NASA Technical Reports Server (NTRS)
Murray, John J.; Schaffner, Philip R.; Minnis, Patrick; Nguyen, Louis; Delnore, Victor E.; Daniels, Taumi S.; Grainger, C. A.; Delene, D.; Wolff, C. A.
2004-01-01
The Tropospheric Airborne Meteorological Data Reporting (TAMDAR) sensor was deployed onboard the University of North Dakota Citation II aircraft in the Alliance Icing Research Study (AIRS II) from Nov 19 through December 14, 2003. TAMDAR is designed to measure and report winds, temperature, humidity, turbulence and icing from regional commercial aircraft (Daniels et. al., 2004). TAMDAR icing sensor performance is compared to a) in situ validation data from the Citation II sensor suite, b) Current Icing Potential products developed by the National Center for Atmospheric Research (NCAR) and available operationally on the NOAA Aviation Weather Center s Aviation Digital Data Server (ADDS) and c) NASA Advanced Satellite Aviation-weather Products (ASAP) cloud microphysical products.
TAMDAR Sensor Validation in 2003 AIRS II
NASA Technical Reports Server (NTRS)
Daniels, Taumi S.; Murray, John J.; Anderson, Mark V.; Mulally, Daniel J.; Jensen, Kristopher R.; Grainger, Cedric A.; Delene, David J.
2005-01-01
This study entails an assessment of TAMDAR in situ temperature, relative humidity and winds sensor data from seven flights of the UND Citation II. These data are undergoing rigorous assessment to determine their viability to significantly augment domestic Meteorological Data Communications Reporting System (MDCRS) and the international Aircraft Meteorological Data Reporting (AMDAR) system observational databases to improve the performance of regional and global numerical weather prediction models. NASA Langley Research Center participated in the Second Alliance Icing Research Study from November 17 to December 17, 2003. TAMDAR data taken during this period is compared with validation data from the UND Citation. The data indicate acceptable performance of the TAMDAR sensor when compared to measurements from the UND Citation research instruments.
2014-08-01
Using real-time weather data from an unmanned aircraft system to support the advanced research version of the weather research and forecast model... system that is used to transmit some MDCRS observations, the Aircraft Communications Addressing and Reporting System (ACARS). A new network of aircraft ...Technical Analysis and Applications Center, and AirDat LLC developed a modified TAMDAR sensor referred to as TAMDAR- Unmanned Aerial System (TAMDAR-U) for
NASA Technical Reports Server (NTRS)
Tsoucalas, George; Daniels, Taumi S.; Zysko, Jan; Anderson, Mark V.; Mulally, Daniel J.
2010-01-01
As part of the National Aeronautics and Space Administration's Aviation Safety and Security Program, the Tropospheric Airborne Meteorological Data Reporting project (TAMDAR) developed a low-cost sensor for aircraft flying in the lower troposphere. This activity was a joint effort with support from Federal Aviation Administration, National Oceanic and Atmospheric Administration, and industry. This paper reports the TAMDAR sensor performance validation and verification, as flown on board NOAA Lockheed WP-3D aircraft. These flight tests were conducted to assess the performance of the TAMDAR sensor for measurements of temperature, relative humidity, and wind parameters. The ultimate goal was to develop a small low-cost sensor, collect useful meteorological data, downlink the data in near real time, and use the data to improve weather forecasts. The envisioned system will initially be used on regional and package carrier aircraft. The ultimate users of the data are National Centers for Environmental Prediction forecast modelers. Other users include air traffic controllers, flight service stations, and airline weather centers. NASA worked with an industry partner to develop the sensor. Prototype sensors were subjected to numerous tests in ground and flight facilities. As a result of these earlier tests, many design improvements were made to the sensor. The results of tests on a final version of the sensor are the subject of this report. The sensor is capable of measuring temperature, relative humidity, pressure, and icing. It can compute pressure altitude, indicated air speed, true air speed, ice presence, wind speed and direction, and eddy dissipation rate. Summary results from the flight test are presented along with corroborative data from aircraft instruments.
Tropospheric Airborne Meteorological Data Reporting (TAMDAR) Sensor Development
NASA Technical Reports Server (NTRS)
Daniels, Taumi S.
2002-01-01
In response to recommendations from the National Aviation Weather Program Council, the National Aeronautics and Space Administration (NASA) is working with industry to develop an electronic pilot reporting capability for small aircraft. This paper describes the Tropospheric Airborne Meteorological Data Reporting (TAMDAR) sensor development effort. NASA is working with industry to develop a sensor capable of measuring temperature, relative humidity, magnetic heading, pressure, icing, and average turbulence energy dissipation. Users of the data include National Centers for Environmental Prediction (NCEP) forecast modelers, air traffic controllers, flight service stations, airline operation centers, and pilots. Preliminary results from flight tests are presented.
Tropospheric Airborne Meteorological Data Reporting (TAMDAR) Overview
NASA Technical Reports Server (NTRS)
Daniels, Taumi S.; Moninger, William R.; Mamrosh, Richard D.
2008-01-01
This paper is an overview of the Tropospheric Airborne Meteorological Data Reporting (TAMDAR) project, giving some history on the project, various applications of the atmospheric data, and future ideas and plans. As part of NASA's Aviation Safety and Security Program, the TAMDAR project developed a small low-cost sensor that collects useful meteorological data and makes them available in near real time to improve weather forecasts. This activity has been a joint effort with FAA, NOAA, universities, and industry. A tri-agency team collaborated by developing a concept of operations, determining the sensor specifications, and evaluating sensor performance as reported by Moosakhanian et. al. (2006). Under contract with Georgia Tech Research Institute, NASA worked with AirDat of Raleigh, NC to develop the sensor. The sensor is capable of measuring temperature, relative humidity, pressure, and icing. It can compute pressure altitude, indicated and true air speed, ice accretion rate, wind speed and direction, peak and average turbulence, and eddy dissipation rate. The overall development process, sensor capabilities, and performance based on ground and flight tests is reported by Daniels (2002), Daniels et. al. (2004) and by Tsoucalas et. al. (2006). An in-service evaluation of the sensor was performed called the Great Lakes Fleet Experiment (GLFE), first reported by Moninger et. al. (2004) and Mamrosh et. al. (2005). In this experiment, a Mesaba Airlines fleet was equipped to collect meteorological data over the Great Lakes region during normal revenue-producing flights.
NASA Technical Reports Server (NTRS)
Murray, John J.; Nguyen, Louis A.; Daniels, Taumi; Minnis, Patrick; Schaffner, Phillip R.; Cagle, Melinda F.; Nordeen, Michele L.; Wolff, Cory A.; Anderson, Mark V.; Mulally, Daniel J.
2005-01-01
NASA Langley Research Center and its research partners from the University of North Dakota (UND) and the National Center for Atmospheric Research (NCAR) participated in the AIRS II campaign from November 17 to December 17, 2003. AIRS II provided the opportunity to compare TAMDAR in situ in-flight icing condition assessments with in situ data from the UND Citation II aircraft's Rosemont system. TAMDAR is designed to provide a general warning of ice accretion and to report it directly into the Meteorological Data Communications and Reporting System (MDCRS). In addition to evaluating TAMDAR with microphysical data obtained by the Citation II, this study also compares these data to the NWS operational in-flight icing Current Icing Potential (CIP) graphic product and with the NASA Advanced Satellite Aviation-weather Products (ASAP) Icing Severity product. The CIP and ASAP graphics are also examined in this study to provide a context for the Citation II's sorties in AIRS II.
Tropospheric Airborne Meteorological Data Reporting (TAMDAR) Sensor Development
NASA Technical Reports Server (NTRS)
Daniels, Taumi S.; Tsoucalas, George; Anderson, Mark; Mulally, Daniel; Moninger, William; Mamrosh, Richard
2004-01-01
One of the recommendations of the National Aviation Weather Program Council was to expand and institutionalize the generation, dissemination, and use of automated pilot reports (PIREPS) to the full spectrum of the aviation community, including general aviation. In response to this and other similar recommendations, NASA initiated cooperative research into the development of an electronic pilot reporting capability (Daniels 2002). The ultimate goal is to develop a small low-cost sensor, collect useful meteorological observations below 25,000 ft., downlink the data in near real time, and use the data to improve weather forecasts. Primary users of the data include pilots, who are one targeted audience for the improved weather information that will result from the TAMDAR data. The weather data will be disseminated and used to improve aviation safety by providing pilots with enhanced weather situational awareness. In addition, the data will be used to improve the accuracy and timeliness of weather forecasts. Other users include air traffic controllers, flight service stations, and airline weather centers. Additionally, the meteorological data collected by TAMDAR is expected to have a significant positive impact on forecast accuracy for ground based applications.
Understanding the k-5/3 to k-2.4 spectral break in aircraft wind data
NASA Astrophysics Data System (ADS)
Pinel, J.; Lovejoy, S.; Schertzer, D. J.; Tuck, A.
2010-12-01
A fundamental issue in atmospheric dynamics is to understand how the statistics of fluctuations of various fields vary with their space-time scale. The classical - and still “standard” model - dates back to Kraichnan and Charney’s work on 2-D and geostrophic (quasi 2-D) turbulence at the end of the 1960’s and early 1970’s. It postulates an isotropic 2-D turbulent regime at large scales and an isotropic 3D regime at small scales separated by a “dimensional transition” (once called a “mesoscale gap”) near the pressure scale height of ≈10 km. By the early 1980’s a quite different model emerged, the 23/9-D scaling model in which the dynamics were postulated to be dominated (over wide scale ranges) by a strongly anisotropic scale invariant cascade mechanism with structures becoming flatter and flatter at larger and larger scales in a scaling manner: the isotropy assumptions were discarded but the scaling and cascade assumptions retained. Today, thanks to the revolution in geodata and atmospheric models - both in quality and quantity - the 23/9-D model can explain the observed horizontal cascade structures in remotely sensed radiances, in meteorological “reanalyses”, in meteorological models, in high resolution drop sonde vertical analyses, of lidar vertical sections etc. All of these analyses directly contradict the standard model which predicts drastic “dimensional transitions” for scalar quantities. Indeed, until recently the only unexplained feature was a scale break in aircraft spectra of the (vector) horizontal wind somewhere between about 40 and 200 km. However - contrary to repeated claims - and thanks to a reanalysis of the historical papers - the transition that had been observed since the 1980’s was not between k^-5/3 and k^-3 but rather between k^-5/3 and k^-2.4. By 2009, the standard model was thus hanging by a thread. This was cut when careful analysis of scientific aircraft data allowed the 23/9-D model to explain the large scale k-2.4 regime as an artefact of the aircraft following a sloping trajectory: at large enough scales, the spectrum is simply dominated by vertical rather than horizontal fluctuations which have the required k^-2.4 form. Since aircraft frequently follow gently sloping isobars, this neatly explains the last obstacle to wide range anisotropic scaling models finally opening the door to an urgently needed consensus on the statistical structure of the atmosphere. However, objections remain: at large enough scales do isobaric and isoheight spectra really have different exponents? In this presentation we attempted to study this issue in more detail than before by analyzed data measured by commercial aircrafts through the Tropospheric Airborne Meteorological Data Reporting (TAMDAR) system over CONUS during year 2009. The TAMDAR system allows us to calculate the statistical properties of the wind field on constant pressure and altitude levels. Various statistical exponents were calculated (velocity increment in terms of horizontal, vertical displacement, pressure and time) and we show here what we learned and how this analysis can help with solving this question.
2012-03-01
for enabling condition based maintenance plus in Army ground vehicles. The sensor study was driven from Failure Mode Effects Analysis ( FMEA ...of Tables Table 1. Sensor technology baseline study based on engine FMEA report. ...................................5 Table 2. Sensor technology...baseline study based on transmission FMEA report. .........................8 Table 3. Sensor technology baseline study based on alternator FMEA report
Waddell, Kimberly J; Lang, Catherine E
2018-03-10
To compare self-reported with sensor-measured upper limb (UL) performance in daily life for individuals with chronic (≥6mo) UL paresis poststroke. Secondary analysis of participants enrolled in a phase II randomized, parallel, dose-response UL movement trial. This analysis compared the accuracy and consistency between self-reported UL performance and sensor-measured UL performance at baseline and immediately post an 8-week intensive UL task-specific intervention. Outpatient rehabilitation. Community-dwelling individuals with chronic (≥6mo) UL paresis poststroke (N=64). Not applicable. Motor Activity Log amount of use scale and the sensor-derived use ratio from wrist-worn accelerometers. There was a high degree of variability between self-reported UL performance and the sensor-derived use ratio. Using sensor-based values as a reference, 3 distinct categories were identified: accurate reporters (reporting difference ±0.1), overreporters (difference >0.1), and underreporters (difference <-0.1). Five of 64 participants accurately self-reported UL performance at baseline and postintervention. Over half of participants (52%) switched categories from pre-to postintervention (eg, moved from underreporting preintervention to overreporting postintervention). For the consistent reporters, no participant characteristics were found to influence whether someone over- or underreported performance compared with sensor-based assessment. Participants did not consistently or accurately self-report UL performance when compared with the sensor-derived use ratio. Although self-report and sensor-based assessments are moderately associated and appear similar conceptually, these results suggest self-reported UL performance is often not consistent with sensor-measured performance and the measures cannot be used interchangeably. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Battery-free Wireless Sensor Network For Advanced Fossil-Fuel Based Power Generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yi Jia
2011-02-28
This report summarizes technical progress achieved during the project supported by the Department of Energy under Award Number DE-FG26-07NT4306. The aim of the project was to conduct basic research into battery-free wireless sensing mechanism in order to develop novel wireless sensors and sensor network for physical and chemical parameter monitoring in a harsh environment. Passive wireless sensing platform and five wireless sensors including temperature sensor, pressure sensor, humidity sensor, crack sensor and networked sensors developed and demonstrated in our laboratory setup have achieved the objective for the monitoring of various physical and chemical parameters in a harsh environment through remotemore » power and wireless sensor communication, which is critical to intelligent control of advanced power generation system. This report is organized by the sensors developed as detailed in each progress report.« less
Estimates of Social Contact in a Middle School Based on Self-Report and Wireless Sensor Data.
Leecaster, Molly; Toth, Damon J A; Pettey, Warren B P; Rainey, Jeanette J; Gao, Hongjiang; Uzicanin, Amra; Samore, Matthew
2016-01-01
Estimates of contact among children, used for infectious disease transmission models and understanding social patterns, historically rely on self-report logs. Recently, wireless sensor technology has enabled objective measurement of proximal contact and comparison of data from the two methods. These are mostly small-scale studies, and knowledge gaps remain in understanding contact and mixing patterns and also in the advantages and disadvantages of data collection methods. We collected contact data from a middle school, with 7th and 8th grades, for one day using self-report contact logs and wireless sensors. The data were linked for students with unique initials, gender, and grade within the school. This paper presents the results of a comparison of two approaches to characterize school contact networks, wireless proximity sensors and self-report logs. Accounting for incomplete capture and lack of participation, we estimate that "sensor-detectable", proximal contacts longer than 20 seconds during lunch and class-time occurred at 2 fold higher frequency than "self-reportable" talk/touch contacts. Overall, 55% of estimated talk-touch contacts were also sensor-detectable whereas only 15% of estimated sensor-detectable contacts were also talk-touch. Contacts detected by sensors and also in self-report logs had longer mean duration than contacts detected only by sensors (6.3 vs 2.4 minutes). During both lunch and class-time, sensor-detectable contacts demonstrated substantially less gender and grade assortativity than talk-touch contacts. Hallway contacts, which were ascertainable only by proximity sensors, were characterized by extremely high degree and short duration. We conclude that the use of wireless sensors and self-report logs provide complementary insight on in-school mixing patterns and contact frequency.
Pellerin, Brian A.; Bergamaschi, Brian A.; Downing, Bryan D.; Saraceno, John Franco; Garrett, Jessica D.; Olsen, Lisa D.
2013-01-01
The recent commercial availability of in situ optical sensors, together with new techniques for data collection and analysis, provides the opportunity to monitor a wide range of water-quality constituents on time scales in which environmental conditions actually change. Of particular interest is the application of ultraviolet (UV) photometers for in situ determination of nitrate concentrations in rivers and streams. The variety of UV nitrate sensors currently available differ in several important ways related to instrument design that affect the accuracy of their nitrate concentration measurements in different types of natural waters. This report provides information about selection and use of UV nitrate sensors by the U.S. Geological Survey to facilitate the collection of high-quality data across studies, sites, and instrument types. For those in need of technical background and information about sensor selection, this report addresses the operating principles, key features and sensor design, sensor characterization techniques and typical interferences, and approaches for sensor deployment. For those needing information about maintaining sensor performance in the field, key sections in this report address maintenance and calibration protocols, quality-assurance techniques, and data formats and reporting. Although the focus of this report is UV nitrate sensors, many of the principles can be applied to other in situ optical sensors for water-quality studies.
Estimates of Social Contact in a Middle School Based on Self-Report and Wireless Sensor Data
Leecaster, Molly; Toth, Damon J. A.; Pettey, Warren B. P.; Rainey, Jeanette J.; Gao, Hongjiang; Uzicanin, Amra; Samore, Matthew
2016-01-01
Estimates of contact among children, used for infectious disease transmission models and understanding social patterns, historically rely on self-report logs. Recently, wireless sensor technology has enabled objective measurement of proximal contact and comparison of data from the two methods. These are mostly small-scale studies, and knowledge gaps remain in understanding contact and mixing patterns and also in the advantages and disadvantages of data collection methods. We collected contact data from a middle school, with 7th and 8th grades, for one day using self-report contact logs and wireless sensors. The data were linked for students with unique initials, gender, and grade within the school. This paper presents the results of a comparison of two approaches to characterize school contact networks, wireless proximity sensors and self-report logs. Accounting for incomplete capture and lack of participation, we estimate that “sensor-detectable”, proximal contacts longer than 20 seconds during lunch and class-time occurred at 2 fold higher frequency than “self-reportable” talk/touch contacts. Overall, 55% of estimated talk-touch contacts were also sensor-detectable whereas only 15% of estimated sensor-detectable contacts were also talk-touch. Contacts detected by sensors and also in self-report logs had longer mean duration than contacts detected only by sensors (6.3 vs 2.4 minutes). During both lunch and class-time, sensor-detectable contacts demonstrated substantially less gender and grade assortativity than talk-touch contacts. Hallway contacts, which were ascertainable only by proximity sensors, were characterized by extremely high degree and short duration. We conclude that the use of wireless sensors and self-report logs provide complementary insight on in-school mixing patterns and contact frequency. PMID:27100090
Passive Sensor Materials Based on Liquid Crystals
2011-03-12
REPORT Passive Sensor Materials based on Liquid Crystals 14. ABSTRACT 16. SECURITY CLASSIFICATION OF: Research supported by this grant entitled “Passive...Sensor Materials Based on Liquid Crystals” revolved around an investigation of liquid crystalline materials for use in passive sensors for chemical... based on Liquid Crystals Report Title ABSTRACT Research supported by this grant entitled “Passive Sensor Materials Based on Liquid Crystals” revolved
Study of development and utilization of a multipurpose atmospheric corrosion sensor
NASA Technical Reports Server (NTRS)
Diwan, Ravinder M.; Raman, A.; Bhattacharya, P. K.
1994-01-01
There has been a critical need for analyzing various aspects of atmospheric corrosion and for the development of atmospheric corrosion microsensors. The project work has involved the following activities: (1) making of multielectrode corrosion monitors on dielectric substrates; (2) testing them in the laboratory for functional characteristics; (3) preparing a report on the state of the art of atmospheric corrosion sensor development around the world; and (4) corrosion testing of electrochemical changes of sensor specimens and related fog testing. The study included work on the subject of development and utilization of a multipurpose atmospheric corrosion sensor and this report is the annual report on work carried out on this research project. This has included studies on the development of sensors of two designs, stage 1 and stage 2, and with glass and alumina substrate, experimentation and development and characterization of the coating uniformity, aspects of corrosion monitoring, literature search on the corrosion sensors and their development. A state of the art report on atmospheric corrosion sensor development was prepared and submitted.
HEAT Sensor: Harsh Environment Adaptable Thermionic Sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Limb, Scott J.
2016-05-31
This document is the final report for the “HARSH ENVIRONMENT ADAPTABLE THERMIONIC SENSOR” project under NETL’s Crosscutting contract DE-FE0013062. This report addresses sensors that can be made with thermionic thin films along with the required high temperature hermetic packaging process. These sensors can be placed in harsh high temperature environments and potentially be wireless and self-powered.
DOT National Transportation Integrated Search
1999-11-01
The objective of this study is to determine the sensor survivability, accuracy and reliability of quartz-piezoelectric weigh-in-motion (WIM) sensors under actual traffic conditions in Connecticut's environment. This second interim report provides a s...
Sensor planning for moving targets
NASA Astrophysics Data System (ADS)
Musman, Scott A.; Lehner, Paul; Elsaesser, Chris
1994-10-01
Planning a search for moving ground targets is difficult for humans and computationally intractable. This paper describes a technique to solve such problems. The main idea is to combine probability of detection assessments with computational search heuristics to generate sensor plans which approximately maximize either the probability of detection or a user- specified knowledge function (e.g., determining the target's probable destination; locating the enemy tanks). In contrast to super computer-based moving target search planning, our technique has been implemented using workstation technology. The data structures generated by sensor planning can be used to evaluate sensor reports during plan execution. Our system revises its objective function with each sensor report, allowing the user to assess both the current situation as well as the expected value of future information. This capability is particularly useful in situations involving a high rate of sensor reporting, helping the user focus his attention on sensors reports most pertinent to current needs. Our planning approach is implemented in a three layer architecture. The layers are: mobility analysis, followed by sensor coverage analysis, and concluding with sensor plan analysis. It is possible using these layers to describe the physical, spatial, and temporal characteristics of a scenario in the first two layers, and customize the final analysis to specific intelligence objectives. The architecture also allows a user to customize operational parameters in each of the three major components of the system. As examples of these performance options, we briefly describe the mobility analysis and discuss issues affecting sensor plan analysis.
Thomas, Evan A; Barstow, Christina K; Rosa, Ghislaine; Majorin, Fiona; Clasen, Thomas
2013-01-01
Remotely reporting electronic sensors offer the potential to reduce bias in monitoring use of environmental health interventions. In the context of a five-month randomized controlled trial of household water filters and improved cookstoves in rural Rwanda, we collected data from intervention households on product compliance using (i) monthly surveys and direct observations by community health workers and environmental health officers, and (ii) sensor-equipped filters and cookstoves deployed for about two weeks in each household. The adoption rate interpreted by the sensors varied from the household reporting: 90.5% of households reported primarily using the intervention stove, while the sensors interpreted 73.2% use, and 96.5% of households reported using the intervention filter regularly, while the sensors interpreted no more than 90.2%. The sensor-collected data estimated use to be lower than conventionally collected data both for water filters (approximately 36% less water volume per day) and cookstoves (approximately 40% fewer uses per week). An evaluation of intrahousehold consistency in use suggests that households are not using their filters or stoves on an exclusive basis, and may be both drinking untreated water at times and using other stoves ("stove-stacking"). These results provide additional evidence that surveys and direct observation may exaggerate compliance with household-based environmental interventions.
2015-07-01
CMOS clean • Commercialization of the sensor is aided by this process as use of CMOS -clean commercial foundries will not be restricted Bench...AD_________________ Award Number: W81XWH-10-2-0040 TITLE: Advanced Sensors for TBI PRINCIPAL INVESTIGATOR: Bruce Lyeth, Ph.D. CONTRACTING...ABOVE ADDRESS. 1. REPORT DATE July 2015 2. REPORT TYPE Annual 3. DATES COVERED 1Jul2014 - 30Jun2015 4. TITLE AND SUBTITLE Advanced Sensors for TBI 5a
DOT National Transportation Integrated Search
2007-07-31
This report provides an evaluation of the current state of the SOCRATES sensor and its readiness for use as an operational sensor for active monitoring of aircraft wake turbulence. SOCRATES is a laser opto-acoustic array designed to passively detect ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Amanda S.; Brosha, Eric
This is a progress report for the demonstration of a prototype hydrogen sensor and electronics package. There are five tasks associated with this, and four have been completed as of August 2016: Station Demonstration and Site Recommendation, Order Sensor Equipment, Build Sensors, and Install Sensors. The final task to be completed is Sensor Demonstration and Data Analysis, and expected completion date is January 26, 2017. This progress report details each of the tasks and goes into detail about what is currently being worked on, along with the budget and planned work for July 27, 2016 to January 26, 2017.
Fan, Shicheng; Dan, Li; Meng, Lingju; Zheng, Wei; Elias, Anastasia; Wang, Xihua
2017-11-09
Flexible force/pressure sensors are of interest for academia and industry and have applications in wearable technologies. Most of such sensors on the market or reported in journal publications are based on the operation mechanism of probing capacitance or resistance changes of the materials under pressure. Recently, we reported the microelectromechanical (MEM) sensors based on a different mechanism: mechanical switches. Multiples of such MEM sensors can be integrated to achieve the same function of regular force/pressure sensors while having the advantages of ease of fabrication and long-term stability in operation. Herein, we report the dramatically improved response time (more than one order of magnitude) of these MEM sensors by employing eco-friendly nanomaterials-cellulose nanocrystals. For instance, the incorporation of polydimethysiloxane filled with cellulose nanocrystals shortened the response time of MEM sensors from sub-seconds to several milliseconds, leading to the detection of both diastolic and systolic pressures in the radial arterial blood pressure measurement. Comprehensive mechanical and electrical characterization of the materials and the devices reveal that greatly enhanced storage modulus and loss modulus play key roles in this improved response time. The demonstrated fast-response flexible sensors enabled continuous monitoring of heart rate and complex cardiovascular signals using pressure sensors for future wearable sensing platforms.
Fiber-optic sensors for aerospace electrical measurements - An update
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Rose, A. H.; Tang, D.; Day, G. W.
1991-01-01
The authors report the progress made on the development of aerospace current and voltage sensors which use fiber-optic and optical sensing heads. These sensors are presently designed to cover ac frequencies from 60 Hz to 20 kHz. The current sensor, based on the Faraday effect in optical fiber, is in advanced development after some initial testing. The emphasis is on packaging methods and ways to maintain consistent sensitivity with changes in temperature. The voltage sensor, utilizing the Pockels effect in a crystal, has excelled in temperature tests. The authors report on the development of these sensors. The authors also relate the technology used in the sensors, the results of evaluation, improvements being made, and the future direction of the work.
Fiber waveguide sensors for intelligent materials
NASA Technical Reports Server (NTRS)
Flax, A. R.; Claus, R. O.
1988-01-01
This report, an addendum to the six month report submitted to NASA Langley Research Center in December 1987, covers research performed by the Fiber and Electro-Optics Research Center (FEORC) at Virginia Tech for the NASA Langley Research Center, Grant NAG1-780, for the period from December 1987 to June 1988. This final report discusses the research performed in the following four areas as described in the proposal: Fabrication of Sensor Fibers Optimized for Embedding in Advanced Composites; Fabrication of Sensor Fiber with In-Line Splices and Evaluation via OTR methods; Modal Domain Optical Fiber Sensor Analysis; and Acoustic Fiber Waveguide Implementation.
Handheld Multi-Gas Meters Market Survey Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Gustavious; Wald-Hopkins, Mark David; Obrey, Stephen J.
2016-06-23
Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report ismore » based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.« less
A Prototype Tactile Sensor Array.
1982-09-15
Active Touch Sensing. Technical Report, MIT Artificial Inteligence Laboratory, 1981. (9] Larcombe, M. Carbon Fibre Tactile Sensors. Technical Report...thesis, Carnegie-Mellon University, 1981. [13] Purbrick, John A. A Force Transducer Employing Conductive Silicone Rubber. Technical Report, MIT Artificial
Zafar, Sufi; D'Emic, Christopher; Jagtiani, Ashish; Kratschmer, Ernst; Miao, Xin; Zhu, Yu; Mo, Renee; Sosa, Norma; Hamann, Hendrik F; Shahidi, Ghavam; Riel, Heike
2018-06-22
Silicon nanowire field effect transistor (FET) sensors have demonstrated their ability for rapid and label free detection of proteins, nucleotide sequences, and viruses at ultralow concentrations with the potential to be a transformative diagnostic technology. Their nanoscale size gives them their unique ultralow detection ability but also makes their fabrication challenging with large sensor to sensor variations, thus limiting their commercial applications. In this work, a combined approach of nanofabrication, device simulation, materials and electrical characterization is applied towards identifying and improving fabrication steps that induce sensor to sensor variations. An enhanced complementary metal-oxide-semiconductor (CMOS) compatible process for fabricating silicon nanowire FET sensors is demonstrated. Nanowire (30 nm width) FETs with aqueous solution as gates are shown to have the Nernst limit sub-threshold swing SS = 60 mV/decade with ~1.7% variations, whereas literature values for SS are ≥ 80 mV/decade with larger (>10 times) variations. Also, their threshold voltage variations are significantly (~3 times) reduced, compared to literature values. Furthermore, these improved FETs have significantly reduced drain current hysteresis (~0.6 mV) and enhanced on-current to off-current ratios (~10 6 ). These improvements resulted in nanowire FET sensors with lowest (~3%) reported sensor to sensor variations, compared to literature studies. Also, these improved nanowire sensors have the highest reported sensitivity and enhanced signal to noise ratio with the lowest reported defect density of 1x10 18 eV -1 cm -3 in comparison to literature data. In summary, this work brings the nanowire sensor technology a step closer to commercial products for early diagnosis and monitoring of diseases.
Skylab program earth resources experiment package sensor performance evaluation, volume 1, (S190A)
NASA Technical Reports Server (NTRS)
Kenney, G. P.
1975-01-01
The results of S190A sensor performance evaluation are summarized based on data presented by all contributors to the sensor performance evaluation interim reports. Techniques used in sensor performance evaluation are discussed. Topics discussed include: performance degradation identified during the Skylab missions, S190A and EREP system anomalies that affected S190A performance, and the performance achieved, in terms of pertinent S190A parameters. Additional analyses include final performance analyses completed after submittal of the SL4 interim sensor performance evaluation reports, including completion of detailed analyses of basic performance parameters initiated during the interim report periods and consolidation analyses to reduce independent mission data (SL2, SL3, and SL4) to determine overall performance realized during all three Skylab missions.
Integration of Nanostructures into Microsensor Devices on Whole Wafers
NASA Technical Reports Server (NTRS)
Biaggi-Labiosa, Azlin M.; Evans, Laura J.; Berger, Gordon M.; Hunter, Gary W.
2015-01-01
Chemical sensors are used in a wide variety of applications, such as environmental monitoring, fire detection, emission monitoring, and health monitoring. The fabrication of chemical sensors involving nanostructured materials holds the potential for the development of sensor systems with unique properties and improved performance. However, the fabrication and processing of nanostructures for sensor applications currently are limited in the ability to control their location on the sensor, which in turn hinders the progress for batch fabrication. This report discusses the advantages of using nanomaterials in sensor designs, some of the challenges encountered with the integration of nanostructures into microsensor / devices, and then briefly describes different methods attempted by other groups to address this issue. Finally, this report will describe how our approach for the controlled alignment of nanostructures onto a sensor platform was applied to demonstrate an approach for the mass production of sensors with nanostructures.
Park, Jung Jin; Hyun, Woo Jin; Mun, Sung Cik; Park, Yong Tae; Park, O Ok
2015-03-25
Because of their outstanding electrical and mechanical properties, graphene strain sensors have attracted extensive attention for electronic applications in virtual reality, robotics, medical diagnostics, and healthcare. Although several strain sensors based on graphene have been reported, the stretchability and sensitivity of these sensors remain limited, and also there is a pressing need to develop a practical fabrication process. This paper reports the fabrication and characterization of new types of graphene strain sensors based on stretchable yarns. Highly stretchable, sensitive, and wearable sensors are realized by a layer-by-layer assembly method that is simple, low-cost, scalable, and solution-processable. Because of the yarn structures, these sensors exhibit high stretchability (up to 150%) and versatility, and can detect both large- and small-scale human motions. For this study, wearable electronics are fabricated with implanted sensors that can monitor diverse human motions, including joint movement, phonation, swallowing, and breathing.
2012-06-27
notes and team orienteering functions. Data collection with the MP system at the former Camp Beale, CA is shown in Figure 5- 2 (right). 5.3.3...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --12-9424 TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO...CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2 . REPORT TYPE1. REPORT DATE (DD
1987-06-01
commercial products. · OP -- Typical cutout at a plumbiinc location where an automated monitoring system has bv :• installed. The sensor used with the...This report provides a description of commercially available sensors , instruments, and ADP equipment that may be selected to fully automate...automated. The automated plumbline monitoring system includes up to twelve sensors , repeaters, a system controller, and a printer. The system may
“Are you sure?”: Lapses in Self-Reported Activities Among Healthy Older Adults Reporting Online
Wild, Katherine V.; Mattek, Nora; Austin, Daniel; Kaye, Jeffrey A.
2015-01-01
Accurate retrospective reporting of activities and symptoms has been shown to be problematic for older adults, yet standard clinical care relies on self-reports to aid in assessment and management. Our aim was to examine the relationship between self-report and sensor-based measures of activity. We administered an online activity survey to participants in our ongoing longitudinal study of in-home ubiquitous monitoring. We found a wide range of accuracy when comparing self-report with time-stamped sensor data. Of the 95 participants who completed the two-hour activity log, nearly one quarter did not complete the task in a way that could potentially be compared with sensor data. Where comparisons were possible, agreement between self-reported and sensor-based activity was achieved by a minority of participants. The findings suggest that capture of real time events with unobtrusive activity monitoring may be a more reliable approach to describing behaviors patterns and meaningful changes in older adults. PMID:25669877
Multivariable bio-inspired photonic sensors for non-condensable gases
NASA Astrophysics Data System (ADS)
Potyrailo, Radislav A.; Karker, Nicholas; Carpenter, Michael A.; Minnick, Andrew
2018-02-01
Existing gas sensors often lose their measurement accuracy in practical field applications. To mitigate this significant problem, here, we report a demonstration of fabricated multivariable photonic sensors inspired by a known nanostructure of Morpho butterfly scales for detection of exemplary non-condensable gases such as H2, CO, and CO2. We fabricated bio-inspired nanostructures using conventional photolithography and chemical etching and detected individual gases that were difficult or unrealistic to detect using natural Morpho nanostructures. Such bio-inspired gas sensors are the critical step in the development of new sensors with improved accuracy for diverse operational scenarios. While this report is our initial demonstration of responses of fabricated multivariable sensors to individual gases in pristine laboratory conditions, it is a significant milestone in understanding the next steps toward field tests and practical applications of these sensors.
Characterization Test Report for the Mnemonics-UCS Wireless Surface Acoustic Wave Sensor System
NASA Technical Reports Server (NTRS)
Duncan, Joshua J.; Youngquist, Robert C.
2013-01-01
The scope of this testing includes the Surface Acoustic Wave Sensor System delivered to KSC: two interrogator (transceiver) systems, four temperature sensors, with wooden mounting blocks, two antennas, two power supplies, network cables, and analysis software. Also included are a number of additional temperature sensors and newly-developed hydrogen sensors
Guimarães, Dayan Adionel; Sakai, Lucas Jun; Alberti, Antonio Marcos; de Souza, Rausley Adriano Amaral
2016-09-20
In this paper, a simple and flexible method for increasing the lifetime of fixed or mobile wireless sensor networks is proposed. Based on past residual energy information reported by the sensor nodes, the sink node or another central node dynamically optimizes the communication activity levels of the sensor nodes to save energy without sacrificing the data throughput. The activity levels are defined to represent portions of time or time-frequency slots in a frame, during which the sensor nodes are scheduled to communicate with the sink node to report sensory measurements. Besides node mobility, it is considered that sensors' batteries may be recharged via a wireless power transmission or equivalent energy harvesting scheme, bringing to the optimization problem an even more dynamic character. We report large increased lifetimes over the non-optimized network and comparable or even larger lifetime improvements with respect to an idealized greedy algorithm that uses both the real-time channel state and the residual energy information.
Development and evaluation of fiber optic sensors : final report.
DOT National Transportation Integrated Search
2003-05-01
This study investigated the feasibility of using fiber optic sensors to capture traffic data. Funding from the : study was used to develop a prototype sensor using fiber Bragg gratings (FBG) technology. The sensor was : tested on a high volume portla...
NASA Technical Reports Server (NTRS)
Hovis, W.; Smith, D.; Mcculloch, A.; Goldberg, I. L.; Ostrow, H.; Seidenberg, B.
1973-01-01
Examples of contamination of sensors from various sources during space missions are presented. Design precautions to provide access to optical surfaces and venting of outgassing products are recommended as methods for coping with contamination. The effects of the sensor materials on sensor contamination are analyzed. Actions to be taken during transportation, storage, and testing of sensors to avoid contamination are discussed.
Final Report: Sensorpedia Phase 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorman, Bryan L; Resseguie, David R
2011-02-01
This report is a summary of the Oak Ridge National Laboratory s (ORNL s) Phase 3 development of Sensorpedia, a sensor information sharing platform. Sensorpedia is ORNL s Wikipedia for Sensors. The overall goal of Sensorpedia is to enable global scale sensor information sharing for scientific research, national security and defense, public health and safety, emergency preparedness and response, and general community awareness and outreach.
Ponzoni, Andrea; Comini, Elisabetta; Concina, Isabella; Ferroni, Matteo; Falasconi, Matteo; Gobbi, Emanuela; Sberveglieri, Veronica; Sberveglieri, Giorgio
2012-01-01
In this work we report on metal oxide (MOX) based gas sensors, presenting the work done at the SENSOR laboratory of the CNR-IDASC and University of Brescia, Italy since the 80s up to the latest results achieved in recent times. In particular we report the strategies followed at SENSOR during these 30 years to increase the performance of MOX sensors through the development of different preparation techniques, from Rheotaxial Growth Thermal Oxidation (RGTO) to nanowire technology to address sensitivity and stability, and the development of electronic nose systems and pattern recognition techniques to address selectivity. We will show the obtained achievement in the context of selected applications such as safety and security and food quality control. PMID:23235445
NASA Astrophysics Data System (ADS)
Hayami, Hajime; Takehara, Hiroaki; Nagata, Kengo; Haruta, Makito; Noda, Toshihiko; Sasagawa, Kiyotaka; Tokuda, Takashi; Ohta, Jun
2016-04-01
Intra body communication technology allows the fabrication of compact implantable biomedical sensors compared with RF wireless technology. In this paper, we report the fabrication of an implantable image sensor of 625 µm width and 830 µm length and the demonstration of wireless image-data transmission through a brain tissue of a living mouse. The sensor was designed to transmit output signals of pixel values by pulse width modulation (PWM). The PWM signals from the sensor transmitted through a brain tissue were detected by a receiver electrode. Wireless data transmission of a two-dimensional image was successfully demonstrated in a living mouse brain. The technique reported here is expected to provide useful methods of data transmission using micro sized implantable biomedical sensors.
Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide.
Duvall, Rachelle M; Long, Russell W; Beaver, Melinda R; Kronmiller, Keith G; Wheeler, Michael L; Szykman, James J
2016-10-13
This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in Houston, Texas and Denver, Colorado, under the umbrella of the NASA-led DISCOVER-AQ Earth Venture Mission. Measurements were focused on ozone (O₃) and nitrogen dioxide (NO₂). The performance evaluation showed that the CairClip O₃/NO₂ sensor provided a consistent measurement response to that of reference monitors (r² = 0.79 in Houston; r² = 0.72 in Denver) whereas the CairClip NO₂ sensor measurements showed no agreement to reference measurements. The CairClip O₃/NO₂ sensor data from the citizen science sites compared favorably to measurements at nearby reference monitoring sites. This study provides important information on data quality from low-cost sensor technologies and is one of few studies that reports sensor data collected directly by citizen scientists.
Handheld Multi-Gas Meters Assessment Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Gustavious; Wald-Hopkins, Mark David; Obrey, Stephen J.
2016-06-27
Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria andmore » scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.« less
A Carbon Nanotube Reporter of miRNA Hybridization Events In Vivo
Harvey, Jackson D.; Jena, Prakrit V.; Baker, Hanan A.; Zerze, Gül H.; Williams, Ryan M.; Galassi, Thomas V.; Roxbury, Daniel; Mittal, Jeetain
2017-01-01
MicroRNAs and other small oligonucleotides in biofluids are promising disease biomarkers, yet conventional assays require complex processing steps that are unsuitable for point-of-care testing or for implantable or wearable sensors. Single-walled carbon nanotubes are an ideal material for implantable sensors, owing to their emission in the near-infrared spectral region, photostability and exquisite sensitivity. Here, we report an engineered carbon-nanotube-based sensor capable of real-time optical quantification of hybridization events of microRNA and other oligonucleotides. The mechanism of the sensor arises from competitive effects between displacement of both oligonucleotide charge groups and water from the nanotube surface, which result in a solvatochromism-like response. The sensor, which allows for detection via single-molecule sensor elements and for multiplexing by using multiple nanotube chiralities, can monitor toehold-based strand-displacement events, which reverse the sensor response and regenerate the sensor complex. We also show that the sensor functions in whole urine and serum, and can non-invasively measure DNA and microRNA after implantation in live mice. PMID:28845337
Modeling Sensor Reliability in Fault Diagnosis Based on Evidence Theory
Yuan, Kaijuan; Xiao, Fuyuan; Fei, Liguo; Kang, Bingyi; Deng, Yong
2016-01-01
Sensor data fusion plays an important role in fault diagnosis. Dempster–Shafer (D-R) evidence theory is widely used in fault diagnosis, since it is efficient to combine evidence from different sensors. However, under the situation where the evidence highly conflicts, it may obtain a counterintuitive result. To address the issue, a new method is proposed in this paper. Not only the statistic sensor reliability, but also the dynamic sensor reliability are taken into consideration. The evidence distance function and the belief entropy are combined to obtain the dynamic reliability of each sensor report. A weighted averaging method is adopted to modify the conflict evidence by assigning different weights to evidence according to sensor reliability. The proposed method has better performance in conflict management and fault diagnosis due to the fact that the information volume of each sensor report is taken into consideration. An application in fault diagnosis based on sensor fusion is illustrated to show the efficiency of the proposed method. The results show that the proposed method improves the accuracy of fault diagnosis from 81.19% to 89.48% compared to the existing methods. PMID:26797611
A Carbon Nanotube Reporter of miRNA Hybridization Events In Vivo.
Harvey, Jackson D; Jena, Prakrit V; Baker, Hanan A; Zerze, Gül H; Williams, Ryan M; Galassi, Thomas V; Roxbury, Daniel; Mittal, Jeetain; Heller, Daniel A
2017-01-01
MicroRNAs and other small oligonucleotides in biofluids are promising disease biomarkers, yet conventional assays require complex processing steps that are unsuitable for point-of-care testing or for implantable or wearable sensors. Single-walled carbon nanotubes are an ideal material for implantable sensors, owing to their emission in the near-infrared spectral region, photostability and exquisite sensitivity. Here, we report an engineered carbon-nanotube-based sensor capable of real-time optical quantification of hybridization events of microRNA and other oligonucleotides. The mechanism of the sensor arises from competitive effects between displacement of both oligonucleotide charge groups and water from the nanotube surface, which result in a solvatochromism-like response. The sensor, which allows for detection via single-molecule sensor elements and for multiplexing by using multiple nanotube chiralities, can monitor toehold-based strand-displacement events, which reverse the sensor response and regenerate the sensor complex. We also show that the sensor functions in whole urine and serum, and can non-invasively measure DNA and microRNA after implantation in live mice.
Advances in Classification Methods for Military Munitions Response
2010-12-01
Response Herb Nelson Objective of the Course Provide an update on the sensors , methods, and status of the classification of military munitions...advanced EMI sensors 2Advances in Classification - Introduction Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the...Electromagnetics (EM): Fundamentals and Parameter Extraction Stephen Billings EM Module Outline ● EMI Fundamentals How EMI sensors work and what they measure
Zinc oxide inverse opal enzymatic biosensor
NASA Astrophysics Data System (ADS)
You, Xueqiu; Pikul, James H.; King, William P.; Pak, James J.
2013-06-01
We report ZnO inverse opal- and nanowire (NW)-based enzymatic glucose biosensors with extended linear detection ranges. The ZnO inverse opal sensors have 0.01-18 mM linear detection range, which is 2.5 times greater than that of ZnO NW sensors and 1.5 times greater than that of other reported ZnO sensors. This larger range is because of reduced glucose diffusivity through the inverse opal geometry. The ZnO inverse opal sensors have an average sensitivity of 22.5 μA/(mM cm2), which diminished by 10% after 35 days, are more stable than ZnO NW sensors whose sensitivity decreased by 10% after 7 days.
Sonic CPT Probing in Support of DNAPL Characterization
2000-11-21
directed at developing advanced sensors for delivery by the cone penetrometer. To accommodate these new sensors , probe sizes have increased (from 1.44-in...capability of the CPT, a sonic vibratory system was integrated with conventional CPT to advance cone penetrometer sensor packages past currently attainable...Sonic, Cone Penetrometer, Site Characterization, Fluorescense, Sensor , Shock Hardened Sensors , Geoprobe• 17. SECURITY CLASSIFICATION OF REPORT
1990-12-01
Temperature Distance Sensors -. ...................... 188 Start Transient 4.5-7 Distance Sensor Signal as a Function of Speed...189 4.5-8 Distance Sensor Signal as a Function of Speed ......................................... 190 4.5-9 Cryogenic Operation of...Distance Sensors at 72,000 RPM ........................ 192 Steady State 4.5-10 Cryogenic Operation of Distance Sensor Through Start
2014-03-31
Network Connectivity Assessment via Local Data Exchange for Underwater Acoustic Sensor Networks M.M. Asadi H. Mahboubi A...2014 Global Network Connectivity Assessment via Local Data Exchange for Underwater Acoustic Sensor Networks Contract Report # AMBUSH.1.1 Contract...pi j /= 0. The sensor network considered in this work is composed of underwater sensors , which use acoustic waves for
Smieszek, Timo; Castell, Stefanie; Barrat, Alain; Cattuto, Ciro; White, Peter J; Krause, Gérard
2016-07-22
Studies measuring contact networks have helped to improve our understanding of infectious disease transmission. However, several methodological issues are still unresolved, such as which method of contact measurement is the most valid. Further, complete network analysis requires data from most, ideally all, members of a network and, to achieve this, acceptance of the measurement method. We aimed at investigating measurement error by comparing two methods of contact measurement - paper diaries vs. wearable proximity sensors - that were applied concurrently to the same population, and we measured acceptability. We investigated the contact network of one day of an epidemiology conference in September 2014. Seventy-six participants wore proximity sensors throughout the day while concurrently recording their contacts with other study participants in a paper-diary; they also reported on method acceptability. There were 329 contact reports in the paper diaries, corresponding to 199 contacts, of which 130 were noted by both parties. The sensors recorded 316 contacts, which would have resulted in 632 contact reports if there had been perfect concordance in recording. We estimated the probabilities that a contact was reported in a diary as: P = 72 % for <5 min contact duration (significantly lower than the following, p < 0.05), P = 86 % for 5-15 min, P = 89 % for 15-60 min, and P = 94 % for >60 min. The sets of sensor-measured and self-reported contacts had a large intersection, but neither was a subset of the other. Participants' aggregated contact duration was mostly substantially longer in the diary data than in the sensor data. Twenty percent of respondents (>1 reported contact) stated that filling in the diary was too much work, 25 % of respondents reported difficulties in remembering contacts, and 93 % were comfortable having their conference contacts measured by sensors. Reporting and recording were not complete; reporting was particularly incomplete for contacts <5 min. The types of contact that both methods are capable of detecting are partly different. Participants appear to have overestimated the duration of their contacts. Conducting a study with diaries or wearable sensors was acceptable to and mostly easily done by participants. Both methods can be applied meaningfully if their specific limitations are considered and incompleteness is accounted for.
Report on the Audit of Unattended Ground Sensor Systems
1991-02-26
This final report on the Audit of Unattended Ground Sensor Systems is for your information and use. Comments on the draft were considered in...preparing the final report and changes have been made where appropriate. We performed the audit from February through August 1990. The objective was to
77 FR 19074 - Airworthiness Directives; DASSAULT AVIATION Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-30
... reports of fuel leakage from a defective fuel high-level sensor located in the wing front spar. This AD requires inspecting to determine fuel quantity sensors part numbers and replacing of certain fuel quantity sensors with new fuel quantity sensors. We are issuing this AD to prevent internal fuel leakage with...
DOT National Transportation Integrated Search
2016-08-01
This two-pronged study evaluated the performance of commercial off-the-shelf (COTS) micro-electromechanical sensors and systems (MEMS) embedded in concrete pavement (Final Report Volume I) and developed a wireless MEMS multifunctional sensor system f...
Development of the smartphone-based colorimetry for multi-analyte sensing arrays.
Hong, Jong Il; Chang, Byoung-Yong
2014-05-21
Here we report development of a smartphone app (application) that digitizes the colours of a colorimetric sensor array. A conventional colorimetric sensor array consists of multiple paper-based sensors, and reports the detection results in terms of colour change. Evaluation of the colour changes is normally done by the naked eye, which may cause uncertainties due to personal subjectivity and the surrounding conditions. Solutions have been particularly sought in smartphones as they are capable of spectrometric functions. Our report specifically focuses on development of a practical app for immediate point-of-care (POC) multi-analyte sensing without additional devices. First, the individual positions of the sensors are automatically identified by the smartphone; second, the colours measured at each sensor are digitized based on a correction algorithm; and third, the corrected colours are converted to concentration values by pre-loaded calibration curves. All through these sequential processes, the sensor array taken in a smartphone snapshot undergoes laboratory-level spectrometry. The advantages of inexpensive and convenient paper-based colorimetry and the ubiquitous smartphone are tied to achieve a ready-to-go POC diagnosis.
A Large Area Tactile Sensor Patch Based on Commercial Force Sensors
Vidal-Verdú, Fernando; Barquero, Maria Jose; Castellanos-Ramos, Julián; Navas-González, Rafael; Sánchez, Jose Antonio; Serón, Javier; García-Cerezo, Alfonso
2011-01-01
This paper reports the design of a tactile sensor patch to cover large areas of robots and machines that interact with human beings. Many devices have been proposed to meet such a demand. These realizations are mostly custom-built or developed in the lab. The sensor of this paper is implemented with commercial force sensors. This has the benefit of a more foreseeable response of the sensor if its behavior is understood as the aggregation of readings from all the individual force sensors in the array. A few reported large area tactile sensors are also based on commercial sensors. However, the one in this paper is the first of this kind based on the use of polymeric commercial force sensing resistors (FSR) as unit elements of the array or tactels, which results in a robust sensor. The paper discusses design issues related to some necessary modifications of the force sensor, its assembly in an array, and the signal conditioning. The patch has 16 × 9 force sensors mounted on a flexible printed circuit board with a spatial resolution of 18.5 mm. The force range of a tactel is 6 N and its sensitivity is 0.6 V/N. The array is read at a rate of 78 frames per second. Finally, two simple application examples are also carried out with the sensor mounted on the forearm of a rescue robot that communicates with the sensor through a CAN bus. PMID:22163910
NASA Technical Reports Server (NTRS)
Dhawan, R.; Gunther, M. F.; Claus, R. O.
1991-01-01
Quantitative measurements of the in-plane particle displacement components of ultrasonic surface acoustic wave fields using extrinsic Fizeau fiber interferometric (EFFI) sensors are reported. Wave propagation in materials and the fiber sensor elements are briefly discussed. Calibrated experimental results obtained for simulated acoustic emission events on homogeneous metal test specimens are reported and compared to previous results obtained using piezoelectric transducers.
Robust Multi Sensor Classification via Jointly Sparse Representation
2016-03-14
rank, sensor network, dictionary learning REPORT DOCUMENTATION PAGE 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 10. SPONSOR/MONITOR’S ACRONYM(S) ARO 8...with ultrafast laser pulses, Optics Express, (04 2015): 10521. doi: Xiaoxia Sun, Nasser M. Nasrabadi, Trac D. Tran. Task-Driven Dictionary Learning...in dictionary design, compressed sensors design, and optimization in sparse recovery also helps. We are able to advance the state of the art
SFO wake turbulence measurement system : sensors and data descriptions
DOT National Transportation Integrated Search
2006-10-01
This report addresses aspects of an extensive aircraft wake turbulence measurement program conducted at San Francisco : International Airport (SFO) over a two-year period. Specifically, this report describes the sensors used for data collection and t...
NASA Astrophysics Data System (ADS)
Datta, Kunal; Rushi, Arti; Ghosh, Prasanta; Shirsat, Mahendra
2018-05-01
We report sensors for detection of ethyl alcohol, a prominent volatile organic compound (VOC). Single walled carbon nanotubes were selected as main sensing backbone. As efficiency of sensor is dependent upon the choice of sensing materials, the performances of conducting polymer and porphyrin based sensors were compared. Chemiresistive sensing modality was adopted to observe the performance of sensors. It has been found that porphyrin based sensor shows higher affinity towards ethyl alcohol.
NASA Technical Reports Server (NTRS)
Poppel, G. L.; Marple, D. T. F.; Kingsley, J. D.
1981-01-01
Analyses and the design, fabrication, and testing of an optical tip clearance sensor with intended application in aircraft propulsion control systems are reported. The design of a sensor test rig, evaluation of optical sensor components at elevated temperatures, sensor design principles, sensor test results at room temperature, and estimations of sensor accuracy at temperatures of an aircraft engine environment are discussed. Room temperature testing indicated possible measurement accuracies of less than 12.7 microns (0.5 mils). Ways to improve performance at engine operating temperatures are recommended. The potential of this tip clearance sensor is assessed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, Ken D.; Quinn, Edward L.; Mauck, Jerry L.
