Saadulla, Lawand; Reeves, W Brian; Irey, Brittany; Ghahramani, Nasrollah
2012-02-01
To investigate the impacts of availability of pre-mixed solutions and computerized order entry on nephrologists' choice of the initial mode of renal replacement therapy in acute renal failure. We studied 898 patients with acute renal failure in 3 consecutive eras: era 1 (custom-mixed solution; n = 309), era 2 (pre-mixed commercial solution; n = 324), and era 3 (post-computerized order entry; n = 265). The proportion of patients treated with renal replacement therapy and the time from consult to initiation of continuous renal replacement therapy was similar in the 3 eras. Following introduction of the pre-mixed solution, the proportion of patients treated with continuous renal replacement therapy increased (20% vs. 33%; p < 0.05), it was initiated at a lower serum creatinine (353 ± 123 μmol/L vs. 300 ± 80 μmol/L; p < 0.05) and in older patients (53 ± 12 vs. 61 ± 14 years; p < 0.05). There was a progressive increase in the use of continuous veno-venous hemodialysis (18% vs. 79% vs. 100%; p < 0.05) and in the total prescribed flow rate (1,382 ± 546 vs. 2,324 ± 737 vs. 2,900 ± 305 mL/hr 3; p < 0.05). There was no significant impact on mortality. The availability of a pre-mixed solution increases the likelihood of initiating continuous renal replacement therapy in acute renal failure, initiating it at a lower creatinine and for older patients, use of continuous veno-venous hemodialysis and higher prescribed continuous renal replacement therapy dose. Computerized order entry implementation is associated with an additional increase in the use of continuous veno-venous hemodialysis, higher total prescribed dialysis dose, and use of CRRT among an increasing number of patients not on mechanical ventilation. The effect of these changes on patient survival is not significant.
Redaelli, Sara; Zanella, Alberto; Milan, Manuela; Isgrò, Stefano; Lucchini, Alberto; Pesenti, Antonio; Patroniti, Nicolò
2016-12-01
Daily nursing in critical care patients may alter vital parameters, especially in the most critically ill patients. The aim of our study was to evaluate feasibility and safety of daily nursing on patients undergoing venous-venous extracorporeal membrane oxygenation (vv-ECMO) for severe respiratory failure. Daily nursing was performed following defined phases (sponge bath, elevation with scooping stretcher, change position of endotracheal tube, dressing replacement). We recorded physiological and ECMO parameters before and during daily nursing in 5 patients for several days (total: 25 daily nursing) and adverse events: desaturation, hypertension, reduction of mixed venous oxygen saturation, arterial oxygen saturation or ECMO blood flow and elevation in minute ventilation. Sedative drug dosage and additional bolus were recorded. Daily nursing was performed in 92 % of cases (23/25), with a minimum of two adverse events per daily nursing. Hypertension and tachycardia were mostly recorded at the beginning, while desaturation, reduction in mixed venous oxygen saturation and blood flow were recorded during elevation with scooping stretcher. Increase in minute ventilation was frequent in spontaneous breathing patients. Additional bolus of sedation was required before and/or during nursing. Daily nursing significantly alters physiologic parameters; thus, it should be performed only when physicians are readily available to treat adverse events.
Association of physical examination with pulmonary artery catheter parameters in acute lung injury.
Grissom, Colin K; Morris, Alan H; Lanken, Paul N; Ancukiewicz, Marek; Orme, James F; Schoenfeld, David A; Thompson, B Taylor
2009-10-01
To correlate physical examination findings, central venous pressure, fluid output, and central venous oxygen saturation with pulmonary artery catheter parameters. Retrospective study. Data from the multicenter Fluid and Catheter Treatment Trial of the National Institutes of Health Acute Respiratory Distress Syndrome Network. Five hundred thirteen patients with acute lung injury randomized to treatment with a pulmonary artery catheter. Correlation of physical examination findings (capillary refill time >2 secs, knee mottling, or cool extremities), central venous pressure, fluid output, and central venous oxygen saturation with parameters from a pulmonary artery catheter. We determined association of baseline physical examination findings and on-study parameters of central venous pressure and central venous oxygen saturation with cardiac index <2.5 L/min/m2 and mixed venous oxygen saturation <60%. We determined correlation of baseline central venous oxygen saturation and mixed venous oxygen saturation and predictive value of a low central venous oxygen saturation for a low mixed venous oxygen saturation. Prevalence of cardiac index <2.5 and mixed venous oxygen saturation <60% was 8.1% and 15.5%, respectively. Baseline presence of all three physical examination findings had low sensitivity (12% and 8%), high specificity (98% and 99%), low positive predictive value (40% and 56%), but high negative predictive value (93% and 86%) for cardiac index <2.5 and mixed venous oxygen saturation <60%, respectively. Central venous oxygen saturation <70% predicted a mixed venous oxygen saturation <60% with a sensitivity 84%,specificity 70%, positive predictive value 31%, and negative predictive value of 96%. Low cardiac index correlated with cool extremities, high central venous pressure, and low 24-hr fluid output; and low mixed venous oxygen saturation correlated with knee mottling and high central venous pressure, but these correlations were not found to be clinically useful. In this subset of patients with acute lung injury, there is a high prior probability that cardiac index and mixed venous oxygen saturation are normal and physical examination findings of ineffective circulation are not useful for predicting low cardiac index or mixed venous oxygen saturation. Central venous oxygen saturation <70% does not accurately predict mixed venous oxygen saturation <60%, but a central venous oxygen saturation >or=70% may be useful to exclude mixed venous oxygen saturation <60%.
O'Connor, T M; Barry, P J; Jahangir, A; Finn, C; Buckley, B M; El-Gammal, A
2011-01-01
Arterial blood gases (ABGs) are often sampled incorrectly, leading to a 'mixed' or venous sample. Delays in analysis and air contamination are common. We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. Mean venous pH was 7.371 and arterial pH was 7.407 (p < 0.0001). There was a correlation between venous and arterial pH (r = 0.5347, p < 0.0001). The regression equation to predict arterial pH was: arterial pH = 4.2289 + 0.43113 · venous pH. There were no clinically significant differences in arterial PO₂ associated with analysis delay. A statistically significant decline in pH was detected at 30 min in patients with COPD exacerbation (p = 0.0042) and 90 min in controls (p < 0.0001). A clinically significant decline in pH emerged at 73 min in patients with COPD exacerbation and 87 min in controls. Air contamination was associated with a clinically significant increase in PO₂ in all samples, including those that were immediately analyzed. Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO₂, indicating that air-contaminated ABGs should be discarded. Copyright © 2010 S. Karger AG, Basel.
Labeau, Sonia O; Vandijck, Dominique M; Rello, Jordi; Adam, Sheila; Rosa, Ana; Wenisch, Christoph; Bäckman, Carl; Agbaht, Kemal; Csomos, Akos; Seha, Myriam; Dimopoulos, George; Vandewoude, Koenraad H; Blot, Stijn I
2009-01-01
To determine European intensive care unit (ICU) nurses' knowledge of guidelines for preventing central venous catheter-related infection from the Centers for Disease Control and Prevention. Multicountry survey (October 2006-March 2007). Twenty-two European countries. ICU nurses. Using a validated multiple-choice test, knowledge of ten recommendations for central venous catheter-related infection prevention was evaluated (one point per question) and assessed in relation to participants' gender, ICU experience, number of ICU beds, and acquisition of a specialized ICU qualification. We collected 3405 questionnaires (70.9% response rate); mean test score was 44.4%. Fifty-six percent knew that central venous catheters should be replaced on indication only, and 74% knew this also concerns replacement over a guidewire. Replacing pressure transducers and tubing every 4 days, and using coated devices in patients requiring a central venous catheter >5 days in settings with high infection rates only were recognized as recommended by 53% and 31%, respectively. Central venous catheters dressings in general are known to be changed on indication and at least once weekly by 43%, and 26% recognized that both polyurethane and gauze dressings are recommended. Only 14% checked 2% aqueous chlorhexidine as the recommended disinfection solution; 30% knew antibiotic ointments are not recommended because they trigger resistance. Replacing administration sets within 24 hrs after administering lipid emulsions was recognized as recommended by 90%, but only 26% knew sets should be replaced every 96 hrs when administering neither lipid emulsions nor blood products. Professional seniority and number of ICU beds showed to be independently associated with better test scores. Opportunities exist to optimize knowledge of central venous catheter-related infection prevention among European ICU nurses. We recommend including central venous catheter-related infection prevention guidelines in educational curricula and continuing refresher education programs.
Comparison of Minimally and More Invasive Methods of Determining Mixed Venous Oxygen Saturation.
Smit, Marli; Levin, Andrew I; Coetzee, Johan F
2016-04-01
To investigate the accuracy of a minimally invasive, 2-step, lookup method for determining mixed venous oxygen saturation compared with conventional techniques. Single-center, prospective, nonrandomized, pilot study. Tertiary care hospital, university setting. Thirteen elective cardiac and vascular surgery patients. All participants received intra-arterial and pulmonary artery catheters. Minimally invasive oxygen consumption and cardiac output were measured using a metabolic module and lithium-calibrated arterial waveform analysis (LiDCO; LiDCO, London), respectively. For the minimally invasive method, Step 1 involved these minimally invasive measurements, and arterial oxygen content was entered into the Fick equation to calculate mixed venous oxygen content. Step 2 used an oxyhemoglobin curve spreadsheet to look up mixed venous oxygen saturation from the calculated mixed venous oxygen content. The conventional "invasive" technique used pulmonary artery intermittent thermodilution cardiac output, direct sampling of mixed venous and arterial blood, and the "reverse-Fick" method of calculating oxygen consumption. LiDCO overestimated thermodilution cardiac output by 26%. Pulmonary artery catheter-derived oxygen consumption underestimated metabolic module measurements by 27%. Mixed venous oxygen saturation differed between techniques; the calculated values underestimated the direct measurements by between 12% to 26.3%, this difference being statistically significant. The magnitude of the differences between the minimally invasive and invasive techniques was too great for the former to act as a surrogate of the latter and could adversely affect clinical decision making. Copyright © 2016 Elsevier Inc. All rights reserved.
Nitzan, Meir; Nitzan, Itamar
2013-08-01
The oxygen saturation of the systemic arterial blood is associated with the adequacy of respiration, and can be measured non-invasively by pulse oximetry in the systemic tissue. The oxygen saturation of the blood in the pulmonary artery, the mixed venous blood, reflects the balance between oxygen supply to the systemic tissues and their oxygen demand. The mixed venous oxygen saturation has also clinical significance because it is used in Fick equation for the quantitative measurement of cardiac output. At present the measurement of the mixed venous oxygen saturation is invasive and requires insertion of a Swan-Ganz catheter into the pulmonary artery. We suggest a noninvasive method for the measurement of the mixed venous oxygen saturation in infants, pulmonary pulse oximetry. The method is similar to the systemic pulse oximetry, which is based on the different light absorption curves of oxygenated and deoxygenated hemoglobin and on the analysis of photoplethysmographic curves in two wavelengths. The proposed pulmonary pulse oximeter includes light-sources of two wavelengths in the infrared, which illuminate the pulmonary tissue through the thoracic wall. Part of the light which is scattered back from the pulmonary tissue and passes through the thoracic wall is detected, and for each wavelength a pulmonary photoplethysmographic curve is obtained. The pulmonary photoplethysmographic curves reflect blood volume increase during systole in the pulmonary arteries in the lung tissue, which contain mixed venous blood. The ratio R of the amplitude-to-baseline ratio for the two wavelengths is related to the mixed venous oxygen saturation through equations derived for the systemic pulse oximetry. The method requires the use of extinction coefficients values for oxygenated and deoxygenated hemoglobin, which can be found in the literature. Copyright © 2013 Elsevier Ltd. All rights reserved.
A new approach to non-invasive oxygenated mixed venous PCO(sub)2
NASA Technical Reports Server (NTRS)
Fisher, Joseph A.; Ansel, Clifford A.
1986-01-01
A clinically practical technique was developed to calculate mixed venous CO2 partial pressure for the calculation of cardiac output by the Fick technique. The Fick principle states that the cardiac output is equal to the CO2 production divided by the arterio-venous CO2 content difference of the pulmonary vessels. A review of the principles involved in the various techniques used to estimate venous CO2 partial pressure is presented.
Aguilar-Ferrándiz, M Encarnación; Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Guisado-Barrilao, Rafael; García-Ríos, M Carmen; Moreno-Lorenzo, Carmen
2014-01-01
To investigate the effect of a mixed Kinesio taping treatment in women with chronic venous insufficiency. A double-blinded randomized clinical trial. Clinical setting. One hundred and twenty postmenopausal women with mild-moderate chronic venous insufficiency were randomly assigned to an experimental group receiving standardized Kinesio taping treatment for gastrocnemius muscle enhancement and ankle functional correction, or to a placebo control group for simulated Kinesio taping. MAIN OUTCOMES VARIABLES: Venous symptoms, pain, photoplethysmographic measurements, bioelectrical impedance, temperature, severity and overall health were recorded at baseline and after four weeks of treatment. The 2 × 2 mixed model ANCOVA with repeated measurements showed statistically significant group * time interaction for heaviness (F = 22.99, p = 0.002), claudication (F = 8.57, p = 0.004), swelling (F = 22.58, p = 0.001), muscle cramps (F = 7.14, p = 0.008), venous refill time (right: F = 9.45, p = 0.023; left: F = 14.86, p = 0.001), venous pump function (right: F = 35.55, p = 0.004; left: F = 17.39 p = 0.001), extracellular water (right: F = 35.55, p = 0.004; left: F = 23.84, p = 0.001), severity (F = 18.47, p = 0.001), physical function (F = 9.15, p = 0.003) and body pain (F = 3.36, p = 0.043). Both groups reported significant reduction in pain. Mixed Kinesio taping-compression therapy improves symptoms, peripheral venous flow and severity and slightly increases overall health status in females with mild chronic venous insufficiency. Kinesio taping may have a placebo effect on pain.
Krivec, Bojan; Voga, Gorazd; Podbregar, Matej
2004-05-31
Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.
Doshi, Ankur M; Hoffman, David; Kierans, Andrea S; Ream, Justin M; Rosenkrantz, Andrew B
2015-10-01
The objective of this study is to assess the performance of qualitative and quantitative imaging features for the differentiation of deep venous thrombosis (DVT) from mixing artifact on routine portal venous phase abdominopelvic CT. This retrospective study included 40 adult patients with a femoral vein filling defect on portal venous phase CT and a Duplex ultrasound (n = 36) or catheter venogram (n = 4) to confirm presence or absence of DVT. Two radiologists (R1, R2) assessed the femoral veins for various qualitative and quantitative features. 60% of patients were confirmed to have DVT and 40% had mixing artifact. Features with significantly greater frequency in DVT than mixing artifact (all p ≤ 0.006) were central location (R1 90% vs. 28%; R2 96% vs. 31%), sharp margin (R1 83% vs. 28%; R2 96% vs. 31%), venous expansion (R1 48% vs. 6%, R2 56% vs. 6%), and venous wall enhancement (R1 62% vs. 0%; R2 48% vs. 0%). DVT exhibited significantly lower mean attenuation than mixing artifact (R1 42.1 ± 20.2 vs. 57.1 ± 23.6 HU; R2 43.6 ± 19.4 vs. 58.8 ± 23.4 HU, p ≤ 0.031) and a significantly larger difference in vein diameter compared to the contralateral vein (R1 0.4 ± 0.4 vs. 0.1 ± 0.2 cm; R2 0.3 ± 0.4 vs. 0.0 ± 0.1 cm, p ≤ 0.026). At multivariable analysis, central location and sharp margin were significant independent predictors of DVT for both readers (p ≤ 0.013). Awareness of these qualitative and quantitative imaging features may improve radiologists' confidence for differentiating femoral vein DVT and mixing artifact on routine portal venous phase CT. However, given overlap with mixing artifact, larger studies remain warranted.
Henthorn, Thomas K; Avram, Michael J; Dahan, Albert; Gustafsson, Lars L; Persson, Jan; Krejcie, Tom C; Olofsen, Erik
2018-05-16
The pharmacokinetics of infused drugs have been modeled without regard for recirculatory or mixing kinetics. We used a unique ketamine dataset with simultaneous arterial and venous blood sampling, during and after separate S(+) and R(-) ketamine infusions, to develop a simplified recirculatory model of arterial and venous plasma drug concentrations. S(+) or R(-) ketamine was infused over 30 min on two occasions to 10 healthy male volunteers. Frequent, simultaneous arterial and forearm venous blood samples were obtained for up to 11 h. A multicompartmental pharmacokinetic model with front-end arterial mixing and venous blood components was developed using nonlinear mixed effects analyses. A three-compartment base pharmacokinetic model with additional arterial mixing and arm venous compartments and with shared S(+)/R(-) distribution kinetics proved superior to standard compartmental modeling approaches. Total pharmacokinetic flow was estimated to be 7.59 ± 0.36 l/min (mean ± standard error of the estimate), and S(+) and R(-) elimination clearances were 1.23 ± 0.04 and 1.06 ± 0.03 l/min, respectively. The arm-tissue link rate constant was 0.18 ± 0.01 min and the fraction of arm blood flow estimated to exchange with arm tissue was 0.04 ± 0.01. Arterial drug concentrations measured during drug infusion have two kinetically distinct components: partially or lung-mixed drug and fully mixed-recirculated drug. Front-end kinetics suggest the partially mixed concentration is proportional to the ratio of infusion rate and total pharmacokinetic flow. This simplified modeling approach could lead to more generalizable models for target-controlled infusions and improved methods for analyzing pharmacokinetic-pharmacodynamic data.
Modified repair of mixed anomalous pulmonary venous connection.
van Son, J A; Hambsch, J; Mohr, F W
1998-05-01
A modified repair technique is reported for mixed total or partial anomalous pulmonary venous connection with the right superior pulmonary vein connecting to the superior vena cava, the right inferior pulmonary vein to the right atrium or left atrium, and the left pulmonary veins to the coronary sinus. The superior vena cava is transected above the highest right superior pulmonary vein, its cephalad end is anastomosed to the right atrial appendage, and a pericardial baffle is constructed between the cardiac ostium of the superior vena cava, the ostium of the right inferior pulmonary vein, and the left atrium, including the coronary sinus, which is unroofed. The reported technique may be valuable to avoid pulmonary venous obstruction in complex mixed forms of total or partial anomalous pulmonary venous connection.
To mix or not to mix venous blood samples collected in vacuum tubes?
Parenmark, Anna; Landberg, Eva
2011-09-08
There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.
Pan, Yu-Ning; Tang, Yi-Fan; Zhang, Jie; Wang, Guo-Yao; Huang, Qiu-Li
2017-01-01
The present study aims to investigate and compare the diagnostic and prognostic value of cavernosography with 320-row dynamic volume computed tomography (DVCT) versus conventional cavernosography in men with erectile dysfunction (ED) caused by venous leakage. A total of 174 patients diagnosed with ED were enrolled and received cavernosography with 320-row DVCT (DVCT group) and conventional cavernosography scans (control group) respectively. The diagnosis, complications, and prognosis of patients were evaluated. The DVCT group provided high-resolution images with less processing and testing time, as well as lowered radiological agent and contrast agent compared with the control group. In the DVCT group, 89 patients who were diagnosed with venous ED had six various venous leakage, namely superficial venous leakage, profundus venous leakage, the mixed type, cavernosal venous leakage, crural venous leakage, and also venous leakage between the penis and urethra cavernosum (9, 21, 32, 6, 18, and 3 cases respectively). Similarly, 74 patients out of the 81 who suffered from venous ED were classified to have superficial venous leakage (11), profundus venous leakage (14), the mixed type venous leakage (26), and middle venous leakage (23). Six out of 25 patients in the DVCT group, had improvements in ED while the remaining 19 achieved full erectile function recovery with no penile fibrosis and erectile pain. Cavernosography with 320-row DVCT is a reliable system that can be used to diagnose ED caused by venous leakage. This is especially useful in accurately determining the type of venous and allows for a better prognosis and direction of treatment. PMID:28424371
Mixed-venous oxygen tension by nitrogen rebreathing - A critical, theoretical analysis.
NASA Technical Reports Server (NTRS)
Kelman, G. R.
1972-01-01
There is dispute about the validity of the nitrogen rebreathing technique for determination of mixed-venous oxygen tension. This theoretical analysis examines the circumstances under which the technique is likely to be applicable. When the plateau method is used the probable error in mixed-venous oxygen tension is plus or minus 2.5 mm Hg at rest, and of the order of plus or minus 1 mm Hg during exercise. Provided, that the rebreathing bag size is reasonably chosen, Denison's (1967) extrapolation technique gives results at least as accurate as those obtained by the plateau method. At rest, however, extrapolation should be to 30 rather than to 20 sec.
The Toxicity of Inhaled Sulphur Mustard
2012-03-01
Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and venous ) pH pO2 pCO2 Sodium Potassium Calcium...Cardiovascular Parameters − CFI – Cardiac Function Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure...Data are expressed as mean ± SEM. Changes in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are
Exposed Subcutaneous Implantable Devices: An Operative Protocol for Management and Salvage
D’Arpa, Salvatore; Cordova, Adriana; Moschella, Francesco
2015-01-01
Background: Implantable venous and electrical devices are prone to exposure and infection. Indications for management are controversial, but—especially if infected—exposed devices are often removed and an additional operation is needed to replace the device, causing a delay in chemotherapy and prolonging healing time. We present our protocol for device salvage, on which limited literature is available. Methods: Between 2007 and 2013, 17 patients were treated (12 venous access ports, 3 cardiac pacemakers, and 2 subcutaneous neural stimulators). Most patients were operated within 7 days from exposure. All patients received only a single perioperative dose of prophylactic antibiotic. In cases of gross infection (n = 1), the device was immediately replaced. In the absence of clinical signs of infection: Complete capsulectomy and aggressive cleaning with an n-acetylcysteine solution and saline solution. Primary exposure of venous ports with sufficient skin coverage (n = 10): the device was covered with local skin flaps. Recurrent cases, cases with insufficient skin coverage or big devices (n = 7): the device was moved to a subpectoral pocket. Mean follow-up was 19 months. Results: Sixteen devices were saved. Only one grossly infected pacemaker was removed and replaced immediately. Only in 1 case, exposure of a venous port recurred after 18 months and was successfully moved to a subpectoral pocket. Chemotherapy was always restarted as scheduled and electrical devices remained functional. Conclusions: This protocol allows—with a straightforward operation and simple measures—to save exposed devices even several days after exposure. Submuscular placement or immediate replacement is indicated only in selected cases. PMID:26034650
Impact of Tranexamic Acid in Total Knee and Total Hip Replacement.
Boyle, Jaclyn A; Soric, Mate M
2017-02-01
To evaluate the net clinical benefit of tranexamic acid use in patients undergoing total knee or total hip replacement. This is a retrospective study of patients undergoing total knee or total hip replacement. The primary outcome was the net clinical benefit of tranexamic acid use. Secondary outcomes included length of stay, incidence of venous thromboembolism, change in hemoglobin, and number of units of blood transfused. Four hundred and six patients were screened for inclusion and 327 patients met inclusion criteria; 174 patients received tranexamic acid versus 153 patients who received usual care. Tranexamic acid demonstrated a positive net clinical benefit versus usual care (40.8% vs 13.7%, P < .01) but did not affect length of stay (3.39 vs 3.37 days, respectively, P = .76). Venous thromboembolism was comparable between groups (2.3% vs 0.7%, P = .38). Average change in hemoglobin and need for transfusion were lower in the treatment group versus the usual care group, respectively (3.46 vs 4.26 mg/dL, P < .01). Tranexamic acid demonstrated a significant benefit in decreasing change in hemoglobin as well as the need for blood transfusion with no increase in the risk of venous thromboembolism in patients undergoing total knee or total hip replacement.
Compression therapy in mixed ulcers increases venous output and arterial perfusion.
Mosti, Giovanni; Iabichella, Maria Letizia; Partsch, Hugo
2012-01-01
This study was conducted to define bandage pressures that are safe and effective in treating leg ulcers of mixed arterial-venous etiology. In 25 patients with mixed-etiology leg ulcers who received inelastic bandages applied with pressures from 20 to 30, 31 to 40, and 41 to 50 mm Hg, the following measurements were performed before and after bandage application to ensure patient safety throughout the investigation: laser Doppler fluxmetry (LDF) close to the ulcer under the bandage and at the great toe, transcutaneous oxygen pressure (TcPo(2)) on the dorsum of the foot, and toe pressure. Ejection fraction (EF) of the venous pump was performed to assess efficacy on venous hemodynamics. LDF values under the bandages increased by 33% (95% confidence interval [CI], 17-48; P < .01), 28% (95% CI, 12-45; P < .05), and 10% (95% CI, -7 to 28), respectively, under the three pressure ranges applied. At toe level, a significant decrease in flux of -20% (95% CI, -48 to 9; P < .05) was seen when bandage pressure >41 mm Hg. Toe pressure values and TcPo(2) showed a moderate increase, excluding a restriction to arterial perfusion induced by the bandages. Inelastic bandages were highly efficient in improving venous pumping function, increasing the reduced ejection fraction by 72% (95% CI, 50%-95%; P < .001) under pressure of 21 to 30 mm Hg and by 103% (95% CI, 70%-128%; P < .001) at 31 to 40 mm Hg. In patients with mixed ulceration, an ankle-brachial pressure index >0.5 and an absolute ankle pressure of >60 mm Hg, inelastic compression of up to 40 mm Hg does not impede arterial perfusion but may lead to a normalization of the highly reduced venous pumping function. Such bandages are therefore recommended in combination with walking exercises as the basic conservative management for patients with mixed leg ulcers. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Kumar, Dharmendra; Ahmed, Syed Moied; Ali, Shahna; Ray, Utpal; Varshney, Ankur; Doley, Kashmiri
2015-11-01
Central venous pressure (CVP) assesses the volume status of patients. However, this technique is not without complications. We, therefore, measured peripheral venous pressure (PVP) to see whether it can replace CVP. To evaluate the correlation and agreement between CVP and PVP after passive leg raise (PLR) in critically ill patients on mechanical ventilation. Prospective observational study in Intensive Care Unit. Fifty critically ill patients on mechanical ventilation were included in the study. CVP and PVP measurements were taken using a water column manometer. Measurements were taken in the supine position and subsequently after a PLR of 45°. Pearson's correlation and Bland-Altman's analysis. This study showed a fair correlation between CVP and PVP after a PLR of 45° (correlation coefficient, r = 0.479; P = 0.0004) when the CVP was <10 cmH2O. However, the correlation was good when the CVP was >10 cmH2O. Bland-Altman analysis showed 95% limits of agreement to be -2.912-9.472. PVP can replace CVP for guiding fluid therapy in critically ill patients.
Cicolini, Giancarlo; Manzoli, Lamberto; Simonetti, Valentina; Flacco, Maria Elena; Comparcini, Dania; Capasso, Lorenzo; Di Baldassarre, Angela; Eltaji Elfarouki, Ghaleb
2014-11-01
This multi-centre prospective field study evaluated whether peripheral venous catheter site of insertion influences the risk of catheter-related phlebitis. Potential predictors of phlebitis were also investigated. Millions of patients worldwide use peripheral venous catheters, which frequently cause local complications including phlebitis, infection and obstruction. Although phlebitis predictors have been broadly investigated, uncertainties remain on the potential effect of cannulation anatomical site, duration and the appropriate time for catheter removal. A prospective cohort design was carried out from January-June 2012. The clinical course of each patient who received a new peripheral venous catheter for any cause in five Italian hospitals was followed by trained nurses until catheter removal. The presence of phlebitis was assessed every 24 hours using the Visual Infusion Phlebitis score. Analyses were based upon multilevel mixed-effects regression. The final sample consisted of 1498 patients. The average time for catheters in situ was 65·6 hours and 23·6% of the catheters were in place beyond 96 hours. Overall phlebitis incidence was 15·4%, 94·4% of which were grade 1. The likelihood of phlebitis independently increased with increasing catheter duration, being highest after 96 hours. Compared with patients with catheter placed in the dorsum of the hand (22·8% of the sample), those with the catheter located in the antecubital fossa (34·1%) or forearm were less likely to have a phlebitis of any grade. Antecubital fossa and forearm veins may be preferential sites for peripheral venous cannulation. Our results support Centers for Disease Control and Prevention recommendations to replace catheters in adults no later than 96 hours. A relevant proportion of healthcare personnel did not adhere to such guidelines - more attention to this issue is required. © 2014 John Wiley & Sons Ltd.
The Toxicity of Inhaled Sulphur Mustard
2012-10-01
Index − CO – Cardiac Output − CvO2 – Mixed Venous Oxygenation − CVP – Central Venous Pressure − DO2 – Oxygen Delivery − dpMax – Maximum...in central venous pressure following exposure to HD: HD controls () and HD + NAC (). Data are expressed as mean ± SEM. UK UNCLASSIFIED Page 64 of...Respiratory rate (RR) Heart rate (HR) Expired CO2 Pulse oximetry Mean arterial pressure Central venous pressure Blood Chemistry (arterial and
Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM
Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi
2017-01-01
Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027
Samadi, Mahmood; Malaki, Majid; Ghaffari, Shamsi; Golshan Khalili, Roza
2012-01-01
Low Cardiac Output Syndrome (LCOS) contributes to postoperative morbidity and mortality. This article tries to find a predictive factor to interpret outcome after cardiac operation. In a cross-sectional study, 100 children with congenital heart disease undergoing cardiovascular surgery with cardiopulmonary bypass (CPB) without significant left-to-right shunt were selected. Arterial and central venous oxygen saturation values were measured via blood samples simultaneously obtained in 6-hr intervals for a total of 24-hr during postoperative period at hours 0, 6, 12, 18, and 24. Postoperative ventilation support (intubation period) and cardiovascular support were also obtained from the hospital records. Statistical analysis was later performed comparing the arterial-mixed venous oxygen saturation differences and durations of required ventilatory and cardiovascular support, both for the complicated and non-complicated patient groups. The data was processed with correlation Pearson and Mann-Whitney U tests in SPSS 15 software, P less than 0.05 was significant. Mortality following cardiac operation is 6% and complications may happen in 45% of the cases. The highest Arterial-mixed venous oxygen saturation difference occurred immediately post operation (up to 57%). These measures were high up to 18 hours in complicated and non-complicated groups (36% vs. 31% ; P< 0.05). This factor cannot predict prolongation of intubation period in patients (P > 0.05). Arterial-mixed venous oxygen saturation difference may be high as much as 57% or as low as 23%.These different measures, being higher up to 18 hours in complicated to non-complicated groups after 18 hours, can be related to tissue ischemia during surgery and cannot be discriminative.
Personal Computer System for Automatic Coronary Venous Flow Measurement
Dew, Robert B.
1985-01-01
We developed an automated system based on an IBM PC/XT Personal computer to measure coronary venous blood flow during cardiac catheterization. Flow is determined by a thermodilution technique in which a cold saline solution is infused through a catheter into the coronary venous system. Regional temperature fluctuations sensed by the catheter are used to determine great cardiac vein and coronary sinus blood flow. The computer system replaces manual methods of acquiring and analyzing temperature data related to flow measurement, thereby increasing the speed and accuracy with which repetitive flow determinations can be made.
Cambier, Carole; Clerbaux, Thierry; Amory, Hélène; Detry, Bruno; Florquin, Sandra; Marville, Vincent; Frans, Albert; Gustin, Pascal
2002-01-01
The study was carried out on healthy Friesian calves (n = 10) aged between 10 and 30 days. Hypochloremia and alkalosis were induced by intravenous administration of furosemide and isotonic sodium bicarbonate. The venous and arterial blood samples were collected repeatedly. 2,3-diphosphoglycerate (2,3-DPG), hemoglobin and plasmatic chloride concentrations were determined. The red blood cell chloride concentration was also calculated. pH, PCO2 and PO2 were measured in arterial and mixed venous blood. The oxygen equilibrium curve (OEC) was measured in standard conditions. The correspondence of the OEC to the arterial and mixed venous compartments was calculated, taking blood temperature, pH and PCO2 values into account. The oxygen exchange fraction (OEF%), corresponding to the degree of blood desaturation between the arterial and mixed venous compartments and the amount of oxygen released at the tissue level by 100 mL of blood (OEF Vol%) were calculated from the arterial and mixed venous OEC, combined with PO2 and hemoglobin concentration. Oxygen delivery (DO2) was calculated using the arterial oxygen content, the cardiac output measured by thermodilution, and the body weight of the animal. The oxygen consumption (VO2) was derived from the cardiac output, OEF Vol% and body weight values. Despite the plasma hypochloremia, the erythrocyte chloride concentration was not influenced by furosemide and sodium bicarbonate infusion. Due to the alkalosis-induced increase in the 2,3-DPG, the standard OEC was shifted to the right, allowing oxygen to dissociate from hemoglobin more rapidly. These changes opposed the increased affinity of hemoglobin for oxygen induced by alkalosis. Moreover, respiratory acidosis, hemoconcentration, and the slight decrease in the partial oxygen pressure in mixed venous blood (Pvo2) tended to improve the OEF Vol% and maintain the oxygen consumption in a physiological range while the cardiac output, and the oxygen delivery were significantly decreased. It may be concluded that, despite reduced oxygen delivery, oxygen consumption is maintained during experimentally induced hypochloremic alkalosis in healthy 10-30 day old calves.
Mixing problems in using indicators for measuring regional blood flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ushioda, E.; Nuwayhid, B.; Tabsh, K.
A basic requirement for using indicators for measuring blood flow is adequate mixing of the indicator with blood prior to sampling the site. This requirement has been met by depositing the indicator in the heart and sampling from an artery. Recently, authors have injected microspheres into veins and sampled from venous sites. The present studies were designed to investigate the mixing problems in sheep and rabbits by means of Cardio-Green and labeled microspheres. The indicators were injected at different points in the circulatory system, and blood was sampled at different levels of the venous and arterial systems. Results show themore » following: (a) When an indicator of small molecular size (Cardio-Green) is allowed to pass through the heart chambers, adequate mixing is achieved, yielding accurate and reproducible results. (b) When any indicator (Cardio-Green or microspheres) is injected into veins, and sampling is done at any point in the venous system, mixing is inadequate, yielding flow results which are inconsistent and erratic. (c) For an indicator or large molecular size (microspheres), injecting into the left side of the heart and sampling from arterial sites yield accurate and reproducible results regardless of whether blood is sampled continuously or intermittently.« less
Attempts at estimating mixed venous carbon dioxide tension by the single-breath method.
Ohta, H; Takatani, O; Matsuoka, T
1989-01-01
The single-breath method was originally proposed by Kim et al. [1] for estimating the blood carbon dioxide tension and cardiac output. Its reliability has not been proven. The present study was undertaken, using dogs, to compare the mixed venous carbon dioxide tension (PVCO2) calculated by the single-breath method with the PVCO2 measured in mixed venous blood, and to evaluate the influence of variations in the exhalation duration and the volume of expired air usually discarded from computations as the deadspace. Among the exhalation durations of 15, 30 and 45 s tested, the 15 s duration was found to be too short to obtain an analyzable O2-CO2 curve, but at either 30 or 45 s, the calculated values of PVCO2 were comparable to the measured PVCO2. A significant agreement between calculated and measured PVCO2 was obtained when the expired gas with PCO2 less than 22 Torr was considered as deadspace gas.
Vida, V L; Bhattarai, A; Speggiorin, S; Zanella, F; Stellin, G
2014-01-01
To observe how vacuum assisted venous drainage (VAVD) may influence the flow in a cardiopulmonary bypass circuit with different size of venous lines and cannulas. The experimental circuit was assembled to represent the cardiopulmonary bypass circuit routinely used during cardiac surgery. Wall suction was applied directly, modulated and measured into the venous reservoir. The blood flow was measured with a flow-meter positioned on the venous line. The circuit prime volume was replaced with group O date expired re-suspended red cells and Plasmalyte 148 to a hematocrit of 28% to 30%. In an open circuit with gravity siphon venous drain, angled cannulae drain more than straight ones regardless the amount of suction applied to the venous line (16 Fr straight cannula (S) drains 90 ml/min less than a 16 Fr angled (A) with a siphon gravity). The same flow can be obtained with lower cannula size and higher suction (i.e. 12 A with and -30 mmHg). Tables have been created to list how the flow varies according to the size of the cannulas, the size of the venous tubes, and the amount of suction applied to the system. Vacuum assisted venous drainage allows the use of smaller cannulae and venous lines to maintain a good venous return, which is very useful during minimally invasive approaches. The present study should be considered as a preliminary attempt to create a scientific-based starting point for a uniform the use of VAVD.
Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber
2011-12-01
Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.
To what extent might N2 limit dive performance in king penguins?
Fahlman, A; Schmidt, A; Jones, D R; Bostrom, B L; Handrich, Y
2007-10-01
A mathematical model was used to explore if elevated levels of N2, and risk of decompression sickness (DCS), could limit dive performance (duration and depth) in king penguins (Aptenodytes patagonicus). The model allowed prediction of blood and tissue (central circulation, muscle, brain and fat) N2 tensions (P(N2)) based on different cardiac outputs and blood flow distributions. Estimated mixed venous P(N2) agreed with values observed during forced dives in a compression chamber used to validate the assumptions of the model. During bouts of foraging dives, estimated mixed venous and tissue P(N2) increased as the bout progressed. Estimated mean maximum mixed venous P(N2) upon return to the surface after a dive was 4.56+/-0.18 atmospheres absolute (ATA; range: 4.37-4.78 ATA). This is equivalent to N2 levels causing a 50% DCS incidence in terrestrial animals of similar mass. Bout termination events were not associated with extreme mixed venous N2 levels. Fat P(N2) was positively correlated with bout duration and the highest estimated fat P(N2) occurred at the end of a dive bout. The model suggested that short and shallow dives occurring between dive bouts help to reduce supersaturation and thereby DCS risk. Furthermore, adipose tissue could also help reduce DCS risk during the first few dives in a bout by functioning as a sink to buffer extreme levels of N2.
Russell, W J; James, M F
2000-12-01
Theoretically, if the cardiac output were increased in the presence of a given intrapulmonary shunt, the arterial haemoglobin oxygen saturation (SaO2) should improve as the venous oxygen extraction per ml of blood decreases. To test this hypothesis, eight pigs were subjected to one-lung ventilation and adrenaline and isoprenaline infusions used to increase the cardiac output. The mixed venous oxygen, shunt fraction and oxygen consumption were measured. With both adrenaline and isoprenaline, although there was a small rise in mixed venous oxygen content, there was a fall in SaO2. With adrenaline, the mean shunt rose from 48% to 65%, the mean oxygen consumption rose from 126 ml/min to 134 ml/min and the mean SaO2 fell from 86.9% to 82.5%. With isoprenaline, the mean shunt rose from 45% to 59%, the mean oxygen consumption rose from 121 ml/min to 137 ml/min and the mean SaO2 fell from 89.5% to 84.7%. It is concluded that potential improvement in SaO2, which might occur from a catecholamine-induced increase in mixed venous oxygen content during one-lung ventilation, is more than offset by increased shunting and oxygen consumption which reduce SaO2.
Cade, W Todd; Nabar, Sharmila R; Keyser, Randall E
2004-05-01
The purpose of this study was to determine the reproducibility of the indirect Fick method for the measurement of mixed venous carbon dioxide partial pressure (P(v)CO(2)) and venous carbon dioxide content (C(v)CO(2)) for estimation of cardiac output (Q(c)), using the exponential rise method of carbon dioxide rebreathing, during non-steady-state treadmill exercise. Ten healthy participants (eight female and two male) performed three incremental, maximal exercise treadmill tests to exhaustion within 1 week. Non-invasive Q(c) measurements were evaluated at rest, during each 3-min stage, and at peak exercise, across three identical treadmill tests, using the exponential rise technique for measuring mixed venous PCO(2) and CCO(2) and estimating venous-arterio carbon dioxide content difference (C(v-a)CO(2)). Measurements were divided into measured or estimated variables [heart rate (HR), oxygen consumption (VO(2)), volume of expired carbon dioxide (VCO(2)), end-tidal carbon dioxide (P(ET)CO(2)), arterial carbon dioxide partial pressure (P(a)CO(2)), venous carbon dioxide partial pressure ( P(v)CO(2)), and C(v-a)CO(2)] and cardiorespiratory variables derived from the measured variables [Q(c), stroke volume (V(s)), and arteriovenous oxygen difference ( C(a-v)O(2))]. In general, the derived cardiorespiratory variables demonstrated acceptable (R=0.61) to high (R>0.80) reproducibility, especially at higher intensities and peak exercise. Measured variables, excluding P(a)CO(2) and C(v-a)CO(2), also demonstrated acceptable (R=0.6 to 0.79) to high reliability. The current study demonstrated acceptable to high reproducibility of the exponential rise indirect Fick method in measurement of mixed venous PCO(2) and CCO(2) for estimation of Q(c) during incremental treadmill exercise testing, especially at high-intensity and peak exercise.
Patel, Darshan; Ray, Charles E.; Lokken, R. Peter; Bui, James T.; Lipnik, Andrew J.; Gaba, Ron C.
2016-01-01
Surgically placed dialysis access is an important component of dialysis replacement therapy. The vast majority of patients undergoing dialysis will have surgically placed accesses at some point in the course of their disease, and for many patients these accesses may represent their definitive renal replacement option. Most, if not all, arteriovenous fistulae and grafts will require interventions at some point in time. Percutaneous angioplasty is the typical first treatment performed for venous stenoses, with stents and stent grafts being reserved for patients in whom angioplasty and surgical options are exhausted. In some salvage situations, stent graft placement may be the only or best option for patients. This article describes, using case illustrations, placement of stent grafts in such patients; a focus will also be made on the techniques utilized in such salvage situations. PMID:27011426
Malone, P Colm; Agutter, P S
2009-08-01
According to the valve cusp hypoxia hypothesis (VCHH), deep venous thrombosis is caused by sustained non-pulsatile (streamline) venous blood flow. This leads to hypoxemia in the valve pockets; hypoxic injury to the inner (parietalis) endothelium of the cusp leaflets activates the elk-1/egr-1 pathway, leading to leukocyte and platelet swarming at the site of injury and, potentially, blood coagulation. Here, we propose an extension of the VCHH to account for chronic venous insufficiency. First, should the foregoing events not proceed to frank thrombogenesis, the valves may nevertheless be chronically injured and become incompetent. Serial incompetence in lower limb valves may then generate ''passive'' venous hypertension. Second, should ostial valve thrombosis obstruct venous return from muscles via tributaries draining into the femoral vein, as Virchow illustrated, ''active'' venous hypertension may supervene: muscle contraction would force the blood in the vessels behind the blocked ostial valves to re-route. Passive or active venous hypertension opposes return flow, leading to luminal hypoxemia and vein wall distension, which in turn may impair vasa venarum perfusion; the resulting mural endothelial hypoxia would lead to leukocyte invasion of the wall and remodelling of the media. We propose that varicose veins result if gross active hypertension stretches the valve ''rings'', rendering attached valves incompetent caudad to obstructed sites, replacing normal centripetal flow in perforating veins with centrifugal flow and over-distending those vessels. We also discuss how hypoxemia-related venous/capillary wall lesions may lead to accumulation of leukocytes, progressive blockage of capillary blood flow, lipodermosclerosis and skin ulceration.
Beta-Blockers: An Abstracted Bibliography.
1989-04-04
on subjects in the supine position. Blood flow was measured by venous occlusion plethys- mography. Prugs were administered via indwelling catheter (one...PROCEDURES: Noninvasive measuremert of maximum oxygen intake, invasive measurement of systemic and pulmonary arterial pressures, arterial and mixed venous ...ratio was approximately 0.1:1. Central nervous system-related effects associated with propranolol and metoprolol appear to be the result of high brain
Fluid therapy for septic shock resuscitation: which fluid should be used?
Corrêa, Thiago Domingos; Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Silva, Eliézer; de Assuncao, Murillo Santucci Cesar
2015-01-01
Early resuscitation of septic shock patients reduces the sepsis-related morbidity and mortality. The main goals of septic shock resuscitation include volemic expansion, maintenance of adequate tissue perfusion and oxygen delivery, guided by central venous pressure, mean arterial pressure, mixed or central venous oxygen saturation and arterial lactate levels. An aggressive fluid resuscitation, possibly in association with vasopressors, inotropes and red blood cell concentrate transfusion may be necessary to achieve those hemodynamic goals. Nonetheless, even though fluid administration is one of the most common interventions offered to critically ill patients, the most appropriate type of fluid to be used remains controversial. According to recently published clinical trials, crystalloid solutions seem to be the most appropriate type of fluids for initial resuscitation of septic shock patients. Balanced crystalloids have theoretical advantages over the classic solutions, but there is not enough evidence to indicate it as first-line treatment. Additionally, when large amounts of fluids are necessary to restore the hemodynamic stability, albumin solutions may be a safe and effective alternative. Hydroxyethyl starches solutions must be avoided in septic patients due to the increased risk of acute renal failure, increased need for renal replacement therapy and increased mortality. Our objective was to present a narrative review of the literature regarding the major types of fluids and their main drawbacks in the initial resuscitation of the septic shock patients.
YAG laser in the treatment of hemorrhoids: a report of 700 cases
NASA Astrophysics Data System (ADS)
Liu, Jian-xun; Zhang, Xinrong
1993-03-01
The results of treating hemorrhoids in 700 cases with a YAG laser knife is reported. Since 1988, the author introduced the YAG laser into the treatment of various kinds of hemorrhoids. The satisfactory results were achieved with 100% cure rate. Some related problems also are discussed in this paper. Hemorrhoid is a kind of common disease. It usually appears in the superior or inferior rectal venous plexus covered with mucosa. The hemorrhoids are divided into internal, external, and mixed types according to their location and origination. The internal hemorrhoid is superior to the dentate line and caused by varicosity of superior rectal venous plexus covered with mucosa, the most common presentation is a bleeding and prolapse mass out of the anus. The external hemorrhoid arises from varicosity of inferior rectal venous plexus, the most important clinical finding is a painful mass covered with skin of the anal canal. The characteristics of mixed type are the combination of the two types as mentioned above.
Cottle, Daniel; Mousdale, Stephen; Waqar-Uddin, Haroon; Tully, Redmond; Taylor, Benjamin
2016-02-01
Transferring the theoretical aspect of continuous renal replacement therapy to the bedside and delivering a given "dose" can be difficult. In research, the "dose" of renal replacement therapy is given as effluent flow rate in ml kg -1 h -1 . Unfortunately, most machines require other information when they are initiating therapy, including blood flow rate, pre-blood pump flow rate, dialysate flow rate, etc. This can lead to confusion, resulting in patients receiving inappropriate doses of renal replacement therapy. Our aim was to design an excel calculator which would personalise patient's treatment, deliver an effective, evidence-based dose of renal replacement therapy without large variations in practice and prolong filter life. Our calculator prescribes a haemodialfiltration dose of 25 ml kg -1 h -1 whilst limiting the filtration fraction to 15%. We compared the episodes of renal replacement therapy received by a historical group of patients, by retrieving their data stored on the haemofiltration machines, to a group where the calculator was used. In the second group, the data were gathered prospectively. The median delivered dose reduced from 41.0 ml kg -1 h -1 to 26.8 ml kg -1 h -1 with reduced variability that was significantly closer to the aim of 25 ml kg -1 .h -1 ( p < 0.0001). The median treatment time increased from 8.5 h to 22.2 h ( p = 0.00001). Our calculator significantly reduces variation in prescriptions of continuous veno-venous haemodiafiltration and provides an evidence-based dose. It is easy to use and provides personal care for patients whilst optimizing continuous veno-venous haemodiafiltration delivery and treatment times.
Lapertosa, G.; Baracchini, P.; Fulcheri, E.; Tanzi, R.
1989-01-01
In postsurgical staging of colorectal adenocarcinomas, it is sometimes difficult to determine the range of possible venous spread. Distinguishing between the extramural veins (especially when the neoplastic embolus takes up the whole lumen and the endothelium cannot be identified) and the smallest extramural lymph nodes (when they are completely replaced by metastatic carcinoma, leaving the capsule alone) is also difficult. This work proposes a more precise definition of true venous invasion to improve histopathologic staging. Immunohistochemical techniques employing commercial antibodies against Factor VIII RAG, with and without enzymatic digestion, and UEA I lectin for residual endothelium detection, were applied, as well as antibodies against vimentin, desmin, and alpha sm-1 actin to detect wall components. The immunohistochemical evaluation of colorectal adenocarcinomas, in particular by anti-alpha sm-1 actin antibodies, permitted a reliable morphologic distinction of the true venous invasion. This factor proved to be relevant for survival rate prediction. Images Figure 1 Figure 2 PMID:2817085
Preliminary clinical investigations of a new noninvasive venous pulse oximeter
NASA Astrophysics Data System (ADS)
Chan, Daniel; Smith, Peter R.; Caine, Michael P.; Spyt, Tomasz; Boehm, Maria; Machin, David
2003-10-01
For decades, the monitoring of mixed venous oxygen saturation, SvO2 has been performed invasively using fibre-optic catheters. This procedure is not without risk as complications may arise from catheterisation. The group has devised a new non-invasive venous oximetry method which involves inducing regular modulations of the venous blood volume and associated measurement of those modulations using optical means. A clinical investigation was conducted in Glenfield Hospital, UK to evaluate the sensitivity of the new technique to haemodynamic changes such as Cardiac Output (CO) in intraoperative and postoperative cardiac patients. Preliminary trials on patients recovering from cardiac surgery yielded an average correlation of r = 0.72 between CO at different Intra Aortic Balloon Pump (IABP) augmentation levels and SvO2 measured by the new venous oximeter. In intraoperative patients undergoing off-pump cardiac surgery, SvO2 recorded by the new technique responded to unplanned events such as a cardiac arrest. CONCLUSION: The new venous oximetry technique is a promising technique which responds to haemodynamic changes such as CO and with further development might offer an alternative means of monitoring SvO2 non-invasively.
Low-molecular-weight heparin for thromboprophylaxis.
Camporese, Giuseppe; Bernardi, Enrico
2009-09-01
Venous thromboembolism represents a potentially threatening complication in surgical and medical patients. Thromboprophylaxis showed a significant reduction of venous thromboembolic events, and low-molecular-weight heparins have been considered the standardized prophylactic regimen for a long time. The purpose of this review is to provide updated evidence on the use of low-molecular-weight heparins for prevention of venous thromboembolism after the publication of the latest American College of Chest Physicians Evidence-Based Clinical Practice Guidelines on antithrombotic and thrombolytic therapy. Low-molecular-weight heparins, used as comparator or investigational drug, have been investigated in several studies not included in the analysis of the latest American College of Chest Physicians Guidelines on Antithrombotic and Thrombolytic Therapy. Data gathered from studies published from December 2007 up to May 2009 dealing with surgical and medical patients have been collected and discussed. Low-molecular-weight heparins are expanding their application, but progressively they will be replaced by other new antithrombotics for the prophylaxis of venous thromboembolism. Surgical patients undergo a more concerted approach to thromboprophylaxis than medical patients. Future research should aim at improving prophylaxis in the latter setting in order to significantly reduce the rate of venous thromboembolic events.
Wirkus, Dorota; Jakubus, Aleksandra; Owczuk, Radosław; Stepnowski, Piotr; Paszkiewicz, Monika
2017-02-01
Continous renal replacement therapy (CRRT) is particularly recommended for septic shock patients in intensive care units. The CRRT technique used most frequently is high volume continuous veno-venous haemofiltration. It provides a high rate of clearance of uremic toxins and inflammatory cytokines. However, it should also be taken into account that substances important for homeostasis may be concurrently unintentionally removed. Accordingly, water-soluble vitamins can be removed during continuous renal replacement therapy, and the estimate of the loss is critical to ensure appropriate supplementation. The aim of this work was to develop a simple methodology for a purification step prior to the LC-MS/MS determination of water-soluble vitamins in ultrafiltrate samples. For this purpose, two types of resin and a mix of resins were used as sorbents for the purification step. Moreover, parameters such as the amount of resin and the extraction time were optimized. The LC-MS/MS method was developed and validated for final determination of 11 vitamins. The results demonstrated the high purification capability of DEAE Sephadex resin with recoveries between 65 and 101% for water-soluble vitamins from ultrafiltrate samples. An optimized method was applied to assess the loss of B-group vitamins in patients after 24h of renal replacement therapy. The loss of vitamins B2, B6 pyridoxamine, B6 pyridoxal, B7, B1, and B5 in ultrafiltrates was similar in all patients. In the native ultrafiltrates, vitamins B6 pyridoxine, B9 and B12 were not detected. Copyright © 2016 Elsevier B.V. All rights reserved.
Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study
NASA Astrophysics Data System (ADS)
Esenaliev, Rinat O.; Larina, Irina V.; Larin, Kirill V.; Deyo, Donald J.; Motamedi, Massoud; Prough, Donald S.
2002-08-01
Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.
Effects of acute hypoxia on cardiopulmonary responses to head-down tilt
NASA Technical Reports Server (NTRS)
Loeppky, J. A.; Luft, U. C.; Scotto, P.; Chick, T. W.
1990-01-01
Six male subjects were exposed on two separate occasions to simulated microgravity with 28 deg head-down tilt (HD) for 1 h with baseline followed by recovery at + 17 deg head-up. Pulmonary ventilation, gas exchange, spirometry, and central and cerebral blood flow characteristics were compared while breathing ambient air and reduced F(I)O2 equivalent to 14,828 ft. With hypoxia (HY), the increased tidal volume served to attenuate the drop in arterial saturation by reducing deadspace ventilation. Arterial and mixed venous PO2, values, estimated from peripheral venous samples and cardiac output (CO), were both maintained during HD in HY. Mixed venous PO2 was elevated by an increase in CO associated with a reduction in systemic resistance. Changes in spirometric indices during HD were not accentuated by HY, making the presence of interstitial edema unlikely. Cerebral flow and resistance showed minor reductions with HD. Tissue oxygenation and cardiopulmonary function were not notably effected by HD during HY, but a combination of these two stressors may predispose subjects to subsequent orthostatic intolerance during initial recovery.
Wollina, Uwe; Heinig, Birgit; Stelzner, Christian; Hansel, Gesina; Schönlebe, Jacqueline; Tchernev, Georgi; Lotti, Torello
2018-01-25
Leg ulcers are a burden to patients, their families and society. The second most common cause of chronic leg ulcers is the mixed arterio-venous type. An 80-year-old female patient presented to our department due to painful enlarging chronic leg ulcer of mixed arteriovenous origin on her left lower leg. She suffered from peripheral arterial occlusive disease stage I and chronic venous insufficiency Widmer grade IIIa, and a number of comorbidities. The aim of our ulcer treatment was a complete and stable wound closure that was hampered by arterial occlusion, exposed tendon, and renal insiffuciency. To improve the prognosis for ulcer surgery, we performed percutaneous transluminal angioplasty, transcutaneous CO 2 and deep ulcer shaving. The wound was closed by sandwich transplantation using elastin-collagen dermal template and meshed split skin graft. She had a 100% graft take with rapid reduction of severe wound pain. Complex approaches are necessary, to gain optimum results in leg ulcer therapy in mixed leg ulcers. Therapeutic nihilism should be abandonend.
24 CFR 891.855 - Replacement reserves.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Partnerships and Mixed-Finance Development for Supportive Housing for the Elderly or Persons with Disabilities § 891.855 Replacement reserves. (a) The mixed-finance owner shall establish and maintain a replacement... requirements of 24 CFR 891.405. (b) The mixed-finance owner may obtain a disbursement from the reserve only if...
Self-Expanding, Tough Biodegradable Elastomers for Wound Stasis
2015-08-06
results were incon- clusive in mixed (arterial and venous)17 and arterial bleed- ing.18,19 Likewise, QuikClot Zeolite granules were effective in venous...177Y182. 17. Alam HB, Chen Z, Jaskille A, et al. Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin...reactions of hemostatic agents, such as early- generation granular zeolite , have resulted in patient injury.20,21 In this study, the reaction between
Pathogenesis of DIC in Strain 13 Guinea Pigs Infected with Pichinde Virus.
1992-01-31
598. 21. Leeksma OC, Meijer-Huizinga F, Stoepman-van Dalen EA et al. Fibrinopep- tide A in urine from patients with venous thromboembolism...withdrawn initially at the emergency room from femoral vein and subsequently from an antecubital vein at ICU. Nine ml of venous blood was mixed with I ml of...observed in trauma patients may be related to the plasmic degradation of soluble crosslinked fibrin rather than the actual fibrinolysis of thrombus
Ito, Hiroki; Murata, Masaya; Ide, Yujiro; Sugano, Mikio; Kanno, Kazuyoshi; Imai, Kenta; Ishido, Motonori; Fukuba, Ryohei; Sakamoto, Kisaburo
2016-01-01
OBJECTIVES Fontan candidates with mixed totally anomalous pulmonary venous connection often have postoperative pulmonary venous obstruction after cavopulmonary anastomosis. Because some pulmonary venous obstructions have no intimal hypertrophy at reoperation, we considered such pulmonary venous obstructions to be caused by 3D deformities arising from dissection or mobilization of the vessels, and hypothesized that keeping the pulmonary venous branches in a natural position could avoid such obstruction. Here, we evaluated a modified hemi-Fontan strategy consisting of minimal dissection with no division of vessels and patch separation between systemic and pulmonary venous flow. METHODS We retrospectively reviewed clinical records of infants with a functional single ventricle and supracardiac anomalous pulmonary venous connection who had undergone this procedure between 2002 and 2012. RESULTS Nine infants underwent this procedure (median age, 5.6 months; range 3.2–30), all with right atrial isomerism and several pulmonary venous branches directly and separately connecting to the superior vena cava. In 5 patients, all pulmonary veins drained into the superior vena cava; in 1, the right pulmonary veins drained into the superior vena cava and in 3, a pulmonary venous branch drained into the superior vena cava. The median follow-up was 6.9 years (0.8–13 years). Three patients underwent reoperation for postoperative pulmonary venous obstruction caused by intimal hypertrophy; however, we confirmed no pulmonary venous obstruction caused by 3D deformities on the pulmonary venous branches connecting separately to the superior vena cava. Although 2 patients were effectively relieved from pulmonary venous obstruction, 1 died due to recurrent pulmonary venous obstruction. There was no late death and no sinus-node dysfunction. Eight patients underwent successful Fontan operation and catheterization. The median interval from the Fontan operation to the latest catheterization was 3.7 years (0.9–3.7 years). The median arterial oxygen saturation was 94% (91–97%) and the central venous pressure was 12 mmHg (8–14 mmHg); no deficiency of pulmonary arteries and veins was noted. CONCLUSIONS For patients with functional single ventricle and anomalous pulmonary venous connections to the superior vena cava, our novel strategy of second-stage palliation could avoid postoperative pulmonary venous obstruction caused by 3D deformities, but may not eliminate pulmonary venous obstruction caused by intimal hypertrophy. PMID:26860898
NASA Astrophysics Data System (ADS)
Ryou, Hong Sun; Kim, Soyoon; Ro, Kyoungchul
2013-02-01
For patients with renal failure, renal replacement therapies are needed. Hemodialysis is a widely used renal replacement method to remove waste products. It is important to improve the patency rate of the vascular access for efficient dialysis. Since some complications such as an intimal hyperplasia are associated with the flow pattern, the hemodynamics in the vascular access must be considered to achieve a high patency rate. In addition, the blood flow from an artificial kidney affects the flow in the vascular access. Generally, the clinical techniques of hemodialysis such as the catheter angle or dialysis dose have been set up empirically. In this study, a numerical analysis is performed on the effect of the catheter angle on the flow in the graft. Blood is assumed to be a non-Newtonian fluid. According to the high average wall shear stress value, the leucocytes and platelets can be activated not only at the arterial anastomosis, but also at the bottom of the venous graft, when the catheter angle is not zero. For a catheter angle less than five degrees, there is a low shear and high oscillatory shear index region that appears at the venous graft and the venous anastomosis. Thus, a catheter angle less than five degrees should be avoided to prevent graft failure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siegel, R.S.; Rae, J.L.; Ryan, N.L.
Five hundred indium-111 labeled platelet imaging studies (387 donor and 113 autologous) were performed postoperatively in 473 patients who had undergone total hip replacement, total knee replacement, or internal fixation of a hip fracture to detect occult deep venous thrombosis. All patients had been anticoagulated prophylactically with aspirin, warfarin sodium (Coumadin), or dextran. Thirty-four possible cases of proximal deep venous thrombosis were identified in 28 asymptomatic patients. To verify the scan results, 31 venograms were performed in 25 patients (three refused). In 21 of 31 cases, totally occlusive thrombi were detected; in 5 cases, partially occlusive thrombi were detected; inmore » 5 cases, no thrombus was seen. No patient who had a negative scan nor any patient who had a verified positive scan (and received appropriate heparin therapy) subsequently developed symptoms or signs of pulmonary embolism. One hundred forty-one indium study patients also underwent Doppler ultrasonography/impedance plethysmography (Doppler/IPG) as a comparative non-invasive technique. In 137 cases, the results of the indium study and Doppler/IPG studies were congruent. The indium study had no false negative results that were detected by Doppler/IPG. No patient had any clinically evident toxicity. These results suggest that indium-111 labeled platelet scanning is a safe, noninvasive means for identifying DVT in high risk patients.« less
Schober, Andrew; Feiner, John R; Bickler, Philip E; Rollins, Mark D
2018-01-01
Cerebral oximetry (cerebral oxygen saturation; ScO2) is used to noninvasively monitor cerebral oxygenation. ScO2 readings are based on the fraction of reduced and oxidized hemoglobin as an indirect estimate of brain tissue oxygenation and assume a static ratio of arterial to venous intracranial blood. Conditions that alter cerebral blood flow, such as acute changes in PaCO2, may decrease accuracy. We assessed the performance of two commercial cerebral oximeters across a range of oxygen concentrations during normocapnia and hypocapnia. Casmed FORE-SIGHT Elite (CAS Medical Systems, Inc., USA) and Covidien INVOS 5100C (Covidien, USA) oximeter sensors were placed on 12 healthy volunteers. The fractional inspired oxygen tension was varied to achieve seven steady-state levels including hypoxic and hyperoxic PaO2 values. ScO2 and simultaneous arterial and jugular venous blood gas measurements were obtained with both normocapnia and hypocapnia. Oximeter bias was calculated as the difference between the ScO2 and reference saturation using manufacturer-specified weighting ratios from the arterial and venous samples. FORE-SIGHT Elite bias was greater during hypocapnia as compared with normocapnia (4 ± 9% vs. 0 ± 6%; P < 0.001). The INVOS 5100C bias was also lower during normocapnia (5 ± 15% vs. 3 ± 12%; P = 0.01). Hypocapnia resulted in a significant decrease in mixed venous oxygen saturation and mixed venous oxygen tension, as well as increased oxygen extraction across fractional inspired oxygen tension levels (P < 0.0001). Bias increased significantly with increasing oxygen extraction (P < 0.0001). Changes in PaCO2 affect cerebral oximeter accuracy, and increased bias occurs with hypocapnia. Decreased accuracy may represent an incorrect assumption of a static arterial-venous blood fraction. Understanding cerebral oximetry limitations is especially important in patients at risk for hypoxia-induced brain injury, where PaCO2 may be purposefully altered.
A troubled beginning: evolving concepts of an old arrhythmia.
Hanon, Sam; Shapiro, Michael; Schweitzer, Paul
2005-07-01
The development of the sphygmograph in the nineteenth century marked the beginning of graphic registration of the arterial and venous pulse. Mackenzie, among other investigators, used this technique to study cardiac rhythm. In the early 20th century, Einthoven developed the electrocardiogram, which replaced the less sophisticated arterial and venous registrations of cardiac events and allowed for more detailed arrhythmia analysis. Interestingly, the early study of cardiac arrhythmias was obscured by misinterpretation. Specifically, atrial fibrillation stands out as a rhythm that was extensively studied though misconstrued in its early history. What follows is an in-depth consideration of the original investigations and evolving theories of this important arrhythmia.
Lindskog, Henrik; Kim, Yung Hae; Jelin, Eric B.; Kong, Yupeng; Guevara-Gallardo, Salvador; Kim, Tyson N.; Wang, Rong A.
2014-01-01
Coordinated arterial-venous differentiation is crucial for vascular development and function. The origin of the cardinal vein (CV) in mammals is unknown, while conflicting theories have been reported in chick and zebrafish. Here, we provide the first molecular characterization of endothelial cells (ECs) expressing venous molecular markers, or venous-fated ECs, within the emergent dorsal aorta (DA). These ECs, expressing the venous molecular markers Coup-TFII and EphB4, cohabited the early DA with ECs expressing the arterial molecular markers ephrin B2, Notch and connexin 40. These mixed ECs in the early DA expressed either the arterial or venous molecular marker, but rarely both. Subsequently, the DA exhibited uniform arterial markers. Real-time imaging of mouse embryos revealed EC movement from the DA to the CV during the stage when venous-fated ECs occupied the DA. We analyzed mutants for EphB4, which encodes a receptor tyrosine kinase for the ephrin B2 ligand, as we hypothesized that ephrin B2/EphB4 signaling may mediate the repulsion of venous-fated ECs from the DA to the CV. Using an EC quantification approach, we discovered that venous-fated ECs increased in the DA and decreased in the CV in the mutants, whereas the rest of the ECs in each vessel were unaffected. This result suggests that the venous-fated ECs were retained in the DA and missing in the CV in the EphB4 mutant, and thus that ephrin B2/EphB4 signaling normally functions to clear venous-fated ECs from the DA to the CV by cell repulsion. Therefore, our cellular and molecular evidence suggests that the DA harbors venous progenitors that move to participate in CV formation, and that ephrin B2/EphB4 signaling regulates this aortic contribution to the mammalian CV. PMID:24550118
2015-03-01
statistically significant increase in systemic vascular resistance compared to control, but not whole blood, with a concomitant decrease in cardiac...increasing blood pressure as well as sys- temic vascular resistance in a hypovolemic hemorrhagic swine model.18 The primary hypothesis of this study is...output, sys- temic vascular resistance , mixed venous oxygen satura- tion, central venous pressure, pulmonary artery pressure, and core temperature. The
Measurement of T1 of human arterial and venous blood at 7T.
Rane, Swati D; Gore, John C
2013-04-01
Techniques for measuring cerebral perfusion require accurate longitudinal relaxation (T1) of blood, an MRI parameter that is field dependent. T1 of arterial and venous human blood was measured at 7T using three different sources - pathology laboratory, blood bank and in vivo. The T1 of venous blood was measured from sealed samples from a pathology lab and in vivo. Samples from a blood bank were oxygenated and mixed to obtain different physiological concentrations of hematocrit and oxygenation. T1 relaxation times were estimated using a three-point fit to a simple inversion recovery equation. At 37°C, the T1 of blood at arterial pO2 was 2.29±0.1s and 2.07±0.12 at venous pO2. The in vivo T1 of venous blood, in three subjects, was slightly longer at 2.45±0.11s. T1 of arterial and venous blood at 7T was measured and found to be significantly different. The T1 values were longer in vivo than in vitro. While the exact cause for the discrepancy is unknown, the additives in the blood samples, degradation during experiment, oxygenation differences, and the non-stagnant nature of blood in vivo could be potential contributors to the lower values of T1 in the venous samples. Copyright © 2013 Elsevier Inc. All rights reserved.
Energy content in dried leaf litter of some oaks and mixed mesophytic species that replace oaks
Aaron D. Stottlemeyer; G. Geoff Wang; Patrick H. Brose; Thomas A. Waldrop
2010-01-01
Mixed-mesophytic hardwood tree species are replacing upland oaks in vast areas of the Eastern United States deciduous forest. Some researchers have suggested that the leaf litter of mixed-mesophytic, oak replacement species renders forests less flammable where forest managers wish to restore a natural fire regime. We performed chemical analyses on dried leaf litter...
Segmental Blood Flow and Hemodynamic State of Lymphedematous and Nonlymphedematous Arms
Montgomery, Leslie D.; Dietrich, Mary S.; Armer, Jane M.; Stewart, B. R.
2011-01-01
Abstract Background Findings regarding the influence hemodynamic factors, such as increased arterial blood flow or venous abnormalities, on breast cancer treatment-related lymphedema are mixed. The purpose of this study was to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal individuals without lymphedema. Methods and Results A Tetrapolar High Resolution Impedance Monitor and Cardiotachometer were used to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal volunteers. Average arterial blood flow in lymphedema-affected arms was higher than that in arms of healthy normal volunteers or in contralateral nonlymphedema affected arms. Time of venous outflow period of blood flow pulse was lower in lymphedema-affected arms than in healthy normal or lymphedema nonaffected arms. Amplitude of the venous component of blood flow pulse signal was lower in lymphedema-affected arms than in healthy or lymphedema nonaffected arms. Index of venular tone was also lower in lymphedema-affected arms than healthy or lymphedema nonaffected arms. Conclusions Both arterial and venous components may be altered in the lymphedema-affected arms when compared to healthy normal arms and contralateral arms in the breast cancer survivors. PMID:21417765
Floren, H K; Sischo, W M; Crudo, C; Moore, D A
2016-09-01
The Brix refractometer is used on dairy farms and calf ranches for colostrum quality (estimation of IgG concentration), estimation of serum IgG concentration in neonatal calves, and nonsalable milk evaluation of total solids for calf nutrition. Another potential use is to estimate the total solids concentrations of milk replacer mixes as an aid in monitoring feeding consistency. The purpose of this study was to evaluate the use of Brix refractometers to estimate total solids in milk replacer solutions and evaluate different replacer mixes for osmolality. Five different milk replacer powders (2 milk replacers with 28% crude protein and 25% fat and 3 with 22% crude protein and 20% fat) were mixed to achieve total solids concentrations from approximately 5.5 to 18%, for a total of 90 different solutions. Readings from both digital and optical Brix refractometers were compared with total solids. The 2 types of refractometers' readings correlated well with one another. The digital and optical Brix readings were highly correlated with the total solids percentage. A value of 1.08 to 1.47 would need to be added to the Brix reading to estimate the total solids in the milk replacer mixes with the optical and digital refractometers, respectively. Osmolality was correlated with total solids percentage of the mixes, but the relationship was different depending on the type of milk replacer. The Brix refractometer can be beneficial in estimating total solids concentration in milk replacer mixes to help monitor milk replacer feeding consistency. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Fareed, Jawed; Adiguzel, Cafer; Thethi, Indermohan
2011-03-28
The prevention of venous thromboembolism has been identified as a leading priority in hospital safety. Recommended parenteral anticoagulant agents with different indications for the prevention and treatment of venous thromboembolism include unfractionated heparin, low-molecular-weight heparins and fondaparinux. Prescribing decisions in venous thromboembolism management may seem complex due to the large range of clinical indications and patient types, and the range of anticoagulants available. MEDLINE and EMBASE databases were searched to identify relevant original articles. Low-molecular-weight heparins have nearly replaced unfractionated heparin as the gold standard antithrombotic agent. Low-molecular-weight heparins currently available in the US are enoxaparin, dalteparin, and tinzaparin. Each low-molecular-weight heparin is a distinct pharmacological entity with different licensed indications and available clinical evidence. Enoxaparin is the only low-molecular-weight heparin that is licensed for both venous thromboembolism prophylaxis and treatment. Enoxaparin also has the largest body of clinical evidence supporting its use across the spectrum of venous thromboembolism management and has been used as the reference standard comparator anticoagulant in trials of new anticoagulants. As well as novel oral anticoagulant agents, biosimilar and/or generic low-molecular-weight heparins are now commercially available. Despite similar anticoagulant properties, studies report differences between the branded and biosimilar and/or generic agents and further clinical studies are required to support the use of biosimilar low-molecular-weight heparins. The newer parenteral anticoagulant, fondaparinux, is now also licensed for venous thromboembolism prophylaxis in surgical patients and the treatment of acute deep-vein thrombosis; clinical experience with this anticoagulant is expanding. Parenteral anticoagulants should be prescribed in accordance with recommended dose regimens for each clinical indication, based on the available clinical evidence for each agent to assure optimal safety and efficacy.
In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients.
Pekkan, Kerem; Aka, Ibrahim Basar; Tutsak, Ece; Ermek, Erhan; Balim, Haldun; Lazoglu, Ismail; Turkoz, Riza
2018-03-11
Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation. Blade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios. The prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow. Our experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Chu, E; Haller, D; Cartwright, T; Twelves, C; Cassidy, J; Sun, W; Saif, M W; McKenna, E; Lee, S; Schmoll, H-J
2014-03-18
Central venous access devices in fluoropyrimidine therapy are associated with complications; however, reliable data are lacking regarding their natural history, associated complications and infusion pump performance in patients with metastatic colorectal cancer. We assessed device placement, use during treatment, associated clinical outcomes and infusion pump performance in the NO16966 trial. Device replacement was more common with FOLFOX-4 (5-fluorouracil (5-FU)+oxaliplatin) than XELOX (capecitabine+oxaliplatin) (14.1% vs 5.1%). Baseline device-associated events and post-baseline removal-/placement-related events occurred more frequently with FOLFOX-4 than XELOX (11.5% vs 2.4% and 8.5% vs 2.1%). Pump malfunctions, primarily infusion accelerations in 16% of patients, occurred within 1.6-4.3% of cycles. Fluoropyrimidine-associated grade 3/4 toxicity was increased in FOLFOX-4-treated patients experiencing a malfunction compared with those who did not (97 out of 155 vs 452 out of 825 patients), predominantly with increased grade 3/4 neutropenia (53.5% vs 39.8%). Febrile neutropenia rates were comparable between patient cohorts±malfunction. Efficacy outcomes were similar in patient cohorts±malfunction. Central venous access device removal or replacement was common and more frequent in patients receiving FOLFOX-4. Pump malfunctions were also common and were associated with increased rates of grade 3/4 haematological adverse events. Oral fluoropyrimidine-based regimens may be preferable to infusional 5-FU based on these findings.
The current status of prophylactic replacement therapy in children and adults with haemophilia.
Ljung, Rolf; Gretenkort Andersson, Nadine
2015-06-01
Initiating prophylactic treatment at an early age is considered to be the optimal form of therapy for a child with haemophilia A or B. The pioneering long term experiences of prophylactic treatment from Sweden and The Netherlands demonstrated the benefit of prophylaxis in retrospective and observational studies. Decades later, these benefits were confirmed in a randomized controlled study in USA. We review the current status of prophylactic replacement therapy of haemophilia in children, adolescents, adults and the elderly. Prophylaxis should begin at an early age and there are arguments for continuing it into adulthood. The dose of prophylaxis is dependent on the goal of treatment, economic resources and venous access and should be tailored individually. Starting the first exposures to clotting factor concentrates as prophylactic treatment, instead of on-demand in response to a bleed, may decrease the frequency of inhibitors in patients with haemophilia A. Novel longer-acting products are being introduced that could be helpful for patients with difficult venous access and enable higher trough levels. © 2015 John Wiley & Sons Ltd.
