Sample records for repeat-insult patch test

  1. The human repeated insult patch test in the 21st century: a commentary.

    PubMed

    Basketter, David A

    2009-01-01

    The human repeated insult patch test (HRIPT) is over half a century old, but is still used in several countries as a confirmatory test in the safety evaluation of skin sensitizers. This is despite the criticism it receives from an ethical perspective and regarding the scientific validity of such testing. In this commentary, the HRIPT is reviewed, with emphasis on ethical aspects and where the test can, and cannot, contribute in a scientifically meaningful manner to safety evaluation. It is concluded that where there is a specific rationale for testing, for example, to substantiate a no-effect level for a sensitizing chemical or to ensure that matrix effects are not making an unexpected contribution to sensitizing potency, then rigorous independent review may confirm that an HRIPT is ethical and scientifically justifiable. The possibility that sensitization may be induced in volunteers dictates that HRIPTs should be conducted rarely and in cases where the benefits overwhelmingly outweigh the risk. However, for the very large majority of HRIPTs conducted concerning the risk of skin sensitization, there is neither scientific justification nor any other merit.

  2. The sensitization potential of sunscreen after ablative fractional skin resurfacing using modified human repeated insult patch test.

    PubMed

    Boonchai, Waranya; Sathaworawong, Angkana; Wongpraparut, Chanisada; Wanitphakdeedecha, Rungsima

    2015-10-01

    Ablative fractional skin resurfacing has become popular and proven to be useful in treating scars, photoaging and wrinkles. Although post-inflammatory hyperpigmentation (PIH) is the most common complication especially in dark-skinned patients like Asian. Several modalities have been used to overcome the PIH. To determine the sensitization potential of sunscreen applied immediately after ablative fractional skin resurfacing. Sixty volunteers were recruited. Of these 30 subjects were from previous ablative fractional skin resurfacing study who applied broad-spectrum sunscreen containing anti-inflammatory agent starting on the first day after resurfacing and another 30 non-resurfacing subjects had applied the same sunscreen on the intact skin. All subjects were patch/photopatch tested for sensitization study by using modified human repeated insult patch test (HRIPT). There were significantly higher sensitization rate of UV-filter, octocrylene and the sunscreen in resurfacing group than in non-resurfacing group. Early application of sunscreen after ablative fractional skin resurfacing has increased the incidence of sensitization potential of sunscreen. The sunscreen is recommended to start using from D3 after fractional ablative skin resurfacing to ensure the complete recovery of skin barrier and minimize the risk of sensitization.

  3. Hydroxyisohexyl 3-cyclohexene carboxaldehyde allergy: relationship between patch test and repeated open application test thresholds.

    PubMed

    Fischer, L A; Menné, T; Avnstorp, C; Kasting, G B; Johansen, J D

    2009-09-01

    Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) is a synthetic fragrance ingredient. Case reports of allergy to HICC appeared in the 1980s, and HICC has recently been included in the European baseline series. Human elicitation dose-response studies performed with different allergens have shown a significant relationship between the patch-test threshold and the repeated open application test (ROAT) threshold, which mimics some real-life exposure situations. Fragrance ingredients are special as significant amounts of allergen may evaporate from the skin. The study aimed to investigate the relationship between elicitation threshold doses at the patch test and the ROAT, using HICC as the allergen. The expected evaporation rate was calculated. Seventeen HICC-allergic persons were tested with a dilution series of HICC in a patch test and a ROAT (duration up to 21 days). Seventeen persons with no HICC allergy were included as control group for the ROAT. Results The response frequency to the ROAT (in microg HICC cm(-2) per application) was significantly higher than the response frequency to the patch test at one of the tested doses. Furthermore the response rate to the accumulated ROAT dose was significantly lower at half of the doses compared with the patch test. The evaporation rate of HICC was calculated to be 72% over a 24-h period. The ROAT threshold in dose per area per application is lower than the patch test threshold; furthermore the accumulated ROAT threshold is higher than the patch test threshold, which can probably be explained by the evaporation of HICC from the skin in the open test.

  4. Quantitative patch and repeated open application testing in hydroxyisohexyl 3-cyclohexene carboxaldehyde sensitive-patients.

    PubMed

    Schnuch, Axel; Uter, Wolfgang; Dickel, Heinrich; Szliska, Christiane; Schliemann, Sibylle; Eben, Ricarda; Ruëff, Franziska; Gimenez-Arnau, Ana; Löffler, Harald; Aberer, Werner; Frambach, Yvonne; Worm, Margitta; Niebuhr, Margarete; Hillen, Uwe; Martin, Vera; Jappe, Uta; Frosch, Peter J; Mahler, Vera

    2009-09-01

    To identify the concentration of the fragrance compound hydroxyisohexyl 3-cyclohexene carboxaldehyde (INCI) (HICC) that is sufficiently low not to cause an allergic reaction in patients with proven sensitization. Repeated open application testing (ROAT) in 64 subjects with 2 preparations (perfume and cream) in different concentration (0.005-2.5%). Confirmatory patch testing with four preparations in two different concentrations (2.5% and 5%). The concentrations of HICC being tolerated by 90% of those sensitized to HICC are estimated as <88.2 ppm (cream) and <270 ppm (perfume) equivalent to 1.2 microg/cm(2) (perfume) and 4.9 microg/cm(2) (cream). Patch test preparations differed with regard to sensitivity (88.5-98.1%) and specificity (37.5-87.5%) against the ROAT result as external criterion. ROAT concentrations and the reaction strength in patch testing were inversely correlated (Kendall's tau-b: 0.69), both indicating the existence of different degrees of susceptibility. To protect 90% (50%) of people sensitized, the use concentration should be in the range of 0.009-0.027% (0.18-0.34%), depending on the product type. Taking into account these results, excessive concentrations should be avoided, as this would continue to sensitize people. Close monitoring is indispensable to prove the efficacy of any recommendations aiming to prevent induction.

  5. Effects of different base agents on prediction of skin irritation by sodium lauryl sulfate using patch testing and repeated application test.

    PubMed

    Horita, Kotomi; Horita, Daisuke; Tomita, Hiroyuki; Yasoshima, Mitsue; Yagami, Akiko; Matsunaga, Kayoko

    2017-05-01

    Animal testing for cosmetics was banned in the European Union (EU) in 2013; therefore, human tests to predict and ensure skin safety such as the patch test or usage test are now in demand in Japan as well as in the EU. In order to investigate the effects of different bases on the findings of tests to predict skin irritation, we performed patch testing (PT) and the repeated application test (RAT) using sodium lauryl sulfate (SLS), a well-known irritant, dissolved in 6 different base agents to examine the effects of these bases on skin irritation by SLS. The bases for PT were distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream. The concentrations of SLS were 0.2% and 0.5%. Twelve different base combinations were applied to the normal back skin of 19 individuals for 24h. RAT was performed with distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream containing SLS at concentrations of 0.2%, 2%, and 5%, being applied to the arms of the same PT subjects. The test preparation of each base was applied at the same site, with 0.2% SLS being used in the first week, 2% SLS in the following week, and 5% SLS in the final week. The results of PT revealed that skin irritation scores varied when SLS at the same concentration was dissolved in a different base. The results of RAT showed that although skin irritation appeared with every base at a concentration of 5%, the positive rate was approximately the same. In conclusion, our results suggest that skin irritation elicited in PT depends on the base, while in RAT, it does not depend on the type of base employed. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Patch Test Negative Generalized Dermatitis.

    PubMed

    Spiker, Alison; Mowad, Christen

    2016-01-01

    Allergic contact dermatitis is a common condition in dermatology. Patch testing is the criterion standard for diagnosis. However, dermatitis is not always caused by an allergen, and patch testing does not identify a culprit in every patient. Generalized dermatitis, defined as eczematous dermatitis affecting greater than 3 body sites, is often encountered in dermatology practice, especially patch test referral centers. Management for patients with generalized dermatitis who are patch test negative is challenging. The purpose of this article is to outline an approach to this challenging scenario and summarize the paucity of existing literature on patch test negative generalized dermatitis.

  7. The dose-response relationship between the patch test and ROAT and the potential use for regulatory purposes.

    PubMed

    Fischer, Louise Arup; Voelund, Aage; Andersen, Klaus Ejner; Menné, Torkil; Johansen, Jeanne Duus

    2009-10-01

    Allergic contact dermatitis is common and can be prevented. The relationship between thresholds for patch tests and the repeated open application test (ROAT) is unclear. It would be desirable if patch test and ROAT data from already sensitized individuals could be used in prevention. The aim was to develop an equation that could predict the response to an allergen in a ROAT based on the dose-response curve derived by patch testing. Results from two human experimental elicitation studies with non-volatile allergens, nickel and the preservative methyldibromo glutaronitrile (MDBGN), were analysed by logistic dose-response statistics. The relation for volatile compounds was investigated using the results from experiments with the fragrance chemicals hydroxyisohexyl 3-cyclohexene carboxaldehyde and isoeugenol. For non-volatile compounds, the outcome of a ROAT can be estimated from the patch test by: ED(xx)(ROAT) = 0.0296 ED(xx)(patch test). For volatile compounds, the equation predicts that the response in the ROAT is more severe than the patch test response, but it overestimates the response. This equation may be used for non-volatile compounds other than nickel and MDBGN, after further validation. The relationship between the patch test and the ROAT can be used for prevention, to set safe levels of allergen exposure based on patch test data.

  8. Comparing reliabilities of strip and conventional patch testing.

    PubMed

    Dickel, Heinrich; Geier, Johannes; Kreft, Burkhard; Pfützner, Wolfgang; Kuss, Oliver

    2017-06-01

    The standardized protocol for performing the strip patch test has proven to be valid, but evidence on its reliability is still missing. To estimate the parallel-test reliability of the strip patch test as compared with the conventional patch test. In this multicentre, prospective, randomized, investigator-blinded reliability study, 132 subjects were enrolled. Simultaneous duplicate strip and conventional patch tests were performed with the Finn Chambers ® on Scanpor ® tape test system and the patch test preparations nickel sulfate 5% pet., potassium dichromate 0.5% pet., and lanolin alcohol 30% pet. Reliability was estimated by the use of Cohen's kappa coefficient. Parallel-test reliability values of the three standard patch test preparations turned out to be acceptable, with slight advantages for the strip patch test. The differences in reliability were 9% (95%CI: -8% to 26%) for nickel sulfate and 23% (95%CI: -16% to 63%) for potassium dichromate, both favouring the strip patch test. The standardized strip patch test method for the detection of allergic contact sensitization in patients with suspected allergic contact dermatitis is reliable. Its application in routine clinical practice can be recommended, especially if the conventional patch test result is presumably false negative. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    PubMed

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  10. Some Insults are Easier to Detect: The Embodied Insult Detection Effect

    PubMed Central

    Wellsby, Michele; Siakaluk, Paul D.; Pexman, Penny M.; Owen, William J.

    2010-01-01

    In the present research we examined the effects of bodily experience on processing of insults in a series of semantic categorization tasks we call insult detection tasks (i.e., participants decided whether presented stimuli were insults or not). Two types of insults were used: more embodied insults (e.g., asswipe, ugly), and less embodied insults (e.g., cheapskate, twit), as well as non-insults. In Experiments 1 and 2 the non-insults did not form a single, coherent category (e.g., airbase, polka), whereas in Experiment 3 all the non-insults were compliments (e.g., eyeful, honest). Regardless of type of non-insult used, we observed facilitatory embodied insult effects such that more embodied insults were responded to faster and recalled more often than less embodied insults. In Experiment 4 we used a larger set of insults as stimuli, which allowed hierarchical multiple regression analyses. These analyses revealed that bodily experience ratings accounted for a significant amount of unique response latency, response error, and recall variability for responses to insults, even with several other predictor variables (e.g., frequency, offensiveness, imageability) included in the analyses: responses were faster and more accurate, and there was greater recall for relatively more embodied insults. These results demonstrate that conceptual knowledge of insults is grounded in knowledge gained through bodily experience. PMID:21738511

  11. Safety and efficacy of personal care products containing colloidal oatmeal.

    PubMed

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period.

  12. Safety and efficacy of personal care products containing colloidal oatmeal

    PubMed Central

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Background Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. Methods In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. Results We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Conclusion Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period. PMID:23204849

  13. Repeated methamphetamine administration differentially alters fos expression in caudate-putamen patch and matrix compartments and nucleus accumbens.

    PubMed

    Jedynak, Jakub P; Cameron, Courtney M; Robinson, Terry E

    2012-01-01

    The repeated administration of psychostimulant drugs produces a persistent and long-lasting increase ("sensitization") in their psychomotor effects, which is thought to be due to changes in the neural circuitry that mediate these behaviors. One index of neuronal activation used to identify brain regions altered by repeated exposure to drugs involves their ability to induce immediate early genes, such as c-fos. Numerous reports have demonstrated that past drug experience alters the ability of drugs to induce c-fos in the striatum, but very few have examined Fos protein expression in the two major compartments in the striatum--the so-called patch/striosome and matrix. In the present study, we used immunohistochemistry to investigate the effects of pretreatment with methamphetamine on the ability of a subsequent methamphetamine challenge to induce Fos protein expression in the patch and matrix compartments of the dorsolateral and dorsomedial caudate-putamen and in the ventral striatum (nucleus accumbens). Animals pretreated with methamphetamine developed robust psychomotor sensitization. A methamphetamine challenge increased the number of Fos-positive cells in all areas of the dorsal and ventral striatum. However, methamphetamine challenge induced Fos expression in more cells in the patch than in the matrix compartment in the dorsolateral and dorsomedial caudate-putamen. Furthermore, past experience with methamphetamine increased the number of methamphetamine-induced Fos positive cells in the patch compartment of the dorsal caudate putamen, but not in the matrix or in the core or shell of the nucleus accumbens. These data suggest that drug-induced alterations in the patch compartment of the dorsal caudate-putamen may preferentially contribute to some of the enduring changes in brain activity and behavior produced by repeated treatment with methamphetamine.

  14. Urushiol Patch Test Using the T.R.U.E. TEST System.

    PubMed

    Kim, Yesul; Longenecker, Amy; ElSohly, Mahmoud A; Gul, Waseem; Hage, Raymond J; Hamann, Curtis P; Marks, James G

    Poison ivy, poison oak, and poison sumac are the most common causes of allergic contact dermatitis in North America. Although extensive efforts have been made to develop therapies that prevent and treat allergic contact dermatitis to these plants, there lacks an entirely effective method, besides complete avoidance. Efforts to develop a more effective preventive therapy, such as a vaccine, are ongoing. To accurately evaluate the efficacy of these new therapies, an appropriate assessment tool is needed. The aim of this study was to evaluate the safety and appropriate doses of urushiol required for a patch test based on the hydrogel delivery system of the Thin-Layer Rapid Use Epicutaneous Patch Test. Nine subjects were patch tested with various doses of urushiol and a negative control on day 0. Patch test sites were inspected for any local reaction on days 2, 4, 7, 14, and 21 after the initial exposure and graded by standard morphology. All 9 subjects did not have any significant adverse effects. The urushiol patch test using the hydrogel delivery method demonstrated urushiol sensitivity. All doses of urushiol resulted in a local reaction, and severity of reactions was correlated with dosage of urushiol used in the patch test.

  15. Repeated Methamphetamine Administration Differentially Alters Fos Expression in Caudate-Putamen Patch and Matrix Compartments and Nucleus Accumbens

    PubMed Central

    Jedynak, Jakub P.; Cameron, Courtney M.; Robinson, Terry E.

    2012-01-01

    Background The repeated administration of psychostimulant drugs produces a persistent and long-lasting increase (“sensitization”) in their psychomotor effects, which is thought to be due to changes in the neural circuitry that mediate these behaviors. One index of neuronal activation used to identify brain regions altered by repeated exposure to drugs involves their ability to induce immediate early genes, such as c-fos. Numerous reports have demonstrated that past drug experience alters the ability of drugs to induce c-fos in the striatum, but very few have examined Fos protein expression in the two major compartments in the striatum—the so-called patch/striosome and matrix. Methodology/Principal Findings In the present study, we used immunohistochemistry to investigate the effects of pretreatment with methamphetamine on the ability of a subsequent methamphetamine challenge to induce Fos protein expression in the patch and matrix compartments of the dorsolateral and dorsomedial caudate-putamen and in the ventral striatum (nucleus accumbens). Animals pretreated with methamphetamine developed robust psychomotor sensitization. A methamphetamine challenge increased the number of Fos-positive cells in all areas of the dorsal and ventral striatum. However, methamphetamine challenge induced Fos expression in more cells in the patch than in the matrix compartment in the dorsolateral and dorsomedial caudate-putamen. Furthermore, past experience with methamphetamine increased the number of methamphetamine-induced Fos positive cells in the patch compartment of the dorsal caudate putamen, but not in the matrix or in the core or shell of the nucleus accumbens. Conclusions/Significance These data suggest that drug-induced alterations in the patch compartment of the dorsal caudate-putamen may preferentially contribute to some of the enduring changes in brain activity and behavior produced by repeated treatment with methamphetamine. PMID:22514626

  16. Pharmacokinetic properties and tolerability of rotigotine transdermal patch after repeated-dose application in healthy korean volunteers.

    PubMed

    Kim, Bo-Hyung; Yu, Kyung-Sang; Jang, In-Jin; Soo Lim, Kyoung; Kim, Jung-Ryul; Elshoff, Jan-Peer; Andreas, Jens-Otto; Braun, Marina; Cawello, Willi

    2015-04-01

    Rotigotine, a nonergolinic dopamine receptor agonist, is a once-daily transdermal patch developed for the treatment of Parkinson's disease and restless legs syndrome. The objective of the present study was to determine the pharmacokinetic characteristics and tolerability of rotigotine transdermal patch after repeated-dose application in healthy male and female Korean subjects. In this randomized, double-blind, placebo-controlled, repeated-dose study, subjects were randomly assigned to receive either rotigotine or placebo (ratio, 20 rotigotine to 4 placebo, per sex). Rotigotine patches were applied once daily at a dose of 2 mg/24 h on days 1 to 3, followed by 4 mg/24 h on days 4 to 6. Serial blood and urine samples were collected on days 1 to 9 for the determination of the concentrations of rotigotine and its metabolites. Tolerability was evaluated by adverse events determined using physical examination, including vital signs with orthostatic measurements; ECG; and clinical laboratory testing. A total of 48 healthy Korean subjects were enrolled (24 men, 24 women; mean age, 24 years). Approximately 50% of the total drug content was delivered within 24 hours. The mean plasma concentration of unconjugated rotigotine increased proportionally with dose. At the 2 mg/24 h dose at steady state, the geometric mean AUC0-24h and Cmax values of unconjugated rotigotine were 5.88 ng·h/mL and 0.347 ng/mL, respectively; at the 4 mg/24 h dose, the corresponding values were 13.74 ng·h/mL and 0.838 ng/mL. The mean t½ of rotigotine was 4.96 hours. At the 2 mg/24 h dose at steady state, the geometric mean AUC0-24h and Cmax values of total rotigotine were 14.02 ng·h/mL and 0.776 ng/mL; at the 4-mg/24 h dose, 32.38 ng·h/mL and 1.867 ng/mL. Common adverse events reported in the rotigotine-treated subjects included nausea (17 subjects, 42.5%), headache (11, 27.5%), and dizziness (9, 22.5%). No clinically significant changes in blood pressure, ECG, or laboratory values were observed

  17. Patch testing in non-immediate cutaneous adverse drug reactions: value of extemporaneous patch tests.

    PubMed

    Assier, Haudrey; Valeyrie-Allanore, Laurence; Gener, Gwendeline; Verlinde Carvalh, Muriel; Chosidow, Olivier; Wolkenstein, Pierre

    2017-11-01

    Patch testing following a standardized protocol is reliable for identifying the culprit drug in cutaneous adverse drug reactions (CADRs). However, these patch tests (PTs) require pharmaceutical material and staff, which are not always easily available. To evaluate an extemporaneous PT method in CADRs. We retrospectively analysed data for all patients referred to our department between March 2009 and June 2013 for patch testing after a non-immediate CADR. The patients who supplied their own suspected drugs were tested both with extemporaneous PTs and with conventional PTs. Extemporaneous PTs involved a nurse crushing and diluting the drug in pet. in a ratio of approximately one-third to two-thirds. Standardized PTs were performed according to guidelines, with commercial drugs diluted to 30% or with active ingredients diluted to 10%. We analysed the data for the two PT methods in terms of the number of positive test reactions, drugs tested, and type of CADR for patients in whom the two PT methods were used. In total, 75 of 156 patients underwent the two PT procedures, including 91 double tests. Overall, 21 tests gave positive reactions with the two methods, and 69 other tests gave negative results with the two methods. Our series yielded results similar to those of published series concerning the types of CADR and the drugs responsible. Our results suggest that, for CADRs, if a patient supplies a suspected drug but if the pharmaceutical material and staff are not available for conventional PTs, extemporaneous PTs performed by the nurse with the commercial drug used by the patient can be useful and reliable. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Our experience with atopy patch tests with aeroallergens.

    PubMed

    Celakovská, Jarmila; Ettlerová, Kvetuse; Ettler, Karel; Vanecková, Jaroslava

    2013-01-01

    Aim of our study was to evaluate the importance of atopy patch testing with aeroallergens as a diagnostic method in patients suffering from atopic dermatitis. The complet dermatological and allergological examinations were performed in 29 patients; 10 men, 19 women with the average age of 27.8 years, min. 17, max. 57 years; with the median SCORAD 24.2 points, s.d. 13.3 points. Wormwood, grass, dog dander, cat dander, dermatophagoides pharinae, dermatophagoides pteronyssinus and birch pollen were examined in diagnostic procedures. Skin prick tests, specific IgE were examined; the atopy patch tests were performed with aeroallergens for skin prick tests in concentration 1 x skin prick tests. Specific IgE and skin prick tests to one or more tested aeroallergens were positive altogether in 27 patients; atopy patch tests were positive only in one of these patients. For atopy patch testing with aeroallergens the concentration of 1 x skin prick tests is low to confirme the eczematic reaction in patients suffering from allergy to inhallant allergens.

  19. A hydrogel pericardial patch.

    PubMed

    Allder, M A; Guilbeau, E J; Brandon, T A; Walker, A S; Koeneman, J B; Fisk, R L

    1990-01-01

    Patients undergoing repeat cardiac operations are higher operative risks than those undergoing an initial cardiac procedure because adhesion formation can occur if the native pericardium is not closed. A unique composite patch that may be used to augment the pericardial tissue when primary closure is not possible has been developed. The patch is made of a hydrogel, poly (2-hydroxyethyl methacrylate), reinforced with an ethylene tetrafluoroethylene (ETFE) mesh. The mesh provides the needed mechanical properties, whereas the patch's surface properties are comparable to the hydrogel. Two types of patches were fabricated: one with the mesh weave at a perpendicular orientation and one at 45 degrees to the principle loading direction. The patches were mechanically tested and compared with canine pericardium. Ultimate tensile strength of the patches is not significantly different from canine pericardium (p less than 0.05), are the patch suture strength is nearly twice that of canine pericardium. The perpendicular patch is stiffer than canine pericardium, whereas the 45 degree patch is not (p less than 0.05). The 45 degree patch shows considerable promise as a pericardial substitute because it closely matches the properties native canine pericardium.

  20. Patch-test reactions to plastic and glue allergens.

    PubMed

    Kanerva, L; Jolanki, R; Alanko, K; Estlander, T

    1999-07-01

    Plastics and glues are common causes of occupational dermatoses, but only few reports have dealt with patch-test reactions caused by plastic and glue allergens. Patients exposed to plastics and remitted to an occupational dermatology clinic, were patch-tested with 50-53 plastic and glue allergens during a 6-year period. Conventional patch-test techniques were used. The most common causes of allergic patch-test reactions in 360 patients were novolac epoxy resin (5.1%), phenol formaldehyde resin (3.1%), 4-tert-butylcatechol (2.6%), phenyl glycidyl ether (2.6%), diaminodiphenyl methane (2.2%), benzoyl peroxide (2.2%), hexamethylene tetramine (2.0%) and o-cresyl glycidyl ether (1.6%). The allergens that most often elicited irritant patch-test reactions were: benzoyl peroxide (9.5%), abitol alcohol (3.6%), hydroquinone (3.1%), acid-catalyzed phenol formaldehyde resin (2.5%) and toluene diisocyanate (1.9%). Twenty-six out of 53 chemicals caused no allergic reaction during the 6-year period. Plastic allergens in the standard series provoked allergic reactions with formaldehyde (5.8%), diglycidyl ether of bisphenol A (3.2%), 4-tert-butylphenol-formaldehyde-resin (1.1%), toluene sulphonamide formaldehyde-resin (1.1%) and triethylenglycol diacrylate (0.4%). Although half of the plastic chemicals gave no allergic patch-test reactions during a 6-year period, with unusual allergens this low yield needs to be accepted, because otherwise rare allergies will not be detected. Also a negative reaction has diagnostic value.

  1. Experimental patch testing with chromium-coated materials.

    PubMed

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D

    2017-06-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10 chromium-allergic patients, and 5 patients without chromium allergy. All were patch tested with potassium dichromate, cobalt chloride, nickel sulfate, and nine different metallic discs. The chromium-allergic patients were also patch tested with serial dilutions of potassium dichromate. Positive/weaker reactions were observed to disc B (1 of 10), disc C (1 of 10), and disc D, disc E, and disc I (4 of 10 each). As no controls reacted to any of the discs, the weak reactions indicate allergic reactions. Positive patch test reactions to 1770 ppm chromium(VI) in the serial dilutions of potassium dichromate were observed in 7 of 10 patients. When the case group was narrowed down to include only the patients with a current positive patch test reaction to potassium dichromate, elicitation of dermatitis by both chromium(III) and chromium(VI) discs was observed in 4 of 7 of patients. Many of the patients reacted to both chromium(III) and chromium(VI) surfaces. Our results indicate that both chromium(VI) and chromium(III) pose a risk to chromium-allergic patients. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Results of patch testing in 10 patients with peristomal dermatitis.

    PubMed

    Landis, Megan N; Keeling, James H; Yiannias, James A; Richardson, Donna M; Nordberg Linehan, Diane L; Davis, Mark D P

    2012-09-01

    Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis. We sought to describe our patch testing experience with patients referred with peristomal dermatitis. This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010). Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients). Retrospective nature of study via chart review is a limitation. Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Patch testing: facts and controversies.

    PubMed

    Wolf, Ronni; Orion, Edith; Ruocco, Vincenzo; Baroni, Adone; Ruocco, Eleonora

    2013-01-01

    The German dermatologist, Josef Jadassohn (1863-1936), first presented the results of his innovative patch-testing technique in 1895. The safety and efficacy of this diagnostic tool has stood the test of time and is still the gold standard for the diagnosis of allergic contact dermatitis (ACD). Since its discovery, much effort has been put into standardization and optimization of allergens, vehicles, and concentrations of patch-test materials; in procedures of its application; and in reading and scoring of test reactions--all contributing to the development of an accurate, reliable, and safe test with a high reproducibility of its results. Even this seemingly carved-in-stone practice, which has been used for nearly 120 years, has been questioned and challenged, engendering debates, disagreements, and controversies, which show no signs of coming to an end. Almost every step of the procedure has provoked discussions and controversies: Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Food patch testing for irritable bowel syndrome.

    PubMed

    Stierstorfer, Michael B; Sha, Christopher T; Sasson, Marvin

    2013-03-01

    The traditional classification of irritable bowel syndrome (IBS) as a functional disorder has been challenged in recent years by evidence of ongoing low-grade gastrointestinal tract inflammation. Inflammation may alter gastrointestinal motility and thus be central to the pathogenesis of IBS. Many foods and food additives are known to cause allergic contact dermatitis. We hypothesize that allergenic foods and food additives may elicit a similar allergic reaction in the gastrointestinal tract, giving rise to symptoms suggestive of IBS. We sought to determine whether skin patch testing to a panel of foods and food additives may identify food allergens that may be responsible for symptoms of IBS. We performed skin patch testing to common allergenic foods and food additives on individuals with a history of or symptoms suggestive of IBS. We used patch test-guided avoidance diets to determine whether avoidance alleviates IBS symptoms. Thirty of the 51 study participants showed at least 1 doubtful or positive patch test result. Fourteen of the participants reported symptomatic improvement, ranging from slight to great, upon avoidance of the foods/food additives to which they reacted. Double-blind study design, inclusion of only patients with active IBS, larger sample size, more balanced gender distribution, testing of more foods/food additives, and longer duration of and more precise quantification of response to dietary avoidance are suggested for future studies. Allergic contact enteritis to ingested foods, food additives, or both may contribute to IBS symptoms. Patch testing may be useful in identifying the causative foods. Copyright © 2012 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  5. Patch tests with fragrance materials and preservatives.

    PubMed

    de Groot, A C; Liem, D H; Nater, J P; van Ketel, W G

    1985-02-01

    179 patients suspected of cosmetic allergy were patch tested with a series of 16 fragrance materials and 9 preservatives. In 67 patients (37.4%), 1 or more of these substances gave positive reactions. In the group of fragrance materials, the largest numbers of positive patch test reactions were seen to isoeugenol, oak moss, geraniol, alpha-amylcinnamic alcohol, and a mixture of alpha-amylcinnamic aldehyde and alpha-hexylcinnamic aldehyde. The fragrance mix in the ICDRG standard series detected nearly 80% of cases of contact allergy to fragrance materials other than its constituents. In the group of preservatives, Kathon CG and quaternium-15 scored the highest number of positive reactions. It is argued that the commonly used patch test concentrations of 2% for oak moss and geraniol may be too low to detect all cases of sensitization.

  6. Patch testing custom isocyanate materials from the workplace.

    PubMed

    Burrows, Dianne; Houle, Marie-Claude; Holness, D Linn; DeKoven, Joel; Skotnicki, Sandy

    2015-01-01

    Patch testing with standard trays of commercially available allergens is the current practice for investigating suspected cases of isocyanate-induced allergic contact dermatitis (ACD). In some facilities, these standard trays are further supplemented with custom preparations of isocyanate-containing materials. The aim was to determine whether added value exists in patch testing patients to custom isocyanate preparations in suspected cases of ACD. We performed a retrospective analysis of 11 patients referred to our specialty clinic between January 2003 and March 2011 for suspected patients of ACD who had custom testing with isocyanate materials from their workplace. In addition to standard trays of allergens, all patients were patch tested with custom isocyanate materials from their workplaces. Three (27%) of 11 patients showed an added value in testing to custom isocyanate allergens. Of these 3 patients, one had a reaction that reinforced positive reactions to the standard isocyanate tray, but the other 2 (18%) had no reactions to any of the commercially available allergens. Because of the high proportion of reactions (27%), we recommend the use of custom testing to workplace isocyanate products as a supplement to current standard patch testing procedures.

  7. Variation in aluminium patch test reactivity over time.

    PubMed

    Siemund, Ingrid; Mowitz, Martin; Zimerson, Erik; Bruze, Magnus; Hindsén, Monica

    2017-11-01

    Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting. To investigate possible variations in patch test reactivity to aluminium over time. Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months. Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared. The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Flu Vaccine Skin Patch Tested

    MedlinePlus

    ... Subscribe September 2017 Print this issue Health Capsule Flu Vaccine Skin Patch Tested En español Send us ... Each year, millions of people nationwide catch the flu. The best way to protect yourself is to ...

  9. Utility of patch testing for patients with drug eruption.

    PubMed

    Ohtoshi, S; Kitami, Y; Sueki, H; Nakada, T

    2014-04-01

    Patch testing is less dangerous than oral provocation testing for identification of the causative drug for patients with drug eruption; however, its usefulness for such identification is controversial. To clarify the rates of positive patch testing for patients with drug eruption, classified by causative drugs and clinical features. We analysed results during the period 1990-2010 for 444 patients (151 men, 293 women; mean ± SD age 49.9 ± 18.6 years) who were tested for drug eruption. In the patient group, there were 309 people (69.1%) with maculopapular eruption and 31 (6.9%) with severe drug eruption. The test materials were applied to the back and left for 2 days under occlusion, then results were assessed by the International Contact Dermatitis Research Group (ICDRG) scoring system 3 days after application. Reactions of + to +++ were regarded as positive. Of the 444 patients, 100 (22.4%) had a positive patch test result to a suspected drug. Positive rates were 23.6% and 20.0% for maculopapular eruption and fixed drug eruption, respectively. The class of materials to which most patients reacted positively was contrast medium (n = 53; 41.1%), followed by drugs acting on the central nervous system (n = 18; 28.6%). In the latter group, 16 of the 18 patients were positive to antiepileptics. Positive rates depend on the causative drug rather than the clinical features of the drug eruption. Patch testing is useful when contrast medium or antiepileptics are suspected to be the causative drugs. However, standardization of patch test materials and method of reading is needed, as well as guidelines regarding when testing should be performed. Although patch testing for drug eruption has significant potential, it requires further validation. © 2014 The Authors. Clinical and Experimental Dermatology published by John Wiley & Sons Ltd on behalf of British Association of Dermatologists.

  10. Volatility of fragrance chemicals: patch testing implications.

    PubMed

    Gilpin, Sarah J; Hui, Xiaoying; Maibach, Howard I

    2009-01-01

    Diagnostic and predictive patch testing to determine contact allergy due to fragrance materials requires applying a fixed dose of material to the skin. This dose can be affected by the volatile nature of fragrances; little data exist on how the loss of fragrance dose due to volatility affects patch testing. (1) To evaluate pH dependence and evaporation rates of two fragrance chemicals, geraniol, citronellol, and a common fragrance solvent, diethyl phthalate (DEP) and (2) Assess implications for predictive patch-testing methods for fragrances. pH analysis of each material at 1% for three values (4.0, 5.0, 7.0) was done over 40 hours. Volatility experiments for each material, nonradiolabeled and radiolabeled, were conducted over a 24-hour period, taking readings at six time points (5 minutes, 15 minutes, 40 minutes, 1 hour, 3 hours, and 24 hours). Evaporation rates were not sensitive to pH shifts from 4.0 to 7.0. Evaporation rates for nonradiolabeled materials were low: after 24 hours, geraniol lost 8.9%, citronellol 27.0% and DEP 14.5%. The volatility data for radiolabeled materials demonstrated that geraniol loses up to 39% of its dose, citronellol loses up to 26%, and DEP up to 14% within 40 minutes. The tendency of fragrance materials to evaporate can impact the dose being applied to the patch and therefore the result of the patch and ultimately the decision-making process regarding that fragrance material's safety. These data, developed with DEP, utilized in a predictive sensitization assay cannot be generalized.

  11. [Patch testing: historical aspects].

    PubMed

    Lachapelle, J-M

    2009-01-01

    This article reviews the key points in the history of patch testing, which spans more than a century, starting with the first description of the method by J. Jadassohn in 1895. Special attention is paid to the contribution of French schools in this field, which led to the foundation of the Groupe d'études et de recherches en dermato-allergologie (GERDA).

  12. Limonene hydroperoxide analogues show specific patch test reactions.

    PubMed

    Christensson, Johanna Bråred; Hellsén, Staffan; Börje, Anna; Karlberg, Ann-Therese

    2014-05-01

    The fragrance terpene R-limonene is a very weak sensitizer, but forms allergenic oxidation products upon contact with air. The primary oxidation products of oxidized limonene, the hydroperoxides, have an important impact on the sensitizing potency of the oxidation mixture. One analogue, limonene-1-hydroperoxide, was experimentally shown to be a significantly more potent sensitizer than limonene-2-hydroperoxide in the local lymph node assay with non-pooled lymph nodes. To investigate the pattern of reactivity among consecutive dermatitis patients to two structurally closely related limonene hydroperoxides, limonene-1-hydroperoxide and limonene-2-hydroperoxide. Limonene-1-hydroperoxide, limonene-2-hydroperoxide, at 0.5% in petrolatum, and oxidized limonene 3.0% pet. were tested in 763 consecutive dermatitis patients. Of the tested materials, limonene-1-hydroperoxide gave most reactions, with 2.4% of the patients showing positive patch test reactions. Limonene-2-hydroperoxide and oxidized R-limonene gave 1.7% and 1.2% positive patch test reactions, respectively. Concomitant positive patch test reactions to other fragrance markers in the baseline series were frequently noted. The results are in accordance with the experimental studies, as limonene-1-hydroperoxide gave more positive patch test reactions in the tested patients than limonene-2-hydroperoxide. Furthermore, the results support the specificity of the allergenic activity of the limonene hydroperoxide analogues and the importance of oxidized limonene as a cause of contact allergy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Atopy patch test reactions to house dust mites in patients with scabies.

    PubMed

    Taşkapan, Oktay; Harmanyeri, Yavuz

    2005-01-01

    It is well known that the house dust and the scabies mites are related phylogenetically. We therefore performed atopy patch tests with house dust mite antigens (Dermatophagoides pteronyssinus (Dp) and/or Dermatophagoides farinae (Df)) in scabies patients without atopy and healthy controls. We studied 25 men with active scabies and 25 healthy controls. Skin prick tests with standardized house dust mite extract were performed for all patients and controls. An intradermal test procedure was carried out in skin prick test-negative patients, and for controls showing positive atopy patch test to Dp and/or Df. While atopy patch tests were performed directly in all healthy controls, patients with scabies were first treated and on the next day, atopy patch tests were performed. Twenty-two of 25 patients with scabies (88%) had skin prick test and/or intradermal test positivity against house dust mites, whereas 17/25 patients (68%) had atopy patch test positivity against house dust mites (Dp and/or Df). There was no statistically significant difference between skin prick test and/or intradermal test positivity and atopy patch test positivity in a regression analysis (p=0.222). The only statistically significant correlation was between atopy patch test positivity and the extent of scabies involvement (p<0.05). Only few of the healthy controls had positive tests. In this study, we have shown that a positive atopy patch test to house dust mite antigens is not specific for patients with atopic dermatitis, but also occurs in scabies patients without a history of atopic dermatitis.

  14. Results of patch testing with lavender oil in Japan.

    PubMed

    Sugiura, M; Hayakawa, R; Kato, Y; Sugiura, K; Hashimoto, R

    2000-09-01

    We report the annual results of patch testing with lavender oil for a 9-year period from 1990 to 1998 in Japan. Using Finn Chambers and Scanpor tape, we performed 2-day closed patch testing with lavender oil 20% pet. on the upper back of each patient suspected of having cosmetic contact dermatitis. We compared the frequency of positive patch tests to lavender oil each year with those to other fragrances. We diagnosed contact allergy when patch test reactions were + or <+ at 1 day after removal. The positivity rate of lavender oil was 3.7% (0-13.9%) during the 9-year period from 1990 to 1998. The positivity rate of lavender oil increased suddenly in 1997. Recently, in Japan, there has been a trend for aromatherapy using lavender oil. With this trend, placing dried lavender flowers in pillows, drawers, cabinets, or rooms has become a new fashion. We asked patients who showed a positive reaction to lavender oil about their use of dried lavender flowers. We confirmed the use of dried lavender flowers in 5 cases out of 11 positive cases in 1997 and 8 out of 15 positive cases in 1998. We concluded that the increase in patch test positivity rates to lavender oil in 1997 and 1998 was due to the above fashion, rather than due to fragrances in cosmetic products.

  15. Membrane Vibration Tests Using Surface-Bonded Piezoelectric Patch Actuation

    NASA Technical Reports Server (NTRS)

    Gasper, James L.; Pappa, Richard S.

    2003-01-01

    This paper describes the status of on-going work at the NASA Langley Research Center to measure the dynamics of thin membranes. The test article is a one-meter square pre-tensioned Kapton membrane that incorporates small surface-bonded piezoelectric patches strategically positioned to excite many modes. It is shown that PVDF (polyvinylidene fluoride) and MFC (macro fiber composite) piezoelectric patch actuators provide adequate excitation energy to obtain modal frequencies and mode shapes. Results from modal tests performed on the membrane using piezoelectric patches of different sizes and positions are discussed.

  16. Evaluation and Management of Patch Test-Negative Patients With Generalized Dermatitis.

    PubMed

    Spiker, Alison; Mowad, Christen M

    Patients with generalized dermatitis are common in dermatology practices. Allergic contact dermatitis is often suspected, and patients frequently undergo patch testing. When the patch testing result is negative, further evaluation and management of these patients are challenging. The purpose of this study was to survey members of the American Contact Dermatitis Society regarding the evaluation and management of patch test-negative patients with generalized dermatitis. Generalized dermatitis was the most common term identified for patch test-negative patients with diffuse dermatitis. After having negative expanded patch testing results, most physicians proceeded with additional testing including skin biopsy, complete blood cell count with differential, and liver and renal function tests. The most commonly used systemic treatment is prednisone, followed by methotrexate. Narrow-band ultraviolet B (UVB) is the most commonly used light source. Antihistamines are frequently prescribed. Food allergy is not felt to be causative. This cohort of patients experiences significant impairment in quality of life, stress on personal relationships, and time off work. The management of patch test-negative patients with generalized dermatitis is challenging. This study provides insight into management of these complex patients. It also demonstrates practice gaps in the management of these patients, indicating a need for further studies to direct the evaluation and management of this patient population.

  17. Evaluation of modifications of the traditional patch test in assessing the chemical irritation potential of feminine hygiene products.

    PubMed

    Farage, Miranda A; Meyer, Sandy; Walter, Dave

    2004-05-01

    The first main objective of the work presented in this paper was to investigate ways of optimizing the current arm patch test protocol by (1) increasing the sensitivity of the test in order to evaluate more effectively the products that are inherently non-irritating, and/or (2) reducing the costs of these types of studies by shortening the protocol. The second main objective was to use the results of these studies and the results of the parallel studies conducted using the behind-the-knee method to better understand the contribution of mechanical irritation to the skin effects produced by these types of products. In addition, we were interested in continuing the evaluation of sensory effects and their relationship to objective measures of irritation. Test materials were prepared from three, currently marketed feminine protection pads. Wet and dry samples were applied to the upper arm using the standard 24-h patch test. Applications were repeated daily for 4 consecutive days. The test sites were scored for irritation prior to the first patch application, and 30-60 min after removal of each patch. Some test sites were treated by tape stripping the skin prior to the initial patch application. In addition, in one experiment, panelists were asked to keep a daily diary describing any sensory skin effects they noticed at each test site. All protocol variations ([intact skin/dry samples], [compromised skin/dry samples], [intact skin/wet samples], and [compromised skin/wet samples]) gave similar results for the products tested. When compared to the behind-the-knee test method, the standard upper arm patch test gave consistently lower levels of irritation when the test sites were scored shortly after patch removal, even though the sample application was longer (24 vs. 6 h) in the standard patch test. The higher level of irritation in the behind-the-knee method was likely due to mechanical irritation. The sensory skin effects did not appear to be related to a particular test

  18. Childhood Brain Insult: Can Age at Insult Help Us Predict Outcome?

    ERIC Educational Resources Information Center

    Anderson, Vicki; Spencer-Smith, Megan; Leventer, Rick; Coleman, Lee; Anderson, Peter; Williams, Jackie; Greenham, Mardee; Jacobs, Rani

    2009-01-01

    Until recently, the impact of early brain insult (EBI) has been considered to be less significant than for later brain injuries, consistent with the notion that the young brain is more flexible and able to reorganize in the context of brain insult. This study aimed to evaluate this notion by comparing cognitive and behavioural outcomes for…

  19. Patch-test reaction patterns in patients with a predisposition to atopic dermatitis.

    PubMed

    Brasch, Jochen; Schnuch, Axel; Uter, Wolfgang

    2003-10-01

    Patients with a predisposition to atopic dermatitis often need to be patch tested in order to detect possible contact sensitization. However, it is unknown whether immunologic or other peculiarities of atopic skin are related to altered patch-test reaction patterns. Our study was aimed at answering this question, because patch-test reaction patterns are of considerable practical importance in the reading and interpretation of patch tests. Therefore, we compared patterns of patch-test reactions in patients with a predisposition to atopic dermatitis and in control patients matched for sex, age, reason for testing and test centre. Patch-test results from 9 centres (2322 patients with a disposition to atopic dermatitis and 2126 matched controls) were evaluated retrospectively. All patients were tested with nickel sulfate, fragrance mix, potassium dichromate, lanolin alcohol, formaldehyde and mercury ammonium chloride. Patch tests applied for 1 day with readings on days 1, 2 and 3 were evaluated in order to cover the early phase of the reactions. Not unexpectedly, we found that, compared to the matched controls, patients with a predisposition to atopic dermatitis tended to have more doubtful and irritant reactions on day 1. As a new observation, it turned out that they had less reactions of crescendo pattern and more strong reactions on day 3. All these differences were slight/insignificant. A higher skin irritability in patients with a predisposition to atopic dermatitis is a likely explanation. In conclusion, standard methods for patch testing can be applied in patients with a predisposition to atopic dermatitis, but minor differences in reaction patterns should be considered.

  20. Nevirapine patch testing in Thai human immunodeficiency virus infected patients with nevirapine drug hypersensitivity.

    PubMed

    Prasertvit, Piyatida; Chareonyingwattana, Angkana; Wattanakrai, Penpun

    2017-12-01

    Antiretroviral drug hypersensitivity in HIV patients is common. Publications have shown that Abacavir (ABC) patch testing is useful in confirming ABC hypersensitivity in 24-50% of cases with a 100% sensitivity of HLA-B*5701 in patch test positive cases. However, Nevirapine (NVP) patch testing has not been reported. (1) To evaluate the usefulness and safety of NVP patch testing in Thai HIV patients with NVP hypersensitivity. (2) To assess the correlation of positive patch tests with HLA-B*3505. Patients were classified into two groups: (1) study group of 20 HIV NVP hypersensitivity patients and (2) control group of 15 volunteers without NVP hypersensitivity. Both groups were patch tested with purified and commercialized form of NVP in various vehicles. Two HIV patients with NVP hypersensitivity were patch test positive. All controls tested negative. Three HIV patients were positive for HLA-B*3505 and the two patients with positive patch testing were both HLA-B*3505 positive. NVP patch testing in Thai HIV patients is safe and can be used to help confirm the association between NVP and hypersensitivity skin reactions. NVP patch test results significantly correlated with HLA-B*3505. The sensitivity of HLA-B*3505 for positive patch test was 100%. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Cinnamic aldehyde: a survey of consumer patch-test sensitization.

    PubMed

    Danneman, P J; Booman, K A; Dorsky, J; Kohrman, K A; Rothenstein, A S; Sedlak, R I; Steltenkamp, R J; Thompson, G R

    1983-12-01

    The potential for cinnamic aldehyde, an important fragrance and flavour ingredient, to induce or to elicit delayed contact hypersensitivity reactions in man was evaluated by analysing patch-test data. Results of studies involving a total of 4117 patch tests on various consumer products and fragrance blends containing cinnamic aldehyde and on the material itself were collected from fragrance and formulator companies. The data indicate that cinnamic aldehyde contained in consumer products and fragrance blends at concentrations up to 6 X 10(-1)%, and patch-tested at concentrations up to 8 X 10(-3)%, has no detectable potential to induce hypersensitivity. Cinnamic aldehyde when tested alone induced a dose-related hypersensitivity response. According to published reports, cinnamic aldehyde elicited positive delayed hypersensitivity responses in dermatitic patients. However, results of the current survey show that when cinnamic aldehyde was tested alone or as part of a mixture in subjects in the general population, no pre-existing hypersensitivity reactions to the fragrance material were observed in any of the 4117 patch tests which constituted the survey. Cinnamic aldehyde at the concentrations contained in consumer products and fragrances, has a very low potential to induce hypersensitivity ('induced' reactions) or to elicit sensitization reactions ('elicited' reactions) in the general population.

  2. Investigation of contact allergy to dental materials by patch testing.

    PubMed

    Rai, Reena; Dinakar, Devina; Kurian, Swetha S; Bindoo, Y A

    2014-07-01

    Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG). Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials.

  3. Stability of fragrance patch test preparations applied in test chambers.

    PubMed

    Mowitz, M; Zimerson, E; Svedman, C; Bruze, M

    2012-10-01

    Petrolatum patch test preparations are for practical reasons often applied in test chambers in advance, several hours or even days before the patient is tested. As many fragrance compounds are volatile it may be suspected that petrolatum preparations applied in test chambers are not stable over time. To investigate the stability of petrolatum preparations of the seven chemically defined components in the fragrance mix (FM I) when stored in test chambers. Samples of petrolatum preparations applied in test chambers stored at room temperature and in a refrigerator for between 4 and 144 h were analysed using liquid chromatographic methods. The concentration decreased by ≥ 20% within 8 h in four of seven preparations stored in Finn chambers at room temperature. When stored in a refrigerator only the preparation of cinnamal had decreased by ≥ 20% within 24 h. The stability of preparations of cinnamal stored in IQ chambers with a plastic cover was slightly better, but like the preparations applied in Finn chambers, the concentration decreased by ≥ 20% within 4 h at room temperature and within 24 h in a refrigerator. Cinnamal and cinnamyl alcohol were found to be more stable when analysed as ingredients in FM I compared with when analysed in individual preparations. Within a couple of hours several fragrance allergens evaporate from test chambers to an extent that may affect the outcome of the patch test. Application to the test chambers should be performed as close to the patch test occasion as possible and storage in a refrigerator is recommended. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.

  4. Investigation of contact allergy to dental materials by patch testing

    PubMed Central

    Rai, Reena; Dinakar, Devina; Kurian, Swetha S.; Bindoo, Y. A.

    2014-01-01

    Background: Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. Aim: This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Materials and Methods: Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG). Results: Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. Conclusion: The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials. PMID:25165644

  5. Is a specific eyelid patch test series useful? Results of a French prospective study.

    PubMed

    Assier, Haudrey; Tetart, Florence; Avenel-Audran, Martine; Barbaud, Annick; Ferrier-le Bouëdec, Marie-Christine; Giordano-Labadie, Françoise; Milpied, Brigitte; Amsler, Emmanuelle; Collet, Evelyne; Girardin, Pascal; Soria, Angèle; Waton, Julie; Truchetet, François; Bourrain, Jean-Luc; Gener, Gwendeline; Bernier, Claire; Raison-Peyron, Nadia

    2018-06-08

    Eyelids are frequent sites of contact dermatitis. No prospective study focused on eyelid allergic contact dermatitis (EACD) has yet been published, and this topic has never been studied in French patients. To prospectively evaluate the usefulness of an eyelid series in French patients patch tested because of EACD, and to describe these patients. We prospectively analysed standardized data for all patients referred to our departments between September 2014 and August 2016 for patch testing for suspected EACD as the main reason. All patients were patch tested with an eyelid series, the European baseline series (EBS), the French additional series, and their personal products. Patch testing with additional series and repeated open application tests (ROATs) or open tests were performed if necessary. A standardized assessment of the relevance was used, and the analysis of the results was focused on patients having positive test results with a current certain relevance. Two-hundred and sixty-four patients (238 women and 26 men) were included. Three-hundred and twenty-two tests gave positive results in 167 patients, 84 of whom had currently relevant reactions: 56 had currently relevant positive test reactions to the EBS, 16 had currently relevant positive test reactions to their personal products, 8 had currently relevant positive test reactions to the French additional series, and 4 had currently relevant positive test reactions to the eyelid series. Sixty-seven per cent of all relevant cases were related to cosmetic products. The most frequent allergens with current relevance were methylisothiazolinone (10.2%), fragrance mix I (3%), nickel (2.7%), hydroxyperoxides of linalool (2.7%) and limonene (2.3%), and Myroxylon pereirae (2.3%). Current atopic dermatitis was found in 9.5% of patients. The duration of dermatitis was shorter (23.2 vs 34.2 months; P = .035) in patients with currently relevant test reactions. The percentage of currently relevant tests remained the

  6. A review of 241 subjects who were patch tested twice: could fragrance mix I cause active sensitization?

    PubMed

    White, J M L; McFadden, J P; White, I R

    2008-03-01

    Active patch test sensitization is an uncommon phenomenon which may have undesirable consequences for those undergoing this gold-standard investigation for contact allergy. To perform a retrospective analysis of the results of 241 subjects who were patch tested twice in a monocentre evaluating approximately 1500 subjects per year. Positivity to 11 common allergens in the recommended Baseline Series of contact allergens (European) was analysed: nickel sulphate; Myroxylon pereirae; fragrance mix I; para-phenylenediamine; colophonium; epoxy resin; neomycin; quaternium-15; thiuram mix; sesquiterpene lactone mix; and para-tert-butylphenol resin. Only fragrance mix I gave a statistically significant, increased rate of positivity on the second reading compared with the first (P=0.011). This trend was maintained when separately analysing a subgroup of 42 subjects who had been repeat patch tested within 1 year; this analysis was done to minimize the potential confounding factor of increased usage of fragrances with a wide interval between both tests. To reduce the confounding effect of age on our data, we calculated expected frequencies of positivity to fragrance mix I based on previously published data from our centre. This showed a marked excess of observed cases over predicted ones, particularly in women in the age range 40-60 years. We suspect that active sensitization to fragrance mix I may occur. Similar published analysis from another large group using standard methodology supports our data.

  7. Finding the optimal patch test material and test concentration to detect contact allergy to geraniol.

    PubMed

    Hagvall, Lina; Karlberg, Ann-Therese; Christensson, Johanna B

    2013-04-01

    Geraniol is a commonly used fragrance terpene, and is tested in the baseline series in fragrance mix I. Geraniol is a pro-hapten and a pre-hapten, and sensitizers are formed in the autoxidation and skin metabolism of geraniol. Previous patch testing with air-exposed (oxidized) geraniol has suggested that oxidized geraniol could be a better marker for contact allergy to geraniol than pure geraniol. To find the optimal patch test substance and concentration for detecting contact allergy to geraniol. Six hundred and fifty-five patients were patch tested with pure and oxidized geraniol at 4.0%, 6.0% and 11.0% in petrolatum. Before patch testing, the irritant properties of pure and oxidized geraniol were studied in 27 patients at 2.5%, 5.0%, 10.0% and 20.0% pet. Pure geraniol detected positive reactions in 0.15-1.1% of the patients, and oxidized geraniol detected positive reactions in 0.92-4.6% of the patients. Reactions to pure geraniol in patients not reacting to oxidized geraniol indicated metabolic activation of geraniol. Neither pure nor oxidized geraniol gave significant irritant reactions. Increasing the test concentrations of pure and oxidized geraniol enables the detection of more cases of contact allergy. Oxidized geraniol detects more patients than pure geraniol, but patch testing with only oxidized geraniol does not detect all cases of contact allergy to geraniol. © 2013 John Wiley & Sons A/S.

  8. Patch testing in children from 2005 to 2012: results from the North American contact dermatitis group.

    PubMed

    Zug, Kathryn A; Pham, Anh Khoa; Belsito, Donald V; DeKoven, Joel G; DeLeo, Vincent A; Fowler, Joseph F; Fransway, Anthony F; Maibach, Howard I; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Sasseville, Denis; Storrs, Frances J; Taylor, James S; Warshaw, Erin M; Zirwas, Matthew J

    2014-01-01

    Allergic contact dermatitis is common in children. Epicutaneous patch testing is an important tool for identifying responsible allergens. The objective of this study was to provide the patch test results from children (aged ≤18 years) examined by the North American Contact Dermatitis Group from 2005 to 2012. This is a retrospective analysis of children patch-tested with the North American Contact Dermatitis Group 65- or 70-allergen series. Frequencies and counts were compared with previously published data (2001-2004) using χ statistics. A total of 883 children were tested during the study period. A percentage of 62.3% had ≥1 positive patch test and 56.7% had ≥1 relevant positive patch test. Frequencies of positive patch test and relevant positive patch test reaction were highest with nickel sulfate (28.1/25.6), cobalt chloride (12.3/9.1), neomycin sulfate (7.1/6.6), balsam of Peru (5.7/5.5), and lanolin alcohol 50% petrolatum vehicle (5.5/5.1). The ≥1 positive patch test and ≥1 relevant positive patch test in the children did not differ significantly from adults (≥19 years) or from previously tested children (2001-2004). The percentage of clinically relevant positive patch tests for 27 allergens differed significantly between the children and adults. A total of 23.6% of children had a relevant positive reaction to at least 1 supplemental allergen. Differences in positive patch test and relevant positive patch test frequencies between children and adults as well as test periods confirm the importance of reporting periodic updates of patch testing in children to enhance clinicians' vigilance to clinically important allergens.

  9. Patch Testing in Patients with Suspected Footwear Dermatitis: A Retrospective Study.

    PubMed

    Garg, Taru; Agarwal, Soumya; Rana, Shiwangi; Chander, Ram

    2017-01-01

    Footwear dermatitis represents a common but often undiagnosed or misdiagnosed condition. Patch testing aids in its confirmation and identification of the offending allergen. This study aimed to find the frequency of positive patch test reactions in cases with suspected allergic contact dermatitis (ACD) to footwear, as well as the common responsible allergens. This is a retrospective record based study of 37 patients, with suspected ACD to footwear, who underwent patch testing with Indian standard series and Indian footwear series from July 2012 to July 2015. The majority of patients (45.94%) belonged to the age group of 20-40 years. Dorsal aspects of feet (81.08%) and soles (18.92%) were the common sites involved. Patch test was positive in 18.92% patients. The most common causative allergens were hydroquinone monobenzylether (8.11%) and 4-aminoazobenzene (5.41%). Common chemicals implicated in ACD were rubber, rubber additives, and dyes. The principal culprit allergens were hydroquinone monobenzylether and 4-aminoazobenzene.

  10. No laughing matter: How the presence of laughing witnesses changes the perception of insults.

    PubMed

    Otten, Marte; Mann, Liesbeth; van Berkum, Jos J A; Jonas, Kai J

    2017-04-01

    Insults always sting, but the context in which they are delivered can make the effects even worse. Here we test how the brain processes insults, and whether and how the neurocognitive processing of insults is changed by the presence of a laughing crowd. Event-related potentials showed that insults, compared to compliments, evoked an increase in N400 amplitude (indicating increased lexical-semantic processing) and LPP amplitude (indicating emotional processing) when presented in isolation. When insults were perceived in the presence of a laughing crowd, the difference in N400 amplitude disappeared, while the difference in LPP activation increased. These results show that even without laughter, verbal insults receive additional neural processing over compliments, both at the lexical-semantic and emotional level. The presence of a laughing crowd has a direct effect on the neurocognitive processing of insults, leading to stronger and more elongated emotional processing.

  11. Diagnostic accuracy of patch test in children with food allergy.

    PubMed

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Pediatric Baseline Patch Test Series: Initial Findings of the Pediatric Contact Dermatitis Workgroup.

    PubMed

    Yu, JiaDe; Atwater, Amber Reck; Brod, Bruce; Chen, Jennifer K; Chisolm, Sarah S; Cohen, David E; de la Feld, Salma; Gaspari, Anthony A; Martin, Kari Lyn; Montanez-Wiscovich, Marjorie; Sheehan, Michael; Silverberg, Nanette; Lugo-Somolinos, Aida; Thakur, Binod K; Watsky, Kalman; Jacob, Sharon E

    2018-06-21

    Allergic contact dermatitis is a challenging diagnostic problem in children. Although epicutaneous patch testing is the diagnostic standard for confirmation of contact sensitization, it is less used in children by dermatologists treating children, pediatric dermatologists, and pediatricians, when compared with adult practitioners. The aim of the study was to create and evaluate standardization of a pediatric patch test series for children older than 6 years. We surveyed dermatologists and allergists conducting epicutaneous patch testing in children attending the 2017 American Contact Dermatitis Society meeting held in Washington, DC. This was followed by discussion of collected data and consensus review by a pediatric contact dermatitis working group at the conference. A baseline pediatric patch test panel was established through working group consensus.

  13. Is there a risk of active sensitization to PPD by patch testing the general population?

    PubMed

    Thyssen, Jacob Pontoppidan; Menné, Torkil; Nielsen, Niels Henrik; Linneberg, Allan

    2007-08-01

    Para-phenylenediamine (PPD), a constituent of permanent hair dyes, may cause contact allergy in exposed individuals. It has previously been questioned whether a patch testing with PPD in population-based epidemiological studies is entirely safe. The Glostrup allergy studies patch tested the same cohort twice. In 1990, 567 persons were patch-tested and only one person had a (+) positive reaction to PPD. In 1998, 540 persons were re-invited to a new patch test and 365 (participation rate 68%) were re-tested. There were no positive reactions to PPD. These studies indicate that patch testing with PPD in individuals with no previous positive reactions to PPD or with only one previous positive reaction does not cause active sensitization and can be performed with minimal risk.

  14. Portable Holographic Interferometry Testing System: Application to crack patching quality control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.

    Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less

  15. A patch test confirmed phenobarbital-induced fixed drug eruption in a child.

    PubMed

    Chadly, Zohra; Aouam, Karim; Chaabane, Amel; Belhadjali, Hichem; Abderrazzak Boughattas, Naceur; Zili, Jamel Eddine

    2014-06-01

    A-10-year-old girl was referred to our department for multiple hyperpigmented plaques. One week previously, she had been given one suppository of acetylsalicylic acid - phenobarbital for fever. Twelve hours after the drug intake the child developed pruritic red plaques on the left thigh. Six weeks after resolution of the acute reaction, patch tests were performed separately, with phenobarbital and acetylsalicylic acid. On 48-hour reading, only the phenobarbital patch test on residual pigmented lesion was positive. Because of possible cross-reactions between aromatic anticonvulsants, subsequent patch tests using carbamazepine and phenytoin on residual pigmented lesions were performed. They were all negative at 48-hour reading. To our knowledge, only two isolated pediatric cases of Phenobarbital-induced FDE have been reported in the literature. In this case report, as it was difficult to determine whether phenobarbital or acetylsalicylic acid was responsible for this reaction, subsequent patch tests allowed the identification of the culprit component since it was positive to phenobarbital.

  16. Prevalence of benzocaine and lidocaine patch test sensitivity in Denmark: temporal trends and relevance.

    PubMed

    Thyssen, Jacob P; Engkilde, Kåre; Menné, Torkil; Johansen, Jeanne D

    2011-08-01

    BACKGROUND. Allergens included in the European baseline series should result in positive patch test reactions in at least 1% of a patch test population. Inclusion of local anaesthetics other than benzocaine in the baseline series has previously been debated. To investigate temporal trends of benzocaine and lidocaine allergy in dermatitis patients who underwent routine patch testing in a tertiary referral patch test centre, and to clarify and discuss whether lidocaine and benzocaine should be included in routine series. Dermatitis patients who underwent routine patch testing with benzocaine as a part of the European baseline series between 1985 and 2010 (n = 19 347) and dermatitis patients who underwent routine patch testing with lidocaine between 1994 and 2001 (n = 6265) and between 2007 and 2009 (n = 1360) were included. The overall prevalences of contact allergy were 0.5% (benzocaine), 0.3% (lidocaine for the period 1994-2001), and 0.14% (lidocaine for the period 2007-2009). Current relevance was observed in 10% of those with benzocaine allergy and in 5% of those with lidocaine allergy. Benzocaine and lidocaine allergy is infrequent in Danish dermatitis patients. Lidocaine should only be used for aimed testing, and benzocaine should be removed from the baseline series used in Denmark. © 2011 John Wiley & Sons A/S.

  17. Allergic contact dermatitis to benzocaine: the importance of concomitant positive patch test results.

    PubMed

    González-Rodríguez, A J; Gutiérrez-Paredes, E M; Revert Fernández, Á; Jordá-Cuevas, E

    2013-03-01

    Local anesthetics are widely used in clinical practice, and adverse effects are not uncommon. Delayed hypersensitivity reactions are among the most common effects, but immediate-type reactions may also occur. Patch testing should be considered in patients with hypersensitivity reactions. We present a case of allergic contact dermatitis to benzocaine that was detected incidentally by patch testing and highlight the importance of correctly interpreting patch test results when there are concomitant positive reactions. Copyright © 2011 Elsevier España, S.L. and AEDV. All rights reserved.

  18. Fragrance patch tests prepared in advance may give false-negative reactions.

    PubMed

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Bruze, Magnus

    2014-11-01

    Several of the ingredients in fragrance mix I (FM I) have been shown to evaporate from petrolatum preparations applied in test chambers to an extent that can be suspected to affect the patch test result. To compare the reactivity towards FM I and fragrance mix II (FM II) when they are applied in test chambers in advance and immediately prior to the patch test occasion. Seven hundred and ninety-five consecutive patients were simultaneously patch tested with duplicate samples of FM I and FM II. One sample was applied in the test chamber 6 days in advance (6D sample), and the other sample was applied immediately before the patients were patch tested (fresh sample). Twenty-two (2.8%) patients reacted exclusively to the fresh sample of FM I, 6 (0.7%) reacted exclusively to the 6D sample, and 22 (2.8%) reacted to both samples. The corresponding numbers for FM II were 9 (1.1%) for the fresh sample, 6 (0.7%) for the 6D sample and 12 (1.5%) for both samples. There was a statistically significant difference between the numbers of patients reacting to the fresh and 6D samples of FM I. No corresponding difference was observed for FM II. This can probably be explained by differences in volatilities between the ingredients of FM I and FM II. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Photo-patch and patch tests in patients with dermatitis over the photo-exposed areas: A study of 101 cases from a tertiary care centre in India.

    PubMed

    Sharma, Vinod Kumar; Bhari, Neetu; Wadhwani, Ashok Roopchand; Bhatia, Riti

    2018-02-01

    Many patients with dermatitis over photo-exposed body areas are positive to many contact allergens and have a pre-existing allergic contact dermatitis. This study included patients who presented to a tertiary centre in India with dermatitis on photo-exposed body areas suspected of chronic actinic dermatitis. Their detailed histories were recorded and cutaneous and systemic examinations were performed. Patch testing was done in all the patients and photo-patch testing was carried out in 86 patients. Altogether 101 patients were included (69 males, 32 females). The most common presentation was lichenified hyperpigmented plaques on the photo-exposed sites. Photosensitivity was recorded in 64 (63%) patients and summer exacerbation in 52 (52%). Exposure to the Parthenium hysterophorus weed was recorded in 70 (69%) patients, 27 (26.7%) had a history of hair dye application and 20 (20%) had a history of atopy. Photo-patch test was positive in 11 (12.8%) patients and patch testing was positive in 71 (70%). Parthenium hysterophorus was the most common allergen implicated and was positive in three (4%) photo-patch and 52 (52%) patch tests. Other positive photo-patch test allergens were perfume mix, balsam of Peru, thiuram mix, Compositae mix and promethazine hydrochloride. Other common patch test allergens were parthenolide, colophony, fragrance mix and p-phenylenediamine (PPD) base. In the Indian population parthenium and perfume mix are the most common photoallergens in patients with dermatitis over photo-exposed areas, while parthenium, colophony, fragrance mix and PPD are the common positive allergens. © 2016 The Australasian College of Dermatologists.

  20. Evaluation of canine adverse food reactions by patch testing with single proteins, single carbohydrates and commercial foods.

    PubMed

    Johansen, Cornelia; Mariani, Claire; Mueller, Ralf S

    2017-10-01

    Adverse food reaction (AFR) is an important differential diagnosis for the pruritic dog. It is usually diagnosed by feeding an elimination diet with a novel protein and carbohydrate source for eight weeks followed by subsequent food provocation. A previous study demonstrated that patch testing dogs with foods had a high sensitivity and negative predictability for selection of elimination diet ingredients. The aim of this study was to investigate patch testing with proteins, carbohydrates and dry commercial dog food in dogs to determine whether there was value in patch testing to aid the diagnosis of canine adverse food reaction. Twenty five privately owned dogs, with confirmed AFR, underwent provocation trials with selected food antigens and patch testing. For proteins, carbohydrates and dry dog food the sensitivity of patch testing was 100%, 70% and 22.2%, respectively; the negative predictive values of patch testing were 100%, 79% and 72%. The positive predictive values of patch testing for proteins and carbohydrates were 75% and 74%, respectively. This study confirmed that patch testing may be useful for the selection of a suitable protein source for an elimination diet in dogs with suspected AFR, but not as a diagnostic tool for canine AFR. Results for proteins are more reliable than for carbohydrates and the majority of positive patch test reactions were observed with raw protein. Patch testing with commercial dog food does not seem to be useful. © 2017 ESVD and ACVD.

  1. A Pragmatic Approach to Patch Testing Atopic Dermatitis Patients: Clinical Recommendations Based on Expert Consensus Opinion.

    PubMed

    Chen, Jennifer K; Jacob, Sharon E; Nedorost, Susan T; Hanifin, Jon M; Simpson, Eric L; Boguniewicz, Mark; Watsky, Kalman L; Lugo-Somolinos, Aida; Hamann, Carsten R; Eberting, Cheryl Lee; Silverberg, Jonathan I; Thyssen, Jacob P

    2016-01-01

    Allergic contact dermatitis (ACD) may complicate the clinical course of atopic dermatitis (AD), and patch testing remains the criterion standard for diagnosing ACD. To date, there have been no guidelines or consensus recommendations on when and how to patch test individuals with AD. Failure to patch test when appropriate may result in overlooking an important and potentially curable complicating comorbidity. In this article, we present consensus recommendations regarding when to perform patch testing in the AD patient, best practices, and common pitfalls. Patch testing should be considered in AD patients with dermatitis that fails to improve with topical therapy; with atypical/changing distribution of dermatitis, or pattern suggestive of ACD; with therapy-resistant hand eczema in the working population; with adult- or adolescent-onset AD; and/or before initiating systemic immunosuppressants for the treatment of dermatitis. A suggested patch testing algorithm for AD patients is provided.

  2. A localized flare of dermatitis may render patch tests uninterpretable in some patients with recently controlled widespread dermatitis.

    PubMed

    Magembe, Anna J; Davis, Mark D P; Richardson, Donna M

    2009-01-01

    Patch testing rarely is confounded by localized dermatitis induced in the area being tested (usually the back). Its occurrence renders the interpretation of patch tests impossible. To review our experience of the circumstances in which this phenomenon occurs during patch testing. We retrospectively reviewed patients with this phenomenon who underwent patch testing from January 1, 2002, through June 30, 2006. Of the 3,569 patients tested, 12 (0.34% [9 men and 3 women]) had development of this phenomenon. All patients previously had recent widespread dermatitis that was suppressed temporarily with topical corticosteroids and wet dressings at the time of patch testing. The period between control of the dermatitis and the initiation of patch testing was less than 1 week for all patients. Three patients (25%) had recently discontinued therapy with systemic corticosteroids (less than 1 week earlier). In patients with irritable skin either immediately after widespread dermatitis is controlled or after the cessation of systemic corticosteroid treatment, a flare of dermatitis induced by patch testing may render patch tests unreadable and therefore uninterpretable. To avoid this confounding occurrence, a waiting period between control of widespread dermatitis and initiation of patch testing is advised.

  3. Is Patch Testing with Food Additives Useful in Children with Atopic Eczema?

    PubMed

    Catli, Gonul; Bostanci, Ilknur; Ozmen, Serap; Dibek Misirlioglu, Emine; Duman, Handan; Ertan, Ulker

    2015-01-01

    Atopy patch testing is a useful way to determine delayed-type hypersensitivity reactions to foods and aeroallergens. Although food additives have been accused of worsening atopic eczema symptoms, according to recent studies the role of food additives in atopic eczema remains unclear. The purpose of our study was to investigate food additive hypersensitivity in a group of children with atopic eczema by using standardized atopy patch testing and to determine the role of food additive hypersensitivity in atopic eczema. Thirty-four children with atopic eczema and 33 healthy children were enrolled in the study. Children who consumed foods containing additives and did not use either antihistamines or local or systemic corticosteroids for at least 7 days prior to admission were enrolled in the study. All children were subjected to atopy patch testing and after 48 and 72 hours their skin reactions were evaluated by using the guidelines. Positive atopy patch test results were significantly higher in the atopic eczema group. Forty-one percent of the atopic eczema group (n = 14) and 15.2% (n = 5) of the control group had positive atopy patch test results with food additives (p = 0.036) (estimated relative risk 1.68, case odds 0.7, control odds 0.17). Carmine hypersensitivity and the consumption of foods containing carmine, such as gumdrops, salami, and sausage, were significantly higher in the children with atopic eczema. This is the first study investigating hypersensitivity to food additives in children with atopic eczema. Our results indicate that carmine may play a role in atopic eczema. © 2015 Wiley Periodicals, Inc.

  4. Use of patch testing for the diagnosis of abacavir-related hypersensitivity reaction in HIV patients.

    PubMed

    Giorgini, S; Martinelli, C; Tognetti, L; Carocci, A; Giuntini, R; Mastronardi, V; Torricelli, F; Leoncini, F; Lotti, T

    2011-01-01

    The use of antiretroviral drug abacavir (ABC) has been often associated with cutaneous hypersensitivity reactions, the majority being severe. The present study discusses the issues of patch testing associated with pharmacogenetic screening in light of the development of abacavir hypersensitivity reactions (HSRs). The present authors classified 100 patients into three groups: 20 patients (group A) had experienced a hypersensitivity reaction when treated with highly active antiretroviral therapy (HAART) including ABC; 60 HIV-positive patients (group B) were receiving HAART scheme including ABC; 20 HIV-negative patients acted as control group (group C). Patients of group A and B were patch tested with ABC as such, then with an ABC extract diluted to 1 and 10% in petrolatum. Group C patients underwent patches with petrolatum only. A biopsy of the lesion was performed in those patients who showed a positive skin reaction. All patients had been tested for HLA-B5701. A correlation between positive ABC-patch testing and HLA-B5701 was found in 50% of patients enrolled in group A, while in group B and C, all patients tested negative for both genetic marker and ABC-patch testing. Histopathology findings confirmed a vigorous CD4+ and CD8+ cellular response that is compatible with HSR. Patch testing is a safe and sensitive method that can be used for to confirm or exclude any correlation between abacavir and hypersensitivity skin reactions in patients who have been previously treated with abacavir during HAART. Correlation between patch test, immunohistochimical, and genetic tests results shows that genetic testing increases the possibility to identify patients with a true reaction. © 2012 Wiley Periodicals, Inc.

  5. Non-IgE-related diagnostic methods (LST, patch test).

    PubMed

    Matsumoto, Kenji

    2015-01-01

    Although most food allergy patients have immediate-type reactions, some have delayed-type reactions. Unlike for the detection of food-specific IgE antibody in immediate-type (IgE-mediated) food allergies, only a few tests are currently available to aid in the diagnosis of delayed-type (non-IgE-mediated) food allergies. This chapter summarizes our current understanding of one in vitro test and one in vivo test for non-IgE-mediated food allergies: the lymphocyte stimulation test (LST) and the atopy patch test (APT). Although the LST is not yet standardized, a food protein-specific LST might be a useful tool for diagnosing delayed-type food allergies, and especially those manifesting with gastrointestinal symptoms but not skin symptoms. Various remaining issues - including basophil contamination of the peripheral blood mononuclear cell fraction and lipopolysaccharide contamination of food antigen preparations - are also discussed. The APT uses an epicutaneous patch technique to occlusively apply food antigens to the skin to induce inflammatory reactions at the patch application site. Because the APT shows modest sensitivity and specificity, the clinical benefit of the APT in the diagnosis of food allergies in patients with atopic dermatitis is limited. A position paper on the APT issued by the European Academy of Allergy and Clinical Immunology/Global Allergy and Asthma European Network in 2006 is briefly summarized, and several recent APT-related topics, including APT use for the diagnosis of food protein-induced enterocolitis syndrome, are discussed. © 2015 S. Karger AG, Basel.

