EAST ELEVATION OF HIGH BAY ADDITION OF FUEL STORAGE BUILDING ...
EAST ELEVATION OF HIGH BAY ADDITION OF FUEL STORAGE BUILDING (CPP-603). INL DRAWING NUMBER 200-0603-00-706-051286. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
EQUIPMENT LAYOUT OF MAIN PROCESSING BUILDING (CPP601) LCELL PLAN AND ...
EQUIPMENT LAYOUT OF MAIN PROCESSING BUILDING (CPP-601) L-CELL PLAN AND SECTION SHOWS COMPLEXITY OF CELLS. INL DRAWING NUMBER 200-0601-00-098-105687. ALTERNATE ID NUMBER 4289-20-301. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION VIEW OF MAIN PROCESSING BUILDING (CPP601) LOOKING NORTHWEST. INL ...
CONSTRUCTION VIEW OF MAIN PROCESSING BUILDING (CPP-601) LOOKING NORTHWEST. INL PHOTO NUMBER NRTS-51-1390. Unknown Photographer, 1/31/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP627). INL PHOTO ...
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP-627). INL PHOTO NUMBER NRTS-54-12124. Unknown Photographer, 9/21/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
DETAILS OF REMOTE ANALYTICAL FACILITY (CPP627). INL DRAWING NUMBER 200062700098105071. ...
DETAILS OF REMOTE ANALYTICAL FACILITY (CPP-627). INL DRAWING NUMBER 200-0627-00-098-105071. ALTERNATE ID NUMBER 4272-14-108. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION VIEW OF MAIN PROCESSING BUILDING (CPP601) LOOKING EAST. INL ...
CONSTRUCTION VIEW OF MAIN PROCESSING BUILDING (CPP-601) LOOKING EAST. INL PHOTO NUMBER NRTS-51-1547. Unknown Photographer, 2/28/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO SHOWING WEST STORAGE BASIN AT FUEL STORAGE ...
CONSTRUCTION PROGRESS PHOTO SHOWING WEST STORAGE BASIN AT FUEL STORAGE BUILDING (CPP-603). INL PHOTO NUMBER NRTS-51-689. Unknown Photographer, 1950 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO SHOWING EXCAVATION PIT FOR MAIN PROCESSING BUILDING ...
CONSTRUCTION PROGRESS PHOTO SHOWING EXCAVATION PIT FOR MAIN PROCESSING BUILDING (CPP-601) LOOKING SOUTH. INL PHOTO NUMBER NRTS-50-693. Unknown Photographer, 1950 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
MISCELLANEOUS ARCHITECTURAL DETAILS OF REMOTE ANALYTICAL FACILITY (CPP627). INL DRAWING ...
MISCELLANEOUS ARCHITECTURAL DETAILS OF REMOTE ANALYTICAL FACILITY (CPP-627). INL DRAWING NUMBER 200-0627-00-098-105631. ALTERNATE ID NUMBER 4272-814-134. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION VIEW FUEL STORAGE BUILDING (CPP603) LOOKING EAST SHOWING ASBESTOS ...
CONSTRUCTION VIEW FUEL STORAGE BUILDING (CPP-603) LOOKING EAST SHOWING ASBESTOS SIDING. INL PHOTO NUMBER NRTS-51-1543. Unknown Photographer, 2/28/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO SHOWING MAIN PROCESSING BUILDING (CPP601) LOOKING NORTH. ...
CONSTRUCTION PROGRESS PHOTO SHOWING MAIN PROCESSING BUILDING (CPP-601) LOOKING NORTH. INL PHOTO NUMBER NRTS-51-1387. Unknown Photographer, 1/31/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SOUTH ELEVATION OF HOT PILOT PLANT (CPP640) LOOKING NORTH. INL ...
SOUTH ELEVATION OF HOT PILOT PLANT (CPP-640) LOOKING NORTH. INL PHOTO NUMBER HD-22-3-1. Mike Crane, Photographer, 11/1998 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO SHOWING FUEL STORAGE BUILDING (CPP603) LOOKING NORTHWEST. ...
CONSTRUCTION PROGRESS PHOTO SHOWING FUEL STORAGE BUILDING (CPP-603) LOOKING NORTHWEST. INL PHOTO NUMBER NRTS-50-895. Unknown Photographer, 10/30/1950 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
BUILDING PLANS OF FUEL STORAGE BUILDING (CPP603). INL DRAWING NUMBER ...
BUILDING PLANS OF FUEL STORAGE BUILDING (CPP-603). INL DRAWING NUMBER 200-0603-61-299-103029. ALTERNATE ID NUMBER 542-31-B-21. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP627). INL PHOTO ...
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP-627). INL PHOTO NUMBER NRTS-54-12573. R.G. Larsen, Photographer, 10/20/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING INITIAL ...
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING INITIAL EXCAVATION. INL PHOTO NUMBER NRTS-54-10703. Unknown Photographer, 5/21/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SOUTH ELEVATION OF MAIN PROCESSING BUILDING (CPP601) LOOKING NORTH. INL ...
SOUTH ELEVATION OF MAIN PROCESSING BUILDING (CPP-601) LOOKING NORTH. INL PHOTO NUMBER HD-22-5-3. Mike Crane, Photographer, 11/1998 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
MISCELLANEOUS ARCHITECTURAL DETAILS AND SECTIONS OF REMOTE ANALYTICAL FACILITY (CPP627). ...
MISCELLANEOUS ARCHITECTURAL DETAILS AND SECTIONS OF REMOTE ANALYTICAL FACILITY (CPP-627). INL DRAWING NUMBER 200-0627-00-098-105632. ALTERNATE ID NUMBER 4272-814-135. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO SHOWING EXCAVATION PIT FOR MAIN PROCESSING BUILDING ...
CONSTRUCTION PROGRESS PHOTO SHOWING EXCAVATION PIT FOR MAIN PROCESSING BUILDING (CPP-601) LOOKING NORTHWEST. INL PHOTO NUMBER NRTS-50-885. Unknown Photographer, 10/30/1950 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
MISCELLANEOUS SECTIONS AND DETAILS OF FUEL STORAGE BUILDING (CPP603). INL ...
MISCELLANEOUS SECTIONS AND DETAILS OF FUEL STORAGE BUILDING (CPP-603). INL DRAWING NUMBER 200-0603-61-299-103032. ALTERNATE ID NUMBER 542-31-B-24. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
WEST ELEVATION OF FUEL STORAGE BUILDING (CPP603). PHOTO TAKEN LOOKING ...
WEST ELEVATION OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTHEAST. INL PHOTO NUMBER HD-54-20-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SOUTH ELEVATION AND DETAILS OF MAIN PROCESSING BUILDING (CPP601). INL ...
SOUTH ELEVATION AND DETAILS OF MAIN PROCESSING BUILDING (CPP-601). INL DRAWING NUMBER 200-0601-00-291-103082. ALTERNATE ID NUMBER 542-12-B-76. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
ARCHITECTURAL WALL SECTIONS OF HOT PILOT PLANT (CPP640). INL DRAWING ...
ARCHITECTURAL WALL SECTIONS OF HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111682. ALTERNATE ID NUMBER 8952-CPP-640-A-5. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTH AND SOUTH SECTIONS OF REMOTE ANALYTICAL FACILITY (CPP627). INL ...
NORTH AND SOUTH SECTIONS OF REMOTE ANALYTICAL FACILITY (CPP-627). INL DRAWING NUMBER 200-0627-00-098-105068. ALTERNATE ID NUMBER 4272-14-105. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
AERIAL VIEW OF MAIN PROCESSING BUILDING SHOWING CONSTRUCTION PROGRESS AND ...
AERIAL VIEW OF MAIN PROCESSING BUILDING SHOWING CONSTRUCTION PROGRESS AND EXCAVATION FOR LABORATORY ON LEFT. INL PHOTO NUMBER NRTS-51-1759. Unknown Photographer, 3/28/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
EAST AND WEST ELEVATIONS OF REMOTE ANALYTICAL FACILITY (CPP627). INL ...
EAST AND WEST ELEVATIONS OF REMOTE ANALYTICAL FACILITY (CPP-627). INL DRAWING NUMBER 200-0627-00-098-105067. ALTERNATE ID NUMBER 4272-14-104. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
EAST AND WEST ELEVATIONS OF MAIN PROCESSING BUILDING (CPP601). INL ...
EAST AND WEST ELEVATIONS OF MAIN PROCESSING BUILDING (CPP-601). INL DRAWING NUMBER 200-0601-00-291-103081. ALTERNATE ID NUMBER 542-11-B-75. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
WEST ELEVATIONS AND SECTIONS OF FUEL STORAGE BUILDING (CPP603). INL ...
WEST ELEVATIONS AND SECTIONS OF FUEL STORAGE BUILDING (CPP-603). INL DRAWING NUMBER 200-063-61-299-103031. ALTERNATE ID NUMBER 542-31-B-23. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF THE REMOTE ANALYTICAL FACILITY OF SHIELDED GLOVE ...
INTERIOR PHOTO OF THE REMOTE ANALYTICAL FACILITY OF SHIELDED GLOVE BOXES IN OPERATING CORRIDOR (CPP-627). INL PHOTO NUMBER NRTS-55-1524. Unknown Photographer, 1955 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO SHOWING EMPLACEMENT STEEL BEAMS FUEL STORAGE BUILDING ...
CONSTRUCTION PROGRESS PHOTO SHOWING EMPLACEMENT STEEL BEAMS FUEL STORAGE BUILDING (CPP-603) LOOKING EAST. INL PHOTO NUMBER NRTS-51-1371. Unknown Photographer, 1/31/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
MISCELLANEOUS ARCHITECTURAL DETAILS OF HOT PILOT PLANT (CPP640). INL DRAWING ...
MISCELLANEOUS ARCHITECTURAL DETAILS OF HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-640-00-279-111684. ALTERNATE ID NUMBER 8952-CPP-640-A-7. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SIDING AND ROOF DETAILS OF FUEL STORAGE BUILDING (CPP603). INL ...
SIDING AND ROOF DETAILS OF FUEL STORAGE BUILDING (CPP-603). INL DRAWING NUMBER 200-0603-61-299-103033. ALTERNATE ID NUMBER 542-31-B-25. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR VIEW OF FUEL STORAGE BUILDING (CPP603) SHOWING CRANE ASSEMBLY ...
INTERIOR VIEW OF FUEL STORAGE BUILDING (CPP-603) SHOWING CRANE ASSEMBLY FOR TRANSFER PIT. INL PHOTO NUMBER NRTS-51-2404. Unknown Photographer, 5/31/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
PLAN VIEW OF FUEL STORAGE BUILDING (CPP603) SHOWING STORAGE BASINS. ...
PLAN VIEW OF FUEL STORAGE BUILDING (CPP-603) SHOWING STORAGE BASINS. INL DRAWING NUMBER 200-0603-00-706-051285. ALTERNATE ID NUMBER CPP-D-1285. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
WEST ELEVATION OF FUEL STORAGE BUILDING (CPP603). PHOTO TAKEN LOOKING ...
WEST ELEVATION OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTHEAST. INL PHOTO NUMBER HD-54-20-3. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
BUILDING DETAILS AND SECTIONS OF MAIN PROCESSING BUILDING (CPP601). INL ...
BUILDING DETAILS AND SECTIONS OF MAIN PROCESSING BUILDING (CPP-601). INL DRAWING NUMBER 200-0601-00-291-103080. ALTERNATE ID NUMBER 542-11-B-74. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
STRUCTURAL DETAILS AND SECTIONS OF MAIN PROCESSING BUILDING (CPP601). INL ...
STRUCTURAL DETAILS AND SECTIONS OF MAIN PROCESSING BUILDING (CPP-601). INL DRAWING NUMBER 200-0601-00-291-103079. ALTERNATE ID NUMBER 542-11-B-73. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING PLACEMENT ...
CONSTRUCTION PROGRESS PHOTO OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING PLACEMENT OF PIERS. INL PHOTO NUMBER NRTS-54-11716. Unknown Photographer, 8/20/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SOUTH, EAST, NORTH ELEVATIONS AND SECTIONS OF FUEL STORAGE BUILDING ...
SOUTH, EAST, NORTH ELEVATIONS AND SECTIONS OF FUEL STORAGE BUILDING (CPP-603). INL DRAWING NUMBER 200-0603-61-299-103030. ALTERNATE ID NUMBER 542-31-B-22. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR OF SECOND FLOOR CONTROL ROOM OF FUEL STORAGE BUILDING ...
INTERIOR OF SECOND FLOOR CONTROL ROOM OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTHWEST. INL PHOTO NUMBER HD-54-19-2. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTHERN PORTION OF WEST ELEVATION OF FUEL STORAGE BUILDING (CPP603). ...
NORTHERN PORTION OF WEST ELEVATION OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTHEAST. INL PHOTO NUMBER HD-54-20-4. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
EAST WEST NORTH ELEVATIONS OF MULTICURIE CELL ARCHITECTURAL DETAILS REMOTE ...
EAST WEST NORTH ELEVATIONS OF MULTICURIE CELL ARCHITECTURAL DETAILS REMOTE ANALYTICAL FACILITY (CPP-627). INL DRAWING NUMBER 200-00627-00-706-050245. ALTERNATE ID NUMBER AED-D-245. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
ARCHITECTURAL FLOOR PLAN OF OPERATING AREA HOT PILOT PLANT (CPP640). ...
ARCHITECTURAL FLOOR PLAN OF OPERATING AREA HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111678. ALTERNATE ID NUMBER 8952-CPP-640-A-1. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
OBLIQUE PHOTO OF NORTHWEST CORNER OF FUEL STORAGE BUILDING (CPP603). ...
OBLIQUE PHOTO OF NORTHWEST CORNER OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTHEAST. INL PHOTO NUMBER HD-54-14-4. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTHERN PORTION OF WEST ELEVATION OF FUEL STORAGE BUILDING (CPP603). ...
NORTHERN PORTION OF WEST ELEVATION OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTHEAST. INL PHOTO NUMBER HD-54-20-2. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
VIEW OF FECF HOT CELL OF FUEL STORAGE BUILDING (CPP603). ...
VIEW OF FECF HOT CELL OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORHTWEST. INL PHOTO NUMBER HD-54-18-3. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO REMOTE ANALYTICAL FACILITY (CPP627) SHOWING EMPLACEMENT OF ...
CONSTRUCTION PROGRESS PHOTO REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING EMPLACEMENT OF ROOF SLABS. INL PHOTO NUMBER NRTS-54-13463. R.G. Larsen, Photographer, 12/20/1954 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
VIEW OF TRANSFER BASIN CORRIDOR OF FUEL STORAGE BUILDING (CPP603). ...
VIEW OF TRANSFER BASIN CORRIDOR OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTH. INL PHOTO NUMBER HD-54-17-2. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
PLAN SECTIONS AND DETAILS OF CELL HATCHES MAIN PROCESSING BUILDING ...
PLAN SECTIONS AND DETAILS OF CELL HATCHES MAIN PROCESSING BUILDING (CPP-601). INL DRAWING NUMBER 200-0601-00-291-103256. ALTERNATE ID NUMBER 542-11-F-302. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
OBLIQUE PHOTO OF NORTH ELEVATION OF FUEL STORAGE BUILDING (CPP603). ...
OBLIQUE PHOTO OF NORTH ELEVATION OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTH. INL PHOTO NUMBER HD-54-14-3. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
ARCHITECTURAL DOOR DETAILS AND SCHEDULE OF HOT PILOT PLANT (CPP640). ...
ARCHITECTURAL DOOR DETAILS AND SCHEDULE OF HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-640-00-279-111683. ALTERNATE ID NUMBER 8952-CPP-640-A-6. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
ARCHITECTURAL SECTIONS A, B, C, D, OF HOT PILOT PLANT ...
ARCHITECTURAL SECTIONS A, B, C, D, OF HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111681. ALTERNATE ID NUMBER 8952-CPP-640-A-5. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
WEST ELEVATION OF REMOTE ANALYTICAL FACILITY (CPP627) AND HOT PILOT ...
WEST ELEVATION OF REMOTE ANALYTICAL FACILITY (CPP-627) AND HOT PILOT PLANT (CPP-640) LOOKING NORTHEAST. INL PHOTO NUMBER HD-22-2-1. Mike Crane, Photographer, 11/1998 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE ...
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTH. INL PHOTO NUMBER HD-54-17-4. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
ARCHITECTURAL FLOOR PLAN OF PROCESS AND ACCESS AREAS HOT PILOT ...
ARCHITECTURAL FLOOR PLAN OF PROCESS AND ACCESS AREAS HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111679. ALTERNATE ID NUMBER 8952-CPP-640-A-2. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
FACILITY LAYOUT OF FUEL STORAGE BUILDING (CPP603) SHOWING STORAGE BASINS, ...
FACILITY LAYOUT OF FUEL STORAGE BUILDING (CPP-603) SHOWING STORAGE BASINS, FUEL ELEMENT CUTTING FACILITY, AND DRY GRAPHITE STORAGE FACILITY. INL DRAWING NUMBER 200-0603-00-030-056329. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
0BLIQUE PHOTO OF EAST ELEVATION OF FUEL STORAGE BUILDING (CPP603). ...
0BLIQUE PHOTO OF EAST ELEVATION OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING WEST. INL PHOTO NUMBER HD-54-15-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP640) OVERALL VIEW ...
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP-640) OVERALL VIEW LOOKING SOUTHEAST; CONSTRUCTION 34 PERCENT COMPLETE. INL PHOTO NUMBER NRTS-60-3034. Holmes, Photographer, 6/23/1960 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTH ELEVATION OF HOT PILOT PLANT (CPP640) LOOKING SOUTH AFTER ...
NORTH ELEVATION OF HOT PILOT PLANT (CPP-640) LOOKING SOUTH AFTER REMOTE ANALYTICAL FACILITY (CPP-627) WAS REMOVED. PHOTO NUMBER HD-54-33-2. Mike Crane, Photographer, 7/2006 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE ...
VIEW OF CRANE LOADING AND UNLOADING AREA OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTH. INL PHOTO NUMBER HD-54-17-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION VIEW OF MAIN PROCESSING BUILDING (CPP601) ON THE RIGHT ...
CONSTRUCTION VIEW OF MAIN PROCESSING BUILDING (CPP-601) ON THE RIGHT AND LABORATORY (CPP-602) ON THE LEFT. INL PHOTO NUMBER NRTS-51-3373. Unknown Photographer, 9/28/1951 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
VIEW OF SOUTH STORAGE BASIN NUMBER 1 OF FUEL STORAGE ...
VIEW OF SOUTH STORAGE BASIN NUMBER 1 OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTHEAST. INL PHOTO NUMBER HD-54-18-4. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
VIEW OF MIDDLE STORAGE BASIN NUMBER 2 OF FUEL STORAGE ...
VIEW OF MIDDLE STORAGE BASIN NUMBER 2 OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTHEAST. INL PHOTO NUMBER HD-54-17-3. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
ARCHITECTURAL ROOF PLAN AND WESTSOUTHEAST ELEVATIONS OF HOT PILOT PLANT ...
ARCHITECTURAL ROOF PLAN AND WEST-SOUTHEAST ELEVATIONS OF HOT PILOT PLANT (CPP-640). INL DRAWING NUMBER 200-0640-00-279-111680. ALTERNATE ID NUMBER 8952-CPP-640-A-3. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SOUTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL ...
SOUTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTH. INL PHOTO NUMBER HD-54-15-2. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL ...
NORTH ELEVATION OF IRRADIATED FUEL STORAGE FACILITY LOCATED IN FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING SOUTH. INL PHOTO NUMBER HD-54-16-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP601) ...
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP-601) LOOKING SOUTHWEST. PHOTO TAKEN FROM NORTHEAST CORNER. INL PHOTO NUMBER HD-50-4-2. Mike Crane, Photographer, 6/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING REMOTE ...
FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL LABORATORY, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. INL DRAWING NUMBER 200-0627-00-008-105065. ALTERNATE ID NUMBER 4272-14-102. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
PLOT PLAN OF FUEL STORAGE BUILDING (CPP603) SHOWING STORAGE BASINS ...
PLOT PLAN OF FUEL STORAGE BUILDING (CPP-603) SHOWING STORAGE BASINS AND PROPOSED LOCATION OF FUEL ELEMENT CUTTING FACILITY. INL DRAWING NUMBER 200-0603-00-706-051287. ALTERNATE ID NUMBER CPP-C-1287. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP601) ...
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP-601) LOOKING NORTH. PHOTO TAKEN FROM SOUTHWEST CORNER. INL PHOTO NUMBER HD-50-1-3. Mike Crane, Photographer, 6/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP640) LOOKING NORTHEAST ...
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP-640) LOOKING NORTHEAST SHOWING OVERALL BLOCK EXTERIOR WALLS; CONSTRUCTION 65 PERCENT COMPLETE. INL PHOTO NUMBER NRTS-60-4976. Holmes, Photographer, 9/26/1960 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP640) LOOKING EAST ...
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP-640) LOOKING EAST SHOWING EXCAVATION AND FORMING; CONSTRUCTION 6 PERCENT COMPLETE. INL PHOTO NUMBER NRTS-59-4935. J. Anderson, Photographer, 9/21/1959 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF MAIN PROCESSING BUILDING (CPP601) PROCESS MAKEUP AREA ...
INTERIOR PHOTO OF MAIN PROCESSING BUILDING (CPP-601) PROCESS MAKEUP AREA LOOKING SOUTH. PHOTO TAKEN FROM CENTER OF WEST WALL. INL PHOTO NUMBER HD-50-1-4. Mike Crane, Photographer, 6/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTH AND WEST ELEVATIONS OF REMOTE ANALYTICAL FACILITY (CPP627) LOOKING ...
NORTH AND WEST ELEVATIONS OF REMOTE ANALYTICAL FACILITY (CPP-627) LOOKING SOUTHEAST. HEADEND PLANT (CPP-640) APPEARS IN THE BACKGROUND. INL PHOTO NUMBER HD-22-1-4. Mike Crane, Photographer, 11/1998 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR DEPICTING DETAIL ...
INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR DEPICTING DETAIL OF SHIELDED CAVE (CPP-640) LOOKING SOUTHWEST. PHOTO TAKEN FROM NORTH. INL PHOTO NUMBER HD-54-40-2. Mike Crane, Photographer, 7/2006 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
PLAN SECTIONS AND ELEVATIONS OF VESSEL SAMPLING STATIONS "P", "Q", ...
PLAN SECTIONS AND ELEVATIONS OF VESSEL SAMPLING STATIONS "P", "Q", "S" CELLS MAIN PROCESSING BUILDING (CPP-601). INL DRAWING NUMBER 200-0601-00-291-053694. ALTERNATE ID NUMBER CPP-E-1394. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
EAST ELEVATION OF MAIN PROCESSING BUILDING (CPP601) LOOKING NORTHWEST. MAINTENANCE ...
EAST ELEVATION OF MAIN PROCESSING BUILDING (CPP-601) LOOKING NORTHWEST. MAINTENANCE SHOP AND OFFICE BUILDING (CPP-630) ON RIGHT IN PHOTO. INL PHOTO NUMBER HD-22-3-2. Mike Crane, Photographer, 11/1998 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR WITH SOUTH ...
INTERIOR PHOTO OF HOT PILOT PLANT SECOND FLOOR WITH SOUTH SECTION OF SHIELDED CAVE IN FOREGROUND (CPP-640) LOOKING NORTHWEST. INL PHOTO NUMBER HD-54-40-1. Mike Crane, Photographer, 7/2006 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP601) ...
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP-601) LOOKING NORTHWEST. PHOTO TAKEN FROM MIDDLE OF CORRIDOR. INL PHOTO NUMBER HD-50-2-3. Mike Crane, Photographer, 6/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP601) ...
INTERIOR PHOTO OF MAIN PROCESSING BUILDING PROCESS MAKEUP AREA (CPP-601) LOOKING SOUTH. PHOTO TAKEN FROM MIDDLE OF CORRIDOR. INL PHOTO NUMBER HD-50-3-2. Mike Crane, Photographer, 6/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
EAST/WEST TRUCK BAY AREA OF TRANSFER BASIN CORRIDOR OF FUEL ...
EAST/WEST TRUCK BAY AREA OF TRANSFER BASIN CORRIDOR OF FUEL STORAGE BUILDING (CPP-603). PHOTO TAKEN LOOKING NORTHWEST. INL PHOTO NUMBER HD-54-19-1. Mike Crane, Photographer, 8/2005 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
AERIAL SHOWING COMPLETED REMOTE ANALYTICAL FACILITY (CPP627) ADJOINING FUEL PROCESSING ...
AERIAL SHOWING COMPLETED REMOTE ANALYTICAL FACILITY (CPP-627) ADJOINING FUEL PROCESSING BUILDING AND EXCAVATION FOR HOT PILOT PLANT TO RIGHT (CPP-640). INL PHOTO NUMBER NRTS-60-1221. J. Anderson, Photographer, 3/22/1960 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601) BASEMENT SHOWING PROCESS ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601) BASEMENT SHOWING PROCESS CORRIDOR AND EIGHTEEN CELLS. TO LEFT IS LABORATORY BUILDING (CPP-602). INL DRAWING NUMBER 200-0601-00-706-051981. ALTERNATE ID NUMBER CPP-E-1981. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP640) LOOKING NORTHEAST ...
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP-640) LOOKING NORTHEAST SHOWING DECK FORMING FOR SOUTH SECTION OF OPERATING CORRIDOR; CONSTRUCTION 44 PERCENT COMPLETE. INL PHOTO NUMBER NRTS-60-3624. Holmes, Photographer, 7/25/1960 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SECOND FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP627) WARM LABORATORY ...
SECOND FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP-627) WARM LABORATORY ROOM, DECONTAMINATION ROOM, HOT CHEMISTRY LABORATORY, AND MULTICURIE CELL ROOM. INL DRAWING NUMBER 200-0627-00-098-105066. ALTERNATE ID NUMBER 4272-14-103. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP640) LOOKING NORTHWEST, ...
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CPP-640) LOOKING NORTHWEST, SHOWING FORMING FOR NORTH WALLS OF CELLS 1, 4 AND 5; CONSTRUCTION 21 PERCENT COMPLETE. INL PHOTO NUMBER NRTS-60-1874. Holmes, Photographer, 4/21/1960 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SOUTH SECTION OF WEST ELEVATION OF MAIN PROCESSING BUILDING (CPP601) ...
SOUTH SECTION OF WEST ELEVATION OF MAIN PROCESSING BUILDING (CPP-601) LOOKING EAST. HEADEND PLANT BUILDING (CPP-640) APPEARS ON LEFT IN PHOTO. INL PHOTO NUMBER HD-22-3-3. Mike Crane, Photographer, 11/1998 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
OBLIQUE PHOTO OF NORTH AND WEST ELEVATIONS OF REMOTE ANALYTICAL ...
OBLIQUE PHOTO OF NORTH AND WEST ELEVATIONS OF REMOTE ANALYTICAL FACILITY (CPP-627) LOOKING SOUTHEAST. LABORATORY AND OFFICE BUILDING (CPP-602) APPEAR ON LEFT IN PHOTO. INL PHOTO NUMBER HD-22-2-2. Mike Crane, Photographer, 11/1998 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
INTERIOR VIEW OF FUEL STORAGE BUILDING (CPP603) LOOKING SOUTHWEST SHOWING ...