The nuclear industry has been slow to incorporate digital sensor technology into nuclear plant designs due to concerns with digital qualification issues. However, the benefits of digital sensor technology for nuclear plant instrumentation are substantial in terms of accuracy and reliability. This paper, which refers to a final report issued in 2013, demonstrates these benefits in direct comparisons of digital and analog sensor applications. Improved accuracy results from the superior operating characteristics of digital sensors. These include improvements in sensor accuracy and drift and other related parameters which reduce total loop uncertainty and thereby increase safety and operating margins. Anmore » example instrument loop uncertainty calculation for a pressure sensor application is presented to illustrate these improvements. This is a side-by-side comparison of the instrument loop uncertainty for both an analog and a digital sensor in the same pressure measurement application. Similarly, improved sensor reliability is illustrated with a sample calculation for determining the probability of failure on demand, an industry standard reliability measure. This looks at equivalent analog and digital temperature sensors to draw the comparison. The results confirm substantial reliability improvement with the digital sensor, due in large part to ability to continuously monitor the health of a digital sensor such that problems can be immediately identified and corrected. This greatly reduces the likelihood of a latent failure condition of the sensor at the time of a design basis event. Notwithstanding the benefits of digital sensors, there are certain qualification issues that are inherent with digital technology and these are described in the report. One major qualification impediment for digital sensor implementation is software common cause failure (SCCF).« less
Overview of Fiber-Optical Sensors
NASA Technical Reports Server (NTRS)
Depaula, Ramon P.; Moore, Emery L.
1987-01-01
Design, development, and sensitivity of sensors using fiber optics reviewed. State-of-the-art and probable future developments of sensors using fiber optics described in report including references to work in field. Serves to update previously published surveys. Systems incorporating fiber-optic sensors used in medical diagnosis, navigation, robotics, sonar, power industry, and industrial controls.
Soil water sensors for irrigation scheduling:Can they deliver a management allowed depletion?
USDA-ARS?s Scientific Manuscript database
Soil water sensors are widely marketed in the farming sector as aids for irrigation scheduling. Sensors report either volumetric water content (theta-v, m**3 m**-3) or soil water potential, with theta-v sensors being by far the most common. To obtain yield and quality goals, irrigations are schedule...
NASA Technical Reports Server (NTRS)
Mckee, James W.
1988-01-01
This final report describes the accomplishments of the General Purpose Intelligent Sensor Interface task of the Applications of Artificial Intelligence to Space Station grant for the period from October 1, 1987 through September 30, 1988. Portions of the First Biannual Report not revised will not be included but only referenced. The goal is to develop an intelligent sensor system that will simplify the design and development of expert systems using sensors of the physical phenomena as a source of data. This research will concentrate on the integration of image processing sensors and voice processing sensors with a computer designed for expert system development. The result of this research will be the design and documentation of a system in which the user will not need to be an expert in such areas as image processing algorithms, local area networks, image processor hardware selection or interfacing, television camera selection, voice recognition hardware selection, or analog signal processing. The user will be able to access data from video or voice sensors through standard LISP statements without any need to know about the sensor hardware or software.
RSA/Legacy Wind Sensor Comparison. Part 2; Eastern Range
NASA Technical Reports Server (NTRS)
Short, David A.; Wheeler, Mark M.
2006-01-01
This report describes a comparison of data from ultrasonic and propeller-and-vane anemometers on 5 wind towers at Kennedy Space Center and Cape Canaveral Air Force Station. The ultrasonic sensors are scheduled to replace the Legacy propeller-and-vane sensors under the Range Standardization and Automation (RSA) program. Because previous studies have noted differences between peak wind speeds reported by mechanical and ultrasonic wind sensors, the latter having no moving parts, the 30th and 45th Weather Squadrons wanted to understand possible differences between the two sensor types. The period-of-record was 13-30 May 2005, A total of 357,626 readings of 1-minute average and peak wind speed/direction from each sensor type were used. Statistics of differences in speed and direction were used to identify 15 out of 19 RSA sensors having the most consistent performance, with respect to the Legacy sensors. RSA average wind speed data from these 15 showed a small positive bias of 0.38 kts. A slightly larger positive bias of 0.94 kts was found in the RSA peak wind speed.
A Scheme to Smooth Aggregated Traffic from Sensors with Periodic Reports
Oh, Sungmin; Jang, Ju Wook
2017-01-01
The possibility of smoothing aggregated traffic from sensors with varying reporting periods and frame sizes to be carried on an access link is investigated. A straightforward optimization would take O(pn) time, whereas our heuristic scheme takes O(np) time where n, p denote the number of sensors and size of periods, respectively. Our heuristic scheme performs local optimization sensor by sensor, starting with the smallest to largest periods. This is based on an observation that sensors with large offsets have more choices in offsets to avoid traffic peaks than the sensors with smaller periods. A MATLAB simulation shows that our scheme excels the known scheme by M. Grenier et al. in a similar situation (aggregating periodic traffic in a controller area network) for almost all possible permutations. The performance of our scheme is very close to the straightforward optimization, which compares all possible permutations. We expect that our scheme would greatly contribute in smoothing the traffic from an ever-increasing number of IoT sensors to the gateway, reducing the burden on the access link to the Internet. PMID:28273831
Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide
Duvall, Rachelle M.; Long, Russell W.; Beaver, Melinda R.; Kronmiller, Keith G.; Wheeler, Michael L.; Szykman, James J.
2016-01-01
This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in Houston, Texas and Denver, Colorado, under the umbrella of the NASA-led DISCOVER-AQ Earth Venture Mission. Measurements were focused on ozone (O3) and nitrogen dioxide (NO2). The performance evaluation showed that the CairClip O3/NO2 sensor provided a consistent measurement response to that of reference monitors (r2 = 0.79 in Houston; r2 = 0.72 in Denver) whereas the CairClip NO2 sensor measurements showed no agreement to reference measurements. The CairClip O3/NO2 sensor data from the citizen science sites compared favorably to measurements at nearby reference monitoring sites. This study provides important information on data quality from low-cost sensor technologies and is one of few studies that reports sensor data collected directly by citizen scientists. PMID:27754370
A Scheme to Smooth Aggregated Traffic from Sensors with Periodic Reports.
Oh, Sungmin; Jang, Ju Wook
2017-03-03
The possibility of smoothing aggregated traffic from sensors with varying reporting periods and frame sizes to be carried on an access link is investigated. A straightforward optimization would take O(pn) time, whereas our heuristic scheme takes O(np) time where n, p denote the number of sensors and size of periods, respectively. Our heuristic scheme performs local optimization sensor by sensor, starting with the smallest to largest periods. This is based on an observation that sensors with large offsets have more choices in offsets to avoid traffic peaks than the sensors with smaller periods. A MATLAB simulation shows that our scheme excels the known scheme by M. Grenier et al. in a similar situation (aggregating periodic traffic in a controller area network) for almost all possible permutations. The performance of our scheme is very close to the straightforward optimization, which compares all possible permutations. We expect that our scheme would greatly contribute in smoothing the traffic from an ever-increasing number of IoT sensors to the gateway, reducing the burden on the access link to the Internet.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artuso, M.; et al.,
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In additionmore » the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges.« less
Time-optimum packet scheduling for many-to-one routing in wireless sensor networks
Song, W.-Z.; Yuan, F.; LaHusen, R.; Shirazi, B.
2007-01-01
This paper studies the wireless sensor networks (WSN) application scenario with periodical traffic from all sensors to a sink. We present a time-optimum and energy-efficient packet scheduling algorithm and its distributed implementation. We first give a general many-to-one packet scheduling algorithm for wireless networks, and then prove that it is time-optimum and costs [image omitted], N(u0)-1) time slots, assuming each node reports one unit of data in each round. Here [image omitted] is the total number of sensors, while [image omitted] denotes the number of sensors in a sink's largest branch subtree. With a few adjustments, we then show that our algorithm also achieves time-optimum scheduling in heterogeneous scenarios, where each sensor reports a heterogeneous amount of data in each round. Then we give a distributed implementation to let each node calculate its duty-cycle locally and maximize efficiency globally. In this packet-scheduling algorithm, each node goes to sleep whenever it is not transceiving, so that the energy waste of idle listening is also mitigated. Finally, simulations are conducted to evaluate network performance using the Qualnet simulator. Among other contributions, our study also identifies the maximum reporting frequency that a deployed sensor network can handle.
Micro packaged MEMS pressure sensor for intracranial pressure measurement
NASA Astrophysics Data System (ADS)
Xiong, Liu; Yan, Yao; Jiahao, Ma; Yanhang, Zhang; Qian, Wang; Zhaohua, Zhang; Tianling, Ren
2015-06-01
This paper presents a micro packaged MEMS pressure sensor for intracranial pressure measurement which belongs to BioMEMS. It can be used in lumbar puncture surgery to measure intracranial pressure. Miniaturization is key for lumbar puncture surgery because the sensor must be small enough to allow it be placed in the reagent chamber of the lumbar puncture needle. The size of the sensor is decided by the size of the sensor chip and package. Our sensor chip is based on silicon piezoresistive effect and the size is 400 × 400 μm2. It is much smaller than the reported polymer intracranial pressure sensors such as liquid crystal polymer sensors. In terms of package, the traditional dual in-line package obviously could not match the size need, the minimal size of recently reported MEMS-based intracranial pressure sensors after packaging is 10 × 10 mm2. In this work, we are the first to introduce a quad flat no-lead package as the package form of piezoresistive intracranial pressure sensors, the whole size of the sensor is minimized to only 3 × 3 mm2. Considering the liquid measurement environment, the sensor is gummed and waterproof performance is tested; the sensitivity of the sensor is 0.9 × 10-2 mV/kPa. Project supported by the National Natural Science Foundation of China (Nos. 61025021, 61434001), and the ‘Thousands Talents’ Program for Pioneer Researchers and Its Innovation Team, China.
Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring.
Sartiano, Demetrio; Sales, Salvador
2017-12-13
The aim of this paper is to report the design of a low-cost plastic optical fiber (POF) pressure sensor, embedded in a mattress. We report the design of a multipoint sensor, a cheap alternative to the most common fiber sensors. The sensor is implemented using Arduino board, standard LEDs for optical communication in POF (λ = 645 nm) and a silicon light sensor. The Super ESKA ® plastic fibers were used to implement the fiber intensity sensor, arranged in a 4 × 4 matrix. During the breathing cycles, the force transmitted from the lungs to the thorax is in the order of tens of Newtons, and the respiration rate is of one breath every 2-5 s (0.2-0.5 Hz). The sensor has a resolution of force applied on a single point of 2.2-4.5%/N on the normalized voltage output, and a bandwidth of 10 Hz, it is then suitable to monitor the respiration movements. Another issue to be addressed is the presence of hysteresis over load cycles. The sensor was loaded cyclically to estimate the drift of the system, and the hysteresis was found to be negligible.
Explosive Infrasonic Events: Sensor Comparison Experiment (SCE)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schnurr, J. M.; Garces, M.; Rodgers, A. J.
SCE (sensor comparison experiment) 1 through 4 consists of a series of four controlled above-ground explosions designed to provide new data for overpressure propagation. Infrasound data were collected by LLNL iPhones and other sensors. Origin times, locations HOB, and yields are not being released at this time and are therefore not included in this report. This preliminary report will be updated as access to additional data changes, or instrument responses are determined.
Viral vectors for gene modification of plants as chem/bio sensors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manginell, Monica; Harper, Jason C.; Arango, Dulce C.
2006-11-01
Chemical or biological sensors that are specific, sensitive, and robust allowing intelligence gathering for verification of nuclear non-proliferation treaty compliance and detouring production of weapons of mass destruction are sorely needed. Although much progress has been made in the area of biosensors, improvements in sensor lifetime, robustness, and device packaging are required before these devices become widely used. Current chemical and biological detection and identification techniques require less-than-covert sample collection followed by transport to a laboratory for analysis. In addition to being expensive and time consuming, results can often be inconclusive due to compromised sample integrity during collection and transport.more » We report here a demonstration of a plant based sensor technology which utilizes mature and seedling plants as chemical sensors. One can envision genetically modifying native plants at a site of interest that can report the presence of specific toxins or chemicals. In this one year project we used a developed inducible expression system to show the feasibility of plant sensors. The vector was designed as a safe, non-infectious vector which could be used to invade, replicate, and introduce foreign genes into mature host plants that then allow the plant to sense chem/bio agents. The genes introduced through the vector included a reporter gene that encodes for green fluorescent protein (GFP) and a gene that encodes for a mammalian receptor that recognizes a chemical agent. Specifically, GFP was induced by the presence of 17-{beta}-Estradiol (estrogen). Detection of fluorescence indicated the presence of the target chemical agent. Since the sensor is a plant, costly device packaging development or manufacturing of the sensor were not required. Additionally, the biological recognition and reporting elements are maintained in a living, natural environment and therefore do not suffer from lifetime disadvantages typical of most biosensing platforms. Detection of the chem/bio agent reporter (GFP) can be detected only at a specific wavelength.« less
Fiber-pigtailed silicon photonic sensors for methane leak detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teng, Chu; Xiong, Chi; Zhang, Eric
We present comprehensive characterization of silicon photonic sensors for methane leak detection. Sensitivity of 40 ppmv after 1 second integration is reported. Fourier domain characterization of on-chip etalon drifts is used for further sensor improvement.
Cooperative implementation of a high temperature acoustic sensor
NASA Technical Reports Server (NTRS)
Baldini, S. E.; Nowakowski, Edward; Smith, Herbert G.; Friebele, E. J.; Putnam, Martin A.; Rogowski, Robert; Melvin, Leland D.; Claus, Richard O.; Tran, Tuan; Holben, Milford S., Jr.
1991-01-01
The current status and results of a cooperative program aimed at the implementation of a high-temperature acoustic/strain sensor onto metallic structures are reported. The sensor systems that are to be implemented under this program will measure thermal expansion, maneuver loads, aircraft buffet, sonic fatigue, and acoustic emissions in environments that approach 1800 F. The discussion covers fiber development, fabrication of an extrinsic Fabry-Perot interferometer acoustic sensor, sensor mounting/integration, and results of an evaluation of the sensor capabilities.
Guan, Zhonghui; Baker, Keith; Sandberg, Warren S
2009-11-01
We report a small case series in which misaligned disposable pulse oximeter sensors gave falsely low saturation readings. In each instance, the sensor performed well during preinduction oxygen administration and the early part of the case, most notably by producing a plethysmographic trace rated as high quality by the oximeter software. The reported pulse oximeter oxygen saturation eventually decreased to concerning levels in each instance, but the anesthesiologists, relying on the reported high-quality signal, initially sought other causes for apparent hypoxia. They undertook maneuvers and diagnostic procedures later deemed unnecessary. When the malpositioned sensors were discovered and repositioned, the apparent hypoxia was quickly relieved in each case. We then undertook a survey of disposable oximeter sensors as patients entered the recovery room, and discovered malposition of more than 1 cm in approximately 20% of all sensors, without apparent consequence. We conclude that the technology is quite robust, but that the diagnosis of apparent hypoxia should include a quick check of oximeter position early on.
Guimarães, Dayan Adionel; Sakai, Lucas Jun; Alberti, Antonio Marcos; de Souza, Rausley Adriano Amaral
2016-01-01
In this paper, a simple and flexible method for increasing the lifetime of fixed or mobile wireless sensor networks is proposed. Based on past residual energy information reported by the sensor nodes, the sink node or another central node dynamically optimizes the communication activity levels of the sensor nodes to save energy without sacrificing the data throughput. The activity levels are defined to represent portions of time or time-frequency slots in a frame, during which the sensor nodes are scheduled to communicate with the sink node to report sensory measurements. Besides node mobility, it is considered that sensors’ batteries may be recharged via a wireless power transmission or equivalent energy harvesting scheme, bringing to the optimization problem an even more dynamic character. We report large increased lifetimes over the non-optimized network and comparable or even larger lifetime improvements with respect to an idealized greedy algorithm that uses both the real-time channel state and the residual energy information. PMID:27657075
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Quinn; Jerry Mauck; Richard Bockhorst
The nuclear industry has been slow to incorporate digital sensor technology into nuclear plant designs due to concerns with digital qualification issues. However, the benefits of digital sensor technology for nuclear plant instrumentation are substantial in terms of accuracy, reliability, availability, and maintainability. This report demonstrates these benefits in direct comparisons of digital and analog sensor applications. It also addresses the qualification issues that must be addressed in the application of digital sensor technology.
Few-Flakes Reduced Graphene Oxide Sensors for Organic Vapors with a High Signal-to-Noise Ratio
Hasan, Nowzesh; Zhang, Wenli
2017-01-01
This paper reports our findings on how to prepare a graphene oxide-based gas sensor for sensing fast pulses of volatile organic compounds with a better signal-to-noise ratio. We use rapid acetone pulses of varying concentrations to test the sensors. First, we compare the effect of graphene oxide deposition method (dielectrophoresis versus solvent evaporation) on the sensor’s response. We find that dielectrophoresis yields films with uniform coverage and better sensor response. Second, we examine the effect of chemical reduction. Contrary to prior reports, we find that graphene oxide reduction leads to a reduction in sensor response and current noise, thus keeping the signal-to-noise ratio the same. We found that if we sonicated the sensor in acetone, we created a sensor with a few flakes of reduced graphene oxide. Such sensors provided a higher signal-to-noise ratio that could be correlated to the vapor concentration of acetone with better repeatability. Modeling shows that the sensor’s response is due to one-site Langmuir adsorption or an overall single exponent process. Further, the desorption of acetone as deduced from the sensor recovery signal follows a single exponent process. Thus, we show a simple way to improve the signal-to-noise ratio in reduced graphene oxide sensors. PMID:29065488
Gas Replacements for GFP to Track Microbial Dynamics in Soils and Sediments
NASA Astrophysics Data System (ADS)
Cheng, Hsiao-Ying; Silberg, Jonathan; Masiello, Caroline
2016-04-01
Metagenomic analyses offer unprecedented views of soil microbial communities, and additionally provide a host of testable hypotheses about the biological mechanisms driving global biogeochemical fluxes. Outside the biogeosciences, hypotheses generated by metagenomics are often tested using biosensors, microbes programmed to respond in a detectable way to either changes in their metabolism or changes in the environment. A very large number of microbial behaviors can be monitored using biosensors, but these sensors typically report in ways that are undetectable in soils, e.g. by releasing green fluorescent protein (GFP). We are building a new class of biosensors that report by releasing easily-detected gases. We will provide an overview of the potential uses of gas-reporting biosensors in geobiology, and will report the current development these sensors. One goal in the development of these sensors is to make tractable the testing of gene expression hypotheses derived from metagenomics data. Examples of processes that could be tracked non-invasively with gas sensors include coordination of biofilm formation, nitrification, rhizobial infection of plant roots, and at least some forms of methanogenesis, all of which are managed by the easily-engineered acyl homoserine lactone cell-cell communication system. Another relatively simple process to track with gas sensors is horizontal gene transfer. We will report on the progress of these proof-of-concept examples.
Guerreiro, Gabriela V; Zaitouna, Anita J; Lai, Rebecca Y
2014-01-31
Here we report the characterization of an electrochemical mercury (Hg(2+)) sensor constructed with a methylene blue (MB)-modified and thymine-containing linear DNA probe. Similar to the linear probe electrochemical DNA sensor, the resultant sensor behaved as a "signal-off" sensor in alternating current voltammetry and cyclic voltammetry. However, depending on the applied frequency or pulse width, the sensor can behave as either a "signal-off" or "signal-on" sensor in square wave voltammetry (SWV) and differential pulse voltammetry (DPV). In SWV, the sensor showed "signal-on" behavior at low frequencies and "signal-off" behavior at high frequencies. In DPV, the sensor showed "signal-off" behavior at short pulse widths and "signal-on" behavior at long pulse widths. Independent of the sensor interrogation technique, the limit of detection was found to be 10nM, with a linear dynamic range between 10nM and 500nM. In addition, the sensor responded to Hg(2+) rather rapidly; majority of the signal change occurred in <20min. Overall, the sensor retains all the characteristics of this class of sensors; it is reagentless, reusable, sensitive, specific and selective. This study also highlights the feasibility of using a MB-modified probe for real-time sensing of Hg(2+), which has not been previously reported. More importantly, the observed "switching" behavior in SWV and DPV is potentially generalizable and should be applicable to most sensors in this class of dynamics-based electrochemical biosensors. Copyright © 2013 Elsevier B.V. All rights reserved.
A GENERIC PACKAGING TECHNIQUE USING FLUIDIC ISOLATION FOR LOW-DRIFT IMPLANTABLE PRESSURE SENSORS.
Kim, A; Powell, C R; Ziaie, B
2015-06-01
This paper reports on a generic packaging method for reducing drift in implantable pressure sensors. The described technique uses fluidic isolation by encasing the pressure sensor in a liquid-filled medical-grade polyurethane balloon; thus, isolating it from surrounding aqueous environment that is the major source of baseline drift. In-vitro tests using commercial micromachined piezoresistive pressure sensors show an average baseline drift of 0.006 cmH 2 O/day (0.13 mmHg/month) for over 100 days of saline soak test, as compared to 0.101 cmH 2 O/day (2.23 mmHg/month) for a non-fluidic-isolated one soaked for 18 days. To our knowledge, this is the lowest reported drift for an implantable pressure sensor.
2012-04-05
C la ss ifi ca tio n TY PE D ep th (M ) A zi m ut h (D eg re es ) D ip (D eg re es ) 1 2 3...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --12-9401 TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO...NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2 . REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4
Twitter web-service for soft agent reporting in persistent surveillance systems
NASA Astrophysics Data System (ADS)
Rababaah, Haroun; Shirkhodaie, Amir
2010-04-01
Persistent surveillance is an intricate process requiring monitoring, gathering, processing, tracking, and characterization of many spatiotemporal events occurring concurrently. Data associated with events can be readily attained by networking of hard (physical) sensors. Sensors may have homogeneous or heterogeneous (hybrid) sensing modalities with different communication bandwidth requirements. Complimentary to hard sensors are human observers or "soft sensors" that can report occurrences of evolving events via different communication devices (e.g., texting, cell phones, emails, instant messaging, etc.) to the command control center. However, networking of human observers in ad-hoc way is rather a difficult task. In this paper, we present a Twitter web-service for soft agent reporting in persistent surveillance systems (called Web-STARS). The objective of this web-service is to aggregate multi-source human observations in hybrid sensor networks rapidly. With availability of Twitter social network, such a human networking concept can not only be realized for large scale persistent surveillance systems (PSS), but also, it can be employed with proper interfaces to expedite rapid events reporting by human observers. The proposed technique is particularly suitable for large-scale persistent surveillance systems with distributed soft and hard sensor networks. The efficiency and effectiveness of the proposed technique is measured experimentally by conducting several simulated persistent surveillance scenarios. It is demonstrated that by fusion of information from hard and soft agents improves understanding of common operating picture and enhances situational awareness.
Chow, James C; Breslauer, Leigh
2017-07-01
Albeit multifactorial, patient satisfaction is predominantly driven by postoperative pain and function. Unfortunately, approximately 20% of total knee arthroplasty (TKA) recipients are dissatisfied with the outcome of their surgery. Objective balancing of the soft tissue envelope may contribute to significant decrease in pain and increase in function when compared with traditional subjective methods. In an effort to confirm this, a cohort of manual TKA patient outcomes was compared with sensor-assisted TKA outcomes. One hundred fourteen patients (57 manual, 57 sensor assisted) received primary TKA. Both cohorts were matched for confounding variables. The dependent variables in this study were 6-month patient-reported outcome measures, including Knee Society Score and Oxford Knee Score. The range of motion and incidence of arthrofibrosis were also captured for both cohorts. The rate of improvement of all patient-reported outcome scores and subscores and range of motion was significantly higher in the sensor-assisted cohort. The rate of arthrofibrosis was lower in the sensor-assisted cohort but not statistically significant. The authors rejected the null hypothesis and concluded that the rate of improvement in objective, patient-reported outcome measures was higher in the sensor-assisted cohort than the manual cohort from preoperatively to 6 months postoperatively. [Orthopedics. 2017; 40(4):e648-e651.]. Copyright 2017, SLACK Incorporated.
Elman, Noel M; Ben-Yoav, Hadar; Sternheim, Marek; Rosen, Rachel; Krylov, Slava; Shacham-Diamand, Yosi
2008-06-15
A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-d-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection.
Environmental Technology Verification Report for Instrumentation Northwest, Inc., Aquistar® TempHion Smart Sensor and Datalogger Nitrate-specific Ion-selective Electrode for Groundwater Remediation Monitoring
Stylus type MEMS texture sensor covered with corrugated diaphragm
NASA Astrophysics Data System (ADS)
Tsukamoto, Takashiro; Asao, Hideaki; Tanaka, Shuji
2017-09-01
In this paper, a stylus type MEMS texture sensor covered with a corrugated palylene diaphragm, which prevent debris from jamming into the sensor without significant degradation of sensitivity and bandwidth, was reported. A new fabrication process using a lost-foil method to make the corrugated diaphragm on a 3-axis piezoresistive force sensor at wafer level has been developed. The texture sensor could detect the surface microstructure as small as about 10 \
A 128 x 128 CMOS Active Pixel Image Sensor for Highly Integrated Imaging Systems
NASA Technical Reports Server (NTRS)
Mendis, Sunetra K.; Kemeny, Sabrina E.; Fossum, Eric R.
1993-01-01
A new CMOS-based image sensor that is intrinsically compatible with on-chip CMOS circuitry is reported. The new CMOS active pixel image sensor achieves low noise, high sensitivity, X-Y addressability, and has simple timing requirements. The image sensor was fabricated using a 2 micrometer p-well CMOS process, and consists of a 128 x 128 array of 40 micrometer x 40 micrometer pixels. The CMOS image sensor technology enables highly integrated smart image sensors, and makes the design, incorporation and fabrication of such sensors widely accessible to the integrated circuit community.
Off-road axle detection sensor (ORADS) : final report, April 2001.
DOT National Transportation Integrated Search
2001-04-01
Spectra Research has developed a non-intrusive lane monitoring sensor which can be used to measure and classify vehicular traffic over multiple lane roadways. This sensor employs dual beam laser radar (LADAR) that accurately measures location and pas...
Sensors Workshop summary report
NASA Technical Reports Server (NTRS)
1977-01-01
A review of the efforts of three workshops is presented. The presentation describes those technological developments that would contribute most to sensor subsystem optimization and improvement of NASA's data acquisition capabilities, and summarizes the recommendations of the sensor technology panels from the most recent workshops.
This report is the result of low cost air quality sensor performance trials conducted in the NERL’s on-site laboratories located in the Research Triangle Park, NC during 2012-2013. Such trials were viewed as highly valuable for all parties following the conclusion of the U.S. E...
NASA Technical Reports Server (NTRS)
Everett, L.
1992-01-01
This report documents the performance characteristics of a Targeting Reflective Alignment Concept (TRAC) sensor. The performance will be documented for both short and long ranges. For long ranges, the sensor is used without the flat mirror attached to the target. To better understand the capabilities of the TRAC based sensors, an engineering model is required. The model can be used to better design the system for a particular application. This is necessary because there are many interrelated design variables in application. These include lense parameters, camera, and target configuration. The report presents first an analytical development of the performance, and second an experimental verification of the equations. In the analytical presentation it is assumed that the best vision resolution is a single pixel element. The experimental results suggest however that the resolution is better than 1 pixel. Hence the analytical results should be considered worst case conditions. The report also discusses advantages and limitations of the TRAC sensor in light of the performance estimates. Finally the report discusses potential improvements.
Sheykhi, Sara; Mosca, Lorenzo; Anzenbacher, Pavel
2017-05-04
Increasing security needs require compact and portable detection tools for the rapid and reliable identification of explosives used in improvised explosive devices (IEDs). We report of an easy-to-use optical sensor for both vapour-phase and solution-phase identification of explosive mixtures that uses a cross-reactive fluorimetric sensor array comprising chemically responsive fluorimetric indicators composed of aromatic aldehydes and polyethyleneimine. Ammonium nitrate-nitromethane (ANNM) was analyzed by paper microzone arrays and nanofiber sensor mats. Progress toward wearable sensors based on electrospun nanofiber mats is outlined.
Sensors for process control Focus Team report
NASA Astrophysics Data System (ADS)
At the Semiconductor Technology Workshop, held in November 1992, the Semiconductor Industry Association (SIA) convened 179 semiconductor technology experts to assess the 15-year outlook for the semiconductor manufacturing industry. The output of the Workshop, a document entitled 'Semiconductor Technology: Workshop Working Group Reports,' contained an overall roadmap for the technology characteristics envisioned in integrated circuits (IC's) for the period 1992-2007. In addition, the document contained individual roadmaps for numerous key areas in IC manufacturing, such as film deposition, thermal processing, manufacturing systems, exposure technology, etc. The SIA Report did not contain a separate roadmap for contamination free manufacturing (CFM). A key component of CFM for the next 15 years is the use of sensors for (1) defect reduction, (2) improved product quality, (3) improved yield, (4) improved tool utilization through contamination reduction, and (5) real time process control in semiconductor fabrication. The objective of this Focus Team is to generate a Sensors for Process Control Roadmap. Implicit in this objective is the identification of gaps in current sensor technology so that research and development activity in the sensor industry can be stimulated to develop sensor systems capable of meeting the projected roadmap needs. Sensor performance features of interest include detection limit, specificity, sensitivity, ease of installation and maintenance, range, response time, accuracy, precision, ease and frequency of calibration, degree of automation, and adaptability to in-line process control applications.
Multi-Modalities Sensor Science
2015-02-28
enhanced multi-mode sensor science. bio -sensing, cross-discipling, multi-physics, nano-technology sailing He +46-8790 8465 1 Final Report for SOARD Project...spectroscopy, nano-technology, biophotonics and multi-physics modeling to produce adaptable bio -nanostructure enhanced multi-mode sensor science. 1...adaptable bio -nanostructure enhanced multi-mode sensor science. The accomplishments includes 1) A General Method for Designing a Radome to Enhance
Advanced scanners and imaging systems for earth observations. [conferences
NASA Technical Reports Server (NTRS)
1973-01-01
Assessments of present and future sensors and sensor related technology are reported along with a description of user needs and applications. Five areas are outlined: (1) electromechanical scanners, (2) self-scanned solid state sensors, (3) electron beam imagers, (4) sensor related technology, and (5) user applications. Recommendations, charts, system designs, technical approaches, and bibliographies are included for each area.
Two-photon fluorescent sensor for K+ imaging in live cells (Conference Presentation)
NASA Astrophysics Data System (ADS)
Sui, Binglin; Yue, Xiling; Kim, Bosung; Belfield, Kevin D.
2016-03-01
It is difficult to overstate the physiological importance of potassium for life as its indispensable roles in a variety of biological processes are widely known. As a result, efficient methods for determining physiological levels of potassium are of paramount importance. Despite this, relatively few K+ fluorescence sensors have been reported, with only one being commercially available. A new two-photon excited fluorescent K+ sensor is reported. The sensor is comprised of three moieties, a highly selective K+ chelator as the K+ recognition unit, a boron-dipyrromethene (BODIPY) derivative modified with phenylethynyl groups as the fluorophore, and two polyethylene glycol chains to afford water solubility. The sensor displays very high selectivity (<52-fold) in detecting K+ over other physiological metal cations. Upon binding K+, the sensor switches from non-fluorescent to highly fluorescent, emitting red to near-IR (NIR) fluorescence. The sensor exhibited a good two-photon absorption cross section, 500 GM at 940 nm. Moreover, it is not sensitive to pH in the physiological pH range. Time-dependent cell imaging studies via both one- and two-photon fluorescence microscopy demonstrate that the sensor is suitable for dynamic K+ sensing in living cells.
RSA/Legacy Wind Sensor Comparison. Part 1; Western Range
NASA Technical Reports Server (NTRS)
Short, David A.; Wheeler, Mark M.
2006-01-01
This report describes a comparison of data from ultrasonic and cup-and-vane anemometers on 5 wind towers at Vandenberg AFB. The ultrasonic sensors are scheduled to replace the Legacy cup-and-vane sensors under the Range Standardization and Automation (RSA) program. Because previous studies have noted differences between peak wind speeds reported by mechanical and ultrasonic wind sensors, the latter having no moving parts, the 30th and 45th Weather Squadrons wanted to understand possible differences between the two sensor types. The period-of-record was 13-30 May 2005. A total of 153,961 readings of I-minute average and peak wind speed/direction from each sensor type were used. Statistics of differences in speed and direction were used to identify 18 out of 34 RSA sensors having the most consistent performance, with respect to the Legacy sensors. Data from these 18 were used to form a composite comparison. A small positive bias in the composite RSA average wind speed increased from +0.5 kts at 15 kts, to +1 kt at 25 kts. A slightly larger positive bias in the RSA peak wind speed increased from +1 kt at 15 kts, to +2 kts at 30 kts.
COMSOL-Based Modeling and Simulation of SnO2/rGO Gas Sensor for Detection of NO2.
Yaghouti Niyat, Farshad; Shahrokh Abadi, M H
2018-02-01
Despite SIESTA and COMSOL being increasingly used for the simulation of the sensing mechanism in the gas sensors, there are no modeling and simulation reports in literature for detection of NO 2 based rGO/SnO 2 sensors. In the present study, we model, simulate, and characterize an NO 2 based rGO/SnO 2 gas sensor using COMSOL by solving the Poisson's equations under associated boundary conditions of mass, heat and electrical transitions. To perform the simulation, we use an exposure model for presenting the required NO 2 , a heat transfer model to obtain a reaction temperature, and an electrical model to characterize the sensor's response in the presence of the gas. We characterize the sensor's response in the presence of different concentrations of NO 2 at different working temperatures and compare the results with the experimental data, reported by Zhang et al. The results from the simulated sensor show a good agreement with the real sensor with some inconsistencies due to differences between the practical conditions in the real chamber and applied conditions to the analytical equations. The results also show that the method can be used to define and predict the behavior of the rGO-based gas sensors before undergoing the fabrication process.
2016-07-18
Research Laboratory Space Vehicles Directorate 3550 Aberdeen Avenue SE Kirtland AFB, NM 87117-5776 8. PERFORMING ORGANIZATION REPORT NUMBER AFRL -RV...Satellite Program Space Weather Sensors (1 Dec 2000 – 30 Nov 2014), AFRL -RV-PS-TR-2016-0053, Air Force Research Laboratory, Kirtland AFB, NM, Jan 2015. [2...Archive Listing (1982-2013) and File Formats Descriptions, AFRL -RV-PR-TR-2014-0174, Air Force Research Laboratory, Kirtland AFB, NM, Aug 2014. [3
NASA Technical Reports Server (NTRS)
Abbott, David; Batten, Adam; Carpenter, David; Dunlop, John; Edwards, Graeme; Farmer, Tony; Gaffney, Bruce; Hedley, Mark; Hoschke, Nigel; Isaacs, Peter;
2008-01-01
This report describes the first phase of the implementation of the Concept Demonstrator. The Concept Demonstrator system is a powerful and flexible experimental test-bed platform for developing sensors, communications systems, and multi-agent based algorithms for an intelligent vehicle health monitoring system for deployment in aerospace vehicles. The Concept Demonstrator contains sensors and processing hardware distributed throughout the structure, and uses multi-agent algorithms to characterize impacts and determine an appropriate response to these impacts.
Design and Simulation Test of an Open D-Dot Voltage Sensor
Bai, Yunjie; Wang, Jingang; Wei, Gang; Yang, Yongming
2015-01-01
Nowadays, sensor development focuses on miniaturization and non-contact measurement. According to the D-dot principle, a D-dot voltage sensor with a new structure was designed based on the differential D-dot sensor with a symmetrical structure, called an asymmetric open D-dot voltage sensor. It is easier to install. The electric field distribution of the sensor was analyzed through Ansoft Maxwell and an open D-dot voltage sensor was designed. This open D-voltage sensor is characteristic of accessible insulating strength and small electric field distortion. The steady and transient performance test under 10 kV-voltage reported satisfying performances of the designed open D-dot voltage sensor. It conforms to requirements for a smart grid measuring sensor in intelligence, miniaturization and facilitation. PMID:26393590
A self-assembled supramolecular optical sensor for NiII, CdII, and CrIII.
Resendiz, Marino J E; Noveron, Juan C; Disteldorf, Hendrick; Fischer, Sonja; Stang, Peter J
2004-03-04
A new chromogenic supramolecular sensor for transition metals is reported. It is based on a newly designed phenanthroline-containing molecule that self-assembles via an organometallic "clip" into a supramolecular optical sensor for metals. [reaction: see text
System Aware Cybersecurity: A Multi-Sentinel Scheme to Protect a Weapons Research Lab
2015-12-07
In the simplified deployment scenario, some sensors report their output over a wireless link and other sensors are connected via CAT 5 (Ethernet...cable to reduce the chance of a wireless ‘jamming’ event impacting ALL sensors . In addition to this first sensor suite ( Sensor Suite “A”), the team...generating wind turbines , and video reconnaissance systems on unmanned aerial vehicles (UAVs). The most basic decision problem in designing a systems
Optical fiber sensors for materials and structures characterization
NASA Technical Reports Server (NTRS)
Lindner, D. K.; Claus, R. O.
1991-01-01
The final technical report on Optical Fiber Sensors for Materials and Structures Characterization, covering the period August 1990 through August 1991 is presented. Research programs in the following technical areas are described; sapphire optical fiber sensors; vibration analysis using two-mode elliptical core fibers and sensors; extrinsic Fabry-Perot interferometer development; and coatings for fluorescent-based sensor. Research progress in each of these areas was substantial, as evidenced by the technical publications which are included as appendices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishra, Prabhash; Grachyova, D. V.; Moskalenko, A. S.
2016-04-13
Dispersion of single-walled carbon nanotubes (SWCNTs) is an established fact, however, its effect on toxic gas sensing for the development of solid state resistive sensor was not well reported. In this report, the dispersion quality of SWCNTs has been investigated and improved, and this well-dispersed SWCNTs network was used for sensor fabrication to monitor nitrogen dioxide gas. Ultraviolet (UV)-visible spectroscopic studies shows the strength of SWNTs dispersion and scanning electron microscopy (SEM) imaging provides the morphological properties of the sensor device. In this gas sensor device, two sets of resistive type sensors were fabricated that consisting of a pair ofmore » interdigitated electrodes (IDEs) using dielectrophoresis technique with different SWCNTs network density. With low-density SWCNTs networks, this fabricated sensor exhibits a high response for nitrogen dioxide sensing. The sensing of nitrogen dioxide is mainly due to charge transfer from absorbed molecules to sidewalls of nanotube and tube-tube screening acting a major role for the transport properties of charge carriers.« less
OPTICAL FIBER SENSOR TECHNOLOGIES FOR EFFICIENT AND ECONOMICAL OIL RECOVERY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kristie Cooper; Gary Pickrell; Anbo Wang
2003-04-01
This report summarizes technical progress over the fourth year of the ''Optical Fiber Sensor Technologies for Efficient and Economical Oil Recovery'' program, funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. During the reporting period, research efforts under the program were focused on the development and evaluation of the fiber optic flow sensor system, and field testing in Tulsa, OK and the second field test of the pressure and temperature sensors in Coalinga, CA. The feasibilitymore » of a self-compensating fiber optic flow sensor based on a cantilever beam and interferometer for real-time flow rate measurements in the fluid filled pipes of oil field was clearly demonstrated. In addition, field testing of the pressure and temperature sensors deployed downhole continued. These accomplishments are summarized here: (1) Theoretical analysis and simulations were performed to ensure performance of the design. (2) The sensor fabrication and packaging techniques were investigated and improved. (3) Prototype flow sensors were fabricated based on the fabrication experience of hundreds of test sensors. (4) A lab-scale flow testing system was constructed and used for sensor evaluation. (5) Field-testing was performed in both the indoor and outdoor flow testing facility at the University of Tulsa, OK. (6) Testing of a multimode white light pressure and temperature sensor system continued at the oil site of Chevron/Texaco Company (Coalinga CA).« less
Aptamer sensor for cocaine using minor groove binder based energy transfer.
Zhou, Jinwen; Ellis, Amanda V; Kobus, Hilton; Voelcker, Nicolas H
2012-03-16
We report on an optical aptamer sensor for cocaine detection. The cocaine sensitive fluorescein isothiocyanate (FITC)-labeled aptamer underwent a conformational change from a partial single-stranded DNA with a short hairpin to a double-stranded T-junction in the presence of the target. The DNA minor groove binder Hoechst 33342 selectively bound to the double-stranded T-junction, bringing the dye within the Förster radius of FITC, and therefore initiating minor groove binder based energy transfer (MBET), and reporting on the presence of cocaine. The sensor showed a detection limit of 0.2 μM. The sensor was also implemented on a carboxy-functionalized polydimethylsiloxane (PDMS) surface by covalently immobilizing DNA aptamers. The ability of surface-bound cocaine detection is crucial for the development of microfluidic sensors. Copyright © 2012 Elsevier B.V. All rights reserved.
MacRae, Braid A.; Annaheim, Simon; Spengler, Christina M.; Rossi, René M.
2018-01-01
Background: Skin temperature (Tskin) is commonly measured using Tskin sensors affixed directly to the skin surface, although the influence of setup variables on the measured outcome requires clarification. Objectives: The two distinct objectives of this systematic review were (1) to examine measurements from contact Tskin sensors considering equilibrium temperature and temperature disturbance, sensor attachments, pressure, environmental temperature, and sensor type, and (2) to characterise the contact Tskin sensors used, conditions of use, and subsequent reporting in studies investigating sports, exercise, and other physical activity. Data sources and study selection: For the measurement comparison objective, Ovid Medline and Scopus were used (1960 to July 2016) and studies comparing contact Tskin sensor measurements in vivo or using appropriate physical models were included. For the survey of use, Ovid Medline was used (2011 to July 2016) and studies using contact temperature sensors for the measurement of human Tskin in vivo during sport, exercise, and other physical activity were included. Study appraisal and synthesis methods: For measurement comparisons, assessments of risk of bias were made according to an adapted version of the Cochrane Collaboration's risk of bias tool. Comparisons of temperature measurements were expressed, where possible, as mean difference and 95% limits of agreement (LoA). Meta-analyses were not performed due to the lack of a common reference condition. For the survey of use, extracted information was summarised in text and tabular form. Results: For measurement comparisons, 21 studies were included. Results from these studies indicated minor (<0.5°C) to practically meaningful (>0.5°C) measurement bias within the subgroups of attachment type, applied pressure, environmental conditions, and sensor type. The 95% LoA were often within 1.0°C for in vivo studies and 0.5°C for physical models. For the survey of use, 172 studies were included. Details about Tskin sensor setup were often poorly reported and, from those reporting setup information, it was evident that setups widely varied in terms of type of sensors, attachments, and locations used. Conclusions: Setup variables and conditions of use can influence the measured temperature from contact Tskin sensors and thus key setup variables need to be appropriately considered and consistently reported. PMID:29441024
MacRae, Braid A; Annaheim, Simon; Spengler, Christina M; Rossi, René M
2018-01-01
Background: Skin temperature ( T skin ) is commonly measured using T skin sensors affixed directly to the skin surface, although the influence of setup variables on the measured outcome requires clarification. Objectives: The two distinct objectives of this systematic review were (1) to examine measurements from contact T skin sensors considering equilibrium temperature and temperature disturbance, sensor attachments, pressure, environmental temperature, and sensor type, and (2) to characterise the contact T skin sensors used, conditions of use, and subsequent reporting in studies investigating sports, exercise, and other physical activity. Data sources and study selection: For the measurement comparison objective, Ovid Medline and Scopus were used (1960 to July 2016) and studies comparing contact T skin sensor measurements in vivo or using appropriate physical models were included. For the survey of use, Ovid Medline was used (2011 to July 2016) and studies using contact temperature sensors for the measurement of human T skin in vivo during sport, exercise, and other physical activity were included. Study appraisal and synthesis methods: For measurement comparisons, assessments of risk of bias were made according to an adapted version of the Cochrane Collaboration's risk of bias tool. Comparisons of temperature measurements were expressed, where possible, as mean difference and 95% limits of agreement (LoA). Meta-analyses were not performed due to the lack of a common reference condition. For the survey of use, extracted information was summarised in text and tabular form. Results: For measurement comparisons, 21 studies were included. Results from these studies indicated minor (<0.5°C) to practically meaningful (>0.5°C) measurement bias within the subgroups of attachment type, applied pressure, environmental conditions, and sensor type. The 95% LoA were often within 1.0°C for in vivo studies and 0.5°C for physical models. For the survey of use, 172 studies were included. Details about T skin sensor setup were often poorly reported and, from those reporting setup information, it was evident that setups widely varied in terms of type of sensors, attachments, and locations used. Conclusions: Setup variables and conditions of use can influence the measured temperature from contact T skin sensors and thus key setup variables need to be appropriately considered and consistently reported.
A Miniaturized QEPAS Trace Gas Sensor with a 3D-Printed Acoustic Detection Module.
Yang, Xiaotao; Xiao, Youhong; Ma, Yufei; He, Ying; Tittel, Frank K
2017-07-31
A 3D printing technique was introduced to a quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor and is reported for the first time. The acoustic detection module (ADM) was designed and fabricated using the 3D printing technique and the ADM volume was compressed significantly. Furthermore, a small grin lens was used for laser focusing and facilitated the beam adjustment in the 3D-printed ADM. A quartz tuning fork (QTF) with a low resonance frequency of 30.72 kHz was used as the acoustic wave transducer and acetylene (C₂H₂) was chosen as the analyte. The reported miniaturized QEPAS trace gas sensor is useful in actual sensor applications.
Namour, Philippe; Lepot, Mathieu; Jaffrezic-Renault, Nicole
2010-01-01
This review discusses from a critical perspective the development of new sensors for the measurement of priority pollutants targeted in the E.U. Water Framework Directive. Significant advances are reported in the paper and their advantages and limitations are also discussed. Future perspectives in this area are also pointed out in the conclusions. This review covers publications appeared since December 2006 (the publication date of the Swift report). Among priority substances, sensors for monitoring the four WFD metals represent 81% of published papers. None of analyzed publications present a micro-sensor totally validated in laboratory, ready for tests under real conditions in the field. The researches are mainly focused on the sensing part of the micro-sensors. Nevertheless, the main factor limiting micro-sensor applications in the environment is the ruggedness of the receptor towards environmental conditions. This point constitutes the first technological obstacle to be overcome for any long-term field tests. PMID:22163635
Sensing Properties of a Novel Temperature Sensor Based on Field Assisted Thermal Emission.
Pan, Zhigang; Zhang, Yong; Cheng, Zhenzhen; Tong, Jiaming; Chen, Qiyu; Zhang, Jianpeng; Zhang, Jiaxiang; Li, Xin; Li, Yunjia
2017-02-27
The existing temperature sensors using carbon nanotubes (CNTs) are limited by low sensitivity, complicated processes, or dependence on microscopy to observe the experimental results. Here we report the fabrication and successful testing of an ionization temperature sensor featuring non-self-sustaining discharge. The sharp tips of nanotubes generate high electric fields at relatively low voltages, lowering the work function of electrons emitted by CNTs, and thereby enabling the safe operation of such sensors. Due to the temperature effect on the electron emission of CNTs, the collecting current exhibited an exponential increase with temperature rising from 20 °C to 100 °C. Additionally, a higher temperature coefficient of 0.04 K -1 was obtained at 24 V voltage applied on the extracting electrode, higher than the values of other reported CNT-based temperature sensors. The triple-electrode ionization temperature sensor is easy to fabricate and converts the temperature change directly into an electrical signal. It shows a high temperature coefficient and good application potential.
Sensing Properties of a Novel Temperature Sensor Based on Field Assisted Thermal Emission
Pan, Zhigang; Zhang, Yong; Cheng, Zhenzhen; Tong, Jiaming; Chen, Qiyu; Zhang, Jianpeng; Zhang, Jiaxiang; Li, Xin; Li, Yunjia
2017-01-01
The existing temperature sensors using carbon nanotubes (CNTs) are limited by low sensitivity, complicated processes, or dependence on microscopy to observe the experimental results. Here we report the fabrication and successful testing of an ionization temperature sensor featuring non-self-sustaining discharge. The sharp tips of nanotubes generate high electric fields at relatively low voltages, lowering the work function of electrons emitted by CNTs, and thereby enabling the safe operation of such sensors. Due to the temperature effect on the electron emission of CNTs, the collecting current exhibited an exponential increase with temperature rising from 20 °C to 100 °C. Additionally, a higher temperature coefficient of 0.04 K−1 was obtained at 24 V voltage applied on the extracting electrode, higher than the values of other reported CNT-based temperature sensors. The triple-electrode ionization temperature sensor is easy to fabricate and converts the temperature change directly into an electrical signal. It shows a high temperature coefficient and good application potential. PMID:28264427
Engineering Genetically Encoded FRET Sensors
Lindenburg, Laurens; Merkx, Maarten
2014-01-01
Förster Resonance Energy Transfer (FRET) between two fluorescent proteins can be exploited to create fully genetically encoded and thus subcellularly targetable sensors. FRET sensors report changes in energy transfer between a donor and an acceptor fluorescent protein that occur when an attached sensor domain undergoes a change in conformation in response to ligand binding. The design of sensitive FRET sensors remains challenging as there are few generally applicable design rules and each sensor must be optimized anew. In this review we discuss various strategies that address this shortcoming, including rational design approaches that exploit self-associating fluorescent domains and the directed evolution of FRET sensors using high-throughput screening. PMID:24991940
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, Dean James; Brusseau, Charles A.
2012-01-01
This document is a final report for the polyvinyl toluene (PVT) neutron-gamma (PVT-NG) project, which was sponsored by the Domestic Nuclear Detection Office (DNDO). The PVT-NG sensor uses PVT detectors for both gamma and neutron detection. The sensor exhibits excellent spectral resolution and gain stabilization, which are features that are beneficial for detection of both gamma-ray and neutron sources. In fact, the ability to perform isotope identification based on spectra that were measured by the PVT-NG sensor was demonstrated. As described in a previous report, the neutron sensitivity of the first version of the prototype was about 25% less thanmore » the DNDO requirement of 2.5 cps/ng for bare Cf-252. This document describes design modifications that were expected to improve the neutron sensitivity by about 50% relative to the PVT-NG prototype. However, the project was terminated before execution of the design modifications after portal vendors demonstrated other technologies that enable neutron detection without the use of He-3. Nevertheless, the PVT-NG sensor development demonstrated several performance goals that may be useful in future portal designs.« less
Time-Resolved Measurements in Optoelectronic Microbioanalysis
NASA Technical Reports Server (NTRS)
Bearman, Gregory; Kossakovski, Dmitri
2003-01-01
A report presents discussion of time-resolved measurements in optoelectronic microbioanalysis. Proposed microbioanalytical laboratory-on-a-chip devices for detection of microbes and toxic chemicals would include optoelectronic sensors and associated electronic circuits that would look for fluorescence or phosphorescence signatures of multiple hazardous biomolecules in order to detect which ones were present in a given situation. The emphasis in the instant report is on gating an active-pixel sensor in the time domain, instead of filtering light in the wavelength domain, to prevent the sensor from responding to a laser pulse used to excite fluorescence or phosphorescence while enabling the sensor to respond to the decaying fluorescence or phosphorescence signal that follows the laser pulse. The active-pixel sensor would be turned on after the laser pulse and would be used to either integrate the fluorescence or phosphorescence signal over several lifetimes and many excitation pulses or else take time-resolved measurements of the fluorescence or phosphorescence. The report also discusses issues of multiplexing and of using time-resolved measurements of fluorophores with known different fluorescence lifetimes to distinguish among them.
NASA Astrophysics Data System (ADS)
Gruber, Thomas; Grim, Larry; Fauth, Ryan; Tercha, Brian; Powell, Chris; Steinhardt, Kristin
2011-05-01
Large networks of disparate chemical/biological (C/B) sensors, MET sensors, and intelligence, surveillance, and reconnaissance (ISR) sensors reporting to various command/display locations can lead to conflicting threat information, questions of alarm confidence, and a confused situational awareness. Sensor netting algorithms (SNA) are being developed to resolve these conflicts and to report high confidence consensus threat map data products on a common operating picture (COP) display. A data fusion algorithm design was completed in a Phase I SBIR effort and development continues in the Phase II SBIR effort. The initial implementation and testing of the algorithm has produced some performance results. The algorithm accepts point and/or standoff sensor data, and event detection data (e.g., the location of an explosion) from various ISR sensors (e.g., acoustic, infrared cameras, etc.). These input data are preprocessed to assign estimated uncertainty to each incoming piece of data. The data are then sent to a weighted tomography process to obtain a consensus threat map, including estimated threat concentration level uncertainty. The threat map is then tested for consistency and the overall confidence for the map result is estimated. The map and confidence results are displayed on a COP. The benefits of a modular implementation of the algorithm and comparisons of fused / un-fused data results will be presented. The metrics for judging the sensor-netting algorithm performance are warning time, threat map accuracy (as compared to ground truth), false alarm rate, and false alarm rate v. reported threat confidence level.
Sentient Structures: Optimising Sensor Layouts for Direct Measurement of Discrete Variables
2008-11-01
1 Sentient Structures Optimising Sensor Layouts for Direct Measurement of Discrete Variables Report to US Air Force...TITLE AND SUBTITLE Sentient Structures 5a. CONTRACT NUMBER FA48690714045 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Donald Price...optimal sensor placements is an important requirement for the development of sentient structures. An optimal sensor layout is attained when a limited
Telemetric Sensors for the Space Life Sciences
NASA Technical Reports Server (NTRS)
Hines, John W.; Somps, Chris J.; Madou, Marc; Jeutter, Dean C.; Singh, Avtar; Connolly, John P. (Technical Monitor)
1996-01-01
Telemetric sensors for monitoring physiological changes in animal models in space are being developed by NASA's Sensors 2000! program. The sensors measure a variety of physiological measurands, including temperature, biopotentials, pressure, flow, acceleration, and chemical levels, and transmit these signals from the animals to a remote receiver via a wireless link. Thus physiologic information can be obtained continuously and automatically without animal handling, tethers, or percutaneous leads. We report here on NASA's development and testing of advanced wireless sensor systems for space life sciences research.
