmography (PPG) imaging is an optical technique to remotely assess the local coetaneous microcirculation. In this paper, we present a model and supporting experiments confirming the contribution of skin inhomogeneity to the morphology of PPG waveforms. The physical-mathematical model of distribution of optical radiation in biological tissues was developed. It allows determining the change of intensity of optical radiation depending on such parameters as installation angle of the sensor, biological tissue thickness and the wavelength. We obtained graphics which represent changes of the optical radiation intensity that is registered by photodetector depending on installation angle of the sensor, biological tissue thickness and the extinction coefficient.
NASA Astrophysics Data System (ADS)
Iungo, Giacomo Valerio; Camarri, Simone; Ciri, Umberto; El-Asha, Said; Leonardi, Stefano; Rotea, Mario A.; Santhanagopalan, Vignesh; Viola, Francesco; Zhan, Lu
2016-11-01
Site conditions, such as topography and local climate, as well as wind farm layout strongly affect performance of a wind power plant. Therefore, predictions of wake interactions and their effects on power production still remain a great challenge in wind energy. For this study, an onshore wind turbine array was monitored through lidar measurements, SCADA and met-tower data. Power losses due to wake interactions were estimated to be approximately 4% and 2% of the total power production under stable and convective conditions, respectively. This dataset was then leveraged for the calibration of a data driven RANS (DDRANS) solver, which is a compelling tool for prediction of wind turbine wakes and power production. DDRANS is characterized by a computational cost as low as that for engineering wake models, and adequate accuracy achieved through data-driven tuning of the turbulence closure model. DDRANS is based on a parabolic formulation, axisymmetry and boundary layer approximations, which allow achieving low computational costs. The turbulence closure model consists in a mixing length model, which is optimally calibrated with the experimental dataset. Assessment of DDRANS is then performed through lidar and SCADA data for different atmospheric conditions. This material is based upon work supported by the National Science Foundation under the I/UCRC WindSTAR, NSF Award IIP 1362033.
Using SCADA Data, Field Studies, and Real-Time Modeling to ...
EPA has been providing technical assistance to the City of Flint and the State of Michigan in response to the drinking water lead contamination incident. Responders quickly recognized the need for a water distribution system hydraulic model to provide insight on flow patterns and water quality as well as to evaluate changes being made to the system operation to enhance corrosion control and improve chlorine residuals. EPA partnered with the City of Flint and the Michigan Department of Environmental Quality to update and calibrate an existing hydraulic model. The City provided SCADA data, GIS data, customer billing data, valve status data, design diagrams, and information on operations. Team members visited all facilities and updated pump and valve types, sizes, settings, elevations, and pump discharge curves. Several technologies were used to support this work including the EPANET-RTX based Polaris real-time modeling software, WaterGEMS, ArcGIS, EPANET, and RTX:LINK. Field studies were conducted to collect pressure and flow data from more than 25 locations throughout the distribution system. An assessment of the model performance compared model predictions for flow, pressure, and tank levels to SCADA and field data, resulting in error measurements for each data stream over the time period analyzed. Now, the calibrated model can be used with a known confidence in its performance to evaluate hydraulic and water quality problems, and the model can be easily
Tappura, K
2001-08-15
An adjustable-barrier dihedral angle potential was added as an extension to a novel, previously presented soft-core potential to study its contribution to the efficacy of the search of the conformational space in molecular dynamics. As opposed to the conventional soft-core potential functions, the leading principle in the design of the new soft-core potential, as well as of its extension, the soft-core and adjustable-barrier dihedral angle (SCADA) potential (referred as the SCADA potential), was to maintain the main equilibrium properties of the original force field. This qualifies the methods for a variety of a priori modeling problems without need for additional restraints typically required with the conventional soft-core potentials. In the present study, the different potential energy functions are applied to the problem of predicting loop conformations in proteins. Comparison of the performance of the soft-core and SCADA potential showed that the main hurdles for the efficient sampling of the conformational space of (loops in) proteins are related to the high-energy barriers caused by the Lennard-Jones and Coulombic energy terms, and not to the rotational barriers, although the conformational search can be further enhanced by lowering the rotational barriers of the dihedral angles. Finally, different evaluation methods were studied and a few promising criteria found to distinguish the near-native loop conformations from the wrong ones.
A demonstrator for an integrated subway protection system
NASA Astrophysics Data System (ADS)
Detoma, E.; Capetti, P.; Casati, G.; Billington, S.
2008-04-01
In 2006 SEPA has carried on the installation and tests of a demonstrator for an integrated subway protection system at a new subway station in the Naples, Italy) metropolitan area. Protection of a subway system is a difficult task given the amount of passengers transported every day. The demonstrator has been limited to non-intrusive detection techniques not to impair the passenger flow into the station. The demonstrator integrates several technologies and products that have been developed by SEPA or are already available on the market (MKS Instruments,...). The main purpose is to provide detection capabilities for attempts to introduce radioactive substances in the subway station, in order to foil possible attempts to place a dirty bomb, and threat detection and identification following release of chemical agents. The system integrates additional sensors such as video surveillance cameras and air flow sensing to complement the basic sensors suite. The need to protect sensitive installations such as subway stations has been highlighted by the series of terroristics actions carried out in recent years in the subway in London. However, given the number of passengers of a metro system, it is impossible to propose security techniques operating in ways similar to the screening of passengers in airports. Passengers screening and threat detection and identification must be quick, non-intrusive and capable of screening a large number of passengers to be applicable to mass transit systems. In 2005 SEPA, a small company operating in the field of trains video-surveillance systems and radiation detectors, started developing an integrated system to provide a comprehensive protection to subway stations, based on ready available or off-the-shelf components in order to quickly develop a reliable system with available technology. We ruled out at the beginning any new development in order to speed up the fielding of the system in less than one year. The system was developed with commercial sensors and deployed in a new station of the Naples metropolitan transit system in Mugnano. The station was particularly suitable for the demonstration since it is a new station that includes air venting control, water barriers (for fire and smoke containment) and a complete SCADA system to integrate technical and video surveillance operations. In order to protect the subway, we tackled four basic technologies, all readily available in-house or on the market: - radiation detection, to detect the introduction in the station of radionuclides, that may be dispersed by conventional explosive (a "dirty" bomb); - chemical agents detection and identification (after release), complemented with air speed and velocity sensors to estimate, track and predict the contamination plume; - video surveillance, integrated with the SCADA system and already available in the station.
Practical lessons in remote connectivity.
Kouroubali, A.; Starren, J.; Barrows, R. C.; Clayton, P. D.
1997-01-01
Community Health Information Networks (CHINs) require the ability to provide computer network connections to many remote sites. During the implementation of the Washington Heights and Inwood Community Health Management Information System (WHICHIS) at the Columbia-Presbyterian Medical Center (CPMC), a number of remote connectivity issues have been encountered. Both technical and non-technical issues were significant during the installation. We developed a work-flow model for this process which may be helpful to any health care institution attempting to provide seamless remote connectivity. This model is presented and implementation lessons are discussed. PMID:9357643
Zirconium Recycle Test Equipment for Hot Cell Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collins, Emory D.; DelCul, Guillermo Daniel; Spencer, Barry B.
2015-01-30
The equipment components and assembly support work were modified for optimized, remote hot cell operations to complete this milestone. The modifications include installation of a charging door, Swagelok connector for the off-gas line between the reactor and condenser, and slide valve installation to permit attachment/replacement of the product salt collector bottle.
NASA Astrophysics Data System (ADS)
Krämer, Sebastian G. M.; Wiesent, Benjamin; Müller, Mathias S.; Puente León, Fernando; Méndez Hernández, Yarú
2008-04-01
Wind turbine blades are made of composite materials and reach a length of more than 42 meters. Developments for modern offshore turbines are working on about 60 meters long blades. Hence, with the increasing height of the turbines and the remote locations of the structures, health monitoring systems are becoming more and more important. Therefore, fiber-optic sensor systems are well-suited, as they are lightweight, immune against electromagnetic interference (EMI), and as they can be multiplexed. Based on two separately existing concepts for strain measurements and lightning detection on wind turbines, a fused system is presented. The strain measurement system is based on a reflective fiber-Bragg-grating (FBG) network embedded in the composite structure of the blade. For lightning detection, transmissive &fiber-optic magnetic field sensors based on the Faraday effect are used to register the lightning parameters and estimate the impact point. Hence, an existing lightning detection system will be augmented, due to the fusion, by the capability to measure strain, temperature and vibration. Load, strain, temperature and impact detection information can be incorporated into the turbine's monitoring or SCADA system and remote controlled by operators. Data analysis techniques allow dynamic maintenance scheduling to become a reality, what is of special interest for the cost-effective maintenance of large offshore or badly attainable onshore wind parks. To prove the feasibility of this sensor fusion on one optical fiber, interferences between both sensor systems are investigated and evaluated.
2005-11-10
KENNEDY SPACE CENTER, FLA. - In NASA Kennedy Space Center’s Orbiter Processing Facility Bay 3, a remote manipulator system, or space shuttle arm, previously installed on the orbiter Atlantis, is being installed in Discovery’s payload bay. The arms were switched because the arm that was installed on Atlantis has special instrumentation to gather loads data from the second return-to-flight mission, STS-121. Discovery is the designated orbiter to fly on STS-121. scheduled to launch no earlier than May 2006.
2005-11-10
KENNEDY SPACE CENTER, FLA. - In NASA Kennedy Space Center’s Orbiter Processing Facility Bay 3, a remote manipulator system, or space shuttle arm, previously installed on the orbiter Atlantis, is being installed in Discovery’s payload bay. The arms were switched because the arm that was installed on Atlantis has special instrumentation to gather loads data from the second return-to-flight mission, STS-121. Discovery is the designated orbiter to fly on STS-121. scheduled to launch no earlier than May 2006.
2005-11-10
KENNEDY SPACE CENTER, FLA. - In NASA Kennedy Space Center’s Orbiter Processing Facility Bay 3, technicians install a remote manipulator system, or space shuttle arm, previously installed on the orbiter Atlantis, in Discovery’s payload bay. The arms were switched because the arm that was installed on Atlantis has special instrumentation to gather loads data from the second return-to-flight mission, STS-121. Discovery is the designated orbiter to fly on STS-121. scheduled to launch no earlier than May 2006.
2005-11-10
KENNEDY SPACE CENTER, FLA. - In NASA Kennedy Space Center’s Orbiter Processing Facility Bay 3, technicians install a remote manipulator system, or space shuttle arm, previously installed on the orbiter Atlantis, in Discovery’s payload bay. The arms were switched because the arm that was installed on Atlantis has special instrumentation to gather loads data from the second return-to-flight mission, STS-121. Discovery is the designated orbiter to fly on STS-121. scheduled to launch no earlier than May 2006.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2012-08-09
Sophia Daemon Version 12 contains the code that is exclusively used by the sophiad application. It runs as a service on a Linux host and analyzes network traffic obtained from libpcap and produces a network fingerprint based on hosts and channels. Sophia Daemon Version 12 can, if desired by the user, produce alerts when its fingerprint changes. Sophia Daemon Version 12 can receive data from another Sophia Daemon or raw packet data. It can output data to another Sophia Daemon Version 12, OglNet Version 12 or MySQL. Sophia Daemon Version 12 runs in a passive real-time manner that allows itmore » to be used on a SCADA network. Its network fingerprint is designed to be applicable to SCADA networks rather than general IT networks.« less
46 CFR 129.540 - Remote stopping-systems on OSVs of 100 or more gross tons.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Miscellaneous Electrical Systems § 129.540 Remote stopping... subpart 111.103 of this chapter: (1) For each propulsion unit, in the pilothouse. (2) For each discharge pump for bilge slop or dirty oil, at the deck discharge. (3) For each powered ventilation system...
NASA Astrophysics Data System (ADS)
Rajewski, D. A.
2015-12-01
Wind farms are an important resource for electrical generation in the Central U.S., however with each installation there are many poorly documented interactions with the local and surrounding environment. The impact of wind farms on surface microclimate is largely understood conceptually using numerical or wind tunnel models or ex situ satellite-detected changes. Measurements suitable for calibration of numerical simulations are few and of limited applicability but are urgently needed to improve parameterization of wind farm aerodynamics influenced by the diurnal evolution of the boundary layer. Among large eddy simulations of wind farm wakes in thermally stable stratification, there are discrepancies on the influence of turbine-induced mixing on the surface heat flux. We provide measurements from seven surface flux stations, vertical profiling LiDARs located upwind and downwind of turbines, and SCADA measurements from turbines during the 2013 Crop Wind Energy Experiment (CWEX-13) as the best evidence for the variability of turbine induced heat flux within a large wind farm. Examination of ambient conditions (wind direction, wind veer, and thermal stratification) and on turbine operation factors (hub-height wind speed, normalized power) reveal conditions that lead to the largest modification of heat flux. Our results demonstrate the highest flux change from the reference station to be where the leading few lines of turbines influence the surface. Under stably stratified conditions turbine-scale turbulence is highly efficient at bringing warmer air aloft to the surface, leading to an increase in downward heat flux. Conversely we see that the combination of wakes from several lines of turbines reduces the flux contrast from the reference station. In this regime of deep wind-farm flow, wake turbulence is similar in scale and intensity to the reference conditions. These analysis tools can be extended to other turbine SCADA and microclimate variables (e.g. temperature) to improve basic understanding of turbine-turbine and total wind farm wake interactions. Forthcoming tall-tower measurements will provide additional opportunities for comparison of simulated wind and thermal profiles in non-wake, and waked flow conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, S.; Lucero, R.; Glidewell, D.
1997-08-01
The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. Thismore » paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs.« less
NASA Astrophysics Data System (ADS)
Hernandez, C.
2010-09-01
The weakness of small island electrical grids implies a handicap for the electrical generation with renewable energy sources. With the intention of maximizing the installation of photovoltaic generators in the Canary Islands, arises the need to develop a solar forecasting system that allows knowing in advance the amount of PV generated electricity that will be going into the grid, from the installed PV power plants installed in the island. The forecasting tools need to get feedback from real weather data in "real time" from remote weather stations. Nevertheless, the transference of this data to the calculation computer servers is very complicated with the old point to point telecommunication systems that, neither allow the transfer of data from several remote weather stations simultaneously nor high frequency of sampling of weather parameters due to slowness of the connection. This one project has developed a telecommunications infrastructure that allows sensorizadas remote stations, to send data of its sensors, once every minute and simultaneously, to the calculation server running the solar forecasting numerical models. For it, the Canary Islands Institute of Technology has added a sophisticated communications network to its 30 weather stations measuring irradiation at strategic sites, areas with high penetration of photovoltaic generation or that have potential to host in the future photovoltaic power plants connected to the grid. In each one of the stations, irradiance and temperature measurement instruments have been installed, over inclined silicon cell, global radiation on horizontal surface and room temperature. Mobile telephone devices have been installed and programmed in each one of the weather stations, which allow the transfer of their data taking advantage of the UMTS service offered by the local telephone operator. Every minute the computer server running the numerical weather forecasting models receives data inputs from 120 instruments distributed over the 30 radiometric stations. As a the result, currently it exist a stable, flexible, safe and economic infrastructure of radiometric stations and telecommunications that allows, on the one hand, to have data in real time from all 30 remote weather stations, and on the other hand allows to communicate with them in order to reprogram them and to carry out maintenance works.
NASA Technical Reports Server (NTRS)
Allen, M. A.; Roman, G. S.
1979-01-01
The specification used to install a broadband coaxial cable communication system to support remote terminal operations on the Crew Activity Planning system at the Lyndon B. Johnson Space Center are reported. The system supports high speed communications between a Harris Slash 8 computer and one or more Sanders Graphic 7 displays.
Photographic copy of photograph, dated September 1971, (original print in ...
Photographic copy of photograph, dated September 1971, (original print in possession of CSSD-HO, Huntsville, AL). Photographer unknown. Aerial view looking north of remote sprint launch site #2, during construction. In the foreground is the remote launch operations building (RLOB); sprint silos are being installed in the background - Stanley R. Mickelsen Safeguard Complex, Remote Sprint Launch Site No. 2, West of Mile Marker 220 on State Route 1, 6.0 miles North of Langdon, ND, Nekoma, Cavalier County, ND
A Taxonomy of Attacks on the DNP3 Protocol
NASA Astrophysics Data System (ADS)
East, Samuel; Butts, Jonathan; Papa, Mauricio; Shenoi, Sujeet
Distributed Network Protocol (DNP3) is the predominant SCADA protocol in the energy sector - more than 75% of North American electric utilities currently use DNP3 for industrial control applications. This paper presents a taxonomy of attacks on the protocol. The attacks are classified based on targets (control center, outstation devices and network/communication paths) and threat categories (interception, interruption, modification and fabrication). To facilitate risk analysis and mitigation strategies, the attacks are associated with the specific DNP3 protocol layers they exploit. Also, the operational impact of the attacks is categorized in terms of three key SCADA objectives: process confi- dentiality, process awareness and process control. The attack taxonomy clarifies the nature and scope of the threats to DNP3 systems, and can provide insights into the relative costs and benefits of implementing mitigation strategies.
Recent Experience with a Hybrid SCADA/PMU On-Line State Estimator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizy, D Tom
2009-01-01
PMU devices are expected to grow in number from a few to several hundreds in the next five years. Some relays are already global positioning system-capable and could provide the same type of data as any PMU. This introduces a new paradigm of very fast accurate synchrophasor measurements from across the grid in real-time that augment and parallel existing slower SCADA measurements. Control center applications will benefit from this PMU data; for example, use of PMU data in state estimation is expected to improve accuracy and robustness, which in turn will result in more timely and accurate N-1 security analysis,more » resulting in an overall improvement of grid system reliability and security. This paper describes results from a recent implementation of this technology, the benefits and future work.« less
Cell-phone based assistance for waterworks/sewage plant maintenance.
Kawada, T; Nakamichi, K; Hisano, N; Kitamura, M; Miyahara, K
2006-01-01
Cell-phones are now incorporating the functions necessary for them to be used as mobile IT devices. In this paper, we present our results of the evaluation of cell-phones as the mobile IT device to assist workers in industrial plants. We use waterworks and sewage plants as examples. By employing techniques to squeeze the SCADA screen on CRT into a small cell-phone LCD, we have made it easier for a plant's field workers to access the information needed for effective maintenance, regardless of location. An idea to link SCADA information and the plant facility information on the cell-phone is also presented. Should an accident or emergency situation arise, these cell-phone-based IT systems can efficiently deliver the latest plant information, thus the worker out in the field can respond to and resolve the emergency.
Usachev and Helms install SSRMS cables
2001-03-30
ISS002E5480 (30 March 2001) --- Cosmonaut Yury V. Usachev (foreground), Expedition Two mission commander, and astronaut Susan J. Helms, Expedition Two flight engineer, install cables for the Space Station Remote Manipulator System (SSRMS) or Canadarm2 control panel in preparation for the delivery of the Canadarm2 by the STS-100 crew in April. This image was recorded with a digital still camera.
Improved corrosion control by coating in the splash zone and subsea
DOE Office of Scientific and Technical Information (OSTI.GOV)
John, R.C.; VanHooff, W.
1989-01-01
The splash zone around offshore structures is without doubt one of nature's most hostile and corrosive environments. Apart from the wave impacts, plentiful supplies of oxygen, lack of cathodic protection, and the salt spray that continually wets and then dries upon objects, the region is difficult and sometimes dangerous to access. This article reviews the performance of two new offshore repair coatings recently installed on North Sea and Gulf of Mexico installations. The first coating, a reinforced heat-shrinkable sleeve, is designed to be installed over properly cleaned and dried steel surfaces. Suitable conditions for the application of this coating existmore » during low tide and calm weather when certain exposed sections of the splash zone are accessible. Alternatively, by using a special remote-controlled cofferdam chamber to create an artificial local environment, subsea coating application can proceed under ideal conditions. Cofferdam chamber installations are diver-free and can be made throughout the entire splash zone, even during rough weather. When a remote-controlled cofferdam is not available and repairs are needed in subsea or wet areas, diver assistance is usually required. The second coating system, a gel-based, diver-applied tape, has been developed specifically for such applications.« less
Kostyukevich, Yury; Efremov, Denis; Ionov, Vladimir; Kukaev, Eugene; Nikolaev, Eugene
2017-11-01
The detection of explosives and drugs in hard-to-reach places is a considerable challenge. We report the development and initial experimental characterization of the air analysis system that includes Field Asymmetric Ion Mobility Spectrometer, array of the semiconductor gas sensors and is installed on multicopter. The system was developed based on the commercially available DJI Matrix 100 platform. For data collection and communication with operator, the special compact computer (Intel Compute Stick) was installed onboard. The total weight of the system was 3.3 kg. The system allows the 15-minute flight and provides the remote access to the obtained data. The developed system can be effectively used for the detection of impurities in the air, ecology monitoring, detection of chemical warfare agents, and explosives, what is especially important in light of recent terroristic attacks. The capabilities of the system were tested on the several explosives such as trinitrotoluene and nitro powder. Copyright © 2017 John Wiley & Sons, Ltd.
Egypt`s first remotely controlled subsea completion -- A Gulf of Suez case history
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Hawary, A.; Hoffman, J.G.
1995-11-01
A case history of the Gulf of Suez Petroleum Company`s (GUPCO) first remotely controlled subsea completion is provided. The first completion was for well GS 373-2, a previously drilled and tested exploration well located in the south portion of the Gulf of Suez. Subsea technology was utilized to economically justify development of this one well marginal field which was discovered in 1978. Traditional methods proved to be too costly for development, therefore application of a low cost subsea tree was utilized to capture the resources. In the Gulf of Suez many fields have been discovered by have not been developedmore » due to low reserves. These marginal projects can have a profound impact on the revenue and shareholder value if any economic method is used to exploit these opportunities. Platform installation was not feasible due to reserve size, hence the well has remained abandoned until recently. Capturing the experience of Amoco in the Gulf of Mexico and in the Dutch North Sea, GUPCO was able to build a low cost subsea system which would allow for the economic development of the marginal fields discovered in the past. This paper presents a summarized look at subsea completion technology. The cost comparison of traditional development methods will be made, given the local cost structure in Egypt. The application of this technology has some limitations and constraints which will be discussed in the paper. Furthermore the actual field installation of Egypt`s first remotely controlled subsea tree will be summarized. Also included is a discussion on simple remote controls,and offshore installation operations.« less
Pak, JuGeon; Park, KeeHyun
2012-01-01
We propose a smart medication dispenser having a high degree of scalability and remote manageability. We construct the dispenser to have extensible hardware architecture for achieving scalability, and we install an agent program in it for achieving remote manageability. The dispenser operates as follows: when the real-time clock reaches the predetermined medication time and the user presses the dispense button at that time, the predetermined medication is dispensed from the medication dispensing tray (MDT). In the proposed dispenser, the medication for each patient is stored in an MDT. One smart medication dispenser contains mainly one MDT; however, the dispenser can be extended to include more MDTs in order to support multiple users using one dispenser. For remote management, the proposed dispenser transmits the medication status and the system configurations to the monitoring server. In the case of a specific event such as a shortage of medication, memory overload, software error, or non-adherence, the event is transmitted immediately. All these operations are performed automatically without the intervention of patients, through the agent program installed in the dispenser. Results of implementation and verification show that the proposed dispenser operates normally and performs the management operations from the medication monitoring server suitably.
NASA Astrophysics Data System (ADS)
Bazhin, V. Yu; Danilov, I. V.; Petrov, P. A.
2018-05-01
During the casting of light alloys and ligatures based on aluminum and magnesium, problems of the qualitative distribution of the metal and its crystallization in the mold arise. To monitor the defects of molds on the casting conveyor, a camera with a resolution of 780 x 580 pixels and a shooting rate of 75 frames per second was selected. Images of molds from casting machines were used as input data for neural network algorithm. On the preparation of a digital database and its analytical evaluation stage, the architecture of the convolutional neural network was chosen for the algorithm. The information flow from the local controller is transferred to the OPC server and then to the SCADA system of foundry. After the training, accuracy of neural network defect recognition was about 95.1% on a validation split. After the training, weight coefficients of the neural network were used on testing split and algorithm had identical accuracy with validation images. The proposed technical solutions make it possible to increase the efficiency of the automated process control system in the foundry by expanding the digital database.
Experimental and analytical study of water pipe's rupture for damage identification purposes
NASA Astrophysics Data System (ADS)
Papakonstantinou, Konstantinos G.; Shinozuka, Masanobu; Beikae, Mohsen
2011-04-01
A malfunction, local damage or sudden pipe break of a pipeline system can trigger significant flow variations. As shown in the paper, pressure variations and pipe vibrations are two strongly correlated parameters. A sudden change in the flow velocity and pressure of a pipeline system can induce pipe vibrations. Thus, based on acceleration data, a rapid detection and localization of a possible damage may be carried out by inexpensive, nonintrusive monitoring techniques. To illustrate this approach, an experiment on a single pipe was conducted in the laboratory. Pressure gauges and accelerometers were installed and their correlation was checked during an artificially created transient flow. The experimental findings validated the correlation between the parameters. The interaction between pressure variations and pipe vibrations was also theoretically justified. The developed analytical model explains the connection among flow pressure, velocity, pressure wave propagation and pipe vibration. The proposed method provides a rapid, efficient and practical way to identify and locate sudden failures of a pipeline system and sets firm foundations for the development and implementation of an advanced, new generation Supervisory Control and Data Acquisition (SCADA) system for continuous health monitoring of pipe networks.
NASA Astrophysics Data System (ADS)
Ginsberg, Mark D.; Smith, Eddy D.; VanBlaricum, Vicki; Hock, Vincent F.; Kroll, Dan; Russell, Kevin J.
2010-04-01
Both real events and models have proven that drinking water systems are vulnerable to deliberate and/or accidental contamination. Additionally, homeland security initiatives and modeling efforts have determined that it is relatively easy to orchestrate the contamination of potable water supplies. Such contamination can be accomplished with classic and non-traditional chemical agents, toxic industrial chemicals (TICs), and/or toxic industrial materials (TIMs). Subsequent research and testing has developed a proven network for detection and response to these threats. The method uses offthe- shelf, broad-spectrum analytical instruments coupled with advanced interpretive algorithms. The system detects and characterizes any backflow events involving toxic contaminants by employing unique chemical signature (fingerprint) response data. This instrumentation has been certified by the Office of Homeland Security for detecting deliberate and/or accidental contamination of critical water infrastructure. The system involves integration of several mature technologies (sensors, SCADA, dynamic models, and the HACH HST Guardian Blue instrumentation) into a complete, real-time, management system that also can be used to address other water distribution concerns, such as corrosion. This paper summarizes the reasons and results for installing such a distribution-based detection and protection system.
Wind Turbine Failures - Tackling current Problems in Failure Data Analysis
NASA Astrophysics Data System (ADS)
Reder, M. D.; Gonzalez, E.; Melero, J. J.
2016-09-01
The wind industry has been growing significantly over the past decades, resulting in a remarkable increase in installed wind power capacity. Turbine technologies are rapidly evolving in terms of complexity and size, and there is an urgent need for cost effective operation and maintenance (O&M) strategies. Especially unplanned downtime represents one of the main cost drivers of a modern wind farm. Here, reliability and failure prediction models can enable operators to apply preventive O&M strategies rather than corrective actions. In order to develop these models, the failure rates and downtimes of wind turbine (WT) components have to be understood profoundly. This paper is focused on tackling three of the main issues related to WT failure analyses. These are, the non-uniform data treatment, the scarcity of available failure analyses, and the lack of investigation on alternative data sources. For this, a modernised form of an existing WT taxonomy is introduced. Additionally, an extensive analysis of historical failure and downtime data of more than 4300 turbines is presented. Finally, the possibilities to encounter the lack of available failure data by complementing historical databases with Supervisory Control and Data Acquisition (SCADA) alarms are evaluated.
Experience of 12 kA / 16 V SMPS during the HTS Current Leads Test
NASA Astrophysics Data System (ADS)
Panchal, P.; Christian, D.; Panchal, R.; Sonara, D.; Purwar, G.; Garg, A.; Nimavat, H.; Singh, G.; Patel, J.; Tanna, V.; Pradhan, S.