INTERIOR VIEW OF FUEL STORAGE BUILDING (CPP-603) LOOKING SOUTHWEST SHOWING STORAGE BASIN IN FOREGROUND, TRANSFER CRANE AND UNLOADER TO LEFT OF NORTH SIDE OF HOT CELL. INL PHOTO NUMBER NRTS-58-157. J. Anderson, Photographer, 1/15/1958 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
NORTH SECTION OF WEST ELEVATION OF MAIN PROCESSING BUILDING (CPP601) ...
NORTH SECTION OF WEST ELEVATION OF MAIN PROCESSING BUILDING (CPP-601) LOOKING EAST. HOT PILOT PLANT BUILDING (CPP-640) APPEARS IN RIGHT OF PHOTO. THE REMOTE ANALYTICAL FACILITY (CPP-627) WAS LOCATED ON CONCRETE PAD IN FOREGROUND. INL PHOTO NUMBER HD-54-33-3. Mike Crane, Photographer, 7/2006 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CP640) LOOKING NORTHWEST ...
CONSTRUCTION PROGRESS PHOTO OF HOT PILOT PLANT (CP-640) LOOKING NORTHWEST SHOWING FORMING AND PLACEMENT OF REINFORCING STEEL FOR SOUTH WALLS OF CELLS 1, 3, 4 AND 5 AND WEST WALL FOR CELLS 1 AND 2; CONSTRUCTION 13 PERCENT COMPLETE. INL PHOTO NUMBER NRTS 59-6436. J. Anderson, Photographer, 12/18/1959 - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), SECOND FLOOR SHOWING ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), SECOND FLOOR SHOWING PROCESS MAKEUP AREA AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING COLD LAB, DECONTAMINATION ROOM, MULTICURIE CELL ROOM, AND OFFICES. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051980. ALTERNATE ID NUMBER CPP-E-1980. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), FIRST FLOOR SHOWING ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), FIRST FLOOR SHOWING SAMPLE CORRIDORS AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL FACILITIES LAB, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051979. ALTERNATE ID NUMBER CPP-E-1979. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
19. CONSTRUCTION PROGRESS PHOTO SHOWING (TYPICALLY COMPLEX) WASTE HOLDING CELL ...
19. CONSTRUCTION PROGRESS PHOTO SHOWING (TYPICALLY COMPLEX) WASTE HOLDING CELL PIPING. INEEL PHOTO NUMBER NRTS-59-3212. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
MTR AND ETR COMPLEXES. CAMERA FACING EASTERLY TOWARD CHEMICAL PROCESSING ...
MTR AND ETR COMPLEXES. CAMERA FACING EASTERLY TOWARD CHEMICAL PROCESSING PLANT. MTR AND ITS ATTACHMENTS IN FOREGROUND. ETR BEYOND TO RIGHT. INL NEGATIVE NO. 56-4100. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
39. CALCINER CELL PLANS. TOGETHER WITH HAER ID33C37 ILLUSTRATES COMPLEXITY ...
39. CALCINER CELL PLANS. TOGETHER WITH HAER ID-33-C-37 ILLUSTRATES COMPLEXITY OF PIPING. INEEL DRAWING NUMBER 200-0633-00-287-106445. FLUOR NUMBER 5775-CPP-633-P-50 - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
40. CALCINER CELL SECTIONS. TOGETHER WITH HAER ID33C37 ILLUSTRATES COMPLEXITY ...
40. CALCINER CELL SECTIONS. TOGETHER WITH HAER ID-33-C-37 ILLUSTRATES COMPLEXITY OF PIPING. INEEL DRAWING NUMBER 200-0633-00-287-106446. FLUOR NUMBER 5775-CPP-P-51. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
2011-01-01
Background The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. Methods The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Results Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). Conclusions Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency. PMID:21219613
Smith, Gordon Wg; Goldie, Frank; Long, Steven; Lappin, David F; Ramage, Gordon; Smith, Andrew J
2011-01-10
The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency.
Automatic flexible endoscope reprocessors.
Muscarella, L F
2000-04-01
Reprocessing medical instruments is a complex and controversial discipline. If all instruments were constructed of materials not damaged by heat, pressure, and moisture, instrument reprocessing would be greatly simplified. As the number of novel and complex instruments entering the market continues to increase, periodic review of the health care facility's instrument reprocessing protocols to ensure their safety and effectiveness is important. This article reviews the advantages and the limitations of automatic flexible endoscope reprocessors.
LOFT complex in 1975 awaits renewed mission. Aerial view. Camera ...
LOFT complex in 1975 awaits renewed mission. Aerial view. Camera facing southwesterly. Left to right: stack, entry building (TAN-624), door shroud, duct shroud and filter hatches, dome (painted white), pre-amp building, equipment and piping building, shielded control room (TAN-630), airplane hangar (TAN-629). Date: 1975. INEEL negative no. 75-3690 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ETR WASTE GAS EXITED THE ETR COMPLEX FROM THE NORTH ...
ETR WASTE GAS EXITED THE ETR COMPLEX FROM THE NORTH SIDE THROUGH A TUNNEL AND THEN TO A FILTER PIT. TUNNEL EXIT IS UNDER CONSTRUCTION WHILE CONTROL BUILDING IS BEING FORMED BEYOND. CAMERA FACING WEST. INL NEGATIVE NO. 56-1238. Jack L. Anderson, Photographer, 4/17/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
LOFT complex, aerial view taken on same on same day ...
LOFT complex, aerial view taken on same on same day as HAER photo ID-33-E-376. Camera facing south. Note curve of rail track toward hot shop (TAN-607). Earth shielding on control building (TAN-630) is partly removed, showing edge of concrete structure. Great southern butte on horizon. Date: 1975. INEEL negative no. 75-3693 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Reprocessing anesthesia instruments and devices.
Ball, K
2000-02-01
Reprocessing anesthesia instruments and devices can often present a challenge for anesthesia providers because anesthesia devices have become more complex, cross-contamination with disease-forming pathogens can occur, and the importance of appropriate reprocessing may not be fully understood. Based on accepted practice recommendations, regulations, and research, reprocessing must be performed by skilled individuals who understand asepsis, cleaning, disinfection, and sterilization principles. This article describes the art of reprocessing and includes highlighted information on recommended practices, Spaulding's classifications, personal protective attire, precleaning, leak testing of flexible endoscopes, device disassembly, cleaning supplies and solutions, cleaning methods, rinsing, reassembly of the device, inspection, disinfection, and sterilization.
LOFT complex, camera facing west. Mobile entry (TAN624) is position ...
LOFT complex, camera facing west. Mobile entry (TAN-624) is position next to containment building (TAN-650). Shielded roadway entrance in view just below and to right of stack. Borated water tank has been covered with weather shelter and is no longer visible. ANP hangar (TAN-629) in view beyond LOFT. Date: 1974. INEEL negative no. 74-4191 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
9. DETAIL VIEW OF BRIDGE CRANE ON WEST SIDE OF ...
9. DETAIL VIEW OF BRIDGE CRANE ON WEST SIDE OF BUILDING. CAMERA FACING NORTHEAST. CONTAMINATED AIR FILTERS LOADED IN TRANSPORT CASKS WERE TRANSFERRED TO VEHICLES AND SENT TO RADIOACTIVE WASTE MANAGEMENT COMPLEX FOR STORAGE. INEEL PROOF NUMBER HD-17-1. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
ETR COMPLEX. CAMERA FACING SOUTH. FROM BOTTOM OF VIEW TO ...
ETR COMPLEX. CAMERA FACING SOUTH. FROM BOTTOM OF VIEW TO TOP: MTR, MTR SERVICE BUILDING, ETR CRITICAL FACILITY, ETR CONTROL BUILDING (ATTACHED TO ETR), ETR BUILDING (HIGH-BAY), COMPRESSOR BUILDING (ATTACHED AT LEFT OF ETR), HEAT EXCHANGER BUILDING (JUST BEYOND COMPRESSOR BUILDING), COOLING TOWER PUMP HOUSE, COOLING TOWER. OTHER BUILDINGS ARE CONTRACTORS' CONSTRUCTION BUILDINGS. INL NEGATIVE NO. 56-4105. Unknown Photographer, ca. 1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Consolidated fuel reprocessing program
NASA Astrophysics Data System (ADS)
1985-02-01
Improved processes and components for the Breeder Reprocessing Engineering Test (BRET) were identified and developed as well as the design, procurement and development of prototypic equipment. The integrated testing of process equipment and flowsheets prototypical of a pilot scale full reprocessing plant, and also for testing prototypical remote features of specific complex components in the system are provided. Information to guide the long range activities of the Consolidated Fuel Reprocessing Program (CERP), a focal point for foreign exchange activities, and support in specialized technical areas are described. Research and development activities in HTGR fuel treatment technology are being conducted. Head-end process and laboratory scale development efforts, as well as studies specific to HTGR fuel, are reported. The development of off-gas treatment processes has generic application to fuel reprocessing, progress in this work is also reported.
Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices
McDonnell, Gerald
2015-01-01
Inadequate flexible endoscope reprocessing has been associated with infection outbreaks, most recently caused by carbapenem-resistant Enterobacteriaceae. Lapses in essential device reprocessing steps such as cleaning, disinfection/sterilization, and storage have been reported, but some outbreaks have occurred despite claimed adherence to established guidelines. Recommended changes in these guidelines include the use of sterilization instead of high-level disinfection or the use of routine microbial culturing to monitor efficacy of reprocessing. This review describes the current standards for endoscope reprocessing, associated outbreaks, and the complexities associated with both microbiological culture and sterilization approaches to mitigating the risk of infection associated with endoscopy. PMID:26202125
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Shekhar; Koganti, S.B.
2008-07-01
Acetohydroxamic acid (AHA) is a novel complexant for recycle of nuclear-fuel materials. It can be used in ordinary centrifugal extractors, eliminating the need for electro-redox equipment or complex maintenance requirements in a remotely maintained hot cell. In this work, the effect of AHA on Pu(IV) distribution ratios in 30% TBP system was quantified, modeled, and integrated in SIMPSEX code. Two sets of batch experiments involving macro Pu concentrations (conducted at IGCAR) and one high-Pu flowsheet (literature) were simulated for AHA based U-Pu separation. Based on the simulation and validation results, AHA based next-generation reprocessing flowsheets are proposed for co-processing basedmore » FBR and thermal-fuel reprocessing as well as evaporator-less macro-level Pu concentration process required for MOX fuel fabrication. Utilization of AHA results in significant simplification in plant design and simpler technology implementations with significant cost savings. (authors)« less
PBF Reactor Building (PER620). Construction view shows native lava rock ...
PBF Reactor Building (PER-620). Construction view shows native lava rock surrounding basement excavation and general complexity of planning required to build the PBF. A three-inch low-pressure air line protrudes from wall just below left center. Date: February 21, 1967. Photographer: Larry Page. INEEL negative no. 67-1125 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
LOFT/FET complex. Construction view of abutment footings for arches of ...
LOFT/FET complex. Construction view of abutment footings for arches of hangar (TAN-629). Tunnels between basement of hangar and control building (TAN-630) had to fit between arches. (Note concrete work taking place at hole at lower edge of view. This photo may document unexpected bubble in underlying lava rock. It was dumped full of concrete and a footing made. Source: Interview with John DeClue). Date: December 19, 1957. Photographer: Jack L. Anderson. INEEL negative no. 57-6203 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices.
Humphries, Romney M; McDonnell, Gerald
2015-10-01
Inadequate flexible endoscope reprocessing has been associated with infection outbreaks, most recently caused by carbapenem-resistant Enterobacteriaceae. Lapses in essential device reprocessing steps such as cleaning, disinfection/sterilization, and storage have been reported, but some outbreaks have occurred despite claimed adherence to established guidelines. Recommended changes in these guidelines include the use of sterilization instead of high-level disinfection or the use of routine microbial culturing to monitor efficacy of reprocessing. This review describes the current standards for endoscope reprocessing, associated outbreaks, and the complexities associated with both microbiological culture and sterilization approaches to mitigating the risk of infection associated with endoscopy. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jinsuo; Guo, Shaoqiang
Pyroprocessing is a promising alternative for the reprocessing of used nuclear fuel (UNF) that uses electrochemical methods. Compared to the hydrometallurgical reprocessing method, pyroprocessing has many advantages such as reduced volume of radioactive waste, simple waste processing, ability to treat refractory material, and compatibility with fast reactor fuel recycle. The key steps of the process are the electro-refining of the spent metallic fuel in the LiCl-KCl eutectic salt, which can be integrated with an electrolytic reduction step for the reprocessing of spent oxide fuels.
Complementary Reliability-Based Decodings of Binary Linear Block Codes
NASA Technical Reports Server (NTRS)
Fossorier, Marc P. C.; Lin, Shu
1997-01-01
This correspondence presents a hybrid reliability-based decoding algorithm which combines the reprocessing method based on the most reliable basis and a generalized Chase-type algebraic decoder based on the least reliable positions. It is shown that reprocessing with a simple additional algebraic decoding effort achieves significant coding gain. For long codes, the order of reprocessing required to achieve asymptotic optimum error performance is reduced by approximately 1/3. This significantly reduces the computational complexity, especially for long codes. Also, a more efficient criterion for stopping the decoding process is derived based on the knowledge of the algebraic decoding solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dux, Joachim; Friedrich, Daniel; Lutz, Werner
2013-07-01
Decommissioning and dismantling of the former German Pilot Reprocessing Plant Karlsruhe (WAK) including the Vitrification Facility (VEK) is being executed in different Project steps related to the reprocessing, HLLW storage and vitrification complexes /1/. While inside the reprocessing building the total inventory of process equipment has already been dismantled and disposed of, the HLLW storage and vitrification complex has been placed out of operation since vitrification and tank rinsing procedures where finalized in year 2010. This paper describes the progress made in dismantling of the shielded boxes of the highly contaminated laboratory as a precondition to get access to themore » hot cells of the HLLW storage. The major challenges of the dismantling of this laboratory were the high dose rates up to 700 mSv/h and the locking technology for the removal of the hot cell installations. In parallel extensive prototype testing of different carrier systems and power manipulators to be applied to dismantle the HLLW-tanks and other hot cell equipment is ongoing. First experiences with the new manipulator carrier system and a new master slave manipulator with force reflection will be reported. (authors)« less
ETR COMPLEX. CAMERA FACING EAST. FROM LEFT TO RIGHT: ETRCRITICAL ...
ETR COMPLEX. CAMERA FACING EAST. FROM LEFT TO RIGHT: ETR-CRITICAL FACILITY BUILDING, ETR CONTROL BUILDING (ATTACHED TO HIGH-BAY ETR), ETR, ONE-STORY SECTION OF ETR BUILDING, ELECTRICAL BUILDING, COOLING TOWER PUMP HOUSE, COOLING TOWER. COMPRESSOR AND HEAT EXCHANGER BUILDING ARE PARTLY IN VIEW ABOVE ETR. DARK-COLORED DUCTS PROCEED FROM GROUND CONNECTION TO ETR WASTE GAS STACK. OTHER STACK IS MTR STACK WITH FAN HOUSE IN FRONT OF IT. RECTANGULAR STRUCTURE NEAR TOP OF VIEW IS SETTLING BASIN. INL NEGATIVE NO. 56-4102. Unknown Photographer, ca. 1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. ETR COMPLEX NEARLY COMPLETE. CAMERA FACES NORTHWEST, PROBABLY ...
ETR, TRA-642. ETR COMPLEX NEARLY COMPLETE. CAMERA FACES NORTHWEST, PROBABLY FROM TOP DECK OF COOLING TOWER. SHADOW IS CAST BY COOLING TOWER UNITS OFF LEFT OF VIEW. HIGH-BAY REACTOR BUILDING IS SURROUNDED BY ITS ATTACHED SERVICES: ELECTRICAL (TRA-648), HEAT EXCHANGER (TRA-644 WITH U-SHAPED YARD), AND COMPRESSOR (TRA-643). THE CONTROL BUILDING (TRA-647) ON THE NORTH SIDE IS HIDDEN FROM VIEW. AT UPPER RIGHT IS MTR BUILDING, TRA-603. INL NEGATIVE NO. 56-3798. Jack L. Anderson, Photographer, 11/26/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SPERTI Reactor Pit Building (PER605). Earth shielding protect adjacent Instrument ...
SPERT-I Reactor Pit Building (PER-605). Earth shielding protect adjacent Instrument Cell (PER-606). Security fencing surrounds complex, to which gate entry is provided next to Guard House (PER-607). Note gravel road leading to control area. Earth-covered conduit leads from instrument cell to terminal building out of view. Photographer: R.G. Larsen. Date: June 22, 1955. INEEL negative no. 55-1701 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
A&M. Hot liquid waste treatment building (TAN616). Contextual view, facing ...
A&M. Hot liquid waste treatment building (TAN-616). Contextual view, facing south. Wall of hot shop (TAN-607) with high bay at left of view. Lower-roofed building at left edge of view is TAN- 633, hot cell annex. Complex at center of view is TAN-616. Tall metal building with gable roof is TAN-615. Photographer: Ron Paarmann. Date: September 22, 1997. INEEL negative no. HD-20-2-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ETR AND MTR COMPLEXES IN CONTEXT. CAMERA FACING NORTHERLY. FROM ...
ETR AND MTR COMPLEXES IN CONTEXT. CAMERA FACING NORTHERLY. FROM BOTTOM TO TOP: ETR COOLING TOWER, ELECTRICAL BUILDING AND LOW-BAY SECTION OF ETR BUILDING, HEAT EXCHANGER BUILDING (WITH U SHAPED YARD), COMPRESSOR BUILDING. MTR REACTOR SERVICES BUILDING IS ATTACHED TO SOUTH WALL OF MTR. WING A IS ATTACHED TO BALCONY FLOOR OF MTR. NEAR UPPER RIGHT CORNER OF VIEW IS MTR PROCESS WATER BUILDING. WING B IS AT FAR WEST END OF COMPLEX. NEAR MAIN GATE IS GAMMA FACILITY, WITH "COLD" BUILDINGS BEYOND: RAW WATER STORAGE TANKS, STEAM PLANT, MTR COOLING TOWER PUMP HOUSE AND COOLING TOWER. INL NEGATIVE NO. 56-4101. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
CONTEXTUAL AERIAL VIEW OF "COLD" NORTH HALF OF MTR COMPLEX. ...
CONTEXTUAL AERIAL VIEW OF "COLD" NORTH HALF OF MTR COMPLEX. CAMERA FACING EASTERLY. FOREGROUND CORNER CONTAINS OIL STORAGE TANKS. WATER TANKS AND WELL HOUSES ARE BEYOND THEM TO THE LEFT. LARGE LIGHT-COLORED BUILDING IN CENTER OF VIEW IS STEAM PLANT. DEMINERALIZER AND WATER STORAGE TANK ARE BEYOND. SIX-CELL COOLING TOWER AND ITS PUMP HOUSE ARE ABOVE IT IN VIEW. SERVICE BUILDINGS INCLUDING CANTEEN ARE ON NORTH SIDE OF ROAD. "EXCLUSION" AREA IS BEYOND ROAD. COMPARE LOCATION OF EXCLUSION-AREA GATE WITH PHOTO ID-33-G-202. INL NEGATIVE NO. 3608. Unknown Photographer, 10/30/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Modeling to Evaluate Coordination and Flexibility in Aluminum Recycling Operations
NASA Astrophysics Data System (ADS)
Brommer, Tracey; Olivetti, Elsa; Fjeldbo, Snorre; Kirchain, Randolph
Reprocessing of aluminum production byproducts or dross for use in secondary production presents a particular challenge to the aluminum industry. While use of these non-traditional secondary materials is of interest due to their reduced energy and economic burden over virgin counterparts, these materials necessitate the use of particular furnaces, specialized handling and processing conditions. Therefore, to make use of them firms may pursue use of an intermediate recycling facility that can reprocess the secondary materials into a liquid product. After reprocessing downstream aluminum remelters could incorporate the liquid products into their aluminum alloy production schedules. Energy and environmental benefits result from delivering the products as liquid but coordination challenges result because of the energy cost to maintain the liquid. Further coordination challenges result from the need to establish long term recycling production plans in the presence of long term downstream aluminum remelter production uncertainty and inherent variation in the daily order schedule of the downstream aluminum remelters. In this context a fundamental question arises, considering the metallurgical complexities of dross reprocessing, what is the value of operating a coordinated set of by-product reprocessing plants and remelting cast houses?
Optimizing Endoscope Reprocessing Resources Via Process Flow Queuing Analysis.
Seelen, Mark T; Friend, Tynan H; Levine, Wilton C
2018-05-04
The Massachusetts General Hospital (MGH) is merging its older endoscope processing facilities into a single new facility that will enable high-level disinfection of endoscopes for both the ORs and Endoscopy Suite, leveraging economies of scale for improved patient care and optimal use of resources. Finalized resource planning was necessary for the merging of facilities to optimize staffing and make final equipment selections to support the nearly 33,000 annual endoscopy cases. To accomplish this, we employed operations management methodologies, analyzing the physical process flow of scopes throughout the existing Endoscopy Suite and ORs and mapping the future state capacity of the new reprocessing facility. Further, our analysis required the incorporation of historical case and reprocessing volumes in a multi-server queuing model to identify any potential wait times as a result of the new reprocessing cycle. We also performed sensitivity analysis to understand the impact of future case volume growth. We found that our future-state reprocessing facility, given planned capital expenditures for automated endoscope reprocessors (AERs) and pre-processing sinks, could easily accommodate current scope volume well within the necessary pre-cleaning-to-sink reprocessing time limit recommended by manufacturers. Further, in its current planned state, our model suggested that the future endoscope reprocessing suite at MGH could support an increase in volume of at least 90% over the next several years. Our work suggests that with simple mathematical analysis of historic case data, significant changes to a complex perioperative environment can be made with ease while keeping patient safety as the top priority.
Modernization at the Y-12 National Security Complex: A Case for Additional Experimental Benchmarks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornbury, Matthew
Electrorefining (ER) is a major part of efforts at the Y-12 National Security Complex to revolutionize the reprocessing and purification of enriched uranium (EU). Successful implementation of ER could drastically reduce the operational costs and footprint, hazardous materials use, and waste generation.
Effects of reuse and bleach/formaldehyde reprocessing on polysulfone and polyamide hemodialyzers.
Cornelius, Rena M; McClung, W Glenn; Barre, Paul; Esguerra, Fe; Brash, John L
2002-01-01
The surface features, morphology, and blood interactions of fibers from pristine, bleach/formaldehyde reprocessed, and reused Fresenius Polysulfone High Flux (Hemoflow F80B) hemodialyzers and Gambro Polyflux 21S Polyamide hemodialyzers have been studied. SEM images of fibers from both hemodialyzer types revealed a dense skin layer on the inner surface and a relatively thick porous layer on the outer surface. The 21S polyamide support layer consisted of interconnected highly porous structures. Environmental scanning electron microscopy and atomic force microscopy images of both membrane types showed alterations in morphology due to reprocessing and reuse; however the changes were more marked for the 21S polyamide dialyzers. Fluorescence microscopy images showed only minimal fluorescence associated with the fibers after patient use and reprocessing, suggesting that blood derived deposits were removed by processing. The protein layers formed on pristine and reused hemodialyzer membranes during clinical use were studied using SDS-PAGE and immunoblotting. Before bleach/formaldehyde treatment, protein layers of considerable amount and complexity were found on the blood side of singly and multiply used dialyzers. Proteins adsorbed on the dialysate side were predominantly in the molecular mass region below 30 kDa. However, some higher molecular mass proteins were detected on the dialysate side of the 21 S polyamide dialyzers. Very little protein was detected on dialyzers that were treated with bleach/formaldehyde after dialysis, regardless of whether they had been used/reprocessed once or 12 times.
H.M. never again! An analysis of H.M.'s epilepsy and treatment.
Mauguière, F; Corkin, S
2015-03-01
On August 25, 1953, the patient H.M., aged 27, underwent a bilateral surgical destruction of the inner aspect of his temporal lobes performed by William Beecher Scoville with the aim to control H.M.'s drug refractory epileptic seizures and alleviate their impact on his quality of life. Postoperatively, H.M. presented for 55 years a "striking and totally unexpected grave loss of recent memories". This paper reports what we know about H.M.'s epilepsy before and after surgery and puts forward arguments supporting the syndromic classification of his epilepsy. We attempted to elucidate what could have been the rationale, in 1953, of Scoville's decision to carry out a bilateral ablation of H.M.'s medial temporal lobe structures, and we examined whether there was any convincing argument published before 1953 suggesting that bilateral hippocampal ablation could result in a permanent and severe amnesia. Our a posteriori analysis of H.M.'s medical history suggested that he was most probably suffering from idiopathic generalized epilepsy with absences and generalized convulsive seizures worsened by high dosage phenytoin treatment, or less probably from cryptogenic frontal lobe epilepsy. Importantly, he did not have temporal lobe epilepsy. Scoville based his proposal of bilateral mesial temporal lobe ablation on his experience as a psychosurgeon and on the assumption that the threshold of generalized epileptic activity could be lowered by some kind of hippocampal dysfunction potentially epileptic in nature. Given the scanty information on the link between amnesia and medial temporal lobe lesions that was available in humans in 1953, one can understand why Scoville was so surprised by the "striking and totally unexpected" memory loss he observed in H.M. after the bilateral ablation of his mesial temporal lobe structures. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
EOS Data Products Latency and Reprocessing Evaluation
NASA Astrophysics Data System (ADS)
Ramapriyan, H. K.; Wanchoo, L.
2012-12-01
NASA's Earth Observing System (EOS) Data and Information System (EOSDIS) program has been processing, archiving, and distributing EOS data since the launch of Terra platform in 1999. The EOSDIS Distributed Active Archive Centers (DAACs) and Science-Investigator-led Processing Systems (SIPSs) are generating over 5000 unique products with a daily average volume of 1.7 Petabytes. Initially EOSDIS had requirements to make process data products within 24 hours of receiving all inputs needed for generating them. Thus, generally, the latency would be slightly over 24 and 48 hours after satellite data acquisition, respectively, for Level 1 and Level 2 products. Due to budgetary constraints these requirements were relaxed, with the requirement being to avoid a growing backlog of unprocessed data. However, the data providers have been generating these products in as timely a manner as possible. The reduction in costs of computing hardware has helped considerably. It is of interest to analyze the actual latencies achieved over the past several years in processing and inserting the data products into the EOSDIS archives for the users to support various scientific studies such as land processes, oceanography, hydrology, atmospheric science, cryospheric science, etc. The instrument science teams have continuously evaluated the data products since the launches of EOS satellites and improved the science algorithms to provide high quality products. Data providers have periodically reprocessed the previously acquired data with these improved algorithms. The reprocessing campaigns run for an extended time period in parallel with forward processing, since all data starting from the beginning of the mission need to be reprocessed. Each reprocessing activity involves more data than the previous reprocessing. The historical record of the reprocessing times would be of interest to future missions, especially those involving large volumes of data and/or computational loads due to complexity of algorithms. Evaluation of latency and reprocessing times requires some of the product metadata information, such as the beginning and ending time of data acquisition, processing date, and version number. This information for each product is made available by data providers to the ESDIS Metrics System (EMS). The EMS replaced the earlier ESDIS Data Gathering and Reporting System (EDGRS) in FY2005. Since then it has collected information about data products' ingest, archive, and distribution. The analysis of latencies and reprocessing times will provide an insight to the data provider process and identify potential areas of weakness in providing timely data to the user community. Delays may be caused by events such as system unavailability, disk failures, delay in level 0 data delivery, availability of input data, network problems, and power failures. Analysis of metrics will highlight areas for focused examination of root causes for delays. The purposes of this study are to: 1) perform a detailed analysis of latency of selected instrument products for last 6 years; 2) analyze the reprocessed data from various data providers to determine the times taken for reprocessing campaigns; 3) identify potential reasons for any anomalies in these metrics.