Improved blood glucose estimation through multi-sensor fusion.
Xiong, Feiyu; Hipszer, Brian R; Joseph, Jeffrey; Kam, Moshe
2011-01-01
Continuous glucose monitoring systems are an integral component of diabetes management. Efforts to improve the accuracy and robustness of these systems are at the forefront of diabetes research. Towards this goal, a multi-sensor approach was evaluated in hospitalized patients. In this paper, we report on a multi-sensor fusion algorithm to combine glucose sensor measurements in a retrospective fashion. The results demonstrate the algorithm's ability to improve the accuracy and robustness of the blood glucose estimation with current glucose sensor technology.
Characterizing Semiconductor Alloys for Infrared Sensors
NASA Technical Reports Server (NTRS)
Lehoczky, B. S. L.; Szofran, F. R.; Martin, B. G.
1986-01-01
Report presents results of continuing program aimed at characterizing mercury/cadmium/tellurium alloys and eventually developing improved methods of preparing alloys for use as infrared sensors. Work covered by report includes series of differential thermal analysis (DTA) measurements of alloy compositions with x varied from 9 to 1 in 0.1 increments.
Time-optimum packet scheduling for many-to-one routing in wireless sensor networks
Song, W.-Z.; Yuan, F.; LaHuser, R.
2007-01-01
This paper studies the WSN application scenario with periodical traffic from all sensors to a sink. We present a time-optimum and energy-efficient packet scheduling algorithm and its distributed implementation. We first give a general many-to-one packet scheduling algorithm for wireless networks, and then prove that it is time-optimum and costs max(2N(u1) - 1, N(u 0) -1) time slots, assuming each node reports one unit of data in each round. Here N(u0) is the total number of sensors, while N(u 1) denotes the number of sensors in a sink's largest branch subtree. With a few adjustments, we then show that our algorithm also achieves time-optimum scheduling in heterogeneous scenarios, where each sensor reports a heterogeneous amount of data in each round. Then we give a distributed implementation to let each node calculate its duty-cycle locally and maximize efficiency globally. In this packet scheduling algorithm, each node goes to sleep whenever it is not transceiving, so that the energy waste of idle listening is also eliminated. Finally, simulations are conducted to evaluate network performance using the Qualnet simulator. Among other contributions, our study also identifies the maximum reporting frequency that a deployed sensor network can handle. ??2006 IEEE.
NASA Technical Reports Server (NTRS)
Shevade, A. V.; Ryan, M. A.; Homer, M. L.; Jewell, A. D.; Zhou, H.; Manatt, K.; Kisor, A. K.
2005-01-01
We report a Quantitative Structure-Activity Relationships (QSAR) study using Genetic Function Approximations (GFA) to describe the polymer-carbon composite sensor activities in the JPL Electronic Nose, when exposed to chemical vapors at parts-per-million concentration levels.
Wireless sensor network effectively controls center pivot irrigation of sorghum
USDA-ARS?s Scientific Manuscript database
Robust automatic irrigation scheduling has been demonstrated using wired sensors and sensor network systems with subsurface drip and moving irrigation systems. However, there are limited studies that report on crop yield and water use efficiency resulting from the use of wireless networks to automat...
Development of a Spoke Type Torque Sensor Using Painting Carbon Nanotube Strain Sensors.
Kim, Sung Yong; Park, Se Hoon; Choi, Baek Gyu; Kang, In Hyuk; Park, Sang Wook; Shin, Jeong Woo; Kim, Jin Ho; Baek, Woon Kyung; Lim, Kwon Taek; Kim, Young-Ju; Song, Jae-Bok; Kang, Inpil
2018-03-01
This study reports a hub-spoke type joint torque sensor involving strain gauges made of multiwalled carbon nanotubes (MWCNT). We developed the novel joint torque sensor for robots by means of MWCNT/epoxy strain sensors (0.8 wt%, gauge factor 2) to overcome the limits of conventional foil strain gauges. Solution mixing process was hired to fabricate a liquid strain sensor that can easily be installed on any complicated surfaces. We painted the MWCNT/epoxy mixing liquid on the hub-spoke type joint torque sensor to form the piezoresistive strain gauges. The painted sensor converted its strain into torque by mean of the installed hub-spoke structure after signal processing. We acquired sufficient torque voltage responses from the painted MWCNT/epoxy strain sensor.
Defect-Mediated Molecular Interaction and Charge Transfer in Graphene Mesh-Glucose Sensors.
Kwon, Sun Sang; Shin, Jae Hyeok; Choi, Jonghyun; Nam, SungWoo; Park, Won Il
2017-04-26
We report the role of defects in enzymatic graphene field-effect transistor sensors by introducing engineered defects in graphene channels. Compared with conventional graphene sensors (Gr sensors), graphene mesh sensors (GM sensors), with an array of circular holes, initially exhibited a higher irreversible response to glucose, involving strong chemisorption to edge defects. However, after immobilization of glucose oxidase, the irreversibility of the responses was substantially diminished, without any reduction in the sensitivity of the GM sensors (i.e., -0.53 mV/mM for the GM sensor vs -0.37 mV/mM for Gr sensor). Furthermore, multiple cycle operation led to rapid sensing and improved the reversibility of GM sensors. In addition, control tests with sensors containing a linker showed that sensitivity was increased in Gr sensors but decreased in GM sensors. Our findings indicate that edge defects can be used to replace linkers for immobilization of glucose oxidase and improve charge transfer across glucose oxidase-graphene interfaces.
Detection of Obstacles in Monocular Image Sequences
NASA Technical Reports Server (NTRS)
Kasturi, Rangachar; Camps, Octavia
1997-01-01
The ability to detect and locate runways/taxiways and obstacles in images captured using on-board sensors is an essential first step in the automation of low-altitude flight, landing, takeoff, and taxiing phase of aircraft navigation. Automation of these functions under different weather and lighting situations, can be facilitated by using sensors of different modalities. An aircraft-based Synthetic Vision System (SVS), with sensors of different modalities mounted on-board, complements the current ground-based systems in functions such as detection and prevention of potential runway collisions, airport surface navigation, and landing and takeoff in all weather conditions. In this report, we address the problem of detection of objects in monocular image sequences obtained from two types of sensors, a Passive Millimeter Wave (PMMW) sensor and a video camera mounted on-board a landing aircraft. Since the sensors differ in their spatial resolution, and the quality of the images obtained using these sensors is not the same, different approaches are used for detecting obstacles depending on the sensor type. These approaches are described separately in two parts of this report. The goal of the first part of the report is to develop a method for detecting runways/taxiways and objects on the runway in a sequence of images obtained from a moving PMMW sensor. Since the sensor resolution is low and the image quality is very poor, we propose a model-based approach for detecting runways/taxiways. We use the approximate runway model and the position information of the camera provided by the Global Positioning System (GPS) to define regions of interest in the image plane to search for the image features corresponding to the runway markers. Once the runway region is identified, we use histogram-based thresholding to detect obstacles on the runway and regions outside the runway. This algorithm is tested using image sequences simulated from a single real PMMW image.
Joint Sensor: Security Test and Evaluation Embedded in a Production Network Sensor Cloud
2010-12-01
read of this year’s Verizon 2010 Data Breach Investigations Report (Baker et al. 2010) may in a sense reiterate the assumptions and propagate the...in 2002. He currently serves as the program manager for the DREN. E-mail: rcampbell@hpcmo.hpc.mil References Baker, W., et al. 2010. 2010 data breach investiga...tions report. http://www.verizonbusiness.com/resources/ reports/rp_2010- data - breach -report_en_xg.pdf (ac- cessed October 13, 2010
Thermal Characterization of a Simulated Fission Engine via Distributed Fiber Bragg Gratings
NASA Astrophysics Data System (ADS)
Duncan, Roger G.; Fielder, Robert S.; Seeley, Ryan J.; Kozikowski, Carrie L.; Raum, Matthew T.
2005-02-01
We report the use of distributed fiber Bragg gratings to monitor thermal conditions within a simulated nuclear reactor core located at the Early Flight Fission Test Facility of the NASA Marshall Space Flight Center. Distributed fiber-optic temperature measurements promise to add significant capability and advance the state-of-the-art in high-temperature sensing. For the work reported herein, seven probes were constructed with ten sensors each for a total of 70 sensor locations throughout the core. These discrete temperature sensors were monitored over a nine hour period while the test article was heated to over 700 °C and cooled to ambient through two operational cycles. The sensor density available permits a significantly elevated understanding of thermal effects within the simulated reactor. Fiber-optic sensor performance is shown to compare very favorably with co-located thermocouples where such co-location was feasible.
Quantifying light exposure patterns in young adult students
NASA Astrophysics Data System (ADS)
Alvarez, Amanda A.; Wildsoet, Christine F.
2013-08-01
Exposure to bright light appears to be protective against myopia in both animals (chicks, monkeys) and children, but quantitative data on human light exposure are limited. In this study, we report on a technique for quantifying light exposure using wearable sensors. Twenty-seven young adult subjects wore a light sensor continuously for two weeks during one of three seasons, and also completed questionnaires about their visual activities. Light data were analyzed with respect to refractive error and season, and the objective sensor data were compared with subjects' estimates of time spent indoors and outdoors. Subjects' estimates of time spent indoors and outdoors were in poor agreement with durations reported by the sensor data. The results of questionnaire-based studies of light exposure should thus be interpreted with caution. The role of light in refractive error development should be investigated using multiple methods such as sensors to complement questionnaires.
Quantifying light exposure patterns in young adult students
Alvarez, Amanda A.; Wildsoet, Christine F.
2014-01-01
Exposure to bright light appears to be protective against myopia in both animals (chicks, monkeys) and children, but quantitative data on human light exposure are limited. In this study, we report on a technique for quantifying light exposure using wearable sensors. Twenty-seven young adult subjects wore a light sensor continuously for two weeks during one of three seasons, and also completed questionnaires about their visual activities. Light data were analyzed with respect to refractive error and season, and the objective sensor data were compared with subjects’ estimates of time spent indoors and outdoors. Subjects’ estimates of time spent indoors and outdoors were in poor agreement with durations reported by the sensor data. The results of questionnaire-based studies of light exposure should thus be interpreted with caution. The role of light in refractive error development should be investigated using multiple methods such as sensors to complement questionnaires. PMID:25342873
H2 S Sensors: Fumarate-Based fcu-MOF Thin Film Grown on a Capacitive Interdigitated Electrode.
Yassine, Omar; Shekhah, Osama; Assen, Ayalew H; Belmabkhout, Youssef; Salama, Khaled N; Eddaoudi, Mohamed
2016-12-19
Herein we report the fabrication of an advanced sensor for the detection of hydrogen sulfide (H 2 S) at room temperature, using thin films of rare-earth metal (RE)-based metal-organic framework (MOF) with underlying fcu topology. This unique MOF-based sensor is made via the in situ growth of fumarate-based fcu-MOF (fum-fcu-MOF) thin film on a capacitive interdigitated electrode. The sensor showed a remarkable detection sensitivity for H 2 S at concentrations down to 100 ppb, with the lower detection limit around 5 ppb. The fum-fcu-MOF sensor exhibits a highly desirable detection selectivity towards H 2 S vs. CH 4 , NO 2 , H 2 , and C 7 H 8 as well as an outstanding H 2 S sensing stability as compared to other reported MOFs. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
DNA as Sensors and Imaging Agents for Metal Ions
Xiang, Yu
2014-01-01
Increasing interests in detecting metal ions in many chemical and biomedical fields have created demands for developing sensors and imaging agents for metal ions with high sensitivity and selectivity. This review covers recent progress in DNA-based sensors and imaging agents for metal ions. Through both combinatorial selection and rational design, a number of metal ion-dependent DNAzymes and metal ion-binding DNA structures that can selectively recognize specific metal ions have been obtained. By attaching these DNA molecules with signal reporters such as fluorophores, chromophores, electrochemical tags, and Raman tags, a number of DNA-based sensors for both diamagnetic and paramagnetic metal ions have been developed for fluorescent, colorimetric, electrochemical, and surface Raman detections. These sensors are highly sensitive (with detection limit down to 11 ppt) and selective (with selectivity up to millions-fold) toward specific metal ions. In addition, through further development to simplify the operation, such as the use of “dipstick tests”, portable fluorometers, computer-readable discs, and widely available glucose meters, these sensors have been applied for on-site and real-time environmental monitoring and point-of-care medical diagnostics. The use of these sensors for in situ cellular imaging has also been reported. The generality of the combinatorial selection to obtain DNAzymes for almost any metal ion in any oxidation state, and the ease of modification of the DNA with different signal reporters make DNA an emerging and promising class of molecules for metal ion sensing and imaging in many fields of applications. PMID:24359450
High Sensitivity MEMS Strain Sensor: Design and Simulation
Mohammed, Ahmed A. S.; Moussa, Walied A.; Lou, Edmond
2008-01-01
In this article, we report on the new design of a miniaturized strain microsensor. The proposed sensor utilizes the piezoresistive properties of doped single crystal silicon. Employing the Micro Electro Mechanical Systems (MEMS) technology, high sensor sensitivities and resolutions have been achieved. The current sensor design employs different levels of signal amplifications. These amplifications include geometric, material and electronic levels. The sensor and the electronic circuits can be integrated on a single chip, and packaged as a small functional unit. The sensor converts input strain to resistance change, which can be transformed to bridge imbalance voltage. An analog output that demonstrates high sensitivity (0.03mV/με), high absolute resolution (1με) and low power consumption (100μA) with a maximum range of ±4000με has been reported. These performance characteristics have been achieved with high signal stability over a wide temperature range (±50°C), which introduces the proposed MEMS strain sensor as a strong candidate for wireless strain sensing applications under harsh environmental conditions. Moreover, this sensor has been designed, verified and can be easily modified to measure other values such as force, torque…etc. In this work, the sensor design is achieved using Finite Element Method (FEM) with the application of the piezoresistivity theory. This design process and the microfabrication process flow to prototype the design have been presented. PMID:27879841
A Graphene-Based Resistive Pressure Sensor with Record-High Sensitivity in a Wide Pressure Range
Tian, He; Shu, Yi; Wang, Xue-Feng; Mohammad, Mohammad Ali; Bie, Zhi; Xie, Qian-Yi; Li, Cheng; Mi, Wen-Tian; Yang, Yi; Ren, Tian-Ling
2015-01-01
Pressure sensors are a key component in electronic skin (e-skin) sensing systems. Most reported resistive pressure sensors have a high sensitivity at low pressures (<5 kPa) to enable ultra-sensitive detection. However, the sensitivity drops significantly at high pressures (>5 kPa), which is inadequate for practical applications. For example, actions like a gentle touch and object manipulation have pressures below 10 kPa, and 10–100 kPa, respectively. Maintaining a high sensitivity in a wide pressure range is in great demand. Here, a flexible, wide range and ultra-sensitive resistive pressure sensor with a foam-like structure based on laser-scribed graphene (LSG) is demonstrated. Benefitting from the large spacing between graphene layers and the unique v-shaped microstructure of the LSG, the sensitivity of the pressure sensor is as high as 0.96 kPa−1 in a wide pressure range (0 ~ 50 kPa). Considering both sensitivity and pressure sensing range, the pressure sensor developed in this work is the best among all reported pressure sensors to date. A model of the LSG pressure sensor is also established, which agrees well with the experimental results. This work indicates that laser scribed flexible graphene pressure sensors could be widely used for artificial e-skin, medical-sensing, bio-sensing and many other areas. PMID:25721159
Solid State Gas Sensor Research in Germany – a Status Report
Moos, Ralf; Sahner, Kathy; Fleischer, Maximilian; Guth, Ulrich; Barsan, Nicolae; Weimar, Udo
2009-01-01
This status report overviews activities of the German gas sensor research community. It highlights recent progress in the field of potentiometric, amperometric, conductometric, impedimetric, and field effect-based gas sensors. It is shown that besides step-by-step improvements of conventional principles, e.g. by the application of novel materials, novel principles turned out to enable new markets. In the field of mixed potential gas sensors, novel materials allow for selective detection of combustion exhaust components. The same goal can be reached by using zeolites for impedimetric gas sensors. Operando spectroscopy is a powerful tool to learn about the mechanisms in n-type and in p-type conductometric sensors and to design knowledge-based improved sensor devices. Novel deposition methods are applied to gain direct access to the material morphology as well as to obtain dense thick metal oxide films without high temperature steps. Since conductometric and impedimetric sensors have the disadvantage that a current has to pass the gas sensitive film, film morphology, electrode materials, and geometrical issues affect the sensor signal. Therefore, one tries to measure directly the Fermi level position either by measuring the gas-dependent Seebeck coefficient at high temperatures or at room temperature by applying a modified miniaturized Kelvin probe method, where surface adsorption-based work function changes drive the drain-source current of a field effect transistor. PMID:22408529
NASA Astrophysics Data System (ADS)
Yu, Gui-Feng; Yan, Xu; Yu, Miao; Jia, Meng-Yang; Pan, Wei; He, Xiao-Xiao; Han, Wen-Peng; Zhang, Zhi-Ming; Yu, Liang-Min; Long, Yun-Ze
2016-01-01
A facile fabrication strategy via electrospinning and followed by in situ polymerization to fabricate a patterned, highly stretchable, and conductive polyaniline/poly(vinylidene fluoride) (PANI/PVDF) nanofibrous membrane is reported. Owing to the patterned structure, the nanofibrous PANI/PVDF strain sensor can detect a strain up to 110%, for comparison, which is 2.6 times higher than the common nonwoven PANI/PVDF mat and much larger than the previously reported values (usually less than 15%). Meanwhile, the conductivity of the patterned strain sensor shows a linear response to the applied strain in a wide range from 0% to about 85%. Additionally, the patterned PANI/PVDF strain sensor can completely recover to its original electrical and mechanical values within a strain range of more than 22%, and exhibits good durability over 10 000 folding-unfolding tests. Furthermore, the strain sensor also can be used to detect finger motion. The results demonstrate promising application of the patterned nanofibrous membrane in flexible electronic fields.A facile fabrication strategy via electrospinning and followed by in situ polymerization to fabricate a patterned, highly stretchable, and conductive polyaniline/poly(vinylidene fluoride) (PANI/PVDF) nanofibrous membrane is reported. Owing to the patterned structure, the nanofibrous PANI/PVDF strain sensor can detect a strain up to 110%, for comparison, which is 2.6 times higher than the common nonwoven PANI/PVDF mat and much larger than the previously reported values (usually less than 15%). Meanwhile, the conductivity of the patterned strain sensor shows a linear response to the applied strain in a wide range from 0% to about 85%. Additionally, the patterned PANI/PVDF strain sensor can completely recover to its original electrical and mechanical values within a strain range of more than 22%, and exhibits good durability over 10 000 folding-unfolding tests. Furthermore, the strain sensor also can be used to detect finger motion. The results demonstrate promising application of the patterned nanofibrous membrane in flexible electronic fields. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08618c
Networking Sensors for Information Dominance - Joint Signal Processing and Communication Design
2012-01-01
2012 4. TITLE AND SUBTITLE NETWORKING SENSORS FOR INFORMATION DOMINANCE - JOINT SIGNAL PROCESSING AND COMMUNICATION DESIGN, Final Report for FA9550...Rev. 2-89) Prescribed by ANSI Std. Z39-18 298-102 Public A AFRL-OSR-VA-TR-2012-0729 NETWORKING SENSORS FOR INFORMATION DOMINANCE - JOINT
NASA Technical Reports Server (NTRS)
Kindle, E. C.; Condon, E.; Casas, J.
1976-01-01
The research to develop the capabilities for sensing air pollution constituencies using satellite or airborne remote sensors is reported. Sensor evaluation and calibration are analyzed including data reduction. The proposed follow-on research is presented.
Large-area graphene for sensor applications
NASA Astrophysics Data System (ADS)
Snow, Eric S.
2010-04-01
Graphene represents an important new material with potential Department of Defense sensor applications. At the Naval Research Laboratory we have developed three techniques to produce large-area graphene films. We have used this material to construct chemical and radio-frequency electromagnetic sensors. Here we report the initial results of this effort.
Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide
This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in...
Performance of a wireless sensor network for crop monitoring and irrigation control
USDA-ARS?s Scientific Manuscript database
Robust automatic irrigation scheduling has been demonstrated using wired sensors and sensor network systems with subsurface drip and moving irrigation systems. However, there are limited studies that report on crop yield and water use efficiency resulting from the use of wireless networks to automat...
Fiber optic micromirror sensor for volatile organic compounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler, M.A.; Ricco, A.J.; Buss, R.
With the growing concern over environmental pollution, there is a need for sensors to locate and measure the distribution of a wide range of pollutants. In this paper the authors report a fiber optic sensor, based on a thin film micromirror, which responds to a wide range of volatile organic compounds (VOCs). This generic class of sensor will be useful for monitoring applications where the pollutant has already been identified.
Distributed Detection with Collisions in a Random, Single-Hop Wireless Sensor Network
2013-05-26
public release; distribution is unlimited. Distributed detection with collisions in a random, single-hop wireless sensor network The views, opinions...1274 2 ABSTRACT Distributed detection with collisions in a random, single-hop wireless sensor network Report Title We consider the problem of... WIRELESS SENSOR NETWORK Gene T. Whipps?† Emre Ertin† Randolph L. Moses† ?U.S. Army Research Laboratory, Adelphi, MD 20783 †The Ohio State University
Avoiding space robot collisions utilizing the NASA/GSFC tri-mode skin sensor
NASA Technical Reports Server (NTRS)
Prinz, F. B.
1991-01-01
Sensor based robot motion planning research has primarily focused on mobile robots. Consider, however, the case of a robot manipulator expected to operate autonomously in a dynamic environment where unexpected collisions can occur with many parts of the robot. Only a sensor based system capable of generating collision free paths would be acceptable in such situations. Recently, work in this area has been reported in which a deterministic solution for 2DOF systems has been generated. The arm was sensitized with 'skin' of infra-red sensors. We have proposed a heuristic (potential field based) methodology for redundant robots with large DOF's. The key concepts are solving the path planning problem by cooperating global and local planning modules, the use of complete information from the sensors and partial (but appropriate) information from a world model, representation of objects with hyper-ellipsoids in the world model, and the use of variational planning. We intend to sensitize the robot arm with a 'skin' of capacitive proximity sensors. These sensors were developed at NASA, and are exceptionally suited for the space application. In the first part of the report, we discuss the development and modeling of the capacitive proximity sensor. In the second part we discuss the motion planning algorithm.
Evaluating the performance of low cost chemical sensors for air pollution research.
Lewis, Alastair C; Lee, James D; Edwards, Peter M; Shaw, Marvin D; Evans, Mat J; Moller, Sarah J; Smith, Katie R; Buckley, Jack W; Ellis, Matthew; Gillot, Stefan R; White, Andrew
2016-07-18
Low cost pollution sensors have been widely publicized, in principle offering increased information on the distribution of air pollution and a democratization of air quality measurements to amateur users. We report a laboratory study of commonly-used electrochemical sensors and quantify a number of cross-interferences with other atmospheric chemicals, some of which become significant at typical suburban air pollution concentrations. We highlight that artefact signals from co-sampled pollutants such as CO2 can be greater than the electrochemical sensor signal generated by the measurand. We subsequently tested in ambient air, over a period of three weeks, twenty identical commercial sensor packages alongside standard measurements and report on the degree of agreement between references and sensors. We then explore potential experimental approaches to improve sensor performance, enhancing outputs from qualitative to quantitative, focusing on low cost VOC photoionization sensors. Careful signal handling, for example, was seen to improve limits of detection by one order of magnitude. The quantity, magnitude and complexity of analytical interferences that must be characterised to convert a signal into a quantitative observation, with known uncertainties, make standard individual parameter regression inappropriate. We show that one potential solution to this problem is the application of supervised machine learning approaches such as boosted regression trees and Gaussian processes emulation.
2012-07-01
Engineering Service Center, Port Hueneme, CA Robert Kirgan, Army Environmental Command Doug Maddox, US Environmental Protection Agency Doug Murray...FINAL REPORT MUNITIONS CLASSIFICATION WITH PORTABLE ADVANCED ELECTROMAGNETIC SENSORS Demonstration at the former Camp Beale, CA , Summer...if it does not display a currently valid OMB control number. 1. REPORT DATE JUL 2012 2 . REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND
2012-03-01
collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE MAR 2012 2 . REPORT TYPE 3. DATES COVERED...1 1.4 IMPLEMENTATION ISSUES .............................................................................. 2 2.0...assembled sensor with end caps attached. ................................................................................ 5 Figure 2 . Construction details
Daamen, Ruby C.; Edwin A. Roehl, Jr.; Conrads, Paul
2010-01-01
A technology often used for industrial applications is “inferential sensor.” Rather than installing a redundant sensor to measure a process, such as an additional waterlevel gage, an inferential sensor, or virtual sensor, is developed that estimates the processes measured by the physical sensor. The advantage of an inferential sensor is that it provides a redundant signal to the sensor in the field but without exposure to environmental threats. In the event that a gage does malfunction, the inferential sensor provides an estimate for the period of missing data. The inferential sensor also can be used in the quality assurance and quality control of the data. Inferential sensors for gages in the EDEN network are currently (2010) under development. The inferential sensors will be automated so that the real-time EDEN data will continuously be compared to the inferential sensor signal and digital reports of the status of the real-time data will be sent periodically to the appropriate support personnel. The development and application of inferential sensors is easily transferable to other real-time hydrologic monitoring networks.
Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period.
Profit, Deborah; Rohatagi, Shashank; Zhao, Cathy; Hatch, Ainslie; Docherty, John P; Peters-Strickland, Timothy S
2016-09-01
A digital medicine system (DMS) has been developed to measure and report adherence to an atypical antipsychotic, aripiprazole, in psychiatric patients. The DMS consists of 3 components: ingestible sensor embedded in a medication tablet, wearable sensor, and secure mobile and cloud-based applications. An umbrella study protocol was designed to rapidly assess the technical performance and safety of the DMS in multiple substudies to guide the technology development. Two sequential substudies enrolled 30 and 29 healthy volunteers between March-April 2014 and February-March 2015, respectively, to assess detection accuracy of the ingestible sensor by the DMS and the latency period between ingestion and detection of the ingestion by the wearable sensor or the cloud-based server. The first substudy identified areas for improvement using early versions of the wearable sensor and the mobile application. The second substudy tested updated versions of the components and showed an overall ingestion detection rate of 96.6%. Mean latency times for the signal transmission were 1.1-1.3 minutes (from ingestion to the wearable sensor detection) and 6.2-10.3 minutes (from the wearable sensor detection to the server detection). Half of transmissions were completed in < 2 minutes, and ~90% of ingestions were registered by the smartphone within 30 minutes of ingestion. No serious adverse events, discontinuations, or clinically significant laboratory/vital signs findings were reported. The DMS implementing modified versions of the smartphone application and the wearable sensor has the technical capability to detect and report tablet ingestion with high accuracy and acceptable latency time. ClinicalTrials.gov identifier: NCT02091882. © Copyright 2016 Physicians Postgraduate Press, Inc.
Robert, Clélia; Michau, Vincent; Fleury, Bruno; Magli, Serge; Vial, Laurent
2012-07-02
Adaptive optics provide real-time compensation for atmospheric turbulence. The correction quality relies on a key element: the wavefront sensor. We have designed an adaptive optics system in the mid-infrared range providing high spatial resolution for ground-to-air applications, integrating a Shack-Hartmann infrared wavefront sensor operating on an extended source. This paper describes and justifies the design of the infrared wavefront sensor, while defining and characterizing the Shack-Hartmann wavefront sensor camera. Performance and illustration of field tests are also reported.
1991-05-01
AD-A237 045 MP I ENVIRONMENTAL SITE CHARACTERIZATION of EFOR THE WIDE AREA MINE SENSOR DEMONSTRATION, ABERDEEN PROVING GROUND , OCTOBER 1988 T- by...Wide Area Mine Sensor Demonstration, Aberdeen Proving Ground , October 1988 6. AUTHOR(S) Bruce M. Sabol, Thomas E. Berry, Ben L. Garnes 7. PERFORMING... Proving Ground (APG), Maryland. This report presents data that characterize terrain and environmental factors expected to affect WAN sensor performance
Fiber-optic sensors for aerospace electrical measurements: An update
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Rose, A. H.; Tang, D.; Day, G. W.
1991-01-01
Fiber-optic sensors are being developed for electrical current, voltage, and power measurements in aerospace applications. These sensors are presently designed to cover ac frequencies from 60 Hz to 20 kHz. The current sensor, based on the Faraday effect in optical fiber, is in advanced development after some initial testing. Concentration is on packaging methods and ways to maintain consistent sensitivity with changes in temperature. The voltage sensor, utilizing the Pockels effect in a crystal, has excelled in temperature tests. This paper reports on the development of these sensors, the results of evaluation, improvements now in progress, and the future direction of the work.
Quantitative imaging with fluorescent biosensors.
Okumoto, Sakiko; Jones, Alexander; Frommer, Wolf B
2012-01-01
Molecular activities are highly dynamic and can occur locally in subcellular domains or compartments. Neighboring cells in the same tissue can exist in different states. Therefore, quantitative information on the cellular and subcellular dynamics of ions, signaling molecules, and metabolites is critical for functional understanding of organisms. Mass spectrometry is generally used for monitoring ions and metabolites; however, its temporal and spatial resolution are limited. Fluorescent proteins have revolutionized many areas of biology-e.g., fluorescent proteins can report on gene expression or protein localization in real time-yet promoter-based reporters are often slow to report physiologically relevant changes such as calcium oscillations. Therefore, novel tools are required that can be deployed in specific cells and targeted to subcellular compartments in order to quantify target molecule dynamics directly. We require tools that can measure enzyme activities, protein dynamics, and biophysical processes (e.g., membrane potential or molecular tension) with subcellular resolution. Today, we have an extensive suite of tools at our disposal to address these challenges, including translocation sensors, fluorescence-intensity sensors, and Förster resonance energy transfer sensors. This review summarizes sensor design principles, provides a database of sensors for more than 70 different analytes/processes, and gives examples of applications in quantitative live cell imaging.
Building Intrusion Detection with a Wireless Sensor Network
NASA Astrophysics Data System (ADS)
Wälchli, Markus; Braun, Torsten
This paper addresses the detection and reporting of abnormal building access with a wireless sensor network. A common office room, offering space for two working persons, has been monitored with ten sensor nodes and a base station. The task of the system is to report suspicious office occupation such as office searching by thieves. On the other hand, normal office occupation should not throw alarms. In order to save energy for communication, the system provides all nodes with some adaptive short-term memory. Thus, a set of sensor activation patterns can be temporarily learned. The local memory is implemented as an Adaptive Resonance Theory (ART) neural network. Unknown event patterns detected on sensor node level are reported to the base station, where the system-wide anomaly detection is performed. The anomaly detector is lightweight and completely self-learning. The system can be run autonomously or it could be used as a triggering system to turn on an additional high-resolution system on demand. Our building monitoring system has proven to work reliably in different evaluated scenarios. Communication costs of up to 90% could be saved compared to a threshold-based approach without local memory.
Achromatic-chromatic colorimetric sensors for on-off type detection of analytes.
Heo, Jun Hyuk; Cho, Hui Hun; Lee, Jin Woong; Lee, Jung Heon
2014-12-21
We report the development of achromatic colorimetric sensors; sensors changing their colors from achromatic black to other chromatic colors. An achromatic colorimetric sensor was prepared by mixing a general colorimetric indicator, whose color changes between chromatic colors, and a complementary colored dye with no reaction to the targeted analyte. As the color of an achromatic colorimetric sensor changes from black to a chromatic color, the color change could be much easily recognized than general colorimetric sensors with naked eyes. More importantly, the achromatic colorimetric sensors enable on-off type recognition of the presence of analytes, which have not been achieved from most colorimetric sensors. In addition, the color changes from some achromatic colorimetric sensors (achromatic Eriochrome Black T and achromatic Benedict's solution) could be recognized with naked eyes at much lower concentration ranges than normal chromatic colorimetric sensors. These results provide new opportunities in the use of colorimetric sensors for diverse applications, such as harsh industrial, environmental, and biological detection.
2009-12-01
independent information on each individual radar pulse that is incident upon an illuminated RF tag/transponder. As such, data-rates commensurate with...Final Report Office of Naval Research Program Manager: Dr. Rabinder Madan Project Title: Waveform-Diverse Sensors Award # N00014-06-1-0004...multistatic, pulse compression, waveform diversity, DOA estimation 16. SECURITY CLASSIFICATION OF: a. REPORT b. ABSTRACT c. THIS PAGE 17. LIMITATION
A wireless sensor tag platform for container security and integrity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amaya, Ivan A.; Cree, Johnathan V.; Mauss, Fredrick J.
Cargo containers onboard ships are widely used in the global supply chain. The need for container security is evidenced by the Container Security Initiative launched by the U.S. Bureau of Customs and Border Protection (CBP). One method of monitoring cargo containers is using low power wireless sensor tags. The wireless sensor tags are used to set up a network that is comprised of tags internal to the container and a central device. The sensor network reports alarms and other anomalies to a central device, which then relays the message to an outside network upon arrival at the destination port. Thismore » allows the port authorities to have knowledge of potential security or integrity issues before physically examining the container. Challenges of using wireless sensor tag networks for container security include battery life, size, environmental conditions, information security, and cost among others. PNNL developed an active wireless sensor tag platform capable of reporting data wirelessly to a central node as well as logging data to nonvolatile memory. The tags, operate at 2.4 GHz over an IEEE 802.15.4 protocol, and were designed to be distributed throughout the inside of a shipping container in the upper support frame. The tags are mounted in a housing that allows for simple and efficient installation or removal prior to, during, or after shipment. The distributed tags monitor the entire container volume. The sensor tag platform utilizes low power electronics and provides an extensible sensor interface for incorporating a wide range of sensors including chemical, biological, and environmental sensors.« less
A wireless sensor tag platform for container security and integrity
NASA Astrophysics Data System (ADS)
Amaya, Ivan A.; Cree, Johnathan V.; Mauss, Fredrick J.
2011-04-01
Cargo containers onboard ships are widely used in the global supply chain. The need for container security is evidenced by the Container Security Initiative launched by the U.S. Bureau of Customs and Border Protection (CBP). One method of monitoring cargo containers is using low power wireless sensor tags. The wireless sensor tags are used to set up a network that is comprised of tags internal to the container and a central device. The sensor network reports alarms and other anomalies to a central device, which then relays the message to an outside network upon arrival at the destination port. This allows the port authorities to have knowledge of potential security or integrity issues before physically examining the container. Challenges of using wireless sensor tag networks for container security include battery life, size, environmental conditions, information security, and cost among others. PNNL developed an active wireless sensor tag platform capable of reporting data wirelessly to a central node as well as logging data to nonvolatile memory. The tags, operate at 2.4 GHz over an IEEE 802.15.4 protocol, and were designed to be distributed throughout the inside of a shipping container in the upper support frame. The tags are mounted in a housing that allows for simple and efficient installation or removal prior to, during, or after shipment. The distributed tags monitor the entire container volume. The sensor tag platform utilizes low power electronics and provides an extensible sensor interface for incorporating a wide range of sensors including chemical, biological, and environmental sensors.
Dehennis, Andrew; Mortellaro, Mark A; Ioacara, Sorin
2015-07-29
Continuous glucose monitoring (CGM), which enables real-time glucose display and trend information as well as real-time alarms, can improve glycemic control and quality of life in patients with diabetes mellitus. Previous reports have described strategies to extend the useable lifetime of a single sensor from 1-2 weeks to 28 days. The present multisite study describes the characterization of a sensing platform achieving 90 days of continuous use for a single, fully implanted sensor. The Senseonics CGM system is composed of a long-term implantable glucose sensor and a wearable smart transmitter. Study subjects underwent subcutaneous implantation of sensors in the upper arm. Eight-hour clinic sessions were performed every 14 days, during which sensor glucose values were compared against venous blood lab reference measurements collected every 15 minutes using mean absolute relative differences (MARDs). All subjects (mean ± standard deviation age: 43.5 ± 11.0 years; with 10 sensors inserted in men and 14 in women) had type 1 diabetes mellitus. Most (22 of 24) sensors reported glucose values for the entire 90 days. The MARD value was 11.4 ± 2.7% (range, 8.1-19.5%) for reference glucose values between 40-400 mg/dl. There was no significant difference in MARD throughout the 90-day study (P = .31). No serious adverse events were noted. The Senseonics CGM, composed of an implantable sensor, external smart transmitter, and smartphone app, is the first system that uses a single sensor for continuous display of accurate glucose values for 3 months. © 2015 Diabetes Technology Society.
Surface plasmon resonance based fiber optic pH sensor utilizing Ag/ITO/Al/hydrogel layers.
Mishra, Satyendra K; Gupta, Banshi D
2013-05-07
The fabrication and characterization of a surface plasmon resonance based pH sensor using coatings of silver, ITO (In2O3:SnO2), aluminium and smart hydrogel layers over an unclad core of an optical fiber have been reported. The silver, aluminium and ITO layers were coated using a thermal evaporation technique, while the hydrogel layer was prepared using a dip-coating method. The sensor works on the principle of detecting changes in the refractive index of the hydrogel layer due to its swelling and shrinkage caused by changes in the pH of the fluid surrounding the hydrogel layer. The sensor utilizes a wavelength interrogation technique and operates in a particular window of low and high pH values. Increasing the pH value of the fluid causes swelling of the hydrogel layer, which decreases its refractive index and results in a shift of the resonance wavelength towards blue in the transmitted spectra. The thicknesses of the ITO and aluminium layers have been optimized to achieve the best performance of the sensor. The ITO layer increases the sensitivity while the aluminium layer increases the detection accuracy of the sensor. The proposed sensor possesses maximum sensitivity in comparison to the sensors reported in the literature. A negligible effect of ambient temperature in the range 25 °C to 45 °C on the performance of the sensor has been observed. The additional advantages of the sensor are short response time, low cost, probe miniaturization, probe re-usability and the capability of remote sensing.
Towards an autonomous sensor architecture for persistent area protection
NASA Astrophysics Data System (ADS)
Thomas, Paul A.; Marshall, Gillian F.; Stubbins, Daniel J.; Faulkner, David A.
2016-10-01
The majority of sensor installations for area protection (e.g. critical national infrastructure, military forward operating bases, etc.) make use of banks of screens each containing one or more sensor feeds, such that the burden of combining data from the various sources, understanding the situation, and controlling the sensors all lies with the human operator. Any automation in the system is generally heavily bespoke for the particular installation, leading to an inflexible system which is difficult to change or upgrade. We have developed a modular system architecture consisting of intelligent autonomous sensor modules, a high level decision making module, a middleware integration layer and an end-user GUI. The modules are all effectively "plug and play", and we have demonstrated that it is relatively simple to incorporate legacy sensors into the architecture. We have extended our previously-reported SAPIENT demonstration system to operate with a larger number and variety of sensor modules, over an extended area, detecting and classifying a wider variety of "threat activities", both vehicular and pedestrian. We report the results of a demonstration of the SAPIENT system containing multiple autonomous sensor modules with a range of modalities including laser scanners, radar, TI, EO, acoustic and seismic sensors. They operate from a combination of mains, generator and battery power, and communicate with the central "hub" over Ethernet, point-to-point wireless links and Wi-Fi. The system has been configured to protect an extended area in a complex semi-urban environment. We discuss the operation of the SAPIENT system in a realistic demonstration environment (which included significant activity not under trial control), showing sensor cueing, multi-modal sensor fusion, threat prioritisation and target hand-off.
Usha, Sruthi P; Gupta, Banshi D
2018-03-15
A lossy mode resonance (LMR) based sensor for urinary p-cresol testing on optical fiber substrate is developed. The sensor probe fabrication includes dip coating of nanocomposite layer of zinc oxide and molybdenum sulphide (ZnO/MoS 2 ) over unclad core of optical fiber as the transducer layer followed by the layer of molecular imprinted polymer (MIP) as the recognition medium. The addition of molybdenum sulphide in the transducer layer increases the absorption of light in the medium which enhances the LMR properties of zinc oxide thereby increasing the conductivity and hence the sensitivity of the sensor. The sensor probe is characterized for p-cresol concentration range from 0µM (reference sample) to 1000µM in artificially prepared urine. Optimizations of various probe fabrication parameters are carried to bring out the sensor's optimal performance with a sensitivity of 11.86nm/µM and 28nM as the limit of detection (LOD). A two-order improvement in LOD is obtained as compared to the recently reported p-cresol sensor. The proposed sensor possesses a response time of 15s which is 8 times better than that reported in the literature utilizing electrochemical method. Its response time is also better than the p-cresol sensor currently available in the market for the medical field. Thus, with a fast response, significant stability and repeatability, the proposed sensor holds practical implementation possibilities in the medical field. Further, the realization of sensor probe over optical fiber substrate adds remote sensing and online monitoring feasibilities. Copyright © 2017 Elsevier B.V. All rights reserved.
Aircraft Cabin Environmental Quality Sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gundel, Lara; Kirchstetter, Thomas; Spears, Michael
2010-05-06
The Indoor Environment Department at Lawrence Berkeley National Laboratory (LBNL) teamed with seven universities to participate in a Federal Aviation Administration (FAA) Center of Excellence (COE) for research on environmental quality in aircraft. This report describes research performed at LBNL on selecting and evaluating sensors for monitoring environmental quality in aircraft cabins, as part of Project 7 of the FAA's COE for Airliner Cabin Environmental Research (ACER)1 effort. This part of Project 7 links to the ozone, pesticide, and incident projects for data collection and monitoring and is a component of a broader research effort on sensors by ACER. Resultsmore » from UCB and LBNL's concurrent research on ozone (ACER Project 1) are found in Weschler et al., 2007; Bhangar et al. 2008; Coleman et al., 2008 and Strom-Tejsen et al., 2008. LBNL's research on pesticides (ACER Project 2) in airliner cabins is described in Maddalena and McKone (2008). This report focused on the sensors needed for normal contaminants and conditions in aircraft. The results are intended to complement and coordinate with results from other ACER members who concentrated primarily on (a) sensors for chemical and biological pollutants that might be released intentionally in aircraft; (b) integration of sensor systems; and (c) optimal location of sensors within aircraft. The parameters and sensors were selected primarily to satisfy routine monitoring needs for contaminants and conditions that commonly occur in aircraft. However, such sensor systems can also be incorporated into research programs on environmental quality in aircraft cabins.« less
NASA Astrophysics Data System (ADS)
Ahmed, Riaz; Banerjee, Sourav
2018-02-01
In this article, an extremely versatile predictive model for a newly developed Basilar meta-Membrane (BM2) sensors is reported with variable engineering parameters that contribute to it's frequency selection capabilities. The predictive model reported herein is for advancement over existing method by incorporating versatile and nonhomogeneous (e.g. functionally graded) model parameters that could not only exploit the possibilities of creating complex combinations of broadband frequency sensors but also explain the unique unexplained physical phenomenon that prevails in BM2, e.g. tailgating waves. In recent years, few notable attempts were made to fabricate the artificial basilar membrane, mimicking the mechanics of the human cochlea within a very short range of frequencies. To explain the operation of these sensors a few models were proposed. But, we fundamentally argue the "fabrication to explanation" approach and proposed the model driven predictive design process for the design any (BM2) as broadband sensors. Inspired by the physics of basilar membrane, frequency domain predictive model is proposed where both the material and geometrical parameters can be arbitrarily varied. Broadband frequency is applicable in many fields of science, engineering and technology, such as, sensors for chemical, biological and acoustic applications. With the proposed model, which is three times faster than its FEM counterpart, it is possible to alter the attributes of the selected length of the designed sensor using complex combinations of model parameters, based on target frequency applications. Finally, the tailgating wave peaks in the artificial basilar membranes that prevails in the previously reported experimental studies are also explained using the proposed model.
Elliott, Michael R; Margulies, Susan S; Maltese, Matthew R; Arbogast, Kristy B
2015-09-18
There has been recent dramatic increase in the use of sensors affixed to the heads or helmets of athletes to measure the biomechanics of head impacts that lead to concussion. The relationship between injury and linear or rotational head acceleration measured by such sensors can be quantified with an injury risk curve. The utility of the injury risk curve relies on the accuracy of both the clinical diagnosis and the biomechanical measure. The focus of our analysis was to demonstrate the influence of three sources of error on the shape and interpretation of concussion injury risk curves: sampling variability associated with a rare event, concussion under-reporting, and sensor measurement error. We utilized Bayesian statistical methods to generate synthetic data from previously published concussion injury risk curves developed using data from helmet-based sensors on collegiate football players and assessed the effect of the three sources of error on the risk relationship. Accounting for sampling variability adds uncertainty or width to the injury risk curve. Assuming a variety of rates of unreported concussions in the non-concussed group, we found that accounting for under-reporting lowers the rotational acceleration required for a given concussion risk. Lastly, after accounting for sensor error, we find strengthened relationships between rotational acceleration and injury risk, further lowering the magnitude of rotational acceleration needed for a given risk of concussion. As more accurate sensors are designed and more sensitive and specific clinical diagnostic tools are introduced, our analysis provides guidance for the future development of comprehensive concussion risk curves. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Levente
Interpreting sensor data require knowledge about sensor placement and the surrounding environment. For a single sensor measurement, it is easy to document the context by visual observation, however for millions of sensors reporting data back to a server, the contextual information needs to be automatically extracted from either data analysis or leveraging complimentary data sources. Data layers that overlap spatially or temporally with sensor locations, can be used to extract the context and to validate the measurement. To minimize the amount of data transmitted through the internet, while preserving signal information content, two methods are explored; computation at the edgemore » and compressed sensing. We validate the above methods on wind and chemical sensor data (1) eliminate redundant measurement from wind sensors and (2) extract peak value of a chemical sensor measuring a methane plume. We present a general cloud based framework to validate sensor data based on statistical and physical modeling and contextual data extracted from geospatial data.« less
Fundamental concepts of integrated and fiber optic sensors
NASA Technical Reports Server (NTRS)
Tuma, Margaret L.
1995-01-01
This chapter discusses fiber optic and integrated optic sensor concepts. Unfortunately, there is no standard method to categorize these sensor concepts. Here, fiber optic and integrated optic sensor concepts will be categorized by the primary modulation technique. These modulation techniques have been classified as: intensity, phase, wavelength, polarization, and time/frequency modulation. All modulate the output light with respect to changes in the physical or chemical property to be measured. Each primary modulation technique is then divided into fiber optic and integrated optic sections which are treated independently. For each sensor concept, possible sensor applications are discussed. The sensors and references discussed are not exhaustive, but sufficient to give the reader an overview of sensor concepts developed to date. Sensor multiplexing techniques such as wavelength division, time division, and frequency division will not be discussed as they are beyond the scope of this report.
Improved grating angular sensor for LISA and MGRS
NASA Astrophysics Data System (ADS)
Sun, Ke-Xun; Lu, Patrick; Byer, Robert L.
2009-03-01
LISA requires high precision angular beam pointing and telescope steering. In this paper, we report recent results for an improved grating angular sensor. We have achieved better than 0.2 nrad/Hz1/2 at 1 kHz with 14 mW of incident power, a factor of 5 improvement over our previously reported results. At 1 Hz we achieved 1-2 nrad/Hz1/2. We realized these improvements by enclosing the grating angular sensor assembly in a vacuum chamber and mounting the optics components on a zerodur glass plate, thereby lowering the noise floor at low frequencies. Furthermore, by upgrading the electronics and thus the detector power handing capability, we also investigated sensitivity scaling versus incident laser power. The results will benefit the design of grating angular sensors.
Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases
Tricoli, Antonio
2018-01-01
This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients’ health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed. PMID:29565315
Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases.
Tricoli, Antonio; Neri, Giovanni
2018-03-22
This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients' health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed.
Wirelessly Interrogated Wear or Temperature Sensors
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Taylor, Bryant D.
2010-01-01
Sensors for monitoring surface wear and/or temperature without need for wire connections have been developed. Excitation and interrogation of these sensors are accomplished by means of a magnetic-field-response recorder. In a sensor of the present type as in the previously reported ones, the capacitance and, thus, the resonance frequency, varies as a known function of the quantity of interest that one seeks to determine. Hence, the resonance frequency is measured and used to calculate the quantity of interest.
1990-04-01
tiltmeters and a few electric field sensors would be useful. Ancillary environmental measurements will also be needed. These should include sensors to...Applied research issues such as sensor development, technological improvements, and signal processing needs are not specifically addressed. This is... sensors of increased sensitivity. A submarine may have static magnetic and electric dipole moments caused by residual mag- netization of the machinery and
An Investigation of the Dynamic Response of a Seismically Stable Platform
1982-08-01
PAD. The controls on the -9system are of two types. A low frequency tilt control, with a 10 arc second sensitivity, 2-axis tiltmeter as sensor ...Inertial Sensors Structural Analysis Holloman AFB, NiM. Support to this effort includes structural analyses toward active servo frequency band. This report...controlled to maintain a null position of a sensitive height sensor . The 6-degree-of- freedom high frequency controls are based on seismometers as sensors
2015-12-01
AFRL-RY-WP-TR-2015-0144 COGNITIVE RADIO LOW-ENERGY SIGNAL ANALYSIS SENSOR INTEGRATED CIRCUITS (CLASIC) A Broadband Mixed-Signal Iterative Down...See additional restrictions described on inside pages STINFO COPY AIR FORCE RESEARCH LABORATORY SENSORS DIRECTORATE WRIGHT-PATTERSON AIR FORCE...Signature// TODD KASTLE, Chief Spectrum Warfare Division Sensors Directorate This report is published in the interest of scientific and technical
The Present State of Amperometric Nanowire Sensors for Chemical and Biological Detection
2006-10-01
reported for a multi(nano)wire carbon monoxide 6 sensor (17). A single gallium oxide nanowire ethanol sensor with a 2.5 second response time has also...Covington, J. A.; Gardner, J. W.; Bartlett, P. N.; Toh, C-S. Conductive polymer gate FET devices for vapour sensing. IEE Proceedings - Circuits...detecting organic vapours . Sensors and Actuators B 2001, 77 (1–2), 155–162. 48. Malliaras G.; Friend, R. An organic electronics primer. Physics
NASA Astrophysics Data System (ADS)
de Podesta, Michael; Bell, Stephanie; Underwood, Robin
2018-04-01
In both meteorological and metrological applications, it is well known that air temperature sensors are susceptible to radiative errors. However, it is not widely known that the radiative error measured by an air temperature sensor in flowing air depends upon the sensor diameter, with smaller sensors reporting values closer to true air temperature. This is not a transient effect related to sensor heat capacity, but a fluid-dynamical effect arising from heat and mass flow in cylindrical geometries. This result has been known historically and is in meteorology text books. However, its significance does not appear to be widely appreciated and, as a consequence, air temperature can be—and probably is being—widely mis-estimated. In this paper, we first review prior descriptions of the ‘sensor size’ effect from the metrological and meteorological literature. We develop a heat transfer model to describe the process for cylindrical sensors, and evaluate the predicted temperature error for a range of sensor sizes and air speeds. We compare these predictions with published predictions and measurements. We report measurements demonstrating this effect in two laboratories at NPL in which the air flow and temperature are exceptionally closely controlled. The results are consistent with the heat-transfer model, and show that the air temperature error is proportional to the square root of the sensor diameter and that, even under good laboratory conditions, it can exceed 0.1 °C for a 6 mm diameter sensor. We then consider the implications of this result. In metrological applications, errors of the order of 0.1 °C are significant, representing limiting uncertainties in dimensional and mass measurements. In meteorological applications, radiative errors can easily be much larger. But in both cases, an understanding of the diameter dependence allows assessment and correction of the radiative error using a multi-sensor technique.
NASA Technical Reports Server (NTRS)
Wiggins, Bryan C.
2007-01-01
As fossil fuel supplies decline, hydrogen is quickly becoming an increasingly important fuel source. Currently hydrogen is the prime fuel of today's space vehicles (e.g., Space Shuttle) and featured as a fuel for some prototype vehicles such as the BMW seven series model. Hydrogen is a colorless, odorless gas with a 4% lower explosive limit which makes leak detection a priority. In an effort to support the use of hydrogen, a chemochromic (color changing) sensor was developed that is robust, simple to use, and does not require active operation. It can be made into a thin tape which can be conveniently used for leak detection at flanges, valves, or outlets. Chemochromic sensors can be either reversible or irreversible; however, irreversible chemochromic sensors will be analyzed in this report. The irreversible sensor is useful during hazardous operations when personnel cannot be present. To actively monitor leaks, testing of the irreversible sensor against environmental effects was completed and results indicated this material is suitable for outdoor use in the harsh beachside environment of Kennedy Space Center. The experiments in this report will give additional results to the environmental testing by adding solid rocket booster residue as a variable. The primary motivation for these experiments is to prepare the sensors for the launch pad environment at the Kennedy Space Center. In an effort to simulate the atmosphere at the pads before and after launch, the chemochromic sensors are exposed to solid rocket residue under various conditions.
NASA Astrophysics Data System (ADS)
Karnawati, D.; Wilopo, W.; Fathani, T. F.; Fukuoka, H.; Andayani, B.
2012-12-01
A Smart Grid is a cyber-based tool to facilitate a network of sensors for monitoring and communicating the landslide hazard and providing the early warning. The sensor is designed as an electronic sensor installed in the existing monitoring and early warning instruments, and also as the human sensors which comprise selected committed-people at the local community, such as the local surveyor, local observer, member of the local task force for disaster risk reduction, and any person at the local community who has been registered to dedicate their commitments for sending reports related to the landslide symptoms observed at their living environment. This tool is designed to be capable to receive up to thousands of reports/information at the same time through the electronic sensors, text message (mobile phone), the on-line participatory web as well as various social media such as Twitter and Face book. The information that should be recorded/ reported by the sensors is related to the parameters of landslide symptoms, for example the progress of cracks occurrence, ground subsidence or ground deformation. Within 10 minutes, this tool will be able to automatically elaborate and analyse the reported symptoms to predict the landslide hazard and risk levels. The predicted level of hazard/ risk can be sent back to the network of electronic and human sensors as the early warning information. The key parameters indicating the symptoms of landslide hazard were recorded/ monitored by the electrical and the human sensors. Those parameters were identified based on the investigation on geological and geotechnical conditions, supported with the laboratory analysis. The cause and triggering mechanism of landslide in the study area was also analysed in order to define the critical condition to launch the early warning. However, not only the technical but also social system were developed to raise community awareness and commitments to serve the mission as the human sensors, which will be responsible for reporting and informing the early warning. Therefore, a community empowerment and encouragement program through public education was conducted. Strategy and approach for this program was formulated based on the socio-engineering investigation. Finally, the results of technical and social engineering investigations, have been elaborated to further enhance the performance of expert system of the Smart Grid, in order to completely establish this system as an innovative and effective tool for the landslide monitoring and early warning in tropical-developing country.