2017-04-01
As a part of up gradation plans in SST-1 Tokamak, one pair of 3.3 kA rated prototype hybrid current leads were developed using Di-BSCCO as High Temperature Superconductors (HTS) and the copper heat exchanger. In order to validate the manufacturing procedure prior to go for series production of such current leads, it was recommended to test these current leads using dedicated and very reliable DC switch mode power supply (SMPS). As part of test facility, 12 kA, 16 VDC programmable SMPS was successfully installed, commissioned and tested. This power supply has special features such as modularity, N+1 redundancy, very low ripple voltage, precise current measurements with Direct Current Current Transformer, CC/CV modes with auto-crossover and auto-sequence programming. As a part of acceptance of this converter, A 5.8 mΩ water-cooled resistive dummy load and PLC based SCADA system is designed, developed for commissioning of power supply. The same power supply was used for the testing of the prototype HTS current leads. The paper describes the salient features and experience of state-of-art of power supply and results obtained from this converter during the HTS current leads test.
Commissioning and Operational Experience with 1 kW Class Helium Refrigerator/Liquefier for SST-1
NASA Astrophysics Data System (ADS)
Dhard, C. P.; Sarkar, B.; Misra, Ruchi; Sahu, A. K.; Tanna, V. L.; Tank, J.; Panchal, P.; Patel, J. C.; Phadke, G. D.; Saxena, Y. C.
2004-06-01
The helium refrigerator/liquefier (R/L) for the Steady State Super conducting Tokamak (SST-1) has been developed with very stringent specifications for the different operational modes. The total refrigeration capacity is 650 W at 4.5 K and liquefaction capacity of 200 l/h. A cold circulation pump is used for the forced flow cooling of 300 g/s supercritical helium (SHe) for the magnet system (SCMS). The R/L has been designed also to absorb a 200 W transient heat load of the SCMS. The plant consists of a compressor station, oil removal system, on-line purifier, Main Control Dewar (MCD) with associated heat exchangers, cold circulation pump and warm gas management system. An Integrated Flow Control and Distribution System (IFDCS) has been designed, fabricated and installed for distribution of SHe in the toroidal and poloidal field coils as well as liquid helium for cooling of 10 pairs of current leads. A SCADA based control system has been designed using PLC for R/L as well as IFDCS. The R/L has been commissioned and required parameters were achieved confirming to the process. All the test results and commissioning experiences are discussed in this paper.
Pavlicek, W; Zavalkovskiy, B; Eversman, W G
1999-05-01
Mayo Clinic Scottsdale (MCS) is a busy outpatient facility (150,000 examinations per year) connected via asynchronous transfer mode (ATM; OC-3 155 MB/s) to a new Mayo Clinic Hospital (178 beds) located more than 12 miles distant. A primary care facility staffed by radiology lies roughly halfway between the hospital and clinic connected to both. Installed at each of the three locations is a high-speed star topology image network providing direct fiber connection (160 MB/s) from the local image storage unit (ISU) to the local radiology and clinical workstations. The clinic has 22 workstations in its star, the hospital has 13, and the primary care practice has two. In response to Mayo's request for a seamless service among the three locations, the vendor (GE Medical Systems, Milwaukee, WI) provided enhanced connectivity capability in a two-step process. First, a transfer gateway (TGW) was installed, tested, and implemented to provide the needed communication of the examinations generated at the three sites. Any examinations generated at either the hospital or the primary care facility (specified as the remote stars) automatically transfer their images to the ISU at the clinic. Permanent storage (Kodak optical jukebox, Rochester, NY) is only connected to the hub (Clinic) star. Thus, the hub ISU is provided with a copy of all examinations, while the two remote ISUs maintain local exams. Prefetching from the archive is intelligently accomplished during the off hours only to the hub star, thus providing the remote stars with network dependent access to comparison images. Image transfer is possible via remote log-on. The second step was the installation of an image transfer server (ITS) to replace the slower Digital Imaging and Communications in Medicine (DICOM)-based TGW, and a central higher performance database to replace the multiple database environment. This topology provides an enterprise view of the images at the three locations, while maintaining the high-speed performance of the local star connection to what is now called the short-term storage (STS). Performance was measured and 25 chest examinations (17 MB each) transferred in just over 4 minutes. Integration of the radiology information management system (RIMS) was modified to provide location-specific report and examination interfaces, thereby allowing local filtering of the worklist to remote and near real-time consultation, and remote examination monitoring of modalities are addressed with this technologic approach. The installation of the single database ITS environment has occurred for testing prior to implementation.
Perrin installs the MBS to the Mobile Transporter railcar during STS-111 UF-2 EVA 2
2002-06-12
STS111-E-5238 (11 June 2002) --- Astronaut Philippe Perrin, STS-111 mission specialist, works on the installation of the Mobile Remote Servicer Base System (MBS) on the International Space Stations (ISS) railcar, the Mobile Transporter, during the second scheduled session of extravehicular activity (EVA) for the STS-111 mission. Perrin represents CNES, the French Space Agency.
Perrin installs the MBS to the Mobile Transporter railcar during STS-111 UF-2 EVA 2
2002-06-12
STS111-E-5240 (11 June 2002) --- Astronaut Philippe Perrin, STS-111 mission specialist, works on the installation of the Mobile Remote Servicer Base System (MBS) on the International Space Stations (ISS) railcar, the Mobile Transporter, during the second scheduled session of extravehicular activity (EVA) for the STS-111 mission. Perrin represents CNES, the French Space Agency.
RivGen, Igiugig Deployment, Control System Specifications and Models
Forbush, Dominic; Cavagnaro, Robert J.; Guerra, Maricarmen; Donegan, James; McEntee, Jarlath; Thomson, Jim; Polagye, Brian; Fabien, Brian; Kilcher, Levi
2016-03-21
Control System simulation models, case studies, and processing codes for analyzing field data. Raw data files included from VFD and SCADA. MatLab and Simulink are required to open some data files and all model files.
Combating Memory Corruption Attacks On Scada Devices
NASA Astrophysics Data System (ADS)
Bellettini, Carlo; Rrushi, Julian
Memory corruption attacks on SCADA devices can cause significant disruptions to control systems and the industrial processes they operate. However, despite the presence of numerous memory corruption vulnerabilities, few, if any, techniques have been proposed for addressing the vulnerabilities or for combating memory corruption attacks. This paper describes a technique for defending against memory corruption attacks by enforcing logical boundaries between potentially hostile data and safe data in protected processes. The technique encrypts all input data using random keys; the encrypted data is stored in main memory and is decrypted according to the principle of least privilege just before it is processed by the CPU. The defensive technique affects the precision with which attackers can corrupt control data and pure data, protecting against code injection and arc injection attacks, and alleviating problems posed by the incomparability of mitigation techniques. An experimental evaluation involving the popular Modbus protocol demonstrates the feasibility and efficiency of the defensive technique.
Object-Oriented Technology-Based Software Library for Operations of Water Reclamation Centers
NASA Astrophysics Data System (ADS)
Otani, Tetsuo; Shimada, Takehiro; Yoshida, Norio; Abe, Wataru
SCADA systems in water reclamation centers have been constructed based on hardware and software that each manufacturer produced according to their design. Even though this approach used to be effective to realize real-time and reliable execution, it is an obstacle to cost reduction about system construction and maintenance. A promising solution to address the problem is to set specifications that can be used commonly. In terms of software, information model approach has been adopted in SCADA systems in other field, such as telecommunications and power systems. An information model is a piece of software specification that describes a physical or logical object to be monitored. In this paper, we propose information models for operations of water reclamation centers, which have not ever existed. In addition, we show the feasibility of the information model in terms of common use and processing performance.
Installation and operation of a large scale RAPS system in Peru
NASA Astrophysics Data System (ADS)
Cole, J. F.
In 1997, International Lead Zinc Research Organization Inc. (ILZRO), Solar Energy Industries Association (SEIA), and the Ministry of Energy and Mines (MEM) of Peru signed a Memorandum of Understanding to facilitate the installation of hybrid remote area power supply (RAPS) systems in the Amazon region of Peru. Many remote villages in this vast region have either no or limited electricity supplied by diesel generators running a few hours per day. Subsequently, ILZRO sponsored the engineering design of the hybrid RAPS system and SEIA supported a socio-economic study to determine the sustainability of such systems and the locations for pilot installations. In mid-1998, the Peruvian government approved the design of the system. ILZRO then began efforts to obtain governmental and inter-governmental funding to supplement its own funds to underwrite the cost of manufacture and installation of the systems in two villages in the Amazon region. Additional major funding has been received from the Global Environmental Facility (GEF) administered by the United Nations Development Program (UNDP) and from the Common Fund for Commodities (CFC). Funds have also been received from the US Department of Energy, the International Greenhouse Partnership (Australia) and the Peruvian government. The RAPS system consists of modules designed to provide 150 kW h per day of utility grade ac electricity over a 24 h period. Each module contains a diesel generator, battery bank using heavy-duty 2 V VRLA GEL batteries, a battery charger, a photovoltaic array and an ac/dc inverter. The batteries and electrical components are housed in modified shipping containers. The modules can be installed with a new generator or retrofitted to an existing generator. The charging and discharging regime of the batteries has been recommended by a study carried out by CSIRO, which has simulated the RAPS operation. The system will employ a partial-state-of-charge (PSOC) regime in order to optimize the life of the batteries, which have a projected life of 8-10 years. A remote monitoring system will consist of a satellite link between each of the remote area power systems and one or more central hosts. The system operator will be able to obtain actual operational status of the system and will be able to change set points and to force operation of certain functions in order to test the system. Preliminary cost analyses indicate that such RAPS systems are more economically attractive to provide electricity to remote villages than other alternatives, including 24 h diesel generation and grid extension. The past 5 years have provided a number of lessons learned, particularly related to dealing with government agencies in a developing country, overcoming logistical problems such as shipping long distances and dealing with difficult climate and terrain. Despite difficulties encountered, the promise of RAPS systems as a rapidly growing market for lead-acid batteries appears to be bright given the demand for sustainable remote electrification.
Use of remote sensing for land use policy formulation
NASA Technical Reports Server (NTRS)
1981-01-01
Progress in studies for using remotely sensed data for assessing crop stress and in crop estimation is reported. The estimation of acreage of small forested areas in the southern lower peninsula of Michigan using LANDSAT data is evaluated. Damage to small grains caused by the cereal leaf beetle was assessed through remote sensing. The remote detection of X-disease of peach and cherry trees and of fire blight of pear and apple trees was investigated. The reliability of improving on standard methods of crop production estimation was demonstrated. Areas of virus infestation in vineyards and blueberry fields in western and southwestern Michigan were identified. The installation and systems integration of a microcomputer system for processing and making available remotely sensed data are described.
Variable acuity remote viewing system flight demonstration
NASA Technical Reports Server (NTRS)
Fisher, R. W.
1983-01-01
The Variable Acuity Remote Viewing System (VARVS), originally developed under contract to the Navy (ONR) as a laboratory brassboard, was modified for flight demonstration. The VARVS system was originally conceived as a technique which could circumvent the acuity/field of view/bandwidth tradeoffs that exists in remote viewing to provide a nearly eye limited display in both field of view (160 deg) and resolution (2 min arc) while utilizing conventional TV sensing, transmission, and display equipment. The modifications for flight demonstration consisted of modifying the sensor so it could be installed and flow in a Piper PA20 aircraft, equipped for remote control and modifying the display equipment so it could be integrated with the NASA Research RPB (RPRV) remote control cockpit.
NASA Technical Reports Server (NTRS)
Delombard, R.
1984-01-01
A photovoltaic power system which will be installed at a remote location in Indonesia to provide power for a satellite Earth station and a classroom for video and audio teleconferences are described. The Earth station may also provide telephone service to a nearby village. The use of satellite communications for development assistance applications and the suitability of a hybrid photovoltaic engine generator power system for remote satellite Earth stations are demonstrated. The Indonesian rural satellite project is discussed and the photovoltaic power system is described.
ERIC Educational Resources Information Center
Buckland, Lawrence F.; Madden, Mary
From experimental work performed, and reported upon in this document, it is concluded that converting the New York State Library (NYSL) shelf list sample to machine readable form, and searching this shelf list using a remote access catalog are technically sound concepts though the capital costs of data conversion and system installation will be…
Radiator on S0 truss after remote deployment
2002-10-14
STS112-E-05563 (14 October 2002) --- View of one of the radiators on the newly installed Starboard One (S1) Truss which was remotely deployed to verify the connections established on the first spacewalk for the STS-112 mission. Its extended length was 75 feet with each of the eight panels being 11 feet wide. The cooling systems will not formally be activated until next year.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meador, Richard J.; Hatley, Darrel D.
2004-06-01
PNNL DSOM technology coordinates efficient steam plant operation with EMCS and SCADA systems, providing generation support and automated load shedding to meet peak demand limits saving over $1M in two years.
Design description report for a photovoltaic power system for a remote satellite earth terminal
NASA Technical Reports Server (NTRS)
Marshall, N. A.; Naff, G. J.
1987-01-01
A photovoltaic (PV) power system has been installed as an adjunct to an agricultural school at Wawatobi on the large northern island of the Republic of Indonesia. Its purpose is to provide power for a satellite earth station and a classroom. The renewable energy developed supports the video and audio teleconferencing systems as well as the facility at large. The ground station may later be used to provide telephone service. The installation was made in support of the Agency for International Development's Rural Satellite Program, whose purpose is to demonstrate the use of satellite communications for rural development assistance applications. The objective of this particular PV power system is to demonstrate the suitability of a hybrid PV engine-generator configuration for remote satellite earth stations.
Passive Seismic Monitoring for Rockfall at Yucca Mountain: Concept Tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, J; Twilley, K; Murvosh, H
2003-03-03
For the purpose of proof-testing a system intended to remotely monitor rockfall inside a potential radioactive waste repository at Yucca Mountain, a system of seismic sub-arrays will be deployed and tested on the surface of the mountain. The goal is to identify and locate rockfall events remotely using automated data collecting and processing techniques. We install seismometers on the ground surface, generate seismic energy to simulate rockfall in underground space beneath the array, and interpret the surface response to discriminate and locate the event. Data will be analyzed using matched-field processing, a generalized beam forming method for localizing discrete signals.more » Software is being developed to facilitate the processing. To date, a three-component sub-array has been installed and successfully tested.« less
2007-02-16
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers prepare the Remote Manipulator System, or robotic arm, for installation on the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
47 CFR 74.12 - Notification of filing of applications.
Code of Federal Regulations, 2010 CFR
2010-10-01
....1030 “Notification concerning interference to Radio Astronomy, Research, and Receiving Installations... remote pickup stations (subpart D). (b) TV pickup stations (subpart F). (c) Low power auxiliary stations...
47 CFR 74.533 - Remote control and unattended operation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... EXPERIMENTAL RADIO, AUXILIARY, SPECIAL BROADCAST AND OTHER PROGRAM DISTRIBUTIONAL SERVICES Aural Broadcast... designed, installed, and protected so that the transmitter can only be activated or controlled by persons...
47 CFR 74.533 - Remote control and unattended operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... EXPERIMENTAL RADIO, AUXILIARY, SPECIAL BROADCAST AND OTHER PROGRAM DISTRIBUTIONAL SERVICES Aural Broadcast... designed, installed, and protected so that the transmitter can only be activated or controlled by persons...
47 CFR 74.533 - Remote control and unattended operation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... EXPERIMENTAL RADIO, AUXILIARY, SPECIAL BROADCAST AND OTHER PROGRAM DISTRIBUTIONAL SERVICES Aural Broadcast... designed, installed, and protected so that the transmitter can only be activated or controlled by persons...
VALIDATING the Accuracy of Sighten's Automated Shading Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solar companies - including installers, financiers, and distributors - leverage Sighten software to deliver accurate shading calculations and solar proposals. Sighten recently partnered with Google Project Sunroof to provide automated remote shading analysis directly within the Sighten platform. The National Renewable Energy Laboratory (NREL), in partnership with Sighten, independently verified the accuracy of Sighten's remote-shading solar access values (SAVs) on an annual basis for locations in Los Angeles, California, and Denver, Colorado.
The Installation of Satellite Modems on SEIS-UK Supported Remote Seismic Deployments
NASA Astrophysics Data System (ADS)
Horleston, A. C.; Brisbourne, A.; Hawthorn, D.
2006-12-01
SEIS-UK, as the UK's NERC funded national seismic equipment facility, is frequently involved in large, often remote, temporary seismic networks (running for up to 2 years). Up till now all these deployments have been managed solely by on-site maintenance but now SEIS-UK is investing in a number of satellite modems. The Michrosat 2400 OEM Modems, provided by Wireless Innovations Ltd, will be integrated within Guralp DCM data-logger units and will be used to provide regular state-of-health reports from remote networks. They will also provide the user the facility to communicate with the deployed systems, apply configuration changes and request system re-boots. This should lead to less instrument down-time and allow for more focussed site visits and thus, hopefully, reduce the cost (and servicing time) of remote installations. The Michrosat Modems are relatively low-powered and draw a maximum current of 2.5A (at 4.4v) for a few microseconds when initialising a call, dropping to bursts of approximately 1A when transmitting. This makes them ideally suited to temporary deployments relying on solar charged battery power. We will present examples of the configuration and typical deployment of the modems and the types of data transmitted.
Hydraulic jet pumping in a remote location
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tjondrodiputro, B.; Gaul, R.B.; Gower, G.H.
1986-12-01
Hydraulic jet pumping equipment was installed in six Sembakung field (N.E. Kalimantan) wells by Atlantic Richfield Indonesia Inc., for Pertamina during 1983, and this article presents the experience acquired in the process of installing and operating this type of artificial-lift equipment in a remote location. Characteristics of the wells and equipment are reviewed, and possible future installations in similar circumstances are discussed. Sembakung oil field, discovered in late 1975, contained 17 wells after complete development. By 1983, some were flowing weakly and several zones were dead, indicating the need for some form of artificial lift. The choice of artificial liftmore » methods was limited by the lack of gas-lift gas, absence of a field-wide power distribution system, unavailability of a rod pumping well servicing unit, and lack of roads in the marshy environment. Thus, hydraulic (free-type) jet pumping was selected as the optimum technique. Jet pumps were installed in six of 17 wells in the field at the end of 1983. Downhole equipment was installed using a heli-rig, and all surface equipment was delivered to location using helicopters. Since startup, some operating problems occurred, but they have all been resolved. Well pumping rates range from 340 to 650 bpd gross, with 0 to 50% BSandW. The jet-pumped wells produced satisfactorily through July 1984, at which time operations were turned over to Pertamina Unit IV at the conclusion of the contractual term.« less
Industrial Control System Process-Oriented Intrusion Detection (iPoid) Algorithm
2016-08-01
inspection rules using an intrusion-detection system (IDS) sensor, a simulated Programmable Logic Controller (PLC), and a Modbus client operating...operating system PLC Programmable Logic Controller SCADA supervisory control and data acquisition SIGHUP signal hangup SPAN Switched Port Analyzer
Evaluation of the Aurora Application Shade Measurement Accuracy
DOE Office of Scientific and Technical Information (OSTI.GOV)
2015-12-01
Aurora is an integrated, Web-based application that helps solar installers perform sales, engineering design, and financial analysis. One of Aurora's key features is its high-resolution remote shading analysis.
Cryogenic system for the ArTeMiS large sub millimeter camera
NASA Astrophysics Data System (ADS)
Ercolani, E.; Relland, J.; Clerc, L.; Duband, L.; Jourdan, T.; Talvard, M.; Le Pennec, J.; Martignac, J.; Visticot, F.
2014-07-01
A new photonic camera has been developed in the framework of the ArTéMis project (Bolometers architecture for large field of view ground based telescopes in the sub-millimeter). This camera scans the sky in the sub-millimeter range at simultaneously three different wavelengths, namely 200 μm, 350 μm, 450 μm, and is installed inside the APEX telescope located at 5100m above sea level in Chile. Bolometric detectors cooled to 300 mK are used in the camera, which is integrated in an original cryostat developed at the low temperature laboratory (SBT) of the INAC institut. This cryostat contains filters, optics, mirrors and detectors which have to be implemented according to mass, size and stiffness requirements. As a result the cryostat exhibits an unusual geometry. The inner structure of the cryostat is a 40 K plate which acts as an optical bench and is bound to the external vessel through two hexapods, one fixed and the other one mobile thanks to a ball bearing. Once the cryostat is cold, this characteristic enabled all the different elements to be aligned with the optical axis. The cryogenic chain is built around a pulse tube cooler (40 K and 4 K) coupled to a double stage helium sorption cooler (300 mK). The cryogenic and vacuum processes are managed by a Siemens PLC and all the data are showed and stored on a CEA SCADA system. This paper describes the mechanical and thermal design of the cryostat, its command control, and the first thermal laboratory tests. This work was carried out in collaboration with the Astrophysics laboratory SAp of the IRFU institut. SAp and SBT have installed the camera in July 2013 inside the Cassegrain cabin of APEX.
Emergency Medicine in Remote Regions.
Renouf, Tia; Pollard, Megan
2016-09-09
Rural and remote places like Sable Island (Nova Scotia) or François (Newfoundland) pose a challenge in delivering both health care and appropriate education that today's learners need to practice in a rural setting. This education can be difficult to deliver to students far from academic centers. This is especially true for learners and practitioners at offshore locations like ships, oil installations, or in the air when patients are transported via fixed wing aircraft or helicopter. The following editorial provides a snapshot of the setting and the challenges faced while working as a physician on a ship, in remote regions.
Suzuki, Keishiro; Hirasawa, Yukinori; Yaegashi, Yuji; Miyamoto, Hideki; Shirato, Hiroki
2009-01-01
We developed a web-based, remote radiation treatment planning system which allowed staff at an affiliated hospital to obtain support from a fully staffed central institution. Network security was based on a firewall and a virtual private network (VPN). Client computers were installed at a cancer centre, at a university hospital and at a staff home. We remotely operated the treatment planning computer using the Remote Desktop function built in to the Windows operating system. Except for the initial setup of the VPN router, no special knowledge was needed to operate the remote radiation treatment planning system. There was a time lag that seemed to depend on the volume of data traffic on the Internet, but it did not affect smooth operation. The initial cost and running cost of the system were reasonable.
Translations on Environmental Quality, Number 148
1977-10-03
Article 9. Designs for gas filtering installations must include the proper control and automation facilities as per articles 16 and 17. Article 10...mandatorily equipped with: 1. Locking armature at the gas entrance and exit with manual or remote control flanges for the installation of end-caps in...instruments shall be mounted on the control panel of the gas filtering system or the control panel for the technological process. Article 17. (1) The gas
2006-12-12
S116-E-05764 (11 Dec. 2006) --- The International Space Station's Canadarm2 moves toward the station's new P5 truss section for a hand-off from Space Shuttle Discovery's Remote Manipulator System (RMS) robotic arm.
2006-12-12
S116-E-05765 (11 Dec. 2006) --- The International Space Station's Canadarm2 moves toward the station's new P5 truss section for a hand-off from Space Shuttle Discovery's Remote Manipulator System (RMS) robotic arm.
24 CFR 3280.609 - Water distribution systems.
Code of Federal Regulations, 2010 CFR
2010-04-01
... and temperature relief valve installed for this purpose shall have the temperature sensing element...) Size of branch. Start at the most remote outlet on any branch of the hot or cold water piping and...
Mobile lidar system for environmental monitoring
NASA Astrophysics Data System (ADS)
Zhao, Guangyu; Lian, Ming; Li, Yiyun; Duan, Zheng; Zhu, Shiming; Svanberg, Sune
2018-04-01
A versatile mobile remote sensing system for multidisciplinary environmental monitoring tasks on the Chinese scene is described. The system includes a 20 Hz Nd:YAG laser-pumped dye laser, optical transmitting/receiving systems with a 30 cm and a 40 cm Newtonian telescope, and electronics, all integrated in a laboratory, installed on a Jiefang truck. Results from field experiments on atomic mercury DIAL mapping and remote laser-induced fluorescence and break-down spectroscopy are given.
Fiberglass distribution poles: A case study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, M.F.; Hosford, G.S.; Boozer, J.F. III
1995-01-01
This paper addresses the design considerations and manufacturing techniques along with mechanical test results of fiberglass reinforced composite (FRC) primary distribution poles. With it`s light weight, and virtually no maintenance it offers a viable alternative for use in remote and inaccessible locations. This paper also discusses a case study where seventy five FRC primary distribution poles have been installed on a distribution system in a remote area accessible only by foot and helicopter.
Refurbishment and Automation of the Thermal/Vacuum Facilities at the Goddard Space Flight Center
NASA Technical Reports Server (NTRS)
Donohue, John T.; Johnson, Chris; Ogden, Rick; Sushon, Janet
1998-01-01
The thermal/vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the 11 facilities, currently 10 of the systems are scheduled for refurbishment and/or replacement as part of a 5-year implementation. Expected return on investment includes the reduction in test schedules, improvements in the safety of facility operations, reduction in the complexity of a test and the reduction in personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering and for the automation of thermal/vacuum facilities and thermal/vacuum tests. Automation of the thermal/vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs) and the use of Supervisory Control and Data Acquisition (SCADA) systems. These components allow the computer control and automation of mechanical components such as valves and pumps. In some cases, the chamber and chamber shroud require complete replacement while others require only mechanical component retrofit or replacement. The project of refurbishment and automation began in 1996 and has resulted in the computer control of one Facility (Facility #225) and the integration of electronically controlled devices and PLCs within several other facilities. Facility 225 has been successfully controlled by PLC and SCADA for over one year. Insignificant anomalies have occurred and were resolved with minimal impact to testing and operations. The amount of work remaining to be performed will occur over the next four to five years. Fiscal year 1998 includes the complete refurbishment of one facility, computer control of the thermal systems in two facilities, implementation of SCADA and PLC systems to support multiple facilities and the implementation of a Database server to allow efficient test management and data analysis.
Remote Neural Pendants In A Welding-Control System
NASA Technical Reports Server (NTRS)
Venable, Richard A.; Bucher, Joseph H.
1995-01-01
Neural network integrated circuits enhance functionalities of both remote terminals (called "pendants") and communication links, without necessitating installation of additional wires in links. Makes possible to incorporate many features into pendant, including real-time display of critical welding parameters and other process information, capability for communication between technician at pendant and host computer or technician elsewhere in system, and switches and potentiometers through which technician at pendant exerts remote control over such critical aspects of welding process as current, voltage, rate of travel, flow of gas, starting, and stopping. Other potential manufacturing applications include control of spray coating and of curing of composite materials. Potential nonmanufacturing uses include remote control of heating, air conditioning, and lighting in electrically noisy and otherwise hostile environments.
NASA Astrophysics Data System (ADS)
Mittelmeier, N.; Blodau, T.; Steinfeld, G.; Rott, A.; Kühn, M.
2016-09-01
Atmospheric conditions have a clear influence on wake effects. Stability classification is usually based on wind speed, turbulence intensity, shear and temperature gradients measured partly at met masts, buoys or LiDARs. The objective of this paper is to find a classification for stability based on wind turbine Supervisory Control and Data Acquisition (SCADA) measurements in order to fit engineering wake models better to the current ambient conditions. Two offshore wind farms with met masts have been used to establish a correlation between met mast stability classification and new aggregated statistical signals based on multiple measurement devices. The significance of these new signals on power production is demonstrated for two wind farms with met masts and validated against data from one further wind farm without a met mast. We found a good correlation between the standard deviation of active power divided by the average power of wind turbines in free flow with the ambient turbulence intensity when the wind turbines were operating in partial load.
47 CFR 78.51 - Remote control operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... necessary to insure proper operation. (4) The control circuits shall be so designed and installed that short circuits, open circuits, other line faults, or any other cause which would result in loss of control of the...
33 CFR 19.15 - Permits for commercial vessels handling explosives at military installations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... no quantitative restrictions, based on considerations of isolation and remoteness, shall be required... from the Coast Guard for such operations with respect to quantitative or other restrictions imposed by...
33 CFR 19.15 - Permits for commercial vessels handling explosives at military installations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... no quantitative restrictions, based on considerations of isolation and remoteness, shall be required... from the Coast Guard for such operations with respect to quantitative or other restrictions imposed by...
