Sample records for required dose monitoring

  1. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...

  2. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...

  3. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...

  4. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...

  5. 10 CFR 20.1502 - Conditions requiring individual monitoring of external and internal occupational dose.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... internal occupational dose. 20.1502 Section 20.1502 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Surveys and Monitoring § 20.1502 Conditions requiring individual monitoring of external and internal occupational dose. Each licensee shall monitor exposures to radiation and radioactive...

  6. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  7. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  8. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  9. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  10. 10 CFR 835.702 - Individual monitoring records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... emergency exposures. (b) Recording of the non-uniform equivalent dose to the skin is not required if the... internal dose (committed effective dose or committed equivalent dose) is not required for any monitoring...: (i) The effective dose from external sources of radiation (equivalent dose to the whole body may be...

  11. Current methods of monitoring radiation exposure from CT.

    PubMed

    Talati, Ronak K; Dunkin, Jared; Parikh, Shrujal; Moore, William H

    2013-09-01

    Increased public and regulatory scrutiny of imaging-related radiation exposure requires familiarity with current dose-monitoring techniques and best practices. CT-related ionizing radiation exposure has been cited as the largest and fastest growing source of population-wide iatrogenic ionizing radiation exposure. Upcoming federal regulations require imaging centers to familiarize themselves with available dose-monitoring techniques and implement comprehensive strategies to track patient dose, with particular emphasis on CT. Because of institution-specific and vendor-specific technologies, there are significant barriers to adoption and implementation. In this article, the authors outline the core components of a universal dose-monitoring strategy and detail a few of the many available commercial platforms. In addition, the authors introduce a cloud-based hybrid model dose-tracking system with the goal of rapid implementation, multicenter scalability, real-time dose feedback for technologists, cumulative dose monitoring, and optional dose communication to patients and into the record; doing so results in improved patient loyalty, referring physician satisfaction, and opportunity for repeat business. Copyright © 2013 American College of Radiology. All rights reserved.

  12. Design and operation of internal dosimetry programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaBone, T.R.

    1991-01-01

    The proposed revision to USNRC 10 CFR 20 and the USDOE Order 5480.11 require intakes of radioactive material to be evaluated. Radiation dose limits are based on the sum of effective dose equivalent from intakes and the whole body dose from external sources. These significant changes in the regulations will require, at a minimum, a complete review of personnel monitoring programs to determine their adequacy. In this session we will review a systematic method of designing a routine personnel monitoring program that will comply with the requirements of the new regulations. Specific questions discussed are: (a) What are the goalsmore » and objectives of a routine personnel monitoring program (b) When is a routine personnel monitoring program required (c) What are the required capabilities of the routine personnel monitoring program (d) What should be done with the information generated in a personnel monitoring program Specific recommendations and interpretations are given in the session. 5 refs., 3 figs., 33 tabs.« less

  13. Application of ISO standard 27048: dose assessment for the monitoring of workers for internal radiation exposure.

    PubMed

    Henrichs, K

    2011-03-01

    Besides ongoing developments in the dosimetry of incorporated radionuclides, there are various efforts to improve the monitoring of workers for potential or real intakes of radionuclides. The disillusioning experience with numerous intercomparison projects identified substantial differences between national regulations, concepts, applied programmes and methods, and dose assessment procedures. Measured activities were not directly comparable because of significant differences between measuring frequencies and methods, but also results of case studies for dose assessments revealed differences of orders of magnitude. Besides the general common interest in reliable monitoring results, at least the cross-border activities of workers (e.g. nuclear power plant services) require consistent approaches and comparable results. The International Standardization Organization therefore initiated projects to standardise programmes for the monitoring of workers, the requirements for measuring laboratories and the processes for the quantitative evaluation of monitoring results in terms of internal assessed doses. The strength of the concepts applied by the international working group consists in a unified approach defining the requirements, databases and processes. This paper is intended to give a short introduction into the standardization project followed by a more detailed description of the dose assessment standard, which will be published in the very near future.

  14. Techniques for Monitoring Drug Efficacy.

    PubMed

    Visser, Marike

    2018-05-01

    The efficacy of drugs can vary greatly between species and individuals. Establishing efficacious drug doses for a species requires integration of population pharmacokinetic and pharmacodynamic data into a dose-response curve. Unfortunately, these data sets are rarely available for exotic species. The use of alternative monitoring techniques is required to determine drug efficacy and safety. This article discusses methods to integrate efficacy monitoring into clinical practice, including the use of diagnostic testing and therapeutic drug monitoring. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Using Six Sigma to improve once daily gentamicin dosing and therapeutic drug monitoring performance.

    PubMed

    Egan, Sean; Murphy, Philip G; Fennell, Jerome P; Kelly, Sinead; Hickey, Mary; McLean, Carolyn; Pate, Muriel; Kirke, Ciara; Whiriskey, Annette; Wall, Niall; McCullagh, Eddie; Murphy, Joan; Delaney, Tim

    2012-12-01

    Safe, effective therapy with the antimicrobial gentamicin requires good practice in dose selection and monitoring of serum levels. Suboptimal therapy occurs with breakdown in the process of drug dosing, serum blood sampling, laboratory processing and level interpretation. Unintentional underdosing may result. This improvement effort aimed to optimise this process in an academic teaching hospital using Six Sigma process improvement methodology. A multidisciplinary project team was formed. Process measures considered critical to quality were defined, and baseline practice was examined through process mapping and audit. Root cause analysis informed improvement measures. These included a new dosing and monitoring schedule, and standardised assay sampling and drug administration timing which maximised local capabilities. Three iterations of the improvement cycle were conducted over a 24-month period. The attainment of serum level sampling in the required time window improved by 85% (p≤0.0001). A 66% improvement in accuracy of dosing was observed (p≤0.0001). Unnecessary dose omission while awaiting level results and inadvertent disruption to therapy due to dosing and monitoring process breakdown were eliminated. Average daily dose administered increased from 3.39 mg/kg to 4.78 mg/kg/day. Using Six Sigma methodology enhanced gentamicin usage process performance. Local process related factors may adversely affect adherence to practice guidelines for gentamicin, a drug which is complex to use. It is vital to adapt dosing guidance and monitoring requirements so that they are capable of being implemented in the clinical environment as a matter of routine. Improvement may be achieved through a structured localised approach with multidisciplinary stakeholder involvement.

  16. Dose Monitoring in Radiology Departments: Status Quo and Future Perspectives.

    PubMed

    Boos, J; Meineke, A; Bethge, O T; Antoch, G; Kröpil, P

    2016-05-01

    The number of computed tomography examinations has continuously increased over the last decades and accounts for a major part of the collective radiation dose from medical investigations. For purposes of quality assurance in modern radiology a systematic monitoring and analysis of dose related data from radiological examinations is mandatory. Various ways of collecting dose data are available today, for example the Digital Imaging and Communication in Medicine - Structured Report (DICOM-SR), optical character recognition and DICOM-modality performed procedure steps (MPPS). The DICOM-SR is part of the DICOM-standard and provides the DICOM-Radiation Dose Structured Report, which is an easily applicable and comprehensive solution to collect radiation dose parameters. This standard simplifies the process of data collection and enables comprehensive dose monitoring. Various commercial dose monitoring software devices with varying characteristics are available today. In this article, we discuss legal obligations, various ways to monitor dose data, current dose monitoring software solutions and future perspectives in regard to the EU Council Directive 2013/59/EURATOM. • Automated, systematic dose monitoring is an important element in quality assurance of radiology departments. • DICOM-RDSR-capable CT scanners facilitate the monitoring of dose data. • A variety of commercial and non-commercial dose monitoring software tools are available today. • Successful dose monitoring requires comprehensive infrastructure for monitoring, analysing and optimizing radiation exposure. Citation Format: • Boos J, Meineke A, Bethge OT et al. Dose Monitoring in Radiology Departments: Status Quo and Future Perspectives. Fortschr Röntgenstr 2016; 188: 443 - 450. © Georg Thieme Verlag KG Stuttgart · New York.

  17. EYE LENS DOSIMETRY FOR FLUOROSCOPICALLY GUIDED CLINICAL PROCEDURES: PRACTICAL APPROACHES TO PROTECTION AND DOSE MONITORING.

    PubMed

    Martin, Colin J

    2016-06-01

    Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Continuing education: online monitoring of haemodialysis dose.

    PubMed

    Vartia, Aarne

    2018-01-25

    Kt/V urea reflects the efficacy of haemodialysis scaled to patient size (urea distribution volume). The guidelines recommend monthly Kt/V measurements based on blood samples. Modern haemodialysis machines are equipped with accessories monitoring the dose online at every session without extra costs, blood samples and computers. To describe the principles, devices, benefits and shortcomings of online monitoring of haemodialysis dose. A critical literature overview and discussion. UV absorbance methods measure Kt/V, ionic dialysance Kt (product of clearance and treatment time; cleared volume without scaling). Both are easy and useful methods, but comparison is difficult due to problems in scaling of the dialysis dose to the patient's size. The best dose estimation method is the one which predicts the quality of life and survival most accurately. There is some evidence on the predictive value of ionic dialysance Kt, but more documentation is required on the UV method. Online monitoring is a useful tool in everyday quality assurance, but blood samples are still required for more accurate kinetic modelling. After reading this article the reader should be able to: Understand the elements of the Kt/V equation for dialysis dose. Compare and contrast different methods of measurement of dialysis dose. Reflect on the importance of adequate dialysis dose for patient survival and life quality. © 2018 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  19. SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, JM; Samei, E; Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, NC

    2016-06-15

    Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistencymore » and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.« less

  20. Preliminary analysis of the implications of natural radiations on geostationary operations

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; Denn, F. M.

    1976-01-01

    The natural radiations present at geostationary orbit are discussed. Low-level galactic cosmic rays are important for careers spending a year or more at geostationary altitude. Trapped radiation will on occasion require interruption of extravehicular activity (EVA). The spacesuit shield requirements are strongly affected by the number of interruptions allowed. EVA cannot proceed during a large solar event and maximum allowable doses are exceeded in a few hours unless a heavily shielded area is provided. A shelter of 10 g/sq cm with personal shielding for the eyes and testes would contain exposure to within the presently accepted exposure constraints. Since radiation levels can increase unexpectedly to serious levels, an onboard radiation monitoring system with rate and integration capabilities is required for both surface-dose and depth-dose monitoring.

  1. Treatment and therapeutic monitoring of canine hypothyroidism.

    PubMed

    Dixon, R M; Reid, S W J; Mooney, C T

    2002-08-01

    Thirty-one dogs with spontaneous hypothyroidism were treated with thyroid hormone replacement therapy (THRT) and monitored for approximately three months. Good clinical and laboratory control was ultimately achieved in all cases with a mean L-thyroxine (T4) dose of 0.026 mg/kg administered once daily. There was a significant increase and decrease in circulating total T4 and canine thyroid stimulating hormone (cTSH) concentrations, respectively, after starting THRT. After commencing treatment, 11 cases subsequently required an increase and three cases required a decrease in dose to achieve optimal clinical control. Median (semi interquartile range [SIR]) circulating six-hour post-pill total T4 (53.6 [27.91 nmol/litre) and cTSH (0.03 [0] microg/litre) concentrations were significantly increased and decreased, respectively, in treated dogs that did not require a dose change; corresponding values in treated dogs in which an increase in dose was required were 29.3 (12.7) nmol/litre and 0.15 (0.62) microg/litre, respectively. However, circulating cTSH measurement was of limited value in assessing therapeutic control because, although increased values were associated with inadequate therapy, reference range cTSH values were common in inadequately treated dogs. Lethargy and mental demeanour were typically the first clinical signs to improve, with significant bodyweight reduction occurring within two weeks of commencing THRT. Routine clinicopathological monitoring was of value in confirming a general metabolic response to THRT, but was of limited value in accurately monitoring cases or tailoring therapy in individual cases.

  2. EMP Attachment 3 DOE-SC PNNL Site Dose Assessment Guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Sandra F.

    2011-12-21

    This Dose Assessment Guidance (DAG) describes methods to use to determine the Maximally-Exposed Individual (MEI) location and to estimate dose impact to that individual under the U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from PNNL Site operations. This document is an attachment to the Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP) and describes dose assessment guidance for radiological air emissions. The impact of radiological air emissions from the U.S. Department of Energy Office ofmore » Science (DOE-SC) PNNL Site is indicated by dose estimates to a maximally exposed member of the public, referred to as the maximally exposed individual (MEI). Reporting requirements associated with dose to members of the public from radiological air emissions are in 40 CFR Part 61.94, WAC 246-247-080, and DOE Order 458.1. The DOE Order and state standards for dose from radioactive air emissions are consistent with U.S. Environmental Protection Agency (EPA) dose standards in 40 CFR 61.92 (i.e., 10 mrem/yr to a MEI). Despite the fact that the current Contract Requirements Document (CRD) for the DOE-SC PNNL Site operations does not include the requirement to meet DOE CRD 458.1, paragraph 2.b, public dose limits, the DOE dose limits would be met when EPA limits are met.« less

  3. The design of Radiation Accident Registry.

    PubMed

    Chen, Jing; Seely, Bob; Bergman, Lauren; Moir, Deborah

    2011-03-01

    In order to provide effective monitoring and follow-up on the health effects of individuals accidentally exposed to ionising radiation, a Radiation Accident Registry (RAR) has been designed and constructed as an extension to the existing National Dose Registry (NDR). The RAR has basic functions of recording, monitoring and reporting. This type of registry is able to assist responders in preparing for and managing situations during radiological events and in providing effective follow-up on the long-term health effects of persons exposed to ionising radiation. It is especially important to register radiation-exposed people in vulnerable population groups, such as children and pregnant women, to ensure proper long-term health care and protection. Even though radiation accidents are rare, a registry prepared for such accidents could involve a large population and, in some cases, require lifetime monitoring for individuals. One of the most challenging tasks associated with RAR is the assessment of radiation dose resulting from accidents. In some cases, the assessment of radiation doses to individuals could be a process requiring the involvement of various methods. The development of fast and accurate dose assessment tools will remain a long-term challenge associated with the RAR. To meet this challenge, further research activities in radiation dosimetry for individual monitoring are needed.

  4. Monitoring Effective Doses Received By Air Crews With A Space Weather Application

    NASA Astrophysics Data System (ADS)

    Lantos, P.

    To fulfil new requirements of the European Community concerning monitoring of effective doses received by air crews, the French Aviation Authority has developed an operational system called Sievert. The SIEVERT system is analysed as an exam- ple of Space Weather application. One of its characteristics is to calculate the dose received on-board each flight on the basis of the specific and detailled flight given by companies. Operational models will be used. As input to the models, the system needs monitoring of galactic cosmic rays and of solar flare particles. The French neu- tron monitors located in Kerguelen Islands (South Indian Ocean) and Terre Adélie (Antarctica) will be used for this purpose. Particular attention will be devoted to evo- lution of the system in conjunction with new measurements available in the frame of a permanent validation process.

  5. SU-E-T-619: Planning 131I Thyroid Treatments for Patients Requiring Hemodialysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stroud, D

    Purpose: Treatment of 131I thyroid cancer patients who also require regular hemodialysis (HD) treatments requires consideration of the administered activity and the HD schedule. In this work the red bone marrow is considered the dose limiting organ and the treatment plan optimized the HD schedule with the amount of radioactivity administered. Methods: The ‘Safe’ dose was considered to be 2 Gy (200 rad) to the red bone marrow.1 131Iodine doses of 50 mCi to 100 mCi were modeled and found to require a range of HD schedules. In order to achieve the safe dose to the red marrow, more aggressivemore » HD schedules are required. 100 mCi required an aggressive HD treatment of every 24 hours for at least one week to achieve the ‘safe’ dose and an exposure appropriate for release from the hospital. A more normal schedule of HD beginning at 18 hours then every 48 hours allowed for up to 60 mCi administered dose allowed for a safe dose and expected release after less than one week.2In addition room was equipped with video cameras cameras for monitoring the patient and their vital signs from an adjacent room during HD. In this way the dialysis nurses were able to monitor the patient closely from an adjoining room. Results: Two HD patients were administered adjusted doses of about 50 mCi. The medical and nursing staff were exposed to no more than 4 mR for the entire treatment. The residual Iodine in the patient appeared to be normal after 4 to 6 days when the patient was released. Conclusion: With careful treatment planning 131Iodine treatments can be performed safely for patients needing HD and treatments appear to be as effective as those for patients with normal renal function.« less

  6. Occupational exposure assessment: Practices in Malaysian nuclear agency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarowi, S. Muhd, E-mail: suzie@nuclearmalaysia.gov.my; Ramli, S. A.; Kontol, K. Mohamad

    Malaysian Nuclear Agency (Nuclear Malaysia) is the leading agency in introducing and promoting the application of nuclear science technology in Malaysia. The agency provides major nuclear facilities purposely for research and commercialisation such as reactor, irradiation plants and radioisotope production laboratory. When dealing with ionizing radiation, there is an obligatory requirement to monitor and assess the radiation exposure to the workers. The personal dose of radiation workers were monitored monthly by assessing their Thermoluminescence Dosimeter (TLD) dose reading. This paper will discuss the current practice in managing, assessing, record keeping and reporting of the occupational exposure in Nuclear Malaysia includingmore » the Health Physic Group roles and challenges. The statistics on occupational radiation exposure of monitored workers working in different fields in Nuclear Malaysia from 2011 - 2013 will also be presented. The results show that the null hypothesis (H{sub 0}) was accepted which the means of every populations are all equal or not differ significantly. This hypothesis states that the dose exposure received by the radiation workers in Nuclear Malaysia is similar and there were no significant changes from 2011 to 2013. The radiation monitoring programme correlate with the requirement of our national law, the Atomic Energy Licensing Act 1984 (Act 304)« less

  7. Occupational exposure assessment: Practices in Malaysian nuclear agency

    NASA Astrophysics Data System (ADS)

    Sarowi, S. Muhd; Ramli, S. A.; Kontol, K. Mohamad; Rahman, N. A. H. Abd.

    2016-01-01

    Malaysian Nuclear Agency (Nuclear Malaysia) is the leading agency in introducing and promoting the application of nuclear science technology in Malaysia. The agency provides major nuclear facilities purposely for research and commercialisation such as reactor, irradiation plants and radioisotope production laboratory. When dealing with ionizing radiation, there is an obligatory requirement to monitor and assess the radiation exposure to the workers. The personal dose of radiation workers were monitored monthly by assessing their Thermoluminescence Dosimeter (TLD) dose reading. This paper will discuss the current practice in managing, assessing, record keeping and reporting of the occupational exposure in Nuclear Malaysia including the Health Physic Group roles and challenges. The statistics on occupational radiation exposure of monitored workers working in different fields in Nuclear Malaysia from 2011 - 2013 will also be presented. The results show that the null hypothesis (H₀) was accepted which the means of every populations are all equal or not differ significantly. This hypothesis states that the dose exposure received by the radiation workers in Nuclear Malaysia is similar and there were no significant changes from 2011 to 2013. The radiation monitoring programme correlate with the requirement of our national law, the Atomic Energy Licensing Act 1984 (Act 304).

  8. Hanford Internal Dosimetry Project manual. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, E.H.; Bihl, D.E.; MacLellan, J.A.

    1994-07-01

    This document describes the Hanford Internal Dosimetry Project, as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy and its Hanford contractors. Project services include administrating the bioassay monitoring program, evaluating and documenting assessment of potential intakes and internal dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. Specific chapters deal with the following subjects: practices of the project, including interpretation of applicable DOE Orders, regulations, andmore » guidance into criteria for assessment, documentation, and reporting of doses; assessment of internal dose, including summary explanations of when and how assessments are performed; recording and reporting practices for internal dose; selection of workers for bioassay monitoring and establishment of type and frequency of bioassay measurements; capability and scheduling of bioassay monitoring services; recommended dosimetry response to potential internal exposure incidents; quality control and quality assurance provisions of the program.« less

  9. Radiation monitoring in interventional cardiology: a requirement

    NASA Astrophysics Data System (ADS)

    Rivera, T.; Uruchurtu, E. S.

    2017-01-01

    The increasing of procedures using fluoroscopy in interventional cardiology procedures may increase medical and patients to levels of radiation that manifest in unintended outcomes. Such outcomes may include skin injury and cancer. The cardiologists and other staff members in interventional cardiology are usually working close to the area under examination and they receive the dose primarily from scattered radiation from the patient. Mexico does not have a formal policy for monitoring and recording the radiation dose delivered in hemodynamic establishments. Deterministic risk management can be improved by monitoring the radiation delivered from X-ray devices. The objective of this paper is to provide cardiologist, techniques, nurses, and all medical staff an information on DR levels, about X-ray risks and a simple a reliable method to control cumulative dose.

  10. Pediatric Fluid and Electrolyte Therapy

    PubMed Central

    Meyers, Rachel S.

    2009-01-01

    Managing fluids and electrolytes in children is an important skill for pharmacists, who can play an important role in monitoring therapy. Fluid therapy is divided into maintenance, deficit, and replacement requirements. The Holliday-Segar equation remains the standard method for calculating maintenance fluid requirements. Accounting for deficits when determining the fluid infusion rate is an important factor in treating dehydrated patients; deficit fluid is generally administered over the first 24 hours of hospitalization. Maintenance electrolyte requirements must be taken into account, with particular attention paid to sodium requirements, as recent evidence suggests that sodium needs in hospitalized children are higher than originally thought. Fluid therapy can also have an impact on drug therapy. Hydration status can affect the dose needed to achieve therapeutic concentrations, and dehydrated patients may be at risk for toxicity if standard doses of drugs with high volumes of distribution are used. Monitoring fluid and electrolyte therapy is an important role of the pediatric pharmacist. PMID:23055905

  11. Clinical Application and Pharmacodynamic Monitoring of Apixaban in a Patient with End-Stage Renal Disease Requiring Chronic Hemodialysis.

    PubMed

    Kufel, Wesley D; Zayac, Adam S; Lehmann, David F; Miller, Christopher D

    2016-11-01

    Despite prescribing guidance, limited data exist to describe the use of apixaban in patients with end-stage renal disease (ESRD) requiring hemodialysis (HD). Current apixaban dosing recommendations for this patient population are based largely on a single-dose pharmacokinetic study of eight patients. We describe the clinical application and pharmacodynamic monitoring of apixaban in a 62-year-old 156-kg African-American woman with nonvalvular atrial fibrillation and ESRD requiring hemodialysis who developed calciphylaxis while receiving warfarin therapy. Based on a multidisciplinary clinical judgment decision due to concern for drug accumulation after multiple doses in patients with ESRD receiving HD, she was anticoagulated with apixaban 2.5 mg twice/day, as opposed to 5 mg twice/day as recommended by the package insert. Antifactor Xa monitoring was used, and resultant peak and trough apixaban concentrations were above the upper limit of detection for our clinical laboratory (more than 2.00 IU/ml). On day 7 of her hospitalization, the patient developed gastrointestinal bleeding, and apixaban was discontinued; no further clinical signs of bleeding occurred during her subsequent hospitalization course. Use of the Naranjo Adverse Drug Reaction Probability Scale indicated a probable relationship (score of 6) between apixaban exposure and the manifestation of gastrointestinal bleeding. The patient ultimately died 44 days after the acute bleeding event; however, coagulation concerns were not implicated in the patient's death. To our knowledge, this is the first case report that describes apixaban use and associated antifactor Xa monitoring in a patient with ESRD receiving HD, and it provides concern for current apixaban dosing recommendations in this patient population. Further pharmacokinetic and clinical data are likely necessary to better characterize apixaban use in these patients to optimize safety and efficacy. © 2016 Pharmacotherapy Publications, Inc.

  12. Challenges of stroke prevention in patients with atrial fibrillation in clinical practice.

    PubMed

    Hobbs, F D Richard; Leach, I

    2011-09-01

    Strokes and transient ischaemic attacks in patients with atrial fibrillation (AF) can be largely prevented. Risk stratification and appropriate prophylactic regimens help to alleviate the burden of AF-related thromboembolism. Guidelines recommend routine anticoagulation with oral vitamin K antagonists (VKAs) for patients at moderate-to-high risk of stroke, and acetylsalicylic acid (ASA) for those at low risk of stroke. ASA is less effective at reducing the risk of stroke than VKAs; however, ASA does not require monitoring or dose adjustment. Trials of anticoagulants show consistent benefits of oral VKAs for primary and secondary stroke prevention in patients with AF. Nevertheless, VKAs do require frequent coagulation monitoring and dose adjustment because of their variable dose-response profile, narrow therapeutic window, increased risk for bleeding complications and numerous food and drug interactions. This review aims to provide an overview of the clinical challenges of anticoagulant therapy for the prevention of stroke in patients with AF.

  13. Phantom-derived estimation of effective dose equivalent from X rays with and without a lead apron.

    PubMed

    Mateya, C F; Claycamp, H G

    1997-06-01

    Organ dose equivalents were measured in a humanoid phantom in order to estimate effective dose equivalent (H(E)) and effective dose (E) from low-energy x rays and in the presence or absence of a protective lead apron. Plane-parallel irradiation conditions were approximated using direct x-ray beams of 76 and 104 kVp and resulting dosimetry data was adjusted to model exposures conditions in fluoroscopy settings. Values of H(E) and E estimated under-shielded conditions were compared to the results of several recent studies that used combinations of measured and calculated dosimetry to model exposures to radiologists. While the estimates of H(E) and E without the lead apron were within 0.2 to 20% of expected values, estimates based on personal monitors worn at the (phantom) waist (underneath the apron) underestimated either H(E) or E while monitors placed at the neck (above the apron) significantly overestimated both quantities. Also, the experimentally determined H(E) and E were 1.4 to 3.3 times greater than might be estimated using recently reported "two-monitor" algorithms for the estimation of effective dose quantities. The results suggest that accurate estimation of either H(E) or E from personal monitors under conditions of partial body exposures remains problematic and is likely to require the use of multiple monitors.

  14. Considerations for Bioassay Monitoring of Mixtures of Radionuclides

    DOE PAGES

    Klumpp, John; Waters, Tom; Bertelli, Luiz

    2017-10-01

    Complying with regulations for bioassay monitoring of radionuclide intakes is significantly more complex for mixtures than it is for pure radionuclides. Different constituents will naturally have different dose coefficients, be detectable at significantly different levels, and may require very different amounts of effort to bioassay. The ability to use certain constituents as surrogates for others will depend on how well characterized the mixture is, as well as whether the employee is also working with other radionuclides. This is further compounded by the fact that the composition of a mixture (or even of a pure radionuclide) is likely to change overmore » time. Internal dosimetrists must decide how best to monitor employees who work with radionuclide mixtures. In particular, they must decide which constituents should be monitored routinely, which constituents only need to be monitored in the case of an intake, and how to estimate doses based on intakes of monitored and unmonitored constituents.« less

  15. Recommendations to harmonize European early warning dosimetry network systems

    NASA Astrophysics Data System (ADS)

    Dombrowski, H.; Bleher, M.; De Cort, M.; Dabrowski, R.; Neumaier, S.; Stöhlker, U.

    2017-12-01

    After the Chernobyl nuclear power plant accident in 1986, followed by the Fukushima Nuclear power plant accident 25 years later, it became obvious that real-time information is required to quickly gain radiological information. As a consequence, the European countries established early warning network systems with the aim to provide an immediate warning in case of a major radiological emergency, to supply reliable information on area dose rates, contamination levels, radioactivity concentrations in air and finally to assess public exposure. This is relevant for governmental decisions on intervention measures in an emergency situation. Since different methods are used by national environmental monitoring systems to measure area dose rate values and activity concentrations, there are significant differences in the results provided by different countries. Because European and neighboring countries report area dose rate data to a central data base operated on behalf of the European Commission, the comparability of the data is crucial for its meaningful interpretation, especially in the case of a nuclear accident with transboundary implications. Only by harmonizing measuring methods and data evaluation, is the comparability of the dose rate data ensured. This publication concentrates on technical requirements and methods with the goal to effectively harmonize area dose rate monitoring data provided by automatic early warning network systems. The requirements and procedures laid down in this publication are based on studies within the MetroERM project, taking into account realistic technical approaches and tested procedures.

  16. A user friendly database for use in ALARA job dose assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zodiates, A.M.; Willcock, A.