50 CFR 218.115 - Requirements for monitoring and reporting.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Narrative description of sensors and platforms utilized for marine mammal detection and timeline... sensor; (vi) Length of time observers maintained visual contact with marine mammal; (vii) Wave height...
2005-07-09
This final report summarizes the progress during the Phase I SBIR project entitled Embedded Electro - Optic Sensor Network for the On-Site Calibration...network based on an electro - optic field-detection technique (the Electro - optic Sensor Network, or ESN) for the performance evaluation of phased
Mediation of in vivo glucose sensor inflammatory response via nitric oxide release.
Gifford, Raeann; Batchelor, Melissa M; Lee, Youngmi; Gokulrangan, Giridharan; Meyerhoff, Mark E; Wilson, George S
2005-12-15
In vivo glucose sensor nitric oxide (NO) release is a means of mediating the inflammatory response that may cause sensor/tissue interactions and degraded sensor performance. The NO release (NOr) sensors were prepared by doping the outer polymeric membrane coating of previously reported needle-type electrochemical sensors with suitable lipophilic diazeniumdiolate species. The Clarke error grid correlation of sensor glycemia estimates versus blood glucose measured in Sprague-Dawley rats yielded 99.7% of the points for NOr sensors and 96.3% of points for the control within zones A and B (clinically acceptable) on Day 1, with a similar correlation for Day 3. Histological examination of the implant site demonstrated that the inflammatory response was significantly decreased for 100% of the NOr sensors at 24 h. The NOr sensors also showed a reduced run-in time of minutes versus hours for control sensors. NO evolution does increase protein nitration in tissue surrounding the sensor, which may be linked to the suppression of inflammation. This study further emphasizes the importance of NO as an electroactive species that can potentially interfere with glucose (peroxide) detection. The NOr sensor offers a viable option for in vivo glucose sensor development.
NASA Technical Reports Server (NTRS)
Baker, D. N.; Hoffman, R. (Technical Monitor)
2001-01-01
This final report provides a final report on a NASA sponsored project involving data reduction and scientific analysis related to the Comprehensive Energetic Particle Pitch Angle Distribution (CEPPAD) experiment of POLAR. Dr. D.N. Baker, the chief scientist, has focused primarily on the calibration of CEPPAD sensors and the interpretation of data from the sensors which has led to discoveries regarding storm-substorm relationships in the earth's magnetosphere. The report contains approximately 190 bibliographic references to the activities of Baker and others involved.
STS-114 Engine Cut-off Sensor Anomaly Technical Consultation Report
NASA Technical Reports Server (NTRS)
Wilson, Timmy R.; Kichak, Robert A.; Ungar, Eugene K.; Cherney, Robert; Rickman, Steve L.
2009-01-01
The NESC consultation team participated in real-time troubleshooting of the Main Propulsion System (MPS) Engine Cutoff (ECO) sensor system failures during STS-114 launch countdown. The team assisted with External Tank (ET) thermal and ECO Point Sensor Box (PSB) circuit analyses, and made real-time inputs to the Space Shuttle Program (SSP) problem resolution teams. Several long-term recommendations resulted. One recommendation was to conduct cryogenic tests of the ECO sensors to validate, or disprove, the theory that variations in circuit impedance due to cryogenic effects on swaged connections within the sensor were the root cause of STS-114 failures.
Evaluation of a total energy-rate sensor on a transport airplane
NASA Technical Reports Server (NTRS)
Ostroff, A. J.; Hueschen, R. M.; Hellbaum, R. F.; Belcastro, C. M.; Creedon, J. F.
1983-01-01
A sensor that measures the rate of change of total energy of an airplane with respect to the airstream has been evaluated. The sensor consists of two cylindrical probes located on the fuselage of a transport airplane, an in line acoustic filter, and a pressure sensing altitude rate transducer. Sections of this report include the sensor description and experimental configuration, frequency response tests, analytical model development, and flight test results for several airplane maneuvers. The results section includes time history comparisons between data generated by the total energy rate sensor and calculated data derived from independent sources.
NASA Astrophysics Data System (ADS)
Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing
2013-08-01
Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.
Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing
2013-01-01
Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring. PMID:23982222
Lu, Rui; Mizaikoff, Boris; Li, Wen-Wei; Qian, Chen; Katzir, Abraham; Raichlin, Yosef; Sheng, Guo-Ping; Yu, Han-Qing
2013-01-01
Chlorinated aliphatic hydrocarbons and chlorinated aromatic hydrocarbons (CHCs) are toxic and carcinogenic contaminants commonly found in environmental samples, and efficient online detection of these contaminants is still challenging at the present stage. Here, we report an advanced Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) sensor for in-situ and simultaneous detection of multiple CHCs, including monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, trichloroethylene, perchloroethylene, and chloroform. The polycrystalline silver halide sensor fiber had a unique integrated planar-cylindric geometry, and was coated with an ethylene/propylene copolymer membrane to act as a solid phase extractor, which greatly amplified the analytical signal and contributed to a higher detection sensitivity compared to the previously reported sensors. This system exhibited a high detection sensitivity towards the CHCs mixture at a wide concentration range of 5~700 ppb. The FTIR-ATR sensor described in this study has a high potential to be utilized as a trace-sensitive on-line device for water contamination monitoring.
Use of Occupancy Sensors in LED Parking Lot and Garage Applications: Early Experiences
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinzey, Bruce R.; Myer, Michael; Royer, Michael P.
2012-11-07
Occupancy sensor systems are gaining traction as an effective technological approach to reducing energy use in exterior commercial lighting applications. Done correctly, occupancy sensors can substantially enhance the savings from an already efficient lighting system. However, this technology is confronted by several potential challenges and pitfalls that can leave a significant amount of the prospective savings on the table. This report describes anecdotal experiences from field installations of occupancy sensor controlled light-emitting diode (LED) lighting at two parking structures and two parking lots. The relative levels of success at these installations reflect a marked range of potential outcomes: from anmore » additional 76% in energy savings to virtually no additional savings. Several issues that influenced savings were encountered in these early stage installations and are detailed in the report. Ultimately, care must be taken in the design, selection, and commissioning of a sensor-controlled lighting installation, else the only guaranteed result may be its cost.« less
Scalable Low-Cost Fabrication of Disposable Paper Sensors for DNA Detection
2015-01-01
Controlled integration of features that enhance the analytical performance of a sensor chip is a challenging task in the development of paper sensors. A critical issue in the fabrication of low-cost biosensor chips is the activation of the device surface in a reliable and controllable manner compatible with large-scale production. Here, we report stable, well-adherent, and repeatable site-selective deposition of bioreactive amine functionalities and biorepellant polyethylene glycol-like (PEG) functionalities on paper sensors by aerosol-assisted, atmospheric-pressure, plasma-enhanced chemical vapor deposition. This approach requires only 20 s of deposition time, compared to previous reports on cellulose functionalization, which takes hours. A detailed analysis of the near-edge X-ray absorption fine structure (NEXAFS) and its sensitivity to the local electronic structure of the carbon and nitrogen functionalities. σ*, π*, and Rydberg transitions in C and N K-edges are presented. Application of the plasma-processed paper sensors in DNA detection is also demonstrated. PMID:25423585
Detection of bacterial 16S rRNA using a molecular beacon-based X sensor
Gerasimova, Yulia V.; Kolpashchikov, Dmitry M.
2012-01-01
We demonstrate how a long structurally constrained RNA can be analyzed in homogeneous solution at ambient temperatures with high specificity using a sophisticated biosensor. The sensor consists of a molecular beacon probe as a signal reporter and two DNA adaptor strands, which have fragments complementary to the reporter and to the analyzed RNA. One adaptor strand uses its long RNA-binding arm to unwind the RNA secondary structure. Second adaptor strand with a short RNA-binding arm hybridizes only to a fully complementary site, thus providing high recognition specificity. Overall the three-component sensor and the target RNA form a four-stranded DNA crossover (X) structure. Using this sensor, E.coli 16S rRNA was detected in real time with the detection limit of ~ 0.17 nM. The high specificity of the analysis was proven by differentiating B.subtilus from E.coli 16S rRNA sequences. The sensor responds to the presence of the analyte within seconds. PMID:23021850
Yu, Gui-Feng; Yan, Xu; Yu, Miao; Jia, Meng-Yang; Pan, Wei; He, Xiao-Xiao; Han, Wen-Peng; Zhang, Zhi-Ming; Yu, Liang-Min; Long, Yun-Ze
2016-02-07
A facile fabrication strategy via electrospinning and followed by in situ polymerization to fabricate a patterned, highly stretchable, and conductive polyaniline/poly(vinylidene fluoride) (PANI/PVDF) nanofibrous membrane is reported. Owing to the patterned structure, the nanofibrous PANI/PVDF strain sensor can detect a strain up to 110%, for comparison, which is 2.6 times higher than the common nonwoven PANI/PVDF mat and much larger than the previously reported values (usually less than 15%). Meanwhile, the conductivity of the patterned strain sensor shows a linear response to the applied strain in a wide range from 0% to about 85%. Additionally, the patterned PANI/PVDF strain sensor can completely recover to its original electrical and mechanical values within a strain range of more than 22%, and exhibits good durability over 10,000 folding-unfolding tests. Furthermore, the strain sensor also can be used to detect finger motion. The results demonstrate promising application of the patterned nanofibrous membrane in flexible electronic fields.
Scalable Low-Cost Fabrication of Disposable Paper Sensors for DNA Detection
Gandhiraman, Ram P.; Nordlund, Dennis; Jayan, Vivek; ...
2014-11-25
Controlled integration of features that enhance the analytical performance of a sensor chip is a challenging task in the development of paper sensors. A critical issue in the fabrication of low-cost biosensor chips is the activation of the device surface in a reliable and controllable manner compatible with large-scale production. Here, we report stable, well-adherent, and repeatable site-selective deposition of bioreactive amine functionalities and biorepellant polyethylene glycol-like (PEG) functionalities on paper sensors by aerosol-assisted, atmospheric-pressure, plasma-enhanced chemical vapor deposition. This approach requires only 20 s of deposition time, compared to previous reports on cellulose functionalization, which takes hours. We presentmore » a detailed analysis of the near-edge X-ray absorption fine structure (NEXAFS) and its sensitivity to the local electronic structure of the carbon and nitrogen functionalities. σ*, π*, and Rydberg transitions in C and N K-edges. Lastly, application of the plasma-processed paper sensors in DNA detection is also demonstrated.« less
Managing piezoelectric sensor jitter: kinematic position tracking applications
NASA Astrophysics Data System (ADS)
Khomo, Malome T.
2016-02-01
Piezo-acoustic distance tracking sensors have challenges of reporting true distance readings. Challenges include directional anisotropy signal loss in transmission power and in receiver sensitivity, distance-related attenuation of signal and the phase shifts that result in jittery values, some preceding, and others succeeding the expected distance readings. There also exist signal time losses arising from dead time associated with processor latency, with carrier signal pulse length and with voltage rise-time delays in pulse detection. Together these factors cause distance under-reporting, and more critically, makes each reported value uncertain, which is unacceptable in distance-critical applications. Piezo-inertial accelerometers have equivalent if not more severe challenges in tri-axial configurations, for instance where a rotational tilt may happen under linear accelerative force. In the absence of tensor component adaptation to change of orientation, signal is lost until the next axial sensor detects it. Study paper focusses on piezo-acoustic transducers UCD1007 and 400SR160 (40kHz), used in a face-to-face configuration over a 600mm range. Within that range 10 successive phase shift wave fronts were identified, but it took 15 reconstructed wave fronts to uniquely identify a continuous end-to-end jitter-free and slippage-free kinematic data stream from the jittery sensor data. The additional 5 degrees of freedom were consumed by the 5-stage filter applied. The technique has remarkable combinatorial and projective geometry implications for digital sensor design. It is possible for the procedure to be applicable in 3-axis accelerometers and adapted into firmware for truly kinematic device driver interfaces so long as the reporting rates are matched with the user interface refresh rates. It is shown that acoustic transducer sensors require phase loop locking for kinematic continuity whereas gravimetric accelerometers demand better measurement time consistence in sensor values for induced kinematic phase locking.
Quarterly literature review of the remote sensing of natural resources
NASA Technical Reports Server (NTRS)
Fears, C. B. (Editor); Inglis, M. H. (Editor)
1977-01-01
The Technology Application Center reviewed abstracted literature sources, and selected document data and data gathering techniques which were performed or obtained remotely from space, aircraft or groundbased stations. All of the documentation was related to remote sensing sensors or the remote sensing of the natural resources. Sensors were primarily those operating within the 10 to the minus 8 power to 1 meter wavelength band. Included are NASA Tech Briefs, ARAC Industrial Applications Reports, U.S. Navy Technical Reports, U.S. Patent reports, and other technical articles and reports.
Design of Inkjet-Printed RFID-Based Sensor on Paper: Single- and Dual-Tag Sensor Topologies.
Kim, Sangkil; Georgiadis, Apostolos; Tentzeris, Manos M
2018-06-17
The detailed design considerations for the printed RFID-based sensor system is presented in this paper. Starting from material selection and metallization method, this paper discusses types of RFID-based sensors (single- & dual-tag sensor topologies), design procedures, and performance evaluation methods for the wireless sensor system. The electrical properties of the paper substrates (cellulose-based and synthetic papers) and the silver nano-particle-based conductive film are thoroughly characterized for RF applications up to 8 GHz. The reported technology could potentially set the foundation for truly “green”, low-cost, scalable wireless topologies for autonomous Internet-of-Things (IoT), bio-monitoring, and “smart skin” applications.
Ong, Keat G.; Paulose, Maggie; Grimes, Craig A.
2003-01-01
A wireless, passive, remote-query sensor for monitoring sodium hypochlorite (bleach) solutions is reported. The sensor is comprised of a magnetically-soft ferromagnetic ribbon, coated with a layer of polyurethane and alumina, having a large and nonlinear permeability that supports higher-order harmonics in response to a time varying magnetic field. The hypochlorite ions induce swelling in the coating, with the resultant stress altering the harmonic signature of the sensor from which the sodium hypochlorite concentration can be determined. The wireless, passive nature of the sensor platform enables long-term monitoring of bleach concentrations in the environment. The sensor platform can be extended to other chemical analytes of interest as desired.
Engineering New Aptamer Geometries for Electrochemical Aptamer-Based Sensors
White, Ryan J.; Plaxco, Kevin W.
2010-01-01
Electrochemical aptamer-based sensors (E-AB sensors) represent a promising new approach to the detection of small molecules. E-AB sensors comprise an aptamer that is attached at one end to an electrode surface. The distal end of the aptamer probed is modified with an electroactive redox marker for signal transduction. Herein we report on the optimization of a cocaine-detecting E-AB sensor via optimization of the geometry of the aptamer. We explore two new aptamer architectures, one in which we concatenate three cocaine aptamers into a poly-aptamer and a second in which we divide the cocaine aptamer into pieces connected via an unstructured, 60-thymine linker. Both of these structures are designed such that the reporting redox tag will be located farther from the electrode in the unfolded, target-free conformation. Consistent with this, we find that signal gains of these two constructs are two to three times higher than that of the original E-AB architecture. Likewise all three architectures are selective enough to deploy directly in complex sample matrices, such as undiluted whole blood, with all three sensors successfully detecting the presence of cocaine. The findings in this ongoing study should be of value in future efforts to optimize the signaling of electrochemical aptamer-based sensors. PMID:20436792
Wu, Liqian; Zhang, Lichun; Sun, Mingxia; Liu, Rui; Yu, Lingzhu; Lv, Yi
2017-12-19
Cataluminescence- (CTL-) based sensors are among the most attractive and effective tools for gas sensing, owing to their efficient selectivity, high sensitivity, and rapidity. As the sensing materials of CTL-based sensors, metal-based catalysts easily bring about high costs and environmental pollution of heavy metals. More importantly, the long-term stability of metal-based catalysts is usually rather poor. Metal-free catalysts have unique advantages such as environmental friendliness, low costs, and long-term stability, making them promising materials for CTL-based sensors. Herein, we report the fabrication of a CTL sensor based on a metal-free catalyst. F-doped cage-like SiC was synthesized by wet chemical etching. The as-prepared products showed a rapid, stable, highly selective, and sensitive cataluminescent response to H 2 S. The stability of the sensor was demonstrated to be fairly good for at least 15 days. After CTL tests, F-doped cage-like SiC retained its original morphology, structure, and chemical composition. In addition, to the best of our knowledge, this is the first report of a metal-free CTL sensor. Metal-free catalysts are environmentally friendly and low in cost and exhibit long-term stability, which could open a new avenue of CTL sensing.
Tadakaluru, Sreenivasulu; Thongsuwan, Wiradej; Singjai, Pisith
2014-01-06
Conventional metallic strain sensors are flexible, but they can sustain maximum strains of only ~5%, so there is a need for sensors that can bear high strains for multifunctional applications. In this study, we report stretchable and flexible high-strain sensors that consist of entangled and randomly distributed multiwall carbon nanotubes or graphite flakes on a natural rubber substrate. Carbon nanotubes/graphite flakes were sandwiched in natural rubber to produce these high-strain sensors. Using field emission scanning electron microscopy, the morphology of the films for both the carbon nanotube and graphite sensors were assessed under different strain conditions (0% and 400% strain). As the strain was increased, the films fractured, resulting in an increase in the electrical resistance of the sensor; this change was reversible. Strains of up to 246% (graphite sensor) and 620% (carbon nanotube sensor) were measured; these values are respectively ~50 and ~120 times greater than those of conventional metallic strain sensors.
EDGE COMPUTING AND CONTEXTUAL INFORMATION FOR THE INTERNET OF THINGS SENSORS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Levente
Interpreting sensor data require knowledge about sensor placement and the surrounding environment. For a single sensor measurement, it is easy to document the context by visual observation, however for millions of sensors reporting data back to a server, the contextual information needs to be automatically extracted from either data analysis or leveraging complimentary data sources. Data layers that overlap spatially or temporally with sensor locations, can be used to extract the context and to validate the measurement. To minimize the amount of data transmitted through the internet, while preserving signal information content, two methods are explored; computation at the edgemore » and compressed sensing. We validate the above methods on wind and chemical sensor data (1) eliminate redundant measurement from wind sensors and (2) extract peak value of a chemical sensor measuring a methane plume. We present a general cloud based framework to validate sensor data based on statistical and physical modeling and contextual data extracted from geospatial data.« less
Teich, Sorin; Al-Rawi, Wisam; Heima, Masahiro; Faddoul, Fady F; Goldzweig, Gil; Gutmacher, Zvi; Aizenbud, Dror
2016-10-01
To evaluate the image quality generated by eight commercially available intraoral sensors. Eighteen clinicians ranked the quality of a bitewing acquired from one subject using eight different intraoral sensors. Analytical methods used to evaluate clinical image quality included the Visual Grading Characteristics method, which helps to quantify subjective opinions to make them suitable for analysis. The Dexis sensor was ranked significantly better than Sirona and Carestream-Kodak sensors; and the image captured using the Carestream-Kodak sensor was ranked significantly worse than those captured using Dexis, Schick and Cyber Medical Imaging sensors. The Image Works sensor image was rated the lowest by all clinicians. Other comparisons resulted in non-significant results. None of the sensors was considered to generate images of significantly better quality than the other sensors tested. Further research should be directed towards determining the clinical significance of the differences in image quality reported in this study. © 2016 FDI World Dental Federation.
Tadakaluru, Sreenivasulu; Thongsuwan, Wiradej; Singjai, Pisith
2014-01-01
Conventional metallic strain sensors are flexible, but they can sustain maximum strains of only ∼5%, so there is a need for sensors that can bear high strains for multifunctional applications. In this study, we report stretchable and flexible high-strain sensors that consist of entangled and randomly distributed multiwall carbon nanotubes or graphite flakes on a natural rubber substrate. Carbon nanotubes/graphite flakes were sandwiched in natural rubber to produce these high-strain sensors. Using field emission scanning electron microscopy, the morphology of the films for both the carbon nanotube and graphite sensors were assessed under different strain conditions (0% and 400% strain). As the strain was increased, the films fractured, resulting in an increase in the electrical resistance of the sensor; this change was reversible. Strains of up to 246% (graphite sensor) and 620% (carbon nanotube sensor) were measured; these values are respectively ∼50 and ∼120 times greater than those of conventional metallic strain sensors. PMID:24399158
Assessment of Rifle Marksmanship Skill Using Sensor-Based Measures. CRESST Report 755
ERIC Educational Resources Information Center
Nagashima, Sam O.; Chung, Gregory K. W. K.; Espinosa, Paul D.; Berka, Chris; Baker, Eva L.
2009-01-01
The goal of this report was to test the use of sensor-based skill measures in evaluating performance differences in rifle marksmanship. Ten shots were collected from 30 novices and 9 experts. Three measures for breath control and one for trigger control were used to predict skill classification. The data were fitted with a logistic regression…
Application of ion-sensitive sensors in water quality monitoring.
Winkler, S; Rieger, L; Saracevic, E; Pressl, A; Gruber, G
2004-01-01
Within the last years a trend towards in-situ monitoring can be observed, i.e. most new sensors for water quality monitoring are designed for direct installation in the medium, compact in size and use measurement principles which minimise maintenance demand. Ion-sensitive sensors (Ion-Sensitive-Electrode--ISE) are based on a well known measurement principle and recently some manufacturers have released probe types which are specially adapted for application in water quality monitoring. The function principle of ISE-sensors, their advantages, limitations and the different methods for sensor calibration are described. Experiences with ISE-sensors from applications in sewer networks, at different sampling points within wastewater treatment plants and for surface water monitoring are reported. An estimation of investment and operation costs in comparison to other sensor types is given.
2011-03-09
anu.edu.au Nocturnal visual orientation in flying insects: a benchmark for the design of vision-based sensors in Micro-Aerial Vehicles Report...9 10 Technical horizon sensors Over the past few years, a remarkable proliferation of designs for micro-aerial vehicles (MAVs) has occurred...possible elevations, it may severely degrade the performance of sensors by local saturation. Therefore it is necessary to find a method whereby the effect
Resonating periodic waveguides as ultraresolution sensors in biomedicine
NASA Astrophysics Data System (ADS)
Wawro, Debra D.; Priambodo, Purnomo; Magnusson, Robert
2004-10-01
Optical sensor technology based on subwavelength periodic waveguides is applied for tag-free, high-resolution biomedical and chemical detection. Measured resonance wavelength shifts of 6.4 nm for chemically attached Bovine Serum Albumin agree well with theory for a sensor tested in air. Reflection peak efficiencies of 90% are measured, and do not degrade upon biolayer attachment. Phase detection methods are investigated to enhance sensor sensitivity and resolution. Direct measurement of the resonant phase response is reported for the first time using ellipsometric measurement techniques.
Hazard detection and avoidance sensor for NASA's planetary landers
NASA Technical Reports Server (NTRS)
Lau, Brian; Chao, Tien-Hsin
1992-01-01
An optical terrain analysis based sensor system specifically designed for landing hazard detection as required for NASA's autonomous planetary landers is introduced. This optical hazard detection and avoidance (HDA) sensor utilizes an optoelectronic wedge-and-ting (WRD) filter for Fourier transformed feature extraction and an electronic neural network processor for pattern classification. A fully implemented optical HDA sensor would assure safe landing of the planetary landers. Computer simulation results of a successful feasibility study is reported. Future research for hardware system implementation is also provided.
Current and emerging laser sensors for greenhouse gas sensing and leak detection
NASA Astrophysics Data System (ADS)
Frish, Michael B.
2014-05-01
To reduce atmospheric accumulation of the greenhouse gases methane and carbon dioxide, networks of continuously operating sensors that monitor and map their sources are desirable. In this paper, we discuss advances in laser-based open-path leak detectors, as well as technical and economic challenges inhibiting widespread sensor deployment for "ubiquitous monitoring". We describe permanently-installed, wireless, solar-powered sensors that overcome previous installation and maintenance difficulties while providing autonomous real-time leak reporting without false alarms.
Design and laboratory testing of a prototype linear temperature sensor
NASA Astrophysics Data System (ADS)
Dube, C. M.; Nielsen, C. M.
1982-07-01
This report discusses the basic theory, design, and laboratory testing of a prototype linear temperature sensor (or "line sensor'), which is an instrument for measuring internal waves in the ocean. The operating principle of the line sensor consists of measuring the average resistance change of a vertically suspended wire (or coil of wire) induced by the passage of an internal wave in a thermocline. The advantage of the line sensor over conventional internal wave measurement techniques is that it is insensitive to thermal finestructure which contaminates point sensor measurements, and its output is approximately linearly proportional to the internal wave displacement. An approximately one-half scale prototype line sensor module was teste in the laboratory. The line sensor signal was linearly related to the actual fluid displacement to within 10%. Furthermore, the absolute output was well predicted (within 25%) from the theoretical model and the sensor material properties alone. Comparisons of the line sensor and a point sensor in a wavefield with superimposed turbulence (finestructure) revealed negligible distortion in the line sensor signal, while the point sensor signal was swamped by "turbulent noise'. The effects of internal wave strain were also found to be negligible.
Automated pedestrian counter : final report, February 2010.
DOT National Transportation Integrated Search
2010-02-01
Emerging sensor technologies accelerated the shift toward automatic pedestrian counting methods to : acquire reliable long-term data for transportation design, planning, and safety studies. Although a : number of commercial pedestrian sensors are ava...
Croce, Robert A; Vaddiraju, Santhisagar; Papadimitrakopoulos, Fotios; Jain, Faquir C
2012-10-01
The performance of implantable electrochemical glucose sensors is highly dependent on the flux-limiting (glucose, H(2)O(2), O(2)) properties of their outer membranes. A careful understanding of the diffusion profiles of the participating species throughout the sensor architecture (enzyme and membrane layer) plays a crucial role in designing a robust sensor for both in vitro and in vivo operation. This paper reports the results from the mathematical modeling of Clark's first generation amperometric glucose sensor coated with layer-by-layer assembled outer membranes in order to obtain and compare the diffusion profiles of various participating species and their effect on sensor performance. Devices coated with highly glucose permeable (HAs/Fe(3+)) membranes were compared with devices coated with PSS/PDDA membranes, which have an order of magnitude lower permeability. The simulation showed that the low glucose permeable membrane (PSS/PDDA) sensors exhibited a 27% higher amperometric response than the high glucose permeable (HAs/Fe(3+)) sensors. Upon closer inspection of H(2)O(2)diffusion profiles, this non-typical higher response from PSS/PDDA is not due to either a larger glucose flux or comparatively larger O(2) concentrations within the sensor geometry, but rather is attributed to a 48% higher H(2)O(2) concentration in the glucose oxidase enzyme layer of PSS/PDDA coated sensors as compared to HAs/Fe(3+) coated ones. These simulated results corroborate our experimental findings reported previously. The high concentration of H(2)O(2) in the PSS/PDDA coated sensors is due to the low permeability of H(2)O(2) through the PSS/PDDA membrane, which also led to an undesired increase in sensor response time. Additionally, it was found that this phenomenon occurs for all enzyme thicknesses investigated (15, 20 and 25 nm), signifying the need for a holistic approach in designing outer membranes for amperometric biosensors.
TPS In-Flight Health Monitoring Project Progress Report
NASA Technical Reports Server (NTRS)
Kostyk, Chris; Richards, Lance; Hudston, Larry; Prosser, William
2007-01-01
Progress in the development of new thermal protection systems (TPS) is reported. New approaches use embedded lightweight, sensitive, fiber optic strain and temperature sensors within the TPS. Goals of the program are to develop and demonstrate a prototype TPS health monitoring system, develop a thermal-based damage detection algorithm, characterize limits of sensor/system performance, and develop ea methodology transferable to new designs of TPS health monitoring systems. Tasks completed during the project helped establish confidence in understanding of both test setup and the model and validated system/sensor performance in a simple TPS structure. Other progress included complete initial system testing, commencement of the algorithm development effort, generation of a damaged thermal response characteristics database, initial development of a test plan for integration testing of proven FBG sensors in simple TPS structure, and development of partnerships to apply the technology.
Ahn, Heesang; Song, Hyerin; Kim, Kyujung
2017-01-01
From active developments and applications of various devices to acquire outside and inside information and to operate based on feedback from that information, the sensor market is growing rapidly. In accordance to this trend, the surface plasmon resonance (SPR) sensor, an optical sensor, has been actively developed for high-sensitivity real-time detection. In this study, the fundamentals of SPR sensors and recent approaches for enhancing sensing performance are reported. In the section on the fundamentals of SPR sensors, a brief description of surface plasmon phenomena, SPR, SPR-based sensing applications, and several configuration types of SPR sensors are introduced. In addition, advanced nanotechnology- and nanofabrication-based techniques for improving the sensing performance of SPR sensors are proposed: (1) localized SPR (LSPR) using nanostructures or nanoparticles; (2) long-range SPR (LRSPR); and (3) double-metal-layer SPR sensors for additional performance improvements. Consequently, a high-sensitivity, high-biocompatibility SPR sensor method is suggested. Moreover, we briefly describe issues (miniaturization and communication technology integration) for future SPR sensors. PMID:29301238
Polymer-based sensor array for phytochemical detection
NASA Astrophysics Data System (ADS)
Weerakoon, Kanchana A.; Hiremath, Nitilaksha; Chin, Bryan A.
2012-05-01
Monitoring for the appearance of volatile organic compounds emitted by plants which correspond to time of first insect attack can be used to detect the early stages of insect infestation. This paper reports a chemical sensor array consisting of polymer based chemiresistor sensors that could detect insect infestation effectively. The sensor array consists of sensors with micro electronically fabricated interdigitated electrodes, and twelve different types of electro active polymer layers. The sensor array was cheap, easy to fabricate, and could be used easily in agricultural fields. The polymer array was found to be sensitive to a variety of volatile organic compounds emitted by plants including γ-terpinene α-pinene, pcymene, farnesene, limonene and cis-hexenyl acetate. The sensor array was not only able to detect but also distinguish between these compounds. The twelve sensors produced a resistance change for each of the analytes detected, and each of these responses together produced a unique fingerprint, enabling to distinguish among these chemicals.
Development of advanced high-temperature heat flux sensors. Phase 2: Verification testing
NASA Technical Reports Server (NTRS)
Atkinson, W. H.; Cyr, M. A.; Strange, R. R.
1985-01-01
A two-phase program is conducted to develop heat flux sensors capable of making heat flux measurements throughout the hot section of gas turbine engines. In Phase 1, three types of heat flux sensors are selected; embedded thermocouple, laminated, and Gardon gauge sensors. A demonstration of the ability of these sensors to operate in an actual engine environment is reported. A segmented liner of each of two combustors being used in the Broad Specification Fuels Combustor program is instrumented with the three types of heat flux sensors then tested in a high pressure combustor rig. Radiometer probes are also used to measure the radiant heat loads to more fully characterize the combustor environment. Test results show the heat flux sensors to be in good agreement with radiometer probes and the predicted data trends. In general, heat flux sensors have strong potential for use in combustor development programs.
Technical Operations (TOPS) IV Task Order 0003: Responsive Interface for Transport Tuning (RITT)
2016-05-29
on the further development of artificial hair sensors (AHS) featuring a responsive carbon nanotube (CNT) array to serve as a piezoresistive element...under separate cover, as AFRL Interim Report AFRL-RX-WP-TR-2016-0071 dated 30 October 2015. 15. SUBJECT TERMS artificial hair sensor, carbon... Hair Sensors: Fabrication and Model Parameterization .......................... 4 3.1.1 Introduction
2002-09-30
onr.navy.mil Mr. Wallace Harrison, GIFTS Program Manager NASA EO-3, New Millenium Program, Langley Research Center phone: 757-864-6680 fax: 757-864...Observing 3 Geostationary Imaging Fourier Transform Spectrometer ( GIFTS ) sensor development to provide this advanced capability. The IOMI program will...share costs for the GIFTS sensor development, the spacecraft bus, provide lifetime enhancements to the GIFTS sensor, and 1 Report Documentation Page
Calibration Of Partial-Pressure-Of-Oxygen Sensors
NASA Technical Reports Server (NTRS)
Yount, David W.; Heronimus, Kevin
1995-01-01
Report and analysis of, and discussion of improvements in, procedure for calibrating partial-pressure-of-oxygen sensors to satisfy Spacelab calibration requirements released. Sensors exhibit fast drift, which results in short calibration period not suitable for Spacelab. By assessing complete process of determining total drift range available, calibration procedure modified to eliminate errors and still satisfy requirements without compromising integrity of system.
Detection of Avian Influenza Virus from Cloacal Swabs Using a Disposable Well Gate FET Sensor.
Park, Sungwook; Choi, Jaebin; Jeun, Minhong; Kim, Yongdeok; Yuk, Seong-Su; Kim, Sang Kyung; Song, Chang-Seon; Lee, Seok; Lee, Kwan Hyi
2017-07-01
Current methods to detect avian influenza viruses (AIV) are time consuming and lo inw sensitivity, necessitating a faster and more sensitive sensor for on-site epidemic detection in poultry farms and urban population centers. This study reports a field effect transistor (FET) based AIV sensor that detects nucleoproteins (NP) within 30 minutes, down to an LOD of 10 3 EID 50 mL -1 from a live animal cloacal swab. Previously reported FET sensors for AIV detection have not targeted NPs, an internal protein shared across multiple strains, due to the difficulty of field-effect sensing in a highly ionic lysis buffer. The AIV sensor overcomes the sensitivity limit with an FET-based platform enhanced with a disposable well gate (DWG) that is readily replaceable after each measurement. In a single procedure, the virus-containing sample is immersed in a lysis buffer mixture to expose NPs to the DWG surface. In comparison with commercial AIV rapid kits, the AIV sensor is proved to be highly sensitive, fast, and compact, proving its potential effectiveness as a portable biosensor. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A Passive and Wireless Sensor for Bone Plate Strain Monitoring.
Tan, Yisong; Hu, Jiale; Ren, Limin; Zhu, Jianhua; Yang, Jiaqi; Liu, Di
2017-11-16
This paper reports on a sensor for monitoring bone plate strain in real time. The detected bone plate strain could be used for judging the healing state of fractures in patients. The sensor consists of a magnetoelastic material, which can be wirelessly connected and passively embedded. In order to verify the effectiveness of the sensor, a tibia-bone plate-screw (TBS) model was established using the finite element analysis method. A variation of the bone plate strain was obtained via this model. A goat hindquarter tibia was selected as the bone fracture model in the experiment. The tibia was fixed on a high precision load platform and an external force was applied. Bone plate strain variation during the bone fracture healing process was acquired with sensing coils. Simulation results indicated that bone plate strain decreases as the bone gradually heals, which is consistent with the finite element analysis results. This validated the soundness of the sensor reported here. This sensor has wireless connections, no in vivo battery requirement, and long-term embedding. These results can be used not only for clinical practices of bone fracture healing, but also for bone fracture treatment and rehabilitation equipment design.
A molecular rotor based ratiometric sensor for basic amino acids
NASA Astrophysics Data System (ADS)
Pettiwala, Aafrin M.; Singh, Prabhat K.
2018-01-01
The inevitable importance of basic amino acids, arginine and lysine, in human health and metabolism demands construction of efficient sensor systems for them. However, there are only limited reports on the 'ratiometric' detection of basic amino acids which is further restricted by the use of chemically complex sensor molecules, which impedes their prospect for practical applications. Herein, we report a ratiometric sensor system build on simple mechanism of disassociation of novel emissive Thioflavin-T H-aggregates from heparin surface, when subjected to interaction with basic amino acids. The strong and selective electrostatic and hydrogen bonding interaction of basic amino acids with heparin leads to large alteration in photophysical attributes of heparin bound Thioflavin-T, which forms a highly sensitive sensor platform for detection of basic amino acids in aqueous solution. These selective interactions between basic amino acids and heparin allow our sensor system to discriminate arginine and lysine from other amino acids. This unique mechanism of dissociation of Thioflavin-T aggregates from heparin surface provides ratiometric response on both fluorimetric and colorimetric outputs for detection of arginine and lysine, and thus it holds a significant advantage over other developed sensor systems which are restricted to single wavelength detection. Apart from the sensitivity and selectivity, our system also provides the advantage of simplicity, dual mode of sensing, and more importantly, it employs an inexpensive commercially available probe molecule, which is a significant advantage over other developed sensor systems that uses tedious synthesis protocol for the employed probe in the detection scheme, an impediment for practical applications. Additionally, our sensor system also shows response in complex biological media of serum samples.
A wall shear stress sensor using a pair of sidewall doped cantilevers
NASA Astrophysics Data System (ADS)
Nguyen, Thanh-Vinh; Kazama, Ryohei; Takahashi, Hidetoshi; Takahata, Tomoyuki; Matsumoto, Kiyoshi; Shimoyama, Isao
2017-07-01
In this paper, we report on a micro-electro mechanical system (MEMS)-based piezoresistive sensor for measuring shear stress induced by an airflow. The advantages of the proposed sensor include a simple sensing method and a high resonance frequency due to the small size of the sensing elements. Our sensor consists of a pair of 3 µm thick cantilevers with piezoresistors formed on the sidewall of their hinges to detect lateral deformation in the cantilevers induced by an airflow. Each cantilever has a 200 µm × 400 µm plate supported by two 150 µm long, 4 µm wide beams. The piezoresistors on the two cantilevers are designed to deform in opposite manners when a shear stress is applied and in the same manner when a pressure is applied. Therefore, the applied shear stress can be detected from the difference in the responses of the two cantilevers without becoming conflated with pressure. In this paper, the design, fabrication and evaluation of the proposed sensor are reported and compared to numerical simulation results. From the experimental results, the resolution of the sensor and its first resonance frequency are 1.3 Pa and 3.9 kHz, respectively. Moreover, we show that the effect of temperature on the readout of the sensor can be eliminated using a temperature-compensating piezoresistor fabricated on the same sensor chip. Finally, using the fabricated sensor, the measurement of the shear stress induced by an airflow with velocity between -10 and 10 m s-1 is demonstrated.
Microgravity Investigation of Crew Reactions in 0-G (MICR0-G): Ground-Based Development Effort
NASA Technical Reports Server (NTRS)
Newman, Dava J.
2002-01-01
This report describes the technology development of an advanced load sensor ground-based prototype and details the preliminary tests in microgravity during parabolic flights. The research effort is entitled, the Microgravity Investigation and Crew Reactions in 0-G (MICR0-G), a ground-based research effort funded by the National Aeronautics and Space Administration (NASA). The MICR0-G project was a follow-on to the Enhanced Dynamic Load Sensors (EDLS) spaceflight experiment flown on the Russian Space Station Mir. The technology development of the advanced load sensor prototype has been carried out by the Massachusetts Institute of Technology (MIT), with collaboration from Politecnico di Milano University and the Italian Space Agency (ASI). The key hardware of the advanced sensor prototype is a set of two types of load sensors - a hand-hold and foot restraints - similar in appearance to the mobility aids found in the Space Shuttle orbiter to assist the crew in moving inside the spacecraft, but able to measure the applied forces and moments about the x-, y-, and z- axes. The aim of Chapter 1 is to give a brief overview of the report contents. The first section summarizes the previous research efforts on astronaut-induced loads in microgravity. The second section provides information on the MICR0-G research project and the technology development work conducted at MIT. Section 1.3 details the motivation for designing a new generation of load sensors and describes the main enhancements and contributions of the MICR0-G advanced load sensors system compared to the EDLS system. Finally, the last section presents the outline of the report.
Dunton, Genevieve Fridlund; Dzubur, Eldin; Kawabata, Keito; Yanez, Brenda; Bo, Bin; Intille, Stephen
2014-01-01
Despite the known advantages of objective physical activity monitors (e.g., accelerometers), these devices have high rates of non-wear, which leads to missing data. Objective activity monitors are also unable to capture valuable contextual information about behavior. Adolescents recruited into physical activity surveillance and intervention studies will increasingly have smartphones, which are miniature computers with built-in motion sensors. This paper describes the design and development of a smartphone application ("app") called Mobile Teen that combines objective and self-report assessment strategies through (1) sensor-informed context-sensitive ecological momentary assessment (CS-EMA) and (2) sensor-assisted end-of-day recall. The Mobile Teen app uses the mobile phone's built-in motion sensor to automatically detect likely bouts of phone non-wear, sedentary behavior, and physical activity. The app then uses transitions between these inferred states to trigger CS-EMA self-report surveys measuring the type, purpose, and context of activity in real-time. The end of the day recall component of the Mobile Teen app allows users to interactively review and label their own physical activity data each evening using visual cues from automatically detected major activity transitions from the phone's built-in motion sensors. Major activity transitions are identified by the app, which cues the user to label that "chunk," or period, of time using activity categories. Sensor-driven CS-EMA and end-of-day recall smartphone apps can be used to augment physical activity data collected by objective activity monitors, filling in gaps during non-wear bouts and providing additional real-time data on environmental, social, and emotional correlates of behavior. Smartphone apps such as these have potential for affordable deployment in large-scale epidemiological and intervention studies.
Dunton, Genevieve Fridlund; Dzubur, Eldin; Kawabata, Keito; Yanez, Brenda; Bo, Bin; Intille, Stephen
2013-01-01
Introduction: Despite the known advantages of objective physical activity monitors (e.g., accelerometers), these devices have high rates of non-wear, which leads to missing data. Objective activity monitors are also unable to capture valuable contextual information about behavior. Adolescents recruited into physical activity surveillance and intervention studies will increasingly have smartphones, which are miniature computers with built-in motion sensors. Methods: This paper describes the design and development of a smartphone application (“app”) called Mobile Teen that combines objective and self-report assessment strategies through (1) sensor-informed context-sensitive ecological momentary assessment (CS-EMA) and (2) sensor-assisted end-of-day recall. Results: The Mobile Teen app uses the mobile phone’s built-in motion sensor to automatically detect likely bouts of phone non-wear, sedentary behavior, and physical activity. The app then uses transitions between these inferred states to trigger CS-EMA self-report surveys measuring the type, purpose, and context of activity in real-time. The end of the day recall component of the Mobile Teen app allows users to interactively review and label their own physical activity data each evening using visual cues from automatically detected major activity transitions from the phone’s built-in motion sensors. Major activity transitions are identified by the app, which cues the user to label that “chunk,” or period, of time using activity categories. Conclusion: Sensor-driven CS-EMA and end-of-day recall smartphone apps can be used to augment physical activity data collected by objective activity monitors, filling in gaps during non-wear bouts and providing additional real-time data on environmental, social, and emotional correlates of behavior. Smartphone apps such as these have potential for affordable deployment in large-scale epidemiological and intervention studies. PMID:24616888
Thermal Evaluation of Fiber Bragg Gratings at Extreme Temperatures
NASA Technical Reports Server (NTRS)
Juergens, Jeffrey; Adamovsky, Grigory; Bhatt, Ramakrishna; Morscher, Gregory; Floyd, Bertram
2005-01-01
The development of integrated fiber optic sensors for use in aerospace health monitoring systems demands that the sensors be able to perform in extreme environments. In order to use fiber optic sensors effectively in an extreme environment one must have a thorough understanding of the sensor's capabilities, limitations, and performance under extreme environmental conditions. This paper reports on our current sensor evaluation examining the performance of freestanding fiber Bragg gratings (FBG) at extreme temperatures. While the ability of FBGs to survive at extreme temperatures has been established, their performance and long term survivability is not well documented. At extreme temperatures the grating structure would be expected to dissipate, degrading the sensors performance and eventually ceasing to return a detectable signal. The fiber jacket will dissipate leaving a brittle, unprotected fiber. For FBGs to be used in aerospace systems their performance and limitations need to be thoroughly understood at extreme temperatures. As the limits of the FBGs performance are pushed the long term survivability and performance of the sensor comes into question. We will not only examine the ability of FBGs to survive extreme temperatures but also look at their performance during many thermal cycles. This paper reports on test results of the performance of thermal cycling commercially available FBGs, at temperatures up to 1000 C, seen in aerospace applications. Additionally this paper will report on the performance of commercially available FBGs held at 1000 C for hundreds of hours. Throughout the evaluation process, various parameters of the FBGs performance were monitored and recorded. Several test samples were subjected to identical test conditions to allow for statistical analysis of the data. Test procedures, calibrations, referencing techniques, performance data, and interpretations and explanations of results are presented in the paper along with directions for future research.
Research on the conductivity of a haptic sensor, especially with the sensor under extended condition
NASA Astrophysics Data System (ADS)
Zheng, Yaoyang; Shimada, Kunio
2008-11-01
The present paper describes the application of magnetic compound fluid (MCF) rubber as a haptic sensor for use as a material for robot sensors, artificial skin, and so on. MCF rubber is one of several new composite materials utilizing the MCF magnetic responsive fluid developed by Shimada. By applying MCF to silicon oil rubber, we can make MCF rubber highly sensitive to temperature and electric conduction. By mixing Cu and Ni particles in the silicon oil rubber and then applying a strong magnetic field, we can produce magnetic clusters at high density. The clusters form a network, as confirmed by optical observation. The MCF rubber with small deformations can act as an effective sensor. We report herein several experiments in which changes in the MCF rubber's resistance were observed when the rubber was compressed and a deformation was generated. We then made a trial haptic sensor using the MCF conductive rubber and performed many experiments to observe changes in the electrical resistance of the sensor. The experimental results showed that the proposed sensor made with MCF conductive rubber is useful for sensing small amounts of pressure or small deformations. Sometimes, however, the sensor rubber will be extended when we apply this sensor to the finger of the robot or an elbow. In these cases, it is necessary to understand the changes in sensor's conductivity. We therefore carried out some experiments to demonstrate how, under tensile conditions, the sensor's conductivity changes to a small value easier than the sensor in free condition. The results show that the sensors became more sensitive to the same pressure under extended conditions. In the present paper, we first describe the new type of functional fluid MCF rubber and a new composite material based on this MCF fluid. We then explain the production method for MCF conductive rubber and its conductive algorithm. Finally, we report our results regarding the MCF sensitivity when the MCF rubber was pulled. These experiments show an improvement in the sensitivity of the MCF rubber in the extended state.
Forward-looking automotive radar sensor
NASA Astrophysics Data System (ADS)
Ganci, Paul; Potts, Steven; Okurowski, Frank
1995-12-01
For intelligent cruise control (ICC) and forward looking collision warning systems to be successful products they must provide robust performance in a complex roadway environment. Inconveniences caused by dropped tracks and nuisance alarms will not be tolerated by consumers, and would likely result in rejection of these new technologies in the marketplace. The authors report on a low-cost automotive millimeter wave (MMW) radar design which addresses shortcomings associated with previously reported ICC system implementations. The importance of the sensor's ability to identify and separately track all obstacles in the field of view is discussed. The applicability of the MMW's FM-CW sensor implementation to collision warning systems is also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, Hai; Dong, Junhang; Lin, Jerry
2012-03-01
This is a final technical report for the first project year from July 1, 2005 to Jan 31, 2012 for DoE/NETL funded project DE-FC26-05NT42439: Development of Nanocrystalline Doped-Ceramic Enabled Fiber Sensors for High Temperature In-Situ Monitoring of Fossil Fuel Gases. This report summarizes the technical progresses and achievements towards the development of novel nanocrystalline doped ceramic material-enabled optical fiber sensors for in situ and real time monitoring the gas composition of flue or hot gas streams involved in fossil-fuel based power generation and hydrogen production.
Limited Scope Design Study for Multi-Sensor Towbody
2016-06-01
FINAL REPORT Limited Scope Design Study for Multi-Sensor Towbody SERDP Project MR-2501 JUNE 2016 Dr. Kevin Williams Tim McGinnis...prepared under contract to the Department of Defense Strategic Environmental Research and Development Program (SERDP). The publication of this...Left Blank REPORT DOCUMENTATION PAGE Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 Form Approved OMB No. 0704-0188 The public
Contract-Based Integration of Cyber-Physical Analyses
2014-10-14
for cyber-physical systems , 2013 [3] Torngren et al. Integrating viewpoints in the development of mechatronic products, 2013 [4] Rajhans et al...Conference on Embedded Software Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is...failures 5 Analytic aspect of integration Sensor Sampling PID Controller Actuator Controller Communication bus Sensor board CPU Actuator board System Bin
2.45 GHz Rectenna Designed for Wireless Sensors Operating at 500 C
NASA Technical Reports Server (NTRS)
Ponchak, George E.; Schwartz, Zachary D.; Jordan, Jennifer L.; Downey, Alan N.; Neudeck, Philip G.
2004-01-01
High temperature wireless sensors that operate at 500 C are required for aircraft engine monitoring and performance improvement These sensors would replace currently used hard-wired sensors and lead to a substantial reduction in mass. However, even if the sensor output data is transmitted wirelessly to a receiver in the cooler part of the engine, and the associated cables are eliminated, DC power cables are still required to operate the sensors and power the wireless circuits. To solve this problem, NASA is developing a rectenna, a circuit that receives RF power and converts it to DC power. The rectenna would be integrated with the wireless sensor, and the RF transmitter that powers the rectenna would be located in the cooler part of the engine. In this way, no cables to or from the sensors are required. Rectennas haw been demonstrated at ambient room temperature, but to date, no high temperature rectennas haw been reported. In this paper, we report the first rectenna designed for 2.45 GHz operation at 500 C. The circuit consists of a microstrip dipole antenna, a stripline impedance matching circuit, and a stripline low pass filter to prevent transmission of higher harmonics created by the rectifying diode fabricated on an Alumina substrate. The rectifying diode is the gate to source junction of a 6H Sic MESFET and the capacitor and load resistor are chip elements that are each bonded to the Alumina substrate. Each element and the hybrid, rectenna circuit haw been characterized through 500 C.
Fluorescence enhancement of photoswitchable metal ion sensors
NASA Astrophysics Data System (ADS)
Sylvia, Georgina; Heng, Sabrina; Abell, Andrew D.
2016-12-01
Spiropyran-based fluorescence sensors are an ideal target for intracellular metal ion sensing, due to their biocompatibility, red emission frequency and photo-controlled reversible analyte binding for continuous signal monitoring. However, increasing the brightness of spiropyran-based sensors would extend their sensing capability for live-cell imaging. In this work we look to enhance the fluorescence of spiropyran-based sensors, by incorporating an additional fluorophore into the sensor design. We report a 5-membered monoazacrown bearing spiropyran with metal ion specificity, modified to incorporate the pyrene fluorophore. The effect of N-indole pyrene modification on the behavior of the spiropyran molecule is explored, with absorbance and fluorescence emission characterization. This first generation sensor provides an insight into fluorescence-enhancement of spiropyran molecules.
Optimizing sensor cover energy for directional sensors
NASA Astrophysics Data System (ADS)
Astorino, Annabella; Gaudioso, Manlio; Miglionico, Giovanna
2016-10-01
The Directional Sensors Continuous Coverage Problem (DSCCP) aims at covering a given set of targets in a plane by means of a set of directional sensors. The location of these sensors is known in advance and they are characterized by a discrete set of possible radii and aperture angles. Decisions to be made are about orientation (which in our approach can vary continuously), radius and aperture angle of each sensor. The objective is to get a minimum cost coverage of all targets, if any. We introduce a MINLP formulation of the problem and define a Lagrangian heuristics based on a dual ascent procedure operating on one multiplier at a time. Finally we report the results of the implementation of the method on a set of test problems.
Quality Factor Effect on the Wireless Range of Microstrip Patch Antenna Strain Sensors
Daliri, Ali; Galehdar, Amir; Rowe, Wayne S. T.; John, Sabu; Wang, Chun H.; Ghorbani, Kamran
2014-01-01
Recently introduced passive wireless strain sensors based on microstrip patch antennas have shown great potential for reliable health and usage monitoring in aerospace and civil industries. However, the wireless interrogation range of these sensors is limited to few centimeters, which restricts their practical application. This paper presents an investigation on the effect of circular microstrip patch antenna (CMPA) design on the quality factor and the maximum practical wireless reading range of the sensor. The results reveal that by using appropriate substrate materials the interrogation distance of the CMPA sensor can be increased four-fold, from the previously reported 5 to 20 cm, thus improving considerably the viability of this type of wireless sensors for strain measurement and damage detection. PMID:24451457
Quality factor effect on the wireless range of microstrip patch antenna strain sensors.
Daliri, Ali; Galehdar, Amir; Rowe, Wayne S T; John, Sabu; Wang, Chun H; Ghorbani, Kamran
2014-01-02
Recently introduced passive wireless strain sensors based on microstrip patch antennas have shown great potential for reliable health and usage monitoring in aerospace and civil industries. However, the wireless interrogation range of these sensors is limited to few centimeters, which restricts their practical application. This paper presents an investigation on the effect of circular microstrip patch antenna (CMPA) design on the quality factor and the maximum practical wireless reading range of the sensor. The results reveal that by using appropriate substrate materials the interrogation distance of the CMPA sensor can be increased four-fold, from the previously reported 5 to 20 cm, thus improving considerably the viability of this type of wireless sensors for strain measurement and damage detection.
Guidelines for spaceborne microwave remote sensors
NASA Technical Reports Server (NTRS)
Litman, V.; Nicholas, J.