Sekaran, Alan; Palaniswamy, Murthi; Balaraju, Sivagnanaprakash
2015-01-01
Environmental and economic factors increasingly encourage higher utility of industrial by-products. The basic objective of this study was to identify alternative source for good quality aggregates which is depleting very fast due to fast pace of construction activities in India. EAF oxidizing slag as a by-product obtained during the process in steel making industry provides great opportunity to utilize it as an alternative to normally available coarse aggregates. The primary aim of this research was to evaluate the physical, mechanical, and durability properties of concrete made with EAF oxidizing slag in addition to supplementary cementing material fly ash. This study presents the experimental investigations carried out on concrete grades of M20 and M30 with three mixes: (i) Mix A, conventional concrete mix with no material substitution, (ii) Mix B, 30% replacement of cement with fly ash, and (iii) Mix C, 30% replacement of cement with fly ash and 50% replacement of coarse aggregate with EAF oxidizing slag. Tests were conducted to determine mechanical and durability properties up to the age of 90 days. The test results concluded that concrete made with EAF oxidizing slag and fly ash (Mix C) had greater strength and durability characteristics when compared to Mix A and Mix B. Based on the overall observations, it could be recommended that EAF oxidizing slag and fly ash could be effectively utilized as coarse aggregate replacement and cement replacement in all concrete applications. PMID:26421315
Sekaran, Alan; Palaniswamy, Murthi; Balaraju, Sivagnanaprakash
2015-01-01
Environmental and economic factors increasingly encourage higher utility of industrial by-products. The basic objective of this study was to identify alternative source for good quality aggregates which is depleting very fast due to fast pace of construction activities in India. EAF oxidizing slag as a by-product obtained during the process in steel making industry provides great opportunity to utilize it as an alternative to normally available coarse aggregates. The primary aim of this research was to evaluate the physical, mechanical, and durability properties of concrete made with EAF oxidizing slag in addition to supplementary cementing material fly ash. This study presents the experimental investigations carried out on concrete grades of M20 and M30 with three mixes: (i) Mix A, conventional concrete mix with no material substitution, (ii) Mix B, 30% replacement of cement with fly ash, and (iii) Mix C, 30% replacement of cement with fly ash and 50% replacement of coarse aggregate with EAF oxidizing slag. Tests were conducted to determine mechanical and durability properties up to the age of 90 days. The test results concluded that concrete made with EAF oxidizing slag and fly ash (Mix C) had greater strength and durability characteristics when compared to Mix A and Mix B. Based on the overall observations, it could be recommended that EAF oxidizing slag and fly ash could be effectively utilized as coarse aggregate replacement and cement replacement in all concrete applications.
Arterial versus venous lactate: a measure of sepsis in children.
Samaraweera, Sahan Asela; Gibbons, Berwyck; Gour, Anami; Sedgwick, Philip
2017-08-01
This study assessed the agreement between arterial and venous blood lactate and pH levels in children with sepsis. This retrospective, three-year study involved 60 PICU patients, with data collected from electronic or paper patient records. The inclusion criteria comprised of children (≤17 years old) with sepsis and those who had a venous blood gas taken first with an arterial blood gas taken after within one hour. The lactate and pH values measured through each method were analysed. There is close agreement between venous and arterial lactate up to 2 mmol/L. As this value increases, this agreement becomes poor. The limits of agreement (LOA) are too large (±1.90 mmol/L) to allow venous and arterial lactate to be used interchangeably. The mean difference and LOA between both methods would be much smaller if derived using lactate values under 2.0 mmol/L. There is close agreement between arterial and venous pH (MD = -0.056, LOA ± 0.121). However, due to extreme variations in pH readings during sepsis, pH alone is an inadequate marker. A venous lactate ≤2 mmol/L can be used as a surrogate for arterial lactate during early management of sepsis in children. However, if the value exceeds 2 mmol/L, an arterial sample must confirm the venous result. What is known: • In children with septic shock, a blood gas is an important test to show the presence of acidosis and high lactic acid. Hyperlactataemia on admission is an early predictor of outcome and is associated with a greater mortality risk. • An arterial sample is the standard for lactate measurement, however getting a sample may be challenging in the emergency department or a general paediatric ward. Venous samples are quicker and easier to obtain. Adult studies generally advise caution in replacing venous lactate values for the arterial standard, whilst paediatric studies are limited in this area. What is new: • This is the first study assessing the agreement between arterial and peripheral venous lactate in children with sepsis, with a significant sample of patients. • This study shows that a venous sample with a lactate of ≤ 2 mmol/L can be used as a surrogate measurement for arterial lactate during early management of sepsis in children. However, if the venous lactate is above 2 mmol/L, an arterial sample must be taken to confirm the result.
Shlebak, Abdul A; Katsarou, Alexia D; Adams, George; Fernando, Fiona
2017-02-01
Dysfibrinogenaemias may present in either congenital or acquired form and are disorders of fibrinogen structure which may or may not be associated with abnormal function. More than 100 point mutations with single amino acid substitutions have been identified in over 400 families. These lead to defective DNA in the translated fibrinogen molecule. Such cases have improved our understanding of the fibrinogen-fibrin structure. Six members of a consanguineous family including a female proband, a female sibling, three male siblings and a daughter, with ages between 29 years and 53 years presented with early onset venous and premature arterial thromboembolic disease were investigated for a pro-thrombotic tendency associated with dysfibrinogenaemia. The family was investigated using standard coagulation assays and DNA sequencing of the genes encoding the FGA, FGB and FGG. All cases have dysfibrinogenaemia with a fibrinogen level 1.4 to 1.5 (1.9-4.3 g/L). Thrombophilia testing (including AT, PS & PC, F5 G1691A (FV Leiden)/F2 (prothombin G20210A) genotypes, homocysteine, antiphosphlipid antibody, paroxysmal nocturnal haemoglobinuria by flow cytometry and Janus Kinase-2 (exon 14)) were normal. PCR amplification and sequencing of exon 2 of FBG revealed a heterozygous mutation for a c.221G> T † substitution, predicting the replacement of the native Arginine at position 74 with a Leucine (p.Arg74Leu † ). In silico analysis of p.Arg74Leu strongly support pathogenicity. A novel mutation was identified in exon 2 of FGB caused by c.221G> T † substitution, predicting the replacement of Arginine at position 74 with a Leucine (p.Arg74Leu † ) in a proband from a Kurdish family with dysfibrinogenaemia and familial venous and arterial thrombosis.
Senay, Andréa; Trottier, Milanne; Delisle, Josée; Banica, Andreea; Benoit, Benoit; Laflamme, G Yves; Malo, Michel; Nguyen, Hai; Ranger, Pierre; Fernandes, Julio C
2018-01-01
Low-molecular-weight heparin (LMWH) is a recommended anticoagulant for thromboprophylaxis after major orthopedic surgery. Dabigatran etexilate is an oral anticoagulant recognized as noninferior to LMWH. We aimed to assess the incidence of symptomatic venous thromboembolic events (VTEs) after discharge in patients who underwent joint replacement, using a hospital registry. Patients who underwent total knee and hip arthroplasty between September 2011 and March 2015 were selected. Subcutaneous enoxaparin (30 mg twice daily) was given during hospitalization. At discharge, patients received either enoxaparin 30 mg twice daily/40 mg once daily or dabigatran 220 mg/150 mg once daily. Patients were seen or called at 2, 6, and 12 weeks after surgery. Outcomes were the number of VTEs, including deep venous thrombosis, pulmonary embolism, and the number of major/minor bleeding events after discharge. After discharge, 1468 patients were prescribed enoxaparin and 904 dabigatran (1396 total knee arthroplasty and 976 total hip arthroplasty patients). Mean age was 66±10 years, and 60% were female. The cumulative incidence of VTEs during the 12-week follow-up was 0.7%. One patient sustained a VTE during the switch window. Seven patients sustained a pulmonary embolism (0.3%). There was no statistical difference between the total knee arthroplasty and total hip arthroplasty groups. The incidence of major and minor bleeding events during follow-up was 0.3% and 30.3%, respectively. These events had a higher incidence in the dabigatran group compared to the enoxaparin group after discharge ( p <0.05), but not between knee and hip replacement groups for major bleeding events. A pharmaceutical prophylaxis protocol using LMWH and dabigatran during the post-discharge period resulted in low incidences of VTE and equivalence between treatments. However, the increased number of major and minor bleeding events in patients taking dabigatran is of concern regarding the safety and needs to be evaluated using analyses adjusted for risk factors.
Changing concepts in long-term central venous access: catheter selection and cost savings.
Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A
2001-02-01
Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted central catheters were $401 per procedure, compared with $3870 for radiologically placed peripheral ports and $3532 to $4296 for surgically placed catheters. Traditional surgically placed central catheters are increasingly being replaced by peripherally inserted central venous access devices. Significant cost savings and fewer severe complications can be realized by preferential use of peripherally inserted central catheters when clinically indicated. Cost savings may not be as significant when comparing radiologically placed versus surgically placed catheters. However, significant cost savings and fewer severe complications are associated with peripheral central venous access versus the surgical or radiologic approach.
Smith, W Zachary; Harrison, Hannah B; Salhanick, Marc A; Higgins, Russell A; Ortiz, Alfonso; Olson, John D; Schwacha, Martin G; Harrison, Chantal R; Aydelotte, Jayson D; Stewart, Ronald M; Dent, Daniel L
2013-12-01
The evacuated hemothorax has been poorly described because it varies with time, it has been found to be incoagulable, and its potential effect on the coagulation cascade during autotransfusion is largely unknown. This is a prospective descriptive study of adult patients with traumatic chest injury necessitating tube thoracostomy. Pleural and venous samples were analyzed for coagulation, hematology, and electrolytes at 1 to 4 hours after drainage. Pleural samples were also analyzed for their effect on the coagulation cascade via mixing studies. Thirty-four subjects were enrolled with a traumatic hemothorax. The following measured coagulation factors were significantly depleted compared with venous blood: international normalized ratio (>9 vs 1.1) (P < .001) and activated partial thromboplastin time (aPTT) (>180 vs 24.5 seconds) (P < .001). Mixing studies showed a dose-dependent increase in coagulation dilutions through 1:8 (P < .05). An evacuated hemothorax does not vary in composition significantly with time and is incoagulable alone. Mixing studies with hemothorax plasma increased coagulation, raising safety concerns. Copyright © 2013 Elsevier Inc. All rights reserved.
Venous damage prevention by defibrotide in vinorelbine-treated patients.
Mare, M; Maisano, R; Caristi, N; Adamo, V; Altavilla, G; Carboni, R; Munaò, S; La Torre, F
2003-09-01
The aim of our study was to evaluate the incidence of venous toxicity induced by vinorelbine administration in patients who received a preventive therapy with defibrotide. From July 1996 to July 2002 we treated 203 patients with vinorelbine, 51 with vinorelbine alone and 152 with vinorelbine in combination with other drugs via peripheral vein infusion. Of the 203 patients, 123 were male and 80 female with a median age of 67 years (range 18 to 82 years), and 118 were chemotherapy-naive. Defibrotide was delivered i.v. at a dose of 400 mg in 250 ml normal saline. After infusion of 125 ml over about 15 min, vinorelbine mixed with 10 ml normal saline was delivered as quick brief repeated pulses over 5 min through the plastic tube, followed by infusion of the remaining defibrotide. The specific Rittenberg scale was used to assess venous irritation episodes. Among a total of 1336 vinorelbine infusions, with a median of five infusions per patient, the incidence of venous irritation episodes graded according to Rittenberg scale was 1.1% (15), of which 0.6% (8) were grade 2 and 0.5% (7) grade 1. Globally, 15 patients (7.3%) developed venous toxicity after a median of 3 infusions (range 1-14), but no patient had more than one event. Our findings support the use of defibrotide as an effective, safe and low-cost means for preventing vinorelbine-related venous damage.
Niimi, Yoshinari; Murata, Seiichiro; Mitou, Yumi; Ohno, Yusuke
2018-03-01
We developed a novel open cardiopulmonary bypass (CPB) system, a drainage flow servo-controlled CPB system (DS-CPB), in which rotational speed of the main roller pump is servo-controlled to generate the same amount of flow as the systemic venous drainage. It was designed to safely decrease the priming volume while maintaining a constant reservoir level, even during fluctuations of the drainage flow. We report a successful use of a novel DS-CPB system in an elderly Jehovah's Witness patient with dehydration who underwent mitral valve replacement.
Dong, Jian-Bin; Wang, Zhi-Yong; Lu, Hao; Tian, Yuan; Wang, Xin-Rui; Zhang, Zhi-Qiang
2015-03-01
To compare the efficacy of internal fixation (including PFNA and PFN) versus hip replacement (including FHR or THA) in the treatment of trochanteric fractures in adults. Reports of studies using randomized controlled trials (RCT) to compare internal fixationg with hip replacement in the management of intertrochanteric fractures were retrieved (up to January 1, 2013) from the Cochrane Library, PUBMED Data, CNKI (China National Knowledge infrastructure), Elsevier, the Chinese Biomedical Database, Wanfang Data, and manually. Methodological quality of the trials was critically assessed, and relevant data were extracted. Statistical software RevMan 5.0 was used for data-analysis. Seven articles were included in the meta-analysis. The results showed that,compared internal fixation with hip replacement,there were statistical significance in the duration of surgery time [WMD = -2.66, 95% CI (-5.25,-0.06), P = 0.05], intra-operative blood loss [WMD = -24.20, 95% CI (-30.38, -18.02), P < 0.000 01], hospital stays time [WMD = -4.72, 95% CI (-5.18, -4.25), P < 0.000 01], bearing load time [WMD = -29.54, 95% CI (-30.77, -28.31), P < 0.000 01], total complications rate [WMD = 0.15, 95% CI (0.11, 0.22), P < 0.000 01], the good rate of Harris scores [WMD = 1.09, 95% CI (0.54,1.32), P < 0.05]. However, there were no statistical significance in the rate of deep venous thrombosis [WMD = 1.09, 95% CI (0.47, 2.55), P > 0.05]. CON- CLUSION: Hip replacement (containing FHR or THA) for the treatment of intertrochanteric fractures is superior to internal fixa- tion in regards to the duration of surgery time, the mean duration of hosipital stays, mean post-operative down time, intra-opera- tive blood loss, the rate of post-operative good Harris scores. But there is not enough evidence to show any difference between hip replacement (containing THA or FHR) and internal fixation in regards to the rate of deep venous thrombosis. However, internal fixation for the treatment of intertrochanteric fractures is superior to hip replacement (containing FHR or THA) in regards to total complications rate.
A mixed-reality part-task trainer for subclavian venous access.
Robinson, Albert R; Gravenstein, Nikolaus; Cooper, Lou Ann; Lizdas, David; Luria, Isaac; Lampotang, Samsun
2014-02-01
Mixed-reality (MR) procedural simulators combine virtual and physical components and visualization software that can be used for debriefing and offer an alternative to learn subclavian central venous access (SCVA). We present a SCVA MR simulator, a part-task trainer, which can assist in the training of medical personnel. Sixty-five participants were involved in the following: (1) a simulation trial 1; (2) a teaching intervention followed by trial 2 (with the simulator's visualization software); and (3) trial 3, a final simulation assessment. The main test parameters were time to complete SCVA and the SCVA score, a composite of efficiency and safety metrics generated by the simulator's scoring algorithm. Residents and faculty completed questionnaires presimulation and postsimulation that assessed their confidence in obtaining access and learner satisfaction questions, for example, realism of the simulator. The average SCVA score was improved by 24.5 (n=65). Repeated-measures analysis of variance showed significant reductions in average time (F=31.94, P<0.0001), number of attempts (F=10.56, P<0.0001), and score (F=18.59, P<0.0001). After the teaching intervention and practice with the MR simulator, the results no longer showed a difference in performance between the faculty and residents. On a 5-point scale (5=strongly agree), participants agreed that the SCVA simulator was realistic (M=4.3) and strongly agreed that it should be used as an educational tool (M=4.9). An SCVA mixed simulator offers a realistic representation of subclavian central venous access and offers new debriefing capabilities.
New method to calculate the N2 evolution from mixed venous blood during the N2 washout.
Han, D; Jeng, D R; Cruz, J C; Flores, X F; Mallea, J M
2001-08-01
To model the normalized phase III slope (Sn) from N2 expirograms of the multibreath N2 washout is a challenge to researchers. Experimental measurements show that Sn increases with the number of breaths. Previously, we predicted Sn by setting the concentration (atm) of mixed venous blood (Fbi,N2) to a constant value of 0.3 after the fifth breath to calculate the amount of N2 transferred from the blood to the alveoli. As a consequence, the predicted curve of the Sn values showed a maximum before the quasi-steady state was reached. In this paper, we present a way of calculating the amount of N2 transferred from the blood to the alveoli by setting Fbi,N2 in the following way: In the first six breaths Fbi,N2 is kept constant at the initial value of 0.8 because circulation time needs at least 30 s to alter it. Thereafter, a single exponential function with respect the number of breaths is used: Fbi = 0.8 exp[0.112(6-n)], in which n is the breath number. The predicted Sn values were compared with experimental data from the literature. The assumption of an exponential decay in the N2 evolved from mixed venous blood is important in determining the shape of the Sn curve but new experimental data are needed to determine the validity of the model. We concluded that this new approach to calculate the N2 evolution from the blood is more meaningful physiologically.
Chen, Qi-Yu; Zhu, Xiao-Rui; Zhang, Yu
2017-01-01
The study explored hemodynamic changes in patients with cerebral arteriovenous malformations (CAVM) before and -after interventional embolization therapy with Glubran 2 acrylic glue and analyzed the related factors. CAVM patients received endovascular embolization therapy with Glubran 2. Patients' systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), blood flow velocity (BFV), and pulsatility index (PI) were measured. The location of malformed vessels, Spetzler-Martin (SM) grade, CAVM size, and type of feeding artery and venous drainage were analyzed. CAVM patients showed increased DBP, SBP, MAP, and PI and decreased average BFV compared to before therapy. CAVM patients with big CAVM size, SM grade IV/V, deep location malformed vessels, deep, and mixed venous drainage, and cortical branch and mixed artery blood-supply exhibited lower DBP, SBP, MAP, and PI but higher average BFV. Hypertensive CAVM patients showed lower DBP, SBP, MAP, average BFV, and PI before or after embolization. Hypertension, SM grade, CAVM size, malformed vessels location, venous drainage, and artery blood-supply were correlated to the hemodynamic changes of CAVM patients. Embolization with Glubran 2 acrylic glue could enhance hemodynamics in CAVM patients, and the hemodynamic changes were in correlation with the SM grade, CAVM size, and malformed vessels location. © 2017 S. Karger AG, Basel.
Hata, Taishi; Honda, Michitaka; Kobayashi, Michiya; Toyokawa, Akihiro; Tsuda, Masahiro; Tokunaga, Yukihiko; Takase, Kozo; Miyake, Masakazu; Morita, Satoshi; Nagata, Naoki; Sakamoto, Junichi; Gosho, Masahiko; Mishima, Hideyuki
2015-12-01
The aim of this phase II clinical trial was to evaluate the preventive effect of dexamethasone mixing injection for venous pain in patients with colorectal cancer during chemotherapy. Patients were randomized to receive a 2-h intravenous infusion of oxaliplatin 130 mg/m(2) on day 1 followed by capecitabine 1000 mg/m(2) (or S-1 40-60 mg/m(2)) twice daily on days 1 through 14 of every 3 weeks with or without dexamethasone 1.65 mg at the infusion on day 1. A total of 53 patients were enrolled. The analysis population consisted of 49 patients (arm A, with dexamethasone N = 24; arm B, without dexamethasone N = 25). The incidence of venous pain ≥grade 2 based on the CTCAE version 4.0 was 33.3 % in arm A and 56.0 % in arm B (relative risk 0.60; 95 % CI 0.31-1.16). The incidences based on the verbal rating scale for arms A and B were 50.0 and 64.0 %, respectively (relative risk 0.78; 95 % CI 0.48-1.28). The primary endpoint was not met in this preliminary study.
Clinical management of renal cell carcinoma with venous tumor thrombus.
Agochukwu, Nnenaya; Shuch, Brian
2014-06-01
Venous invasion is common in advanced renal cell carcinoma (RCC) due to the unique biology of this cancer. The presence of a tumor thrombus often makes clinical management challenging. In this review, we detail specific preoperative, perioperative, and surgical strategies involving the care of the complex kidney cancer patient with venous tumor involvement. We performed a comprehensive review of selected peer-reviewed publications regarding RCC tumor thrombus biology, medical and surgical management techniques, and immediate and long-term outcomes. The perioperative management may require special imaging techniques, preoperative testing, very recent imaging, and consultation with other surgical services. There are various approaches to these patients as the clinical presentation, stage of disease, primary tumor size, level of thrombus, degree of venous occlusion, presence of bland thrombus, and primary tumor laterality influence management. Select patients with metastatic disease can do well with cytoreductive nephrectomy and thrombectomy. Those with localized disease have a high risk of recurrence; however, some patients can exhibit durable survival with surgery alone. The evolving surgical and medical treatments are discussed. Even when these surgeries are performed in high volume centers, significant perioperative complications are common and greater complications are seen with higher thrombus extent. If surgery is attempted, it is important for urologic oncologists to follow strict attention to specific surgical principles. These general principles include complete vascular control, avoidance of thrombus embolization, close hemodynamic monitoring, and institutional resources for caval resection/replacement and venous bypass if necessary.
Sharma, Monika; Singh, Ashish K; Yadav, Deep N
2017-05-01
The octenyl succinyl anhydride (OSA) esterified pearl millet ( Pennisetum typhoides ) starch was evaluated as fat replacer in soft serve ice cream in comparison to other fat replacers viz. inulin, whey protein concentrate-70 and commercial starch. During temperature sweep test, the yield stress and flow behaviour index of un-pasteurized ice cream mixes increased as the temperature increased from 40 to 80 °C, while the consistency index decreased. Consistency index of aged ice cream mixes containing 2% fat replacer was higher as compared to mixes with 1% level. The aged ice cream mixes exhibited non-Newtonian behaviour as flow behaviour index values were less than one. Apparent viscosity (at 50 s -1 shear rate) of control as well as ice cream mix containing 1% OSA-esterified pearl millet starch samples was 417 and 415 mPas, respectively and did not differ significantly. The overrun of the ice cream (with 5 and 7.5% fat) containing 1 and 2% of above fat replacers ranged between 29.7 and 34.3% and was significantly lower than control (40.3%). The percent melted ice cream was also low for the ice creams containing 2% of above fat replacers at 5% fat content as compared to control. However, sensory acceptability and rheological characteristics of reduced fat ice creams containing 1.0 and 2.0% OSA-esterified pearl millet starch were at par with other fat replacers under the study. Thus, OSA-esterified pearl millet starch has potential to be used as fat replacer in reduced fat ice cream.
Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao Yue, E-mail: yuecao@umich.edu; Department of Radiology, University of Michigan, Ann Arbor, Michigan; Wang Hesheng
2013-01-01
Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation betweenmore » mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which could aid in individualizing therapy, particularly for patients at risk for liver injury after RT.« less
Miljic, D; Miljic, P; Doknic, M; Pekic, S; Stojanovic, M; Cvijovic, G; Micic, D; Popovic, V
2013-12-01
Cardiovascular morbidity in adult patients with growth hormone deficiency (GHD) and hypopituitarism is increased. Clustering of cardiovascular risk factors leading to endothelial dysfunction and impaired fibrinolysis has also been reported and may account for progression to overt vascular changes in these patients. However, effect of long lasting GH replacement therapy on fibrinolytic capacity in GH deficient patients has not been investigated so far. To investigate fibrinolysis before and after challenge with venous occlusion in GHD patients with hypopituitarism before and during one year of growth hormone replacement. Hospital based, interventional, prospective study. Twenty one patient with GHD and fourteen healthy control subjects matched for age, sex and body mass index (BMI). Anthropometric, metabolic and fibrinolytic parameters were measured at the start and after three, six and twelve months of treatment with human recombinant GH. At baseline GHD patients had significantly impaired fibrinolysis compared to healthy persons. During treatment with GH, significant changes were observed in insulin like growth factor 1(IGF-1) [from baseline 6.9(2.4-13.5) to 22.0(9.0-33.0) nmol/l after one month of treatment; p<0.01] and fibrinolysis. Improvement in fibrinolysis was mostly attributed to improvement of stimulated endothelial tissue plasminogen activator (t-PA) release in response to venous occlusion [from baseline 1.1(0.4-2.6) to 1.9(0.5-8.8) after one year of treatment; p<0.01]. Growth hormone replacement therapy has favorable effects on t-PA release from endothelium and net fibrinolytic capacity in GHD adults, which may contribute to decrease their risk of vascular complications. © 2013.
2016-01-01
The aim of this study was to examine the incidence and trends of clinically relevant venous thromboembolism (VTE) including deep vein thrombosis (DVT) and pulmonary embolism (PE) after hip and knee replacement arthroplasty (HKRA) in Korea. Between January 1 and December 31, 2010, 22,127 hip replacement arthroplasty (HRA) patients and 52,882 knee replacement arthroplasty (KRA) patients were enrolled in the analysis using the administrative claims database of the Health Insurance Review and Assessment Service (HIRA). All available parameters including procedure history and clinically relevant VTE during the 90 days after HKRA were identified based on diagnostic and electronic data interchange (EDI) codes. The overall incidence of VTE, DVT, and PE during the 90 days was 3.9% (n=853), 2.7% (n=597), and 1.5% (n=327) after HRA, while the incidence was 3.8% (n=1,990), 3.2% (n=1,699), and 0.7% (n=355) after KRA. The incidence of VTE after HKRA was significantly higher in patients who had previous VTE history (odds ratio [OR], 10.8 after HRA, OR, 8.5 after KRA), chronic heart failure (2.1, 1.3), arrhythmia (1.8, 1.7), and atrial fibrillation (3.4, 2.1) than in patients who did not. The VTE incidence in patients with chemoprophylaxis was higher than that in patients without chemoprophylaxis. The incidence of VTEs revealed in this retrospective review was not low compared with the results of the studies targeting other Asian or Caucasian populations. It may warrant routine prevention including employment of chemoprophylaxis. However, the limitation of the reviewed data mandates large scale prospective investigation to affirm this observation. PMID:26770042
Lassen, M R; Fisher, W; Mouret, P; Agnelli, G; George, D; Kakkar, A; Mismetti, P; Turpie, A G G
2012-05-01
Semuloparin is a novel ultra-low-molecular-weight heparin under development for venous thromboembolism (VTE) prevention in patients at increased risk, such as surgical and cancer patients. Three Phase III studies compared semuloparin and enoxaparin after major orthopedic surgery: elective knee replacement (SAVE-KNEE), elective hip replacement (SAVE-HIP1) and hip fracture surgery (SAVE-HIP2). All studies were multinational, randomized and double-blind. Semuloparin and enoxaparin were administered for 7-10 days after surgery. Mandatory bilateral venography was to be performed between days 7 and 11. The primary efficacy endpoint was a composite of any deep vein thrombosis, non-fatal pulmonary embolism or all-cause death. Safety outcomes included major bleeding, clinically relevant non-major (CRNM) bleeding, and any clinically relevant bleeding (major bleeding plus CRNM). In total, 1150, 2326 and 1003 patients were randomized in SAVE-KNEE, SAVE-HIP1 and SAVE-HIP2, respectively. In all studies, the incidences of the primary efficacy endpoint were numerically lower in the semuloparin group vs. the enoxaparin group, but the difference was statistically significant only in SAVE-HIP1. In SAVE-HIP1, clinically relevant bleeding and major bleeding were significantly lower in the semuloparin vs. the enoxaparin group. In SAVE-KNEE and SAVE-HIP2, clinically relevant bleeding tended to be higher in the semuloparin group, but rates of major bleeding were similar in the two groups. Other safety parameters were generally similar between treatment groups. Semuloparin was superior to enoxaparin for VTE prevention after hip replacement surgery, but failed to demonstrate superiority after knee replacement surgery and hip fracture surgery. Semuloparin and enoxaparin exhibited generally similar safety profiles. © 2012 International Society on Thrombosis and Haemostasis.
Brain, Matthew J; Roodenburg, Owen S; McNeil, John
2017-01-01
It is widespread practice during citrate anticoagulated renal replacement therapy to monitor circuit ionised calcium (iCa2+) to evaluate the effectiveness of anticoagulation. Whether the optimal site to sample the blood path is before or after the haemofilter is a common question. Using a prospectively collected observational dataset from intensive care patients receiving pre-dilution continuous veno-venous haemodiafiltration (CVVHD-F) with integrated citrate anticoagulation we compared paired samples of pre and post filter iCa2+ where the target range was 0.3-0.5 mmol.L-1 as well as concurrently collected arterial iCa2+. Two nested mixed methods linear models were fitted to the data describing post vs pre filter iCa2+, and the relationship of pre, post and arterial samples. An 11 bed general intensive care unit. 450 grouped samples from 152 time periods in seven patients on CRRT with citrate anticoagulation. The relationship of post to pre-filter iCa2+ was not 1:1 with post = 0.082 + 0.751 x pre-filter iCa2+ (95% CI intercept: 0.015-0.152, slope 0.558-0.942). Variation was greatest between patients rather than between circuits within the same patient or citrate dose. Compared to arterial iCa2+ there was no significant difference between pre and post-filter sampling sites (F-value 0.047, p = 0.827). These results demonstrate that there is minimal difference between pre and post filter samples for iCa2+ monitoring of circuit anticoagulation in citrate patients relative to the arterial iCa2+ in CVVHD-F however compared to pre-filter sampling, post filter sampling has a flatter response and greater variation.
Roodenburg, Owen S.; McNeil, John
2017-01-01
Background It is widespread practice during citrate anticoagulated renal replacement therapy to monitor circuit ionised calcium (iCa2+) to evaluate the effectiveness of anticoagulation. Whether the optimal site to sample the blood path is before or after the haemofilter is a common question. Methods Using a prospectively collected observational dataset from intensive care patients receiving pre-dilution continuous veno-venous haemodiafiltration (CVVHD-F) with integrated citrate anticoagulation we compared paired samples of pre and post filter iCa2+ where the target range was 0.3–0.5 mmol.L-1 as well as concurrently collected arterial iCa2+. Two nested mixed methods linear models were fitted to the data describing post vs pre filter iCa2+, and the relationship of pre, post and arterial samples. Setting An 11 bed general intensive care unit. Participants 450 grouped samples from 152 time periods in seven patients on CRRT with citrate anticoagulation. Results The relationship of post to pre-filter iCa2+ was not 1:1 with post = 0.082 + 0.751 x pre-filter iCa2+ (95% CI intercept: 0.015–0.152, slope 0.558–0.942). Variation was greatest between patients rather than between circuits within the same patient or citrate dose. Compared to arterial iCa2+ there was no significant difference between pre and post-filter sampling sites (F-value 0.047, p = 0.827) Conclusion These results demonstrate that there is minimal difference between pre and post filter samples for iCa2+ monitoring of circuit anticoagulation in citrate patients relative to the arterial iCa2+ in CVVHD-F however compared to pre-filter sampling, post filter sampling has a flatter response and greater variation. PMID:29272278
Aboud, Anas; Mederos-Dahms, Hendrikje; Liebing, Kai; Zittermann, Armin; Schubert, Harald; Murray, Edward; Renner, Andre; Gummert, Jan; Börgermann, Jochen
2015-05-29
Because of its low rate of clinical complications, miniaturized extracorporeal perfusion systems (MEPS) are frequently used in heart centers worldwide. However, many recent studies refer to the higher probability of gaseous microemboli formation by MEPS, caused by subzero pressure values. This is the main reason why various de-airing devices were developed for today's perfusion systems. In the present study, we investigated the potential benefits of a simple one-way-valve connected to a volume replacement reservoir (OVR) for volume and pressure compensation. In an experimental study on 26 pigs, we compared MEPS (n = 13) with MEPS plus OVR (n = 13). Except OVR, perfusion equipment was identical in both groups. Primary endpoints were pressure values in the venous line and the right atrium as well as the number and volume of air bubbles. Secondary endpoints were biochemical parameters of systemic inflammatory response, ischemia, hemodilution and hemolysis. One animal was lost in the MEPS + OVR group. In the MEPS + OVR group no pressure values below -150 mmHg in the venous line and no values under -100 mmHg in right atrium were noticed. On the contrary, nearly 20% of venous pressure values in the MEPS group were below -150 and approximately 10% of right atrial pressure values were below -100 mmHg. Compared with the MEPS group, the bubble counter device showed lower numbers of arterial air bubbles in the MEPS + OVR group (mean ± SD: 13444 ± 5709 vs. 1 ± 2, respectively; p < 0.001). In addition, bubble volume was significantly lower in the MEPS + OVR group than in the MEPS group (mean ± SD: 1522 ± 654 μl vs. 4 ± 6 μl, respectively; p < 0.001). The proinflammatory cytokine interleukin-6 and biochemical indices of cardiac ischemia (creatine kinase, and troponin I) were comparable between both groups. The use of a miniaturized perfusion system with a volume replacement reservoir is able to counteract excessive negative venous line pressures and to reduce the number and volume of arterial air bubbles. This approach may lead to a lower rate of neurological complications.
Højen, A A; Sørensen, E E; Dreyer, P S; Søgaard, M; Larsen, T B
2017-12-01
Essentials Long-term mental wellbeing of adolescents and young adults with venous thromboembolism is unclear. This multistage mixed methods study was based on Danish nationwide registry data and interviews. Mental wellbeing is negatively impacted in the long-term and uncertainty of recurrence is pivotal. The perceived health threat is more important than disease severity for long-term mental wellbeing. Background Critical and chronic illness in youth can lead to impaired mental wellbeing. Venous thromboembolism (VTE) is a potentially traumatic and life-threatening condition. Nonetheless, the long-term mental wellbeing of adolescents and young adults (AYAS) with VTE is unclear. Objectives To investigate the long-term mental wellbeing of AYAS (aged 13-33 years) diagnosed with VTE. Methods We performed a multistage mixed method study based on data from the Danish nationwide health registries, and semistructured interviews with 12 AYAS diagnosed with VTE. An integrated mixed methods interpretation of the findings was conducted through narrative weaving and joint displays. Results The integrated mixed methods interpretation showed that the mental wellbeing of AYAS with VTE had a chronic perspective, with a persistently higher risk of psychotropic drug purchase among AYAS with a first-time diagnosis of VTE than among sex-matched and age-matched population controls and AYAS with a first-time diagnosis of insulin-dependent diabetes mellitus. Impaired mental wellbeing was largely connected to a fear of recurrence and concomitant uncertainty. Therefore, it was important for the long-term mental wellbeing to navigate uncertainty. The perceived health threat played a more profound role in long-term mental wellbeing than disease severity, as the potential life threat was the pivot which pointed back to the initial VTE and forward to the perception of future health threat and the potential risk of dying of a recurrent event. Conclusion Our findings show that the long-term mental wellbeing of AYAS diagnosed with VTE is negatively affected, and highlights these patients' need for adequate support. © 2017 International Society on Thrombosis and Haemostasis.
Ylönen, Minna; Viljamaa, Jaakko; Isoaho, Hannu; Junttila, Kristiina; Leino-Kilpi, Helena; Suhonen, Riitta
2017-11-01
To test the effectiveness of an Internet-based education programme about venous leg ulcer nursing care on perceived and theoretical knowledge levels and attitudes among nurses working in home health care. Nurses have been shown to have knowledge gaps in venous leg ulcer nursing care. Internet-based learning could offer a means for flexible continuing education for home healthcare environment. Quasi-experimental study with pre- and postmeasurements and nonequivalent intervention and comparison groups. Nurses (n = 946) in home health care in two Finnish municipalities were invited to participate in the study and divided into intervention and comparison groups. The intervention group received education programme about venous leg ulcer nursing care, while the comparison group did not. Data were collected at baseline, at six weeks and at 10 weeks to test the hypotheses: nurses using education programme about venous leg ulcer nursing care will have higher level of knowledge and more positive attitudes than those not using education programme about venous leg ulcer nursing care. An analysis of variance and mixed models with repeated measures were used to test differences in knowledge and attitudes between and within the groups. There were statistically significant increases in knowledge levels in the intervention group from baseline to the first and second follow-up measurements. In the comparison group, the knowledge levels remained unchanged during the study. Attitude levels remained unchanged in both groups. Nurses' perceived and theoretical knowledge levels of venous leg ulcer nursing care can be increased with Internet-based education. However, this increase in knowledge levels is short-lived, which emphasises the need for continuous education. Internet-based education about venous leg ulcer nursing care is recommended for home healthcare nurses. Education programme about venous leg ulcer nursing care provides flexible method for nurses' learning with feasible and cost-effective access to evidence-based education. Education programme about venous leg ulcer nursing care material can be used in all nursing environments where Internet is available. © 2017 John Wiley & Sons Ltd.
Pérez-Granda, María Jesús; Guembe, María; Cruces, Raquel; Barrio, José María; Bouza, Emilio
2016-02-02
Culture of catheter hubs and skin surrounding the catheter entry site has a negative predictive value for catheter tip colonization. However, manipulation of the hub for culture requires the hubs to be swabbed, introducing potential dislodging of biofilm and subsequent migration of microorganisms. Hubs are usually closed with needleless connectors (NCs), which are replaced regularly. Our objective was to evaluate whether culture of flushed withdrawn NCs is an alternative to hub culture when investigating central venous catheter colonization. The study population comprised 49 intensive care unit patients whose central venous catheters had been in place for at least 7 days. Cultures of NCs and skin were obtained weekly. We included 82 catheters with more than 7 days' indwelling time. The catheter tip colonization rate was 18.3% (15/82). Analysis of skin and NC cultures revealed a 92.5% negative predictive value for catheter colonization. Three episodes of catheter-related bloodstream infection (C-RBSI) occurred in patients with colonized catheters. Surveillance of NC and skin cultures could help to identify patients at risk for C-RBSI.
Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei
2004-08-01
A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.
Kelechi, Teresa J; Mueller, Martina; Zapka, Jane G; King, Dana E
2011-11-01
The aim of this randomized clinical trial was to investigate a cryotherapy (cooling) gel wrap applied to lower leg skin affected by chronic venous disorders to determine whether therapeutic cooling improves skin microcirculation. Chronic venous disorders are under-recognized vascular health problems that result in severe skin damage and ulcerations of the lower legs. Impaired skin microcirculation contributes to venous leg ulcer development, thus new prevention therapies should address the microcirculation to prevent venous leg ulcers. Sixty participants (n = 30 per group) were randomized to receive one of two daily 30-minute interventions for four weeks. The treatment group applied the cryotherapy gel wrap around the affected lower leg skin, or compression and elevated the legs on a special pillow each evening at bedtime. The standard care group wore compression and elevated the legs only. Laboratory pre- and post-measures included microcirculation measures of skin temperature with a thermistor, blood flow with a laser Doppler flowmeter, and venous refill time with a photoplethysmograph. Data were collected between 2008 2009 and analysed using descriptive statistics, paired t-tests or Wilcoxon signed ranks tests, logistic regression analyses, and mixed model analyses. Fifty-seven participants (treatment = 28; standard care = 29) completed the study. The mean age was 62 years, 70% female, 50% African American. In the final adjusted model, there was a statistically significant decrease in blood flow between the two groups (-6.2[-11.8; -0.6], P = 0.03). No statistically significant differences were noted in temperature or venous refill time. Study findings suggest that cryotherapy improves blood flow by slowing movement within the microcirculation and thus might potentially provide a therapeutic benefit to prevent leg ulcers. © 2011 Blackwell Publishing Ltd.
Cheung, Alfred K; Imrey, Peter B; Alpers, Charles E; Robbin, Michelle L; Radeva, Milena; Larive, Brett; Shiu, Yan-Ting; Allon, Michael; Dember, Laura M; Greene, Tom; Himmelfarb, Jonathan; Roy-Chaudhury, Prabir; Terry, Christi M; Vazquez, Miguel A; Kusek, John W; Feldman, Harold I
2017-10-01
Intimal hyperplasia and stenosis are often cited as causes of arteriovenous fistula maturation failure, but definitive evidence is lacking. We examined the associations among preexisting venous intimal hyperplasia, fistula venous stenosis after creation, and clinical maturation failure. The Hemodialysis Fistula Maturation Study prospectively observed 602 men and women through arteriovenous fistula creation surgery and their postoperative course. A segment of the vein used to create the fistula was collected intraoperatively for histomorphometric examination. On ultrasounds performed 1 day and 2 and 6 weeks after fistula creation, we assessed fistula venous stenosis using pre-specified criteria on the basis of ratios of luminal diameters and peak blood flow velocities at certain locations along the vessel. We determined fistula clinical maturation using criteria for usability during dialysis. Preexisting venous intimal hyperplasia, expressed per 10% increase in a hyperplasia index (range of 0%-100%), modestly associated with lower fistula blood flow rate (relative change, -2.5%; 95% confidence interval [95% CI], -4.6% to -0.4%; P =0.02) at 6 weeks but did not significantly associate with stenosis (odds ratio [OR], 1.07; 95% CI, 1.00 to 1.16; P =0.07) at 6 weeks or failure to mature clinically without procedural assistance (OR, 1.07; 95% CI, 0.99 to 1.15; P =0.07). Fistula venous stenosis at 6 weeks associated with maturation failure (OR, 1.98; 95% CI, 1.25 to 3.12; P =0.004) after controlling for case mix factors, dialysis status, and fistula location. These findings suggest that postoperative fistula venous stenosis associates with fistula maturation failure. Preoperative venous hyperplasia may associate with maturation failure but if so, only modestly. Copyright © 2017 by the American Society of Nephrology.
Rheological properties of ice cream mixes and frozen ice creams containing fat and fat replacers.
Adapa, S; Dingeldein, H; Schmidt, K A; Herald, T J
2000-10-01
Ice cream mixes and frozen ice creams at milk fat levels of 12%, 8%, 6%, 6% plus a protein-based fat replacer, and 6% plus a carbohydrate-based fat replacer were evaluated for viscoelastic properties by dynamic testing with sinusoidal oscillatory tests at various frequencies. The storage modulus (G'), loss modulus (G"), and tan delta (G"/G') were calculated for all the treatments to determine changes in the viscous and elastic properties of the mixes and frozen ice creams due to fat content. In ice cream mixes, G' and G" exhibited a strong frequency dependence. The G" was higher than G' throughout the frequency range (1 to 8 Hz) examined, without any crossover, except for the 12% mix. Elastic properties of the ice cream mixes decreased as fat content decreased. Tan delta values indicated that fat replacers did not enhance the elastic properties of the ice cream mixes. In all frozen ice creams, G' and G" again showed a frequency dependence throughout the range tested (0.5 to 10 Hz). The amount of fat in ice creams and the degree of fat destabilization affected the elasticity in the frozen product. Even though the ice creams did not have significant elastic properties, when compared as a group the samples with higher fat content had higher elastic properties. The addition of protein-based and carbohydrate-based fat replacers did not enhance the elastic properties of the ice creams but did increase the viscous properties.
Rheumatic mitral valve stenosis mimicking advanced lung cancer.
von Lueder, Thomas; Steine, Kjetil; Nerdrum, Tone; Steen, Torkel; Bay, Dag; Humerfelt, Sjur; Atar, Dan
2007-09-01
This report describes a patient with a perihilar mass and mediastinal lymphadenopathy mimicking advanced lung cancer. The patient, a 45-year old regular smoker, was admitted to hospital for dyspnea and tachyarrhythmia, and during hospitalization he was diagnosed with severe rheumatic mitral valve stenosis (MVS) and aortic regurgitation as well as pulmonary venous hypertension. Surgical valve replacement and removal of an atrial thrombus was delayed considerably by diagnostic work-up for suspected malignancy. After cardiac surgery had been performed, recovery was uneventful. On follow-up 1 year later, echocardiography showed well-functioning prosthetic mitral and aortic valves, and normal findings on chest X-ray. Perihilar masses and mediastinal lymphadenopathy presented in this case constitute infrequent yet established findings in MVS, resulting from pulmonary venous congestion and hypertension, and focal lymphedema.
Combined oral contraceptives: venous thrombosis.
de Bastos, Marcos; Stegeman, Bernardine H; Rosendaal, Frits R; Van Hylckama Vlieg, Astrid; Helmerhorst, Frans M; Stijnen, Theo; Dekkers, Olaf M
2014-03-03
Combined oral contraceptive (COC) use has been associated with venous thrombosis (VT) (i.e., deep venous thrombosis and pulmonary embolism). The VT risk has been evaluated for many estrogen doses and progestagen types contained in COC but no comprehensive comparison involving commonly used COC is available. To provide a comprehensive overview of the risk of venous thrombosis in women using different combined oral contraceptives. Electronic databases (Pubmed, Embase, Web of Science, Cochrane, CINAHL, Academic Search Premier and ScienceDirect) were searched in 22 April 2013 for eligible studies, without language restrictions. We selected studies including healthy women taking COC with VT as outcome. The primary outcome of interest was a fatal or non-fatal first event of venous thrombosis with the main focus on deep venous thrombosis or pulmonary embolism. Publications with at least 10 events in total were eligible. The network meta-analysis was performed using an extension of frequentist random effects models for mixed multiple treatment comparisons. Unadjusted relative risks with 95% confidence intervals were reported.Two independent reviewers extracted data from selected studies. 3110 publications were retrieved through a search strategy; 25 publications reporting on 26 studies were included. Incidence of venous thrombosis in non-users from two included cohorts was 0.19 and 0.37 per 1 000 person years, in line with previously reported incidences of 0,16 per 1 000 person years. Use of combined oral contraceptives increased the risk of venous thrombosis compared with non-use (relative risk 3.5, 95% confidence interval 2.9 to 4.3). The relative risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate, or drospirenone were similar and about 50-80% higher than for combined oral contraceptives with levonorgestrel. A dose related effect of ethinylestradiol was observed for gestodene, desogestrel, and levonorgestrel, with higher doses being associated with higher thrombosis risk. All combined oral contraceptives investigated in this analysis were associated with an increased risk of venous thrombosis. The effect size depended both on the progestogen used and the dose of ethinylestradiol. Risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate and drospirenone were similar, and about 50-80% higher than with levonorgestrel. The combined oral contraceptive with the lowest possible dose of ethinylestradiol and good compliance should be prescribed-that is, 30 μg ethinylestradiol with levonorgestrel.
Fernández, Mónica; Calvo-Alén, Jaime; Bertoli, Ana M; Bastian, Holly M; Fessler, Barri J; McGwin, Gerald; Reveille, John D; Vilá, Luis M; Alarcón, Graciela S
2007-10-01
To examine the influence of hormone replacement therapy (HRT) in the occurrence of vascular arterial and venous thrombotic events in postmenopausal women with systemic lupus erythematosus (SLE). SLE women aged > or =16 years, disease duration < or =5 years from LUMINA, a multiethnic, longitudinal outcome study, were included. Menopause was defined at disease onset as the presence of amenorrhea >6 months and/or oophorectomy, and/or increased follicle stimulating hormone values, and/or HRT use regardless of the presence or absence of climacteric symptoms (hot flashes). Patients were divided into HRT ever users and nonusers. Patients with positive antiphospholipid antibodies (n = 9) or vascular arterial events (n = 1) occurring before HRT use were excluded. The occurrence of vascular arterial and venous thrombotic events was compared between HRT users and HRT nonusers and its role examined by logistic regression after adjusting for "confounding by indication" using propensity score or logistic regression analyses. Seventy-two postmenopausal women, 32 (44%) HRT users and 40 (56%) HRT nonusers, were studied. HRT use was associated with fewer vascular arterial but not venous thrombotic events (P = 0.021) in the univariable analyses. However, after adjusting for the propensity score, HRT use was no longer significant (P = 0.064). Comparable results were obtained by logistic regression. HRT use was not associated with the occurrence of vascular arterial events in the LUMINA patients. HRT use in women with SLE should be individualized, but our data suggest its use may be safe if antiphospholipid antibodies are not present or vascular arterial events have not previously occurred.
Significance of coupling device for vessel anastomosis in esophageal reconstruction.
Watanabe, Y; Horiuchi, A; Yamamoto, Y; Kikkawa, H; Kusunose, H; Sugishita, H; Sato, K; Yoshida, M; Yukumi, S; Kawachi, K
2005-01-01
To prevent an anastomotic failure due to impaired blood supply, several trials have been performed such as preoperative ischemic conditioning by transarterial embolization of the left gastric, right gastric and splenic arteries or microvascular anastomosis. We assess the significance of an automatic anastomotic coupling device for vessel anastomosis, which we have continuously utilized, to simplify the task and shorten the anastomotic time since March 1999. 8 patients who underwent venous anastomosis by an automatic anastomotic coupling device were evaluated for the time of anastomosis, total ischemic time and outcomes. Venous anastomosis was completed within 5 minutes on average. Microscopic arterial anastomosis by hand took 35 minutes on average. For gastric tube reconstruction, venous anastomosis by an automatic coupling device took only 5 minutes. The top of the gastric tube showed congestion before venous anastomosis, but rapidly recovered from it after anastomosis. Postoperative endoscopic observation of the mucosal color of the replaced intestine or gastric tube was started 3 days after surgery and revealed no ischemia or congestion. The postoperative course was uneventful except one case suffering from pneumonia but leakage was not observed in any case. An automatic anastomotic coupling device can perform an easy and reliable vascular anastomosis for patients who undergo esophageal reconstruction. The device may shorten the operating time and consequently the ischemic time of the gastric tube or jejunal or colonic graft, which in turn may lead to a decrease of complications.
Wu, Yunzhen; Wang, Chunting
2015-05-01
To establish a mathematical formula for choosing the manner of replacement fluid infusion in continuous renal replacement therapy (CRRT), so as to provide the basis for improving the treatment effect. A mathematical formula for choosing the manner of replacement fluid infusion with continuous veno-venous hemofiltration (CVVH) was taken as an example, and it was compared with the result of standard replacement fluid in order to analyze the effect of different manners of infusion. (1) Comparison parameters: the plasma volume ("Vreturn") and some electrolyte concentration ("Creturn") in back way of CRRT ( if other thing was solute, filter coefficient should be 1.0). (2) Research objects: the actual replacement fluid (for example, the most complex should be sorted into A and B type) mode (pre or post) was compared with the standard replacement fluid (the A and B in one). (3) Based on the formula of standard replacement, four equations in different conditions were derived: pre-dilution and post-dilution mode; same direction and same ratio; same direction and different ratio; different direction and same ratio; different direction and different ratio. The calculated results of "Vreturn" (except hematocrit) and "Creturn" were same to the standard only following the rule of same direction and ratio for A and B no matter pre-dilution mode or post-dilution mode, and it was different from the standard in others. In pre-dilution mode and post-dilution mode, it showed: (1) A and B in same direction and different ratio: "Vreturn" and "Creturn" were different from the standard for the alterative ratio of B. (2) A and B in different direction and same ratio: "Vreturn" was same to the standard, but "Creturn" was different from the standard for the completely different and more complex computational formula. (3) A and B in different direction and different ratio: both "Vreturn" and "Creturn" were different from the standard. The different "Vreturn" was due to the different ratio of B. The different "Creturn" was caused by different ratio of B and the completely different computational formula. (1) For parts of replacement fluid which must be separated (for example, bicarbonate formula), the result is same to the standard, and is predicted and mastered only following the rule of same direction and ratio. Otherwise, we need to calculate the two parameters over and over again. The result will run out of our judgment. The wrongness of losing water and electrolyte disorders maybe come out. (2) Accordingly,the formula could be used to analyze the same case like the separated replacement infusion, for example, a large number of citrates as regional anticoagulation were infused only in the front of filter, while the replacement fluid can be done in varied forms.
Constitutive modeling of jugular vein-derived venous valve leaflet tissues.
Kaul, Nayyan; Huang, Hsiao-Ying Shadow
2017-11-01
Venous valve tissues, though used in vein reconstruction surgeries and bioprosthetic valves with moderate success, have not been extensively studied with respect to their structure. Their inherent anisotropic, non-linear behavior combined with severe diseases which affect veins, such as chronic venous insufficiency, warrant understanding the structure and material behavior of these tissues. Hence, before any bioprosthetic grafts may be used in place of tissues, it is of the utmost importance to understand the mechanical and structural properties of these tissues as this may lead to higher success rates for valve replacement surgeries. The longevity of the bioprosthetics may also increase if the manufactured grafts behave the same as native valves. Building on the scant information about the uniaxial and biaxial mechanical properties of jugular venous valves and wall tissues from previous studies, the current focus of our investigation lies in understanding the material behavior by establishing a phenomenological strain energy-based constitutive relation for the tissues. We used bovine veins to study the behavior of valve leaflet tissue and adjoining wall tissue (from the proximal and distal ends of the veins) under different biaxial testing protocols. We looked at the behavior of numerical partial derivatives of the strain energy to select a suitable functional form for the strain energy for wall and valve tissues. Using this strain energy descriptor, we determined the Cauchy stress and compared it with experimental results under additional sets of displacement-controlled biaxial testing protocols to find material specific model parameters by the Powell's method algorithm. Results show that whereas wall tissue strain energy can be explained using a polynomial non-linear function, the valve tissue, due to higher non-linearities, requires an exponential function. This study may provide useful information for the primary stages of bioprosthetic designs and replacement surgeries and may support future studies investigating structural models. It may also support the study of valvular diseases by providing a way to understand material properties and behavior and to form a continuum model when required for numerical analyses and computational simulations. Copyright © 2017 Elsevier Ltd. All rights reserved.
B.M. Collins; S.L. Stephens
2010-01-01
The complexity inherent in variable, or mixed-severity fire regimes makes quantitative characterization of important fire regime attributes (e.g., proportion of landscape burned at different severities, size and distribution of stand-replacing patches) difficult. As a result, there is ambiguity associated with the term ‘mixed-severity’. We address...
Evaluation of FloSeal as a Potential Intracavitary Hemostatic Agent
2006-02-01
Laws ER Jr. Use of FloSeal hemostatic sealant in transsphenoidal pituitary surgery : technical note. Neurosurgery. 2002;51:513–516. 14. Kheirabadi BS...of death in com- bat and civilian trauma. When surgery is unavailable, one potential solution to such hemorrhage might be the introduction of an agent...situations, including venous and arterial vascular surgery ,7,9 cardiac valve replacement or cardiopulmonary bypass grafting,6 partial nephrectomies,10
Leibundgut, Gregor; Bernheim, Alain M
2010-04-01
The authors report the case of a 77-year-old male patient with sinus rhythm and a first-degree atrioventricular (AV) block who was referred for echocardiographic follow-up 18 years after aortic valve replacement. Left ventricular systolic function as well as the function of the aortic prosthesis was normal. Systolic mitral regurgitation (MR) was virtually absent, but isolated late diastolic MR was detected by colour Doppler imaging. Coincidental to the occurrence of diastolic MR, a second late diastolic forward flow in the pulmonary veins was observed. Therefore, during the prolonged left atrial relaxation caused by first-degree AV block, the left atrial pressure drops below the pressure in both adjacent chambers in late diastole, resulting in both late diastolic MR and a second diastolic pulmonary venous forward flow.
Mixed venous oxygen saturation monitoring revisited: thoughts for critical care nursing practice.
Christensen, Martin
2012-05-01
Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO(2)). The aim of this paper is to put forward the notion that SvO(2) provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO(2). SvO(2) monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO(2) monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO(2)) might be an attractive alternative to SvO(2) because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO(2) is less accurate than SvO(2) and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO(2) and SvO(2) and this is dependent on the presenting disease, in some cases SvO(2) will be significantly lower than ScvO(2). Whilst newer technologies have been developed to continuously measure cardiac output, SvO(2) monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO(2) or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO(2), trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO(2) will be approximately 16% lower. Copyright © 2011 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Lee, Jong-Myung; Jung, Shin; Moon, Kyung-Sub; Seo, Jeong-Jin; Kim, In-Young; Jung, Tae-Young; Lee, Jung-Kil; Kang, Sam-Suk
2005-08-01
Recent developments in magnetic resonance (MR) technology now enable the use of MR venography, providing 3-dimensional (3D) images of intracranial venous structures. The purpose of this study was to assess the usefulness of 3D contrast-enhanced MR venography (CE MRV) in the evaluation of intracranial venous system for surgical planning of brain tumors. Forty patients underwent 3D CE MRV, as well as 25 patients, 2-dimensional (2D) time-of-flight (TOF) MR venography in axial and sagittal planes; and 10 patients, digital subtraction angiography. We determined the number of visualized sinuses and cortical veins. Degree of visualization of the intracranial venous system on 3D CE MRV was compared with that of 2D TOF MR venography and digital subtraction angiography as a standard. We also assessed the value of 3D CE MRV in the investigation of sinus occlusion or localization of cortical draining veins preoperatively. Superficial cortical veins and the dural sinus were better visualized on 3D CE MRV than on 2D TOF MR venography. Both MR venographic techniques visualized superior sagittal sinus, lateral sinus, sigmoid sinus, straight sinus, and internal cerebral vein and provided more detailed information by showing obstructed sinuses in brain tumors. Only 3D CE MRV showed superficial cortical draining veins. However, it was difficult to accurately evaluate the presence of cortical collateral venous drainage. Although we do not yet advocate MR venography to replace conventional angiography as the imaging standard for brain tumors, 3D CE MRV can be regarded as a valuable diagnostic method just in evaluating the status of major sinuses and localization of the cortical draining veins.
Development and testing of an artificial arterial and venous pulse oximeter.
Cloete, G; Fourie, P R; Scheffer, C
2013-01-01
The monitoring of patients healthcare is of a prime importance to ensure their efficient and effective treatment. Monitoring blood oxygen saturation is a field which has grown significantly in recent times and more specifically in tissues affected by diseases or conditions that may negatively affect the function of the tissue. This study involved the development and testing of a highly sensitive non-invasive blood oxygen saturation monitoring device. A device that can be used to continuously monitor the condition of tissue affected by diseases which affect the blood flow through the tissue, and the oxygen usage in tissue. The device's system was designed to specifically monitor occluded tissue which has low oxygen saturations and low perfusion. Although with limitted validation the system was unable to accurately measure the venous oxygenation specifically, but it was able to measure the mixed oxygen saturation. With further research it would be possible to validate the system for measuring both the arterial and venous oxygen saturations.
Shahbazov, Rauf; Fox, Michael; Alejo, Jennifer L; Anjum, Malik A; Azari, Feredun; Doyle, Alden; Agarwal, Avinash; Brayman, Kenneth L
2018-04-01
Rhabdomyolysis is characterized by muscle cell death which can result in acute kidney injury from pigment nephropathy. We present a patient who developed rhabdomyolysis immediately after deceased donor kidney transplantation surgery and was managed with continuous renal replacement therapy that resulted in successful salvage of the kidney allograft. Patients who develop acute kidney failure requiring renal replacement therapy generally have a poor prognosis. It is worth noting that while continuous veno-venous hemofiltration (CVVHF) offers greater volume support and continuous clearance compared to hemodialysis (HD), recent studies have demonstrated no clinically significant improvement in clinical outcome between the two. Perhaps CVVHF is a better modality compared to HD in this setting to prevent further insult from pigment nephropathy to an allograft. A combination of early diagnosis and intensive continuous renal replacement therapy can be used for allograft salvage in a patient with rhabdomyolysis in the immediate post-kidney transplant period.
Mueller, Martina; Zapka, Jane G.; King, Dana E.
2011-01-01
Aim This randomized clinical trial was conducted 2008 – 2009 to investigate a cryotherapy (cooling) gel wrap applied to lower leg skin affected by chronic venous disorders to determine whether therapeutic cooling improves skin microcirculation. Impaired skin microcirculation contributes to venous leg ulcer development, thus new prevention therapies should address the microcirculation to prevent venous leg ulcers. Data Sources Sixty participants (n = 30 per group) were randomized to receive one of two daily 30-minute interventions for four weeks. The treatment group applied the cryotherapy gel wrap around the affected lower leg skin, or compression and elevated the legs on a special pillow each evening at bedtime. The standard care group wore compression and elevated the legs only. Laboratory pre- and post-measures included microcirculation measures of skin temperature with a thermistor, blood flow with a laser Doppler flowmeter, and venous refill time with a photoplethysmograph. Review methods Data were analysed using descriptive statistics, paired t-tests or Wilcoxon signed ranks tests, logistic regression analyses, and mixed model analyses. Results Fifty-seven participants (treatment = 28; standard care = 29) completed the study. The mean age was 62 years, 70% female, 50% African American. In the final adjusted model, there was a statistically significant decrease in blood flow between the two groups (−6.2[−11.8; −0.6], P = 0.03). No statistically significant differences were noted in temperature or venous refill time. Conclusion Study findings suggest that cryotherapy improves blood flow by slowing movement within the microcirculation and thus might potentially provide a therapeutic benefit to prevent leg ulcers. PMID:21592186
Venous access and care: harnessing pragmatics in harm reduction for people who inject drugs.
Harris, Magdalena; Rhodes, Tim
2012-06-01
To explore the facilitators of long-term hepatitis C avoidance among people who inject drugs. We employed a qualitative life history design. Recruitment took place through low-threshold drug services and drug user networks in South East and North London. Participants were interviewed at the recruitment services or in their homes. The sample comprised 35 people who inject drugs, 20 of whom were hepatitis C antibody-negative. Participants' average injecting trajectory was 19 years (6-33), with 66% primarily injecting heroin, and 34% a crack and heroin mix. Nine (26%) of the sample were female and the average age was 39 years (23-53). Two interviews were conducted with each participant, with the second interview incorporating reference to a computer-constructed life history time-line. Interview accounts were audiorecorded, transcribed verbatim and analysed thematically. Hepatitis C risk awareness was recent and deprioritized by the majority of participants. The facilitation of venous access and care was an initial and enduring rationale for safe injecting practices. Difficult venous access resulted in increased contamination of injecting environments and transitions to femoral injecting. Participants expressed an unmet desire for non-judgemental venous access information and advice. Harm reduction interventions which attend to the immediate priorities of people who inject drugs, such as venous access and care, have the potential to re-engage individuals who are jaded or confused by hepatitis C prevention messages. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.
Büller, H R; van der Meer, J; Oudkerk, M
2000-08-05
Diagnosis of clinically suspected deep venous thrombosis is based on a clinical score, serial compression ultrasonography and D-dimer assay. For the diagnosis of pulmonary embolism perfusion scintigraphy, ventilation scintigraphy, echography of the leg veins and pulmonary angiography in that order lead to the lowest mortality, morbidity and costs. Diagnostics with spiral CT followed by pulmonary angiography leads to equal mortality and fewer angiography procedures. Decision rules based on anamnesis, physical examination, blood gas analysis and chest radiograph have proved to be insufficiently reliable. The present D-dimer assays have too little sensitivity and too much variability. Thrombo-prophylaxis with low-molecular-weight heparin is indicated for general surgery, joint replacement of the knee or hip, cranial and spinal surgery, subarachnoid haemorrhage after surgical treatment of an aneurysm, acute myocardial infarction, ischaemic stroke or spinal cord lesion, intensive care patients, patients with acute paralysis due to a neuromuscular disorder, and bedridden patients with a risk factor. Prophylaxis has to be continued as long as the indication exists. In the acute phase of deep venous thrombosis or pulmonary embolism treatment with (low-molecular-weight) heparin in an adequate dose is necessary. When started at the same time as coumarin derivatives the treatment with heparin has to be continued for at least 5 days. The risk of postthrombotic syndrome after deep venous thrombosis will be lowered by carrying compression stockings for at least 2 years after the event.
Lamsfus-Prieto, J Á; de Castro-Fernández, R; Hernández-García, A M; Marcano-Rodriguez, G
2016-04-01
The anaerobic metabolism is the cornerstone in physiopathology of septic shock. Nowadays we have both the central or mixed venous oxygen saturation and lactate levels to monitoring the metabolism in septic patients. Some studies have shown that normalization of systemic hemodynamic and oxygen metabolism variables not prevent progression to multiorgan damage and death. Recently has been proposed the venous-to-arterial carbon dioxide difference (ΔpvaCO2) as an alternative marker of tissue hypoperfusion, like Cardiac Index. High ΔpvaCO2 predicts adverse outcomes. Also has been proposed both, the ratio between the ΔpvaCO2 and arterial-to-venous oxygen content difference (ΔCavO2): ΔpvaCO2/ΔCavO2; and, the ratio between venous-to-arterial carbon dioxide difference (ΔCvaCO2) and ΔCavO2: ΔCvaCO2/ΔCavO2, as markers of anaerobic metabolism. Both of high ratios are related to high levels of lactate and worse prognosis. Therefore in patients with sepsis the combination of markers of resuscitation could be important to improve the outcomes. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Investigation of alternative curb mixes.
DOT National Transportation Integrated Search
1975-01-01
The objective was to design and test mixes that might satisfactorily be used to replace the asbestos curb mix. Tentatively, it was recommended that a Gilsonite mix be used where high stability was required.
Miljic, Dragana; Miljic, Predrag; Doknic, Mirjana; Pekic, Sandra; Stojanovic, Marko; Petakov, Milan; Popovic, Vera
2014-01-01
Adipsic diabetes insipidus (ADI) is a rare disorder. It can occur after transcranial surgery for craniopharyngeoma, suprasellar pituitary adenoma and anterior communicating artery aneurysm but also with head injury, toluene exposure and developmental disorders. It is often associated with significant hypothalamic dysfunction and complications like obesity, sleep apnea, thermoregulatory disorders, seizures and venous thromboembolism (VTE). Morbidity and mortality data have been reported as single case reports with only one large series suggesting increased risk for VTE in patients with ADI. Here we report a mini-series of four patients with ADI and VTE. Post-surgery immobilization, obesity, infection, with prolonged hospitalization, hemoconcentration and changes in coagulation which might be induced by inadequate hormone treatment in the postoperative period (high doses of glucocorticoids, sex steroids and DDAVP replacement) may all contribute to the pathogenesis of VTE. Thromboprophylactic treatment after pituitary surgery and during episodes of hypernatremia is therefore warranted.
Kalantre, Atul; Vettukattil, Joseph; Haw, Marcus; Veldtman, Gruschen R
2007-12-01
Paravalvular leaks are a recognized complication of valve replacement surgery. We report a 47-year-old man with left atrial isomerism, interrupted left sided inferior caval vein with unilateral left sided superior caval vein, a common atrium, and anomalous pulmonary venous connection to the coronary sinus, who had recurrent severe para-right atrioventricular (AV) regurgitation with gross right heart failure following tricuspid valve (TCV) replacement. He underwent a hybrid surgery-transcatheter treatment strategy in the cardiac catheterization laboratory, which led to significant improvement in hemodynamics and symptoms. This to our knowledge is the first reported case of a minimally invasive approach to para-right sided AV valve regurgitation.
Soy foods and soybean isoflavones and menopausal health.
Messina, Mark J
2002-01-01
Soybeans are a natural dietary source of isoflavones, which have estrogen-like properties. Therefore, it is worthwhile to consider the implications for soy of the recently published findings of the Heart and Estrogen/Progestin Replacement Study (HERS) I/II and the Women's Health Initiative (WHI). The WHI found coronary heart disease (CHD) risk to be increased in women receiving hormone replacement therapy, and both studies found increases in venous thromboembolic disease in such women. Additionally, stroke and breast cancer risk were increased in the WHI, although risk of colorectal cancer and fracture was decreased. Because research suggests that it is the combination of estrogen plus progestin, and not estrogen alone, that increases breast cancer risk, soy seems unlikely to increase risk because it has no progestin activity. Similarly, there is no evidence to suggest that soy will increase venous thromboembolic disease or stroke; however, only limited data are available in this area. There are promising data suggesting that soy may decrease CHD risk, although studies conducted thus far have examined only markers of risk and not actual CHD events. Similarly, short-term studies generally suggest that soy reduces bone loss in postmenopausal women; however, such effects have been noted primarily only at the spine, and longer-term studies are needed. Finally, very limited human research suggests that soy may decrease colon cancer risk, but this is highly speculative. The results of HERS I/II and WHI suggest that soy may have some of the advantages, but not the disadvantages, of combined hormone replacement therapy (at least with respect to the specific hormones and doses used in the HERS I/II and WHI), but that large, long-term intervention studies examining disease outcome are needed before definitive conclusions can be drawn. Nevertheless, the evidence warrants recommendations that menopausal women include soy in their diets.
Hemodialysis tunneled central venous catheters: five-year outcome analysis.
Mandolfo, Salvatore; Acconcia, Pasqualina; Bucci, Raffaella; Corradi, Bruno; Farina, Marco; Rizzo, Maria Antonietta; Stucchi, Andrea
2014-01-01
Tunneled central venous catheters (tCVCs) are considered inferior to arteriovenous fistulas (AVFs) and grafts in all nephrology guidelines. However, they are being increasingly used as hemodialysis vascular access. The purpose of this study was to document the natural history of tCVCs and determine the rate and type of catheter replacement. This was a prospective study of 141 patients who underwent hemodialysis with tCVCs between January 2008 and December 2012. The patients used 154 tCVCs. Standard protocols about management of tCVCs, according to European Renal Best Practice, were well established. All catheters were inserted in the internal jugular vein. Criteria for catheter removal were persistent bloodstream infection, detection of an outbreak of catheter-related bloodstream (CRBS) infections, or catheter dysfunction. Event rates were calculated per 1,000 catheter days; tCVC cumulative survival was estimated by Kaplan-Meier analysis. Catheter replacement occurred in 15 patients (0.29 per 1,000 days); catheter dysfunction was the main cause of replacement (0.18 per 1,000 days), typically within 12 months of surgical insertion. A total of 53 CRBS events in 36 patients were identified (0.82 per 1,000 days); 17 organisms, most commonly Gram-positive pathogens, were isolated; 87% of CVC infections were treated by systemic antibiotics associated with lock therapy. tCVC cumulative survival was 91% at 1 year, 88% at 2 years and 85% at 4 years. Our data show a high survival rate of tCVCs in hemodialysis patients, with low incidence of catheter dysfunction and CRBS events. These data justify tCVC use for hemodialysis vascular access, also as first choice, especially in patients with exhausted peripheral access and limited life expectancy.
Hickey, Edward J; McCrindle, Brian W; Blackstone, Eugene H; Yeh, Thomas; Pigula, Frank; Clarke, David; Tchervenkov, Christo I; Hawkins, John
2008-05-01
Limited availability and durability of allograft conduits require that alternatives be considered. We compared bovine jugular venous valved (JVV) and allograft conduit performance in 107 infants who survived truncus arteriosus repair. Children were prospectively recruited between 2003 and 2007 from 17 institutions. The median z-score for JVV (n=27, all 12 mm) was +2.1 (range +1.2 to +3.2) and allograft (n=80, 9-15mm) was +1.7 (range -0.4 to +3.6). Propensity-adjusted comparison of conduit survival was undertaken using parametric risk-hazard analysis and competing risks techniques. All available echocardiograms (n=745) were used to model deterioration of conduit function in regression equations adjusted for repeated measures. Overall conduit survival was 64+/-9% at 3 years. Conduit replacement was for conduit stenosis (n=16) and/or pulmonary artery stenosis (n=18) or regurgitation (n=1). The propensity-adjusted 3-year freedom from replacement for in-conduit stenosis was 96+/-4% for JVV and 69+/-8% for allograft (p=0.05). The risk of intervention or replacement for branch pulmonary artery stenosis was similar for JVV and allograft. Smaller conduit z-score predicted poor conduit performance (p<0.01) with best outcome between +1 and +3. Although JVV conduits were a uniform diameter, their z-score more consistently matched this ideal. JVV exhibited a non-significant trend towards slower progression of conduit regurgitation and peak right ventricular outflow tract (RVOT) gradient. In addition, catheter intervention was more successful at slowing subsequent gradient progression in children with JVV versus those with allograft (p<0.01). JVV does match allograft performance and may be advantageous. It is an appropriate first choice for repair of truncus arteriosus, and perhaps other small infants requiring RVOT reconstruction.
Vendramin, Chiara; McGuckin, Siobhan; Alwan, Ferras; Westwood, John-Paul; Thomas, Mari; Scully, Marie
2017-01-01
Patients presenting with acute episodes of thrombotic microangiopathies (TMAs) require urgent access to plasma exchange (PEX). OctaplasLG, a solvent/detergent fresh-frozen plasma product that has undergone viral inactivation and prion reduction step, has been used in our institution since 2013, replacing Octaplas. We prospectively reviewed 981 PEX procedures where OctaplasLG was the replacement fluid in 90 patients admitted acutely with a TMA presentation within our institution from January 1, 2013, to December 31, 2015. We recorded citrate toxicities, plasma reactions, viral transfer, complications related to central venous catheter, and venous thrombotic events (VTEs). Citrate toxicities were 5.4%, plasma reactions were 2%, and all were classified as Grade 1 or 2. VTE had an incidence of 12.2%, although 50% of the episodes occurred in early remission when patients were not receiving PEX. No line insertions complications were recorded. Line-associated infections were 2.2%. Hepatitis B and C serology and human immunodeficiency virus (HIV) were checked on admission. There were four patients who may have had passive transient transfer of hepatitis B antibodies from pooled plasma. No hepatitis C or HIV viral transfer was documented after treatment and no seroconversion was detected after treatment. Our data have demonstrated that the incidence of complications during PEX is low and using OctaplasLG is comparable to the low incidence of reactions. No cases of anaphylaxis, transfusion-related acute lung injury, or fatal plasma reactions were seen. There was no evidence of viral transmission or seroconversion after treatment. © 2016 AABB.
Seki, Tatsuya; Hattori, Atsuo; Yoshida, Toshihito
2017-08-01
We report a case of hemodynamic deterioration after aortic valve replacement in a patient with mixed systemic amyloidosis. A 77-year-old male with severe aortic valve stenosis and 19 years hemodialysis underwent aortic valve replacement. Postoperatively, the patient died of hemodynamic deterioration. Autopsy findings showed massive, whole-body edema and mixed systemic amyloidosis (dialysis-related and AA amyloidosis). Clinical and autopsy findings implied that hemodynamic deterioration was caused by increased vascular permeability. The amyloid deposit to the vessel causes inflammatory changes and increases vascular permeability. Mixed systemic amyloidosis occurs very rarely and could increases vascular permeability even more than each single type of amyloidosis. Systemic amyloidosis may be a risk factor for hemodynamic deterioration after cardiac surgery. Patients with longtime hemodialysis and a history associated with dialysis-related amyloidosis would have at least single systemic amyloidosis, which should be considered a contraindication to cardiac surgery with cardiopulmonary bypass.
An experimental investigation on mechanical behaviour of eco - friendly concrete
NASA Astrophysics Data System (ADS)
Narender Reddy, A.; Meena, T.
2017-11-01
Fly ash (FA) and Alccofine are the eco-friendly materials that can be used in the production of concrete composites. Initially, concrete mixes of M30 grade with replacement of cement by 0%, 5%, 10%, 15%, 20% and 25% by weight of Fly ash were prepared. They were subjected to compression test so as to select the optimum replacement percentage of FA. Keeping this optimum percentage of FA as constant, additional replacement of cement with Alccofine was done varying its replacement in the range of 8%, 10%, 12% and 14%. The mechanical properties such as compressive, split tensile and flexural strengths of these mixes were computed for 7, 14 and 28 days. The results of Eco-Friendly Concrete (EFC) are compared with those of control concrete. It was observed that EFC mixes exhibited superior qualities like quick setting and enhanced workability, their mechanical properties were found to be higher than that of the conventional concrete. This goes to prove that the combination of FA and Alccofine together as replacement for cement would enhance the properties of EFC.
Kotirum, Surachai; Chongmelaxme, Bunchai; Chaiyakunapruk, Nathorn
2017-02-01
To analyze the cost-utility of oral dabigatran etexilate, enoxaparin sodium injection, and no intervention for venous thromboembolism (VTE) prophylaxis after total hip or knee replacement (THR/TKR) surgery among Thai patients. A cost-utility analysis using a decision tree model was conducted using societal and healthcare payers' perspectives to simulate relevant costs and health outcomes covering a 3-month time horizon. Costs were adjusted to year 2014. The willingness-to-pay threshold of THB 160,000 (USD 4926) was used. One-way sensitivity and probabilistic sensitivity analyses using a Monte Carlo simulation were performed. Compared with no VTE prophylaxis, dabigatran and enoxaparin after THR and TKR surgery incurred higher costs and increased quality adjusted life years (QALYs). However, their incremental cost-effectiveness ratios were high above the willingness to pay. Compared with enoxaparin, dabigatran for THR/TKR lowered VTE complications but increased bleeding cases; dabigatran was cost-saving by reducing the costs [by THB 3809.96 (USD 117.30) for THR] and producing more QALYs gained (by 0.00013 for THR). Dabigatran (vs. enoxaparin) had a 98 % likelihood of being cost effective. Dabigatran is cost-saving compared to enoxaparin for VTE prophylaxis after THR or TKR under the Thai context. However, both medications are not cost-effective compared to no thromboprophylaxis.