Method for cleaning solution used in nuclear fuel reprocessing
Tallent, O.K.; Crouse, D.J.; Mailen, J.C.
1980-12-17
Nuclear fuel processing solution consisting of tri-n-butyl phosphate and dodecane, with a complex of uranium, plutonium, or zirconium and with a solvent degradation product such as di-n-butyl phosphate therein, is contacted with an aqueous solution of a salt formed from hydrazine and either a dicarboxylic acid or a hydroxycarboxylic acid, thereby removing the aforesaid complex from the processing solution.
Method for cleaning solution used in nuclear fuel reprocessing
Tallent, Othar K.; Crouse, David J.; Mailen, James C.
1982-01-01
Nuclear fuel processing solution consisting of tri-n-butyl phosphate and dodecane, with a complex of uranium, plutonium, or zirconium and with a solvent degradation product such as di-n-butyl phosphate therein, is contacted with an aqueous solution of a salt formed from hydrazine and either a dicarboxylic acid or a hydroxycarboxylic acid, thereby removing the aforesaid complex from the processing solution.
Industrial research for transmutation scenarios
NASA Astrophysics Data System (ADS)
Camarcat, Noel; Garzenne, Claude; Le Mer, Joël; Leroyer, Hadrien; Desroches, Estelle; Delbecq, Jean-Michel
2011-04-01
This article presents the results of research scenarios for americium transmutation in a 22nd century French nuclear fleet, using sodium fast breeder reactors. We benchmark the americium transmutation benefits and drawbacks with a reference case consisting of a hypothetical 60 GWe fleet of pure plutonium breeders. The fluxes in the various parts of the cycle (reactors, fabrication plants, reprocessing plants and underground disposals) are calculated using EDF's suite of codes, comparable in capabilities to those of other research facilities. We study underground thermal heat load reduction due to americium partitioning and repository area minimization. We endeavor to estimate the increased technical complexity of surface facilities to handle the americium fluxes in special fuel fabrication plants, americium fast burners, special reprocessing shops, handling equipments and transport casks between those facilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graf, Wilhelm
Since in 1984 the national reprocessing concept was abandoned the reprocessing abroad was the only existing disposal route until 1994. With the amendment of the Atomic Energy Act in 2001 spent fuel management changed completely since from 1 June 2005 any delivery of spent fuel to reprocessing plants was prohibited and the direct disposal of spent fuel became mandatory. Until 2005 the total amount of spent fuel to be reprocessed abroad added up to 6080 t HM, 5309 t HM thereof in France. The waste generated from reprocessing - alternatively an equivalent amount of radioactive material - has to bemore » returned to the country of origin according to the commercial contracts signed between the German utilities and COGEMA, now AREVA NC, in France and BNFL, now INS in UK. In addition the German and the French government exchanged notes with the obligation of both sides to enable and support the return of reprocessing residues or equivalents to Germany. The return of high active vitrified waste from La Hague to the interim storage facility at Gorleben was demanding from the technical view i. e. the cask design and the transport. Unfortunately the Gorleben area served as a target for nuclear opponents from the first transport in 1996 to the latest one in 2011. The protection against sabotage of the railway lines and mass protests needed highly improved security measures. In France and Germany special working forces and projects have been set up to cope with this extraordinary situation. A complex transport organization was established to involve all parties in line with the German and French requirements during transport. The last transport of vitrified residues from France has been completed successfully so far thus confirming the efficiency of the applied measures. Over 15 years there was and still is worldwide no comparable situation it is still unique. Summing up, the exceptional project handling challenge that resulted from the continuous anti-nuclear civil disobedience in Germany over the whole 15-year long project running time could be faced efficiently. It has to be concluded that despite of all problems the anti-nuclear activities have caused so far, all transports of vitrified HLW have always been completed successfully by adapting the commonly established safety, security and public acceptance measures to the special conditions and needs in Germany and coordinating the activities of all parties involved but at the expense of high costs for industry and government and a challenging operational complexity. Apart from an anticipatory project planning a good communication between all involved industrial parties and the French and the German government was the key to the effective management of such shipments and to minimize the radiological, economic, environmental, public and political impact. The future will show how efficiently the gained experience can be used for further return projects which are to be realized since no reprocessed waste has yet been returned from UK and neither the medium-level nor the low-level radioactive waste has been transferred from France to Germany. (author)« less
Ethical and hygiene aspects of the reprocessing of medical devices in Germany
Kramer, Axel; Assadian, Ojan
2008-01-01
Based on safety and quality principles, for each medical device (MD), regardless of its declared status as single- or multi-use device, careful considerations must be made. This includes assessment whether reprocessing is economical and ecological meaningful, and technical feasible. So far, however, in Germany reprocessing of declared single use MD is legally allowed, provided that the above aspects are well covered. The purpose of this paper is to elucidate, when circumstances allow reprocessing of declared single-use MD. For reprocessing of single use MD the following preconditions must be fulfilled: The security level of the reprocessed MD must be equivalent to the status of the newly delivered item; this means that a patient is not exposed to a higher risk through a reprocessed disposable MD than through the new, i.e. un-processed product. The reprocessing must be based on a detailed risk assessment and risk analysis, and must be described in detail regarding selection of the reprocessing method. Additionally, all necessary safety- and quality assurance measures must be stated. The reprocessing measure needs to be accompanied with a quality management system which determines and documents the responsibility of all stages of reprocessing; where the corresponding reprocessing procedures are well defined; and the efficacy of the procedure is proven by product-specific or product-group-specific tests and reports. The process must be validated according to recognised methods of science and technology, taking into account potential negative influences of the reprocessing on the properties of the material and the technical and functional safety. For reprocessing of MDs of the category Critical C the quality assurance must be certified by an accredited certifying body. PMID:20204097
24. CONSTRUCTION PROGRESS VIEW TO NORTHWEST, SHOWING BLOWER BUILDING. INEEL ...
24. CONSTRUCTION PROGRESS VIEW TO NORTHWEST, SHOWING BLOWER BUILDING. INEEL PHOTO NUMBER NRTS-60-4407. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
23. CONSTRUCTION PROGRESS VIEW LOOKING TOWARD EAST SHOWING CONCRETE BLOCK ...
23. CONSTRUCTION PROGRESS VIEW LOOKING TOWARD EAST SHOWING CONCRETE BLOCK CONSTRUCTION. INEEL PHOTO NUMBER NRTS-59-4305. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
15. CONSTRUCTION PROGRESS PHOTO SHOWING FORMS GOING UP ON ACCESS ...
15. CONSTRUCTION PROGRESS PHOTO SHOWING FORMS GOING UP ON ACCESS CORRIDOR. INEEL PHOTO NUMBER NRTS-59-336. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
X-ray-binary spectra in the lamp post model
NASA Astrophysics Data System (ADS)
Vincent, F. H.; Różańska, A.; Zdziarski, A. A.; Madej, J.
2016-05-01
Context. The high-energy radiation from black-hole binaries may be due to the reprocessing of a lamp located on the black hole rotation axis and emitting X-rays. The observed spectrum is made of three major components: the direct spectrum traveling from the lamp directly to the observer; the thermal bump at the equilibrium temperature of the accretion disk heated by the lamp; and the reflected spectrum essentially made of the Compton hump and the iron-line complex. Aims: We aim to accurately compute the complete reprocessed spectrum (thermal bump + reflected) of black-hole binaries over the entire X-ray band. We also determine the strength of the direct component. Our choice of parameters is adapted to a source showing an important thermal component. We are particularly interested in investigating the possibility to use the iron-line complex as a probe to constrain the black hole spin. Methods: We computed in full general relativity the illumination of a thin accretion disk by a fixed X-ray lamp along the rotation axis. We used the ATM21 radiative transfer code to compute the local, energy-dependent spectrum emitted along the disk as a function of radius, emission angle and black hole spin. We then ray traced this local spectrum to determine the final reprocessed spectrum as received by a distant observer. We consider two extreme values of the black hole spin (a = 0 and a = 0.98) and discuss the dependence of the local and ray-traced spectra on the emission angle and black hole spin. Results: We show the importance of the angle dependence of the total disk specific intensity spectrum emitted by the illuminated atmosphere when the thermal disk emission is fully taken into account. The disk flux, together with the X-ray flux from the lamp, determines the temperature and ionization structure of the atmosphere. High black hole spin implies high temperature in the inner disk regions, therefore, the emitted thermal disk spectrum fully covers the iron-line complex. As a result, instead of fluorescent iron emission line, we locally observe absorption lines produced in the hot disk atmosphere. Absorption lines are narrow and disappear after ray tracing the local spectrum. Conclusions: Our results mainly highlight the importance of considering the angle dependence of the local spectrum when computing reprocessed spectra, as was already found in a recent study. The main new result of our work is to show the importance of computing the thermal bump of the spectrum, as this feature can change considerably the observed iron-line complex. Thus, in particular for fitting black hole spins, the full spectrum, rather than only the reflected part, should be computed self-consistently.
20. CONSTRUCTION PROGRESS PHOTO OF INSTRUMENT PANEL IN PLACE IN ...
20. CONSTRUCTION PROGRESS PHOTO OF INSTRUMENT PANEL IN PLACE IN OPERATING CORRIDOR. INEEL PHOTO NUMBER NRTS-59-6091. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venkataraman, M.; Natarajan, R.; Raj, Baldev
The reprocessing of spent fuel from Fast Breeder Test Reactor (FBTR) has been successfully demonstrated in the pilot plant, CORAL (COmpact Reprocessing facility for Advanced fuels in Lead shielded cell). Since commissioning in 2003, spent mixed carbide fuel from FBTR of different burnups and varying cooling period, have been reprocessed in this facility. Reprocessing of the spent fuel with a maximum burnup of 100 GWd/t has been successfully carried out so far. The feed backs from these campaigns with progressively increasing specific activities, have been useful in establishing a viable process flowsheet for reprocessing the Prototype Fast Breeder Reactor (PFBR)more » spent fuel. Also, the design of various equipments and processes for the future plants, which are either under design for construction, namely, the Demonstration Fast Reactor Fuel Reprocessing Plant (DFRP) and the Fast reactor fuel Reprocessing Plant (FRP) could be finalized. (authors)« less
NASA Astrophysics Data System (ADS)
Yoon, S.
2016-12-01
To define geodetic reference frame using GPS data collected by Continuously Operating Reference Stations (CORS) network, historical GPS data needs to be reprocessed regularly. Reprocessing GPS data collected by upto 2000 CORS sites for the last two decades requires a lot of computational resource. At National Geodetic Survey (NGS), there has been one completed reprocessing in 2011, and currently, the second reprocessing is undergoing. For the first reprocessing effort, in-house computing resource was utilized. In the current second reprocessing effort, outsourced cloud computing platform is being utilized. In this presentation, the outline of data processing strategy at NGS is described as well as the effort to parallelize the data processing procedure in order to maximize the benefit of the cloud computing. The time and cost savings realized by utilizing cloud computing approach will also be discussed.
29. FET 601312 VIEW OF TELEVISION DOLLY IN ...
29. FET 60-1312 VIEW OF TELEVISION DOLLY IN TAN 629 HANGAR, AN ASPECT OF INSTRUMENTATION. PHOTO DATE: MARCH 23, 1960. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
42. ARAIII Prototype assembly and evaluation building ARA630 interior. Typical ...
42. ARA-III Prototype assembly and evaluation building ARA-630 interior. Typical view room partitions. Ineel photo no. 3-28. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
21. CONSTRUCTION PROGRESS VIEW OF CALCINER VESSEL ON LOW BOY ...
21. CONSTRUCTION PROGRESS VIEW OF CALCINER VESSEL ON LOW BOY EN ROUTE TO FACILITY. INEEL PHOTO NUMBER NRTS-60-2487. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
22. CONSTRUCTION PROGRESS PHOTO SHOWING WORKERS LOWERING CALCINER VESSEL INTO ...
22. CONSTRUCTION PROGRESS PHOTO SHOWING WORKERS LOWERING CALCINER VESSEL INTO CELL THROUGH THE HATCH. INEEL PHOTO NUMBER NRTS-60-2485. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
35. MISCELLANEOUS ARCHITECTURAL AND STRUCTURAL DETAILS. INEEL DRAWING NUMBER 200063300287106359. ...
35. MISCELLANEOUS ARCHITECTURAL AND STRUCTURAL DETAILS. INEEL DRAWING NUMBER 200-0633-00-287-106359. FLUOR NUMBER 5775-CPP-633-A-9. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
34. DOOR AND WINDOW DETAILS. INEEL DRAWING NUMBER 200063300287106358. FLUOR ...
34. DOOR AND WINDOW DETAILS. INEEL DRAWING NUMBER 200-0633-00-287-106358. FLUOR NUMBER 5775-CPP-633-A-8. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
33. ROOF PLAN AND DETAILS. INEEL DRAWING NUMBER 200063300287106357. FLUOR ...
33. ROOF PLAN AND DETAILS. INEEL DRAWING NUMBER 200-0633-00-287-106357. FLUOR NUMBER 5775-CPP-633-A-7. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
PBF (PER620) interior, basement level. Sampling equipment. Date: May 2004. ...
PBF (PER-620) interior, basement level. Sampling equipment. Date: May 2004. INEEL negative no. HD-41-5-4 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
IET. Weather instrumentation tower, located south of control building. Camera ...
IET. Weather instrumentation tower, located south of control building. Camera facing west. Date: August 17, 1955. INEEL negative no. 55-2414 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET control building (TAN620). interior room. sign says, "emergency equipment ...
IET control building (TAN-620). interior room. sign says, "emergency equipment for metal fires." INEEL negative no. HD-21-1-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PBF (PER620) interior. Counting room, main floor. Date: May 2004. ...
PBF (PER-620) interior. Counting room, main floor. Date: May 2004. INEEL negative no. HD-41-6-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
A&M. Hot liquid waste building (TAN616). Interior of evaporator control ...
A&M. Hot liquid waste building (TAN-616). Interior of evaporator control room. Date: 1962. INEEL negative no. 62-6824 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Isaacson, Dylan; Ahmad, Tessnim; Metzler, Ian; Tzou, David T; Taguchi, Kazumi; Usawachintachit, Manint; Zetumer, Samuel; Sherer, Benjamin; Stoller, Marshall; Chi, Thomas
2017-10-01
Careful decontamination and sterilization of reusable flexible ureteroscopes used in ureterorenoscopy cases prevent the spread of infectious pathogens to patients and technicians. However, inefficient reprocessing and unavailability of ureteroscopes sent out for repair can contribute to expensive operating room (OR) delays. Time-driven activity-based costing (TDABC) was applied to describe the time and costs involved in reprocessing. Direct observation and timing were performed for all steps in reprocessing of reusable flexible ureteroscopes following operative procedures. Estimated times needed for each step by which damaged ureteroscopes identified during reprocessing are sent for repair were characterized through interviews with purchasing analyst staff. Process maps were created for reprocessing and repair detailing individual step times and their variances. Cost data for labor and disposables used were applied to calculate per minute and average step costs. Ten ureteroscopes were followed through reprocessing. Process mapping for ureteroscope reprocessing averaged 229.0 ± 74.4 minutes, whereas sending a ureteroscope for repair required an estimated 143 minutes per repair. Most steps demonstrated low variance between timed observations. Ureteroscope drying was the longest and highest variance step at 126.5 ± 55.7 minutes and was highly dependent on manual air flushing through the ureteroscope working channel and ureteroscope positioning in the drying cabinet. Total costs for reprocessing totaled $96.13 per episode, including the cost of labor and disposable items. Utilizing TDABC delineates the full spectrum of costs associated with ureteroscope reprocessing and identifies areas for process improvement to drive value-based care. At our institution, ureteroscope drying was one clearly identified target area. Implementing training in ureteroscope drying technique could save up to 2 hours per reprocessing event, potentially preventing expensive OR delays.
ETR ELECTRICAL BUILDING, TRA648, INTERIOR. SWITCHGEAR. INL NEGATIVE NO. 563794. ...
ETR ELECTRICAL BUILDING, TRA-648, INTERIOR. SWITCHGEAR. INL NEGATIVE NO. 56-3794. Jack L. Anderson, Photographer, 11/26/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR ELECTRICAL BUILDING, TRA648. BATTERY ROOM. INL NEGATIVE NO. 563785. ...
ETR ELECTRICAL BUILDING, TRA-648. BATTERY ROOM. INL NEGATIVE NO. 56-3785. Jack L. Anderson, Photographer, 11/26/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
WORKER STACKS GRAPHITE BLOCKS AGAINST INNER SOUTH WALL OF REACTOR. ...
WORKER STACKS GRAPHITE BLOCKS AGAINST INNER SOUTH WALL OF REACTOR. INL NEGATIVE NO. 3925. Unknown Photographer, 12/14/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
27. ELEVATIONS OF EAST AND WEST SIDES. INEEL DRAWING NUMBER ...
27. ELEVATIONS OF EAST AND WEST SIDES. INEEL DRAWING NUMBER 200-0633-00-287-106355. FLUOR NUMBER 5775-CPP-633-A-5. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
28. NORTH AND SOUTH ELEVATIONS AND TWO SECTIONS. INEEL DRAWING ...
28. NORTH AND SOUTH ELEVATIONS AND TWO SECTIONS. INEEL DRAWING NUMBER 200-0633-00-287-106356. FLUOR NUMBER 5775-CPP-633-A-6. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
IET. Jet fuel tank being lowered into position below grade. ...
IET. Jet fuel tank being lowered into position below grade. Two tanks already in place. Date: October 18, 1954. INEEL negative no. 12535 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
52. ARAII. Support piers for SL1 reactor building. September 5, ...
52. ARA-II. Support piers for SL-1 reactor building. September 5, 1957. Ineel photo no. 57-4398. Photographer: Ken Mansfield. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF (PER620) interior, first basement level. Sampling equipment. Date: March ...
PBF (PER-620) interior, first basement level. Sampling equipment. Date: March 2004. INEEL negative no. HD-41-4-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI, Instrument Cell Building (PER606). North facade. Date: August 2003. ...
SPERT-I, Instrument Cell Building (PER-606). North facade. Date: August 2003. INEEL negative no. HD-35-3-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) interior, basement level. Detail of coolant piping. Date: ...
PBF (PER-620) interior, basement level. Detail of coolant piping. Date: May 2004. INEEL negative no. HD-41-5-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
19. INTERIOR VIEW INSIDE BUNKER SHOWING NITROGEN TANKS, 'MOBILE AIR ...
19. INTERIOR VIEW INSIDE BUNKER SHOWING NITROGEN TANKS, 'MOBILE AIR MONITOR' EQUIPMENT, MAN. INEL PHOTO NUMBER 65-6183, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
IET. Diesel engine for emergency generator is headed for installation ...
IET. Diesel engine for emergency generator is headed for installation in shielded control building (TAN-620). Date: September 21, 1954. INEEL negative no. 12145 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Hot liquid waste building (TAN616) under construction. Camera facing ...
A&M. Hot liquid waste building (TAN-616) under construction. Camera facing northeast. Date: November 25, 1953. INEEL negative no. 9232 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
19. INTERIOR OF TAN 629 HANGAR, TAKEN ON LOW ROOF ...
19. INTERIOR OF TAN 629 HANGAR, TAKEN ON LOW ROOF ON WEST SIDE, FACING EAST. DETAIL OF HANGAR DOOR LEAVES. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. INSIDE A FLASH EVAPORATOR. INL NEGATIVE ...
PROCESS WATER BUILDING, TRA-605. INSIDE A FLASH EVAPORATOR. INL NEGATIVE NO. 3323. Unknown Photographer, 9/12/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
16. CONSTRUCTION PROGRESS PHOTO SHOWING SURPLUS GUN BARREL BEING LOWERED ...
16. CONSTRUCTION PROGRESS PHOTO SHOWING SURPLUS GUN BARREL BEING LOWERED INTO PLACE FOR USE AS PIPE TUNNEL. INEEL PHOTO NUMBER NRTS-59-709. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
25. CONSTRUCTION PROGRESS AERIAL VIEW OF WASTE CALCINING FACILITY TAKEN ...
25. CONSTRUCTION PROGRESS AERIAL VIEW OF WASTE CALCINING FACILITY TAKEN WHEN STRUCTURE WAS 99 PERCENT COMPLETE. INEEL PHOTO NUMBER NRTS-60-5409. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
18. CONSTRUCTION PROGRESS PHOTO SHOWING SURPLUS GUN BARRELS IN PLACE ...
18. CONSTRUCTION PROGRESS PHOTO SHOWING SURPLUS GUN BARRELS IN PLACE TO BE USED AS PIPE TUNNELS. INEEL PHOTO NUMBER NRTS-59-925. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
Surface evaluation of cardiac angiographic catheters after simulated use and reprocessing
NASA Astrophysics Data System (ADS)
Lucas, Thabata Coaglio; Oréfice, Rodrigo Lambert; Pinotti, Marcos; Huebner, Rudolf
2009-12-01
Reprocessing of single-use intravascular catheters is a common practice in public health services and hospitals. The determination of safe number of reprocessing cycles before the catheter integrity becomes compromised has been a priority issue. The present paper addresses the evaluating molecular and micro-structural integrity of reprocessed cardiac angiographic catheters. The Fourier Transform Infrared Spectroscopy and Scanning Electron Microscopy were carried out to elucidate morphological changes. The tensile test was performed on catheters to examine changes in bulk characteristics. In this work, samples of catheters were reprocessed until nine times and sterilized by hydrogen peroxide plasma. It was observed that the number of hydrogen-bonded carbonyls groups increased in 0.05 u.a. ( p < 0.001) after each reprocessing cycle. The spectra indicated degradation products included acids, esters, alcohols, and small amounts of other products containing a carbonyl functional group. The micrographs revealed that only after the fourth reprocessing cycle the effect increased in the surface roughness was more pronounced. On the other hand, after each reprocessing cycle and as consequence of extensive aging of polyamide/polyurethane blends of the catheters surface, it was observed that the micro-fissures, micro-scratches and micro-pores increased in quantity and length. The mechanical test proved that the Young modulus increased in average 3.26 MPa ( p = 0.0003) at increasing number of reprocessing cycles, also suggestive of crosslinking in this material.
Flory-Stockmayer analysis on reprocessable polymer networks
NASA Astrophysics Data System (ADS)
Li, Lingqiao; Chen, Xi; Jin, Kailong; Torkelson, John
Reprocessable polymer networks can undergo structure rearrangement through dynamic chemistries under proper conditions, making them a promising candidate for recyclable crosslinked materials, e.g. tires. This research field has been focusing on various chemistries. However, there has been lacking of an essential physical theory explaining the relationship between abundancy of dynamic linkages and reprocessability. Based on the classical Flory-Stockmayer analysis on network gelation, we developed a similar analysis on reprocessable polymer networks to quantitatively predict the critical condition for reprocessability. Our theory indicates that it is unnecessary for all bonds to be dynamic to make the resulting network reprocessable. As long as there is no percolated permanent network in the system, the material can fully rearrange. To experimentally validate our theory, we used a thiol-epoxy network model system with various dynamic linkage compositions. The stress relaxation behavior of resulting materials supports our theoretical prediction: only 50 % of linkages between crosslinks need to be dynamic for a tri-arm network to be reprocessable. Therefore, this analysis provides the first fundamental theoretical platform for designing and evaluating reprocessable polymer networks. We thank McCormick Research Catalyst Award Fund and ISEN cluster fellowship (L. L.) for funding support.
Characteristics of potential repository wastes. Volume 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-07-01
The LWR spent fuels discussed in Volume 1 of this report comprise about 99% of all domestic non-reprocessed spent fuel. In this report we discuss other types of spent fuels which, although small in relative quantity, consist of a number of diverse types, sizes, and compositions. Many of these fuels are candidates for repository disposal. Some non-LWR spent fuels are currently reprocessed or are scheduled for reprocessing in DOE facilities at the Savannah River Site, Hanford Site, and the Idaho National Engineering Laboratory. It appears likely that the reprocessing of fuels that have been reprocessed in the past will continuemore » and that the resulting high-level wastes will become part of defense HLW. However, it is not entirely clear in some cases whether a given fuel will be reprocessed, especially in cases where pretreatment may be needed before reprocessing, or where the enrichment is not high enough to make reprocessing attractive. Some fuels may be canistered, while others may require special means of disposal. The major categories covered in this chapter include HTGR spent fuel from the Fort St. Vrain and Peach Bottom-1 reactors, research and test reactor fuels, and miscellaneous fuels, and wastes generated from the decommissioning of facilities.« less
Endoscope reprocessing methods: a prospective study on the impact of human factors and automation.
Ofstead, Cori L; Wetzler, Harry P; Snyder, Alycea K; Horton, Rebecca A
2010-01-01
The main cause of endoscopy-associated infections is failure to adhere to reprocessing guidelines. More information about factors impacting compliance is needed to support the development of effective interventions. The purpose of this multisite, observational study was to evaluate reprocessing practices, employee perceptions, and occupational health issues. Data were collected utilizing interviews, surveys, and direct observation. Written reprocessing policies and procedures were in place at all five sites, and employees affirmed the importance of most recommended steps. Nevertheless, observers documented guideline adherence, with only 1.4% of endoscopes reprocessed using manual cleaning methods with automated high-level disinfection versus 75.4% of those reprocessed using an automated endoscope cleaner and reprocessor. The majority reported health problems (i.e., pain, decreased flexibility, numbness, or tingling). Physical discomfort was associated with time spent reprocessing (p = .041). Discomfort diminished after installation of automated endoscope cleaners and reprocessors (p = .001). Enhanced training and accountability, combined with increased automation, may ensure guideline adherence and patient safety while improving employee satisfaction and health.
McGuire, Tracy M; Lee, Christopher W; Drummond, Peter D
2014-01-01
Post-traumatic stress disorder (PTSD) continues to attract both empirical and clinical interest due to its complex symptom profile and the underlying processes involved. Recently, research attention has been focused on the types of memory processes involved in PTSD and hypothesized neurobiological processes. Complicating this exploration, and the treatment of PTSD, are underlying comorbid disorders, such as depression, anxiety, and substance use disorders. Treatment of PTSD has undergone further reviews with the introduction of eye movement desensitization and reprocessing (EMDR). EMDR has been empirically demonstrated to be as efficacious as other specific PTSD treatments, such as trauma-focused cognitive behavioral therapy. There is emerging evidence that there are different processes underlying these two types of trauma treatment and some evidence that EMDR might have an efficiency advantage. Current research and understanding regarding the processes of EMDR and the future direction of EMDR is presented.