  6. Lyral has been included in the patch test standard series in Germany.

    PubMed

    Geier, Johannes; Brasch, Jochen; Schnuch, Axel; Lessmann, Holger; Pirker, Claudia; Frosch, Peter J

    2002-05-01

    Lyral 5% pet. was tested in 3245 consecutive patch test patients in 20 departments of dermatology in order (i) to check the diagnostic quality of this patch test preparation, (ii) to examine concomitant reactions to Lyral and fragrance mix (FM), and (iii) to assess the frequency of contact allergy to Lyral in an unselected patch test population of German dermatological clinics. 62 patients reacted to Lyral, i.e. 1.9%. One third of the positive reactions were + + and + + +. The reaction index was 0.27. Thus, the test preparation can be regarded a good diagnostic tool. Lyral and fragrance mix (FM) were tested in parallel in 3185 patients. Of these, 300 (9.4%) reacted to FM, and 59 (1.9%) to Lyral. In 40 patients, positive reactions to both occurred, which is 13.3% of those reacting to FM, and 67.8% of those reacting to Lyral. So the concordance of positive test reactions to Lyral and FM was only slight. Based on these results, the German Contact Dermatitis Research Group (DKG) decided to add Lyral 5% pet. to the standard series.

  7. Impulse Testing of Corporate-Fed Patch Array Antennas

    NASA Technical Reports Server (NTRS)

    Chamberlain, Neil F.

    2011-01-01

    This paper discusses a novel method for detecting faults in antenna arrays. The method, termed Impulse Testing, was developed for corporate-fed patch arrays where the element is fed by a probe and is shorted at its center. Impulse Testing was devised to supplement conventional microwave measurements in order to quickly verify antenna integrity. The technique relies on exciting each antenna element in turn with a fast pulse (or impulse) that propagates through the feed network to the output port of the antenna. The resulting impulse response is characteristic of the path through the feed network. Using an oscilloscope, a simple amplitude measurement can be made to detect faults. A circuit model of the antenna elements and feed network was constructed to assess various fault scenarios and determine fault-detection thresholds. The experimental setup and impulse measurements for two patch array antennas are presented. Advantages and limitations of the technique are discussed along with applications to other antenna array topologies

  8. Effects of time and recall of patch test results on quality of life (QoL) after testing. Cross-sectional study analyzing QoL in hand eczema patients 1, 5 and 10 years after patch testing.

    PubMed

    Jamil, Wasim N; Lindberg, Magnus

    2017-08-01

    Patch testing can improve health-related quality of life (HRQOL). To study the impact on HRQOL of elapsed time after patch testing (1-10 years), and how the outcome of testing and patients' recall affects HRQOL. The Dermatology Life Quality Index (DLQI) questionnaire was sent to all patients (aged 18-65 years) who were patch tested for suspected contact allergy in 2009, 2005 and 2000 at the Department of Dermatology in Örebro. The response rate was 51% (n = 256). The DLQI score was significantly lower at 10 years after patch testing (mean DLQI = 5.5) than at 1 year (mean DLQI = 7.7). Work was the most impaired aspect. A binary logistic model showed that only time (10 years after testing) was associated with no effect, a light effect or a moderate effect (DLQI < 10) on HRQOL. No such association was seen for patients with negative or positive test results concerning full recall, partial recall or no recall of diagnosed allergens. Although there was an improvement in HRQOL over time, the work aspect remained a major problem. The improvement was not affected by the outcome of testing and patients' recall of test results. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Frequency of positive patch test reactions to preservatives: The Australian experience.

    PubMed

    Chow, Elizabeth T; Avolio, Andrea M; Lee, Adriene; Nixon, Rosemary

    2013-02-01

    Preservatives are important causes of allergic contact dermatitis. The frequency of allergy to preservatives in Australia has been unknown to date. Our objectives are to report the frequency of positive preservative patch test reactions in Australia, comparing them to the published international data, as well as exploring the current regulations in place for preservative use in Australia. This was the first retrospective study of patch testing results, aggregated from four patch test clinics in three centres in Melbourne and Sydney. In all, 6845 patients were patch-tested during 1993-2006 and in this period the five most frequent preservative allergens were formaldehyde (4.6%), Euxyl K400 (containing methyldibromo glutaronitrile and phenoxyethanol) (3.3%), quaternium-15 (2.9%), diazolidinyl urea (2.4%), and methylchloroisothiazolinone/methylisothiazolinone (2.3%). These were followed by dimethylol dimethyl DMDM hydantoin (2.1%), chloroacetamide (2.1%) and imidazolidinyl urea (1.9%). The least frequent sensitisers were parabens (1.1%), 2-bromo-2-nitropropane-1, 3-diol (0.9%) and benzyl alcohol (0.4%). Formaldehyde was the most prevalent preservative allergen. Chloroacetamide allergy was more commonly seen in Australia. Parabens, 2-bromo-2-nitropropane-1,3-diol and benzyl alcohol were the least frequent sensitisers. Household products in Australia are not required to list all ingredients preventing sensitised individuals from properly assessing their exposure. © 2012 The Authors Australasian Journal of Dermatology © 2012 The Australasian College of Dermatologists.

  10. Stratum corneum profiles of inflammatory mediators in patch test reactions to common contact allergens and sodium lauryl sulfate.

    PubMed

    Koppes, S A; Ljubojevic Hadzavdic, S; Jakasa, I; Franceschi, N; Jurakić Tončić, R; Marinović, B; Brans, R; Gibbs, S; Frings-Dresen, M H W; Rustemeyer, T; Kezic, S

    2017-06-01

    Recent studies have demonstrated allergen-specific differences in the gene expression of inflammatory mediators in patch tested skin. To determine levels of various inflammatory mediators in the stratum corneum (SC) after patch testing with common contact allergens and the skin irritant sodium lauryl sulfate (SLS). In total, 27 individuals who had previously patch tested positive to nickel, chromium, methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) or para-phenylenediamine were retested and then patch tested with SLS and petrolatum, with petrolatum serving as the patch test control. At 72 h, the test sites were clinically graded and the SC samples collected on adhesive tape. The levels of 18 of the 32 quantified mediators differed significantly from that of the control patches for at least one of the tested substances. SLS and MCI/MI induced the largest number of immunomediators. Interleukin (IL)-16 levels were significantly higher in patch test reactions in all allergens than they were in the controls, while no significant difference was detected for SLS. Furthermore, a strong negative correlation was found between strength of patch test reaction and IL-1α levels. Cytokine profiles in the SC of patch tested skin did not show a distinct allergen-specific pattern. However, MCI/MI induced a larger and wider immune response than the other allergens, perhaps due to its potency as an irritant. The levels of IL-16 were significantly increased in patch test reactions to allergens but not to SLS; thus, they may help clinicians to differentiate between allergic contact dermatitis and irritant contact dermatitis. © 2016 British Association of Dermatologists.

  11. Standardizing the Delivery of 20 μL of Hapten During Patch Testing.

    PubMed

    Selvick, Annika; Stauss, Kari; Strobush, Katrina; Taylor, Lauren; Picard, Alexandra; Doll, Andrea; Reeder, Margo

    2016-01-01

    The current method for patch test tray assembly requires hand dispensing a small volume of hapten onto chambers. Because of human error, this technique produces inaccurate and inconsistent results. The recommended volume of hapten for patch testing using Finn Chambers is 20 μL. The aims of this study were to create a device that standardizes the delivery of 20 μL and to compare it with the current hand dispensing technique. A device, named the Revolution, was created using the SolidWorks program. Five nurses in our Contact Dermatitis Clinic were asked to load 10 Finn Chambers using the current technique and also using the Revolution. Assembly time, volume of petrolatum, and accuracy of placement were measured. After the 3 trials, the nurses completed a survey on the 2 methods. The amount of petrolatum dispensed using the current technique ranged from 16 to 85 μL, with an average amount of 41.39 μL. The Revolution design dispensed an average of 19.78 μL. The current hand dispensing technique does not allow for accurate and consistent dispensing of 20 μL for patch testing. In contrast, the Revolution is an accurate and consistent device that can help standardize the patch testing method.

  12. Patch test reactivity to metal allergens following regulatory interventions: a 33-year retrospective study.

    PubMed

    Thyssen, Jacob Pontoppidan; Ross-Hansen, Katrine; Menné, Torkil; Johansen, Jeanne Duus

    2010-08-01

    Contact allergy epidemics to chromate and nickel were addressed in Denmark in 1983 and 1990 by regulatory interventions. To evaluate whether regulatory interventions on nickel and chromate exposure have reduced the proportion of strong patch test reactions. 22 506 patients with dermatitis aged 4-99 years were patch tested with nickel sulfate, potassium dichromate, or cobalt chloride between 1977 and 2009. The proportion of 3+ reactions to nickel sulfate was reduced and almost disappeared after the mid- and late 1980s (P-trend = 0.001). Today, 1+ and 2+ nickel reactions occur equally frequent. Cobalt chloride patch test reactivity reflected the nickel development to some degree. The proportion of 3+ reactions to potassium dichromate was reduced during the 1980s (P-trend = 0.13), whereas the proportion of 2+ reactions to potassium dichromate have increased in recent years. The decrease in nickel sulfate and cobalt chloride 3+ patch test reactivity began long before the Danish nickel regulation came into effect. This could be because of research activity at the time as well as political attention in Northern Europe. The chromate content in cement regulation may have changed the epidemiology of patch test reactivity; however, in recent years, 2+ reactions to chromate have increased markedly, a development that should be carefully followed.

  13. Repeated applications of a transdermal patch: analytical solution and optimal control of the delivery rate.

    PubMed

    Simon, L

    2007-10-01

    The integral transform technique was implemented to solve a mathematical model developed for percutaneous drug absorption. The model included repeated application and removal of a patch from the skin. Fick's second law of diffusion was used to study the transport of a medicinal agent through the vehicle and subsequent penetration into the stratum corneum. Eigenmodes and eigenvalues were computed and introduced into an inversion formula to estimate the delivery rate and the amount of drug in the vehicle and the skin. A dynamic programming algorithm calculated the optimal doses necessary to achieve a desired transdermal flux. The analytical method predicted profiles that were in close agreement with published numerical solutions and provided an automated strategy to perform therapeutic drug monitoring and control.

  14. The utility of patch tests using larger screening series of allergens.

    PubMed

    Larkin, A; Rietschel, R L

    1998-09-01

    The number of patch test allergens available within the United States for routine commercial purchase is limited. Allergens chosen for inclusion in routine screening series or patch test trays vary, and the degree of information obtained from any series may or may not serve a patient's needs. Knowledge of how well the allergens chosen for inclusion in the two commercially available sources perform compared with a more expansive panel of tests can help physicians select the more appropriate tests. From 1994 to mid-1997, 554 patients were tested with allergens recommended by the North American Contact Dermatitis Group (NACDG). This included all allergens currently available from both current domestic sources, although not in the identical form used by the Thin-layer Rapid Use Epicutaneous Test (TRUE) test (Glaxo Dermatology, Research Triangle Park, NC). Another 185 patients were tested with supplemental series of allergens. The larger the series of allergens used, the more positive tests were found and the more relevant tests as well. Hermal patch test allergens identified about 55% of the information found by the NACDG series; the TRUE test allergens (but not in the TRUE test system) identified 65%. Of the 103 reactions to supplemental allergens not found by the NACDG series, 59 were relevant. Larger series of allergens can enhance accurate diagnosis of allergic contact dermatitis. No single arbitrary series of allergens can adequately survey the contemporary environment of individual patients. Selection of allergens for testing requires consideration of the patient's history and access to appropriate environmental contactants.

  15. Patch test results of the dental personnel with contact dermatitis.

    PubMed

    Kocak, Oguzhan; Gul, Ulker

    2014-12-01

    Dental personnel have high risk of occupational contact dermatitis. The aim of this study is to detect the materials which cause contact sensitization and the frequency of contact dermatitis by using patch tests with European standard series and dental screening series in dental personnel. Between August 2008 and July 2009, 461 dental personnel working in Ankara (Turkey) were examined and age, gender, previous history of dermatitis, area of the skin affected and clinical diagnosis were noted. About 198 (43%) of the dental personnel were diagnosed contact dermatitis. Sixty-five of the dental personnel accepted to be patch tested. Dental technicians, dentists and dental nurses constitute 69.2%, 24.6% and 6.2% of patch tested 65 patients, respectively. Positive reactions to at least one allergen were detected with European standard series at 20% and with dental series at 10.8% among the dental personnel. The most common allergens were nickel sulfate (12.3%), acrylates (6.1%) and para-tertiary-butylphenol-formaldehyde resin (4.6%). The most common acrylate was ethyleneglycol dimethacrylate (3.1%). We believe our study will be helpful to dermatologists about frequency of contact dermatitis among dental personnel and allergens that cause contact sensitivity for developing new methods to protect the personnel in dentistry against sensitization.

  16. Designing and testing a wearable, wireless fNIRS patch.

    PubMed

    Abtahi, Mohammadreza; Cay, Gozde; Saikia, Manob Jyoti; Mankodiya, Kunal

    2016-08-01

    Optical brain monitoring using near infrared (NIR) light has got a lot of attention in order to study the complexity of the brain due to several advantages as oppose to other methods such as EEG, fMRI and PET. There are a few commercially available functional NIR spectroscopy (fNIRS) brain monitoring systems, but they are still non-wearable and pose difficulties in scanning the brain while the participants are in motion. In this work, we present our endeavors to design and test a low-cost, wireless fNIRS patch using NIR light sources at wavelengths of 770 and 830nm, photodetectors and a microcontroller to trigger the light sources, read photodetector's output and transfer data wirelessly (via Bluetooth) to a smart-phone. The patch is essentially a 3-D printed wearable system, recording and displaying the brain hemodynamic responses on smartphone, also eliminates the need for complicated wiring of the electrodes. We have performed rigorous lab experiments on the presented system for its functionality. In a proof of concept experiment, the patch detected the NIR absorption on the arm. Another experiment revealed that the patch's battery could last up to several hours with continuous fNIRS recording with and without wireless data transfer.

  17. Lessons from atopy patch testing in atopic dermatitis.

    PubMed

    Kerschenlohr, Karin; Darsow, Ulf; Burgdorf, Walter H C; Ring, Johannes; Wollenberg, Andreas

    2004-07-01

    The exposure of atopic eczema (AE) patients to their relevant protein allergens (eg, from house dust mite, cat dander, grass pollen, or food allergens) can trigger an exacerbation or maintain the disease. Diagnostic procedures are needed to specify allergen avoidance recommendations for the individual patient. Skin prick tests and specific serum IgE tests might be helpful in pointing out potential trigger factors, but relevance needs to be confirmed (eg, with food provocation tests). The atopy patch test (APT) involves the epicutaneous application of intact protein allergens in a diagnostic patch test setting with an evaluation of the induced eczematous skin lesions after 24 to 72 hours. The APT targets the cellular component of AE and helps round out the AE test spectrum. As a number of apparently minor test modifications greatly influence the sensitivity, specificity, and reproducibility of the APT, the European Task Force on Atopic Dermatitis (ETFAD) has developed a standardized APT technique. It consists of purified allergen preparations in petrolatum, applied in 12-mm diameter Finn chambers mounted on Scanpor tape to non-irritated, non-abraded, or tape-stripped skin of the upper back. The APT is read at 48 and 72 hours according to the test criteria and reading key of the ETFAD for appearance of erythema, and number and distribution pattern of the papules. In contrast with skin prick tests, the APT might even detect a relevant sensitization in the absence of specific IgE. Many studies have been undertaken to objectify the sensitivity and specificity of the APT to show its diagnostic use in clinical practice.

  18. Patch testing with thin-layer chromatograms of chamomile tea in patients allergic to sesquiterpene lactones.

    PubMed

    Lundh, Kerstin; Gruvberger, Birgitta; Möller, Halvor; Persson, Lena; Hindsén, Monica; Zimerson, Erik; Svensson, Ake; Bruze, Magnus

    2007-10-01

    Patients with contact allergy to sesquiterpene lactones (SLs) are usually hypersensitive to Asteraceae plant products such as herbal teas. The objective of this study was to show sensitizers in chamomile tea by patch testing with thin-layer chromatograms. Tea made from German chamomile was separated by thin-layer chromatography. Strips of the thin-layer chromatograms were used for patch testing SL-positive patients. 15 (43%) of 35 patients tested positively to 1 or more spots on the thin-layer chromatogram, with many individual reaction patterns. Patch testing with thin-layer chromatograms of German chamomile tea showed the presence of several allergens.

  19. Is the European standard series suitable for patch testing in Riyadh, Saudi Arabia?

    PubMed

    el-Rab, M O; al-Sheikh, O A

    1995-11-01

    Due to the lack of a regional patch test series in our geographical area, the suitability of the European standard series was evaluated by patch testing dermatitis patients in Riyadh, Saudi Arabia. Of 240 consecutive patients with various forms of dermatitis, 136 (57%) showed 1 or more positive patch tests, women, 74 (54%), slightly outnumbering men, 62 (46%). Positive reactions were found to 21 of the 22 items in the test series. Sensitization was most common to nickel sulfate (51 = 37.5%), potassium dichromate (48 = 35%) and cobalt chloride (43 = 32%) The frequency of sensitization to nickel was higher in women (41 = 30%) while that to dichromate was higher in men (39 = 29%). Less reactions were found to fragrance mix (21 = 15%), formaldehyde (15 = 11%) and neomycin sulfate (15 = 11%). Sensitization to other allergens ranged between 10 and 1%. Less than 1% of patients (0.7%) reacted to benzocaine and none to primin. The frequency of occurrence of multiple sensitivities is also presented. We conclude that the European standard series is suitable for patch testing dermatitis patients in our region, with the exception of benzocaine and primin. The addition of 3 allergens that could be of local relevance is discussed.

  20. Pesticide patch test series for the assessment of allergic contact dermatitis among banana plantation workers in panama.

    PubMed

    Penagos, Homero; Ruepert, Clemens; Partanen, Timo; Wesseling, Catharina

    2004-09-01

    Irritant contact dermatitis and allergic contact dermatitis (ACD) are frequent among agricultural workers and require targeted interventions. Patch testing is necessary for differential diagnosis, but patch testing with pesticides is uncommon. This study explores the frequency of ACD and sensitization to pesticides among highly exposed banana plantation workers. Frequently and recently used pesticides on banana plantations in Divala, Panama, were documented. A pesticide patch test tray specific for this population was prepared. A structured interview was administered to 366 participants, followed by a complete skin examination. The pesticide patch test series, as well as a standard patch test series, was applied to 37 workers with dermatoses likely to be pesticide related and to 23 control workers without dermatoses. The pesticide patch tests identified 15 cases (41%) of ACD (20 positive reactions) among the 37 workers diagnosed with pesticide dermatosis. Three controls had allergic reactions to pesticides (4 positive reactions). The pesticides were carbaryl (5 cases), benomyl (4 cases), ethoprophos (3), chlorothalonil (2), imazalil (2), glyphosate (2), thiabendazole (2), chlorpyrifos (1), oxyfluorfen (1), propiconazole (1), and tridemorph (1). Ethoprophos and tridemorph had not been previously identified as sensitizers. Thus, the prevalence of ACD was 0.03 (15 of 366). On the basis of observed prevalences of positive patch-test reactions among the subgroups with and without dermatoses, we estimated that > or = 16% of the entire population may be sensitized to pesticides. Sensitization to pesticides among banana plantation workers is a frequent occupational health problem. Pesticide patch test trays should be used in assessing skin diseases in highly exposed workers.

  1. Design, development, physicochemical, and in vitro and in vivo evaluation of transdermal patches containing diclofenac diethylammonium salt.

    PubMed

    Arora, Priyanka; Mukherjee, Biswajit

    2002-09-01

    In this study, matrix-type transdermal patches containing diclofenac diethylamine were prepared using different ratios of polyvinylpyrrolidone (PVP) and ethylcellulose (EC) by solvent evaporation technique. The drug matrix film of PVP and EC was casted on a polyvinylalcohol backing membrane. All the prepared formulations were subjected to physical studies (moisture content, moisture uptake, and flatness), in vitro release studies and in vitro skin permeation studies. In vitro permeation studies were performed across cadaver skin using a modified diffusion cell. Variations in drug release profiles among the formulations studied were observed. Based on a physicochemical and in vitro skin permeation study, formulation PA4 (PVP/EC, 1:2) and PA5 (PVP/EC, 1:5) were chosen for further in vivo experiments. The antiinflammatory effect and a sustaining action of diclofenac diethylamine from the two transdermal patches selected were studied by inducing paw edema in rats with 1% w/v carrageenan solution. When the patches were applied half an hour before the subplantar injection of carrageenan in the hind paw of male Wistar rats, it was observed that formulation PA4 produced 100% inhibition of paw edema in rats 12 h after carrageenan insult, whereas in the case of formulation PA5, 4% mean paw edema was obtained half an hour after the carrageenan injection and the value became 19.23% 12 h after the carrageenan insult. The efficacy of transdermal patches was also compared with the marketed Voveran gel and it was found that PA4 transdermal patches produced a better result as compared with the Voveran gel. Hence, it can be reasonably concluded that diclofenac diethylamine can be formulated into the transdermal matrix type patches to sustain its release characteristics and the polymeric composition (PVP/EC, 1:2) was found to be the best choice for manufacturing transdermal patches of diclofenac diethylamine among the formulations studied. Copyright 2002 Wiley-Liss, Inc.

  2. FOOT ECZEMA: THE ROLE OF PATCH TEST IN DETERMINING THE CAUSATIVE AGENT USING STANDARD SERIES

    PubMed Central

    Priya, K S; Kamath, Ganesh; Martis, Jacintha; D, Sukumar; Shetty, Narendra J; Bhat, Ramesh M; Kishore, B Nanda

    2008-01-01

    Foot dermatitis refers to the predominant involvement of feet in the eczematous process. This study is undertaken to determine the clinical pattern and causative agent in foot eczema and to evaluate the role of patch testing in determining the causative agent of foot eczema. Data was collected from 50 patients with foot eczema, who attended the out-patient department. The patch test was performed using Indian standard series. Patch test was positive in 88% of the patients. The most common site affected was the dorsal aspect of the foot (48%) and scaly plaque was the predominant morphological pattern. The highest number of patients (24%) showed positive reactions to mercaptobenzothiazole (MBT) and the lowest (4%) to neomycin sulfate. Rubber and rubber chemicals have been reported worldwide to be the most common sensitizer causing foot eczema. Thus, patch test has a major role in finding out the cause of foot eczema. PMID:19881990

  3. North American Contact Dermatitis Group patch test results for 2007-2008.

    PubMed

    Fransway, Anthony F; Zug, Kathryn A; Belsito, Donald V; Deleo, Vincent A; Fowler, Joseph F; Maibach, Howard I; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Rietschel, Robert L; Sasseville, Denis; Storrs, Frances J; Taylor, James S; Warshaw, Erin M; Dekoven, Joel; Zirwas, Matthew

    2013-01-01

    The North American Contact Dermatitis Group (NACDG) tests patients with suspected allergic contact dermatitis to a broad series of screening allergens and publishes periodic reports. The aims of this study were to report the NACDG patch-testing results from January 1, 2007, to December 31, 2008, and to compare results to pooled test data from the previous 2 and 10 years to analyze trends in allergen sensitivity. Standardized patch testing with 65 allergens was used at 13 centers in North America. χ analysis was used for comparisons. A total of 5085 patients were tested; 11.8% (598) had an occupationally related skin condition, and 65.3% (3319) had at least 1 allergic patch test reaction, which is identical to the NACDG data from 2005 to 2006. The top 15 most frequently positive allergens were nickel sulfate (19.5%), Myroxylon pereirae (11.0%), neomycin (10.1%), fragrance mix I (9.4%), quaternium-15 (8.6%), cobalt chloride (8.4%), bacitracin (7.9%), formaldehyde (7.7%), methyldibromoglutaronitrile/phenoxyethanol (5.5%), p-phenylenediamine (5.3%), propolis (4.9%), carba mix (4.5%), potassium dichromate (4.1%), fragrance mix II (3.6%), and methylchloroisothiazolinone/methylisothiazolinone (3.6%). There were significant increases in positivity rates to nickel, methylchloroisothiazolinone/methylisothiazolinone, and benzophenone-3. During the same period of study, there were significant decreases in positivity rates to neomycin, fragrance mix I, formaldehyde, thiuram mix, cinnamic aldehyde, propylene glycol, epoxy resin, diazolidinyl urea, amidoamine, ethylenediamine, benzocaine, p-tert-butylphenol formaldehyde resin, dimethylol dimethyl hydantoin, cocamidopropyl betaine, glutaraldehyde, mercaptobenzothiazole, tosylamide formaldehyde resin, budesonide, disperse blue 106, mercapto mix, and chloroxylenol. Twenty-four percent (1221) had a relevant positive reaction to a non-NACDG supplementary allergen; and 180 of these reactions were occupationally relevant. Periodic

  4. Is there a role of food additives in recurrent aphthous stomatitis? A prospective study with patch testing.

    PubMed

    Gülseren, Duygu; Hapa, Asli; Ersoy-Evans, Sibel; Elçin, Gonca; Karaduman, Ayşen

    2017-03-01

    Recurrent aphthous stomatitis (RAS) is a common disease of the oral mucosa with an unknown etiology. This study aimed to determine if food additives play a role in the etiology of RAS as well as to determine if patch testing can be used to detect which allergens cause RAS. This prospective study included 24 patients with RAS and 22 healthy controls. All the participants underwent patch testing for 23 food additives. In total, 21 (87.5%) RAS patients and 3 (13.6%) controls had positive patch test reactions to ≥1 allergens; the difference in the patch test positivity rate between groups was significant (P < 0.05). The most common allergen that elicited positive patch test results in the patient group was cochineal red (n = 15 [62.5%]), followed by azorubine (n = 11 [45.8%]) and amaranth (n = 6 [25%]). The present findings show that food additives might play a role in the etiology of RAS and that patch testing could be a method for determining the etiology of RAS. © 2016 The International Society of Dermatology.

  5. Monitoring contact sensitization to p-phenylenediamine (PPD) by patch testing with PPD 0.3% in petrolatum.

    PubMed

    Geier, Johannes; Ballmer-Weber, Barbara K; Dickel, Heinrich; Frosch, Peter J; Bircher, Andreas; Weisshaar, Elke; Hillen, Uwe

    2013-07-01

    Being a contact allergen of general relevance, p-phenylenediamine (PPD) is patch tested in the baseline series. However, PPD 1% in petrolatum may actively sensitize. Patch testing with PPD at 0.35% pet. proved to be safe, as far as active sensitization is concerned. To determine whether PPD 0.3% pet. reliably detects PPD sensitization. Patch testing with PPD 0.3% pet. and 1% pet. synchronously was performed in consecutive patients in a multicentre study within the Information Network of Departments of Dermatology. Altogether, 2042 patients were patch tested. PPD 1% pet. yielded 6.0% positive reactions (n = 123), and PPD 0.3% pet. yielded 4.7% (n = 95). The synchronous reproducibility of PPD reactions was similar as known from parallel patch tests with identical PPD concentrations. The diagnostic properties of PPD 0.3% pet. expressed as reaction index and positivity ratio were good. Of the 123 patients reacting to PPD 1% pet., 32 (26%) had no positive reaction to PPD 0.3% pet. In 22 of these 32 patients (69%), no clinical relevance could be found. As patch testing with PPD 0.3% pet. is reliable according to our results, we recommend replacing PPD 1% pet. in the baseline series with PPD 0.3% pet. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Validation of a novel epicutaneous delivery system for patch testing of house dust mite-hypersensitive dogs.

    PubMed

    Olivry, Thierry; Linder, Keith E; Paps, Judy S; Bizikova, Petra; Dunston, Stan; Donne, Nathalie; Mondoulet, Lucie

    2012-12-01

    Patch tests with allergens are used for the evaluation of cellular hypersensitivity to food and environmental allergens in dogs and humans with atopic dermatitis. Viaskin is a novel allergen epicutaneous delivery system that enhances epidermal allergen capture by immune cells. To compare the use of Viaskin and Finn chamber patch tests in dogs hypersensitive to mite allergens. Empty control or Dermatophagoides farinae house dust mite-containing Viaskin or Finn chamber patches were applied to the thoracic skin of six mite-hypersensitive Maltese-beagle crossbred atopic dogs. Lesions were graded 49 and 72 h after patch test application, and skin biopsies were collected after 72 h. Overall microscopic inflammation, eosinophil and T-lymphocyte infiltrations were scored. Positive macroscopic patch test reactions developed at five of six Viaskin application sites and four of six Finn chamber application sites. Median microscopic epidermal and dermal inflammation, as well as eosinophil and CD3 T-lymphocyte dermal scores were always higher in biopsies collected at Viaskin than at Finn chamber sites. Microscopic inflammation scores were significantly higher after mite allergen-containing Viaskin compared with empty patches, but this was not the case for mite-containing Finn chambers compared with control chambers. Scores obtained using Viaskin were not significantly different from those obtained using Finn chambers. Macroscopic and microscopic scores were significantly correlated. In mite-allergic dogs, Viaskin epicutaneous delivery systems appear to induce stronger allergen-specific inflammation than currently used Finn chamber patch tests. Consequently, Viaskin patches might offer a better alternative for screening cellular hypersensitivity to food and environmental allergens. © 2012 The Authors. Veterinary Dermatology © 2012 ESVD and ACVD.

  7. Environmental insults: critical triggers for amyotrophic lateral sclerosis.

    PubMed

    Yu, Bing; Pamphlett, Roger

    2017-01-01

    Amyotrophic lateral sclerosis (ALS) is a fatal neurodegenerative disease characterised by a rapid loss of lower and upper motor neurons. As a complex disease, the ageing process and complicated gene-environment interactions are involved in the majority of cases. Significant advances have been made in unravelling the genetic susceptibility to ALS with massively parallel sequencing technologies, while environmental insults remain a suspected but largely unexplored source of risk. Several studies applying the strategy of Mendelian randomisation have strengthened the link between environmental insults and ALS, but none so far has proved conclusive. We propose a new ALS model which links the current knowledge of genetic factors, ageing and environmental insults. This model provides a mechanism as to how ALS is initiated, with environmental insults playing a critical role. The available evidence has suggested that inherited defect(s) could cause mitochondrial dysfunction, which would establish the primary susceptibility to ALS. Further study of the underlying mechanism may shed light on ALS pathogenesis. Environmental insults are a critical trigger for ALS, particularly in the aged individuals with other toxicant susceptible genes. The identification of ALS triggers could lead to preventive strategies for those individuals at risk.

  8. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    PubMed

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  9. North American Contact Dermatitis Group patch test results: 2009 to 2010.

    PubMed

    Warshaw, Erin M; Belsito, Donald V; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Zirwas, Matthew J; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Maibach, Howard I

    2013-01-01

    Patch testing is an important diagnostic tool for determination of substances responsible for allergic contact dermatitis. This study reports the North American Contact Dermatitis Group (NACDG) patch testing results from January 1, 2009, to December 31, 2010. At 12 centers in North America, patients were tested in a standardized manner with a screening series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends were analyzed using χ2 statistics. A total of 4308 patients were tested. Of these, 2614 (60.7%) had at least 1 positive reaction, and 2284 (46.3%) were ultimately determined to have a primary diagnosis of allergic contact dermatitis. Four hundred twenty-seven (9.9%) patients had occupationally related skin disease. There were 6855 positive allergic reactions. As compared with the previous reporting period (2007-2008), the positive reaction rates statistically decreased for 20 allergens (nickel, neomycin, Myroxylon pereirae, cobalt, formaldehyde, quaternium 15, methydibromoglutaronitrile/phenoxyethanol, methylchlorisothiazolinone/methylisothiazolinone, potassium dichromate, diazolidinyl urea, propolis, dimethylol dimethylhydantoin, 2-bromo-2-nitro-1,3-propanediol, methyl methacrylate, ethyl acrylate, glyceryl thioglycolate, dibucaine, amidoamine, clobetasol, and dimethyloldihydroxyethyleneurea; P < 0.05) and statistically increased for 4 allergens (fragrance mix II, iodopropynyl butylcarbamate, propylene glycol, and benzocaine; P < 0.05). Approximately one quarter of tested patients had at least 1 relevant allergic reaction to a non-NACDG allergen. Hypothetically, approximately one quarter of reactions detected by NACDG allergens would have been missed by TRUE TEST (SmartPractice Denmark, Hillerød, Denmark). These results affirm the value of patch testing with many allergens.

  10. The Effects of Repeaters on Test Equating.

    ERIC Educational Resources Information Center

    Andrulis, Richard S.; And Others

    1978-01-01

    The effects of repeaters (testees included in both administrations of two forms of a test) on the test equating process are examined. It is shown that repeaters do effect test equating and tend to lower the cutoff point for passing the test. (JKS)

  11. Patch testing in Australia: Is it adequate?

    PubMed

    Tizi, Stephanie; Nixon, Rosemary L

    2016-08-01

    Patch testing (PT) is essential for making the diagnosis of allergic contact dermatitis (ACD). However, the extent of PT undertaken by Australian dermatologists is unknown. The objectives of this study were to determine the rate and type of PT in Australia, the perceived obstacles to PT, and to explore the exposure to PT in dermatology training. Data were collected on private PT (analysing Medicare item numbers) and public hospital-based PT (estimated via verbal reports). An online survey on PT was sent to Fellows of the Australasian College of Dermatologists. It was found that total PT numbers, combining Medicare item number and public hospital data, were below the suggested optimum in all states and in Australia overall. Of the 173 respondents to the survey, 61% reported they patch tested and 78% reported they referred for PT. TrueTest was the most commonly used PT system, although it is known to be inadequate. Dermatologists who PT as registrars were significantly more likely to PT as consultants (P value = 0.0029). Cost, expertise required and staffing were considered major obstacles to performing PT. Accessibility and cost to the patient were common obstacles to referral. The combination of suboptimal PT rates and inadequate PT means that patients are missing out on being diagnosed with ACD in Australia. Increasing the exposure of registrars to PT, supporting specialised centres, the development of the Australian Baseline Series and the Contact Allergen Bank will, it is hoped, improve the rates of comprehensive PT in Australia. © 2015 The Australasian College of Dermatologists.

  12. Systemic Prenatal Insults Disrupt Telencephalon Development

    PubMed Central

    Robinson, Shenandoah

    2006-01-01

    Infants born prematurely are prone to chronic neurologic deficits including cerebral palsy (CP), epilepsy, cognitive delay, behavioral problems, and neurosensory impairments. In affected children, imaging and neuropathological findings demonstrate significant damage to white matter. The extent of cortical damage has been less obvious. Advances in the understanding of telencephalon development provide insights into how systemic intrauterine insults affect the developing white matter, subplate and cortex, and lead to multiple neurologic impairments. In addition to white matter oligodendrocytes and axons, other elements at risk for perinatal brain injury include subplate neurons, GABAergic neurons migrating through white matter and subplate, and afferents of maturing neurotransmitter systems. Common insults including hypoxia-ischemia and infection often affect the developing brain differently than the mature brain, and insults precipitate a cascade of damage to multiple neural lineages. Insights from development can identify potential targets for therapies to repair the damaged neonatal brain before it has matured. PMID:16061421

  13. Intraoperative Secondary Insults During Orthopedic Surgery in Traumatic Brain Injury.

    PubMed

    Algarra, Nelson N; Lele, Abhijit V; Prathep, Sumidtra; Souter, Michael J; Vavilala, Monica S; Qiu, Qian; Sharma, Deepak

    2017-07-01

    Secondary insults worsen outcomes after traumatic brain injury (TBI). However, data on intraoperative secondary insults are sparse. The primary aim of this study was to examine the prevalence of intraoperative secondary insults during orthopedic surgery after moderate-severe TBI. We also examined the impact of intraoperative secondary insults on postoperative head computed tomographic scan, intracranial pressure (ICP), and escalation of care within 24 hours of surgery. We reviewed medical records of TBI patients 18 years and above with Glasgow Coma Scale score <13 who underwent single orthopedic surgery within 2 weeks of TBI. Secondary insults examined were: systemic hypotension (systolic blood pressure<90 mm Hg), intracranial hypertension (ICP>20 mm Hg), cerebral hypotension (cerebral perfusion pressure<50 mm Hg), hypercarbia (end-tidal CO2>40 mm Hg), hypocarbia (end-tidal CO2<30 mm Hg in absence of intracranial hypertension), hyperglycemia (glucose>200 mg/dL), hypoglycemia (glucose<60 mg/dL), and hyperthermia (temperature >38°C). A total of 78 patients (41 [18 to 81] y, 68% male) met the inclusion criteria. The most common intraoperative secondary insults were systemic hypotension (60%), intracranial hypertension and cerebral hypotension (50% and 45%, respectively, in patients with ICP monitoring), hypercarbia (32%), and hypocarbia (29%). Intraoperative secondary insults were associated with worsening of head computed tomography, postoperative decrease of Glasgow Coma Scale score by ≥2, and escalation of care. After Bonferroni correction, association between cerebral hypotension and postoperative escalation of care remained significant (P<0.001). Intraoperative secondary insults were common during orthopedic surgery in patients with TBI and were associated with postoperative escalation of care. Strategies to minimize intraoperative secondary insults are needed.

  14. EAACI position paper for practical patch testing in allergic contact dermatitis in children.

    PubMed

    de Waard-van der Spek, Flora B; Darsow, Ulf; Mortz, Charlotte G; Orton, David; Worm, Margitta; Muraro, Antonella; Schmid-Grendelmeier, Peter; Grimalt, Ramon; Spiewak, Radoslaw; Rudzeviciene, Odilija; Flohr, Carsten; Halken, Susanne; Fiocchi, Alessandro; Borrego, Luis Miguel; Oranje, Arnold P

    2015-11-01

    Allergic contact dermatitis (ACD) in children appears to be on the increase, and contact sensitization may already begin in infancy. The diagnosis of contact dermatitis requires a careful evaluation of a patient's clinical history, physical examination, and skin testing. Patch testing is the gold standard diagnostic test. Based on consensus, the EAACI Task Force on Allergic Contact Dermatitis in Children produced this document to provide details on clinical aspects, the standardization of patch test methodology, and suggestions for future research in the field. We provide a baseline list of test allergens to be tested in children with suspected ACD. Additional tests should be performed only on specific indications. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Positive concomitant test reactions to allergens in the standard patch test series.

    PubMed

    Landeck, Lilla; González, Ernesto; Baden, Lynn; Neumann, Konrad; Schalock, Peter

    2010-05-01

    Patch testing is performed to evaluate suspected allergic contact dermatitis. Common wisdom suggests that various allergens cross-react but only a few larger studies have published confirmations of this. The purpose of our study was to identify significant correlations between positive test reactions in a screening series. A total of 1235 patients undergoing patch testing to the Hermal standard series at the Massachusetts General Hospital, Contact Dermatitis Clinic between 1990 and 2006 were investigated. Two or more positive reactions were seen in 411 patients (33.3%). Sensitizations to eight pairs of allergens were found to have significant correlation (P

  16. Patch tests with fragrance mix II and its components.

    PubMed

    Pónyai, Györgyi; Németh, Ilona; Altmayer, Anita; Nagy, Gabriella; Irinyi, Beatrix; Battyáni, Zita; Temesvári, Erzsébet

    2012-01-01

    Fragrance mix II (FM II) was initiated to detect contact hypersenstitivity (CH) to fragrances that could not have been identified previously. The aim of this multicenter study was to map the frequency of CH to FM II and its components in Hungary. Six centers participated in the survey from 2009 to 2010. A total off 565 patients (434 women and 131 men) with former skin symptoms provoked by scented products were patch tested. The tests were performed with Brial GmbH D-Greven allergens. In the environmental patch test series, FM II, FM I, Myroxylon pereirae, colophonium, wood-tar mix, propolis, and sesquiterpene lactone mix were tested as fragrance allergens. The FM II components (citral, farnesol, coumarin, citronellol, α-hexyl-cinnamaldehyde, and hydroxy-isohexyl-3-cyclohexene-carboxaldehyde [Lyral]) were also tested. Contact hypersenstitivity to any fragrances was detected in 28.8%, to FM II in 17.2% of the patients. Contact hypersenstitivity to hydroxy-isohexyl-3-cyclohexene-carboxaldehyde was observed in 7.3%, to coumarin in 5.1%, to α-hexyl-cinnamaldehyde in 3.5%, to citral in 3.4%, to farnesol in 2.5%, and to citronellol in 1.2%. Of the FM II-positive cases, 48.4% showed isolated CH reaction. The frequency of CH to FM II is 17.2% in the tested, selected Hungarian population. The CH to FM II and its components could not have been revealed without the present test materials.

  17. Concentrations and stability of methyl methacrylate, glutaraldehyde, formaldehyde and nickel sulfate in commercial patch test allergen preparations.

    PubMed

    Siegel, Paul D; Fowler, Joseph F; Law, Brandon F; Warshaw, Erin M; Taylor, James S

    2014-05-01

    Epicutaneous patch tests are used to reproduce allergy and diagnose allergic contact dermatitis. Reliable allergen test preparations are required. The purpose of the present study was to measure the actual concentrations of nickel(II) sulfate hexahydrate (NiSO4 ), methyl methacrylate, formaldehyde, and glutaraldehyde, and to compare them with the labelled concentrations, in commercial patch test allergen preparations found in dermatology clinics where patch testing is routinely performed. The commercial in-date and out-of-date patch test allergen preparations concentrations of NiSO4 , methyl methacrylate, formaldehyde and glutaraldehyde from one to three participating clinics were analysed with chromatographic or wet chemical techniques. NiSO4 and formaldehyde concentrations were at or above the labelled concentrations; however, formaldehyde loss occurred with storage. NiSO4 particulate was uniformly distributed throughout the petrolatum. 'In-use' methyl methacrylate reagent syringes all contained ≤ 56% of the 2% label concentration, with no observable relationship with expiration date. Lower methyl methacrylate cocentrations were consistently measured at the syringe tip end, suggesting loss resulting from methyl methacrylate's volatility. The concentrations of glutaraldehyde patch test allergen preparations ranged from 27% to 45% of the labelled (1% in pet.) concentration, independently of expiration date. Some false-negative methyl methacrylate, formaldehyde or glutaraldehyde patch test results may be attributable to instability of the test preparations. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Is Housing a Health Insult?

    PubMed Central

    Baker, Emma; Beer, Andrew; Lester, Laurence; Pevalin, David; Whitehead, Christine; Bentley, Rebecca

    2017-01-01

    In seeking to understand the relationship between housing and health, research attention is often focussed on separate components of people’s whole housing ‘bundles’. We propose in this paper that such conceptual and methodological abstraction of elements of the housing and health relationship limits our ability to understand the scale of the accumulated effect of housing on health and thereby contributes to the under-recognition of adequate housing as a social policy tool and powerful health intervention. In this paper, we propose and describe an index to capture the means by which housing bundles influence health. We conceptualise the index as reflecting accumulated housing “insults to health”—an Index of Housing Insults (IHI). We apply the index to a sample of 1000 low-income households in Australia. The analysis shows a graded association between housing insults and health on all outcome measures. Further, after controlling for possible confounders, the IHI is shown to provide additional predictive power to the explanation of levels of mental health, general health and clinical depression beyond more traditional proxy measures. Overall, this paper reinforces the need to look not just at separate housing components but to embrace a broader understanding of the relationship between housing and health. PMID:28587139

  19. Patch test responses to Malassezia pachydermatis in healthy basset hounds and in basset hounds with Malassezia dermatitis.

    PubMed

    Bond, R; Patterson-Kane, J C; Perrins, N; Lloyd, D H

    2006-08-01

    The effects of the patch test application of Malassezia pachydermatis extracts were evaluated in seven healthy basset hounds and in seven basset hounds with Malassezia dermatitis. Antigens (4 and 0.4 mg/ml) and saline controls were applied for 48 h using filter paper discs in Finn chambers. One healthy basset hound and five affected hounds showed positive patch test reactivity to the yeast antigens. Positive patch test reactions were characterized histologically by mild epidermal hyperplasia and mild to moderate perivascular, periadnexal and interstitial infiltrates of neutrophils and CD3+ lymphocytes. Immediate intradermal test reactivity to M. pachydermatis antigens was seen in one healthy and one affected hound, whereas delayed intradermal test reactivity was seen in six healthy hounds and five affected hounds. This study indicates that patch test reactivity to M. pachydermatis antigen may occur in healthy basset hounds, and in contrast to delayed intradermal test reactivity, is more frequent in basset hounds with Malassezia dermatitis.

  20. Patch testing with fragrance mix II: results of the IVDK 2005-2008.

    PubMed

    Krautheim, Andrea; Uter, Wolfgang; Frosch, Peter; Schnuch, Axel; Geier, Johannes

    2010-11-01

    The fragrance mix (FM I), established in 1977, detects the majority, but not all cases of contact allergy to fragrances. Based on European research 2002/2003, fragrance mix II (FM II) was developed to supplement FM I. In 2005, the German Contact Dermatitis Research Group (DKG) added FM II to their baseline series. To evaluate reactions to FM II and its constituents in routine patch testing. Retrospective data analysis of the Information Network of Departments of Dermatology (IVDK), 2005-2008, of patch test results with FM II and its constituents. A total of 35 633 patients were patch tested with FM II as part of the DKG baseline series. Of these, 1742 (4.9%) reacted positively. Concomitant reactions to FM I were observed in 41.9% of the patients reacting to FM II. In 367 FM II-positive patients, a full breakdown test of the mix was performed. Of these, 47.7% reacted to hydroxyisohexyl 3-cyclohexene carboxaldehyde, 16.1% to citral, 11.4% to farnesol, 3.8% to hexyl cinnamal, 2.7% to coumarin, and 2.5% to citronellol. FM II is an important screening and diagnostic tool to detect fragrance allergy. Hydroxyisohexyl 3-cyclohexene carboxaldehyde is the most important fragrance allergen in FM II. © 2010 John Wiley & Sons A/S.

  1. Attitudes about Advances in Sweat Patch Testing in Drug Courts: Insights from a Case Study in Southern California

    ERIC Educational Resources Information Center

    Polzer, Katherine

    2010-01-01

    Drug courts are reinventing the drug testing framework by experimenting with new methods, including use of the sweat patch. The sweat patch is a band-aid like strip used to monitor drug court participants. The validity and reliability of the sweat patch as an effective testing method was examined, as well as the effectiveness, meaning how likely…

  2. Patch size has no effect on insect visitation rate per unit area in garden-scale flower patches

    NASA Astrophysics Data System (ADS)

    Garbuzov, Mihail; Madsen, Andy; Ratnieks, Francis L. W.

    2015-01-01

    Previous studies investigating the effect of flower patch size on insect flower visitation rate have compared relatively large patches (10-1000s m2) and have generally found a negative relationship per unit area or per flower. Here, we investigate the effects of patch size on insect visitation in patches of smaller area (range c. 0.1-3.1 m2), which are of particular relevance to ornamental flower beds in parks and gardens. We studied two common garden plant species in full bloom with 6 patch sizes each: borage (Borago officinalis) and lavender (Lavandula × intermedia 'Grosso'). We quantified flower visitation by insects by making repeated counts of the insects foraging at each patch. On borage, all insects were honey bees (Apis mellifera, n = 5506 counts). On lavender, insects (n = 737 counts) were bumble bees (Bombus spp., 76.9%), flies (Diptera, 22.4%), and butterflies (Lepidoptera, 0.7%). On both plant species we found positive linear effects of patch size on insect numbers. However, there was no effect of patch size on the number of insects per unit area or per flower and, on lavender, for all insects combined or only bumble bees. The results show that it is possible to make unbiased comparisons of the attractiveness of plant species or varieties to flower-visiting insects using patches of different size within the small scale range studied and make possible projects aimed at comparing ornamental plant varieties using existing garden flower patches of variable area.

  3. Recommendation to test limonene hydroperoxides 0·3% and linalool hydroperoxides 1·0% in the British baseline patch test series.

    PubMed

    Wlodek, C; Penfold, C M; Bourke, J F; Chowdhury, M M U; Cooper, S M; Ghaffar, S; Green, C; Holden, C R; Johnston, G A; Mughal, A A; Reckling, C; Sabroe, R A; Stone, N M; Thompson, D; Wilkinson, S M; Buckley, D A

    2017-12-01

    There is a significant rate of sensitization worldwide to the oxidized fragrance terpenes limonene and linalool. Patch testing to oxidized terpenes is not routinely carried out; the ideal patch test concentration is unknown. To determine the best test concentrations for limonene and linalool hydroperoxides, added to the British baseline patch test series, to optimize detection of true allergy and to minimize irritant reactions. During 2013-2014, 4563 consecutive patients in 12 U.K. centres were tested to hydroperoxides of limonene in petrolatum (pet.) 0·3%, 0·2% and 0·1%, and hydroperoxides of linalool 1·0%, 0·5% and 0·25% pet. Irritant reactions were recorded separately from doubtful reactions. Concomitant reactions to other fragrance markers and clinical relevance were documented. Limonene hydroperoxide 0·3% gave positive reactions in 241 (5·3%) patients, irritant reactions in 93 (2·0%) and doubtful reactions in 110 (2·4%). Linalool hydroperoxide 1·0% gave positive reactions in 352 (7·7%), irritant reactions in 178 (3·9%) and doubtful reactions in 132 (2·9%). A total of 119 patients with crescendo reactions to 0·3% limonene would have been missed if only tested with 0·1% and 131 patients with crescendo reactions to 1·0% linalool would have been missed if only tested with 0·25%. In almost two-thirds of patients with positive patch tests to limonene and linalool the reaction was clinically relevant. The majority of patients did not react to any fragrance marker in the baseline series. We recommend that limonene hydroperoxides be tested at 0·3% and linalool hydroperoxides at 1·0% in the British baseline patch test series. © 2017 British Association of Dermatologists.

  4. Hydroxychloroquine-induced acute generalized exanthematous pustulosis with positive patch-testing.

    PubMed

    Charfi, Ons; Kastalli, Sarrah; Sahnoun, Rym; Lakhoua, Ghozlane

    2015-01-01

    Acute generalized exanthematous pustulosis (AGEP) is a severe cutaneous adverse reaction, mostly induced by drugs. Hydroxychloroquine have been rarely reported in literature as a causative drug of this reaction. We report a case of AGEP induced by hydroxychloroquine with systemic involvement and confirmed by positive patch testing.

  5. Patch test results with patients' own perfumes, deodorants and shaving lotions: results of the IVDK 1998-2002.

    PubMed

    Uter, W; Geier, J; Schnuch, A; Frosch, P J

    2007-03-01

    Assessment of the value of patch testing patients' own perfumes, eau de toilette, deodorants and shaving lotions with regard to diagnosing contact allergy to fragrances, and an analysis of the spectrum of concurrent patch test reactions to single fragrance allergens. Data of the Information Network of Departments of Dermatology (IVDK; http://www.ivdk.org) regarding patch test results with above products brought in by the patient, considered as possible cause of contact dermatitis, were retrospectively analysed. Between 1998 and 2002, 1468 patients were patch tested with 2557 single products (deodorants, n = 1094; eau de toilette, n = 598; perfume, n = 530; and pre- or after-shave, n = 325; remainder not classifiable), mostly 'as is'. Positive reactions were observed in 129 patients (to 191 products). In 58 of these patients, no further patch test reactions to the fragrance mix (FM-I), Myroxylon pereirae resin (balsam of Peru) or 4-(4-hydroxy-4-methyl-pentyl)-3-cyclohexencarboxaldehyde (e.g. Lyral(R)) were found. A strong association between contact sensitivity to the above commercial allergens and positive reactions to products was observed. Some single compounds such as ylang-ylang oil, propolis and especially oak moss absolute are important allergens in the 'perfume-positive' subgroup, but less in a subgroup positive to own deodorants. Patch testing this scope of products, brought in by the patient, can be regarded as a simple, safe and effective method to diagnose clinically relevant contact sensitization - the more so, as the composition of such products is ever-changing, and the sensitivity of established 'screening allergens' is thus insufficient.

  6. Insulin autoimmune syndrome caused by an adhesive skin patch containing loxoprofen-sodium.

    PubMed

    Okazaki-Sakai, Satoko; Yoshimoto, Sachiko; Yagi, Kunimasa; Wakasugi, Takanobu; Takeda, Yoshiyu; Yamagishi, Masakazu

    2013-01-01

    A 62-year-old woman complained of repeated hypoglycemic events. A 75 g oral glucose tolerance test (75 gOGTT) showed a marked increase in the plasma insulin level and impaired glucose tolerance. The patient exhibited a high titer of plasma anti-insulin autoantibodies. Her diagnosis was insulin autoimmune syndrome (IAS). Following the cessation of loxoprofen-sodium (LOXs), she experienced no further hypoglycemic episodes. However, the hypoglycemic attacks recurred following the accidental readministration of LOXs in an adhesive skin patch. Considering the changes in the titer of anti-insulin autoantibodies, the repeated 75 gOGTT and the repeated Scatchard analysis, we determined LOXs to be the cause of the IAS and evaluated the characteristics of the autoantibodies.

  7. Duct Leakage Repeatability Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the twomore » duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.« less

  8. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.

    PubMed

    Obermeyer, Robert J; Gaffar, Sheema; Kelly, Robert E; Kuhn, M Ann; Frantz, Frazier W; McGuire, Margaret M; Paulson, James F; Kelly, Cynthia S

    2018-02-01

    The aim of the study was to determine the role of patch metal allergy testing to select bar material for the Nuss procedure. An IRB-approved (11-04-WC-0098) single institution retrospective, cohort study comparing selective versus routine patch metal allergy testing to select stainless steel or titanium bars for Nuss repair was performed. In Cohort A (9/2004-1/2011), selective patch testing was performed based on clinical risk factors. In Cohort B (2/2011-9/2014), all patients were patch tested. The cohorts were compared for incidence of bar allergy and resultant premature bar loss. Risk factors for stainless steel allergy or positive patch test were evaluated. Cohort A had 628 patients with 63 (10.0%) selected for patch testing, while all 304 patients in Cohort B were tested. Over 10years, 15 (1.8%) of the 842 stainless steel Nuss repairs resulted in a bar allergy, and 5 had a negative preoperative patch test. The incidence of stainless steel bar allergy (1.8% vs 1.7%, p=0.57) and resultant bar loss (0.5% vs 1.3%, p=0.23) was not statistically different between cohorts. An allergic reaction to a stainless steel bar or a positive patch test was more common in females (OR=2.3, p<0.001) and patients with a personal (OR=24.8, p<0.001) or family history (OR=3.1, p<0.001) of metal sensitivity. Stainless steel bar allergies occur at a low incidence with either routine or selective patch metal allergy testing. If selective testing is performed, it is advisable in females and patients with a personal or family history of metal sensitivity. A negative preoperative patch metal allergy test does not preclude the possibility of a postoperative stainless steel bar allergy. Level III Treatment Study and Study of Diagnostic Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Patch test reactions to metal salts in patients with different types of dermatitis.

    PubMed

    Turčić, Petra; Marinović Kulišić, Sandra; Lipozenčić, Jasna

    2013-01-01

    Metal allergies can be a clinical problem, especially in atopic individuals. This study is unique and contributes with new knowledge in everyday life skin care of irritant and atopic dermatitis patients. The aim of the study was to determine the frequency of positive patch test reactions to metal contact allergens (potassium dichromate, cobalt chloride, nickel sulfate, white mercury precipitate) in patients diagnosed with allergic contact dermatitis, irritant contact dermatitis, and atopic dermatitis. Between 2007 and 2011, patch testing was performed in 2185 patients according to the International Contact Dermatitis Research Group technique. Study results showed statistically significant differences in patch test responses to 2 allergens, nickel sulfate (χ(2)=24.22; p<0.001) and cobalt chloride (χ(2)=22.72; p<0.001). Nickel sulfate was the most common allergen in allergic contact dermatitis and atopic dermatitis, while for irritant contact dermatitis the most common allergen was cobalt chloride. Among the 4 tested metal allergens, the most common and relevant was nickel sulfate (χ(2)=17.25; p<0.004), found in almost all study subjects. In conclusion, the increased awareness of allergens and their potential sources may help limit the use of these chemicals in consumer product manufacturing.

  10. Environmental contact factors in eczema and the results of patch testing Chinese patients with a modified European standard series of allergens.

    PubMed

    Li, Lin-Feng; Guo, Jing; Wang, Jing

    2004-07-01

    Environmental contact factors in eczema were investigated in China by clinical questionnaire and patch testing patients with a modified European standard series of allergens. 217 consecutive eczema patients were studied. Contact dermatitis (CD) was clinically diagnosed in 30% of the patients. Among the patients patch tested, 46 patients had clinically diagnosed allergic CD (ACD), 20 patients clinically had non-ACD (NACD) (including 16 cases of irritant contact dermatitis, 1 case of phototoxic contact reaction and 3 cases of asteatotic eczema) and 115 patients had clinically suspected ACD. 45 patients (98%) in the ACD group went on to have relevant patch test results. The most common ACD was from metals, fragrance materials, cosmetics and rubber materials. The most common contact allergens identified were nickel, fragrance mix, para-phenylenediamine (PPD), carba mix and thimerosal. No adverse reactions were observed to patch testing, except for pruritus in patch-test-positive patients. The positive rate of patch testing in ACD was much higher than that in NACD (98% versus 15%, P < 0.05, chi(2)-test). 60 (28%) patients had facial dermatitis (FD). Among these, 20 (33%) were confirmed as having ACD. 48 (22%) patients had hand dermatitis (HD). Among these, 7 (15%) were confirmed as having ACD. Fewer patients were confirmed as having ACD in the HD group than in the FD (15% versus 33%, P < 0.05, chi(2)-test). Although the difference was not significant, the total positivity rate in the HD group (55%) was lower than in the other groups. 65 (30%) patients had unclassified endogenous eczema (UEE). The total positive rate of patch testing in the UEE group (56%) was no different from that in the FD or HD groups. However, the relevance of positive patch tests was hard to determine in UEE. These results indicate that CD is common in eczema; relatively more patients with FD have ACD, while other factors, such as irritation, may play more of a role in HD. The total positive rate

  11. The Association of Race/Ethnicity and Patch Test Results: North American Contact Dermatitis Group, 1998-2006.

    PubMed

    Deleo, Vincent Anthony; Alexis, Andrew; Warshaw, Erin M; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel; Zug, Kathryn A; Belsito, Donald V; Fowler, Joseph F; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Rietschel, Robert L; Storrs, Frances J; Taylor, James S; Zirwas, Matthew

    2016-01-01

    The North American Contact Dermatitis Group patch tests patients with suspected allergic contact dermatitis (ACD) to a broad series of screening allergens and publishes periodic reports. We have previously reported on the association of race and ethnicity with the rates of positive responses to standard patch test allergens. This report extends those observations. The aim of the study was to report the North American Contact Dermatitis Group patch testing results from January 1, 1998, to December 31, 2006, comparing the frequency of positive reactions between white and black subjects. Standardized patch testing with 45 allergens was used at 13 centers in North America. χ analysis of results in black subjects as compared with whites was examined. A total of 19,457 patients were tested; 92.9% (17,803) were white and 7.1% (1,360) were black. The final diagnoses of ACD (whites, 45.9%; blacks, 43.6%) and irritant contact dermatitis (13.0%/13.3%) were similar in the 2 groups. The diagnosis of atopic dermatitis was less common in the white patients (8.9%) as compared with the black patients (13.3%). Positive patch test reactions rates were similar for most allergens. However, statistically, blacks reacted more frequently to p-phenylenediamine (7.0% vs 4.4%, P < 0.001), bacitracin (11.6% vs 8.3%, P = 0.0004), as well as specific rubber accelerators mercaptobenzothiazole (2.7% vs 1.8%), thiuram (6.2% vs 4.3%), and mercapto mix (1.9% vs 0.8%, P < 0.001). Whites had an increase in positive reactions to fragrances (12.12% vs 6.77%, P < 0.0001), formaldehyde (9.25% vs 5.45%, P < 0.0001), and some formaldehyde releaser preservatives used in personal care products and textile resins (9.80% vs 6.18%, P < 0.0001). There were statistically different rates of positive patch test reactions to specific allergens between black and white patients suspected of having ACD. The etiology of these differences is unclear but probably relates to culturally determined exposure patterns rather

  12. Common Allergens Identified Based on Patch Test Results in Patients with Suspected Contact Dermatitis of the Scalp

    PubMed Central

    Aleid, Nouf M.; Fertig, Raymond; Maddy, Austin; Tosti, Antonella

    2017-01-01

    Background Contact dermatitis of the scalp is common and might be caused by many chemicals including metals, ingredients of shampoos and conditioners, dyes, or other hair treatments. Eliciting a careful history and patch tests are necessary to identify the responsible allergen and prevent relapses. Objectives To identify allergens that may cause contact dermatitis of the scalp by reviewing patch test results. Methods We reviewed the records of 1,015 patients referred for patch testing at the Dermatology Department of the University of Miami. A total of 226 patients (205 females and 21 males) with suspected scalp contact dermatitis were identified, and the patch test results and clinical data for those patients were analyzed. Most patients were referred for patch testing from a specialized hair clinic at our institution. Results The most common allergens in our study population were nickel (23.8%), cobalt (21.0%), balsam of Peru (18.2%), fragrance mix (14.4%), carba mix (11.6%), and propylene glycol (PG) (8.8%). The majority of patients were females aged 40–59 years, and scalp itching or burning were reported as the most common symptom. Conclusion Frequent sources of allergens for metals include hair clasps, pins, and brushes, while frequent sources of allergens for preservatives, fragrance mix, and balsam of Peru include shampoos, conditioners, and hair gels. Frequent sources of allergens for PG include topical medications. PMID:28611994

  13. Contact Urticaria to Nickel: A Series of 11 Patients Who Were Prick Test Positive and Patch Test Negative to Nickel Sulfate 2.5% and 5.0.

    PubMed

    Saluja, Sandeep S; Davis, Crystal L; Chong, Tracie A; Powell, Douglas L

    2016-01-01

    Nickel is the most common allergen found by patch testing; however, not all cases of nickel allergy are type 4 (delayed) allergies. Contact urticaria (CU) to nickel (immediate reaction) has been reported; however, few seem to evaluate it as per a recent published survey of American Contact Dermatitis Society members. The aim of the study was to present a series of patients who had clinical histories suggestive of nickel allergy and yet were patch test negative but prick test positive to nickel, thus demonstrating CU. We reviewed the charts of 11 patients who were patch test negative but prick test positive. All 11 patients demonstrated evidence of CU by prick testing (or closed chamber test in 1). None were patch test positive to nickel 2.5% or 5.0%. Four patients' histories mentioned reactions to various jewelry/earrings within minutes, whereas 2 histories mentioned reacting within a few hours. These histories are consistent with CU. Others (except 1 patient) recalled reacting to jewelry/earrings but did not recall a time frame. Our series suggests that CU to nickel may be far more common than anticipated and should be evaluated with prick testing when patients' history suggests nickel allergy and yet they are patch test negative.

  14. Repeatability study of replicate crash tests: A signal analysis approach.

    PubMed

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2017-10-03

    To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test

  15. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    PubMed

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  16. Occupational allergic contact dermatitis and patch test results of leather workers at two Indonesian tanneries.

    PubMed

    Febriana, Sri Awalia; Jungbauer, Frank; Soebono, Hardyanto; Coenraads, Pieter-Jan

    2012-11-01

    Tannery workers are at considerable risk of developing occupational contact dermatitis. Occupational skin diseases in tannery workers in newly industrialized countries have been reported, but neither the prevalence of occupational allergic contact dermatitis nor the skin-sensitizing agents were specifically examined in those studies. To assess the prevalence of occupational allergic contact dermatitis in Indonesian tanneries, identify the causative allergens, and propose a tannery work series of patch test allergens. A cross-sectional study in all workers at two Indonesian tanneries was performed to assess the prevalence of occupational contact dermatitis via a questionnaire-based interview and skin examination. Workers with occupational contact dermatitis were patch tested to identify the causative allergens. Occupational contact dermatitis was suspected in 77 (16%) of the 472 workers. Thirteen (3%) of these 472 workers were confirmed to have occupational allergic contact dermatitis. Potassium dichromate (9.2%), N,N-diphenylguanidine (5.3%), benzidine (3.9%) and sodium metabisulfite (2.6%) were found to be the occupationally relevant sensitizers. The sensitization pattern showed some differences from the data in studies reported from other newly industrial countries. We compiled a 'tannery work series' of allergens for patch testing. A number of these allergens may also be considered for patch testing in patients with (leather) shoe dermatitis. © 2012 John Wiley & Sons A/S.

  17. Patch test standard series recommended by the Brazilian Contact Dermatitis Study Group during the 2006-2011 period.

    PubMed

    Duarte, Ida Alzira Gomes; Tanaka, Greta Merie; Suzuki, Nathalie Mie; Lazzarini, Rosana; Lopes, Andressa Sato de Aquino; Volpini, Beatrice Mussio Fornazier; Castro, Paulo Carrara de

    2013-01-01

    A retrospective study was carried out between 2006-2011. Six hundred and eighteen patients with suspected allergic contact dermatitis underwent the standard patch test series recommended by the Brazilian Contact Dermatitis Research Group. The aim of our study was to evaluate the variation of positive patch-test results from standard series year by year. The most frequently positive allergens were: nickel sulfate, thimerosal and potassium bichromate. Decrease of positive patch-test results over the years was statistically significant for: lanolin (p=0.01), neomycin (p=0.01) and anthraquinone (p=0.04). A follow-up study should be useful in determining which allergens could be excluded from standard series, as they may represent low sensitization risk.

  18. Ascorbate protects endothelial barrier function during septic insult: Role of protein phosphatase type 2A.

    PubMed

    Han, Min; Pendem, Suresh; Teh, Suet Ling; Sukumaran, Dinesh K; Wu, Feng; Wilson, John X

    2010-01-01

    Endothelial barrier dysfunction contributes to morbidity in sepsis. We tested the hypothesis that raising the intracellular ascorbate concentration protects the endothelial barrier from septic insult by inhibiting protein phosphatase type 2A. Monolayer cultures of microvascular endothelial cells were incubated with ascorbate, dehydroascorbic acid (DHAA), the NADPH oxidase inhibitors apocynin and diphenyliodonium, or the PP2A inhibitor okadaic acid and then were exposed to septic insult (lipopolysaccharide and interferon-gamma). Under standard culture conditions that depleted intracellular ascorbate, septic insult stimulated oxidant production and PP2A activity, dephosphorylated phosphoserine and phosphothreonine residues in the tight junction-associated protein occludin, decreased the abundance of occludin at cell borders, and increased monolayer permeability to albumin. NADPH oxidase inhibitors prevented PP2A activation and monolayer leak, showing that these changes required reactive oxygen species. Okadaic acid, at a concentration that inhibited PP2A activity and monolayer leak, prevented occludin dephosphorylation and redistribution, implicating PP2A in the response of occludin to septic insult. Incubation with ascorbate or DHAA raised intracellular ascorbate concentrations and mitigated the effects of septic insult. In conclusion, ascorbate acts within microvascular endothelial cells to inhibit septic stimulation of oxidant production by NADPH oxidase and thereby prevents PP2A activation, PP2A-dependent dephosphorylation and redistribution of occludin, and disruption of the endothelial barrier. Copyright 2009 Elsevier Inc. All rights reserved.

  19. [Patch testing and nickel allergy].

    PubMed

    Hansen, Sonali Rathour; Kroon, Susanne

    2008-02-14

    The prevalence of contact allergy varies between populations. 857 patients were tested for contact allergy (epicutantest; patch test) at the Department of Dermatology, Stavanger University Hospital in 2001 and 2002. Finn Chambers were placed on the upper part of the back, removed after 48 hrs and read after an additional 24 hrs. Positive reactions and other variables were recorded and data were collected retrospectively from journals. The most common allergens were metals such as nickel (nickel chloride; 40% and nickel sulphate; 23%), cobolt (11%) and dichromate (6.5%), fragrance mix (10%) and fragrance indicators such as peru balsam (9.4%), compositae (6.1%) and colophonium 5.3%. 370 (67%) women versus 139 (45%) men were positive for at least one of the allergens in the standard series (odds ratio 2.5 CI 1.83-3.23). 149 of 341 (44%) nickel positive patients had isolated reactions to nickel chloride without reacting to nickel sulphate, while only 11 (3.2%) reacted to nickel sulphate alone. 61/93 (66%) of the cobolt sensitive patients were also sensitive for nickel sulphate (OR: 8.9 CI 5.54-14.12,), while 77 (82%) tested positive for nickel chloride (OR: 9.26 CI 5.29-16.21). We detected a similar prevalence for common allergens as that reported from other skin departments in hospitals in Norway, but a higher average than that presented in other European studies.

  20. Patch testing with the European baseline series fragrance markers: a 2016 update.

    PubMed

    Ung, C Y; White, J M L; White, I R; Banerjee, P; McFadden, J P

    2018-03-01

    Fragrance contact allergy is common and is currently screened for using the following European baseline series fragrance markers: fragrance mix (FM)I, FMII, Myroxylon pereirae and hydroxyisohexyl 3-cyclohexene carboxaldehyde. To investigate the validity of patch testing using these fragrance markers in detecting fragrance allergy to 26 individual fragrance substances for which cosmetic ingredient labelling is mandatory within the European Union. We conducted a retrospective review of the patch test records of all patients with eczema who underwent testing using the European baseline series, extended with the individual fragrance substances during the period from 2015 to 2016. Overall, 359 patients (17·2%) reacted to one or more allergens from the labelled fragrance substance series and/or a fragrance marker from the European baseline series. The allergens that were positive with the greatest frequencies were oxidized linalool [n = 154; 7·4%, 95% confidence interval (CI) 6·3-8·6], oxidized limonene (n = 89; 4·3%, 95% CI 3·4-5·2) and Evernia furfuracea (n = 44; 2·1%, 95% CI 1·5-2·8). Of the 319 patients who reacted to any of the labelled fragrance substances, only 130 (40·8%) also reacted to a baseline series fragrance marker. The sensitivity of our history-taking for detecting fragrance allergy was 25·7%. Given the evolving trends in fragrance allergy, patch testing with FMI, FMII, M. pereirae and hydroxyisohexyl 3-cyclohexene carboxaldehyde is no longer sufficient for screening for fragrance allergy. © 2017 British Association of Dermatologists.

  1. Inferring local competition intensity from patch size distributions: a test using biological soil crusts

    USGS Publications Warehouse

    Bowker, Matthew A.; Maestre, Fernando T.

    2012-01-01

    Dryland vegetation is inherently patchy. This patchiness goes on to impact ecology, hydrology, and biogeochemistry. Recently, researchers have proposed that dryland vegetation patch sizes follow a power law which is due to local plant facilitation. It is unknown what patch size distribution prevails when competition predominates over facilitation, or if such a pattern could be used to detect competition. We investigated this question in an alternative vegetation type, mosses and lichens of biological soil crusts, which exhibit a smaller scale patch-interpatch configuration. This micro-vegetation is characterized by competition for space. We proposed that multiplicative effects of genetics, environment and competition should result in a log-normal patch size distribution. When testing the prevalence of log-normal versus power law patch size distributions, we found that the log-normal was the better distribution in 53% of cases and a reasonable fit in 83%. In contrast, the power law was better in 39% of cases, and in 8% of instances both distributions fit equally well. We further hypothesized that the log-normal distribution parameters would be predictably influenced by competition strength. There was qualitative agreement between one of the distribution's parameters (μ) and a novel intransitive (lacking a 'best' competitor) competition index, suggesting that as intransitivity increases, patch sizes decrease. The correlation of μ with other competition indicators based on spatial segregation of species (the C-score) depended on aridity. In less arid sites, μ was negatively correlated with the C-score (suggesting smaller patches under stronger competition), while positive correlations (suggesting larger patches under stronger competition) were observed at more arid sites. We propose that this is due to an increasing prevalence of competition transitivity as aridity increases. These findings broaden the emerging theory surrounding dryland patch size distributions

  2. Can exposure limitations for well-known contact allergens be simplified? An analysis of dose-response patch test data.

    PubMed

    Fischer, Louise Arup; Menné, Torkil; Voelund, Aage; Johansen, Jeanne Duus

    2011-06-01

    Allergic contact dermatitis is triggered by chemicals in the environment. Primary prevention is aimed at minimizing the risk of induction, whereas secondary and tertiary prevention are aimed at reducing elicitation. To identify the elicitation doses that will elicit an allergic reaction in 10% of allergic individuals under patch test conditions (ED(10) patch test) for different allergens, and to compare the results with those for different allergens and with animal data indicating sensitizing potency from the literature. The literature was searched for patch test elicitation studies that fulfilled six selected criteria. The elicitation doses were calculated, and fitted dose-response curves were drawn. Sixteen studies with eight different allergens-methylchloroisothiazolinone/ methylisothiazolinone, formaldehyde, nickel, cobalt, chromium, isoeugenol, hydroxyiso hexyl 3-cyclohexene carboxaldehyde, and methyldibromo glutaronitrile-were selected. The median ED(10) value was 0.835 µg/cm(2). The ED(10) patch test values were all within a factor of 7 from the lowest to the highest value, leaving out three outliers. No obvious patterns between the sensitization and elicitation doses for the allergens were found. We found a rather small variation in the ED(10) patch test between the allergens, and no clear relationship between induction potency and elicitation threshold of a range of allergens. This knowledge may stimulate thoughts on introducing a generic approach for limitations in exposure to well-known allergens. © 2011 John Wiley & Sons A/S.

  3. Assessment of hypoallergenicity of ten skincare products.

    PubMed

    Brandt, Staci; Lio, Peter

    2014-03-01

    Sensitive skin is a common skin complaint frequently associated with skin diseases or adverse reactions to cosmetic products. Manufacturers have produced numerous products targeted for patients with sensitive skin and frequently label these products as being hypoallergenic. This term implies that the product may be less likely to cause an allergic reaction and be better suited for those with sensitive skin. However, there is no federal regulatory definition of this term and products may not have clinical support of their claim. Patch testing ingredients is frequently done to identify potential irritants; however, patch-testing product formulations may provide more realistic expectations about potential skin sensitivity and help support claims of hypoallergenicity. Ten skincare products were assessed for their sensitizing potential and hypoallergenicity in 14 repeat insult patch test clinical studies, involving over 2,000 subjects. In these studies, the products were deemed to be hypoallergenic if there was no evidence of sensitization or allergic reactions. The results from these trials demonstrated that all ten products were well tolerated, showed no sensitization or allergic reactions, and support claims of hypoallergenicity.

  4. Patch testing and cross sensitivity study of adverse cutaneous drug reactions due to anticonvulsants: A preliminary report.

    PubMed

    Shiny, T N; Mahajan, Vikram K; Mehta, Karaninder S; Chauhan, Pushpinder S; Rawat, Ritu; Sharma, Rajni

    2017-03-26

    To evaluate the utility of patch test and cross-sensitivity patterns in patients with adverse cutaneous drug reactions (ACDR) from common anticonvulsants. Twenty-four (M:F = 13:11) patients aged 18-75 years with ACDR from anticonvulsants were patch tested 3-27 mo after complete recovery using carbamazepine, phenytoin, phenobarbitone, lamotrigine, and sodium valproate in 10%, 20% and 30% conc. in pet. after informed consent. Positive reactions persisting on D3 and D4 were considered significant. Clinical patterns were exanthematous drug rash with or without systemic involvement (DRESS) in 18 (75%), Stevens-Johnsons syndrome/toxic epidermal necrolysis (SJS/TEN) overlap and TEN in 2 (8.3%) patients each, SJS and lichenoid drug eruption in 1 (4.2%) patient each, respectively. The implicated drugs were phenytoin in 14 (58.3%), carbamazepine in 9 (37.5%), phenobarbitone in 2 (8.3%), and lamotrigine in 1 (4.7%) patients, respectively. Twelve (50%) patients elicited positive reactions to implicated drugs; carbamazepine in 6 (50%), phenytoin alone in 4 (33.3%), phenobarbitone alone in 1 (8.3%), and both phenytoin and phenobarbitone in 1 (8.33%) patients, respectively. Cross-reactions occurred in 11 (92%) patients. Six patients with carbamazepine positive patch test reaction showed cross sensitivity with phenobarbitone, sodium valproate and/or lamotrigine. Three (75%) patients among positive phenytoin patch test reactions had cross reactions with phenobarbitone, lamotrigine, and/or valproate. Carbamazepine remains the commonest anticonvulsant causing ACDRs and cross-reactions with other anticonvulsants are possible. Drug patch testing appears useful in DRESS for drug imputability and cross-reactions established clinically.