Durability and Strength of Sustainable Self-Consolidating Concrete Containing Fly Ash
NASA Astrophysics Data System (ADS)
Mohamed, O.; Hawat, W. Al
2018-03-01
In this paper, the durability and strength of self-consolidating concrete (SCC) is assessed through development and testing of six binary mixes at fixed water-to-binder (w/b) ratio of 0.36. In each of the six SCC mixes, a different percentage of cement is replaced with fly ash. The development of compressive strength for each of the mixes is assessed by testing samples after 3, 7, and 28 days of curing. Durability of each of the six SCC mixes is assessed by measuring the charge passed in Rapid Chloride Permeability (RCP) test. Charge passed was measured in samples cured for 1, 3, 7, 14, 28, and 40 days of curing. All mixes out-performed the control mix in terms of resistance to chloride penetration. Binary mix in which 20% of cement is replaced with fly ash exhibited 28-day strength slightly surpassing the control mix.
Tricco, Andrea C; Cogo, Elise; Isaranuwatchai, Wanrudee; Khan, Paul A; Sanmugalingham, Geetha; Antony, Jesmin; Hoch, Jeffrey S; Straus, Sharon E
2015-04-22
Complex wounds present a substantial economic burden on healthcare systems, costing billions of dollars annually in North America alone. The prevalence of complex wounds is a significant patient and societal healthcare concern and cost-effective wound care management remains unclear. This article summarizes the cost-effectiveness of interventions for complex wound care through a systematic review of the evidence base. We searched multiple databases (MEDLINE, EMBASE, Cochrane Library) for cost-effectiveness studies that examined adults treated for complex wounds. Two reviewers independently screened the literature, abstracted data from full-text articles, and assessed methodological quality using the Drummond 10-item methodological quality tool. Incremental cost-effectiveness ratios were reported, or, if not reported, calculated and converted to United States Dollars for the year 2013. Overall, 59 cost-effectiveness analyses were included; 71% (42 out of 59) of the included studies scored 8 or more points on the Drummond 10-item checklist tool. Based on these, 22 interventions were found to be more effective and less costly (i.e., dominant) compared to the study comparators: 9 for diabetic ulcers, 8 for venous ulcers, 3 for pressure ulcers, 1 for mixed venous and venous/arterial ulcers, and 1 for mixed complex wound types. Our results can be used by decision-makers in maximizing the deployment of clinically effective and resource efficient wound care interventions. Our analysis also highlights specific treatments that are not cost-effective, thereby indicating areas of resource savings. Please see related article: http://dx.doi.org/10.1186/s12916-015-0288-5.
NASA Astrophysics Data System (ADS)
Azmi, N. B.; Khalid, F. S.; Irwan, J. M.; Anting, N.; Mazenan, P. N.
2017-11-01
Natural fine aggregate materials are commonly used in development and commercial construction in Malaysia. In fact, concrete production was increased as linear with the growing Malaysia economy. However, an issue was production of concrete was to locate adequate sources of natural fine aggregates. There lot of studies have been conducted in order to replace the fine aggregate in which natural fine aggregate replace with the waste material in concrete preparation. Therefore, this study aims to utilize the Recycled Concrete Aggregate (RCA) and ceramic waste which has great potential to replace the natural aggregate in concrete mix with different type of method, admixture, and parameters. This research were focused on compressive strength and water absorption test to determine the optimum mix ratio of concrete mix. The concrete aggregate was chosen due to improvement capillary bonding mechanisms and ceramic presented similar strength compared to the conventional concrete using natural aggregate. Percent of replacement have been used in this study was at 25%, 35% and 45% of the RCA and 5%, 10% and 15% for ceramic, respectively. Furthermore, this research was conduct to find the optimum percentage of aggregate replacement, using water-cement ratio of 0.55 with concrete grade 25/30. The best percentage of replacement was the RCA35% C15% with the compressive strength of 34.72 MPa and the water absorption was satisfied.
Welsh, Lynn
2017-05-01
To analyse current evidence on the efficacy of bandage systems containing both elastic and inelastic components (mixed-component systems). International consensus on the efficacy of types of compression systems is difficult to achieve; however, mixed-component systems are being promoted as combining the best properties of both elastic and inelastic bandage systems and increasingly being used to treat venous leg ulcers in practice. A systematic literature review. Search terms such as venous leg ulcer, varicose ulcer, leg ulcer, compression, bandage, elastic, inelastic, short stretch, healing rate, interface pressure, mixed component, two-layer, four-layer and multi-layer were used in database and hand searches in several combinations. Limits were set for years 2005-March 2015 and English-language publications. A total of 475 studies were identified at initial search, and following elimination from abstract and title, this was reduced to 7. A further study was identified on Google Scholar, bringing the final number of studies fitting inclusion criteria to 8. The following subgroups relating to outcomes of efficacy were identified: ulcer healing, maintenance of interface pressure, slippage, ease of application and patient quality of life. Mixed-component systems were found to have comparable ulcer healing rates to alternative compression systems and be easy to apply; have similar abilities to maintain pressure as four-layer bandages and better abilities than short-stretch bandages; have less slippage than alternative systems; and to be significantly associated with several favourable quality of life outcomes. Clinician skill in bandage application was an uncontrolled variable in all eight papers included in the review, which may limit reliability of findings. This review synthesises existing evidence on the efficacy of mixed-component systems and encourages clinicians to regard them as an effective alternative to purely elastic or inelastic compression systems. Additionally, it highlights the importance of clinician skill in bandage application as a crucial determinant of effective compression. © 2016 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Nirmala, D. B.; Raviraj, S.
2016-06-01
This paper presents the application of Taguchi approach to obtain optimal mix proportion for Self Compacting Concrete (SCC) containing spent foundry sand and M-sand. Spent foundry sand is used as a partial replacement for M-sand. The SCC mix has seven control factors namely, Coarse aggregate, M-sand with Spent Foundry sand, Cement, Fly ash, Water, Super plasticizer and Viscosity modifying agent. Modified Nan Su method is used to proportion the initial SCC mix. L18 (21×37) Orthogonal Arrays (OA) with the seven control factors having 3 levels is used in Taguchi approach which resulted in 18 SCC mix proportions. All mixtures are extensively tested both in fresh and hardened states to verify whether they meet the practical and technical requirements of SCC. The quality characteristics considering "Nominal the better" situation is applied to the test results to arrive at the optimal SCC mix proportion. Test results indicate that the optimal mix satisfies the requirements of fresh and hardened properties of SCC. The study reveals the feasibility of using spent foundry sand as a partial replacement of M-sand in SCC and also that Taguchi method is a reliable tool to arrive at optimal mix proportion of SCC.
Razi, Putri Zulaiha; Abdul Razak, Hashim; Khalid, Nur Hafizah A
2016-05-06
This study investigates the engineering performance and CO₂ footprint of mortar mixers by replacing Portland cement with 10%, 20%, 40% and 60% fly ash, a common industrial waste material. Samples of self-compacting mortar (SCM) were prepared with four different water/binder ratios and varying dosages of superplasticizer to give three ranges of workability, i.e. , normal, high and self-compacting mortar mix. The engineering performance was assessed in term of compressive strength after designated curing periods for all mixes. CO₂ footprint was the environmental impact indicator of each production stage. The optimum mix obtained was at 10% replacement rate for all mixes. Total production emission reduced by 56% when the fly ash replacement rate increased from 0% to 60% (maximum). This is translated to a reduction of 80% in eco-points (assuming that the energy consumption rate of production with 0% fly ash is at 100%). Such re-utilization is encouraged since it is able to reduce possible soil toxicity due to sulfur leaching by 5% to 27% and landfill area by 15% to 91% on average.
Razi, Putri Zulaiha; Abdul Razak, Hashim; Khalid, Nur Hafizah A.
2016-01-01
This study investigates the engineering performance and CO2 footprint of mortar mixers by replacing Portland cement with 10%, 20%, 40% and 60% fly ash, a common industrial waste material. Samples of self-compacting mortar (SCM) were prepared with four different water/binder ratios and varying dosages of superplasticizer to give three ranges of workability, i.e., normal, high and self-compacting mortar mix. The engineering performance was assessed in term of compressive strength after designated curing periods for all mixes. CO2 footprint was the environmental impact indicator of each production stage. The optimum mix obtained was at 10% replacement rate for all mixes. Total production emission reduced by 56% when the fly ash replacement rate increased from 0% to 60% (maximum). This is translated to a reduction of 80% in eco-points (assuming that the energy consumption rate of production with 0% fly ash is at 100%). Such re-utilization is encouraged since it is able to reduce possible soil toxicity due to sulfur leaching by 5% to 27% and landfill area by 15% to 91% on average. PMID:28773465
Merkelbach, D; Brandt, L; Mertzlufft, F
1993-10-01
The Christiansen-Douglas-Haldane effect describes the reduced CO2 binding capacity of oxygenated compared to deoxygenated haemoglobin. Under the condition of a "closed system", for example hyperoxic apnoea after adequate preoxygenation (continuous O2 uptake with lack of CO2 delivery), specific effects on the arterial and mixed venous blood gas status, due to the Haldane effect, are seen: within 30 s after onset of apnoea, "paradoxical pCO2" (paCO2 exceeds pvCO2) and "pH reversal" (pHa falls under pHv) can be observed. It was the aim of this study to demonstrate how fast arterial and mixed venous pCO2 and pH normalize when a change from apnoea ("closed system") to controlled ventilation ("open system") takes place. METHODS. 12 patients (ASA II-IV, NYHA II-III) scheduled for coronary artery bypass grafting were studied. Premedication consisted of flunitrazepam 2.0 mg p.o. given the evening before operation and another 2.0 mg p.o. given 90-120 min before induction of anaesthesia. Routine preparation for induction consisted of venous and arterial cannulas, pulmonary artery catheter and continuous pulse oximetry. Following standardized preoxygenation, induction of anaesthesia was performed with fentanyl, pancuronium and etomidate. After cessation of spontaneous respiration, controlled ventilation was continued with 100% O2 until intubation. Intubation and insertion of stomach tube and oesophageal temperature probe were undertaken after exactly 2 min. After reconnection to the semi-closed circle breathing system, controlled ventilation was continued with 100% O2. Eighteen arterial (a) and 18 mixed-venous (v) blood samples were drawn simultaneously in a sequential manner immediately before and during the last 20 s of apnoea, as well as within 4 min after onset of controlled ventilation (Table 1). The pO2 (mmHg), pCO2 (mmHg) and pH were determined using a Stat Profile 5 blood gas analyser. RESULTS. During apnoea and within the first 35 s of controlled ventilation the paO2 showed a total decrease of 131.5 mmHg that was followed by an almost linear increase of 29.7 mmHg/min (Fig. 1a). In the course of apnoea and controlled ventilation the pvO2 remained relatively stable, with values ranging from 42 to 43 mmHg (Fig. 1b). During apnoea the paCO2 showed an increase of 12.5 mmHg that was followed by a biphasic decrease (first 13.8 mmHg/min and then 0.75 mmHg/min) beginning 15 s after the onset of controlled ventilation (Fig. 2a). With an increase of 4.2 mmHg, the pvCO2 showed about a third of the increase of the paCO2 during apnoea, reaching a maximum 45 s after the onset of controlled ventilation and then being followed by a linear decrease of 0.86 mmHg/min (Fig.2b). Comparing the course of paCO2 and pvCO2 during apnoea as well as during the period of controlled ventilation, pHa and pHv changed in a reciprocal manner (Fig. 3a/b). The so-called normalization of pCO2 (paCO2 falls under pvCO2) and pH (pHa exceeds pHv) began 18.2 s and 23.2 s respectively after the onset of controlled ventilation (Fig. 4a, b). CONCLUSION. Considering the expected decrease of paO2 during hyperoxic apnoea, insufficient pulmonary N2 elimination prior to the onset of apnoea, as well as direct N2 delivery into the alveoli, due to the so-called a ventilatory mass flow, will limit unrestricted pulmonary O2 uptake. The continuing decrease of the paCO2 after the onset of controlled ventilation can be regarded as indirect proof of a ventilatory mass flow. The course of pCO2 and pH after the onset of controlled ventilation shows that normalization in arterial and mixed-venous blood gas status takes place in about 18.2 s after the cessation of apnoea.
NASA Astrophysics Data System (ADS)
Mat Aris, S.; Muthusamy, K.; Uzer, A.; Ahmad, S. Wan
2018-04-01
Environmental pollution caused by the disposal of solid wastes generated from both palm oil industry and cockle shell trade has motivated researches to explore the potential of these wastes. Integrating these wastes in production of construction material is one of the ways to reduce amount of waste thrown at dumping area. Thus, the present investigation investigates the performance of palm oil fuel ash (POFA) cement sand brick containing pulverized cockle shell as partial fine aggregate replacement. All mixes used contain 20% of POFA as partial cement replacement. Total of six mixes were prepared by adding a range of pulverized cockle shell that is 0%, 10%, 20%, 30%, 40% and 50% as partial sand replacement. The mixes were prepared in form of brick. All the water cured samples were tested for compressive strength and flexural strength until 28 days. Findings show that brick produced using 20% pulverized cockle shell exhibit the highest compressive strength and flexural strength also the lowest water absorption value.
Kwak, Hyun Jeong; Kim, Ji Young; Kim, Yong Beom; Min, Sang Kee; Moon, Bong Ki; Kim, Jong Yeop
2013-10-01
Rocuronium is reported to be associated with injection pain or withdrawal movement (IPWM). This meta-analysis assessed the efficacy of different pharmacological treatments used to decrease the incidence of the rocuronium-induced IPWM. We searched the Cochrane Library, Embase and PubMed for randomized controlled trials comparing a pharmacological drug with a placebo to prevent the rocuronium-induced IPWM and found 37 studies with 5,595 patients. Overall incidence of rocuronium-induced IPWM was 74%. Pretreatment with opioids [risk ratio (RR) 0.16; 95% confidence interval (95% CI) 0.09-0.29], lidocaine (0.47; 0.35-0.64), and ketamine (0.41; 0.22-0.77) were effective in decreasing IPWM. Lidocaine pretreatment with venous occlusion (0.40; 0.32-0.49) and opioids pretreatment with venous occlusion (0.77; 0.61-0.96) were also effective. Mixing sodium bicarbonate (NaHCO3) with rocuronium (0.15; 0.06-0.34) was also efficacious in reducing IPWM. Indirect comparison shows that the RR of NaHCO3 admixture and pretreatment with opioids were lower than that of the other four interventions (pretreatments of ketamine or lidocaine, and lidocaine or opioids with venous occlusion). This meta-analysis suggests that opioids, lidocaine, ketamine, and NaHCO3 are effective in decreasing rocuronium-induced IPWM. Considering the efficacy and convenience, pretreatment with opioids without venous occlusion is recommended for reducing rocuronium-induced IPWM.
Hopf, H-B; Hochscherf, M; Jehmlich, M; Leischik, M; Ritter, J
2007-07-01
This paper describes the introduction of a single-pass batch hemodialysis system for renal replacement therapy in a 14 bed intensive care unit. The goals were to reduce the workload of intensive care unit physicians using an alternative and simpler method compared to continuous veno-venous hemodiafiltration (CVVHDF) and to reduce the costs of hemofiltrate solutions (80,650 EUR per year in our clinic in 2005). We describe and evaluate the process of implementation of the system as well as the achieved and prospective savings. We conclude that a close cooperation of all participants (physicians, nurses, economists, technicians) of a hospital can achieve substantial benefits for patients and employees as well as reduce the economic burden of a hospital.
Skopets, A A; Lomivorotov, V V; Karakhalis, N B; Makarov, A A; Duman'ian, E S; Lomivorotova, L V
2009-01-01
The purpose of the study was to evaluate the efficiency of oxygen-transporting function of the circulatory system under sevoflurane anesthesia during myocardial revascularization operations under extracorporeal circulation. Twenty-five patients with coronary heart disease were examined. Mean blood pressure, heart rate, cardiac index, total peripheral vascular resistance index, pulmonary pressure, pulmonary wedge pressure, and central venous pressure were measured. Arterial and mixed venous blood oxygen levels, oxygen delivery and consumption index, arteriovenous oxygen difference, and glucose and lactate concentrations were calculated. The study has demonstrated that sevoflurane is an effective and safe anesthetic for myocardial revascularization operations in patients with coronary heart disease. The use of sevoflurane contributes to steady-state oxygen-transporting function of the circulatory system at all surgical stages.
Clinical Evaluation of the BD FACSPresto™ Near-Patient CD4 Counter in Kenya
Angira, Francis; Akoth, Benta; Omolo, Paul; Opollo, Valarie; Bornheimer, Scott; Judge, Kevin; Tilahun, Henok; Lu, Beverly; Omana-Zapata, Imelda; Zeh, Clement
2016-01-01
Background The BD FACSPresto™ Near-Patient CD4 Counter was developed to expand HIV/AIDS management in resource-limited settings. It measures absolute CD4 counts (AbsCD4), percent CD4 (%CD4), and hemoglobin (Hb) from a single drop of capillary or venous blood in approximately 23 minutes, with throughput of 10 samples per hour. We assessed the performance of the BD FACSPresto system, evaluating accuracy, stability, linearity, precision, and reference intervals using capillary and venous blood at KEMRI/CDC HIV-research laboratory, Kisumu, Kenya, and precision and linearity at BD Biosciences, California, USA. Methods For accuracy, venous samples were tested using the BD FACSCalibur™ instrument with BD Tritest™ CD3/CD4/CD45 reagent, BD Trucount™ tubes, and BD Multiset™ software for AbsCD4 and %CD4, and the Sysmex™ KX-21N for Hb. Stability studies evaluated duration of staining (18–120-minute incubation), and effects of venous blood storage <6–24 hours post-draw. A normal cohort was tested for reference intervals. Precision covered multiple days, operators, and instruments. Linearity required mixing two pools of samples, to obtain evenly spaced concentrations for AbsCD4, total lymphocytes, and Hb. Results AbsCD4 and %CD4 venous/capillary (N = 189/ N = 162) accuracy results gave Deming regression slopes within 0.97–1.03 and R2 ≥0.96. For Hb, Deming regression results were R2 ≥0.94 and slope ≥0.94 for both venous and capillary samples. Stability varied within 10% 2 hours after staining and for venous blood stored less than 24 hours. Reference intervals results showed that gender—but not age—differences were statistically significant (p<0.05). Precision results had <3.5% coefficient of variation for AbsCD4, %CD4, and Hb, except for low AbsCD4 samples (<6.8%). Linearity was 42–4,897 cells/μL for AbsCD4, 182–11,704 cells/μL for total lymphocytes, and 2–24 g/dL for Hb. Conclusions The BD FACSPresto system provides accurate, precise clinical results for capillary or venous blood samples and is suitable for near-patient CD4 testing. Trial Registration ClinicalTrials.gov NCT02396355 PMID:27483008
Sandeu, Maurice M; Bayibéki, Albert N; Tchioffo, Majoline T; Abate, Luc; Gimonneau, Geoffrey; Awono-Ambéné, Parfait H; Nsango, Sandrine E; Diallo, Diadier; Berry, Antoine; Texier, Gaétan; Morlais, Isabelle
2017-08-17
The measure of new drug- or vaccine-based approaches for malaria control is based on direct membrane feeding assays (DMFAs) where gametocyte-infected blood samples are offered to mosquitoes through an artificial feeder system. Gametocyte donors are identified by the microscopic detection and quantification of malaria blood stages on blood films prepared using either capillary or venous blood. However, parasites are known to sequester in the microvasculature and this phenomenon may alter accurate detection of parasites in blood films. The blood source may then impact the success of mosquito feeding experiments and investigations are needed for the implementation of DMFAs under natural conditions. Thick blood smears were prepared from blood obtained from asymptomatic children attending primary schools in the vicinity of Mfou (Cameroon) over four transmission seasons. Parasite densities were determined microscopically from capillary and venous blood for 137 naturally-infected gametocyte carriers. The effect of the blood source on gametocyte and asexual stage densities was then assessed by fitting cumulative link mixed models (CLMM). DMFAs were performed to compare the infectiousness of gametocytes from the different blood sources to mosquitoes. Prevalence of Plasmodium falciparum asexual stages among asymptomatic children aged from 4 to 15 years was 51.8% (2116/4087). The overall prevalence of P. falciparum gametocyte carriage was 8.9% and varied from one school to another. No difference in the density of gametocyte and asexual stages was found between capillary and venous blood. Attempts to perform DMFAs with capillary blood failed. Plasmodium falciparum malaria parasite densities do not differ between capillary and venous blood in asymptomatic subjects for both gametocyte and trophozoite stages. This finding suggests that the blood source should not interfere with transmission efficiency in DMFAs.
Structural locus of transmucosal albumin efflux in canine ileum. A fluorescent study.
Granger, D N; Cook, B H; Taylor, A E
1976-12-01
This study demonstrates the effects of elevated intestinal venous pressure on the intestinal tissue spaces and the histological locus of the transmucosal albumin flux under such conditions. The authors were able to localize albumin in the tissues using an Evans blue-albumin fluorescence technique. This technique makes use of the fluorescence properties and albumin affinity of Evans blue dye (T-1824). Evans blue dye has a high affinity for albumin and emits a red-orange fluorescence at a wavelength of 720 nm. Evans blue was mixed with a solution of bovine serum albumin at concentrations that yield negligible amounts of free dye. Control ileal samples were obtained in order to visualize the natural tissue morphology and fluorescence. The Evans blue-albumin solution was injected and tissue samples were obtained 15 and 60 min postinjection, then venous outflow was occluded and after 15 and 60 min the tissues were sampled. Each sample was immediately frozen, freeze dried, embedded in paraffin, and 7-mu sections were made. The Evans blue-albumin was demonstrated histologically with a fluorescence microscope. No leakage sites were apparent at normal venous pressures. However, after elevation of venous pressure, Evans blue-albumin was observed in the interepithelial and/or intraepithelial spaces of villus tips, but no Evans blue-albumin was observed either between or within the epithelial cells of the crypts, or within the tubular crypt lumina. These results indicate that at elevated venous pressures, the transmucosal albumin flux occurs exclusively at the villus tip region, suggesting a great vulnerability of the cells found in this region to elevations in tissue pressure as compared to the crypt epithelial cells.
Histologic Fate of the Venous Coronary Artery Bypass in Dogs
Brody, William R.; Angell, William W.; Kosek, Jon C.
1972-01-01
The histologic fate of venous grafts used for coronary artery bypass has been observed with light and electron microscopy in dogs. Endothelial damage and thrombosis were chiefly limited to the first postoperative week. The muscular media uniformly suffered extensive necrosis and inflammatory cell infiltration during the first week. Its smooth muscle cells either hypertrophied, died or underwent apparent fibroblastic transformation, with eventual fibrous replacement, to a variable degree, of the vein wall. Vascular wall ischemia due to interruption of vasa vasorum during transplantation appears to initiate these medial changes. Much more slowly, intimal thickening by myointimal cells and collagen may reduce the graft lumen to a variable extent. ImagesFig 8Fig 9Fig 18Fig 19Fig 20Fig 21Fig 1Fig 2Fig 3Fig 10Fig 11Fig 12Fig 22Fig 23Fig 24Fig 25Fig 13Fig 14Fig 4Fig 5Fig 6Fig 7Fig 15Fig 16Fig 17 PMID:5009248
Neutron radiation shielding properties of polymer incorporated self compacting concrete mixes.
Malkapur, Santhosh M; Divakar, L; Narasimhan, Mattur C; Karkera, Narayana B; Goverdhan, P; Sathian, V; Prasad, N K
2017-07-01
In this work, the neutron radiation shielding characteristics of a class of novel polymer-incorporated self-compacting concrete (PISCC) mixes are evaluated. Pulverized high density polyethylene (HDPE) material was used, at three different reference volumes, as a partial replacement to river sand in conventional concrete mixes. By such partial replacement of sand with polymer, additional hydrogen contents are incorporated in these concrete mixes and their effect on the neutron radiation shielding properties are studied. It has been observed from the initial set of experiments that there is a definite trend of reductions in the neutron flux and dose transmission factor values in these PISCC mixes vis-à-vis ordinary concrete mix. Also, the fact that quite similar enhanced shielding results are recorded even when reprocessed HDPE material is used in lieu of the virgin HDPE attracts further attention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pedersen, A B; Mehnert, F; Sorensen, H T; Emmeluth, C; Overgaard, S; Johnsen, S P
2014-04-01
We examined the risk of thrombotic and major bleeding events in patients undergoing total hip and knee replacement (THR and TKR) treated with thromboprophylaxis, using nationwide population-based databases. We identified 83 756 primary procedures performed between 1997 and 2011. The outcomes were symptomatic venous thromboembolism (VTE), myocardial infarction (MI), stroke, death and major bleeding requiring hospitalisation within 90 days of surgery. A total of 1114 (1.3%) and 483 (0.6%) patients experienced VTE and bleeding, respectively. The annual risk of VTE varied between 0.9% and 1.6%, and of bleeding between 0.4% and 0.8%. The risk of VTE and bleeding was unchanged over a 15-year period. A total of 0.7% of patients died within 90 days, with a decrease from 1% in 1997 to 0.6% in 2011 (p < 0.001). A high level of comorbidity and general anaesthesia were strong risk factors for both VTE and bleeding, with no difference between THR and TKR patients. The risk of both MI and stroke was 0.5%, which remained unchanged during the study period. In this cohort study of patients undergoing THR and TKR patients in routine clinical practice, approximately 3% experienced VTE, MI, stroke or bleeding. These risks did not decline during the 15-year study period, but the risk of dying fell substantially.
Is there resetting of central venous pressure in microgravity?
NASA Technical Reports Server (NTRS)
Convertino, V. A.; Ludwig, D. A.; Elliott, J. J.; Wade, C. E.
2001-01-01
In the early phase of the Space Shuttle program, NASA flight surgeons implemented a fluid-loading countermeasure in which astronauts were instructed to ingest eight 1-g salt tablets with 960 ml of water approximately 2 hours prior to reentry from space. This fluid loading regimen was intended to enhance orthostatic tolerance by replacing circulating plasma volume reduced during the space mission. Unfortunately, fluid loading failed to replace plasma volume in groundbased experiments and has proven minimally effective as a countermeasure against post-spaceflight orthostatic intolerance. In addition to the reduction of plasma volume, central venous pressure (CVP) is reduced during exposure to actual and groundbased analogs of microgravity. In the present study, we hypothesized that the reduction in CVP due to exposure to microgravity represents a resetting of the CVP operating point to a lower threshold. A lower CVP 'setpoint' might explain the failure of fluid loading to restore plasma volume. In order to test this hypothesis, we conducted an investigation in which we administered an acute volume load (stimulus) and measured responses in CVP, plasma volume and renal functions. If our hypothesis is true, we would expect the elevation in CVP induced by saline infusion to return to its pre-infusion levels in both HDT and upright control conditions despite lower vascular volume during HDT. In contrast to previous experiments, our approach is novel in that it provides information on alterations in CVP and vascular volume during HDT that are necessary for interpretation of the proposed CVP operating point resetting hypothesis.
Slavin, Richard E; Inada, Kiyoshi
2007-04-01
The authors review 20 cases of segmental arterial mediolysis (SAM) including 3 newly reported cases. SAM developed in areas of vascular distention in 2 of the latter cases: 1 in utero in the heart of a recipient of a twin transfusion syndrome and the other in the jejunum secondary to partial venous obstruction. In the third case, it occurred in a patient with Raynaud disease. Characterizing SAM are injurious and reparative lesions that occur in the media and/or at the adventitial medial junction. Four distinctive alterations are recognized: (1) mediolysis, (2) a tearing separation of the outer media from adventitia, (3) arterial gaps, and (4) a florid reparative response that replaces zones of mediolysis and fills areas of medial adventitial separation. The repair can transform SAM into lesions indistinguishable from common types of fibromuscular dysplasia (FMD.) A venous angiopathy involving large and medium-sized veins accompanies SAM. It features medial muscle vacuolar change with lysis leading to apparent separation of residual muscle bundles. Immunostaining shows endothelin-1 (ET-1) decorating adventitial capillaries in SAM and neighboring arteries, in capillaries of adjoining tissues, and outlining smooth muscle cell membranes in adjacent veins including those of the venous angiopathy. The significance of these changes is uncertain. Vasospasm is believed to cause SAM, but ET-1 is not the direct pressor agent responsible for this condition. The reason(s) for synthesis and release of ET-1 in SAM are still hypothetical, but local perturbations in vascular tone may be an important factor. ET-1 may be indirectly play a role in SAM by cross-talking and potentiating the activities of other vasoconstrictors such as norepinephrine and by orchestrating its reparative phase.
Ammouri, W; Tazi, Z Mezalek; Harmouche, H; Maamar, M; Adnaoui, M
2017-09-02
Hyperhomocysteinemia has been suspected of favoring thrombosis. Several case-control studies and even a meta-analysis have confirmed a link between venous thrombosis and hyperhomocysteinemia. Homocysteine is due to genetic and acquired factors (poor diet in folate and vitamin B12, older age, renal impairment, thyroid diseases, and malignancies) induced by the intake and the concentrations of vitamin B9 or B12 in the majority of cases. We report the cases of four Moroccan patients who presented with acute vein thrombosis of different sites: a 34-year-old man, a 60-year-old man, a 58-year-old man, and a 47-year-old woman. All patients had a low level of cobalamin with marked hyperhomocysteinemia with normal serum and red cell folic acid. Venous thrombosis revealed pernicious anemia in all patients. Their low levels of cobalamin, atrophic gastritis, and positive results for gastric parietal cell antibodies confirmed the diagnosis of pernicious anemia. There was no evidence of immobilization, recent surgery, malignancy, antiphospholipid antibody, myeloproliferative disorder, or hormone replacement therapy. No deficiencies in protein C and protein S were detected; they had normal antithrombin III function and factor V Leiden; no prothrombin gene mutations were detected. Treatment included orally administered anticoagulation therapy and cobalamin supplementation. The outcome was favorable in all cases. These reports demonstrate that pernicious anemia, on its own, can lead to hyperhomocysteinemia that is significant enough to lead to thrombosis. Understanding the molecular pathogenesis of the development of thrombosis in patients with hyperhomocysteinemia related to Biermer disease would help us to identify patients at risk and to treat them accordingly. The literature concerning the relationship between homocysteine and venous thrombosis is briefly reviewed.
Ottens, Jane; Baker, Robert A; Sanderson, Andrew J; Newland, Richard F
2010-06-01
The use of surface modified, biocompatible tubing in cardiopulmonary bypass has been reported to decrease the inflammatory responses caused by blood contact with the non endothelial surface of poly vinyl chloride (PVC) tubing. The combination of advances in biocompatible tubing and increased affordability resulted in a change to our cardiopulmonary bypass circuit, with the Terumo Capiox SX25 oxygenator and Cobe PVC tubing being replaced with a Terumo Capiox SX25RX (with X coating) and Cobe SMARxT tubing. Prior to the introduction of the coated oxygenator, no connection problems had been evident. One unrelated disconnection involving coated tubing was reported in June 2005 to the Australian and New Zealand College of Perfusionists Perfusion Incident Reporting System. At this time we revised all of our set up protocols and the recommended actions from manufacturers. We further report three separate incidents of pump boot disconnection from the venous reservoir outlet of the oxygenator during bypass (that occurred within a 13-month period), and an outline of immediate and prospective evaluation of the probable cause. We propose that SMARxT 3/8" x 3/32" tubing should not be used on the venous outlet connector of Terumo Capiox SX25RX oxygenators. It appears as though the design of the outlet combined with the properties of SMARxT tubing may contribute to the disconnection.
A new method for noninvasive venous blood oxygen detection.
Zhang, Xu; Zhang, Meimei; Zheng, Shengkun; Wang, Liqi; Ye, Jilun
2016-07-19
Blood oxygen saturation of vein (SvO2) is an important clinical parameter for patient monitoring. However, the existing clinical methods are invasive, expensive, which are also painful for patients. Based on light-absorption, this study describes a new noninvasive SvO2 measurement method by using external stimulation signal to generate cyclical fluctuation signal in the vein, which overcomes the low signal-to-noise ratio problem in the measurement process. In this way, the value of SvO2 can be obtained continuously in real time. The experimental results demonstrate that the method can successfully measure venous oxygen saturation by artificial addition of stimulation. Under hypoxic conditions, the system can reflect the overall decline of venous oxygen saturation better. When the results measured by the new method are compared with those measured by the invasive method, the root mean square error of the difference is 5.31 and the correlation coefficient of the difference is 0.72. The new method can be used to measure SvO2 and evaluate body oxygen consumption, and its accuracy needs improvement. Real-time and continuous monitoring can be achieved by replacing invasive method with noninvasive method, which provides more comprehensive clinical information in a timely manner and better meet the needs of clinical treatment. However, the accuracy of the new noninvasive SvO2 measurement based on light-absorption has to be further improved.
Management of rivaroxaban in relation to bodyweight and body mass index
Uprichard, James
2016-01-01
Being overweight or obese is associated with a higher individual risk of venous thromboembolism and poorer postprocedural outcomes after hip or knee replacement surgery. In addition, there is evidence that obesity represents a significant driving factor for the current and projected prevalence of atrial fibrillation. Rivaroxaban and other direct oral anticoagulants offer fixed-dose regimens for these indications. They do not require therapeutic drug monitoring or dose adjustment according to the weight of the patient. However, primary care physicians seem to be hesitant to accept the concept of a fixed-dose regimen for patients at extremes of weight, perhaps because of familiarity with weight-based dosing of other drugs including low molecular weight heparins. The main concerns related to unadjusted dosing are increased exposure in underweight patients leading to a risk of excessive bleeding and conversely to underanticoagulation of overweight patients. Rivaroxaban has shown similar efficacy and a similar or better safety profile compared with standard treatment for several venous and arterial indications, including venous thromboembolism, nonvalvular atrial fibrillation, and acute coronary syndrome. Prespecified subgroup analyses of patients stratified by weight or body mass index demonstrated outcomes that were consistent with the overall analysis and within each weight and body mass index group. The results suggest that standard-dose rivaroxaban can be safely prescribed in adult patients of all weights. PMID:27090286
NASA Technical Reports Server (NTRS)
Katkov, V. Y.; Chesturkhin, V. V.; Zybin, O. K.; Sukhotskiy, S. S.; Abrosimov, S. V.; Utkin, V. N.
1981-01-01
The right parts of the heart and the radial artery were catheterized in healthy male volunteers before and 5 days after strict bedrest in antiorthostatic position of the body (-4.5 deg). After immobilization, most values of central circulation showed no essential changes; the only exceptions were indicates characterizing the inotropic myocardial condition. A shift in the direction of acidosis of a mixed character was noted in mixed venous blood, the beta lipoprotein content increased. A decrease in the arteriovenous difference in oxygen was encountered in blood draining from the heart (from the coronary sinus).
The effect on slurry water as a fresh water replacement in concrete properties
NASA Astrophysics Data System (ADS)
Kadir, Aeslina Abdul; Shahidan, Shahiron; Hai Yee, Lau; Ikhmal Haqeem Hassan, Mohd; Bakri Abdullah, Mohd Mustafa Al
2016-06-01
Concrete is the most widely used engineering material in the world and one of the largest water consuming industries. Consequently, the concrete manufacturer, ready mixed concrete plant is increased dramatically due to high demand from urban development project. At the same time, slurry water was generated and leading to environmental problems. Thus, this paper is to investigate the effect of using slurry water on concrete properties in term of mechanical properties. The basic wastewater characterization was investigated according to USEPA (Method 150.1 & 300.0) while the mechanical property of concrete with slurry water was compared according to ASTM C1602 and BS EN 1008 standards. In this research, the compressive strength, modulus of elasticity and tensile strength were studied. The percentage of wastewater replaced in concrete mixing was ranging from 0% up to 50%. In addition, the resulted also suggested that the concrete with 20% replacement of slurry water was achieved the highest compressive strength and modulus of elasticity compared to other percentages. Moreover, the results also recommended that concrete with slurry water mix have better compressive strength compared to control mix concrete.
Properties of Non-Structural Concrete Made with Mixed Recycled Aggregates and Low Cement Content
López-Uceda, Antonio; Ayuso, Jesús; López, Martin; Jimenez, José Ramón; Agrela, Francisco; Sierra, María José
2016-01-01
In spite of not being legally accepted in most countries, mixed recycled aggregates (MRA) could be a suitable raw material for concrete manufacturing. The aims of this research were as follows: (i) to analyze the effect of the replacement ratio of natural coarse aggregates with MRA, the amount of ceramic particles in MRA, and the amount of cement, on the mechanical and physical properties of a non-structural concrete made with a low cement content; and (ii) to verify if it is possible to achieve a low-strength concrete that replaces a greater amount of natural aggregate with MRA and that has a low cement content. Two series of concrete mixes were manufactured using 180 and 200 kg/m3 of CEM II/A-V 42.5 R type Portland cement. Each series included seven concrete mixes: one with natural aggregates; two MRA with different ceramic particle contents; and one for each coarse aggregate replacement ratio (20%, 40%, and 100%). To study their properties, compressive and splitting tensile strength, modulus of elasticity, density, porosity, water penetration, and sorptivity, tests were performed. The results confirmed that the main factors affecting the properties analyzed in this research are the amount of cement and the replacement ratio; the two MRAs used in this work presented a similar influence on the properties. A non-structural, low-strength concrete (15 MPa) with an MRA replacement ratio of up to 100% for 200 kg/m3 of cement was obtained. This type of concrete could be applied in the construction of ditches, sidewalks, and other similar civil works. PMID:28787874
Properties of Non-Structural Concrete Made with Mixed Recycled Aggregates and Low Cement Content.
López-Uceda, Antonio; Ayuso, Jesús; López, Martin; Jimenez, José Ramón; Agrela, Francisco; Sierra, María José
2016-01-26
In spite of not being legally accepted in most countries, mixed recycled aggregates (MRA) could be a suitable raw material for concrete manufacturing. The aims of this research were as follows: (i) to analyze the effect of the replacement ratio of natural coarse aggregates with MRA, the amount of ceramic particles in MRA, and the amount of cement, on the mechanical and physical properties of a non-structural concrete made with a low cement content; and (ii) to verify if it is possible to achieve a low-strength concrete that replaces a greater amount of natural aggregate with MRA and that has a low cement content. Two series of concrete mixes were manufactured using 180 and 200 kg/m³ of CEM II/A-V 42.5 R type Portland cement. Each series included seven concrete mixes: one with natural aggregates; two MRA with different ceramic particle contents; and one for each coarse aggregate replacement ratio (20%, 40%, and 100%). To study their properties, compressive and splitting tensile strength, modulus of elasticity, density, porosity, water penetration, and sorptivity, tests were performed. The results confirmed that the main factors affecting the properties analyzed in this research are the amount of cement and the replacement ratio; the two MRAs used in this work presented a similar influence on the properties. A non-structural, low-strength concrete (15 MPa) with an MRA replacement ratio of up to 100% for 200 kg/m³ of cement was obtained. This type of concrete could be applied in the construction of ditches, sidewalks, and other similar civil works.
2011-01-01
Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of advice about self-help interventions in people receiving usual care for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2011 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 101 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri-ulcer injection of granulocyte-macrophage colony-stimulating factor, self-help (advice to elevate leg, to keep leg active, to modify diet, to stop smoking, to reduce weight), short-stretch bandages, single-layer non-elastic system, skin grafting, superficial vein surgery, systemic mesoglycan, therapeutic ultrasound, and topical treatments (antimicrobial agents, autologous platelet lysate, calcitonin gene-related peptide plus vasoactive intestinal polypeptide, freeze-dried keratinocyte lysate, mesoglycan, negative pressure, recombinant keratinocyte growth factor, platelet-derived growth factor). PMID:22189344
Measurement of Thrombus Flux Using Transesophageal Echocardiography
NASA Astrophysics Data System (ADS)
Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya, Hiroyuki
2006-05-01
Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the FSET to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed.
Properties of concrete modified with waste Low Density Polyethylene and saw dust ash
NASA Astrophysics Data System (ADS)
Srimanikandan, P.; Sreenath, S.
2017-07-01
The increase in industrialization creates need for disposal of large quantity of by-products. To overcome the difficulty of disposal, these by-products can be used as a replacement for raw material. In this concern, non-conventional industrial wastes such as plastic bags, PET bottles, pulverized waste Low Density Polyethylene (LDPE) and biological waste such as saw-dust ash, coconut coir were used as a replacement in concrete. In this project, saw-dust ash and pulverized waste LDPE were introduced as the partial replacement for cement and fine aggregates respectively. 0%, 5%, 10%, 15% and 20% of sand by volume was replaced with LDPE and 0%, 1%, 3%, 5% and 10% of cement by volume was replaced with saw dust ash. Standard cube, cylinder and prism specimens were cast to assess the compressive strength, split tensile strength and flexural strength of modified concrete after 28 days of curing. Optimum percentage of replacement was found by comparing the test results. The mix with 5% of LDPE and 3% of saw dust ash showed a better result among the other mixes.
Kapoor, A; Ellis, A; Shaffer, N; Gurwitz, J; Chandramohan, A; Saulino, J; Ishak, A; Okubanjo, T; Michota, F; Hylek, E; Trikalinos, T A
2017-02-01
Essentials Despite trial data, guidelines have not endorsed direct oral Xa inhibitors above other options. We provide profiles of venous thromboembolism and hemorrhage risk for 12 options. Direct oral Xa inhibitors had a favorable profile compared with low-molecular-weight heparin. Other options did not have favorable profiles compared with low-molecular-weight heparin. Background There are numerous trials and several meta-analyses comparing venous thromboembolism (VTE) prophylaxis options after total hip and knee replacement (THR and TKR). None have included simultaneous comparison of new with older options. Objective To measure simultaneously the relative risk of VTE and hemorrhage for 12 prophylaxis options. Methods We abstracted VTE and hemorrhage information from randomized controlled trials published between January 1990 and June 2016 comparing 12 prophylaxis options. We then constructed networks to compute the relative risk for each option, relative to once-daily dosing with low-molecular-weight heparin (LMWH) Low. Results Main: Relative to LMWH Low, direct oral Xa inhibitors had the lowest risk of total deep vein thrombosis (DVT)-asymptomatic and symptomatic- (odds ratio [OR], 0.45; 95% confidence interval [CI], 0.35-0.57), translating to 53-139 fewer DVTs per 1000 patients. Vitamin K antagonists (VKAs) titrated to International Normalized Ratio [INR] 2-3 predicted 56% more DVT events (OR, 1.56; 95% CI, 1.14-2.14). Aspirin performed similarly (OR, 0.80; 95% CI, 0.34-1.86), although small numbers prohibit firm conclusions. Direct oral Xa inhibitors did not lead to significantly more bleeding (OR, 1.21; 95% CI, 0.79-1.90). Secondary: Relative to LMWH Low, direct oral Xa inhibitors prevented 4-fold more symptomatic DVTs (OR, 0.25; 95% CI, 0.13-0.47). Conclusions Relative to LMWH Low, direct oral Xa inhibitors had a more favorable profile of VTE and hemorrhage risk, whereas VKAs had a less favorable profile. The profile of other agents was not more or less favorable. Clinicians should consider these profiles when selecting prophylaxis options. © 2016 International Society on Thrombosis and Haemostasis.
An Eye Oximeter for Combat Casualty Care
1999-01-01
concentration. Here a procedure is de- struments such as fingertip pulse oximeters and fi- scribed that allows for the calculation of optimum beroptic...of a neonate due to a pulse oximeter : 20. Trouwborst A. Tenbrinck R, van Woerkens E. Blood gas arterial saturation monitoring. Pediatrics. 1992;89:154...analysis of mixed venous blood during normoxic acute 29. Severinghaus JW, Spellman MJ. Pulse oximeter failure isovolemic hemodilution in pigs. Anesth
Clinical application of the pO(2)-pCO(2) diagram.
Paulev, P-E; Siggaard-Andersen, O
2004-10-01
Based on the classic, linear blood gas diagram a logarithmic blood gas map was constructed. The scales were extended by the use of logarithmic axes in order to allow for high patient values. Patients with lung disorders often have high arterial carbon dioxide tensions, and patients on supplementary oxygen typically respond with high oxygen tensions off the scale of the classic diagram. Two case histories illustrate the clinical application of the logarithmic blood gas map. Variables from the two patients were measured by the use of blood gas analysis equipment. Measured and calculated values are tabulated. The calculations were performed using the oxygen status algorithm. When interpreting the graph for a given patient it is recommended first to observe the location of the marker for the partial pressure of oxygen in inspired, humidified air (I) to see whether the patient is breathing atmospheric air or air with supplementary oxygen. Then observe the location of the arterial point (a) to see whether hypoxemia or hypercapnia appears to be the primary disturbance. Finally observe the alveolo-arterial oxygen tension difference to estimate the degree of veno-arterial shunting. If the mixed venous point (v) is available, then observe the value of the mixed venous oxygen tension. This is the most important indicator of global tissue hypoxia.
Impact of sildenafil on survival of patients with idiopathic pulmonary arterial hypertension.
Zeng, Wei-Jie; Sun, Yun-Juan; Gu, Qing; Xiong, Chang-Ming; Li, Jian-Jun; He, Jian-Guo
2012-09-01
It has been reported that short-term sildenafil therapy is safe and effective for patients with pulmonary arterial hypertension. However, data regarding the impact of sildenafil on the survival of patients with idiopathic pulmonary arterial hypertension remain limited. The study was conducted on 77 patients with newly diagnosed idiopathic pulmonary arterial hypertension at Fu Wai Hospital between September 2005 and September 2009. Patients were divided into 2 groups: the sildenafil group and the conventional group. Nine patients treated with sildenafil were re-evaluated by right heart catheterization after 3 months. Our data demonstrated that the 6-minute walk distance, World Health Organization functional class, mixed venous oxygen saturation, and hemodynamics significantly improved after 3 months of sildenafil therapy (P < .05). The baseline characteristics of the sildenafil group were similar to those of the conventional group. The 1-, 2-, and 3-year survival rates in the sildenafil group were 88%, 72%, and 68% compared with 61%, 36%, and 27% in the conventional group (P < .001). The absence of sildenafil therapy, lower body mass index, and lower mixed venous oxygen saturation were found to be independent predictors of mortality. In conclusion, sildenafil therapy was found to be associated with improved survival in patients with idiopathic pulmonary arterial hypertension.
Swift, Andrew J; Rajaram, Smitha; Campbell, Michael J; Hurdman, Judith; Thomas, Steve; Capener, Dave; Elliot, Charlie; Condliffe, Robin; Wild, Jim M; Kiely, David G
2014-01-01
There are limited data on the prognostic value of cardiovascular magnetic resonance measurements in idiopathic pulmonary arterial hypertension, with no studies investigating the impact of correction of cardiovascular magnetic resonance indices for age and sex on prognostic value. Consecutive patients with idiopathic pulmonary arterial hypertension underwent cardiovascular magnetic resonance imaging at 1.5T. Steady-state free precession cardiac volumes and mass measurements were corrected for age, sex, and body surface area according to reference data and prognostic significance assessed. A total of 80 patients with idiopathic pulmonary arterial hypertension were identified, and 23 patients died during the mean follow-up of 32±14 months. Corrected for age, sex, and body surface area, right ventricular end-systolic volume (P=0.004) strongly predicted mortality, independent of World Health Organization functional class, mean right atrial pressure, cardiac index, and mixed venous oxygen saturations. Consideration should be given to correcting cardiovascular magnetic resonance measures for age, sex, and body surface area, particularly given the changing demographics of patients with idiopathic pulmonary arterial hypertension. Corrected right ventricular end-systolic volume is a strong prognostic marker in idiopathic pulmonary arterial hypertension, independent of invasively derived measurements, mean right atrial pressure cardiac index, and mixed venous oxygen saturations.
Study on Strength and Durability Characteristics of Concrete with Ternary Blend
NASA Astrophysics Data System (ADS)
Nissi Joy, C.; Ramakrishnan, K.; Snega, M.; Ramasundram, S.; Venkatasubramanian, C.; Muthu, D.
2017-07-01
In the present scenario to fulfill the demands of sustainable construction, concrete made with multi-blended cement system of Ordinary Portland Cement (OPC) and different mineral admixtures is the wise choice for the construction industry. In this research work, M20 grade mix of concrete (with water - binder ratio as 0.48) is adopted with glass powder (GP) and Sugar Cane Bagasse Ash (SCBA) as partial replacement of cement. GP is an inert material, they occupy the landfill space for considerable amount of time unless there is a potential for recycling. Such glass wastes in the crushed form have a good potential in the infrastructure industry. Replacement of cement by GP from 30% to 0% by weight of cement in step of 5% and by SCBA from 0% to 30% in step of 5% respectively was adopted. In total, seven different combinations of mixes were studied at two different ages of concrete namely 7 and 28 days. Compressive strength of cubes for various percentage of replacement were investigated and compared with conventional concrete to find out the maximum mix ratio. Flexural strength of concrete for the maximum mix ratio was found out and durability parameters viz., water absorption and sorptivity were studied. From the experimental study, 20% SCBA and 10% GP combination was found to be the maximum mix ratio.
Utilization of fly ash as partial sand replacement in oil palm shell lightweight aggregate concrete
NASA Astrophysics Data System (ADS)
Nazrin Akmal, A. Z. Muhammad; Muthusamy, K.; Mat Yahaya, F.; Hanafi, H. Mohd; Nur Azzimah, Z.
2017-11-01
Realization on the increasing demand for river sand supply in construction sector has inspired the current research to find alternative material to reduce the use of natural sand in oil palm shell lightweight aggregate concrete (OPS LWAC) production. The existence of fly ash, a by-product generated from coal power plant, which pose negative impact to the environment when it is disposed as waste, were used in this research. The effect of fly ash content as partial sand replacement towards workability and compressive strength of OPS lightweight aggregate concrete were investigated. Four concrete mixes containing various percentage of fly ash that are 0%, 10%, 20% and 30% by weight of sand were used in the experimental work. All mixes were cast in form of cubes before subjected to water curing until the testing age. Compressive strength test were conducted at 1, 3, 7 and 28 days. The finding shows that the workability of the OPS LWAC decreases when more fly ash are used as sand replacement. It was found that adding of 10% fly ash as sand replacement content resulted in better compressive strength of OPS LWAC, which is higher than the control mix.
Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers.
Bickler, Philip E; Feiner, John R; Rollins, Mark D
2013-10-01
Cerebral oximetry is a noninvasive optical technology that measures frontal cortex blood hemoglobin-oxygen saturation. Commercially available cerebral oximeters have not been evaluated independently. Unlike pulse oximeters, there are currently no Food and Drug Administration standards for performance or accuracy. We tested the hypothesis that cerebral oximeters accurately measure a fixed ratio of the oxygen saturation in cerebral mixed venous and arterial blood. We evaluated the performance of 5 commercially available cerebral oximeters: the EQUANOX® 7600 in 3- and 4-wavelength versions (Nonin Medical, Plymouth, MN), FORE-SIGHT® (Casmed, Branford, CT), INVOS® 5100C (Covidien, Boulder, CO), and the NIRO-200NX® (Hamamatsu Photonics, Hamamatsu City, Japan) during stable isocapnic hypoxia in volunteers. Twenty-three healthy adults (14 men, 9 women) had sensors placed on each side of the forehead. The subject's inspired oxygen (FIO2) was then changed to produce 6 steady-state arterial oxygen saturation (SaO2) levels between 100% and 70%, while end-tidal CO2 was maintained constant. At each plateau, simultaneous blood samples from the jugular bulb and radial artery were analyzed with a hemoximeter (OSM-3, Radiometer Medical A/S, Copenhagen, Denmark). Each cerebral oximeter's bias was calculated as the difference between the instrument's reading (cerebral saturation, ScO2) with the weighted saturation of venous and arterial blood (Sa/vO2), as specified by each manufacturer (INVOS: 25% arterial/75% venous; FORE-SIGHT, EQUANOX, and NIRO: 30% arterial/70% venous). Five hundred forty-two comparisons between paired blood samples and oximeter readings were analyzed. The pooled root mean square error was 8.06%, a value higher than for pulse oximeters, which is ±3% by Food and Drug Administration standards. The mean % bias ± SD (precision) and root mean square errors were: FORE-SIGHT 1.76 ± 3.92 and 4.28; INVOS 0.05 ± 9.72 and 9.69; NIRO-200NX -1.13 ± 9.64 and 9.68; EQUANOX-3 λ 2.48 ± 8.12 and 8.47; EQUANOX-4 λ 2.84 ± 6.27 and 6.86. The FORE-SIGHT, NIRO-200NX, and EQUANOX-3 λ had significantly more positive bias at lower SaO2. The amount of bias during hypoxia was reduced when the bias was calculated on the basis of difference between oximeter reading and the arterial and mixed venous saturation difference rather than the weighted average of blood saturation, indicating that differences in the ratio between arterial and venous blood volumes account for some of the positive bias at low saturation. Dark skin pigment tended to produce more negative bias in all instruments but bias was significantly larger than zero only for the FORE-SIGHT oximeter. Bias was significantly more negative in women for INVOS and EQUANOX devices but not for the FORE-SIGHT device. While responsive to desaturation, cerebral oximeters exhibited large variation in reading errors between subjects, with mean bias possibly related to variations in the ratio of arterial and venous blood in the sampling area of the brain. This ratio is probably not fixed, as assumed by the manufacturers, but dynamically changes with hypoxia. Better understanding these factors could improve the performance of cerebral oximeters and help establish saturation or blood flow thresholds for brain well-being.
2008-01-01
Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2007 (BMJ Clinical Evidence reviews are updated periodically, please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 80 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids, pentoxifylline, rutosides, stanozolol, sulodexide, thromboxane alpha2 antagonists, zinc), peri-ulcer injection of granulocyte-macrophage colony-stimulating factor, short-stretch bandages, single-layer non-elastic system, skin grafting, superficial vein surgery, systemic mesoglycan, therapeutic ultrasound, self-help (advice to elevate leg, advice to keep leg active, advice to modify diet, advice to stop smoking, advice to reduce weight), and topical treatments (antimicrobial agents, autologous platelet lysate, calcitonin gene-related peptide plus vasoactive intestinal polypeptide, freeze-dried keratinocyte lysate, mesoglycan, negative-pressure recombinant keratinocyte growth factor, platelet-derived growth factor). PMID:19445798
Hahn, Andreas; Nics, Lukas; Baldinger, Pia; Ungersböck, Johanna; Dolliner, Peter; Frey, Richard; Birkfellner, Wolfgang; Mitterhauser, Markus; Wadsak, Wolfgang; Karanikas, Georgios; Kasper, Siegfried; Lanzenberger, Rupert
2012-08-01
image- derived input functions (IDIFs) represent a promising technique for a simpler and less invasive quantification of PET studies as compared to arterial cannulation. However, a number of limitations complicate the routine use of IDIFs in clinical research protocols and the full substitution of manual arterial samples by venous ones has hardly been evaluated. This study aims for a direct validation of IDIFs and venous data for the quantification of serotonin-1A receptor binding (5-HT(1A)) with [carbonyl-(11)C]WAY-100635 before and after hormone treatment. Fifteen PET measurements with arterial and venous blood sampling were obtained from 10 healthy women, 8 scans before and 7 after eight weeks of hormone replacement therapy. Image-derived input functions were derived automatically from cerebral blood vessels, corrected for partial volume effects and combined with venous manual samples from 10 min onward (IDIF+VIF). Corrections for plasma/whole-blood ratio and metabolites were done separately with arterial and venous samples. 5-HT(1A) receptor quantification was achieved with arterial input functions (AIF) and IDIF+VIF using a two-tissue compartment model. Comparison between arterial and venous manual blood samples yielded excellent reproducibility. Variability (VAR) was less than 10% for whole-blood activity (p>0.4) and below 2% for plasma to whole-blood ratios (p>0.4). Variability was slightly higher for parent fractions (VARmax=24% at 5 min, p<0.05 and VAR<13% after 20 min, p>0.1) but still within previously reported values. IDIFs after partial volume correction had peak values comparable to AIFs (mean difference Δ=-7.6 ± 16.9 kBq/ml, p>0.1), whereas AIFs exhibited a delay (Δ=4 ± 6.4s, p<0.05) and higher peak width (Δ=15.9 ± 5.2s, p<0.001). Linear regression analysis showed strong agreement for 5-HT(1A) binding as obtained with AIF and IDIF+VIF at baseline (R(2)=0.95), after treatment (R(2)=0.93) and when pooling all scans (R(2)=0.93), with slopes and intercepts in the range of 0.97 to 1.07 and -0.05 to 0.16, respectively. In addition to the region of interest analysis, the approach yielded virtually identical results for voxel-wise quantification as compared to the AIF. Despite the fast metabolism of the radioligand, manual arterial blood samples can be substituted by venous ones for parent fractions and plasma to whole-blood ratios. Moreover, the combination of image-derived and venous input functions provides a reliable quantification of 5-HT(1A) receptors. This holds true for 5-HT(1A) binding estimates before and after treatment for both regions of interest-based and voxel-wise modeling. Taken together, the approach provides less invasive receptor quantification by full independence of arterial cannulation. This offers great potential for the routine use in clinical research protocols and encourages further investigation for other radioligands with different kinetic characteristics. Copyright © 2012 Elsevier Inc. All rights reserved.
Ronen, Ohad; Shlomo, Fanny; Ben-Adiva, Gila; Edri, Zehava; Shema-Didi, Lilach
2017-10-01
The use of intravascular catheters is often complicated by phlebitis, which is associated with increased morbidity and extended duration of hospitalization. We conducted a study to investigate the impact of needleless intravenous access devices on the rate of phlebitis in peripheral venous catheters (PVCs). We prospectively recruited patients in 2 phases. The first group was treated with a regular cap, and the second group was treated with a needleless connector. The incidence of catheter-related phlebitis (CRP) was recorded as the primary end point. A total of 620 PVCs using regular caps were inserted into 340 patients and CRP rates were recorded. In the second phase of the study, 169 PVCs using needleless connectors were inserted into 135 patients. In the group treated with the regular cap, the CRP rate was 60% compared with 7% in the group treated with the needleless cap (P <.001). Consequently, the number of catheter replacements was decreased from 1.9 on average to 1.3 (P <.001). In both phases, patients who developed phlebitis had a statistically significant longer mean hospitalization period (P <.001), as were patients in the regular cap group (P <.01). The use of needleless connectors was found to be associated with a significant reduction of CRP in peripheral veins in a surgery department setting. The decreased morbidity resulted in a lower number of catheter replacements and duration of hospitalization. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
[Clinical study on patellar replacement in total knee arthroplasty].
Bao, Liang; Gao, Zhihui; Shi, Xiaoqiang; Fang, Xiaomin; Jin, Qunhua
2013-01-01
To evaluate the influence of patellar replacement on total knee arthroplasty by comparing with non patellar replacement. Between September 2010 and November 2010, 63 patients (63 knees) with osteoarthritis who met the selection criteria and underwent total knee arthroplasty, were randomly divided into 2 groups: patellar replacement in 32 cases (replacement group), non patellar replacement in 31 cases (non patellar replacement group). There was no significant difference in gender, age, disease duration, osteoarthritis grading, the clinical and functional scores of American Knee Society Score (KSS), the patellar tilt angle, tibiofemoral angle, and patellar ligament ratio between 2 groups (P > 0.05), they were comparable. After 6 weeks, 3, 6, and 12 months of operation, clinical and imaging evaluation methods were used to assessment the effectiveness. Primary healing of incision was obtained in all patients of 2 groups. Deep venous thrombosis occurred in 6 cases of replacement group and in 8 cases of non patellar replacement group. All patients were followed up 12 months. The postoperative incidence of anterior knee pain in replacement group was significantly lower than that in non patellar replacement group (P < 0.05) at 3, 6, and 12 months after operation. No significant difference was found in the postoperative KSS clinical score between 2 groups at each time point (P > 0.05). The joint function score of the replacement group was significantly higher than that of the non patellar replacement group at the other time point (P < 0.05) except the score at 6 weeks and 3 months. Significant difference was found in the patella score between 2 groups at 12 months (P < 0.05), but no significant difference at the other time points (P > 0.05). X-ray film showed no patellar fracture and dislocation, or loosening and breakage of internal fixation. At 12 months after operation, the tibiofemoral angle, the patellar ligament ratio, and the patellar tilt angle showed no significant difference between 2 groups (P > 0.05). Patella replacement can improve knee function score and the patella score, and reduce the incidence of postoperative anterior knee pain.
Ashby, Rebecca L; Gabe, Rhian; Ali, Shehzad; Saramago, Pedro; Chuang, Ling-Hsiang; Adderley, Una; Bland, J Martin; Cullum, Nicky A; Dumville, Jo C; Iglesias, Cynthia P; Kang'ombe, Arthur R; Soares, Marta O; Stubbs, Nikki C; Torgerson, David J
2014-09-01
Compression is an effective and recommended treatment for venous leg ulcers. Although the four-layer bandage (4LB) is regarded as the gold standard compression system, it is recognised that the amount of compression delivered might be compromised by poor application technique. Also the bulky nature of the bandages might reduce ankle or leg mobility and make the wearing of shoes difficult. Two-layer compression hosiery systems are now available for the treatment of venous leg ulcers. Two-layer hosiery (HH) may be advantageous, as it has reduced bulk, which might enhance ankle or leg mobility and patient adherence. Some patients can also remove and reapply two-layer hosiery, which may encourage self-management and could reduce costs. However, little robust evidence exists about the effectiveness of two-layer hosiery for ulcer healing and no previous trials have compared two-layer hosiery delivering 'high' compression with the 4LB. Part I To compare the clinical effectiveness and cost-effectiveness of HH and 4LB in terms of time to complete healing of venous leg ulcers. Part II To synthesise the relative effectiveness evidence (for ulcer healing) of high-compression treatments for venous leg ulcers using a mixed-treatment comparison (MTC). Part III To construct a decision-analytic model to assess the cost-effectiveness of high-compression treatments for venous leg ulcers. Part I A multicentred, pragmatic, two-arm, parallel, open randomised controlled trial (RCT) with an economic evaluation. Part II MTC using all relevant RCT data - including Venous leg Ulcer Study IV (VenUS IV). Part III A decision-analytic Markov model. Part I Community nurse teams or services, general practitioner practices, leg ulcer clinics, tissue viability clinics or services and wound clinics within England and Northern Ireland. Part I Patients aged ≥ 18 years with a venous leg ulcer, who were willing and able to tolerate high compression. Part I Participants in the intervention group received HH. The control group received the 4LB, which was applied according to standard practice. Both treatments are designed to deliver 40 mmHg of compression at the ankle. Part II and III All relevant high-compression treatments including HH, the 4LB and the two-layer bandage (2LB). Part I The primary outcome measure was time to healing of the reference ulcer (blinded assessment). Part II Time to ulcer healing. Part III Quality-adjusted life-years (QALYs) and costs. Part I A total of 457 participants were recruited. There was no evidence of a difference in time to healing of the reference ulcer between groups in an adjusted analysis [hazard ratio (HR) 0.99, 95% confidence interval (CI) 0.79 to 1.25; p = 0.96]. Time to ulcer recurrence was significantly shorter in the 4LB group (HR = 0.56, 95% CI 0.33 to 0.94; p = 0.026). In terms of cost-effectiveness, using QALYs as the measure of benefit, HH had a > 95% probability of being the most cost-effective treatment based on the within-trial analysis. Part II The MTC suggests that the 2LB has the highest probability of ulcer healing compared with other high-compression treatments. However, this evidence is categorised as low to very low quality. Part III Results suggested that the 2LB had the highest probability of being the most cost-effective high-compression treatment for venous leg ulcers. Trial data from VenUS IV found no evidence of a difference in venous ulcer healing between HH and the 4LB. HH may reduce ulcer recurrence rates compared with the 4LB and be a cost-effective treatment. When all available high-compression treatments were considered, the 2LB had the highest probability of being clinically effective and cost-effective. However, the underpinning evidence was sparse and more research is needed. Further research should thus focus on establishing, in a high-quality trial, the effectiveness of this compression system in particular. Current Controlled Trials ISRCTN49373072. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 18, No. 57. See the NIHR Journals Library website for further project information.
Chukwukaelo, A K; Aladi, N O; Okeudo, N J; Obikaonu, H O; Ogbuewu, I P; Okoli, I C
2018-03-01
Performance and meat quality characteristics of broilers fed fermented mixture of grated cassava roots and palm kernel cake (FCP-mix) as a replacement for maize were studied. One hundred and eighty (180), 7-day-old broiler chickens were divided into six groups of 30 birds, and each group replicated thrice. Six experimental diets were formulated for both starter and finisher stages with diets 1 and 6 as controls. Diet 1 contained maize whereas diet 6 contained a 1:1 mixture of cassava root meal (CRM) and palm kernel cake (PKC). In diets 2, 3, 4, and 5, the FCP-mix replaced maize at the rate of 25, 50, 75, and 100%, respectively. Each group was assigned to one experimental diet in a completely randomized design. The proximate compositions of the diets were evaluated. Live weight, feed intake, feed conversion ratio (FCR), carcass weight, and sensory attributes of the meats were obtained from each replicate and data obtained was analyzed statistically. The results showed that live weight, average daily weight gain (ADWG), average daily feed intake (ADFI), and FCR of birds on treatment diets were better than those on the control diets (Diets 1 and 6). The feed cost per kilogram weight gained decreased with inclusion levels of FCP-mix. Birds on diet 1 recorded significantly (p < 0.05) higher dressing percentage than those on the other five treatments. The sensory attributes of the chicken meats were not significantly (p > 0.05) affected by the inclusion of FCP-mix in the diets. FCP-mix is a suitable substitute for maize in broiler diet at a replacement level of up to 100% for best live weight, carcass weight yield, and meat quality.
Ottens, Jane; Baker, Robert A.; Sanderson, Andrew J.; Newland, Richard F.
2010-01-01
Abstract: The use of surface modified, biocompatible tubing in cardiopulmonary bypass has been reported to decrease the inflammatory responses caused by blood contact with the non endothelial surface of poly vinyl chloride (PVC) tubing. The combination of advances in biocompatible tubing and increased affordability resulted in a change to our cardiopulmonary bypass circuit, with the Terumo Capiox® SX25 oxygenator and Cobe PVC tubing being replaced with a Terumo Capiox® SX25RX (with X coating) and Cobe SMARxT® tubing. Prior to the introduction of the coated oxygenator, no connection problems had been evident. One unrelated disconnection involving coated tubing was reported in June 2005 to the Australian and New Zealand College of Perfusionists Perfusion Incident Reporting System. At this time we revised all of our set up protocols and the recommended actions from manufacturers. We further report three separate incidents of pump boot disconnection from the venous reservoir outlet of the oxygenator during bypass (that occurred within a 13-month period), and an outline of immediate and prospective evaluation of the probable cause. We propose that SMARxT® 3/8″ × 3/32″ tubing should not be used on the venous outlet connector of Terumo Capiox® SX25RX oxygenators. It appears as though the design of the outlet combined with the properties of SMARxT® tubing may contribute to the disconnection. PMID:20648902
Current topics in surgery for isolated total anomalous pulmonary venous connection.
Yoshimura, Naoki; Fukahara, Kazuaki; Yamashita, Akio; Doki, Yoshinori; Takeuchi, Katsunori; Higuma, Tomonori; Senda, Kazutaka; Toge, Masayoshi; Matsuo, Tatsuro; Nagura, Saori; Aoki, Masaya; Sakata, Kimimasa; Obi, Hayato
2014-12-01
Surgical correction of total anomalous pulmonary venous connection (TAPVC) remains a challenge, with reported early mortality rates of up to 20%. In this review article, we describe several topics, including surgery for neonates, diagnoses with multidetector computed tomography (MDCT), and primary sutureless repair. Several studies have reported mortality rates of around 10%, and demonstrated unchanged hospital mortality in neonates, despite improvement of the overall mortality of cohorts including older patients. Previous reports identified a low body weight at the time of the operation, preoperative pulmonary venous obstruction (PVO), and a prolonged cardiopulmonary bypass time as risk factors for hospital mortality. With the development of new technologies, MDCT has become a good diagnostic modality for use in the pre- and post-operative evaluation. MDCT delineates the drainage site of the vertical vein and the atypical vessel into the systemic vein, and it can also evaluate the existence of obstruction in the vertical vein. Following favorable experiences with post-repair PVO, the indications for sutureless repair as a primary operation have been expanded for infants, including those at risk of developing PVO after the repair of TAPVC. Primary sutureless repair has proven especially useful for difficult patient groups, such as those with congenital PVO, infracardiac TAPVC with small pulmonary veins, or mixed-type TAPVC.
New strategies for the treatment of acute venous thromboembolism.
Prandoni, Paolo; Lensing, Anthonie W A; Pesavento, Raffaele
2006-11-01
In recent years, new opportunities have emerged that have the potential to change rapidly the therapeutic scenario of patients with acute venous thromboembolism (VTE). Selected patients with deep vein thrombosis (DVT) can be treated effectively and safely at home with fixed doses of low molecular weight heparins. The prompt administration of compression elastic stockings in addition to anticoagulant drugs in patients with acute DVT has the potential to halve the rate of late postthrombotic sequelae. The long-term use of low molecular weight heparins is likely to be more effective than oral anticoagulants for the secondary prevention of VTE in patients with advanced malignancy. Patients with pulmonary embolism and right ventricular dysfunction might benefit from the early administration of thrombolytic drugs in combination with heparin to a greater extent than from heparin alone. Despite an impressive amount of clinical information on the proper duration of oral anticoagulants in patients with unprovoked VTE, the optimal long-term treatment of these patients remains undefined. Finally, new categories of drugs are emerging that have the potential to replace conventional anticoagulants in the near future. They include compounds that inhibit factor Xa or thrombin.
Cardiovascular responses to hypogravic environments
NASA Technical Reports Server (NTRS)
Sandler, H.
1983-01-01
The cardiovascular deconditioning observed during and after space flight is characterized in a review of human space and simulation studies and animal simulations. The various simulation techniques (horizontal bed rest, head-down tilt, and water immersion in man, and immobilization of animals) are examined, and sample results are presented in graphs. Countermeasures such as exercise regimens, fluid replacement, drugs, venous pooling, G-suits, oscillating beds, electrostimulation of muscles, lower-body negative pressure, body-surface cooling, and hypoxia are reviewed and found to be generally ineffective or unreliable. The need for future space experimentation in both humans and animals is indicated.
Rosário, André Loureiro; Park, Marcelo; Brunialti, Milena Karina; Mendes, Marialice; Rapozo, Marjorie; Fernandes, Denise; Salomão, Reinaldo; Laurindo, Francisco Rafael; Schettino, Guilherme Paula; Azevedo, Luciano Cesar P
2011-12-01
The pathogenetic mechanisms associated to the beneficial effects of mixed venous oxygen saturation (SvO(2))-guided resuscitation during sepsis are unclear. Our purpose was to evaluate the effects of an algorithm of SvO(2)-driven resuscitation including fluids, norepinephrine and dobutamine on hemodynamics, inflammatory response, and cardiovascular oxidative stress during a clinically resembling experimental model of septic shock. Eighteen anesthetized and catheterized pigs (35-45 kg) were submitted to peritonitis by fecal inoculation (0.75 g/kg). After hypotension, antibiotics were administered, and the animals were randomized to two groups: control (n = 9), with hemodynamic support aiming central venous pressure 8 to 12 mmHg, urinary output 0.5 mL/kg per hour, and mean arterial pressure greater than 65 mmHg; and SvO(2) (n = 9), with the goals above, plus SvO(2) greater than 65%. The interventions lasted 12 h, and lactated Ringer's and norepinephrine (both groups) and dobutamine (SvO(2) group) were administered. Inflammatory response was evaluated by plasma concentration of cytokines, neutrophil CD14 expression, oxidant generation, and apoptosis. Oxidative stress was evaluated by plasma and myocardial nitrate concentrations, myocardial and vascular NADP(H) oxidase activity, myocardial glutathione content, and nitrotyrosine expression. Mixed venous oxygen saturation-driven resuscitation was associated with improved systolic index, oxygen delivery, and diuresis. Sepsis induced in both groups a significant increase on IL-6 concentrations and plasma nitrate concentrations and a persistent decrease in neutrophil CD14 expression. Apoptosis rate and neutrophil oxidant generation were not different between groups. Treatment strategies did not significantly modify oxidative stress parameters. Thus, an approach aiming SvO(2) during sepsis improves hemodynamics, without any significant effect on inflammatory response and oxidative stress. The beneficial effects associated with this strategy may be related to other mechanisms.
McLiesh, Paul; Wiechula, Rick
2012-01-01
BACKGROUND: The risk of venous thromboembolism for orthopaedic patients is often high due to the length of surgery, damage from trauma to bone and soft tissues and lengthy periods of immobility or reduced mobility. Although venous thromboembolism occurs mainly in inpatients a significant number of patients develop venous thromboembolism post discharge OBJECTIVES: To synthesise the best available evidence on strategies that effectively reduce post discharge venous thromboembolism in orthopaedic patients. INCLUSION CRITERIA: Patients regardless of age, gender or co-morbidities that have been admitted with an acute orthopaedic injury (unplanned) or a planned orthopaedic surgery/procedure and then followed up after discharge. Only papers describing the incidence and prophylaxis treatment used in non-Asian patients were considered for inclusion. Any interventions of combinations of chemoprophylaxis and/or mechanical prophylaxis to prevent venous thromboembolism incidence extending beyond hospital admission. Outcomes included diagnosis of venous thromboembolism following an orthopaedic admission/surgery for up to 6 months post discharge and the incidence of any significant bleeding or death related to venous thromboembolism or haemorrhage.The review considered any randomised controlled trials; in the absence of RCTs other research designs, such as non-randomised controlled trials and before and after studies, were considered SEARCH STRATEGY: Search strategy considered only papers in English from 2000 to March 2012. METHODOLOGICAL QUALITY: Papers selected for retrieval were assessed using standardised critical appraisal instruments from the Joanna Briggs Institute. DATA COLLECTION: Data was extracted from the studies using the standardised Johanna Briggs Institute data extraction form. DATA SYNTHESIS: Of the included studies none matched methodology, treatment or comparator that allowed meta-analysis. The results were therefore presented in a narrative form and were structured using patient population, then intervention and then analysis of results. RESULTS: 20 articles were included in the systematic review. The overall incidence of post discharge venous thromboembolism in orthopaedic patients is not possible to determine due to the variability in reporting criteria and poor follow-up. Use of Low Molecular Weight Heparins was generally shown to be effective in preventing venous thromboembolism. The new generation Factor Xa inhibitors were shown to improve venous thromboembolism prevention however had a slightly higher risk of bleeding. There was limited high level research presented to allow effective assessment of aspirin and/or mechanical compression devices. CONCLUSIONS: Prevention of post discharge venous thromboembolism is complex due to the number of variables that can influence its occurrence. The risk of post discharge venous thromboembolism varies among different patient populations so consideration must be given to matching the risk for each of those groups with available interventions.For higher risk orthopaedic patient groups such as those with large joint replacements and femoral fractures low molecular weight heparins should be considered and continued where possible post discharge for thirty days however the risk profile for venous thromboembolism and bleeding must be considered for both populations and individuals.Consideration in future research design must be given to factors such as: adequate follow-up time, and standardised criteria to measure the incidence of post discharge venous thromboembolism. • Save items Add to Favorites View more options Similar articles Effectiveness of nurse-led preoperative assessment services for elective surgery: a systematic review. [JBI Libr Syst Rev. 2010] The Effectiveness of Integrated Care Pathways for Adults and Children in Health Care Settings: A Systematic Review. [JBI Libr Syst Rev. 2009] Review The effect of insulin therapy algorithms on blood glucose levels in patients following cardiac surgery: A systematic review. [JBI Database System Rev Implem...] Continuous Subcutaneous Insulin Infusion (CSII) Pumps for Type 1 and Type 2 Adult Diabetic Populations: An Evidence-Based Analysis. [Ont Health Technol Assess Ser....] Review The effectiveness of ayurvedic oil-based nasal instillation (Nasya) medicines in the treatment of facial paralysis (Ardita): a systematic review. [JBI Database System Rev Implem...] See reviews... See all... Cited by 1 PubMed Central article A systematic scoping review on the consequences of stress-related hyperglycaemia. [PLoS One. 2018] Related information Cited in PMC Search details 27820532[uid] Search See more... Recent Activity ClearTurn Off Effectiveness of tight glycemic control in the medical Intensive Care Unit: a sy... PubMed 27820532[uid] (1) PubMed 27820349[uid] (1) PubMed Effectiveness of Tight Glycemic Control in the Medical Intensive Care Unit: A Sy... PubMed
Palm Oil Fuel Ash (POFA) and Eggshell Powder (ESP) as Partial Replacement for Cement in Concrete
NASA Astrophysics Data System (ADS)
Ezdiani Mohamad, Mazizah; Mahmood, Ali A.; Min, Alicia Yik Yee; Nur Nadhira A., R.