1982-01-01
A handbook was developed to provide information and support to the spaceborne remote sensing and frequency management communities: to guide sensor developers in the choice of frequencies; to advise regulators on sensor technology needs and sharing potential; to present sharing analysis models and, through example, methods for determining sensor sharing feasibility; to introduce developers to the regulatory process; to create awareness of proper assignment procedures; to present sensor allocations; and to provide guidelines on the use and limitations of allocated bands. Controlling physical factors and user requirements and the regulatory environment are discussed. Sensor frequency allocation achievable performance and usefulness are reviewed. Procedures for national and international registration, the use of non-allocated bands and steps for obtaining new frequency allocations, and procedures for reporting interference are also discussed.
Energy efficient sensor network implementations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frigo, Janette R; Raby, Eric Y; Brennan, Sean M
In this paper, we discuss a low power embedded sensor node architecture we are developing for distributed sensor network systems deployed in a natural environment. In particular, we examine the sensor node for energy efficient processing-at-the-sensor. We analyze the following modes of operation; event detection, sleep(wake-up), data acquisition, data processing modes using low power, high performance embedded technology such as specialized embedded DSP processors and a low power FPGAs at the sensing node. We use compute intensive sensor node applications: an acoustic vehicle classifier (frequency domain analysis) and a video license plate identification application (learning algorithm) as a case study.more » We report performance and total energy usage for our system implementations and discuss the system architecture design trade offs.« less
Application of remote sensor data to geologic analysis of the Bonanza test site, Colorado
NASA Technical Reports Server (NTRS)
Lee, K. (Compiler)
1972-01-01
A variety of remote sensor data has aided geologic mapping in central Colorado. This report summarizes the application of sensor data to both regional and local geologic mapping and presents some conclusions on the practical use of remote sensing for solving geologic mapping problems. It is emphasized that this study was not conducted primarily to test or evaluate remote sensing systems or data, but, rather, to apply sensor data as an accessory tool for geologic mapping. The remote sensor data used were acquired by the NASA Earth Observations Aircraft Program. Conclusions reached on the utility of the various sensor data and interpretation techniques for geologic mapping were by-products of attempts to use them.
AEDT sensor path methods using BADA4
DOT National Transportation Integrated Search
2017-06-01
This report documents the development and use of sensor path data processing in the Federal Aviation Administration's (FAAs) Aviation Environmental Design Tool (AEDT). The methods are primarily intended to assist analysts with using AEDT to determ...
Fiber optic sensors for infrastructure applications : final report.
DOT National Transportation Integrated Search
1998-02-01
Fiber optic sensor technology offers the possibility of implementing "nervous systems" for infrastructure elements that allow high performance, cost effective health and damage assessment systems to be achieved. This is possible, largely due to syner...
Final report on the portable weather station.
DOT National Transportation Integrated Search
2010-03-01
This station was required to have air temperature, relative humidity, wind speed and direction, and : pavement temperature sensors of similar quality to the traditional RWIS sensors, have an integrated solar : powered battery system, and be trailer...
Integrated active sensor system for real time vibration monitoring.
Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue
2015-11-05
We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0-60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems.
A civil structural monitoring system based on fiber grating sensors
NASA Astrophysics Data System (ADS)
Zhang, Yan; Cai, Haiwen; Pastore, Robert; Ju, Jing; Zeng, Debing; Yin, Zhifan; Cui, Hong-Liang
2003-08-01
Optical fiber sensors based on Fiber Bragg Grating (FBG) technology have found many applications in the area of civil structural monitoring systems, such as in bridge monitoring and maintenance. FBG sensors can measure the deformation, overload and cracks on bridge with a high sensitivity. In this paper we report on our recent work a structural monitoring system using FBG sensors. Basic theoretical background and design of the system is described here, including the light source, FBG sensors, demodulator sensors, signal detection and processing schemes. The system will be installed on a major arch bridge currently under construction in Shanghai, China for long-term in situ health monitoring. The system schematic arrangement on the bridge is introduced in brief. Simulation experiments in the laboratory were carried out to test the performance of FBG strain sensors. The sensor response shows excellent linearity against the strain imposed on it. Traffic and overload monitoring on bridge using FBG sensors is also discussed and planned for the near future.
Integrated active sensor system for real time vibration monitoring
Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue
2015-01-01
We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0–60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems. PMID:26538293
Greene, Barry R; Redmond, Stephen J; Caulfield, Brian
2017-05-01
Falls are the leading global cause of accidental death and disability in older adults and are the most common cause of injury and hospitalization. Accurate, early identification of patients at risk of falling, could lead to timely intervention and a reduction in the incidence of fall-related injury and associated costs. We report a statistical method for fall risk assessment using standard clinical fall risk factors (N = 748). We also report a means of improving this method by automatically combining it, with a fall risk assessment algorithm based on inertial sensor data and the timed-up-and-go test. Furthermore, we provide validation data on the sensor-based fall risk assessment method using a statistically independent dataset. Results obtained using cross-validation on a sample of 292 community dwelling older adults suggest that a combined clinical and sensor-based approach yields a classification accuracy of 76.0%, compared to either 73.6% for sensor-based assessment alone, or 68.8% for clinical risk factors alone. Increasing the cohort size by adding an additional 130 subjects from a separate recruitment wave (N = 422), and applying the same model building and validation method, resulted in a decrease in classification performance (68.5% for combined classifier, 66.8% for sensor data alone, and 58.5% for clinical data alone). This suggests that heterogeneity between cohorts may be a major challenge when attempting to develop fall risk assessment algorithms which generalize well. Independent validation of the sensor-based fall risk assessment algorithm on an independent cohort of 22 community dwelling older adults yielded a classification accuracy of 72.7%. Results suggest that the present method compares well to previously reported sensor-based fall risk assessment methods in assessing falls risk. Implementation of objective fall risk assessment methods on a large scale has the potential to improve quality of care and lead to a reduction in associated hospital costs, due to fewer admissions and reduced injuries due to falling.
Battery-free radio frequency identification (RFID) sensors for food quality and safety
Potyrailo, Radislav A.; Nagraj, Nandini; Tang, Zhexiong; Mondello, Frank J.; Surman, Cheryl; Morris, William
2012-01-01
The market demands for new sensors for food quality and safety stimulate the development of new sensing technologies that can provide an unobtrusive sensor form factor, battery-free operation, and minimal sensor cost. Intelligent labeling of food products to indicate and report their freshness and other conditions is one of important possible applications of such new sensors. We have applied passive (battery-free) radio frequency identification (RFID) sensors for highly sensitive and selective detection of food freshness and bacterial growth. In these sensors, the electric field generated in the RFID sensor antenna extends out from the plane of the RFID sensor and is affected by the ambient environment providing the opportunity for sensing. This environment may be in the form of a food sample within the electric field of the sensing region or a sensing film deposited onto the sensor antenna. Examples of applications include monitoring of freshness of milk, freshness of fish, and bacterial growth in a solution. Unlike other food freshness monitoring approaches that require a thin film battery for operation of an RFID sensor and fabrication of custom-made sensors, our developed passive RFID sensing approach combines advantages of both battery-free and cost-effective sensor design and offers response selectivity that is impossible to achieve with other individual sensors. PMID:22881825
Battery-free radio frequency identification (RFID) sensors for food quality and safety.
Potyrailo, Radislav A; Nagraj, Nandini; Tang, Zhexiong; Mondello, Frank J; Surman, Cheryl; Morris, William
2012-09-05
Market demands for new sensors for food quality and safety stimulate the development of new sensing technologies that can provide an unobtrusive sensor form, battery-free operation, and minimal sensor cost. Intelligent labeling of food products to indicate and report their freshness and other conditions is one important possible application of such new sensors. This study applied passive (battery-free) radio frequency identification (RFID) sensors for the highly sensitive and selective detection of food freshness and bacterial growth. In these sensors, the electric field generated in the RFID sensor antenna extends from the plane of the RFID sensor and is affected by the ambient environment, providing the opportunity for sensing. This environment may be in the form of a food sample within the electric field of the sensing region or a sensing film deposited onto the sensor antenna. Examples of applications include monitoring of milk freshness, fish freshness, and bacterial growth in a solution. Unlike other food freshness monitoring approaches that require a thin film battery for operation of an RFID sensor and fabrication of custom-made sensors, the passive RFID sensing approach developed here combines the advantages of both battery-free and cost-effective sensor design and offers response selectivity that is impossible to achieve with other individual sensors.
NASA Astrophysics Data System (ADS)
Han, Maeum; Keon Kim, Jae; Kong, Seong Ho; Kang, Shin-Won; Jung, Daewoong
2018-06-01
This paper reports a micro-electro-mechanical-system (MEMS)-based tilt sensor using air medium. Since the working mechanism of the sensor is the thermal convection in a sealed chamber, structural parameters that can affect thermal convection must be considered to optimize the performance of the sensor. This paper presents the experimental results that were conducted by optimizing several parameters such as the heater geometry, input power and cavity volume. We observed that an increase in the heating power and cavity volume can improve the sensitivity, and heater geometry plays important role in performance of the sensor.
High-performance flexible hydrogen sensor made of WS2 nanosheet-Pd nanoparticle composite film
NASA Astrophysics Data System (ADS)
Kuru, Cihan; Choi, Duyoung; Kargar, Alireza; Liu, Chin Hung; Yavuz, Serdar; Choi, Chulmin; Jin, Sungho; Bandaru, Prabhakar R.
2016-05-01
We report a flexible hydrogen sensor, composed of WS2 nanosheet-Pd nanoparticle composite film, fabricated on a flexible polyimide substrate. The sensor offers the advantages of light-weight, mechanical durability, room temperature operation, and high sensitivity. The WS2-Pd composite film exhibits sensitivity (R 1/R 2, the ratio of the initial resistance to final resistance of the sensor) of 7.8 to 50 000 ppm hydrogen. Moreover, the WS2-Pd composite film distinctly outperforms the graphene-Pd composite, whose sensitivity is only 1.14. Furthermore, the ease of fabrication holds great potential for scalable and low-cost manufacturing of hydrogen sensors.
Application of the Solubility Parameter Concept to the Design of Chemiresistor Arrays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eastman, M.P.; Hughes, R.C.; Jenkins, M.W.
1999-01-11
Arrays of unheated chemically sensitive resistors (chemiresistors) can serve as extremely small, low-power-consumption sensors with simple read-out electronics. We report here results on carbon-loaded polymer composites, as well as polymeric ionic conductors, as chemiresistor sensors. We use the volubility parameter concept to understand and categorize the chemiresistor responses and, in particular, we compare chemiresistors fabricated from polyisobutylene (PIB) to results from PIB-coated acoustic wave sensors. One goal is to examine the possibility that a small number of diverse chemiresistors can sense all possible solvents-the "Universal Solvent Sensor Array". keywords: chemiresistor, volubility parameter, chemical sensor
Overview of Sensors and Needs for Environmental Monitoring
Ho, Clifford K.; Robinson, Alex; Miller, David R.; Davis, Mary J.
2005-01-01
This paper surveys the needs associated with environmental monitoring and long-term environmental stewardship. Emerging sensor technologies are reviewed to identify compatible technologies for various environmental monitoring applications. The contaminants that are considered in this report are grouped into the following categories: (1) metals, (2) radioisotopes, (3) volatile organic compounds, and (4) biological contaminants. United States regulatory drivers are evaluated for different applications (e.g., drinking water, storm water, pretreatment, and air emissions), and sensor requirements are derived from these regulatory metrics. Sensor capabilities are then summarized according to contaminant type, and the applicability of the different sensors to various environmental monitoring applications is discussed.
Plasmon waveguide resonance sensor using an Au-MgF2 structure.
Zhou, Yanfei; Zhang, Pengfei; He, Yonghong; Xu, Zihao; Liu, Le; Ji, Yanhong; Ma, Hui
2014-10-01
We report an Au − MgF(2) plasmon waveguide resonance (PWR) sensor in this work. The characteristics of this sensing structure are compared with a surface plasmon resonance (SPR) structure theoretically and experimentally. The transverse-magnetic-polarized PWR sensor has a refractive index resolution of 9.3 × 10(-7) RIU, which is 6 times smaller than that of SPR at the incident light wavelength of 633 nm, and the transverse-electric-polarized PWR sensor has a refractive index resolution of 3.0 × 10(-6) RIU. This high-resolution sensor is easy to build and is less sensitive to film coating deviations.
Reputation-Based Secure Sensor Localization in Wireless Sensor Networks
He, Jingsha; Xu, Jing; Zhu, Xingye; Zhang, Yuqiang; Zhang, Ting; Fu, Wanqing
2014-01-01
Location information of sensor nodes in wireless sensor networks (WSNs) is very important, for it makes information that is collected and reported by the sensor nodes spatially meaningful for applications. Since most current sensor localization schemes rely on location information that is provided by beacon nodes for the regular sensor nodes to locate themselves, the accuracy of localization depends on the accuracy of location information from the beacon nodes. Therefore, the security and reliability of the beacon nodes become critical in the localization of regular sensor nodes. In this paper, we propose a reputation-based security scheme for sensor localization to improve the security and the accuracy of sensor localization in hostile or untrusted environments. In our proposed scheme, the reputation of each beacon node is evaluated based on a reputation evaluation model so that regular sensor nodes can get credible location information from highly reputable beacon nodes to accomplish localization. We also perform a set of simulation experiments to demonstrate the effectiveness of the proposed reputation-based security scheme. And our simulation results show that the proposed security scheme can enhance the security and, hence, improve the accuracy of sensor localization in hostile or untrusted environments. PMID:24982940
Near-IR Two-Photon Fluorescent Sensor for K(+) Imaging in Live Cells.
Sui, Binglin; Yue, Xiling; Kim, Bosung; Belfield, Kevin D
2015-08-19
A new two-photon excited fluorescent K(+) sensor is reported. The sensor comprises three moieties, a highly selective K(+) chelator as the K(+) recognition unit, a boron-dipyrromethene (BODIPY) derivative modified with phenylethynyl groups as the fluorophore, and two polyethylene glycol chains to afford water solubility. The sensor displays very high selectivity (>52-fold) in detecting K(+) over other physiological metal cations. Upon binding K(+), the sensor switches from nonfluorescent to highly fluorescent, emitting red to near-IR (NIR) fluorescence. The sensor exhibited a good two-photon absorption cross section, 500 GM at 940 nm. Moreover, it is not sensitive to pH in the physiological pH range. Time-dependent cell imaging studies via both one- and two-photon fluorescence microscopy demonstrate that the sensor is suitable for dynamic K(+) sensing in living cells.
Conductive polymer nanowire gas sensor fabricated by nanoscale soft lithography
NASA Astrophysics Data System (ADS)
Tang, Ning; Jiang, Yang; Qu, Hemi; Duan, Xuexin
2017-12-01
Resistive devices composed of one-dimensional nanostructures are promising candidates for the next generation of gas sensors. However, the large-scale fabrication of nanowires is still challenging, which restricts the commercialization of such devices. Here, we report a highly efficient and facile approach to fabricating poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) nanowire chemiresistive gas sensors by nanoscale soft lithography. Well-defined sub-100 nm nanowires are fabricated on silicon substrate, which facilitates device integration. The nanowire chemiresistive gas sensor is demonstrated for NH3 and NO2 detection at room temperature and shows a limit of detection at ppb level, which is compatible with nanoscale PEDOT:PSS gas sensors fabricated with the conventional lithography technique. In comparison with PEDOT:PSS thin-film gas sensors, the nanowire gas sensor exhibits higher sensitivity and a much faster response to gas molecules.
Conductive polymer nanowire gas sensor fabricated by nanoscale soft lithography.
Tang, Ning; Jiang, Yang; Qu, Hemi; Duan, Xuexin
2017-12-01
Resistive devices composed of one-dimensional nanostructures are promising candidates for the next generation of gas sensors. However, the large-scale fabrication of nanowires is still challenging, which restricts the commercialization of such devices. Here, we report a highly efficient and facile approach to fabricating poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) nanowire chemiresistive gas sensors by nanoscale soft lithography. Well-defined sub-100 nm nanowires are fabricated on silicon substrate, which facilitates device integration. The nanowire chemiresistive gas sensor is demonstrated for NH 3 and NO 2 detection at room temperature and shows a limit of detection at ppb level, which is compatible with nanoscale PEDOT:PSS gas sensors fabricated with the conventional lithography technique. In comparison with PEDOT:PSS thin-film gas sensors, the nanowire gas sensor exhibits higher sensitivity and a much faster response to gas molecules.
High sensitivity knitted fabric strain sensors
NASA Astrophysics Data System (ADS)
Xie, Juan; Long, Hairu; Miao, Menghe
2016-10-01
Wearable sensors are increasingly used in smart garments for detecting and transferring vital signals and body posture, movement and respiration. Existing fabric strain sensors made from metallized yarns have low sensitivity, poor comfort and low durability to washing. Here we report a knitted fabric strain sensor made from a cotton/stainless steel (SS) fibre blended yarn which shows much higher sensitivity than sensors knitted from metallized yarns. The fabric feels softer than pure cotton textiles owing to the ultrafine stainless steel fibres and does not lose its electrical property after washing. The reason for the high sensitivity of the cotton/SS knitted fabric sensor was explored by comparing its sensing mechanism with the knitted fabric sensor made from metallized yarns. The results show that the cotton/SS yarn-to-yarn contact resistance is highly sensitive to strain applied to hooked yarn loops.
Performance Evaluation of Five Turbidity Sensors in Three Primary Standards
Snazelle, Teri T.
2015-10-28
Open-File Report 2015-1172 is temporarily unavailable.Five commercially available turbidity sensors were evaluated by the U.S. Geological Survey, Hydrologic Instrumentation Facility (HIF) for accuracy and precision in three types of turbidity standards; formazin, StablCal, and AMCO Clear (AMCO–AEPA). The U.S. Environmental Protection Agency (EPA) recognizes all three turbidity standards as primary standards, meaning they are acceptable for reporting purposes. The Forrest Technology Systems (FTS) DTS-12, the Hach SOLITAX sc, the Xylem EXO turbidity sensor, the Yellow Springs Instrument (YSI) 6136 turbidity sensor, and the Hydrolab Series 5 self-cleaning turbidity sensor were evaluated to determine if turbidity measurements in the three primary standards are comparable to each other, and to ascertain if the primary standards are truly interchangeable. A formazin 4000 nephelometric turbidity unit (NTU) stock was purchased and dilutions of 40, 100, 400, 800, and 1000 NTU were made fresh the day of testing. StablCal and AMCO Clear (for Hach 2100N) standards with corresponding concentrations were also purchased for the evaluation. Sensor performance was not evaluated in turbidity levels less than 40 NTU due to the unavailability of polymer-bead turbidity standards rated for general use. The percent error was calculated as the true (not absolute) difference between the measured turbidity and the standard value, divided by the standard value.The sensors that demonstrated the best overall performance in the evaluation were the Hach SOLITAX and the Hydrolab Series 5 turbidity sensor when the operating range (0.001–4000 NTU for the SOLITAX and 0.1–3000 NTU for the Hydrolab) was considered in addition to sensor accuracy and precision. The average percent error in the three standards was 3.80 percent for the SOLITAX and -4.46 percent for the Hydrolab. The DTS-12 also demonstrated good accuracy with an average percent error of 2.02 percent and a maximum relative standard deviation of 0.51 percent for the operating range, which was limited to 0.01–1600 NTU at the time of this report. Test results indicated an average percent error of 19.81 percent in the three standards for the EXO turbidity sensor and 9.66 percent for the YSI 6136. The significant variability in sensor performance in the three primary standards suggests that although all three types are accepted as primary calibration standards, they are not interchangeable, and sensor results in the three types of standards are not directly comparable.
Extended Testability Analysis Tool
NASA Technical Reports Server (NTRS)
Melcher, Kevin; Maul, William A.; Fulton, Christopher
2012-01-01
The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.
Component and Technology Development for Advanced Liquid Metal Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Mark
2017-01-30
The following report details the significant developments to Sodium Fast Reactor (SFR) technologies made throughout the course of this funding. This report will begin with an overview of the sodium loop and the improvements made over the course of this research to make it a more advanced and capable facility. These improvements have much to do with oxygen control and diagnostics. Thus a detailed report of advancements with respect to the cold trap, plugging meter, vanadium equilibration loop, and electrochemical oxygen sensor is included. Further analysis of the university’s moving magnet pump was performed and included in a section ofmore » this report. A continuous electrical resistance based level sensor was built and tested in the sodium with favorable results. Materials testing was done on diffusion bonded samples of metal and the results are presented here as well. A significant portion of this work went into the development of optical fiber temperature sensors which could be deployed in an SFR environment. Thus, a section of this report presents the work done to develop an encapsulation method for these fibers inside of a stainless steel capillary tube. High temperature testing was then done on the optical fiber ex situ in a furnace. Thermal response time was also explored with the optical fiber temperature sensors. Finally these optical fibers were deployed successfully in a sodium environment for data acquisition. As a test of the sodium deployable optical fiber temperature sensors they were installed in a sub-loop of the sodium facility which was constructed to promote the thermal striping effect in sodium. The optical fibers performed exceptionally well, yielding unprecedented 2 dimensional temperature profiles with good temporal resolution. Finally, this thermal striping loop was used to perform cross correlation velocimetry successfully over a wide range of flow rates.« less
INL Control System Situational Awareness Technology Annual Report 2012
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon Rueff; Bryce Wheeler; Todd Vollmer
The overall goal of this project is to develop an interoperable set of tools to provide a comprehensive, consistent implementation of cyber security and overall situational awareness of control and sensor network implementations. The operation and interoperability of these tools will fill voids in current technological offerings and address issues that remain an impediment to the security of control systems. This report provides an FY 2012 update on the Sophia, Mesh Mapper, Intelligent Cyber Sensor, and Data Fusion projects with respect to the year-two tasks and annual reporting requirements of the INL Control System Situational Awareness Technology report (July 2010).
Detecting Human Activity Using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors
2011-09-01
Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors by Sarah H. Walker and Geoffrey H. Goldman...Adelphi, MD 20783-1197 ARL-TR-5729 September 2011 Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors...DD-MM-YYYY) September 2011 2. REPORT TYPE 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Detecting Human Activity using Acoustic
JPRS Report Science & Technology Japan
1989-06-02
Electronics •Superconducting Wiring in LSI •One Wafer Computer •Josephson Devices •SQUID Devices Infrared Sensor Magnetic Sensor •Superconducting...Guinier- de Wolff monochromatic focusing camera (CoK* radiation) and with Philips APD-10 auto-powder diffractometer (CuKÄ radiation). Pure Si was used as...crystallized and smooth surface. The values indicated in Fig. 2 were the thickness monitored by a quartz oscillating sensor located near the
Modified Hyperbranched Polymers for Fluorescence Sensing Applications
2012-06-01
sensors. The HBPs transported the fluorescent groups to the fiber mat surface where they interacted with mercury (Hg(II)) or cytochrome c as the analyte...coworkers (27, 28) have employed fluorescence quenching using a binol-based dendrimer sensor, which exhibited differential sensitivity to enantiomeric...based sensors using HBP-based fluorophores was demonstrated in this report. Low concentrations of fluorophore were transported to the surface of
Distributed sensor for water and pH measurements using fiber optics and swellable polymeric systems
NASA Astrophysics Data System (ADS)
Michie, W. C.; Culshaw, B.; McKenzie, I.; Konstantakis, M.; Graham, N. B.; Moran, C.; Santos, F.; Bergqvist, E.; Carlstrom, B.
1995-01-01
We report on the design, construction and test of a generic form of sensor for making distributed measurements of a range of chemical parameters. The technique combines optical time-domain reflectometry with chemically sensitive water-swellable polymers (hydrogels). Initial experiments have concentrated on demonstrating a distributed water detector; however, gels have been developed that enable this sensor to be
CMOS Active Pixel Sensor Star Tracker with Regional Electronic Shutter
NASA Technical Reports Server (NTRS)
Yadid-Pecht, Orly; Pain, Bedabrata; Staller, Craig; Clark, Christopher; Fossum, Eric
1996-01-01
The guidance system in a spacecraft determines spacecraft attitude by matching an observed star field to a star catalog....An APS(active pixel sensor)-based system can reduce mass and power consumption and radiation effects compared to a CCD(charge-coupled device)-based system...This paper reports an APS (active pixel sensor) with locally variable times, achieved through individual pixel reset (IPR).
USDA-ARS?s Scientific Manuscript database
The article by Singh et al., (2018) provides a striking example of the wide range of soil water contents reported by several electromagnetic (EM) sensor technologies under field conditions. We commend the authors for taking the initiative to evaluate these sensors in the field and in situations wher...
Validation Test Report for the Automated Optical Processing System (AOPS) Version 4.12
2015-09-03
NPP) with the VIIRS sensor package as well as data from the Geostationary Ocean Color Imager (GOCI) sensor, aboard the Communication Ocean and...capability • Prepare the NRT Geostationary Ocean Color Imager (GOCI) data stream for integration into operations. • Improvements in sensor...Navy (DON) Environmental Data Records (EDRs) Expeditionary Warfare (EXW) Geostationary Ocean Color Imager (GOCI) Gulf of Mexico (GOM) Hierarchical
NASA Astrophysics Data System (ADS)
Park, Jihun; Kim, Joohee; Kim, Kukjoo; Kim, So-Yun; Cheong, Woon Hyung; Park, Kyeongmin; Song, Joo Hyeb; Namgoong, Gyeongho; Kim, Jae Joon; Heo, Jaeyeong; Bien, Franklin; Park, Jang-Ung
2016-05-01
Herein, we report the fabrication of a highly stretchable, transparent gas sensor based on silver nanowire-graphene hybrid nanostructures. Due to its superb mechanical and optical characteristics, the fabricated sensor demonstrates outstanding and stable performances even under extreme mechanical deformation (stable until 20% of strain). The integration of a Bluetooth system or an inductive antenna enables the wireless operation of the sensor. In addition, the mechanical robustness of the materials allows the device to be transferred onto various nonplanar substrates, including a watch, a bicycle light, and the leaves of live plants, thereby achieving next-generation sensing electronics for the `Internet of Things' area.Herein, we report the fabrication of a highly stretchable, transparent gas sensor based on silver nanowire-graphene hybrid nanostructures. Due to its superb mechanical and optical characteristics, the fabricated sensor demonstrates outstanding and stable performances even under extreme mechanical deformation (stable until 20% of strain). The integration of a Bluetooth system or an inductive antenna enables the wireless operation of the sensor. In addition, the mechanical robustness of the materials allows the device to be transferred onto various nonplanar substrates, including a watch, a bicycle light, and the leaves of live plants, thereby achieving next-generation sensing electronics for the `Internet of Things' area. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr01468b
Bazzazi, Hojjat; Sang, Lingjie; Dick, Ivy E; Joshi-Mukherjee, Rosy; Yang, Wanjun; Yue, David T
2015-01-01
Abstract The phosphatase calcineurin is a central component of many calcium signalling pathways, relaying calcium signals from the plasma membrane to the nucleus. It has critical functions in a multitude of systems, including immune, cardiac and neuronal. Given the widespread importance of calcineurin in both normal and pathological conditions, new tools that elucidate the spatiotemporal dynamics of calcineurin activity would be invaluable. Here we develop two separate genetically encoded fluorescence resonance energy transfer (FRET)-based sensors of calcineurin activation, DuoCaN and UniCaN. Both sensors showcase a large dynamic range and rapid response kinetics, differing primarily in the linker structure between the FRET pairs. Both sensors were calibrated in HEK293 cells and their responses correlated well with NFAT translocation to the nucleus, validating the biological relevance of the sensor readout. The sensors were subsequently expressed in neonatal rat ventricular myocytes and acutely isolated adult guinea pig ventricular myocytes. Both sensors demonstrated robust responses in myocytes and revealed kinetic differences in calcineurin activation during changes in pacing rate for neonatal versus adult myocytes. Finally, mathematical modelling combined with quantitative FRET measurements provided novel insights into the kinetics and integration of calcineurin activation in response to myocyte Ca transients. In all, DuoCaN and UniCaN stand as valuable new tools for understanding the role of calcineurin in normal and pathological signalling. Key points Novel fluorescence resonance energy transfer-based genetically encoded reporters of calcineurin are constructed by fusing the two subunits of calcineurin with P2A-based linkers retaining the expected native conformation of calcineurin. Calcineurin reporters display robust responses to calcium transients in HEK293 cells. The sensor responses are correlated with NFATc1 translocation dynamics in HEK293 cells. The sensors are uniformly distributed in neonatal myocytes and respond efficiently to single electrically evoked calcium transients and show cumulative activation at frequencies of 0.5 and 1 Hz. In adult myocytes, the calcineurin sensors appear to be localized to the cardiac z-lines, and respond to cumulative calcium transients at frequencies of 0.5 and 1 Hz. PMID:26096996
Highly Stretchable and Transparent Microfluidic Strain Sensors for Monitoring Human Body Motions.
Yoon, Sun Geun; Koo, Hyung-Jun; Chang, Suk Tai
2015-12-16
We report a new class of simple microfluidic strain sensors with high stretchability, transparency, sensitivity, and long-term stability with no considerable hysteresis and a fast response to various deformations by combining the merits of microfluidic techniques and ionic liquids. The high optical transparency of the strain sensors was achieved by introducing refractive-index matched ionic liquids into microfluidic networks or channels embedded in an elastomeric matrix. The microfluidic strain sensors offer the outstanding sensor performance under a variety of deformations induced by stretching, bending, pressing, and twisting of the microfluidic strain sensors. The principle of our microfluidic strain sensor is explained by a theoretical model based on the elastic channel deformation. In order to demonstrate its capability of practical usage, the simple-structured microfluidic strain sensors were performed onto a finger, wrist, and arm. The highly stretchable and transparent microfluidic strain sensors were successfully applied as potential platforms for distinctively monitoring a wide range of human body motions in real time. Our novel microfluidic strain sensors show great promise for making future stretchable electronic devices.
Evaluation of sensor arrays for engine oils using artificial oil alteration
NASA Astrophysics Data System (ADS)
Sen, Sedat; Schneidhofer, Christoph; Dörr, Nicole; Vellekoop, Michael J.
2011-06-01
With respect to varying operation conditions, only sensors directly installed in the engine can detect the current oil condition hence enabling to get the right time for the oil change. Usually, only one parameter is not sufficient to obtain reliable information about the current oil condition. For this reason, appropriate sensor principles were evaluated for the design of sensor arrays for the measurement of critical lubricant parameters. In this contribution, we report on the development of a sensor array for engine oils using laboratory analyses of used engine oils for the correlation with sensor signals. The sensor array comprises the measurement of conductivity, permittivity, viscosity and temperature as well as oil corrosiveness as a consequence of acidification of the lubricant. As a key method, rapid evaluation of the sensors was done by short term simulation of entire oil change intervals based on artificial oil alteration. Thereby, the compatibility of the sensor array to the lubricant and the oil deterioration during the artificial alteration process was observed by the sensors and confirmed by additional laboratory analyses of oil samples take.
NASA Astrophysics Data System (ADS)
Unno, Y.; Edwards, S. O.; Pyatt, S.; Thomas, J. P.; Wilson, J. A.; Kierstead, J.; Lynn, D.; Carter, J. R.; Hommels, L. B. A.; Robinson, D.; Bloch, I.; Gregor, I. M.; Tackmann, K.; Betancourt, C.; Jakobs, K.; Kuehn, S.; Mori, R.; Parzefall, U.; Wiik-Fucks, L.; Clark, A.; Ferrere, D.; Gonzalez Sevilla, S.; Ashby, J.; Blue, A.; Bates, R.; Buttar, C.; Doherty, F.; Eklund, L.; McMullen, T.; McEwan, F.; O`Shea, V.; Kamada, S.; Yamamura, K.; Ikegami, Y.; Nakamura, K.; Takubo, Y.; Nishimura, R.; Takashima, R.; Chilingarov, A.; Fox, H.; Affolder, A. A.; Allport, P. P.; Casse, G.; Dervan, P.; Forshaw, D.; Greenall, A.; Wonsak, S.; Wormald, M.; Cindro, V.; Kramberger, G.; Mandic, I.; Mikuz, M.; Gorelov, I.; Hoeferkamp, M.; Palni, P.; Seidel, S.; Taylor, A.; Toms, K.; Wang, R.; Hessey, N. P.; Valencic, N.; Arai, Y.; Hanagaki, K.; Dolezal, Z.; Kodys, P.; Bohm, J.; Mikestikova, M.; Bevan, A.; Beck, G.; Ely, S.; Fadeyev, V.; Galloway, Z.; Grillo, A. A.; Martinez-McKinney, F.; Ngo, J.; Parker, C.; Sadrozinski, H. F.-W.; Schumacher, D.; Seiden, A.; French, R.; Hodgson, P.; Marin-Reyes, H.; Parker, K.; Paganis, S.; Jinnouchi, O.; Motohashi, K.; Todome, K.; Yamaguchi, D.; Hara, K.; Hagihara, M.; Garcia, C.; Jimenez, J.; Lacasta, C.; Marti i Garcia, S.; Soldevila, U.
2014-11-01
We have been developing a novel radiation-tolerant n+-in-p silicon microstrip sensor for very high radiation environments, aiming for application in the high luminosity large hadron collider. The sensors are fabricated in 6 in., p-type, float-zone wafers, where large-area strip sensor designs are laid out together with a number of miniature sensors. Radiation tolerance has been studied with ATLAS07 sensors and with independent structures. The ATLAS07 design was developed into new ATLAS12 designs. The ATLAS12A large-area sensor is made towards an axial strip sensor and the ATLAS12M towards a stereo strip sensor. New features to the ATLAS12 sensors are two dicing lines: standard edge space of 910 μm and slim edge space of 450 μm, a gated punch-through protection structure, and connection of orphan strips in a triangular corner of stereo strips. We report the design of the ATLAS12 layouts and initial measurements of the leakage current after dicing and the resistivity of the wafers.
Continued Development of Compact Multi-Gas Monitor for Life Support Systems Control in Space
NASA Technical Reports Server (NTRS)
Delgado-Alonso, Jesus; Phillips, Straun; Berry, David; DiCarmine, Paul; Chullen, Cinda; Quinn, Gregory
2016-01-01
Miniature optical gas sensors based on luminescent materials have shown great potential as alternatives to NIR-based gas sensor systems for the Portable Life Support System (PLSS). The unique capability of luminescent sensors for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages over both traditional and advanced non-dispersive infrared (NDIR) gas sensors, which have so far shown longer life than luminescent sensors. In this paper we present the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted in Intelligent Optical Systems laboratories, a United Technologies Corporation Aerospace Systems (UTC) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems, and the advantages and limitations found through detailed sensor validation are discussed.
DOT National Transportation Integrated Search
2016-03-01
This report summarizes an initial stage investigation into wearable sensors for transportation research : applications. The Federal Highway Administration (FHWA) has observed significant activity in this area and : seeks to obtain an understanding of...
Integrated optics ring-resonator chemical sensor for detection of air contamination
NASA Technical Reports Server (NTRS)
Manfreda, A. M.; Homer, M. L.; Ksendzov, A.
2004-01-01
We report a silicon nitride-based ring resonator chemical sensor with sensing polymer coating. Its sensitivity to isopropanol in air is at least 50 ppm - well under the permissible exposure level of 400 ppm.
Intregrated optics ring-resonator chemical sensor for detection of air contamination
NASA Technical Reports Server (NTRS)
Ksendzov, Alexander; Homer, Margie L.; Manfreda, Allison M.
2004-01-01
We report a silicon nitride-based ring resonator chemical sensor with sensing polymer coating. Its sensitivity to isopropanol in air is at least 50 ppm - well under the permissible exposure level of 400 ppm.
Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires
NASA Astrophysics Data System (ADS)
Yao, Shanshan; Zhu, Yong
2014-01-01
Considerable efforts have been made to achieve highly sensitive and wearable sensors that can simultaneously detect multiple stimuli such as stretch, pressure, temperature or touch. Here we develop highly stretchable multifunctional sensors that can detect strain (up to 50%), pressure (up to ~1.2 MPa) and finger touch with high sensitivity, fast response time (~40 ms) and good pressure mapping function. The reported sensors utilize the capacitive sensing mechanism, where silver nanowires are used as electrodes (conductors) and Ecoflex is used as a dielectric. The silver nanowire electrodes are screen printed. Our sensors have been demonstrated for several wearable applications including monitoring thumb movement, sensing the strain of the knee joint in patellar reflex (knee-jerk) and other human motions such as walking, running and jumping from squatting, illustrating the potential utilities of such sensors in robotic systems, prosthetics, healthcare and flexible touch panels.Considerable efforts have been made to achieve highly sensitive and wearable sensors that can simultaneously detect multiple stimuli such as stretch, pressure, temperature or touch. Here we develop highly stretchable multifunctional sensors that can detect strain (up to 50%), pressure (up to ~1.2 MPa) and finger touch with high sensitivity, fast response time (~40 ms) and good pressure mapping function. The reported sensors utilize the capacitive sensing mechanism, where silver nanowires are used as electrodes (conductors) and Ecoflex is used as a dielectric. The silver nanowire electrodes are screen printed. Our sensors have been demonstrated for several wearable applications including monitoring thumb movement, sensing the strain of the knee joint in patellar reflex (knee-jerk) and other human motions such as walking, running and jumping from squatting, illustrating the potential utilities of such sensors in robotic systems, prosthetics, healthcare and flexible touch panels. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr05496a
Tang, Lijun; Huang, Zhenlong; Zheng, Zhuxuan; Zhong, Keli; Bian, Yanjiang
2016-09-01
Selective fluorescence turn on Zn(2+) sensor with long-wavelength emission and a large Stokes shift is highly desirable in Zn(2+) sensing area. We reported herein the synthesis and Zn(2+) recognition properties of a new thiosemicarbazone-based fluorescent sensor L. L displays high selectivity and sensitivity toward Zn(2+) over other metal ions in DMSO-H2O (1:1, v/v, HEPES 10 mM, pH = 7.4) solution with a long-wavelength emission at 572 nm and a large Stokes shift of 222 nm. Confocal fluorescence microscopy experiments demonstrate that L is cell-permeable and capable of monitoring intracellular Zn(2+). Graphical Abstract We report a new thiosemicarbazone-based fluorescent sensor (L) for selective recognition of Zn(2+) with a long wavelength emission and a large Stokes shift.
A 1 GHz Oscillator-Type Active Antenna
NASA Technical Reports Server (NTRS)
Jordan, Jennifer L.; Scardelletti, Maximilian; Ponchak, George E.
2008-01-01
Wireless sensors are desired for monitoring aircraft engines, automotive engines, industrial machinery, and many other applications. The most important requirement of sensors is that they do not interfere with the environment that they are monitoring. Therefore, wireless sensors must be small, which demands a high level of integration. Sensors that modulate an oscillator active antenna have advantages of small size, high level of integration, and lower packaging cost. Several types of oscillator active antennas have been reported. Ip et al. demonstrated a CPW line fed patch antenna with a feedback loop [1]. No degradation in performance was noticed without a ground plane. A GaAs FET was used in an amplifier/oscillator-based active antenna [2]. An oscillator based on a Cree SiC transistor was designed and characterized in [3]. This paper reports the integration of the SiC Clapp oscillator to a slotline loop antenna.
Dong, Lei; Li, Chunguang; Sanchez, Nancy P.; ...
2016-01-05
A tunable diode laser absorption spectroscopy-based methane sensor, employing a dense-pattern multi-pass gas cell and a 3.3 µm, CW, DFB, room temperature interband cascade laser (ICL), is reported. The optical integration based on an advanced folded optical path design and an efficient ICL control system with appropriate electrical power management resulted in a CH 4 sensor with a small footprint (32 x 20 x 17 cm 3) and low-power consumption (6 W). Polynomial and least-squares fit algorithms are employed to remove the baseline of the spectral scan and retrieve CH 4 concentrations, respectively. An Allan-Werle deviation analysis shows that themore » measurement precision can reach 1.4 ppb for a 60 s averaging time. Continuous measurements covering a seven-day period were performed to demonstrate the stability and robustness of the reported CH 4 sensor system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Lei; Li, Chunguang; Sanchez, Nancy P.
A tunable diode laser absorption spectroscopy-based methane sensor, employing a dense-pattern multi-pass gas cell and a 3.3 µm, CW, DFB, room temperature interband cascade laser (ICL), is reported. The optical integration based on an advanced folded optical path design and an efficient ICL control system with appropriate electrical power management resulted in a CH 4 sensor with a small footprint (32 x 20 x 17 cm 3) and low-power consumption (6 W). Polynomial and least-squares fit algorithms are employed to remove the baseline of the spectral scan and retrieve CH 4 concentrations, respectively. An Allan-Werle deviation analysis shows that themore » measurement precision can reach 1.4 ppb for a 60 s averaging time. Continuous measurements covering a seven-day period were performed to demonstrate the stability and robustness of the reported CH 4 sensor system.« less
Non-Contact Detection of Breathing Using a Microwave Sensor
Dei, Devis; Grazzini, Gilberto; Luzi, Guido; Pieraccini, Massimiliano; Atzeni, Carlo; Boncinelli, Sergio; Camiciottoli, Gianna; Castellani, Walter; Marsili, Massimo; Dico, Juri Lo
2009-01-01
In this paper the use of a continuous-wave microwave sensor as a non-contact tool for quantitative measurement of respiratory tidal volume has been evaluated by experimentation in seventeen healthy volunteers. The sensor working principle is reported and several causes that can affect its response are analyzed. A suitable data processing has been devised able to reject the majority of breath measurements taken under non suitable conditions. Furthermore, a relationship between microwave sensor measurements and volume inspired and expired at quiet breathing (tidal volume) has been found. PMID:22574033
Slot-waveguide biochemical sensor.
Barrios, Carlos A; Gylfason, Kristinn B; Sánchez, Benito; Griol, Amadeu; Sohlström, H; Holgado, M; Casquel, R
2007-11-01
We report an experimental demonstration of an integrated biochemical sensor based on a slot-waveguide microring resonator. The microresonator is fabricated on a Si3N4-SiO2 platform and operates at a wavelength of 1.3 microm. The transmission spectrum of the sensor is measured with different ambient refractive indices ranging from n=1.33 to 1.42. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. The sensor detects a minimal refractive index variation of 2x10(-4) RIU.
NASA Astrophysics Data System (ADS)
Kim, Ki-Soo; Cho, Seong-Kyu
2015-07-01
The FBG sensor has globally been commercialized in various fields that is actively applied in Korea as well. Especially it is widely used as a structural monitoring sensor in civil engineering and construction structures due to its advantages including electrical stability, chemical stability and multiplexing. This report aims to introduce safety inspection of the FBG sensor in respect of radioactivity which has been applied to a silo structure for radioactive waste disposal as an example.
High-temperature fiber optic pressure sensor
NASA Technical Reports Server (NTRS)
Berthold, J. W.
1984-01-01
Attention is given to a program to develop fiber optic methods to measure diaphragm deflection. The end application is intended for pressure transducers capable of operating to 540 C. In this paper are reported the results of a laboratory study to characterize the performance of the fiber-optic microbend sensor. The data presented include sensitivity and spring constant. The advantages and limitations of the microbend sensor for static pressure measurement applications are described. A proposed design is presented for a 540 C pressure transducer using the fiber optic microbend sensor.
CMOS sensor as charged particles and ionizing radiation detector
NASA Astrophysics Data System (ADS)
Cruz-Zaragoza, E.; Piña López, I.
2015-01-01
This paper reports results of CMOS sensor suitable for use as charged particles and ionizing radiation detector. The CMOS sensor with 640 × 480 pixels area has been integrated into an electronic circuit for detection of ionizing radiation and it was exposed to alpha particle (Am-241, Unat), beta (Sr-90), and gamma photons (Cs-137). Results show after long period of time (168 h) irradiation the sensor had not loss of functionality and also the energy of the charge particles and photons were very well obtained.
De Jonckheere, J; Narbonneau, F; Jeanne, M; Kinet, D; Witt, J; Krebber, K; Paquet, B; Depre, A; Logier, R
2009-01-01
The potential impact of optical fiber sensors embedded into medical textiles for the continuous monitoring of the patient during Magnetic Resonance Imaging is presented. We report on two pure optical sensing technologies for respiratory movements monitoring - a macro bending sensor and a Bragg grating sensor, designed to measure the elongation due to abdominal and thoracic motions during breathing. We demonstrate that the two sensors can successfully sense textile elongation between, 0% and 3%, while maintaining the stretching properties of the textile substrates for a good comfort of the patient.
Applications of Nuclear Magnetic Resonance Sensors to Cultural Heritage
Proietti, Noemi; Capitani, Donatella; Di Tullio, Valeria
2014-01-01
In recent years nuclear magnetic resonance (NMR) sensors have been increasingly applied to investigate, characterize and monitor objects of cultural heritage interest. NMR is not confined to a few specific applications, but rather its use can be successfully extended to a wide number of different cultural heritage issues. A breakthrough has surely been the recent development of portable NMR sensors which can be applied in situ for non-destructive and non-invasive investigations. In this paper three studies illustrating the potential of NMR sensors in this field of research are reported. PMID:24755519
Metal oxide gas sensors on the nanoscale
NASA Astrophysics Data System (ADS)
Plecenik, A.; Haidry, A. A.; Plecenik, T.; Durina, P.; Truchly, M.; Mosko, M.; Grancic, B.; Gregor, M.; Roch, T.; Satrapinskyy, L.; Moskova, A.; Mikula, M.; Kus, P.
2014-06-01
Low cost, low power and highly sensitive gas sensors operating at room temperature are very important devices for controlled hydrogen gas production and storage. One of the disadvantages of chemosensors is their high operating temperature (usually 200 - 400 °C), which excludes such type of sensors from usage in explosive environment. In this report, a new concept of gas chemosensors operating at room temperature based on TiO2 thin films is discussed. Integration of such sensor is fully compatible with sub-100 nm semiconductor technology and could be transferred directly from labor to commercial sphere.
Remotely deployable aerial inspection using tactile sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacLeod, C. N.; Cao, J.; Pierce, S. G.
For structural monitoring applications, the use of remotely deployable Non-Destructive Evaluation (NDE) inspection platforms offer many advantages, including improved accessibility, greater safety and reduced cost, when compared to traditional manual inspection techniques. The use of such platforms, previously reported by researchers at the University Strathclyde facilitates the potential for rapid scanning of large areas and volumes in hazardous locations. A common problem for both manual and remote deployment approaches lies in the intrinsic stand-off and surface coupling issues of typical NDE probes. The associated complications of these requirements are obviously significantly exacerbated when considering aerial based remote inspection and deployment,more » resulting in simple visual techniques being the preferred sensor payload. Researchers at Bristol Robotics Laboratory have developed biomimetic tactile sensors modelled on the facial whiskers (vibrissae) of animals such as rats and mice, with the latest sensors actively sweeping their tips across the surface in a back and forth motion. The current work reports on the design and performance of an aerial inspection platform and the suitability of tactile whisking sensors to aerial based surface monitoring applications.« less
A Reverse Localization Scheme for Underwater Acoustic Sensor Networks
Moradi, Marjan; Rezazadeh, Javad; Ismail, Abdul Samad
2012-01-01
Underwater Wireless Sensor Networks (UWSNs) provide new opportunities to observe and predict the behavior of aquatic environments. In some applications like target tracking or disaster prevention, sensed data is meaningless without location information. In this paper, we propose a novel 3D centralized, localization scheme for mobile underwater wireless sensor network, named Reverse Localization Scheme or RLS in short. RLS is an event-driven localization method triggered by detector sensors for launching localization process. RLS is suitable for surveillance applications that require very fast reactions to events and could report the location of the occurrence. In this method, mobile sensor nodes report the event toward the surface anchors as soon as they detect it. They do not require waiting to receive location information from anchors. Simulation results confirm that the proposed scheme improves the energy efficiency and reduces significantly localization response time with a proper level of accuracy in terms of mobility model of water currents. Major contributions of this method lie on reducing the numbers of message exchange for localization, saving the energy and decreasing the average localization response time. PMID:22666034
A reverse localization scheme for underwater acoustic sensor networks.
Moradi, Marjan; Rezazadeh, Javad; Ismail, Abdul Samad
2012-01-01
Underwater Wireless Sensor Networks (UWSNs) provide new opportunities to observe and predict the behavior of aquatic environments. In some applications like target tracking or disaster prevention, sensed data is meaningless without location information. In this paper, we propose a novel 3D centralized, localization scheme for mobile underwater wireless sensor network, named Reverse Localization Scheme or RLS in short. RLS is an event-driven localization method triggered by detector sensors for launching localization process. RLS is suitable for surveillance applications that require very fast reactions to events and could report the location of the occurrence. In this method, mobile sensor nodes report the event toward the surface anchors as soon as they detect it. They do not require waiting to receive location information from anchors. Simulation results confirm that the proposed scheme improves the energy efficiency and reduces significantly localization response time with a proper level of accuracy in terms of mobility model of water currents. Major contributions of this method lie on reducing the numbers of message exchange for localization, saving the energy and decreasing the average localization response time.
Energetic Materials Hazard Initiation: DoD Assessment Team Final Report
1987-05-05
which the Department of De - fense is now emphasizing (JROC, 1986). Although this aspect of hazards reduction primarily involves fielded systems and the...source of deficiency in the impact testing. Some efforts are reported in which phototransistors, IR sensors and/or pressure sensors are used to detect...Montgomery (1959), and Moore (1973). Recent research on the electrostatic discharge sensitivity of solid propellant samples was begun at Societe Nationale des
2012-07-01
does not display a currently valid OMB control number. 1. REPORT DATE JUL 2012 2 . REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE...bottom right). ............................................................... 5 Figure 3- 2 A standard approach to mitigating sensor positioning...within the yellow enclosure. ........................ 8 Figure 3-5 A comparison of the actual ( 2 -D motion, pen trace on paper) versus the computed
Payne, Jason; Woodward, Brenda K.; Storm, John B.
2009-01-01
The U.S. Geological Survey installed a network of pressure sensors at 65 sites along the Gulf Coast from Seadrift, Texas, northeast to Lake Charles, Louisiana, to record the timing, areal extent, and magnitude of inland storm surge and coastal flooding caused by Hurricane Ike in September 2008. A Global Positioning System was used to obtain elevations of reference marks near each sensor. A combination of real-time kinematic (RTK) and static Global Positioning System surveys were done to obtain elevations of reference marks. Leveling relative to reference marks was done to obtain elevations of sensor orifices above the reference marks. This report summarizes the Global Positioning System data collected and processed to obtain reference mark and storm-sensor-orifice elevations for 59 storm-surge sensors recovered from the original 65 installed as a necessary prelude to computation of storm-surge elevations. National Geodetic Survey benchmarks were used for RTK surveying. Where National Geodetic Survey benchmarks were not within 12 kilometers of a sensor site, static surveying was done. Additional control points for static surveying were in the form of newly established benchmarks or reestablished existing benchmarks. RTK surveying was used to obtain positions and elevations of reference marks for 29 sensor sites. Static surveying was used to obtain positions and elevations of reference marks for 34 sensor sites; four sites were surveyed using both methods. Multiple quality checks on the RTK-survey and static-survey data were applied. The results of all quality checks indicate that the desired elevation accuracy for the surveys of this report, less than 0.1-meter error, was achieved.
ShakeNet: a portable wireless sensor network for instrumenting large civil structures
Kohler, Monica D.; Hao, Shuai; Mishra, Nilesh; Govindan, Ramesh; Nigbor, Robert
2015-08-03
We report our findings from a U.S. Geological Survey (USGS) National Earthquake Hazards Reduction Program-funded project to develop and test a wireless, portable, strong-motion network of up to 40 triaxial accelerometers for structural health monitoring. The overall goal of the project was to record ambient vibrations for several days from USGS-instrumented structures. Structural health monitoring has important applications in fields like civil engineering and the study of earthquakes. The emergence of wireless sensor networks provides a promising means to such applications. However, while most wireless sensor networks are still in the experimentation stage, very few take into consideration the realistic earthquake engineering application requirements. To collect comprehensive data for structural health monitoring for civil engineers, high-resolution vibration sensors and sufficient sampling rates should be adopted, which makes it challenging for current wireless sensor network technology in the following ways: processing capabilities, storage limit, and communication bandwidth. The wireless sensor network has to meet expectations set by wired sensor devices prevalent in the structural health monitoring community. For this project, we built and tested an application-realistic, commercially based, portable, wireless sensor network called ShakeNet for instrumentation of large civil structures, especially for buildings, bridges, or dams after earthquakes. Two to three people can deploy ShakeNet sensors within hours after an earthquake to measure the structural response of the building or bridge during aftershocks. ShakeNet involved the development of a new sensing platform (ShakeBox) running a software suite for networking, data collection, and monitoring. Deployments reported here on a tall building and a large dam were real-world tests of ShakeNet operation, and helped to refine both hardware and software.
Thomas, Jason M; Chakraborty, Banani; Sen, Dipankar; Yu, Hua-Zhong
2012-08-22
A general approach is described for the de novo design and construction of aptamer-based electrochemical biosensors, for potentially any analyte of interest (ranging from small ligands to biological macromolecules). As a demonstration of the approach, we report the rapid development of a made-to-order electronic sensor for a newly reported early biomarker for lung cancer (CTAP III/NAP2). The steps include the in vitro selection and characterization of DNA aptamer sequences, design and biochemical testing of wholly DNA sensor constructs, and translation to a functional electrode-bound sensor format. The working principle of this distinct class of electronic biosensors is the enhancement of DNA-mediated charge transport in response to analyte binding. We first verify such analyte-responsive charge transport switching in solution, using biochemical methods; successful sensor variants were then immobilized on gold electrodes. We show that using these sensor-modified electrodes, CTAP III/NAP2 can be detected with both high specificity and sensitivity (K(d) ~1 nM) through a direct electrochemical reading. To investigate the underlying basis of analyte binding-induced conductivity switching, we carried out Förster Resonance Energy Transfer (FRET) experiments. The FRET data establish that analyte binding-induced conductivity switching in these sensors results from very subtle structural/conformational changes, rather than large scale, global folding events. The implications of this finding are discussed with respect to possible charge transport switching mechanisms in electrode-bound sensors. Overall, the approach we describe here represents a unique design principle for aptamer-based electrochemical sensors; its application should enable rapid, on-demand access to a class of portable biosensors that offer robust, inexpensive, and operationally simplified alternatives to conventional antibody-based immunoassays.