  5. Patch testing and cross sensitivity study of adverse cutaneous drug reactions due to anticonvulsants: A preliminary report

    PubMed Central

    Shiny, T N; Mahajan, Vikram K; Mehta, Karaninder S; Chauhan, Pushpinder S; Rawat, Ritu; Sharma, Rajni

    2017-01-01

    AIM To evaluate the utility of patch test and cross-sensitivity patterns in patients with adverse cutaneous drug reactions (ACDR) from common anticonvulsants. METHODS Twenty-four (M:F = 13:11) patients aged 18-75 years with ACDR from anticonvulsants were patch tested 3-27 mo after complete recovery using carbamazepine, phenytoin, phenobarbitone, lamotrigine, and sodium valproate in 10%, 20% and 30% conc. in pet. after informed consent. Positive reactions persisting on D3 and D4 were considered significant. RESULTS Clinical patterns were exanthematous drug rash with or without systemic involvement (DRESS) in 18 (75%), Stevens-Johnsons syndrome/toxic epidermal necrolysis (SJS/TEN) overlap and TEN in 2 (8.3%) patients each, SJS and lichenoid drug eruption in 1 (4.2%) patient each, respectively. The implicated drugs were phenytoin in 14 (58.3%), carbamazepine in 9 (37.5%), phenobarbitone in 2 (8.3%), and lamotrigine in 1 (4.7%) patients, respectively. Twelve (50%) patients elicited positive reactions to implicated drugs; carbamazepine in 6 (50%), phenytoin alone in 4 (33.3%), phenobarbitone alone in 1 (8.3%), and both phenytoin and phenobarbitone in 1 (8.33%) patients, respectively. Cross-reactions occurred in 11 (92%) patients. Six patients with carbamazepine positive patch test reaction showed cross sensitivity with phenobarbitone, sodium valproate and/or lamotrigine. Three (75%) patients among positive phenytoin patch test reactions had cross reactions with phenobarbitone, lamotrigine, and/or valproate. CONCLUSION Carbamazepine remains the commonest anticonvulsant causing ACDRs and cross-reactions with other anticonvulsants are possible. Drug patch testing appears useful in DRESS for drug imputability and cross-reactions established clinically. PMID:28396847

  6. PATIENTS' KNOWLEDGE OF MEDICAL PATCHES IN HUNGARY.

    PubMed

    Somogyi, Orsolya; Zelko, Romana

    2016-11-01

    Transdermal therapy with medical patches is a simple possibility in home medication. As the correct use of patches has a decisive impact from the point of its modulator effect.A questionnaire survey was developed to explore level of patients' knowledge of the correct use of transdermal patches. A survey was administered in thirteen Hungarian community pharmacies from October of 2012 to May of 2015. Most of the participants, men and women over 18 years of age (n = 233), used major analgesic patches (fentanyl); the remainder were given nitroglycerin, NSAID analgesics patches during the survey. For the hypothesis testing it was assumed that men were more likely to use a razor for skin depilation before patch application than women as their denser pelage hinders patch adhesion. The hypothesis testing showed no significant gender difference in razor use (X² = 0.201; p = 0.654). Pharmacists should direct patients to avoid using soap for skin cleansing before patch application because only 22 percent of the participants always avoided its use. Since only 9 tests were flawless from 233 completed questionnaires. Many patients do not understand how to correctly apply a transdermal dosage patch. Pharmacists should teach their correct application based on results.

  7. Patch testing and allergen-specific serum IgE and IgG antibodies in the diagnosis of canine adverse food reactions.

    PubMed

    Bethlehem, Simone; Bexley, Jennifer; Mueller, Ralf S

    2012-02-15

    Adverse food reaction (AFR) is a common differential diagnosis for pruritic dogs. The only way to diagnose AFR is an elimination diet of 6-8 weeks with a protein and a carbohydrate source not previously fed. In humans, patch testing has been shown to be a useful tool to diagnose food allergies. In veterinary medicine, serum food allergen-specific antibody testing is widely offered to identify suitable ingredients for such diets. The aim of this study was to determine sensitivity, specificity, negative and positive predictability of patch testing with and serum antibody testing for a variety of common food stuffs. Twenty-five allergic dogs underwent an elimination diet and individual rechallenge with selected food stuffs, food patch testing and serum testing for food-antigen specific IgE and IgG. Eleven clinically normal control dogs only were subjected to patch and serum testing. The sensitivity and specificity of the patch test were 96.7 and 89.0% respectively, negative and positive predictability were 99.3 and 63.0%. For IgE and IgG the sensitivity was 6.7 and 26.7%, specificity were 91.4 and 88.3%, the negative predictive values 80.7 and 83.7% and the positive predictive values were 15.4 and 34.8%. Based on these results, a positive reaction of a dog on these tests is not very helpful, but a negative result indicates that this antigen is tolerated well. We conclude that patch testing (and to a lesser degree serum testing) can be helpful in choosing ingredients for an elimination diet in a dog with suspected AFR. Copyright © 2012. Published by Elsevier B.V.

  8. Atopy patch tests in young adult patients with atopic dermatitis and controls: dose-response relationship, objective reading, reproducibility and clinical interpretation.

    PubMed

    Bygum, Anette; Mortz, Charlotte Gotthard; Andersen, Klaus Ejner

    2003-01-01

    The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants were retested after 6 weeks. Ten of 19 (53%) evaluable patients with atopic dermatitis had at least one positive atopy patch test. However, there was no clear clinical relevance of the atopy patch test results when related to patient history and distribution of dermatitis. Reproducible and dose-dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss and erythema, while measurement of capacitance did not distinguish between positive and negative reactions. The results of the present study do not support the routine use of atopy patch tests in the evaluation of adult patients with atopic dermatitis.

  9. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions.

    PubMed

    Mose, Kristian F; Andersen, Klaus E; Christensen, Lars Porskjaer

    2012-04-01

    Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different storage conditions. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport container) at room temperature and in a refrigerator. The samples were analysed in triplicate with high-performance liquid chromatography. The decrease in concentration was substantial for all five allergens under both storage conditions in IQ chamber™ and IQ Ultimate™, with the exception of 2-HEMA during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens. © 2012 John Wiley & Sons A/S.

  10. Our experiences with the use of atopy patch test in the diagnosis of cow's milk hypersensitivity.

    PubMed

    Pustisek, Nives; Jaklin-Kekez, Alemka; Frkanec, Ruza; Sikanić-Dugić, Nives; Misak, Zrinjka; Jadresin, Oleg; Kolacek, Sanja

    2010-01-01

    Atopy patch test has been recognized as a diagnostic tool for the verification of food allergies in infants and small children suffering from atopic dermatitis. The test also has a role in the diagnosis of food allergies characterized by clinical signs associated with the digestive system. Yet, in spite of numerous studies, the test itself has hitherto not been standardized. Our study enlisted 151 children less than two years of age, who exhibited suspect skin and/or gastrointestinal manifestations of food allergy to cow's milk, and in whom tests failed to prove early type of allergic reaction. Atopy patch test was positive in 28% of the children with atopic dermatitis, 43% of the children with suspect gastrointestinal manifestation and 32% of the children with skin and gastrointestinal manifestations of food allergy. In our experience, atopy patch test is an excellent addition to the hitherto used tests for the diagnosis of food allergies. It targets specifically delayed type hypersensitivity reactions, which are difficult to confirm with other diagnostic tools. It is furthermore simple to perform, noninvasive and produces a minimum of undesired side effects. For these reasons, it should become part of the routine diagnostic toolset for food allergies to cow's milk in infants and children, and applied before a food challenge test.

  11. Multicentre patch testing with a resol resin based on phenol and formaldehyde.

    PubMed

    Isaksson, Marléne; Inerot, Annica; Lidén, Carola; Matura, Mihaly; Stenberg, Berndt; Möller, Halvor; Bruze, Magnus

    2011-07-01

    Contact allergy to phenol-formaldehyde resins (PFRs) based on phenol and formaldehyde is not detected by a p-tertiary-butylphenol-formaldehyde resin (PTBP-FR) included in most baseline patch test series. To investigate the rate of contact allergy to PFR-2 (a mixture of monomers and dimers from a resol resin based on phenol and formaldehyde) in a Swedish population, and to investigate associated simultaneous allergic reactions. Five centres representing the Swedish Contact Dermatitis Research Group included PFR-2 in their patch test baseline series for a period of 1.5 years. Of 2504 patients tested, 27 (1.1%) reacted to PFR-2. Of those 27 individuals, 2 had a positive reaction to formaldehyde and 2 to PTBP-FR. Simultaneous allergic reactions were noted to colophonium in 6, to Myroxylon pereirae in 14, and to fragrance mix I in 15. The contact allergy frequency in the tested population (1.1%) merits its inclusion in the Swedish baseline series and possibly also in other baseline series. Simultaneous allergic reactions were noted to colophonium, M. pereirae, and fragrance mix I. © 2011 John Wiley & Sons A/S.

  12. Cross-reactions among parabens, para-phenylenediamine, and benzocaine: a retrospective analysis of patch testing.

    PubMed

    Turchin, Irina; Moreau, Linda; Warshaw, Erin; Sasseville, Denis

    2006-12-01

    Parabens are alkyl ester derivatives of para-hydroxybenzoic acid and are the most commonly used preservatives in the cosmetic industry. Cross-reactions with para-amino compounds, namely, benzocaine and para-phenylenediamine (PPD), have been reported but are thought to be extremely rare. To evaluate the rate of cross-reactivity between parabens, PPD, and benzocaine in a population of patients patch-tested in a hospital-based contact dermatitis clinic. A retrospective analysis of 4,368 patients consecutively patch-tested between July 1989 and June 2005. Our study demonstrated that the rate of cross-reactions to parabens in PPD- and benzocaine-positive patients combined is 2%. This cross-reaction rate is significant in the tested population but still falls within the previously reported rates of sensitivity to parabens in the general population (0 to 3.5%).

  13. On the Persistent Shape and Coherence of Pulsating Auroral Patches

    NASA Astrophysics Data System (ADS)

    Humberset, B. K.; Gjerloev, J. W.; Mann, I. R.; Michell, R. G.; Samara, M.

    2018-05-01

    The pulsating aurora covers a broad range of fluctuating shapes that are poorly characterized. The purpose of this paper is therefore to provide objective and quantitative measures of the extent to which pulsating auroral patches maintain their shape, drift and fluctuate in a coherent fashion. We present results from a careful analysis of pulsating auroral patches using all-sky cameras. We have identified four well-defined individual patches that we follow in the patch frame of reference. In this way we avoid the space-time ambiguity which complicates rocket and satellite measurements. We find that the shape of the patches is remarkably persistent with 85-100% of the patch being repeated for 4.5-8.5 min. Each of the three largest patches has a temporal correlation with a negative dependence on distance, and thus does not fluctuate in a coherent fashion. A time-delayed response within the patches indicates that the so-called streaming mode might explain the incoherency. The patches appear to drift differently from the SuperDARN-determined E→×B→ convection velocity. However, in a nonrotating reference frame the patches drift with 230-287 m/s in a north eastward direction, which is what typically could be expected for the convection return flow.

  14. Fatigue-enhanced hyperalgesia in response to muscle insult: induction and development occur in a sex-dependent manner

    PubMed Central

    Gregory, N. S.; Gibson-Corley, K.; Frey-Law, L.; Sluka, K. A.

    2014-01-01

    Chronic muscle pain affects 20–50% of the population, is more common in women than men, and is associated with increased pain during physical activity and exercise. Muscle fatigue is common in people with chronic muscle pain, occurs in response to exercise and is associated with release of fatigue metabolites. Fatigue metabolites can sensitize muscle nociceptors which could enhance pain with exercise. Using a mouse model we tested whether fatigue of a single muscle, induced by electrical stimulation, resulted in enhanced muscle hyperalgesia and if the enhanced hyperalgesia was more pronounced in female mice. Muscle fatigue was induced in combination with a sub-threshold muscle insult (2 injections of pH 5.0 saline) in male and female mice. We show that male and female mice, fatigued immediately prior to muscle insult in the same muscle, develop similar muscle hyperalgesia 24h later. However, female mice also develop hyperalgesia when muscle fatigue and muscle insult occur in different muscles, and when muscle insult is administered 24 hours after fatigue in the same muscle. Further, hyperalgesia lasts significantly longer in females. Finally, muscle insult with or without muscle fatigue results in minimal inflammatory changes in the muscle itself, and sex differences are not related to estradiol (ovariectomy) or changes in brainstem activity (pNR1). Thus, the current model mimics muscle fatigue-induced enhancement of pain observed in chronic muscle pain conditions in the human population. Interactions between fatigue and muscle insult may underlie the development of chronic widespread pain with an associated female predominance observed in human subjects. PMID:23906552

  15. North American contact dermatitis group patch test results: 2011-2012.

    PubMed

    Warshaw, Erin M; Maibach, Howard I; Taylor, James S; Sasseville, Denis; DeKoven, Joel G; Zirwas, Matthew J; Fransway, Anthony F; Mathias, C G Toby; Zug, Kathryn A; DeLeo, Vincent A; Fowler, Joseph F; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Belsito, Donald V

    2015-01-01

    Patch testing is an important diagnostic tool for assessment of allergic contact dermatitis (ACD). This study documents the North American Contact Dermatitis Group (NACDG) patch-testing results from January 1, 2011, to December 31, 2012. At 12 centers in North America, patients were tested in a standardized manner with a series of 70 allergens. Data were manually verified and entered into a central database. Descriptive frequencies were calculated, and trends analyzed using χ statistics. Four thousand two hundred thirty-eight patients were tested; of these, 2705 patients (63.8%) had at least 1 positive reaction, and 2029 (48.0%) were ultimately determined to have a primary diagnosis of ACD. Four hundred eight patients (9.6%) had occupationally related skin disease. There were 7532 positive allergic reactions. As compared with previous reporting periods (2009-2010 and 2000-2010), positive reaction rates statistically increased for 6 allergens: methylchloroisothiazolinone/methylisothiazolinone (5.0%; risk ratios [RRs]: 2.01 [1.60-2.52], 1.87 [1.61-2.18]), lanolin alcohol (4.6%; RRs 1.83 [1.45-2.30], 2.10 [1.79-2.47]), cinnamic aldehyde (3.9%; 1.69 [1.32-2.15], 1.53 [1.28-1.82]), glutaral (1.5%; 1.67 [1.13-2.48], 1.31 [1.00-1.71]), paraben mix (1.4%; 1.77 [1.16-2.69], 1.44 [1.09-1.92]), and fragrance mix I (12.1%; RRs 1.42 [1.25-1.61], 1.24 [1.14-1.36]). Compared with the previous decade, positivity rates for all formaldehyde-releasing preservatives significantly decreased (formaldehyde 6.6%; RR, 0.82 [0.73, 0.93]; quaternium-15 6.4% RR 0.75 [0.66, 0.85]; diazolidinyl urea 2.1%; RR, 0.67 [0.54, 0.84]; imidazolidinyl urea 1.6%, 0.60 [0.47, 0.77]; bronopol 1.6%; RR, 0.60 [0.46, 0.77]; DMDM hydantoin 1.6%; RR, 0.59 [0.54, 0.84]). Approximately a quarter of patients had at least 1 relevant allergic reaction to a non-NACDG allergen. In addition, approximately one-fourth to one-third of reactions detected by NACDG allergens would have been hypothetically missed by T

  16. Repeatability of a dynamic rollover test system.

    PubMed

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2016-08-17

    The goal of this study was to characterize the rollover crash and to evaluate the repeatability of the Dynamic Rollover Test System (DRoTS) in terms of initial roof-to-ground contact conditions, vehicle kinematics, road reaction forces, and vehicle deformation. Four rollover crash tests were performed on 2 pairs of replicate vehicles (2 sedan tests and 2 compact multipurpose van [MPV] tests), instrumented with a custom inertial measurement unit to measure vehicle and global kinematics and string potentiometers to measure pillar deformation time histories. The road was instrumented with load cells to measure reaction loads and an optical encoder to measure road velocity. Laser scans of pre- and posttest vehicles were taken to provide detailed deformation maps. Initial conditions were found to be repeatable, with the largest difference seen in drop height of 20 mm; roll rate, roll angle, pitch angle, road velocity, drop velocity, mass, and moment of inertia were all 7% different or less. Vehicle kinematics (roll rate, road speed, roll and pitch angle, global Z' acceleration, and global Z' velocity) were similar throughout the impact; however, differences were seen in the sedan tests because of a vehicle fixation problem and differences were seen in the MPV tests due to an increase in reaction forces during leading side impact likely caused by disparities in roll angle (3° difference) and mass properties (2.2% in moment of inertia [MOI], 53.5 mm difference in center of gravity [CG] location). Despite those issues, kinetic and deformation measures showed a high degree of repeatability, which is necessary for assessing injury risk in rollover because roof strength positively correlates with injury risk (Brumbelow 2009). Improvements of the test equipment and matching mass properties will ensure highly repeatable initial conditions, vehicle kinematics, kinetics, and deformations.

  17. Results of tests of K5NA and a revised formulation of EPDM/cork patch material in MSFC Hot Gas Facility

    NASA Technical Reports Server (NTRS)

    Dean, W. G.

    1982-01-01

    During prelaunch procedures at Kennedy Space Center some of the EPDM Thermal Protection System material was damaged on the Solid Rocket Booster stiffener stubs. The preferred solution was to patch the damaged areas with a cork-filled epoxy patching compound. Before this was done, however, it was requested that this patching technique be checked out by testing it in the MSFC Hot Gas Facility. Two tests were run in the HFG in 1980. The results showed the patch material to be adequate. Since that time, the formulation of the cork-filled epoxy material has been changed. It became necessary to retest this concept to be sure that the new material is as good as or better than the original material. In addition to the revised formulation material, tests were also made using K5NA as the patch material. The objectives of the tests reported herein were to: (1) compare the thermal performance of the original and the new cork-filled epoxy formulations, and (2) compare the K5NA closeout material to these epoxy materials. Material specifications are also discussed.

  18. Occupationally related contact dermatitis in North American food service workers referred for patch testing, 1994 to 2010.

    PubMed

    Warshaw, Erin M; Kwon, Gina P; Mathias, C G Toby; Maibach, Howard I; Fowler, Joseph F; Belsito, Donald V; Sasseville, Denis; Zug, Kathryn A; Taylor, James S; Fransway, Anthony F; Deleo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Zirwas, Matthew J; Dekoven, Joel G

    2013-01-01

    Contact dermatoses are common in food service workers (FSWs). This study aims to (1) determine the prevalence of occupationally related contact dermatitis among FSWs patch tested by the North American Contact Dermatitis Group (NACDG) and (2) characterize responsible allergens and irritants as well as sources. Cross-sectional analysis of patients patch tested by the NACDG, 1994 to 2010, was conducted. Of 35,872 patients patch tested, 1237 (3.4%) were FSWs. Occupationally related skin disease was significantly more common in FSWs when compared with employed non-FSWs. Food service workers were significantly more likely to have hand (P < 0.0001) and arm (P < 0.0006) involvement. The rates for irritant and allergic contact dermatitis in FSWs were 30.6% and 54.7%, respectively. Although the final diagnosis of irritant contact dermatitis was statistically higher in FSWs as compared with non-FSWs, allergic contact dermatitis was lower in FSWs as compared with non-FSWs. The most frequent currently relevant and occupationally related allergens were thiuram mix (32.5%) and carba mix (28.9%). Gloves were the most common source of responsible allergens. The NACDG standard tray missed at least 1 occupationally related allergen in 38 patients (4.3%). Among FSWs patch tested by the NACDG between 1994 and 2010, the most common allergens were thiuram mix and carba mix. Gloves were the most common source of responsible allergens.

  19. Water Quality Criteria for Colored Smokes: Solvent Yellow 33

    DTIC Science & Technology

    1987-11-01

    Y . ’~ ~% d .’ 4’ . TABLE 4. DISTRIBUTION OF [1 4 C]-SOLVENT YELLOW 33 IN RATS 1 hr AFTER- EXPOSURE TO SOLVENT YELLOW 33 (SY) OR SOLVENT YELLOW 33...have shown that some individuals react strongly Lo this dye. The repeat insult patch test is used most often. The subjects receive five to ten exposures...70 Neutrophils Control 5 ± 2 0 ± 0 7 ± 3 3( lO cells/g) Exposed 1300 ± 130 d 470 ± i 0 0d 290 ± 50 d a. Adapted from Henderson et al. 1985b. b. Values

  20. Severe allergic reactions to para-phenylenediamine in children and adolescents: should the patch test concentration of PPD be changed?

    PubMed

    Spornraft-Ragaller, Petra; Kämmerer, Eva; Gillitzer, Claus; Schmitt, Jochen

    2012-04-01

    Semipermanent henna tattoos containing para-phenylenediamine (PPD) are a well-known cause of severe contact dermatitis, mainly in children. Another relevant exposure source to PPD are hair dyes, which are increasingly used by children and have also been reported to cause intense facial and scalp dermatitis. German patch test guidelines for children recommend that PPD should only be tested in patients who have had a henna tattoo, and then at a reduced concentration of PPD 0.5 % for 24 hours. We report on patch test results in four patients, three children and one adolescent, with a history of contact dermatitis to henna tattoos or hair dye. We used the recommended or even lower patch test concentrations of PPD with 24-hours exposure in all patients. All patients showed very strong patch test reactions to PPD and cross-reactions to related compounds even after dilution of PPD to as low as 0.05 %. Therefore, we suggest that in children with a history of allergic reactions to this compound, a titration test should be performed beginning at a concentration of maximal 0.05 %. This procedure has also been proposed previously based on a larger cases series in adults. © The Authors • Journal compilation © Blackwell Verlag GmbH, Berlin.

  1. Initial Characterization of a Gel Patch Dosimeter for In Vivo Dosimetry

    PubMed Central

    Matrosic, C; Culberson, W; Rosen, B; Madsen, E; Frank, G; Bednarz, B

    2016-01-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6%T normoxic polyacrylamide gel, was injected into 1-cm thick acrylic molds to create 1-cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose response of all three batches of gel was found to be linear within the range of 2–20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  2. Initial characterization of a gel patch dosimeter for in vivo dosimetry

    NASA Astrophysics Data System (ADS)

    Matrosic, C.; Culberson, W.; Rosen, B.; Madsen, E.; Frank, G.; Bednarz, B.

    2016-05-01

    In vivo dosimetry is a greatly underutilized tool for patient safety in clinical external beam radiotherapy treatments, despite being recommended by several national and international organizations (AAPM, ICRU, IAEA, NACP). The reasons for this underutilization mostly relate to the feasibility and cost of in vivo dosimetry methods. Due to the increase in the number of beam angles and dose per fraction in modern treatments, there is a compelling need for a novel dosimeter that is robust and affordable while able to operate properly in these complex conditions. This work presents a gel patch dosimeter as a novel method of in vivo dosimetry. DEFGEL, a 6% T normoxic polyacrylamide gel, was injected into 1 cm thick acrylic molds to create 1 cm thick small cylindrical patch dosimeters. To evaluate the change in optical density due to radiation induced polymerization, dosimeters were scanned before and after irradiation using an in-house developed laser densitometer. The dose-responses of three separate batches of gel were evaluated and compared to check for linearity and repeatability. The response development time was evaluated to ensure that the patch dosimeter could be high throughput. Additionally, the potential of this system to be used as an in vivo dosimeter was tested with a clinically relevant end-to-end in vivo phantom test. All irradiations were performed with a Varian Clinac 21EX at the University of Wisconsin Medical Radiation Research Center (UWMRRC). The dose-response of all three batches of gel was found to be linear within the range of 2-20 Gy. At doses below 0.5 Gy the statistical uncertainties were prohibitively large to make quantitative assessments of the results. The three batches demonstrated good repeatability in the range of 2 Gy to up to 10 Gy, with only slight variations in response at higher doses. For low doses the dosimeter fully developed within an hour while at higher doses they fully developed within four hours. During the in vivo

  3. Multicenter Patch Testing With Methylchloroisothizoline/Methylisothiazolinone in 100 and 200 ppm Within the International Contact Dermatitis Research Group.

    PubMed

    Engfeldt, Malin; Ale, Iris; Andersen, Klaus E; Elsner, Peter; Goh, Chee-Leok; Goossens, An; Jerajani, Hemangi; Matsunaga, Kayoko; Bruze, Magnus

    The preservative methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) is a well-known contact sensitizer. Historically, there have been different opinions on the optimal patch test concentration of MCI/MI, and both 0.01% and 0.02% aqueous (aq.) have been proposed. In 2011, based on literature reviews, it was recommended that the concentration of 0.02% aq. should be used in the international baseline series. The aim of this study was to verify the recommendation from 2011 by comparing the patch test results from consecutive patch testing with MCI/MI 0.01% and 0.02% in clinics representing countries around the world. Two thousand seven hundred three consecutive patients with dermatitis in 8 dermatology clinics representing 8 countries were patch tested with MCI/MI 0.01% aq. and, in parallel with MCI/MI 0.02% aq., provisionally included in the baseline series. Contact allergy to MCI/MI at 0.01% and 0.02% was found in 3.7% and 5.6% of the patients, respectively (P < 0.001). Methylchloroisothiazolinone/MI 0.02% aq. (dose, 6 μg/cm) diagnoses significantly more contact allergy than 0.01% (dose, 3 μg/cm), without resulting in more adverse reactions. Methylchloroisothiazolinone/MI at 0.02% aq. should therefore be continuously used in the international baseline series.

  4. Children's Executive Functions: Are They Poorer after Very Early Brain Insult

    ERIC Educational Resources Information Center

    Anderson, Vicki; Spencer-Smith, Megan; Coleman, Lee; Anderson, Peter; Williams, Jackie; Greenham, Mardee; Leventer, Richard J.; Jacobs, Rani

    2010-01-01

    Traditionally early brain insult (EBI) has been considered to have better outcome than later injury, consistent with the notion that the young brain is flexible and able to reorganize. Recent research findings question this view, suggesting that EBI might lead to poorer outcome than brain insult at any other age. Exploring this early vulnerability…

  5. Epigenetic Regulation of Autism-Associated Genes by Environmental Insults: Novel Associations

    DTIC Science & Technology

    2009-08-01

    TITLE: Epigenetic Regulation of Autism -Associated Genes by Environmental Insults: Novel Associations PRINCIPAL INVESTIGATOR: Daryl Spinner Ph.D...SUBTITL Epigenetic regulation of Autism -associated genes by environmental insults: Novel associations 5a. CONTRACT NUMBER 5b. GRANT NUMBER...environmental-induced cases of autism . Accordingly, we established mouse embryonic cortical cultures of neurons and astrocytes, and exposed them to commonly

  6. Shear sensing based on a microstrip patch antenna

    NASA Astrophysics Data System (ADS)

    Mohammad, I.; Huang, H.

    2012-10-01

    A microstrip patch antenna sensor was studied for shear sensing with a targeted application of measuring plantar shear distribution on a diabetic foot. The antenna shear sensor consists of three components, namely an antenna patch, a soft foam substrate and a slotted ground plane. The resonant frequency of the antenna sensor is sensitive to the overlapping length between the slot in the ground plane and the antenna patch. A shear force applied along the direction of the slot deforms the foam substrate and causes a change in the overlapping length, which can be detected from the antenna frequency shift. The antenna shear sensor was designed based on simulated antenna frequency response and validated by experiments. Experimental results indicated that the antenna sensor exhibits high sensitivity to shear deformation and responds to the applied shear loads with excellent linearity and repeatability.

  7. Social Familiarity Governs Prey Patch-Exploitation, - Leaving and Inter-Patch Distribution of the Group-Living Predatory Mite Phytoseiulus persimilis

    PubMed Central

    Zach, Gernot J.; Peneder, Stefan; Strodl, Markus A.; Schausberger, Peter

    2012-01-01

    Background In group-living animals, social interactions and their effects on other life activities such as foraging are commonly determined by discrimination among group members. Accordingly, many group-living species evolved sophisticated social recognition abilities such as the ability to recognize familiar individuals, i.e. individuals encountered before. Social familiarity may affect within-group interactions and between-group movements. In environments with patchily distributed prey, group-living predators must repeatedly decide whether to stay with the group in a given prey patch or to leave and search for new prey patches and groups. Methodology/Principal Findings Based on the assumption that in group-living animals social familiarity allows to optimize the performance in other tasks, as for example predicted by limited attention theory, we assessed the influence of social familiarity on prey patch exploitation, patch-leaving, and inter-patch distribution of the group-living, plant-inhabiting predatory mite Phytoseiulus persimilis. P. persimilis is highly specialized on herbivorous spider mite prey such as the two-spotted spider mite Tetranychus urticae, which is patchily distributed on its host plants. We conducted two experiments with (1) groups of juvenile P. persimilis under limited food on interconnected detached leaflets, and (2) groups of adult P. persimilis females under limited food on whole plants. Familiar individuals of both juvenile and adult predator groups were more exploratory and dispersed earlier from a given spider mite patch, occupied more leaves and depleted prey more quickly than individuals of unfamiliar groups. Moreover, familiar juvenile predators had higher survival chances than unfamiliar juveniles. Conclusions/Significance We argue that patch-exploitation and -leaving, and inter-patch dispersion were more favorably coordinated in groups of familiar than unfamiliar predators, alleviating intraspecific competition and improving prey

  8. Social familiarity governs prey patch-exploitation, -leaving and inter-patch distribution of the group-living predatory mite Phytoseiulus persimilis.

    PubMed

    Zach, Gernot J; Peneder, Stefan; Strodl, Markus A; Schausberger, Peter

    2012-01-01

    In group-living animals, social interactions and their effects on other life activities such as foraging are commonly determined by discrimination among group members. Accordingly, many group-living species evolved sophisticated social recognition abilities such as the ability to recognize familiar individuals, i.e. individuals encountered before. Social familiarity may affect within-group interactions and between-group movements. In environments with patchily distributed prey, group-living predators must repeatedly decide whether to stay with the group in a given prey patch or to leave and search for new prey patches and groups. Based on the assumption that in group-living animals social familiarity allows to optimize the performance in other tasks, as for example predicted by limited attention theory, we assessed the influence of social familiarity on prey patch exploitation, patch-leaving, and inter-patch distribution of the group-living, plant-inhabiting predatory mite Phytoseiulus persimilis. P. persimilis is highly specialized on herbivorous spider mite prey such as the two-spotted spider mite Tetranychus urticae, which is patchily distributed on its host plants. We conducted two experiments with (1) groups of juvenile P. persimilis under limited food on interconnected detached leaflets, and (2) groups of adult P. persimilis females under limited food on whole plants. Familiar individuals of both juvenile and adult predator groups were more exploratory and dispersed earlier from a given spider mite patch, occupied more leaves and depleted prey more quickly than individuals of unfamiliar groups. Moreover, familiar juvenile predators had higher survival chances than unfamiliar juveniles. We argue that patch-exploitation and -leaving, and inter-patch dispersion were more favorably coordinated in groups of familiar than unfamiliar predators, alleviating intraspecific competition and improving prey utilization and suppression.

  9. International Survey of Critically Ill Children with Acute Neurological Insults: The PANGEA study

    PubMed Central

    Fink, Ericka L.; Kochanek, Patrick M.; Tasker, Robert C.; Beca, John; Bell, Michael J.; Clark, Robert S. B.; Hutchison, Jamie; Vavilala, Monica S.; Fabio, Anthony; Angus, Derek C.; Watson, R. Scott

    2016-01-01

    Objective The international scope of critical neurological insults in children is unknown. Our objective was to assess the prevalence and outcomes of children admitted to pediatric intensive care units (PICUs) with acute neurological insults. Design Prospective study. Setting Multicenter (n=107 PICUs) and multinational (23 countries, 79% in North America and Europe). Patients Children aged 7d–17y admitted to the ICU with new traumatic brain injury, stroke, cardiac arrest, central nervous system infection or inflammation, status epilepticus, spinal cord injury, hydrocephalus, or brain mass. Interventions None. Measurements and main results We evaluated the prevalence and outcomes of children with pre-determined acute neurological insults. Child and center characteristics were recorded. Unfavorable outcome was defined as change in pre-post insult Pediatric Cerebral Performance Category (PCPC) score ≥ 2 or death at hospital discharge or 3 months, whichever came first. Screening data yielded overall prevalence of 16.2%. Of 924 children with acute neurological insults, cardiac arrest (23%) and traumatic brain injury (19%) were the most common. All-cause mortality at hospital discharge was 12%. Cardiac arrest subjects had highest mortality (24%), and TBI subjects had the most unfavorable outcomes (49%). The most common neurological insult was infection/inflammation in South America, Asia, and the single African site but cardiac arrest in the remaining regions. Conclusions Neurological insults are a significant pediatric international health issue. They are frequent and contribute substantial morbidity and mortality. These data suggest a need for an increased focus on acute critical neurological diseases in infants and children including additional research, enhanced availability of clinical resources, and the development of new therapies. PMID:28207570

  10. Pharmacokinetic Evaluation of Two Nicotine Patches in Smokers.

    PubMed

    Rasmussen, Scott; Horkan, Kathleen Halabuk; Kotler, Mitchell

    2018-02-02

    Smoking continues to be a major preventable cause of early mortality worldwide, and nicotine replacement therapy has been demonstrated to increase rates of abstinence among smokers attempting to quit. Nicotine transdermal systems (also known as nicotine patches) attach to the skin via an adhesive layer composed of a mixture of different-molecular-weight polyisobutylenes (PIBs) in a specific ratio. This randomized, single-dose, 2-treatment, crossover pharmacokinetic (PK) trial assessed the bioequivalence of nicotine patches including a replacement PIB adhesive (test) compared with the PIB adhesive historically used on marketed patches (reference). The test and reference patches were bioequivalent, as determined by the PK parameters of C max and AUC 0-t . In addition, the parameters T max and t 1/2 did not significantly differ between the 2 patches, supporting the bioequivalence finding from the primary analysis. The tolerability profiles of the patches containing the replacement and previously used PIB adhesives were similar; application-site adverse events did not significantly differ between test and reference patches. Overall, these data establish the bioequivalence of the nicotine patch with the replacement PIB adhesive formulation and the previously utilized PIB adhesive formulation. © 2018 The Authors. Clinical Pharmacology in Drug Development published by Wiley Periodicals, Inc. on behalf of The American College of Clinical Pharmacology.

  11. The impact of repeat-testing of common chemistry analytes at critical concentrations.

    PubMed

    Onyenekwu, Chinelo P; Hudson, Careen L; Zemlin, Annalise E; Erasmus, Rajiv T

    2014-12-01

    Early notification of critical values by the clinical laboratory to the treating physician is a requirement for accreditation and is essential for effective patient management. Many laboratories automatically repeat a critical value before reporting it to prevent possible misdiagnosis. Given today's advanced instrumentation and quality assurance practices, we questioned the validity of this approach. We performed an audit of repeat-testing in our laboratory to assess for significant differences between initial and repeated test results, estimate the delay caused by repeat-testing and to quantify the cost of repeating these assays. A retrospective audit of repeat-tests for sodium, potassium, calcium and magnesium in the first quarter of 2013 at Tygerberg Academic Laboratory was conducted. Data on the initial and repeat-test values and the time that they were performed was extracted from our laboratory information system. The Clinical Laboratory Improvement Amendment criteria for allowable error were employed to assess for significant difference between results. A total of 2308 repeated tests were studied. There was no significant difference in 2291 (99.3%) of the samples. The average delay ranged from 35 min for magnesium to 42 min for sodium and calcium. At least 2.9% of laboratory running costs for the analytes was spent on repeating them. The practice of repeating a critical test result appears unnecessary as it yields similar results, delays notification to the treating clinician and increases laboratory running costs.

  12. Testing metapopulation concepts: effects of patch characteristics and neighborhood occupancy on the dynamics of an endangered lagomorph

    USGS Publications Warehouse

    Eaton, Mitchell J.; Hughes, Phillip T.; Hines, James E.; Nichols, James D.

    2014-01-01

    Metapopulation ecology is a field that is richer in theory than in empirical results. Many existing empirical studies use an incidence function approach based on spatial patterns and key assumptions about extinction and colonization rates. Here we recast these assumptions as hypotheses to be tested using 18 years of historic detection survey data combined with four years of data from a new monitoring program for the Lower Keys marsh rabbit. We developed a new model to estimate probabilities of local extinction and colonization in the presence of nondetection, while accounting for estimated occupancy levels of neighboring patches. We used model selection to identify important drivers of population turnover and estimate the effective neighborhood size for this system. Several key relationships related to patch size and isolation that are often assumed in metapopulation models were supported: patch size was negatively related to the probability of extinction and positively related to colonization, and estimated occupancy of neighboring patches was positively related to colonization and negatively related to extinction probabilities. This latter relationship suggested the existence of rescue effects. In our study system, we inferred that coastal patches experienced higher probabilities of extinction and colonization than interior patches. Interior patches exhibited higher occupancy probabilities and may serve as refugia, permitting colonization of coastal patches following disturbances such as hurricanes and storm surges. Our modeling approach should be useful for incorporating neighbor occupancy into future metapopulation analyses and in dealing with other historic occupancy surveys that may not include the recommended levels of sampling replication.

  13. Patch test reactions to mite antigens: a GERDA multicentre study. Groupe d'Etudes et de Recherches en Dermato-Allergie.

    PubMed

    Castelain, M; Birnbaum, J; Castelain, P Y; Ducombs, G; Grosshans, E; Jelen, G; Lacroix, M; Meynadier, J; Mougeolle, J M; Lachapelle, J M

    1993-11-01

    We performed patch tests with Dermatophagoides pteronyssinus (Dp) antigens from 2 different sources in 355 non-randomly selected patients with atopic dermatitis (AD) and 398 subjects of a control group. The study demonstrated that contact sensitization to mites occurred in an appreciable % of AD cases (20.8%), using commonly available assay products. The differences recorded between the 2 materials tested were related to the concentration of P1 antigen. Non-atopic patients rarely showed positive reactions to Dp (0.75%), when strict criteria for readings were applied and if 2 readings were performed. Patients with positive patch tests did not necessarily show positive immediate skin tests. It would be useful to carry out tests systematically in atopic patients, even if it is not yet known what modern treatment would be best for the patient. Laboratories still do not provide standardized house dust mite preparations--measuring and codifying their biological activity--for use in patch tests. It is to be hoped that the extension of this type of test will lead to the production of better test materials, in syringes with homogeneous dispersion and concentration.

  14. Effects of interpretation training on hostile attribution bias and reactivity to interpersonal insult.

    PubMed

    Hawkins, Kirsten A; Cougle, Jesse R

    2013-09-01

    Research suggests that individuals high in anger have a bias for attributing hostile intentions to ambiguous situations. The current study tested whether this interpretation bias can be altered to influence anger reactivity to an interpersonal insult using a single-session cognitive bias modification program. One hundred thirty-five undergraduate students were randomized to receive positive training, negative training, or a control condition. Anger reactivity to insult was then assessed. Positive training led to significantly greater increases in positive interpretation bias relative to the negative group, though these increases were only marginally greater than the control group. Negative training led to increased negative interpretation bias relative to other groups. During the insult, participants in the positive condition reported less anger than those in the control condition. Observers rated participants in the positive condition as less irritated than those in the negative condition and more amused than the other two conditions. Though mediation of effects via bias modification was not demonstrated, among the positive condition posttraining interpretation bias was correlated with self-reported anger, suggesting that positive training reduced anger reactivity by influencing interpretation biases. Findings suggest that positive interpretation training may be a promising treatment for reducing anger. However, the current study was conducted with a non-treatment-seeking student sample; further research with a treatment-seeking sample with problematic anger is necessary. Copyright © 2013. Published by Elsevier Ltd.

  15. Patch testing in Israeli children with suspected allergic contact dermatitis: A retrospective study and literature review.

    PubMed

    Zafrir, Yaron; Trattner, Akiva; Hodak, Emmillia; Eldar, Oren; Lapidoth, Moshe; Ben Amitai, Dan

    2018-01-01

    Childhood allergic contact dermatitis is recognized as a significant clinical problem. The objective was to evaluate the rate of positive patch tests in Israeli children with clinically suspected allergic contact dermatitis, identify possible sex and age differences, compare results with those in Israeli adults, and review pediatric studies in the literature. The study sample included 343 children and adolescents (197 female, 146 male; 1-18 years of age, mean age 11.8 years) with clinically suspected allergic contact dermatitis who underwent patch testing with a standard pediatric series of 23 allergens at a tertiary medical center from 1999 to 2012. Data on clinical characteristics and test results were collected retrospectively from the medical files. Ninety-eight subjects (28.6%) (75 girls [38.1%], 23 boys [15.8%]) had at least one positive reaction. The most frequent reactions were to nickel sulfate, followed by potassium dichromate and cobalt chloride. Nickel sulfate sensitivity was more common in girls, especially those younger than 3 years and older than 12 years. The prevalence of contact sensitization was similar in subjects with and without atopic dermatitis (50% and 51%, respectively). Nickel is the most common allergen in Israeli children, especially girls. Patch testing should be performed in children with clinically suspected allergic contact dermatitis regardless of atopic background. © 2017 Wiley Periodicals, Inc.

  16. Testing Multiple Outcomes in Repeated Measures Designs

    ERIC Educational Resources Information Center

    Lix, Lisa M.; Sajobi, Tolulope

    2010-01-01

    This study investigates procedures for controlling the familywise error rate (FWR) when testing hypotheses about multiple, correlated outcome variables in repeated measures (RM) designs. A content analysis of RM research articles published in 4 psychology journals revealed that 3 quarters of studies tested hypotheses about 2 or more outcome…

  17. The Complementary Use of Audience Response Systems and Online Tests to Implement Repeat Testing: A Case Study

    ERIC Educational Resources Information Center

    Stratling, Rebecca

    2017-01-01

    Although learning theories suggest that repeat testing can be highly beneficial for students' retention and understanding of material, there is, so far, little guidance on how to implement repeat testing in higher education. This paper introduces one method for implementing a three-stage model of repeat testing via computer-aided formative…

  18. Additive value of patch testing custom epoxy materials from the workplace at the occupational disease specialty clinic in Toronto.

    PubMed

    Houle, Marie-Claude; Holness, D Linn; Dekoven, Joel; Skotnicki, Sandy

    2012-01-01

    Allergic contact dermatitis (ACD) to epoxy resins is one of the major causes of occupationally induced ACD. Testing of custom epoxy materials from the workplace is often performed to diagnose ACD. The objective of this study was to investigate the additive value of patch testing custom-made epoxy materials. We retrospectively analyzed outcomes of 24 patients who were tested to custom epoxy resin materials between January 2002 and July 2011. For 11 patients (46%), the testing of their materials from work had no additional value (negative results). For 13 patients (54%), there was an additional value of testing custom allergens. Of those, 7 patients (54%) had positive reactions to custom epoxy materials that reinforced the test results found with the commercially available allergens, and 6 (46%) patients had positive reactions only to custom epoxy materials. Therefore, for 6 patients (25%), there was a definite additive value of testing custom epoxy materials because the allergy was discovered with custom testing and not with the commercially available allergens. Because of the high percentage (54%) of patients with additive value of patch testing custom epoxy materials, we think that the inclusion of actual workplace epoxy materials should be strongly considered when patch testing patients with occupational epoxy exposure.

  19. Diagnostic patch testing following tuberculosis-associated cutaneous adverse drug reactions induces systemic reactions in HIV-infected persons.

    PubMed

    Lehloenya, R J; Todd, G; Wallace, J; Ngwanya, M R; Muloiwa, R; Dheda, K

    2016-07-01

    The incidence of cutaneous adverse drug reactions (CADRs) to first-line antituberculosis drugs (FLTDs) is higher in HIV-tuberculosis coinfection. However, the utility of patch testing to identify the offending drug in this patient subgroup has been poorly studied. To identify drugs causing adverse drug reactions in patients with HIV-tuberculosis coinfection. Fourteen consecutive patients underwent diagnostic work-up (patch testing followed by a skin prick test and an oral rechallenge) to pinpoint the offending drug after developing FLTD-associated CADR, which included drug rash with eosinophilia and systemic symptoms (n = 12), Stevens-Johnson syndrome (SJS, n = 1) and toxic epidermal necrolysis/SJS overlap (n = 1). A positive reaction to any of the three diagnostic modalities eliminated that drug from the regimen. Once patients were clinically stable postreaction, sequential and additive rechallenge with FLTDs was initiated. Eleven of the 14 participants with FLTD-associated CADR were HIV infected (median CD4 count 149 cells mm(-3) ). In this subgroup, patch testing resulted in generalized systemic reactions in 10 of 11 patients (91%). These included rash in 10 of 13 reactions (77%), eosinophilia in eight (62%), transaminitis in seven (54%) and fever in five (38%). Isoniazid caused six of 13 (46%) generalized systemic reactions, rifampicin four (31%), ethambutol two (15%) and pyrazinamide one reaction. Using the Common Terminology Criteria for Adverse Events, five of 13 reactions were mild, six were moderate and two were severe. There were no life-threatening or fatal reactions. In HIV-infected persons with tuberculosis-associated CADR, although patch-testing reactions to FLTD are common and tend to be associated with systemic features, they are not life threatening or fatal. These data inform clinical practice in HIV-endemic settings. © 2016 British Association of Dermatologists.

  20. Recommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series.

    PubMed

    Bruze, Magnus; Andersen, Klaus Ejner; Goossens, An

    2008-03-01

    The currently used fragrance mix in the European baseline patch test series (baseline series) fails to detect a substantial number of clinically relevant fragrance allergies. To investigate whether it is justified to include hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) and fragrance mix 2 containing hydroxyisohexyl 3-cyclohexene carboxaldehyde, citral, farnesol, coumarin, citronellol, and alpha-hexyl cinnamal in the European baseline patch test series. Survey of the literature on reported frequencies of contact allergy and allergic contact dermatitis from fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) as well as reported results of experimental provocation test. Fragrance mix 2 has been demonstrated to be a useful additional marker of fragrance allergy with contact allergy rates up to 5% when included in various national baseline patch test series. Of the fragrance substances present in fragrance mix 2, hydroxyisohexyl 3-cyclohexene carboxaldehyde is the most common sensitizer. Contact allergy rates between 1.5% and 3% have been reported for hydroxyisohexyl 3-cyclohexene carboxaldehyde in petrolatum (pet.) at 5% from various European centres when tested in consecutive dermatitis patients. From 2008, pet. preparations of fragrance mix 2 at 14% w/w (5.6 mg/cm(2)) and hydroxyisohexyl 3-cyclohexene carboxaldehyde at 5% w/w (2.0 mg/cm(2)) are recommended for inclusion in the baseline series. With the Finn Chamber technique, a dose of 20 mg pet. preparation is recommended. Whenever there is a positive reaction to fragrance mix 2, additional patch testing with the 6 ingredients, 5 if there are simultaneous positive reactions to hydroxyisohexyl 3-cyclohexene carboxaldehyde and fragrance mix 2, is recommended.

  1. Methylisothiazolinone contact allergy in Croatia: Epidemiology and course of disease following patch testing.

    PubMed

    Ljubojević Hadžavdić, Suzana; Uter, Wolfgang; Ilijanić Samošćanec, Maja; Johansen, Jeanne D

    2018-05-30

    Methylisothiazolinone (MI) caused an epidemic of contact allergy in Europe, as shown by data from many countries, but no studies from Croatia exist. Also, data are lacking on the severity of allergic contact dermatitis (ACD) caused by MI, and its impact on quality of life and prognosis. To determine the frequency of MI contact allergy among Croatian dermatitis patients, identify causative exposures, assess the impact of disease, and study the prognosis. Data were collected for consecutive dermatitis patients with MI contact allergy patch tested in Croatia between November 2, 2015 and November 3, 2016. MI contact allergy was diagnosed in 13.2% of 798 tested patients. The most frequent dermatitis locations were the hands (76%) and face (61%). In 89.3% of patients, MI contact allergy was found to be of current relevance. Considerable severity and impact on daily life of disease was found at the first consultation, but this significantly decreased until follow-up 3 months later. Patch testing is the standard method for the diagnosis of ACD, and it has been shown to have an important beneficial effect on prognosis. The severity of MI ACD and the impact on daily life emphasize the need for prevention. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. The effect of repeated testing vs repeated practice on skills learning in undergraduate dental education.

    PubMed

    Sennhenn-Kirchner, S; Goerlich, Y; Kirchner, B; Notbohm, M; Schiekirka, S; Simmenroth, A; Raupach, T

    2018-02-01

    Recent studies in undergraduate medical education have demonstrated the advantage of repeated testing over repeated practice with regard to knowledge and skills retention. The aim of this study was to investigate whether this "testing effect" also applies to skills retention in undergraduate dental education. In this prospective, randomised controlled trial, fourth-year dental students at Göttingen University Medical Centre participated in a training session on surgical suturing in winter term 2014/2015. Following this, they were either assigned to two sessions of additional skills training (group A) or two sessions of skills assessment with feedback (group B). These sessions were spaced over a period of 4 weeks. Skills retention was assessed in a summative objective structured clinical examination (OSCE) at the end of term, that is 6 months after the initial teaching session. A total of 32 students completed the study. With regard to suturing, OSCE performance was significantly better in group B than group A (81.9±13.1% vs 63.0±15.4%; P=0.001; Cohen's d=1.33). There was no significant OSCE performance difference in the two groups with regard to other learning objectives that were addressed in the end-of-term examination. Thus, the group difference was specific to suturing skills. This is the first study to demonstrate that in dental education, repeated testing produces more favourable skills retention than repeated practice. Test-enhanced learning might be a viable concept for skills retention in undergraduate dentistry education. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Is Retrieval Mediated after Repeated Testing?

    ERIC Educational Resources Information Center

    Kole, James A.; Healy, Alice F.

    2013-01-01

    In 2 main experiments, the mediated priming effect was used to determine whether retrieval continues to be mediated after repeated testing. In each experiment, participants used the keyword method to learn French vocabulary, then completed a modified lexical decision task in which they first translated a French word, and then made a lexical…

  4. Impact of Inclusion or Exclusion of Repeaters on Test Equating

    ERIC Educational Resources Information Center

    Puhan, Gautam

    2011-01-01

    This study examined the effect of including or excluding repeaters on the equating process and results. New forms of two tests were equated to their respective old forms using either all examinees or only the first timer examinees in the new form sample. Results showed that for both tests used in this study, including or excluding repeaters in the…

  5. Multicenter Patch Testing With Methylisothiazolinone and Methylchloroisothiazolinone/Methylisothiazolinone Within the International Contact Dermatitis Research Group.

    PubMed

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E; Elsner, Peter; Goh, Chee-Leok; Goossens, An; Jerajani, Hemangi; Matsunaga, Kayoko; McFadden, John; Bruze, Magnus

    The preservatives methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and MI are well-known contact sensitizers. Recently, an increase in the contact allergy frequency for MI 0.2% aqueous (aq) has been seen in many European countries paralleled with an increase in MCI/MI allergy. Many of the MI-allergic patients do not react to MCI/MI 0.01% or 0.02% because the concentration of MI in these preparations is too low (25 and 50 ppm, respectively) to elicit a positive patch test reaction. The aims of this study were to investigate the prevalence of contact allergy to MI in the participating clinics representing various countries all over the world, to assess how many additional individuals with contact allergy are found by testing MI 0.2% aq in parallel with MCI/MI 0.02%, and to assess the clinical relevance of MI and MCI/MI allergies. In 9 dermatology clinics representing 9 countries, 3865 consecutive patients with dermatitis were patch tested with MI 0.2% aq and in parallel with MCI/MI 0.02% aq, provisionally included into the baseline series. An assessment of clinical relevance in those allergic to MI was also made. Contact allergy to MI was found in 284 patients (7.3%). The frequency of contact allergy varied from 0.8% to 10.9% in different centers. Simultaneous reactivity to 200 ppm of MCI/MI was found in 67.3% of the MI-positive patients. Contact allergy to MI alone without any simultaneous contact allergy to 200 ppm of MCI/MI was diagnosed in 93 patients (32.7%; 2.4% of all tested patients). The contact allergy to MI and/or MCI/MI could explain or contribute to dermatitis in more than 60% of the MI-allergic patients. Methylisothiazolinone of 2000 ppm needs to be patch tested on its own to not miss contact allergy.

  6. Membrane depolarization and aberrant lipid distributions in the neonatal rat brain following hypoxic-ischaemic insult.

    PubMed

    Luptakova, Dominika; Baciak, Ladislav; Pluhacek, Tomas; Skriba, Anton; Sediva, Blanka; Havlicek, Vladimir; Juranek, Ivo

    2018-05-03

    Neonatal hypoxic-ischaemic (HI) encephalopathy is among the most serious complications in neonatology. In the present study, we studied the immediate (0 hour), subacute (36 hours) and late (144 hours) responses of the neonatal brain to experimental HI insult in laboratory rats. At the striatal level, the mass spectrometry imaging revealed an aberrant plasma membrane distribution of Na + /K + ions in the oedema-affected areas. The failure of the Na + /K + gradients was also apparent in the magnetic resonance imaging measurements, demonstrating intracellular water accumulation during the acute phase of the HI insult. During the subacute phase, compared with the control brains, an incipient accumulation of an array of N-acylphosphatidylethanolamine (NAPE) molecules was detected in the HI-affected brains, and both the cytotoxic and vasogenic types of oedema were detected. In the severely affected brain areas, abnormal distributions of the monosialogangliosides GM2 and GM3 were observed in two-thirds of the animals exposed to the insult. During the late stage, a partial restoration of the brain tissue was observed in most rats in both the in vivo and ex vivo studies. These specific molecular changes may be further utilized in neonatology practice in proposing and testing novel therapeutic strategies for the treatment of neonatal HI encephalopathy.

  7. Strategic Public Health Concerns Resulting From Cognitive Insult on the Modern Battlefield and Cognitive Readiness

    DTIC Science & Technology

    2012-04-01

    Faculty In Partial Fulfillment of the Graduation Requirements Advisor: John Kelliher, PhD and James Wright, PhD Maxwell Air Force Base ...physical end of the insult spectrum is TBI. This insult is generally caused by some type of trauma in the CNS and is seen frequently in military...insult to the integrity of the environment of the CNS leaves the soldier susceptible to infection if the wound is not immediately cared for in a

  8. Patch test results in children and adolescents. Study from the Santa Casa de Belo Horizonte Dermatology Clinic, Brazil, from 2003 to 2010*

    PubMed Central

    Rodrigues, Dulcilea Ferraz; Goulart, Eugênio Marcos Andrade

    2015-01-01

    BACKGROUND Patch testing is an efficient method to identify the allergen responsible for allergic contact dermatitis. OBJECTIVE To evaluate the results of patch tests in children and adolescents comparing these two age groups' results. METHODS Cross-sectional study to assess patch test results of 125 children and adolescents aged 1-19 years, with suspected allergic contact dermatitis, in a dermatology clinic in Brazil. Two Brazilian standardized series were used. RESULTS Seventy four (59.2%) patients had "at least one positive reaction" to the patch test. Among these positive tests, 77.0% were deemed relevant. The most frequent allergens were nickel (36.8%), thimerosal (18.4%), tosylamide formaldehyde resin (6.8%), neomycin (6.4%), cobalt (4.0%) and fragrance mix I (4.0%). The most frequent positive tests came from adolescents (p=0.0014) and females (p=0.0002). There was no relevant statistical difference concerning contact sensitizations among patients with or without atopic history. However, there were significant differences regarding sensitization to nickel (p=0.029) and thimerosal (p=0.042) between the two age groups under study, while adolescents were the most affected. CONCLUSION Nickel and fragrances were the only positive (and relevant) allergens in children. Nickel and tosylamide formaldehyde resin were the most frequent and relevant allergens among adolescents. PMID:26560213

  9. Shoe contact dermatitis from dimethyl fumarate: clinical manifestations, patch test results, chemical analysis, and source of exposure.

    PubMed

    Giménez-Arnau, Ana; Silvestre, Juan Francisco; Mercader, Pedro; De la Cuadra, Jesus; Ballester, Isabel; Gallardo, Fernando; Pujol, Ramón M; Zimerson, Erik; Bruze, Magnus

    2009-11-01

    The methyl ester form of fumaric acid named dimethyl fumarate (DMF) is an effective mould-growth inhibitor. Its irritating and sensitizing properties were demonstrated in animal models. Recently, DMF has been identified as responsible for furniture contact dermatitis in Europe. To describe the clinical manifestations, patch test results, shoe chemical analysis, and source of exposure to DMF-induced shoe contact dermatitis. Patients with suspected shoe contact dermatitis were studied in compliance with the Declaration of Helsinki. Patch test results obtained with their own shoe and the European baseline series, acrylates and fumaric acid esters (FAE), were recorded according to international guidelines. The content of DMF in shoes was analysed with gas chromatography and mass spectrometry. Acute, immediate irritant contact dermatitis and non-immunological contact urticaria were observed in eight adults and two children, respectively. All the adult patients studied developed a delayed sensitization demonstrated by a positive patch testing to DMF < or = 0.1% in pet. Cross-reactivity with other FAEs and acrylates was observed. At least 12 different shoe brands were investigated. The chemical analysis from the available shoes showed the presence of DMF. DMF in shoes was responsible for severe contact dermatitis. Global preventive measures for avoiding contact with DMF are necessary.

  10. Recommendation to increase the test concentration of methylchloroisothiazolinone/methylisothiazolinone in the European baseline patch test series - on behalf of the European Society of Contact Dermatitis and the European Environmental and Contact Dermatitis Research Group.

    PubMed

    Bruze, Magnus; Goossens, An; Isaksson, Marléne

    2014-07-01

    Methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) in aqua is present in the European baseline patch test series at 100 ppm, whereas 200 ppm has been used in Sweden since 1986, in Spain in the late 1980s, and, in recent years, also in the United Kingdom and Ireland. With regard to MCI/MI, to investigate the data on contact allergy rates in dermatitis patients, the frequencies of allergic contact dermatitis in the same group, and adverse reactions, particularly patch test sensitization in tested dermatitis patients, and to find the optimal patch test concentration as dose in mg/cm(2) . We performed a survey of the literature found via the National Library of Medicine (PubMed, http://www.ncbi.nlm.nih.gov/pubmed, last accessed 20 February 2014). MCI/MI at 200 ppm aq. diagnosis substantially more contact allergy and allergic contact dermatitis, without any registered increase in patch test sensitization, than the presently used concentration of 100 ppm. MCI/MI at 200 ppm aq. is recommended to be included in the European baseline patch test series. To avoid patch test sensitization, a dose of 0.006 mg/cm(2) must not be exceeded, which means a volume of 15 µl for Finn Chambers(®) (Ø 8 mm). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Winter season, frequent hand washing, and irritant patch test reactions to detergents are associated with hand dermatitis in healthcare workers

    PubMed Central

    Callahan, Adrienne; Baron, Elma; Fekedulegn, Desta; Kashon, Michael; Yucesoy, Berran; Johnson, Victor J.; Santo Domingo, Diana; Kirkland, Brent; Luster, Michael I.; Nedorost, Susan

    2013-01-01

    Background Irritant hand dermatitis (IHD) is common in healthcare workers. Objective We studied endogenous irritant contact dermatitis threshold by patch testing, and exogenous factors such as season and hand washing for their association with IHD in healthcare workers. Methods Irritant patch testing with sodium lauryl sulfate (SLS), sodium hydroxide (NaOH) and benzalkonium chloride (BAK) at varying concentrations was measured in 113 healthcare workers. Examination for hand dermatitis occurred at one month intervals for a period of six months in the Midwestern US. Results Positive patch testing to low concentration SLS was associated with IHD (p=0.0310) after adjusting for age, gender, ethnicity, season, history of childhood flexural dermatitis, mean indoor relative humidity, glove and hand sanitizer usage). Subjects with a positive patch test to SLS were 78% more likely to have occurrence of IHD (IRR=1.78, 95% CI: 0.92, 3.45). Hand washing frequency (≥ 10 times a day; IRR=1.55, 95% CI: 1.01, 2.39) and cold season (IRR=2.76, 95% CI: 1.35, 5.65) were associated with IHD. No association was found between history of childhood flexural dermatitis and IHD in this population. Conclusions Both genetic and environmental factors are important in the etiology of IHD and should be considered in designing strategies to protect, educate and treat susceptible individuals. PMID:23857011

  12. Effect of sexual coercion proclivity, insult and fantasy on emotional reactivity and appeal of sexual aggression.

    PubMed

    Thomas, Lindsey A; Gorzalka, Boris B

    2012-08-01

    Fifty-nine heterosexual university males were assessed for Sexual Coercion Proclivity (SCP) and randomly assigned to one of three conditions: Insult/nonsexually coercive fantasy material; no insult/sexually coercive fantasy material; or, insult/sexually coercive fantasy material. Although not differing in terms of anger or anxiety, the high SCP became more frustrated than the low group, particularly when exposed to both insult and sexually coercive (SC) fantasy material. Changes in negative affect predicted anticipated likelihood of engaging in SC among the low SCP group and anticipated enjoyment of SC in the high SCP group. Acculturation accounted for differences observed between Caucasian and Chinese men.

  13. Fragrance allergy could be missed without patch testing with 26 individual fragrance allergens.

    PubMed

    Vejanurug, Patnapa; Tresukosol, Poohglin; Sajjachareonpong, Praneet; Puangpet, Pailin

    2016-04-01

    In 2003, the EU Cosmetics Directive stated that 26 fragrance substances must be listed on the cosmetic product ingredient labels. Not all of these 26 fragrance substances are detected by the usual screening markers comprising fragrance mix I, fragrance mix II, and Myroxylon pereirae. To evaluate the usefulness of testing with the 26 individual fragrance substances in addition to the standard fragrance screening markers. Three hundred and twelve consecutive patients were patch tested with our baseline series and the 26 specific fragrance substances required to be declared on cosmetic product ingredient labels in accordance with the EU Cosmetics Directive. Positive reactions to at least either one of the 26 individual fragrance substances or the usual fragrance screening markers were seen in 84 of 312 patients (26.9%). Fifteen of these 84 patients (17.8%) reacted negatively to the fragrance screening markers. The most common individual fragrance allergens were cinnamyl alcohol (11.2%), cinnamal (9%), and hydroxycitronellal (3.8%). Sixty-two of 312 patients (19.8%) had at least one positive reaction to the fragrance screening markers. Additional patch testing with the 26 individual fragrance allergens, or with the commonest fragrance allergens identified within these 26, should be performed to optimize the detection of fragrance allergy. Cinnamyl alcohol and cinnamal are important fragrance allergens in Thailand. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Repeat neurobehavioral study of borderline personality disorder.

    PubMed Central

    van Reekum, R; Links, P S; Finlayson, M A; Boyle, M; Boiago, I; Ostrander, L A; Moustacalis, E

    1996-01-01

    Previous research has tentatively identified a large subgroup of patients with borderline personality disorder (BPD) with histories of developmental or acquired brain insults. Similarly, these studies have demonstrated a possible biological correlation between the severity of BPD and the number of previous brain insults. The possibility of frontal system cognitive dysfunction in BPD has been raised. This single-blind, case-control study of BPD showed that 13 of 24 subjects with BPD had suffered a brain insult. Correlations between neurodevelopmental/acquired brain injury score and the diagnostic interview for borderline (DIB) score (r = 0.47), and between frontal system cognitive functioning and DIB score (r = -0.37) were seen. Neurocognitive testing and comparison with a cohort of subjects with traumatic brain injury (TBI) showed a pattern of similar cognitive functioning between the 2 groups, with the only differences on individual tests being in the direction of worse functioning in the group with BPD on 2 tasks. These results support the hypotheses described above. The main limitation reflects the low numbers of subjects. PMID:8580113

  15. Unusual fentanyl patch administration.

    PubMed

    Thomas, Sandra; Winecker, Ruth; Pestaner, Joseph P

    2008-06-01

    Fentanyl is an extremely potent narcotic analgesic that is becoming more popular as a drug of abuse. Because of the unique way in which the drug is packaged and delivered, the potential for unusual methods of abuse exists. We report the first case of true fentanyl patch ingestion in the medical literature. Initially, though unusual, cases of fentanyl ingestion were thought to have been reported, but further investigation of the literature revealed that in other case reports the patches had been held in the mouth and chewed. Because no reports of swallowing the patch had been published, suicide was initially a strong consideration in this case; however, further investigation showed that the decedent and his brother enjoyed swallowing the patches for quick "highs." Cases such as these serve to remind medical examiners and law enforcement officials of the value of performing thorough death investigations by performing complete autopsies with toxicological testing and correlating with investigation information to form an opinion with regard to the cause and manner of death.

  16. [Drug patch tests in the investigation of a fixed drug eruption subsequent to 2 courses of cyclophosphamide in combination with mesna].

    PubMed

    Delaigue, S; Boye, T; Pasquine, C; Guetta, K; Alla, P; Ponte-Astoul, J; Morand, J-J

    2015-01-01

    When fixed drug eruption occurs following use of cyclophosphamide and mesna, it is difficult to establish which drug is responsible. We report a new case of patch tests that resulted in withdrawal of mesna and enabled continued treatment with cyclophophamide. A 57-year-old female patient with multiple sclerosis presented increasingly severe cutaneous lesions after successive courses of cyclophosphamide. Twenty-four hours after her latest treatment, she presented at the ER with a worse eruption than those to date and including facial lesions. The clinical diagnosis was a fixed drug eruption, and patch tests for mesna one month later were positive. Fixed drug eruption always occurs after recurrent treatment and the investigation must be precise. Patch tests may be used to determine which drug could be responsible. The most conclusive test comprises withdrawal of the incriminated drug with no further signs of drug eruption on resumption of the other medication. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Repeat Chlamydia trachomatis testing among heterosexual STI outpatient clinic visitors in the Netherlands: a longitudinal study.

    PubMed

    Visser, Maartje; van Aar, Fleur; Koedijk, Femke D H; Kampman, Carolina J G; Heijne, Janneke C M

    2017-12-20

    Chlamydia infections are common in both men and women, are often asymptomatic and can cause serious complications. Repeat testing in high-risk groups is therefore indicated. In the Netherlands, guidelines on repeat chlamydia testing differ between testing facilities, and knowledge on repeat testing behaviour is limited. Here, we analyse the current repeat testing behaviour of heterosexual STI clinic visitors, and aim to identify groups for which repeat testing advice could be advantageous. Longitudinal surveillance data from all Dutch STI outpatient clinics were used, which included all STI clinic consultations carried out among heterosexual men and women between June 2014 and December 2015. Repeat testing was defined as returning to the same STI clinic between 35 days and 12 months after initial consultation. We calculated chlamydia positivity at repeat test stratified by initial test result and time between consultations. Logistic regression analyses were used to identify predictors of repeat testing, and predictors of having a chlamydia positive repeat test. In total, 140,486 consultations in 75,487 women and 46,286 men were available for analyses. Overall, 15.4% of women and 11.1% of men returned to the STI clinic within the study period. Highest chlamydia positivity at repeat test was seen 3-5 months after initial positive test. Among both women and men, repeat testing was associated with non-Western ethnicity, having had more than two sex partners in the past 6 months, reporting STI symptoms, having a history of STI, and having a chlamydia positive initial test. Among repeat testers, chlamydia positive repeat test was most strongly associated with younger age, followed by a chlamydia positive initial test. Repeat testing most often resulted in a positive test result among young heterosexuals (<25) and heterosexuals of any age with a chlamydia infection at the initial consultation. Further efforts are needed to determine optimal repeat testing strategies.

  18. Evaluation of accuracy, reliability, and repeatability of five dental pulp tests.

    PubMed

    Chen, Eugene; Abbott, Paul V

    2011-12-01

    The aim of this study was to compare the clinical accuracy, reliability, and repeatability of laser Doppler flowmetry (LDF), an electric pulp test (EPT), and various thermal pulp sensibility tests. Pulp tests were done on 121 teeth in 20 subjects by using LDF, EPT, and thermal pulp testing (CO(2), Endo Frost [EF], Ice) during 2 or 3 test sessions with at least 1-week intervals. The order of testing was reversed on the second visit. A laser Doppler flowmeter was used to measure mean pulp blood flow (Flux) calibrated against a brownian motion medium and zeroed against a static reflector. The laser source was 780 nm, with 0.5-mm fiber separation in the probe, 3.1 kHz as the primary bandwidth for filter set to 0.1-second time output constant. Customized polyvinylsiloxane splints were fabricated for each participant, and a minimum of 90-second recording time was used for each tooth. Raw data were analyzed by using repeated measure analysis of variance, pairwise comparisons, and interclass correlations (ICC). The accuracy of EPT, CO(2), and LDF tests was 97.7%, 97.0%, and 96.3%, respectively, without significant differences (P > .3). Accuracy of EF and Ice was 90.7% and 84.8%, respectively. EPT (P = .015) and CO(2) (P = .022) were significantly more accurate than EF. LDF was more accurate than EF, but this was not statistically significant (P = .063). Ice was significantly less accurate than EPT (P = .004), CO(2) (P = .005), LDF (P = .006), and EF (P = .019). With the exception of Ice (effect of visit: F(2,38) = 5.67, mean squared error = 0.01, P = .007, η(2)(p) = 0.23), all tests were reliable. Ice (ICC = 0.677) and LDF (ICC = 0.654) were the most repeatable of the tests, whereas EPT (ICC = 0.434) and CO(2) (ICC = 0.432) were less repeatable. CO(2), EPT, and LDF were reliable and the most accurate tests, but CO(2) and EPT were less repeatable yet less time-consuming than LDF. EF was reliable but not as accurate as EPT and CO(2) and less repeatable than Ice and LDF

  19. Patch testing to a textile dye mix by the international contact dermatitis research group.

    PubMed

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E; Diepgen, Thomas; Goh, Chee-Leok; Goossens R, An; Jerajani, Hemangi; Maibach, Howard I; Sasseville, Denis; Bruze, Magnus

    2015-01-01

    Disperse dyes are well-known contact sensitizers not included in the majority of commercially available baseline series. To investigate the outcome of patch testing to a textile dye mix (TDM) consisting of 8 disperse dyes. Two thousand four hundred ninety-three consecutive dermatitis patients in 9 dermatology clinics were patch tested with a TDM 6.6%, consisting of Disperse (D) Blue 35, D Yellow 3, D Orange 1 and 3, D Red 1 and 17, all 1.0% each, and D Blue 106 and D Blue 124, each 0.3%. 90 reacted positively to the TDM. About 92.2% of the patients allergic to the TDM were also tested with the 8 separate dyes. Contact allergy to TDM was found in 3.6% (1.3-18.2) Simultaneous reactivity to p-phenylenediamine was found in 61.1% of the TDM-positive patients. Contact allergy to TDM and not to other p-amino-substituted sensitizers was diagnosed in 1.2%. The most frequent dye allergen in the TDM-positive patients was D Orange 3. Over 30% of the TDM allergic patients had been missed if only the international baseline series was tested. Contact allergy to TDM could explain or contribute to dermatitis in over 20% of the patients. Textile dye mix should be considered for inclusion into the international baseline series.

  20. Simultaneous patch testing with fragrance mix I, fragrance mix II and their ingredients in southern Sweden between 2009 and 2015.

    PubMed

    Mowitz, Martin; Svedman, Cecilia; Zimerson, Erik; Isaksson, Marléne; Pontén, Ann; Bruze, Magnus

    2017-11-01

    Fragrance mix I (FM I) and fragrance mix II (FM II) are included in the European baseline series as screening substances for fragrance contact allergy. To investigate the frequency of allergic reactions to FM I, FM II and their ingredients in consecutively patch tested patients. A retrospective analysis of data from 4430 patients patch tested between 2009 and 2015 was performed. Of the patients, 6.5% were FM I-positive and 3.2% were FM II-positive. Forty-five per cent of FM I-positive patients did not have positive reactions to FM I ingredients. Thirty-five per cent of those who were FM II-positive did not have positive reactions to FM II ingredients. Twenty-seven per cent of those with positive reactions to one or more of the FM I ingredients were FM I-negative, and 36% of those who had positive reactions to one or more of the FM II ingredients were FM II-negative. The allergens with the highest pick-up rates were Evernia prunastri (1.8%), cinnamal (1.3%), citral (1.2%), and hydroxyisohexyl 3-cyclohexene carboxaldehyde (1.2%). Significant differences were observed in the proportions of positive reactions to FM I, FM II, eugenol, isoeugenol, and farnesol when results from patch testing with materials from different suppliers were compared. There is a risk of missing fragrance contact allergy when testing with only the fragrance mixes is performed. The use of preparations from different suppliers may affect the patch test results. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Metal Patch Antenna

    NASA Technical Reports Server (NTRS)

    Chamberlain, Neil F. (Inventor); Zawadzki, Mark S. (Inventor); Hodges, Richard E. (Inventor)

    2012-01-01

    Disclosed herein is a patch antenna comprises a planar conductive patch attached to a ground plane by a support member, and a probe connector in electrical communication with the conductive patch arranged to conduct electromagnetic energy to or from the conductive patch, wherein the conductive patch is disposed essentially parallel to the ground plane and is separated from the ground plane by a spacing distance; wherein the support member comprises a plurality of sides disposed about a central axis oriented perpendicular to the conductive patch and the ground plane; wherein the conductive patch is solely supported above the ground plane by the support member; and wherein the support member provides electrical communication between the planer conductive patch and the ground plane.

  2. Patching. Restitching business portfolios in dynamic markets.

    PubMed

    Eisenhardt, K M; Brown, S L

    1999-01-01

    In turbulent markets, businesses and opportunities are constantly falling out of alignment. New technologies and emerging markets create fresh opportunities. Converging markets produce more. And of course, some markets fade. In this landscape of continuous flux, it's more important to build corporate-level strategic processes that enable dynamic repositioning than it is to build any particular defensible position. That's why smart corporate strategists use patching, a process of mapping and remapping business units to create a shifting mix of highly focused, tightly aligned businesses that can respond to changing market opportunities. Patching is not just another name for reorganizing; patchers have a distinctive mindset. Traditional managers see structure as stable; patching managers believe structure is inherently temporary. Traditional managers set corporate strategy first, but patching managers keep the organization focused on the right set of business opportunities and let strategy emerge from individual businesses. Although the focus of patching is flexibility, the process itself follows a pattern. Patching changes are usually small in scale and made frequently. Patching should be done quickly; the emphasis is on getting the patch about right and fixing problems later. Patches should have a test drive before they're formalized but then be tightly scripted after they've been announced. And patching won't work without the right infrastructure: modular business units, fine-grained and complete unit-level metrics, and companywide compensation parity. The authors illustrate how patching works and point out some common stumbling blocks.

  3. Methyltransferases mediate cell memory of a genotoxic insult.

    PubMed

    Rugo, R E; Mutamba, J T; Mohan, K N; Yee, T; Chaillet, J R; Greenberger, J S; Engelward, B P

    2011-02-10

    Characterization of the direct effects of DNA-damaging agents shows how DNA lesions lead to specific mutations. Yet, serum from Hiroshima survivors, Chernobyl liquidators and radiotherapy patients can induce a clastogenic effect on naive cells, showing indirect induction of genomic instability that persists years after exposure. Such indirect effects are not restricted to ionizing radiation, as chemical genotoxins also induce heritable and transmissible genomic instability phenotypes. Although such indirect induction of genomic instability is well described, the underlying mechanism has remained enigmatic. Here, we show that mouse embryonic stem cells exposed to γ-radiation bear the effects of the insult for weeks. Specifically, conditioned media from the progeny of exposed cells can induce DNA damage and homologous recombination in naive cells. Notably, cells exposed to conditioned media also elicit a genome-destabilizing effect on their neighbouring cells, thus demonstrating transmission of genomic instability. Moreover, we show that the underlying basis for the memory of an insult is completely dependent on two of the major DNA cytosine methyltransferases, Dnmt1 and Dnmt3a. Targeted disruption of these genes in exposed cells completely eliminates transmission of genomic instability. Furthermore, transient inactivation of Dnmt1, using a tet-suppressible allele, clears the memory of the insult, thus protecting neighbouring cells from indirect induction of genomic instability. We have thus demonstrated that a single exposure can lead to long-term, genome-destabilizing effects that spread from cell to cell, and we provide a specific molecular mechanism for these persistent bystander effects. Collectively, our results impact the current understanding of risks from toxin exposures and suggest modes of intervention for suppressing genomic instability in people exposed to carcinogenic genotoxins.

