Sample records for remove high frequency

  1. High-frequency filtering of strong-motion records

    USGS Publications Warehouse

    Douglas, J.; Boore, D.M.

    2011-01-01

    The influence of noise in strong-motion records is most problematic at low and high frequencies where the signal to noise ratio is commonly low compared to that in the mid-spectrum. The impact of low-frequency noise (5 Hz) on computed pseudo-absolute response spectral accelerations (PSAs). In contrast to the case of low-frequency noise our analysis shows that filtering to remove high-frequency noise is only necessary in certain situations and that PSAs can often be used up to 100 Hz even if much lower high-cut corner frequencies are required to remove the noise. This apparent contradiction can be explained by the fact that PSAs are often controlled by ground accelerations associated with much lower frequencies than the natural frequency of the oscillator because path and site attenuation (often modelled by Q and κ, respectively) have removed the highest frequencies. We demonstrate that if high-cut filters are to be used, then their corner frequencies should be selected on an individual basis, as has been done in a few recent studies.

  2. The arsenic removal from arsenopyrite in sulfide mineral by physicochemical extraction

    NASA Astrophysics Data System (ADS)

    Jo, Jiyu; Cho, Kanghee; Choi, Nagchoul; Park*, Cheonyoung

    2015-04-01

    The most abundant As ore mineral is arsenopyrite (FeAsS). Arsenopyrite is present in sulfide ores associated with sediment-hosted Au deposits, it tends to be the earliest-formed mineral, derived from hydrothermal solutions and formed at temperatures typically of 100(degree Celsius) or more. The aim of this study was to investigate the mineralogical phase change and arsenic removal from arsenopyrite as a penalty element in sulfide mineral contained Au by physical extraction (high frequency) and chemical leaching (thiocyanate). Arsenic removal experiments for were performed under various conditions of high frequency exposure(1~35 min), thiocyanate concentration (0.1~1.0M), HCl concentration (0.1~2.0M), copper(2) sulfate concentration (0.1~1.0M), temperature (30~60 degree Celsius). Increasing the high frequency exposure produced a positive effect on arsenic removal in arsenopyrite. The highest percentage arsenic removal of 96.67% was obtained under the following conditions by thiocyanate leaching: thiocyanate concentration = 1.0M ; HCl concentration = 2.0M ; copper(2) sulfate concentration = 1.0M ; temperature = 60(degree Celsius) This study demonstrates the adequate performance of physical extraction (high frequency) and chemical leaching (thiocyanate) for the arsenic removal from arsenopyrite as a penalty element.

  3. Gender identification from high-pass filtered vowel segments: the use of high-frequency energy.

    PubMed

    Donai, Jeremy J; Lass, Norman J

    2015-10-01

    The purpose of this study was to examine the use of high-frequency information for making gender identity judgments from high-pass filtered vowel segments produced by adult speakers. Specifically, the effect of removing lower-frequency spectral detail (i.e., F3 and below) from vowel segments via high-pass filtering was evaluated. Thirty listeners (ages 18-35) with normal hearing participated in the experiment. A within-subjects design was used to measure gender identification for six 250-ms vowel segments (/æ/, /ɪ /, /ɝ/, /ʌ/, /ɔ/, and /u/), produced by ten male and ten female speakers. The results of this experiment demonstrated that despite the removal of low-frequency spectral detail, the listeners were accurate in identifying speaker gender from the vowel segments, and did so with performance significantly above chance. The removal of low-frequency spectral detail reduced gender identification by approximately 16 % relative to unfiltered vowel segments. Classification results using linear discriminant function analyses followed the perceptual data, using spectral and temporal representations derived from the high-pass filtered segments. Cumulatively, these findings indicate that normal-hearing listeners are able to make accurate perceptual judgments regarding speaker gender from vowel segments with low-frequency spectral detail removed via high-pass filtering. Therefore, it is reasonable to suggest the presence of perceptual cues related to gender identity in the high-frequency region of naturally produced vowel signals. Implications of these findings and possible mechanisms for performing the gender identification task from high-pass filtered stimuli are discussed.

  4. Automatic seizure detection in SEEG using high frequency activities in wavelet domain.

    PubMed

    Ayoubian, L; Lacoma, H; Gotman, J

    2013-03-01

    Existing automatic detection techniques show high sensitivity and moderate specificity, and detect seizures a relatively long time after onset. High frequency (80-500 Hz) activity has recently been shown to be prominent in the intracranial EEG of epileptic patients but has not been used in seizure detection. The purpose of this study is to investigate if these frequencies can contribute to seizure detection. The system was designed using 30 h of intracranial EEG, including 15 seizures in 15 patients. Wavelet decomposition, feature extraction, adaptive thresholding and artifact removal were employed in training data. An EMG removal algorithm was developed based on two features: Lack of correlation between frequency bands and energy-spread in frequency. Results based on the analysis of testing data (36 h of intracranial EEG, including 18 seizures) show a sensitivity of 72%, a false detection of 0.7/h and a median delay of 5.7 s. Missed seizures originated mainly from seizures with subtle or absent high frequencies or from EMG removal procedures. False detections were mainly due to weak EMG or interictal high frequency activities. The system performed sufficiently well to be considered for clinical use, despite the exclusive use of frequencies not usually considered in clinical interpretation. High frequencies have the potential to contribute significantly to the detection of epileptic seizures. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  5. Automatic seizure detection in SEEG using high frequency activities in wavelet domain

    PubMed Central

    Ayoubian, L.; Lacoma, H.; Gotman, J.

    2015-01-01

    Existing automatic detection techniques show high sensitivity and moderate specificity, and detect seizures a relatively long time after onset. High frequency (80–500 Hz) activity has recently been shown to be prominent in the intracranial EEG of epileptic patients but has not been used in seizure detection. The purpose of this study is to investigate if these frequencies can contribute to seizure detection. The system was designed using 30 h of intracranial EEG, including 15 seizures in 15 patients. Wavelet decomposition, feature extraction, adaptive thresholding and artifact removal were employed in training data. An EMG removal algorithm was developed based on two features: Lack of correlation between frequency bands and energy-spread in frequency. Results based on the analysis of testing data (36 h of intracranial EEG, including 18 seizures) show a sensitivity of 72%, a false detection of 0.7/h and a median delay of 5.7 s. Missed seizures originated mainly from seizures with subtle or absent high frequencies or from EMG removal procedures. False detections were mainly due to weak EMG or interictal high frequency activities. The system performed sufficiently well to be considered for clinical use, despite the exclusive use of frequencies not usually considered in clinical interpretation. High frequencies have the potential to contribute significantly to the detection of epileptic seizures. PMID:22647836

  6. Techniques for noise removal and registration of TIMS data

    USGS Publications Warehouse

    Hummer-Miller, S.

    1990-01-01

    Extracting subtle differences from highly correlated thermal infrared aircraft data is possible with appropriate noise filters, constructed and applied in the spatial frequency domain. This paper discusses a heuristic approach to designing noise filters for removing high- and low-spatial frequency striping and banding. Techniques for registering thermal infrared aircraft data to a topographic base using Thematic Mapper data are presented. The noise removal and registration techniques are applied to TIMS thermal infrared aircraft data. -Author

  7. The effect of sampling rate and anti-aliasing filters on high-frequency response spectra

    USGS Publications Warehouse

    Boore, David M.; Goulet, Christine

    2013-01-01

    The most commonly used intensity measure in ground-motion prediction equations is the pseudo-absolute response spectral acceleration (PSA), for response periods from 0.01 to 10 s (or frequencies from 0.1 to 100 Hz). PSAs are often derived from recorded ground motions, and these motions are usually filtered to remove high and low frequencies before the PSAs are computed. In this article we are only concerned with the removal of high frequencies. In modern digital recordings, this filtering corresponds at least to an anti-aliasing filter applied before conversion to digital values. Additional high-cut filtering is sometimes applied both to digital and to analog records to reduce high-frequency noise. Potential errors on the short-period (high-frequency) response spectral values are expected if the true ground motion has significant energy at frequencies above that of the anti-aliasing filter. This is especially important for areas where the instrumental sample rate and the associated anti-aliasing filter corner frequency (above which significant energy in the time series is removed) are low relative to the frequencies contained in the true ground motions. A ground-motion simulation study was conducted to investigate these effects and to develop guidance for defining the usable bandwidth for high-frequency PSA. The primary conclusion is that if the ratio of the maximum Fourier acceleration spectrum (FAS) to the FAS at a frequency fsaa corresponding to the start of the anti-aliasing filter is more than about 10, then PSA for frequencies above fsaa should be little affected by the recording process, because the ground-motion frequencies that control the response spectra will be less than fsaa . A second topic of this article concerns the resampling of the digital acceleration time series to a higher sample rate often used in the computation of short-period PSA. We confirm previous findings that sinc-function interpolation is preferred to the standard practice of using linear time interpolation for the resamplin

  8. The Fe removal in pyrophyllite by physical method

    NASA Astrophysics Data System (ADS)

    Cho, Kanghee; Jo, Jiyu; Bak, GeonYeong; Choi, NagChoul; Park*, CheonYoung

    2015-04-01

    The presence of Fe in ingredient material such as limestone, borax and pyrophyllite can prevent their use mainly in the glass fiber manufacturing industry. The red to yellow pigmentation in pyrophyllite is mainly due to the associated oxides and sulfides of Fe such as hematite, pyrite, etc. The removal of Fe in the pyrophyllite was investigated using high frequency treatment and magnetic separation under various alumina grades in pyrophyllite. The hematite and pyrite were observed in the pyrophyllite from photomicrograph and XRD analysis results. On the decrease of Al2O3 content in pyrophyllite was showed that SiO2, Fe2O3 and TiO2 content were increased by XRF analysis. The high frequency treatment experiment for the pyrophyllite showed that the (1) pyrite phase was transformed hematite and magnetite, (2) mass loss of the sample by volatilization of included sulfur(S) in pyrite. The results of magnetic separation for treated sample by high frequency were identified that Fe removal percent were in the range of 97.6~98.8%. This study demonstrated that physical method (high frequency treatment and magnetic separation) was effective for the removal of Fe in pyrophyllite. This subject is supported by Korea Ministry of Environment(MOE) as "Advanced Technology Program for Environmental Industry".

  9. Computer Controlled Optical Surfacing With Orbital Tool Motion

    NASA Astrophysics Data System (ADS)

    Jones, Robert A.

    1985-10-01

    Asymmetric aspheric optical surfaces are very difficult to fabricate using classical techniques and laps the same size as the workpiece. Opticians can produce such surfaces by grinding and polishing, using small laps with orbital tool motion. However, hand correction is a time consuming process unsuitable for large optical elements. Itek has developed Computer Controlled Optical Surfacing (CCOS) for fabricating such aspheric optics. Automated equipment moves a nonrotating orbiting tool slowly over the workpiece surface. The process corrects low frequency surface errors by figuring. The velocity of the tool assembly over the workpiece surface is purposely varied. Since the amount of material removal is proportional to the polishing or grinding time, accurate control over material removal is achieved. The removal of middle and high frequency surface errors is accomplished by pad smoothing. For a soft pad material, the pad will compress to fit the workpiece surface producing greater pressure and more removal at the surface high areas. A harder pad will ride on only the high regions resulting in removal only for those locations.

  10. Acoustic agglomeration of fine particles based on a high intensity acoustical resonator

    NASA Astrophysics Data System (ADS)

    Zhao, Yun; Zeng, Xinwu; Tian, Zhangfu

    2015-10-01

    Acoustic agglomeration (AA) is considered to be a promising method for reducing the air pollution caused by fine aerosol particles. Removal efficiency and energy consuming are primary parameters and generally have a conflict with each other for the industry applications. It was proved that removal efficiency is increased with sound intensity and optimal frequency is presented for certain polydisperse aerosol. As a result, a high efficiency and low energy cost removal system was constructed using acoustical resonance. High intensity standing wave is generated by a tube system with abrupt section driven by four loudspeakers. Numerical model of the tube system was built base on the finite element method, and the resonance condition and SPL increase were confirmd. Extensive tests were carried out to investigate the acoustic field in the agglomeration chamber. Removal efficiency of fine particles was tested by the comparison of filter paper mass and particle size distribution at different operating conditions including sound pressure level (SPL), and frequency. The experimental study has demonstrated that agglomeration increases with sound pressure level. Sound pressure level in the agglomeration chamber is between 145 dB and 165 dB from 500 Hz to 2 kHz. The resonance frequency can be predicted with the quarter tube theory. Sound pressure level gain of more than 10 dB is gained at resonance frequency. With the help of high intensity sound waves, fine particles are reduced greatly, and the AA effect is enhanced at high SPL condition. The optimal frequency is 1.1kHz for aerosol generated by coal ash. In the resonace tube, higher resonance frequencies are not the integral multiplies of the first one. As a result, Strong nonlinearity is avoided by the dissonant characteristic and shock wave is not found in the testing results. The mechanism and testing system can be used effectively in industrial processes in the future.

  11. Combined fabrication technique for high-precision aspheric optical windows

    NASA Astrophysics Data System (ADS)

    Hu, Hao; Song, Ci; Xie, Xuhui

    2016-07-01

    Specifications made on optical components are becoming more and more stringent with the performance improvement of modern optical systems. These strict requirements not only involve low spatial frequency surface accuracy, mid-and-high spatial frequency surface errors, but also surface smoothness and so on. This presentation mainly focuses on the fabrication process for square aspheric window which combines accurate grinding, magnetorheological finishing (MRF) and smoothing polishing (SP). In order to remove the low spatial frequency surface errors and subsurface defects after accurate grinding, the deterministic polishing method MRF with high convergence and stable material removal rate is applied. Then the SP technology with pseudo-random path is adopted to eliminate the mid-and-high spatial frequency surface ripples and high slope errors which is the defect for MRF. Additionally, the coordinate measurement method and interferometry are combined in different phase. Acid-etched method and ion beam figuring (IBF) are also investigated on observing and reducing the subsurface defects. Actual fabrication result indicates that the combined fabrication technique can lead to high machining efficiency on manufaturing the high-precision and high-quality optical aspheric windows.

  12. Past agricultural land use and present-day fire regimes can interact to determine the nature of seed predation.

    PubMed

    Stuhler, John D; Orrock, John L

    2016-06-01

    Historical agriculture and present-day fire regimes can have significant effects on contemporary ecosystems. Although past agricultural land use can lead to long-term changes in plant communities, it remains unclear whether these persistent land-use legacies alter plant-consumer interactions, such as seed predation, and whether contemporary disturbance (e.g., fire) alters the effects of historical agriculture on these interactions. We conducted a study at 27 sites distributed across 80,300 ha in post-agricultural and non-agricultural longleaf pine woodlands with different degrees of fire frequency to test the hypothesis that past and present-day disturbances that alter plant communities can subsequently alter seed predation. We quantified seed removal by arthropods and rodents for Tephrosia virginiana and Vernonia angustifolia, species of conservation interest. We found that the effects of land-use history and fire frequency on seed removal were contingent on granivore guild and microhabitat characteristics. Tephrosia virginiana removal was greater in low fire frequency sites, due to greater seed removal by rodents. Although overall removal of V. angustifolia did not differ among habitats, rodents removed more seeds than arthropods at post-agricultural sites and non-agricultural sites with low fire frequencies, but not at non-agricultural sites with high fire frequencies. Land-use history and fire frequency also affected the relationship between microhabitat characteristics and removal of V. angustifolia. Our results suggest that historical agriculture and present-day fire regimes may alter seed predation by shifting the impact of rodent and arthropod seed predators among habitats, with potential consequences for the establishment of rare plant species consumed by one or both predators.

  13. Medium-high frequency ultrasound and ozone based advanced oxidation for amoxicillin removal in water.

    PubMed

    Kıdak, Rana; Doğan, Şifa

    2018-01-01

    In this study, treatment of an antibiotic compound amoxicillin by medium-high frequency ultrasonic irradiation and/or ozonation has been studied. Ultrasonic irradiation process was carried out in a batch reactor for aqueous amoxicillin solutions at three different frequencies (575, 861 and 1141kHz). The applied ultrasonic power was 75W and the diffused power was calculated as 14.6W/L. The highest removal was achieved at 575kHz ultrasonic frequency (>99%) with the highest pseudo first order reaction rate constant 0.04min -1 at pH 10 but the mineralization achieved was around 10%. Presence of alkalinity and humic acid species had negative effect on the removal efficiency (50% decrease). To improve the poor outcomes, ozonation had been applied with or without ultrasound. Ozone removed the amoxicillin at a rate 50 times faster than ultrasound. Moreover, due to the synergistic effect, coupling of ozone and ultrasound gave rise to rate constant of 2.5min -1 (625 times higher than ultrasound). In the processes where ozone was used, humic acid did not show any significant effect because the rate constant was so high that ozone has easily overcome the scavenging effects of natural water constituents. Furthermore, the intermediate compounds, after the incomplete oxidation mechanisms, has been analyzed to reveal the possible degradation pathways of amoxicillin through ultrasonic irradiation and ozonation applications. The outcomes of the intermediate compounds experiments and the toxicity was investigated to give a clear explanation about the safety of the resulting solution. The relevance of all the results concluded that hybrid advanced oxidation system was the best option for amoxicillin removal. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Spectrum study on unsteadiness of shock wave-vortex ring interaction

    NASA Astrophysics Data System (ADS)

    Dong, Xiangrui; Yan, Yonghua; Yang, Yong; Dong, Gang; Liu, Chaoqun

    2018-05-01

    Shock oscillation with low-frequency unsteadiness commonly occurs in supersonic flows and is a top priority for the control of flow separation caused by shock wave and boundary layer interaction. In this paper, the interaction of the shock caused by the compression ramp and the vortex rings generated by a micro-vortex generator (MVG) in a supersonic flow at Ma = 2.5 is simulated by the implicit large eddy simulation method. The analysis of observation and the frequency of both the vortex ring motion and the shock oscillation is carried out. The results show that the shock produced by a compression ramp flow at Ma = 2.5 has a dominant non-dimensional low frequency, which is around St = 0.002, while the vortex rings behind the MVG have a dominant high frequency which is around St = 0.038. The dominant low frequency of the shock, which is harmful, can be removed or weakened through the shock-vortex ring interaction by the vortex rings which generate high frequency fluctuations. In the shock and vortex ring interaction region, a dominant high frequency St = 0.037-0.038 has been detected rather than the low frequency St = 0.002, which indicates that the vortex ring is stiff enough to break or weaken the shock. This analysis could provide an effective tool to remove or weaken the low frequency pressure fluctuation below 500 Hz, which has a negative effect on the flight vehicle structures and the environmental protection, through the high frequency vortex generation.

  15. Megasonic cleaning strategy for sub-10nm photomasks

    NASA Astrophysics Data System (ADS)

    Hsu, Jyh-Wei; Samayoa, Martin; Dress, Peter; Dietze, Uwe; Ma, Ai-Jay; Lin, Chia-Shih; Lai, Rick; Chang, Peter; Tuo, Laurent

    2016-10-01

    One of the main challenges in photomask cleaning is balancing particle removal efficiency (PRE) with pattern damage control. To overcome this challenge, a high frequency megasonic cleaning strategy is implemented. Apart from megasonic frequency and power, photomask surface conditioning also influences cleaning performance. With improved wettability, cleanliness is enhanced while pattern damage risk is simultaneously reduced. Therefore, a particle removal process based on higher megasonic frequencies, combined with proper surface pre-treatment, provides improved cleanliness without the unintended side effects of pattern damage, thus supporting the extension of megasonic cleaning technology into 10nm half pitch (hp) device node and beyond.

  16. Acoustic Methods Remove Bubbles From Liquids

    NASA Technical Reports Server (NTRS)

    Trinh, E.; Elleman, D. D.; Wang, T. G.

    1983-01-01

    Two acoustic methods applied to molten glass or other viscous liquids to remove bubbles. Bubbles are either absorbed or brought to surface by applying high-intensity Sonic field at resonant frequency. Sonic oscillation increases surface area of bubbles and causes them to dissipate.

  17. Mechanisms of Left-Right Coordination in Mammalian Locomotor Pattern Generation Circuits: A Mathematical Modeling View

    PubMed Central

    Talpalar, Adolfo E.; Rybak, Ilya A.

    2015-01-01

    The locomotor gait in limbed animals is defined by the left-right leg coordination and locomotor speed. Coordination between left and right neural activities in the spinal cord controlling left and right legs is provided by commissural interneurons (CINs). Several CIN types have been genetically identified, including the excitatory V3 and excitatory and inhibitory V0 types. Recent studies demonstrated that genetic elimination of all V0 CINs caused switching from a normal left-right alternating activity to a left-right synchronized “hopping” pattern. Furthermore, ablation of only the inhibitory V0 CINs (V0D subtype) resulted in a lack of left-right alternation at low locomotor frequencies and retaining this alternation at high frequencies, whereas selective ablation of the excitatory V0 neurons (V0V subtype) maintained the left–right alternation at low frequencies and switched to a hopping pattern at high frequencies. To analyze these findings, we developed a simplified mathematical model of neural circuits consisting of four pacemaker neurons representing left and right, flexor and extensor rhythm-generating centers interacting via commissural pathways representing V3, V0D, and V0V CINs. The locomotor frequency was controlled by a parameter defining the excitation of neurons and commissural pathways mimicking the effects of N-methyl-D-aspartate on locomotor frequency in isolated rodent spinal cord preparations. The model demonstrated a typical left-right alternating pattern under control conditions, switching to a hopping activity at any frequency after removing both V0 connections, a synchronized pattern at low frequencies with alternation at high frequencies after removing only V0D connections, and an alternating pattern at low frequencies with hopping at high frequencies after removing only V0V connections. We used bifurcation theory and fast-slow decomposition methods to analyze network behavior in the above regimes and transitions between them. The model reproduced, and suggested explanation for, a series of experimental phenomena and generated predictions available for experimental testing. PMID:25970489

  18. Water reduction by constructed wetlands treating waste landfill leachate in a tropical region.

    PubMed

    Ogata, Yuka; Ishigaki, Tomonori; Ebie, Yoshitaka; Sutthasil, Noppharit; Chiemchaisri, Chart; Yamada, Masato

    2015-10-01

    One of the key challenges in landfill leachate management is the prevention of environmental pollution by the overflow of untreated leachate. To evaluate the feasibility of constructed wetlands (CWs) for the treatment of waste landfill leachate in tropical regions, water reduction and pollutant removal by a CW subjected to different flow patterns (i.e., horizontal subsurface flow (HSSF) and free water surface (FWS)) were examined in both rainy and dry seasons in Thailand. A pilot-scale CW planted with cattail was installed at a landfill site in Thailand. With HSSF, the CW substantially removed pollutants from the landfill leachate without the need to harvest plants, whereas with FWS, it only slightly removed pollutants. Under both flow patterns, the CW significantly reduced the leachate volume to a greater extent than surface evaporation, which is regarded as an effect of the storage pond. Additionally, water reduction occurred regardless of season and precipitation, within the range 0-9 mm d(-1). In the case of low feeding frequency, water reduction by the CW with HSSF was lower than that with FWS. However, high feeding frequency improved water reduction by the CW with HSSF and resulted in a similar reduction to that observed with FWS, which exhibited maximum evapotranspiration. In terms of water reduction, with both HSSF in conjunction with high frequency feeding and FWS, the CW provided a high degree of evapotranspiration. However, pollutant removal efficiencies with HSSF were higher than for FWS. The present study suggested that CWs with HSSF and high frequency feeding could be useful for the prevention of uncontrollable dispersion of polluted leachate in the tropical climate zone. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Centrifugal compressor modifications and their effect on high-frequency pipe wall vibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Motriuk, R.W.; Harvey, D.P.

    1998-08-01

    High-frequency pulsation generated by centrifugal compressors, with pressure wave-lengths much smaller than the attached pipe diameter, can cause fatigue failures of the compressor internals, impair compressor performance, and damage the attached compressor piping. There are numerous sources producing pulsation in centrifugal compressors. Some of them are discussed in literature at large (Japikse, 1995; Niese, 1976). NGTL has experienced extreme high-frequency discharge pulsation and pipe wall vibration on many of its radial inlet high-flow centrifugal gas compressor facilities. These pulsations led to several piping attachment failures and compressor internal component failures while the compressor operated within the design envelope. This papermore » considers several pulsation conditions at an NGTL compression facility which resulted in unacceptable piping vibration. Significant vibration attenuation was achieved by modifying the compressor (pulsation source) through removal of the diffuser vanes and partial removal of the inlet guide vanes (IGV). Direct comparison of the changes in vibration, pulsation, and performance are made for each of the modifications. The vibration problem, probable causes, options available to address the problem, and the results of implementation are reviewed. The effects of diffuser vane removal on discharge pipe wall vibration as well as changes in compressor performance are described.« less

  20. Optimized method for manufacturing large aspheric surfaces

    NASA Astrophysics Data System (ADS)

    Zhou, Xusheng; Li, Shengyi; Dai, Yifan; Xie, Xuhui

    2007-12-01

    Aspheric optics are being used more and more widely in modern optical systems, due to their ability of correcting aberrations, enhancing image quality, enlarging the field of view and extending the range of effect, while reducing the weight and volume of the system. With optical technology development, we have more pressing requirement to large-aperture and high-precision aspheric surfaces. The original computer controlled optical surfacing (CCOS) technique cannot meet the challenge of precision and machining efficiency. This problem has been thought highly of by researchers. Aiming at the problem of original polishing process, an optimized method for manufacturing large aspheric surfaces is put forward. Subsurface damage (SSD), full aperture errors and full band of frequency errors are all in control of this method. Lesser SSD depth can be gained by using little hardness tool and small abrasive grains in grinding process. For full aperture errors control, edge effects can be controlled by using smaller tools and amendment model with material removal function. For full band of frequency errors control, low frequency errors can be corrected with the optimized material removal function, while medium-high frequency errors by using uniform removing principle. With this optimized method, the accuracy of a K9 glass paraboloid mirror can reach rms 0.055 waves (where a wave is 0.6328μm) in a short time. The results show that the optimized method can guide large aspheric surface manufacturing effectively.

  1. Fourier removal of stripe artifacts in IRAS images

    NASA Technical Reports Server (NTRS)

    Van Buren, Dave

    1987-01-01

    By working in the Fourier plane, approximate removal of stripe artifacts in IRAS images can be effected. The image of interest is smoothed and subtracted from the original, giving the high-spatial-frequency part. This 'filtered' image is then clipped to remove point sources and then Fourier transformed. Subtracting the Fourier components contributing to the stripes in this image from the Fourier transform of the original and transforming back to the image plane yields substantial removal of the stripes.

  2. Structures that Contribute to Middle-Ear Admittance in Chinchilla

    PubMed Central

    Rosowski, John J.; Ravicz, Michael E.; Songer, Jocelyn E.

    2009-01-01

    We describe measurements of middle-ear input admittance in chinchillas (Chinchilla lanigera) before and after various manipulations that define the contributions of different middle-ear components to function. The chinchilla’s middle-ear air spaces have a large effect on the low-frequency compliance of the middle ear, and removing the influences of these spaces reveals a highly admittant tympanic membrane and ossicular chain. Measurements of the admittance of the air spaces reveal that the high-degree of segmentation of these spaces has only a small effect on the admittance. Draining the cochlea further increases the middle-ear admittance at low frequencies and removes a low-frequency (less than 300 Hz) level dependence in the admittance. Spontaneous or sound-driven contractions of the middle-ear muscles in deeply anesthetized animals were associated with significant changes in middle-ear admittance. PMID:16944166

  3. Motor monitoring method and apparatus using high frequency current components

    DOEpatents

    Casada, D.A.

    1996-05-21

    A motor current analysis method and apparatus for monitoring electrical-motor-driven devices are disclosed. The method and apparatus utilize high frequency portions of the motor current spectra to evaluate the condition of the electric motor and the device driven by the electric motor. The motor current signal produced as a result of an electric motor is monitored and the low frequency components of the signal are removed by a high-pass filter. The signal is then analyzed to determine the condition of the electrical motor and the driven device. 16 figs.

  4. Motor monitoring method and apparatus using high frequency current components

    DOEpatents

    Casada, Donald A.

    1996-01-01

    A motor current analysis method and apparatus for monitoring electrical-motor-driven devices. The method and apparatus utilize high frequency portions of the motor current spectra to evaluate the condition of the electric motor and the device driven by the electric motor. The motor current signal produced as a result of an electric motor is monitored and the low frequency components of the signal are removed by a high-pass filter. The signal is then analyzed to determine the condition of the electrical motor and the driven device.

  5. Resonant ultrasound spectrometer

    DOEpatents

    Migliori, Albert; Visscher, William M.; Fisk, Zachary

    1990-01-01

    An ultrasound resonant spectrometer determines the resonant frequency spectrum of a rectangular parallelepiped sample of a high dissipation material over an expected resonant response frequency range. A sample holder structure grips corners of the sample between piezoelectric drive and receive transducers. Each transducer is mounted on a membrane for only weakly coupling the transducer to the holder structure and operatively contacts a material effective to remove system resonant responses at the transducer from the expected response range. i.e., either a material such as diamond to move the response frequencies above the range or a damping powder to preclude response within the range. A square-law detector amplifier receives the response signal and retransmits the signal on an isolated shield of connecting cabling to remove cabling capacitive effects. The amplifier also provides a substantially frequency independently voltage divider with the receive transducer. The spectrometer is extremely sensitive to enable low amplitude resonance to be detected for use in calculating the elastic constants of the high dissipation sample.

  6. Measurement of efficiency in calculus removal with a frequency-doubled Alexandrite laser on pigs' jaws

    NASA Astrophysics Data System (ADS)

    Pilgrim, Christian G.; Rechmann, Peter; Goldin, Dan S.; Hennig, Thomas

    2000-03-01

    Periodontal therapy aims in a most sufficient cleaning of tooth surfaces from supra- and subgingival calculus. As a standard dental procedure teeth are treated with ultrasonic devices. The competence of the frequency doubled Alexandrite laser for a highly effective and selective removal of calculus has been repeatedly proved. Aim of the study presented here was to determine the efficiency at simulated clinical conditions of the frequency doubled Alexandrite laser (laboratory prototype, q-switched, fiber guided, wavelength 377 nm, pulse duration 1 microsecond, pulse repetition rate 70 Hz, water cooling) by quantifying it's calculus removing efficiency. The evaluated data were compared to those obtained with an ultrasonic calculus remover. In the first part of the study sample material consisted of 23 pigs' jaws. They were divided into two groups. The teeth of one group were cleaned on their buccal surfaces using an ultrasonic device (Sonosoft Lux, KaVo, Biberach, Germany; tip #9). Than hand-guided cleaning was performed until no further improvement in cleanness was visible. Cleaning time was measured. Photographic documentation was taken before and after the treatment. The teeth in the second group were cleaned engaging a frequency doubled Alexandrite laser. Treatment time was measured and photographs were taken in the same way. In the second part of the study 21 surfaces of human teeth set up in an artificial pocket model were treated with both systems again. Measurements followed the same protocol. The results strongly support the use of the frequency doubled Alexandrite laser for calculus removal.

  7. Wavelet approach to artifact noise removal from Capacitive coupled Electrocardiograph.

    PubMed

    Lee, Seung Min; Kim, Ko Keun; Park, Kwang Suk

    2008-01-01

    Capacitive coupled Electrocardiography (ECG) is introduced as non-invasive measurement technology for ubiquitous health care and appliance are spread out widely. Although it has many merits, however, capacitive coupled ECG is very weak for motion artifacts for its non-skin-contact property. There are many studies for artifact problems which treats all artifact signals below 0.8Hz. In our capacitive coupled ECG measurement system, artifacts exist not only below 0.8Hz but also over than 10Hz. Therefore, artifact noise removal algorithm using wavelet method is tested to reject artifact-wandered signal from measured signals. It is observed that using power calculation each decimation step, artifact-wandered signal is removed as low frequency artifacts as high frequency artifacts. Although some original ECG signal is removed with artifact signal, we could level the signal quality for long term measure which shows the best quality ECG signals as we can get.

  8. Improving mental task classification by adding high frequency band information.

    PubMed

    Zhang, Li; He, Wei; He, Chuanhong; Wang, Ping

    2010-02-01

    Features extracted from delta, theta, alpha, beta and gamma bands spanning low frequency range are commonly used to classify scalp-recorded electroencephalogram (EEG) for designing brain-computer interface (BCI) and higher frequencies are often neglected as noise. In this paper, we implemented an experimental validation to demonstrate that high frequency components could provide helpful information for improving the performance of the mental task based BCI. Electromyography (EMG) and electrooculography (EOG) artifacts were removed by using blind source separation (BSS) techniques. Frequency band powers and asymmetry ratios from the high frequency band (40-100 Hz) together with those from the lower frequency bands were used to represent EEG features. Finally, Fisher discriminant analysis (FDA) combining with Mahalanobis distance were used as the classifier. In this study, four types of classifications were performed using EEG signals recorded from four subjects during five mental tasks. We obtained significantly higher classification accuracy by adding the high frequency band features compared to using the low frequency bands alone, which demonstrated that the information in high frequency components from scalp-recorded EEG is valuable for the mental task based BCI.

  9. Electric discharge for treatment of trace contaminants

    NASA Technical Reports Server (NTRS)

    Flamm, D. L.; Wydeven, T. J. (Inventor)

    1978-01-01

    A radio frequency glow discharge reactor is described for removing trace oxidizable contaminants from an oxygen bearing atmosphere. The reaction chamber is defined by an inner metal electrode facing a dielectric backed by an outer conductive electrode. In one embodiment, a conductive liquid forms the conductor of an outer electrode and cools the dielectric. A resonator coupled to a variable radio frequency source generates the high voltages for creating a glow discharge in the chamber at a predetermined pressure whereby the trace contaminants are oxidized into a few simple non-toxic products that may be easily recovered. The corresponding process for removal of trace contaminants from an oxygen-bearing atmosphere with high efficiency independent of the concentration level is also disclosed.

  10. Prevalence of Pubic Hair Grooming-Related Injuries and Identification of High-Risk Individuals in the United States.

    PubMed

    Truesdale, Matthew D; Osterberg, E Charles; Gaither, Thomas W; Awad, Mohannad A; Elmer-DeWitt, Molly A; Sutcliffe, Siobhan; Allen, Isabel; Breyer, Benjamin N

    2017-11-01

    Pubic hair grooming is a common practice that can lead to injury and morbidity. To identify demographic and behavioral risk factors associated with pubic hair grooming-related injuries to characterize individuals with high risk of injury and develop recommendations for safe grooming practices. This cross-sectional study conducted a national survey of noninstitutionalized US adults (aged 18-65 years). The web-based survey was conducted through a probability-based web panel designed to be representative of the US population. Data were collected in January 2014 and analyzed from August 1, 2016, through February 1, 2017. Grooming-related injury history (yes or no), high-frequency injuries (>5 lifetime injuries), and injury requiring medical attention. Among the 7570 participants who completed the survey (4198 men [55.5%] and 3372 women [44.5%]; mean (SD) age, 41.9 [18.9] years), 5674 of 7456 (76.1%) reported a history of grooming (66.5% of men and 85.3% of women [weighted percentages]). Grooming-related injury was reported by 1430 groomers (weighted prevalence, 25.6%), with more women sustaining an injury than men (868 [27.1%] vs 562 [23.7%]; P = .01). Laceration was the most common injury sustained (818 [61.2%]), followed by burn (307 [23.0%]) and rashes (163 [12.2%]). Common areas for grooming-related injury for men were the scrotum (378 [67.2%]), penis (196 [34.8%]), and pubis (162 [28.9%]); for women, the pubis (445 [51.3%]), inner thigh (340 [44.9%]), vagina (369 [42.5%]), and perineum (115 [13.2%]). After adjustment for age, duration of grooming, hairiness, instrument used, and grooming frequency, men who removed all their pubic hair 11 times or more during their lifespan had an increased risk for grooming injury (adjusted odds ratio [AOR], 1.97; 95% CI, 1.28-3.01; P = .002) and were prone to repeated high-frequency injuries (AOR, 3.89; 95% CI, 2.01-7.52; P < .001) compared with groomers who did not remove all their pubic hair. Women who removed all their pubic hair 11 times or more had increased odds of injury (AOR, 2.21; 95% CI, 1.53-3.19; P < .001) and high-frequency injuries (AOR, 2.98; 95% CI, 1.78-5.01; P < .001) compared with groomers who do not remove all their pubic hair. In women, waxing decreased the odds of high-frequency injuries (AOR, 0.11; 95% CI, 0.03-0.43; P = .001) compared with nonelectric blades. In total, 79 injuries among 5674 groomers (1.4%) required medical attention. Grooming frequency and degree of grooming (ie, removing all pubic hair) are independent risk factors for injury. The present data may help identify injury-prone groomers and lead to safer grooming practices.

  11. Sensing Surveillance & Navigation

    DTIC Science & Technology

    2012-03-07

    Removing Atmospheric Turbulence Goal: to restore a single high quality image from the observed sequence Prof. Peyman...Computer Sciences – Higher wavelet studies , time-scale, time-frequency transformations, Reduced Signature Targets, Low Probability of Intercept...Range Dependent Beam -patterns •Electronic Steering with Frequency Offsets •Inherent Countermeasure Capability Why? W1(t) W2(t) W3

  12. [Research in high frequency ultrasonic for degradation of azo dye wastewater containing MX-5B].

    PubMed

    Xie, Wei-Ping; Qin, Yan; Zou, Yuan; He, De-Wen; Song, Dan

    2010-09-01

    The degradation of azo dye wastewater, containing MX-5B, was investigated by using high frequency ultrasonic irradiation. The effect of different factors like the initial pH of solution, sonolysis parameters, air-blowing, Fe2+ concentration were studied, the synergistic action of complex frequency and the mechanism of degradation was explored primarily. The results show that MX-5B in aqueous solution can be degraded efficiently by ultrasonic irradiation, when the pH 3.5, ultrasonic frequency 418.3 kHz, ultrasonic power 69 W, color removal rate up to 100% in 180 min. Adding of Fe2+ and blowing air had some effects. The results also indicated that radical-oxidation controlled the ultrasonic decompose of MX-5B and MX-5B ultrasonic removal was observed to behave as pseudo-first-order kinetics under different experimental conditions tested in the present work. Comparison of UV-Vis absorption spectrums before and after treatment showed that all of the conjugate structure and part of aromatic structure were destroyed after being ultrasonic irradiation.

  13. Method of Improved Fuzzy Contrast Combined Adaptive Threshold in NSCT for Medical Image Enhancement

    PubMed Central

    Yang, Jie; Kasabov, Nikola

    2017-01-01

    Noises and artifacts are introduced to medical images due to acquisition techniques and systems. This interference leads to low contrast and distortion in images, which not only impacts the effectiveness of the medical image but also seriously affects the clinical diagnoses. This paper proposes an algorithm for medical image enhancement based on the nonsubsampled contourlet transform (NSCT), which combines adaptive threshold and an improved fuzzy set. First, the original image is decomposed into the NSCT domain with a low-frequency subband and several high-frequency subbands. Then, a linear transformation is adopted for the coefficients of the low-frequency component. An adaptive threshold method is used for the removal of high-frequency image noise. Finally, the improved fuzzy set is used to enhance the global contrast and the Laplace operator is used to enhance the details of the medical images. Experiments and simulation results show that the proposed method is superior to existing methods of image noise removal, improves the contrast of the image significantly, and obtains a better visual effect. PMID:28744464

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Bo; Zhao, Hongwei, E-mail: hwzhao@jlu.edu.cn, E-mail: khl69@163.com; Zhao, Dan

    It has always been a critical issue to understand the material removal behavior of Vibration-Assisted Machining (VAM), especially on atomic level. To find out the effects of vibration frequency on material removal response, a three-dimensional molecular dynamics (MD) model has been established in this research to investigate the effects of scratched groove, crystal defects on the surface quality, comparing with the Von Mises shear strain and tangential force in simulations during nano-scratching process. Comparisons are made among the results of simulations from different vibration frequency with the same scratching feed, depth, amplitude and crystal orientation. Copper potential in this simulationmore » is Embedded-Atom Method (EAM) potential. Interaction between copper and carbon atoms is Morse potential. Simulational results show that higher frequency can make groove smoother. Simulation with high frequency creates more dislocations to improve the machinability of copper specimen. The changing frequency does not have evident effects on Von Mises shear strain. Higher frequency can decrease the tangential force to reduce the consumption of cutting energy and tool wear. In conclusion, higher vibration frequency in VAM on mono-crystalline copper has positive effects on surface finish, machinablility and tool wear reduction.« less

  15. Removal of power line interference of space bearing vibration signal based on the morphological filter and blind source separation

    NASA Astrophysics Data System (ADS)

    Dong, Shaojiang; Sun, Dihua; Xu, Xiangyang; Tang, Baoping

    2017-06-01

    Aiming at the problem that it is difficult to extract the feature information from the space bearing vibration signal because of different noise, for example the running trend information, high-frequency noise and especially the existence of lot of power line interference (50Hz) and its octave ingredients of the running space simulated equipment in the ground. This article proposed a combination method to eliminate them. Firstly, the EMD is used to remove the running trend item information of the signal, the running trend that affect the signal processing accuracy is eliminated. Then the morphological filter is used to eliminate high-frequency noise. Finally, the components and characteristics of the power line interference are researched, based on the characteristics of the interference, the revised blind source separation model is used to remove the power line interferences. Through analysis of simulation and practical application, results suggest that the proposed method can effectively eliminate those noise.

  16. The use of impedance matching capillaries for reducing resonance in rosette infrasonic spatial filters.

    PubMed

    Hedlin, Michael A H; Alcoverro, Benoit

    2005-04-01

    Rosette spatial filters are used at International Monitoring System infrasound array sites to reduce noise due to atmospheric turbulence. A rosette filter consists of several clusters, or rosettes, of low-impedance inlets. Acoustic energy entering each rosette of inlets is summed, acoustically, at a secondary summing manifold. Acoustic energy from the secondary manifolds are summed acoustically at a primary summing manifold before entering the microbarometer. Although rosette filters have been found to be effective at reducing infrasonic noise across a broad frequency band, resonance inside the filters reduces the effectiveness of the filters at high frequencies. This paper presents theoretical and observational evidence that the resonance inside these filters that is seen below 10 Hz is due to reflections occuring at impedance discontinuities at the primary and secondary summing manifolds. Resonance involving reflections at the inlets amplifies noise levels at frequencies above 10 Hz. This paper further reports results from theoretical and observational tests of impedance matching capillaries for removing the resonance problem. Almost total removal of resonant energy below 5 Hz was found by placing impedance matching capillaries adjacent to the secondary summing manifolds in the pipes leading to the primary summing manifold and the microbarometer. Theory and recorded data indicate that capillaries with resistance equal to the characteristic impedance of the pipe connecting the secondary and primary summing manifolds suppresses resonance but does not degrade the reception of acoustic signals. Capillaries at the inlets can be used to remove resonant energy at higher frequencies but are found to be less effective due to the high frequency of this energy outside the frequency band of interest.

  17. Sonocatalytical degradation enhancement for ibuprofen and sulfamethoxazole in the presence of glass beads and single-walled carbon nanotubes.

    PubMed

    Al-Hamadani, Yasir A J; Chu, Kyoung Hoon; Flora, Joseph R V; Kim, Do-Hyung; Jang, Min; Sohn, Jinsik; Joo, Wanho; Yoon, Yeomin

    2016-09-01

    Sonocatalytic degradation experiments were carried out to determine the effects of glass beads (GBs) and single-walled carbon nanotubes (SWNTs) on ibuprofen (IBP) and sulfamethoxazole (SMX) removal using low and high ultrasonic frequencies (28 and 1000kHz). In the absence of catalysts, the sonochemical degradation at pH 7, optimum power of 0.18WmL(-1), and a temperature of 15°C was higher (79% and 72%) at 1000kHz than at 28kHz (45% and 33%) for IBP and SMX, respectively. At the low frequency (28kHz) H2O2 production increased significantly, from 10μM (no GBs) to 86μM in the presence of GBs (0.1mm, 10gL(-1)); however, no enhancement was achieved at 1000kHz. In contrast, the H2O2 production increased from 10μM (no SWNTs) to 31μM at 28kHz and from 82μM (no SWNTs) to 111μM at 1000kHz in the presence of SWNTs (45mgL(-1)). Thus, maximum removals of IBP and SMX were obtained in the presence of a combination of GBs and SWNTs at the low frequency (94% and 88%) for 60min contact time; however, >99% and 97% removals were achieved for 40 and 60min contact times at the high frequency for IBP and SMX, respectively. The results indicate that both IBP and SMX degradation followed pseudo-first-order kinetics. Additionally, the enhanced removal of IBP and SMX in the presence of catalysts was because GBs and SWNTs increased the number of free OH radicals due to ultrasonic irradiation and the adsorption capacity increase with SWNT dispersion. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Accuracy Analysis on Large Blocks of High Resolution Images

    NASA Technical Reports Server (NTRS)

    Passini, Richardo M.

    2007-01-01

    Although high altitude frequencies effects are removed at the time of basic image generation, low altitude (Yaw) effects are still present in form of affinity/angular affinity. They are effectively removed by additional parameters. Bundle block adjustment based on properly weighted ephemeris/altitude quaternions (BBABEQ) are not enough to remove the systematic effect. Moreover, due to the narrow FOV of the HRSI, position and altitude are highly correlated making it almost impossible to separate and remove their systematic effects without extending the geometric model (Self-Calib.) The systematic effects gets evident on the increase of accuracy (in terms of RMSE at GCPs) for looser and relaxed ground control at the expense of large and strong block deformation with large residuals at check points. Systematic errors are most freely distributed and their effects propagated all over the block.

  19. Method to suppress DDFS spurious signals in a frequency-hopping synthesizer with DDFS-driven PLL architecture.

    PubMed

    Kwon, Kun-Sup; Yoon, Won-Sang

    2010-01-01

    In this paper we propose a method of removing from synthesizer output spurious signals due to quasi-amplitude modulation and superposition effect in a frequency-hopping synthesizer with direct digital frequency synthesizer (DDFS)-driven phase-locked loop (PLL) architecture, which has the advantages of high frequency resolution, fast transition time, and small size. There are spurious signals that depend on normalized frequency of DDFS. They can be dominant if they occur within the PLL loop bandwidth. We suggest that such signals can be eliminated by purposefully creating frequency errors in the developed synthesizer.

  20. Dual-sensitivity profilometry with defocused projection of binary fringes.

    PubMed

    Garnica, G; Padilla, M; Servin, M

    2017-10-01

    A dual-sensitivity profilometry technique based on defocused projection of binary fringes is presented. Here, two sets of fringe patterns with a sinusoidal profile are produced by applying the same analog low-pass filter (projector defocusing) to binary fringes with a high- and low-frequency spatial carrier. The high-frequency fringes have a binary square-wave profile, while the low-frequency binary fringes are produced with error-diffusion dithering. The binary nature of the binary fringes removes the need for calibration of the projector's nonlinear gamma. Working with high-frequency carrier fringes, we obtain a high-quality wrapped phase. On the other hand, working with low-frequency carrier fringes we found a lower-quality, nonwrapped phase map. The nonwrapped estimation is used as stepping stone for dual-sensitivity temporal phase unwrapping, extending the applicability of the technique to discontinuous (piecewise continuous) surfaces. We are proposing a single defocusing level for faster high- and low-frequency fringe data acquisition. The proposed technique is validated with experimental results.

  1. A new laparoscopic-assisted hepatectomy (LAH) utilizing radiofrequency ablation and high-frequency electrocautery.

    PubMed

    Miyazawa, Mitsuo; Torii, Takahiro; Toshimitsu, Yasuko; Okada, Katsuya; Ogawa, Nobuji; Shinozuka, Nozomi; Koyama, Isamu

    2006-01-01

    Compared to tumors located at the edge of the liver, tumors located directly on the liver surface are often difficult to resect, especially when the organ is cirrhotic. To remove tumors at this location, our group has developed a round high-frequency electrosurgical knife that allows hemispherical resection of the liver tissue. This study describes a new laparoscopic-assisted hepatectomy utilizing radiofrequency ablation of the tissue surrounding the tumor and high-frequency electrocautery. When compared with the laparoscopic hepatectomy, this new procedure seems to offer a safer, more effective, and less time-consuming means of resecting tumors on the liver surface. (c) 2005 Wiley-Liss, Inc.

  2. Adaptive multitaper time-frequency spectrum estimation

    NASA Astrophysics Data System (ADS)

    Pitton, James W.

    1999-11-01

    In earlier work, Thomson's adaptive multitaper spectrum estimation method was extended to the nonstationary case. This paper reviews the time-frequency multitaper method and the adaptive procedure, and explores some properties of the eigenvalues and eigenvectors. The variance of the adaptive estimator is used to construct an adaptive smoother, which is used to form a high resolution estimate. An F-test for detecting and removing sinusoidal components in the time-frequency spectrum is also given.

  3. 78 FR 30873 - Takes of Marine Mammals Incidental to Specified Activities; Taking Marine Mammals Incidental to a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-23

    ..., administered by Space and Naval Warfare Systems Command (SPAWAR) Systems Center (SSC), would be moved... stream of water under high pressure) would be another option to loosen piles that could not be removed... which are frequency, wavelength, velocity, and amplitude. Frequency is the number of pressure waves that...

  4. Industrial filter bags cleaned by high-frequency vibration: A concept

    NASA Technical Reports Server (NTRS)

    Kooy, A. V.

    1973-01-01

    System holds filter bag around fine-mesh metal screen and vibrates screen at its resonant frequency. This removes deposited byproducts and protects bag fibers from damaging forces. Because filter bags represent 20 to 40% of any industrial filtering investment, this method of extending bag life should be of interest to those responsible for plant maintenance.

  5. Endometrial ablation

    MedlinePlus

    ... tissue can be removed using: High frequency radio waves Laser energy Heated fluids Balloon therapy Freezing Electrical ... eds. Atlas of pelvic anatomy and gynecologic surgery . 4th ed. Philadelphia, PA: Elsevier; 2016:chap 110. Carlson ...

  6. High-throughput machining using high average power ultrashort pulse lasers and ultrafast polygon scanner

    NASA Astrophysics Data System (ADS)

    Schille, Joerg; Schneider, Lutz; Streek, André; Kloetzer, Sascha; Loeschner, Udo

    2016-03-01

    In this paper, high-throughput ultrashort pulse laser machining is investigated on various industrial grade metals (Aluminium, Copper, Stainless steel) and Al2O3 ceramic at unprecedented processing speeds. This is achieved by using a high pulse repetition frequency picosecond laser with maximum average output power of 270 W in conjunction with a unique, in-house developed two-axis polygon scanner. Initially, different concepts of polygon scanners are engineered and tested to find out the optimal architecture for ultrafast and precision laser beam scanning. Remarkable 1,000 m/s scan speed is achieved on the substrate, and thanks to the resulting low pulse overlap, thermal accumulation and plasma absorption effects are avoided at up to 20 MHz pulse repetition frequencies. In order to identify optimum processing conditions for efficient high-average power laser machining, the depths of cavities produced under varied parameter settings are analyzed and, from the results obtained, the characteristic removal values are specified. The maximum removal rate is achieved as high as 27.8 mm3/min for Aluminium, 21.4 mm3/min for Copper, 15.3 mm3/min for Stainless steel and 129.1 mm3/min for Al2O3 when full available laser power is irradiated at optimum pulse repetition frequency.

  7. Reduction of a grid moiré pattern by integrating a carbon-interspaced high precision x-ray grid with a digital radiographic detector.

    PubMed

    Yoon, Jai-Woong; Park, Young-Guk; Park, Chun-Joo; Kim, Do-Il; Lee, Jin-Ho; Chung, Nag-Kun; Choe, Bo-Young; Suh, Tae-Suk; Lee, Hyoung-Koo

    2007-11-01

    The stationary grid commonly used with a digital x-ray detector causes a moiré interference pattern due to the inadequate sampling of the grid shadows by the detector pixels. There are limitations with the previous methods used to remove the moiré such as imperfect electromagnetic interference shielding and the loss of image information. A new method is proposed for removing the moiré pattern by integrating a carbon-interspaced high precision x-ray grid with high grid line uniformity with the detector for frequency matching. The grid was aligned to the detector by translating and rotating the x-ray grid with respect to the detector using microcontrolled alignment mechanism. The gap between the grid and the detector surface was adjusted with micrometer precision to precisely match the projected grid line pitch to the detector pixel pitch. Considering the magnification of the grid shadows on the detector plane, the grids were manufactured such that the grid line frequency was slightly higher than the detector sampling frequency. This study examined the factors that affect the moiré pattern, particularly the line frequency and displacement. The frequency of the moiré pattern was found to be sensitive to the angular displacement of the grid with respect to the detector while the horizontal translation alters the phase but not the moiré frequency. The frequency of the moiré pattern also decreased with decreasing difference in frequency between the grid and the detector, and a moiré-free image was produced after complete matching for a given source to detector distance. The image quality factors including the contrast, signal-to-noise ratio and uniformity in the images with and without the moiré pattern were investigated.

  8. Physiological and behavioural responses associated with feather removal in Gallus gallus var domesticus.

    PubMed

    Gentle, M J; Hunter, L N

    1991-01-01

    Electroencephalographic, cardiovascular and behavioural parameters were examined in Gallus gallus var domesticus in response to feather removal. The progressive removal of feathers resulted in marked changes in the bird's behaviour from an alert agitated response following the initial removals to periods of crouching immobility following successive removals. During the periods of immobility the birds showed a high amplitude low frequency EEG pattern and successive removals resulted in a progressive increase in the total duration of this activity in the two minutes after removal. The heart rate response to feather removal was variable whereas the blood pressure always increased and this increase was followed by a gradual return to pre-stimulus levels. There were no consistent cardiovascular responses related to the immobility. It was concluded that feather removal is likely to be painful to the bird and feather removal by flockmates can be categorised as a welfare problem.

  9. A review of concepts regarding the origin of respiratory muscle fatigue

    NASA Astrophysics Data System (ADS)

    Kuraszkiewicz, Bożena; Piotrkiewicz, Maria

    2011-01-01

    In this review, the classification of respiratory muscle fatigue from the perspective of its origin is presented. The fatigue is classified as central or peripheral, and the latter further subdivided into high- and low-frequency fatigue. However, muscle fatigue is a complex process and all three types of fatigue probably occur simultaneously in the overloaded respiratory muscles. The relative importance of each type depends on the duration of respiratory loading and other physiological variables. However, central and high-frequency fatigue resolve rapidly once muscle overload is removed, whereas low-frequency fatigue persists over long time.

  10. Portable vibration exciter

    NASA Technical Reports Server (NTRS)

    Beecher, L. C.; Williams, F. T.

    1970-01-01

    Gas-driven vibration exciter produces a sinusoidal excitation function controllable in frequency and in amplitude. It allows direct vibration testing of components under normal loads, removing the possibility of component damage due to high static pressure.

  11. 47 CFR 101.111 - Emission limitations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... using transmissions other than those employing digital modulation techniques: (i) On any frequency removed from the assigned frequency by more than 50 percent up to and including 100 percent of the authorized bandwidth: At least 25 decibels; (ii) On any frequency removed from the assigned frequency by more...

  12. Removal of Escherichia coli via low frequency electromagnetic field in riverbank filtration system.

    NASA Astrophysics Data System (ADS)

    Selamat, Rossitah; Abustan, Ismail; Rizal Arshad, Mohd; Mokhtar Kamal, Nurul Hana

    2018-04-01

    The removal of Escherichia coli (E. coli) via low frequency of electromagnetic field (LF-EMF) with different magnetic field was studied. LF-EMF is known as a high magnetic susceptibility method, which could affect E. coli growth without the usage of chemicals. The aim of this study was to investigate the removal of E. coli by using LF-EMF in water abstraction for the riverbank filtration (RBF) application. The effect of LF-EMF with the intensity of 2 to 10mT and 50Hz on coiled column of 1mm copper wire at 1 to 6 hours was assessed. The removal of E. coli after exposing to LF-EMF on the column model was measured using most probable number (MPN/100mL) and colonies forming unit (CFU/100mL) methods. Water flows into the column were varied up to 6 hours and with flowrate of 100 mL/min. Experimental results demonstrate that 100% of E. coli was removed at 8mT after 6 hours exposure. The magnetic field at 10mT removed 100% of E. coli after 4 hours exposure. The results obtained in this study proved that the LF-EMF was efficient in E. coli removal from RBF system. These finding indicated that the LF-EMF intensities and time of exposure can affect the removal of E. coli.

  13. Selective ablation of dental calculus with a frequency-doubled Alexandrite laser

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas

    1996-01-01

    The aim of the study was the selective removal of dental calculus by means of pulsed lasers. In a first approach the optical characteristics of subgingival calculus were calculated using fluorescence emission spectroscopy (excitation laser: N2-laser, wavelength 337 nm, pulse duration 4 ns). Subgingival calculus seems to absorb highly in the ultraviolet spectral region up to 420 nm. According to these measurements a frequency doubled Alexandrite-laser (wavelength 377 nm, pulse duration 100 ns, repetition rate 110 Hz) was used to irradiate calculus located on enamel, at the cementum enamel junction and on the root surface (located on dentin or on cementum). Irradiation was performed perpendicular to the root surface with a laser fluence of 1 Jcm-2. During the irradiation procedure an effective water cooling-system was engaged. Histological investigations were done on undecalcified sections. As a result, engaging low fluences allows a fast and strictly selective removal of subgingival calculus. Even more the investigations revealed that supragingival calculus can be removed in a strictly selective manner engaging a frequency doubled Alexandrite-laser. No adverse side effects to the surrounding tissues could be found.

  14. Noise modeling and analysis of an IMU-based attitude sensor: improvement of performance by filtering and sensor fusion

    NASA Astrophysics Data System (ADS)

    K., Nirmal; A. G., Sreejith; Mathew, Joice; Sarpotdar, Mayuresh; Suresh, Ambily; Prakash, Ajin; Safonova, Margarita; Murthy, Jayant

    2016-07-01

    We describe the characterization and removal of noises present in the Inertial Measurement Unit (IMU) MPU- 6050, which was initially used in an attitude sensor, and later used in the development of a pointing system for small balloon-borne astronomical payloads. We found that the performance of the IMU degraded with time because of the accumulation of different errors. Using Allan variance analysis method, we identified the different components of noise present in the IMU, and verified the results by the power spectral density analysis (PSD). We tried to remove the high-frequency noise using smooth filters such as moving average filter and then Savitzky Golay (SG) filter. Even though we managed to filter some high-frequency noise, these filters performance wasn't satisfactory for our application. We found the distribution of the random noise present in IMU using probability density analysis and identified that the noise in our IMU was white Gaussian in nature. Hence, we used a Kalman filter to remove the noise and which gave us good performance real time.

  15. Research on the magnetorheological finishing (MRF) technology with dual polishing heads

    NASA Astrophysics Data System (ADS)

    Huang, Wen; Zhang, Yunfei; He, Jianguo; Zheng, Yongcheng; Luo, Qing; Hou, Jing; Yuan, Zhigang

    2014-08-01

    Magnetorheological finishing (MRF) is a key polishing technique capable of rapidly converging to the required surface figure. Due to the deficiency of general one-polishing-head MRF technology, a dual polishing heads MRF technology was studied and a dual polishing heads MRF machine with 8 axes was developed. The machine has the ability to manufacture large aperture optics with high figure accuracy. The large polishing head is suitable for polishing large aperture optics, controlling large spatial length's wave structures, correcting low-medium frequency errors with high removal rates. While the small polishing head has more advantages in manufacturing small aperture optics, controlling small spatial wavelength's wave structures, correcting mid-high frequency and removing nanoscale materials. Material removal characteristic and figure correction ability for each of large and small polishing head was studied. Each of two polishing heads respectively acquired stable and valid polishing removal function and ultra-precision flat sample. After a single polishing iteration using small polishing head, the figure error in 45mm diameter of a 50 mm diameter plano optics was significantly improved from 0.21λ to 0.08λ by PV (RMS 0.053λ to 0.015λ). After three polishing iterations using large polishing head , the figure error in 410mm×410mm of a 430mm×430mm large plano optics was significantly improved from 0.40λ to 0.10λ by PV (RMS 0.068λ to 0.013λ) .This results show that the dual polishing heads MRF machine not only have good material removal stability, but also excellent figure correction capability.

  16. Increased fusiform area activation in schizophrenia during processing of spatial frequency-degraded faces, as revealed by fMRI.

    PubMed

    Silverstein, S M; All, S D; Kasi, R; Berten, S; Essex, B; Lathrop, K L; Little, D M

    2010-07-01

    People with schizophrenia demonstrate perceptual organization impairments, and these are thought to contribute to their face processing difficulties. We examined the neural substrates of emotionally neutral face processing in schizophrenia by investigating neural activity under three stimulus conditions: faces characterized by the full spectrum of spatial frequencies, faces with low spatial frequency information removed [high spatial frequency (HSF) condition], and faces with high spatial frequency information removed [low spatial frequency (LSF) condition]. Face perception in the HSF condition is more reliant on local feature processing whereas perception in the LSF condition requires greater reliance on global form processing. Past studies of perceptual organization in schizophrenia indicate that patients perform relatively more poorly with degraded stimuli but also that, when global information is absent, patients may perform better than controls because of their relatively increased ability to initially process individual features. Therefore, we hypothesized that people with schizophrenia (n=14) would demonstrate greater face processing difficulties than controls (n=13) in the LSF condition, whereas they would demonstrate a smaller difference or superior performance in the HSF condition. In a gender-discrimination task, behavioral data indicated high levels of accuracy for both groups, with a trend toward an interaction involving higher patient performance in the HSF condition and poorer patient performance in the LSF condition. Patients demonstrated greater activity in the fusiform gyrus compared to controls in both degraded conditions. These data suggest that impairments in basic integration abilities may be compensated for by relatively increased activity in this region.

  17. Broadband unidirectional ultrasound propagation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinha, Dipen N.; Pantea, Cristian

    A passive, linear arrangement of a sonic crystal-based apparatus and method including a 1D sonic crystal, a nonlinear medium, and an acoustic low-pass filter, for permitting unidirectional broadband ultrasound propagation as a collimated beam for underwater, air or other fluid communication, are described. The signal to be transmitted is first used to modulate a high-frequency ultrasonic carrier wave which is directed into the sonic crystal side of the apparatus. The apparatus processes the modulated signal, whereby the original low-frequency signal exits the apparatus as a collimated beam on the side of the apparatus opposite the sonic crystal. The sonic crystalmore » provides a bandpass acoustic filter through which the modulated high-frequency ultrasonic signal passes, and the nonlinear medium demodulates the modulated signal and recovers the low-frequency sound beam. The low-pass filter removes remaining high-frequency components, and contributes to the unidirectional property of the apparatus.« less

  18. Processing of Fear and Anger Facial Expressions: The Role of Spatial Frequency

    PubMed Central

    Comfort, William E.; Wang, Meng; Benton, Christopher P.; Zana, Yossi

    2013-01-01

    Spatial frequency (SF) components encode a portion of the affective value expressed in face images. The aim of this study was to estimate the relative weight of specific frequency spectrum bandwidth on the discrimination of anger and fear facial expressions. The general paradigm was a classification of the expression of faces morphed at varying proportions between anger and fear images in which SF adaptation and SF subtraction are expected to shift classification of facial emotion. A series of three experiments was conducted. In Experiment 1 subjects classified morphed face images that were unfiltered or filtered to remove either low (<8 cycles/face), middle (12–28 cycles/face), or high (>32 cycles/face) SF components. In Experiment 2 subjects were adapted to unfiltered or filtered prototypical (non-morphed) fear face images and subsequently classified morphed face images. In Experiment 3 subjects were adapted to unfiltered or filtered prototypical fear face images with the phase component randomized before classifying morphed face images. Removing mid frequency components from the target images shifted classification toward fear. The same shift was observed under adaptation condition to unfiltered and low- and middle-range filtered fear images. However, when the phase spectrum of the same adaptation stimuli was randomized, no adaptation effect was observed. These results suggest that medium SF components support the perception of fear more than anger at both low and high level of processing. They also suggest that the effect at high-level processing stage is related more to high-level featural and/or configural information than to the low-level frequency spectrum. PMID:23637687

  19. Effect of sample stratification on dairy GWAS results

    PubMed Central

    2012-01-01

    Background Artificial insemination and genetic selection are major factors contributing to population stratification in dairy cattle. In this study, we analyzed the effect of sample stratification and the effect of stratification correction on results of a dairy genome-wide association study (GWAS). Three methods for stratification correction were used: the efficient mixed-model association expedited (EMMAX) method accounting for correlation among all individuals, a generalized least squares (GLS) method based on half-sib intraclass correlation, and a principal component analysis (PCA) approach. Results Historical pedigree data revealed that the 1,654 contemporary cows in the GWAS were all related when traced through approximately 10–15 generations of ancestors. Genome and phenotype stratifications had a striking overlap with the half-sib structure. A large elite half-sib family of cows contributed to the detection of favorable alleles that had low frequencies in the general population and high frequencies in the elite cows and contributed to the detection of X chromosome effects. All three methods for stratification correction reduced the number of significant effects. EMMAX method had the most severe reduction in the number of significant effects, and the PCA method using 20 principal components and GLS had similar significance levels. Removal of the elite cows from the analysis without using stratification correction removed many effects that were also removed by the three methods for stratification correction, indicating that stratification correction could have removed some true effects due to the elite cows. SNP effects with good consensus between different methods and effect size distributions from USDA’s Holstein genomic evaluation included the DGAT1-NIBP region of BTA14 for production traits, a SNP 45kb upstream from PIGY on BTA6 and two SNPs in NIBP on BTA14 for protein percentage. However, most of these consensus effects had similar frequencies in the elite and average cows. Conclusions Genetic selection and extensive use of artificial insemination contributed to overlapped genome, pedigree and phenotype stratifications. The presence of an elite cluster of cows was related to the detection of rare favorable alleles that had high frequencies in the elite cluster and low frequencies in the remaining cows. Methods for stratification correction could have removed some true effects associated with genetic selection. PMID:23039970

  20. High frequency measures of OHC nonlinear capacitance (NLC) and their significance: Why measures stray away from predictions

    NASA Astrophysics Data System (ADS)

    Santos-Sacchi, Joseph

    2018-05-01

    Measures of membrane capacitance (Cm) can be used to assess important characteristics of voltage-dependent membrane proteins (e.g., channels and transporters). In particular, a protein's time-dependent voltage-sensor charge movement is equivalently represented as a frequency-dependent component of Cm, telling much about the kinetics of the protein's conformational behavior. Recently, we have explored the frequency dependence of OHC voltage-dependent capacitance (aka nonlinear capacitance, NLC) to query rates of conformational switching within prestin (SLC26a5), the cell's lateral membrane molecular motor 1. Following removal of confounding stray capacitance effects, high frequency Cm measures using wide-band stimuli accurately reveal unexpected low pass behavior in prestin's molecular motions.

  1. Treatment of late time instabilities in finite-difference EMP scattering codes

    NASA Astrophysics Data System (ADS)

    Simpson, L. T.; Holland, R.; Arman, S.

    1982-12-01

    Constraints applicable to a finite difference mesh for solution of Maxwell's equations are defined. The equations are applied in the time domain for computing electromagnetic coupling to complex structures, e.g., rectangular, cylindrical, or spherical. In a spatially varying grid, the amplitude growth of high frequency waves becomes exponential through multiple reflections from the outer boundary in cases of late-time solution. The exponential growth of the numerical noise exceeds the value of the real signal. The correction technique employs an absorbing surface and a radiating boundary, along with tailored selection of the grid mesh size. High frequency noise is removed through use of a low-pass digital filter, a linear least squares fit is made to thy low frequency filtered response, and the original, filtered, and fitted data are merged to preserve the high frequency early-time response.

  2. Real-Time and High-Resolution 3D Face Measurement via a Smart Active Optical Sensor.

    PubMed

    You, Yong; Shen, Yang; Zhang, Guocai; Xing, Xiuwen

    2017-03-31

    The 3D measuring range and accuracy in traditional active optical sensing, such as Fourier transform profilometry, are influenced by the zero frequency of the captured patterns. The phase-shifting technique is commonly applied to remove the zero component. However, this phase-shifting method must capture several fringe patterns with phase difference, thereby influencing the real-time performance. This study introduces a smart active optical sensor, in which a composite pattern is utilized. The composite pattern efficiently combines several phase-shifting fringes and carrier frequencies. The method can remove zero frequency by using only one pattern. Model face reconstruction and human face measurement were employed to study the validity and feasibility of this method. Results show no distinct decrease in the precision of the novel method unlike the traditional phase-shifting method. The texture mapping technique was utilized to reconstruct a nature-appearance 3D digital face.

  3. Real-Time and High-Resolution 3D Face Measurement via a Smart Active Optical Sensor

    PubMed Central

    You, Yong; Shen, Yang; Zhang, Guocai; Xing, Xiuwen

    2017-01-01

    The 3D measuring range and accuracy in traditional active optical sensing, such as Fourier transform profilometry, are influenced by the zero frequency of the captured patterns. The phase-shifting technique is commonly applied to remove the zero component. However, this phase-shifting method must capture several fringe patterns with phase difference, thereby influencing the real-time performance. This study introduces a smart active optical sensor, in which a composite pattern is utilized. The composite pattern efficiently combines several phase-shifting fringes and carrier frequencies. The method can remove zero frequency by using only one pattern. Model face reconstruction and human face measurement were employed to study the validity and feasibility of this method. Results show no distinct decrease in the precision of the novel method unlike the traditional phase-shifting method. The texture mapping technique was utilized to reconstruct a nature-appearance 3D digital face. PMID:28362349

  4. Removal of particulate matter emitted from a subway tunnel using magnetic filters.

    PubMed

    Son, Youn-Suk; Dinh, Trieu-Vuong; Chung, Sang-Gwi; Lee, Jai-Hyo; Kim, Jo-Chun

    2014-01-01

    We removed particulate matter (PM) emitted from a subway tunnel using magnetic filters. A magnetic filter system was installed on the top of a ventilation opening. Magnetic field density was increased by increasing the number of permanent magnet layers to determine PM removal characteristics. Moreover, the fan's frequency was adjusted from 30 to 60 Hz to investigate the effect of wind velocity on PM removal efficiency. As a result, PM removal efficiency increased as the number of magnetic filters or fan frequency increased. We obtained maximum removal efficiency of PM10 (52%), PM2.5 (46%), and PM1 (38%) at a 60 Hz fan frequency using double magnetic filters. We also found that the stability of the PM removal efficiency by the double filter (RSD, 3.2-5.8%) was higher than that by a single filter (10.9-24.5%) at all fan operating conditions.