33 CFR 19.15 - Permits for commercial vessels handling explosives at military installations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... no quantitative restrictions, based on considerations of isolation and remoteness, shall be required... from the Coast Guard for such operations with respect to quantitative or other restrictions imposed by...
33 CFR 19.15 - Permits for commercial vessels handling explosives at military installations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... no quantitative restrictions, based on considerations of isolation and remoteness, shall be required... from the Coast Guard for such operations with respect to quantitative or other restrictions imposed by...
33 CFR 19.15 - Permits for commercial vessels handling explosives at military installations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... no quantitative restrictions, based on considerations of isolation and remoteness, shall be required... from the Coast Guard for such operations with respect to quantitative or other restrictions imposed by...
Snow wetness measurements for melt forecasting
NASA Technical Reports Server (NTRS)
Linlor, W. I.; Clapp, F. D.; Meier, M. F.; Smith, J. L.
1975-01-01
A microwave technique for directly measuring snow pack wetness in remote installations is described. The technique, which uses satellite telemetry for data gathering, is based on the attenuation of a microwave beam in transmission through snow.
Installation Restoration Program. Phase 1. Records Search 15th ABW Satellite Installations, Hawaii
1984-09-01
Hickam POL Storage Facilities and Pipeline The POL storage facilities remotely located from Hickam Air Force Base (AFB...airfield with less activity than nearby Wheeler and Hickam Air Force Bases . Aircraft activity was significantly reduced in the late 1940’s and the...United States Air Force to conduct the Phase I Records Search at the 15th Air Base Wing 1-2 ES ENGINEERING-SCIENCE PHASE I PHASE 11 PHASE IV
2007-02-16
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to a hoisting device to prepare for installation to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers use a hoisting device to move the Remote Manipulator System, or robotic arm, toward the Japanese Experiment Module for installation and testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008.The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-16
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to a hoisting device to prepare for installation to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers use a hoisting device to move the Remote Manipulator System, or robotic arm, toward the Japanese Experiment Module for installation and testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008.The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-16
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to a hoisting device to prepare for installation to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
Radio Frequency Based Programmable Logic Controller Anomaly Detection
2013-09-01
include wireless radios, IEEE 802.15 Blue- tooth devices, cellular phones, and IEEE 802.11 WiFi networking devices. While wireless communication...MacKenzie, H. Shamoon Malware and SCADA Security What are the Im- pacts? . Technical Report, Tofino Security, Sep 2012. 61. Mateti,P. Hacking Techniques
Upgrade of U.S. EPA's Experimental Stream Facility Supervisory Control and Data Acquisition System
The Supervisory control and data acquisition (SCADA) system for the U.S. EPA’s Experimental Stream Facility (ESF) was upgraded using Camile hardware and software in 2015. The upgrade added additional hardwired connections, new wireless capabilities, and included a complete rewrit...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwabe, Paul
2016-02-11
This report provides a high-level examination of the potential economics of solar energy in rural Alaska across a geographically diverse sample of remote Alaska Native villages throughout the state. It analyzes at a high level what combination of diesel fuel prices, solar resource quality, and photovoltaic (PV) system costs could lead to an economically competitive moderate-scale PV installation at a remote village. The goal of this analysis is to provide a baseline economic assessment to highlight the possible economic opportunities for solar PV in rural Alaska for both the public and private sectors.
NASA Technical Reports Server (NTRS)
Perrier, R. (Principal Investigator)
1974-01-01
The author has identified the following significant results. The General Electric DCP has proven to be a versatile, rugged piece of hardware and has surpassed original expectation; it is very simple to use and does not require skilled staff for its use, installation, and operation. It is well suited for use in remote sites where no power is available. From this experience, it is concluded that the data collection system will be very useful in operating a network of hydrometeorological stations situated in sites remote from normal communication links.
GPS Remote Sensing Measurements Using Aerosonde UAV
NASA Technical Reports Server (NTRS)
Grant, Michael S.; Katzberg, Stephen J.; Lawrence, R. W.
2005-01-01
In February 2004, a NASA-Langley GPS Remote Sensor (GPSRS) unit was flown on an Aerosonde unmanned aerial vehicle (UAV) from the Wallops Flight Facility (WFF) in Virginia. Using direct and surface-reflected 1.575 GHz coarse acquisition (C/A) coded GPS signals, remote sensing measurements were obtained over land and portions of open water. The strength of the surface-reflected GPS signal is proportional to the amount of moisture in the surface, and is also influenced by surface roughness. Amplitude and other characteristics of the reflected signal allow an estimate of wind speed over open water. In this paper we provide a synopsis of the instrument accommodation requirements, installation procedures, and preliminary results from what is likely the first-ever flight of a GPS remote sensing instrument on a UAV. The correct operation of the GPSRS unit on this flight indicates that Aerosonde-like UAV's can serve as platforms for future GPS remote sensing science missions.
NASA Astrophysics Data System (ADS)
Rijal, Santosh
Various military training activities are conducted in more than 11.3 million hectares of land (> 5,500 training sites) in the United States (U.S.). These training activities directly and indirectly degrade the land. Land degradation can impede continuous military training. In order to sustain long term training missions and Army combat readiness, the environmental conditions of the military installations need to be carefully monitored and assessed. Furthermore, the National Environmental Policy Act of 1969 (NEPA) and the U.S. Army Regulation 200-2 require the DoD to minimize the environmental impacts of training and document the environmental consequences of their actions. To achieve these objectives, the Department of Army initiated an Integrated Training Area Management (ITAM) program to manage training lands through assessing their environmental requirements and establishing policies and procedures to achieve optimum, sustainable use of training lands. One of the programs under ITAM, Range and Training Land Assessment (RTLA) was established to collect field-based data for monitoring installation's environmental condition. Due to high cost and inefficiencies involved in the collection of field data, the RTLA program was stopped in several military installations. Therefore, there has been a strong need to develop an efficient and low cost remote sensing based methodology for assessing and monitoring land conditions of military installations. It is also important to make a long-term assessment of installation land condition for understanding cumulative impacts of continuous military training activities. Additionally, it is unclear that compared to non-military land condition, to what extent military training activities have led to the degradation of land condition for military installations. The first paper of this dissertation developed a soil erosion relevant and image derived cover factor (ICF) based on linear spectral mixture (LSM) analysis to assess and monitor the land condition of military land and compare it with non-military land. The results from this study can provide FR land managers with the information of the spatial variation and temporal trend of land condition in FR. Fort Riley land managers can also use this method for monitoring their land condition at a very low cost. This method can thus be applied to other military installations as well as non-military lands. Furthermore, one of the most significant environmental problems in military installations of the U.S. is the formation of gullies due to the intensive use of military vehicle. However, to our knowledge, no remote sensing based method has been developed and used to assess the detection of gullies in military installations. In the second paper of this dissertation, light detection and ranging (LiDAR) derived digital elevation model (DEM) of 2010 and WorldView-2 images of 2010 were used to quantify the gullies in FR. This method can be easily applied to assess gullies in non-military installations. On the other hand, modeling the land condition of military installation is critical to understand the spatial and temporal pattern of military training induced disturbance and land recovery. In the third paper, it was assumed that the military training induced disturbance was spatially auto-correlated and thus four regression models including i) linear stepwise regression (LSR) ii) logistic regression (LR), iii) geographically weighted linear regression (GWR), and iv) geographically weighted logistic regression (GWLR) were developed and compared using remote sensing image derived spectral variables for years 1990, 1997, 1998, 1999, and 2001. It was found that the spatial distribution of the military training disturbance was well demonstrated by all the regression models with higher intensities of military training disturbance in the northwest and central west parts of the installation. Compared to other regression models, GWR accurately estimated the land condition of FR. This result provided the applicability of using local variability based regression model to accurately predict land condition. Different plant communities of military installations respond differently to military training induced disturbance. The information of the spatial distribution of plant species in military installations is important to gain insight of the resilient capacity of the land following disturbances. For the purpose, in the fourth paper, hyperspectral in-situ data were collected from FR and KPBS in the summer of 2015 using a hyperspectral instrument. Principal component analysis (PCA) and band relative importance (BRI) were used to identify relative importance of each of the spectral bands. The results from this study provided useful information about the optimal wavelengths that help distinguish different plant species of FR and can be easily used with high resolution hyperspectral images for mapping the spatial distribution of the plant species. This information will be helpful for the sustainable management of the tallgrass prairie ecosystem. (Abstract shortened by ProQuest.).
DESI-Detection of early-season invasives (software-installation manual and user's guide version 1.0)
Kokaly, Raymond F.
2011-01-01
This report describes a software system for detecting early-season invasive plant species, such as cheatgrass. The report includes instructions for installing the software and serves as a user's guide in processing Landsat satellite remote sensing data to map the distributions of cheatgrass and other early-season invasive plants. The software was developed for application to the semi-arid regions of southern Utah; however, the detection parameters can be altered by the user for application to other areas.
Remote control of an impact demonstration vehicle
NASA Technical Reports Server (NTRS)
Harney, P. F.; Craft, J. B., Jr.; Johnson, R. G.
1985-01-01
Uplink and downlink telemetry systems were installed in a Boeing 720 aircraft that was remotely flown from Rogers Dry Lake at Edwards Air Force Base and impacted into a designated crash site on the lake bed. The controlled impact demonstration (CID) program was a joint venture by the National Aeronautics and Space Administration (NASA) and the Federal Aviation Administration (FAA) to test passenger survivability using antimisting kerosene (AMK) to inhibit postcrash fires, improve passenger seats and restraints, and improve fire-retardent materials. The uplink telemetry system was used to remotely control the aircraft and activate onboard systems from takeoff until after impact. Aircraft systems for remote control, aircraft structural response, passenger seat and restraint systems, and anthropomorphic dummy responses were recorded and displayed by the downlink stems. The instrumentation uplink and downlink systems are described.
Microcontroller-Based Experimental Setup and Experiments for SCADA Education
ERIC Educational Resources Information Center
Sahin, S.; Olmez, M.; Isler, Y.
2010-01-01
In the field of automation technology, research and development for industrial applications has increased rapidly in recent years. Therefore, industrial automation and control education is a very important element of the industrialization process in developing countries, such as Turkey, which needs to keep abreast for the latest developments in…
Application of Canal Automation at the Central Arizona Irrigation and Drainage District
USDA-ARS?s Scientific Manuscript database
The Central Arizona Irrigation and Drainage District (CAIDD) began delivering water to users in 1987. Although designed for automatic control, the system was run manually until a homemade SCADA (Supervisory Control and Data Acquisition) system was developed by a district employee. In 2002, problem...
7 CFR 1724.54 - Requirements for RUS approval of plans and specifications.
Code of Federal Regulations, 2012 CFR
2012-01-01
... specifications for transmission construction projects which are not based on RUS approved line design data or do...) Communications and control facilities. (1) This paragraph (g) covers microwave and powerline carrier communications systems, load control, and supervisory control and data acquisition (SCADA) systems. (2) The...
7 CFR 1724.54 - Requirements for RUS approval of plans and specifications.
Code of Federal Regulations, 2014 CFR
2014-01-01
... specifications for transmission construction projects which are not based on RUS approved line design data or do...) Communications and control facilities. (1) This paragraph (g) covers microwave and powerline carrier communications systems, load control, and supervisory control and data acquisition (SCADA) systems. (2) The...
7 CFR 1724.54 - Requirements for RUS approval of plans and specifications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... specifications for transmission construction projects which are not based on RUS approved line design data or do...) Communications and control facilities. (1) This paragraph (g) covers microwave and powerline carrier communications systems, load control, and supervisory control and data acquisition (SCADA) systems. (2) The...
Using SCADA Data, Field Studies, and Real-Time Modeling to Calibrate Flint's Hydraulic Model
EPA has been providing technical assistance to the City of Flint and the State of Michigan in response to the drinking water lead contamination incident. Responders quickly recognized the need for a water distribution system hydraulic model to provide insight on flow patterns an...
Towards Quantifying Programmable Logic Controller Resilience Against Intentional Exploits
2012-03-22
may improve the SCADA system’s resilience against DoS and man-in-the-middle ( MITM ) attacks. DoS attacks may be mitigated by using the redundant...paths available on the network links. MITM attacks may be mitigated by the data integrity checks associated with the middleware. Figure 4 illustrates
Lost Hills Field Trial - incorporating new technology for resevoir management
NASA Technical Reports Server (NTRS)
Fielding, E. J.; Brink, J. L.; Patzek, T. W.; Silin, D. B.
2002-01-01
This paper will discuss how Chevron U.S.A. Production Company is implementing a field trial that will use Supervisory Control and Data Acquisition (SCADA)on injection wells, in conjunction with satellite images to measure ground elevation changes, to perform real-time resevoir management in the Lost Hills Field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, G.A.
1998-03-11
This document defines the requirements applicable to the operation, maintenance and storage of the Supervisory Control and Data Acquisition System (SCADAS) and Control Network in support of the Light Duty Utility Arm (LDUA) operations.
46 CFR 56.50-25 - Safety and relief valve escape piping.
Code of Federal Regulations, 2010 CFR
2010-10-01
... supported and installed so that no stress is transmitted to the safety valve body. (c) Safety or relief... or to a remote position to minimize the hazardous effect of the escaping steam. (d) The effect of the...
Advanced component testing : Kaskasia handbrake test.
DOT National Transportation Integrated Search
2016-07-01
The evaluation of a prototype remote operation handbrake showed that it can be installed on a car with only minor modifications to connect the air. This prototype did not set the emergency during any of the testing performed. The operation of the pro...
The development of a tele-monitoring system for physiological parameters based on the B/S model.
Shuicai, Wu; Peijie, Jiang; Chunlan, Yang; Haomin, Li; Yanping, Bai
2010-01-01
The development of a new physiological multi-parameter remote monitoring system is based on the B/S model. The system consists of a server monitoring center, Internet network and PC-based multi-parameter monitors. Using the B/S model, the clients can browse web pages via the server monitoring center and download and install ActiveX controls. The physiological multi-parameters are collected, displayed and remotely transmitted. The experimental results show that the system is stable, reliable and operates in real time. The system is suitable for use in physiological multi-parameter remote monitoring for family and community healthcare. Copyright © 2010 Elsevier Ltd. All rights reserved.
Remote observing with the Nickel Telescope at Lick Observatory
NASA Astrophysics Data System (ADS)
Grigsby, Bryant; Chloros, Konstantinos; Gates, John; Deich, William T. S.; Gates, Elinor; Kibrick, Robert
2008-07-01
We describe a project to enable remote observing on the Nickel 1-meter Telescope at Lick Observatory. The purpose was to increase the subscription rate and create more economical means for graduate- and undergraduate students to observe with this telescope. The Nickel Telescope resides in a 125 year old dome on Mount Hamilton. Remote observers may work from any of the University of California (UC) remote observing facilities that have been created to support remote work at both Keck Observatory and Lick Observatory. The project included hardware and software upgrades to enable computer control of all equipment that must be operated by the astronomer; a remote observing architecture that is closely modeled on UCO/Lick's work to implement remote observing between UC campuses and Keck Observatory; new policies to ensure safety of Observatory staff and equipment, while ensuring that the telescope subsystems would be suitably configured for remote use; and new software to enforce the safety-related policies. The results increased the subscription rate from a few nights per month to nearly full subscription, and has spurred the installation of remote observing sites at more UC campuses. Thanks to the increased automation and computer control, local observing has also benefitted and is more efficient. Remote observing is now being implemented for the Shane 3- meter telescope.
Calvin-Rehoboth Robotic Twin Telescopes
NASA Astrophysics Data System (ADS)
Haarsma, D. B.; Molnar, L. A.; VanBaak, D. A.
2004-12-01
The astronomy program at Calvin College, like many small colleges, is limited by poor weather and light pollution at its midwestern campus and by limited free time on the part of its astronomy faculty. Nonetheless we believe direct access to the physical universe is key to the science education both of science majors and nonmajors. Recent advances in hardware and software for modest robotic telescopes have made it possible for colleges like ours to incorporate the use of a remote bservatory into our curriculum within typical financial and time constraints. In this poster we make our first report on the installation of two robotic telescopes (one on campus and one at a remote site in New Mexico) using largely off-the-shelf components. Students learn first with the local telescope in order to understand the equipment and procedures, but obtain the majority of their data with the remote telescope. Equipment development is done first with the local telescope, and then implemented on the remote telescope (where time spent in development is difficult). We received an NSF CCLI grant and matching college funds in the summer of 2002. The local telescope was installed in the spring of 2003, and the New Mexico telescope was ready for remote operation in January 2004. Our poster will describe our equipment choices, including a few components (such as an equipment rack for the back end of the telescope) which we designed ourselves. It will also detail classroom use of the equipment in its first two semesters by students at a range of levels. A copy of the poster and many additional details of the project are available on the Calvin observatory website, http://www.calvin.edu/observatory/.
Energy Systems Integration Laboratory | Energy Systems Integration Facility
systems test hub includes a Class 1, Division 2 space for performing tests of high-pressure hydrogen Laboratory offers the following capabilities. High-Pressure Hydrogen Systems The high-pressure hydrogen infrastructure. Key Infrastructure Robotic arm; high-pressure hydrogen; natural gas supply; standalone SCADA
2011-03-01
they can continue to leverage these capabilities (building Smart Grid infrastructure and providing Internet connectivity to every home ) while ensuring...21 Figure 9. Smart Grid Interoperability .............................................................................. 22 Figure 10. Smart ...Grid Integration .................................................................................... 24 Figure 11. National Smart Grid Initiatives
Power System Information Delivering System Based on Distributed Object
NASA Astrophysics Data System (ADS)
Tanaka, Tatsuji; Tsuchiya, Takehiko; Tamura, Setsuo; Seki, Tomomichi; Kubota, Kenji
In recent years, improvement in computer performance and development of computer network technology or the distributed information processing technology has a remarkable thing. Moreover, the deregulation is starting and will be spreading in the electric power industry in Japan. Consequently, power suppliers are required to supply low cost power with high quality services to customers. Corresponding to these movements the authors have been proposed SCOPE (System Configuration Of PowEr control system) architecture for distributed EMS/SCADA (Energy Management Systems / Supervisory Control and Data Acquisition) system based on distributed object technology, which offers the flexibility and expandability adapting those movements. In this paper, the authors introduce a prototype of the power system information delivering system, which was developed based on SCOPE architecture. This paper describes the architecture and the evaluation results of this prototype system. The power system information delivering system supplies useful power systems information such as electric power failures to the customers using Internet and distributed object technology. This system is new type of SCADA system which monitors failure of power transmission system and power distribution system with geographic information integrated way.
Algorithmic network monitoring for a modern water utility: a case study in Jerusalem.
Armon, A; Gutner, S; Rosenberg, A; Scolnicov, H
2011-01-01
We report on the design, deployment, and use of TaKaDu, a real-time algorithmic Water Infrastructure Monitoring solution, with a strong focus on water loss reduction and control. TaKaDu is provided as a commercial service to several customers worldwide. It has been in use at HaGihon, the Jerusalem utility, since mid 2009. Water utilities collect considerable real-time data from their networks, e.g. by means of a SCADA system and sensors measuring flow, pressure, and other data. We discuss how an algorithmic statistical solution analyses this wealth of raw data, flexibly using many types of input and picking out and reporting significant events and failures in the network. Of particular interest to most water utilities is the early detection capability for invisible leaks, also a means for preventing large visible bursts. The system also detects sensor and SCADA failures, various water quality issues, DMA boundary breaches, unrecorded or unintended network changes (like a valve or pump state change), and other events, including types unforeseen during system design. We discuss results from use at HaGihon, showing clear operational value.
Power Plant Model Validation Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
The PPMV is used to validate generator model using disturbance recordings. The PPMV tool contains a collection of power plant models and model validation studies, as well as disturbance recordings from a number of historic grid events. The user can import data from a new disturbance into the database, which converts PMU and SCADA data into GE PSLF format, and then run the tool to validate (or invalidate) the model for a specific power plant against its actual performance. The PNNL PPMV tool enables the automation of the process of power plant model validation using disturbance recordings. The tool usesmore » PMU and SCADA measurements as input information. The tool automatically adjusts all required EPCL scripts and interacts with GE PSLF in the batch mode. The main tool features includes: The tool interacts with GE PSLF; The tool uses GE PSLF Play-In Function for generator model validation; Database of projects (model validation studies); Database of the historic events; Database of the power plant; The tool has advanced visualization capabilities; and The tool automatically generates reports« less
A storage scheme for the real-time database supporting the on-line commitment
NASA Astrophysics Data System (ADS)
Dai, Hong-bin; Jing, Yu-jian; Wang, Hui
2013-07-01
The modern SCADA (Supervisory Control and Data acquisition) systems have been applied to various aspects of everyday life. As the time goes on, the requirements of the applications of the systems vary. Thus the data structure of the real-time database, which is the core of a SCADA system, often needs modification. As a result, the commitment consisting of a sequence of configuration operations modifying the data structure of the real-time database is performed from time to time. Though it is simple to perform the off-line commitment by first stopping and then restarting the system, during which all the data in the real-time database are reconstructed. It is much more preferred or in some cases even necessary to perform the on-line commitment, during which the real-time database can still provide real-time service and the system continues working normally. In this paper, a storage scheme of the data in the real-time database is proposed. It helps the real-time database support its on-line commitment, during which real-time service is still available.
Development of Solar Powered Irrigation System
NASA Astrophysics Data System (ADS)
Abdelkerim, A. I.; Sami Eusuf, M. M. R.; Salami, M. J. E.; Aibinu, A.; Eusuf, M. A.
2013-12-01
Development of a solar powered irrigation system has been discussed in this paper. This system would be SCADA-based and quite useful in areas where there is plenty of sunshine but insufficient water to carry out farming activities, such as rubber plantation, strawberry plantation, or any plantation, that requires frequent watering. The system is powered by solar system as a renewable energy which uses solar panel module to convert Sunlight into electricity. The development and implementation of an automated SCADA controlled system that uses PLC as a controller is significant to agricultural, oil and gas monitoring and control purpose purposes. In addition, the system is powered by an intelligent solar system in which solar panel targets the radiation from the Sun. Other than that, the solar system has reduced energy cost as well as pollution. The system is equipped with four input sensors; two soil moisture sensors, two level detection sensors. Soil moisture sensor measures the humidity of the soil, whereas the level detection sensors detect the level of water in the tank. The output sides consist of two solenoid valves, which are controlled respectively by two moistures sensors.
Renewable energy and sustainable communities: Alaska's wind generator experience.
Konkel, R Steven
2013-01-01
In 1984, the Alaska Department of Commerce and Economic Development (DCED) issued the State's first inventory/economic assessment of wind generators, documenting installed wind generator capacity and the economics of replacing diesel-fuel-generated electricity. Alaska's wind generation capacity had grown from hundreds of installed kilowatts to over 15.3 megawatts (MW) by January 2012. This article reviews data and conclusions presented in "Alaska's Wind Energy Systems; Inventory and Economic Assessment" (1). (Alaska Department of Commerce and Economic Development, S. Konkel, 1984). It provides a foundation and baseline for understanding the development of this renewable energy source. Today's technologies have evolved at an astonishing pace; a typical generator in an Alaska wind farm now is likely rated at 1.5-MW capacity, compared to the single-kilowatt (kW) machines present in 1984. Installed capacity has mushroomed, illustrated by Unalakleet's 600-kW wind farm dwarfing the original three 10-kW machines included in the 1984 inventory. Kodiak Electric had three 1.5-MW turbines installed at Pillar Mountain in 2009, with three additional turbines of 4.5-MW capacity installed in 2012. Utilities now actively plan for wind generation and compete for state funding. State of Alaska energy policy provides the context for energy project decision-making. Substantial renewable energy fund (REF) awards--$202,000,000 to date for 227 REF projects in the first 5 cycles of funding--along with numerous energy conservation programs--are now in place. Increasing investment in wind is driven by multiple factors. Stakeholders have interests both in public policy and meeting private investment objectives. Wind generator investors should consider project economics and potential impacts of energy decisions on human health. Specifically this article considers: changing environmental conditions in remote Alaska villages, impacts associated with climate change on human health, progress in better understanding wind energy potential through resource assessments and new tools for detailed feasibility and project planning, need for comprehensive monitoring and data analysis, and state funding requirements and opportunity costs. The energy policy choices ahead for Alaska will have important implications for Arctic population health, especially for those villages whose relatively small size and remote locations make energy a key component of subsistence lifestyles and community sustainability. Wind generation can contribute to meeting renewable energy goals and is a particularly important resource for rural and remote Alaskan communities currently dependent on diesel fuel for generating electricity and heat.
EVA 5 - Grunsfeld installs radiator
2002-03-08
STS109-315-007 (8 March 2002) --- Astronaut John M. Grunsfeld, STS-109 payload commander, anchored on the end of the Space Shuttle Columbias Remote Manipulator System (RMS) robotic arm, moves toward the giant Hubble Space Telescope (HST) temporarily hosted in the orbiters cargo bay. Astronaut Richard M. Linnehan (out of frame) works in tandem with Grunsfeld during this fifth and final session of extravehicular activity (EVA). Activities for the space walk centered around the Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) to install a Cryogenic Cooler and its Cooling System Radiator.
Business Case for Fuel Cells 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtin, Sandra; Gangi, Jennifer; Benjamin, Thomas G.
The report provides an overview of recent private sector fuel cell installations at U.S. businesses as of December 31, 2016. This list is by no means exhaustive. Over the past few decades, hundreds of thousands of fuel cells have been installed around the world, for primary or backup power, as well as in various other applications including portable and emergency backup power. Fuel cells have also been deployed in other applications such as heat and electricity for homes and apartments, material handling, passenger vehicles, buses, and remote, off-grid sites.
2007-02-16
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers from the Japan Aerospace Exploration Agency watch from a control area as the Remote Manipulator System, or robotic arm, is attached to a hoisting device to prepare it for installation to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
EVA 3 - Linnehan and Grunsfeld install new PCU
2002-03-06
STS109-E-5660 (6 March 2002) --- Astronauts John M. Grunsfeld (top) and Richard M. Linnehan participate in a 6 hour, 48 minute space walk designed to install a new Power Control Unit (PCU) on the Hubble Space Telescope (HST). The two went on to replace the original unit launched with the telescope in April 1990. Grunsfeld is on the end of Columbia's Remote Manipulator System (RMS) robotic arm, controlled from inside the crew cabin by astronaut Nancy J. Currie. The image was recorded with a digital still camera.
NASA Technical Reports Server (NTRS)
2000-01-01
Footage shows the Proton Rocket (containing the Zvezda module) ready for launch at the Baikonur Cosmodrome in Kazakhstan, Russia. The interior and exterior of Zvezda are seen during construction. Computerized simulations show the solar arrays deploying on Zvezda in space, the maneuvers of the module as it approaches and connects with the International Space Station (ISS), the installation of the Z1 truss on the ISS and its solar arrays deploying, and the installations of the Destiny Laboratory, Remote Manipulator System, and Kibo Experiment Module. Live footage then shows the successful launch of the Proton Rocket.
NASA Astrophysics Data System (ADS)
Azarbayejani, M.; Jalalpour, M.; El-Osery, A. I.; Reda Taha, M. M.
2011-08-01
In this paper, an innovative field application of a structural health monitoring (SHM) system using field programmable gate array (FPGA) technology and wireless communication is presented. The new SHM system was installed to monitor a reinforced concrete (RC) bridge on Interstate 40 (I-40) in Tucumcari, New Mexico. This newly installed system allows continuous remote monitoring of this bridge using solar power. Details of the SHM component design and installation are discussed. The integration of FPGA and solar power technologies make it possible to remotely monitor infrastructure with limited access to power. Furthermore, the use of FPGA technology enables smart monitoring where data communication takes place on-need (when damage warning signs are met) and on-demand for periodic monitoring of the bridge. Such a system enables a significant cut in communication cost and power demands which are two challenges during SHM operation. Finally, a three-dimensional finite element (FE) model of the bridge was developed and calibrated using a static loading field test. This model is then used for simulating damage occurrence on the bridge. Using the proposed automation process for SHM will reduce human intervention significantly and can save millions of dollars currently spent on prescheduled inspection of critical infrastructure worldwide.
The inherent weaknesses in industrial control systems devices; hacking and defending SCADA systems
NASA Astrophysics Data System (ADS)
Bianco, Louis J.