  4. Patch test reactions associated with sunscreen products and the importance of testing to an expanded series: retrospective analysis of North American Contact Dermatitis Group data, 2001 to 2010.

    PubMed

    Warshaw, Erin M; Wang, Michael Z; Maibach, Howard I; Belsito, Donald V; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Sasseville, Denis; Zirwas, Matthew J; Fowler, Joseph F; DeKoven, Joel G; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J

    2013-01-01

    Both active and inactive ingredients in sunscreen may cause contact dermatitis. This study aimed to describe allergens associated with a sunscreen source. A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 2001 and 2010 was performed. Of 23,908 patients patch tested, 219 (0.9%) had sunscreen coded as an allergen source. Patients who were male, with occupational dermatitis, or older (older than 40 years) had significantly lower rates of allergic reactions to sunscreens; the most commonly affected areas were the face and exposed sites (P < 0.0001). The top 3 most frequent allergens in sunscreens were benzophenone-3 (70.2% for 10% concentration, 64.4% for 3% concentration), DL-alpha-tocopherol (4.8%), and fragrance mix I (4.0%). Less than 40% of positive patch test reactions were detected by the North American Contact Dermatitis Group screening series of 65 to 70 allergens. A supplemental antigen series is important in detecting allergy to sunscreens.

  5. Immunophenotyping of the cutaneous cellular infiltrate after atopy patch testing in cats with atopic dermatitis.

    PubMed

    Roosje, P J; Thepen, T; Rutten, V P M G; van den Brom, W E; Bruijnzeel-Koomen, C A F M; Willemse, T

    2004-10-01

    Cats with spontaneously occurring atopic dermatitis have clinical and immunocytochemical characteristics compatible with these in humans with atopic dermatitis (AD). The atopy patch test (APT) has proven to be a valuable tool in elucidating the disease process in humans. Additionally, the APT is very specific and bypasses the problem of conflicting results due to differences in chronicity of lesions of AD patients. We adapted the APT for use in cats to explore the suitability of the APT as a tool to study the onset of allergic inflammation in cats with atopic dermatitis. APT were performed in AD cats (n = 6) and healthy cats (n = 10). All cats were patch tested with two allergens in three different dilutions and a diluent control. The allergens for the APT were selected from positive intradermal test and /or prick test results and consisted of: Dermatophagoides farinae, D. pteronyssinus, Tyrophagus putrescentiae, and a grass pollen mixture. APT were read after 10, 24 and 48 h, and punch biopsies for immunohistochemical evaluation were collected at these time points. Macroscopically positive APT reactions were observed in three out of six cats at 24 and/or 48 h with allergen concentrations of 25,000 and 100,000 NU/ml. Reactions were not observed at negative control sites and neither in control animals. A significantly increased number of IL-4+, CD4+, CD3+, MHC class II+ and CD1a+ cells was found in one AD cat with positive APT reactions. Five out of six AD cats had significantly increased IL-4+ T cell numbers at 24 and/or 48 h. Our data indicate that in cats, macroscopically positive patch test reactions can be induced, which have a cellular infiltrate similar to that in lesional skin. We found a high specificity and a macroscopically positive APT reaction in half of the cats, which is similar to what is seen in humans. Hence, the APT in cats might be a useful tool in studying the immunopathogenesis of feline atopic dermatitis.

  6. The frequency of fragrance allergy in a patch-test population over a 17-year period.

    PubMed

    Buckley, D A; Wakelin, S H; Seed, P T; Holloway, D; Rycroft, R J; White, I R; McFadden, J P

    2000-02-01

    Fragrances are widely encountered in our daily environment and are known to be a common cause of allergic contact dermatitis. We have reviewed our patch test data from 1980 to 1996 to establish whether the pattern of fragrance allergy has changed with time. During this period, 25,545 patients (10,450 male, 15,005 female) were patch tested with the European standard series. The mean annual frequency of positive reactions to the fragrance mix was 8.5% in females (range 6.1-10.9) and 6.7% in males (range 5.1-12.9). Females were 1.3 times more likely to be allergic to fragrance (P < 0.001, 95% confidence interval, CI 1.17-1.41). Males with fragrance allergy were older than females by 5.6 years (mean age 48.2 vs. 42.6 years; P < 0.001, 95% CI 3.9-7.3). The incidence of a concomitant positive patch test to balsam of Peru in fragrance-sensitive patients showed wide variation, suggesting that it is not a reliable marker of fragrance allergy. There was a positive correlation between the isomers isoeugenol and eugenol. Oak moss remained the most common overall allergen throughout the study, positive in 38.3% of females and 35.6% of males who were tested to the constituents of the fragrance mix. During the period of the study the incidence of positive tests to oak moss increased by 5% yearly (P = 0.001, 95% CI 2.2-8.7). The frequency of allergic reactions to eugenol and geraniol remained relatively constant. Isoeugenol and alpha-amyl cinnamic aldehyde sensitivity increased and hydroxycitronellal showed a slow decline. There was a striking reduction in the frequency of sensitivity to cinnamic aldehyde (by 18% yearly; P < 0.001, 95% CI 14.3-21.0) and cinnamic alcohol (by 9% yearly; P < 0.001, 95% CI 5.2-12.9); these are now uncommon fragrance allergens. These data show temporal trends which may reflect the frequency of population exposure to individual fragrances.

  7. Response to rivastigmine transdermal patch or memantine plus rivastigmine patch is affected by apolipoprotein E genotype in Alzheimer patients.

    PubMed

    Han, Hyun Jeong; Kim, Byeong C; Lee, Jun-Young; Ryu, Seung-Ho; Na, Hae Ri; Yoon, Soo Jin; Park, Hyun Young; Shin, Joon Hyun; Cho, Soo-Jin; Yi, Hyon-Ah; Choi, Mun Seong; Heo, Jae-Hyeok; Park, Kyung Won; Kim, Kwang K; Choi, Seong Hye

    2012-01-01

    The apolipoprotein E (APOE) genotype in response to pharmacological treatments in patients with Alzheimer's disease (AD) remains a matter of controversy. This analysis investigated the effect of the APOE genotype on the clinical response to rivastigmine transdermal patch monotherapy or memantine plus rivastigmine patch in patients with mild to moderate AD. Two hundred and six (n = 206) patients with probable AD and Mini-Mental State Examination (MMSE) scores of 10-20 were randomized to rivastigmine patch monotherapy or memantine plus rivastigmine patch for 24 weeks. Of the 206 patients with probable AD, 146 patients who consented to genetic testing for APOE were included and assessed for this subgroup study. There were no significant differences on MMSE, NPI, ADAS-cog, ADCS-ADL, CDR-SB, NPI and FAB between rivastigmine patch monotherapy and memantine plus rivastigmine patch according to the APOE genotype. However, patients with moderately severe AD (MMSE ≤15) who were APOE ε4 carriers showed higher responder rates on ADCS-ADL with memantine plus rivastigmine patch compared to rivastigmine patch monotherapy. Moderately severe AD patients with the APOE ε4 allele may respond more favorably to memantine plus rivastigmine patch than ε4 noncarriers. Copyright © 2012 S. Karger AG, Basel.

  8. Winter season, frequent hand washing, and irritant patch test reactions to detergents are associated with hand dermatitis in health care workers.

    PubMed

    Callahan, Adrienne; Baron, Elma; Fekedulegn, Desta; Kashon, Michael; Yucesoy, Berran; Johnson, Victor J; Domingo, Diana Santo; Kirkland, Brent; Luster, Michael I; Nedorost, Susan

    2013-01-01

    Irritant hand dermatitis (IHD) is common in health care workers. We studied endogenous irritant contact dermatitis threshold by patch testing and exogenous factors such as season and hand washing for their association with IHD in health care workers. Irritant patch testing with sodium lauryl sulfate (SLS), sodium hydroxide, and benzalkonium chloride at varying concentrations was measured in 113 health care workers. Examination for hand dermatitis occurred at 1-month intervals for a period of 6 months in the Midwestern United States. Positive patch testing to low-concentration SLS was associated with IHD (P = 0.0310) after adjusting for age, sex, ethnicity, season, history of childhood flexural dermatitis, mean indoor relative humidity, and glove and hand sanitizer usage. Subjects with a positive patch test to SLS were 78% more likely to have occurrence of IHD (incidence rate ratio [IRR] = 1.78; 95% confidence interval [CI], 0.92-3.45). Hand washing frequency (≥10 times a day; IRR = 1.55; 95% CI, 1.01-2.39) and cold season (IRR = 2.76; 95% CI, 1.35-5.65) were associated with IHD. No association was found between history of childhood flexural dermatitis and IHD in this population. Both genetic and environmental factors are important in the etiology of IHD and should be considered in designing strategies to protect, educate, and treat susceptible individuals.

  9. Clinical relevance of positive patch test reactions to the 26 EU-labelled fragrances.

    PubMed

    van Oosten, Eleonoor J; Schuttelaar, Marie-Louise A; Coenraads, Pieter Jan

    2009-10-01

    Fragrance mix I (FM I) and fragrance mix II (FM II) in the European baseline series are used as screening tools for fragrance contact allergy. In 2005 the European Union (EU) required labelling of 26 fragrances when present in cosmetic products. INCI nomenclature is obligatory for such labelling. To describe frequencies of contact allergy to these 26 fragrance substances, and to evaluate clinical relevance of these positive reactions. Three hundred and twenty patients with eczema suspected of being contact allergy to fragrances or cosmetics were patch tested with the EU-declared fragrance chemicals, FM I and FM II. There were 76 positive reactions in 33 patients. Most reactions were seen to [corrected] hydroxyisohexyl 3-cyclohexene carboxaldehyde in 3.1%, followed by Evernia furfuracea (2.5%) and cinnamyl alcohol (2.5%). Twelve reactions to FM I and II were not confirmed by separate ingredients. Clinical relevance of positive reactions to fragrances was certain in 20/33 (61%). 10.3% of the patients had positive patch tests in the EU-list. Hydroxyisohexyl 3-cyclohexene carboxaldehyde, a component of FM II, was the most frequent allergen, followed by Evernia furfuracea. Since Evernia furfuracea is not part of FM I or FM II, relevant reactions can be missed when only the European baseline series is used.

  10. Adding Insult to Imagery? Art Education and Censorship

    ERIC Educational Resources Information Center

    Sweeny, Robert W.

    2007-01-01

    The "Adding Insult to Imagery? Artistic Responses to Censorship and Mass-Media" exhibition opened in January 16, 2006, Kipp Gallery on the Indiana University of Pennsylvania campus. Eleven gallery-based works, 9 videos, and 10 web-based artworks comprised the show; each dealt with the relationship between censorship and mass mediated…

  11. AGING AND ANIMAL MODELS OF SYSTEMIC INSULT: TRAUMA, BURN, AND SEPSIS

    PubMed Central

    Nomellini, Vanessa; Gomez, Christian R.; Gamelli, Richard L.

    2010-01-01

    In the acute-care setting, it is widely accepted that elderly patients have increased morbidity and mortality compared with young healthy patients. The reasons for this, however, are largely unknown. Although animal modeling has helped improve treatment strategies for young patients, there are a scarce number of studies attempting to understand the mechanisms of systemic insults such as trauma, burn, and sepsis in aged individuals. This review aims to highlight the relevance of using animals to study the pathogenesis of these insults in the aged and, despite the deficiency of information, to summarize what is currently known in this field. PMID:18636047

  12. Preparation of an oakmoss absolute with reduced allergenic potential.

    PubMed

    Ehret, C; Maupetit, P; Petrzilka, M; Klecak, G

    1992-06-01

    Synopsis Oakmoss absolute, an extract of the lichen Evernia prunastri, is known to cause allergenic skin reactions due to the presence of certain aromatic aldehydes such as atranorin, chloratranorin, ethyl hematommate and ethyl chlorohematommate. In this paper it is shown that treatment of Oakmoss absolute with amino acids such as lysine and/or leucine, lowers considerably the content of these allergenic constituents including atranol and chloratranol. The resulting Oakmoss absolute, which exhibits an excellent olfactive quality, was tested extensively in comparative studies on guinea pigs and on man. The results of the Guinea Pig Maximization Test (GPMT) and Human Repeated Insult Patch Test (HRIPT) indicate that, in comparison with the commercial test sample, the allergenicity of this new quality of Oakmoss absolute was considerably reduced, and consequently better skin tolerance of this fragrance for man was achieved.

  13. Repeat GED[R] Tests Examinees: Who Persists and Who Passes? GED Testing Service [R]Research Studies, 2010-2

    ERIC Educational Resources Information Center

    Zhang, Jizhi; Patterson, Margaret Becker

    2010-01-01

    Like most high-stakes testing programs, the GED[R] testing program allows examinees who do not pass on the first attempt to retake the GED Tests. Studies and reports have described GED Tests candidates' characteristics and testing performance, but no study has targeted repeat examinees. A series of questions related to repeat examinees remains…

  14. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    PubMed

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  15. [Results of patch tests using basic allergens in construction workers].

    PubMed

    Kieć-Swierczyńska, M

    1983-01-01

    A group of 853 construction industry workers exposed to irritants and allergens (mainly cement, lime, sand, water, lubricants and antiadhesive oils and a control group of 74 subjects (sawers) underwent patch tests after Jadassohn--Bloch with seven allergens most common in the construction industry working environment (compounds of chromium, nickel and cobalt, turpentine and three rubber allergens--mercantobenzothiazole, thiocarbamoyl and diphenylguanidine). Allergy was found in 25.5% of the construction industry workers, in this 7.7% were those with eczema and dermatitis, 17.8%--those with latent allergy (in 12.2% allergy was accompanied by dermatoses of non-allergic etiology, 5.6% construction workers no skin changes). The highest number of skin positive tests was that with chromium (22.4% of affected workers) and cobalt (12.4%). Most susceptible to allergy were: painters, bricklayers, carpenters, joiners, reinforcing concretors, terrazers, concretors, electricians, smiths and reinforcers. In addition, allergy was found to be dependent on age and length of employment.

  16. Reliability and criterion-related validity of a new repeated agility test

    PubMed Central

    Makni, E; Jemni, M; Elloumi, M; Chamari, K; Nabli, MA; Padulo, J; Moalla, W

    2016-01-01

    The study aimed to assess the reliability and the criterion-related validity of a new repeated sprint T-test (RSTT) that includes intense multidirectional intermittent efforts. The RSTT consisted of 7 maximal repeated executions of the agility T-test with 25 s of passive recovery rest in between. Forty-five team sports players performed two RSTTs separated by 3 days to assess the reliability of best time (BT) and total time (TT) of the RSTT. The intra-class correlation coefficient analysis revealed a high relative reliability between test and retest for BT and TT (>0.90). The standard error of measurement (<0.50) showed that the RSTT has a good absolute reliability. The minimal detectable change values for BT and TT related to the RSTT were 0.09 s and 0.58 s, respectively. To check the criterion-related validity of the RSTT, players performed a repeated linear sprint (RLS) and a repeated sprint with changes of direction (RSCD). Significant correlations between the BT and TT of the RLS, RSCD and RSTT were observed (p<0.001). The RSTT is, therefore, a reliable and valid measure of the intermittent repeated sprint agility performance. As this ability is required in all team sports, it is suggested that team sports coaches, fitness coaches and sports scientists consider this test in their training follow-up. PMID:27274109

  17. Positive relationship-intensity of response to p-phenylenediamine on patch testing and cross-reactions with related allergens.

    PubMed

    Thomas, Bjorn R; White, Ian R; McFadden, John P; Banerjee, Piu

    2014-08-01

    Hair dye exposure is the most common cause of sensitization to p-phenylenediamine (PPD). Cross-reactions with structurally related allergens occur. It is suggested that a stronger patch test reaction (3+ rather than 1+) to PPD (usually tested as 1% petrolatum) is associated with an increased propensity for cross-reactions. In this article we will demonstrate this association. Of 230 patients with allergic reactions to PPD on patch testing identified during 2007-2012 from clinical records, notes for 221 were available for review. Data were collected regarding age, sex, and grade of reaction [International Contact Dermatitis Research Group (ICDRG) criteria] to PPD. Cross-reactions with the following allergens, found in our baseline series, were recorded: Disperse Yellow 3, N-isopropyl-N'-phenyl-p-phenylenediamine (IPPD), and caine mix. Having excluded 23 doubtful reactions, the reactions from 198 patients were further considered. Of the patients, 75.3% (n = 149) were female, and the mean age was 48.6 years (12-82 years). Of the patients allergic to PPD, 16.6% (n = 33) showed cross-reactions with one or more related allergens. Cross-reactions were seen in 16% with a grade of 1+, 14.5% with a grade of 2+, 28.6% with a grade of 3+ when PPD was tested 1% pet., and 50.0% when PPD was tested at 0.1-0.001%, arbitrarily considered to be 4+ (p = 0.02; Cramér's V = 0.23). An increasing likelihood of reactions to Disperse Yellow 3, IPPD or caine mix was seen with increasing strength of patch test reaction to PPD. The clinical relevance of these cross-reactions is unclear. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society.

    PubMed

    Schalock, Peter C; Crawford, Glen; Nedorost, Susan; Scheinman, Pamela L; Atwater, Amber Reck; Mowad, Christen; Brod, Bruce; Ehrlich, Alison; Watsky, Kalman L; Sasseville, Denis; Silvestri, Dianne; Worobec, Sophie M; Elliott, John F; Honari, Golara; Powell, Douglas L; Taylor, James; DeKoven, Joel

    2016-01-01

    The American Contact Dermatitis Society recognizes the interest in the evaluation and management of metal hypersensitivity reactions. Given the paucity of robust evidence with which to guide our practices, we provide reasonable evidence and expert opinion-based guidelines for clinicians with regard to metal hypersensitivity reaction testing and patient management. Routine preoperative evaluation in individuals with no history of adverse cutaneous reactions to metals or history of previous implant-related adverse events is not necessary. Patients with a clear self-reported history of metal reactions should be evaluated by patch testing before device implant. Patch testing is only 1 element in the assessment of causation in those with postimplantation morbidity. Metal exposure from the implanted device can cause sensitization, but a positive metal test does not prove symptom causality. The decision to replace an implanted device must include an assessment of all clinical factors and a thorough risk-benefit analysis by the treating physician(s) and patient.

  19. LabPatch, an acquisition and analysis program for patch-clamp electrophysiology.

    PubMed

    Robinson, T; Thomsen, L; Huizinga, J D

    2000-05-01

    An acquisition and analysis program, "LabPatch," has been developed for use in patch-clamp research. LabPatch controls any patch-clamp amplifier, acquires and records data, runs voltage protocols, plots and analyzes data, and connects to spreadsheet and database programs. Controls within LabPatch are grouped by function on one screen, much like an oscilloscope front panel. The software is mouse driven, so that the user need only point and click. Finally, the ability to copy data to other programs running in Windows 95/98, and the ability to keep track of experiments using a database, make LabPatch extremely versatile. The system requirements include Windows 95/98, at least a 100-MHz processor and 16 MB RAM, a data acquisition card, digital-to-analog converter, and a patch-clamp amplifier. LabPatch is available free of charge at http://www.fhs.mcmaster.ca/huizinga/.

  20. The effect of transdermal nicotine patches on sleep and dreams.

    PubMed

    Page, F; Coleman, G; Conduit, R

    2006-07-30

    This study was undertaken to determine the effect of 24-h transdermal nicotine patches on sleep and dream mentation in 15 smokers aged 20 to 33. Utilising a repeated measures design, it was found that more time awake and more ASDA micro-arousals occurred while wearing the nicotine patch compared to placebo. Also, the percentage of REM sleep decreased, but REM latency and the proportion of time spent in NREM sleep stages did not change significantly. Dream reports containing visual imagery, visual imagery ratings and the number of visualizable nouns were significantly greater from REM compared to Stage 2 awakenings, regardless of patch condition. However, a general interaction effect was observed. Stage 2 dream variables remained equivalent across nicotine and placebo conditions. Within REM sleep, more dream reports containing visual imagery occurred while wearing the nicotine patch, and these were rated as more vivid. The greater frequency of visual imagery reports and higher imagery ratings specifically from REM sleep suggests that previously reported dreaming side effects from 24-h nicotine patches may be specific to REM sleep. Combined with previous animal studies showing that transdermally delivered nicotine blocks PGO activity in REM sleep, the current results do no appear consistent with PGO-based hypotheses of dreaming, such as the Activation-Synthesis (AS) or Activation, Input and Modulation (AIM) models.

  1. The MOAHLFA index of irritant sodium lauryl sulfate reactions: first results of a multicentre study on routine sodium lauryl sulfate patch testing.

    PubMed

    Uter, Wolfgang; Geier, Johannes; Becker, Detlef; Brasch, Jochen; Löffler, Harald

    2004-01-01

    In a multicentre study of the German Contact Dermatitis Research Group, sodium lauryl sulfate (SLS) 0.25% and 0.5% aq. has been added to routine allergen patch tests to assess its properties as a convenient diagnostic indicator of individual susceptibility to irritation at the time of patch testing. Previous studies indicated that irritant SLS reactivity may be related to individual factors such as age and sex. As these factors are, in turn, among the important predictors of contact allergy to many allergens, e.g. summarized in the 'MOAHLFA index', the impact of the MOAHLFA factors on irritant SLS patch test reactivity, and thus a potential for confounding, was assessed in the 5971 participating patients. As a result of 2 logistic regression analyses with an irritant reaction to 0.25% and 0.5% SLS, respectively, as outcome, male sex was identified as a relatively weak but significant risk factor (OR 1.38), while age 40 years or older was an even weaker risk factor (OR 1.22 and 1.15, respectively). Upon detailed analysis, no clear age gradient could, however, be identified. 1-day exposure time almost halved the odds of an irritant SLS reaction. In conclusion, this type of SLS patch test can be regarded as robust, indicating individual irritability relatively independent from the individual factors analysed here.

  2. Patch size and landscape effects on density and nesting success of grassland birds

    USGS Publications Warehouse

    Winter, Maiken; Johnson, Douglas H.; Shaffer, Jill A.; Donovan, Therese M.; Svedarsky, W. Daniel

    2006-01-01

    Current management recommendations for grassland birds in North America emphasize providing large patches of grassland habitat within landscapes that have few forest or shrubland areas. These Bird Conservation Areas are being proposed under the assumption that large patches of habitat in treeless landscapes will maintain viable populations of grassland birds. This assumption requires that patch size and landscape features affect density and nesting success of grassland birds, and that these effects are consistent among years and regions and across focal species. However, these assumptions have not yet been validated for grassland birds, and the relative importance of local vegetation structure, patch size, and landscape composition on grassland bird populations is not well known. In addition, factors influencing grassland bird nesting success have been investigated mostly in small-scale and short-duration studies. To develop management guidelines for grassland birds, we tested the spatial and temporal repeatability of the influence of patch size and landscape composition on density and nesting success of 3 grassland passerines, after controlling for local-scale vegetation structure, climate, and—when analyzing nest success—bird density. We conducted our study during 4 years (1998–2001) in 44 study plots that were set up in 3 regions of the northern tallgrass prairie in Minnesota and North Dakota, USA. In these study plots we measured density and nesting success of clay-colored sparrows (Spizella pallida), Savannah sparrows (Passerculus sandwichensis), and bobolinks (Dolichonyx oryzivorus). Statistical models indicated that density was influenced by patch size, landscape, region, and local vegetation structure more so than by local vegetation structure alone. Both magnitude and direction of the response of density to patch size varied among regions, years, and species. In contrast, the direction of landscape effects was consistent among regions, years, and

  3. Effects of blur and repeated testing on sensitivity estimates with frequency doubling perimetry.

    PubMed

    Artes, Paul H; Nicolela, Marcelo T; McCormick, Terry A; LeBlanc, Raymond P; Chauhan, Balwantray C

    2003-02-01

    To investigate the effect of blur and repeated testing on sensitivity with frequency doubling technology (FDT) perimetry. One eye of 12 patients with glaucoma (mean deviation [MD] mean, -2.5 dB, range +0.5 to -4.3 dB) and 11 normal control subjects underwent six consecutive tests with the FDT N30 threshold program in each of two sessions. In session 1, blur was induced by trial lenses (-6.00, -3.00, 0.00, +3.00, and +6.00 D, in random order). In session 2, only the effects of repeated testing were evaluated. The MD and pattern standard deviation (PSD) indices were evaluated as functions of blur and of test order. By correcting the data of session 1 for the reduction of sensitivity with repeated testing (session 2), the effect of blur on FDT sensitivities was established, and its clinical consequences evaluated on total- and pattern-deviation probability maps. FDT sensitivities decreased with blur (by <0.5 dB/D) and with repeated testing (by approximately 2 dB between the first and sixth tests). Blur and repeated testing independently led to larger numbers of locations with significant total and pattern deviation. Sensitivity reductions were similar in normal control subjects and patients with glaucoma, at central and peripheral test locations and at locations with high and low sensitivities. However, patients with glaucoma showed larger deterioration in the total-deviation-probability maps. To optimize the performance of the device, refractive errors should be corrected and immediate retesting avoided. Further research is needed to establish the cause of sensitivity loss with repeated FDT testing.

  4. Eosinophilic airway disease in a patient with a negative skin prick test, but a positive patch test with platinum salts--implications for medical surveillance.

    PubMed

    Merget, Rolf; Fartasch, Manigé; Sander, Ingrid; Van Kampen, Vera; Raulf, Monika; Brüning, Thomas

    2015-09-01

    We present the case of a 52-year-old woman with a topic dermatitis since adolescence who developed work-related hand eczema, cough and runny nose 12 years after she had started working as a laboratory technician at a precious metals refinery. While skin prick test with sodium hexachloroplatinate (SPTPt ) was negative, patch testing with ammonium tetrachloroplatinate was positive after 24, 48, 72, and 96 hr. Inhalation challenge with sodium hexachloroplatinate yielded cough, mild shortness of breath, and a maximal decrease of FEV1 of 8% from baseline 24 hr after the challenge. Significant increases of bronchial hyperresponsiveness, exhaled nitric monoxide and sputum eosinophils were documented after the challenge. We conclude that eosinophilic airway disease due to platinum salts may occur in SPTPt negative subjects. Both, patch testing and inhalation challenge with platinum salts should be considered in SPT negative subjects with occupational exposure to precious metal salts and work-related allergic symptoms. © 2015 Wiley Periodicals, Inc.

  5. Beating and insulting children as a risk for adult cancer, cardiac disease and asthma.

    PubMed

    Hyland, Michael E; Alkhalaf, Ahmed M; Whalley, Ben

    2013-12-01

    The use of physical punishment for children is associated with poor psychological and behavioral outcomes, but the causal pathway is controversial, and the effects on later physical health unknown. We conducted a cross-sectional survey of asthma, cancer, and cardiac patients (150 in each category, 75 male) recruited from outpatient clinics and 250 healthy controls (125 male). All participants were 40-60 years old and citizens of Saudi Arabia, where the use of beating and insults is an acceptable parenting style. Demographic data and recalled frequency of beatings and insults as a child were assessed on an 8-point scale. Beating and insults were highly correlated (ρ = 0.846). Propensity score matching was used to control for demographic differences between the disease and healthy groups. After controlling for differences, more frequent beating (once or more per month) and insults were associated with a significantly increased risk for cancer (RR = 1.7), cardiac disease (RR = 1.3) and asthma (RR = 1.6), with evidence of increased risk for cancer and asthma with beating frequency of once every 6 months or more. Our results show that a threatening parenting style of beating and insults is associated with increased risk for somatic disease, possibly because this form of parenting induces stress. Our findings are consistent with previous research showing that child abuse and other early life stressors adversely affect adult somatic health, but provide evidence that the pathogenic effects occur also with chronic minor stress. A stress-inducing parenting style, even when normative, has long term adverse health consequences.

  6. Scopolamine Transdermal Patch

    MedlinePlus

    ... the adhesive surface of the patch, the clear plastic protective strip should be peeled off and discarded. ... needed, remove the patch and dispose of it. Wrap the patch in tissue or paper to avoid ...

  7. Diclofenac Transdermal Patch

    MedlinePlus

    ... will be applying the patch. Cut open the envelope containing the patches, cutting on the dotted line ... it. Pull apart the zipper seal on the envelope and remove one patch. Reseal the envelope by ...

  8. Repeat HIV Testing at Voluntary Testing and Counseling Centers in Croatia: Successful HIV Prevention or Failure to Modify Risk Behaviors?

    PubMed Central

    Matković Puljić, Vlatka; Kosanović Ličina, Mirjana Lana; Kavić, Marija; Nemeth Blažić, Tatjana

    2014-01-01

    HIV testing plays a critical role in preventing the spread of the virus and identifying infected individuals in need of care. Voluntary counseling and testing centers (VCTs) not only conduct testing but they also provide counseling. Since a proportion of people who test negative for HIV on their previous visit will return for retesting, the frequency of retesting and the characteristics of those who retest may provide insights into the efficacy of testing and counseling strategies. In this cross-sectional, retrospective study of 1,482 VCT clients in Croatia in 2010, 44.3% had been tested for HIV before. The rate of repeat HIV testing is lower in Croatia than in other countries. Men who have sex with men (MSM) clients, those with three or more sexual partners in the last 12 months, consistent condom users with steady partners, and intravenous drug users were more likely to be repeat testers. This finding suggests that clients presenting for repeat HIV testing are those who self-identify as being at a higher risk of infection. Our data showed that testing positive for HIV was not associated with repeat testing. However, the effects of repeat testing on HIV epidemiology needs to be explored. PMID:24705595

  9. Coevolution of patch-type dependent emigration and patch-type dependent immigration.

    PubMed

    Weigang, Helene C

    2017-08-07

    The three phases of dispersal - emigration, transfer and immigration - are affecting each other and the former and latter decisions may depend on patch types. Despite the inevitable fact of the complexity of the dispersal process, patch-type dependencies of dispersal decisions modelled as emigration and immigration are usually missing in theoretical dispersal models. Here, I investigate the coevolution of patch-type dependent emigration and patch-type dependent immigration in an extended Hamilton-May model. The dispersing population inhabits a landscape structured into many patches of two types and disperses during a continuous-time season. The trait under consideration is a four dimensional vector consisting of two values for emigration probability from the patches and two values for immigration probability into the patches of each type. Using the adaptive dynamics approach I show that four qualitatively different dispersal strategies may evolve in different parameter regions, including a counterintuitive strategy, where patches of one type are fully dispersed from (emigration probability is one) but individuals nevertheless always immigrate into them during the dispersal season (immigration probability is one). I present examples of evolutionary branching in a wide parameter range, when the patches with high local death rate during the dispersal season guarantee a high expected disperser output. I find that two dispersal strategies can coexist after evolutionary branching: a strategy with full immigration only into the patches with high expected disperser output coexists with a strategy that immigrates into any patch. Stochastic simulations agree with the numerical predictions. Since evolutionary branching is also found when immigration evolves alone, the present study is adding coevolutionary constraints on the emigration traits and hence finds that the coevolution of a higher dimensional trait sometimes hinders evolutionary diversification. Copyright © 2017

  10. Repeatability of testing procedures for resilient modulus and fatigue : appendices.

    DOT National Transportation Integrated Search

    1989-04-01

    The article is the appendices of "Repeatability of testing procedures for resilient modulus and fatigue". : Extensive use of diametral resilient modulus and fatigue testing is made by the Oregon State Highway Division to evaluate asphaltic concrete m...

  11. Pretreatment of pericardial patches with antibiotics does not alter patch healing in vivo.

    PubMed

    Bai, Hualong; Kuwahara, Go; Wang, Mo; Brownson, Kirstyn E; Foster, Trenton R; Yamamoto, Kota; Xing, Ying; Dardik, Alan

    2016-04-01

    Pretreatment with antibiotics is commonly performed before surgical implantation of prosthetic materials. We previously showed that pericardial patches are infiltrated by macrophages and arterial stem cells after implantation into an artery. We hypothesized that antibiotic pretreatment would diminish the number of cells infiltrating into the patch, potentially affecting early neointimal formation. Bovine pericardial patches were pretreated with saline, bacitracin (500 U/mL), or cephalexin (10 mg/mL) for 30 minutes before implantation into the Wistar rat infrarenal aorta. Patches were retrieved on day 7 or day 30 and analyzed for histology and cell infiltration. Markers of proliferation, apoptosis, vascular cell identity, and M1 and M2 macrophage subtypes were examined using immunofluorescence and immunohistochemistry. Extracted proteins were analyzed by Western blot. At day 7, pericardial patches pretreated with bacitracin or cephalexin showed similar amounts of neointimal thickening (P = .55) and cellular infiltration (P = .42) compared with control patches. Patches pretreated with antibiotics showed similar proliferation (P = .09) and apoptosis (P = .84) as control patches. The cell composition of the neointima in pretreated patches was similar to control patches, with a thin endothelial layer overlying a thin layer of smooth muscle cells (P = .45), and containing similar numbers of CD34-positive (P = .26) and vascular endothelial growth factor receptor 2-positive (P = .31) cells. Interestingly, within the body of the patch, there were fewer macrophages (P = .0003) and a trend towards fewer endothelial progenitor cells (P = .051). No M1 macrophages were found in or around any of the patches. M2 macrophages were present around the patches, and there was no difference in numbers of M2 macrophages surrounding control patches and patches pretreated with antibiotics (P = .24). There was no difference in neointimal thickness at day 30 between control

  12. Granisetron Transdermal Patch

    MedlinePlus

    ... patch. Each patch is stuck onto a thin plastic liner and a separate rigid plastic film. Do not open the pouch in advance, ... cut the patch into pieces. Peel the thin plastic liner off of the printed side of the ...

  13. Lidocaine Transdermal Patch

    MedlinePlus

    ... It works by stopping nerves from sending pain signals. ... time and the length of time you may wear the patches. Never apply more than three patches at one time, and never wear patches for more than 12 hours per day. ...

  14. The rise in carboxyhemoglobin from repeated pulmonary diffusing capacity tests.

    PubMed

    Zavorsky, Gerald S

    2013-03-01

    The purpose of this study determined the rise in carboxyhemoglobin percentage (COHb) from repeated pulmonary diffusing capacity tests using 5 or 10s single breath-hold maneuvers. Five male and four female non-smokers [baseline COHb=1.2 (SD 0.5%)] performed repeated pulmonary diffusing capacity testing on two separate days. The days were randomized to either repeated 10s (0.28% CO), or 5s (0.28% CO, 55ppm NO) breath-hold maneuvers. Twenty-two 5s breath-hold maneuvers, each separated by 4min rest, raised COHb to 11.1 (1.4)% and minimally raised the methemoglobin percentage (METHb) by 0.3 (0.2)% to a value of 0.8 (0.2)%. After the 22nd test, pulmonary diffusing capacity for carbon monoxide (DLCO) was reduced by about 4mL/min/mmHg, equating to a 0.44% increase in COHb per 5s breath-hold maneuver and a concomitant 0.35mL/min/mmHg decrease in DLCO. Pulmonary diffusing capacity for nitric oxide (DLNO) was not altered after 22 tests. On another day, the 10s single breath-hold maneuver increased COHb by 0.64% per test, and reduced DLCO by 0.44mL/min/mmHg per test. In conclusion, 5s breath-hold maneuvers do not appreciably raise METHb or DLNO, and DLCO is only significantly reduced when COHb is at least 6%. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Patch test results in patients with allergic contact dermatitis in the Podlasie region

    PubMed Central

    Bacharewicz, Joanna; Pawłoś, Anna

    2013-01-01

    Introduction The aim of the study was to provide current data on the incidence of allergy to various contact allergens in patients with allergic contact eczema and the analysis of selected socio-demographic data of the patients. Material and methods The study included 1532 patients (1010 women and 522 men) treated for allergic contact dermatitis at the Department of Dermatology and Venereology and at the Dermatology Outpatient Clinic in Bialystok in 2007–2011. The assessment of selected demographic data and skin lesions was based on the MOAHFLA index, while the results of patch tests were analyzed with modified Baseline European Series consisting of 31 allergens. Results In the group of patients with eczema, 34.1% were men, and 55% of all respondents were people over 40 years of age. The occupational character of skin lesions was found in 22.5%. Most frequently (38.9%) skin lesions were localized on the hands, rarely involved legs (3.98%). Atopic dermatitis was diagnosed in 4.5% of patients. The ten most frequent allergens were: nickel sulfate (24%), cobalt chloride (15.3%), fragrance mix (8.25%), potassium dichromate (6.8%), balsam of Peru (5.5%), neomycin (4.42%), paraphenylenediamine (3.85%), Quatermium-15 (2.1%), detreomycin (1.83%) and budesonide (1.44% of tested patients). Conclusions Frequent allergy to detreomycin indicates the need of patch testing for this allergen of all examined patients with allergic contact dermatitis. The increased frequency of the nickel allergy is a worrying problem and indicates the need for education about the risk factors for nickel allergy development and the implementation of appropriate legal regulations. PMID:24493997

  16. Occupational Contact Dermatitis: Workers' Compensation Patch Test Results of Portland, Oregon, 2005-2014.

    PubMed

    Coman, Garrett; Zinsmeister, Chris; Norris, Patricia

    2015-01-01

    Workers are exposed to potential irritants and allergens with constant introduction of new industrial chemicals in the workplace. Characterize the final diagnoses, demographics, occupations, exposures, clinical presentations, patch test results, dermatologic histories, and risk factors of workers evaluated for suspected work-related allergic contact dermatitis (ACD). A retrospective chart review of 310 workers' compensation independent medical examinations evaluated for suspected work-related ACD was performed. Workers were seen in a community dermatology clinic in Portland, Oregon, from 2005 to 2014. Evaluation included history, physical examination, patch testing, and further diagnostic workup when indicated. Hand dermatitis was the most common presentation (n = 148, 47.7%). Prevalent occupations included health care workers (n = 51, 16.5%), custodial staff (n = 41, 13.2%), and machinists (n = 36, 11.6%). Allergic contact dermatitis (47.5%) was more common than irritant contact dermatitis (ICD) (38.9%) in those diagnosed as having occupational skin disease (n = 185). The highest-frequency work-related allergens were thiuram mix (21 of 88, 23.9%), carba mix (20 of 88, 22.7%), potassium dichromate (9 of 88, 10.2%), and epoxy resin (9 of 88, 10.2%). Allergic contact dermatitis and ICD are common occupational skin disorders. In this population of workers' compensation referrals, ACD was more common, with 73.3% of those cases work related, compared with 86.7% of ICD. Blue collar work and wet work were risk factors for the development of ACD and ICD.

  17. MS lesion segmentation using a multi-channel patch-based approach with spatial consistency

    NASA Astrophysics Data System (ADS)

    Mechrez, Roey; Goldberger, Jacob; Greenspan, Hayit

    2015-03-01

    This paper presents an automatic method for segmentation of Multiple Sclerosis (MS) in Magnetic Resonance Images (MRI) of the brain. The approach is based on similarities between multi-channel patches (T1, T2 and FLAIR). An MS lesion patch database is built using training images for which the label maps are known. For each patch in the testing image, k similar patches are retrieved from the database. The matching labels for these k patches are then combined to produce an initial segmentation map for the test case. Finally a novel iterative patch-based label refinement process based on the initial segmentation map is performed to ensure spatial consistency of the detected lesions. A leave-one-out evaluation is done for each testing image in the MS lesion segmentation challenge of MICCAI 2008. Results are shown to compete with the state-of-the-art methods on the MICCAI 2008 challenge.

  18. The analgesic effect of benzocaine mucoadhesive patches on orthodontic pain caused by elastomeric separators, a preliminary study.

    PubMed

    Eslamian, Ladan; Borzabadi-Farahani, Ali; Edini, Hosniye Zia; Badiee, Mohammad R; Lynch, Edward; Mortazavi, Alireza

    2013-09-01

    To study the effect of benzocaine mucoadhesive patches (20%) on orthodontic pain caused by elastomeric separators. A split-mouth design was used in 30 patients (12 female, 18 male, aged 23 ± 3.75 years). They were instructed to apply benzocaine and placebo patches randomly for right or left first permanent molars of maxillary/mandibular arches for 20 min and repeat this procedure every 6 h with a similar type patch. A 10 cm Visual Analogue Scale (VAS) was used for pain perception assessment in patients who were given benzocaine (benzocaine group) or placebo (placebo group) patches. Pain perception (VAS) was recorded immediately after separator placement and after 2, 6, 12, 18, 24, 48 and 72 h. The mean VAS (SD) for the placebo and benzocaine groups were 2.28 (1.08) and 1.63 (0.67), respectively. The pain peaked at 24 h. Significant pain perception differences were observed between groups at 2, 18, 24, 48 and 72 h. Pain perception was not different between genders or jaws investigated (p > 0.05). The Friedman test revealed significant differences in pain perception among various time intervals for benzocaine (χ (2) = 99.84, p = 0.000) and placebo (χ (2) = 102.361, p = 0.000) groups. Significant negative correlations (ρ) were found only between pain perception scores and patient's ages in the placebo group at 18 (-0.438), 24 (-0.526), 48 (-0.565) and 72 h (-0.458). The recorded mean VAS values were relatively low; however, the benzocaine 20% patches significantly reduced the post-separation orthodontic pain.

  19. Birth Control Patch

    MedlinePlus

    ... Safe Videos for Educators Search English Español Birth Control Patch KidsHealth / For Teens / Birth Control Patch What's in this article? What Is It? ... It Cost? Print What Is It? The birth control patch is a thin, beige, 1¾-inch (4½- ...

  20. Patch testing with uranyl acetate in veterans exposed to depleted uranium during the 1991 Gulf war and the Iraqi conflict.

    PubMed

    Shvartsbeyn, Marianna; Tuchinda, Papapit; Gaitens, Joanna; Squibb, Katherine S; McDiarmid, Melissa A; Gaspari, Anthony A

    2011-01-01

    The Depleted Uranium Follow-Up Program is a clinical surveillance program run by the Baltimore Veterans Affairs Medical Center since 1993 for veterans of the Gulf and Iraqi wars who were exposed to depleted uranium (DU) as a result of "friendly-fire" incidents. In 2009, 40 veterans from this cohort were screened for skin reactivity to metals by patch-testing with extended metal series and uranyl acetate (0.25%, 2.5%, and 25%). A control arm comprised 46 patients without any known occupational exposures to DU who were seen at the University of Maryland Dermatology Clinic for evaluation of allergic contact dermatitis. Excluding irritant reactions, no patch-test reactions to uranyl acetate were observed in the participants. Irritant reactions to DU were more common in the clinic cohort, likely reflective of the demographic differences between the two arms of the study. Biologic monitoring of urine uranium concentrations in the DU program participants with 24-hour urine samples showed evidence of percutaneous uranium absorption from the skin patches. We conclude that dermatitis observed in a subset of the veterans was unrelated to their military DU exposure. Our data suggest that future studies of skin testing with uranyl acetate should utilize 0.25%, the least irritating concentration.

  1. The dark side of testing memory: repeated retrieval can enhance eyewitness suggestibility.

    PubMed

    Chan, Jason C K; Lapaglia, Jessica A

    2011-12-01

    Eyewitnesses typically recount their experiences many times before trial. Such repeated retrieval can enhance memory retention of the witnessed event. However, recent studies (e.g., Chan, Thomas, & Bulevich, 2009) have found that initial retrieval can exacerbate eyewitness suggestibility to later misleading information--a finding termed retrieval-enhanced suggestibility (RES). Here we examined the influence of multiple retrieval attempts on eyewitness suggestibility to subsequent misinformation. In four experiments, we systematically varied the number of initial tests taken (between zero and six), the delay between initial testing and misinformation exposure (~30 min or 1 week), and whether initial testing was manipulated between- or within-subjects. University undergraduate students were used as participants. Overall, we found that eyewitness suggestibility increased as the number of initial tests increased, but this RES effect was qualified by the delay and by whether initial testing occurred in a within- or between-subjects manner. Specifically, the within-subjects RES effect was smaller than the between-subjects RES effect, possibly because of the influence of retrieval-induced forgetting/facilitation (Chan, 2009) when initial testing was manipulated within subjects. Moreover, consistent with the testing effect literature (Roediger & Karpicke, 2006), the benefits of repeated testing on later memory were stronger after a 1-week delay than after a 30-min delay, thus reducing the negative impact of RES in long-term situations. These findings suggest that conditions that are likely to occur in criminal investigations can either increase (repeated testing) or reduce (delay) the influence of RES, thus further demonstrating the complex relationship between eyewitness memory and repeated retrieval.

  2. Occupational Contact Dermatitis in Mechanics and Repairers Referred for Patch Testing: Retrospective Analysis From the North American Contact Dermatitis Group 1998-2014.

    PubMed

    Warshaw, Erin M; Hagen, Solveig L; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel G; Belsito, Donald V; Fowler, Joseph F; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Zirwas, Matthew J; Storrs, Frances J

    Contact dermatoses are common in mechanic and repair occupations. This study aimed to (1) estimate the prevalence of occupationally related contact dermatitis among mechanics/repairers patch tested from 1998 to 2014 by the North American Contact Dermatitis Group, (2) characterize responsible allergens and irritants, and their sources, and (3) compare results among 3 occupational subgroups (mechanics, electrical/electronic, and other). A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1998 and 2014. Of 38,784 patients patch tested, 691 (1.8%) were mechanics/repairers. Male sex (93.5%) and hand involvement (59.5%) were common overall. Occupationally related skin disease was more prevalent among vehicle and mobile equipment mechanics/repairers (52.7%) and other mechanics/repairers (41.4%) than electrical/electronic equipment mechanics/repairers (21.3%). Overall, carba mix, thiuram mix, and methylchloroisothiazolone/methylisothiazolone were the most common occupation-related clinically relevant allergens. Gloves, automotive vehicles, solvents, oils, lubricants, and fuels were the most common sources of responsible allergens. Common occupationally related allergens included rubber accelerators and the preservative methylchloroisothiazolone/methylisothiazolone.

  3. Profile of irritant patch testing with detergents: sodium lauryl sulfate, sodium laureth sulfate and alkyl polyglucoside.

    PubMed

    Löffler, H; Happle, R

    2003-01-01

    The cutaneous reaction to detergents follows distinct kinetic rules: the duration of application and the irritant concentration are of major importance. The aim of this study was to evaluate the differences in kinetics of skin reaction between the standard irritant sodium lauryl sulfate (SLS), and 2 modern detergents: sodium laureth sulfate (SLES) and alkyl polyglucoside (APG). We performed patch testing with SLS and SLES (or APG) at different concentrations (0.125, 0.25, 0.5, 1.0 and 2.0%) and with different exposure times (6, 12 and 24 h). Evaluation was conducted by measurement of transepidermal water loss (TEWL) and laser Doppler flowmetry (LD) 24 h, 7 and 10 days after patch removal. We found a pronounced reaction to SLS, and a far milder one to SLES. Even at the highest concentration the skin reaction to APG was hard to detect. During the regeneration period (day 3-10) SLS showed even at day 10 an increased TEWL at all concentrations tested. The irritation due to SLES was convincingly detectable only up to day 7, whereas the APG-tested skin areas showed no significant reaction even at day 3. These results demonstrate the improvement in reduction of skin irritation achieved by development of novel detergents.

  4. Diagnostic value of repeated ice tests in the evaluation of ptosis in myasthenia gravis.

    PubMed

    Park, Jun Young; Yang, Hee Kyung; Hwang, Jeong-Min

    2017-01-01

    Twenty-six patients with ptosis related to Myasthenia gravis (MG) and 38 controls with ptosis other than MG were included. All patients were tested with the ice test 2 times on separate days in the afternoon. The margin reflex distance (MRD) was measured before and immediately after 2-minute application of ice on the eyelids. The ice test was judged positive if there was an improvement of at least 2.0 mm of MRD after the ice test. Among the patients with negative test results, 'equivocal' was defined by improvement of MRD from at least 1.0 mm to less than 2.0 mm after the ice test. Repeated ice test results showed an agreement of 61.5% in MG, and 97.4% in nonmyasthenic ptosis. Repeated ice tests increased the sensitivity by 34.6% compared to a single test. Among the patients with repeatedly negative test results, 63.6% of those who showed equivocal results at least once turned out to be MG. Of those with repeated non-equivocal negative results, nobody turned out to be MG. There was no significant difference of the ice test results between ocular MG and generalized MG (p = 0.562).

  5. Diagnostic value of repeated ice tests in the evaluation of ptosis in myasthenia gravis

    PubMed Central

    2017-01-01

    Twenty-six patients with ptosis related to Myasthenia gravis (MG) and 38 controls with ptosis other than MG were included. All patients were tested with the ice test 2 times on separate days in the afternoon. The margin reflex distance (MRD) was measured before and immediately after 2-minute application of ice on the eyelids. The ice test was judged positive if there was an improvement of at least 2.0 mm of MRD after the ice test. Among the patients with negative test results, 'equivocal’ was defined by improvement of MRD from at least 1.0 mm to less than 2.0 mm after the ice test. Repeated ice test results showed an agreement of 61.5% in MG, and 97.4% in nonmyasthenic ptosis. Repeated ice tests increased the sensitivity by 34.6% compared to a single test. Among the patients with repeatedly negative test results, 63.6% of those who showed equivocal results at least once turned out to be MG. Of those with repeated non-equivocal negative results, nobody turned out to be MG. There was no significant difference of the ice test results between ocular MG and generalized MG (p = 0.562). PMID:28562609

  6. Risk of Neurological Insult in Competitive Deep Breath-Hold Diving.

    PubMed

    Tetzlaff, Kay; Schöppenthau, Holger; Schipke, Jochen D

    2017-02-01

    It has been widely believed that tissue nitrogen uptake from the lungs during breath-hold diving would be insufficient to cause decompression stress in humans. With competitive free diving, however, diving depths have been ever increasing over the past decades. A case is presented of a competitive free-diving athlete who suffered stroke-like symptoms after surfacing from his last dive of a series of 3 deep breath-hold dives. A literature and Web search was performed to screen for similar cases of subjects with serious neurological symptoms after deep breath-hold dives. A previously healthy 31-y-old athlete experienced right-sided motor weakness and difficulty speaking immediately after surfacing from a breathhold dive to a depth of 100 m. He had performed 2 preceding breath-hold dives to that depth with surface intervals of only 15 min. The presentation of symptoms and neuroimaging findings supported a clinical diagnosis of stroke. Three more cases of neurological insults were retrieved by literature and Web search; in all cases the athletes presented with stroke-like symptoms after single breath-hold dives of depths exceeding 100 m. Two of these cases only had a short delay to recompression treatment and completely recovered from the insult. This report highlights the possibility of neurological insult, eg, stroke, due to cerebral arterial gas embolism as a consequence of decompression stress after deep breath-hold dives. Thus, stroke as a clinical presentation of cerebral arterial gas embolism should be considered another risk of extreme breath-hold diving.

  7. Patch based predation in a southern Appalachian stream

    Treesearch

    C.A. Gibson; R.E. Ratajezak; G.D. Grossman

    2004-01-01

    Streams are characterized by high degrees of patchiness that could influence the role of predators in these systems. Here we assess the impact of predatory benthic fishes on benthic macroinvertebrate density, biomass, and community structure at the patch scale in a fourth order stream in the southern Appalachians. We tested the role of predation in two different patch...

  8. Chamber Tests with Human Subjects XX. Hypersensitivity to H as Demonstrated by Patch Tests Before and After Chamber Exposure to H Vapor

    DTIC Science & Technology

    1946-05-15

    worn. In addition to erythema, edema and/or folliculitis were observed in only 2 of 230 men tested prior to exposure to H vapor. After exposure, 26% of...169 men manifested edema and/or folliculitis to patch tests. These men were arbitrarily considered "sensitized". This sensitized group also showed a...for edema or folliculitis , a value CONFIDENT-L.f, - 6 - C:7 Fx was calculated in which readings of 16 were assigned their erythema value of 8 and

  9. Repeatability of a running heat tolerance test.

    PubMed

    Mee, Jessica A; Doust, Jo; Maxwell, Neil S

    2015-01-01

    At present there is no standardised heat tolerance test (HTT) procedure adopting a running mode of exercise. Current HTTs may misdiagnose a runner's susceptibility to a hyperthermic state due to differences in exercise intensity. The current study aimed to establish the repeatability of a practical running test to evaluate individual's ability to tolerate exercise heat stress. Sixteen (8M, 8F) participants performed the running HTT (RHTT) (30 min, 9 km h(-1), 2% elevation) on two separate occasions in a hot environment (40 °C and 40% relative humidity). There were no differences in peak rectal temperature (RHTT1: 38.82 ± 0.47 °C, RHTT2: 38.86 ± 0.49 °C, Intra-class correlation coefficient (ICC)=0.93, typical error of measure (TEM) = 0.13 °C), peak skin temperature (RHTT1: 38.12 ± 0.45, RHTT2: 38.11 ± 0.45 °C, ICC = 0.79, TEM = 0.30 °C), peak heart rate (RHTT1: 182 ± 15 beats min(-1), RHTT2: 183 ± 15 beats min(-1), ICC = 0.99, TEM = 2 beats min(-1)), nor sweat rate (1721 ± 675 g h(-1), 1716 ± 745 g h(-1), ICC = 0.95, TEM = 162 g h(-1)) between RHTT1 and RHTT2 (p>0.05). Results demonstrate good agreement, strong correlations and small differences between repeated trials, and the TEM values suggest low within-participant variability. The RHTT was effective in differentiating between individuals physiological responses; supporting a heat tolerance continuum. The findings suggest the RHTT is a repeatable measure of physiological strain in the heat and may be used to assess the effectiveness of acute and chronic heat alleviating procedures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. An examination of the usefulness of repeat testing practices in a large hospital clinical chemistry laboratory.

    PubMed

    Deetz, Carl O; Nolan, Debra K; Scott, Mitchell G

    2012-01-01

    A long-standing practice in clinical laboratories has been to automatically repeat laboratory tests when values trigger automated "repeat rules" in the laboratory information system such as a critical test result. We examined 25,553 repeated laboratory values for 30 common chemistry tests from December 1, 2010, to February 28, 2011, to determine whether this practice is necessary and whether it may be possible to reduce repeat testing to improve efficiency and turnaround time for reporting critical values. An "error" was defined to occur when the difference between the initial and verified values exceeded the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error limit. The initial values from 2.6% of all repeated tests (668) were errors. Of these 668 errors, only 102 occurred for values within the analytic measurement range. Median delays in reporting critical values owing to repeated testing ranged from 5 (blood gases) to 17 (glucose) minutes.

  11. Multicenter Patch Testing With a Resol Resin Based on Phenol and Formaldehyde Within the International Contact Dermatitis Research Group.

    PubMed

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus; Diepgen, Thomas; Elsner, Peter; Goossens, An; Goh, Chee-Leok; Jerajani, Hemangi; Maibach, Howard; Matsunaga, Kayoko; McFadden, John; Nixon, Rosemary; Sasseville, Denis; Bruze, Magnus

    2015-01-01

    Contact allergy to phenol-formaldehyde resins (PFRs) based on phenol and formaldehyde is not detected by a p-tertiary-butylphenol-formaldehyde resin included in most baseline patch test series. The aims of this study were to investigate the contact allergy rate to PFR-2 in an international population and to investigate associated simultaneous allergic reactions. Thirteen centers representing the International Contact Dermatitis Research Group included PFR-2 into their patch test baseline series during a period of 6 months in 2012. Of 2259 patients tested, 28 (1.2%) reacted to PFR-2. Of those 28 individuals, one had a positive reaction to formaldehyde and 2 to p-tertiary-butylphenol-formaldehyde resin. Simultaneous allergic reactions were noted to colophonium in 3, to Myroxylon pereirae in 5, and to fragrance mix I in 8. The contact allergy frequency in the tested population (1.2%) merits its inclusion into the international baseline series and possibly also into other baseline series after appropriate investigations. Significantly, overrepresented simultaneous allergic reactions were noted for M. pereirae and fragrance mix I.

  12. The Evaluation of Contact Sensitivity with Standard and Cosmetic Patch Test Series in Rosacea Patients

    PubMed Central

    Bulur, Isil; Saracoglu, Zeynep Nurhan; Bilgin, Muzaffer

    2018-01-01

    Background Rosacea is a common dermatosis characterized by erythema, telangiectasia, papules and pustules. Objective We aimed to evaluate contact sensitivity in the rosacea patients. Methods We included 65 rosacea patients and 60 healthy volunteers in the study. The patient and control groups were patch tested with European baseline series and cosmetic series. Results A positive reaction to at least 1 allergen in the European standard series was found in 32.3% of rosacea patients and 20.0% of subjects in the control group while the relevant numbers were 30.8% of rosacea patients and 10% of controls with the cosmetic series (p=0.08). In total, we found a positive reaction to at least 1 allergen in 38.5% of patients and 25.0% of controls (p=0.15). We did not find a statistically significant relationship between a positive reaction to 1 allergen in total and the gender, skin type, rosacea type, ocular involvement, age and disease duration. There were more symptoms in patients with a positive reaction to allergens (p<0.001). Conclusion Contact sensitivity was detected more common in rosacea patients. Patch testing may be useful in the treatment and follow up of rosacea patients especially if symptoms such as itching, burning and stinging are present. PMID:29853742

  13. The Evaluation of Contact Sensitivity with Standard and Cosmetic Patch Test Series in Rosacea Patients.

    PubMed

    Erdogan, Hilal Kaya; Bulur, Isil; Saracoglu, Zeynep Nurhan; Bilgin, Muzaffer

    2018-06-01

    Rosacea is a common dermatosis characterized by erythema, telangiectasia, papules and pustules. We aimed to evaluate contact sensitivity in the rosacea patients. We included 65 rosacea patients and 60 healthy volunteers in the study. The patient and control groups were patch tested with European baseline series and cosmetic series. A positive reaction to at least 1 allergen in the European standard series was found in 32.3% of rosacea patients and 20.0% of subjects in the control group while the relevant numbers were 30.8% of rosacea patients and 10% of controls with the cosmetic series ( p =0.08). In total, we found a positive reaction to at least 1 allergen in 38.5% of patients and 25.0% of controls ( p =0.15). We did not find a statistically significant relationship between a positive reaction to 1 allergen in total and the gender, skin type, rosacea type, ocular involvement, age and disease duration. There were more symptoms in patients with a positive reaction to allergens ( p <0.001). Contact sensitivity was detected more common in rosacea patients. Patch testing may be useful in the treatment and follow up of rosacea patients especially if symptoms such as itching, burning and stinging are present.

  14. Relationships Among Two Repeated Activity Tests and Aerobic Fitness of Volleyball Players.

    PubMed

    Meckel, Yoav; May-Rom, Moran; Ekshtien, Aya; Eisenstein, Tamir; Nemet, Dan; Eliakim, Alon

    2015-08-01

    The purpose of the study was to determine performance indices of a repeated sprint test (RST) and to examine their relationships with performance indices of a repeated jump test (RJT) and with aerobic fitness among trained volleyball players. Sixteen male volleyball players performed RST (6 × 30 m sprints), RJT (6 sets of 6 consecutive jumps), and an aerobic power test (20-m Shuttle Run Test). Performance indices for the RST and the RJT were (a) the ideal 30-m run time (IS), the total run time (TS) of the 6 sprints, and the performance decrement (PD) during the test and (b) the ideal jump height (IJ), the total jump height (TJ) of all the jumps, and the PD during the test, respectively. No significant correlations were found between performance indices of the RST and RJT. Significant correlations were found between PD, IS, and TS in the RST protocol and predicted peak V[Combining Dot Above]O2 (r = -0.60, -0.75, -0.77, respectively). No significant correlations were found between performance indices of the RJT (IJ, TJ, and PD) and peak V[Combining Dot Above]O2. The findings suggest that a selection of repeated activity test protocols should acknowledge the specific technique used in the sport, and that a distinct RJT, rather than the classic RST, is more appropriate for assessing the anaerobic capabilities of volleyball players. The findings also suggest that aerobic fitness plays only a minor role in performance maintenance throughout characteristic repeated jumping activity of a volleyball game.

  15. Planar patch clamp: advances in electrophysiology.

    PubMed

    Brüggemann, Andrea; Farre, Cecilia; Haarmann, Claudia; Haythornthwaite, Ali; Kreir, Mohamed; Stoelzle, Sonja; George, Michael; Fertig, Niels

    2008-01-01

    Ion channels have gained increased interest as therapeutic targets over recent years, since a growing number of human and animal diseases have been attributed to defects in ion channel function. Potassium channels are the largest and most diverse family of ion channels. Pharmaceutical agents such as Glibenclamide, an inhibitor of K(ATP) channel activity which promotes insulin release, have been successfully sold on the market for many years. So far, only a small group of the known ion channels have been addressed as potential drug targets. The functional testing of drugs on these ion channels has always been the bottleneck in the development of these types of pharmaceutical compounds.New generations of automated patch clamp screening platforms allow a higher throughput for drug testing and widen this bottleneck. Due to their planar chip design not only is a higher throughput achieved, but new applications have also become possible. One of the advantages of planar patch clamp is the possibility of perfusing the intracellular side of the membrane during a patch clamp experiment in the whole-cell configuration. Furthermore, the extracellular membrane remains accessible for compound application during the experiment.Internal perfusion can be used not only for patch clamp experiments with cell membranes, but also for those with artificial lipid bilayers. In this chapter we describe how internal perfusion can be applied to potassium channels expressed in Jurkat cells, and to Gramicidin channels reconstituted in a lipid bilayer.

  16. The identification and classification of skin irritation hazard by a human patch test.

    PubMed

    Basketter, D A; Whittle, E; Griffiths, H A; York, M

    1994-08-01

    There exist various regulatory instruments the purpose of which is to ensure that the intrinsic toxic hazards associated with substances and preparations are identified. In the context of identification of skin irritation potential, the method is normally the Draize test. Guidance notes provided by the OECD and the EEC expect that corrosive substances will have been screened out by a variety of methods. Substances or preparations which cause a sufficient degree of skin irritation will be classified as skin irritants. The primary motivation behind the present work was to introduce the concept that it is possible to assess the hazard potential of a substance or preparation to produce skin irritation in a human study. In the example presented here, 20% sodium lauryl sulfate (SLS) has been chosen as the positive control. With the protocol currently devised, occluded patch treatment with 20% SLS for up to 4 hr produces an irritant response in just over half of the panel. An irritant response is taken as a clinically evident and significant increase in erythema, oedema or dryness--a minimum of a+ reaction on the ICDRG scale. At such a level of response with the positive control (both in terms of intensity and in proportion of the panel), it is then possible to judge and/or to determine statistically, whether the test material has produced a level of skin irritation which is similar to, greater, or lower than the positive control. In this way a human patch test protocol can form a fundamental component of a strategy for the replacement of animals in determination of skin irritation and corrosion potential. By use of a careful and progressive protocol and by comparison of test data against a positive control it is both possible and practical to classify substances and preparations in terms of their skin irritation potential using that endpoint in the species of concern, man.

  17. Contact dermatitis and patch testing for the allergist.

    PubMed

    Fonacier, Luz; Noor, Irum

    2018-06-01

    To review of contact dermatitis (CD) and its key allergens and provide updates and recommendations for the practicing allergist. Through the use of various scientific search engines (eg, PubMed and MEDLINE), we reviewed literature on CD, patch tests (PTs), key allergens, occupational dermatitis, and treatment. Studies on CD, important allergens, and PTs were considered. Contact-induced dermatitis may be due to allergic CD, irritant CD, systemic CD, contact urticaria, and protein CD. Key allergens include metals (nickel, gold), topical medicaments (topical corticosteroids), and cosmetics and personal care products (fragrances and preservatives such as methyl- and methylchloro-isothiazolinone). Present relevance of a positive PT result is the combination of definite, probable, and possible relevance and should be correlated with the patient's history and physical examination. Treatment of allergic CD includes identification of relevant allergens, patient education, avoidance, and provision of alternative products the patient can use. CD is a common inflammatory skin disease and should be suspected in patients presenting with acute, subacute, or chronic dermatitis. The gold standard for diagnosing allergic CD is a PT. This article provides practical recommendations for the diagnosis and management of CD commonly seen by the allergist in their practice. Copyright © 2018 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  18. Epidural Blood Patch Using Manometry for Sinking Skin Flap Syndrome.

    PubMed

    Turner, James D; Farmer, Justin L; Dobson, Sean W

    2016-06-01

    We describe here a 55-year-old male patient with a medical history significant for chronic back pain and substance abuse with cocaine who sustained a traumatic subarachnoid hemorrhage after a fall from a roof while acutely intoxicated on cocaine requiring decompressive hemicraniectomy and cranioplasty that was complicated by an epidural abscess requiring a repeat craniectomy. He was diagnosed with sinking skin flap syndrome consistent with altered mental status and a sunken skin flap with increased midline shift. Despite treatment with Trendelenburg positioning and appropriate fluid management, the patient continued to decline, and an epidural blood patch was requested for treatment. After placement of the epidural blood patch using manometry in the epidural space, the patient's neurologic status improved allowing him to ultimately receive a cranioplasty. The patient is now able to perform several of his activities of daily living and communicate effectively.

  19. 3D printed sensing patches with embedded polymer optical fibre Bragg gratings

    NASA Astrophysics Data System (ADS)

    Zubel, Michal G.; Sugden, Kate; Saez-Rodriguez, D.; Nielsen, K.; Bang, O.

    2016-05-01

    The first demonstration of a polymer optical fibre Bragg grating (POFBG) embedded in a 3-D printed structure is reported. Its cyclic strain performance and temperature characteristics are examined and discussed. The sensing patch has a repeatable strain sensitivity of 0.38 pm/μepsilon. Its temperature behaviour is unstable, with temperature sensitivity values varying between 30-40 pm/°C.

  20. Nicotine patches improve mood and response speed in a lexical decision task.

    PubMed

    Gentry, M V; Hammersley, J J; Hale, C R; Nuwer, P K; Meliska, C J

    2000-01-01

    The effects of smoking a cigarette or wearing a transdermal nicotine patch on mood and lexical decision-making were tested in eight smokers. Each participant was tested after 4 hours of smoking abstinence, under 4 conditions: placebo (very low nicotine) cigarette, nicotine cigarette, placebo patch, and nicotine patch. Relative to placebo, wearing the nicotine patch reduced Profile of Mood States (POMS) Total Mood Disturbance and Fatigue/Inertia scores, while increasing the speed of some types of lexical decisions. Smoking a nicotine cigarette did not affect reaction times, but unexpectedly decreased the accuracy of Word/ Nonword lexical decisions. Thus, transdermal nicotine may improve mood and facilitate longterm memory search and/or attentional processes in nicotine-deprived smokers.

  1. Patch-test results in children and adolescents: systematic review of a 15-year period*

    PubMed Central

    Rodrigues, Dulcilea Ferraz; Goulart, Eugênio Marcos Andrade

    2016-01-01

    The number of studies on patch-test results in children and adolescents has gradually increased in recent years, thus stimulating reviews. This paper is a systematic review of a 15-year period devoted to studying the issue. Variations pertaining to the number and age groups of tested children and/or adolescents, the number of subjects with atopy/atopic dermatitis history, the quantity, type and concentrations of the tested substances, the test technique and type of data regarding clinical relevance, must all be considered in evaluating these studies, as they make it harder to formulate conclusions. The most common allergens in children were nickel, thimerosal, cobalt, fragrance, lanolin and neomycin. In adolescents, they were nickel, thimerosal, cobalt, fragrance, potassium dichromate, and Myroxylon pereirae. Knowledge of this matter aids health professionals in planning preventive programs aimed at improving children's quality of life and ensuring that their future prospects are not undermined. PMID:26982781

  2. Testing the role of patch openness as a causal mechanism for apparent area sensitivity in a grassland specialist.

    PubMed

    Keyel, Alexander C; Bauer, Carolyn M; Lattin, Christine R; Romero, L Michael; Reed, J Michael

    2012-06-01

    Area sensitivity, species being disproportionately present on larger habitat patches, has been identified in many taxa. We propose that some apparently area-sensitive species are actually responding to how open a habitat patch is, rather than to patch size. We tested this hypothesis for Bobolinks (Dolichonyx oryzivorus) by comparing density and occupancy to a novel openness index, patch area, and edge effects. Bobolink density and occupancy showed significant relationships with openness, but logistic models based on an openness occupancy threshold had greater explanatory power. Thresholds remained approximately consistent from June through August, and shifted to be more open in September. Variance partitioning supported the openness index as unique and relevant. We found no relationships between measures of body condition (body mass, body size, circulating corticosterone levels) and either openness or area. Our findings have implications for studies of area sensitivity, especially with regards to inconsistencies reported within species: specifically, (1) whether or not a study finds a species to be area sensitive may depend on whether small, open sites were sampled, and (2) area regressions were sensitive to observed densities at the largest sites, suggesting that variation in these fields could lead to inconsistent area sensitivity responses. Responses to openness may be a consequence of habitat selection mediated by predator effects. Finally, openness measures may have applications for predicting effects of habitat management or development, such as adding wind turbines, in open habitat.

  3. Microstrip patch antenna for simultaneous strain and temperature sensing

    NASA Astrophysics Data System (ADS)

    Mbanya Tchafa, F.; Huang, H.

    2018-06-01

    A patch antenna, consisting of a radiation patch, a dielectric substrate, and a ground plane, resonates at distinct fundamental frequencies that depend on the substrate dielectric constant and the dimensions of the radiation patch. Since these parameters change with the applied strain and temperature, this study investigates simultaneous strain and temperature sensing using a single antenna that has two fundamental resonant frequencies. The theoretical relationship between the antenna resonant frequency shifts, the temperature, and the applied strain was first established to guide the selection of the dielectric substrate, based on which an antenna sensor with a rectangular radiation patch was designed and fabricated. A tensile test specimen instrumented with the antenna sensor was subjected to thermo-mechanical tests. Experiment results validated the theoretical predictions that the normalized antenna resonant frequency shifts are linearly proportional to the applied strain and temperature changes. An inverse method was developed to determine the strain and temperature changes from the normalized antenna resonant frequency shifts, yielding measurement uncertainty of 0.4 °C and 17.22 μ \\varepsilon for temperature and strain measurement, respectively.

  4. Effects of Repeated Treadmill Testing and Electrical Stimulation on Post-Stroke Gait Kinematics

    PubMed Central

    Awad, Louis N.; Kesar, Trisha M.; Reisman, Darcy; Binder-Macleod, Stuart A.

    2012-01-01

    Improvements in task performance due to repeated testing have previously been documented in healthy and patient populations. The existence of a similar change in performance due to repeated testing has not been previously investigated at the level of gait kinematics in the post-stroke population. The presence of such changes may define the number of testing sessions necessary for measuring a stable baseline of pre-training gait performance, which is a necessary prerequisite for determining the effectiveness of gait interventions. Considering the emergence of treadmills as a popular tool for gait evaluation and retraining and the common addition of functional electrical stimulation (FES) to gait retraining protocols, the stability of gait kinematics during the repeated testing of post-stroke individuals on a treadmill, either with or without FES, needs to be determined. Nine individuals (age: 58.1 +/− 7.3 years), with hemi-paresis secondary to a stroke (onset: 7.3 +/− 6.0 years) participated in this study. An 8-camera motion analysis system was used to measure sagittal plane knee and ankle joint kinematics. Gait kinematics were compared across two (N=9) and five (N=5) testing sessions. No consistent changes in knee or ankle kinematics were observed during repeated testing. These findings indicate that clinicians and researchers may not need to spend valuable time and resources performing multiple testing and acclimatization sessions when assessing baseline gait kinematics in the post-stroke population for use in determining the effectiveness of gait interventions. PMID:22796242

  5. Atopy patch tests are useful to predict oral tolerance in children with gastrointestinal symptoms related to non-IgE-mediated cow's milk allergy.

    PubMed

    Nocerino, R; Granata, V; Di Costanzo, M; Pezzella, V; Leone, L; Passariello, A; Terrin, G; Troncone, R; Berni Canani, R

    2013-02-01

    Atopy patch tests (APTs) have been proposed for the diagnostic approach in children with non-IgE-mediated cow's milk allergy and gastrointestinal symptoms. We aimed to investigate the benefit of APTs in predicting oral tolerance in these patients. We prospectively evaluated 172 subjects with a sure diagnosis of non-IgE-mediated CMA and gastrointestinal symptoms (97 boys, 56.4%; age, 6.37 m; range, 2-12 m). At diagnosis, 113/172 (65.7%) children had positive APTs to cow's milk proteins (CMP). After 12 months of exclusion, diet APTs were repeated immediately before OFC. APTs significantly correlated (P < 0.001) with the OFC outcome (r 0.579). Diagnostic accuracy was sensitivity of 67.95%, specificity of 88.3%, PPV of 82.81%, NPV of 76.85%, and a +LR of 5.80. APTs are a valuable tool in the follow-up of children with non-IgE-mediated CMA-related gastrointestinal symptoms by contributing in determining whether an OFC can safely be undertaken. © 2012 John Wiley & Sons A/S.

  6. Efficacy of Atopy Patch Testing in Directed Dietary Therapy of Eosinophilic Esophagitis: A Pilot Study.

    PubMed

    Eckmann, Jason D; Ravi, Karthik; Katzka, David A; Davis, Dawn R; See, Jacalyn A; Geno, Debra R; Kryzer, Lori A; Alexander, Jeffrey A

    2018-03-01

    Atopy patch testing (APT) has shown potential for predicting dietary food triggers in studies of children and adolescents with eosinophilic esophagitis (EoE). To assess the efficacy of APT in adults with EoE. We conducted a prospective open-label pilot study of patients ≥ 18 years old with diagnosis of EoE at Mayo Clinic in Rochester, Minnesota, from November 2014 to January 2016. All patients underwent patch testing using intact food products, followed by a six food elimination diet and stepwise food reintroduction. Response to elimination diet was assessed with serial endoscopy with biopsies as well as clinical symptoms. APT results were directly compared to elimination diet results for assessment of efficacy. Correlation between clinical symptoms, endoscopic score, and histology was also qualitatively evaluated. Fifty percent of the patients had a positive APT, while only 16% had an APT result confirmed histologically during food reintroduction. Sensitivity of APT was calculated to be 5.9%, with specificity of 92.0%. Furthermore, we found significant qualitative inter-patient heterogeneity in the correlation between clinical symptoms, EREFS score, and histology. APT does not reliably predict food triggers identified by food elimination diet in adult patients with EoE. As a result, APT does not have a clear role in the evaluation of patients with EoE.