GRAPHITE BLOCKS ARE ARRAYED IN "THERMAL COLUMN" ON NORTH SIDE ...
GRAPHITE BLOCKS ARE ARRAYED IN "THERMAL COLUMN" ON NORTH SIDE OF REACTOR. INL NEGATIVE NO. 4000. Unknown Photographer, 12/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
41. OPERATING CORRIDOR PLAN AND SECTIONS, INCLUDING SOME ISOMETRIC DETAILS. ...
41. OPERATING CORRIDOR PLAN AND SECTIONS, INCLUDING SOME ISOMETRIC DETAILS. INEEL DRAWING NUMBER 200-0633-00-287-106455. FLUOR NUMBER 5775-CPP-633-P-60 - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
PBF Reactor Building (PER620). Fuel rod test assembly is on ...
PBF Reactor Building (PER-620). Fuel rod test assembly is on display at PBF. Date: 1982. INEEL negative no. 82-4893 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) interior. System control racks, secondary control and equipment ...
PBF (PER-620) interior. System control racks, secondary control and equipment room. Date: May 2004. INEEL negative no. HD-41-6-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI, Instrument Cell Building (PER606). West facade. Camera facing northeast. ...
SPERT-I, Instrument Cell Building (PER-606). West facade. Camera facing northeast. Date: August 2003. INEEL negative no. HD-35-3-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI, Instrument Cell Building (PER606). East facade. Camera facing southwest. ...
SPERT-I, Instrument Cell Building (PER-606). East facade. Camera facing southwest. Date: August 2003. INEEL negative no. HD-35-3-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
74. ARAII. Dr. William Zinn of combustion engineering company and ...
74. ARA-II. Dr. William Zinn of combustion engineering company and others at controls of SL-1. August 8, 1959. Ineel photo no. 59-4109. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
IET. Stack interior. Masons lay fire brick liner, leaving air ...
IET. Stack interior. Masons lay fire brick liner, leaving air layer between bricks and concrete wall. Date: May 20, 1955. INEEL negative no. 55-1306 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
MTR BASEMENT. GENERAL ELECTRIC CONTROL CONSOLE FOR AIRCRAFT NUCLEAR PROPULSION ...
MTR BASEMENT. GENERAL ELECTRIC CONTROL CONSOLE FOR AIRCRAFT NUCLEAR PROPULSION EXPERIMENT NO. 1. INL NEGATIVE NO. 6510. Unknown Photographer, 9/29/1959 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PRECAST CONCRETE WALL PANELS ARE LIFTED INTO PLACE ON MTR ...
PRECAST CONCRETE WALL PANELS ARE LIFTED INTO PLACE ON MTR STEEL FRAME STRUCTURE. INL NEGATIVE NO. 1330. Unknown Photographer, 1/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
FAST CHOPPER BUILDING, TRA665, INTERIOR. UPPER LEVEL. CONCRETE WALLS. INL ...
FAST CHOPPER BUILDING, TRA-665, INTERIOR. UPPER LEVEL. CONCRETE WALLS. INL NEGATIVE NO. HD42-2. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Commercial Nuclear Reprocessing in the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherrill, Charles Leland; Balatsky, Galya Ivanovna
2015-09-09
The short presentation outline: Reprocessing Overview; Events leading up to Carter’s Policy; Results of the decision; Policy since Nuclear Nonproliferation Act. Conclusions reached: Reprocessing ban has become an easy and visible fix to the public concern about proliferation, but has not completely stopped proliferation; and, Reprocessing needs to become detached from political considerations, so technical research can continue, regardless of the policy decisions we decide to take.
Reprocessing of research reactor fuel the Dounreay option
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cartwright, P.
1997-08-01
Reprocessing is a proven process for the treatment of spent U/Al Research Reactor fuel. At Dounreay 12679 elements have been reprocessed during the past 30 years. For reactors converting to LEU fuel the uranium recovered in reprocessing can be blended down to less than 20% U{sub 235}, enrichment and be fabricated into new elements. For reactors already converted to LEU it is technically possible to reprocess spent silicide fuel to reduce the U{sub 235} burden and present to a repository only stable conditioned waste. The main waste stream from reprocessing which contains the Fission products is collected in underground storagemore » tanks where it is kept for a period of at least five years before being converted to a stable solid form for return to the country of origin for subsequent storage/disposal. Discharges to the environment from reprocessing are low and are limited to the radioactive gases contained in the spent fuel and a low level liquid waste steam. Both of these discharges are independently monitored, and controlled within strict discharge limits set by the UK Government`s Scottish Office. Transportation of spent fuel to Dounreay has been undertaken using many routes from mainland Europe and has utilised over the past few years both chartered and scheduled vessel services. Several different transport containers have been handled and are currently licensed in the UK. This paper provides a short history of MTR reprocessing at Dounreay, and provides information to show reprocessing can satisfy the needs of MTR operators, showing that reprocessing is a valuable asset in non-proliferation terms, offers a complete solution and is environmentally acceptable.« less
Effectiveness of reprocessing for flexible bronchoscopes and endobronchial ultrasound bronchoscopes.
Ofstead, Cori L; Quick, Mariah R; Wetzler, Harry P; Eiland, John E; Heymann, Otis L; Sonetti, David A; Ferguson, J Scott
2018-05-30
Infections have been linked to inadequately-reprocessed flexible bronchoscopes, and recent investigations determined that pathogen transmission occurred even when bronchoscope cleaning and disinfection practices aligned with current guidelines. This multisite, prospective study evaluated the effectiveness of real-world bronchoscope reprocessing methods using a systematic approach. This study involved direct observation of reprocessing methods for flexible bronchoscopes, multifaceted evaluations performed after manual cleaning and after high-level disinfection, and assessments of storage conditions. Visual inspections of ports and channels were performed using lighted magnification and borescopes. Contamination was detected using microbial cultures and tests for protein, hemoglobin, and adenosine triphosphate. Researchers assessed reprocessing practices, and storage cabinet cleanliness was evaluated by visual inspection and adenosine triphosphate tests. Researchers examined 24 clinically used bronchoscopes. After manual cleaning, 100% of bronchoscopes had residual contamination. Microbial growth was found in 14 (58%) fully-reprocessed bronchoscopes, including mold, Stenotrophomonas maltophilia, and Escherichia coli/Shigella spp. Visible irregularities were observed in 100% of bronchoscopes, including retained fluid; brown, red, or oily residue; scratches; damaged insertion tubes and distal ends; and filamentous debris in channels. Reprocessing practices were substandard at two of three sites. Damaged and contaminated bronchoscopes were in use at all sites. Inadequate reprocessing practices may have contributed to bioburden found on bronchoscopes. However, even when guidelines were followed, high-level disinfection was not effective. A shift toward the use of sterilized bronchoscopes is recommended. In the meantime, quality management programs and updated reprocessing guidelines are needed. Copyright © 2018. Published by Elsevier Inc.
Gloves Reprocessing: Does It Really Save Money?
Arora, Pankaj; Kumari, Santosh; Sodhi, Jitender; Talati, Shweta; Gupta, Anil Kumar
2015-12-01
Gloves are reprocessed and reused in health-care facilities in resource-limited settings to reduce the cost of availability of gloves. The study was done with the aim to compute the cost of reprocessing of gloves so that an economically rationale decision can be taken. A retrospective record-based cross-sectional study was undertaken in a central sterile supply department where different steps during reprocessing of gloves were identified and the cost involved in reprocessing per pair of gloves was calculated. The cost of material and manpower was calculated to arrive at the cost of reprocessing per pair of gloves. The cost of a reprocessed pair of surgical gloves was calculated to be Indian Rupee (INR) 14.33 which was greater than the cost of a new pair of disposable surgical gloves (INR 9.90) as the cost of sterilization of one pair of gloves itself came out to be INR 10.97. The current study showed that the purchase of sterile disposable single-use gloves is cheaper than the process of recycling. Reprocessing of gloves is not economical on tangible terms even in resource-limited settings, and from the perspective of better infection control as well as health-care worker safety, it further justifies the use of disposable gloves.
41. ARAIII Prototype assembly and evaluation building ARA630. West end ...
41. ARA-III Prototype assembly and evaluation building ARA-630. West end and south side of building. Camera facing northeast. Ineel photo no. 3-22. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
38. DETAIL OF CYLINDER LEVELING SYSTEM SHOWING TYPICAL UPPER AND ...
38. DETAIL OF CYLINDER LEVELING SYSTEM SHOWING TYPICAL UPPER AND LOWER PULLEY BRACKET. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-8. INEL INDEX CODE - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
LOFT. "Exploded view" of loft containment building (TAN650), including control ...
LOFT. "Exploded view" of loft containment building (TAN-650), including control building (TAN-630). EG&G. February 1979. INEEL index code no. 036-010-65-220-209565 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
104. ARAIII. Interior view of room 110 in ARA607 used ...
104. ARA-III. Interior view of room 110 in ARA-607 used as data acquisition control room. Camera facing northeast. Ineel photo no. 81-103. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
IET. Typical detail during Snaptran reactor experiments. Shielding bricks protect ...
IET. Typical detail during Snaptran reactor experiments. Shielding bricks protect ion chamber beneath reactor on dolly. Photographer: Page Comiskey. Date: August 11, 1965. INEEL negative no. 65-4039 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
MTR CONTROL ROOM WITH CONTROL CONSOLE AND STATUS READOUTS ALONG ...
MTR CONTROL ROOM WITH CONTROL CONSOLE AND STATUS READOUTS ALONG WALL. WORKERS MAKE ELECTRICAL AND OTHER CONNECTIONS. INL NEGATIVE NO. 4289. Unknown Photographer, 2/26/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
8. ARAI Shop and maintenance building ARA627 interior view. Remains ...
8. ARA-I Shop and maintenance building ARA-627 interior view. Remains of cabinetry and electrical switch panel in one of rooms. Ineel photo no. 1-11. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
IET control building (TAN620). interior personnel service room. sign next ...
IET control building (TAN-620). interior personnel service room. sign next to shower stall says, "fight athlete's foot with sani-mist." INEEL negative no. HD-21-1-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
29. FLOOR PLAN OF WASTE CALCINATION FACILITY SHOWING MAIN ABOVEGRADE ...
29. FLOOR PLAN OF WASTE CALCINATION FACILITY SHOWING MAIN ABOVE-GRADE FLOOR LEVEL. INEEL DRAWING NUMBER 200-0633-00-287-106354. FLUOR NUMBER 5775-CPP-633-A-4. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
PBF Reactor Building (PER620). PBF crane holds fuel test assembly ...
PBF Reactor Building (PER-620). PBF crane holds fuel test assembly aloft prior to lowering into reactor for test. Date: 1982. INEEL negative no. 82-4909 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SOUTH WING, TRA661. SOUTH SIDE. CAMERA FACING NORTH. MTR HIGH ...
SOUTH WING, TRA-661. SOUTH SIDE. CAMERA FACING NORTH. MTR HIGH BAY BEYOND. INL NEGATIVE NO. HD46-45-3. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR HEAT EXCHANGER BUILDING, TRA644. WORKERS ARE INSTALLING HEAT EXCHANGER ...
ETR HEAT EXCHANGER BUILDING, TRA-644. WORKERS ARE INSTALLING HEAT EXCHANGER PIPING. INL NEGATIVE NO. 56-3122. Jack L. Anderson, Photographer, 9/21/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SPERTI Control Building (PER601) floor plan. Detail of cable inlet. ...
SPERT-I Control Building (PER-601) floor plan. Detail of cable inlet. Idaho Operations Office. Date: February 1955. INEEL index no. 760-0601-00-396-109139 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Cooling Tower (PER720). Camera faces south to show north ...
PBF Cooling Tower (PER-720). Camera faces south to show north facade. Note enclosed stairway. Date: August 2003. INEEL negative no. HD-35-10-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Canal takes shape, with rebar and ...
PBF Reactor Building (PER-620). Canal takes shape, with rebar and concrete placement underway. Photographer: John Capek. Date: August 16, 1967. INEEL negative no. 67-4370 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Cooling Tower (PER720). Closeup detail of louvered wall panels ...
PBF Cooling Tower (PER-720). Close-up detail of louvered wall panels on south facade. Date: August 2003. INEEL negative no. HD-35-11-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
LPT. Shield test facility (TAN645) interior. Mechanical equipment room with ...
LPT. Shield test facility (TAN-645) interior. Mechanical equipment room with switchgear and control boards. Photographer: Jack L. Anderson. Date: February 20, 1959. INEEL negative no. 59-858 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
80. ARAIII. Forming of the mechanical equipment pit in reactor ...
80. ARA-III. Forming of the mechanical equipment pit in reactor building (ARA-608). Camera facing northwest. September 22, 1958. Ineel photo no. 58-4675. Photographer: Jack L. Anderson. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
LPT. Shield test facility (TAN645) interior. Mechanical equipment room with ...
LPT. Shield test facility (TAN-645) interior. Mechanical equipment room with airwasher and refrigeration compressor. Photographer: Jack L. Anderson. Date: February 20, 1959. INEEL negative no. 59-855 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
51. ARAII. Camera looking southeast at foundation piers for SL1 ...
51. ARA-II. Camera looking southeast at foundation piers for SL-1 reactor building support. August 22, 1957. Ineel photo no. 57-4212. Photographer: Jack L. Anderson. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
15. VIEW OF DUMMY FUEL ELEMENT ON FUEL ELEMENT HOLDER. ...
15. VIEW OF DUMMY FUEL ELEMENT ON FUEL ELEMENT HOLDER. SHOWS AIR FORCE MAN AT EDGE OF TANK. INEL PHOTO NUMBER 65-6176, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
PBF Control Building auxiliary features, including fire hose house and ...
PBF Control Building auxiliary features, including fire hose house and sewage system. Ebasco Services 1205 PER/PER-A-4. INEEL undex no. 760-0619-00-205-123024 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ETR COMPRESSOR BUILDING, TRA643. COMPRESSORS AND OTHER EQUIPMENT INSTALLED. METAL ...
ETR COMPRESSOR BUILDING, TRA-643. COMPRESSORS AND OTHER EQUIPMENT INSTALLED. METAL ROOF AND CONCRETE BLOCK WALLS. INL NEGATIVE NO. 61-4536. Unknown Photographer, ca. 1961. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. Radioactive parts security storage area. camera facing northwest. Outdoor ...
A&M. Radioactive parts security storage area. camera facing northwest. Outdoor storage of concrete storage casks. Photographer: M. Holmes. Date: November 21, 1959. INEEL negative no. 59-6081 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
38. SECTIONS OF ACCESS CORRIDOR, INCLUDES SECTION SHOWING ARRANGEMENT OF ...
38. SECTIONS OF ACCESS CORRIDOR, INCLUDES SECTION SHOWING ARRANGEMENT OF NAVY GUN BARRELS. INEEL DRAWING NUMBER 200-0633-00-287-106454. FLUOR NUMBER 5775-CPP-633-P-59. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
A&M. Hot liquid waste holding tanks. Camera faces southeast. Located ...
A&M. Hot liquid waste holding tanks. Camera faces southeast. Located in vicinity of TAN-616, hot liquid waste treatment plant. Date: November 13, 1953. INEEL negative no. 9159 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
24. ARAIII Reactor building ARA608 interior. Camera facing south. Chalk ...
24. ARA-III Reactor building ARA-608 interior. Camera facing south. Chalk marks on wall indicate presence or absence of spot contamination. Ineel photo no. 3-2. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
Using eye movement desensitization and reprocessing to enhance treatment of couples.
Protinsky, H; Sparks, J; Flemke, K
2001-04-01
Eye Movement Desensitization and Reprocessing (EMDR) as a clinical technique may enhance treatment effectiveness when applied within a couple therapy approach that is emotionally and experientially oriented. Clinical experience indicates that EMDR-based interventions are useful for accessing, activating, tolerating, and reprocessing the intense emotions that often fuel dysfunctional couple interactions. Using EMDR within conjoint sessions to reprocess negative emotions can amplify intimacy, increase connection, and subsequently lead to a change in problematic relationship patterns.
Case outsourcing medical device reprocessing.
Haley, Deborah
2004-04-01
IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.
Maroufi, Mohsen; Zamani, Shahla; Izadikhah, Zahra; Marofi, Maryam; O'Connor, Peter
2016-09-01
To investigate the efficacy of Eye Movement Desensitization and Reprocessing for postoperative pain management in adolescents. Eye Movement Desensitization and Reprocessing is an inexpensive, non-pharmacological intervention that has successfully been used to treat chronic pain. It holds promise in the treatment of acute, postsurgical pain based on its purported effects on the brain and nervous system. A randomized controlled trial was used. Fifty-six adolescent surgical patients aged between 12-18 years were allocated to gender-balanced Eye Movement Desensitization and Reprocessing (treatment) or non-Eye Movement Desensitization and Reprocessing (control) groups. Pain was measured using the Wong-Baker FACES(®) Pain Rating Scale (WBFS) before and after the intervention (or non-intervention for the control group). A Wilcoxon signed-rank test demonstrated that the Eye Movement Desensitization and Reprocessing group experienced a significant reduction in pain intensity after treatment intervention, whereas the control group did not. Additionally, a Mann-Whitney U-test showed that, while there was no significant difference between the two groups at time 1, there was a significant difference in pain intensity between the two groups at time 2, with the Eye Movement Desensitization and Reprocessing group experiencing lower levels of pain. These results suggest that Eye Movement Desensitization and Reprocessing may be an effective treatment modality for postoperative pain. © 2016 John Wiley & Sons Ltd.
Effects of heat/citric acid reprocessing on high-flux polysulfone dialyzers.
Cornelius, Rena M; McClung, W Glenn; Richardson, Robert M A; Estridge, Charles; Plaskos, Nicholas; Yip, Christopher M; Brash, John L
2002-01-01
The surface features, morphology, and tensile properties of fibers obtained from pristine, reprocessed, and reused Fresenius Polysulfone High-Flux (Hemoflow F80A) hemodialyzers have been studied. Scanning electron microscopy of the dialyzer fibers revealed a dense skin layer on the inner surface of the membrane and a relatively thick porous layer on the outer surface. Transmission electron microscopy and atomic force microscopy showed an alteration in membrane morphology due to reprocessing and reuse, or to a deposition of blood-borne material on the membrane that is not removed with reprocessing. Fluorescent microscopy images also showed that a fluorescent material not removed by heat/citric acid reprocessing builds up with continued use of the dialyzers. The tensile properties of the dialyzer fibers were not affected by the heat/citric acid reprocessing procedure. The protein layers formed on pristine and reused hemodialyzer membranes during clinical use were also studied using sodium dodecyl sulfate polyacrylamide gel electrophoresis and immunoblotting. A considerable amount of protein was found on the blood side of single and multiple use dialyzers. Proteins adsorbed on the dialysate side of the membrane were predominantly in the molecular weight region below 30 kDa. Little protein was detected on the membranes of reprocessed hemodialyzers.
76 FR 45268 - Reprocessing of Reusable Medical Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-28
... personal information provided. For additional information on submitting comments, see the ``Comments... problems in all steps of medical device reprocessing,\\1\\ including cleaning, disinfecting, and sterilizing... following issues: 1. What are the nature, scope, and impact of reusable medical device reprocessing problems...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demori, R.; Mauler, R. S., E-mail: raquel.mauler@ufrgs.br; Ashton, E.
Mechanical recycling of polymeric materials is a favorable technique resulting in economic and environmental benefits, especially in the case of polymers with a high production volume as the polypropylene copolymer (PP). However, recycling by reprocessing techniques can lead to thermal, mechanical or thermo-oxidative degradation that can affect the structure of the polymer and subsequently the material properties. PP filled with montmorillonite (MMT) or talc are widely produced and studied, however, its degradation reactions by reprocessing cycles are poorly studied so far. In this study, the effects of reprocessing cycles in the structure and in the properties of the PP/MMT andmore » PP/Talc were evaluated. The samples were mixed with 5% talc or MMT Cloisite C15A in a twin-screw extrusion. After extrusion, this filled material was submitted to five reprocessing cycles through an injection molding process. In order to evaluate the changes induced by reprocessing techniques, the samples were characterized by DSC, FT-IR, Izod impact and tensile strength tests. The study showed that Young modulus, elongation at brake and Izod impact were not affected by reprocessing cycles, except when using talc. In this case, the elongation at brake reduced until the fourth cycle, showing rigidity increase. The DSC results showed that melting and crystallization temperature were not affected. A comparison of FT-IR spectra of the reprocessed indicated that in both samples, between the first and the fifth cycle, no noticeable change has occurred. Thus, there is no evidence of thermo oxidative degradation. In general, these results suggest that PP reprocessing cycles using MMT or talc does not change the material properties until the fifth cycle.« less
Reprocessing and reuse of urological armamentarium: How correct are we!
Raval, Krutik Vipulbhai; Chaudhari, Rajeev; Khant, Shahil Rameshbhai; Joglekar, Omkar; Patel, Dipen
2017-01-01
Healthcare is expensive for a large proportion of the population in spite of high per capita income and good health insurance penetration. In an effort to reduce cost of the procedure, reprocessing of devices was started in the late 1970s. Reprocessing practice includes various measures such as proper cleaning, disinfection, and sterilization procedures. As reprocessing is aimed at reducing cost, there is a potential risk of compromising patient safety due to cross contamination after inadequate sterilization. There is also risk of performance alteration of urological reprocessed devices during sterilization/disinfection processing. Therefore, there is a need for formulating proper guidelines to decide methods of reprocessing for various urological equipment. There is also need to discuss the problematic areas that urologists face and to find their solutions. A PubMed search was made in September 2016, using key words “reprocessing of medical devices,” “Single Use Devices,” “methods of reprocessing of devices in clinical practice,” “use of formalin chamber,” “urological disposable sterilization,” etc., After excluding duplicates, all English articles were reviewed by title and abstract. Full texts of selected articles were obtained, and these articles were cross-referenced to find any other related articles. All the articles were reviewed. A product can be reused if it can be economically reprocessed with validated protocols with preservation of its function. There is no reason to discard it after one use. This practice is useful for controlling economics of a urological case and to reduce the financial burden. Current Food and Drug Administration guidelines are stringent. The contamination described to test the sterilization process in the suggested guidelines actually does never exist in clinical practice. Therefore, new guidelines considering the clinical practice scenario are desirable. PMID:28479760
Conversion of radioactive ferrocyanide compounds to immobile glasses
Schulz, Wallace W.; Dressen, A. Louise
1977-04-26
Complex radioactive ferrocyanide compounds result from the scavenging of cesium from waste products produced in the chemical reprocessing of nuclear fuel. These ferrocyanides, in accordance with this process, are converted to an immobile glass, resistant to leaching by water, by fusion together with sodium carbonate and a mixture of (a) basalt and boron trioxide (B.sub.2 O.sub.3) or (b) silica (SiO.sub.2) and lime (CaO).
LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...
LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Low power test control building (TAN641) east facade. Sign ...
LPT. Low power test control building (TAN-641) east facade. Sign says "Energy and Systems Technology Laboratory, INEL" (Post-ANP-use). Camera facing west. INEEL negative no. HD-40-3-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
12. PHOTOGRAPH OF A PHOTOGRAPH OF A SCALE MODEL OF ...
12. PHOTOGRAPH OF A PHOTOGRAPH OF A SCALE MODEL OF THE WASTE CALCINER FACILITY, SHOWING WEST ELEVATION. (THE ORIGINAL MODEL HAS BEEN LOST.) INEEL PHOTO NUMBER 95-903-1-3. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
3. CONTEXTUAL VIEW OF WASTE CALCINING FACILITY, CAMERA FACING NORTHEAST. ...
3. CONTEXTUAL VIEW OF WASTE CALCINING FACILITY, CAMERA FACING NORTHEAST. SHOWS RELATIONSHIP BETWEEN DECONTAMINATION ROOM, ADSORBER REMOVAL HATCHES (FLAT ON GRADE), AND BRIDGE CRANE. INEEL PROOF NUMBER HD-17-2. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
20. VIEW OF TEST FACILITY IN 1967 WHEN EQUIPPED FOR ...
20. VIEW OF TEST FACILITY IN 1967 WHEN EQUIPPED FOR DOSIMETER TEST BY HEALTH PHYSICISTS. CAMERA FACING EAST. INEL PHOTO NUMBER 76-2853, TAKEN MAY 16, 1967. PHOTOGRAPHER: CAPEK. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
31. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS ACCESS CORRIDOR ...
31. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS ACCESS CORRIDOR AT MEZZANINE AND LOWER LEVELS. INEEL DRAWING NUMBER 200-0633-00-287-106352. FLUOR NUMBER 5775-CPP-633-A-2. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
34. DETAILS AND SECTIONS OF SHIELDING TANK FUEL ELEMENT SUPPORT ...
34. DETAILS AND SECTIONS OF SHIELDING TANK FUEL ELEMENT SUPPORT FRAME. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-4. INEL INDEX CODE NUMBER: 075 0701 60 851 151978. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
139. ARAIII Index of drwaings of gascooled reactor experiment buildings. ...
139. ARA-III Index of drwaings of gas-cooled reactor experiment buildings. Aerojet-general 880-area/GCRE-100. Date: February 1958. Ineel index code no. 063-9999-80-013-102505. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
105. ARAIII. Interior view of ARA608 highbay pit in 1983 ...
105. ARA-III. Interior view of ARA-608 high-bay pit in 1983 modified to contain high-temperature, high-pressure autoclave and furnace test area. Ineel photo no. 81-109. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
SPERTI Control Building (PER601). Elevations. Note cable inlet on west ...
SPERT-I Control Building (PER-601). Elevations. Note cable inlet on west elevation. Idaho Operations Office. Date: February 1955. INEEL index no. 760-0601-00-396-109143 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Floor at left of view is ...
PBF Reactor Building (PER-620). Floor at left of view is floor of first basement. Photographer: Farmer/Capek. Date: March 17, 1967. INEEL negative no. 67-1753 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Cooling Tower detail. Camera facing southwest. Wood fill rises ...
PBF Cooling Tower detail. Camera facing southwest. Wood fill rises from foundation piers of cold water basin. Photographer: Kirsh. Date: May 1, 1969. INEEL negative no. 69-2826 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) west facade. Camera facing east. Note 1980 addition ...
PBF (PER-620) west facade. Camera facing east. Note 1980 addition on south side of west wall. Date: March 2004. INEEL negative no. HD-41-3-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI, Instrument Cell Building (PER606). Oblique view of north and ...
SPERT-I, Instrument Cell Building (PER-606). Oblique view of north and east facades. Camera facing southwest. Date: August 2003. INEEL negative no. HD-35-4-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
6. CONSTRUCTION PROGRESS VIEW (EXTERIOR) OF TANK, CABLE CHASE, AND ...
6. CONSTRUCTION PROGRESS VIEW (EXTERIOR) OF TANK, CABLE CHASE, AND MOUNDED BUNKER. CONSTRUCTION WAS 99 PERCENT COMPLETE. CAMERA IS FACING WEST. INEL PHOTO NUMBER 65-5435, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
ETRMTR MECHANICAL SERVICES BUILDING, TRA653. CAMERA FACING NORTHWEST AS BUILDING ...