2018-03-01
This study is an attempt to partially replace Ordinary Portland cement (OPC) in concrete with palm oil fuel ash (POFA) and eggshell powder (ESP). The mix proportions of POFA and ESP were varied at 10% of cement replacement and compared with OPC concrete as control specimen. The fineness of POFA is characterized by passing through 300 μm sieve and ESP by passing through 75 μm sieve. Compressive strength testing was conducted on concrete specimens to determine the optimum mix proportion of POFA and ESP. Generally the compressive strength of OPC concrete is higher compared to POFA-ESP concrete. Based on the results of POFA-ESP concrete overall, it shows that the optimum mix proportion of concrete is 6%POFA:4% ESP achieved compressive strength of 38.60 N/mm2 at 28 days. The compressive strength of OPC concrete for the same period was 42.37 N/mm2. Higher water demand in concrete is needed due to low fineness of POFA that contributing to low compressive strength of POFA-ESP concrete. However, the compressive strength and workability of the POFA-ESP concrete were within the ranges typically encountered in regular concrete mixtures indicating the viability of this replacement procedure for structural and non-structural applications.
Lecerf, J M; Clerc, E; Jaruga, A; Wagner, A; Respondek, F
2015-01-01
The present studies aimed to evaluate the glycaemic and insulinaemic responses, in healthy adults, to short-chain fructo-oligosaccharides (scFOS) from sucrose used to replace sugars in foods. Two study populations aged 18-50 years were recruited and they consumed dairy desserts or pound cakes containing either standard sugar content or scFOS to replace 30 % of the sugar content. For each study, the two products were tested once under a double-blind and cross-over design with at least 7 d between the two tests. Glucose and insulin were measured using standard methods in blood samples collected with a venous catheter for 120 min during a kinetic test. For the dairy desserts, replacing 30 % of the sugars with scFOS significantly reduced postprandial glycaemic (AUC0-120 min; P = 0·020) and insulinaemic (AUC0-120 min; P = 0·003) responses. For the pound cakes, the glycaemic response was not altered (AUC0-120 min; P = 0·322) while the insulinaemic response tended to be lower (AUC0-120 min; P = 0·067). This study showed that scFOS can be used to replace sugars with the benefit of lowering the postprandial glycaemic response without increasing the insulinaemic response. The effect might be modulated by other parameters (e.g. fat content) of the food matrices.
Healthcare Utilization and Costs of Knee or Hip Replacements versus Pain-Relief Injections
Pasquale, Margaret K.; Louder, Anthony M.; Cheung, Raymond Y.; Reiners, Andrew T.; Mardekian, Jack; Sanchez, Robert J.; Goli, Veerainder
2015-01-01
Background Given the dramatic increase in total knee and hip replacement procedures among the US population aged 45 years and older, there is a need to compare the downstream healthcare utilization and costs between patients who undergo joint replacement and those who receive intraarticular injections as a low-cost alternative. Objective To compare changes in osteoarthritis (OA)-related healthcare utilization and costs for Medicare members with OA who underwent knee or hip replacement versus those receiving steroid or viscosupplementation injections. Methods Medicare members aged ≥45 years diagnosed with OA were identified for this retrospective longitudinal study. Data were compared for patients who underwent primary knee or hip replacement surgery between July 1, 2007, and June 30, 2012, and those receiving injection of pain-relief medication during the same period. The date of joint replacement surgery was considered the index date. For the comparison cohort, the index date was 180 days postinjection of the first intraarticular injection. Medical and pharmacy claims were examined longitudinally in 90-day increments, from 180 days preindex until 360 days postindex. Difference-in-difference analyses were conducted to compare the change in OA-related healthcare costs, postindex versus preindex, between the study cohorts. Time-to-event analyses were used to measure rates of readmissions and venous thromboembolism (VTE). Results The mean age was 70.7 years for patients with knee replacement, 71.7 years for those with hip replacement, and 71.1 years for those receiving pain-relief injection (P <.0001). The RxRisk-V comorbidity index scores were 4.7, 4.4, and 4.8, respectively (P <.0001). Difference-in-difference analyses indicated that decreases in OA-related costs were greater for the joint replacement cohorts (coefficient for knee replacement*time: −0.603; hip replacement*time: −0.438; P <.001 for both) than for the comparison cohort. The VTE rates were 5.6% (knee) and 5.1% (hip) postsurgery versus 1.4% (knee) and 1.3% (hip) presurgery. Conclusion The overall difference-in-difference results showed a greater decrease in healthcare utilization and costs for the members with joint replacement than for those receiving injection. PMID:26557232
Testing protocols to ensure performance of high asphalt binder replacement mixes using RAP and RAS.
DOT National Transportation Integrated Search
2015-12-01
The use of reclaimed asphalt pavement (RAP) and recycled asphalt shingles (RAS) in asphalt concrete (AC) mixtures can reduce demand for virgin aggregates and asphalt binder, bringing environmental and economic benefits. However, replacing virgin asph...
Evaluation of a novel nicotine inhaler device: part 1--arterial and venous pharmacokinetics.
Moyses, Chris; Hearn, Alex; Redfern, Andrew
2015-01-01
In the United Kingdom, licensed nicotine-containing products can be recommended to reduce the harm associated with smoking. Many smokers find currently available nicotine replacement products unsatisfactory. The arterial and venous pharmacokinetics (PK) of nicotine delivered via a novel inhaler device were determined. Results are reported for Parts A (N = 18) and C (N = 18) of a 4-part (A-D) Phase I study. Participants (18-55 years, ≥ 10 cigarettes/day, smoking within 1 hr of waking, expired carbon monoxide >10 ppm on screening) orally inhaled 2 single doses of nicotine (2 of 3 dose levels [0.22, 0.45, and 0.67 mg]) (Part A) and repeated hourly doses of 0.67 mg nicotine for 12 hr (Part C), via the novel device. Arterial and venous PK and tolerability were assessed. In Part A, mean arterial plasma nicotine concentrations at 2 min after the start of inhalation were 1.10, 2.06, and 2.59 ng/mL for the 0.22, 0.45, and 0.67 mg doses, respectively. Mean maximum arterial plasma nicotine concentrations (C(max)) were 2.11, 3.73, and 4.38 ng/mL and mean times to C(max) were 10.2, 7.3, and 6.5 min after the start of inhalation for the 0.22, 0.45, and 0.67 mg doses, respectively. In Part C, the mean pre- and postdose venous plasma nicotine concentration increased steadily and fluctuated in the range 8-10 mg/mL after 9 hr. The novel device was well tolerated; most adverse events were mild. The novel inhaler device delivers nicotine rapidly into the systemic circulation and offers a viable alternative to cigarettes for those finding it difficult to quit the behavioral and sensorial aspects of smoking. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco.
NASA Technical Reports Server (NTRS)
Westby, Christian M.; Platts, Steven H.
2010-01-01
The incidence of orthostatic intolerance after space flight is disproportionally higher in female compared to male crewmembers (83% vs. 20%). Experimental and human data suggest that the loss of orthostatic tolerance is due, at least in part, to microgravity-induced changes in venous compliance and that these changes are specific to the lower body. It is unknown however, whether the changes in venous compliance are different between males and females after space flight, and whether this is related to the disparity in orthostatic intolerance between the sexes. Using 6deg head-down bed rest (BR) as a model of space flight, we tested the following hypotheses; 1) females, compared to males, would experience a greater increase in venous compliance in dorsal foot veins as an effect of BR and 2) no differences in venous compliance would be found in dorsal hand veins between sexes and across BR days. Using 2-D ultrasound, dorsal hand (DHV) and foot vein (DFV) responses (diameter; expressed as sq mm) to 40 mmHg of congestion pressure (compliance) and to intravenous infusion of phenylephrine (PE; 3160ng/min) were determined in 10 females and 16 males before and after 60 days of BR. The relation between changes in vein diameter (in response to pressure and PE), sex, limb, and BR days were determined using a mixed-effect linear regression. It was found that after 60 days of BR, DFV dilator response to pressure was significantly greater in females and significantly less in males compared to pre-BR. As expected, there were no differences in DHV dilator response between sexes nor was there a significant difference between pre and post measures within groups. Notably, the venoconstrictor response to infusions of PE in the DHV and DFV where similar between sexes and across BR days. In conclusion, this study demonstrates that after 60 days of BR, dorsal foot veins are more compliant in women and less compliant in men. Moreover, the changes in lower body vein compliance in females do not appear to be due to changes in vasoconstrictor tone as their response to PE was preserved and similar to that in males. Taken together these data suggest that the higher incidence of orthostatic intolerance in females after space flight is due to increased venous compliance in the lower body which could translate to lower venous filling pressures and a reduced stroke volume.
Reyad, Amal Rashad; Elkharboutly, Walaa; Wahba, Ashraf; Elmorshedi, Mohamed; Hasaneen, Nadia A
2013-08-01
Splanchnic hypoperfusion during abdominal surgery contributes to postoperative gut sepsis and mortality. Dobutamine is an inotrope with vasodilator properties that improve hepatosplanchnic perfusion. The aim of this study was to examine the effect of intraoperative dobutamine infusion during Whipple surgery on splanchnic perfusion, hemodynamic, and overall postoperative outcome. Sixty patients were randomly allocated to receive intraoperatively (3 μg/kg per minute or 5 μg/kg per minute) doses of dobutamine or saline. Baseline measurements included hemodynamic parameters, gastric tonometric parameters, and arterial and mixed venous gases. These patients had a follow-up for development for in-hospital morbidity and mortality. Intraoperative use of dobutamine increased oxygen-derived parameters as evidenced by increased mixed venous oxygen saturation. Tonometered gastric mucosal pH, a surrogate for splanchnic perfusion, increased in patients who received intraoperative dobutamine. Patients in the dobutamine groups demonstrated significant higher heart rates, premature ventricular contraction arrhythmias, and electrocardiographic signs of ischemia. Mean arterial blood pressure demonstrated no significant difference among groups. The overall incidence of postoperative complications was higher in control group 70 % vs 20% to 40% in dobutamine groups. Intraoperative use of dobutamine improved global oxygen delivery, splanchnic perfusion, and postoperative outcome after Whipple surgery. These findings may be of clinical importance when the therapeutic goal is to improve gut perfusion. Copyright © 2013 Elsevier Inc. All rights reserved.
[Microbiological and biochemical characteristics of inflammatory tissues in the periodontium].
Surna, Algimantas; Sakalauskiene, Jurgina; Vitkauskiene, Astra; Saferis, Viktoras
2008-01-01
To investigate bacterial populations in subgingival and supragingival plaque samples of patients with inflammatory periodontal diseases and activities of the lysosomal enzymes--lysozyme, alkaline phosphatase, and beta-glucuronidase--in peripheral venous blood, in gingival crevicular fluid, and mixed nonstimulated saliva. The study included 60 patients with inflammatory periodontal diseases without any internal pathology and 24 periodontally healthy subjects. Molecular genetic assay (Micro-IDent plus, Germany) for complex identification of additional six periodontopathic bacteria was applied. The activity of lysozyme was determined turbidimetrically, the activity of alkaline phosphatase--spectrophotometrically with a "Monarch" biochemical analyzer, the activity beta-glucuronidase--according to the method described by Mead et al. and modified by Strachunskii. A statistically significant association between clinical and bacteriological data was found in the following cases: gingival bleeding in the presence of Eubacterium nodatum, Eikenella corrodens, Capnocytophaga spp. (P<0.01); pathological periodontal pockets in the presence of Peptostreptococcus micros (alpha< or =0.05 and beta< or =0.2), Fusobacterium nucleatum (alpha< or =0.05 and beta< or =0.2), Campylobacter rectus (alpha< or =0.05 and beta< or =0.2), and Capnocytophaga spp. (P<0.05); and satisfactory oral hygiene in the presence of all microorganisms investigated (P<0.05). The activity of lysozyme in gingival crevicular fluid and mixed nonstimulated saliva indicates the severity of periodontal inflammation. Based on clinical data, in assessing the amount of lysozyme in mixed nonstimulated saliva, sensitivity and specificity of 100% was found. Increased activities of lysozyme, alkaline phosphatase, and beta-glucuronidase were found in peripheral venous blood of patients with inflammatory periodontal disease as compared to control group. The main principles of the treatment of periodontal inflammatory diseases should be based on microorganism elimination, creation of individual treatment means affecting microflora in the mouth and immune system of macroorganisms.
Use of fiber reinforced concrete for concrete pavement slab replacement : [summary].
DOT National Transportation Integrated Search
2014-03-01
Replacing cracked concrete in roadways requires : lanes to be closed and traff c disrupted. One way : to reduce road closure time is to reduce concrete : curing time. To accelerate curing time, pavement : engineers mix a very low water-cement ratio w...
Review of non-nuclear density gauges as possible replacements for ITD's nuclear density gauges.
DOT National Transportation Integrated Search
2015-01-01
This report examines the possibility of replacing nuclear density gauges (NDGs) with non-nuclear density gauges (NNDGs) to : measure density of hot mix asphalt (HMA) and unbound pavement layers in the field. The research team evaluated the : effectiv...
Mandolesi, Sandro; Marceca, Giuseppe; Moser, Jon; Niglio, Tarcisio; d'Alessandro, Aldo; Ciccone, Matteo Marco; Zito, Annapaola; Mandolesi, Dimitri; d'Alessandro, Alessandro; Fedele, Francesco
2015-01-01
The aim of the study is to evaluate the clinical and X-ray results of the Upper Cervical Chiropractic care through the specific adjustments (corrections) of C1-C2 on patients with chronic venous cerebral-spinal insufficiency (CCSVI) and multiple sclerosis (MS). We studied a sample of 77 patients before and after the Upper Cervical Chiropractic care, and we analyzed: A) The change of the X-ray parameters; B) The clinical results using a new set of questions. The protocol of the C1- C2 upper Cervical Chiropractic treatment, specific for these patients, lasts four months. From a haemodynamic point of view we divided the patients in 3 types: Type 1 - purely vascular with intravenous alterations; Type 2 - "mechanical" with of external venous compressions; Type 3 - mixed. We found an improvement in all kinds of subluxations after the treatment with respect to the pre-treatment X-ray evaluation, with a significant statistical difference. The differences between the clinical symptoms before and after the specific treatment of C1-C2 are statistically significant with p<0.001 according to the CHI-Square test revised by Yates. The preliminary X-ray and clinical improvements of the Upper Cervical Chiropractic corrections on C1- C2 on these patients with CCSVI and MS encourage us to continue with our studies. We believe that the Upper Cervical correction on C1-C2 could be the main non-invasive treatment of the CCSVI mechanical type in patients with MS. Further studies are required to evaluate the correlation between the Upper Cervical Chiropractic correction on C1-C2 on the cerebral venous drainage and the cerebro-spinal fluid.
Yapakçı, Ece; Ecevit, Ayşe; İnce, Deniz Anuk; Gökdemir, Mahmut; Tekindal, M. Agah; Gülcan, Hande; Tarcan, Aylin
2014-01-01
Background: Inferior vena cava (IVC) oxygen saturation as an indicator of mixed venous oxygenation may be valuable for understanding postnatal adaptations in newborn infants. It is unknown how this parameter progresses in critically ill premature infants. Aims: To investigate IVC oxygen saturation during the first three days of life in preterm infants with and without patent ductus arteriosus (PDA). Study Design: Case-control study. Methods: Twenty-seven preterm infants were admitted to the Neonatal Intensive Care. Preterm infants with umbilical venous catheterization were included in the study. Six umbilical venous blood gas values were obtained from each infant during the first 72 hours of life. Preterm infants in the study were divided into two groups. Haemodynamically significant PDA was diagnosed by echocardiography in 11 (41%) infants before the 72nd hour of life in the study group and ibuprofen treatment was started, whereas 16 (59%) infants who didn’t have haemodynamically significant PDA were included in the control group. Results: In the entire group, the highest value of mean IVC oxygen saturation was 79.9% at the first measurement and the lowest was 64.8% at the 72nd hour. Inferior vena cava oxygen saturations were significantly different between the study and control groups. Post-hoc analysis revealed that the first and 36th hour measurements made the difference (p=0.01). Conclusion: Inferior vena cava oxygen saturation was found to be significantly different between preterm infants with and without PDA. Further studies are needed to understand the effect of foetal shunts on venous oxygenation during postnatal adaptation in newborn infants. PMID:25337418
Interventions to enhance patient compliance with leg ulcer treatment: a review of the literature.
Van Hecke, Ann; Grypdonck, Maria; Defloor, Tom
2008-01-01
Non-compliance with compression therapy and with leg exercises and leg elevation is a common problem, often reported in patients with venous leg ulceration. Studies on compliance-enhancing interventions and the effectiveness of these interventions in patients with venous leg ulceration were reviewed. MEDLINE, Cochrane, Embase and CINAHL were explored up to April 2005. Reference lists, wound care journals and conference proceedings were searched. Experts and manufacturers of compression systems were contacted. Studies were eligible if they included patients with venous or mixed leg ulcers and reported patient compliance outcome. Twenty studies were included. Most studies describe patient compliance as the extent to which the compression system was worn and/or the extent to which treatment regimen was followed. Self-reporting was the most commonly used method of compliance assessment. There are indications that class III stockings for patients with venous ulcers enhance compliance compared with short stretch compression bandages. No real evidence is found that intermittent pneumatic compression systems improved compliance. There is no well-documented evidence that healthcare system interventions increase compliance. Educational programmes combining cognitive, behavioural and affective components were shown to have a positive effect on leg elevation, but not on compliance with compression therapy. The included studies have a lack of consistency in defining the standard and operationalization of compliance. Patient compliance plays an ancillary role in research. No study has been able to offer an acceptable and well-documented solution to the non-compliance problem. Research might focus on the development of comprehensive compliance-enhancing strategies. A stronger commitment of healthcare providers and society is needed to make progress in this area. The scope of nursing must be expanded to also include the problems experienced by patients with leg ulcers and the improvement of patient compliance.
Arterialised hepatic nodules in the Fontan circulation: hepatico-cardiac interactions.
Bryant, Timothy; Ahmad, Zaheer; Millward-Sadler, Harry; Burney, Kashif; Stedman, Brian; Kendall, Tim; Vettukattil, Joseph; Haw, Marcus; Salmon, Anthony P; Cope, Richard; Hacking, Nigel; Breen, David; Sheron, Nick; Veldtman, Gruschen R
2011-09-15
Hypervascular nodules occur commonly when there is hepatic venous outlet obstruction. Their nature and determinants in the Fontan circulation is poorly understood. We reviewed the records of 27 consecutive Fontan patients who had computerized tomography scan (CT) over a 4 year period for arterialised nodules and alterations in hepatic flow patterns during contrast enhanced CT scans and related these findings to cardiac characteristics. Mean patient age was 24 ± 5.8 years, (range 16.7-39.8) and mean Fontan duration was 16.8 ± 4.8 years (range 7.3-28.7). Twenty-two patients demonstrated a reticular pattern of enhancement, 4 a zonal pattern and only 1 demonstrated normal enhancement pattern. Seven (26%) patients had a median of 4 (range 1-22) arterialised nodules, mean size 1.8 cm (range 0.5 to 3.2 cm). All nodules were located in the liver periphery, their outer aspect lying within 2 cm of the liver margin. Patients with nodules had higher mean RA pressures (18 mmHg ± 5.6 vs. 13 mmHg ± 4, p=0.025), whereas their mixed venous saturation and aortic saturation was not significantly different (70% ± 11 vs. 67% ± 9 and 92% ± 10 vs. 94% ± 4, p>0.05). Post-mortem histology suggests focal nodular hyperplasia is the underlying pathology. ConclusionsAbnormalities of hepatic blood flow and the presence of arterialised nodules are common in the failing Fontan circulation. They occur especially when central venous pressures are high, and very likely indicate arterialisation of hepatic blood flow and reciprocal portal venous deprivation. The underlying pathology is most likely focal nodular hyperplasia. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Azmi, N. B.; Khalid, F. S.; Irwan, J. M.; Mazenan, P. N.; Zahir, Z.; Shahidan, S.
2018-04-01
This study is focuses to the performance of composite sand cement brick containing recycle concrete aggregate and waste polyethylene terephthalate. The objective is to determine the mechanical properties such as compressive strength and water absorption of composite brick containing recycled concrete aggregate and polyethylene terephthalate waste and to determine the optimum mix ratio of bricks containing recycled concrete aggregate and polyethylene terephthalate waste. The bricks specimens were prepared by using 100% natural sand, they were then replaced by RCA at 25%, 50% and 75% with proportions of PET consists of 1.0%, 1.5%, 2.0% and 2.5% by weight of natural sand. Based on the results of compressive strength, it indicates that the replacement of RCA shows an increasing strength as the strength starts to increase from 25% to 50% for both mix design ratio. The strength for RCA 75% volume of replacement started to decrease as the volume of PET increase. However, the result of water absorption with 50% RCA and 1.0% PET show less permeable compared to control brick at both mix design ratio. Thus, one would expect the density of brick decrease and the water absorption to increase as the RCA and PET content is increased.
Double-arterial cannulation for aortic valve replacement with porcelain aorta.
De Paulis, Ruggero; Maselli, Daniele; Scaffa, Raffaele; Nardella, Saverio
2009-10-01
We describe a new technique of aortic valve replacement (AVR) in patients with porcelain aorta. Three patients (mean age 75 years) were treated. The cardiopulmonary bypass (CPB) was established after side-graft right axillary artery and direct femoral artery cannulation. Venous drainage was obtained by atrio-caval cannulation. The procedures were performed in mild hypothermia (30 degrees C). Cerebral perfusion was carried out by clamping the innominate artery and all epiaortic vessels. The aorta was endoclamped by a Foley balloon inserted into the isthmus. The aorta was then opened longitudinally for 10 cm to expose and replace the aortic valve. Near-infra-red spectroscopy (NIRS) and bilateral radial artery pressure were used to monitor effective cerebral perfusion. Operative mortality was absent. The mean time of CPB was 73 min. NIRS-derived tissue oxygenation was maintained above 55%. Postoperative course was uneventful. This technique has several advantages: first, the cannulation of right axillary and the common femoral artery allows simultaneous cerebral and systemic perfusion. Second, any form of cross-clamp is avoided and the aorta is occluded away from the epiaortic vessels. Third, there is an increased freedom to choose the best place for aortotomy.
Design and analysis of mixed cropping experiments for indigenous Pacific Islands
Mareko P. Tofinga
1993-01-01
Mixed cropping (including agroforestry) often gives yield advan-tages as opposed to monocropping. Many criteria have been used to assess yield advantage in crop mixtures. Some of these are presented. In addition, the relative merits of replacement, additive and bivariate factorial designs are discussed. The concepts of analysis of mixed cropping are applied to an...
Amylose-potassium oleate inclusion complex in plain set-style yogurt.
Singh, Mukti; Byars, Jeffrey A; Kenar, James A
2014-05-01
Health and wellness aspirations of U.S. consumers continue to drive the demand for lower fat from inherently beneficial foods such as yogurt. Removing fat from yogurt negatively affects the gel strength, texture, syneresis, and storage of yogurt. Amylose-potassium oleate inclusion complexes (AIC) were used to replace skim milk solids to improve the quality of nonfat yogurt. The effect of AIC on fermentation of yogurt mix and strength of yogurt gel was studied and compared to full-fat samples. Texture, storage modulus, and syneresis of yogurt were observed over 4 weeks of storage at 4 °C. Yogurt mixes having the skim milk solids partially replaced by AIC fermented at a similar rate as yogurt samples with no milk solids replaced and full-fat milk. Initial viscosity was higher for yogurt mixes with AIC. The presence of 3% AIC strengthened the yogurt gel as indicated by texture and rheology measurements. Yogurt samples with 3% AIC maintained the gel strength during storage and resulted in low syneresis after storage for 4 wk. © 2014 Institute of Food Technologists®
Lehle, Karla; Philipp, Alois; Zeman, Florian; Lunz, Dirk; Lubnow, Matthias; Wendel, Hans-Peter; Göbölös, Laszlo; Schmid, Christof; Müller, Thomas
2015-01-01
The aim of the study was to explore the prevalence and risk factors for technical-induced hemolysis in adults supported with veno-venous extracorporeal membrane oxygenation (vvECMO) and to analyze the effect of hemolytic episodes on outcome. This was a retrospective, single-center study that included 318 adult patients (Regensburg ECMO Registry, 2009-2014) with acute respiratory failure treated with different modern miniaturized ECMO systems. Free plasma hemoglobin (fHb) was used as indicator for hemolysis. Throughout a cumulative support duration of 4,142 days on ECMO only 1.7% of the fHb levels were above a critical value of 500 mg/l. A grave rise in fHb indicated pumphead thrombosis (n = 8), while acute oxygenator thrombosis (n = 15) did not affect fHb. Replacement of the pumphead normalized fHb within two days. Neither pump or cannula type nor duration on the first system was associated with hemolysis. Multiple trauma, need for kidney replacement therapy, increased daily red blood cell transfusion requirements, and high blood flow (3.0-4.5 L/min) through small-sized cannulas significantly resulted in augmented blood cell trauma. Survivors were characterized by lower peak levels of fHb [90 (60, 142) mg/l] in comparison to non-survivors [148 (91, 256) mg/l, p≤0.001]. In conclusion, marked hemolysis is not common in vvECMO with modern devices. Clinically obvious hemolysis often is caused by pumphead thrombosis. High flow velocity through small cannulas may also cause technical-induced hemolysis. In patients who developed lung failure due to trauma, fHb was elevated independantly of ECMO. In our cohort, the occurance of hemolysis was associated with increased mortality.
Lehle, Karla; Philipp, Alois; Zeman, Florian; Lunz, Dirk; Lubnow, Matthias; Wendel, Hans-Peter; Göbölös, Laszlo; Schmid, Christof; Müller, Thomas
2015-01-01
The aim of the study was to explore the prevalence and risk factors for technical-induced hemolysis in adults supported with veno-venous extracorporeal membrane oxygenation (vvECMO) and to analyze the effect of hemolytic episodes on outcome. This was a retrospective, single-center study that included 318 adult patients (Regensburg ECMO Registry, 2009–2014) with acute respiratory failure treated with different modern miniaturized ECMO systems. Free plasma hemoglobin (fHb) was used as indicator for hemolysis. Throughout a cumulative support duration of 4,142 days on ECMO only 1.7% of the fHb levels were above a critical value of 500 mg/l. A grave rise in fHb indicated pumphead thrombosis (n = 8), while acute oxygenator thrombosis (n = 15) did not affect fHb. Replacement of the pumphead normalized fHb within two days. Neither pump or cannula type nor duration on the first system was associated with hemolysis. Multiple trauma, need for kidney replacement therapy, increased daily red blood cell transfusion requirements, and high blood flow (3.0–4.5 L/min) through small-sized cannulas significantly resulted in augmented blood cell trauma. Survivors were characterized by lower peak levels of fHb [90 (60, 142) mg/l] in comparison to non-survivors [148 (91, 256) mg/l, p≤0.001]. In conclusion, marked hemolysis is not common in vvECMO with modern devices. Clinically obvious hemolysis often is caused by pumphead thrombosis. High flow velocity through small cannulas may also cause technical-induced hemolysis. In patients who developed lung failure due to trauma, fHb was elevated independantly of ECMO. In our cohort, the occurance of hemolysis was associated with increased mortality. PMID:26606144
Comparison of thromboprophylaxis patterns in arthroplasty in public and private hospitals
Cortada, Aline Pinheiro dos Santos; da Silva, Telma Gomes; da Silva, André Campos; Golmia, Ricardo Prado; Guerra, Renata Leborato; Takemoto, Maíra Libertad Soligo; Monteiro, Roberta Dyonisio Canaveira; Scheinberg, Morton Aaron
2015-01-01
Objective To compare therapy for prophylaxis of venous thromboembolism and costs related to hospitalization of patients undergoing total knee and hip replacement within the context of the Brazilian health system. Methods A retrospective study of patients undergoing arthroplasty in 2010 in a public hospital and two private hospitals in the state of São Paulo, conducted by means of medical record review. Costs were estimated based on the use of health care resources during hospitalization. A descriptive analysis was performed using frequency and mean (standard deviation) according to the type of care delivered (by public or private organization). Results A total of 215 patients were evaluated, and 56.3% were submitted to knee surgery and 43.7%, to hip replacement. Approximately 88% and 98% of patients from public and private health services, respectively, received some form of venous thromboembolism prophylaxis, and enoxaparin was the drug most widely used in both systems. The total cost of prophylaxis was R$ 1,873.01 (R$ 26.38 per patient) in the public service and R$ 21,559.73 (R$ 163.33 per patient) in the private service. For the individuals who presented with thromboembolism, the average cost of hospitalization was R$ 6,210.80 and R$ 43,792.59 per patient in public and private health services, respectively. Conclusion Thromboembolism prophylaxis in patients undergoing arthroplasty is most commonly used in the private health services than public organizations, despite its high costs in both services. The cost per patient with thrombosis during hospitalization was higher than the total cost of prophylaxis, suggesting that prevention is associated to better cost-benefit ratio. PMID:26313439
Effect of Surface Hydration on Antifouling Properties of Mixed Charged Polymers.
Leng, Chuan; Huang, Hao; Zhang, Kexin; Hung, Hsiang-Chieh; Xu, Yao; Li, Yaoxin; Jiang, Shaoyi; Chen, Zhan
2018-05-07
Interfacial water structure on a polymer surface in water (or surface hydration) is related to the antifouling activity of the polymer. Zwitterionic polymer materials exhibit excellent antifouling activity due to their strong surface hydration. It was proposed to replace zwitterionic polymers using mixed charged polymers because it is much easier to prepare mixed charged polymer samples with much lower costs. In this study, using sum frequency generation (SFG) vibrational spectroscopy, we investigated interfacial water structures on mixed charged polymer surfaces in water, and how such structures change while exposing to salt solutions and protein solutions. The 1:1 mixed charged polymer exhibits excellent antifouling property while other mixed charged polymers with different ratios of the positive/negative charges do not. It was found that on the 1:1 mixed charged polymer surface, SFG water signal is dominated by the contribution of the strongly hydrogen bonded water molecules, indicating strong hydration of the polymer surface. The responses of the 1:1 mixed charged polymer surface to salt solutions are similar to those of zwitterionic polymers. Interestingly, exposure to high concentrations of salt solutions leads to stronger hydration of the 1:1 mixed charged polymer surface after replacing the salt solution with water. Protein molecules do not substantially perturb the interfacial water structure on the 1:1 mixed charged polymer surface and do not adsorb to the surface, showing that this mixed charged polymer is an excellent antifouling material.
Robinson, Sian; Zincuk, Aleksander; Larsen, Ulla Lei; Ekstrøm, Claus; Toft, Palle
2014-06-13
Previous pharmacokinetic trials suggested that 40 mg subcutaneous enoxaparin once daily provided inadequate thromboprophylaxis for intensive care unit patients. Critically ill patients with acute kidney injury are at increased risk of venous thromboembolism and yet are often excluded from these trials. We hypothesized that for critically ill patients with acute kidney injury receiving continuous renal replacement therapy, a dose of 1 mg/kg enoxaparin subcutaneously once daily would improve thromboprophylaxis without increasing the risk of bleeding. In addition, we seek to utilize urine output prior to discontinuing dialysis, and low neutrophil gelatinase-associated lipocalin in dialysis-free intervals, as markers of renal recovery. In a multicenter, double-blind randomized controlled trial in progress at three intensive care units across Denmark, we randomly assign eligible critically ill adults with acute kidney injury into a treatment (1 mg/kg enoxaparin subcutaneously once daily) or control arm (40 mg enoxaparin subcutaneously once daily) upon commencement of continuous renal replacement therapy.We calculated that with 133 patients in each group, the study would have 80% power to show a 40% reduction in the relative risk of venous thromboembolism with 1 mg/kg enoxaparin, at a two-sided alpha level of 0.05. An interim analysis will be conducted after the first 67 patients have been included in each group.Enrolment began in March 2013, and will continue for two years. The primary outcome is the occurrence of venous thromboembolism. Secondary outcomes include anti-factor Xa activity, bleeding, heparin-induced thrombocytopenia, filter lifespan, length of stay, ventilator free days, and mortality. We will also monitor neutrophil gelatinase-associated lipocalin and urine volume to determine whether they can be used as prognostic factors for renal recovery. Critically ill unit patients with acute kidney injury present a particular challenge in the provision of thromboprophylaxis. This study hopes to add to the growing evidence that the existing recommendation of 40 mg enoxaparin is inadequate and that 1 mg/kg is both safe and effective for thromboprophylaxis.In addition, the study seeks to identify predictors of renal recovery allowing for the proper utilization of resources. EU Clinical Trials Register: EudraCT number: 2012-004368-23, 25 September 2012.
Wali, Mahmoud A; Eid, Refaat A; Dewan, Madhu; Al-Homrany, Mohammad A
2006-10-01
Native cephalic vein remains the superior dialysis conduit, even 30 years after it was first described. However, up to 37% of hemodialysis patients develop progressive stenosis in the venous circuit of arterio-venous fistula (AVF), which may later cause thrombosis and occlusion. To study the pre-existing morphological changes in the wall of the cephalic vein before AVF construction, we collected 23 cephalic vein specimens from 3 normal, young trauma patients and 20 renal failure patients. The samples were collected at the time of vascular repair in the first group and AVF construction in the second group. Sections were prepared and stained with hematoxylin & eosin (H&E), Masson's trichrome and Verhoff von Gieson's stains. Compared with normal cephalic veins, all pre-access cephalic veins showed generalized thickening of the wall due to intimal hyperplasia and replacement by collagenous, fibrous tissue. Other changes were disruption or loss of internal elastic lamina in 9 (45%) patients, loss of endothelial cell layer in 6 (30%), atrophy or loss of the muscle layer in 6 (30%), mucoid or myxoid degeneration in 6 (30%), inflammatory cell infiltration of the wall in 5 (25%), mural calcification in 3 (15%) and telangiectasia in 2 (10%). Another important finding was the marked accumulation of spindle-shaped smooth muscle cells (SMCs) on the de-epithelialized intimal surface in areas of intimal hyperplasia. In conclusion, most of the apparently normal cephalic veins of the renal failure patients showed morphological abnormalities at the time of AVF construction. This may influence the outcome of shunts in terms of future stenosis and failure.
Forni, Cristiana; D'Alessandro, Fabio; Gambino, Orazio; Amodeo, Alfredo; Pignotti, Elettra; Zanotti, Enrichetta; Tremosini, Morena; Trofa, Carmela; Sabattini, Tania; Matino, Federica; Genco, Rossana; Schiavone, Miguel; Bombino, Caterina; Mini, Sandra; Rocchegiani, Laura; Notarnicola, Teresa; Capezzali, Daniela; Boschi, Rita; Loro, Loretta
2012-01-01
Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC), on the incidence of phlebitis. A randomized controlled trial. The type of dressing could contribute to the incidence of phlebitis, infiltration and accidental removals but the results of the studies are contrasting and samples are limited. To compare the effectiveness of a transparent polyurethane sterile dressing on the rate of phlebitis associated to peripheral venous catheter (PVC) vs a non sterile sticking plaster in use in current practice (standard dressing). Randomized controlled trial. Participants. 1061 PVCs (703 patients, adults and children) at a research orthopedic hospital in the north of Italy; 540 PVCs allocated to receive the sterile and 521 the standard dressing. 96 PVCs were excluded for phlebitis, 48 (9.6%) in the sterile and 48 (10.1%) in the standard dressing group, RR 0.96 (95%CI 0.697 - 1.335). Accidental removal of the PVCs was more frequent with the sterile dressing (9.6% vs 6.3%) but the number of catheters removed without complications was larger in the standard dressing group (48.9% vs 54.9% P=0.0503). Eighty-five PVCs were replaced for detachment of the dressing (50, 9.2% sterile and 35, 6.7% standard dressing). The cheapest transparent sterile dressing costs 32 cents while the standard 9 cents. A sticking non sterile plasters is not influential on the rate of phlebitis and ensures an good fix of the PVC compared the transparent sterile dressing to of polyurethane film.
Mulé, Sébastien; Pigneur, Frédéric; Quelever, Ronan; Tenenhaus, Arthur; Baranes, Laurence; Richard, Philippe; Tacher, Vania; Herin, Edouard; Pasquier, Hugo; Ronot, Maxime; Rahmouni, Alain; Vilgrain, Valérie; Luciani, Alain
2018-05-01
To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) < 0.05 was considered significant. Mean HCC late-arterial and portal iodine concentrations were 22.7±12.7 mg/mL and 18.7±8.3 mg/mL, respectively. Late-arterial iodine concentration was significantly related to BV (mixed-effects model F statistic (F)=28.52, p<0.0001), arterial BF (aBF, F=17.62, p<0.0001), hepatic perfusion index (F=28.24, p<0.0001), positive enhancement integral (PEI, F=66.75, p<0.0001) and mean slope of increase (F=32.96, p<0.0001), while portal-venous iodine concentration was mainly related to BV (F=29.68, p<0.0001) and PEI (F=66.75, p<0.0001). In advanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.
The ecology of mixed severity fire regimes in Washington, Oregon, and Northern California
David Perry; Paul Hessburg; Carl Skinner; Thomas Spies; Scott Stephens; Alan Henry Taylor; Jerry Franklin; Brenda McComb; Greg Riegel
2011-01-01
Forests characterized by mixed-severity fires occupy a broad moisture gradient between lower elevation forests typified by low-severity fires and higher elevation forests in which high-severity, stand replacing fires are the norm. Mixed-severity forest types are poorly documented and little understood but likely occupy significant areas in the western United States. By...
2013-11-01
surface. Biopolymer (first application), and biopolymer plus seed (second application), were applied using a hydroseeder. 20 Figure 9. Initial...fluid replacement. Replacement fluids can be commercial mixes such as water, Gatorade, or fruit juices . • Work/Rest Regimens: Implementation of a
Band gap and refractive index tunability in thallium based layered mixed crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gasanly, N. M., E-mail: nizami@metu.edu.tr; Virtual International Scientific Research Centre, Baku State University, Baku 1148
2015-07-21
Compositional variation of the band gap energy and refractive index of TlMeX{sub 2}-type (Me = Ga or In and X = S or Se) layered mixed crystals have been studied by the transmission and reflection measurements in the wavelength range of 400–1100 nm. The analysis of absorption data of TlGa{sub 1-x}In{sub x}Se{sub 2}, TlGa(S{sub 1−x}Se{sub x}){sub 2}, TlGa{sub 1−x}In{sub x}S{sub 2}, and TlIn(Se{sub 1−x}S{sub x}){sub 2} mixed crystals revealed the presence of both optical indirect and direct transitions. It was found that the energy band gaps of mixed crystals decrease at the replacing of gallium atoms by indium and of sulfur atoms by selenium ones.more » Through the similar replacing of atoms (smaller atoms by larger ones) in the studied mixed crystals, the refractive index shows the quite opposite behavior.« less
Aneurysm of the right ventricular outflow following bovine valved venous conduit insertion.
Boudjemline, Younes; Bonnet, Damien; Agnoletti, Gabriella; Vouhé, Pascal
2003-01-01
A case of aneurysm of the right ventricular outflow tract is described after repair of tetralogy of Fallot using a Contegra supported conduit. Angiograms revealed that the aneurysm was located between the ventricular anastomosis and the proximal ring of the conduit confirming echocardiographic data. Because the conduit between the rings was not dilated, the valve was perfectly functioning. Pulmonary anastomosis was severely stenosed explaining the dilatation seen below. Conduit replacement with resection of the aneurysmal part of the failing conduit was performed. Supported conduits do not eliminate the risk of secondary dilatation below the artificial ring but preserve valvular function.
NASA Astrophysics Data System (ADS)
Matangulu Shrestha, Victor; Anandh, S.; Sindhu Nachiar, S.
2017-07-01
Concrete is a heterogeneous mixture constitute of cement as the main ingredient with a different mix of fine and coarse aggregate. The massive use of conventional concrete has a shortfall in its key ingredients, natural sand and coarse aggregate, due to increased industrialisation and globalisation. To overcome the shortage of material, an alternate material with similar mechanical properties and composition has to be studied, as replacement of conventional concrete. Coconut shell concrete is a prime option as replacement of key ingredients of conventional concrete as coconut is produced in massive quantity in south East Asia. Coconut shell concrete is lightweight concrete and different research is still ongoing concerning about its mix design and composition in the construction industry. Concrete is weak in tension as compared to compression, hence the fibre is used to refrain the crack in the concrete. Coconut fibre is one of many fibres which can be used in concrete. The main aim of this project is to analyse the use of natural by-products in the construction industry, make light weight concrete and eco-friendly construction. This project concerns with the comparison of the mechanical properties of coconut shell concrete and conventional concrete, replacing fine aggregate with quarry dust using coconut fibre. M25 grade of concrete was adopted and testing of concrete was done at the age of 3, 7 and 28 days. In this concrete mix, sand was replaced completely in volumetric measurement by quarry dust. The result was analysed and compared with addition of coconut fibre at varying percentage of 1%, 2%, 3%, 4% and 5%. From the test conducted, coconut shell concrete with quarry dust has the maximum value at 4% of coconut fibre while conventional concrete showed the maximum value at 2% of coconut fibre.
NASA Astrophysics Data System (ADS)
El-Hawary, Moetaz; Ahmed, Mahmoud
2017-09-01
The utilization of some type of cheap filler as partial cement replacement is an effective way of improving concrete sustainability. With the recent trends to reduce water to cement ratio and improve compaction, there is no enough space or water for complete hydration of cement. This means that actually, a portion of mixed cement acts as expensive filler. Replacing this portion with cheaper filler that requires less energy to produce is, therefore, beneficial. Crushed limestone is the most promising filler. This work is to investigate the effect of the amount of limestone fillers on the sustainability and the fresh and mechanical properties of the resulting concrete. A rich mix is designed with a low water/cement ratio of 0.4. Lime is introduced as a replacement percentage of cement. Ratios of 0, 10, 20 and 30% were used. Slump, compressive strength, specific gravity and water absorption are evaluated for every mix. In addition, the effect of the amount of lime on the residual strength of concrete subjected to elevated temperatures is also investigated. Samples are subjected to six different temperature stations of 20, 100, 200, 300, 500 and 700°C for six hours before being cooled and subsequently tested for compressive strength and specific gravity. Sustainability of the tested mixes is evaluated through reductions in the emitted carbon dioxide, energy and reduction in cost. Based on the annual use of concrete in Kuwait, the sustainability benefits resulting from the use of limestone filler in Kuwait are evaluated and assessed. The paper is concluded with the recommendation of the use of 15% limestone filler as partial cement replacement where the properties and the behavior under high temperature of the resulting concrete are almost the same as those of conventional concrete with considerable cost and sustainability benefits.
Cardiovascular transition at birth: a physiological sequence.
Hooper, Stuart B; Te Pas, Arjan B; Lang, Justin; van Vonderen, Jeroen J; Roehr, Charles Christoph; Kluckow, Martin; Gill, Andrew W; Wallace, Euan M; Polglase, Graeme R
2015-05-01
The transition to newborn life at birth involves major cardiovascular changes that are triggered by lung aeration. These include a large increase in pulmonary blood flow (PBF), which is required for pulmonary gas exchange and to replace umbilical venous return as the source of preload for the left heart. Clamping the umbilical cord before PBF increases reduces venous return and preload for the left heart and thereby reduces cardiac output. Thus, if ventilation onset is delayed following cord clamping, the infant is at risk of superimposing an ischemic insult, due to low cardiac output, on top of an asphyxic insult. Much debate has centered on the timing of cord clamping at birth, focusing mainly on the potential for a time-dependent placental to infant blood transfusion. This has prompted recommendations for delayed cord clamping for a set time after birth in infants not requiring resuscitation. However, recent evidence indicates that ventilation onset before cord clamping mitigates the adverse cardiovascular consequences caused by immediate cord clamping. This indicates that the timing of cord clamping should be based on the infant's physiology rather than an arbitrary period of time and that delayed cord clamping may be of greatest benefit to apneic infants.
Lateral sellar compartment O.T. (cavernous sinus): history, anatomy, terminology.
Parkinson, D
1998-08-01
Claudios Galen (119-199 a.d.) dissected lower animals with parasellar carotid retia bathed in venous blood and transposed his findings to human anatomy. Andreas Vesalius (1514-1564) corrected most of Galen's errors but apparently never looked into this small, extradural compartment, nor, apparently, did Winslow (Exposition Anatomique de la Structure du Corps Humain. London: N. Prevast, 1734), who christened it the "cavernous sinus," (CS) presumably thinking that it would resemble the corpora cavernosa of the penis. Multiple surgical explorations, gross dissections, microscopic views, and vascular casts from early fetuses to an 81 year old have been examined and reviewed. The CS is not a dural sinus nor is it cavernous. The compartment is extradural, and the venous structures contained within consist of a greatly variable plexus of extremely thin-walled veins. The name, CS, is a barrier to the understanding of the structure and function of this extradural anatomical jewel box, which contains fat, myelinated and nonmyelinated nerves, arteries, and a plexus of veins. It is proposed that this name be changed, because it is inaccurate and misleading. The replacement should leave no doubt about its meaning. The lateral sellar compartment is descriptive and accurate. The veins within are a parasellar plexus.
Anti-fouling strategies for central venous catheters
Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi
2017-01-01
Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs. PMID:29399528
Anti-fouling strategies for central venous catheters.
Wallace, Alex; Albadawi, Hassan; Patel, Nikasha; Khademhosseini, Ali; Zhang, Yu Shrike; Naidu, Sailendra; Knuttinen, Grace; Oklu, Rahmi
2017-12-01
Central venous catheters (CVCs) are ubiquitous in the healthcare industry and carry two common complications, catheter related infections and occlusion, particularly by thrombus. Catheter-related bloodstream infections (CRBSI) are an important cause of nosocomial infections that increase patient morbidity, mortality, and hospital cost. Innovative design strategies for intravenous catheters can help reduce these preventable infections. Antimicrobial coatings can play a major role in preventing disease. These coatings can be divided into two major categories: drug eluting and non-drug eluting. Much of these catheter designs are targeted at preventing the formation of microbial biofilms that make treatment of CRBSI nearly impossible without removal of the intravenous device. Exciting developments in catheter impregnation with antibiotics as well as nanoscale surface design promise innovative changes in the way that physicians manage intravenous catheters. Occlusion of a catheter renders the catheter unusable and is often treated by tissue plasminogen activator administration or replacement of the line. Prevention of this complication requires a thorough understanding of the mechanisms of platelet aggregation, signaling and cross-linking. This article will look at the advances in biomaterial design specifically drug eluting, non-drug eluting, lubricious coatings and micropatterning as well as some of the characteristics of each as they relate to CVCs.
New oral anticoagulants--a review.
Ghanima, Waleed; Atar, Dan; Sandset, Per Morten
2013-10-01
Dabigatran, rivaroxaban and apixaban are three new oral anticoagulants that have recently been approved in Norway. The aim of this article is to provide an overview of the mechanisms of action, the most important indications and practical advice on the use of these drugs. The review is based on published phase 3 studies, a literature search in PubMed and the authors' clinical experience. Indications for use of the new anticoagulants include thromboprophylaxis after total hip and knee replacement surgery (all three), prevention of stroke and systemic embolism in non-valvular atrial fibrillation (all three), treatment of acute venous thrombosis and secondary prophylaxis after venous thrombosis (currently only rivaroxaban). For the aforementioned indications, these drugs have proven to be non-inferior to standard established anticoagulation therapy. For atrial fibrillation, all three drugs have also shown a lower incidence of intracranial bleeding compared with standard treatment. It is important to limit the use of these drugs to approved indications, to select patients who show good compliance, to rule out contraindications and to identify drug interactions. Monitoring of coagulation is not required, but patients should be followed up regularly to detect conditions that may lead to changes in the expected efficacy or safety.
The durability of concrete containing recycled tyres as a partial replacement of fine aggregate
NASA Astrophysics Data System (ADS)
Syamir Senin, Mohamad; Shahidan, Shahiron; Syazani Leman, Alif; Othman, Nurulain; Shamsuddin, Shamrul-mar; Ibrahim, M. H. W.; Zuki, S. S. Mohd
2017-11-01
Nowadays, uncontrolled disposal of waste materials such as tyres can affect the environment. Therefore, careful management of waste disposal must be done in order to conserve the environment. Waste tyres can be use as a replacement for both fine aggregate and coarse aggregate in the production of concrete. This research was conducted to assess the durability of concrete containing recycled tyres which have been crushed into fine fragments to replace fine aggregate in the concrete mix. This study presents an overview of the use of waste rubber as a partial replacement of natural fine aggregate in a concrete mix. 36 concrete cubes measuring 100mm × 100mm × 100mm and 12 concrete cubes measuring 150mm × 150mm × 150mm were prepared and added with different percentages of rubber from recycled tyres (0%, 3%, 5% and 7%) as fine aggregate replacement. The results obtained show that the replacement of fine aggregate with 7% of rubber recorded a compressive strength of 43.7MPa while the addition of 3% of rubber in the concrete sample recorded a high compressive strength of 50.8MPa. This shows that there is a decrease in the strength and workability of concrete as the amount of rubber used a replacement for fine aggregate in concrete increases. On the other hand, the water absorption test indicated that concrete which contains rubber has better water absorption ability. In this study, 3% of rubber was found to be the optimal percentage as a partial replacement for fine aggregate in the production of concrete.
Pozzolanic activity and durability of nano silica, micro silica and silica gel contained concrete
NASA Astrophysics Data System (ADS)
Al Ghabban, Ahmed; Al Zubaidi, Aseel B.; Fakhri, Zahraa
2018-05-01
This paper aims to investigate the influence of replacement of cement with nano silica, micro silica and silica gel admixtures on pozzolanic activity, the replacement ratio was10% for all admixture, silica gel used in two forms (beads and crushed powder). Also, the water absorption test was investigated for obtaining the durability properties of concrete, in specimens for this test admixtures were added in four different dosages 1%, 2%, 3% and 4% by weight of the cementitious material into the concrete mixture. Experimental investigations of modified concrete were conducted after 28 days of water curing. Results showed that mixes of nano silica and crushed silica gel showed a higher pozzolanic activity index. For the water absorption test, all mixes incorporating nano silica, micro silica and silica gel showed lower absorption than control mixes best result were noticed with crushed silica gel and nano silica mixes. DTA analysis confirms the results for both poisonous activity and water absorption.
Kasten, Robert; Pfirrmann, Gudrun; Voigtländer, Volker
2005-08-01
A 43-year-old male with eunuchoid body proportions and a history of deep venous thromboses in the right leg presented with recurrent ulcers in the right perimalleolar region for 6 years. Karyotyping revealed a 47 XXY Klinefelter's syndrome, while serologic testing showed protein S deficiency, hyperhomocysteinemia and positive lupus anticoagulant. He also had mixed connective tissue disease (Sharp's syndrome) with acrosclerosis, proximal finger edema, Raynaud's phenomenon, and high titers of ANA and U1-RNP-antibodies, as well as osteoporosis. There is evidence that patients with Klinefelter's syndrome are prone to develop connective tissue diseases and thrombophilia as a result of low androgen levels. Substitution of testosterone in Klinefelter's syndrome can have a favorable therapeutic effect on the associated connective tissue disease, thrombophilia and osteoporosis.
Mathematical modelling of a human external respiratory system
NASA Technical Reports Server (NTRS)
1977-01-01
A closed system of algebraic and common differential equations solved by computer is investigated. It includes equations which describe the activity pattern of the respiratory center, the phrenic nerve, the thrust produced by the diaphragm as a function of the lung volume and discharge frequency of the phrenic nerve, as well as certain relations of the lung stretch receptors and chemoreceptors on various lung and blood characteristics, equations for lung biomechanics, pulmonary blood flow, alveolar gas exchange and capillary blood composition equations to determine various air and blood flow and gas exchange parameters, and various gas mixing and arterial and venous blood composition equations, to determine other blood, air and gas mixing characteristics. Data are presented by means of graphs and tables, and some advantages of this model over others are demonstrated by test results.
Hu, Zhiyong; Xu, Lili; Zhu, Zhirui; Seal, Robert; McQuillan, Patrick M.
2016-01-01
Abstract The objective of this study was to evaluate the effect of hypothermic cardiopulmonary bypass (CPB) on cerebral oxygen saturation (rSO2), internal jugular bulb venous oxygen saturation (SjvO2), mixed venous oxygen saturation (SvO2), and bispectral index (BIS) used to monitor cerebral oxygen balance in pediatric patients. Sixty American Society of Anesthesiologists Class II-III patients aged 1 to 4 years old with congenital heart disease scheduled for elective cardiac surgery were included in this study. Temperature, BIS, rSO2, mean arterial pressure, central venous pressure, cerebral perfusion pressure (CPP), and hematocrit were recorded. Internal jugular bulb venous oxygen saturation and SvO2 were obtained from blood gas analysis at the time points: after induction of anesthesia (T0), beginning of CPB (T1), ascending aortic occlusion (T2), 20 minutes after initiating CPB (T3), coronary reperfusion (T4), separation from CPB (T5), and at the end of operation (T6). The effect of hypothermia or changes in CPP on rSO2, SjvO2, SvO2, and BIS were analyzed. Compared with postinduction baseline values, rSO2 significantly decreased at all-time points: onset of extracorporeal circulation, ascending aortic occlusion, 20 minutes after CPB initiation, coronary reperfusion, and separation from CPB (P < 0.05). Compared with measurements made following induction of anesthesia, SjvO2 significantly increased with initiation of CPB, ascending aortic occlusion, 20 minutes after initiating CPB, coronary reperfusion, and separation from CPB (P < 0.05). Compared with induction of anesthesia, BIS significantly decreased with the onset of CPB, aortic cross clamping, 20 minutes after initiating CPB, and coronary reperfusion (P < 0.05). Bispectral index increased following separation from CPB. There was no significant change in SvO2 during cardiopulmonary bypass (P > 0.05). Correlation analysis demonstrated that rSO2 was positively related to CPP (r = 0.687, P = 0.000), with a low linear correlation to temperature (r = 0.453, P = 0.000). Internal jugular bulb venous oxygen saturation was negatively related to temperature (r = −0.689, P = 0.000). Bispectral index was positively related to both temperature (r = 0.824, P = 0.000) and CPP (r = 0.782, P = 0.000). Cerebral oxygen saturation had a positive linear correlation with CPP and a low linear correlation to temperature. Internal jugular bulb venous oxygen saturation had a negative linear correlation to temperature. Pre-and and early postbypass periods are vulnerable times for adequate cerebral oxygenation. Anesthetic management must aim to optimize the supply and demand relationship. PMID:26765454
Hu, Zhiyong; Xu, Lili; Zhu, Zhirui; Seal, Robert; McQuillan, Patrick M
2016-01-01
The objective of this study was to evaluate the effect of hypothermic cardiopulmonary bypass (CPB) on cerebral oxygen saturation (rSO2), internal jugular bulb venous oxygen saturation (SjvO2), mixed venous oxygen saturation (SvO2), and bispectral index (BIS) used to monitor cerebral oxygen balance in pediatric patients.Sixty American Society of Anesthesiologists Class II-III patients aged 1 to 4 years old with congenital heart disease scheduled for elective cardiac surgery were included in this study. Temperature, BIS, rSO2, mean arterial pressure, central venous pressure, cerebral perfusion pressure (CPP), and hematocrit were recorded. Internal jugular bulb venous oxygen saturation and SvO2 were obtained from blood gas analysis at the time points: after induction of anesthesia (T0), beginning of CPB (T1), ascending aortic occlusion (T2), 20 minutes after initiating CPB (T3), coronary reperfusion (T4), separation from CPB (T5), and at the end of operation (T6). The effect of hypothermia or changes in CPP on rSO2, SjvO2, SvO2, and BIS were analyzed.Compared with postinduction baseline values, rSO2 significantly decreased at all-time points: onset of extracorporeal circulation, ascending aortic occlusion, 20 minutes after CPB initiation, coronary reperfusion, and separation from CPB (P < 0.05). Compared with measurements made following induction of anesthesia, SjvO2 significantly increased with initiation of CPB, ascending aortic occlusion, 20 minutes after initiating CPB, coronary reperfusion, and separation from CPB (P < 0.05). Compared with induction of anesthesia, BIS significantly decreased with the onset of CPB, aortic cross clamping, 20 minutes after initiating CPB, and coronary reperfusion (P < 0.05). Bispectral index increased following separation from CPB. There was no significant change in SvO2 during cardiopulmonary bypass (P > 0.05). Correlation analysis demonstrated that rSO2 was positively related to CPP (r = 0.687, P = 0.000), with a low linear correlation to temperature (r = 0.453, P = 0.000). Internal jugular bulb venous oxygen saturation was negatively related to temperature (r = -0.689, P = 0.000). Bispectral index was positively related to both temperature (r = 0.824, P = 0.000) and CPP (r = 0.782, P = 0.000). Cerebral oxygen saturation had a positive linear correlation with CPP and a low linear correlation to temperature. Internal jugular bulb venous oxygen saturation had a negative linear correlation to temperature.Pre-and and early postbypass periods are vulnerable times for adequate cerebral oxygenation. Anesthetic management must aim to optimize the supply and demand relationship.
USDA-ARS?s Scientific Manuscript database
Tallgrass prairie has been replaced by corn and soybeans and mixed-grass prairie is being replaced by various annual crops. Annual crop fields support vegetarian diets but not much wildlife. Alternatively, integrating pastured livestock farming with annual crops can provide wildlife habitat. For ...
Kou, S C; Lee, G; Poon, C S; Lai, W L
2009-02-01
This paper aims to investigate the fresh and hardened properties of lightweight aggregate concretes that are prepared with the use of recycled plastic waste sourced from scraped PVC pipes to replace river sand as fine aggregates. A number of laboratory prepared concrete mixes were tested, in which river sand was partially replaced by PVC plastic waste granules in percentages of 0%, 5%, 15%, 30% and 45% by volume. Two major findings are identified. The positive side shows that the concrete prepared with a partial replacement by PVC was lighter (lower density), was more ductile (greater Poisson's ratios and reduced modulus of elasticity), and had lower drying shrinkage and higher resistance to chloride ion penetration. The negative side reveals that the workability, compressive strength and tensile splitting strength of the concretes were reduced. The results gathered would form a part of useful information for recycling PVC plastic waste in lightweight concrete mixes.
Resilient modulus and the fatigue properties of Kansas hot mix asphalt mixes
DOT National Transportation Integrated Search
2006-08-01
A new design guide for pavement structures, based on a mechanistic design method, could be adopted by AASHTO in the near future and will replace the current version used by KDOT in the structural design of flexible and rigid pavements. The mechanisti...
Evaluation of a metering, mixing, and dispensing system for mixing polysulfide adhesive
NASA Technical Reports Server (NTRS)
Evans, Kurt B.
1989-01-01
Tests were performed to evaluate whether a metered mixing system can mix PR-1221 polysulfide adhesive as well as or better than batch-mixed adhesive; also, to evaluate the quality of meter-mixed PR-1860 and PS-875 polysulfide adhesives. These adhesives are candidate replacements for PR-1221 which will not be manufactured in the future. The following material properties were evaluated: peel strength, specific gravity and adhesive components of mixed adhesives, Shore A hardness, tensile adhesion strength, and flow rate. Finally, a visual test called the butterfly test was performed to observe for bubbles and unmixed adhesive. The results of these tests are reported and discussed.
Impact of Micro Silica on the properties of High Volume Fly Ash Concrete (HVFA)
NASA Astrophysics Data System (ADS)
Sripragadeesh, R.; Ramakrishnan, K.; Pugazhmani, G.; Ramasundram, S.; Muthu, D.; Venkatasubramanian, C.
2017-07-01
In the current situation, to overcome the difficulties of feasible construction, concrete made with various mixtures of Ordinary Portland Cement (OPC) and diverse mineral admixtures, is the wise choice for engineering construction. Mineral admixtures viz. Ground Granulated Blast Furnace Slag (GGBS), Meta kaolin (MK), Fly Ash (FA) and Silica Fume (SF) etc. are used as Supplementary Cementitious Materials (SCM) in binary and ternary blend cement system to enhance the mechanical and durability properties. Investigation on the effect of different replacement levels of OPC in M25 grade with FA + SF in ternary cement blend on the strength characteristics and beam behavior was studied. The OPC was partially replaced (by weight) with different combinations of SF (5%, 10%, 15%, 20% and 25%) and FA as 50% (High Volume Fly Ash - HVFA). The amount of FA addition is kept constant at 50% for all combinations. The compressive strength and tensile strength tests on cube and cylinder specimens, at 7 and 28 days were carried out. Based on the compressive strength results, optimum mix proportion was found out and flexural behaviour was studied for the optimum mix. It was found that all the mixes (FA + SF) showed improvement in compressive strength over that of the control mix and the mix with 50% FA + 10% SF has 20% increase over the control mix. The tensile strength was also increased over the control mix. Flexural behaviour also showed a significant improvement in the mix with FA and SF over the control mix.
Katsurada, K; Ogawa, M; Minami, T
1975-02-01
The present study was desined to clarify the roles of artificial hyperventilation in management of the patients with cerebral injury. Here reported is the first part of the serial studies and concerned with general informations about hyperventilation. The measurements of PaCO2, minute ventilation volume (VE), dead space (VD), tidal volume (VT), cardiac output (by dye dilution method), oxygen consumption (by Fick' principle) and oxygen equilibrium were performed in the patients suffering from acute, severe head injury. And the effect of assisted ventilation on them were investigated (using pressure-limited respirator). 1. There was a common finding that marked and sustained increase in VE, VA (alveolar ventilation), and decrease in PaCO2 existed during the first week of injury. 97% of both VE and VA were above normal and mean value of PaCO2 was 29-33 mmHg. The syndrome of spontaneous hyperventilation was evidently more prominent in the nonsurvived group of patients. It was noteworthy that increased VE (or VA) was dependent neither on VD or pulmonary dysfunction nor on metabolic acidosis of arterial blood. The relation of VA to base excess in head injury was well contrasted to that of acute CO poisoning. 2. Assisted ventilation resulted in increased VT and decreased respiratory rate, and little change in VE. Consequently, PaCO2 changed only from 33.0 to 29.4 mmHg as a mean of entire series of patients. But when the influence affected by hypoxemic drive was subsided, a significant reduction of PaCO2 was disclosed following assisted ventilation. The assisted ventilation with pure oxygen was also associated with reduced cardiac output (from 6.0l/min to 5.3l/min), though the oxygen consumption changed variedly among the patients. 3. The fact was confirmed that both hypocapnea and alkalosis produced the left-sised shift of oxygen dissociation curve, decrease in P50 (P02 at 50% saturation of oxygen), and in addition, narrowed arterio-mixed venous oxygen difference. The changes of artero-mixed venous oxygen saturation difference which were calculated at 100 mmHg of PaO2 and 40mmHg of mixed venous PO2 were in a linear fashion with those of P50. Apart from the problems on injured brain, the beneficial and non-beneficial effects of hyperventilation were further discussed. The availability and inidcation of artificial hyperventilation should be precisely evaluated later, in a comprehensive manner with the subsequent studies (Part 2 and 3) on cerebral metabolism and intracranial pressure.
Evaluation of fly ash concrete durability containing class II durability aggregates.
DOT National Transportation Integrated Search
1986-07-01
Fly ash was used in this evaluation study to replace 15% of the cement in : Class C-3 concrete paving mixes. One Class "c" ash from Iowa approved : sources was examined in each mix. Substitution rate was based on 1 to 1 : basis, for each pound of cem...
Properties of concrete containing foamed concrete block waste as fine aggregate replacement
NASA Astrophysics Data System (ADS)
Muthusamy, K.; Budiea, A. M. A.; Zaidan, A. L. F.; Rasid, M. H.; Hazimmah, D. S.
2017-11-01
Environmental degradation due to excessive sand mining dumping at certain places and disposal of foamed concrete block waste from lightweight concrete producing industry are issues that should be resolved for a better and cleaner environment of the community. Thus, the main intention of this study is to investigate the potential of foamed concrete block waste as partial sand replacement in concrete production. The foamed concrete waste (FCW) used in this research that were supplied by a local lightweight concrete producing industry. The workability and compressive strength of concrete containing various percentage of foamed concrete waste as partial sand replacement has been investigated. Prior to the use, the foamed concrete waste were crushed to produce finer particles. Six concrete mixes containing various content of crushed foamed concrete waste that are 0%, 10%, 20%, 30%, 40% and 50% were used in this experimental work. Then the prepared specimens were placed in water curing until the testing age. Compressive strength test and flexural strength tests were conducted at 7, 14 and 28 days. The result shows that integration of crushed foamed concrete waste as partial sand replacement in concrete reduces the mix workability. It is interesting to note that both compressive strength and flexural strength of concrete improves when 30% crushed foamed concrete waste is added as partial sand replacement.
Mixed Integer PDE Constrained Optimization for the Control of a Wildfire Hazard
2017-01-01
are nodes suitable for extinguishing the fire. We introduce a discretization of the time horizon [0, T] by the set of time T := {0, At,..., ntZ\\t = T...of the constraints and objective with a discrete counterpart. The PDE is replaced by a linear system obtained from a convergent finite difference...method [5] and the integral is replaced by a quadrature formula. The domain is discretized by replacing 17 with an equidistant grid of length Ax
Pistolesi, Valentina; Zeppilli, Laura; Polistena, Francesca; Sacco, Maria Itala; Pierucci, Alessandro; Tritapepe, Luigi; Regolisti, Giuseppe; Fiaccadori, Enrico; Morabito, Santo
2017-01-01
To evaluate the efficacy and safety of a commercially available phosphate-containing solution for continuous renal replacement therapy (CRRT) in preventing CRRT-related hypophosphatemia. In heart surgery patients undergoing continuous veno-venous haemodiafiltration (CVVHDF) with regional citrate anticoagulation (RCA), we combined an 18 mmol/l citrate solution with a phosphate-containing (1.2 mmol/l) dialysate/replacement fluid evaluating the incidence of hypophosphatemia and the need for parenteral phosphorus supplementation. In 75 patients on RCA-CVVHDF, the mean filter life was 53.9 ± 33.6 h. Regardless of baseline levels, phosphoremia was progressively corrected and maintained in a narrow normality range throughout RCA-CRRT days (after 72 h: 1.14 ± 0.25 mmol/l). Considering the whole CRRT period, 45 out of 975 (4.6%) serum phosphorus determinations met the criteria for mild (<0.81 mmol/l) or moderate (<0.61 mmol/l) hypophosphatemia; severe hypophosphatemia (<0.32 mmol/l) never occurred. After 72 h 88% of the patients were normophosphatemic, 9% hyperphosphatemic and 3% hypophosphatemic. RCA-CVVHDF with a phosphate-containing solution enabled the maintenance of phosphorus levels within normophosphatemic range in most of the patients, minimizing the occurrence of CRRT-related hypophosphatemia. © 2017 S. Karger AG, Basel.
Dabigatran etexilate versus warfarin as the oral anticoagulant of choice? A review of clinical data.
Ma, Terry K W; Yan, Bryan P; Lam, Yat-Yin
2011-02-01
For many years, warfarin was the only effective oral anticoagulant to prevent and treat thromboembolism. Nevertheless, its clinical use is limited by a narrow therapeutic window, extensive drug interactions, need of strict dietary control and frequent monitoring. The pharmacological response is also unpredictable and highly variable among patients. Suboptimal anticoagulation can lead to detrimental thromboembolic events or life-threatening bleeding. Direct thrombin inhibitor (DTI) activity represents a new class of anticoagulant activity that was intended to replace warfarin. Ximelagatran was the first DTI shown to have similar efficacy to warfarin, but failed to replace it because of a high incidence of liver toxicity. Dabigatran etexilate is another novel DTI with a more predictable pharmacokinetic profile and fewer drug interactions compared with warfarin. Recent large-scaled, randomized studies have shown that it does not share ximelagatran's hepatotoxicity, and is as effective as conventional anticoagulants for venous thromboembolism (VTE) and prophylaxis in atrial fibrillation (AF). These findings led to the approval of dabigatran etexilate for thromboprophylaxis following hip or knee replacement surgery in Europe, Canada and the United Kingdom. Here we summarize the latest evidence concerning the use of dabigatran etexilate in VTE (BISTRO, RE-MODEL, RE-NOVATE, RE-MOBILIZE and RECOVER) and AF (PETRO and RELY). Potential problems related to dabigatran use are also discussed to examine whether it can truly replace warfarin as the gold standard. Copyright © 2010 Elsevier Inc. All rights reserved.
Palmer, Kenneth; Ridgway, Tim; Al-Rawi, Omar; Johnson, Ian; Poullis, Michael
2011-09-01
Some patients have short intensive care stay periods and little or no organ dysfunction after cardiac surgery and others do not despite seemingly faultless surgery, perfusion, and anesthesia. These "unknown" reasons for death and morbidity usually relate to organ ischemia and inflammation, but are obviously mutlifactorial. A Lissajous figure is a technique in electrical engineering to compare two different electrical signals. We utilize this basic concept in a very simple manner to potentially identify why some of these unknown deaths or morbidities occur. Utilizing an electronic perfusion database, we retrospectively analyzed 43 patients undergoing aortic surgery with regard to central venous saturations during cooling and rewarming. Isolated aortic valve replacement patients were excluded. Central venous saturation, time, and temperature were plotted to create a Lissajous figure for the whole operation, and during cooling and rewarming separately. Temperature and saturations were analyzed every 20 seconds. Perfusion related variables were registered and uploaded to www.perfsort.net. Lissajous figures during cooling add little to patient care due to their similarity. Isolated rewarming revealed startling differences. It is immediately visually obvious who had short and long periods of tissue ischemia and reperfusion during rewarming in a seemingly uneventful operation. The periods of ischemia can be semi quantified into: none, mild, moderate, and severe. Creation of simple Lissajous figures during rewarming for bypass runs may be an additional helpful tool in root cause analysis of patient death/morbidity when surgery, perfusion, and anesthesia seemed faultless. Low central venous saturations at hypothermic temperatures mean significant metabolic activity, indicating tissue ischemia is occurring. Further work is needed to correlate this concept to outcomes.
Percutaneous Endovascular Salvage Techniques for Implanted Venous Access Device Dysfunction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breault, Stéphane, E-mail: stephane.breault@chuv.ch; Glauser, Frédéric, E-mail: frederic.glauser@chuv.ch; Babaker, Malik, E-mail: malik.babaker@chuv.ch
2015-06-15
PurposeImplanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques.Methods and MaterialsThrough a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new “mechanical adhesiolysis”more » maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication.ResultsEighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted.ConclusionThese IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.« less
Baek, Jin Hyen; Yalamanoglu, Ayla; Moon, So-Eun; Gao, Yamei; Buehler, Paul W
2018-03-01
Red blood cell (RBC) oxygen (O 2 ) delivery may be impacted at the tissue, cellular, and molecular levels after storage duration, preservation strategies, and pathogen reduction. Collectively, the preclinical measurement of arterial and venous PO 2 , systemic blood flow, tissue hypoxia-inducible factors (HIFs), pimonidazole adduction, and erythropoietin (EPO) regulation can serve to elucidate differential RBC quality after storage and processing. Donor guinea pig blood was collected, leukoreduced, and stored at 4°C in AS-3 for 1 (fresh) or 14 (stored) days. RBC variables-2,3-diphosphoglycerate, adenosine triphosphate, hemoglobin, morphology, deformability, and in vivo recovery at 24 hours-were measured at each storage duration. Recipient guinea pigs were exchange transfused until 80% volume replacement was achieved. Arterial and venous blood gases, systemic blood flow, renal HIF-1α and HIF-2α, renal EPO mRNA, plasma EPO, and renal tissue pimonidazole adduction were measured after transfusion. RBC variables declined significantly with storage; however, hemolysis and in vivo recovery remained within the allowable limits for human blood storage. Posttransfusion arterial and venous PO 2 and systemic blood flow decreased, and renal HIFs, EPO mRNA, and pimonidazole adducts increased. Subsequently, EPO accumulated in plasma indicating decreased O 2 availability in the kidneys. Conversely, all variables remained at basal levels in the fresh blood group. The evaluation of renal O 2 homeostasis after transfusion represents an effective approach to defining RBC quality between predicate and novel processing. Methods are adapted from standardized techniques and ideal for preclinical evaluation. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Granero, J; Díaz de Rada, P; Lozano, L M; Martínez, J; Herrera, A
2016-01-01
To analyse the effectiveness and safety of rivaroxaban vs. standard treatment (ST) in the prevention of venous thromboembolism after hip or knee replacement in daily clinical practice in Spain. A sub-analysis of the Spanish data in the XAMOS international observational study that included patients>18 years who received 10mg o.d. rivaroxaban or ST. up to 3 months after surgery. incidence of symptomatic/asymptomatic thromboembolic events, bleeding, mortality, and other adverse events; use of health resources and satisfaction after hospital discharge. Of the total 801 patients included, 410 received rivaroxaban and 391 ST (64.7% heparin, 24.0% fondaparinux, 11% dabigatran). The incidence of symptomatic thromboembolic events and major bleeding was similar in both groups (0.2% vs. 0.8% wit ST and 0.7% vs. 1.3% with ST [EMA criteria]/0.0% vs. 0.3% with ST [RECORD criteria]). The adverse events incidence associated with the drug was significantly higher rivaroxaban (overall: 4.4% vs. 0.8% with ST, P=.001; serious: 1.5% vs. 0.0% with ST, P=.03). The rivaroxaban used less health resources after discharge, and the majority considered the tolerability as «very good« and the treatment as «very comfortable». Rivaroxaban is at least as effective as ST in the prevention of venous thromboembolism prevention in daily clinical practice, with a similar incidence of haemorrhages. It provides greater satisfaction/comfort, and less health resources after discharge. These results should be interpreted taking into account the limitations inherent in observational studies. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Kankirawatana, Suthida; Huang, Shu T; Marques, Marisa B
2007-01-01
While therapeutic plasma exchanges (TPEs) performed with 5% albumin are considered safe, concerns regarding venous access and hypocalcemic toxicity remain. We reviewed the frequency of complications during TPEs performed with 5% albumin supplemented with calcium gluconate and potassium chloride for a 5 year period in our institution. Eighty-four adult patients (46 males and 38 females) underwent 581 plasma exchanges during the study period. The most common indications were myasthenia gravis (37%), acute inflammatory demyelinating polyradiculoneuropathy (31%), and chronic inflammatory demyelinating polyneuropathy (13%). All procedures used 2.2% ACD-A delivered at a calculated average rate of 0.26 mg/kg/min, which led to a mean dose of citrate per TPE of 2.18 +/- 0.48 g or 27.8 +/- 5.24 mg/kg of body weight. Venous access difficulties occurred in 85 procedures (14.6%), but most TPEs were completed successfully. Hypotension and citrate toxicity were seen in <5% of the TPEs and were mostly reversible. Only 17 exchanges (3%) had to be aborted because of the loss of venous access (n = 9), hypocalcemic toxicity (n = 3), hypotension (n = 2), panic attacks (n = 2), and one atypical reaction due to the interaction with an angiotensin converting enzyme inhibitor. Comparison between pre- and post-TPE potassium levels showed a statistically significant mean decrease of 7%, from 4.1 mequiv/l to 3.8 mequiv/l (P < 0.0001). We attribute the low rate of hypocalcemia to our practice of adding calcium and potassium to the replacement fluid and suggest that this method could become standard of care. Copyright 2007 Wiley-Liss, Inc.