A molecular rotor based ratiometric sensor for basic amino acids.
Pettiwala, Aafrin M; Singh, Prabhat K
2018-01-05
The inevitable importance of basic amino acids, arginine and lysine, in human health and metabolism demands construction of efficient sensor systems for them. However, there are only limited reports on the 'ratiometric' detection of basic amino acids which is further restricted by the use of chemically complex sensor molecules, which impedes their prospect for practical applications. Herein, we report a ratiometric sensor system build on simple mechanism of disassociation of novel emissive Thioflavin-T H-aggregates from heparin surface, when subjected to interaction with basic amino acids. The strong and selective electrostatic and hydrogen bonding interaction of basic amino acids with heparin leads to large alteration in photophysical attributes of heparin bound Thioflavin-T, which forms a highly sensitive sensor platform for detection of basic amino acids in aqueous solution. These selective interactions between basic amino acids and heparin allow our sensor system to discriminate arginine and lysine from other amino acids. This unique mechanism of dissociation of Thioflavin-T aggregates from heparin surface provides ratiometric response on both fluorimetric and colorimetric outputs for detection of arginine and lysine, and thus it holds a significant advantage over other developed sensor systems which are restricted to single wavelength detection. Apart from the sensitivity and selectivity, our system also provides the advantage of simplicity, dual mode of sensing, and more importantly, it employs an inexpensive commercially available probe molecule, which is a significant advantage over other developed sensor systems that uses tedious synthesis protocol for the employed probe in the detection scheme, an impediment for practical applications. Additionally, our sensor system also shows response in complex biological media of serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Development of microsized slip sensors using dielectric elastomer for incipient slippage
NASA Astrophysics Data System (ADS)
Hwang, Do-Yeon; Kim, Baek-chul; Cho, Han-Jeong; Li, Zhengyuan; Lee, Youngkwan; Nam, Jae-Do; Moon, Hyungpil; Choi, Hyouk Ryeol; Koo, J. C.
2014-04-01
A humanoid robot hand has received significant attention in various fields of study. In terms of dexterous robot hand, slip detecting tactile sensor is essential to grasping objects safely. Moreover, slip sensor is useful in robotics and prosthetics to improve precise control during manipulation tasks. In this paper, sensor based-human biomimetic structure is fabricated. We reported a resistance tactile sensor that enables to detect a slip on the surface of sensor structure. The resistance slip sensor that the novel developed uses acrylonitrile-butadiene rubber (NBR) as a dielectric substrate and carbon particle as an electrode material. The presented sensor device in this paper has fingerprint-like structures that are similar with the role of the human's finger print. It is possible to measure the slip as the structure of sensor makes a deformation and it changes the resistance through forming a new conductive route. To verify effectiveness of the proposed slip detection, experiment using prototype of resistance slip sensor is conducted with an algorithm to detect slip and slip was successfully detected. In this paper, we will discuss the slip detection properties so four sensor and detection principle.
NASA Astrophysics Data System (ADS)
Zafar, Sufi; Lu, Minhua; Jagtiani, Ashish
2017-01-01
Field effect transistors (FET) have been widely used as transducers in electrochemical sensors for over 40 years. In this report, a FET transducer is compared with the recently proposed bipolar junction transistor (BJT) transducer. Measurements are performed on two chloride electrochemical sensors that are identical in all details except for the transducer device type. Comparative measurements show that the transducer choice significantly impacts the electrochemical sensor characteristics. Signal to noise ratio is 20 to 2 times greater for the BJT sensor. Sensitivity is also enhanced: BJT sensing signal changes by 10 times per pCl, whereas the FET signal changes by 8 or less times. Also, sensor calibration curves are impacted by the transducer choice. Unlike a FET sensor, the calibration curve of the BJT sensor is independent of applied voltages. Hence, a BJT sensor can make quantitative sensing measurements with minimal calibration requirements, an important characteristic for mobile sensing applications. As a demonstration for mobile applications, these BJT sensors are further investigated by measuring chloride levels in artificial human sweat for potential cystic fibrosis diagnostic use. In summary, the BJT device is demonstrated to be a superior transducer in comparison to a FET in an electrochemical sensor.
Zafar, Sufi; Lu, Minhua; Jagtiani, Ashish
2017-01-01
Field effect transistors (FET) have been widely used as transducers in electrochemical sensors for over 40 years. In this report, a FET transducer is compared with the recently proposed bipolar junction transistor (BJT) transducer. Measurements are performed on two chloride electrochemical sensors that are identical in all details except for the transducer device type. Comparative measurements show that the transducer choice significantly impacts the electrochemical sensor characteristics. Signal to noise ratio is 20 to 2 times greater for the BJT sensor. Sensitivity is also enhanced: BJT sensing signal changes by 10 times per pCl, whereas the FET signal changes by 8 or less times. Also, sensor calibration curves are impacted by the transducer choice. Unlike a FET sensor, the calibration curve of the BJT sensor is independent of applied voltages. Hence, a BJT sensor can make quantitative sensing measurements with minimal calibration requirements, an important characteristic for mobile sensing applications. As a demonstration for mobile applications, these BJT sensors are further investigated by measuring chloride levels in artificial human sweat for potential cystic fibrosis diagnostic use. In summary, the BJT device is demonstrated to be a superior transducer in comparison to a FET in an electrochemical sensor. PMID:28134275
3D printed stretchable capacitive sensors for highly sensitive tactile and electrochemical sensing
NASA Astrophysics Data System (ADS)
Li, Kai; Wei, Hong; Liu, Wenguang; Meng, Hong; Zhang, Peixin; Yan, Chaoyi
2018-05-01
Developments of innovative strategies for the fabrication of stretchable sensors are of crucial importance for their applications in wearable electronic systems. In this work, we report the successful fabrication of stretchable capacitive sensors using a novel 3D printing method for highly sensitive tactile and electrochemical sensing applications. Unlike conventional lithographic or templated methods, the programmable 3D printing technique can fabricate complex device structures in a cost-effective and facile manner. We designed and fabricated stretchable capacitive sensors with interdigital and double-vortex designs and demonstrated their successful applications as tactile and electrochemical sensors. Especially, our stretchable sensors exhibited a detection limit as low as 1 × 10-6 M for NaCl aqueous solution, which could have significant potential applications when integrated in electronics skins.
Commercial Sensory Survey Radiation Testing Progress Report
NASA Technical Reports Server (NTRS)
Becker, Heidi N.; Dolphic, Michael D.; Thorbourn, Dennis O.; Alexander, James W.; Salomon, Phil M.
2008-01-01
The NASA Electronic Parts and Packaging (NEPP) Program Sensor Technology Commercial Sensor Survey task is geared toward benefiting future NASA space missions with low-cost, short-duty-cycle, visible imaging needs. Such applications could include imaging for educational outreach purposes or short surveys of spacecraft, planetary, or lunar surfaces. Under the task, inexpensive commercial grade CMOS sensors were surveyed in fiscal year 2007 (FY07) and three sensors were selected for total ionizing dose (TID) and displacement damage dose (DDD) tolerance testing. The selected sensors had to meet selection criteria chosen to support small, low-mass cameras that produce good resolution color images. These criteria are discussed in detail in [1]. This document discusses the progress of radiation testing on the Micron and OmniVision sensors selected in FY07 for radiation tolerance testing.
Factors influencing the performance of G-quadruplex DNAzyme-based sensors.
Kong, De-Ming
2013-12-15
G-quadruplex DNAzymes are peroxidase-like complexes formed by nucleic acid G-quadruplexes and hemin. Compared with natural enzymes, G-quadruplex DNAzyme offers many advantages, thus making it a promising tool in the design of biosensors and chemical sensors. Many biosensors and chemical sensors based on G-quadruplex DNAzymes have been reported. A number of factors may affect the performance of G-quadruplex DNAzyme-based sensors. Here we focus on some aspects to be taken into account when designing a G-quadruplex DNAzyme-based sensor. These include the G-quadruplex-forming G-rich sequence, solution components, the reaction substrate, and enrichment strategy for G-quadruplex DNAzyme. We also provide an outlook for further research on G-quadruplex DNAzyme-based sensors. Copyright © 2013 Elsevier Inc. All rights reserved.
3D printed stretchable capacitive sensors for highly sensitive tactile and electrochemical sensing.
Li, Kai; Wei, Hong; Liu, Wenguang; Meng, Hong; Zhang, Peixin; Yan, Chaoyi
2018-05-04
Developments of innovative strategies for the fabrication of stretchable sensors are of crucial importance for their applications in wearable electronic systems. In this work, we report the successful fabrication of stretchable capacitive sensors using a novel 3D printing method for highly sensitive tactile and electrochemical sensing applications. Unlike conventional lithographic or templated methods, the programmable 3D printing technique can fabricate complex device structures in a cost-effective and facile manner. We designed and fabricated stretchable capacitive sensors with interdigital and double-vortex designs and demonstrated their successful applications as tactile and electrochemical sensors. Especially, our stretchable sensors exhibited a detection limit as low as 1 × 10 -6 M for NaCl aqueous solution, which could have significant potential applications when integrated in electronics skins.
Effects of rearview cameras and rear parking sensors on police-reported backing crashes.
Cicchino, Jessica B
2017-11-17
The objective of this study was to examine the effectiveness of rearview cameras, rear parking sensors, and both systems combined in preventing police-reported backing crashes. Negative binomial regression was used to compare rates of police-reported backing crash involvements per insured vehicle year in 22 U.S. states during 2009-2014 between passenger vehicle models with backing technologies and the same vehicle models where the optional systems were not purchased, controlling for other factors affecting crash risk. Rearview cameras were examined from four automakers, rear parking sensors from 2 automakers, and both systems combined from a single automaker. Rearview cameras reduced backing crash involvement rates by 17%. Reductions were larger for drivers 70 and older (36%) than for drivers younger than 70 (16%); however, estimates for older and younger drivers did not differ significantly from one another. The Buick Lucerne's rear parking sensor system reduced backing crash involvement rates significantly by 34%, but the reduction for Mercedes-Benz vehicles fit with a sensor system was small and not statistically significant. When averaged between the 2 automakers, effects were significantly larger for drivers 70 and older (38% reduction) than for drivers younger than 70 (1% increase); effects were significant for older but not younger drivers. Backing crash involvement rates were 13% lower among Mercedes-Benz vehicles with a rearview camera and parking sensors than among vehicles without, but this finding was not significant. Rearview cameras are effective in preventing police-reported backing crashes. Effects of rear parking sensors are less straightforward; it is unclear whether the Buick Lucerne system's benefits are due to the older age of its drivers, characteristics of the vehicle or system, or a combination. Systems may be especially beneficial to older drivers who might have limitations that make backing challenging. Although effect estimates did not differ significantly between older and younger drivers for both system types, the magnitude of the differences was large and the pattern of results was consistent across 6 of the 7 systems examined. When rear visibility systems become required equipment on new passenger vehicles in 2018, rearview cameras can be expected to prevent 1 in 6 backing crashes reported to police that involve equipped vehicles.
FogEye UV Sensor System evaluation : Phase III report.
DOT National Transportation Integrated Search
2002-11-01
FogEye technology offers the potential for operation of electro optical sensors and systems that function "hands-off", over extended distances during varying atmospheric conditions, day and night. The technology has been shown to employ solar blind u...
Biological Environmental Sampling Technologies Assessment
2015-12-01
unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT: U.S. Army Edgewood Chemical Biological Center, Research and Technology Directorate, BioSensors ...format (pdf) electronic version of this report: ECBC R&T Directorate, Biosciences Division, BioSensors Branch RDCB-DRB-S ATTN: Gostomski, J
Multi-sensor Navigation System Design
DOT National Transportation Integrated Search
1971-03-01
This report treats the design of naviggation systems that collect data from two or more on-board measurement subsystems and precess this data in an on-board computer. Such systems are called Multi-sensor Navigation Systems. : The design begins with t...
TECHNOLOGY EVALUATION REPORT, HYDROTECHNICS IN SITU FLOW SENSOR
The U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program evaluated performance of HydroTechnics, Inc. flow sensors in measuring the three-dimensional flow pattern created by operation of the Wasatch Environmental, Inc. (WEI) ground...
Pemberton, Roy M.; Cox, Timothy; Tuffin, Rachel; Drago, Guido A.; Griffiths, John; Pittson, Robin; Johnson, Graham; Xu, Jinsheng; Sage, Ian C.; Davies, Rhodri; Jackson, Simon K.; Kenna, Gerry; Luxton, Richard; Hart, John P.
2014-01-01
This report describes the design and development of an integrated electrochemical cell culture monitoring system, based on enzyme-biosensors and chemical sensors, for monitoring indicators of mammalian cell metabolic status. MEMS technology was used to fabricate a microwell-format silicon platform including a thermometer, onto which chemical sensors (pH, O2) and screen-printed biosensors (glucose, lactate), were grafted/deposited. Microwells were formed over the fabricated sensors to give 5-well sensor strips which were interfaced with a multipotentiostat via a bespoke connector box interface. The operation of each sensor/biosensor type was examined individually, and examples of operating devices in five microwells in parallel, in either potentiometric (pH sensing) or amperometric (glucose biosensing) mode are shown. The performance characteristics of the sensors/biosensors indicate that the system could readily be applied to cell culture/toxicity studies. PMID:25360580
Evaluation of taste solutions by sensor fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kojima, Yohichiro; Sato, Eriko; Atobe, Masahiko
In our previous studies, properties of taste solutions were discriminated based on sound velocity and amplitude of ultrasonic waves propagating through the solutions. However, to make this method applicable to beverages which contain many taste substances, further studies are required. In this study, the waveform of an ultrasonic wave with frequency of approximately 5 MHz propagating through a solution was measured and subjected to frequency analysis. Further, taste sensors require various techniques of sensor fusion to effectively obtain chemical and physical parameter of taste solutions. A sensor fusion method of ultrasonic wave sensor and various sensors, such as the surfacemore » plasmon resonance (SPR) sensor, to estimate tastes were proposed and examined in this report. As a result, differences among pure water and two basic taste solutions were clearly observed as differences in their properties. Furthermore, a self-organizing neural network was applied to obtained data which were used to clarify the differences among solutions.« less
Lab-on-a-chip sensor for measuring Zn by stripping voltammetry
NASA Astrophysics Data System (ADS)
Pei, Xing; Kang, Wenjing; Yue, Wei; Bange, Adam; Wong, Hector R.; Heineman, William R.; Papautsky, Ian
2012-03-01
This work reports on continuing development of a lab-on-a-chip sensor for electrochemical detection of heavy metal zinc in blood serum. The sensor consists of a three electrode system, including an environmentally-friendly bismuth working electrode, a Ag/AgCl reference electrode, and a gold auxiliary electrode. By optimizing the electrodeposition of bismuth film, better control of fabrication steps and improving interface between the sensor and potentiostat, repeatability and sensitivity of the lab-on-a-chip sensor has been improved. Through optimization of electrolyte and stripping voltammetry parameters, limits of detection were greatly improved. The optimized sensor was able to measure zinc in in the physiological range of 65-95 μg/dL. Ultimately, with further development and integrated sample preparation sensor system will permit rapid (min) measurements of zinc from a sub-mL sample (a few drops of blood) for bedside monitoring.
Tattoolike Polyaniline Microparticle-Doped Gold Nanowire Patches as Highly Durable Wearable Sensors.
Gong, Shu; Lai, Daniel T H; Wang, Yan; Yap, Lim Wei; Si, Kae Jye; Shi, Qianqian; Jason, Naveen Noah; Sridhar, Tam; Uddin, Hemayet; Cheng, Wenlong
2015-09-09
Wearable and highly sensitive strain sensors are essential components of electronic skin for future biomonitoring and human machine interfaces. Here we report a low-cost yet efficient strategy to dope polyaniline microparticles into gold nanowire (AuNW) films, leading to 10 times enhancement in conductivity and ∼8 times improvement in sensitivity. Simultaneously, tattoolike wearable sensors could be fabricated simply by a direct "draw-on" strategy with a Chinese penbrush. The stretchability of the sensors could be enhanced from 99.7% to 149.6% by designing curved tattoo with different radius of curvatures. We also demonstrated roller coating method to encapusulate AuNWs sensors, exhibiting excellent water resistibility and durability. Because of improved conductivity of our sensors, they can directly interface with existing wireless circuitry, allowing for fabrication of wireless flexion sensors for a human finger-controlled robotic arm system.
Triaxial fiber optic magnetic field sensor for MRI applications
NASA Astrophysics Data System (ADS)
Filograno, Massimo L.; Pisco, Marco; Catalano, Angelo; Forte, Ernesto; Aiello, Marco; Soricelli, Andrea; Davino, Daniele; Visone, Ciro; Cutolo, Antonello; Cusano, Andrea
2016-05-01
In this paper, we report a fiber-optic triaxial magnetic field sensor, based on Fiber Bragg Gratings (FBGs) integrated with giant magnetostrictive material, the Terfenol-D. The realized sensor has been designed and engineered for Magnetic Resonance Imaging (MRI) applications. A full magneto-optical characterization of the triaxial sensing probe has been carried out, providing the complex relationship among the FBGs wavelength shift and the applied magnetostatic field vector. Finally, the developed fiber optic sensors have been arranged in a sensor network composed of 20 triaxial sensors for mapping the magnetic field distribution in a MRI-room at a diagnostic center in Naples (SDN), equipped with Positron emission tomography/magnetic resonance (PET/MR) instrumentation. Experimental results reveal that the proposed sensor network can be efficiently used in MRI centers for performing quality assurance tests, paving the way for novel integrated tools to measure the magnetic dose accumulated day by day by MRI operators.
Holographic detection of hydrocarbon gases and other volatile organic compounds.
Martínez-Hurtado, J L; Davidson, C A B; Blyth, J; Lowe, C R
2010-10-05
There is a need to develop sensors for real-time monitoring of volatile organic compounds (VOCs) and hydrocarbon gases in both external and indoor environments, since these compounds are of growing concern in human health and welfare. Current measurement technology for VOCs requires sophisticated equipment and lacks the prospect for rapid real-time monitoring. Holographic sensors can give a direct reading of the analyte concentration as a color change. We report a technique for recording holographic sensors by laser ablation of silver particles formed in situ by diffusion. This technique allows a readily available hydrophobic silicone elastomer to be transformed into an effective sensor for hydrocarbon gases and other volatile compounds. The intermolecular interactions present between the polymer and molecules are used to predict the sensor performance. The hydrophobicity of this material allows the sensor to operate without interference from water and other atmospheric gases and thus makes the sensor suitable for biomedical, industrial, or environmental analysis.
Piezoresistive Sensor with High Elasticity Based on 3D Hybrid Network of Sponge@CNTs@Ag NPs.
Zhang, Hui; Liu, Nishuang; Shi, Yuling; Liu, Weijie; Yue, Yang; Wang, Siliang; Ma, Yanan; Wen, Li; Li, Luying; Long, Fei; Zou, Zhengguang; Gao, Yihua
2016-08-31
Pressure sensors with high elasticity are in great demand for the realization of intelligent sensing, but there is a need to develope a simple, inexpensive, and scalable method for the manufacture of the sensors. Here, we reported an efficient, simple, facile, and repeatable "dipping and coating" process to manufacture a piezoresistive sensor with high elasticity, based on homogeneous 3D hybrid network of carbon nanotubes@silver nanoparticles (CNTs@Ag NPs) anchored on a skeleton sponge. Highly elastic, sensitive, and wearable sensors are obtained using the porous structure of sponge and the synergy effect of CNTs/Ag NPs. Our sensor was also tested for over 2000 compression-release cycles, exhibiting excellent elasticity and cycling stability. Sensors with high performance and a simple fabrication process are promising devices for commercial production in various electronic devices, for example, sport performance monitoring and man-machine interfaces.
Liu, Bing-Hong; Jiang, Yong-Xiang; Zhu, Xiao-Song; Tang, Xiao-Li; Shi, Yi-Wei
2013-12-30
A new kind of surface plasmon resonance (SPR) sensor based on silver-coated hollow fiber (HF) structure for the detection of liquids with high refractive index (RI) is presented. Liquid sensed medium with high RI is filled in the hollow core of the HF and its RI can be detected by measuring the transmission spectra of the HF SPR sensor. The designed sensors with different silver thicknesses are fabricated and the transmission spectra for filled liquids with different RI are measured to investigate the performances of the sensors. Theoretical analysis is also carried out to evaluate the performance. The simulation results agree well with the experimental results. Factors that might affect sensitivity and detection accuracy of the sensor are discussed. The highest sensitivity achieved is 6,607 nm/RIU, which is comparable to the sensitivities of the other reported fiber SPR sensors.
The world's microbiology laboratories can be a global microbial sensor network.
O'Brien, Thomas F; Stelling, John
2014-04-01
The microbes that infect us spread in global and local epidemics, and the resistance genes that block their treatment spread within and between them. All we can know about where they are to track and contain them comes from the only places that can see them, the world's microbiology laboratories, but most report each patient's microbe only to that patient's caregiver. Sensors, ranging from instruments to birdwatchers, are now being linked in electronic networks to monitor and interpret algorithmically in real-time ocean currents, atmospheric carbon, supply-chain inventory, bird migration, etc. To so link the world's microbiology laboratories as exquisite sensors in a truly lifesaving real-time network their data must be accessed and fully subtyped. Microbiology laboratories put individual reports into inaccessible paper or mutually incompatible electronic reporting systems, but those from more than 2,200 laboratories in more than 108 countries worldwide are now accessed and translated into compatible WHONET files. These increasingly web-based files could initiate a global microbial sensor network. Unused microbiology laboratory byproduct data, now from drug susceptibility and biochemical testing but increasingly from new technologies (genotyping, MALDI-TOF, etc.), can be reused to subtype microbes of each genus/species into sub-groupings that are discriminated and traced with greater sensitivity. Ongoing statistical delineation of subtypes from global sensor network data will improve detection of movement into any patient of a microbe or resistance gene from another patient, medical center or country. Growing data on clinical manifestations and global distributions of subtypes can automate comments for patient's reports, select microbes to genotype and alert responders.
Autonomous Adaptation and Collaboration of Unmanned Vehicles for Tracking Submerged Contacts
2012-06-01
filter: CRS RANGE REPORT =”name=archie,range=23.4,target= jackal ,time=2342551.213” • Line 8: ping wait is the time delay between range pulses. • Line 13: rn...uFldContactRangeSensor Settings 1: ProcessConfig = uFldContactRangeSensor 2: { 3: AppTick = 4 4: CommsTick = 4 5: 6: reply distance = jackal = 50 7: reach distance...REPORT = CRS RANGE REPORT 8: MY SHIP = archie 9: MY FRIEND = betty 10: MY CONTACT = jackal 11: MY BEST GUESS = besttarget 12: MY AVG GUESS = avgtarget 13
Development and Evaluation of a Smartphone-Based Measure of Social Rhythms for Bipolar Disorder.
Matthews, Mark; Abdullah, Saeed; Murnane, Elizabeth; Voida, Stephen; Choudhury, Tanzeem; Gay, Geri; Frank, Ellen
2016-08-01
Dynamic psychological processes are most often assessed using self-report instruments. This places a constraint on how often and for how long data can be collected due to the burden placed on human participants. Smartphones are ubiquitous and highly personal devices, equipped with sensors that offer an opportunity to measure and understand psychological processes in real-world contexts over the long term. In this article, we present a novel smartphone approach to address the limitations of self-report in bipolar disorder where mood and activity are key constructs. We describe the development of MoodRhythm, a smartphone application that incorporates existing self-report elements from interpersonal and social rhythm therapy, a clinically validated treatment, and combines them with novel inputs from smartphone sensors. We reflect on lessons learned in transitioning from an existing self-report instrument to one that involves smartphone sensors and discuss the potential impact of these changes on the future of psychological assessment.
Application of fiber-Bragg-grating-based strain sensors for civil infrastructure health monitoring
NASA Astrophysics Data System (ADS)
Tjin, Swee C.; Rupali, S.; Moyo, Pilate; Brownjohn, James M. W.; Ngo, Nam Quoc
2003-10-01
Over past few years, the concept of structural health monitoring has been emerging as a new area of research. Fiber Bragg grating (FBG) based sensor offers a new sensing approach with a number of advantages over conventional sensors. This new sensing technology is suitable for the harsh environment of construction industry due to its robustness, ruggedness and ease of installation. Two unique advantages of FBG based sensors are immunity to electromagnetic interference and multiplexing capability. This paper reports some of the results of a multi-disciplinary program on the FBG based sensors involving the School of Electrical and Electronic Engineering and the School of Civil and Environment Engineering at Nanyang Technological University, Singapore.
Understanding the Potential of WO₃ Based Sensors for Breath Analysis.
Staerz, Anna; Weimar, Udo; Barsan, Nicolae
2016-10-29
Tungsten trioxide is the second most commonly used semiconducting metal oxide in gas sensors. Semiconducting metal oxide (SMOX)-based sensors are small, robust, inexpensive and sensitive, making them highly attractive for handheld portable medical diagnostic detectors. WO₃ is reported to show high sensor responses to several biomarkers found in breath, e.g., acetone, ammonia, carbon monoxide, hydrogen sulfide, toluene, and nitric oxide. Modern material science allows WO₃ samples to be tailored to address certain sensing needs. Utilizing recent advances in breath sampling it will be possible in the future to test WO₃-based sensors in application conditions and to compare the sensing results to those obtained using more expensive analytical methods.
NASA Astrophysics Data System (ADS)
Jang, Hani; Kim, Minki; Kim, Yongjun
2016-12-01
This paper reports on a semiconductor gas sensor array to detect nitrogen oxides (NOx) in automotive exhaust gas. The proposed semiconductor gas sensor array consisted of one common electrode and three individual electrodes to minimize the size of the sensor array, and three sensing layers [TiO2 + SnO2 (15 wt%), SnO2, and Ga2O3] were deposited using screen printing. In addition, sensing materials were sintered under the same conditions in order to take advantage of batch processing. The sensing properties of the proposed sensor array were verified by experimental measurements, and the selectivity improved by using pattern recognition.
Understanding the Potential of WO3 Based Sensors for Breath Analysis
Staerz, Anna; Weimar, Udo; Barsan, Nicolae
2016-01-01
Tungsten trioxide is the second most commonly used semiconducting metal oxide in gas sensors. Semiconducting metal oxide (SMOX)-based sensors are small, robust, inexpensive and sensitive, making them highly attractive for handheld portable medical diagnostic detectors. WO3 is reported to show high sensor responses to several biomarkers found in breath, e.g., acetone, ammonia, carbon monoxide, hydrogen sulfide, toluene, and nitric oxide. Modern material science allows WO3 samples to be tailored to address certain sensing needs. Utilizing recent advances in breath sampling it will be possible in the future to test WO3-based sensors in application conditions and to compare the sensing results to those obtained using more expensive analytical methods. PMID:27801881
Sebastián, Eduardo; Armiens, Carlos; Gómez-Elvira, Javier; Zorzano, María P; Martinez-Frias, Jesus; Esteban, Blanca; Ramos, Miguel
2010-01-01
We describe the parameters that drive the design and modeling of the Rover Environmental Monitoring Station (REMS) Ground Temperature Sensor (GTS), an instrument aboard NASA's Mars Science Laboratory, and report preliminary test results. REMS GTS is a lightweight, low-power, and low cost pyrometer for measuring the Martian surface kinematic temperature. The sensor's main feature is its innovative design, based on a simple mechanical structure with no moving parts. It includes an in-flight calibration system that permits sensor recalibration when sensor sensitivity has been degraded by deposition of dust over the optics. This paper provides the first results of a GTS engineering model working in a Martian-like, extreme environment.
Semiconductor metal oxide compounds based gas sensors: A literature review
NASA Astrophysics Data System (ADS)
Patil, Sunil Jagannath; Patil, Arun Vithal; Dighavkar, Chandrakant Govindrao; Thakare, Kashinath Shravan; Borase, Ratan Yadav; Nandre, Sachin Jayaram; Deshpande, Nishad Gopal; Ahire, Rajendra Ramdas
2015-03-01
This paper gives a statistical view about important contributions and advances on semiconductor metal oxide (SMO) compounds based gas sensors developed to detect the air pollutants such as liquefied petroleum gas (LPG), H2S, NH3, CO2, acetone, ethanol, other volatile compounds and hazardous gases. Moreover, it is revealed that the alloy/composite made up of SMO gas sensors show better gas response than their counterpart single component gas sensors, i.e., they are found to enhance the 4S characteristics namely speed, sensitivity, selectivity and stability. Improvement of such types of sensors used for detection of various air pollutants, which are reported in last two decades, is highlighted herein.
A New Multi-Sensor Track Fusion Architecture for Multi-Sensor Information Integration
2004-09-01
NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION ...NAME(S) AND ADDRESS(ES) Lockheed Martin Aeronautical Systems Company,Marietta,GA,3063 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING...tracking process and degrades the track accuracy. ARCHITECHTURE OF MULTI-SENSOR TRACK FUSION MODEL The Alpha
Meteorological Sensor Array (MSA)-Phase I. Volume 3 (Pre-Field Campaign Sensor Calibration)
2015-07-01
turbulence impact of the WSMR solar array. 4) Designing , developing, testing , and evaluating integrated Data Acquisition System (DAS) hardware and...ARL-TR-7362 ● JULY 2015 US Army Research Laboratory Meteorological Sensor Array (MSA)–Phase I, Volume 3 (Pre-Field Campaign...NOTICES Disclaimers The findings in this report are not to be construed as an official Department of the Army position unless so designated by
United States Air Force Summer Faculty Research Program. Management Report. Volume 1
1988-12-01
sensors , measure reaction characteristics of fuel and oxidizer at various inlet velocities and initial conditions. Application of spectroscopy, high... applications in armament systems. False signals caused by cloud, fog, and snow interfere with proper response of the sensors , and efforts to... sensor for this application have not been fully successful (1-18). Presence of dense clouds, fog, or snow will create false signals and will obscure
Revolutionize Situational Awareness in Emergencies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hehlen, Markus Peter
This report describes an integrated system that provides real-time actionable information to first responders. LANL will integrate three technologies to form an advanced predictive real-time sensor network including compact chemical and wind sensor sin low cost rugged package for outdoor installation; flexible robust communication architecture linking sensors in near-real time to globally accessible servers; and the QUIC code which predicts contamination transport and dispersal in urban environments in near real time.
University of Pennsylvania MAGIC 2010 Final Report
2011-01-10
and mapping ( SLAM ) techniques are employed to build a local map of the environment surrounding the robot. Readings from the two complementary LIDAR sen...IMU, LIDAR , Cameras Localization Disrupter UGV Local Navigation Sensors: GPS, IMU, LIDAR , Cameras Laser Control Localization Task Planner Strategy/Plan...various components shown in Figure 2. This is comprised of the following subsystems: • Sensor UGV: Mobile UGVs with LIDAR and camera sensors, GPS, and
Validation Test Report for the Automated Optical Processing System (AOPS) Version 4.10
2015-08-25
Geostationary Ocean Color Imager (GOCI) sensors. AOPS enables exploitation of multiple space-borne ocean color satellite sensors to provide optical...package as well as from the Geostationary Ocean Color Imager (GOCI) sensor aboard the Communication Ocean and Meteorological Satellite (COMS) satellite... GEOstationary Coastal and Air Pollution Events (GEO-CAPE) mission and provided to NRL courtesy of Mike Ondrusek and Zhongping Lee. AOP and IOP data were
Acoustic Vector-Sensor Array Processing
2010-06-01
NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) Massachusetts Institute...ADDRESS( ES ) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public...section shows, vector-sensor arrays are more versatile than arrays of only pressure-sensors. Exploiting this versatility raises a number of ques
Electronic Master Monitor and Advisory Display System, Human Engineering Summary Report.
1981-06-01
Communications, Sensors Instrumentation Division IS. NUMBER OF PAGES Fort Monmouth, NJ 0770M 226 14. MONITORING AGENCY NAME & ADORESS{I1 differel from...quantized each indication according to electrical signal, sensor type, display type, operating ranges, etc. The HFE evaluation sought to categorize the...was based on: " Frequency of the suggestion across crews * Relative potential for reducing workload " The need for sophisticated sensors for
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steven Buckley; Reza Gharavi; Marco Leon
The overall goal of this project has been to develop a highly sensitive, multiplexed TDL-based sensor for CO{sub 2}, CO, H{sub 2}O (and temperature), CH{sub 4}, H{sub 2}S, and NH{sub 3}. Such a sensor was designed with so-called 'plug-and-play' characteristics to accommodate additional sensors, and provided in situ path-integrated measurements indicative of average concentrations at speeds suitable for direct gasifier control. The project developed the sensor and culminated in a real-world test of the underlying technology behind the sensor. During the project, new underlying measurements of spectroscopic constants for all of the gases of interest performed, in custom cells builtmore » for the project. The envisioned instrument was built from scratch from component lasers, fiber optics, amplifier blocks, detectors, etc. The sensor was tested for nearly a week in an operational power plant. The products of this research are expected to have a direct impact on gasifier technology and the production of high-quality syngas, with substantial broader application to coal and other energy systems. This report is the final technical report on project DE-FG26-04NT42172. During the project we completed all of the milestones planned in the project, with a modification of milestone (7) required due to lack of funding and personnel.« less
Song, Fang; Zheng, Chuantao; Yan, Wanhong; Ye, Weilin; Wang, Yiding; Tittel, Frank K
2017-12-11
To suppress sensor noise with unknown statistical properties, a novel self-adaptive direct laser absorption spectroscopy (SA-DLAS) technique was proposed by incorporating a recursive, least square (RLS) self-adaptive denoising (SAD) algorithm and a 3291 nm interband cascade laser (ICL) for methane (CH 4 ) detection. Background noise was suppressed by introducing an electrical-domain noise-channel and an expectation-known-based RLS SAD algorithm. Numerical simulations and measurements were carried out to validate the function of the SA-DLAS technique by imposing low-frequency, high-frequency, White-Gaussian and hybrid noise on the ICL scan signal. Sensor calibration, stability test and dynamic response measurement were performed for the SA-DLAS sensor using standard or diluted CH 4 samples. With the intrinsic sensor noise considered only, an Allan deviation of ~43.9 ppbv with a ~6 s averaging time was obtained and it was further decreased to 6.3 ppbv with a ~240 s averaging time, through the use of self-adaptive filtering (SAF). The reported SA-DLAS technique shows enhanced sensitivity compared to a DLAS sensor using a traditional sensing architecture and filtering method. Indoor and outdoor atmospheric CH 4 measurements were conducted to validate the normal operation of the reported SA-DLAS technique.
A new aptameric biosensor for cocaine based on surface-enhanced Raman scattering spectroscopy.
Chen, Jiwei; Jiang, Jianhui; Gao, Xing; Liu, Guokun; Shen, Guoli; Yu, Ruqin
2008-01-01
The present study reports the proof of principle of a reagentless aptameric sensor based on surface-enhanced Raman scattering (SERS) spectroscopy with "signal-on" architecture using a model target of cocaine. This new aptameric sensor is based on the conformational change of the surface-tethered aptamer on a binding target that draws a certain Raman reporter in close proximity to the SERS substrate, thereby increasing the Raman scattering signal due to the local enhancement effect of SERS. To improve the response performance, the sensor is fabricated from a cocaine-templated mixed self-assembly of a 3'-terminal tetramethylrhodamine (TMR)-labeled DNA aptamer on a silver colloid film by means of an alkanethiol moiety at the 5' end. This immobilization strategy optimizes the orientation of the aptamer on the surface and facilitates the folding on the binding target. Under optimized assay conditions, one can determine cocaine at a concentration of 1 muM, which compares favorably with analogous aptameric sensors based on electrochemical and fluorescence techniques. The sensor can be readily regenerated by being washed with a buffer. These results suggest that the SERS-based transducer might create a new dimension for future development of aptameric sensors for sensitive determination in biochemical and biomedical studies.
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; ...
2016-01-27
We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanicallymore » flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.« less
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin
We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanicallymore » flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.« less
In Vivo Detection of Reactive Oxygen Species and Redox Status in Caenorhabditis elegans.
Braeckman, Bart P; Smolders, Arne; Back, Patricia; De Henau, Sasha
2016-10-01
Due to its large families of redox-active enzymes, genetic amenability, and complete transparency, the nematode Caenorhabditis elegans has the potential to become an important model for the in vivo study of redox biology. The recent development of several genetically encoded ratiometric reactive oxygen species (ROS) and redox sensors has revolutionized the quantification and precise localization of ROS and redox signals in living organisms. Only few exploratory studies have applied these sensors in C. elegans and undoubtedly much remains to be discovered in this model. As a follow-up to our recent findings that the C. elegans somatic gonad uses superoxide and hydrogen peroxide (H2O2) signals to communicate with the germline, we here analyze the patterns of H2O2 inside the C. elegans germline. Despite the advantages of genetically encoded ROS and redox sensors over classic chemical sensors, still several general as well as C. elegans-specific issues need to be addressed. The major concerns for the application of these sensors in C. elegans are (i) decreased vitality of some reporter strains, (ii) interference of autofluorescent compartments with the sensor signal, and (iii) the use of immobilization methods that do not influence the worm's redox physiology. We propose that several of the current issues may be solved by designing reporter strains carrying single copies of codon-optimized sensors. Preferably, these sensors should have their emission wavelengths in the red region, where autofluorescence is absent. Worm analysis could be optimized using four-dimensional ratiometric fluorescence microscopy of worms immobilized in microfluidic chips. Antioxid. Redox Signal. 25, 577-592.
Almeida, Fabrício; Brennan, Michael; Joseph, Phillip; Whitfield, Stuart; Dray, Simon; Paschoalini, Amarildo
2014-03-20
Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.
Susceptibility of interstitial continuous glucose monitor performance to sleeping position.
Mensh, Brett D; Wisniewski, Natalie A; Neil, Brian M; Burnett, Daniel R
2013-07-01
Developing a round-the-clock artificial pancreas requires accurate and stable continuous glucose monitoring. The most widely used continuous glucose monitors (CGMs) are percutaneous, with the sensor residing in the interstitial space. Inaccuracies in percutaneous CGM readings during periods of lying on the devices (e.g., in various sleeping positions) have been anecdotally reported but not systematically studied. In order to assess the impact of sleep and sleep position on CGM performance, we conducted a study in human subjects in which we measured the variability of interstitial CGM data at night as a function of sleeping position. Commercially available sensors were placed for 4 days in the abdominal subcutaneous tissue in healthy, nondiabetic volunteers (four sensors per person, two per side). Nocturnal sleeping position was determined from video recordings and correlated to sensor data. We observed that, although the median of the four sensor readings was typically 70-110 mg/dl during sleep, individual sensors intermittently exhibited aberrant glucose readings (>25 mg/dl away from median) and that these aberrant readings were strongly correlated with subjects lying on the sensors. We expected and observed that most of these aberrant sleep-position-related CGM readings were sudden decreases in reported glucose values, presumably due to local blood-flow decreases caused by tissue compression. Curiously, in rare cases, the aberrant CGM readings were elevated values. These findings highlight limitations in our understanding of interstitial fluid physiology in the subcutaneous space and have significant implications for the utilization of sensors in the construction of an artificial pancreas. © 2013 Diabetes Technology Society.
Almeida, Fabrício; Brennan, Michael; Joseph, Phillip; Whitfield, Stuart; Dray, Simon; Paschoalini, Amarildo
2014-01-01
Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors. PMID:24658622
Microbial BOD sensors based on Zr (IV)-loaded collagen fiber.
Zhao, Lei; He, Li; Chen, Shujuan; Zou, Likou; Zhou, Kang; Ao, Xiaolin; Liu, Shuliang; Hu, Xinjie; Han, Guoquan
2017-03-01
Biochemical oxygen demand (BOD) sensors based on Zr (IV)-loaded collagen fiber (ZrCF), a novel material with great porous structure, were developed. This novel material shows adsorbability by microorganisms. Saccharomyces cerevisiae and Escherichia coli were used for the construction of BOD sensors. Factors affecting BOD sensor performance were examined. The ZrCF-based BOD sensor showed different sensitivities and linear response ranges with different biofilm densities. The amount of microorganisms strongly affected the performance of the BOD sensor. Poor permeability of previously reported immobilization carriers were greatly circumvented by ZrCF. The service life of the ZrCF-based BOD sensor was more than 42 days. The immobilized microorganisms can be stored for more than 6 months under 4°C in PB solution. There was good correlation between the results of the sensor method and the standard 5-day BOD method in the determination of pure organic substrates and real water samples. Copyright © 2016 Elsevier Inc. All rights reserved.
Study of robust thin film PT-1000 temperature sensors for cryogenic process control applications
NASA Astrophysics Data System (ADS)
Ramalingam, R.; Boguhn, D.; Fillinger, H.; Schlachter, S. I.; Süßer, M.
2014-01-01
In some cryogenic process measurement applications, for example, in hydrogen technology and in high temperature superconductor based generators, there is a need of robust temperature sensors. These sensors should be able to measure the large temperature range of 20 - 500 K with reasonable resolution and accuracy. Thin film PT 1000 sensors could be a choice to cover this large temperature range. Twenty one sensors selected from the same production batch were tested for their temperature sensitivity which was then compared with different batch sensors. Furthermore, the sensor's stability was studied by subjecting the sensors to repeated temperature cycles of 78-525 K. Deviations in the resistance were investigated using ice point calibration and water triple point calibration methods. Also the study of directional oriented intense static magnetic field effects up to 8 Oersted (Oe) were conducted to understand its magneto resistance behaviour in the cryogenic temperature range from 77 K - 15 K. This paper reports all investigation results in detail.
Proceedings of a U.S. Geological Survey pressure-sensor Workshop, Denver, Colorado, July 28-31, 1992
Wilbourn, Sammy L.
1994-01-01
The U.S. Geological Survey (USGS) conducted a Pressure Sensor Workshop, oriented toward the measurement of stage in surface waters, in Denver, Colorado, July 28-31, 1992. Twenty attendees from the U.S. Geological Survey and the National Oceanic and Atmospheric Administration gave presentations concerning their experiences with the use of pressure sensors in hydrologic investigations. This report is a compilation of the abstracts of the presentations made at the workshop. Workshop participants concluded that each of the sensors evaluated by the U.S. Geological Survey has strengths and weaknesses. Personnel contemplating the use of pressure sensors discussed at this workshop should contact workshop attendees and consult with them about their experiences with those sensors. The attendees preferred to use stilling wells with float-operated water-level sensors as the primary means for monitoring water levels. However, pressure sensor systems were favored as replacements for mercury manometers and as alternatives to stilling wells at sites where stilling wells are not practical or cost effective.
A Tactile Sensor Using Piezoresistive Beams for Detection of the Coefficient of Static Friction
Okatani, Taiyu; Takahashi, Hidetoshi; Noda, Kentaro; Takahata, Tomoyuki; Matsumoto, Kiyoshi; Shimoyama, Isao
2016-01-01
This paper reports on a tactile sensor using piezoresistive beams for detection of the coefficient of static friction merely by pressing the sensor against an object. The sensor chip is composed of three pairs of piezoresistive beams arranged in parallel and embedded in an elastomer; this sensor is able to measure the vertical and lateral strains of the elastomer. The coefficient of static friction is estimated from the ratio of the fractional resistance changes corresponding to the sensing elements of vertical and lateral strains when the sensor is in contact with an object surface. We applied a normal force on the sensor surface through objects with coefficients of static friction ranging from 0.2 to 1.1. The fractional resistance changes corresponding to vertical and lateral strains were proportional to the applied force. Furthermore, the relationship between these responses changed according to the coefficients of static friction. The experimental result indicated the proposed sensor could determine the coefficient of static friction before a global slip occurs. PMID:27213374
Tasaltin, Cihat; Ebeoglu, Mehmet Ali; Ozturk, Zafer Ziya
2012-01-01
In this study, zinc oxide (ZnO) was a very good candidate for improving the sensitivity of gas sensor technology. The preparation of an electrospun ZnO nanostructured thin film on a 433 MHz Rayleigh wave based Surface Acoustic Wave (SAW) sensor and the investigation of the acoustoelectric effect on the responses of the SAW sensor are reported. We prepared an electrospun ZnO nanostructured thin film on the SAW devices by using an electrospray technique. To investigate the dependency of the sensor response on the structure and the number of the ZnO nanoparticles, SAW sensors were prepared with different coating loads. The coating frequency shifts were adjusted to fall between 100 kHz and 2.4 MHz. The sensor measurements were performed against VOCs such as acetone, trichloroethylene, chloroform, ethanol, n-propanol and methanol vapor. The sensor responses of n-propanol have opposite characteristics to the other VOCs, and we attributed these characteristics to the elastic effect/acoustoelectric effect.
Continued Development of Compact Multi-gas Monitor for Life Support Systems Control in Space
NASA Technical Reports Server (NTRS)
Delgado-Alonso, Jesús; Phillips, Straun; Chullen, Cinda; Quinn, Gregory
2016-01-01
Miniature optic gas sensors (MOGS) based on luminescent materials have shown great potential as alternatives to Near-Infrared-based gas sensor systems for the advanced space suit portable life support system (PLSS). The unique capability of MOGS for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of MOGS humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages of MOGS over both traditional and advanced Non-Dispersive Infrared (NDIR) gas sensors, which have shown so far longer life than luminescent sensors. This paper presents the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted at Intelligent Optical Systems laboratories, a United Technology Corporation Aerospace Systems (UTAS) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems and the advantages and limitations found through detailed sensor validation are discussed.
An Annular Mechanical Temperature Compensation Structure for Gas-Sealed Capacitive Pressure Sensor
Hao, Xiuchun; Jiang, Yonggang; Takao, Hidekuni; Maenaka, Kazusuke; Higuchi, Kohei
2012-01-01
A novel gas-sealed capacitive pressure sensor with a temperature compensation structure is reported. The pressure sensor is sealed by Au-Au diffusion bonding under a nitrogen ambient with a pressure of 100 kPa and integrated with a platinum resistor-based temperature sensor for human activity monitoring applications. The capacitance-pressure and capacitance-temperature characteristics of the gas-sealed capacitive pressure sensor without temperature compensation structure are calculated. It is found by simulation that a ring-shaped structure on the diaphragm of the pressure sensor can mechanically suppress the thermal expansion effect of the sealed gas in the cavity. Pressure sensors without/with temperature compensation structures are fabricated and measured. Through measured results, it is verified that the calculation model is accurate. Using the compensation structures with a 900 μm inner radius, the measured temperature coefficient is much reduced as compared to that of the pressure sensor without compensation. The sensitivities of the pressure sensor before and after compensation are almost the same in the pressure range from 80 kPa to 100 kPa. PMID:22969385
Continued Development of Compact Multi-Gas Monitor for Life Support Systems Control in Space
NASA Technical Reports Server (NTRS)
Delgado, Jesus; Phillips, Straun; Chullen, Cinda
2015-01-01
Miniature optic gas sensors (MOGS) based on luminescent materials have shown great potential as alternatives to NIR-based gas sensor systems for the Portable Life Support System (PLSS). The unique capability of MOGS for carbon dioxide and oxygen monitoring under wet conditions has been reported, as has the fast recovery of MOGS humidity sensors after long periods of being wet. Lower volume and power requirements are also potential advantages of MOGS over both traditional and advanced Non-Dispersive Infrared (NDIR) gas sensors, which have shown so far longer life than luminescent sensors. In this paper we present the most recent results in the development and analytical validation of a compact multi-gas sensor unit based on luminescent sensors for the PLSS. Results of extensive testing are presented, including studies conducted at Intelligent Optical Systems laboratories, a United Technology Corporation Aerospace Systems (UTAS) laboratory, and a Johnson Space Center laboratory. The potential of this sensor technology for gas monitoring in PLSSs and other life support systems and the advantages and limitations found through detailed sensor validation are discussed.
NASA Technical Reports Server (NTRS)
Powell, Bradley W.; Burroughs, Ivan A.
1994-01-01
Through the two phases of this contract, sensors for welding applications and parameter extraction algorithms have been developed. These sensors form the foundation of a weld control system which can provide action weld control through the monitoring of the weld pool and keyhole in a VPPA welding process. Systems of this type offer the potential of quality enhancement and cost reduction (minimization of rework on faulty welds) for high-integrity welding applications. Sensors for preweld and postweld inspection, weld pool monitoring, keyhole/weld wire entry monitoring, and seam tracking were developed. Algorithms for signal extraction were also developed and analyzed to determine their application to an adaptive weld control system. The following sections discuss findings for each of the three sensors developed under this contract: (1) weld profiling sensor; (2) weld pool sensor; and (3) stereo seam tracker/keyhole imaging sensor. Hardened versions of these sensors were designed and built under this contract. A control system, described later, was developed on a multiprocessing/multitasking operating system for maximum power and flexibility. Documentation for sensor mechanical and electrical design is also included as appendices in this report.
Development of a portable petroleum by-products chemical sensor, phase 1 and 2 report.
DOT National Transportation Integrated Search
2006-07-31
We have proposed to tailor design nanoparticle based chemical sensors for the sensitive, selective and field portable analyses of soil samples for petroleum spill indicating hydrocarbons (such as benzene, toluene, ethyl-benzenes, xylenes, PCBs, trich...
Weigh-in-Motion Sensor and Controller Operation and Performance Comparison
DOT National Transportation Integrated Search
2018-01-01
This research project utilized statistical inference and comparison techniques to compare the performance of different Weigh-in-Motion (WIM) sensors. First, we analyzed test-vehicle data to perform an accuracy check of the results reported by the sen...
Magnetic sensor for nondestructive evaluation of deteriorated prestressing strand.
DOT National Transportation Integrated Search
2011-08-01
This is a report describing the activities and accomplishments in this project, completed through November 30, 2009. The overall goal of this project is to investigate the feasibility of a magnetic sensor to detect in-situ corrosion of prestressing s...
Heterogeneous regional signal control : final report.
DOT National Transportation Integrated Search
2017-03-12
The goal of this project is to develop a comprehensive framework with a set of models to improve multi-modal traffic signal control, by incorporating advanced floating sensor data (e.g. GPS data, etc.) and traditional fixed sensor data (e.g. loop det...
FogEye UV Sensor System Evaluation : Phase I Report.
DOT National Transportation Integrated Search
2002-09-01
FogEye technology uses the solar-blind reigion of the ultraviolet spectrum to develop sensors or systems that are unaffected by sunlight. The U.S. Congress asked the Federal Aviation Administration to investigate the feasibility of applying FogEye te...
Improved Sensitivity Spontaneous Raman Scattering Multi-Gas Sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buric, Michael P.; Chen, Kevin P.; Falk, Joel
2009-01-01
We report a backward-wave spontaneous-Raman multi-gas sensor employing a hollow-core photonic-bandgap-fiber to contain gasses and increase interaction length. Silica Raman noise and detection speed are reduced using a digital spatial filter and a cladding seal.
Aligner/Bonder for Fabrication of Nanoscale Spectral and Polarimetric Sensors
2008-11-26
SPECTRAL AND POLARIMETRIC SENSORS 5. FUNDING NUMBERS FA9550-07-1-0478 6. AUTHOR( S ) Prof. Sanjay Krishna (PI) 7. PERFORMING ORGANIZATION NAME( S ) AND...NUMBER Number 1 1 9. SPONSORING / MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSORING /MONITORING AGENCY REPORT NUMBER Dr. Donald Silversmith...AFOSR Program Manager 703 588 1780 II. SUPPLEMENTARY NOTES The views, opinions and/or findings contained in this report are those of the author( s
2017-09-01
and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188) Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT...KEY MANAGEMENT FOR SECURE NEIGHBOR DISCOVERY IN A DECENTRALIZED WIRELESS SENSOR NETWORK by Kelvin T. Chew September 2017 Thesis Advisor...DATE September 2017 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE SYMMETRIC LINK KEY MANAGEMENT FOR SECURE NEIGHBOR
Investigation of Antennas for a High-Sensitivity Polarization Measurement Sensor
2010-09-01
Burkholder and Chi-Chih Chen The Ohio State University ElectroScience Laboratory Department of Electrical Engineering Columbus, Ohio 43212 Final Report...Antennas for a High-Sensitivity Polarization Measurement Sensor 5. Report Date September 2010 6. 7. Author(s) Robert J. Burkholder and Chi-Chih Chen...POLARIZATION Mustafa Kuloglu, Robert J. Burkholder , and Chi-Chih Chen kuloglu.l@osu.edu, rjb@electroscience.osu.edu, chen.l 18@osu.edu ElectroScience
Deep Water Munitions Detection System
2010-03-01
information if it does not display a currently valid OMB control number. 1. REPORT DATE MAR 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00...water systems to deeper water depths would result in even greater costs. While some of the cost escalation may be unavoidable, it is desirable to...magnetometers, spaced 61 cm apart, on a towed sensor platform. The sensor platform has active control elements that allow its depth to be changed
Calibration of Smartphone-Based Weather Measurements Using Pairwise Gossip.
Zamora, Jane Louie Fresco; Kashihara, Shigeru; Yamaguchi, Suguru
2015-01-01
Accurate and reliable daily global weather reports are necessary for weather forecasting and climate analysis. However, the availability of these reports continues to decline due to the lack of economic support and policies in maintaining ground weather measurement systems from where these reports are obtained. Thus, to mitigate data scarcity, it is required to utilize weather information from existing sensors and built-in smartphone sensors. However, as smartphone usage often varies according to human activity, it is difficult to obtain accurate measurement data. In this paper, we present a heuristic-based pairwise gossip algorithm that will calibrate smartphone-based pressure sensors with respect to fixed weather stations as our referential ground truth. Based on actual measurements, we have verified that smartphone-based readings are unstable when observed during movement. Using our calibration algorithm on actual smartphone-based pressure readings, the updated values were significantly closer to the ground truth values.