  5. Artifactual responses when recording auditory steady-state responses.

    PubMed

    Small, Susan A; Stapells, David R

    2004-12-01

    The goal of this study was to investigate, in hearing-impaired participants who could not hear the stimuli, the possibility of artifactual auditory steady-state responses (ASSRs) when stimuli are presented at high intensities. ASSRs to single (60 dB HL) and multiple (20 to 50 dB HL; 500 to 4000 Hz) bone-conduction stimuli as well as single 114 to 120 dB HL air-conduction stimuli, were obtained using the Rotman MASTER system, using analog-to-digital (A/D) conversion rates of 500, 1000, and 1250 Hz. Responses (p < 0.05) were considered artifactual when their numbers exceeded that expected by chance. In some conditions, we also obtained ASSRs to "alternated" stimuli (stimuli inverted and ASSRs to the two polarities averaged). A total of 17 subjects were tested. Bone conduction results: 500 Hz A/D rate: Large-amplitude (43 to 1558 nV) artifactual ASSRs were seen at 40 and 50 dB HL for the 500 Hz carrier frequency. Smaller responses (28 to 53 nV) were also recorded at 20 dB HL for the 500 Hz carrier frequency. Artifactual ASSRs (17 to 62 nV) were seen at 40 dB HL and above for the 1000 Hz carrier frequency and at 50 dB HL for the 2000 Hz carrier frequency. Alternating the stimulus polarity decreased the amplitude and occurrence of these artifactual responses but did not eliminate responses for the 500 Hz carrier frequency at 40 dB HL and above. No artifactual responses were recorded for 4000 Hz stimuli for any condition. 1000 Hz A/D rate: Artifactual ASSRs (15 to 523 nV) were seen at 50 dB HL and above for the 500 Hz carrier frequency and 40 dB HL and above for the 1000 Hz carrier frequency. Artifactual responses were also obtained at 50 dB HL for a 2000 Hz carrier frequency but not at lower levels. Artifactual responses were not seen for the 4000 Hz carrier frequency. Alternating the stimulus polarity removed the responses for the 1000 and 2000 Hz carrier frequencies but did not change the results for the 500 Hz carrier frequency. 1250 Hz A/D rate: Artifactual ASSRs (16 to 220 nV) were seen at 50 dB HL and above for the 500 Hz carrier frequency and 60 dB HL and above for the 1000 Hz carrier frequency. Alternating the stimulus polarity removed the responses for the 1000 Hz carrier frequency but did not change the results for the 500 Hz carrier frequency. There were no artifactual responses at 2000 and 4000 Hz. Air conduction results: 500 Hz A/D rate: Artifactual ASSRs (49 to 153 nV) were seen for 114 to 120 dB HL stimuli for 500 and 1000 Hz carrier frequencies. Alternating the stimulus polarity removed these responses. There were no artifactual responses at 2000 and 4000 Hz. 1000 and 1250 Hz A/D rates: Artifactual ASSRs (19 to 55 nV) were seen for a 120 dB HL stimulus for a 1000 Hz carrier. Alternating the stimulus polarity removed these responses. High-intensity air- or bone-conduction stimuli can produce spurious ASSRs, especially for 500 and 1000 Hz carrier frequencies. High-amplitude stimulus artifact can result in energy that is aliased to exactly the modulation frequency. Choice of signal conditioning (electroencephalogram filter slope and low-pass cutoff) and processing (A/D rate) can avoid spurious responses due to aliasing. However, artifactual responses due to other causes may still occur for bone-conduction stimuli 50 dB HL and higher (and possibly for high-level air conduction). Because the phases of these spurious responses do not invert with inversion of stimulus, the possibility of nonauditory physiologic responses cannot be ruled out. The clinical implications of these results are that artifactual responses may occur for any patient for bone-conduction stimuli at levels greater than 40 dB HL and for high-intensity air-conduction stimuli used to assess patients with profound hearing loss.

  6. Rapid and selective updating of the target template in visual search.

    PubMed

    Sha, Li Z; Remington, Roger W; Jiang, Yuhong V

    2017-01-01

    Frequent target stimuli are detected more rapidly than infrequent ones. Here, we examined whether the frequency effect reflected durable attentional biases toward frequent target features, and whether the effect was confined to featural properties that defined the target. Participants searched for two specific target colors among distractors of heterogeneous colors and reported the line orientation of the target. The target was more often in one specific feature (e.g., a specific color or a specific orientation) than another in a training phase. This frequency difference was removed or reversed in a testing phase. Experiments 1 and 2 showed that when frequency differences were introduced to the target's defining feature, participants more rapidly found the high-frequency target than the low-frequency target. However, changes in attention were not durable-the search advantage vanished immediately when the frequency differences were removed. Experiments 3-5 showed that only featural properties that defined the target facilitated search of the more frequent feature. Features that did not define the target, such as the target feature that participants reported, sped up response but did not facilitate search. These data showed that when searching for multiple targets in a feature search task, people selectively and rapidly adapt to the frequency in the target's defining feature.

  7. The Conference Proceedings of the 1999 Air Transport Research Group (ATRG) of the WCTR Society. Volume 2

    NASA Technical Reports Server (NTRS)

    Zhang, Anming (Editor); Bowen Brent D. (Editor)

    1999-01-01

    In this paper, we develop a model with which allows us to measure not only the changes in equilibrium outcomes and welfare consequences of liberalizing a bilateral air transport agreement, but also the distribution of the gains and losses to carriers and consumers of each bilateral country and those of the third foreign countries. Our model also allows to measure the effects of changes in a bilateral agreement on the amount of traffic diversion between the direct bilateral routes and the indirect routes via a third country. We also provide an extension of our model to a case of oligopoly market outcome (Coumot Nash equilibrium). In our model, quality aspects are treated in the framework of hedonic price theory by specifying the quality-adjusted price (quantity) as a multiplication of the observed price (quantity) by the reciprocal quality index function (the quality index function). Numerical simulations were conducted to measure the effects of changing the following major policy levers in a bilateral air transport agreement: 1) Removing price regulation while retaining frequency and entry restrictions; 2) Removing price and entry regulation while retaining frequency restrictions; 3) Removing frequency regulations while retaining price and entry regulations; 4) Removing frequency and entry regulations while retaining price regulation; 5) Removing price and frequency regulations while retaining entry restriction; and 6) Removing all price, frequency and entry regulations (de facto, open skies).

  8. Dynamics of Debris Supply and Removal from Coastal Cliffs

    NASA Astrophysics Data System (ADS)

    Dickson, M. E.; Vann Jones, E. C.; Payo, A.; Matsumoto, H.

    2016-12-01

    Progress in obtaining a morphodynamic understanding of rocky shores has been limited by slow rates of change and lack of preserved evidence of erosion processes. As a result we do not have a detailed understanding of the relative contributions of failure events across the magnitude-frequency spectrum. This talk describes field experiments, supported by simple stock-flow modelling, on a coastal cliff-face in eastern New Zealand. Key features of this site are that it is composed of near-homogenous rapidly eroding mudstone, and it is fronted by a wide intertidal rock platform that results in the cliff toe being exposed to waves every high tide. Several techniques were used to measure the cliff debris supply-removal system. Sediment traps at the cliff toe directly recorded rates of debris supply from the cliff-face at five discrete locations. Repeated high-resolution terrestrial laser scans over several consecutive low-tide stages documented changes in cliff-toe talus volumes along 50m of shoreline. Optical back-scatter sensors located on the rock shore platform in front of the cliff toe constrained the timing of talus-debris resuspension during tidal inundation of the cliff toe. Wave pressure gauges were used to characterise the wave field acting on the cliff. Results demonstrate that high-resolution (<5mm) laser scanning can meaningfully characterise rates of coastal cliff erosion at the very high-frequency low-magnitude end of the erosion spectrum. We find that rates of debris supply from the cliff face are dependent on the subaerial weathering system, in particular wetting and drying and associated expansion and contraction of clay minerals within the cliff rock. Rates of debris removal from the cliff toe depend on tide and wave conditions: even under low wave-energy conditions, waves at infragravity frequencies can access the cliff toe at high tide leading to sediment suspension. We explore the basic feedback structure of cliff, talus and debris removal using a simple stock-flow model, and discuss implications for progressive (ongoing) cliff erosion in the presence of an ever-widening shore platform.

  9. MULTI-FLUID APPROACH TO HIGH-FREQUENCY WAVES IN PLASMAS. I. SMALL-AMPLITUDE REGIME IN FULLY IONIZED MEDIUM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martínez-Gómez, David; Soler, Roberto; Terradas, Jaume, E-mail: david.martinez@uib.es

    Ideal magnetohydrodynamics (MHD) provides an accurate description of low-frequency Alfvén waves in fully ionized plasmas. However, higher-frequency waves in many plasmas of the solar atmosphere cannot be correctly described by ideal MHD and a more accurate model is required. Here, we study the properties of small-amplitude incompressible perturbations in both the low- and the high-frequency ranges in plasmas composed of several ionized species. We use a multi-fluid approach and take into account the effects of collisions between ions and the inclusion of Hall’s term in the induction equation. Through the analysis of the corresponding dispersion relations and numerical simulations, wemore » check that at high frequencies ions of different species are not as strongly coupled as in the low-frequency limit. Hence, they cannot be treated as a single fluid. In addition, elastic collisions between the distinct ionized species are not negligible for high-frequency waves, since an appreciable damping is obtained. Furthermore, Coulomb collisions between ions remove the cyclotron resonances and the strict cutoff regions, which are present when collisions are not taken into account. The implications of these results for the modeling of high-frequency waves in solar plasmas are discussed.« less

  10. Which lamp will be optimum to eye? Incandescent, fluorescent or LED etc

    PubMed Central

    Chen, Liang; Zhang, Xiao-Wei

    2014-01-01

    Low frequency flicker, high frequency flicker, strong light, strong blue light, infrared, ultraviolet, electromagnetic radiation, ripple flicker and dimming flicker produced by different lamps have negative impact on vision, eyes and health. Negative impact on eyes resulting in myopia or cataract etc: the solution is to remove all the negative factors by applying upright lighting technology and that is optimum to vision, eyes and health. PMID:24634884

  11. Which lamp will be optimum to eye? Incandescent, fluorescent or LED etc.

    PubMed

    Chen, Liang; Zhang, Xiao-Wei

    2014-01-01

    Low frequency flicker, high frequency flicker, strong light, strong blue light, infrared, ultraviolet, electromagnetic radiation, ripple flicker and dimming flicker produced by different lamps have negative impact on vision, eyes and health. Negative impact on eyes resulting in myopia or cataract etc: the solution is to remove all the negative factors by applying upright lighting technology and that is optimum to vision, eyes and health.

  12. Occurrence of 25 pharmaceuticals in Taihu Lake and their removal from two urban drinking water treatment plants and a constructed wetland.

    PubMed

    Hu, Xia-Lin; Bao, Yi-Fan; Hu, Jun-Jian; Liu, You-Yu; Yin, Da-Qiang

    2017-06-01

    Pharmaceuticals in drinking water sources have raised significant concerns due to their persistent input and potential human health risks. The seasonal occurrence of 25 pharmaceuticals including 23 antibiotics, paracetamol (PAR), and carbamazepine (CMZ) in Taihu Lake was investigated; meanwhile, the distribution and removal of these pharmaceuticals in two drinking water treatment plants (DWTPs) and a constructed wetland were evaluated. A high detection frequency (>70%) in the Taihu Lake was observed for nearly all the 25 pharmaceutics. Chlortetracycline (234.7 ng L -1 ), chloramphenicol (27.1 ng L -1 ), erythromycin (72.6 ng L -1 ), PAR (71.7 ng L -1 ), and CMZP (23.6 ng L -1 ) are compounds with both a high detection frequency (100%) and the highest concentrations, suggesting their wide use in the Taihu Basin. Higher concentrations of chloramphenicols, macrolides, PAR, and CMZP were observed in dry season than in wet season, probably due to the low flow conditions of the lake in winter and the properties of pharmaceuticals. The overall contamination levels of antibiotic pharmaceutics (0.2-74.9 ng L -1 ) in the Taihu Lake were lower than or comparable to those reported worldwide. However, for nonantibiotic pharmaceutics, PAR (45.0 ng L -1 ) and CMZP (14.5 ng L -1 ), significantly higher concentrations were observed in the Taihu Lake than at a global scale. High detection frequencies of 25 pharmaceuticals were observed in both the two DWTPs (100%) and the wetland (>60%) except for florfenicol and sulfapyridine. The removal efficacies of the studied pharmaceuticals in DWTP B with advanced treatment processes including ozonation and granular activated carbon filtration (16.7-100%) were superior to DWTP A with conventional treatment processes (2.9-100%), except for sulfonamides. Wetland C with the constructed root channel technology was efficient (24.2-100%) for removing most pharmaceuticals. This work suggests that the application of cost-effective technologies such as constructed wetlands should be considered as an efficient alternative for removing pharmaceuticals from water supply sources.

  13. Correcting length-frequency distributions for imperfect detection

    USGS Publications Warehouse

    Breton, André R.; Hawkins, John A.; Winkelman, Dana L.

    2013-01-01

    Sampling gear selects for specific sizes of fish, which may bias length-frequency distributions that are commonly used to assess population size structure, recruitment patterns, growth, and survival. To properly correct for sampling biases caused by gear and other sources, length-frequency distributions need to be corrected for imperfect detection. We describe a method for adjusting length-frequency distributions when capture and recapture probabilities are a function of fish length, temporal variation, and capture history. The method is applied to a study involving the removal of Smallmouth Bass Micropterus dolomieu by boat electrofishing from a 38.6-km reach on the Yampa River, Colorado. Smallmouth Bass longer than 100 mm were marked and released alive from 2005 to 2010 on one or more electrofishing passes and removed on all other passes from the population. Using the Huggins mark–recapture model, we detected a significant effect of fish total length, previous capture history (behavior), year, pass, year×behavior, and year×pass on capture and recapture probabilities. We demonstrate how to partition the Huggins estimate of abundance into length frequencies to correct for these effects. Uncorrected length frequencies of fish removed from Little Yampa Canyon were negatively biased in every year by as much as 88% relative to mark–recapture estimates for the smallest length-class in our analysis (100–110 mm). Bias declined but remained high even for adult length-classes (≥200 mm). The pattern of bias across length-classes was variable across years. The percentage of unadjusted counts that were below the lower 95% confidence interval from our adjusted length-frequency estimates were 95, 89, 84, 78, 81, and 92% from 2005 to 2010, respectively. Length-frequency distributions are widely used in fisheries science and management. Our simple method for correcting length-frequency estimates for imperfect detection could be widely applied when mark–recapture data are available.

  14. On the Performance of the Martin Digital Filter for High- and Low-pass Applications

    NASA Technical Reports Server (NTRS)

    Mcclain, C. R.

    1979-01-01

    A nonrecursive numerical filter is described in which the weighting sequence is optimized by minimizing the excursion from the ideal rectangular filter in a least squares sense over the entire domain of normalized frequency. Additional corrections to the weights in order to reduce overshoot oscillations (Gibbs phenomenon) and to insure unity gain at zero frequency for the low pass filter are incorporated. The filter is characterized by a zero phase shift for all frequencies (due to a symmetric weighting sequence), a finite memory and stability, and it may readily be transformed to a high pass filter. Equations for the filter weights and the frequency response function are presented, and applications to high and low pass filtering are examined. A discussion of optimization of high pass filter parameters for a rather stringent response requirement is given in an application to the removal of aircraft low frequency oscillations superimposed on remotely sensed ocean surface profiles. Several frequency response functions are displayed, both in normalized frequency space and in period space. A comparison of the performance of the Martin filter with some other commonly used low pass digital filters is provided in an application to oceanographic data.

  15. Tomography and Purification of the Temporal-Mode Structure of Quantum Light

    NASA Astrophysics Data System (ADS)

    Ansari, Vahid; Donohue, John M.; Allgaier, Markus; Sansoni, Linda; Brecht, Benjamin; Roslund, Jonathan; Treps, Nicolas; Harder, Georg; Silberhorn, Christine

    2018-05-01

    High-dimensional quantum information processing promises capabilities beyond the current state of the art, but addressing individual information-carrying modes presents a significant experimental challenge. Here we demonstrate effective high-dimensional operations in the time-frequency domain of nonclassical light. We generate heralded photons with tailored temporal-mode structures through the pulse shaping of a broadband parametric down-conversion pump. We then implement a quantum pulse gate, enabled by dispersion-engineered sum-frequency generation, to project onto programmable temporal modes, reconstructing the quantum state in seven dimensions. We also manipulate the time-frequency structure by selectively removing temporal modes, explicitly demonstrating the effectiveness of engineered nonlinear processes for the mode-selective manipulation of quantum states.

  16. Spatial Frequency Requirements and Gaze Strategy in Visual-Only and Audiovisual Speech Perception

    PubMed Central

    Wilson, Amanda H.; Paré, Martin; Munhall, Kevin G.

    2016-01-01

    Purpose The aim of this article is to examine the effects of visual image degradation on performance and gaze behavior in audiovisual and visual-only speech perception tasks. Method We presented vowel–consonant–vowel utterances visually filtered at a range of frequencies in visual-only, audiovisual congruent, and audiovisual incongruent conditions (Experiment 1; N = 66). In Experiment 2 (N = 20), participants performed a visual-only speech perception task and in Experiment 3 (N = 20) an audiovisual task while having their gaze behavior monitored using eye-tracking equipment. Results In the visual-only condition, increasing image resolution led to monotonic increases in performance, and proficient speechreaders were more affected by the removal of high spatial information than were poor speechreaders. The McGurk effect also increased with increasing visual resolution, although it was less affected by the removal of high-frequency information. Observers tended to fixate on the mouth more in visual-only perception, but gaze toward the mouth did not correlate with accuracy of silent speechreading or the magnitude of the McGurk effect. Conclusions The results suggest that individual differences in silent speechreading and the McGurk effect are not related. This conclusion is supported by differential influences of high-resolution visual information on the 2 tasks and differences in the pattern of gaze. PMID:27537379

  17. Signal Frequency Spectra with Audacity®

    ERIC Educational Resources Information Center

    Gailey, Alycia

    2015-01-01

    The primary objective of the activity presented here is to allow students to explore the frequency components of various simple signals, with the ultimate goal of teaching them how to remove unwanted noise from a voice signal. Analysis of the frequency components of a signal allows students to design filters that remove unwanted components of a…

  18. Impact of image quality on OCT angiography based quantitative measurements.

    PubMed

    Al-Sheikh, Mayss; Ghasemi Falavarjani, Khalil; Akil, Handan; Sadda, SriniVas R

    2017-01-01

    To study the impact of image quality on quantitative measurements and the frequency of segmentation error with optical coherence tomography angiography (OCTA). Seventeen eyes of 10 healthy individuals were included in this study. OCTA was performed using a swept-source device (Triton, Topcon). Each subject underwent three scanning sessions 1-2 min apart; the first two scans were obtained under standard conditions and for the third session, the image quality index was reduced using application of a topical ointment. En face OCTA images of the retinal vasculature were generated using the default segmentation for the superficial and deep retinal layer (SRL, DRL). Intraclass correlation coefficient (ICC) was used as a measure for repeatability. The frequency of segmentation error, motion artifact, banding artifact and projection artifact was also compared among the three sessions. The frequency of segmentation error, and motion artifact was statistically similar between high and low image quality sessions (P = 0.707, and P = 1 respectively). However, the frequency of projection and banding artifact was higher with a lower image quality. The vessel density in the SRL was highly repeatable in the high image quality sessions (ICC = 0.8), however, the repeatability was low, comparing the high and low image quality measurements (ICC = 0.3). In the DRL, the repeatability of the vessel density measurements was fair in the high quality sessions (ICC = 0.6 and ICC = 0.5, with and without automatic artifact removal, respectively) and poor comparing high and low image quality sessions (ICC = 0.3 and ICC = 0.06, with and without automatic artifact removal, respectively). The frequency of artifacts is higher and the repeatability of the measurements is lower with lower image quality. The impact of image quality index should be always considered in OCTA based quantitative measurements.

  19. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    PubMed

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. High-speed ultraviolet photometry of HD 60435

    NASA Technical Reports Server (NTRS)

    Taylor, M.; Nelson, M. J.; Bless, R. C.; Dolan, J. F.; Elliot, J. L.; Percival, J. W.; Robinson, E. L.; Van Citters, G. W.

    1993-01-01

    We present the first high-speed ultraviolet photometry of an oscillating Ap star, HD 60435. After removing known orbital effects related to the Hubble Space Telescope, we confirm the presence of a strong pulsation period at a frequency of 123.70 cycles per day. In addition, we find significant amplitude modulation of this frequency that we suggest could be the result of beating of multiple periodicities. In this context, we suggest evidence for the presence of four additional frequencies at nu = 120.56, 126.55, 149.49, and 221.03 cycles per day. Three of these frequencies correspond well to frequencies detected in optical observations of HD 60435. The fourth, at 149.49 cycles per day, if real, is a potentially new pulsation mode that has not been detected in ground-based observations of this star. The amplitude of the 123 cycles per day pulsation is significantly larger in the ultraviolet than it is in the blue.

  1. Automatic single-image-based rain streaks removal via image decomposition.

    PubMed

    Kang, Li-Wei; Lin, Chia-Wen; Fu, Yu-Hsiang

    2012-04-01

    Rain removal from a video is a challenging problem and has been recently investigated extensively. Nevertheless, the problem of rain removal from a single image was rarely studied in the literature, where no temporal information among successive images can be exploited, making the problem very challenging. In this paper, we propose a single-image-based rain removal framework via properly formulating rain removal as an image decomposition problem based on morphological component analysis. Instead of directly applying a conventional image decomposition technique, the proposed method first decomposes an image into the low- and high-frequency (HF) parts using a bilateral filter. The HF part is then decomposed into a "rain component" and a "nonrain component" by performing dictionary learning and sparse coding. As a result, the rain component can be successfully removed from the image while preserving most original image details. Experimental results demonstrate the efficacy of the proposed algorithm.

  2. Effect of Physicochemical Properties of Slag and Flux on the Removal Rate of Oxide Inclusion from Molten Steel

    NASA Astrophysics Data System (ADS)

    Park, Jun Seok; Park, Joo Hyun

    2016-12-01

    The slag-metal reaction experiments were carried out using a high-frequency induction furnace to confirm the effect of slag composition on the removal rate of inclusions in molten steel through the CaO-based slags. The apparent rate constant of oxygen removal ( k O) was obtained as a function of slag composition. It increased with increasing basicity, and the content of MgO and CaF2, whereas it decreased by increasing the content of Al2O3 in the slag. The removal rate of inclusions was strongly affected not only by the driving force of the chemical dissolution but also by the viscosity of the slags and fluxes.

  3. On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP.

    PubMed

    Winkler, Irene; Debener, Stefan; Müller, Klaus-Robert; Tangermann, Michael

    2015-01-01

    Standard artifact removal methods for electroencephalographic (EEG) signals are either based on Independent Component Analysis (ICA) or they regress out ocular activity measured at electrooculogram (EOG) channels. Successful ICA-based artifact reduction relies on suitable pre-processing. Here we systematically evaluate the effects of high-pass filtering at different frequencies. Offline analyses were based on event-related potential data from 21 participants performing a standard auditory oddball task and an automatic artifactual component classifier method (MARA). As a pre-processing step for ICA, high-pass filtering between 1-2 Hz consistently produced good results in terms of signal-to-noise ratio (SNR), single-trial classification accuracy and the percentage of `near-dipolar' ICA components. Relative to no artifact reduction, ICA-based artifact removal significantly improved SNR and classification accuracy. This was not the case for a regression-based approach to remove EOG artifacts.

  4. Mechanistic modeling of destratification in cryogenic storage tanks using ultrasonics.

    PubMed

    Jagannathan, T K; Mohanan, Srijith; Nagarajan, R

    2014-01-01

    Stratification is one of the main causes for vaporization of cryogens and increase of tank pressure during cryogenic storage. This leads subsequent problems such as cavitation in cryo-pumps, reduced length of storage time. Hence, it is vital to prevent stratification to improve the cost efficiency of storage systems. If stratified layers exist inside the tank, they have to be removed by suitable methods without venting the vapor. Sonication is one such method capable of keeping fluid layers mixed. In the present work, a mechanistic model for ultrasonic destratification is proposed and validated with destratification experiments done in water. Then, the same model is used to predict the destratification characteristics of cryogenic liquids such as liquid nitrogen (LN₂), liquid hydrogen (LH₂) and liquid ammonia (LNH₃). The destratification parameters are analysed for different frequencies of ultrasound and storage pressures by considering continuous and pulsed modes of ultrasonic operation. From the results, it is determined that use of high frequency ultrasound (low-power/continuous; high-power/pulsing) or low frequency ultrasound (continuous operation with moderate power) can both be effective in removing stratification. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Removing function model and experiments on ultrasonic polishing molding die

    NASA Astrophysics Data System (ADS)

    Huang, Qitai; Ni, Ying; Yu, Jingchi

    2010-10-01

    Low temperature glass molding technology is the main method on volume-producing high precision middle and small diameter optical cells in the future. While the accuracy of the molding die will effect the cell precision, so the high precision molding die development is one of the most important part of the low temperature glass molding technology. The molding die is manufactured from high rigid and crisp metal alloy, with the ultrasonic vibration character of high vibration frequency and concentrative energy distribution; abrasive particles will impact the rigid metal alloy surface with very high speed that will remove the material from the work piece. Ultrasonic can make the rigid metal alloy molding die controllable polishing and reduce the roughness and surface error. Different from other ultrasonic fabrication method, untouched ultrasonic polishing is applied on polish the molding die, that means the tool does not touch the work piece in the process of polishing. The abrasive particles vibrate around the balance position with high speed and frequency under the drive of ultrasonic vibration in the liquid medium and impact the workspace surface, the energy of abrasive particles come from ultrasonic vibration, while not from the direct hammer blow of the tool. So a nummular vibrator simple harmonic vibrates on an infinity plane surface is considered as a model of ultrasonic polishing working condition. According to Huygens theory the sound field distribution on a plane surface is analyzed and calculated, the tool removing function is also deduced from this distribution. Then the simple point ultrasonic polishing experiment is proceeded to certificate the theory validity.

  6. SAFL Baffle retrofit for suspended sediment removal in storm sewer sumps.

    PubMed

    Howard, Adam; Mohseni, Omid; Gulliver, John; Stefan, Heinz

    2011-11-15

    Standard sumps (manholes) provide a location for pipe junctions and maintenance access in stormwater drainage systems. Standard sumps can also remove sand and silt particles from stormwater, but have a high propensity for washout of the collected sediment. With appropriate maintenance these sumps may qualify as a stormwater best management practice (BMP) device for the removal of suspended sediment from stormwater runoff. To decrease the maintenance frequency and prevent standard sumps from becoming a source of suspended sediment under high flow conditions, a porous baffle, named the SAFL Baffle, has been designed and tested as a retrofit to the sump. Multiple configurations with varying percent open area and different angles of attack were evaluated in scale models. An optimum configuration was then constructed at the prototype scale and evaluated for both removal efficiency and washout. Results obtained with the retrofit indicate that with the right baffle dimensions and porosity, sediment washout from the sump at high flow rates can be almost eliminated, and removal efficiency can be significantly increased at low flow rates. Removal efficiency and washout functions have been developed for standard sumps retrofitted with the SAFL Baffle. The results of this research provide a new, versatile stormwater treatment device and implemented new washout and removal efficiency testing procedures that will improve research and development of stormwater treatment devices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Study on regeneration effect and mechanism of high-frequency ultrasound on biological activated carbon.

    PubMed

    Sun, Zhehao; Liu, Cheng; Cao, Zhen; Chen, Wei

    2018-06-01

    High frequency ultrasonic radiation technology was developed as a novel and efficient means of regenerating spent biological activated carbon (BAC) used in drinking water treatment plants (DWTPs). The results of this study indicated that high frequency ultrasonic treatment could recover the spent BAC, to some extent, with the following optimal conditions: a frequency of 400 kHz, sonication power of 60 W, water temperature of 30 °C, and sonication time of 6 min. Under the above conditions, the iodine value increased from 300 mg/g to 409 mg/g, the volume of total pores and micropores increased from 0.2600 cm 3 /g and 0.1779 cm 3 /g to 0.3560 cm 3 /g and 0.2662 cm 3 /g, respectively; the specific surface area of micropores and the mean pore diameter expanded from 361.15 m 2 /g and 2.0975 nm to 449.92 m 2 /g and 2.1268 nm, respectively. The biological activity increased from 0.0297 mgO 2 /gC·h to 0.0521 mgO 2 /gC·h, while the biomass decreased from 203 nmolP/gC to 180 nmolP/gC. The results of high throughput 16S rRNA gene amplicon sequencing showed that microorganisms such as Clostridia and Nitrospira were markedly decreased due to high frequency ultrasound. The method used in this study caused the inhibition of certain carbon-attached microbials resulting in a negative effect on the removal rate of ammonia-N during the initial stage of the long-term reuse operation. The removal of UV254 and atrazine were restored from 8.1% and 55% to 21% and 76%, respectively. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Detecting and Treating Thyroid Nodules and Cancer Before, During, and After Pregnancy

    MedlinePlus

    ... nodules relies mainly on the results of thyroid ultrasound imaging and fine-needle aspiration biopsy . A biopsy is the removal of a small sample of the nodule for further testing. Thyroid ultrasound uses the same safe technique of high- frequency ...

  9. Auditory steady-state responses in cochlear implant users: Effect of modulation frequency and stimulation artifacts.

    PubMed

    Gransier, Robin; Deprez, Hanne; Hofmann, Michael; Moonen, Marc; van Wieringen, Astrid; Wouters, Jan

    2016-05-01

    Previous studies have shown that objective measures based on stimulation with low-rate pulse trains fail to predict the threshold levels of cochlear implant (CI) users for high-rate pulse trains, as used in clinical devices. Electrically evoked auditory steady-state responses (EASSRs) can be elicited by modulated high-rate pulse trains, and can potentially be used to objectively determine threshold levels of CI users. The responsiveness of the auditory pathway of profoundly hearing-impaired CI users to modulation frequencies is, however, not known. In the present study we investigated the responsiveness of the auditory pathway of CI users to a monopolar 500 pulses per second (pps) pulse train modulated between 1 and 100 Hz. EASSRs to forty-three modulation frequencies, elicited at the subject's maximum comfort level, were recorded by means of electroencephalography. Stimulation artifacts were removed by a linear interpolation between a pre- and post-stimulus sample (i.e., blanking). The phase delay across modulation frequencies was used to differentiate between the neural response and a possible residual stimulation artifact after blanking. Stimulation artifacts were longer than the inter-pulse interval of the 500pps pulse train for recording electrodes ipsilateral to the CI. As a result the stimulation artifacts could not be removed by artifact removal on the bases of linear interpolation for recording electrodes ipsilateral to the CI. However, artifact-free responses could be obtained in all subjects from recording electrodes contralateral to the CI, when subject specific reference electrodes (Cz or Fpz) were used. EASSRs to modulation frequencies within the 30-50 Hz range resulted in significant responses in all subjects. Only a small number of significant responses could be obtained, during a measurement period of 5 min, that originate from the brain stem (i.e., modulation frequencies in the 80-100 Hz range). This reduced synchronized activity of brain stem responses in long-term severely-hearing impaired CI users could be an attribute of processes associated with long-term hearing impairment and/or electrical stimulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Evaluation the anaerobic hydrolysis acidification stage of kitchen waste by pH regulation.

    PubMed

    Wang, Yaya; Zang, Bing; Li, Guoxue; Liu, Yu

    2016-07-01

    This study analyzed the composition and characteristic of kitchen waste (KW) from closed cleaning station of Chaoyang District, Beijing. It was featured by high vegetables and peels contents. This study investigated effect of pH regulation and uncontrolled pH (CK) on the lab-scale anaerobic hydrolysis acidification stage of KW. The optimal adjusting mode by NaOH (including dosage and frequency) was evaluated according to indexes of pH, VFAs, NH4(+)-N, TS, VS, TS/VS, TS and VS removal rate. The treatment 4 as first two days adjusting per 16h and then one time per day at pH 7 was chosen as the optimal mode with high VFAs content(47.31g/L), TS and VS removal rate (42.95% and 54.01%, respectively), low adjusting frequency, fewer dosage and practical operability. Thus, adjusting mode of treatment 4 could be considered using in anaerobic hydrolysis acidification stage on engineering. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Choledochoscopic high-frequency needle-knife electrotomy for treatment of anastomotic strictures after Roux-en-Y hepaticojejunostomy.

    PubMed

    Yang, Yu-Long; Zhang, Cheng; Wu, Ping; Ma, Yue-Feng; Li, Jing-Yi; Zhang, Hong-Wei; Shi, Li-Jun; Lin, Mei-Ju; Yu, Ying

    2016-05-06

    Anastomotic stricture is a complex and substantial complication following Roux-en-Y hepaticojejunostomy. Initially, endoscopic and percutaneous approaches are often attempted, but the gold standard remains surgical biliary reconstruction, especially for refractory stricture. However, this solution leaves much room for improvement, due to the challenging nature of the biliary reconstruction procedure, in which anastomotic stricture may still occur. To investigate the feasibility and effectiveness of choledochoscopic high-frequency needle-knife electrotomy as an intervention in the treatment of anastomotic strictures following Roux-en-Y hepaticojejunostomy. From February 2010 to October 2014, clinical data was collected and retrospectively compared for patients who underwent balloon dilation or/and choledochoscopic high-frequency needle-knife electrotomy for the treatment of anastomotic strictures after Roux-en-Y hepaticojejunostomy. A total of 38 patients underwent successful choledochoscopic treatment and all the anastomotic strictures were removed successfully, 19 of which were treated with electrotomy, 7 with balloon dilation, and 12 with both electrotomy and balloon dilation. Among these groups,the average operating times were 6.9 ± 2.4 min,10.1 ± 6.8 min, and 20.2 ± 13.5 min, respectively. The average stent supporting times were 6.3 ± 0.7 months, 6.5 ± 0.6 months, and 6.1 ± 0.4 respectively. The mean follow-up after stent removal was 42.1 ± 27.4 months, and in 26.3 % (5/19), 28.5 % (2/7) and 16.7 % (2/12) of cases, recurrent anastomotic stricture occurred. Of these 9 total patients with recurrent anastomotic, two patients were successfully rescued by full-covered self-expanding removable metal stents and 7 patients by electrotomy combined with balloon dilation. Choledochoscopic high-frequency needle-knife electrotomy is both feasible and safe in the treatment of anastomotic stricture after Roux-en-Y hepaticojejunostomy, with a similar long-term outcome to balloon dilation in treating anastomotic stricture after Roux-en-Y hepaticojejunostomy. A combination of choledochoscopic electrotomy concurrent with balloon dilation should be recommended based on the low rate of recurrence.

  12. Highly Omnidirectional and Frequency Controllable Carbon/Polyaniline-based 2D and 3D Monopole Antenna

    NASA Astrophysics Data System (ADS)

    Shin, Keun-Young; Kim, Minkyu; Lee, James S.; Jang, Jyongsik

    2015-09-01

    Highly omnidirectional and frequency controllable carbon/polyaniline (C/PANI)-based, two- (2D) and three-dimensional (3D) monopole antennas were fabricated using screen-printing and a one-step, dimensionally confined hydrothermal strategy, respectively. Solvated C/PANI was synthesized by low-temperature interfacial polymerization, during which strong π-π interactions between graphene and the quinoid rings of PANI resulted in an expanded PANI conformation with enhanced crystallinity and improved mechanical and electrical properties. Compared to antennas composed of pristine carbon or PANI-based 2D monopole structures, 2D monopole antennas composed of this enhanced hybrid material were highly efficient and amenable to high-frequency, omnidirectional electromagnetic waves. The mean frequency of C/PANI fiber-based 3D monopole antennas could be controlled by simply cutting and stretching the antenna. These antennas attained high peak gain (3.60 dBi), high directivity (3.91 dBi) and radiation efficiency (92.12%) relative to 2D monopole antenna. These improvements were attributed the high packing density and aspect ratios of C/PANI fibers and the removal of the flexible substrate. This approach offers a valuable and promising tool for producing highly omnidirectional and frequency-controllable, carbon-based monopole antennas for use in wireless networking communications on industrial, scientific, and medical (ISM) bands.

  13. Highly Omnidirectional and Frequency Controllable Carbon/Polyaniline-based 2D and 3D Monopole Antenna

    PubMed Central

    Shin, Keun-Young; Kim, Minkyu; Lee, James S.; Jang, Jyongsik

    2015-01-01

    Highly omnidirectional and frequency controllable carbon/polyaniline (C/PANI)-based, two- (2D) and three-dimensional (3D) monopole antennas were fabricated using screen-printing and a one-step, dimensionally confined hydrothermal strategy, respectively. Solvated C/PANI was synthesized by low-temperature interfacial polymerization, during which strong π–π interactions between graphene and the quinoid rings of PANI resulted in an expanded PANI conformation with enhanced crystallinity and improved mechanical and electrical properties. Compared to antennas composed of pristine carbon or PANI-based 2D monopole structures, 2D monopole antennas composed of this enhanced hybrid material were highly efficient and amenable to high-frequency, omnidirectional electromagnetic waves. The mean frequency of C/PANI fiber-based 3D monopole antennas could be controlled by simply cutting and stretching the antenna. These antennas attained high peak gain (3.60 dBi), high directivity (3.91 dBi) and radiation efficiency (92.12%) relative to 2D monopole antenna. These improvements were attributed the high packing density and aspect ratios of C/PANI fibers and the removal of the flexible substrate. This approach offers a valuable and promising tool for producing highly omnidirectional and frequency-controllable, carbon-based monopole antennas for use in wireless networking communications on industrial, scientific, and medical (ISM) bands. PMID:26338090

  14. Intrapulpal temperatures during pulsed Nd:YAG laser treatment of dentin, in vitro.

    PubMed

    White, J M; Fagan, M C; Goodis, H E

    1994-03-01

    Lasers are being used for soft tissue removal, caries removal, and treatment of root surface sensitivity. One concern for laser safety is that the heat produced at the irradiated root surface may diffuse to the pulp causing irreversible pulpal damage. To test this heat diffusion, copper-constantan thermocouples were inserted into the radicular pulp canals of extracted teeth. Simulating direct exposure which might occur during gingival excision, superficial caries removal, and modification of the dentin surface for treatment of root surface sensitivity, a 2 mm2 area of the external root surface was uniformly irradiated with a pulsed Nd:YAG laser using a 320 microns diameter fiber optic contact probe. Power was varied from 0.3 to 3.0 W with frequencies of 10 and 20 Hz. Temperature changes during cavity preparations using a high speed handpiece with air coolant were also recorded. Repeated measures ANOVA (P < or = 0.05) indicated that intrapulpal temperatures increased as a function of power, frequency, and time. Intrapulpal temperatures decreased as remaining dentin thickness (0.2 to 2.0 mm) increased for each laser parameter. Irradiation of dentin using a Nd:YAG pulsed laser, within the treatment times, powers, and frequencies with adequate remaining dentin thickness, as outlined in this paper, should not cause devitalizing intrapulpal temperature rises.

  15. High frequency measurements of reach scale nitrogen uptake in a fourth order river with contrasting hydromorphology and variable water chemistry (Weiße Elster, Germany)

    NASA Astrophysics Data System (ADS)

    Kunz, Julia Vanessa; Hensley, Robert; Brase, Lisa; Borchardt, Dietrich; Rode, Michael

    2017-01-01

    River networks exhibit a globally important capacity to retain and process nitrogen. However direct measurement of in-stream removal in higher order streams and rivers has been extremely limited. The recent advent of automated sensors has allowed high frequency measurements, and the development of new passive methods of quantifying nitrogen uptake which are scalable across river size. Here we extend these methods to higher order streams with anthropogenically elevated nitrogen levels, substantial tributaries, complex input signals, and multiple N species. We use a combination of two station time-series and longitudinal profiling of nitrate to assess differences in nitrogen processing dynamics in a natural versus a channelized impounded reach with WWTP effluent impacted water chemistry. Our results suggest that net mass removal rates of nitrate were markedly higher in the unmodified reach. Additionally, seasonal variations in temperature and insolation affected the relative contribution of assimilatory versus dissimilatory uptake processes, with the latter exhibiting a stronger positive dependence on temperature. From a methodological perspective, we demonstrate that a mass balance approach based on high frequency data can be useful in deriving quantitative uptake estimates, even under dynamic inputs and lateral tributary inflow. However, uncertainty in diffuse groundwater inputs and more importantly the effects of alternative nitrogen species, in this case ammonium, pose considerable challenges to this method.

  16. Reference-Free Removal of EEG-fMRI Ballistocardiogram Artifacts with Harmonic Regression

    PubMed Central

    Krishnaswamy, Pavitra; Bonmassar, Giorgio; Poulsen, Catherine; Pierce, Eric T; Purdon, Patrick L.; Brown, Emery N.

    2016-01-01

    Combining electroencephalogram (EEG) recording and functional magnetic resonance imaging (fMRI) offers the potential for imaging brain activity with high spatial and temporal resolution. This potential remains limited by the significant ballistocardiogram (BCG) artifacts induced in the EEG by cardiac pulsation-related head movement within the magnetic field. We model the BCG artifact using a harmonic basis, pose the artifact removal problem as a local harmonic regression analysis, and develop an efficient maximum likelihood algorithm to estimate and remove BCG artifacts. Our analysis paradigm accounts for time-frequency overlap between the BCG artifacts and neurophysiologic EEG signals, and tracks the spatiotemporal variations in both the artifact and the signal. We evaluate performance on: simulated oscillatory and evoked responses constructed with realistic artifacts; actual anesthesia-induced oscillatory recordings; and actual visual evoked potential recordings. In each case, the local harmonic regression analysis effectively removes the BCG artifacts, and recovers the neurophysiologic EEG signals. We further show that our algorithm outperforms commonly used reference-based and component analysis techniques, particularly in low SNR conditions, the presence of significant time-frequency overlap between the artifact and the signal, and/or large spatiotemporal variations in the BCG. Because our algorithm does not require reference signals and has low computational complexity, it offers a practical tool for removing BCG artifacts from EEG data recorded in combination with fMRI. PMID:26151100

  17. Spectral components in electromyograms from four regions of the human masseter, in natural dentate and edentulous subjects with removable prostheses and implants.

    PubMed

    Guzmán-Venegas, Rodrigo A; Palma, Felipe H; Biotti P, Jorge L; de la Rosa, Francisco J Berral

    2018-06-01

    To compare the frequency or spectral components between different regions of the superficial masseter in young natural dentate and total edentulous older adults rehabilitated with removable prostheses and fixed-implant support. A secondary objective was to compare these components between the three groups. 21 young natural dentate and 28 edentulous (14 with removable prostheses and 14 with fixed-implant support) were assessed. High-density surface electromyography (sEMG) was recorded in four portions of the superficial masseter during submaximal isometric bites. Spectral components were obtained through a spectral analysis of the sEMG signals. An analysis of mixed models was used to compare the spectral components. In all groups, the spectral components of the anterior portion were lower than in the posterior region (p < 0.05). Both edentulous groups showed lower spectral components and median frequency slope than the natural dentate group (p < 0.05). The removable prostheses group showed the greatest differences with natural dentate group. There were significant differences in the spectral components recorded in the different regions of the superficial masseter. The lower spectral components and fatigability of older adults rehabilitated with prostheses could be a cause of a greater loss of type II fibers, especially in the removable prostheses group. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Digital Filtering of Three-Dimensional Lower Extremity Kinematics: an Assessment

    PubMed Central

    Sinclair, Jonathan; Taylor, Paul John; Hobbs, Sarah Jane

    2013-01-01

    Errors in kinematic data are referred to as noise and are an undesirable portion of any waveform. Noise is typically removed using a low-pass filter which removes the high frequency components of the signal. The selection of an optimal frequency cut-off is very important when processing kinematic information and a number of techniques exists for the determination of an optimal frequency cut-off. Despite the importance of cut-off frequency to the efficacy of kinematic analyses there is currently a paucity of research examining the influence of different cut-off frequencies on the resultant 3-D kinematic waveforms and discrete parameters. Twenty participants ran at 4.0 m•s−1 as lower extremity kinematics in the sagittal, coronal and transverse planes were measured using an eight camera motion analysis system. The data were filtered at a range of cut-off frequencies and the discrete kinematic parameters were examined using repeated measures ANOVA’s. The similarity between the raw and filtered waveforms were examined using intra-class correlations. The results show that the cut-off frequency has a significant influence on the discrete kinematic measure across displacement and derivative information in all three planes of rotation. Furthermore, it was also revealed that as the cut-off frequency decreased the attenuation of the kinematic waveforms became more pronounced, particularly in the coronal and transverse planes at the second derivative. In conclusion, this investigation provides new information regarding the influence of digital filtering on lower extremity kinematics and re-emphasizes the importance of selecting the correct cut-off frequency. PMID:24511338

  19. Hardware Implementation of 32-Bit High-Speed Direct Digital Frequency Synthesizer

    PubMed Central

    Ibrahim, Salah Hasan; Ali, Sawal Hamid Md.; Islam, Md. Shabiul

    2014-01-01

    The design and implementation of a high-speed direct digital frequency synthesizer are presented. A modified Brent-Kung parallel adder is combined with pipelining technique to improve the speed of the system. A gated clock technique is proposed to reduce the number of registers in the phase accumulator design. The quarter wave symmetry technique is used to store only one quarter of the sine wave. The ROM lookup table (LUT) is partitioned into three 4-bit sub-ROMs based on angular decomposition technique and trigonometric identity. Exploiting the advantages of sine-cosine symmetrical attributes together with XOR logic gates, one sub-ROM block can be removed from the design. These techniques, compressed the ROM into 368 bits. The ROM compressed ratio is 534.2 : 1, with only two adders, two multipliers, and XOR-gates with high frequency resolution of 0.029 Hz. These techniques make the direct digital frequency synthesizer an attractive candidate for wireless communication applications. PMID:24991635

  20. A new polishing process for large-aperture and high-precision aspheric surface

    NASA Astrophysics Data System (ADS)

    Nie, Xuqing; Li, Shengyi; Dai, Yifan; Song, Ci

    2013-07-01

    The high-precision aspheric surface is hard to be achieved due to the mid-spatial frequency error in the finishing step. The influence of mid-spatial frequency error is studied through the simulations and experiments. In this paper, a new polishing process based on magnetorheological finishing (MRF), smooth polishing (SP) and ion beam figuring (IBF) is proposed. A 400mm aperture parabolic surface is polished with this new process. The smooth polishing (SP) is applied after rough machining to control the MSF error. In the middle finishing step, most of low-spatial frequency error is removed by MRF rapidly, then the mid-spatial frequency error is restricted by SP, finally ion beam figuring is used to finish the surface. The surface accuracy is improved from the initial 37.691nm (rms, 95% aperture) to the final 4.195nm. The results show that the new polishing process is effective to manufacture large-aperture and high-precision aspheric surface.

  1. Wastewater microalgal production, nutrient removal and physiological adaptation in response to changes in mixing frequency.

    PubMed

    Sutherland, Donna L; Turnbull, Matthew H; Broady, Paul A; Craggs, Rupert J

    2014-09-15

    Laminar flows are a common problem in high rate algal ponds (HRAP) due to their long channels and gentle mixing by a single paddlewheel. Sustained laminar flows may modify the amount of light microalgal cells are exposed to, increase the boundary layer between the cell and the environment and increase settling out of cells onto the pond bottom. To date, there has been little focus on the effects of the time between mixing events (frequency of mixing) on the performance of microalgae in wastewater treatment HRAPs. This paper investigates the performance of three morphologically distinct microalgae in wastewater treatment high rate algal mesocosms operated at four different mixing frequencies (continuous, mixed every 45 min, mixed every 90 min and no mixing). Microalgal performance was measured in terms of biomass concentration, nutrient removal efficiency, light utilisation and photosynthetic performance. Microalgal biomass increased significantly with increasing mixing frequency for the two colonial species but did not differ for the single celled species. All three species were more efficient at NH4-N uptake as the frequency of mixing increased. Increased frequency of mixing supported larger colonies with improved harvest-ability by gravity but at the expense of efficient light absorption and maximum rate of photosynthesis. However, maximum quantum yield was highest in the continuously mixed cultures due to higher efficiency of photosynthesis under light limited conditions. Based on these results, higher microalgal productivity, improved wastewater treatment and better gravity based harvest-ability can be achieved with the inclusion of more mixing points and reduced laminar flows in full-scale HRAP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Frequency-doubled Alexandrite laser for use in periodontology: a scanning electron microscopic investigation

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas

    1996-12-01

    During prior studies it could be demonstrated that engaging a frequency double Alexandrite-laser allows a fast and strictly selective ablation of supra- and subgingival calculus. Furthermore, the removal of unstained microbial plaque was observed. First conclusions were drawn following light microscopic investigations on undecalcified sections of irradiated teeth. In the present study the cementum surface after irradiation with a frequency doubled Alexandrite-laser was observed by means of a scanning electron microscope. After irradiation sections of teeth were dried in alcohol and sputtered with gold. In comparison irradiated cementum surfaces of unerupted operatively removed wisdom teeth and tooth surfaces after the selective removal of calculus were investigated. A complete removal of calculus was observed as well as a remaining smooth surface of irradiated cementum.

  3. Digital image enhancement techniques used in some ERTS application problems. [geology, geomorphology, and oceanography

    NASA Technical Reports Server (NTRS)

    Goetz, A. F. H.; Billingsley, F. C.

    1974-01-01

    Enhancements discussed include contrast stretching, multiratio color displays, Fourier plane operations to remove striping and boosting MTF response to enhance high spatial frequency content. The use of each technique in a specific application in the fields of geology, geomorphology and oceanography is demonstrated.

  4. Electrical Behavior of Copper Mine Tailings During EKR with Modified Electric Fields.

    PubMed

    Rojo, Adrian; Hansen, Henrik K; Monárdez, Omara; Jorquera, Carlos; Santis, Paulina; Inostroza, Paula

    2017-03-01

    Electro-kinetic remediation (EKR) with sinusoidal electric field obtained simultaneously with DC/AC voltage reduce the polarization of the EKR with DC voltage. The DC voltage value defines the presence of a periodic polarity reversal of the cell and the electrical charge for electro-kinetic transport. In this case, the AC frequency favors the breaking of polarization conditions resulting from the EKR with DC voltage. However, with high frequencies a negative effect occurs where the tailings behave as a filter circuit, discriminating frequencies of an electric signal. The goal of this work is to analyse the electrical behaviour of tailings in EKR experiments. The conditions selected were: DC/AC voltages: 10/15 and 20/25 V (peak values), and AC voltage frequencies 50-2000 Hz. When the AC frequency reaches 2000 Hz, the copper removal tends to zero, indicating that the tailing behaves as a high-pass filter in which the DC voltage was filtered out.

  5. Spatial resolution of a hard x-ray CCD detector.

    PubMed

    Seely, John F; Pereira, Nino R; Weber, Bruce V; Schumer, Joseph W; Apruzese, John P; Hudson, Lawrence T; Szabo, Csilla I; Boyer, Craig N; Skirlo, Scott

    2010-08-10

    The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70 keV energy range. The detector had 20 microm pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer's Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95 microm (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.

  6. Path planning and parameter optimization of uniform removal in active feed polishing

    NASA Astrophysics Data System (ADS)

    Liu, Jian; Wang, Shaozhi; Zhang, Chunlei; Zhang, Linghua; Chen, Huanan

    2015-06-01

    A high-quality ultrasmooth surface is demanded in short-wave optical systems. However, the existing polishing methods have difficulties meeting the requirement on spherical or aspheric surfaces. As a new kind of small tool polishing method, active feed polishing (AFP) could attain a surface roughness of less than 0.3 nm (RMS) on spherical elements, although AFP may magnify the residual figure error or mid-frequency error. The purpose of this work is to propose an effective algorithm to realize uniform removal of the surface in the processing. At first, the principle of the AFP and the mechanism of the polishing machine are introduced. In order to maintain the processed figure error, a variable pitch spiral path planning algorithm and the dwell time-solving model are proposed. For suppressing the possible mid-frequency error, the uniformity of the synthesis tool path, which is generated by an arbitrary point at the polishing tool bottom, is analyzed and evaluated, and the angular velocity ratio of the tool spinning motion to the revolution motion is optimized. Finally, an experiment is conducted on a convex spherical surface and an ultrasmooth surface is finally acquired. In conclusion, a high-quality ultrasmooth surface can be successfully obtained with little degradation of the figure and mid-frequency errors by the algorithm.

  7. Frequency analysis of a step dynamic pressure calibrator.

    PubMed

    Choi, In-Mook; Yang, Inseok; Yang, Tae-Heon

    2012-09-01

    A dynamic high pressure standard is becoming more essential in the fields of mobile engines, space science, and especially the area of defense such as long-range missile development. However, a complication arises when a dynamic high pressure sensor is compared with a reference dynamic pressure gauge calibrated in static mode. Also, it is difficult to determine a reference dynamic pressure signal from the calibrator because a dynamic high pressure calibrator generates unnecessary oscillations in a positive-going pressure step method. A dynamic high pressure calibrator, using a quick-opening ball valve, generates a fast step pressure change within 1 ms; however, the calibrator also generates a big impulse force that can lead to a short life-time of the system and to oscillating characteristics in response to the dynamic sensor to be calibrated. In this paper, unnecessary additional resonant frequencies besides those of the step function are characterized using frequency analysis. Accordingly, the main sources of resonance are described. In order to remove unnecessary frequencies, the post processing results, obtained by a filter, are given; also, a method for the modification of the dynamic calibration system is proposed.

  8. Frequency analysis of a step dynamic pressure calibrator

    NASA Astrophysics Data System (ADS)

    Choi, In-Mook; Yang, Inseok; Yang, Tae-Heon

    2012-09-01

    A dynamic high pressure standard is becoming more essential in the fields of mobile engines, space science, and especially the area of defense such as long-range missile development. However, a complication arises when a dynamic high pressure sensor is compared with a reference dynamic pressure gauge calibrated in static mode. Also, it is difficult to determine a reference dynamic pressure signal from the calibrator because a dynamic high pressure calibrator generates unnecessary oscillations in a positive-going pressure step method. A dynamic high pressure calibrator, using a quick-opening ball valve, generates a fast step pressure change within 1 ms; however, the calibrator also generates a big impulse force that can lead to a short life-time of the system and to oscillating characteristics in response to the dynamic sensor to be calibrated. In this paper, unnecessary additional resonant frequencies besides those of the step function are characterized using frequency analysis. Accordingly, the main sources of resonance are described. In order to remove unnecessary frequencies, the post processing results, obtained by a filter, are given; also, a method for the modification of the dynamic calibration system is proposed.

  9. Research on ultrasonic excitation for the removal of drilling fluid plug, paraffin deposition plug, polymer plug and inorganic scale plug for near-well ultrasonic processing technology.

    PubMed

    Wang, Zhenjun; Zeng, Jing; Song, Hao; Li, Feng

    2017-05-01

    Near-well ultrasonic processing technology attracts more attention due to its simple operation, high adaptability, low cost and no pollution to the formation. Although this technology has been investigated in detail through laboratory experiments and field tests, systematic and intensive researches are absent for certain major aspects, such as whether ultrasonic excitation is better than chemical agent for any plugs removal; whether ultrasound-chemical combination plug removal technology has the best plugs removal effect. In this paper, the comparison of removing drilling fluid plug, paraffin deposition plug, polymer plug and inorganic scale plug using ultrasonic excitation, chemical agent and ultrasound-chemical combination plug removal technology is investigated. Results show that the initial core permeability and ultrasonic frequency play a significant role in plug removal. Ultrasonic excitation and chemical agent have different impact on different plugs. The comparison results show that the effect of removing any plugs using ultrasound-chemicals composite plug removal technology is obviously better than that using ultrasonic excitation or chemical agent alone. Such conclusion proves that ultrasonic excitation and chemical agent can cause synergetic effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Multichroic Bolometric Detector Architecture for Cosmic Microwave Background Polarimetry Experiments

    NASA Astrophysics Data System (ADS)

    Suzuki, Aritoki

    Characterization of the Cosmic Microwave Background (CMB) B-mode polarization signal will test models of inflationary cosmology, as well as constrain the sum of the neutrino masses and other cosmological parameters. The low intensity of the B-mode signal combined with the need to remove polarized galactic foregrounds requires a sensitive millimeter receiver and effective methods of foreground removal. Current bolometric detector technology is reaching the sensitivity limit set by the CMB photon noise. Thus, we need to increase the optical throughput to increase an experiment's sensitivity. To increase the throughput without increasing the focal plane size, we can increase the frequency coverage of each pixel. Increased frequency coverage per pixel has additional advantage that we can split the signal into frequency bands to obtain spectral information. The detection of multiple frequency bands allows for removal of the polarized foreground emission from synchrotron radiation and thermal dust emission, by utilizing its spectral dependence. Traditionally, spectral information has been captured with a multi-chroic focal plane consisting of a heterogeneous mix of single-color pixels. To maximize the efficiency of the focal plane area, we developed a multi-chroic pixel. This increases the number of pixels per frequency with same focal plane area. We developed multi-chroic antenna-coupled transition edge sensor (TES) detector array for the CMB polarimetry. In each pixel, a silicon lens-coupled dual polarized sinuous antenna collects light over a two-octave frequency band. The antenna couples the broadband millimeter wave signal into microstrip transmission lines, and on-chip filter banks split the broadband signal into several frequency bands. Separate TES bolometers detect the power in each frequency band and linear polarization. We will describe the design and performance of these devices and present optical data taken with prototype pixels and detector arrays. Our measurements show beams with percent level ellipticity, percent level cross-polarization leakage, and partitioned bands using banks of two and three filters. We will also describe the development of broadband anti-reflection coatings for the high dielectric constant lens. The broadband anti-reflection coating has approximately 100% bandwidth and no detectable loss at cryogenic temperature. We will describe a next generation CMB polarimetry experiment, the POLARBEAR-2, in detail. The POLARBEAR-2 would have focal planes with kilo-pixel of these detectors to achieve high sensitivity. We'll also introduce proposed experiments that would use multi-chroic detector array we developed in this work. We'll conclude by listing out suggestions for future multichroic detector development.

  11. Symmetry based frequency domain processing to remove harmonic noise from surface nuclear magnetic resonance measurements

    NASA Astrophysics Data System (ADS)

    Hein, Annette; Larsen, Jakob Juul; Parsekian, Andrew D.

    2017-02-01

    Surface nuclear magnetic resonance (NMR) is a unique geophysical method due to its direct sensitivity to water. A key limitation to overcome is the difficulty of making surface NMR measurements in environments with anthropogenic electromagnetic noise, particularly constant frequency sources such as powerlines. Here we present a method of removing harmonic noise by utilizing frequency domain symmetry of surface NMR signals to reconstruct portions of the spectrum corrupted by frequency-domain noise peaks. This method supplements the existing NMR processing workflow and is applicable after despiking, coherent noise cancellation, and stacking. The symmetry based correction is simple, grounded in mathematical theory describing NMR signals, does not introduce errors into the data set, and requires no prior knowledge about the harmonics. Modelling and field examples show that symmetry based noise removal reduces the effects of harmonics. In one modelling example, symmetry based noise removal improved signal-to-noise ratio in the data by 10 per cent. This improvement had noticeable effects on inversion parameters including water content and the decay constant T2*. Within water content profiles, aquifer boundaries and water content are more accurate after harmonics are removed. Fewer spurious water content spikes appear within aquifers, which is especially useful for resolving multilayered structures. Within T2* profiles, estimates are more accurate after harmonics are removed, especially in the lower half of profiles.

  12. A fast, robust algorithm for power line interference cancellation in neural recording.

    PubMed

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. The proposed algorithm features a highly robust operation, fast adaptation to interference variations, significant SNR improvement, low computational complexity and memory requirement and straightforward parameter adjustment. These features render the algorithm suitable for wearable and implantable sensor applications, where reliable and real-time cancellation of the interference is desired.

  13. A fast, robust algorithm for power line interference cancellation in neural recording

    NASA Astrophysics Data System (ADS)

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Objective. Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. Approach. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. Main results. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. Significance. The proposed algorithm features a highly robust operation, fast adaptation to interference variations, significant SNR improvement, low computational complexity and memory requirement and straightforward parameter adjustment. These features render the algorithm suitable for wearable and implantable sensor applications, where reliable and real-time cancellation of the interference is desired.

  14. Influence of the oscillation frequency of different side-to-side toothbrushes on noncontact biofilm removal.

    PubMed

    Schmidt, Julia C; Astasov-Frauenhoffer, Monika; Waltimo, Tuomas; Weiger, Roland; Walter, Clemens

    2018-01-22

    The objective of this study was to investigate the influence of different oscillation frequencies of three powered toothbrushes with side-to-side action for noncontact biofilm removal in an artificial interdental space model. A three-species biofilm (Porphyromonas gingivalis, Fusobacterium nucleatum and Streptococcus sanguinis) was formed in vitro on protein-coated titanium disks using a flow chamber system combined with a static biofilm growth model. The oscillation frequencies of three commercial side-to-side toothbrushes were evaluated by means of a dose response. The frequency was decreased in steps (100, 85, 70, 55, and 40%). Subsequently, the biofilm-coated substrates were exposed to the side-to-side toothbrushes. The biofilm volumes were measured using volumetric analyses (Imaris 8.1.2) with confocal laser scanning microscope images (Zeiss LSM700). Compared to maximum oscillation frequency (100%), lower oscillation frequencies (up to 40%) resulted in reduced median percentages of biofilm reduction (median biofilm reduction up to 53% for maximum oscillation frequency, and up to 13% for 40% oscillation frequency) (p ≥ 0.03). In addition, decreasing the oscillation frequencies of the side-to-side toothbrushes showed an enhanced variety in the results of repeated experiments. The oscillation frequency of the tested side-to-side toothbrushes affected the biofilm reduction in an interdental space model. Within a toothbrush, higher oscillation frequencies may lead to beneficial effects on interdental biofilm removal by noncontact brushing.

  15. An Attempt to Simulate Letter-by-Letter Dyslexia in Normal Readers

    ERIC Educational Resources Information Center

    Fiset, Stephanie; Arguin, Martin; Fiset, Daniel

    2006-01-01

    We attempted to simulate the main features of letter-by-letter (LBL) dyslexia in normal readers through stimulus degradation (i.e. contrast reduction and removal of high spatial frequencies). The results showed the word length and the letter confusability effects characteristic of LBL dyslexia. However, the interaction of letter confusability and…

  16. Managing air pollution impacted forests of California

    Treesearch

    Michael J. Arbaugh; Trent Proctor; Annie Esperanza

    2009-01-01

    Fuel treatments (prescribed fire and mechanical removal) on public lands in California are critical for reducing fuel accumulation and wildfire frequency and severity and protecting private property located in the wildland–urban interface. Treatments are especially needed in forests impacted by air pollution and subject to climate change. High ambient ozone (O

  17. Ground roll attenuation by synchrosqueezed curvelet transform

    NASA Astrophysics Data System (ADS)

    Liu, Zhao; Chen, Yangkang; Ma, Jianwei

    2018-04-01

    Ground roll is a type of coherent noise in land seismic data that has low frequency, low velocity and high amplitude. It damages reflection events that contain important information about subsurface structures, hence the removal of ground roll is a crucial step in seismic data processing. A suitable transform is needed for removal of ground roll. Curvelet transform is an effective sparse transform that optimally represents seismic events. In addition, the curvelets can provide a multiscale and multidirectional decomposition of the input data in time-frequency and angular domain, which can help distinguish between ground roll and useful signals. In this paper, we apply synchrosqueezed curvelet transform (SSCT) for ground roll attenuation. The synchrosqueezing technique in SSCT is used to precisely reallocate the energy of local wave vectors in order to separate ground roll from the original data with higher resolution and higher fidelity. Examples of synthetic and field seismic data reveal that SSCT performs well in the suppression of aliased and non-aliased ground roll while preserving reflection waves, in comparison with high-pass filtering, wavelet and curvelet methods.

  18. Electrocardiogram signal denoising based on empirical mode decomposition technique: an overview

    NASA Astrophysics Data System (ADS)

    Han, G.; Lin, B.; Xu, Z.

    2017-03-01

    Electrocardiogram (ECG) signal is nonlinear and non-stationary weak signal which reflects whether the heart is functioning normally or abnormally. ECG signal is susceptible to various kinds of noises such as high/low frequency noises, powerline interference and baseline wander. Hence, the removal of noises from ECG signal becomes a vital link in the ECG signal processing and plays a significant role in the detection and diagnosis of heart diseases. The review will describe the recent developments of ECG signal denoising based on Empirical Mode Decomposition (EMD) technique including high frequency noise removal, powerline interference separation, baseline wander correction, the combining of EMD and Other Methods, EEMD technique. EMD technique is a quite potential and prospective but not perfect method in the application of processing nonlinear and non-stationary signal like ECG signal. The EMD combined with other algorithms is a good solution to improve the performance of noise cancellation. The pros and cons of EMD technique in ECG signal denoising are discussed in detail. Finally, the future work and challenges in ECG signal denoising based on EMD technique are clarified.

  19. Push-Broom-Type Very High-Resolution Satellite Sensor Data Correction Using Combined Wavelet-Fourier and Multiscale Non-Local Means Filtering.

    PubMed

    Kang, Wonseok; Yu, Soohwan; Seo, Doochun; Jeong, Jaeheon; Paik, Joonki

    2015-09-10

    In very high-resolution (VHR) push-broom-type satellite sensor data, both destriping and denoising methods have become chronic problems and attracted major research advances in the remote sensing fields. Since the estimation of the original image from a noisy input is an ill-posed problem, a simple noise removal algorithm cannot preserve the radiometric integrity of satellite data. To solve these problems, we present a novel method to correct VHR data acquired by a push-broom-type sensor by combining wavelet-Fourier and multiscale non-local means (NLM) filters. After the wavelet-Fourier filter separates the stripe noise from the mixed noise in the wavelet low- and selected high-frequency sub-bands, random noise is removed using the multiscale NLM filter in both low- and high-frequency sub-bands without loss of image detail. The performance of the proposed method is compared to various existing methods on a set of push-broom-type sensor data acquired by Korean Multi-Purpose Satellite 3 (KOMPSAT-3) with severe stripe and random noise, and the results of the proposed method show significantly improved enhancement results over existing state-of-the-art methods in terms of both qualitative and quantitative assessments.

  20. Push-Broom-Type Very High-Resolution Satellite Sensor Data Correction Using Combined Wavelet-Fourier and Multiscale Non-Local Means Filtering

    PubMed Central

    Kang, Wonseok; Yu, Soohwan; Seo, Doochun; Jeong, Jaeheon; Paik, Joonki

    2015-01-01

    In very high-resolution (VHR) push-broom-type satellite sensor data, both destriping and denoising methods have become chronic problems and attracted major research advances in the remote sensing fields. Since the estimation of the original image from a noisy input is an ill-posed problem, a simple noise removal algorithm cannot preserve the radiometric integrity of satellite data. To solve these problems, we present a novel method to correct VHR data acquired by a push-broom-type sensor by combining wavelet-Fourier and multiscale non-local means (NLM) filters. After the wavelet-Fourier filter separates the stripe noise from the mixed noise in the wavelet low- and selected high-frequency sub-bands, random noise is removed using the multiscale NLM filter in both low- and high-frequency sub-bands without loss of image detail. The performance of the proposed method is compared to various existing methods on a set of push-broom-type sensor data acquired by Korean Multi-Purpose Satellite 3 (KOMPSAT-3) with severe stripe and random noise, and the results of the proposed method show significantly improved enhancement results over existing state-of-the-art methods in terms of both qualitative and quantitative assessments. PMID:26378532

  1. SEM investigations of the cementum surface after irradiation with a frequency-doubled Alexandrite laser

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas

    1996-04-01

    During prior studies it could be demonstrated while engaging a frequency doubled Alexandrite-laser (wavelength 380 nm, pulse duration 100 ns, fluence 1 J/cm2, pulse repetition rate 110 Hz) a fast and strictly selective ablation of supra- and subgingival calculus is possible. Even the removal of unstained microbial plaque was observed. First conclusions were drawn after light microscopical investigations on undecalcified sections of irradiated teeth. In the present study the cementum surface after irradiation with a frequency doubled Alexandrite-laser was observed by means of a Scanning Electron Microscope. After irradiation sections of teeth were dried in alcohol and sputtered with gold. In comparison irradiated cementum surfaces of unerupted operatively removed wisdom teeth and tooth surfaces after the selective removal of calculus were investigated. A complete removal of calculus was observed as well as a remaining smooth surface of irradiated cementum.

  2. Resonant-frequency discharge in a multi-cell radio frequency cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popovic, S; Upadhyay, J; Mammosser, J

    2014-11-07

    We are reporting experimental results on microwave discharge operating at resonant frequency in a multi-cell radio frequency (RF) accelerator cavity. Although the discharge operated at room temperature, the setup was constructed so that it could be used for plasma generation and processing in fully assembled active superconducting radio-frequency (SRF) cryomodule (in situ operation). This discharge offers an efficient mechanism for removal of a variety of contaminants, organic or oxide layers, and residual particulates from the interior surface of RF cavities through the interaction of plasma-generated radicals with the cavity walls. We describe resonant RF breakdown conditions and address the problemsmore » related to generation and sustaining the multi-cell cavity plasma, which are breakdown and resonant detuning. We have determined breakdown conditions in the cavity, which was acting as a plasma vessel with distorted cylindrical geometry. We discuss the spectroscopic data taken during plasma removal of contaminants and use them to evaluate plasma parameters, characterize the process, and estimate the volatile contaminant product removal.« less

  3. Measurement of electron density transients in pulsed RF discharges using a frequency boxcar hairpin probe

    NASA Astrophysics Data System (ADS)

    Peterson, David; Coumou, David; Shannon, Steven

    2015-11-01

    Time resolved electron density measurements in pulsed RF discharges are shown using a hairpin resonance probe using low cost electronics, on par with normal Langmuir probe boxcar mode operation. Time resolution of 10 microseconds has been demonstrated. A signal generator produces the applied microwave frequency; the reflected waveform is passed through a directional coupler and filtered to remove the RF component. The signal is heterodyned with a frequency mixer and rectified to produce a DC signal read by an oscilloscope. At certain points during the pulse, the plasma density is such that the applied frequency is the same as the resonance frequency of the probe/plasma system, creating reflected signal dips. The applied microwave frequency is shifted in small increments in a frequency boxcar routine to determine the density as a function of time. A dc sheath correction is applied for the grounded probe, producing low cost, high fidelity, and highly reproducible electron density measurements. The measurements are made in both inductively and capacitively coupled systems, the latter driven by multiple frequencies where a subset of these frequencies are pulsed. Measurements are compared to previous published results, time resolved OES, and in-line measurement of plasma impedance. This work is supported by the NSF DOE partnership on plasma science, the NSF GOALI program, and MKS Instruments.