    1995-03-01

    The pressurized water reactor (PWR) design chosen for adoption by Nuclear Electric plc was based on the Westinghouse Standard Nuclear Unit Power Plant (SNUPPS). This design was developed to meet the United Kingdom requirements and these improvements are embodied in the Sizewell B plant which will start commercial operation in 1994. A user-friendly database was developed to assist the station in the dose and ALARP assessments of the work expected to be carried out during station operation and outage. The database stores the information in an easily accessible form and enables updating, editing, retrieval, and searches of the information. Themore » database contains job-related information such as job locations, number of workers required, job times, and the expected plant doserates. It also contains the means to flag job requirements such as requirements for temporary shielding, flushing, scaffolding, etc. Typical uses of the database are envisaged to be in the prediction of occupational doses, the identification of high collective and individual dose jobs, use in ALARP assessments, setting of dose targets, monitoring of dose control performance, and others.« less

  17. Perspectives of UV nowcasting to monitor personal pro-health outdoor activities.

    PubMed

    Krzyścin, Janusz W; Lesiak, Aleksandra; Narbutt, Joanna; Sobolewski, Piotr; Guzikowski, Jakub

    2018-07-01

    Nowcasting model for online monitoring of personal outdoor behaviour is proposed. It is envisaged that it will provide an effective e-tool used by smartphone users. The model could estimate maximum duration of safe (without erythema risk) outdoor activity. Moreover, there are options to estimate duration of sunbathing to get adequate amount of vitamin D 3 and doses necessary for the antipsoriatic heliotherapy. The application requires information of starting time of sunbathing and the user's phototype. At the beginning the user will be informed of the approximate duration of sunbathing required to get the minimum erythemal dose, adequate amount of vitamin D 3 , and the dose necessary for the antipsoriatic heliotherapy. After every 20-min the application will recalculate the remaining duration of sunbathing based on the UVI measured in the preceding 20 min. If the estimate of remaining duration is <20 min the user will be informed that the deadline of sunbathing is approaching. Finally, a warning signal will be sent to stop sunbathing if the measured dose reaches the required dose. The proposed model is verified using the data collected at two measuring sites for the warm period of 2017 (1st April-30th September) in large Polish cities (Warsaw and Lodz). First instrument represents the UVI monitoring station. The information concerning sunbathing duration, which is sent to a remote user, is evaluated on the basis of the UVI measurements collected by the second measuring unit in a distance of ~7 km and 10 km for Warsaw and Lodz, respectively. The statistical analysis of the differences between sunbathing duration by nowcasting model and observation shows that the model provides reliable doses received by the users during outdoor activities in proximity (~10 km) to the UVI source site. Standard 24 h UVI forecast based on prognostic values of total ozone and cloudiness appears to only be valid for sunny days. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Development of methods to monitor ionization modification from dosing vehicles and phospholipids in study samples.

    PubMed

    Chang, Min; Li, Yongchao; Angeles, Reginald; Khan, Samina; Chen, Lian; Kaplan, Julia; Yang, Liyu

    2011-08-01

    Two approaches to monitor the matrix effect on ionization in study samples were described. One approach is the addition of multiple reaction monitoring transitions to the bioanalytical methods to monitor the presence of known ionization modification-causing components of the matrix, for example, m/z 184→125 (or m/z 184→184) and m/z 133→89 may be used for phospholipids and polyethylene oxide containing surfactants, respectively. This approach requires no additional equipment and can be readily adapted for most method. The approach detects only the intended interfering compounds and provides little quantitative indication if the matrix effect is within the tolerable range (±15%). The other approach requires the addition of an infusion pump and identifies an appropriate surrogate of the analyte to be infused for the determination of modification on the ionization of the analyte. The second approach detects interferences in the sample regardless of the sources (i.e., dosing vehicle components, co-administrated drugs, their metabolites, phospholipids, plasticizers and endogenous components introduced due to disease stage).

  19. [Incorporation monitoring of employees of a radioiodine therapy ward. Is incorporation monitoring required for routine?].

    PubMed

    Happel, C; Kratzel, U; Selkinski, I; Bockisch, B; Etzel, M; Korkusuz, H; Sauter, B; Staudt, J; von Müller, F; Grünwald, F; Kranert, W T

    2013-01-01

    Aim of the study was to determine the annual incorporation of staff on a radioiodine therapy ward and the resulting annual effective dose (aed). Following the German incorporation guideline (gig), incorporation monitoring is not necessary for potential aed below 0.5 mSv/a. For aed > 0.5 mSv/a adherence to the 1 mSv dose limit must be verified. For doses > 1 mSv/a incorporation has to be monitored by the authority. Furthermore, the (131)I incorporation factor from the gig should be verified. To determine the actual work related incorporation, the (131)I activity concentration in urine samples (collection over 24 h) of 14 employees of different professions were examined over a period of 27 months. Measured activity concentrations were related to the individual time of exposure. A constant activity supply for at least three days was assumed. The mean annual effective doses were 2.4 · 10⁻¹ mSv/a (nursing staff; n = 3), 5.6 · 10⁻² mSv/a (cleaning staff; n = 2), 2.8 · 10⁻³ mSv/a (technical staff; n = 2) and 5.2 · 10⁻³ mSv/a (physicians; n = 7). All aed were below the dose limits of the gig. The calculated mean incorporation factors ranged from 3.0 · 10⁻⁸ for the nursing staff to 3.6 · 10⁻¹⁰ for the technical staff (cleaning staff: 7 · 10⁻⁹; physicians: 6.5 · 10⁻¹⁰) and were therefore well below the (131)I incorporation factor defined by the gig. To estimate the aed caused by incorporation of (131)I it has to be subdivided for the different requirements in the diverse fields of activity of the employees. Regarding those who spend most of their time nearby the patient an incorporation monitoring by the authority might be required. The (131)I incorporation factor from the guideline (10⁻⁶) can be reduced by a factor of 10. For (99m)Tc and (18)F an incorporation factor of 10⁻⁷ is accepted.

  20. Monitoring and Management of Toxicities of Novel B Cell Signaling Agents.

    PubMed

    Rhodes, Joanna; Mato, Anthony; Sharman, Jeff P

    2018-04-11

    B cell signaling agents, including ibrutinib, idelalisib, and the BCL-2 inhibitor venetoclax have become an integral part of therapy for patients with non-Hodgkin's lymphomas. The toxicity profiles of these medications is distinct from chemoimmunotherapy. Here, we will review the mechanism of action of these drugs, their efficacy, and toxicity management. Ibrutinib use is associated with increased risk of atrial fibrillation and bleeding which can be managed using dose interruptions and modifications. Patients on idelalisib require close clinical and frequent laboratory monitoring, particularly of liver function tests to ensure there are no serious adverse events. Monitoring for infections is important in patients on both idelalisib and ibrutinib. Venetoclax requires close clinical and laboratory monitoring to prevent significant tumor lysis. Targeted B cell receptor therapies each have unique side effect profiles which require careful clinical monitoring. As we continue to use these therapies, optimal management strategies will continue to be elucidated.

  1. SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Och, J

    2016-06-15

    Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinicalmore » Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.« less

  2. Self-indicating radiation alert dosemeter (SIRAD).

    PubMed

    Riel, Gordon K; Winters, Patrick; Patel, Gordhan; Patel, Paresh

    2006-01-01

    In an event of a nuclear or dirty bomb explosion and a radiological accident, there is a need for self-indicating instant radiation dosemeter for monitoring radiation exposure. The self-indicating instant radiation alert dosemeter (SIRAD) is a credit card size radiation dosemeter for monitoring ionising radiation from a few hundredths of a Gray to a few Gray. It is always active and is ready to use. It needs no battery. The dosemeter develops colour instantly upon exposure, and the colour intensifies with dose. It has a colour chart so that the dose on the active element may be read by matching its colour with the chart that is printed next to it on the card. However, in this work, the dose is measured by the optical density of the element. The dosemeter cannot be reset. The response changes by <1% per degrees C from -20 to +60 degrees C. The shelf-life is >3 y at room temperature. It contains no hazardous materials. The dosemeter would meet the requirements of instantly monitoring high dose in an event of a nuclear or dirty bomb explosion or a radiation accident.

  3. Hanford internal dosimetry program manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, E.H.; Sula, M.J.; Bihl, D.E.

    1989-10-01

    This document describes the Hanford Internal Dosimetry program. Program Services include administrating the bioassay monitoring program, evaluating and documenting assessments of internal exposure and dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating internal radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. 13 refs., 16 figs., 42 tabs.

  4. Characterization of optically stimulated luminescence dosimeters and investigating their potential for estimating pediatric organ doses in multi-slice computed tomography

    NASA Astrophysics Data System (ADS)

    Al-Senan, Rani Mohammed

    Recent epidemiologic studies have shown a strong association between the relatively high doses of pediatric CT and the risk of cancer. Quantifying organ doses, as a measure of the risk, is commonly based on either direct anthropomorphic phantom measurements or Monte Carlo simulation. The major disadvantage in the phantom approach is its high cost especially that, for pediatric CT dosimetry, various phantom sizes are required to represent different age groups of children. On the other hand, Monte Carlo simulation, although not considered costly, requires validation by anthropomorphic phantom measurements. The aim of this project was to develop two methods of organ dose estimation in pediatric CT: 1) from the measured surface dose using optically stimulated luminescence dosimeters (OSLDs) and 2) by measuring the circumference of the body part being scanned as well as knowing the scan parameters. The project was based on a study proposed by the surgery department to monitor radiation exposure to children during their CT examination in the ER. A total of 200 pediatric patients were enrolled in this study which used OSLDs to monitor the doses. Specific aim 1 of this project was to characterize the OSLDs in the diagnostic energy range. Specific aim 2(a) was to find relationships between the patients' doses from OSLDs and both scan CTDI and the measured circumference. In specific aim 2(b) we carried out measurements using CTDI phantoms to investigate the relationships studied in specific aim 2(a). Specific aim 3 was to come up with models to estimate select organ doses from measuring surface dose or by using the circumference of the body part. To do this, pediatric examinations were simulated using a set of pediatric anthropomorphic phantoms in which doses of select organs were measured.

  5. Reconstruction of Internal Doses for the Alpha-Risk Case-Control Study of Lung Cancer and Leukaemia Among European Nuclear Workers.

    PubMed

    Bingham, Derek; Bérard, Philippe; Birchall, Alan; Bull, Richard; Cardis, Elisabeth; Challeton-de Vathaire, Cécile; Grellier, James; Hurtgen, Christian; Puncher, Matthew; Riddell, Anthony; Thierry-Chef, Isabelle

    2017-05-01

    The Alpha-Risk study required the reconstruction of doses to lung and red bone marrow for lung cancer and leukaemia cases and their matched controls from cohorts of nuclear workers in the UK, France and Belgium. The dosimetrists and epidemiologists agreed requirements regarding the bioassay data, biokinetic and dosimetric models and dose assessment software to be used and doses to be reported. The best values to use for uncertainties on the monitoring data, setting of exposure regimes and characteristics of the exposure material, including lung solubility, were the responsibility of the dosimetrist responsible for each cohort. Among 1721 subjects, the median absorbed dose to the lung from alpha radiations was 2.1 mGy, with a maximum dose of 316 mGy. The lung doses calculated reflect the higher levels of exposure seen among workers in the early years of the nuclear industry compared to today. © Crown copyright 2016.

  6. Improving IMRT delivery efficiency using intensity limits during inverse planning.

    PubMed

    Coselmon, Martha M; Moran, Jean M; Radawski, Jeffrey D; Fraass, Benedick A

    2005-05-01

    Inverse planned intensity modulated radiotherapy (IMRT) fields can be highly modulated due to the large number of degrees of freedom involved in the inverse planning process. Additional modulation typically results in a more optimal plan, although the clinical rewards may be small or offset by additional delivery complexity and/or increased dose from transmission and leakage. Increasing modulation decreases delivery efficiency, and may lead to plans that are more sensitive to geometrical uncertainties. The purpose of this work is to assess the use of maximum intensity limits in inverse IMRT planning as a simple way to increase delivery efficiency without significantly affecting plan quality. Nine clinical cases (three each for brain, prostate, and head/neck) were used to evaluate advantages and disadvantages of limiting maximum intensity to increase delivery efficiency. IMRT plans were generated using in-house protocol-based constraints and objectives for the brain and head/neck, and RTOG 9406 dose volume objectives in the prostate. Each case was optimized at a series of maximum intensity ratios (the product of the maximum intensity and the number of beams divided by the prescribed dose to the target volume), and evaluated in terms of clinical metrics, dose-volume histograms, monitor units (MU) required per fraction (SMLC and DMLC delivery), and intensity map variation (a measure of the beam modulation). In each site tested, it was possible to reduce total monitor units by constraining the maximum allowed intensity without compromising the clinical acceptability of the plan. Monitor unit reductions up to 38% were observed for SMLC delivery, while reductions up to 29% were achieved for DMLC delivery. In general, complicated geometries saw a smaller reduction in monitor units for both delivery types, although DMLC delivery required significantly more monitor units in all cases. Constraining the maximum intensity in an inverse IMRT plan is a simple way to improve delivery efficiency without compromising plan objectives.

  7. Dose-dependent effects of cannabis on the neural correlates of error monitoring in frequent cannabis users.

    PubMed

    Kowal, Mikael A; van Steenbergen, Henk; Colzato, Lorenza S; Hazekamp, Arno; van der Wee, Nic J A; Manai, Meriem; Durieux, Jeffrey; Hommel, Bernhard

    2015-11-01

    Cannabis has been suggested to impair the capacity to recognize discrepancies between expected and executed actions. However, there is a lack of conclusive evidence regarding the acute impact of cannabis on the neural correlates of error monitoring. In order to contribute to the available knowledge, we used a randomized, double-blind, between-groups design to investigate the impact of administration of a low (5.5 mg THC) or high (22 mg THC) dose of vaporized cannabis vs. placebo on the amplitudes of the error-related negativity (ERN) and error positivity (Pe) in the context of the Flanker task, in a group of frequent cannabis users (required to use cannabis minimally 4 times a week, for at least 2 years). Subjects in the high dose group (n=18) demonstrated a significantly diminished ERN in comparison to the placebo condition (n=19), whereas a reduced Pe amplitude was observed in both the high and low dose (n=18) conditions, as compared to placebo. The results suggest that a high dose of cannabis may affect the neural correlates of both the conscious (late), as well as the initial automatic processes involved in error monitoring, while a low dose of cannabis might impact only the conscious (late) processing of errors. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.

  8. Continuous monitoring and intrafraction target position correction during treatment improves target coverage for patients undergoing SBRT prostate therapy.

    PubMed

    Lovelock, D Michael; Messineo, Alessandra P; Cox, Brett W; Kollmeier, Marisa A; Zelefsky, Michael J

    2015-03-01

    To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Continuous Monitoring and Intrafraction Target Position Correction During Treatment Improves Target Coverage for Patients Undergoing SBRT Prostate Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovelock, D. Michael, E-mail: lovelocm@mskcc.org; Messineo, Alessandra P.; Cox, Brett W.

    2015-03-01

    Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting themore » couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.« less

  10. Prospective drug safety monitoring using the UK primary-care General Practice Research Database: theoretical framework, feasibility analysis and extrapolation to future scenarios.

    PubMed

    Johansson, Saga; Wallander, Mari-Ann; de Abajo, Francisco J; García Rodríguez, Luis Alberto

    2010-03-01

    Post-launch drug safety monitoring is essential for the detection of adverse drug signals that may be missed during preclinical trials. Traditional methods of postmarketing surveillance such as spontaneous reporting have intrinsic limitations, many of which can be overcome by the additional application of structured pharmacoepidemiological approaches. However, further improvement in drug safety monitoring requires a shift towards more proactive pharmacoepidemiological methods that can detect adverse drug signals as they occur in the population. To assess the feasibility of using proactive monitoring of an electronic medical record system, in combination with an independent endpoint adjudication committee, to detect adverse events among users of selected drugs. UK General Practice Research Database (GPRD) information was used to detect acute liver disorder associated with the use of amoxicillin/clavulanic acid (hepatotoxic) or low-dose aspirin (acetylsalicylic acid [non-hepatotoxic]). Individuals newly prescribed these drugs between 1 October 2005 and 31 March 2006 were identified. Acute liver disorder cases were assessed using GPRD computer records in combination with case validation by an independent endpoint adjudication committee. Signal generation thresholds were based on the background rate of acute liver disorder in the general population. Over a 6-month period, 8148 patients newly prescribed amoxicillin/clavulanic acid and 5577 patients newly prescribed low-dose aspirin were identified. Within this cohort, searches identified 11 potential liver disorder cases from computerized records: six for amoxicillin/clavulanic acid and five for low-dose aspirin. The independent endpoint adjudication committee refined this to four potential acute liver disorder cases for whom paper-based information was requested for final case assessment. Final case assessments confirmed no cases of acute liver disorder. The time taken for this study was 18 months (6 months for recruitment and 12 months for data management and case validation). To reach the estimated target exposure necessary to raise or rule out a signal of concern to public health, we determined that a recruitment period 2-3 times longer than that used in this study would be required. Based on the real market uptake of six commonly used medicinal products launched between 2001 and 2006 in the UK (budesonide/eformoterol [fixed-dose combination], duloxetine, ezetimibe, metformin/rosiglitazone [fixed-dose combination], tiotropium bromide and tadalafil) the target exposure would not have been reached until the fifth year of marketing using a single database. It is feasible to set up a system that actively monitors drug safety using a healthcare database and an independent endpoint adjudication committee. However, future successful implementation will require multiple databases to be queried so that larger study populations are included. This requires further development and harmonization of international healthcare databases.

  11. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals.

    PubMed

    Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh

    2016-10-05

    The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel.

  12. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals

    PubMed Central

    Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh

    2016-01-01

    Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel. PMID:27751973

  13. A review on therapeutic drug monitoring of immunosuppressant drugs.

    PubMed

    Mohammadpour, Niloufar; Elyasi, Sepideh; Vahdati, Naser; Mohammadpour, Amir Hooshang; Shamsara, Jamal

    2011-11-01

    : Immunosuppressants require therapeutic drug monitoring because of their narrow therapeutic index and significant inter-individual variability in blood concentrations. This variability can be because of factors like drug-nutrient interactions, drug-disease interactions, renal-insufficiency, inflammation and infection, gender, age, polymorphism and liver mass. Drug monitoring is widely practiced especially for cyclosporine, tacrolimus, sirolimus and mycophenolic acid. CYCLOSPORINE: Therapeutic monitoring of immunosuppressive therapy with cyclosporine is a critical requirement because of intra- and inter-patient variability of drug absorption, narrow therapeutic window and drug induced nephrotoxicity. MYCOPHENOLIC ACID MPA: Some reasons for therapeutic drug monitoring of MPA during post-transplant period include: relationship between MPA pharmacokinetic parameters and clinical outcomes, Inter-patient pharmacokinetic variability for MPA despite fixed MMF doses, alternations of MPA pharmacokinetics during the first months after transplantation, drug- drug interaction and influence of kidney function on MPA pharmacokinetic. SIROLIMUS: A recent review of the pharmacokinetics of sirolimus suggested a therapeutic range of 5 to 10 μg l(-1) in whole blood. However, the only consensus guidelines published on the therapeutic monitoring of sirolimus concluded that there was not enough information available about the clinical use of the drug to make recommendations. TACROLIMUS: Sudies have shown, in kidney and liver transplant patients, significant associations of low tacrolimus concentrations with rejection and of high concentrations with nephrotoxicity. Although the feasibility of a limited sampling scheme to predict AUC has been demonstrated, as yet, trough, or pre-dose, whole blood concentration monitoring is still the method of choice.

  14. Development of requirements for environmental specimen banking in ecological monitoring (exemplified by the Chernobyl NPP accident area).

    PubMed

    Borzilov, V A

    1993-11-01

    Development of requirements for a data bank for natural media as a system of intercorrelated parameters to estimate system states are determined. The problems of functional agreement between experimental and calculation methods are analysed when organizing the ecological monitoring. The methods of forming the environmental specimen bank to estimate and forecast radioactive contamination and exposure dose are considered to be exemplified by the peculiarities of the spatial distribution of radioactive contamination in fields. Analysed is the temporal dynamics of contamination for atmospheric air, soil and water.

  15. Six steps to a successful dose-reduction strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, M.

    1995-03-01

    The increased importance of demonstrating achievement of the ALARA principle has helped produce a proliferation of dose-reduction ideas. Across a company there may be many dose-reduction items being pursued in a variety of areas. However, companies have a limited amount of resource and, therefore, to ensure funding is directed to those items which will produce the most benefit and that all areas apply a common policy, requires the presence of a dose-reduction strategy. Six steps were identified in formulating the dose-reduction strategy for Rolls-Royce and Associates (RRA): (1) collating the ideas; (2) quantitatively evaluating them on a common basis; (3)more » prioritizing the ideas in terms of cost benefit, (4) implementation of the highest priority items; (5) monitoring their success; (6) periodically reviewing the strategy. Inherent in producing the dose-reduction strategy has been a comprehensive dose database and the RRA-developed dose management computer code DOMAIN, which allows prediction of dose rates and dose. The database enabled high task dose items to be identified, assisted in evaluating dose benefits, and monitored dose trends once items had been implemented. The DOMAIN code was used both in quantifying some of the project dose benefits and its results, such as dose contours, used in some of the dose-reduction items themselves. In all, over fifty dose-reduction items were evaluated in the strategy process and the items which will give greatest benefit are being implemented. The strategy has been successful in giving renewed impetus and direction to dose-reduction management.« less

  16. Volumetric modulated arc therapy vs. IMRT for the treatment of distal esophageal cancer.

    PubMed

    Van Benthuysen, Liam; Hales, Lee; Podgorsak, Matthew B

    2011-01-01

    Several studies have demonstrated that volumetric modulated arc therapy (VMAT) has the ability to reduce monitor units and treatment time when compared with intensity-modulated radiation therapy (IMRT). This study aims to demonstrate that VMAT is able to provide adequate organs at risk (OAR) sparing and planning target volume (PTV) coverage for adenocarcinoma of the distal esophagus while reducing monitor units and treatment time. Fourteen patients having been treated previously for esophageal cancer were planned using both VMAT and IMRT techniques. Dosimetric quality was evaluated based on doses to several OARs, as well as coverage of the PTV. Treatment times were assessed by recording the number of monitor units required for dose delivery. Body V(5) was also recorded to evaluate the increased volume of healthy tissue irradiated to low doses. Dosimetric differences in OAR sparing between VMAT and IMRT were comparable. PTV coverage was similar for the 2 techniques but it was found that IMRT was capable of delivering a slightly more homogenous dose distribution. Of the 14 patients, 12 were treated with a single arc and 2 were treated with a double arc. Single-arc plans reduced monitor units by 42% when compared with the IMRT plans. Double-arc plans reduced monitor units by 67% when compared with IMRT. The V(5) for the body was found to be 18% greater for VMAT than for IMRT. VMAT has the capability to decrease treatment times over IMRT while still providing similar OAR sparing and PTV coverage. Although there will be a smaller risk of patient movement during VMAT treatments, this advantage comes at the cost of delivering small doses to a greater volume of the patient. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  17. Measurement of charged particle yields from therapeutic beams in view of the design of an innovative hadrontherapy dose monitor

    NASA Astrophysics Data System (ADS)

    Battistoni, G.; Bellini, F.; Bini, F.; Collamati, F.; Collini, F.; De Lucia, E.; Durante, M.; Faccini, R.; Ferroni, F.; Frallicciardi, P. M.; La Tessa, C.; Marafini, M.; Mattei, I.; Miraglia, F.; Morganti, S.; Ortega, P. G.; Patera, V.; Piersanti, L.; Pinci, D.; Russomando, A.; Sarti, A.; Schuy, C.; Sciubba, A.; Senzacqua, M.; Solfaroli Camillocci, E.; Vanstalle, M.; Voena, C.

    2015-02-01

    Particle Therapy (PT) is an emerging technique, which makes use of charged particles to efficiently cure different kinds of solid tumors. The high precision in the hadrons dose deposition requires an accurate monitoring to prevent the risk of under-dosage of the cancer region or of over-dosage of healthy tissues. Monitoring techniques are currently being developed and are based on the detection of particles produced by the beam interaction into the target, in particular: charged particles, result of target and/or projectile fragmentation, prompt photons coming from nucleus de-excitation and back-to-back γ s, produced in the positron annihilation from β + emitters created in the beam interaction with the target. It has been showed that the hadron beam dose release peak can be spatially correlated with the emission pattern of these secondary particles. Here we report about secondary particles production (charged fragments and prompt γ s) performed at different beam and energies that have a particular relevance for PT applications: 12C beam of 80 MeV/u at LNS, 12C beam 220 MeV/u at GSI, and 12C, 4He, 16O beams with energy in the 50-300 MeV/u range at HIT. Finally, a project for a multimodal dose-monitor device exploiting the prompt photons and charged particles emission will be presented.

  18. [EEG-adjusted target-controlled infusion : Propofol target concentration with different doses of remifentanil].

    PubMed

    Büttner, N; Schultz, B; Grouven, U; Schultz, A

    2010-02-01

    The aim of this study was to examine to what extent the use of electroencephalography (EEG) monitoring leads to an adaptation of the target-controlled infusion (TCI) concentration of propofol during propofol anaesthesia with different doses of remifentanil. With ethics committee approval 60 patients (27-69 years old) with American Society of Anesthesiologists classification (ASA) I-III received anaesthestics with propofol (TCI, Diprifusor, AstraZeneca, Wedel, Deutschland) and 0.2, 0.4, or 0.6 microg/kg body weight remifentanil, respectively (groups 1-3). Anaesthesia was maintained at a level of deep hypnosis (EEG stages D(2)/E(0), EEG monitor: Narcotrend, version 2.0/5.0, manufacturer: MT MonitorTechnik, Bad Bramstedt, Germany). During the steady state the propofol concentration in groups 1-3 was 3.02+/-0.86, 1.93+/-0.53 and 1.60+/-0.55 microg/ml, respectively (p<0.001). Women had a higher propofol consumption than men (p<0.05). Dreams during anaesthesia were more often reported by women than by men (p<0.05). The need for postoperative analgesia decreased with an increasing intraoperative remifentanil dose (p<0.05). The study demonstrates that remifentanil has both analgetic and hypnotic effects. With increasing remifentanil dose the propofol requirement decreased and in this context EEG monitoring is useful to adapt the target concentrations of propofol to the patients' age and gender.

  19. Some computer graphical user interfaces in radiation therapy.

    PubMed

    Chow, James C L

    2016-03-28

    In this review, five graphical user interfaces (GUIs) used in radiation therapy practices and researches are introduced. They are: (1) the treatment time calculator, superficial X-ray treatment time calculator (SUPCALC) used in the superficial X-ray radiation therapy; (2) the monitor unit calculator, electron monitor unit calculator (EMUC) used in the electron radiation therapy; (3) the multileaf collimator machine file creator, sliding window intensity modulated radiotherapy (SWIMRT) used in generating fluence map for research and quality assurance in intensity modulated radiation therapy; (4) the treatment planning system, DOSCTP used in the calculation of 3D dose distribution using Monte Carlo simulation; and (5) the monitor unit calculator, photon beam monitor unit calculator (PMUC) used in photon beam radiation therapy. One common issue of these GUIs is that all user-friendly interfaces are linked to complex formulas and algorithms based on various theories, which do not have to be understood and noted by the user. In that case, user only needs to input the required information with help from graphical elements in order to produce desired results. SUPCALC is a superficial radiation treatment time calculator using the GUI technique to provide a convenient way for radiation therapist to calculate the treatment time, and keep a record for the skin cancer patient. EMUC is an electron monitor unit calculator for electron radiation therapy. Instead of doing hand calculation according to pre-determined dosimetric tables, clinical user needs only to input the required drawing of electron field in computer graphical file format, prescription dose, and beam parameters to EMUC to calculate the required monitor unit for the electron beam treatment. EMUC is based on a semi-experimental theory of sector-integration algorithm. SWIMRT is a multileaf collimator machine file creator to generate a fluence map produced by a medical linear accelerator. This machine file controls the multileaf collimator to deliver intensity modulated beams for a specific fluence map used in quality assurance or research. DOSCTP is a treatment planning system using the computed tomography images. Radiation beams (photon or electron) with different energies and field sizes produced by a linear accelerator can be placed in different positions to irradiate the tumour in the patient. DOSCTP is linked to a Monte Carlo simulation engine using the EGSnrc-based code, so that 3D dose distribution can be determined accurately for radiation therapy. Moreover, DOSCTP can be used for treatment planning of patient or small animal. PMUC is a GUI for calculation of the monitor unit based on the prescription dose of patient in photon beam radiation therapy. The calculation is based on dose corrections in changes of photon beam energy, treatment depth, field size, jaw position, beam axis, treatment distance and beam modifiers. All GUIs mentioned in this review were written either by the Microsoft Visual Basic.net or a MATLAB GUI development tool called GUIDE. In addition, all GUIs were verified and tested using measurements to ensure their accuracies were up to clinical acceptable levels for implementations.