Pre-hospital haemostatic dressings: a systematic review.
Granville-Chapman, J; Jacobs, N; Midwinter, M J
2011-05-01
Uncontrolled haemorrhage is a leading cause of prehospital death after military and civilian trauma. Exsanguination from extremity wounds causes over half of preven military combat deaths and wounds to the anatomical junctional zones provide a particular challenge for first responders. Commercial products have been developed, which claim to outperform standard gauze bandages in establishing and maintaining non-surgical haemostasis. Since 2004, two advanced haemostatic dressing products, HemCon and QuikClot have been widely deployed in military operations. Newer products have since become available which aim to provide more efficient haemostasis than and thus supersede HemCon and QuikClot. To conduct a systematic review of clinical and preclinical evidence to compare the relative efficacy and safety of available haemostatic products, which are of relevance to pre-hospital military and civilian emergency medical providers. An English language literature search was performed, using PubMed and Web of Knowledge Databases, with cross-referencing, focussed product searches and communication with product manufacturers. For studies employing animal models, the injury model was required to produce fatal haemorrhage. Products were categorised by primary mode of action as either factor concentrators,mucoadhesive agents or procoagulant supplementors. From 60 articles collated, 6 clinical papers and 37 preclinical animal trials were eligible for inclusion in this review. Products have been tested in three different types of haemorrhage model: low pressure, high volume venous bleeding, high pressure arterial bleeding and mixed arterial-venous bleeding. The efficacy of products varies with the model adopted. Criteria for the 'ideal battle field haemostatic dressing' have previously been defined by Pusateri, but no product has yet attained suchstatus. Since 2004, HemCon (a mucoadhesive agent) and QuikClot (a factor concentrator) have been widely deployed by United States and United Kingdom Armed Forces; retrospective clinical data supports their efficacy. However, in some recent animal models of lethal haemorrhage, WoundStat(mucoadhesive), Celox (mucoadhesive) and CombatGauze (procoagulant supplementor) have all outperformed both HemCon and QuikClot products. HemCon and QuikClot have augmented the haemostatic capabilities of the military first aid responder, but newer products demonstrate potential to be more effective and should be considered as replacements for current in service systems. These products could have utility for civilian pre-hospital care. 2010 Elsevier Ltd. All rights reserved.
Cavopulmonary support with a microaxial pump for the failing Fontan physiology.
Zhu, Jiaquan; Kato, Hideyuki; Fu, Yaqin Y; Zhao, Lisa; Foreman, Celeste; Davey, Lisa; Weisel, Richard D; Van Arsdell, Glen S; Honjo, Osami
2015-01-01
The number of patients with the failing Fontan physiology is increasing. We tested a novel in situ microaxial pump (Impella) to support the failing atrio-pulmonary Fontan circulation in an acute pig model. A Fontan model was established in eight juvenile pigs by connecting the right atrium to the main pulmonary artery after tricuspid valve destruction. The Impella pump was inserted retrograde from the distal main pulmonary artery into the right atrium. Hemodynamics, blood gas, and echocardiographic data were compared among baseline, pure Fontan physiology (10 minutes), and mechanically assisted Fontan physiology (up to 12 hours). The Impella system generated a blood flow of 75-85 ml/kg/minute in six animals, and 55-65 ml/kg/minute in two animals. The mechanically assisted Fontan attained a significantly higher mean blood pressure (39.6 ± 7 vs. 24.7 ± 3.3 mm Hg, p < 0.01), lower central venous pressure (5 ± 2.4 vs. 12.8 ± 1.7 mm Hg, p < 0.01), and higher mixed venous saturation (60.4 ± 10.8 vs. 23.4 ± 8.4 mm Hg, p < 0.01) compared with pure Fontan physiology. Cardiac output and stroke volume were similar during baseline and mechanically assisted Fontan (p = not significant). This acute pig study demonstrated the feasibility of mechanical circulatory support in the failing Fontan physiology. The in situ microaxial pump maintained cardiac output while increasing blood pressure and reducing venous pressure.
Nanda, Sunil Kumar; Ray, Lopamudra; Dinakaran, Asha
2015-02-01
Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be measured in arterial blood within 5 min. This study was done to study the agreement of arterial sodium and arterial potassium with venous sodium and venous potassium levels. Venous sodium and venous potassium levels and arterial sodium and arterial potassium levels were analysed on 206 patient samples admitted to Intensive Care Unit (ICU). The venous values were compared with the arterial values for correlation. Venous sodium was compared with arterial sodium by spearman correlation. Venous potassium was compared with arterial potassium by pearson correlation. The mean value of arterial sodium was 134 and venous sodium was 137. The mean value of arterial potassium was 3.6 and venous potassium was 4.1. The correlation coefficient obtained for sodium was 0.787 and correlation coefficient obtained for potassium was 0.701. There was positive correlation of arterial sodium and arterial potassium with venous sodium and venous potassium indicating agreement between the parameters. Arterial sodium and arterial potassium can be used instead of venous sodium and venous potassium levels in management of critically ill patients.
Infrastructure Requirements for an Urgent-Start Peritoneal Dialysis Program
Ghaffari, Arshia; Kumar, Vijay; Guest, Steven
2013-01-01
Patients with advanced chronic kidney disease nearing dialysis but without pre-established access almost uniformly initiate dialysis with a temporary central venous catheter. These catheters are associated with high rates of infection and flow disturbances, requiring removal and subsequent replacement. Many of these patients might be candidates for peritoneal dialysis (PD), but because of the absence of prior catheter placement, the default initial modality is hemodialysis. Recent reports, however, have demonstrated the feasibility of initiating PD urgently despite the late referral for access placement. Urgent-start PD clinical pathways require a unique infrastructure and treatment approach. This article reviews the salient features required to establish an urgent-start PD program. PMID:24335123
Boldt, Joachim; Suttner, Stephan; Brosch, Christian; Lehmann, Andreas; Röhm, Kerstin; Mengistu, Andinet
2009-03-01
A balanced fluid replacement strategy appears to be promising for correcting hypovolemia. The benefits of a balanced fluid replacement regimen were studied in elderly cardiac surgery patients. In a randomized clinical trial, 50 patients aged >75 years undergoing cardiac surgery received a balanced 6% HES 130/0.42 plus a balanced crystalloid solution (n = 25) or a non-balanced HES in saline plus saline solution (n = 25) to keep pulmonary capillary wedge pressure/central venous pressure between 12-14 mmHg. Acid-base status, inflammation, endothelial activation (soluble intercellular adhesion molecule-1, kidney integrity (kidney-specific proteins glutathione transferase-alpha; neutrophil gelatinase-associated lipocalin) were studied after induction of anesthesia, 5 h after surgery, 1 and 2 days thereafter. Serum creatinine (sCr) was measured approximately 60 days after discharge. A total of 2,750 +/- 640 mL of balanced and 2,820 +/- 550 mL of unbalanced HES were given until the second POD. Base excess (BE) was significantly reduced in the unbalanced (from +1.21 +/- 0.3 to -4.39 +/- 1.0 mmol L(-1) 5 h after surgery; P < 0.001) and remained unchanged in the balanced group (from 1.04 +/- 0.3 to -0.81 +/- 0.3 mmol L(-1) 5 h after surgery). Evolution of the BE was significantly different. Inflammatory response and endothelial activation were significantly less pronounced in the balanced than the unbalanced group. Concentrations of kidney-specific proteins after surgery indicated less alterations of kidney integrity in the balanced than in the unbalanced group. A total balanced volume replacement strategy including a balanced HES and a balanced crystalloid solution resulted in moderate beneficial effects on acid-base status, inflammation, endothelial activation, and kidney integrity compared to a conventional unbalanced volume replacement regimen.
Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis
2014-10-09
Renal Failure Chronic Requiring Hemodialysis; Central Venous Catheterization; Inadequate Hemodialysis Blood Flow; Venous Stenosis; Venous Thrombosis; Infection Due to Central Venous Catheter; Central Venous Catheter Thrombosis
Evaluation of fly ash in water reduced paving mixtures.
DOT National Transportation Integrated Search
1985-06-01
Fly ash was used to replace 15% of the cement in C3WR and C6WR concrete : paving mixes containing ASTM C494 Type A water reducin9 admixtures. Two Class : C ashes and one Class F ash from Iowa approved sources were examined in each : mix. When Class C...
Quan, Reagan W; Gillespie, David L; Stuart, Rory P; Chang, Audrey S; Whittaker, David R; Fox, Charles J
2008-03-01
The management of venous trauma remains controversial. Critics of venous repair have cited an increased incidence of associated venous thromboembolic events with this management. We analyzed the current treatment of wartime venous injuries in United States military personnel in an effort to answer this question. From December 1, 2001, to October 31, 2005, all United States casualties with named venous injuries were evaluated. A retrospective review of a clinical database was performed on demographics, mechanism of injury, associated injuries, treatment, outcomes, and venous thromboembolic events. Data were analyzed using the Fisher exact test, analysis of variance, and logarithmic transformation. During this 5-year period, 82 patients sustained 103 named venous injuries due to combat operations. All patients were male, with an average age of 27.9 years (range, 20.3-58.3 years). Blast injuries accounted for 54 venous injuries (65.9%), gunshot wounds for 25 (30.5%), and motor vehicle accidents for 3 (3.6%). The venous injury was isolated in 28 patients (34.1%), and 16 (19.5%) had multiple venous injuries. The venous injury in two patients was associated with acute phlegmasia, with fractures in 33 (40.2%), and 22 (28.1%) sustained neurologic deficits. Venous injuries were treated by ligation in 65 patients (63.1%) and by open surgical repair in 38 (36.9%). Postoperative extremity edema occurred in all patients irrespective of method of management. Thrombosis after venous repair occurred in six of the 38 cases (15.8%). Pulmonary emboli developed in three patients, one after open repair and two after ligation (P > .99). In the largest review of military venous trauma in more than three decades, we found no difference in the incidence of venous thromboembolic complications between venous injuries managed by open repair vs ligation. Blast injuries of the extremities have caused most of the venous injuries. Ligation is the most common modality of treatment in combat zones. Long-term morbidity associated with venous injuries and their management will be assessed in future follow-up studies.
Braithwaite, Irene; Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette
2017-02-01
We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Randomized controlled trial. Twenty-four healthy participants aged 18-54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Pacific Radiology, Lower Hutt, Wellington. The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was -0.8 (-6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility.
Coquin, Julien; Dewitte, Antoine; Manach, Yannick Le; Caujolle, Marie; Joannes-Boyau, Olivier; Fleureau, Catherine; Janvier, Gérard; Ouattara, Alexandre
2012-09-01
Measurement of total hemoglobin, based on pulse co-oximetry, is a continuous and noninvasive method that has been principally evaluated in healthy volunteers subjected to hemodilution. We tested the hypothesis that its accuracy could adversely affect patients presenting with severe hemorrhage, which is traditionally associated with increased microvascular tone. Observational study. Twelve-bed mixed medico-surgical intensive care unit. Thirty-three patients admitted to our critical care unit for gastrointestinal bleeds were included. A spectrophotometric sensor was positioned on the patient's fingertip and connected to a pulse co-oximeter. During the first 24 hrs following admission, venous hemoglobin level was determined at the laboratory every 8 hrs and was compared with hemoglobin levels displayed on the pulse co-oximeter measurements screen and/or measured from capillary blood using a portable photometer. The primary end point was the percentage of inaccurate measurements, which were defined as >15% difference compared with reference values or their unavailability for any technical reason. Twenty-five (19%) measurements of pulse co-oximeter measurements were unavailable from the screen. Pulse co-oximeter measurements and capillary hemoglobin levels were significantly correlated to venous hemoglobin level. For venous hemoglobin level compared with pulse co-oximeter measurements (n = 105), and for venous hemoglobin level compared with capillary hemoglobin levels (n = 111), the biases were, respectively, 1.0 ± 1.9 g dL and 0.4 ± 1.0 g dL (p < .05). The proportion of inaccurate measurements was significantly higher for pulse co-oximeter measurements (56% vs. 15%, p < .05). Although the use of norepinephrine did not affect concordance parameters, unavailability of measurements was frequently observed (42% vs. 15%, p < .05). Determination of pulse co-oximetry-based hemoglobin in patients presenting with severe gastrointestinal bleeds can be inaccurate, which renders its use to guide transfusion decisions potentially hazardous. The unavailability of measurements, especially during vasopressor infusion, represents another serious limitation for hemorrhagic patients.
Glass, Todd F; Knapp, Jason; Amburn, Philip; Clay, Bruce A; Kabrisky, Matt; Rogers, Steven K; Garcia, Victor F
2004-02-01
To determine whether a prototype artificial intelligence system can identify volume of hemorrhage in a porcine model of controlled hemorrhagic shock. Prospective in vivo animal model of hemorrhagic shock. Research foundation animal surgical suite; computer laboratories of collaborating industry partner. Nineteen, juvenile, 25- to 35-kg, male and female swine. Anesthetized animals were instrumented for arterial and systemic venous pressure monitoring and blood sampling, and a splenectomy was performed. Following a 1-hr stabilization period, animals were hemorrhaged in aliquots to 10, 20, 30, 35, 40, 45, and 50% of total blood volume with a 10-min recovery between each aliquot. Data were downloaded directly from a commercial monitoring system into a proprietary PC-based software package for analysis. Arterial and venous blood gas values, glucose, and cardiac output were collected at specified intervals. Electrocardiogram, electroencephalogram, mixed venous oxygen saturation, temperature (core and blood), mean arterial pressure, pulmonary artery pressure, central venous pressure, pulse oximetry, and end-tidal CO(2) were continuously monitored and downloaded. Seventeen of 19 animals (89%) died as a direct result of hemorrhage. Stored data streams were analyzed by the prototype artificial intelligence system. For this project, the artificial intelligence system identified and compared three electrocardiographic features (R-R interval, QRS amplitude, and R-S interval) from each of nine unknown samples of the QRS complex. We found that the artificial intelligence system, trained on only three electrocardiographic features, identified hemorrhage volume with an average accuracy of 91% (95% confidence interval, 84-96%). These experiments demonstrate that an artificial intelligence system, based solely on the analysis of QRS amplitude, R-R interval, and R-S interval of an electrocardiogram, is able to accurately identify hemorrhage volume in a porcine model of lethal hemorrhagic shock. We suggest that this technology may represent a noninvasive means of assessing the physiologic state during and immediately following hemorrhage. Point of care application of this technology may improve outcomes with earlier diagnosis and better titration of therapy of shock.
Pulmonary physiology during pulmonary embolism.
Elliott, C G
1992-04-01
Acute pulmonary thromboembolism produces a number of pathophysiologic derangements of pulmonary function. Foremost among these alterations is increased pulmonary vascular resistance. For patients without preexistent cardiopulmonary disease, increased pulmonary vascular resistance is directly related to the degree of vascular obstruction demonstrated on the pulmonary arteriogram. Vasoconstriction, either reflexly or biochemically mediated, may contribute to increased pulmonary vascular resistance. Acute pulmonary thromboembolism also disturbs matching of ventilation and blood flow. Consequently, some lung units are overventilated relative to perfusion (increased dead space), while other lung units are underventilated relative to perfusion (venous admixture). True right-to-left shunting of mixed venous blood can occur through the lungs (intrapulmonary shunt) or across the atrial septum (intracardiac shunt). In addition, abnormalities of pulmonary gas exchange (carbon monoxide transfer), pulmonary compliance and airway resistance, and ventilatory control may accompany pulmonary embolism. Thrombolytic therapy can reverse the hemodynamic derangements of acute pulmonary thromboembolism more rapidly than anticoagulant therapy. Limited data suggest a sustained benefit of thrombolytic treatment on the pathophysiologic alterations of pulmonary vascular resistance and pulmonary gas exchange produced by acute pulmonary emboli.
Patterns and Rates of Supplementary Venous Drainage to the Internal Jugular Veins.
Qureshi, Adnan I; Ishfaq, Muhammad Fawad; Herial, Nabeel A; Khan, Asif A; Suri, M Fareed K
2016-07-01
Several studies have found supplemental venous drainage channels in addition to bilateral internal jugular veins for cerebral venous efflux. We performed this study to characterize the supplemental venous outflow patterns in a consecutive series of patients undergoing detailed cerebral angiography with venous phase imaging. The venographic phase of the arteriogram was reviewed to identify and classify supplemental cerebral venous drainage into anterior (cavernous venous sinus draining into pterygoid plexus and retromandibular vein) and posterior drainage pattern. The posterior drainage pattern was further divided into plexiform pattern (with sigmoid venous sinus draining into the paravertebral venous plexus), and solitary vein pattern (dominant single draining deep cervical vein) drainage. The posterior plexiform pattern was further divided into 2 groups: posterior plexiform with or without prominent solitary vein. Supplemental venous drainage was seen ipsilateral to internal jugular vein in 76 (43.7%) of 174 venous drainages (87 patients) analyzed. The patterns were anterior (n = 23, 13.2%), posterior plexiform without prominent solitary vein (n = 40, 23%), posterior plexiform with prominent solitary vein (n = 62, 35.6%), and posterior solitary vein alone (n = 3, 1.7%); occipital emissary veins and/or transosseous veins were seen in 1 supplemental venous drainage. Concurrent ipsilateral anterior and posterior supplemental drainage was seen in 6 of 174 venous drainages analyzed. We provide an assessment of patterns and rates of supplementary venous drainage to internal jugular veins to improve our understanding of anatomical and physiological aspects of cerebral venous drainage. Copyright © 2016 by the American Society of Neuroimaging.
The possibility for use of venous flaps in plastic surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.
2015-11-17
The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were nomore » differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.« less
Medial gastrocnemius vein aneurysm development after compressive trauma in the knee.
De Santis, Francesco; Candia, Silvia; Scialpi, Renzo; Piccinin, Alfredo; Bruni, Antonio; Morettini, Giuseppe; Loreni, Giorgio
2017-06-01
Objectives Venous aneurysms are uncommon. They can involve both superficial and deep venous systems. We hereby present a unique case of gastrocnemius venous aneurysm developed after compressive knee trauma. Report A large venous aneurysm in the left popliteal fossa was detected by chance in a 44-year-old woman one month after a compressive trauma to the posterior surface of the knee. Magnetic resonance-imaging of the same knee had documented normal venous anatomy one year earlier. The venous aneurysm involved the medial gastrocnemius vein near its confluence in the popliteal vein and was surgically resected. Histopathology evidenced a true venous aneurysm. The patient was discharged under oral anticoagulation for three months. At one year follow-up, neither complications nor new venous aneurysm development was detected. Conclusions An accurate evaluation of the venous system is always mandatory after limb traumas which may lead to post-traumatic venous pseudo-aneurysms, as well as more rarely, true venous aneurysms in the lower extremities.
Seghir, A; Boucherit-Otmani, Z; Boucherit, K; Sari-Belkharroubi, L; Anselme-Bertrand, I
2015-06-01
Mixed-species biofilms constitute a reservoir of infection for a group of bacteria and yeasts that coexist on the same support. Peripheral venous catheters make up a good surface for the attachment of microorganisms that promote biofilm formation and this requires complex strategies for antimicrobial treatments. No such studies on formation mixed biofilms have ever been conducted in Algeria. Therefore, we evaluated the potential for the formation of mixed-species biofilms by Candida albicans and some bacterial species isolated from peripheral vascular catheters at the University Hospital of Tlemcen, in Algeria. The results obtained showed that C. albicans have the potential to form mixed biofilms with three bacteria (Enterobacter cloacae, Bordetella spp. and Serratia liquefaciens) isolated from the same catheter as the yeasts. The amount of biofilms produced varies depending on the species and the composition of the growth medium. Observations by scanning electron microscopy showed that the structure of the mixed biofilm depends on the surface support the biofilm was formed on, and varies with the species. A competition was noted between bacteria and yeasts; it depends on the composition of the medium and its pH, which both play an important role in promoting the dominance of one over the other. Copyright © 2015. Published by Elsevier Masson SAS.
Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage
ERIC Educational Resources Information Center
Shen, Tao; Baker, Keith
2015-01-01
Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…
Use of selected waste materials in concrete mixes.
Batayneh, Malek; Marie, Iqbal; Asi, Ibrahim
2007-01-01
A modern lifestyle, alongside the advancement of technology has led to an increase in the amount and type of waste being generated, leading to a waste disposal crisis. This study tackles the problem of the waste that is generated from construction fields, such as demolished concrete, glass, and plastic. In order to dispose of or at least reduce the accumulation of certain kinds of waste, it has been suggested to reuse some of these waste materials to substitute a percentage of the primary materials used in the ordinary portland cement concrete (OPC). The waste materials considered to be recycled in this study consist of glass, plastics, and demolished concrete. Such recycling not only helps conserve natural resources, but also helps solve a growing waste disposal crisis. Ground plastics and glass were used to replace up to 20% of fine aggregates in concrete mixes, while crushed concrete was used to replace up to 20% of coarse aggregates. To evaluate these replacements on the properties of the OPC mixes, a number of laboratory tests were carried out. These tests included workability, unit weight, compressive strength, flexural strength, and indirect tensile strength (splitting). The main findings of this investigation revealed that the three types of waste materials could be reused successfully as partial substitutes for sand or coarse aggregates in concrete mixtures.
Effect of unground oil palm ash as mixing ingredient towards properties of concrete
NASA Astrophysics Data System (ADS)
Sulaiman, M. A.; Muthusamy, K.; Mat Aris, S.; Rasid, M. H. Mohd; Paramasivam, R.; Othman, R.
2018-04-01
Malaysia being one of the world largest palm oil producers generates palm oil fuel ash (POFA), a by-product in increasing quantity. This material which usually disposed as solid waste causes pollution to the environment. Success in converting this waste material into benefitting product would reduce amount of waste disposed and contributes towards cleaner environment. This research explores the potential of unground oil palm ash being used as partial sand replacement in normal concrete production. Experimental work has been conducted to determine the workability, compressive strength and flexural strength of concrete when unground oil palm ash is added as partial sand replacement. A total of five mixes containing various percentage of oil palm ash, which are 0%, 5%, 10%, 15% and 20% have been prepared. All specimens were water cured until the testing date. The slump test, compressive strength test and flexural strength test was conducted. The findings show that mix produced using 10% of palm oil fuel ash exhibit higher compressive strength and flexural strength as compared to control specimen. Utilization of unground oil palm ash as partial sand replacement would be able to reduce dependency of construction industry on natural sand supply and also as one of the solution to reuse palm oil industry waste.
Cerebral Microcirculation during Experimental Normovolaemic Anemia
Bellapart, Judith; Cuthbertson, Kylie; Dunster, Kimble; Diab, Sara; Platts, David G.; Raffel, O. Christopher; Gabrielian, Levon; Barnett, Adrian; Paratz, Jenifer; Boots, Rob; Fraser, John F.
2016-01-01
Anemia is accepted among critically ill patients as an alternative to elective blood transfusion. This practice has been extrapolated to head injury patients with only one study comparing the effects of mild anemia on neurological outcome. There are no studies quantifying microcirculation during anemia. Experimental studies suggest that anemia leads to cerebral hypoxia and increased rates of infarction, but the lack of clinical equipoise, when testing the cerebral effects of transfusion among critically injured patients, supports the need of experimental studies. The aim of this study was to quantify cerebral microcirculation and the potential presence of axonal damage in an experimental model exposed to normovolaemic anemia, with the intention of describing possible limitations within management practices in critically ill patients. Under non-recovered anesthesia, six Merino sheep were instrumented using an intracardiac transeptal catheter to inject coded microspheres into the left atrium to ensure systemic and non-chaotic distribution. Cytometric analyses quantified cerebral microcirculation at specific regions of the brain. Amyloid precursor protein staining was used as an indicator of axonal damage. Animals were exposed to normovolaemic anemia by blood extractions from the indwelling arterial catheter with simultaneous fluid replacement through a venous central catheter. Simultaneous data recording from cerebral tissue oxygenation, intracranial pressure, and cardiac output was monitored. A regression model was used to examine the effects of anemia on microcirculation with a mixed model to control for repeated measures. Homogeneous and normal cerebral microcirculation with no evidence of axonal damage was present in all cerebral regions, with no temporal variability, concluding that acute normovolaemic anemia does not result in short-term effects on cerebral microcirculation in the ovine brain. PMID:26869986
Smith, Orla M; Wald, Ron; Adhikari, Neill K J; Pope, Karen; Weir, Matthew A; Bagshaw, Sean M
2013-10-05
Acute kidney injury is a common and devastating complication of critical illness, for which renal replacement therapy is frequently needed to manage severe cases. While a recent systematic review suggested that "earlier" initiation of renal replacement therapy improves survival, completed trials are limited due to small size, single-centre status, and use of variable definitions to define "early" renal replacement therapy initiation. This is an open-label pilot randomized controlled trial. One hundred critically ill patients with severe acute kidney injury will be randomly allocated 1:1 to receive "accelerated" initiation of renal replacement therapy or "standard" initiation at 12 centers across Canada. In the accelerated arm, participants will have a venous catheter placed and renal replacement therapy will be initiated within 12 hours of fulfilling eligibility. In the standard initiation arm, participants will be monitored over 7 days to identify indications for renal replacement therapy. For participants in the standard arm with persistent acute kidney injury, defined as a serum creatinine not declining >50% from the value at the time of eligibility, the initiation of RRT will be discouraged unless one or more of the following criteria are fulfilled: serum potassium ≥6.0 mmol/L; serum bicarbonate ≤10 mmol/L; severe respiratory failure (PaO₂/FiO₂<200) or persisting acute kidney injury for ≥72 hours after fulfilling eligibility. The inclusion criteria are designed to identify a population of critically ill adults with severe acute kidney injury who are likely to need renal replacement therapy during their hospitalization, but not immediately. The primary outcome is protocol adherence (>90%). Secondary outcomes include measures of feasibility (proportion of eligible patients enrolled in the trial, proportion of enrolled patients followed to 90 days for assessment of vital status and the need for renal replacement therapy) and safety (occurrence of adverse events). The optimal timing of renal replacement therapy initiation in patients with severe acute kidney injury remains uncertain, representing an important knowledge gap and a priority for high-quality research. This pilot trial is necessary to establish protocol feasibility, confirm the safety of participants and obtain estimated events rates for design of a large definitive trial. NCT01557361.
Czihal, M; Paul, S; Rademacher, A; Bernau, C; Hoffmann, U
2015-03-01
To explore the association of the postthrombotic syndrome with venous hemodynamics and morphological abnormalities after upper extremity deep venous thrombosis. Thirty-seven patients with a history of upper extremity deep venous thrombosis treated with anticoagulation alone underwent a single study visit (mean time after diagnosis: 44.4 ± 28.1 months). Presence and severity postthrombotic syndrome were classified according to the modified Villalta score. Venous volume and venous emptying were determined by strain-gauge plethysmography. The arm veins were assessed for postthrombotic abnormalities by ultrasonography. The relationship between postthrombotic syndrome and hemodynamic and morphological sequelae was evaluated using univariate significance tests and Spearman's correlation analysis. Fifteen of 37 patients (40.5%) developed postthrombotic syndrome. Venous volume and venous emptying of the arm affected by upper extremity deep venous thrombosis did not correlate with the Villalta score (rho = 0.17 and 0.19; p = 0.31 and 0.25, respectively). Residual morphological abnormalities, as assessed by ultrasonography, did not differ significantly between patients with and without postthrombotic syndrome (77.3% vs. 86.7%, p = 0.68). Postthrombotic syndrome after upper extremity deep venous thrombosis is not associated with venous hemodynamics or residual morphological abnormalities. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Çildağ, Mehmet B; Ertuğrul, Mustafa B; Köseoğlu, Ömer Fk; Armstrong, David G
2018-01-01
The study aimed to evaluate the ratio of venous contamination in diabetic cases without foot lesion, with foot lesion and with Charcot neuroarthropathy (CN). Bolus-chase three-dimensional magnetic resonance (MR) of 396 extremities of patients with diabetes mellitus was analyzed, retrospectively. Extremities were divided into three groups as follows: diabetic patients without foot ulcer or Charcot arthropathy (Group A), patients with diabetic foot ulcers (Group B) and patients with CN accompanying diabetic foot ulcers (Group C). Furthermore, amount of venous contamination classified as no venous contamination, mild venous contamination, and severe venous contamination. The relationship between venous contamination and extremity groups was investigated. Severe venous contamination was seen in Group A, Group B, and Group C, 5.6%, 15.2%, and 34.1%, respectively. Statistically significant difference was seen between groups with regard to venous contamination. Venous contamination following bolus chase MR was higher in patients with CN.
Tapping but not massage enhances vasodilation and improves venous palpation of cutaneous veins.
Ichimura, Mika; Sasaki, Shinsuke; Mori, Masaharu; Ogino, Tetsuya
2015-01-01
This paper investigated whether tapping on the median cubital vein or massaging the forearm was more effective in obtaining better venous palpation for venipuncture. Forty healthy volunteers in their twenties were subjected to tapping (10 times in 5 sec) or massage (10 strokes in 20 sec from the wrist to the cubital fossa) under tourniquet inflation on the upper arm. Venous palpation was assessed using the venous palpation score (0-6, with 0 being impalpable). Three venous factors-venous depth, cross-sectional area, and elevation-were also measured using ultrasonography. The venous palpation score increased significantly by tapping but not by massage. Moreover, all 3 venous measurements changed significantly by tapping, while only the depth decreased significantly by massage. The three venous measurements correlated significantly with the venous palpation score, indicating that they are useful objective indicators for evaluating vasodilation. We suggest that tapping is an effective vasodilation technique.
Glueck, Charles J; Jetty, Vybhav; Goldenberg, Naila; Shah, Parth; Wang, Ping
2017-11-01
We compared thrombophilia and hypofibrinolysis in 6 men with Klinefelter syndrome (KS), without previously known familial thrombophilia, who had sustained deep venous thrombosis (DVT)-pulmonary emboli (PE) or mesenteric artery thrombosis on testosterone replacement therapy (TRT). After the diagnosis of KS, TRT had been started in the 6 men at ages 11, 12, 13, 13, 19, and 48 years. After starting TRT, DVT-PE or mesenteric artery thrombosis was developed in 6 months, 1, 11, 11, 12, and 49 years. Of the 6 men, 4 had high (>150%) factor VIII (177%, 192%, 263%, and 293%), 3 had high (>150%) factor XI (165%, 181%, and 193%), 1 was heterozygous for the factor V Leiden mutation, and 1 was heterozygous for the G20210A prothrombin gene mutation. None of the 6 men had a precipitating event before their DVT-PE. We speculate that the previously known increased rate of DVT-PE and other thrombi in KS reflects an interaction between prothrombotic, long-term TRT with previously undiagnosed familial thrombophilia. Thrombophilia screening in men with KS before starting TRT would identify a cohort at increased risk for subsequent DVT-PE, providing an optimally informed estimate of the risk/benefit ratio of TRT.
Effects of warm-up intensity on oxygen transport during supramaximal exercise in horses.
Mukai, Kazutaka; Hiraga, Atsushi; Eto, Daisuke; Takahashi, Toshiyuki; Hada, Tetsuro; Tsubone, Hirokazu; Jones, James H
2008-05-01
To determine whether warm-up exercise at different intensities alters kinetics and total contribution of aerobic power to total metabolic power in subsequent supramaximal exercise in horses. 11 horses. Horses ran at a sprint until fatigued at 115% of maximal oxygen consumption rate (VO(2max)), beginning at 10 minutes following each of 3 warm-up protocols: no warmup (NoWU), 1 minute at 70% VO(2max) (moderate-intensity warm-up [MoWU]), or 1 minute at 115% VO(2max) (high-intensity warm-up [HiWU]). Cardiopulmonary and blood gas variables were measured during exercise. The VO(2) was significantly higher in HiWU and MoWU than in NoWU throughout the sprint exercise period. Blood lactate accumulation rate in the first 60 seconds was significantly lower in MoWU and HiWU than in NoWU. Specific cardiac output after 60 seconds of sprint exercise was not significantly different among the 3 protocols; however, the arterial mixed-venous oxygen concentration difference was significantly higher in HiWU than in NoWU primarily because of decreased mixed-venous saturation and tension. Run time to fatigue following MoWU was significantly greater than that with NoWU, and there was no difference in time to fatigue between MoWU and HiWU. HiWU and MoWU increased peak values for VO(2) and decreased blood lactate accumulation rate during the first minute of intense exercise, suggesting a greater use of aerobic than net anaerobic power during this period.
Paarmann, Hauke; Heringlake, Matthias; Heinze, Hermann; Hanke, Thorsten; Sier, Holger; Karsten, Jan; Schön, Julika
2012-03-01
Transapical transcatheter aortic valve implantation (TA-TAVI) is increasingly used to treat aortic valve stenosis in high-risk patients. Mixed venous oxygen saturation (SvO(2)) is still the 'gold standard' for the determination of the systemic oxygen delivery to consumption ratio in cardiac surgery patients. Recent data suggest that regional cerebral oxygen saturation (rScO(2)) determined by near-infrared spectroscopy is closely related to SvO(2). The present study compares rScO(2) and SvO(2) in patients undergoing TA-TAVI. n = 20 cardiac surgery patients scheduled for TA-TAVI were enrolled in this prospective observational study. SvO(2) and rScO(2) were determined at predefined time points during the procedure. Correlation and Bland-Altman analysis of the complete data set showed a correlation coefficient of r(2 )= 0.7 between rScO(2) and SvO(2) (P < 0.0001), a mean difference (bias) of 5.8 with limits of agreement (1.96 SD) of -6.8 to 18.3% and a percentage error of 17.5%. At all predefined time points correlation was moderate (r(2 )= 0.50) to close (r = 0.84), and the percentage error was <24%. RScO(2) determined by near-infrared spectroscopy is correlated to SvO(2) during varying haemodynamic conditions in patients undergoing TA-TAVI. This suggests that rScO(2) is reflective not only of the cerebral, but also of the systemic oxygen balance.
Mechanical and Durability Properties of Fly Ash Based Concrete Exposed to Marine Environment
NASA Astrophysics Data System (ADS)
Kagadgar, Sarfaraz Ahmed; Saha, Suman; Rajasekaran, C.
2017-06-01
Efforts over the past few years for improving the performance of concrete suggest that cement replacement with mineral admixtures can enhance the strength and durability of concrete. Feasibility of producing good quality concrete by using alccofine and fly ash replacements is investigated and also the potential benefits from their incorporation were looked into. In this study, an attempt has been made to assess the performance of concrete in severe marine conditions exposed upto a period of 150 days. This work investigates the influence of alccofine and fly ash as partial replacement of cement in various percentages (Alccofine - 5% replacement to cement content) and (fly ash - 0%, 15%, 30%, 50% & 60% to total cementitious content) on mechanical and durability properties (Permit ion permeability test and corrosion current density) of concrete. Usage of alccofine and high quantity of fly ash as additional cementitious materials in concrete has resulted in higher workability of concrete. Inclusion of alccofine shows an early strength gaining property whereas fly ash results in gaining strength at later stage. Concrete mixes containing 5% alccofine with 15% fly ash replacement reported greater compressive strength than the other concrete mixes cured in both curing conditions. Durability test conducted at 56 and 150 days indicated that concrete containing higher percentages of fly ash resulted in lower permeability as well lesser corrosion density.
Instiaty, Insti; Lindegardh, Niklas; Jittmala, Podjanee; Hanpithakpong, Warunee; Blessborn, Daniel; Pukrittayakamee, Sasithon; White, Nicholas J.
2013-01-01
Oseltamivir and oseltamivir carboxylate concentrations were measured in venous plasma, venous blood, and capillary blood taken simultaneously from 24 healthy volunteers. Median (range) venous-blood-to-plasma ratios were 1.42 (0.920 to 1.97) for oseltamivir and 0.673 (0.564 to 0.814) for oseltamivir carboxylate. Capillary blood/venous plasma ratios were 1.32 (0.737 to 3.16) for oseltamivir and 0.685 (0.502 to 1.34) for oseltamivir carboxylate. Oseltamivir concentrations in venous and capillary blood were similar. Oseltamivir carboxylate showed a time-dependent distribution between venous and capillary blood. PMID:23507284
Rao, Allison J.; Erickson, Brandon J.; Cvetanovich, Gregory L.; Yanke, Adam B.; Bach, Bernard R.; Cole, Brian J.
2015-01-01
Meniscal tears are the most common knee injury, and partial meniscectomies are the most common orthopaedic surgical procedure. The injured meniscus has an impaired ability to distribute load and resist tibial translation. Partial or complete loss of the meniscus promotes early development of chondromalacia and osteoarthritis. The primary goal of treatment for meniscus-deficient knees is to provide symptomatic relief, ideally to delay advanced joint space narrowing, and ultimately, joint replacement. Surgical treatments, including meniscal allograft transplantation (MAT), high tibial osteotomy (HTO), and distal femoral osteotomy (DFO), are options that attempt to decrease the loads on the articular cartilage of the meniscus-deficient compartment by replacing meniscal tissue or altering joint alignment. Clinical and biomechanical studies have reported promising outcomes for MAT, HTO, and DFO in the postmeniscectomized knee. These procedures can be performed alone or in conjunction with ligament reconstruction or chondral procedures (reparative, restorative, or reconstructive) to optimize stability and longevity of the knee. Complications can include fracture, nonunion, patella baja, compartment syndrome, infection, and deep venous thrombosis. MAT, HTO, and DFO are effective options for young patients suffering from pain and functional limitations secondary to meniscal deficiency. PMID:26779547
Risk factors associated with PICC-related upper extremity venous thrombosis in cancer patients.
Yi, Xiao-lei; Chen, Jie; Li, Jia; Feng, Liang; Wang, Yan; Zhu, Jia-An; Shen, E; Hu, Bing
2014-03-01
To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality of patients' life. It is very important to grasp the indications to reduce the incidence rate of peripherally inserted central venous catheters-related upper extremity venous thrombosis. © 2013 John Wiley & Sons Ltd.
Słonecka, Iwona; Łukasik, Krzysztof; Fornalski, Krzysztof W
2018-06-04
The present paper proposes two methods of calculating components of the dose absorbed by the human body after exposure to a mixed neutron and gamma radiation field. The article presents a novel approach to replace the common iterative method in its analytical form, thus reducing the calculation time. It also shows a possibility of estimating the neutron and gamma doses when their ratio in a mixed beam is not precisely known.
Systemic venous drainage: can we help Newton?
Corno, Antonio F
2007-06-01
In recent years substantial progress occurred in the techniques of cardiopulmonary bypass, but the factor potentially limiting the flexibility of cardiopulmonary bypass remains the drainage of the systemic venous return. In the daily clinical practice of cardiac surgery, the amount of systemic venous return on cardiopulmonary bypass is directly correlated with the amount of the pump flow. As a consequence, the pump flow is limited by the amount of venous return that the pump is receiving. On cardiopulmonary bypass the amount of venous drainage depends upon the central venous pressure, the height differential between patient and inlet of the venous line into the venous reservoir, and the resistance in the venous cannula(s) and circuit. The factors determining the venous return to be taken into consideration in cardiac surgery are the following: (a) characteristics of the individual patient; (b) type of planned surgical procedure; (c) type of venous cannula(s); (d) type of circuit for cardiopulmonary bypass; (e) strategy of cardiopulmonary bypass; (f) use of accessory mechanical systems to increased the systemic venous return. The careful pre-operative evaluation of all the elements affecting the systemic venous drainage, including the characteristics of the individual patient and the type of required surgical procedure, the choice of the best strategy of cardiopulmonary bypass, and the use of the most advanced materials and tools, can provide a systemic venous drainage substantially better than what it would be allowed by the simple "Law of universal gravitation" by Isaac Newton.
Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.
Holly, Brian P; Steenburg, Scott D
2011-01-01
Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.
Wall, Peter Dh; Ahmed, Imran; Metcalfe, Andrew; Price, Andrew J; Seers, Kate; Hutchinson, Charles E; Parsons, Helen; Warwick, Jane; Rahman, Bushra; Brown, Jaclyn; Underwood, Martin
2018-04-10
This study is designed to determine whether a full randomised controlled trial (RCT) examining the clinical effectiveness and safety of total knee replacement surgery with or without a tourniquet is warranted and feasible. Single centre, patient-blinded and assessor-blinded RCT. A computer-generated randomisation service will allocate 50 participants into one of two trial treatments, surgery with or without a tourniquet. The primary objective is to estimate recruitment, crossovers and follow-up of patients. All patients will have an MRI scan of their brain preoperatively and day 1 or 2 postoperatively to identify ischaemic cerebral emboli (primary clinical outcome). Oxford Cognitive Screen, Montreal Cognitive Assessment and Mini-Mental State Examination will be evaluated as outcome tools for measuring cognitive impairment at days 1, 2 and 7 postoperatively. Thigh pain, blood transfusion requirements, venous thromboembolism, revision surgery, surgical complications, mortality and Oxford knee and five-level EuroQol-5D scores will be collected over 12 months. Integrated qualitative research study : 30 trial patients and 20 knee surgeons will take part in semistructured interviews. Interviews will capture views regarding the pilot trial and explore barriers and potential solutions to a full trial. Multicentre cohort study : UK National Joint Registry data will be linked to Hospital Episode Statistics to estimate the relationship between tourniquet use and venous thromboembolic event, length of hospital stay, risk of revision surgery and death. The study will conclude with a multidisciplinary workshop to reach a consensus on whether a full trial is warranted and feasible. National Research Ethics Committee (West Midlands-Edgbaston) approved this study on 27 January 2016 (15/WM/0455). The study is sponsored by University of Warwick and University Hospitals Coventry and Warwickshire. The results will be disseminated via high-impact peer-reviewed publication. ISRCTN20873088; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Daniel C. Donato; Joseph B. Fontaine; John L. Campbell; W. Douglas Robinson; J. Boone Kauffman; Beverly E. Law
2009-01-01
Large-scale wildfires (~104-106 ha) have the potential to eliminate seed sources over broad areas and thus may lead to qualitatively different regeneration dynamics than in small burns; however, regeneration after such events has received little study in temperate forests. Following a 200 000 ha mixed-severity...
DOT National Transportation Integrated Search
1992-06-01
The Aids to Navigation (ATON) Service Force Mix (SFM) 2000 Project is documented in a Project Overview and three separately bound volumes. This is Volume III. The Project Overview describes the purpose, approach, analysis, and results of the ATON SFM...
Effect of flour-oil composite as powdered fat source in low-fat cake mixes
USDA-ARS?s Scientific Manuscript database
Excess steam jet-cooked composites containing wheat flour and 30 to 55% canola oil were drum dried and used to replace the oil and part of the flour in low-fat cake mix formulations. Specific gravity and viscosity of cake batters were measured. The cakes were analyzed for crumb grain, color, textu...
NASA Astrophysics Data System (ADS)
Himabindu, Ch.; Geethasri, Ch.; Hari, N.
2018-05-01
Cement mortar is a mixture of cement and sand. Usage of high amount of cement increases the consumption of natural resources and electric power. To overcome this problem we need to replace cement with some other material. Cement is replaced with many other materials like ceramic powder, silica fume, fly ash, granulated blast furnace slag, metakaolin etc.. In this research cement is replaced with ceramic powder and silica fume. Different combinations of ceramic powder and silica fume in cement were replaced. Cement mortar cubes of 1:3 grade were prepared. These cubes were cured under normal water for 7 days, 14days and 28 days. Compressive strength test was conducted for all mixes of cement mortar cubes.
Mixing of thawed coagulation samples prior to testing: Is any technique better than another?
Lima-Oliveira, Gabriel; Adcock, Dorothy M; Salvagno, Gian Luca; Favaloro, Emmanuel J; Lippi, Giuseppe
2016-12-01
Thus study was aimed to investigate whether the mixing technique could influence the results of routine and specialized clotting tests on post-thawed specimens. The sample population consisted of 13 healthy volunteers. Venous blood was collected by evacuated system into three 3.5mL tubes containing 0.109mmol/L buffered sodium citrate. The three blood tubes of each subject were pooled immediately after collection inside a Falcon 15mL tube, then mixed by 6 gentle end-over-end inversions, and centrifuged at 1500g for 15min. Plasma-pool of each subject was then divided in 4 identical aliquots. All aliquots were thawed after 2-day freezing -70°C. Immediately afterwards, the plasma of the four paired aliquots were treated using four different techniques: (a) reference procedure, entailing 6 gentle end-over-end inversions; (b) placing the sample on a blood tube rocker (i.e., rotor mixing) for 5min to induce agitation and mixing; (c) use of a vortex mixer for 20s to induce agitation and mixing; and (d) no mixing. The significance of differences against the reference technique for mixing thawed plasma specimens (i.e., 6 gentle end-over-end inversions) were assessed with paired Student's t-test. The statistical significance was set at p<0.05. As compared to the reference 6-time gentle inversion technique, statistically significant differences were only observed for fibrinogen, and factor VIII in plasma mixed on tube rocker. Some trends were observed in the remaining other cases, but the bias did not achieve statistical significance. We hence suggest that each laboratory should standardize the procedures for mixing of thawed plasma according to a single technique. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in Humans
NASA Technical Reports Server (NTRS)
Watenpaugh, Donald E.
1996-01-01
Human venous compliance hypothetically decreases from upper to lower body as a mechanism for maintenance of the hydrostatic indifference level 'headward' in the body, near the heart. This maintains cardiac filling pressure, and thus cardiac output and cerebral perfusion, during orthostasis. This project entailed four steps. First, acute whole-body tilting was employed to alter human calf and neck venous volumes. Subjects were tilted on a tilt table equipped with a footplate as follows: 90 deg, 53 deg, 30 deg, 12 deg, O deg, -6 deg, -12 deg, -6 deg, O deg, 12 deg, 30 deg, 53 deg, and 90 deg. Tilt angles were held for 30 sec each, with 10 sec transitions between angles. Neck volume increased and calf volume decreased during head-down tilting, and the opposite occurred during head-up tilt. Second, I sought to cross-validate Katkov and Chestukhin's (1980) measurements of human leg and neck venous pressures during whole-body tilting, so that those data could be used with volume data from the present study to calculate calf and neck venous compliance (compliance = (Delta)volume/(Delta)pressure). Direct measurements of venous pressures during postural chances and whole-body tilting confirmed that the local changes in venous pressures seen by Katkov and Chestukhin (1980) are valid. The present data also confirmed that gravitational changes in calf venous pressure substantially exceed those changes in upper body venous pressure. Third, the volume and pressure data above were used to find that human neck venous compliance exceeds calf venous compliance by a factor of 6, thereby upholding the primary hypothesis. Also, calf and neck venous compliance correlated significantly with each other (r(exp 2) = 0.56). Fourth, I wished to determine whether human calf muscle activation during head-up tilt reduces calf venous compliance. Findings from tilting and from supine assessments of relaxed calf venous compliance were similar, indicating that tilt-induced muscle activation is relatively unimportant. Low calf venous compliance probably results from stiffer venous, skeletal muscle, and connective tissues, and better-developed local and central neural controls of venous distensibility. This research establishes that upper-to-lower body reduction of venous compliance can explain headward positioning of the hydrostatic indifference level in humans.
Chemical Kinetics Interpretation of Hypergolicity of Ionic Liquid-Based Systems
2009-04-01
acid (WFNA) mixtures 6 4. Thermochemistry of imidazoles, triazoles and tetrazoles 8 5. Thermochemistry of compounds formed...reactivity of gaseous mixtures formed above ionic liquids (ILs) when mixed with white fuming nitric acid (WFNA). After a general introduction on the...replacement for NTO is also of interest but probably less crucial. For instance, NTO could be replaced by nitric acid (or by any other suitable
The use of shale ash in dry mix construction materials
NASA Astrophysics Data System (ADS)
Gulbe, L.; Setina, J.; Juhnevica, I.
2017-10-01
The research was made to determine the use of shale ash usage in dry mix construction materials by replacing part of cement amount. Cement mortar ZM produced by SIA Sakret and two types of shale ashes from Narva Power plant (cyclone ash and electrostatic precipitator ash) were used. Fresh mortar properties, hardened mortar bulk density, thermal conductivity (λ10, dry) (table value) were tested in mortar ZM samples and mortar samples in which 20% of the amount of cement was replaced by ash. Compressive strenght, frost resistance and resistance to sulphate salt solutions were checked. It was stated that the use of electrostatic precipitator ash had a little change of the material properties, but the cyclone ash significantly reduced the mechanical strength of the material.
Mohammadabadi, Tahereh; Jolazadeh, Alireza
2017-08-01
This study investigated the effect of replacing alfalfa hay by subabul leaf meal (SLM) on digestion, fermentation parameters and rumen bacteria and fungi activity of Najdi goats. Six Najdi goats (150 ± 15 days of age and initial body weight of 35 ± 1.1 kg) were randomly assigned to one of two dietary treatments in a balanced completely randomized design (three goats per treatment) for 56 days. Experimental treatments included alfalfa hay as control group and diet containing SLM (SLM replacing alfalfa hay at 50% level). Bacterial and fungi activity and rumen fermentation parameters of animals fed experimental diets were determined. Dry matter disappearance (DMD) was unaffected by replacing SLM with alfalfa hay for both rumen bacteria and fungi in different incubation times, except for 48 h of incubation in specific culture medium of mixed rumen bacteria, which decreased for SLM group (P > 0.05). NDF disappearance (NDFD) and ADF disappearance (ADFD) after 24 and 48 h of incubation in specific culture medium of mixed rumen bacteria was not affected by experimental diets (P > 0.05). However, 72 h after incubation, NDFD in SLM treatment decreased (P > 0.05). Gas production parameters of rumen bacteria were similar for both experimental diets, but partitioning factor (PF), efficiency microbial biomass production (EMBP), microbial protein production (MP), and organic matter truly digested (OMTD) decreased (p < 0.05) in specific culture medium of mixed rumen fungi for SLM diet. There was significant decrease in total protozoa population for diet containing SLM (p < 0.05). Results indicated that replacement of alfalfa hay by SLM had no major effect on rumen microorganisms' activity of Najdi goats, so it may be used as an alternative for alfalfa (at 50% level) in susceptible areas.
NASA Technical Reports Server (NTRS)
Westby, Christian M.; Lee, Stuart M. C.; Stenger, Michael B.; Platts, Steven H.
2012-01-01
Space flight-induced orthostatic intolerance (OI) is more prevalent in female (F) than male (M) astronauts. The mechanisms explaining the higher incidence of OI in F are unclear. We tested the hypothesis that venous compliance would be higher in F more than M following 6 deg head-down bed rest (BR) and would be associated with constrictor dysfunction. Using 2-D ultrasound, dorsal hand (DHV) and dorsal foot (DFV) vein compliances were determined in 24 subjects (10 F, 14 M; 35 +/- 1 yr) by measuring mean diameter response to increasing congestion pressure (0, 20, 30, and 40 mmHg) before and after 60 d of BR. Constrictor function was assessed by intravenous infusions of Ketorolac (KE; 1.5 ig/min) Phenylephrine (PE; 3160 ng/min), and L-NMMA (50 ig/min). The effects of BR between F vs. M and hand vs. foot were determined using mixed-effects linear regression. DFV but not DHV compliance changed in response to BR (p=0.012). Mean DFV increased significantly (0.903 mm to 1.191mm) in F but decreased in M (1.353 mm to 1.154 mm). DFV constrictor response was not different between sexes in response to BR (KE; p=0.647, PE; p=0.717, and L-NMMA; p=0.825). These BR data suggest that the higher incidence of OI in F astronauts may be related to increased lower limb venous compliance, contributing to blood pooling upon standing. Notably, changes to DFV compliance was not accompanied by impaired constrictor function.
Macartney, F J; Zuberbuhler, J R; Anderson, R H
1980-01-01
The atrial morphology and venous connections were assessed "blind" in 51 necropsy specimens from patients with visceral heterotaxy. This was compared with bronchial morphology as established by dissection. Six specimens were found to have both atria and bronchi in situs solitus or inversus, and were rejected. In the remainder, atrial isomerism was diagnosed, though this required minor revision of the atrial assessment in two patients. Thirty-four patients had isomeric right atria and bronchi, while 11 had isomeric left atria and bronchi. In seven cases, splenic status was unknown, but in seven of the remaining 38 (18.4%) atrial isomerism was not associated with either asplenia or polysplenia. Nevertheless, right isomerism was strongly associated with total anomalous pulmonary venous drainage (as is asplenia) and left isomerism was likewise associated with interruption of the inferior vena cava (as is polysplenia). Bilateral superior venae cavae and hepatic veins, and absence of the coronary sinus, were frequent in both forms of isomerism (as they are in asplenia and polysplenia). These findings suggest that atrial situs can be defined as solitus inversus, right isomerism, and left isomerism. This determination of atrial situs is quite independent of any other abnormalities of visceral situs. The high incidence of anomalies of both venous return and common atrium resulted in presumed complete mixing of blood at atrial level in all but one patient (97.8%), making the haemodynamic connection between atria and ventricles almost always ambiguous. To describe this anatomical connection as ambiguous when there are two ventricles present is therefore no more than recognition of anatomical and haemodynamic reality. Images PMID:7459148
21 CFR 870.1140 - Venous blood pressure manometer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...
21 CFR 870.1140 - Venous blood pressure manometer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...
21 CFR 870.1140 - Venous blood pressure manometer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...
21 CFR 870.1140 - Venous blood pressure manometer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...
Current Status of the Application of Intracranial Venous Sinus Stenting
Xu, Kan; Yu, Tiecheng; Yuan, Yongjie; Yu, Jinlu
2015-01-01
The intracranial venous sinus is an important component of vascular disease. Many diseases involve the venous sinus and are accompanied by venous sinus stenosis (VSS), which leads to increased venous pressure and high intracranial pressure. Recent research has focused on stenting as a treatment for VSS related to these diseases. However, a systematic understanding of venous sinus stenting (VS-Stenting) is lacking. Herein, the literature on idiopathic intracranial hypertension (IIH), venous pulsatile tinnitus, sinus thrombosis, high draining venous pressure in dural arteriovenous fistula (AVF) and arteriovenous malformation (AVM), and tumor-caused VSS was reviewed and analyzed to summarize experiences with VS-Stenting as a treatment. The literature review showed that satisfactory therapeutic effects can be achieved through stent angioplasty. Thus, the present study suggests that selective stent release in the venous sinus can effectively treat these diseases and provide new possibilities for treating intracranial vascular disease. PMID:26516306
Christianto, S; Lau, A; Li, K Y; Yang, W F; Su, Y X
2018-05-01
Venous compromise is still the most common cause of free flap failure. The use of two venous anastomoses has been advocated to reduce venous compromise. However, the effectiveness of this approach remains controversial. A systematic review and cumulative meta-analysis was performed to assess the effect of one versus two venous anastomoses on venous compromise and free flap failure in head and neck microsurgical reconstruction. A total of 27 articles reporting 7389 flaps were included in this study. On comparison of one versus two venous anastomoses, the odds ratio (OR) for flap failure was 1.66 (95% confidence interval 1.11-2.50; P=0.014) and for venous compromise was 1.50 (95% confidence interval 1.10-2.05; P=0.011), suggesting a significant increase in the flap failure rate and venous compromise rate in the single venous anastomosis group. These results show that the execution of two venous anastomoses has significant effects on reducing the vascular compromise and free flap failure rate in head and neck reconstruction. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Kotoda, Atsushi; Akimoto, Tetsu; Sugase, Taro; Yamamoto, Hisashi; Kusano, Eiji
2013-01-01
Central venous stenosis (CVS) is a serious complication for chronic hemodialysis (HD) patients. Previous reports of CVS have focused on prior central venous catheterization, because of the higher prevalence and potential for prevention of such an event. However, recent studies have demonstrated that CVS may also develop without a history of central venous catheterization. Although information about the etiological backgrounds regarding the development of CVS without previous central venous catheterization have gradually accumulated, the clinical impact of the chronic compression of the central venous system by the surrounding structures, which may likely determine the central venous susceptibility to CVS, remains poorly understood. This study proposes the hypothesis that the combination of chronic venous compression at the level of thoracic outlet characterized by the natural physique and elevated venous flow induced by the creation of vascular access should be evaluated as a potential factor for the development of CVS, since they may accelerate the development of venous stenosis, presumably through the stimulation of intimal hyperplasia, and thereby the subclavian venous susceptibility to CVS should be determined. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jagalur Mahalingasharma, Srishaila; Prakash, Parasivamurthy; Vishwanath, K. N.; Jawali, Veena
2017-06-01
This paper presents experimental investigations made on the influence of chemical, physical, morphological and mineralogical properties of mineral admixtures such as fly ash, ground granulate blast furnace slag, metakaoline and micro silica used as a replacement of cement in self compacting concrete on workability and compressive strength. Nineteen concrete mixes were cast by replacing with cement by fly ash or ground granulated blast furnace slag as binary blend at 30%, 40%, 50% and with addition of micro silica and metakaoline at 10% as a ternary blend with fly ash, ground granulated blast furnace slag and obtained results were compare with control mix. Water powder ratio 0.3 and super plasticizer dosage 1% of cementitious material was kept constant for all the mixes. The self compacting concrete tested for slump flow, V-funnel, L-Box, J-Ring, T50, and compressive strength on concrete cube were determined at age of 3, 7, 28, 56, 90 days.
The effect of operating conditions on the performance of soil slurry-SBRs.
Cassidy, D P; Irvine, R L
2001-01-01
Biological treatment of a silty clay loam with aged diesel fuel contamination was conducted in 8 L Soil Slurry-Sequencing Batch Reactors (SS-SBRs). The purpose was to monitor slurry conditions and evaluate reactor performance for varying solids concentration (5%, 25%, 40%, 50%), mixing speed (300 rpm, 700 rpm, 1200 rpm), retention time (8 d, 10 d, 20 d), and volume replaced per cycle (10%, 50%, 90%). Diesel fuel was measured in slurry and in filtered aqueous samples. Oxygen uptake rate (OUR) was monitored. Aggregate size was measured with sieve analyses. Biosurfactant production was quantified with surface tension measurements. Increasing solids concentration and decreasing mixing speed resulted in increased aggregate size, which in turn increased effluent diesel fuel concentrations. Diesel fuel removal was unaffected by retention time and volume replaced per cycle. Biosurfactant production occurred with all operating strategies. Foam thickness was related to surfactant concentration and mixing speed. OUR, surfactant concentration, and foam thickness increased with increasing diesel fuel added per cycle.
... ulcers; Ulcers - venous; Venous ulcer; Venous insufficiency - stasis dermatitis; Vein - stasis dermatitis ... veins. Some people with venous insufficiency develop stasis dermatitis. Blood pools in the veins of the lower ...
A New Technique for Femoral Venous Access in Infants Using Arterial Injection Venous Return Guidance
Ebishima, Hironori; Kitano, Masataka; Kurosaki, Kenichi; Shiraishi, Isao
2017-01-01
Objectives: Although venography guidance is helpful for central venous catheter placement, it is sometimes difficult to place a peripheral intravenous cannula for enhancement. We designed a new technique for establishing femoral venous access using venography guidance in the return phase of peripheral arteriography. This new technique was named arterial injection venous return guidance. Here we assessed the efficacy and safety of arterial injection venous return guidance. Methods: We reviewed data of 29 infants less than 6 months old undergoing catheter intervention at our institute in 2014. Of the 29 patients, femoral venous cannulation was performed using arterial injection venous return guidance in 5 patients, venography in 20 patients, and the landmark method in 4 patients. The technical success rates and incidence of complications were compared. Results: The overall success rates were 100% in the arterial injection venous return-guided and venography-guided groups. The mean procedure duration and mean contrast material injection time were similar between the groups. The contrast effect on the femoral vein in the arterial injection venous return-guided group was lower than that in the venography-guided group, but adequate for surgery. The overall complication rate was 17%, and obstruction of previously placed intravenous catheters was the most common complication. Conclusions: Therefore, the arterial injection venous return guidance technique was as safe and efficient as venography for establishing venous access. PMID:29034015
Jones, Roy Wesley; Parkerson, Godfrey Ross; Ottinger, Mary; Rodriguez, Eduardo; Park, Brian
2017-01-01
We present a case of recurrent bilateral lower extremity venous stasis ulcers in association with a superficial venous aneurysm at the right saphenofemoral junction that was misdiagnosed on preoperative duplex scanning. A 53-year-old female presented to our clinic with 6-year history of bilateral lower extremity venous stasis ulcers. Her past medical history was significant for refractory venous stasis ulcers of the bilateral lower extremities present for 6 years and morbid obesity. Preoperative venous duplex demonstrated severe venous insufficiency of the superficial and deep systems, but a venous aneurysm was not appreciated. During the high ligation of the right saphenofemoral junction, a 3 × 4 × 5 cm aneurysm was encountered. Repair consisted of aneurysm resection, high ligation of the greater saphenous vein, dissociation of the great saphenous and anterior saphenous veins, and stab phlebectomy of large varicose veins of the thigh and lower leg. The patient recovered uneventfully and experienced complete healing of the venous stasis ulcer in several weeks. Superficial venous aneurysms of the lower extremity are rare and can be often missed on preoperative duplex ultrasound imaging. Large diameter measurements of the proximal greater saphenous vein and obesity increase the risk of misdiagnosing venous aneurysms with duplex imaging; therefore, clinical suspicion must remain high. These aneurysms can be associated with significant symptoms for which repair is indicated.
Cerebral venous circulatory system evaluation by ultrasonography.
Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost
2013-06-01
Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-09
... subparagraph (4)(b)4, relating to sulfur dioxide, to correct an error in the standard condition for temperature... subparagraph (b)5(i) to clarify the specific equipment covered by permit-by-rule for hot mix asphalt plants... million BtU per hour'' is replaced by ``hot mix asphalt facilities,'' to best describe the facilities...
Equilibrium of adsorption of mixed milk protein/surfactant solutions at the water/air interface.
Kotsmar, C; Grigoriev, D O; Xu, F; Aksenenko, E V; Fainerman, V B; Leser, M E; Miller, R
2008-12-16
Ellipsometry and surface profile analysis tensiometry were used to study and compare the adsorption behavior of beta-lactoglobulin (BLG)/C10DMPO, beta-casein (BCS)/C10DMPO and BCS/C12DMPO mixtures at the air/solution interface. The adsorption from protein/surfactant mixed solutions is of competitive nature. The obtained adsorption isotherms suggest a gradual replacement of the protein molecules at the interface with increasing surfactant concentration for all studied mixed systems. The thickness, refractive index, and the adsorbed amount of the respective adsorption layers, determined by ellipsometry, decrease monotonically and reach values close to those for a surface covered only by surfactant molecules, indicating the absence of proteins from a certain surfactant concentration on. These results correlate with the surface tension data. A continuous increase of adsorption layer thickness was observed up to this concentration, caused by the desorption of segments of the protein and transforming the thin surface layer into a rather diffuse and thick one. Replacement and structural changes of the protein molecules are discussed in terms of protein structure and surface activity of surfactant molecules. Theoretical models derived recently were used for the quantitative description of the equilibrium state of the mixed surface layers.
Experimental Study on Rise Husk Ash & Fly Ash Based Geo-Polymer Concrete Using M-Sand
NASA Astrophysics Data System (ADS)
Nanda Kishore, G.; Gayathri, B.
2017-08-01
Serious environmental problems by means of increasing the production of Ordinary Portland cement (OPC), which is conventionally used as the primary binder to produce cement concrete. An attempt has been made to reduce the use of ordinary Portland cement in cement concrete. There is no standard mix design of geo-polymer concrete, an effort has been made to know the physical, chemical properties and optimum mix of geo-polymer concrete mix design. Concrete cubes of 100 x 100 x 100 mm were prepared and cured under steam curing for about 24 hours at temperature range of 40°C to 60°C. Fly ash is replaced partially with rice husk ash at percentage of 10%, 15% and 25%. Sodium hydroxide and sodium silicate are of used as alkaline activators with 5 Molar and 10 Molar NaOH solutions. Natural sand is replaced with manufacture sand. Test results were compared with controlled concrete mix of grade M30. The results shows that as the percentage of rice husk ash and water content increases, compressive strength will be decreases and as molarity of the alkaline solution increases, strength will be increases.
Normal venous anatomy and physiology of the lower extremity.
Notowitz, L B
1993-06-01
Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.
Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.
Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D
2017-08-01
Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.
1980-05-01
abnormalities in pressure tracings of the systemic, the central venous or pulmonary arterial circulation. At some sites (especially the Latter-Day Saints...accurate measurement of central venous pressure has been by direct venous cannulation. However, a group of Swiss doctors has extended the principle of... venous stop flow pressure to develop a noninvasive method of measuring central venous pressure. The method consists of venous auscultation at the thoracic
Hepatic venous connection to a persistent inferior caval vein in left isomerism.
Guenthard, J; Carvalho, J S; Anderson, R H; Rigby, M L
1990-09-01
In 22 cases of left atrial isomerism studied at the Brompton Hospital, four cases were found to have an unusual arrangement of the abdominal vessels. There was persistence of an inferior caval vein, partially anomalous hepatic venous connection and additional continuation of part of the venous return from the lower body through the azygos venous system. This venous pattern had surgical implications in our index case, since redirection of the inferior caval venous return was necessary.
Strength and durability studies on concrete with partial replacement over burnt brick bat waste
NASA Astrophysics Data System (ADS)
Kanchidurai, S.; Bharani, G.; Saravana Raja Mohan, K.
2017-07-01
This paper presents the partial and complete replacement of over burnt brick bat (OBB) 20-30mm as coarse aggregate in the concrete. OBB are formed at extreme heating to a temperature not less than 1600 degree Celsius. The burnt bricks change from red to blue-black ceramics color. The series of tests are conducted to study the effect of 0%, 25%, 50%, 75% and 100% replacement of coarse aggregate with over burnt bricks. Totally 36numbers of 150mm concrete cube with 5 different percentage replacement mix are cast and tested and three numbers of the flexural beam. In durability aspects, water absorption and sorptivity were tested. Experimental results found 25-50% of overburnt brick bat wastes can be replaced with the normal and mass concrete without quality compromisation.
Development and freeze-thaw durability of high flyash-content concrete
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sajadi, J.
1987-01-01
Objectives were to investigate the effects on concrete strength, drying shrinkage, freeze-thaw durability, and air-void system parameters of replacing various amounts of portland cement with different types of fly ash and to compare selected characteristics of such fly-ash concretes and fly-ash concretes containing a high-range water-reducing admixture to those of a control mixture. It was concluded that concrete mixtures with 90-day compressive strengths equal to the control could be produced when large amounts of cement were replaced by fly ash. In addition, when the high-range water-reducing admixtures was employed, very large amounts of cement could be replaced by fly ashmore » to yield mixtures whose compressive strengths were equal to or greater than the strengths of the control mix at all ages. The maximum amount of cement that could be replaced for equal-strength mixtures depended upon the nature of the fly ash. Drying shrinkage of plain fly-ash concretes and fly-ash concretes containing the high-range water-reducing admixture were similar to those of the control mix. The optimum fly-ash content in a concrete is comparable in strength and durability to a conventional (control) concrete was influenced by the chemical and physical characteristics of the fly ash.« less
Engineering properties of concrete with partial utilization of used foundry sand.
Manoharan, Thiruvenkitam; Laksmanan, Dhamothiran; Mylsamy, Kaliyannan; Sivakumar, Pandian; Sircar, Anirbid
2018-01-01
Solid wastes generated from manufacturing industries are increasing at an alarming rate and it is consistently increasing. One such industrial solid waste is Used Foundry Sand (UFS). On the other hand, fine aggregates involved in the concrete are generally river sand, which is scarce, high cost and excavation of the river sand that promote environmental degradation. So, there is an urge to find some alternative solution to dispose UFS and to limit the use of river sand. In this research work, river sand was partially replaced by UFS. The percentage replacements were 0, 5, 10, 15, 20 and 25 wt% respectively. Experimental investigations were carried out to evaluate the mechanical, durability and micro-structural properties of M20 concrete at the age of 7, 28 and 91 day. XRD (X-ray Diffraction), EDX (Energy Dispersive X-ray) and optical-microscopic imaging analysis were performed to identify the presence of various compounds and micro cracks in the concrete with UFS. Comparative studies on control mix against trial mix were carried out. It was found that compression strength, flexural strength and modulus of elasticity were approximately constant up to 20 wt% UFS and decreased with further addition. Whereas, split tensile strength was increased after 20 wt% addition but it affects the other properties of concrete. The durability test results showed that the resistance of concrete against abrasion and rapid chloride permeability of the concrete mixture containing UFS up to 20 wt% were almost similar to the values of control mix. The findings suggest that UFS can effectively replace river sand. However, it is recommended that the replacement should not exceed 20 wt%. Copyright © 2017. Published by Elsevier Ltd.
Pofale, Arun D; Nadeem, Mohammed
2012-01-01
This investigation explores the possibility of utilizing granular slag as an alternative to fine aggregate (natural sand) in construction applications like masonry and plastering. Construction industry utilizes large volume of fine aggregate in all the applications which has resulted into shortage of good quality naturally available fine aggregate. Use of granular slag serves two fold purposes, i.e. waste utilisation as well as alternative eco-friendly green building material for construction. The investigation highlights comparative study of properties with partial and full replacement of fine aggregate (natural sand) by granular slag in cement mortar applications (masonry and plastering). For this purpose, cement mortar mix proportions from 1:3, 1:4, 1:5 & 1:6 by volume were selected for 0, 25, 50, 75 & 100% replacement levels with w/c ratios of 0.60, 0.65, 0.70 & 0.72 respectively. Based on the study results, it could be inferred that replacement of natural sand with granular slag from 25 to 75% increased the packing density of mortar which resulted into reduced w/c ratio, increased strength properties of all mortar mixes. Hence, it could be recommended that the granular slag could be effectively utilized as fine aggregate in masonry and plastering applications in place of conventional cement mortar mixes using natural sand.
A survey of current practice of vascular surgeons in venous disease management.
Bush, Ruth L; Gloviczki, Peter
2013-01-01
Acute venous thromboembolism and chronic venous diseases are common conditions that affect a large proportion of the United States population. The diagnosis of venous disease has improved, and the treatment options have rapidly evolved over the past decade. To date, it is unclear to what extent vascular surgeons have become involved in the modern management of venous disorders. This survey was undertaken to explore the current interest and practice of vascular surgeons in the contemporary care of venous disease. A survey was administered via a web-based platform to active and candidate members of the Society for Vascular Surgery (SVS). The survey included 30 questions investigating the characteristics of venous surgeons and scope of venous practice. Open-ended questions were also included for commentary. A total of 1879 surveys were sent to SVS members nationwide, and 385 members participated (response rate of 20.5%). The participants were mostly men (89.6%) with 37.7% practicing in an academic setting and 59.2% in private practice. The respondents treated superficial veins (92.9%) and deep veins (85.8%) in clinical practice, with 89.9% having their own vascular laboratory. A wide spectrum of interventions for superficial (91.9%), deep (85.8%), and perforator veins (52.7% endovenous, 19.4% subfascial endoscopic perforator surgery) are being performed by respondents. Only 26.2% had learned endovenous thermal ablation in their training program; however, over 96% of those performing venous interventions utilized this technique. Overall, the majority (85.5%) devoted 50% or less of practice to venous disorders. Respondents indicated that limitations to expansion of vein practices mainly involved challenges with third party payers, local competition, and existing large volumes of arterial interventions needing to be performed. Despite the widespread incorporation of venous disease into current vascular practices, 66.1% are not members of the American Venous Forum (AVF) or other venous society. Many believe there is still a lack of standardization of care and guidelines for venous disease. The care of patients with venous disease has become more widespread among SVS members, with most offering both deep and superficial venous interventions as well as incorporation of minimally invasive techniques into their treatment armamentarium. Dissemination and incorporation of protocols and guidelines into clinical practice as well as postgraduate courses in venous disease may be areas in which the SVS could facilitate members' involvement in the care of patients with venous disease. Published by Elsevier Inc.
Mozina, Hugo; Podbregar, Matej
2010-01-01
Discrepancies of 5-24% between superior vena cava oxygen saturation (ScvO2) and mixed venous oxygen saturation (SvO2) have been reported in patients with severe heart failure. Thenar muscle tissue oxygenation (StO2) measured with near-infrared spectroscopy (NIRS) during arterial occlusion testing decreases slower in sepsis/septic shock patients (lower StO2 deoxygenation rate). The StO2 deoxygenation rate is influenced by dobutamine. The aim of this study was to determine the relationship between the StO2 deoxygenation rate and the ScvO2-SvO2 discrepancy in patients with severe left heart failure and additional sepsis/septic shock treated with or without dobutamine. Fifty-two patients with severe left heart failure due to primary heart disease with additional severe sepsis/septic shock were included. SvO2 and ScvO2 were compared to the thenar muscle StO2 before and during arterial occlusion. SvO2 correlated significantly with ScvO2 (Pearson correlation 0.659, P = 0.001), however, Bland Altman analysis showed a clinically important difference between both variables (ScvO2-SvO2 mean 72 +/- 8%, ScvO2-SvO2 difference 9.4 +/- 7.5%). The ScvO2-SvO2 difference correlated with plasma lactate (Pearson correlation 0.400, P = 0.003) and the StO2 deoxygenation rate (Pearson correlation 0.651, P = 0.001). In the group of patients treated with dobutamine, the ScvO2-SvO2 difference correlated with plasma lactate (Pearson correlation 0.389, P = 0.011) and the StO2 deoxygenation rate (Pearson correlation 0.777, P = 0.0001). In patients with severe heart failure with additional severe sepsis/septic shock the ScvO2-SvO2 discrepancy presents a clinical problem. In these patients the skeletal muscle StO2 deoxygenation rate is inversely proportional to the difference between ScvO2 and SvO2; dobutamine does not influence this relationship. When using ScvO2 as a treatment goal, the NIRS measurement may prove to be a useful non-invasive diagnostic test to uncover patients with a normal ScvO2 but potentially an abnormally low SvO2. NCT00384644 ClinicalTrials.Gov.
[Surgical treatment of partial anomalous pulmonary venous drainage].
Cabrera, A; Idígoras, G; Sarrionandía, M J; Martínez, P; Rumoroso, J R; Alcíbar, J
1996-02-01
We studied all patients operated for partial anomalous pulmonary venous drainage and half-time follow-up. Twenty-eight patients with a mean age of 5 +/- 5 years (5 patients were less than 1 year old). There were sixteen male and twelve female patients. Thirteen patients were symptomatic (47%). The drainage was to the superior vena cava in thirteen cases, to the inferior vena cava in eight cases, to the right atrium in five cases, mixed (to the superior vena cava and to the inferior vena cava) in one case and to the innominate vein in one patient. The diagnosis was made through echocardiography and catheterization in 25 patients, whereas nuclear magnetic resonance was performed in the last five patients. All cases were corrected through medium thoracotomy, except for the single case in which the drainage was to the innominate vein). In 27 patients, the pulmonary veins were guided to the left atrium through an enlarged present atrial septal defect or through a created atrial septal defect. In one case a direct connection was performed from the veins to the left atrium. After the surgical correction, all patients underwent a color-coded Doppler echocardiography study and a nuclear magnetic resonance study was performed in five patients. Twenty-seven patients survived after surgical correction. The patient with a mixed drainage developed an obstruction of the superior vena cava, the pressure gradient was 9 mmHg. He required a second surgical procedure followed with angioplasty on two occasions during a six month period. Two patients showed an ectopic atrial rhythm at some late time. The patient who died was one month old and had an associated pulmonary parenchymal sequestration. Partial anomalous venous connection is a congenital heart disease which has an easy surgical correction. Complications may arise after the surgical correction, among them obstruction of the superior vena cava and arrythmias are most frequently found. Obstruction is present when 50% of the caval area is occupied by the patch. The arrythmias occur following all surgical techniques. In order to decrease the arrythmias it is necessary to perform a good hemosthasis at the site of the patch, to leave the sinus node free of compression and to perform the atrial incision at the posterior wall. The diagnosis and the follow-up can be performed with non-invasive procedures.