ETR-MTR MECHANICAL SERVICES BUILDING, TRA-653. CAMERA FACING NORTHWEST AS BUILDING WAS NEARLY COMPLETE. INL NEGATIVE NO. 57-3653. K. Mansfield, Photographer, 7/22/1957 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. TAN607. Special equipment services room. Workers are filling viewing ...
A&M. TAN-607. Special equipment services room. Workers are filling viewing window with zinc bromide through tube penetrating concrete shield wall. Date: August 16, 1954. INEEL negative no. 11689 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
17. INTERIOR VIEW INSIDE BUNKER. MAN SEATED AT LEFT LOOKS ...
17. INTERIOR VIEW INSIDE BUNKER. MAN SEATED AT LEFT LOOKS AT OPENING TO CABLE CHASE, HIS HANDS ON MANUALLY-OPERATED PULLEY. INEL PHOTO NUMBER 65-6179, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
3. VIEW OF ARVFS BUNKER TAKEN FROM APPROXIMATELY 150 FEET ...
3. VIEW OF ARVFS BUNKER TAKEN FROM APPROXIMATELY 150 FEET EAST OF BUNKER DOOR. CAMERA FACING WEST. VIEW SHOWS EARTH MOUND COVERING CONTROL BUNKER AND REMAINS OF CABLE CHASE. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
A&M. Special shielding materials. Stockpile of magnetite, used for making ...
A&M. Special shielding materials. Stockpile of magnetite, used for making high-density concrete, and loading conveyor near TAN-607 construction site. Date: September 25, 1953. INEEL negative no. 8710 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
FAST CHOPPER BUILDING, TRA665. DETAIL OF STEEL DOOR ENTRY TO ...
FAST CHOPPER BUILDING, TRA-665. DETAIL OF STEEL DOOR ENTRY TO LOWER LEVEL. CAMERA FACING NORTH. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Kooyman, Timothée; Buiron, Laurent; Rimpault, Gerald
2018-05-01
In the heterogeneous minor actinides transmutation approach, the nuclei to be transmuted are loaded in dedicated targets often located at the core periphery, so that long-lived heavy nuclides are turned into shorter-lived fission products by fission. To compensate for low flux level at the core periphery, the minor actinides content in the targets is set relatively high (around 20 at.%), which has a negative impact on the reprocessing of the targets due to their important decay heat level. After a complete analysis of the main contributors to the heat load of the irradiated targets, it is shown here that the choice of the reprocessing order of the various feeds of americium from the fuel cycle depends on the actual limit for fuel reprocessing. If reprocessing of hot targets is possible, it is more interesting to reprocess first the americium feed with a high 243Am content in order to limit the total cooling time of the targets, while if reprocessing of targets is limited by their decay heat, it is more interesting to wait for an increase in the 241Am content before loading the americium in the core. An optimization of the reprocessing order appears to lead to a decrease of the total cooling time by 15 years compared to a situation where all the americium feeds are mixed together when two feeds from SFR are considered with a high reprocessing limit.
Complexation of lanthanides and actinides by acetohydroxamic acid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, R.J.; Sinkov, S.I.; Choppin, G.R.
2008-07-01
Acetohydroxamic acid (AHA) has been proposed as a suitable reagent for the complexant-based, as opposed to reductive, stripping of plutonium and neptunium ions from the tributylphosphate solvent phase in advanced PUREX or UREX processes designed for future nuclear-fuel reprocessing. Stripping is achieved by the formation of strong hydrophilic complexes with the tetravalent actinides in nitric acid solutions. To underpin such applications, knowledge of the complexation constants of AHA with all relevant actinide (5f) and lanthanide (4f) ions is therefore important. This paper reports the determination of stability constants of AHA with the heavier lanthanide ions (Dy-Yb) and also U(IV) andmore » Th(IV) ions. Comparisons with our previously published AHA stability-constant data for 4f and 5f ions are made. (authors)« less
SAFETY AND SECURITY BUILDING, TRA614. ELEVATIONS. SECTIONS. TWO ROOF LEVELS. ...
SAFETY AND SECURITY BUILDING, TRA-614. ELEVATIONS. SECTIONS. TWO ROOF LEVELS. BLAW-KNOX 3150-814-2, 3/1950. INL INDEX NO. 531-0614-00-098-100703, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SAFETY AND SECURITY BUILDING, TRA614. SIMPLIFIED FLOOR LAYOUT AND WEST ...
SAFETY AND SECURITY BUILDING, TRA-614. SIMPLIFIED FLOOR LAYOUT AND WEST ELEVATION. BLAW-KNOX 3150-14-1, 1/1950. INL INDEX NO. 531-0614-00-098-100024, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. FLASH EVAPORATOR, CONDENSER (PROJECT FROM EVAPORATOR), ...
PROCESS WATER BUILDING, TRA-605. FLASH EVAPORATOR, CONDENSER (PROJECT FROM EVAPORATOR), AND STEAM EJECTOR (ALONG REAR WALL). INL NEGATIVE NO. 4377. M.H. Bartz, Photographer, 3/5/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
30. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS LEVELS ABOVE ...
30. FLOOR PLANS OF WASTE CALCINATION FACILITY. SHOWS LEVELS ABOVE GRADE AND AT LEVEL OF OPERATING CORRIDOR. INEEL DRAWING NUMBER 200-0633-00-287-106351. FLUOR NUMBER 5775-CPP-633-A-1. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
146. ARAIII Control building (ARA607) Roof plan and details. Aerojetgeneral ...
146. ARA-III Control building (ARA-607) Roof plan and details. Aerojet-general 880-area/GCRE-607-A-3. Date: February 1958. Ineel index code no. 063-0607-00-013-102548. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
33. DETAILS OF SAMPLE SUPPORT FRAME ASSEMLBY, LIFTING LUG, AND ...
33. DETAILS OF SAMPLE SUPPORT FRAME ASSEMLBY, LIFTING LUG, AND SAMPLE CARRIER ROD. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-5. INEL INDEX CODE NUMBER: 075 0701 60 851 151979. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
PBF (PER620) north facade. Camera facing south. Small metal shed ...
PBF (PER-620) north facade. Camera facing south. Small metal shed at right is Stack Gas Monitor Building, PER-629. Date: March 2004. INEEL negative no. HD-41-2-4 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
37. PLAN OF ACCESS CORRIDOR PIPING INCLUDES WASTE HOLD TANK ...
37. PLAN OF ACCESS CORRIDOR PIPING INCLUDES WASTE HOLD TANK CELL, OFFGAS CELL, ADSORBER CELL, AND OFFGAS FILTER CELL. INEEL DRAWING NUMBER 200-0633-00-287-106453. FLUOR NUMBER 5775-CPP-P-58. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
97. ARAIII. ML1 reactor has been moved into GCRE reactor ...
97. ARA-III. ML-1 reactor has been moved into GCRE reactor building (ARA-608) for examination of corrosion on its underside and repair. May 24, 1963. Ineel photo no. 63-3485. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
FAN HOUSE INTERIOR. THREE MOTOR DRIVES FOR POSITIVE DISPLACEMENT BLOWERS ...
FAN HOUSE INTERIOR. THREE MOTOR DRIVES FOR POSITIVE DISPLACEMENT BLOWERS LINE UP ON NORTH WALL. CONCRETE PEDESTALS. CAMERA FACES NORTHEAST. INL NEGATIVE NO. 4291. Unknown Photographer, 2/26/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID ...
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID NOT EXPLAIN DARK CLOUD. MTR WING WILL ATTACH TO GROUND FLOOR. INL NEGATIVE NO. 1567. Unknown Photographer, 2/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
170. ARAIV Blast bunker installed after ML1 buildings were removed. ...
170. ARA-IV Blast bunker installed after ML-1 buildings were removed. Isometric detail and section. EG&G Company. Date: June 1985. Ineel index code no. 066-0600-60-220-166261. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
LOFT. Containment and service building (TAN650). Roof plan and details. ...
LOFT. Containment and service building (TAN-650). Roof plan and details. Kaiser engineers 6413-11-STEP/LOFT-650-A-8. Date: October 1964. INEEL index code no. 036-650-00-486-122220 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
34. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING NORTH ...
34. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING NORTH AND SOUTH ELEVATIONS. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-629-A-3. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
166. ARAIII Fire hose houses (Probably numbered on site as ...
166. ARA-III Fire hose houses (Probably numbered on site as ARA-624). Aerojet-general 880-area/GCRE-701-S-4. Date: February 1958. Ineel index code no. 063-0624-00-013-102695. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Control Building (PER619). Interior in data acquisition room showing ...
PBF Control Building (PER-619). Interior in data acquisition room showing data racks. The system recorded multiple channels of data during tests. INEEL negative no. HD-41-8-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. BASEMENT. LIQUID SODIUM PIPING INSIDE CUBICLE ...
ETR BUILDING, TRA-642, INTERIOR. BASEMENT. LIQUID SODIUM PIPING INSIDE CUBICLE SHOWN IN ID-33-G-101. INL NEGATIVE NO. HD24-3-4. Mike Crane, Photographer, 11/2000 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. Hot liquid waste treatment building (TAN616). Camera facing east. ...
A&M. Hot liquid waste treatment building (TAN-616). Camera facing east. Showing west facades of structure. Photographer: Ron Paarmann. Date: September 22, 1997. INEEL negative no. HD-20-1-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET control building (TAN620). equipment removed. Lube oil and waste ...
IET control building (TAN-620). equipment removed. Lube oil and waste piping at upper right. Fire door on right. Rebar exposed in concrete of ceiling. INEEL negative no. HD-21-5-3 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PBF Control Building (PER619) south facade. Camera faces north. Note ...
PBF Control Building (PER-619) south facade. Camera faces north. Note buried tanks with bollards protecting their access hatches. Date: July 2004. INEEL negative no. HD-41-10-4 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
...] Draft Guidance for Industry and FDA Staff: Processing/ Reprocessing Medical Devices in Health Care... Devices in Health Care Settings: Validation Methods and Labeling.'' The recommendations in this guidance... Staff: Processing/Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling...
Using Eye Movement Desensitization and Reprocessing To Enhance Treatment of Couples.
ERIC Educational Resources Information Center
Protinsky, Howard; Sparks, Jennifer; Flemke, Kimberly
2001-01-01
Eye Movement Desensitization and Reprocessing (EMDR) as a clinical technique may enhance treatment effectiveness when applied in couple therapy that is emotionally and experientially oriented. Clinical experience indicates EMDR-based interventions are useful for accessing and reprocessing intense emotions in couple interactions. EMDR can amplify…
Reprocessing system with nuclide separation based on chromatography in hydrochloric acid solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, Tatsuya; Tachibana, Yu; Koyama, Shi-ichi
2013-07-01
We have proposed the reprocessing system with nuclide separation processes based on the chromatographic technique in the hydrochloric acid solution system. Our proposed system consists of the dissolution process, the reprocessing process, the minor actinide separation process, and nuclide separation processes. In the reprocessing and separation processes, the pyridine resin is used as a main separation media. It was confirmed that the dissolution in the hydrochloric acid solution is easily achieved by the plasma voloxidation and by the addition of oxygen peroxide into the hydrochloric acid solution.
NASA Astrophysics Data System (ADS)
Tessarolo, Francesco; Ferrari, Paolo; Silvia, Bortoluzzi; Motta, Antonella; Migliaresi, Claudio; Zennaro, Lucio; Rigo, Adelio; Guarrera, Giovanni Maria; Nollo, Giandomenico
2004-11-01
The increasing demand in interventional cardiology urges for reprocessing of single-use-labelled medical devices. To fulfil this aim, accurate and validated regeneration protocols are mandatory to guarantee sterility, functionality and safeness. The reprocessing protocol was realized by decontamination with chloro-donors, cleaning with enzymatic solutions and hydrogen peroxide gas plasma sterilization. Reprocessing effects on ablation and electrophysiology catheters were evaluated by assessing physical-chemical changes on surfaces and bulks, as a function of the reprocessing cycles number. Conventional optical microscopy and environmental scanning electron microscopy (ESEM) underlined the presence of micro-scratches on the polyurethane shaft surface. A clear correlation was found between surface damages and number of reprocessing cycles. Atomic force microscopy (AFM) confirmed the occurrence of physical-chemical etching of the polyurethane shaft caused by the hydrogen peroxide plasma sterilization, with increasing of nano-roughness at increasing number of the reprocessing cycles. UV-Vis spectra performed on the incubation solution of polymeric shaft sample, showed an absorbance increase at about 208 nm. This fact could be attributed to the water elution from the polymer of low molecular weight oligomers. The presence of hydrolysis products of the polymeric shaft after incubation demands both the characterization of the products released in the solution and the chemical characterization of the water exposed surface.
De Jongh, A; Ten Broeke, E; Renssen, M R
1999-01-01
This paper considers the current empirical status of Eye Movement Desensitization and Reprocessing (EMDR) as a treatment method for specific phobias, along with some conceptual and practical issues in relation to its use. Both uncontrolled and controlled studies on the application of EMDR with specific phobias demonstrate that EMDR can produce significant improvements within a limited number of sessions. With regard to the treatment of childhood spider phobia, EMDR has been found to be more effective than a placebo control condition, but less effective than exposure in vivo. The empirical support for EMDR with specific phobias is still meagre, therefore, one should remain cautious. However, given that there is insufficient research to validate any method for complex or trauma related phobias, that EMDR is a time-limited procedure, and that it can be used in cases for which an exposure in vivo approach is difficult to administer, the application of EMDR with specific phobias merits further clinical and research attention.
Computational Challenges in Processing the Q1-Q16 Kepler Data Set
NASA Astrophysics Data System (ADS)
Klaus, Todd C.; Henze, C.; Twicken, J. D.; Hall, J.; McCauliff, S. D.; Girouard, F.; Cote, M.; Morris, R. L.; Clarke, B.; Jenkins, J. M.; Caldwell, D.; Kepler Science Operations Center
2013-10-01
Since launch on March 6th, 2009, NASA’s Kepler Space Telescope has collected 48 months of data on over 195,000 targets. The raw data are rife with instrumental and astrophysical noise that must be removed in order to detect and model the transit-like signals present in the data. Calibrating the raw pixels, generating and correcting the flux light curves, and detecting and characterizing the signals require significant computational power. In addition, the algorithms that make up the Kepler Science Pipeline and their parameters are still undergoing changes (most of which increase the computational cost), creating the need to reprocess the entire data set on a regular basis. We discuss how we have ported all of the core elements of the pipeline to the Pleiades cluster at the NASA Advanced Supercomputing (NAS) Division, the needs driving the port, and the technical challenges we faced. In 2011 we ported the Transiting Planet Search (TPS) and Data Validation (DV) modules to Pleiades. These pipeline modules operate on the full data set and the computational complexity increases roughly by the square of the number of data points. At the time of the port it had become infeasible to run these modules on our local hardware, necessitating the move to Pleiades. In 2012 and 2013 we turned our attention to the front end of the pipeline; Pixel-level Calibration (CAL), Photometric Analysis (PA), and Pre-Search Data Conditioning (PDC). Porting these modules to Pleiades will allow us to reprocess the complete data set on a more frequent basis. The last time we reprocessed all data for the front end we only had 24 months of data. We estimate that the full 48-month data set would take over 200 days to complete on local hardware. When the port is complete we expect to reprocess this data set on Pleiades in about a month. The NASA Science Mission Directorate provided funding for the Kepler Mission.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... DEPARTMENT OF ENERGY Notice of Availability of Draft Waste Incidental to Reprocessing Evaluation...: Notice of availability. SUMMARY: The Department of Energy (DOE) announces the availability of a draft... Center in West Valley, New York, are waste incidental to reprocessing and thus are not high-level...
Sterilization and reprocessing of materials and medical devices--reusability.
Jayabalan, M
1995-07-01
Problems associated with reprocessing of disposable medical devices such as hemodialysers with resterilization for reuse and changes in material properties with resterilization of polymeric (PVC, polypropylene, polyester, polycarbonate) materials intended for development of disposable devices are reviewed. Reprocessing of hospital supplies, polystyrene microtiter plate and angiographic catheter for reuse is also discussed.
[Destruction of microsurgical devices by sterilisation].
Berto, Raphaela; Strutz, Jürgen
2017-11-01
Hospital facilities issue numerous risk announcements on corrosion, deformation or premature wearout of medical devices every year. As there is yet little data on the impact of reprocessing on the quality and durability of microsurgical instruments, this paper aims at evaluating the effects of the reprocessing on microsurgical instruments. Material and Methods 22 brand new microsurgical instruments for stapes surgery were being reprocessed 30 times without being used for surgery or other purposes in the interim time. After each reprocessing the instruments were examined macroscopicly and microscopicly. The results were portrayed in a photo documentation and analysed on that basis. Results Almost all devices showed mechanical damage caused by the reprocessing procedure. The increasing deterioration was often associated with missing protective caps. Furthermore contaminations and stains were apparent in several cases. Conclusions The findings illustrate that careful handling of delicate surgical devices during reprocessing is vital. They also highlight problems of protective caps. As an alternative going forward it should be considered to store microsurgical instruments statically in special racks. Georg Thieme Verlag KG Stuttgart · New York.
ETR ELECTRICAL BUILDING, TRA648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. ...
ETR ELECTRICAL BUILDING, TRA-648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. METAL ROOF AND PUMICE BLOCK WALLS. CAMERA FACING SOUTHWEST. INL NEGATIVE NO. 56-3708. R.G. Larsen, Photographer, 11/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR ELECTRICAL BUILDING, TRA648. FLOOR PLANS FOR FIRST FLOOR AND ...
ETR ELECTRICAL BUILDING, TRA-648. FLOOR PLANS FOR FIRST FLOOR AND BASEMENT. SECTIONS. KAISER ETR-5528-MTR-648-A-2, 12/1955. INL INDEX NO. 532-0648-00-486-101402, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. Outdoor turntable. Workings and design exposed during demolition. View ...
A&M. Outdoor turntable. Workings and design exposed during demolition. View between two of the four rails of the track. Note motor and electrical conduit. Date: February 3, 2003. INEEL negative no. HD-37-1-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. CAMERA FACING SOUTH INTO ETR ELECTRICAL BUILDING (TRA-648). INL NEGATIVE NO. HD46-20-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR ELECTRICAL BUILDING, TRA648. ELEVATIONS AND DETAILS. ROOF PLAN. DOOR ...
ETR ELECTRICAL BUILDING, TRA-648. ELEVATIONS AND DETAILS. ROOF PLAN. DOOR SCHEDULE. KAISER ETR-5528-MTR-648-A-3, 1/1956. INL INDEX NO. 532-0648-00-486-101403, REV. 5. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
4. CONSTRUCTION PROGRESS VIEW OF EQUIPMENT IN FRONT PART OF ...
4. CONSTRUCTION PROGRESS VIEW OF EQUIPMENT IN FRONT PART OF CONTROL BUNKER (TRANSFORMER, HYDRAULIC TANK, PUMP, MOTOR). SHOWS UNLINED CORRUGATED METAL WALL. CAMERA FACING EAST. INEL PHOTO NUMBER 65-5433, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
LPT. Shield test control building (TAN645), north facade. Camera facing ...
LPT. Shield test control building (TAN-645), north facade. Camera facing south. Obsolete sign dating from post-1970 program says "Energy and Systems Technology Experimental Facility, INEL." INEEL negative no. HD-40-5-4 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS ...
ETR BUILDING, TRA-642, INTERIOR. BASEMENT. ROLLUP DOOR TO CUBICLE POSTS CAUTION SIGNS BECAUSE OF SODIUM HAZARD WITHIN. INL NEGATIVE NO. HD24-3-1. Mike Crane, Photographer, 11/2000 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
12. VIEW OF (PRESUMED) OUTHOUSE SHED. DOOR HAS AN AIR ...
12. VIEW OF (PRESUMED) OUTHOUSE SHED. DOOR HAS AN AIR FORCE INSIGNIA EMBLEM AFFIXED, 'AIR FORCE WEAPONS LABORATORY.' OTHER SIGN ON DOOR SAYS, 'BSD LIASON OFFICE.' INEL PHOTO NUMBER 65-6173, TAKEN NOVEMBER 10, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
IET area plot and utilities plan. Includes drainage. Ralph M. ...
IET area plot and utilities plan. Includes drainage. Ralph M. Parsons 902-4-ANP-U-310. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL code no. 035-0100-00-693-106898 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LOFT. Interior view of entry (TAN624) rollup door. Camera is ...
LOFT. Interior view of entry (TAN-624) rollup door. Camera is inside entry building facing south. Rollup door was a modification of the original ANP door arrangement. Date: March 2004. INEEL negative no. HD-39-5-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
MTR WING, TRA604, INTERIOR. BASEMENT. WEST CORRIDOR. CAMERA FACES NORTH. ...
MTR WING, TRA-604, INTERIOR. BASEMENT. WEST CORRIDOR. CAMERA FACES NORTH. HVAC AREA IS AT RIGHT OF CORRIDOR. INL NEGATIVE NO. HD46-13-3. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR HEAT EXCHANGER BUILDING, TRA644. DETAIL OF SOUTH SIDE BUILDING ...
ETR HEAT EXCHANGER BUILDING, TRA-644. DETAIL OF SOUTH SIDE BUILDING INSET. DEMINERALIZER WING AT RIGHT. CAMERA FACING NORTH. INL NEGATIVE NO. HD46-36-2. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
123. ARAI Substation (ARA726) plan, elevation, security fence details, and ...
123. ARA-I Substation (ARA-726) plan, elevation, security fence details, and sections. Norman Engineering Company 961-area/SF-726-E-1. Date: January 1959. Ineel index code no. 068-0726-10-613-102778. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, ...
29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, CABLE CHASE, SHIELDING TANK AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-1. INEL INDEX CODE NUMBER: 075 0701 851 151970. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
31. SECTIONS AND DETAILS OF ARVFS FACILITY, INCLUDING RADIATION HAZARD ...
31. SECTIONS AND DETAILS OF ARVFS FACILITY, INCLUDING RADIATION HAZARD SIGN, WOOD RETAINING WALL, TANK COVER, AND DRAIN BOX. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-3. INEL INDEX CODE NUMBER: 075 0701 851 151972. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
144. ARAIII Control building (ARA607) Foundation plan. Aerojetgeneral 880area/GCRE607S1. Date: ...
144. ARA-III Control building (ARA-607) Foundation plan. Aerojet-general 880-area/GCRE-607-S-1. Date: February 1958. Ineel index code no. 063-0607-60-013-102568. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
32. ISOMETRIC VIEW OF PIPING PLAN, SHOWING PATH OF CONDUIT ...
32. ISOMETRIC VIEW OF PIPING PLAN, SHOWING PATH OF CONDUIT FROM CONTROL BUNKER TO SHIELDING TANK. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-P-1. INEL INDEX CODE NUMBER: 075 0701 60 851 151977. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
PBF Reactor Building (PER620). Camera in first basement, facing south ...
PBF Reactor Building (PER-620). Camera in first basement, facing south and upward toward main floor. Cable trays being erected. Photographer: Kirsh. Date: May 20, 1969. INEEL negative no. 69-3110 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) interior, second basement level. Coolant and tank piping. ...
PBF (PER-620) interior, second basement level. Coolant and tank piping. Mark on vertical pipe says, "H.P. Demin. Water." (High pressure demineralized water.) Date: March 2004. INEEL negative no. HD-41-4-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) interior, basement level. Concrete wall shows outline of ...
PBF (PER-620) interior, basement level. Concrete wall shows outline of reactor basin. Sign says, "Flashing Light - Reactor On - Evacuate Area." Date: May 2004. INEEL negative no. HD-41-5-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) south facade. Camera facing north. Note pedestrian bridge ...
PBF (PER-620) south facade. Camera facing north. Note pedestrian bridge crossing over conduit. Central high bay contains reactor room and canal. Date: March 2004. INEEL negative no. HD-41-2-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI Terminal Building (PER604) with view into interior. Storage tanks ...
SPERT-I Terminal Building (PER-604) with view into interior. Storage tanks and equipment in view. Camera facing west. Photographer: R.G. Larsen. Date: May 20, 1955. INEEL negative no. 55-1291 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
LPT. Low power test (TAN641) interior of mechanical equipment room. ...
LPT. Low power test (TAN-641) interior of mechanical equipment room. Air compressors in left foreground. Evaporate condenser in right background. Construction 93% complete. Photographer: Jack L. Anderson. Date: October 23, 1957. INEEL negative no. 57-5340 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
87. ARAIII. GCRE reactor building (ARA608) Mechanical equipment room. Utility ...
87. ARA-III. GCRE reactor building (ARA-608) Mechanical equipment room. Utility air receiver, dryer, and compressor sit on their foundations prior to grouting. December 22, 1958. Ineel photo no. 58-6429. Photographer: Ken Mansfield. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
157. ARAIII Reactor building (ARA608) Main gas loop mechanical flow ...
157. ARA-III Reactor building (ARA-608) Main gas loop mechanical flow sheet. This drawing was selected as a typical example of mechanical arrangements within reactor building. Aerojet-general 880-area/GCRE-0608-50-013-102634. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
MTR STACK, TRA710, CONTEXTUAL VIEW, CAMERA FACING SOUTH. PERIMETER SECURITY ...
MTR STACK, TRA-710, CONTEXTUAL VIEW, CAMERA FACING SOUTH. PERIMETER SECURITY FENCE AND SECURITY LIGHTING IN VIEW AT LEFT. INL NEGATIVE NO. HD52-1-1. Mike Crane, Photographer, 5/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
REACTIVITY MEASUREMENT FACILITY, UNDER CONSTRUCTION OVER MTR CANAL IN BASEMENT ...
REACTIVITY MEASUREMENT FACILITY, UNDER CONSTRUCTION OVER MTR CANAL IN BASEMENT OF MTR BUILDING, TRA-603. WOOD PLANKS REST ON CANAL WALL OBSERVABLE IN FOREGROUND. INL NEGATIVE NO. 11745. Unknown Photographer, 8/20/1954 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
23. INTERIOR OF TAN 629 HANGAR, TAKEN FROM LOW ROOF, ...
23. INTERIOR OF TAN 629 HANGAR, TAKEN FROM LOW ROOF, FACING NORTHEAST. SHOWS GROUND LEVEL USE OF FLOOR SPACE FOR TEMPORARY STORAGE OF CRATES. MOISTURE ON SURFACE IS FROM LEAKY HANGAR ROOF. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
65. ARAII. Interior view of SL1 reactor building control piping ...
65. ARA-II. Interior view of SL-1 reactor building control piping for water purification system. On operating floor of building. March 21, 1958. Ineel photo no. 58-1360. Photographer: Jack L. Anderson. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Control Building (PER619). Interior of control room shows control ...
PBF Control Building (PER-619). Interior of control room shows control console from direction facing visitors room and its observation window. Camera facing northeast. Date: May 2004. INEEL negative no. HD-41-7-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
MTR WING, TRA604. PRECAST CONCRETE PANELS AND DIMENSIONS FOR PANELS ...