  20. Dose Control System in the Optima XE Single Wafer High Energy Ion Implanter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Satoh, Shu; Yoon, Jongyoon; David, Jonathan

    2011-01-07

    Photoresist outgassing can significantly compromise accurate dosimetry of high energy implants. High energy implant even at a modest beam current produces high beam powers which create significantly worse outgassing than low and medium energy implants and the outgassing continues throughout the implant due to the low dose in typical high energy implant recipes. In the previous generation of high energy implanters, dose correction by monitoring of process chamber pressure during photoresist outgassing has been used. However, as applications diversify and requirements change, the need arises for a more versatile photoresist correction system to match the versatility of a single wafermore » high energy ion implanter. We have successfully developed a new dosimetry system for the Optima XE single wafer high energy ion implanter which does not require any form of compensation due to the implant conditions. This paper describes the principles and performance of this new dose system.« less

  1. Triple ionization chamber method for clinical dose monitoring with a Be-covered Li BNCT field.

    PubMed

    Nguyen, Thanh Tat; Kajimoto, Tsuyoshi; Tanaka, Kenichi; Nguyen, Chien Cong; Endo, Satoru

    2016-11-01

    Fast neutron, gamma-ray, and boron doses have different relative biological effectiveness (RBE). In boron neutron capture therapy (BNCT), the clinical dose is the total of these dose components multiplied by their RBE. Clinical dose monitoring is necessary for quality assurance of the irradiation profile; therefore, the fast neutron, gamma-ray, and boron doses should be separately monitored. To estimate these doses separately, and to monitor the boron dose without monitoring the thermal neutron fluence, the authors propose a triple ionization chamber method using graphite-walled carbon dioxide gas (C-CO 2 ), tissue-equivalent plastic-walled tissue-equivalent gas (TE-TE), and boron-loaded tissue-equivalent plastic-walled tissue-equivalent gas [TE(B)-TE] chambers. To use this method for dose monitoring for a neutron and gamma-ray field moderated by D 2 O from a Be-covered Li target (Be-covered Li BNCT field), the relative sensitivities of these ionization chambers are required. The relative sensitivities of the TE-TE, C-CO 2 , and TE(B)-TE chambers to fast neutron, gamma-ray, and boron doses are calculated with the particle and heavy-ion transport code system (PHITS). The relative sensitivity of the TE(B)-TE chamber is calculated with the same method as for the TE-TE and C-CO 2 chambers in the paired chamber method. In the Be-covered Li BNCT field, the relative sensitivities of the ionization chambers to fast neutron, gamma-ray, and boron doses are calculated from the kerma ratios, mass attenuation coefficient tissue-to-wall ratios, and W-values. The Be-covered Li BNCT field consists of neutrons and gamma-rays which are emitted from a Be-covered Li target, and this resultant field is simulated by using PHITS with the cross section library of ENDF-VII. The kerma ratios and mass attenuation coefficient tissue-to-wall ratios are determined from the energy spectra of neutrons and gamma-rays in the Be-covered Li BNCT field. The W-value is calculated from recoil charged particle spectra by the collision of neutrons and gamma-rays with the wall and gas materials of the ionization chambers in the gas cavities of TE-TE, C-CO 2 , and TE(B)-TE chambers ( 10 B concentrations of 10, 50, and 100 ppm in the TE-wall). The calculated relative sensitivity of the C-CO 2 chamber to the fast neutron dose in the Be-covered Li BNCT field is 0.029, and those of the TE-TE and TE(B)-TE chambers are both equal to 0.965. The relative sensitivities of the C-CO 2 , TE-TE, and TE(B)-TE chambers to the gamma-ray dose in the Be-covered Li BNCT field are all 1 within the 1% calculation uncertainty. The relative sensitivities of TE(B)-TE to boron dose with concentrations of 10, 50, and 100 ppm 10 B are calculated to be 0.865 times the ratio of the in-tumor to in-chamber wall boron concentration. The fast neutron, gamma-ray, and boron doses of a tumor in-air can be separately monitored by the triple ionization chamber method in the Be-covered Li BNCT field. The results show that these doses can be easily converted to the clinical dose with the depth correction factor in the body and the RBE.

  2. Requirements for authorisation of internal dosimetry services.

    PubMed

    Melo, D R; Cunha, P G; Torres, M M C; Lourenço, M C

    2003-01-01

    In order to ensure that a facility is in compliance with the occupational exposure requirements established by regulatory authorities, the measurements and dose assessments specified in the individual monitoring programme need to be reliable. There are two important questions that shall be addressed here: one is how the licensed facilities can demonstrate to their workers and regulatory bodies compliance with the regulatory limits and the reliability of the results of the individual monitoring programmes; the other concerns the mechanisms used to demonstrate to a facility in another country the reliability of the measurement results of an individual monitoring bioassay programme. The accreditation of the bioassay laboratory, according to ISO/IEC 17025, shall be the basic requirement for obtaining the authorisation granted by the national regulatory authority. For the second question, such confidence can be achieved through International Laboratory Accreditation Cooperation (ILAC).

  3. Influence of Successful Chronic Hepatitis C Virus Treatment with Ledipasvir/Sofosbuvir on Warfarin Dosing Requirements in Four Veterans.

    PubMed

    Britnell, Sara R; Willets, Amy E; Vanderman, Adam J; Woodard, Catherine L; Britt, Rachel B

    2016-11-01

    To describe international normalized ratio (INR) trends and warfarin dosage adjustments required for four veterans who were receiving warfarin therapy and started treatment for hepatitis C virus (HCV) with ledipasvir/sofosbuvir with or without ribavirin. Case series. Pharmacist-led anticoagulation clinic in a Veterans Affairs Health Care System. Four patients aged 59-66 years who were receiving warfarin and had stable, therapeutic INRs and started ledipasvir/sofosbuvir therapy with or without ribavirin for HCV infection. All four patients developed subtherapeutic INRs after the addition of ledipasvir/sofosbuvir with or without ribavirin. An increase in weekly warfarin dose ranging from 14-67% was required, with changes in warfarin doses starting 2-3 weeks after ledipasvir/sofosbuvir initiation. Two patients required dose reductions after HCV treatment completion, whereas the other two did not. Use of the Drug Interaction Probability Scale indicated that the interaction between warfarin and ledipasvir/sofosbuvir was doubtful (score of 1 [two patients]) or possible (score of 4 [two patients]). The mechanism of this interaction is unknown but may be related to improvements in hepatic function during HCV treatment. To our knowledge, this is the first case series describing a possible drug interaction between warfarin and ledipasvir/sofosbuvir (with or without ribavirin). Close monitoring is warranted when ledipasvir/sofosbuvir is initiated in patients receiving anticoagulation therapy with warfarin, especially those with evidence of cirrhosis prior to treatment. This is particularly important in the first month after starting treatment and the first month after completion. Failure to monitor and achieve therapeutic INR after HCV therapy completion may have the potential to result in adverse outcomes. © 2016 Pharmacotherapy Publications, Inc.

  4. A new treatment regimen with high-dose and fractioned immunoglobulin in a special subgroup of severe and dependent CIDP patients.

    PubMed

    Debs, Rabab; Reach, Pauline; Cret, Corina; Demeret, Sophie; Saheb, Samir; Maisonobe, Thierry; Viala, Karine

    2017-10-01

    Chronic inflammatory demyelinating polyneuropathy (CIDP) is treated with intravenous immunoglobulins (IVIg), corticosteroids or plasma exchange (PE). IVIg dosage is not universal and markers for treatment management are needed. We report the response to high-dose and fractioned IVIg in a subgroup of definite CIDP patients, resistant to corticosteroids and PE, responders to IVIg but with an efficacy window <15 d. Four patients were included with similar predominantly clinical motor form and conduction abnormalities. Treatment management consisted of fractioning IVIg and increasing the monthly cumulated dose (mean: 3 g/kg/month). Serum IgG concentration was measured and correlated to the clinical state. Monitoring of serum IgG helped to guide IVIg administration dosage and frequency. A mean of 10 months was required to improve symptoms; therapy was then switched to subcutaneous (SC) route (maintenance dose: 3.5 g/kg/month). The mean Overall Neuropathy Limitations Scale was improved from 11 to 3.2 and the mean Medical Research Council scale from 26 to 90. It is important to distinguish patients with short IVIg efficacy window from those with classical resistance since the former may benefit from fractioning and increasing the IVIg dose. The monitoring of serum IgG level and its correlation to the clinical response could be of help in monitoring each individual's dosage.

  5. AIR KERMA TO Hp(3) CONVERSION COEFFICIENTS FOR IEC 61267 RQR X-RAY RADIATION QUALITIES: APPLICATION TO DOSE MONITORING OF THE LENS OF THE EYE IN MEDICAL DIAGNOSTICS.

    PubMed

    Principi, S; Guardiola, C; Duch, M A; Ginjaume, M

    2016-09-01

    Recent studies highlight the fact that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens monitoring could be required for these workers. The recommended operational quantity for monitoring of eye lens exposure is the personal dose equivalent at 3 mm depth Hp(3) (ICRU 51). However, there are no available conversion coefficients in international standards, while in the literature coefficients have only been calculated for monoenergetic beams and for ISO 4037-1 X-ray qualities. The aim of this article is to provide air kerma to Hp(3) conversion coefficients for a cylindrical phantom made of ICRU-4 elements tissue-equivalent material for RQR radiation qualities (IEC-61267) from 40 to 120 kV and for angles of incidence from 0 to 180°, which are characteristic of medical workplace. Analytic calculations using interpolation techniques and Monte Carlo modelling have been compared. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Paralytic ileus requiring hospitalization secondary to high-dose antipsychotic polypharmacy and benztropine.

    PubMed

    Kwiatkowski, Mercedes; Denka, Zachary D; White, Christopher C

    2011-01-01

    Ileus can result from the combined activity of antipsychotic and anticholinergic medications. Despite frequent use, case reports in the literature are sparse. We present a patient who developed a paralytic ileus requiring extended hospitalization. Providers should minimize antipsychotic and concurrent anticholinergic medications, consider prophylactic bowel regimens and monitor for constipation. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. [ESTIMATION OF IONIZING RADIATION EFFECTIVE DOSES IN THE INTERNATIONAL SPACE STATION CREWS BY THE METHOD OF CALCULATION MODELING].

    PubMed

    Mitrikas, V G

    2015-01-01

    Monitoring of the radiation loading on cosmonauts requires calculation of absorbed dose dynamics with regard to the stay of cosmonauts in specific compartments of the space vehicle that differ in shielding properties and lack means of radiation measurement. The paper discusses different aspects of calculation modeling of radiation effects on human body organs and tissues and reviews the effective dose estimates for cosmonauts working in one or another compartment over the previous period of the International space station operation. It was demonstrated that doses measured by a real or personal dosimeters can be used to calculate effective dose values. Correct estimation of accumulated effective dose can be ensured by consideration for time course of the space radiation quality factor.

  8. Measurement of the concentration of radon gas in the Toirano's caves (Liguria).

    PubMed

    Bruzzone, Diego; Bussallino, Massimo; Castello, Gianrico; Maggiolo, Stefano; Rossi, Daniela

    2006-01-01

    The radioactive gas radon, intermediate term of the decay series of uranium and thorium, is the main contamination source of underground places and may be a risk for high concentration and long exposure time. European and Italian law requires radon concentration to be measured in workplaces and, if the "action level" of 500 Bq/m3 is reached, proper actions must be made in order to decrease the dose commitment. Considering natural showcaves or artificial cavities open to public, the exposition of the visitors is frequently small, due to the short residence time, but accompanying people, remaining underground for long time, may be subject to appreciable dose and the radon concentration should therefore be monitored. The high humidity in natural caves may impair the use of some measuring devices. Therefore, different detection methods were compared (ZnS scintillation counters, E-PERM electret ionisation chambers, cellulose nitrate alpha-track dosimeters) to select the best procedure for long-term investigation. The LR-115 (Kodak) alpha-track dosimeters were insensitive to humidity and permitted to monitor a great number of places at the same time. Measurements have been carried out in the speleological and archaeological site of the Toirano's Caves (Savona, Liguria, Italy) and several points were monitored for two years. Radon concentration strongly depends on the site and changes during the year, due to the difference between internal and external temperature. The maximum dose commitment during the visitors tour, considering the average yearly value of radon concentration, was found to be between 1.5 and 4 microSv. It was found that no risk exists for visitors, but the evaluation of the dose absorbed by the guides and their classification according to the radiation protection law requires a complete monitoring of the average yearly concentration of radon and of the total time spent by each worker into the cave.

  9. Combined Use of a Patient Dose Monitoring System and a Real-Time Occupational Dose Monitoring System for Fluoroscopically Guided Interventions.

    PubMed

    Heilmaier, Christina; Kara, Levent; Zuber, Niklaus; Berthold, Christian; Weishaupt, Dominik

    2016-04-01

    To determine the effect on patient radiation exposure of the combined use of a patient dose monitoring system and real-time occupational dose monitoring during fluoroscopically guided interventions (FGIs). Patient radiation exposure, in terms of the kerma area product (KAP; Gy ∙ cm(2)), was measured in period 1 with a patient dose monitoring system, and a real-time occupational dose monitoring system was additionally applied in period 2. Mean/median KAP in 19 different types of FGIs was analyzed in both periods for two experienced interventional radiologists combined as well as individually. Patient dose and occupational dose were correlated, applying Pearson and Spearman correlation coefficients. Although FGIs were similar in numbers and types over both periods, a substantial decrease was found for period 2 in total mean ± SD/median KAP for both operators together (period 1, 47 Gy ∙ cm(2) ± 67/41 Gy ∙ cm(2); period 2, 37 Gy ∙ cm(2) ± 69/34 Gy ∙ cm(2)) as well as for each individual operator (for all, P < .05). Overall, KAP declined considerably in 15 of 19 types of FGIs in period 2. Mean accumulated dose per intervention was 4.6 µSv, and mean dose rate was 0.24 mSv/h. There was a strong positive correlation between patient and occupational dose (r = 0.88). Combined use of a patient dose monitoring system and a real-time occupational dose monitoring system in FGIs significantly lessens patient and operator doses. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  10. Home blood sodium monitoring, sliding-scale fluid prescription and subcutaneous DDAVP for infantile diabetes insipidus with impaired thirst mechanism.

    PubMed

    Hameed, Shihab; Mendoza-Cruz, Abel C; Neville, Kristen A; Woodhead, Helen J; Walker, Jan L; Verge, Charles F

    2012-06-09

    Infants with diabetes insipidus (DI), especially those with impaired thirst mechanism or hypothalamic hyperphagia, are prone to severe sodium fluctuations, often requiring hospitalization. We aimed to avoid dangerous fluctuations in serum sodium and improve parental independence. A 16-month old girl with central DI, absent thirst mechanism and hyperphagia following surgery for hypothalamic astrocytoma had erratic absorption of oral DDAVP during chemotherapy cycles. She required prolonged hospitalizations for hypernatremia and hyponatremic seizure. Intensive monitoring of fluid balance, weight and clinical assessment of hydration were not helpful in predicting serum sodium. Discharge home was deemed unsafe. Oral DDAVP was switched to subcutaneous (twice-daily injections, starting with 0.01mcg/dose, increasing to 0.024mcg/dose). The parents adjusted daily fluid allocation by sliding-scale, according to the blood sodium level (measured by handheld i-STAT analyser, Abbott). We adjusted the DDAVP dose if fluid allocation differed from maintenance requirements for 3 consecutive days. After 2.5 months, sodium was better controlled, with 84% of levels within reference range (135-145 mmol/L) vs. only 51% on the old regimen (p = 0.0001). The sodium ranged from 132-154 mmol/L, compared to 120-156 on the old regimen. She was discharged home. This practical regimen improved sodium control, parental independence, and allowed discharge home.

  11. Home blood sodium monitoring, sliding-scale fluid prescription and subcutaneous DDAVP for infantile diabetes insipidus with impaired thirst mechanism

    PubMed Central

    2012-01-01

    Background/Aims Infants with diabetes insipidus (DI), especially those with impaired thirst mechanism or hypothalamic hyperphagia, are prone to severe sodium fluctuations, often requiring hospitalization. We aimed to avoid dangerous fluctuations in serum sodium and improve parental independence. Methods A 16-month old girl with central DI, absent thirst mechanism and hyperphagia following surgery for hypothalamic astrocytoma had erratic absorption of oral DDAVP during chemotherapy cycles. She required prolonged hospitalizations for hypernatremia and hyponatremic seizure. Intensive monitoring of fluid balance, weight and clinical assessment of hydration were not helpful in predicting serum sodium. Discharge home was deemed unsafe. Oral DDAVP was switched to subcutaneous (twice-daily injections, starting with 0.01mcg/dose, increasing to 0.024mcg/dose). The parents adjusted daily fluid allocation by sliding-scale, according to the blood sodium level (measured by handheld i-STAT analyser, Abbott). We adjusted the DDAVP dose if fluid allocation differed from maintenance requirements for 3 consecutive days. Results After 2.5 months, sodium was better controlled, with 84% of levels within reference range (135-145 mmol/L) vs. only 51% on the old regimen (p = 0.0001). The sodium ranged from 132-154 mmol/L, compared to 120–156 on the old regimen. She was discharged home. Conclusion This practical regimen improved sodium control, parental independence, and allowed discharge home. PMID:22682315

  12. 2007 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2008-04-09

    During the 2007 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection and technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2007, there were 172 person-trips that required dose monitoring of the U.S. monitors. Of the 172 person-trips, 160 person-trips were SMVs and 12 person-trips were Transparency Monitoring Office (TMO) trips. There were 12 monitoring visits by TMO monitors to facilities other than UEIE and 10 to UEIE itself. There were two monitoring visits (sourcemore » changes) that were back to back with 14 monitors. LLNL's Hazard Control Division laboratories provided the dosimetry services for the HEU Transparency monitors.« less

  13. Real-time eye lens dose monitoring during cerebral angiography procedures.

    PubMed

    Safari, M J; Wong, J H D; Kadir, K A A; Thorpe, N K; Cutajar, D L; Petasecca, M; Lerch, M L F; Rosenfeld, A B; Ng, K H

    2016-01-01

    To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

  14. Dose optimization of total or partial skin electron irradiation by thermoluminescent dosimetry.

    PubMed

    Schüttrumpf, Lars; Neumaier, Klement; Maihoefer, Cornelius; Niyazi, Maximilian; Ganswindt, Ute; Li, Minglun; Lang, Peter; Reiner, Michael; Belka, Claus; Corradini, Stefanie

    2018-05-01

    Due to the complex surface of the human body, total or partial skin irradiation using large electron fields is challenging. The aim of the present study was to quantify the magnitude of dose optimization required after the application of standard fields. Total skin electron irradiation (TSEI) was applied using the Stanford technique with six dual-fields. Patients presenting with localized lesions were treated with partial skin electron irradiation (PSEI) using large electron fields, which were individually adapted. In order to verify and validate the dose distribution, in vivo dosimetry with thermoluminescent dosimeters (TLD) was performed during the first treatment fraction to detect potential dose heterogeneity and to allow for an individual dose optimization with adjustment of the monitor units (MU). Between 1984 and 2017, a total of 58 patients were treated: 31 patients received TSEI using 12 treatment fields, while 27 patients underwent PSEI and were treated with 4-8 treatment fields. After evaluation of the dosimetric results, an individual dose optimization was necessary in 21 patients. Of these, 7 patients received TSEI (7/31). Monitor units (MU) needed to be corrected by a mean value of 117 MU (±105, range 18-290) uniformly for all 12 treatment fields, corresponding to a mean relative change of 12% of the prescribed MU. In comparison, the other 14 patients received PSEI (14/27) and the mean adjustment of monitor units was 282 MU (±144, range 59-500) to single or multiple fields, corresponding to a mean relative change of 22% of the prescribed MU. A second dose optimization to obtain a satisfying dose at the prescription point was need in 5 patients. Thermoluminescent dosimetry allows an individual dose optimization in TSEI and PSEI to enable a reliable adjustment of the MUs to obtain the prescription dose. Especially in PSEI in vivo dosimetry is of fundamental importance.

  15. Do Asian renal transplant patients need another mycophenolate mofetil dose compared with Caucasian or African American patients?

    PubMed

    Li, Pengmei; Shuker, Nauras; Hesselink, Dennis A; van Schaik, Ron H N; Zhang, Xianglin; van Gelder, Teun

    2014-10-01

    Mycophenolate mofetil (MMF) is used to prevent acute rejection following solid organ transplantation in transplant centers all over the world. Patients from different ethnic backgrounds are treated with this drug, for which therapeutic drug monitoring (TDM) has not become the standard of practice in most centers. Whether or not some ethnic groups require a different MMF dose has been a topic of debate in recent years. In this review, it is shown that Asian patients, compared with Caucasian patients, with a comparable MMF dose reach higher mycophenolic acid (MPA) exposure. Also clinical experience points toward more adverse events in case of treatment with 1 g MMF bid in Asian patients, and therefore, for this ethnic group, a lower maintenance dose seems justified. In contrast, African American patients reach similar drug concentrations as Caucasians patients receiving the same MMF dose, but due to immunological reasons, they require a higher MMF dose to reach comparable acute rejection incidences. When TDM is performed, clinicians can correct the dose and compensate for interethnic differences in drug exposure. Otherwise, it is important to choose the right dose. This optimal dose is 20-46% lower in Asian transplant recipients than in Caucasian or African American patients. © 2014 Steunstichting ESOT.

  16. DATA REQUIREMENTS FOR ASSESSING CHILDREN'S EXPOSURE TO PESTICIDES

    EPA Science Inventory

    Several multimedia, multipathway exposure monitoring studies are currently being planned within EPA/NERL. The overall objectives of these studies are (1) to develop the data and models that can be used to estimate exposure and dose for young children to pesticides and (2) to i...

  17. Visual Indicators on Vaccine Boxes as Early Warning Tools to Identify Potential Freeze Damage.

    PubMed

    Angoff, Ronald; Wood, Jillian; Chernock, Maria C; Tipping, Diane

    2015-07-01

    The aim of this study was to determine whether the use of visual freeze indicators on vaccines would assist health care providers in identifying vaccines that may have been exposed to potentially damaging temperatures. Twenty-seven sites in Connecticut involved in the Vaccine for Children Program participated. In addition to standard procedures, visual freeze indicators (FREEZEmarker ® L; Temptime Corporation, Morris Plains, NJ) were affixed to each box of vaccine that required refrigeration but must not be frozen. Temperatures were monitored twice daily. During the 24 weeks, all 27 sites experienced triggered visual freeze indicator events in 40 of the 45 refrigerators. A total of 66 triggered freeze indicator events occurred in all 4 types of refrigerators used. Only 1 of the freeze events was identified by a temperature-monitoring device. Temperatures recorded on vaccine data logs before freeze indicator events were within the 35°F to 46°F (2°C to 8°C) range in all but 1 instance. A total of 46,954 doses of freeze-sensitive vaccine were stored at the time of a visual freeze indicator event. Triggered visual freeze indicators were found on boxes containing 6566 doses (14.0% of total doses). Of all doses stored, 14,323 doses (30.5%) were of highly freeze-sensitive vaccine; 1789 of these doses (12.5%) had triggered indicators on the boxes. Visual freeze indicators are useful in the early identification of freeze events involving vaccines. Consideration should be given to including these devices as a component of the temperature-monitoring system for vaccines.

  18. Evaluation of Accuracy of Six Blood Glucose Monitoring Systems and Modeling of Possibly Related Insulin Dosing Errors.

    PubMed

    Baumstark, Annette; Jendrike, Nina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2017-10-01

    Self-monitoring of blood glucose (BG) is an essential part of diabetes therapy. Accurate and reliable results from BG monitoring systems (BGMS) are important especially when they are used to calculate insulin doses. This study aimed at assessing system accuracy of BGMS and possibly related insulin dosing errors. System accuracy of six different BGMS (Accu-Chek ® Aviva Nano, Accu-Chek Mobile, Accu-Chek Performa Nano, CONTOUR ® NEXT LINK 2.4, FreeStyle Lite, OneTouch ® Verio ® IQ) was assessed in comparison to a glucose oxidase and a hexokinase method. Study procedures and analysis were based on ISO 15197:2013/EN ISO 15197:2015, clause 6.3. In addition, insulin dosing error was modeled. In the comparison against the glucose oxidase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 14.3%/4.3%/0.3% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U and missing the modeled target by 20 mg/dL/40 mg/dL/60 mg/dL, respectively. Compared against the hexokinase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 25.0%/10.5%/3.2% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U, respectively. Differences in system accuracy were found, even among BGMS that fulfilled the minimum system accuracy criteria of ISO 15197:2013. In the error model, considerable insulin dosing errors resulted for some of the investigated systems. Diabetes patients on insulin therapy should be able to rely on their BGMS' readings; therefore, they require highly accurate BGMS, in particular, when making therapeutic decisions.

  19. Some computer graphical user interfaces in radiation therapy

    PubMed Central

    Chow, James C L

    2016-01-01

    In this review, five graphical user interfaces (GUIs) used in radiation therapy practices and researches are introduced. They are: (1) the treatment time calculator, superficial X-ray treatment time calculator (SUPCALC) used in the superficial X-ray radiation therapy; (2) the monitor unit calculator, electron monitor unit calculator (EMUC) used in the electron radiation therapy; (3) the multileaf collimator machine file creator, sliding window intensity modulated radiotherapy (SWIMRT) used in generating fluence map for research and quality assurance in intensity modulated radiation therapy; (4) the treatment planning system, DOSCTP used in the calculation of 3D dose distribution using Monte Carlo simulation; and (5) the monitor unit calculator, photon beam monitor unit calculator (PMUC) used in photon beam radiation therapy. One common issue of these GUIs is that all user-friendly interfaces are linked to complex formulas and algorithms based on various theories, which do not have to be understood and noted by the user. In that case, user only needs to input the required information with help from graphical elements in order to produce desired results. SUPCALC is a superficial radiation treatment time calculator using the GUI technique to provide a convenient way for radiation therapist to calculate the treatment time, and keep a record for the skin cancer patient. EMUC is an electron monitor unit calculator for electron radiation therapy. Instead of doing hand calculation according to pre-determined dosimetric tables, clinical user needs only to input the required drawing of electron field in computer graphical file format, prescription dose, and beam parameters to EMUC to calculate the required monitor unit for the electron beam treatment. EMUC is based on a semi-experimental theory of sector-integration algorithm. SWIMRT is a multileaf collimator machine file creator to generate a fluence map produced by a medical linear accelerator. This machine file controls the multileaf collimator to deliver intensity modulated beams for a specific fluence map used in quality assurance or research. DOSCTP is a treatment planning system using the computed tomography images. Radiation beams (photon or electron) with different energies and field sizes produced by a linear accelerator can be placed in different positions to irradiate the tumour in the patient. DOSCTP is linked to a Monte Carlo simulation engine using the EGSnrc-based code, so that 3D dose distribution can be determined accurately for radiation therapy. Moreover, DOSCTP can be used for treatment planning of patient or small animal. PMUC is a GUI for calculation of the monitor unit based on the prescription dose of patient in photon beam radiation therapy. The calculation is based on dose corrections in changes of photon beam energy, treatment depth, field size, jaw position, beam axis, treatment distance and beam modifiers. All GUIs mentioned in this review were written either by the Microsoft Visual Basic.net or a MATLAB GUI development tool called GUIDE. In addition, all GUIs were verified and tested using measurements to ensure their accuracies were up to clinical acceptable levels for implementations. PMID:27027225

  20. Effective biological dose from occupational exposure during nanoparticle synthesis

    NASA Astrophysics Data System (ADS)

    Demou, Evangelia; Tran, Lang; Housiadas, Christos

    2009-02-01

    Nanomaterial and nanotechnology safety require the characterization of occupational exposure levels for completing a risk assessment. However, equally important is the estimation of the effective internal dose via lung deposition, transport and clearance mechanisms. An integrated source-to-biological dose assessment study is presented using real monitoring data collected during nanoparticle synthesis. Experimental monitoring data of airborne exposure levels during nanoparticle synthesis of CaSO4 and BiPO4 nanoparticles in a research laboratory is coupled with a human lung transport and deposition model, which solves in an Eulerian framework the general dynamic equation for polydisperse aerosols using particle specific physical-chemical properties. Subsequently, the lung deposition model is coupled with a mathematical particle clearance model providing the effective biological dose as well as the time course of the biological dose build-up after exposure. The results for the example of BiPO4 demonstrate that even short exposures throughout the day can lead to particle doses of 1.10·E+08#/(kg-bw·8h-shift), with the majority accumulating in the pulmonary region. Clearance of particles is slow and is not completed within a working shift following a 1 hour exposure. It mostly occurs via macrophage activity in the alveolar region, with small amounts transported to the interstitium and less to the lymph nodes.