  7. Implementation of repeat HIV testing during pregnancy in Kenya: a qualitative study.

    PubMed

    Rogers, Anna Joy; Weke, Elly; Kwena, Zachary; Bukusi, Elizabeth A; Oyaro, Patrick; Cohen, Craig R; Turan, Janet M

    2016-07-11

    Repeat HIV testing in late pregnancy has the potential to decrease rates of mother-to-child transmission of HIV by identifying mothers who seroconvert after having tested negative for HIV in early pregnancy. Despite being national policy in Kenya, the available data suggest that implementation rates are low. We conducted 20 in-depth semi-structured interviews with healthcare providers and managers to explore barriers and enablers to implementation of repeat HIV testing guidelines for pregnant women. Participants were from the Nyanza region of Kenya and were purposively selected to provide variation in socio-demographics and job characteristics. Interview transcripts were coded and analyzed in Dedoose software using a thematic analysis approach. Four themes were identified a priori using Ferlie and Shortell's Framework for Change and additional themes were allowed to emerge from the data. Participants identified barriers and enablers at the client, provider, facility, and health system levels. Key barriers at the client level from the perspective of providers included late initial presentation to antenatal care and low proportions of women completing the recommended four antenatal visits. Barriers to offering repeat HIV testing for providers included heavy workloads, time limitations, and failing to remember to check for retest eligibility. At the facility level, inconsistent volume of clients and lack of space required for confidential HIV retesting were cited as barriers. Finally, at the health system level, there were challenges relating to the HIV test kit supply chain and the design of nationally standardized antenatal patient registers. Enablers to improving the implementation of repeat HIV testing included client dissemination of the benefits of antenatal care through word-of-mouth, provider cooperation and task shifting, and it was suggested that use of an electronic health record system could provide automatic reminders for retest eligibility. This study

  8. Fentanyl patches: preventable overdose.

    PubMed

    2010-02-01

    Fentanyl is a potent opioid analgesic marketed for the treatment of stable intense chronic pain, particularly in the form of a transdermal patch. These delivery devices carry the same risk of adverse effects and drug interactions as conventional formulations of opioids. The patches carry an added risk of fentanyl overdose because they contain very high doses, both before and after use. High-risk situations for overdose were identified by examining the results of pharmacovigilance studies and medication error prevention programmes, as well as an observational study, case reports, and a French legal action. The main situations exposing patients to a risk of overdose are: confusion between two dose strengths, forgetting to remove the patch; accidental transfer of the patch to another person, application of more than one patch, cutting the patches, self-medication, and ingestion. Increased skin temperature facilitates fentanyl absorption and thus increases the risk of overdose; high-risk situations include fever, electric blankets, and intense physical exercise. In practice, the precautions for treatment and patch disposal must be followed exactly if this delivery system is to serve as a valid alternative to morphine for selected patients with stable intense chronic pain.

  9. Triage of women with low-grade cervical lesions--HPV mRNA testing versus repeat cytology.

    PubMed

    Sørbye, Sveinung Wergeland; Arbyn, Marc; Fismen, Silje; Gutteberg, Tore Jarl; Mortensen, Elin Synnøve

    2011-01-01

    In Norway, women with low-grade squamous intraepithelial lesions (LSIL) are followed up after six months in order to decide whether they should undergo further follow-up or be referred back to the screening interval of three years. A high specificity and positive predictive value (PPV) of the triage test is important to avoid unnecessary diagnostic and therapeutic procedures. At the University Hospital of North Norway, repeat cytology and the HPV mRNA test PreTect HPV-Proofer, detecting E6/E7 mRNA from HPV types 16, 18, 31, 33 and 45, are used in triage of women with ASC-US and LSIL. In this study, women with LSIL cytology in the period 2005-2008 were included (n = 522). Two triage methods were evaluated in two separate groups: repeat cytology only (n = 225) and HPV mRNA testing in addition to repeat cytology (n = 297). Histologically confirmed cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) was used as the study endpoint. Of 522 women with LSIL, 207 had biopsies and 125 of them had CIN2+. The sensitivity and specificity of repeat cytology (ASC-US or worse) were 85.7% (95% confidence interval (CI): 72.1, 92.2) and 54.4 % (95% CI: 46.9, 61.9), respectively. The sensitivity and specificity of the HPV mRNA test were 94.2% (95% CI: 88.7, 99.7) and 86.0% (95% CI: 81.5, 90.5), respectively. The PPV of repeat cytology was 38.4% (95% CI: 29.9, 46.9) compared to 67.0% (95% CI: 57.7, 76.4) of the HPV mRNA test. HPV mRNA testing was more sensitive and specific than repeat cytology in triage of women with LSIL cytology. In addition, the HPV mRNA test showed higher PPV. These data indicate that the HPV mRNA test is a better triage test for women with LSIL than repeat cytology.

  10. Triage of Women with Low-Grade Cervical Lesions - HPV mRNA Testing versus Repeat Cytology

    PubMed Central

    Sørbye, Sveinung Wergeland; Arbyn, Marc; Fismen, Silje; Gutteberg, Tore Jarl; Mortensen, Elin Synnøve

    2011-01-01

    Background In Norway, women with low-grade squamous intraepithelial lesions (LSIL) are followed up after six months in order to decide whether they should undergo further follow-up or be referred back to the screening interval of three years. A high specificity and positive predictive value (PPV) of the triage test is important to avoid unnecessary diagnostic and therapeutic procedures. Materials and Methods At the University Hospital of North Norway, repeat cytology and the HPV mRNA test PreTect HPV-Proofer, detecting E6/E7 mRNA from HPV types 16, 18, 31, 33 and 45, are used in triage of women with ASC-US and LSIL. In this study, women with LSIL cytology in the period 2005–2008 were included (n = 522). Two triage methods were evaluated in two separate groups: repeat cytology only (n = 225) and HPV mRNA testing in addition to repeat cytology (n = 297). Histologically confirmed cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) was used as the study endpoint. Results Of 522 women with LSIL, 207 had biopsies and 125 of them had CIN2+. The sensitivity and specificity of repeat cytology (ASC-US or worse) were 85.7% (95% confidence interval (CI): 72.1, 92.2) and 54.4 % (95% CI: 46.9, 61.9), respectively. The sensitivity and specificity of the HPV mRNA test were 94.2% (95% CI: 88.7, 99.7) and 86.0% (95% CI: 81.5, 90.5), respectively. The PPV of repeat cytology was 38.4% (95% CI: 29.9, 46.9) compared to 67.0% (95% CI: 57.7, 76.4) of the HPV mRNA test. Conclusion HPV mRNA testing was more sensitive and specific than repeat cytology in triage of women with LSIL cytology. In addition, the HPV mRNA test showed higher PPV. These data indicate that the HPV mRNA test is a better triage test for women with LSIL than repeat cytology. PMID:21918682

  11. The development and reliability of a repeated anaerobic cycling test in female ice hockey players.

    PubMed

    Wilson, Kier; Snydmiller, Gary; Game, Alex; Quinney, Art; Bell, Gordon

    2010-02-01

    The purpose of this study was to develop and assess the reliability of a repeated anaerobic power cycling test designed to mimic the repeated sprinting nature of the sport of ice hockey. Nineteen female varsity ice hockey players (mean X +/- SD age, height and body mass = 21 +/- 2 yr, 166.6 +/- 6.3 cm and 62.3 +/- 7.3) completed 3 trials of a repeated anaerobic power test on a Monark cycle ergometer on different days. The test consisted of "all-out" cycling for 5 seconds separated by 10 seconds of low-intensity cycling, repeated 4 times. The relative load factor used for the resistance setting was equal to 0.095 kg per kilogram body mass. There was no significant difference between the peak 5-second power output (PO), mean PO, or the fatigue index (%) among the 3 different trials. The peak 5-second PO was 702.6 +/- 114.8 w and 11.3 +/- 1.1 w x kg, whereas the mean PO across the 4 repeats was 647.1 +/- 96.3 w and 10.4 +/- 1.0 w x kg averaged for the 3 different tests. The fatigue index averaged 17.8 +/- 6.5%. The intraclass correlation coefficient for peak 5-second, mean PO, and fatigue index was 0.82, 0.86, and 0.82, respectively. This study reports the methodology of a repeated anaerobic power cycling test that was reliable for the measurement of PO and calculated fatigue index in varsity women ice hockey players and can be used as a laboratory-based assessment of repeated anaerobic fitness.

  12. Lesser Neural Pattern Similarity across Repeated Tests Is Associated with Better Long-Term Memory Retention.

    PubMed

    Karlsson Wirebring, Linnea; Wiklund-Hörnqvist, Carola; Eriksson, Johan; Andersson, Micael; Jonsson, Bert; Nyberg, Lars

    2015-07-01

    Encoding and retrieval processes enhance long-term memory performance. The efficiency of encoding processes has recently been linked to representational consistency: the reactivation of a representation that gets more specific each time an item is further studied. Here we examined the complementary hypothesis of whether the efficiency of retrieval processes also is linked to representational consistency. Alternatively, recurrent retrieval might foster representational variability--the altering or adding of underlying memory representations. Human participants studied 60 Swahili-Swedish word pairs before being scanned with fMRI the same day and 1 week later. On Day 1, participants were tested three times on each word pair, and on Day 7 each pair was tested once. A BOLD signal change in right superior parietal cortex was associated with subsequent memory on Day 1 and with successful long-term retention on Day 7. A representational similarity analysis in this parietal region revealed that beneficial recurrent retrieval was associated with representational variability, such that the pattern similarity on Day 1 was lower for retrieved words subsequently remembered compared with those subsequently forgotten. This was mirrored by a monotonically decreased BOLD signal change in dorsolateral prefrontal cortex on Day 1 as a function of repeated successful retrieval for words subsequently remembered, but not for words subsequently forgotten. This reduction in prefrontal response could reflect reduced demands on cognitive control. Collectively, the results offer novel insights into why memory retention benefits from repeated retrieval, and they suggest fundamental differences between repeated study and repeated testing. Repeated testing is known to produce superior long-term retention of the to-be-learned material compared with repeated encoding and other learning techniques, much because it fosters repeated memory retrieval. This study demonstrates that repeated memory

  13. PATCH image processor user's manual

    NASA Technical Reports Server (NTRS)

    Nieves, M. J. (Principal Investigator)

    1980-01-01

    The patch image processor extracts patches in various size (32 x 32, 64 x 64, 128 x 128, and 256 x 256 pixels) from full frame LANDSAT imagery data. With the patches that are extracted, a patch image mosaic is created in the image processing system, IMDACS, format.

  14. The Effects of Repeated Testing on Verbal and Nonverbal Ability Assessment.

    ERIC Educational Resources Information Center

    Lewis, Ernest L.; Beggs, Donald L.

    The purpose of this study was to attempt to determine if score gains obtained upon repeated testing with an intelligence test result from a practice effect, from students remembering specific items, or from a combination of both. The verbal and nonverbal batteries of an I.Q. test were administered to 860 sixth graders on three occasions with…

  15. Contrast of slightly complex patterns: computing the perceived contrast of Gabor patches

    NASA Astrophysics Data System (ADS)

    Peli, Eli

    1996-04-01

    The local contrast in an image may be approximated by the contrast of a Gabor patch of varying phase and bandwidth. In a search for a metric for such local contrast, perceived (apparent) contrast, as indicated by matching of such patterns, were compared here to the physical contrast calculated by a number of methods. The 2 cycles/deg 1-octave Gabor patch stimuli of different phases were presented side by side separated by 4 degrees. During each session the subjects (n equals 5) were adapted to the average luminance, and four different contrast levels (0.1, 0.3, 0.6, and 0.8) were randomly interleaved. The task was repeated at four mean luminance levels between 0.75 and 37.5 cd/m2. The subject's task was to indicate which of the two patterns was lower in contrast. Equal apparent contrast was determined by fitting a psychometric function to the data from 40 to 70 presentations. There was no effect of mean luminance on the subjects settings. The matching results rejected the hypothesis that either the Michelson formula or the King-Smith & Kulikowski contrast (CKK equals (Lmax-Laverage)/Laverage) was used by the subjects to set the match. The use of the Nominal contrast (the Michelson contrast of the underlying sinusoid) as an estimate of apparent contrast could not be rejected. In a second experiment the apparent contrast of a 1-octave Gabor patch was matched to the apparent contrast of a 2-octave Gabor patch (of Nominal contrast of 0.1, 0.3, 0.6, 0.8) using the method of adjustment. The result of this experiment rejected the prediction of the Nominal contrast definition. The local band limited contrast measure (Peli, 1990), when used with the modifications suggested by Lubin (1995), as an estimate of apparent contrast could not be rejected by the results of either experiment. These results suggest that a computational contrast measure based on multi scale bandpass filtering is a better estimate of apparent perceived contrast than any of the other measures tested.

  16. Monocular Patching May Induce Ipsilateral “Where” Spatial Bias

    PubMed Central

    Chen, Peii; Erdahl, Lillian; Barrett, Anna M.

    2009-01-01

    Spatial bias is an asymmetry of perception and/or representation of spatial information —“where” bias —, or of spatially directed actions — “aiming” bias. A monocular patch may induce contralateral “where” spatial bias (the Sprague effect; Sprague (1966) Science, 153, 1544–1547). However, an ipsilateral patch-induced spatial bias may be observed if visual occlusion results in top-down, compensatory re-allocation of spatial perceptual or representational resources toward the region of visual deprivation. Tactile distraction from a monocular patch may also contribute to an ipsilateral bias. To examine these hypotheses, neurologically normal adults bisected horizontal lines at baseline without a patch, while wearing a monocular patch, and while wearing tactile-only and visual-only monocular occlusion. We fractionated “where” and “aiming” spatial bias components using a video apparatus to reverse visual feedback for half of the test trials. The results support monocular patch-induced ipsilateral “where” spatial errors, which are not consistent with the Sprague effect. Further, the present findings suggested that the induced ipsilateral bias may be primarily induced by visual deprivation, consistent with compensatory “where” resource re-allocation. PMID:19100274

  17. Predictive Models of Cognitive Outcomes of Developmental Insults

    NASA Astrophysics Data System (ADS)

    Chan, Yupo; Bouaynaya, Nidhal; Chowdhury, Parimal; Leszczynska, Danuta; Patterson, Tucker A.; Tarasenko, Olga

    2010-04-01

    Representatives of Arkansas medical, research and educational institutions have gathered over the past four years to discuss the relationship between functional developmental perturbations and their neurological consequences. We wish to track the effect on the nervous system by developmental perturbations over time and across species. Except for perturbations, the sequence of events that occur during neural development was found to be remarkably conserved across mammalian species. The tracking includes consequences on anatomical regions and behavioral changes. The ultimate goal is to develop a predictive model of long-term genotypic and phenotypic outcomes that includes developmental insults. Such a model can subsequently be fostered into an educated intervention for therapeutic purposes. Several datasets were identified to test plausible hypotheses, ranging from evoked potential datasets to sleep-disorder datasets. An initial model may be mathematical and conceptual. However, we expect to see rapid progress as large-scale gene expression studies in the mammalian brain permit genome-wide searches to discover genes that are uniquely expressed in brain circuits and regions. These genes ultimately control behavior. By using a validated model we endeavor to make useful predictions.

  18. Estradiol Transdermal Patch

    MedlinePlus

    Most brands of estradiol transdermal patches are used to treat hot flushes (hot flashes; sudden strong feelings of heat ... different medication that does not contain estrogen. Most brands of estradiol transdermal patches are also sometimes used ...

  19. Ethinyl Estradiol and Norelgestromin Transdermal Patch

    MedlinePlus

    ... the skin. One patch is applied once a week for 3 weeks, followed by a patch-free week. Follow the directions on your prescription label carefully, ... new patch on the same day of the week (the Patch Change Day). Apply a new patch ...

  20. Scale-dependent feedbacks between patch size and plant reproduction in desert grassland

    USGS Publications Warehouse

    Svejcar, Lauren N.; Bestelmeyer, Brandon T.; Duniway, Michael C.; James, Darren K.

    2015-01-01

    Theoretical models suggest that scale-dependent feedbacks between plant reproductive success and plant patch size govern transitions from highly to sparsely vegetated states in drylands, yet there is scant empirical evidence for these mechanisms. Scale-dependent feedback models suggest that an optimal patch size exists for growth and reproduction of plants and that a threshold patch organization exists below which positive feedbacks between vegetation and resources can break down, leading to critical transitions. We examined the relationship between patch size and plant reproduction using an experiment in a Chihuahuan Desert grassland. We tested the hypothesis that reproductive effort and success of a dominant grass (Bouteloua eriopoda) would vary predictably with patch size. We found that focal plants in medium-sized patches featured higher rates of grass reproductive success than when plants occupied either large patch interiors or small patches. These patterns support the existence of scale-dependent feedbacks in Chihuahuan Desert grasslands and indicate an optimal patch size for reproductive effort and success in B. eriopoda. We discuss the implications of these results for detecting ecological thresholds in desert grasslands.

  1. A method to visualize transdermal nickel permeation in mouse skin using a nickel allergy patch

    PubMed Central

    Sugiyama, Tomoko; Uo, Motohiro; Wada, Takahiro; Hongo, Toshio; Omagari, Daisuke; Komiyama, Kazuo; Oikawa, Masakazu; Kusama, Mikio; Mori, Yoshiyuki

    2015-01-01

    Metal patch test is often used in clinical settings when metal-induced contact dermatitis is suspected. However, the transdermal permeation behavior of metal ions from the patch test remains unclear. Current patch tests using high concentrations of metal salt solutions have some side effects, e.g. acute skin reactions to high concentrations of metal salt. To resolve these, estimating metal ion transdermal permeation is wished. In this study, synchrotron radiation X-ray fluorescence (SR-XRF) and micro-focused particle-induced X-ray emission (micro-PIXE) were used to visualize the time-dependent Ni permeation in mouse skin. The cross-sectional diffusion of Ni was visualized in a time-dependent manner. Our results indicate that maximum Ni permeation occurs after 24 h of patch treatment, and the permeated Ni content was high in the epidermis and spread into the dermis beyond the basal layer. This method may be useful to determine the appropriate solution concentration and duration of administration for the patch test. PMID:26484550

  2. GENDER-SPECIFIC DIFFERENCES IN THE RESPONSE OF MATURING GAMETES TO TOXIC INSULT

    EPA Science Inventory

    GENDER-SPECIFIC DIFFERENCES IN THE RESPONSE OF MATURING GAMETES TO TOXIC INSULT

    Sally D. Perreault, U. S. Environmental Toxicology Division, National Health and Environmental Effects Research Laboratory, Reproductive Toxicology Division, Research Triangle Park, NC 27711

  3. Foraging decisions, patch use, and seasonality in egrets (Aves: ciconiiformes)

    USGS Publications Warehouse

    Erwin, R.M.

    1985-01-01

    Feeding snowy (Egretta thula) and great (Casmerodius albus) egrets were observed during 2 breeding seasons in coastal New Jersey and 2 brief winter periods in northeast Florida (USA). A number of tests based on assumptions of foraging models, predictions from foraging theory, and earlier empirical tests concerning time allocation and movement in foraging patches was made. Few of the expectations based on foraging theory and/or assumptions were supported by the empirical evidence. Snowy egrets fed with greater intensity and efficiency during the breeding season (when young were being fed) than during winter. They also showed some tendency to leave patches when their capture rate declined, and they spent more time foraging in patches when other birds were present nearby. Great egrets showed few of these tendencies, although they did leave patches when their intercapture intervals increased. Satiation differences had some influence on feeding rates in snowy egrets, but only at the end of feeding bouts. Some individuals of both species revisited areas in patches that had recently been exploited, and success rates were usually higher after the 2nd visit. Apparently, for predators of active prey, short-term changes in resource availability ('resource depression') may be more important than resource depletion, a common assumption in most optimal foraging theory models.

  4. Repeatability and responsiveness of exercise tests in pulmonary arterial hypertension.

    PubMed

    Mainguy, Vincent; Malenfant, Simon; Neyron, Anne-Sophie; Bonnet, Sébastien; Maltais, François; Saey, Didier; Provencher, Steeve

    2013-08-01

    Exercise tolerance in pulmonary arterial hypertension (PAH) is most commonly assessed by the 6-min walk test (6MWT). Whether endurance exercise tests are more responsive than the 6MWT remains unknown. 20 stable PAH patients (mean±sd age 53±15 years and mean pulmonary arterial pressure 44±16 mmHg) already on PAH monotherapy completed the 6MWT, the endurance shuttle walk test (ESWT) and the cycle endurance test (CET) before and after the addition of sildenafil citrate 20 mg three times daily or placebo for 28 days in a randomised double-blind crossover setting. Pre- or post-placebo tests were used to assess repeatability of each exercise test, whereas pre- or post-sildenafil citrate tests were used to assess their responsiveness. Sildenafil citrate led to placebo-corrected changes in exercise capacity of 18±25 m (p = 0.02), 58±235 s (p = 0.58) and 29±77 s (p = 0.09) for the 6MWT, the ESWT and the CET, respectively. The 6MWT was associated with a lower coefficient of variation between repeated measures (3% versus 18% versus 13%), resulting in a higher standardised response mean compared with endurance tests (0.72, 0.25 and 0.38 for the 6MWT, the ESWT and the CET, respectively). The 6MWT had the best ability to capture changes in exercise capacity when sildenafil citrate was combined with patients' baseline monotherapy, supporting its use as an outcome measure in PAH.

  5. Sperm Patch-Clamp

    PubMed Central

    Lishko, Polina; Clapham, David E.; Navarro, Betsy; Kirichok, Yuriy

    2014-01-01

    Sperm intracellular pH and calcium concentration ([Ca2+]i) are two central factors that control sperm activity within the female reproductive tract. As such, the ion channels of the sperm plasma membrane that alter intracellular sperm [Ca2+] and pH play important roles in sperm physiology and the process of fertilization. Indeed, sperm ion channels regulate sperm motility, control sperm chemotaxis toward the egg in some species, and may trigger the acrosome reaction. Until recently, our understanding of these important molecules was rudimentary due to the inability to patch-clamp spermatozoa and directly record the activity of these ion channels under voltage clamp. Recently, we overcame this technical barrier and developed a method for reproducible application of the patch-clamp technique to mouse and human spermatozoa. This chapter covers important aspects of application of the patch-clamp technique to spermatozoa, such as selection of the electrophysiological equipment, isolation of spermatozoa for patch-clamp experiments, formation of the gigaohm seal with spermatozoa, and transition into the whole-cell mode of recording. We also discuss potential pitfalls in application of the patch-clamp technique to flagellar ion channels. PMID:23522465

  6. Contact allergy to essential oils: current patch test results (2000-2008) from the Information Network of Departments of Dermatology (IVDK).

    PubMed

    Uter, Wolfgang; Schmidt, Erich; Geier, Johannes; Lessmann, Holger; Schnuch, Axel; Frosch, Peter

    2010-11-01

    Essential oils are used in perfumery and in products for aromatherapy or balneotherapy. Previous studies have shown some to be important contact sensitizers. A practical diagnostic approach, based on the results of a large, central European network and other evidence, is needed. Data of the Information Network of Departments of Dermatology (IVDK; www.ivdk.org) on all patients patch tested between January 2000 and December 2008 with essential oils were retrospectively analysed. 15 682 patients of 84 716 consulting in the period had been tested with at least one essential oil, and 637 reacted positively to at least one of the essential oils, most commonly to ylang-ylang oil (I and II) (3.1% as weighted mean of positive tests in special series and consecutive testing), lemongrass oil (1.8%), jasmine absolute (1.6%), sandalwood oil and clove oil (1.5% each). Cross-reactivity between distillate and main allergen, if available, was marked. Patch testing the important essential oils should be considered in patients with a suggestive history. Additionally, culprit products brought in by the patient should be tested, closing a diagnostic gap by (i) including those other essential oils not included in the commercial test series and (ii) providing a means of testing with the oxidized substances to which the patient had actually been exposed. © 2010 John Wiley & Sons A/S.

  7. PlenoPatch: Patch-Based Plenoptic Image Manipulation.

    PubMed

    Zhang, Fang-Lue; Wang, Jue; Shechtman, Eli; Zhou, Zi-Ye; Shi, Jia-Xin; Hu, Shi-Min

    2017-05-01

    Patch-based image synthesis methods have been successfully applied for various editing tasks on still images, videos and stereo pairs. In this work we extend patch-based synthesis to plenoptic images captured by consumer-level lenselet-based devices for interactive, efficient light field editing. In our method the light field is represented as a set of images captured from different viewpoints. We decompose the central view into different depth layers, and present it to the user for specifying the editing goals. Given an editing task, our method performs patch-based image synthesis on all affected layers of the central view, and then propagates the edits to all other views. Interaction is done through a conventional 2D image editing user interface that is familiar to novice users. Our method correctly handles object boundary occlusion with semi-transparency, thus can generate more realistic results than previous methods. We demonstrate compelling results on a wide range of applications such as hole-filling, object reshuffling and resizing, changing object depth, light field upscaling and parallax magnification.

  8. Taro corms mucilage/HPMC based transdermal patch: an efficient device for delivery of diltiazem hydrochloride.

    PubMed

    Sarkar, Gunjan; Saha, Nayan Ranjan; Roy, Indranil; Bhattacharyya, Amartya; Bose, Madhura; Mishra, Roshnara; Rana, Dipak; Bhattacharjee, Debashis; Chattopadhyay, Dipankar

    2014-05-01

    The aim of this work is to examine the effectiveness of mucilage/hydroxypropylmethylcellulose (HPMC) based transdermal patch (matrix type) as a drug delivery device. We have successfully extracted mucilage from Colocasia esculenta (Taro) corms and prepared diltiazem hydrochloride incorporated mucilage/HPMC based transdermal patches using various wt% of mucilage by the solvent evaporation technique. Characterization of both mucilage and transdermal patches has been done by several techniques such as Molisch's test, organoleptic evaluation of mucilage, mechanical, morphological and thermal analysis of transdermal patches. Skin irritation test is studied on hairless Albino rat skin showing that transdermal patches are apparently free of potentially hazardous skin irritation. Fourier transform infrared analysis shows that there is no interaction between drug, mucilage and HPMC while scanning electron microscopy shows the surface morphology of transdermal patches. In vitro drug release time of mucilage-HPMC based transdermal patches is prolonged with increasing mucilage concentration in the formulation. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Positive patch test reactions to oxidized limonene: exposure and relevance.

    PubMed

    Bråred Christensson, Johanna; Andersen, Klaus E; Bruze, Magnus; Johansen, Jeanne D; Garcia-Bravo, Begoña; Gimenez Arnau, Ana; Goh, Chee-Leok; Nixon, Rosemary; White, Ian R

    2014-11-01

    R-Limonene is a common fragrance terpene found in domestic and industrial products. R-Limonene autoxidizes on air exposure, and the oxidation products can cause contact allergy. In a recent multicentre study, 5.2% (range 2.3-12.1%) of 2900 patients showed a positive patch test reaction to oxidized R-limonene. To study the exposure to limonene among consecutive dermatitis patients reacting to oxidized R-limonene in an international setting, and to assess the relevance of the exposure for the patients' dermatitis. Oxidized R-limonene 3.0% (containing limonene hydroperoxides at 0.33%) in petrolatum was tested in 2900 consecutive dermatitis patients in Australia, Denmark, the United Kingdom, Singapore, Spain, and Sweden. A questionnaire assessing exposure to limonene-containing products was completed. Overall, exposure to products containing limonene was found and assessed as being probably relevant for the patients' dermatitis in 36% of the limonene-allergic patients. In Barcelona and Copenhagen, > 70% of the patients were judged to have had an exposure to limonene assessed as relevant. Oxidized R-limonene is a common fragrance allergen, and limonene was frequently found in the labelling on the patients' products, and assessed as relevant for the patients' dermatitis. A large number of domestic and occupational sources for contact with R-limonene were identified. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Test-Retest Repeatability of Myocardial Blood Flow Measurements using Rubidium-82 Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Efseaff, Matthew

    Rubidium-82 positron emission tomography (PET) imaging has been proposed for routine myocardial blood flow (MBF) quantification. Few studies have investigated the test-retest repeatability of this method. Same-day repeatability of rest MBF imaging was optimized with a highly automated analysis program using image-derived input functions and a dual spillover correction (SOC). The effects of heterogeneous tracer infusion profiles and subject hemodynamics on test-retest repeatability were investigated at rest and during hyperemic stress. Factors affecting rest MBF repeatability included gender, suspected coronary artery disease, and dual SOC (p < 0.001). The best repeatability coefficient for same-day rest MBF was 0.20 mL/min/g using a six-minute scan-time, iterative reconstruction, dual SOC, resting rate-pressure-product (RPP) adjustment, and a left atrium image-derived input function. The serial study repeatabilities of the optimized protocol in subjects with homogeneous RPPs and tracer infusion profiles was 0.19 and 0.53 mL/min/g at rest and stress, and 0.95 for stress / rest myocardial flow reserve (MFR). Subjects with heterogeneous tracer infusion profiles and hemodynamic conditions had significantly less repeatable MBF measurements at rest, stress, and stress/rest flow reserve (p < 0.05).

  11. Randomized, double-blind, placebo-controlled trial using lidocaine patch 5% in traumatic rib fractures.

    PubMed

    Ingalls, Nichole K; Horton, Zachary A; Bettendorf, Matthew; Frye, Ira; Rodriguez, Carlos

    2010-02-01

    The lidocaine patch 5% was developed to treat postherpetic neuralgia. Anecdotal experience at our institution suggests the lidocaine patch 5% decreases narcotic usage in patients with traumatic rib fractures. This trial was developed to define the patch's efficacy. Patients with rib fractures admitted to the trauma service at our Level I trauma center were enrolled and randomized in a 1 to 1 double-blind manner to receive a lidocaine patch 5% or placebo patch. Fifty-eight patients who met the inclusion criteria were enrolled from January 2007 to August 2008. Demographic and clinical information were recorded. The primary outcomes variable was total narcotic use, analyzed using the 1-tailed Mann-Whitney test. The secondary outcomes variables included non-narcotic pain medication, average pain score, pulmonary complications, and length of stay. Significance was defined based on a 1-sided test for the primary outcome and 2-sided tests for other comparisons, at p < 0.05. Thirty-three patients received the lidocaine patch 5% and 25 received the placebo patch. There were no significant differences in age, number of rib fractures, gender, trauma mechanism, preinjury lung disease, smoking history, percent of current smokers, and need for placement of chest tube between the lidocaine patch 5% and placebo groups. There was no difference between the lidocaine patch 5% and placebo groups, respectively, with regard to total IV narcotic usage: median, 0.23 units versus 0.26 units; total oral narcotics: median, 4 units versus 7 units; pain score: 5.6 +/- 0.4 versus 6.0 +/- 0.3 (mean +/- SEM); length of stay: 7.8 +/- 1.1 versus 6.2 +/- 0.7; or percentage of patients with pulmonary complications: 72.7% versus 72.0%. The lidocaine patch 5% does not significantly improve pain control in polytrauma patients with traumatic rib fractures.

  12. Patch testing with serial dilutions and thin-layer chromatograms of oak moss absolutes containing high and low levels of atranol and chloroatranol.

    PubMed

    Mowitz, Martin; Zimerson, Erik; Svedman, Cecilia; Bruze, Magnus

    2013-12-01

    Oak moss absolute (Evernia prunastri extract) contains a large number of substances, among them the potent allergens atranol and chloroatranol. Since 2008, their content in oak moss absolute has been restricted by the International Fragrance Association to a maximum level of 100 ppm each. To compare the elicitation capacities of a traditional (sample A) and a treated (sample B) oak moss absolute containing, in total, 27 000 and 66 ppm of atranol and chloroatranol, respectively, and to investigate reactions to components of oak moss absolute separated by thin-layer chromatography (TLC). Fifteen oak moss-allergic subjects were patch tested with serial dilutions and TLC strips of samples A and B. Fifteen subjects reacted to sample A at concentrations ≤ 2.0%, and 2 subjects reacted to sample B at 2.0% but not to lower concentrations. Among 13 subjects reacting to the TLC strip of sample A, 11 reacted to spots with retardation factor values corresponding to those of atranol and/or chloroatranol, and 11 reacted to other areas on the TLC strip. Only one subject reacted to the TLC strip of sample B. The patch test reactivity of sample B was significantly lower than that of sample A. The TLC patch tests indicate the presence of sensitizers other than atranol and chloroatranol in oak moss absolute. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Improved Gain Microstrip Patch Antenna

    DTIC Science & Technology

    2015-08-06

    08-2015 Publication Improved Gain Microstrip Patch Antenna David A. Tonn Naval Under Warfare Center Division, Newport 1176 Howell St., Code 00L...GAIN MICROSTRIP PATCH ANTENNA STATEMENT OF GOVERNMENT INTEREST [0001] The invention described herein may be manufactured and used by or for the...patch antenna having increased gain, and an apparatus for increasing the gain and bandwidth of an existing microstrip patch antenna . (2) Description

  14. Strategies to Improve Repeat Fecal Occult Blood Testing Cancer Screening

    PubMed Central

    Davis, Terry C.; Arnold, Connie L.; Bennett, Charles L.; Wolf, Michael S.; Reynolds, Cristalyn; Liu, Dachao; Rademaker, Alfred

    2013-01-01

    Background A comparative effectiveness intervention by this team improved initial fecal occult blood testing (FOBT) rates from 3% to 53% among community clinic patients. The purpose of this study was to evaluate the effectiveness and costs associated with a literacy-informed intervention on repeat FOBT testing. Methods Between 2008 and 2011, a three-arm quasi-experiential comparative effectiveness evaluation was conducted in 8 community clinics in Louisiana. Clinics were randomly assigned to receive: enhanced care, a screening recommendation and FOBT kit annually; a brief educational intervention where patients additionally received a literacy appropriate pamphlet and simplified FOBT instructions; or nurse support where a nurse manager provided the education and followed up with phone support. In year 2 all materials were mailed. The study consisted of 461 patients, ages 50–85, with a negative initial FOBT. Results Repeat FOBT rates were 38% enhanced care, 33% education, and 59% with nurse support (p=0.017). After adjusting for age, race, gender, and literacy, patients receiving nurse support were 1.46 times more likely to complete repeat FOBT screening than those receiving education (95% CI 1.14–1.06, p=0.002) and 1.45 times more likely than those in enhanced care but this was not significant (95% CI 0.93–2.26 p=0.10). The incremental cost per additional person screened was $2,450 for nurse over enhanced care. Conclusion A mailed pamphlet and FOBT with simplified instructions did not improve annual screening. Impact Telephone outreach by a nurse manager was effective in improving rates of repeat FOBT yet this may be too costly for community clinics. PMID:24192009

  15. Cementitious materials for thin patches : final report.

    DOT National Transportation Integrated Search

    2001-06-01

    Ten cementitious patching materials, which were suitable for thin, vertical repairs according to the manufacturers, were evaluated. Compatibility with cathodic protection systems was a particular concern. The materials were tested for propensity to c...

  16. Constituents of smoke from cigarettes made from diverted nicotine replacement therapy patches.

    PubMed

    Morrissey, Hana; Ball, Patrick; Boland, Martin; Hefler, Marita; Thomas, David P

    2016-03-01

    Anecdotes of nicotine replacement therapy patch misuse associated with the introduction of smoke-free prisons have been reported by media internationally, including Canada in 2006, New Zealand in 2011 and Australia in 2014. This study identifies chemical compounds released through diverted nicotine replacement therapy patches when they are smoked. Two samples were produced: (i) shredded 21 mg nicotine replacement therapy patches rolled with tea leaves into a cigarette; and (ii) patches boiled in water and tea leaves, and then dried tea leaves rolled into a cigarette. The smoke was tested for nicotine, caffeine and toxins. High-performance liquid chromatography, mass spectrometry and spectrophotometry were used to detect the presence and quantity of nicotine and caffeine. A specialised laboratory was contracted to test the presence of toxins. Nicotine was liberated when the two samples were burnt but not if the nicotine replacement therapy patches were boiled in water alone. High concentrations of formaldehyde, acetaldehyde, acrolein, toluene, xylene and heavy metals were also released. Nicotine is released when diverted nicotine replacement therapy patches are smoked, as are caffeine and harmful toxins. These toxins have the potential to cause short- and long-term health damage. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  17. Cardiopulmonary exercise testing early after stroke using feedback-controlled robotics-assisted treadmill exercise: test-retest reliability and repeatability.

    PubMed

    Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J

    2014-10-11

    Exercise capacity is seriously reduced after stroke. While cardiopulmonary assessment and intervention strategies have been validated for the mildly and moderately impaired populations post-stroke, there is a lack of effective concepts for stroke survivors suffering from severe motor limitations. This study investigated the test-retest reliability and repeatability of cardiopulmonary exercise testing (CPET) using feedback-controlled robotics-assisted treadmill exercise (FC-RATE) in severely motor impaired individuals early after stroke. 20 subjects (age 44-84 years, <6 month post-stroke) with severe motor limitations (Functional Ambulatory Classification 0-2) were selected for consecutive constant load testing (CLT) and incremental exercise testing (IET) within a powered exoskeleton, synchronised with a treadmill and a body weight support system. A manual human-in-the-loop feedback system was used to guide individual work rate levels. Outcome variables focussed on standard cardiopulmonary performance parameters. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean difference, limits of agreement, and coefficient of variation (CoV) were estimated to assess repeatability. Peak performance parameters during IET yielded good to excellent relative reliability: absolute peak oxygen uptake (ICC =0.82), relative peak oxygen uptake (ICC =0.72), peak work rate (ICC =0.91), peak heart rate (ICC =0.80), absolute gas exchange threshold (ICC =0.91), relative gas exchange threshold (ICC =0.88), oxygen cost of work (ICC =0.87), oxygen pulse at peak oxygen uptake (ICC =0.92), ventilation rate versus carbon dioxide output slope (ICC =0.78). For these variables, SEM was 4-13%, MDC 12-36%, and CoV 0.10-0.36. CLT revealed high mean differences and insufficient test-retest reliability for all variables studied. This study presents

  18. Development of a REBCO HTS magnet for Maglev - repeated bending tests of HTS pancake coils -

    NASA Astrophysics Data System (ADS)

    Sugino, Motohikoa; Mizuno, Katsutoshi; Tanaka, Minoru; Ogata, Masafumi

    2018-01-01

    In the past study, two manufacturing methods were developed that can manufacture pancake coils by using REBCO coated conductors. It was confirmed that the conductors have no electric degradation that caused by the manufacturing method. The durability evaluation tests of the pancake coils were conducted as the final evaluation of the coil manufacturing method in this study. The repeated bending deformation was applied to manufactured pancake coils in the tests. As the results of these tests, it was confirmed that the pancake coils that were manufactured by two methods had the durability for the repeated bending deformation and the coils maintained the appropriate mechanical performance and electric performance. We adopted the fusion bonding method as the coil manufacturing method of the HTS magnet Furthermore, using the prototype pancake coil that was manufactured by the fusion bonding method as a test sample, the repeated bending test under the exited condition was conducted. Thus it was confirmed that the coil manufactured by the fusion bonding method has no degradation of the electricity performance and the mechanical properties even if the repeated bending deformation was applied under the exited condition.

  19. Examining Repeaters' Performance on Second Language Proficiency Tests: A Review and a Call for Research

    ERIC Educational Resources Information Center

    Barkaoui, Khaled

    2017-01-01

    As the number of candidates who repeat English language proficiency tests more than once to meet a certain cutscore (e.g., for university admission) or to demonstrate progress (e.g., after instruction) continues to increase dramatically, there is a need for more research on the attributes and test performance of test repeaters. This article…

  20. Oracle Applications Patch Administration Tool (PAT) Beta Version

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2002-01-04

    PAT is a Patch Administration Tool that provides analysis, tracking, and management of Oracle Application patches. This includes capabilities as outlined below: Patch Analysis & Management Tool Outline of capabilities: Administration Patch Data Maintenance -- track Oracle Application patches applied to what database instance & machine Patch Analysis capture text files (readme.txt and driver files) form comparison detail report comparison detail PL/SQL package comparison detail SQL scripts detail JSP module comparison detail Parse and load the current applptch.txt (10.7) or load patch data from Oracle Application database patch tables (11i) Display Analysis -- Compare patch to be applied with currentmore » Oracle Application installed Appl_top code versions Patch Detail Module comparison detail Analyze and display one Oracle Application module patch. Patch Management -- automatic queue and execution of patches Administration Parameter maintenance -- setting for directory structure of Oracle Application appl_top Validation data maintenance -- machine names and instances to patch Operation Patch Data Maintenance Schedule a patch (queue for later execution) Run a patch (queue for immediate execution) Review the patch logs Patch Management Reports« less

  1. Resource concentration hypothesis: effect of host plant patch size on density of herbivorous insects.

    PubMed

    Grez, A A; González, R H

    1995-09-01

    The resource concentration hypothesis (Root 1973) predicts that specialist herbivorous insects should be more abundant in large patches of host plants, because the insects are more likely to find and stay longer in those patches. Between August 1989 and January 1990 we experimentally tested Root's hypothesis by analyzing the numerical response of four species of herbivorous insects associated with patches of 4, 16, 64 and 225 cabbage plants, Brassica oleracea var. capitata. In addition, we studied the colonization of patches by adults of Plutella xylostella (L.) (Lepidoptera: Plutellidae), and the migration of their larvae in patches of different sizes. No herbivorous insect densities differed significantly with patch size. Adults of P. xylostella colonized all kind of patches equally. Larvae did not migrate between patches, and their disappearance rate did not differ between patches. The resource concentration hypothesis is organism-dependent, being a function of the adult and juvenile herbivore dispersal behavior in relation to the spatial scale of patchiness.

  2. Experimental Fatigue Study of Composite Patch Repaired Steel Plates with Cracks

    NASA Astrophysics Data System (ADS)

    Karatzas, Vasileios A.; Kotsidis, Elias A.; Tsouvalis, Nicholas G.

    2015-10-01

    Cracks are among the most commonly encountered defects in metallic structures operating at sea. Composite patch repairing is a repair method which is gaining popularity as it counters most of the problems faced by conventional renewal repairs. Extensive studies can be found in the literature addressing the efficiency of this novel repair method using techniques which meet higher performance and monitoring standards than these commonly found in naval applications. In this work the efficiency of practices widely used in the ship repair industry for the implementation of composite patch repairing is addressed. To this end, steel plates repaired with composite patches were tested under fatigue loading. The composite patches consisted of carbon fibers in epoxy matrix and were directly laminated to the steel surface using the vacuum infusion method. Two different surface preparation methods, namely grit-blasting and mechanical treatment with the use of a needle gun were studied. In addition, in order to account for the harsh environmental conditions during the operating life of the structure and to study its effect on the repair, two different aging scenarios were considered. Non-destructive evaluation of the patches was performed so as to assess the quality of the repair, and the evolution of debonding during testing.

  3. Departure Mechanisms for Host Search on High-Density Patches by the Meteorus pulchricornis

    PubMed Central

    Sheng, Sheng; Feng, Sufang; Meng, Ling; Li, Baoping

    2014-01-01

    Abstract Less attention has been paid to the parasitoid–host system in which the host occurs in considerably high density with a hierarchical patch structure in studies on time allocation strategies of parasitoids. This study used the parasitoid Meteorus pulchricornis (Wesmael) (Hymenoptera: Braconidae) and the Oriental leafworm, Spodoptera litura (Fabricius) (Lepidoptera: Noctuidae) as the parasitoids–host model system to investigate patch-leaving mechanisms as affected by the high-host density, hierarchical patch structure, and foraging behaviors on both former and current patches. The results showed that three out of eight covariates tested had significant effects on the patch-leaving tendency, including the host density, ovipositor insertion, and host rejection on the current patch. The parasitoid paid more visits to the patch with high-density hosts. While the patch with higher host densities decreased the leaving tendency, the spatial distribution of hosts examined had no effect on the leaving tendency. Both oviposition and host rejection decreased the patch-leaving tendency. The variables associated with the former patch, such as the host density and number of ovipositor insertions, however, did not have an effect on the leaving tendency. Our study suggested that M. pulchricornis females may use an incremental mechanism to exploit high-density patches to the fullest. PMID:25502040

  4. Neuroprotective Effects of Cannabidiol in Hypoxic Ischemic Insult. The Therapeutic Window in Newborn Mice.

    PubMed

    Mohammed, Nagat; Ceprian, Maria; Jimenez, Laura; Pazos, M Ruth; Martínez-Orgado, Jose

    2017-01-01

    A relevant therapeutic time window (TTW) is an important criterion for considering the clinical relevance of a substance preventing newborn hypoxic-ischemic (HI) brain damage. To test the TTW of the neuroprotective effects of cannabidol (CBD), a non-psychoactive cannabinoid in a model of newborn HI brain damage. 9-10 day-old C57BL6 mice underwent a HI insult (10% oxygen for 90 min after left carotid artery electrocoagulation). Then, CBD 1 mg/kg or vehicle were administered s.c. 15 min, or 1, 3, 6, 12, 18 or 24 h after the end of the HI insult. Seven days later brain damage was assessed using T2W Magnetic Resonance Imaging scan (ipsilateral hemisphere volume loss, IVHL) and histological studies: Nissl staining (neuropathological score), TUNEL staining (apoptotic damage) and immunohistochemistry with glial fibrillary acidic protein (astrocyte viability) or ionized calcium binding adaptor molecule (microglial activation). CBD administered up to 18 h after HI reduced IHVL and neuropathological score by 60%, TUNEL+ count by 90% and astrocyte damage by 50%. In addition, CBD blunted the HI-induced increase in microglial population. When CBD administration was delayed 24 h, however, the neuroprotective effect was lost in terms of IHVL, apoptosis or astrogliosis reduction. CBD shows a TTW of 18 h when administered to HI newborn mice, which represents a broader TTW than reported for other neuroprotective treatments including hypothermia. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Food-Related Contact Dermatitis, Contact Urticaria, and Atopy Patch Test with Food.

    PubMed

    Walter, Alexandra; Seegräber, Marlene; Wollenberg, Andreas

    2018-06-07

    A wide variety of foods may cause or aggravate skin diseases such as contact dermatitis, contact urticaria, or atopic dermatitis (AD), both in occupational and private settings. The mechanism of action underlying allergic disease to food, food additives, and spices may be immunologic and non-immunologic. The classification and understanding of these reactions is a complex field, and knowledge of the possible reaction patterns and appropriate diagnostic test methods is essential. In addition, certain foods may cause worsening of atopic dermatitis lesions in children. The atopy patch test (APT) is a well-established, clinically useful tool for assessing delayed type reactions to protein allergens in patients and may be useful to detect protein allergens relevant for certain skin diseases. The APT may even detect sensitization against allergens in intrinsic atopic dermatitis patients, who show negative skin prick test and negative in vitro IgE test results against these allergens. Native foods, SPT solutions on filter paper, and purified allergens in petrolatum have been used for APT. The European Task Force on Atopic Dermatitis (ETFAD) has worked on standardizing this test in the context of AD patients, who are allergic to aeroallergens and food. This recommended, standardized technique involves test application at the upper back of children and adults; use of large, 12-mm Finn chambers; avoidance of any pre-treatment such as tape stripping or delipidation; standardized amounts of purified allergens in petrolatum; and use of the standardized ETFAD reading key. The APT may not be the best working or best standardized of all possible skin tests, but it is the best test that we currently have available in this niche.

  6. Spin Glass Patch Planting

    NASA Technical Reports Server (NTRS)

    Wang, Wenlong; Mandra, Salvatore; Katzgraber, Helmut G.

    2016-01-01

    In this paper, we propose a patch planting method for creating arbitrarily large spin glass instances with known ground states. The scaling of the computational complexity of these instances with various block numbers and sizes is investigated and compared with random instances using population annealing Monte Carlo and the quantum annealing DW2X machine. The method can be useful for benchmarking tests for future generation quantum annealing machines, classical and quantum mechanical optimization algorithms.

  7. Diagnostic performance of the atopy patch test with inhalant allergens.

    PubMed

    Fuiano, N; Diddi, G; Delvecchio, M; Incorvaia, C

    2015-01-01

    This study evaluated the diagnostic performance of the atopy patch test (APT) compared with skin prick testing (SPT) and in vitro IgE measurement in a large group of patients with atopic dermatitis (AD) with or without respiratory symptoms (RS). The study included 521 patients (292 males, 229 females; age, 0.5-18 years; median age, 6 years) with AD and RS with different clinical presentations: current AD, 47 patients (Group A); current AD and RS, 72 patients (Group B), past AD and RS, 69 patients (Group C); and RS only, 280 patients (Group D). Fifty-three healthy individuals served as controls. All participants underwent the APT, SPT, and CAP/RAST with the most common inhalant allergens. The presence of a control group allowed calculation of specificity and positive and negative predictive values. A significant difference was found for a positive APT versus both SPT and CAP/RAST (P < .0001) but not for SPT versus CAP/RAST. The differences for APT were significant in all group comparisons except group B vs C and group C vs D. In the control group, the APT was positive in 2% of cases (specificity of 96.2%), SPT was positive in 6% of cases (specificity of 88.4%), and CAP/RAST was positive in 4% of cases (specificity of 92.5%). In young patients sensitized to inhalant allergens with AD in addition to RS, the APT has a superior diagnostic performance to SPT and in vitro IgE measurement.

  8. Single-layer dual frequency patch antenna

    NASA Astrophysics Data System (ADS)

    Maci, S.; Gentili, G. B.; Avitabile, G.

    1993-08-01

    A configuration for a slotted patch antenna is introduced which allows two separate operating frequencies. Both of these frequencies are associated with a radiating mode almost identical to that of a standard patch. The two resonances are related to the patch width and the slot/patch length, respectively.

  9. The effect of habitat patch size on small mammal populations

    Treesearch

    Mark D. Yates; Susan C. Loeb; David C. Guynn

    1997-01-01

    Habitat fragmentation is one of the greatest threats to the conservation of bio­diversity and has 3 components: habitat loss, patch isolation, and patch size. The authors tested the effects of forest-clearing size on small mammal populations in the Upper Coastal Plain of South Carolina. These clearings act as islands for many species of small mam­mals, particularly old...

  10. A study of tensile residual strength of composite laminates under different patch-repaired series

    NASA Astrophysics Data System (ADS)

    Ding, M. H.; zhan, S.; Tang, Y. H.; Wang, L.; Ma, D. Q.; Wang, R. G.

    2017-09-01

    The tensile behavior of composite laminate structures repaired by bonding external patches was studied in the paper. Two different types of patches including wedge patches and inverted wedge patches were used and failure mechanisms, failure load and strength predictions were studied. A convenient and fast method of building 2-D finite element modeling (FEM) of laminate structure repaired was proposed and the strength of repaired laminate structures was calculated by FEM. The results showed that more than 80% tensile strength of the undamaged laminate could be recovered by bonding patch repairs. Moreover, the results indicated that the strength of inverted wedge patches repair were higher than that of wedge patches repair. FEM simulation results indicated that high stress concentration was found along the edges of invert patches and the most weakness part located in the adhesive bondline. FEM analysis results showed that the strength predicted matched well with the test strength.

  11. Patch Finder Plus (PFplus): a web server for extracting and displaying positive electrostatic patches on protein surfaces.

    PubMed

    Shazman, Shula; Celniker, Gershon; Haber, Omer; Glaser, Fabian; Mandel-Gutfreund, Yael

    2007-07-01

    Positively charged electrostatic patches on protein surfaces are usually indicative of nucleic acid binding interfaces. Interestingly, many proteins which are not involved in nucleic acid binding possess large positive patches on their surface as well. In some cases, the positive patches on the protein are related to other functional properties of the protein family. PatchFinderPlus (PFplus) http://pfp.technion.ac.il is a web-based tool for extracting and displaying continuous electrostatic positive patches on protein surfaces. The input required for PFplus is either a four letter PDB code or a protein coordinate file in PDB format, provided by the user. PFplus computes the continuum electrostatics potential and extracts the largest positive patch for each protein chain in the PDB file. The server provides an output file in PDB format including a list of the patch residues. In addition, the largest positive patch is displayed on the server by a graphical viewer (Jmol), using a simple color coding.

  12. Patch Finder Plus (PFplus): A web server for extracting and displaying positive electrostatic patches on protein surfaces

    PubMed Central

    Shazman, Shula; Celniker, Gershon; Haber, Omer; Glaser, Fabian; Mandel-Gutfreund, Yael

    2007-01-01

    Positively charged electrostatic patches on protein surfaces are usually indicative of nucleic acid binding interfaces. Interestingly, many proteins which are not involved in nucleic acid binding possess large positive patches on their surface as well. In some cases, the positive patches on the protein are related to other functional properties of the protein family. PatchFinderPlus (PFplus) http://pfp.technion.ac.il is a web-based tool for extracting and displaying continuous electrostatic positive patches on protein surfaces. The input required for PFplus is either a four letter PDB code or a protein coordinate file in PDB format, provided by the user. PFplus computes the continuum electrostatics potential and extracts the largest positive patch for each protein chain in the PDB file. The server provides an output file in PDB format including a list of the patch residues. In addition, the largest positive patch is displayed on the server by a graphical viewer (Jmol), using a simple color coding. PMID:17537808

  13. A clinical study of transdermal contraceptive patch in Thai adolescence women.

    PubMed

    Piyasirisilp, Rachatapon; Taneepanichskul, Surasak

    2008-02-01

    To study cycle control, compliance and safety of a transdermal contraceptive patch in adolescent Thai women. Fifty-eight healthy women were assigned to receive 3 cycles of contraceptive patch (ethinyl estradiol 20 microg and norelgestromin 150 microg/day). All participants aged 16-20 years were invited to participate from the family planning clinic at King Chulalongkorn Memorial Hospital. Data were collected on adverse effects, perceived advantages and disadvantages, body weight, blood pressure, patch detachments and compliance. Data were analyzed using mean, percentage and student's t-test. The participants' average age was 19.4 years, height 158.8 cm, weight 51.8 kg, BMI 20.8 Kg/m2. The most location of patch application was the abdomen and the most adverse event was breast tenderness (31.0%) followed by application site reaction, nausea vomiting and headache respectively. The breast symptom was mild in severity. The participants reported decrease in dysmenorrhea and shorter duration of bleeding. There were no significant changes in body weight and blood pressure. The improvement of their facial acne was reported. There were no pregnancies during use and the adhesion of the contraceptive patch is excellent. Partial patch detachment was reported in only 6.9%. No completed patch detachment was found. The present study found an overall positive impression of a new transdermal contraceptive patch. The good compliance and few side effects were demonstrated. The adhesive patch contraceptive was excellent.

  14. Patch testing with hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) - a multicentre study of the Swedish Contact Dermatitis Research Group.

    PubMed

    Engfeldt, Malin; Hagvall, Lina; Isaksson, Marléne; Matura, Mihály; Mowitz, Martin; Ryberg, Kristina; Stenberg, Berndt; Svedman, Cecilia; Bruze, Magnus

    2017-01-01

    In 2014, the fragrance hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) was excluded from the Swedish baseline series. To study (i) whether fragrance mix (FM) II with 5% HICC detects more positive reactions than usual FM II with 2.5% HICC, and (ii) the reproducibility of patch testing with HICC. Two thousand one hundred and eighteen dermatitis patients at five Swedish dermatology departments were consecutively tested with FM II 14% pet., FM II 16.5% pet., and duplicate preparations of HICC 5% pet. Of the patients, 3.2% reacted to FM II 14%, and 1.5% reacted to HICC. Separate testing with HICC detected 0.3% reactions without concomitant reactivity to FM II. FM II with 5% HICC did not give rise to more irritant reactions or signs of active sensitization than FM II with 2.5% HICC. Patch testing with duplicate applications of HICC increased the overall prevalence of HICC contact allergy to 1.9%. FM II with 5% HICC does not detect more positive reactions than FM II with 2.5% HICC. Separate testing with HICC does not detect a sufficient proportion of patients who react only to HICC, without concomitant reactions to FM II, to warrant its inclusion in a baseline series. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Evaluation of the utility of atopy patch testing, skin prick testing, and total and specific IgE assays in the diagnosis of cow's milk allergy.

    PubMed

    Keskin, Ozlem; Tuncer, Ayfer; Adalioglu, Gonul; Sekerel, Bulent E; Sackesen, Cansin; Kalayci, Omer

    2005-05-01

    Information on the utility of atopy patch testing (APT) in the diagnosis of food allergy is derived from studies of children with atopic dermatitis. To evaluate the usefulness of APT in the diagnosis of cow's milk allergy (CMA) and to determine interleukin 4 and interferon-gamma production by peripheral blood mononuclear cells. Thirty-seven children (median age, 11 months) with suspected CMA who had a variety of symptoms that involved many organ systems were evaluated using double-blind placebo-controlled food challenges (DBPCFCs), and the performances of milk specific IgE, skin prick testing (SPT), and APT were determined. To search for a possible relationship between the diagnostic tests and the TH1/TH2 immune response, we measured interferon-gamma and interleukin 4 levels in the supernatants of peripheral blood mononuclear cell cultures. Seventeen children with positive DBPCFC results and 6 with a history of anaphylaxis were diagnosed as having CMA. The combined use of APT and SPT had a sensitivity of 100% and a negative predictive value of 100% but a specificity of 50% and a positive predictive value of 76%. The addition of milk specific IgE assays to APT and SPT did not improve these values. Pattern of cytokine secretion was not associated with APT positivity or a specific response to DBPCFC. Atopy patch testing may be a useful adjunct to SPT in excluding CMA in children who have allergic manifestations other than atopic dermatitis. However, DBPCFCs are still necessary in the presence of positive test results.

  16. Industrializing electrophysiology: HT automated patch clamp on SyncroPatch® 96 using instant frozen cells.

    PubMed

    Polonchuk, Liudmila

    2014-01-01

    Patch-clamping is a powerful technique for investigating the ion channel function and regulation. However, its low throughput hampered profiling of large compound series in early drug development. Fortunately, automation has revolutionized the area of experimental electrophysiology over the past decade. Whereas the first automated patch-clamp instruments using the planar patch-clamp technology demonstrated rather a moderate throughput, few second-generation automated platforms recently launched by various companies have significantly increased ability to form a high number of high-resistance seals. Among them is SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich, Germany), a fully automated giga-seal patch-clamp system with the highest throughput on the market. By recording from up to 96 cells simultaneously, the SyncroPatch(®) 96 allows to substantially increase throughput without compromising data quality. This chapter describes features of the innovative automated electrophysiology system and protocols used for a successful transfer of the established hERG assay to this high-throughput automated platform.

  17. Repeated faecal occult blood testing is associated with decreased advanced colorectal cancer risk: A population-based study.

    PubMed

    James, Paul D; Rabeneck, Linda; Yun, Lingsong; Paszat, Lawrence; Baxter, Nancy N; Govindarajan, Anand; Antonova, Lilia; Tinmouth, Jill M

    2017-01-01

    Objective To evaluate the association between repeated faecal occult blood testing and advanced colorectal cancer risk at population level in Canada. Methods A retrospective cohort study of all Ontario residents aged 56-74 diagnosed with colorectal cancer from 1 April 2007 to 31 March 2010, identified using health administrative data. The primary outcome was stage IV colorectal cancer, and primary exposure was faecal occult blood testing use within five years prior to colorectal cancer diagnosis. Patients were categorized into four mutually exclusive groups based on their exposure to faecal occult blood testing in the five years prior to colorectal cancer diagnosis: none, pre-diagnostic, repeated, and sporadic. Logistic regression was utilized to adjust for confounders. Results Of 7753 patients (median age 66, interquartile range 61-70, 62% male) identified, 1694 (22%) presented with stage I, 2056 (27%) with stage II, 2428 (31%) with stage III, and 1575 (20%) with stage IV colorectal cancer. There were 4092 (53%) with no record of prior faecal occult blood testing, 1485 (19%) classified as pre-diagnostic, 1693 (22%) as sporadic, and 483 (6%) as repeated faecal occult blood testing. After adjusting for confounders, patients who had repeated faecal occult blood testing were significantly less likely to present with stage IV colorectal cancer at diagnosis (Odds ratio 0.46, 95% Confidence Interval 0.34-0.62) than those with no prior faecal occult blood testing. Conclusions Repeated faecal occult blood testing is associated with a decreased risk of advanced colorectal cancer. Our findings support the use of organized screening programmes that employ repeated faecal occult blood testing to improve colorectal cancer outcomes at population level.

  18. Paths to tobacco abstinence: A repeated-measures latent class analysis.

    PubMed

    McCarthy, Danielle E; Ebssa, Lemma; Witkiewitz, Katie; Shiffman, Saul

    2015-08-01

    Knowledge of smoking change processes may be enhanced by identifying pathways to stable abstinence. We sought to identify latent classes of smokers based on their day-to-day smoking status in the first weeks of a cessation attempt. We examined treatment effects on class membership and compared classes on baseline individual differences and 6-month abstinence rates. In this secondary analysis of a double-blind randomized placebo-controlled clinical trial (N = 1,433) of 5 smoking cessation pharmacotherapies (nicotine patch, nicotine lozenge, bupropion SR, patch and lozenge, or bupropion SR and lozenge), we conducted repeated-measures latent class analysis of daily smoking status (any smoking vs. none) for the first 27 days of a quit attempt. Treatment and covariate relations with latent class membership were examined. Distal outcome analysis compared confirmed 6-month abstinence rates among the latent classes. A 5-class solution was selected. Three-quarters of smokers were in stable smoking or abstinent classes, but 25% were in classes with unstable abstinence probabilities over time. Active treatment (compared to placebo), and particularly the patch and lozenge combination, promoted early quitting. Latent classes differed in 6-month abstinence rates and on several baseline variables, including nicotine dependence, quitting history, self-efficacy, sleep disturbance, and minority status. Repeated-measures latent class analysis identified latent classes of smoking change patterns affected by treatment, related to known risk factors, and predictive of distal outcomes. Tracking behavior early in a change attempt may identify prognostic patterns of change and facilitate adaptive treatment planning. (c) 2015 APA, all rights reserved).

  19. Transdermal patches: history, development and pharmacology

    PubMed Central

    Pastore, Michael N; Kalia, Yogeshvar N; Horstmann, Michael; Roberts, Michael S

    2015-01-01

    Transdermal patches are now widely used as cosmetic, topical and transdermal delivery systems. These patches represent a key outcome from the growth in skin science, technology and expertise developed through trial and error, clinical observation and evidence-based studies that date back to the first existing human records. This review begins with the earliest topical therapies and traces topical delivery to the present-day transdermal patches, describing along the way the initial trials, devices and drug delivery systems that underpin current transdermal patches and their actives. This is followed by consideration of the evolution in the various patch designs and their limitations as well as requirements for actives to be used for transdermal delivery. The properties of and issues associated with the use of currently marketed products, such as variability, safety and regulatory aspects, are then described. The review concludes by examining future prospects for transdermal patches and drug delivery systems, such as the combination of active delivery systems with patches, minimally invasive microneedle patches and cutaneous solutions, including metered-dose systems. PMID:25560046

  20. Transdermal patches: history, development and pharmacology.

    PubMed

    Pastore, Michael N; Kalia, Yogeshvar N; Horstmann, Michael; Roberts, Michael S

    2015-05-01

    Transdermal patches are now widely used as cosmetic, topical and transdermal delivery systems. These patches represent a key outcome from the growth in skin science, technology and expertise developed through trial and error, clinical observation and evidence-based studies that date back to the first existing human records. This review begins with the earliest topical therapies and traces topical delivery to the present-day transdermal patches, describing along the way the initial trials, devices and drug delivery systems that underpin current transdermal patches and their actives. This is followed by consideration of the evolution in the various patch designs and their limitations as well as requirements for actives to be used for transdermal delivery. The properties of and issues associated with the use of currently marketed products, such as variability, safety and regulatory aspects, are then described. The review concludes by examining future prospects for transdermal patches and drug delivery systems, such as the combination of active delivery systems with patches, minimally invasive microneedle patches and cutaneous solutions, including metered-dose systems. © 2015 The British Pharmacological Society.

  1. Large-scale binding ligand prediction by improved patch-based method Patch-Surfer2.0

    PubMed Central

    Zhu, Xiaolei; Xiong, Yi; Kihara, Daisuke

    2015-01-01

    Motivation: Ligand binding is a key aspect of the function of many proteins. Thus, binding ligand prediction provides important insight in understanding the biological function of proteins. Binding ligand prediction is also useful for drug design and examining potential drug side effects. Results: We present a computational method named Patch-Surfer2.0, which predicts binding ligands for a protein pocket. By representing and comparing pockets at the level of small local surface patches that characterize physicochemical properties of the local regions, the method can identify binding pockets of the same ligand even if they do not share globally similar shapes. Properties of local patches are represented by an efficient mathematical representation, 3D Zernike Descriptor. Patch-Surfer2.0 has significant technical improvements over our previous prototype, which includes a new feature that captures approximate patch position with a geodesic distance histogram. Moreover, we constructed a large comprehensive database of ligand binding pockets that will be searched against by a query. The benchmark shows better performance of Patch-Surfer2.0 over existing methods. Availability and implementation: http://kiharalab.org/patchsurfer2.0/ Contact: dkihara@purdue.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25359888

  2. Cerebrovascular Injury Caused by a High Strain Rate Insult in the Thorax

    DTIC Science & Technology

    2012-01-17

    AD693105 3. Cernak I. Penetrating and blast injury. Restor Neurol Neurosci 2005; 23 139-143 4. Cernak I, Wang Z, Jiang J, Bian X, Savic J. Ultrastructural...insult in the thorax 4 5. Cernak I, Wang Z, Jiang J, Bian X, Savic J. Cognitive deficits following blast-induced neurotrauma: possible

  3. Sleep Deprivation and Recovery Sleep Prior to a Noxious Inflammatory Insult Influence Characteristics and Duration of Pain

    PubMed Central

    Vanini, Giancarlo

    2016-01-01

    Study Objectives: Insufficient sleep and chronic pain are public health epidemics. Sleep loss worsens pain and predicts the development of chronic pain. Whether previous, acute sleep loss and recovery sleep determine pain levels and duration remains poorly understood. This study tested whether acute sleep deprivation and recovery sleep prior to formalin injection alter post-injection pain levels and duration. Methods: Male Sprague-Dawley rats (n = 48) underwent sleep deprivation or ad libitum sleep for 9 hours. Thereafter, rats received a subcutaneous injection of formalin or saline into a hind paw. In the recovery sleep group, rats were allowed 24 h between sleep deprivation and the injection of formalin. Mechanical and thermal nociception were assessed using the von Frey test and Hargreaves' method. Nociceptive measures were performed at 1, 3, 7, 10, 14, 17 and 21 days post-injection. Results: Formalin caused bilateral mechanical hypersensitivity (allodynia) that persisted for up to 21 days post-injection. Sleep deprivation significantly enhanced bilateral allodynia. There was a synergistic interaction when sleep deprivation preceded a formalin injection. Rats allowed a recovery sleep period prior to formalin injection developed allodynia only in the injected limb, with higher mechanical thresholds (less allodynia) and a shorter recovery period. There were no persistent changes in thermal nociception. Conclusion: The data suggest that acute sleep loss preceding an inflammatory insult enhances pain and can contribute to chronic pain. The results encourage studies in a model of surgical pain to test whether enhancing sleep reduces pain levels and duration. Citation: Vanini G. Sleep deprivation and recovery sleep prior to a noxious inflammatory insult influence characteristics and duration of pain. SLEEP 2016;39(1):133–142. PMID:26237772

  4. Brain parenchyma PO2, PCO2, and pH during and after hypoxic, ischemic brain insult in dogs.

    PubMed

    McKinley, B A; Morris, W P; Parmley, C L; Butler, B D

    1996-11-01

    1) The investigation of fiberoptic PO2, PCO2, and pH sensor technology as a monitor of brain parenchyma during and after brain injury, and 2) the comparison of brain parenchyma PO2, PCO2, and pH with intracranial pressure during and after hypoxic, ischemic brain insult. Prospective, controlled, animal study in an acute experimental preparation. Physiology laboratory in a university medical school. Fourteen mongrel dogs (20 to 35 kg), anesthetized, room-air ventilated. Anesthesia was induced with thiopental and maintained after intubation using 1% to 1.5% halothane in room air (FiO2 0.21). Mechanical ventilation was established to maintain end-tidal PCO2 approximately 35 torr (-4.7 kPa). Intravenous, femoral artery, and pulmonary artery catheters were placed. The common carotid arteries were surgically exposed, and ultrasonic blood flow probes were applied. A calibrated intracranial pressure probe was placed through a right-side transcranial bolt, and a calibrated intracranial chemistry probe with optical sensors for PO2, PCO2, and pH was placed through a left-side bolt into brain parenchyma. Brain insult was induced in the experimental group (n = 6) by hypoxia (FiO2 0.1), ischemia (bilateral carotid artery occlusion), and hypotension (mean arterial pressure [MAP] approximately 40 mm Hg produced with isoflurane approximately 4%). After 45 mins, carotid artery occlusion was released, FiO2 was reset to 0.21, and anesthetic was returned to halothane (approximately 1.25%). The control group (n = 5) had the same surgical preparation and sequence of anesthetic agent exposure but no brain insult. Monitored variables included brain parenchyma PO2, PCO2, and pH, which were monitored at 1-min intervals, and intracranial pressure, MAP, arterial hemoglobin oxygen saturation (by pulse oximetry), end-tidal PCO2, and carotid artery blood flow rate, for which data were collected at 15-min intervals for 7 hrs. Arterial and mixed venous blood gas analyses were done at approximately 1

  5. Departure mechanisms for host search on high-density patches by the Meteorus pulchricornis.

    PubMed

    Sheng, Sheng; Feng, Sufang; Meng, Ling; Li, Baoping

    2014-01-01

    Less attention has been paid to the parasitoid-host system in which the host occurs in considerably high density with a hierarchical patch structure in studies on time allocation strategies of parasitoids. This study used the parasitoid Meteorus pulchricornis (Wesmael) (Hymenoptera: Braconidae) and the Oriental leafworm, Spodoptera litura (Fabricius) (Lepidoptera: Noctuidae) as the parasitoids-host model system to investigate patch-leaving mechanisms as affected by the high-host density, hierarchical patch structure, and foraging behaviors on both former and current patches. The results showed that three out of eight covariates tested had significant effects on the patch-leaving tendency, including the host density, ovipositor insertion, and host rejection on the current patch. The parasitoid paid more visits to the patch with high-density hosts. While the patch with higher host densities decreased the leaving tendency, the spatial distribution of hosts examined had no effect on the leaving tendency. Both oviposition and host rejection decreased the patch-leaving tendency. The variables associated with the former patch, such as the host density and number of ovipositor insertions, however, did not have an effect on the leaving tendency. Our study suggested that M. pulchricornis females may use an incremental mechanism to exploit high-density patches to the fullest. © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.

  6. Quantitative repeated open application testing with a rinse-off product in methyldibromo glutaronitrile-sensitive patients: results of the IVDK.

    PubMed

    Heratizadeh, Annice; Killig, Claudia; Worm, Margitta; Soost, Stephanie; Simon, Dagmar; Bauer, Andrea; Mahler, Vera; Schuster, Christian; Szliska, Christiane; Frambach, Yvonne; Eben, Ricarda; Werfel, Thomas; Uter, Wolfgang; Schnuch, Axel

    2010-06-01

    While the use of methyldibromo glutaronitrile (MDBGN) in leave-on products is clearly associated with high sensitization or elicitation risk, such a clear-cut relation could be questioned with regard to rinse-off products. The objective of this study was to find a maximum non-eliciting concentration for rinse-off products in MDBGN patch test-positive patients. We performed a use-related test [repeated open application test (ROAT)] in patients sensitized to MDBGN with a liquid soap containing three concentrations of MDBGN (50, 200, and 400 p.p.m. MDBGN, respectively). The soap at 50 p.p.m. was used twice daily for 4 weeks. If no reaction of the skin was observed, the product with the next higher concentration was used for another 4 weeks, etc. In total, 32/37 evaluated cases [86.5%; lower exact one-sided 95% confidence limit (CL): 73.7%] did not react to any of the preparations. The remaining reacted as follows: 1/37 reacted to 50 p.p.m., 3/37 to 200 p.p.m., and 1/37 to 400 p.p.m. The cumulative non-response to 50 p.p.m. was 97.3% (lower CL: 87.8%). The majority of subjects sensitized to MDBGN-tolerated rinse-off products containing a maximum concentration of 400 p.p.m. A concentration in rinse-off products in the range of 50 p.p.m. could be regarded as safe for most individuals already sensitized. These concentrations will presumably prevent induction (sensitization) also.

  7. Lidocaine 20% patch vs lidocaine 5% gel for topical anaesthesia of oral mucosa.

    PubMed

    Bågesund, Mats; Tabrizi, Parisa

    2008-11-01

    Topical anaesthetics are important to provide pain control at dental injection. The aim was to evaluate the effectiveness of the intraoral topical anaesthetics lidocaine 20% patch (DentiPatch) and lidocaine 5% gel. The randomized unblinded cross-over study included 31 patients (ten boys, 21 girls) aged 13.5 +/- 2.5 years. Application of lidocaine patch or gel was randomly used at first and second visit in the upper premolar region. Heart rate was measured before and at each needle insertion after 2.5, 5, and 15 min and at injection after 15 min. Discomfort and pain were expressed in visual analogue scales (VAS). Paired t-test and Mann-Whitney U-test were used for statistic analyses. Heart rate at buccal injection decreased more when the patch was used (P = 0.0149). Heart rate was lower at the second visit (P = 0.0287). Patients expressed less discomfort when the patch was used on both buccal (P = 0.0150) and palatal (P = 0.0391) site. Boys had lower heart rate and VAS pain scale ratings than girls. Good pain control can reduce the patients' anxiety level--expressed in heart rate--at the second appointment. The patch and gel seem to provide similar pain reduction at needle stick and injection of local anaesthetics.

  8. DyninstAPI Patches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeGendre, M.

    2012-04-01

    We are seeking a code review of patches against DyninstAPI 8.0. DyninstAPI is an open source binary instrumentation library from the University of Wisconsin and University of Maryland. Our patches port DyninstAPI to the BlueGene/P and BlueGene/Q systems, as well as fix DyninstAPI bugs and implement minor new features in DyninstAPI.

  9. Two decades of p-phenylenediamine and toluene-2,5-diamine patch testing - focus on co-sensitizations in the European baseline series and cross-reactions with chemically related substances.

    PubMed

    Vogel, Tatiana A; Heijnen, Rakita W; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise A

    2017-02-01

    Cross-reactions and co-sensitizations are of great importance in understanding contact allergy and exposure sources. To investigate common cross-reactions and co-sensitizations in p-phenylenediamine (PPD)-sensitized and toluene-2,5-diamine (TDA)-sensitized individuals. From our patch test population, 8036 patients patch tested with the European baseline series were extracted. Readings had to be performed at least on day 3 according to ICDRG guidelines. Two hundred and fifty-one patients were sensitized to PPD and/or TDA; 231 patients were sensitized to PPD, and 109 to TDA. Significant differences were observed regarding the strengths of patch test reactions to PPD and number of cross-reactions. For TDA, a difference was found between all reaction strengths, except between + and ++ strengths. PPD-sensitized individuals were more likely to be sensitized to carba mix, cobalt chloride, colophonium, p-tert-butyl phenolformaldehyde resin, paraben mix, and methylisothiazolinone. TDA-sensitized individuals were more often sensitized to carba mix. Cross-reactivity was commonly found among individuals sensitized to PPD or TDA, and was strongly related to the strength of the patch test reaction. Regarding co-sensitizations, a frequently appearing or common exposure source could not be determined. However, modification of the allergen by, for example, the skin microbiota may have caused the formation of molecules that are, for the human immune system, indistinguishable from PPD. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Repeatability of quantitative sensory testing in healthy cats in a clinical setting with comparison to cats with osteoarthritis.

    PubMed

    Addison, Elena S; Clements, Dylan N

    2017-12-01

    Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.

  11. Large-scale binding ligand prediction by improved patch-based method Patch-Surfer2.0.

    PubMed

    Zhu, Xiaolei; Xiong, Yi; Kihara, Daisuke

    2015-03-01

    Ligand binding is a key aspect of the function of many proteins. Thus, binding ligand prediction provides important insight in understanding the biological function of proteins. Binding ligand prediction is also useful for drug design and examining potential drug side effects. We present a computational method named Patch-Surfer2.0, which predicts binding ligands for a protein pocket. By representing and comparing pockets at the level of small local surface patches that characterize physicochemical properties of the local regions, the method can identify binding pockets of the same ligand even if they do not share globally similar shapes. Properties of local patches are represented by an efficient mathematical representation, 3D Zernike Descriptor. Patch-Surfer2.0 has significant technical improvements over our previous prototype, which includes a new feature that captures approximate patch position with a geodesic distance histogram. Moreover, we constructed a large comprehensive database of ligand binding pockets that will be searched against by a query. The benchmark shows better performance of Patch-Surfer2.0 over existing methods. http://kiharalab.org/patchsurfer2.0/ CONTACT: dkihara@purdue.edu Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. [Hapten selection for patch tests in the diagnosis of allergic contact dermatitis: epidemiologic data].