The North American Electric Reliability Corporation (NERC) is about to enforce their NERC Critical Infrastructure Protection (CIP) Version Five and Six requirements on July 1st 2016. The NERC CIP requirements are a set of cyber security standards designed to protect cyber assets essential the reliable operation of the electric grid. The new Version Five and Six requirements are a major revision to the Version Three (currently enforced) requirements. The new requirements also bring substations into scope alongside Energy Control Centers. When the Version Five requirements were originally drafted they were vague, causing in depth discussions throughout the industry. The ramifications of these requirements has made owners look at their systems in depth, questioning how much money it will take to meet these requirements. Some owners saw backing down from routable networks to non-routable as a means to save money as they would be held to less requirements within the standards. Some owners saw removing routable connections as a proper security move. The purpose of this research was to uncover the inherent weaknesses in Industrial Control Systems (ICS) devices; to show how ICS devices can be hacked and figure out potential protections for these Critical Infrastructure devices. In addition, this research also aimed to validate the decision to move from External Routable connectivity to Non-Routable connectivity, as a security measure and not as a means of savings. The results reveal in order to ultimately protect Industrial Control Systems they must be removed from the Internet and all bi-directional external routable connections must be removed. Furthermore; non-routable serial connections should be utilized, and these non-routable serial connections should be encrypted on different layers of the OSI model. The research concluded that most weaknesses in SCADA systems are due to the inherent weaknesses in ICS devices and because of these weaknesses, human intervention is the biggest threat to SCADA systems.
Modeling DNP3 Traffic Characteristics of Field Devices in SCADA Systems of the Smart Grid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Huan; Cheng, Liang; Chuah, Mooi Choo
In the generation, transmission, and distribution sectors of the smart grid, intelligence of field devices is realized by programmable logic controllers (PLCs). Many smart-grid subsystems are essentially cyber-physical energy systems (CPES): For instance, the power system process (i.e., the physical part) within a substation is monitored and controlled by a SCADA network with hosts running miscellaneous applications (i.e., the cyber part). To study the interactions between the cyber and physical components of a CPES, several co-simulation platforms have been proposed. However, the network simulators/emulators of these platforms do not include a detailed traffic model that takes into account the impactsmore » of the execution model of PLCs on traffic characteristics. As a result, network traces generated by co-simulation only reveal the impacts of the physical process on the contents of the traffic generated by SCADA hosts, whereas the distinction between PLCs and computing nodes (e.g., a hardened computer running a process visualization application) has been overlooked. To generate realistic network traces using co-simulation for the design and evaluation of applications relying on accurate traffic profiles, it is necessary to establish a traffic model for PLCs. In this work, we propose a parameterized model for PLCs that can be incorporated into existing co-simulation platforms. We focus on the DNP3 subsystem of slave PLCs, which automates the processing of packets from the DNP3 master. To validate our approach, we extract model parameters from both the configuration and network traces of real PLCs. Simulated network traces are generated and compared against those from PLCs. Our evaluation shows that our proposed model captures the essential traffic characteristics of DNP3 slave PLCs, which can be used to extend existing co-simulation platforms and gain further insights into the behaviors of CPES.« less
NASA Astrophysics Data System (ADS)
Iungo, G.; Said, E. A.; Santhanagopalan, V.; Zhan, L.
2016-12-01
Power production of a wind farm and durability of wind turbines are strongly dependent on non-linear wake interactions occurring within a turbine array. Wake dynamics are highly affected by the specific site conditions, such as topography and local atmospheric conditions. Furthermore, contingencies through the life of a wind farm, such as turbine ageing and off-design operations, make prediction of wake interactions and power performance a great challenge in wind energy. In this work, operations of an onshore wind turbine array were monitored through lidar measurements, SCADA and met-tower data. The atmospheric wind field investing the wind farm was estimated by using synergistically the available data through five different methods, which are characterized by different confidence levels. By combining SCADA data and the lidar measurements, it was possible to estimate power losses connected with wake interactions. For this specific array, power losses were estimated to be 4% and 2% of the total power production for stable and convective atmospheric regimes, respectively. The entire dataset was then leveraged for the calibration of a data-driven RANS (DDRANS) solver for prediction of wind turbine wakes and power production. The DDRANS is based on a parabolic formulation of the Navier-Stokes equations with axisymmetry and boundary layer approximations, which allow achieving very low computational costs. Accuracy in prediction of wind turbine wakes and power production is achieved through an optimal tuning of the turbulence closure model. The latter is based on a mixing length model, which was developed based on previous wind turbine wake studies carried out through large eddy simulations and wind tunnel experiments. Several operative conditions of the wind farm under examination were reproduced through DDRANS for different stability regimes, wind directions and wind velocity. The results show that DDRANS is capable of achieving a good level of accuracy in prediction of power production and wake velocity field associated with the turbine array.
Geostellar: Remote Solar Energy Assessments Personalized
DOE Office of Scientific and Technical Information (OSTI.GOV)
2015-10-01
Geostellar has produced an online tool that generates a unique solar profile for homeowners to learn about the financial benefits to installing rooftop solar panels on their home. The website incorporates the physical building characteristics of the home, including shading, slope, and orientation of the roof, and applies electricity costs and incentives to determine the best solar energy estimated energy production values against actual installed rooftop photovoltaic systems. The validation conducted by NREL concluded that over three-quarters of Geostellar's potential size estimates are at least as large as the actual installed systems, indicating a correct assessment of roof availability. Inmore » addition, 87% of Geostellar's 25-year production estimates are within 90% of the actual PV Watts results.« less
New receiving line for the remote-steering antenna of the 140 GHz CTS diagnostics in the FTU Tokamak
NASA Astrophysics Data System (ADS)
D'Arcangelo, O.; Bin, W.; Bruschi, A.; Cappelli, M.; Fanale, F.; Gittini, G.; Pallotta, F.; Rocchi, G.; Tudisco, O.; Garavaglia, S.; Granucci, G.; Moro, A.; Tuccillo, A. A.
2018-01-01
A new receiving antenna for collecting signals of the Collective Thomson Scattering (CTS) diagnostics in FTU Tokamak has been recently installed. The squared corrugated section and the precisely defined length make it possible to receive from different directions by remotely steering the receiving mirrors. This type of Remote-Steering (RS) antennas, being studied on FTU for the DEMO Electron Cyclotron Heating (ECH) system launch, is already installed on the W7- X stellarator and will be tested in the next campaign. The transmission of the signal from the antenna in the tokamak hall to the CTS diagnostics hall will be mainly realized by means of oversized circular corrugated waveguides carrying the hybrid HE11 (quasi-gaussian) waveguide mode, with inclusion of a special smooth-waveguide section and a short run of reduced-size square-corrugated waveguide through the tokamak bio-shield. The coupling between different waveguide types is made with ellipsoidal focusing mirrors, using quasi-optical matching formulas between the gaussian-shaped beams in input and output to the waveguides. In this work, after a complete study of feasibility of the overall line, a design for the receiving line will be proposed, in order to realize an executive layout to be used as a guideline for the commissioning phase.
Cloud CPFP: a shotgun proteomics data analysis pipeline using cloud and high performance computing.
Trudgian, David C; Mirzaei, Hamid
2012-12-07
We have extended the functionality of the Central Proteomics Facilities Pipeline (CPFP) to allow use of remote cloud and high performance computing (HPC) resources for shotgun proteomics data processing. CPFP has been modified to include modular local and remote scheduling for data processing jobs. The pipeline can now be run on a single PC or server, a local cluster, a remote HPC cluster, and/or the Amazon Web Services (AWS) cloud. We provide public images that allow easy deployment of CPFP in its entirety in the AWS cloud. This significantly reduces the effort necessary to use the software, and allows proteomics laboratories to pay for compute time ad hoc, rather than obtaining and maintaining expensive local server clusters. Alternatively the Amazon cloud can be used to increase the throughput of a local installation of CPFP as necessary. We demonstrate that cloud CPFP allows users to process data at higher speed than local installations but with similar cost and lower staff requirements. In addition to the computational improvements, the web interface to CPFP is simplified, and other functionalities are enhanced. The software is under active development at two leading institutions and continues to be released under an open-source license at http://cpfp.sourceforge.net.
Laser remote sensing of an algal bloom in a freshwater reservoir
NASA Astrophysics Data System (ADS)
Grishin, M. Ya; Lednev, V. N.; Pershin, S. M.; Bunkin, A. F.; Kobylyanskiy, V. V.; Ermakov, S. A.; Kapustin, I. A.; Molkov, A. A.
2016-12-01
Laser remote sensing of an algal bloom in a freshwater reservoir on the Volga River in central Russia was carried out. The compact Raman lidar was installed on a small ship to probe the properties of the surface water layer in different typical regions of Gorky Water Reservoir. Elastic and Raman scattering as well as chlorophyll fluorescence were quantified, mapped and compared with data acquired by a commercial salinity, temperature and depth probe (STD probe) equipped with a blue-green algae sensor. Good correlation between lidar and STD measurements was established.
The EPICS-based remote control system for muon beam line devices at J-PARC MUSE
NASA Astrophysics Data System (ADS)
Ito, T. U.; Nakahara, K.; Kawase, M.; Fujimori, H.; Kobayashi, Y.; Higemoto, W.; Miyake, Y.
2010-04-01
The remote control system for muon beam line devices of J-PARC MUSE has been developed with the Experimental Physics and Industrial Control System (EPICS). The EPICS input/output controller was installed in standard Linux PCs for slow control of the devices. Power supplies for 21 magnetic elements and four slit controllers for the decay-surface muon beam line in the Materials and Life Science Experimental Facility are now accessible via Ethernet from a graphical user interface which has been composed using the Motif Editor and Display Manger.
Innovative remotely-controlled bending device for thin silicon and germanium crystals
NASA Astrophysics Data System (ADS)
De Salvador, D.; Carturan, S.; Mazzolari, A.; Bagli, E.; Bandiera, L.; Durighello, C.; Germogli, G.; Guidi, V.; Klag, P.; Lauth, W.; Maggioni, G.; Romagnoni, M.; Sytov, A.
2018-04-01
Steering of negatively charged particle beams below 1 GeV has demonstrated to be possible with thin bent silicon and germanium crystals. A newly designed mechanical holder was used for bending crystals, since it allows a remotely-controlled adjustment of crystal bending and compensation of unwanted torsion. Bent crystals were installed and tested at the MAMI Mainz MIcrotron to achieve steering of 0.855-GeV electrons at different bending radii. We report the description and characterization of the innovative bending device developed at INFN Laboratori Nazionali di Legnaro (LNL).
Incorporation of a PbSe Array Based Spectrograph into EPICS using LabView at the JLab FEL Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. Hardy; S.V. Benson; Michelle D. Shinn
2005-08-21
A real-time spectrograph with a 1Hz update rate was designed and installed at the JLab FEL facility using a Cal Sensors PbSe array and a Roper Scientific SpectraPro 300 monochrometer. This paper describes the implementation of EPICS channel access on a remote PC running LabView with modification of vendor supplied LabView VI's to allow display of FEL light spectra in real-time on a remote workstation. This allows PC based diagnostics to be used in EPICS.
Test-bed for the remote health monitoring system for bridge structures using FBG sensors
NASA Astrophysics Data System (ADS)
Lee, Chin-Hyung; Park, Ki-Tae; Joo, Bong-Chul; Hwang, Yoon-Koog
2009-05-01
This paper reports on test-bed for the long-term health monitoring system for bridge structures employing fiber Bragg grating (FBG) sensors, which is remotely accessible via the web, to provide real-time quantitative information on a bridge's response to live loading and environmental changes, and fast prediction of the structure's integrity. The sensors are attached on several locations of the structure and connected to a data acquisition system permanently installed onsite. The system can be accessed through remote communication using an optical cable network, through which the evaluation of the bridge behavior under live loading can be allowed at place far away from the field. Live structural data are transmitted continuously to the server computer at the central office. The server computer is connected securely to the internet, where data can be retrieved, processed and stored for the remote web-based health monitoring. Test-bed revealed that the remote health monitoring technology will enable practical, cost-effective, and reliable condition assessment and maintenance of bridge structures.
Earth Resources Stewardship at Department of Defense Installations
1994-03-01
Roberts, Kevin Morrison, and Carlos Latorre, USM. Mr. J. D. Lashlee (GL) contributed to the sections on remote sensing imageky, mobility, and geographic...nearby observation wells. The test measurements are: static water level before pumping is started, pump rate, and dynamic waer levels measured at
Computer Networking with the Victorian Correspondence School.
ERIC Educational Resources Information Center
Conboy, Ian
During 1985 the Education Department installed two-way radios in 44 remote secondary schools in Victoria, Australia, to improve turn-around time for correspondence assignments. Subsequently, teacher supervisors at Melbourne's Correspondence School sought ways to further augument audio interactivity with computer networking. Computer equipment was…
An intelligent remote monitoring system for artificial heart.
Choi, Jaesoon; Park, Jun W; Chung, Jinhan; Min, Byoung G
2005-12-01
A web-based database system for intelligent remote monitoring of an artificial heart has been developed. It is important for patients with an artificial heart implant to be discharged from the hospital after an appropriate stabilization period for better recovery and quality of life. Reliable continuous remote monitoring systems for these patients with life support devices are gaining practical meaning. The authors have developed a remote monitoring system for this purpose that consists of a portable/desktop monitoring terminal, a database for continuous recording of patient and device status, a web-based data access system with which clinicians can access real-time patient and device status data and past history data, and an intelligent diagnosis algorithm module that noninvasively estimates blood pump output and makes automatic classification of the device status. The system has been tested with data generation emulators installed on remote sites for simulation study, and in two cases of animal experiments conducted at remote facilities. The system showed acceptable functionality and reliability. The intelligence algorithm also showed acceptable practicality in an application to animal experiment data.
Remote video assessment for missile launch facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, G.G.; Stewart, W.A.
1995-07-01
The widely dispersed, unmanned launch facilities (LFs) for land-based ICBMs (intercontinental ballistic missiles) currently do not have visual assessment capability for existing intrusion alarms. The security response force currently must assess each alarm on-site. Remote assessment will enhance manpower, safety, and security efforts. Sandia National Laboratories was tasked by the USAF Electronic Systems Center to research, recommend, and demonstrate a cost-effective remote video assessment capability at missile LFs. The project`s charter was to provide: system concepts; market survey analysis; technology search recommendations; and operational hardware demonstrations for remote video assessment from a missile LF to a remote security center viamore » a cost-effective transmission medium and without using visible, on-site lighting. The technical challenges of this project were to: analyze various video transmission media and emphasize using the existing missile system copper line which can be as long as 30 miles; accentuate and extremely low-cost system because of the many sites requiring system installation; integrate the video assessment system with the current LF alarm system; and provide video assessment at the remote sites with non-visible lighting.« less
An airborne remote sensing platform of the Helsinki University of Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nikulainen, M.; Hallikainen, M.; Kemppinen, M.
1996-10-01
In 1994 Helsinki University of Technology acquired a Short SC7 Skyvan turboprop aircraft to be modified to carry remote sensing instruments. As the aircraft is originally designed to carry heavy and space consuming cargo, a modification program was implemented to make the aircraft feasible for remote sensing operations. The twelve-month long modification program had three design objectives: flexibility, accessibility and cost efficiency. The aircraft interior and electrical system were modified. Furthermore, the aircraft is equipped with DGPS-navigation system, multi-channel radiometer system and side looking airborne radar. Future projects include installation of local area network, attitude GPS system, imaging spectrometer andmore » 1.4 GHz radiometer. 6 refs., 5 figs., 1 tab.« less
Evaluation of high-voltage, high-power, solid-state remote power controllers for amps
NASA Technical Reports Server (NTRS)
Callis, Charles P.
1987-01-01
The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.
Satellite remote sensing for hydrology and water management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barrett, E.C.; Power, C.H.; Micallef, A.
Interest in satellite remote sensing is fast moving away from pure science and individual case studies towards truly operational applications. At the same time the micro-computer revolution is ensuring that data reception and processing facilities need no longer be the preserve of a small number of global centers, but can be common-place installations in smaller countries and even local regional agency offices or laboratories. As remote sensing matures, and its applications proliferate, a new type of treatment is required to ensure both that decision makers, managers and engineers with problems to solve are informed of today's opportunities and that scientistsmore » are provided with integrated overviews of the ever-growing need for their services. This book addresses these needs uniquely focusing on the area bounded by satellite remote sensing, pure and applied hydrological sciences, and a specific world region, namely the Mediterranean basin.« less
Collegiate Cyber Defense Competition Effort
2018-03-01
Energy – an electrical utility company. • 2016 : ODIN Security – a small aerospace and defense contracting firm Approved for Public Release...to secure supervisory control and data acquisition (SCADA) networks. Approved for Public Release; Distribution Unlimited 7 During the 2016 NCCDC...COLLEGIATE CYBER DEFENSE COMPETITION EFFORT UNIVERSITY OF TEXAS AT SAN ANTONIO MARCH 2018 FINAL TECHNICAL REPORT APPROVED FOR PUBLIC RELEASE
2014-09-01
executable that is setuid root.4 fingerd The Morris worm exploited a buffer overflow in the fingerd program to gain unauthorized access to computer...in other taxonomies. There are still holes ; in fact, none of the vulnerabilities that Bishop discussed have a clear place in this taxonomy until a
First Carlsberg Meridian Telescope (CMT) CCD Catalogue.
NASA Astrophysics Data System (ADS)
Bélizon, F.; Muiños, J. L.; Vallejo, M.; Evans, D. W.; Irwin, M.; Helmer, L.
2003-11-01
The Carlsberg Meridian Telescope (CMT) is a telescope owned by Copenhagen University Observatory (CUO). It was installed in the Spanish observatory of El Roque de los Muchachos on the island of La Palma (Canary Islands) in 1984. It is operated jointly by the CUO, the Institute of Astronomy, Cambridge (IoA) and the Real Instituto y Observatorio de la Armada of Spain (ROA) in the framework of an international agreement. From 1984 to 1998 the instrument was provided with a moving slit micrometer and with its observations a series of 11 catalogues were published, `Carlsberg Meridian Catalogue La Palma (CMC No 1-11)'. Since 1997, the telescope has been controlled remotely via Internet. The three institutions share this remote control in periods of approximately three months. In 1998, the CMT was upgraded by installing as sensor, a commercial Spectrasource CCD camera as a test of the possibility of performing meridian transits observed in drift-scan mode. Once this was shown possible, in 1999, a second model of CCD camera, built in the CUO workshop with a better performance, was installed. The Spectrasource camera was loaned to ROA by CUO and is now installed in the San Fernando Automatic Meridian Circle in San Juan (CMASF). In 1999, the observations were started of a sky survey from -3deg to +30deg in declination. In July 2002, a first release of the survey was published, with the positions of the observed stars in the band between -3deg and +3deg in declination. This oral communication will present this first release of the survey.
Wei, Yawei; Venayagamoorthy, Ganesh Kumar
2017-09-01
To prevent large interconnected power system from a cascading failure, brownout or even blackout, grid operators require access to faster than real-time information to make appropriate just-in-time control decisions. However, the communication and computational system limitations of currently used supervisory control and data acquisition (SCADA) system can only deliver delayed information. However, the deployment of synchrophasor measurement devices makes it possible to capture and visualize, in near-real-time, grid operational data with extra granularity. In this paper, a cellular computational network (CCN) approach for frequency situational intelligence (FSI) in a power system is presented. The distributed and scalable computing unit of the CCN framework makes it particularly flexible for customization for a particular set of prediction requirements. Two soft-computing algorithms have been implemented in the CCN framework: a cellular generalized neuron network (CCGNN) and a cellular multi-layer perceptron network (CCMLPN), for purposes of providing multi-timescale frequency predictions, ranging from 16.67 ms to 2 s. These two developed CCGNN and CCMLPN systems were then implemented on two different scales of power systems, one of which installed a large photovoltaic plant. A real-time power system simulator at weather station within the Real-Time Power and Intelligent Systems (RTPIS) laboratory at Clemson, SC, was then used to derive typical FSI results. Copyright © 2017 Elsevier Ltd. All rights reserved.
MultiNet TCP/P/IP for VAX/VMS update
NASA Technical Reports Server (NTRS)
Vance, L. Stuart
1991-01-01
Outlines of device support; DECnet interoperability; installation; MultiNet services; domain name server; Telnet; FTP; SMTP; DECwindows over TCP/IP; BSD r services; remote printing; RPC services and NFS server; NFS client; netcontrol; diagnostics; programming support; and MultiNet features are presented in viewgraph format.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Information on glove-bag installation, equipment and supplies, and work practices is contained in the... (or owner or operator under common control). Leak-tight means that solids or liquids cannot escape or... such as cliffs, lakes or other large bodies of water, deep and wide ravines, and mountains. Remoteness...
The RIACS Intelligent Auditing and Categorizing System
NASA Technical Reports Server (NTRS)
Bishop, Matt
1988-01-01
The organization of the RIACS auditing package is described along with how to installation instructions and how to interpret the output. How to set up both local and remote file system auditing is given. Logging is done on a time driven basis, and auditing in a passive mode.
44 CFR 206.117 - Housing assistance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... permanent housing in insular areas outside the continental United States and in other remote locations when... provide assistance for the reasonable cost of any transportation, utility hookups, or installation of a... on the household's bedroom requirement and the location of the rental unit. (C) All utility costs and...
44 CFR 206.117 - Housing assistance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... permanent housing in insular areas outside the continental United States and in other remote locations when... provide assistance for the reasonable cost of any transportation, utility hookups, or installation of a... on the household's bedroom requirement and the location of the rental unit. (C) All utility costs and...
44 CFR 206.117 - Housing assistance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... permanent housing in insular areas outside the continental United States and in other remote locations when... provide assistance for the reasonable cost of any transportation, utility hookups, or installation of a... on the household's bedroom requirement and the location of the rental unit. (C) All utility costs and...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-18
... Remote Sensing Network, a system of interconnected hydrophones installed in the marine environment of... stock(s) for subsistence uses (where relevant), and if the permissible methods of taking and... IHA, WSDOT's wingwalls replacement project at the Bremerton Ferry Terminal will only use vibratory...
7 CFR 1755.397 - RUS performance specification for line concentrators.
Code of Federal Regulations, 2010 CFR
2010-01-01
... importance in the design, manufacture and installation of the equipment. The equipment shall automatically... concentrator terminal units shall be designed such that there will be no more than 4 hours of total outages in... total signaling period. (ii) Subscriber dial interdigital time. The remote and central office LC...
DOT National Transportation Integrated Search
2008-06-01
The objective of this research study was to perform a thorough evaluation of the feasibility and cost implications for initial system installation and ongoing program and maintenance costs for a land port of entry truck emissions program utilizing he...
Video monitoring system for car seat
NASA Technical Reports Server (NTRS)
Elrod, Susan Vinz (Inventor); Dabney, Richard W. (Inventor)
2004-01-01
A video monitoring system for use with a child car seat has video camera(s) mounted in the car seat. The video images are wirelessly transmitted to a remote receiver/display encased in a portable housing that can be removably mounted in the vehicle in which the car seat is installed.
Remote control flare stack igniter for combustible gases
NASA Technical Reports Server (NTRS)
Ray, W. L.
1972-01-01
Device has been designed and developed for igniting nonrecoverable combustible gases and sustaining combustion of gases evolving from various gas vent stacks. Igniter is superior to existing systems because of simplicity of operation, low cost fabrication, installation, operational and maintainability features, and excellent reliability in all phases of required operations.
32 CFR Appendix A to Part 310 - Safeguarding Personally Identifiable Information (PII)
Code of Federal Regulations, 2012 CFR
2012-07-01
... all computer products containing classified data in accordance with the requirements of DoD 5200.1-R... computer environments outside the data processing installation (such as, remote job entry stations... process classified material have adequate procedures and security for the purposes of this Regulation...
32 CFR Appendix A to Part 310 - Safeguarding Personally Identifiable Information (PII)
Code of Federal Regulations, 2010 CFR
2010-07-01
... all computer products containing classified data in accordance with the requirements of DoD 5200.1-R... computer environments outside the data processing installation (such as, remote job entry stations... process classified material have adequate procedures and security for the purposes of this Regulation...
32 CFR Appendix A to Part 310 - Safeguarding Personally Identifiable Information (PII)
Code of Federal Regulations, 2011 CFR
2011-07-01
... all computer products containing classified data in accordance with the requirements of DoD 5200.1-R... computer environments outside the data processing installation (such as, remote job entry stations... process classified material have adequate procedures and security for the purposes of this Regulation...
32 CFR Appendix A to Part 310 - Safeguarding Personally Identifiable Information (PII)
Code of Federal Regulations, 2014 CFR
2014-07-01
... all computer products containing classified data in accordance with the requirements of DoD 5200.1-R... computer environments outside the data processing installation (such as, remote job entry stations... process classified material have adequate procedures and security for the purposes of this Regulation...
32 CFR Appendix A to Part 310 - Safeguarding Personally Identifiable Information (PII)
Code of Federal Regulations, 2013 CFR
2013-07-01
... all computer products containing classified data in accordance with the requirements of DoD 5200.1-R... computer environments outside the data processing installation (such as, remote job entry stations... process classified material have adequate procedures and security for the purposes of this Regulation...
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2014 CFR
2014-07-01
... emergency lighting and power systems in vessel control and propulsion machinery spaces. (5) Main propulsion...) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle... power failure alarm. (vi) Each remote steering gear power unit failure alarm. (vii) The full movement of...
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2012 CFR
2012-07-01
... emergency lighting and power systems in vessel control and propulsion machinery spaces. (5) Main propulsion...) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle... power failure alarm. (vi) Each remote steering gear power unit failure alarm. (vii) The full movement of...
2013-12-01
21 a. Siberian Pipeline Explosion (1982) ............................21 b. Chevron Emergency Alert...the fifth domain: Are the mouse and keyboard the new weapons of conflict?,” The Economist, July 1, 2010, http://www.economist.com/node/16478792. 15...a. Siberian Pipeline Explosion (1982) In 1982, intruders planted a Trojan horse in the SCADA system that controls the Siberian Pipeline. This is the
View_SPECPR: Software for Plotting Spectra (Installation Manual and User's Guide, Version 1.2)
Kokaly, Raymond F.
2008-01-01
This document describes procedures for installing and using the 'View_SPECPR' software system to plot spectra stored in SPECPR (SPECtrum Processing Routines) files. The View_SPECPR software is comprised of programs written in IDL (Interactive Data Language) that run within the ENVI (ENvironment for Visualizing Images) image processing system. SPECPR files are used by earth-remote-sensing scientists and planetary scientists for storing spectra collected by laboratory, field, and remote sensing instruments. A widely distributed SPECPR file is the U.S. Geological Survey (USGS) spectral library that contains thousands of spectra of minerals, vegetation, and man-made materials (Clark and others, 2007). SPECPR files contain reflectance data and associated wavelength and spectral resolution data, as well as meta-data on the time and date of collection and spectrometer settings. Furthermore, the SPECPR file automatically tracks changes to data records through its 'history' fields. For more details on the format and content of SPECPR files, see Clark (1993). For more details on ENVI, see ITT (2008). This program has been updated using an ENVI 4.5/IDL7.0 full license operating on a Windows XP operating system and requires the installation of the iTools components of IDL7.0; however, this program should work with full licenses on UNIX/LINUX systems. This software has not been tested with ENVI licenses on Windows Vista or Apple Operating Systems.
An ethernet/IP security review with intrusion detection applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laughter, S. A.; Williams, R. D.
2006-07-01
Supervisory Control and Data Acquisition (SCADA) and automation networks, used throughout utility and manufacturing applications, have their own specific set of operational and security requirements when compared to corporate networks. The modern climate of heightened national security and awareness of terrorist threats has made the security of these systems of prime concern. There is a need to understand the vulnerabilities of these systems and how to monitor and protect them. Ethernet/IP is a member of a family of protocols based on the Control and Information Protocol (CIP). Ethernet/IP allows automation systems to be utilized on and integrated with traditional TCP/IPmore » networks, facilitating integration of these networks with corporate systems and even the Internet. A review of the CIP protocol and the additions Ethernet/IP makes to it has been done to reveal the kind of attacks made possible through the protocol. A set of rules for the SNORT Intrusion Detection software is developed based on the results of the security review. These can be used to monitor, and possibly actively protect, a SCADA or automation network that utilizes Ethernet/IP in its infrastructure. (authors)« less
A Measurement and Power Line Communication System Design for Renewable Smart Grids
NASA Astrophysics Data System (ADS)
Kabalci, E.; Kabalci, Y.