Three-dimensional venous anatomy of the dermis observed using stereography
Imanishi, Nobuaki; Kishi, Kazuo; Chang, Hak; Nakajima, Hideo; Aiso, Sadakazu
2008-01-01
Veins of the dermis have been investigated mainly by histological methods in the fields of anatomy and histology, and a large number of schemata of the veins have been depicted in a variety of textbooks. However, the schemata are usually two-dimensional and it is therefore difficult to envisage the actual vasculature of the dermal veins. In this study, we performed a stereographic study of the skin of three fresh cadavers that had been injected with radio-opaque dye, which was dispersed throughout the entire body. A venous network consisting of venous polygons of various sizes existed just under the dermis or in the deep zone of the dermis, which is generally called the subdermal venous plexus. There were many small vessels towards the inside of each venous polygon, and most of them ascended, branching off stereoscopically. Those branches anastomosed with each other, and they formed the dermal and subpapillary venous plexuses. However, there was little vascular connection between dermal venous plexuses of different venous polygons. The characteristic structure of the dermal venous plexus has been considered to bring about venous congestion of the skin in various clinical situations. PMID:18422525
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, I.; Royal, H.D.; Uren, R.F.
1984-01-01
Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. A range of normal values was defined in 19 subjects for per cent change in venous capacitance and venous outflow. Twenty-one patients with suspected deep venous thrombosis were studied prospectively using RPG, radionuclide venography (RV), and contrast venography (CV) to establish the usefulness of RPGmore » alone and in combination with RV in the diagnosis of deep venous thrombosis. RPG proved to be a reliable technique for the diagnosis of ileofemoral venous thrombosis (sensitivity, 91%; specificity, 100%). RV was less sensitive (73%) and less specific (93%) in diagnosing that condition. When RPG is used as the criterion for the detection of ileofemoral vein thrombosis and RV is used as the criterion for the detection of calf vein thrombosis, the combined techniques show improved sensitivity (92%) and specificity (93%) for the detection of all deep venous thromboses.« less
Fukuoka, Masato; Sugimoto, Takaki; Okita, Yutaka
2003-10-01
The purpose of this study was to evaluate lower extremity venous function in patients with chronic venous insufficiency, with foot venous pressure (FVP) measurements and air plethysmography (APG). Eighty-five limbs of 63 patients with a history of chronic venous insufficiency (CVI) from 1995 to 1999 were studied. FVP parameters studied included ambulatory venous pressure (AVP), percent decrease in FVP with manual calf compression (%drop), ratio of increase in FVP over 4 seconds after release of compression (4SR%), and time to 90% recovery of FVP were measured. APG parameters studied included functional venous volume, 90% refilling time (VFT90), venous filling index, ejection fraction, and residual volume fraction. Venous filling index and 90% refilling time were significantly decreased in limbs with stasis syndrome compared with the control group. AVP, %drop, and 4SR% also showed significantly decrease in limbs with stasis syndrome compared with those without it. AVP, %drop, and 4SR% were significantly different for the primary group compared with the secondary group, whereas no differences were found with regard to any APG parameter. APG enables prediction of the presence of CVI, whereas FVP measurements are more useful for evaluation of clinical severity of CVI.
Medical management of venous ulcers.
Pascarella, Luigi; Shortell, Cynthia K
2015-03-01
Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.
Alonso-Quintela, Paula; Oulego-Erroz, Ignacio; Rodriguez-Blanco, Silvia; Muñiz-Fontan, Manoel; Lapeña-López-de Armentia, Santiago; Rodriguez-Nuñez, Antonio
2015-11-01
To compare the use of bedside ultrasound and chest radiography to verify central venous catheter tip positioning. Prospective observational study. PICU of a university hospital. Patients aged 0-14 who required a central venous catheter. None. Central venous catheter tip location was confirmed by ultrasound and chest radiography. Central venous catheters were classified as intra-atrial or extra-atrial according to their positions in relation to the cavoatrial junction. Central venous catheters located outside the vena cava were considered malpositioned. The distance between the catheter tip and the cavoatrial junction was measured. The time elapsed from image capture to interpretation was recorded. Fifty-one central venous catheters in 40 patients were analyzed. Chest radiography and ultrasound results agreed 94% of the time (κ coefficient, 0.638; p < 0.001) in determining intra-atrial and extra-atrial locations and 92% of the time in determining the diagnosis of central venous catheter malposition (κ coefficient, 0.670; p < 0.001). Chest radiography indicated a greater distance between the central venous catheter tip and the cavoatrial junction than measured by ultrasound, with a mean difference of 0.38 cm (95% CI, +0.27, +0.48 cm). Three central venous catheters were classified as extra-atrial by chest radiography but as intra-atrial by ultrasound. To locate the central venous catheter tip, ultrasound required less time than chest radiography (22.96 min [20.43 min] vs 2.23 min [1.06 min]; p < 0.001). Bedside ultrasound showed a good agreement with chest radiography in detecting central venous catheter tip location and revealing incorrect positions. Ultrasound could be a preferable method for routine verification of central venous catheter tip and can contribute to increased patient safety.
Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan
2012-05-01
To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.
Jensen, Corey T; Chahin, Antoun; Amin, Veral D; Khalaf, Ahmed M; Elsayes, Khaled M; Wagner-Bartak, Nicolaus; Zhao, Bo; Zhou, Shouhao; Bedi, Deepak G
2017-09-01
To determine whether the qualitative sonographic appearance of slow deep venous flow in the lower extremities correlates with quantitative slow flow and an increased risk of deep venous thrombosis (DVT) in oncology patients. In this Institutional Review Board-approved retrospective study, we reviewed lower extremity venous Doppler sonographic examinations of 975 consecutive patients: 482 with slow flow and 493 with normal flow. The subjective slow venous flow and absence of initial DVT were confirmed by 2 radiologists. Peak velocities were recorded at 3 levels. Each patient was followed for DVT development. The associations between DVT and the presence of slow venous flow were examined by the Fisher exact test; a 2-sample t test was used for peak velocity and DVT group comparisons. The optimal cutoff peak velocity for correlation with the radiologists' perceived slow flow was determined by the Youden index. Deep venous thrombosis development in the slow-flow group (21 of 482 [4.36%]) was almost doubled compared with patients who had normal flow (11 of 493 [2.23%]; P = .0456). Measured peak venous velocities were lower in the slow-venous flow group (P < .001). Patients with subsequent DVT did not have a significant difference in venous velocities compared with their respective patient groups. The sum of 3 venous level velocities resulted in the best cutoff for dichotomizing groups into normal versus slow venous flow. Qualitative slow venous flow in the lower extremities on Doppler sonography accurately correlates with quantitatively slower flow, and this preliminary evaluation suggests an associated mildly increased rate of subsequent DVT development in oncology patients. © 2017 by the American Institute of Ultrasound in Medicine.
Zhu, Shibai; Song, Yi; Chen, Xi; Qian, Wenwei
2018-04-10
Chinese herbal medicine has traditionally been considered to promote blood circulation to remove obstruction in the channels and clear pathogenic heat to drain dampness effects. We conducted this meta-analysis to evaluate its benefits for the prevention of deep venous thrombosis (DVT) after lower extremity orthopedic surgery. Relevant, published studies were identified using the following keywords: lower extremity orthopedic surgery, arthroplasty, joint replacement, fracture, traditional Chinese and western medicine, Chinese herbal medicine, deep venous thrombosis (DVT), and Venous thromboembolism (VTE). The following databases were used to identify the literature consisting of RCTs with a date of search of 31 May 2017: PubMed, Cochrane Library, Web of knowledge, the Chinese National Knowledge Infrastructure Database, the Chongqing VIP Database, the Chinese Biomedical Database, and the Wanfang Database (including three English and four Chinese databases). All relevant data were collected from studies meeting the inclusion criteria. The outcome variables were the incidence rate of DVT, activated partial thromboplastin time (APTT), prothrombin time (PT), and D-dimer; subcutaneous hematoma; and other reported outcomes. RevMan5.2. software was adopted for the meta-analysis. A total of 20 published studies (1862 cases) met the inclusion criteria. The experimental group, 910 patients (48.87%), received the Chinese herbal medicine or traditional Chinese and western medicine for prevention of DVT; the control group, 952 patients (51.13%), received the standard western treatment. The meta-analysis showed that traditional Chinese and western medicine therapy reduced the incidence rates of DVT significantly when compared with controls (risk ratio [RR] = 0.40; 95% CI, 0.30 to 0.54; P < 0.00001), and the D-dimer was lower in the experimental group (P = 0.01). Besides, the incidence rate of subcutaneous hematoma was lower in the experimental group (P < 0.0001). However, no significant difference was found in the PT (P = 0.98) and APTT (P = 0.75) in two groups. No serious adverse events were reported. Traditional Chinese and western medicine therapy may be a safe, effective prevention modality for DVT after lower extremity orthopedic surgery. Further rigorously designed, randomized trials are warranted.
NASA Astrophysics Data System (ADS)
Muthusamy, K.; Fadzil, M. Y.; Nazrin Akmal, A. Z. Muhammad; Ahmad, S. Wan; Nur Azzimah, Z.; Hanafi, H. Mohd; Mohamad Hafizuddin, R.
2018-04-01
Both oil palm shell (OPS) and fly ash are by-product generated from the industries. Disposal of these by-product as wastes cause negative impact to the environment. The use of both oil palm shell and fly ash in concrete is seen as an economical solution for making green and denser concrete. The primary aim of this research is to determine the effects of FA utilization as sand replacement in oil palm shell lightweight aggregate concrete (OPS LWAC) towards sulphate resistance. Five concrete mixes containing fly ash as sand replacement namely 0%, 10%, 20%, 30% and 40% were prepared in these experimental work. All mixes were cast in form of cubes before subjected to sulphate solution for the period of 5 months. It was found that addition of 10% fly ash as sand replacement content resulted in better sulphate resistance of OPS LWAC. The occurrence of pozzolanic reaction due to the presence of FA in concrete has consumed the vulnerable Calcium hydroxide to be secondary C-S-H gel making the concrete denser and more durable.
Kim, Hwang-Hee; Kim, Chun-Soo; Jeon, Ji-Hong; Park, Chan-Gi
2016-01-29
To evaluate the effects of industrial by-products materials on the performance of porous concrete for plant growth, this study investigated the physical, strength, and freeze/thaw resistances of porous concrete for plant growth, prepared by replacing cement with blast furnace slag powder at 60% by weight, and replacing natural stone aggregates with coarse blast furnace slag aggregates at rates of 0%, 20%, 40%, 60% and 100% by weight. In addition, the effects of adding natural jute fiber and styrene butadiene ( SB) latex to these concrete mixtures were evaluated. The void ratio, compressive strength, and freeze/thaw resistance of the samples were measured. With increasing replacement rate of blast furnace aggregates, addition of latex, and mixing of natural jute fiber the void ratio of the concrete was increased. Compressive strength decreased as the replacement rate of blast-furnace slag aggregates increased. The compressive strength decreased after 100 freeze/thaw cycles, regardless of the replacement rate of blast furnace slag aggregates or of the addition of natural jute fiber and latex. The addition of natural jute fiber and latex decreased the compressive strength after 100 freeze/thaw cycles. The test results indicate that the control mixture satisfied the target compressive strength of 10 MPa and the target void ratio of 25% at replacement rates of 0% and 20% for blast furnace aggregates, and that the mixtures containing latex satisfied the criteria up to an aggregate replacement rate of 60%. However, the mixtures containing natural jute fiber did not satisfy these criteria. The relationship between void ratio and residual compressive strength after 100 freeze/thaw cycles indicates that the control mixture and the mixtures containing jute fiber at aggregate replacement rates of 20% and 40% satisfied the target void ratio of 25% and the target residual compressive strength of over 80% after 100 freeze/thaw cycles. The mixtures containing latex and aggregate replacement rates up to 60% satisfied the target void ratio and compressive strength.
Kim, Hwang-Hee; Kim, Chun-Soo; Jeon, Ji-Hong; Park, Chan-Gi
2016-01-01
To evaluate the effects of industrial by-products materials on the performance of porous concrete for plant growth, this study investigated the physical, strength, and freeze/thaw resistances of porous concrete for plant growth, prepared by replacing cement with blast furnace slag powder at 60% by weight, and replacing natural stone aggregates with coarse blast furnace slag aggregates at rates of 0%, 20%, 40%, 60% and 100% by weight. In addition, the effects of adding natural jute fiber and styrene butadiene (SB) latex to these concrete mixtures were evaluated. The void ratio, compressive strength, and freeze/thaw resistance of the samples were measured. With increasing replacement rate of blast furnace aggregates, addition of latex, and mixing of natural jute fiber the void ratio of the concrete was increased. Compressive strength decreased as the replacement rate of blast-furnace slag aggregates increased. The compressive strength decreased after 100 freeze/thaw cycles, regardless of the replacement rate of blast furnace slag aggregates or of the addition of natural jute fiber and latex. The addition of natural jute fiber and latex decreased the compressive strength after 100 freeze/thaw cycles. The test results indicate that the control mixture satisfied the target compressive strength of 10 MPa and the target void ratio of 25% at replacement rates of 0% and 20% for blast furnace aggregates, and that the mixtures containing latex satisfied the criteria up to an aggregate replacement rate of 60%. However, the mixtures containing natural jute fiber did not satisfy these criteria. The relationship between void ratio and residual compressive strength after 100 freeze/thaw cycles indicates that the control mixture and the mixtures containing jute fiber at aggregate replacement rates of 20% and 40% satisfied the target void ratio of 25% and the target residual compressive strength of over 80% after 100 freeze/thaw cycles. The mixtures containing latex and aggregate replacement rates up to 60% satisfied the target void ratio and compressive strength. PMID:28787883
Current concepts in repair of extremity venous injury.
Williams, Timothy K; Clouse, W Darrin
2016-04-01
Extremity venous injury management remains controversial. The purpose of this communication is to offer perspective as well as experiential and technical insight into extremity venous injury repair. Available literature is reviewed and discussed. Historical context is provided. Indication, the decision process for repair, including technical conduct, is delineated. In particular, the authors' experiences in both civilian and wartime injury are used for perspective. Extremity venous injury repair was championed within data from the Vietnam Vascular Registry. However, patterns of extremity venous injury differ between combat and civilian settings. Since Vietnam, civilian descriptive series opine the benefits and potential complications associated with both venous injury repair and ligation. These surround extremity edema, chronic venous insufficiency, thromboembolism, and limb loss. Whereas no clear superiority in either approach has been identified to date, there appears to be no increased risk of pulmonary embolism or chronic venous changes with repair. Newer data from the wars in Iraq and Afghanistan and meta-analysis have reinforced this and also have suggested limb salvage benefit for extremity venous repair in combined arterial and venous injuries in modern settings. The patient's physiologic state and associated injury drive five triage categories suggesting vein injury management. Vein repair thrombosis occurs in a significant proportion, yet many recanalize and possibly have a positive impact on limb venous return. Further, early decompression favors reduced blood loss, acute edema, and inflammation, supporting collateral development. Large soft tissue injury minimizing collateral capacity increases the importance of repair. Constructs of repair are varied with modest differences in patency. Venous shunting is feasible, but specific roles remain nebulous. An aggressive posture toward extremity venous injury repair seems justified today because of the likely role in reducing venous hypertensive sequelae as well as a potential role in limb salvage. Appropriate triage selection for extremity vein repair is essential. Copyright © 2016 Society for Vascular Surgery. All rights reserved.
Naik, Rakhi P.; Streiff, Michael B.; Haywood, Carlton; Nelson, Julie A.; Lanzkron, Sophie
2013-01-01
BACKGROUND Sickle cell disease is recognized as a hypercoagulable state; however the frequency and characteristics of venous thromboembolism in sickle cell patients have not been well-defined. PURPOSE To establish the prevalence and risk factors for venous thromboembolism in a large cohort of patients with sickle cell disease and determine the relationship between venous thromboembolism and mortality. METHODS We performed a cross-sectional study of 404 sickle cell disease patients cared for at the Sickle Cell Center for Adults at Johns Hopkins. Demographic, sickle cell disease-specific comorbidity, and venous thromboembolism data were collected on all patients. RESULTS 101 patients (25%) had a history of venous thromboembolism with a median age at diagnosis of 29.9 years. A history of non-catheter-related venous thromboembolism was found in 18.8% of patients. Sickle variant genotypes conferred a higher risk of non-catheter-related venous thromboembolism compared to sickle cell anemia genotypes (SS/Sβ0) (relative risk (RR) 1.77, 95% confidence interval (CI) 1.18–2.66). Tricuspid regurgitant jet velocity ≥ 2.5 m/s was also associated with non-catheter-related venous thromboembolism (RR 1.65, CI 1.12–2.45). Thirty patients (7.4%) died during the study period. Adjusting for all variables, non-catheter-related venous thromboembolism was independently correlated with death (RR 3.63, CI 1.66–7.92). CONCLUSION Venous thromboembolism is common in adults with sickle cell disease. Sickle variant genotypes and tricuspid regurgitant jet velocity ≥ 2.5m/s are associated with non-catheter-related venous thromboembolism. In addition, non-catheter-related venous thromboembolism appears to be an independent risk factor for death in our cohort. These results suggest that disease-specific prophylaxis and treatment strategies for venous thromboembolism should be investigated in sickle cell disease patients. PMID:23582935
Baltsavias, Gerasimos; Spiessberger, Alex; Hothorn, Torsten; Valavanis, Anton
2015-04-01
Cranial dural arteriovenous fistulae have been classified into high- and low-risk lesions mainly based on the pattern of venous drainage. Those with leptomeningeal venous drainage carry a higher risk of an aggressive clinical presentation. Recently, it has been proposed that the clinical presentation should be considered as an additional independent factor determining the clinical course of these lesions. However, dural shunts with leptomeningeal venous drainage include a very wide spectrum of inhomogeneous lesions. In the current study, we correlated the clinical presentation of 107 consecutive patients harboring cranial dural arteriovenous shunts with leptomeningeal venous drainage, with their distinct anatomic and angiographic features categorized into eight groups based on the "DES" (Directness and Exclusivity of leptomeningeal venous drainage and features of venous Strain) concept. We found that among these groups, there are significant angioarchitectural differences, which are reflected by considerable differences in clinical presentation. Leptomeningeal venous drainage of dural sinus shunts that is neither direct nor exclusive and without venous strain manifested only benign symptoms (aggressive presentation 0%). On the other end of the spectrum, the bridging vein shunts with direct and exclusive leptomeningeal venous drainage and venous strain are expected to present aggressive symptoms almost always and most likely with bleeding (aggressive presentation 91.5%). Important aspects of the above correlations are discussed. Therefore, the consideration of leptomeningeal venous drainage alone, for prediction of the clinical presentation of these shunts appears insufficient. Angiographic analysis based on the above concept, offers the possibility to distinguish the higher- from the lower-risk types of leptomeningeal venous drainage. In this context, consideration of the clinical presentation as an additional independent factor for the prediction of their clinical course seems superfluous and possibly misleading. Topography is connected to the clinical presentation of the dural shunts inasmuch as the former determines the venous anatomy and the angioarchitectural features of the lesions.
NASA Astrophysics Data System (ADS)
Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.
2016-02-01
Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weisiger, R.A.; Mendel, C.M.; Cavalieri, R.R.
1986-03-01
Two general models have been proposed for predicting the effects of metabolism, protein binding, and plasma flow on the removal of drugs by the liver. These models differ in the degree of plasma mixing assumed to exist within each hepatic sinusoid. The venous equilibrium model treats the sinusoid as a single well-stirred compartment, whereas the sinusoidal model effectively breaks up the sinusoid into a large number of sequentially perfused compartments which do not exchange their contents except through plasma flow. As a consequence, the sinusoidal model, but not the venous equilibrium model, predicts that the concentration of highly extracted drugsmore » will decline as the plasma flows through the hepatic lobule. To determine which of these alternative models best describes the hepatic uptake process, we looked for evidence that concentration gradients are formed during the uptake of (/sup 125/I)thyroxine by the perfused rat liver. Autoradiography of tissue slices after perfusion of the portal vein at physiologic flow rates with protein-free buffer containing (/sup 125/I)thyroxine demonstrated a rapid exponential fall in grain density with distance from the portal venule, declining by half for each 8% of the mean length of the sinusoid. Reversing the direction of perfusate flow reversed the direction of the autoradiographic gradients, indicating that they primarily reflect differences in the concentration of thyroxine within the hepatic sinusoids rather than differences in the uptake capacity of portal and central hepatocytes. Analysis of the data using models in which each sinusoid was represented by different numbers of sequentially perfused compartments (1-20) indicated that at least eight compartments were necessary to account for the magnitude of the gradients seen.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norbash, A.M.; Marks, M.P.; Lane, B.
1994-05-01
To determine whether there is a physiologic explanation for the predisposition of patients with certain angiographic characteristics to symptoms of hemorrhage and steal. Superselective transcatheter feeding arterial pressure and mean arterial pressure measurements were obtained before embolotherapy in 32 patients with cerebral arteriovenous malformations. Pressures were correlated with previously described angioarchitectural characteristics predisposing to hemorrhage and steal. These included size of the arteriovenous malformation, feeding artery length, venous drainage pattern, and angiomatous change. The feeding arterial pressure and feeding arterial pressure/mean arterial pressure ratios were significantly decreased in patients with angiomatous change. Feeding arterial pressure and feeding arterial pressure/mean arterialmore » pressure ratios progressively decreased as lesions went from peripheral, to mixed, to central venous drainage. A trend for lower feeding arterial pressure was also demonstrated with greater feeding pedicle length. A statistically significant correlation could not be demonstrated between feeding arterial pressure or feeding arterial pressure/mean arterial pressure ratios and size of the arteriovenous malformation, hemorrhage, or symptoms of steal. Feeding arterial pressure measurements help provide a physiologic basis for the relationship between certain angiographic characteristics and hemorrhage and steal symptoms in patients with arteriovenous malformation. 27 refs., 1 fig.« less
[Changes in PCO2 and pH gradients in a canine model of experimental acute hemorrhage].
Rabanal, J M; Mons, R; Galindo, M; Solares, G; Seco, I; García-Castrillo, L
1999-01-01
To study changes in arterial-venous PCO2 pressures (Da-vPCO2) and in pH (Da-vpH) in an experimental dog model of acute bleeding. To emphasize the utility of monitoring these variables in situations of acute bleeding. ANIMALS AND METHOD: Eighteen dogs were anesthesized and monitored while being subjected to gradual bleeding. Gasometric and hemodynamic variables were recorded at the following moments: baseline, stage I (15% of volemic loss), stage Ib (20%), stage II (25%), stage IIb (30%) and stage III (35%). No significant differences in pH or PCO2 in either arterial or mixed venous blood were found. Bleeding induced a constant and progressive increase in Da-vPCO2 that correlated with changes in volume (r = -0.56, p < 0.001), SvO2 (r = 0.71; p < 0.001), Da-vO2 gradient (r = 0.62; p < 0.001) and cardiac output (r = 0.63; p < 0.001). Gradual bleeding caused a constant and significant increase of Da-vPCO2. Monitoring such changes in states of circulatory insufficiency may be useful for evaluating tissue ischemia.
Young, William F; Stanson, Anthony W
2009-01-01
Adrenal venous sampling (AVS) is the criterion standard to distinguish between unilateral and bilateral adrenal disease in patients with primary aldosteronism. The keys to successful AVS include appropriate patient selection, careful patient preparation, focused technical expertise, defined protocol, and accurate data interpretation. The use of AVS should be based on patient preferences, patient age, clinical comorbidities, and the clinical probability of finding an aldosterone-producing adenoma. AVS is optimally performed in the fasting state in the morning. AVS is an intricate procedure because the right adrenal vein is small and may be difficult to locate - the success rate depends on the proficiency of the angiographer. The key factors that determine the successful catheterization of both adrenal veins are experience, dedication and repetition. With experience, and focusing the expertise to 1 or 2 radiologists at a referral centre, the AVS success rate can be as high as 96%. A centre-specific, written protocol is mandatory. The protocol should be developed by an interested group of endocrinologists, radiologists and laboratory personnel. Safeguards should be in place to prevent mislabelling of the blood tubes in the radiology suite and to prevent sample mix-up in the laboratory.
Atchison, Christie M; Amankwah, Ernest; Wilhelm, Jean; Arlikar, Shilpa; Branchford, Brian R; Stock, Arabela; Streiff, Michael; Takemoto, Clifford; Ayala, Irmel; Everett, Allen; Stapleton, Gary; Jacobs, Marshall L; Jacobs, Jeffrey P; Goldenberg, Neil A
2018-02-01
Paediatric hospital-associated venous thromboembolism is a leading quality and safety concern at children's hospitals. The aim of this study was to determine risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or therapeutic cardiac catheterisation. We conducted a retrospective, case-control study of children admitted to the cardiovascular intensive care unit at Johns Hopkins All Children's Hospital (St. Petersburg, Florida, United States of America) from 2006 to 2013. Hospital-associated venous thromboembolism cases were identified based on ICD-9 discharge codes and validated using radiological record review. We randomly selected two contemporaneous cardiovascular intensive care unit controls without hospital-associated venous thromboembolism for each hospital-associated venous thromboembolism case, and limited the study population to patients who had undergone cardiothoracic surgery or therapeutic cardiac catheterisation. Odds ratios and 95% confidence intervals for associations between putative risk factors and hospital-associated venous thromboembolism were determined using univariate and multivariate logistic regression. Among 2718 admissions to the cardiovascular intensive care unit during the study period, 65 met the criteria for hospital-associated venous thromboembolism (occurrence rate, 2%). Restriction to cases and controls having undergone the procedures of interest yielded a final study population of 57 hospital-associated venous thromboembolism cases and 76 controls. In a multiple logistic regression model, major infection (odds ratio=5.77, 95% confidence interval=1.06-31.4), age ⩽1 year (odds ratio=6.75, 95% confidence interval=1.13-160), and central venous catheterisation (odds ratio=7.36, 95% confidence interval=1.13-47.8) were found to be statistically significant independent risk factors for hospital-associated venous thromboembolism in these children. Patients with all three factors had a markedly increased post-test probability of having hospital-associated venous thromboembolism. Major infection, infancy, and central venous catheterisation are independent risk factors for hospital-associated venous thromboembolism in critically ill children following cardiothoracic surgery or cardiac catheter-based intervention, which, in combination, define a high-risk group for hospital-associated venous thromboembolism.
Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P
2006-11-01
Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.
USDA-ARS?s Scientific Manuscript database
Study objectives were to evaluate the effects of post-weaning transport during heat stress (HS) and thermoneutral (TN) conditions when dietary antibiotics are removed or replaced with a nutraceutical. Sixty mixed sex piglets from 10 sows (n = 6 piglets/sow) were weaned (18.8 ± 0.8 d of age) and then...
Non-contact imaging of venous compliance in humans using an RGB camera
NASA Astrophysics Data System (ADS)
Nakano, Kazuya; Satoh, Ryota; Hoshi, Akira; Matsuda, Ryohei; Suzuki, Hiroyuki; Nishidate, Izumi
2015-04-01
We propose a technique for non-contact imaging of venous compliance that uses the red, green, and blue (RGB) camera. Any change in blood concentration is estimated from an RGB image of the skin, and a regression formula is calculated from that change. Venous compliance is obtained from a differential form of the regression formula. In vivo experiments with human subjects confirmed that the proposed method does differentiate the venous compliances among individuals. In addition, the image of venous compliance is obtained by performing the above procedures for each pixel. Thus, we can measure venous compliance without physical contact with sensors and, from the resulting images, observe the spatial distribution of venous compliance, which correlates with the distribution of veins.
Alibaz-Oner, Fatma; Aldag, Belgin; Aldag, Mustafa; Unal, A Ugur; Mutiş, Aydan; Toptas, Tayfur; Ergun, Tulin; Direskeneli, Haner
2016-07-01
Deep venous thrombosis (DVT) is the most common form of vascular involvement in Behçet's disease (BD). Chronic post-thrombotic syndrome (PTS) develops in up to one-half of patients with DVT and is associated with impaired quality of life (QoL). There are no data on the severity of DVT-related PTS and its effect on QoL in patients with vascular BD (VBD). We aimed to evaluate PTS and venous disease-specific QoL in patients with VBD. This study included 50 patients (41 men, nine women) with VBD and 31 individuals matched for age and gender (22 men, nine women) with DVT associated with non-BD causes. The Villalta scale was used to assess PTS. The Venous Disability Score and the Venous Clinical Severity Score were used for the assessment of venous disease. Venous disease-specific QoL was measured through Venous Insufficiency Epidemiological and Economic Study Quality of Life/Symptom (VEINES-QoL/Sym) questionnaire. The Behçet Syndrome Activity Score (BSAS) questionnaire was used to assess disease activity. We observed a significantly lower risk of PTS together with significantly better VEINES-QoL/Sym, and Venous Disability Score in the VBD group compared with the non-BD group. When VBD patients with PTS were compared with patients without PTS, VEINES-QoL/Sym, and Venous Clinical Severity Score were significantly worse. BSAS was also significantly higher in patients with PTS. An inverse correlation was found between the VEINES-QoL and the BSAS in multivariate analysis. There were no differences between anticoagulant users and nonusers regarding the presence of PTS and scores of all of the venous assessment tools. We found lower PTS risk and better venous disease-specific QoL, symptom severity, and venous disability scores in VBD patients compared with the non-BD group. Venous disease-specific QoL negatively correlated with disease activity. Effective control of vascular inflammation through treatment in VBD might explain lower rates of PTS and better venous QoL outcomes in VBD patients. Our results suggest that successful control of BD activity might decrease the development of PTS, improve venous disease-specific QoL, and prevent relapses in VBD. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Losonczy, Hajna; Nagy, Ágnes; Tar, Attila
2016-02-07
Cancer patients have a 2-7 fold increased risk of venous thromboembolism compared with the general population and, since 1990, this is associated with significant morbidity and mortality. This review summarizes the current knowledge on venous thromboembolism and cancer. Notably, the risk of venous thromboembolism varies depending on the type and stage of cancer. For instance, pancreatic and brain cancer patients have a higher risk of venous thromboembolism than breast and prostate cancer patients. Moreover, patients with metastatic disease have a higher risk than those with localized tumors. Tumor-derived procoagulant factors, cytokines and growth factors may directly and indirectly enhance venous thromboembolism. Chemotherapy produces ~6,5 fold increase in venous thromboembolism incidence in cancer patients compared to the general population. Prevention of this complication is challenging. The authors review the development of guidelines concerning venous thromboembolism prevention in hospitalized and also in ambulatory cancer patients treated with chemotherapy. Current guidelines recommend the use of low-molecular-weight heparin. Understanding the underlying mechanisms may allow the development of new therapies to safely prevent venous thromboembolism in cancer patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2017-06-19
Modifying the surface chemistry of materials by aluminization can protect vulnerable materials from corroding in harsh environments. The industry deals with corrosion issues is to regularly inspect components and replace them with corrosion resistant components.
Fan, Chengming; Yang, Yifeng; Xiong, Lian; Yin, Ni; Wu, Qin; Tang, Mi; Yang, Jinfu
2017-02-23
To evaluate the early and mid-term results of pulmonary trunk reconstruction using a technique in which autogenous tissue is preserved in situ in pulmonary atresia patients with a ventricular septal defect (PA-VSD). The pulmonary artery was reconstructed using autogenous tissue that had been preserved in situ and a bovine jugular venous patch in 24 patients who were diagnosed with PA-VSD (the observation group). The traditional operation using a bovine jugular venous conduit was performed in 40 other cases of PA-VSD (the control group). In the observation group, all patients survived and recovered successfully without complications. Follow-up echocardiography 2-10 years after the procedure showed that the reconstructed right ventricular outflow tract (RVOT) and pulmonary artery were patent, showing no evidence of flow obstruction. Only mild regurgitation of the bovine jugular vein valve was observed. In the control group, early postoperative death occurred in two cases. Another two patients had obstruction of the anastomotic stoma and underwent conduit replacement surgery within 2 weeks of the initial procedure. During the 2-10 years of follow-up care, six patients presented with valvular stenosis of the BJVC, with a pressure gradient of more than 50 mmHg. The technique for preserving autogenous tissue to reconstruct the pulmonary posterior wall is a satisfactory method for treating PA-VSD.
Vergara, Teresa; Véliz, Elena; Fica, Alberto; Leiva, Jordan
2017-08-01
There is no consensus definition to distinguish infectious from non-infectious phlebitis associated to peripheral venous catheter. To evaluate the impact of an intervention program on the rate of infectious (those associated to bacteremia or local purulent discharge) and non-infectious phlebitis (the rest) and identify differential features. Interventional study developed in three stages: basal measurement, intervention, and evaluation. Ten infectious and 186 non-infectious phlebitis were registered. Infectious phlebitis diminished after intervention (0.2 to 0.04 events per 1,000 bed-days; p = 0.02) but not the rest (2.3 per 1,000 bed-days before and after). Five of 10 patients with infectious phlebitis had bacteremia, one with infectious endocarditis and valve replacement, and other with septic shock and a fatal outcome. None of the patients in the non-infectious group presented complications. Infectious phlebitis appeared later (mean 4.1 versus 2.4 days; p = 0.007) and were associated to fever (40% vs 5.9%, p = 0.004). Non-infectious phlebitis was associated to irritating compounds (OR 6.1; IC95 1.3-29, p < 0.05). The intervention program demonstrated a favorable impact only on the rate of infectious phlebitis. Distinction appears to be relevant because those of infectious origin are associated with fever, complications or death, respond to an intervention program, and emerge lately.
Pathophysiology and Toxicokinetic Studies of Blue-Green Algae Intoxication in the Swine Model
1991-06-26
perfusion, renal perfusion, and mean arterial and central venous pressures were decreased, and portal pressure increased. Liver iron and hemoglobin indicated...the lethal dose, aortic mean pressure and central venous pressure decreased significantly, while portal venous pressure significantly increased. The...8217" recorded on a poiygraphY and logged on a hemodynamic analyzer. Mean aortic, central venous , and portal venous pressures were determined predosing
Aguiar de Sousa, Diana; Canhão, Patrícia; Crassard, Isabelle; Coutinho, Jonathan; Arauz, Antonio; Conforto, Adriana; Béjot, Yannick; Giroud, Maurice; Ferro, José M
2017-11-01
Pregnancy is associated with increased risk of venous thrombotic events, including cerebral venous thrombosis. We aimed to study the complications and outcome of subsequent pregnancies in women with previous cerebral venous thrombosis. Follow-up study of women with acute cerebral venous thrombosis at childbearing age included in a previously described cohort (International Study of Cerebral Vein and Dural Sinus Thrombosis). Patients were interviewed by local neurologists to assess rate of venous thrombotic events, pregnancy outcomes, and antithrombotic prophylaxis during subsequent pregnancies. A total of 119 women were included, with a median follow-up of 14 years. Eighty-two new pregnancies occurred in 47 women. In 83% (68 of 82), some form of antithrombotic prophylaxis was given during at least 1 trimester of pregnancy or puerperium. Venous thrombotic events occurred in 3 pregnancies, including 1 recurrent cerebral venous thrombosis. Two of the 3 women were on prophylactic low-molecular-weight heparin at the time of the event. Outcomes of pregnancies were 51 full-term newborns, 9 preterm births, 2 stillbirths, and 20 abortions (14 spontaneous). In women with prior cerebral venous thrombosis, recurrent venous thrombotic events during subsequent pregnancies are infrequent. © 2017 American Heart Association, Inc.
Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L
2013-07-01
The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The complicated role of venous drainage on the survival of arterialized venous flaps
Weng, Weidong; Zhang, Feng; Zhao, Bin; Wu, Zhipeng; Gao, Weiyang; Li, Zhijie; Yan, Hede
2017-01-01
The arterialized venous flap (AVF) has been gradually popularized in clinical settings; however, its survival is still inconsistent and the role of venous drainage remains elusive. In this study, we aimed to investigate the role of venous drainage on the flap survival of arterialized venous flaps. An arterialized venous flap was outlined symmetrically in the rabbit abdomen. The arterial perfusion flap with a unilateral vascular pedicle was taken as the control group and three other experimental groups (I, II and III) were designed based on the number of drainage veins (n = 1, 2 and 3 in the three groups, respectively). Compared with the control group, significant venous congestion was noted in all the experimental groups and the most severe one was seen in group I; while no statistical difference was observed between groups II and III. Similar results regarding blood perfusion state, epidermal metabolite levels and flap survival status were obtained among the three groups. These findings suggested that venous drainage is vital in the survival of the flap, but unlike in the arterial perfusion flaps, the problem of venous congestion can only be partially solved by increasing the number of draining veins. Further studies are warranted to gain insight into this complicated issue. PMID:28145882
Tewari, Mallika
2016-12-01
Pancreaticoduodenectomy with superior mesenteric/portal venous resection for pancreatic ductal adenocarcinoma (PDAC) is frequently performed with no added morbidity or mortality in case of tumor abutment to the superior mesenteric or portal vein so as to obtain a margin negative resection. True histopathological portal vein invasion is found only in a small subset of such patients. The aim of this review aimed to discuss the significance of histopathological venous invasion in PDAC. For this review available data was searched from PubMed and analyzed. No randomized trials have been published on this topic. Existing data on prognostic factors in histopathological venous invasion by PDAC are limited and recent studies indicate worse survival in this subgroup of patients. In addition, venous invasion in PDAC has been associated with large tumors, involved lymph nodes, perineural invasion and R1 resection. The survival of patients with portal venous resection but without histologic venous invasion is reportedly better than those with histopathological venous invasion; though conflicting studies do exist on the subject. Some studies also relate the depth of venous invasion to prognosis after surgical resection of PDAC. Frank/'histopathological' invasion of superior mesenteric/portal venous and R1 resection indicate a very poor survival. Such patients may be given the opportunity of benefit of neoadjuvant treatment.
Mackintosh, Stephen; Buchanan, Samantha; Schwarzenlander, Kerstin; De Ruyter, Bernadette
2017-01-01
Objectives We investigated popliteal venous haemodynamics of the VenaJet Jet Impulse Technology system within a below-knee fibreglass cast. Design Randomized controlled trial. Participants Twenty-four healthy participants aged 18–54 had both feet placed within the Jet Impulse Technology system and were randomised for one or other leg to be within a below-knee fibreglass cast. Setting Pacific Radiology, Lower Hutt, Wellington Main outcome measures The primary outcome variable was peak systolic velocity (cm/s) compared between legs with and without the cast at 60 min (after 10 min Jet Impulse Technology activation), using a mixed linear model and a non-inferiority bound of 4.8 cm/s. Secondary outcome variables were the difference in peak systolic velocity between the casted limb and the non-casted limb at baseline and 40 min after casting, and the difference in mean flow velocity (cm/s), vein diameter (mm), and total volume flow (L/min) between the casted limb and the non-casted limb at baseline, 40 and 60 min. Results The mean (standard deviation) peak systolic velocity was 4.6(1.5), 4.8(1.1), 28.8(16.1), and 4.3(1.2), 4.8(1.4) and 29.3(19.0) cm/s at baseline, 40 and 60 min in the casted and non-casted leg, respectively. The difference (95% confidence interval) between cast and no-cast at 60 min was −0.8 (−6.5 to 4.9) cm/s, P = 0.78. The peak systolic velocity, flow velocity and total volume flow at 40 min were not statistically significantly different from baseline for both casted and non-casted limb. Conclusion In healthy volunteers, the popliteal venous haemodynamics of the Jet Impulse Technology system was similar between the legs with and without a below-knee fibreglass cast. In-cast Jet Impulse Technology may provide a non-pharmacological option for venous thromboembolism prophylaxis for lower-limb cast-immobility. PMID:28203384
Jansen, Joris A; Lameijer, Joost R C; Snoeker, Barbara A M
2017-10-01
The aims of this study were to investigate the safety of combined intravenous, oral and topical tranexamic acid (TXA) in primary total knee replacement. We assessed dose-related efficacy on hemoglobin level, transfusion, length of stay and thromboembolic complications. In addition, TXA safety in patients with previous history of thromboembolism >12months ago was monitored specifically. From January 2013 until January 2016, 922 patients were included who received TXA after primary total knee replacement. Patients without TXA administration or with thromboembolic events <12months ago were excluded. TXA dosage groups were divided into ≤10mg/kg, >10-25mg/kg and >25-50mg/kg. Between the three TXA groups no significant difference was found in thromboembolic complications (deep venous thrombosis (DVT) and pulmonary embolism (PE)), wound leakage and transfusion rate. For patients with DVT or PE in their history >12months ago specifically, no more complications were noted in higher-TXA-dosage groups compared to the low-dosage group. Length of stay was shorter in the highest-TXA-dosage group compared with lower-dosage groups (median two vs three days). With high TXA dose a smaller difference between pre- and postoperative Hb was found: the >25-50mg/kg TXA group had a 0.419mmol/l smaller decrease in postoperative hemoglobin compared to the lowest-dosage group (P<0.05). Combined intravenous, oral and topical TXA is effective in knee replacement and can safely be given to patients with a thromboembolic history >12months ago. High dosage (>25-50mg/kg) TXA resulted in the smallest decrease in postoperative hemoglobin. Copyright © 2017 Elsevier B.V. All rights reserved.
Kosel, Juliusz; Rusak, Małgorzata; Gołembiewski, Łukasz; Dąbrowska, Milena; Siemiątkowski, Andrzej
2016-01-01
Among the many changes caused by a surgical insult one of the least studied is postoperative immunosuppression. This phenomenon is an important cause of infectious complications of surgery such as surgical site infection or hospital acquired pneumonia. One of the mechanisms leading to postoperative immunosuppression is the apoptosis of immunological cells. Anesthesia during surgery is intended to minimize harmful changes and maintain perioperative homeostasis. The aim of the study was evaluation of the effect of the anesthetic technique used for total knee replacement on postoperative peripheral blood lymphocyte apoptosis. 34 patients undergoing primary total knee replacement were randomly assigned to two regional anesthetic protocols: spinal anesthesia and combined spinal-epidural anesthesia. 11 patients undergoing total knee replacement under general anesthesia served as control group. Before surgery, immediately after surgery, during first postoperative day and seven days after the surgery venous blood samples were taken and the immunological status of the patient was assessed with the use of flow cytometry, along with lymphocyte apoptosis using fluorescent microscopy. Peripheral blood lymphocyte apoptosis was seen immediately in the postoperative period and was accompanied by a decrease of the number of T cells and B cells. There were no significant differences in the number of apoptotic lymphocytes according to the anesthetic protocol. Changes in the number of T CD3/8 cells and the number of apoptotic lymphocytes were seen on the seventh day after surgery. Peripheral blood lymphocyte apoptosis is an early event in the postoperative period that lasts up to seven days and is not affected by the choice of the anesthetic technique. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Validation of Risk Assessment Models of Venous Thromboembolism in Hospitalized Medical Patients.
Greene, M Todd; Spyropoulos, Alex C; Chopra, Vineet; Grant, Paul J; Kaatz, Scott; Bernstein, Steven J; Flanders, Scott A
2016-09-01
Patients hospitalized for acute medical illness are at increased risk for venous thromboembolism. Although risk assessment is recommended and several at-admission risk assessment models have been developed, these have not been adequately derived or externally validated. Therefore, an optimal approach to evaluate venous thromboembolism risk in medical patients is not known. We conducted an external validation study of existing venous thromboembolism risk assessment models using data collected on 63,548 hospitalized medical patients as part of the Michigan Hospital Medicine Safety (HMS) Consortium. For each patient, cumulative venous thromboembolism risk scores and risk categories were calculated. Cox regression models were used to quantify the association between venous thromboembolism events and assigned risk categories. Model discrimination was assessed using Harrell's C-index. Venous thromboembolism incidence in hospitalized medical patients is low (1%). Although existing risk assessment models demonstrate good calibration (hazard ratios for "at-risk" range 2.97-3.59), model discrimination is generally poor for all risk assessment models (C-index range 0.58-0.64). The performance of several existing risk assessment models for predicting venous thromboembolism among acutely ill, hospitalized medical patients at admission is limited. Given the low venous thromboembolism incidence in this nonsurgical patient population, careful consideration of how best to utilize existing venous thromboembolism risk assessment models is necessary, and further development and validation of novel venous thromboembolism risk assessment models for this patient population may be warranted. Published by Elsevier Inc.
2013-01-01
Background The role of the extracranial venous system in the pathology of central nervous system (CNS) disorders and aging is largely unknown. It is acknowledged that the development of the venous system is subject to many variations and that these variations do not necessarily represent pathological findings. The idea has been changing with regards to the extracranial venous system. Discussion A range of extracranial venous abnormalities have recently been reported, which could be classified as structural/morphological, hemodynamic/functional and those determined only by the composite criteria and use of multimodal imaging. The presence of these abnormalities usually disrupts normal blood flow and is associated with the development of prominent collateral circulation. The etiology of these abnormalities may be related to embryologic developmental arrest, aging or other comorbidities. Several CNS disorders have been linked to the presence and severity of jugular venous reflux. Another composite criteria-based vascular condition named chronic cerebrospinal venous insufficiency (CCSVI) was recently introduced. CCSVI is characterized by abnormalities of the main extracranial cerebrospinal venous outflow routes that may interfere with normal venous outflow. Summary Additional research is needed to better define the role of the extracranial venous system in relation to CNS disorders and aging. The use of endovascular treatment for the correction of these extracranial venous abnormalities should be discouraged, until potential benefit is demonstrated in properly-designed, blinded, randomized and controlled clinical trials. Please see related editorial: http://www.biomedcentral.com/1741-7015/11/259. PMID:24344742
Does community-wide chronic kidney disease management improve patient outcomes?
Rayner, Hugh C; Baharani, Jyoti; Dasgupta, Indranil; Suresh, Vijayan; Temple, Robert M; Thomas, Mark E; Smith, Steve A
2014-03-01
The number of patients starting renal replacement therapy (RRT) is increasing in England, as it is worldwide. Improvements in the management of chronic kidney disease (CKD) across communities to alter this trend are a public health priority. We have prospectively studied changes in the incidence and modality of treatment for end-stage renal disease following the introduction of a CKD management programme in the West Midlands region of England. Nephrology service to approximately 700 000 adult population of mixed ethnicity in urban and suburban areas, many with social deprivation. The programme was introduced in stages between 2003 and 2006 and comprised primary care education and financial incentives, personal clinical reports written directly to patients following every consultation, routine laboratory estimated glomerular filtration rate (eGFR) reporting, eGFR graph surveillance to identify and monitor patients at risk, multidisciplinary pre-RRT care and conservative care. Prevalent patients: 10 552 with CKD and 8509 without CKD with diabetes. access to nephrology care, trends in RRT incidence and starting modality, place of death without RRT. Incident count was adjusted for changes in the local adult population recorded in national censuses. Ninety-one per cent of patients aged ≥75 years with incident CKD stage 5 were known to a nephrologist. The population-adjusted incident RRT rate peaked in 2005 and then declined; the proportion starting with transplant, peritoneal dialysis or haemodialysis by arterio-venous fistula increased to 63% by 2012 (P = 0.001 versus 2005). Fifty-two per cent of patients receiving planned conservative care without dialysis died out of hospital. Following the introduction of a community-wide systematic CKD management programme, the population-adjusted incidence of RRT reduced, modality of initiation of RRT improved and a majority of patients receiving planned conservative care without dialysis died out of hospital.
The dynamic volume changes of polymerising polymethyl methacrylate bone cement.
Muller, Scott D; Green, Sarah M; McCaskie, Andrew W
2002-12-01
The Swedish hip register found an increased risk of early revision of vacuum-mixed cemented total hip replacements. The influence of cement mixing technique on the dynamic volume change in polymerising PMMA is not well understood and may be relevant to this observation. Applying Archimedes' principle, we have investigated the dynamic volume changes in polymerising cement and determined the influence of mixing technique. All specimens showed an overall volume reduction: hand-mixed 3.4% and vacuum-mixed 6.0%. Regression analysis of sectional porosity and volume reduction showed a highly significant relationship. Hand-mixed porous cement showed a transient volume increase before solidification. However, vacuum-mixed cement showed a progressive volume reduction throughout polymerisation. Transient expansion of porous cement occurs at the critical time of micro-interlock formation, possibly improving fixation. Conversely, progressive volume reduction of vacuum-mixed cement throughout the formation of interlock may damage fixation. Stable fixation of vacuum-mixed cement may depend on additional techniques to offset the altered volumetric behaviour of vacuum-mixed cement.
Wong, Y S; Chung, K L Y; Lo, K W Y; Liu, C S W; Fan, T W; Tse, S K S; Tang, P M Y; Chao, N S Y; Liu, K K W; Leung, M W Y
2014-01-01
Anatomical variations on venous drainage in varicoceles are under-reported. We report our experience in scrotal antegrade sclerotherapy (SAS) for adolescent varicoceles. Since 2011, 15 consecutive boys with left varicoceles were recruited. Under general anaesthesia, a 5-mm transverse incision was made at scrotal neck, testicular vein was cannulated at pampiniform plexus with venogram performed. Foam sclerosant by mixing sodium tetradecyl sulphate (STS), Lipiodol(®) and air was slowly injected under fluoroscopy. Postoperatively the patients were followed-up for varicocele grading, testicular size, and complications. Median age at operation was 14 (10-19) years. 80 % had grade three varicoceles, 33.3 % had smaller left testis before operation. Intra-operative venogram showed three different anatomical variations. Group I: eleven patients (73.3 %) had single distinct internal spermatic vein; Group II: two patients demonstrated duplication of internal spermatic vein draining into left renal vein; Group III: two patients had pampiniform plexus draining to iliac and/or paraspinal veins. SAS was performed in Group I and II patients. Sclerosant volume injected ranged from 1.5 to 4.5 ml. In Group III patients, surgical ligation of testicular veins was performed rather than SAS to avoid uncontrolled systemic sclerosant spillage. Mean length of stay was 1.13 day. One patient with scrotal haematoma and one other with minor wound dehiscence were managed conservatively. Mean follow-up period was 10.9 (1-22) months. Thirteen patients (86.7 %) achieved varicocele grading ≤ 1. There was no postoperative testicular atrophy, hydrocele and epididymo-orchitis. Scrotal antegrade sclerotherapy using STS foam is a safe and effective treatment for adolescent varicoceles. Anatomical variations on venous drainage in varicoceles are common.
... Open the bottle by pushing down on the cap and turning the cap at the same time. Push the plunger of ... not mix with any other liquids. Replace the cap on the bottle and close tightly. Remove the ...
La Padula, Simone; Hersant, Barbara; Noel, Warren; Niddam, Jeremy; Hermeziu, Oana; Bouhassira, Jonathan; Bosc, Romain; Meningaud, Jean Paul
2016-09-01
Venous congestion is a common cause of DIEP flap failure. When identified intraoperatively, an additional venous anastomosis can improve the venous outflow and prevent flap failure. The aim of this study was to assess if the retrograde limb of the internal mammary vein (IMV) could be considered a good recipient vessel to be used when persistent flap congestion is present, and a second venous anastomosis is required. A retrospective study was conducted in 74 patients who had undergone DIEP flap breast reconstruction. Patients were classified into two groups: SVA (single venous anastomosis) and DVA (dual venous anastomosis). In the SVA group (n = 38), the IMV antegrade limb was used for venous drainage. A single DIEV (Deep Inferior Epigastric Vein) was anastomosed to the superior arm of the IMV. In the DVA group (n = 36), both the antegrade (superior) and retrograde (inferior) stumps of the IMV were used, connecting the larger DIEV to the antegrade IMV and the other DIEV or the SIEV (Superficial Inferior Epigastric Vein) to the IMV retrograde limb. No venous congestion or flap loss was observed when two venous anastomoses were performed using both the IMV antegrade and retrograde limbs (P = 0.3271). In the DVA group, no major complication occurred (P = 0.0453). Operative explorations were significantly reduced in the DVA group (P = 0.0242). These findings suggest that when an additional venous outflow is required, the use of the IMV retrograde limb may help to avoid flap venous congestion. © 2016 Wiley Periodicals, Inc. Microsurgery 36:447-452, 2016. © 2016 Wiley Periodicals, Inc.
Manual lymphatic drainage in chronic venous disease: a duplex ultrasound study.
Dos Santos Crisóstomo, Rute Sofia; Candeias, Miguel Sandu; Ribeiro, Ana Margarida Martins; da Luz Belo Martins, Catarina; Armada-da-Silva, Paulo As
2014-12-01
To compare the effect of call-up and reabsorption maneuvers of manual lymphatic drainage on blood flow in femoral vein and great saphenous vein in patients with chronic venous disease and healthy controls. Forty-one subjects participated in this study (mean age: 42.68(15.23)), 23 with chronic venous disease (chronic venous disease group) with clinical classification C1-5 of clinical-etiological-anatomical-pathological (CEAP) and 18 healthy subjects (control group). Call-up and reabsorption maneuvers were randomly applied in the medial aspect of the thigh. The cross-sectional areas, as well as the peak and the mean blood flow velocity at femoral vein and great saphenous vein, were assessed by Duplex ultrasound at the baseline and during maneuvers. The venous flow volume changes were calculated. The venous flow volume in femoral vein and great saphenous vein increased during both manual lymphatic drainage maneuvers and in both groups (P < 0.05). The two maneuvers had a similar effect on femoral vein and great saphenous vein hemodynamics, and in both the chronic venous disease and control groups. As a result of the call-up maneuver, the flow volume augmentations, as a result of call-up maneuver, decreased with the severity of chronic venous disease in those patients measured by the clinical classification of CEAP (r = -0.64; P = 0.03). Manual lymphatic drainage increases the venous blood flow in the lower extremity with a magnitude that is independent from the specific maneuver employed or the presence of chronic venous disease. Therefore, manual lymphatic drainage may be an alternative strategy for the treatment and prevention of venous stasis complications in chronic venous disease. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Central venous catheter-related thrombosis in senile male patients: New risk factors and predictors.
Liu, Gao; Fu, Zhi-Qing; Zhu, Ping; Li, Shi-Jun
2015-06-01
Central venous catheterization (CVC)-related venous thrombosis is a common but serious clinical complication, thus prevention and treatment on this problem should be extensively investigated. In this research, we aimed to investigate the incidence rate of CVC-related venous thrombosis in senile patients and give a further discussion on the related risk factors and predictors. A total of 324 hospitalized senile male patients subjected to CVC were selected. Retrospective investigation and analysis were conducted on age, underlying diseases, clinical medications, catheterization position and side, catheter retention time, and incidence of CVC-related venous thrombosis complications. Basic laboratory test results during catheterization and thrombogenesis were also collected and analyzed. Among the 324 patients, 20 cases (6.17%) of CVC-related venous thrombosis were diagnoseds. The incidence rate of CVC-related venous thrombosis in subclavian vein catheterization was significantly lower than that in femoral vein catheterization (P<0.01) and that in internal jugular vein catheterization (P<0.05). No statistically significant difference was found between femoral vein catheterization and internal jugular vein catheterization (P<0.05). Previous venous thrombosis history (P<0.01), high lactate dehydrogenase level (P<0.01), low high-density lipoprotein (HDL) level (P<0.05), and low albumin level (P<0.05) were found as risk factors or predictors of CVC-related venous thrombosis in senile male patients. Subclavian vein catheterization was the most appropriate choice among senile patients to decrease the incidence of CVC-related venous thrombosis. Previous venous thrombosis history, high lactate dehydrogenase level, low HDL level, and low albumin level were important risk factors in predicting CVC-related venous thrombosis.
Woller, Scott C; Stevens, Scott M; Evans, R Scott; Wray, Daniel G; Christensen, John C; Aston, Valerie T; Wayne, Matthew H; Lloyd, James F; Wilson, Emily L; Elliott, C Gregory
2016-10-01
Venous thromboembolism chemoprophylaxis remains underutilized in hospitalized medical patients at high risk for venous thromboembolism. We assessed the effect of a health care quality-improvement initiative comprised of a targeted electronic alert, comparative practitioner metrics, and practitioner-specific continuing medical education on the rate of appropriate venous thromboembolism chemoprophylaxis provided to medical inpatients at high risk for venous thromboembolism. We performed a multicenter prospective observational cohort study in an urban Utah hospital system. All medical patients admitted to 1 of 2 participating hospitals from April 1, 2010 to December 31, 2012 were eligible. Patients were members of the "control" (April 1, 2010 to December 31, 2010), "intervention" (January 1, 2011 to December 31, 2011), or "subsequent year" (January 1, 2012 to December 31, 2012) group. The primary outcome was the rate of appropriate chemoprophylaxis among patients at high risk for venous thromboembolism. Secondary outcomes included rates of symptomatic venous thromboembolism, major bleeding, all-cause mortality, heparin-induced thrombocytopenia, physician satisfaction, and alert fatigue. The rate of appropriate chemoprophylaxis among patients at high risk for venous thromboembolism increased (66.1% control period vs 81.0% intervention period vs 88.1% subsequent year; P <.001 for each comparison). A significant reduction of 90-day symptomatic venous thromboembolism accompanied the quality initiative (9.3% control period, 9.7% intervention period, 6.7% subsequent year; P = .009); 30-day venous thromboembolism rates also significantly decreased. A multifaceted intervention was associated with increased appropriate venous thromboembolism chemoprophylaxis among medical inpatients at high risk for venous thromboembolism and reduced symptomatic venous thromboembolism. The effect of the intervention was sustained. Copyright © 2016 Elsevier Inc. All rights reserved.
Ambulatory Status Protects against Venous Thromboembolism in Acute Mild Ischemic Stroke Patients.
Sisante, Jason-Flor V; Abraham, Michael G; Phadnis, Milind A; Billinger, Sandra A; Mittal, Manoj K
2016-10-01
Ischemic stroke patients are at high risk (up to 18%) for venous thromboembolism. We conducted a retrospective cross-sectional study to understand the predictors of acute postmild ischemic stroke patient's ambulatory status and its relationship with venous thromboembolism, hospital length of stay, and in-hospital mortality. We identified 522 patients between February 2006 and May 2014 and collected data about patient demographics, admission NIHSS (National Institutes of Health Stroke Scale), venous thromboembolism prophylaxis, ambulatory status, diagnosis of venous thromboembolism, and hospital outcomes (length of stay, mortality). Chi-square test, t-test and Wilcoxon rank-sum test, and binary logistic regression were used for statistical analysis as appropriate. A total of 61 (11.7%), 48 (9.2%), and 23 (4.4%) mild ischemic stroke patients developed venous thromboembolism, deep venous thrombosis, and pulmonary embolism, respectively. During hospitalization, 281 (53.8%) patients were ambulatory. Independent predictors of in-hospital ambulation were being married (OR 1.64, 95% CI 1.10-2.49), being nonreligious (OR 2.19, 95% CI 1.34-3.62), admission NIHSS (per unit decrease in NIHSS; OR 1.62, 95% CI 1.39-1.91), and nonuse of mechanical venous thromboembolism prophylaxis (OR 1.62, 95% CI 1.02-2.61). After adjusting for confounders, ambulatory patients had lower rates of venous thromboembolism (OR .47, 95% CI .25-.89), deep venous thrombosis (OR .36, 95% CI .17-.73), prolonged length of hospital stay (OR .24, 95% CI .16-.37), and mortality (OR .43, 95% CI .21-.84). Our findings suggest that for hospitalized acute mild ischemic stroke patients, ambulatory status is an independent predictor of venous thromboembolism (specifically deep venous thrombosis), hospital length of stay, and in-hospital mortality. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Gender-related Changes in Dorsal Hand and Foot Vein Function Following 60 Days of Head Down Bed Rest
NASA Technical Reports Server (NTRS)
Westby, Christian M.; Phillips, Tiffany; Stenger, Michael B.; Platts, Steven H.
2009-01-01
It is well known that female astronauts are more likely to experience post-flight orthostatic hypotension and presyncope compared to male astronauts. It has been suggested that the disproportionally higher incidence of presyncope (83% of female vs. 20% male crewmembers) may be due to sex-related differences in vascular function between the upper and lower limbs. However, much of this evidence is specific to changes in resistance vessels. Given that more than 70% of the circulating blood volume resides in compliance vessels, it is conceivable that even small changes in venous function may contribute to post-flight orthostatic hypotension. In spite of this, little is currently known regarding the influence of microgravity exposure on venous function between males and females. PURPOSE: To determine the influence of 60 days of HDBR on dorsal foot and hand vein function between healthy males (M) and females (F). METHODS: Using 2-D ultrasound, dorsal hand and foot vein diameter responses to intravenous infusions phenylephrine (PE), acetylcholine (ACh), and nitroglycerine (NTG) were determined in 26 adults; 10 females (age:37 +/- 2 yr ) and 16 males (age:34 +/- 2 yr ). Changes in venous function were calculated as the difference between diameter at baseline and following each venoactive drug. Differences in venous function between limb and sexes across HDBR were determined using mixed-effects linear regression. RESULTS: In response to 60 days of HDBR, the change in venousconstrictor response to PE in the dorsal hand veins was not significantly different between M and F. Interestingly, the change in constrictor response in the dorsal foot veins (compared to pre HDBR) was approximately 30% greater in the F, whereas the constrictor response was approximately 45% less in the M (p=0.026). HDBR had no influence on the change in dilator response to ACh, or NTG between M and F and between vascular beds. CONCLUSION: These results demonstrate that 60 days of HDBR contributes to sex-related differences in venous function. Importantly, the changes are specific to dorsal foot veins and do not appear to be related to changes in endothelial or smooth muscle function. Previous data from our laboratory indicate that females have an impaired sympathetic response following HDBR. However, the results from the current investigation imply that F maintain the ability to respond to sympathetic stimulation but may not be able to adequately activate a proper response following HDBR.
Detection of deep venous thrombophlebitis by gallium 67 scintigraphy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, J.H.
1981-07-01
Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.
Detection of deep venous thrombophlebitis by Gallium 67 scintigraphy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, J.H.
1981-07-01
Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.
Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.
Ozmen, Evrim; Algin, Oktay
2016-07-12
Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.
Pichaiwong, Warangkana; Leelahavanichkul, Asada; Eiam-ong, Somchai
2006-08-01
To compare the clearance performances and biocompatibility between the modified cellulose membrane and the standard synthetic membrane in continuous renal replacement therapy (CRRT). Seventeen patients with acute renal failure (ARF) were treated with separated continuous veno venous hemofiltration (CVVH) system conducted with the pre-dilution mode. The modified cellulose used was a Sureflux150E (cellulose triacetate) and the standard synthetic membranes used was an AV-400. Blood and replacement flow rate were kept at 100 and 20 mL/min, respectively. Ultrafiltraion rate was 1,200 mL/hr. Samplings of blood and ultrafiltrate were collected at baseline, 2, 8, 16, and 24 hr. Patients in both methods could similarly tolerate CRRT with only minor complications. Sureflux 150E and AV-400 provided comparable values of sieving coefficients and clearances of small solutes. The albumin loss in ultrafiltrate by Sureflux 150E was greater than AV-400. The values of life span and biocompatability of both hemofilters were not different. Because of the excellent efficacy and the much cheaper cost, the modified cellulose membrane could be an appropriate alternative to standard synthetic membrane in CRRT.
Nursing essential principles: continuous renal replacement therapy.
Richardson, Annette; Whatmore, Jayne
2015-01-01
This article aims to guide critical care nurses with the care and management of patients on continuous renal replacement therapy (CRRT). CRRT, a highly specialized therapy involving complex nursing care, is used widely in the intensive care unit to treat patients with acute kidney injury. A literature search was conducted using CINAHL, Medline from PubMed and BNI using the search terms CRRT or continuous veno-venous haemofiltration and nursing or nurses from 2000 onwards and limited to the English language. The appraised evidence and expert opinion is used in this article. Four essential nursing principles for CRRT are reviewed (1) the importance of continuous assessment of the indications to influence the appropriate mode; (2) ensuring good vascular access; (3) the avoidance of unnecessary interruptions and (4) the prevention of complications. The identified four essential nursing principles provide guidance on this complex aspects of nursing practice. Specific nursing research to guide the care and management of this therapy is limited so should be explored in the future. Critical care nurses caring for and managing patients on CRRT require an understanding of how to deliver safe CRRT. © 2014 British Association of Critical Care Nurses.
Current indications for left thoracotomy in coronary revascularization and valvular procedures.
Pratt, J W; Williams, T E; Michler, R E; Brown, D A
2000-10-01
Left thoracotomy is infrequently used for cardiac procedures, but its application in reoperative and minimally invasive coronary revascularization and in valvular procedures has been reported recently. Three case reports and a review of the current literature illustrate the unique benefits of this approach for myocardial revascularization and valve replacement. Reoperative coronary revascularization of the left anterior descending and circumflex coronary arteries was performed off-pump via a left posterolateral thoracotomy. For the second case, this approach was used for coronary artery bypass grafting of the right coronary and left anterior descending arteries with femoral-femoral cardiopulmonary bypass in a patient with congestive heart failure and coronary artery disease who also required closure of a patent ductus arteriosus. In the third case, mitral valve replacement using femoral venous and aortic cannulation for cardiopulmonary bypass was performed via a left thoracotomy to avoid a retrosternal gastric conduit in a patient with severe mitral stenosis and congestive heart failure. All patients returned to normal activity and are asymptomatic. These case reports and a comprehensive review of the literature demonstrate the utility of left thoracotomy as an alternative approach to standard median sternotomy in selected cases of revascularization and valvular procedures.
Wu, Olivia; Robertson, Lindsay; Twaddle, Sara; Lowe, Gordon; Clark, Peter; Walker, Isobel; Brenkel, Ivan; Greaves, Mike; Langhorne, Peter; Regan, Lesley; Greer, Ian
2005-10-01
Laboratory testing for the identification of heritable thrombophilia in high-risk patient groups have become common practice; however, indiscriminate testing of all patients is unjustified. The objective of this study was to evaluate the cost-effectiveness of universal and selective history-based thrombophilia screening relative to no screening, from the perspective of the UK National Health Service, in women prior to prescribing combined oral contraceptives and hormone replacement therapy, women during pregnancy and patients prior to major orthopaedic surgery. A decision analysis model was developed, and data from meta-analysis, the literature and two Delphi studies were incorporated in the model. Incremental cost-effectiveness ratios (ICERs) for screening compared with no screening was calculated for each patient group. Of all the patient groups evaluated, universal screening of women prior to prescribing hormone replacement therapy was the most cost-effective (ICER 6824 pounds). In contrast, universal screening of women prior to prescribing combined oral contraceptives was the least cost-effective strategy (ICER 202,402 pounds). Selective thrombophilia screening based on previous personal and/or family history of venous thromboembolism was more cost-effective than universal screening in all the patient groups evaluated.
Koo, Bon-Min; Kim, Jang-Ho Jay; Kim, Tae-Kyun; Kim, Byung-Yun
2015-01-01
In this study, the amount of cement used in a concrete mix is minimized to reduce the toxic effects on users by adjusting the concrete mixture contents. The reduction of cement is achieved by using various admixtures (ground granulated blast-furnace slag, flyash, ordinary Portland cement, and activated Hwangtoh powder). To apply the mix to construction, material property tests such as compressive strength, slump, and pH are performed. Preliminary experimental results showed that the Hwangtoh concrete could be used as a healthy construction material. Also, the health issues and effects of Hwangtoh mortar are quantitatively evaluated through an animal clinical test. Mice are placed in Hwangtoh mortar and cement mortar cages to record their activity. For the test, five cages are made with Hwangtoh and ordinary Portland cement mortar floors, using Hwangtoh powder replacement ratios of 20%, 40%, 60%, and 80% of the normal cement mortar mixing ratio, and two cages are made with Hwangtoh mortar living quarters. The activity parameter measurements included weight, food intake, water intake, residential space selection, breeding activity, and aggression. The study results can be used to evaluate the benefits of using Hwangtoh as a cement replacing admixture for lifestyle, health and sustainability. PMID:28793563
Koo, Bon-Min; Kim, Jang-Ho Jay; Kim, Tae-Kyun; Kim, Byung-Yun
2015-09-17
In this study, the amount of cement used in a concrete mix is minimized to reduce the toxic effects on users by adjusting the concrete mixture contents. The reduction of cement is achieved by using various admixtures (ground granulated blast-furnace slag, flyash, ordinary Portland cement, and activated Hwangtoh powder). To apply the mix to construction, material property tests such as compressive strength, slump, and pH are performed. Preliminary experimental results showed that the Hwangtoh concrete could be used as a healthy construction material. Also, the health issues and effects of Hwangtoh mortar are quantitatively evaluated through an animal clinical test. Mice are placed in Hwangtoh mortar and cement mortar cages to record their activity. For the test, five cages are made with Hwangtoh and ordinary Portland cement mortar floors, using Hwangtoh powder replacement ratios of 20%, 40%, 60%, and 80% of the normal cement mortar mixing ratio, and two cages are made with Hwangtoh mortar living quarters. The activity parameter measurements included weight, food intake, water intake, residential space selection, breeding activity, and aggression. The study results can be used to evaluate the benefits of using Hwangtoh as a cement replacing admixture for lifestyle, health and sustainability.
Ma, Junhao; Li, Xinxi; Wang, Yang; Yang, Zhenwei; Luo, Jun
2017-01-01
Anticoagulant therapy is commonly used for the prevention and treatment of patients with deep venous thrombus. Evidence has shown that rivaroxaban is a potential oral anticoagulant drug for the acute treatment of venous thromboembolism. However, the rivaroxaban-mediated molecular mechanism involved in the progression of deep venous thrombosis has not been investigated. In the present study, we investigated the efficacy of rivaroxaban and the underlying signaling pathways in the prevention and treatment of rats with deep venous thrombosis. A rat model with deep vein thrombus formation was established and received treatment with rivaroxaban or PBS as control. The thrombin-activatable fibrinolysis inhibitor (TAFI) and plasminogen activator inhibitor-1 (PAI-1) were analyzed both in vitro and in vivo. The progression of thrombosis and stroke was evaluated after treatment with rivaroxaban or PBS. Nuclear factor-κB (NF-κB) signaling pathway in venous endothelial cells and in the rat model of deep venous thrombus was assessed. The therapeutic effects of rivaroxaban were evaluated as determined by changes in deep venous thrombosis in the rat model. Our results showed that rivaroxaban markedly inhibited TAFI and PAI-1 expression levels, neutrophils, tissue factor, neutrophil extracellular traps (NETs), myeloperoxidase and macrophages in venous endothelial cells and in the rat model of deep venous thrombus. Expression levels of ADP, PAIs, von Willebrand factor (vWF) and thromboxane were downregulated in vein endothelial cells and in serum from the experimental rats. Importantly, the incidences of inferior vena cava filter thrombus were protected by rivaroxaban during heparin-induced thrombolysis deep venous thrombosis in the rat model. We observed that activity of the NF-κB signaling pathway was inhibited by rivaroxaban in vein endothelial cells both in vitro and in vivo. Notably, immunohistology indicated that rivaroxaban attenuated deep venous thrombosis and the accumulation of inflammatory factors in the lesions in venous thrombus. Matrix metalloproteinase (MMP) expression and activity were downregulated in rivaroxaban-treated rats with deep venous thrombus. Rivaroxaban inhibited the elasticity of the extracellular matrix and collagen-elastin fibers. On the whole, these results indicate that rivaroxaban attenuates deep venous thrombus through MMP-9-mediated NF-κB signaling pathway. PMID:29039441
Ma, Junhao; Li, Xinxi; Wang, Yang; Yang, Zhenwei; Luo, Jun
2017-12-01
Anticoagulant therapy is commonly used for the prevention and treatment of patients with deep venous thrombus. Evidence has shown that rivaroxaban is a potential oral anticoagulant drug for the acute treatment of venous thromboembolism. However, the rivaroxaban-mediated molecular mechanism involved in the progression of deep venous thrombosis has not been investigated. In the present study, we investigated the efficacy of rivaroxaban and the underlying signaling pathways in the prevention and treatment of rats with deep venous thrombosis. A rat model with deep vein thrombus formation was established and received treatment with rivaroxaban or PBS as control. The thrombin-activatable fibrinolysis inhibitor (TAFI) and plasminogen activator inhibitor-1 (PAI-1) were analyzed both in vitro and in vivo. The progression of thrombosis and stroke was evaluated after treatment with rivaroxaban or PBS. Nuclear factor-κB (NF-κB) signaling pathway in venous endothelial cells and in the rat model of deep venous thrombus was assessed. The therapeutic effects of rivaroxaban were evaluated as determined by changes in deep venous thrombosis in the rat model. Our results showed that rivaroxaban markedly inhibited TAFI and PAI-1 expression levels, neutrophils, tissue factor, neutrophil extracellular traps (NETs), myeloperoxidase and macrophages in venous endothelial cells and in the rat model of deep venous thrombus. Expression levels of ADP, PAIs, von Willebrand factor (vWF) and thromboxane were downregulated in vein endothelial cells and in serum from the experimental rats. Importantly, the incidences of inferior vena cava filter thrombus were protected by rivaroxaban during heparin-induced thrombolysis deep venous thrombosis in the rat model. We observed that activity of the NF-κB signaling pathway was inhibited by rivaroxaban in vein endothelial cells both in vitro and in vivo. Notably, immunohistology indicated that rivaroxaban attenuated deep venous thrombosis and the accumulation of inflammatory factors in the lesions in venous thrombus. Matrix metalloproteinase (MMP) expression and activity were downregulated in rivaroxaban-treated rats with deep venous thrombus. Rivaroxaban inhibited the elasticity of the extracellular matrix and collagen-elastin fibers. On the whole, these results indicate that rivaroxaban attenuates deep venous thrombus through MMP-9-mediated NF-κB signaling pathway.
14 CFR 151.39 - Project eligibility.
Code of Federal Regulations, 2010 CFR
2010-01-01
... located; and (ii) Adequate replacement housing that is open to all persons, regardless of race, color...) Bituminous resurfacing of pavements with a minimum of 100 pounds of plant-mixed material for each square yard...
14 CFR 151.39 - Project eligibility.
Code of Federal Regulations, 2011 CFR
2011-01-01
... located; and (ii) Adequate replacement housing that is open to all persons, regardless of race, color...) Bituminous resurfacing of pavements with a minimum of 100 pounds of plant-mixed material for each square yard...
Non-Carcinogenic Replacements for PBNA Antioxidant in PBXN-105 and PBXN- 106 Explosives
1980-01-01
U~3 *y.4~;NWSY TR 801 NON-CARCINOGENIC REPLACEMENTS O ’ ~FOR PBNA ANTIOXIDANT IN PBXN -10.5 AND PBXN - 106 EXPLOSIVESo...... ............. JANUARY 1980... PBXN - 106 Explosive Plastic-Bonded Explosive % ABSSRACT (Continue on reverse olde It neceeeoey end Identify by block number) ’ Explosive mixes of PBXN -105...and PBXN - 106 were prepared using Cyanox 2246 and CAO-14 antioxidants in lieu of phenyl-beta-naphthylamine (PBNA). Specification tests, as well as
Laparoscopic correction of congenital portosystemic shunt in children.
Kimura, Takuya; Soh, Hideki; Hasegawa, Toshimichi; Sasaki, Takashi; Kuroda, Seika; Yuri, Etani; Tomoda, Kaname; Fukuzawa, Masahiro
2004-10-01
Congenital portosystemic shunt is a rare clinical entity that may progress to jaundice, severe encephalopathy, and pulmonary hypertension and require surgical correction or coil embolization. We present a novel approach to the management of children with congenital portosystemic shunt by means of a minimally invasive surgical technique. Congenital portosystemic shunts were identified between the superior mesenteric vein and inferior vena cava in case 1 and between the splenic vein and left renal vein in case 2. Both of them were successfully ligated by laparoscopic approach, and catheters were subsequently replaced to monitor portal venous pressure. The patients tolerated the procedure well, and short-term results were excellent. Laparoscopic ligation of congenital portosystemic shunt is technically feasible and less invasive to the management of patients with congenital portosystemic shunts, preventing late onset, life-threatening complications.