MTR WING, TRA-604. PRECAST CONCRETE PANELS AND DIMENSIONS FOR PANELS K THROUGH Q. BLAW-KNOX 3150-804-21, SHEET #2, 11/1950. INL INDEX NO. 531-0604-62-098-100645, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
154. ARAIII Reactor building (ARA608) Foundation sections and details. Shows ...
154. ARA-III Reactor building (ARA-608) Foundation sections and details. Shows profiles of pits. Aerojet-general 888-area/GCRE-608-S-2. Date: February 1958. Ineel index code no. 062-0608-60-013-102654. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
153. ARAIII Reactor building (ARA608) Foundation plan. Aerojetgeneral 880area/GCRE608S1. Date: ...
153. ARA-III Reactor building (ARA-608) Foundation plan. Aerojet-general 880-area/GCRE-608-S-1. Date: February 1958. Ineel index code no. 063-0608-60-013-102653. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
IET. Control and equipment building (TAN620) sections. Depth and profile ...
IET. Control and equipment building (TAN-620) sections. Depth and profile of earthen shield tunnels. Ralph M. Parsons 902-4-ANP-620-A-321. Date: February 1954. INEEL index code no. 035-0620-00-693-106906 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
152. ARAIII Reactor building (ARA608) Details of heater and piping ...
152. ARA-III Reactor building (ARA-608) Details of heater and piping pits, including instrumentation plan. Aerojet-general 880-area/GCRE-608-T-18. Date: November 1958. Ineel index code no. 063-0608-25-013-102677. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
149. ARAIII Reactor building (ARA608) Exterior elevations, showing north, south, ...
149. ARA-III Reactor building (ARA-608) Exterior elevations, showing north, south, east, and west. Aerojet-general 880-area/GCRE-608-A-6. Date: February 1958. Ineel index code no. 063-0608-00-013-102615. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
LOFT. Containment and service building (TAN650). Room number schedule, sheet ...
LOFT. Containment and service building (TAN-650). Room number schedule, sheet 2 of 2. Kaiser engineers 6413-11-STEP/LOFT-650-A-XX. Date: October 1969. INEEL index code no. 036-650-00-486-122228 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
151. ARAIII Reactor building (ARA608) Details of reactor pit and ...
151. ARA-III Reactor building (ARA-608) Details of reactor pit and instrument plan. Aerojet-general 880-area/GCRE-608-T-19. Date: November 1958. Ineel index code no. 063-0608-25-013-102678. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
NORTH BASEMENT WALL. IBEAM COLUMNS HAVE BEEN ENCASED IN CONCRETE. ...
NORTH BASEMENT WALL. I-BEAM COLUMNS HAVE BEEN ENCASED IN CONCRETE. STEEL BEAMS LAY ACROSS FIRST FLOOR AWAITING CONCRETE POUR. CAMERA LOOKS SOUTHWEST. INL NEGATIVE NO. 735. Unknown Photographer, 10/6/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
35. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING EAST ...
35. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING EAST AND WEST ELEVATIONS AND OTHER DETAILS. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-629-A-4. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
PBF Cooling Tower Auxiliary Building (PER624) interior. Camera facing north. ...
PBF Cooling Tower Auxiliary Building (PER-624) interior. Camera facing north. Deluge valves and automatic fire protection piping for Cooling Tower. Photographer: Holmes. Date: May 20, 1970. INEEL negative no. 70-2323 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
1. VIEW OF ARVFS BUNKER TAKEN FROM GROUND ELEVATION. CAMERA ...
1. VIEW OF ARVFS BUNKER TAKEN FROM GROUND ELEVATION. CAMERA FACING NORTH. VIEW SHOWS PROFILE OF BUNKER IN RELATION TO NATURAL GROUND ELEVATION. TOP OF BUNKER HAS APPROXIMATELY THREE FEET OF EARTH COVER. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
PBF Reactor Building (PER620) Cubicle 13. Plan, section, details. Note ...
PBF Reactor Building (PER-620) Cubicle 13. Plan, section, details. Note "quality assurance" code at bottom of drawing. Aerojet Nuclear Company. Date: May 1976. INEEL index no. 761-0620-00-400-195279 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
A&M. Hot liquid waste treatment building (TAN616). Camera facing northeast. ...
A&M. Hot liquid waste treatment building (TAN-616). Camera facing northeast. South wall with oblique views of west sides of structure. Photographer: Ron Paarmann. Date: September 22, 1997. INEEL negative no. HD-20-1-2 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Hot liquid waste treatment building (TAN616). Camera facing north. ...
A&M. Hot liquid waste treatment building (TAN-616). Camera facing north. Detail of personnel entrance door, stoop, and stairway. Photographer: Ron Paarmann. Date: September 22, 1997. INEEL negative no. HD-20-2-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. ONE OF THREE EVAPORATORS BEFORE IT ...
PROCESS WATER BUILDING, TRA-605. ONE OF THREE EVAPORATORS BEFORE IT IS INSTALLED IN UPPER LEVEL OF EAST HALF OF BUILDING. INL NEGATIVE NO. 1533. Unknown Photographer, 3/1/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PBF Cubicle 13. Shield wall details illustrate shielding technique of ...
PBF Cubicle 13. Shield wall details illustrate shielding technique of stepped penetrations and brick layout scheme for valve stem extension sleeve. Aerojet Nuclear Company. Date: May 1976. INEEL index no. 761-0620-00-400-195280 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ADVANCED REACTIVITY MEASUREMENT FACILITY, TRA660, INTERIOR. REACTOR INSIDE TANK. METAL ...
ADVANCED REACTIVITY MEASUREMENT FACILITY, TRA-660, INTERIOR. REACTOR INSIDE TANK. METAL WORK PLATFORM ABOVE. THE REACTOR WAS IN A SMALL WATER-FILLED POOL. INL NEGATIVE NO. 66-6373. Unknown Photographer, ca. 1966 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PBF (PER620) interior, first basement. Detail of valves and other ...
PBF (PER-620) interior, first basement. Detail of valves and other penetrations along wall. Bricks are made of high density shielding materials. Date: March 2004. INEEL negative no. HD-41-4-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI Electric Control Building (PER608). Plan, elevations, and details. Gibbs ...
SPERT-I Electric Control Building (PER-608). Plan, elevations, and details. Gibbs and Hill, Inc. 1087-PER-608-S5. Date: August 1956. INEEL index no. 760-0608-00-312-108328 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
A&M. TAN607. Southern sections added in expansion project of 1957. ...
A&M. TAN-607. Southern sections added in expansion project of 1957. Camera facing northwest. Concrete decontamination section on left end. Photographer: Jack L. Anderson. Date: October 23, 1957. INEEL negative no. 57-5337 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ETR, TRA642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, ...
ETR, TRA-642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, CRANE WORKING AREAS. PHILLIPS PETROLEUM COMPANY ETR-D-1584, 5/1959. INL INDEX NO. 532-0642-00-706-020323, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
TIGA Tide Gauge Data Reprocessing at GFZ
NASA Astrophysics Data System (ADS)
Deng, Zhiguo; Schöne, Tilo; Gendt, Gerd
2014-05-01
To analyse the tide gauge measurements for the purpose of global long-term sea level change research a well-defined absolute reference frame is required by oceanographic community. To create such frame the data from a global GNSS network located at or near tide gauges are processed. For analyzing the GNSS data on a preferably continuous basis the International GNSS Service (IGS) Tide Gauge Benchmark Monitoring Working Group (TIGA-WG) is responsible. As one of the TIGA Analysis Centers the German Research Centre for Geosciences (GFZ) is contributing to the IGS TIGA Reprocessing Campaign. The solutions of the TIGA Reprocessing Campaign will also contribute to 2nd IGS Data Reprocessing Campaign with GFZ IGS reprocessing solution. After the first IGS reprocessing finished in 2010 some improvements were implemented into the latest GFZ software version EPOS.P8: reference frame IGb08 based on ITRF2008, antenna calibration igs08.atx, geopotential model (EGM2008), higher-order ionospheric effects, new a priori meteorological model (GPT2), VMF mapping function, and other minor improvements. GPS data of the globally distributed tracking network of 794 stations for the time span from 1994 until end of 2012 are used for the TIGA reprocessing. To handle such large network a new processing strategy is developed and described in detail. In the TIGA reprocessing the GPS@TIGA data are processed in precise point positioning (PPP) mode to clean data using the IGS reprocessing orbit and clock products. To validate the quality of the PPP coordinate results the rates of 80 GPS@TIGA station vertical movement are estimated from the PPP results using Maximum Likelihood Estimation (MLE) method. The rates are compared with the solution of University of LaRochelle Consortium (ULR) (named ULR5). 56 of the 80 stations have a difference of the vertical velocities below 1 mm/yr. The error bars of PPP rates are significant larger than those of ULR5, which indicates large time correlated noise in the PPP solutions.
NASA Astrophysics Data System (ADS)
Huang, J.; Weng, F.; Sun, N.
2017-12-01
As the inputs to satellite Environmental Data Records (EDR) that provide continuous monitoring of Earth System changes from space, Sensor Data Records (SDR) need to meet very high standards of accuracy. SDR reprocessing, aiming for accurately accounting sensor degradation and calibration issues, is therefore very important in satellite remote sensing. Previous studies on heritage Terra MODIS in NASA Earth Observation System (EOS) indicated that SDR degradation over time, if not correctly calibrated and reprocessed, can result in false trending in several key satellite EDR observations, such as aerosol optical depth (AOD) and vegetation index (VI). Yet the sensitivity of these EDRs to the changes in the reprocessed SDRs is still not comprehensively understood or quantified. As part of the Suomi NPP SDR long term monitoring efforts, the current ongoing SDR reprocessing at NOAA NESDIS STAR provides a unique test bed for quantifying the changes of EDRs to the reprocessed SDRs, and thus improves our understanding of the potential impacts of the SDR reprocessing on our capability of critical Earth observations. For the sensitivity investigation, we selected the VIIRS aerosol algorithm, which EDR algorithm uses most of the visible to near infrared (VIS-NIR) SDR bands. Several aerosol hotspot regions over the globe are selected for conducting AOD trending analysis under several prescribed SDR reprocessing scenarios, and the changes in the spatial and temporal characterizations of AOD are linked to the changes in SDR for exploration of any potential systematic relations. Preliminary results indicated that although changes varies by regions and seasons, some EDRs can be sensitive to even slight SDR changes in certain VIS-NIR bands. The study sheds important lights on how we can use the SDR-EDR relation as an additional approach to facilitate the SDR reprocessing evaluation. Details of the finding will be reported at the presentation.
TRMM Data Improvement as Part of the GPM Data Processing
NASA Technical Reports Server (NTRS)
Stocker, Erich F.; Ji, Y.; Kwiatkowski, J.; Kelley, O.; Stout, J.; Woltz, L.
2016-01-01
NASA has a long standing commitment to the improvement of its mission datasets. Indeed, data reprocessing is always built into the plans, schedule and budget for the mission data processing system. However, in addition to these ongoing mission reprocessing, NASA also supports a final reprocessing of all the data for a mission upon its completion (known as Phase F). TRMM Phase F started with the end of the TRMM mission in June of 2015. This last reprocessing has two overall goals: improvement of the TRMM mission data products; incorporation of the 17+ years of TRMM data into the ongoing NASA/JAXA GPM data processing. The first goal guarantees that the latest algorithms used for precipitation retrievals will also be used in reprocessing the TRMM data. The second goal ensures that as GPM algorithms are improved, the entire TRMM data will always be reprocessed with each GPM reprocessing. In essence TRMM becomes another of the GPM constellation satellites. This paper will concentrate on presenting the improvements to TMI level 1 data including calibration, geolocation, and emissive antenna corrections. It will describe the format changes that will occur how the TMI level 1C product will be intercalibrated using GMI as the reference calibration. It will also provide an overview of changes in the precipitation radar products as well as the combined TMIPR product.
Kraft, Marc
2008-09-03
Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.
Kraft, Marc
2008-01-01
Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority. PMID:20204095
CUTS FOR MTR EXCAVATION ILLUSTRATE SEDIMENTARY MANTLE OF SOIL AND ...
CUTS FOR MTR EXCAVATION ILLUSTRATE SEDIMENTARY MANTLE OF SOIL AND GRAVEL OVERLAYING LAVA ROCK FIFTY FEET BELOW. SAGEBRUSH HAS BEEN SCOURED FROM REST OF SITE. CAMERA PROBABLY FACES SOUTHWEST. INL NEGATIVE NO. 67. Unknown Photographer, 6/4/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605, INTERIOR. FIRST FLOOR. ELECTRICAL EQUIPMENT IN ...
PROCESS WATER BUILDING, TRA-605, INTERIOR. FIRST FLOOR. ELECTRICAL EQUIPMENT IN LEFT HALF OF VIEW. CAMERA IS IN NORTHWEST CORNER FACING SOUTHEAST. INL NEGATIVE NO. HD46-27-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG ...
ETR BUILDING, TRA-642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG SOUTH PERIMETER WALL (COMMON TO ELECTRICAL BUILDING, TRA-648). CAMERA FACES WEST. INL NEGATIVE NO. HD46-16-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. ELEVATIONS. METAL SIDING. OFFICE BUILDING (TRA647) AND ELECTRICAL ...
ETR, TRA-642. ELEVATIONS. METAL SIDING. OFFICE BUILDING (TRA-647) AND ELECTRICAL BUILDING (TRA-648) ATTACHED. KAISER ETR-5528-MTR-642-A-11, 11/1955. INL INDEX NO. 532-0642-00-486-100919, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. WALL SECTION DETAILS. METAL SIDING JOINS TO ELECTRICAL ...
ETR, TRA-642. WALL SECTION DETAILS. METAL SIDING JOINS TO ELECTRICAL BUILDING, OFFICE BUILDING, AND ROOF. KAISER ETR-5528-MTR-A-13, 11/1955. INL INDEX NO. 532-0642-00-486-100920, REV. 4. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
156. ARAIII Reactor building (ARA608) Electrical and control details of ...
156. ARA-III Reactor building (ARA-608) Electrical and control details of mobile work bridge over reactor and pipiing pits. Aerojet-general 880-area/GCRE-608-E-6. Date: November 1958. Ineel index code no. 063-0608-10-013-102621. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
ETR, TRA642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTORGENERATOR ...
ETR, TRA-642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTOR-GENERATOR SETS AND OTHER ELECTRICAL EQUIPMENT. PHILLIPS PETROLEUM COMPANY ETR-D-1781, 7/1960. INL INDEX NO. 532-0642-00-706-020384, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SPERTI Terminal Building (PER604). Oblique view of front entry and ...
SPERT-I Terminal Building (PER-604). Oblique view of front entry and one side. Electrical transformers at right of building. Note "Butler" logo. Photographer: R.G. Larsen. Date: June 22, 1955. INEEL negative no. 55-1700 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
IET control building (TAN620). interior service area. equipment on concrete ...
IET control building (TAN-620). interior service area. equipment on concrete pads. liquid pump and valves on right. control panel at center of view, blower at left. piping for vent and sanitary sewer. INEEL negative no. HD-21-3-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Shield test facility test building interior (TAN646). Camera facing ...
LPT. Shield test facility test building interior (TAN-646). Camera facing south. Distant pool contained EBOR reactor; near pool was intended for fuel rod storage. Other post-1970 activity equipment remains in pool. INEEL negative no. HD-40-9-4 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Shield test facility test building interior (TAN646). Camera points ...
LPT. Shield test facility test building interior (TAN-646). Camera points down into interior of north pool. Equipment on wall is electronical bus used for post-1970 experiment. Personnel ladder at right. INEEL negative no. HD-40-9-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
SAFETY AND SECURITY BUILDING, TRA614. FLOOR, ROOF, AND FOUNDATION PLANS. ...
SAFETY AND SECURITY BUILDING, TRA-614. FLOOR, ROOF, AND FOUNDATION PLANS. ROOM FUNCTIONS. DOOR AND ROOM FINISH SCHEDULE. BLAW-KNOX 3150-814-1, 3/1950. INL INDEX NO. 531-0614-00-098-100702, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SOUTH WING, MTR661. INTERIOR DETAIL INSIDE LAB ROOM 131. CAMERA ...
SOUTH WING, MTR-661. INTERIOR DETAIL INSIDE LAB ROOM 131. CAMERA FACING NORTHEAST. NOTE CONCRETE BLOCK WALLS. SAFETY SHOWER AND EYE WASHER AT REAR WALL. INL NEGATIVE NO. HD46-7-2. Mike Crane, Photographer, 2/2005. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PBF Cooling Tower. View of stairway to fan deck. Vents ...
PBF Cooling Tower. View of stairway to fan deck. Vents are made of redwood. Camera facing southwest toward north side of Cooling Tower. Siding is corrugated asbestos concrete. Photographer: Kirsh. Date: June 6, 1969. INEEL negative no. 69-3463 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
32. SECTIONS AA, BB, CC, DD, AND EE WASTE CALCINATION ...
32. SECTIONS A-A, B-B, C-C, D-D, AND E-E WASTE CALCINATION FACILITY SHOWING RELATIONSHIPS OF DIFFERENT FLOOR LEVELS TO ONE ANOTHER. INEEL DRAWING NUMBER 200-0633-00-287-106353. FLUOR NUMBER 5775-CPP-633-A-3. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
36. ARCHITECTURAL AND STRUCTURAL DETAILS OF ELEVATOR HOUSING, NaK HEATER ...
36. ARCHITECTURAL AND STRUCTURAL DETAILS OF ELEVATOR HOUSING, NaK HEATER STACK ROOF FLASHING, HOOD ELEVATION DETAIL. INCLUDES PARTIAL 'BILL OF MATERIAL.' INEEL DRAWING NUMBER 200-0633-00-287-106361. FLUOR NUMBER 5775-CPP-633-A-11. - Idaho National Engineering Laboratory, Old Waste Calcining Facility, Scoville, Butte County, ID
LPT. EBOR (TAN646). Floor plan for new helium management wing. ...
LPT. EBOR (TAN-646). Floor plan for new helium management wing. Detail of sample vault and basement switch room. Kaiser engineers EBOR/GA-646-A-101. Date: May 1963. INEEL index code no. 037-0646-00-486-119115 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LOFT. Interior, control room in control building (TAN630). Camera facing ...
LOFT. Interior, control room in control building (TAN-630). Camera facing north. Sign says "This control console is partially active. Do not operate any switch handle without authorization." Date: May 2004. INEEL negative no. HD-39-14-3 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Service Building (TAN603). Floor plan. Names of functional areas. ...
ADM. Service Building (TAN-603). Floor plan. Names of functional areas. Ralph M. Parsons 902-2-ANY-603-A 43. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 033-0603-00-693-106718 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
FET. Control and equipment building (TAN630). Sections. Ralph M. Parsons ...
FET. Control and equipment building (TAN-630). Sections. Ralph M. Parsons 1229-2 ANP/GE-5-630-A-4. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0630-00-693-107083 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Warehouse (TAN604). Elevations and sections. Ralph M. Parsons 9022ANP604A ...
ADM. Warehouse (TAN-604). Elevations and sections. Ralph M. Parsons 902-2-ANP-604-A 56. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0604-00-693-106728 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Change House (TAN606). Elevations and floor plan. Room Names. ...
ADM. Change House (TAN-606). Elevations and floor plan. Room Names. Ralph M. Parsons 902-2-ANP-606-A 65. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0606-00-693-106733 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
FET. Exhaust duct and stack. Plan, elevation, foundation, details. Ralph ...
FET. Exhaust duct and stack. Plan, elevation, foundation, details. Ralph M. Parsons 1480-10 ANP/GE-5-716-S-3. Date: February 1959. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0716-00-693-107474 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
FET. Chlorination building, TAN637. Elevations, section. Ralph M. Parsons 12292 ...
FET. Chlorination building, TAN-637. Elevations, section. Ralph M. Parsons 1229-2 ANP/GE-5-637-A-S-H&V-1. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0637-00-693-107148 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Warehouse (TAN604) Floor plan. General warehouse and chemical storage. ...
ADM. Warehouse (TAN-604) Floor plan. General warehouse and chemical storage. Ralph M. Parsons 902-2-ANP-604-A 55. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0604-00-693-106727 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Water System Pump House (TAN610). Elevations, plan, and sections. ...
ADM. Water System Pump House (TAN-610). Elevations, plan, and sections. Ralph M. Parsons 902-2-ANP-610-A 74. Date: February 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0610-00-693-106739 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET. Control and equipment building (TAN620). Blast roof details. Ralph ...
IET. Control and equipment building (TAN-620). Blast roof details. Ralph M. Parsons 902-4-ANP-620-A-323. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-620-00-693-106908 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET. Control and equipment building (TAN620). Details and room finish ...
IET. Control and equipment building (TAN-620). Details and room finish schedule. Ralph M. Parsons 902-4-ANP-620-A 322. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0629-00-693-106907 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Administration Building (TAN602). Early room layout, door and room ...
ADM. Administration Building (TAN-602). Early room layout, door and room schedules. Ralph M. Parsons 902-2-ANP-602-A 31. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 033-0602-00-693-106710 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Shield test facility (TAN646) exterior, as modified for EBOR. ...
LPT. Shield test facility (TAN-646) exterior, as modified for EBOR. Camera facing northeast. Heat exchange fans, helium storage tanks, and completed EBOR perimeter road. Photographer: Page Comisky. Date: ca. August 20, 1965. INEEL negative no. 65-4328 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
36. DETAILS AND SECTIONS OF SHIELDING TANK, FUEL ELEMENT SUPPORT ...
36. DETAILS AND SECTIONS OF SHIELDING TANK, FUEL ELEMENT SUPPORT FRAME AND SUPPORT PLATFORM, AND SAFETY MECHANISM ASSEMBLY (SPRING-LOADED HINGE). F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-1. INEL INDEX CODE NUMBER: 075 0701 60 851 151975. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
141. ARAIII Equipment location plan. Includes list of equipment and ...
141. ARA-III Equipment location plan. Includes list of equipment and location in reactor, control, and other buildings. Aerojet-general 880-area/GCRE-101-U-1. Date: February 1958. Ineel index code no. 063-0101-65-013-192508. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
132. ARAII Administration building (ARA613) elevations of north, south, east, ...
132. ARA-II Administration building (ARA-613) elevations of north, south, east, and west sides. F. C. Torkelson Company 842-area/SL-1-613-A-2. Date: October 1959. Ineel index no. 070-0613-00-851-150054. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
35. DETAILS AND SECTIONS OF FUEL ELEMENT SUPPORT PLATFORM, FUEL ...
35. DETAILS AND SECTIONS OF FUEL ELEMENT SUPPORT PLATFORM, FUEL ELEMENT HOLDER, TRIP MECHANISM COVER, AND OTHER DETAILS. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-S-3. INEL INDEX CODE NUMBER: 075 0701 60 851 151977. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
119. ARAI Shop and maintenance (ARA627) building sections and details ...
119. ARA-I Shop and maintenance (ARA-627) building sections and details of interior mesh partitions. Norman Engineering Company 961-area/SF-627-A-3. Date: January 1959. Ineel index code no. 068-0627-00-613-102761. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
117. ARAI Shop and maintenance (ARA627) building roof and floor ...
117. ARA-I Shop and maintenance (ARA-627) building roof and floor plan. Includes room finish and equipment schedule. Norman Engineering Company 961-area/SF-627-A-1. Date: January 1959. Ineel index code no. 068-0627-00-613-102759. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
41. INDEX OF ALL TAN 629 HANGAR DRAWINGS IN THE ...
41. INDEX OF ALL TAN 629 HANGAR DRAWINGS IN THE RALPH M. PARSONS SERIES OF DRAWINGS OF THE FLIGHT ENGINE TEST FACILITY. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-100. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
140. ARAIII Grading and drainage plan showing plot plan, including ...
140. ARA-III Grading and drainage plan showing plot plan, including berms around waste storage tank and fuel oil storage tank. Aerojet-general 880-area-GCRE-101-1. Date: February 1958. Ineel index code no. 063-0101-00-013-102507. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF ...
30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF SOUTH SIDE OF FACILITY, INCLUDING BUNKER, CABLE CHASE, SHIELDING TANK, AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-2. INEL INDEX CODE NUMBER: 075 0701 851 151971. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
112. ARAI Hot cell (ARA626) Building roof plan and details ...
112. ARA-I Hot cell (ARA-626) Building roof plan and details of roof ventilating equipment and parapet. Norman Engineering Company: 961-area/SF-626-A-2. Date: January 1959. Ineel index code no. 068-0626-00-613-102722. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS ...
28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS LINCOLN BOULEVARD, BIG LOST RIVER, AND NAVAL REACTORS FACILITY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-101-2. DATED OCTOBER 12, 1965. INEL INDEX CODE NUMBER: 075 0101 851 151969. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
A&M. TAN607. Detail of control gallery for special services cubicle ...
A&M. TAN-607. Detail of control gallery for special services cubicle (hot cell) at "100 percent complete." Cover has been removed from cable channel at middle window. Date: January 24, 1995. INEEL negative No. 55-0140 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET. Control room in control building (TAN620). Terminal panels for ...
IET. Control room in control building (TAN-620). Terminal panels for instrumentation wiring. Note alarm horn and emergency light at right edge of view. Cable reel comes from Collier, Pawtucket, RI. Date: February 1955. INEEL negative no. 55-362 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
7. CONSTRUCTION PROGRESS VIEW (INTERIOR) OF CONTROL ROOM PANEL INSIDE ...
7. CONSTRUCTION PROGRESS VIEW (INTERIOR) OF CONTROL ROOM PANEL INSIDE BUNKER. SHOWS OPENING TO CABLE CHASE, FOUR PULLEY DEVICES, POWER OUTLET, CONDUIT, AND EAST END WALL OF BUNKER. INEL PHOTO NUMBER 65-5441, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
SPERTI Terminal Building (PER604). Concrete foundation is at grade. Steel ...
SPERT-I Terminal Building (PER-604). Concrete foundation is at grade. Steel frame has been erected, and some siding has been affixed. Photographer: R.G. Larsen. Date: April 22, 1955. INEEL negative no. 55-1003 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF. Oblique and contextual view of PBF Cooling Tower, PER720. ...
PBF. Oblique and contextual view of PBF Cooling Tower, PER-720. Camera facing northeast. Auxiliary Building (PER-624) abuts Cooling Tower. Demolition equipment has arrived. Date: August 2003. INEEL negative no. HD-35-11-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Camera in second basement near subpile ...
PBF Reactor Building (PER-620). Camera in second basement near sub-pile room (directly below reactor vessel). Door and penetrations lead to sub-pile room. Date: August 15, 1969. Photographer: Larry Page. INEEL negative no. 69-4310 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Cooling Tower contextual view. Camera facing southwest. West wing ...
PBF Cooling Tower contextual view. Camera facing southwest. West wing and north facade (rear) of Reactor Building (PER-620) is at left; Cooling Tower to right. Photographer: Kirsh. Date: November 2, 1970. INEEL negative no. 70-4913 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) interior. Detail view of door in north wall ...
PBF (PER-620) interior. Detail view of door in north wall of reactor bay. Camera facing north. Note tonnage weighting of hatch covers in floor. Date: May 2004. INEEL negative no. HD-41-8-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF (PER620) interior. Detail view of actuator platform and control ...