  1. A Dose-Response Study of Inactivated Low Pathogenic Avian Influenza H9N2 Virus in Specific-Pathogen-Free and Commercial Broiler Chickens.

    PubMed

    Kilany, Walid H; Ali, Ahmed; Bazid, Abdel-Hamid I; El-Deeb, Ayman H; El-Abideen, Mohamed A Zain; Sayed, Magdy El; El-Kady, Magdy F

    2016-05-01

    Since the first report of low pathogenic avian influenza (LPAI) H9N2 virus in Egypt in 2011, the Egyptian poultry industry has suffered from unexpected economic losses as a result of the wide spread of LPAI H9N2. Hence, inactivated H9N2 vaccines have been included in the vaccination programs of different poultry production sectors. The optimal antigen content of avian influenza virus vaccines is essential to reach protective antibody titers. In this study, the correlation between antigen content (based on hemagglutinating units [HAU]) and postvaccination (PV) antibody response of H9N2 inactivated vaccine was studied. Five different vaccine antigen loads (128, 200, 250, 300, and 350 HAU formulas/dose) were investigated in commercial broiler and specific-pathogen-free (SPF) chickens. Vaccine safety and PV antibody responses were monitored. At the fourth week PV only SPF vaccinated groups (128, 200, 250, and 300 HAU/dose) were challenged using LPAI H9N2 (A/Ck/EG/114940v/NLQP/11) virus with 10(6) EID50/bird. Oropharyngeal swabs were used to monitor virus shedding at 2, 4, 6, and 10 days postchallenge. Results showed that all vaccine formulations were well tolerated, and the highest antibody titers were observed in birds vaccinated with higher HAU. Vaccines containing 128 and 200 HAU/dose did not induce the required protective HI titers by 3 wk PV. Meanwhile, the challenge experiment in SPF chickens showed that 250 and 300 HAU vaccine doses were required to reduce the level and duration of virus shedding. Study results thus suggest that inactivated H9N2 vaccines containing at least 250 HAU/dose will induce the optimal protective titers and minimize virus shedding in SPF chickens.

  2. Evaluation of the Pharmacokinetics and Efficacy of a Busulfan Test Dose in Adult Patients Undergoing Myeloablative Hematopoietic Cell Transplantation.

    PubMed

    Weil, Elizabeth; Zook, Felicia; Oxencis, Carolyn; Canadeo, Angela; Urmanski, Angela; Waggoner, Mindy; Eastwood, Daniel; Pasquini, Marcelo; Hamadani, Mehdi; Hari, Parameswaran

    2017-06-01

    Owing to interpatient variability in busulfan exposure, therapeutic monitoring of busulfan is often used in myeloablative allogeneic transplantation to ensure that patients are near the optimal steady-state goal of 900 ng/mL. One challenge in therapeutic monitoring of busulfan is the brief course of busulfan treatment, requiring prompt analysis and dose adjustments as needed. Pharmacokinetic evaluation of a busulfan test dose before the start of the conditioning regimen would allow for all conditioning regimen doses to be given at the calculated optimized dose. An observational study was completed to evaluate the effects of a busulfan test dose of 0.9 mg/kg administered before the start of a myeloablative intravenous busulfan-based conditioning regimen. Sixty adult patients who received a busulfan conditioning regimen were reviewed, including 30 patients prior to the implementation of the busulfan test dose (pretest dose group) and 30 patients who received the busulfan test dose (posttest dose group). The primary objective was a pharmacokinetic evaluation of the percentage of patients who achieved the desired steady-state goal using the test dose strategy. The safety and efficacy of the busulfan test dose were evaluated as well. The average busulfan steady-state level after the first dose of the conditioning regimen was significantly lower in the pre-test dose group compared with the post-test dose group (660 ng/mL versus 879.9 ng/mL; P < 0.001). Compared with the post-test dose group, significantly fewer patients in the pre-test dose group were within 10% of the busulfan steady-state goal (10% versus 73.3%; P < 0.001) or within 5% of the goal (0% versus 53%; P < 0.001). Requirements for parenteral nutrition and/or patient-controlled analgesia owing to mucositis and rates of veno-occlusive disease were not significantly different between the pre-test dose group and the post-test dose group. The rates of disease relapse, mortality, and acute graft-versus-host disease were similar in the two groups. A pretransplantation busulfan test dose of 0.9 mg/kg improved the patients' ability to reach therapeutic busulfan target levels after the first conditioning dose and resulted in fewer adjustments during conditioning. The use of a busulfan test dose did not significantly increase patients' risk of mucositis or other safety outcomes. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Space Station Freedom Environmental Health Care Program

    NASA Technical Reports Server (NTRS)

    Richard, Elizabeth E.; Russo, Dane M.

    1992-01-01

    The paper discusses the environmental planning and monitoring aspects of the Space Station Freedom (SSF) Environmental Health Care Program, which encompasses all phases of the SSF assembly and operation from the first element entry at MB-6 through the Permanent Manned Capability and beyond. Environmental planning involves the definition of acceptability limits and monitoring requirements for the radiation dose barothermal parameters and potential contaminants in the SSF air and water and on internal surfaces. Inflight monitoring will be implemented through the Environmental Health System, which consists of five subsystems: Microbiology, Toxicology, Water Quality, Radiation, and Barothermal Physiology. In addition to the environmental data interpretation and analysis conducted after each mission, the new data will be compared to archived data for statistical and long-term trend analysis and determination of risk exposures. Results of these analyses will be used to modify the acceptability limits and monitoring requirements for the future.

  4. Radiology metrics for safe use and regulatory compliance with CT imaging

    NASA Astrophysics Data System (ADS)

    Paden, Robert; Pavlicek, William

    2018-03-01

    The MACRA Act creates a Merit-Based Payment System, with monitoring patient exposure from CT providing one possible quality metric for meeting merit requirements. Quality metrics are also required by The Joint Commission, ACR, and CMS as facilities are tasked to perform reviews of CT irradiation events outside of expected ranges, review protocols for appropriateness, and validate parameters for low dose lung cancer screening. In order to efficiently collect and analyze irradiation events and associated DICOM tags, all clinical CT devices were DICOM connected to a parser which extracted dose related information for storage into a database. Dose data from every exam is compared to the appropriate external standard exam type. AAPM recommended CTDIvol values for head and torso, adult and pediatrics, coronary and perfusion exams are used for this study. CT doses outside the expected range were automatically formatted into a report for analysis and review documentation. CT Technologist textual content, the reason for proceeding with an irradiation above the recommended threshold, is captured for inclusion in the follow up reviews by physics staff. The use of a knowledge based approach in labeling individual protocol and device settings is a practical solution resulting in efficiency of analysis and review. Manual methods would require approximately 150 person-hours for our facility, exclusive of travel time and independent of device availability. An efficiency of 89% time savings occurs through use of this informatics tool including a low dose CT comparison review and low dose lung cancer screening requirements set forth by CMS.

  5. Intermittent preventive treatment of malaria during pregnancy in central Mozambique.

    PubMed

    Brentlinger, Paula E; Dgedge, Martinho; Correia, Maria Ana Chadreque; Rojas, Ana Judith Blanco; Saúte, Francisco; Gimbel-Sherr, Kenneth H; Stubbs, Benjamin A; Mercer, Mary Anne; Gloyd, Stephen

    2007-11-01

    New WHO strategies for control of malaria in pregnancy (MiP) recommend intermittent preventive treatment (IPTp), bednet use and improved case management. A pilot MiP programme in Mozambique was designed to determine requirements for scale-up. The Ministry of Health worked with a nongovernmental organization and an academic institution to establish and monitor a pilot programme in two impoverished malaria-endemic districts. Implementing the pilot programme required provision of additional sulfadoxine-pyrimethamine (SP), materials for directly observed SP administration, bednets and a modified antenatal card. National-level formulary restrictions on SP needed to be waived. The original protocol required modification because imprecision in estimation of gestational age led to missed SP doses. Multiple incompatibilities with other health initiatives (including programmes for control of syphilis, anaemia and HIV) were discovered and overcome. Key outputs and impacts were measured; 92.5% of 7911 women received at least 1 dose of SP, with the mean number of SP doses received being 2.2. At the second antenatal visit, 13.5% of women used bednets. In subgroups (1167 for laboratory analyses; 2600 births), SP use was significantly associated with higher haemoglobin levels (10.9 g/dL if 3 doses, 10.3 if none), less malaria parasitaemia (prevalence 7.5% if 3 doses, 39.3% if none), and fewer low-birth-weight infants (7.3% if 3 doses, 12.5% if none). National-level scale-up will require attention to staffing, supplies, bednet availability, drug policy, gestational-age estimation and harmonization of vertical initiatives.

  6. Segmented-field radiography in scoliosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel, W.W.; Barnes, G.T.; Nasca, R.J.

    1985-02-01

    A method of scoliosis imaging using segmented fields is presented. The method is advantageous for patients requiring serial radiographic monitoring, as it results in markedly reduced radiation doses to critical organs, particularly the breast. Absorbed dose to the breast was measured to be 8.8 mrad (88 ..mu..Gy) for a full-field examination and 0.051 mrad (5.1 ..mu..Gy) for the segmented-field study. The segmented-field technique also results in improved image quality. Experience with 53 studies in 23 patients is reported.

  7. Results of space environment measurement carried out by the Roscosmos monitoring system elements and their correlation with different space weather characteristics

    NASA Astrophysics Data System (ADS)

    Protopopov, Grigory; Anashin, Vasily; Elushov, Ilya; Kozyukova, Olga

    The Monitoring System of space radiation exposure on electronic components is developed by the Institute of Space Device Engineering by order Roscosmos. The key targets of the Monitoring System are space environment measurements, space model correction, space weather characteristics forecast, improvement of radiation hardness technical requirements and etc. The Monitoring System includes two parts: the ground-based and the space-born segments. The ground-based segment includes the forecast station, the analytic complex and the data output system. The space-born segment base elements are TID sensors operating by MNOSFET dosimetry principle. Sensor temperature stabilization is achieved by choosing of operational point according to the minimal change of sensor current-voltage curve. The set of 38 TID sensors is placed on 19 spacecrafts currently. The spacecrafts operate in Medium Earth Orbit (MEO) (approximately 20 000 km with inclination of 65(°) ). The flight data obtained perfectly correlate with total dose flight data registered using MOSFET placed on Van Allen Probe spacecraft functioning in high elliptical orbit (apogee is 37 000 km, perigee is 650 km, inclination is 10(°) ). Also coincidence with the dose data from GIOVE-B spacecraft (circular orbit 23200 km, inclination of 56(°) ) of Galileo system is observed. We have observed several abrupt dose rate increases from April, 2010. The flight data are compared with other monitoring system data and ground measurements. The comparison results show that high energy electrons (> 1 MeV) give general contribution in accumulated dose and anomalous dose rate increases. These results are in agreement with shielding stopping power calculation results. The high electron fluxes rise significantly in MEO as a result of Van Allen belts shifting during geomagnetic storms. The flight data were compared with calculation results obtained using different space models. The comparison shows that for some long-term interval the distinction between experimental and calculated results can be 7 times less or more.

  8. INTERCOMPARISON ON THE MEASUREMENT OF THE QUANTITY PERSONAL DOSE EQUIVALENT HP(10) IN PHOTON FIELDS. LINEARITY DEPENDENCE, LOWER LIMIT OF DETECTION AND UNCERTAINTY IN MEASUREMENT OF DOSIMETRY SYSTEMS OF INDIVIDUAL MONITORING SERVICES IN GABON AND GHANA.

    PubMed

    Ondo Meye, P; Schandorf, C; Amoako, J K; Manteaw, P O; Amoatey, E A; Adjei, D N

    2017-12-01

    An inter-comparison study was conducted to assess the capability of dosimetry systems of individual monitoring services (IMSs) in Gabon and Ghana to measure personal dose equivalent Hp(10) in photon fields. The performance indicators assessed were the lower limit of detection, linearity and uncertainty in measurement. Monthly and quarterly recording levels were proposed with corresponding values of 0.08 and 0.025 mSv, and 0.05 and 0.15 mSv for the TLD and OSL systems, respectively. The linearity dependence of the dosimetry systems was performed following the requirement given in the Standard IEC 62387 of the International Electrotechnical Commission (IEC). The results obtained for the two systems were satisfactory. The procedure followed for the uncertainty assessment is the one given in the IEC technical report TR62461. The maximum relative overall uncertainties, in absolute value, expressed in terms of Hp(10), for the TL dosimetry system Harshaw 6600, are 44. 35% for true doses below 0.40 mSv and 36.33% for true doses ≥0.40 mSv. For the OSL dosimetry system microStar, the maximum relative overall uncertainties, in absolute value, are 52.17% for true doses below 0.40 mSv and 37.43% for true doses ≥0.40 mSv. These results are in good agreement with the requirements for accuracy of the International Commission on Radiological protection. When expressing the uncertainties in terms of response, comparison with the IAEA requirements for overall accuracy showed that the uncertainty results were also acceptable. The values of Hp(10) directly measured by the two dosimetry systems showed a significant underestimation for the Harshaw 6600 system, and a slight overestimation for the microStar system. After correction for linearity of the measured doses, the two dosimetry systems gave better and comparable results. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  10. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  11. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  12. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  13. 10 CFR 36.55 - Personnel monitoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators... accident dose ranges (see 10 CFR 20.1501(c)). Each personnel dosimeter must be assigned to and worn by only... processed at least quarterly. (b) Other individuals who enter the radiation room of a panoramic irradiator...

  14. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device.

    PubMed

    Kavuma, Awusi; Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2010-01-21

    In vivo dosimetry is one of the quality assurance tools used in radiotherapy to monitor the dose delivered to the patient. Electronic portal imaging device (EPID) images for a set of solid water phantoms of varying thicknesses were acquired and the data fitted onto a quadratic equation, which relates the reduction in photon beam intensity to the attenuation coefficient and material thickness at a reference condition. The quadratic model is used to convert the measured grey scale value into water equivalent path length (EPL) at each pixel for any material imaged by the detector. For any other non-reference conditions, scatter, field size and MU variation effects on the image were corrected by relative measurements using an ionization chamber and an EPID. The 2D EPL is linked to the percentage exit dose table, for different thicknesses and field sizes, thereby converting the plane pixel values at each point into a 2D dose map. The off-axis ratio is corrected using envelope and boundary profiles generated from the treatment planning system (TPS). The method requires field size, monitor unit and source-to-surface distance (SSD) as clinical input parameters to predict the exit dose, which is then used to determine the entrance dose. The measured pixel dose maps were compared with calculated doses from TPS for both entrance and exit depth of phantom. The gamma index at 3% dose difference (DD) and 3 mm distance to agreement (DTA) resulted in an average of 97% passing for the square fields of 5, 10, 15 and 20 cm. The exit dose EPID dose distributions predicted by the algorithm were in better agreement with TPS-calculated doses than phantom entrance dose distributions.

  15. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    NASA Astrophysics Data System (ADS)

    Kavuma, Awusi; Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2010-01-01

    In vivo dosimetry is one of the quality assurance tools used in radiotherapy to monitor the dose delivered to the patient. Electronic portal imaging device (EPID) images for a set of solid water phantoms of varying thicknesses were acquired and the data fitted onto a quadratic equation, which relates the reduction in photon beam intensity to the attenuation coefficient and material thickness at a reference condition. The quadratic model is used to convert the measured grey scale value into water equivalent path length (EPL) at each pixel for any material imaged by the detector. For any other non-reference conditions, scatter, field size and MU variation effects on the image were corrected by relative measurements using an ionization chamber and an EPID. The 2D EPL is linked to the percentage exit dose table, for different thicknesses and field sizes, thereby converting the plane pixel values at each point into a 2D dose map. The off-axis ratio is corrected using envelope and boundary profiles generated from the treatment planning system (TPS). The method requires field size, monitor unit and source-to-surface distance (SSD) as clinical input parameters to predict the exit dose, which is then used to determine the entrance dose. The measured pixel dose maps were compared with calculated doses from TPS for both entrance and exit depth of phantom. The gamma index at 3% dose difference (DD) and 3 mm distance to agreement (DTA) resulted in an average of 97% passing for the square fields of 5, 10, 15 and 20 cm. The exit dose EPID dose distributions predicted by the algorithm were in better agreement with TPS-calculated doses than phantom entrance dose distributions.

  16. Sedation and monitoring for gastrointestinal endoscopy

    PubMed Central

    Amornyotin, Somchai

    2013-01-01

    The safe sedation of patients for diagnostic or therapeutic procedures requires a combination of properly trained physicians and suitable facilities. Additionally, appropriate selection and preparation of patients, suitable sedative technique, application of drugs, adequate monitoring, and proper recovery of patients is essential. The goal of procedural sedation is the safe and effective control of pain and anxiety as well as to provide an appropriate degree of memory loss or decreased awareness. Sedation practices for gastrointestinal endoscopy (GIE) vary widely. The majority of GIE patients are ambulatory cases. Most of this procedure requires a short time. So, short acting, rapid onset drugs with little adverse effects and improved safety profiles are commonly used. The present review focuses on commonly used regimens and monitoring practices in GIE sedation. This article is to discuss the decision making process used to determine appropriate pre-sedation assessment, monitoring, drug selection, dose of sedative agents, sedation endpoint and post-sedation care. It also reviews the current status of sedation and monitoring for GIE procedures in Thailand. PMID:23424050

  17. Effectiveness of a management program for outpatient clinic or remote titration of beta-blockers in CRT patients: The RESTORE study.

    PubMed

    D'Onofrio, Antonio; Palmisano, Pietro; Rapacciuolo, Antonio; Ammendola, Ernesto; Calò, Leonardo; Ruocco, Antonio; Bianchi, Valter; Maresca, Fabio; Del Giorno, Giuseppe; Martino, Annamaria; Mauro, Ciro; Campari, Monica; Valsecchi, Sergio; Accogli, Michele

    2017-06-01

    Many patients fail to receive β-blockers before cardiac resynchronization therapy defibrillator (CRT-D) implantation, or receive them at a suboptimal dose, and require optimization after implantation. We assessed the effectiveness of a structured program for β-blocker titration in CRT-D patients followed up by means of conventional in-clinic visits or remote monitoring. 130 patients undergoing CRT implantation and treated according to the standard practice of the centers were included as a control group. A second group of 124 CRT-D candidates (Study Group) underwent up-titration visits every 2weeks after implantation (target dose: 10mg/day of bisoprolol or 50mg/day of carvedilol). In the Study Group, remote monitoring was undertaken in 66 patients, who received additional equipment for daily transmission of weight and blood pressure data, and scheduled titration telephone calls. In the Control Group, the maximal dose of β-blockers was being administered to 12 (9%) patients on implantation and 21 (16%) on 6-month follow-up examination (p>0.05). In the Study Group, 25 (20%) patients were receiving the maximal dose of β-blockers on implantation and 72 (58%) on follow-up examination (p<0.001). The 66 Study Group patients on remote monitoring underwent fewer in-clinic visits (p=0.034). Of these, 50 (76%) were on the maximal dose after remote up-titration (versus 38% of patients followed up conventionally, p<0.001). The decrease in left ventricular end-systolic volume was larger in the Study Group (p=0.040). The program for β-blocker up-titration increased the number of patients reaching the target dose and improved the response to the therapy. The use of remote monitoring and daily transfer of weight and blood pressure data facilitated β-blocker titration. URL: http://clinicaltrials.gov/ Identifier: NCT02173028. Copyright © 2017. Published by Elsevier B.V.

  18. 2004 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2005-04-01

    During the 2004 calendar year, LLNL provided health physics support for the Highly Enriched Uranium Transparency Implementation Program (HEU-TIP) in external and internal radiation protection and technical expertise into matters related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2004, there were 200 person-trips that required dose monitoring of the U.S. monitors. Of the 200 person-trips, 183 person-trips were SMVs and 17 person-trips were Transparency Monitoring Office (TMO) trips. Eight person-trips from the SMV trips were continuation trips of TMO monitors to facilities other than UEIP. The LLNL Safety Laboratories' Division provided the dosimetrymore » services for the HEU-TIP monitors.« less

  19. Perioperative Management of the Adult Patient on Venovenous Extracorporeal Membrane Oxygenation Requiring Noncardiac Surgery.

    PubMed

    Fierro, Michael A; Daneshmand, Mani A; Bartz, Raquel R

    2018-01-01

    The use of venovenous extracorporeal membrane oxygenation is increasing worldwide. These patients often require noncardiac surgery. In the perioperative period, preoperative assessment, patient transport, choice of anesthetic type, drug dosing, patient monitoring, and intraoperative and postoperative management of common patient problems will be impacted. Furthermore, common monitoring techniques will have unique limitations. Importantly, patients on venovenous extracorporeal membrane oxygenation remain subject to hypoxemia, hypercarbia, and acidemia in the perioperative setting despite extracorporeal support. Treatments of these conditions often require both manipulation of extracorporeal membrane oxygenation settings and physiologic interventions. Perioperative management of anticoagulation, as well as thresholds to transfuse blood products, remain highly controversial and must take into account the specific procedure, extracorporeal membrane oxygenation circuit function, and patient comorbidities. We will review the physiologic management of the patient requiring surgery while on venovenous extracorporeal membrane oxygenation.

  20. 2010 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, Radoslav

    2011-05-16

    During the 2010 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2010, there were 141 person-trips that required dose monitoring of the U.S. monitors. Of the 141 person-trips, 129 person-trips were Special Monitoring Visits (SMVs) and 12 person-trips were Transparency Monitoring Office (TMO) trips. In 8 of these TMO trips the TMO monitors participated also in the UEIE SMVs and in 2 TMOmore » trips the TMO monitors participated in UEIE and MPA SMVs. There were three monitoring visits (source changes) that were back-to-back SMVs with a total of 25 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors.« less

  1. Genetic polymorphisms are associated with variations in warfarin maintenance dose in Han Chinese patients with venous thromboembolism.

    PubMed

    Zhang, Wei; Zhang, Wei-Juan; Zhu, Jin; Kong, Fan-Cui; Li, Yan-Yan; Wang, He-Yao; Yang, Yuan-Hua; Wang, Chen

    2012-02-01

    Warfarin is a clinical anticoagulant that requires periodic monitoring because it is associated with adverse outcomes. Personalized medicine, which is based on pharmacogenetics, holds great promise in solving these types of problems. It aims to provide the tools and knowledge to tailor drug therapy to an individual patient, with the potential of increasing safety and efficacy of medications. In the present study we analyzed genotypes of 14 SNPs for seven genes using DNA from 297 Han Chinese venous thromboembolism patients treated with warfarin. Multiple regression analyses revealed that CYP2C9 genotype (p = 0.001), VKORC1 genotype (p < 0.001), age (p < 0.01) and weight (p < 0.001) were all associated with warfarin dose requirements, which can explain 37.4% of the variability of warfarin dose among Han Chinese patients. Meanwhile, in the validation cohort, the predicted warfarin daily dose was calculated using the best model with a 64.5% predicted dose being acceptable (-1 mg/day ≤Δwarfarin dose ≤1 mg/day). We developed a pharmacogenetic dose algorithm for warfarin treatment that uses genotypes from two genes (VKORC1 and CYP2C9) and clinical variables to predict therapeutic maintenance doses in Chinese patients with venous thromboembolism. The validity of the dosing algorithm was confirmed in a cohort of venous thromboembolism patients on warfarin therapy.

  2. On-line photolithography modeling using spectrophotometry and Prolith/2

    NASA Astrophysics Data System (ADS)

    Engstrom, Herbert L.; Beacham, Jeanne E.

    1994-05-01

    Spectrophotometry has been applied to optimizing photolithography processes in semiconductor manufacturing. For many years thin film measurement systems have been used in manufacturing for controlling film deposition processes. The combination of film thickness mapping with photolithography modeling has expanded the applications of this technology. Experimental measurements of dose-to-clear, the minimum light exposure dose required to fully develop a photoresist, are described. It is shown how dose-to-clear and photoresist contrast may be determined rapidly and conveniently from measurements of a dose exposure matrix on a monitor wafer. Such experimental measurements may underestimate the dose-to- clear because of thickness variations of the photoresist and underlying layers on the product wafer. Online modeling of the photolithographic process together with film thickness maps of the entire wafer can overcome this problem. Such modeling also provides maps of dose-to- clear and resist linewidth that can be used to estimate and optimize yield.

  3. The Mayak Worker Dosimetry System (MWDS-2013): Implementation of the Dose Calculations.

    PubMed

    Zhdanov, А; Vostrotin, V; Efimov, А; Birchall, A; Puncher, M

    2016-07-15

    The calculation of internal doses for the Mayak Worker Dosimetry System (MWDS-2013) involved extensive computational resources due to the complexity and sheer number of calculations required. The required output consisted of a set of 1000 hyper-realizations: each hyper-realization consists of a set (1 for each worker) of probability distributions of organ doses. This report describes the hardware components and computational approaches required to make the calculation tractable. Together with the software, this system is referred to here as the 'PANDORA system'. It is based on a commercial SQL server database in a series of six work stations. A complete run of the entire Mayak worker cohort entailed a huge amount of calculations in PANDORA and due to the relatively slow speed of writing the data into the SQL server, each run took about 47 days. Quality control was monitored by comparing doses calculated in PANDORA with those in a specially modified version of the commercial software 'IMBA Professional Plus'. Suggestions are also made for increasing calculation and storage efficiency for future dosimetry calculations using PANDORA. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Weldon Spring Site environmental report for calendar year 1993. Weldon Springs Site Remedial Action Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-05-01

    This Site Environmental Report for Calendar Year 1993 describes the environmental monitoring programs at the Weldon Spring Site Remedial Action Project (WSSRAP). The objectives of these programs are to assess actual or potential exposure to contaminant effluents from the project area by providing public use scenarios and dose estimates, to demonstrate compliance with Federal and State permitted levels, and to summarize trends and/or changes in contaminant concentrations from environmental monitoring program. In 1993, the maximum committed dose to a hypothetical individual at the chemical plant site perimeter was 0.03 mrem (0.0003 mSv). The maximum committed dose to a hypothetical individualmore » at the boundary of the Weldon Spring Quarry was 1.9 mrem (0.019 mSv). These scenarios assume an individual walking along the perimeter of the site-once a day at the chemical plant/raffinate pits and twice a day at the quarry-250 days per year. This hypothetical individual also consumes fish, sediment, and water from lakes and other bodies of water in the area. The collective dose, based on an effected population of 112,000 was 0.12 person-rem (0.0012 person-Sv). This calculation is based on recreational use of the August A. Busch Memorial Conservation Area and the Missouri Department of Conservation recreational trail (the Katy Trail) near the quarry. These estimates are below the U.S. Department of Energy requirement of 100 mrem (I mSv) annual committed effective dose equivalent for all exposure pathways. Results from air monitoring for the National Emission Standards for Hazardous Air Pollutants (NESHAPs) program indicated that the estimated dose was 0.38 mrem, which is below the U.S. Environmental Protection Agency (EPA) standard of 10 mrem per year.« less

  5. Do all patients in the phase I oncology trials need to be hospitalized? Domestic but outstanding issues for globalization of drug development in Japan.

    PubMed

    Shimomura, Akihiko; Kondo, Shunsuke; Kobayashi, Noriko; Iwasa, Satoru; Kitano, Shigehisa; Tamura, Kenji; Fujiwara, Yutaka; Yamamoto, Noboru

    2017-08-01

    Most trials investigating new drugs around the world, including phase I trials, are conducted in outpatient clinics. However, in Japan, regulatory authority requirements and traditional domestic guidelines often require hospitalization of phase I study participants. Patients participating in single-agent phase I clinical trials at National Cancer Center Hospital between December 1996 and August 2014 were monitored. Toxicity requiring hospitalization is defined as toxicity that needs intensive treatment. Study designs were classified into three types: first-in-human (FIH) study, dose-escalation study (conventional dose-escalation study to determine maximum tolerated dose (MTD) in Japanese patients), and dose-finding study (to assess safety and pharmacokinetic profiles up to the MTD previously determined in the West). A total of 945 patients who participated in a variety of single-agent phase I clinical trials between December 1996 and August 2014 were included in this study. Patients participated in one of three study types: dose-escalation (n = 582, 62%), first-in-human (n = 129, 14%), or dose-finding (n = 234, 25%). A total of 76 study drugs were evaluated as part of this pool of phase I studies. Subdivided by mechanism of action, 20 (26%) were cytotoxic, 50 (66%) were molecularly targeted, and 6 (8%) were immune checkpoint inhibitor. Thirty-six patients (3.8%) had severe toxicities requiring hospitalization during the first cycle. The overall number of toxicities requiring hospitalization and/or grade 4 toxicities during any cycle was 5.0%. The frequency of severe toxicity that needs to be hospitalized was unexpectedly low. The data did not demonstrate the need for hospitalization in the phase I trials, suggesting that phase I trials in Japan could be conducted in outpatient settings.