2013-10-01
The data communication over the electric power lines can be managed easily and economically since the grid connections are already spread around all over the world. This paper investigates the applicability of Power Line Communication (PLC) in an energy generation system that is based on photovoltaic (PV) panels with the modeling study in Matlab/Simulink. The Simulink model covers the designed PV panels, boost converter with Perturb and Observe (P&O) control algorithm, full bridge inverter, and the binary phase shift keying (BPSK) modem that is utilized to transfer the measured data over the power lines. This study proposes a novel method to use the electrical power lines not only for carrying the line voltage but also to transmit the measurements of the renewable energy generation plants. Hence, it is aimed at minimizing the additional monitoring costs such as SCADA, Ethernet-based or GSM based systems by using the proposed technique. Although this study is performed with solar power plants, the proposed model can be applied to other renewable generation systems. Consequently, the usage of the proposed technique instead of SCADA or Ethernet-based systems eliminates additional monitoring costs.
NASA Astrophysics Data System (ADS)
Osborne, Martin; Marenco, Franco; Adam, Mariana; Buxmann, Joelle; Haywood, Jim
2018-04-01
The Met Office has recently established a series of 10 lidar / sun-photometer installations across the UK, consolidating their ash / aerosol remote sensing capabilities [1]. In addition to this network, the Met Office have acquired the Civil Contingency Aircraft (MOCCA) which allows airborne in-situ measurements of ash / aerosol scattering and size-distributions. Two case studies are presented in which mass concentrations of Saharan dust are obtained remotely using lidar returns, and are then compared with those obtained in-situ. A thorough analysis of the mass concentration uncertainty will be provided at the conference.
Teaching infant car seat installation via interactive visual presence: An experimental trial.
Schwebel, David C; Johnston, Anna; Rouse, Jenni
2017-02-17
A large portion of child restraint systems (car seats) are installed incorrectly, especially when first-time parents install infant car seats. Expert instruction greatly improves the accuracy of car seat installation but is labor intensive and difficult to obtain for many parents. This study was designed to evaluate the efficacy of 3 ways of communicating instructions for proper car seat installation: phone conversation; HelpLightning, a mobile application (app) that offers virtual interactive presence permitting both verbal and interactive (telestration) visual communication; and the manufacturer's user manual. A sample of 39 young adults of child-bearing age who had no previous experience installing car seats were recruited and randomly assigned to install an infant car seat using guidance from one of those 3 communication sources. Both the phone and interactive app were more effective means to facilitate accurate car seat installation compared to the user manual. There was a trend for the app to offer superior communication compared to the phone, but that difference was not significant in most assessments. The phone and app groups also installed the car seat more efficiently and perceived the communication to be more effective and their installation to be more accurate than those in the user manual group. Interactive communication may help parents install car seats more accurately than using the manufacturer's manual alone. This was an initial study with a modestly sized sample; if results are replicated in future research, there may be reason to consider centralized "call centers" that provide verbal and/or interactive visual instruction from remote locations to parents installing car seats, paralleling the model of centralized Poison Control centers in the United States.
Renewable energy and sustainable communities: Alaska's wind generator experience†
Konkel, R. Steven
2013-01-01
Background In 1984, the Alaska Department of Commerce and Economic Development (DCED) issued the State's first inventory/economic assessment of wind generators, documenting installed wind generator capacity and the economics of replacing diesel-fuel-generated electricity. Alaska's wind generation capacity had grown from hundreds of installed kilowatts to over 15.3 megawatts (MW) by January 2012. Method This article reviews data and conclusions presented in “Alaska's Wind Energy Systems; Inventory and Economic Assessment” (1). (Alaska Department of Commerce and Economic Development, S. Konkel, 1984). It provides a foundation and baseline for understanding the development of this renewable energy source. Results Today's technologies have evolved at an astonishing pace; a typical generator in an Alaska wind farm now is likely rated at 1.5-MW capacity, compared to the single-kilowatt (kW) machines present in 1984. Installed capacity has mushroomed, illustrated by Unalakleet's 600-kW wind farm dwarfing the original three 10-kW machines included in the 1984 inventory. Kodiak Electric had three 1.5-MW turbines installed at Pillar Mountain in 2009, with three additional turbines of 4.5-MW capacity installed in 2012. Utilities now actively plan for wind generation and compete for state funding. Discussion State of Alaska energy policy provides the context for energy project decision-making. Substantial renewable energy fund (REF) awards – $202,000,000 to date for 227 REF projects in the first 5 cycles of funding – along with numerous energy conservation programs – are now in place. Increasing investment in wind is driven by multiple factors. Stakeholders have interests both in public policy and meeting private investment objectives. Wind generator investors should consider project economics and potential impacts of energy decisions on human health. Specifically this article considers:changing environmental conditions in remote Alaska villages,impacts associated with climate change on human health,progress in better understanding wind energy potential through resource assessments and new tools for detailed feasibility and project planning,need for comprehensive monitoring and data analysis, andstate funding requirements and opportunity costs. Conclusion The energy policy choices ahead for Alaska will have important implications for Arctic population health, especially for those villages whose relatively small size and remote locations make energy a key component of subsistence lifestyles and community sustainability. Wind generation can contribute to meeting renewable energy goals and is a particularly important resource for rural and remote Alaskan communities currently dependent on diesel fuel for generating electricity and heat. PMID:23971014
NASA Astrophysics Data System (ADS)
Hiraki, M.; Yamada, Y.; Chavas, L. M. G.; Matsugaki, N.; Igarashi, N.; Wakatsuki, S.
2013-03-01
To achieve fully-automated and/or remote data collection in high-throughput X-ray experiments, the Structural Biology Research Centre at the Photon Factory (PF) has installed PF automated mounting system (PAM) for sample exchange robots at PF macromolecular crystallography beamlines BL-1A, BL-5A, BL-17A, AR-NW12A and AR-NE3A. We are upgrading the experimental systems, including the PAM for stable and efficient operation. To prevent human error in automated data collection, we installed a two-dimensional barcode reader for identification of the cassettes and sample pins. Because no liquid nitrogen pipeline in the PF experimental hutch is installed, the users commonly add liquid nitrogen using a small Dewar. To address this issue, an automated liquid nitrogen filling system that links a 100-liter tank to the robot Dewar has been installed on the PF macromolecular beamline. Here we describe this new implementation, as well as future prospects.
The International Space Station: A Unique Platform For Terrestrial Remote Sensing
NASA Technical Reports Server (NTRS)
Stefanov, William L.; Evans, Cynthia A.
2012-01-01
The International Space Station (ISS) became operational in November of 2000, and until recently remote sensing activities and operations have focused on handheld astronaut photography of the Earth. This effort builds from earlier NASA and Russian space programs (e.g. Evans et al. 2000; Glazovskiy and Dessinov 2000). To date, astronauts have taken more than 600,000 images of the Earth s land surface, oceans, and atmospheric phenomena from orbit using film and digital cameras as part two payloads: NASA s Crew Earth Observations experiment (http://eol.jsc.nasa.gov/) and Russia s Uragan experiment (Stefanov et al. 2012). Many of these images have unique attributes - varying look angles, ground resolutions, and illumination - that are not available from other remote sensing platforms. Despite this large volume of imagery and clear capability for Earth remote sensing, the ISS historically has not been perceived as an Earth observations platform by many remote sensing scientists. With the recent installation of new facilities and sophisticated sensor systems, and additional systems manifested and in development, that perception is changing to take advantage of the unique capabilities and viewing opportunities offered by the ISS.
Bradbury, Kyle; Saboo, Raghav; L. Johnson, Timothy; Malof, Jordan M.; Devarajan, Arjun; Zhang, Wuming; M. Collins, Leslie; G. Newell, Richard
2016-01-01
Earth-observing remote sensing data, including aerial photography and satellite imagery, offer a snapshot of the world from which we can learn about the state of natural resources and the built environment. The components of energy systems that are visible from above can be automatically assessed with these remote sensing data when processed with machine learning methods. Here, we focus on the information gap in distributed solar photovoltaic (PV) arrays, of which there is limited public data on solar PV deployments at small geographic scales. We created a dataset of solar PV arrays to initiate and develop the process of automatically identifying solar PV locations using remote sensing imagery. This dataset contains the geospatial coordinates and border vertices for over 19,000 solar panels across 601 high-resolution images from four cities in California. Dataset applications include training object detection and other machine learning algorithms that use remote sensing imagery, developing specific algorithms for predictive detection of distributed PV systems, estimating installed PV capacity, and analysis of the socioeconomic correlates of PV deployment. PMID:27922592
NASA Astrophysics Data System (ADS)
Bradbury, Kyle; Saboo, Raghav; L. Johnson, Timothy; Malof, Jordan M.; Devarajan, Arjun; Zhang, Wuming; M. Collins, Leslie; G. Newell, Richard
2016-12-01
Earth-observing remote sensing data, including aerial photography and satellite imagery, offer a snapshot of the world from which we can learn about the state of natural resources and the built environment. The components of energy systems that are visible from above can be automatically assessed with these remote sensing data when processed with machine learning methods. Here, we focus on the information gap in distributed solar photovoltaic (PV) arrays, of which there is limited public data on solar PV deployments at small geographic scales. We created a dataset of solar PV arrays to initiate and develop the process of automatically identifying solar PV locations using remote sensing imagery. This dataset contains the geospatial coordinates and border vertices for over 19,000 solar panels across 601 high-resolution images from four cities in California. Dataset applications include training object detection and other machine learning algorithms that use remote sensing imagery, developing specific algorithms for predictive detection of distributed PV systems, estimating installed PV capacity, and analysis of the socioeconomic correlates of PV deployment.
Bradbury, Kyle; Saboo, Raghav; L Johnson, Timothy; Malof, Jordan M; Devarajan, Arjun; Zhang, Wuming; M Collins, Leslie; G Newell, Richard
2016-12-06
Earth-observing remote sensing data, including aerial photography and satellite imagery, offer a snapshot of the world from which we can learn about the state of natural resources and the built environment. The components of energy systems that are visible from above can be automatically assessed with these remote sensing data when processed with machine learning methods. Here, we focus on the information gap in distributed solar photovoltaic (PV) arrays, of which there is limited public data on solar PV deployments at small geographic scales. We created a dataset of solar PV arrays to initiate and develop the process of automatically identifying solar PV locations using remote sensing imagery. This dataset contains the geospatial coordinates and border vertices for over 19,000 solar panels across 601 high-resolution images from four cities in California. Dataset applications include training object detection and other machine learning algorithms that use remote sensing imagery, developing specific algorithms for predictive detection of distributed PV systems, estimating installed PV capacity, and analysis of the socioeconomic correlates of PV deployment.
NASA Astrophysics Data System (ADS)
Chambers, J. E.; Meldrum, P.; Gunn, D.; Wilkinson, P. B.; Uhlemann, S.; Swift, R. T.; Kuras, O.; Inauen, C.; Hutchinson, D.; Butler, S.
2016-12-01
ERT monitoring has been demonstrated in numerous studies as an effective means of imaging near surface processes for applications as diverse as permafrost studies and contaminated land assessment. A limiting factor in applying time-lapse ERT for long-term studies in remote locations has been the availability of cost-effective ERT measurement systems designed specifically for monitoring applications. Typically, monitoring is undertaken using repeated manual data collection, or by building conventional survey instruments into a monitoring setup. The latter often requires high power and is therefore difficult to operate remotely without access to mains electricity. We describe the development of a low-power resistivity imaging system designed specifically for remote monitoring, taking advantage of, e.g., solar power and data telemetry. Here, we present the results of two field deployments. The system has been installed on an active railway cutting to provide insights into the effect of vegetation on the moisture dynamics in unstable infrastructure slopes and to gather subsurface information for pro-active remediation measures. The system, comprising 255 electrodes, acquires 4596 reciprocal measurement pairs twice daily during standard operation. In case of severe weather events, the measurement schedule is reactively changed, to gather high temporal resolution data to image rainfall infiltration processes. The system has also been installed along a leaking and marginally stable canal embankment; a less favourable location for remote monitoring, with limited solar power and poor mobile reception. Nevertheless, the acquired data indicated the effectiveness of remedial actions on the canal. The ERT results showed that one leak was caused by the canal and fixed during remediation, while two other "leaks" were shown to be effects of groundwater dynamics. The availability of cost-effective, low-power ERT monitoring instrumentation, combined with an automated workflow of data processing and visualisation, has the potential to contribute to a step-change in the management and early warning of slope instability.
USDA-ARS?s Scientific Manuscript database
The calibration and validation of soil moisture remote sensing products is complicated by the logistics of installing a soil moisture network for a long term period in an active landscape. Therefore, these stations are located along field boundaries or in non-representative sites with regards to so...
Scaling and calibration of a core validation site for the soil moisture active passive mission
USDA-ARS?s Scientific Manuscript database
The calibration and validation of soil moisture remote sensing products is complicated due to the logistics of installing a long term soil moisture monitoring network in an active landscape. It is more efficient to locate these stations along agricultural field boundaries, but unfortunately this oft...
Installation Restoration Program. Phase 1: Records Search, Whiteman AFB, Missouri
1984-03-26
Aquazene (Ciba-Geigy) was added to each remote site lagoon (A-i through N-i) on a one-time basis as an algicide . Brine line leakage has been noted at...layered strata are inclined down and away from the axes. AQUAZENE: an algicide . ARRS: Aerospace Rescue and Recovery Squadron. ARTESIAN: Ground water
USDA-ARS?s Scientific Manuscript database
In situ soil moisture monitoring networks are critical to the development of soil moisture remote sensing missions as well as agricultural and environmental management, weather forecasting and many other endeavors. These in situ networks are composed of a variety of sensors and installation practic...
Rivers of Energy: The Hydropower Potential. Worldwatch Paper No. 44.
ERIC Educational Resources Information Center
Deudney, Daniel
Described are the history, current status and future potential of hydroelectric power in the world. Issues discussed include the environmental and social impacts of dam construction, and the use of small-scale hydroelectric installations in developing nations. Also considered are hydroelectric development of the world's remote regions, the need to…
2015-10-01
Richard Biagioni , Program Manager Space and Missile Systems Center (SMC) Remote Sensing Space Environmental Branch (RSSE) 1050 E. Stewart Ave...Environmental Branch (SMC/RSSE) under MIPR# F3LGWD5009G003. The technical monitor was Richard Biagioni , SMC/RSSE. The work was performed by Kevin Bjella
Code of Federal Regulations, 2010 CFR
2010-07-01
... level sensing devices that activate an alarm or control the flow, or otherwise prevent discharges. (f) Equip pressure containers with high and low pressure sensing devices that activate an alarm or control... flow conditions, combination of pressure and flow, manual or remote control mechanisms. (k) Install a...
A Computer Lab that Students Use but Never See
ERIC Educational Resources Information Center
Young, Jeffrey R.
2008-01-01
North Carolina State University may never build another computer lab. Instead the university has installed racks of equipment in windowless rooms where students and professors never go. This article describes a project called the Virtual Computing Lab. Users enter it remotely from their own computers in dormitory rooms or libraries. They get all…
NASA Astrophysics Data System (ADS)
Mahmud, M. R.; Reba, M. N. M.; Jaw, S. W.; Arsyad, A.; Ibrahim, M. A. M.
2017-05-01
This paper developed a conceptual framework in determining the suitable location in installing the earth station for Ka-band satellite communication in Malaysia. This current evolution of high throughput satellites experienced major challenge due to Malaysian climate. Because Ka-band frequency is highly attenuated by the rainfall; it is an enormous challenge to define the most appropriate site for the static communication. Site diversity, a measure to anticipate this conflict by choosing less attenuated region and geographically change the transmission strategy on season basis require accurate spatio-temporal information on the geographical, environmental and hydro-climatology at local scale. Prior to that request, this study developed a conceptual framework to cater the needs. By using the digital spatial data, acquired from site measurement and remote sensing, the proposed framework applied a multiple criteria analysis to perform the tasks of site selection. With the advancement of high resolution remotely sensed data, site determination can be conducted as in Malaysia; accommodating a new, fast, and effective satellite communication. The output of this study is one of the pioneer contributions to create a high tech-society.
NASA Technical Reports Server (NTRS)
Hayakawa, K. K.; Udell, D. R.; Iwata, M. M.; Lytle, C. F.; Chrisco, R. M.; Greenough, C. S.; Walling, J. A.
1972-01-01
The results are presented of an investigation into the availability and performance capability of measurement components in the area of cryogenic temperature, pressure, flow and liquid detection components and high temperature strain gages. In addition, technical subjects allied to the components were researched and discussed. These selected areas of investigation were: (1) high pressure flange seals, (2) hydrogen embrittlement of pressure transducer diaphragms, (3) The effects of close-coupled versus remote transducer installation on pressure measurement, (4) temperature transducer configuration effects on measurements, and (5) techniques in temperature compensation of strain gage pressure transducers. The purpose of the program was to investigate the latest design and application techniques in measurement component technology and to document this information along with recommendations for upgrading measurement component designs for future S-2 derivative applications. Recommendations are provided for upgrading existing state-of-the-art in component design, where required, to satisfy performance requirements of S-2 derivative vehicles.
Conceptual design study: Cold water pipe systems for self-mounted OTEC powerplants
NASA Astrophysics Data System (ADS)
1981-02-01
The conceptual design and installation aspects of cold water pipes (CWP) systems for shelf mounted OTEC power plants in Puerto Rico and Hawaii are considered. The CWP systems using Fiberglass Reinforced Plastic (FRP) and steel were designed; the FRP, can be controlled by varying the core thickness; and steel is used as a structural material in offshore applications. A marine railway approach was chosen for installation of the CWP. Two methods for pulling the track for the railway down the pipe fairway to its final location are presented. The track is permanently fastened to the sloping seabed with piles installed by a remotely controlled cart that rides on the track itself. Both the marine railway and the shelf mounted platform that houses the OTEC power plant require an anodic or equivalent corrosion protection system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duffy, J.
1999-12-01
Students and faculty from an American University work with indigenous Peruvians to electrify their village and improve their quality of life. The remote village of Malvas in the Andes seems typical of many in Peru. The 500 Inca descendants have no electricity, no running water, one telephone and mud adobe houses. At a 10,000-foot (3,048 m) altitude, residents survive through subsistence farming. And this project might sound like a typical solar system installation--a system is donated, consultants install it, no one owns it and if something goes wrong, no one fixes it. The equipment ultimately helps no one and fewmore » learn from the experience. But two aspects of this project make it unique - the unusual level of communal sharing in the town and the design and installation of the solar system by students.« less
Design and installation of 3 photovoltaic village power systems in Tunisia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darkazalli, G.; Rangaraian, A.; Scudder, L.
1982-09-01
A joint program sponsored by the United States Agency for International Development (U.S.A.I.D.) and the government of Tunisia was initiated to study the feasibility of using photovoltaics to supply electricity to remote villages in Tunisia. U.S.A.I.D. selected the NASA Lewis Research Center to implement the installation of three photovoltaic systems in the Tunisian village of Hammam Biadha Sud. In a competitive procurement, NASA selected a team proposed by the Solar Power Corporation, TriSolar Corporation, Esso Standard Tunisie and Development Sciences, Inc. to design and install the systems and train the villagers in the use of photovoltaics. The Tunisian Government counterpartmore » to NASA, is STEG, the Tunisian electrical generation authority. An overview of the systems designs is presented in this paper.« less
Remotely Accessed Vehicle Traffic Management System
NASA Astrophysics Data System (ADS)
Al-Alawi, Raida
2010-06-01
The ever increasing number of vehicles in most metropolitan cities around the world and the limitation in altering the transportation infrastructure, led to serious traffic congestion and an increase in the travelling time. In this work we exploit the emergence of novel technologies such as the internet, to design an intelligent Traffic Management System (TMS) that can remotely monitor and control a network of traffic light controllers located at different sites. The system is based on utilizing Embedded Web Servers (EWS) technology to design a web-based TMS. The EWS located at each intersection uses IP technology for communicating remotely with a Central Traffic Management Unit (CTMU) located at the traffic department authority. Friendly GUI software installed at the CTMU will be able to monitor the sequence of operation of the traffic lights and the presence of traffic at each intersection as well as remotely controlling the operation of the signals. The system has been validated by constructing a prototype that resembles the real application.
Handels, H; Busch, C; Encarnação, J; Hahn, C; Kühn, V; Miehe, J; Pöppl, S I; Rinast, E; Rossmanith, C; Seibert, F; Will, A
1997-03-01
The software system KAMEDIN (Kooperatives Arbeiten und MEdizinische Diagnostik auf Innovativen Netzen) is a multimedia telemedicine system for exchange, cooperative diagnostics, and remote analysis of digital medical image data. It provides components for visualisation, processing, and synchronised audio-visual discussion of medical images. Techniques of computer supported cooperative work (CSCW) synchronise user interactions during a teleconference. Visibility of both local and remote cursor on the conference workstations facilitates telepointing and reinforces the conference partner's telepresence. Audio communication during teleconferences is supported by an integrated audio component. Furthermore, brain tissue segmentation with artificial neural networks can be performed on an external supercomputer as a remote image analysis procedure. KAMEDIN is designed as a low cost CSCW tool for ISDN based telecommunication. However it can be used on any TCP/IP supporting network. In a field test, KAMEDIN was installed in 15 clinics and medical departments to validate the systems' usability. The telemedicine system KAMEDIN has been developed, tested, and evaluated within a research project sponsored by German Telekom.
Terra Defender Cyber-Physical Wargame
2017-04-01
Army position unless so designated by other authorized documents. Citation of manufacturer’s or trade names does not constitute an official...person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control ...helped to achieve a better understanding of how Army supervisory control and data acquisition (SCADA) system and device security can be modeled and
Deception Based Intrusion Detection & Prevention for SCADA Environments -
the case of the Ukraine incident, the substations. So here's the idea. Number one, understand from idea is that one of the quotes that he made in that book, it's actually a famous quote, is that all security products. Case in point, I'll be at RSA in February. There's over 2,600 vendors at RSA all solving
2013-01-01
tremendously dangerous and sophisticated virus that successfully attacked a SCADA system is now available for free on the Internet, where one can find...security for the public and private sectors. To develop this capability, the Nation needs to undergo a paradigm shift on how it views the cyber... for communications and trade were extraordinarily important for the security and prosperity of Britain. Today, the security and prosperity of the
Analysis of synchronous and induction generators used at hydroelectric power plant
NASA Astrophysics Data System (ADS)
Diniş, C. M.; Popa, G. N.; lagăr, A.
2017-01-01
In this paper is presented an analysis of the operating electric generators (synchronous and induction) within a small capacity hydroelectric power plant. Such is treated the problem of monitoring and control hydropower plant using SCADA systems. Have been carried an experimental measurements in small hydropower plant for different levels of water in the lake and various settings of the operating parameters.
NASA Astrophysics Data System (ADS)
Gerilowski, Konstantin; Krautwurst, Sven; Thompson, David R.; Thorpe, Andrew K.; Kolyer, Richard W.; Jonsson, Haflidi; Krings, Thomas; Frankenberg, Christian; Horstjann, Markus; Leifer, Ira; Eastwood, Michael; Green, Robert O.; Vigil, Sam; Fladeland, Matthew; Schüttemeyer, Dirk; Burrows, John P.; Bovensmann, Heinrich
2016-04-01
The CO2 and MEthane EXperiment (COMEX) was a NASA and ESA funded campaign in support of the HyspIRI and CarbonSat mission definition activities. As a part of this effort, seven flights were performed between June 3 and September 4, 2014 with the Methane Airborne MAPper (MAMAP) remote sensing instrument (operated by the University of Bremen in cooperation with the German Research Centre for Geosciences - GFZ) over the Kern River, Kern Front, and Poso Creek Oil Fields located in California's San Joaquin Valley. MAMAP was installed for the flights aboard the Center for Interdisciplinary Remotely-Piloted Aircraft Studies (CIRPAS) Twin Otter aircraft, together with: a Picarro fast in-situ greenhouse gas (GHG) analyzer operated by the NASA Ames Research Center, ARC; a 5-hole turbulence probe; and an atmospheric measurement package operated by CIRPAS measuring aerosols, temperature, dew-point, and other atmospheric parameters. Three of the flights were accompanied by the Next Generation Airborne Visual InfraRed Imaging Spectrometer (AVIRIS-NG), operated by the Jet Propulsion Laboratory (JPL), California Institute of Technology, installed aboard a second Twin Otter aircraft. Large-scale, high-concentration CH4 plumes were detected by the MAMAP instrument over the fields and tracked over several kilometers. The spatial distribution of the MAMAP observed plumes was compared to high spatial resolution CH4 anomaly maps derived by AVIRIS-NG imaging spectroscopy data. Remote sensing data collected by MAMAP was used to infer CH4 emission rates and their distributions over the three fields. Aggregated emission estimates for the three fields were compared to aggregated emissions inferred by subsequent airborne in-situ validation measurements collected by the Picarro instrument. Comparison of remote sensing and in-situ flux estimates will be presented, demonstrating the ability of airborne remote sensing data to provide accurate emission estimates for concentrations above the detection limit. This opens new applications of airborne atmospheric remote sensing in the area of anthropogenic top-down emission monitoring as well as for atmospheric CH4 leakage monitoring during accidents like the Elgin blow-out (March 2012) in the North Sea or the recent Aliso Canyon gas leak incident (2015/2016) in California.
NASA Technical Reports Server (NTRS)
Dunlap, Timothy A.; Henry, Michael W.; Homyk, Raymond P.
2004-01-01
The figure presents selected views of a modular rake of 17 pitot probes for measuring both transient and steady-state pressures in a supersonic wind tunnel. In addition to pitot tubes visible in the figure, the probe modules contain (1) high-frequency dynamic-pressure transducers connected through wires to remote monitoring circuitry and (2) flow passages that lead to tubes that, in turn, lead to remote steady-state pressure transducers. Prior pitot-probe rakes were fabricated as unitary structures, into which the individual pitot probes were brazed. Repair or replacement of individual probes was difficult, costly, and time-consuming because (1) it was necessary to remove entire rakes in order to unbraze individual malfunctioning probes and (2) the heat of unbrazing a failed probe and of brazing a new probe in place could damage adjacent probes. In contrast, the modules in the present probe are designed to be relatively quickly and easily replaceable with no heating and, in many cases, without need for removal of the entire rake from the wind tunnel. To remove a malfunctioning probe, one first removes a screw-mounted V-cross-section cover that holds the probe and adjacent probes in place. Then one removes a screw-mounted cover plate to gain access to the steady-state pressure tubes and dynamicpressure wires. Next, one disconnects the tube and wires of the affected probe. Finally, one installs a new probe in the reverse of the aforementioned sequence. The wire connections can be made by soldering, but to facilitate removal and installation, they can be made via miniature plugs and sockets. The connections between the probe flow passages and the tubes leading to the remote pressure sensors can be made by use of any of a variety of readily available flexible tubes that can be easily pulled off and slid back on for removal and installation, respectively.
International Space Station (ISS)
2001-04-23
The STS-100 mission launched for the International Space Station (ISS) on April 19, 2001 as the sixth station assembly flight. Main objectives included the delivery and installation of the Canadian-built Space Station Remote Manipulator System (SSRMS), or Canadarm2, the installation of a UHF anterna for space-to-space communications for U.S. based space walks, and the delivery of supplies via the Italian Multipurpose Logistics Module (MPLM) "Raffaello". This is an STS-110 onboard photo of Astronaut James S. Voss, Expedition Two flight engineer, peering into the pressurized Mating Adapter (PMA-2) prior hatch opening. The picture was taken by one of the STS-100 crew members inside the PMA.
Scientific publishing in non industrialized countries: a pilot wireless internet project for Africa.
Azzi, Angelo
2005-01-01
There is general agreement that the internet is the major means of future scientific communication and education. However not everybody appreciates that the development of electronic communication in industrialized societies is not matched, even to a small extent, in developing countries. Several new technologies offer the potential for developing countries to provide connectivity. Terrestrial wireless and satellite technologies offer many advantages in that they do not require installation of wire-line networks. Satellite facilities can also be installed where communication is needed, even in remote and isolated areas, rather than waiting for terrestrial networks to be extended from the cities.