PBF (PER-620) interior. Detail view of actuator platform and control rod mechanism. Camera facing easterly from floor level. Reactor pool at lower left of view. Date: March 2004. INEEL negative no. HD-41-3-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Camera faces southeast. Concrete placement will ...
PBF Reactor Building (PER-620). Camera faces southeast. Concrete placement will leave opening for neutron camera to be installed later. Note vertical piping within rebar. Photographer: John Capek. Date: July 6, 1967. INEEL negative no. 67-3514 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Aerial view of early construction. Camera ...
PBF Reactor Building (PER-620). Aerial view of early construction. Camera facing northwest. Excavation and concrete placement in two basements are underway. Note exposed lava rock. Photographer: Farmer. Date: March 22, 1965. INEEL negative no. 65-2219 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Reactor vessel arrives from gate city ...
PBF Reactor Building (PER-620). Reactor vessel arrives from gate city steel at door of PBF. On flatbed, it is too high to fit under door. Photographer: Larry Page. Date: February 13, 1970. INEEL negative no. 70-737 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Camera faces north into highbay/reactor pit ...
PBF Reactor Building (PER-620). Camera faces north into high-bay/reactor pit area. Inside from for reactor enclosure is in place. Photographer: John Capek. Date: March 15, 1967. INEEL negative no. 67-1769 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Camera facing south end of high ...
PBF Reactor Building (PER-620). Camera facing south end of high bay. Vertical-lift door is being installed. Later, pneumatic seals will be installed around door. Photographer: Kirsh. Date: September 31, 1968. INEEL negative no. 68-3176 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI plot plan for control area. Includes Control Building (PER601), ...
SPERT-I plot plan for control area. Includes Control Building (PER-601), Gate House (PER-603), well sand settling tank, substation, and septic system. Date: February 1955. INEEL index no. 760-0101-00-396-109104 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
90. ARAIII. GCRE reactor building (ARA608) mechanical loop pit. Shows ...
90. ARA-III. GCRE reactor building (ARA-608) mechanical loop pit. Shows nitrogen gas compressor in foreground, piping installations on walls of pit, and other details. February 24, 1959. Ineel photo no. 59-880. Photographer: Ken Mansfield. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
LOFT. Reactor arrives at containment building (TAN650), now being pushed ...
LOFT. Reactor arrives at containment building (TAN-650), now being pushed by locomotive. Camera facing northerly. Note "Hello Dolly" and "PWR MTA No. 1" (pressurized water reactor mobile test assembly) signs. Date: 1973. INEEL negative no. 73-3710 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
HOT CELL BUILDING, TRA632. ELEVATIONS FOR SOUTH, NORTH AND WEST ...
HOT CELL BUILDING, TRA-632. ELEVATIONS FOR SOUTH, NORTH AND WEST SIDES OF 1958 EXTENSION. H.K. FERGUSON CO. 895-MTR-ETR-632-A3, 12/1958. INL INDEX NO. 531-0632-00-279-101926, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
CANAL EMERGES FROM EAST SIDE OF MTR BUILDING. "EXTRA" LENGTH ...
CANAL EMERGES FROM EAST SIDE OF MTR BUILDING. "EXTRA" LENGTH WAS TO STORE SPENT FUEL THAT WOULD ACCUMULATE BEFORE THE CHEMICAL PROCESSING PLANT WAS READY TO PROCESS IT. INL NEGATIVE NO. 1659. Unknown Photographer, 3/9/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
168. ARAIV Index of drawings prepared by Norman Engineering Company ...
168. ARA-IV Index of drawings prepared by Norman Engineering Company in preparation for construction of ARA-IV. Norman Engineering Company 961-area/ML-1index. Date: March 1961. Ineel index code no. 066-9999-90-613-102731. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Reactor Building (PER620) as seen from control room window ...
PBF Reactor Building (PER-620) as seen from control room window in PER-619. Photographer stood just outside window. Note exposed communication cables on desert surface. Date: July 2004. INEEL negative no. HD-41-9-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
STEEL BEAMS FOR FIRST FLOOR BEING READIED FOR CONCRETE POUR ...
STEEL BEAMS FOR FIRST FLOOR BEING READIED FOR CONCRETE POUR UNDER WEATHER SHELTER DURING COLD WINTER. NOTE ABUNDANCE OF BEAMS; THE FLOOR WILL SUPPORT HEAVY LOADS. INL NEGATIVE NO. 1175. Unknown Photographer, 12/20/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR CRITICAL FACILITY (ETRCF), TRA654. SOUTH SIDE. CAMERA FACING NORTH ...
ETR CRITICAL FACILITY (ETR-CF), TRA-654. SOUTH SIDE. CAMERA FACING NORTH AND ROLL-UP DOOR. ORIGINAL SIDING HAS BEEN REPLACED WITH STUCCO-LIKE MATERIAL. INL NEGATIVE NO. HD46-40-1. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR WING A, TRA604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE ...
MTR WING A, TRA-604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE LABORATORY 114. CAMERA FACING NORTH. DISPOSAL OF RADIOACTIVE MATERIALS IS UNDERWAY. INL NEGATIVE NO. HD46-12-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
26. VIEW OF METAL SHED OVER SHIELDING TANK WITH CAMERA ...
26. VIEW OF METAL SHED OVER SHIELDING TANK WITH CAMERA FACING SOUTHWEST. SHOWS OPEN SIDE OF SHED ROOF, HERCULON SHEET, AND HAND-OPERATED CRANE. TAKEN IN 1983. INEL PHOTO NUMBER 83-476-2-9, TAKEN IN 1983. PHOTOGRAPHER NOT NAMED. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
LOFT. Containment and service building (TAN650). Sections H, K, and ...
LOFT. Containment and service building (TAN-650). Sections H, K, and L; details of pre-amp tower. Kaiser engineers 6413-11-STEP/LOFT-650-A-14. Date: January 1966. INEEL index code no. 036-650-00-486-122226 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
147. ARAIII Control building (ARA607) Detail of instrument rack and ...
147. ARA-III Control building (ARA-607) Detail of instrument rack and control console in control room. Aerojet-general 880-area/GCRE-607-E-4. Date: November 1958. Ineel index code no. 063-0607-10-013-102560. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Cooling Tower. Camera facing southwest. Round piers will support ...
PBF Cooling Tower. Camera facing southwest. Round piers will support Tower's wood "fill" or "packing." Black-topped stack in far distance is at Idaho Chemical Processing Plant. Photographer: John Capek. Date: October 16, 1968. INEEL negative no. 68-4097 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
LOFT. Containment and service building (TAN650) basement floor plan. Basement ...
LOFT. Containment and service building (TAN-650) basement floor plan. Basement airlock, shielded roadway, service areas, connection to control building. Kaiser engineers 6413-11-STEP/LOFT-650-A-1. Date: October 1964. INEEL index code no. 036-650-00-416-122213 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Technical service laboratory in administration building (TAN602). Floor plan, ...
A&M. Technical service laboratory in administration building (TAN-602). Floor plan, reception desk, door and finish schedules. Ralph M. Parsons 1480-12-ANP/GE-3-602-A-1. INEEL index code no. 033-0602-00-693-107488 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
155. ARAIII Reactor building (ARA608) Details of reactor pit showing ...
155. ARA-III Reactor building (ARA-608) Details of reactor pit showing tray supports and fuel element storage rack. Aerojet-general 880-area/GCRE-608-MS-2. Date: November 1958. Ineel index code no. 063-0608-40-013-102625. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
160. ARAIII Service building (ARA610). Includes floor plan, north and ...
160. ARA-III Service building (ARA-610). Includes floor plan, north and west elevations, and section details. Aerojet-general 880-area/GCRE-610-A-1. Date: February 1958. Ineel index code no. 063-0610-00-013-102684. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
A&M. Gate House (TAN601). Plan, elevations, sections, details. Shows expanded ...
A&M. Gate House (TAN-601). Plan, elevations, sections, details. Shows expanded building as attached to TAN-602. Ralph M. Parsons 902-2-ANP-601-A 22. Date: December 1952. INEEL index code no. 033-0602-00-693-106704 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR ...
36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR PLAN AND VICINITY PLAN RELATIONSHIP TO ADMINISTRATION AND MAINTENANCE AREA. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-629-A-2. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
ADM. Change House (TAN606) as completed. Camera facing northerly. Note ...
ADM. Change House (TAN-606) as completed. Camera facing northerly. Note proximity to shielding berm. Part of hot shop (A&M Building, TAN-607) at left of view beyond berm. Date: October 29, 1954. INEEL negative no. 12705 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PBF Reactor Building (PER620). Cubicle 10 detail. Camera facing west ...
PBF Reactor Building (PER-620). Cubicle 10 detail. Camera facing west toward brick shield wall. Valve stems against wall penetrate through east wall of cubicle. Photographer: John Capek. Date: August 19, 1970. INEEL negative no. 70-3469 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
SPERTI Reactor Pit Building (PER605) from contrasting direction as photo ...
SPERT-I Reactor Pit Building (PER-605) from contrasting direction as photo above (ID-33-F-32). Note Guard House door, security fencing around facility. Photographer: R.G. Larsen. Date: July 22, 1955. INEEL negative no. 55-1702. - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ETRCF, TRA654, INTERIOR. REACTOR OPERATED IN WATERFILLED TANK. CAMERA LOOKS ...
ETR-CF, TRA-654, INTERIOR. REACTOR OPERATED IN WATER-FILLED TANK. CAMERA LOOKS DOWN FROM ABOVE UPON LATER (NON-NUCLEAR) EXPERIMENTAL GEAR. INL NEGATIVE NO. HD24-1-1. Mike Crane, Photographer, ca. 2003 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE OF ETR REACTOR, CAMERA FACING NORTH. CABINET CONTAINING "NUCLEAR INSTRUMENT SYSTEMS" IS RESTRICTED. INL NEGATIVE NO. HD46-18-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
COMPRESSOR BUILDING, TRA626. ELEVATIONS. WINDOWS. WALL SECTIONS. PUMICE BLOCK BUILDING ...
COMPRESSOR BUILDING, TRA-626. ELEVATIONS. WINDOWS. WALL SECTIONS. PUMICE BLOCK BUILDING HOUSED COMPRESSORS FOR AIRCRAFT NUCLEAR PROPULSION EXPERIMENTS. MTR-626-IDO-2S, 3/1952. INL INDEX NO. 531-0626-00-396-110535, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR, SOUTH FACE OF REACTOR. SPECIAL SUPPLEMENTAL SHIELDING WAS REQUIRED ...
MTR, SOUTH FACE OF REACTOR. SPECIAL SUPPLEMENTAL SHIELDING WAS REQUIRED OUTSIDE OF MTR FOR EXPERIMENTS. THE AIRCRAFT NUCLEAR PROPULSION PROJECT DOMINATED THE USE OF THIS PART OF THE MTR. INL NEGATIVE NO. 7225. Unknown Photographer, 11/28/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
HOT CELL BUILDING, TRA632, INTERIOR. CELL 3, "HEAVY" CELL. CAMERA ...
HOT CELL BUILDING, TRA-632, INTERIOR. CELL 3, "HEAVY" CELL. CAMERA FACES WEST TOWARD BUILDING EXIT. OBSERVATION WINDOW AT LEFT EDGE OF VIEW. INL NEGATIVE NO. HD46-28-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Predisposing Risk Factors for Non-Contact ACL Injuries in Military Subjects
2011-01-01
with activity: epidemiology of anterior cruciate ligament injuries in a young, athletic population. Am J Sports Med 35:1635–1642 21. Nicholas JA (1970...Bilaterality in anterior cruciate ligament injuries: associated intercondylar notch steno - sis. Am J Sports Med 16:449–454 27. Uhorchak JM, Scoville CR
A&M. Guard house (TAN638), contextual view. Built in 1968. Camera ...
A&M. Guard house (TAN-638), contextual view. Built in 1968. Camera faces south. Guard house controlled access to radioactive waste storage tanks beyond and to left of view. Date: February 4, 2003. INEEL negative no. HD-33-4-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LOFT. Reactor apparatus leaves A&M building (TAN607). Shielded locomotive has ...
LOFT. Reactor apparatus leaves A&M building (TAN-607). Shielded locomotive has aerojet logo, which replaced old general electric logo, pulls reactor from assembly shop on dolly. Camera facing easterly. Date: 1973. INEEL negative no. 73-3700 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD ...
PROCESS WATER BUILDING, TRA-605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4219. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
STORAGE AND RECIEVING, TRA662. ELEVATIONS. LOWBAY SECTION ON SOUTH SIDE ...
STORAGE AND RECIEVING, TRA-662. ELEVATIONS. LOW-BAY SECTION ON SOUTH SIDE WAS FLAMMABLE STORAGE AREA. HUMMEL HUMMEL & JONES 1038-MTR-ETR-662-A-3, 6/1960. INL INDEX NO. 532-0653-00-381-102036, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PBF Reactor Building (PER620). Detail of arrangement of highdensity blocks ...
PBF Reactor Building (PER-620). Detail of arrangement of high-density blocks and other basement shielding. Date: February 1966. Ebasco Services 1205 PER/PBF 620-A-7. INEEL index no. 761-0620-00-205-123070 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
FAST CHOPPER BUILDING, TRA665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. ...
FAST CHOPPER BUILDING, TRA-665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. MTR REACTOR SERVICES BUILDING,TRA-635, TO LEFT; MTR BUILDING TO RIGHT. CAMERA FACING WEST. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
LPT. Low power test control building (TAN641) interior. Camera facing ...
LPT. Low power test control building (TAN-641) interior. Camera facing northeast at what remains of control room console. Cut in wall at right of view shows west wall of northern test cell. INEEL negative no. HD-40-4-4 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Combined orbits and clocks from IGS second reprocessing
NASA Astrophysics Data System (ADS)
Griffiths, Jake
2018-05-01
The Analysis Centers (ACs) of the International GNSS Service (IGS) have reprocessed a large global network of GPS tracking data from 1994.0 until 2014.0 or later. Each AC product time series was extended uniformly till early 2015 using their weekly operational IGS contributions so that the complete combined product set covers GPS weeks 730 through 1831. Three ACs also included GLONASS data from as early as 2002 but that was insufficient to permit combined GLONASS products. The reprocessed terrestrial frame combination procedures and results have been reported already, and those were incorporated into the ITRF2014 multi-technique global frame released in 2016. This paper describes the orbit and clock submissions and their multi-AC combinations and assessments. These were released to users in early 2017 in time for the adoption of IGS14 for generating the operational IGS products. While the reprocessing goal was to enable homogeneous modeling, consistent with the current operational procedures, to be applied retrospectively to the full history of observation data in order to achieve a more suitable reference for geophysical studies, that objective has only been partially achieved. Ongoing AC analysis changes and a lack of full participation limit the consistency and precision of the finished IG2 products. Quantitative internal measures indicate that the reprocessed orbits are somewhat less precise than current operational orbits or even the later orbits from the first IGS reprocessing campaign. That is even more apparent for the clocks where a lack of robust AC participation means that it was only possible to form combined 5-min clocks but not the 30-s satellite clocks published operationally. Therefore, retrospective precise point positioning solutions by users are not recommended using the orbits and clocks. Nevertheless, the orbits do support long-term stable user solutions when used with network processing with either double differencing or explicit clock estimation. Among the main benefits of the reprocessing effort is a more consistent long product set to analyze for sources of systematic error and accuracy. Work to do that is underway but the reprocessing experience already points to a number of ways future IGS performance and reprocessing campaigns can be improved.
AirMSPI Level 1B2 V003 New and Reprocessed Data
Atmospheric Science Data Center
2013-12-10
AirMSPI Level 1B2 V003 New and Reprocessed Data PODEX Thursday, December 12, ... The V001 & V002 data were reprocessed as V003, as well as new Pacific targets acquired on February 1, 2013. This release also includes both a terrain and an ellipsoid kml file per date/time/target. More details about the PODEX campaign and AirMSPI participation can be ...
RXTE and BeppoSAX Observations of MCG-5-23-16: Reflection From Distant Cold Material
NASA Technical Reports Server (NTRS)
Mattson, B. J.; Weaver, K. A.
2003-01-01
We examine the spectral variability of the Seyfert 1.9 galaxy MCG-5-23-16 using RXTE and BeppoSAX observations spanning 2 years from April 1996 to April 1998. During the first year the X-ray source brightens by a factor of approximately 25% on timescales of days to months. During this time, the reprocessed continuum emission seen with RXTE does not respond measurably to the continuum increase. However, by the end of the second year during the BeppoSAX epoch the X-ray source has faded again. This time, the reprocessed emission has also faded, indicating that the reprocessed flux has responded to the continuum. If these effects are caused by time delays due to the distance between the X-ray source and the reprocessing region, we derive a light crossing time of between approximately 1 light day and approximately 1.5 light years. This corresponds to a distance of 0.001 pc to 0.55 pc, which implies that the reprocessed emission originates between 3 x 10(exp 15) cm and 1.6 x 10(exp l8) cm from the X-ray source. In other words, the reprocessing in MCG-5-23-16 is not dominated by the inner regions of a standard accretion disk.
Zumtobel, Michaela; Assadian, Ojan; Leonhard, Matthias; Stadler, Maria; Schneider, Berit
2009-07-25
The surface of polymeric tracheotomy tubes is a favourable environment for biofilm formation and therefore represents a potential risk factor for the development of pneumonia after tracheotomy. The aim of this in-vitro study was to develop octenidine-dihydrochloride (OCT) coated polymer tracheotomy tubes and investigate any effects on Staphylococcus (S.) aureus and Pseudomonas (P.) aeruginosa colonization. Additionally the resistance of the OCT coating was tested using reprocessing procedures like brushing, rinsing and disinfection with glutaraldehyde Contamination with S. aureus: Before any reprocessing, OCT coated tracheotomy tubes were colonized with 103 cfu/ml and uncoated tracheotomy tubes with 105 cfu/ml (P = 0.045). After reprocessing, no differences in bacterial concentration between modified and conventional tubes were observed.Contamination with P. aeruginosa: Before reprocessing, OCT coated tubes were colonized with 106 cfu/ml and uncoated tubes with 107 cfu/ml (P = 0.006). After reprocessing, no significant differences were observed. OCT coating initially inhibits S. aureus and P. aeruginosa colonisation on tracheotomy tubes. This effect, however, vanishes quickly after reprocessing of the tubes due to poor adhesive properties of the antimicrobial compound. Despite the known antimicrobial effect of OCT, its use for antimicrobial coating of tracheotomy tubes is limited unless methods are developed to allow sustained attachment to the tube.
Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing.
Ofstead, Cori L; Wetzler, Harry P; Johnson, Ellen A; Heymann, Otis L; Maust, Thomas J; Shaw, Michael J
2016-11-01
During a study designed to assess endoscope reprocessing effectiveness, a borescope was used to examine lumens and ports. Cloudy, white, viscous fluid was observed inside fully reprocessed gastroscopes and colonoscopes. This fluid resembled simethicone, which is commonly administered to reduce foam and bubbles that impede visualization during gastrointestinal endoscopy. This article describes methods used to determine whether the observed fluid contained simethicone. Photographs of residual fluid were taken using a borescope. Sterile cotton-tipped swabs were used to collect samples of fluid observed in 3 endoscope ports. Samples were evaluated using Fourier transform infrared spectroscopy (FTIR)-attenuated total reflection analysis. Residual fluid was observed inside 19 of 20 endoscopes. Fluid photographed in 8 endoscopes resembled simethicone solutions. FTIR analysis confirmed the presence of simethicone in 2 endoscopes. Fluid containing simethicone remained inside endoscopes despite reprocessing. Simethicone is an inert, hydrophobic substance that may reduce reprocessing effectiveness. Simethicone solutions commonly contain sugars and thickeners, which may contribute to microbial growth and biofilm development. Studies are needed to assess the prevalence of residual moisture and simethicone in endoscopes and determine the impact on reprocessing effectiveness. We recommend minimizing the use of simethicone pending further research into its safety. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Complex UV/X-ray variability of 1H 0707-495
NASA Astrophysics Data System (ADS)
Pawar, P. K.; Dewangan, G. C.; Papadakis, I. E.; Patil, M. K.; Pal, Main; Kembhavi, A. K.
2017-12-01
We study the relationship between the UV and X-ray variability of the narrow-line Seyfert 1 galaxy 1H 0707-495. Using a year-long Swift monitoring and four long XMM-Newton observations, we perform cross-correlation analyses of the UV and X-ray light curves, on both long and short time-scales. We also perform time-resolved X-ray spectroscopy on 1-2 ks scale, and study the relationship between the UV emission and the X-ray spectral components - soft X-ray excess and a power law. We find that the UV and X-ray variations anticorrelate on short, and possibly on long time-scales as well. Our results rule out reprocessing as the dominant mechanism for the UV variability, as well as the inward propagating fluctuations in the accretion rate. Absence of a positive correlation between the photon index and the UV flux suggests that the observed UV emission is unlikely to be the seed photons for the thermal Comptonization. We find a strong correlation between the continuum flux and the soft-excess temperature which implies that the soft excess is most likely the reprocessed X-ray emission in the inner accretion disc. Strong X-ray heating of the innermost regions in the disc, due to gravitational light bending, appears to be an important effect in 1H 0707-495, giving rise to a significant fraction of the soft excess as reprocessed thermal emission. We also find indications for a non-static, dynamic X-ray corona, where either the size or height (or both) vary with time.
Complex optical/UV and X-ray variability of the Seyfert 1 galaxy 1H 0419-577
NASA Astrophysics Data System (ADS)
Pal, Main; Dewangan, Gulab C.; Kembhavi, Ajit K.; Misra, Ranjeev; Naik, Sachindra
2018-01-01
We present detailed broad-band UV/optical to X-ray spectral variability of the Seyfert 1 galaxy 1H 0419-577 using six XMM-Newton observations performed during 2002-2003. These observations covered a large amplitude variability event in which the soft X-ray (0.3-2 keV) count rate increased by a factor of ∼4 in six months. The X-ray spectra during the variability are well described by a model consisting of a primary power law, blurred and distant reflection. The 2-10 keV power-law flux varied by a factor of ∼7 while the 0.3-2 keV soft X-ray excess flux derived from the blurred reflection component varied only by a factor of ∼2. The variability event was also observed in the optical and UV bands but the variability amplitudes were only at the 6-10 per cent level. The variations in the optical and UV bands appear to follow the variations in the X-ray band. During the rising phase, the optical bands appear to lag behind the UV band but during the declining phase, the optical bands appear to lead the UV band. Such behaviour is not expected in the reprocessing models where the optical/UV emission is the result of reprocessing of X-ray emission in the accretion disc. The delayed contribution of the broad emission lines in the UV band or the changes in the accretion disc/corona geometry combined with X-ray reprocessing may give rise to the observed behaviour of the variations.
Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method.
Parohl, Nina; Stiefenhöfer, Doris; Heiligtag, Sabine; Reuter, Henning; Dopadlik, Dana; Mosel, Frank; Gerken, Guido; Dechêne, Alexander; Heintschel von Heinegg, Evelyn; Jochum, Christoph; Buer, Jan; Popp, Walter
2017-01-01
Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from routine clinical use in a major university hospital in Germany. Endoscopes have been assessed with an ATP system and microbial cultures at different timepoints during the reprocessing. Findings: After the bedside flush the mean ATP level in relative light units (RLU) was 19,437 RLU, after the manual cleaning 667 RLU and after the automated endoscope reprocessor (AER) 227 RLU. After the manual cleaning the mean total viable count (TVC) per endoscope was 15.3 CFU/10 ml, and after the AER 5.7 CFU/10 ml. Our results show that there are reprocessing cycles which are not able to clean a patient used endoscope. Conclusion: Our data suggest that monitoring of flexible endoscope with ATP can identify a number of different influence factors, like the endoscope condition and the endoscopic procedure, or especially the quality of the bedside flush and manual cleaning before the AER. More process control is one option to identify and improve influence factors to finally increase the overall reprocessing quality, best of all by different methods. ATP measurement seems to be a valid technique that allows an immediate repeat of the manual cleaning if the ATP results after manual cleaning exceed the established cutoff of 200 RLU.
Phillips, M
2001-01-01
This paper explores how hypnotic principles can be systematically incorporated into the standard EMDR protocol to enhance various ego strength capacities during EMDR treatment. Expanding these skill areas can widen the therapeutic window of possibility for clients with a variety of complex clinical issues, including posttraumatic, dissociative or personality disorders, anxiety symptoms, and depressive difficulties. Clinical case examples are used to illustrate ways of integrating hypnotic principles within a proposed EMDR protocol to promote ego strengthening and facilitate therapeutic change.
Determining the minimum in situ stress from hydraulic fracturing through perforations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warpinski, N.R.
Hydraulic fracture stress measurements have been performed through perforations at depths from 1310 to 2470 m at the US Department of Energy's Multiwell Experiment site. The results of over sixty stress tests conducted through perforations have shown that small-volume hydraulic fractures generally provide an accurate, reproducible measurement of the minimum in situ stress. However, unusual behavior can occur in some tests and techniques to evaluate the behavior are suggested. Unclear instantaneous shut-in pressures, which are found on occasional tests, are difficult to evaluate, but the problem appears to be a complex stress state; reprocessing the data using log-log or othermore » functions does not necessarily provide the correct stress value. The possible error in such tests should be assessed from the original pressure-time data and not the reprocessing techniques. Stress results show that the stress distribution is dependent on lithology at this site; mudstones, shales and other nonreservoir rocks generally have a near-lithostatic stress, while sandstones have a considerably lower minimum stress value. 30 refs., 18 figs., 4 tabs.« less
LPT. Low power assembly and test building (TAN640). Camera facing ...
LPT. Low power assembly and test building (TAN-640). Camera facing west. Rollup doors to each test cell face east. Concrete walls poured in place. Apparatus at right of view was part of a post-ANP program. INEEL negative no. HD-40-1-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Shield test facility assembly and test building (TAN646), south ...
LPT. Shield test facility assembly and test building (TAN-646), south facade. Camera facing north. High-bay section is pool room. Single-story section at right is control building (TAN-645). Small metal building is post-1970 addition. INEEL negative no. HD-40-7-3 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
44. ARAIII Fuel oil tank ARA710. Camera facing west. Perimeter ...
44. ARA-III Fuel oil tank ARA-710. Camera facing west. Perimeter fence at left side of view. Gable-roofed building beyond tank on right is ARA-622. Gable-roofed building beyond tank on left is ARA-610. Ineel photo no. 3-16. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
114. ARAI Hot cell (ARA626) Building details of fuel storage ...
114. ARA-I Hot cell (ARA-626) Building details of fuel storage pit in plan and section. Spaces shown for 20 elements. Norman Engineering Company: 961-area/SF-626-S-4. Date: January 1959. Ineel index code no. 068-0626-60-613-102752. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Reactor Building (PER620). Cubicle 10 area in basement. Highdensity ...
PBF Reactor Building (PER-620). Cubicle 10 area in basement. High-density shielding bricks will protect personnel from radiation coming from in-pile-tube coolant and blowdown tank. Photographer: John Capek. Date: January 26, 1970. INEEL negative no. 70-348 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. BASEMENT. CORRIDOR ALONG WEST WALL OF ...