  4. Electrochemical transformation of trichloroethylene in aqueous solution by electrode polarity reversal.

    PubMed

    Rajic, Ljiljana; Fallahpour, Noushin; Yuan, Songhu; Alshawabkeh, Akram N

    2014-12-15

    Electrode polarity reversal is evaluated for electrochemical transformation of trichloroethylene (TCE) in aqueous solution using flow-through reactors with mixed metal oxide electrodes and Pd catalyst. The study tests the hypothesis that optimizing electrode polarity reversal will generate H2O2 in Pd presence in the system. The effect of polarity reversal frequency, duration of the polarity reversal intervals, current intensity and TCE concentration on TCE removal rate and removal mechanism were evaluated. TCE removal efficiencies under 6 cycles h(-1) were similar in the presence of Pd catalyst (50.3%) and without Pd catalyst (49.8%), indicating that Pd has limited impact on TCE degradation under these conditions. The overall removal efficacies after 60 min treatment under polarity reversal frequencies of 6, 10, 15, 30 and 90 cycles h(-1) were 50.3%, 56.3%, 69.3%, 34.7% and 23.4%, respectively. Increasing the frequency of polarity reversal increases TCE removal as long as sufficient charge is produced during each cycle for the reaction at the electrode. Electrode polarity reversal shifts oxidation/reduction and reduction/oxidation sequences in the system. The optimized polarity reversal frequency (15 cycles h(-1) at 60 mA) enables two reaction zones formation where reduction/oxidation occurs at each electrode surface. Published by Elsevier Ltd.

  5. Electrochemical transformation of trichloroethylene in aqueous solution by electrode polarity reversal

    PubMed Central

    Rajic, Ljiljana; Fallahpour, Noushin; Yuan, Songhu; Alshawabkeh, Akram N.

    2014-01-01

    Electrode polarity reversal is evaluated for electrochemical transformation of trichloroethylene (TCE) in aqueous solution using flow-through reactors with mixed metal oxide electrodes and Pd catalyst. The study tests the hypothesis that optimizing electrode polarity reversal will generate H2O2 in Pd presence in the system. The effect of polarity reversal frequency, duration of the polarity reversal intervals, current intensity and TCE concentration on TCE removal rate and removal mechanism were evaluated. TCE removal efficiencies under 6 cycles h−1 were similar in the presence of Pd catalyst (50.3%) and without Pd catalyst (49.8%), indicating that Pd has limited impact on TCE degradation under these conditions. The overall removal efficacies after 60 min treatment under polarity reversal frequencies of 6, 10, 15, 30 and 90 cycles h−1 were 50.3%, 56.3%, 69.3%, 34.7% and 23.4%, respectively. Increasing the frequency of polarity reversal increases TCE removal as long as sufficient charge is produced during each cycle for the reaction at the electrode. Electrode polarity reversal shifts oxidation/reduction and reduction/oxidation sequences in the system. The optimized polarity reversal frequency (15 cycles h−1 at 60 mA) enables two reaction zones formation where reduction/oxidation occurs at each electrode surface. PMID:25282093

  6. A BASIC program for the removal of noise from reaction traces using Fourier filtering.

    PubMed

    Brittain, T

    1989-04-01

    Software for the removal of noise from reaction curves using the principle of Fourier filtering has been written in BASIC to execute on a PC. The program inputs reaction traces which are subjected to a rotation-inversion process, to produce functions suitable for Fourier analysis. Fourier transformation into the frequency domain is followed by multiplication of the transform by a rectangular filter function, to remove the noise frequencies. Inverse transformation then yields a noise-reduced reaction trace suitable for further analysis. The program is interactive at each stage and could easily be modified to remove noise from a range of input data types.

  7. Effects of Filtering on Experimental Blast Overpressure Measurements.

    PubMed

    Alphonse, Vanessa D; Kemper, Andrew R; Duma, Stefan M

    2015-01-01

    When access to live-fire test facilities is limited, experimental studies of blast-related injuries necessitate the use of a shock tube or Advanced Blast Simulator (ABS) to mimic free-field blast overpressure. However, modeling blast overpressure in a laboratory setting potentially introduces experimental artifacts in measured responses. Due to the high sampling rates required to capture a blast overpressure event, proximity to alternating current (AC-powered electronics) and poorly strain-relieved or unshielded wires can result in artifacts in the recorded overpressure trace. Data in this study were collected for tests conducted on an empty ABS (“Empty Tube”) using high frequency pressure sensors specifically designed for blast loading rates (n=5). Additionally, intraocular overpressure data (“IOP”) were collected for porcine eyes potted inside synthetic orbits located inside the ABS using an unshielded miniature pressure sensor (n=3). All tests were conducted at a 30 psi static overpressure level. A 4th order phaseless low pass Butterworth software filter was applied to the data. Various cutoff frequencies were examined to determine if the raw shock wave parameters values could be preserved while eliminating noise and artifacts. A Fast Fourier Transform (FFT) was applied to each test to examine the frequency spectra of the raw and filtered signals. Shock wave parameters (time of arrival, peak overpressure, positive duration, and positive impulse) were quantified using a custom MATLAB® script. Lower cutoff frequencies attenuated the raw signal, effectively decreasing the peak overpressure and increasing the positive duration. Rise time was not preserved the filtered data. A CFC 6000 filter preserved the remaining shock wave parameters within ±2.5% of the average raw values for the Empty Tube test data. A CFC 7000 filter removed experimental high-frequency artifacts and preserved the remaining shock wave parameters within ±2.5% of the average raw values for test IOP test data. Though the region of interest of the signals examined in the current study did not contain extremely high frequency content, it is possible that live-fire testing may produce shock waves with higher frequency content. While post-processing filtering can remove experimental artifacts, special care should be taken to minimize or eliminate the possibility of recording these artifacts in the first place.

  8. Membrane Electrical Noise in Chara corallina1

    PubMed Central

    Ross, Stephen; Dainty, Jack

    1986-01-01

    Certain inhibitors have been found to affect the low frequency spectral component of the electrical noise power spectrum in Chara corallina. Application of the ATPase inhibitor N,N′-dicyclohexylcarbodiimide removed the low frequency spectral component, strengthening the case that the component is produced by active proton pumping. Cytocholasin B, which inhibits cyclosis in internodes of C. corallina, removed the low frequency spectral component in a time-dependent fashion which was correlated with the cessation of streaming. The protonophore carbonyl cyanide m-chlorophenylhydrazone did not produce consistent effects on the low frequency spectral component in these cells. PMID:16664898

  9. Local Area Water Removal Analysis of a Proton Exchange Membrane Fuel Cell under Gas Purge Conditions

    PubMed Central

    Lee, Chi-Yuan; Lee, Yu-Ming; Lee, Shuo-Jen

    2012-01-01

    In this study, local area water content distribution under various gas purging conditions are experimentally analyzed for the first time. The local high frequency resistance (HFR) is measured using novel micro sensors. The results reveal that the liquid water removal rate in a membrane electrode assembly (MEA) is non-uniform. In the under-the-channel area, the removal of liquid water is governed by both convective and diffusive flux of the through-plane drying. Thus, almost all of the liquid water is removed within 30 s of purging with gas. However, liquid water that is stored in the under-the-rib area is not easy to remove during 1 min of gas purging. Therefore, the re-hydration of the membrane by internal diffusive flux is faster than that in the under-the-channel area. Consequently, local fuel starvation and membrane degradation can degrade the performance of a fuel cell that is started from cold. PMID:22368495

  10. A role for calcium hydroxide and dolomite in water: acceleration of the reaction under ultraviolet light.

    PubMed

    Nagase, Hiroyasu; Tsujino, Hidekazu; Kurihara, Daisuke; Saito, Hiroshi; Kawase, Masaya

    2014-04-01

    Organic environmental pollutants are now being detected with remarkably high frequency in the aquatic environment. Photodegradation by ultraviolet light is sometimes used as a method for removing organic chemicals from water; however, this method is relatively inefficient because of the low degradation rates involved, and more efficient methods are under development. Here we show that the removal of various organic pollutants can be assisted by calcined dolomite in aqueous solution under irradiation with ultraviolet light. It was possible to achieve substantial removal of bisphenol A, chlorophenols, alkylphenols, 1-naphthol and 17β-estradiol. The major component of dolomite responsible for the removal was calcium hydroxide. Our results demonstrate that the use of calcium hydroxide with ultraviolet light irradiation can be a very effective method of rapidly removing organic environmental pollutants from water. This is a new role for calcium hydroxide and dolomite in water treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Local area water removal analysis of a proton exchange membrane fuel cell under gas purge conditions.

    PubMed

    Lee, Chi-Yuan; Lee, Yu-Ming; Lee, Shuo-Jen

    2012-01-01

    In this study, local area water content distribution under various gas purging conditions are experimentally analyzed for the first time. The local high frequency resistance (HFR) is measured using novel micro sensors. The results reveal that the liquid water removal rate in a membrane electrode assembly (MEA) is non-uniform. In the under-the-channel area, the removal of liquid water is governed by both convective and diffusive flux of the through-plane drying. Thus, almost all of the liquid water is removed within 30 s of purging with gas. However, liquid water that is stored in the under-the-rib area is not easy to remove during 1 min of gas purging. Therefore, the re-hydration of the membrane by internal diffusive flux is faster than that in the under-the-channel area. Consequently, local fuel starvation and membrane degradation can degrade the performance of a fuel cell that is started from cold.

  12. Born approximation, multiple scattering, and butterfly algorithm

    NASA Astrophysics Data System (ADS)

    Martinez, Alex; Qiao, Zhijun

    2014-06-01

    Many imaging algorithms have been designed assuming the absence of multiple scattering. In the 2013 SPIE proceeding, we discussed an algorithm for removing high order scattering components from collected data. In this paper, our goal is to continue this work. First, we survey the current state of multiple scattering in SAR. Then, we revise our method and test it. Given an estimate of our target reflectivity, we compute the multi scattering effects in our target region for various frequencies. Furthermore, we propagate this energy through free space towards our antenna, and remove it from the collected data.

  13. Comparison of high-intensity sound and mechanical vibration for cleaning porous titanium cylinders fabricated using selective laser melting.

    PubMed

    Seiffert, Gary; Hopkins, Carl; Sutcliffe, Chris

    2017-01-01

    Orthopedic components, such as the acetabular cup in total hip joint replacement, can be fabricated using porous metals, such as titanium, and a number of processes, such as selective laser melting. The issue of how to effectively remove loose powder from the pores (residual powder) of such components has not been addressed in the literature. In this work, we investigated the feasibility of two processes, acoustic cleaning using high-intensity sound inside acoustic horns and mechanical vibration, to remove residual titanium powder from selective laser melting-fabricated cylinders. With acoustic cleaning, the amount of residual powder removed was not influenced by either the fundamental frequency of the horn used (75 vs. 230 Hz) or, for a given horn, the number of soundings (between 1 and 20). With mechanical vibration, the amount of residual powder removed was not influenced by the application time (10 vs. 20 s). Acoustic cleaning was found to be more reliable and effective in removal of residual powder than cleaning with mechanical vibration. It is concluded that acoustic cleaning using high-intensity sound has significant potential for use in the final preparation stages of porous metal orthopedic components. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 117-123, 2017. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  14. Effects of Removing Low-Frequency Electric Information on Speech Perception with Bimodal Hearing

    ERIC Educational Resources Information Center

    Fowler, Jennifer R.; Eggleston, Jessica L.; Reavis, Kelly M.; McMillan, Garnett P.; Reiss, Lina A. J.

    2016-01-01

    Purpose: The objective was to determine whether speech perception could be improved for bimodal listeners (those using a cochlear implant [CI] in one ear and hearing aid in the contralateral ear) by removing low-frequency information provided by the CI, thereby reducing acoustic-electric overlap. Method: Subjects were adult CI subjects with at…

  15. Obtaining phase velocity of turbulent boundary layer pressure fluctuations at high subsonic Mach number from wind tunnel data affected by strong background noise

    NASA Astrophysics Data System (ADS)

    Haxter, Stefan; Brouwer, Jens; Sesterhenn, Jörn; Spehr, Carsten

    2017-08-01

    Boundary layer measurements at high subsonic Mach number are evaluated in order to obtain the dominant phase velocities of boundary layer pressure fluctuations. The measurements were performed in a transonic wind tunnel which had a very strong background noise. The phase velocity was taken from phase inclination and from the convective peak in one- and two-dimensional wavenumber spectra. An approach was introduced to remove the acoustic noise from the data by applying a method based on CLEAN-SC on the two-dimensional spectra, thereby increasing the frequency range where information about the boundary layer was retrievable. A comparison with prediction models showed some discrepancies in the low-frequency range. Therefore, pressure data from a DNS calculation was used to substantiate the results of the analysis in this frequency range. Using the measured data, the DNS results and a review of the models used for comparison it was found that the phase velocity decreases at low frequencies.

  16. Accuracy Enhancement of Inertial Sensors Utilizing High Resolution Spectral Analysis

    PubMed Central

    Noureldin, Aboelmagd; Armstrong, Justin; El-Shafie, Ahmed; Karamat, Tashfeen; McGaughey, Don; Korenberg, Michael; Hussain, Aini

    2012-01-01

    In both military and civilian applications, the inertial navigation system (INS) and the global positioning system (GPS) are two complementary technologies that can be integrated to provide reliable positioning and navigation information for land vehicles. The accuracy enhancement of INS sensors and the integration of INS with GPS are the subjects of widespread research. Wavelet de-noising of INS sensors has had limited success in removing the long-term (low-frequency) inertial sensor errors. The primary objective of this research is to develop a novel inertial sensor accuracy enhancement technique that can remove both short-term and long-term error components from inertial sensor measurements prior to INS mechanization and INS/GPS integration. A high resolution spectral analysis technique called the fast orthogonal search (FOS) algorithm is used to accurately model the low frequency range of the spectrum, which includes the vehicle motion dynamics and inertial sensor errors. FOS models the spectral components with the most energy first and uses an adaptive threshold to stop adding frequency terms when fitting a term does not reduce the mean squared error more than fitting white noise. The proposed method was developed, tested and validated through road test experiments involving both low-end tactical grade and low cost MEMS-based inertial systems. The results demonstrate that in most cases the position accuracy during GPS outages using FOS de-noised data is superior to the position accuracy using wavelet de-noising.

  17. Hair today, gone tomorrow: a comparison of body hair removal practices in gay and heterosexual men.

    PubMed

    Martins, Yolanda; Tiggemann, Marika; Churchett, Libby

    2008-09-01

    Although hairlessness is rapidly becoming a component of the ideal male body, little research has examined men's concerns about their body hair or their hair removal practices. Samples of gay and heterosexual men completed questionnaires that assessed whether they had ever removed their back, buttock or pubic hair, the frequency with which they did so, the methods used and their self-reported reasons for removing this hair, as well as their level of appearance investment. Results indicated that many gay and heterosexual men remove their back, buttock and pubic hair regularly and that their primary reason for doing so is to maintain or improve their appearance. The frequency of hair removal was also associated with the motivational salience component of appearance investment. The findings offer further support to the premise that gay and heterosexual men exhibit similar body image concerns.

  18. A procedure for removing the effect of response bias errors from waterfowl hunter questionnaire responses

    USGS Publications Warehouse

    Atwood, E.L.

    1958-01-01

    Response bias errors are studied by comparing questionnaire responses from waterfowl hunters using four large public hunting areas with actual hunting data from these areas during two hunting seasons. To the extent that the data permit, the sources of the error in the responses were studied and the contribution of each type to the total error was measured. Response bias errors, including both prestige and memory bias, were found to be very large as compared to non-response and sampling errors. Good fits were obtained with the seasonal kill distribution of the actual hunting data and the negative binomial distribution and a good fit was obtained with the distribution of total season hunting activity and the semi-logarithmic curve. A comparison of the actual seasonal distributions with the questionnaire response distributions revealed that the prestige and memory bias errors are both positive. The comparisons also revealed the tendency for memory bias errors to occur at digit frequencies divisible by five and for prestige bias errors to occur at frequencies which are multiples of the legal daily bag limit. A graphical adjustment of the response distributions was carried out by developing a smooth curve from those frequency classes not included in the predictable biased frequency classes referred to above. Group averages were used in constructing the curve, as suggested by Ezekiel [1950]. The efficiency of the technique described for reducing response bias errors in hunter questionnaire responses on seasonal waterfowl kill is high in large samples. The graphical method is not as efficient in removing response bias errors in hunter questionnaire responses on seasonal hunting activity where an average of 60 percent was removed.

  19. The Advanced ACTPol 27/39 GHz Array

    NASA Astrophysics Data System (ADS)

    Simon, S. M.; Beall, J. A.; Cothard, N. F.; Duff, S. M.; Gallardo, P. A.; Ho, S. P.; Hubmayr, J.; Koopman, B. J.; McMahon, J. J.; Nati, F.; Niemack, M. D.; Staggs, S. T.; Vavagiakis, E. M.; Wollack, E. J.

    2018-05-01

    Advanced ACTPol (AdvACT) will observe the temperature and polarization of the cosmic microwave background (CMB) at multiple frequencies and high resolution to place improved constraints on inflation, dark matter, and dark energy. Foregrounds from synchrotron and dust radiation are a source of contamination that must be characterized and removed across a wide range of frequencies. AdvACT will thus observe at five frequency bands from 27 to 230 GHz. We discuss the design of the pixels and feedhorns for the 27/39 GHz multichroic array for AdvACT, which will target the synchrotron radiation that dominates at these frequencies. To gain 35% in mapping speed in the 39 GHz band where the foreground signals are faintest, the pixel number was increased through reducing the pixel diameter to 1.08λ at the lowest frequency, which represents a 22% decrease in size compared to our previously most tightly packed pixels.

  20. Assessment of sound quality perception in cochlear implant users during music listening.

    PubMed

    Roy, Alexis T; Jiradejvong, Patpong; Carver, Courtney; Limb, Charles J

    2012-04-01

    Although cochlear implant (CI) users frequently report deterioration of sound quality when listening to music, few methods exist to quantify these subjective claims. 1) To design a novel research method for quantifying sound quality perception in CI users during music listening; 2) To validate this method by assessing one attribute of music perception, bass frequency perception, which is hypothesized to be relevant to overall musical sound quality perception. Limitations in bass frequency perception contribute to CI-mediated sound quality deteriorations. The proposed method will quantify this deterioration by measuring CI users' impaired ability to make sound quality discriminations among musical stimuli with variable amounts of bass frequency removal. A method commonly used in the audio industry (multiple stimulus with hidden reference and anchor [MUSHRA]) was adapted for CI users, referred to as CI-MUSHRA. CI users and normal hearing controls were presented with 7 sound quality versions of a musical segment: 5 high pass filter cutoff versions (200-, 400-, 600-, 800-, 1000-Hz) with decreasing amounts of bass information, an unaltered version ("hidden reference"), and a highly altered version (1,000-1,200 Hz band pass filter; "anchor"). Participants provided sound quality ratings between 0 (very poor) and 100 (excellent) for each version; ratings reflected differences in perceived sound quality among stimuli. CI users had greater difficulty making overall sound quality discriminations as a function of bass frequency loss than normal hearing controls, as demonstrated by a significantly weaker correlation between bass frequency content and sound quality ratings. In particular, CI users could not perceive sound quality difference among stimuli missing up to 400 Hz of bass frequency information. Bass frequency impairments contribute to sound quality deteriorations during music listening for CI users. CI-MUSHRA provided a systematic and quantitative assessment of this reduced sound quality. Although the effects of bass frequency removal were studied here, we advocate CI-MUSHRA as a user-friendly and versatile research tool to measure the effects of a wide range of acoustic manipulations on sound quality perception in CI users.

  1. Interaction of charge carriers with lattice and molecular phonons in crystalline pentacene

    NASA Astrophysics Data System (ADS)

    Girlando, Alberto; Grisanti, Luca; Masino, Matteo; Brillante, Aldo; Della Valle, Raffaele G.; Venuti, Elisabetta

    2011-08-01

    The computational protocol we have developed for the calculation of local (Holstein) and non-local (Peierls) carrier-phonon coupling in molecular organic semiconductors is applied to both the low temperature and high temperature bulk crystalline phases of pentacene. The electronic structure is calculated by the semimpirical INDO/S (Intermediate Neglect of Differential Overlap with Spectroscopic parametrization) method. In the phonon description, the rigid molecule approximation is removed, allowing mixing of low-frequency intra-molecular modes with inter-molecular (lattice) phonons. A clear distinction remains between the low-frequency phonons, which essentially modulate the transfer integral from a molecule to another (Peierls coupling), and the high-frequency intra-molecular phonons, which modulate the on-site energy (Holstein coupling). The results of calculation agree well with the values extracted from experiment. The comparison with similar calculations made for rubrene allows us to discuss the implications for the current models of mobility.

  2. High field Q slope and the effect of low-temperature baking at 3 GHz

    NASA Astrophysics Data System (ADS)

    Ciovati, G.; Eremeev, G.; Hannon, F.

    2018-01-01

    A strong degradation of the unloaded quality factor with field, called high field Q slope, is commonly observed above Bp ≅100 mT in elliptical superconducting niobium cavities at 1.3 and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above Bp ≅100 mT . The measurements show that a high field Q slope phenomenon limits the field reach at this frequency, that the high field Q slope onset field depends weakly on the frequency, and that the high field Q slope can be removed by the typical empirical solution of electropolishing followed by heating to 120°C for 48 hrs. In addition, one of the cavities reached a quench field of 174 mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.

  3. A baseline drift detrending technique for fast scan cyclic voltammetry.

    PubMed

    DeWaele, Mark; Oh, Yoonbae; Park, Cheonho; Kang, Yu Min; Shin, Hojin; Blaha, Charles D; Bennet, Kevin E; Kim, In Young; Lee, Kendall H; Jang, Dong Pyo

    2017-11-06

    Fast scan cyclic voltammetry (FSCV) has been commonly used to measure extracellular neurotransmitter concentrations in the brain. Due to the unstable nature of the background currents inherent in FSCV measurements, analysis of FSCV data is limited to very short amounts of time using traditional background subtraction. In this paper, we propose the use of a zero-phase high pass filter (HPF) as the means to remove the background drift. Instead of the traditional method of low pass filtering across voltammograms to increase the signal to noise ratio, a HPF with a low cutoff frequency was applied to the temporal dataset at each voltage point to remove the background drift. As a result, the HPF utilizing cutoff frequencies between 0.001 Hz and 0.01 Hz could be effectively used to a set of FSCV data for removing the drifting patterns while preserving the temporal kinetics of the phasic dopamine response recorded in vivo. In addition, compared to a drift removal method using principal component analysis, this was found to be significantly more effective in reducing the drift (unpaired t-test p < 0.0001, t = 10.88) when applied to data collected from Tris buffer over 24 hours although a drift removal method using principal component analysis also showed the effective background drift reduction. The HPF was also applied to 5 hours of FSCV in vivo data. Electrically evoked dopamine peaks, observed in the nucleus accumbens, were clearly visible even without background subtraction. This technique provides a new, simple, and yet robust, approach to analyse FSCV data with an unstable background.

  4. The effect of prophylactic antibiotic treatment for manual removal of the placenta on frequency of postpartum endometritis.

    PubMed

    Safrai, Myriam; Kabiri, Doron; Haj-Yahya, Rani; Reuveni-Salzman, Adi; Lipschuetz, Michal; Ezra, Yossef

    2017-10-01

    To determine whether prophylactic antibiotics reduce the frequency of postpartum endometritis after manual removal of the placenta. A retrospective cohort study was conducted using data for all women who underwent manual removal of the placenta after vaginal delivery at a tertiary medical center in Jerusalem, Israel, between January 1, 2010, and December 31, 2015. The study group comprised women who had not received prophylactic antibiotic treatment, whereas the control group comprised women who had received prophylactic antibiotic treatment. The primary outcome measure was the frequency of postpartum endometritis. Of the 407 women included in the analysis, 7 (1.7%) developed postpartum endometritis. Six of the women with postpartum endometritis had received prophylactic treatment with antibiotics, whereas one woman had not (odds ratio 0.555, 95% confidence interval 0.065-4.630). Prophylactic antibiotics before manual removal of the placenta did not decrease the odds of postpartum endometritis. © 2017 International Federation of Gynecology and Obstetrics.

  5. A Novel AMARS Technique for Baseline Wander Removal Applied to Photoplethysmogram.

    PubMed

    Timimi, Ammar A K; Ali, M A Mohd; Chellappan, K

    2017-06-01

    A new digital filter, AMARS (aligning minima of alternating random signal) has been derived using trigonometry to regulate signal pulsations inline. The pulses are randomly presented in continuous signals comprising frequency band lower than the signal's mean rate. Frequency selective filters are conventionally employed to reject frequencies undesired by specific applications. However, these conventional filters only reduce the effects of the rejected range producing a signal superimposed by some baseline wander (BW). In this work, filters of different ranges and techniques were independently configured to preprocess a photoplethysmogram, an optical biosignal of blood volume dynamics, producing wave shapes with several BWs. The AMARS application effectively removed the encountered BWs to assemble similarly aligned trends. The removal implementation was found repeatable in both ear and finger photoplethysmograms, emphasizing the importance of BW removal in biosignal processing in retaining its structural, functional and physiological properties. We also believe that AMARS may be relevant to other biological and continuous signals modulated by similar types of baseline volatility.

  6. Knowledge discovery from high-frequency stream nitrate concentrations: hydrology and biology contributions.

    PubMed

    Aubert, Alice H; Thrun, Michael C; Breuer, Lutz; Ultsch, Alfred

    2016-08-30

    High-frequency, in-situ monitoring provides large environmental datasets. These datasets will likely bring new insights in landscape functioning and process scale understanding. However, tailoring data analysis methods is necessary. Here, we detach our analysis from the usual temporal analysis performed in hydrology to determine if it is possible to infer general rules regarding hydrochemistry from available large datasets. We combined a 2-year in-stream nitrate concentration time series (time resolution of 15 min) with concurrent hydrological, meteorological and soil moisture data. We removed the low-frequency variations through low-pass filtering, which suppressed seasonality. We then analyzed the high-frequency variability component using Pareto Density Estimation, which to our knowledge has not been applied to hydrology. The resulting distribution of nitrate concentrations revealed three normally distributed modes: low, medium and high. Studying the environmental conditions for each mode revealed the main control of nitrate concentration: the saturation state of the riparian zone. We found low nitrate concentrations under conditions of hydrological connectivity and dominant denitrifying biological processes, and we found high nitrate concentrations under hydrological recession conditions and dominant nitrifying biological processes. These results generalize our understanding of hydro-biogeochemical nitrate flux controls and bring useful information to the development of nitrogen process-based models at the landscape scale.

  7. Holographic radar imaging privacy techniques utilizing dual-frequency implementation

    NASA Astrophysics Data System (ADS)

    McMakin, Douglas L.; Hall, Thomas E.; Sheen, David M.

    2008-04-01

    Over the last 15 years, the Pacific Northwest National Laboratory has performed significant research and development activities to enhance the state of the art of holographic radar imaging systems to be used at security checkpoints for screening people for concealed threats hidden under their garments. These enhancement activities included improvements to privacy techniques to remove human features and providing automatic detection of body-worn concealed threats. The enhanced privacy and detection methods used both physical and software imaging techniques. The physical imaging techniques included polarization-diversity illumination and reception, dual-frequency implementation, and high-frequency imaging at 60 GHz. Software imaging techniques to enhance the privacy of the person under surveillance included extracting concealed threat artifacts from the imagery to automatically detect the threat. This paper will focus on physical privacy techniques using dual-frequency implementation.

  8. Holographic Radar Imaging Privacy Techniques Utilizing Dual-Frequency Implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMakin, Douglas L.; Hall, Thomas E.; Sheen, David M.

    2008-04-18

    Over the last 15 years, the Pacific Northwest National Laboratory has performed significant research and development activities to enhance the state of the art of holographic radar imaging systems to be used at security checkpoints for screening people for concealed threats hidden under their garments. These enhancement activities included improvements to privacy techniques to remove human features and providing automatic detection of body-worn concealed threats. The enhanced privacy and detection methods used both physical and software imaging techniques. The physical imaging techniques included polarization-diversity illumination and reception, dual-frequency implementation, and high-frequency imaging at 60 GHz. Software imaging techniques to enhancemore » the privacy of the person under surveillance included extracting concealed threat artifacts from the imagery to automatically detect the threat. This paper will focus on physical privacy techniques using dual-frequency implementation.« less

  9. Decision-aided ICI mitigation with time-domain average approximation in CO-OFDM

    NASA Astrophysics Data System (ADS)

    Ren, Hongliang; Cai, Jiaxing; Ye, Xin; Lu, Jin; Cao, Quanjun; Guo, Shuqin; Xue, Lin-lin; Qin, Yali; Hu, Weisheng

    2015-07-01

    We introduce and investigate the feasibility of a novel iterative blind phase noise inter-carrier interference (ICI) mitigation scheme for coherent optical orthogonal frequency division multiplexing (CO-OFDM) systems. The ICI mitigation scheme is performed through the combination of frequency-domain symbol decision-aided estimation and the ICI phase noise time-average approximation. An additional initial decision process with suitable threshold is introduced in order to suppress the decision error symbols. Our proposed ICI mitigation scheme is proved to be effective in removing the ICI for a simulated CO-OFDM with 16-QAM modulation format. With the slightly high computational complexity, it outperforms the time-domain average blind ICI (Avg-BL-ICI) algorithm at a relatively wide laser line-width and high OSNR.

  10. High-frequency characterization and modeling of single metallic nanowires

    NASA Astrophysics Data System (ADS)

    Hsu, Chuan-Lun; Ardila, Gustavo; Benech, Philippe

    2013-07-01

    The transmission line characteristics of an individual aluminum metallic nanowire up to 100 GHz are presented in this paper. We have built a reliable framework for characterizing such nanowires using a specially designed coplanar waveguide platform. We systematically estimate the pad parasitics, contact impedance and transmission line parameters based on an equivalent circuit model and cascade-based de-embedding theory. This is the first time that such external parasitic elements have been successfully removed from a nanoscale transmission line. The extracted frequency-dependent electrical responses show good signal levels and a high degree of reproducibility. Contribution to the Topical Issue “International Semiconductor Conference Dresden-Grenoble - ISCDG 2012”, Edited by Gérard Ghibaudo, Francis Balestra and Simon Deleonibus.

  11. Effects on Diagnostic Parameters After Removing Additional Synchronous Gear Meshes

    NASA Technical Reports Server (NTRS)

    Decker, Harry J.

    2003-01-01

    Gear cracks are typically difficult to diagnose with sufficient time before catastrophic damage occurs. Significant damage must be present before algorithms appear to be able to detect the damage. Frequently there are multiple gear meshes on a single shaft. Since they are all synchronous with the shaft frequency, the commonly used synchronous averaging technique is ineffective in removing other gear mesh effects. Carefully applying a filter to these extraneous gear mesh frequencies can reduce the overall vibration signal and increase the accuracy of commonly used vibration metrics. The vibration signals from three seeded fault tests were analyzed using this filtering procedure. Both the filtered and unfiltered vibration signals were then analyzed using commonly used fault detection metrics and compared. The tests were conducted on aerospace quality spur gears in a test rig. The tests were conducted at speeds ranging from 2500 to 5000 revolutions per minute and torques from 184 to 228 percent of design load. The inability to detect these cracks with high confidence results from the high loading which is causing fast fracture as opposed to stable crack growth. The results indicate that these techniques do not currently produce an indication of damage that significantly exceeds experimental scatter.

  12. Photolysis of low concentration H2S under UV/VUV irradiation emitted from high frequency discharge electrodeless lamps.

    PubMed

    Xu, Jianhui; Li, Chaolin; Liu, Peng; He, Di; Wang, Jianfeng; Zhang, Qian

    2014-08-01

    The photolysis of low concentration of H2S malodorous gas was studied under UV irradiation emitted by self-made high frequency discharge electrodeless lamp with atomic mercury lines at 185/253.7nm. Experiments results showed that the removal efficiency (ηH2S) of H2S was decreased with increasing initial H2S concentration and increased slightly with gas residence time. ηH2S was increased dramatically with relative humidity from<5% to 43% while the concentration of oxygen in gas environments affected the removal of H2S. The mechanisms for direct and indirect photolysis (generation of ozone) were illustrated by the experimental results on photolysis of H2S under argon environments and ozonation of H2S under air environments, respectively. The overall ηH2S by photolysis is higher than the combination of ηH2S by direct photolysis and ozonation, suggesting that hydroxyl radical-mediated indirect photolysis played an important role during photolysis processes. The main photolysis product was confirmed to be SO4(2-) with ion chromatograph. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Microearthquake spectra from the Anza, California, seismic network: site response and source scaling

    USGS Publications Warehouse

    Frankel, Arthur D.; Wennerberg, Leif

    1989-01-01

    We analyzed spectra of local microearthquakes recorded by the Anza, California, seismic network to isolate the effects of site response and to investigate the scaling of source parameters for small earthquakes. Spectra of microearthquakes (M < 2; Mo< 1019 dyne-cm) at Anza have shapes characteristic of the receiver sites and are generally independent of the source region. Thus, the site response is a major conditioner of the observed spectral shape. To remove the effects of site response from the spectra of a M ∼ 3 event and isolate its source spectrum, we divided by the spectra of an adjacent aftershock used as an empirical Green's function event. The spectral ratios indicate that the apparent corner frequencies of small earthquakes (Mo < 1019dyne-cm) observed at even the high-fmax stations on hard rock are much lower than the source corner frequencies. The spectral ratios are consistent with stress drop remaining constant with decreasing seismic moment, for events with moments as small as 1018 dyne-cm. The spectral ratios display remarkable agreement between sites which showed vast differences in their original spectra, indicating that the spectral division effectively removed the site response. The source spectrum of the M ∼ 3 event has a high-frequency spectral fall-off of about ω−2. An apparent dependence of high-frequency fall-off with seismic moment in the original spectra can also be explained by the effects of site response. The difference between the P- and S-wave corner frequencies and high-frequency roll-offs in the observed spectra for these events is the result of the site response and is not a source property. The shapes of the spectra of microearthquakes at Anza can largely be explained by attenuation at shallow depth with a frequency-independent Q. For some sites, near-surface resonances are also apparent in the spectra of microearthquakes. It is indicated by t* values determined for each site that Qp ∼ Qsfor the shallow low-Q layer. Further evidence of low near-surface Q is observed in the anomalous spectra of an unusually shallow earthquake (source depth ∼ 1 km) in the network. The spectra from this shallow event are depleted in high-frequency energy at most stations, relative to those of deeper events. This observation can be explained by a low-Q surficial zone. For stations of the network situated on alluvium, this low-Q layer has a maximum thickness of about 3 km and maximum P- and S-wave Q values of 30 to 50.

  14. The Exponent of High-frequency Source Spectral Falloff and Contribution to Source Parameter Estimates

    NASA Astrophysics Data System (ADS)

    Kiuchi, R.; Mori, J. J.

    2015-12-01

    As a way to understand the characteristics of the earthquake source, studies of source parameters (such as radiated energy and stress drop) and their scaling are important. In order to estimate source parameters reliably, often we must use appropriate source spectrum models and the omega-square model is most frequently used. In this model, the spectrum is flat in lower frequencies and the falloff is proportional to the angular frequency squared. However, Some studies (e.g. Allmann and Shearer, 2009; Yagi et al., 2012) reported that the exponent of the high frequency falloff is other than -2. Therefore, in this study we estimate the source parameters using a spectral model for which the falloff exponent is not fixed. We analyze the mainshock and larger aftershocks of the 2008 Iwate-Miyagi Nairiku earthquake. Firstly, we calculate the P wave and SH wave spectra using empirical Green functions (EGF) to remove the path effect (such as attenuation) and site effect. For the EGF event, we select a smaller earthquake that is highly-correlated with the target event. In order to obtain the stable results, we calculate the spectral ratios using a multitaper spectrum analysis (Prieto et al., 2009). Then we take a geometric mean from multiple stations. Finally, using the obtained spectra ratios, we perform a grid search to determine the high frequency falloffs, as well as corner frequency of both of events. Our results indicate the high frequency falloff exponent is often less than 2.0. We do not observe any regional, focal mechanism, or depth dependencies for the falloff exponent. In addition, our estimated corner frequencies and falloff exponents are consistent between the P wave and SH wave analysis. In our presentation, we show differences in estimated source parameters using a fixed omega-square model and a model allowing variable high-frequency falloff.

  15. Signature of nonadiabatic coupling in excited-state vibrational modes.

    PubMed

    Soler, Miguel A; Nelson, Tammie; Roitberg, Adrian E; Tretiak, Sergei; Fernandez-Alberti, Sebastian

    2014-11-13

    Using analytical excited-state gradients, vibrational normal modes have been calculated at the minimum of the electronic excited-state potential energy surfaces for a set of extended conjugated molecules with different coupling between them. Molecular model systems composed of units of polyphenylene ethynylene (PPE), polyphenylenevinylene (PPV), and naphthacene/pentacene (NP) have been considered. In all cases except the NP model, the influence of the nonadiabatic coupling on the excited-state equilibrium normal modes is revealed as a unique highest frequency adiabatic vibrational mode that overlaps with the coupling vector. This feature is removed by using a locally diabatic representation in which the effect of NA interaction is removed. Comparison of the original adiabatic modes with a set of vibrational modes computed in the locally diabatic representation demonstrates that the effect of nonadiabaticity is confined to only a few modes. This suggests that the nonadiabatic character of a molecular system may be detected spectroscopically by identifying these unique state-specific high frequency vibrational modes.

  16. Gradient-Induced Voltages on 12-Lead ECGs during High Duty-Cycle MRI Sequences and a Method for Their Removal considering Linear and Concomitant Gradient Terms

    PubMed Central

    Zhang, Shelley HuaLei; Ho Tse, Zion Tsz; Dumoulin, Charles L.; Kwong, Raymond Y.; Stevenson, William G.; Watkins, Ronald; Ward, Jay; Wang, Wei; Schmidt, Ehud J.

    2015-01-01

    Purpose To restore 12-lead ECG signal fidelity inside MRI by removing magnetic-field gradient induced-voltages during high gradient-duty-cycle sequences. Theory and Methods A theoretical equation was derived, providing first- and second-order electrical fields induced at individual ECG electrode as a function of gradient fields. Experiments were performed at 3T on healthy volunteers, using a customized acquisition system which captured full amplitude and frequency response of ECGs, or a commercial recording system. The 19 equation coefficients were derived by linear regression of data from accelerated sequences, and used to compute induced-voltages in real-time during full-resolution sequences to remove ECG artifacts. Restored traces were evaluated relative to ones acquired without imaging. Results Measured induced-voltages were 0.7V peak-to-peak during balanced Steady-State Free Precession (bSSFP) with heart at the isocenter. Applying the equation during gradient echo sequencing, three-dimensional fast spin echo and multi-slice bSSFP imaging restored nonsaturated traces and second-order concomitant terms showed larger contributions in electrodes farther from the magnet isocenter. Equation coefficients are evaluated with high repeatability (ρ = 0.996) and are subject, sequence, and slice-orientation dependent. Conclusion Close agreement between theoretical and measured gradient-induced voltages allowed for real-time removal. Prospective estimation of sequence-periods where large induced-voltages occur may allow hardware removal of these signals. PMID:26101951

  17. Notch filtering the nuclear environment of a spin qubit.

    PubMed

    Malinowski, Filip K; Martins, Frederico; Nissen, Peter D; Barnes, Edwin; Cywiński, Łukasz; Rudner, Mark S; Fallahi, Saeed; Gardner, Geoffrey C; Manfra, Michael J; Marcus, Charles M; Kuemmeth, Ferdinand

    2017-01-01

    Electron spins in gate-defined quantum dots provide a promising platform for quantum computation. In particular, spin-based quantum computing in gallium arsenide takes advantage of the high quality of semiconducting materials, reliability in fabricating arrays of quantum dots and accurate qubit operations. However, the effective magnetic noise arising from the hyperfine interaction with uncontrolled nuclear spins in the host lattice constitutes a major source of decoherence. Low-frequency nuclear noise, responsible for fast (10 ns) inhomogeneous dephasing, can be removed by echo techniques. High-frequency nuclear noise, recently studied via echo revivals, occurs in narrow-frequency bands related to differences in Larmor precession of the three isotopes 69 Ga, 71 Ga and 75 As (refs 15,16,17). Here, we show that both low- and high-frequency nuclear noise can be filtered by appropriate dynamical decoupling sequences, resulting in a substantial enhancement of spin qubit coherence times. Using nuclear notch filtering, we demonstrate a spin coherence time (T 2 ) of 0.87 ms, five orders of magnitude longer than typical exchange gate times, and exceeding the longest coherence times reported to date in Si/SiGe gate-defined quantum dots.

  18. Simultaneous removals of NOx, HC and PM from diesel exhaust emissions by dielectric barrier discharges.

    PubMed

    Song, Chong-Lin; Bin, Feng; Tao, Ze-Min; Li, Fang-Cheng; Huang, Qi-Fei

    2009-07-15

    The main target of this work is to characterize the abatements of particulate matter (PM), hydrocarbons (HC) and nitrogen oxides (NO(x)) from an actual diesel exhaust using dielectric barrier discharge technology (DBD). The effects of several parameters, such as peak voltage, frequency and engine load, on the contaminant removals have been investigated intensively. The present study shows that for a given frequency, the removals of PM and HC are enhanced with the increase of peak voltage and level off at higher voltage, while in the range of higher voltages a decline of NO(x) removal efficiency is observed. For a given voltage, the maximums of specific energy density (SED) and removal efficiency are attained at resonance point. The increase of peak voltage will result in a significant decrease of energy utilization efficiency of DBD at most engine loads. Alkanes in soluble organic fraction (SOF) are more readily subjected to removals than polycyclic aromatic hydrocarbons (PAHs).

  19. Description of A 2.3 kW power transformer for space applications

    NASA Technical Reports Server (NTRS)

    Hansen, I.

    1979-01-01

    The paper describes the principal features and special testing of a high-frequency high-power low-specific-weight (0.57 kg/kW) 2.3-kW electronic power transformer developed for space applications. The transformer is operated in a series resonant inverter supplying beam power to a 30-cm mercury ion thruster. High efficiency (above 98.5%) is obtained through careful detailed design. A number of unique heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

  20. Digital hum filtering

    USGS Publications Warehouse

    Knapp, R.W.; Anderson, N.L.

    1994-01-01

    Data may be overprinted by a steady-state cyclical noise (hum). Steady-state indicates that the noise is invariant with time; its attributes, frequency, amplitude, and phase, do not change with time. Hum recorded on seismic data usually is powerline noise and associated higher harmonics; leakage from full-waveform rectified cathodic protection devices that contain the odd higher harmonics of powerline frequencies; or vibrational noise from mechanical devices. The fundamental frequency of powerline hum may be removed during data acquisition with the use of notch filters. Unfortunately, notch filters do not discriminate signal and noise, attenuating both. They also distort adjacent frequencies by phase shifting. Finally, they attenuate only the fundamental mode of the powerline noise; higher harmonics and frequencies other than that of powerlines are not removed. Digital notch filters, applied during processing, have many of the same problems as analog filters applied in the field. The method described here removes hum of a particular frequency. Hum attributes are measured by discrete Fourier analysis, and the hum is canceled from the data by subtraction. Errors are slight and the result of the presence of (random) noise in the window or asynchrony of the hum and data sampling. Error is minimized by increasing window size or by resampling to a finer interval. Errors affect the degree of hum attenuation, not the signal. The residual is steady-state hum of the same frequency. ?? 1994.

  1. A Modified Differential Coherent Bit Synchronization Algorithm for BeiDou Weak Signals with Large Frequency Deviation.

    PubMed

    Han, Zhifeng; Liu, Jianye; Li, Rongbing; Zeng, Qinghua; Wang, Yi

    2017-07-04

    BeiDou system navigation messages are modulated with a secondary NH (Neumann-Hoffman) code of 1 kbps, where frequent bit transitions limit the coherent integration time to 1 millisecond. Therefore, a bit synchronization algorithm is necessary to obtain bit edges and NH code phases. In order to realize bit synchronization for BeiDou weak signals with large frequency deviation, a bit synchronization algorithm based on differential coherent and maximum likelihood is proposed. Firstly, a differential coherent approach is used to remove the effect of frequency deviation, and the differential delay time is set to be a multiple of bit cycle to remove the influence of NH code. Secondly, the maximum likelihood function detection is used to improve the detection probability of weak signals. Finally, Monte Carlo simulations are conducted to analyze the detection performance of the proposed algorithm compared with a traditional algorithm under the CN0s of 20~40 dB-Hz and different frequency deviations. The results show that the proposed algorithm outperforms the traditional method with a frequency deviation of 50 Hz. This algorithm can remove the effect of BeiDou NH code effectively and weaken the influence of frequency deviation. To confirm the feasibility of the proposed algorithm, real data tests are conducted. The proposed algorithm is suitable for BeiDou weak signal bit synchronization with large frequency deviation.

  2. Interactions between Super Typhoon Megi (2010) and the Monsoon Gyre

    NASA Astrophysics Data System (ADS)

    Peng, M.; Li, T.; Bi, M.; Shen, X.

    2015-12-01

    Accurate prediction of tropical cyclone track is critical for high-impact weather preparedness, especially as the storm is near the coastal region. The track prediction for super typhoon Megi (2010) in the western Pacific was notoriously bad as most operational models predicated a mainly westward movement while Megi actually made a northward turning after it has crossed the Philippines islands. In this study, we try to understand this rather irregular motion for Megi. Examination of NCEP reanalyzed fields indicated that during this period a low-frequency (10-60-day) monsoon gyre in the vicinity of Megi may have interactions with the latter. To understand the effect of the low-frequency mode on the movement of Megi, numerical experiments were designed and conducted. The total flow from the analyzed field is separated into 1) a slowly varying background state, 2) a 10-60-day low frequency component representing the monsoon gyre, and 3) a 10-day high-pass filtered component representing Megi. In the control experiment, the total field containing all three components is used as the initial and lateral boundary conditions, and the WRF model is able to simulate Megi's sharp northward turning successfully. In the second experiment, the 10-60-day mode is removed from the initial and lateral boundary fields. In the absence of the low-frequency mode, Megi moves westward and only slightly northwestward without turning north. When the vortex representing Megi was removed, the movement of the monsoon gyre was also affected. These experiments indicated strong interactions between Megi and the monsoon gyre. The interactions and the way the monsoon gyre actually affected the track of Megi will be discussed in the presentation.

  3. Excimer laser decoating of chromium titanium aluminium nitride to facilitate re-use of cutting tools

    NASA Astrophysics Data System (ADS)

    Sundar, M.; Whitehead, D.; Mativenga, P. T.; Li, L.; Cooke, K. E.

    2009-11-01

    This work reports on the technical feasibility and establishment of a process window for removing chromium titanium aluminium nitride (CrTiAlN) coating from steel substrates by laser irradiation. CrTiAlN coating has high hardness and oxidation resistance, with applications for use with cutting tools. The motivation for removing such coatings is to facilitate re-use of tooling by enabling regrinding or reshaping of a worn tool and hence promote sustainable material usage. In this work, laser decoating was performed using an excimer laser. The effect of laser fluence, number of pulses, frequency, scanning speed and laser beam overlap on the decoating performance was investigated in detail. The minimum threshold laser fluence for removing the CrTiAlN coating was lower than that of the steel substrate and this factor is beneficial in controlling the decoating process. Successful laser removal of CrTiAlN coating without noticeable damage to the steel substrate was demonstrated.

  4. Poor correlation between the removal or deposition of pollen grains and frequency of pollinator contact with sex organs

    NASA Astrophysics Data System (ADS)

    Sakamoto, Ryota L.; Morinaga, Shin-Ichi

    2013-09-01

    Pollinators deposit pollen grains on stigmas and remove pollen grains from anthers. The mechanics of these transfers can now be quantified with the use of high-speed video. We videoed hawkmoths, carpenter bees, and swallowtail butterflies pollinating Clerodendrum trichotomum. The number of grains deposited on stigmas did not vary significantly with the number of times pollinators contacted stigmas. In contrast, pollen removal from the anthers increased significantly with the number of contacts to anthers. Pollen removal varied among the three types of pollinators. Also, the three types carried pollen on different parts of their bodies. In hawkmoths and carpenter bees, a large number of contacted body part with anthers differed significantly from the body part that attached a large number of pollen grains. Our results indicate that a large number of contacts by pollinators does not increase either the male or female reproductive success of plants compared to a small number of contacts during a visit.

  5. Location and removal of deslorelin acetate implants in female African lions (Panthera leo).

    PubMed

    Moresco, Anneke; Dadone, Liza; Arble, Jason; Klaphake, Eric; Agnew, Dalen W

    2014-06-01

    Contraception is necessary to manage zoo animal populations and to be able to house animals in groups without producing additional unwanted offspring. In felids and canids, an association between exposure to progestins and the occurrence of endometrial and mammary gland pathology has been documented. Therefore, the Association of Zoos and Aquariums (AZA) Wildlife Contraceptive Center recommends the use of deslorelin acetate for long-term contraception in carnivores. Return to cyclicity after deslorelin treatment has been variable; some individuals show ovarian suppression for long periods after the expected end of the deslorelin efficacy. In an attempt to reduce the time to reversal, techniques to locate and remove previous implants are being developed. This report documents the successful implementation of high-frequency ultrasonography in lions (Panthera leo) to locate and direct surgical removal of multiple deslorelin implants placed at least 2 yr previously as well as the return of follicular activity in both females at 7 months post-removal of implants.

  6. Study on Gap Flow Field Simulation in Small Hole Machining of Ultrasonic Assisted EDM

    NASA Astrophysics Data System (ADS)

    Liu, Yu; Chang, Hao; Zhang, Wenchao; Ma, Fujian; Sha, Zhihua; Zhang, Shengfang

    2017-12-01

    When machining a small hole with high aspect ratio in EDM, it is hard for the flushing liquid entering the bottom gap and the debris could hardly be removed, which results in the accumulation of debris and affects the machining efficiency and machining accuracy. The assisted ultrasonic vibration can improve the removal of debris in the gap. Based on dynamics simulation software Fluent, a 3D model of debris movement in the gap flow field of EDM small hole machining assisted with side flushing and ultrasonic vibration is established in this paper. When depth to ratio is 3, the laws of different amplitudes and frequencies on debris distribution and removal are quantitatively analysed. The research results show that periodic ultrasonic vibration can promote the movement of debris, which is beneficial to the removal of debris in the machining gap. Compared to traditional small hole machining in EDM, the debris in the machining gap is greatly reduced, which ensures the stability of machining process and improves the machining efficiency.

  7. Integrating the ECG power-line interference removal methods with rule-based system.

    PubMed

    Kumaravel, N; Senthil, A; Sridhar, K S; Nithiyanandam, N

    1995-01-01

    The power-line frequency interference in electrocardiographic signals is eliminated to enhance the signal characteristics for diagnosis. The power-line frequency normally varies +/- 1.5 Hz from its standard value of 50 Hz. In the present work, the performances of the linear FIR filter, Wave digital filter (WDF) and adaptive filter for the power-line frequency variations from 48.5 to 51.5 Hz in steps of 0.5 Hz are studied. The advantage of the LMS adaptive filter in the removal of power-line frequency interference even if the frequency of interference varies by +/- 1.5 Hz from its normal value of 50 Hz over other fixed frequency filters is very well justified. A novel method of integrating rule-based system approach with linear FIR filter and also with Wave digital filter are proposed. The performances of Rule-based FIR filter and Rule-based Wave digital filter are compared with the LMS adaptive filter.

  8. Power Beaming, Orbital Debris Removal, and Other Space Applications of a Ground Based Free Electron Laser

    DTIC Science & Technology

    2010-03-01

    mask of strength, his character, fortitude, and xxii devotion to our family helped to keep me on my feet. What I say with words, he says through...superfluid) and an extremely large heat capacity. This large heat capacity is what makes He II an ideal refrigerant for high power and high frequency...limited tools, ancient astronomers accomplished many insightful discoveries regarding the motion of celestial bodies, but prior to the 1600s, most of

  9. Wind Speed Dependence of Acoustic Ambient Vertical Directional Spectra at High Frequency

    DTIC Science & Technology

    1989-05-26

    the measurements, which is 8 to 32 kHz, is sufficiently high that the propagation is adequately modeled using the Eikonal equation approximation. 4 TD...level spectra were calculated from the resulting time series. Spectral levels at 8, 16, and 32 kHz were recorded in a database along with the wind...indications of biological or industrial contaminations were removed. The resulting database seen here contained 215 samples. 10 * TD 8565 0z 00 a.I. cn

  10. High-Performance Optical Frequency References for Space

    NASA Astrophysics Data System (ADS)

    Schuldt, Thilo; Döringshoff, Klaus; Milke, Alexander; Sanjuan, Josep; Gohlke, Martin; Kovalchuk, Evgeny V.; Gürlebeck, Norman; Peters, Achim; Braxmaier, Claus

    2016-06-01

    A variety of future space missions rely on the availability of high-performance optical clocks with applications in fundamental physics, geoscience, Earth observation and navigation and ranging. Examples are the gravitational wave detector eLISA (evolved Laser Interferometer Space Antenna), the Earth gravity mission NGGM (Next Generation Gravity Mission) and missions, dedicated to tests of Special Relativity, e.g. by performing a Kennedy- Thorndike experiment testing the boost dependence of the speed of light. In this context we developed optical frequency references based on Doppler-free spectroscopy of molecular iodine; compactness and mechanical and thermal stability are main design criteria. With a setup on engineering model (EM) level we demonstrated a frequency stability of about 2·10-14 at an integration time of 1 s and below 6·10-15 at integration times between 100s and 1000s, determined from a beat-note measurement with a cavity stabilized laser where a linear drift was removed from the data. A cavity-based frequency reference with focus on improved long-term frequency stability is currently under development. A specific sixfold thermal shield design based on analytical methods and numerical calculations is presented.

  11. Acoustic emission investigation of cold cracking in gas metal-arc welding of AISI 4340 steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fang, C.K.; Kannatey-Asibu, E. Jr.; Barber, J.R.

    1995-06-01

    Acoustic emission (AE) has been used to investigate the propagation of a finite crack in a weldment subjected to nonuniform longitudinal residual stresses during gas metal arc welding (GMAW). Cold cracking in selected weldments was accelerated using the electrochemical method to cathodically charge the weldments with hydrogen in order to induce hydrogen embrittlement. Cold cracking was observed about 40 min after charging in the specimen subjected to hydrogen embrittlement, while it was observed two days after welding for the one that was left in the atmosphere. The AE signals were generated as the specimen cracked and were recorded, and themore » effects from structure and instrumentation were removed from the measured signals by deconvolution in the frequency domain. Most of the high-amplitude signal components were found to be clustered in the frequency range below 200 kHz. The experimentally obtained spectrum was compared with theoretical results derived in earlier work, and reasonable agreement with theoretical surface displacement in both time and frequency domains was obtained. The envelopes for both spectra were found to decrease with increasing frequency, while the fluctuations in each curve diminished at high frequencies.« less

  12. Bias correction in the realized stochastic volatility model for daily volatility on the Tokyo Stock Exchange

    NASA Astrophysics Data System (ADS)

    Takaishi, Tetsuya

    2018-06-01

    The realized stochastic volatility model has been introduced to estimate more accurate volatility by using both daily returns and realized volatility. The main advantage of the model is that no special bias-correction factor for the realized volatility is required a priori. Instead, the model introduces a bias-correction parameter responsible for the bias hidden in realized volatility. We empirically investigate the bias-correction parameter for realized volatilities calculated at various sampling frequencies for six stocks on the Tokyo Stock Exchange, and then show that the dynamic behavior of the bias-correction parameter as a function of sampling frequency is qualitatively similar to that of the Hansen-Lunde bias-correction factor although their values are substantially different. Under the stochastic diffusion assumption of the return dynamics, we investigate the accuracy of estimated volatilities by examining the standardized returns. We find that while the moments of the standardized returns from low-frequency realized volatilities are consistent with the expectation from the Gaussian variables, the deviation from the expectation becomes considerably large at high frequencies. This indicates that the realized stochastic volatility model itself cannot completely remove bias at high frequencies.

  13. Occurrence and fate of the herbicide glyphosate and its degradate aminomethylphosphonic acid in the atmosphere

    USGS Publications Warehouse

    Chang, Feng-Chih; Simcik, M.F.; Capel, P.D.

    2011-01-01

    This is the first report on the ambient levels of glyphosate, the most widely used herbicide in the United States, and its major degradation product, aminomethylphosphonic acid (AMPA), in air and rain. Concurrent, weekly integrated air particle and rain samples were collected during two growing seasons in agricultural areas in Mississippi and Iowa. Rain was also collected in Indiana in a preliminary phase of the study. The frequency of glyphosate detection ranged from 60 to 100% in both air and rain. The concentrations of glyphosate ranged from 3 and from <0.1 to 2.5 µg/L in air and rain samples, respectively. The frequency of detection and median and maximum concentrations of glyphosate in air were similar or greater to those of the other high-use herbicides observed in the Mississippi River basin, whereas its concentration in rain was greater than the other herbicides. It is not known what percentage of the applied glyphosate is introduced into the air, but it was estimated that up to 0.7% of application is removed from the air in rainfall. Glyphosate is efficiently removed from the air; it is estimated that an average of 97% of the glyphosate in the air is removed by a weekly rainfall ≥30 mm.

  14. Metamaterial and Metastructural Architectures for Novel C4ISR Devices and Sensors

    DTIC Science & Technology

    2015-03-01

    2.7 The SEM pictures of the fabricated metastructure cage waveguide a) before and b) after the thermal oxidization and HF etching process ..10 Fig...of the hollow core. (Bottom) The SiO2 shell in the core was removed by buffered high-frequency etch...28 Fig. 3.9 SEM images of the waveguides after etching in CR-9 and buffered oxide etchant

  15. Light and scanning electron microscope investigations comparing calculus removal using an Er:YAG laser and a frequency-doubled alexandrite laser

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas; Sadegh, Hamid M. M.; Goldin, Dan S.

    1997-05-01

    With respect to lasers emitting within the mid-IR spectral domain fiber applicators are being developed. Intended is the use of these lasers in periodontal therapy and their application inside the gingival pocket. Aim of the study presented here is to compare the effect of an Er:YAG laser on dental calculus with the results following irradiation with a frequency doubled Alexandrite laser. The surface of freshly extracted wisdom teeth and of extracted teeth suffering from severe periodontitis were irradiated with both laser wavelengths using a standardized application protocol. Calculus on the enamel surface, at the enamel cementum junction and on the root surface was irradiated. For light microscope investigations undecalcified histological sections were prepared after treatment. For the scanning electron microscope teeth were dried in alcohol and sputtered with gold. Investigations revealed that with both laser systems calculus can be removed. Using the frequency doubled Alexandrite laser selective removal of calculus is possible while engaging the Er:YAG laser even at lowest energies necessary for calculus removal healthy cementum is ablated without control.

  16. Component isolation for multi-component signal analysis using a non-parametric gaussian latent feature model

    NASA Astrophysics Data System (ADS)

    Yang, Yang; Peng, Zhike; Dong, Xingjian; Zhang, Wenming; Clifton, David A.

    2018-03-01

    A challenge in analysing non-stationary multi-component signals is to isolate nonlinearly time-varying signals especially when they are overlapped in time and frequency plane. In this paper, a framework integrating time-frequency analysis-based demodulation and a non-parametric Gaussian latent feature model is proposed to isolate and recover components of such signals. The former aims to remove high-order frequency modulation (FM) such that the latter is able to infer demodulated components while simultaneously discovering the number of the target components. The proposed method is effective in isolating multiple components that have the same FM behavior. In addition, the results show that the proposed method is superior to generalised demodulation with singular-value decomposition-based method, parametric time-frequency analysis with filter-based method and empirical model decomposition base method, in recovering the amplitude and phase of superimposed components.

  17. 47 CFR 74.637 - Emissions and emission limitations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...

  18. 47 CFR 74.637 - Emissions and emission limitations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...

  19. 47 CFR 74.637 - Emissions and emission limitations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...

  20. 47 CFR 74.637 - Emissions and emission limitations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...

  1. 47 CFR 74.637 - Emissions and emission limitations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vestigial sideband AM video: On any frequency removed from the center frequency of the authorized band by... communications. Frequency Band (MHz) Maximum authorized bandwidth (MHz) 1,990 to 2,110 18 6,425 to 6,525 25 6,875...

  2. Characterization of irradiated AISI 316L stainless steel disks removed from the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vevera, Bradley J; Hyres, James W; McClintock, David A

    2014-01-01

    Irradiated AISI 316L stainless steel disks were removed from the Spallation Neutron Source (SNS) for post-irradiation examination (PIE) to assess mechanical property changes due to radiation damage and erosion of the target vessel. Topics reviewed include high-resolution photography of the disk specimens, cleaning to remove mercury (Hg) residue and surface oxides, profile mapping of cavitation pits using high frequency ultrasonic testing (UT), high-resolution surface replication, and machining of test specimens using wire electrical discharge machining (EDM), tensile testing, Rockwell Superficial hardness testing, Vickers microhardness testing, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The effectiveness of the cleaning proceduremore » was evident in the pre- and post-cleaning photography and permitted accurate placement of the test specimens on the disks. Due to the limited amount of material available and the unique geometry of the disks, machine fixturing and test specimen design were critical aspects of this work. Multiple designs were considered and refined during mock-up test runs on unirradiated disks. The techniques used to successfully machine and test the various specimens will be presented along with a summary of important findings from the laboratory examinations.« less

  3. Differentiation of specific ripple patterns helps to identify epileptogenic areas for surgical procedures.

    PubMed

    Kerber, Karolin; Dümpelmann, Matthias; Schelter, Björn; Le Van, Pierre; Korinthenberg, Rudolf; Schulze-Bonhage, Andreas; Jacobs, Julia

    2014-07-01

    High frequency oscillations (HFOs) at 80-500 Hz are promising markers of epileptic areas. Several retrospective studies reported that surgical removal of areas generating HFOs was associated with a good seizure outcome. Recent reports suggested that ripple (80-200 Hz) HFO patterns co-existed with different background EEG activities. We hypothesized that the coexisting background EEG pattern may distinguish physiological from epileptic ripples. Rates of HFOs were analyzed in intracranial EEG recordings of 22 patients. Additionally, ripple patterns were classified for each channel depending either as coexisting with a flat or oscillatory background activity. A multi-variate analysis was performed to determine whether removal of areas showing the above EEG markers correlated with seizure outcome. Removal of areas generating high rates of 'fast ripples (>200 Hz)' and 'ripples on a flat background activity' showed a significant correlation with a seizure-free outcome. In contrast, removal of high rates of 'ripples' or 'ripple patterns in a continuously oscillating background' was not significantly associated with seizure outcome. Ripples occurring in an oscillatory background activity may be suggestive of physiological activity, while those on a flat background reflect epileptic activity. Consideration of coexisting background patterns may improve the delineation of the epileptogenic areas using ripple oscillations. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  4. High power water load for microwave and millimeter-wave radio frequency sources

    DOEpatents

    Ives, R. Lawrence; Mizuhara, Yosuke M.; Schumacher, Richard V.; Pendleton, Rand P.

    1999-01-01

    A high power water load for microwave and millimeter wave radio frequency sources has a front wall including an input port for the application of RF power, a cylindrical dissipation cavity lined with a dissipating material having a thickness which varies with depth, and a rear wall including a rotating reflector for the reflection of wave energy inside the cylindrical cavity. The dissipation cavity includes a water jacket for removal of heat generated by the absorptive material coating the dissipation cavity, and this absorptive material has a thickness which is greater near the front wall than near the rear wall. Waves entering the cavity reflect from the rotating reflector, impinging and reflecting multiple times on the absorptive coating of the dissipation cavity, dissipating equal amounts of power on each internal reflection.

  5. Skin effect mitigation in laser processed multi-walled carbon nanotube/copper conductors

    NASA Astrophysics Data System (ADS)

    Keramatnejad, K.; Zhou, Y. S.; Gao, Y.; Rabiee Golgir, H.; Wang, M.; Jiang, L.; Silvain, J.-F.; Lu, Y. F.

    2015-10-01

    In this study, laser-processed multi-walled carbon nanotube (MWCNT)/Cu conductors are introduced as potential passive components to mitigate the skin effect of Cu at high frequencies (0-10 MHz). Suppressed skin effect is observed in the MWCNT/Cu conductors compared to primitive Cu. At an AC frequency of 10 MHz, a maximum AC resistance reduction of 94% was observed in a MWCNT/Cu conductor after being irradiated at a laser power density of 189 W/cm2. The reduced skin effect in the MWCNT/Cu conductors is ascribed to the presence of MWCNT channels which are insensitive to AC frequencies. The laser irradiation process is observed to play a crucial role in reducing contact resistance at the MWCNT-Cu interfaces, removing impurities in MWCNTs, and densifying MWCNT films.

  6. A wideband, high-resolution spectrum analyzer

    NASA Technical Reports Server (NTRS)

    Quirk, M. P.; Wilck, H. C.; Garyantes, M. F.; Grimm, M. J.

    1988-01-01

    A two-million-channel, 40 MHz bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory is described. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2 (sup 21) point Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple signal detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis.

  7. A wide-band high-resolution spectrum analyzer

    NASA Technical Reports Server (NTRS)

    Quirk, Maureen P.; Garyantes, Michael F.; Wilck, Helmut C.; Grimm, Michael J.

    1988-01-01

    A two-million-channel, 40 MHz bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory is described. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2 (sup 21) point Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis.

  8. Oscillation effects upon film boiling from a sphere.

    NASA Technical Reports Server (NTRS)

    Schmidt, W. E.; Witte, L. C.

    1972-01-01

    Heat transfer rates from a silver-plated copper sphere, 0.75 in. in diameter, were studied by high speed photography during oscillations of the sphere in saturated liquid nitrogen and Freon-11. The oscillation frequencies ranged from zero to 13 Hz, and the amplitude-to-diameter ratio varied from zero to 2.67. The sphere was supported by a thin-walled stainless steel tube and carried a thermocouple attached near the lower stagnation point. A Fastax WF-3 16mm movie camera was used at about 2000 frames/sec. The differences in the vapor removal process at lower and higher oscillation frequencies are discussed.

  9. A wide-band high-resolution spectrum analyzer.

    PubMed

    Quirk, M P; Garyantes, M F; Wilck, H C; Grimm, M J

    1988-12-01

    This paper describes a two-million-channel 40-MHz-bandwidth, digital spectrum analyzer under development at the Jet Propulsion Laboratory. The analyzer system will serve as a prototype processor for the sky survey portion of NASA's Search for Extraterrestrial Intelligence program and for other applications in the Deep Space Network. The analyzer digitizes an analog input, performs a 2(21)-point, Discrete Fourier Transform, accumulates the output power, normalizes the output to remove frequency-dependent gain, and automates simple signal detection algorithms. Due to its built-in frequency-domain processing functions and configuration flexibility, the analyzer is a very powerful tool for real-time signal analysis and detection.

  10. Alternating Field Electronanofluidization

    NASA Astrophysics Data System (ADS)

    Espin, M. J.; Valverde, J. M.; Quintanilla, M. A. S.; Castellanos, A.

    2009-06-01

    The use of fluidized beds to remove submicron particles from gases has been investigated since 1949. High efficiency removal was achieved in the 1970's by imposing an electric field on a fluidized bed of semi-insulating granules that were able to collect the charged pollutant entrained in the fluidizing gas. In spite of their extended use nowadays, the collection efficiency of electrofluidized beds (EFB) is still hindered by gas bypassing associated to gas bubbling and the consequent requirement of too high gas flow and pressure drop. In this paper we report on the electromechanical behavior of an EFB of insulating nanoparticles. When fluidized by gas, these nanoparticles form extremely porous light agglomerates of size of the order of hundreds of microns that allow for a highly expanded nonbubbling fluidized state at reduced gas flow. It is found that fluidization uniformity and bed expansion are additionally enhanced by an imposed AC electric field for field oscillation frequencies of several tens of hertzs and field strengths of the order of 1 kV/cm. For oscillation frequencies of the order of hertzs, or smaller, bed expansion is hindered due to electrophoretic deposition of the agglomerates onto the vessel walls, whereas for oscillation frequencies of the order of kilohertzs, or larger, electrophoresis is nullified and bed expansion is not affected. According to a proposed model, the size of nanoparticle agglomerates stems from the balance between shear, which depends on field strength, and van der Waals forces. The optimum field strength for enhancing bed expansion produces an electric force on the agglomerates similar to their weight force, while the oscillation velocity of the agglomerates is similar to the gas velocity.

  11. The 1994 Northridge, California, earthquake: Investigation of rupture velocity, risetime, and high-frequency radiation

    USGS Publications Warehouse

    Hartzell, S.; Liu, P.; Mendoza, C.

    1996-01-01

    A hybrid global search algorithm is used to solve the nonlinear problem of calculating slip amplitude, rake, risetime, and rupture time on a finite fault. Thirty-five strong motion velocity records are inverted by this method over the frequency band from 0.1 to 1.0 Hz for the Northridge earthquake. Four regions of larger-amplitude slip are identified: one near the hypocenter at a depth of 17 km, a second west of the hypocenter at about the same depth, a third updip from the hypocenter at a depth of 10 km, and a fourth updip from the hypocenter and to the northwest. The results further show an initial fast rupture with a velocity of 2.8 to 3.0 km/s followed by a slow termination of the rupture with velocities of 2.0 to 2.5 km/s. The initial energetic rupture phase lasts for 3 s, extending out 10 km from the hypocenter. Slip near the hypocenter has a short risetime of 0.5 s, which increases to 1.5 s for the major slip areas removed from the hypocentral region. The energetic rupture phase is also shown to be the primary source of high-frequency radiation (1-15 Hz) by an inversion of acceleration envelopes. The same global search algorithm is used in the envelope inversion to calculate high-frequency radiation intensity on the fault and rupture time. The rupture timing from the low- and high-frequency inversions is similar, indicating that the high frequencies are produced primarily at the mainshock rupture front. Two major sources of high-frequency radiation are identified within the energetic rupture phase, one at the hypocenter and another deep source to the west of the hypocenter. The source at the hypocenter is associated with the initiation of rupture and the breaking of a high-stress-drop asperity and the second is associated with stopping of the rupture in a westerly direction.

  12. SITE TECHNOLOGY CAPSULE: IITRI RADIO FREQUENCY HEATING TECHNOLOGY

    EPA Science Inventory

    Radio frequency heating (RFH) technologies use electromagnetic energy in the radio frequency i(RF) band to heat soil in-situ, thereby potentially enhancing the performances of standard soil vapor extraction (SVE) technologies. ontaminants are removed from in situ soils and transf...

  13. SITE TECHNOLOGY CAPSULE: IITRI RADIO FREQUENCY HEATING TECHNOLOGY

    EPA Science Inventory

    Radio frequency heating (RFH) technologies use electromagnetic energy in the radio frequency (RF) band to heat soil in situ, thereby potentially enhancing the performance of standard soil vapor extraction (SVE) technologies. Contaminants are removed from in situ soils and transfe...

  14. High capacitance density MIS capacitor using Si nanowires by MACE and ALD alumina dielectric

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leontis, I.; Nassiopoulou, A. G., E-mail: A.Nassiopoulou@inn.demokritos.gr; Botzakaki, M. A.