  6. Best practice for the pharmacological management of hyperthyroid cats with antithyroid drugs.

    PubMed

    Daminet, S; Kooistra, H S; Fracassi, F; Graham, P A; Hibbert, A; Lloret, A; Mooney, C T; Neiger, R; Rosenberg, D; Syme, H M; Villard, I; Williams, G

    2014-01-01

    Pharmacological management of feline hyperthyroidism offers a practical treatment option for many hyperthyroid cats. Two drugs have been licensed for cats in the last decade: methimazole and its pro-drug carbimazole. On the basis of current evidence and available tablet sizes, starting doses of 2·5 mg methimazole twice a day and 10 to 15 mg once a day for the sustained release formulation of carbimazole are recommended. These doses should then be titrated to effect in order to obtain circulating total thyroxine (TT4) concentrations in the lower half of the reference interval. Treated cases should be monitored for side-effects, especially during the first months of treatment. Some side-effects may require discontinuation of treatment. At each monitoring visit, clinical condition and quality of life should also be evaluated, with special attention to possible development of azotaemia, hypertension and iatrogenic hypothyroidism. When euthyroidism has been achieved, monitoring visits are recommended after 1 month, 3 months and biannually thereafter. Cats with pre-existing azotaemia have shorter survival times. However, development of mild azotaemia during the initial course of treatment, unless associated with hypothyroidism, does not appear to decrease survival time. The long-term effects of chronic medical management require further study. © 2013 British Small Animal Veterinary Association.

  7. Direct-Acting Oral Anticoagulants: Practical Considerations for Emergency Medicine Physicians

    PubMed Central

    Peacock, W. Frank; Rafique, Zubaid; Singer, Adam J.

    2016-01-01

    Nonvalvular atrial fibrillation- (NVAF-) related stroke and venous thromboembolism (VTE) are cardiovascular diseases associated with significant morbidity and economic burden. The historical standard treatment of VTE has been the administration of parenteral heparinoid until oral warfarin therapy attains a therapeutic international normalized ratio. Warfarin has been the most common medication for stroke prevention in NVAF. Warfarin use is complicated by a narrow therapeutic window, unpredictable dose response, numerous food and drug interactions, and requirements for frequent monitoring. To overcome these disadvantages, direct-acting oral anticoagulants (DOACs)—dabigatran, rivaroxaban, apixaban, and edoxaban—have been developed for the prevention of stroke or systemic embolic events (SEE) in patients with NVAF and for the treatment of VTE. Advantages of DOACs include predictable pharmacokinetics, few drug-drug interactions, and low monitoring requirements. In clinical studies, DOACs are noninferior to warfarin for the prevention of NVAF-related stroke and the treatment and prevention of VTE as well as postoperative knee and hip surgery VTE prophylaxis, with decreased bleeding risks. This review addresses the practical considerations for the emergency physician in DOAC use, including dosing recommendations, laboratory monitoring, anticoagulation reversal, and cost-effectiveness. The challenges of DOACs, such as the lack of specific laboratory measurements and antidotes, are also discussed. PMID:27293895

  8. 2005 Annual Health Physics Report for HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2006-04-21

    During the 2005 calendar year, LLNL provided health physics support for the Highly Enriched Uranium Transparency Program (HEU-TP) in external and internal radiation protection and technical expertise into matters related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2005, there were 161 person-trips that required dose monitoring of the U.S. monitors. Of the 161 person-trips, 149 person-trips were SMVs and 12 person-trips were Transparency Monitoring Office (TMO) trips. Additionally, there were 11 monitoring visits by TMO monitors to facilities other than UEIE and 3 to UEIE itself. There were two monitoring visits (source changes)more » that were back to back with 16 monitors. Each of these concurring visits were treated as single person-trips for dosimetry purposes. Counted individually, there were 191 individual person-visits in 2005. The LLNL Safety Laboratories Division provided the dosimetry services for the HEU-TP monitors.« less

  9. Everything is Data - Overview of Modular System of Sensors for Museum Environment

    NASA Astrophysics Data System (ADS)

    Valach, J.; Juliš, K.; Štefcová, P.; Pech, M.; Wolf, B.; Kotyk, M.; Frankl, J.

    2015-08-01

    The main aim of project nearing completion was to develop a modular and scalable system of sensors for monitoring of internal environment of museum exhibitions and depositories. The sensors vary according to parameters being monitored and at the same time also according to required energy autonomy, processing capability and bandwidth requirements. Sensors developed can be divided into three groups: environmental sensors, biosensors and sensors of vibrations. Data acquired by the sensors are archived and stored in open format. Metadata stored alongside true numerical data from measurement, represent assurance of future computer readability in data mining application. Long continuous series of data can provide sufficient data for acquisition of dose-response function.

  10. Influence of vehicles used for oral dosing of test molecules on the progression of Mycobacterium tuberculosis infection in mice.

    PubMed

    Singh, Shubhra; Dwivedi, Richa; Chaturvedi, Vinita

    2012-11-01

    Preclinical evaluation of drug-like molecules requires their oral administration to experimental animals using suitable vehicles. We studied the effect of oral dosing with corn oil, carboxymethyl cellulose, dimethyl sulfoxide, and polysorbate-80 on the progression of Mycobacterium tuberculosis infection in mice. Infection was monitored by physical (survival time and body weight) and bacteriological (viable counts in lungs) parameters. Compared with water, corn oil significantly improved both sets of parameters, whereas the other vehicles affected only physical parameters.

  11. Influence of Vehicles Used for Oral Dosing of Test Molecules on the Progression of Mycobacterium tuberculosis Infection in Mice

    PubMed Central

    Singh, Shubhra; Dwivedi, Richa

    2012-01-01

    Preclinical evaluation of drug-like molecules requires their oral administration to experimental animals using suitable vehicles. We studied the effect of oral dosing with corn oil, carboxymethyl cellulose, dimethyl sulfoxide, and polysorbate-80 on the progression of Mycobacterium tuberculosis infection in mice. Infection was monitored by physical (survival time and body weight) and bacteriological (viable counts in lungs) parameters. Compared with water, corn oil significantly improved both sets of parameters, whereas the other vehicles affected only physical parameters. PMID:22926571

  12. Evaluation of warfarin management with international normalized ratio self-testing and online remote monitoring and management plus low-dose vitamin k with genomic considerations: a pilot study.

    PubMed

    Bussey, Henry I; Bussey, Marie; Bussey-Smith, Kristin L; Frei, Christopher R

    2013-11-01

    As better international normalized ratio (INR) control and self-testing reduce events in warfarin-treated patients, and vitamin K supplementation may improve INR control, our primary objective was to evaluate the effect of a system combining frequent INR self-testing with online remote monitoring and management (STORM₂) and low-dose vitamin K supplementation on INR control; our secondary objectives were to assess the impact of STORM₂ on clinician time and to evaluate the influence of pharmacogenomics on INR stability and warfarin dose after vitamin K supplementation. Prospective pre- and postintervention study. Freestanding clinical research center. Fifty-five patients treated with long-term warfarin therapy who were referred from four anticoagulation clinics and seven medical practices. All patients performed weekly INR self-testing and received vitamin K 100 µg/day and online anticoagulation management for 1 year. INR control and time required for anticoagulation management were assessed, and an analysis of warfarin dosing and INR stability by genetic polymorphism subgroup (vitamin K epoxide reductase complex 1 [VKORC1] and cytochrome P450 2C9 isoenzyme) was performed; vitamin K product content was also analyzed. The percentage of time that the INR is within the time in therapeutic range (TTR) improved from 56% before the intervention to 81% after the intervention (p<0.0001), and time spent at extreme INR values of lower than 1.5 or higher than 5 was reduced from 3.1% to 0.4% (p=0.01). Clinician time was less than 10 minutes per four patient visits per month. Genetic polymorphisms did not correlate with INR stability or the increase in warfarin dose after vitamin K supplementation. The content of the vitamin K product, however, was only 34-76% of the labeled amount. Patients with the GG VKORC1 genotype required a higher warfarin dose than predicted by the genomic-based dosing chart in the warfarin package insert. The 25% point improvement in TTR with STORM₂ is a greater improvement than reported previously with other efforts to improve TTR. STORM₂ required a minimum amount of clinician time. Pharmacogenomics were not predictive of improved INR control or the magnitude of the warfarin dose after vitamin K supplementation, although the content of the product was unreliable. Patients with the GG VKORC1 genotype required a higher warfarin dose than predicted by the product information. The potential clinical impact of improved INR control with this method warrants comparisons with conventionally managed warfarin and with the new oral anticoagulants. © 2013 Pharmacotherapy Publications, Inc.

  13. TH-E-209-00: Radiation Dose Monitoring and Protocol Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  14. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B.

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  15. TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDougall, R.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  16. Mental Nerve Blocks for Lip Brachytherapy: A Case Report.

    PubMed

    Hafez, Osama; Ackerman, Robert S; Evans, Trip; Patel, Sephalie Y; Padalia, Devang M

    2018-05-15

    High dose rate interstitial brachytherapy is a commonly performed procedure for carcinoma of the lower lip. Placement of the brachytherapy catheters can be painful and may require monitored anesthesia care or general anesthesia. We present the use of bilateral mental nerve blocks with minimal sedation to facilitate placement of brachytherapy catheters.

  17. Eye lens dose in interventional cardiology.

    PubMed

    Principi, S; Delgado Soler, C; Ginjaume, M; Beltran Vilagrasa, M; Rovira Escutia, J J; Duch, M A

    2015-07-01

    The ICRP has recently recommended reducing the occupational exposure dose limit for the lens of the eye to 20 mSv y(-1), averaged over a period of 5 y, with no year exceeding 50 mSv, instead of the current 150 mSv y(-1). This reduction will have important implications for interventional cardiology and radiology (IC/IR) personnel. In this work, lens dose received by a staff working in IC is studied in order to determine whether eye lens dose monitoring or/and additional radiological protection measures are required. Eye lens dose exposure was monitored in 10 physicians and 6 nurses. The major IC procedures performed were coronary angiography and percutaneous transluminal coronary angioplasty. The personnel were provided with two thermoluminescent dosemeters (TLDs): one calibrated in terms of Hp(3) located close to the left ear of the operator and a whole-body dosemeter calibrated in terms of Hp(10) and Hp(0.07) positioned on the lead apron. The estimated annual eye lens dose for physicians ranged between 8 and 60 mSv, for a workload of 200 procedures y(-1). Lower doses were collected for nurses, with estimated annual Hp(3) between 2 and 4 mSv y(-1). It was observed that for nurses the Hp(0.07) measurement on the lead apron is a good estimate of eye lens dose. This is not the case for physicians, where the influence of both the position and use of protective devices such as the ceiling shield is very important and produces large differences among doses both at the eyes and on the thorax. For physicians, a good correlation between Hp(3) and dose area product is shown. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Power monitoring in space nuclear reactors using silicon carbide radiation detectors

    NASA Technical Reports Server (NTRS)

    Ruddy, Frank H.; Patel, Jagdish U.; Williams, John G.

    2005-01-01

    Space reactor power monitors based on silicon carbide (SiC) semiconductor neutron detectors are proposed. Detection of fast leakage neutrons using SiC detectors in ex-core locations could be used to determine reactor power: Neutron fluxes, gamma-ray dose rates and ambient temperatures have been calculated as a function of distance from the reactor core, and the feasibility of power monitoring with SiC detectors has been evaluated at several ex-core locations. Arrays of SiC diodes can be configured to provide the required count rates to monitor reactor power from startup to full power Due to their resistance to temperature and the effects of neutron and gamma-ray exposure, SiC detectors can be expected to provide power monitoring information for the fill mission of a space reactor.

  19. The Impact of AUC-Based Monitoring on Pharmacist-Directed Vancomycin Dose Adjustments in Complicated Methicillin-Resistant Staphylococcus aureus Infection.

    PubMed

    Stoessel, Andrew M; Hale, Cory M; Seabury, Robert W; Miller, Christopher D; Steele, Jeffrey M

    2018-01-01

    This study aimed to assess the impact of area under the curve (AUC)-based vancomycin monitoring on pharmacist-initiated dose adjustments after transitioning from a trough-only to an AUC-based monitoring method at our institution. A retrospective cohort study of patients treated with vancomycin for complicated methicillin-resistant Staphylococcus aureus (MRSA) infection between November 2013 and December 2016 was conducted. The frequency of pharmacist-initiated dose adjustments was assessed for patients monitored via trough-only and AUC-based approaches for trough ranges: 10 to 14.9 mg/L and 15 to 20 mg/L. Fifty patients were included: 36 in the trough-based monitoring and 14 in the AUC-based-monitoring group. The vancomycin dose was increased in 71.4% of patients when troughs were 10 to 14.9 mg/L when a trough-only approach was used and in only 25% of patients when using AUC estimation ( P = .048). In the AUC group, the dose was increased only when AUC/minimum inhibitory concentration (MIC) <400; unchanged regimens had an estimated AUC/MIC ≥400. The AUC-based monitoring did not significantly increase the frequency of dose reductions when trough concentrations were 15 to 20 mg/L (AUC: 33.3% vs trough: 4.6%; P = .107). The AUC-based monitoring resulted in fewer patients with dose adjustments when trough levels were 10 to 14.9 mg/L. The AUC-based monitoring has the potential to reduce unnecessary vancomycin exposure and warrants further investigation.

  20. Volumetric-modulated arc therapy in postprostatectomy radiotherapy patients: A planning comparison study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forde, Elizabeth, E-mail: eforde@tcd.ie; Kneebone, Andrew; Northern Clinical School, University of Sydney, New South Wales

    2013-10-01

    The purpose of this study was to compare postprostatectomy planning for volumetric-modulated arc therapy (VMAT) with both single arc (SA) and double arcs (DA) against dynamic sliding window intensity-modulated radiotherapy (IMRT). Ten cases were planned with IMRT, SA VMAT, and DA VMAT. All cases were planned to achieve a minimum dose of 68 Gy to 95% of the planning target volume (PTV) and goals to limit rectal volume >40 Gy to 35% and >65 Gy to 17%, and bladder volumes >40 Gy to 50% and >65 Gy to 25%. Plans were averaged across the 10 patients and compared for meanmore » dose, conformity, homogeneity, rectal and bladder doses, and monitor units. The mean dose to the clinical target volume and PTV was significantly higher (p<0.05) for SA compared with DA or IMRT. The homogeneity index was not significantly different: SA = 0.09; DA = 0.08; and IMRT = 0.07. The rectal V40 was lowest for the DA plan. The rectal V20 was significantly lower (p<0.05) for both the VMAT plans compared with IMRT. There were no significant differences for bladder V40 or rectal and bladder V65. The IMRT plans required 1400 MU compared with 745 for DA and 708 for SA. This study shows that for equivalent dose coverage, SA and DA VMAT plans result in higher mean doses to the clinical target volume and PTV. This greater dose heterogeneity is balanced by improved low-range rectal doses and halving of the monitor units.« less

  1. SU-E-T-504: Intensity-Modulated Radiosurgery Treatments Derived by Optimizing Delivery of Sphere Packing Treatment Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermansen, M; Bova, F; John, T St.

    2015-06-15

    Purpose To minimize the number of monitor units required to deliver a sphere packing stereotactic radiosurgery (SRS) plan by eliminating overlaps of individual beam projections. Methods An algorithm was written in C{sup ++} to calculate SRS treatment doses using sphere packing. Three fixed beams were used to approximate each arc in a typical SRS treatment plan. For cases involving multiple isocenters, at each gantry and table angle position beams directed to individual spheres overlap to produce regions of high dose, resulting in intensity modulated beams. These high dose regions were dampened by post-processing of the combined beam profile. The post-processmore » dampening involves removing the excess overlapping fluence from all but the highest contributing beam. The dampened beam profiles at each table and gantry angle position were then summed to produce the new total dose distribution. Results Delivery times for even the most complex multiple sphere plans can be reduced to consistent times of about 20 to 30 minutes. The total MUs required to deliver the plan can also be reduced by as much as 85% of the original plan’s MUs. Conclusion Regions of high dose are removed. Dampening overlapping radiation fluence can produce the new beam profiles that have more uniform dose distributions using less MUs. This results in a treatment that requires significantly fewer intensity values than traditional IMRT or VAMT planning.« less

  2. TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, D.

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilitiesmore » over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.« less

  3. Patient preferences and willingness to pay for different options of anticoagulant therapy.

    PubMed

    Moia, Marco; Mantovani, Lorenzo Giovanni; Carpenedo, Monica; Scalone, Luciana; Monzini, Mara Silvia; Cesana, Giancarlo; Mannucci, Pier Mannuccio

    2013-04-01

    New anticoagulant drugs alternative to vitamin K antagonists are currently under clinical evaluation. Patient's preferences should be considered in the development of new therapeutic strategies. Our study aim was to elicit patient preferences, and estimate their willingness to pay for the different treatment options. A Discrete Choice Experiment was administered to patients consecutively attending an anticoagulation clinic, either on stable oral anticoagulant therapy, or during their first visit at the time of starting therapy. Six treatment characteristics were analysed: route and number of medication administrations, frequency of monitoring, risk of some minor bleeding, the amount of attention required for drug/food interactions, requirement for dose adjustment, and out-of-pocket treatment cost. Relationships between patient's preferences and their characteristics were analysed. 255 patients participated (55 % men, with a mean age 64 years; 35.7 % on stable therapy). A statistically significant importance was attributed to all but two characteristics (the amount of attention required for interaction with other drugs/food and for dose adjustment.) Monthly patient willingness to pay was 79 for tablets versus injections; 41 for once-daily versus twice-daily tablets, 25 for drugs without risk of minor bleeding events and 20 for once-monthly versus twice-monthly monitoring. Patients on stable therapy considered more important the amount of attention required for drug/food interactions than did the starters. Younger or working patients considered the reduction of monitoring frequency more important than did the older or not working patients (retired, housewives). This study elicited preferences from patients on oral anticoagulant therapy with a simple and well established method, which allows to obtain information warranted for planning optimal healthcare.

  4. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring for surgical hip repair in two patients with severe aortic stenosis.

    PubMed

    López, María Mercedes; Guasch, Emilia; Schiraldi, Renato; Maggi, Genaro; Alonso, Eduardo; Gilsanz, Fernando

    2016-01-01

    Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area <1.0 cm(2) or a mean aortic valve gradient >30 mmHg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  5. Deliberate fingolimod overdose presenting with delayed hypotension and bradycardia responsive to atropine.

    PubMed

    Stephenson, M; Wong, A; Rotella, J A; Crump, N; Kerr, F; Greene, S L

    2014-06-01

    Fingolimod is an immunomodulating agent used in multiple sclerosis (MS). It is a sphingosine-1-phosphate (S1P) receptor agonist prescribed for relapsing forms of MS to delay onset of physical disability. As fingolimod is known to cause first-dose bradycardia, telemetry is recommended for the first 6 h post-dose. We present the first reported case of deliberate fingolimod overdose requiring atropine administration for bradycardia and hemodynamic instability. A 33-year-old woman ingested 14 mg of fingolimod and 2 g of phenoxymethylpenicillin. After presenting to the emergency department 19 h later, she was initially hemodynamically stable (heart rate (HR) 60, blood pressure (BP) 113/89 mmHg). Two hours later, she then developed bradycardia (HR 48) and hypotension (87/57 mmHg). Despite intravenous fluids, stabilisation was only achieved after administration of atropine (300 μg). She was then admitted to the intensive care unit (ICU) for further monitoring where another episode of bradycardia and hypotension required atropine. She was monitored in the ICU for 48 h and then discharged on day 5 with no further episodes. Fingolimod is known to cause bradycardia in the first 6 h post first therapeutic dose. Following intentional overdose, onset of bradycardia occurred at 21 h post-ingestion and was associated with hypotension. Atropine was successful in treating bradycardia and associated hypotension.

  6. A RANKL Wrinkle: Denosumab-Induced Hypocalcemia.

    PubMed

    Laskowski, Larissa K; Goldfarb, David S; Howland, Mary Ann; Kavcsak, Kelly; Lugassy, Danny M; Smith, Silas W

    2016-09-01

    The human monoclonal antibody denosumab inhibits osteoclast-mediated bone resorption by binding to receptor activator of nuclear factor κB ligand (RANKL), which is upregulated by tumor cells. Denosumab is indicated to prevent skeletal-related events (SREs) from osteoporosis and metastatic bone disease. We report a case of denosumab-induced hypocalcemia to highlight potential toxicity and treatment considerations. A 66-year-old man with prostate cancer, small cell lung cancer, and bone metastases presented with fatigue, weakness, and muscle spasm. Sixteen days prior, he received cycle 6 of cisplatin and etoposide, leuprolide, and denosumab (120 mg subcutaneously). His examination demonstrated a slight resting tremor, normal strength, and negative Chvostek sign. Laboratory analysis revealed hemoglobin, 8.0 g/dL; total calcium, 5.2 mg/dL (pre-denosumab, 8.9 mg/dL); and magnesium, 0.7 mg/dL. He initially received two units packed red blood cells, intravenous calcium and magnesium, and vitamin D. During his hospitalization, he required multiple doses of intravenous and oral calcium, magnesium, and vitamin D. Despite ongoing oral supplementation, his post-discharge serum calcium fluctuated significantly, requiring close monitoring and frequent dose adjustments. Denosumab's unique antiresorptive properties yield fewer SREs. The trade-off is increased hypocalcemia risk, which may be severe and require aggressive, prolonged supplementation and monitoring.

  7. A preliminary study into performing routine tube output and automatic exposure control quality assurance using radiology information system data.

    PubMed

    Charnock, P; Jones, R; Fazakerley, J; Wilde, R; Dunn, A F

    2011-09-01

    Data are currently being collected from hospital radiology information systems in the North West of the UK for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (QA) requirements according to UK guidance? From 2008 to 2009, 731 653 records were submitted from 8 hospitals from the North West England. For automatic exposure control QA, the protocol from Institute of Physics and Engineering in Medicine (IPEM) report 91 recommends that milliamperes per second can be monitored for repeatability and reproducibility using a suitable phantom, at 70-81 kV. Abdomen AP and chest PA examinations were analysed to find the most common kilovoltage used with these records then used to plot average monthly milliamperes per second with time. IPEM report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube, the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of AEC systems; however more work is required to be able to monitor tube output performance. Procedurally, the management system requires work and the benefits to the workflow would need to be demonstrated.

  8. The adequate rocuronium dose required for complete block of the adductor muscles of the thigh.

    PubMed

    Fujimoto, M; Kawano, K; Yamamoto, T

    2018-03-01

    Rocuronium can prevent the obturator jerk during transurethral resection of bladder tumors. We investigated the adequate rocuronium dose required for complete block of the thigh adductor muscles, and its correlation with individual responses of the adductor pollicis muscle to rocuronium. Eleven patients scheduled for transurethral resection of bladder tumors under general anesthesia were investigated. After general anesthesia induction, neuromuscular monitoring of the adductor pollicis muscle and ultrasonography-guided stimulation of the obturator nerve was commenced. Rocuronium, 0.15 mg/kg, was repeatedly administered intravenously. The adequate rocuronium dose required for complete block of the thigh muscles, defined as the cumulative dose of rocuronium administered until that time, and its correlation with the first twitch response of the adductor pollicis muscle on train-of-four stimulation after initial rocuronium administration was analyzed. The rocuronium dose found adequate for complete block of the thigh muscles was 0.30 mg/kg in seven patients and 0.45 mg/kg in the remaining four patients, which did not correlate with the first twitch response. At the time of complete block of the thigh muscles, the neuromuscular blockade level of the adductor pollicis muscle varied greatly, although the level was never more profound than a post-tetanic count of 1. Although the response of the adductor pollicis muscle to rocuronium cannot be used to determine the adequate rocuronium dose required for complete block of the thigh muscles, intense blockade, with maintenance of post-tetanic count at ≤ 1 in the adductor pollicis muscle is essential to prevent the obturator jerk. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Clean focus, dose and CD metrology for CD uniformity improvement

    NASA Astrophysics Data System (ADS)

    Lee, Honggoo; Han, Sangjun; Hong, Minhyung; Kim, Seungyoung; Lee, Jieun; Lee, DongYoung; Oh, Eungryong; Choi, Ahlin; Kim, Nakyoon; Robinson, John C.; Mengel, Markus; Pablo, Rovira; Yoo, Sungchul; Getin, Raphael; Choi, Dongsub; Jeon, Sanghuck

    2018-03-01

    Lithography process control solutions require more exacting capabilities as the semiconductor industry goes forward to the 1x nm node DRAM device manufacturing. In order to continue scaling down the device feature sizes, critical dimension (CD) uniformity requires continuous improvement to meet the required CD error budget. In this study we investigate using optical measurement technology to improve over CD-SEM methods in focus, dose, and CD. One of the key challenges is measuring scanner focus of device patterns. There are focus measurement methods based on specially designed marks on scribe-line, however, one issue of this approach is that it will report focus of scribe line which is potentially different from that of the real device pattern. In addition, scribe-line marks require additional design and troubleshooting steps that add complexity. In this study, we investigated focus measurement directly on the device pattern. Dose control is typically based on using the linear correlation behavior between dose and CD. The noise of CD measurement, based on CD-SEM for example, will not only impact the accuracy, but also will make it difficult to monitor dose signature on product wafers. In this study we will report the direct dose metrology result using an optical metrology system which especially enhances the DUV spectral coverage to improve the signal to noise ratio. CD-SEM is often used to measure CD after the lithography step. This measurement approach has the advantage of easy recipe setup as well as the flexibility to measure critical feature dimensions, however, we observe that CD-SEM metrology has limitations. In this study, we demonstrate within-field CD uniformity improvement through the extraction of clean scanner slit and scan CD behavior by using optical metrology.

  10. Failure of nasogastric omeprazole suspension in pediatric intensive care patients.

    PubMed

    Haizlip, Julie A; Lugo, Ralph A; Cash, Jared J; Vernon, Donald D

    2005-03-01

    To determine the efficacy of nasogastric administration of omeprazole suspension in raising the gastric pH >4 in critically ill pediatric patients and to determine the most appropriate dosing regimen for this indication. Open-label pharmacodynamic study. Twenty-six bed tertiary-care pediatric intensive care unit. Mechanically ventilated children aged 1-18 yrs with an additional risk factor for stress ulcer formation. Continuous gastric pH monitoring was performed during administration and dose titration of omeprazole suspension to achieve the goal of gastric pH >4 for greater than 75% of the dosing interval. Data were collected from 18 patients. Subjects were categorized based on the pharmacologic response to nasogastric administration of 1 mg/kg omeprazole suspension (maximum 20 mg) as rapid (n = 9), late (n = 5), and nonresponders (n = 4). Rapid responders required 0.72 mg/kg per day omeprazole suspension to achieve adequate gastric pH elevation for stress ulcer prophylaxis. Late responders required 1.58 mg/kg per day. Nonresponders did not achieve adequate elevation of gastric pH for stress ulcer prophylaxis. Nasogastric administration of omeprazole suspension has variable efficacy in critically ill pediatric patients. Half of the studied subjects either required significant dose titrations to achieve gastric acid suppression or did not respond to nasogastric administration of omeprazole suspension.

  11. An in-beam PET system for monitoring ion-beam therapy: test on phantoms using clinical 62 MeV protons

    NASA Astrophysics Data System (ADS)

    Camarlinghi, N.; Sportelli, G.; Battistoni, G.; Belcari, N.; Cecchetti, M.; Cirrone, G. A. P.; Cuttone, G.; Ferretti, S.; Kraan, A.; Retico, A.; Romano, F.; Sala, P.; Straub, K.; Tramontana, A.; Del Guerra, A.; Rosso, V.