Calibration of Smartphone-Based Weather Measurements Using Pairwise Gossip
Yamaguchi, Suguru
2015-01-01
Accurate and reliable daily global weather reports are necessary for weather forecasting and climate analysis. However, the availability of these reports continues to decline due to the lack of economic support and policies in maintaining ground weather measurement systems from where these reports are obtained. Thus, to mitigate data scarcity, it is required to utilize weather information from existing sensors and built-in smartphone sensors. However, as smartphone usage often varies according to human activity, it is difficult to obtain accurate measurement data. In this paper, we present a heuristic-based pairwise gossip algorithm that will calibrate smartphone-based pressure sensors with respect to fixed weather stations as our referential ground truth. Based on actual measurements, we have verified that smartphone-based readings are unstable when observed during movement. Using our calibration algorithm on actual smartphone-based pressure readings, the updated values were significantly closer to the ground truth values. PMID:26421312
Gould, Oliver; Wieczorek, Tomas; de Lacy Costello, Ben P J; Persad, Raj; Ratcliffe, Norman
2017-09-26
There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/ SnO2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These 2 different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. 29 chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but 2 instances the sensor exhibited the same or superior limit of detection compared to the MS. 12 stool samples from healthy participants were analysed, the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications. © 2017 IOP Publishing Ltd.
Gould, Oliver; Wieczorek, Tom; de Lacy Costello, Ben; Persad, Raj; Ratcliffe, Norman
2017-12-06
There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/SnO 2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These two different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. Twenty-nine chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but two instances the sensor exhibited the same or superior limit of detection compared to the MS. Twelve stool samples from healthy participants were analysed; the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly, analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications.
NASA Astrophysics Data System (ADS)
Francioso, L.; De Pascali, C.; Pescini, E.; De Giorgi, M. G.; Siciliano, P.
2016-06-01
Preventing the flow separation could enhance the performance of propulsion systems and future civil aircraft. To this end, a fast detection of boundary layer separation is mandatory for a sustainable and successful application of active flow control devices, such as plasma actuators. The present work reports on the design, fabrication and functional tests of low-cost capacitive pressure sensors coupled with dielectric barrier discharge (DBD) plasma actuators to detect and then control flow separation. Finite element method (FEM) simulations were used to obtain information on the deflection and the stress distribution in different-shaped floating membranes. The sensor sensitivity as a function of the pressure load was also calculated by experimental tests. The results of the calibration of different capacitive pressure sensors are reported in this work, together with functional tests in a wind tunnel equipped with a curved wall plate on which a DBD plasma actuator was mounted to control the flow separation. The flow behavior was experimentally investigated by particle image velocimetry (PIV) measurements. Statistical and spectral analysis, applied to the output signals of the pressure sensor placed downstream of the profile leading edge, demonstrated that the sensor is able to discriminate different ionic wind velocity and turbulence conditions. The sensor sensitivity in the 0-100 Pa range was experimentally measured and it ranged between 0.0030 and 0.0046 pF Pa-1 for the best devices.
Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.
Sameenoi, Yupaporn; Koehler, Kirsten; Shapiro, Jeff; Boonsong, Kanokporn; Sun, Yele; Collett, Jeffrey; Volckens, John; Henry, Charles S
2012-06-27
Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.
All-fiber intensity bend sensor based on photonic crystal fiber with asymmetric air-hole structure
NASA Astrophysics Data System (ADS)
Budnicki, Dawid; Szostkiewicz, Lukasz; Szymanski, Michal O.; Ostrowski, Lukasz; Holdynski, Zbigniew; Lipinski, Stanislaw; Murawski, Michal; Wojcik, Grzegorz; Makara, Mariusz; Poturaj, Krzysztof; Mergo, Pawel; Napierala, Marek; Nasilowski, Tomasz
2017-10-01
Monitoring the geometry of an moving element is a crucial task for example in robotics. The robots equipped with fiber bend sensor integrated in their arms can be a promising solution for medicine, physiotherapy and also for application in computer games. We report an all-fiber intensity bend sensor, which is based on microstructured multicore optical fiber. It allows to perform a measurement of the bending radius as well as the bending orientation. The reported solution has a special airhole structure which makes the sensor only bend-sensitive. Our solution is an intensity based sensor, which measures power transmitted along the fiber, influenced by bend. The sensor is based on a multicore fiber with the special air-hole structure that allows detection of bending orientation in range of 360°. Each core in the multicore fiber is sensitive to bend in specified direction. The principle behind sensor operation is to differentiate the confinement loss of fundamental mode propagating in each core. Thanks to received power differences one can distinguish not only bend direction but also its amplitude. Multicore fiber is designed to utilize most common light sources that operate at 1.55 μm thus ensuring high stability of operation. The sensitivity of the proposed solution is equal 29,4 dB/cm and the accuracy of bend direction for the fiber end point is up to 5 degrees for 15 cm fiber length. Such sensitivity allows to perform end point detection with millimeter precision.
Bismuth-Based, Disposable Sensor for the Detection of Hydrogen Sulfide Gas.
Rosolina, Samuel M; Carpenter, Thomas S; Xue, Zi-Ling
2016-02-02
A new sensor for the detection of hydrogen sulfide (H2S) gas has been developed to replace commercial lead(II) acetate-based test papers. The new sensor is a wet, porous, paper-like substrate coated with Bi(OH)3 or its alkaline derivatives at pH 11. In contrast to the neurotoxic lead(II) acetate, bismuth is used due to its nontoxic properties, as Bi(III) has been a reagent in medications such as Pepto-Bismol. The reaction between H2S gas and the current sensor produces a visible color change from white to yellow/brown, and the sensor responds to ≥ 30 ppb H2S in a total volume of 1.35 L of gas, a typical volume of human breath. The alkaline, wet coating helps the trapping of acidic H2S gas and its reaction with Bi(III) species, forming colored Bi2S3. The sensor is suitable for testing human bad breath and is at least 2 orders of magnitude more sensitive than a commercial H2S test paper based on Pb(II)(acetate)2. The small volume of 1.35-L H2S is important, as the commercial Pb(II)(acetate)2-based paper requires large volumes of 5 ppm H2S gas. The new sensor reported here is inexpensive, disposable, safe, and user-friendly. A simple, laboratory setup for generating small volumes of ppb-ppm of H2S gas is also reported.
Distributed multimodal data fusion for large scale wireless sensor networks
NASA Astrophysics Data System (ADS)
Ertin, Emre
2006-05-01
Sensor network technology has enabled new surveillance systems where sensor nodes equipped with processing and communication capabilities can collaboratively detect, classify and track targets of interest over a large surveillance area. In this paper we study distributed fusion of multimodal sensor data for extracting target information from a large scale sensor network. Optimal tracking, classification, and reporting of threat events require joint consideration of multiple sensor modalities. Multiple sensor modalities improve tracking by reducing the uncertainty in the track estimates as well as resolving track-sensor data association problems. Our approach to solving the fusion problem with large number of multimodal sensors is construction of likelihood maps. The likelihood maps provide a summary data for the solution of the detection, tracking and classification problem. The likelihood map presents the sensory information in an easy format for the decision makers to interpret and is suitable with fusion of spatial prior information such as maps, imaging data from stand-off imaging sensors. We follow a statistical approach to combine sensor data at different levels of uncertainty and resolution. The likelihood map transforms each sensor data stream to a spatio-temporal likelihood map ideally suitable for fusion with imaging sensor outputs and prior geographic information about the scene. We also discuss distributed computation of the likelihood map using a gossip based algorithm and present simulation results.
Design Methodology for Magnetic Field-Based Soft Tri-Axis Tactile Sensors.
Wang, Hongbo; de Boer, Greg; Kow, Junwai; Alazmani, Ali; Ghajari, Mazdak; Hewson, Robert; Culmer, Peter
2016-08-24
Tactile sensors are essential if robots are to safely interact with the external world and to dexterously manipulate objects. Current tactile sensors have limitations restricting their use, notably being too fragile or having limited performance. Magnetic field-based soft tactile sensors offer a potential improvement, being durable, low cost, accurate and high bandwidth, but they are relatively undeveloped because of the complexities involved in design and calibration. This paper presents a general design methodology for magnetic field-based three-axis soft tactile sensors, enabling researchers to easily develop specific tactile sensors for a variety of applications. All aspects (design, fabrication, calibration and evaluation) of the development of tri-axis soft tactile sensors are presented and discussed. A moving least square approach is used to decouple and convert the magnetic field signal to force output to eliminate non-linearity and cross-talk effects. A case study of a tactile sensor prototype, MagOne, was developed. This achieved a resolution of 1.42 mN in normal force measurement (0.71 mN in shear force), good output repeatability and has a maximum hysteresis error of 3.4%. These results outperform comparable sensors reported previously, highlighting the efficacy of our methodology for sensor design.
Design Methodology for Magnetic Field-Based Soft Tri-Axis Tactile Sensors
Wang, Hongbo; de Boer, Greg; Kow, Junwai; Alazmani, Ali; Ghajari, Mazdak; Hewson, Robert; Culmer, Peter
2016-01-01
Tactile sensors are essential if robots are to safely interact with the external world and to dexterously manipulate objects. Current tactile sensors have limitations restricting their use, notably being too fragile or having limited performance. Magnetic field-based soft tactile sensors offer a potential improvement, being durable, low cost, accurate and high bandwidth, but they are relatively undeveloped because of the complexities involved in design and calibration. This paper presents a general design methodology for magnetic field-based three-axis soft tactile sensors, enabling researchers to easily develop specific tactile sensors for a variety of applications. All aspects (design, fabrication, calibration and evaluation) of the development of tri-axis soft tactile sensors are presented and discussed. A moving least square approach is used to decouple and convert the magnetic field signal to force output to eliminate non-linearity and cross-talk effects. A case study of a tactile sensor prototype, MagOne, was developed. This achieved a resolution of 1.42 mN in normal force measurement (0.71 mN in shear force), good output repeatability and has a maximum hysteresis error of 3.4%. These results outperform comparable sensors reported previously, highlighting the efficacy of our methodology for sensor design. PMID:27563908
Reagentless, Structure-Switching, Electrochemical Aptamer-Based Sensors
NASA Astrophysics Data System (ADS)
Schoukroun-Barnes, Lauren R.; Macazo, Florika C.; Gutierrez, Brenda; Lottermoser, Justine; Liu, Juan; White, Ryan J.
2016-06-01
The development of structure-switching, electrochemical, aptamer-based sensors over the past ˜10 years has led to a variety of reagentless sensors capable of analytical detection in a range of sample matrices. The crux of this methodology is the coupling of target-induced conformation changes of a redox-labeled aptamer with electrochemical detection of the resulting altered charge transfer rate between the redox molecule and electrode surface. Using aptamer recognition expands the highly sensitive detection ability of electrochemistry to a range of previously inaccessible analytes. In this review, we focus on the methods of sensor fabrication and how sensor signaling is affected by fabrication parameters. We then discuss recent studies addressing the fundamentals of sensor signaling as well as quantitative characterization of the analytical performance of electrochemical aptamer-based sensors. Although the limits of detection of reported electrochemical aptamer-based sensors do not often reach that of gold-standard methods such as enzyme-linked immunosorbent assays, the operational convenience of the sensor platform enables exciting analytical applications that we address. Using illustrative examples, we highlight recent advances in the field that impact important areas of analytical chemistry. Finally, we discuss the challenges and prospects for this class of sensors.
Design of fiber optic based respiratory sensor for newborn incubator application
NASA Astrophysics Data System (ADS)
Dhia, Arika; Devara, Kresna; Abuzairi, Tomy; Poespawati, N. R.; Purnamaningsih, Retno W.
2018-02-01
This paper reports the design of respiratory sensor using fiber optic for newborn incubator application. The sensor works based on light intensity losses difference obtained due to thorax movement during respiration. The output of the sensor launched to support electronic circuits to be processed in Arduino Uno microcontroler such that the real-time respiratory rate (breath per minute) can be presented on LCD. Experiment results using thorax expansion of newborn simulator show that the system is able to measure respiratory rate from 10 up to 130 breaths per minute with 0.595% error and 0.2% hysteresis error.
Micro- and Nanostructured Metal Oxide Chemical Sensors for Volatile Organic Compounds
NASA Technical Reports Server (NTRS)
Alim, M. A.; Penn, B. G.; Currie, J. R., Jr.; Batra, A. K.; Aggarwal, M. D.
2008-01-01
Aeronautic and space applications warrant the development of chemical sensors which operate in a variety of environments. This technical memorandum incorporates various kinds of chemical sensors and ways to improve their performance. The results of exploratory investigation of the binary composite polycrystalline thick-films such as SnO2-WO3, SnO2-In2O3, SnO2-ZnO for the detection of volatile organic compound (isopropanol) are reported. A short review of the present status of the new types of nanostructured sensors such as nanobelts, nanorods, nanotube, etc. based on metal oxides is presented.
Magneto-photonic crystal optical sensors with sensitive covers
NASA Astrophysics Data System (ADS)
Dissanayake, Neluka; Levy, Miguel; Chakravarty, A.; Heiden, P. A.; Chen, N.; Fratello, V. J.
2011-08-01
We report on a magneto-photonic crystal on-chip optical sensor for specific analyte detection with polypyrrole and gold nano particles as modified photonic crystal waveguide cover layers. The reaction of the active sensor material with various analytes modifies the electronic structure of the sensor layer causing changes in its refractive index and a strong transduction signal. Magneto-photonic crystal enhanced polarization rotation sensitive to the nature of the cover layer detects the index modification upon analyte adsorption. A high degree of selectivity and sensitivity are observed for aqueous ammonia and methanol with polypyrrole and for thiolated-gold- with gold-nanoparticles covers.
NASA Astrophysics Data System (ADS)
Li, Chunyan; Wu, Pei-Ming; Shutter, Lori A.; Narayan, Raj K.
2010-02-01
The dual-mode operation of a polyvinylidene fluoride trifluoroethylene (PVDF-TrFE) piezoelectric polymer diaphragm, in a capacitive or resonant mode, is reported as a flexible intracranial pressure (ICP) sensor. The pressure sensor using a capacitive mode exhibits a higher linearity and less power consumption than resonant mode operated pressure sensor. In contrast, the latter provides better sensitivity and easier adaption for wireless application. The metrological properties of the dual-mode ICP sensor being described are satisfactory in vitro. We propose that the piezoelectric polymer diaphragm has a promising future in intracranial pressure monitoring.
Considerations for multiple hypothesis correlation on tactical platforms
NASA Astrophysics Data System (ADS)
Thomas, Alan M.; Turpen, James E.
2013-05-01
Tactical platforms benefit greatly from the fusion of tracks from multiple sources in terms of increased situation awareness. As a necessary precursor to this track fusion, track-to-track association, or correlation, must first be performed. The related measurement-to-track fusion problem has been well studied with multiple hypothesis tracking and multiple frame assignment methods showing the most success. The track-to-track problem differs from this one in that measurements themselves are not available but rather track state update reports from the measuring sensors. Multiple hypothesis, multiple frame correlation systems have previously been considered; however, their practical implementation under the constraints imposed by tactical platforms is daunting. The situation is further exacerbated by the inconvenient nature of reports from legacy sensor systems on bandwidth- limited communications networks. In this paper, consideration is given to the special difficulties encountered when attempting the correlation of tracks from legacy sensors on tactical aircraft. Those difficulties include the following: covariance information from reporting sensors is frequently absent or incomplete; system latencies can create temporal uncertainty in data; and computational processing is severely limited by hardware and architecture. Moreover, consideration is given to practical solutions for dealing with these problems in a multiple hypothesis correlator.
Microtubular conductometric biosensor for ethanol detection.
Ajay, A K; Srivastava, Divesh N
2007-09-30
A conductometric sensor using microtubules of polyaniline as transducer cum immobilization matrix is reported, capable of detecting ethanol in liquid phase. Enzyme ADH (alcohol dehydrogenase) and its coenzyme NAD+ have been used to improve the selectivity of the sensor. The sensor concept is based on the protonation of the polyaniline by the hydrogen ion produced in the enzyme-catalyzed reaction, leading to changes in the electrical conductance of the polyaniline. The sensor works well on the physiological pH, can detect ethanol as low as 0.02% (v/v) (0.092 M) and has a linear trend at par healthcare guidelines. The sensor responses were measured in various permutation and combination of enzyme and coenzyme concentrations and site of immobilization. The sensor shows minor interference with other functional groups and alcohols. The possible causes for such interference have been discussed.
Fully wireless pressure sensor based on endoscopy images
NASA Astrophysics Data System (ADS)
Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni
2018-04-01
In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.
Performance improvement of IPMC flow sensors with a biologically-inspired cupula structure
NASA Astrophysics Data System (ADS)
Lei, Hong; Sharif, Montassar Aidi; Paley, Derek A.; McHenry, Matthew J.; Tan, Xiaobo
2016-04-01
Ionic polymer-metal composites (IPMCs) have inherent underwater sensing and actuation properties. They can be used as sensors to collect flow information. Inspired by the hair-cell mediated receptor in the lateral line system of fish, the impact of a flexible, cupula-like structure on the performance of IPMC flow sensors is experimentally explored. The fabrication method to create a silicone-capped IPMC sensor is reported. Experiments are conducted to compare the sensing performance of the IPMC flow sensor before and after the PDMS coating under the periodic flow stimulus generated by a dipole source in still water and the laminar flow stimulus generated in a flow tank. Experimental results show that the performance of IPMC flow sensors is significantly improved under the stimulus of both periodic flow and laminar flow by the proposed silicone-capping.
Murayama, Takashi; Maruyama, Ichiro N
2015-11-01
Animals can survive only within a narrow pH range. This requires continual monitoring of environmental and body-fluid pH. Although a variety of acidic pH sensor molecules have been reported, alkaline pH sensor function is not well understood. This Review describes neuronal alkaline pH sensors, grouped according to whether they monitor extracellular or intracellular alkaline pH. Extracellular sensors include the receptor-type guanylyl cyclase, the insulin receptor-related receptor, ligand-gated Cl- channels, connexin hemichannels, two-pore-domain K+ channels, and transient receptor potential (TRP) channels. Intracellular sensors include TRP channels and gap junction channels. Identification of molecular mechanisms underlying alkaline pH sensing is crucial for understanding how animals respond to environmental alkaline pH and how body-fluid pH is maintained within a narrow range. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Grimes, C. A.; Kouzoudis, D.
2000-01-01
Free-standing magnetoelastic thick-film sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted from the sensor in response to a time varying magnetic field. This property allows the sensors to be monitored remotely without the use of direct physical connections, such as wires, enabling measurement of environmental parameters from within sealed, opaque containers. In this work, we report on application of magnetoelastic sensors to measurement of atmospheric pressure, fluid-flow velocity, temperature, and mass load. Mass loading effects are demonstrated by fabrication of a remote query humidity sensor, made by coating the magnetoelastic thick film with a thin layer of solgel deposited Al2O3 that reversibly changes mass in response to humidity. c2000 Elsevier Science S.A. All rights reserved.
NASA Astrophysics Data System (ADS)
Su, Jun; Yang, Ning; Fan, Zhiqiang; Qiu, Qi
2017-10-01
We report on a fiber-optic delay-based quasidistributed temperature sensor with high precision. The device works by detecting the delay induced by the temperature instead of the spectrum. To analyze the working principle of this sensor, the thermal dependence of the fiber-optic delay was theoretically investigated and the delay-temperature coefficient was measured to be 42.2 ps/km°C. In this sensor, quasidistributed measurement of temperature could be easily realized by dense wavelength-division multiplexing and wavelength addressing. We built and tested a prototype quasidistributed temperature sensor with eight testing points equally distributed along a 32.61-km-long fiber. The experimental results demonstrate an average error of <0.1°C. These results prove that this quasidistributed temperature sensor is feasible and that it is a viable option for simple and economic temperature measurements.
Sum, K W; Zheng, Y P; Mak, A F T
2005-01-01
This paper describes the development of a miniaturized wearable vital sign monitor which is aimed for use by elderly at home. The development of a compound sensor for pulse rate, motion, and skin temperature is reported. A pair of infrared sensor working in reflection mode was used to detect the pulse rate from various sites over the body including the wrist and finger. Meanwhile, a motion sensor was used to detect the motion of the body. In addition, the temperature on the skin surface was sensed by a semiconductor temperature sensor. A prototype has been built into a box with a dimension of 2 x 2.5 x 4 cm3. The device includes the sensors, microprocessor, circuits, battery, and a wireless transceiver for communicating data with a data terminal.
NASA Astrophysics Data System (ADS)
Kohyama, Sumihiro; Takahashi, Hidetoshi; Yoshida, Satoru; Onoe, Hiroaki; Hirayama-Shoji, Kayoko; Tsukagoshi, Takuya; Takahata, Tomoyuki; Shimoyama, Isao
2018-04-01
This paper reports on a method to measure a spring constant on site using a micro electro mechanical systems (MEMS) force and displacement sensor. The proposed sensor consists of a force-sensing cantilever and a displacement-sensing cantilever. Each cantilever is composed of two beams with a piezoresistor on the sidewall for measuring the in-plane lateral directional force and displacement. The force resolution and displacement resolution of the fabricated sensor were less than 0.8 µN and 0.1 µm, respectively. We measured the spring constants of two types of hydrogel microparticles to demonstrate the effectiveness of the proposed sensor, with values of approximately 4.3 N m-1 and 15.1 N m-1 obtained. The results indicated that the proposed sensor is effective for on-site spring constant measurement.
Satellite passive remote sensing of off-shore pollutants, volume 2
NASA Technical Reports Server (NTRS)
1979-01-01
Satellite detection and monitoring of off-shore dumped pollutants, other than oil, are discussed. Summaries of satellite sensor performance in three spectral bands (visible, infrared, and microwave) are presented. The bulk of the report gives all the calculations, trade-offs and limitations of the three sensor systems. It is asserted that the problem of pollution monitoring is not a sensor problem but a problem of mathematical modeling and data processing.
2000-08-01
forefoot with the foot in the neutral position, and (b) similar to (a) but with heel landing. Although the authors reported no absolute strain values...diameter of sensors (or, in the case of a rectangular sensor, width as measured along pin axis). Worst case : Strike line from inside edges of sensors...potoroo it is just prior to "toe strike ". The locomotion of the potoroo is described as digitigrade, unlike humans, who walk in a plantigrade manner
2015 USAFA Research Report: Discover Falcon Innovation
2015-01-01
delivery system deployed from a canister. Their solution allows the canister to release hundreds of the sensors at the right angle and in waves so that...Computer Science at the Air Force Academy. The center develops sensors for the aircraft – it uses commercially available UAVs known as Haulers – to allow... sensors and software development, said Tim McCarthy, one of the co-founders of Aspect Robotics. During the last semester, Academy cadets in the
Active Control of Surge in Compressors Which Exhibit Abrupt Stall
2001-06-01
sensor (of pressure, flow rate, etc.) is fed to a controller which applies a proper control law to drive the actuator (valve, The present paper reports...1993), who analyzed the influence of sensor and numerical simulation shows that: t) the predictions of control acutrsltin o th mxmm sabizd opesr...a sensor of compressor face total pressure), a The present paper considers the active suppression of surge in a butterfly throttle/actuation valve
Earth Sensor Assembly for the Tropical Rainfall Measuring Mission Observatory
NASA Technical Reports Server (NTRS)
Prince, Steven S.; Hoover, James M.
1995-01-01
EDO Corporation/Barnes Engineering Division (BED) has provided the Tropical Rainfall Measurement Mission (TRMM) Earth Sensor Assembly (ESA), a key element in the TRMM spacecraft's attitude control system. This report documents the history, design, fabrication, assembly, and test of the ESA.
Resilient Localization for Sensor Networks in Outdoor Environments
2004-06-01
Sensor Networks in Outdoor Environments by YoungMin Kwon, Kirill Mechitov, Sameer Sundresh, Wooyoung Kim and Gul Agha June 2004 Report...Environments YoungMin Kwon, Kirill Mechitov, Sameer Sundresh, Wooyoung Kim and Gul Agha Department of Computer Science University of Illinois at Urbana
A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements
NASA Astrophysics Data System (ADS)
Dennison, Christopher R.; Wild, Peter M.; Wilson, David R.; Cripton, Peter A.
2008-08-01
We present an in-fiber Bragg grating (FBG) based intervertebral disc (IVD) pressure sensor that has pressure sensitivity seven times greater than that of a bare fiber, and a major diameter and sensing area of only 400 µm and 0.03 mm2, respectively. This is the only optical, the smallest and the most mechanically compliant disc pressure sensor reported in the literature. This is also an improvement over other FBG pressure sensors that achieve increased sensitivity through mechanical amplification schemes, usually resulting in major diameters and sensing lengths of many millimeters. Sensor sensitivity is predicted using numerical models, and the predicted sensitivity is verified through experimental calibrations. The sensor is validated by conducting IVD pressure measurements in porcine discs and comparing the FBG measurements to those obtained using the current standard sensor for IVD pressure. The predicted sensitivity of the FBG sensor matched with that measured experimentally. IVD pressure measurements showed excellent repeatability and agreement with those obtained from the standard sensor. Unlike the current larger sensors, the FBG sensor could be used in discs with small disc height (i.e. cervical or degenerated discs). Therefore, there is potential to conduct new measurements that could lead to new understanding of the biomechanics.
Development and evaluation of optical fiber NH3 sensors for application in air quality monitoring
NASA Astrophysics Data System (ADS)
Huang, Yu; Wieck, Lucas; Tao, Shiquan
2013-02-01
Ammonia is a major air pollutant emitted from agricultural practices. Sources of ammonia include manure from animal feeding operations and fertilizer from cropping systems. Sensor technologies with capability of continuous real time monitoring of ammonia concentration in air are needed to qualify ammonia emissions from agricultural activities and further evaluate human and animal health effects, study ammonia environmental chemistry, and provide baseline data for air quality standard. We have developed fiber optic ammonia sensors using different sensing reagents and different polymers for immobilizing sensing reagents. The reversible fiber optic sensors have detection limits down to low ppbv levels. The response time of these sensors ranges from seconds to tens minutes depending on transducer design. In this paper, we report our results in the development and evaluation of fiber optic sensor technologies for air quality monitoring. The effect of change of temperature, humidity and carbon dioxide concentration on fiber optic ammonia sensors has been investigated. Carbon dioxide in air was found not interfere the fiber optic sensors for monitoring NH3. However, the change of humidity can cause interferences to some fiber optic NH3 sensors depending on the sensor's transducer design. The sensitivity of fiber optic NH3 sensors was found depends on temperature. Methods and techniques for eliminating these interferences have been proposed.
International Space Station Increment-4/5 Microgravity Environment Summary Report
NASA Technical Reports Server (NTRS)
Jules, Kenol; Hrovat, Kenneth; Kelly, Eric; McPherson, Kevin; Reckart, Timothy
2003-01-01
This summary report presents the results of some of the processed acceleration data measured aboard the International Space Station during the period of December 2001 to December 2002. Unlike the past two ISS Increment reports, which were increment specific, this summary report covers two increments: Increments 4 and 5, hereafter referred to as Increment-4/5. Two accelerometer systems were used to measure the acceleration levels for the activities that took place during Increment-4/5. Due to time constraint and lack of precise timeline information regarding some payload operations and station activities, not a11 of the activities were analyzed for this report. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Microgravity System to support microgravity science experiments which require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System supports science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit supports experiments requiring vibratory acceleration measurement. The International Space Station Increment-4/5 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: The Microgravity Acceleration Measurement System, which consists of two sensors: the low-frequency Orbital Acceleration Research Experiment Sensor Subsystem and the higher frequency High Resolution Accelerometer Package. The low frequency sensor measures up to 1 Hz, but is routinely trimmean filtered to yield much lower frequency acceleration data up to 0.01 Hz. This filtered data can be mapped to arbitrary locations for characterizing the quasi-steady environment for payloads and the vehicle. The high frequency sensor is used to characterize the vibratory environment up to 100 Hz at a single measurement location. The Space Acceleration Measurement System, which deploys high frequency sensors, measures vibratory acceleration data in the range of 0.01 to 400 Hz at multiple measurement locations. This summary report presents analysis of some selected quasi-steady and vibratory activities measured by these accelerometers during Increment- 4/5 from December 2001 to December 2002.
Experimental Verification of Buffet Calculation Procedure Using Unsteady PSP
NASA Technical Reports Server (NTRS)
Panda, Jayanta
2016-01-01
Typically a limited number of dynamic pressure sensors are employed to determine the unsteady aerodynamic forces on large, slender aerospace structures. The estimated forces are known to be very sensitive to the number of the dynamic pressure sensors and the details of the integration scheme. This report describes a robust calculation procedure, based on frequency-specific correlation lengths, that is found to produce good estimation of fluctuating forces from a few dynamic pressure sensors. The validation test was conducted on a flat panel, placed on the floor of a wind tunnel, and was subjected to vortex shedding from a rectangular bluff-body. The panel was coated with fast response Pressure Sensitive Paint (PSP), which allowed time-resolved measurements of unsteady pressure fluctuations on a dense grid of spatial points. The first part of the report describes the detail procedure used to analyze the high-speed, PSP camera images. The procedure includes steps to reduce contamination by electronic shot noise, correction for spatial non-uniformities, and lamp brightness variation, and finally conversion of fluctuating light intensity to fluctuating pressure. The latter involved applying calibration constants from a few dynamic pressure sensors placed at selective points on the plate. Excellent comparison in the spectra, coherence and phase, calculated via PSP and dynamic pressure sensors validated the PSP processing steps. The second part of the report describes the buffet validation process, for which the first step was to use pressure histories from all PSP points to determine the "true" force fluctuations. In the next step only a selected number of pixels were chosen as "virtual sensors" and a correlation-length based buffet calculation procedure was applied to determine "modeled" force fluctuations. By progressively decreasing the number of virtual sensors it was observed that the present calculation procedure was able to make a close estimate of the "true" unsteady forces only from four sensors. It is believed that the present work provides the first validation of the buffet calculation procedure which has been used for the development of many space vehicles.
NASA Astrophysics Data System (ADS)
Ouiganon, Sirirat; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya; Buranachai, Chittanon
2016-06-01
This work reports a novel enzyme-free sugar sensor development based on optical coherence tomography (OCT) and a 3-acrylamidophenylboronic acid-acrylamide copolymer gel that swells when it binds sugar molecules. Utilizing OCT to measure the gel swelling in the presence of glucose and fructose, selected as model targets, the sensor provided a linear range of 2.5-20.0 mM for glucose and 0.01-0.20 mM for fructose detections with a good sensitivity for both sugars under optimal conditions. With some further improvements, the sensor could be used in harsh conditions that are not suitable for enzyme-based sugar sensors and for highly visible light-absorbing solutions.
Umar, Ahmad; Lee, Jong-Heun; Kumar, Rajesh; Al-Dossary, O
2017-02-01
Herein, the fabrication and characterization of highly sensitive and selective ethanol gas sensor based on CuO nanodisks is reported. The CuO nanodisks were synthesized by facile hydrothermal process and detailed characterization revealed the well-crystallinity, high-purity and high density growth of the prepared material. To fabricate the ethanol gas sensor, the prepared nanodisks were coated on alumina substrate. The fabricated sensor exhibited high-sensitivity and the recorded gas response (resistance-ratio), response time (τ res) and recovery time (τ recov) were 6.2, 119 and 35 s, respectively for 100 ppm of C₂H₅OH at 300 °C. Further, the fabricated sensor shows high selectivity towards ethanol gas compared to H₂ and CO gases.
Irradiation tests of ITER candidate Hall sensors using two types of neutron spectra.
Ďuran, I; Bolshakova, I; Viererbl, L; Sentkerestiová, J; Holyaka, R; Lahodová, Z; Bém, P
2010-10-01
We report on irradiation tests of InSb based Hall sensors at two irradiation facilities with two distinct types of neutron spectra. One was a fission reactor neutron spectrum with a significant presence of thermal neutrons, while another one was purely fast neutron field. Total neutron fluence of the order of 10(16) cm(-2) was accumulated in both cases, leading to significant drop of Hall sensor sensitivity in case of fission reactor spectrum, while stable performance was observed at purely fast neutron spectrum. This finding suggests that performance of this particular type of Hall sensors is governed dominantly by transmutation. Additionally, it further stresses the need to test ITER candidate Hall sensors under neutron flux with ITER relevant spectrum.
A photonic crystal fiber glucose sensor filled with silver nanowires
NASA Astrophysics Data System (ADS)
Yang, X. C.; Lu, Y.; Wang, M. T.; Yao, J. Q.
2016-01-01
We report a photonic crystal fiber glucose sensor filled with silver nanowires in this paper. The proposed sensor is both analyzed by COMSOL multiphysics software and demonstrated by experiments. The extremely high average spectral sensitivity 19009.17 nm/RIU for experimental measurement is obtained, equivalent to 44.25 mg/dL of glucose in water, which is lower than 70 mg/dL for efficient detection of hypoglycemia episodes. The silver nanowires diameter which may affect the sensor's spectral sensitivity is also discussed and an optimal range of silver nanowires diameter 90-120 nm is obtained. We expect that the sensor can provide an effective platform for glucose sensing and potentially leading to a further development towards minimal-invasive glucose measurement.
Probabilistic objective functions for sensor management
NASA Astrophysics Data System (ADS)
Mahler, Ronald P. S.; Zajic, Tim R.
2004-08-01
This paper continues the investigation of a foundational and yet potentially practical basis for control-theoretic sensor management, using a comprehensive, intuitive, system-level Bayesian paradigm based on finite-set statistics (FISST). In this paper we report our most recent progress, focusing on multistep look-ahead -- i.e., allocation of sensor resources throughout an entire future time-window. We determine future sensor states in the time-window using a "probabilistically natural" sensor management objective function, the posterior expected number of targets (PENT). This objective function is constructed using a new "maxi-PIMS" optimization strategy that hedges against unknowable future observation-collections. PENT is used in conjuction with approximate multitarget filters: the probability hypothesis density (PHD) filter or the multi-hypothesis correlator (MHC) filter.
Failure monitoring of E-glass/vinylester composites using fiber grating acoustic sensor
NASA Astrophysics Data System (ADS)
Azmi, A. I.; Raju; Peng, G. D.
2013-06-01
This paper reports an application of an optical fiber sensor in a continuous and in situ failure testing of an E-glass/vinylester top hat stiffener (THS). The sensor head was constructed from a compact phase-shifted fiber Bragg grating (PS-FBG). The narrow transmission channel of the PS-FBG is highly sensitive to small perturbation, hence suitable to be used in acoustic emission (AE) assessment technique. The progressive failure of THS was tested under transverse loading to experimentally simulate the actual loading in practice. Our experimental tests have demonstrated, in good agreement with the commercial piezoelectric sensors, that the important failures information of the THS was successfully recorded by the simple intensity-type PS-FBG sensor.
A sensitive, handheld vapor sensor based on microcantilevers
NASA Astrophysics Data System (ADS)
Pinnaduwage, L. A.; Hedden, D. L.; Gehl, A.; Boiadjiev, V. I.; Hawk, J. E.; Farahi, R. H.; Thundat, T.; Houser, E. J.; Stepnowski, S.; McGill, R. A.; Deel, L.; Lareau, R. T.
2004-11-01
We report the development of a handheld sensor based on piezoresistive microcantilevers that does not depend on optical detection, yet has high detection sensitivity. The sensor is able to detect vapors from the plastic explosives pentaerythritol tetranitrate and hexahydro-1,3,5-triazine at levels below 10 parts per trillion within few seconds of exposure under ambient conditions. A differential measurement technique has yielded a rugged sensor that is unaffected by vibration and is able to function as a "sniffer." The microelectromechanical system sensor design allows for the incorporation of hundreds of microcantilevers with suitable coatings in order to achieve sufficient selectivity in the future, and thus could provide an inexpensive, unique platform for the detection of chemical, biological, and explosive materials.
Research on a haptic sensor made using MCF conductive rubber
NASA Astrophysics Data System (ADS)
Zheng, Yaoyang; Shimada, Kunio
2008-05-01
To provide a new composite material having a high electrical sensitivity in the fields of robotics and sensing, a magnetic rubber having network-like magnetic clusters was developed by utilizing a magnetic compound fluid (MCF). MCF rubber with small deformations can provide an effective sensor. In this paper, we report many experiments in which changes of the MCF rubber's resistance were observed when the rubber was compressed and a deformation was generated; we then made a trial haptic sensor using the MCF conductive rubber and performed many experiments to observe changes of the electrical resistance of the sensor. The results of experiments showed that the proposed sensor made with MCF conductive rubber is useful for sensing small amounts of pressure or small deformations.
Research on a haptic sensor made using MCF conductive rubber.
Zheng, Yaoyang; Shimada, Kunio
2008-05-21
To provide a new composite material having a high electrical sensitivity in the fields of robotics and sensing, a magnetic rubber having network-like magnetic clusters was developed by utilizing a magnetic compound fluid (MCF). MCF rubber with small deformations can provide an effective sensor. In this paper, we report many experiments in which changes of the MCF rubber's resistance were observed when the rubber was compressed and a deformation was generated; we then made a trial haptic sensor using the MCF conductive rubber and performed many experiments to observe changes of the electrical resistance of the sensor. The results of experiments showed that the proposed sensor made with MCF conductive rubber is useful for sensing small amounts of pressure or small deformations.
Energy scavenging sensors for ultra-low power sensor networks
NASA Astrophysics Data System (ADS)
O'Brien, Dominic C.; Liu, Jing Jing; Faulkner, Grahame E.; Vachiramon, Pithawat; Collins, Steve; Elston, Steven J.
2010-08-01
The 'internet of things' will require very low power wireless communications, preferably using sensors that scavenge power from their environment. Free space optics allows communications over long ranges, with simple transceivers at each end, offering the possibility of low energy consumption. In addition there can be sufficient energy in the communications beam to power simple terminals. In this paper we report experimental results from an architecture that achieves this. A base station that tracks sensors in its coverage area and communicates with them using low divergence optical beams is presented. Sensor nodes use modulated retro-reflectors to communicate with the base station, and the nodes are powered by the illuminating beam. The paper presents design and implementation details, as well as future directions for this work.
2014-04-24
other sensors … will deprive an opponent of initiative on the battlefield and [make it difficult] for them to bring their precision guided weapons...features include modern avionics and sensors that offer more timely situational awareness for operations in network-centric combat environments...JF12 hypersonic wind tunnel, reportedly the largest in the world, capable of replicating flying conditions at mach 5 to 9. This project was one of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ethelfeld, J.
The report is made to help the owners and the technical personnel of old wind mills: to make a new induction sensor which gives a quick activation of the original brake activation system; to build a new brake activation system, with its own new independent induction sensor system; and to change the (original) centrifugal switch for the brake so that a quicker activation is obtained.
Ultrasensitive FRET-based DNA sensor using PNA/DNA hybridization.
Yang, Lan-Hee; Ahn, Dong June; Koo, Eunhae
2016-12-01
In the diagnosis of genetic diseases, rapid and highly sensitive DNA detection is crucial. Therefore, many strategies for detecting target DNA have been developed, including electrical, optical, and mechanical methods. Herein, a highly sensitive FRET based sensor was developed by using PNA (Peptide Nucleic Acid) probe and QD, in which red color QDs are hybridized with capture probes, reporter probes and target DNAs by EDC-NHS coupling. The hybridized probe with target DNA gives off fluorescent signal due to the energy transfer from QD to Cy5 dye in the reporter probe. Compared to the conventional DNA sensor using DNA probes, the DNA sensor using PNA probes shows higher FRET factor and efficiency due to the higher reactivity between PNA and target DNA. In addition, to elicit the effect of the distance between the donor and the acceptor, we have investigated two types of the reporter probes having Cy5 dyes attached at the different positions of the reporter probes. Results show that the shorter the distance between QDs and Cy5s, the stronger the signal intensity. Furthermore, based on the fluorescence microscopy images using microcapillary chips, the FRET signal is enhanced to be up to 276% times stronger than the signal obtained using the cuvette by the fluorescence spectrometer. These results suggest that the PNA probe system conjugated with QDs can be used as ultrasensitive DNA nanosensors. Copyright © 2016. Published by Elsevier B.V.
Wearable technology for spine movement assessment: A systematic review.
Papi, Enrica; Koh, Woon Senn; McGregor, Alison H
2017-11-07
Continuous monitoring of spine movement function could enhance our understanding of low back pain development. Wearable technologies have gained popularity as promising alternative to laboratory systems in allowing ambulatory movement analysis. This paper aims to review the state of art of current use of wearable technology to assess spine kinematics and kinetics. Four electronic databases and reference lists of relevant articles were searched to find studies employing wearable technologies to assess the spine in adults performing dynamic movements. Two reviewers independently identified relevant papers. Customised data extraction and quality appraisal form were developed to extrapolate key details and identify risk of biases of each study. Twenty-two articles were retrieved that met the inclusion criteria: 12 were deemed of medium quality (score 33.4-66.7%), and 10 of high quality (score >66.8%). The majority of articles (19/22) reported validation type studies. Only 6 reported data collection in real-life environments. Multiple sensors type were used: electrogoniometers (3/22), strain gauges based sensors (3/22), textile piezoresistive sensor (1/22) and accelerometers often used with gyroscopes and magnetometers (15/22). Two sensors units were mainly used and placing was commonly reported on the spine lumbar and sacral regions. The sensors were often wired to data transmitter/logger resulting in cumbersome systems. Outcomes were mostly reported relative to the lumbar segment and in the sagittal plane, including angles, range of motion, angular velocity, joint moments and forces. This review demonstrates the applicability of wearable technology to assess the spine, although this technique is still at an early stage of development. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Unsteady Heat-Flux Measurements of Second-Mode Instability Waves in a Hypersonic Boundary Layer
NASA Technical Reports Server (NTRS)
Kergerise, Michael A.; Rufer, Shann J.
2016-01-01
In this paper we report on the application of the atomic layer thermopile (ALTP) heat- flux sensor to the measurement of laminar-to-turbulent transition in a hypersonic flat plate boundary layer. The centerline of the flat-plate model was instrumented with a streamwise array of ALTP sensors and the flat-plate model was exposed to a Mach 6 freestream over a range of unit Reynolds numbers. Here, we observed an unstable band of frequencies that are associated with second-mode instability waves in the laminar boundary layer that forms on the flat-plate surface. The measured frequencies, group velocities, phase speeds, and wavelengths of these instability waves are in agreement with data previously reported in the literature. Heat flux time series, and the Morlet-wavelet transforms of them, revealed the wave-packet nature of the second-mode instability waves. In addition, a laser-based radiative heating system was developed to measure the frequency response functions (FRF) of the ALTP sensors used in the wind tunnel test. These measurements were used to assess the stability of the sensor FRFs over time and to correct spectral estimates for any attenuation caused by the finite sensor bandwidth.
A nanocomposite-based electrochemical sensor for non-enzymatic detection of hydrogen peroxide
Du, Xin; Chen, Yuan; Dong, Wenhao; Han, Bingkai; Liu, Min; Chen, Qiang; Zhou, Jun
2017-01-01
Hydrogen peroxide (H2O2) plays important signaling roles in normal physiology and disease. However, analyzing the actions of H2O2 is often impeded by the difficulty in detecting this molecule. Herein, we report a novel nanocomposite-based electrochemical sensor for non-enzymatic detection of H2O2. Graphene oxide (GO) was selected as the dopant for the synthesis of polyaniline (PANI), leading to the successful fabrication of a water-soluble and stable GO-PANI composite. GO-PANI was subsequently subject to cyclic voltammetry to generate reduced GO-PANI (rGO-PANI), enhancing the conductivity of the material. Platinum nanoparticles (PtNPs) were then electrodeposited on the surface of the rGO-PANI-modified glassy carbon electrode (GCE) to form an electrochemical H2O2 sensor. Compared to previously reported sensors, the rGO-PANI-PtNP/GCE exhibited an expanded linear range, higher sensitivity, and lower detection limit in the quantification of H2O2. In addition, the sensor displayed outstanding reproducibility and selectivity in real-sample examination. Our study suggests that the rGO-PANI-PtNP/GCE may have broad utility in H2O2 detection under physiological and pathological conditions. PMID:28035076
Irawan, Rudi; Chuan, Tjin Swee; Meng, Tay Chia; Ming, Tan Khay
2008-06-27
Exposing an optical fiber core to the measurand surrounding the fiber is often used to enhance the sensitivity of an optical fiber sensor. This paper reports on the rapid fabrication of microstructures in an optical fiber using a CO₂ laser system which help exposing the optical fiber core to the measurand. The direct-write CO₂ laser system used is originally designed for engraving the polymeric material. Fabrications of microstructures such as in-fiber microhole, D-shaped fiber, in-fiber microchannel, side-sliced fiber and tapered fiber were attempted. The microstructures in the fibers were examined using a SEM and an optical microscope. Quality of microstructures shown by the SEM images and promising results from fluorescence sensor tests using in-fiber microchannels of 100μm width, 210μm depth and 10mm length show the prospect of this method for use in optical fiber sensor development. The direct-write CO₂ laser system is a flexible and fast machining tool for fabricating microstructures in an optical fiber, and can possibly be a replacement of the time consuming chemical etching and polishing methods used for microstructure fabrications of optical the fiber sensors reported in other literatures.
Rapid Constructions of Microstructures for Optical Fiber Sensors Using a Commercial CO2 Laser System
Irawan, Rudi; Chuan, Tjin Swee; Meng, Tay Chia; Ming, Tan Khay
2008-01-01
Exposing an optical fiber core to the measurand surrounding the fiber is often used to enhance the sensitivity of an optical fiber sensor. This paper reports on the rapid fabrication of microstructures in an optical fiber using a CO2 laser system which help exposing the optical fiber core to the measurand. The direct-write CO2 laser system used is originally designed for engraving the polymeric material. Fabrications of microstructures such as in-fiber microhole, D-shaped fiber, in-fiber microchannel, side-sliced fiber and tapered fiber were attempted. The microstructures in the fibers were examined using a SEM and an optical microscope. Quality of microstructures shown by the SEM images and promising results from fluorescence sensor tests using in-fiber microchannels of 100μm width, 210μm depth and 10mm length show the prospect of this method for use in optical fiber sensor development. The direct-write CO2 laser system is a flexible and fast machining tool for fabricating microstructures in an optical fiber, and can possibly be a replacement of the time consuming chemical etching and polishing methods used for microstructure fabrications of optical the fiber sensors reported in other literatures. PMID:19662114
Martinez, Jennifer S [Santa Fe, NM; Swanson, Basil I [Los Alamos, NM; Grace, Karen M [Los Alamos, NM; Grace, Wynne K [Los Alamos, NM; Shreve, Andrew P [Santa Fe, NM
2009-06-02
An assay element is described including recognition ligands bound to a film on a single mode planar optical waveguide, the film from the group of a membrane, a polymerized bilayer membrane, and a self-assembled monolayer containing polyethylene glycol or polypropylene glycol groups therein and an assay process for detecting the presence of a biological target is described including injecting a biological target-containing sample into a sensor cell including the assay element, with the recognition ligands adapted for binding to selected biological targets, maintaining the sample within the sensor cell for time sufficient for binding to occur between selected biological targets within the sample and the recognition ligands, injecting a solution including a reporter ligand into the sensor cell; and, interrogating the sample within the sensor cell with excitation light from the waveguide, the excitation light provided by an evanescent field of the single mode penetrating into the biological target-containing sample to a distance of less than about 200 nanometers from the waveguide thereby exciting the fluorescent-label in any bound reporter ligand within a distance of less than about 200 nanometers from the waveguide and resulting in a detectable signal.
Martinez, Jennifer S [Santa Fe, NM; Swanson, Basil I [Los Alamos, NM; Shively, John E [Arcadia, CA; Li, Lin [Monrovia, CA
2009-06-02
An assay element is described including recognition ligands adapted for binding to carcinoembryonic antigen (CEA) bound to a film on a single mode planar optical waveguide, the film from the group of a membrane, a polymerized bilayer membrane, and a self-assembled monolayer containing polyethylene glycol or polypropylene glycol groups therein and an assay process for detecting the presence of CEA is described including injecting a possible CEA-containing sample into a sensor cell including the assay element, maintaining the sample within the sensor cell for time sufficient for binding to occur between CEA present within the sample and the recognition ligands, injecting a solution including a reporter ligand into the sensor cell; and, interrogating the sample within the sensor cell with excitation light from the waveguide, the excitation light provided by an evanescent field of the single mode penetrating into the biological target-containing sample to a distance of less than about 200 nanometers from the waveguide thereby exciting any bound reporter ligand within a distance of less than about 200 nanometers from the waveguide and resulting in a detectable signal.
NASA Astrophysics Data System (ADS)
Kegerise, Michael A.; Rufer, Shann J.
2016-08-01
In this paper, we report on the application of the atomic layer thermopile (ALTP) heat-flux sensor to the measurement of laminar-to-turbulent transition in a hypersonic flat-plate boundary layer. The centerline of the flat-plate model was instrumented with a streamwise array of ALTP sensors, and the flat-plate model was exposed to a Mach 6 freestream over a range of unit Reynolds numbers. Here, we observed an unstable band of frequencies that are associated with second-mode instability waves in the laminar boundary layer that forms on the flat-plate surface. The measured frequencies, group velocities, phase speeds, and wavelengths of these instability waves are consistent with data previously reported in the literature. Heat flux time series, and the Morlet wavelet transforms of them, revealed the wave-packet nature of the second-mode instability waves. In addition, a laser-based radiative heating system was used to measure the frequency response functions (FRF) of the ALTP sensors used in the wind tunnel test. These measurements were used to assess the stability of the sensor FRFs over time and to correct spectral estimates for any attenuation caused by the finite sensor bandwidth.
NASA Astrophysics Data System (ADS)
Savoy, Steven M.; Lavigne, John J.; Yoo, J. S.; Wright, John; Rodriguez, Marc; Goodey, Adrian; McDoniel, Bridget; McDevitt, John T.; Anslyn, Eric V.; Shear, Jason B.; Ellington, Andrew D.; Neikirk, Dean P.
1998-12-01
A micromachined sensor array has been developed for the rapid characterization of multi-component mixtures in aqueous media. The sensor functions in a manner analogous to that of the mammalian tongue, using an array composed of individually immobilized polystyrene-polyethylene glycol composite microspheres selectively arranged in micromachined etch cavities localized o n silicon wafers. Sensing occurs via colorimetric or fluorometric changes to indicator molecules that are covalently bound to amine termination sites on the polymeric microspheres. The hybrid micromachined structure has been interfaced directly to a charged-coupled-device that is used for the simultaneous acquisition of the optical data from the individually addressable `taste bud' elements. With the miniature sensor array, acquisition of data streams composed of red, green, and blue color patterns distinctive for the analytes in the solution are rapidly acquired. The unique combination of carefully chosen reporter molecules with water permeable microspheres allows for the simultaneous detection and quantification of a variety of analytes. The fabrication of the sensor structures and the initial colorimetric and fluorescent responses for pH, Ca+2, Ce+3, and sugar are reported. Interface to microfluidic components should also be possible, producing a complete sampling/sensing system.
Tatsuno, Ichiro; Isaka, Masanori; Okada, Ryo; Zhang, Yan; Hasegawa, Tadao
2014-03-28
The production of virulence proteins depends on environmental factors, and two-component regulatory systems are involved in sensing these factors. We previously established knockout strains in all suspected two-component regulatory sensor proteins of the emm1 clinical strain of S. pyogenes and examined their relevance to acid stimuli in a natural atmosphere. In the present study, their relevance to acid stimuli was re-examined in an atmosphere containing 5% CO2. The spy1236 (which is identical to ciaHpy) sensor knockout strain showed significant growth reduction compared with the parental strain in broth at pH 6.0, suggesting that the Spy1236 (CiaHpy) two-component sensor protein is involved in acid response of S. pyogenes. CiaH is also conserved in Streptococcus pneumoniae, and it has been reported that deletion of the gene for its cognate response regulator (ciaRpn) made the pneumococcal strains more sensitive to oxidative stress. In this report, we show that the spy1236 knockout mutant of S. pyogenes is more sensitive to oxidative stress than the parental strain. These results suggest that the two-component sensor protein CiaH is involved in stress responses in S. pyogenes.
Test Report for NG Sensors GTX-1000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manginell, Ronald P.
2014-12-01
This report describes initial testing of the NG Sensor GTX-1000 natural gas monitoring system. This testing showed that the retention time, peak area stability and heating value repeatability of the GTX-1000 were promising for natural gas measurements in the field or at the well head. The repeatability can be less than 0.25% for LHV and HHV for the Airgas standard tested in this report, which is very promising for a first generation prototype. Ultimately this system should be capable of 0.1% repeatability in heating value at significant size and power reductions compared with competing systems.
NASA Astrophysics Data System (ADS)
Baldoli, Ilaria; Maselli, Martina; Cecchi, Francesca; Laschi, Cecilia
2017-10-01
Matrix textile sensors hold great potential for measuring pressure distribution in applications of modern daily lives, mainly regarding the biomedical field, but also robotics, automotive systems, and wearable and consumer electronics. However, an experimental analysis of their metrological properties is lacking in the literature, thus compromising their widespread acceptance. In the present work, we report the characterization of an 8 × 8 textile sensor assembled by sandwiching a piezoresistive fabric sheet between two outer fabric layers embedding conductive rows and columns. The location of the applied pressure can be identified by detecting the position where the change of resistances occurs between the external conductive paths. The sensor structure, its electrical circuit and characteristics are described in detail, after studying both the integration levels of the hierarchical structure and the composition of the piezoresistive fabric sheet. The pressure measurement range and the calibration curve were studied by tuning circuital parameters. Repeatability, time drift, temperature dependence, signal-to-noise ratio and dynamic response were analyzed. Novel tests were employed to consider the sensor sensitivity to stretch, shear force and surface curvature. A special analysis was taken over hysteresis and dynamic accuracy, focusing on a possible compensating solution. Results indicated that the system provides overall good quality performances with the main drawback of a limited dynamic accuracy, typical of piezoresistive sensing elements. Nevertheless, the use of textiles allows the realization of lightweight, wearable, washable, thin and stretchable sensors. In addition fabric sensors are robust, cheap, easy-to-use and employable to cover large area three dimensional surfaces. The wide characterization reported here could provide precious insights and guidelines to help researchers and users in taking advantages from all of these benefits, supporting them in choosing the best sensor design and application.