    2016-06-28

    High capacitance density three-dimensional (3D) metal-insulator-semiconductor (MIS) capacitors using Si nanowires (SiNWs) by metal-assisted chemical etching and atomic-layer-deposited alumina dielectric film were fabricated and electrically characterized. A chemical treatment was used to remove structural defects from the nanowire surface, in order to reduce the density of interface traps at the Al{sub 2}O{sub 3}/SiNW interface. SiNWs with two different lengths, namely, 1.3 μm and 2.4 μm, were studied. A four-fold capacitance density increase compared to a planar reference capacitor was achieved with the 1.3 μm SiNWs. In the case of the 2.4 μm SiNWs this increase was ×7, reaching a value of 4.1 μF/cm{sup 2}. Capacitance-voltagemore » (C-V) measurements revealed that, following a two-cycle chemical treatment, frequency dispersion at accumulation regime and flat-band voltage shift disappeared in the case of the 1.3 μm SiNWs, which is indicative of effective removal of structural defects at the SiNW surface. In the case of the 2.4 μm SiNWs, frequency dispersion at accumulation persisted even after the two-step chemical treatment. This is attributed to a porous Si layer at the SiNW tops, which is not effectively removed by the chemical treatment. The electrical losses of MIS capacitors in both cases of SiNW lengths were studied and will be discussed.« less

  15. Biomechanical evaluation of dental implants with three different designs: Removal torque and resonance frequency analysis in rabbits.

    PubMed

    Gehrke, Sergio Alexandre; Marin, Giovanni Wiel

    2015-05-01

    The objective of this study was to investigate the effect of implant design on stability and resistance to reverse torque in the tibia of rabbits. Three test groups were prepared using the different characteristics of each implant model: square threads with progressive depth to the apex, a cervical portion without threads and a self-tapping system that is quite pronounced and aggressive (Group 1); triangular threads with flat tips with increasing thread depth from the cervical portion to the apex and a small self-tapping portion with a short thread pitch (Group 2); long thread pitch, progressive thread depth, an apical area with a small self-tapping portion (Group 3). For the two last groups, a final single-use drill was provided for each implant. Nine rabbits received 54 conical implants with a same surface treatment. The resonance frequency was analysed four times (0, 6, 8 and 12 weeks), and removal torque values were measured at three time intervals after the implantations (6, 8 and 12 weeks). In comparing the implant stability quotient at the four time points, highly significant statistic differences were found (p = 1.29(-10)). The reverse torque at the three time points was also significantly different among the groups (p = 0.00015). The implants of Group 2, with seemingly less aggressive design, more quickly reached high values of stability and removal torque. Under the limitations of this study, however, it is possible that in cases in which there may be low osseointegration response, the implant design should be evaluated. Copyright © 2014 Elsevier GmbH. All rights reserved.

  16. Vascular access infection: survival or mortality.

    PubMed

    Hirotani, Sachiko; Kai, Kotaro; Iwatoh, Kazuhiro; Sannomiya, Akihito; Nakajima, Ichiro; Fuchinoue, Shohei

    2015-11-01

    We conducted an analysis on 11 cases of death after AVG infection that occurred between 1996 and 2013, and compared their information with those of 23 cases of generalized infection due to arteriovenous graft (AVG) infection during the same period who survived. The cause of death was sepsis in all 11 patients. The initial C-reactive protein (CRP) was 10.2-39.8 (28 in average) and the duration from onset of fever to vascular access (VA) hemostasis/removal procedure was 6-9 days (6.4 days in average) in the 11 cases of death. Blood culture revealed a high frequency of methicillin-resistant staphylococcus aureus (MRSA) in 7 of the 11 cases of death. In contrast, in 23 survivors with VA infection and generalized infection, the CRP at the initial visit was 3.2-15.8 (5.6 in average) and the duration from onset of the fever to VA hemostasis/removal procedure was 0-5 days (2.6 days in average), and blood culture revealed a high frequency of methicillin-sensitive staphylococcus aureus (MSSA). Among the cases of death, although VA infection in the upper extremity itself resolved after removing the artificial vessel, they died without an improvement of sepsis. The reason why the sepsis did not resolve is that infectious foci were secondarily formed in other areas than the upper extremity because the start of treatment for VA infection was delayed. Treatment for VA infection should be started as early as possible after onset to avoid the formation of secondary infectious foci in other areas.

  17. Thermal emittance enhancement of graphite-copper composites for high temperature space based radiators

    NASA Technical Reports Server (NTRS)

    Rutledge, Sharon K.; Forkapa, Mark J.; Cooper, Jill M.

    1991-01-01

    Graphite-copper composites are candidate materials for space based radiators. The thermal emittance of this material, however, is a factor of two lower than the desired emittance for these systems of greater than or equal to 0.85. Arc texturing was investigated as a surface modification technique for enhancing the emittance of the composite. Since the outer surface of the composite is copper, and samples of the composite could not be readily obtained for testing, copper was used for optimization testing. Samples were exposed to various frequencies and currents of arcs during texturing. Emittances near the desired goal were achieved at frequencies less than 500 Hz. Arc current did not appear to play a major role under 15 amps. Particulate carbon was observed on the surface, and was easily removed by vibration and handling. In order to determine morphology adherence, ultrasonic cleaning was used to remove the loosely adherent material. This reduced the emittance significantly. Emittance was found to increase with increasing frequency for the cleaned samples up to 500 Hz. The highest emittance achieved on these samples over the temperature range of interest was 0.5 to 0.6, which is approximately a factor of 25 increase over the untextured copper emittance.

  18. Electro-optic modulator based gate transient suppression for sine-wave gated InGaAs/InP single photon avalanche photodiode

    NASA Astrophysics Data System (ADS)

    Zhang, Yixin; Zhang, Xuping; Shi, Yuanlei; Ying, Zhoufeng; Wang, Shun

    2014-06-01

    Capacitive gate transient noise has been problematic for the high-speed single photon avalanche photodiode (SPAD), especially when the operating frequency extends to the gigahertz level. We proposed an electro-optic modulator based gate transient noise suppression method for sine-wave gated InGaAs/InP SPAD. With the modulator, gate transient is up-converted to its higher-order harmonics that can be easily removed by low pass filtering. The proposed method enables online tuning of the operating rate without modification of the hardware setup. At 250 K, detection efficiency of 14.7% was obtained with 4.8×10-6 per gate dark count and 3.6% after-pulse probabilities for 1550-nm optical signal under 1-GHz gating frequency. Experimental results have shown that the performance of the detector can be maintained within a designated frequency range from 0.97 to 1.03 GHz, which is quite suitable for practical high-speed SPAD applications operated around the gigahertz level.

  19. High-resolution imaging of SNR IC443 and W44 with the Sardinia Radio Telescope

    NASA Astrophysics Data System (ADS)

    Egron, E.; Pellizzoni, A.; Iacolina, M. N.; Loru, S.; Marongiu, M.; Righini, S.; Cardillo, M.; Giuliani, A.; Mulas, S.; Murtas, G.; Simeone, D.

    2017-02-01

    We present single-dish imaging of the well-known Supernova Remnants (SNRs) IC443 and W44 at 1.5 GHz and 7 GHz with the recently commissioned 64-m diameter Sardinia Radio Telescope (SRT). Our images were obtained through on-the-fly mapping techniques, providing antenna beam oversampling, automatic baseline subtraction and radio-frequency interference removal. It results in high-quality maps of the SNRs at 7 GHz, which are usually lacking and not easily achievable through interferometry at this frequency due to the very large SNR structures. SRT continuum maps of our targets are consistent with VLA maps carried out at lower frequencies (at 324 MHz and 1.4 GHz), providing a view of the complex filamentary morphology. New estimates of the total flux density are given within 3% and 5% error at 1.5 GHz and 7 GHz respectively, in addition to flux measurements in different regions of the SNRs.

  20. Removal of ring artifacts in microtomography by characterization of scintillator variations.

    PubMed

    Vågberg, William; Larsson, Jakob C; Hertz, Hans M

    2017-09-18

    Ring artifacts reduce image quality in tomography, and arise from faulty detector calibration. In microtomography, we have identified that ring artifacts can arise due to high-spatial frequency variations in the scintillator thickness. Such variations are normally removed by a flat-field correction. However, as the spectrum changes, e.g. due to beam hardening, the detector response varies non-uniformly introducing ring artifacts that persist after flat-field correction. In this paper, we present a method to correct for ring artifacts from variations in scintillator thickness by using a simple method to characterize the local scintillator response. The method addresses the actual physical cause of the ring artifacts, in contrary to many other ring artifact removal methods which rely only on image post-processing. By applying the technique to an experimental phantom tomography, we show that ring artifacts are strongly reduced compared to only making a flat-field correction.

  1. Optimization of an integrated sponge--granular activated carbon fluidized bed bioreactor as pretreatment to microfiltration in wastewater reuse.

    PubMed

    Xing, W; Ngo, H H; Guo, W S; Listowski, A; Cullum, P

    2012-06-01

    A specific integrated fluidized bed bioreactor (iFBBR) was optimized in terms of organic loading rate (OLR), hydraulic retention time (HRT) and frequency of new sustainable flocculant (NSBF) addition for primary treated sewage effluent (PTSE) treatment. It was observed that iFBBR achieved the best performance with the operating conditions of 4 times/day NSBF addition, HRT of 90 min and OLR of 8.64 kg COD/day m(3). The removal efficiencies were found to be more than 93% of dissolved organic carbon (DOC), 61% of total nitrogen (T-N) and 60% of total phosphorus (T-P). iFBBR as pretreatment of submerged microfiltration (SMF) is successful in increasing the critical flux and reducing the membrane fouling. NSBF-iFBBR-SMF hybrid system led to very high organic removal efficiency with an average DOC removal of 97% from synthetic PTSE. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. High field Q slope and the effect of low-temperature baking at 3 GHz

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ciovati, G.; Eremeev, G.; Hannon, F.

    Here, a strong degradation of the unloaded quality factor with field, called high field Q-slope, is commonly observed above Bmore » $$_{p}$$ $$\\cong$$ 100 mT in elliptical superconducting niobium cavities at 1.3 GHz and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above B$$_{p}$$ $$\\cong$$100 mT. The measurements show that a high field Q-slope phenomenon limits the field reach at this frequency, that the high field Q-slope onset field depends weakly on the frequency, and that the high field Q-slope can be removed by the typical empirical solution of electropolishing followed by heating to 120 $$^{\\circ}$$C for 48 hrs. In addition, one of the cavities reached a quench field of 174~mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.« less

  3. High field Q slope and the effect of low-temperature baking at 3 GHz

    DOE PAGES

    Ciovati, G.; Eremeev, G.; Hannon, F.

    2018-01-29

    Here, a strong degradation of the unloaded quality factor with field, called high field Q-slope, is commonly observed above Bmore » $$_{p}$$ $$\\cong$$ 100 mT in elliptical superconducting niobium cavities at 1.3 GHz and 1.5 GHz. In the present experiments several 3 GHz niobium cavities were measured up to and above B$$_{p}$$ $$\\cong$$100 mT. The measurements show that a high field Q-slope phenomenon limits the field reach at this frequency, that the high field Q-slope onset field depends weakly on the frequency, and that the high field Q-slope can be removed by the typical empirical solution of electropolishing followed by heating to 120 $$^{\\circ}$$C for 48 hrs. In addition, one of the cavities reached a quench field of 174~mT and its field dependence of the quality factor was compared against global heating predicted by a thermal feedback model.« less

  4. 47 CFR 87.139 - Emission limitations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in the frequency bands 1435-1535 MHz and 2310-2390 MHz or digital modulation (G7D) for differential... 1435-1535 MHz band, when the frequency is removed from the assigned frequency by more than 250 percent... telemetry or telecommand in the 1435-1535 MHz and 2310-2390 MHz frequency bands with an authorized bandwidth...

  5. Quantitative Reevaluation of the Effects of Short- and Long-Term Removal of Descending Modulatory Inputs on the Pyloric Rhythm of the Crab, Cancer borealis1,2,3

    PubMed Central

    Hamood, Albert W.; Haddad, Sara A.; Otopalik, Adriane G.; Rosenbaum, Philipp

    2015-01-01

    Abstract The crustacean stomatogastric ganglion (STG) receives descending neuromodulatory inputs from three anterior ganglia: the paired commissural ganglia (CoGs), and the single esophageal ganglion (OG). In this paper, we provide the first detailed and quantitative analyses of the short- and long-term effects of removal of these descending inputs (decentralization) on the pyloric rhythm of the STG. Thirty minutes after decentralization, the mean frequency of the pyloric rhythm dropped from 1.20 Hz in control to 0.52 Hz. Whereas the relative phase of pyloric neuron activity was approximately constant across frequency in the controls, after decentralization this changed markedly. Nine control preparations kept for 5–6 d in vitro maintained pyloric rhythm frequencies close to their initial values. Nineteen decentralized preparations kept for 5–6 d dropped slightly in frequency from those seen at 30 min following decentralization, but then displayed stable activity over 6 d. Bouts of higher frequency activity were intermittently seen in both control and decentralized preparations, but the bouts began earlier and were more frequent in the decentralized preparations. Although the bouts may indicate that the removal of the modulatory inputs triggered changes in neuronal excitability, these changes did not produce obvious long-lasting changes in the frequency of the decentralized preparations. PMID:25914899

  6. IN SITU AND SOIL DECONTAMINATION BY RADIO FREQUENCY HEATING

    EPA Science Inventory

    In situ radio frequency heating is performed by applying electromagnetic energy in the radio frequency band to an array of electrodes placed in bore holes drilled through the contaminated soil. he process removes organic contaminants from large volumes of soil by volatilization, ...

  7. 21 CFR 878.5360 - Tweezer-type epilator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... (a) Identification. The tweezer-type epilator is an electrical device intended to remove hair. The energy provided at the tip of the tweezer used to remove hair may be radio frequency, galvanic (direct...

  8. 21 CFR 878.5360 - Tweezer-type epilator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (a) Identification. The tweezer-type epilator is an electrical device intended to remove hair. The energy provided at the tip of the tweezer used to remove hair may be radio frequency, galvanic (direct...

  9. 21 CFR 878.5360 - Tweezer-type epilator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... (a) Identification. The tweezer-type epilator is an electrical device intended to remove hair. The energy provided at the tip of the tweezer used to remove hair may be radio frequency, galvanic (direct...

  10. 21 CFR 878.5360 - Tweezer-type epilator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... (a) Identification. The tweezer-type epilator is an electrical device intended to remove hair. The energy provided at the tip of the tweezer used to remove hair may be radio frequency, galvanic (direct...

  11. 21 CFR 878.5360 - Tweezer-type epilator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... (a) Identification. The tweezer-type epilator is an electrical device intended to remove hair. The energy provided at the tip of the tweezer used to remove hair may be radio frequency, galvanic (direct...

  12. 78 FR 49762 - Desecheo National Wildlife Refuge, PR; Final Comprehensive Conservation Plan and Finding of No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-15

    ... complete the removal of all invasive animal species. We will also develop and implement a plan for..., if necessary, efforts to remove invasive species. The number of vegetation plots and frequency of... safety of the refuge regarding the removal of unexploded ordnance. CCP Alternatives, Including Our...

  13. Automated segmentation of linear time-frequency representations of marine-mammal sounds.

    PubMed

    Dadouchi, Florian; Gervaise, Cedric; Ioana, Cornel; Huillery, Julien; Mars, Jérôme I

    2013-09-01

    Many marine mammals produce highly nonlinear frequency modulations. Determining the time-frequency support of these sounds offers various applications, which include recognition, localization, and density estimation. This study introduces a low parameterized automated spectrogram segmentation method that is based on a theoretical probabilistic framework. In the first step, the background noise in the spectrogram is fitted with a Chi-squared distribution and thresholded using a Neyman-Pearson approach. In the second step, the number of false detections in time-frequency regions is modeled as a binomial distribution, and then through a Neyman-Pearson strategy, the time-frequency bins are gathered into regions of interest. The proposed method is validated on real data of large sequences of whistles from common dolphins, collected in the Bay of Biscay (France). The proposed method is also compared with two alternative approaches: the first is smoothing and thresholding of the spectrogram; the second is thresholding of the spectrogram followed by the use of morphological operators to gather the time-frequency bins and to remove false positives. This method is shown to increase the probability of detection for the same probability of false alarms.

  14. A wide-band, high-resolution spectrum analyzer

    NASA Technical Reports Server (NTRS)

    Wilck, H. C.; Quirk, M. P.; Grimm, M. J.

    1985-01-01

    A million-channel, 20 MHz-bandwidth, digital spectrum analyzer under evelopment for use in the SETI Sky Survey and other applications in the Deep Space Network is described. The analyzer digitizes an analog input, performs a 2(20)-point Radix-2, Fast Fourier Transform, accumulates the output power, and normalizes the output to remove frequency-dependent gain. The effective speed of the real-time hardware is 2.2 GigaFLOPS.

  15. Use of the piezosurgery technique for cutting bones in the autotransplantation of unerupted third molars.

    PubMed

    Koszowski, Rafał; Morawiec, Tadeusz; Bubiłek-Bogacz, Anna

    2013-01-01

    Autotransplantation is a well-known method used in oral surgery. However, risk of failure, most commonly resulting from root resorption of the transplanted tooth or ankylosis, is quite high. Piezosurgery with specific device tip vibration frequencies enables selective tissue cutting, and therefore, tooth buds or teeth can easily be removed from bones with little injury to periodontal fibers or bud follicles.

  16. Use of a genetic algorithm for the analysis of eye movements from the linear vestibulo-ocular reflex

    NASA Technical Reports Server (NTRS)

    Shelhamer, M.

    2001-01-01

    It is common in vestibular and oculomotor testing to use a single-frequency (sine) or combination of frequencies [sum-of-sines (SOS)] stimulus for head or target motion. The resulting eye movements typically contain a smooth tracking component, which follows the stimulus, in which are interspersed rapid eye movements (saccades or fast phases). The parameters of the smooth tracking--the amplitude and phase of each component frequency--are of interest; many methods have been devised that attempt to identify and remove the fast eye movements from the smooth. We describe a new approach to this problem, tailored to both single-frequency and sum-of-sines stimulation of the human linear vestibulo-ocular reflex. An approximate derivative is used to identify fast movements, which are then omitted from further analysis. The remaining points form a series of smooth tracking segments. A genetic algorithm is used to fit these segments together to form a smooth (but disconnected) wave form, by iteratively removing biases due to the missing fast phases. A genetic algorithm is an iterative optimization procedure; it provides a basis for extending this approach to more complex stimulus-response situations. In the SOS case, the genetic algorithm estimates the amplitude and phase values of the component frequencies as well as removing biases.

  17. Clinical results from first use of prostate stent as fiducial for radiotherapy of prostate cancer.

    PubMed

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Larsen, Erik Hoejkjaer; Fabrin, Knud; Fisker, Rune V

    2011-05-01

    A clinical feasibility study using a removable prostate stent as fiducial for image-guided radiotherapy (IGRT) of localized prostate cancer (PC). The study included patients with local or locally advanced PC. The clinical target volume (CTV) was outlined on magnetic resonance (MR) images co-registered to planning computer tomography (CT) images. Daily online IGRT was delivered using the stent as fiducial. Risk of migration was estimated using multiple MR. Acute urinary toxicity was scored using the international prostate symptom score (IPSS). Late gastro-intestinal (GI) and genito-urinary (GU) toxicity was scored using the Radio Therapy Oncology Group (RTOG) score, biochemical failure (BF) was defined as an elevation of prostate specific antigen (PSA) above nadir plus 2 ng/ml after radiotherapy. One hundred men were enrolled in the study. Ninety completed radiotherapy with the stent as fiducial. No migration of the stent was seen, but three cases of dislocation of the stent to the bladder were observed. Acute urinary toxicity based on IPSS was comparable to toxicity in patients who had gold markers (GM) as fiducials. Removal of the stent was associated with a high frequency of urinary retention. Late GI and GU toxicity and BF were comparable to those of other studies, but longer observation time is needed. This study reports the first clinical results of using a prostate stent as fiducial. No migration of the stent observed. Dislocation of the stent to the urinary bladder was observed in three cases, requiring removal of the stent and insertion of a new fiducial. Acute toxicity during radiotherapy evaluated from IPSS was comparable to toxicity in patients with GM. Removal of the stent was associated with a high frequency of post procedural urinary retention. Late toxicity and BF were comparable to those of other studies, though longer observation time is needed.

  18. Investigation into the optimum beam shape and fluence for selective ablation of dental calculus at lambda = 400 nm.

    PubMed

    Schoenly, Joshua E; Seka, Wolf; Rechmann, Peter

    2010-01-01

    A frequency-doubled Ti:sapphire laser is shown to selectively ablate dental calculus. The optimal transverse shape of the laser beam, including its variability under water-cooling, is determined for selective ablation of dental calculus. Intensity profiles under various water-cooling conditions were optically observed. The 400-nm laser was coupled into a multimode optical fiber using an f = 2.5-cm lens and light-shaping diffuser. Water-cooling was supplied coaxially around the fiber. Five human tooth samples (four with calculus and one pristine) were irradiated perpendicular to the tooth surface while the tooth was moved back and forth at 0.3 mm/second, varying between 20 and 180 iterations. The teeth were imaged before and after irradiation using light microscopy with a flashing blue light-emitting diode (LED). An environmental scanning electron microscope imaged each tooth after irradiation. High-order super-Gaussian intensity profiles are observed at the output of a fiber coiled around a 4-in. diameter drum. Super-Gaussian beams have a more-homogenous fluence distribution than Gaussian beams and have a higher energy efficiency for selective ablation. Coaxial water-cooling does not noticeably distort the intensity distribution within 1 mm from the optical fiber. In contrast, lasers focused to a Gaussian cross section (< or =50-microm diameter) without fiber propagation and cooled by a water spray are heavily distorted and may lead to variable ablation. Calculus is preferentially ablated at high fluences (> or =2 J/cm(2)); below this fluence, stalling occurs because of photo-bleaching of the calculus. Healthy dental hard tissue is not removed at fluences < or =3 J/cm(2). Supplying laser light to a tooth using an optical fiber with coaxial water-cooling is determined to be the most appropriate method when selectively removing calculus with a frequency-doubled Ti:sapphire laser. Fluences over 2 J/cm(2) are required to remove calculus efficiently since photo-bleaching stalls calculus removal below that value.

  19. Investigation Into the Optimum Beam Shape and Fluence for Selective Ablation of Dental Calculus at lambda = 400 nm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenly, J.E.; Seka. W.; Rechmann, P.

    A frequency-doubled Ti:sapphire laser is shown to selectively ablate dental calculus. The optimal transverse shape of the laser beam, including its variability under water-cooling, is determined for selective ablation of dental calculus. Intensity profiles under various water-cooling conditions were optically observed. The 400-nm laser was coupled into a multimode optical fiber using an f = 2.5-cm lens and light-shaping diffuser. Water-cooling was supplied coaxially around the fiber. Five human tooth samples (four with calculus and one pristine) were irradiated perpendicular to the tooth surface while the tooth was moved back and forth at 0.3 mm/second, varying between 20 and 180more » iterations. The teeth were imaged before and after irradiation using light microscopy with a flashing blue light-emitting diode (LED). An environmental scanning electron microscope imaged each tooth after irradiation. High-order super-Gaussian intensity profiles are observed at the output of a fiber coiled around a 4-in. diameter drum. Super-Gaussian beams have a morehomogenous fluence distribution than Gaussian beams and have a higher energy efficiency for selective ablation. Coaxial water-cooling does not noticeably distort the intensity distribution within 1 mm from the optical fiber. In contrast, lasers focused to a Gaussian cross section (<=50-mm diameter) without fiber propagation and cooled by a water spray are heavily distorted and may lead to variable ablation. Calculus is preferentially ablated at high fluences (>= 2 J/cm^2); below this fluence, stalling occurs because of photo-bleaching of the calculus. Healthy dental hard tissue is not removed at fluences <=3 J/cm^2. Supplying laser light to a tooth using an optical fiber with coaxial water-cooling is determined to be the most appropriate method when selectively removing calculus with a frequency-doubled Ti:sapphire laser. Fluences over 2 J/cm^2 are required to remove calculus efficiently since photo-bleaching stalls calculus removal below that value.« less

  20. Experimental power spectral density analysis for mid- to high-spatial frequency surface error control.

    PubMed

    Hoyo, Javier Del; Choi, Heejoo; Burge, James H; Kim, Geon-Hee; Kim, Dae Wook

    2017-06-20

    The control of surface errors as a function of spatial frequency is critical during the fabrication of modern optical systems. A large-scale surface figure error is controlled by a guided removal process, such as computer-controlled optical surfacing. Smaller-scale surface errors are controlled by polishing process parameters. Surface errors of only a few millimeters may degrade the performance of an optical system, causing background noise from scattered light and reducing imaging contrast for large optical systems. Conventionally, the microsurface roughness is often given by the root mean square at a high spatial frequency range, with errors within a 0.5×0.5  mm local surface map with 500×500 pixels. This surface specification is not adequate to fully describe the characteristics for advanced optical systems. The process for controlling and minimizing mid- to high-spatial frequency surface errors with periods of up to ∼2-3  mm was investigated for many optical fabrication conditions using the measured surface power spectral density (PSD) of a finished Zerodur optical surface. Then, the surface PSD was systematically related to various fabrication process parameters, such as the grinding methods, polishing interface materials, and polishing compounds. The retraceable experimental polishing conditions and processes used to produce an optimal optical surface PSD are presented.

  1. Improved grid-noise removal in single-frame digital moiré 3D shape measurement

    NASA Astrophysics Data System (ADS)

    Mohammadi, Fatemeh; Kofman, Jonathan

    2016-11-01

    A single-frame grid-noise removal technique was developed for application in single-frame digital-moiré 3D shape measurement. The ability of the stationary wavelet transform (SWT) to prevent oscillation artifacts near discontinuities, and the ability of the Fourier transform (FFT) applied to wavelet coefficients to separate grid-noise from useful image information, were combined in a new technique, SWT-FFT, to remove grid-noise from moiré-pattern images generated by digital moiré. In comparison to previous grid-noise removal techniques in moiré, SWT-FFT avoids the requirement for mechanical translation of optical components and capture of multiple frames, to enable single-frame moiré-based measurement. Experiments using FFT, Discrete Wavelet Transform (DWT), DWT-FFT, and SWT-FFT were performed on moiré-pattern images containing grid noise, generated by digital moiré, for several test objects. SWT-FFT had the best performance in removing high-frequency grid-noise, both straight and curved lines, minimizing artifacts, and preserving the moiré pattern without blurring and degradation. SWT-FFT also had the lowest noise amplitude in the reconstructed height and lowest roughness index for all test objects, indicating best grid-noise removal in comparison to the other techniques.

  2. Surfactants for Bubble Removal against Buoyancy

    PubMed Central

    Raza, Md. Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications. PMID:26743179

  3. Surfactants for Bubble Removal against Buoyancy

    NASA Astrophysics Data System (ADS)

    Raza, Md. Qaisar; Kumar, Nirbhay; Raj, Rishi

    2016-01-01

    The common phenomenon of buoyancy-induced vapor bubble lift-off from a heated surface is of importance to many areas of science and technology. In the absence of buoyancy in zero gravity of space, non-departing bubbles coalesce to form a big dry patch on the heated surface and heat transfer deteriorates despite the high latent heat of vaporization of water. The situation is worse on an inverted heater in earth gravity where both buoyancy and surface tension act upwards to oppose bubble removal. Here we report a robust passive technique which uses surfactants found in common soaps and detergents to avoid coalescence and remove bubbles downwards, away from an inverted heater. A force balance model is developed to demonstrate that the force of repulsion resulting from the interaction of surfactants adsorbed at the neighboring liquid-vapor interfaces of the thin liquid film contained between bubbles is strong enough to overcome buoyancy and surface tension. Bubble removal frequencies in excess of ten Hz resulted in more than twofold enhancement in heat transfer in comparison to pure water. We believe that this novel bubble removal mechanism opens up opportunities for designing boiling-based systems for space applications.

  4. Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting

    PubMed Central

    Yun, S. H.; Tearney, G. J.; de Boer, J. F.; Bouma, B. E.

    2009-01-01

    A novel technique using an acousto-optic frequency shifter in optical frequency domain imaging (OFDI) is presented. The frequency shift eliminates the ambiguity between positive and negative differential delays, effectively doubling the interferometric ranging depth while avoiding image cross-talk. A signal processing algorithm is demonstrated to accommodate nonlinearity in the tuning slope of the wavelength-swept OFDI laser source. PMID:19484034

  5. Automatic Modulation Classification of Common Communication and Pulse Compression Radar Waveforms using Cyclic Features

    DTIC Science & Technology

    2013-03-01

    intermediate frequency LFM linear frequency modulation MAP maximum a posteriori MATLAB® matrix laboratory ML maximun likelihood OFDM orthogonal frequency...spectrum, frequency hopping, and orthogonal frequency division multiplexing ( OFDM ) modulations. Feature analysis would be a good research thrust to...determine feature relevance and decide if removing any features improves performance. Also, extending the system for simulations using a MIMO receiver or

  6. Low and high-frequency TENS in post-episiotomy pain relief: a randomized, double-blind clinical trial.

    PubMed

    Pitangui, Ana C R; Araújo, Rodrigo C; Bezerra, Michelle J S; Ribeiro, Camila O; Nakano, Ana M S

    2014-01-01

    To evaluate the effectiveness of low-frequency TENS (LFT) and high-frequency TENS (HFT) in post-episiotomy pain relief. A randomized, controlled, double-blind clinical trial with placebo composed of 33 puerperae with post-episiotomy pain. TENS was applied for 30 minutes to groups: HFT(100 Hz; 100 µs), LFT (5 Hz; 100 µs), and placebo (PT). Four electrodes were placed in parallel near the episiotomy and four pain evaluations were performed with the numeric rating scale. The first and the second evaluation took place before TENS application and immediately after its removal and were done in the resting position and in the activities of sitting and ambulating. The third and fourth evaluation took place 30 and 60 minutes after TENS removal, only in the resting position. Intragroup differences were verified using the Friedman and Wilcoxon tests, and the intergroup analysis employed the Kruskal-Wallis test. In the intragroup analysis, there was no significant difference in the PT during rest, sitting, and ambulation (P>0.05). In the HFT and LFT, a significant difference was observed in all activities (P<0.001). In the intergroup analysis, there was a significant difference in the resting position in the HFT and LFT (P<0.001). In the sitting activity, a significant difference was verified in the second evaluation in the HFT and LFT (P<0.008). No significant difference was verified among the groups in ambulation (P<0.20). LFT and HFT are an effective resource that may be included in the routine of maternity wards.

  7. Regional Attenuation at PIDC Stations and the Transportability of the S/P Discriminant

    DTIC Science & Technology

    1998-03-31

    amplitude ratios using a variety of frequency bands subject to the constraint that the P-wave frequency is greater than or equal to the 5 - wave frequency... the 5 - wave frequency. First, we discuss our distance and source corrections and show that we were able to remove these dependencies in the data

  8. A straightforward frequency-estimation technique for GPS carrier-phase time transfer.

    PubMed

    Hackman, Christine; Levine, Judah; Parker, Thomas E; Piester, Dirk; Becker, Jürgen

    2006-09-01

    Although Global Positioning System (GPS) carrier-phase time transfer (GPSCPTT) offers frequency stability approaching 10-15 at averaging times of 1 d, a discontinuity occurs in the time-transfer estimates between the end of one processing batch (1-3 d in length) and the beginning of the next. The average frequency over a multiday analysis period often has been computed by first estimating and removing these discontinuities, i.e., through concatenation. We present a new frequency-estimation technique in which frequencies are computed from the individual batches then averaged to obtain the mean frequency for a multiday period. This allows the frequency to be computed without the uncertainty associated with the removal of the discontinuities and requires fewer computational resources. The new technique was tested by comparing the fractional frequency-difference values it yields to those obtained using a GPSCPTT concatenation method and those obtained using two-way satellite time-and-frequency transfer (TWSTFT). The clocks studied were located in Braunschweig, Germany, and in Boulder, CO. The frequencies obtained from the GPSCPTT measurements using either method agreed with those obtained from TWSTFT at several parts in 1016. The frequency values obtained from the GPSCPTT data by use of the new method agreed with those obtained using the concatenation technique at 1-4 x 10(-16).

  9. Learning and robustness to catch-and-release fishing in a shark social network

    PubMed Central

    Brown, Culum; Planes, Serge

    2017-01-01

    Individuals can play different roles in maintaining connectivity and social cohesion in animal populations and thereby influence population robustness to perturbations. We performed a social network analysis in a reef shark population to assess the vulnerability of the global network to node removal under different scenarios. We found that the network was generally robust to the removal of nodes with high centrality. The network appeared also highly robust to experimental fishing. Individual shark catchability decreased as a function of experience, as revealed by comparing capture frequency and site presence. Altogether, these features suggest that individuals learnt to avoid capture, which ultimately increased network robustness to experimental catch-and-release. Our results also suggest that some caution must be taken when using capture–recapture models often used to assess population size as assumptions (such as equal probabilities of capture and recapture) may be violated by individual learning to escape recapture. PMID:28298593

  10. Non local means denoising in photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Siregar, Syahril; Nagaoka, Ryo; Haq, Israr Ul; Saijo, Yoshifumi

    2018-07-01

    Photoacoustic (PA) imaging has the ability to visualize human organs with high spatial resolution and high contrast. Like digital images, PA images are contaminated with random noise due to some parameters. The band-pass filter does not effectively remove the noise because noise is randomly distributed in the bandwidth frequency. We present noise removal method in PA images by using non local means denoising (NLMD) method. The NLMD can be used if there are similarities or redundancies in the image. PA images contain of blood vessel which repeating on the small patch. The method was tested on PA images of carbon nanotubes in micropipe, in vivo mice brain and in vivo mice ear. We estimated the suggested input parameters of NLMD, so it can be automatically applied after scanning the image in PA imaging system. Our results declared that the NLMD enhanced the image quality of PA images.

  11. Inorganic plugs removal using ultrasonic waves

    NASA Astrophysics Data System (ADS)

    Khan, Nasir; Pu, Chunsheng; Xu, Li; Lei, Zhang

    2017-03-01

    It is essential to recover the lost productivity caused by formation damage in the proximity of the wellbore during different well operations. In comparison to conventionally used methods, the efficiency, reliability, environment friendly, and simple and convenient technique of ultrasonic waves make it more attractive in petroleum industries. In current study, ultrasonic waves were applied to mitigate the formation damage caused by deposition of calcium carbonate (CaCO3) nearby well bore. Results showed that 100 minutes exposure time could efficiently recover 38.1% of original productivity but further increase in irradiation time (120mins) would decrease the recovery to 37.1%. This aberration can be attributed to the particle-bridge formation formed by larger particles at later stages and tendency of acoustic wave to push back the fluid flow. Moreover, ultrasonic waves transducer#2 (Frequency 20KHz and Power 1000W) could recovery maximum recovery of 36.3%, however, high frequency transducer was not effective in this recovery. This inorganic removal can be attributed to the cavitation and thermal energy produced through three different ways including cavitation, boundary friction and transformation upon hitting the medium.

  12. Determining the end of a musical turn: Effects of tonal cues.

    PubMed

    Hadley, Lauren V; Sturt, Patrick; Moran, Nikki; Pickering, Martin J

    2018-01-01

    Successful duetting requires that musicians coordinate their performance with their partners. In the case of turn-taking in improvised performance they need to be able to predict their partner's turn-end in order to accurately time their own entries. Here we investigate the cues used for accurate turn-end prediction in musical improvisations, focusing on the role of tonal structure. In a response-time task, participants more accurately determined the endings of (tonal) jazz than (non-tonal) free improvisation turns. Moreover, for the jazz improvisations, removing low frequency information (<2100Hz) - and hence obscuring the pitch relationships conveying tonality - reduced response accuracy, but removing high frequency information (>2100Hz) had no effect. Neither form of filtering affected response accuracy in the free improvisation condition. We therefore argue that tonal cues aided prediction accuracy for the jazz improvisations compared to the free improvisations. We compare our results with those from related speech research (De Ruiter et al., 2006), to draw comparisons between the structural function of tonality and linguistic syntax. Copyright © 2017. Published by Elsevier B.V.

  13. Denitrification in a low-temperature bioreactor system at two different hydraulic residence times: laboratory column studies.

    PubMed

    Nordström, Albin; Herbert, Roger B

    2017-06-01

    Nitrate removal rates in a mixture of pine woodchips and sewage sludge were determined in laboratory column studies at 5°C, 12°C, and 22°C, and at two different hydraulic residence times (HRTs; 58.2-64.0 hours and 18.7-20.6 hours). Baffles installed in the flow path were tested as a measure to reduce preferential flow behavior, and to increase the nitrate removal in the columns. The nitrate removal in the columns was simulated at 5°C and 12°C using a combined Arrhenius-Monod equation controlling the removal rate, and a first-order exchange model for incorporation of stagnant zones. Denitrification in the mixture of pine woodchips and sewage sludge reduced nitrate concentrations of 30 mg N L -1 at 5°C to below detection limits at a HRT of 58.2-64.0 hours. At a HRT of 18.7-20.6 hours, nitrate removal was incomplete. The Arrhenius frequency factor and activation energy retrieved from the low HRT data supported a biochemically controlled reaction rate; the same parameters, however, could not be used to simulate the nitrate removal at high HRT. The results show an inversely proportional relationship between the advection velocity and the nitrate removal rate, suggesting that bioreactor performance could be enhanced by promoting low advection velocities.

  14. Analysis of the Noise in Data from the Mt. Meron Array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chambers, D. H.; Breitfeller, E.

    2010-07-15

    This memo describes an analysis of the noise in data obtained from the Mt. Meron seismic array in northern Israel. The overall objective is to development a method for removing noise from extraneous sources in the environment, increasing the sensitivity to seismic signals from far events. For this initial work, we concentrated on understanding the propagation characteristics of the noise in the frequency band from 0.1 – 8 Hz, and testing a model-based method for removing narrow band (single frequency) noise.

  15. High frequency capacitor-diode voltage multiplier dc-dc converter development

    NASA Technical Reports Server (NTRS)

    Kisch, J. J.; Martinelli, R. M.

    1977-01-01

    A power conditioner was developed which used a capacitor diode voltage multiplier to provide a high voltage without the use of a step-up transformer. The power conditioner delivered 1200 Vdc at 100 watts and was operated from a 120 Vdc line. The efficiency was in excess of 90 percent. The component weight was 197 grams. A modified boost-add circuit was used for the regulation. A short circuit protection circuit was used which turns off the drive circuit upon a fault condition, and recovers within 5 ms after removal of the short. High energy density polysulfone capacitors and high speed diodes were used in the multiplier circuit.

  16. A mean-based filter to remove power line harmonic noise from seismic reflection data

    NASA Astrophysics Data System (ADS)

    Karslı, Hakan; Dondurur, Derman

    2018-06-01

    Power line harmonic noise generated by power lines during the seismic data acquisition in land and marine seismic surveys generally appears as a single frequency with 50/60 Hz (or multiples of these frequencies) and contaminates seismic data leading to complicate the identification of fine details in the data. Commonly applied method during seismic data processing to remove the harmonic noise is classical notch filter (or very narrow band-stop filter), however, it also attenuates all recorded data around the notch frequencies and results in a complete loss of available information which corresponds to fine details in the seismic data. In this study, we introduce an application of the algorithm of iterative trimmed and truncated mean filter method (ITTM) to remove the harmonic noise from seismic data, and here, we name the method as local ITTM (LITTM) since we applied it to the seismic data locally in spectral domain. In this method, an optimal value is iteratively searched depending on a threshold value by trimming and truncating process for the spectral amplitude samples within the specified spectral window. Therefore, the LITTM filter converges to the median, but, there is no need to sort the data as in the case of conventional median filters. On the other hand, the LITTM filtering process doesn't require any reference signal or a precise estimate of the fundamental frequency of the harmonic noise, and only approximate frequency band of the noise within the amplitude spectra is considered. The only required parameter of the method is the width of this frequency band in the spectral domain. The LITTM filter is first applied to synthetic data and then we analyze a real marine dataset to compare the quality of the output after removing the power line noise by classical notch, median and proposed LITTM filters. We observe that the power line harmonic noise is completely filtered out by LITTM filter, and unlike the conventional notch filter, without any damage on the available frequencies around the notch frequency band. It also provides a more balanced amplitude spectrum since it does not produce amplitude notches in the spectrum.

  17. Magnetospheric filter effect for Pc 3 Alfven mode waves

    NASA Technical Reports Server (NTRS)

    Zhang, X.; Comfort, R. H.; Gallagher, D. L.; Green, J. L.; Musielak, Z. E.; Moore, T. E.

    1995-01-01

    We present a ray-tracing study of the propagation of Pc 3 Alfven mode waves originating at the dayside magnetopause. This study reveals interesting features of magnetospheric filter effect for these waves. Pc 3 Alfven mode waves cannot penetrate to low Earth altitudes unless the wave frequency is below approximately 30 mHz. Configurations of the dispersion curves and the refractive index show that the gyroresonance and pseudo-cutoff introduced by the heavy ion O(+) block the waves. When the O(+) concentration is removed from the plasma composition, the barriers caused by the O(+) no longer exist, and waves with much higher frequencies than 30 mHz can penetrate to low altitudes. The result that the 30 mHz or lower frequency Alfven waves can be guided to low altitudes agrees with ground-based power spectrum observation at high altitudes.

  18. Magnetospheric filter effect for Pc 3 Alfven mode waves

    NASA Technical Reports Server (NTRS)

    Zhang, X.; Comfort, R. H.; Gallagher, D. L.; Green, J. L.; Musielak, Z. E.; Moore, T. E.

    1994-01-01

    We present a ray-tracing study of the propagation of Pc 3 Alfven mode waves originating at the dayside magnetopause. This study reveals interesting features of a magnetospheric filter effect for these waves. Pc 3 Alfven mode waves cannot penetrate to low Earth altitudes unless the wave frequency is below approximately 30 mHz. Configurations of the dispersion curves and the refractive index show that the gyroresonance and pseudo-cutoff introduced by the heavy ion O(+) block the waves. When the O(+) concentration is removed from the plasma composition, the barriers caused by the O(+) no longer exist, and waves with much higher frequencies than 30 mHz can penetrate to low altitudes. The result that the 30 mHz or lower frequency Alfven waves can be guided to low altitudes agrees with ground-based power spectrum observations at high latitudes.

  19. Skin effect mitigation in laser processed multi-walled carbon nanotube/copper conductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keramatnejad, K.; Zhou, Y. S.; Gao, Y.

    2015-10-21

    In this study, laser-processed multi-walled carbon nanotube (MWCNT)/Cu conductors are introduced as potential passive components to mitigate the skin effect of Cu at high frequencies (0–10 MHz). Suppressed skin effect is observed in the MWCNT/Cu conductors compared to primitive Cu. At an AC frequency of 10 MHz, a maximum AC resistance reduction of 94% was observed in a MWCNT/Cu conductor after being irradiated at a laser power density of 189 W/cm{sup 2}. The reduced skin effect in the MWCNT/Cu conductors is ascribed to the presence of MWCNT channels which are insensitive to AC frequencies. The laser irradiation process is observed to playmore » a crucial role in reducing contact resistance at the MWCNT-Cu interfaces, removing impurities in MWCNTs, and densifying MWCNT films.« less

  20. Angular analysis of the cyclic impacting oscillations in a robotic grinding process

    NASA Astrophysics Data System (ADS)

    Rafieian, Farzad; Girardin, François; Liu, Zhaoheng; Thomas, Marc; Hazel, Bruce

    2014-02-01

    In a robotic machining process, a light-weight cutter or grinder is usually held by an articulated robot arm. Material removal is achieved by the rotating cutting tool while the robot end effector ensures that the tool follows a programmed trajectory in order to work on complex curved surfaces or to access hard-to-reach areas. One typical application of such process is maintenance and repair work on hydropower equipment. This paper presents an experimental study of the dynamic characteristics of material removal in robotic grinding, which is unlike conventional grinding due to the lower structural stiffness of the tool-holder robot. The objective of the study is to explore the cyclic nature of this mechanical operation to provide the basis for future development of better process control strategies. Grinding tasks that minimize the number of iterations to converge to the target surface can be better planned based on a good understanding and modeling of the cyclic material removal mechanism. A single degree of freedom dynamic analysis of the process suggests that material removal is performed through high-frequency impacts that mainly last for only a small fraction of the grinding disk rotation period. To detect these discrete cutting events in practice, a grinder is equipped with a rotary encoder. The encoder's signal is acquired through the angular sampling technique. A running cyclic synchronous average is applied to the speed signal to remove its non-cyclic events. The measured instantaneous rotational frequency clearly indicates the impacting nature of the process and captures the transient response excited by these cyclic impacts. The technique also locates the angular positions of cutting impacts in revolution cycles. It is thus possible to draw conclusions about the cyclic nature of dynamic changes in impact-cutting behavior when grinding with a flexible robot. The dynamics of the impacting regime and transient responses to impact-cutting excitations captured synchronously using the angular sampling technique provide feedback that can be used to regulate the material removal process. The experimental results also make it possible to correlate the energy required to remove a chip of metal through impacting with the measured drop in angular speed during grinding.

  1. Optimization of removal function in computer controlled optical surfacing

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Guo, Peiji; Ren, Jianfeng

    2010-10-01

    The technical principle of computer controlled optical surfacing (CCOS) and the common method of optimizing removal function that is used in CCOS are introduced in this paper. A new optimizing method time-sharing synthesis of removal function is proposed to solve problems of the removal function being far away from Gaussian type and slow approaching of the removal function error that encountered in the mode of planet motion or translation-rotation. Detailed time-sharing synthesis of using six removal functions is discussed. For a given region on the workpiece, six positions are selected as the centers of the removal function; polishing tool controlled by the executive system of CCOS revolves around each centre to complete a cycle in proper order. The overall removal function obtained by the time-sharing process is the ratio of total material removal in six cycles to time duration of the six cycles, which depends on the arrangement and distribution of the six removal functions. Simulations on the synthesized overall removal functions under two different modes of motion, i.e., planet motion and translation-rotation are performed from which the optimized combination of tool parameters and distribution of time-sharing synthesis removal functions are obtained. The evaluation function when optimizing is determined by an approaching factor which is defined as the ratio of the material removal within the area of half of the polishing tool coverage from the polishing center to the total material removal within the full polishing tool coverage area. After optimization, it is found that the optimized removal function obtained by time-sharing synthesis is closer to the ideal Gaussian type removal function than those by the traditional methods. The time-sharing synthesis method of the removal function provides an efficient way to increase the convergence speed of the surface error in CCOS for the fabrication of aspheric optical surfaces, and to reduce the intermediate- and high-frequency error.

  2. Concepts for a theoretical and experimental study of lifting rotor random loads and vibrations (further experiments with progressing/regressing rotor flapping modes), Phase 7-C

    NASA Technical Reports Server (NTRS)

    Hohenemser, K. H.; Crews, S. T.

    1973-01-01

    The experiments with progressing/regressing forced rotor flapping modes have been extended in several directions and the data processing method has been considerably refined. The 16 inch hingeless 2-bladed rotor model was equipped with a new set of high precision blades which removed previously encountered tracking difficulties at high advance ratio, so that tests up to .8 rotor advance ratio could be conducted. In addition to data with 1.20 blade natural flapping frequency data at 1.10 flapping frequency were obtained. Outside the wind tunnel, tests with a ground plate located at different distances below the rotor were conducted while recording the dynamic downflow at a station .2R below the rotor plane with a hot wire anemometer.

  3. Frequency domain analysis of droplet-based electrostatic transducers

    NASA Astrophysics Data System (ADS)

    Allegretto, Graham; Dobashi, Yuta; Dixon, Katelyn; Wyss, Justin; Yao, Dickson; Madden, John D. W.

    2018-07-01

    Squeezing a water droplet between two electrodes can generate a potential difference by converting some of the mechanical energy in vibrations into electrical energy. By utilizing the high capacitance inherent to electric double layers, and the surface charging at a polymer/water interface, we demonstrate a sensor that generates up to 892 mV peak-to-peak between 1 and 100 Hz, in response to a 250 μm deformation. This frequency response is described and explained using a linearized model in which the interfacial charge acts as the priming voltage, removing the need for external charging normally required in capacitive generators. The model suggests how to design the cell for maximum power output and provides an intuitive understanding of the high pass nature of the sensor. It successfully predicts the point of maximum power transfer.

  4. Electrical heating of soils using high efficiency electrode patterns and power phases

    DOEpatents

    Buettner, Harley M.

    1999-01-01

    Powerline-frequency electrical (joule) heating of soils using a high efficiency electrode configuration and power phase arrangement. The electrode configuration consists of several heating or current injection electrodes around the periphery of a volume of soil to be heated, all electrodes being connected to one phase of a multi-phase or a single-phase power system, and a return or extraction electrode or electrodes located inside the volume to be heated being connected to the remaining phases of the multi-phase power system or to the neutral side of the single-phase power source. This electrode configuration and power phase arrangement can be utilized anywhere where powerline frequency soil heating is applicable and thus has many potential uses including removal of volatile organic compounds such as gasoline and tricholorethylene (TCE) from contaminated areas.

  5. Data needs for tree removal crash modification factors on Arizona state highways.

    DOT National Transportation Integrated Search

    2016-07-01

    The Arizona Department of Transportation (ADOT) Roadway Departure Safety Implementation Plan (RDSIP) has : identified tree removal as a feasible countermeasure to reduce roadway departure crash frequency or severity. : Previous ADOT work has identifi...

  6. Instantaneous and Frequency-Warped Signal Processing Techniques for Auditory Source Separation.

    NASA Astrophysics Data System (ADS)

    Wang, Avery Li-Chun

    This thesis summarizes several contributions to the areas of signal processing and auditory source separation. The philosophy of Frequency-Warped Signal Processing is introduced as a means for separating the AM and FM contributions to the bandwidth of a complex-valued, frequency-varying sinusoid p (n), transforming it into a signal with slowly-varying parameters. This transformation facilitates the removal of p (n) from an additive mixture while minimizing the amount of damage done to other signal components. The average winding rate of a complex-valued phasor is explored as an estimate of the instantaneous frequency. Theorems are provided showing the robustness of this measure. To implement frequency tracking, a Frequency-Locked Loop algorithm is introduced which uses the complex winding error to update its frequency estimate. The input signal is dynamically demodulated and filtered to extract the envelope. This envelope may then be remodulated to reconstruct the target partial, which may be subtracted from the original signal mixture to yield a new, quickly-adapting form of notch filtering. Enhancements to the basic tracker are made which, under certain conditions, attain the Cramer -Rao bound for the instantaneous frequency estimate. To improve tracking, the novel idea of Harmonic -Locked Loop tracking, using N harmonically constrained trackers, is introduced for tracking signals, such as voices and certain musical instruments. The estimated fundamental frequency is computed from a maximum-likelihood weighting of the N tracking estimates, making it highly robust. The result is that harmonic signals, such as voices, can be isolated from complex mixtures in the presence of other spectrally overlapping signals. Additionally, since phase information is preserved, the resynthesized harmonic signals may be removed from the original mixtures with relatively little damage to the residual signal. Finally, a new methodology is given for designing linear-phase FIR filters which require a small fraction of the computational power of conventional FIR implementations. This design strategy is based on truncated and stabilized IIR filters. These signal-processing methods have been applied to the problem of auditory source separation, resulting in voice separation from complex music that is significantly better than previous results at far lower computational cost.

  7. Low frequency radio synthesis imaging of the galactic center region

    NASA Astrophysics Data System (ADS)

    Nord, Michael Evans

    2005-11-01

    The Very Large Array radio interferometer has been equipped with new receivers to allow observations at 330 and 74 MHz, frequencies much lower than were previously possible with this instrument. Though the VLA dishes are not optimal for working at these frequencies, the system is successful and regular observations are now taken at these frequencies. However, new data analysis techniques are required to work at these frequencies. The technique of self- calibration, used to remove small atmospheric effects at higher frequencies, has been adapted to compensate for ionospheric turbulence in much the same way that adaptive optics is used in the optical regime. Faceted imaging techniques are required to compensate for the noncoplanar image distortion that affects the system due to the wide fields of view at these frequencies (~2.3° at 330 MHz and ~11° at 74 MHz). Furthermore, radio frequency interference is a much larger problem at these frequencies than in higher frequencies and novel approaches to its mitigation are required. These new techniques and new system are allowing for imaging of the radio sky at sensitivities and resolutions orders of magnitude higher than were possible with the low frequency systems of decades past. In this work I discuss the advancements in low frequency data techniques required to make high resolution, high sensitivity, large field of view measurements with the new Very Large Array low frequency system and then detail the results of turning this new system and techniques on the center of our Milky Way Galaxy. At 330 MHz I image the Galactic center region with roughly 10 inches resolution and 1.6 mJy beam -1 sensitivity. New Galactic center nonthermal filaments, new pulsar candidates, and the lowest frequency detection to date of the radio source associated with our Galaxy's central massive black hole result. At 74 MHz I image a region of the sky roughly 40° x 6° with, ~10 feet resolution. I use the high opacity of H II regions at 74 MHz to extract three-dimensional data on the distribution of Galactic cosmic ray emissivity, a measurement possible only at low radio frequencies.

  8. High-resolution seismic data regularization and wavefield separation

    NASA Astrophysics Data System (ADS)

    Cao, Aimin; Stump, Brian; DeShon, Heather

    2018-04-01

    We present a new algorithm, non-equispaced fast antileakage Fourier transform (NFALFT), for irregularly sampled seismic data regularization. Synthetic tests from 1-D to 5-D show that the algorithm may efficiently remove leaked energy in the frequency wavenumber domain, and its corresponding regularization process is accurate and fast. Taking advantage of the NFALFT algorithm, we suggest a new method (wavefield separation) for the detection of the Earth's inner core shear wave with irregularly distributed seismic arrays or networks. All interfering seismic phases that propagate along the minor arc are removed from the time window around the PKJKP arrival. The NFALFT algorithm is developed for seismic data, but may also be used for other irregularly sampled temporal or spatial data processing.

  9. Laser ablation of dental calculus at 400 nm using a Ti:sapphire laser

    NASA Astrophysics Data System (ADS)

    Schoenly, Joshua E.; Seka, Wolf; Rechmann, Peter

    2009-02-01

    A Nd:YAG laser-pumped, frequency-doubled Ti:sapphire laser is used for selective ablation of calculus. The laser provides <=25 mJ at 400 nm (60-ns pulse width, 10-Hz repetition rate). The laser is coupled into an optical multimode fiber coiled around a 4-in.-diam drum to generate a top-hat output intensity profile. With coaxial water cooling, this is ideal for efficient, selective calculus removal. This is in stark contrast with tightly focused Gaussian beams that are energetically inefficient and lead to irreproducible results. Calculus is well ablated at high fluences >=2J/cm2 stalling occurs below this fluence because of photobleaching. Healthy hard tissue is not removed at fluences <=3 J/cm2.

  10. Analysis of electrochemical noise (ECN) data in time and frequency domain for comparison corrosion inhibition of some azole compounds on Cu in 1.0 M H2SO4 solution

    NASA Astrophysics Data System (ADS)

    Ramezanzadeh, B.; Arman, S. Y.; Mehdipour, M.; Markhali, B. P.

    2014-01-01

    In this study, the corrosion inhibition properties of two similar heterocyclic compounds namely benzotriazole (BTA) and benzothiazole (BNS) inhibitors on copper in 1.0 M H2SO4 solution were studied by electrochemical techniques as well as surface analysis. The results showed that corrosion inhibition of copper largely depends on the molecular structure and concentration of the inhibitors. The effect of DC trend on the interpretation of electrochemical noise (ECN) results in time domain was evaluated by moving average removal (MAR) method. Accordingly, the impact of square and Hanning window functions as drift removal methods in frequency domain was studied. After DC trend removal, a good trend was observed between electrochemical noise (ECN) data and the results obtained from EIS and potentiodynamic polarization. Furthermore, the shot noise theory in frequency domain was applied to approach the charge of each electrochemical event (q) from the potential and current noise signals.

  11. 47 CFR 78.109 - Major and minor modifications to stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... modulation; (4) Any change in the location of a station transmitter, other than a CARS pickup station... operation of a CARS pickup station; (5) Any change in frequency assignment, including polarization; (6) Any... addition or change in frequency, excluding removing a frequency; (9) Any modification or amendment...

  12. Holographic Optical Elements with Ultra-High Spatial Frequencies.

    DTIC Science & Technology

    1983-01-01

    optical film thickness is equal to one-quarter of the wavelength of the incident radiation and the film’s index of refraction is...Am amount of photoresist material removed by developer N diffractive order number n index of refraction nx index of refraction -- x direction ny index ...since a material with the required index of refraction is usually hard to find4 7 . For example, there is no inorganic material available for

  13. Phase-locking behavior in a high-frequency gymnotiform weakly electric fish, Adontosternarchus.

    PubMed

    Kawasaki, Masashi; Leonard, John

    2017-02-01

    An apteronotid weakly electric fish, Adontosternarchus, emits high-frequency electric organ discharges (700-1500 Hz) which are stable in frequency if no other fish or artificial signals are present. When encountered with an artificial signal of higher frequency than the fish's discharge, the fish raised its discharge frequency and eventually matched its own frequency to that of the artificial signal. At this moment, phase locking was observed, where the timing of the fish's discharge was precisely stabilized at a particular phase of the artificial signal over a long period of time (up to minutes) with microsecond precision. Analyses of the phase-locking behaviors revealed that the phase values of the artificial stimulus at which the fish stabilizes the phase of its own discharge (called lock-in phases) have three populations between -180° and +180°. During the frequency rise and the phase-locking behavior, the electrosensory system is exposed to the mixture of feedback signals from its electric organ discharges and the artificial signal. Since the signal mixture modulates in both amplitude and phase, we explored whether amplitude or phase information participated in driving the phase-locking behavior, using a numerical model. The model which incorporates only amplitude information well predicted the three populations of lock-in phases. When phase information was removed from the electrosensory stimulus, phase-locking behavior was still observed. These results suggest that phase-locking behavior of Adontosternarchus requires amplitude information but not phase information available in the electrosensory stimulus.

  14. Extraction of body waves from seismic ambient noise

    NASA Astrophysics Data System (ADS)

    Kim, Eun Mi; Kang, Tae Seob; Kim, Tae Sung

    2014-05-01

    Ambient noise cross-correlation is used in seismology to obtain the part of the surface waves and applied to the theoretical researches and various experiments. Obtaining the part of body waves from the ambient noise correlation is difficult to recognize because of the feature decreasing body waves along the travel path. However, the travel times of body waves detected from temporal and spacial events occurrence involve uncertainty of the epicenter and accompany temporal-spacial restriction. On the other hand, ambient noise is always occurred and is obtained at the all stations. So it can be applied to research of the internal earth when the case of extracting the body waves using the cross-correlation is possible. This study shows that body waves can be observed by analyzing the ambient noise recorded seismic data in South Korea. Using 42 broad-band three components stations located on the South Korea. The data removed the mean and trend are filtered high-frequency band(0.5-2Hz). The noise correlations were calculated for all combinations of radial, transverse and veltical components, which required rotation of the horizontal components for each station pair according to the azimuth at each station of the great-circle between the two stations. Removing the part of broad-band signals effected by occurring event, the part of standard deviations more than three times are removed. And it applied spectral whitening to reduce effects of the surface waves. After data processing, all ambient noise signals are cross-correlated and temporal stacked. We found the signals propagating from one station to another station, this signals can be interpreted as the body waves distinguished surface travel-time in high-frequency band.From this analysis, we can extract the body waves using ambient noise cross correlation of continuous data at the stations.

  15. Acoustic bubble removal method

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Elleman, D. D.; Wang, T. G. (Inventor)

    1983-01-01

    A method is described for removing bubbles from a liquid bath such as a bath of molten glass to be used for optical elements. Larger bubbles are first removed by applying acoustic energy resonant to a bath dimension to drive the larger bubbles toward a pressure well where the bubbles can coalesce and then be more easily removed. Thereafter, submillimeter bubbles are removed by applying acoustic energy of frequencies resonant to the small bubbles to oscillate them and thereby stir liquid immediately about the bubbles to facilitate their breakup and absorption into the liquid.

  16. Characteristics and processing of seismic data collected on thick, floating ice: Results from the Ross Ice Shelf, Antarctica

    USGS Publications Warehouse

    Beaudoin, Bruce C.; ten Brink, Uri S.; Stern, Tim A.

    1992-01-01

    Coincident reflection and refraction data, collected in the austral summer of 1988/89 by Stanford University and the Geophysical Division of the Department of Scientific and Industrial Research, New Zealand, imaged the crust beneath the Ross Ice Shelf, Antarctica. The Ross Ice Shelf is a unique acquisition environment for seismic reflection profiling because of its thick, floating ice cover. The ice shelf velocity structure is multilayered with a high velocity‐gradient firn layer constituting the upper 50 to 100 m. This near surface firn layer influences the data character by amplifying and frequency modulating the incoming wavefield. In addition, the ice‐water column introduces pervasive, high energy seafloor, intra‐ice, and intra‐water multiples that have moveout velocities similar to the expected subseafloor primary velocities. Successful removal of these high energy multiples relies on predictive deconvolution, inverse velocity stack filtering, and frequency filtering. Removal of the multiples reveals a faulted, sedimentary wedge which is truncated at or near the seafloor. Beneath this wedge the reflection character is diffractive to a two‐way traveltime of ∼7.2 s. At this time, a prominent reflection is evident on the southeast end of the reflection profile. This reflection is interpreted as Moho indicating that the crust is ∼21-km thick beneath the profile. These results provide seismic evidence that the extensional features observed in the Ross Sea region of the Ross Embayment extend beneath the Ross Ice Shelf.

  17. Effective resolution concepts for lidar observations

    NASA Astrophysics Data System (ADS)

    Iarlori, M.; Madonna, F.; Rizi, V.; Trickl, T.; Amodeo, A.

    2015-12-01

    Since its establishment in 2000, EARLINET (European Aerosol Research Lidar NETwork) has provided, through its database, quantitative aerosol properties, such as aerosol backscatter and aerosol extinction coefficients, the latter only for stations able to retrieve it independently (from Raman or high-spectral-resolution lidars). These coefficients are stored in terms of vertical profiles, and the EARLINET database also includes the details of the range resolution of the vertical profiles. In fact, the algorithms used in the lidar data analysis often alter the spectral content of the data, mainly acting as low-pass filters to reduce the high-frequency noise. Data filtering is described by the digital signal processing (DSP) theory as a convolution sum: each filtered signal output at a given range is the result of a linear combination of several signal input data samples (relative to different ranges from the lidar receiver), and this could be seen as a loss of range resolution of the output signal. Low-pass filtering always introduces distortions in the lidar profile shape. Thus, both the removal of high frequency, i.e., the removal of details up to a certain spatial extension, and the spatial distortion produce a reduction of the range resolution. This paper discusses the determination of the effective resolution (ERes) of the vertical profiles of aerosol properties retrieved from lidar data. Large attention has been dedicated to providing an assessment of the impact of low-pass filtering on the effective range resolution in the retrieval procedure.

  18. Suppressing multiples using an adaptive multichannel filter based on L1-norm

    NASA Astrophysics Data System (ADS)

    Shi, Ying; Jing, Hongliang; Zhang, Wenwu; Ning, Dezhi

    2017-08-01

    Adaptive subtraction is an important link for removing surface-related multiples in the wave equation-based method. In this paper, we propose an adaptive multichannel subtraction method based on the L1-norm. We achieve enhanced compensation for the mismatch between the input seismogram and the predicted multiples in terms of the amplitude, phase, frequency band, and travel time. Unlike the conventional L2-norm, the proposed method does not rely on the assumption that the primary and the multiples are orthogonal, and also takes advantage of the fact that the L1-norm is more robust when dealing with outliers. In addition, we propose a frequency band extension via modulation to reconstruct the high frequencies to compensate for the frequency misalignment. We present a parallel computing scheme to accelerate the subtraction algorithm on graphic processing units (GPUs), which significantly reduces the computational cost. The synthetic and field seismic data tests show that the proposed method effectively suppresses the multiples.

  19. Ultrasound breast imaging using frequency domain reverse time migration

    NASA Astrophysics Data System (ADS)

    Roy, O.; Zuberi, M. A. H.; Pratt, R. G.; Duric, N.

    2016-04-01

    Conventional ultrasonography reconstruction techniques, such as B-mode, are based on a simple wave propagation model derived from a high frequency approximation. Therefore, to minimize model mismatch, the central frequency of the input pulse is typically chosen between 3 and 15 megahertz. Despite the increase in theoretical resolution, operating at higher frequencies comes at the cost of lower signal-to-noise ratio. This ultimately degrades the image contrast and overall quality at higher imaging depths. To address this issue, we investigate a reflection imaging technique, known as reverse time migration, which uses a more accurate propagation model for reconstruction. We present preliminary simulation results as well as physical phantom image reconstructions obtained using data acquired with a breast imaging ultrasound tomography prototype. The original reconstructions are filtered to remove low-wavenumber artifacts that arise due to the inclusion of the direct arrivals. We demonstrate the advantage of using an accurate sound speed model in the reverse time migration process. We also explain how the increase in computational complexity can be mitigated using a frequency domain approach and a parallel computing platform.

  20. Using high-resolution variant frequencies to empower clinical genome interpretation.

    PubMed

    Whiffin, Nicola; Minikel, Eric; Walsh, Roddy; O'Donnell-Luria, Anne H; Karczewski, Konrad; Ing, Alexander Y; Barton, Paul J R; Funke, Birgit; Cook, Stuart A; MacArthur, Daniel; Ware, James S

    2017-10-01

    PurposeWhole-exome and whole-genome sequencing have transformed the discovery of genetic variants that cause human Mendelian disease, but discriminating pathogenic from benign variants remains a daunting challenge. Rarity is recognized as a necessary, although not sufficient, criterion for pathogenicity, but frequency cutoffs used in Mendelian analysis are often arbitrary and overly lenient. Recent very large reference datasets, such as the Exome Aggregation Consortium (ExAC), provide an unprecedented opportunity to obtain robust frequency estimates even for very rare variants.MethodsWe present a statistical framework for the frequency-based filtering of candidate disease-causing variants, accounting for disease prevalence, genetic and allelic heterogeneity, inheritance mode, penetrance, and sampling variance in reference datasets.ResultsUsing the example of cardiomyopathy, we show that our approach reduces by two-thirds the number of candidate variants under consideration in the average exome, without removing true pathogenic variants (false-positive rate<0.001).ConclusionWe outline a statistically robust framework for assessing whether a variant is "too common" to be causative for a Mendelian disorder of interest. We present precomputed allele frequency cutoffs for all variants in the ExAC dataset.

  1. Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis

    PubMed Central

    Weyer, Sören; Pauly, Karolin; Napp, Andreas; Dreher, Michael; Leonhardt, Steffen; Marx, Nikolaus; Schauerte, Patrick; Mischke, Karl

    2015-01-01

    Background. Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. Methods. 45 participants (21 with pleural effusion and 24 healthy subjects) were included. Bioelectrical impedance was analyzed for “Transthoracic,” “Foot to Foot,” “Foot to Hand,” and “Hand to Hand” vectors in low and high frequency domain before and after thoracentesis. Healthy subjects were measured at a single time point. Results. The mean volume of removed pleural effusion was 1169 ± 513 mL. The “Foot to Foot,” “Hand to Hand,” and “Foot to Hand” vector indicated a trend for increased bioelectrical impedance after thoracentesis. Values for the low frequency domain in the “Transthoracic” vector increased significantly (P < 0.001). A moderate correlation was observed between the amount of removed fluid and impedance change in the low frequency domain using the “Foot to Hand” vector (r = −0.7). Conclusion. Bioelectrical impedance changes in correlation with the thoracic fluid level. It was feasible to monitor significant fluid shifts and loss after thoracentesis in the “Transthoracic” vector by means of bioelectrical impedance spectroscopy. The trial is registered with Registration Numbers IRB EK206/11 and NCT01778270. PMID:25861647

  2. The importance of hyaluronic acid in vocal fold biomechanics.

    PubMed

    Chan, R W; Gray, S D; Titze, I R

    2001-06-01

    This study examined the influence of hyaluronic acid (HA) on the biomechanical properties of the human vocal fold cover (the superficial layer of the lamina propria). Vocal fold tissues were freshly excised from 5 adult male cadavers and were treated with bovine testicular hyaluronidase to selectively remove HA from the lamina propria extracellular matrix (ECM). Linear viscoelastic shear properties (elastic shear modulus and dynamic viscosity) of the tissue samples before and after enzymatic treatment were quantified as a function of frequency (0.01 to 15 Hz) by a parallel-plate rotational rheometer at 37 degrees C. On removing HA from the vocal fold ECM, the elastic shear modulus (G' ) or stiffness of the vocal fold cover decreased by an average of around 35%, while the dynamic viscosity (eta') increased by 70% at higher frequencies (>1 Hz). The results suggested that HA plays an important role in determining the biomechanical properties of the vocal fold cover. As a highly hydrated glycosaminoglycan in the vocal fold ECM, it likely contributes to the maintenance of an optimal tissue viscosity that may facilitate phonation, and an optimal tissue stiffness that may be important for vocal fundamental frequency control. HA has been proposed as a potential bioimplant for the surgical repair of vocal fold ECM defects (eg, vocal fold scarring and sulcus vocalis). Our results suggested that such clinical use may be potentially optimal for voice production from a biomechanical perspective.

  3. Calcium-dependent control of temporal processing in an auditory interneuron: a computational analysis

    PubMed Central

    Ponnath, Abhilash

    2010-01-01

    Sensitivity to acoustic amplitude modulation in crickets differs between species and depends on carrier frequency (e.g., calling song vs. bat-ultrasound bands). Using computational tools, we explore how Ca2+-dependent mechanisms underlying selective attention can contribute to such differences in amplitude modulation sensitivity. For omega neuron 1 (ON1), selective attention is mediated by Ca2+-dependent feedback: [Ca2+]internal increases with excitation, activating a Ca2+-dependent after-hyperpolarizing current. We propose that Ca2+ removal rate and the size of the after-hyperpolarizing current can determine ON1’s temporal modulation transfer function (TMTF). This is tested using a conductance-based simulation calibrated to responses in vivo. The model shows that parameter values that simulate responses to single pulses are sufficient in simulating responses to modulated stimuli: no special modulation-sensitive mechanisms are necessary, as high and low-pass portions of the TMTF are due to Ca2+-dependent spike frequency adaptation and post-synaptic potential depression, respectively. Furthermore, variance in the two biophysical parameters is sufficient to produce TMTFs of varying bandwidth, shifting amplitude modulation sensitivity like that in different species and in response to different carrier frequencies. Thus, the hypothesis that the size of after-hyperpolarizing current and the rate of Ca2+ removal can affect amplitude modulation sensitivity is computationally validated. PMID:20559640

  4. Use of Standalone GPS for Approach with Vertical Guidance.

    DOT National Transportation Integrated Search

    2001-01-22

    The accuracy of GPS has improved dramatically over the past year with the removal of Selective Availability. The largest error source now is the ionosphere which can be removed in the future when the additional civil frequencies become available. Pre...