    PubMed

    Romano, C; Carosso, A; Bosio, D; Chiesa, A; Gullino, A; Turrini, A

    2003-01-01

    Aim of the study was to verify the reliability in clinical practice of patch testing with "standard" series and additional series of haptens for the diagnosis of occupational and non-occupational allergic contact dermatitis, evaluating positive reactions and relating those reactions to professional categories. A total of 392 out of 937 patients (41.8%) showed at least one positive reaction to "standard" series testing; the hapten most frequently noted as the cause of positive reaction was nickel sulphate. Professional categories that showed positive reactions to "standard" series most frequently were clerks, hairdressers and hospital auxiliary workers. Among 897 patients tested with nonstandard allergens, only 124 (13.8%) elicited at least one positive reaction, ammonium persulphate being the most frequently positive hapten. A dominant percentage of positive results was seen in hairdressers and cleaning personnel. No positive reactions were observed in a large number of haptens, tested more than 200 times. Haptens of "standard series" elicited a higher number of positive reaction than the additional series, even though there was a high specificity of few additional series haptens in some professional categories. Data suggest some caution in systematically testing additional series, despite a higher accuracy and diagnostic efficacy in some job categories.

  13. IL-18 cleavage triggers cardiac inflammation and fibrosis upon β-adrenergic insult.

    PubMed

    Xiao, Han; Li, Hao; Wang, Jing-Jing; Zhang, Jian-Shu; Shen, Jing; An, Xiang-Bo; Zhang, Cong-Cong; Wu, Ji-Min; Song, Yao; Wang, Xin-Yu; Yu, Hai-Yi; Deng, Xiang-Ning; Li, Zi-Jian; Xu, Ming; Lu, Zhi-Zhen; Du, Jie; Gao, Wei; Zhang, Ai-Hua; Feng, Yue; Zhang, You-Yi

    2018-01-01

    Rapid over-activation of β-adrenergic receptor (β-AR) upon stress leads to cardiac inflammation, a prevailing factor that underlies heart injury. However, mechanisms by which acute β-AR stimulation induce cardiac inflammation still remain unknown. Here, we set out to identify the crucial role of inflammasome/interleukin (IL)-18 in initiating and maintaining cardiac inflammatory cascades upon β-AR insult. Male C57BL/6 mice were injected with a single dose of β-AR agonist, isoproterenol (ISO, 5 mg/kg body weight) or saline subcutaneously. Cytokine array profiling demonstrated that chemokines dominated the initial cytokines upregulation specifically within the heart upon β-AR insult, which promoted early macrophage infiltration. Further investigation revealed that the rapid inflammasome-dependent activation of IL-18, but not IL-1β, was the critical up-stream regulator for elevated chemokine expression in the myocardium upon ISO induced β1-AR-ROS signalling. Indeed, a positive correlation was observed between the serum levels of norepinephrine and IL-18 in patients with chest pain. Genetic deletion of IL-18 or the up-stream inflammasome component NLRP3 significantly attenuated ISO-induced chemokine expression and macrophage infiltration. In addition, IL-18 neutralizing antibodies selectively abated ISO-induced chemokines, proinflammatory cytokines and adhesion molecules but not growth factors. Moreover, blocking IL-18 early after ISO treatment effectively attenuated cardiac inflammation and fibrosis. Inflammasome-dependent activation of IL-18 within the myocardium upon acute β-AR over-activation triggers cytokine cascades, macrophage infiltration and pathological cardiac remodelling. Blocking IL-18 at the early stage of β-AR insult can successfully prevent inflammatory responses and cardiac injuries. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  14. Transmission of Insult in Out-of-Position Subjects: III. Thoracic Spine Injury

    NASA Astrophysics Data System (ADS)

    Shaibani, Saami J.

    2004-03-01

    In two related papers,[1-2] the behavior of vehicle occupants subjected to low-severity insults was calculated. The same low level of impact was experienced by a train operator in the engine compartment studied here. It is important to recognize that the operator chair is totally different from passenger vehicle seats, which means that results for the latter cannot meaningfully be employed for the former. Instead, the chair design must be examined thoroughly to show that the top of the chair reaches only the mid-point of the operator's back and the line of the chair is rotated to the right of the line of forward travel. The first feature offers no protection against rearward motion of the upper body, and the second compounds this by twisting the body into a non-standard posture. Physics principles once again enabled consequent injury to be diagnosed. 1. Transmission of Insult in Out-of-Position Subjects: I. Shoulder Injury, Bull. Am. Phys. Soc., 47, 544 (2002); 2. ibid: II. Lumbosacral Injury.

  15. Repeatability testing of a new Hybrid III 6-year-old ATD lower extremity.

    PubMed

    Boucher, Laura C; Ryu, Yeonsu; Kang, Yun-Seok; Bolte, John H

    2017-05-29

    Vehicle safety is improving, thus decreasing the number of life-threatening injuries and increasing the need for research in other areas of the body. The current child anthropomorphic test device (ATD) does not have the capabilities or instrumentation to measure many of the potential interactions between the lower extremity and the vehicle interior. A prototype Hybrid III 6-year-old ATD lower extremity (ATD-LE) was developed and contains a tibia load cell and a more biofidelic ankle. The repeatability of the device has not yet been assessed; thus, the objective was to evaluate the repeatability of the ATD-LE. Additionally, a dynamic assessment was conducted to quantify injury threshold values. A pneumatic ram impactor was used at 2 velocities to evaluate repeatability. The ATD-LE was fixed to a table and impacted on the plantar aspect of the forefoot. Three repeated trials at 1.3 and 2.3 m/s without shoes and 2.3 m/s with shoes were conducted. The consistency of tibia force (N), bending moment (Nm), ankle range of motion (ROM, °), and stiffness (Nm/°) were quantified. A dynamic assessment using knee bolster airbag (KBA) tests was also conducted. The ATD-LE was positioned to mimic 3 worst-case scenarios: toes touching the mid-dashboard, touching the lower dashboard, and flat on the floor prior to airbag deployment. The impact responses in the femur and tibia were directly collected and compared with published injury threshold values. Ram impact testing indicated primarily excellent repeatability for the variables tested. For all 3 conditions the coefficients of variance (CV) were as follows: tibia force, 1.9-2.7%; tibia moment, 1.0-2.2%; ROM, 1.3-1.4%; ankle stiffness, 4.8-15.6%. The shoe-on condition resulted in a 25% reduction in tibia force and a 56% reduction in tibia bending moment. The KBA tests indicate that the highest injury risk may be when the toes touch the lower dashboard, due to the high bending moments recorded in the tibia at 76.2 Nm, which was

  16. Repeatability and uncertainty analyses of NASA/MSFC light gas gun test data

    NASA Technical Reports Server (NTRS)

    Schonberg, William P.; Cooper, David

    1993-01-01

    This Final Report presents an overview of the impact tests performed at NASA/MSFC in the time period 1985 to 1991 and the results of phenomena repeatability and data uncertainty studies performed using the information obtained from those tests. An analysis of the data from over 400 tests conducted between 1989 and 1991 was performed to generate a database to supplement the Hypervelocity Impact Damage Database developed under a previous effort.

  17. International Survey of Critically Ill Children With Acute Neurologic Insults: The Prevalence of Acute Critical Neurological Disease in Children: A Global Epidemiological Assessment Study.

    PubMed

    Fink, Ericka L; Kochanek, Patrick M; Tasker, Robert C; Beca, John; Bell, Michael J; Clark, Robert S B; Hutchison, Jamie; Vavilala, Monica S; Fabio, Anthony; Angus, Derek C; Watson, R Scott

    2017-04-01

    The international scope of critical neurologic insults in children is unknown. Our objective was to assess the prevalence and outcomes of children admitted to PICUs with acute neurologic insults. Prospective study. Multicenter (n = 107 PICUs) and multinational (23 countries, 79% in North America and Europe). Children 7 days to 17 years old admitted to the ICU with new traumatic brain injury, stroke, cardiac arrest, CNS infection or inflammation, status epilepticus, spinal cord injury, hydrocephalus, or brain mass. None. We evaluated the prevalence and outcomes of children with predetermined acute neurologic insults. Child and center characteristics were recorded. Unfavorable outcome was defined as change in pre-post insult Pediatric Cerebral Performance Category score greater than or equal to 2 or death at hospital discharge or 3 months, whichever came first. Screening data yielded overall prevalence of 16.2%. Of 924 children with acute neurologic insults, cardiac arrest (23%) and traumatic brain injury (19%) were the most common. All-cause mortality at hospital discharge was 12%. Cardiac arrest subjects had highest mortality (24%), and traumatic brain injury subjects had the most unfavorable outcomes (49%). The most common neurologic insult was infection/inflammation in South America, Asia, and the single African site but cardiac arrest in the remaining regions. Neurologic insults are a significant pediatric international health issue. They are frequent and contribute substantial morbidity and mortality. These data suggest a need for an increased focus on acute critical neurologic diseases in infants and children including additional research, enhanced availability of clinical resources, and the development of new therapies.

  18. Embedding silica and polymer fibre Bragg gratings (FBG) in plastic 3D-printed sensing patches

    NASA Astrophysics Data System (ADS)

    Zubel, Michal G.; Sugden, Kate; Webb, David J.; Sáez-Rodríguez, David; Nielsen, Kristian; Bang, Ole

    2016-04-01

    This paper reports the first demonstration of a silica fibre Bragg grating (SOFBG) embedded in an FDM 3-D printed housing to yield a dual grating temperature-compensated strain sensor. We also report the first ever integration of polymer fibre Bragg grating (POFBG) within a 3-D printed sensing patch for strain or temperature sensing. The cyclic strain performance and temperature characteristics of both devices are examined and discussed. The strain sensitivities of the sensing patches were 0.40 and 0.95 pm/μɛ for SOFBG embedded in ABS, 0.38 pm/μɛ for POFBG in PLA, and 0.15 pm/μɛ for POFBG in ABS. The strain response was linear above a threshold and repeatable. The temperature sensitivity of the SOFBG sensing patch was found to be up to 169 pm/°C, which was up to 17 times higher than for an unembedded silica grating. Unstable temperature response POFBG embedded in PLA was reported, with temperature sensitivity values varying between 30 and 40 pm/°C.

  19. Search for repeating events at the plate interface in the seismic sequence of the 2014 Mw8.1 Iquique earthquake, Chile

    NASA Astrophysics Data System (ADS)

    Kummerow, Joern; Asch, Guenter; Sens-Schönfelder, Christoph; Schurr, Bernd; Tilmann, Frederik; Shapiro, Serge A.

    2017-04-01

    The 2014 Mw8.1 Iquique earthquake occurred along a segment of the northern Chile- southern Peru seismic gap which had not ruptured for more than 100 years. A specific feature of this event is the observation of prominent foreshock clusters with successively increasing seismic moment releases starting several months before the main shock (e.g., Schurr et al., 2014). The entire seismic sequence, including also the aftershock seismicity, was monitored exceptionally well by the Integrated Plate Boundary Observatory Chile (IPOC). Here, we present results from a systematic, long-term search for repeating seismic events along the plate interface in the source region of the 1 April 2014 (Mw8.1) Iquique main shock. Repeating earthquakes are widely assumed to indicate recurrent ruptures on the same fault patch and to accommodate aseismic slip in the creeping portions around the seismic patch. According to this concept, the analysis of repeating events and of their temporal behaviour provides a tool to estimate the amount of creep. We use the IPOC and two additional local seismic networks and select recorded waveforms of several hundreds of located earthquakes within the foreshock and aftershock series as template events. Waveforms are windowed around the P and S phases and bandpass-filtered for different frequency bands. Window starts are defined by manually revised P onset times. We then run a newly implemented correlation detector on the resampled, continuous seismic data to find highly similar waveforms for each template event. Repeating earthquakes are finally identified by a combination of estimated source dimensions, high waveform similarity and precise relative relocations of the events within each multiplet group. The analysis of the spatial and temporal patterns of the detected repeating earthquake sequences allows to test the proposed idea of progressive unlocking of the plate boundary before the Iquique main shock.

  20. Aortic valve repair with autologous pericardial patch.

    PubMed

    Lausberg, Henning F; Aicher, Diana; Langer, Frank; Schäfers, Hans-Joachim

    2006-08-01

    Isolated aortic valve repair (AVR) has been gaining increasing interest in recent times. Results of isolated aortic valve repair have been reported to be variable. Various techniques have been utilized. We analyzed our experience with isolated valve repair using autologous pericardial patch plasty and compared the results to an age-matched collective with aortic valve repair without the use of additional material. Between January 1997 and June 2005, pericardial patch plasty of the aortic valve was performed in 42 patients (PATCH). During the same period, 42 patients after AVR without the use of additional material were age matched (NO-PATCH). Mean age in both groups was 52 years with a majority of male patients (PATCH ratio, 3.7:1; NO-PATCH ratio, 5:1). Valve anatomy was similar in both groups. All patients were followed by echocardiography for a cumulative follow-up of 2341 patient months (mean 28+/-23 months). No patient died in the hospital in neither group. The average systolic gradient was 5.9+/-2.2 mmHg in PATCH and 4.8+/-2.1 mmHg in NO-PATCH; p=0.17). Freedom from aortic regurgitation > or = II degrees was 87.8% in PATCH and 95.0% in NO-PATCH after 5 years (p=0.21). Freedom from reoperation was 97.6% in PATCH and 97.4% in NO-PATCH (p=0.96). Aortic regurgitation can be treated effectively by aortic valve repair using pericardial patch plasty. The functional results are satisfactory. With the application of this technique also more complex pathologies of the aortic valve can be addressed adequately thus extending the concept of valve preservation in patients with aortic regurgitation.

  1. Distributions-per-level: a means of testing level detectors and models of patch-clamp data.

    PubMed

    Schröder, I; Huth, T; Suitchmezian, V; Jarosik, J; Schnell, S; Hansen, U P

    2004-01-01

    Level or jump detectors generate the reconstructed time series from a noisy record of patch-clamp current. The reconstructed time series is used to create dwell-time histograms for the kinetic analysis of the Markov model of the investigated ion channel. It is shown here that some additional lines in the software of such a detector can provide a powerful new means of patch-clamp analysis. For each current level that can be recognized by the detector, an array is declared. The new software assigns every data point of the original time series to the array that belongs to the actual state of the detector. From the data sets in these arrays distributions-per-level are generated. Simulated and experimental time series analyzed by Hinkley detectors are used to demonstrate the benefits of these distributions-per-level. First, they can serve as a test of the reliability of jump and level detectors. Second, they can reveal beta distributions as resulting from fast gating that would usually be hidden in the overall amplitude histogram. Probably the most valuable feature is that the malfunctions of the Hinkley detectors turn out to depend on the Markov model of the ion channel. Thus, the errors revealed by the distributions-per-level can be used to distinguish between different putative Markov models of the measured time series.

  2. Hydroxyisohexyl 3-cyclohexene carboxaldehyde (lyral) in patch test preparations under varied storage conditions.

    PubMed

    Hamann, Dathan; Hamann, Carsten R; Zimerson, Erik; Bruze, Magnus

    2013-01-01

    The common practice of preparing patch tests in advance has recently been called into question by researchers. It has been established that fragrance compounds are volatile and their testing efficacy may be affected by storage conditions and preparation. Allergens in fragrance mix I rapidly decrease in concentration after preapplication to test chambers. This study aimed to investigate the volatility of hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) in petrolatum when stored in test chambers and to explore the correlation between vapor pressure and allergen loss in petrolatum during preparation and storage. Standardized HICC in petrolatum was prepared and stored in IQ Chambers and Finn Chambers with covers at 5°C, 25°C, and 35°C, and concentration was analyzed at intervals for up to 9 days using gel permeation chromatography. Changes in HICC concentrations were not statistically significant at 8 hours at 5°C, 25°C, and 35°C. After 9 days, HICC concentrations were found to fall approximately 30% when stored at 35°C, 10% at 25°C, and less than 5% at 5°C. There was no significant difference between IQ and Finn chambers. Hydroxyisohexyl 3-cyclohexene carboxaldehyde concentrations are more stable in petrolatum than many other studied fragrance allergens, but HICC is still at risk for decreasing concentration when exposed to ambient air or heat for prolonged periods.

  3. Patch testing with a new fragrance mix - reactivity to the individual constituents and chemical detection in relevant cosmetic products.

    PubMed

    Frosch, Peter J; Rastogi, Suresh C; Pirker, Claudia; Brinkmeier, Thomas; Andersen, Klaus E; Bruze, Magnus; Svedman, Cecilia; Goossens, An; White, Ian R; Uter, Wolfgang; Arnau, Elena Giménez; Lepoittevin, Jean-Pierre; Johansen, Jeanne Duus; Menne, Torkil

    2005-04-01

    A new fragrance mix (FM II), with 6 frequently used chemicals not present in the currently used fragrance mix (FM I), was evaluated in 6 dermatological centres in Europe, as previously reported. In this publication, test results with the individual constituents and after repeated open application test (ROAT) of FM II are described. Furthermore, cosmetic products which had caused a contact dermatitis in patients were analysed for the presence of the individual constituents. In 1701 patients, the individual constituents of the medium (14%) and the highest (28%) concentration of FM II were simultaneously applied with the new mix at 3 concentrations (break-down testing for the lowest concentration of FM II (2.8%) was performed only if the mix was positive). ROAT was performed with the concentration of the FM II which had produced a positive or doubtful (+ or ?+) patch test reaction. Patients' products were analysed for the 6 target compounds by gas chromatography-mass spectrometry (GC-MS). 50 patients (2.9%) showed a positive reaction to 14% FM II and 70 patients (4.1%) to 28% FM II. 24/50 (48%) produced a positive reaction to 1 or more of the individual constituents of 14% FM II and 38/70 (54.3%) to 28% FM II, respectively. If doubtful reactions to individual constituents are included, the break-down testing was positive in 74% and 70%, respectively. Patients with a positive reaction to 14% FM II showed a higher rate of reactions to the individual constituent of the 28% FM II: 36/50 (72%). Positive reactions to individual constituents in patients negative to FM II were exceedingly rare. If doubtful reactions are regarded as negative, the sensitivity, specificity, positive predictive value and negative predictive value for the medium concentration of FM II towards at least 1 individual constituent was 92.3% (exact 95% confidence interval 74.9-99.1%), 98.4% (97.7-99.0%), 48% (33.7-62.6%) and 99.9% (99.6-"100.0%), respectively. For the high concentration, the figures

  4. Repeatability of Cryogenic Multilayer Insulation

    NASA Technical Reports Server (NTRS)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-01-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4 whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 16. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  5. Repeatability of Cryogenic Multilayer Insulation

    NASA Technical Reports Server (NTRS)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-01-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between multiple identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five GRC provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons have been fabricated by Yetispace and tested by Florida State University, through the first 4 tests, the repeatability has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  6. Edge of polar cap patches

    NASA Astrophysics Data System (ADS)

    Hosokawa, K.; Taguchi, S.; Ogawa, Y.

    2016-04-01

    On the night of 4 December 2013, a sequence of polar cap patches was captured by an all-sky airglow imager (ASI) in Longyearbyen, Norway (78.1°N, 15.5°E). The 630.0 nm airglow images from the ASI of 4 second exposure time, oversampled the emission of natural lifetime (with quenching) of at least ˜30 sec, introduce no observational blurring effects. By using such high-quality ASI images, we succeeded in visualizing an asymmetry in the gradients between the leading/trailing edges of the patches in a 2-D fashion. The gradient in the leading edge was found to be 2-3 times steeper than that in the trailing edge. We also identified fingerlike structures, appearing only along the trailing edge of the patches, whose horizontal scale size ranged from 55 to 210 km. These fingers are considered to be manifestations of plasma structuring through the gradient-drift instability (GDI), which is known to occur only along the trailing edge of patches. That is, the current 2-D observations visualized, for the first time, how GDI stirs the patch plasma and such a mixing process makes the trailing edge more gradual. This result strongly implies a close connection between the GDI-driven plasma stirring and the asymmetry in the large-scale shape of patches and then suggests that the fingerlike structures can be used as markers to estimate the fine-scale structure in the plasma flow within patches.

  7. Slime moulds use heuristics based on within-patch experience to decide when to leave.

    PubMed

    Latty, Tanya; Beekman, Madeleine

    2015-04-15

    Animals foraging in patchy, non-renewing or slowly renewing environments must make decisions about how long to remain within a patch. Organisms can use heuristics ('rules of thumb') based on available information to decide when to leave the patch. Here, we investigated proximate patch-departure heuristics in two species of giant, brainless amoeba: the slime moulds Didymium bahiense and Physarum polycephalum. We explicitly tested the importance of information obtained through experience by eliminating chemosensory cues of patch quality. In P. polycephalum, patch departure was influenced by the consumption of high, and to a much lesser extent low, quality food items such that engulfing a food item increased patch-residency time. Physarum polycephalum also tended to forage for longer in darkened, 'safe' patches. In D. bahiense, engulfment of any food item increased patch residency irrespective of that food item's quality. Exposure to light had no effect on the patch-residency time of D. bahiense. Given that these organisms lack a brain, our results illustrate how the use of simple heuristics can give the impression that individuals make sophisticated foraging decisions. © 2015. Published by The Company of Biologists Ltd.

  8. SU-D-213-07: Initial Characterization of a Gel Patch Dosimeter for in Vivo Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matrosic, C; Culberson, W; Rosen, B

    Purpose: In vivo dosimetry, despite being the most direct method for monitoring the dose delivered during radiation therapy and being recommended by several national and international organizations (AAPM, ICRU, NACP), is underutilized in the clinic due to issues associated with dose sensitivity, feasibility, and cost. Given the increasing complexity of radiation therapy modern treatments, there is a compelling need for a robust, affordable in vivo dosimetry option. In this work we present the initial characterization of a novel gel patch in vivo dosimeter. Methods: DEFGEL (6%T) was used to make 1-cm thick small cylindrical patch dosimeters. The optical density ofmore » each dosimeter was read before and after irradiation by an in-house laser densitometer. The dosimeters were irradiated using a Varian Clinac EX linac. Three separate batches of gel patches were used to create dose response curves and evaluate repeatability. The development time of the dosimeter was also evaluated. Results: The dose response of the dosimeter was found to be linear from a range of approximately 1-Gy to 20-Gy, which is a larger window of linearity compared to other in vivo dosimeters. At doses below 1-Gy, the cumulative uncertainties were on the order of the measured data. When compared, the three batches demonstrated repeatability from 1-Gy to approximately 13-Gy, with some variation at higher doses. For doses of >8-Gy, the dosimeter reached full optical density after 4-hours, whereas low doses developed within an hour. Conclusion: Initial results indicate that the gel patch dosimeter is a reliable and simple way to measure a large range of doses, including high doses such as those delivered during hypofractionated treatments (e.g. SBRT or MR-guided radiotherapy). The simple fabrication method for the dosimeter and the use of a laser densitometer would allow for the dosimeter to used and read in-house, cheaply and easily.« less

  9. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    ERIC Educational Resources Information Center

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  10. Influence of habitat quality, population size, patch size, and connectivity on patch-occupancy dynamics of the middle spotted woodpecker.

    PubMed

    Robles, Hugo; Ciudad, Carlos

    2012-04-01

    Despite extensive research on the effects of habitat fragmentation, the ecological mechanisms underlying colonization and extinction processes are poorly known, but knowledge of these mechanisms is essential to understanding the distribution and persistence of populations in fragmented habitats. We examined these mechanisms through multiseason occupancy models that elucidated patch-occupancy dynamics of Middle Spotted Woodpeckers (Dendrocopos medius) in northwestern Spain. The number of occupied patches was relatively stable from 2000 to 2010 (15-24% of 101 patches occupied every year) because extinction was balanced by recolonization. Larger and higher quality patches (i.e., higher density of oaks >37 cm dbh [diameter at breast height]) were more likely to be occupied. Habitat quality (i.e., density of large oaks) explained more variation in patch colonization and extinction than did patch size and connectivity, which were both weakly associated with probabilities of turnover. Patches of higher quality were more likely to be colonized than patches of lower quality. Populations in high-quality patches were less likely to become extinct. In addition, extinction in a patch was strongly associated with local population size but not with patch size, which means the latter may not be a good surrogate of population size in assessments of extinction probability. Our results suggest that habitat quality may be a primary driver of patch-occupancy dynamics and may increase the accuracy of models of population survival. We encourage comparisons of competing models that assess occupancy, colonization, and extinction probabilities in a single analytical framework (e.g., dynamic occupancy models) so as to shed light on the association of habitat quality and patch geometry with colonization and extinction processes in different settings and species. ©2012 Society for Conservation Biology.

  11. FuncPatch: a web server for the fast Bayesian inference of conserved functional patches in protein 3D structures.

    PubMed

    Huang, Yi-Fei; Golding, G Brian

    2015-02-15

    A number of statistical phylogenetic methods have been developed to infer conserved functional sites or regions in proteins. Many methods, e.g. Rate4Site, apply the standard phylogenetic models to infer site-specific substitution rates and totally ignore the spatial correlation of substitution rates in protein tertiary structures, which may reduce their power to identify conserved functional patches in protein tertiary structures when the sequences used in the analysis are highly similar. The 3D sliding window method has been proposed to infer conserved functional patches in protein tertiary structures, but the window size, which reflects the strength of the spatial correlation, must be predefined and is not inferred from data. We recently developed GP4Rate to solve these problems under the Bayesian framework. Unfortunately, GP4Rate is computationally slow. Here, we present an intuitive web server, FuncPatch, to perform a fast approximate Bayesian inference of conserved functional patches in protein tertiary structures. Both simulations and four case studies based on empirical data suggest that FuncPatch is a good approximation to GP4Rate. However, FuncPatch is orders of magnitudes faster than GP4Rate. In addition, simulations suggest that FuncPatch is potentially a useful tool complementary to Rate4Site, but the 3D sliding window method is less powerful than FuncPatch and Rate4Site. The functional patches predicted by FuncPatch in the four case studies are supported by experimental evidence, which corroborates the usefulness of FuncPatch. The software FuncPatch is freely available at the web site, http://info.mcmaster.ca/yifei/FuncPatch golding@mcmaster.ca Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. Ion channel electrophysiology via integrated planar patch-clamp chip with on-demand drug exchange.

    PubMed

    Chen, Chang-Yu; Tu, Ting-Yuan; Jong, De-Shien; Wo, Andrew M

    2011-06-01

    Planar patch clamp has revolutionized characterization of ion channel behavior in drug discovery primarily via advancement in high throughput. Lab use of planar technology, however, addresses different requirements and suffers from inflexibility to enable wide range of interrogation via a single cell. This work presents integration of planar patch clamp with microfluidics, achieving multiple solution exchanges for tailor-specific measurement and allowing rapid replacement of the cell-contacting aperture. Studies via endogenously expressed ion channels in HEK 293T cells were commenced to characterize the device. Results reveal the microfluidic concentration generator produces distinct solution/drug combination/concentrations on-demand. Volume-regulated chloride channel and voltage-gated potassium channels in HEK 293T cells immersed in generated solutions under various osmolarities or drug concentrations show unique channel signature under specific condition. Excitation and blockage of ion channels in a single cell was demonstrated via serial solution exchange. Robustness of the reversible bonding and ease of glass substrate replacement were proven via repeated usage of the integrated device. The present approach reveals the capability and flexibility of integrated microfluidic planar patch-clamp system for ion channel assays. Copyright © 2011 Wiley Periodicals, Inc.

  13. Adenosine-loaded dissolving microneedle patches to improve skin wrinkles, dermal density, elasticity and hydration.

    PubMed

    Kang, G; Tu, T N T; Kim, S; Yang, H; Jang, M; Jo, D; Ryu, J; Baek, J; Jung, H

    2018-04-01

    Although dissolving microneedle patches have been widely studied in the cosmetics field, no comparisons have been drawn with the topical applications available for routine use. In this study, two wrinkle-improving products, adenosine-loaded dissolving microneedle patches and an adenosine cream, were evaluated for efficacy, with respect to skin wrinkling, dermal density, elasticity, and hydration, and safety in a clinical test on the crow's feet area. Clinical efficacy and safety tests were performed for 10 weeks on 22 female subjects with wrinkles around their eyes. The adenosine-loaded dissolving microneedle patch was applied once every 3 days, in the evening, for 8 weeks to the designated crow's feet area. The adenosine cream was applied two times per day, in the morning and evening, for 8 weeks to the other crow's feet area. Skin wrinkling, dermal density, elasticity, and hydration were measured by using PRIMOS ® premium, Dermascan ® C, Cutometer ® MPA580, and Corneometer ® CM 825, respectively. In addition, subjective skin irritation was evaluated by self-observation, and objective skin irritation was assessed through expert interviews. The adenosine-loaded dissolving microneedle patches had a similar or better efficacy than the adenosine cream. Both groups showed statistically significant efficacy for almost all parameters (P < 0.05). The dissolving microneedle patches had a long-lasting effect on the average wrinkle depth (P < 0.05), only showed efficacy in dermal density (P < 0.05), had an early improving effect on elasticity (P < 0.05), and demonstrated better hydration efficacy (P < 0.001). No adverse effects were observed in either group during the test period. In the clinical efficacy test of four skin-improvement parameters, adenosine-loaded dissolving microneedle patches showed the same or better effect than the adenosine cream, although the weekly adenosine dose was 140 times lower. The dissolving microneedle patches caused no

  14. Patch-clamp amplifiers on a chip

    PubMed Central

    Weerakoon, Pujitha; Culurciello, Eugenio; Yang, Youshan; Santos-Sacchi, Joseph; Kindlmann, Peter J.; Sigworth, Fred J.

    2010-01-01

    We present the first, fully-integrated, two-channel implementation of a patch-clamp measurement system. With this “PatchChip” two simultaneous whole-cell recordings can be obtained with rms noise of 8 pA in a 10 kHz bandwidth. The capacitance and series-resistance of the electrode can be compensated up to 10 pF and 100 MΩ respectively under computer control. Recordings of hERG and Nav 1.7 currents demonstrate the system's capabilities, which are on par with large, commercial patch-clamp instrumentation. By reducing patch-clamp amplifiers to a millimeter size micro-chip, this work paves the way to the realization of massively-parallel, high-throughput patch-clamp systems for drug screening and ion-channel research. The PatchChip is implemented in a 0.5 μm silicon-on-sapphire process; its size is 3 × 3 mm2 and the power consumption is 5 mW per channel with a 3.3 V power supply. PMID:20637803

  15. 1H NMR Spectroscopy-Based Metabolomic Assessment of Uremic Toxicity, with Toxicological Outcomes, in Male Rats Following an Acute, Mid-Life Insult from Ochratoxin A

    PubMed Central

    Mantle, Peter G.; Nicholls, Andrew W.; Shockcor, John P.

    2011-01-01

    Overt response to a single 6.25 mg dose of ochratoxin A (OTA) by oral gavage to 15 months male rats was progressive loss of weight during the following four days. Lost weight was restored within one month and animals had a normal life-span without OTA-related terminal disease. Decline in plasma OTA concentration only commenced four days after dosing, while urinary excretion of OTA and ochratoxin alpha was ongoing. During a temporary period of acute polyuria, a linear relationship between urine output and creatinine concentration persisted. Elimination of other common urinary solutes relative to creatinine was generally maintained during the polyuria phase, except that phosphate excretion increased temporarily. 1H NMR metabolomic analysis of urine revealed a progressive cyclic shift in the group principal components data cluster from before dosing, throughout the acute insult phase, and returning almost completely to normality when tested six months later. Renal insult by OTA was detected by 1H NMR within a day of dosing, as the most sensitive early indicator. Notable biomarkers were trimethylamine N-oxide and an aromatic urinary profile dominated by phenylacetylglycine. Tolerance of such a large acute insult by OTA, assessed by rat natural lifetime outcomes, adds a new dimension to toxicology of this xenobiotic. PMID:22069722

  16. Comparison between over-glasses patching and adhesive patching for children with moderate amblyopia: a prospective randomized clinical trial.

    PubMed

    Kim, Su Jin; Jeon, Hyeshin; Jung, Jae Ho; Lee, Kwang Min; Choi, Hee Young

    2018-02-01

    To investigate efficacy of over-glasses patching treatment for amblyopic children using visual function improvement and Amblyopia Treatment Index (ATI) changes. In a randomized multi-center controlled clinical trial, 107 children aged 3-7 years with moderate amblyopia (visual acuity in the range of 20/40 to 20/100) were included to receive treatment with either an adhesive skin patch or a fabric over-glasses patch. The patients were prescribed 2 h of patching per day for the sound eye. Best-corrected visual acuity (BCVA) was investigated and ATI questionnaires were collected from parents at 5 weeks and 17 weeks after the initiation of treatment. ATI identifies barriers and problems associated with amblyopia treatment. We compared the changes of visual acuity of amblyopic eyes and ATI scores in two groups. At 17 weeks, the mean visual acuity of the amblyopic eye using Snellen chart improved 3.2 lines in the adhesive patching group and 2.7 lines for an over-glasses patching method that fit over eyeglasses (p = 0.345). A similar proportion of subjects in each group had improvement of ≥ 2 lines (adhesive patching group 67% vs over-glasses patching group 67%, p = 0.372). There was also no difference in treatment burden in each group as measured with the Amblyopia Treatment Index. The only item to demonstrate a significant difference between groups was that related to "Treatment makes the eye or eyelids red" (mean 4.0 ± 1.1 vs 3.0 ± 1.0 at 17 weeks, p = 0.001, for adhesive vs over-glasses patch). Over-glasses patching treatment is a useful option for amblyopia treatment when the patients suffer from adverse effects of using adhesive skin patching.

  17. Exploring repeat HIV testing among men who have sex with men in Cape Town and Port Elizabeth, South Africa.

    PubMed

    Siegler, Aaron J; Sullivan, Patrick S; de Voux, Alex; Phaswana-Mafuya, Nancy; Bekker, Linda-Gail; Baral, Stefan D; Winskell, Kate; Kose, Zamakayise; Wirtz, Andrea L; Brown, Ben; Stephenson, Rob

    2015-01-01

    Despite the high prevalence of HIV among men who have sex with men (MSM) - and the general adult population - in South Africa, there is little data regarding the extent to which MSM seek repeat testing for HIV. This study explores reported histories of HIV testing, and the rationales for test seeking, among a purposive sample of 34 MSM in two urban areas of South Africa. MSM participated in activity-based in-depth interviews that included a timeline element to facilitate discussion. Repeat HIV testing was limited among participants, with three-quarters having two or fewer lifetime HIV tests, and over one-third of the sample having one or fewer lifetime tests. For most repeat testers, the time gap between their HIV tests was greater than the one-year interval recommended by national guidelines. Analysis of the reasons for seeking HIV testing revealed several types of rationale. The reasons for a first HIV test were frequently one-time occurrences, such as a requirement prior to circumcision, or motivations likely satisfied by a single HIV test. For MSM who reported repeat testing at more timely intervals, the most common rationale was seeking test results with a sex partner. Results indicate a need to shift HIV test promotion messaging and programming for MSM in South Africa away from a one-off model to one that frames HIV testing as a repeated, routine health maintenance behavior.

  18. Microstrip Patch Sensor for Salinity Determination.

    PubMed

    Lee, Kibae; Hassan, Arshad; Lee, Chong Hyun; Bae, Jinho

    2017-12-18

    In this paper, a compact microstrip feed inset patch sensor is proposed for measuring the salinities in seawater. The working principle of the proposed sensor depends on the fact that different salinities in liquid have different relative permittivities and cause different resonance frequencies. The proposed sensor can obtain better sensitivity to salinity changes than common sensors using conductivity change, since the relative permittivity change to salinity is 2.5 times more sensitive than the conductivity change. The patch and ground plane of the proposed sensor are fabricated by conductive copper spray coating on the masks made by 3D printer. The fabricated patch and the ground plane are bonded to a commercial silicon substrate and then attached to 5 mm-high chamber made by 3D printer so that it contains only 1 mL seawater. For easy fabrication and testing, the maximum resonance frequency was selected under 3 GHz and to cover salinities in real seawater, it was assumed that the salinity changes from 20 to 35 ppt. The sensor was designed by the finite element method-based ANSYS high-frequency structure simulator (HFSS), and it can detect the salinity with 0.01 ppt resolution. The designed sensor has a resonance frequency separation of 37.9 kHz and reflection coefficients under -20 dB at the resonant frequencies. The fabricated sensor showed better performance with average frequency separation of 48 kHz and maximum reflection coefficient of -35 dB. By comparing with the existing sensors, the proposed compact and low-cost sensor showed a better detection capability. Therefore, the proposed patch sensor can be utilized in radio frequency (RF) tunable sensors for salinity determination.

  19. Dairy farm effluent effects on urine patch nitrous oxide and carbon dioxide emissions.

    PubMed

    Clough, Tim J; Kelliher, Francis M

    2005-01-01

    Dairy farm effluent (DFE) comprises animal feces, urine, and wash-down water collected at the milking shed. This is collected daily during the milking season and sprayed onto grazed dairy pastures. Urine patches in grazed pastures make a significant contribution to anthropogenic N(2)O emissions. The DFE could potentially mitigate N(2)O emissions by influencing the N(2)O to dinitrogen (N(2)) ratio, since it contains water-soluble carbon (WSC). Alternatively, DFE may enhance N(2)O emissions from urine patches. The application of DFE may also provide a substrate for the production of CO(2) in pasture soils. The effects of DFE on the CO(2) and N(2)O emissions from urine patches are unknown. Thus a laboratory experiment was performed where repeated DFE applications were made to repacked soil cores. Dairy farm effluent was applied at 0, 7, or 14 d after urine deposition. The urine was applied once on Day 0. Urine contained (15)N-enriched urea. Measurements of N(2)O, N(2), and carbon dioxide (CO(2)) fluxes, soil pH, and soil inorganic N concentrations were made. After 43 d the DFE had not mitigated N(2)O fluxes from urine patches. A small increase in the N(2)O flux occurred from the urine-treated soils where DFE was applied 1 wk after urine deposition. The amount of WSC applied in the DFE proved to be insignificant compared with the amount of soil C released as CO(2) following urine application. The priming of soil C in urine patches has implications for the understanding of soil C processes in grazed pasture ecosystems and the budgeting of C within these ecosystems.

  20. Higher Drop in Speed during a Repeated Sprint Test in Soccer Players Reporting Former Hamstring Strain Injury

    PubMed Central

    Røksund, Ola D.; Kristoffersen, Morten; Bogen, Bård E.; Wisnes, Alexander; Engeseth, Merete S.; Nilsen, Ann-Kristin; Iversen, Vegard V.; Mæland, Silje; Gundersen, Hilde

    2017-01-01

    Aim: Hamstring strain injury is common in soccer. The aim of this study was to evaluate the physical capacity of players who have and have not suffered from hamstring strain injury in a sample of semi-professional and professional Norwegian soccer players in order to evaluate characteristics and to identify possible indications of insufficient rehabilitation. Method: Seventy-five semi-professional and professional soccer players (19 ± 3 years) playing at the second and third level in the Norwegian league participated in the study. All players answered a questionnaire, including one question about hamstring strain injury (yes/no) during the previous 2 years. They also performed a 40 m maximal sprint test, a repeated sprint test (8 × 20 m), a countermovement jump, a maximal oxygen consumption (VO2max) test, strength tests and flexibility tests. Independent sample t-tests were used to evaluate differences in the physical capacity of the players who had suffered from hamstring strain injury and those who had not. Mixed between-within subject's analyses of variance was used to compare changes in speed during the repeated sprint test between groups. Results: Players who reported hamstring strain injury during the previous two years (16%) had a significantly higher drop in speed (0.07 vs. 0.02 s, p = 0.007) during the repeated sprint test, compared to players reporting no previous hamstring strain injury. In addition, there was a significant interaction (groups × time) (F = 3.22, p = 0.002), showing that speed in the two groups changed differently during the repeated sprint test. There were no significant differences in relations to age, weight, height, body fat, linear speed, countermovement jump height, leg strength, VO2max, or hamstring flexibility between the groups. Conclusion: Soccer players who reported hamstring strain injury during the previous 2 years showed significant higher drop in speed during the repeated sprint test compared to players with no hamstring

  1. Identification and testing of early indicators for N leaching from urine patches.

    PubMed

    Vogeler, Iris; Cichota, Rogerio; Snow, Val

    2013-11-30

    Nitrogen leaching from urine patches has been identified as a major source of nitrogen loss under intensive grazing dairy farming. Leaching is notoriously variable, influenced by management, soil type, year-to-year variation in climate and timing and rate of urine depositions. To identify early indicators for the risk of N leaching from urine patches for potential usage in a precision management system, we used the simulation model APSIM (Agricultural Production Systems SIMulator) to produce an extensive N leaching dataset for the Waikato region of New Zealand. In total, nearly forty thousand simulation runs with different combinations of soil type and urine deposition times, in 33 different years, were done. The risk forecasting indicators were chosen based on their practicality: being readily measured on farm (soil water content, temperature and pasture growth) or that could be centrally supplied to farms (such as actual and forecast weather data). The thresholds of the early indicators that are used to forecast a period for high risk of N leaching were determined via classification and regression tree analysis. The most informative factors were soil temperature, pasture dry matter production, and average soil water content in the top soil over the two weeks prior to the urine N application event. Rainfall and air temperature for the two weeks following urine deposition were also important to fine-tune the predictions. The identified early indicators were then tested for their potential to predict the risk of N leaching in two typical soils from the Waikato region in New Zealand. The accuracy of the predictions varied with the number of indicators, the soil type and the risk level, and the number of correct predictions ranged from about 45 to over 90%. Further expansion and fine-tuning of the indicators and the development of a practical N risk tool based on these indicators is needed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. A case of acute generalized exanthematous pustulosis due to amoxicillin-clavulanate with multiple positivity to beta-lactam patch testing.

    PubMed

    Bomarrito, L; Zisa, G; Delrosso, G; Farinelli, P; Galimberti, M

    2013-09-01

    We present a case of acute generalized exanthematous pustolosis (AGEP) induced by amoxicillin-clavulanate. Clinical diagnosis was confirmed by symptoms presentation and  histological features (Euroscar score point compatible with definite diagnosis). Patch testing performer six months later confirmed sensitization to the culprit drug and showed positivity also to other beta-lactam antibiotics (penicillin G and cephalexin). We believe that a T cell delayed response to betalactams common ring could be involved.

  3. A rivastigmine patch for the treatment of Alzheimer's disease and Parkinson's disease dementia.

    PubMed

    Cummings, Jeffrey; Winblad, Bengt

    2007-11-01

    Rivastigmine patch is the first transdermal treatment to be approved for Alzheimer's disease (AD) and Parkinson's disease dementia in the USA and for AD in Europe. It provides smooth, continuous drug delivery, and has the potential to maintain rivastigmine concentrations within an optimal therapeutic window while avoiding the peaks and troughs associated with oral drug delivery. The target dose, rivastigmine 9.5 mg/24 h patch (a 10 cm(2) patch), is given once daily and requires a simple one-step dose titration to the therapeutic dose. In a 24-week study in 1195 AD patients, the rivastigmine 9.5 mg/24 h patch provided similar efficacy to the highest dose range of capsules, with approximately three-times fewer reports of nausea and vomiting. Patients in the 9.5 mg/24 h patch and 12 mg/day capsule groups evidenced significant improvements versus placebo on both primary outcome measures: the Alzheimer's Disease Assessment Scale-Cognitive subscale; and Alzheimer's Disease Cooperative Study-Clinical Global Impression of Change; in addition to the following secondary outcome measures: Alzheimer's Disease Cooperative Study-Activities of Daily Living scale; Mini-Mental State Examination; and Trail Making Test Part A for assessment of attention, visual tracking and motor processing speed. Treatment differences on the Neuropsychiatric Inventory and Ten Point Clock-drawing Test did not reach statistical significance in this study. The patch may be the optimal way to treat dementia patients with rivastigmine.

  4. Patch forest: a hybrid framework of random forest and patch-based segmentation

    NASA Astrophysics Data System (ADS)

    Xie, Zhongliu; Gillies, Duncan

    2016-03-01

    The development of an accurate, robust and fast segmentation algorithm has long been a research focus in medical computer vision. State-of-the-art practices often involve non-rigidly registering a target image with a set of training atlases for label propagation over the target space to perform segmentation, a.k.a. multi-atlas label propagation (MALP). In recent years, the patch-based segmentation (PBS) framework has gained wide attention due to its advantage of relaxing the strict voxel-to-voxel correspondence to a series of pair-wise patch comparisons for contextual pattern matching. Despite a high accuracy reported in many scenarios, computational efficiency has consistently been a major obstacle for both approaches. Inspired by recent work on random forest, in this paper we propose a patch forest approach, which by equipping the conventional PBS with a fast patch search engine, is able to boost segmentation speed significantly while retaining an equal level of accuracy. In addition, a fast forest training mechanism is also proposed, with the use of a dynamic grid framework to efficiently approximate data compactness computation and a 3D integral image technique for fast box feature retrieval.

  5. Repeatability of Cryogenic Multilayer Insulation

    NASA Astrophysics Data System (ADS)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-12-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation (MLI) has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five Glenn Research Center (GRC) provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons has been fabricated by Yetispace and tested by Florida State University, the repeatability between coupons has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  6. Irritancy ranking of 31 cleansers in the Indian market in a 24-h patch test.

    PubMed

    Lakshmi, C; Srinivas, C R; Anand, C V; Mathew, A C

    2008-08-01

    soap and Elovera moisturizing body wash which tested acidic (pH 5-6). The pH of the positive control--20% SDS, was acidic (pH 6). The difference in the irritancy potential between soaps/cleansers as determined by the 24-h patch test was significant. There were individual variations in the irritant potential of the soaps/cleansers in the volunteers, thus when the patient queries on what soap to use, it may be advisable to test each patient separately and educate him/her regarding the soaps/cleansers less likely to cause irritation. The limitations of the study was that it was single blind and non-randomized as all the 14 soap solutions were applied on 15 volunteers in the first panel and subsequently all the 17 soap solutions were applied on eight volunteers in the second panel. However, we could compare the irritant potential of 31 cleansers. The results of 24-h patch testing of 31 soaps/cleansers in the Indian market in two panels of 14 and 17 soaps/cleansers on 15 and eight volunteers, respectively, are presented.

  7. Metapopulation responses to patch connectivity and quality are masked by successional habitat dynamics.

    PubMed

    Hodgson, Jenny A; Moilanen, Atte; Thomas, Chris D

    2009-06-01

    Many species have to track changes in the spatial distribution of suitable habitat from generation to generation. Understanding the dynamics of such species will likely require spatially explicit models, and patch-based metapopulation models are potentially appropriate. However, relatively little attention has been paid to developing metapopulation models that include habitat dynamics, and very little to testing the predictions of these models. We tested three predictions from theory about the differences between dynamic habitat metapopulations and their static counterparts using long-term survey data from two metapopulations of the butterfly Plebejus argus. As predicted, we showed first that the metapopulation inhabiting dynamic habitat had a lower level of habitat occupancy, which could not be accounted for by other differences between the metapopulations. Secondly, we found that patch occupancy did not significantly increase with increasing patch connectivity in dynamic habitat, whereas there was a strong positive connectivity-occupancy relationship in static habitat. Thirdly, we found no significant relationship between patch occupancy and patch quality in dynamic habitat, whereas there was a strong, positive quality-occupancy relationship in static habitat. Modeling confirmed that the differences in mean patch occupancy and connectivity-occupancy slope could arise without changing the species' metapopulation parameters-importantly, without changing the dependence of colonization upon connectivity. We found that, for a range of landscape scenarios, successional simulations always produced a lower connectivity-occupancy slope than comparable simulations with static patches, whether compared like-for-like or controlling for mean occupancy. We conclude that landscape-scale studies may often underestimate the importance of connectivity for species occurrence and persistence because habitat turnover can obscure the connectivity-occupancy relationship in commonly

  8. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players.

    PubMed

    Daneshfar, Amin; Gahreman, Daniel E; Koozehchian, Majid S; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team ( n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA ( r = -0.57, p ≤ 0.05) and RSM ( r = -0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test ( r = -0.64, p ≤ 0.01) and in RSM test ( r = -0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT ( r = 0.58, p ≤ 0.01), WT ( r = 0.62, p ≤ 0.01), and TT ( r = 0 .65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM ( r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players.

  9. A large-scale deforestation experiment: Effects of patch area and isolation on Amazon birds

    USGS Publications Warehouse

    Ferraz, G.; Nichols, J.D.; Hines, J.E.; Stouffer, P.C.; Bierregaard, R.O.; Lovejoy, T.E.

    2007-01-01

    As compared with extensive contiguous areas, small isolated habitat patches lack many species. Some species disappear after isolation; others are rarely found in any small patch, regardless of isolation. We used a 13-year data set of bird captures from a large landscape-manipulation experiment in a Brazilian Amazon forest to model the extinction-colonization dynamics of 55 species and tested basic predictions of island biogeography and metapopulation theory. From our models, we derived two metrics of species vulnerability to changes in isolation and patch area. We found a strong effect of area and a variable effect of isolation on the predicted patch occupancy by birds.

  10. Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects.

    PubMed

    Cutajar, Marica; Clayden, Jonathan D; Clark, Christopher A; Gordon, Isky

    2011-12-01

    This study assessed test-retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Seven healthy volunteers (age range, 19-31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR=730 ms, TE=73 ms and 2 b-values (0 and 400 s mm(-2)). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Statistical analyses of both short- and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  11. Group-living herbivores weigh up food availability and dominance status when making patch-joining decisions.

    PubMed

    Stears, Keenan; Kerley, Graham I H; Shrader, Adrian M

    2014-01-01

    Two key factors that influence the foraging behaviour of group-living herbivores are food availability and individual dominance status. Yet, how the combination of these factors influences the patch-joining decisions of individuals foraging within groups has scarcely been explored. To address this, we focused on the patch-joining decisions of group-living domestic goats (Capra hircus). When individuals were tested against the top four ranked goats of the herd, we found that at patches with low food availability they avoided these dominant patch-holders and only joined subordinates (i.e. costs outweighed benefits). However, as the amount of food increased, the avoidance of the top ranked individuals declined. Specifically, goats shifted and joined the patch of an individual one dominance rank higher than the previous dominant patch holder when the initial quantity of food in the new patch was twice that of the lower ranking individual's patch (i.e. benefits outweighed costs). In contrast, when individuals chose between patches held by dominant goats, other than the top four ranked goats, and subordinate individuals, we found that they equally joined the dominant and subordinate patch-holders. This joining was irrespective of the dominance gap, absolute rank of the dominant patch-holder, sex or food availability (i.e. benefits outweighed costs). Ultimately, our results highlight that herbivores weigh up the costs and benefits of both food availability and patch-holder dominance status when making patch-joining decisions. Furthermore, as the initial quantity of food increases, food availability becomes more important than dominance with regard to influencing patch-joining decisions.

  12. ICAO helicopter noise measurement repeatability program : U.S. test report, Bell 206L-1, noise measurement flight test

    DOT National Transportation Integrated Search

    1985-09-30

    This document reports the findings of the U.S. test team's participation in the Helicopter Noise Measurement Repeatability Program (HNMRP) conducted under the direction of the International Civil Aviation Organization's (ICAO) Committee on Aviation E...

  13. Rapid establishment of a regular distribution of adult tropical Drosophila parasitoids in a multi-patch environment by patch defence behaviour.

    PubMed

    de Jong, Peter W; Hemerik, Lia; Gort, Gerrit; van Alphen, Jacques J M

    2011-01-01

    Females of the larval parasitoid of Drosophila, Asobara citri, from sub-Saharan Africa, defend patches with hosts by fighting and chasing conspecific females upon encounter. Females of the closely related, palearctic species Asobara tabida do not defend patches and often search simultaneously in the same patch. The effect of patch defence by A. citri females on their distribution in a multi-patch environment was investigated, and their distributions were compared with those of A. tabida. For both species 20 females were released from two release-points in replicate experiments. Females of A. citri quickly reached a regular distribution across 16 patches, with a small variance/mean ratio per patch. Conversely, A. tabida females initially showed a clumped distribution, and after gradual dispersion, a more Poisson-like distribution across patches resulted (variance/mean ratio was closer to 1 and higher than for A. citri). The dispersion of A. tabida was most probably an effect of exploitation: these parasitoids increasingly made shorter visits to already exploited patches. We briefly discuss hypotheses on the adaptive significance of patch defence behaviour or its absence in the light of differences in the natural history of both parasitoid species, notably the spatial distribution of their hosts.

  14. Mechanical compression insults induce nanoscale changes of membrane-skeleton arrangement which could cause apoptosis and necrosis in dorsal root ganglion neurons.

    PubMed

    Quan, Xin; Guo, Kai; Wang, Yuqing; Huang, Liangliang; Chen, Beiyu; Ye, Zhengxu; Luo, Zhuojing

    2014-01-01

    In a primary spinal cord injury, the amount of mechanical compression insult that the neurons experience is one of the most critical factors in determining the extent of the injury. The ultrastructural changes that neurons undergo when subjected to mechanical compression are largely unknown. In the present study, using a compression-driven instrument that can simulate mechanical compression insult, we applied mechanical compression stimulation at 0.3, 0.5, and 0.7 MPa to dorsal root ganglion (DRG) neurons for 10 min. Combined with atomic force microscopy, we investigated nanoscale changes in the membrane-skeleton, cytoskeleton alterations, and apoptosis induced by mechanical compression injury. The results indicated that mechanical compression injury leads to rearrangement of the membrane-skeleton compared with the control group. In addition, mechanical compression stimulation induced apoptosis and necrosis and also changed the distribution of the cytoskeleton in DRG neurons. Thus, the membrane-skeleton may play an important role in the response to mechanical insults in DRG neurons. Moreover, sudden insults caused by high mechanical compression, which is most likely conducted by the membrane-skeleton, may induce necrosis, apoptosis, and cytoskeletal alterations.

  15. Effect of oxidative insult on young and adult cardiac muscle cells in vitro.

    PubMed

    Nag, A C; Sreepathi, P; Lee, M L; Reddan, J R

    1996-01-01

    The effect of hydrogen peroxide on cultured neonatal and adult cardiac myocytes was investigated. On neonatal cardiac myocytes the effect was very pronounced at a low concentration (0.03 mM), whereas the adult cardiac myocytes were resistant to the same concentration of H2O2. Dividing neonatal cardiac myocytes were more susceptible to H2O2 insult than the non-dividing adult cardiac myocytes. At a concentration of 0.1 mM H2O2, the neonatal cardiac myocytes were significantly damaged compared with the adult cardiac myocytes. Cardiac muscle cells from neonatal and adult hearts at high density culture were more tolerant to the oxidative insult by H2O2 than cells in low density culture. The damaging effect of H2O2 was very selective on F-actin in neonatal and adult cardiac muscle cells. The effect of H2O2 on myosin, titin, alpha-actinin, desmin or tubulin was not pronounced. Microscopical studies suggested a more marked protection by catalase than by glutathione reductase in the neonatal cells.

  16. Patch-testing for the management of hypersensitivity reactions to second-line anti-tuberculosis drugs: a case report.

    PubMed

    Khan, Samsuddin; Andries, Aristomo; Pherwani, Asha; Saranchuk, Peter; Isaakidis, Petros

    2014-08-15

    The second-line anti-tuberculosis drugs used in the treatment of multidrug-resistant tuberculosis often cause adverse events, especially in patients co-infected with the human immunodeficiency virus. Severe hypersensitivity reactions due to these drugs are rare and there is little published experience to guide their management. A 17-year old Indian female multidrug-resistant tuberculosis patient co-infected with human immunodeficiency virus developed a hypersensitivity reaction after starting second-line anti-tuberculosis treatment in Mumbai, India. The patient was being treated with kanamycin, moxifloxacin, para-aminosalicylic acid, cycloserine, clofazimine, and amoxicillin-clavulanic acid. Twenty-four hours later, the patient developed generalized urticaria, morbilliform rash and fever. All drugs were suspended and the patient was hospitalised for acute management. Skin patch-testing was used to identify drugs that potentially caused the hypersensitivity reaction; results showed a strong reaction to clofazimine, moderate reaction to kanamycin and mild reaction to cycloserine. An interim second-line anti-tuberculosis regimen was prescribed; cycloserine and kanamycin were then re-challenged one-by-one using incremental dosing, an approach that allowed clinicians to re-introduce these drugs promptly and safely. The patient is currently doing well. This is the first case-report of a multidrug-resistant tuberculosis patient co-infected with the human immunodeficiency virus with hypersensitivity reaction to multiple second-line anti-tuberculosis drugs. Skin patch-testing and controlled re-challenge can be a useful management strategy in such patients. There is an urgent need for second-line anti-tuberculosis regimens that are more effective, safe and better tolerated.

  17. Effect of appreciation for Indigenous cultures and exposure to racial insults on alcohol and drug use initiation among multiethnic Argentinean youth.

    PubMed

    Alderete, Ethel; Gregorich, Steven E; Monteban, Madalena; Kaplan, Celia P; Mejia, Raul; Livaudais-Toman, Jennifer; Pérez-Stable, Eliseo J

    2016-04-01

    This study evaluated the effect of factors reflecting appreciation of Indigenous culture and racial insults on alcohol and drug use initiation among multi-ethnic youth in Jujuy, Argentina. Students were surveyed from 27 secondary schools that were randomly selected to represent the province. A total of 3040 eligible students in 10th grade, age 14 to 18years were surveyed in 2006 and 2660 of these same students completed surveys in 11th grade in 2007. Multivariate logistic regression models assessed the effect of appreciation for Indigenous cultures and reported exposure to racial insults in 10th grade on incident current alcohol drinking in previous 30days, binge drinking (≥5 drinks at one sitting), and lifetime drug use (marijuana, inhalants or cocaine) in 11th grade among students not reporting these behaviors in 2006. In 2006, 63% of respondents reported high appreciation for Indigenous cultures and 39% had ever experienced racial insults. In 2007, incident current drinking was 24.4%, binge drinking 14.8%, and any drug use initiation was 4.1%. Exposure to racial insults increased the likelihood of binge drinking (OR=1.6; 95% CI 1.2-2.1) but was not significant for any drug use. Appreciation for Indigenous cultures reduced the risk of any drug use initiation (OR=0.5, 95% CI 0.3-0.7) but had no effect for alcohol drinking outcomes. These effects were independent of Indigenous ethnicity. Enhancing appreciation for Indigenous cultures and decreasing racial insults are achievable goals that can be incorporated into programs to prevent youth substance use. Published by Elsevier Inc.

  18. Constraints and consequences of the emergence of amino acid repeats in eukaryotic proteins.

    PubMed

    Chavali, Sreenivas; Chavali, Pavithra L; Chalancon, Guilhem; de Groot, Natalia Sanchez; Gemayel, Rita; Latysheva, Natasha S; Ing-Simmons, Elizabeth; Verstrepen, Kevin J; Balaji, Santhanam; Babu, M Madan

    2017-09-01

    Proteins with amino acid homorepeats have the potential to be detrimental to cells and are often associated with human diseases. Why, then, are homorepeats prevalent in eukaryotic proteomes? In yeast, homorepeats are enriched in proteins that are essential and pleiotropic and that buffer environmental insults. The presence of homorepeats increases the functional versatility of proteins by mediating protein interactions and facilitating spatial organization in a repeat-dependent manner. During evolution, homorepeats are preferentially retained in proteins with stringent proteostasis, which might minimize repeat-associated detrimental effects such as unregulated phase separation and protein aggregation. Their presence facilitates rapid protein divergence through accumulation of amino acid substitutions, which often affect linear motifs and post-translational-modification sites. These substitutions may result in rewiring protein interaction and signaling networks. Thus, homorepeats are distinct modules that are often retained in stringently regulated proteins. Their presence facilitates rapid exploration of the genotype-phenotype landscape of a population, thereby contributing to adaptation and fitness.

  19. PL-PatchSurfer: a novel molecular local surface-based method for exploring protein-ligand interactions.

    PubMed

    Hu, Bingjie; Zhu, Xiaolei; Monroe, Lyman; Bures, Mark G; Kihara, Daisuke

    2014-08-27

    Structure-based computational methods have been widely used in exploring protein-ligand interactions, including predicting the binding ligands of a given protein based on their structural complementarity. Compared to other protein and ligand representations, the advantages of a surface representation include reduced sensitivity to subtle changes in the pocket and ligand conformation and fast search speed. Here we developed a novel method named PL-PatchSurfer (Protein-Ligand PatchSurfer). PL-PatchSurfer represents the protein binding pocket and the ligand molecular surface as a combination of segmented surface patches. Each patch is characterized by its geometrical shape and the electrostatic potential, which are represented using the 3D Zernike descriptor (3DZD). We first tested PL-PatchSurfer on binding ligand prediction and found it outperformed the pocket-similarity based ligand prediction program. We then optimized the search algorithm of PL-PatchSurfer using the PDBbind dataset. Finally, we explored the utility of applying PL-PatchSurfer to a larger and more diverse dataset and showed that PL-PatchSurfer was able to provide a high early enrichment for most of the targets. To the best of our knowledge, PL-PatchSurfer is the first surface patch-based method that treats ligand complementarity at protein binding sites. We believe that using a surface patch approach to better understand protein-ligand interactions has the potential to significantly enhance the design of new ligands for a wide array of drug-targets.

  20. PL-PatchSurfer: A Novel Molecular Local Surface-Based Method for Exploring Protein-Ligand Interactions

    PubMed Central

    Hu, Bingjie; Zhu, Xiaolei; Monroe, Lyman; Bures, Mark G.; Kihara, Daisuke

    2014-01-01

    Structure-based computational methods have been widely used in exploring protein-ligand interactions, including predicting the binding ligands of a given protein based on their structural complementarity. Compared to other protein and ligand representations, the advantages of a surface representation include reduced sensitivity to subtle changes in the pocket and ligand conformation and fast search speed. Here we developed a novel method named PL-PatchSurfer (Protein-Ligand PatchSurfer). PL-PatchSurfer represents the protein binding pocket and the ligand molecular surface as a combination of segmented surface patches. Each patch is characterized by its geometrical shape and the electrostatic potential, which are represented using the 3D Zernike descriptor (3DZD). We first tested PL-PatchSurfer on binding ligand prediction and found it outperformed the pocket-similarity based ligand prediction program. We then optimized the search algorithm of PL-PatchSurfer using the PDBbind dataset. Finally, we explored the utility of applying PL-PatchSurfer to a larger and more diverse dataset and showed that PL-PatchSurfer was able to provide a high early enrichment for most of the targets. To the best of our knowledge, PL-PatchSurfer is the first surface patch-based method that treats ligand complementarity at protein binding sites. We believe that using a surface patch approach to better understand protein-ligand interactions has the potential to significantly enhance the design of new ligands for a wide array of drug-targets. PMID:25167137

  1. Preliminary evaluation of a micro-based repeated measures testing system

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Wilkes, Robert L.; Lane, Norman E.

    1985-01-01

    A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

  2. BDNF heightens the sensitivity of motor neurons to excitotoxic insults through activation of TrkB

    NASA Technical Reports Server (NTRS)

    Hu, Peter; Kalb, Robert G.; Walton, K. D. (Principal Investigator)

    2003-01-01

    The survival promoting and neuroprotective actions of brain-derived neurotrophic factor (BDNF) are well known but under certain circumstances this growth factor can also exacerbate excitotoxic insults to neurons. Prior exploration of the receptor through which BDNF exerts this action on motor neurons deflects attention away from p75. Here we investigated the possibility that BDNF acts through the receptor tyrosine kinase, TrkB, to confer on motor neurons sensitivity to excitotoxic challenge. We blocked BDNF activation of TrkB using a dominant negative TrkB mutant or a TrkB function blocking antibody, and found that this protected motor neurons against excitotoxic insult in cultures of mixed spinal cord neurons. Addition of a function blocking antibody to BDNF to mixed spinal cord neuron cultures is also neuroprotective indicating that endogenously produced BDNF participates in vulnerability to excitotoxicity. We next examined the intracellular signaling cascades that are engaged upon TrkB activation. Previously we found that inhibition of the phosphatidylinositide-3'-kinase (PI3'K) pathway blocks BDNF-induced excitotoxic sensitivity. Here we show that expression of a constitutively active catalytic subunit of PI3'K, p110, confers excitotoxic sensitivity (ES) upon motor neurons not incubated with BDNF. Parallel studies with purified motor neurons confirm that these events are likely to be occuring specifically within motor neurons. The abrogation of BDNF's capacity to accentuate excitotoxic insults may make it a more attractive neuroprotective agent.

  3. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    PubMed

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Formulation, in vitro and in vivo evaluation of transdermal patches containing risperidone.

    PubMed

    Aggarwal, Geeta; Dhawan, Sanju; Hari Kumar, S L

    2013-01-01

    The efficacy of oral risperidone treatment in prevention of schizophrenia is well known. However, oral side effects and patient compliance is always a problem for schizophrenics. In this study, risperidone was formulated into matrix transdermal patches to overcome these problems. The formulation factors for such patches, including eudragit RL 100 and eudragit RS 100 as matrix forming polymers, olive oil, groundnut oil and jojoba oil in different concentrations as enhancers and amount of drug loaded were investigated. The transdermal patches containing risperidone were prepared by solvent casting method and characterized for physicochemical and in vitro permeation studies through excised rat skin. Among the tested preparations, formulations with 20% risperidone, 3:2 ERL 100 and ERS 100 as polymers, mixture of olive oil and jojoba oil as enhancer, exhibited greatest cumulative amount of drug permeated (1.87 ± 0.09 mg/cm(2)) in 72 h, so batch ROJ was concluded as optimized formulation and assessed for pharmacokinetic, pharmacodynamic and skin irritation potential. The pharmacokinetic characteristics of the optimized risperidone patch were determined using rabbits, while orally administered risperidone in solution was used for comparison. The calculated relative bioavailability of risperidone transdermal patch was 115.20% with prolonged release of drug. Neuroleptic efficacy of transdermal formulation was assessed by rota-rod and grip test in comparison with control and marketed oral formulations with no skin irritation. This suggests the transdermal application of risperidone holds promise for improved bioavailability and better management of schizophrenia in long-term basis.

  5. Polysensitivity in delayed cutaneous adverse drug reactions to macrolides, clindamycin, and pristinamycin: clinical history and patch testing.

    PubMed

    El Khoury, M; Assier, H; Gener, G; Paul, M; Haddad, C; Chosidow, O; Wolkenstein, P; Ingen-Housz-Oro, S

    2018-05-10

    Although they have different biochemical structures, macrolides, lincosamides (including clindamycin) and streptogramins (including pristinamycin) share a similar mechanism of action on Gram-positive bacteria and are grouped into the MLS family. 1 Cross-allergies induced by drugs of similar mechanism of action but different chemical structure (polysensitivity) are poorly described. Our objectives were to investigate the possibility of polysensitivity among MLS antibiotics, and to compare the value of patch tests (PTs) in MLS-induced delayed-cutaneous adverse drug reactions (D-CADRs). This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Development of mucoadhesive patches for buccal administration of carvedilol.

    PubMed

    Vishnu, Y Vamshi; Chandrasekhar, K; Ramesh, G; Rao, Y Madhusudan

    2007-01-01

    A buccal patch for systemic administration of carvedilol in the oral cavity has been developed using two different mucoadhesive polymers. The formulations were tested for in vitro drug permeation studies, buccal absorption test, in vitro release studies, moisture absorption studies and in vitro bioadhesion studies. The physicochemical interactions between carvedilol and polymers were investigated by Fourier transform infrared (FTIR) Spectroscopy. According to FTIR the drug did not show any evidence of an interaction with the polymers used and was present in an unchanged state. XRD studies reveal that the drug is in crystalline state in the polymer matrix. The results indicate that suitable bioadhesive buccal patches with desired permeability could be prepared. Bioavailability studies in healthy pigs reveal that carvedilol has got good buccal absorption. The bioavailability of carvedilol from buccal patches has increased 2.29 folds when compared to that of oral solution. The formulation AC5 (HPMC E 15) shows 84.85 + 0.089% release and 38.69 + 6.61% permeated through porcine buccal membrane in 4 hr. The basic pharmacokinetic parameters like the C(max), T(max) and AUC(total) were calculated and showed statistically significant difference (P<0.05) when given by buccal route compared to that of oral solution.

  7. Test-to-Test Repeatability of Results From a Subsonic Wing-Body Configuration in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Mineck, Raymond E.; Pendergraft, Odis C., Jr.

    2000-01-01

    Results from three wind tunnel tests in the National Transonic Facility of a model of an advanced-technology, subsonic-transport wing-body configuration have been analyzed to assess the test-to-test repeatability of several aerodynamic parameters. The scatter, as measured by the prediction interval, in the longitudinal force and moment coefficients increases as the Mach number increases. Residual errors with and without the ESP tubes installed suggest a bias leading to lower drag with the tubes installed. Residual errors as well as average values of the longitudinal force and moment coefficients show that there are small bias errors between the different tests.

  8. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release.

    PubMed

    Summer, Burkhard; Fink, Ulrich; Zeller, Richard; Rueff, Franziska; Maier, Sonja; Roider, Gabriele; Thomas, Peter

    2007-07-01

    Nickel, chromium, and cobalt released from stainless steel and CoCrMo alloys have been postulated to trigger hypersensitivity reactions. The objective of this study was to assess the ion release from a CoCrMo alloy and stainless steel in vitro and the cutaneous reactivity to it by patch test. 52 metal-allergic patients and 48 non-allergic controls were patch tested to stainless steel and CoCrMo discs. In addition, using atomic absorption spectrometry, the release of nickel, cobalt, and chromium from both materials was assessed upon 2-day exposure to distilled water, artificial sweat (AS), and cell culture medium. There was low nickel ion release from stainless steel (0.3-0.46 microg/cm(2)/2 days) and CoCrMo discs (up to 0.33 microg/cm(2)/2 days) into the different elution media. Chromium release from the 2 materials was also very low (0.06-0.38 microg/cm(2)/2 days from stainless steel and 0.52-1.36 microg/cm(2)/2 days from CoCrMo alloy). In contrast, AS led to abundant cobalt release (maximally 18.94 microg/cm(2)/2 days) from the CoCrMo discs, with concomitant eczematous reaction upon patch testing: 0 of the 52 metal-allergic patients reacted to stainless steel discs and 5 of the 52 patients to CoCrMo discs (all 5 patients were cobalt allergic and 3 also nickel and chromium allergic). None of the controls reacted to the discs. Apart from nickel being a focus of allergological research, our results point to the possibly underestimated association of cobalt release and potential hyperreactivity to CoCrMo alloy.

  9. Concrete patching guide : final report.

    DOT National Transportation Integrated Search

    2003-09-01

    Maintenance personnel often select a material for patching concrete based on what they have used in the past. However, each patching job has particular demands, which may be different from what was required in past applications. Also, the list of ava...

  10. Research notes : concrete patching guide.

    DOT National Transportation Integrated Search

    2004-05-01

    Maintenance personnel often select a material for patching concrete based on what they have used in the past. However, each patching job has particular demands, which may be different from what was required in past applications. Also, the list of ava...

  11. Robust Observation Detection for Single Object Tracking: Deterministic and Probabilistic Patch-Based Approaches

    PubMed Central

    Zulkifley, Mohd Asyraf; Rawlinson, David; Moran, Bill

    2012-01-01

    In video analytics, robust observation detection is very important as the content of the videos varies a lot, especially for tracking implementation. Contrary to the image processing field, the problems of blurring, moderate deformation, low illumination surroundings, illumination change and homogenous texture are normally encountered in video analytics. Patch-Based Observation Detection (PBOD) is developed to improve detection robustness to complex scenes by fusing both feature- and template-based recognition methods. While we believe that feature-based detectors are more distinctive, however, for finding the matching between the frames are best achieved by a collection of points as in template-based detectors. Two methods of PBOD—the deterministic and probabilistic approaches—have been tested to find the best mode of detection. Both algorithms start by building comparison vectors at each detected points of interest. The vectors are matched to build candidate patches based on their respective coordination. For the deterministic method, patch matching is done in 2-level test where threshold-based position and size smoothing are applied to the patch with the highest correlation value. For the second approach, patch matching is done probabilistically by modelling the histograms of the patches by Poisson distributions for both RGB and HSV colour models. Then, maximum likelihood is applied for position smoothing while a Bayesian approach is applied for size smoothing. The result showed that probabilistic PBOD outperforms the deterministic approach with average distance error of 10.03% compared with 21.03%. This algorithm is best implemented as a complement to other simpler detection methods due to heavy processing requirement. PMID:23202226

  12. Updated WORF patch

    NASA Image and Video Library

    2012-08-16

    This patch represents the essential elements associated with pressurized Earth science research aboard the International Space Station. At the top of the patch Klingon script spells out the acronym WORF making reference to the famed Star Trek character of the same name. In doing so it attests to the foresight, honor, integrity, and persistence of all those who made the WORF possible. To the right of the Klingon script is a single four pointed star in the form of a cross to honor the late Dr. Jack Estes and Dr. Dave Amsbury, the individuals most responsible for seeing to it that an optical quality, Earth science research window was added to the United States laboratory module, Destiny. The "flying eyeball" represents the ability of the ISS to allow scientists and astronauts to make and record continuous observations of natural and manmade processes on the surface of the Earth. The Destiny laboratory is depicted on the right of the patch above the Flag of the United States of America and highlights the position of the nadir looking, optical quality, science window in the module. The light emanating from the window from the lighted interior of the module appropriately illuminates the National Ensign for display during both day and night time. In the center of the patch, below the flying eyeball is a graphic representation of the WORF rack. A science instrument is mounted on the WORF payload shelf and is recording data of the Earth's surface through the nadir looking, science window over which the WORF rack is mounted. An astronaut represented by Mario Runco Jr., a designer, developer, and manager of the WORF and depicted as Star Trek's Mr. Spock, is to the left of the WORF rack and is shown in his flight suit with his STS-44 mission patch operating an imaging instrument, emphasizing the importance of astronaut participation to achieve the maximum scientific return from orbital research.