DOT National Transportation Integrated Search
1997-08-27
The work accomplished under this initiative is in direct relation to the development effort proposed by Spectra : Research, Inc. (S*R) for an "Off-Road Axle Detection Sensor (ORADS)". The feasibility study was performed to : investigate potential occ...
Open-Path Hydrocarbon Laser Sensor for Oil and Gas Facility Monitoring
This poster reports on an experimental prototype open-path laser absorption sensor for measurement of unspeciated hydrocarbons for oil and gas production facility fence-line monitoring. Such measurements may be useful to meet certain state regulations, and enable advanced leak d...
Low-Power RF SOI-CMOS Technology for Distributed Sensor Networks
NASA Technical Reports Server (NTRS)
Dogan, Numan S.
2003-01-01
The objective of this work is to design and develop Low-Power RF SOI-CMOS Technology for Distributed Sensor Networks. We briefly report on the accomplishments in this work. We also list the impact of this work on graduate student research training/involvement.
Development of collision avoidance for light vehicles : near-crash/crash event data recorders
DOT National Transportation Integrated Search
2006-12-01
This report presents the results of an analysis effort undertaken to address the following research question: What sensor(s) can be cost effectively added to vehicles on a wide scale to significantly improve the understanding and modeling of naturali...
Model 0102 Flat Plate Antenna for Use in Automobile Radar Anticipatory Crash Sensors
DOT National Transportation Integrated Search
1973-09-01
The report analyzed alternative methods of construction and production costs for a flat plate antenna based on the use of etched circuit techniques. The antenna is proposed for use in certain new automotive radar anticipatory crash sensor systems now...
FogEye UV Sensor System : Low Visibility Landing Test (Phase IV Report)
DOT National Transportation Integrated Search
2004-03-01
The potential of FogEye solar blind UV technology to contribute to safe and swift throughput operations at airports has been demonstrated. One application, use of FogEye (Safety Sentry), as an aircraft surface detection sensor has been successfully o...
South Philadelphia Passive Sampler and Sensor Study - Interim Report
Starting in the June 2013, the U.S. EPA and the City of Philadelphia Air Measurements Services (AMS) began a collaborative research project to investigate how sensor-based, stand-alone air measurements (SAMs) and passive samplers (PSs) can help improve information on air pollutan...
Development of sensors for ceramic components in advanced propulsion systems
NASA Technical Reports Server (NTRS)
Atkinson, William H.; Cyr, M. A.; Strange, R. R.
1994-01-01
The 'Development of Sensors for Ceramics Components in Advanced Propulsion Systems' program was divided into two phases. The objectives of Phase 1 were to analyze, evaluate and recommend sensor concepts for the measurement of surface temperature, strain and heat flux on ceramic components for advanced propulsion systems. The results of this effort were previously published in NASA CR-182111. As a result of Phase 1, three approaches were recommended for further development: pyrometry, thin-film sensors, and thermographic phosphors. The objectives of Phase 2 were to fabricate and conduct laboratory demonstration tests of these systems. A summary report of the Phase 2 effort, together with conclusions and recommendations for each of the categories evaluated, has been submitted to NASA. Emittance tests were performed on six materials furnished by NASA Lewis Research Center. Measurements were made of various surfaces at high temperature using a Thermogage emissometer. This report describes the emittance test program and presents a summary of the results.
A survey of atmospheric monitoring systems in U.S. underground coal mines
Rowland, J.H.; Harteis, S.P.; Yuan, L.
2018-01-01
In 1995 and 2003, the U.S. Mine Safety and Health Administration (MSHA) conducted surveys to determine the number of atmospheric monitoring systems (AMS) that were being used in underground coal mines in the United States. The survey reports gave data for the different AMS manufacturers, the different types of equipment monitored, and the different types of gas sensors and their locations. Since the last survey in 2003, MSHA has changed the regulation requirements for early fire detection along belt haulage entries. As of Dec. 31, 2009, point-type heat sensors are prohibited for use for an early fire detection system. Instead, carbon monoxide (CO) sensors are now required. This report presents results from a new survey and examines how the regulation changes have had an impact on the use of CO sensors in underground coal mines in the United States. The locations and parameters monitored by AMS and CO systems are also discussed. PMID:29674789
Quantum Field Energy Sensor based on the Casimir Effect
NASA Astrophysics Data System (ADS)
Ludwig, Thorsten
The Casimir effect converts vacuum fluctuations into a measurable force. Some new energy technologies aim to utilize these vacuum fluctuations in commonly used forms of energy like electricity or mechanical motion. In order to study these energy technologies it is helpful to have sensors for the energy density of vacuum fluctuations. In today's scientific instrumentation and scanning microscope technologies there are several common methods to measure sub-nano Newton forces. While the commercial atomic force microscopes (AFM) mostly work with silicon cantilevers, there are a large number of reports on the use of quartz tuning forks to get high-resolution force measurements or to create new force sensors. Both methods have certain advantages and disadvantages over the other. In this report the two methods are described and compared towards their usability for Casimir force measurements. Furthermore a design for a quantum field energy sensor based on the Casimir force measurement will be described. In addition some general considerations on extracting energy from vacuum fluctuations will be given.
Development of optical MEMS CO2 sensors
NASA Astrophysics Data System (ADS)
McNeal, Mark P.; Moelders, Nicholas; Pralle, Martin U.; Puscasu, Irina; Last, Lisa; Ho, William; Greenwald, Anton C.; Daly, James T.; Johnson, Edward A.; George, Thomas
2002-09-01
Inexpensive optical MEMS gas and chemical sensors offer chip-level solutions to environmental monitoring, industrial health and safety, indoor air quality, and automobile exhaust emissions monitoring. Previously, Ion Optics, Inc. reported on a new design concept exploiting Si-based suspended micro-bridge structures. The devices are fabricated using conventional CMOS compatible processes. The use of photonic bandgap (PBG) crystals enables narrow band IR emission for high chemical selectivity and sensitivity. Spectral tuning was accomplished by controlling symmetry and lattice spacing of the PBG structures. IR spectroscopic studies were used to characterize transmission, absorption and emission spectra in the 2 to 20 micrometers wavelength range. Prototype designs explored suspension architectures and filament geometries. Device characterization studies measured drive and emission power, temperature uniformity, and black body detectivity. Gas detection was achieved using non-dispersive infrared (NDIR) spectroscopic techniques, whereby target gas species were determined from comparison to referenced spectra. A sensor system employing the emitter/detector sensor-chip with gas cell and reflective optics is demonstrated and CO2 gas sensitivity limits are reported.
Sensitive determination of citrinin based on molecular imprinted electrochemical sensor
NASA Astrophysics Data System (ADS)
Atar, Necip; Yola, Mehmet Lütfi; Eren, Tanju
2016-01-01
In this report, a novel molecular imprinted voltammetric sensor based on glassy carbon electrode (GCE) modified with platinum nanoparticles (PtNPs) involved in a polyoxometalate (H3PW12O40, POM) functionalized reduced graphene oxide (rGO) was prepared for the determination of citrinin (CIT). The developed surfaces were characterized by using scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) method. CIT imprinted GCE was prepared via electropolymerization process of 80.0 mM pyrrole as monomer in the presence of phosphate buffer solution (pH 6.0) containing 20.0 mM CIT. The linearity range and the detection limit of the developed method were calculated as 1.0 × 10-12-1.0 × 10-10 M and 2.0 × 10-13 M, respectively. In addition, the voltammetric sensor was applied to rye samples. The stability and selectivity of the voltammetric sensor were also reported.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Lei, E-mail: donglei@sxu.edu.cn; State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006; Li, Chunguang
A tunable diode laser absorption spectroscopy-based methane sensor, employing a dense-pattern multi-pass gas cell and a 3.3 μm, CW, DFB, room temperature interband cascade laser (ICL), is reported. The optical integration based on an advanced folded optical path design and an efficient ICL control system with appropriate electrical power management resulted in a CH{sub 4} sensor with a small footprint (32 × 20 × 17 cm{sup 3}) and low-power consumption (6 W). Polynomial and least-squares fit algorithms are employed to remove the baseline of the spectral scan and retrieve CH{sub 4} concentrations, respectively. An Allan-Werle deviation analysis shows that the measurement precision can reach 1.4 ppb for amore » 60 s averaging time. Continuous measurements covering a seven-day period were performed to demonstrate the stability and robustness of the reported CH{sub 4} sensor system.« less
New molecular imprinted voltammetric sensor for determination of ochratoxin A.
Yola, Mehmet Lütfi; Gupta, Vinod Kumar; Atar, Necip
2016-04-01
In this report, a novel molecular imprinted voltammetric sensor based on silver nanoparticles (AgNPs) involved in a polyoxometalate (H3PW12O40, POM) functionalized reduced graphene oxide (rGO) modified glassy carbon electrode (GCE) was presented for determination of ochrattoxin A (OCH). The developed surfaces were characterized using scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) method. OCH imprinted GCE was prepared via electropolymerization process of 100mM phenol as monomer in the presence of phosphate buffer solution (pH6.0) containing 25 mM OCH. The linearity range and the detection limit of the method were calculated as 5.0 × 10(-11) - 1.5 × 10(-9)M and 1.6 × 10(-11) M, respectively. The voltammetric sensor was applied to grape juice and wine samples with good selectivity and recovery. The stability of the voltammetric sensor was also reported. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.
2018-03-01
Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.
Estimating the Probability of a Diffusing Target Encountering a Stationary Sensor.
1985-07-01
7 RD-R1577 6- 44 ESTIMATING THE PROBABILITY OF A DIFFUSING TARGET i/i ENCOUNTERING R STATIONARY SENSOR(U) NAVAL POSTGRADUATE U SCHOOL MONTEREY CA...8217,: *.:.; - -*.. ,’.-,:;;’.’.. ’,. ,. .*.’.- 4 6 6- ..- .-,,.. : .-.;.- -. NPS55-85-013 NAVAL POSTGRADUATE SCHOOL Monterey, California ESTIMATING THE PROBABILITY OF A DIFFUSING TARGET...PROBABILITY OF A DIFFUSING Technical TARGET ENCOUNTERING A STATIONARY SENSOR S. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(@) S. CONTRACT OR GRANT NUMBER(a
2015-04-07
ships, equipped with advanced anti-ship, anti- air, and anti-submarine weapons and sensors . Whereas “near seas” defense remains the PLA Navy’s...that “destroying or capturing satellites and other sensors … will deprive an opponent of initiative on the battlefield and [make it difficult] for...aircraft are modern avionics and sensors that offer more timely situational awareness for operations in network-centric combat environments, radars
Studies to design and develop improved remote manipulator systems
NASA Technical Reports Server (NTRS)
Hill, J. W.; Sword, A. J.
1973-01-01
Remote manipulator control considered is based on several levels of automatic supervision which derives manipulator commands from an analysis of sensor states and task requirements. Principle sensors are manipulator joint position, tactile, and currents. The tactile sensor states can be displayed visually in perspective or replicated in the operator's control handle of perceived by the automatic supervisor. Studies are reported on control organization, operator performance and system performance measures. Unusual hardware and software details are described.
2009-08-20
Nomenclature As = QCM sensor area E = ion energy E* = characteristic energy describing the differential sputter yield profile shape Eth...We report differential and total sputter yields for several grades of BN at ion energies down to 60 eV, obtained with a QCM deposition sensor 3-7,9...personal computer with LabView is used for data logging. Detailed discussion of the QCM sensor is provided in subsection IIF. B. Definition of Angles
Mani, Ganesh Kumar; Miyakoda, Kousei; Saito, Asuka; Yasoda, Yutaka; Kajiwara, Kagemasa; Kimura, Minoru; Tsuchiya, Kazuyoshi
2017-07-05
Acid-base homeostasis (body pH) inside the body is precisely controlled by the kidneys and lungs and buffer systems, such that even a minor pH change could severely affect many organs. Blood and urine pH tests are common in day-to-day clinical trials and require little effort for diagnosis. There is always a great demand for in vivo testing to understand more about body metabolism and to provide effective diagnosis and therapy. In this article, we report the simple fabrication of microneedle-based direct, label-free, and real-time pH sensors. The reference and working electrodes were Ag/AgCl thick films and ZnO thin films on tungsten (W) microneedles, respectively. The morphological and structural characteristics of microneedles were carefully investigated through various analytical methods. The developed sensor exhibited a Nernstian response of -46 mV/pH. Different conditions were used to test the sensor to confirm their accuracy and stability, such as various buffer solutions, with respect to time, and we compared the reading with commercial pH electrodes. Besides that, the fabricated microneedle sensor ability is proven by in vivo testing in mouse cerebrospinal fluid (CSF) and bladders. The pH sensor procedure reported here is totally reversible, and results were reproducible after several rounds of testing.
Deep-Sea DuraFET: A Pressure Tolerant pH Sensor Designed for Global Sensor Networks.
Johnson, Kenneth S; Jannasch, Hans W; Coletti, Luke J; Elrod, Virginia A; Martz, Todd R; Takeshita, Yuichiro; Carlson, Robert J; Connery, James G
2016-03-15
Increasing atmospheric carbon dioxide is driving a long-term decrease in ocean pH which is superimposed on daily to seasonal variability. These changes impact ecosystem processes, and they serve as a record of ecosystem metabolism. However, the temporal variability in pH is observed at only a few locations in the ocean because a ship is required to support pH observations of sufficient precision and accuracy. This paper describes a pressure tolerant Ion Sensitive Field Effect Transistor pH sensor that is based on the Honeywell Durafet ISFET die. When combined with a AgCl pseudoreference sensor that is immersed directly in seawater, the system is capable of operating for years at a time on platforms that cycle from depths of several km to the surface. The paper also describes the calibration scheme developed to allow calibrated pH measurements to be derived from the activity of HCl reported by the sensor system over the range of ocean pressure and temperature. Deployments on vertical profiling platforms enable self-calibration in deep waters where pH values are stable. Measurements with the sensor indicate that it is capable of reporting pH with an accuracy of 0.01 or better on the total proton scale and a precision over multiyear periods of 0.005. This system enables a global ocean observing system for ocean pH.
MOF-Based Membrane Encapsulated ZnO Nanowires for Enhanced Gas Sensor Selectivity.
Drobek, Martin; Kim, Jae-Hun; Bechelany, Mikhael; Vallicari, Cyril; Julbe, Anne; Kim, Sang Sub
2016-04-06
Gas sensors are of a great interest for applications including toxic or explosive gases detection in both in-house and industrial environments, air quality monitoring, medical diagnostics, or control of food/cosmetic properties. In the area of semiconductor metal oxides (SMOs)-based sensors, a lot of effort has been devoted to improve the sensing characteristics. In this work, we report on a general methodology for improving the selectivity of SMOx nanowires sensors, based on the coverage of ZnO nanowires with a thin ZIF-8 molecular sieve membrane. The optimized ZnO@ZIF-8-based nanocomposite sensor shows markedly selective response to H2 in comparison with the pristine ZnO nanowires sensor, while showing the negligible sensing response to C7H8 and C6H6. This original MOF-membrane encapsulation strategy applied to nanowires sensor architecture pave the way for other complex 3D architectures and various types of applications requiring either gas or ion selectivity, such as biosensors, photo(catalysts), and electrodes.
Enhanced In-Pile Instrumentation at the Advanced Test Reactor
NASA Astrophysics Data System (ADS)
Rempe, Joy L.; Knudson, Darrell L.; Daw, Joshua E.; Unruh, Troy; Chase, Benjamin M.; Palmer, Joe; Condie, Keith G.; Davis, Kurt L.
2012-08-01
Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper provides an update on this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and real-time flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted.
Reduced signal crosstalk multi neurotransmitter image sensor by microhole array structure
NASA Astrophysics Data System (ADS)
Ogaeri, Yuta; Lee, You-Na; Mitsudome, Masato; Iwata, Tatsuya; Takahashi, Kazuhiro; Sawada, Kazuaki
2018-06-01
A microhole array structure combined with an enzyme immobilization method using magnetic beads can enhance the target discernment capability of a multi neurotransmitter image sensor. Here we report the fabrication and evaluation of the H+-diffusion-preventing capability of the sensor with the array structure. The structure with an SU-8 photoresist has holes with a size of 24.5 × 31.6 µm2. Sensors were prepared with the array structure of three different heights: 0, 15, and 60 µm. When the sensor has the structure of 60 µm height, 48% reduced output voltage is measured at a H+-sensitive null pixel that is located 75 µm from the acetylcholinesterase (AChE)-immobilized pixel, which is the starting point of H+ diffusion. The suppressed H+ immigration is shown in a two-dimensional (2D) image in real time. The sensor parameters, such as height of the array structure and measuring time, are optimized experimentally. The sensor is expected to effectively distinguish various neurotransmitters in biological samples.
Au-Graphene Hybrid Plasmonic Nanostructure Sensor Based on Intensity Shift
Alharbi, Raed; Irannejad, Mehrdad; Yavuz, Mustafa
2017-01-01
Integrating plasmonic materials, like gold with a two-dimensional material (e.g., graphene) enhances the light-material interaction and, hence, plasmonic properties of the metallic nanostructure. A localized surface plasmon resonance sensor is an effective platform for biomarker detection. They offer a better bulk surface (local) sensitivity than a regular surface plasmon resonance (SPR) sensor; however, they suffer from a lower figure of merit compared to that one in a propagating surface plasmon resonance sensors. In this work, a decorated multilayer graphene film with an Au nanostructures was proposed as a liquid sensor. The results showed a significant improvement in the figure of merit compared with other reported localized surface plasmon resonance sensors. The maximum figure of merit and intensity sensitivity of 240 and 55 RIU−1 (refractive index unit) at refractive index change of 0.001 were achieved which indicate the capability of the proposed sensor to detect a small change in concentration of liquids in the ng/mL level which is essential in early-stage cancer disease detection. PMID:28106850
Herrmann, E; Fichtlscherer, S; Hohnloser, S H; Zeiher, A M; Aßmus, B
2016-12-01
Patients with advanced heart failure suffer from frequent hospitalizations. Non-invasive hemodynamic telemonitoring for assessment of ventricular filling pressure has been shown to reduce hospitalizations. We report on the right ventricular (RVP), the pulmonary artery (PAP) and the left atrial pressure (LAP) sensor for non-invasive assessment of the ventricular filling pressure. A literature search concerning the available implantable pressure sensors for noninvasive haemodynamic telemonitoring in patients with advanced heart failure was performed. Until now, only implantation of the PAP-sensor was able to reduce hospitalizations for cardiac decompensation and to improve quality of life. The right ventricular pressure sensor missed the primary endpoint of a significant reduction of hospitalizations, clinical data using the left atrial pressure sensor are still pending. The implantation of a pressure sensor for assessment of pulmonary artery filling pressure is suitable for reducing hospitalizations for heart failure and for improving quality of life in patients with advanced heart failure.
Monitoring of Vital Signs with Flexible and Wearable Medical Devices.
Khan, Yasser; Ostfeld, Aminy E; Lochner, Claire M; Pierre, Adrien; Arias, Ana C
2016-06-01
Advances in wireless technologies, low-power electronics, the internet of things, and in the domain of connected health are driving innovations in wearable medical devices at a tremendous pace. Wearable sensor systems composed of flexible and stretchable materials have the potential to better interface to the human skin, whereas silicon-based electronics are extremely efficient in sensor data processing and transmission. Therefore, flexible and stretchable sensors combined with low-power silicon-based electronics are a viable and efficient approach for medical monitoring. Flexible medical devices designed for monitoring human vital signs, such as body temperature, heart rate, respiration rate, blood pressure, pulse oxygenation, and blood glucose have applications in both fitness monitoring and medical diagnostics. As a review of the latest development in flexible and wearable human vitals sensors, the essential components required for vitals sensors are outlined and discussed here, including the reported sensor systems, sensing mechanisms, sensor fabrication, power, and data processing requirements. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
TinyOS-based quality of service management in wireless sensor networks
Peterson, N.; Anusuya-Rangappa, L.; Shirazi, B.A.; Huang, R.; Song, W.-Z.; Miceli, M.; McBride, D.; Hurson, A.; LaHusen, R.
2009-01-01
Previously the cost and extremely limited capabilities of sensors prohibited Quality of Service (QoS) implementations in wireless sensor networks. With advances in technology, sensors are becoming significantly less expensive and the increases in computational and storage capabilities are opening the door for new, sophisticated algorithms to be implemented. Newer sensor network applications require higher data rates with more stringent priority requirements. We introduce a dynamic scheduling algorithm to improve bandwidth for high priority data in sensor networks, called Tiny-DWFQ. Our Tiny-Dynamic Weighted Fair Queuing scheduling algorithm allows for dynamic QoS for prioritized communications by continually adjusting the treatment of communication packages according to their priorities and the current level of network congestion. For performance evaluation, we tested Tiny-DWFQ, Tiny-WFQ (traditional WFQ algorithm implemented in TinyOS), and FIFO queues on an Imote2-based wireless sensor network and report their throughput and packet loss. Our results show that Tiny-DWFQ performs better in all test cases. ?? 2009 IEEE.
NASA Technical Reports Server (NTRS)
Caglayan, A. K.; Godiwala, P. M.
1985-01-01
The performance analysis results of a fault inferring nonlinear detection system (FINDS) using sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment is presented. First, a statistical analysis of the flight recorded sensor data was made in order to determine the characteristics of sensor inaccuracies. Next, modifications were made to the detection and decision functions in the FINDS algorithm in order to improve false alarm and failure detection performance under real modelling errors present in the flight data. Finally, the failure detection and false alarm performance of the FINDS algorithm were analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minute flight data. In general, the detection speed, failure level estimation, and false alarm performance showed a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed was faster for filter measurement sensors soon as MLS than for filter input sensors such as flight control accelerometers.
Flight Hydrogen Sensor for use in the ISS Oxygen Generation Assembly
NASA Technical Reports Server (NTRS)
MSadoques, George, Jr.; Makel, Darby B.
2005-01-01
This paper provides a description of the hydrogen sensor Orbital Replacement Unit (ORU) used on the Oxygen Generation Assembly (OGA), to be operated on the International Space Station (ISS). The hydrogen sensor ORU is being provided by Makel Engineering, Inc. (MEI) to monitor the oxygen outlet for the presence of hydrogen. The hydrogen sensor ORU is a triple redundant design where each sensor converts raw measurements to actual hydrogen partial pressure that is reported to the OGA system controller. The signal outputs are utilized for system shutdown in the event that the hydrogen concentration in the oxygen outlet line exceeds the specified shutdown limit. Improvements have been made to the Micro-Electro-Mechanical Systems (MEMS) based sensing element, screening, and calibration process to meet OGA operating requirements. Two flight hydrogen sensor ORUs have successfully completed the acceptance test phase. This paper also describes the sensor s performance during acceptance testing, additional tests planned to extend the operational performance calibration cycle, and integration with the OGA system.
Sensor Compendium - A Snowmass Whitepaper-
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artuso, M.; Battaglia, M.; Bolla, G.
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In additionmore » the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges.« less
Nitric Oxide Release for Improving Performance of Implantable Chemical Sensors - A Review.
Cha, Kyoung Ha; Wang, Xuewei; Meyerhoff, Mark E
2017-12-01
Over the last three decades, there has been extensive interest in developing in vivo chemical sensors that can provide real-time measurements of blood gases (oxygen, carbon dioxide, and pH), glucose/lactate, and potentially other critical care analytes in the blood of hospitalized patients. However, clot formation with intravascular sensors and foreign body response toward sensors implanted subcutaneously can cause inaccurate analytical results. Further, the risk of bacterial infection from any sensor implanted in the human body is another major concern. To solve these issues, the release of an endogenous gas molecule, nitric oxide (NO), from the surface of such sensors has been investigated owing to NO's ability to inhibit platelet activation/adhesion, foreign body response and bacterial growth. This paper summarizes the importance of NO's therapeutic potential for this application and reviews the publications to date that report on the analytical performance of NO release sensors in laboratory testing and/or during in vivo testing.
Lightweight Fiber Optic Gas Sensor for Monitoring Regenerative Food Production
NASA Technical Reports Server (NTRS)
Schmidlin, Edward; Goswami, Kisholoy
1995-01-01
In this final report, Physical Optics Corporation (POC) describes its development of sensors for oxygen, carbon dioxide, and relative humidity. POC has constructed a phase fluorometer that can detect oxygen over the full concentration range from 0 percent to 100 percent. Phase-based measurements offer distinct advantages, such as immunity to source fluctuation, photobleaching, and leaching. All optics, optoelectronics, power supply, and the printed circuit board are included in a single box; the only external connections to the fluorometer are the optical fiber sensor and a power cord. The indicator-based carbon dioxide sensor is also suitable for short-term and discrete measurements over the concentration range from 0 percent to 100 percent. The optical fiber-based humidity sensor contains a porous core for direct interaction of the light beam with water vapor within fiber pores; the detection range for the humidity sensor is 10 percent to 100 percent, and response time is under five minutes. POC is currently pursuing the commercialization of these oxygen and carbon dioxide sensors for environmental applications.
Germond, Arno; Fujita, Hideaki; Ichimura, Taro; Watanabe, Tomonobu M
Over the past decades many researchers have made major contributions towards the development of genetically encoded (GE) fluorescent sensors derived from fluorescent proteins. GE sensors are now used to study biological phenomena by facilitating the measurement of biochemical behaviors at various scales, ranging from single molecules to single cells or even whole animals. Here, we review the historical development of GE fluorescent sensors and report on their current status. We specifically focus on the development strategies of the GE sensors used for measuring pH, ion concentrations (e.g., chloride and calcium), redox indicators, membrane potential, temperature, pressure, and molecular crowding. We demonstrate that these fluroescent protein-based sensors have a shared history of concepts and development strategies, and we highlight the most original concepts used to date. We believe that the understanding and application of these various concepts will pave the road for the development of future GE sensors and lead to new breakthroughs in bioimaging.
Germond, Arno; Fujita, Hideaki; Ichimura, Taro; Watanabe, Tomonobu M
2016-06-01
Over the past decades many researchers have made major contributions towards the development of genetically encoded (GE) fluorescent sensors derived from fluorescent proteins. GE sensors are now used to study biological phenomena by facilitating the measurement of biochemical behaviors at various scales, ranging from single molecules to single cells or even whole animals. Here, we review the historical development of GE fluorescent sensors and report on their current status. We specifically focus on the development strategies of the GE sensors used for measuring pH, ion concentrations (e.g., chloride and calcium), redox indicators, membrane potential, temperature, pressure, and molecular crowding. We demonstrate that these fluroescent protein-based sensors have a shared history of concepts and development strategies, and we highlight the most original concepts used to date. We believe that the understanding and application of these various concepts will pave the road for the development of future GE sensors and lead to new breakthroughs in bioimaging.
Single Walled Carbon Nanotube Based Air Pocket Encapsulated Ultraviolet Sensor.
Kim, Sun Jin; Han, Jin-Woo; Kim, Beomseok; Meyyappan, M
2017-11-22
Carbon nanotube (CNT) is a promising candidate as a sensor material for the sensitive detection of gases/vapors, biomarkers, and even some radiation, as all these external variables affect the resistance and other properties of nanotubes, which forms the basis for sensing. Ultraviolet (UV) radiation does not impact the nanotube properties given the substantial mismatch of bandgaps and therefore, CNTs have never been considered for UV sensing, unlike the popular ZnO and other oxide nanwires. It is well-known that UV assists the adsorption/desorption characteristics of oxygen on carbon nanotubes, which changes the nanotube resistance. Here, we demonstrate a novel sensor structure encapsulated with an air pocket, where the confined air is responsible for the UV sensing mechanism and assures sensor stability and repeatability over time. In addition to the protection from any contamination, the air pocket encapsulated sensor offers negligible baseline drift and fast recovery compared to previously reported sensors. The air pocket isolated from the outside environment can act as a stationary oxygen reservoir, resulting in consistent sensor characteristics. Furthermore, this sensor can be used even in liquid environments.
Self-Test Procedures for Gas Sensors Embedded in Microreactor Systems
Helwig, Andreas; Hackner, Angelika; Zappa, Dario; Sberveglieri, Giorgio
2018-01-01
Metal oxide (MOX) gas sensors sensitively respond to a wide variety of combustible, explosive and poisonous gases. However, due to the lack of a built-in self-test capability, MOX gas sensors have not yet been able to penetrate safety-critical applications. In the present work we report on gas sensing experiments performed on MOX gas sensors embedded in ceramic micro-reaction chambers. With the help of an external micro-pump, such systems can be operated in a periodic manner alternating between flow and no-flow conditions, thus allowing repetitive measurements of the sensor resistances under clean air, R0, and under gas exposure, Rgas, to be obtained, even under field conditions. With these pairs of resistance values, eventual drifts in the sensor baseline resistance can be detected and drift-corrected values of the relative resistance response Resp=(R0−Rgas)/R0 can be determined. Residual poisoning-induced changes in the relative resistance response can be detected by reference to humidity measurements taken with room-temperature-operated capacitive humidity sensors which are insensitive to the poisoning processes operative on heated MOX gas sensors. PMID:29401673
NASA Astrophysics Data System (ADS)
Sharma, Anuj K.; Kaur, Baljinder
2018-07-01
Surface plasmon resonance (SPR) based chalcogenide fiber-optic sensor with polymer clad and MoS2 monolayer is simulated and analyzed in near infrared (NIR) for detection of mixture of alcohols (ethanol and methanol) dissolved in water solution. The proposed fiber optic sensor is analyzed under angular interrogation method, which is based on selective ray (on-axis) launching of monochromatic light into the fiber core at varying angle followed by measuring the loss of power (in dB) after passing through the SPR probe region. The performance of the sensor is analyzed in terms of its figure of merit (FOM). The sensor's specificity towards alcohols along with considerably larger FOM is achieved by utilizing a polythiophene (PT) layer. The results indicate that longer NIR wavelength (λ) provides superior sensing performance. The sensor's performance is better for larger volume fraction of methanol in the water solution. The proposed fiber optic SPR sensor has the capability of providing much greater FOM compared with the previously-reported SPR sensors.
Jaisutti, Rawat; Kim, Jaeyoung; Park, Sung Kyu; Kim, Yong-Hoon
2016-08-10
We report on highly stable amorphous indium-gallium-zinc oxide (IGZO) gas sensors for ultraviolet (UV)-activated room-temperature detection of volatile organic compounds (VOCs). The IGZO sensors fabricated by a low-temperature photochemical activation process and exhibiting two orders higher photocurrent compared to conventional zinc oxide sensors, allowed high gas sensitivity against various VOCs even at room temperature. From a systematic analysis, it was found that by increasing the UV intensity, the gas sensitivity, response time, and recovery behavior of an IGZO sensor were strongly enhanced. In particular, under an UV intensity of 30 mW cm(-2), the IGZO sensor exhibited gas sensitivity, response time and recovery time of 37%, 37 and 53 s, respectively, against 750 ppm concentration of acetone gas. Moreover, the IGZO gas sensor had an excellent long-term stability showing around 6% variation in gas sensitivity over 70 days. These results strongly support a conclusion that a low-temperature solution-processed amorphous IGZO film can serve as a good candidate for room-temperature VOCs sensors for emerging wearable electronics.
Beam test of novel n-in-p strip sensors for high radiation environment
NASA Astrophysics Data System (ADS)
Kubota, T.; Kishida, T.; Jinnouchi, O.; Ikegami, Y.; Unno, Y.; Terada, S.; Mitsui, S.; Tamii, A.; Aoi, T.; Hanagaki, K.; Hara, K.; Kimura, N.; Takashima, R.; Takubo, Y.; Tojo, J.; Nagai, K.; Nakano, I.; Yorita, K.
2013-12-01
Highly radiation tolerant n-in-p strip sensors have been developed for the high-luminosity LHC (HL-LHC). This paper reports the results of measurements with 392 MeV kinetic energy proton beam at RCNP in December 2011. The data was taken with a new DAQ system consisting of an universal read-out board ‘SEABAS’ and beam tracking telescopes whose spacial resolution is better than 5 μm. The aim of this beam test is to evaluate the new 1 cm×1 cm n-in-p miniature sensors before and after 1015 neq cm-2 irradiation. The median charge of un-irradiated sensor is 6.2 fC at full depletion voltage, while the median charge after 1015 neq cm-2 irradiation of the sensor is 4.2 fC. The novel Punch-Through-Protection (PTP) has been implemented in these sensors. The length of active region of the sensor around PTP is observed to be decreased by 12 μm in the irradiated sensors at 1015 neq cm-2.
NASA Astrophysics Data System (ADS)
Guo, Xiaohui; Huang, Ying; Zhao, Yunong; Mao, Leidong; Gao, Le; Pan, Weidong; Zhang, Yugang; Liu, Ping
2017-09-01
Flexible, stretchable, and wearable strain sensors have attracted significant attention for their potential applications in human movement detection and recognition. Here, we report a highly stretchable and flexible strain sensor based on a single-walled carbon nanotube (SWCNTs)/carbon black (CB) synergistic conductive network. The fabrication, synergistic conductive mechanism, and characterization of the sandwich-structured strain sensor were investigated. The experimental results show that the device exhibits high stretchability (120%), excellent flexibility, fast response (˜60 ms), temperature independence, and superior stability and reproducibility during ˜1100 stretching/releasing cycles. Furthermore, human activities such as the bending of a finger or elbow and gestures were monitored and recognized based on the strain sensor, indicating that the stretchable strain sensor based on the SWCNTs/CB synergistic conductive network could have promising applications in flexible and wearable devices for human motion monitoring.
Advances in Multi-Sensor Information Fusion: Theory and Applications 2017.
Jin, Xue-Bo; Sun, Shuli; Wei, Hong; Yang, Feng-Bao
2018-04-11
The information fusion technique can integrate a large amount of data and knowledge representing the same real-world object and obtain a consistent, accurate, and useful representation of that object. The data may be independent or redundant, and can be obtained by different sensors at the same time or at different times. A suitable combination of investigative methods can substantially increase the profit of information in comparison with that from a single sensor. Multi-sensor information fusion has been a key issue in sensor research since the 1970s, and it has been applied in many fields. For example, manufacturing and process control industries can generate a lot of data, which have real, actionable business value. The fusion of these data can greatly improve productivity through digitization. The goal of this special issue is to report innovative ideas and solutions for multi-sensor information fusion in the emerging applications era, focusing on development, adoption, and applications.
Aurelia aurita bio-inspired tilt sensor
NASA Astrophysics Data System (ADS)
Smith, Colin; Villanueva, Alex; Priya, Shashank
2012-10-01
The quickly expanding field of mobile robots, unmanned underwater vehicles, and micro-air vehicles urgently needs a cheap and effective means for measuring vehicle inclination. Commonly, tilt or inclination has been mathematically derived from accelerometers; however, there is inherent error in any indirect measurement. This paper reports a bio-inspired tilt sensor that mimics the natural balance organ of jellyfish, called the ‘statocyst’. Biological statocysts from the species Aurelia aurita were characterized by scanning electron microscopy to investigate the morphology and size of the natural sensor. An artificial tilt sensor was then developed by using printed electronics that incorporates a novel voltage divider concept in conjunction with small surface mount devices. This sensor was found to have minimum sensitivity of 4.21° with a standard deviation of 1.77°. These results open the possibility of developing elegant tilt sensor architecture for both air and water based platforms.
Cuddy, Michael F; Poda, Aimee R; Brantley, Lauren N
2013-05-01
Isoelectric points (IEPs) were determined by the method of contact angle titration for five common quartz crystal microbalance (QCM) sensors. The isoelectric points range from mildly basic in the case of Al2O3 sensors (IEP = 8.7) to moderately acidic for Au (5.2) and SiO2 (3.9), to acidic for Ag (3.2) and Ti (2.9). In general, the values reported here are indicative of inherent surface oxides. A demonstration of the effect of the surface isoelectric point on the packing efficiency of thin mucin films is provided for gold and silica QCM sensors. It is determined that mucin layers on both substrates achieve a maximum and equal layer density of ∼3500 kg/m(3) at the corresponding IEP of either QCM sensor. This implies that mucin film packing is dependent upon short-range electrostatic interactions at the sensor surface.
A fiber-optic current sensor for aerospace applications
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Rose, A. H.; Tang, D.; Day, G. W.
1990-01-01
A robust, accurate, broadband, alternating current sensor using fiber optics is being developed for space applications at power frequencies as high as 20 kHz. It can also be used in low- and high-voltage 60-Hz terrestrial power systems and in 400-Hz aircraft systems. It is intrinsically EMI (electromagnetic interference) immune and has the added benefit of excellent isolation. The sensor uses the Faraday effect in optical fiber and standard polarimetric measurements to sense electrical current. The primary component of the sensor is a specially treated coil of single-mode optical fiber, through which the current carrying conductor passes. Improved precision is accomplished by temperature compensation by means of signals from a fiber-optic temperature sensor embedded in the sensing head. The authors report on the technology contained in the sensor and also relate the results of precision tests conducted at various temperatures within the wide operating range. The results of early EMI tests are shown.
Imaging extracellular ATP with a genetically-encoded, ratiometric fluorescent sensor
Conley, Jason M.
2017-01-01
Extracellular adenosine triphosphate (ATP) is a key purinergic signal that mediates cell-to-cell communication both within and between organ systems. We address the need for a robust and minimally invasive approach to measuring extracellular ATP by re-engineering the ATeam ATP sensor to be expressed on the cell surface. Using this approach, we image real-time changes in extracellular ATP levels with a sensor that is fully genetically-encoded and does not require an exogenous substrate. In addition, the sensor is ratiometric to allow for reliable quantitation of extracellular ATP fluxes. Using live-cell microscopy, we characterize sensor performance when expressed on cultured Neuro2A cells, and we measure both stimulated release of ATP and its clearance by ectonucleotidases. Thus, this proof-of-principle demonstrates a first-generation sensor to report extracellular ATP dynamics that may be useful for studying purinergic signaling in living specimens. PMID:29121644
High Temperature Capacitive Pressure Sensor Employing a SiC Based Ring Oscillator
NASA Technical Reports Server (NTRS)
Meredith, Roger D.; Neudeck, Philip G.; Ponchak, George E.; Beheim, Glenn M.; Scardelletti, Maximilian; Jordan, Jennifer L.; Chen, Liang-Yu; Spry, David J.; Krawowski, Michael J.; Hunter, Gary W.
2011-01-01
In an effort to develop harsh environment electronic and sensor technologies for aircraft engine safety and monitoring, we have used capacitive-based pressure sensors to shift the frequency of a SiC-electronics-based oscillator to produce a pressure-indicating signal that can be readily transmitted, e.g. wirelessly, to a receiver located in a more benign environment. Our efforts target 500 C, a temperature well above normal operating conditions of commercial circuits but within areas of interest in aerospace engines, deep mining applications and for future missions to the Venus atmosphere. This paper reports for the first time a ring oscillator circuit integrated with a capacitive pressure sensor, both operating at 500 C. This demonstration represents a significant step towards a wireless pressure sensor that can operate at 500 C and confirms the viability of 500 C electronic sensor systems.
NASA Astrophysics Data System (ADS)
Takahashi, Hidetoshi; Tomimatsu, Yutaka; Kobayashi, Takeshi; Isozaki, Akihiro; Itoh, Toshihiro; Maeda, Ryutaro; Matsumoto, Kiyoshi; Shimoyama, Isao
2014-02-01
This paper reports on a smart, intermittent driven particle sensor with an airflow trigger. A lead zirconate titanate cantilever functions as the trigger, which detects an airflow change without requiring a power supply to drive the sensing element. Because an airflow change indicates that the particle concentration has changed, the trigger switches the optical particle counter from sleep mode to active mode only when the particle concentration surrounding the sensor changes. The sensor power consumption in sleep mode is 100 times less than that in the active mode. Thus, this intermittent driven method significantly reduces the total power consumption of the particle sensor. In this paper, we fabricate a prototype of the particle sensor and demonstrate that the optical particle counter can be switched on by the fabricated trigger and thus that the particle concentration can be measured.
Applications of Ionic Liquids for the Development of Optical Chemical Sensors and Biosensors.
Muginova, Svetlana V; Myasnikova, Dina A; Kazarian, Sergei G; Shekhovtsova, Tatiana N
2017-01-01
This paper reviews the primary literature reporting the use of ionic liquids (ILs) in optical sensing technologies. The optical chemical sensors that have been developed with the assistance of ILs are classified according to the type of resultant material. Key aspects of applying ILs in such sensors are revealed and discussed. They include using ILs as solvents for the synthesis of sensor matrix materials; additives in polymer matrices; matrix materials; modifiers of the surfaces; and multifunctional sensor components. The operational principles, design, texture, and analytical characteristics of the offered sensors for determining CO 2 , O 2 , metal ions, CN - , and various organic compounds are critically discussed. The key advantages and disadvantages of using ILs in optical sensing technologies are defined. Finally, the applicability of the described materials for chemical analysis is evaluated, and possibilities for their further modernization are outlined.
Analyzing Responses of Chemical Sensor Arrays
NASA Technical Reports Server (NTRS)
Zhou, Hanying
2007-01-01
NASA is developing a third-generation electronic nose (ENose) capable of continuous monitoring of the International Space Station s cabin atmosphere for specific, harmful airborne contaminants. Previous generations of the ENose have been described in prior NASA Tech Briefs issues. Sensor selection is critical in both (prefabrication) sensor material selection and (post-fabrication) data analysis of the ENose, which detects several analytes that are difficult to detect, or that are at very low concentration ranges. Existing sensor selection approaches usually include limited statistical measures, where selectivity is more important but reliability and sensitivity are not of concern. When reliability and sensitivity can be major limiting factors in detecting target compounds reliably, the existing approach is not able to provide meaningful selection that will actually improve data analysis results. The approach and software reported here consider more statistical measures (factors) than existing approaches for a similar purpose. The result is a more balanced and robust sensor selection from a less than ideal sensor array. The software offers quick, flexible, optimal sensor selection and weighting for a variety of purposes without a time-consuming, iterative search by performing sensor calibrations to a known linear or nonlinear model, evaluating the individual sensor s statistics, scoring the individual sensor s overall performance, finding the best sensor array size to maximize class separation, finding optimal weights for the remaining sensor array, estimating limits of detection for the target compounds, evaluating fingerprint distance between group pairs, and finding the best event-detecting sensors.
Real-time sensor data validation
NASA Technical Reports Server (NTRS)
Bickmore, Timothy W.
1994-01-01
This report describes the status of an on-going effort to develop software capable of detecting sensor failures on rocket engines in real time. This software could be used in a rocket engine controller to prevent the erroneous shutdown of an engine due to sensor failures which would otherwise be interpreted as engine failures by the control software. The approach taken combines analytical redundancy with Bayesian belief networks to provide a solution which has well defined real-time characteristics and well-defined error rates. Analytical redundancy is a technique in which a sensor's value is predicted by using values from other sensors and known or empirically derived mathematical relations. A set of sensors and a set of relations among them form a network of cross-checks which can be used to periodically validate all of the sensors in the network. Bayesian belief networks provide a method of determining if each of the sensors in the network is valid, given the results of the cross-checks. This approach has been successfully demonstrated on the Technology Test Bed Engine at the NASA Marshall Space Flight Center. Current efforts are focused on extending the system to provide a validation capability for 100 sensors on the Space Shuttle Main Engine.
Chen, Wenjun; Gui, Xuchun; Liang, Binghao; Yang, Rongliang; Zheng, Yongjia; Zhao, Chengchun; Li, Xinming; Zhu, Hai; Tang, Zikang
2017-07-19
Nature-motivated pressure sensors have been greatly important components integrated into flexible electronics and applied in artificial intelligence. Here, we report a high sensitivity, ultrathin, and transparent pressure sensor based on wrinkled graphene prepared by a facile liquid-phase shrink method. Two pieces of wrinkled graphene are face to face assembled into a pressure sensor, in which a porous anodic aluminum oxide (AAO) membrane with the thickness of only 200 nm was used to insulate the two layers of graphene. The pressure sensor exhibits ultrahigh operating sensitivity (6.92 kPa -1 ), resulting from the insulation in its inactive state and conduction under compression. Formation of current pathways is attributed to the contact of graphene wrinkles through the pores of AAO membrane. In addition, the pressure sensor is also an on/off and energy saving device, due to the complete isolation between the two graphene layers when the sensor is not subjected to any pressure. We believe that our high-performance pressure sensor is an ideal candidate for integration in flexible electronics, but also paves the way for other 2D materials to be involved in the fabrication of pressure sensors.
Microwave Sensors for Breast Cancer Detection
2018-01-01
Breast cancer is the leading cause of death among females, early diagnostic methods with suitable treatments improve the 5-year survival rates significantly. Microwave breast imaging has been reported as the most potential to become the alternative or additional tool to the current gold standard X-ray mammography for detecting breast cancer. The microwave breast image quality is affected by the microwave sensor, sensor array, the number of sensors in the array and the size of the sensor. In fact, microwave sensor array and sensor play an important role in the microwave breast imaging system. Numerous microwave biosensors have been developed for biomedical applications, with particular focus on breast tumor detection. Compared to the conventional medical imaging and biosensor techniques, these microwave sensors not only enable better cancer detection and improve the image resolution, but also provide attractive features such as label-free detection. This paper aims to provide an overview of recent important achievements in microwave sensors for biomedical imaging applications, with particular focus on breast cancer detection. The electric properties of biological tissues at microwave spectrum, microwave imaging approaches, microwave biosensors, current challenges and future works are also discussed in the manuscript. PMID:29473867
Flexible Piezoresistive Sensors Embedded in 3D Printed Tires
Emon, Md Omar Faruk; Choi, Jae-Won
2017-01-01
In this article, we report the development of a flexible, 3D printable piezoresistive pressure sensor capable of measuring force and detecting the location of the force. The multilayer sensor comprises of an ionic liquid-based piezoresistive intermediate layer in between carbon nanotube (CNT)-based stretchable electrodes. A sensor containing an array of different sensing units was embedded on the inner liner surface of a 3D printed tire to provide with force information at different points of contact between the tire and road. Four scaled tires, as well as wheels, were 3D printed using a flexible and a rigid material, respectively, which were later assembled with a 3D-printed chassis. Only one tire was equipped with a sensor and the chassis was driven through a motorized linear stage at different speeds and load conditions to evaluate the sensor performance. The sensor was fabricated via molding and screen printing processes using a commercially available 3D-printable photopolymer as 3D printing is our target manufacturing technique to fabricate the entire tire assembly with the sensor. Results show that the proposed sensors, inserted in the 3D printed tire assembly, could detect forces, as well as their locations, properly. PMID:28327533
Flexible Piezoresistive Sensors Embedded in 3D Printed Tires.
Emon, Md Omar Faruk; Choi, Jae-Won
2017-03-22
In this article, we report the development of a flexible, 3D printable piezoresistive pressure sensor capable of measuring force and detecting the location of the force. The multilayer sensor comprises of an ionic liquid-based piezoresistive intermediate layer in between carbon nanotube (CNT)-based stretchable electrodes. A sensor containing an array of different sensing units was embedded on the inner liner surface of a 3D printed tire to provide with force information at different points of contact between the tire and road. Four scaled tires, as well as wheels, were 3D printed using a flexible and a rigid material, respectively, which were later assembled with a 3D-printed chassis. Only one tire was equipped with a sensor and the chassis was driven through a motorized linear stage at different speeds and load conditions to evaluate the sensor performance. The sensor was fabricated via molding and screen printing processes using a commercially available 3D-printable photopolymer as 3D printing is our target manufacturing technique to fabricate the entire tire assembly with the sensor. Results show that the proposed sensors, inserted in the 3D printed tire assembly, could detect forces, as well as their locations, properly.
Microwave Sensors for Breast Cancer Detection.
Wang, Lulu
2018-02-23
Breast cancer is the leading cause of death among females, early diagnostic methods with suitable treatments improve the 5-year survival rates significantly. Microwave breast imaging has been reported as the most potential to become the alternative or additional tool to the current gold standard X-ray mammography for detecting breast cancer. The microwave breast image quality is affected by the microwave sensor, sensor array, the number of sensors in the array and the size of the sensor. In fact, microwave sensor array and sensor play an important role in the microwave breast imaging system. Numerous microwave biosensors have been developed for biomedical applications, with particular focus on breast tumor detection. Compared to the conventional medical imaging and biosensor techniques, these microwave sensors not only enable better cancer detection and improve the image resolution, but also provide attractive features such as label-free detection. This paper aims to provide an overview of recent important achievements in microwave sensors for biomedical imaging applications, with particular focus on breast cancer detection. The electric properties of biological tissues at microwave spectrum, microwave imaging approaches, microwave biosensors, current challenges and future works are also discussed in the manuscript.
Watson, Jean-Paul; Murray, Regan; Hart, William E.
2009-11-13
We report that the sensor placement problem in contamination warning system design for municipal water distribution networks involves maximizing the protection level afforded by limited numbers of sensors, typically quantified as the expected impact of a contamination event; the issue of how to mitigate against high-consequence events is either handled implicitly or ignored entirely. Consequently, expected-case sensor placements run the risk of failing to protect against high-consequence 9/11-style attacks. In contrast, robust sensor placements address this concern by focusing strictly on high-consequence events and placing sensors to minimize the impact of these events. We introduce several robust variations of themore » sensor placement problem, distinguished by how they quantify the potential damage due to high-consequence events. We explore the nature of robust versus expected-case sensor placements on three real-world large-scale distribution networks. We find that robust sensor placements can yield large reductions in the number and magnitude of high-consequence events, with only modest increases in expected impact. Finally, the ability to trade-off between robust and expected-case impacts is a key unexplored dimension in contamination warning system design.« less
Wagner, Richard J.; Boulger, Robert W.; Oblinger, Carolyn J.; Smith, Brett A.
2006-01-01
The U.S. Geological Survey uses continuous water-quality monitors to assess the quality of the Nation's surface water. A common monitoring-system configuration for water-quality data collection is the four-parameter monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data. Such systems also can be configured to measure other properties, such as turbidity or fluorescence. Data from sensors can be used in conjunction with chemical analyses of samples to estimate chemical loads. The sensors that are used to measure water-quality field parameters require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. This report provides guidelines for site- and monitor-selection considerations; sensor inspection and calibration methods; field procedures; data evaluation, correction, and computation; and record-review and data-reporting processes, which supersede the guidelines presented previously in U.S. Geological Survey Water-Resources Investigations Report WRIR 00-4252. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.
Airborne Electro-Optical Sensor Simulation System. Final Report.
ERIC Educational Resources Information Center
Hayworth, Don
The total system capability, including all the special purpose and general purpose hardware comprising the Airborne Electro-Optical Sensor Simulation (AEOSS) System, is described. The functional relationship between hardware portions is described together with interface to the software portion of the computer image generation. Supporting rationale…
MEASUREMENT AND ANALYSIS OF VAPOR SENSORS USED AT UNDERGROUND STORAGE TANK SITES
This report is a continuation of an investigation to quantify the operating characteristics of vapor sensor technologies used at underground storage tank (UST) sites. n the previous study (EPA/600/R-92/219) the sensitivity, selectivity, and response time to simulated UST environm...
RADIATION-RESISTANT FIBER OPTIC STRAIN SENSORS FOR SNS TARGET INSTRUMENTATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blokland, Willem; Bryan, Jeff; Riemer, Bernie
2016-01-01
Measurement of stresses and strains in the mercury tar-get vessel of the Spallation Neutron Source (SNS) is important to understand the structural dynamics of the target. This work reports the development of radiation-resistant fiber optic strain sensors for the SNS target in-strumentation.
50 CFR 218.125 - Requirements for monitoring and reporting.
Code of Federal Regulations, 2011 CFR
2011-10-01
... observers maintained visual contact with marine mammal(s); (H) Wave height (ft); (I) Visibility; (J) Sonar..., low, and average during exercise); and (I) Narrative description of sensors and platforms utilized for...) Calves observed (y/n); (E) Initial detection sensor; (F) Length of time observers maintained visual...
DOT National Transportation Integrated Search
1975-08-01
This report outlines the engineering requirements for an Airborne Laser Remote Sensor for Oil Detection and Classification System. Detailed engineering requirements are given for the major units of the system. Technical considerations pertinent to a ...
Development of a Multi-Sensor Cancer Detection Probe Final Report CRADA No. TC-2026-01
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marion, J.; Hular, R.
This collaboration continued work started under a previous CRADA (TSB-2023-00) to take a detailed concept specification for a multi-sensor needle/probe suitable for breast cancer analysis and produce a prototype system suitable for human FDA trials.
Space debris measurement program at Phillips Laboratory
NASA Technical Reports Server (NTRS)
Dao, Phan D.; Mcnutt, Ross T.
1992-01-01
Ground-based optical sensing was identified as a technique for measuring space debris complementary to radar in the critical debris size range of 1 to 10 cm. The Phillips Laboratory is building a staring optical sensor for space debris measurement and considering search and track optical measurement at additional sites. The staring sensor is implemented in collaboration with Wright Laboratory using the 2.5 m telescope at Wright Patterson AFB, Dayton, Ohio. The search and track sensor is designed to detect and track orbital debris in tasked orbits. A progress report and a discussion of sensor performance and search and track strategies will be given.
NASA Astrophysics Data System (ADS)
Arefin, Md Shamsul; Porter, Timothy L.
2012-03-01
This work reports on the behavior of piezoresistive microcantilever sensors under optimizing conditions of ac electroosmotic enhancement. Piezoresistive microcantilevers are used as sensor elements for detection of concentrated bio-particles. Without preconcentrating the samples, using ac electroosmosis, these bio-particles have been manipulated onto the piezoresistive microcantilever. A piezoresistive microcantilever senses the dimensional changes upon particle exposure as a resistance change. This paper represents the integration of ac electroosmosis with a piezoresistive micro-cantilever sensor for the detection of bio-particles. A working prototype is presented here, and the experiments are conducted on Herpes Simplex type-1 virus (HSV-1) and Escherichia Coli (E. coli) bacteria.