Nakagawa, Mitsuhide; Suzuki, Kazuyuki; Takahashi, Fumito; Kamikatano, Kazuhiro; Koiwa, Masateru; Taguchi, Kiyoshi
2009-06-01
The aims of this study were to confirm whether commercial acetated Ringer's solution, which contains 28 mM of sodium acetate, is superior to commercial lactated Ringer's solution in alkalizing effects in calves with experimentally induced metabolic acidosis. Twenty calves with experimentally induced mild acidosis were intravenously administered isotonic saline, DL-lactated, L-lactated or acetated Ringer's solution at a dose of 80 ml/kg body weight (BW). The acetated Ringer's solution induced a significantly greater increase in venous HCO(3)(-) and base excess concentrations than the other fluids during the early phases of extracellular fluid replacement in mild metabolic acidosis. Therefore, the alkalizing effect of commercial acetated Ringer's solution is superior to commercial DL- and L-lactated Ringer's solution in treatment of mild metabolic acidosis in calves.
Non-Vitamin K Oral Anticoagulants (NOACs) A Review of Clinical Management and Laboratory Issues.
Blann, Andrew
2016-01-01
The non-vitamin K oral anticoagulants (NOACs) are set to replace vitamin K antagonists (principally warfarin), unfractionated heparin and low molecular weight heparin as the leading antithrombotic prophylaxis in several medical and surgical settings. As a group, NOACs have a better safety profile and at least an equivalent (and sometimes superior) efficacy profile than their comparator. The objective of this review is to provide the practitioner with a comprehensive, balanced and contemporary view of these drugs and their applications. More specifically, it focuses on the evidence base for their licences, use in clinical practice (such as in renal dysfunction, orthopaedic surgery, atrial fibrillation, and venous thromboembolism, and the effects of co-medications), responses to actual or perceived haemorrhage, and the role of the laboratory.
Drug Interactions of Direct-Acting Oral Anticoagulants.
Fitzgerald, John Leonard; Howes, Laurence Guy
2016-09-01
In recent years, new direct-acting oral anticoagulants (DOACs) have been introduced into clinical practice that specifically inhibit either factor Ia or Xa. These drugs have, to a large extent, replaced warfarin for the treatment of venous thrombosis, pulmonary embolism, and non-valvular atrial fibrillation. They have potential advantages over warfarin in providing more stable anticoagulation and the lack of a need for regular venesection to monitor activity. They also have the promise of less drug and food interactions. All of these drugs are substrates for the permeability glycoprotein (P-gp) excretion system, and several are metabolised, in part, by cytochrome P450 (CYP) 3A4. This current article assesses the interactions that do or may occur with the DOACs, particularly with respect to the P-gp and CYP3A4 systems.
Percutaneous transfemoral repositioning of malpositioned central venous catheters.
Hartnell, G G; Roizental, M
1995-04-01
Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.
Totally normothermic aortic arch replacement without circulatory arrest.
Touati, Gilles D; Marticho, Paul; Farag, Moataz; Carmi, Doron; Szymanski, Catherine; Barry, Misbaou; Trojette, Faouzi; Caus, Thierry
2007-08-01
Various techniques have been proposed for cerebral protection during the surgical treatment of complex aortic disease. The authors propose a revisited strategy of normothermic replacement of the aortic arch to avoid limitations and complications of profound hypothermic circulatory arrest. From April 2000 to May 2006, 19 patients with an aneurysm of the aortic arch and 10 patients with an acute (7) or a chronic (3) aortic dissection underwent a totally normothermic, complete replacement of the aortic arch using three pumps: One pump ensured antegrade cerebral perfusion, at a flow rate adapted to obtain a pressure of 70 mmHg in the right radial artery, and required a selective cannulation of the supra-aortic vessels. A second pump ensured body perfusion at a flow rate adapted to obtain a pressure of 55 mmHg in the left femoral artery and was situated between the right femoral artery and the right atrium. A special balloon aortic occlusion catheter was placed in the descending thoracic aorta. A third pump ensured intermittent normothermic myocardial perfusion via the coronary venous sinus. The arch reconstruction was performed with no time limit. There were two operative, in-hospital (6.8%) mortalities. All others patients were rapidly extubated, except one, with no neurological sequelae, and postoperative course was uneventful, without coagulopathy or hepato-renal impairment. In the light of these results, a normothermic procedure is possible for arch surgery and may ensure a more physiological autoregulation of cerebral blood flow while maintaining body perfusion without high vascular resistances.
Interhospital differences and case-mix in a nationwide prevalence survey.
Kanerva, M; Ollgren, J; Lyytikäinen, O
2010-10-01
A prevalence survey is a time-saving and useful tool for obtaining an overview of healthcare-associated infection (HCAI) either in a single hospital or nationally. Direct comparison of prevalence rates is difficult. We evaluated the impact of case-mix adjustment on hospital-specific prevalences. All five tertiary care, all 15 secondary care and 10 (25% of 40) other acute care hospitals took part in the first national prevalence survey in Finland in 2005. US Centers for Disease Control and Prevention criteria served to define HCAI. The information collected included demographic characteristics, severity of the underlying disease, use of catheters and a respirator, and previous surgery. Patients with HCAI related to another hospital were excluded. Case-mix-adjusted HCAI prevalences were calculated by using a multivariate logistic regression model for HCAI risk and an indirect standardisation method. Altogether, 587 (7.2%) of 8118 adult patients had at least one infection; hospital-specific prevalences ranged between 1.9% and 12.6%. Risk factors for HCAI that were previously known or identified by univariate analysis (age, male gender, intensive care, high Charlson comorbidity and McCabe indices, respirator, central venous or urinary catheters, and surgery during stay) were included in the multivariate analysis for standardisation. Case-mix-adjusted prevalences varied between 2.6% and 17.0%, and ranked the hospitals differently from the observed rates. In 11 (38%) hospitals, the observed prevalence rank was lower than predicted by the case-mix-adjusted figure. Case-mix should be taken into consideration in the interhospital comparison of prevalence rates. Copyright 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Benchmarking antibiotic use in Finnish acute care hospitals using patient case-mix adjustment.
Kanerva, Mari; Ollgren, Jukka; Lyytikäinen, Outi
2011-11-01
It is difficult to draw conclusions about the prudence of antibiotic use in different hospitals by directly comparing usage figures. We present a patient case-mix adjustment model of antibiotic use to rank hospitals while taking patient characteristics into account. Data on antibiotic use were collected during the national healthcare-associated infection (HAI) prevalence survey in 2005 in Finland in all 5 tertiary care, all 15 secondary care and 10 (25% of 40) other acute care hospitals. The use of antibiotics was measured using use-days/100 patient-days during a 7day period and the prevalence of patients receiving at least two antimicrobials during the study day. Case-mix-adjusted antibiotic use was calculated by using multivariate models and an indirect standardization method. Parameters in the model included age, sex, severity of underlying diseases, intensive care, haematology, preceding surgery, respirator, central venous and urinary catheters, community-associated infection, HAI and contact isolation due to methicillin-resistant Staphylococcus aureus. The ranking order changed one position in 12 (40%) hospitals and more than two positions in 13 (43%) hospitals when the case-mix-adjusted figures were compared with those observed. In 24 hospitals (80%), the antibiotic use density observed was lower than expected by the case-mix-adjusted use density. The patient case-mix adjustment of antibiotic use ranked the hospitals differently from the ranking according to observed use, and may be a useful tool for benchmarking hospital antibiotic use. However, the best set of easily and widely available parameters that would describe both patient material and hospital activities remains to be determined.
Right atrial pressure: determinant or result of change in venous return?
Bendjelid, Karim
2005-11-01
According to the concept of Guyton, cardiac output is largely controlled by venous return, which is determined by the difference between mean systemic venous pressure and right atrial pressure. In the analysis of the venous return curve, other authors have suggested that right atrial pressure is the dependent variable and venous return is the independent variable (right atrial pressure decreased because cardiac output increased). The present report analyzes this historical debate, which has already lasted > 50 years.
Role of interventional radiologists in the management of lower extremity venous insufficiency.
Hardman, Rulon L; Rochon, Paul J
2013-12-01
Lower extremity venous insufficiency affects over half of all women. Interventional radiologists should be aware of the clinical evaluation of women with venous insufficiency and classification of disease. Endovascular therapies available for treatment of lower extremity venous insufficiency include: endovenous laser ablation, radiofrequency endovascular ablation, and sclerotherapy. The interventional radiologist should be versed on which therapy to select in each clinical presentation and the procedural techniques. The authors review the role of the interventional radiologist in managing this lower extremity venous disorder.
... thrombophlebitis. Alternative Names Phlebitis; Deep vein thrombosis - thrombophlebitis Images Deep venous thrombosis, iliofemoral Venous blood clot References Ginsberg JS. Peripheral venous disease. In: Goldman L, Schafer AI, ...
Femoral vein injury managed by in situ saphenous vein bypass : a case report.
Coppin, Th; Kuhnle, M
2014-01-01
Injured veins of the lower limbs may cause massive haemorrhage requiring early control. Operative management of injured veins remains a controversial topic and reconstruction or ligation depends on venous and adjacent tissue damage. Nevertheless, venous reconstruction seems to reduce the complications of venous ligation. The case of a 33 year old women with a venous wound to the right groin is presented. Surgical management consisted of controlling the bleeding and venous revascularisation with an in situ saphenous vein bypass to substitute the injured femoral vein. The patient had an uneventful postoperative period without any complications. The case demonstrates this method of vascular venous repair is the preferable one. Copyright© Acta Chirurgica Belgica.
Baser, Onur; Supina, Dylan; Sengupta, Nishan; Wang, Li; Kwong, Louis
2011-02-01
Venous thromboembolism (VTE) occurs most often during hospitalization for major surgery or trauma but may also occur up to several months after surgery. Since the potential for VTE exists in a range of clinical settings, an assessment of its impact on overall outcomes and costs to the patient and to the healthcare system is warranted. To evaluate the effects of VTE (deep vein thrombosis, pulmonary embolism, or both) occurring within the first 30 days of hospital discharge for total hip replacement (THR) or total knee replacement (TKR) surgery on inpatient costs, mortality, rehospitalization, and major bleeding within 1 year after initial hospitalization for THR or TKR surgery. The Medicare Provider Analysis and Review (MEDPAR) file for calendar years 2005-2007 provided hospital discharge abstracts for the fee-for-service, acute-care hospitalizations of all Medicare recipients. All patients included in the analysis underwent THR (n = 51,108) or TKR (n = 115,627). VTE events were diagnosed within the first 30 days and within 1 year post discharge. Propensity score matching was used to control for differences in baseline characteristics in patients with and without VTE events. Total cost was measured as Medicare cost plus beneficiary out-of-pocket cost. VTE occurred in 0.74% of patients undergoing THR. For patients with VTE versus no VTE, mortality was higher (2.9% vs 0.4%, P < 0.001) and rehospitalization within 1 year was more frequent (51.9% vs 22.4%, P < 0.001), as were complications such as bleeding (11.2% vs 2.7%, P < 0.001). Risk-adjusted Medicare cost and total healthcare cost, including beneficiary cost share in 1 year, were significantly higher for VTE patients versus patients with no VTE ($18,929 vs $3763, P < 0.001). VTE occurred in 0.70% of patients undergoing TKR. For patients with VTE versus no VTE, mortality was higher (2.5% vs 0.15%, P < 0.001), and rehospitalization within 1 year was more frequent (48.7% vs 20.7%, P < 0.001), as were complications such as bleeding (13.7% vs 2.1%, P < 0.001). For TKR surgery, risk-adjusted total healthcare cost, including beneficiary cost share in 1 year, was significantly different for VTE versus no VTE ($17,996 vs $4358, P < 0.001). Study limitations include a reliance on ICD-9-CM codes, which could be inaccurate, and the inability (1) to control for unmeasured confounders, such as surgeons' skills; (2) to include outpatient medical care costs; and (3) to ensure that all patients were enrolled continuously throughout the study period. VTE after THR or TKR is associated with higher mortality, rehospitalization, and bleeding within 1 year, compared with no VTE. Risk-adjusted total, Medicare, and beneficiary healthcare costs were significantly higher for both THR and TKR patients with VTE (P < 0.001).
Core content for training in venous and lymphatic medicine.
Zimmet, Steven E; Min, Robert J; Comerota, Anthony J; Meissner, Mark H; Carman, Teresa L; Rathbun, Suman W; Jaff, Michael R; Wakefield, Thomas W; Feied, Craig F
2014-10-01
The major venous societies in the United States share a common mission to improve the standards of medical practitioners, the educational goals for teaching and training programs in venous disease, and the quality of patient care related to the treatment of venous disorders. With these important goals in mind, a task force made up of experts from the specialties of dermatology, interventional radiology, phlebology, vascular medicine, and vascular surgery was formed to develop a consensus document describing the Core Content for venous and lymphatic medicine and to develop a core educational content outline for training. This outline describes the areas of knowledge considered essential for practice in the field, which encompasses the study, diagnosis, and treatment of patients with acute and chronic venous and lymphatic disorders. The American Venous Forum and the American College of Phlebology have endorsed the Core Content. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Duplex investigations in children: Are clinical signs in children with venous disorders relevant?
Birgitte Maessen-Visch, M; Smeets, L; van Vleuten, C
2015-12-01
Ultra sound colored duplex sonography is the preferred method in diagnosing chronic venous disease. Data in children on incidence, indications, and results are lacking. From the total of 9180 duplex investigations performed in our hospital from 2009 to 2012, data on indication and results of the investigation as well as patient characteristics were evaluated retrospectively for the proportion of pediatric patients. Duplex investigations were performed 49 times in 38 children (6-18 years), with an average of 1.3 times (1-6 times) per child. Forty percent showed abnormalities: 17 times deep venous thrombosis was suspected; deep venous thrombosis was objectified in 18%. In the 21 investigations performed for varicosis-related complaints, varicose veins or venous malformations were objectified in 57%. Edema was never a symptom of chronic venous disease. Duplex investigation is not often performed in children. In children with established deep venous thrombosis, a family history with deep venous thrombosis is common. In general, edema was not seen in children with varicose veins and, therefore, does not seem a reliable clinical sign at young age. © The Author(s) 2014.
[Venous tone of the limbs. Methods and comparison of 2 areas].
Journo, H; London, G; Pannier, B; Safar, M
1989-07-01
The limb venous tone, index of local venous compliance, was studied with mercury strain gauge plethysmography on 28 male normal subjects (40 +/- 17 years, +/- SD) simultaneously on upper and lower limbs. Measurements were done after 20 mn rest in supine position. Venous tone (VT) equals the slope of the pressure-volume curve established by simultaneous recording of the forearm and calf relative volumes for successive steps of pressure lower than or equal to 30 mmHg. Limb venous capacitance was expressed by means of the maximal limb relative volume (V30) reached for a pressure of 30 mmHg applied through cuffs in standardized conditions. The upper limb venous tone was greater than the lower limb venous tone: 24.3 +/- 8.2 mmHg/ml/100 vs 17.5 +/- 7.9 mmHg/ml/100, p = 0.001. V30 was greater in lower limb than in upper limb: 1.5 +/- 0.5 ml/100 vs 1.1 +/- 0.4 ml/100, p = 0.001. In conclusion, it appears that upper and lower limbs venous distensibility and capacitance are different. They are greater in the lower limb in baseline conditions. Thus simultaneous studies of both these limb venous systems seems important for physiological experiments because of their baseline differences.
Nakauchi, Kana; Kawazoe, Hitoshi; Miyajima, Risa; Waizumi, Chieko; Rokkaku, Yuki; Tsuneoka, Kikue; Higuchi, Noriko; Fujiwara, Mitsuko; Kojima, Yoh; Yakushijin, Yoshihiro
2015-11-01
Venous pain induced by oxaliplatin(L-OHP)is a clinical issue related to adherence to the Cape OX regimen. To prevent LOHP- induced venous pain, we provided nursing care to outpatients who were administered a preheated L -OHP diluted solution using a hot compress. We retrospectively evaluated the risk factors for colorectal cancer patients who had L -OHP induced phlebitis and venous pain. Furthermore, the preventive effect of nursing care was compared between inpatients and outpatients from January 2010 to March 2012. At the L-OHP administration site, any symptoms were defined as phlebitis, whereas pain was defined as venous pain. A total of 132 treatment courses among 31 patients were evaluated. Multivariate logistic regression analysis revealed that both phlebitis and venous pain were significantly more common in female patients (adjusted odds ratio, 2.357; 95%CI: 1.053-5.418; and adjusted odds ratio, 5.754; 95%CI: 2.119-18.567, respectively). The prevalence of phlebitis and venous pain did not differ between inpatients and outpatients (phlebitis, 61.3% vs 67.7%; venous pain, 29.0%vs 19.4%). These results suggest that administration of L-OHP via a central venous route should be considered in female patients.
Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G
2011-01-01
Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.
Sugita, Chihiro; Yamashita, Atsushi; Matsuura, Yunosuke; Iwakiri, Takashi; Okuyama, Nozomi; Matsuda, Shuntaro; Matsumoto, Tomoko; Inoue, Osamu; Harada, Aya; Kitazawa, Takehisa; Hattori, Kunihiro; Shima, Midori; Asada, Yujiro
2013-07-01
Elevated plasma levels of factor VIII (FVIII) are associated with increased risk of deep venous thrombosis. The aim of this study is to elucidate how elevated FVIII levels affect venous thrombus formation and propagation in vivo. We examined rabbit plasma FVIII activity, plasma thrombin generation, whole blood coagulation, platelet aggregation and venous wall thrombogenicity before and one hour after an intravenous infusion of recombinant human FVIII (rFVIII). Venous thrombus induced by the endothelial denudation of rabbit jugular veins was histologically assessed. Thrombus propagation was evaluated as indocyanine green fluorescence intensity. Argatroban, a thrombin inhibitor, and neutralised antibodies for tissue factor (TF), factor XI (FXI), and von Willebrand factor (VWF) were infused before or after thrombus induction to investigate their effects on venous thrombus formation or propagation. Recombinant FVIII (100 IU/kg) increased rabbit plasma FVIII activity two-fold and significantly enhanced whole blood coagulation and total plasma thrombin generation, but did not affect initial thrombin generation time, platelet aggregation and venous wall thrombogenicity. The rFVIII infusion also increased the size of venous thrombus 1 hour after thrombus induction. Argatroban and the antibodies for TF, FXI or VWF inhibited such enhanced thrombus formation and all except TF suppressed thrombus propagation. In conclusion, elevated plasma FVIII levels enhance venous thrombus formation and propagation. Excess thrombin generation by FXI and VWF-mediated FVIII recruitment appear to contribute to the growth of FVIII-driven venous thrombus.
Cortical venous disease severity in MELAS syndrome correlates with brain lesion development.
Whitehead, M T; Wien, M; Lee, B; Bass, N; Gropman, A
2017-08-01
MELAS syndrome is a mitochondrial disorder typified by recurrent stroke-like episodes, seizures, and progressive brain injury. Abnormal mitochondria have been found in arterial walls implicating a vasculogenic etiology. We have observed abnormal cortical vein T2/FLAIR signal in MELAS patients, potentially representing wall thickening and sluggish flow. We sought to examine the relationship of hyperintense veins and brain lesions in MELAS. Imaging databases at two children's hospitals were searched for brain MRIs from MELAS patients. Artifact, sedated exams, and lack of 2D-T2/FLAIR sequences were exclusion criteria. Each exam was assigned a venous score based on number of T2/FLAIR hyperintense veins: 1 = <10, 2 = 10 to 20, 3 = >20. Cumulative brain lesions and venous score in MELAS and aged-matched normal exams were compared by Mann-Whitney test. A total of 106 exams from 14 unique MELAS patients (mean 16 ± 3 years) and 30 exams from normal aged-matched patients (mean 15 ± 3 years) were evaluated. Median venous score between MELAS and control patients significantly differed (3 versus 1; p < 0.001). In the MELAS group, venous score correlated with presence (median = 3) or absence (median = 1) of cumulative brain lesions. In all 8 MELAS patients who developed lesions, venous hyperintensity was present prior to, during, and after lesion onset. Venous score did not correlate with brain lesion acuity. Abnormal venous signal correlates with cumulative brain lesion severity in MELAS syndrome. Cortical venous stenosis, congestion, and venous ischemia may be mechanisms of brain injury. Identification of cortical venous pathology may aid in diagnosis and could be predictive of lesion development.
Armenteros-Yeguas, Victoria; Gárate-Echenique, Lucía; Tomás-López, Maria Aranzazu; Cristóbal-Domínguez, Estíbaliz; Moreno-de Gusmão, Breno; Miranda-Serrano, Erika; Moraza-Dulanto, Maria Inmaculada
2017-12-01
To estimate the prevalence of difficult venous access in complex patients with multimorbidity and to identify associated risk factors. In highly complex patients, factors like ageing, the need for frequent use of irritant medication and multiple venous catheterisations to complete treatment could contribute to exhaustion of venous access. A cross-sectional study was conducted. 'Highly complex' patients (n = 135) were recruited from March 2013-November 2013. The main study variable was the prevalence of difficult venous access, assessed using one of the following criteria: (1) a history of difficulties obtaining venous access based on more than two attempts to insert an intravenous line and (2) no visible or palpable veins. Other factors potentially associated with the risk of difficult access were also measured (age, gender and chronic illnesses). Univariate analysis was performed for each potential risk factor. Factors with p < 0·2 were then included in multivariable logistic regression analysis. Odds ratios were also calculated. The prevalence of difficult venous access was 59·3%. The univariate logistic regression analysis indicated that gender, a history of vascular access complications and osteoarticular disease were significantly associated with difficult venous access. The multivariable logistic regression showed that only gender was an independent risk factor and the odds ratios was 2·85. The prevalence of difficult venous access is high in this population. Gender (female) is the only independent risk factor associated with this. Previous history of several attempts at catheter insertion is an important criterion in the assessment of difficult venous access. The prevalence of difficult venous access in complex patients is 59·3%. Significant risk factors include being female and a history of complications related to vascular access. © 2017 John Wiley & Sons Ltd.
Li, Fenghe; Wang, Xuehu; Huang, Wen; Ren, Wei; Cheng, Jun; Zhang, Mao; Zhao, Yu
2014-08-01
The aim of our study is to investigate the prevalence of silent pulmonary embolism in patients with deep venous thrombosis in the lower limbs and to evaluate the associated risk factors. A total of 322 patients with acute deep venous thrombosis confirmed by CT venography or Doppler ultrasonography were studied. The diagnosis of silent pulmonary embolism was established by computed tomography pulmonary arteriography (CTPA). The association between covariates and the prevalence of silent pulmonary embolism in patients with deep venous thrombosis in lower limbs were assessed using chi-square test and multivariable regression. The incidence of silent pulmonary embolism was 33.5% (108 in 322 patients) in all patients with deep venous thrombosis in lower limbs. Chi-square test showed male gender, the right lower limb, proximal location of the thrombus, unprovoked venous thrombosis and coexisting heart diseases were related to a higher incidence of silent pulmonary embolism in patients with deep venous thrombosis in lower limbs. The multivariate regression analysis confirmed that the risk factors associated with silent pulmonary embolism in deep venous thrombosis patients included the right side and proximal location of the thrombus (odds ratio: 2.023, 95% CI: 1.215-3.368; odds ratio: 3.610, 95% CI: 1.772-7.354), unprovoked venous thrombosis (odds ratio: 2.037, 95% CI: 1.188-3.493), coexisting heart diseases (odds ratio: 4.507, 95% CI: 2.667-7.618). Silent pulmonary embolism occurred frequently in patients with deep venous thrombosis in lower limbs. The right side, the proximal location of the thrombus, unprovoked venous thrombosis and coexisting heart diseases increased the risk for the occurrence of silent pulmonary embolism. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
A mobile compression device for thrombosis prevention in hip and knee arthroplasty.
Colwell, Clifford W; Froimson, Mark I; Anseth, Scott D; Giori, Nicholas J; Hamilton, William G; Barrack, Robert L; Buehler, Knute C; Mont, Michael A; Padgett, Douglas E; Pulido, Pamela A; Barnes, C Lowery
2014-02-05
Venous thromboembolic events, either deep venous thrombosis or pulmonary embolism, are important complications in patients undergoing knee or hip arthroplasty. The purpose of this study was to evaluate the effectiveness of a mobile compression device (ActiveCare+S.F.T.) with or without aspirin compared with current pharmacological protocols for prophylaxis against venous thromboembolism in patients undergoing elective primary unilateral arthroplasty of a lower-extremity joint. A multicenter registry was established to capture the rate of symptomatic venous thromboembolic events following primary knee arthroplasty (1551 patients) or hip arthroplasty (1509 patients) from ten sites. All patients were eighteen years of age or older with no known history of venous thromboembolism, coagulation disorder, or solid tumor. Use of the compression device began perioperatively and continued for a minimum of ten days. Patients with symptoms of deep venous thrombosis or pulmonary embolism underwent duplex ultrasonography and/or spiral computed tomography. All patients were evaluated at three months postoperatively to document any evidence of deep venous thrombosis or pulmonary embolism. Of 3060 patients, twenty-eight (0.92%) had venous thromboembolism (twenty distal deep venous thrombi, three proximal deep venous thrombi, and five pulmonary emboli). One death occurred, with no autopsy performed. Symptomatic venous thromboembolic rates observed in patients who had an arthroplasty of a lower-extremity joint using the mobile compression device were noninferior (not worse than), at a margin of 1.0%, to the rates reported for pharmacological prophylaxis, including warfarin, enoxaparin, rivaroxaban, and dabigatran, except in the knee arthroplasty group, in which the mobile compression device fell short of the rate reported for rivaroxaban by 0.06%. Use of the mobile compression device with or without aspirin for patients undergoing arthroplasty of a lower-extremity joint provides a noninferior risk for the development of venous thromboembolism compared with current pharmacological protocols.
Spanos, K; De Maeseneer, M; Nicolaides, A; Giannoukas, A D
2015-04-01
Venous training in Europe is lacking a formal curriculum among various specialties related to management of venous diseases. We conducted a survey in order to have a snapshot on the actual education and training level among physicians practicing currently venous surgery and phlebology in Europe. From April 7, 2014 to June 11, 2014 a survey was carried out using the Survey Monkey system, including 11 main questions covering all the domains of training and education in venous surgery and phlebology. The questionnaire was sent to all physicians included in the current mailing list of the European Venous Forum (EVF) and the Mediterranean League of Angiology and Vascular Surgery. Two questions were particularly addressed to those physicians who had attended the EVF hands-on workshop (HOW) at least once. The response rate was 24% (97/400) and 51.5% of them were practicing in a hospital service. Most responders were vascular surgeons (67.7%), followed by angiologists (19.4%). Only half of the responders felt as being competent to manage the whole spectrum of venous diseases successfully after completion of their training, while a few were able to perform endovenous ablations and even less more advanced venous interventions. Formal training in Duplex ultrasound was undertaken only in 55.2%. The majority suggested that a venous training program should be a separate part of their specialty rotation and should be organized at a national or European level, or even by a specific scientific society. Over 95% of those physicians who already participated in the EVF HOW considered the knowledge they acquired there as useful for their practice. There is currently an important need for more specialized venous training for all physicians involved in the diagnosis and management of venous diseases. Therefore all local, national and international initiatives should be encouraged to improve education in this field.
Ambulatory Status Protects Against Venous Thromboembolism in Acute Mild Ischemic Stroke Patients
Sisante, Jason-Flor V.; Abraham, Michael G.; Phadnis, Milind A.; Billinger, Sandra A.; Mittal, Manoj K.
2016-01-01
Introduction Ischemic stroke patients are at high risk (up to 18%) for venous thromboembolism. We conducted a retrospective cross-sectional study to understand the predictors of acute post-mild ischemic stroke patient’s ambulatory status and its relationship with venous thromboembolism, hospital length of stay, and in-hospital mortality. Methods We identified 522 patients between February 2006 and May 2014 and collected data about patient demographics, admission NIHSS, venous thromboembolism prophylaxis, ambulatory status, diagnosis of venous thromboembolism, and hospital outcomes (length of stay, mortality). Chi-square tests, t-test and Wilcoxon Ranks Sum tests, and binary logistic regression were used for statistical analysis as appropriate. Results A total of 61 (11.7%), 48 (9.2%), and 23 (4.4%) mild ischemic stroke patients developed venous thromboembolism, deep venous thrombosis, and pulmonary embolism, respectively. During hospitalization, 281 (53.8%) patients were ambulatory. Independent predictors of in-hospital ambulation were being married (OR 1.64, 95% CI 1.10–2.49), being non-religious (OR 2.19, 95% CI 1.34–3.62), admission NIHSS (per unit decrease in NIHSS; OR 1.62, 95% CI 1.39–1.91), and non-usage of mechanical venous thromboembolism prophylaxis (OR 1.62, 95% CI 1.02–2.61). After adjusting for confounders, ambulatory patients had lower rates of venous thromboembolism (OR 0.47, 95% CI 0.25–0.89), deep venous thrombosis (OR 0.36, 95% CI 0.17–0.73), prolonged length of hospital stay (OR 0.24, 95% CI 0.16–0.37), and mortality (OR 0.43, 95% CI 0.21–0.84). Conclusions Our findings suggest that for hospitalized acute mild ischemic stroke patients, ambulatory status is an independent predictor of venous thromboembolism (specifically deep venous thrombosis), hospital length of stay, and in-hospital mortality. PMID:27423367
Parsa, Cameron F.
2013-01-01
Purpose: To provide an in-depth re-examination of assumed causes of tissue hypertrophy, port-wine stains, and the Sturge-Weber, Cobb, Klippel-Trénaunay, and related syndromes to support an alternative unifying pathophysiologic mechanism of venous dysplasia producing focal venous hypertension with attendant tissue responses; to provide proof of concept with new patient data; to propose a novel etiological hypothesis for the venous dysplasia in these syndromes and find supportive evidence. Methods: Data from 20 patients with port-wine stains and corneal pachymetry readings was collected prospectively by the author in an institutional referral-based practice. The literature was searched using MEDLINE, and articles and textbooks were obtained from the bibliographies of these publications. Results: Newly obtained dermatologic, corneal pachymetry, fundus ophthalmoscopic, ocular and orbital venous Doppler ultrasonography, and magnetic resonance imaging findings in patients with the Sturge-Weber syndrome or isolated port-wine stains, along with published data, reveal diffusely thickened tissues and neural atrophy in all areas associated with venous congestion. Conclusions: Contrary to traditional understanding, signs and symptoms in the Sturge-Weber and related syndromes, including both congenital and acquired port-wine stains, are shown to arise from effects of localized primary venous dysplasia or acquired venous obstruction rather than neural dysfunction, differentiating these syndromes from actual phacomatoses. Effects of focal venous hypertension are transmitted to nearby areas via compensatory collateral venous channels in the above conditions, as in the Parkes Weber syndrome. A novel underlying etiology—prenatal venous thrombo-occlusion—is proposed to be responsible for the absence of veins with persistence and enlargement of collateral circulatory pathways with data in the literature backing this offshoot hypothesis. The mechanism for isolated pathologic tissue hypertrophy in these syndromes clarifies physiologic mechanisms for exercise-induced muscle hypertrophy to occur via venous compression and increased capillary transudation. PMID:24385674
Che, J; Tian, M; Ding, G; Huai, Q; Dong, P; Li, Y; Li, S
2013-08-01
The aim of this study was to investigate the contribution of the perioperative cell salvage process to the changes in erythrocyte 2,3-disphosphoglycerate (2,3-DPG) and glucose-6-phosphate dehydrogenase (G-6-PD) levels and phosphatidylserine (PS) expression using a self-control study comparing washed blood with venous blood. Thirty patients undergoing elective heart and blood vessel surgery were enrolled. Blood was collected and processed using a Fresenius continuous autotransfusion system device. 2,3-DPG and G-6-PD activities, as well as PS expression, from both venous and washed red blood cells (RBC) were measured. We also compared these indicators among washed RBC at 6 h, washed RBC at 0 h, and venous RBC. 2,3-DPG and G-6-PD activities in washed blood at 0 h were significantly higher than in venous RBC (2,3-DPG, venous vs. washed blood P < 0.05; G-6-PD, venous vs. washed blood P < 0.05). Flow cytometry results showed no differences between venous blood and washed RBC at 0 h (n = 23, P > 0.05). 2,3-DPG activity in washed RBC that were allowed to stand for 6 h decreased compared with that in venous blood (venous vs. washed blood at 6 h P < 0.01), whereas no significant difference was observed in G-6-PD activity (venous. vs. washed blood at 6 h P > 0.05). Compared with venous RBC, washed RBC from intraoperative cell salvage exhibited good oxygen-carrying and antioxidant capacities. However, the oxygen-carrying capacity of washed RBC that were allowed to stand for 6 h was not as good as that of venous RBC. Thus, we suggest that washed RBC that were left to stand for more than 6 h should not be reinfused. © 2012 John Wiley & Sons Ltd.
Venous thromboembolism prophylaxis in gynecologic surgery: a systematic review.
Rahn, David D; Mamik, Mamta M; Sanses, Tatiana V D; Matteson, Kristen A; Aschkenazi, Sarit O; Washington, Blair B; Steinberg, Adam C; Harvie, Heidi S; Lukban, James C; Uhlig, Katrin; Balk, Ethan M; Sung, Vivian W
2011-11-01
To comprehensively review and critically assess the available gynecologic surgery venous thromboembolism prophylaxis literature and provide clinical practice guidelines. MEDLINE and Cochrane databases from inception to July 2010. We included randomized controlled trials in gynecologic surgery populations. Interventions and comparators included graduated compression stockings, intermittent pneumatic compression, unfractionated heparin, and low molecular weight heparin; placebo and routine postoperative care were allowed as comparators. One thousand two hundred sixty-six articles were screened, and 14 randomized controlled trials (five benign gynecologic, nine gynecologic oncology) met eligibility criteria. In addition, nine prospective or retrospective studies with at least 150 women were identified and provided data on venous thromboembolism risk stratification, gynecologic laparoscopy, and urogynecologic populations. Two reviewers independently screened articles with discrepancies adjudicated by a third. Eligible randomized controlled trials were extracted for these characteristics: study, participant, surgery, intervention, comparator, and outcomes data, including venous thromboembolism incidence and bleeding complications. Studies were individually and collectively assessed for methodologic quality and strength of evidence. Overall incidence of clinical venous thromboembolism was 0-2% in the benign gynecologic population. With use of intermittent pneumatic compression for benign major procedures, venous thromboembolism incidence was less than 1%. No venous thromboembolisms were identified in prospective studies of benign laparoscopic procedures. Overall quality of evidence in the benign gynecologic literature was poor. Gynecologic-oncology randomized controlled trials reported venous thromboembolism incidence (including "silent" venous thromboembolisms) of 0-14.8% with prophylaxis and up to 34.6% without prophylaxis. Fair quality of evidence supports that unfractionated heparin and intermittent pneumatic compression are both superior to placebo or no intervention but insufficient to determine whether heparins are superior to intermittent pneumatic compression for venous thromboembolism prevention. Combining two of three risks (aged 60 years or older, cancer, or personal venous thromboembolism history) substantially elevated the risk of venous thromboembolism. Intermittent pneumatic compression provides sufficient prophylaxis for the majority of gynecology patients undergoing benign surgery. Additional risk factors warrant the use of combined mechanical and pharmacologic prophylaxis.
Addendum to "Compact Perturbative Expressions for Neutrino Oscillations in Matter"
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denton, Peter B.; Minakata, Hisakazu; Parke, Stephen J.
2018-01-19
In this paper we rewrite the neutrino mixing angles and mass squared differences in matter given, in our original paper, in a notation that is more conventional for the reader. Replacing the usual neutrino mixing angles and mass squared differences in the expressions for the vacuum oscillation probabilities with these matter mixing angles and mass squared differences gives an excellent approximation to the oscillation probabilities in matter. Comparisons for T2K, NOvA, T2HKK and DUNE are also given for neutrinos and anti-neutrinos, disappearance and appearance channels, normal ordering and inverted ordering.
Venous and autonomic function in formerly pre-eclamptic women and BMI-matched controls.
Heidema, Wieteke M; van Drongelen, Joris; Spaanderman, Marc E A; Scholten, Ralph R
2018-03-25
Pre-pregnancy reduced plasma volume increases the risk on subsequent pre-eclamptic pregnancy. Reduced plasma volume is thought to reflect venous reserve capacity, especially when venous vasculature is constricted and sympathetic tone is elevated. As obesity might affect these variables and also relates to pre-eclampsia, increased body weight may underlie these observations. We hypothesized that the relationship between reduced venous reserve and preeclampsia is independent of body mass index (BMI). We compared the non-pregnant venous reserve capacity in 30 formerly pre-eclamptic women, equally divided in 3 BMI-classes (BMI 19.5-24.9, BMI 25-29.9, BMI ≥30) to 30 controls. Cases and controls were matched for BMI, age and parity. The venous reserve capacity was quantified by assessing plasma volume and venous compliance. The autonomic nervous system regulating the venous capacitance was evaluated with heart rate variability analysis in resting supine position and during positive head-up tilt (HUT). Formerly pre-eclamptic women had in supine position lower plasma volume than controls (1339 ± 79 vs 1547 ± 139 ml/m 2 (p<0.001)), lower venous compliance (0.04 ± 0.02 vs 0.07 ± 0.02 ml/dl/mmHg (p<0.001)), higher sympathetic tone (1.9 ± 0.1 vs 1.2 ± 0.7 mmHg 2 (p=0.002)) and lower baroreceptor sensitivity (8.7 ± 3.8 vs 19.0 ± 1.7 ms/mmHg (p<0.001)). During HUT, women with a history of preeclampsia have less modulatory capacity over venous compliance and baroreceptor sensitivity, while heart rate and sympathetic tone remain consistently higher. Women with a history of pre-eclampsia have, compared to BMI-matched controls, reduced venous reserve capacity. This is reflected by lower plasma volume and venous compliance, the autonomic balance is shifted towards sympathetic dominance and lower baroreceptor sensitivity. This suggests that not BMI, but underlying reduced venous reserve relates to pre-eclampsia. This article is protected by copyright. All rights reserved.
Stranix, John T; Rifkin, William J; Lee, Z-Hye; Anzai, Lavinia; Jacoby, Adam; Ceradini, Daniel J; Thanik, Vishal; Saadeh, Pierre B; Levine, Jamie P
2018-06-15
Microvascular reconstruction of the lower extremity has the highest reported complication and flap failure rates of any anatomical region. Despite widespread adoption of the mechanical anastomotic venous coupler and encouraging results in other anatomical regions, there are limited reports examining its use in the lower extremity. This study compares outcomes between coupled and hand-sewn venous anastomoses in traumatic lower extremity reconstruction. Retrospective review of our institutional flap registry from 1979 to 2016 identified soft tissue free flaps performed for the reconstruction of Gustilo type IIIB/IIIC open tibial fractures. Patient demographics, flap characteristics, use of a venous anastomotic coupler, and perioperative outcomes were examined. Analysis was performed using chi-square and Student's t -tests. A total of 361 patients received a microvascular free flap for coverage of a Gustilo type IIIB or IIIC tibial fracture following traumatic injury. After excluding cases that lacked adequate information on coupler use, 358 free flaps were included in the study. There were 72 (20%) free flaps performed using a venous coupler and 286 (80%) performed with hand-sewn venous anastomoses. There were comparable rates of major complications (22.2 vs. 26.1%; p = 0.522), total flap failure (6.5%, vs. 10.2%; p = 0.362), and partial flap failure (9.7 vs. 12.2%; p = 0.579) between venous coupler and hand-sewn anastomoses, respectively. Furthermore, use of the venous coupler was not associated with increased rates of operative take backs (22.8 vs. 23.0%; p = 0.974). However, reconstructions performed using a venous coupler were significantly more likely to have a second venous anastomosis performed (37.5 vs. 21.3%; p = 0.004). Complication and flap failure rates were similar between reconstructions performed with a venous coupler and those performed with hand-sewn venous anastomoses. These findings suggest that use of the venous anastomotic coupler is safe and effective in lower extremity reconstruction, with comparable outcomes to conventional sutured anastomoses. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.
Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban
2018-01-01
Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.
The imaging and modelling of the physical processes involved in digestion and absorption.
Schulze, K S
2015-02-01
The mechanical activity of the gastro-intestinal tract serves to store, propel and digest food. Contractions disperse particles and transform solids and secretions into the two-phase slurry called chyme; movements of the intestine deliver nutrients to mucosal sites of absorption, and from the submucosa into the lymphatic and portal venous circulation. Colonic motor activity helps to extract fluid and electrolytes from chyme and to compound and compact luminal debris into faeces for elimination. We outline how dynamic imaging by ultrasound and magnetic resonance can demonstrate intestinal flow processes critical to digestion like mixing, dilution, swelling, dispersion and elution. Computational fluid mechanics enables a numerical rendition of the forces promoting digestion: pressure and flow fields, the shear stresses dispersing particles or the effectiveness of bolus mixing can be calculated. These technologies provide new insights into the mechanical processes that promote digestion and absorption. © 2014 This article is a U.S. Government work and is in the public domain in the USA.
Effects of type of diet on pharmacokinetics of levothyroxine sodium oral solution.
Iemura, Ryuji; Toyota, Masanori; Micallef, Mark J
2013-06-01
The pharmacokinetics of serum total thyroxine concentration (TT4) in euthyroid dogs was studied after concomitant administration of a levothyroxine oral solution with different types of dry diet. Mixing levothyroxine with different types of dry diet did not have any effect on TT4 pharmacokinetics in the dogs (Cmax 50.6 nmol/L, tmax 4.0 h and AUC 517 nmol h/L). This finding indicates that changing from one diet to another during levothyroxine-replacement therapy should not impact therapeutic effectiveness, and should be helpful for improvement of compliance with thyroid hormone replacement therapy in dogs treated for life with this replacement therapy. Copyright © 2013 Elsevier Ltd. All rights reserved.
Huang, Shuai; Xu, Feng; Wang, Yin-Ye; Shang, Ming-Ying; Wang, Chao-Qun; Wang, Xuan; Cai, Shao-Qing
2014-12-23
To establish a novel cardiocentesis method for withdrawing venous blood from the right atrium, and to improve an acute blood stasis rat model using an ice bath and epinephrine hydrochloride (Epi) while considering the 3Rs (reduction, refinement, and replacement) of humane animal experimentation. An acute blood stasis model was established in male Sprague-Dawley rats by subcutaneous injection (s.c.) Epi (1.2 mg/kg) administration at 0 h, followed by a 5-min exposure to an ice-bath at 2 h and s.c. Epi administration at 4 h. Control rats received physiological saline. Rats were fasted overnight and treated with Angelicae Sinensis Lateralis Radix (ASLR) and Pheretima the following day. Venous blood was collected using our novel cardiocentesis method and used to test whole blood viscosity (WBV), prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen (FIB) content. The rats survived the novel cardiocentesis technique; WBV value returned to normal while hematological parameters such as hemoglobin level and red blood cell count were restored to >94% of the corresponding values in normal rats following a 14-day recovery. Epi (1.2 mg/kg, s.c.) combined with a 5-min exposure to the ice bath replicated the acute blood stasis rat model and was associated with the highest WBV value. In rats showing acute blood stasis, ASLR treatment [4 g/(kg·d) for 8 days] decreased WBV by 9.98%, 11.09%, 9.34%, 9.00%, 7.66%, and 7.03% (P<0.05), while Pheretima treatment [2.6 g/(kg·d), for 8 days] decreased WBV by 25.49%, 25.94%, 16.28%, 17.76%, 11.07%, and 7.89% (P<0.01) at shear rates of 1, 3, 10, 30, 100, and 180 s -1 , respectively. Furthermore, Pheretima treatment increased APTT significantly (P<0.01). We presented a stable, reproducible, and improved acute blood stasis rat model, which could be applied to screen drugs for promoting blood circulation and eliminating blood stasis.
Mitchell, Lesley G; Andrew, Maureen; Hanna, Kim; Abshire, Thomas; Halton, Jacqueline; Anderson, Ron; Cherrick, Irene; Desai, Sunil; Mahoney, Donald; McCuster, Patricia; Wu, John; Dahl, Gary; Chait, Peter; de Veber, Gabrielle; Lee, Kyong-Jin; Mikulis, David; Ginsberg, Jeffrey; Way, Cliford
2003-01-15
Thrombotic events (TEs) are serious secondary complications in children with acute lymphoblastic leukemia (ALL) who receive L-asparaginase (ASP) therapy; however, the prevalence of TEs has not been established. The primary objective of the Prophylactic Antithrombin Replacement in Kids with Acute Lymphoblastic Leukemia Treated with Asparaginase (PARKAA) Study was to determine the prevalence of TEs. The secondary objective was to detect any association of TEs with the presence of congenital or acquired prothrombotic disorders. Children with ALL were screened for TEs at the end of ASP treatment using bilateral venograms, ultrasound, magnetic resonance imaging, and echocardiography. Symptomatic TEs were confirmed by appropriate radiographic tests. All tests were read by a blinded central adjudication committee. Twenty-two of 60 children had TEs, a prevalence of 36.7% (95% confidence interval, 24.4-48.8%). TEs were located in the sinovenous system of the brain in 1 patient, the right atrium in 3 patients, and the upper central venous system in 19 patients. TEs detected by venography resulted in 1) 25-100% occlusion, with 1 in 3 patients showing occlusion of > 75% of the greatest vessel dimension, and 2) the presence of collaterals in 60% of patients, with 40% categorized as major. No children with TEs were positive for factor V Leiden or prothrombin gene 20201A, and four of eight children with antiphospholipid antibodies had a TE. The prevalence of TEs is exceedingly high in this population, and it is likely that the extent of occlusion is likely clinically significant. No trend was seen toward an association between TEs and the presence of congenital prothrombotic disorders. A trend was seen toward an association between TEs and antiphospholipid antibodies. Carefully designed clinical trials of primary prophylaxis for the prevention of TEs are required in this patient population. Copyright 2003 American Cancer Society
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, I.; Royal, H.D.; Uren, R.F.
1984-01-01
Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. Twenty-one patients with suspected deep venous thrombosis were studied prospectively using RPG, radionuclide venography (RV), and contrast venography (CV) to establish the usefulness of RPG alone and in combination wth RV in the diagnosis of ileofemoral venous thrombosis (sensitivity, 91%; specificity, 100%). RV was lessmore » sensitive (73%) and less specific (93%) in diagnosing that condition.« less
Warfarin-induced Venous Limb Gangrene
Grim Hostetler, Sarah; Sopkovich, Jennifer; Dean, Steven
2012-01-01
Warfarin is a commonly used anticoagulant that has been associated with several significant cutaneous side effects, most notably warfarin-induced skin necrosis. A lesser known adverse reaction to warfarin is warfarin-induced venous limb gangrene. Both cutaneous adverse effects share the same pathophysiology, but are clinically quite different. The majority of cases of warfarin-induced venous limb gangrene has been in patients with cancer or heparin-induced thrombocytopenia. However, other hypercoagulable disease states, such as the antiphospholipid antibody syndrome, can be associated with venous limb gangrene. In order to increase recognition of this important condition, the authors report a case of warfarin-induced venous limb gangrene in a patient with presumed antiphospholipid antibody syndrome and review the literature on warfarin-induced venous limb gangrene. PMID:23198012
Anomalous pulmonary venous connection: An underestimated entity.
Magalhães, Sara P; Moreno, Nuno; Loureiro, Marília; França, Manuela; Reis, Fernanda; Alvares, Sílvia; Ribeiro, Manuel
2016-12-01
Anomalous pulmonary venous connection is an uncommon congenital anomaly in which all (total form) or some (partial form) pulmonary veins drain into a systemic vein or into the right atrium rather than into the left atrium. The authors present one case of total anomalous pulmonary venous connection and two cases of partial anomalous pulmonary venous connection, one of supracardiac drainage into the brachiocephalic vein, and the other of infracardiac anomalous venous drainage (scimitar syndrome). Through the presentation of these cases, this article aims to review the main pulmonary venous developmental defects, highlighting the role of imaging techniques in the assessment of these anomalies. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Brugnara, Carlo; Betensky, Rebecca A.; Waikar, Sushrut S.
2015-01-01
Background and objectives Hypophosphatemia is a frequent complication during continuous renal replacement therapy (CRRT), a dialytic technique used to treat AKI in critically ill patients. This study sought to confirm that phosphate depletion during CRRT may decrease red blood cell (RBC) concentration of 2,3-diphosphoglycerate (2,3-DPG), a crucial allosteric effector of hemoglobin’s (Hgb’s) affinity for oxygen, thereby leading to impaired oxygen delivery to peripheral tissues. Design, setting, participants, & measurements Phosphate mass balance studies were performed in 20 patients with severe AKI through collection of CRRT effluent. RBC concentrations of 2,3-DPG, venous blood gas pH, and oxygen partial pressure required for 50% hemoglobin saturation (P50) were measured at CRRT initiation and days 2, 4, and 7. Similar measurements were obtained on days 0 and 2 in a reference group of 10 postsurgical patients, most of whom did not have AKI. Associations of 2,3-DPG with laboratory parameters and clinical outcomes were examined using mixed-effects and Cox regression models. Results Mean 2,3-DPG levels decreased from a mean (±SD) of 13.4±3.4 µmol/g Hgb to 11.0±3.1 µmol/g Hgb after 2 days of CRRT (P<0.001). Mean hemoglobin saturation P50 levels decreased from 29.7±4.4 mmHg to 26.7±4.0 mmHg (P<0.001). No significant change was seen in the reference group. 2,3-DPG levels after 2 days of CRRT were not significantly lower than those in the reference group on day 2. Among patients receiving CRRT, 2,3-DPG decreased by 0.53 µmol/g Hgb per 1 g phosphate removed (95% confidence interval 0.38 to 0.68 µmol/g Hgb; P<0.001). Greater reductions in 2,3-DPG were associated with higher risk for death (hazard ratio, 1.43; 95% confidence interval, 1.09 to 1.88; P=0.01). Conclusions CRRT-induced phosphate depletion is associated with measurable reductions in RBC 2,3-DPG concentration and a shift in the O2:Hgb affinity curve even in the absence of overt hypophosphatemia. 2,3-DPG reductions may be associated with higher risk for in-hospital death and represent a potentially avoidable complication of CRRT. PMID:25538269
Sharma, Shilpa; Brugnara, Carlo; Betensky, Rebecca A; Waikar, Sushrut S
2015-01-07
Hypophosphatemia is a frequent complication during continuous renal replacement therapy (CRRT), a dialytic technique used to treat AKI in critically ill patients. This study sought to confirm that phosphate depletion during CRRT may decrease red blood cell (RBC) concentration of 2,3-diphosphoglycerate (2,3-DPG), a crucial allosteric effector of hemoglobin's (Hgb's) affinity for oxygen, thereby leading to impaired oxygen delivery to peripheral tissues. Phosphate mass balance studies were performed in 20 patients with severe AKI through collection of CRRT effluent. RBC concentrations of 2,3-DPG, venous blood gas pH, and oxygen partial pressure required for 50% hemoglobin saturation (P50) were measured at CRRT initiation and days 2, 4, and 7. Similar measurements were obtained on days 0 and 2 in a reference group of 10 postsurgical patients, most of whom did not have AKI. Associations of 2,3-DPG with laboratory parameters and clinical outcomes were examined using mixed-effects and Cox regression models. Mean 2,3-DPG levels decreased from a mean (±SD) of 13.4±3.4 µmol/g Hgb to 11.0±3.1 µmol/g Hgb after 2 days of CRRT (P<0.001). Mean hemoglobin saturation P50 levels decreased from 29.7±4.4 mmHg to 26.7±4.0 mmHg (P<0.001). No significant change was seen in the reference group. 2,3-DPG levels after 2 days of CRRT were not significantly lower than those in the reference group on day 2. Among patients receiving CRRT, 2,3-DPG decreased by 0.53 µmol/g Hgb per 1 g phosphate removed (95% confidence interval 0.38 to 0.68 µmol/g Hgb; P<0.001). Greater reductions in 2,3-DPG were associated with higher risk for death (hazard ratio, 1.43; 95% confidence interval, 1.09 to 1.88; P=0.01). CRRT-induced phosphate depletion is associated with measurable reductions in RBC 2,3-DPG concentration and a shift in the O2:Hgb affinity curve even in the absence of overt hypophosphatemia. 2,3-DPG reductions may be associated with higher risk for in-hospital death and represent a potentially avoidable complication of CRRT. Copyright © 2015 by the American Society of Nephrology.
NASA Astrophysics Data System (ADS)
Sheikh Khalid, Faisal; Bazilah Azmi, Nurul; Natasya Mazenan, Puteri; Shahidan, Shahiron; Ali, Noorwirdawati
2018-03-01
This research focuses on the performance of composite sand cement brick containing recycle concrete aggregate and waste polyethylene terephthalate. This study aims to determine the mechanical properties such as compressive strength and water absorption of composite brick containing recycled concrete aggregate (RCA) and polyethylene terephthalate (PET) waste. The bricks specimens were prepared by using 100% natural sand, they were then replaced by RCA at 25%, 50% and 75% with proportions of PET consists of 0.5%, 1.0% and 1.5% by weight of natural sand. Based on the results of compressive strength, only RCA 25% with 0.5% PET achieve lower strength than normal bricks while others showed a high strength. However, all design mix reaches strength more than 7N/mm2 as expected. Besides that, the most favorable mix design that achieves high compressive strength is 75% of RCA with 0.5% PET.
An Isolated Venous Sac as a Novel Site for Cell Therapy in Diabetes Mellitus
Kakabadze, Zurab; Shanava, Koba; Ricordi, Camillo; Shapiro, A.M. James; Gupta, Sanjeev; Berishvili, Ekaterine
2013-01-01
Background Transplanting pancreatic islets is of significant interest for type 1 diabetes mellitus. After intraportal injection of islets, inferior engraftment and eventual loss of transplanted islets constitute major limitations. Therefore, alternative approaches will be helpful. Here, we evaluated in animals whether an isolated venous sac would support survival of transplanted islets, along with correction of hyperglycemia. Methods Pancreatic islets isolated from adult Lewis rats were transplanted either into an isolated venous sac made from lumbar vein or into the portal vein of syngeneic rats. The integrity and vascular organization of the venous sac was determined by studies of the local microcirculation. The engraftment, survival, and function of transplanted islets were analyzed by histology, including endocrine function in situ and by glycemic control in rats with streptozotocin-induced diabetes. Results Transplanted islets showed normal morphology with insulin expression in isolated venous sac during the long term. Transplanted islets received blood supply from vasa vasorum and had access to drainage through venous tributaries in the venous sac. This resulted in restoration of euglycemia in diabetic rats. Removal of islet graft-bearing venous sac in diabetic rats led to recurrence of hyperglycemia. By contrast, euglycemia was not restored in rats treated by intraportal transplantation of islets. Conclusions We demonstrated that pancreatic islets successfully engrafted and functioned in the isolated venous sac with ability to restore euglycemia in diabetic rats. Therefore, the isolated venous sac offers a new site for transplantation of pancreatic islets. This would be clinically beneficial as an alternative to intrahepatic islet transplantation. PMID:22814331
Rau, Aline S; Harry, Brian L; Leem, Ted H; Song, John I; Deleyiannis, Frederic W-B
2016-08-01
The purpose of this study was to investigate the incidence of symptomatic and asymptomatic deep venous thrombosis in patients undergoing harvest of a free flap from the lower extremity who were receiving standard chemoprophylaxis while hospitalized. A retrospective review of 65 consecutive patients undergoing surgery between 2011 and 2013 was performed to determine the incidence of symptomatic deep venous thrombosis. These patients were screened for deep venous thrombosis based on development of symptoms. Prospective evaluation of a similar consecutive population of 37 patients between 2014 and 2015 was then performed to determine the incidence of asymptomatic deep venous thrombosis. These patients underwent routine duplex ultrasonography of both legs at postoperative weeks 1 and 4. Symptomatic deep venous thrombosis occurred in 2.9 percent of all patients. In the prospective cohort, 8.1 percent of the patients were found to have an acute deep venous thrombosis by postoperative week 1. At postoperative week 4, 16.7 percent of the patients developed a new, acute deep venous thrombosis. The estimated costs of screening and treating deep venous thrombosis in the retrospective group and the prospective group were $222 and $2259, respectively. The cost of routine chemoprophylaxis without duplex screening for an additional 14 days after discharge was $125 per patient. The rate of asymptomatic deep venous thrombosis may be much higher than previously appreciated in this population of very high-risk patients, especially during the 2 weeks after discharge. Extending the duration of chemoprophylaxis to 4 weeks after surgery may be warranted. Therapeutic, IV.
Lifetime Risk of Venous Thromboembolism in Two Cohort Studies.
Bell, Elizabeth J; Lutsey, Pamela L; Basu, Saonli; Cushman, Mary; Heckbert, Susan R; Lloyd-Jones, Donald M; Folsom, Aaron R
2016-03-01
Greater public awareness of venous thromboembolism may be an important next step for optimizing venous thromboembolism prevention and treatment. "Lifetime risk" is an easily interpretable way of presenting risk information. Therefore, we sought to calculate the lifetime risk of venous thromboembolism (deep vein thrombosis or pulmonary embolism) using data from 2 large, prospective cohort studies: the Cardiovascular Health Study (CHS) and the Atherosclerosis Risk in Communities (ARIC) study. We followed participants aged 45-64 years in ARIC (n = 14,185) and ≥65 in CHS (n = 5414) at baseline visits (1987-1989 in ARIC, 1989-1990 and 1992-1993 in CHS) for incident venous thromboembolism (n = 728 in ARIC through 2011 and n = 172 in CHS through 2001). We estimated lifetime risks and 95% confidence intervals of incident venous thromboembolism using a modified Kaplan-Meier method, accounting for the competing risk of death from other causes. At age 45 years, the remaining lifetime risk of venous thromboembolism in ARIC was 8.1% (95% confidence interval, 7.1-8.7). High-risk groups were African Americans (11.5% lifetime risk), those with obesity (10.9%), heterozygous for the factor V Leiden (17.1%), or with sickle cell trait or disease (18.2%). Lifetime risk estimates differed by cohort; these differences were explained by differences in time period of venous thromboembolism ascertainment. At least 1 in 12 middle-aged adults will develop venous thromboembolism in their remaining lifetime. This estimate of lifetime risk may be useful to promote awareness of venous thromboembolism and guide decisions at both clinical and policy levels. Copyright © 2016 Elsevier Inc. All rights reserved.
Lang, Elvira V; Reyes, Jorge; Faintuch, Salomao; Smith, Amy; Abu-Elmagd, Kareem
2005-09-01
To assess feasibility and success of venous recanalization in patients with short gut syndrome who have lost their traditional central venous access and required intestinal or multivisceral transplantation. Twelve patients between the ages of 7 and 55 years with short gut syndrome and long-standing total parenteral nutrition (TPN) dependency and/or hypercoagulability were treated. All had extensive chronic central venous occlusions and survival was dependent on restoration of access and planned transplantation. Central venous recanalizations were obtained via sharp needle recanalization techniques, venous reconstructions with stents, and/or extraanatomic access to the central venous system for placement of central venous tunneled catheters. Central venous access was restored in all patients without operative-related mortality. Three major hemodynamic perioperative technical complications were recorded and successfully treated. There were three self-limited early infectious complications. With a mean follow-up of 22 months, eight of the 12 patients were alive with successful small bowel or multivisceral transplantation; six of those became independent of TPN. The remaining four patients died of complications related to TPN (n = 3) or transplantation (n = 1). With a mean follow-up of 20 months, all but two of the recanalized venous accesses were maintained, for a success rate of 83%. Recanalizations of extensive chronic vein occlusions are feasible but associated with high risk. The technique is life-saving for TPN-dependent patients and can restore candidacy for intestinal and multivisceral transplantation. This approach is likely to be increasingly requested because of the current clinical availability of the transplant procedure.
Lam, A; Fernando, D; Sirlin, C C; Nayyar, M; Goodwin, S C; Imagawa, D K; Lall, C
2017-11-01
To evaluate the utility of the portal venous phase on multiphasic computed tomography (CT) after treatment of hepatocellular carcinoma (HCC) with trans-arterial chemoembolisation (TACE). This was a retrospective review of patients who underwent TACE for HCC between 1 April 2012 and 21 December 2014, with appropriate multiphasic, pre- and post-procedural CT examinations. The maximum non-contrast, arterial phase, and portal venous phase attenuation values of the tumour and tumour bed were evaluated within a region of interest (ROI), with values adjusted against background hepatic parenchyma. Linear regression analyses were performed for both the arterial and venous phases, to assess the level of enhancement and to determine if the venous phase had additional value in this setting. A total of 86 cases from 51 patients were reviewed. All pre-procedural CT examinations of lesions demonstrated arterial phase enhancement with portal venous and delayed phase washout compatible with HCC. The post-procedural CT examinations following TACE revealed expected decreased arterial enhancement. Sixty-five cases (76%) showed persistent non-enhancement on the portal venous phase following embolisation therapy. A total of 21 cases (24%), however, demonstrated progressive portal venous hyper enhancement. Linear regression analysis demonstrated a statistical significance between the difference in maximal arterial and portal venous enhancement in these cases. Following TACE, the treated lesion may demonstrate portal venous phase hyper-enhancement within the tumour bed. As such, full attention should be given to these images for comprehensive evaluation of tumour response following treatment. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Risk factors for venous port migration in a single institute in Taiwan.
Fan, Wen-Chieh; Wu, Cheng-Han; Tsai, Ming-Ju; Tsai, Ying-Ming; Chang, Hsu-Liang; Hung, Jen-Yu; Chen, Pei-Huan; Yang, Chih-Jen
2014-01-14
An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor.
Chronic leg ulceration in homozygous sickle cell disease: the role of venous incompetence.
Clare, Andrea; FitzHenley, Michael; Harris, June; Hambleton, Ian; Serjeant, Graham R
2002-11-01
Chronic leg ulceration is a common cause of morbidity in Jamaican patients with homozygous sickle cell (SS) disease. Ulcers heal more rapidly on bed rest and deteriorate on prolonged standing, suggesting a role of venous hypertension in their persistence. This hypothesis has been tested by Doppler detection of venous competence in SS patients and in matched controls with a normal haemoglobin (AA) genotype in the Jamaican Cohort Study. Venous incompetence was significantly more frequent in SS disease [137/183 (75%)] than in non-pregnant AA controls [53/137 (39%)]. Past or present ulceration occurred in 78 (43%) SS patients, with a highly significant association between leg ulceration and venous incompetence in the same leg (P < 0.001). Prominence and/or varicosities of the veins and spontaneous leg ulcers were more common among patients with multiple sites of incompetence. The association of venous incompetence with chronic leg ulceration identifies a further pathological mechanism contributing to the morbidity of SS disease. The cause of venous incompetence is unknown but the sluggish circulation associated with dependency, turbidity and impaired linear flow at venous valves, hypoxia-induced sickling, the rheological effects of high white cell counts, and activation of components of the coagulation system may all contribute. Venous hypertension in SS patients with leg ulceration suggests that firm elastic supportive dressings might promote healing of chronic leg ulcers.
A 1D pulse wave propagation model of the hemodynamics of calf muscle pump function.
Keijsers, J M T; Leguy, C A D; Huberts, W; Narracott, A J; Rittweger, J; van de Vosse, F N
2015-07-01
The calf muscle pump is a mechanism which increases venous return and thereby compensates for the fluid shift towards the lower body during standing. During a muscle contraction, the embedded deep veins collapse and venous return increases. In the subsequent relaxation phase, muscle perfusion increases due to increased perfusion pressure, as the proximal venous valves temporarily reduce the distal venous pressure (shielding). The superficial and deep veins are connected via perforators, which contain valves allowing flow in the superficial-to-deep direction. The aim of this study is to investigate and quantify the physiological mechanisms of the calf muscle pump, including the effect of venous valves, hydrostatic pressure, and the superficial venous system. Using a one-dimensional pulse wave propagation model, a muscle contraction is simulated by increasing the extravascular pressure in the deep venous segments. The hemodynamics are studied in three different configurations: a single artery-vein configuration with and without valves and a more detailed configuration including a superficial vein. Proximal venous valves increase effective venous return by 53% by preventing reflux. Furthermore, the proximal valves shielding function increases perfusion following contraction. Finally, the superficial system aids in maintaining the perfusion during the contraction phase and reduces the refilling time by 37%. © 2015 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.
Portal hemodynamic responses after oral intake of glucose in patients with cirrhosis.
Tsunoda, T; Ohnishi, K; Tanaka, H
1988-04-01
Changes of portal, superior mesenteric, and splenic venous flows, and portohepatic gradient (portal vein pressure minus free hepatic vein pressure) after a meal were studied in patients with cirrhosis using the duplex ultrasonic Doppler flowmeter, and portal and hepatic vein catheterizations after ingestion of 227 ml of 33% glucose solution (300 kcal). As a control, changes of portal venous flow and portohepatic gradient after drinking 227 ml of water, were studied. Portal and superior mesenteric venous flows increased significantly at 30 min after glucose intake, and they returned gradually to the basal values, whereas no significant postprandial change occurred in splenic venous flow. The sum of superior mesenteric and splenic venous flows was greater than the estimated portal venous flow before glucose intake, and the difference widened during post-prandial mesenteric hyperemia, indicating an increase of blood flow into the portal-systemic shunts. After glucose intake, portohepatic gradient elevated immediately, in parallel with an increase of portal venous flow, and these changes persisted for the 30 min studied; however, no significant change occurred in these parameters after drinking water. 1) In patients with cirrhosis, hyperemia occurs in the intestine but not in the spleen after glucose intake, and 2) postprandial mesenteric hyperemia causes an increase of portal venous inflow, portal-systemic collateral flow, portal venous flow, and an elevation of portohepatic gradient.
2013-01-01
The extra-cranial venous system is complex and not well studied in comparison to the peripheral venous system. A newly proposed vascular condition, named chronic cerebrospinal venous insufficiency (CCSVI), described initially in patients with multiple sclerosis (MS) has triggered intense interest in better understanding of the role of extra-cranial venous anomalies and developmental variants. So far, there is no established diagnostic imaging modality, non-invasive or invasive, that can serve as the “gold standard” for detection of these venous anomalies. However, consensus guidelines and standardized imaging protocols are emerging. Most likely, a multimodal imaging approach will ultimately be the most comprehensive means for screening, diagnostic and monitoring purposes. Further research is needed to determine the spectrum of extra-cranial venous pathology and to compare the imaging findings with pathological examinations. The ability to define and reliably detect noninvasively these anomalies is an essential step toward establishing their incidence and prevalence. The role for these anomalies in causing significant hemodynamic consequences for the intra-cranial venous drainage in MS patients and other neurologic disorders, and in aging, remains unproven. PMID:23806142
Intravascular thrombosis as a result of central venous access.
Biernacka, Jadwiga; Nestorowicz, Andrzej; Wach, Małgorzata
2002-01-01
Central venous access represents one of the most basic therapeutic procedures in modern medicine. Unfortunately, numerous advantages that result from maintaining a central venous line are accompanied by some complications among which the venous thrombosis is the most significant clinically. The study was designed to assess frequency and natural history of this complication in the setting at a multi profile clinical hospital. Central venous cannulation was performed by a fully qualified anaesthesiologist in every case. There were 887 cannulations and only 5 patients with clinically significant venous thrombosis. The analysis of the collected data allowed us to state that the frequency of intravascular thrombosis is low, but this complication is often associated with extensive impairment of patency of the central veins. Full recanalization is not always achieved regardless of the treatment applied. Pulmonary embolism in the course of central venous thrombosis was diagnosed in one patient only and appeared as a multiple and fine X-ray infiltrates. It seems that in the presence of permanent or even life threatening complications of central venous thrombosis their risk should be minimized by frequent examination of the cannulation site and early initiation of antithrombotic treatment.
Emerging nutrition science on fatty acids and cardiovascular disease: nutritionists' perspectives.
Kris-Etherton, Penny M; Fleming, Jennifer A
2015-05-01
Recent dietary guidance for heart health recommends a reduction (by ∼50%) in saturated fatty acid (SFA) intake to reduce LDL cholesterol and to decrease risk of cardiovascular disease (CVD). The 2010 Dietary Guidelines for Americans recommends substituting unsaturated fat [both polyunsaturated and monounsaturated fatty acids (PUFAs and MUFAs, respectively)] for SFAs. There are many dietary options that can be implemented to replace SFAs, given the different sources of unsaturated fats in the food supply. Compelling evidence exists for the cardioprotective benefits of n-3 (ω-3) PUFAs, both marine- and plant-derived. In addition, the evidence of cardioprotective benefits of n-6 (ω-6) PUFAs is strong, whereas that for MUFAs is mixed, although there is emerging evidence of benefits. Quantitatively, lowering SFAs by 50% will require, in part, substituting food sources of n-6 and n-3 PUFAs and MUFAs for food sources of SFAs. The use of n-3 PUFAs as a replacement for SFAs will result in a shortfall in reaching the SFA goal because of the relatively low amounts that can be incorporated in the diet, even with very high n-3 PUFA substitution. SFAs also can be replaced with dietary carbohydrate and/or protein. Replacing SFAs with carbohydrate, specifically refined sources, however, has little impact on reducing CVD risk. There is evidence about the health benefits of dietary protein on CVD risk, which merits study. Dietary guidelines have advanced considerably with the "replacement of SFA with unsaturated fat message" instead of recommending decreasing SFAs alone. A key question that remains is what is the optimal mix of macronutrients to maximally reduce CVD risk. © 2015 American Society for Nutrition.
Burgess, Diana J; Fu, Steven S; Noorbaloochi, Siamak; Clothier, Barbara A; Ricards, Jennifer; Widome, Rachel; van Ryn, Michelle
2009-12-01
This study examines the presence and correlates of gender disparities in smoking cessation among lower income smokers prescribed nicotine replacement medication. We examined quit rates (7-day abstinence point prevalence) among a cohort of smokers who filled prescriptions for nicotine replacement (N = 1,782), using Minnesota Health Care Programs' (e.g., Medicaid) pharmacy claims databases (2005-2006) and mixed-mode survey protocols. A cohort of smokers who recently filled a prescription for nicotine replacement was stratified by race, and then subjects were selected by simple random sample from each race, oversampling the nonWhite groups (N = 1,782). The primary outcome was point prevalence of 7-day abstinence, and outcomes were assessed about 8 months after the nicotine replacement therapy (NRT) index prescription fill date using a mixed-mode survey protocol. Final interaction models were constructed using backward elimination. Abstinence rates were 11.4% among women and 19.2% among men (p = .02) and remained marginally significant after controlling for demographics, mental and physical health, period of cigarette abstinence, social environment, religious attendance, perceived stress, and NRT prescription type (p = .08). There was a significant Gender x Employment interaction (p = .02). Among men, quit rates were higher among the employed (26%) compared with the unemployed (16%); among women, quit rates were lower among those who were employed (8%) compared with those who were unemployed (14%). Results suggest the need for research on factors specific to women's work roles or workplaces that inhibit cessation as well as cessation programs tailored to low-income, employed female smokers. On-site workplace interventions and flexible counseling programs may be especially beneficial.
Nomura, Jason T; Sierzenski, Paul R; Nace, Jason E; Bollinger, Melissa
2008-07-01
Use of ultrasound guidance for Central Venous Catheter insertion has been associated with decreased complications and increased success rates. Previous reports show low rates of use among physicians. Evaluation of the frequency of Ultrasound Guidance use for Central Venous Catheter insertion among residents at a teaching institution. A cross sectional electronic survey of resident physicians at a tertiary care teaching hospital was conducted to evaluate use of Ultrasound Guidance for Central Venous Catheterization. Assessment included self reported frequency of ultrasound guidance use, and volume of central venous catheter placement. Attitudes toward the use of ultrasound were assessed using Likert scales. There is a high rate. over 90%, of ultrasound guidance use for Internal Jugular central venous catheters among residents. The majority of residents use sterile real-time imaging with a single operator with a reported success rate greater then 80%. Resident use of ultrasound guidance for Internal Jugular central venous catheter insertion can be much higher than previously reported in the literature.
Hybrid model of arm for analysis of regional blood oxygenation in non-invasive optical diagnostics
NASA Astrophysics Data System (ADS)
Nowocień, Sylwester; Mroczka, Janusz
2017-06-01
The paper presents a new comprehensive approach to modeling and analysis of processes occurring during the blood flow in the arm's small vessels as well as non-invasive measurement method of mixed venous oxygen saturation. During the work, a meta-analysis of available physiological data was performed and based on its result a hybrid model of forearm vascular tree was proposed. The model, in its structure, takes into account a classical nonlinear hydro-electric analogy in conjunction with light-tissue interaction. Several geometries of arm vascular tree obtained from magnetic resonance angiography (MRA) image were analyzed which allowed to proposed the structure of electrical analog network. Proposed model allows to simulate the behavior of forearm blood flow from the vascular tree mechanics point of view, as well as effects of the impact of cuff and vessel wall mechanics on the recorded photoplethysmographic signals. In particular, it allows to analyze the reaction and anatomical effects in small vessels and microcirculation caused by occlusive maneuver in selected techniques, what was of particular interest to authors and motivation to undertake research in this area. Preliminary studies using proposed model showed that inappropriate selection of occlusion maneuver parameters (e.g. occlusion time, cuff pressure etc.), cause dangerous turbulence of blood flow in the venous section of the vascular tree.
Induced Hypothermia Does Not Harm Hemodynamics after Polytrauma: A Porcine Model
Mommsen, Philipp; Pfeifer, Roman; Mohr, Juliane; Ruchholtz, Steffen; Flohé, Sascha; Fröhlich, Matthias; Keibl, Claudia; Seekamp, Andreas; Witte, Ingo
2015-01-01
Background. The deterioration of hemodynamics instantly endangers the patients' life after polytrauma. As accidental hypothermia frequently occurs in polytrauma, therapeutic hypothermia still displays an ambivalent role as the impact on the cardiopulmonary function is not yet fully understood. Methods. We have previously established a porcine polytrauma model including blunt chest trauma, penetrating abdominal trauma, and hemorrhagic shock. Therapeutic hypothermia (34°C) was induced for 3 hours. We documented cardiovascular parameters and basic respiratory parameters. Pigs were euthanized after 15.5 hours. Results. Our polytrauma porcine model displayed sufficient trauma impact. Resuscitation showed adequate restoration of hemodynamics. Induced hypothermia had neither harmful nor major positive effects on the animals' hemodynamics. Though heart rate significantly decreased and mixed venous oxygen saturation significantly increased during therapeutic hypothermia. Mean arterial blood pressure, central venous pressure, pulmonary arterial pressure, and wedge pressure showed no significant differences comparing normothermic trauma and hypothermic trauma pigs during hypothermia. Conclusions. Induced hypothermia after polytrauma is feasible. No major harmful effects on hemodynamics were observed. Therapeutic hypothermia revealed hints for tissue protective impact. But the chosen length for therapeutic hypothermia was too short. Nevertheless, therapeutic hypothermia might be a useful tool for intensive care after polytrauma. Future studies should extend therapeutic hypothermia. PMID:26170533
Mi, Zhibao; Novitzky, Dimitri; Collins, Joseph F; Cooper, David KC
2015-01-01
The management of brain-dead organ donors is complex. The use of inotropic agents and replacement of depleted hormones (hormonal replacement therapy) is crucial for successful multiple organ procurement, yet the optimal hormonal replacement has not been identified, and the statistical adjustment to determine the best selection is not trivial. Traditional pair-wise comparisons between every pair of treatments, and multiple comparisons to all (MCA), are statistically conservative. Hsu’s multiple comparisons with the best (MCB) – adapted from the Dunnett’s multiple comparisons with control (MCC) – has been used for selecting the best treatment based on continuous variables. We selected the best hormonal replacement modality for successful multiple organ procurement using a two-step approach. First, we estimated the predicted margins by constructing generalized linear models (GLM) or generalized linear mixed models (GLMM), and then we applied the multiple comparison methods to identify the best hormonal replacement modality given that the testing of hormonal replacement modalities is independent. Based on 10-year data from the United Network for Organ Sharing (UNOS), among 16 hormonal replacement modalities, and using the 95% simultaneous confidence intervals, we found that the combination of thyroid hormone, a corticosteroid, antidiuretic hormone, and insulin was the best modality for multiple organ procurement for transplantation. PMID:25565890
Turkoz, Riza; Ayabakan, Canan; Vuran, Can; Omay, Oğuz
2010-08-01
A 7-month-old boy with heterotaxy syndrome had partial atrioventricular septal defect and interrupted inferior vena cava with hemiazygos continuation to a left superior vena cava. The left side of the common atrium receiving all the venous drainage was in connection with the left ventricle and the aorta. The small atrium and the proximity of the pulmonary and hepatic vein orifices precluded complete baffling. This report describes an intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage. This resulted in good oxygenation postoperatively, with oxygen saturation ranging from 93% to 98%.