  13. Two decades of occupational (meth)acrylate patch test results and focus on isobornyl acrylate.

    PubMed

    Christoffers, Wietske A; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise A

    2013-08-01

    Acrylates constitute an important cause of occupational contact dermatitis. Isobornyl acrylate sensitization has been reported in only 2 cases. We encountered an industrial process operator with occupational contact dermatitis caused by isobornyl acrylate. (i) To investigate whether it is relevant to add isobornyl acrylate to the (meth)acrylate test series. (ii) To report patients with (meth)acrylate contact allergy at an occupational dermatology clinic. Our patch test database was screened for positive reactions to (meth)acrylates between 1993 and 2012. A selected group of 14 patients was tested with an isobornyl acrylate dilution series: 0.3%, 0.1%, 0.033%, and 0.01%. Readings were performed on D2, D3, and D7. One hundred and fifty-one patients were tested with our (meth)acrylate series; 24 had positive reactions. Most positive reactions were to 2-hydroxypropyl acrylate, 2-hydroxyethyl acrylate, 2-hydroxypropyl methacrylate, and diethyleneglycol diacrylate. Hypothetical screening with 2-hydroxypropyl acrylate, ethyleneglycol dimethacrylate, ethoxylated bisphenol A glycol dimethacrylate and trimethylolpropane triacrylate identified 91.7% of the 24 patients. No positive reactions were observed in 14 acrylate-positive patients tested with the isobornyl acrylate dilution series. The 0.3% isobornyl acrylate concentration induced irritant reactions in 3 patients. We report a rare case of allergic contact dermatitis caused by isobornyl acrylate. However, this study provides insufficient support for isobornyl acrylate to be added to a (meth)acrylate series. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Cell-Detection Technique for Automated Patch Clamping

    NASA Technical Reports Server (NTRS)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  15. Detailed spatiotemporal evolution of microseismicity and repeating earthquakes following the 2012 Mw 7.6 Nicoya earthquake

    NASA Astrophysics Data System (ADS)

    Yao, Dongdong; Walter, Jacob I.; Meng, Xiaofeng; Hobbs, Tiegan E.; Peng, Zhigang; Newman, Andrew V.; Schwartz, Susan Y.; Protti, Marino

    2017-01-01

    We apply a waveform matching technique to obtain a detailed earthquake catalog around the rupture zone of the 5 September 2012 moment magnitude 7.6 Nicoya earthquake, with emphasis on its aftershock sequence. Starting from a preliminary catalog, we relocate 7900 events using TomoDD to better quantify their spatiotemporal behavior. Relocated aftershocks are mostly clustered in two groups. The first is immediately above the major coseismic slip patch, partially overlapping with shallow afterslip. The second one is 50 km SE to the main shock nucleation point and near the terminus of coseismic rupture, in a zone that exhibited little resolvable afterslip. Using the relocated events as templates, we scan through the continuous recording from 29 June 2012 to 30 December 2012, detecting approximately 17 times more than template events. We find 190 aftershocks in the first half hour following the main shock, mostly along the plate interface. Later events become more scattered in location, showing moderate expansion in both along-trench and downdip directions. From the detected catalog we identify 53 repeating aftershock clusters with mean cross-correlation values larger than 0.9, and indistinguishably intracluster event locations, suggesting slip on the same fault patch. Most repeating clusters occurred within the first major aftershock group. Very few repeating clusters were found in the aftershock grouping along the southern edge of the Peninsula, which is not associated with substantial afterslip. Our observations suggest that loading from nearby afterslip along the plate interface drives spatiotemporal evolution of aftershocks just above the main shock rupture patch, while aftershocks in the SE group are to the SE of the observed updip afterslip and poorly constrained.

  16. Parenting, attention and externalizing problems: testing mediation longitudinally, repeatedly and reciprocally.

    PubMed

    Belsky, Jay; Pasco Fearon, R M; Bell, Brian

    2007-12-01

    Building on prior work, this paper tests, longitudinally and repeatedly, the proposition that attentional control processes mediate the effect of earlier parenting on later externalizing problems. Repeated independent measurements of all three constructs--observed parenting, computer-tested attentional control and adult-reported externalizing problems--were subjected to structural equation modeling using data from the large-scale American study of child care and youth development. Structural equation modeling indicated (a) that greater maternal sensitivity at two different ages (54 months, approximately 6 years) predicted better attentional control on the Continuous Performance Test (CPT) of attention regulation two later ages ( approximately 6/9 years); (2) that better attentional control at three different ages (54 months, approximately 6/9 years) predicted less teacher-reported externalizing problems at three later ages ( approximately 6/8/10 years); and (3) that attentional control partially mediated the effect of parenting on externalizing problems at two different lags (i.e., 54 months--> approximately 6 years--> approximately 8 years; approximately 6 years--> approximately 9 years--> approximately 10 years), though somewhat more strongly for the first. Additionally, (4) some evidence of reciprocal effects of attentional processes on parenting emerged (54 months--> approximately 6 years; approximately 6 years--> approximately 8 years), but not of problem behavior on attention. Because attention control partially mediates the effects of parenting on externalizing problems, intervention efforts could target both parenting and attentional processes.

  17. 24 and 48 h allergen exposure in patch testing. Comparative study with 11 common contact allergens and NiCl2.

    PubMed

    Kalimo, K; Lammintausta, K

    1984-01-01

    Patch test reactions to 11 common contact allergens were studied after 24 h and 48 h occlusion with Finn Chambers in 390 patients. Concordant allergic results were found in 96 cases (74%). In 22 patients (17%), the reaction was positive only after 48 h and in 11 cases (8.5%) only after 24 h exposure. Most of the discordant reactions were to nickel, cobalt, neomycin, formaldehyde and perfume mix. Irritant reactions were found in 55 cases, the majority occurring after 48 h occlusion. Nickel chloride tested in parallel with 48 h exposure lead to more positive allergic and toxic reactions than nickel sulphate.

  18. Global Patch Matching

    NASA Astrophysics Data System (ADS)

    Huang, X.; Hu, K.; Ling, X.; Zhang, Y.; Lu, Z.; Zhou, G.

    2017-09-01

    This paper introduces a novel global patch matching method that focuses on how to remove fronto-parallel bias and obtain continuous smooth surfaces with assuming that the scenes covered by stereos are piecewise continuous. Firstly, simple linear iterative cluster method (SLIC) is used to segment the base image into a series of patches. Then, a global energy function, which consists of a data term and a smoothness term, is built on the patches. The data term is the second-order Taylor expansion of correlation coefficients, and the smoothness term is built by combing connectivity constraints and the coplanarity constraints are combined to construct the smoothness term. Finally, the global energy function can be built by combining the data term and the smoothness term. We rewrite the global energy function in a quadratic matrix function, and use least square methods to obtain the optimal solution. Experiments on Adirondack stereo and Motorcycle stereo of Middlebury benchmark show that the proposed method can remove fronto-parallel bias effectively, and produce continuous smooth surfaces.

  19. Human epidermal growth factor receptor 2 testing in invasive breast cancer: should histological grade, type and oestrogen receptor status influence the decision to repeat testing?

    PubMed

    Rakha, Emad A; Pigera, Marian; Shin, Sandra J; D'Alfonso, Timothy; Ellis, Ian O; Lee, Andrew H S

    2016-07-01

    The recent American Society of Clinical Oncology/College of American Pathologists guidelines for human epidermal growth factor receptor 2 (HER2) testing in breast cancer recommend repeat testing based on tumour grade, tumour type, and hormone receptor status. The aim of this study was to test the value of these criteria. HER2 status was concordant in the core biopsies and excision specimens in 392 of 400 invasive carcinomas. The major reasons for discordance were amplification around the cut-off for positivity and tumour heterogeneity. Of 116 grade 3 carcinomas that were HER2-negative in the core biopsy, four were HER2-positive in the excision specimen. Three of these four either showed borderline negative amplification in the core biopsy or were heterogeneous. None of the 55 grade 1 carcinomas were HER2-positive. Review of repeat testing of HER2 in routine practice suggested that it may also be of value for multifocal tumours and if recommended by the person assessing the in-situ hybridization. Mandatory repeat HER2 testing of grade 3 HER2-negative carcinomas is not appropriate. This is particularly true if repeat testing is performed after borderline negative amplification in the core biopsy or in HER2-negative heterogeneous carcinomas. © 2015 John Wiley & Sons Ltd.

  20. Effect of Appreciation for Indigenous Cultures and Exposure to Racial Insults on Alcohol and Drug use Initiation among Multiethnic Argentinean Youth

    PubMed Central

    Alderete, Ethel; Gregorich, Steven E.; Monteban, Madalena; Kaplan, Celia P.; Mejia, Raul; Livaudais-Toman, Jennifer; Pérez-Stable, Eliseo J.

    2017-01-01

    This study evaluated the effect of factors reflecting appreciation of Indigenous culture and racial insults on alcohol and drug use initiation among multi-ethnic youth in Jujuy, Argentina. Students were surveyed from 27 secondary schools that were randomly selected to represent the province. A total of 3,040 eligible students in 10th grade, age 14 to 18 years were surveyed in 2006 and 2,660 of these same students completed surveys in 11th grade in 2007. Multivariate logistic regression models assessed the effect of appreciation for Indigenous cultures and reported exposure to racial insults in 10th grade on incident current alcohol drinking in previous 30 days, binge drinking (≥5 drinks at one sitting), and lifetime drug use (marijuana, inhalants or cocaine) in 11th grade among students not reporting these behaviors in 2006. In 2006, 63% of respondents reported high appreciation for Indigenous cultures and 39% had ever experienced racial insults. In 2007, incident current drinking was 24.4%, binge drinking 14.8%, and any drug use initiation was 4.1%. Exposure to racial insults increased the likelihood of binge drinking (OR=1.6; 95% CI 1.2–2.1) but was not significant for any drug use. Appreciation for Indigenous cultures reduced the risk of any drug use initiation (OR=0.5, 95% CI 0.3–0.7) but had no effect for alcohol drinking outcomes. These effects were independent of Indigenous ethnicity. Enhancing appreciation for Indigenous cultures and decreasing racial insults are achievable goals that can be incorporated into programs to prevent youth substance use. PMID:26763165

  1. Human motion energy harvesting using a piezoelectric MFC patch.

    PubMed

    Bassani, Giulia; Filippeschi, Alessandro; Ruffaldi, Emanuele

    2015-01-01

    The improvements in efficiency of electronic components and miniaturization is quickly pushing wearable devices. Kinetic human energy harvesting is a way to power these components reducing the need of batteries replacement since walking or running is how humans already expend much of their daily energy. This work explores the case of kinetic energy from bending of a piezoelectric patch. For assessing the quality of the system, a testing setup has been designed and controlled by means of knee joint recordings obtained from a large motion dataset. The promising result of the chosen patch is an output power of 2.6μW associated to a run activity.

  2. A procedure of landscape services assessment based on mosaics of patches and boundaries.

    PubMed

    Martín de Agar, Pilar; Ortega, Marta; de Pablo, Carlos L

    2016-09-15

    We develop a procedure for assessing the environmental value of landscape mosaics that simultaneously considers the values of land use patches and the values of the boundaries between them. These boundaries indicate the ecological interactions between the patches. A landscape mosaic is defined as a set of patches and the boundaries between them and corresponds to a spatial pattern of ecological interactions. The procedure is performed in two steps: (i) an environmental assessment of land use patches by means of a function that integrates values based on the goods and services the patches provide, and (ii) an environmental valuation of mosaics using a function that integrates the environmental values of their patches and the types and frequencies of the boundaries between them. This procedure allows us to measure how changes in land uses or in their spatial arrangement cause variations in the environmental value of landscape mosaics and therefore in that of the whole landscape. The procedure was tested in the Sierra Norte of Madrid (central Spain). The results show that the environmental values of the landscape depend not only on the land use patches but also on the values associated with the pattern of the boundaries within the mosaics. The results also highlight the importance of the boundaries between land use patches as determinants of the goods and services provided by the landscape. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players

    PubMed Central

    Daneshfar, Amin; Gahreman, Daniel E.; Koozehchian, Majid S.; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T.

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05) and RSM (r = −0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test (r = −0.64, p ≤ 0.01) and in RSM test (r = −0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01), WT (r = 0.62, p ≤ 0.01), and TT (r = 0.65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players. PMID:29670536

  4. The effects of patch shape and connectivity on nest site selection and reproductive success of the Indigo Bunting.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weldon, Aimee Jean

    2004-07-01

    Description – Ph.D Dissertation. North Carolina State University. Raleigh, North Carolina. 135 pp. Abatract - Habitat fragmentation and its associated effects have been blamed for the recent population declines of many Neotropical migratory bird species. Increased predation and parasitism resulting from edge-related effects have been implicated for poor nesting success in many studies, mostly of forest interior species. However, little attention has been devoted to disturbance-dependent birds. In this study, I examine how patch shape and connectivity in fragmented landscapes affects the reproductive success of disturbance-dependent bird species, specifically the Indigo Bunting (Passerina cyanea). I conducted my study in amore » landscape-scale experimental system of similar-area habitat patches that differed in connectivity and in shape. Shapes differed between edgy and rectangular forms, where edgy patches contained 50% more edge than rectangular patches. I tested whether edgy patches function as ecological traps for species with strong edge preferences, by leading them to select dangerous habitats. Indigo Buntings preferentially selected edgy patches over rectangular patches, but experienced significantly lower reproductive success in edgy patches early in the season. Although predation pressure intensified in rectangular patches late in the season, seasonal fecundity was still significantly lower in edgy patches, providing the first empirical evidence that edges can function as ecological traps for Indigo Buntings. A second objective of my study was to evaluate the efficacy of conservation corridors for disturbance-dependent bird species. Conservation corridors have become a popular strategy to preserve biodiversity and promote gene flow in fragmented landscapes, but corridors may also have negative consequences. I tested the hypothesis that corridors can increase nest predation risk in connected patches relative to unconnected patches. Nest predation rates

  5. The effectiveness of an adhesively bonded composite patch repair as applied to a transport aircraft lower wing skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruschau, J.J.; Coate, J.E.

    1996-12-31

    Specimens were machined from lower wing skin extrusions of a transport aircraft, precracked under fatigue loading, repaired with a boron/epoxy patch, and subsequently fatigue tested under simulated flight loading conditions to evaluate the effectiveness of an adhesively bonded repair patch. Testing was performed at RT and -54{degrees}C for two configurations: one with the crack running up the integral stiffener (riser), the other running down the riser towards the outer skin surface. Cracks were initiated from a single 6.35 mm diameter hole located in the riser portion of the 7075-T6 wing skin material. Ultrasonic inspections were performed during fatigue loading tomore » determine crack growth and damage underneath the patch. Limited results show the adhesively bonded patch was successful in stopping or greatly reducing any further crack growth. Under laboratory air conditions, no crack growth occurred following 30,000 equivalent flight hours, double the expected life of the patched structure. Similarly at -54{degrees}C, no crack growth was observed for a patched crack growing up the riser following 15,000 EFH. For the case of a crack growing down the riser at the lower test temperature, some crack growth was measured, though at a greatly reduced rate.« less

  6. An Active Patch Model for Real World Texture and Appearance Classification

    PubMed Central

    Mao, Junhua; Zhu, Jun; Yuille, Alan L.

    2014-01-01

    This paper addresses the task of natural texture and appearance classification. Our goal is to develop a simple and intuitive method that performs at state of the art on datasets ranging from homogeneous texture (e.g., material texture), to less homogeneous texture (e.g., the fur of animals), and to inhomogeneous texture (the appearance patterns of vehicles). Our method uses a bag-of-words model where the features are based on a dictionary of active patches. Active patches are raw intensity patches which can undergo spatial transformations (e.g., rotation and scaling) and adjust themselves to best match the image regions. The dictionary of active patches is required to be compact and representative, in the sense that we can use it to approximately reconstruct the images that we want to classify. We propose a probabilistic model to quantify the quality of image reconstruction and design a greedy learning algorithm to obtain the dictionary. We classify images using the occurrence frequency of the active patches. Feature extraction is fast (about 100 ms per image) using the GPU. The experimental results show that our method improves the state of the art on a challenging material texture benchmark dataset (KTH-TIPS2). To test our method on less homogeneous or inhomogeneous images, we construct two new datasets consisting of appearance image patches of animals and vehicles cropped from the PASCAL VOC dataset. Our method outperforms competing methods on these datasets. PMID:25531013

  7. Omnibus Tests for Interactions in Repeated Measures Designs with Dichotomous Dependent Variables.

    ERIC Educational Resources Information Center

    Serlin, Ronald C.; Marascuilo, Leonard A.

    When examining a repeated measures design with independent groups for a significant group by trial interaction, classical analysis of variance or multivariate procedures can be used if the assumptions underlying the tests are met. Neither procedure may be justified for designs with small sample sizes and dichotomous dependent variables. An omnibus…

  8. Repeated rat-forced swim test: reducing the number of animals to evaluate gradual effects of antidepressants.

    PubMed

    Mezadri, T J; Batista, G M; Portes, A C; Marino-Neto, J; Lino-de-Oliveira, C

    2011-02-15

    The forced swim test (FST) is a pre-clinical test to short and long term treatment with antidepressant drugs (ADT), which requires between-subject designs. Herein a modified protocol of the FST using within-subject design (repeated rat-FST) was evaluated. Male Wistar rats were submitted to 15 min of swimming (Day 1: pretest) followed by three subsequent 5 min-swimming tests one week apart (Day 2: test, Day 7: retest 1, Day 14: retest 2). To determine the temporal and factorial characteristics of the variables scored in the repeated rat-FST, the protocol was carried out in untreated animals (E1). To validate the method, daily injections of Fluoxetine (FLX, 2.5mg/kg, i.p.) or saline were given over a 2-week period (E2). Tests and retests have been videotaped for further register of the latency, frequency and duration of behaviors. Over retesting the latency to immobility decreased whereas duration of immobility tended to increase. Factorial analysis revealed that the test, the retest 1 as well as the retest 2 have variables suitable to detection of antidepressant-like effects of ADT. Compared to saline, FLX chronically administrated reduced duration of immobility whereas increased duration of swimming in retest 2. The data suggest that repeated rat-FST detected the gradual increase in the efficacy of low doses of FLX over time. Therefore, repeated rat-FST seemed suitable to detect short and long term effects of selective serotonin reuptake inhibitors, or other ADT, thus reducing the number of animals used in the screenings of this type of compounds. © 2010 Elsevier B.V. All rights reserved.

  9. PatchSurfers: Two methods for local molecular property-based binding ligand prediction.

    PubMed

    Shin, Woong-Hee; Bures, Mark Gregory; Kihara, Daisuke

    2016-01-15

    Protein function prediction is an active area of research in computational biology. Function prediction can help biologists make hypotheses for characterization of genes and help interpret biological assays, and thus is a productive area for collaboration between experimental and computational biologists. Among various function prediction methods, predicting binding ligand molecules for a target protein is an important class because ligand binding events for a protein are usually closely intertwined with the proteins' biological function, and also because predicted binding ligands can often be directly tested by biochemical assays. Binding ligand prediction methods can be classified into two types: those which are based on protein-protein (or pocket-pocket) comparison, and those that compare a target pocket directly to ligands. Recently, our group proposed two computational binding ligand prediction methods, Patch-Surfer, which is a pocket-pocket comparison method, and PL-PatchSurfer, which compares a pocket to ligand molecules. The two programs apply surface patch-based descriptions to calculate similarity or complementarity between molecules. A surface patch is characterized by physicochemical properties such as shape, hydrophobicity, and electrostatic potentials. These properties on the surface are represented using three-dimensional Zernike descriptors (3DZD), which are based on a series expansion of a 3 dimensional function. Utilizing 3DZD for describing the physicochemical properties has two main advantages: (1) rotational invariance and (2) fast comparison. Here, we introduce Patch-Surfer and PL-PatchSurfer with an emphasis on PL-PatchSurfer, which is more recently developed. Illustrative examples of PL-PatchSurfer performance on binding ligand prediction as well as virtual drug screening are also provided. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Reward modulation of contextual cueing: Repeated context overshadows repeated target location.

    PubMed

    Sharifian, Fariba; Contier, Oliver; Preuschhof, Claudia; Pollmann, Stefan

    2017-10-01

    Contextual cueing can be enhanced by reward. However, there is a debate if reward is associated with the repeated target-distractor configurations or with the repeated target locations that occur in both repeated and new displays. Based on neuroimaging evidence, we hypothesized that reward becomes associated with the target location only in new displays, but not in repeated displays, where the repeated target location is overshadowed by the more salient repeated target-distractor configuration. To test this hypothesis, we varied the reward value associated with the same target location in repeated and new displays. The results confirmed the overshadowing hypothesis in that search facilitation in repeated target-distractor configurations was modulated by the variable value associated with the target location. This effect was observed mainly in early learning.

  11. Exploration of ethyl anthranilate-loaded monolithic matrix-type prophylactic polymeric patch.

    PubMed

    Islam, Johirul; Zaman, Kamaruz; Chakrabarti, Srijita; Bora, Nilutpal Sharma; Pathak, Manash Pratim; Mandal, Santa; Junejo, Julfikar Ali; Chattopadhyay, Pronobesh

    2017-10-01

    Compromised stability of pharmaceutical formulations loaded with volatiles is a serious problem associated with devices designed to deliver volatile compounds. The present study has been focused to evaluate the stability potential of matrix-type polymeric patches composed of volatile ethyl anthranilate for prophylaxis against vector-borne diseases. Ethyl anthranilate-loaded matrix-type polymeric patches were fabricated by solvent evaporation method on an impermeable backing membrane and attached to temporary release liners. Stability testing of the polymeric patches was performed as per the International Conference on Harmonization (ICH) guidelines for 6 months under accelerated conditions. In addition, the quantification of residual solvents was also performed as per the ICH guidelines. After conducting the stability studies for 6 months, the optimized patches showed the best possible results with respect to uniformity of drug content, physical appearance, and other analytical parameters. Furthermore, the amount of residual solvent was found well below the accepted limit. Thus, the present report outlined the analytical parameters to be evaluated to ensure the stability of a certain devices consisting of volatile compounds. Copyright © 2016. Published by Elsevier B.V.

  12. Relative abundance of mesopredators and size of oak patches in the cross-timbers ecoregion

    USGS Publications Warehouse

    Disney, M.R.; Hellgren, E.C.; Davis, C.A.; Leslie, David M.; Engle, David M.

    2008-01-01

    Mesopredators (e.g., raccoon Procyon lotor, Virginia opossum Didelphis virginiana, striped skunk Mephitis mephitis) have received considerable attention because of links to population declines in birds via increased nest predation, especially in landscapes fragmented by anthropogenic forces. Relationships of abundance of mesopredators to size of habitat patches have received less attention than relationships to other metrics of fragmentation, particularly edge characteristics. We tested the hypothesis that relative abundance of mesopredators (e.g., raccoons and Virginia opossums) was related negatively to size of forest patch. We delineated 15 patches of oak (Quercus) forest ranging from 0.2 to 55.3 ha within a grassland-woodland mosaic in the cross-timbers ecoregion of Oklahoma. Scent stations and live traps within these patches were used to index relative abundance of mesopredators in summers 2003 and 2004. Both indices of relative abundance were related weakly and negatively to area of forest patch. However, rate of capture and visitation to scent station were not correlated consistently throughout the study. Our results suggested that the two methods to index abundance provided separate information on functional and numerical responses to size of patch. Our evidence that mesopredators within the cross timbers were more likely to be in smaller patches of oak forest may have implications to success of avian nesting in these patches.

  13. Micromachined patch-clamp apparatus

    DOEpatents

    Okandan, Murat

    2012-12-04

    A micromachined patch-clamp apparatus is disclosed for holding one or more cells and providing electrical, chemical, or mechanical stimulation to the cells during analysis with the patch-clamp technique for studying ion channels in cell membranes. The apparatus formed on a silicon substrate utilizes a lower chamber formed from silicon nitride using surface micromachining and an upper chamber formed from a molded polymer material. An opening in a common wall between the chambers is used to trap and hold a cell for analysis using the patch-clamp technique with sensing electrodes on each side of the cell. Some embodiments of the present invention utilize one or more electrostatic actuators formed on the substrate to provide mechanical stimulation to the cell being analyzed, or to provide information about mechanical movement of the cell in response to electrical or chemical stimulation.

  14. Patch-based frame interpolation for old films via the guidance of motion paths

    NASA Astrophysics Data System (ADS)

    Xia, Tianran; Ding, Youdong; Yu, Bing; Huang, Xi

    2018-04-01

    Due to improper preservation, traditional films will appear frame loss after digital. To deal with this problem, this paper presents a new adaptive patch-based method of frame interpolation via the guidance of motion paths. Our method is divided into three steps. Firstly, we compute motion paths between two reference frames using optical flow estimation. Then, the adaptive bidirectional interpolation with holes filled is applied to generate pre-intermediate frames. Finally, using patch match to interpolate intermediate frames with the most similar patches. Since the patch match is based on the pre-intermediate frames that contain the motion paths constraint, we show a natural and inartificial frame interpolation. We test different types of old film sequences and compare with other methods, the results prove that our method has a desired performance without hole or ghost effects.

  15. Dynamics of skimming flow in the wake of a vegetation patch

    NASA Astrophysics Data System (ADS)

    Mayaud, Jerome R.; Wiggs, Giles F. S.; Bailey, Richard M.

    2016-09-01

    Dryland vegetation is often spatially patchy, and so affects wind flow in complex ways. Theoretical models and wind tunnel testing have shown that skimming flow develops above vegetation patches at high plant densities, resulting in little or no wind erosion in these zones. Understanding the dynamics of skimming flow is therefore important for predicting sediment transport and bedform development in dryland areas. However, no field-based data are available describing turbulent airflow dynamics in the wake of vegetation patches. In this study, turbulent wind flow was examined using high-frequency (10 Hz) sonic anemometry at four measurement heights (0.30 m, 0.55 m, 1.10 m and 1.65 m) along a transect in the lee of an extensive patch of shrubs (z = 1.10 m height) in Namibia. Spatial variations in mean wind velocity, horizontal Reynolds stresses and coherent turbulent structures were analysed. We found that wind velocity in the wake of the patch effectively recovered over ∼12 patch heights (h) downwind, which is 2-5 h longer than previously reported recovery lengths for individual vegetation elements and two-dimensional wind fences. This longer recovery can be attributed to a lack of flow moving around the obstacle in the patch case. The step-change in roughness between the patch canopy and the bare surface in its wake resulted in an initial peak in resultant horizontal shear stress (τr) followed by significant decrease downwind. In contrast to τr , horizontal normal Reynolds stress (u‧2 ‾) progressively increased along the patch wake. A separation of the upper shear layer at the leeside edge of the patch was observed, and a convergence of τr curves implies the formation of a constant stress layer by ∼20 h downwind. The use of τr at multiple heights is found to be a useful tool for identifying flow equilibration in complex aerodynamic regimes. Quadrant analysis revealed elevated frequencies of Q2 (ejection) and Q4 (sweep) events in the immediate lee of the

  16. On the Validity of Repeated Assessments in the UMAT, a High-Stakes Admissions Test

    ERIC Educational Resources Information Center

    Andrich, David; Styles, Irene; Mercer, Annette; Puddey, Ian B.

    2017-01-01

    The possibility that the validity of assessment is compromised by repeated sittings of highly competitive and high profile selection tests has been documented and is of concern to stake-holders. An illustrative example is the Undergraduate Medicine and Health Sciences Admission Test (UMAT) used by some medical and dental courses in Australia and…

  17. Repeated ice water tests and electrical perception threshold determination to detect a neurologic cause of detrusor overactivity.

    PubMed

    van Meel, Tom David; de Wachter, Stefan; Wyndaele, Jean-Jacques

    2007-10-01

    To explore the added value of a repeated ice water test (IWT) and electrical perception threshold (EPT) measurement in the search for a neurologic cause of idiopathic detrusor overactivity (DOA). The IWT, if originally negative, was repeated up to three times, and EPT measurements were done in 63 patients with neurologic DOA, 117 patients with idiopathic DOA without outflow obstruction, and 30 women with stress urinary incontinence without DOA. Although the IWT was positive in 46% of the neurologic patients if used once, this percentage became 86% when the IWT was repeated. In nonneurologic patients, one IWT was positive in only 7% and when repeated, the positive test rate increased to 24%. IWT, even repeated, remained negative in the women with stress urinary incontinence. The EPTs were not significantly different between the neurologic and nonneurologic patients with a positive IWT, except after the third instillation. In those with negative IWTs, the EPTs were significantly different between the neurologic and nonneurologic patients, independent of the number of IWTs done. If the EPTs were compared within each group between those with positive and negative IWTs, the difference was not significant at the first IWT. However, the difference became statistically significant after two IWTs for the nonneurologic group and after three IWTs for both groups. Our results have shown that repeating the IWT will increase its positivity. Combining the IWT and EPT will reinforce the results of both tests and can indicate more clearly the possibility of an unsuspected neurologic pathologic finding in patients with idiopathic DOA.

  18. Acute Doxorubicin Insult in the Mouse Ovary Is Cell- and Follicle-Type Dependent

    PubMed Central

    Roti Roti, Elon C.; Leisman, Scott K.; Abbott, David H.; Salih, Sana M.

    2012-01-01

    Primary ovarian insufficiency (POI) is one of the many unintended consequences of chemotherapy faced by the growing number of female cancer survivors. While ovarian repercussions of chemotherapy have long been recognized, the acute insult phase and primary sites of damage are not well-studied, hampering efforts to design effective intervention therapies to protect the ovary. Utilizing doxorubicin (DXR) as a model chemotherapy agent, we defined the acute timeline for drug accumulation, induced DNA damage, and subsequent cellular and follicular demise in the mouse ovary. DXR accumulated first in the core ovarian stroma cells, then redistributed outwards into the cortex and follicles in a time-dependent manner, without further increase in total ovarian drug levels after four hours post-injection. Consistent with early drug accumulation and intimate interactions with the blood supply, stroma cell-enriched populations exhibited an earlier DNA damage response (measurable at 2 hours) than granulosa cells (measurable at 4 hours), as quantified by the comet assay. Granulosa cell-enriched populations were more sensitive however, responding with greater levels of DNA damage. The oocyte DNA damage response was delayed, and not measurable above background until 10–12 hours post-DXR injection. By 8 hours post-DXR injection and prior to the oocyte DNA damage response, the number of primary, secondary, and antral follicles exhibiting TUNEL (terminal deoxynucleotidyl transferase dUTP nick end labeling)-positive granulosa cells plateaued, indicating late-stage apoptosis and suggesting damage to the oocytes is subsequent to somatic cell failure. Primordial follicles accumulate significant DXR by 4 hours post-injection, but do not exhibit TUNEL-positive granulosa cells until 48 hours post-injection, indicating delayed demise. Taken together, the data suggest effective intervention therapies designed to protect the ovary from chemotherapy accumulation and induced insult in the ovary

  19. Pattern does not equal process: what does patch occupancy really tell us about metapopulation dynamics?

    PubMed

    Clinchy, Michael; Haydon, Daniel T; Smith, Andrew T

    2002-04-01

    Patch occupancy surveys are commonly used to parameterize metapopulation models. If isolation predicts patch occupancy, this is generally attributed to a balance between distance-dependent recolonization and spatially independent extinctions. We investigated whether similar patterns could also be generated by a process of spatially correlated extinctions following a unique colonization event (analogous to nonequilibrium processes in island biogeography). We simulated effects of spatially correlated extinctions on patterns of patch occupancy among pikas (Ochotona princeps) at Bodie, California, using randomly located extinction disks to represent the likely effects of predation. Our simulations produced similar patterns to those cited as evidence of balanced metapopulation dynamics. Simulations using a variety of disk sizes and patch configurations confirmed that our results are potentially applicable to a broad range of species and sites. Analyses of the observed patterns of patch occupancy at Bodie revealed little evidence of rescue effects and strong evidence that most recolonizations are ephemeral in nature. Persistence will be overestimated if static or declining patterns of patch occupancy are mistakenly attributed to dynamically stable metapopulation processes. Consequently, simple patch occupancy surveys should not be considered as substitutes for detailed experimental tests of hypothesized population processes, particularly when conservation concerns are involved.

  20. Chemical analysis of 2,4-toluene diisocyanate, 1,6-hexamethylene diisocyanate and isophorone diisocyanate in petrolatum patch-test preparations.

    PubMed

    Frick-Engfeldt, Malin; Zimerson, Erik; Karlsson, Daniel; Marand, Asa; Skarping, Gunnar; Isaksson, Marléne; Bruze, Magnus

    2005-09-01

    Isocyanates with the general formula R-(N=C=O) are theoretically contact sensitizers. However, allergic contact dermatitis (ACD) from isocyanates is seldom reported. In previous reports, patients reacted to their isocyanate-based work materials but not to commercial patch-test preparations of isocyanates. Therefore, we suspected that the low frequency of reported ACD from isocyanates was partly due to inadequate commercial preparations. A past study also showed the concentrations of diphenylmethane-4,4'-diisocyanate (4,4'-MDI) in petrolatum preparations to be much lower than declared. In this study, 2,4-toluene diisocyanate (2,4-TDI), 1,6-hexamethylene diisocyanate (1,6-HDI), and isophorone diisocyanate (IPDI) were investigated in a similar fashion. In preparations from 12 dermatology departments and two suppliers of patch-test allergens, we determined the isocyanate content as the isocyanate-dibutylamine derivative, using liquid chromatography and mass spectrometry. The preparations were considered stable if the ratio between the stated and found concentrations was within the range of 0.8 to 1.2. Although 28 of 36 investigated preparations had ratios outside of the stable range, they were in its vicinity, which indicates that preparations of 2,4-TDI, 1,6-HDI, and IPDI are more stable than are preparations of 4,4'-MDI where previously reported results showed ratios far outside of stable range. As opposed to preparations of 4,4'-MDI, preparations of 2,4-TDI, 1,6-HDI, and IPDI can be considered to be stable.

  1. Fixation parameter test-retest repeatability of the worse eye in central field loss.

    PubMed

    Samet, Saba; Tarita-Nistor, Luminita; González, Esther G; Mandelcorn, Mark S; Mandelcorn, Efrem D; Steinbach, Martin J

    2018-06-01

    Patients with bilateral central field loss develop peripheral retinal loci (PRLs) in the functional eccentric retina. PRL characteristics and visual performance in the better-seeing eye (BE) of these patients have previously been reported. In this study, we determined the test-retest repeatability of fixation parameters, including fixation stability, PRL eccentricity, and PRL span in the worse-seeing eye (WE). Retrospective consecutive case series. Thirty-six patients with bilateral central field loss referred from the Toronto Western Hospital Retina Clinic, who had completed 2 consecutive fixation examinations on the same day. Fixation stability was recorded using the Nidek MP-1 microperimeter (Nidek Technologies Srl., Padova, Italy). For each fixation recording, the following parameters were retrieved: (i) 68.2% bivariate contour ellipse area (BCEA), (ii) PRL span (major and minor axes of the BCEA), (iii) PRL meridian (polar angle), and (iv) PRL eccentricity. Test-retest repeatability for each parameter was assessed using Bland-Altman plots to determine 95% limits of agreement. The mean difference between the fixation trial pairs and the 95% limits of agreement for fixation stability, PRL major axis, PRL minor axis, PRL meridian, and PRL eccentricity were 0.06 ± 0.47 log deg 2 , 0.05° ± 1.42°, 0.07° ± 0.63°, -0.44° ± 66.0°, and -0.23° ±1.56°, respectively. The fixation parameters in the WE showed robust repeatability, comparable to that of the BE as determined from previous studies. The WE's fixation repeatability should be considered in the interpretation of fixation outcome measures subsequent to treatment interventions. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  2. Preparation and Characterization of Rivastigmine Transdermal Patch Based on Chitosan Microparticles.

    PubMed

    Sadeghi, Mohsen; Ganji, Fariba; Taghizadeh, Seyyed Mojtaba; Daraei, Bahram

    2016-01-01

    Here we report a novel approach for preparation of a 6-day transdermal drug delivery system (TDDS) as treatment for mild to moderate Alzheimer's disease. The spray drying method was used to prepare microparticles containing the anti-Alzheimer drug, Rivastigmine, in combination with the natural polymer, chitosan, for transdermal drug delivery applications. The content of the drug was determined by High Performance Liquid Chromatography (HPLC) method which was validated as per FDA guidelines. The morphology and size range of the microparticles were determined; and the effect of drug concentration in the solution injected into the spray dryer on the particles characterizations was studied. The stability of Rivastigmine at high temperature was confirmed using FTIR analysis as well as a validate HPLC assay. The obtained results show that the drug was stable at high temperatures with 7 to 42% loading in the microparticles, and the higher drug concentrations of the solution injected into the spray dryer resulted in increase of the drug loading, surface drug and microparticles distortion. The TDDS containing the microparticles was also prepared with microparticle to dry adhesive ratios of 5, 10 and 15% using acrylic adhesive. Based on adhesion properties of the patches, gained from the probe tack and the peel adhesion 180° tests, and the 15% patch by having more drug content per unit area of the patch, and still having similar adhesion properties was compared to the microparticles-free patch of 5.1% Rivastigmine salt (equivalent to the drug content of the 15% patch) from the permeation point of view by using Franz cell diffusion over 6 days. The drug permeation rate from the microparticle-free patch was slower than the 15% microparticles patch, which is the result of crystallization of Rivastigmine salt in the acrylic adhesive. The 6-day-prepared TDDS can be considered as an alternative for one-week application of 6 Exelon patches.

  3. Allergy Skin Tests

    MedlinePlus

    ... allergic rhinitis) Allergic asthma Dermatitis (eczema) Food allergies Penicillin allergy Bee venom allergy Latex allergy Skin tests ... check for an allergy to insect venom or penicillin. Patch test Patch testing is generally done to ...

  4. A search theory model of patch-to-patch forager movement with application to pollinator-mediated gene flow.

    PubMed

    Hoyle, Martin; Cresswell, James E

    2007-09-07

    We present a spatially implicit analytical model of forager movement, designed to address a simple scenario common in nature. We assume minimal depression of patch resources, and discrete foraging bouts, during which foragers fill to capacity. The model is particularly suitable for foragers that search systematically, foragers that deplete resources in a patch only incrementally, and for sit-and-wait foragers, where harvesting does not affect the rate of arrival of forage. Drawing on the theory of job search from microeconomics, we estimate the expected number of patches visited as a function of just two variables: the coefficient of variation of the rate of energy gain among patches, and the ratio of the expected time exploiting a randomly chosen patch and the expected time travelling between patches. We then consider the forager as a pollinator and apply our model to estimate gene flow. Under model assumptions, an upper bound for animal-mediated gene flow between natural plant populations is approximately proportional to the probability that the animal rejects a plant population. In addition, an upper bound for animal-mediated gene flow in any animal-pollinated agricultural crop from a genetically modified (GM) to a non-GM field is approximately proportional to the proportion of fields that are GM and the probability that the animal rejects a field.

  5. Masonry fireplace emissions test method: Repeatability and sensitivity to fueling protocol.

    PubMed

    Stern, C H; Jaasma, D R; Champion, M R

    1993-03-01

    A test method for masonry fireplaces has been evaluated during testing on six masonry fireplace configurations. The method determines carbon monoxide and particulate matter emission rates (g/h) and factors (g/kg) and does not require weighing of the appliance to determine the timing of fuel loading.The intralaboratory repeatability of the test method has been determined from multiple tests on the six fireplaces. For the tested fireplaces, the ratio of the highest to lowest measured PM rate averaged 1.17 and in no case was greater than 1.32. The data suggest that some of the variation is due to differences in fuel properties.The influence of fueling protocol on emissions has also been studied. A modified fueling protocol, tested in large and small fireplaces, reduced CO and PM emission factors by roughly 40% and reduced CO and PM rates from 0 to 30%. For both of these fireplaces, emission rates were less sensitive to fueling protocol than emission factors.

  6. Crystal structure of yeast allantoicase reveals a repeated jelly roll motif.

    PubMed

    Leulliot, Nicolas; Quevillon-Cheruel, Sophie; Sorel, Isabelle; Graille, Marc; Meyer, Philippe; Liger, Dominique; Blondeau, Karine; Janin, Joël; van Tilbeurgh, Herman

    2004-05-28

    Allantoicase (EC 3.5.3.4) catalyzes the conversion of allantoate into ureidoglycolate and urea, one of the final steps in the degradation of purines to urea. The mechanism of most enzymes involved in this pathway, which has been known for a long time, is unknown. In this paper we describe the three-dimensional crystal structure of the yeast allantoicase determined at a resolution of 2.6 A by single anomalous diffraction. This constitutes the first structure for an enzyme of this pathway. The structure reveals a repeated jelly roll beta-sheet motif, also present in proteins of unrelated biochemical function. Allantoicase has a hexameric arrangement in the crystal (dimer of trimers). Analysis of the protein sequence against the structural data reveals the presence of two totally conserved surface patches, one on each jelly roll motif. The hexameric packing concentrates these patches into conserved pockets that probably constitute the active site.

  7. Mapped Plot Patch Size Estimates

    Treesearch

    Paul C. Van Deusen

    2005-01-01

    This paper demonstrates that the mapped plot design is relatively easy to analyze and describes existing formulas for mean and variance estimators. New methods are developed for using mapped plots to estimate average patch size of condition classes. The patch size estimators require assumptions about the shape of the condition class, limiting their utility. They may...

  8. Catch and Patch: A Pipette-Based Approach for Automating Patch Clamp That Enables Cell Selection and Fast Compound Application.

    PubMed

    Danker, Timm; Braun, Franziska; Silbernagl, Nikole; Guenther, Elke

    2016-03-01

    Manual patch clamp, the gold standard of electrophysiology, represents a powerful and versatile toolbox to stimulate, modulate, and record ion channel activity from membrane fragments and whole cells. The electrophysiological readout can be combined with fluorescent or optogenetic methods and allows for ultrafast solution exchanges using specialized microfluidic tools. A hallmark of manual patch clamp is the intentional selection of individual cells for recording, often an essential prerequisite to generate meaningful data. So far, available automation solutions rely on random cell usage in the closed environment of a chip and thus sacrifice much of this versatility by design. To parallelize and automate the traditional patch clamp technique while perpetuating the full versatility of the method, we developed an approach to automation, which is based on active cell handling and targeted electrode placement rather than on random processes. This is achieved through an automated pipette positioning system, which guides the tips of recording pipettes with micrometer precision to a microfluidic cell handling device. Using a patch pipette array mounted on a conventional micromanipulator, our automated patch clamp process mimics the original manual patch clamp as closely as possible, yet achieving a configuration where recordings are obtained from many patch electrodes in parallel. In addition, our implementation is extensible by design to allow the easy integration of specialized equipment such as ultrafast compound application tools. The resulting system offers fully automated patch clamp on purposely selected cells and combines high-quality gigaseal recordings with solution switching in the millisecond timescale.

  9. Superconducting antennas for telecommunication applications based on dual mode cross slotted patches

    NASA Astrophysics Data System (ADS)

    Cassinese, A.; Barra, M.; Fragalà, I.; Kusunoki, M.; Malandrino, G.; Nakagawa, T.; Perdicaro, L. M. S.; Sato, K.; Ohshima, S.; Vaglio, R.

    2002-08-01

    Dual mode devices based on high temperature superconducting films represent an interesting class for telecommunication applications since they combine a miniaturized size with a good power handling. Here we report on a novel compact antenna obtained by crossing a square patch with two or more slots. The proposed design has an antenna size reduction of about 40% as compared to the conventional square patch microstrip antennas. Single patch antenna both with linear (LP) and circular (CP) polarization operating in the X-band have been designed and tested at prototype level. They are realized by using double sided (YBa 2Cu 3O 7- x) YBCO and Tl 2Ba 2Ca 1Cu 2O 8 (Tl-2212) superconducting films grown on MgO substrates and tested with a portable cryocooler. They showed at T=77 K a return loss <25 dB and a power handling of 23 dBm. Exemplary 16 elements arrays LP antennas operating in the X band have been also realized by using YBCO film grown on 2 ″ diameter MgO substrate.

  10. Two sensitizing oxidation products of p-phenylenediamine patch tested in patients allergic to p-phenylenediamine.

    PubMed

    Young, Ewa; Zimerson, Erik; Bruze, Magnus; Svedman, Cecilia

    2016-02-01

    The results from a previous study indicated the presence of several possible sensitizers formed during oxidation of the potent sensitizer p-phenylenediamine (PPD) to which PPD-sensitized patients might react, in various patterns. To extract and analyse a yellow spot from a thin-layer chromatogram with oxidized PPD, to which 6 of 14 (43%) PPD-positive patients had reacted in a previous study, in order to identify potential sensitizer(s) and to patch test this/these substance(s) in the 14 PPD-positive patients. The yellow spot was extracted from a thin-layer chromatogram of oxidized PPD, and two substances, suspected to be allergens, were identified by analysis with gas chromatography mass spectrometry (GCMS). The 14 PPD-positive patients, who had been previously tested with the thin-layer chromatogram of oxidized PPD, participated in the investigation, and were tested with dilutions of the two substances. GCMS analysis identified 4-nitroaniline and 4,4'-azodianiline in the yellow spot. Of the 14 PPD-positive test patients, 5 (36%) reacted to 4-nitroaniline and 9 (64%) reacted to 4,4'-azodianiline. The results show that 4-nitroaniline and 4,4'-azodianiline, formed during oxidation of PPD, are potent sensitizers. PPD-sensitized patients react to a high extent to concentrations equimolar to PPD of 4-nitroaniline and 4,4'-azodianiline. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. QPatch: the past, present and future of automated patch clamp.

    PubMed

    Mathes, Chris

    2006-04-01

    The QPatch 16 significantly increases throughput for gigaseal patch clamp experiments, making direct measurements in ion channel drug discovery and safety testing feasible. Released to the market in the Autumn of 2004 by Sophion Bioscience, the QPatch originated from work done at NeuroSearch (Denmark) in the early days of automated patch clamp. Today, the QPatch provides many unique features. For example, only the QPatch includes an automated cell preparation station making several hours of unattended operation possible. The 16-channel electrode array, called the QPlate, includes glass-coated microfluidic channels for less compound absorption and, hence, more accurate IC(50) values. The microfluidic pathways also allow for very small amounts of compound used for each experiment ( approximately 5 microl per addition). Only the QPatch has four independent pipetting heads for more efficient liquid handling (especially for ligand-gated ion channel experiments). Patch clamp recordings with the QPatch match the high quality of conventional patch clamp and in some cases the results are even better. For example, only the QPatch includes 100% series resistance compensation for the elimination of false positives due to voltage errors. Finally, the modular QPatch 16 was designed with more channels in mind. The upgrade pathway to 48-channels (the QPatch HT) will be discussed.

  12. Light transmission and preference of eye patches for occlusion treatment.

    PubMed

    Heo, Hwan; Park, Jung Won; Park, Sang Woo

    2013-01-01

    To investigate light transmission and preference for six eye patches for occlusion therapy. Six patches were examined, including; Ortopad Fun Pack, Ortopad Flesh, Kawamoto A-1, Kawamoto A-2, 3M Opticlude, and Everade Eye Guard. The size and the presence of a light blocking pad of patches were investigated. The amount of light transmitted through the patches was evaluated, using a digital light meter and a model eye, in three different environments; indoors with fluorescent light, outdoors on a sunny day, and strong light from illuminator. After patching the normal eye, the flash visual evoked potential (VEP) was measured. Thirty patients with amblyopia or horizontal strabismus, who received occlusion therapy as initial treatment, were included. After using all six patches, patients completed a 7-item questionnaire regarding the patch preference for size, color and shape, adhesive power, pain with removal, skin irritation after removing patch, parent's preference and overall opinion. All patches had a light-blocking pad, except the 3M Nexcare. Ortopad had the strongest light blocking power in the three environments, and the 3M Nexcare had the weakest power. In flash VEP, Ortopad and Kawamoto patches showed flat, but 3M Nexcare and Everade Eye Guard showed normal response. There were significant preferential differences among the patches in all the items of the questionnaire (P<0.05). In comparison between the patches respectively, 3M Nexcare received the lowest satisfaction in pain when removing a patch and skin irritation after removing a patch. Kawamoto A-2 received the lowest score in the overall satisfaction. We found differences in the light-blocking power and in the preference of the various patches for the occlusion treatment. This is a pilot study regarding only characteristics and preferences of patches. Further clinical studies regarding the relationship between characteristics or preferences of patches and outcomes of occlusion treatment are needed.

  13. Word play, ritual insult, and volleyball in Peru.

    PubMed

    Perez, Justin

    2011-01-01

    Many gay men in the popular sectors of Lima, Peru participate in vóley callejero, or street volleyball. The ethnographic data presented in this article describes verbal and corporal mechanisms through which gay identity emerges within the particular context of the street volleyball game, ultimately highlighting the contextual nature of identity. The volleyball players are not just hitting a ball back and forth, they are engaging in a meaningful activity that illuminates intersections of language, sexuality, and identity. Through the manipulation of the street into a volleyball court, the volleyball players create a space conducive to the articulation of particular verbal and embodied practices that index gay identity. The challenge to the regulations of "proper" volleyball through the practice of ritual insulting and the cultivation of gay volleyball technique are playful reconfigurations of gendered practices prominent in the sites where fieldwork was carried out.

  14. Multi-objective design optimization of antenna structures using sequential domain patching with automated patch size determination

    NASA Astrophysics Data System (ADS)

    Koziel, Slawomir; Bekasiewicz, Adrian

    2018-02-01

    In this article, a simple yet efficient and reliable technique for fully automated multi-objective design optimization of antenna structures using sequential domain patching (SDP) is discussed. The optimization procedure according to SDP is a two-step process: (i) obtaining the initial set of Pareto-optimal designs representing the best possible trade-offs between considered conflicting objectives, and (ii) Pareto set refinement for yielding the optimal designs at the high-fidelity electromagnetic (EM) simulation model level. For the sake of computational efficiency, the first step is realized at the level of a low-fidelity (coarse-discretization) EM model by sequential construction and relocation of small design space segments (patches) in order to create a path connecting the extreme Pareto front designs obtained beforehand. The second stage involves response correction techniques and local response surface approximation models constructed by reusing EM simulation data acquired in the first step. A major contribution of this work is an automated procedure for determining the patch dimensions. It allows for appropriate selection of the number of patches for each geometry variable so as to ensure reliability of the optimization process while maintaining its low cost. The importance of this procedure is demonstrated by comparing it with uniform patch dimensions.

  15. The patch distributed producer-scrounger game.

    PubMed

    Ohtsuka, Yasunori; Toquenaga, Yukihiko

    2009-09-21

    Grouping in animals is ubiquitous and thought to provide group members antipredatory advantages and foraging efficiency. However, parasitic foraging strategy often emerges in a group. The optimal parasitic policy has given rise to the producer-scrounger (PS) game model, in which producers search for food patches, and scroungers parasitize the discovered patches. The N-persons PS game model constructed by Vickery et al. (1991. Producers, scroungers, and group foraging. American Naturalist 137, 847-863) predicts the evolutionarily stable strategy (ESS) of frequency of producers (q;) that depends on the advantage of producers and the number of foragers in a group. However, the model assumes that the number of discovered patches in one time unit never exceeds one. In reality, multiple patches could be found in one time unit. In the present study, we relax this assumption and assumed that the number of discovered patches depends on the producers' variable encounter rate with patches (lambda). We show that q; strongly depends on lambda within a feasible range, although it still depends on the advantage of producer and the number of foragers in a group. The basic idea of PS game is the same as the information sharing (parasitism), because scroungers are also thought to parasitize informations of locations of food patches. Horn (1968) indicated the role of information-parasitism in animal aggregation (Horn, H.S., 1968. The adaptive significance of colonial nesting in the Brewer's blackbird (euphagus cyanocephalus). Ecology 49, 682-646). Our modified PS game model shows the same prediction as the Horn's graphical animal aggregation model; the proportion of scroungers will increase or animals should adopt colonial foraging when resource is spatiotemporally clumped, but scroungers will decrease or animals should adopt territorial foraging if the resource is evenly distributed.

  16. Evaluation of concrete pavement patching techniques.

    DOT National Transportation Integrated Search

    1989-01-01

    This final report presents the results of a study undertaken to improve in concrete pavement patching techniques. Activities included an evaluation of the suitability of the impact hammer and maturity calculations for determining when a patch is read...

  17. Depletion of deep marine food patches forces divers to give up early.

    PubMed

    Thums, Michele; Bradshaw, Corey J A; Sumner, Michael D; Horsburgh, Judy M; Hindell, Mark A

    2013-01-01

    Many optimal foraging models for diving animals examine strategies that maximize time spent in the foraging zone, assuming that prey acquisition increases linearly with search time. Other models have considered the effect of patch quality and predict a net energetic benefit if dives where no prey is encountered early in the dive are abandoned. For deep divers, however, the energetic benefit of giving up is reduced owing to the elevated energy costs associated with descending to physiologically hostile depths, so patch residence time should be invariant. Others consider an asymptotic gain function where the decision to leave a patch is driven by patch-depletion effects - the marginal value theorem. As predator behaviour is increasingly being used as an index of marine resource density and distribution, it is important to understand the nature of this gain function. We investigated the dive behaviour of the world's deepest-diving seal, the southern elephant seal Mirounga leonina, in response to patch quality. Testing these models has largely been limited to controlled experiments on captive animals. By integrating in situ measurements of the seal's relative lipid content obtained from drift rate data (a measure of foraging success) with area-restricted search behaviour identified from first-passage time analysis, we identified regions of high- and low-quality patches. Dive durations and bottom times were not invariant and did not increase in regions of high quality; rather, both were longer when patches were of relatively low quality. This is consistent with the predictions of the marginal value theorem and provides support for a nonlinear relationship between search time and prey acquisition. We also found higher descent and ascent rates in high-quality patches suggesting that seals minimized travel time to the foraging patch when quality was high; however, this was not achieved by increasing speed or dive angle. Relative body lipid content was an important

  18. Habitat quality and geometry affect patch occupancy of two Orthopteran species.

    PubMed

    Pasinelli, Gilberto; Meichtry-Stier, Kim; Birrer, Simon; Baur, Bruno; Duss, Martin

    2013-01-01

    Impacts of habitat loss and fragmentation on distribution and population size of many taxa are well established. In contrast, less is known about the role of within-patch habitat quality for the spatial dynamics of species, even though within-patch habitat quality may substantially influence the dynamics of population networks. We studied occurrence patterns of two Orthopteran species in relation to size, isolation and quality of habitat patches in an intensively managed agricultural landscape (16.65 km(2)) in the Swiss lowland. Occurrence of field crickets (Gryllus campestris) was positively related to patch size and negatively to the distance to the nearest occupied patch, two measures of patch geometry. Moreover, field crickets were more likely to occur in extensively managed meadows, meadows used at low intensity and meadows dominated by Poa pratensis, three measures of patch quality. Occurrence of the large gold grasshopper (Chrysochraon dispar) was negatively related to two measures of patch geometry, distance to the nearest occupied patch and perimeter index (ratio of perimeter length to patch area). Further, large gold grasshoppers were more likely to occupy patches close to water and patches with vegetation left uncut over winter, two measures of patch quality. Finally, examination of patch occupancy dynamics of field crickets revealed that patches colonized in 2009 and patches occupied in both 2005 and 2009 were larger, better connected and of other quality than patches remaining unoccupied and patches from which the species disappeared. The strong relationships between Orthopteran occurrence and aspects of patch geometry found in this study support the "area-and-isolation paradigm". Additionally, our study reveals the importance of patch quality for occurrence patterns of both species, and for patch occupancy dynamics in the field cricket. An increased understanding of patch occupancy patterns may be gained if inference is based on variables related to

  19. Outcomes of using a sutureless bovine pericardial patch graft for Ahmed glaucoma valve implantation.

    PubMed

    Quaranta, Luciano; Riva, Ivano; Floriani, Irene C

    2013-01-01

    To evaluate the long-term outcomes of a surgical technique using a sutureless bovine pericardial patch graft for the implantation of an Ahmed glaucoma valve (AGV). 
 This was a pilot study on patients with primary open-angle glaucoma refractory to repeated surgical filtering procedures. All patients underwent AGV implant technique using a sutureless bovine pericardial patch graft. The pericardial membrane was cut using an ordinary corneal trephine with a diameter of 9.0 or 10.0 mm. The anterior part of the tube was covered with the graft and kept in place with fibrin glue. Subsequently, the cap was stitched all around the tube and the dissected conjunctiva was laid over it. Intraocular pressure (IOP) and complications were evaluated 1 week and 1, 3, 6, 12, and 24 months after surgery.
 The procedure was used to treat 20 eyes of 20 consecutive patients (12 men and 8 women: mean age [SD] 64.8 [7.8] years). Mean IOP was 28.1 mm Hg (SD 4.9) at baseline and decreased to 14.9 mm Hg (SD 1.5) 24 months after surgery (p<0.001). The overall mean number of topical medications was 3.1 (SD 0.5) at baseline and decreased to 1.4 (SD 0.8) after 24 months (p<0.001). During follow-up, there was no conjunctival erosion, thinning of pericardial patch graft over the tube, or tube exposure; no signs of endophthalmitis were recorded.
 The results suggest that the sutureless technique using a bovine pericardial graft patch is a safe and rapid procedure for AGV implantation.

  20. Relationships of habitat patch size to predator community and survival of duck nests

    USGS Publications Warehouse

    Sovada, M.A.; Zicus, M.C.; Greenwood, R.J.; Rave, D.P.; Newton, W.E.; Woodward, R.O.; Beiser, J.A.

    2000-01-01

    We studied duck nest success and predator community composition in relation to size of discrete patches of nesting cover in the Prairie Pothole Region (PPR) of the United States in 1993-95. We focused on nests in uplands that were seeded to perennial grasses and forbs and enrolled in the Conservation Reserve Program (CRP) in Minnesota, North Dakota, and South Dakota. We estimated daily survival rates (DSRs) of upland duck nests and indices of activity for red foxes (Vulpes vulpes), coyotes (Canis latrans), American badgers (Taxidea taxus), striped skunks (Mephitis mephitis), and Franklin's ground squirrels (Spermophilus franklinii), and related these variables to habitat patch size. The effect of patch size (small vs. large) on estimated annual mean DSR was dependent on date of nest initiation (early vs. late) and year. Examination of within-year comparisons for early and late nests suggested that DSR was generally greater in larger habitat patches. Activity indices for the 5 mammalian nest predators were influenced differently by year, location, and patch size. Activity indices of the red fox were greatest in small patches. Coyote indices were the most inconsistent, demonstrating a year X location X patch size interaction. Activity indices of the striped skunk and American badger varied only among years. Franklin's ground squirrel indices were affected by study area location, with higher indices in the southeast than the northwest. Red fox activity was weakly correlated with that of the striped skunk and coyote. Although a positive relationship between habitat patch size and nest success probably exists, we believe the experiment to fully test this hypothesis will continue to be elusive.

  1. Allergic contact dermatitis pattern in Kuwait: nickel leads the pack. In-depth analysis of nickel allergy based on the results from a large prospective patch test series report

    PubMed Central

    Almutawa, Fahad

    2017-01-01

    Introduction Contact dermatitis is a relatively common dermatosis reported among several population groups from all around the globe. However, the data from Kuwait is unavailable. Patch tests are essential for the diagnosis of contact sensitization. Aim To determine a relative frequency and pattern of sensitizers to different allergens in patients of suspected contact dermatitis in Kuwait and, also to study the role of the commonest sensitizer in detail. Material and methods Patch tests were performed in 2461 consecutive patients with a clinical diagnosis of contact dermatitis seen at our hospital between September 1, 2014 and August 31, 2015. Out of the total of 1381 (56.1%) patients with positive patch test results to at least one allergen, 546 (22.2%) patients with a single positive reaction to nickel only (single largest sensitizer) were selected as the study population for further detailed analysis. Results At least one positive patch test reaction was found in 1381 (56.12%) patients. Nickel was found to be the most common sensitizer seen in 546 (40%) patients. The mean age was 37.3 ±13.8 years and the mean duration of disease was 27.3 ±13.8 months. Most (387/546) patients sensitized were females. The forearms/hands and wrists were the most prevalent sites (52.56% of the participants). In 58.91% of women, dermatitis was more often confined to other sites, mostly ears and the neck due to earrings and necklaces. Just more than half of the number (51.09%) of nickel allergic patients were found in the age group of 15–25 years. Hairdressers/beauticians were the most affected group followed by house workers (housewives, cleaners, housekeepers). Conclusions Nickel is the single most common sensitizer found in our patients, and female sex, young age, occupation with long hours of contact to nickel are high risk factors. We recommend that a directive, which limits the release of nickel from products with extended skin contact, be approved in Kuwait. PMID:28670248

  2. Macronutrient balancing affects patch departure by guerezas (Colobus guereza).

    PubMed

    Johnson, Caley A; Raubenheimer, David; Chapman, Colin A; Tombak, Kaia J; Reid, Andrea J; Rothman, Jessica M

    2017-04-01

    Foraging strategies are central in shaping social structure and grouping patterns in primates. We address Colobus guereza foraging strategies by investigating their patch departure decisions in relation to diet composition and nutrition. We examine whether guerezas are constrained in their intake of food in patches and thereby forage according to a fixed amount strategy that dictates patch departure. Additionally, we assess whether guereza employ a fixed time strategy or attempt to balance nutrients when foraging. We measured food patch occupancy time, intake rates, and analyzed foods for macronutrients, fiber, and condensed tannins. We determined that guerezas do not employ a fixed time foraging strategy; patch residence time varied widely between 1 and 290 min. They also did not depart patches or stop eating when they reached a specific intake of dry mass, macronutrients, or condensed tannins. However, guerezas maintained a macronutrient balance when feeding across patches, and the balance of protein to non-protein energy (fats and carbohydrates) in patches is the best indicator of time adult guerezas spent feeding in patches. Previous studies have shown that the protein-to-fiber ratio is important in predicting food selection for folivores and their biomass; however, we found that guerezas did not maximize protein and minimize fiber intake while foraging in patches, nor did they stay longer in patches with the highest ratio of protein to fiber concentrations. This study raises questions about the nutritional and social implications of patch depletion as a foraging strategy in folivorous monkeys where food limitation predicts competitive and social regimes. Am. J. Primatol. 79:e22495, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  3. Variability of Slip Behavior in Simulations of Dynamic Rupture Interaction With Stronger Fault Patches Over Long-Term Deformation Histories

    NASA Astrophysics Data System (ADS)

    Lapusta, N.; Liu, Y.

    2007-12-01

    , supershear propagation and additional slip accumulation around the patch are never repeated in the simulated history of the fault, and the patch stops manifesting itself as a seismic asperity. This is due to higher shear stress that is established at the patch after the first earthquake cycle. For patches with higher normal stress, shear stress redistribution also occurs, but it is less effective. The patches with 40% and 60% higher normal stress continue to affect rupture speed and fault slip in some of subsequent events, although the effect is much diminished with respect to the first event. For example, there are no supershear bursts. The patch with 100% higher normal stress is first broken in the second large event, and it retains significant influence on rupture speed and slip throughout the fault history, occasionally resulting in supershear bursts. Additional slip complexity emerges for patches with 40% and higher normal stress contrast. Since higher normal stress corresponds to a smaller nucleation size, nucleation of some events moves from the rheological transitions (where nucleation occurs in the cases with no stronger patch and with the patch of 20% higher normal stress) to the patches of higher normal stress. The patches nucleate both large, model-spanning, events, and small events that arrest soon after exiting the patch. Hence not every event that originates at the location of a potential seismic asperity is destined to be large, as its subsequent propagation is significantly influenced by the state of stress outside the patch.

  4. Identifying preferred habitats of samango monkeys (Cercopithecus (nictitans) mitis erythrarchus) through patch use.

    PubMed

    Emerson, Sara E; Brown, Joel S

    2013-11-01

    To examine habitat preferences of two groups of samango monkeys (Cercopithecus (nictitans) mitis erythrarchus) in the Soutpansberg, South Africa, we used experimental food patches in fragments of tall forest and in bordering secondary growth short forest. Additionally, to test for the impacts of group cohesion and movement on habitat use, we tested for the interaction of space and time in our analyses of foraging intensity in the experimental food patches placed throughout the home ranges of the two groups. We expected the monkeys to harvest the most from patches in tall forest habitats and the least from patches in short forest. Further, because the monkeys move through their habitats in groups, we expected to see group cohesion effects illustrated by daily spatial variation in the monkeys’ use of widespread foraging grids. In the forest height experiments, the two groups differed in their foraging responses, with 8% greater foraging overall for one group. However, forest height did not significantly impact foraging in either group, meaning that, given feeding opportunities, samango monkeys are able to utilise secondary growth forest. For one group, missed opportunity costs of staying with the group appeared through the statistical interaction of day with foraging location (the monkeys did not always spread out to take advantage of all available food patches). In several subsequent experiments in widespread grids, significant daily spatial variation in foraging occurred, pointing to spatial cohesion during group movement as likely being an important predictor of habitat use. For an individual social forager, staying with the group may be more important than habitat type in driving habitat selection.

  5. Repeatability and uncertainty analyses of light gas gun test data

    NASA Technical Reports Server (NTRS)

    Schonberg, William P.; Cooper, David

    1994-01-01

    All large spacecraft are susceptible to high-speed impacts by meteoroids and pieces of orbiting space debris which can damage flight-critical systems and in turn lead to catastrophic failure. One way to obtain information on the response of a structure to a meteoroid impact or an orbital debris impact is to simulate the impact conditions of interest in the laboratory and analyze the resulting damage to a target structure. As part of the Phase B and C/D development activities for the Space Station Freedom, 950 impact tests were performed using the NASA/Marshall Space Flight Center (MSFC) light gas gun from 1985-1991. This paper presents the results of impact phenomena repeatability and data uncertainty studies performed using the information obtained from those tests. The results of these studies can be used to assess the utility of individual current and future NASA/MSFC impact test results in the design of long-duration spacecraft.

  6. Fatigue behavior of a thermally-activated NiTiNb SMA-FRP patch

    NASA Astrophysics Data System (ADS)

    El-Tahan, M.; Dawood, M.

    2016-01-01

    This paper presents the details of an experimental study that was conducted to characterize the fatigue behavior of a thermally-activated shape memory alloy (SMA)/carbon fiber reinforced polymer (CFRP) patch that can be used to repair cracked steel members. A total of 14 thermally-activated patches were fabricated and tested to evaluate the stability of the prestress under fatigue loading. The parameters considered in this study are the prestress level in the nickel-titanium-niobium SMA wires and the applied force range. An empirical model to predict the degradation of the prestress is also presented. The results indicate that patches for which the maximum applied loads in a fatigue cycle did not cause debonding of the SMA wires from the CFRP sustained two million loading cycles with less than 20% degradation of the prestress.

  7. Repeating aftershocks of the great 2004 Sumatra and 2005 Nias earthquakes

    NASA Astrophysics Data System (ADS)

    Yu, Wen-che; Song, Teh-Ru Alex; Silver, Paul G.

    2013-05-01

    We investigate repeating aftershocks associated with the great 2004 Sumatra-Andaman (Mw 9.2) and 2005 Nias-Simeulue (Mw 8.6) earthquakes by cross-correlating waveforms recorded by the regional seismographic station PSI and teleseismic stations. We identify 10 and 18 correlated aftershock sequences associated with the great 2004 Sumatra and 2005 Nias earthquakes, respectively. The majority of the correlated aftershock sequences are located near the down-dip end of a large afterslip patch. We determine the precise relative locations of event pairs among these sequences and estimate the source rupture areas. The correlated event pairs identified are appropriately referred to as repeating aftershocks, in that the source rupture areas are comparable and significantly overlap within a sequence. We use the repeating aftershocks to estimate afterslip based on the slip-seismic moment scaling relationship and to infer the temporal decay rate of the recurrence interval. The estimated afterslip resembles that measured from the near-field geodetic data to the first order. The decay rate of repeating aftershocks as a function of lapse time t follows a power-law decay 1/tp with the exponent p in the range 0.8-1.1. Both types of observations indicate that repeating aftershocks are governed by post-seismic afterslip.

  8. Complex interaction of dendritic connectivity and hierarchical patch size on biodiversity in river-like landscapes.

    PubMed

    Carrara, Francesco; Rinaldo, Andrea; Giometto, Andrea; Altermatt, Florian

    2014-01-01

    Habitat fragmentation and land use changes are causing major biodiversity losses. Connectivity of the landscape or environmental conditions alone can shape biodiversity patterns. In nature, however, local habitat characteristics are often intrinsically linked to a specific connectivity. Such a link is evident in riverine ecosystems, where hierarchical dendritic structures command related scaling on habitat capacity. We experimentally disentangled the effect of local habitat capacity (i.e., the patch size) and dendritic connectivity on biodiversity in aquatic microcosm metacommunities by suitably arranging patch sizes within river-like networks. Overall, more connected communities that occupy a central position in the network exhibited higher species richness, irrespective of patch size arrangement. High regional evenness in community composition was found only in landscapes preserving geomorphological scaling properties of patch sizes. In these landscapes, some of the rarer species sustained regionally more abundant populations better tracking their own niche requirements compared to landscapes with homogeneous patch size or landscapes with spatially uncorrelated patch size. Our analysis suggests that altering the natural link between dendritic connectivity and patch size strongly affects community composition and population persistence at multiple scales. The experimental results are demonstrating a principle that can be tested in theoretical metacommunity models and eventually be projected to real riverine ecosystems.

  9. Repeatability of Monocular Acuity Testing in Adults with and without Down Syndrome.

    PubMed

    Ravikumar, Ayeswarya; Benoit, Julia S; Morrison, Kelsie B; Marsack, Jason D; Anderson, Heather A

    2018-03-01

    Individuals with Down syndrome may experience greater difficulty reliably performing visual acuity (VA) tests because of intellectual disability and limitations in visual quality. This study evaluated the repeatability of acuity (Bailey-Lovie [BL] and HOTV) in subjects with and without Down syndrome. High-contrast VA was measured in both eyes of 30 subjects with Down syndrome (mean, 30 years; range, 18 to 50 years) and 24 control subjects without Down syndrome (mean, 29 years; range, 18 to 50 years). In the Down syndrome group, 23 subjects performed BL, and 7 subjects performed HOTV. All control subjects performed both BL and HOTV, but for HOTV analysis, only seven age-matched control subjects were included. For each eye, subjects performed VA three times on different charts (computer controlled, single-line display) until five total letters were missed on each chart. A repeated-measure ANOVA was used to compare the acuity measures between groups. The average logMAR VA for subjects with Down syndrome was approximately six lines worse than the control subjects (BL: Down syndrome = right eye: 0.51 ± 0.16, left eye: 0.53 ± 0.18; control = right eye: -0.06 ± 0.06, left eye: -0.06 ± 0.08, P < .0001; HOTV: Down syndrome = right eye: 0.47 ± 0.19, left eye: 0.46 ± 0.16; control: right eye = -0.11 ± 0.09, left eye: -0.07 ± 0.07, P < .001). Bailey-Lovie VA repeatability (1.96 * Sw * √2) was 0.13 logMAR (6.5 letters) for Down syndrome and 0.09 logMAR (4.5 letters) for control subjects. HOTV VA repeatability was 0.16 logMAR (eight letters) for both Down syndrome and control subjects. Despite poorer acuity in individuals with Down syndrome, repeatability of VA measurements was comparable to control subjects for both BL and HOTV techniques.

  10. Multi-Band Miniaturized Patch Antennas for a Compact, Shielded Microwave Breast Imaging Array.

    PubMed

    Aguilar, Suzette M; Al-Joumayly, Mudar A; Burfeindt, Matthew J; Behdad, Nader; Hagness, Susan C

    2013-12-18

    We present a comprehensive study of a class of multi-band miniaturized patch antennas designed for use in a 3D enclosed sensor array for microwave breast imaging. Miniaturization and multi-band operation are achieved by loading the antenna with non-radiating slots at strategic locations along the patch. This results in symmetric radiation patterns and similar radiation characteristics at all frequencies of operation. Prototypes were fabricated and tested in a biocompatible immersion medium. Excellent agreement was obtained between simulations and measurements. The trade-off between miniaturization and radiation efficiency within this class of patch antennas is explored via a numerical analysis of the effects of the location and number of slots, as well as the thickness and permittivity of the dielectric substrate, on the resonant frequencies and gain. Additionally, we compare 3D quantitative microwave breast imaging performance achieved with two different enclosed arrays of slot-loaded miniaturized patch antennas. Simulated array measurements were obtained for a 3D anatomically realistic numerical breast phantom. The reconstructed breast images generated from miniaturized patch array data suggest that, for the realistic noise power levels assumed in this study, the variations in gain observed across this class of multi-band patch antennas do not significantly impact the overall image quality. We conclude that these miniaturized antennas are promising candidates as compact array elements for shielded, multi-frequency microwave breast imaging systems.

  11. The effect of altitude, patch size and disturbance on species richness and density of lianas in montane forest patches

    NASA Astrophysics Data System (ADS)

    Mohandass, Dharmalingam; Campbell, Mason J.; Hughes, Alice C.; Mammides, Christos; Davidar, Priya

    2017-08-01

    The species richness and density of lianas (woody vines) in tropical forests is determined by various abiotic and biotic factors. Factors such as altitude, forest patch size and the degree of forest disturbance are known to exert strong influences on liana species richness and density. We investigated how liana species richness and density were concurrently influenced by altitude (1700-2360 m), forest patch size, forest patch location (edge or interior) and disturbance intensity in the tropical montane evergreen forests, of the Nilgiri and Palni hills, Western Ghats, southern India. All woody lianas (≥1 cm dbh) were enumerated in plots of 30 × 30 m in small, medium and large forest patches, which were located along an altitudinal gradient ranging from 1700 to 2360 m. A total of 1980 individual lianas were recorded, belonging to 45 species, 32 genera and 21 families, from a total sampling area of 13.86 ha (across 154 plots). Liana species richness and density decreased significantly with increasing altitude and increased with increasing forest patch size. Within forest patches, the proportion of forest edge or interior habitat influenced liana distribution and succession especially when compared across the patch size categories. Liana species richness and density also varied along the altitudinal gradient when examined using eco-physiological guilds (i.e. shade tolerance, dispersal mode and climbing mechanism). The species richness and density of lianas within these ecological guilds responded negatively to increasing altitude and positively to increasing patch size and additionally displayed differing sensitivities to forest disturbance. Importantly, the degree of forest disturbance significantly altered the relationship between liana species richness and density to increasing altitude and patches size, and as such is likely the primary influence on liana response to montane forest succession. Our findings suggest that managing forest disturbance in the examined

  12. Protection of the female reproductive system from natural and artificial insults

    DOEpatents

    Tilly, Jonathan L.; Kolesnick, Richard N.

    2010-12-14

    Described are methods for protecting the female reproductive system against natural and artificial insults by administering to women a composition comprising an agent that antagonizes one or more acid sphingomyelinase (ASMase) gene products. Specifically, methods disclosed herein serve to protect women's germline from damage resulting from cancer therapy regimens including chemotherapy or radiotherapy. In one aspect, the method preserves, enhances, or revives ovarian function in women, by administering to women a composition containing sphingosine-1-phosphate, or an analog thereof. Also disclosed are methods to prevent or ameliorate menopausal syndromes and to improve in vitro fertilization techniques.

  13. Broadband Circularly Polarized Patch Antenna and Method

    DTIC Science & Technology

    2016-09-16

    300152 1 of 14 BROADBAND CIRCULARLY POLARIZED PATCH ANTENNA AND METHOD STATEMENT OF GOVERNMENT INTEREST [0001] The invention described herein may...present invention provides a method and apparatus for a broadband circularly polarized patch antenna . (2) Description of the Prior Art [0004] A...patch antenna , also referred to as a microstrip antenna , is a type of radio antenna with a low profile that can be mounted on a flat surface. The

  14. Compliance and patching and atropine amblyopia treatments.

    PubMed

    Wang, Jingyun

    2015-09-01

    In the past 20 years, there has been a great advancement in knowledge pertaining to compliance with amblyopia treatments. The occlusion dose monitor introduced quantitative monitoring methods in patching, which sparked our initial understanding of the dose-response relationship for patching amblyopia treatment. This review focuses on current compliance knowledge and the impact it has on patching and atropine amblyopia treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Repeat HIV-testing is associated with an increase in behavioral risk among men who have sex with men: a cohort study.