    2014-04-01

    Ion therapy allows the delivery of highly conformal dose taking advantage of the sharp depth-dose distribution at the Bragg-peak. However, patient positioning errors and anatomical uncertainties can cause dose distortions. To exploit the full potential of ion therapy, an accurate monitoring system of the ion range is needed. Among the proposed methods to monitor the ion range, Positron Emission Tomography (PET) has proven to be the most mature technique, allowing to reconstruct the β+ activity generated in the patient by the nuclear interaction of the ions, that can be acquired during or after the treatment. Taking advantages of the spatial correlation between positron emitters created along the ions path and the dose distribution, it is possible to reconstruct the ion range. Due to the high single rates generated during the beam extraction, the acquisition of the β+ activity is typically performed after the irradiation (cyclotron) or in between the synchrotron spills. Indeed the single photon rate can be one or more orders of magnitude higher than normal for cyclotron. Therefore, acquiring the activity during the beam irradiation requires a detector with a very short dead time. In this work, the DoPET detector, capable of sustaining the high event rate generated during the cyclotron irradiation, is presented. The capability of the system to acquire data during and after the irradiation will be demonstrated by showing the reconstructed activity for different PMMA irradiations performed using clinical dose rates and the 62 MeV proton beam at the CATANA-LNS-INFN. The reconstructed activity widths will be compared with the results obtained by simulating the proton beam interaction with the FLUKA Monte Carlo. The presented data are in good agreement with the FLUKA Monte Carlo.

  12. Upgrades of DARWIN, a dose and spectrum monitoring system applicable to various types of radiation over wide energy ranges

    NASA Astrophysics Data System (ADS)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Shigyo, Nobuhiro; Watanabe, Fusao; Sakurai, Hiroki; Arai, Yoichi

    2011-05-01

    A dose and spectrum monitoring system applicable to neutrons, photons and muons over wide ranges of energy, designated as DARWIN, has been developed for radiological protection in high-energy accelerator facilities. DARWIN consists of a phoswitch-type scintillation detector, a data-acquisition (DAQ) module for digital waveform analysis, and a personal computer equipped with a graphical-user-interface (GUI) program for controlling the system. The system was recently upgraded by introducing an original DAQ module based on a field programmable gate array, FPGA, and also by adding a function for estimating neutron and photon spectra based on an unfolding technique without requiring any specific scientific background of the user. The performance of the upgraded DARWIN was examined in various radiation fields, including an operational field in J-PARC. The experiments revealed that the dose rates and spectra measured by the upgraded DARWIN are quite reasonable, even in radiation fields with peak structures in terms of both spectrum and time variation. These results clearly demonstrate the usefulness of DARWIN for improving radiation safety in high-energy accelerator facilities.

  13. Validating dose rate calibration of radiotherapy photon beams through IAEA/WHO postal audit dosimetry service.

    PubMed

    Jangda, Abdul Qadir; Hussein, Sherali

    2012-05-01

    In external beam radiation therapy (EBRT), the quality assurance (QA) of the radiation beam is crucial to the accurate delivery of the prescribed dose to the patient. One of the dosimetric parameters that require monitoring is the beam output, specified as the dose rate on the central axis under reference conditions. The aim of this project was to validate dose rate calibration of megavoltage photon beams using the International Atomic Energy Agency (IAEA)/World Health Organisation (WHO) postal audit dosimetry service. Three photon beams were audited: a 6 MV beam from the low-energy linac and 6 and 18 MV beams from a dual high-energy linac. The agreement between our stated doses and the IAEA results was within 1% for the two 6 MV beams and within 2% for the 18 MV beam. The IAEA/WHO postal audit dosimetry service provides an independent verification of dose rate calibration protocol by an international facility.

  14. Subclinical hyperthyroidism: possible danger of overzealous thyroxine replacement therapy.

    PubMed

    Ross, D S

    1988-12-01

    Many patients taking customary doses of levothyroxine have slightly elevated serum thyroxine (T4), apparently normal serum triiodothyronine, suppressed serum thyrotropin (thyroid-stimulating hormone; TSH) concentrations, and no clinical symptoms of hyperthyroidism. Recent reports suggest that these patients may have adverse effects from subclinical hyperthyroidism, including abnormally short systolic time intervals, elevations in liver enzymes, and reductions in bone density. Controversy exists about which thyroid function tests should be used to monitor patients taking levothyroxine. A review of currently available data suggests that replacement doses of levothyroxine given to hypothyroid patients should be adjusted so that serum TSH measured by the new sensitive assays is within the normal range. Patients requiring suppressive doses of levothyroxine to shrink goitrous thyroid tissue or to prevent growth of abnormal tissue should be given the minimal dose needed to accomplish the desired clinical or biochemical response.

  15. Monitoring and Modeling Astronaut Occupational Radiation Exposures in Space: Recent Advances

    NASA Technical Reports Server (NTRS)

    Weyland, Mark; Golightly, Michael

    1999-01-01

    In 1982 astronauts were declared to be radiation workers by OSHA, and as such were subject to the rules and regulations applied to that group. NASA was already aware that space radiation was a hazard to crewmembers and had been studying and monitoring astronaut doses since 1962 at the Johnson Space Center. It was quickly realized NASA would not be able to accomplish all of its goals if the astronauts were subject to the ground based radiation worker limits, and thus received a waiver from OSHA to establish independent limits. As part of the stipulation attached to setting new limits, OSHA included a requirement to perform preflight dose projections for each crew and inform them of the associated risks. Additional requirements included measuring doses from various sources during the flight, making every effort to prevent a crewmember from exceeding the new limits, and keeping all exposures As Low As Reasonably Achievable (a.k.a. ALARA - a common health physics principle). The assembly of the International Space Station (ISS) and its initial manned operations will coincide with the 4-5 year period of high space weather activity at the next maximum in the solar cycle. For the first time in NASA's manned program, US astronauts will be in orbit continuously throughout a solar maximum period. During this period, crews are at risk of significantly increased radiation exposures due to solar particle events and trapped electron belt enhancements following geomagnetic storms. The problem of protecting crews is compounded by the difficulty of providing continuous real-time monitoring over a period of a decade in an era of tightly constrained budgets. In order to prepare for ISS radiological support needs, the NASA Space Radiation Analysis Group and the NOAA Space Environment Center have undertaken a multiyear effort to improve and automate ground-based space weather monitoring systems and real-time radiation analysis tools. These improvements include a coupled, automated space weather monitoring and alarm system--SPE exposure analysis system, an advanced space weather data distribution and display system, and a high-fidelity space weather simulation system. In addition, significant new real-time space weather data sets, which will enhance the forecasting and now-casting of near-Earth space environment conditions, are being made available through unique NASA-NOAA-USAF collaborations. These new data sets include coronal mass ejection monitoring by the Solar and Heliospheric Observatory (SOHO) and in-situ plasma and particle monitoring at the L1 libration point by the Solar Wind Monitor (SWIM) and Advanced Composition Explorer (ACE) spacecraft. Advanced real-time radiation monitoring data from charged particle telescopes and tissue equivalent proportional counters will also be available to assist crew and flight controllers in monitoring the external and intravehicular radiation environment.

  16. Dose requirements of continuous infusion of rocuronium and atracurium throughout orthotopic liver transplantation in humans

    PubMed Central

    Weng, Xiao-chuan; Zhou, Liang; Fu, Yin-yan; Zhu, Sheng-mei; He, Hui-liang; Wu, Jian

    2005-01-01

    Objective: To compare the dose requirements of continuous infusion of rocuronium and atracurium throughout orthotopic liver transplantation (OLT) in humans. Methods: Twenty male patients undergoing liver transplantation were randomly assigned to two comparable groups of 10 patients each to receive a continuous infusion of rocuronium or atracurium under intravenous balanced anesthesia. The response of adductor pollicis to train-of-four (TOF) stimulation of unlar nerve was monitored. The infusion rates of rocuronium and atracurium were adjusted to maintain T1/Tc ratio of 2%~10%. The total dose of each drug given during each of the three phases of OLT was recorded. Results: Rocuronium requirement, which were (0.468±0.167) mg/(kg·h) during the paleohepatic phase, decreased significantly during the anhepatic phase to (0.303±0.134) mg/(kg·h) and returned to the initial values at the neohepatic period ((0.429±0.130) mg/(kg·h)); whereas atracuruim requirements remained unchanged during orthotopic liver transplantation. Conclusions: This study showed that the exclusion of the liver from the circulation results in the significantly reduced requirement of rocuronium while the requirement of atracurium was not changed, which suggests that the liver is of major importance in the clearance of rocuronium. A continuous infusion of atracurium with constant rate can provide stable neuromuscular blockade during the three stages of OLT. PMID:16130187

  17. Weight Loss and Variation of Levothyroxine Requirements in Hypothyroid Obese Patients After Bariatric Surgery.

    PubMed

    Fierabracci, Paola; Martinelli, Silvia; Tamberi, Anna; Piaggi, Paolo; Basolo, Alessio; Pelosini, Caterina; Ricco, Ilaria; Magno, Silvia; Querci, Giorgia; Ceccarini, Giovanni; Scartabelli, Giovanna; Salvetti, Guido; Vitti, Paolo; Santini, Ferruccio

    2016-04-01

    Obesity and hypothyroidism are both common disorders within the general population. Obese hypothyroid subjects require higher doses of levothyroxine (LT4) compared with normal weight individuals. Previous studies on the effects of bariatric surgery on LT4 dose requirements in hypothyroid subjects have provided conflicting results. The aim of this study was to evaluate the LT4 requirements in a group of obese subjects with acquired hypothyroidism, before and after weight loss achieved by bariatric surgery. Ninety-three obese hypothyroid subjects (mean age = 48 ± 9 years; mean body mass index = 45.9 ± 5.6 kg/m(2)), were evaluated before and 28 ± 8 months after bariatric surgery. Changes in the LT4 dose, anthropometric measures, and hormone values were evaluated. In 20 patients, data of body composition, assessed by dual energy X-ray absorptiometry, were also analyzed. On average, after weight loss, a significant reduction of the total dose of LT4 was documented (from 130.6 ± 48.5 to 116.2 ± 38.6 μg/day; p < 0.001). The LT4 dose had to be reduced in 47 patients, was unchanged in 34, and had to be increased in 12 patients affected by autoimmune thyroiditis. Reduction of the LT4 dose was proportional to reduction of the lean body mass. The weight loss achieved with modern surgical bariatric procedures is associated with a reduction of LT4 requirements in most hypothyroid subjects, which appears to be related to a decrease of the lean body mass. Occasionally, a concurrent decline of residual thyroid function, as it occurs in autoimmune thyroiditis, can counteract this phenomenon and eventually produce an increase of LT4 needs. It is believed that during the weight loss phase that follows bariatric surgery, there is no need for preventive adjustments of the LT4 dose, but serum thyroid hormones and thyrotropin should be periodically monitored in order to detect possible variations of LT4 requirements and to allow proper corrections of the therapy.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goke, Sarah Hayes; Elliott, Nathan Ryan

    The Sandia National Laboratories’ Internal Dosimetry Technical Basis Manual is intended to provide extended technical discussion and justification of the internal dosimetry program at SNL. It serves to record the approach to evaluating internal doses from radiobioassay data, and where appropriate, from workplace monitoring data per the Department of Energy Internal Dosimetry Program Guide DOE G 441.1C. The discussion contained herein is directed primarily to current and future SNL internal dosimetrists. In an effort to conserve space in the TBM and avoid duplication, it contains numerous references providing an entry point into the internal dosimetry literature relevant to this program.more » The TBM is not intended to act as a policy or procedure statement, but will supplement the information normally found in procedures or policy documents. The internal dosimetry program outlined in this manual is intended to meet the requirements of Federal Rule 10CFR835 for monitoring the workplace and for assessing internal radiation doses to workers.« less

  19. NOTE: Cell-phone interference with pocket dosimeters

    NASA Astrophysics Data System (ADS)

    Djajaputra, David; Nehru, Ramasamy; Bruch, Philip M.; Ayyangar, Komanduri M.; Raman, Natarajan V.; Enke, Charles A.

    2005-05-01

    Accurate reporting of personal dose is required by regulation for hospital personnel that work with radioactive material. Pocket dosimeters are commonly used for monitoring this personal dose. We show that operating a cell phone in the vicinity of a pocket dosimeter can introduce large and erroneous readings of the dosimeter. This note reports a systematic study of this electromagnetic interference. We found that simple practical measures are enough to mitigate this problem, such as increasing the distance between the cell phone and the dosimeter or shielding the dosimeter, while maintaining its sensitivity to ionizing radiation, by placing it inside a common anti-static bag.

  20. Radiological assessment for bauxite mining and alumina refining.

    PubMed

    O'Connor, Brian H; Donoghue, A Michael; Manning, Timothy J H; Chesson, Barry J

    2013-01-01

    Two international benchmarks assess whether the mining and processing of ores containing Naturally Occurring Radioactive Material (NORM) require management under radiological regulations set by local jurisdictions. First, the 1 Bq/g benchmark for radionuclide head of chain activity concentration determines whether materials may be excluded from radiological regulation. Second, processes may be exempted from radiological regulation where occupational above-background exposures for members of the workforce do not exceed 1 mSv/year. This is also the upper-limit of exposure prescribed for members of the public. Alcoa of Australia Limited (Alcoa) has undertaken radiological evaluations of the mining and processing of bauxite from the Darling Range of Western Australia since the 1980s. Short-term monitoring projects have demonstrated that above-background exposures for workers do not exceed 1 mSv/year. A whole-of-year evaluation of above-background, occupational radiological doses for bauxite mining, alumina refining and residue operations was conducted during 2008/2009 as part of the Alcoa NORM Quality Assurance System (NQAS). The NQAS has been guided by publications from the International Commission on Radiological Protection (ICRP), the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). The NQAS has been developed specifically in response to implementation of the Australian National Directory on Radiation Protection (NDRP). Positional monitoring was undertaken to increase the accuracy of natural background levels required for correction of occupational exposures. This is important in view of the small increments in exposure that occur in bauxite mining, alumina refining and residue operations relative to natural background. Positional monitoring was also undertaken to assess the potential for exposure in operating locations. Personal monitoring was undertaken to characterise exposures in Similar Exposure Groups (SEGs). The monitoring was undertaken over 12 months, to provide annual average assessments of above-background doses, thereby reducing temporal variations, especially for radon exposures. The monitoring program concentrated on gamma and radon exposures, rather than gross alpha exposures, as past studies have shown that gross alpha exposures from inhalable dust for most of the workforce are small in comparison to combined gamma and radon exposures. The natural background determinations were consistent with data in the literature for localities near Alcoa's mining, refining and residue operations in Western Australia, and also with UNSCEAR global data. Within the mining operations, there was further consistency between the above-background dose estimates and the local geochemistry, with slight elevation of dose levels in mining pits. Conservative estimates of above-background levels for the workforce have been made using an assumption of 100% occupancy (1920 hours per year) for the SEGs considered. Total incremental composite doses for individuals were clearly less than 1.0 mSv/year when gamma, radon progeny and gross alpha exposures were considered. This is despite the activity concentration of some materials being slightly higher than the benchmark of 1 Bq/g. The results are consistent with previous monitoring and demonstrate compliance with the 1 mSv/year exemption level within mining, refining and residue operations. These results will be of value to bauxite mines and alumina refineries elsewhere in the world.

  1. Milrinone in advanced heart failure: dose and therapeutic monitor outside intensive care unit.

    PubMed

    Charisopoulou, Dafni; Leaver, Neil; Banner, Nicholas R

    2014-04-01

    Advanced chronic heart failure (ACHF) patients often require inotropes before transplantation or ventricular assist device implantation. Milrinone, an inotrope and vasodilator, may accumulate in cardiorenal syndrome with serious adverse effects. We investigated the potential for therapeutic drug monitoring of milrinone levels using High Performance Liquid Chromatography Mass Spectrometry (HPLC-MS). 22 ACHF patients (15 males, 49±9 years) received milrinone 50 µg/kg intravenously (i.v.) during heart catheterization. Milrinone levels were 216±71 ng/ml (within the reported therapeutic range: 100-300 ng/ml), followed by improvements in cardiac index, pulmonary artery and wedge pressures (p < 0.005). 18 ACHF patients (17 males, 50±12 years, 13 had renal dysfunction) received continuous i.v. milrinone (5-26 days) at 0.1-0.2 µg/kg/min, titrated according to plasma milrinone levels. No adverse events occurred. Therapeutic levels were achieved with doses of 0.2±0.06 µg/Kg/min, below those recommended in Summary of Product Characteristics. Milrinone therapy can be noninvasively monitored by HPLC-MS, while avoiding toxicity in ACHF.

  2. Digoxin therapeutic drug monitoring practices. A College of American Pathologists Q-Probes study of 666 institutions and 18,679 toxic levels.

    PubMed

    Howanitz, P J; Steindel, S J

    1993-07-01

    We investigated digoxin therapeutic drug monitoring practices in 666 institutions participating in Q-Probes, a quality improvement program of the College of American Pathologists. Participants used 13 different lower and 16 different upper limits for their therapeutic range. More than 280,000 digoxin levels were studied, and 6.7% (n = 8679) of results were in the toxic range (> 2.6 nmol/L). For the 77% of patients with toxic levels, the last digoxin dose was given orally; for 23% of patients, it was given intravenously; and for less than 1%, it was given intramuscularly. Between 22% and 31% of specimens in the toxic range were obtained before steady state had occurred, depending on the criteria used. Small institutions (less than 150 beds), outpatients, stat specimens, and laboratory policies not requiring the time of the last dose before measurement were associated with higher percentages of specimens drawn before the recommended time had elapsed. We describe digoxin monitoring practice patterns and provide suggestions for improvement.

  3. A new apparatus for on-site calibration of gamma dose rate monitors

    NASA Astrophysics Data System (ADS)

    Zhang, Yu; Chen, Bo; Zhao, Chao; Zhuo, Weihai

    2018-01-01

    In order to carry out on-site calibrations of environmental gamma dose rate monitors, a new irradiation apparatus was developed in this study. The apparatus mainly consists of a piece of 137Cs source, a set of beam attenuators, and 3 built-in laser rangefinders, and it can be remotely controlled by using a laptop through WiFi network. With an activity of 4.6 × 108 Bq of 137Cs source, the reference air kerma rate could be adjusted from 0.26 μGy h-1 to 140 μGy h-1 by changing the calibration distance from 0.5 m to 5 m and using different beam attenuators (or none), and both the reproducibility and the homogeneity of reference radiation were better than 97%. The overall uncertainty of the calibration was estimated to be 6.5% (k = 2). Both the laboratory and field experiments confirmed that the calibration method met the requirements of ISO 4037-1. As the advantages of portability and simplicity, it is considered that the new irradiation apparatus is applicable to stationary gamma radiation monitors for on-site calibration.

  4. Therapeutic drug monitoring in pregnancy.

    PubMed

    Matsui, Doreen M

    2012-10-01

    Therapeutic drug monitoring (TDM) is commonly recommended to optimize drug dosing regimens of various medications. It has been proposed to guide therapy in pregnant women, in whom physiological changes may lead to altered pharmacokinetics resulting in difficulty in predicting the appropriate drug dosage. Ideally, TDM may play a role in enhancing the effectiveness of treatment while minimizing toxicity of both the mother and fetus. Monitoring of drug levels may also be helpful in assessing adherence to prescribed therapy in selected cases. Limitations exist as therapeutic ranges have only been defined for a limited number of drugs and are based on data obtained in nonpregnant patients. TDM has been suggested for anticonvulsants, antidepressants, and antiretroviral drugs, based on pharmacokinetic studies that have shown reduced drug concentrations. However, there is only relatively limited (and sometimes inconsistent) information regarding the clinical impact of these pharmacokinetic changes during pregnancy and the effect of subsequent dose adjustments. Further studies are required to determine whether implementation of TDM during pregnancy improves outcome and is associated with any benefit beyond that achieved by clinical judgment alone. The cost effectiveness of TDM programs during pregnancy also remains to be examined.

  5. Oak Ridge Reservation Environmental Protection Rad Neshaps Radionuclide Inventory Web Database and Rad Neshaps Source and Dose Database

    DOE PAGES

    Scofield, Patricia A.; Smith, Linda Lenell; Johnson, David N.

    2017-07-01

    The U.S. Environmental Protection Agency promulgated national emission standards for emissions of radionuclides other than radon from US Department of Energy facilities in Chapter 40 of the Code of Federal Regulations (CFR) 61, Subpart H. This regulatory standard limits the annual effective dose that any member of the public can receive from Department of Energy facilities to 0.1 mSv. As defined in the preamble of the final rule, all of the facilities on the Oak Ridge Reservation, i.e., the Y–12 National Security Complex, Oak Ridge National Laboratory, East Tennessee Technology Park, and any other U.S. Department of Energy operations onmore » Oak Ridge Reservation, combined, must meet the annual dose limit of 0.1 mSv. At Oak Ridge National Laboratory, there are monitored sources and numerous unmonitored sources. To maintain radiological source and inventory information for these unmonitored sources, e.g., laboratory hoods, equipment exhausts, and room exhausts not currently venting to monitored stacks on the Oak Ridge National Laboratory campus, the Environmental Protection Rad NESHAPs Inventory Web Database was developed. This database is updated annually and is used to compile emissions data for the annual Radionuclide National Emission Standards for Hazardous Air Pollutants (Rad NESHAPs) report required by 40 CFR 61.94. It also provides supporting documentation for facility compliance audits. In addition, a Rad NESHAPs source and dose database was developed to import the source and dose summary data from Clean Air Act Assessment Package—1988 computer model files. As a result, this database provides Oak Ridge Reservation and facility-specific source inventory; doses associated with each source and facility; and total doses for the Oak Ridge Reservation dose.« less

  6. Recommendations for the use of methotrexate in rheumatoid arthritis: up and down scaling of the dose and administration routes.

    PubMed

    Tornero Molina, Jesús; Ballina García, Francisco Javier; Calvo Alén, Jaime; Caracuel Ruiz, Miguel Ángel; Carbonell Abelló, Jordi; López Meseguer, Antonio; Moreno Muelas, José Vicente; Pérez Sandoval, Trinidad; Quijada Carrera, Jesús; Trenor Larraz, Pilar; Zea Mendoza, Antonio

    2015-01-01

    To describe the optimal therapeutic strategy for use of methotrexate in RA patients over the initial dose, route of administration, dose increase and decrease, patient monitoring, and use of folic/folinic acid. Eleven clinical experts proposed some questions to be solved. A systematic literature search was conducted. The contents were selected in a work session and subsequently validated via email to establish the level of agreement. The initial dose of methotrexate should not be <10mg/week, preferably orally, but considering the parenteral route as an alternative due to compliance, non effectiveness of treatment or gastrointestinal side effects, polypharmacy, obesity (if required doses are >20mg/week), patient preference, very active disease or to avoid administration errors. Changing to a parenteral administration is proposed when the oral route is not effective enough, gastrointestinal toxicity appears, there is non-compliance or due to cost-effectiveness reasons before using more expensive drugs. On the contrary, due to patient preferences, intolerance to injections, dose reduction <7.5mg/week, non effectiveness of the route, poor compliance or gastrointestinal side effects. There should be a rapid dose escalation if inadequate responses occurr up to 15-20 or even 25mg/week in about 8 weeks, with increments of 2.5-5mg. The reduction will be carried out according to the dose the patient had, with decreases of 2.5-5mg every 3-6 months. Patient monitoring should be performed every 1-1.5 months until stability and then every 1-3 months. This document pretends to solve some common clinical questions and facilitate decision-making in RA patients treated with methotrexate. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  7. Oak Ridge Reservation Environmental Protection Rad Neshaps Radionuclide Inventory Web Database and Rad Neshaps Source and Dose Database.

    PubMed

    Scofield, Patricia A; Smith, Linda L; Johnson, David N

    2017-07-01

    The U.S. Environmental Protection Agency promulgated national emission standards for emissions of radionuclides other than radon from US Department of Energy facilities in Chapter 40 of the Code of Federal Regulations (CFR) 61, Subpart H. This regulatory standard limits the annual effective dose that any member of the public can receive from Department of Energy facilities to 0.1 mSv. As defined in the preamble of the final rule, all of the facilities on the Oak Ridge Reservation, i.e., the Y-12 National Security Complex, Oak Ridge National Laboratory, East Tennessee Technology Park, and any other U.S. Department of Energy operations on Oak Ridge Reservation, combined, must meet the annual dose limit of 0.1 mSv. At Oak Ridge National Laboratory, there are monitored sources and numerous unmonitored sources. To maintain radiological source and inventory information for these unmonitored sources, e.g., laboratory hoods, equipment exhausts, and room exhausts not currently venting to monitored stacks on the Oak Ridge National Laboratory campus, the Environmental Protection Rad NESHAPs Inventory Web Database was developed. This database is updated annually and is used to compile emissions data for the annual Radionuclide National Emission Standards for Hazardous Air Pollutants (Rad NESHAPs) report required by 40 CFR 61.94. It also provides supporting documentation for facility compliance audits. In addition, a Rad NESHAPs source and dose database was developed to import the source and dose summary data from Clean Air Act Assessment Package-1988 computer model files. This database provides Oak Ridge Reservation and facility-specific source inventory; doses associated with each source and facility; and total doses for the Oak Ridge Reservation dose.

  8. Oak Ridge Reservation Environmental Protection Rad Neshaps Radionuclide Inventory Web Database and Rad Neshaps Source and Dose Database

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scofield, Patricia A.; Smith, Linda Lenell; Johnson, David N.

    The U.S. Environmental Protection Agency promulgated national emission standards for emissions of radionuclides other than radon from US Department of Energy facilities in Chapter 40 of the Code of Federal Regulations (CFR) 61, Subpart H. This regulatory standard limits the annual effective dose that any member of the public can receive from Department of Energy facilities to 0.1 mSv. As defined in the preamble of the final rule, all of the facilities on the Oak Ridge Reservation, i.e., the Y–12 National Security Complex, Oak Ridge National Laboratory, East Tennessee Technology Park, and any other U.S. Department of Energy operations onmore » Oak Ridge Reservation, combined, must meet the annual dose limit of 0.1 mSv. At Oak Ridge National Laboratory, there are monitored sources and numerous unmonitored sources. To maintain radiological source and inventory information for these unmonitored sources, e.g., laboratory hoods, equipment exhausts, and room exhausts not currently venting to monitored stacks on the Oak Ridge National Laboratory campus, the Environmental Protection Rad NESHAPs Inventory Web Database was developed. This database is updated annually and is used to compile emissions data for the annual Radionuclide National Emission Standards for Hazardous Air Pollutants (Rad NESHAPs) report required by 40 CFR 61.94. It also provides supporting documentation for facility compliance audits. In addition, a Rad NESHAPs source and dose database was developed to import the source and dose summary data from Clean Air Act Assessment Package—1988 computer model files. As a result, this database provides Oak Ridge Reservation and facility-specific source inventory; doses associated with each source and facility; and total doses for the Oak Ridge Reservation dose.« less

  9. Establishment of the central radiation dose registration system for decontamination work involving radioactive fallout emitted by the Fukushima Daiichi APP accident.

    PubMed

    Yasui, Shojiro

    2016-10-01

    With respect to radiation protection for decontamination efforts involving radioactive fallout emitted by the accident at the Fukushima Daiichi Atomic Power Plant, new regulations were established and obligated employers to monitor, record, and store of workers' dose records, and to check their past dose records at the time of employment. However, cumulative doses may not be properly maintained if a worker declares incorrect values for past doses. In response, with facilitation from the Ministry of Health, Labour and Welfare, primary contractors of decontamination works decided to establish a central dose registration system. There are four major issues in the design of the system to be resolved, included the following: primary contractors (a) do not have a legal responsibility to perform dose control for subcontractors, (b) do not have the right to control decontamination sites, (c) often organize joint ventures, and (d) correspond to a wide range of ambient dose rates. To resolve the issues, requirements of the system included the following: (a) centralize the operation of radiation passbooks, which records past doses and the results of medical examinations to each worker; (b) develop a database system that could register all dose data and accept inquiry from primary contractors; (c) establish a permanent data storage system for transferred records; and (d) provide graded type of services that are appropriate to the risk of radiation exposure. The system started its operation in December 2013 and provided dose distributions in April and July 2015. The average yearly dose in 2014 was 0.7 mSv, which increased by 0.2 mSv from 0.5 mSv in 2012 and 2013. However, no cumulative dose from 2012-2014 exceeded 20 mSv, which was far below than the dose limits (100 mSv/5 years and 50 mSv/year). Although current dose distributions of decontamination workers were within appropriate levels, careful monitoring of dose distribution is necessary for preserving the proper implementation of radiation protection prescribed in the regulations.