  5. Decomposition of mixed malodorants in a wire-plate pulse corona reactor.

    PubMed

    Shi, Y; Ruan, J; Wang, X; Li, W; Tan, T

    2005-09-01

    Decomposition characteristics of two groups of representative mixed malodorants (1, ethanethiol + hydrogen sulfide; 2, ethanethiol + ammonia) in air were investigated employing a wire-plate pulse corona reactor. A new type of high-voltage pulse generator with a thyratron switch and a Blumlein pulse-forming network (BPFN) was used in our experiments. The experiments were conducted at a gas-flow rate of 13 m3/h. Important parameters, including peak voltage, chemical structures of malodorants, pulse frequency, and initial concentration, which influenced the removal efficiency, were investigated. The results showed that the mixed malodorants could be treated effectively by pulse corona. The removal efficiencies of 200 mg/m3 C2H5SH and 200 mg/m3 H2S for group 1 were 95.6% and 100%, respectively, which were almost equal to those of the two pollutants separately. The energy cost was about 65.1-81.4 J/L, which was 31.5-45.2% lower than for treating pollutants alone. The removal efficiencies of 105 mg/m3 C2HsSH and 40 mg/m3 NH3 for group 2 were 93.1% and almost 100%, and the energy cost was 65.1 J/L, 55.6% lower than that which was treated separately. In the case of two groups of mixed malodorants removal, NOx, 03, SO2, CO2, and CO were all observed. Moreover, some sulfur and white crystal ammonium nitrates were discovered adhering to the corona wires in the removal of groups 1 and 2, respectively. A dynamics model was developed to describe the relation of the removal efficiency with specific energy density and initial concentration. In the case of group 1 removal,the decomposition rate constants decreased as compared to the single treating. As for group 2 removal, the decomposition rate constants increased, especially for NH3. According to the results, the optimization design for the reactor and the matching of high pulse voltage source can be reckoned.

  6. Surface Currents and Winds at the Delaware Bay Mouth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muscarella, P A; Barton, N P; Lipphardt, B L

    2011-04-06

    Knowledge of the circulation of estuaries and adjacent shelf waters has relied on hydrographic measurements, moorings, and local wind observations usually removed from the region of interest. Although these observations are certainly sufficient to identify major characteristics, they lack both spatial resolution and temporal coverage. High resolution synoptic observations are required to identify important coastal processes at smaller scales. Long observation periods are needed to properly sample low-frequency processes that may also be important. The introduction of high-frequency (HF) radar measurements and regional wind models for coastal studies is changing this situation. Here we analyze synoptic, high-resolution surface winds andmore » currents in the Delaware Bay mouth over an eight-month period (October 2007 through May 2008). The surface currents were measured by two high-frequency radars while the surface winds were extracted from a data-assimilating regional wind model. To illustrate the utility of these monitoring tools we focus on two 45-day periods which previously were shown to present contrasting pictures of the circulation. One, the low-outflow period is from 1 October through 14 November 2007; the other is the high-outflow period from 3 March through 16 April 2008. The large-scale characteristics noted by previous workers are clearly corroborated. Specifically the M2 tide dominates the surface currents, and the Delaware Bay outflow plume is clearly evident in the low frequency currents. Several new aspects of the surface circulation were also identified. These include a map of the spatial variability of the M2 tide (validating an earlier model study), persistent low-frequency cross-mouth flow, and a rapid response of the surface currents to a changing wind field. However, strong wind episodes did not persist long enough to set up a sustained Ekman response.« less

  7. RF plasma cleaning of silicon substrates with high-density polyethylene contamination

    NASA Astrophysics Data System (ADS)

    Cagomoc, Charisse Marie D.; De Leon, Mark Jeffry D.; Ebuen, Anna Sophia M.; Gilos, Marlo Nicole R.; Vasquez, Magdaleno R., Jr.

    2018-01-01

    Upon contact with a polymeric material, microparticles from the polymer may adhere to a silicon (Si) substrate during device processing. The adhesion contaminates the surface and, in turn, leads to defects in the fabricated Si-based microelectronic devices. In this study, Si substrates with artificially induced high-density polyethylene (HDPE) contamination was exposed to 13.56 MHz radio frequency (RF) plasma utilizing argon and oxygen gas admixtures at a power density of 5.6 W/cm2 and a working pressure of 110 Pa for up to 6 min of treatment. Optical microscopy studies revealed the removal of up to 74% of the polymer contamination upon plasma exposure. Surface free energy (SFE) increased owing to the removal of contaminants as well as the formation of polar groups on the Si surface after plasma treatment. Atomic force microscopy scans showed a decrease in surface roughness from 12.25 nm for contaminated samples to 0.77 nm after plasma cleaning. The smoothening effect can be attributed to the removal of HDPE particles from the surface. In addition, scanning electron microscope images showed that there was a decrease in the amount of HDPE contaminants adhering onto the surface after plasma exposure.

  8. NO Removal with Repetitive Discharges Caused by Reciprocal Traveling Wave Voltage Pulse in a Coaxial Cable

    NASA Astrophysics Data System (ADS)

    Yamaga, Keisuke; Kadowaki, Kazunori; Nishimoto, Sakae; Kitani, Isamu

    This paper describes experimental results of NO removal using barrier discharges produced by a reciprocal pulse generator. When a coaxial cable is charged and then grounded at one end of the cable without any resistance, a reciprocal traveling voltage pulse is repeatedly applied to a barrier-type reactor at the opposite end with a change in its polarity. 50% streamer initiation voltage for the reciprocal pulse generator was much smaller than that with the self-matched pulse generator having a matching resistance. The reason for the low initiation voltage in the reciprocal pulse was that space charges which accumulated on the barrier surface during cable charging had an effect on field enhancement in the reactor after the first polarity reversal. High speed photographs of discharge light produced by the reciprocal pulse showed that the voltage oscillation caused by one switching induced alternate propagation of positive and negative streamers with a very high frequency. In measurements of NO concentration, the reciprocal pulse generator gave a better performance for NO removal ratio than the self-matched pulse generator even though the stored energy in the recipocal pulse generator was very low.

  9. Liposuction for removal of lipomas in 20 dogs.

    PubMed

    Hunt, G B; Wong, J; Kuan, S

    2011-08-01

    To review the success rates for liposuction of lipomas in dogs, report early complications and medium-term outcomes and formulate recommendations on the most appropriate candidates for liposuction. Retrospective study of 20 dogs with 76 lipomas diagnosed by cytology, in which dry liposuction was attempted. Case records were reviewed for number and size of the lipomas, efficacy of liposuction, frequency and types of complication and likelihood of recurrence. Liposuction was successful in removing 73 of 76 lipomas (96%). Simple, encapsulated lipomas less than 15 cm in diameter were most easily removed, with minimal risk of complication. Giant lipomas contained fibrous trabeculae that hindered liposuction and resulted in poor fat retrieval. Giant lipomas were also associated with a high risk of bruising, haematoma and seroma, especially when inguinal in location. Regrowth was noted at follow-up between 9 and 36 months in 28% of lipomas. Liposuction may be less invasive and more attractive to owners than conventional surgery for lipomas up to 15 cm in diameter. Liposuction is not recommended for infiltrative or giant inguinal lipomas. Regrowth can be expected in a high proportion of lipomas, which should be considered when choosing liposuction over conventional excision. © 2011 British Small Animal Veterinary Association.

  10. Noise Reduction of Ocean-Bottom Pressure Data Toward Real-Time Tsunami Forecasting

    NASA Astrophysics Data System (ADS)

    Tsushima, H.; Hino, R.

    2008-12-01

    We discuss a method of noise reduction of ocean-bottom pressure data to be fed into the near-field tsunami forecasting scheme proposed by Tsushima et al. [2008a]. In their scheme, the pressure data is processed in real time as follows: (1) removing ocean tide components by subtracting the sea-level variation computed from a theoretical tide model, (2) applying low-pass digital filter to remove high-frequency fluctuation due to seismic waves, and (3) removing DC-offset and linear-trend component to determine a baseline of relative sea level. However, it turns out this simple method is not always successful in extracting tsunami waveforms from the data, when the observed amplitude is ~1cm. For disaster mitigation, accurate forecasting of small tsunamis is important as well as large tsunamis. Since small tsunami events occur frequently, successful tsunami forecasting of those events are critical to obtain public reliance upon tsunami warnings. As a test case, we applied the data-processing described above to the bottom pressure records containing tsunami with amplitude less than 1 cm which was generated by the 2003 Off-Fukushima earthquake occurring in the Japan Trench subduction zone. The observed pressure variation due to the ocean tide is well explained by the calculated tide signals from NAO99Jb model [Matsumoto et al., 2000]. However, the tide components estimated by BAYTAP-G [Tamura et al., 1991] from the pressure data is more appropriate for predicting and removing the ocean tide signals. In the pressure data after removing the tide variations, there remain pressure fluctuations with frequencies ranging from about 0.1 to 1 mHz and with amplitudes around ~10 cm. These fluctuations distort the estimation of zero-level and linear trend to define relative sea-level variation, which is treated as tsunami waveform in the subsequent analysis. Since the linear trend is estimated from the data prior to the origin time of the earthquake, an artificial linear trend is produced in the processed waveform. This artificial linear trend degrades the accuracy of the tsunami forecasting, although the forecasting result is expected to be robust against the existence of short-period noise [Tsushima et al., 2008a]. Since the bottom pressure show gradual increase (or decrease) in the tsunami source region [Tsushima et al., 2008b], it is important to remove the linear trend not related to the tsunami generation from the data before fed into the analysis. Therefore, the reduction of the noise in sub-mHz band is critical for the forecasting small tsunamis. Applying a kind of frequency filters to eliminate this noise cannot be a solution for this problem because actual tsunami signals may also contain components of this frequency band. We investigate whether any statistical modelings of the noise are effective for reducing the sub-mHz noise.

  11. Description of a 2.3 kW power transformer for space applications

    NASA Technical Reports Server (NTRS)

    Hansen, I.

    1979-01-01

    The principle features and special testing of a high voltage high power transformer designed and developed for space application are described. The transformer is operated in a series resonant inverter supplying beam power to a 30 cm mercury ion thruster. Electrical requirements include operation of 2.3 kW continuous power output, primary currents to 35 amps rms, and frequencies up to 20 kHz. High efficiency was obtained through detailed considerations of the tradeoffs available in core materials, wire selection, coil configurations and thermal control. A number of novel heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

  12. Thermal analysis and optimization of the EAST ICRH antenna

    NASA Astrophysics Data System (ADS)

    Qingxi, YANG; Wei, SONG; Qunshan, DU; Yuntao, SONG; Chengming, QIN; Xinjun, ZHANG; Yanping, ZHAO

    2018-02-01

    The ion cyclotron resonance of frequency heating (ICRH) plays an important role in plasma heating. Two ICRH antennas were designed and applied on the EAST tokamak. In order to meet the requirement imposed by high-power and long-pulse operation of EAST in the future, an active cooling system is mandatory to be designed to remove the heat load deposited on the components. Thermal analyses for high heat-load components have been carried out, which presented clear temperature distribution on each component and provided the reference data to do the optimization. Meanwhile, heat pipes were designed to satisfy the high requirement imposed by a Faraday shield and lateral limiter.

  13. Is Dam Removal a Benefit for Environment? Input of Sedimentary Archives

    NASA Astrophysics Data System (ADS)

    Debret, M.; Laberdesque, Y.; Patault, E.; Copard, Y.; Koltalo, F.; Marcotte, S.; Sabatier, P.; Develle, A. L.; Chaumillon, E.; Coulombier, T.; Deloffre, J.; Fournier, M.; Landemaine, V.; Laignel, B.; Desmet, M.

    2016-12-01

    In October 2015, the scientific news EOS entitled: « Contaminated sediment and dam removal: problem or opportunity? ». This title clearly highlights the problems that societies of every country are facing: many dam are about to exceed their engineered life expectancies and large quantities of contaminated sediments are stored by theses structures. Moreover in Europe, since the 2000s, the European legislative and regulatory framework highlights the consideration of the morphological operation for hydro-systems. The objective of achieving good ecological status of waters by 2015 brings watershed management authorities to consider the removal of dams to restore the free movement of sediment. But until now, the impacts associated with the removal of structures are poorly studied. The Martot dam, chosen in this study is located on the Eure River (Seine river tributary, north of France). It is an ideal case study, because its coming destruction, for ecological continuity restoration, is a "priority" and a large quantity of contaminated sediments is supposed to be stored upstream, related to high industrial concentration since decades. We investigated the evolution of the hydro-sedimentary transfers on the watershed of the Eure River and determined the nature of the contaminants stored in the sediments that are subject to be remobilized after the dam removal. To achieve these goals, we reconstructed the Eure catchment area history by studying seismic profiles, in-situt high frequency monitoring (since 2 years: flow, electrical conductivity, temperrature, turbidity, suspended particulate matter concentration) and sedimentary cores. Then, the nature, origin and timing of pollutants stored in the Eure sediments were determined. The next step will be to evaluate their bio-accessibility and the danger for trophic chain and evaluate if the removal was a benefit or problem for environment.

  14. [The extraction and analysis of a- and b- wave from electroretinogram in human].

    PubMed

    Chen, Zi-he; Zheng, Chang-wei; Lei, Bo

    2013-12-01

    To determine the frequency range of a-b wave complex in the dark- and light-adapted electroretinogram (ERG) and to isolate the pure a- and b- waves. Case series study. Full-field ERGs were recorded in 16 eyes of 8 normal volunteers from October to November 2011. Digital filtering technique was used to extract the a- and b-waves from dark- and light-adapted ERG responses. The timings of a- and b-wave were measured to determine the frequency range of a-b wave complex. Major frequency components were determined from power spectra using fast Fourier transform (FFT). The effect of different order settings in the digital filter were compared to investigate the optimum condition, where the oscillatory potential (OP) was completely removed while the amplitudes and phases of the a- and b- waves were less affected. The Student-t test was used to compare the frequency range of a-b wave complex in dark- and light-adapted ERG. The averaged frequency range of the dark-adapted a-b wave complex was from (14.99 ± 2.39) to (25.35 ± 3.77) Hz, compared with (25.22 ± 6.56) to (32.47 ± 3.68) Hz for the light-adapted a-b wave complex, respectively, indicating the frequency range of the dark-adapted a-b wave complex was significantly less than the light-adapted a-b wave complex (t = 7.910, 7.693; both P < 0.01). The third order of the digital filter and a passband of 1 to 45 Hz was the best choice in term of removing the high frequency OP from the waveform of ERG and keeping the amplitude and phase of the a- and b- waves. The frequency of a-b wave complex is lower than that of OP. Therefore the a- and b- waves can be isolated from OP using different digital filter settings in human ERG. A third order and a passband of 1 to 45 Hz is the best choice to extract pure a- and b- waves from the original ERG.

  15. Low-cost, high-fidelity, adaptive cancellation of periodic 60 Hz noise.

    PubMed

    Wesson, Kyle D; Ochshorn, Robert M; Land, Bruce R

    2009-12-15

    A common method to eliminate unwanted power line interference in neurobiology laboratories where sensitive electronic signals are measured is with a notch filter. However a fixed-frequency notch filter cannot remove all power line noise contamination since inherent frequency and phase variations exist in the contaminating signal. One way to overcome the limitations of a fixed-frequency notch filter is with adaptive noise cancellation. Adaptive noise cancellation is an active approach that uses feedback to create a signal that when summed with the contaminated signal destructively interferes with the noise component leaving only the desired signal. We have implemented an optimized least mean square adaptive noise cancellation algorithm on a low-cost 16 MHz, 8-bit microcontroller to adaptively cancel periodic 60 Hz noise. In our implementation, we achieve between 20 and 25 dB of cancellation of the fundamental 60 Hz noise component.

  16. Antibiotic failure mediated by a resistant subpopulation in Enterobacter cloacae

    PubMed Central

    Band, Victor I.; Crispell, Emily K.; Napier, Brooke A.; Herrera, Carmen M.; Tharp, Greg K.; Vavikolanu, Kranthi; Pohl, Jan; Read, Timothy D.; Bosinger, Steven E.; Trent, M. Stephen; Burd, Eileen M.; Weiss, David S.

    2016-01-01

    Antibiotic resistance is a major public health threat, further complicated by unexplained treatment failures caused by bacteria that appear antibiotic susceptible. We describe an Enterobacter cloacae isolate harbouring a minor subpopulation that is highly resistant to the last-line antibiotic colistin. This subpopulation was distinct from persisters, became predominant in colistin, returned to baseline after colistin removal and was dependent on the histidine kinase PhoQ. During murine infection, but in the absence of colistin, innate immune defences led to an increased frequency of the resistant subpopulation, leading to inefficacy of subsequent colistin therapy. An isolate with a lower-frequency colistin-resistant subpopulation similarly caused treatment failure but was misclassified as susceptible by current diagnostics once cultured outside the host. These data demonstrate the ability of low-frequency bacterial subpopulations to contribute to clinically relevant antibiotic resistance, elucidating an enigmatic cause of antibiotic treatment failure and highlighting the critical need for more sensitive diagnostics. PMID:27572838

  17. Validating simple dynamical simulations of the unitary Fermi gas

    NASA Astrophysics Data System (ADS)

    Forbes, Michael McNeil; Sharma, Rishi

    2014-10-01

    We present a comparison between simulated dynamics of the unitary fermion gas using the superfluid local density approximation (SLDA) and a simplified bosonic model, the extended Thomas-Fermi (ETF) with a unitary equation of state. Small-amplitude fluctuations have similar dynamics in both theories for frequencies far below the pair-breaking threshold and wave vectors much smaller than the Fermi momentum. The low-frequency linear responses in both match well for surprisingly large wave vectors, even up to the Fermi momentum. For nonlinear dynamics such as vortex generation, the ETF provides a semiquantitative description of SLDA dynamics as long as the fluctuations do not have significant power near the pair-breaking threshold; otherwise the dynamics of the ETF cannot be trusted. Nonlinearities in the ETF tend to generate high-frequency fluctuations, and with no normal component to remove this energy from the superfluid, features such as vortex lattices cannot relax and crystallize as they do in the SLDA.

  18. Planck and the reionization of the universe

    NASA Astrophysics Data System (ADS)

    Crill, Brendan

    2016-03-01

    Planck is the third-generation satellite aimed at measuring the cosmic microwave background, a relic of the hot big bang. Planck's temperature and polarization maps of the millimeter-wave sky have constrained parameters of the standard lambda-CDM model of cosmology to incredible precision, and have provided constraints on inflation in the very early universe. Planck's all-sky survey of polarization in seven frequency bands can remove contamination from nearby Galactic emission and constrain the optical depth of the reionized Universe, giving insight into the properties of the earliest star formation. The final 2016 data release from Planck will include a refined optical depth measurement using the full sensitivity of both the High Frequency and Low Frequency instruments. I present the status of the reionization measurement and discuss future prospects for further measurements of the early Universe with the CMB from Planck and future space and suborbital platforms.

  19. Water-cooled, high-intensity ultrasound surgical applicators with frequency tracking.

    PubMed

    Martin, Roy W; Vaezy, Shahram; Proctor, Andrew; Myntti, Terrence; Lee, Janelle B J; Crum, Lawrence A

    2003-10-01

    High-intensity, focused ultrasound (HIFU) applicators have been developed for arresting bleeding with the ultimate intent of use in surgery. The design uses a tapered titanium component for transmission coupling of the ultrasound energy from a spherically curved transducer to biological tissues. The nominal operating frequency is 5.5 MHz, in a highly resonant mode (quality factor of 327 with water load). Liquid cooling is used to remove energy loss important at net applied power greater than 18 W/cm2 at the surface of the piezoelectric element. A downward resonance frequency shift (>20 kHz) occurs, even with cooling, as the applicator warms with normal operation. A feedback technique is used for maintaining the excitation near optimum resonance. Standing wave ratios of the applied power of 1.6 or less are thus sustained. The system and applicators have been found to be highly robust, effective in achieving hemostasis in the hemorrhaging liver, spleen, lung, or blood vessels in rabbit and pig experiments. One unit has been operated for over 1.7 hours in treating organ hemorrhage in blunt trauma experiments with nine swine with electrical net power of up to 158 W (31 W/cm2 across the transducer) and intensity of 2560 W/cm2 at focus.

  20. Real-Time Point Positioning Performance Evaluation of Single-Frequency Receivers Using NASA's Global Differential GPS System

    NASA Technical Reports Server (NTRS)

    Muellerschoen, Ronald J.; Iijima, Byron; Meyer, Robert; Bar-Sever, Yoaz; Accad, Elie

    2004-01-01

    This paper evaluates the performance of a single-frequency receiver using the 1-Hz differential corrections as provided by NASA's global differential GPS system. While the dual-frequency user has the ability to eliminate the ionosphere error by taking a linear combination of observables, the single-frequency user must remove or calibrate this error by other means. To remove the ionosphere error we take advantage of the fact that the magnitude of the group delay in range observable and the carrier phase advance have the same magnitude but are opposite in sign. A way to calibrate this error is to use a real-time database of grid points computed by JPL's RTI (Real-Time Ionosphere) software. In both cases we evaluate the positional accuracy of a kinematic carrier phase based point positioning method on a global extent.

  1. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    NASA Astrophysics Data System (ADS)

    Brown, Shannon E.; Sargent, Steve; Wagner-Riddle, Claudia

    2018-03-01

    Nitrous oxide (N2O) fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2). The system features a relatively small, single-pass sample cell (200 mL) that provides good frequency response with a lower-powered pump ( ˜ 250 W). A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016) in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: -26.1 to 31.6 °C). The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz) and similar to that of a closed-path CO2 eddy-covariance system (4.05 Hz), using shorter tubing and no dryer, that was also collocated at the site. Values of the N2O fluxes were similar between the two spectrometer systems (slope = 1.01, r2 = 0.96); CO2 fluxes as measured by the short-tubed eddy-covariance system and the two spectrometer systems correlated well (slope = 1.03, r2 = 0.998). The new lower-powered tunable diode laser absorption spectrometer configuration with the filterless intake and single-tube dryer showed promise for deployment in remote areas.

  2. [Continuum based fast Fourier transform processing of infrared spectrum].

    PubMed

    Liu, Qing-Jie; Lin, Qi-Zhong; Wang, Qin-Jun; Li, Hui; Li, Shuai

    2009-12-01

    To recognize ground objects with infrared spectrum, high frequency noise removing is one of the most important phases in spectrum feature analysis and extraction. A new method for infrared spectrum preprocessing was given combining spectrum continuum processing and Fast Fourier Transform (CFFT). Continuum was firstly removed from the noise polluted infrared spectrum to standardize hyper-spectra. Then the spectrum was transformed into frequency domain (FD) with fast Fourier transform (FFT), separating noise information from target information After noise eliminating from useful information with a low-pass filter, the filtered FD spectrum was transformed into time domain (TD) with fast Fourier inverse transform. Finally the continuum was recovered to the spectrum, and the filtered infrared spectrum was achieved. Experiment was performed for chlorite spectrum in USGS polluted with two kinds of simulated white noise to validate the filtering ability of CFFT by contrast with cubic function of five point (CFFP) in time domain and traditional FFT in frequency domain. A circle of CFFP has limited filtering effect, so it should work much with more circles and consume more time to achieve better filtering result. As for conventional FFT, Gibbs phenomenon has great effect on preprocessing result at edge bands because of special character of rock or mineral spectra, while works well at middle bands. Mean squared error of CFFT is 0. 000 012 336 with cut-off frequency of 150, while that of FFT and CFFP is 0. 000 061 074 with cut-off frequency of 150 and 0.000 022 963 with 150 working circles respectively. Besides the filtering result of CFFT can be improved by adjusting the filter cut-off frequency, and has little effect on working time. The CFFT method overcomes the Gibbs problem of FFT in spectrum filtering, and can be more convenient, dependable, and effective than traditional TD filter methods.

  3. Method for removing RFI from SAR images

    DOEpatents

    Doerry, Armin W.

    2003-08-19

    A method of removing RFI from a SAR by comparing two SAR images on a pixel by pixel basis and selecting the pixel with the lower magnitude to form a composite image. One SAR image is the conventional image produced by the SAR. The other image is created from phase-history data which has been filtered to have the frequency bands containing the RFI removed.

  4. Systematic effects of foreground removal in 21-cm surveys of reionization

    NASA Astrophysics Data System (ADS)

    Petrovic, Nada; Oh, S. Peng

    2011-05-01

    21-cm observations have the potential to revolutionize our understanding of the high-redshift Universe. Whilst extremely bright radio continuum foregrounds exist at these frequencies, their spectral smoothness can be exploited to allow efficient foreground subtraction. It is well known that - regardless of other instrumental effects - this removes power on scales comparable to the survey bandwidth. We investigate associated systematic biases. We show that removing line-of-sight fluctuations on large scales aliases into suppression of the 3D power spectrum across a broad range of scales. This bias can be dealt with by correctly marginalizing over small wavenumbers in the 1D power spectrum; however, the unbiased estimator will have unavoidably larger variance. We also show that Gaussian realizations of the power spectrum permit accurate and extremely rapid Monte Carlo simulations for error analysis; repeated realizations of the fully non-Gaussian field are unnecessary. We perform Monte Carlo maximum likelihood simulations of foreground removal which yield unbiased, minimum variance estimates of the power spectrum in agreement with Fisher matrix estimates. Foreground removal also distorts the 21-cm probability distribution function (PDF), reducing the contrast between neutral and ionized regions, with potentially serious consequences for efforts to extract information from the PDF. We show that it is the subtraction of large-scale modes which is responsible for this distortion, and that it is less severe in the earlier stages of reionization. It can be reduced by using larger bandwidths. In the late stages of reionization, identification of the largest ionized regions (which consist of foreground emission only) provides calibration points which potentially allow recovery of large-scale modes. Finally, we also show that (i) the broad frequency response of synchrotron and free-free emission will smear out any features in the electron momentum distribution and ensure spectrally smooth foregrounds and (ii) extragalactic radio recombination lines should be negligible foregrounds.

  5. Empirical mode decomposition of the ECG signal for noise removal

    NASA Astrophysics Data System (ADS)

    Khan, Jesmin; Bhuiyan, Sharif; Murphy, Gregory; Alam, Mohammad

    2011-04-01

    Electrocardiography is a diagnostic procedure for the detection and diagnosis of heart abnormalities. The electrocardiogram (ECG) signal contains important information that is utilized by physicians for the diagnosis and analysis of heart diseases. So good quality ECG signal plays a vital role for the interpretation and identification of pathological, anatomical and physiological aspects of the whole cardiac muscle. However, the ECG signals are corrupted by noise which severely limit the utility of the recorded ECG signal for medical evaluation. The most common noise presents in the ECG signal is the high frequency noise caused by the forces acting on the electrodes. In this paper, we propose a new ECG denoising method based on the empirical mode decomposition (EMD). The proposed method is able to enhance the ECG signal upon removing the noise with minimum signal distortion. Simulation is done on the MIT-BIH database to verify the efficacy of the proposed algorithm. Experiments show that the presented method offers very good results to remove noise from the ECG signal.

  6. Atomic-level imaging, processing and characterization of semiconductor surfaces

    DOEpatents

    Kazmerski, Lawrence L.

    1995-01-01

    A method for selecting and removing single specific atoms from a solid material surface uses photon biasing to break down bonds that hold the selected atom in the lattice and to reduce barrier effects that hold the atom from transferring to a probe. The photon bias is preferably light or other electromagnetic radiation with a wavelength and frequency that approximately matches the wave function of the target atom species to be removed to induce high energy, selective thermionic-like vibration. An electric field potential is then applied between the probe and the surface of the solid material to pull the atom out of the lattice and to transfer the atom to the probe. Different extrinsic atoms can be installed in the lattice sites that are vacated by the removed atoms by using a photon bias that resonates the extrinsic atom species, reversing polarity of the electric field, and blowing gas comprising the extrinsic atoms through a hollow catheter probe.

  7. Atomic-level imaging, processing and characterization of semiconductor surfaces

    DOEpatents

    Kazmerski, L.L.

    1995-08-22

    A method for selecting and removing single specific atoms from a solid material surface uses photon biasing to break down bonds that hold the selected atom in the lattice and to reduce barrier effects that hold the atom from transferring to a probe. The photon bias is preferably light or other electromagnetic radiation with a wavelength and frequency that approximately matches the wave function of the target atom species to be removed to induce high energy, selective thermionic-like vibration. An electric field potential is then applied between the probe and the surface of the solid material to pull the atom out of the lattice and to transfer the atom to the probe. Different extrinsic atoms can be installed in the lattice sites that are vacated by the removed atoms by using a photon bias that resonates the extrinsic atom species, reversing polarity of the electric field, and blowing gas comprising the extrinsic atoms through a hollow catheter probe. 8 figs.

  8. Study on elimination of screening-current-induced field in pancake-type non-insulated HTS coil

    NASA Astrophysics Data System (ADS)

    Kim, K. L.; Song, J. B.; Yang, D. G.; Kim, Y. G.; Kim, T. H.; Kim, S. K.; Park, M. W.; Lee, H. G.

    2016-03-01

    This paper presents the details of a recent study on the removal of the screening-current-induced field (SCIF) in a pancake-type non-insulated high-temperature superconductor coil (NI coil). To determine the SCIF in the NI coil, the magnetic flux density (B z ) was calculated using the equivalent circuit model of the coil and compared to the B z obtained empirically. The experimental results indicate that the SCIF elimination in the NI coil was enhanced upon increasing the amplitude and frequency of the AC current being supplied to the background coil. Moreover, the SCIF in the NI coil was successfully removed by applying the appropriate external AC magnetic field intensity. This is because the magnetization direction of the SCIF changed completely from radial to spiral, a phenomenon termed the ‘vortex shaking effect.’ Overall, this study confirmed that the SCIF in a pancake-type NI coil can be effectively removed by exposing the coil to an external AC magnetic field.

  9. RAMONA-3B application to Browns Ferry ATWS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slovik, G.C.; Neymotin, L.Y.; Saha, P.

    1985-01-01

    The Anticipated Transient Without Scram (ATWS) is known to be a dominant accident sequence for possible core melt in a Boiling Water Reactor (BWR). A recent Probabilistic Risk Assessment (PRA) analysis for the Browns Ferry nuclear power plant indicates that ATWS is the second most dominant transient for core melt in BWR/4 with Mark I containment. The most dominant sequence being the failure of long term decay heat removal function of the Residual Heat Removal (RHR) system. Of all the various ATWS scenarios, the Main Steam Isolation Valve (MSIV) closure ATWS sequence was chosen for present analysis because of itsmore » relatively high frequency of occurrence and its challenge to the residual heat removal system and containment integrity. The objective of this paper is to discuss four MSIV closure ATWS calculations using the RAMONA-3B code. The paper is a summary of a report being prepared for the USNRC Severe Accident Sequence Analysis (SASA) program which should be referred to for details. 10 refs., 20 figs., 3 tabs.« less

  10. The NANOGrav 11-year Data Set: High-precision Timing of 45 Millisecond Pulsars

    NASA Astrophysics Data System (ADS)

    Arzoumanian, Zaven; Brazier, Adam; Burke-Spolaor, Sarah; Chamberlin, Sydney; Chatterjee, Shami; Christy, Brian; Cordes, James M.; Cornish, Neil J.; Crawford, Fronefield; Thankful Cromartie, H.; Crowter, Kathryn; DeCesar, Megan E.; Demorest, Paul B.; Dolch, Timothy; Ellis, Justin A.; Ferdman, Robert D.; Ferrara, Elizabeth C.; Fonseca, Emmanuel; Garver-Daniels, Nathan; Gentile, Peter A.; Halmrast, Daniel; Huerta, E. A.; Jenet, Fredrick A.; Jessup, Cody; Jones, Glenn; Jones, Megan L.; Kaplan, David L.; Lam, Michael T.; Lazio, T. Joseph W.; Levin, Lina; Lommen, Andrea; Lorimer, Duncan R.; Luo, Jing; Lynch, Ryan S.; Madison, Dustin; Matthews, Allison M.; McLaughlin, Maura A.; McWilliams, Sean T.; Mingarelli, Chiara; Ng, Cherry; Nice, David J.; Pennucci, Timothy T.; Ransom, Scott M.; Ray, Paul S.; Siemens, Xavier; Simon, Joseph; Spiewak, Renée; Stairs, Ingrid H.; Stinebring, Daniel R.; Stovall, Kevin; Swiggum, Joseph K.; Taylor, Stephen R.; Vallisneri, Michele; van Haasteren, Rutger; Vigeland, Sarah J.; Zhu, Weiwei; The NANOGrav Collaboration

    2018-04-01

    We present high-precision timing data over time spans of up to 11 years for 45 millisecond pulsars observed as part of the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) project, aimed at detecting and characterizing low-frequency gravitational waves. The pulsars were observed with the Arecibo Observatory and/or the Green Bank Telescope at frequencies ranging from 327 MHz to 2.3 GHz. Most pulsars were observed with approximately monthly cadence, and six high-timing-precision pulsars were observed weekly. All were observed at widely separated frequencies at each observing epoch in order to fit for time-variable dispersion delays. We describe our methods for data processing, time-of-arrival (TOA) calculation, and the implementation of a new, automated method for removing outlier TOAs. We fit a timing model for each pulsar that includes spin, astrometric, and (for binary pulsars) orbital parameters; time-variable dispersion delays; and parameters that quantify pulse-profile evolution with frequency. The timing solutions provide three new parallax measurements, two new Shapiro delay measurements, and two new measurements of significant orbital-period variations. We fit models that characterize sources of noise for each pulsar. We find that 11 pulsars show significant red noise, with generally smaller spectral indices than typically measured for non-recycled pulsars, possibly suggesting a different origin. A companion paper uses these data to constrain the strength of the gravitational-wave background.

  11. When the Ostrich-Algorithm Fails: Blanking Method Affects Spike Train Statistics.

    PubMed

    Joseph, Kevin; Mottaghi, Soheil; Christ, Olaf; Feuerstein, Thomas J; Hofmann, Ulrich G

    2018-01-01

    Modern electroceuticals are bound to employ the usage of electrical high frequency (130-180 Hz) stimulation carried out under closed loop control, most prominent in the case of movement disorders. However, particular challenges are faced when electrical recordings of neuronal tissue are carried out during high frequency electrical stimulation, both in-vivo and in-vitro . This stimulation produces undesired artifacts and can render the recorded signal only partially useful. The extent of these artifacts is often reduced by temporarily grounding the recording input during stimulation pulses. In the following study, we quantify the effects of this method, "blanking," on the spike count and spike train statistics. Starting from a theoretical standpoint, we calculate a loss in the absolute number of action potentials, depending on: width of the blanking window, frequency of stimulation, and intrinsic neuronal activity. These calculations were then corroborated by actual high signal to noise ratio (SNR) single cell recordings. We state that, for clinically relevant frequencies of 130 Hz (used for movement disorders) and realistic blanking windows of 2 ms, up to 27% of actual existing spikes are lost. We strongly advice cautioned use of the blanking method when spike rate quantification is attempted. Blanking (artifact removal by temporarily grounding input), depending on recording parameters, can lead to significant spike loss. Very careful use of blanking circuits is advised.

  12. When the Ostrich-Algorithm Fails: Blanking Method Affects Spike Train Statistics

    PubMed Central

    Joseph, Kevin; Mottaghi, Soheil; Christ, Olaf; Feuerstein, Thomas J.; Hofmann, Ulrich G.

    2018-01-01

    Modern electroceuticals are bound to employ the usage of electrical high frequency (130–180 Hz) stimulation carried out under closed loop control, most prominent in the case of movement disorders. However, particular challenges are faced when electrical recordings of neuronal tissue are carried out during high frequency electrical stimulation, both in-vivo and in-vitro. This stimulation produces undesired artifacts and can render the recorded signal only partially useful. The extent of these artifacts is often reduced by temporarily grounding the recording input during stimulation pulses. In the following study, we quantify the effects of this method, “blanking,” on the spike count and spike train statistics. Starting from a theoretical standpoint, we calculate a loss in the absolute number of action potentials, depending on: width of the blanking window, frequency of stimulation, and intrinsic neuronal activity. These calculations were then corroborated by actual high signal to noise ratio (SNR) single cell recordings. We state that, for clinically relevant frequencies of 130 Hz (used for movement disorders) and realistic blanking windows of 2 ms, up to 27% of actual existing spikes are lost. We strongly advice cautioned use of the blanking method when spike rate quantification is attempted. Impact statement Blanking (artifact removal by temporarily grounding input), depending on recording parameters, can lead to significant spike loss. Very careful use of blanking circuits is advised. PMID:29780301

  13. Cowbird removals unexpectedly increase productivity of a brood parasite and the songbird host.

    PubMed

    Kosciuch, Karl L; Sandercock, Brett K

    2008-03-01

    Generalist brood parasites reduce productivity and population growth of avian hosts and have been implicated in population declines of several songbirds of conservation concern. To estimate the demographic effects of brood parasitism on Bell's Vireos (Vireo bellii), we removed Brown-headed Cowbirds (Molothrus ater) in a replicated switchback experimental design. Cowbird removals decreased parasitism frequency from 77% and 85% at unmanipulated plots to 58% and 47% at removal plots in 2004 and 2005, respectively. Vireo productivity per pair was higher at cowbird removal plots when years were pooled (mean = 2.6 +/- 0.2 [SE] young per pair) compared to unmanipulated plots (1.2 +/- 0.1). Nest desertion frequency was lower at cowbird removal plots (35% of parasitized nests) compared to unmanipulated plots (69%) because removal of host eggs was the proximate cue for nest desertion, and vireos experienced lower rates of egg loss at cowbird removal plots. Nest success was higher among unparasitized than parasitized nests, and parasitized nests at cowbird removal plots had a higher probability of success than parasitized nests at unmanipulated plots. Unexpectedly, cowbird productivity from vireo pairs was higher at cowbird removal plots (mean = 0.3 +/- 0.06 young per pair) than at unmanipulated plots (0.1 +/- 0.03) because fewer parasitized nests were deserted and the probability of nest success was higher. Our study provides the first evidence that increases in cowbird productivity may be an unintended consequence of cowbird control programs, especially during the initial years of trapping when parasitism may only be moderately reduced. Thus, understanding the demographic impacts of cowbird removals requires an informed understanding of the behavioral ecology of host-parasite interactions.

  14. Imaging surface nanobubbles at graphite-water interfaces with different atomic force microscopy modes.

    PubMed

    Yang, Chih-Wen; Lu, Yi-Hsien; Hwang, Ing-Shouh

    2013-05-08

    We have imaged nanobubbles on highly ordered pyrolytic graphite (HOPG) surfaces in pure water with different atomic force microscopy (AFM) modes, including the frequency-modulation, the tapping, and the PeakForce techniques. We have compared the performance of these modes in obtaining the surface profiles of nanobubbles. The frequency-modulation mode yields a larger height value than the other two modes and can provide more accurate measurement of the surface profiles of nanobubbles. Imaging with PeakForce mode shows that a nanobubble appears smaller and shorter with increasing peak force and disappears above a certain peak force, but the size returns to the original value when the peak force is reduced. This indicates that imaging with high peak forces does not cause gas removal from the nanobubbles. Based on the presented findings and previous AFM observations, the existing models for nanobubbles are reviewed and discussed. The model of gas aggregate inside nanobubbles provides a better explanation for the puzzles of the high stability and the contact angle of surface nanobubbles.

  15. Ab-initio study of high temperature lattice dynamics of BCC zirconium (β-Zr) and uranium (γ-U)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, Partha S., E-mail: parthasarathi13@gmail.com; Arya, A., E-mail: parthasarathi13@gmail.com; Dey, G. K., E-mail: parthasarathi13@gmail.com

    2014-04-24

    Using self consistent ab-initio lattice dynamics calculations, we show that bcc structures of Zr and U phases become stable at high temperature by phonon-phonon interactions. The calculated temperature dependent phonon dispersion curve (PDC) of β-Zr match excellently with experimental PDC. But the calculated PDC for γ-U shows negative phonon frequencies even at solid to liquid transition temperature. We show that this discrepancy is due to an overestimation of instability depth of bcc U phase which is removed by incorporation of spin-orbit coupling in the electronic structure calculations.

  16. Removing the Impact of Correlated PSF Uncertainties in Weak Lensing

    NASA Astrophysics Data System (ADS)

    Lu, Tianhuan; Zhang, Jun; Dong, Fuyu; Li, Yingke; Liu, Dezi; Fu, Liping; Li, Guoliang; Fan, Zuhui

    2018-05-01

    Accurate reconstruction of the spatial distributions of the point-spread function (PSF) is crucial for high precision cosmic shear measurements. Nevertheless, current methods are not good at recovering the PSF fluctuations of high spatial frequencies. In general, the residual PSF fluctuations are spatially correlated, and therefore can significantly contaminate the correlation functions of the weak lensing signals. We propose a method to correct for this contamination statistically, without any assumptions on the PSF and galaxy morphologies or their spatial distribution. We demonstrate our idea with the data from the W2 field of CFHTLenS.

  17. Laser Ablation of Dental Calculus Around 400 nm Using a Ti:Sapphire Laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenly, J.; Seka, W.; Rechmann, P.

    2009-10-19

    A Nd:YAG laser-pumped, frequency-doubled Ti:sapphire laser is used for selective ablation of calculus. The laser provides ≤25 mJ at 400 nm (60-ns pulse width, 10-Hz repetition rate). The laser is coupled into an optical multimode fiber coiled around a 4-in.-diam drum to generate a top-hat output intensity profile. With coaxial water cooling, this is ideal for efficient, selective calculus removal. This is in stark contrast with tightly focused Gaussian beams that are energetically inefficient and lead to irreproducible results. Calculus is well ablated at high fluences ≥2 J/cm^2; stalling occurs below this fluence because of photobleaching. Healthy hard tissue ismore » not removed at fluences ≤3 J/cm^2.« less

  18. Flight testing of live Monarch butterflies to determine the aerodynamic benefit of butterfly scales

    NASA Astrophysics Data System (ADS)

    Lang, Amy; Cranford, Jacob; Conway, Jasmine; Slegers, Nathan; Dechello, Nicole; Wilroy, Jacob

    2014-11-01

    Evolutionary adaptations in the morphological structure of butterfly scales (0.1 mm in size) to develop a unique micro-patterning resulting in a surface drag alteration, stem from a probable aerodynamic benefit of minimizing the energy requirement to fly a very lightweight body with comparably large surface area in a low Re flow regime. Live Monarch butterflies were tested at UAHuntsville's Autonomous Tracking and Optical Measurement (ATOM) Laboratory, which uses 22 Vicon T40 cameras that allow for millimeter level tracking of reflective markers at 515 fps over a 4 m × 6 m × 7 m volume. Data recorded included the flight path as well as the wing flapping angle and wing-beat frequency. Insects were first tested with their scales intact, and then again with the scales carefully removed. Differences in flapping frequency and/or energy obtained during flight due to the removal of the scales will be discussed. Initial data analysis indicates that scale removal in some specimens leads to increased flapping frequencies for similar energetic flight or reduced flight speed for similar flapping frequencies. Both results point to the scales providing an aerodynamic benefit, which is hypothesized to be linked to leading-edge vortex formation and induced drag. Funding from the National Science Foundation (CBET and REU) is gratefully acknowledged.

  19. A Computationally Efficient Method for Polyphonic Pitch Estimation

    NASA Astrophysics Data System (ADS)

    Zhou, Ruohua; Reiss, Joshua D.; Mattavelli, Marco; Zoia, Giorgio

    2009-12-01

    This paper presents a computationally efficient method for polyphonic pitch estimation. The method employs the Fast Resonator Time-Frequency Image (RTFI) as the basic time-frequency analysis tool. The approach is composed of two main stages. First, a preliminary pitch estimation is obtained by means of a simple peak-picking procedure in the pitch energy spectrum. Such spectrum is calculated from the original RTFI energy spectrum according to harmonic grouping principles. Then the incorrect estimations are removed according to spectral irregularity and knowledge of the harmonic structures of the music notes played on commonly used music instruments. The new approach is compared with a variety of other frame-based polyphonic pitch estimation methods, and results demonstrate the high performance and computational efficiency of the approach.

  20. Resonance-induced sensitivity enhancement method for conductivity sensors

    NASA Technical Reports Server (NTRS)

    Tai, Yu-Chong (Inventor); Shih, Chi-yuan (Inventor); Li, Wei (Inventor); Zheng, Siyang (Inventor)

    2009-01-01

    Methods and systems for improving the sensitivity of a variety of conductivity sensing devices, in particular capacitively-coupled contactless conductivity detectors. A parallel inductor is added to the conductivity sensor. The sensor with the parallel inductor is operated at a resonant frequency of the equivalent circuit model. At the resonant frequency, parasitic capacitances that are either in series or in parallel with the conductance (and possibly a series resistance) is substantially removed from the equivalent circuit, leaving a purely resistive impedance. An appreciably higher sensor sensitivity results. Experimental verification shows that sensitivity improvements of the order of 10,000-fold are possible. Examples of detecting particulates with high precision by application of the apparatus and methods of operation are described.

  1. Computational multiheterodyne spectroscopy

    PubMed Central

    Burghoff, David; Yang, Yang; Hu, Qing

    2016-01-01

    Dual-comb spectroscopy allows for high-resolution spectra to be measured over broad bandwidths, but an essential requirement for coherent integration is the availability of a phase reference. Usually, this means that the combs’ phase and timing errors must be measured and either minimized by stabilization or removed by correction, limiting the technique’s applicability. We demonstrate that it is possible to extract the phase and timing signals of a multiheterodyne spectrum completely computationally, without any extra measurements or optical elements. These techniques are viable even when the relative linewidth exceeds the repetition rate difference and can tremendously simplify any dual-comb system. By reconceptualizing frequency combs in terms of the temporal structure of their phase noise, not their frequency stability, we can greatly expand the scope of multiheterodyne techniques. PMID:27847870

  2. Spectral analysis and filtering techniques in digital spatial data processing

    USGS Publications Warehouse

    Pan, Jeng-Jong

    1989-01-01

    A filter toolbox has been developed at the EROS Data Center, US Geological Survey, for retrieving or removing specified frequency information from two-dimensional digital spatial data. This filter toolbox provides capabilities to compute the power spectrum of a given data and to design various filters in the frequency domain. Three types of filters are available in the toolbox: point filter, line filter, and area filter. Both the point and line filters employ Gaussian-type notch filters, and the area filter includes the capabilities to perform high-pass, band-pass, low-pass, and wedge filtering techniques. These filters are applied for analyzing satellite multispectral scanner data, airborne visible and infrared imaging spectrometer (AVIRIS) data, gravity data, and the digital elevation models (DEM) data. -from Author

  3. Electromagnetic confinement and movement of thin sheets of molten metal

    DOEpatents

    Lari, Robert J.; Praeg, Walter F.; Turner, Larry R.

    1990-01-01

    An apparatus capable of producing a combination of magnetic fields that can retain a metal in liquid form in a region having a smooth vertical boundary including a levitation magnet that produces low frequency magnetic field traveling waves to retain the metal and a stabilization magnet that produces a high frequency magnetic field to produce a smooth vertical boundary. As particularly adapted to the casting of solid metal sheets, a metal in liquid form can be continuously fed into one end of the confinement region produced by the levitation and stabilization magnets and removed in solid form from the other end of confinement region. An additional magnet may be included for support at the edges of the confinement region where eddy currents loop.

  4. Enhancing chemical reactions

    DOEpatents

    Morrey, John R.

    1978-01-01

    Methods of enhancing selected chemical reactions. The population of a selected high vibrational energy state of a reactant molecule is increased substantially above its population at thermal equilibrium by directing onto the molecule a beam of radiant energy from a laser having a combination of frequency and intensity selected to pump the selected energy state, and the reaction is carried out with the temperature, pressure, and concentrations of reactants maintained at a combination of values selected to optimize the reaction in preference to thermal degradation by transforming the absorbed energy into translational motion. The reaction temperature is selected to optimize the reaction. Typically a laser and a frequency doubler emit radiant energy at frequencies of .nu. and 2.nu. into an optical dye within an optical cavity capable of being tuned to a wanted frequency .delta. or a parametric oscillator comprising a non-centrosymmetric crystal having two indices of refraction, to emit radiant energy at the frequencies of .nu., 2.nu., and .delta. (and, with a parametric oscillator, also at 2.nu.-.delta.). Each unwanted frequency is filtered out, and each desired frequency is focused to the desired radiation flux within a reaction chamber and is reflected repeatedly through the chamber while reactants are fed into the chamber and reaction products are removed therefrom.

  5. Effects of Long-Term Speech-in-Noise Training in Air Traffic Controllers and High Frequency Suppression. A Control Group Study.

    PubMed

    Pérez Zaballos, María Teresa; Ramos de Miguel, Ángel; Pérez Plasencia, Daniel; Zaballos González, María Luisa; Ramos Macías, Ángel

    2015-12-01

    To evaluate 1) if air traffic controllers (ATC) perform better than non-air traffic controllers in an open-set speech-in-noise test because of their experience with radio communications, and 2) if high-frequency information (>8000 Hz) substantially improves speech-in-noise perception across populations. The control group comprised 28 normal-hearing subjects, and the target group comprised 48 ATCs aged between 19 and 55 years who were native Spanish speakers. The hearing -in-noise abilities of the two groups were characterized under two signal conditions: 1) speech tokens and white noise sampled at 44.1 kHz (unfiltered condition) and 2) speech tokens plus white noise, each passed through a 4th order Butterworth filter with 70 and 8000 Hz low and high cutoffs (filtered condition). These tests were performed at signal-to-noise ratios of +5, 0, and -5-dB SNR. The ATCs outperformed the control group in all conditions. The differences were statistically significant in all cases, and the largest difference was observed under the most difficult conditions (-5 dB SNR). Overall, scores were higher when high-frequency components were not suppressed for both groups, although statistically significant differences were not observed for the control group at 0 dB SNR. The results indicate that ATCs are more capable of identifying speech in noise. This may be due to the effect of their training. On the other hand, performance seems to decrease when the high frequency components of speech are removed, regardless of training.

  6. Removing the regional level from the Niger vaccine supply chain.

    PubMed

    Assi, Tina-Marie; Brown, Shawn T; Kone, Souleymane; Norman, Bryan A; Djibo, Ali; Connor, Diana L; Wateska, Angela R; Rajgopal, Jayant; Slayton, Rachel B; Lee, Bruce Y

    2013-06-10

    Since many of the world's vaccine supply chains contain multiple levels, the question remains of whether removing a level could bring efficiencies. We utilized HERMES to generate a detailed discrete-event simulation model of Niger's vaccine supply chain and compared the current four-tier (central, regional, district, and integrated health center levels) with a modified three-tier structure (removing the regional level). Different scenarios explored various accompanying shipping policies and frequencies. Removing the regional level and implementing a collection-based shipping policy from the district stores increases vaccine availability from a mean of 70-100% when districts could collect vaccines at least weekly. Alternatively, implementing a delivery-based shipping policy from the central store monthly in three-route and eight-route scenarios only increases vaccine availability to 87%. Restricting central-to district vaccine shipments to a quarterly schedule for three-route and eight-route scenarios reduces vaccine availability to 49%. The collection-based shipping policy from district stores reduces supply chain logistics cost per dose administered from US$0.14 at baseline to US$0.13 after removing the regional level. Removing the regional level from Niger's vaccine supply chain can substantially improve vaccine availability as long as certain concomitant adjustments to shipping policies and frequencies are implemented. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Removing the Regional Level from the Niger Vaccine Supply Chain

    PubMed Central

    Assi, Tina-Marie; Brown, Shawn T.; Kone, Souleymane; Norman, Bryan A.; Djibo, Ali; Connor, Diana L.; Wateska, Angela R.; Rajgopal, Jayant; Slayton, Rachel B.; Lee, Bruce Y.

    2013-01-01

    Objective Since many of the world’s vaccine supply chains contain multiple levels, the question remains of whether removing a level could bring efficiencies. Methods We utilized HERMES to generate a detailed discrete-event simulation model of Niger’s vaccine supply chain and compare the current four-tier (central, regional, district and integrated health center levels) with a modified three-tier structure (removing the regional level). Different scenarios explored various accompanying shipping policies and frequencies. Findings Removing the regional level and implementing a collection-based shipping policy from the district stores increases vaccine availability from a mean of 70% to 100% when districts could collect vaccines at least weekly. Alternatively, implementing a delivery-based shipping policy from the central store monthly in three-route and eight-route scenarios only increases vaccine availability to 87%. Restricting central-to district vaccine shipments to a quarterly schedule for three-route and eight-route scenarios reduces vaccine availability to 49%. The collection-based shipping policy from district stores reduces supply chain logistics cost per dose administered from US$0.14 at baseline to US$0.13 after removing the regional level. Conclusion Removing the regional level from Niger’s vaccine supply chain can substantially improve vaccine availability as long as certain concomitant adjustments to shipping policies and frequencies are implemented. PMID:23602666

  8. Indoor air purification by dielectric barrier discharge combined with ionic wind: physical and microbiological investigations

    NASA Astrophysics Data System (ADS)

    Timmermann, E.; Prehn, F.; Schmidt, M.; Höft, H.; Brandenburg, R.; Kettlitz, M.

    2018-04-01

    A non-thermal plasma source based on a surface dielectric barrier discharge (DBD) is developed for purification of recirculating air in operating theatres in hospitals. This is a challenging application due to high flow rates, short treatment times and the low threshold for ozone in the ventilated air. Therefore, the surface DBD was enhanced in order to generate an ionic wind, which can deflect and thus, filter out airborne microorganisms. Electrical and gas diagnostics as well as microbiological experiments were performed in a downscaled plasma source under variation of various electrical parameters, but application-oriented airflow velocity and humidity. The dependence of electrical power and ozone concentration as well as charged particles in the plasma treated air on frequency, voltage and relative humidity is presented and discussed. The presence of humidity causes a more conductive dielectric surface and thus a weaker plasma formation, especially at low frequency. The airborne test bacteria, Escherichia coli, showed significant effect to plasma treatment (up to 20% reduction) and to plasma with ionic wind (up to 90% removal); especially a configuration with 70% removal and an accompanying ozone concentration of only 360 ppb is promising for future application.

  9. Structure, temperature and frequency dependent electrical conductivity of oxidized and reduced electrochemically exfoliated graphite

    NASA Astrophysics Data System (ADS)

    Radoń, Adrian; Włodarczyk, Patryk; Łukowiec, Dariusz

    2018-05-01

    The article presents the influence of reduction by hydrogen in statu nascendi and modification by hydrogen peroxide on the structure and electrical conductivity of electrochemically exfoliated graphite. It was confirmed that the electrochemical exfoliation can be used to produce oxidized nanographite with an average number of 25 graphene layers. The modified electrochemical exfoliated graphite and reduced electrochemical exfoliated graphite were characterized by high thermal stability, what was associated with removing of labile oxygen-containing groups. The presence of oxygen-containing groups was confirmed using Fourier-transform infrared spectroscopy. Influence of chemical modification by hydrogen and hydrogen peroxide on the electrical conductivity was determined in wide frequency (0.1 Hz-10 kHz) and temperature range (-50 °C-100 °C). Material modified by hydrogen peroxide (0.29 mS/cm at 0 °C) had the lowest electrical conductivity. This can be associated with oxidation of unstable functional groups and was also confirmed by analysis of Raman spectra. The removal of oxygen-containing functional groups by hydrogen in statu nascendi resulted in a 1000-fold increase in the electrical conductivity compared to the electrochemical exfoliated graphite.

  10. Screening and prioritization of micropollutants in wastewaters from on-site sewage treatment facilities.

    PubMed

    Gros, Meritxell; Blum, Kristin M; Jernstedt, Henrik; Renman, Gunno; Rodríguez-Mozaz, Sara; Haglund, Peter; Andersson, Patrik L; Wiberg, Karin; Ahrens, Lutz

    2017-04-15

    A comprehensive screening of micropollutants was performed in wastewaters from on-site sewage treatment facilities (OSSFs) and urban wastewater treatment plants (WWTPs) in Sweden. A suspect screening approach, using high resolution mass spectrometry, was developed and used in combination with target analysis. With this strategy, a total number of 79 micropollutants were successfully identified, which belong to the groups of per- and polyfluoroalkyl substances (PFASs), pesticides, phosphorus-containing flame retardants (PFRs) and pharmaceuticals and personal care products (PPCPs). Results from this screening indicate that concentrations of micropollutants are similar in influents and effluents of OSSFs and WWTPs, respectively. Removal efficiencies of micropollutants were assessed in the OSSFs and compared with those observed in WWTPs. In general, removal of PFASs and PFRs was higher in package treatment OSSFs, which are based on biological treatments, while removal of PPCPs was more efficient in soil bed OSSFs. A novel comprehensive prioritization strategy was then developed to identify OSSF specific chemicals of environmental relevance. The strategy was based on the compound concentrations in the wastewater, removal efficiency, frequency of detection in OSSFs and on in silico based data for toxicity, persistency and bioaccumulation potential. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Solving the Capacitive Effect in the High-Frequency sweep for Langmuir Probe in SYMPLE

    NASA Astrophysics Data System (ADS)

    Pramila; Patel, J. J.; Rajpal, R.; Hansalia, C. J.; Anitha, V. P.; Sathyanarayana, K.

    2017-04-01

    Langmuir Probe based measurements need to be routinely carried out to measure various plasma parameters such as the electron density (ne), the electron temperature (Te), the floating potential (Vf), and the plasma potential (Vp). For this, the diagnostic electronics along with the biasing power supplies is installed in standard industrial racks with a 2KV isolation transformer. The Signal Conditioning Electronics (SCE) system is populated inside the 4U-chassis based system with the front-end electronics, designed using high common mode differential amplifiers which can measure small differential signal in presence of high common mode dc- bias or ac ramp voltage used for biasing the probes. DC-biasing of the probe is most common method for getting its I-V characteristic but method of biasing the probe with a sweep at high frequency encounters the problem of corruption of signal due to capacitive effect specially when the sweep period and the discharge time is very fast and die down in the order of μs or lesser. This paper presents and summarises the method of removing such effects encountered while measuring the probe current.

  12. THE APPLICATION OF MULTIVIEW METHODS FOR HIGH-PRECISION ASTROMETRIC SPACE VLBI AT LOW FREQUENCIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodson, R.; Rioja, M.; Imai, H.

    2013-06-15

    High-precision astrometric space very long baseline interferometry (S-VLBI) at the low end of the conventional frequency range, i.e., 20 cm, is a requirement for a number of high-priority science goals. These are headlined by obtaining trigonometric parallax distances to pulsars in pulsar-black hole pairs and OH masers anywhere in the Milky Way and the Magellanic Clouds. We propose a solution for the most difficult technical problems in S-VLBI by the MultiView approach where multiple sources, separated by several degrees on the sky, are observed simultaneously. We simulated a number of challenging S-VLBI configurations, with orbit errors up to 8 mmore » in size and with ionospheric atmospheres consistent with poor conditions. In these simulations we performed MultiView analysis to achieve the required science goals. This approach removes the need for beam switching requiring a Control Moment Gyro, and the space and ground infrastructure required for high-quality orbit reconstruction of a space-based radio telescope. This will dramatically reduce the complexity of S-VLBI missions which implement the phase-referencing technique.« less

  13. Measuring the Levels of Ribonucleotides Embedded in Genomic DNA.

    PubMed

    Meroni, Alice; Nava, Giulia M; Sertic, Sarah; Plevani, Paolo; Muzi-Falconi, Marco; Lazzaro, Federico

    2018-01-01

    Ribonucleotides (rNTPs) are incorporated into genomic DNA at a relatively high frequency during replication. They have beneficial effects but, if not removed from the chromosomes, increase genomic instability. Here, we describe a fast method to easily estimate the amounts of embedded ribonucleotides into the genome. The protocol described is performed in Saccharomyces cerevisiae and allows us to quantify altered levels of rNMPs due to different mutations in the replicative polymerase ε. However, this protocol can be easily applied to cells derived from any organism.

  14. Reusable hydroxyapatite nanocrystal sensors for protein adsorption.

    PubMed

    Tagaya, Motohiro; Ikoma, Toshiyuki; Hanagata, Nobutaka; Chakarov, Dinko; Kasemo, Bengt; Tanaka, Junzo

    2010-08-01

    The repeatability of the adsorption and removal of fibrinogen and fetal bovine serum on hydroxyapatite (HAp) nanocrystal sensors was investigated by Fourier transform infrared (FTIR) spectroscopy and quartz crystal microbalance with dissipation (QCM-D) monitoring technique. The HAp nanocrystals were coated on a gold-coated quartz sensor by electrophoretic deposition. Proteins adsorbed on the HAp sensors were removed by (i) ammonia/hydrogen peroxide mixture (APM), (ii) ultraviolet light (UV), (iii) UV/APM, (iv) APM/UV and (v) sodium dodecyl sulfate (SDS) treatments. FTIR spectra of the reused surfaces revealed that the APM and SDS treatments left peptide fragments or the proteins adsorbed on the surfaces, whereas the other methods successfully removed the proteins. The QCM-D measurements indicated that in the removal treatments, fibrinogen was slowly adsorbed in the first cycle because of the change in surface wettability revealed by contact angle measurements. The SDS treatment was not effective in removing proteins. The APM or UV treatment decreased the frequency shifts for the reused HAp sensors. The UV/APM treatment did not induce the frequency shifts but decreased the dissipation shifts. Therefore, we conclude that the APM/UV treatment is the most useful method for reproducing protein adsorption behavior on HAp sensors.

  15. Reusable hydroxyapatite nanocrystal sensors for protein adsorption

    NASA Astrophysics Data System (ADS)

    Tagaya, Motohiro; Ikoma, Toshiyuki; Hanagata, Nobutaka; Chakarov, Dinko; Kasemo, Bengt; Tanaka, Junzo

    2010-08-01

    The repeatability of the adsorption and removal of fibrinogen and fetal bovine serum on hydroxyapatite (HAp) nanocrystal sensors was investigated by Fourier transform infrared (FTIR) spectroscopy and quartz crystal microbalance with dissipation (QCM-D) monitoring technique. The HAp nanocrystals were coated on a gold-coated quartz sensor by electrophoretic deposition. Proteins adsorbed on the HAp sensors were removed by (i) ammonia/hydrogen peroxide mixture (APM), (ii) ultraviolet light (UV), (iii) UV/APM, (iv) APM/UV and (v) sodium dodecyl sulfate (SDS) treatments. FTIR spectra of the reused surfaces revealed that the APM and SDS treatments left peptide fragments or the proteins adsorbed on the surfaces, whereas the other methods successfully removed the proteins. The QCM-D measurements indicated that in the removal treatments, fibrinogen was slowly adsorbed in the first cycle because of the change in surface wettability revealed by contact angle measurements. The SDS treatment was not effective in removing proteins. The APM or UV treatment decreased the frequency shifts for the reused HAp sensors. The UV/APM treatment did not induce the frequency shifts but decreased the dissipation shifts. Therefore, we conclude that the APM/UV treatment is the most useful method for reproducing protein adsorption behavior on HAp sensors.

  16. Scalable process for mitigation of laser-damaged potassium dihydrogen phosphate crystal optic surfaces with removal of damaged antireflective coating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elhadj, S.; Steele, W. A.; VanBlarcom, D. S.

    Here, we investigate an approach for the recycling of laser-damaged large-aperture deuterated potassium dihydrogen phosphate (DKDP) crystals used for optical switching (KDP) and for frequency conversion (DKDP) in megajoule-class high-power laser systems. The approach consists of micromachining the surface laser damage sites (mitigation), combined with multiple soaks and ultrasonication steps in a coating solvent to remove, synergistically, both the highly adherent machining debris and the laser-damage-affected antireflection coating. We then identify features of the laser-damage-affected coating, such as the “solvent-persistent” coating and the “burned-in” coating, that are difficult to remove by conventional approaches without damaging the surface. We also providemore » a solution to the erosion problem identified in this work when colloidal coatings are processed during ultrasonication. Finally, we provide a proof of principle of the approach by testing the full process that includes laser damage mitigation of DKDP test parts, coat stripping, reapplication of a new antireflective coat, and a laser damage test demonstrating performance up to at least 12 J/cm 2 at UV wavelengths, which is well above current requirements. Our approach ultimately provides a potential path to a scalable recycling loop for the management of optics in large, high-power laser systems that can reduce cost and extend lifetime of highly valuable and difficult to grow large DKDP crystals.« less

  17. Scalable process for mitigation of laser-damaged potassium dihydrogen phosphate crystal optic surfaces with removal of damaged antireflective coating

    DOE PAGES

    Elhadj, S.; Steele, W. A.; VanBlarcom, D. S.; ...

    2017-03-07

    Here, we investigate an approach for the recycling of laser-damaged large-aperture deuterated potassium dihydrogen phosphate (DKDP) crystals used for optical switching (KDP) and for frequency conversion (DKDP) in megajoule-class high-power laser systems. The approach consists of micromachining the surface laser damage sites (mitigation), combined with multiple soaks and ultrasonication steps in a coating solvent to remove, synergistically, both the highly adherent machining debris and the laser-damage-affected antireflection coating. We then identify features of the laser-damage-affected coating, such as the “solvent-persistent” coating and the “burned-in” coating, that are difficult to remove by conventional approaches without damaging the surface. We also providemore » a solution to the erosion problem identified in this work when colloidal coatings are processed during ultrasonication. Finally, we provide a proof of principle of the approach by testing the full process that includes laser damage mitigation of DKDP test parts, coat stripping, reapplication of a new antireflective coat, and a laser damage test demonstrating performance up to at least 12 J/cm 2 at UV wavelengths, which is well above current requirements. Our approach ultimately provides a potential path to a scalable recycling loop for the management of optics in large, high-power laser systems that can reduce cost and extend lifetime of highly valuable and difficult to grow large DKDP crystals.« less

  18. Doppler-based motion compensation algorithm for focusing the signature of a rotorcraft.

    PubMed

    Goldman, Geoffrey H

    2013-02-01

    A computationally efficient algorithm was developed and tested to compensate for the effects of motion on the acoustic signature of a rotorcraft. For target signatures with large spectral peaks that vary slowly in amplitude and have near constant frequency, the time-varying Doppler shift can be tracked and then removed from the data. The algorithm can be used to preprocess data for classification, tracking, and nulling algorithms. The algorithm was tested on rotorcraft data. The average instantaneous frequency of the first harmonic of a rotorcraft was tracked with a fixed-lag smoother. Then, state space estimates of the frequency were used to calculate a time warping that removed the effect of a time-varying Doppler shift from the data. The algorithm was evaluated by analyzing the increase in the amplitude of the harmonics in the spectrum of a rotorcraft. The results depended upon the frequency of the harmonics and the processing interval duration. Under good conditions, the results for the fundamental frequency of the target (~11 Hz) almost achieved an estimated upper bound. The results for higher frequency harmonics had larger increases in the amplitude of the peaks, but significantly lower than the estimated upper bounds.

  19. Improved Goldstein Interferogram Filter Based on Local Fringe Frequency Estimation.

    PubMed

    Feng, Qingqing; Xu, Huaping; Wu, Zhefeng; You, Yanan; Liu, Wei; Ge, Shiqi

    2016-11-23

    The quality of an interferogram, which is limited by various phase noise, will greatly affect the further processes of InSAR, such as phase unwrapping. Interferometric SAR (InSAR) geophysical measurements', such as height or displacement, phase filtering is therefore an essential step. In this work, an improved Goldstein interferogram filter is proposed to suppress the phase noise while preserving the fringe edges. First, the proposed adaptive filter step, performed before frequency estimation, is employed to improve the estimation accuracy. Subsequently, to preserve the fringe characteristics, the estimated fringe frequency in each fixed filtering patch is removed from the original noisy phase. Then, the residual phase is smoothed based on the modified Goldstein filter with its parameter alpha dependent on both the coherence map and the residual phase frequency. Finally, the filtered residual phase and the removed fringe frequency are combined to generate the filtered interferogram, with the loss of signal minimized while reducing the noise level. The effectiveness of the proposed method is verified by experimental results based on both simulated and real data.

  20. Improved Goldstein Interferogram Filter Based on Local Fringe Frequency Estimation

    PubMed Central

    Feng, Qingqing; Xu, Huaping; Wu, Zhefeng; You, Yanan; Liu, Wei; Ge, Shiqi

    2016-01-01

    The quality of an interferogram, which is limited by various phase noise, will greatly affect the further processes of InSAR, such as phase unwrapping. Interferometric SAR (InSAR) geophysical measurements’, such as height or displacement, phase filtering is therefore an essential step. In this work, an improved Goldstein interferogram filter is proposed to suppress the phase noise while preserving the fringe edges. First, the proposed adaptive filter step, performed before frequency estimation, is employed to improve the estimation accuracy. Subsequently, to preserve the fringe characteristics, the estimated fringe frequency in each fixed filtering patch is removed from the original noisy phase. Then, the residual phase is smoothed based on the modified Goldstein filter with its parameter alpha dependent on both the coherence map and the residual phase frequency. Finally, the filtered residual phase and the removed fringe frequency are combined to generate the filtered interferogram, with the loss of signal minimized while reducing the noise level. The effectiveness of the proposed method is verified by experimental results based on both simulated and real data. PMID:27886081

  1. Deep learning approaches for detection and removal of ghosting artifacts in MR spectroscopy.

    PubMed

    Kyathanahally, Sreenath P; Döring, André; Kreis, Roland

    2018-09-01

    To make use of deep learning (DL) methods to detect and remove ghosting artifacts in clinical magnetic resonance spectra of human brain. Deep learning algorithms, including fully connected neural networks, deep-convolutional neural networks, and stacked what-where auto encoders, were implemented to detect and correct MR spectra containing spurious echo ghost signals. The DL methods were trained on a huge database of simulated spectra with and without ghosting artifacts that represent complex variations of ghost-ridden spectra, transformed to time-frequency spectrograms. The trained model was tested on simulated and in vivo spectra. The preliminary results for ghost detection are very promising, reaching almost 100% accuracy, and the DL ghost removal methods show potential in simulated and in vivo spectra, but need further refinement and quantitative testing. Ghosting artifacts in spectroscopy are problematic, as they superimpose with metabolites and lead to inaccurate quantification. Detection and removal of ghosting artifacts using traditional machine learning approaches with feature extraction/selection is difficult, as ghosts appear at different frequencies. Here, we show that DL methods perform extremely well for ghost detection if the spectra are treated as images in the form of time-frequency representations. Further optimization for in vivo spectra will hopefully confirm their "ghostbusting" capacity. Magn Reson Med 80:851-863, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  2. The Application of GIM in Precise Orbit Determination for LEO Satellites with Single-frequency GPS Measurements

    NASA Astrophysics Data System (ADS)

    Peng, D. J.; Wu, B.

    2012-01-01

    With the availability of precise GPS ephemeris and clock solution, the ionospheric range delay is left as the dominant error sources in the post-processing of space-borne GPS data from single-frequency receivers. Thus, the removal of ionospheric effects is a major prerequisite for an improved orbit reconstruction of LEO satellites equipped with low cost single-frequency GPS receivers. In this paper, the use of Global Ionospheric Maps (GIM) in kinematic and dynamic orbit determination for LEO satellites with single-frequency GPS measurements is discussed first,and then, estimating the scale factor of ionosphere to remove the ionospheric effects in C/A code pseudo-range measurements in both kinematic and adynamia orbit defemination approaches is addressed. As it is known the ionospheric path delay of space-borne GPS signals is strongly dependent on the orbit altitudes of LEO satellites, we selected real space-borne GPS data from CHAMP, GRACE, TerraSAR-X and SAC-C satellites with altitudes between 300 km and 800 km as sample data in this paper. It is demonstrated that the approach of eliminating ionospheric effects in space-borne C/A code pseudo-range by estimating the scale factor of ionosphere is highly effective. Employing this approach, the accuracy of both kinematic and dynamic orbits can be improved notably. Among those five LEO satellites, CHAMP with the lowest orbit altitude has the most remarkable orbit accuracy improvements, which are 55.6% and 47.6% for kinematic and dynamic approaches, respectively. SAC-C with the highest orbit altitude has the least orbit accuracy improvements accordingly, which are 47.8% and 38.2%, respectively.