ETR BUILDING, TRA-642, INTERIOR. BASEMENT. CORRIDOR ALONG WEST WALL OF BUILDING, WHICH IS AT RIGHT OF VIEW. AUDIO ALARM IS ALONG WALL AT RIGHT. CAMERA FACES SOUTH. INL NEGATIVE NO. HD46-30-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
72. ARAII. Interior view in ARA602 support building showing oilfired ...
72. ARA-II. Interior view in ARA-602 support building showing oil-fired hot air furnace and hot water boiler in foreground; hot water tank and diesel generator in background. December 12, 1957. Ineel photo no. 57-6099. Photographer: Jack L. Anderson. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Control Building (PER619). Interior detail of control room's severe ...
PBF Control Building (PER-619). Interior detail of control room's severe fuel damage instrument panel. Indicators provided real-time information about test underway in PBF reactor. Note audio speaker. Date: May 2004. INEEL negative no, HD-41-7-4 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ADM. Tanks: from left to right: fuel oil tank, fuel ...
ADM. Tanks: from left to right: fuel oil tank, fuel pump house (TAN-611), engine fuel tank, water pump house, water storage tank. Camera facing northwest. Not edge of shielding berm at left of view. Date: November 25, 1953. INEEL negative no. 9217 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PBF Reactor Building (PER620). Detail of fuel test assembly in ...
PBF Reactor Building (PER-620). Detail of fuel test assembly in preparation for test. When complete, it will fit into in-pile tube. The maximum outside diameter of which must be about 8.25 inches. Date: 1982. INEEL negative no. 82-4908 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
MTR WING A, TRA604. SOUTH SIDE. CAMERA FACING NORTH. THIS ...
MTR WING A, TRA-604. SOUTH SIDE. CAMERA FACING NORTH. THIS VIEW TYPIFIES TENDENCY FOR EXPANSIONS TO TAKE THE FORM OF PROJECTIONS AND INFILL USING AVAILABLE YARD SPACES. INL NEGATIVE NO. HD47-44-3. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR, TRA603. CONTROL ROOM DETAILS. ACOUSTIC PLASTER CEILING, USHAPED CONSOLE, ...
MTR, TRA-603. CONTROL ROOM DETAILS. ACOUSTIC PLASTER CEILING, U-SHAPED CONSOLE, INSTRUMENT PANELS, GLASS DOOR, ASPHALT TILE FLOOR AND COLORS. BLAW-KNOX 3150-803-11, 10/1950. INL INDEX NO. 531-0603-00-098-100570, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
IET. Periscope shielding and installation details. Shows range of scanning ...
IET. Periscope shielding and installation details. Shows range of scanning head, removable concrete cap, concrete shielding. Ralph M. Parsons 902-4-ANP-620-A 324. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL Index code no. 035-0620-00-693-106909 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Shield test facility (TAN645 and 646). Calibration lab shield ...
LPT. Shield test facility (TAN-645 and -646). Calibration lab shield door. Ralph M. Parsons 1229-17 ANP/GE-6-645-MS-1. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645-40-693-107369 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Shield test facility (TAN645 and 646). Floor plan and ...
LPT. Shield test facility (TAN-645 and -646). Floor plan and room names. Ralph M. Parsons 1229-17 ANP/GE-6-645-A-1. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645/0646-00-693-107347 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
FET. Tank Building, TAN631. Elevations, sections, details. Tank pads and ...
FET. Tank Building, TAN-631. Elevations, sections, details. Tank pads and saddles. RAlph M. Parsons 1229-2 ANP/GE-5-631-A-1. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0631-00-693-107142 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Guard House (TAN642). Elevations, floor plan, sections, details. Ralph ...
LPT. Guard House (TAN-642). Elevations, floor plan, sections, details. Ralph M. Parsons 1229-12 ANP/GE-7-642-A-S-H7V-1. November 1956. Approved by INEEL Classification Office for public release. INEEL index code no. 038-0642-00-693-107306 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Demineralization plant, TAN649. Floor plan, elevation details. Ralph M. ...
A&M. Demineralization plant, TAN-649. Floor plan, elevation details. Ralph M. Parsons 1480-4-ANP/GE-3-649-A-1. Date: October 1958. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0649-00-693-107439 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET. Control and equipment building (TAN620) floor plan. Schedule of ...
IET. Control and equipment building (TAN-620) floor plan. Schedule of furniture and equipment. Ralph M. Parsons 902-4-ANP-A 320. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0620-00-693-106905 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Radioactive parts security storage area, heat removal storage casks. ...
A&M. Radioactive parts security storage area, heat removal storage casks. Plan, section, and details. Ralph M. Parsons 1480-7 ANP/GE-3-720-S-1. Date: November 1958. Approved by INEEL Classification Office for public release. INEEL index no. 034-0720-60-693-107459 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
HEAT EXCHANGER BUILDING, TRA644. NORTHEAST CORNER. CAMERA IS ON PIKE ...
HEAT EXCHANGER BUILDING, TRA-644. NORTHEAST CORNER. CAMERA IS ON PIKE STREET FACING SOUTHWEST. ATTACHED STRUCTURE AT RIGHT OF VIEW IS ETR COMPRESSOR BUILDING, TRA-643. INL NEGATIVE NO. HD46-36-4. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
86. ARAIII. GCRE reactor building (ARA608) showing mechanical loop pit ...
86. ARA-III. GCRE reactor building (ARA-608) showing mechanical loop pit after building shell had been erected. Beyond pit are demineralized water surge tank and heat exchanger. Camera facing northeast. December 22, 1958. Ineel photo no. 58-6427. Photographer: Ken Mansfield. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
129. ARAII Administrative and technical support building (ARA606) sections showing ...
129. ARA-II Administrative and technical support building (ARA-606) sections showing roof and wall details and longitudinal section. C.A. Sundberg and Associates 866-area/ALPR-606-A-5. Date: May 1958. Ineel index code no. 070-0606-00-822-102828. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
142. ARAIII General plan of GCRE area, including electrical distribution ...
142. ARA-III General plan of GCRE area, including electrical distribution plan for power and lighting. Includes detail of floodlight and security lighting poles and fixtures. Aerojet-general 880-area/GCRE-406-1. Date: February 1958. Ineel index code no. 063-0406-00-013-102539. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
121. ARAI Guard house (ARA628). Drawing shows north, south, east, ...
121. ARA-I Guard house (ARA-628). Drawing shows north, south, east, and west elevations, floor plan, counter details, and roof plan. Norman Engineering Corporation 961-area/SF-628-A-1. Date: January 1959. Ineel index code no. 063-0628-00-613-102772. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
37. ELECTRICAL PLAN AND DETAILS. SHOWS PLANNED LOCATION OF PORTABLE ...
37. ELECTRICAL PLAN AND DETAILS. SHOWS PLANNED LOCATION OF PORTABLE GENERATOR. FUNCTION OF FOUR-FOOT SQUARE PIT IS SHOWN AS 'D.C. POWER SUPPLY PIT.' F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-E-1. INEL INDEX CODE NUMBER: 075 0701 10 851 151973. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
145. ARAIII Control building (ARA607) Sections. Shows highbay section of ...
145. ARA-III Control building (ARA-607) Sections. Shows high-bay section of building over crane rail and beam. Indicates materials of exterior siding. Aerojet-general 880-area/GCRE-607-A-11. Date: February 1958. Ineel index code no. 063-0607-00-013-102556. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
128. ARAII Administrative and technical support building (ARA606) elevations for ...
128. ARA-II Administrative and technical support building (ARA-606) elevations for northwest, southwest, northeast, and southeast sides. C.A. Sundberg and Associates 866-area/ALPR-606-A-3. Date: May 1958. Ineel index code no. 070-0606-00-822-102826. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
47. ARAI. Interior view of operating wall of hot cell ...
47. ARA-I. Interior view of operating wall of hot cell in ARA-626. Note stands for operators at viewing windows. Manipulators with hand grips extend cables and other controls into hot cell through ducts above windows. Ineel photo no. 81-27. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF (PER620) interior. Detail view across top of reactor tank. ...
PBF (PER-620) interior. Detail view across top of reactor tank. Camera facing northeast. Ait tubing is cleanup equipment. Note projections from reactor structure above water level in tank. Date: May 2004. INEEL negative no. HD-41-5-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PBF Cooling Tower (PER720) and its Auxiliary Building (PER625). Camera ...
PBF Cooling Tower (PER-720) and its Auxiliary Building (PER-625). Camera facing west shows east facades. Center pipe carried secondary coolant water from reactor. Building to distributor basin. Date: August 2003. INEEL negative no. HD-35-10-1 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
General layout of reactor and control areas upon advent of ...
General layout of reactor and control areas upon advent of power burst facility (PBF). Shows relationship of PBF to SPERT-I, -II, -III, and -IV. Ebasco Services 1205-PER/PBF-U-102. Date: July 1965. INEEL index no. 761-0100-00-205-123006 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
ETRMTR MECHANICAL SERVICES BUILDING, TRA653, INTERIOR. CAMERA IS INSIDE MEN'S ...
ETR-MTR MECHANICAL SERVICES BUILDING, TRA-653, INTERIOR. CAMERA IS INSIDE MEN'S LAVATORY AND SHOWER FACING SOUTHEAST. SHOWER AND TOILET STALLS ARE IN PLACE. ROUND COMMUNAL SINK AT LEFT. INL NEGATIVE NO. 57-3652. K. Mansfield, Photographer, 7/22/1957 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
IET exhaust gas stack. Section, west elevation, foundation plan, access ...
IET exhaust gas stack. Section, west elevation, foundation plan, access ladder, airplane warning light. Ralph M. Parsons 902-5-ANP-712-S 433. Date: May 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0712-60-693-106984 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LOFT. Containment building entry, an adapted use of TAN624, which ...
LOFT. Containment building entry, an adapted use of TAN-624, which originated as the mobile test building for the ANP program. Camera facing north. Note four-rail track entered building stack at right of view. Date: March 2004. INEEL negative no. HD-39-4-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
PBF Cooling Tower (PER720), and Auxiliary Building (PER624). Camera faces ...
PBF Cooling Tower (PER-720), and Auxiliary Building (PER-624). Camera faces north to show south facades. Oblong vertical structure at left of center is weather shield for stairway. Date: August 2003. INEEL negative no. HD-35-10-4 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
REACTOR SERVICE BUILDING, TRA635. CROWDED MOCKUP AREA. CAMERA FACES EAST. ...
REACTOR SERVICE BUILDING, TRA-635. CROWDED MOCK-UP AREA. CAMERA FACES EAST. PHOTOGRAPHER'S NOTE SAYS "PICTURE REQUESTED BY IDO IN SUPPORT OF FY '58 BUILDING PROJECTS." INL NEGATIVE NO. 56-3025. R.G. Larsen, Photographer, 9/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. TAN607. Detail of installed hot shop viewing window almost ...
A&M. TAN-607. Detail of installed hot shop viewing window almost complete. Cable channel is still exposed, lacking cover. Note bottle in upper left corner containing spare zinc bromide in even of leak from window. Date: October 20, 1954. INEEL negative no. 12560 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LPT. Shield test facility (TAN646). Sections and details of water ...
LPT. Shield test facility (TAN-646). Sections and details of water management areas. Ralph M. Parsons 1229-17 ANP/GE-6-646-P-3. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0646-51-693-107388 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
77. ARAII. Room at northeast corner of ARA606 used for ...
77. ARA-II. Room at northeast corner of ARA-606 used for welding training and welding procedure qualification and performance testing. This was only building in use at ARA-II by 1983. Date: 1983. Ineel photo no. 83-476-3-5. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
LOFT, TAN650. Service building preamp tower, top three floors. Floor ...
LOFT, TAN-650. Service building pre-amp tower, top three floors. Floor plan, cable mazes, duct labyrinth. Borated water tank enclosure on roof. Kaiser engineers 6413-11-STEP/LOFT-650-A-3. Date: October 1964. INEEL index code no. 036-650-00-486-122215 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
SPERTI Control Building (PER601) interior. Control panel with data readout ...
SPERT-I Control Building (PER-601) interior. Control panel with data readout equipment in control room. Panels and equipment were fabricated elsewhere at NRTS during SPERT-I construction. Photographer: R.G. Larsen. Date: November 21, 1955. INEEL negative no. 55-3208 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
IET control building (TAN620). control room. facing north. control consoles ...
IET control building (TAN-620). control room. facing north. control consoles have been removed. Openings in floor were communication and control conduits. Periscope controls at center left (see also HAER No. ID-33-E-20). INEEL negative no. HD-21-3-1 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
27. AERIAL VIEW OF ARVFS FIELD TEST SITE AS IT ...
27. AERIAL VIEW OF ARVFS FIELD TEST SITE AS IT LOOKED IN 1983. OBLIQUE VIEW FACING EAST. BUNKER IS IN FOREGROUND, PROTECTIVE SHED FOR WFRP AT TOP OF IMAGE. INEL PHOTO NUMBER 83-574-12-1, TAKEN IN 1983. PHOTOGRAPHER: ROMERO. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID
150. ARAIII Reactor building (ARA608) Sections. Show highbay section, heater ...
150. ARA-III Reactor building (ARA-608) Sections. Show high-bay section, heater stack, and depth of reactor, piping, and heater pits. Aerojet-general 880-area/GCRE-608-A-3. Date: February 1958. Ineel index code no. 063-0608-00-013-102613. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
MTR WING, TRA604. BASEMENT FLOOR PLAN. FIREPROOF RECORD ROOM BELOW ...
MTR WING, TRA-604. BASEMENT FLOOR PLAN. FIRE-PROOF RECORD ROOM BELOW COUNTING ROOM. HEATING AND COOLING EQUIPMENT. UNSPECIFIED EXPANSION AREA ALONG WEST WALL. BLAW-KNOX 3150-4-1, 7/1950. INL INDEX NO. 531-0604-00-098-100007, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
79. ARAIII. Early construction view of GCRE reactor building (ARA608) ...
79. ARA-III. Early construction view of GCRE reactor building (ARA-608) showing deep excavation, reinforcing steel, and forms for concrete placement for reactor and other pits. Camera facing southeast. July 22, 1958. Ineel photo no. 58-3466. Photographer: Ken Mansfield. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
138. ARAII Building ARA606 floor plan for remodel as Inel ...
138. ARA-II Building ARA-606 floor plan for remodel as Inel Welding Laboratory. Shows room divisions and welding stations to be installed. Aerojet Nuclear Company 1375-ARA-II-606-E-2. Date: June 1976. Ineel index code no. 070-0606-10-400-156552. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
PBF Control Building (PER619) floor plan and elevations. Room numbers ...
PBF Control Building (PER-619) floor plan and elevations. Room numbers and functions. Roof plans for "high" roof and rest of roof. Ebasco Services 1205-PER/PER 619-A-1. Date: July 1965. INEEL index no. 760-0619-00-205-123022 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. CAMERA LOOKING EAST AND TO WEST ...
PROCESS WATER BUILDING, TRA-605. CAMERA LOOKING EAST AND TO WEST WALL NOW ENCLOSING FLASH EVAPORATORS. PIPES IN FOREGROUND WILL CARRY DEMINERALIZED COOLING WATER TO AND FROM THE MTR. INL NEGATIVE NO. 2937. Unknown Photographer, 7/30/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
WATER PUMP HOUSE, TRA619, PUMP INSTALLATION. CAMERA FACING NORTHEAST CORNER. ...
WATER PUMP HOUSE, TRA-619, PUMP INSTALLATION. CAMERA FACING NORTHEAST CORNER. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON THE ORIGINAL NEGATIVE. INL NEGATIVE NO. 3998. Unknown Photographer, 12/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
HORIZONTAL BEAM HOLE NO. 3. PLUG AND RADIATION DOOR HAVE ...
HORIZONTAL BEAM HOLE NO. 3. PLUG AND RADIATION DOOR HAVE BEEN REMOVED. EXPERIMENTAL APPARATUS WAS INSERTED INTO THE HOLE. NOTE VALVE CUBICLES NEAR FLOOR ON EACH SIDE OF HB-3. INL NEGATIVE NO. 3471. Unknown Photographer, 10/12/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. ON GROUND FLOOR. WITH OUTER THERMAL RING IN ...
ETR, TRA-642. ON GROUND FLOOR. WITH OUTER THERMAL RING IN PLACE AND CONDUIT PRESERVED, HIGH-DENSITY CONCRETE IS PLACED BETWEEN THE THERMAL RING AND THE OUTER REACTOR FORM. INL NEGATIVE NO. 56-2400. Jack L. Anderson, Photographer, 6/10/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
FAST CHOPPER BUILDING, TRA665. DETAIL SHOWS UPPER AND LOWER LEVEL ...
FAST CHOPPER BUILDING, TRA-665. DETAIL SHOWS UPPER AND LOWER LEVEL WALLS OF DIFFERING MATERIALS. NOTE DOORWAY TO MTR TO RIGHT OF CHOPPER BUILDING'S CLIPPED CORNER. CAMERA FACING WEST. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
LPT. Low power test (TAN640) interior. Basement level. Camera facing ...
LPT. Low power test (TAN-640) interior. Basement level. Camera facing north. Cable trays and conduit cross tunnel between critical experiment cell and critical experiment control room. Construction 93% complete. Photographer: Jack L. Anderson. Date: October 23, 1957. INEEL negative no. 57-5339 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Smirnov, A. Yu; Mustafin, A. R.; Nevinitsa, V. A.; Sulaberidze, G. A.; Dudnikov, A. A.; Gusev, V. E.
2017-01-01
The effect of the uncertainties of the isotopic composition of the reprocessed uranium on its enrichment process in gas centrifuge cascades while diluting it by adding low-enriched uranium (LEU) and waste uranium. It is shown that changing the content of 232U and 236U isotopes in the initial reprocessed uranium within 15% (rel.) can significantly change natural uranium consumption and separative work (up to 2-3%). However, even in case of increase of these parameters is possible to find the ratio of diluents, where the cascade with three feed flows (depleted uranium, LEU and reprocessed uranium) will be more effective than ordinary separation cascade with one feed point for producing LEU from natural uranium.
Wang, Yongwei; Pan, Yi; Zheng, Zhaohui; Ding, Xiaobin
2018-04-20
Degradable shape memory polymers (SMPs), especially for polyurethane-based SMPs, have shown great potential for biomedical applications. How to reasonably fabricate SMPs with the ideal combination of degradability, shape reconfigurability, and reprocessability is a critical issue and remains a challenge for medical disposable materials. Herein, a shape memory poly(urethane-urea) with synergetic triple dynamic covalent bonds is reported via embedding polycaprolactone unit into poly(urethane-urea) with the hindered urea dynamic bond. The single polymer network is biodegradable, thermadapt, and reprocessable, without sacrificing the outstanding shape memory performance. Such a shape memory network with plasticity and reprocessability is expected to have significant and positive impact on the medical device industry. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
2011-01-01
Background Reprocessing of endoscopes generally requires labour-intensive manual cleaning followed by high-level disinfection in an automated endoscope reprocessor (AER). EVOTECH Endoscope Cleaner and Reprocessor (ECR) is approved for fully automated cleaning and disinfection whereas AERs require manual cleaning prior to the high-level disinfection procedure. The purpose of this economic evaluation was to determine the cost-efficiency of the ECR versus AER methods of endoscopy reprocessing in an actual practice setting. Methods A time and motion study was conducted at a Canadian hospital to collect data on the personnel resources and consumable supplies costs associated with the use of EVOTECH ECR versus manual cleaning followed by AER with Medivators DSD-201. Reprocessing of all endoscopes was observed and timed for both reprocessor types over three days. Laboratory staff members were interviewed regarding the consumption and cost of all disposable supplies and equipment. Exact Wilcoxon rank sum test was used for assessing differences in total cycle reprocessing time. Results Endoscope reprocessing was significantly shorter with the ECR than with manual cleaning followed by AER. The differences in median time were 12.46 minutes per colonoscope (p < 0.0001), 6.31 minutes per gastroscope (p < 0.0001), and 5.66 minutes per bronchoscope (p = 0.0040). Almost 2 hours of direct labour time was saved daily with the ECR. The total per cycle cost of consumables and labour for maintenance was slightly higher for EVOTECH ECR versus manual cleaning followed by AER ($8.91 versus $8.31, respectively). Including the cost of direct labour time consumed in reprocessing scopes, the per cycle and annual costs of using the EVOTECH ECR was less than the cost of manual cleaning followed by AER disinfection ($11.50 versus $11.88). Conclusions The EVOTECH ECR was more efficient and less costly to use for the reprocessing of endoscopes than manual cleaning followed by AER disinfection. Although the cost of consumable supplies required to reprocess endoscopes with EVOTECH ECR was slightly higher, the value of the labour time saved with EVOTECH ECR more than offset the additional consumables cost. The increased efficiency with EVOTECH ECR could lead to even further cost-savings by shifting endoscopy laboratory personnel responsibilities but further study is required. PMID:21967345
Forte, Lindy; Shum, Cynthia
2011-10-03
Reprocessing of endoscopes generally requires labour-intensive manual cleaning followed by high-level disinfection in an automated endoscope reprocessor (AER). EVOTECH Endoscope Cleaner and Reprocessor (ECR) is approved for fully automated cleaning and disinfection whereas AERs require manual cleaning prior to the high-level disinfection procedure. The purpose of this economic evaluation was to determine the cost-efficiency of the ECR versus AER methods of endoscopy reprocessing in an actual practice setting. A time and motion study was conducted at a Canadian hospital to collect data on the personnel resources and consumable supplies costs associated with the use of EVOTECH ECR versus manual cleaning followed by AER with Medivators DSD-201. Reprocessing of all endoscopes was observed and timed for both reprocessor types over three days. Laboratory staff members were interviewed regarding the consumption and cost of all disposable supplies and equipment. Exact Wilcoxon rank sum test was used for assessing differences in total cycle reprocessing time. Endoscope reprocessing was significantly shorter with the ECR than with manual cleaning followed by AER. The differences in median time were 12.46 minutes per colonoscope (p < 0.0001), 6.31 minutes per gastroscope (p < 0.0001), and 5.66 minutes per bronchoscope (p = 0.0040). Almost 2 hours of direct labour time was saved daily with the ECR. The total per cycle cost of consumables and labour for maintenance was slightly higher for EVOTECH ECR versus manual cleaning followed by AER ($8.91 versus $8.31, respectively). Including the cost of direct labour time consumed in reprocessing scopes, the per cycle and annual costs of using the EVOTECH ECR was less than the cost of manual cleaning followed by AER disinfection ($11.50 versus $11.88). The EVOTECH ECR was more efficient and less costly to use for the reprocessing of endoscopes than manual cleaning followed by AER disinfection. Although the cost of consumable supplies required to reprocess endoscopes with EVOTECH ECR was slightly higher, the value of the labour time saved with EVOTECH ECR more than offset the additional consumables cost. The increased efficiency with EVOTECH ECR could lead to even further cost-savings by shifting endoscopy laboratory personnel responsibilities but further study is required.
Evaluation of Methods for Decladding LWR Fuel for a Pyroprocessing-Based Reprocessing Plant
1992-10-01
oAD-A275 326 ORN.rFM-1121o04 OAK RIDGE NATIONAL LABORATORY Evaluation of Methods for Decladding _LWR Fuel for a Pyroprocessing -Based Reprocessing...Dist. Category UC-526 EVALUATION OF METHODS FOR DECLADDING LWR FUEL FOR A PYROPROCESSING -BASED REPROCESSING PLANT W. D. Bond J. C. Mailen G. E...decladding technologies has been performed to identify candidate decladding processes suitable for LWR fuel and compatible with downstream pyroprocesses
2009-01-01
Background The surface of polymeric tracheotomy tubes is a favourable environment for biofilm formation and therefore represents a potential risk factor for the development of pneumonia after tracheotomy. The aim of this in-vitro study was to develop octenidine-dihydrochloride (OCT) coated polymer tracheotomy tubes and investigate any effects on Staphylococcus (S.) aureus and Pseudomonas (P.) aeruginosa colonization. Additionally the resistance of the OCT coating was tested using reprocessing procedures like brushing, rinsing and disinfection with glutaraldehyde Results Contamination with S. aureus: Before any reprocessing, OCT coated tracheotomy tubes were colonized with 103 cfu/ml and uncoated tracheotomy tubes with 105 cfu/ml (P = 0.045). After reprocessing, no differences in bacterial concentration between modified and conventional tubes were observed. Contamination with P. aeruginosa: Before reprocessing, OCT coated tubes were colonized with 106 cfu/ml and uncoated tubes with 107 cfu/ml (P = 0.006). After reprocessing, no significant differences were observed. Conclusion OCT coating initially inhibits S. aureus and P. aeruginosa colonisation on tracheotomy tubes. This effect, however, vanishes quickly after reprocessing of the tubes due to poor adhesive properties of the antimicrobial compound. Despite the known antimicrobial effect of OCT, its use for antimicrobial coating of tracheotomy tubes is limited unless methods are developed to allow sustained attachment to the tube. PMID:19630994
Trentini, Cristina; Pagani, Marco; Fania, Piercarlo; Speranza, Anna Maria; Nicolais, Giampaolo; Sibilia, Alessandra; Inguscio, Lucio; Verardo, Anna Rita; Fernandez, Isabel; Ammaniti, Massimo
2015-01-01
Eye Movement Desensitization and Reprocessing (EMDR) therapy has been proven efficacious in restoring affective regulation in post-traumatic stress disorder (PTSD) patients. However, its effectiveness on emotion processing in children with complex trauma has yet to be explored. High density electroencephalography (hdEEG) was used to investigate the effects of EMDR on brain responses to adults’ emotions on children with histories of early maltreatment. Ten school-aged children were examined before (T0) and within one month after the conclusion of EMDR (T1). hdEEGs were recorded while children passively viewed angry, afraid, happy, and neutral faces. Clinical scales were administered at the same time. Correlation analyses were performed to detect brain regions whose activity was linked to children’s traumatic symptom-related and emotional-adaptive problem scores. In all four conditions, hdEEG showed similar significantly higher activity on the right medial prefrontal and fronto-temporal limbic regions at T0, shifting toward the left medial and superior temporal regions at T1. Moreover, significant correlations were found between clinical scales and the same regions whose activity significantly differed between pre- and post-treatment. These preliminary results demonstrate that, after EMDR, children suffering from complex trauma show increased activity in areas implicated in high-order cognitive processing when passively viewing pictures of emotional expressions. These changes are associated with the decrease of depressive and traumatic symptoms, and with the improvement of emotional-adaptive functioning over time. PMID:26594183
Availability analysis of an HTGR fuel recycle facility. Summary report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharmahd, J.N.
1979-11-01
An availability analysis of reprocessing systems in a high-temperature gas-cooled reactor (HTGR) fuel recycle facility was completed. This report summarizes work done to date to define and determine reprocessing system availability for a previously planned HTGR recycle reference facility (HRRF). Schedules and procedures for further work during reprocessing development and for HRRF design and construction are proposed in this report. Probable failure rates, transfer times, and repair times are estimated for major system components. Unscheduled down times are summarized.