  10. Measurements of secondary neutrons from cosmic radiation with a Bonner sphere spectrometer at 79 degrees N.

    PubMed

    Rühm, Werner; Mares, V; Pioch, C; Weitzenegger, E; Vockenroth, R; Paretzke, H G

    2009-04-01

    Air crew members and airline passengers are continuously exposed to cosmic radiation during their flights. Particles ejected by the sun during so-called solar particle events (SPEs) in periods of high solar activity can contribute to this exposure. In rare cases the dose from a single SPE might even exceed the annual dose limit of 1 mSv above which dose monitoring of air crews is legally required in Germany. Measurements performed by means of neutron monitors have already shown that the relative intensity of secondary neutrons from cosmic radiation is enhanced during an SPE, particularly at regions close to the magnetic poles of the Earth where shielding of the cosmic radiation by the geomagnetic field is low. Here we describe a Bonner sphere spectrometer installed at the Koldewey station at 79 degrees N, i.e. about 1,000 km from the geographic North pole, which is designed to provide first experimental data on the time-dependent energy spectrum of neutrons produced in the atmosphere during an SPE. This will be important to calculate doses from these neutrons to air crew members. The system is described in detail and first results are shown that were obtained during quiet periods of sun activity.

  11. Population Pharmacokinetics of Enoxaparin in Pediatric Patients.

    PubMed

    Moffett, Brady S; Lee-Kim, YoungNa; Galati, Marianne; Mahoney, Donald; Shah, Mona D; Teruya, Jun; Yee, Donald

    2018-02-01

    There are no studies evaluating the pharmacokinetics of enoxaparin in the hospitalized pediatric patient population. To characterize the pharmacokinetics of enoxaparin in pediatric patients. A retrospective review of inpatients 1 to 18 years of age admitted to our institution who received enoxaparin with anti-factor Xa activity level monitoring was performed. Demographic variables, enoxaparin dosing, and anti-factor Xa activity levels were collected. Population pharmacokinetic analysis was performed with bootstrap analysis. Simulation (n = 10 000) was performed to determine the percentage who achieved targeted anti-Xa levels at various doses. A total of 853 patients (male 52.1%, median age = 12.2 years; interquartile range [IQR] = 4.6-15.8 years) received a mean enoxaparin dose of 0.86 ± 0.31 mg/kg/dose. A median of 3 (IQR = 1-5) anti-factor Xa levels were sampled at 4.4 ± 1.3 hours after a dose, with a mean anti-factor Xa level of 0.52 ± 0.23 U/mL. A 1-compartment model best fit the data, and significant covariates included allometrically scaled weight, serum creatinine, and hematocrit on clearance, and platelets on volume of distribution. Simulations were run for patients both without and with reduced kidney function (creatinine clearance of ≤30 mL/min/1.73 m 2 ). A dose of 1 mg/kg/dose every 12 hours had the highest probability (72.3%) of achieving an anti-Xa level within the target range (0.5-1 U/mL), whereas a dose reduction of ~30% achieved the same result in patients with reduced kidney function. Pediatric patients should initially be dosed at 1-mg/kg/dose subcutaneously every 12 hours for treatment of thromboembolism followed by anti-Xa activity monitoring. Dose reductions of ~30% for creatinine clearance ≤30 mL/min/1.73 m 2 are required.

  12. Spot Weight Adaptation for Moving Target in Spot Scanning Proton Therapy.

    PubMed

    Morel, Paul; Wu, Xiaodong; Blin, Guillaume; Vialette, Stéphane; Flynn, Ryan; Hyer, Daniel; Wang, Dongxu

    2015-01-01

    This study describes a real-time spot weight adaptation method in spot-scanning proton therapy for moving target or moving patient, so that the resultant dose distribution closely matches the planned dose distribution. The method proposed in this study adapts the weight (MU) of the delivering pencil beam to that of the target spot; it will actually hit during patient/target motion. The target spot that a certain delivering pencil beam may hit relies on patient monitoring and/or motion modeling using four-dimensional (4D) CT. After the adapted delivery, the required total weight [Monitor Unit (MU)] for this target spot is then subtracted from the planned value. With continuous patient motion and continuous spot scanning, the planned doses to all target spots will eventually be all fulfilled. In a proof-of-principle test, a lung case was presented with realistic temporal and motion parameters; the resultant dose distribution using spot weight adaptation was compared to that without using this method. The impact of the real-time patient/target position tracking or prediction was also investigated. For moderate motion (i.e., mean amplitude 0.5 cm), D95% to the planning target volume (PTV) was only 81.5% of the prescription (RX) dose; with spot weight adaptation PTV D95% achieves 97.7% RX. For large motion amplitude (i.e., 1.5 cm), without spot weight adaptation PTV D95% is only 42.9% of RX; with spot weight adaptation, PTV D95% achieves 97.7% RX. Larger errors in patient/target position tracking or prediction led to worse final target coverage; an error of 3 mm or smaller in patient/target position tracking is preferred. The proposed spot weight adaptation method was able to deliver the planned dose distribution and maintain target coverage when patient motion was involved. The successful implementation of this method would rely on accurate monitoring or prediction of patient/target motion.

  13. Pharmacokinetics of voriconazole after oral administration of single and multiple doses in Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Sanchez-Migallon Guzman, David; Flammer, Keven; Papich, Mark G; Grooters, Amy M; Shaw, Shannon; Applegate, Jeff; Tully, Thomas N

    2010-04-01

    To determine the pharmacokinetics and safety of voriconazole administered orally in single and multiple doses in Hispaniolan Amazon parrots (Amazona ventralis). 15 clinically normal adult Hispaniolan Amazon parrots. Single doses of voriconazole (12 or 24 mg/kg) were administered orally to 15 and 12 birds, respectively; plasma voriconazole concentrations were determined at intervals via high-pressure liquid chromatography. In a multiple-dose trial, voriconazole (18 mg/kg) or water was administered orally to 6 and 4 birds, respectively, every 8 hours for 11 days (beginning day 0); trough plasma voriconazole concentrations were evaluated on 3 days. Birds were monitored daily, and clinicopathologic variables were evaluated before and after the trial. Voriconazole elimination half-life was short (0.70 to 1.25 hours). In the single-dose experiments, higher drug doses yielded proportional increases in the maximum plasma voriconazole concentration (C(max)) and area under the curve (AUC). In the multiple-dose trial, C(max), AUC, and plasma concentrations at 2 and 4 hours were decreased on day 10, compared with day 0 values; however, there was relatively little change in terminal half-life. With the exception of 1 voriconazole-treated parrot that developed polyuria, adverse effects were not evident. In Hispaniolan Amazon parrots, oral administration of voriconazole was associated with proportional kinetics following administration of single doses and a decrease in plasma concentration following administration of multiple doses. Oral administration of 18 mg of voriconazole/kg every 8 hours would require adjustment to maintain therapeutic concentrations during long-term treatment. Safety and efficacy of voriconazole treatment in this species require further investigation.

  14. MO-FG-202-08: Real-Time Monte Carlo-Based Treatment Dose Reconstruction and Monitoring for Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Z; Shi, F; Gu, X

    2016-06-15

    Purpose: This proof-of-concept study is to develop a real-time Monte Carlo (MC) based treatment-dose reconstruction and monitoring system for radiotherapy, especially for the treatments with complicated delivery, to catch treatment delivery errors at the earliest possible opportunity and interrupt the treatment only when an unacceptable dosimetric deviation from our expectation occurs. Methods: First an offline scheme is launched to pre-calculate the expected dose from the treatment plan, used as ground truth for real-time monitoring later. Then an online scheme with three concurrent threads is launched while treatment delivering, to reconstruct and monitor the patient dose in a temporally resolved fashionmore » in real-time. Thread T1 acquires machine status every 20 ms to calculate and accumulate fluence map (FM). Once our accumulation threshold is reached, T1 transfers the FM to T2 for dose reconstruction ad starts to accumulate a new FM. A GPU-based MC dose calculation is performed on T2 when MC dose engine is ready and a new FM is available. The reconstructed instantaneous dose is directed to T3 for dose accumulation and real-time visualization. Multiple dose metrics (e.g. maximum and mean dose for targets and organs) are calculated from the current accumulated dose and compared with the pre-calculated expected values. Once the discrepancies go beyond our tolerance, an error message will be send to interrupt the treatment delivery. Results: A VMAT Head-and-neck patient case was used to test the performance of our system. Real-time machine status acquisition was simulated here. The differences between the actual dose metrics and the expected ones were 0.06%–0.36%, indicating an accurate delivery. ∼10Hz frequency of dose reconstruction and monitoring was achieved, with 287.94s online computation time compared to 287.84s treatment delivery time. Conclusion: Our study has demonstrated the feasibility of computing a dose distribution in a temporally resolved fashion in real-time and quantitatively and dosimetrically monitoring the treatment delivery.« less

  15. A pilot study: dose adaptation of capecitabine using mobile phone toxicity monitoring - supporting patients in their homes.

    PubMed

    Weaver, Andrew; Love, Sharon B; Larsen, Mark; Shanyinde, Milensu; Waters, Rachel; Grainger, Lisa; Shearwood, Vanessa; Brooks, Claire; Gibson, Oliver; Young, Annie M; Tarassenko, Lionel

    2014-10-01

    Real-time symptom monitoring using a mobile phone is potentially advantageous for patients receiving oral chemotherapy. We therefore conducted a pilot study of patient dose adaptation using mobile phone monitoring of specific symptoms to investigate relative dose intensity of capecitabine, level of toxicity and perceived supportive care. Patients with breast or colorectal cancer receiving capecitabine completed a symptom, temperature and dose diary twice a day using a mobile phone application. This information was encrypted and automatically transmitted in real time to a secure server, with moderate levels of toxicity automatically prompting self-care symptom management messages on the screen of the patient's mobile phone or in severe cases, a call from a specialist nurse to advise on care according to an agreed protocol. Patients (n = 26) completed the mobile phone diary on 92.6 % of occasions. Twelve patients had a maximum toxicity grade of 3 (46.2 %). The average dose intensity for all patients as a percentage of standard dose was 90 %. In eight patients, the dose of capecitabine was reduced, and in eight patients, the dose of capecitabine was increased. Patients and healthcare professionals involved felt reassured by the novel monitoring system, in particular, during out of hours. It is possible to optimise the individual dose of oral chemotherapy safely including dose increase and to manage chemotherapy side effects effectively using real-time mobile phone monitoring of toxicity parameters entered by the patient.

  16. Graduated Exposure and Compliance Training Intervention for Blood Draw Avoidance and Refusal in a Woman with Intellectual Disability and Schizoaffective Disorder

    ERIC Educational Resources Information Center

    Cromartie, R. Samuel; Flood, William A.; Luiselli, James K.

    2014-01-01

    This case report concerns a woman with intellectual disability, schizoaffective disorder, and avoidance and refusal of having her blood drawn. She required but refused blood draws to properly monitor the therapeutic dose of a necessary psychotropic medication. During intervention at a community-based habilitation setting and under simulated…

  17. Design and qualification of the SEU/TD Radiation Monitor chip

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G.; Blaes, Brent R.; Soli, George A.; Zamani, Nasser; Hicks, Kenneth A.

    1992-01-01

    This report describes the design, fabrication, and testing of the Single-Event Upset/Total Dose (SEU/TD) Radiation Monitor chip. The Radiation Monitor is scheduled to fly on the Mid-Course Space Experiment Satellite (MSX). The Radiation Monitor chip consists of a custom-designed 4-bit SRAM for heavy ion detection and three MOSFET's for monitoring total dose. In addition the Radiation Monitor chip was tested along with three diagnostic chips: the processor monitor and the reliability and fault chips. These chips revealed the quality of the CMOS fabrication process. The SEU/TD Radiation Monitor chip had an initial functional yield of 94.6 percent. Forty-three (43) SEU SRAM's and 14 Total Dose MOSFET's passed the hermeticity and final electrical tests and were delivered to LL.

  18. Active Radiation Detectors for Use in Space Beyond Low Earth Orbit: Spatial and Energy Resolution Requirements and Methods for Heavy Ion Charge Classification

    NASA Astrophysics Data System (ADS)

    McBeth, Rafe A.

    Space radiation exposure to astronauts will need to be carefully monitored on future missions beyond low earth orbit. NASA has proposed an updated radiation risk framework that takes into account a significant amount of radiobiological and heavy ion track structure information. These models require active radiation detection systems to measure the energy and ion charge Z. However, current radiation detection systems cannot meet these demands. The aim of this study was to investigate several topics that will help next generation detection systems meet the NASA objectives. Specifically, this work investigates the required spatial resolution to avoid coincident events in a detector, the effects of energy straggling and conversion of dose from silicon to water, and methods for ion identification (Z) using machine learning. The main results of this dissertation are as follows: 1. Spatial resolution on the order of 0.1 cm is required for active space radiation detectors to have high confidence in identifying individual particles, i.e., to eliminate coincident events. 2. Energy resolution of a detector system will be limited by energy straggling effects and the conversion of dose in silicon to dose in biological tissue (water). 3. Machine learning methods show strong promise for identification of ion charge (Z) with simple detector designs.

  19. Antipsychotic treatment dosing profile in patients with schizophrenia evaluated with electronic monitoring (MEMS®).

    PubMed

    Acosta, Francisco J; Ramallo-Fariña, Yolanda; Bosch, Esperanza; Mayans, Teresa; Rodríguez, Carlos J; Caravaca, Ana

    2013-05-01

    Although the Medication Event Monitoring System (MEMS®) device offers accurate information on treatment dosing profile, such profile has never been studied in patients with schizophrenia. Enhancing our knowledge on this issue would help in developing intervention strategies to improve adherence to antipsychotic treatment in these patients. 74 outpatients with schizophrenia were monitored with the MEMS device for a 3-month period, for evaluation of antipsychotic treatment dosing profile, possible influence of medication schedule-related variables, adherence to treatment--considering dose intake within prescribed timeframes--and possible Hawthorne's effect of using the MEMS device. Dose-omission gaps occurred in 18.7% of monitoring days, most frequently during weekends, almost significantly. Almost one-third of prescribed doses were taken out of prescribed time. Neither the prescribed number of daily doses nor the indicated time of the day for dose intake (breakfast, dinner), were associated with correct antipsychotic dosing. Excess-dose was rare in general, and more frequent out of prescribed dose timeframe. No Hawthorne's effect was found for the MEMS device. Adherence reached only 35% according to a definition that included dose intake within prescribed timeframes. Antipsychotic treatment dosing was considerably irregular among patients with schizophrenia. Strategies to reduce dose-omission gaps and increase dosing within prescribed timeframes seem to be necessary. Gaining knowledge on precise oral antipsychotic dosing profiles or the influence of schedule-related variables may be useful to design strategies towards enhancing adherence. There appears to be no Hawthorne's effect associated with the use of MEMS devices in outpatients with schizophrenia. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Glucose control and use of continuous glucose monitoring in the intensive care unit: a critical review.

    PubMed

    De Block, Christophe; Manuel-y-Keenoy, Begoña; Rogiers, Peter; Jorens, Philippe; Van Gaal, Luc

    2008-08-01

    Stress hyperglycemia recently became a major therapeutic target in the Intensive Care Unit (ICU) since it occurs in most critically ill patients and is associated with adverse outcome, including increased mortality. Intensive insulin therapy to achieve normoglycemia may reduce mortality, morbidity and the length of ICU and in-hospital stay. However, obtaining normoglycemia requires extensive efforts from the medical staff, including frequent glucose monitoring and adjustment of insulin dose. Current insulin titration is based upon discrete glucose measurements, which may miss fast changes in glycemia and which does not give a full picture of overall glycemic control. Recent evidence suggests that continuous monitoring of glucose levels may help to signal glycemic excursions and eventually to optimize insulin titration in the ICU. In this review we will summarise monitoring and treatment strategies to achieve normoglycemia in the ICU, with special emphasis on the possible advantages of continuous glucose monitoring.

  1. Methylxanthine Drug Monitoring with Wearable Sweat Sensors.

    PubMed

    Tai, Li-Chia; Gao, Wei; Chao, Minghan; Bariya, Mallika; Ngo, Quynh P; Shahpar, Ziba; Nyein, Hnin Y Y; Park, Hyejin; Sun, Junfeng; Jung, Younsu; Wu, Eric; Fahad, Hossain M; Lien, Der-Hsien; Ota, Hiroki; Cho, Gyoujin; Javey, Ali

    2018-06-01

    Drug monitoring plays crucial roles in doping control and precision medicine. It helps physicians tailor drug dosage for optimal benefits, track patients' compliance to prescriptions, and understand the complex pharmacokinetics of drugs. Conventional drug tests rely on invasive blood draws. While urine and sweat are attractive alternative biofluids, the state-of-the-art methods require separate sample collection and processing steps and fail to provide real-time information. Here, a wearable platform equipped with an electrochemical differential pulse voltammetry sensing module for drug monitoring is presented. A methylxanthine drug, caffeine, is selected to demonstrate the platform's functionalities. Sweat caffeine levels are monitored under various conditions, such as drug doses and measurement time after drug intake. Elevated sweat caffeine levels upon increasing dosage and confirmable caffeine physiological trends are observed. This work leverages a wearable sweat sensing platform toward noninvasive and continuous point-of-care drug monitoring and management. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Standards, documents of relevance and directives in individual monitoring: is European individual monitoring in compliance with standards?

    PubMed

    Fantuzzi, E

    2007-01-01

    Individual monitoring services (IMS) in Europe do not comply with the same legal or approval requirements. Anyway, a degree of harmonisation existing in individual monitoring practices in Europe has been achieved mainly thanks to documents as standards or international recommendations, which with different weight represent invaluable vehicles of condensed information transfer. However, implementation of standards is not straightforward and harmonisation is not directly a consequence. Somehow, 'harmony' is needed also in standards: IEC and ISO standards, on performance requirements for dosemeters sometimes have different approaches (i.e. performance criteria). Moreover, standards do not all refer to reliability, and therefore being in compliance with standards does not by itself assure that dose results are reliable. Standards are not the only reference documents for an IMS. EURADOS working group on 'Harmonisation of Individual Monitoring in Europe', who has been active in the years 2001-2004, suggested a classification of publication on individual monitoring, distinguishing between standards and documents of relevance, which can be both national and international. None of the two categories are mandatory unless specified in legislation. The Council Directive 96/29/EURATOM and its implementation in each EU Member States has fostered harmonisation of the approach (i.e. approval of dosimetric services) and of the reference quantities for individual monitoring within EU, but national legislation still allow substantial differences in individual monitoring from country to country.

  3. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT

    PubMed Central

    Halliburton, Sandra S.; Abbara, Suhny; Chen, Marcus Y.; Gentry, Ralph; Mahesh, Mahadevappa; Raff, Gilbert L.; Shaw, Leslee J.; Hausleiter, Jörg

    2012-01-01

    Over the last few years, computed tomography (CT) has developed into a standard clinical test for a variety of cardiovascular conditions. The emergence of cardiovascular CT during a period of dramatic increase in radiation exposure to the population from medical procedures and heightened concern about the subsequent potential cancer risk has led to intense scrutiny of the radiation burden of this new technique. This has hastened the development and implementation of dose reduction tools and prompted closer monitoring of patient dose. In an effort to aid the cardiovascular CT community in incorporating patient-centered radiation dose optimization and monitoring strategies into standard practice, the Society of Cardiovascular Computed Tomography has produced a guideline document to review available data and provide recommendations regarding interpretation of radiation dose indices and predictors of risk, appropriate use of scanner acquisition modes and settings, development of algorithms for dose optimization, and establishment of procedures for dose monitoring. PMID:21723512

  4. Effect of radiocesium transfer on ambient dose rate in forest environments affected by the Fukushima Nuclear Power Plant accident

    NASA Astrophysics Data System (ADS)

    Kato, H.

    2015-12-01

    We investigated the transfer of canopy-intercepted radiocesium to the forest floor during 3 years following the Fukushima Daiichi Nuclear Power Plant accident. The cesium-137 (Cs-137) contents in throughfall, stemflow, and litterfall were monitored in two coniferous stands (plantation of Japanese cedar) and a deciduous broad-leaved forest stand (Japanese oak with red pine). We also measured the ambient dose rate (ADR) at different heights in the forest using a survey meter and a portable Ge gamma-ray detector. Total Cs-137 deposition flux from the canopy to forest floor for the mature cedar, young cedar, and the mixed broad-leaved stands were 166 kBq/m2, 174 kBq/m2, and 60 kBq/m2, respectively. These values correspond to 38%, 40% and 13% of total atmospheric input after the accident. The ambient dose rate in forest exhibited height dependency and its vertical distribution varied with forest type and stand age. The ambient dose rate showed an exponential decrease with time for all the forest sites, however the decreasing trend differed depending on the height of dose measurement and forest type. The ambient dose rate at the canopy (approx. 10 m-height) decreased faster than that expected from physical decay of the two radiocesium isotopes, whereas those at the forest floor varied between the three forest stands. The radiocesium deposition via throughfall seemed to increase ambient dose rate during the first 200 days after the accident, however there was no clear relationship between litterfall and ambient dose rate since 400 days after the accident. These data suggested that the ambient dose rate in forest environment varied both spatially and temporally reflecting the transfer of radiocesium from canopy to forest floor. However, further monitoring investigation and analysis are required to determine the effect of litterfall on long-term trend of ambient dose rate in forest environments.

  5. RFID tracking of sublethal effects of two neonicotinoid insecticides on the foraging behavior of Apis mellifera.

    PubMed

    Schneider, Christof W; Tautz, Jürgen; Grünewald, Bernd; Fuchs, Stefan

    2012-01-01

    The development of insecticides requires valid risk assessment procedures to avoid causing harm to beneficial insects and especially to pollinators such as the honeybee Apis mellifera. In addition to testing according to current guidelines designed to detect bee mortality, tests are needed to determine possible sublethal effects interfering with the animal's vitality and behavioral performance. Several methods have been used to detect sublethal effects of different insecticides under laboratory conditions using olfactory conditioning. Furthermore, studies have been conducted on the influence insecticides have on foraging activity and homing ability which require time-consuming visual observation. We tested an experimental design using the radiofrequency identification (RFID) method to monitor the influence of sublethal doses of insecticides on individual honeybee foragers on an automated basis. With electronic readers positioned at the hive entrance and at an artificial food source, we obtained quantifiable data on honeybee foraging behavior. This enabled us to efficiently retrieve detailed information on flight parameters. We compared several groups of bees, fed simultaneously with different dosages of a tested substance. With this experimental approach we monitored the acute effects of sublethal doses of the neonicotinoids imidacloprid (0.15-6 ng/bee) and clothianidin (0.05-2 ng/bee) under field-like circumstances. At field-relevant doses for nectar and pollen no adverse effects were observed for either substance. Both substances led to a significant reduction of foraging activity and to longer foraging flights at doses of ≥0.5 ng/bee (clothianidin) and ≥1.5 ng/bee (imidacloprid) during the first three hours after treatment. This study demonstrates that the RFID-method is an effective way to record short-term alterations in foraging activity after insecticides have been administered once, orally, to individual bees. We contribute further information on the understanding of how honeybees are affected by sublethal doses of insecticides.

  6. RFID Tracking of Sublethal Effects of Two Neonicotinoid Insecticides on the Foraging Behavior of Apis mellifera

    PubMed Central

    Schneider, Christof W.; Tautz, Jürgen; Grünewald, Bernd; Fuchs, Stefan

    2012-01-01

    The development of insecticides requires valid risk assessment procedures to avoid causing harm to beneficial insects and especially to pollinators such as the honeybee Apis mellifera. In addition to testing according to current guidelines designed to detect bee mortality, tests are needed to determine possible sublethal effects interfering with the animal's vitality and behavioral performance. Several methods have been used to detect sublethal effects of different insecticides under laboratory conditions using olfactory conditioning. Furthermore, studies have been conducted on the influence insecticides have on foraging activity and homing ability which require time-consuming visual observation. We tested an experimental design using the radiofrequency identification (RFID) method to monitor the influence of sublethal doses of insecticides on individual honeybee foragers on an automated basis. With electronic readers positioned at the hive entrance and at an artificial food source, we obtained quantifiable data on honeybee foraging behavior. This enabled us to efficiently retrieve detailed information on flight parameters. We compared several groups of bees, fed simultaneously with different dosages of a tested substance. With this experimental approach we monitored the acute effects of sublethal doses of the neonicotinoids imidacloprid (0.15–6 ng/bee) and clothianidin (0.05–2 ng/bee) under field-like circumstances. At field-relevant doses for nectar and pollen no adverse effects were observed for either substance. Both substances led to a significant reduction of foraging activity and to longer foraging flights at doses of ≥0.5 ng/bee (clothianidin) and ≥1.5 ng/bee (imidacloprid) during the first three hours after treatment. This study demonstrates that the RFID-method is an effective way to record short-term alterations in foraging activity after insecticides have been administered once, orally, to individual bees. We contribute further information on the understanding of how honeybees are affected by sublethal doses of insecticides. PMID:22253863

  7. Bone mineral measurement using dual energy x ray densitometry

    NASA Technical Reports Server (NTRS)

    Smith, Steven W.

    1989-01-01

    Bone mineral measurements before and after space missions have shown that weightlessness greatly accelerates bone demineralization. Bone mineral losses as high as 1 to 3 percent per month were reported. Highly precise instrumentation is required to monitor this loss and thereby test the efficacy of treatment. During the last year, a significant improvement was made in Dual-Photon Absorptiometry by replacing the radioactive source with an x ray tube. Advantages of this system include: better precision, lower patient dose, better spacial resolution, and shorter scan times. The high precision and low radiation dose of this technique will allow detection of bone mineral changes of less than 1 percent with measurements conducted directly at the sites of interest. This will allow the required bone mineral studies to be completed in a shorter time with greater confidence.

  8. Dose-response relationships for environmentally mediated infectious disease transmission models

    PubMed Central

    Eisenberg, Joseph N. S.

    2017-01-01

    Environmentally mediated infectious disease transmission models provide a mechanistic approach to examining environmental interventions for outbreaks, such as water treatment or surface decontamination. The shift from the classical SIR framework to one incorporating the environment requires codifying the relationship between exposure to environmental pathogens and infection, i.e. the dose–response relationship. Much of the work characterizing the functional forms of dose–response relationships has used statistical fit to experimental data. However, there has been little research examining the consequences of the choice of functional form in the context of transmission dynamics. To this end, we identify four properties of dose–response functions that should be considered when selecting a functional form: low-dose linearity, scalability, concavity, and whether it is a single-hit model. We find that i) middle- and high-dose data do not constrain the low-dose response, and different dose–response forms that are equally plausible given the data can lead to significant differences in simulated outbreak dynamics; ii) the choice of how to aggregate continuous exposure into discrete doses can impact the modeled force of infection; iii) low-dose linear, concave functions allow the basic reproduction number to control global dynamics; and iv) identifiability analysis offers a way to manage multiple sources of uncertainty and leverage environmental monitoring to make inference about infectivity. By applying an environmentally mediated infectious disease model to the 1993 Milwaukee Cryptosporidium outbreak, we demonstrate that environmental monitoring allows for inference regarding the infectivity of the pathogen and thus improves our ability to identify outbreak characteristics such as pathogen strain. PMID:28388665

  9. SU-E-T-110: An Investigation On Monitor Unit Threshold and Effects On IMPT Delivery in Proton Pencil Beam Planning System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Ding, X; Syh, J

    2015-06-15

    Purpose: An approved proton pencil beam scanning (PBS) treatment plan might not be able to deliver because of existed extremely low monitor unit per beam spot. A dual hybrid plan with higher efficiency of higher spot monitor unit and the efficacy of less number of energy layers were searched and optimized. The range of monitor unit threshold setting was investigated and the plan quality was evaluated by target dose conformity. Methods: Certain limitations and requirements need to be checks and tested before a nominal proton PBS treatment plan can be delivered. The plan needs to be met the machine characterization,more » specification in record and verification to deliver the beams. Minimal threshold of monitor unit, e.g. 0.02, per spot was set to filter the low counts and plan was re-computed. Further MU threshold increment was tested in sequence without sacrificing the plan quality. The number of energy layer was also alternated due to elimination of low count layer(s). Results: Minimal MU/spot threshold, spot spacing in each energy layer and total number of energy layer and the MU weighting of beam spots of each beam were evaluated. Plan optimization between increases of the spot MU (efficiency) and less energy layers of delivery (efficacy) was adjusted. 5% weighting limit of total monitor unit per beam was feasible. Scarce spreading of beam spots was not discouraging as long as target dose conformity within 3% criteria. Conclusion: Each spot size is equivalent to the relative dose in the beam delivery system. The energy layer is associated with the depth of the targeting tumor. Our work is crucial to maintain the best possible quality plan. To keep integrity of all intrinsic elements such as spot size, spot number, layer number and the carried weighting of spots in each layer is important in this study.« less

  10. [Estimation of effective doses derived from radon in selected SPA centers that use geothermal waters based on the information of radon concentrations].