  3. The Application of GIM in Precise Orbit Determination for LEO Satellites with Single-Frequency GPS Measurements

    NASA Astrophysics Data System (ADS)

    Peng, Dong-ju; Wu, Bin

    2012-10-01

    With the precise GPS ephemeris and clock error available, the iono- spheric delay is left as the dominant error source in the single-frequency GPS data. Thus, the removal of ionospheric effects is a ma jor prerequisite for an improved orbit reconstruction of LEO satellites based on the single-frequency GPS data. In this paper, the use of Global Ionospheric Maps (GIM) in kine- matic and dynamic orbit determinations for LEO satellites with single-frequency GPS pseudorange measurements is discussed first, and then, estimating the iono- spheric scale factor to remove the ionospheric effects from the C/A-code pseu- dorange measurements for both kinematic and dynamic orbit determinations is addressed. As it is known that the ionospheric delay of space-borne GPS sig- nals is strongly dependent on the orbit altitudes of LEO satellites, we select the real C/A-code pseudorange measurement data of the CHAMP, GRACE, TerraSAR-X and SAC-C satellites with altitudes between 300 km and 800 km as sample data in this paper. It is demonstrated that the approach to eliminating ionospheric effects in C/A-code pseudorange measurements by estimating the ionospheric scale factor is highly effective. Employing this approach, the accu- racy of both kinematic and dynamic orbits can be improved notably. Among those five LEO satellites, CHAMP with the lowest orbit altitude has the most remarkable improvements in orbit accuracy, which are 55.6% and 47.6% for kine- matic and dynamic orbits, respectively. SAC-C with the highest orbit altitude has the least improvements in orbit accuracy accordingly, which are 47.8% and 38.2%, respectively.

  4. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector.

    PubMed

    Musumeci, P; Moody, J T; Scoby, C M; Gutierrez, M S; Bender, H A; Wilcox, N S

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  5. Selective ablation of sub- and supragingival calculus with a frequency-doubled Alexandrite laser

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas

    1995-05-01

    In a preceding trial the absorption characteristics of subgingival calculus were calculated using fluorescence emission spectroscopy (excitation laser: N2-laser, wavelength 337 nm, pulse duration 4 ns). Subgingival calculus seems to contain chromophores absorbing in the ultraviolet spectral region up to 420 nm. The aim of the actual study was the ablation of sub- and supragingival calculus using a frequency doubled Alexandrite-laser (wavelength 377 nm, pulse duration 100 ns, repetition rate 110 Hz). Extracted human teeth presenting sub- and supragingival calculus were irradiated perpendicular to their axis with a laser fluence of 1 Jcm-2. Using a standard application protocol calculus was irradiated at the enamel surface, at the junction between enamel and root, and at the root surface (located on dentin or on cementum). During the irradiation procedure an effective water cooling-system was engaged. For light microscopical investigations undecalcified histological sections were prepared after treatment. The histological sections revealed that a selective and total removal of calculus is possible at all locations without ablation of healthy enamel, dentin or cementum. Even low fluences provide us with a high effectiveness for the ablation of calculus. Thus, based on different absorption characteristics and ablation thresholds, engaging a frequency doubled Alexandrite-laser a fast and, even more, a selective ablation of sub- and supragingival calculus is possible without adverse side effects to the surrounding tissues. Even more, microbial dental plaque can be perfectly removed.

  6. Surface oxidation of GaN(0001): Nitrogen plasma-assisted cleaning for ultrahigh vacuum applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gangopadhyay, Subhashis; Schmidt, Thomas, E-mail: tschmidt@ifp.uni-bremen.de; Kruse, Carsten

    The cleaning of metal-organic vapor-phase epitaxial GaN(0001) template layers grown on sapphire has been investigated. Different procedures, performed under ultrahigh vacuum conditions, including degassing and exposure to active nitrogen from a radio frequency nitrogen plasma source have been compared. For this purpose, x-ray photoelectron spectroscopy, reflection high-energy electron diffraction, and scanning tunneling microscopy have been employed in order to assess chemical as well as structural and morphological surface properties. Initial degassing at 600 °C under ultrahigh vacuum conditions only partially eliminates the surface contaminants. In contrast to plasma assisted nitrogen cleaning at temperatures as low as 300 °C, active-nitrogen exposure at temperaturesmore » as high as 700 °C removes the majority of oxide species from the surface. However, extended high-temperature active-nitrogen cleaning leads to severe surface roughening. Optimum results regarding both the removal of surface oxides as well as the surface structural and morphological quality have been achieved for a combination of initial low-temperature plasma-assisted cleaning, followed by a rapid nitrogen plasma-assisted cleaning at high temperature.« less

  7. Deterministic ion beam material adding technology for high-precision optical surfaces.

    PubMed

    Liao, Wenlin; Dai, Yifan; Xie, Xuhui; Zhou, Lin

    2013-02-20

    Although ion beam figuring (IBF) provides a highly deterministic method for the precision figuring of optical components, several problems still need to be addressed, such as the limited correcting capability for mid-to-high spatial frequency surface errors and low machining efficiency for pit defects on surfaces. We propose a figuring method named deterministic ion beam material adding (IBA) technology to solve those problems in IBF. The current deterministic optical figuring mechanism, which is dedicated to removing local protuberances on optical surfaces, is enriched and developed by the IBA technology. Compared with IBF, this method can realize the uniform convergence of surface errors, where the particle transferring effect generated in the IBA process can effectively correct the mid-to-high spatial frequency errors. In addition, IBA can rapidly correct the pit defects on the surface and greatly improve the machining efficiency of the figuring process. The verification experiments are accomplished on our experimental installation to validate the feasibility of the IBA method. First, a fused silica sample with a rectangular pit defect is figured by using IBA. Through two iterations within only 47.5 min, this highly steep pit is effectively corrected, and the surface error is improved from the original 24.69 nm root mean square (RMS) to the final 3.68 nm RMS. Then another experiment is carried out to demonstrate the correcting capability of IBA for mid-to-high spatial frequency surface errors, and the final results indicate that the surface accuracy and surface quality can be simultaneously improved.

  8. 47 CFR 78.103 - Emissions and emission limitations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Amplitude Modulation: For vestigial sideband AM video: On any frequency removed from the center frequency of...) Maximum authorized band-width (MHz) 1,990 to 2,110 17 or 18.1 6,425 to 6,525 8 or 25. 6,875 to 7,125 25...

  9. 47 CFR 78.103 - Emissions and emission limitations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Amplitude Modulation: For vestigial sideband AM video: On any frequency removed from the center frequency of...) Maximum authorized band-width (MHz) 1,990 to 2,110 17 or 18.1 6,425 to 6,525 8 or 25. 6,875 to 7,125 25...

  10. 47 CFR 78.103 - Emissions and emission limitations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Amplitude Modulation: For vestigial sideband AM video: On any frequency removed from the center frequency of...) Maximum authorized band-width (MHz) 1,990 to 2,110 17 or 18.1 6,425 to 6,525 8 or 25. 6,875 to 7,125 25...

  11. 47 CFR 78.103 - Emissions and emission limitations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Amplitude Modulation: For vestigial sideband AM video: On any frequency removed from the center frequency of...) Maximum authorized band-width (MHz) 1,990 to 2,110 17 or 18.1 6,425 to 6,525 8 or 25. 6,875 to 7,125 25...

  12. 47 CFR 78.103 - Emissions and emission limitations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Amplitude Modulation: For vestigial sideband AM video: On any frequency removed from the center frequency of...) Maximum authorized band-width (MHz) 1,990 to 2,110 17 or 18.1 6,425 to 6,525 8 or 25. 6,875 to 7,125 25...

  13. Carbon Nanotube Purification

    NASA Technical Reports Server (NTRS)

    Delzeit, Lance D. (Inventor); Delzeit, Clement J. (Inventor)

    2005-01-01

    A method for cleaning or otherwise removing amorphous carbon and other residues that arise in growth of a carbon nanotube (CNT) array. The CNT array is exposed to a plurality of hydroxyls or hydrogen, produced from a selected vapor or liquid source such as H2O or H2O2. and the hydroxyls or hydrogen (neutral or electrically charged) react with the residues to produce partly or fully dissolved or hydrogenated or hydroxylizated products that can be removed or separated from the CNT array. The hydroxyls or hydrogen can be produced by heating the CNT array, residue and selected vapor or liquid source or by application of an electromagnetic excitation signal with a selected frequency or range of frequencies to dissociate the selected vapor or liquid. The excitation frequency can be chirped to cover a selected range of frequencies corresponding to dissociation of the selected vapor or liquid. Sonication may be uscd to supplement dissociation of the H2O and/or H2O2.

  14. Frequency of CD4+CD25+Foxp3+ cells in peripheral blood in relation to urinary bladder cancer malignancy indicators before and after surgical removal.

    PubMed

    Jóźwicki, Wojciech; Brożyna, Anna A; Siekiera, Jerzy; Slominski, Andrzej T

    2016-03-08

    Tumor cells communicate with stromal cells, including cancer-associated fibroblasts (CAFs) and tumor-associated macrophages (TAMs), to form microenvironment inhibiting immune responses. Regulatory T cells (Tregs, CD4+CD25+FoxP3+) stimulate immune tolerance and facilitate tumor progression. We analyzed the changes in Treg frequencies assessed using flow cytometry in the peripheral blood of patients with urothelial bladder cancer before and after tumor-removal. Changes in Treg frequency were investigated in relation to clinicopathomorphological indicators of tumor malignancy and expression of RCAS1 on CAFs and TAMs. Higher Treg frequencies were observed in early phase of tumor growth (pTa-pT2), in larger tumors, with more aggressive type of invasion, and with expression of RCAS1. The later phase of tumor development, accompanied by a nonclassic differentiations and pT3-pT4 advancement, had lower number of tumor infiltrating lymphocytes (TILs) and lower Treg frequency. Furthermore, in pT2-pT4 tumors, a decreased post-surgery Treg frequency was associated with poorer prognosis: patients with the lowest frequency of Tregs died first. These findings strongly suggest that the Treg frequencies at later phase of tumor growth, associated with a low anti-tumor response, represent a new and important prognostic indicator in urinary bladder cancer.

  15. Feasibility study on a short-pulsed IR wavelength for effective calculus fragmentation

    NASA Astrophysics Data System (ADS)

    Kang, Hyun Wook

    2015-05-01

    Laser-induced lithotripsy has been used for a minimally-invasive surgery to treat kidney-stone disease associated with urinary obstruction. A short-pulsed Tm:YAG laser (λ = 2.01 µm) was developed to improve fragmentation efficiency and was evaluated with a Ho:YAG laser (λ = 2.12 μm) as to its ablation feature and mass removal rate. Application of a train of sub-microsecond pulses with a lower energy at a frequency of 500 Hz created multiple events of cavitation that accompanied strong acoustic transients. During Tm:YAG irradiation, both high light absorption and secondary photomechanical impacts readily fragmented the calculus into small pieces (< 3 mm) and removed them 130 times faster than photothermal Ho:YAG lithotripsy. The proposed short-pulsed Tm:YAG approach may be an effective lithotripter for treating calculus disease.

  16. Does smoking habit increase the micronuclei frequency in the oral mucosa of adults compared to non-smokers? A systematic review and meta-analysis.

    PubMed

    de Geus, Juliana Larocca; Wambier, Letícia Maíra; Bortoluzzi, Marcelo Carlos; Loguercio, Alessandro D; Kossatz, Stella; Reis, Alessandra

    2018-01-01

    A systematic review of clinical studies to evaluate the frequency of micronuclei in the oral mucosa of smokers and non-smokers in adult patients was performed. A comprehensive search was carried out on MEDLINE via PubMeb, Scopus, Web of Science, LILACS, BBO, and Cochrane Library and SIGLE without restrictions. Dissertations and thesis were searched using the ProQuest Dissertations and Periodicos Capes Thesis Databases. We included only cross-sectional clinical trials that compared the frequency of micronuclei in the oral mucosa of smokers and non-smokers in adult patients. After the removal of duplicates, 1338 articles were identified. After title and abstract screening, 35 studies remained. Eighteen studies were further excluded, whereas 17 studies remained for qualitative analysis and 16 for the meta-analysis of the primary and secondary outcomes. A significant difference in the frequency of micronuclei in smokers when compared to non-smokers was observed in the present study. Despite the high variation in the methodology of the assessed studies, this study showed a higher frequency of micronuclei in exfoliated cells of smokers compared to non-smokers. The use of tobacco is associated with cytotoxic and genotoxic effects because a higher frequency of micronuclei in exfoliated cells of smokers was observed.

  17. Statistical analysis of low level atmospheric turbulence

    NASA Technical Reports Server (NTRS)

    Tieleman, H. W.; Chen, W. W. L.

    1974-01-01

    The statistical properties of low-level wind-turbulence data were obtained with the model 1080 total vector anemometer and the model 1296 dual split-film anemometer, both manufactured by Thermo Systems Incorporated. The data obtained from the above fast-response probes were compared with the results obtained from a pair of Gill propeller anemometers. The digitized time series representing the three velocity components and the temperature were each divided into a number of blocks, the length of which depended on the lowest frequency of interest and also on the storage capacity of the available computer. A moving-average and differencing high-pass filter was used to remove the trend and the low frequency components in the time series. The calculated results for each of the anemometers used are represented in graphical or tabulated form.

  18. Theory of many-body localization in periodically driven systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abanin, Dmitry A., E-mail: dabanin@gmail.com; De Roeck, Wojciech; Huveneers, François

    We present a theory of periodically driven, many-body localized (MBL) systems. We argue that MBL persists under periodic driving at high enough driving frequency: The Floquet operator (evolution operator over one driving period) can be represented as an exponential of an effective time-independent Hamiltonian, which is a sum of quasi-local terms and is itself fully MBL. We derive this result by constructing a sequence of canonical transformations to remove the time-dependence from the original Hamiltonian. When the driving evolves smoothly in time, the theory can be sharpened by estimating the probability of adiabatic Landau–Zener transitions at many-body level crossings. Inmore » all cases, we argue that there is delocalization at sufficiently low frequency. We propose a phase diagram of driven MBL systems.« less

  19. Test of the Equivalence Principle in an Einstein Elevator

    NASA Technical Reports Server (NTRS)

    Shapiro, Irwin I.; Lorenzini, E. C.; Glashow, S.; Cosmo, M. L.; Cheimets, P.; Finkelstein, N.; Schneps, M.; Iafolla, V.; Nozzoli, S.

    2003-01-01

    The laboratory activity consisted in the construction of a laboratory prototype of a differential accelerometer. The laboratory prototype has been used to conduct key tests on the differential instrument. We demonstrated the ability to damp quickly transient oscillations by utilizing a resistive load in the feedback loops and then removing that load to reestablish a high quality factor of the detector. A rotating divide with tilt control was also built. This device was utilized to impart (through the Earth's gravity) common-mode perturbations to the differential accelerometer. These calibration disturbances have been used to trim the acceleration outputs of the individual proof masses in order to obtain a common-mode rejection factor better than 10(exp -4) in a sufficiently large frequency band centered at the spin frequency.

  20. Simulation Study Using a New Type of Sample Variance

    NASA Technical Reports Server (NTRS)

    Howe, D. A.; Lainson, K. J.

    1996-01-01

    We evaluate with simulated data a new type of sample variance for the characterization of frequency stability. The new statistic (referred to as TOTALVAR and its square root TOTALDEV) is a better predictor of long-term frequency variations than the present sample Allan deviation. The statistical model uses the assumption that a time series of phase or frequency differences is wrapped (periodic) with overall frequency difference removed. We find that the variability at long averaging times is reduced considerably for the five models of power-law noise commonly encountered with frequency standards and oscillators.

  1. Laser removal of sludge from steam generators

    DOEpatents

    Nachbar, Henry D.

    1990-01-01

    A method of removing unwanted chemical deposits known as sludge from the metal surfaces of steam generators with laser energy is provided. Laser energy of a certain power density, of a critical wavelength and frequency, is intermittently focused on the sludge deposits to vaporize them so that the surfaces are cleaned without affecting the metal surface (sludge substrate). Fiberoptic tubes are utilized for laser beam transmission and beam direction. Fiberoptics are also utilized to monitor laser operation and sludge removal.

  2. Planck 2013 results. X. HFI energetic particle effects: characterization, removal, and simulation

    NASA Astrophysics Data System (ADS)

    Planck Collaboration; Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J. J.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Bridges, M.; Bucher, M.; Burigana, C.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chiang, H. C.; Chiang, L.-Y.; Christensen, P. R.; Church, S.; Clements, D. L.; Colombi, S.; Colombo, L. P. L.; Couchot, F.; Coulais, A.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Dupac, X.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Finelli, F.; Forni, O.; Frailis, M.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Girard, D.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K. M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Hansen, F. K.; Hanson, D.; Harrison, D.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Hornstrup, A.; Hovest, W.; Huffenberger, K. M.; Jaffe, A. H.; Jaffe, T. R.; Jones, W. C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T. S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Laureijs, R. J.; Lawrence, C. R.; Leonardi, R.; Leroy, C.; Lesgourgues, J.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P. M.; Macías-Pérez, J. F.; Mandolesi, N.; Maris, M.; Marshall, D. J.; Martin, P. G.; Martínez-González, E.; Masi, S.; Massardi, M.; Matarrese, S.; Matthai, F.; Mazzotta, P.; McGehee, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Miniussi, A.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Mottet, S.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; Noviello, F.; Novikov, D.; Novikov, I.; Osborne, S.; Oxborrow, C. A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G. W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Racine, B.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rusholme, B.; Sanselme, L.; Santos, D.; Sauvé, A.; Savini, G.; Scott, D.; Shellard, E. P. S.; Spencer, L. D.; Starck, J.-L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sureau, F.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Tavagnacco, D.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L. A.; Wandelt, B. D.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-11-01

    We describe the detection, interpretation, and removal of the signal resulting from interactions of high energy particles with the Planck High Frequency Instrument (HFI). There are two types of interactions: heating of the 0.1 K bolometer plate; and glitches in each detector time stream. The transientresponses to detector glitch shapes are not simple single-pole exponential decays and fall into three families. The glitch shape for each family has been characterized empirically in flight data and these shapes have been used to remove glitches from the detector time streams. The spectrum of the count rate per unit energy is computed for each family and a correspondence is made to the location on the detector of the particle hit. Most of the detected glitches are from Galactic protons incident on the die frame supporting the micro-machined bolometric detectors. In the Planck orbit at L2, the particle flux is around 5 cm-2 s-1 and is dominated by protons incident on the spacecraft with energy >39 MeV, at a rate of typically one event per second per detector. Different categories of glitches have different signatures in the time stream. Two of the glitch types have a low amplitude component that decays over nearly 1 s. This component produces excess noise if not properly removed from the time-ordered data. We have used a glitch detection and subtraction method based on the joint fit of population templates. The application of this novel glitch subtraction method removes excess noise from the time streams. Using realistic simulations, we find that this method does not introduce signal bias into the Planck data.

  3. Nitrate removal from pharmaceutical wastewater using microbial electrochemical system supplied through low frequency-low voltage alternating electric current.

    PubMed

    Hoseinzadeh, Edris; Rezaee, Abbas; Farzadkia, Mahdi

    2018-04-01

    In this study, a microbial electrochemical system (MES) was designed to evaluate the effects of a low frequency-low voltage alternating electrical current on denitrification efficacy in the presence of ibuprofen as a low biodegradable organic carbon source. Cylindrical carbon cloth and stainless steel mesh electrodes containing a consortium of heterotrophic and autotrophic bacteria were mounted in the wall of the designed laboratory-scale bioreactor. The effects of inlet nitrate concentration (50-800mgL -1 ), retention time (2.5-24h), waveform magnitude (0.1-9.6V p-p ), adjustable direct current voltage added to offset voltage (0.1-4.9V), alternating current frequency (10-60Hz), and waveforms (sinusoidal, square, and ramp) were studied in this work. The results showed that the proposed system removes 800mgL -1 nitrate up to 95% during 6.5h. Optimum conditions were obtained in the 8V p-p using a frequency of 10Hz of a sinusoidal waveform. The morphology studies confirmed bacterial morphology change when applying the alternating current. Dehydrogenase activity of biofilms formed on surface of stainless steel electrodes increased to 15.24μgTFmg biomass cm -2 d. The maximum bacterial activity was obtained at a voltage of 8V p-p . The experimental results revealed that the MES using a low frequency-low voltage alternating electrical current is a promising technique for nitrate removal from pharmaceutical wastewaters in the presence of low biodegradability of carbon sources such as ibuprofen. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. A Novel Method of High Accuracy, Wavefront Phase and Amplitude Correction for Coronagraphy

    NASA Technical Reports Server (NTRS)

    Bowers, Charles W.; Woodgate, Bruce E.; Lyon, Richard G.

    2003-01-01

    Detection of extra-solar, and especially terrestrial-like planets, using coronagraphy requires an extremely high level of wavefront correction. For example, the study of Woodruff et al. (2002) has shown that phase uniformity of order 10(exp -4)lambda(rms) must be achieved over the critical range of spatial frequencies to produce the approx. 10(exp 10) contrast needed for the Terrestrial Planet Finder (TPF) mission. Correction of wavefront phase errors to this level may be accomplished by using a very high precision deformable mirror (DM). However, not only phase but also amplitude uniformity of the same scale (approx. 10(exp -4)) and over the same spatial frequency range must be simultaneously obtained to remove all residual speckle in the image plane. We present a design for producing simultaneous wavefront phase and amplitude uniformity to high levels from an input wavefront of lower quality. The design uses a dual Michelson interferometer arrangement incorporating two DM and a single, fixed mirror (all at pupils) and two beamsplitters: one with unequal (asymmetric) beam splitting and one with symmetric beam splitting. This design allows high precision correction of both phase and amplitude using DM with relatively coarse steps and permits a simple correction algorithm.

  5. Performance of system consisting of vertical flow trickling filter and horizontal flow multi-soil-layering reactor for treatment of rural wastewater.

    PubMed

    Zhang, Yi; Cheng, Yan; Yang, Chunping; Luo, Wei; Zeng, Guangming; Lu, Li

    2015-10-01

    In order to improve nitrogen removal for rural wastewater, a novel two-stage hybrid system, consisting of a vertical flow trickling filter (VFTF) and a horizontal flow multi-soil-layering (HFMSL) bioreactor was developed. The performance of the apparatus was observed under various carbon-nitrogen ratios and water spraying frequencies separately. The maximum removal efficiency of total nitrogen (TN) for the hybrid system was 92.8% while the removal rates of CODCr, ammonium (NH4(+)-N), and total phosphorus (TP) were 94.1%, 96.1%, 92.0% respectively, and the corresponding effluent concentrations were 3.61, 21.20, 1.91, and 0.33 mg L(-1). The horizontal flow mode for MSL led the system to denitrifying satisfactorily as it ensured relatively long hydraulic retention time (HRT), ideal anoxic condition and adequate organic substrates supply. Also, higher water spraying frequency benefited intermittent feeding system for pollutants removal. Shock loading test indicated that the hybrid system could operate well even at hydraulic shock loadings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Frequency of second mesiobuccal canal in permanent maxillary first molars using the operating microscope and selective dentin removal: A clinical study.

    PubMed

    Das, Suroopa; Warhadpande, Manjusha M; Redij, Saurabh A; Jibhkate, N G; Sabir, Husain

    2015-01-01

    The aim of this study was to investigate whether the combination of operating microscope and selective dentin removal increased the frequency of second mesiobuccal (MB2) canal detection in permanent maxillary first molar teeth. One hundred fifty permanent maxillary first molars indicated for root canal treatment were randomly selected from patients belonging to the age group of 18-45 years irrespective of gender. After access cavity preparation and location of main canals, the MB2 canal orifice was sought in all teeth with an endodontic explorer under direct vision (Stage I), then under magnification with the aid of operating microscope (Stage II) and finally with the combined use of operating microscope and selective dentin removal (Stage III). MB2 canals were detected in 36%, 54% and 72% of the teeth in Stages I-III, respectively. This study demonstrated that dental operating microscope when used along with adjunctive aids such as selective dentin removal/troughing and good clinical knowledge will increase the ability of dental clinician to locate MB2 canals.

  7. Nonlinear analysis of a relativistic beam-plasma cyclotron instability

    NASA Technical Reports Server (NTRS)

    Sprangle, P.; Vlahos, L.

    1986-01-01

    A self-consistent set of nonlinear and relativistic wave-particle equations are derived for a magnetized beam-plasma system interacting with electromagnetic cyclotron waves. In particular, the high-frequency cyclotron mode interacting with a streaming and gyrating electron beam within a background plasma is considered in some detail. This interaction mode may possibly find application as a high-power source of coherent short-wavelength radiation for laboratory devices. The background plasma, although passive, plays a central role in this mechanism by modifying the dielectric properties in which the magnetized electron beam propagates. For a particular choice of the transverse beam velocity (i.e., the speed of light divided by the relativistic mass factor), the interaction frequency equals the nonrelativistic electron cyclotron frequency times the relativistic mass factor. For this choice of transverse beam velocity the detrimental effects of a longitudinal beam velocity spread is virtually removed. Power conversion efficiencies in excess of 18 percent are both analytically calculated and obtained through numerical simulations of the wave-particle equations. The quality of the electron beam, degree of energy and pitch angle spread, and its effect on the beam-plasma cyclotron instability is studied.

  8. Microplasma generator and methods therefor

    DOEpatents

    Hopwood, Jeffrey A

    2015-04-14

    A low-temperature, atmospheric-pressure microplasma generator comprises at least one strip of metal on a dielectric substrate. A first end of the strip is connected to a ground plane and the second end of the strip is adjacent to a grounded electrode, with a gap being defined between the second end of the strip and the grounded electrode. High frequency power is supplied to the strip. The frequency is selected so that the length of the strip is an odd integer multiple of 1/4 of the wavelength traveling on the strip. A microplasma forms in the gap between the second end of the strip and the grounded electrode due to electric fields in that region. A microplasma generator array comprises a plurality of strongly-coupled resonant strips in close proximity to one another. At least one of the strips has an input for high-frequency electrical power. The remaining strips resonate due to coupling from the at least one powered strip. The array can provide a continuous line or ring of plasma. The microplasma generator can be used to alter the surface of a substrate, such as by adding material (deposition), removal of material (etching), or modifying surface chemistry.

  9. Multi-frequency communication system and method

    DOEpatents

    Carrender, Curtis Lee; Gilbert, Ronald W.

    2004-06-01

    A multi-frequency RFID remote communication system is provided that includes a plurality of RFID tags configured to receive a first signal and to return a second signal, the second signal having a first frequency component and a second frequency component, the second frequency component including data unique to each remote RFID tag. The system further includes a reader configured to transmit an interrogation signal and to receive remote signals from the tags. A first signal processor, preferably a mixer, removes an intermediate frequency component from the received signal, and a second processor, preferably a second mixer, analyzes the IF frequency component to output data that is unique to each remote tag.

  10. HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR MULTI-FREQUENCY CALIBRATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodson, Richard; Rioja, María J.; Molina, Sol N.

    In this paper we describe a new approach for millimeter Very Long Baseline Interferometry (mm-VLBI) calibration that provides bona-fide astrometric alignment of the millimeter-wavelength images from a single source, for the measurement of frequency-dependent effects, such as “core-shifts” near the black hole of active galactic nucleus jets. We achieve our astrometric alignment by solving first for the ionospheric (dispersive) contributions using wide-band centimeter-wavelength observations. Second, we solve for the tropospheric (non-dispersive) contributions by using fast frequency-switching at the target millimeter-wavelengths. These solutions can be scaled and transferred from low frequency to the high frequency. To complete the calibration chain anmore » additional step is required to remove a residual constant phase offset on each antenna. The result is an astrometric calibration and the measurement of the core-shift between 22 and 43 GHz for the jet in BL Lacertae to be −8 ± 5, 20 ± 6 μ as, in R.A. and decl., respectively. By comparison to conventional phase referencing at centimeter-wavelengths we are able to show that this core shift at millimeter-wavelengths is significantly less than what would be predicted by extrapolating the low-frequency result, which closely followed the predictions of the Blandford and Königl conical jet model. As such it would be the first demonstration for the association of the VLBI core with a recollimation shock, normally hidden at low frequencies due to the optical depth, which could be responsible for the γ -ray production in blazar jets.« less

  11. Application of Kalman filter in frequency offset estimation for coherent optical quadrature phase-shift keying communication system

    NASA Astrophysics Data System (ADS)

    Jiang, Wen; Yang, Yanfu; Zhang, Qun; Sun, Yunxu; Zhong, Kangping; Zhou, Xian; Yao, Yong

    2016-09-01

    The frequency offset estimation (FOE) schemes based on Kalman filter are proposed and investigated in detail via numerical simulation and experiment. The schemes consist of a modulation phase removing stage and Kalman filter estimation stage. In the second stage, the Kalman filters are employed for tracking either differential angles or differential data between two successive symbols. Several implementations of the proposed FOE scheme are compared by employing different modulation removing methods and two Kalman algorithms. The optimal FOE implementation is suggested for different operating conditions including optical signal-to-noise ratio and the number of the available data symbols.

  12. Stimulated emission and spontaneous loss pump-probe microscopy for background removal

    NASA Astrophysics Data System (ADS)

    Das, Subir; Ho, Bo-Wei; Kao, Fu-Jen

    2018-02-01

    In this work, we have established a double modulation lock-in detection technique using two semiconductor laser diodes in stimulated emission based pump-probe microscopy. By modulating the pump and probe beams at two different frequencies, f1 and f2, the signal is then recovered with the sum frequency, (f1+ f2), so as to minimize the leak-through noise due to the spontaneous emission caused by the pump beam. In this way, the DC background that is often attributed to the stimulated emission is effectively removed. Our technique has implemented in ATTO647N fluorescent dye which is applicable for many biological applications.

  13. An L-band transit-time oscillator with mechanical frequency tunability

    NASA Astrophysics Data System (ADS)

    Song, Lili; He, Juntao; Ling, Junpu; Cao, Yibing

    2017-02-01

    An L-band coaxial Transit-time Oscillator (TTO) with mechanical frequency tunability is introduced in this paper. Particle-in-cell simulations have been done. The output power efficiency has been improved at least 20% under a 10.2 GW input power and with a tunable range from 1.57 GHz to 1.90 GHz by modulating the outer conductor. It is worth to note that the efficiency can reach as high as 41% at 1.75 GHz. The mechanical engineering method is also detailed in this work. The frequency tuning range of the coaxial TTO is 22.6% of the central frequency. On the other hand, the frequency can be tuned from 1.6 GHz to 1.85 GHz by modulating the inner conductor. The author highlights a hollow structure of the L-band coaxial TTO which can work from 1.03 GHz to 1.31 GHz via modulating the outer conductor in the rest of the article. The frequency tuning range of the hollow TTO is 21.4% of the central frequency. More importantly, the hollow TTO can be easily achieved after the inner conductor is removed from the coaxial TTO. The electric field distributions of the coaxial and hollow TTOs are analyzed, resulting in that the longitudinal and transverse working modes are TM01 and π mode, respectively. The same working mode from these two structures implies the stability of the TTOs mentioned above.

  14. An improved ring removal procedure for in-line x-ray phase contrast tomography

    NASA Astrophysics Data System (ADS)

    Massimi, Lorenzo; Brun, Francesco; Fratini, Michela; Bukreeva, Inna; Cedola, Alessia

    2018-02-01

    The suppression of ring artifacts in x-ray computed tomography (CT) is a required step in practical applications; it can be addressed by introducing refined digital low pass filters within the reconstruction process. However, these filters may introduce additional ringing artifacts when simultaneously imaging pure phase objects and elements having a non-negligible absorption coefficient. Ringing originates at sharp interfaces, due to the truncation of spatial high frequencies, and severely affects qualitative and quantitative analysis of the reconstructed slices. In this work, we discuss the causes of ringing artifacts, and present a general compensation procedure to account for it. The proposed procedure has been tested with CT datasets of the mouse central nervous system acquired at different synchrotron radiation facilities. The results demonstrate that the proposed method compensates for ringing artifacts induced by low pass ring removal filters. The effectiveness of the ring suppression filters is not altered; the proposed method can thus be considered as a framework to improve the ring removal step, regardless of the specific filter adopted or the imaged sample.

  15. Start-up of an UASB-septic tank for community on-site treatment of strong domestic sewage.

    PubMed

    Al-Shayah, Mohammad; Mahmoud, Nidal

    2008-11-01

    Two community on-site UASB-septic tanks were operated in parallel over a six months period under two different hydraulic retention times (HRT) of 2 days for R1 and 4 days for R2 at mean sewage temperature of 24 degrees C. The sewage was characterised by a high COD(tot) concentration of 1189 mg/L, with a large fraction of COD(sus), viz. 54%. The achieved removal efficiencies in R1 and R2 for COD(tot), COD(sus), BOD5 and TSS were "56%, 87%, 59% and 81%" and "58%, 90%, 60% and 82%" for both systems, respectively. R2 achieved a marginal but significant (p<0.05) better removal efficiencies of those parameters as compared to R1. The COD(col) and COD(dis) removals in R1 and R2 were respectively 31% and 20%, and 34% and 22%. The sludge accumulation was very low suggesting that the desludging frequency will be of several years. Accordingly, the reactor can be adequately designed at 2 days HRT.

  16. An improved ring removal procedure for in-line x-ray phase contrast tomography.

    PubMed

    Massimi, Lorenzo; Brun, Francesco; Fratini, Michela; Bukreeva, Inna; Cedola, Alessia

    2018-02-12

    The suppression of ring artifacts in x-ray computed tomography (CT) is a required step in practical applications; it can be addressed by introducing refined digital low pass filters within the reconstruction process. However, these filters may introduce additional ringing artifacts when simultaneously imaging pure phase objects and elements having a non-negligible absorption coefficient. Ringing originates at sharp interfaces, due to the truncation of spatial high frequencies, and severely affects qualitative and quantitative analysis of the reconstructed slices. In this work, we discuss the causes of ringing artifacts, and present a general compensation procedure to account for it. The proposed procedure has been tested with CT datasets of the mouse central nervous system acquired at different synchrotron radiation facilities. The results demonstrate that the proposed method compensates for ringing artifacts induced by low pass ring removal filters. The effectiveness of the ring suppression filters is not altered; the proposed method can thus be considered as a framework to improve the ring removal step, regardless of the specific filter adopted or the imaged sample.

  17. Frequency-dependent reliability of spike propagation is function of axonal voltage-gated sodium channels in cerebellar Purkinje cells.

    PubMed

    Yang, Zhilai; Wang, Jin-Hui

    2013-12-01

    The spike propagation on nerve axons, like synaptic transmission, is essential to ensure neuronal communication. The secure propagation of sequential spikes toward axonal terminals has been challenged in the neurons with a high firing rate, such as cerebellar Purkinje cells. The shortfall of spike propagation makes some digital spikes disappearing at axonal terminals, such that the elucidation of the mechanisms underlying spike propagation reliability is crucial to find the strategy of preventing loss of neuronal codes. As the spike propagation failure is influenced by the membrane potentials, this process is likely caused by altering the functional status of voltage-gated sodium channels (VGSC). We examined this hypothesis in Purkinje cells by using pair-recordings at their somata and axonal blebs in cerebellar slices. The reliability of spike propagation was deteriorated by elevating spike frequency. The frequency-dependent reliability of spike propagation was attenuated by inactivating VGSCs and improved by removing their inactivation. Thus, the functional status of axonal VGSCs influences the reliability of spike propagation.

  18. A New Strategy for ECG Baseline Wander Elimination Using Empirical Mode Decomposition

    NASA Astrophysics Data System (ADS)

    Shahbakhti, Mohammad; Bagheri, Hamed; Shekarchi, Babak; Mohammadi, Somayeh; Naji, Mohsen

    2016-06-01

    Electrocardiogram (ECG) signals might be affected by various artifacts and noises that have biological and external sources. Baseline wander (BW) is a low-frequency artifact that may be caused by breathing, body movements and loose sensor contact. In this paper, a novel method based on empirical mode decomposition (EMD) for removal of baseline noise from ECG is presented. When compared to other EMD-based methods, the novelty of this research is to reach the optimized number of decomposed levels for ECG BW de-noising using mean power frequency (MPF), while the reduction of processing time is considered. To evaluate the performance of the proposed method, a fifth-order Butterworth high pass filtering (BHPF) with cut-off frequency at 0.5Hz and wavelet approach are applied. Three performance indices, signal-to-noise ratio (SNR), mean square error (MSE) and correlation coefficient (CC), between pure and filtered signals have been utilized for qualification of presented techniques. Results suggest that the EMD-based method outperforms the other filtering method.

  19. Spanish adaptation of social withdrawal motivation and frequency scales.

    PubMed

    Indias García, Sílvia; De Paúl Ochotorena, Joaquín

    2016-11-01

    To adapt into Spanish three scales measuring frequency (SWFS) and motivation for social withdrawal (CSPS and SWMS) and to develop a scale capable of assessing the five motivations for social withdrawal. Participants were 1,112 Spanish adolescents, aged 12-17 years. The sample was randomly split into two groups in which exploratory and confirmatory (CFA) factor analyses were performed separately. A sample of adolescents in residential care (n = 128) was also used to perform discriminant validity analyses. SWFS was reduced to eight items that account for 40% of explained variance (PVE), and its reliability is high. SWMS worked adequately in the original version, according to CFA. Some items from the CSPS were removed from the final Spanish version. The newly developed scale (SWMS-5D) is composed of 20 items including five subscales: Peer Isolation, Unsociability, Shyness, Low Mood and Avoidance. Analyses reveal adequate convergent and discriminant validities. The resulting SWFS-8 and SWMS-5D could be considered useful instruments to assess frequency and motivation for social withdrawal in Spanish samples.

  20. Digital holographic image fusion for a larger size object using compressive sensing

    NASA Astrophysics Data System (ADS)

    Tian, Qiuhong; Yan, Liping; Chen, Benyong; Yao, Jiabao; Zhang, Shihua

    2017-05-01

    Digital holographic imaging fusion for a larger size object using compressive sensing is proposed. In this method, the high frequency component of the digital hologram under discrete wavelet transform is represented sparsely by using compressive sensing so that the data redundancy of digital holographic recording can be resolved validly, the low frequency component is retained totally to ensure the image quality, and multiple reconstructed images with different clear parts corresponding to a laser spot size are fused to realize the high quality reconstructed image of a larger size object. In addition, a filter combing high-pass and low-pass filters is designed to remove the zero-order term from a digital hologram effectively. The digital holographic experimental setup based on off-axis Fresnel digital holography was constructed. The feasible and comparative experiments were carried out. The fused image was evaluated by using the Tamura texture features. The experimental results demonstrated that the proposed method can improve the processing efficiency and visual characteristics of the fused image and enlarge the size of the measured object effectively.

  1. Microcavity morphology optimization

    NASA Astrophysics Data System (ADS)

    Ferdous, Fahmida; Demchenko, Alena A.; Vyatchanin, Sergey P.; Matsko, Andrey B.; Maleki, Lute

    2014-09-01

    High spectral mode density of conventional optical cavities is detrimental to the generation of broad optical frequency combs and to other linear and nonlinear applications. In this work we optimize the morphology of high-Q whispering gallery (WG) and Fabry-Perot (FP) cavities and find a set of parameters that allows treating them, essentially, as single-mode structures, thus removing limitations associated with a high density of cavity mode spectra. We show that both single-mode WGs and single-mode FP cavities have similar physical properties, in spite of their different loss mechanisms. The morphology optimization does not lead to a reduction of quality factors of modes belonging to the basic family. We study the parameter space numerically and find the region where the highest possible Q factor of the cavity modes can be realized while just having a single bound state in the cavity. The value of the Q factor is comparable with that achieved in conventional cavities. The proposed cavity structures will be beneficial for generation of octave spanning coherent frequency combs and will prevent undesirable effects of parametric instability in laser gravitational wave detectors.

  2. Low Frequency Activity of Cortical Networks on Microelectrode Arrays is Differentially Altered by Bicuculline and Carbaryl

    EPA Science Inventory

    Thousands of chemicals need to be characterized for their neurotoxicity potential. Neurons grown on microelectrode arrays (MEAs) are an in vitro model used to screen chemicals for functional effects on neuronal networks. Typically, after removal of low frequency components, effec...

  3. 47 CFR 90.187 - Trunking in the bands between 150 and 512 MHz.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 90.187 Section 90.187 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Policies Governing the Assignment of Frequencies... frequencies (base and mobile) that are 15 kHz or less removed from proposed stations that will operate with a...

  4. A plasmid-based lacZα gene assay for DNA polymerase fidelity measurement

    PubMed Central

    Keith, Brian J.; Jozwiakowski, Stanislaw K.; Connolly, Bernard A.

    2013-01-01

    A significantly improved DNA polymerase fidelity assay, based on a gapped plasmid containing the lacZα reporter gene in a single-stranded region, is described. Nicking at two sites flanking lacZα, and removing the excised strand by thermocycling in the presence of complementary competitor DNA, is used to generate the gap. Simple methods are presented for preparing the single-stranded competitor. The gapped plasmid can be purified, in high amounts and in a very pure state, using benzoylated–naphthoylated DEAE–cellulose, resulting in a low background mutation frequency (∼1 × 10−4). Two key parameters, the number of detectable sites and the expression frequency, necessary for measuring polymerase error rates have been determined. DNA polymerase fidelity is measured by gap filling in vitro, followed by transformation into Escherichia coli and scoring of blue/white colonies and converting the ratio to error rate. Several DNA polymerases have been used to fully validate this straightforward and highly sensitive system. PMID:23098700

  5. Correction for reflected sky radiance in low-altitude coastal hyperspectral images.

    PubMed

    Kim, Minsu; Park, Joong Yong; Kopilevich, Yuri; Tuell, Grady; Philpot, William

    2013-11-10

    Low-altitude coastal hyperspectral imagery is sensitive to reflections of sky radiance at the water surface. Even in the absence of sun glint, and for a calm water surface, the wide range of viewing angles may result in pronounced, low-frequency variations of the reflected sky radiance across the scan line depending on the solar position. The variation in reflected sky radiance can be obscured by strong high-spatial-frequency sun glint and at high altitude by path radiance. However, at low altitudes, the low-spatial-frequency sky radiance effect is frequently significant and is not removed effectively by the typical corrections for sun glint. The reflected sky radiance from the water surface observed by a low-altitude sensor can be modeled in the first approximation as the sum of multiple-scattered Rayleigh path radiance and the single-scattered direct-solar-beam radiance by the aerosol in the lower atmosphere. The path radiance from zenith to the half field of view (FOV) of a typical airborne spectroradiometer has relatively minimal variation and its reflected radiance to detector array results in a flat base. Therefore the along-track variation is mostly contributed by the forward single-scattered solar-beam radiance. The scattered solar-beam radiances arrive at the water surface with different incident angles. Thus the reflected radiance received at the detector array corresponds to a certain scattering angle, and its variation is most effectively parameterized using the downward scattering angle (DSA) of the solar beam. Computation of the DSA must account for the roll, pitch, and heading of the platform and the viewing geometry of the sensor along with the solar ephemeris. Once the DSA image is calculated, the near-infrared (NIR) radiance from selected water scan lines are compared, and a relationship between DSA and NIR radiance is derived. We then apply the relationship to the entire DSA image to create an NIR reference image. Using the NIR reference image and an atmospheric spectral reflectance look-up table, the low spatial frequency variation of the water surface-reflected atmospheric contribution is removed.

  6. Loss of protohaem IX farnesyltransferase in mature dentate granule cells impairs short-term facilitation at mossy fibre to CA3 pyramidal cell synapses.

    PubMed

    Booker, Sam A; Campbell, Graham R; Mysiak, Karolina S; Brophy, Peter J; Kind, Peter C; Mahad, Don J; Wyllie, David J A

    2017-03-15

    Neurodegenerative disorders can exhibit dysfunctional mitochondrial respiratory chain complex IV activity. Conditional deletion of cytochrome c oxidase, the terminal enzyme in the respiratory electron transport chain of mitochondria, from hippocampal dentate granule cells in mice does not affect low-frequency dentate to CA3 glutamatergic synaptic transmission. High-frequency dentate to CA3 glutamatergic synaptic transmission and feedforward inhibition are significantly attenuated in cytochrome c oxidase-deficient mice. Intact presynaptic mitochondrial function is critical for the short-term dynamics of mossy fibre to CA3 synaptic function. Neurodegenerative disorders are characterized by peripheral and central symptoms including cognitive impairments which have been associated with reduced mitochondrial function, in particular mitochondrial respiratory chain complex IV or cytochrome c oxidase activity. In the present study we conditionally removed a key component of complex IV, protohaem IX farnesyltransferase encoded by the COX10 gene, in granule cells of the adult dentate gyrus. Utilizing whole-cell patch-clamp recordings from morphologically identified CA3 pyramidal cells from control and complex IV-deficient mice, we found that reduced mitochondrial function did not result in overt deficits in basal glutamatergic synaptic transmission at the mossy-fibre synapse because the amplitude, input-output relationship and 50 ms paired-pulse facilitation were unchanged following COX10 removal from dentate granule cells. However, trains of stimuli given at high frequency (> 20 Hz) resulted in dramatic reductions in short-term facilitation and, at the highest frequencies (> 50 Hz), also reduced paired-pulse facilitation, suggesting a requirement for adequate mitochondrial function to maintain glutamate release during physiologically relevant activity patterns. Interestingly, local inhibition was reduced, suggesting the effect observed was not restricted to synapses with CA3 pyramidal cells via large mossy-fibre boutons, but rather to all synapses formed by dentate granule cells. Therefore, presynaptic mitochondrial function is critical for the short-term dynamics of synapse function, which may contribute to the cognitive deficits observed in pathological mitochondrial dysfunction. © 2017 The Authors. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.

  7. Can We Infer Ocean Dynamics from Altimeter Wavenumber Spectra?

    NASA Technical Reports Server (NTRS)

    Richman, James; Shriver, Jay; Arbic, Brian

    2012-01-01

    The wavenumber spectra of sea surface height (SSH) and kinetic energy (KE) have been used to infer the dynamics of the ocean. When quasi-geostrophic dynamics (QG) or surface quasi-geostrophic (SQG) turbulence dominate and an inertial subrange exists, a steep SSH wavenumber spectrum is expected with k-5 for QG turbulence and a flatter k-11/3 for SQG turbulence. However, inspection of the spectral slopes in the mesoscale band of 70 to 250 km shows that the altimeter wavenumber slopes typically are much flatter than the QG or SQG predictions over most of the ocean. Comparison of the altimeter wavenumber spectra with the spectra estimated from the output of an eddy resolving global ocean circulation model (the Hybrid Coordinate Ocean Model, HYCOM, at 1/25 resolution), which is forced by high frequency winds and includes the astronomical forcing of the sun and the moon, suggests that the flatter slopes of the altimeter may arise from three possible sources, the presence of internal waves, the lack of an inertial subrange in the 70 to 250 km band and noise or submesoscales at small scales. When the wavenumber spectra of SSH and KE are estimated near the internal tide generating regions, the resulting spectra are much flatter than the expectations of QG or SQG theory. If the height and velocity variability are separated into low frequency (periods greater than 2 days) and high frequency (periods less than a day), then a different pattern emerges with a relatively flat wavenumber spectrum at high frequency and a steeper wavenumber spectrum at low frequency. The stationary internal tides can be removed from the altimeter spectrum, which steepens the spectral slopes in the energetic internal wave regions. Away from generating regions where the internal waves

  8. CORRECTING FOR INTERSTELLAR SCATTERING DELAY IN HIGH-PRECISION PULSAR TIMING: SIMULATION RESULTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palliyaguru, Nipuni; McLaughlin, Maura; Stinebring, Daniel

    2015-12-20

    Light travel time changes due to gravitational waves (GWs) may be detected within the next decade through precision timing of millisecond pulsars. Removal of frequency-dependent interstellar medium (ISM) delays due to dispersion and scattering is a key issue in the detection process. Current timing algorithms routinely correct pulse times of arrival (TOAs) for time-variable delays due to cold plasma dispersion. However, none of the major pulsar timing groups correct for delays due to scattering from multi-path propagation in the ISM. Scattering introduces a frequency-dependent phase change in the signal that results in pulse broadening and arrival time delays. Any methodmore » to correct the TOA for interstellar propagation effects must be based on multi-frequency measurements that can effectively separate dispersion and scattering delay terms from frequency-independent perturbations such as those due to a GW. Cyclic spectroscopy, first described in an astronomical context by Demorest (2011), is a potentially powerful tool to assist in this multi-frequency decomposition. As a step toward a more comprehensive ISM propagation delay correction, we demonstrate through a simulation that we can accurately recover impulse response functions (IRFs), such as those that would be introduced by multi-path scattering, with a realistic signal-to-noise ratio (S/N). We demonstrate that timing precision is improved when scatter-corrected TOAs are used, under the assumptions of a high S/N and highly scattered signal. We also show that the effect of pulse-to-pulse “jitter” is not a serious problem for IRF reconstruction, at least for jitter levels comparable to those observed in several bright pulsars.« less

  9. Modulation of local field potentials by high-frequency stimulation of afferent axons in the hippocampal CA1 region.

    PubMed

    Yu, Ying; Feng, Zhouyan; Cao, Jiayue; Guo, Zheshan; Wang, Zhaoxiang; Hu, Na; Wei, Xuefeng

    2016-03-01

    Modulation of the rhythmic activity of local field potentials (LFP) in neuronal networks could be a mechanism of deep brain stimulation (DBS). However, exact changes of LFP during the periods of high-frequency stimulation (HFS) of DBS are unclear because of the interference of dense stimulation artifacts with high amplitudes. In the present study, we investigated LFP changes induced by HFS of afferent axons in the hippocampal CA1 region of urethane-anesthetized rats by using a proper algorithm of artifact removal. Afterward, the LFP changes in the frequency bands of [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text] and [Formula: see text] rhythms were studied by power spectrum analysis and coherence analysis for the recorded signals collected in the pyramidal layer and in the stratum radiatum of CA1 region before, during and after 1-min long 100 and 200[Formula: see text]Hz HFS. Results showed that the power of LFP rhythms in higher-frequency band ([Formula: see text] rhythm) increased in the pyramidal layer and the power of LFP rhythms in lower-frequency bands ([Formula: see text], [Formula: see text] and [Formula: see text] rhythms) decreased in the stratum radiatum during HFS. The synchronization of [Formula: see text] rhythm decreased and the synchronization of [Formula: see text] rhythm increased during HFS in the stratum radiatum. These results suggest that axonal HFS could modulate LFP rhythms in the downstream brain areas with a plausible underlying mechanism of partial axonal blockage induced by HFS. The study provides new evidence to support the mechanism of DBS modulating rhythmic activity of neuronal populations.

  10. Very High-rate (50 Hz) GPS for Detection of Earthquake Ground Motions : How High Do We Need to Go?

    NASA Astrophysics Data System (ADS)

    Fang, R.

    2017-12-01

    The GPS variometric approach can measure displacements using broadcast ephemeris and a single receiver, with comparable precision to relative positioning and PPP within a short period of time. We evaluate the performance of the variometric approach to measure displacements using very high-rate (50 Hz) GPS data, which recorded from the 2013 Mw 6.6 Lushan earthquake and the 2011 Mw 9.0 Tohoku-Oki earthquake. To remove the nonlinear drift due to integration process, we present to apply a high-pass filter to reconstruct displacements using the variometric approach. Comparison between 50 Hz and 1 Hz coseismic displacements demonstrates that 1 Hz solutions often fail to faithfully manifest the seismic waves containing high-frequency (> 0.5 Hz) seismic signals, which is common for near-field stations during a moderate-magnitude earthquake. Therefore, in order to reconstruct near-field seismic waves caused by moderate or large earthquakes, it is helpful to equip monitoring stations with very high-rate GPS receivers. Results derived using the variometric approach are compared with PPP results. They display very good consistence within only a few millimeters both in static and seismic periods. High-frequency (above 10 Hz) noises of displacements derived using the variometric approach are smaller than PPP displacements in three components.

  11. Seed Dispersal by Ants in the Semi-arid Caatinga of North-east Brazil

    PubMed Central

    Leal, Inara R.; Wirth, Rainer; Tabarelli, Marcelo

    2007-01-01

    Background and Aims Myrmecochory is a conspicuous feature of several sclerophyll ecosystems around the world but it has received little attention in the semi-arid areas of South America. This study addresses the importance of seed dispersal by ants in a 2500-km2 area of the Caatinga ecosystem (north-east Brazil) and investigates ant-derived benefits to the plant through myrmecochory. Methods Seed manipulation and dispersal by ants was investigated during a 3-year period in the Xingó region. Both plant and ant assemblages involved in seed dispersal were described and ant behaviour was characterized. True myrmecochorous seeds of seven Euphorbiaceae species (i.e. elaiosome-bearing seeds) were used in experiments designed to: (1) quantify the rates of seed cleaning/removal and the influence of both seed size and elaiosome presence on seed removal; (2) identify the fate of seeds dispersed by ants; and (3) document the benefits of seed dispersal by ants in terms of seed germination and seedling growth. Key Results Seed dispersal by ants involved one-quarter of the woody flora inhabiting the Xingó region, but true myrmecochory was restricted to 12·8 % of the woody plant species. Myrmecochorous seeds manipulated by ants faced high levels of seed removal (38–84 %) and 83 % of removed seeds were discarded on ant nests. Moreover, seed removal positively correlated with the presence of elaiosome, and elaiosome removal increased germination success by at least 30 %. Finally, some Euphorbiaceae species presented both increased germination and seedling growth on ant-nest soils. Conclusions Myrmecochory is a relevant seed dispersal mode in the Caatinga ecosystem, and is particularly frequent among Euphorbiaceae trees and shrubs. The fact that seeds reach micro-sites suitable for establishment (ant nests) supports the directed dispersal hypothesis as a possible force favouring myrmecochory in this ecosystem. Ecosystems with a high frequency of myrmecochorous plants appear not to be restricted to regions of nutrient-impoverished soil or to fire-prone regions. PMID:17430980

  12. Elementary dispersion analysis of some mimetic discretizations on triangular C-grids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korn, P., E-mail: peter.korn@mpimet.mpg.de; Danilov, S.; A.M. Obukhov Institute of Atmospheric Physics, Moscow

    2017-02-01

    Spurious modes supported by triangular C-grids limit their application for modeling large-scale atmospheric and oceanic flows. Their behavior can be modified within a mimetic approach that generalizes the scalar product underlying the triangular C-grid discretization. The mimetic approach provides a discrete continuity equation which operates on an averaged combination of normal edge velocities instead of normal edge velocities proper. An elementary analysis of the wave dispersion of the new discretization for Poincaré, Rossby and Kelvin waves shows that, although spurious Poincaré modes are preserved, their frequency tends to zero in the limit of small wavenumbers, which removes the divergence noisemore » in this limit. However, the frequencies of spurious and physical modes become close on shorter scales indicating that spurious modes can be excited unless high-frequency short-scale motions are effectively filtered in numerical codes. We argue that filtering by viscous dissipation is more efficient in the mimetic approach than in the standard C-grid discretization. Lumping of mass matrices appearing with the velocity time derivative in the mimetic discretization only slightly reduces the accuracy of the wave dispersion and can be used in practice. Thus, the mimetic approach cures some difficulties of the traditional triangular C-grid discretization but may still need appropriately tuned viscosity to filter small scales and high frequencies in solutions of full primitive equations when these are excited by nonlinear dynamics.« less

  13. Numerical and experimental analysis of high frequency acoustic microscopy and infrared reflectance system for early detection of melanoma

    NASA Astrophysics Data System (ADS)

    Karagiannis, Georgios; Apostolidis, Georgios; Georgoulias, Panagiotis

    2016-03-01

    Melanoma is a very malicious type of cancer as it metastasizes early and hence its late diagnosis leads to death. Consequently, early diagnosis of melanoma and its removal is considered the most effective way of treatment. We present a design of a high frequency acoustic microscopy and infrared reflectance system for the early detection of melanoma. Specifically, the identification of morphological changes related to carcinogenesis is required. In this work, we simulate of the propagation of the ultrasonic waves of the order of 100 MHz as well as of electromagnetic waves of the order of 100 THz in melanoma structures targeting to the estimation and optimization of the basic characteristics of the systems. The simulation results of the acoustic microscopy subsystem aim to provide information such as the geometry of the transducer, the center frequency of operation, the focal length where the power transmittance is optimum and the spot size in focal length. As far as the infrared is concerned the optimal frequency range and the spot illumination size of the external probe is provided. This information is next used to assemble a properly designed system which is applied to melanoma phantoms as well as real skin lesions. Finally, the measurement data are visualized to reveal the information of the experimented structures, proving noteworthy accuracy.

  14. Improving image-quality of interference fringes of out-of-plane vibration using temporal speckle pattern interferometry and standard deviation for piezoelectric plates.

    PubMed

    Chien-Ching Ma; Ching-Yuan Chang

    2013-07-01

    Interferometry provides a high degree of accuracy in the measurement of sub-micrometer deformations; however, the noise associated with experimental measurement undermines the integrity of interference fringes. This study proposes the use of standard deviation in the temporal domain to improve the image quality of patterns obtained from temporal speckle pattern interferometry. The proposed method combines the advantages of both mean and subtractive methods to remove background noise and ambient disturbance simultaneously, resulting in high-resolution images of excellent quality. The out-of-plane vibration of a thin piezoelectric plate is the main focus of this study, providing information useful to the development of energy harvesters. First, ten resonant states were measured using the proposed method, and both mode shape and resonant frequency were investigated. We then rebuilt the phase distribution of the first resonant mode based on the clear interference patterns obtained using the proposed method. This revealed instantaneous deformations in the dynamic characteristics of the resonant state. The proposed method also provides a frequency-sweeping function, facilitating its practical application in the precise measurement of resonant frequency. In addition, the mode shapes and resonant frequencies obtained using the proposed method were recorded and compared with results obtained using finite element method and laser Doppler vibrometery, which demonstrated close agreement.

  15. Msh2 Blocks an Alternative Mechanism for Non-Homologous Tail Removal during Single-Strand Annealing in Saccharomyces cerevisiae

    PubMed Central

    Manthey, Glenn M.; Naik, Nilan; Bailis, Adam M.

    2009-01-01

    Chromosomal translocations are frequently observed in cells exposed to agents that cause DNA double-strand breaks (DSBs), such as ionizing radiation and chemotherapeutic drugs, and are often associated with tumors in mammals. Recently, translocation formation in the budding yeast, Saccharomyces cerevisiae, has been found to occur at high frequencies following the creation of multiple DSBs adjacent to repetitive sequences on non-homologous chromosomes. The genetic control of translocation formation and the chromosome complements of the clones that contain translocations suggest that translocation formation occurs by single-strand annealing (SSA). Among the factors important for translocation formation by SSA is the central mismatch repair (MMR) and homologous recombination (HR) factor, Msh2. Here we describe the effects of several msh2 missense mutations on translocation formation that suggest that Msh2 has separable functions in stabilizing annealed single strands, and removing non-homologous sequences from their ends. Additionally, interactions between the msh2 alleles and a null allele of RAD1, which encodes a subunit of a nuclease critical for the removal of non-homologous tails suggest that Msh2 blocks an alternative mechanism for removing these sequences. These results suggest that Msh2 plays multiple roles in the formation of chromosomal translocations following acute levels of DNA damage. PMID:19834615

  16. Improvements in lung lavage to increase its effectiveness in removing inhaled radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muggenburg, B.A.; Guilmette, R.A.; Romero, L.M.

    Lung lavage has been shown to be an effective method to remove insoluble radionuclides deposited and retained in the lung, but the treatment has been limited to the effective removal of only about 50% of the retained material. Reported here is change in lavage technique that slightly increases the effectiveness and the addition of high-frequency chest wall oscillation. The latter increased the effectiveness of the lavage procedure but also caused significant physiological complications. These studies were conducted in adult male and female beagles. The aerosol in the first study was {sup 239}PuO{sub 2} heat-treated at 850{degrees}C, obtained as powder frommore » a commercial V-blending process. The dogs briefly inhaled the aerosol per nasi. The tissue content at death and the amount of {sup 239}Pu excreted and in the recovered lung lavage fluid was determined by radiochemical methods{sup 5}. These values were used to reconstruct the initial pulmonary burden of {sup 239} and the amount of {sup 239}Pu removed by lavage. In the second study, with the HFCWO, the aerosol was {sup 85}Sr fused in aluminosilicate particles. The IPB of {sup 85}Sr was determined by whole-body counting. The excreta and recovered lung lavage fluids were also assayed for {sup 85}Sr activity.« less

  17. Sono- and photoelectrocatalytic processes for the removal of ionic liquids based on the 1-butyl-3-methylimidazolium cation.

    PubMed

    Mena, Ismael F; Cotillas, Salvador; Díaz, Elena; Sáez, Cristina; Mohedano, Ángel F; Rodrigo, Manuel A

    2017-12-06

    In this work, sono- and photoelectrolysis of synthetic wastewaters polluted with the ionic liquids 1-Butyl-3-methylimidazolium acetate (BmimAc) and chloride (BmimCl) were investigated with diamond anodes. The results were compared to those attained by enhancing bare electrolysis with irradiation by UV light or with the application of high-frequency ultrasound (US). Despite its complex heterocyclic structure, the Bmim + cation was successfully depleted with the three technologies that were tested and was mainly transformed into four different organic intermediates, an inorganic nitrogen species and carbon dioxide. Regardless of the technology that was evaluated, removal of the heterocyclic ring is much less efficient (and much slower) than oxidation of the counter ion. In turn, the counter ion influences the rate of removal of the ionic liquid cation. Thus, the electrolysis and photoelectrolysis of BmimAc are much less efficient than sonoelectrolysis, but their differences become much less important in the case of BmimCl. In this later case, the most efficient technology is photoelectrolysis. This result is directly related to the generation of free radicals in the solution by irradiation of the electrochemical system with UV light, which contributes significantly to the removal of Bmim + . Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Range compensation for backscattering measurements in the difference-frequency nearfield of a parametric sonar.

    PubMed

    Foote, Kenneth G

    2012-05-01

    Measurement of acoustic backscattering properties of targets requires removal of the range dependence of echoes. This process is called range compensation. For conventional sonars making measurements in the transducer farfield, the compensation removes effects of geometrical spreading and absorption. For parametric sonars consisting of a parametric acoustic transmitter and a conventional-sonar receiver, two additional range dependences require compensation when making measurements in the nonlinearly generated difference-frequency nearfield: an apparently increasing source level and a changing beamwidth. General expressions are derived for range compensation functions in the difference-frequency nearfield of parametric sonars. These are evaluated numerically for a parametric sonar whose difference-frequency band, effectively 1-6 kHz, is being used to observe Atlantic herring (Clupea harengus) in situ. Range compensation functions for this sonar are compared with corresponding functions for conventional sonars for the cases of single and multiple scatterers. Dependences of these range compensation functions on the parametric sonar transducer shape, size, acoustic power density, and hydrography are investigated. Parametric range compensation functions, when applied with calibration data, will enable difference-frequency echoes to be expressed in physical units of volume backscattering, and backscattering spectra, including fish-swimbladder-resonances, to be analyzed.

  19. Sensitivity of atmospheric aerosol scavenging to precipitation intensity and frequency in the context of global climate change

    NASA Astrophysics Data System (ADS)

    Hou, Pei; Wu, Shiliang; McCarty, Jessica L.; Gao, Yang

    2018-06-01

    Wet deposition driven by precipitation is an important sink for atmospheric aerosols and soluble gases. We investigate the sensitivity of atmospheric aerosol lifetimes to precipitation intensity and frequency in the context of global climate change. Our sensitivity model simulations, through some simplified perturbations to precipitation in the GEOS-Chem model, show that the removal efficiency and hence the atmospheric lifetime of aerosols have significantly higher sensitivities to precipitation frequencies than to precipitation intensities, indicating that the same amount of precipitation may lead to different removal efficiencies of atmospheric aerosols. Combining the long-term trends of precipitation patterns for various regions with the sensitivities of atmospheric aerosol lifetimes to various precipitation characteristics allows us to examine the potential impacts of precipitation changes on atmospheric aerosols. Analyses based on an observational dataset show that precipitation frequencies in some regions have decreased in the past 14 years, which might increase the atmospheric aerosol lifetimes in those regions. Similar analyses based on multiple reanalysis meteorological datasets indicate that the changes of precipitation intensity and frequency over the past 30 years can lead to perturbations in the atmospheric aerosol lifetimes by 10 % or higher at the regional scale.

  20. Theoretical DFT study on spectroscopic signature and molecular dynamics of neurotransmitter and effect of hydrogen removal

    NASA Astrophysics Data System (ADS)

    Mukherjee, V.; Singh, N. P.; Yadav, R. A.

    2013-04-01

    Vibrational spectroscopic study has been made for the serotonin molecule and its deprotonated form. The Infrared and Raman spectra in optimum geometry of these two molecules are calculated using density functional theorem and the normal modes are assigned using potential energy distributions (PEDs) which are calculated using normal coordinate analysis method. The vibrational frequencies of these two molecules are reported and a comparison has been made. The effect of removal of the hydrogen atom from the serotonin molecule upon its geometry and vibrational frequencies are studied. Electronic structures of these two molecules are also studied using natural bond orbital (NBO) analysis. Theoretical Raman spectrum of serotonin at different exciting laser frequencies and at different temperatures are obtained and the results are discussed. Present study reveals that some wrong assignments had been made for serotonin molecule in earlier study.

  1. Helminth eggs inactivation efficiency by faecal sludge dewatering and co-composting in tropical climates.

    PubMed

    Koné, Doulaye; Cofie, Olufunke; Zurbrügg, Christian; Gallizzi, Katharina; Moser, Daya; Drescher, Silke; Strauss, Martin

    2007-11-01

    This study investigates helminth eggs removal and inactivation efficiency in a treatment process combining faecal sludge (FS) dewatering and subsequent co-composting with organic solid waste as a function of windrow turning frequency. Fresh public toilet sludge and septage mixed at a 1:2 ratio were dewatered on a drying bed. Biosolids with initial loads of 25-83 helminth eggs/g total solids (TS) were mixed with solid waste as bulking material for co-composting at a 1:2 volume ratio. Two replicate sets of compost heaps were mounted in parallel and turned at different frequencies during the active composting period: (i) once every 3 days and (ii) once every 10 days. Turning frequency had no effect on helminth eggs removal efficiency. In both setups, helminth eggs were reduced to <1 viable egg/g TS, thereby complying with the WHO guidelines 2006 for the safe reuse of FS.

  2. Sound pressure gain produced by the human middle ear.

    PubMed

    Kurokawa, H; Goode, R L

    1995-10-01

    The acoustic function of the middle ear is to match sound passing from the low impedance of air to the high impedance of cochlear fluid. Little information is available on the actual middle ear pressure gain in human beings. This article describes experiments on middle ear pressure gain in six fresh human temporal bones. Stapes footplate displacement and phase were measured with a laser Doppler vibrometer before and after removal of the tympanic membrane, malleus, and incus. Acoustic insulation of the round window with clay was performed. Umbo displacement was also measured before tympanic membrane removal to assess baseline tympanic membrane function. The middle ear has its major gain in the lower frequencies, with a peak near 0.9 kHz. The mean gain was 23.0 dB below 1.0 kHz, the resonant frequency of the middle ear; the mean peak gain was 26.6 dB. Above 1.0 kHz, the second pressure gain decreased at a rate of -8.6 dB/octave, with a mean gain of 6.5 dB at 4.0 kHz. Only a small amount of gain was present above 7.0 kHz. Significant individual differences in pressure gain were found between ears that appeared related to variations in tympanic membrane function and not to variations in cochlear impedance.

  3. A Robust Self-Alignment Method for Ship's Strapdown INS Under Mooring Conditions

    PubMed Central

    Sun, Feng; Lan, Haiyu; Yu, Chunyang; El-Sheimy, Naser; Zhou, Guangtao; Cao, Tong; Liu, Hang

    2013-01-01

    Strapdown inertial navigation systems (INS) need an alignment process to determine the initial attitude matrix between the body frame and the navigation frame. The conventional alignment process is to compute the initial attitude matrix using the gravity and Earth rotational rate measurements. However, under mooring conditions, the inertial measurement unit (IMU) employed in a ship's strapdown INS often suffers from both the intrinsic sensor noise components and the external disturbance components caused by the motions of the sea waves and wind waves, so a rapid and precise alignment of a ship's strapdown INS without any auxiliary information is hard to achieve. A robust solution is given in this paper to solve this problem. The inertial frame based alignment method is utilized to adapt the mooring condition, most of the periodical low-frequency external disturbance components could be removed by the mathematical integration and averaging characteristic of this method. A novel prefilter named hidden Markov model based Kalman filter (HMM-KF) is proposed to remove the relatively high-frequency error components. Different from the digital filters, the HMM-KF barely cause time-delay problem. The turntable, mooring and sea experiments favorably validate the rapidness and accuracy of the proposed self-alignment method and the good de-noising performance of HMM-KF. PMID:23799492

  4. Uniform Foam Crush Testing for Multi-Mission Earth Entry Vehicle Impact Attenuation

    NASA Technical Reports Server (NTRS)

    Patterson, Byron W.; Glaab, Louis J.

    2012-01-01

    Multi-Mission Earth Entry Vehicles (MMEEVs) are blunt-body vehicles designed with the purpose of transporting payloads from outer space to the surface of the Earth. To achieve high-reliability and minimum weight, MMEEVs avoid use of limited-reliability systems, such as parachutes and retro-rockets, instead using built-in impact attenuators to absorb energy remaining at impact to meet landing loads requirements. The Multi-Mission Systems Analysis for Planetary Entry (M-SAPE) parametric design tool is used to facilitate the design of MMEEVs and develop the trade space. Testing was conducted to characterize the material properties of several candidate impact foam attenuators to enhance M-SAPE analysis. In the current effort, four different Rohacell foams are tested at three different, uniform, strain rates (approximately 0.17, approximately 100, approximately 13,600%/s). The primary data analysis method uses a global data smoothing technique in the frequency domain to remove noise and system natural frequencies. The results from the data indicate that the filter and smoothing technique are successful in identifying the foam crush event and removing aberrations. The effect of strain rate increases with increasing foam density. The 71-WF-HT foam may support Mars Sample Return requirements. Several recommendations to improve the drop tower test technique are identified.