Analysis of the economics of photovoltaic-diesel-battery energy systems for remote applications
NASA Technical Reports Server (NTRS)
Brainard, W. A.
1983-01-01
Computer simulations were conducted to analyze the performance and operating cost of a photovoltaic energy source combined with a diesel generator system and battery storage. The simulations were based on the load demand profiles used for the design of an all photovoltaic energy system installed in the remote Papago Indian Village of Schuchuli, Arizona. Twenty year simulations were run using solar insolation data from Phoenix SOLMET tapes. Total energy produced, energy consumed, operation and maintenance costs were calculated. The life cycle and levelized energy costs were determined for a variety of system configurations (i.e., varying amounts of photovoltaic array and battery storage).
Instrumented Pick Detects Coal/Rock Interface
NASA Technical Reports Server (NTRS)
Wu, T.; Erkes, J. W.
1983-01-01
Instrumented pick installed on cutting drum of coal shearer for longwall mining measures cutting force with strain-gage-bridge load cell. Force signal transmitted to remote recorder. Transmitter located in base of pick assembly. Antenna located in shadow of rotating pick. Changes in characteristics of force signals from pick used to determine whether pick is cutting coal or rock.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-23
... Remote Sensing Network, a system of interconnected hydrophones installed in the marine environment of... unmitigable adverse impact on the availability of the species or stock(s) for subsistence uses (where relevant... use vibratory pile hammer for pile driving. Marine mammals are not expected to be injured (Level A...
DOT National Transportation Integrated Search
2014-08-01
This report describes the instrumentation and data acquisition for a continuous curved steel box-girder composite bridge in : Connecticut. The computer-based remote monitoring system was installed in 2001, with accelerometers, tilt meters and : tempe...
ERIC Educational Resources Information Center
Peterson, James N.; Hess, Herbert L.
An undergraduate capstone engineering design project now provides hydroelectric power to a remote wilderness location. Students investigated the feasibility of designing, building, and installing a 4kW hydroelectric system to satisfy the need for electric power to support the research and teaching functions of Taylor Ranch, a university facility…
30 CFR 250.1624 - Blowout prevention equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...
30 CFR 250.1624 - Blowout prevention equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...
30 CFR 250.1624 - Blowout prevention equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...
30 CFR 250.1624 - Blowout prevention equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... station and one BOP-control station on the rig floor; and (5) A choke line and a kill line each equipped with two full-opening valves and a choke manifold. One of the choke-line valves and one of the kill-line valves shall be remotely controlled except that a check valve may be installed on the kill line in...
The STD Site Operator. Satellite Technology Demonstration, Technical Report No. 0419.
ERIC Educational Resources Information Center
Braunstein, Jean
Intimately involved in any equipment system is the human factor. The people operating the equipment at the remote installations for the Satellite Technology Demonstration (STD) were different from paid employees or from private consumers. The STD site operators were paid only token fees; thus, they are best describd as having been motivated by the…
Development and evaluation of a water level proportional water sampler
NASA Astrophysics Data System (ADS)
Schneider, P.; Lange, A.; Doppler, T.
2013-12-01
We developed and adapted a new type of sampler for time-integrated, water level proportional water quality sampling (e.g. nutrients, contaminants and stable isotopes). Our samplers are designed for sampling small to mid-size streams based on the law of Hagen-Poiseuille, where a capillary (or a valve) limits the sampling aliquot by reducing the air flux out of a submersed plastic (HDPE) sampling container. They are good alternatives to battery-operated automated water samplers when working in remote areas, or at streams that are characterized by pronounced daily discharge variations such as glacier streams. We evaluated our samplers against standard automated water samplers (ISCO 2900 and ISCO 6712) during the snowmelt in the Black Forest and the Alps and tested them in remote glacial catchments in Iceland, Switzerland and Kyrgyzstan. The results clearly showed that our samplers are an adequate tool for time-integrated, water level proportional water sampling at remote test sites, as they do not need batteries, are relatively inexpensive, lightweight, and compact. They are well suited for headwater streams - especially when sampling for stable isotopes - as the sampled water is perfectly protected against evaporation. Moreover, our samplers have a reduced risk of icing in cold environments, as they are installed submersed in water, whereas automated samplers (typically installed outside the stream) may get clogged due to icing of hoses. Based on this study, we find these samplers to be an adequate replacement for automated samplers when time-integrated sampling or solute load estimates are the main monitoring tasks.
Microcomputer network for control of a continuous mining machine. Information circular/1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiffbauer, W.H.
1993-01-01
The paper details a microcomputer-based control and monitoring network that was developed in-house by the U.S. Bureau of Mines, and installed on a Joy 14 continuous mining machine. The network consists of microcomputers that are connected together via a single twisted pair cable. Each microcomputer was developed to provide a particular function in the control process. Machine-mounted microcomputers in conjunction with the appropriate sensors provide closed-loop control of the machine, navigation, and environmental monitoring. Off-the-machine microcomputers provide remote control of the machine, sensor status, and a connection to the network so that external computers can access network data and controlmore » the continuous mining machine. Although the network was installed on a Joy 14 continuous mining machine, its use extends beyond it. Its generic structure lends itself to installation onto most mining machine types.« less
Remote Sensing of the Environmental Impacts of Utility-Scale Solar Energy Plants
NASA Astrophysics Data System (ADS)
Edalat, Mohammad Masih
Solar energy has many environmental benefits compared with fossil fuels but solar farming can have environmental impacts especially during construction and development. Thus, in order to enhance environmental sustainability, it is imperative to understand the environmental impacts of utility-scale solar energy (USSE) plants. During recent decades, remote sensing techniques and geographic information systems have become standard techniques in environmental applications. In this study, the environmental impacts of USSE plants are investigated by analyzing changes to land surface characteristics using remote sensing. The surface characteristics studied include land cover, land surface temperature, and hydrological response whereas changes are mapped by comparing pre-, syn-, and post- construction conditions. In order to study the effects of USSE facilities on land cover, the changes in the land cover are measured and analyzed inside and around two USSE facilities. The principal component analysis (PCA), minimum noise fraction (MNF), and spectral mixture analysis (SMA) of remote sensing images are used to estimate the subpixel fraction of four land surface endmembers: high-albedo, low-albedo, shadow, and vegetation. The results revealed that USSE plants do not significantly impact land cover outside the plant boundary. However, land-cover radiative characteristics within the plant area are significantly affected after construction. During the construction phase, site preparation practices including shrub removal and land grading increase high-albedo and decrease low-albedo fractions. The thermal effects of USSE facilities are studied by the time series analysis of remote sensing land surface temperature (LST). A statistical trend analysis of LST, with seasonal trends removed is performed with a particular consideration of panel shadowing by analyzing sun angles for different times of year. The results revealed that the LST outside the boundary of the solar plant does not change, whereas it significantly decreases inside the plant at 10 AM after the construction. The decrease in LST mainly occurred in winters due to lower sun's altitude, which casts longer shadows on the ground. In order to study the hydrological impacts of PV plants, pre- and post-installation hydrological response over single-axis technology is compared. A theoretical reasoning is developed to explain flows under the influence of PV panels. Moreover, a distributed parametric hydrologic model is used to estimate runoff before and after the construction of PV plants. The results revealed that peak flow, peak flow time, and runoff volume alter after panel installation. After panel installation, peak flow decreases and is observed to shift in time, which depends on orientation. Likewise, runoff volume increases irrespective of panel orientation. The increase in the tilt angle of panel results in decrease in the peak flow, peak flow time, and runoff. This study provides an insight into the environmental impacts of USSE development using remote sensing. The research demonstrates that USSE plants are environmentally sustainable due to minimal impact on land cover and surface temperature in their vicinity. In addition, this research explains the role of rainfall shadowing on hydrological behavior at USSE plants.
2004-03-01
with MySQL . This choice was made because MySQL is open source. Any significant database engine such as Oracle or MS- SQL or even MS Access can be used...10 Figure 6. The DoD vs . Commercial Life Cycle...necessarily be interested in SCADA network security 13. MySQL (Database server) – This station represents a typical data server for a web page
Cyber: A Flexible Deterrent Option
2013-02-14
to come on when they throw a switch and other electrical appliances throughout the house to work without any commercial power interruption. For...power plants this means maintaining the electrical grid and the supervisory control and data acquisition (SCADA) systems at a reliable rate of “99.99999...on the grid.”36 The researchers “simply instructed it to make rapid changes in the electricity cycles that powered the equipment: fast, slow, fast
External Verification of SCADA System Embedded Controller Firmware
2012-03-01
microprocessor and read-only memory (ROM) or flash memory for storing firmware and control logic [5],[8]. A PLC typically has three software levels as shown in...implementing different firmware. Because PLCs are in effect a microprocessor device, an analysis of the current research on embedded devices is important...Electronics Engineers (IEEE) published a 15 best practices guide for firmware control on microprocessors [44]. IEEE suggests that microprocessors
2014-06-01
SCADA / ICS Cyber Test Lab initiated in 2013 Psychosocial – academic research exists,; opportunity for sharing and developing impact assessment...ecosystems and species at risk), accidents / system failure (rail; pipelines ; ferries CSSP strategy for the North Focus on regional l(and local) problem...Guidance; business planning; environmental scan; proposal evaluation; and performance measurement Program Risk Management – Guidelines for project
Improvement of the linear polarization resistance method for testing steel corrosion inhibitors
NASA Astrophysics Data System (ADS)
Faritov, A. T.; Rozhdestvenskii, Yu. G.; Yamshchikova, S. A.; Minnikhanova, E. R.; Tyusenkov, A. S.
2016-11-01
The linear polarization resistance method is used to improve the technique of corrosion control in liquid conducting according to GOST 9.514-99 (General Corrosion and Aging Protection System. Corrosion Inhibitors for Metals in Water Systems. Electrochemical Method of Determining the Protective Ability). Corrosion monitoring is shown to be performed by electronic devices with real-time data transfer to industrial controllers and SCADA systems.
NASA Astrophysics Data System (ADS)
Yu, Zhang; Xiaohui, Song; Jianfang, Li; Fei, Gao
2017-05-01
Cable overheating will lead to the cable insulation level reducing, speed up the cable insulation aging, even easy to cause short circuit faults. Cable overheating risk identification and warning is nessesary for distribution network operators. Cable overheating risk warning method based on impedance parameter estimation is proposed in the paper to improve the safty and reliability operation of distribution network. Firstly, cable impedance estimation model is established by using least square method based on the data from distribiton SCADA system to improve the impedance parameter estimation accuracy. Secondly, calculate the threshold value of cable impedance based on the historical data and the forecast value of cable impedance based on the forecasting data in future from distribiton SCADA system. Thirdly, establish risks warning rules library of cable overheating, calculate the cable impedance forecast value and analysis the change rate of impedance, and then warn the overheating risk of cable line based on the overheating risk warning rules library according to the variation relationship between impedance and line temperature rise. Overheating risk warning method is simulated in the paper. The simulation results shows that the method can identify the imedance and forecast the temperature rise of cable line in distribution network accurately. The result of overheating risk warning can provide decision basis for operation maintenance and repair.
NASA Astrophysics Data System (ADS)
Letizia, Stefano; Puccioni, Matteo; Zhan, Lu; Viola, Francesco; Camarri, Simone; Iungo, Giacomo Valerio
2017-11-01
Numerical simulations of wakes produced by utility-scale wind turbines still present challenges related to the variability of the atmospheric conditions and, in the most of the cases, the lack of information about the geometry and aerodynamic performance of the wind turbine blades. In order to overcome the mentioned difficulties, we propose a RANS solver for which turbine aerodynamic forcing and turbulence closure are calibrated through LiDAR and SCADA data acquired for an onshore wind farm. The wind farm under examination is located in North Texas over a relatively flat terrain. The experimental data are leveraged to maximize accuracy of the RANS predictions in terms of wake velocity field and power capture for different atmospheric stability conditions and settings of the wind turbines. The optimization of the RANS parameters is performed through an adjoint-RANS formulation and a gradient-based procedure. The optimally-tuned aerodynamic forcing and turbulence closure are then analyzed in order to investigate effects of the atmospheric stability on the evolution of wind turbine wakes and power performance. The proposed RANS solver has low computational costs comparable to those of wake engineering models, which make it a compelling tool for wind farm control and optimization. Acknowledgments: NSF I/UCRC WindSTAR IIP 1362033 and TACC.
Delivery and application of precise timing for a traveling wave powerline fault locator system
NASA Technical Reports Server (NTRS)
Street, Michael A.
1990-01-01
The Bonneville Power Administration (BPA) has successfully operated an in-house developed powerline fault locator system since 1986. The BPA fault locator system consists of remotes installed at cardinal power transmission line system nodes and a central master which polls the remotes for traveling wave time-of-arrival data. A power line fault produces a fast rise-time traveling wave which emanates from the fault point and propagates throughout the power grid. The remotes time-tag the traveling wave leading edge as it passes through the power system cardinal substation nodes. A synchronizing pulse transmitted via the BPA analog microwave system on a wideband channel sychronizes the time-tagging counters in the remote units to a different accuracy of better than one microsecond. The remote units correct the raw time tags for synchronizing pulse propagation delay and return these corrected values to the fault locator master. The master then calculates the power system disturbance source using the collected time tags. The system design objective is a fault location accuracy of 300 meters. BPA's fault locator system operation, error producing phenomena, and method of distributing precise timing are described.
Distributive, Non-destructive Real-time System and Method for Snowpack Monitoring
NASA Technical Reports Server (NTRS)
Frolik, Jeff (Inventor); Skalka, Christian (Inventor)
2013-01-01
A ground-based system that provides quasi real-time measurement and collection of snow-water equivalent (SWE) data in remote settings is provided. The disclosed invention is significantly less expensive and easier to deploy than current methods and less susceptible to terrain and snow bridging effects. Embodiments of the invention include remote data recovery solutions. Compared to current infrastructure using existing SWE technology, the disclosed invention allows more SWE sites to be installed for similar cost and effort, in a greater variety of terrain; thus, enabling data collection at improved spatial resolutions. The invention integrates a novel computational architecture with new sensor technologies. The invention's computational architecture is based on wireless sensor networks, comprised of programmable, low-cost, low-powered nodes capable of sophisticated sensor control and remote data communication. The invention also includes measuring attenuation of electromagnetic radiation, an approach that is immune to snow bridging and significantly reduces sensor footprints.
Assessment of radioisotope heaters for remote terrestrial applications
NASA Astrophysics Data System (ADS)
Uherka, Kenneth L.
This paper examines the feasibility of using radioisotope byproducts for special heating applications at remote sites in Alaska and other cold regions. The investigation included assessment of candidate radioisotope materials for heater applications, identification of the most promising cold-region applications, evaluation of key technical issues and implementation constraints, and development of conceptual heater designs for candidate applications. Strontium-90 (Sr-90) was selected as the most viable fuel for radioisotopic heaters used in terrestrial applications. Opportunities for the application of radioisotopic heaters were determined through site visits to representative Alaskan installations. Candidate heater applications included water storage tanks, sludge digesters, sewage lagoons, water piping systems, well-head pumping stations, emergency shelters, and fuel storage tank deicers. Radio-isotopic heaters for freeze-up protection of water storage tanks and for enhancement of biological waste treatment processes at remote sites were selected as the most promising applications.
Systems and methods for retaining and removing irradiation targets in a nuclear reactor
Runkle, Gary A.; Matsumoto, Jack T.; Dayal, Yogeshwar; Heinold, Mark R.
2015-12-08
A retainer is placed on a conduit to control movement of objects within the conduit in access-restricted areas. Retainers can prevent or allow movement in the conduit in a discriminatory fashion. A fork with variable-spacing between prongs can be a retainer and be extended or collapsed with respect to the conduit to change the size of the conduit. Different objects of different sizes may thus react to the fork differently, some passing and some being blocked. Retainers can be installed in inaccessible areas and allow selective movement in remote portions of conduit where users cannot directly interface, including below nuclear reactors. Position detectors can monitor the movement of objects through the conduit remotely as well, permitting engagement of a desired level of restriction and object movement. Retainers are useable in a variety of nuclear power plants and with irradiation target delivery, harvesting, driving, and other remote handling or robotic systems.
The Role of Atmospheric Measurements in Wind Power Statistical Models
NASA Astrophysics Data System (ADS)
Wharton, S.; Bulaevskaya, V.; Irons, Z.; Newman, J. F.; Clifton, A.
2015-12-01
The simplest wind power generation curves model power only as a function of the wind speed at turbine hub-height. While the latter is an essential predictor of power output, it is widely accepted that wind speed information in other parts of the vertical profile, as well as additional atmospheric variables including atmospheric stability, wind veer, and hub-height turbulence are also important factors. The goal of this work is to determine the gain in predictive ability afforded by adding additional atmospheric measurements to the power prediction model. In particular, we are interested in quantifying any gain in predictive ability afforded by measurements taken from a laser detection and ranging (lidar) instrument, as lidar provides high spatial and temporal resolution measurements of wind speed and direction at 10 or more levels throughout the rotor-disk and at heights well above. Co-located lidar and meteorological tower data as well as SCADA power data from a wind farm in Northern Oklahoma will be used to train a set of statistical models. In practice, most wind farms continue to rely on atmospheric measurements taken from less expensive, in situ instruments mounted on meteorological towers to assess turbine power response to a changing atmospheric environment. Here, we compare a large suite of atmospheric variables derived from tower measurements to those taken from lidar to determine if remote sensing devices add any competitive advantage over tower measurements alone to predict turbine power response.
Substation alarm multiplexing system (SAMS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
ElBadaly, H.; Gaughan, J.; Ward, G.
1996-03-01
This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creekmore » substation in the Bronx for the purpose of a three month field evaluation.« less
The Business Case for Fuel Cells: Delivering Sustainable Value
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtin, Sandra; Gangi, Jennifer
This report, written and compiled by Argonne National Laboratory and the Fuel Cell and Hydrogen Energy Association with support from the Fuel Cell Technologies Office, provides an overview of private sector fuel cell installations at U.S. businesses as of December 31, 2016. Over the past few decades, hundreds of thousands of fuel cells have been installed around the world, for primary or backup power, as well as in various other applications including portable and emergency backup power. Fuel cells have also been deployed in other applications such as heat and electricity for homes and apartments, material handling, passenger vehicles, buses,more » and remote, off-grid sites.« less
Astronaut Voss Peers Into Pressurized Mating Adapter (PMA)
NASA Technical Reports Server (NTRS)
2001-01-01
The STS-100 mission launched for the International Space Station (ISS) on April 19, 2001 as the sixth station assembly flight. Main objectives included the delivery and installation of the Canadian-built Space Station Remote Manipulator System (SSRMS), or Canadarm2, the installation of a UHF anterna for space-to-space communications for U.S. based space walks, and the delivery of supplies via the Italian Multipurpose Logistics Module (MPLM) 'Raffaello'. This is an STS-110 onboard photo of Astronaut James S. Voss, Expedition Two flight engineer, peering into the pressurized Mating Adapter (PMA-2) prior hatch opening. The picture was taken by one of the STS-100 crew members inside the PMA.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-03
... remote disaster recovery sites only). Option 1: Dual 56kb lines (one for redundancy) and $1,000/month... 128kb. Bandwidth Enhancement Fee (for T1 subscribers only): Per 64kb increase above 128kb T1 base... Enhancement software enhancement. Fee) plus 20%. Installation Fee $2,000 per site for dual hubs and routers...
NREL Research Garners Three Prestigious R&D 100 Awards | News | NREL
, SkyFuel, to create a ground-breaking and low-cost system for utility-sized power generation. The SkyTrough installation costs into competition with gas-fired power plants. NREL shares this award with SkyFuel, Inc. NREL -film lithium microbattery. Its ideal applications are remote wireless sensors, smart homes, smart cars
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zvi H. Meiksin
A temporary installation of Transtek's in-mine communications system in the Lake Lynn mine was used in the mine rescue training programs offered by NIOSH in April and May 2002. We developed and implemented a software program that permits point-to-point data transmission through our in-mine system. We also developed a wireless data transceiver for use in a PLC (programmed logic controller) to remotely control long-wall mining equipment.
Design of a seismo-acoustic station for Antarctica.
Contrafatto, Danilo; Fasone, Rosario; Ferro, Angelo; Larocca, Graziano; Laudani, Giuseppe; Rapisarda, Salvatore; Scuderi, Luciano; Zuccarello, Luciano; Privitera, Eugenio; Cannata, Andrea
2018-04-01
In recent years, seismological studies in Antarctica have contributed plenty of new knowledge in many fields of earth science. Moreover, acoustic investigations are now also considered a powerful tool that provides insights for many different objectives, such as analyses of regional climate-related changes and studies of volcanic degassing and explosive activities. However, installation and maintenance of scientific instrumentation in Antarctica can be really challenging. Indeed, the instruments have to face the most extreme climate on the planet. They must be tolerant of very low temperatures and robust enough to survive strong winds. Moreover, one of the most critical tasks is powering a remote system year-round at polar latitudes. In this work, we present a novel seismo-acoustic station designed to work reliably in polar regions. To enable year-round seismo-acoustic data collection in such a remote, extreme environment, a hybrid powering system is used, integrating solar panels, a wind generator, and batteries. A power management system was specifically developed to either charge the battery bank or divert energy surplus to warm the enclosure or release the excess energy to the outside environment. Finally, due to the prohibitive environmental conditions at most Antarctic installation sites, the station was designed to be deployed quickly.
Design of a seismo-acoustic station for Antarctica
NASA Astrophysics Data System (ADS)
Contrafatto, Danilo; Fasone, Rosario; Ferro, Angelo; Larocca, Graziano; Laudani, Giuseppe; Rapisarda, Salvatore; Scuderi, Luciano; Zuccarello, Luciano; Privitera, Eugenio; Cannata, Andrea
2018-04-01
In recent years, seismological studies in Antarctica have contributed plenty of new knowledge in many fields of earth science. Moreover, acoustic investigations are now also considered a powerful tool that provides insights for many different objectives, such as analyses of regional climate-related changes and studies of volcanic degassing and explosive activities. However, installation and maintenance of scientific instrumentation in Antarctica can be really challenging. Indeed, the instruments have to face the most extreme climate on the planet. They must be tolerant of very low temperatures and robust enough to survive strong winds. Moreover, one of the most critical tasks is powering a remote system year-round at polar latitudes. In this work, we present a novel seismo-acoustic station designed to work reliably in polar regions. To enable year-round seismo-acoustic data collection in such a remote, extreme environment, a hybrid powering system is used, integrating solar panels, a wind generator, and batteries. A power management system was specifically developed to either charge the battery bank or divert energy surplus to warm the enclosure or release the excess energy to the outside environment. Finally, due to the prohibitive environmental conditions at most Antarctic installation sites, the station was designed to be deployed quickly.
Meter reading for smaller customers in an open-access environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-05-01
As the ability to buy gas and transportation services directly from suppliers becomes available to small commercial and residential customers, local distribution companies (LDCs) are evaluating how to measure and track their consumption. The LDCs often measure the gas use of large commercial and industrial customers with remote, automated meter-reading (AMR) devices, many of which provide real-time data. The utility can justify the expense of installing these devices because of the customers` considerable gas consumption. But for customers who already contribute very little to margins, AMR investments by LDCs are more problematic. The paper discusses some options for remote meteringmore » and forecasts future trends in the industry.« less
Power components for the Space Station 20-kHz power distribution system
NASA Technical Reports Server (NTRS)
Renz, David D.
1988-01-01
Since 1984, NASA Lewis Research Center was developing high power, high frequency space power components as part of The Space Station Advanced Development program. The purpose of the Advanced Development program was to accelerate existing component programs to ensure their availability for use on the Space Station. These components include a rotary power transfer device, remote power controllers, remote bus isolators, high power semiconductor, a high power semiconductor package, high frequency-high power cable, high frequency-high power connectors, and high frequency-high power transformers. All the components were developed to the prototype level and will be installed in the Lewis Research Center Space Station power system test bed.
Power components for the space station 20-kHz power distribution system
NASA Technical Reports Server (NTRS)
Renz, David D.
1988-01-01
Since 1984, NASA Lewis Research Center was developing high power, high frequency space power components as part of The Space Station Advanced Development program. The purpose of The Advanced Development program was to accelerate existing component programs to ensure their availability for use on the Space Station. These components include a rotary power transfer device, remote power controllers, remote bus isolators, high power semiconductor, a high power semiconductor package, high frequency-high power cable, high frequency-high power connectors, and high frequency-high power transformers. All the components were developed to the prototype level and will be installed in the Lewis Research Center Space Station power system test bed.
Motor current signature analysis method for diagnosing motor operated devices
Haynes, Howard D.; Eissenberg, David M.
1990-01-01
A motor current noise signature analysis method and apparatus for remotely monitoring the operating characteristics of an electric motor-operated device such as a motor-operated valve. Frequency domain signal analysis techniques are applied to a conditioned motor current signal to distinctly identify various operating parameters of the motor driven device from the motor current signature. The signature may be recorded and compared with subsequent signatures to detect operating abnormalities and degradation of the device. This diagnostic method does not require special equipment to be installed on the motor-operated device, and the current sensing may be performed at remote control locations, e.g., where the motor-operated devices are used in accessible or hostile environments.
Optical assessment of nonimaging concentrators.
Timinger, A; Kribus, A; Ries, H; Smith, T; Walther, M
2000-11-01
An optical measurement method for nonimaging radiation concentrators is proposed. A Lambertian light source is placed in the exit aperture of the concentrator. Looking into the concentrator's entrance aperture from a remote position, one can photograph the transmission patterns. The patterns show the transmission of radiation through the concentrator with the full resolution of the four-dimensional phase space of geometric optics. By matching ray-tracing simulations to the measurement, one can achieve detailed and accurate information about the geometry of the concentrator. This is a remote, noncontact measurement and can be performed in situ for installed concentrators. Additional information regarding small-scale reflector waviness and surface reflectivity can also be obtained from the same measurement with additional analysis.
Optical frequency transfer via a 660 km underground fiber link using a remote Brillouin amplifier.
Raupach, S M F; Koczwara, A; Grosche, G
2014-11-03
In long-distance, optical continuous-wave frequency transfer via fiber, remote bidirectional Er³ ⁺ -doped fiber amplifiers are commonly used to mitigate signal attenuation. We demonstrate for the first time the ultrastable transfer of an optical frequency using a remote fiber Brillouin amplifier, placed in a server room along the link. Using it as the only means of remote amplification, on a 660 km loop of installed underground fiber we bridge distances of 250 km and 160 km between amplifications. Over several days of uninterrupted measurement, we find an instability of the frequency transfer (Allan deviation of Λ-weighted data with 1 s gate time) of around 1 × 10(-19) and less for averaging times longer than 3000 s. The modified Allan deviation reaches 3 × 10(-19) at an averaging time of 100 s. Beyond 100 s it follows the interferometer noise floor, and for averaging times longer than 1000 s the modified Allan deviation is in the 10(-20) range. A conservative value of the overall accuracy is 1 × 10(-19)
NASA Astrophysics Data System (ADS)
Krause, H. F.; Deveney, E. F.; Jones, N. L.; Vane, C. R.; Datz, S.; Knudsen, H.; Grafström, P.; Schuch, R.
1997-04-01
Recent atomic physics studies involving ultrarelativistic Pb ions required solid target positioners, scintillators, and a sophisticated data acquisition and control system placed in a remote location at the CERN Super Proton Synchrotron near Geneva, Switzerland. The apparatus, installed in a high-radiation zone underground, had to (i) function for months, (ii) automatically respond to failures such as power outages and particle-induced computer upsets, and (iii) communicate with the outside world via a telephone line. The heart of the apparatus developed was an Apple Macintosh-based CAMAC system that answered the telephone and interpreted and executed remote control commands that (i) sensed and set targets, (ii) controlled voltages and discriminator levels for scintillators, (iii) modified data acquisition hardware logic, (iv) reported control information, and (v) automatically synchronized data acquisition to the CERN spill cycle via a modem signal and transmitted experimental data to a remote computer. No problems were experienced using intercontinental telephone connections at 1200 baud. Our successful "virtual laboratory" approach that uses off-the-shelf electronics is generally adaptable to more conventional bench-type experiments.