    PubMed

    Hoenigl, Martin; Anderson, Christy M; Green, Nella; Mehta, Sanjay R; Smith, Davey M; Little, Susan J

    2015-09-11

    The Center for Disease Control and Prevention recommends that high-risk groups, like sexually active men who have sex with men (MSM), receive HIV testing and counseling at least annually. The objective of this study was to investigate the relationship between voluntary repeat HIV testing and sexual risk behavior in MSM receiving rapid serologic and nucleic acid amplification testing. We performed a cohort study to analyze reported risk behavior among MSM receiving the "Early Test", a community-based, confidential acute and early HIV infection screening program in San Diego, California, between April 2008 and July 2014. The study included 8,935 MSM receiving 17,333 "Early Tests". A previously published risk behavior score for HIV acquisition in MSM (i.e. Menza score) was chosen as an outcome to assess associations between risk behaviors and number of repeated tests. At baseline, repeat-testers (n = 3,202) reported more male partners and more condomless receptive anal intercourse (CRAI) when compared to single-testers (n = 5,405, all P <0.001). In 2,457 repeat testers there was a strong association observed between repeated HIV tests obtained and increased risk behavior, with number of male partners, CRAI with high risk persons, non-injection stimulant drug use, and sexually transmitted infections all increasing between the first and last test. There was also a linear increase of risk (i.e. high Menza scores) with number of tests up to the 17th test. In the multivariable mixed effects model, more HIV tests (OR = 1.18 for each doubling of the number of tests, P <0.001) and younger age (OR = 0.95 per 5-year increase, P = 0.006) had significant associations with high Menza scores. This study found that the highest risk individuals for acquiring HIV (e.g. candidates for antiretroviral pre-exposure prophylaxis) can be identified by their testing patterns. Future studies should delineate causation versus association to improve prevention messages delivered to repeat

  16. Comparison of human skin irritation patch test data with in vitro skin irritation assays and animal data.

    PubMed

    Jírová, Dagmar; Basketter, David; Liebsch, Manfred; Bendová, Hana; Kejlová, Kristina; Marriott, Marie; Kandárová, Helena

    2010-02-01

    Efforts to replace the rabbit skin irritation test have been underway for many years, encouraged by the EU Cosmetics Directive and REACH. Recently various in vitro tests have been developed, evaluated and validated. A key difficulty in confirming the validity of in vitro methods is that animal data are scarce and of limited utility for prediction of human effects, which adversely impacts their acceptance. This study examines whether in vivo or in vitro data most accurately predicted human effects. Using the 4-hr human patch test (HPT) we examined a number of chemicals whose EU classification of skin irritancy is known to be borderline, or where in vitro methods provided conflicting results. Of the 16 chemicals classified as irritants in the rabbit, only five substances were found to be significantly irritating to human skin. Concordance of the rabbit test with the 4-hr HPT was only 56%, whereas concordance of human epidermis models with human data was 76% (EpiDerm) and 70% (EPISKIN). The results confirm observations that rabbits overpredict skin effects in humans. Therefore, when validating in vitro methods, all available information, including human data, should be taken into account before making conclusions about their predictive capacity.

  17. Scattering from arbitrarily shaped microstrip patch antennas

    NASA Technical Reports Server (NTRS)

    Shively, David G.; Deshpande, Manohar D.; Cockrell, Capers R.

    1992-01-01

    The scattering properties of arbitrarily shaped microstrip patch antennas are examined. The electric field integral equation for a current element on a grounded dielectric slab is developed for a rectangular geometry based on Galerkin's technique with subdomain rooftop basis functions. A shape function is introduced that allows a rectangular grid approximation to the arbitrarily shaped patch. The incident field on the patch is expressed as a function of incidence angle theta(i), phi(i). The resulting system of equations is then solved for the unknown current modes on the patch, and the electromagnetic scattering is calculated for a given angle. Comparisons are made with other calculated results as well as with measurements.

  18. Transdermal nicotine patches for eosinophilic pustular folliculitis.

    PubMed

    Yoshifuku, Asuka; Higashi, Yuko; Matsushita, Shigeto; Kawai, Kazuhiro; Kanekura, Takuro

    2013-09-01

    We previously reported the clinical effectiveness of transdermal nicotine patches for the treatment of skin disorders with eosinophilic infiltration such as Kimura's disease, erythema nodosum and eosinophilic pustular folliculitis (EPF). We assessed the efficacy and safety of transdermal nicotine patches for EPF. We treated eight patients with EPF with transdermal nicotine patches and evaluated the treatment response by performing overall lesional assessment. Excellent 77and good responses were obtained in five and one patient(s), respectively. In the other two patients, the lesions remained unchanged. No severe adverse effects were observed. Our results suggest that transdermal nicotine patches may be useful and safe in the treatment of EPF. © 2013 Japanese Dermatological Association.

  19. Immunoisolation Patch System for Cellular Transplantation

    NASA Technical Reports Server (NTRS)

    Wang, Taylor G. (Inventor)

    2014-01-01

    An immunoisolation patch system, and particularly a patch system comprising multiple immunoisolation microcapsules, each encapsulating biological material such as cells for transplantation, which can be used in the prophylactic and therapeutic treatment of disease in large animals and humans without the need for immunosuppression.

  20. Predator-Prey Interactions Shape Thermal Patch Use in a Newt Larvae-Dragonfly Nymph Model

    PubMed Central

    Gvoždík, Lumír; Černická, Eva; Van Damme, Raoul

    2013-01-01

    Thermal quality and predation risk are considered important factors influencing habitat patch use in ectothermic prey. However, how the predator’s food requirement and the prey’s necessity to avoid predation interact with their respective thermoregulatory strategies remains poorly understood. The recently developed ‘thermal game model’ predicts that in the face of imminent predation, prey should divide their time equally among a range of thermal patches. In contrast, predators should concentrate their hunting activities towards warmer patches. In this study, we test these predictions in a laboratory setup and an artificial environment that mimics more natural conditions. In both cases, we scored thermal patch use of newt larvae (prey) and free-ranging dragonfly nymphs (predators). Similar effects were seen in both settings. The newt larvae spent less time in the warm patch if dragonfly nymphs were present. The patch use of the dragonfly nymphs did not change as a function of prey availability, even when the nymphs were starved prior to the experiment. Our behavioral observations partially corroborate predictions of the thermal game model. In line with asymmetric fitness pay-offs in predator-prey interactions (the ‘life-dinner’ principle), the prey’s thermal strategy is more sensitive to the presence of predators than vice versa. PMID:23755175

  1. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    NASA Technical Reports Server (NTRS)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  2. Perturbation analysis for patch occupancy dynamics

    USGS Publications Warehouse

    Martin, Julien; Nichols, James D.; McIntyre, Carol L.; Ferraz, Goncalo; Hines, James E.

    2009-01-01

    Perturbation analysis is a powerful tool to study population and community dynamics. This article describes expressions for sensitivity metrics reflecting changes in equilibrium occupancy resulting from small changes in the vital rates of patch occupancy dynamics (i.e., probabilities of local patch colonization and extinction). We illustrate our approach with a case study of occupancy dynamics of Golden Eagle (Aquila chrysaetos) nesting territories. Examination of the hypothesis of system equilibrium suggests that the system satisfies equilibrium conditions. Estimates of vital rates obtained using patch occupancy models are used to estimate equilibrium patch occupancy of eagles. We then compute estimates of sensitivity metrics and discuss their implications for eagle population ecology and management. Finally, we discuss the intuition underlying our sensitivity metrics and then provide examples of ecological questions that can be addressed using perturbation analyses. For instance, the sensitivity metrics lead to predictions about the relative importance of local colonization and local extinction probabilities in influencing equilibrium occupancy for rare and common species.

  3. Adolescents' experiences using the contraceptive patch versus pills.

    PubMed

    Sucato, Gina S; Land, Stephanie R; Murray, Pamela J; Cecchini, Reena; Gold, Melanie A

    2011-08-01

    To compare use of the weekly transdermal contraceptive patch (patch) with daily combined hormonal contraceptive pills (pills) in adolescents. Prospective longitudinal study of adolescents' self-selected (non-randomized) use of the patch or pills. Urban, university hospital-affiliated, adolescent outpatient clinic. 13-22-year-old female adolescents seeking hormonal contraception, 40 who chose the patch and 40 who chose pills. Data were collected via self-report on paper questionnaires at three-cycle intervals for a total of up to nine cycles. Method continuation, perfect use, method satisfaction, quality of life, and side effects, including menstrual changes and perceived mood changes. After nine cycles, 38% of patch users and 60% of pill users were still using the method they had chosen at enrollment. There were no significant differences between the groups in self-reported perfect use. No differences were found in quality of life or side effects. Both patch and pill users noted menses became lighter and more predictable and reported decreased depression prior to their menses; only the pill group reported improvement in premenstrual anger. Method satisfaction was similar in both groups except patch users were more likely to report that their contraceptive method improved normal daily activities. Despite apparent advantages of the patch over the pill, adolescents using both methods continue to face challenges achieving perfect and sustained contraceptive use. 2011 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  4. A smart composite patch for the repair of aircraft structures

    NASA Astrophysics Data System (ADS)

    Wakha, Kelah; Samuel, Paul; Pines, Darryll J.

    2005-05-01

    Recent interest in bonded composite patch repair technology for aerospace systems is because this method can be carried out at a reduced cost and time and can easily be applied to complex geometric structures. This paper details the development of a dual stiffness/energy sensor for monitoring the integrity of a composite patch used to repair an aluminum structural component. The smart sensor has the ability to predict the elastic field of a given host structure based on the strain state of two sub-sensors integrated into the structure. The present study shows the possibility of using the sensor to deduce the local instantaneous host stiffness. Damaged structures are characterized by a reduction in their elastic stiffness that evolve from microstructural defects. A local smart sensor can be developed to sense the local average properties on a host. In this paper, sensors are attached to a structure and a modified Eshelby's equivalent inclusion method is used to derive the elastic properties of the host. An analytical derivation and a sensitivity analysis for the quasistatic application is given in a papers by Majed, Dasgupta, Kelah and Pines. A summary of the derivation of the dynamic Eshelby tensor is presented. This is of importance because damage detection in structures undergoing vibratory and other motions present a greater challenge than those in quasistatic motion. An in-situ health monitoring active sensor system for a real structure (an aluminum plate with an attached repair patch) under close-to real lifecycle loading conditions is developed. The detection of the onset of any damage to the structure as well as the repair patch and the subsequent monitoring of the growth of this damage constitute important goals of the system. Both experimental and finite element methods were applied. Experimental results are presented for tests of the aluminum plate with the repair patch under monotonic quasi-static and dynamic loading vibratory conditions. In summary, the

  5. Evaluation of a mucoadhesive buccal patch for delivery of peptides: in vitro screening of bioadhesion.

    PubMed

    Li, C; Bhatt, P P; Johnston, T P

    1998-10-01

    We have assessed the bioadhesive properties of several different mucoadhesive buccal patches. The patches consisted of custom coformulations of silicone polymers and Carbopol 974P. The contact angle of water was measured for each of the test formulations, using an ophthalmic shadow scope. The corresponding work of adhesion between the water and the patches (W1), and between the patches and freshly-excised rabbit buccal mucosa (W2) was then calculated, using a modification of Dupre's equation. The bioadhesive strength between the patches and excised rabbit buccal mucosa was also assessed. The results of the contact-angle measurements indicated that the contact angle decreased with an increase in the amount of Carbopol in the formulation. Additionally, the calculated values of both W1 and W2 increased with an increase in the amount of Carbopol in the buccal-patch formulations. A correlation (r not equal to 0.9808) was found between the measured contact angle and the calculated values for W2. The direct measurement of the force required to separate a buccal patch from excised rabbit buccal mucosa with the INSTRON demonstrated that the adhesive strength increased with an increase in the amount of Carbopol. This preliminary study has shown that the measurement of contact angles alone may provide a useful technique for estimating the work of adhesion, and may serve as a convenient and rapid screening procedure to identify potential mucoadhesive buccal-patch formulations.

  6. Generic patches containing fentanyl: In vitro equivalence and abuse deterrent evaluation according to EMA and FDA guidelines.

    PubMed

    Padula, Cristina; Pescina, Silvia; Nicoli, Sara; Santi, Patrizia

    2018-02-15

    The aim of this work was to characterize in vitro and ex vivo the performances of Durogesic and of two bioequivalent generic products, by evaluating: (a) fentanyl release; (b) fentanyl permeation across porcine skin and (c) fentanyl ease of extraction. Additional characteristics studied are the effect of temperature and skin integrity, applied individually or combined, to check a possible synergism. The two generic patches resulted equivalent to the originator according to the new Guideline. Nevertheless, the same data reported in a different way, i.e. considering the total amount of drug permeated from the whole patch over the application time, highlight differences among the patches. The additional tests performed showed that skin integrity does not represent a barrier for fentanyl permeation across the skin, regardless of the type and complexity of the patch. The effect of temperature resulted critical for two out of three patches, probably due to the different composition and to the different structure. The combination of skin damage and elevated temperature did not produce a synergistic effect. Fentanyl extraction was different for the different products and variable according to the conditions used. The results reported in the present work underline the influence of patch composition and complexity on fentanyl extraction, release and skin permeation, in particular in conditions that can be critical, such as elevated temperature. In particular, the effect of critical variables, such as skin integrity and temperature, should be addressed to in the development of a new or new generic patch and new discriminant tests should be developed. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Boolean Operations with Prism Algebraic Patches

    PubMed Central

    Bajaj, Chandrajit; Paoluzzi, Alberto; Portuesi, Simone; Lei, Na; Zhao, Wenqi

    2009-01-01

    In this paper we discuss a symbolic-numeric algorithm for Boolean operations, closed in the algebra of curved polyhedra whose boundary is triangulated with algebraic patches (A-patches). This approach uses a linear polyhedron as a first approximation of both the arguments and the result. On each triangle of a boundary representation of such linear approximation, a piecewise cubic algebraic interpolant is built, using a C1-continuous prism algebraic patch (prism A-patch) that interpolates the three triangle vertices, with given normal vectors. The boundary representation only stores the vertices of the initial triangulation and their external vertex normals. In order to represent also flat and/or sharp local features, the corresponding normal-per-face and/or normal-per-edge may be also given, respectively. The topology is described by storing, for each curved triangle, the two triples of pointers to incident vertices and to adjacent triangles. For each triangle, a scaffolding prism is built, produced by its extreme vertices and normals, which provides a containment volume for the curved interpolating A-patch. When looking for the result of a regularized Boolean operation, the 0-set of a tri-variate polynomial within each such prism is generated, and intersected with the analogous 0-sets of the other curved polyhedron, when two prisms have non-empty intersection. The intersection curves of the boundaries are traced and used to decompose each boundary into the 3 standard classes of subpatches, denoted in, out and on. While tracing the intersection curves, the locally refined triangulation of intersecting patches is produced, and added to the boundary representation. PMID:21516262

  8. Origin-Dependent Inverted-Repeat Amplification: Tests of a Model for Inverted DNA Amplification

    PubMed Central

    Brewer, Bonita J.; Payen, Celia; Di Rienzi, Sara C.; Higgins, Megan M.; Ong, Giang; Dunham, Maitreya J.; Raghuraman, M. K.

    2015-01-01

    DNA replication errors are a major driver of evolution—from single nucleotide polymorphisms to large-scale copy number variations (CNVs). Here we test a specific replication-based model to explain the generation of interstitial, inverted triplications. While no genetic information is lost, the novel inversion junctions and increased copy number of the included sequences create the potential for adaptive phenotypes. The model—Origin-Dependent Inverted-Repeat Amplification (ODIRA)—proposes that a replication error at pre-existing short, interrupted, inverted repeats in genomic sequences generates an extrachromosomal, inverted dimeric, autonomously replicating intermediate; subsequent genomic integration of the dimer yields this class of CNV without loss of distal chromosomal sequences. We used a combination of in vitro and in vivo approaches to test the feasibility of the proposed replication error and its downstream consequences on chromosome structure in the yeast Saccharomyces cerevisiae. We show that the proposed replication error—the ligation of leading and lagging nascent strands to create “closed” forks—can occur in vitro at short, interrupted inverted repeats. The removal of molecules with two closed forks results in a hairpin-capped linear duplex that we show replicates in vivo to create an inverted, dimeric plasmid that subsequently integrates into the genome by homologous recombination, creating an inverted triplication. While other models have been proposed to explain inverted triplications and their derivatives, our model can also explain the generation of human, de novo, inverted amplicons that have a 2:1 mixture of sequences from both homologues of a single parent—a feature readily explained by a plasmid intermediate that arises from one homologue and integrates into the other homologue prior to meiosis. Our tests of key features of ODIRA lend support to this mechanism and suggest further avenues of enquiry to unravel the origins of

  9. Origin-Dependent Inverted-Repeat Amplification: Tests of a Model for Inverted DNA Amplification.

    PubMed

    Brewer, Bonita J; Payen, Celia; Di Rienzi, Sara C; Higgins, Megan M; Ong, Giang; Dunham, Maitreya J; Raghuraman, M K

    2015-12-01

    DNA replication errors are a major driver of evolution--from single nucleotide polymorphisms to large-scale copy number variations (CNVs). Here we test a specific replication-based model to explain the generation of interstitial, inverted triplications. While no genetic information is lost, the novel inversion junctions and increased copy number of the included sequences create the potential for adaptive phenotypes. The model--Origin-Dependent Inverted-Repeat Amplification (ODIRA)-proposes that a replication error at pre-existing short, interrupted, inverted repeats in genomic sequences generates an extrachromosomal, inverted dimeric, autonomously replicating intermediate; subsequent genomic integration of the dimer yields this class of CNV without loss of distal chromosomal sequences. We used a combination of in vitro and in vivo approaches to test the feasibility of the proposed replication error and its downstream consequences on chromosome structure in the yeast Saccharomyces cerevisiae. We show that the proposed replication error-the ligation of leading and lagging nascent strands to create "closed" forks-can occur in vitro at short, interrupted inverted repeats. The removal of molecules with two closed forks results in a hairpin-capped linear duplex that we show replicates in vivo to create an inverted, dimeric plasmid that subsequently integrates into the genome by homologous recombination, creating an inverted triplication. While other models have been proposed to explain inverted triplications and their derivatives, our model can also explain the generation of human, de novo, inverted amplicons that have a 2:1 mixture of sequences from both homologues of a single parent--a feature readily explained by a plasmid intermediate that arises from one homologue and integrates into the other homologue prior to meiosis. Our tests of key features of ODIRA lend support to this mechanism and suggest further avenues of enquiry to unravel the origins of interstitial

  10. Patch testing with hair cosmetic series in Europe: a critical review and recommendation.

    PubMed

    Uter, Wolfgang; Bensefa-Colas, Lynda; Frosch, Peter; Giménez-Arnau, Ana; John, Swen M; Lepoittevin, Jean-Pierre; Lidén, Carola; White, Ian R; Duus Johansen, Jeanne

    2015-08-01

    Many key ingredients of hair cosmetics (in particular, dyes, bleaches, and hair-styling agents) are potent (strong to extreme) contact allergens. Some heterogeneity is apparent from published results concerning the range of allergens for which patch testing is important. The objective of the present review was to collect information on the current practice of using 'hair cosmetic series', and discuss this against the background of evidence concerning consumer/professional exposure and regulatory aspects to finally derive a recommendation for a 'European hair cosmetic series'. The methods involved (i) a survey targeting all members of the COST action 'StanDerm' (TD1206) consortium, (ii) analysis of data in the database of the European Surveillance System on Contact Allergies (ESSCA), and (iii) literature review. Information from 19 European countries was available, partly from national networks, and partly from one or several departments of dermatology or, occasionally, occupational medicine. Apart from some substances being tested only in single departments, a broad overlap regarding 'important' allergens was evident. Some of the substances are no longer permitted for use in cosmetics (Annex II of the Cosmetics Regulation). An up-to-date 'European hair cosmetics series', as recommended in the present article, should (i) include broadly used and/or potent contact allergens, (ii) eliminate substances of only historical concern, and (iii) be continually updated as new evidence emerges. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Identifying preferred habitats of samango monkeys (Cercopithecus (nictitans) mitis, erythrarchus) through patch use.

    PubMed

    Emerson, Sara E; Brown, Joel S

    2013-10-26

    To examine habitat preferences of two groups of samango monkeys (Cercopithecus (nictitans) mitis erythrarchus) in the Soutpansberg, South Africa, we used experimental food patches in fragments of tall forest and in bordering secondary growth short forest. Additionally, to test for the impacts of group cohesion and movement on habitat use, we tested for the interaction of space and time in our analyses of foraging intensity in the experimental food patches placed throughout the home ranges of the two groups. We expected the monkeys to harvest the most from patches in tall forest habitats and the least from patches in short forest. Further, because the monkeys move through their habitats in groups, we expected to see group cohesion effects illustrated by daily spatial variation in the monkeys' use of widespread foraging grids. In the forest height experiments, the two groups differed in their foraging responses, with 8% greater foraging overall for one group. However, forest height did not significantly impact foraging in either group, meaning that, given feeding opportunities, samango monkeys are able to utilize secondary growth forest. For one group, missed opportunity costs of staying with the group appeared through the statistical interaction of day with foraging location (the monkeys did not always spread out to take advantage of all available food patches). In several subsequent experiments in widespread grids, significant daily spatial variation in foraging occurred, pointing to spatial cohesion during group movement as likely being an important predictor of habitat use. For an individual social forager, staying with the group may be more important than habitat type in driving habitat selection. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Smart patch piezoceramic actuator issues

    NASA Technical Reports Server (NTRS)

    Griffin, Steven F.; Denoyer, Keith K.; Yost, Brad

    1993-01-01

    The Phillips Laboratory is undertaking the challenge of finding new and innovative ways to integrate sensing, actuation, and the supporting control and power electronics into a compact self-contained unit to provide vibration suppression for a host structure. This self-contained unit is commonly referred to as a smart patch. The interfaces to the smart patch will be limited to standard spacecraft power and possibly a communications line. The effort to develop a smart patch involves both contractual and inhouse programs which are currently focused on miniaturization of the electronics associated with vibrational control using piezoceramic sensors and actuators. This paper is comprised of two distinct parts. The first part examines issues associated with bonding piezoceramic actuators to a host structure. Experimental data from several specimens with varying flexural stiffness are compared to predictions from two piezoelectric/substructure coupling models, the Blocked Force Model and the Uniform Strain Model with Perfect Bonding. The second part of the paper highlights a demonstration article smart patch created using the insights gained from inhouse efforts at the Phillips Laboratory. This demonstration article has self contained electronics on the same order of size as the actuator powered by a voltage differential of approximately 32 volts. This voltage is provided by four rechargeable 8 volt batteries.

  13. A pliable electroporation patch (ep-Patch) for efficient delivery of nucleic acid molecules into animal tissues with irregular surface shapes.

    PubMed

    Wei, Zewen; Huang, Yuanyu; Zhao, Deyao; Hu, Zhiyuan; Li, Zhihong; Liang, Zicai

    2015-01-05

    Delivery of nucleic acids into animal tissues by electroporation is an appealing approach for various types of gene therapy, but efficiency of existing methodsis not satisfactory. Here we present the validation of novel electroporation patch (ep-Patch) for efficient delivery of DNA and siRNA into mouse tissues. Using micromachining technology, closely spaced gold electrodes were made on the pliable parylene substrate to form a patch-like electroporation metrics. It enabled large coverage of the target tissues and close surface contact between the tissues and electrodes, thus providing a uniform electric field to deliver nucleic acids into tissues, even beneath intact skin. Using this ep-Patch for efficiently delivery of both DNA and siRNA, non-invasive electroporation of healthy mouse muscle tissue was successfully achieved. Delivery of these nucleic acids was performed to intact tumors with satisfactory results. Silencing of tumor genes using the ep-Patch was also demonstrated on mice. This pliable electroporation patch method constitutes a novel way of in vivo delivery of siRNA and DNA to certain tissues or organs to circumvent the disadvantages of existing methodologies for in vivo delivery of nucleic acid molecules.

  14. Test-retest repeatability of child's respiratory symptoms and perceived indoor air quality - comparing self- and parent-administered questionnaires.

    PubMed

    Lampi, Jussi; Ung-Lanki, Sari; Santalahti, Päivi; Pekkanen, Juha

    2018-02-09

    Questionnaires can be used to assess perceived indoor air quality and symptoms in schools. Questionnaires for primary school aged children have traditionally been parent-administered, but self-administered questionnaires would be easier to administer and may yield as good, if not better, information. Our aim was to compare the repeatability of self- and parent-administered indoor air questionnaires designed for primary school aged pupils. Indoor air questionnaire with questions on child's symptoms and perceived indoor air quality in schools was sent to parents of pupils aged 7-12 years in two schools and again after two weeks. Slightly modified version of the questionnaire was administered to pupils aged 9-12 years in another two schools and repeated after a week. 351 (52%) parents and 319 pupils (86%) answered both the first and the second questionnaire. Test-retest repeatability was assessed with intra-class correlation (ICC) and Cohen's kappa coefficients (k). Test-retest repeatability was generally between 0.4-0.7 (ICC; k) in both self- and parent-administered questionnaire. In majority of the questions on symptoms and perceived indoor air quality test-retest repeatability was at the same level or slightly better in self-administered compared to parent-administered questionnaire. Agreement of self- and parent administered questionnaires was generally < 0.4 (ICC; k) in reported symptoms and 0.4-0.6 (ICC; k) in perceived indoor air quality. Children aged 9-12 years can give as, or even more, repeatable information about their respiratory symptoms and perceived indoor air quality than their parents. Therefore, it may be possible to use self-administered questionnaires in future studies also with children.

  15. Determination of resilient properties of unbound materials with repeated load triaxial and diametral test systems.

    DOT National Transportation Integrated Search

    1981-12-01

    Repeated load diametral test systems are experiencing increased use to determine resilient properties of asphalt concrete and admixture stabilized materials; they have not been used extensively to determine the resilient properties of unbound materia...

  16. Enhanced Stability of Inactivated Influenza Vaccine Encapsulated in Dissolving Microneedle Patches

    PubMed Central

    Chu, Leonard Y.; Ye, Ling; Dong, Ke; Compans, Richard W.; Yang, Chinglai; Prausnitz, Mark R.

    2015-01-01

    Purpose This study tested the hypothesis that encapsulation of influenza vaccine in microneedle patches increases vaccine stability during storage at elevated temperature. Methods Whole inactivated influenza virus vaccine (A/Puerto Rico/8/34) was formulated into dissolving microneedle patches and vaccine stability was evaluated by in vitro and in vivo assays of antigenicity and immunogenicity after storage for up to 3 months at 4, 25, 37 and 45°C. Results While liquid vaccine completely lost potency as determined by hemagglutination (HA) activity within 1–2 weeks outside of refrigeration, vaccine in microneedle patches lost 40–50% HA activity during or shortly after fabrication, but then had no significant additional loss of activity over 3 months of storage, independent of temperature. This level of stability required reduced humidity by packaging with desiccant, but was not affected by presence of oxygen. This finding was consistent with additional stability assays, including antigenicity of the vaccine measured by ELISA, virus particle morphological structure captured by transmission electron microscopy and protective immune responses by immunization of mice in vivo. Conclusions These data show that inactivated influenza vaccine encapsulated in dissolving microneedle patches has enhanced stability during extended storage at elevated temperatures. PMID:26620313

  17. Correlation between afferent rearrangements and behavioral deficits after local excitotoxic insult in the mammalian vestibule: a rat model of vertigo symptoms.

    PubMed

    Gaboyard-Niay, Sophie; Travo, Cécile; Saleur, Aurélie; Broussy, Audrey; Brugeaud, Aurore; Chabbert, Christian

    2016-10-01

    Damage to inner ear afferent terminals is believed to result in many auditory and vestibular dysfunctions. The sequence of afferent injuries and repair, as well as their correlation with vertigo symptoms, remains poorly documented. In particular, information on the changes that take place at the primary vestibular endings during the first hours following a selective insult is lacking. In the present study, we combined histological analysis with behavioral assessments of vestibular function in a rat model of unilateral vestibular excitotoxic insult. Excitotoxicity resulted in an immediate but transient alteration of the balance function that was resolved within a week. Concomitantly, vestibular primary afferents underwent a sequence of structural changes followed by spontaneous repair. Within the first two hours after the insult, a first phase of pronounced vestibular dysfunction coincided with extensive swelling of afferent terminals. In the next 24 h, a second phase of significant but incomplete reduction of the vestibular dysfunction was accompanied by a resorption of swollen terminals and fiber retraction. Eventually, within 1 week, a third phase of complete balance restoration occurred. The slow and progressive withdrawal of the balance dysfunction correlated with full reconstitution of nerve terminals. Competitive re-innervation by afferent and efferent terminals that mimicked developmental synaptogenesis resulted in full re-afferentation of the sensory epithelia. By deciphering the sequence of structural alterations that occur in the vestibule during selective excitotoxic impairment, this study offers new understanding of how a vestibular insult develops in the vestibule and how it governs the heterogeneity of vertigo symptoms. © 2016. Published by The Company of Biologists Ltd.

  18. Fentanyl Transdermal Patch

    MedlinePlus

    Fentanyl patches are used to relieve severe pain in people who are expected to need pain medication ... and who cannot be treated with other medications. Fentanyl is in a class of medications called opiate ( ...

  19. Selegiline Transdermal Patch

    MedlinePlus

    ... patch from direct heat such as heating pads, electric blankets, heat lamps, saunas, hot tubs, and heated ... may make you drowsy. Do not drive a car or operate machinery until you know how this ...

  20. Nicotine Transdermal Patch

    MedlinePlus

    ... patches are used to help people stop smoking cigarettes. They provide a source of nicotine that reduces ... cause harm to the fetus.do not smoke cigarettes or use other nicotine products while using nicotine ...

  1. Testosterone Transdermal Patch

    MedlinePlus

    ... one else can use it accidentally or on purpose. Keep track of how many patches are left ... to your pharmacist or contact your local garbage/recycling department to learn about take-back programs in ...

  2. Nitroglycerin Transdermal Patch

    MedlinePlus

    ... vasodilators. It works by relaxing the blood vessels so that the heart does not need to work ... patches may be applied in slightly different ways, so be sure to follow the directions included with ...

  3. Current usage and future directions for the bovine pericardial patch.

    PubMed

    Li, Xin; Guo, Yuanyuan; Ziegler, Kenneth R; Model, Lynn S; Eghbalieh, Sammy D D; Brenes, Robert A; Kim, Susun T; Shu, Chang; Dardik, Alan

    2011-05-01

    Bovine pericardium (BP) is widely used in surgery and is commonly used as a patch after arteriotomy in cardiovascular surgery. BP patches have several advantages compared with prosthetic patches, including superior biocompatability, easy handling, less suture line bleeding, and possibly reduced rates of infection. These advantages of BP have led to its common use during carotid endarterectomy (CEA). However, long-term clinical results reported after CEA have suggested several issues that may be related to the patch, including restenosis, pseudoaneurysm formation, infection, fibrosis, calcification, and thrombosis. These complications may diminish the long-term efficacy of CEA and suggest potential areas for improvement of surgical patches. Understanding the mechanisms by which BP heals after patch angioplasty may lead to next generation tissue-engineered patches. Published by Elsevier Inc.

  4. CAG repeat testing of androgen receptor polymorphism: is this necessary for the best clinical management of hypogonadism?

    PubMed

    Francomano, Davide; Greco, Emanuela A; Lenzi, Andrea; Aversa, Antonio

    2013-10-01

    It is controversial whether or not testing the length of the androgen receptor polymorphism in clinical practice is useful for correct diagnosis and treatment of hypogonadism. To describe the molecular and clinical implications of testing the length of the androgen receptor polymorphism for treatment of hypogonadism in both male and female subjects. A systematic Medline search was conducted using several terms related to and including the terms "androgen receptor," "CAG-repeat polymorphism," "male hypogonadism," "female hypogonadism," and "neurodegenerative disease." Clinical evidence that demonstrates the importance of CAG repeat number investigation in male and female hypogonadism. A thorough review of the clinical utility of CAG repeat polymorphism investigation in men and women with hypogonadism is presented. The role of AR CAG repeat number investigation in hypogonadism (male and female) is not yet established in the clinical practice. In both sexes, a role during clinical management of hormonal replacement therapies may be hypothesized, but the CAG repeat number's relationship with the presence or absence of hypogonadal symptoms remains unclear. Pharmacogenomic investigations of the AR polymorphism may be a future option to tailor testosterone titration individually and to better identify subjects as potentially more or less responsive to treatments; also, investigation may be important to individually predict beneficial and side effects in special subpopulations, specifically, obese men and postmenopausal women. © 2013 International Society for Sexual Medicine.

  5. Fentanyl Patch Can Be Deadly to Children

    MedlinePlus

    ... Products For Consumers Home For Consumers Consumer Updates Fentanyl Patch Can Be Deadly to Children Share Tweet ... from accidental exposure to a skin patch containing fentanyl, a powerful pain reliever. As a result of ...

  6. Development of microcomputer-based mental acuity tests for repeated-measures studies

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.; Wilkes, R. L.; Baltzley, D. R.; Fowlkes, J. E.

    1990-01-01

    The purpose of this report is to detail the development of the Automated Performance Test System (APTS), a computer battery of mental acuity tests that can be used to assess human performance in the presence of toxic elements and environmental stressors. There were four objectives in the development of APTS. First, the technical requirements for developing APTS followed the tenets of the classical theory of mental tests which requires that tests meet set criteria like stability and reliability (the lack of which constitutes insensitivity). To be employed in the study of the exotic conditions of protracted space flight, a battery with multiple parallel forms is required. The second criteria was for the battery to have factorial multidimensionality and the third was for the battery to be sensitive to factors known to compromise performance. A fourth objective was for the tests to converge on the abilities entailed in mission specialist tasks. A series of studies is reported in which candidate APTS tests were subjected to an examination of their psychometric properties for repeated-measures testing. From this work, tests were selected that possessed the requisite metric properties of stability, reliability, and factor richness. In addition, studies are reported which demonstrate the predictive validity of the tests to holistic measures of intelligence.

  7. Does Repeated Testing Impact Concordance Between Genital and Self-Reported Sexual Arousal in Women?

    PubMed

    Velten, Julia; Chivers, Meredith L; Brotto, Lori A

    2018-04-01

    Women show a substantial variability in their genital and subjective responses to sexual stimuli. The level of agreement between these two aspects of response is termed sexual concordance and has been increasingly investigated because of its implications for understanding models of sexual response and as a potential endpoint in clinical trials of treatments to improve women's sexual dysfunction. However, interpreting changes in sexual concordance may be problematic because, to date, it still is unclear how repeated testing itself influences sexual concordance in women. We are aware of only one study that evaluated temporal stability of concordance in women, and it found no evidence of stability. However, time stability would be necessary for arguing that concordance is a stable individual difference. The main goal of this study was to investigate the test-retest reliability of sexual concordance in a sample of 30 women with sexual difficulties. Using hierarchical linear modeling, we found that sexual concordance was not influenced by repeated testing 12 weeks later, but showed test-retest reliability suggesting temporal stability. Our findings support the hypothesis that sexual concordance is a relatively stable individual difference and that changes in sexual concordance after treatment or experimental conditions could, therefore, be attributed to effects of those conditions.

  8. Conductive polymer nanotube patch for fast and controlled ex vivo transdermal drug delivery.

    PubMed

    Nguyen, Thao M; Lee, Sebin; Lee, Sang Bok

    2014-10-01

    To uptake and release hydrophilic model drugs and insulin in a novel conductive polymer (CP) nanotube transdermal patch. The externally controlled transdermal delivery of model drugs and insulin were tested ex vivo and results were compared with CP films. The unique intrinsic properties of CPs provide electrostatic interaction between the model drugs and polymer backbone. When a pulsed potential was applied, the drug delivery release profile mimics that of injection delivery. With a constant potential applied, the release rate constants of the patch system were up to three-times faster than the control (0 V) and released approximately 80% more drug molecules over 24 h. The CP nanotube transdermal patch represents a new and promising drug method, specifically for hydrophilic molecules, which have been a large obstacle for conventional transdermal drug delivery systems.

  9. Development of a self-stressing NiTiNb shape memory alloy (SMA)/fiber reinforced polymer (FRP) patch

    NASA Astrophysics Data System (ADS)

    El-Tahan, M.; Dawood, M.; Song, G.

    2015-06-01

    The objective of this research is to develop a self-stressing patch using a combination of shape memory alloys (SMAs) and fiber reinforced polymer (FRP) composites. Prestressed carbon FRP patches are emerging as a promising alternative to traditional methods to repair cracked steel structures and civil infrastructure. However, prestressing these patches typically requires heavy and complex fixtures, which is impractical in many applications. This paper presents a new approach in which the prestressing force is applied by restraining the shape memory effect of NiTiNb SMA wires. The wires are subsequently embedded in an FRP overlay patch. This method overcomes the practical challenges associated with conventional prestressing. This paper presents the conceptual development of the self-stressing patch with the support of experimental observations. The bond between the SMA wires and the FRP is evaluated using pull-out tests. The paper concludes with an experimental study that evaluates the patch response during activation subsequent monotonic tensile loading. The results demonstrate that the self-stressing patch with NiTiNb SMA is capable of generating a significant prestressing force with minimal tool and labor requirements.

  10. Lipid-glass adhesion in giga-sealed patch-clamped membranes.

    PubMed

    Opsahl, L R; Webb, W W

    1994-01-01

    Adhesion between patch-clamped lipid membranes and glass micropipettes is measured by high contrast video imaging of the mechanical response to the application of suction pressure across the patch. The free patch of membrane reversibly alters both its contact angle and radius of curvature on pressure changes. The assumption that an adhesive force between the membrane and the pipette can sustain normal tension up to a maximum Ta at the edge of the free patch accounts for the observed mechanical responses. When the normal component of the pressure-induced membrane tension exceeds Ta membrane at the contact point between the free patch and the lipid-glass interface is pulled away from the pipette wall, resulting in a decreased radius of curvature for the patch and an increased contact angle. Measurements of the membrane radius of curvature as a function of the suction pressure and pipette radius determine line adhesion tensions Ta which range from 0.5 to 4.0 dyn/cm. Similar behavior of patch-clamped cell membranes implies similar adhesion mechanics.

  11. Memory deficits with intact cognitive control in the methylazoxymethanol acetate (MAM) exposure model of neurodevelopmental insult.

    PubMed

    O'Reilly, Kally C; Perica, Maria I; Fenton, André A

    2016-10-01

    Cognitive impairments are amongst the most debilitating deficits of schizophrenia and the best predictor of functional outcome. Schizophrenia is hypothesized to have a neurodevelopmental origin, making animal models of neurodevelopmental insult important for testing predictions that early insults will impair cognitive function. Rats exposed to methylazoxymethanol acetate (MAM) at gestational day 17 display morphological, physiological and behavioral abnormalities relevant to schizophrenia. Here we investigate the cognitive abilities of adult MAM rats. We examined brain activity in MAM rats by histochemically assessing cytochrome oxidase enzyme activity, a metabolic marker of neuronal activity. To assess cognition, we used a hippocampus-dependent two-frame active place avoidance paradigm to examine learning and spatial memory, as well as cognitive control and flexibility using the same environment and evaluating the same set of behaviors. We confirmed that adult MAM rats have altered hippocampal morphology and brain function, and that they are hyperactive in an open field. The latter likely indicates MAM rats have a sensorimotor gating deficit that is common to many animal models used for schizophrenia research. On first inspection, cognitive control seems impaired in MAM rats, indicated by more errors during the two-frame active place avoidance task. Because MAM rats are hyperactive throughout place avoidance training, we considered the possibility that the hyperlocomotion may account for the apparent cognitive deficits. These deficits were reduced on the basis of measures of cognitive performance that account for motor activity differences. However, though other aspects of memory are intact, the ability of MAM rats to express trial-to-trial memory is delayed compared to control rats. These findings suggest that spatial learning and cognitive abilities are largely intact, that the most prominent cognitive deficit is specific to acquiring memory in the MAM

  12. Corridor Length and Patch Colonization by a Butterfly, Junonia coenia

    Treesearch

    Nick Haddad

    2000-01-01

    Corridors have been proposed to reduce isolation and increase population persistence in fragmented landscapes, yet little research has evaluated the types of landscapes in which corridors will be most effective. I tested the hypothesis that corridors increase patch colonization by a butterfly, Junonia coenia, regardless of the butterfly's...

  13. EFFECT OF HYDROPHILIC AND HYDROPHOBIC POLYMER ON IN VITRO DISSOLUTION AND PERMEATION OF BISOPROLOL FUMARATE THROUGH TRANSDERMAL PATCH.

    PubMed

    Shabbir, Maryam; Ali, Sajid; Raza, Moosa; Sharif, Ali; Akhtar, Furoan Muhammad; Manan, Abdul; Fazli, Ali Raza; Younas, Neelofar; Manzoor, Iqra

    2017-01-01

    A matrix transdermal patch of bisoprolol fumarate was formulated with different concentrations of Eudragit RS 100 and Methocel E5 with PEG 400 as plasticizer by solvent evaporation technique. Tween 80 was added to the optimized patch to evaluate the effect of permeation enhancer at different concentration through the excised rabbit's skin. The patches were analyzed for weight variation, drug content, swelling index, erosion studies, moisture content, moisture uptake, water vapor transmission rate (WVTR) and water vapor permeability (WVP). In vitro dissolution test was carried out in USP dissolution apparatus V to select the optimized formulation. In vitr skin permeation studies were done in Franz diffusion cell using rabbit skin as a model membrane. The cumulative drug release and flux were determined to compare the result of test patches with a control patch. The greatest enhancement ratio (ER) was obtained in F03-PE with 30% Tween 80. F03-PE seemed to follow zero order kinetics with super case II mechanism of drug release. Statistical ANOVA suggested that there was a significant difference in formulations, steady flux and cumulative permeation rate at different Tween 80 concentrations.

  14. Current usage and future directions for the bovine pericardial patch

    PubMed Central

    Li, Xin; Guo, Yuanyuan; Ziegler, Kenneth; Model, Lynn; Eghbalieh, Sammy D. D.; Brenes, Robert; Kim, Susun; Shu, Chang; Dardik, Alan

    2010-01-01

    Bovine pericardium is widely used in surgery and is commonly used for a patch after arteriotomy during cardiovascular surgery. Bovine pericardial patches have several advantages compared to prosthetic patches, including superior biocompatability, easy handling, less suture line bleeding and possibly reduced rates of infection. These advantages of bovine pericardium have led to its common use during carotid endarterectomy. However, long-term clinical results reported after carotid endarterectomy have suggested several issues that may be related to the patch including restenosis, pseudoaneurysm formation, infection, fibrosis, calcification and thrombosis. These complications may diminish the long-term efficacy of carotid endarterectomy and suggest potential areas for improvement of surgical patches. Understanding the mechanisms by which bovine pericardium heals after patch angioplasty may lead to next generation tissue engineered patches. PMID:21276709

  15. Lidocaine patches reduce pain in trauma patients with rib fractures.

    PubMed

    Zink, Karen A; Mayberry, John C; Peck, Ellen G; Schreiber, Martin A

    2011-04-01

    Rib fracture pain is notoriously difficult to manage. The lidocaine patch is effective in other pain scenarios with an excellent safety profile. This study assesses the efficacy of lidocaine patches for treating rib fracture pain. A prospectively gathered cohort of patients with rib fracture was retrospectively analyzed for use of lidocaine patches. Patients treated with lidocaine patches were matched to control subjects treated without patches. Subjective pain reports and narcotic use before and after patch placement, or equivalent time points for control subjects, were gathered from the chart. All patients underwent long-term follow-up, including a McGill Pain Questionnaire (MPQ). Twenty-nine patients with lidocaine patches (LP) and 29 matched control subjects (C) were analyzed. During the 24 hours before patch placement, pain scores and narcotic use were similar (LP 5.3, C 4.6, P = 0.19 and LP 51, C 32 mg morphine, P = 0.17). In the 24 hours after patch placement, LP patients had a greater decrease in pain scores (LP 1.2, C 0.0, P = 0.01) with no change in narcotic use (LP -8.4, C 0.5-mg change in morphine, P = 0.25). At 60 days, LP patients had a lower MPQ pain score (LP 7.7, C 12.2, P < 0.01), although only one patient was still using a patch. There was no difference in time to return to baseline activity (LP 73, C 105 days, P = 0.16) and no adverse events. Lidocaine patches are a safe, effective adjunct for rib fracture pain. Lidocaine patches resulted in a sustained reduction in pain, outlasting the duration of therapy.

  16. Feasibility and repeatability of cold and mechanical quantitative sensory testing in normal dogs

    PubMed Central

    Briley, Jessica D.; Williams, Morika D.; Freire, Mila; Griffith, Emily H.; Lascelles, B. Duncan X.

    2015-01-01

    Feasibility and inter-session repeatability of cold and mechanical quantitative sensory testing (QST) were assessed in 24 normal dogs. Cold thermal latencies were evaluated using a thermal probe (0 °C) applied to three pelvic limb sites. Mechanical thresholds were measured using an electronic von Frey anesthesiometer (EVF) and a blunt-probed pressure algometer (PA) applied to the dorsal aspect of the metatarsus. All QST trials were performed with dogs in lateral recumbency. Collection of cold QST data was easy (feasible) in 19/24 (79%) dogs. However, only 18.4%, 18.9% and 13.2% of cold QST trials elicited a response at the medial tibia, third digital pad and plantar metatarsal regions, respectively. Collection of mechanical QST data was easy (feasible) in 20/24 (83%) dogs for both EVF and PA. At consecutive sampling times, approximately 2 weeks apart, the average EVF sensory thresholds were 414 ± 186 g and 379 ± 166 g, respectively, and the average PA sensory thresholds were 1089 ± 414 g and 1028 ± 331 g, respectively. There was no significant difference in inter-session or inter-limb threshold values for either mechanical QST device. The cold QST protocol in this study was achievable, but did not provide consistently quantifiable results. Both mechanical QST devices tested provided repeatable, reliable sensory threshold measurements in normal, client-owned dogs. These findings contribute to the validation of the EVF and PA as tools to obtain repeated QST data over time in dogs to assess somatosensory processing changes. PMID:24268475

  17. An extended patch-dynamic framework for food chains in fragmented landscapes

    PubMed Central

    Liao, Jinbao; Chen, Jiehong; Ying, Zhixia; Hiebeler, David E.; Nijs, Ivan

    2016-01-01

    Habitat destruction, a key determinant of species loss, can be characterized by two components, patch loss and patch fragmentation, where the former refers to the reduction in patch availability, and the latter to the division of the remaining patches. Classical metacommunity models have recently explored how food web dynamics respond to patch loss, but the effects of patch fragmentation have largely been overlooked. Here we develop an extended patch-dynamic model that tracks the patch occupancy of the various trophic links subject to colonization-extinction-predation dynamics by incorporating species dispersal with patch connectivity. We found that, in a simple food chain, species at higher trophic level become extinct sooner with increasing patch loss and fragmentation due to the constraint in resource availability, confirming the trophic rank hypothesis. Yet, effects of fragmentation on species occupancy are largely determined by patch loss, with maximal fragmentation effects occurring at intermediate patch loss. Compared to the spatially explicit simulations that we also performed, the current model with pair approximation generates similar community patterns especially in spatially clustered landscapes. Overall, our extended framework can be applied to model more complex food webs in fragmented landscapes, broadening the scope of existing metacommunity theory. PMID:27608823

  18. Arbitrarily shaped dual-stacked patch antennas: A hybrid FEM simulation

    NASA Technical Reports Server (NTRS)

    Gong, Jian; Volakis, John L.

    1995-01-01

    A dual-stacked patch antenna is analyzed using a hybrid finite element - boundary integral (FE-BI) method. The metallic patches of the antenna are modeled as perfectly electric conducting (PEC) plates stacked on top of two different dielectric layers. The antenna patches may be of any shape and the lower patch is fed by a coaxial cable from underneath the ground plane or by an aperture coupled microstrip line. The ability of the hybrid FEM technique for the stacked patch antenna characterization will be stressed, and the EM coupling mechanism is also discussed with the aid of the computed near field patterns around the patches.

  19. The predatory mite Phytoseiulus persimilis adjusts patch-leaving to own and progeny prey needs.

    PubMed

    Vanas, V; Enigl, M; Walzer, A; Schausberger, P

    2006-01-01

    Integration of optimal foraging and optimal oviposition theories suggests that predator females should adjust patch leaving to own and progeny prey needs to maximize current and future reproductive success. We tested this hypothesis in the predatory mite Phytoseiulus persimilis and its patchily distributed prey, the two-spotted spider mite Tetranychus urticae. In three separate experiments we assessed (1) the minimum number of prey needed to complete juvenile development, (2) the minimum number of prey needed to produce an egg, and (3) the ratio between eggs laid and spider mites left when a gravid P. persimilis female leaves a patch. Experiments (1) and (2) were the pre-requirements to assess the fitness costs associated with staying or leaving a prey patch. Immature P. persimilis needed at least 7 and on average 14+/-3.6 (SD) T. urticae eggs to reach adulthood. Gravid females needed at least 5 and on average 8.5+/-3.1 (SD) T. urticae eggs to produce an egg. Most females left the initial patch before spider mite extinction, leaving prey for progeny to develop to adulthood. Females placed in a low density patch left 5.6+/-6.1 (SD) eggs per egg laid, whereas those placed in a high density patch left 15.8+/-13.7 (SD) eggs per egg laid. The three experiments in concert suggest that gravid P. persimilis females are able to balance the trade off between optimal foraging and optimal oviposition and adjust patch-leaving to own and progeny prey needs.

  20. Microscale nutrient patches produced by zooplankton

    PubMed Central

    Lehman, John T.; Scavia, Donald

    1982-01-01

    Both track autoradiography and grain-density autoradiography show that individual zooplankton create miniature patches of dissolved nutrients and that algae exploit those regions to absorb phosphate. The patches are short lived and can be dispersed artificially by small-scale turbulence. Our data support a simple model of encounters between algae and nutrient plumes produced by swimming zooplankton. PMID:16593218

  1. Hydrogel patches containing triclosan for acne treatment.

    PubMed

    Lee, Tae Wan; Kim, Jin Chul; Hwang, Sung Joo

    2003-11-01

    Adhesive hydrogel patches containing Triclosan (TS) were prepared as an anti-acne dosage form. Sodium polyacrylate and carboxymethylcellulose (sodium salt) were used as matrix polymers, and Al(3+), produced by the reaction of dihydroxy aluminum aminoacetate and L(+)-tartaric acid, was employed as a crosslinking agent for the negatively charged polymers. The crosslinking reactions were done at 25, 40 and 50 degrees C for predetermined time intervals. The semi-solid gels were obtained only when the reaction period was more than 12 h, but the polymer gels were fluidic with a shorter reaction. The swelling ratios increased as the reaction period was prolonged and the reaction temperature increased, indicating that the degree of the crosslinking is proportional to the reaction period and the temperature. On a scanning electron microphotograph, the crosslinked gel exhibited a honeycomb-like structure having pores of a few micrometers. The adhesive force of a patch, which could be easily attached to and peeled off facial skin, was 45.5 gmf and it increased by adding poly acrylic acid into the patch formulations. Propionibacterium acnes (ATCC 6919) growth inhibition area around the patch was not significant on an agar plate when TS content was 0.01 wt.%, but the antibacterial activity was apparent when the content was 0.05 wt.%. In vitro permeation revealed that up to 5 wt.% of Transcutol (TC) content in patch, TC, a permeation enhancer, significantly increased the amount of TS transported into hairless mouse skins but it did not substantially accelerate TS transportation into the receptors of Franz diffusion cells. Since our patches for the treatment of acne was aimed to localize TS into skins, TC content of 5 wt.% seems to be adequate for the dermal delivery of TS. The model patches in this study would be applicable to facial skins for the treatment of acne.

  2. Mating success of males with and without wing patch in Drosophila biarmipes.

    PubMed

    Hegde, S N; Chethan, B K; Krishna, M S

    2005-10-01

    Some males of D. biarmipes--synonym of D. rajasekari and D. raychaudhuri have a black patch on the wing. The patch extends from the apical margin of wing to the third longitudinal vein. Field and laboratory studies have been carried out in D. biarmipes to study role of male's wing patch in mating success. The field study shows that nature favors D. biarmipes males with patch. Although males without patch mated, males with patch have higher mating success suggesting the role of wing patch during courtship. Further, among mating males, males with patch had longer wings than males without patch. During courtship, males with patch oriented and mated faster; performed courtship acts such as tapping, scissoring, vibration, licking and twist dance more times than males without patch in both competitive and non-competitive situations. The results indicate that there is a casual relationship between the presence of wing patch, mating speed and success. Also there is a correlation between presence of wing patch, size of the flies and mating success.

  3. A disposable adhesive patch for stress urinary incontinence.

    PubMed

    North, B B

    1998-04-01

    Stress urinary incontinence (SUI) affects 5 million women in the United States. Current surgical and pharmacological management options are often unsuccessful, forcing many sufferers to rely on bulky and uncomfortable sanitary protection. This study evaluated the safety, efficacy, and acceptability of a small, disposable adhesive patch designed to seal the urethral opening and prevent urine leakage. Thirty-seven women with mild-to-moderate SUI were recruited from a suburban community. Each volunteer participated in a 21-week protocol that included a 1-week qualifying period, 4-week (pretest) control period, 12-week patch-use period, and 4-week (posttest) control period. Patch efficacy was evaluated with quantitative (leakage into sanitary napkin) and qualitative (voiding diary) measures of urine leakage. Symptom questionnaires were also completed. Overall leakage was reduced by 60%, from 1.1 +/- .3 standard error of the mean (SEM) to .44 +/- .11 (SEM) grams of urine per hour. Perception of dryness, measured by voiding diaries, improved 67%, from 13.3 +/- 1.9 (SEM) to 4.3 +/- 0.9 (SEM) leakage episodes per week. Safety evaluation included peri-urethral cytology, urinalysis and urine culture, and vaginal cultures. All measures were unaffected by 3 months of patch use. Acceptability was assessed with questionnaires that measured the impact of patch use on activities of daily living and overall quality of life. Women reported a significant improvement in both measures. All but one volunteer found that the patch was comfortable and were able to place it correctly between the inner labia with written instructions only. The disposable patch significantly reduced urine leakage resulting from SUI in community-based women. Dryness improved significantly, both by measurement of actual leakage and by the subject's perception of dryness. The maturation index of the vestibular tissues showed an increase in the number of superficial cells during patch use. Otherwise, there were

  4. Implementation for wideband applications using UWB fractal patch antenna

    NASA Astrophysics Data System (ADS)

    Kumar, D. Naresh

    2018-04-01

    This paper defines in detail about the diverse fractal patch antenna. Microstrip patch antennas has evolved in the field of research and development extending its impact across wide range of applications. A combination of patch antenna with fractal patterns has become a tryout to outspread it further. Because of its low profile nature patch antennas have added to a lot of prominence. Apart from have this property it can also be renovated further for wide bandwidth (2929 MHz) applications, as it exhibits self-analogous property. This antenna is premeditated on a patch using Sierpinski(4.040 GHz, 6.566 GHz) and Koch fractal geometries respectively. The antenna is designed using HFSS software.

  5. Evaluation of the repeatability of a crude adult indirect Ostertagia ostertagi ELISA and methods of expressing test results.

    PubMed

    Sanchez, J; Dohoo, I R; Markham, F; Leslie, K; Conboy, G

    2002-10-16

    An indirect enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against Ostertagia ostertagi using a crude adult worm antigen was evaluated using serum and milk samples from adult cows, as well as from bulk tank milk. Within and between plate repeatabilities were determined. In addition, the effects of factors such as antigen batch, freezing, preserving of the samples and somatic cell counts (SCCs) of the samples were evaluated. Raw optical densities (ODs) and normalized values were compared using the concordance correlation coefficient (CCC), the coefficient of variation (CV), Bland-Altman plots (BA). Based on raw OD values, there was a high repeatability within a plate (CCC approximately 0.96 and CV<10%). Repeatability between plates was evaluated following normalization of OD values by four methods. Computing normalized values as (OD-Nt)/(Pst-Nt), gave the most repeatable results, with the CCC being approximately 0.95 and the CV approximately 11%. When the OD values were higher than 1.2 and 0.3 for the positive and the negative controls, respectively, none of the normalization methods evaluated provided highly repeatable results and it was necessary to repeat the test. Two batches of the crude antigen preparation were evaluated for repeatability, and no difference was found (CCC=0.96). The use of preservative (bronopol) did not affect test results, nor did freezing the samples for up to 8 months. A significant positive relationship between ELISA OD for milk samples and SCC score was found. Therefore, the use of composite milk samples, which have less variable SCC than samples taken from each quarter, would be more suitable when the udder health status is unknown. The analytical methods used to evaluate repeatability provided a practical way to select among normalization procedures.

  6. Measuring wearing times of glasses and ocular patches using a thermosensor device from orthodontics.

    PubMed

    Januschowski, Kai; Bechtold, Till E; Schott, Timm C; Huelber-Januschowski, Maren S; Blumenstock, Gunnar; Bartz-Schmidt, Karl-Ulrich; Besch, Dorothea; Schramm, Charlotte

    2013-12-01

    Amblyopia is one of the most common visual disorders in children. The risk of severe visual impairment on the healthy eye is doubled in patients with amblyopia. If detected early enough, the chances of visual rehabilitation are good. Treatment consists of refractive correction and occlusion of the dominant eye. Patient compliance is an important factor and can be monitored using thermosensors. It was the goal of our study to give proof of the principle that the wearing times of glasses and patches can be measured using a comparatively small and commercially available microsensor. Agreement between wearing times protocols of ocular patching/refractive correction and temperature measurements of thermosensors attached to the patches or glasses of three individuals were analysed using the Bland-Altman method. It was also analysed whether blinded persons could distinguish between temperature curves of patches and glasses, or temperature curves of an incubator or while worn in a pocket. The temperatures picked up by the microsensors indicate the beginning and the end wearing times of either glasses or ocular patches through steep temperature difference and a distinct temperature curve during measurements. Although blinded test persons were able to cleary distinguish between temperature profiles from incubator/pocket measurements compared to glasses/patching, glasses and patching curves could be discriminated correctly in only 50%. Differences between wearing time protocols and temperature measurements were within the limits of agreement as stated by the Bland-Altman plots. The TheraMon(®) microsensor can reliably measure wearing times of glasses and ocular patches without making the wearer uncomfortable, although the data are not unquestionable, especially in higher surrounding temperatures. Further studies on a larger number of individuals with different wearing profiles are needed. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons

  7. Toward a New Gold Standard for Early Safety: Automated Temperature-Controlled hERG Test on the PatchLiner®

    PubMed Central

    Polonchuk, Liudmila

    2012-01-01

    The Patchliner® temperature-controlled automated patch clamp system was evaluated for testing drug effects on potassium currents through human ether-à-go-go related gene (hERG) channels expressed in Chinese hamster ovary cells at 35–37°C. IC50 values for a set of reference drugs were compared with those obtained using the conventional voltage clamp technique. The results showed good correlation between the data obtained using automated and conventional electrophysiology. Based on these results, the Patchliner® represents an innovative automated electrophysiology platform for conducting the hERG assay that substantially increases throughput and has the advantage of operating at physiological temperature. It allows fast, accurate, and direct assessment of channel function to identify potential proarrhythmic side effects and sets a new standard in ion channel research for drug safety testing. PMID:22303293

  8. Medical College of Georgia Complex figures in repeated memory testing: a preliminary study of healthy young adults.

    PubMed

    Yasugi, Mina; Yamashita, Hikari

    2010-02-01

    The Medical College of Georgia Complex Figures developed as an alternate version of the Rey-Osterrieth Complex Figure for repeated assessments. The aim of this study was to examine whether serial assessment with different figures of the Medical College of Georgia Complex Figures could attenuate the practice effects. 64 volunteers (M age = 20.0 yr., SD = 1.9) from a Japanese university were randomly assigned to Same or Different figure conditions. Participants in the Same figure condition underwent repeated assessment using Figure 1 of the Medical College of Georgia Complex Figures on both trials, whereas participants in the Different figure condition received Figure 1 on first trials and the Figure 2 on second trials over a 1-mo. test-retest interval. While the Same figure condition showed significant improvements at recall, no practice effect was observed in the Different figure condition. The findings indicated that use of different figures may help attenuate practice effects in repeated testing.

  9. Repeatable electrical measurement instrumentation for use in the accelerated stress testing of thin film solar cells

    NASA Technical Reports Server (NTRS)

    Davis, C. W.; Lathrop, J. W.

    1985-01-01

    Attention is given to the construction, calibration, and performance of a repeatable measurement system for use in conjunction with the accelerated stress testing of a-Si:H cells. A filtered diode array is utilized to approximate the spectral response of any type of solar cell in discrete portions of the spectrum. It is noted that in order to achieve the necessary degree of overall repeatability, it is necessary to pay particular attention to methods of contacting and positioning the cells.

  10. Effects of Spatial Patch Arrangement and Scale of Covarying Resources on Growth and Intraspecific Competition of a Clonal Plant

    PubMed Central

    Wang, Yong-Jian; Shi, Xue-Ping; Meng, Xue-Feng; Wu, Xiao-Jing; Luo, Fang-Li; Yu, Fei-Hai

    2016-01-01

    Spatial heterogeneity in two co-variable resources such as light and water availability is common and can affect the growth of clonal plants. Several studies have tested effects of spatial heterogeneity in the supply of a single resource on competitive interactions of plants, but none has examined those of heterogeneous distribution of two co-variable resources. In a greenhouse experiment, we grew one (without intraspecific competition) or nine isolated ramets (with competition) of a rhizomatous herb Iris japonica under a homogeneous environment and four heterogeneous environments differing in patch arrangement (reciprocal and parallel patchiness of light and soil water) and patch scale (large and small patches of light and water). Intraspecific competition significantly decreased the growth of I. japonica, but at the whole container level there were no significant interaction effects of competition by spatial heterogeneity or significant effect of heterogeneity on competitive intensity. Irrespective of competition, the growth of I. japonica in the high and the low water patches did not differ significantly in the homogeneous treatments, but it was significantly larger in the high than in the low water patches in the heterogeneous treatments with large patches. For the heterogeneous treatments with small patches, the growth of I. japonica was significantly larger in the high than in the low water patches in the presence of competition, but such an effect was not significant in the absence of competition. Furthermore, patch arrangement and patch scale significantly affected competitive intensity at the patch level. Therefore, spatial heterogeneity in light and water supply can alter intraspecific competition at the patch level and such effects depend on patch arrangement and patch scale. PMID:27375630

  11. Effects of Spatial Patch Arrangement and Scale of Covarying Resources on Growth and Intraspecific Competition of a Clonal Plant.

    PubMed

    Wang, Yong-Jian; Shi, Xue-Ping; Meng, Xue-Feng; Wu, Xiao-Jing; Luo, Fang-Li; Yu, Fei-Hai

    2016-01-01

    Spatial heterogeneity in two co-variable resources such as light and water availability is common and can affect the growth of clonal plants. Several studies have tested effects of spatial heterogeneity in the supply of a single resource on competitive interactions of plants, but none has examined those of heterogeneous distribution of two co-variable resources. In a greenhouse experiment, we grew one (without intraspecific competition) or nine isolated ramets (with competition) of a rhizomatous herb Iris japonica under a homogeneous environment and four heterogeneous environments differing in patch arrangement (reciprocal and parallel patchiness of light and soil water) and patch scale (large and small patches of light and water). Intraspecific competition significantly decreased the growth of I. japonica, but at the whole container level there were no significant interaction effects of competition by spatial heterogeneity or significant effect of heterogeneity on competitive intensity. Irrespective of competition, the growth of I. japonica in the high and the low water patches did not differ significantly in the homogeneous treatments, but it was significantly larger in the high than in the low water patches in the heterogeneous treatments with large patches. For the heterogeneous treatments with small patches, the growth of I. japonica was significantly larger in the high than in the low water patches in the presence of competition, but such an effect was not significant in the absence of competition. Furthermore, patch arrangement and patch scale significantly affected competitive intensity at the patch level. Therefore, spatial heterogeneity in light and water supply can alter intraspecific competition at the patch level and such effects depend on patch arrangement and patch scale.

  12. Safety assessment of a novel active ingredient, acetyl aspartic acid, according to the EU Cosmetics Regulation and the Scientific Committee on Consumer Safety guidelines.

    PubMed

    Daly, P; Moran, G

    2015-10-01

    Acetyl aspartic acid (A-A-A) was proposed as a new novel active ingredient for use in cosmetics. The safety of A-A-A was assessed by following an in-house-developed 'New Ingredient Testing Strategy', which was designed in accordance with the Scientific Committee on Consumer Safety (SCCS) notes of guidance and the requirements of Annex I of the EU Cosmetics Regulation. The aim of the project was to determine whether A-A-A was safe for use in cosmetics and to determine a maximum permitted safe level in the formulations. A literature review was conducted, consulting over 40 different information sources. This highlighted a number of gaps which required testing data. A-A-A was tested for phototoxicity according to OECD test guideline 432, skin irritation according to OECD test guideline 439 and eye irritation according to OECD test guideline 437. Dermal absorption of A-A-A was measured according to OECD test guideline 428 and was used to calculate the margin of safety (MoS). Finally, A-A-A was tested in a human repeat insult patch test (HRIPT) and a 14-day in-use tolerance study. A-A-A was non-phototoxic and was non-irritating to skin and eyes in in vitro testing. Dermal absorption was calculated to be 5%. The MoS for A-A-A was 351, at a level of 5%, for all cosmetic product types, indicating no systemic safety toxicity concern. A-A-A at 5% under occlusive patch on a panel of 50 adult volunteers induced no skin irritation or allergic reaction in the HRIPT study. Finally, repeated application of A-A-A to the periocular area, twice per day for 14 days, in 21 female volunteers, demonstrated that 1% A-A-A was well tolerated following dermatological and ophthalmological assessment in a cosmetic formulation. A-A-A was assessed as safe by the cosmetic safety assessor for use in cosmetics at a level of 5% in all cosmetic product types, in line with the requirements of the EU Cosmetics Regulation and in accordance with the SCCS notes of guidance. © 2015 Society of Cosmetic

  13. Nanowired three-dimensional cardiac patches

    NASA Astrophysics Data System (ADS)

    Dvir, Tal; Timko, Brian P.; Brigham, Mark D.; Naik, Shreesh R.; Karajanagi, Sandeep S.; Levy, Oren; Jin, Hongwei; Parker, Kevin K.; Langer, Robert; Kohane, Daniel S.

    2011-11-01

    Engineered cardiac patches for treating damaged heart tissues after a heart attack are normally produced by seeding heart cells within three-dimensional porous biomaterial scaffolds. These biomaterials, which are usually made of either biological polymers such as alginate or synthetic polymers such as poly(lactic acid) (PLA), help cells organize into functioning tissues, but poor conductivity of these materials limits the ability of the patch to contract strongly as a unit. Here, we show that incorporating gold nanowires within alginate scaffolds can bridge the electrically resistant pore walls of alginate and improve electrical communication between adjacent cardiac cells. Tissues grown on these composite matrices were thicker and better aligned than those grown on pristine alginate and when electrically stimulated, the cells in these tissues contracted synchronously. Furthermore, higher levels of the proteins involved in muscle contraction and electrical coupling are detected in the composite matrices. It is expected that the integration of conducting nanowires within three-dimensional scaffolds may improve the therapeutic value of current cardiac patches.

  14. Correlation of open cell-attached and excised patch clamp techniques.

    PubMed

    Filipovic, D; Hayslett, J P

    1995-11-01

    The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.

  15. Patch Time Allocation and Oviposition Behavior in Response to Patch Quality and the Presence of a Generalist Predator in Meteorus pulchricornis (Hymenoptera: Braconidae)

    PubMed Central

    Sheng, Sheng; Ling, Meng; Fu-an, Wu; Baoping, Li

    2015-01-01

    Foraging parasitoids often must estimate local risk of predation just as they must estimate local patch value. Here, we investigate the effects a generalist predator Chlaenius bioculatus (Coleoptera: Carabidae), has on the oviposition behavior and the patch residence decisions of a solitary parasitoid Meteorus pulchricornis (Hymenoptera: Braconidae) in response to the varying host quality of Spodoptera litura (Lepidoptera: Noctuidae) larvae (L2 and L4). M. pulchricornis attacked more L4 than on L2 hosts, with the difference in attack rate varying depending on predation treatments, greater in the presence (either actively feeding or not) of the predator than in the absence of it. The parasitoid attacked fewer L2 and L4 hosts when the predator was actively feeding than when it was not feeding or not present in the patch. M. pulchricornis decreased the patch leaving tendency with increasing rejections of hosts, but increased the tendency in response to the presence of the predator as compared with the absence of it, and furthermore, increased the patch leaving tendency when the predator was actively feeding as compared with when it was not. Our study suggests that M. pulchricornis can exploit high quality patches while minimizing predation risk, by attacking more hosts in high quality patches while reducing total patch time in response to risk of predation. PMID:25943317

  16. Ex-vivoand in-vitro assessment of mucoadhesive patches containing the gel-forming polysaccharide psyllium for buccal delivery of chlorhexidine base.

    PubMed

    Cavallari, Cristina; Brigidi, Patrizia; Fini, Adamo

    2015-12-30

    The aim of the present study was to evaluate the gel-forming polysaccharide psyllium in the preparation of mucoadhesive patches for the controlled release of chlorhexidine (CHX) to treat pathologies in the oral cavity, using the casting-solvent evaporation technique. A number of different film-forming semi-synthetic polymers, such as sodium carboxymethyl cellulose (SCMC) and hydroxypropylmethyl cellulose (HPMC) were evaluated for comparison. The patch formulations were characterized in terms of drug content, morphology surface, swelling and mucoadhesive properties, microbiology inhibition assay and in vitro release tests. Three ex-vivo testswere carried out using porcine mucosa: an alternative dissolution test using artificial saliva that allows contemporary measurement of dissolution and mucoadhesion, a permeation test through the mucosa and the measurement of mucoadhesion using a Nouy tensile tester, as the maximum force required for the separation of the patch from the mucosa surface. The patches were also examined for determination of the minimum inhibitory concentration in cultures of Escherichia coli and Staphylococcus aureus. All the patches incorporating psyllium were found suitable in terms of external morphology, mucoadhesion and controlled release of the drug: in the presence of psyllium the drug displays prolonged zero-order release related to slower swelling rate of the system. Copyright © 2015. Published by Elsevier B.V.

  17. Knowledge-based design of generate-and-patch problem solvers that solve global resource assignment problems

    NASA Technical Reports Server (NTRS)

    Voigt, Kerstin

    1992-01-01

    We present MENDER, a knowledge based system that implements software design techniques that are specialized to automatically compile generate-and-patch problem solvers that satisfy global resource assignments problems. We provide empirical evidence of the superior performance of generate-and-patch over generate-and-test: even with constrained generation, for a global constraint in the domain of '2D-floorplanning'. For a second constraint in '2D-floorplanning' we show that even when it is possible to incorporate the constraint into a constrained generator, a generate-and-patch problem solver may satisfy the constraint more rapidly. We also briefly summarize how an extended version of our system applies to a constraint in the domain of 'multiprocessor scheduling'.

  18. Computer-aided patch planning for treatment of complex coarctation of the aorta

    NASA Astrophysics Data System (ADS)

    Rietdorf, Urte; Riesenkampff, Eugénie; Kuehne, Titus; Huebler, Michael; Meinzer, Hans-Peter; Wolf, Ivo

    2009-02-01

    Between five and eight percent of all children born with congenitally malformed hearts suffer from coarctations of the aorta. Some severe coarctations can only be treated by surgical repair. Untreated, this defect can cause serious damage to organ development or even lead to death. Patch repair requires open surgery. It can affect patients of any age: newborns with severe coarctation and/or hypoplastic aortic arch as well as older patients with late diagnosis of coarctation of the aorta. Another patient group are patients of varying age with re-coarctation of the aorta or hypoplastic aortic arch after surgical and/or interventional repair. If anatomy is complex and interventional treatment by catheterization, balloon angioplasty or stent placement is not possible, surgery is indicated. The choice of type of surgery depends not only on the given anatomy but also on the experience the surgical team has with each method. One surgical approach is patch repair. A patch of a suitable shape and size is sewed into the aorta to expand the aortic lumen at the site of coarctation. At present, the shape and size of the patch are estimated intra-operatively by the surgeon. We have developed a software application that allows planning of the patch pre-operatively on the basis of magnetic resonance angiographic data. The application determines the diameter of the coarctation and/or hypoplastic segment and constructs a patch proposal by calculating the difference to the normal vessel diameter pre-operatively. Evaluation of MR angiographic datasets from 12 test patients with different kinds of aortic arch stenosis shows a divergence of only (1.5+/-1.2) mm in coarctation diameters between manual segmentations and our approach, with comparable time expenditure. Following this proposal the patch can be prepared and adapted to the patient's anatomy pre-operatively. Ideally, this leads to shorter operation times and a better long-term outcome with a reduced rate of residual stenosis and

  19. Behavioral response races, predator-prey shell games, ecology of fear, and patch use of pumas and their ungulate prey.

    PubMed

    Laundré, John W

    2010-10-01

    The predator-prey shell game predicts random movement of prey across the landscape, whereas the behavioral response race and landscape of fear models predict that there should be a negative relationship between the spatial distribution of a predator and its behaviorally active prey. Additionally, prey have imperfect information on the whereabouts of their predator, which the predator should incorporate in its patch use strategy. I used a one-predator-one-prey system, puma (Puma concolor)-mule deer (Odocoileus hemionus) to test the following predictions regarding predator-prey distribution and patch use by the predator. (1) Pumas will spend more time in high prey risk/low prey use habitat types, while deer will spend their time in low-risk habitats. Pumas should (2) select large forage patches more often, (3) remain in large patches longer, and (4) revisit individual large patches more often than individual smaller ones. I tested these predictions with an extensive telemetry data set collected over 16 years in a study area of patchy forested habitat. When active, pumas spent significantly less time in open areas of low intrinsic predation risk than did deer. Pumas used large patches more than expected, revisited individual large patches significantly more often than smaller ones, and stayed significantly longer in larger patches than in smaller ones. The results supported the prediction of a negative relationship in the spatial distribution of a predator and its prey and indicated that the predator is incorporating the prey's imperfect information about its presence. These results indicate a behavioral complexity on the landscape scale that can have far-reaching impacts on predator-prey interactions.

  20. Sensitization to Rubber Accelerators in Northeastern Italy: The Triveneto Patch Test Database.

    PubMed

    Buttazzo, Silvia; Prodi, Andrea; Fortina, Anna Belloni; Corradin, Maria Teresa; Larese Filon, Francesca

    2016-01-01

    Natural and synthetic rubbers containing rubber accelerators are well-known causes of occupational skin disease. Allergic contact dermatitis caused by rubber gloves is frequent and has almost exclusively been attributed to contact sensitization to accelerators. This study aimed to evaluate the frequency of rubber accelerators sensitization in the population living in northeastern Italy, to find time trend and a correlation with occupations, and to investigate co-sensitization between rubber accelerators. A population of 23,774 subjects was patch tested in 6 cities in northeastern Italy in the years 1996 to 2012 using carba mix 3%, thiuram mix 1%, benzothiazole (MBT) mix 1%, and isopropyl phenyl paraphenylamine diamine (IPPD) mix 0.6%. The overall frequency of carbamates, MBT, thiurams, and IPPD mix sensitization was 3.4%, 0.65%, 1.75%, and 0.83%, respectively. On a logistic regression analysis (control group: white-collar workers), we found a statistically significant association to carbamates (odds ratio [OR], 1.3; 95% confidence interval [CI], 1.03-1.7) and thiurams (OR, 1.6; 95% CI, 1.1-2.3) for health care workers. Thiuram sensitivity was also significantly associated with dermatitis in maids and restaurant workers (OR, 2.2; 95% CI, 1.4-3.6), hairdressers (OR, 3.6; 95% CI, 1.8-7.1), shop assistants (OR, 2.9; 95% CI, 1.2-6.8), construction workers (OR, 2.7; 95% CI, 1.7-4.1), mechanics (OR, 2.1; 95% CI, 1.3-3.4), and professional drivers (OR, 2.6; 95% CI, 1.2-5.9). In conclusion, our results demonstrated that rubber accelerators have an important role in allergic contact dermatitis in the northeast of Italy and their sensitization is associated significantly with occupations that wear gloves or use chemical substances. Between rubber accelerators tested, carbamates sensitization is prevalent and increasing during considered years.