  5. Periodontal treatment with the frequency-doubled Alexandrite laser in dogs

    NASA Astrophysics Data System (ADS)

    Rechmann, Peter; Hennig, Thomas; Reichart, Peter

    2000-03-01

    While earlier periodontal investigations have proved the frequency doubled Alexandrite laser to eliminate efficiently and selectively dental calculus as well as bacteria the aim of this study was to demonstrate the safety of this laser for removal of dental calculus with respect to the dental pulp. Four adult Labrador dogs were treated with a frequency doubled Alexandrite laser (laboratory prototype, q-switched, fiber guided, wavelength 377 nm, pulse duration 1 microsecond, pulse repetition rate 70 Hz, water cooling) to remove dental calculus. After performing a modified Widman flap procedure the buccal surface of nine teeth in the lower and upper right jaw were irradiated for four minutes per tooth. Three different laser fluences up to four times higher than the fluence required for calculus removal were used (1.5, 3 and 6 J/cm2). At three other sites of the right jaw deep cavities were prepared with a dental drill and filled with compomere material (DyractR, Dentsply, Germany) to serve as a positive control with regard to possible pulpal reactions. The corresponding teeth of the lower and upper left jaw served as controls. Animals were sacrificed one day, one week, four weeks and six weeks after treatment. Teeth were separated, fixed in formalin and decalcified. After embedding and sectioning the histological sections were stained and investigated by a totally blinded investigator (P.A.R). Histological investigations revealed that irradiation with the frequency doubled Alexandrite laser for periodontal treatment with fluences of 1.5 J/cm2 -- those fluences necessary for the selective removal of dental calculus and microbial plaque -- had no adverse side effects to the pulpal tissues. Moreover this pulpal safety study demonstrated that even applying fluences two or four times higher than those suggested for calculus removal do not lead to observable changes or alterations in the odontoblast cell layer or the pulpal tissues. No inflammatory reactions and no differences between irradiated and control teeth occurred, while the positive controls showed reactions in the odontoblast cell layer and the connective pulpal tissue.

  6. Evaluation of an Electrostatic Dust Removal System with Potential Application in Next-Step Fusion Devices

    NASA Technical Reports Server (NTRS)

    Friesen, F. Q. L.; John, B.; Skinner, C. H.; Roquemore, A. L.; Calle, C. I.

    2011-01-01

    The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 cu mm volume of carbon and tungsten particles were moved in under 5 seconds. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon, and the change in particle distribution over short timescales 1 s).

  7. Cleaning of optical surfaces by capacitively coupled RF discharge plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yadav, P. K., E-mail: praveenyadav@rrcat.gov.in; Rai, S. K.; Nayak, M.

    2014-04-24

    In this paper, we report cleaning of carbon capped molybdenum (Mo) thin film by in-house developed radio frequency (RF) plasma reactor, at different powers and exposure time. Carbon capped Mo films were exposed to oxygen plasma for different durations at three different power settings, at a constant pressure. After each exposure, the thickness of the carbon layer and the roughness of the film were determined by hard x-ray reflectivity measurements. It was observed that most of the carbon film got removed in first 15 minutes exposure. A high density layer formed on top of the Mo film was also observedmore » and it was noted that this layer cannot be removed by successive exposures at different powers. A significant improvement in interface roughness with a slight improvement in top film roughness was observed. The surface roughness of the exposed and unexposed samples was also confirmed by atomic force microscopy measurements.« less

  8. In vivo impact testing on a lengthened femur with external fixation: a future option for the non-invasive monitoring of fracture healing?

    PubMed

    Mattei, Lorenza; Di Puccio, Francesca; Marchetti, Stefano

    2018-05-01

    Non-invasive methods for assessing fracture healing are crucial for biomedical engineers. An approach based on mechanical vibrations was tried out in the 1990s, but was soon abandoned due to insufficiently advanced technologies. The same approach is re-proposed in the present study in order to monitor the healing process of a lengthened femur with an external fixator. The pins screwed into the bone were exploited for the impact testing (IT) to excite the bone and capture its response. Transmission through the soft tissues was thus prevented, and the quality of the signals was improved. Impact tests were performed every three to four weeks for five months. Unfortunately, after seven weeks, some pins were removed due to infection, and thus, the system was modified. Two different configurations were considered: before and after pin removal. An additional configuration was examined in the last two sessions, when the fixator body was removed, while four pins were left in the femur. The evolution of the frequency response function and of the resonant frequencies of the system were analysed for the duration of the monitoring period. The IT results were compared to the indications provided by X-ray images. During the evolution of the callus from the soft phase to the woven bone, the resonant frequencies of the system were found to increase by approximately 2-3% per week. The largest increase (approx. 22%) was observed for the first resonant frequency. After formation of the woven bone, the vibratory response remained almost the same, suggesting that the healing assessment could be related to the relative variation in the resonant frequencies. The results presented support the application of the IT approach for fracture healing assessment. © 2018 The Author(s).

  9. Causes and Recommendations for Unanticipated Ink Retention Following Tattoo Removal Treatment

    PubMed Central

    Chen, Cynthia L.; Desai, Alpesh; Desai, Tejas

    2013-01-01

    While placement of ink into the skin is a long-standing tradition, patients are now seeking tattoo removal on a more frequent basis. Once considered acceptable removal options, tattoo ink removal via physical destruction included dermabrasion, chemical destruction, salabrasion, thermal destruction, and cryotherapy. Now these options are used extremely infrequently. These modalities provided unpredictable results and often required prolonged healing times and left patients with skin discoloration, pain, scarring, and ink retention. Even the widely adopted use of lasers, now considered the gold standard method, offers some level of unpredictability surrounding the natural progression of ink resolution. Multiple factors need to be taken into consideration when successfully removing tattoo pigment including the modalities used, number and frequency of treatments, proper device technique, and physiological barriers to tattoo removal. This paper serves to elucidate the common causes of ink retention following tattoo removal treatment with recommendations on how best to address this relatively common occurrence. PMID:23882312

  10. Soil, vegetation, and seed bank of a Sonoran Desert ecosystem along an exotic plant (Pennisetum ciliare) treatment gradient.

    PubMed

    Abella, Scott R; Chiquoine, Lindsay P; Backer, Dana M

    2013-10-01

    Ecological conditions following removal of exotic plants are a key part of comprehensive environmental management strategies to combat exotic plant invasions. We examined ecological conditions following removal of the management-priority buffelgrass (Pennisetum ciliare) in Saguaro National Park of the North American Sonoran Desert. We assessed soil, vegetation, and soil seed banks on seven buffelgrass site types: five different frequencies of buffelgrass herbicide plus hand removal treatments (ranging from 5 years of annual treatment to a single year of treatment), untreated sites, and non-invaded sites, with three replicates for each of the seven site types. The 22 measured soil properties (e.g., pH) differed little among sites. Regarding vegetation, buffelgrass cover was low (≤1% median cover), or absent, across all treated sites but was high (10-70%) in untreated sites. Native vegetation cover, diversity, and composition were indistinguishable across site types. Species composition was dominated by native species (>93% relative cover) across all sites except untreated buffelgrass sites. Most (38 species, 93%) of the 41 species detected in soil seed banks were native, and native seed density did not differ significantly across sites. Results suggest that: (1) buffelgrass cover was minimal across treated sites; (2) aside from high buffelgrass cover in untreated sites, ecological conditions were largely indistinguishable across sites; (3) soil seed banks harbored ≥12 species that were frequent in the aboveground vegetation; and (4) native species dominated post-treatment vegetation composition, and removing buffelgrass did not result in replacement by other exotic species.

  11. Soil, Vegetation, and Seed Bank of a Sonoran Desert Ecosystem Along an Exotic Plant ( Pennisetum ciliare) Treatment Gradient

    NASA Astrophysics Data System (ADS)

    Abella, Scott R.; Chiquoine, Lindsay P.; Backer, Dana M.

    2013-10-01

    Ecological conditions following removal of exotic plants are a key part of comprehensive environmental management strategies to combat exotic plant invasions. We examined ecological conditions following removal of the management-priority buffelgrass ( Pennisetum ciliare) in Saguaro National Park of the North American Sonoran Desert. We assessed soil, vegetation, and soil seed banks on seven buffelgrass site types: five different frequencies of buffelgrass herbicide plus hand removal treatments (ranging from 5 years of annual treatment to a single year of treatment), untreated sites, and non-invaded sites, with three replicates for each of the seven site types. The 22 measured soil properties (e.g., pH) differed little among sites. Regarding vegetation, buffelgrass cover was low (≤1 % median cover), or absent, across all treated sites but was high (10-70 %) in untreated sites. Native vegetation cover, diversity, and composition were indistinguishable across site types. Species composition was dominated by native species (>93 % relative cover) across all sites except untreated buffelgrass sites. Most (38 species, 93 %) of the 41 species detected in soil seed banks were native, and native seed density did not differ significantly across sites. Results suggest that: (1) buffelgrass cover was minimal across treated sites; (2) aside from high buffelgrass cover in untreated sites, ecological conditions were largely indistinguishable across sites; (3) soil seed banks harbored ≥12 species that were frequent in the aboveground vegetation; and (4) native species dominated post-treatment vegetation composition, and removing buffelgrass did not result in replacement by other exotic species.

  12. A bandpass filter for the enhancement of an X-ray reconstruction of the tissue in the spinal canal

    NASA Technical Reports Server (NTRS)

    Reed, I. S.; Glenn, W. V.; Kwoh, Y. S.; Truong, T. K.

    1980-01-01

    In this communication, a new bandpass reconstruction filter is developed to partially remove the low spatial frequencies of the bone and the soft tissue in an X-ray reconstruction of a lumbar spine. This partial removal of the low frequencies suppresses the bony vertebral body and the soft tissue components within the projections of actual clinical data. It also has the effect of enhancing the sharp edges of the fatty tissue surrounding the spinal cord region. The intent of this effort is to directly visualize the spinal cord without the need for water-soluble contrast (e.g., metrizamide) to be installed through lumbar punctures.

  13. A statistical package for computing time and frequency domain analysis

    NASA Technical Reports Server (NTRS)

    Brownlow, J.

    1978-01-01

    The spectrum analysis (SPA) program is a general purpose digital computer program designed to aid in data analysis. The program does time and frequency domain statistical analyses as well as some preanalysis data preparation. The capabilities of the SPA program include linear trend removal and/or digital filtering of data, plotting and/or listing of both filtered and unfiltered data, time domain statistical characterization of data, and frequency domain statistical characterization of data.

  14. 75 FR 71446 - Agency Information Collection Activities; Proposed Collection; Comment Request; Reports of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-23

    ... information regarding these corrections and removals and to determine whether recall action is adequate... Annual Reporting Burden\\1\\ Annual 21 CFR section Number of frequency per Total annual Hours per Total... Average Annual Recordkeeping Burden \\1\\ Annual 21 CFR Section Number of frequency per Total annual Hours...

  15. Determining Young's Modulus by Measuring Guitar String Frequency

    ERIC Educational Resources Information Center

    Polak, Robert D.; Davenport, Adam R. V.; Fischer, Andrew; Rafferty, Jared

    2018-01-01

    Values for physical constants are commonly given as abstractions without building strong intuition, and are too often utilized solely in the pursuit of more easily conceptualized properties. The goal of this experiment is to remove the obscurity behind Young's modulus by exploring the phenomena associated with it--namely, the frequency of a…

  16. High Resolution Topography of Age-Related Changes in Non-Rapid Eye Movement Sleep Electroencephalography

    PubMed Central

    Sprecher, Kate E.; Riedner, Brady A.; Smith, Richard F.; Tononi, Giulio; Davidson, Richard J.; Benca, Ruth M.

    2016-01-01

    Sleeping brain activity reflects brain anatomy and physiology. The aim of this study was to use high density (256 channel) electroencephalography (EEG) during sleep to characterize topographic changes in sleep EEG power across normal aging, with high spatial resolution. Sleep was evaluated in 92 healthy adults aged 18–65 years old using full polysomnography and high density EEG. After artifact removal, spectral power density was calculated for standard frequency bands for all channels, averaged across the NREM periods of the first 3 sleep cycles. To quantify topographic changes with age, maps were generated of the Pearson’s coefficient of the correlation between power and age at each electrode. Significant correlations were determined by statistical non-parametric mapping. Absolute slow wave power declined significantly with increasing age across the entire scalp, whereas declines in theta and sigma power were significant only in frontal regions. Power in fast spindle frequencies declined significantly with increasing age frontally, whereas absolute power of slow spindle frequencies showed no significant change with age. When EEG power was normalized across the scalp, a left centro-parietal region showed significantly less age-related decline in power than the rest of the scalp. This partial preservation was particularly significant in the slow wave and sigma bands. The effect of age on sleep EEG varies substantially by region and frequency band. This non-uniformity should inform the design of future investigations of aging and sleep. This study provides normative data on the effect of age on sleep EEG topography, and provides a basis from which to explore the mechanisms of normal aging as well as neurodegenerative disorders for which age is a risk factor. PMID:26901503

  17. Global analysis of depletion and recovery of seabed biota after bottom trawling disturbance.

    PubMed

    Hiddink, Jan Geert; Jennings, Simon; Sciberras, Marija; Szostek, Claire L; Hughes, Kathryn M; Ellis, Nick; Rijnsdorp, Adriaan D; McConnaughey, Robert A; Mazor, Tessa; Hilborn, Ray; Collie, Jeremy S; Pitcher, C Roland; Amoroso, Ricardo O; Parma, Ana M; Suuronen, Petri; Kaiser, Michel J

    2017-08-01

    Bottom trawling is the most widespread human activity affecting seabed habitats. Here, we collate all available data for experimental and comparative studies of trawling impacts on whole communities of seabed macroinvertebrates on sedimentary habitats and develop widely applicable methods to estimate depletion and recovery rates of biota after trawling. Depletion of biota and trawl penetration into the seabed are highly correlated. Otter trawls caused the least depletion, removing 6% of biota per pass and penetrating the seabed on average down to 2.4 cm, whereas hydraulic dredges caused the most depletion, removing 41% of biota and penetrating the seabed on average 16.1 cm. Median recovery times posttrawling (from 50 to 95% of unimpacted biomass) ranged between 1.9 and 6.4 y. By accounting for the effects of penetration depth, environmental variation, and uncertainty, the models explained much of the variability of depletion and recovery estimates from single studies. Coupled with large-scale, high-resolution maps of trawling frequency and habitat, our estimates of depletion and recovery rates enable the assessment of trawling impacts on unprecedented spatial scales.

  18. A rapid and low energy consumption method to decolorize the high concentration triphenylmethane dye wastewater: operational parameters optimization for the ultrasonic-assisted ozone oxidation process.

    PubMed

    Zhou, Xian-Jiao; Guo, Wan-Qian; Yang, Shan-Shan; Ren, Nan-Qi

    2012-02-01

    This research set up an ultrasonic-assisted ozone oxidation process (UAOOP) to decolorize the triphenylmethane dyes wastewater. Five factors - temperature, initial pH, reaction time, ultrasonic power (low frequency 20 kHz), and ozone concentration - were investigated. Response surface methodology was used to find out the major factors influencing color removal rate and the interactions between these factors, and optimized the operating parameters as well. Under the experimental conditions: reaction temperature 39.81 °C, initial pH 5.29, ultrasonic power 60 W and ozone concentration 0.17 g/L, the highest color removals were achieved with 10 min reaction time and the initial concentration of the MG solution was 1000 mg/L. The optimal results indicated that the UAOOP was a rapid, efficient and low energy consumption technique to decolorize the high concentration MG wastewater. The predicted model was approximately in accordance with the experimental cases with correlation coefficients R(2) and R(adj)(2) of 0.9103 and 0.8386. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  19. Global analysis of depletion and recovery of seabed biota after bottom trawling disturbance

    PubMed Central

    Hiddink, Jan Geert; Jennings, Simon; Sciberras, Marija; Szostek, Claire L.; Hughes, Kathryn M.; Ellis, Nick; Rijnsdorp, Adriaan D.; McConnaughey, Robert A.; Mazor, Tessa; Hilborn, Ray; Collie, Jeremy S.; Pitcher, C. Roland; Amoroso, Ricardo O.; Parma, Ana M.; Suuronen, Petri; Kaiser, Michel J.

    2017-01-01

    Bottom trawling is the most widespread human activity affecting seabed habitats. Here, we collate all available data for experimental and comparative studies of trawling impacts on whole communities of seabed macroinvertebrates on sedimentary habitats and develop widely applicable methods to estimate depletion and recovery rates of biota after trawling. Depletion of biota and trawl penetration into the seabed are highly correlated. Otter trawls caused the least depletion, removing 6% of biota per pass and penetrating the seabed on average down to 2.4 cm, whereas hydraulic dredges caused the most depletion, removing 41% of biota and penetrating the seabed on average 16.1 cm. Median recovery times posttrawling (from 50 to 95% of unimpacted biomass) ranged between 1.9 and 6.4 y. By accounting for the effects of penetration depth, environmental variation, and uncertainty, the models explained much of the variability of depletion and recovery estimates from single studies. Coupled with large-scale, high-resolution maps of trawling frequency and habitat, our estimates of depletion and recovery rates enable the assessment of trawling impacts on unprecedented spatial scales. PMID:28716926

  20. Surface microroughness of ion-beam etched optical surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savvides, N.

    2005-03-01

    Ion-beam etching (IBE) and ion-beam figuring techniques using low-energy ion-beam sources have been applied for more than ten years in the fabrication and finishing of extremely smooth high-performance optics. We used optical interferometric techniques and atomic force microscopy to study the evolution of the surface root-mean-square (rms) microroughness, Rq, as a function of depth of a material removed (0-3000 nm) by a broad ion-beam source (Ar{sup +} ions of energy 600 eV and ion current density of 1 mA cm{sup -2}). Highly polished samples of fused silica and Zerodur (Rq{approx}3.5 A) showed a small decrease in microroughness (to 2.5 A)more » after 3000-nm IBE removal while an ultrapolished single-crystal sapphire sample (Rq{approx}1 A rms) retained its very low microroughness during IBE. Power spectral density functions over the spatial frequency interval of measurement (f=5x10{sup -3}-25 {mu}m{sup -1}) indicate that the IBE surfaces have minimal subsurface damage and low optical scatter.« less

  1. Time-frequency peak filtering for random noise attenuation of magnetic resonance sounding signal

    NASA Astrophysics Data System (ADS)

    Lin, Tingting; Zhang, Yang; Yi, Xiaofeng; Fan, Tiehu; Wan, Ling

    2018-05-01

    When measuring in a geomagnetic field, the method of magnetic resonance sounding (MRS) is often limited because of the notably low signal-to-noise ratio (SNR). Most current studies focus on discarding spiky noise and power-line harmonic noise cancellation. However, the effects of random noise should not be underestimated. The common method for random noise attenuation is stacking, but collecting multiple recordings merely to suppress random noise is time-consuming. Moreover, stacking is insufficient to suppress high-level random noise. Here, we propose the use of time-frequency peak filtering for random noise attenuation, which is performed after the traditional de-spiking and power-line harmonic removal method. By encoding the noisy signal with frequency modulation and estimating the instantaneous frequency using the peak of the time-frequency representation of the encoded signal, the desired MRS signal can be acquired from only one stack. The performance of the proposed method is tested on synthetic envelope signals and field data from different surveys. Good estimations of the signal parameters are obtained at different SNRs. Moreover, an attempt to use the proposed method to handle a single recording provides better results compared to 16 stacks. Our results suggest that the number of stacks can be appropriately reduced to shorten the measurement time and improve the measurement efficiency.

  2. Two-time scale fatigue modelling: application to damage

    NASA Astrophysics Data System (ADS)

    Devulder, Anne; Aubry, Denis; Puel, Guillaume

    2010-05-01

    A temporal multiscale modelling applied to fatigue damage evolution in cortical bone is presented. Microdamage accumulation in cortical bone, ensued from daily activities, leads to impaired mechanical properties, in particular by reducing the bone stiffness and inducing fatigue. However, bone damage is also known as a stimulus to bone remodelling, whose aim is to repair and generate new bone, adapted to its environment. This biological process by removing fatigue damage seems essential to the skeleton lifetime. As daily activities induce high frequency cycles (about 10,000 cycles a day), identifying two-time scale is very fruitful: a fast one connected with the high frequency cyclic loading and a slow one related to a quasi-static loading. A scaling parameter is defined between the intrinsic time (bone lifetime of several years) and the high frequency loading (few seconds). An asymptotic approach allows to decouple the two scales and to take into account history effects (Guennouni and Aubry in CR Acad Sci Paris Ser II 20:1765-1767, 1986). The method is here applied to a simple case of fatigue damage and a real cortical bone microstructure. A significant reduction in the amount of computation time in addition to a small computational error between time homogenized and non homogenized models are obtained. This method seems thus to give new perspectives to assess fatigue damage and, with regard to bone, to give a better understanding of bone remodelling.

  3. A real-time 3D range image sensor based on a novel tip-tilt-piston micromirror and dual frequency phase shifting

    NASA Astrophysics Data System (ADS)

    Skotheim, Øystein; Schumann-Olsen, Henrik; Thorstensen, Jostein; Kim, Anna N.; Lacolle, Matthieu; Haugholt, Karl-Henrik; Bakke, Thor

    2015-03-01

    Structured light is a robust and accurate method for 3D range imaging in which one or more light patterns are projected onto the scene and observed with an off-axis camera. Commercial sensors typically utilize DMD- or LCD-based LED projectors, which produce good results but have a number of drawbacks, e.g. limited speed, limited depth of focus, large sensitivity to ambient light and somewhat low light efficiency. We present a 3D imaging system based on a laser light source and a novel tip-tilt-piston micro-mirror. Optical interference is utilized to create sinusoidal fringe patterns. The setup allows fast and easy control of both the frequency and the phase of the fringe patterns by altering the axes of the micro-mirror. For 3D reconstruction we have adapted a Dual Frequency Phase Shifting method which gives robust range measurements with sub-millimeter accuracy. The use of interference for generating sine patterns provides high light efficiency and good focusing properties. The use of a laser and a bandpass filter allows easy removal of ambient light. The fast response of the micro-mirror in combination with a high-speed camera and real-time processing on the GPU allows highly accurate 3D range image acquisition at video rates.

  4. Monitoring of catalyst performance in CO2 lasers using frequency modulation spectroscopy with diode lasers

    NASA Technical Reports Server (NTRS)

    Wang, Liang-Guo; Sachse, Glen

    1990-01-01

    Closed-cycle CO2 laser operation with removal of O2 and regeneration of CO2 can be achieved by catalytic CO-O2 recombination. Both parametric studies of the optimum catalyst formulation and long-term performance tests require on line monitoring of CO, O2 and CO2 concentrations. There are several existing methods for molecular oxygen detection. These methods are either intrusive (such as electrochemical method or mass spectrometry) or very expensive (such as CARS, UV laser absorption). Researchers demonstrated a high-sensitivity spectroscopic measurement of O2 using the two-tone frequency modulation spectroscopy (FMS) technique with a near infrared GaAlAs diode laser. Besides its inexpensive cost, fast response time, nonintrusive measurements and high sensitivity, this technique may also be used to differentiate between isotopes due to its high spectroscopic resolution. This frequency modulation spectroscopy technique could also be applied for the on-line monitoring of CO and CO2 using InGaAsP diode lasers operation in the 1.55 microns region and H2O in the 1.3 microns region. The existence of single mode optical fibers at the near infrared region makes it possible to combine FMS with optical fiber technology. Optical fiber FMS is particularly suitable for making point-measurements at one or more locations in the CO2 laser/catalyst system.

  5. Method for detecting moment connection fracture using high-frequency transients in recorded accelerations

    USGS Publications Warehouse

    Rodgers, J.E.; Elebi, M.

    2011-01-01

    The 1994 Northridge earthquake caused brittle fractures in steel moment frame building connections, despite causing little visible building damage in most cases. Future strong earthquakes are likely to cause similar damage to the many un-retrofitted pre-Northridge buildings in the western US and elsewhere. Without obvious permanent building deformation, costly intrusive inspections are currently the only way to determine if major fracture damage that compromises building safety has occurred. Building instrumentation has the potential to provide engineers and owners with timely information on fracture occurrence. Structural dynamics theory predicts and scale model experiments have demonstrated that sudden, large changes in structure properties caused by moment connection fractures will cause transient dynamic response. A method is proposed for detecting the building-wide level of connection fracture damage, based on observing high-frequency, fracture-induced transient dynamic responses in strong motion accelerograms. High-frequency transients are short (<1 s), sudden-onset waveforms with frequency content above 25 Hz that are visually apparent in recorded accelerations. Strong motion data and damage information from intrusive inspections collected from 24 sparsely instrumented buildings following the 1994 Northridge earthquake are used to evaluate the proposed method. The method's overall success rate for this data set is 67%, but this rate varies significantly with damage level. The method performs reasonably well in detecting significant fracture damage and in identifying cases with no damage, but fails in cases with few fractures. Combining the method with other damage indicators and removing records with excessive noise improves the ability to detect the level of damage. ?? 2010 Elsevier B.V. All rights reserved.

  6. Enhanced Eddy-Current Detection Of Weld Flaws

    NASA Technical Reports Server (NTRS)

    Van Wyk, Lisa M.; Willenberg, James D.

    1992-01-01

    Mixing of impedances measured at different frequencies reduces noise and helps reveal flaws. In new method, one excites eddy-current probe simultaneously at two different frequencies; usually, one of which integral multiple of other. Resistive and reactive components of impedance of eddy-current probe measured at two frequencies, mixed in computer, and displayed in real time on video terminal of computer. Mixing of measurements obtained at two different frequencies often "cleans up" displayed signal in situations in which band-pass filtering alone cannot: mixing removes most noise, and displayed signal resolves flaws well.

  7. Highly-efficient, frequency-tripled Nd:YAG laser for spaceborne LIDARs

    NASA Astrophysics Data System (ADS)

    Treichel, R.; Hoffmann, H.-D.; Luttmann, J.; Morasch, V.; Nicklaus, K.; Wührer, C.

    2017-11-01

    For a spaceborne lidar a highly reliable, long living and efficient laser source is absolutely essential. Within the frame of the development of a laser source for the backscatter lidar ATLID, which will be flown on EarthCare mission, we setup and tested a predevelopment model of an injection-seeded, diode pumped, frequency tripled, pulsed high power Nd:YAG MOPA laser operating nominally at 100 Hz pulse repetition frequency. We also tested the burst operation mode. The excellent measured performance parameter will be introduced. The oscillator rod is longitudinally pumped from both sides. The oscillator has been operated with three cavity control methods: "Cavity Dither", "Pound-Drever-Hall" and "Adaptive Ramp & Fire". Especially the latter method is very suitable to operate the laser in harsh vibrating environment such in airplanes. The amplifier bases on the InnoSlab design concept. The constant keeping of a moderate fluence in the InnoSlab crystal permits excellent possibilities to scale the pulse energy to several 100 mJ. An innovative pump unit and optics makes the laser performance insensitive to inhomogeneous diode degradation and allows switching of additional redundant diodes. Further key features have been implemented in a FM design concept. The operational lifetime is extended by the implementation of internal redundancies for the most critical parts. The reliability is increased due to the higher margin onto the laser induced damage threshold by a pressurized housing. Additionally air-to-vacuum effects becomes obsolete. A high efficient heat removal concept has been implemented.

  8. Mathematical model of bone drilling for virtual surgery system

    NASA Astrophysics Data System (ADS)

    Alaytsev, Innokentiy K.; Danilova, Tatyana V.; Manturov, Alexey O.; Mareev, Gleb O.; Mareev, Oleg V.

    2018-04-01

    The bone drilling is an essential part of surgeries in ENT and Dentistry. A proper training of drilling machine handling skills is impossible without proper modelling of the drilling process. Utilization of high precision methods like FEM is limited due to the requirement of 1000 Hz update rate for haptic feedback. The study presents a mathematical model of the drilling process that accounts the properties of materials, the geometry and the rotation rate of a burr to compute the removed material volume. The simplicity of the model allows for integrating it in the high-frequency haptic thread. The precision of the model is enough for a virtual surgery system targeted on the training of the basic surgery skills.

  9. Ultrasonic Polishing

    NASA Technical Reports Server (NTRS)

    Gilmore, Randy

    1993-01-01

    The ultrasonic polishing process makes use of the high-frequency (ultrasonic) vibrations of an abradable tool which automatically conforms to the work piece and an abrasive slurry to finish surfaces and edges on complex, highly detailed, close tolerance cavities in materials from beryllium copper to carbide. Applications range from critical deburring of guidance system components to removing EDM recast layers from aircraft engine components to polishing molds for forming carbide cutting tool inserts or injection molding plastics. A variety of materials including tool steels, carbides, and even ceramics can be successfully processed. Since the abradable tool automatically conforms to the work piece geometry, the ultrasonic finishing method described offers a number of important benefits in finishing components with complex geometries.

  10. Removal of ruminal contents followed by restricted feeding does not affect the frequency of luteinizing-hormone pulses in steers

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to determine the effects of removal of ruminal contents and reduced nutrient intake on concentrations of LH in serum of beef cattle. Gonadectomized, male, Angus x Hereford cattle (steers, 402 ± 17 kg) with rumen cannulae were randomly assigned to treatment. Control (C...

  11. Ionization-induced annealing of pre-existing defects in silicon carbide

    DOE PAGES

    Zhang, Yanwen; Sachan, Ritesh; Pakarinen, Olli H.; ...

    2015-08-12

    A long-standing objective in materials research is to find innovative ways to remove preexisting damage and heal fabrication defects or environmentally induced defects in materials. Silicon carbide (SiC) is a fascinating wide-band gap semiconductor for high-temperature, high-power, high-frequency applications. Its high corrosion and radiation resistance makes it a key refractory/structural material with great potential for extremely harsh radiation environments. Here we show that the energy transferred to the electron system of SiC by energetic ions via inelastic ionization processes results in a highly localized thermal spike that can effectively heal preexisting defects and restore the structural order. This work revealsmore » an innovative self-healing process using highly ionizing ions, and it describes a critical aspect to be considered in modeling SiC performance as either a functional or a structural material for device applications or high-radiation environments.« less

  12. Methods for reverberation suppression utilizing dual frequency band imaging.

    PubMed

    Rau, Jochen M; Måsøy, Svein-Erik; Hansen, Rune; Angelsen, Bjørn; Tangen, Thor Andreas

    2013-09-01

    Reverberations impair the contrast resolution of diagnostic ultrasound images. Tissue harmonic imaging is a common method to reduce these artifacts, but does not remove all reverberations. Dual frequency band imaging (DBI), utilizing a low frequency pulse which manipulates propagation of the high frequency imaging pulse, has been proposed earlier for reverberation suppression. This article adds two different methods for reverberation suppression with DBI: the delay corrected subtraction (DCS) and the first order content weighting (FOCW) method. Both methods utilize the propagation delay of the imaging pulse of two transmissions with alternating manipulation pressure to extract information about its depth of first scattering. FOCW further utilizes this information to estimate the content of first order scattering in the received signal. Initial evaluation is presented where both methods are applied to simulated and in vivo data. Both methods yield visual and measurable substantial improvement in image contrast. Comparing DCS with FOCW, DCS produces sharper images and retains more details while FOCW achieves best suppression levels and, thus, highest image contrast. The measured improvement in contrast ranges from 8 to 27 dB for DCS and from 4 dB up to the dynamic range for FOCW.

  13. A Novel Low-Power, High-Performance, Zero-Maintenance Closed-Path Trace Gas Eddy Covariance System with No Water Vapor Dilution or Spectroscopic Corrections

    NASA Astrophysics Data System (ADS)

    Sargent, S.; Somers, J. M.

    2015-12-01

    Trace-gas eddy covariance flux measurement can be made with open-path or closed-path analyzers. Traditional closed-path trace-gas analyzers use multipass absorption cells that behave as mixing volumes, requiring high sample flow rates to achieve useful frequency response. The high sample flow rate and the need to keep the multipass cell extremely clean dictates the use of a fine-pore filter that may clog quickly. A large-capacity filter cannot be used because it would degrade the EC system frequency response. The high flow rate also requires a powerful vacuum pump, which will typically consume on the order of 1000 W. The analyzer must measure water vapor for spectroscopic and dilution corrections. Open-path analyzers are available for methane, but not for nitrous oxide. The currently available methane analyzers have low power consumption, but are very large. Their large size degrades frequency response and disturbs the air flow near the sonic anemometer. They require significant maintenance to keep the exposed multipass optical surfaces clean. Water vapor measurements for dilution and spectroscopic corrections require a separate water vapor analyzer. A new closed-path eddy covariance system for measuring nitrous oxide or methane fluxes provides an elegant solution. The analyzer (TGA200A, Campbell Scientific, Inc.) uses a thermoelectrically-cooled interband cascade laser. Its small sample-cell volume and unique sample-cell configuration (200 ml, 1.5 m single pass) provide excellent frequency response with a low-power scroll pump (240 W). A new single-tube Nafion® dryer removes most of the water vapor, and attenuates fluctuations in the residual water vapor. Finally, a vortex intake assembly eliminates the need for an intake filter without adding volume that would degrade system frequency response. Laboratory testing shows the system attenuates the water vapor dilution term by more than 99% and achieves a half-power band width of 3.5 Hz.

  14. Implications of Using Corn Stalks as a Biofuel Source: A Joint ARS and DOE Project

    NASA Astrophysics Data System (ADS)

    Wilhelm, W. W.; Cushman, J.

    2003-12-01

    Corn stover is a readily source of biomass for cellulosic ethanol production, and may provide additional income for growers. Published research shows that residue removal changes the rate of soil physical, chemical, and biological processes, and in turn, crop growth. Building a sustainable cellulosic ethanol industry based on corn residue requires residue management practices that do not reduce long-term productivity. To develop such systems, impacts of stover removal on the soil and subsequent crops must be quantified. The ARS/DOE Biofuel Project is the cooperative endeavor among scientists from six western Corn Belt US Dept. of Agriculture, Agricultural Research Service (ARS) locations and US Dept. of Energy. The objectives of the project are to determine the influence of stover removal on crop productivity, soil aggregation, quality, carbon content, and seasonal energy balance, and carbon sequestration. When residue is removed soil temperatures fluctuate more and soil water evaporation is greater. Residue removal reduces the amount of soil organic carbon (SOC), but the degree of reduction is highly dependent on degree of tillage, quantity of stover removed, and frequency of stover removal. Of the three cultural factors (stover removal, tillage, and N fertilization) tillage had the greatest effect on amount of corn-derived SOC. No tillage tends to increase the fraction of aggregates in the 2.00 to 0.25 mm size range at all removal rates. Stover harvest reduces corn-derived SOC by 35% compared to retaining stover on the soil averaged over all tillage systems. Corn stover yield has not differed across stover removal treatments in these studies. In the irrigated study, grain yield increased with stover removal. In the rain-fed studies, grain yield has not differed among residue management treatments. Incorporating the biomass ethanol fermentation by-product into a soil with low SOC showed a positive relationship between the amount of lignin added and the subsequent humic acid concentration and aggregate stability. These and future outcomes from this effort will provide DOE and the developing biomass ethanol industry knowledge and guidelines on the environmental and crop productivity consequences of large-scale collection of corn stover.

  15. Intraoperative dorsal language network mapping by using single-pulse electrical stimulation.

    PubMed

    Yamao, Yukihiro; Matsumoto, Riki; Kunieda, Takeharu; Arakawa, Yoshiki; Kobayashi, Katsuya; Usami, Kiyohide; Shibata, Sumiya; Kikuchi, Takayuki; Sawamoto, Nobukatsu; Mikuni, Nobuhiro; Ikeda, Akio; Fukuyama, Hidenao; Miyamoto, Susumu

    2014-09-01

    The preservation of language function during brain surgery still poses a challenge. No intraoperative methods have been established to monitor the language network reliably. We aimed to establish intraoperative language network monitoring by means of cortico-cortical evoked potentials (CCEPs). Subjects were six patients with tumors located close to the arcuate fasciculus (AF) in the language-dominant left hemisphere. Under general anesthesia, the anterior perisylvian language area (AL) was first defined by the CCEP connectivity patterns between the ventrolateral frontal and temporoparietal area, and also by presurgical neuroimaging findings. We then monitored the integrity of the language network by stimulating AL and by recording CCEPs from the posterior perisylvian language area (PL) consecutively during both general anesthesia and awake condition. High-frequency electrical stimulation (ES) performed during awake craniotomy confirmed language function at AL in all six patients. Despite an amplitude decline (≤32%) in two patients, CCEP monitoring successfully prevented persistent language impairment. After tumor removal, single-pulse ES was applied to the white matter tract beneath the floor of the removal cavity in five patients, in order to trace its connections into the language cortices. In three patients in whom high-frequency ES of the white matter produced naming impairment, this "eloquent" subcortical site directly connected AL and PL, judging from the latencies and distributions of cortico- and subcortico-cortical evoked potentials. In conclusion, this study provided the direct evidence that AL, PL, and AF constitute the dorsal language network. Intraoperative CCEP monitoring is clinically useful for evaluating the integrity of the language network. Copyright © 2014 Wiley Periodicals, Inc.

  16. EEG Artifact Removal Using a Wavelet Neural Network

    NASA Technical Reports Server (NTRS)

    Nguyen, Hoang-Anh T.; Musson, John; Li, Jiang; McKenzie, Frederick; Zhang, Guangfan; Xu, Roger; Richey, Carl; Schnell, Tom

    2011-01-01

    !n this paper we developed a wavelet neural network. (WNN) algorithm for Electroencephalogram (EEG) artifact removal without electrooculographic (EOG) recordings. The algorithm combines the universal approximation characteristics of neural network and the time/frequency property of wavelet. We. compared the WNN algorithm with .the ICA technique ,and a wavelet thresholding method, which was realized by using the Stein's unbiased risk estimate (SURE) with an adaptive gradient-based optimal threshold. Experimental results on a driving test data set show that WNN can remove EEG artifacts effectively without diminishing useful EEG information even for very noisy data.

  17. Biochemical polymorphism in Egyptian Baladi cattle and their relationship with other breeds.

    PubMed

    Graml, R; Ohmayer, G; Pirchner, F; Erhard, L; Buchberger, J; Mostageer, A

    1986-01-01

    Gene frequencies were estimated in a sample of Baladi cattle for milk proteins, blood proteins and blood groups. Gene frequency estimates of Bos taurus, Bos indicus and Sanga breeds were assembled from the literature. The gene frequencies were utilized for estimating the genetic distance between the breeds and breed groups. The Egyptian Baladi cattle appeared to be closer to Bos taurus breeds than to the Sanga. They are far removed from Zebus.

  18. Reducing orbital eccentricity of precessing black-hole binaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buonanno, Alessandra; Taracchini, Andrea; Kidder, Lawrence E.

    2011-05-15

    Building initial conditions for generic binary black-hole evolutions which are not affected by initial spurious eccentricity remains a challenge for numerical-relativity simulations. This problem can be overcome by applying an eccentricity-removal procedure which consists of evolving the binary black hole for a couple of orbits, estimating the resulting eccentricity, and then restarting the simulation with corrected initial conditions. The presence of spins can complicate this procedure. As predicted by post-Newtonian theory, spin-spin interactions and precession prevent the binary from moving along an adiabatic sequence of spherical orbits, inducing oscillations in the radial separation and in the orbital frequency. For single-spinmore » binary black holes these oscillations are a direct consequence of monopole-quadrupole interactions. However, spin-induced oscillations occur at approximately twice the orbital frequency, and therefore can be distinguished and disentangled from the initial spurious eccentricity which occurs at approximately the orbital frequency. Taking this into account, we develop a new eccentricity-removal procedure based on the derivative of the orbital frequency and find that it is rather successful in reducing the eccentricity measured in the orbital frequency to values less than 10{sup -4} when moderate spins are present. We test this new procedure using numerical-relativity simulations of binary black holes with mass ratios 1.5 and 3, spin magnitude 0.5, and various spin orientations. The numerical simulations exhibit spin-induced oscillations in the dynamics at approximately twice the orbital frequency. Oscillations of similar frequency are also visible in the gravitational-wave phase and frequency of the dominant l=2, m=2 mode.« less

  19. A High-Frequency Annular-Array Transducer Using an Interdigital Bonded 1-3 Composite

    PubMed Central

    Chabok, Hamid Reza; Cannata, Jonathan M.; Kim, Hyung Ham; Williams, Jay A.; Park, Jinhyoung; Shung, K. Kirk

    2011-01-01

    This paper reports the design, fabrication, and characterization of a 1–3 composite annular-array transducer. An interdigital bonded (IB) 1–3 composite was prepared using two IB operations on a fine-grain piezoelectric ceramic. The final composite had 19-μm-wide posts separated by 6-μm-wide polymer kerfs. A novel method to remove metal electrodes from polymer portions of the 1–3 composite was established to eliminate the need for patterning and aligning the electrode on the composite to the electrodes on a flexible circuit. Unloaded epoxy was used for both the matching and backing layers and a flexible circuit was used for interconnect. A prototype array was successfully fabricated and tested. The results were in reasonable agreement with those predicted by a circuit-analogous model. The average center frequency estimated from the measured pulse-echo responses of array elements was 33.5 MHz and the −6-dB fractional bandwidth was 57%. The average insertion loss recorded was 14.3 dB, and the maximum crosstalk between the nearest-neighbor elements was less than −37 dB. Images of a wire phantom and excised porcine eye were obtained to show the capabilities of the array for high-frequency ultrasound imaging. PMID:21244988

  20. A high-frequency annular-array transducer using an interdigital bonded 1-3 composite.

    PubMed

    Chabok, Hamid Reza; Cannata, Jonathan M; Kim, Hyung Ham; Williams, Jay A; Park, Jinhyoung; Shung, K Kirk

    2011-01-01

    This paper reports the design, fabrication, and characterization of a 1-3 composite annular-array transducer. An interdigital bonded (IB) 1-3 composite was prepared using two IB operations on a fine-grain piezoelectric ceramic. The final composite had 19-μm-wide posts separated by 6-μm-wide polymer kerfs. A novel method to remove metal electrodes from polymer portions of the 1-3 composite was established to eliminate the need for patterning and aligning the electrode on the composite to the electrodes on a flexible circuit. Unloaded epoxy was used for both the matching and backing layers and a flexible circuit was used for interconnect. A prototype array was successfully fabricated and tested. The results were in reasonable agreement with those predicted by a circuit-analogous model. The average center frequency estimated from the measured pulse-echo responses of array elements was 33.5 MHz and the -6-dB fractional bandwidth was 57%. The average insertion loss recorded was 14.3 dB, and the maximum crosstalk between the nearest-neighbor elements was less than -37 dB. Images of a wire phantom and excised porcine eye were obtained to show the capabilities of the array for high-frequency ultrasound imaging.

  1. Electrical and Magnetic Measurements from microHertz to teraHertz (Invited)

    NASA Astrophysics Data System (ADS)

    Olhoeft, G. R.

    2009-12-01

    In making electrical and magnetic measurements, half the problem is the measurement of the properties of the rocks, soils and fluids, and half the problem is duplicating the environment. Equally important with applying a field stimulus and measuring the response are fluid content and chemistry, temperature, pressure, time and other factors. The magnetic properties of Martian soils are not interesting under terrestrial ambient lab temperatures (298 K), but exhibit a very interesting relaxation at Mars ambient temperatures (213 K) which is important in radar sounding. The electrical properties of granite are nearly identical at 523 K vacuum dry and 263 K water saturated which is important in geothermal exploration. The most common zeolite, clinoptilolite, can behave like kaolinite or montmorillonite depending upon salinity and temperature in many of its properties. Making measurements at very high frequencies can make frozen water look like a clear ice cube or a white opaque snowball depending upon grain size scattering and thermal history. Low frequency measurements are more sensitive to chemistry as reactions can't keep up at high frequencies. In situ measurements are more complicated (including effects of heterogeneity and scale), but laboratory measurements allow investigation of more variables to understand process and property controlling factors, including effects of removing the sample from its environment.

  2. A stable frequency comb directly referenced to rubidium electromagnetically induced transparency and two-photon transitions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou, Dong; Wu, Jiutao; Zhang, Shuangyou

    2014-03-17

    We demonstrate an approach to create a stable erbium-fiber-based frequency comb at communication band by directly locking the combs to two rubidium atomic transitions resonances (electromagnetically induced transparency absorption and two-photon absorption), respectively. This approach directly transfers the precision and stability of the atomic transitions to the comb. With its distinguishing feature of compactness by removing the conventional octave-spanning spectrum and f-to-2f beating facilities and the ability to directly control the comb's frequency at the atomic transition frequency, this stable optical comb can be widely used in optical communication, frequency standard, and optical spectroscopy and microscopy.

  3. Frequency Dependence of Helioseismic Measurements of the Center-to-Limb Effect and Flow-induced Travel-time Shifts

    NASA Astrophysics Data System (ADS)

    Chen, Ruizhu; Zhao, Junwei

    2018-02-01

    Time–distance helioseismology measures acoustic travel times to infer the structure and flow field of the solar interior; however, both the mean travel times and the travel-time shifts suffer systematic center-to-limb variations, which complicate the interpretation and inversions of the time–distance measurements. In particular, the center-to-limb variation in travel-time shifts (CtoL effect) has a significant impact on the inference of the Sun’s meridional circulation, and needs to be removed from the helioseismic measurements, although the observational properties and the physical cause of the CtoL effect have yet to be investigated. In this study, we measure the CtoL effect in the frequency domain using Doppler-velocity data from the Solar Dynamics Observatory/Helioseismic and Magnetic Imager, and study its properties as a function of disk-centric distance, travel distance, and frequency of acoustic waves. It is found that the CtoL effect has a significant frequency dependence—it reverses sign at a frequency around 5.4 mHz and reaches maximum at around 4.0 mHz before the sign reversal. The tendency of frequency dependence varies with disk-centric distance in a way that both the sign-reversal frequency and the maximum-value frequency decrease closer to the limb. The variation tendency does not change with travel distance, but the variation magnitude is approximately proportional to travel distance. For comparison, the flow-induced travel-time shifts show little frequency dependence. These observational properties provide more clues on the nature of the CtoL effect, and also possibly lead to new ways of effect-removal for a more robust determination of the deep meridional flow.

  4. BIPM Time Activities Update

    DTIC Science & Technology

    2009-11-01

    transfer technique as GPS PPP and GLONASS Common View, - creation of new statistical tools in order remove outliers in TWSTFT time links, making the...in-view [1] using single- and dual-frequency receivers and TWSTFT links [2-4]. Significant progress has been made in time transfer for clock...of differentially calibrated GLONASS receivers [8]. TWSTFT links are often affected by outliers which are difficult to remove; for safe handling, a

  5. Total variation-based neutron computed tomography

    NASA Astrophysics Data System (ADS)

    Barnard, Richard C.; Bilheux, Hassina; Toops, Todd; Nafziger, Eric; Finney, Charles; Splitter, Derek; Archibald, Rick

    2018-05-01

    We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. In order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. The algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

  6. Signal processing in urodynamics: towards high definition urethral pressure profilometry.

    PubMed

    Klünder, Mario; Sawodny, Oliver; Amend, Bastian; Ederer, Michael; Kelp, Alexandra; Sievert, Karl-Dietrich; Stenzl, Arnulf; Feuer, Ronny

    2016-03-22

    Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) combining enhanced UPP hardware and signal processing algorithms has been developed. In this work, we present the different signal processing steps in HD-UPP and show experimental results from female minipigs. We use a special microtip catheter with high angular pressure resolution and an integrated inclination sensor. Signals from the catheter are filtered and time-correlated artifacts removed. A signal reconstruction algorithm processes pressure data into a detailed pressure image on the urethra's inside. Finally, the pressure distribution on the urethra's outside is calculated through deconvolution. A mathematical model of the urethra is contained in a point-spread-function (PSF) which is identified depending on geometric and material properties of the urethra. We additionally investigate the PSF's frequency response to determine the relevant frequency band for pressure information on the urinary sphincter. Experimental pressure data are spatially located and processed into high resolution pressure images. Artifacts are successfully removed from data without blurring other details. The pressure distribution on the urethra's outside is reconstructed and compared to the one on the inside. Finally, the pressure images are mapped onto the urethral geometry calculated from inclination and position data to provide an integrated image of pressure distribution, anatomical shape, and location. With its advanced sensing capabilities, the novel microtip catheter collects an unprecedented amount of urethral pressure data. Through sequential signal processing steps, physicians are provided with detailed information on the pressure distribution in and around the urethra. Therefore, HD-UPP overcomes many current limitations of conventional UPP and offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct anatomical location. This could enable the development of focal therapy approaches in the treatment of SUI.

  7. Kmeans-ICA based automatic method for ocular artifacts removal in a motorimagery classification.

    PubMed

    Bou Assi, Elie; Rihana, Sandy; Sawan, Mohamad

    2014-01-01

    Electroencephalogram (EEG) recordings aroused as inputs of a motor imagery based BCI system. Eye blinks contaminate the spectral frequency of the EEG signals. Independent Component Analysis (ICA) has been already proved for removing these artifacts whose frequency band overlap with the EEG of interest. However, already ICA developed methods, use a reference lead such as the ElectroOculoGram (EOG) to identify the ocular artifact components. In this study, artifactual components were identified using an adaptive thresholding by means of Kmeans clustering. The denoised EEG signals have been fed into a feature extraction algorithm extracting the band power, the coherence and the phase locking value and inserted into a linear discriminant analysis classifier for a motor imagery classification.

  8. Separating Movement and Gravity Components in an Acceleration Signal and Implications for the Assessment of Human Daily Physical Activity

    PubMed Central

    van Hees, Vincent T.; Gorzelniak, Lukas; Dean León, Emmanuel Carlos; Eder, Martin; Pias, Marcelo; Taherian, Salman; Ekelund, Ulf; Renström, Frida; Franks, Paul W.; Horsch, Alexander; Brage, Søren

    2013-01-01

    Introduction Human body acceleration is often used as an indicator of daily physical activity in epidemiological research. Raw acceleration signals contain three basic components: movement, gravity, and noise. Separation of these becomes increasingly difficult during rotational movements. We aimed to evaluate five different methods (metrics) of processing acceleration signals on their ability to remove the gravitational component of acceleration during standardised mechanical movements and the implications for human daily physical activity assessment. Methods An industrial robot rotated accelerometers in the vertical plane. Radius, frequency, and angular range of motion were systematically varied. Three metrics (Euclidian norm minus one [ENMO], Euclidian norm of the high-pass filtered signals [HFEN], and HFEN plus Euclidean norm of low-pass filtered signals minus 1 g [HFEN+]) were derived for each experimental condition and compared against the reference acceleration (forward kinematics) of the robot arm. We then compared metrics derived from human acceleration signals from the wrist and hip in 97 adults (22–65 yr), and wrist in 63 women (20–35 yr) in whom daily activity-related energy expenditure (PAEE) was available. Results In the robot experiment, HFEN+ had lowest error during (vertical plane) rotations at an oscillating frequency higher than the filter cut-off frequency while for lower frequencies ENMO performed better. In the human experiments, metrics HFEN and ENMO on hip were most discrepant (within- and between-individual explained variance of 0.90 and 0.46, respectively). ENMO, HFEN and HFEN+ explained 34%, 30% and 36% of the variance in daily PAEE, respectively, compared to 26% for a metric which did not attempt to remove the gravitational component (metric EN). Conclusion In conclusion, none of the metrics as evaluated systematically outperformed all other metrics across a wide range of standardised kinematic conditions. However, choice of metric explains different degrees of variance in daily human physical activity. PMID:23626718

  9. Separating movement and gravity components in an acceleration signal and implications for the assessment of human daily physical activity.

    PubMed

    van Hees, Vincent T; Gorzelniak, Lukas; Dean León, Emmanuel Carlos; Eder, Martin; Pias, Marcelo; Taherian, Salman; Ekelund, Ulf; Renström, Frida; Franks, Paul W; Horsch, Alexander; Brage, Søren

    2013-01-01

    Human body acceleration is often used as an indicator of daily physical activity in epidemiological research. Raw acceleration signals contain three basic components: movement, gravity, and noise. Separation of these becomes increasingly difficult during rotational movements. We aimed to evaluate five different methods (metrics) of processing acceleration signals on their ability to remove the gravitational component of acceleration during standardised mechanical movements and the implications for human daily physical activity assessment. An industrial robot rotated accelerometers in the vertical plane. Radius, frequency, and angular range of motion were systematically varied. Three metrics (Euclidian norm minus one [ENMO], Euclidian norm of the high-pass filtered signals [HFEN], and HFEN plus Euclidean norm of low-pass filtered signals minus 1 g [HFEN+]) were derived for each experimental condition and compared against the reference acceleration (forward kinematics) of the robot arm. We then compared metrics derived from human acceleration signals from the wrist and hip in 97 adults (22-65 yr), and wrist in 63 women (20-35 yr) in whom daily activity-related energy expenditure (PAEE) was available. In the robot experiment, HFEN+ had lowest error during (vertical plane) rotations at an oscillating frequency higher than the filter cut-off frequency while for lower frequencies ENMO performed better. In the human experiments, metrics HFEN and ENMO on hip were most discrepant (within- and between-individual explained variance of 0.90 and 0.46, respectively). ENMO, HFEN and HFEN+ explained 34%, 30% and 36% of the variance in daily PAEE, respectively, compared to 26% for a metric which did not attempt to remove the gravitational component (metric EN). In conclusion, none of the metrics as evaluated systematically outperformed all other metrics across a wide range of standardised kinematic conditions. However, choice of metric explains different degrees of variance in daily human physical activity.

  10. Removal of phenanthrene in aqueous solution containing photon competitors by TiO2-C-Ag film supported on fiberglass.

    PubMed

    González-Ramírez, Denisse Fabiola; Ávila-Pérez, Pedro; Torres-Bustillos, Luis G; Aguilar-López, Ricardo; Montes-Horcasitas, María C; Esparza-García, Fernando J; Rodríguez-Vázquez, Refugio

    2017-07-03

    Surface interactions with pollutants and photons are key factors that affect the applications of TiO 2 in environmental remediation. In this study, the solubilizing agents dimethylsulfoxide and polyoxyethylene sorbitan monooleate, which act as photon competitors, had no effect on the photocatalytic activity of TiO 2 -C-Ag film in phenanthrene (PHE) removal. Fiberglass with TiO 2 -C-Ag coating removed 91.1 ± 5.2 and 99.7 ± 0.4% of PHE in treatments using UVA (365-465 nm) and UVC (254 nm) irradiation, respectively. The use of fiberglass as a support increased the superficial area, thus allowing PHE sorption. C and Ag, which are electrically active impurities in TiO 2 , enhanced its photocatalytic activity and thus the attraction of the pollutant to its surface. The use of high-frequency UV light (UVC) decreased the amount of carbon species deposited on the TiO 2 CAg film surface. X-ray photoelectron spectroscopy of the TiO 2 -C-Ag film revealed extensive oxidation of the carbon deposited on the film under UVC light and loss of electrons from Ag clusters by conversion of Ag 0 to Ag 3+ .

  11. The Intra Uterine Morcellator: a new hysteroscopic operating technique to remove intrauterine polyps and myomas.

    PubMed

    Emanuel, Mark Hans; Wamsteker, Kees

    2005-01-01

    A new hysteroscopic operating technique was compared retrospectively with conventional resectoscopy. Retrospective comparison (Canadian Task Force Classification II-2). Gynecology department of a university-affiliated teaching hospital. Fifty-five women, 27 with endometrial polyps and 28 with submucous myomas. Patients were treated with a prototype of the Intra Uterine Morcellator (IUM). This cutting device, 35 cm in length, was inserted into a straight working channel of a 90-mm hysteroscope. The major advantages were ease of removal of tissue fragments through the instrument and the use of saline solution instead of electrolyte-free solutions used in monopolar high-frequency resectoscopy. The mean operating time was 8.7 minutes (95% CI: 7.3-10.1) for the removal of endometrial polyps compared with 30.9 minutes (CI: 27.0-34.8) for resectoscopy, and 16.4 minutes (CI: 12.6-20.2) for submucous myomas compared with 42.2 minutes (CI: 39.7-44.7) for resectoscopy. All procedures were uneventful. This new technique is faster, and it appears to be easier to perform. Therefore, it can be expected to result in fewer fluid-related complications and to lead to a shorter learning curve when compared with conventional resectoscopy.

  12. A low-cost through-the-wall FMCW radar for stand-off operation and activity detection

    NASA Astrophysics Data System (ADS)

    Chetty, Kevin; Chen, Qingchao; Ritchie, Matthew; Woodbridge, Karl

    2017-05-01

    In this paper we present a new through-wall (TW) FMCW radar system. The architecture of the radar enables both high sensitivity and range resolutions of <1.5 m. Moreover, the radar employs moving target indication (MTI) signal processing to remove the problematic primary wall reflection, allowing higher signal-to- noise and signal-to-interference ratios, which can be traded-off for increased operational stand-off. The TW radar operates at 5.8 GHz with a 200 MHz bandwidth. Its dual-frequency design minimises interference from signal leakage, and permits a baseband output after deramping which is digitized using an inexpensive 24-bit off-the-shelf sound card. The system is therefore an order of magnitude lower in cost than competitor ultrawideband (UWB) TW systems. The high sensitivity afforded by this wide dynamic range has allowed us to develop a wall removal technique whereby high-order digital filters provide a flexible means of MTI filtering based on the phases of the returned echoes. Experimental data demonstrates through-wall detection of individuals and groups of people in various scenarios. Target positions were located to within +/-1.25 m in range, allowing us distinguish between two closely separated targets. Furthermore, at 8.5 m standoff, our wall removal technique can recover target responses that would have otherwise been masked by the primary wall reflection, thus increasing the stand-off capability of the radar. Using phase processing, our experimental data also reveals a clear difference in the micro-Doppler signatures across various types of everyday actions

  13. Long-term outcome of anti-glomerular basement membrane antibody disease treated with immunoadsorption.

    PubMed

    Biesenbach, Peter; Kain, Renate; Derfler, Kurt; Perkmann, Thomas; Soleiman, Afschin; Benharkou, Alexandra; Druml, Wilfred; Rees, Andrew; Säemann, Marcus D

    2014-01-01

    Anti-glomerular basement membrane (GBM) antibody disease may lead to acute crescentic glomerulonephritis with poor renal prognosis. Current therapy favours plasma exchange (PE) for removal of pathogenic antibodies. Immunoadsorption (IAS) is superior to PE regarding efficiency of antibody-removal and safety. Apart from anecdotal data, there is no systemic analysis of the long-term effects of IAS on anti-GBM-disease and antibody kinetics. To examine the long-term effect of high-frequency IAS combined with standard immunosuppression on patient and renal survival in patients with anti-GBM-disease and to quantify antibody removal and kinetics through IAS. Retrospective review of patients treated with IAS for anti-GBM-antibody disease confirmed by biopsy and/or anti-GBM-antibodies. University Hospital of Vienna, Austria. 10 patients with anti-GBM-disease treated with IAS. Patient and renal survival, renal histology, anti-GBM-antibodies. Anti-GBM-antibodies were reduced by the first 9 IAS treatments (mean number of 23) to negative levels in all patients. Renal survival was 40% at diagnosis, 70% after the end of IAS, 63% after one year and 50% at the end of observation (mean 84 months, range 9 to 186). Dialysis dependency was successfully reversed in three of six patients. Patient survival was 90% at the end of observation. IAS efficiently eliminates anti-GBM-antibodies suggesting non-inferiority to PE with regard to renal and patient survival. Hence IAS should be considered as a valuable treatment option for anti-GBM-disease, especially in patients presenting with a high percentage of crescents and dialysis dependency due to an unusual high proportion of responders.

  14. [Quantifying dialysis efficiency for middle molecules in haemodialysis and in convective and mixed techniques].

    PubMed

    Casino, F G; Lopez, T

    2008-01-01

    In contrast to the negative results of the primary analysis, secondary analyses of the HEMO study do support the clinical importance of middle molecule removal. This is in agreement with the findings of large observational studies showing an improvement in mortality and morbidity in dialysis patients treated with high-flux hemodialysis or convective techniques as compared to low-flux hemodialysis. For practical assessment of middle molecule removal, we suggest using the Kt/V of beta2-microglobulin (Kt/Vbeta2-m) with a reference (adequate) value of >or=0.66, which was the average value for the high-flux arm in the HEMO study. For patients on low-flux hemodialysis, where Kt/Vbeta2-m cannot reliably be assessed, we suggest using the Kt/V of vitamin B12 (Kt/VB12), with a reference (adequate) value of >or=0.74, adapted from the findings of the Case Mix Adequacy Study (AJKD 1999). To simplify the routine assessment of these indices, two nomograms are introduced: the first allows to estimate Kt/Vbeta2-m from the post- to pre-dialysis beta2-microglobulin concentration ratio, the second allows to estimate the diffusion dialysis clearance of vitamin B12 from the in vitro dialyzer KoAB12 and actual plasma water flow rate. While waiting for specific trials addressing the issue of dialysis adequacy related to middle molecule removal, clinical experience with the middle molecule indices could provide further quantitative tools for dialysis prescription and favor an increase in dialysis time (or frequency) and/or the use of high-flux hemodialysis and convective techniques.

  15. Radio Frequency Interference Detection and Mitigation Techniques Using Data from Ecosar 2014 Flight Campaign

    NASA Technical Reports Server (NTRS)

    Osmanoglu, Batuhan; Rincon, Rafael F.; Lee, SeungKuk; Fatoyinb, Temilola; Bollian, Tobias

    2016-01-01

    Radio frequency interference (RFI) has strong influence on wide band airborne radar systems, especially operaingat L-band (1-2 GHz) or lower frequencies. EcoSAR is a P-band digital beamforming radar system, and RFI has tobe removed from raw echoes to obtain science quality data. In this paper we describe the current methodologyused to tackle RFI with EcoSAR, and provide an example on its performance. Finally, we discuss the advantagesand disadvantages of the method and mention potential improvements.

  16. Regulation of muscle stiffness during periodic length changes in the isolated abdomen of the hermit crab.

    PubMed

    Chapple, W D

    1997-09-01

    Reflex activation of the ventral superficial muscles (VSM) in the abdomen of the hermit crab, Pagurus pollicarus, was studied using sinusoidal and stochastic longitudinal vibration of the muscle while recording the length and force of the muscle and the spike times of three exciter motoneurons. In the absence of vibration, the interspike interval histograms of the two larger motoneurons were bimodal; cutting sensory nerves containing most of the mechanoreceptor input removed the short interval peak in the histogram, indicating that the receptors are important in maintaining tonic firing. Vibration of the muscle evoked a reflex increase in motoneuron frequency that habituated after an initial peak but remained above control levels for the duration of stimulation. Motoneuron frequency increased with root mean square (rms) stimulus amplitude. Average stiffness during stimulation was about two times the stiffness of passive muscle. The reflex did not alter muscle dynamics. Estimated transfer functions were calculated from the fast Fourier transform of length and force signals. Coherence was >0.9 for the frequency range of 3-35 Hz. Stiffness magnitude gradually increased over this range in both reflex activated and passive muscle; phase was between 10 and 20 degrees. Reflex stiffness decreased with increasing stimulus amplitudes, but at larger amplitudes, this decrease was much less pronounced; in this range stiffness was regulated by the reflex. The sinusoidal frequency at which reflex bursts were elicited was approximately 6 Hz, consistent with previous measurements using ramp stretch. During reflex excitation, there was an increase in amplitude of the short interval peak in the interspike interval histogram; this was reduced when the majority of afferent pathways was removed. A phase histogram of motoneuron firing during sinusoidal vibration had a peak at approximately 110 ms, also suggesting that an important component of the reflex is via direct projections from the mechanoreceptors. These results are consistent with the hypothesis that a robust feedforward regulation of abdominal stiffness during continuous disturbances is achieved by mechanoreceptors signalling the absolute value of changing forces; habituation of the reflex, its high-threshold for low frequency disturbances and the activation kinetics of the muscle further modify reflex dynamics.

  17. Isolating gait-related movement artifacts in electroencephalography during human walking

    PubMed Central

    Kline, Julia E.; Huang, Helen J.; Snyder, Kristine L.; Ferris, Daniel P.

    2016-01-01

    Objective High-density electroencephelography (EEG) can provide insight into human brain function during real-world activities with walking. Some recent studies have used EEG to characterize brain activity during walking, but the relative contributions of movement artifact and electrocortical activity have been difficult to quantify. We aimed to characterize movement artifact recorded by EEG electrodes at a range of walking speeds and to test the efficacy of artifact removal methods. We also quantified the similarity between movement artifact recorded by EEG electrodes and a head-mounted accelerometer. Approach We used a novel experimental method to isolate and record movement artifact with EEG electrodes during walking. We blocked electrophysiological signals using a nonconductive layer (silicone swim cap) and simulated an electrically conductive scalp on top of the swim cap using a wig coated with conductive gel. We recorded motion artifact EEG data from nine young human subjects walking on a treadmill at speeds from 0.4–1.6 m/s. We then tested artifact removal methods including moving average and wavelet-based techniques. Main Results Movement artifact recorded with EEG electrodes varied considerably, across speed, subject, and electrode location. The movement artifact measured with EEG electrodes did not correlate well with head acceleration. All of the tested artifact removal methods attenuated low-frequency noise but did not completely remove movement artifact. The spectral power fluctuations in the movement artifact data resembled data from some previously published studies of EEG during walking. Significance Our results suggest that EEG data recorded during walking likely contains substantial movement artifact that: cannot be explained by head accelerations; varies across speed, subject, and channel; and cannot be removed using traditional signal processing methods. Future studies should focus on more sophisticated methods for removing of EEG movement artifact to advance the field. PMID:26083595

  18. Isolating gait-related movement artifacts in electroencephalography during human walking.

    PubMed

    Kline, Julia E; Huang, Helen J; Snyder, Kristine L; Ferris, Daniel P

    2015-08-01

    High-density electroencephelography (EEG) can provide an insight into human brain function during real-world activities with walking. Some recent studies have used EEG to characterize brain activity during walking, but the relative contributions of movement artifact and electrocortical activity have been difficult to quantify. We aimed to characterize movement artifact recorded by EEG electrodes at a range of walking speeds and to test the efficacy of artifact removal methods. We also quantified the similarity between movement artifact recorded by EEG electrodes and a head-mounted accelerometer. We used a novel experimental method to isolate and record movement artifact with EEG electrodes during walking. We blocked electrophysiological signals using a nonconductive layer (silicone swim cap) and simulated an electrically conductive scalp on top of the swim cap using a wig coated with conductive gel. We recorded motion artifact EEG data from nine young human subjects walking on a treadmill at speeds from 0.4 to 1.6 m s(-1). We then tested artifact removal methods including moving average and wavelet-based techniques. Movement artifact recorded with EEG electrodes varied considerably, across speed, subject, and electrode location. The movement artifact measured with EEG electrodes did not correlate well with head acceleration. All of the tested artifact removal methods attenuated low-frequency noise but did not completely remove movement artifact. The spectral power fluctuations in the movement artifact data resembled data from some previously published studies of EEG during walking. Our results suggest that EEG data recorded during walking likely contains substantial movement artifact that: cannot be explained by head accelerations; varies across speed, subject, and channel; and cannot be removed using traditional signal processing methods. Future studies should focus on more sophisticated methods for removal of EEG movement artifact to advance the field.

  19. A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Hui, E-mail: corinna@seu.edu.cn; Key Laboratory of Computer Network and Information Integration; Centre de Recherche en Information Biomédicale sino-français, Laboratoire International Associé, Inserm, Université de Rennes 1, Rennes 35000

    2015-04-15

    Purpose: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information. Methods: The method is as follows. The input image is first recursively decomposed into several smaller subimagesmore » using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform. Results: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high. Conclusions: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time.« less

  20. Decontamination of blood soaked electronic devices using ultrasonic technology.

    PubMed

    Dudeck, Kimberly C; Brennan, Tamara C; Embury, Daniel J

    2012-01-10

    With advancements in technology allowing for the miniaturization of consumer electronics, criminal investigations of all types frequently involve the forensic examination of electronic devices, such as cellular telephones, smartphones, and portable flash memory; in some extreme, violent cases, these devices are found covered in blood. Due to the complexity of such devices, standard operating procedures for the complete removal of blood had not previously been established by the Royal Canadian Mounted Police prior to this study. The electronics industry has adopted the use of the ultrasonic cleaner for sanitizing printed circuit boards (PCBs) by removing residues and contaminants. High frequency sound waves created by the machine penetrate and remove dirt and residues; however, early research during the 1950s recorded these sound waves breaking the internal bonds of integrated circuit chips. Experimentation with modern ultrasonic technology was used to determine if internal components were damaged, as well as if ultrasonic cleaning was the most suitable method for the removal of dried and liquid blood from a PCB. Several disinfectant solutions were compared against the 0.5% Triton(®) X-100 detergent solution in the ultrasonic cleaner, including: 10% sodium hypochlorite bleach, 85% isopropyl alcohol, and Conflikt(®) disinfectant spray. The results not only demonstrated that the ultrasonic cleaner did not damage the vital memory chip on the PCB, but also, with the assistance of Conflikt(®), was able to remove all traces of blood as indicated by Hemastix(®) reagent strips. Of five methods experimented with, two cycles of ultrasonic cleaning followed by sanitization with Conflikt(®) proved to be the only procedure capable of removing all traces of blood, as confirmed with both Hemastix(®) reagent strips and the hemochromogen test. Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Ultrastable laser array at 633 nm for real-time dimensional metrology

    NASA Astrophysics Data System (ADS)

    Lawall, John; Pedulla, J. Marc; Le Coq, Yann

    2001-07-01

    We describe a laser system for very-high-accuracy dimensional metrology. A sealed-cavity helium-neon laser is offset locked to an iodine-stabilized laser in order to realize a secondary standard with higher power and less phase noise. Synchronous averaging is employed to remove the effect of the frequency modulation present on the iodine-stabilized laser. Additional lasers are offset locked to the secondary standard for use in interferometry. All servo loops are implemented digitally. The offset-locked lasers have intrinsic linewidths of the order of 2.5 kHz and exhibit a rms deviation from the iodine-stabilized laser below 18 kHz. The amplitude noise is at the shot-noise limit for frequencies above 700 kHz. We describe and evaluate the system in detail, and include a discussion of the noise associated with various types of power supplies.

  2. Parameter Estimation for GRACE-FO Geometric Ranging Errors

    NASA Astrophysics Data System (ADS)

    Wegener, H.; Mueller, V.; Darbeheshti, N.; Naeimi, M.; Heinzel, G.

    2017-12-01

    Onboard GRACE-FO, the novel Laser Ranging Instrument (LRI) serves as a technology demonstrator, but it is a fully functional instrument to provide an additional high-precision measurement of the primary mission observable: the biased range between the two spacecraft. Its (expectedly) two largest error sources are laser frequency noise and tilt-to-length (TTL) coupling. While not much can be done about laser frequency noise, the mechanics of the TTL error are widely understood. They depend, however, on unknown parameters. In order to improve the quality of the ranging data, it is hence essential to accurately estimate these parameters and remove the resulting TTL error from the data.Means to do so will be discussed. In particular, the possibility of using calibration maneuvers, the utility of the attitude information provided by the LRI via Differential Wavefront Sensing (DWS), and the benefit from combining ranging data from LRI with ranging data from the established microwave ranging, will be mentioned.

  3. Bi-directional four quadrant (BDQ4) power converter development

    NASA Technical Reports Server (NTRS)

    Schwarz, F. C.