An embedded wireless system for remote monitoring of bridges
NASA Astrophysics Data System (ADS)
Harms, T.; Bastianini, F.; Sedigh Sarvestani, S.
2008-03-01
This paper describes an autonomous embedded system for remote monitoring of bridges. Salient features of the system include ultra-low power consumption, wireless communication of data and alerts, and incorporation of embedded sensors that monitor various indicators of the structural health of a bridge, while capturing the state of its surrounding environment. Examples include water level, temperature, vibration, and acoustic emissions. Ease of installation, physical robustness, remote maintenance and calibration, and autonomous data communication make the device a self-contained solution for remote monitoring of structural health. The system addresses shortcomings present in centralized structural health monitoring systems, particularly their reliance on a laptop or handheld computer. The system has been field-tested to verify the accuracy of the collected data and dependability of communication. The sheer volume of data collected, and the regularity of its collection can enable accurate and precise assessment of the health of a bridge, guiding maintenance efforts and providing early warning of potentially dangerous events. In this paper, we present a detailed breakdown of the system's power requirements and the results of the initial field test.
A computer network with scada and case tools for on-line process control in greenhouses
NASA Astrophysics Data System (ADS)
Gieling, Th. H.; van Meurs, W. Th. M.; Janssen, H. J. J.
Climate control computers in greenhouses are used to control heating and ventilation, supply water and dilute and dispense nutrients. They integrate models into optimally controlled systems. This paper describes how information technology, as in use in other sectors of industry, is applied to greenhouse control. The introduction of modern software and hardware concepts in horticulture adds power and extra opportunities to climate control in greenhouses.
Rotary Kiln Gasification of Solid Waste for Base Camps
2017-10-02
cup after full day run 3.3 Feedstock Handling System Garbage bags containing waste feedstock are placed into feed bin FB-101. Ram feeder RF-102...Environmental Science and Technology using the Factory Talk SCADA software running on a laptop computer. A wireless Ethernet router that is located within the...pyrolysis oil produced required consistent draining from the system during operation and became a liquid waste disposal problem. A 5-hour test run could
A computer network with SCADA and case tools for on-line process control in greenhouses.
Gieling ThH; van Meurs WTh; Janssen, H J
1996-01-01
Climate control computers in greenhouses are used to control heating and ventilation, supply water and dilute and dispense nutrients. They integrate models into optimally controlled systems. This paper describes how information technology, as in use in other sectors of industry, is applied to greenhouse control. The introduction of modern software and hardware concepts in horticulture adds power and extra oppurtunities to climate contol in greenhouses.
America’s Achilles Heel: Defense Against High-altitude Electromagnetic Pulse-policy vs. Practice
2014-12-12
Directives SCADA Supervisory Control and Data Acquisition Systems SHIELD Act Secure High-voltage Infrastructure for Electricity from Lethal Damage Act...take place, it is important to understand the effects of the components of EMP from a high-altitude nuclear detonation. The requirements for shielding ...Mass Ejection (CME). A massive, bubble-shaped burst of plasma expanding outward from the Sun’s corona, in which large amounts of superheated
In-home virtual reality videogame telerehabilitation in adolescents with hemiplegic cerebral palsy.
Golomb, Meredith R; McDonald, Brenna C; Warden, Stuart J; Yonkman, Janell; Saykin, Andrew J; Shirley, Bridget; Huber, Meghan; Rabin, Bryan; Abdelbaky, Moustafa; Nwosu, Michelle E; Barkat-Masih, Monica; Burdea, Grigore C
2010-01-01
Golomb MR, McDonald BC, Warden SJ, Yonkman J, Saykin AJ, Shirley B, Huber M, Rabin B, AbdelBaky M, Nwosu ME, Barkat-Masih M, Burdea GC. In-home virtual reality videogame telerehabilitation in adolescents with hemiplegic cerebral palsy. To investigate whether in-home remotely monitored virtual reality videogame-based telerehabilitation in adolescents with hemiplegic cerebral palsy can improve hand function and forearm bone health, and demonstrate alterations in motor circuitry activation. A 3-month proof-of-concept pilot study. Virtual reality videogame-based rehabilitation systems were installed in the homes of 3 participants and networked via secure Internet connections to the collaborating engineering school and children's hospital. Adolescents (N=3) with severe hemiplegic cerebral palsy. Participants were asked to exercise the plegic hand 30 minutes a day, 5 days a week using a sensor glove fitted to the plegic hand and attached to a remotely monitored videogame console installed in their home. Games were custom developed, focused on finger movement, and included a screen avatar of the hand. Standardized occupational therapy assessments, remote assessment of finger range of motion (ROM) based on sensor glove readings, assessment of plegic forearm bone health with dual-energy x-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT), and functional magnetic resonance imaging (fMRI) of hand grip task. All 3 adolescents showed improved function of the plegic hand on occupational therapy testing, including increased ability to lift objects, and improved finger ROM based on remote measurements. The 2 adolescents who were most compliant showed improvements in radial bone mineral content and area in the plegic arm. For all 3 adolescents, fMRI during grip task contrasting the plegic and nonplegic hand showed expanded spatial extent of activation at posttreatment relative to baseline in brain motor circuitry (eg, primary motor cortex and cerebellum). Use of remotely monitored virtual reality videogame telerehabilitation appears to produce improved hand function and forearm bone health (as measured by DXA and pQCT) in adolescents with chronic disability who practice regularly. Improved hand function appears to be reflected in functional brain changes. Copyright (c) 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Contributing opportunistic resources to the grid with HTCondor-CE-Bosco
NASA Astrophysics Data System (ADS)
Weitzel, Derek; Bockelman, Brian
2017-10-01
The HTCondor-CE [1] is the primary Compute Element (CE) software for the Open Science Grid. While it offers many advantages for large sites, for smaller, WLCG Tier-3 sites or opportunistic clusters, it can be a difficult task to install, configure, and maintain the HTCondor-CE. Installing a CE typically involves understanding several pieces of software, installing hundreds of packages on a dedicated node, updating several configuration files, and implementing grid authentication mechanisms. On the other hand, accessing remote clusters from personal computers has been dramatically improved with Bosco: site admins only need to setup SSH public key authentication and appropriate accounts on a login host. In this paper, we take a new approach with the HTCondor-CE-Bosco, a CE which combines the flexibility and reliability of the HTCondor-CE with the easy-to-install Bosco. The administrators of the opportunistic resource are not required to install any software: only SSH access and a user account are required from the host site. The OSG can then run the grid-specific portions from a central location. This provides a new, more centralized, model for running grid services, which complements the traditional distributed model. We will show the architecture of a HTCondor-CE-Bosco enabled site, as well as feedback from multiple sites that have deployed it.
NASA Astrophysics Data System (ADS)
Agoritsas, V.; Beck, F.; Benincasa, G. P.; Bovigny, J. P.
1986-06-01
This paper describes a new beam loss monitor system which has been installed in the PS and PSB machines, replacing an earlier system. The new system is controlled by a microprocessor which can operate independently of the accelerator control system, though setting up and central display are usually done remotely, using the standard control system facilities.
NASA Technical Reports Server (NTRS)
Stokes, J. W.; Pruett, E. C.
1980-01-01
A cost algorithm for predicting assembly costs for large space structures is given. Assembly scenarios are summarized which describe the erection, deployment, and fabrication tasks for five large space structures. The major activities that impact total costs for structure assembly from launch through deployment and assembly to scientific instrument installation and checkout are described. Individual cost elements such as assembly fixtures, handrails, or remote minipulators are also presented.
West Europe Report, Science and Technology
1986-01-16
Nicolas Rousseaux; ZERO UN INFORMATION HEBDO, 30 Sep 85) 93 TECHNOLOGY TRANSFER Briefs Renault Equipment to USSR 96 c - 16 January 1986 AEROSPACE...personnel and has a capacity of 200 persons. From the launch center, where monitoring and command systems are installed, the start up of the remote...supplying of propellants and fluids and hookup of monitoring and control systems -preparation for launch: countdown and launch -possible erection and
Solar Refrigerator/Freezers For Vaccines
NASA Technical Reports Server (NTRS)
Ratajczak, Anthony F.
1988-01-01
Report presents results of field tests of solar-cell-powered refrigerator/freezers for vaccines. Covers following topics: explanation of project; descriptions of refrigerator/freezer systems; account of installation experiences; performance data for 22 systems for which field-test data reported; summary of operational reliability; comments of users of some systems tested; and recommendations for design and future use. Photovoltaic systems store vaccines in remote regions where powerlines unavailable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bohachek, Randolph Charles
2015-09-01
The Advanced Test Reactor (ATR; TRA-670), which is located in the ATR Complex at Idaho National Laboratory, was constructed in the 1960s for the purpose of irradiating reactor fuels and materials. Other irradiation services, such as radioisotope production, are also performed at ATR. While ATR is safely fulfilling current mission requirements, assessments are continuing. These assessments intend to identify areas to provide defense–in-depth and improve safety for ATR. One of the assessments performed by an independent group of nuclear industry experts recommended that a remote accident management capability be provided. The report stated that: “contemporary practice in commercial power reactorsmore » is to provide a remote shutdown station or stations to allow shutdown of the reactor and management of long-term cooling of the reactor (i.e., management of reactivity, inventory, and cooling) should the main control room be disabled (e.g., due to a fire in the control room or affecting the control room).” This project will install remote reactor monitoring and management capabilities for ATR. Remote capabilities will allow for post scram reactor management and monitoring in the event the main Reactor Control Room (RCR) must be evacuated.« less
NASA Astrophysics Data System (ADS)
Chen, Jin; Wang, Yifan; Wang, Xuelei; Wang, Yuehong; Hu, Rui
2017-01-01
Combine harvester usually works in sparsely populated areas with harsh environment. In order to achieve the remote real-time video monitoring of the working state of combine harvester. A remote video monitoring system based on ARM11 and embedded Linux is developed. The system uses USB camera for capturing working state video data of the main parts of combine harvester, including the granary, threshing drum, cab and cut table. Using JPEG image compression standard to compress video data then transferring monitoring screen to remote monitoring center over the network for long-range monitoring and management. At the beginning of this paper it describes the necessity of the design of the system. Then it introduces realization methods of hardware and software briefly. And then it describes detailedly the configuration and compilation of embedded Linux operating system and the compiling and transplanting of video server program are elaborated. At the end of the paper, we carried out equipment installation and commissioning on combine harvester and then tested the system and showed the test results. In the experiment testing, the remote video monitoring system for combine harvester can achieve 30fps with the resolution of 800x600, and the response delay in the public network is about 40ms.
Cowan, J; Michel, C; Manhiça, I; Mutaquiha, C; Monivo, C; Saize, D; Beste, J; Creswell, J; Codlin, A J; Gloyd, S
2016-03-01
Electronic diagnostic tests, such as the Xpert® MTB/RIF assay, are being implemented in low- and middle-income countries (LMICs). However, timely information from these tests available via remote monitoring is underutilized. The failure to transmit real-time, actionable data to key individuals such as clinicians, patients, and national monitoring and evaluation teams may negatively impact patient care. To describe recently developed applications that allow for real-time, remote monitoring of Xpert results, and initial implementation of one of these products in central Mozambique. In partnership with the Mozambican National Tuberculosis Program, we compared three different remote monitoring tools for Xpert and selected one, GxAlert, to pilot and evaluate at five public health centers in Mozambique. GxAlert software was successfully installed on all five Xpert computers, and test results are now uploaded daily via a USB internet modem to a secure online database. A password-protected web-based interface allows real-time analysis of test results, and 1200 positive tests for tuberculosis generated 8000 SMS result notifications to key individuals. Remote monitoring of diagnostic platforms is feasible in LMICs. While promising, this effort needs to address issues around patient data ownership, confidentiality, interoperability, unique patient identifiers, and data security.
Preventing a Cyber Dresden: How the Evolution of Air Power can Guide the Evolution of Cyber
2011-06-01
24 Paul Cornish, On Cyber Warfare, (London: RUSI, 2010), 1. 25 CNN‟s footage of Project Aurora, the staged demonstration of SCADA vulnerabilities... Paul McHugh, “Striving for Coherence: Psychiatry‟s Efforts Over Classification”, The Journal of American Medical Association, no.293 (2005):2526-2528...Randall Wakelam, The Science of Bombing: Operational Research in RAF Bomber Command (Toronto: University of Toronto Press, 2009), 157-182 and Dana
Secure Control Systems for the Energy Sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Rhett; Campbell, Jack; Hadley, Mark
2012-03-31
Schweitzer Engineering Laboratories (SEL) will conduct the Hallmark Project to address the need to reduce the risk of energy disruptions because of cyber incidents on control systems. The goals is to develop solutions that can be both applied to existing control systems and designed into new control systems to add the security measures needed to mitigate energy network vulnerabilities. The scope of the Hallmark Project contains four primary elements: 1. Technology transfer of the Secure Supervisory Control and Data Acquisition (SCADA) Communications Protocol (SSCP) from Pacific Northwest National Laboratories (PNNL) to Schweitzer Engineering Laboratories (SEL). The project shall use thismore » technology to develop a Federal Information Processing Standard (FIPS) 140-2 compliant original equipment manufacturer (OEM) module to be called a Cryptographic Daughter Card (CDC) with the ability to directly connect to any PC enabling that computer to securely communicate across serial to field devices. Validate the OEM capabilities with another vendor. 2. Development of a Link Authenticator Module (LAM) using the FIPS 140-2 validated Secure SCADA Communications Protocol (SSCP) CDC module with a central management software kit. 3. Validation of the CDC and Link Authenticator modules via laboratory and field tests. 4. Creation of documents that record the impact of the Link Authenticator to the operators of control systems and on the control system itself. The information in the documents can assist others with technology deployment and maintenance.« less
Chen, Qian; Abercrombie, Robert K; Sheldon, Frederick T.
2015-09-23
Industrial Control Systems (ICS) are commonly used in industries such as oil and natural gas, transportation, electric, water and wastewater, chemical, pharmaceutical, pulp and paper, food and beverage, as well as discrete manufacturing (e.g., automotive, aerospace, and durable goods.) SCADA systems are generally used to control dispersed assets using centralized data acquisition and supervisory control.Originally, ICS implementations were susceptible primarily to local threats because most of their components were located in physically secure areas (i.e., ICS components were not connected to IT networks or systems). The trend toward integrating ICS systems with IT networks (e.g., efficiency and the Internet ofmore » Things) provides significantly less isolation for ICS from the outside world thus creating greater risk due to external threats. Albeit, the availability of ICS/SCADA systems is critical to assuring safety, security and profitability. Such systems form the backbone of our national cyber-physical infrastructure.Herein, we extend the concept of mean failure cost (MFC) to address quantifying availability to harmonize well with ICS security risk assessment. This new measure is based on the classic formulation of Availability combined with Mean Failure Cost (MFC). Finally, the metric offers a computational basis to estimate the availability of a system in terms of the loss that each stakeholder stands to sustain as a result of security violations or breakdowns (e.g., deliberate malicious failures).« less
Estimating Rooftop Suitability for PV: A Review of Methods, Patents, and Validation Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melius, J.; Margolis, R.; Ong, S.
2013-12-01
A number of methods have been developed using remote sensing data to estimate rooftop area suitable for the installation of photovoltaics (PV) at various geospatial resolutions. This report reviews the literature and patents on methods for estimating rooftop-area appropriate for PV, including constant-value methods, manual selection methods, and GIS-based methods. This report also presents NREL's proposed method for estimating suitable rooftop area for PV using Light Detection and Ranging (LiDAR) data in conjunction with a GIS model to predict areas with appropriate slope, orientation, and sunlight. NREL's method is validated against solar installation data from New Jersey, Colorado, and Californiamore » to compare modeled results to actual on-the-ground measurements.« less
MBS grappled to the Canadarm2 SSRMS during STS-111 UF-2 installation OPS on the ISS truss structure
2002-06-10
STS111-E-5139 (10 June 2002) --- Backdropped by the blackness of space and Earths horizon, the Mobile Remote Servicer Base System (MBS) is moved by the Canadarm2 for installation on the International Space Station (ISS). Astronauts Peggy A. Whitson, Expedition Five flight engineer, and Carl E. Walz, Expedition Four flight engineer, attached the MBS to the Mobile Transporter on the S0 (S-zero) Truss at 8:03 a.m. (CDT) on June 10, 2002. The MBS is an important part of the stations Mobile Servicing System, which will allow the stations robotic arm to travel the length of the station to perform construction tasks.
MBS grappled to the Canadarm2 SSRMS during STS-111 UF-2 installation OPS on the ISS truss structure
2002-06-10
STS111-E-5142 (10 June 2002) --- Backdropped by the blackness of space and Earths horizon, the Mobile Remote Servicer Base System (MBS) is moved by the Canadarm2 for installation on the International Space Station (ISS). Astronauts Peggy A. Whitson, Expedition Five flight engineer, and Carl E. Walz, Expedition Four flight engineer, attached the MBS to the Mobile Transporter on the S0 (S-zero) Truss at 8:03 a.m. (CDT) on June 10, 2002. The MBS is an important part of the stations Mobile Servicing System, which will allow the stations robotic arm to travel the length of the station to perform construction tasks.
NASA Astrophysics Data System (ADS)
Kaldellis, J. K.; Kostas, P.; Filios, A.
2006-07-01
Autonomous wind power systems are among the most interesting and environmentally friendly technological solutions for the electrification of remote consumers. In many cases, however, the battery contribution to the initial or the total operational cost is found to be dominant, discouraging further penetration of the available wind resource. This is basically the case for areas possessing a medium-low wind potential. On the other hand, several isolated consumers are located in regions having the regular benefit of an abundant and reliable solar energy supply. In this context the present study investigates the possibility of reducing the battery size of a stand-alone wind power installation by incorporating a small photovoltaic generator. For this purpose an integrated energy production installation based exclusively on renewable energy resources is hereby proposed. Subsequently a new numerical algorithm is developed that is able to estimate the appropriate dimensions of a similar system. According to the results obtained by long-term experimental measurements, the introduction of the photovoltaic panels considerably improves the operational and financial behaviour of the complete installation owing to the imposed significant battery capacity diminution. Copyright
Assessing the Future of Distributed Wind: Opportunities for Behind-the-Meter Projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lantz, Eric; Sigrin, Benjamin; Gleason, Michael
2016-11-01
Wind power is one of the fastest growing sources of new electricity generation in the United States. Cumulative installed capacity was more than 74,000 megawatts (MW) at year-end 2015 and wind power supplied 4.7% of total 2015 U.S. electricity generation. Despite the growth of the wind power industry, the distributed wind market has remained limited. Cumulative installations of distributed wind through 2015 totaled 934 MW. This first-of-a-kind exploratory analysis characterizes the future opportunity for behind-the-meter distributed wind, serving primarily rural or suburban homes, farms, and manufacturing facilities. This work focuses only on the grid-connected, behind-the-meter subset of the broader distributedmore » wind market. We estimate this segment to be approximately half of the 934 MW of total installed distributed wind capacity at year-end 2015. Potential from other distributed wind market segments including systems installed in front of the meter (e.g., community wind) and in remote, off-grid locations is not assessed in this analysis and therefore, would be additive to results presented here. These other distributed wind market segments are not considered in this initial effort because of their relatively unique economic and market attributes.« less
System design package for the solar heating and cooling central data processing system
NASA Technical Reports Server (NTRS)
1978-01-01
The central data processing system provides the resources required to assess the performance of solar heating and cooling systems installed at remote sites. These sites consist of residential, commercial, government, and educational types of buildings, and the solar heating and cooling systems can be hot-water, space heating, cooling, and combinations of these. The instrumentation data associated with these systems will vary according to the application and must be collected, processed, and presented in a form which supports continuity of performance evaluation across all applications. Overall software system requirements were established for use in the central integration facility which transforms raw data collected at remote sites into performance evaluation information for assessing the performance of solar heating and cooling systems.
Remote-area health care delivery through space technology - STARPAHC
NASA Technical Reports Server (NTRS)
Belasco, N.; Johnston, R. S.; Stonesifer, J. C.; Pool, S. L.
1977-01-01
A joint NASA/HEW project called Space Technology Applied to Rural Papage Advanced Health Care (STARPAHC) has been developed to deliver quality health care to inhabitants of remote geographical areas. The system consists of a hospital-based support control center, a fixed clinic, a mobile clinic, and a referral center with access to specialists via television links to the control center. A strategically located relay station routes television, voice, and data transmissions between system elements. A model system has been installed on the Papage Indian Reservation in Arizona, and is undergoing a 2-year evaluation. The system has been shown to be both effective and cost-efficient, and applications of the concept are planned for future manned spacecraft flights.
Plugin free remote visualization in the browser
NASA Astrophysics Data System (ADS)
Tamm, Georg; Slusallek, Philipp
2015-01-01
Today, users access information and rich media from anywhere using the web browser on their desktop computers, tablets or smartphones. But the web evolves beyond media delivery. Interactive graphics applications like visualization or gaming become feasible as browsers advance in the functionality they provide. However, to deliver large-scale visualization to thin clients like mobile devices, a dedicated server component is necessary. Ideally, the client runs directly within the browser the user is accustomed to, requiring no installation of a plugin or native application. In this paper, we present the state-of-the-art of technologies which enable plugin free remote rendering in the browser. Further, we describe a remote visualization system unifying these technologies. The system transfers rendering results to the client as images or as a video stream. We utilize the upcoming World Wide Web Consortium (W3C) conform Web Real-Time Communication (WebRTC) standard, and the Native Client (NaCl) technology built into Chrome, to deliver video with low latency.
An Integrated Chemical Reactor-Heat Exchanger Based on Ammonium Carbamate (POSTPRINT)
2012-10-01
With the scrubber and exhaust operating, the test cell ammonia concentration remains below 5 ppm. To further reduce NH3 release into the test cell...material has a high decomposition enthalpy and exhibits decomposition over a wide range of temperatures. AC decomposition produces ammonia and carbon...installation due to toxic gas ( ammonia ) generation during operation. Therefore, the experiment is intended to be remotely operated. A secondary control
Soviet Seismographic Stations and Seismic Instruments. Part 2
1975-06-01
seismograph consisting of a modified Ostrovskiy tiltmeter was tested and Installed at the Obninsk station sometime in the late 1960s. The tiltmeter ...curves of 1 - Ostrovskiy tiltmeter 2 - Press-Ewing seismograph 3 - SMD seismograph [60] signal coil (C1) is now used for calibration and for remote...multichannel teletype seismograph network in Armenia that is suitable for earthquake prediction investigations. It includes up to 70 prognostic sensors and
Time of Flight Estimation in the Presence of Outliers: A Biosonar-Inspired Machine Learning Approach
2013-08-29
REPORT Time of Flight Estimation in the Presence of Outliers: A biosonar -inspired machine learning approach 14. ABSTRACT 16. SECURITY CLASSIFICATION OF...installations, biosonar , remote sensing, sonar resolution, sonar accuracy, sonar energy consumption Nathan Intrator, Leon N Cooper Brown University...Presence of Outliers: A biosonar -inspired machine learning approach Report Title ABSTRACT When the Signal-to-Noise Ratio (SNR) falls below a certain
Energy Trends and Their Implications for U.S. Army Installations
2005-09-01
technolo- gies—primarily flue gas desulfurization (FGD) equipment—that reduce the amounts of sulfur dioxide emitted with coal combustion. As mentioned...natural gas are past their peak and world petroleum production is nearing its peak. Growing domestic consump- tion will continue to increase dependence...on foreign and potentially unstable energy sources. Almost half of the existing U.S. natural gas reserves are considered to be either remote or
The ORSER LANDSAT Data Base of Pennsylvania
NASA Technical Reports Server (NTRS)
Turner, B. J.; Williams, D. L.
1982-01-01
A mosaicked LANDSAT data base for Pennsylvania, installed at the computation center of the Pennsylvania State University is described. Initially constructed by Penn State's Office for Remote Sensing of Earth Resources (ORSER) for the purpose of assisting in state-wide mapping of gypsy moth defoliation, the data base will be available to a variety of potential users. It will provide geometrically correct LANDSAT data accessible by political, jurisdictional, or arbitrary boundaries.
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, workers attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
Remote Sensing Systems Optimization for Geobase Enhancement
2003-03-01
through feedback from base users, as well as the researcher’s observations. 3.1 GeoBase and GIS Learning GeoBase and Geographic Information System ...Abstract The U.S. Air Force is in the process of implementing GeoBase, a geographic information system (GIS), throughout its worldwide installations...Geographic Information System (GIS). A GIS is a computer database that contains geo-spatial information . It is the principal tool used to input, view
AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report
2014-10-09
material. • Hi-Fog and emergency shutdowns – the Pilot House (SCC) has been designated as the main fire control station per ACCU. For this reason, the...decision. In addition, because of the ACCU designation , other required emergency shutdowns will also be located at the SCC. These include remote...3 • Foc’sle Deck Joiner & HVAC – Additional joiner work taking place and several large HVAC duct runs installed
Velásquez-Villada, Carlos; Donoso, Yezid
2016-03-25
Communications from remote areas that may be of interest is still a problem. Many innovative projects applied to remote sites face communications difficulties. The GOLDFISH project was an EU-funded project for river pollution monitoring in developing countries. It had several sensor clusters, with floating WiFi antennas, deployed along a downstream river's course. Sensor clusters sent messages to a Gateway installed on the riverbank. This gateway sent the messages, through a backhaul technology, to an Internet server where data was aggregated over a map. The communication challenge in this scenario was produced by the antennas' movement and network backhaul availability. Since the antennas were floating on the river, communications could be disrupted at any time. Also, 2G/3G availability near the river was not constant. For non-real-time applications, we propose a Delay/Disruption Tolerant Network (DTN)-based solution where all nodes have persistent storage capabilities and DTN protocols to be able to wait minutes or hours to transmit. A mechanical backhaul will periodically visit the river bank where the gateway is installed and it will automatically collect sensor data to be carried to an Internet-covered spot. The proposed forwarding protocol delivers around 98% of the messages for this scenario, performing better than other well-known DTN routing protocols.
Remote Operations of Laser Guide Star Systems: Gemini Observatory.
NASA Astrophysics Data System (ADS)
Oram, Richard J.; Fesquet, Vincent; Wyman, Robert; D'Orgeville, Celine
2011-03-01
The Gemini North telescope, equipped with a 14W laser, has been providing Laser Guide Star Adaptive Optics (LGS AO) regular science queue observations for worldwide astronomers since February 2007. The new 55W laser system for MCAO was installed on the Gemini South telescope in May 2010. In this paper, we comment on how Gemini Observatory developed regular remote operation of the Laser Guide Star Facility and high-power solid-state laser as routine normal operations. Fully remote operation of the LGSF from the Hilo base facility HBF was initially trialed and then optimized and became the standard operating procedure (SOP) for LGS operation in December 2008. From an engineering perspective remote operation demands stable, well characterized and base-lined equipment sets. In the effort to produce consistent, stable and controlled laser parameters (power, wavelength and beam quality) we completed a failure mode effect analysis of the laser system and sub systems that initiated a campaign of hardware upgrades and procedural improvements to the routine maintenance operations. Finally, we provide an overview of normal operation procedures during LGS runs and present a snapshot of data accumulated over several years that describes the overall LGS AO observing efficiency at the Gemini North telescope.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruff, T.M.
1992-01-01
A prototype mucking machine designed to operate in narrow vein stopes was developed by Foster-Miller, Inc., Waltham, MA, under contract with the U.S. Bureau of Mines. The machine, called a compact loader/trammer, or minimucker, was designed to replace slusher muckers in narrow-vein underground mines. The minimucker is a six-wheel-drive, skid-steered, load-haul-dump machine that loads muck at the front with a novel slide-bucket system and ejects it out the rear so that the machine does not have to be turned around. To correct deficiencies of the tether remote control system, a computer-based, radio remote control was retrofitted to the minimucker. Initialmore » tests indicated a need to assist the operator in guiding the machine in narrow stopes and an automatic guidance system that used ultrasonic ranging sensors and a wall-following algorithm was installed. Additional tests in a simulated test stope showed that these changes improved the operation of the minimucker. The design and functions of the minimucker and its computer-based, remote control system are reviewed, and an ultrasonic, sensor-based guidance system is described.« less
Engineering education using a remote laboratory through the Internet
NASA Astrophysics Data System (ADS)
Axaopoulos, Petros J.; Moutsopoulos, Konstantinos N.; Theodoridis, Michael P.