75 FR 49029 - Medicare Program; End-Stage Renal Disease Prospective Payment System
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-12
...This final rule implements a case-mix adjusted bundled prospective payment system (PPS) for Medicare outpatient end-stage renal disease (ESRD) dialysis facilities beginning January 1, 2011 (ESRD PPS), in compliance with the statutory requirement of the Medicare Improvements for Patients and Providers Act (MIPPA), enacted July 15, 2008. This ESRD PPS also replaces the current basic case-mix adjusted composite payment system and the methodologies for the reimbursement of separately billable outpatient ESRD services.
Venous thrombosis and stenosis after peripherally inserted central catheter placement in children.
Shin, H Stella; Towbin, Alexander J; Zhang, Bin; Johnson, Neil D; Goldstein, Stuart L
2017-11-01
Peripherally inserted central catheters (PICCs) can lead to development of venous thrombosis and/or stenosis. The presence of venous thrombosis and/or stenosis may preclude children with chronic medical conditions from receiving lifesaving therapies, from hemodialysis in end-stage renal disease to total parenteral nutrition in short bowel syndrome. Several adult studies have found an association between PICCs and venous thrombosis and/or stenosis, but none has evaluated for this association in children. To determine the incidence of venous thrombosis and/or stenosis after PICC placement and identify factors that increase the risk of venous thrombosis and/or stenosis after PICC placement in children. We conducted a retrospective review of children ages 1-18 years with a PICC placed between January 2010 and July 2013 at our center, and included those who had at least one vascular imaging study of the ipsilateral extremity (Doppler ultrasound, venogram or MR angiogram) after PICC placement. Logistic regression was applied to determine risk factors for development of venous thrombosis and/or stenosis. One thousand, one hundred and ten upper extremity PICCs were placed, with 703 PICCs in the right and 407 PICCs in the left. Eight hundred fifty-one imaging studies (609 Doppler ultrasounds, 193 contrast venograms and 49 MR angiograms) were performed in 376 patients. The incidence of venous thrombosis and/or stenosis in the imaged cohort was 26.3%. PICC laterality, insertion site, duration, patient height to PICC diameter ratio, and number of PICCs per patient were not associated with development of venous thrombosis and/or stenosis. Additionally, primary diagnosis and symptoms at the time of imaging did not predict findings of venous thrombosis and/or stenosis. However, patients exposed to non-PICC central venous catheters (CVC) were more likely to develop venous thrombosis and/or stenosis (odds ratio 1.95, 1.10-3.45). More than a quarter of the vascular imaging studies performed in this study cohort showed previously unknown venous thrombosis and/or stenosis, irrespective of PICC laterality, insertion site, duration and size and the number of PICCs. A history of CVC was associated with a nearly two-fold increase in risk of venous thrombosis and/or stenosis after PICC placement. We suggest that PICCs and CVCs should be placed judiciously in all children, but especially in those with lifelong medical conditions who are more likely to incur direct consequences from limited vascular access.
Bertevello, Pedro L; De Nardi, Leticia; Torrinhas, Raquel S; Logullo, Angela F; Waitzberg, Dan L
2012-07-01
Soybean oil is rich in ω-6 fatty acids, which are associated with higher incidence and more severe cases of inflammatory bowel diseases. The authors evaluated whether partial replacement of soybean oil by medium-chain triglycerides (MCTs) or olive oil influenced the incidence and severity of experimental ulcerative colitis by using different parenteral lipid emulsions (LEs). Wistar rats (n = 40) were randomized to receive parenteral infusion of the following LE: 100% soybean oil (SO), 50% MCT mixed with 50% soybean oil (MCT/SO), 80% olive oil mixed with 20% soybean oil (OO/SO), or saline (CC). After 72 hours of infusion, acetic acid experimental colitis was induced. After 24 hours, colon histology and cytokine expression were analyzed. SO was not significantly associated with overall tissue damage. MCT/SO was not associated with necrosis (P < .005), whereas OO/SO had higher frequencies of ulcer and necrosis (P < .005). SO was associated with increased expression of interferon-γ (P = .005) and OO/SO with increased interleukin (IL)-6 and decreased tumor necrosis factor-α expression (P < .05). MCT/SO appeared to decrease IL-1 (P < .05) and increase IL-4 (P < .001) expression. Parenteral SO with high concentration of ω-6 fatty acids was not associated with greater tissue damage in experimental colitis. SO partial replacement with MCT/SO decreased the frequency of histological necrosis and favorably modulated cytokine expression in the colon; however, replacement with OO/SO had unfavorable effects.
Internal friction and vulnerability of mixed alkali glasses.
Peibst, Robby; Schott, Stephan; Maass, Philipp
2005-09-09
Based on a hopping model we show how the mixed alkali effect in glasses can be understood if only a small fraction c(V) of the available sites for the mobile ions is vacant. In particular, we reproduce the peculiar behavior of the internal friction and the steep fall ("vulnerability") of the mobility of the majority ion upon small replacements by the minority ion. The single and mixed alkali internal friction peaks are caused by ion-vacancy and ion-ion exchange processes. If c(V) is small, they can become comparable in height even at small mixing ratios. The large vulnerability is explained by a trapping of vacancies induced by the minority ions. Reasonable choices of model parameters yield typical behaviors found in experiments.
US Army Institute of Surgical Research Annual Research Progress Report for Fiscal Year 1987.
1987-10-01
oases, respiratory rate, chest roentgenograms), cardiovascular (blood pressure, central venous pressure, cardiac output), and renal (urine output, urine...Monitoring includes the precordial and/or esophageal stethoscope, peripheral pulse, blood pressure, central venous pressure, Swan-Ganz catheter... central venous , peripheral venous , and Swan-Ganz (7F, American Edward Laboratories, Irvine CA) catheters and an esophageal balloon were inserted. After a 2
Advanced Technologies in Trauma Critical Care Management
2012-01-01
CVL, central venous line; DVT, deep venous thrombosis; FAST, focused assessment with sonography for trauma; IVC, inferior vena cava; PIV, peripheral...either for a 1-time view of the target vein or in real time using a 1- or 2-person technique. Recently, ultrasound-guided subclavian central venous ...technologies such as bedside echocardiography, central venous pressure monitoring, and cardiac electrical velocimetry. These limitations aside, it is
Venous trauma in the Lebanon War--2006.
Nitecki, Samy S; Karram, Tony; Hoffman, Aaron; Bass, Arie
2007-10-01
Reports on venous trauma are relatively sparse. Severe venous trauma is manifested by hemorrhage, not ischemia. Bleeding may be internal or external and rarely may lead to hypovolemic shock. Repair of major extremity veins has been a subject of controversy and the current teaching is to avoid venous repair in an unstable or multi-trauma patient. The aim of the current paper is to present our recent experience in major venous trauma during the Lebanon conflict, means of diagnosis and treatment in a level I trauma center. All cases of major venous trauma, either isolated or combined with arterial injury, admitted to the emergency room during the 33-day conflict were reviewed. Out of 511 wounded soldiers and civilians who were admitted to our service over this period, 12 (2.3%) sustained a penetrating venous injury either isolated (5) or combined with arterial injury (7). All injuries were secondary to high velocity penetrating missiles or from multiple pellets stored in long-range missiles. All injuries were accompanied by additional insult to soft tissue, bone and viscera. The mean injury severity score was 15. Severe external bleeding was the presenting symptom in three cases of isolated venous injury (jugular, popliteal and femoral). The diagnosis of a major venous injury was made by a CTA scan in five cases, angiography in one and during surgical exploration in six cases. All injured veins were repaired: three by venous interposition grafts, four by end to end anastomosis, three by lateral suture and two by endovascular techniques. None of the injuries was treated by ligation of a major named vein. Immediate postoperative course was uneventful in all patients and the 30-day follow-up (by clinical assessment and duplex scan) has demonstrated a patent repair with no evidence of thrombosis. Without contradicting the wisdom of ligating major veins in the setup of multi-trauma or an unstable patient, our experience indicates that a routine repair of venous trauma can be safely and effectively performed in young patients. Postoperative course is not compromised and late sequelae of venous interruption may be prevented.
Placental Glucose Transfer: A Human In Vivo Study
Holme, Ane M.; Roland, Marie Cecilie P.; Lorentzen, Bjørg; Michelsen, Trond M.; Henriksen, Tore
2015-01-01
Objectives The placental transfer of nutrients is influenced by maternal metabolic state, placenta function and fetal demands. Human in vivo studies of this interplay are scarce and challenging. We aimed to establish a method to study placental nutrient transfer in humans. Focusing on glucose, we tested a hypothesis that maternal glucose concentrations and uteroplacental arterio-venous difference (reflecting maternal supply) determines the fetal venous-arterial glucose difference (reflecting fetal consumption). Methods Cross-sectional in vivo study of 40 healthy women with uncomplicated term pregnancies undergoing planned caesarean section. Glucose and insulin were measured in plasma from maternal and fetal sides of the placenta, at the incoming (radial artery and umbilical vein) and outgoing vessels (uterine vein and umbilical artery). Results There were significant mean (SD) uteroplacental arterio-venous 0.29 (0.23) mmol/L and fetal venous-arterial 0.38 (0.31) mmol/L glucose differences. The transplacental maternal-fetal glucose gradient was 1.22 (0.42) mmol/L. The maternal arterial glucose concentration was correlated to the fetal venous glucose concentration (r = 0.86, p<0.001), but not to the fetal venous-arterial glucose difference. The uteroplacental arterio-venous glucose difference was neither correlated to the level of glucose in the umbilical vein, nor fetal venous-arterial glucose difference. The maternal-fetal gradient was correlated to fetal venous-arterial glucose difference (r = 0.8, p<0.001) and the glucose concentration in the umbilical artery (r = −0.45, p = 0.004). Glucose and insulin concentrations were correlated in the mother (r = 0.52, p = 0.001), but not significantly in the fetus. We found no significant correlation between maternal and fetal insulin values. Conclusions We did not find a relation between indicators of maternal glucose supply and the fetal venous-arterial glucose difference. Our findings indicate that the maternal-fetal glucose gradient is significantly influenced by the fetal venous-arterial difference and not merely dependent on maternal glucose concentration or the arterio-venous difference on the maternal side of the placenta. PMID:25680194
Upper extremity deep venous thrombosis after port insertion: What are the risk factors?
Tabatabaie, Omidreza; Kasumova, Gyulnara G; Kent, Tara S; Eskander, Mariam F; Fadayomi, Ayotunde B; Ng, Sing Chau; Critchlow, Jonathan F; Tawa, Nicholas E; Tseng, Jennifer F
2017-08-01
Totally implantable venous access devices (ports) are widely used, especially for cancer chemotherapy. Although their use has been associated with upper extremity deep venous thrombosis, the risk factors of upper extremity deep venous thrombosis in patients with a port are not studied adequately. The Healthcare Cost and Utilization Project's Florida State Ambulatory Surgery and Services Database was queried between 2007 and 2011 for patients who underwent outpatient port insertion, identified by Current Procedural Terminology code. Patients were followed in the State Ambulatory Surgery and Services Database, State Inpatient Database, and State Emergency Department Database for upper extremity deep venous thrombosis occurrence. The cohort was divided into a test cohort and a validation cohort based on the year of port placement. A multivariable logistic regression model was developed to identify risk factors for upper extremity deep venous thrombosis in patients with a port. The model then was tested on the validation cohort. Of the 51,049 patients in the derivation cohort, 926 (1.81%) developed an upper extremity deep venous thrombosis. On multivariate analysis, independently significant predictors of upper extremity deep venous thrombosis included age <65 years (odds ratio = 1.22), Elixhauser score of 1 to 2 compared with zero (odds ratio = 1.17), end-stage renal disease (versus no kidney disease; odds ratio = 2.63), history of any deep venous thrombosis (odds ratio = 1.77), all-cause 30-day revisit (odds ratio = 2.36), African American race (versus white; odds ratio = 1.86), and other nonwhite races (odds ratio = 1.35). Additionally, compared with genitourinary malignancies, patients with gastrointestinal (odds ratio = 1.55), metastatic (odds ratio = 1.76), and lung cancers (odds ratio = 1.68) had greater risks of developing an upper extremity deep venous thrombosis. This study identified major risk factors of upper extremity deep venous thrombosis. Further studies are needed to evaluate the appropriateness of thromboprophylaxis in patients at greater risk of upper extremity deep venous thrombosis. Copyright © 2017 Elsevier Inc. All rights reserved.
[The unnecessary application of central venous catheterization in surgical patients].
Uemura, Keiko; Inoue, Satoki; Kawaguchi, Masahiko
2018-04-06
Perioperative physicians occasionally encounter situations where central venous catheters placed preoperatively turn out to be unnecessary. The purpose of this retrospective study is to identify the unnecessary application of central venous catheter placement and determine the factors associated with the unnecessary application of central venous catheter placement. Using data from institutional perioperative central venous catheter surveillance, we analysed data from 1,141 patients who underwent central venous catheter placement. We reviewed the central venous catheter registry and medical charts and allocated registered patients into those with the proper or with unnecessary application of central venous catheter according to standard indications. Multivariate analysis was used to identify factors associated with the unnecessary application of central venous catheter placement. In 107 patients, representing 9.38% of the overall population, we identified the unnecessary application of central venous catheter placement. Multivariate analysis identified emergencies at night or on holidays (odds ratio [OR] 2.109, 95% confidence interval [95% CI] 1.021-4.359), low surgical risk (OR=1.729, 95% CI 1.038-2.881), short duration of anesthesia (OR=0.961/10min increase, 95% CI 0.945-0.979), and postoperative care outside of the intensive care unit (OR=2.197, 95% CI 1.402-3.441) all to be independently associated with the unnecessary application of catheterization. Complications related to central venous catheter placement when the procedure consequently turned out to be unnecessary were frequently observed (9/107) compared with when the procedure was necessary (40/1034) (p=0.032, OR=2.282, 95% CI 1.076-4.842). However, the subsequent multivariate logistic model did not hold this significant difference (p=0.0536, OR=2.115, 95% CI 0.988-4.526). More careful consideration for the application of central venous catheter is required in cases of emergency surgery at night or on holidays, during low risk surgery, with a short duration of anesthesia, or in cases that do not require postoperative intensive care. Copyright © 2018 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
INTERIOR VIEW OF MIXER LOCATED ON SECOND FLOOR OF BATCH ...
INTERIOR VIEW OF MIXER LOCATED ON SECOND FLOOR OF BATCH PLANT. RECENTLY PURCHASED TO REPLACE OLD MIXER. USED TO MIX THE BATCH - Chambers-McKee Window Glass Company, Batch Plant, Clay Avenue Extension, Jeannette, Westmoreland County, PA
Worni, Mathias; Pietrobon, Ricardo; Zammar, Guilherme Roberto; Shah, Jatin; Yoo, Bryan; Maldonato, Mauro; Takemoto, Steven; Vail, Thomas P
2012-01-01
The Hospital Acquired Condition Strategy (HACS) denies payment for venous thromboembolism (VTE) after total knee arthroplasty (TKA). The intention is to reduce complications and associated costs, while improving the quality of care by mandating VTE prophylaxis. We applied a system dynamics model to estimate the impact of HACS on VTE rates, and potential unintended consequences such as increased rates of bleeding and infection and decreased access for patients who might benefit from TKA. The system dynamics model uses a series of patient stocks including the number needing TKA, deemed ineligible, receiving TKA, and harmed due to surgical complication. The flow of patients between stocks is determined by a series of causal elements such as rates of exclusion, surgery and complications. The number of patients harmed due to VTE, bleeding or exclusion were modeled by year by comparing patient stocks that results in scenarios with and without HACS. The percentage of TKA patients experiencing VTE decreased approximately 3-fold with HACS. This decrease in VTE was offset by an increased rate of bleeding and infection. Moreover, results from the model suggest HACS could exclude 1.5% or half a million patients who might benefit from knee replacement through 2020. System dynamics modeling indicates HACS will have the intended consequence of reducing VTE rates. However, an unintended consequence of the policy might be increased potential harm resulting from over administration of prophylaxis, as well as exclusion of a large population of patients who might benefit from TKA.
Factor XI and Contact Activation as Targets for Antithrombotic Therapy
Gailani, David; Bane, Charles E.; Gruber, Andras
2015-01-01
Summary The most commonly used anticoagulants produce therapeutic antithrombotic effects either by inhibiting thrombin or factor Xa, or by lowering the plasma levels of the precursors of these key enzymes, prothrombin and factor X. These drugs do not distinguish between thrombin generation contributing to thrombosis from thrombin generation required for hemostasis. Thus, anticoagulants increase bleeding risk, and many patients who would benefit from therapy go untreated because of comorbidities that place them at unacceptable risk for hemorrhage. Studies in animals demonstrate that components of the plasma contact activation system contribute to experimentally-induced thrombosis, despite playing little or no role in hemostasis. Attention has focused on factor XII, the zymogen of a protease (factor XIIa) that initiates contact activation when blood is exposed to foreign surfaces; and factor XI, the zymogen of the protease factor XIa, which links contact activation to the thrombin generation mechanism. In the case of factor XI, epidemiologic data indicate this protein contributes to stroke and venous thromboembolism, and perhaps myocardial infarction, in humans. A phase 2 trial showing that reduction of factor XI may be more effective than low-molecular-weight heparin at preventing venous thrombosis during knee replacement surgery provides proof of concept for the premise that an antithrombotic effect can be uncoupled from an anticoagulant effect in humans by targeting components of contact activation. Here we review data on the role of factor XI and factor XII in thrombosis, and results of pre-clinical and human trials for therapies targeting these proteins. PMID:25976012
Mahan, Charles E
2015-04-01
Target specific anticoagulants (TSOACs) have recently been introduced to the US market for multiple indications including venous thromboembolism (VTE) prevention in total hip and knee replacement surgeries, VTE treatment and reduction in the risk of stroke in patients with non-valvular atrial fibrillation (NVAF). Currently, three TSOACs are available including rivaroxaban, apixaban, and dabigatran with edoxaban currently under Food and Drug Administration review for VTE treatment and stroke prevention in NVAF. The introduction of these agents has created a paradigm shift in anticoagulation by considerably simplifying treatment and anticoagulant initiation for patients by giving clinicians the opportunity to use a rapid onset, rapid offset, oral agent. The availability of these rapid onset TSOACs is allowing for outpatient treatment of low risk pulmonary embolism and deep vein thrombosis which can greatly reduce healthcare costs by avoiding inpatient hospitalizations and treatment for the disease. Additionally with this practice, the complications of an inpatient hospitalization may also be avoided such as nosocomial infections. Single-agent approaches with TSOACs represent a paradigm shift in the treatment of VTE versus the complicated overlap of a parenteral agent with warfarin. Transitions between anticoagulants, including TSOACs, are a high-risk period for the patient, and clinicians must carefully consider patient characteristics such as renal function as well as the agents that are being transitioned. TSOAC use appears to be growing slowly with improved payment coverage throughout the US.
[Perioperative acute kidney injury and failure].
Chhor, Vibol; Journois, Didier
2014-04-01
Perioperative period is very likely to lead to acute renal failure because of anesthesia (general or perimedullary) and/or surgery which can cause acute kidney injury. Characterization of acute renal failure is based on serum creatinine level which is imprecise during and following surgery. Studies are based on various definitions of acute renal failure with different thresholds which skewed their comparisons. The RIFLE classification (risk, injury, failure, loss, end stage kidney disease) allows clinicians to distinguish in a similar manner between different stages of acute kidney injury rather than using a unique definition of acute renal failure. Acute renal failure during the perioperative period can mainly be explained by iatrogenic, hemodynamic or surgical causes and can result in an increased morbi-mortality. Prevention of this complication requires hemodynamic optimization (venous return, cardiac output, vascular resistance), discontinuation of nephrotoxic drugs but also knowledge of the different steps of the surgery to avoid further degradation of renal perfusion. Diuretics do not prevent acute renal failure and may even push it forward especially during the perioperative period when venous retourn is already reduced. Edema or weight gain following surgery are not correlated with the vascular compartment volume, much less with renal perfusion. Treatment of perioperative acute renal failure is similar to other acute renal failure. Renal replacement therapy must be mastered to prevent any additional risk of hemodynamic instability or hydro-electrolytic imbalance. Copyright © 2014 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.
Bilateral Total Hip Arthroplasty: 1-Stage or 2-Stage? A Meta-Analysis.
Shao, Hongyi; Chen, Chi-Lung; Maltenfort, Mitchell G; Restrepo, Camilo; Rothman, Richard H; Chen, Antonia F
2017-02-01
Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed in the last 50 years. However, controversies still exist between conducting 1- or 2-stage bilateral THA. Using PubMed, Ovid, Embase, and Cochrane library databases, we searched for papers written between January 1995 and October 2015 that contained the following search terms: "one-stage or two-stage" or "simultaneous or staged," and "hip" and "arthroplasty or replacement." A meta-analysis was conducted with the collected pooled data about major and minor systemic complications, surgical complications, and other perioperative data associated with 1- and 2-stage bilateral THA. Statistical analysis was performed by the Mantel-Haenszel method, and the fixed effect model was used to analyze data. There were 13 studies with 17,762 patients who underwent 1-stage bilateral THA and 46,147 patients who underwent 2-stage bilateral THA. One-stage bilateral THA had a lower risk of major systemic complications, less deep venous thrombosis, and shorter operative time compared with 2-stage bilateral THA. There were no significant differences in death, pulmonary embolism, cardiovascular complication, infections, minor complications, and other surgical complications between procedures. One-stage bilateral THA was superior to 2-stage bilateral THA in terms of major systemic complication, deep venous thrombosis, and surgical time compared with 2-stage bilateral THA. However, this study does not encourage performing 1-stage over 2-stage bilateral THA. Higher evidence level studies are necessary for further analysis. Copyright © 2016 Elsevier Inc. All rights reserved.
Adrenal haemorrhage due to heparin-induced thrombocytopenia.
Ketha, Siva; Smithedajkul, Patrick; Vella, Adrian; Pruthi, Rajiv; Wysokinski, Waldemar; McBane, Robert
2013-04-01
Adrenal haemorrhage (AH) is a rare but potentially devastating complication of heparin-induced thrombocytopenia (HIT). Neither the prevalence nor the natural history of AH due to HIT are known. The objectives of this study were to identify the spectrum of AH causes, to characterise the frequency of AH due to HIT and determine the natural history of HIT-associated AH. All patients with incident adrenal haemorrhage from January 2002 through June 2012 seen at the Mayo Clinic were identified. Over this time frame, there were a total of 115 patients with AH of which 11 cases (10%; mean age 67 ± 8 years; 73% female) were associated with HIT. Of these, all but one occurred in the postoperative setting and involved both adrenal glands (89%) with acute adrenal insufficiency at the time of diagnosis. Cases were found incidentally during an evaluation for fever, shock, abdominal pain or mental status changes. All HIT patients experienced venous thrombosis at other locations including deep venous thromboses (n=14), pulmonary emboli (n= 4) and arterial thrombosis (n=2). Four patients undergoing total knee arthroplasty had "spontaneous HIT" with AH in the absence of identifiable heparin exposure. Other causes of AH included trauma (29%), sepsis (15%), antiphospholipid antibody syndrome (10%), and metastatic disease (12%). In conclusion, AH is an important but seldom recognised presumed thrombotic complication of HIT, which usually occurs in the postoperative period, especially after orthopaedic procedures. This syndrome can occur in the apparent absence of heparin exposure, especially following major joint replacement surgery.
Crystalloids versus colloids for goal-directed fluid therapy in major surgery
Hiltebrand, Luzius B; Kimberger, Oliver; Arnberger, Michael; Brandt, Sebastian; Kurz, Andrea; Sigurdsson, Gisli H
2009-01-01
Introduction Perioperative hypovolemia arises frequently and contributes to intestinal hypoperfusion and subsequent postoperative complications. Goal-directed fluid therapy might reduce these complications. The aim of this study was to compare the effects of goal-directed administration of crystalloids and colloids on the distribution of systemic, hepatosplanchnic, and microcirculatory (small intestine) blood flow after major abdominal surgery in a clinically relevant pig model. Methods Twenty-seven pigs were anesthetized and mechanically ventilated and underwent open laparotomy. They were randomly assigned to one of three treatment groups: the restricted Ringer lactate (R-RL) group (n = 9) received 3 mL/kg per hour of RL, the goal-directed RL (GD-RL) group (n = 9) received 3 mL/kg per hour of RL and intermittent boluses of 250 mL of RL, and the goal-directed colloid (GD-C) group (n = 9) received 3 mL/kg per hour of RL and boluses of 250 mL of 6% hydroxyethyl starch (130/0.4). The latter two groups received a bolus infusion when mixed venous oxygen saturation was below 60% ('lockout' time of 30 minutes). Regional blood flow was measured in the superior mesenteric artery and the celiac trunk. In the small bowel, microcirculatory blood flow was measured using laser Doppler flowmetry. Intestinal tissue oxygen tension was measured with intramural Clark-type electrodes. Results After 4 hours of treatment, arterial blood pressure, cardiac output, mesenteric artery flow, and mixed oxygen saturation were significantly higher in the GD-C and GD-RL groups than in the R-RL group. Microcirculatory flow in the intestinal mucosa increased by 50% in the GD-C group but remained unchanged in the other two groups. Likewise, tissue oxygen tension in the intestine increased by 30% in the GD-C group but remained unchanged in the GD-RL group and decreased by 18% in the R-RL group. Mesenteric venous glucose concentrations were higher and lactate levels were lower in the GD-C group compared with the two crystalloid groups. Conclusions Goal-directed colloid administration markedly increased microcirculatory blood flow in the small intestine and intestinal tissue oxygen tension after abdominal surgery. In contrast, goal-directed crystalloid and restricted crystalloid administrations had no such effects. Additionally, mesenteric venous glucose and lactate concentrations suggest that intestinal cellular substrate levels were higher in the colloid-treated than in the crystalloid-treated animals. These results support the notion that perioperative goal-directed therapy with colloids might be beneficial during major abdominal surgery. PMID:19302713
Leaching of heavy metals from solidified waste using Portland cement and zeolite as a binder.
Napia, Chuwit; Sinsiri, Theerawat; Jaturapitakkul, Chai; Chindaprasirt, Prinya
2012-07-01
This study investigated the properties of solidified waste using ordinary Portland cement (OPC) containing synthesized zeolite (SZ) and natural zeolite (NZ) as a binder. Natural and synthesized zeolites were used to partially replace the OPC at rates of 0%, 20%, and 40% by weight of the binder. Plating sludge was used as contaminated waste to replace the binder at rates of 40%, 50% and 60% by weight. A water to binder (w/b) ratio of 0.40 was used for all of the mixtures. The setting time and compressive strength of the solidified waste were investigated, while the leachability of the heavy metals was determined by TCLP. Additionally, XRD, XRF, and SEM were performed to investigate the fracture surface, while the pore size distribution was analyzed with MIP. The results indicated that the setting time of the binders marginally increased as the amount of SZ and NZ increased in the mix. The compressive strengths of the pastes containing 20 and 40wt.% of NZ were higher than those containing SZ. The compressive strengths at 28 days of the SZ solidified waste mixes were 1.2-31.1MPa and those of NZ solidified waste mixes were 26.0-62.4MPa as compared to 72.9MPa of the control mix at the same age. The quality of the solidified waste containing zeolites was better than that with OPC alone in terms of the effectiveness in reducing the leachability. The concentrations of heavy metals in the leachates were within the limits specified by the US EPA. SEM and MIP revealed that the replacement of Portland cement by zeolites increased the total porosity but decreased the average pore size and resulted in the better containment of heavy ions from the solidified waste. Copyright © 2012 Elsevier Ltd. All rights reserved.
Reuse of waste iron as a partial replacement of sand in concrete.
Ismail, Zainab Z; Al-Hashmi, Enas A
2008-11-01
One of the major environmental issues in Iraq is the large quantity of waste iron resulting from the industrial sector which is deposited in domestic waste and in landfills. A series of 109 experiments and 586 tests were carried out in this study to examine the feasibility of reusing this waste iron in concrete. Overall, 130 kg of waste iron were reused to partially replace sand at 10%, 15%, and 20% in a total of 1703 kg concrete mixtures. The tests performed to evaluate waste-iron concrete quality included slump, fresh density, dry density, compressive strength, and flexural strength tests: 115 cubes of concrete were molded for the compressive strength and dry density tests, and 87 prisms were cast for the flexural strength tests. This work applied 3, 7, 14, and 28 days curing ages for the concrete mixes. The results confirm that reuse of solid waste material offers an approach to solving the pollution problems that arise from an accumulation of waste in a production site; in the meantime modified properties are added to the concrete. The results show that the concrete mixes made with waste iron had higher compressive strengths and flexural strengths than the plain concrete mixes.
Bordes, Brianne M; Walia, Hina; Sebastian, Roby; Martin, David; Tumin, Dmitry; Tobias, Joseph D
2017-12-01
Lactic acid and base deficit (BD) values are frequently monitored in the intensive care unit and operating room setting to evaluate oxygenation, ventilation, cardiac output, and peripheral perfusion. Although generally obtained from an arterial cannula, such access may not always be available. The current study prospectively investigates the correlation of arterial and peripheral venous values of BD and lactic acid. The study cohort included 48 patients. Arterial BD values ranged from -8 to 4 mEq/L and peripheral venous BD values ranged from -8 to 4 mEq/L. Arterial lactic acid values ranged from 0.36 to 2.45 μmol/L and peripheral venous lactic acid values ranged from 0.38 to 4 μmol/L. The arterial BD (-0.4 ± 2.2 mEq/L) was not significantly different from the peripheral venous BD (-0.6 ± 2.2 mEq/L). The arterial lactic acid (1.0 ± 0.5 μmol/L) was not significantly different from the peripheral venous lactic acid (1.1 ± 0.6 μmol/L). Pearson correlation coefficients demonstrated a very high correlation between arterial and peripheral venous BD ( r = .88, P < .001) and between arterial and peripheral venous lactic acid ( r = .67, P < .001). Bland-Altman plots of both pairs of measures showed that the majority of observations fell within the 95% limits of agreement. Least-squares regression indicated that a 1-unit increase in arterial BD corresponded to a 0.9-unit increase in peripheral venous BD (95% confidence interval [CI]: 0.7-1.0; P < .001) and a 1-unit increase in arterial lactic acid corresponded to a 0.9-unit increase in peripheral venous lactic acid (95% CI: 0.6-1.2; P < .001). These data demonstrate that there is a clinically useful correlation between arterial and peripheral venous lactic acid and BD values.
Bohnhoff, James C.; DiSilvio, Stefanie A.; Aneja, Rajesh K.; Shenk, Jennifer R.; Domnina, Yuliya A.; Brozanski, Beverly S.; Good, Misty
2016-01-01
Objective The critically ill, premature patients of neonatal intensive care units are susceptible to venous thrombosis, an adverse event associated with short- and long-term morbidity. Venous thrombosis is frequently treated with low molecular weight heparins (LMWH) such as enoxaparin, but optimal dosing of LMWH must balance the morbidity of venous thrombosis with the potential adverse affects of anticoagulation. The optimal dosing of enoxaparin for premature infants is unclear. The objective of this study was to describe enoxaparin therapy and follow-up in critically ill neonates diagnosed with venous thrombosis. Study Design Retrospective medical record review in the neonatal intensive care unit (NICU) in a single tertiary care institution. Infants with venous thrombosis diagnosed in the NICU were identified using pre-existing quality improvement lists and medical records. Results Twenty-six infants with 30 venous thromboses were identified with a median gestational age of 31 weeks at birth. Eighteen (69%) infants received enoxaparin for venous thrombosis during their hospitalization, beginning with a median dose of 1.5 mg/kg every 12h. This dose was increased to a median 2.1 mg/kg every 12h to achieve target anti-factor Xa levels. The target dose was significantly higher in patients with a postmenstrual age less than 37 weeks. Enoxaparin treatment was documented after discharge in 12 patients, continuing for a median of 99 days. Four patients died during hospitalization and their deaths were not attributable to venous thrombosis or anticoagulation complication. Follow-up documentation between 6 and 24 months after venous thrombosis diagnosis revealed no major morbidity of venous thrombosis or enoxaparin therapy. Conclusions Our data reinforces the relative safety and necessity of enoxaparin doses above 1.5 mg/kg per 12 hours in most neonates. This was particularly true for infants at lower postmenstrual age. PMID:27906197
Vacuum-assisted venous return reduces blood usage.
Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M
2003-09-01
To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased red cell and total blood product usage.
Properties of Cement Mortar Produced from Mixed Waste Materials with Pozzolanic Characteristics.
Yen, Chi-Liang; Tseng, Dyi-Hwa; Wu, Yue-Ze
2012-07-01
Waste materials with pozzolanic characteristics, such as sewage sludge ash (SSA), coal combustion fly ash (FA), and granulated blast furnace slag (GBS), were reused as partial cement replacements for making cement mortar in this study. Experimental results revealed that with dual replacement of cement by SSA and GBS and triple replacement by SSA, FA, and GBS at 50% of total cement replacement, the compressive strength (Sc) of the blended cement mortars at 56 days was 93.7% and 92.9% of the control cement mortar, respectively. GBS had the highest strength activity index value and could produce large amounts of CaO to enhance the pozzolanic activity of SSA/FA and form calcium silicate hydrate gels to fill the capillary pores of the cement mortar. Consequently, the Sc development of cement mortar with GBS replacement was better than that without GBS, and the total pore volume of blended cement mortars with GBS/SSA replacement was less than that with FA/SSA replacement. In the cement mortar with modified SSA and GBS at 70% of total cement replacement, the Sc at 56 days was 92.4% of the control mortar. Modifying the content of calcium in SSA also increased its pozzolanic reaction. CaCl(2) accelerated the pozzolanic activity of SSA better than lime did. Moreover, blending cement mortars with GBS/SSA replacement could generate more monosulfoaluminate to fill capillary pores.
Properties of Cement Mortar Produced from Mixed Waste Materials with Pozzolanic Characteristics
Yen, Chi-Liang; Tseng, Dyi-Hwa; Wu, Yue-Ze
2012-01-01
Abstract Waste materials with pozzolanic characteristics, such as sewage sludge ash (SSA), coal combustion fly ash (FA), and granulated blast furnace slag (GBS), were reused as partial cement replacements for making cement mortar in this study. Experimental results revealed that with dual replacement of cement by SSA and GBS and triple replacement by SSA, FA, and GBS at 50% of total cement replacement, the compressive strength (Sc) of the blended cement mortars at 56 days was 93.7% and 92.9% of the control cement mortar, respectively. GBS had the highest strength activity index value and could produce large amounts of CaO to enhance the pozzolanic activity of SSA/FA and form calcium silicate hydrate gels to fill the capillary pores of the cement mortar. Consequently, the Sc development of cement mortar with GBS replacement was better than that without GBS, and the total pore volume of blended cement mortars with GBS/SSA replacement was less than that with FA/SSA replacement. In the cement mortar with modified SSA and GBS at 70% of total cement replacement, the Sc at 56 days was 92.4% of the control mortar. Modifying the content of calcium in SSA also increased its pozzolanic reaction. CaCl2 accelerated the pozzolanic activity of SSA better than lime did. Moreover, blending cement mortars with GBS/SSA replacement could generate more monosulfoaluminate to fill capillary pores. PMID:22783062
Idiopathic noncirrhotic portal hypertension: current perspectives
Riggio, Oliviero; Gioia, Stefania; Pentassuglio, Ilaria; Nicoletti, Valeria; Valente, Michele; d’Amati, Giulia
2016-01-01
The term idiopathic noncirrhotic portal hypertension (INCPH) has been recently proposed to replace terms, such as hepatoportal sclerosis, idiopathic portal hypertension, incomplete septal cirrhosis, and nodular regenerative hyperplasia, used to describe patients with a hepatic presinusoidal cause of portal hypertension of unknown etiology, characterized by features of portal hypertension (esophageal varices, nonmalignant ascites, porto-venous collaterals), splenomegaly, patent portal, and hepatic veins and no clinical and histological signs of cirrhosis. Physicians should learn to look for this condition in a number of clinical settings, including cryptogenic cirrhosis, a disease known to be associated with INCPH, drug administration, and even chronic alterations in liver function tests. Once INCPH is clinically suspected, liver histology becomes mandatory for the correct diagnosis. However, pathologists should be familiar with the histological features of INCPH, especially in cases in which histology is not only requested to exclude liver cirrhosis. PMID:27555800
Idiopathic noncirrhotic portal hypertension: current perspectives.
Riggio, Oliviero; Gioia, Stefania; Pentassuglio, Ilaria; Nicoletti, Valeria; Valente, Michele; d'Amati, Giulia
2016-01-01
The term idiopathic noncirrhotic portal hypertension (INCPH) has been recently proposed to replace terms, such as hepatoportal sclerosis, idiopathic portal hypertension, incomplete septal cirrhosis, and nodular regenerative hyperplasia, used to describe patients with a hepatic presinusoidal cause of portal hypertension of unknown etiology, characterized by features of portal hypertension (esophageal varices, nonmalignant ascites, porto-venous collaterals), splenomegaly, patent portal, and hepatic veins and no clinical and histological signs of cirrhosis. Physicians should learn to look for this condition in a number of clinical settings, including cryptogenic cirrhosis, a disease known to be associated with INCPH, drug administration, and even chronic alterations in liver function tests. Once INCPH is clinically suspected, liver histology becomes mandatory for the correct diagnosis. However, pathologists should be familiar with the histological features of INCPH, especially in cases in which histology is not only requested to exclude liver cirrhosis.
Contemporary Strategies for Rapid Recovery Total Hip Arthroplasty.
Stambough, Jeffrey B; Beaulé, Paul E; Nunley, Ryan M; Clohisy, John
2016-01-01
Over the past several years, rapid recovery protocols for total hip arthroplasty have evolved in parallel with advancements in pain management, regional anesthesia, focused rehabilitation, and the patient selection process. As fiscal pressures from payers of health care increase, surgical outcomes and complications are being scrutinized, which evokes a sense of urgency for arthroplasty surgeons as well as hospitals. The implementation of successful accelerated recovery pathways for total hip arthroplasty requires the coordinated efforts of surgeons, practice administrators, anesthesiologists, nurses, physical and occupational therapists, case managers, and postacute care providers. To optimize performance outcomes, it is important for surgeons to select patients who are eligible for rapid recovery. The fundamental tenets of multimodal pain control, regional anesthesia, prudent perioperative blood management, venous thromboembolic prophylaxis, and early ambulation and mobility should be collectively addressed for all patients who undergo primary total hip replacement.
Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina
2017-07-01
Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.
Bird, Steven T; Hartzema, Abraham G; Brophy, James M; Etminan, Mahyar; Delaney, Joseph A C
2013-02-05
There is an increased risk of venous thromboembolism among women taking oral contraceptives. However, whether there is an additional risk among women with polycystic ovary syndrome (PCOS) is unknown. We developed a population-based cohort from the IMS LifeLink Health Plan Claims Database, which includes managed care organizations in the United States. Women aged 18-46 years taking combined oral contraceptives and who had a claim for PCOS (n = 43 506) were matched, based on a propensity score, to control women (n = 43 506) taking oral contraceptives. Venous thromboembolism was defined using administrative coding and use of anticoagulation. We used Cox proportional hazards models to assess the relative risk (RR) of venous thromboembolism among users of combined oral contraceptives with and without PCOS. The incidence of venous thromboembolism among women with PCOS was 23.7/10 000 person-years, while that for matched controls was 10.9/10 000 person-years. Women with PCOS taking combined oral contraceptives had an RR for venous thromboembolism of 2.14 (95% confidence interval [CI] 1.41-3.24) compared with other contraceptive users. The incidence of venous thromboembolism was 6.3/10 000 person-years among women with PCOS not taking oral contraceptives; the incidence was 4.1/10 000 person-years among matched controls. The RR of venous thromboembolism among women with PCOS not taking oral contraceptives was 1.55 (95% CI 1.10-2.19). We found a 2-fold increased risk of venous thromboembolism among women with PCOS who were taking combined oral contraceptives and a 1.5-fold increased risk among women with PCOS not taking oral contraceptives. Physicians should consider the increased risk of venous thromboembolism when prescribing contraceptive therapy to women with PCOS.
Venous and Arterial Thromboses: Two Sides of the Same Coin?
Lippi, Giuseppe; Favaloro, Emmanuel J
2018-04-01
Arterial and venous thromboses are sustained by development of intraluminal thrombi, respectively, within the venous and arterial systems. The composition and structure of arterial and venous thrombi have been historically considered as being very different. Arterial thrombi (conventionally defined as "white") have been traditionally proposed to be composed mainly of fibrin and platelet aggregates, whilst venous thrombi (conventionally defined as "red") have been proposed as mostly being enriched in fibrin and erythrocytes. This archaic dichotomy seems ever more questionable, since it barely reflects the pathophysiology of thrombus formation in vivo. Both types of thrombi are actually composed of a complex fibrin network but, importantly, also contain essentially the same blood-borne cells (i.e., red blood cells, leukocytes, and platelets), and it is only the relative content of these individual elements that differ between venous and arterial clots or, otherwise, between thrombi generated under different conditions of blood flow and shear stress. Convincing evidence now suggests that either white or red intracoronary thrombi may be present in patients with myocardial infarction and, even more importantly, red thrombi may be more prone to distal embolization during percutaneous coronary intervention than those with lower content of erythrocytes. Conversely, it is now accepted that components traditionally considered to be involved "only" in arterial thrombosis are also represented in venous thrombosis. Thus, platelets comprise important components of venous clots, although they may be present in lower amounts here than in arterial thrombi, and von Willebrand factor is also represented in both arterial and venous thrombi. Of importance, such evidence thus supports the concept that adjunctive treatment normally associated to prevention of arterial thrombosis (e.g., aspirin) may have a role also in prevention and treatment of venous thrombosis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Ghaznavi, Habib; Soheili, Zahra; Samiei, Shahram; Soltanpour, Mohammad S
2015-12-01
There are limited data on the role of methylenetetrahydrofolate reductase C677T polymorphism and hyperhomocysteinemia as risk factors for cerebral venous thrombosis in Iranian population. We examined a possible association between fasting plasma homocysteine levels, methylenetetrahydrofolate reductase C677T polymorphism, and cerebral venous thrombosis in 50 patients with a diagnosis of cerebral venous thrombosis (20-63 years old) and 75 healthy controls (18-65 years old). Genotyping of the methylenetetrahydrofolate reductase C677T gene polymorphism was performed by PCR-restriction fragment length polymorphism analysis, and homocysteine levels were measured by enzyme immunoassay. Fasting plasma homocysteine levels were significantly higher in cerebral venous thrombosis patients than in controls (P = 0.015). Moreover, plasma homocysteine levels were significantly higher in methylenetetrahydrofolate reductase 677TT genotype compared to 677CT and 677CC genotypes in both cerebral venous thrombosis patients (P = 0.01) and controls (P = 0.03). Neither 677CT heterozygote genotype [odds ratio (OR) 1.35, 95% confidence interval (CI) 0.64-2.84, P = 0.556] nor 677TT homozygote genotype (OR 1.73, 95% CI 0.32-9.21, P = 0.833) was significantly associated with cerebral venous thrombosis. Additionally, no significant differences in the frequency of 677T allele between cerebral venous thrombosis patients and controls were identified (OR 1.31, 95% CI 0.69-2.50, P = 0.512). In conclusion, our study demonstrated that elevated plasma homocysteine levels are significant risk factors for cerebral venous thrombosis. Also, methylenetetrahydrofolate reductase 677TT genotype is not linked with cerebral venous thrombosis, but is a determinant of elevated plasma homocysteine levels.
Risk factors for venous port migration in a single institute in Taiwan
2014-01-01
Background An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications. Methods This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients. Results Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation. Conclusions Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor. PMID:24423026
Chemistry and Environments of Dolomitization —A Reappraisal
NASA Astrophysics Data System (ADS)
Machel, Hans-G.; Mountjoy, Eric W.
1986-05-01
Dolomitization of calcium carbonate can best be expressed by mass transfer reactions that allow for volume gain, preservation, or loss during the replacement process. Experimental data, as well as textures and porosities of natural dolomites, indicate that these reactions must include CO 32- and/or HCO 3- supplied by the solution to the reaction site. Since dolomite formation is thermodynamically favoured in solutions of (a) low Ca 2+/Mg 2+ ratios, (b) low Ca 2+/CO 32- (or Ca 2+/HCO 3-) ratios, and (c) high temperatures, the thermodynamic stability for the system calcite-dolomite-water is best represented in a diagram with these three parameters as axes. Kinetic considerations favour dolomitization under the same conditions, and additionally at low as well as at high salinities. If thermodynamic and kinetic considerations are combined, the following conditions and environments are considered chemically conducive to dolomitization: (1) environments of any salinity above thermodynamic and kinetic saturation with respect to dolomite (i.e. freshwater/seawater mixing zones, normal saline to hypersaline subtidal environments, hypersaline supratidal environments, schizohaline environments); (2) alkaline environments (i.e. those under the influence of bacterial reduction and/or fermentation processes, or with high input of alkaline continental groundwaters); and (3) many environments with temperatures greater than about 50°C (subsurface and hydrothermal environments). Whether or not massive, replacive dolostones are formed in these environments depends on a sufficient supply of magnesium, and thus on hydrologic parameters. Most massive dolostones, particularly those consisting of shallowing-upward cycles and capped by regional unconformities, have been interpreted to be formed according to either the freshwater/seawater mixing model or the sabkha with reflux model. However, close examination of natural mixing zones and exposed evaporitic environments reveals that the amounts of dolomite formed are small and texturally different from the massive, replacive dolostones commonly inferred to have been formed in these environments. Many shallowing-upward sequences are devoid of dolomite. It is therefore suggested that massive, replacive dolomitization during exposure is rare, if not impossible. Rather, only small quantities of dolomite (cement or replacement) are formed which may act as nuclei for later subsurface dolomitization. Alternatively, large-scale dolomitization may take place in shallow subtidal environments of moderate to strong hypersalinity. The integration of stratigraphic, petrographic, geochemical, and hydrological parameters suggests that the only environments capable of forming massive, replacive dolostones on a large scale are shallow, hypersaline subtidal environments and certain subsurface environments.
Safety and Efficacy Study of Sirolimus in Complicated Vascular Anomalies
2015-02-03
Kaposiform Hemangioendotheliomas; Tufted Angioma; Capillary Venous Lymphatic Malformation; Venous Lymphatic Malformation; Microcystic Lymphatic Malformation; Mucocutaneous Lymphangiomatosis and Thrombocytopenia; Capillary Lymphatic Arterial Venous Malformations; PTEN Overgrowth Syndrome With Vascular Anomaly; Lymphangiectasia Syndromes
Venous return curves obtained from graded series of valsalva maneuvers
NASA Technical Reports Server (NTRS)
Mastenbrook, S. M., Jr.
1974-01-01
The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.
Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi
2016-02-01
Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cannulation for veno-venous extracorporeal membrane oxygenation
2018-01-01
Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177
Manios, Yannis; Moschonis, George; Mavrogianni, Christina; Tsoutsoulopoulou, Konstantina; Kogkas, Stergios; Lambrinou, Christina-Paulina; Efstathopoulou, Eirini
2017-04-01
To compare the effects of three ready-to-eat mixed meals, with a high fiber content and low glycemic index, on postprandial glycemic and insulinemic response in patients with Type 2 diabetes mellitus (T2DM). The current study followed a prospective, three-way, cross-over design. Twenty-four patients with T2DM consumed three ready-to-eat mixed meals, i.e., "wild greens pie" (meal 1), "chicken burgers with boiled vegetables" (meal 2) and "vegetable moussaka" (meal 3) and an oral glucose load, all providing 50 g of carbohydrates. Venous blood was collected at 0, 30, 60, 90 and 120 min postprandial. Statistical analyses included repeated measures analysis of variance and calculations of the area under the glucose and insulin curves (AUC) for each one of the test meals and the oral glucose load. Patients consuming each one of the three mixed meals showed better postprandial glycemic responses compared to the oral glucose load (P < 0.001). Furthermore, patients consuming meal 3 showed a better insulinemic response compared to the oral glucose load and meal 1, after 60 and 120 min postprandial, respectively (P < 0.05). In addition, the increase observed in HOMA-IR values from T0 to T120 was significantly lower for meal 3, compared to the oral glucose load (P < 0.001). The three ready-to-eat mixed meals examined in the present study were found to elicit significantly lower glycemic responses compared to the oral glucose load in diabetic patients. The mixed meals examined in the present study could be proposed as effective, palatable and practical solutions for diabetics for glucose control.
A low cost igniter utilizing an SCB and titanium sub-hydride potassium perchlorate pyrotechnic
NASA Technical Reports Server (NTRS)
Bickes, R. W., Jr.; Grubelich, M. C.; Hartman, J. K.; McCampbell, C. B.; Churchill, J. K.
1994-01-01
A conventional NSI (NASA Standard Initiator) normally employs a hot-wire ignition element to ignite ZPP (zirconium potassium perchlorate). With minor modifications to the interior of a header similar to an NSI device to accommodate an SCB (semiconductor bridge), a low cost initiator was obtained. In addition, the ZPP was replaced with THKP (titanium sub-hydride potassium perchlorate) to obtain increased overall gas production and reduced static-charge sensitivity. This paper reports on the all-fire and no-fire levels obtained and on a dual mix device that uses THKP as the igniter mix and a thermite as the output mix.
Plasma Catecholamines and Stress Assessment in Men Exposed to Moderate Altitudes.
1982-01-01
posure, as evidenced by a significant fall in PC02 and a respiratory alkalosis , was able to improve blood oxygenation. Heart rate did not fall with...Survey . . . . 21 Oxygen Content and P02 ...... .. ..... 33 Venous PCO2 :’" 33 Venous pH . .. . . . . . . .. 37 Respiratory Rate ............. ... 37 Blood...a 68 L. Venous PC02 Levels . ... .............. 69 M. Venous pH. . .9. . . . . . .. . . . . . . . . . . . 70 N. Respiratory Rates
Rudofsky, G
1989-06-30
The drug combination of Ruscus-extract and hesperidine methyl chalcone (HMC) involves two basic mechanisms in the treatment of venous diseases: increase in venous tonicity and edema protection. This was shown in a double-blind study on 20 healthy volunteers by comparing the effectiveness of the individual substances, the combination and a placebo on the venous hemodynamics and the volume of the foot. Ruscus-extract augments the tonicity of the venous wall. This is expressed by a decrease in venous capacity (p less than 0.01), a reduction in the blood pool in the lower leg under orthostatic conditions, and a decrease in tissue volume of the foot and ankle (p less than 0.01). HMC lowers the capillary filtration rate (p less than 0.01) but augmented the blood pool. The increase in blood volume can be explained by dehydration of the tissue of the lower leg lowering the pressure of tissue on the venous system and increasing the blood pool in the limb. After administration of the combination, the blood volume was between the Ruscus and HMC volumes, while the effects on filtration rate, venous capacity and tissue volume corresponded to the changes seen after administration of HMC and Ruscus extract alone.
Sawano, Toyoaki; Nemoto, Tsuyoshi; Tsubokura, Masaharu; Leppold, Claire; Ozaki, Akihiko; Kato, Shigeaki; Kanazawa, Yukio
2016-08-24
Percutaneous endoscopic gastrostomy feeding is widely used as a route for enteral feeding for patients with impaired swallowing ability, particularly in older patients. Hepatic portal venous gas is a condition that may arise from several causes. Hepatic portal venous gas that develops after an endoscopic procedure is generally reported to be nonfatal, yet there is little information available concerning the characteristics of hepatic portal venous gas as a chronic complication of percutaneous endoscopic gastrostomy feeding. We experienced a case of hepatic portal venous gas that happened to be detected in an 81-year-old Japanese man with long-term percutaneous endoscopic gastrostomy use who was admitted to our hospital with aspiration pneumonia. While aspiration pneumonia was treated with antibiotics and suspension of tube feedings, he recovered from hepatic portal venous gas without any treatment. The presence of a percutaneous endoscopic gastrostomy tube may have induced hepatic portal venous gas through a mechanism in which vomiting led to increased abdominal pressure and eventually gastric emphysema. This case suggests that hepatic portal venous gas without any signs of bowel ischemia or emphysematous gastritis can resolve without treatment, which is a finding that could be helpful for clinicians who deal with those supported by percutaneous endoscopic gastrostomy feeding.
Taniguchi, Daisuke; Nakajima, Sho; Hayashida, Arisa; Kuroki, Takuma; Eguchi, Hiroto; Machida, Yutaka; Hattori, Nobutaka; Miwa, Hideto
2017-09-26
Acute necrotizing encephalopathy is one of the most devastating neurological complications of influenza virus infection. Acute necrotizing encephalopathy preferentially affects the thalamus bilaterally, as does deep cerebral venous thrombosis, which can lead to misdiagnosis. A 52-year-old Japanese woman infected with seasonal influenza B virus presented to the emergency care unit in our hospital with progressive alteration of her level of consciousness. Bilateral thalamic lesions were demonstrated by magnetic resonance imaging, leading to a tentative diagnosis of acute necrotizing encephalopathy. However, she had deep cerebral venous thrombosis, and the presence of diminished signal and enlargement of deep cerebral veins on T2*-weighted imaging contributed to a revised diagnosis of deep cerebral venous thrombosis. Anticoagulant therapy was initiated, leading to her gradual recovery, with recanalization of the deep venous system and straight sinus. To the best of our knowledge, these results represent the first report of deep cerebral venous thrombosis associated with influenza infection. It is clinically important to recognize that deep cerebral venous thrombosis, although rare, might be one of the neurological complications of influenza infection. In the presence of bilateral thalamic lesions in patients with influenza infection, deep cerebral venous thrombosis should be considered in addition to acute necrotizing encephalopathy. Delays in diagnosis and commencement of anticoagulant therapy can lead to unfavorable outcomes.
Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Naomi J.; Rosenfeld, Scott M.
This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usignmore » LED replacement lamps in art galleries housing national treasures.« less
Saha, Kaushik; Sengupta, Amitabha; Patra, Anupam; Jash, Debraj
2013-01-01
Bilateral venous thrombosis due to underlying malignancy is a rare entity. It is worthy to search for malignancy in patients of bilateral venous gangrene. Our patient presented with severe bilateral leg pain as a result of venous gangrene. There was associated left sided massive pleural effusion with scalp nodule. Fine needle aspiration cytology of scalp nodule revealed metastatic squamous cell carcinoma and fiber optic bronchoscopy guided biopsy from growth at left upper lobe bronchus confirmed the case as squamous cell carcinoma lung. It was rare for squamous cell carcinoma lung to present as bilateral venous gangrene with anticardiolipin antibody negative. PMID:24455526
NASA Astrophysics Data System (ADS)
Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin
2012-11-01
The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.
Green Infrastructure and Watershed-Scale Hydrology in Mixed Land Cover System
Urbanization results in replacement of pervious areas (e.g., vegetation, topsoil) with impervious surfaces such as roads, roofs, and parking lots, which cause reductions in interception, evapotranspiration, and infiltration, and increases in surface runoff (overland flow) and pol...
Evaluate the use of reclaimed concrete aggregate in french drain applications.
DOT National Transportation Integrated Search
2014-02-01
Recycled concrete aggregate (RCA) is often used as a replacement of virgin aggregate in road : foundations (base course), embankments, hot-mix asphalt, and Portland cement concrete; however, the : use of RCA in exfiltration drainage systems, such as ...
Evaluate the use of reclaimed concrete aggregate in french drain applications : [summary].
DOT National Transportation Integrated Search
2014-02-01
Recycled concrete aggregate (RCA) is often used : as a replacement of virgin aggregate in road : foundations (base course), embankments, hot-mix : asphalt, and Portland cement concrete. However, : the use of RCA in exfiltration drainage systems, : su...
Rotating Cylinder Treatment System Demonstration (Presentation)
In August 2008, a rotating cylinder treatment system (RCTSTM) demonstration was conducted near Gladstone, CO. The RCTSTM is a novel technology developed to replace the aeration/oxidation and mixing components of a conventional lime precipitation treatment s...
Rotating Cylinder Treatment System Demonstration
In August 2008, a rotating cylinder treatment system (RCTSTM) demonstration was conducted near Gladstone, CO. The RCTSTM is a novel technology developed to replace the aeration/oxidation and mixing components of a conventional lime precipitation treatment s...
Use of normal propyl bromide solvents for extraction and recovery of asphalt cements
DOT National Transportation Integrated Search
2000-11-01
Four normal propyl bromide (nPB) solvents were evaluated for use as chlorinated solvent replacements in typical hot mix asphalt (HMA) extraction and recovery processes. The experimental design included one method of extraction (centrifuge), one metho...
Browne, John; Jamieson, Liz; Lewsey, Jim; van der Meulen, Jan; Copley, Lynn; Black, Nick
2008-04-09
There has been considerable concern expressed about the outcomes achieved in Independent Sector Treatment Centres (ISTCs) introduced in England since 2003. Our aim was to compare the case-mix and patients' reported outcomes of surgery in ISTCs and in NHS providers. Prospective cohort study of 769 patients treated in six ISTCs and 1895 treated in 20 NHS providers (acute hospitals and treatment centres) in England during 2006-07. Participants underwent one of three day surgery procedures (inguinal hernia repair, varicose vein surgery, cataract extraction) or hip or knee replacement. Change in patient-reported health status and health related quality of life (measured using a disease-specific and a generic (EQ-5D) instrument) was assessed either 3-months (day surgery) or 6-months (hip/knee) after surgery. In addition patient-reported post-operative complications and an overall assessment of success of surgery were collected. Outcome measures were adjusted (using multivariable regression) for patient characteristics (disease severity, duration of symptoms, age, sex, socioeconomic status, general health, previous similar surgery, comorbidity). Post-operative response rates varied by procedure (73%-88%) and were similar for those treated in ISTCs and NHS facilities. Patients treated in ISTCs were healthier, were less likely to have any comorbidity and, for those undergoing cataract surgery or joint replacement, their primary condition was less severe. Those undergoing hernia repair or joint replacement were less likely to have had similar surgery before. When adjustment was made for pre-operative characteristics, patients undergoing cataract surgery or hip replacement in ISTCs achieved a slightly greater improvement in functional status and quality of life than those treated in NHS facilities, while the opposite was true of patients undergoing hernia repair. No significant differences were found for the two other procedures. Patients treated in ISTCs were less likely to report post-operative problems than those treated in NHS facilities for cataract surgery (Adjusted Odds Ratio 0.35; 95% CI 0.17-0.70), hernia repair (0.42; 0.28-0.63) and knee replacement (0.44; 0.28-0.69). Most patients described the result of their operation as excellent, very good or good, regardless of where they were treated. The case-mix of patients treated in ISTCs differs from that in NHS providers, in line with the intention of the contracts. Caution is needed in interpreting the observation that patients treated in ISTCs reported slightly better outcomes as very few ISTCs participated, case-mix adjustment might have been insufficient, and patients' reports might have been biased as they were more likely to be satisfied with the way they were treated.
A Clinical Tool for the Prediction of Venous Thromboembolism in Pediatric Trauma Patients.
Connelly, Christopher R; Laird, Amy; Barton, Jeffrey S; Fischer, Peter E; Krishnaswami, Sanjay; Schreiber, Martin A; Zonies, David H; Watters, Jennifer M
2016-01-01
Although rare, the incidence of venous thromboembolism (VTE) in pediatric trauma patients is increasing, and the consequences of VTE in children are significant. Studies have demonstrated increasing VTE risk in older pediatric trauma patients and improved VTE rates with institutional interventions. While national evidence-based guidelines for VTE screening and prevention are in place for adults, none exist for pediatric patients, to our knowledge. To develop a risk prediction calculator for VTE in children admitted to the hospital after traumatic injury to assist efforts in developing screening and prophylaxis guidelines for this population. Retrospective review of 536,423 pediatric patients 0 to 17 years old using the National Trauma Data Bank from January 1, 2007, to December 31, 2012. Five mixed-effects logistic regression models of varying complexity were fit on a training data set. Model validity was determined by comparison of the area under the receiver operating characteristic curve (AUROC) for the training and validation data sets from the original model fit. A clinical tool to predict the risk of VTE based on individual patient clinical characteristics was developed from the optimal model. Diagnosis of VTE during hospital admission. Venous thromboembolism was diagnosed in 1141 of 536,423 children (overall rate, 0.2%). The AUROCs in the training data set were high (range, 0.873-0.946) for each model, with minimal AUROC attenuation in the validation data set. A prediction tool was developed from a model that achieved a balance of high performance (AUROCs, 0.945 and 0.932 in the training and validation data sets, respectively; P = .048) and parsimony. Points are assigned to each variable considered (Glasgow Coma Scale score, age, sex, intensive care unit admission, intubation, transfusion of blood products, central venous catheter placement, presence of pelvic or lower extremity fractures, and major surgery), and the points total is converted to a VTE risk score. The predicted risk of VTE ranged from 0.0% to 14.4%. We developed a simple clinical tool to predict the risk of developing VTE in pediatric trauma patients. It is based on a model created using a large national database and was internally validated. The clinical tool requires external validation but provides an initial step toward the development of the specific VTE protocols for pediatric trauma patients.
2014-08-10
sulfur , nitrate salts, carbon (charcoal) – Unreliable ballistic properties – Could not be used in large diameter, high thrust motors • Consolidation of...a programmed manner – Molten Asphalt • Heated to a fluid melt, mixed with oxidant, cast into motor cavity and allowed to cool • Low solids content...which could be formulated • Poor mechanical properties of highly loaded asphalt – Acrylate monomers • Monomers mixed with oxidizers and curative (divinyl
1983-01-01
7- peripheral intravenous route. CARE OF THE CENTRAL VENOUS CATHETER Central venous catheter insertion requires the follow- ing skin preparation: 1...receiving parenteral nutrition who develop sepsis from central venous catheters may show persistent temperature spikes to 38.9 *C to 40.0 *C every 12-24...hours. Evaluating the central venous catheter as the etiology for febrile episodes is often difficult because many patients have other potential
Hydrothorax after Central Venous Catheterization
Rudge, C. J.; Bewick, M.; McColl, I.
1973-01-01
Three patients are described who developed hydrothorax as a complication of central venous catheterization. Respiratory distress associated with physical signs of fluid in the chest should arouse suspicion that the venous catheter has perforated the wall of the vein. The complications of central venous catheterization are reviewed and three cases of hydrothorax are presented. Comments on the prevention of these complications, their diagnosis and treatment if they occur, are made. ImagesFIG. 1FIG. 2 PMID:4717421
2004-06-01
Abstract. The venous blood flow during stretching and deep breathing in the sitting posture was examined in the present study. First, an...increase in the venous return. Therefore, we suggest that stretching and deep breathing can be used sometimes as preventive measures for deep vein...thrombosis during prolonged sitting. Keywords. Venous blood flow, Near infrared spectroscopy, Deep vein thrombosis. 1. Introduction It has been
Extrinsic cerebral venous sinus obstruction resulting in intracranial hypertension
Goldsmith, P; Burn, D; Coulthard, A; Jenkins, A
1999-01-01
We report the case of a 70-year-old man reporting with headache and visual disturbances who was being treated for prostate cancer. Investigations showed him to have intracranial hypertension caused by venous sinus obstruction. Patients with metastatic disease and raised intracranial pressure in the absence of focal signs should be considered as possible cases of venous outflow obstruction. Keywords: intracranial hypertension; venous sinus thrombosis; malignancy PMID:10616691
Acute venous sinus thrombosis after chickenpox infection.
Sardana, Vijay; Mittal, Lal Chand; Meena, S R; Sharma, Deepti; Khandelwal, Girish
2014-08-01
Chickenpox is one of the classic childhood diseases. Recently chicken pox has been reported in adults with more severe systemic and neurological complications. Cerebral venous thrombosis (CVT) is a life threatening disorder if not treated in time. We report a patient with post varicella CVT as a rare complication of primary Varicella zoster virus. Vasculitic arterial infarction is known while venous stroke has rarely been reported with Varicella-zoster virus infection. Here, we report an immunocompetent 30 yr old male who developed chickenpox after contact with his daughter two month back. He presented with acute neurological deficit, one week after onset of skin lesion. MR venography revealed non-visualisation of left transverse sinus and left sigmoid sinus suggestive of venous sinus thrombosis. Varicella infection is rarely associated with venous sinus thrombosis. Possibly hypercoagulable state produced by the infection or direct invasion of virus in venous endothelial wall with subsequent damage to endothelium leading to thrombosis could be the cause.
Occult pulmonary embolism: a common occurrence in deep venous thrombosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorfman, G.S.; Cronan, J.J.; Tupper, T.B.
1987-02-01
Ventilation-perfusion scans were used in a prospective study to determine the prevalence of occult pulmonary embolus in proven deep venous thrombosis. Fifty-eight patients without symptoms of pulmonary embolism, but with venographically proven deep venous thrombosis, were subjected to chest radiographs, /sup 99m/Tc macroaggregated-albumin perfusion scans, and /sup 133/Xe ventilation scans. Of the 49 patients with deep venous thrombosis proximal to the calf veins, 17 (35%) had high-probability scans. Of all 58 patients, only 12 (21%) had normal scans. When the study population was compared with a group of 430 patients described in reports of pulmonary perfusion in asymptomatic persons, amore » significantly higher percentage of high-probability scans was found in the study population with deep venous thrombosis. Baseline ventilation-perfusion lung scanning is valuable for patients with proven above-knee deep venous thrombosis.« less
Stasis Dermatitis: Pathophysiology, Evaluation, and Management.
Sundaresan, Swaminathan; Migden, Michael R; Silapunt, Sirunya
2017-06-01
Stasis dermatitis commonly occurs in older age. It is caused by venous hypertension resulting from retrograde flow due to incompetent venous valves, valve destruction, or obstruction of the venous system. Further tissue changes arise from an inflammatory process mediated by metalloproteinases, which are up-regulated by ferric ion from extravasated red blood cells. Stasis dermatitis presents initially as poorly demarcated erythematous plaques of the lower legs bilaterally, classically involving the medial malleolus. It is one of the spectrum of cutaneous findings that may result from chronic venous insufficiency. Its mimics include cellulitis, contact dermatitis, and pigmented purpuric dermatoses. Duplex ultrasound is useful in demonstrating venous reflux when the clinical diagnosis of stasis dermatitis is inadequate. Conservative treatment involves the use of compression therapy directed at improving ambulatory venous pressure. Interventional therapy currently includes minimally invasive techniques such as endovenous thermal ablation and ultrasound-guided foam sclerotherapy, which have supplanted the use of open surgical techniques.
Unilateral Loss of Spontaneous Venous Pulsations in an Astronaut
NASA Technical Reports Server (NTRS)
Mader, Thomas H.; Gibson, C. Robert; Lee, Andrew G.; Patel, Nimesh; Hart, Steven; Pettit, Donald R.
2014-01-01
Spontaneous venous pulsations seen on the optic nerve head (optic disc) are presumed to be caused by fluctuations in the pressure gradient between the intraocular and retrolaminar venous systems. The disappearance of previously documented spontaneous venous pulsations is a well-recognized clinical sign usually associated with a rise in intracranial pressure and a concomitant bilateral elevation of pressure in the subarachnoid space surrounding the optic nerves. In this correspondence we report the unilateral loss of spontaneous venous pulsations in an astronaut 5 months into a long duration space flight. We documented a normal lumbar puncture opening pressure 8 days post mission. The spontaneous venous pulsations were also documented to be absent 21 months following return to Earth.. We hypothesize that these changes may have resulted from a chronic unilateral rise in optic nerve sheath pressure caused by a microgravity-induced optic nerve sheath compartment syndrome.
Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock
NASA Astrophysics Data System (ADS)
Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.
2013-03-01
Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.
Venous thromboembolism associated with air travel: a report of 33 patients.
Mercer, A; Brown, J D
1998-02-01
The medical literature suggests long distance travel, particularly air travel, may be a risk factor for venous thromboembolism, but the risk is poorly quantified. We reviewed 134 records of patients hospitalized with venous thromboembolism for comments regarding recent travel. Patients who had traveled within 31 d prior to venous thromboembolism were defined as recent travelers. Of 134 patients records, 66 (49%) had documented inquiries regarding travel and 33 (50%) were recent air travelers. Data regarding demographics, mode of travel, day of onset of symptoms in relation to travel, and other risk factors for venous thromboembolism were abstracted from the records of the recent travelers. There were 12 (36%) travelers who had no other predisposition for venous thromboembolism. All had traveled non-stop by aircraft for 4 or more hours; none was identified as a crew-member. The median day of onset of venous thromboembolism was on travel day 4 (range: day 1-31). There were 8 (24%) patients who had onset during air travel or on the day of arrival, and 27 (82%) had onset by travel day 15. Air travel for 4 or more hours within the preceding 31 d was the most common risk factor for venous thromboembolism in our study patients and was present in 50%. This incidence is much higher than previously described, perhaps due to limiting the study population to those in which the presence or absence of travel was documented. Prospective studies are needed to better define the risk factors for venous thromboembolism among long distance air passengers and crew-members, and to determine effective preventive measures.
Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna
2014-01-01
Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.
Risk factors for venous thrombosis associated with peripherally inserted central venous catheters
Pan, Longfang; Zhao, Qianru; Yang, Xiangmei
2014-01-01
To evaluate the risk factors associated with an increased risk of symptomatic peripherally inserted central venous catheter (PICC)-related venous thrombosis. Retrospective analyses identified 2313 patients who received PICCs from 1 January 2012 to 31 December 2013. All 11 patients with symptomatic PICC-related venous thrombosis (thrombosis group) and 148 who did not have thromboses (non-thrombosis group) were selected randomly. The medical information of 159 patients (age, body mass index (BMI), diagnosis, smoking history, nutritional risk score, platelet count, leucocyte count as well as levels of D-dimer, fibrinogen, and degradation products of fibrin) were collected. Logistic regression analysis was undertaken to determine the risk factors for thrombosis. Of 2313 patients, 11 (0.47%) were found to have symptomatic PICC-related venous thrombosis by color Doppler ultrasound. Being bedridden for a long time (odds ratio [(OR]), 17.774; P=0.0017), D-dimer >5 mg/L (36.651; 0.0025) and suffering from one comorbidity (8.39; 0.0265) or more comorbidities (13.705; 0.0083) were the major risk factors for PICC-catheter related venous thrombosis by stepwise logistic regression analysis. Among 159 patients, the prevalence of PICC-associated venous thrombosis in those with ≥1 risk factor was 10.34% (12/116), in those with ≥2 risk factors was 20.41% (10/49), and in those with >3 risk factors was 26.67% (4/15). Being bedridden >72 h, having increased levels of D-dimer (>5 mg/L) and suffering from comorbidities were independent risk factors of PICC-related venous thrombosis. PMID:25664112
NASA Astrophysics Data System (ADS)
Zhang, Xiancheng; Noda, Shigeho; Himeno, Ryutaro; Liu, Hao
2017-06-01
We present a novel methodology and strategy to predict pressures and flow rates in the global cardiovascular network in different postures varying from supine to upright. A closed-loop, multiscale mathematical model of the entire cardiovascular system (CVS) is developed through an integration of one-dimensional (1D) modeling of the large systemic arteries and veins, and zero-dimensional (0D) lumped-parameter modeling of the heart, the cardiac-pulmonary circulation, the cardiac and venous valves, as well as the microcirculation. A versatile junction model is proposed and incorporated into the 1D model to cope with splitting and/or merging flows across a multibranched junction, which is validated to be capable of estimating both subcritical and supercritical flows while ensuring the mass conservation and total pressure continuity. To model gravitational effects on global hemodynamics during postural change, a robust venous valve model is further established for the 1D venous flows and distributed throughout the entire venous network with consideration of its anatomically realistic numbers and locations. The present integrated model is proven to enable reasonable prediction of pressure and flow rate waveforms associated with cardiopulmonary circulation, systemic circulation in arteries and veins, as well as microcirculation within normal physiological ranges, particularly in mean venous pressures, which well match the in vivo measurements. Applications of the cardiovascular model at different postures demonstrate that gravity exerts remarkable influence on arterial and venous pressures, venous returns and cardiac outputs whereas venous pressures below the heart level show a specific correlation between central venous and hydrostatic pressures in right atrium and veins.
Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas
2010-01-01
This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.
Computational modeling of venous sinus stenosis in idiopathic intracranial hypertension
Levitt, Michael R; McGah, Patrick M; Moon, Karam; Albuquerque, Felipe C; McDougall, Cameron G; Kalani, M Yashar S; Kim, Louis J; Aliseda, Alberto
2016-01-01
Background and Purpose Idiopathic intracranial hypertension has been associated with dural venous sinus stenosis in some patients, but the hemodynamic environment of the dural venous sinuses has not been quantitatively described. Here, we present the first such computational fluid dynamics model using patient-specific blood pressure measurements. Materials and Methods Six patients with idiopathic intracranial hypertension and at least one stenosis or atresia at the transverse-sigmoid sinus junction underwent MRV followed by cerebral venography and manometry throughout the dural venous sinuses. Patient-specific computational fluid dynamics models were created using MRV anatomy, with venous pressure measurements as boundary conditions. Blood flow and wall shear stress were calculated for each patient. Results Computational models of dural venous sinuses were successfully reconstructed in all six patients with patient-specific boundary conditions. Three patients demonstrated a pathologic pressure gradient (≥ 8 mm Hg) across four dural venous sinus stenoses. Small sample size precludes statistical comparisons, but average overall flow throughout the dural venous sinuses of patients with pathologic pressure gradients was higher than in those without (1041.00 ± 506.52 vs. 358.00 ± 190.95 mL/min). Wall shear stress was also higher across stenoses in patients with pathologic pressure gradients (37.66 ± 48.39 vs 7.02 ± 13.60 Pa). Conclusion The hemodynamic environment of the dural venous sinuses can be computationally modeled using patient-specific anatomy and physiological measurements in patients with idiopathic intracranial hypertension. There was substantially higher blood flow and wall shear stress in patients with pathological pressure gradients. PMID:27197986
Effects of abdominal pressure on venous return: abdominal vascular zone conditions.
Takata, M; Wise, R A; Robotham, J L
1990-12-01
The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.
Distinguishing the opponents promotes cooperation in well-mixed populations
NASA Astrophysics Data System (ADS)
Wardil, Lucas; da Silva, Jafferson K. L.
2010-03-01
Cooperation has been widely studied when an individual strategy is adopted against all coplayers. In this context, some extra mechanisms, such as punishment, reward, memory, and network reciprocity must be introduced in order to keep cooperators alive. Here, we adopt a different point of view. We study the adoption of different strategies against different opponents instead of adoption of the same strategy against all of them. In the context of the prisoner dilemma, we consider an evolutionary process in which strategies that provide more benefits are imitated and the players replace the strategy used in one of the interactions furnishing the worst payoff. Individuals are set in a well-mixed population, so that network reciprocity effect is excluded and both synchronous and asynchronous updates are analyzed. As a consequence of the replacement rule, we show that mutual cooperation is never destroyed and the initial fraction of mutual cooperation is a lower bound for the level of cooperation. We show by simulation and mean-field analysis that (i) cooperation dominates for synchronous update and (ii) only the initial mutual cooperation is maintained for asynchronous update. As a side effect of the replacement rule, an “implicit punishment” mechanism comes up in a way that exploitations are always neutralized providing evolutionary stability for cooperation.