    1979-01-01

    The feasibility for implementation of a concept for direct ac/dc multikilowatt power conversion with bidirectional transfer of energy was investigated. A 10 kHz current carrier was derived directly from a common 60 Hz three phase power system. This carrier was modulated to remove the 360 Hz ripple, inherent in the three phase power supply and then demodulated and processed by a high frequency filter. The resulting dc power was then supplied to a load. The process was implemented without the use of low frequency transformers and filters. This power conversion processes was reversible and can operate in the four quadrants as viewed from any of the two of the converter's ports. Areas of application include: power systems on air and spacecraft; terrestrial traction; integration of solar and wind powered systems with utility networks; HVDC; asynchronous coupling of polyphase networks; heat treatment; industrial machine drives; and power supplies for any use including instrumentation.

  4. Design, fabrication, and testing of the BNL radio frequency quadrupole accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, H.; Clifford, T.; Giordano, S.

    1984-01-01

    The Brookhaven National Laboratory polarized H/sup -/ injection program for the AGS utilizes a Radio Frequency Quadrupole Accelerator for acceleration between the polarized source and the Alvarez Linac. Although operation has commenced with a few ..mu.. amperes of H/sup -/ beam, it is anticipated that future polarized H/sup -/ sources will have a considerably improved output. The RFQ will operate at 201.25 MHz and will be capable of handling a beam current of 0.02 amperes with a duty cycle of 0.25%. The resulting low average power has allowed novel solutions to the problems of vane alignment, rf current contacts, andmore » removal of heat from the vanes. The design philosophy, details of cavity fabrication, and vane machining will be discussed. Results of low and high power rf testing will be presented together with the initial results of operations in the polarized H/sup -/ beam line.« less

  5. Methods for improved forewarning of critical events across multiple data channels

    DOEpatents

    Hively, Lee M [Philadelphia, TN

    2007-04-24

    This disclosed invention concerns improvements in forewarning of critical events via phase-space dissimilarity analysis of data from mechanical devices, electrical devices, biomedical data, and other physical processes. First, a single channel of process-indicative data is selected that can be used in place of multiple data channels without sacrificing consistent forewarning of critical events. Second, the method discards data of inadequate quality via statistical analysis of the raw data, because the analysis of poor quality data always yields inferior results. Third, two separate filtering operations are used in sequence to remove both high-frequency and low-frequency artifacts using a zero-phase quadratic filter. Fourth, the method constructs phase-space dissimilarity measures (PSDM) by combining of multi-channel time-serial data into a multi-channel time-delay phase-space reconstruction. Fifth, the method uses a composite measure of dissimilarity (C.sub.i) to provide a forewarning of failure and an indicator of failure onset.

  6. Wideband Scattering Diffusion by using Diffraction of Periodic Surfaces and Optimized Unit Cell Geometries

    PubMed Central

    Costa, Filippo; Monorchio, Agostino; Manara, Giuliano

    2016-01-01

    A methodology to obtain wideband scattering diffusion based on periodic artificial surfaces is presented. The proposed surfaces provide scattering towards multiple propagation directions across an extremely wide frequency band. They comprise unit cells with an optimized geometry and arranged in a periodic lattice characterized by a repetition period larger than one wavelength which induces the excitation of multiple Floquet harmonics. The geometry of the elementary unit cell is optimized in order to minimize the reflection coefficient of the fundamental Floquet harmonic over a wide frequency band. The optimization of FSS geometry is performed through a genetic algorithm in conjunction with periodic Method of Moments. The design method is verified through full-wave simulations and measurements. The proposed solution guarantees very good performance in terms of bandwidth-thickness ratio and removes the need of a high-resolution printing process. PMID:27181841

  7. Role of high-order aberrations in senescent changes in spatial vision

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliot, S; Choi, S S; Doble, N

    2009-01-06

    The contributions of optical and neural factors to age-related losses in spatial vision are not fully understood. We used closed-loop adaptive optics to test the visual benefit of correcting monochromatic high-order aberrations (HOAs) on spatial vision for observers ranging in age from 18-81 years. Contrast sensitivity was measured monocularly using a two-alternative forced choice (2AFC) procedure for sinusoidal gratings over 6 mm and 3 mm pupil diameters. Visual acuity was measured using a spatial 4AFC procedure. Over a 6 mm pupil, young observers showed a large benefit of AO at high spatial frequencies, whereas older observers exhibited the greatest benefitmore » at middle spatial frequencies, plus a significantly larger increase in visual acuity. When age-related miosis is controlled, young and old observers exhibited a similar benefit of AO for spatial vision. An increase in HOAs cannot account for the complete senescent decline in spatial vision. These results may indicate a larger role of additional optical factors when the impact of HOAs is removed, but also lend support for the importance of neural factors in age-related changes in spatial vision.« less

  8. Accelerated simulations of aromatic polymers: application to polyether ether ketone (PEEK)

    NASA Astrophysics Data System (ADS)

    Broadbent, Richard J.; Spencer, James S.; Mostofi, Arash A.; Sutton, Adrian P.

    2014-10-01

    For aromatic polymers, the out-of-plane oscillations of aromatic groups limit the maximum accessible time step in a molecular dynamics simulation. We present a systematic approach to removing such high-frequency oscillations from planar groups along aromatic polymer backbones, while preserving the dynamical properties of the system. We consider, as an example, the industrially important polymer, polyether ether ketone (PEEK), and show that this coarse graining technique maintains excellent agreement with the fully flexible all-atom and all-atom rigid bond models whilst allowing the time step to increase fivefold to 5 fs.

  9. Eddy Current Testing with Giant Magnetoresistance (GMR) Sensors and a Pipe-Encircling Excitation for Evaluation of Corrosion under Insulation

    PubMed Central

    Bailey, Joseph; Hunze, Arvid

    2017-01-01

    This work investigates an eddy current-based non-destructive testing (NDT) method to characterize corrosion of pipes under thermal insulation, one of the leading failure mechanisms for insulated pipe infrastructure. Artificial defects were machined into the pipe surface to simulate the effect of corrosion wall loss. We show that by using a giant magnetoresistance (GMR) sensor array and a high current (300 A), single sinusoidal low frequency (5–200 Hz) pipe-encircling excitation scheme it is possible to quantify wall loss defects without removing the insulation or weather shield. An analysis of the magnetic field distribution and induced currents was undertaken using the finite element method (FEM) and analytical calculations. Simple algorithms to remove spurious measured field variations not associated with defects were developed and applied. The influence of an aluminium weather shield with discontinuities and dents was ascertained and found to be small for excitation frequency values below 40 Hz. The signal dependence on the defect dimensions was analysed in detail. The excitation frequency at which the maximum field amplitude change occurred increased linearly with the depth of the defect by about 3 Hz/mm defect depth. The change in magnetic field amplitude due to defects for sensors aligned in the azimuthal and radial directions were measured and found to be linearly dependent on the defect volume between 4400–30,800 mm3 with 1.2 × 10−3−1.6 × 10−3 µT/mm3. The results show that our approach is well suited for measuring wall loss defects similar to the defects from corrosion under insulation. PMID:28956855

  10. Eddy Current Testing with Giant Magnetoresistance (GMR) Sensors and a Pipe-Encircling Excitation for Evaluation of Corrosion under Insulation.

    PubMed

    Bailey, Joseph; Long, Nicholas; Hunze, Arvid

    2017-09-28

    This work investigates an eddy current-based non-destructive testing (NDT) method to characterize corrosion of pipes under thermal insulation, one of the leading failure mechanisms for insulated pipe infrastructure. Artificial defects were machined into the pipe surface to simulate the effect of corrosion wall loss. We show that by using a giant magnetoresistance (GMR) sensor array and a high current (300 A), single sinusoidal low frequency (5-200 Hz) pipe-encircling excitation scheme it is possible to quantify wall loss defects without removing the insulation or weather shield. An analysis of the magnetic field distribution and induced currents was undertaken using the finite element method (FEM) and analytical calculations. Simple algorithms to remove spurious measured field variations not associated with defects were developed and applied. The influence of an aluminium weather shield with discontinuities and dents was ascertained and found to be small for excitation frequency values below 40 Hz. The signal dependence on the defect dimensions was analysed in detail. The excitation frequency at which the maximum field amplitude change occurred increased linearly with the depth of the defect by about 3 Hz/mm defect depth. The change in magnetic field amplitude due to defects for sensors aligned in the azimuthal and radial directions were measured and found to be linearly dependent on the defect volume between 4400-30,800 mm³ with 1.2 × 10 -3 -1.6 × 10 -3 µT/mm³. The results show that our approach is well suited for measuring wall loss defects similar to the defects from corrosion under insulation.

  11. Multi-scale responses of vegetation to removal of horse grazing from Great Basin (USA) mountain ranges

    USGS Publications Warehouse

    Beever, E.A.; Tausch, R.J.; Thogmartin, W.E.

    2008-01-01

    Although free-roaming equids occur on all of the world's continents except Antarctica, very few studies (and none in the Great Basin, USA) have either investigated their grazing effects on vegetation at more than one spatial scale or compared characteristics of areas from which grazing has been removed to those of currently grazed areas. We compared characteristics of vegetation at 19 sites in nine mountain ranges of the western Great Basin; sites were either grazed by feral horses (Equus caballus) or had had horses removed for the last 10-14 years. We selected horse-occupied and horse-removed sites with similar aspect, slope, fire history, grazing pressure by cattle (minimal to none), and dominant vegetation (Artemisia tridentata). During 1997 and 1998, line-intercept transects randomly located within sites revealed that horse-removed sites exhibited 1.1-1.9 times greater shrub cover, 1.2-1.5 times greater total plant cover, 2-12 species greater plant species richness, and 1.9-2.9 times greater cover and 1.1-2.4 times greater frequency of native grasses than did horse-occupied sites. In contrast, sites with horses tended to have more grazing-resistant forbs and exotic plants. Direction and magnitude of landscape-scale results were corroborated by smaller-scale comparisons within horse-occupied sites of horse-trail transects and (randomly located) transects that characterized overall site conditions. Information-theoretic analyses that incorporated various subsets of abiotic variables suggested that presence of horses was generally a strong determinant of those vegetation-related variables that differed significantly between treatments, especially frequency and cover of grasses, but also species richness and shrub cover and frequency. In contrast, abiotic variables such as precipitation, site elevation, and soil erodibility best predicted characteristics such as forb cover, shrub frequency, and continuity of the shrub canopy. We found species richness of plants monotonically decreased across sites as grazing disturbance increased, suggesting that either the bell-shaped diversity-disturbance curve of the intermediate-disturbance hypothesis does not apply in this system or that most sites are already all on the greater-disturbance slope of the curve. In our study, numerous vegetation properties of less-grazed areas and sites differed notably from horse-grazed sites at local and landscape scales during a wetter and an average-precipitation year. ?? 2007 Springer Science+Business Media B.V.

  12. EDDIE Seismology: Introductory spectral analysis for undergraduates

    NASA Astrophysics Data System (ADS)

    Soule, D. C.; Gougis, R.; O'Reilly, C.

    2016-12-01

    We present a spectral seismology lesson in which students use spectral analysis to describe the frequency of seismic arrivals based on a conceptual presentation of waveforms and filters. The goal is for students to surpass basic waveform terminology and relate a time domain signals to their conjugates in the frequency domain. Although seismology instruction commonly engages students in analysis of authentic seismological data, this is less true for lower-level undergraduate seismology instruction due to coding barriers to many seismological analysis tasks. To address this, our module uses Seismic Canvas (Kroeger, 2015; https://seiscode.iris.washington.edu/projects/seismiccanvas), a graphically interactive application for accessing, viewing and analyzing waveform data, which we use to plot earthquake data in the time domain. Once students are familiarized with the general components of the waveform (i.e. frequency, wavelength, amplitude and period), they use Seismic Canvas to transform the data into the frequency domain. Bypassing the mathematics of Fourier Series allows focus on conceptual understanding by plotting and manipulating seismic data in both time and frequency domains. Pre/post-tests showed significant improvements in students' use of seismograms and spectrograms to estimate the frequency content of the primary wave, which demonstrated students' understanding of frequency and how data on the spectrogram and seismogram are related. Students were also able to identify the time and frequency of the largest amplitude arrival, indicating understanding of amplitude and use of a spectrogram as an analysis tool. Students were also asked to compare plots of raw data and the same data filtered with a high-pass filter, and identify the filter used to create the second plot. Students demonstrated an improved understanding of how frequency content can be removed from a signal in the spectral domain.

  13. Low Frequency Vibration approach to asess the Performance of wood structural Systems

    Treesearch

    Xiping Wang; Robert J. Ross; Michael O. Hunt

    2004-01-01

    The primary means of inspecting buildings and other structures is to evaluate each structure member individually. This is a time consuming process that is expensive, particularly if sheathing or other covering materials must be removed to access the structural members. This paper presents an effort to use a low frequency vibration method for assessing the structural...

  14. Low frequency vibration approach for assessing performance of wood floor systems

    Treesearch

    Xiping Wang; Robert J. Ross; Michael O. Hunt; John R. Erickson; John W. Forsman

    2005-01-01

    The primary means of inspecting buildings and other structures is to evaluate each structure member individually. This is a time-consuming and expensive process, particularly if sheathing or other covering materials must be removed to access the structural members. The objective of this study was to determine if a low frequency vibration method could be used to...

  15. The ability of exogenous growth hormone to maintain milk production during prolonged lactation in the mouse is more evident with reduced nursing frequency

    USDA-ARS?s Scientific Manuscript database

    Although growth hormone (GH) increases milk production in dairy animals, the milk production response of lactating rodents to this treatment has been variable. Milk removal frequency in the lactating mouse is about 10-fold higher than that of lactating dairy cows. The hypothesis tested in this study...

  16. Pressurized rf cavities in ionizing beams

    DOE PAGES

    Freemire, B.; Tollestrup, A.  V.; Yonehara, K.; ...

    2016-06-20

    A muon collider or Higgs factory requires significant reduction of the six dimensional emittance of the beam prior to acceleration. One method to accomplish this involves building a cooling channel using high pressure gas filled radio frequency cavities. The performance of such a cavity when subjected to an intense particle beam must be investigated before this technology can be validated. To this end, a high pressure gas filled radio frequency (rf) test cell was built and placed in a 400 MeV beam line from the Fermilab linac to study the plasma evolution and its effect on the cavity. Hydrogen, deuterium, helium and nitrogen gases were studied. Additionally, sulfur hexafluoride and dry air were used as dopants to aid in the removal of plasma electrons. Measurements were made using a variety of beam intensities, gas pressures, dopant concentrations, and cavity rf electric fields, both with and without a 3 T external solenoidal magnetic field. In conclusion, energy dissipation per electron-ion pair, electron-ion recombination rates, ion-ion recombination rates, and electron attachment times to SFmore » $$_6$$ and O$$_2$$ were measured.« less

  17. Small fenestra stapedectomy. A preliminary report.

    PubMed

    Bailey, H A; Pappas, J J; Graham, S S

    1981-08-01

    The small fenestra stapedectomy is based on a rationale of creating a more effective acoustical mechanical transmission system, while reducing potential labyrinthine disturbance. Surgical technique for the small fenestra stapedectomy is described, including the creation of the fenestra and the use of McGee stainless steel piston prosthesis with loose areolar tissue around the piston. Postoperative results are compared in a series of 100 cases, 50 having the small fenestra technique, SFT, and 50 having partial or total footplate removal procedure. Vestibular results demonstrate a noticeable reduction in postoperative complaints of balance disorders in the SFT patients. Hearing results, when compared between the two groups, show a statistically significant advantage for the SFT patients in postoperative high frequency threshold sensitivity and speech discrimination scores. Technical difficulties in creating the fenestra without fracturing the entire footplate are discussed and suggestions made for their avoidance. The advantages of lowered risk, based on reduced trauma to and contamination of the labyrinth, as well as improved high frequency hearing sensitivity and speech discrimination, support the use of this procedure and call for further investigation and development of its clinical potential.

  18. EFFECTIVE REMOVAL METHOD OF ILLEGAL PARKING BICYCLES BASED ON THE QUANTITATIVE CHANGE AFTER REMOVAL

    NASA Astrophysics Data System (ADS)

    Toi, Satoshi; Kajita, Yoshitaka; Nishikawa, Shuichirou

    This study aims to find an effective removal method of illegal parking bicycles based on the analysis on the numerical change of illegal bicycles. And then, we built the time and space quantitative distribution model of illegal parking bicycles after removal, considering the logistic increase of illegal parking bicycles, several behaviors concerning of direct return or indirect return to the original parking place and avoidance of the original parking place, based on the investigation of real condition of illegal bicycle parking at TENJIN area in FUKUOKA city. Moreover, we built the simulation model including above-mentioned model, and calculated the number of illegal parking bicycles when we change the removal frequency and the number of removal at one time. The next interesting four results were obtained. (1) Recovery speed from removal the illegal parking bicycles differs by each zone. (2) Thorough removal is effective to keep the number of illegal parking bicycles lower level. (3) Removal at one zone causes the increase of bicycles at other zones where the level of illegal parking is lower. (4) The relationship between effects and costs of removing the illegal parking bicycles was clarified.

  19. Effects of coarse woody debris and its removal on a channel affected by the 1980 eruption of Mount St. Helens, Washington

    Treesearch

    Thomas E. Lisle

    1995-01-01

    Abstract - During the May 18, 1980, eruption of Mount St. Helens, Washington, a pyroclastic surge introduced large volumes of coarse woody debris (CWD) and fine grained sediment to Clearwater Creek, approximately 15 km northeast of the summit. Effects of controlled CWD removal on sediment storage, substrate, and pool frequency and volume were measured in four reaches,...

  20. Resonant scattering of energetic electrons in the plasmasphere by monotonic whistler-mode waves artificially generated by ionospheric modification

    NASA Astrophysics Data System (ADS)

    Chang, S. S.; Ni, B. B.; Bortnik, J.; Zhou, C.; Zhao, Z. Y.; Li, J. X.; Gu, X. D.

    2014-05-01

    Modulated high-frequency (HF) heating of the ionosphere provides a feasible means of artificially generating extremely low-frequency (ELF)/very low-frequency (VLF) whistler waves, which can leak into the inner magnetosphere and contribute to resonant interactions with high-energy electrons in the plasmasphere. By ray tracing the magnetospheric propagation of ELF/VLF emissions artificially generated at low-invariant latitudes, we evaluate the relativistic electron resonant energies along the ray paths and show that propagating artificial ELF/VLF waves can resonate with electrons from ~ 100 keV to ~ 10 MeV. We further implement test particle simulations to investigate the effects of resonant scattering of energetic electrons due to triggered monotonic/single-frequency ELF/VLF waves. The results indicate that within the period of a resonance timescale, changes in electron pitch angle and kinetic energy are stochastic, and the overall effect is cumulative, that is, the changes averaged over all test electrons increase monotonically with time. The localized rates of wave-induced pitch-angle scattering and momentum diffusion in the plasmasphere are analyzed in detail for artificially generated ELF/VLF whistlers with an observable in situ amplitude of ~ 10 pT. While the local momentum diffusion of relativistic electrons is small, with a rate of < 10-7 s-1, the local pitch-angle scattering can be intense near the loss cone with a rate of ~ 10-4 s-1. Our investigation further supports the feasibility of artificial triggering of ELF/VLF whistler waves for removal of high-energy electrons at lower L shells within the plasmasphere. Moreover, our test particle simulation results show quantitatively good agreement with quasi-linear diffusion coefficients, confirming the applicability of both methods to evaluate the resonant diffusion effect of artificial generated ELF/VLF whistlers.

  1. [Cough induction by high-frequency chest percussion in healthy volunteers and patients with common cold].

    PubMed

    Lee, P C L; Eccles, R

    2004-08-01

    In patients with chronic obstructive pulmonary disease, chest percussion is often used to facilitate the drainage of respiratory secretions which may be removed from the airway by coughing. The cough reflex is believed to be mediated by mechanically sensitive rapidly adapting receptors (RARs). Chest percussion stimulation may stimulate RAR cough receptors, but there is no evidence that mechanical airway stimulation in man induces cough. The aim of this study was to determine if cough can be induced by high-frequency chest percussion in healthy subjects and in patients with acute upper respiratory tract infection (URTI). Two groups were studied: 15 healthy subjects and 29 subjects with URTI, mean age 22 years. Percussion stimulation (70 Hz) was applied to the chest. Cough frequency and latency were recorded. All subjects were asked to complete a questionnaire about how they felt after the chest percussion by questionnaires. The results demonstrate that high-frequency chest percussion causes cough in human subjects with a recent history of URTI, but induces relatively little cough in healthy subjects. In URTI subjects there was a significant increase in the number of coughs after three periods of airway vibration, whereas in healthy subjects there was no change in cough. Furthermore, analysis of the questionnaires showed that more of the subjects with URTI felt an urge to cough compared to the healthy subjects in the subjective questionnaires. This study demonstrates that cough can be induced in subjects with URTI by chest percussion. This method of inducing cough in subjects with URTI may be useful for studies on the mechanism of cough and for studies on antitussive medicines.

  2. Association between occupational exposure to benzene and chromosomal alterations in lymphocytes of Brazilian petrochemical workers removed from exposure.

    PubMed

    Gonçalves, Rozana Oliveira; de Almeida Melo, Neli; Rêgo, Marco Antônio Vasconcelos

    2016-06-01

    We aimed to investigate the association between chronic exposure to benzene and genotoxicity in the lymphocytes of workers removed from exposure. The study included 20 workers with hematological disorders who had previously worked in the petrochemical industry of Salvador, Bahia, Brazil; 16 workers without occupational exposure to benzene served as the control group. Chromosomal analysis was performed on lymphocytes from peripheral blood, to assess chromosomal breaks and gaps and to identify aneuploidy. The Kruskal-Wallis test was used to compare the mean values between two groups, and Student's t test for comparison of two independent means. The frequency of gaps was statistically higher in and the exposed group than in the controls (2.13 ± 2.86 vs. 0.97 ± 1.27, p = 0.001). The frequency of chromosomal breaks was significantly higher among cases (0.21 ± 0.58) than among controls (0.12 ± 0.4) (p = 0.0002). An association was observed between chromosomal gaps and breaks and occupational exposure to benzene. Our study showed that even when removed from exposure for several years, workers still demonstrated genotoxic damage. Studies are still needed to clarify the long-term genotoxic potential of benzene after removal from exposure.

  3. A survey of recommendations on the care of ocular prostheses.

    PubMed

    Osborn, Katherine L; Hettler, Debbie

    2010-03-01

    The purpose of this study was to determine if there is a consistent set of recommendations for patients who wear an ocular prosthesis or if each patient needs an individual plan. A self-report questionnaire was distributed to members of the American Society of Ocularists. The survey consisted of 4 questions regarding frequency of removal and cleaning and preferred cleaning and lubrication agents. Respondents had 4 weeks to return the survey for results to be included. One hundred three surveys were sent; 8 were undeliverable, leaving a sample size of 95. Thirty-four percent (32 ocularists) responded. The reason with the most frequency for prosthesis removal was only when the prosthesis felt irritated (31%). Fifty-eight percent reported that the ocular prosthesis should be cleaned every time it is removed. Mild soap or baby shampoo was listed as the preferred cleaning agent with 24% each. A majority listed a silicone oil-based lubricant (29%), but responses varied based on the patient's needs. An individualized treatment plan is indicated for most patients who wear an ocular prosthesis. Despite this, some commonalities in responses were noted, specifically that the ocular prosthesis needs to be cleaned with every removal, and a silicone oil lubricant is recommended. Copyright (c) 2010 American Optometric Association. All rights reserved.

  4. Technological innovations in tissue removal during rhinologic surgery.

    PubMed

    Sindwani, Raj; Manz, Ryan

    2012-01-01

    The modern rhinologist has a wide variety of technological innovations at his/her disposal for the removal of soft tissue and bone during endoscopic surgery. We identified and critically evaluated four leading tissue removal technologies that have impacted, or are poised to impact, rhinological surgery. A literature review was conducted. Technological functions, strengths and limitations of microdebriders, radio frequency ablation, endoscopic drills, and ultrasonic aspirators were explored. The primary drawback of powered instruments continues to be the higher costs associated with their use, and their main advantage is the ability to accomplish multiple functions such as tissue removal, suction, and irrigation, all with one tool. The effective and safe use of any powered instrument requires an intimate understanding of its function, capabilities, and limitations. Powered instrumentation continues to play a significant and evolving role in soft tissue and bone removal during rhinologic surgery.

  5. Influence of substrate concentration and feed frequency on ammonia inhibition in microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Tice, Ryan C.; Kim, Younggy

    2014-12-01

    Excessive amounts of ammonia are known to inhibit exoelectrogenic activities in microbial fuel cells (MFCs). However, the threshold ammonia concentration that triggers toxic effects is not consistent among literature papers, indicating that ammonia inhibition can be affected by other operational factors. Here, we examined the effect of substrate concentration and feed frequency on the capacity of exoelectrogenic bacteria to resist against ammonia inhibition. The high substrate condition (2 g L-1 sodium acetate, 2-day feed) maintained high electricity generation (between 1.1 and 1.9 W m-2) for total ammonia concentration up to 4000 mg-N L-1. The less frequent feed condition (2 g L-1 sodium acetate, 6-day feed) and the low substrate condition (0.67 g L-1 sodium acetate, 2-day feed) resulted in substantial decreases in electricity generation at total ammonia concentration of 2500 and 3000 mg-N L-1, respectively. It was determined that the power density curve serves as a better indicator than continuously monitored electric current for predicting ammonia inhibition in MFCs. The chemical oxygen demand (COD) removal gradually decreased at high ammonia concentration even without ammonia inhibition in electricity generation. The experimental results demonstrated that high substrate concentration and frequent feed substantially enhance the capacity of exoelectrogenic bacteria to resist against ammonia inhibition.

  6. Reconfigurable microwave photonic in-phase and quadrature detector for frequency agile radar.

    PubMed

    Emami, Hossein; Sarkhosh, Niusha

    2014-06-01

    A microwave photonic in-phase and quadrature detector is conceived and practically demonstrated. The detector has the ability to become electronically reconfigured to operate at any frequency over a wide range. This makes it an excellent candidate for frequency agile radars and other electronic warfare systems based on frequency hopping. The detector exhibits a very low amplitude and phase imbalance, which removes the need for any imbalance compensation technique. The system is designed based on the transversal filtering concept and reconfigurability is achieved via wavelength control in a dispersive fiber. The system operation was demonstrated over a frequency range of 3.5-35 GHz, with a maximum of -32 dB amplitude imbalance.

  7. The Galileo probe Doppler wind experiment: Measurement of the deep zonal winds on Jupiter

    NASA Astrophysics Data System (ADS)

    Atkinson, David H.; Pollack, James B.; Seiff, Alvin

    1998-09-01

    During its descent into the upper atmosphere of Jupiter, the Galileo probe transmitted data to the orbiter for 57.5 min. Accurate measurements of the probe radio frequency, driven by an ultrastable oscillator, allowed an accurate time history of the probe motions to be reconstructed. Removal from the probe radio frequency profile of known Doppler contributions, including the orbiter trajectory, the probe descent velocity, and the rotation of Jupiter, left a measurable frequency residual due to Jupiter's zonal winds, and microdynamical motion of the probe from spin, swing under the parachute, atmospheric turbulence, and aerodynamic buffeting. From the assumption of the dominance of the zonal horizontal winds, the frequency residuals were inverted and resulted in the first in situ measurements of the vertical profile of Jupiter's deep zonal winds. A number of error sources with the capability of corrupting the frequency measurements or the interpretation of the frequency residuals were considered using reasonable assumptions and calibrations from prelaunch and in-flight testing. It is found that beneath the cloud tops (about 700 mbar) the winds are prograde and rise rapidly to 170 m/s at 4 bars. Beyond 4 bars to the depth at which the link with the probe was lost, nearly 21 bars, the winds remain constant and strong. Corrections for the high temperatures encountered by the probe have recently been completed and provide no evidence of diminishing or strengthening of the zonal wind profile in the deeper regions explored by the Galileo probe.

  8. Repeated burning of eastern tallgrass prairie increases richness and diversity, stabilizing late successional vegetation.

    PubMed

    Bowles, Marlin L; Jones, Michael D

    2013-03-01

    Understanding temporal effects of fire frequency on plant species diversity and vegetation structure is critical for managing tallgrass prairie (TGP), which occupies a mid-continental longitudinal precipitation and productivity gradient. Eastern TGP has contributed little information toward understanding whether vegetation-fire interactions are uniform or change across this biome. We resampled 34 fire-managed mid- and late-successional ungrazed TGP remnants occurring across a dry to wet-mesic moisture gradient in the Chicago region of Illinois, USA. We compared hypotheses that burning acts either as a stabilizing force or causes change in diversity and structure, depending upon fire frequency and successional stage. Based on western TGP, we expected a unimodal species richness distribution across a cover-productivity gradient, variable functional group responses to fire frequency, and a negative relationship between fire frequency and species richness. Species diversity was unimodal across the cover gradient and was more strongly humpbacked in stands with greater fire frequency. In support of a stabilizing hypothesis, temporal similarity of late-successional vegetation had a logarithmic relationship with increasing fire frequency, while richness and evenness remained stable. Temporal similarity within mid-successional stands was not correlated with fire frequency, while richness increased and evenness decreased over time. Functional group responses to fire frequency were variable. Summer forb richness increased under high fire frequency, while C4 grasses, spring forbs, and nitrogen-fixing species decreased with fire exclusion. On mesic and wet-mesic sites, vegetation structure measured by the ratio of woody to graminoid species was negatively correlated with abundance of forbs and with fire frequency. Our findings that species richness responds unimodally to an environmental-productivity gradient, and that fire exclusion increases woody vegetation and leads to loss of C4 and N-fixing species, suggest that these processes are uniform across the TGP biome and not affected by its rainfall-productivity gradient. However, increasing fire frequency in eastern TGP appears to increase richness of summer forbs and stabilize late-successional vegetation in the absence of grazing, and these processes may differ across the longitudinal axis of TGP. Managing species diversity in ungrazed eastern TGP may be dependent upon high fire frequency that removes woody vegetation and prevents biomass accumulation.

  9. The acoustical cues to sound location in the Guinea pig (cavia porcellus)

    PubMed Central

    Greene, Nathanial T; Anbuhl, Kelsey L; Williams, Whitney; Tollin, Daniel J.

    2014-01-01

    There are three main acoustical cues to sound location, each attributable to space-and frequency-dependent filtering of the propagating sound waves by the outer ears, head, and torso: Interaural differences in time (ITD) and level (ILD) as well as monaural spectral shape cues. While the guinea pig has been a common model for studying the anatomy, physiology, and behavior of binaural and spatial hearing, extensive measurements of their available acoustical cues are lacking. Here, these cues were determined from directional transfer functions (DTFs), the directional components of the head-related transfer functions, for eleven adult guinea pigs. In the frontal hemisphere, monaural spectral notches were present for frequencies from ~10 to 20 kHz; in general, the notch frequency increased with increasing sound source elevation and in azimuth toward the contralateral ear. The maximum ITDs calculated from low-pass filtered (2 kHz cutoff frequency) DTFs were ~250 µs, whereas the maximum ITD measured with low frequency tone pips was over 320 µs. A spherical head model underestimates ITD magnitude under normal conditions, but closely approximates values when the pinnae were removed. Interaural level differences (ILDs) strongly depended on location and frequency; maximum ILDs were < 10 dB for frequencies < 4 kHz and were as large as 40 dB for frequencies > 10 kHz. Removal of the pinna reduced the depth and sharpness of spectral notches, altered the acoustical axis, and reduced the acoustical gain, ITDs, and ILDs; however, spectral shape features and acoustical gain were not completely eliminated, suggesting a substantial contribution of the head and torso in altering the sounds present at the tympanic membrane. PMID:25051197

  10. The IUPAC Database of Rotational-Vibrational Energy Levels and Transitions of Water Isotopologues from Experiment and Theory

    NASA Astrophysics Data System (ADS)

    Császár, Attila G.; Furtenbacher, T.; Tennyson, Jonathan; Bernath, Peter F.; Brown, Linda R.; Campargue, Alain; Daumont, Ludovic; Gamache, Robert R.; Hodges, Joseph T.; Naumenko, Olga V.; Polyansky, Oleg L.; Rothman, Laurence S.; Vandaele, Ann Carine; Zobov, Nikolai F.

    2014-06-01

    The results of an IUPAC Task Group formed in 2004 on "A Database of Water Transitions from Experiment and Theory" (Project No. 2004-035-1-100) are presented. Energy levels and recommended labels involving exact and approximate quantum numbers for the main isotopologues of water in the gas phase, H216O, H218O, H217O, HD16O, HD18O, HD17O, D216O, D218O, and D217O, are determined from measured transition wavenumbers. The transition wavenumbers and energy levels are validated using the MARVEL (measured active rotational-vibrational energy levels) approach and first-principles nuclear motion computations. The extensive data, e.g., more than 200,000 transitions have been handled for H216O, including lines and levels that are required for analysis and synthesis of spectra, thermochemical applications, the construction of theoretical models, and the removal of spectral contamination by ubiquitous water lines. These datasets can also be used to assess where measurements are lacking for each isotopologue and to provide accurate frequencies for many yet-to-be measured transitions. The lack of high-quality frequency calibration standards in the near infrared is identified as an issue that has hindered the determination of high-accuracy energy levels at higher frequencies. The generation of spectra using the MARVEL energy levels combined with transition intensities computed using high accuracy ab initio dipole moment surfaces are discussed.

  11. The value of crossdating to retain high-frequency variability, climate signals, and extreme events in environmental proxies.

    PubMed

    Black, Bryan A; Griffin, Daniel; van der Sleen, Peter; Wanamaker, Alan D; Speer, James H; Frank, David C; Stahle, David W; Pederson, Neil; Copenheaver, Carolyn A; Trouet, Valerie; Griffin, Shelly; Gillanders, Bronwyn M

    2016-07-01

    High-resolution biogenic and geologic proxies in which one increment or layer is formed per year are crucial to describing natural ranges of environmental variability in Earth's physical and biological systems. However, dating controls are necessary to ensure temporal precision and accuracy; simple counts cannot ensure that all layers are placed correctly in time. Originally developed for tree-ring data, crossdating is the only such procedure that ensures all increments have been assigned the correct calendar year of formation. Here, we use growth-increment data from two tree species, two marine bivalve species, and a marine fish species to illustrate sensitivity of environmental signals to modest dating error rates. When falsely added or missed increments are induced at one and five percent rates, errors propagate back through time and eliminate high-frequency variability, climate signals, and evidence of extreme events while incorrectly dating and distorting major disturbances or other low-frequency processes. Our consecutive Monte Carlo experiments show that inaccuracies begin to accumulate in as little as two decades and can remove all but decadal-scale processes after as little as two centuries. Real-world scenarios may have even greater consequence in the absence of crossdating. Given this sensitivity to signal loss, the fundamental tenets of crossdating must be applied to fully resolve environmental signals, a point we underscore as the frontiers of growth-increment analysis continue to expand into tropical, freshwater, and marine environments. © 2016 John Wiley & Sons Ltd.

  12. Determination of seasonals using wavelets in terms of noise parameters changeability

    NASA Astrophysics Data System (ADS)

    Klos, Anna; Bogusz, Janusz; Figurski, Mariusz

    2015-04-01

    The reliable velocities of GNSS-derived observations are becoming of high importance nowadays. The fact on how we determine and subtract the seasonals may all cause the time series autocorrelation and affect uncertainties of linear parameters. The periodic changes in GNSS time series are commonly assumed as the sum of annual and semi-annual changes with amplitudes and phases being constant in time and the Least-Squares Estimation (LSE) is used in general to model these sine waves. However, not only seasonals' time-changeability, but also their higher harmonics should be considered. In this research, we focused on more than 230 globally distributed IGS stations that were processed at the Military University of Technology EPN Local Analysis Centre (MUT LAC) in Bernese 5.0 software. The network was divided into 7 different sub-networks with few of overlapping stations and processed separately with newest models. Here, we propose a wavelet-based trend and seasonals determination and removal of whole frequency spectrum between Chandler and quarter-annual periods from North, East and Up components and compare it with LSE-determined values. We used a Meyer symmetric, orthogonal wavelet and assumed nine levels of decomposition. The details from 6 up to 9 were analyzed here as periodic components with frequencies between 0.3-2.5 cpy. The characteristic oscillations for each of frequency band were pointed out. The details lower than 6 summed together with detrended approximation were considered as residua. The power spectral densities (PSDs) of original and decomposed data were stacked for North, East and Up components for each of sub-networks so as to show what power was removed with each of decomposition levels. Moreover, the noises that the certain frequency band follows (in terms of spectral indices of power-law dependencies) were estimated here using a spectral method and compared for all processed sub-networks. It seems, that lowest frequencies up to 0.7 cpy are characterized by lower spectral indices in comparison to higher ones being close to white noise. Basing on the fact, that decomposition levels overlap each other, the frequency-window choice becomes a main point in spectral index estimation. Our results were compared with those obtained by Maximum Likelihood Estimation (MLE) and possible differences as well as their impact on velocity uncertainties pointed out. The results show that the spectral indices estimated in time and frequency domains differ of 0.15 in maximum. Moreover, we compared the removed power basing on wavelet decomposition levels with the one subtracted with LSE, assuming the same periodicities. In comparison to LSE, the wavelet-based approach leaves the residua being closer to white noise with lower power-law amplitudes of them, what strictly reduces velocity uncertainties. The last approximation was analyzed here as long-term trend, being the non-linear and compared with LSE-determined linear one. It seems that these two trends differ at the level of 0.3 mm/yr in the most extreme case, what makes wavelet decomposition being useful for velocity determination.

  13. Advanced oxidation technology for H2S odor gas using non-thermal plasma

    NASA Astrophysics Data System (ADS)

    Tao, ZHU; Ruonan, WANG; Wenjing, BIAN; Yang, CHEN; Weidong, JING

    2018-05-01

    Non-thermal plasma technology is a new type of odor treatment processing. We deal with H2S from waste gas emission using non-thermal plasma generated by dielectric barrier discharge. On the basis of two criteria, removal efficiency and absolute removal amount, we deeply investigate the changes in electrical parameters and process parameters, and the reaction process of the influence of ozone on H2S gas removal. The experimental results show that H2S removal efficiency is proportional to the voltage, frequency, power, residence time and energy efficiency, while it is inversely proportional to the initial concentration of H2S gas, and ozone concentration. This study lays the foundations of non-thermal plasma technology for further commercial application.

  14. Mobile system for microwave removal of concrete surfaces

    DOEpatents

    White, Terry L.; Bigelow, Timothy S.; Schaich, Charles R.; Foster, Jr., Don

    1997-01-01

    A method and apparatus for the microwave removal of contaminated concrete surfaces. The apparatus comprises a housing adapted to pass over a support surface. The housing includes a waveguide for directing microwave energy to the surface at an angle maximizing absorption of microwave energy by the surface. The apparatus is further provided with a source of microwave energy operably associated with the waveguide, wherein the microwave energy has a frequency of between about 10.6 GHz and about 24 GHz and acts to remove the uppermost layer from the surface. The apparatus further includes a debris containment assembly comprising a vacuum assembly operably associated with the housing. The vacuum assembly is adapted to remove debris from the area adjacent the surface.

  15. Mobile system for microwave removal of concrete surfaces

    DOEpatents

    White, T.L.; Bigelow, T.S.; Schaich, C.R.; Foster, D. Jr.

    1997-06-03

    A method and apparatus are disclosed for the microwave removal of contaminated concrete surfaces. The apparatus comprises a housing adapted to pass over a support surface. The housing includes a waveguide for directing microwave energy to the surface at an angle maximizing absorption of microwave energy by the surface. The apparatus is further provided with a source of microwave energy operably associated with the waveguide, wherein the microwave energy has a frequency of between about 10.6 GHz and about 24 GHz and acts to remove the uppermost layer from the surface. The apparatus further includes a debris containment assembly comprising a vacuum assembly operably associated with the housing. The vacuum assembly is adapted to remove debris from the area adjacent the surface. 7 figs.

  16. High-frequency oscillations, extent of surgical resection, and surgical outcome in drug-resistant focal epilepsy

    PubMed Central

    Haegelen, Claire; Perucca, Piero; Châtillon, Claude-Edouard; Andrade-Valença, Luciana; Zelmann, Rina; Jacobs, Julia; Collins, D. Louis; Dubeau, François; Olivier, André; Gotman, Jean

    2013-01-01

    Summary Purpose Removal of areas generating high-frequency oscillations (HFOs) recorded from the intracerebral electroencephalography (iEEG) of patients with medically intractable epilepsy has been found to be correlated with improved surgical outcome. However, whether differences exist according to the type of epilepsy is largely unknown. We performed a comparative assessment of the impact of removing HFO-generating tissue on surgical outcome between temporal lobe epilepsy (TLE) and extratemporal lobe epilepsy (ETLE). We also assessed the relationship between the extent of surgical resection and surgical outcome. Methods We studied 30 patients with drug-resistant focal epilepsy, 21 with TLE and 9 with ETLE. Two thirds of the patients were included in a previous report and for these, clinical and imaging data were updated and follow-up was extended. All patients underwent iEEG investigations (500 Hz high-pass filter and 2,000 Hz sampling rate), surgical resection, and postoperative magnetic resonance imaging (MRI). HFOs (ripples, 80–250 Hz; fast ripples, >250 Hz) were identified visually on a 5–10 min interictal iEEG sample. HFO rates inside versus outside the seizure-onset zone (SOZ), in resected versus nonresected tissue, and their association with surgical outcome (ILAE classification) were assessed in the entire cohort, and in the TLE and ETLE subgroups. We also tested the correlation of resected brain hippocampal and amygdala volumes (as measured on postoperative MRIs) with surgical outcome. Key Findings HFO rates were significantly higher inside the SOZ than outside in the entire cohort and TLE subgroup, but not in the ETLE subgroup. In all groups, HFO rates did not differ significantly between resected and nonresected tissue. Surgical outcome was better when higher HFO rates were included in the surgical resection in the entire cohort and TLE subgroup, but not in the ETLE subgroup. Resected brain hippocampal and amygdala volumes were not correlated with surgical outcome. Significance In TLE, removal of HFO-generating areas may lead to improved surgical outcome. Less consistent findings emerge from ETLE, but these may be related to sample size limitations of this study. Size of resection, a factor that was ignored and that could have affected results of earlier studies did not influence results. PMID:23294353

  17. Effects of C/N ratio on nitrate removal and floc morphology of autohydrogenotrophic bacteria in a nitrate-containing wastewater treatment process.

    PubMed

    Nguyen, Tran Ngoc Phu; Chao, Shu-Ju; Chen, Pei-Chung; Huang, Chihpin

    2018-07-01

    The effects of C/N ratio of a nitrate-containing wastewater on nitrate removal performed by autohydrogenotrophic bacteria as well as on the morphological parameters of floc such as floc morphology, floc number distribution, mean particle size (MPS), aspect ratio and transparency were examined in this study. The results showed that the nitrate reduction rate increased with increasing C/N ratio from 0.5 to 10 and that the nitrogen removal of up to 95% was found at the C/N ratios of higher than 5 (between 0.5-10). Besides, high C/N ratio values reflected a corresponding high nitrite accumulation after 12-hr operation, and a fast decreasing rate of nitrite in the rest of operational time. The final pH values increased with the C/N ratio increasing from 0.5 to 2.5, but decreased with the C/N ratio increasing from 2.5 to 10. There were no significant changes in floc morphology with the MPSs ranging from 35 to 40μm. Small and medium-sized flocs were dominant in the sludge suspension, and the number of flocs increased with the increasing C/N ratios. Furthermore, the highest apparent frequency of 10% was observed at aspect ratios of 0.5 and 0.6, while the transparency of flocs changed from 0.1 to 0.7. Copyright © 2017. Published by Elsevier B.V.

  18. The impact of the driving frequency on the output flux of high-power InGaAlP-LEDs during high-current pulsed operation

    NASA Astrophysics Data System (ADS)

    Schulz, Benjamin; Morgott, Stefan

    2017-09-01

    Direct red light-emitting diodes based on InGaAlP comprise a strong temperature sensitivity regarding their output flux. In étendue-limited applications, like digital projectors, these LEDs are usually driven at current densities exceeding 3 A/mm2 in pulsed mode. The losses inside the semiconductor lead to a large amount of heat, which has to be removed most efficiently by a heatsink to keep the junction temperature as low as possible and therefore to obtain the maximum output flux. One important performance parameter is the thermal resistance Rth of the LED, which has been improved during the last few years, e.g. by the development of new high-power chips and packages. In our present approach, we investigated the influence of the driving frequency - which is closely related to the thermal impedance Zth - on the luminous and the radiant flux of red LEDs. A simulation model based on the electro-thermal analogies was implemented in SPICE and the optical and electrical characteristics of one LED type (OSRAM OSTAR Projection Power LE A P1W) were measured under application-related driving conditions while varying the parameters frequency, duty cycle, forward current, and heatsink temperature. The experimental results show clearly that the luminous and the radiant flux go up when the driving frequency is increased while the other parameters are maintained. Moreover, it can be noticed that the degree of this effect depends on the other parameters. The largest impact can be observed at the lowest tested duty cycle (30 %) and the highest tested current density (4 A/mm2) and heatsink temperature (80 °C). At this operating point, the luminous and the radiant flux increase by 20 % and 14 % respectively when raising the frequency from 240 Hz to 1920 Hz.

  19. Frequency spectrum analysis of finger photoplethysmographic waveform variability during haemodialysis.

    PubMed

    Javed, Faizan; Middleton, Paul M; Malouf, Philip; Chan, Gregory S H; Savkin, Andrey V; Lovell, Nigel H; Steel, Elizabeth; Mackie, James

    2010-09-01

    This study investigates the peripheral circulatory and autonomic response to volume withdrawal in haemodialysis based on spectral analysis of photoplethysmographic waveform variability (PPGV). Frequency spectrum analysis was performed on the baseline and pulse amplitude variabilities of the finger infrared photoplethysmographic (PPG) waveform and on heart rate variability extracted from the ECG signal collected from 18 kidney failure patients undergoing haemodialysis. Spectral powers were calculated from the low frequency (LF, 0.04-0.145 Hz) and high frequency (HF, 0.145-0.45 Hz) bands. In eight stable fluid overloaded patients (fluid removal of >2 L) not on alpha blockers, progressive reduction in relative blood volume during haemodialysis resulted in significant increase in LF and HF powers of PPG baseline and amplitude variability (P < 0.01), when expressed in mean-scaled units. The augmentation of LF powers in PPGV during haemodialysis may indicate the recovery and possibly further enhancement of peripheral sympathetic vascular modulation subsequent to volume unloading, whilst the increase in respiratory HF power in PPGV is most likely a sign of preload reduction. Spectral analysis of finger PPGV may provide valuable information on the autonomic vascular response to blood volume reduction in haemodialysis, and can be potentially utilized as a non-invasive tool for assessing peripheral circulatory control during routine dialysis procedure.

  20. A Novel Zero Velocity Interval Detection Algorithm for Self-Contained Pedestrian Navigation System with Inertial Sensors

    PubMed Central

    Tian, Xiaochun; Chen, Jiabin; Han, Yongqiang; Shang, Jianyu; Li, Nan

    2016-01-01

    Zero velocity update (ZUPT) plays an important role in pedestrian navigation algorithms with the premise that the zero velocity interval (ZVI) should be detected accurately and effectively. A novel adaptive ZVI detection algorithm based on a smoothed pseudo Wigner–Ville distribution to remove multiple frequencies intelligently (SPWVD-RMFI) is proposed in this paper. The novel algorithm adopts the SPWVD-RMFI method to extract the pedestrian gait frequency and to calculate the optimal ZVI detection threshold in real time by establishing the function relationships between the thresholds and the gait frequency; then, the adaptive adjustment of thresholds with gait frequency is realized and improves the ZVI detection precision. To put it into practice, a ZVI detection experiment is carried out; the result shows that compared with the traditional fixed threshold ZVI detection method, the adaptive ZVI detection algorithm can effectively reduce the false and missed detection rate of ZVI; this indicates that the novel algorithm has high detection precision and good robustness. Furthermore, pedestrian trajectory positioning experiments at different walking speeds are carried out to evaluate the influence of the novel algorithm on positioning precision. The results show that the ZVI detected by the adaptive ZVI detection algorithm for pedestrian trajectory calculation can achieve better performance. PMID:27669266

  1. Tracking Architecture Based on Dual-Filter with State Feedback and Its Application in Ultra-Tight GPS/INS Integration

    PubMed Central

    Zhang, Xi; Miao, Lingjuan; Shao, Haijun

    2016-01-01

    If a Kalman Filter (KF) is applied to Global Positioning System (GPS) baseband signal preprocessing, the estimates of signal phase and frequency can have low variance, even in highly dynamic situations. This paper presents a novel preprocessing scheme based on a dual-filter structure. Compared with the traditional model utilizing a single KF, this structure avoids carrier tracking being subjected to code tracking errors. Meanwhile, as the loop filters are completely removed, state feedback values are adopted to generate local carrier and code. Although local carrier frequency has a wide fluctuation, the accuracy of Doppler shift estimation is improved. In the ultra-tight GPS/Inertial Navigation System (INS) integration, the carrier frequency derived from the external navigation information is not viewed as the local carrier frequency directly. That facilitates retaining the design principle of state feedback. However, under harsh conditions, the GPS outputs may still bear large errors which can destroy the estimation of INS errors. Thus, an innovative integrated navigation filter is constructed by modeling the non-negligible errors in the estimated Doppler shifts, to ensure INS is properly calibrated. Finally, field test and semi-physical simulation based on telemetered missile trajectory validate the effectiveness of methods proposed in this paper. PMID:27144570

  2. Tracking Architecture Based on Dual-Filter with State Feedback and Its Application in Ultra-Tight GPS/INS Integration.

    PubMed

    Zhang, Xi; Miao, Lingjuan; Shao, Haijun

    2016-05-02

    If a Kalman Filter (KF) is applied to Global Positioning System (GPS) baseband signal preprocessing, the estimates of signal phase and frequency can have low variance, even in highly dynamic situations. This paper presents a novel preprocessing scheme based on a dual-filter structure. Compared with the traditional model utilizing a single KF, this structure avoids carrier tracking being subjected to code tracking errors. Meanwhile, as the loop filters are completely removed, state feedback values are adopted to generate local carrier and code. Although local carrier frequency has a wide fluctuation, the accuracy of Doppler shift estimation is improved. In the ultra-tight GPS/Inertial Navigation System (INS) integration, the carrier frequency derived from the external navigation information is not viewed as the local carrier frequency directly. That facilitates retaining the design principle of state feedback. However, under harsh conditions, the GPS outputs may still bear large errors which can destroy the estimation of INS errors. Thus, an innovative integrated navigation filter is constructed by modeling the non-negligible errors in the estimated Doppler shifts, to ensure INS is properly calibrated. Finally, field test and semi-physical simulation based on telemetered missile trajectory validate the effectiveness of methods proposed in this paper.

  3. Canadian Penning Trap Mass Measurements using a Position Sensitive MCP

    NASA Astrophysics Data System (ADS)

    Kuta, Trenton; Aprahamian, Ani; Marley, Scott; Nystrom, Andrew; Clark, Jason; Perez Galvan, Adrian; Hirsh, Tsviki; Savard, Guy; Orford, Rodney; Morgan, Graeme

    2015-10-01

    The primary focus of the Canadian Penning Trap (CPT) located at Argonne National Lab is to determine the masses of various isotopes produced in the spontaneous fission of Californium. Currently, the CPT is operating in conjunction with CARIBU at the ATLAS facility in an attempt to measure neutron-rich nuclei produced by a 1.5 Curie source of Californium 252. The masses of nuclei produced in fission is accomplished by measuring the cyclotron frequency of the isotopes circling within the trap. This frequency is determined by a position sensitive MCP, which records the relative position of the isotope in the trap at different times. Using these position changes over time in connection with a center spot, angles between these positions are calculated and used to determine the frequency. Most of the work currently being conducted on the CPT is focused on the precision of these frequency measurements. The use of traps has revolutionized the measurements of nuclear masses to very high precision. The optimization methods employed here include focusing the beam in order to reduce the spread on the position of the isotope as well as the tuning of the MR-ToF, a mass separator that is intended on removing contaminants in the beam. This work was supported by the nuclear Grant PHY-1419765 for the University of Notre Dame.

  4. Neuronal Responses in the Globus Pallidus during Subthalamic Nucleus Electrical Stimulation in Normal and Parkinson's Disease Model Rats

    PubMed Central

    Ryu, Sang Baek; Bae, Eun Kyung; Kim, Jinhyung; Hwang, Yong Sup; Im, Changkyun; Chang, Jin Woo; Shin, Hyung-Cheul

    2013-01-01

    Deep brain stimulation (DBS) of the subthalamic nucleus (STN) has been widely used as a treatment for the movement disturbances caused by Parkinson's disease (PD). Despite successful application of DBS, its mechanism of therapeutic effect is not clearly understood. Because PD results from the degeneration of dopamine neurons that affect the basal ganglia (BG) network, investigation of neuronal responses of BG neurons during STN DBS can provide informative insights for the understanding of the mechanism of therapeutic effect. However, it is difficult to observe neuronal activity during DBS because of large stimulation artifacts. Here, we report the observation of neuronal activities of the globus pallidus (GP) in normal and PD model rats during electrical stimulation of the STN. A custom artifact removal technique was devised to enable monitoring of neural activity during stimulation. We investigated how GP neurons responded to STN stimulation at various stimulation frequencies (10, 50, 90 and 130 Hz). It was observed that activities of GP neurons were modulated by stimulation frequency of the STN and significantly inhibited by high frequency stimulation above 50 Hz. These findings suggest that GP neuronal activity is effectively modulated by STN stimulation and strongly dependent on the frequency of stimulation. PMID:23946689

  5. Electrically-pumped 850-nm micromirror VECSELs.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geib, Kent Martin; Peake, Gregory Merwin; Serkland, Darwin Keith

    Vertical-external-cavity surface-emitting lasers (VECSELs) combine high optical power and good beam quality in a device with surface-normal output. In this paper, we describe the design and operating characteristics of an electrically-pumped VECSEL that employs a wafer-scale fabrication process and operates at 850 nm. A curved micromirror output coupler is heterogeneously integrated with AlGaAs-based semiconductor material to form a compact and robust device. The structure relies on flip-chip bonding the processed epitaxial material to an aluminum nitride mount; this heatsink both dissipates thermal energy and permits high frequency modulation using coplanar traces that lead to the VECSEL mesa. Backside emission ismore » employed, and laser operation at 850 nm is made possible by removing the entire GaAs substrate through selective wet etching. While substrate removal eliminates absorptive losses, it simultaneously compromises laser performance by increasing series resistance and degrading the spatial uniformity of current injection. Several aspects of the VECSEL design help to mitigate these issues, including the use of a novel current-spreading n type distributed Bragg reflector (DBR). Additionally, VECSEL performance is improved through the use of a p-type DBR that is modified for low thermal resistance.« less

  6. Electrically pumped 850-nm micromirror VECSELs

    NASA Astrophysics Data System (ADS)

    Keeler, Gordon A.; Serkland, Darwin K.; Geib, Kent M.; Peake, Gregory M.; Mar, Alan

    2005-03-01

    Vertical-external-cavity surface-emitting lasers (VECSELs) combine high optical power and good beam quality in a device with surface-normal output. In this paper, we describe the design and operating characteristics of an electrically-pumped VECSEL that employs a wafer-scale fabrication process and operates at 850 nm. A curved micromirror output coupler is heterogeneously integrated with AlGaAs-based semiconductor material to form a compact and robust device. The structure relies on flip-chip bonding the processed epitaxial material to an aluminum nitride mount; this heatsink both dissipates thermal energy and permits high frequency modulation using coplanar traces that lead to the VECSEL mesa. Backside emission is employed, and laser operation at 850 nm is made possible by removing the entire GaAs substrate through selective wet etching. While substrate removal eliminates absorptive losses, it simultaneously compromises laser performance by increasing series resistance and degrading the spatial uniformity of current injection. Several aspects of the VECSEL design help to mitigate these issues, including the use of a novel current-spreading n type distributed Bragg reflector (DBR). Additionally, VECSEL performance is improved through the use of a p-type DBR that is modified for low thermal resistance.

  7. Modular Rake of Pitot Probes

    NASA Technical Reports Server (NTRS)

    Dunlap, Timothy A.; Henry, Michael W.; Homyk, Raymond P.

    2004-01-01

    The figure presents selected views of a modular rake of 17 pitot probes for measuring both transient and steady-state pressures in a supersonic wind tunnel. In addition to pitot tubes visible in the figure, the probe modules contain (1) high-frequency dynamic-pressure transducers connected through wires to remote monitoring circuitry and (2) flow passages that lead to tubes that, in turn, lead to remote steady-state pressure transducers. Prior pitot-probe rakes were fabricated as unitary structures, into which the individual pitot probes were brazed. Repair or replacement of individual probes was difficult, costly, and time-consuming because (1) it was necessary to remove entire rakes in order to unbraze individual malfunctioning probes and (2) the heat of unbrazing a failed probe and of brazing a new probe in place could damage adjacent probes. In contrast, the modules in the present probe are designed to be relatively quickly and easily replaceable with no heating and, in many cases, without need for removal of the entire rake from the wind tunnel. To remove a malfunctioning probe, one first removes a screw-mounted V-cross-section cover that holds the probe and adjacent probes in place. Then one removes a screw-mounted cover plate to gain access to the steady-state pressure tubes and dynamicpressure wires. Next, one disconnects the tube and wires of the affected probe. Finally, one installs a new probe in the reverse of the aforementioned sequence. The wire connections can be made by soldering, but to facilitate removal and installation, they can be made via miniature plugs and sockets. The connections between the probe flow passages and the tubes leading to the remote pressure sensors can be made by use of any of a variety of readily available flexible tubes that can be easily pulled off and slid back on for removal and installation, respectively.

  8. The evolution of methods for noise prediction of high speed rotors and propellers in the time domain

    NASA Technical Reports Server (NTRS)

    Farassat, F.

    1986-01-01

    Linear wave equation models which have been used over the years at NASA Langley for describing noise emissions from high speed rotating blades are summarized. The noise sources are assumed to lie on a moving surface, and analysis of the situation has been based on the Ffowcs Williams-Hawkings (FW-H) equation. Although the equation accounts for two surface and one volume source, the NASA analyses have considered only the surface terms. Several variations on the FW-H model are delineated for various types of applications, noting the computational benefits of removing the frequency dependence of the calculations. Formulations are also provided for compact and noncompact sources, and features of Long's subsonic integral equation and Farassat's high speed integral equation are discussed. The selection of subsonic or high speed models is dependent on the Mach number of the blade surface where the source is located.

  9. Mechanical Vibrations Reduce the Intervertebral Disc Swelling and Muscle Atrophy from Bed Rest

    NASA Technical Reports Server (NTRS)

    Holguin, Nilsson; Muir, Jesse; Evans, Harlan J.; Qin, Yi-Xian; Rubin, Clinton; Wagshul, Mark; Judex, Stefan

    2007-01-01

    Loss of functional weight bearing, such as experienced during space flight or bed rest (BR), distorts intervertebral disc (IVD) and muscle morphology. IVDs are avascular structures consisting of cells that may derive their nutrition and waste removal from the load induced fluid flow into and out of the disc. A diurnal cycle is produced by forces related to weight bearing and muscular activity, and comprised of a supine and erect posture over a 24 hr period. A diurnal cycle will include a disc volume change of approx. 10-13%. However, in space there are little or no diurnal changes because of the microgravity, which removes the gravitational load and compressive forces to the back muscles. The BR model and the etiology of the disc swelling and muscle atrophy could provide insight into those subjects confined to bed for chronic disease/injury and aging. We hypothesize that extremely low-magnitude, high frequency mechanical vibrations will abate the disc degeneration and muscle loss associated with long-term BR.

  10. Automated Removal of Bad-Baseline Spectra from ACSIS/HARP Heterodyne Time Series

    NASA Astrophysics Data System (ADS)

    Currie, M. J.

    2013-10-01

    Heterodyne time-series spectral data often exhibit distorted or noisy baselines. These are either transient due to external interference or pickup; or affect a receptor throughout an observation or extended period, possibly due to a poor cable connection. While such spectra can be excluded manually, this is time consuming and prone to omission, especially for the high-frequency interference affecting just one or two spectra in typically several to twenty thousand, yet can produce undesirable artifacts in the reduced spectral cube. Further astronomers have tended to reject an entire receptor if any of its spectra are suspect; as a consequence the reduced products have lower signal-to-noise, and enhanced graticule patterns due to the variable coverage and detector relative sensitivities. This paper illustrates some of the types of aberrant spectra for ACSIS/HARP on the James Clerk Maxwell Telescope and the algorithms used to identify and remove them, applied within the ORAC-DR pipeline, and compares an integrated map with and without baseline filtering.

  11. Wave-particle interactions in rotating mirrorsa)

    NASA Astrophysics Data System (ADS)

    Fetterman, Abraham J.; Fisch, Nathaniel J.

    2011-05-01

    Wave-particle interactions in E ×B rotating plasmas feature an unusual effect: particles are diffused by waves in both potential energy and kinetic energy. This wave-particle interaction generalizes the alpha channeling effect, in which radio frequency waves are used to remove alpha particles collisionlessly at low energy. In rotating plasmas, the alpha particles may be removed at low energy through the loss cone, and the energy lost may be transferred to the radial electric field. This eliminates the need for electrodes in the mirror throat, which have presented serious technical issues in past rotating plasma devices. A particularly simple way to achieve this effect is to use a high azimuthal mode number perturbation on the magnetic field. Rotation can also be sustained by waves in plasmas without a kinetic energy source. This type of wave has been considered for plasma centrifuges used for isotope separation. Energy may also be transferred from the electric field to particles or waves, which may be useful for ion heating and energy generation.

  12. Pilot-Assisted Channel Estimation for Orthogonal Multi-Carrier DS-CDMA with Frequency-Domain Equalization

    NASA Astrophysics Data System (ADS)

    Shima, Tomoyuki; Tomeba, Hiromichi; Adachi, Fumiyuki

    Orthogonal multi-carrier direct sequence code division multiple access (orthogonal MC DS-CDMA) is a combination of time-domain spreading and orthogonal frequency division multiplexing (OFDM). In orthogonal MC DS-CDMA, the frequency diversity gain can be obtained by applying frequency-domain equalization (FDE) based on minimum mean square error (MMSE) criterion to a block of OFDM symbols and can improve the bit error rate (BER) performance in a severe frequency-selective fading channel. FDE requires an accurate estimate of the channel gain. The channel gain can be estimated by removing the pilot modulation in the frequency domain. In this paper, we propose a pilot-assisted channel estimation suitable for orthogonal MC DS-CDMA with FDE and evaluate, by computer simulation, the BER performance in a frequency-selective Rayleigh fading channel.

  13. Estimation of frequency offset in mobile satellite modems

    NASA Technical Reports Server (NTRS)

    Cowley, W. G.; Rice, M.; Mclean, A. N.

    1993-01-01

    In mobilesat applications, frequency offset on the received signal must be estimated and removed prior to further modem processing. A straightforward method of estimating the carrier frequency offset is to raise the received MPSK signal to the M-th power, and then estimate the location of the peak spectral component. An analysis of the lower signal to noise threshold of this method is carried out for BPSK signals. Predicted thresholds are compared to simulation results. It is shown how the method can be extended to pi/M MPSK signals. A real-time implementation of frequency offset estimation for the Australian mobile satellite system is described.

  14. Removal of floating dust in glow discharge using plasma jet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ticos, C. M.; Jepu, I.; Lungu, C. P.

    2010-07-05

    Dust can be an inconvenient source of impurities in plasma processing reactors and in many cases it can cause damage to the plasma-treated surfaces. A technique for dust expulsion out of the trapping region in plasma is presented here, based on the wind force exerted on dust particles by a pulsed plasma jet. Its applicability is demonstrated by removing floating dust in the sheath of parallel-plate capacitive radio-frequency plasma.

  15. Theoretical and simulated performance for a novel frequency estimation technique

    NASA Technical Reports Server (NTRS)

    Crozier, Stewart N.

    1993-01-01

    A low complexity, open-loop, discrete-time, delay-multiply-average (DMA) technique for estimating the frequency offset for digitally modulated MPSK signals is investigated. A nonlinearity is used to remove the MPSK modulation and generate the carrier component to be extracted. Theoretical and simulated performance results are presented and compared to the Cramer-Rao lower bound (CRLB) for the variance of the frequency estimation error. For all signal-to-noise ratios (SNR's) above threshold, it is shown that the CRLB can essentially be achieved with linear complexity.

  16. Technical advantages of disk laser technology in short and ultrashort pulse processes

    NASA Astrophysics Data System (ADS)

    Graham, P.; Stollhof, J.; Weiler, S.; Massa, S.; Faisst, B.; Denney, P.; Gounaris, E.

    2011-03-01

    This paper demonstrates that disk-laser technology introduces advantages that increase efficiency and allows for high productivity in micro-processing in both the nanosecond (ns) and picosecond (ps) regimes. Some technical advantages of disk technology include not requiring good pump beam quality or special wavelengths for pumping of the disk, high optical efficiencies, no thermal lensing effects and a possible scaling of output power without an increase of pump beam quality. With cavity-dumping, the pulse duration of the disk laser can be specified between 30 and hundreds of nanoseconds, but is independent of frequency, thus maintaining process stability. TRUMPF uses this technology in the 750 watts average power laser TruMicro 7050. High intensity, along with fluency, is important for high ablation rates in thinfilm removal. Thus, these ns lasers show high removal rates, above 60 cm2/s, in thin-film solar cell production. In addition, recent results in paint-stripping of aerospace material prove the green credentials and high processing rates inherent with this technology as it can potentially replace toxic chemical processes. The ps disk technology meanwhile is used in, for example, scribing of solar cells, wafer dicing and drilling injector nozzles, as the pulse duration is short enough to minimize heat input in the laser-matter interaction. In the TruMicro Series 5000, the multi-pass regenerative amplifier stage combines high optical-optical efficiencies together with excellent output beam quality for pulse durations of only 6 ps and high pulse energies of up to 0.25 mJ.

  17. Thermocatalytic treatment of biomass tar model compounds via radio frequency.

    PubMed

    Anis, Samsudin; Zainal, Z A; Bakar, M Z A

    2013-05-01

    A new effective RF tar thermocatalytic treatment process with low energy intensive has been proposed to remove tar from biomass gasification. Toluene and naphthalene as biomass tar model compounds were removed via both thermal and catalytic treatment over a wide temperature range from 850 °C to 1200 °C and 450 °C to 900 °C, respectively at residence time of 0-0.7 s. Thermal characteristics of the new technique are also described in this paper. This study clearly clarified that toluene was much easier to be removed than naphthalene. Soot was found as the final product of thermal treatment of the tar model and completely removed during catalytic treatment. Radical reactions generated by RF non-thermal effect improve the tar removal. The study showed that Y-zeolite has better catalytic activity compared to dolomite on toluene and naphthalene removal due to its acidic nature and large surface area, even at lower reaction temperature of about 550 °C. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Removal of Stationary Sinusoidal Noise from Random Vibration Signals.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Brian; Cap, Jerome S.

    In random vibration environments, sinusoidal line noise may appear in the vibration signal and can affect analysis of the resulting data. We studied two methods which remove stationary sine tones from random noise: a matrix inversion algorithm and a chirp-z transform algorithm. In addition, we developed new methods to determine the frequency of the tonal noise. The results show that both of the removal methods can eliminate sine tones in prefabricated random vibration data when the sine-to-random ratio is at least 0.25. For smaller ratios down to 0.02 only the matrix inversion technique can remove the tones, but the metricsmore » to evaluate its effectiveness also degrade. We also found that using fast Fourier transforms best identified the tonal noise, and determined that band-pass-filtering the signals prior to the process improved sine removal. When applied to actual vibration test data, the methods were not as effective at removing harmonic tones, which we believe to be a result of mixed-phase sinusoidal noise.« less

  19. The formation mechanism and evolution of ps-laser-induced high-spatial-frequency periodic surface structures on titanium

    NASA Astrophysics Data System (ADS)

    Pan, A. F.; Wang, W. J.; Mei, X. S.; Yang, H. Z.; Sun, X. F.

    2017-01-01

    We report the formation and evolution mechanisms of HSFLs (high-spatial-frequency laser-induced periodic surface structures) on the commercial pure titanium under 10-ps 532-nm-wavelength laser irradiation. At a lower peak laser fluence, HSFLs in the rough zone are first formed along the surface texture. Subsequently, HSFLs in the flat zone are formed with an orientation parallel to the laser polarization direction. The formation of HSFLs can be attributed to the parallel orientation of the initial periodic modulation of the electron plasma concentration to the laser polarization direction. In particular, the formation of HSFLs along the surface texture occurs because the absorbed laser energy density is along the surface texture. At a higher peak laser fluence, two types of HSFLs appear together with LSFLs. The first type involves HSFLs that initially cover the concave part of the LSFL (low-spatial-frequency laser-induced periodic surface structures) and penetrate inward as the number of spot overlaps increases. This formation mechanism can be attributed to cavitation instability. The second type involves HSFLs that are initially in the convex part of the LSFL, and they are transformed into oxidized nanodots as the number of spot overlaps increases. The oxidized nanodots increase the absorption of laser energy in titanium, which leads to the ablation and removal of the oxidized material. Therefore, the surface of the LSFL becomes smooth.

  20. Experimental Butchering of a Chimpanzee Carcass for Archaeological Purposes

    PubMed Central

    Saladié, Palmira; Cáceres, Isabel; Huguet, Rosa; Rodríguez-Hidalgo, Antonio; Santander, Borís; Ollé, Andreu; Gabucio, Mª Joana; Martín, Patricia; Marín, Juan

    2015-01-01

    Two archaeological assemblages from the Sierra de Atapuerca sites show evidence of anthropogenic cannibalism. These are the late Early Pleistocene level TD6-2 at Gran Dolina, and the Bronze Age level MIR4 in the Mirador Cave. Despite the chronological distance between these two assemblages, they share the common feature that the human remains exhibit a high frequency of anthropogenic modifications (cut marks, percussion pits and notches and peeling). This frequency could denote special treatment of bodies, or else be the normal result of the butchering process. In order to test these possibilities, we subjected a chimpanzee carcass to a butchering process. The processing was intensive and intended to simulate preparation for consumption. In doing this, we used several simple flakes made from quartzite and chert from quarries in the Sierra de Atapuerca. The skull, long bones, metapodials and phalanges were also fractured in order to remove the brain and bone marrow. As a result, about 40% of the remains showed some kind of human modification. The frequency, distribution and characteristics of these modifications are very similar to those documented on the remains of Homo antecessor from TD6-2. In case of the MIR4 assemblage, the results are similar except in the treatment of skulls. Our results indicate that high frequencies of anthropogenic modifications are common after an intensive butchering process intended to prepare a hominin body for consumption in different contexts (both where there was possible ritual behavior and where this was not the case and the modifications are not the result of special treatment). PMID:25793521

Top