2012-03-01
An experiment using real hardware and under real test conditions can be remotely conducted by engineering students and other interested individuals in the world via the Internet and with the capability of live video streaming from the test site. The presentation of this innovative experiment refers to the determination of the current voltage characteristic curve of a photovoltaic panel installed on the roof of a laboratory, facing south and with the ability to alter its tilt angle, using a closed loop servo motor mounted on the horizontal axis of the panel. The user has the sense of a direct contact with the system since they can intervene and alter the tilt of the panel and get a live visual feedback besides the remote instrumentation panel. The whole procedure takes a few seconds to complete and the characteristic curve is displayed in a chart giving the student and anyone else interested the chance to analyse the results and understand the respective theory; meanwhile, the test data are stored in a file for future use. This type of remote experiment could be used for distance education, training, part-time study and to help students with disabilities to participate in a laboratory environment.
Descriptive Model of Generic WAMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hauer, John F.; DeSteese, John G.
The Department of Energy’s (DOE) Transmission Reliability Program is supporting the research, deployment, and demonstration of various wide area measurement system (WAMS) technologies to enhance the reliability of the Nation’s electrical power grid. Pacific Northwest National Laboratory (PNNL) was tasked by the DOE National SCADA Test Bed Program to conduct a study of WAMS security. This report represents achievement of the milestone to develop a generic WAMS model description that will provide a basis for the security analysis planned in the next phase of this study.
Application of Synchrophasor Measurements for Improving Situational Awareness of the Power System
NASA Astrophysics Data System (ADS)
Obushevs, A.; Mutule, A.
2018-04-01
The paper focuses on the application of synchrophasor measurements that present unprecedented benefits compared to SCADA systems in order to facilitate the successful transformation of the Nordic-Baltic-and-European electric power system to operate with large amounts of renewable energy sources and improve situational awareness of the power system. The article describes new functionalities of visualisation tools to estimate a grid inertia level in real time with monitoring results between Nordic and Baltic power systems.
2015-09-17
network intrusion detection systems NIST National Institute of Standards and Technology p-tree protocol tree PI protocol informatics PLC programmable logic...electrical, water, oil , natural gas, manufacturing, and pharmaceutical industries, to name a few. The differences between SCADA and DCS systems are often... Oil Company, also known as Saudi Aramco, suffered huge data loss that resulted in the disruption of daily operations for nearly two weeks [BTR13]. As it
Kobryn, H T; Lantzke, R; Bell, R; Admiraal, R
2015-03-01
The installation of deep drains is an engineering approach to remediate land salinised by the influence of shallow groundwater. It is a costly treatment and its economic viability is, in part, dependent on the lateral extent to which the drain increases biological productivity by lowering water tables and soil salinity (referred to as the drains' zone of benefit). Such zones may be determined by assessing the biological productivity response of adjacent vegetation over time. We tested a multi-temporal satellite remote sensing method to analyse temporal and spatial changes in vegetation condition surrounding deep drainage sites at five locations in the Western Australian wheatbelt affected by dryland salinity-Morawa, Pithara, Beacon, Narembeen and Dumbleyung. Vegetation condition as a surrogate for biological productivity was assessed by Normalised Difference Vegetation Index (NDVI) during the peak growing season. Analysis was at the site scale within a 1000 m buffer zone from the drains. There was clear evidence of NDVI increasing with elevation, slope and distance from the drain. After accounting for elevation, slope and distance from the drain, there was a significant increase in NDVI across the five locations after installation of deep drains. Changes in NDVI after drainage were broadly consistent with measured changes at each site in groundwater levels after installation of the deep drains. However, this study assessed the lateral extent of benefit for biological productivity and gave a measure of the area of benefit along the entire length of the drain. The method demonstrated the utility of spring NDVI images for rapid and relatively simple assessment of the change in site condition after implementation of drainage, but approaches for further improvement of the procedure were identified. Copyright © 2014 Elsevier Ltd. All rights reserved.
2017-12-08
On Jan. 22, 2015, robotic flight controllers successfully installed NASA’s Cloud Aerosol Transport System (CATS) onboard the International Space Station. CATS will collect data about clouds, volcanic ash plumes and tiny airborne particles that can help improve our understanding of aerosol and cloud interactions, and improve the accuracy of climate change models. CATS had been mounted inside the SpaceX Dragon cargo craft’s unpressurized trunk since it docked at the station on Jan. 12. Ground controllers at NASA’s Johnson Space Center in Houston, Texas, used one of the space station’s robotic arms, called the Special Purpose Dexterous Manipulator, to extract the instrument from the capsule. The NASA-controlled arm passed the instrument to a second robotic arm— like passing a baton in a relay race. This second arm, called the Japanese Experiment Module Remote Manipulator System, is controlled by the Japanese Aerospace Exploration Agency. The Japanese-controlled arm installed the instrument to the Space Station’s Japanese Experiment Module, making CATS the first NASA-developed payload to fly on the Japanese module. CATS is a lidar remote-sensing instrument designed to last from six months to three years. It is specifically intended to demonstrate a low-cost, streamlined approach to developing science payloads on the space station. CATS launched aboard the SpaceX Dragon spacecraft on Jan. 10 at Cape Canaveral Air Force Station in Florida. To learn more about the impact of CATS data, visit: www.nasa.gov/cats/ NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
Modular Seafloor and Water Column Systems for the Ocean Observatories Initiative Cabled Array
NASA Astrophysics Data System (ADS)
Delaney, J. R.; Manalang, D.; Harrington, M.; Tilley, J.; Dosher, J.; Cram, G.; Harkins, G.; McGuire, C.; Waite, P.; McRae, E.; McGinnis, T.; Kenney, M.; Siani, C.; Michel-Hart, N.; Denny, S.; Boget, E.; Kawka, O. E.; Daly, K. L.; Luther, D. S.; Kelley, D. S.; Milcic, M.
2016-02-01
Over the past decade, cabled ocean observatories have become an increasingly important way to collect continuous real-time data at remote subsea locations. This has led to the development of a class of subsea systems designed and built specifically to distribute power and bandwidth among sensing instrumentation on the seafloor and throughout the water column. Such systems are typically powered by shore-based infrastructure and involve networks of fiber optic and electrical cabling that provide real-time data access and control of remotely deployed instrumentation. Several subsea node types were developed and/or adapted for cabled use in order to complete the installation of the largest North American scientific cabled observatory in Oct, 2014. The Ocean Observatories Initiative (OOI) Cabled Array, funded by the US National Science Foundation, consists of a core infrastructure that includes 900 km of fiber optic/electrical cables, seven primary nodes, 18 seafloor junction boxes, three mooring-mounted winched profiling systems, and three wire-crawling profiler systems. In aggregate, the installed infrastructure has 200 dedicated scientific instrument ports (of which 120 are currently assigned), and is capable of further expansion. The installed system has a 25-year design life for reliable, sustained monitoring; and all nodes, profilers and instrument packages are ROV-serviceable. Now in it's second year of operation, the systems that comprise the Cabled Array are providing reliable, 24/7 real-time data collection from deployed instrumentation, and offer a modular and scalable class of subsea systems for ocean observing. This presentation will provide an overview of the observatory-class subsystems of the OOI Cabled Array, focusing on the junction boxes, moorings and profilers that power and communicate with deployed instrumentation.
Research on the inspection robot for cable tunnel
NASA Astrophysics Data System (ADS)
Xin, Shihao
2017-03-01
Robot by mechanical obstacle, double end communication, remote control and monitoring software components. The mechanical obstacle part mainly uses the tracked mobile robot mechanism, in order to facilitate the design and installation of the robot, the other auxiliary swing arm; double side communication part used a combination of communication wire communication with wireless communication, great improve the communication range of the robot. When the robot is controlled by far detection range, using wired communication control, on the other hand, using wireless communication; remote control part mainly completes the inspection robot walking, navigation, positioning and identification of cloud platform control. In order to improve the reliability of its operation, the preliminary selection of IPC as the control core the movable body selection program hierarchical structure as a design basis; monitoring software part is the core part of the robot, which has a definite diagnosis Can be instead of manual simple fault judgment, instead the robot as a remote actuators, staff as long as the remote control can be, do not have to body at the scene. Four parts are independent of each other but are related to each other, the realization of the structure of independence and coherence, easy maintenance and coordination work. Robot with real-time positioning function and remote control function, greatly improves the IT operation. Robot remote monitor, to avoid the direct contact with the staff and line, thereby reducing the accident casualties, for the safety of the inspection work has far-reaching significance.
Dynamic provisioning of local and remote compute resources with OpenStack
NASA Astrophysics Data System (ADS)
Giffels, M.; Hauth, T.; Polgart, F.; Quast, G.
2015-12-01
Modern high-energy physics experiments rely on the extensive usage of computing resources, both for the reconstruction of measured events as well as for Monte-Carlo simulation. The Institut fur Experimentelle Kernphysik (EKP) at KIT is participating in both the CMS and Belle experiments with computing and storage resources. In the upcoming years, these requirements are expected to increase due to growing amount of recorded data and the rise in complexity of the simulated events. It is therefore essential to increase the available computing capabilities by tapping into all resource pools. At the EKP institute, powerful desktop machines are available to users. Due to the multi-core nature of modern CPUs, vast amounts of CPU time are not utilized by common desktop usage patterns. Other important providers of compute capabilities are classical HPC data centers at universities or national research centers. Due to the shared nature of these installations, the standardized software stack required by HEP applications cannot be installed. A viable way to overcome this constraint and offer a standardized software environment in a transparent manner is the usage of virtualization technologies. The OpenStack project has become a widely adopted solution to virtualize hardware and offer additional services like storage and virtual machine management. This contribution will report on the incorporation of the institute's desktop machines into a private OpenStack Cloud. The additional compute resources provisioned via the virtual machines have been used for Monte-Carlo simulation and data analysis. Furthermore, a concept to integrate shared, remote HPC centers into regular HEP job workflows will be presented. In this approach, local and remote resources are merged to form a uniform, virtual compute cluster with a single point-of-entry for the user. Evaluations of the performance and stability of this setup and operational experiences will be discussed.
Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Y. L.; Xie, J. L., E-mail: jlxie@ustc.edu.cn; Yu, C. X.
2016-11-15
Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This “4th generation” MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven bymore » fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy “general optics structure” has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.« less
Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)
NASA Astrophysics Data System (ADS)
Zhu, Y. L.; Xie, J. L.; Yu, C. X.; Zhao, Z. L.; Gao, B. X.; Chen, D. X.; Liu, W. D.; Liao, W.; Qu, C. M.; Luo, C.; Hu, X.; Spear, A. G.; Luhmann, N. C.; Domier, C. W.; Chen, M.; Ren, X.; Tobias, B. J.
2016-11-01
Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This "4th generation" MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven by fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy "general optics structure" has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.
A microcomputer network for control of a continuous mining machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiffbauer, W.H.
1993-12-31
This report details a microcomputer-based control and monitoring network that was developed in-house by the U.S. Bureau of Mines and installed on a continuous mining machine. The network consists of microcomputers that are connected together via a single twisted-pair cable. Each microcomputer was developed to provide a particular function in the control process. Machine-mounted microcomputers, in conjunction with the appropriate sensors, provide closed-loop control of the machine, navigation, and environmental monitoring. Off-the-machine microcomputers provide remote control of the machine, sensor status, and a connection to the network so that external computers can access network data and control the continuous miningmore » machine. Because of the network`s generic structure, it can be installed on most mining machines.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ginn, J.W.
1995-11-01
The photovoltaic systems test facility at Sandia National Laboratories is evaluating the performance of large hybrid power-processing centers (PPC`s). The primary customer for this work has been the Strategic Environmental Research and Development Program (SERDP) of the Department of Defense. One of the goals of SERDP is to develop power-processing hardware to be used in photovoltaic-hybrid power systems at remote military installations. Power for these installations is presently provided by engine-generators. Currently, hardware for twelve such sites is in various stages of procurement. The subject of this talk is testing of the PPC for the first SERDP system, a 300-kWmore » unit for Superior Valley, a US Navy site at China Lake, California.« less
Astronauts Hoffman and Musgrave install the Magnetic Sensing System on HST
1993-12-07
STS061-77-102 (7 Dec 1993) --- Astronauts Jeffrey A. Hoffman (left) and F. Story Musgrave are partially silhouetted against the Indian Ocean as they work to install the Magnetic Sensing System (MSS) on the Hubble Space Telescope (HST). Musgrave is anchored to the end of the Space Shuttle Endeavour's Remote Manipulator System (RMS) arm. The HST is positioned along the southern end of Madagascar, 325 nautical miles away. Visible on the western coast are the sediment laden Onilahy and Fiherenana Rivers which empty into Saint Augustin Bay. North of Fiherenana River is the Mangoky River. The circular feature on the southern end of Madagascar and to the right of HST is the L'ivakoany Mountains. The eastern coast is relatively straight compared to the western coast.
NASA Technical Reports Server (NTRS)
2004-01-01
KENNEDY SPACE CENTER, FLA. A shipping container transporting part of the new Orbiter Boom Sensor System (OBSS) is delivered by truck to the Remote Manipulator System lab in the Vehicle Assembly Building (VAB). Once the entire structure has arrived, the OBSS will be assembled and undergo final checkout and testing in the lab prior to being transferred to the Orbiter Processing Facility (OPF) for installation on Space Shuttle Discovery. The 50-foot-long OBSS will be attached to the Remote Manipulator System, or Shuttle arm, and is one of the new safety measures for Return to Flight, equipping the orbiter with cameras and laser systems to inspect the Shuttle's Thermal Protection System while in space. Discovery is slated to fly mission STS-114 once Space Shuttle launches resume. The launch planning window is May 12 to June 3, 2005.
Alternative power supply systems for remote industrial customers
NASA Astrophysics Data System (ADS)
Kharlamova, N. V.; Khalyasmaa, A. I.; Eroshenko, S. A.
2017-06-01
The paper addresses the problem of alternative power supply of remote industrial clusters with renewable electric energy generation. As a result of different technologies comparison, consideration is given to wind energy application. The authors present a methodology of mean expected wind generation output calculation, based on Weibull distribution, which provides an effective express-tool for preliminary assessment of required installed generation capacity. The case study is based on real data including database of meteorological information, relief characteristics, power system topology etc. Wind generation feasibility estimation for a specific territory is followed by power flow calculations using Monte Carlo methodology. Finally, the paper provides a set of recommendations to ensure safe and reliable power supply for the final customers and, subsequently, to provide sustainable development of the regions, located far from megalopolises and industrial centres.
NASA Technical Reports Server (NTRS)
Woodfill, J. R.; Thomson, F. J.
1979-01-01
The paper deals with the design, construction, and applications of an active/passive multispectral scanner combining lasers with conventional passive remote sensors. An application investigation was first undertaken to identify remote sensing applications where active/passive scanners (APS) would provide improvement over current means. Calibration techniques and instrument sensitivity are evaluated to provide predictions of the APS's capability to meet user needs. A preliminary instrument design was developed from the initial conceptual scheme. A design review settled the issues of worthwhile applications, calibration approach, hardware design, and laser complement. Next, a detailed mechanical design was drafted and construction of the APS commenced. The completed APS was tested and calibrated in the laboratory, then installed in a C-47 aircraft and ground tested. Several flight tests completed the test program.
Water survey of Canada: Application for use of ERTS-A for retransmission of water resources data
NASA Technical Reports Server (NTRS)
Halliday, R. A. (Principal Investigator); Reid, I. A.
1974-01-01
The author has identified the following significant results. Water resources data were retransmitted from nine data collection platforms (DCP) located in remote regions of Canada. The DCPs located in the Arctic operated in temperatures lower than -40 C and the DCP antennas have survived wind speeds of greater than 80 kph and snow loads of a depth of one metre. Ice-out indicators were installed at a few DCP sites. The purpose of these indicators was to enable the detection of the movement of ice out of river channel during spring break-up. The suitability of satellite retransmission as a means of obtaining data from remote areas of Canada continues to be demonstrated. A modest expansion of the DCP network is planned.
Satellite services system analysis study. Volume 4: Service equipment concepts
NASA Technical Reports Server (NTRS)
1981-01-01
Payload deployment equipment is discussed, including payload separation, retention structures, the remote manipulator system, tilt tables, the payload installation and deployment aid, the handling and positioning aid, and spin tables. Close proximity retrieval, and on-orbit servicing equipment is discussed. Backup and contingency equipment is also discussed. Delivery and retrieval of high-energy payloads are considered. Earth return equipment, the aft flight deck, optional, and advanced equipment are also discussed.
Salivary immunoassays to investigate potential exposure to ...
This presentation provides an update to an ongoing collaboration with Inter American University of Puerto Rico. The goal of this study is to investigate public health benefits that result from implementation of low cost, sustainable filtration technologies in remote, rural communities in Puerto Rico. To present an update to an ongoing collaborative project with Inter American University of Puerto Rico which investigates the health benefits that may result from installation of community level water filtration systems.
Windows NT Attacks for the Evaluation of Intrusion Detection Systems
2000-06-01
their passwords never expire. Their privileges allow telnet access and FTP access to the system, but do not allow local logins . Each user can...default: • Administrator: This root account allows remote and local logins and full control of system software. • Guest: This default account, setup by...realizing that the Netbus server was installed. The attack also edits the Windows NT Registry so the Netbus server restarts at every login . This
A Prospective Evaluation of ENT Telemedicine in Remote Military Populations Seeking Specialty Care
2002-01-01
wee con - MTFs ashore provides an opportunity to study ducted by an ENT specialty physician. The data telemedicine use by military medical personnel...medical officers ( GMOs ), IDCs, and telemedicine network completed telephone in- TELEMEDICINE AND MILITARY SPECIALTY CARE 303 terviews. These were...consisted of 2 GMOs , 3 primary and recorded via a secure Web-based applica- care physicians, and 3 specialty physicians tion installed for Region 9. When a
1979-04-01
two generators. A 7-5-kW vacu-flow air- cooled generator was installed in the trailer to power the instrumentation. The heating , air...off power. 2. A test facility which would allow the emission tests to be conducted at designated airport run-up locations. Since emission...near the airport runways. The remote location led to instrumentation. -*—*-*——- ■- ---’-• ■ - - - together with bottled gases
2007-02-19
KENNEDY SPACE CENTER, FLA. -- Inside the Space Station Processing Facility at Kennedy Space Center, a worker helps to attach the Remote Manipulator System, or robotic arm, to the Japanese Experiment Module for testing. The RMS is one of the payloads scheduled to be delivered to the station on a future mission tentatively scheduled for 2008. The RMS is similar to the robotic arm already installed on the station's mobile base system. Photo credit: NASA/Amanda Diller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, J M; Ehinger, M H; Joseph, C
1978-10-01
Development work on a computerized system for nuclear materials control and accounting in a nuclear fuel reprocessing plant is described and evaluated. Hardware and software were installed and tested to demonstrate key measurement, measurement control, and accounting requirements at accountability input/output points using natural uranium. The demonstration included a remote data acquisition system which interfaces process and special instrumentation to a cenral processing unit.
Implementation of Remote Corrosion-Monitoring Sensor for Mission-Essential Structures at Okinawa
2009-08-01
with voluminous corrosion products. Martensitic stainless steels are susceptible to pitting and chlo- ride stress corrosion cracking in marine... steel , zinc- rich epoxy-coated steel , phenolic coated steel and bare type 410 stainless steel . (The steel panels were A36 steel .) The racks were...and ER probes were installed on building number 125. The coupons were mounted to an aluminum frame using stainless steel bolts and nylon spacer
NASA Astrophysics Data System (ADS)
Kochukov, O.; Briņķis, K.; Mutule, A.
2013-08-01
The paper describes the algorithm for distributed state estimation (SE) and is focused on its testing and validation. For this purpose, different events in the modeled power system of the 330-750 kV electrical ring Latvia - Lithuania - Belarus - Smolensk - Moscow - St. Petersburg - Estonia - Latvia were considered. The methods for testing the Inter-TSO SE prototype and dynamic network monitoring & modeling are based on comparison of the available SCADA data about real events with those of SE calculation. In total, four operational states were studied, including initial, accident and two post-accident operational states Rakstā tiek aprakstīti, testēti un novērtēti izkliedēta stāvokļa novērtēšanas algoritmi. Testēšanas nolūkos tika izmantoti dažādi 330-750 kV elektriskā loka Latvija - Lietuva - Baltkrievija - Smoļenska - Maskava - Pēterburga - Igaunija - Latvija modelēti scenāriji. Prototipa testēšanas metodoloģija balstīta uz pieejamo SCADA datu salīdzināšanu ar stāvokļa novērtēšanas prototipa aprēķina rezultātiem. Kopumā apskatīti sākotnējais, avārijas un divi pēcavārijas režīmi
STS-113 Astronauts Work on Port One (P1) Truss on International Space Station
NASA Technical Reports Server (NTRS)
2002-01-01
The 16th American assembly flight and 112th overall American flight to the International Space Station (ISS) launched on November 23, 2002 from Kennedy's launch pad 39A aboard the Space Shuttle Orbiter Endeavor STS-113. Mission objectives included the delivery of the Expedition Six Crew to the ISS, the return of Expedition Five crew back to Earth, and the installation and activation of the Port 1 Integrated Truss Assembly (P1). The first major component installed on the left side of the Station, the P1 truss provides an additional three External Thermal Control System radiators. Weighing in at 27,506 pounds, the P1 truss is 45 feet (13.7 meters) long, 15 feet (4.6 meters) wide, and 13 feet (4 meters) high. Three space walks, aided by the use of the Robotic Manipulator Systems of both the Shuttle and the Station, were performed in the installation of P1. In this photograph, astronauts Michael E. Lopez-Alegria (above) and John B. Herrington (below) work on the newly installed P1 truss during the mission's second scheduled session of extravehicular activity. The space walk lasted 6 hours, 10 minutes. The end effector of the Canadarm2 or Space Station Remote Manipulator System (SSRMS) and Earth's horizon are visible in the bottom of frame.
Investigating Near Space Interaction Regions: Developing a Remote Observatory
NASA Astrophysics Data System (ADS)
Gallant, M.; Mierkiewicz, E. J.; Oliversen, R. J.; Jaehnig, K.; Percival, J.; Harlander, J.; Englert, C. R.; Kallio, R.; Roesler, F. L.; Nossal, S. M.; Gardner, D.; Rosborough, S.
2016-12-01
The Investigating Near Space Interaction Regions (INSpIRe) effort will (1) establish an adaptable research station capable of contributing to terrestrial and planetary aeronomy; (2) integrate two state-of-the-art second generation Fabry-Perot (FP) and Spatial Heteorodyne Spectrometers (SHS) into a remotely operable configuration; (3) deploy this instrumentation to a clear-air site, establishing a stable, well-calibrated observatory; (4) embark on a series of observations designed to contribute to three major areas of geocoronal research: geocoronal physics, structure/coupling, and variability. This poster describes the development of the INSpIRe remote observatory. Based at Embry-Riddle Aeronautical University (ERAU), initiative INSpIRe provides a platform to encourage the next generation of researchers to apply knowledge gained in the classroom to real-world science and engineering. Students at ERAU contribute to the INSpIRe effort's hardware and software needs. Mechanical/optical systems are in design to bring light to any of four instruments. Control software is in development to allow remote users to control everything from dome and optical system operations to calibration and data collection. In April 2016, we also installed and tested our first science instrument in the INSpIRe trailer, the Redline DASH Demonstration Instrument (REDDI). REDDI uses Doppler Asymmetric Spatial Heterodyne (DASH) spectroscopy, and its deployment as part of INSpIRe is a collaborative research effort between the Naval Research Lab, St Cloud State University, and ERAU. Similar to a stepped Michelson device, REDDI measures oxygen (630.0 nm) winds from the thermosphere. REDDI is currently mounted in a temporary location under INSpIRe's main siderostat until its entrance optical system can be modified. First light tests produced good signal-to-noise fringes in ten minute integrations, indicating that we will soon be able to measure thermospheric winds from our Daytona Beach testing site. Future work will involve installation and software integration of FP and SHS systems and the Embry-Riddle Instrument Control System. The INSpIRe project is funded through NSF-CAREER award AGS135231 and the NASA Planetary Solar System Observations Program. The REDDI instrument was supported by the Chief of Naval Research.
DOE/NREL supported wind energy activities in Alaska
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drouilhet, S.
1997-12-01
This paper describes three wind energy projects implemented in Alaska. The first, a sustainable technology energy partnerships (STEP) wind energy deployment project in Kotzebue will install 6 AOC 15/50 wind turbines and connect to the existing village diesel grid, consisting of approximately 1 MW average load. It seeks to develop solutions to the problems of arctic wind energy installations (transport, foundations, erection, operation, and maintenance), to establish a wind turbine test site, and to establish the Kotzebue Electric Association as a training and deployment center for wind/diesel technology in rural Alaska. The second project, a large village medium-penetration wind/diesel system,more » also in Kotzebue, will install a 1-2 MW windfarm, which will supplement the AOC turbines of the STEP project. The program will investigate the impact of medium penetration wind energy on power quality and system stability. The third project, the Alaska high-penetration wind/diesel village power pilot project in Wales will install a high penetration (80-100%) wind/diesel system in a remote Alaskan village. The system will include about 180 kW installed wind capacity, meeting an average village load of about 60 kW. This program will provide a model for high penetration wind retrofits to village diesel power systems and build the capability in Alaska to operate, maintain, and replicate wind/diesel technology. The program will also address problems of: effective use of excess wind energy; reliable diesel-off operation; and the role of energy storage.« less
Remote Sensing Monitoring of Changes in Soil Salinity: A Case Study in Inner Mongolia, China.
Wu, Jingwei; Vincent, Bernard; Yang, Jinzhong; Bouarfa, Sami; Vidal, Alain
2008-11-07
This study used archived remote sensing images to depict the history of changes in soil salinity in the Hetao Irrigation District in Inner Mongolia, China, with the purpose of linking these changes with land and water management practices and to draw lessons for salinity control. Most data came from LANDSAT satellite images taken in 1973, 1977, 1988, 1991, 1996, 2001, and 2006. In these years salt-affected areas were detected using a normal supervised classification method. Corresponding cropped areas were detected from NVDI (Normalized Difference Vegetation Index) values using an unsupervised method. Field samples and agricultural statistics were used to estimate the accuracy of the classification. Historical data concerning irrigation/drainage and the groundwater table were used to analyze the relation between changes in soil salinity and land and water management practices. Results showed that: (1) the overall accuracy of remote sensing in detecting soil salinity was 90.2%, and in detecting cropped area, 98%; (2) the installation/innovation of the drainage system did help to control salinity; and (3) a low ratio of cropped land helped control salinity in the Hetao Irrigation District. These findings suggest that remote sensing is a useful tool to detect soil salinity and has potential in evaluating and improving land and water management practices.
Photovoltaic Power System and Power Distribution Demonstration for the Desert RATS Program
NASA Technical Reports Server (NTRS)
Colozza, Anthony; Jakupca, Ian; Mintz, Toby; Herlacher, Mike; Hussey, Sam
2012-01-01
A stand alone, mobile photovoltaic power system along with a cable deployment system was designed and constructed to take part in the Desert Research And Technology Studies (RATS) lunar surface human interaction evaluation program at Cinder Lake, Arizona. The power system consisted of a photovoltaic array/battery system. It is capable of providing 1 kW of electrical power. The system outputs were 48 V DC, 110 V AC, and 220 V AC. A cable reel with 200 m of power cable was used to provide power from the trailer to a remote location. The cable reel was installed on a small trailer. The reel was powered to provide low to no tension deployment of the cable. The cable was connected to the 220 V AC output of the power system trailer. The power was then converted back to 110 V AC on the cable deployment trailer for use at the remote site. The Scout lunar rover demonstration vehicle was used to tow the cable trailer and deploy the power cable. This deployment was performed under a number of operational scenarios, manned operation, remote operation and tele-robotically. Once deployed, the cable was used to provide power, from the power system trailer, to run various operational tasks at the remote location.