    PubMed

    Walczak, Katarzyna; Zmyślony, Marek

    2013-01-01

    Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers), Iran (5), China (4) and India (5). Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m3 of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings). In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program.

  11. Immunocontraception for Managing Feral Cattle in Hong Kong

    PubMed Central

    Massei, Giovanna; Koon, Ka-Kei; Benton, Steven; Brown, Richard; Gomm, Matt; Orahood, Darcy S.; Pietravalle, Stéphane; Eckery, Douglas C.

    2015-01-01

    Conflicts between human interests and feral cattle in Hong Kong derive from growing numbers of free-roaming cattle. Public antipathy towards lethal population control led the local authorities to consider fertility control to reduce cattle numbers. This study assessed the potential side effects of the immunocontraceptive GonaCon on individual female cattle and established the effectiveness of GonaCon to induce infertility. We evaluated GonaCon in 34 captive cattle assigned to four groups: Control administered a sham solution; Webbed (surgically sterilized through removal of the oviducts), administered one dose of GonaCon; Webbed, administered one dose of GonaCon and a booster dose three months later, and Treated, administered one dose of GonaCon. The side effects of GonaCon were assessed by monitoring injection site, body weight, body condition, size of lymph nodes, body temperature, and feeding behaviour 1 week and 1, 3, 6, 9 and 12 months after vaccination and by haematological and biochemical variables at vaccination and three months post-vaccination. The effectiveness of GonaCon to cause infertility was monitored by quantifying anti-GnRH antibody titres and by using kits to detect cycling and pregnancy. GonaCon-treated cattle showed no injection site reaction, limping, or abnormal behaviour. No differences were observed in all physiological and welfare indicators between control and vaccinated cattle. All control cattle and 4 of the 12 cattle in the Treated group became pregnant. Cattle administered a booster dose had higher anti-GnRH antibody titres than cattle that received one dose. We concluded that GonaCon does not compromise the animals’ welfare and is effective in reducing fertility in cattle. A booster dose is likely to increase the duration of infertility. Further studies are required to assess the feasibility and costs of immunocontraception for controlling free-roaming cattle populations. PMID:25856283

  12. Immunocontraception for managing feral cattle in Hong Kong.

    PubMed

    Massei, Giovanna; Koon, Ka-Kei; Benton, Steven; Brown, Richard; Gomm, Matt; Orahood, Darcy S; Pietravalle, Stéphane; Eckery, Douglas C

    2015-01-01

    Conflicts between human interests and feral cattle in Hong Kong derive from growing numbers of free-roaming cattle. Public antipathy towards lethal population control led the local authorities to consider fertility control to reduce cattle numbers. This study assessed the potential side effects of the immunocontraceptive GonaCon on individual female cattle and established the effectiveness of GonaCon to induce infertility. We evaluated GonaCon in 34 captive cattle assigned to four groups: Control administered a sham solution; Webbed (surgically sterilized through removal of the oviducts), administered one dose of GonaCon; Webbed, administered one dose of GonaCon and a booster dose three months later, and Treated, administered one dose of GonaCon. The side effects of GonaCon were assessed by monitoring injection site, body weight, body condition, size of lymph nodes, body temperature, and feeding behaviour 1 week and 1, 3, 6, 9 and 12 months after vaccination and by haematological and biochemical variables at vaccination and three months post-vaccination. The effectiveness of GonaCon to cause infertility was monitored by quantifying anti-GnRH antibody titres and by using kits to detect cycling and pregnancy. GonaCon-treated cattle showed no injection site reaction, limping, or abnormal behaviour. No differences were observed in all physiological and welfare indicators between control and vaccinated cattle. All control cattle and 4 of the 12 cattle in the Treated group became pregnant. Cattle administered a booster dose had higher anti-GnRH antibody titres than cattle that received one dose. We concluded that GonaCon does not compromise the animals' welfare and is effective in reducing fertility in cattle. A booster dose is likely to increase the duration of infertility. Further studies are required to assess the feasibility and costs of immunocontraception for controlling free-roaming cattle populations.

  13. Radioactivity Risk Assessment of Radon and Gamma Dose at One Uranium Tailings Pond in China

    NASA Astrophysics Data System (ADS)

    Lou, Yalong; Liu, Yong; Peng, Guowen; Zhao, Guodong; Zhang, Yan; Yang, Zhu

    2018-01-01

    A year-long monitoring of gamma radiation effective dose rate and radon concentration had been done in the reservoir area of one uranium tailings pond in Hunan province (The monitoring area included indoor and outdoor area of residential buildings and workshops, tailings dam slope). Afterwards, the annual effective radiation dose of the people in that radiation environment had been calculated based on the results of monitoring, as well as a radiation risk assessment. According to the assessment, gamma radiation effective dose rate and radon concentration in the monitoring area were low, and the annual effective radiation dose was far below the international standard (30mSv), which showed that the radiation would not put the people’s health at risk. However, the annual effective radiation dose of gamma was far above that of radon in the area of uranium tailings pond; therefore, it’s advisable to take quarantine measures in in the area of uranium tailings pond to keep the surrounding residents away from unnecessary ionizing radiation.

  14. A multicenter experience with generic tacrolimus conversion.

    PubMed

    McDevitt-Potter, Lisa M; Sadaka, Basma; Tichy, Eric M; Rogers, Christin C; Gabardi, Steven

    2011-09-27

    The first generic tacrolimus product gained Food and Drug Administration approval in August 2009. This prospective, observational trial sought to determine the need for dose titrations and measure drug cost savings on conversion to generic tacrolimus. Transplant recipients on stable tacrolimus doses were converted from brand to generic tacrolimus on a mg:mg basis. Data were collected at the time of generic conversion (study arm) and at a time point exactly 6 months before conversion (control arm) for all subjects. Seventy conversions from four centers are reported. Subjects were a mean of 70 months after kidney (n=37), liver (n=28), or multiorgan (n=5) transplant. In the study arm, mean tacrolimus doses were 4.4 and 4.5 mg/d and mean tacrolimus trough concentrations were 5.8 and 5.9 ng/mL before and after conversion, respectively. In the control arm, mean tacrolimus doses were 4.6 and 4.6 mg/d and mean tacrolimus trough concentrations were 6.1 and 5.9 ng/mL before and after the control time point, respectively. Dose titrations occurred in five patients (7%) in the control arm and 15 patients (21%) in the study arm (P=0.028). Mean monthly drug costs were $645 for brand, $593 for generic, and $595 for generic after dose titrations. Mean monthly patient copays were $38 for brand and $15 for generic. These cumulative data show that dose requirements and trough levels are similar between brand and generic tacrolimus and that generic substitution allows for savings. However, postconversion monitoring is prudent as patients may require dose titration.

  15. Optimizing the Anti-VEGF Treatment Strategy for Neovascular Age-Related Macular Degeneration: From Clinical Trials to Real-Life Requirements.

    PubMed

    Mantel, Irmela

    2015-06-01

    This Perspective discusses the pertinence of variable dosing regimens with anti-vascular endothelial growth factor (VEGF) for neovascular age-related macular degeneration (nAMD) with regard to real-life requirements. After the initial pivotal trials of anti-VEGF therapy, the variable dosing regimens pro re nata (PRN), Treat-and-Extend, and Observe-and-Plan, a recently introduced regimen, aimed to optimize the anti-VEGF treatment strategy for nAMD. The PRN regimen showed good visual results but requires monthly monitoring visits and can therefore be difficult to implement. Moreover, application of the PRN regimen revealed inferior results in real-life circumstances due to problems with resource allocation. The Treat-and-Extend regimen uses an interval based approach and has become widely accepted for its ease of preplanning and the reduced number of office visits required. The parallel development of the Observe-and-Plan regimen demonstrated that the future need for retreatment (interval) could be reliably predicted. Studies investigating the observe-and-plan regimen also showed that this could be used in individualized fixed treatment plans, allowing for dramatically reduced clinical burden and good outcomes, thus meeting the real life requirements. This progressive development of variable dosing regimens is a response to the real-life circumstances of limited human, technical, and financial resources. This includes an individualized treatment approach, optimization of the number of retreatments, a minimal number of monitoring visits, and ease of planning ahead. The Observe-and-Plan regimen achieves this goal with good functional results. Translational Relevance: This perspective reviews the process from the pivotal clinical trials to the development of treatment regimens which are adjusted to real life requirements. The article discusses this translational process which- although not the classical interpretation of translation from fundamental to clinical research, but a subsequent process after the pivotal clinical trials - represents an important translational step from the clinical proof of efficacy to optimization in terms of patients' and clinics' needs. The related scientific procedure includes the exploration of the concept, evaluation of security, and finally proof of efficacy.

  16. Dosing adjustments in postpartum patients maintained on buprenorphine or methadone.

    PubMed

    Jones, Hendrée E; Johnson, Rolley E; O'Grady, Kevin E; Jasinski, Donald R; Tuten, Michelle; Milio, Lorraine

    2008-06-01

    Scant scientific attention has been given to examining the need for agonist medication dose changes in the postpartum period. Study objectives were: 1) to determine the need for medication dose adjustments in participants stabilized on buprenorphine or methadone 3 weeks before and 4 weeks after delivery, and 2) to evaluate the need for methadone dose adjustments during the first 7 days in participants transferred from buprenorphine to methadone at 5 weeks postpartum. Participants were opioid-dependent pregnant women who had completed a randomized, double-blind, double-dummy, flexible dosing comparison of buprenorphine to methadone. Participants received a stable dose of methadone (N = 10) or buprenorphine (N = 8) before and 4 weeks after delivery. Buprenorphine-maintained participants were transferred to methadone at 5 weeks postpartum. There were no significant differences predelivery and/or postdelivery between the buprenorphine and methadone conditions in the mean ratings of dose adequacy, "liking," "hooked," and "craving" of heroin or cocaine. Patient response to the conversion from buprenorphine to methadone seems variable. Buprenorphine-maintained participants required dose changes postpartum only after they transferred to methadone. Regardless of type of medication, postpartum patients should be monitored for signs of overmedication.

  17. Adequacy of Fixed-Dose Heparin Infusions for Venous Thromboembolism Prevention after Microsurgical Procedures.

    PubMed

    Bertolaccini, Corinne M; Prazak, Ann Marie B; Agarwal, Jayant; Goodwin, Isak A; Rockwell, W Bradford; Pannucci, Christopher J

    2018-05-22

     In microvascular surgery, patients often receive unfractionated heparin infusions to minimize risk for microvascular thrombosis. Patients who receive intravenous (IV) heparin are believed to have adequate prophylaxis against venous thromboembolism (VTE). Whether a fixed dose of IV heparin provides detectable levels of anticoagulation, or whether the "one size fits all" approach provides adequate prophylaxis against VTE remains unknown. This study examined the pharmacodynamics of fixed-dose heparin infusions and the effects of real-time, anti-factor Xa (aFXa) level driven heparin dose adjustments.  This prospective clinical trial recruited adult microvascular surgery patients placed on a fixed-dose (500 units/h) unfractionated heparin infusion during their initial microsurgical procedure. Steady-state aFXa levels, a marker of unfractionated heparin efficacy and safety, were monitored. Patients with out-of-range aFXa levels received protocol-driven real-time dose adjustments. Outcomes of interest included aFXa levels in response to heparin 500 units/h, number of dose adjustments required to achieve goal aFXa levels, time to reach goal aFXa level, and 90-day clinically relevant bleeding and VTE.  Twenty patients were recruited prospectively. None of 20 patients had any detectable level of anticoagulation in response to heparin infusions at 500 units/h. The median number of dose adjustments required to reach goal level was five, and median weight-based dose to reach goal level was 11.8 units/kg/h. Real-time dose adjustments significantly increased the proportion of patients with in-range levels (60 vs. 0%, p  = 0.0001). The 90-day VTE rate was 5% and 90-day clinically relevant bleeding rate was 5%.  Fixed-dose heparin infusions at a rate of 500 units/h do not provide a detectable level of anticoagulation after microsurgical procedures and are insufficient for the majority of patients who require VTE prophylaxis. Weight-based heparin infusions at 10 to 12 units/kg/h deserve future study in patients undergoing microsurgical procedures to increase the proportion of patients receiving adequate VTE prophylaxis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Evaluation of an electronic nose for odorant and process monitoring of alkaline-stabilized biosolids production.

    PubMed

    Romero-Flores, Adrian; McConnell, Laura L; Hapeman, Cathleen J; Ramirez, Mark; Torrents, Alba

    2017-11-01

    Electronic noses have been widely used in the food industry to monitor process performance and quality control, but use in wastewater and biosolids treatment has not been fully explored. Therefore, we examined the feasibility of an electronic nose to discriminate between treatment conditions of alkaline stabilized biosolids and compared its performance with quantitative analysis of key odorants. Seven lime treatments (0-30% w/w) were prepared and the resultant off-gas was monitored by GC-MS and by an electronic nose equipped with ten metal oxide sensors. A pattern recognition model was created using linear discriminant analysis (LDA) and principal component analysis (PCA) of the electronic nose data. In general, LDA performed better than PCA. LDA showed clear discrimination when single tests were evaluated, but when the full data set was included, discrimination between treatments was reduced. Frequency of accurate recognition was tested by three algorithms with Euclidan and Mahalanobis performing at 81% accuracy and discriminant function analysis at 70%. Concentrations of target compounds by GC-MS were in agreement with those reported in literature and helped to elucidate the behavior of the pattern recognition via comparison of individual sensor responses to different biosolids treatment conditions. Results indicated that the electronic nose can discriminate between lime percentages, thus providing the opportunity to create classes of under-dosed and over-dosed relative to regulatory requirements. Full scale application will require careful evaluation to maintain accuracy under variable process and environmental conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sailer, Anna M., E-mail: karmanna@stanford.edu; Paulis, Leonie, E-mail: leonie.paulis@mumc.nl; Vergoossen, Laura

    PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to proceduremore » type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.« less

  20. Pharmacist-managed dose adjustment feedback using therapeutic drug monitoring of vancomycin was useful for patients with methicillin-resistant Staphylococcus aureus infections: a single institution experience

    PubMed Central

    Hirano, Ryuichi; Sakamoto, Yuichi; Kitazawa, Junichi; Yamamoto, Shoji; Tachibana, Naoki

    2016-01-01

    Background Vancomycin (VCM) requires dose adjustment based on therapeutic drug monitoring. At Aomori Prefectural Central Hospital, physicians carried out VCM therapeutic drug monitoring based on their experience, because pharmacists did not participate in the dose adjustment. We evaluated the impact of an Antimicrobial Stewardship Program (ASP) on attaining target VCM trough concentrations and pharmacokinetics (PK)/pharmacodynamics (PD) parameters in patients with methicillin-resistant Staphylococcus aureus (MRSA) infections. Materials and methods The ASP was introduced in April 2012. We implemented a prospective audit of prescribed VCM dosages and provided feedback based on measured VCM trough concentrations. In a retrospective pre- and postcomparison study from April 2007 to December 2011 (preimplementation) and from April 2012 to December 2014 (postimplementation), 79 patients were treated for MRSA infection with VCM, and trough concentrations were monitored (pre, n=28; post, n=51). In 65 patients (pre, n=15; post, n=50), 24-hour area under the concentration–time curve (AUC 0–24 h)/minimum inhibitory concentration (MIC) ratios were calculated. Results Pharmacist feedback, which included recommendations for changing dose or using alternative anti-MRSA antibiotics, was highly accepted during postimplementation (88%, 29/33). The number of patients with serum VCM concentrations within the therapeutic range (10–20 μg/mL) was significantly higher during postimplementation (84%, 43/51) than during preimplementation (39%, 11/28) (P<0.01). The percentage of patients who attained target PK/PD parameters (AUC 0–24 h/MIC >400) was significantly higher during postimplementation (84%, 42/50) than during preimplementation (53%, 8/15; P=0.013). There were no significant differences in nephrotoxicity or mortality rate. Conclusion Our ASP increased the percentage of patients that attained optimal VCM trough concentrations and PK/PD parameters, which contributed to the appropriate use of VCM in patients with MRSA infections. PMID:27789965

  1. Performance of a GM tube based environmental dose rate monitor operating in the Time-To-Count mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zickefoose, J.; Kulkarni, T.; Martinson, T.

    The events at the Fukushima Daiichi power plant in the aftermath of a natural disaster underline the importance of a large array of networked environmental monitors to cover areas around nuclear power plants. These monitors should meet a few basic criteria: have a uniform response over a wide range of gamma energies, have a uniform response over a wide range of incident angles, and have a large dynamic range. Many of these criteria are met if the probe is qualified to the international standard IEC 60532 (Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - Xmore » and gamma radiation of energy between 50 keV and 7 MeV), which specifically deals with energy response, angle of incidence, dynamic range, response time, and a number of environmental characteristics. EcoGamma is a dual GM tube environmental gamma radiation monitor designed specifically to meet the requirements of IEC 60532 and operate in the most extreme conditions. EcoGamma utilizes two energy compensated GM tubes operating with a Time-To-Count (TTC) collection algorithm. The TTC algorithm extends the lifetime and range of a GM tube significantly and allows the dual GM tube probe to achieve linearity over approximately 10 decades of gamma dose rate (from the Sv/hr range to 100 Sv/hr). In the TTC mode of operation, the GM tube is not maintained in a biased condition continuously. This is different from a traditional counting system where the GM tube is held at a constant bias continuously and the total number of strikes that the tube registers are counted. The traditional approach allows for good sensitivity, but does not lend itself to a long lifetime of the tube and is susceptible to linearity issues at high count rates. TTC on the other hand only biases the tube for short periods of time and in effect measures the time between events, which is statistically representative of the total strike rate. Since the tube is not continually biased, the life of the tube is extended and the linearity is greatly improved. Testing has been performed at Pacific Northwest National Laboratory (PNNL) in the USA and confirms compliance to IEC 60532 as well as linearity (± 10%) up to 100 Sv/hr. Furthermore, a network of EcoGamma probes may be linked through available supervisory software to provide a dose rate map of an area. This allows for real time monitoring of dose rates from one (or multiple) remote locations. (authors)« less

  2. Automated size-specific CT dose monitoring program: assessing variability in CT dose.

    PubMed

    Christianson, Olav; Li, Xiang; Frush, Donald; Samei, Ehsan

    2012-11-01

    The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED(adj)). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED(adj) between scanner models and across institutions. No significant difference was found between computer measurements of patient thickness and observer measurements (p = 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED(adj) that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED(adj) distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED(adj) (range: 9%-64%). Finally, a significant difference (up to 59%) in ED(adj) distributions was observed between institutions, indicating the potential for dose reduction. The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED(adj) were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

  3. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christianson, Olav; Li Xiang; Frush, Donald

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CTmore » imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED{sub adj} distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED{sub adj} (range: 9%-64%). Finally, a significant difference (up to 59%) in ED{sub adj} distributions was observed between institutions, indicating the potential for dose reduction. Conclusions: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED{sub adj} were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.« less

  4. Environmental monitoring, restoration and assessment: What have we learned

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, R.H.

    1990-01-01

    The Twenty-Eighth Hanford Symposium on Health and the Environment was held in Richland, Washington, October 16--19, 1989. The symposium was sponsored by the US Department of Energy and the Pacific Northwest Laboratory, operated by Battelle Memorial Institute. The symposium was organized to review and evaluate some of the monitoring and assessment programs that have been conducted or are currently in place. Potential health and environmental effects of energy-related and other industrial activities have been monitored and assessed at various government and private facilities for over three decades. Most monitoring is required under government regulations; some monitoring is implemented because facilitymore » operators consider it prudent practice. As a result of these activities, there is now a substantial radiological, physical, and chemical data base for various environmental components, both in the United States and abroad. Symposium participants, both platform and poster presenters, were asked to consider, among other topics, the following: Has the expenditure of millions of dollars for radiological monitoring and assessment activities been worth the effort How do we decide when enough monitoring is enough Can we adequately assess the impacts of nonradiological components -- both inorganic and organic -- of wastes Are current regulatory requirements too restrictive or too lenient Can monitoring and assessment be made more cost effective Papers were solicited in the areas of environmental monitoring; environmental regulations; remediation, restoration, and decommissioning; modeling and dose assessment; uncertainty, design, and data analysis; and data management and quality assurance. Individual reports are processed separately for the databases.« less

  5. Bispectral Index monitoring in cancer patients undergoing palliative sedation: a preliminary report.

    PubMed

    Monreal-Carrillo, Edith; Allende-Pérez, Silvia; Hui, David; García-Salamanca, Maria-Fernanda; Bruera, Eduardo; Verástegui, Emma

    2017-10-01

    Continuous palliative sedation (PS) is currently titrated based on clinical observation; however, it is often unclear if patients are still aware of their suffering. The aim of this prospective study is to characterize the level of consciousness in patients undergoing PS using Bispectral Index (BIS) monitoring. We enrolled consecutive patients with refractory symptoms requiring PS. We documented the level of sedation using Ramsay Sedation Scale (RSS) and BIS at 0, 2, 4, 6, 12, and 24 h during the first day of PS and examined their degree of association. Intravenous midazolam or propofol was titrated according to the sedation level. Twenty patients on PS were recruited and had BIS continuous monitoring. Delirium was the most frequent reason for PS (n = 15, 75%). The median time of sedation was 24.5 h (interquartile range 6-46). The average time to achieve the desired sedation level was 6 h, and dose titration was required in 80% of the cases. At baseline, 14 (70%) patients were considered to be awake according to RSS (i.e., 1-3) and 19 (95%) were awake according to BIS (i.e., >60%). This proportion decreased to 31 and 56% at 4 h, 27% and 53 at 6 h, and 22 and 33% at 24 h. RS and BIS had moderate correlation (rho = -0.58 to -0.65); however, a small proportion of patients were found to be awake by BIS (i.e., ≥60%) despite clinical observation (i.e., RSS 4-6) indicating otherwise. The BIS is a noninvasive, bedside, real-time continuous monitoring method that may facilitate the objective assessment of level of consciousness and dose titration in patients undergoing PS.

  6. Ammonia sanitization of blackwater for safe use as fertilizer.

    PubMed

    Fidjeland, Jörgen; Svensson, Sven-Erik; Vinnerås, Björn

    2015-01-01

    Source-separated blackwater from low-flush toilets contains plant-available nutrients and can be used as a fertilizer. The aim of the study was to evaluate the impact on pathogen inactivation when treating blackwater with urea and/or lime. Blackwater was spiked with Salmonella typhimurium, Escherichia coli O157, Enterococcus faecalis, and Ascaris suum eggs, and treated with urea and/or lime in concentrations up to 0.1% w/w. The bottles were kept in a storage facility (manure slurry tank) for 102 days while monitoring the pathogen concentrations. The treatment time needed to meet the requirement for Salmonella and E. coli reduction could be reduced at least six-fold. The enterococci were more persistent, and only the highest treatment doses had a significantly higher inactivation than the controls. The Ascaris egg viability was only reduced by around 50%, so higher urea/lime doses and/or longer treatment times are required to fulfill the treatment requirements of 3 log10 reductions of parasite eggs.

  7. Accurate heterogeneous dose calculation for lung cancer patients without high‐resolution CT densities

    PubMed Central

    Li, Jonathan G.; Liu, Chihray; Olivier, Kenneth R.; Dempsey, James F.

    2009-01-01

    The aim of this study was to investigate the relative accuracy of megavoltage photon‐beam dose calculations employing either five bulk densities or independent voxel densities determined by calibration of the CT Houndsfield number. Full‐resolution CT and bulk density treatment plans were generated for 70 lung or esophageal cancer tumors (66 cases) using a commercial treatment planning system with an adaptive convolution dose calculation algorithm (Pinnacle3, Philips Medicals Systems). Bulk densities were applied to segmented regions. Individual and population average densities were compared to the full‐resolution plan for each case. Monitor units were kept constant and no normalizations were employed. Dose volume histograms (DVH) and dose difference distributions were examined for all cases. The average densities of the segmented air, lung, fat, soft tissue, and bone for the entire set were found to be 0.14, 0.26, 0.89, 1.02, and 1.12 g/cm3, respectively. In all cases, the normal tissue DVH agreed to better than 2% in dose. In 62 of 70 DVHs of the planning target volume (PTV), agreement to better than 3% in dose was observed. Six cases demonstrated emphysema, one with bullous formations and one with a hiatus hernia having a large volume of gas. These required the additional assignment of density to the emphysemic lung and inflammatory changes to the lung, the regions of collapsed lung, the bullous formations, and the hernia gas. Bulk tissue density dose calculation provides an accurate method of heterogeneous dose calculation. However, patients with advanced emphysema may require high‐resolution CT studies for accurate treatment planning. PACS number: 87.53.Tf

  8. Adherence to HAART therapy measured by electronic monitoring in newly diagnosed HIV patients in Botswana.

    PubMed

    Vriesendorp, Reinout; Cohen, Adam; Kristanto, Paulus; Vrijens, Bernard; Rakesh, Pande; Anand, Bene; Iwebor, Henry Uchechukwaka; Stiekema, Jacobus

    2007-12-01

    This pilot study was designed to evaluate the feasibility and benefits of electronic adherence monitoring of antiretroviral medications in HIV patients who recently started Highly Active Anti Retroviral Therapy (HAART) in Francistown, Botswana and to compare this with self-reporting. Dosing histories were compiled electronically using Micro Electro Mechanical Systems (MEMS) monitors to evaluate adherence to prescribed therapies. Thirty patients enrolled in the antiretroviral treatment program were monitored over 6 weeks. These patients were all antiretroviral (ARV) naïve. After each visit (mean three times) to the pharmacy, the data compiled by the monitors were downloaded. Electronic monitoring of adherence was compared to patient self-reports of adherence. The mean individual medication adherence level measured with the electronic device was 85% (range 21-100%). The mean adherence level measured by means of self-reporting was 98% (range 70-100%). Medication prescribed on a once-a-day dose base was associated with a higher adherence level (97.9% for efavirenz) compared with a twice-a-day regimen (88.4% for Lamivudine/Zidovudine). It is feasible to assess treatment adherence of patients living in a low resource setting on HAART by using electronic monitors. Adherence, even in the early stages of treatment, appears to be insufficient in some patients and may be below the level required for continuous inhibition of viral replication. This approach may lead to improved targeting of counselling about their medication intake of such patients in order to prevent occurrence of resistant viral strains due to inadequate inhibition of viral replication. In this pilot study a significant difference between the data recorded through the electronic monitors and those provided by self-reporting was observed.

  9. Frequency and quality of radiation monitoring of construction workers at two gaseous diffusion plants.

    PubMed

    Bingham, Eula; Ringen, Knut; Dement, John; Cameron, Wilfrid; McGowan, William; Welch, Laura; Quinn, Patricia

    2006-09-01

    Construction workers were and are considered temporary workers at many construction sites. Since World War II, large numbers of construction workers were employed at U.S. Department of Energy nuclear weapons sites for periods ranging from a few days to over 30 years. These workers performed tasks during new construction and maintenance, repair, renovation, and demolition of existing facilities. Such tasks may involve emergency situations, and may entail opportunities for significant radiation exposures. This paper provides data from interviews with more than 750 construction workers at two gaseous diffusion plants (GDPs) at Paducah, Kentucky, and Portsmouth, Ohio regarding radiation monitoring practices. The aim was to determine the extent to which workers believed they were monitored during tasks involving potential radiation exposures. The adequacy of monitoring practices is important for two reasons: (a) Protecting workers from exposures: Construction workers were employed by sub-contractors, and may frequently been excluded from safety and health programs provided to permanent employees; and (b) Supporting claims for compensation: The Energy Employees Occupational Illness Compensation Program Act (EEOICPA) requires dose reconstruction of radiation exposures for most workers who file a claim regarding cancer. The use of monitoring data for radiation to qualify a worker means that there should be valid and complete monitoring during the work time at the various nuclear plants or workers may be unfairly denied compensation. The worker interviews from Paducah and Portsmouth were considered especially useful because these sites were designated as Special Exposure Cohorts (SECs) and the workers did not have to have a dose reconstruction to qualify for compensation for most cancers. Therefore, their responses were less likely to be affected by compensation concerns. Interview questions included asking for information regarding whether monitoring was performed, how often, and the maintenance (calibration) of monitoring equipment (devices).

  10. 78 FR 64030 - Monitoring Criteria and Methods To Calculate Occupational Radiation Doses

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0234] Monitoring Criteria and Methods To Calculate... regulatory guide (DG), DG-8031, ``Monitoring Criteria and Methods to Calculate Occupational Radiation Doses.'' This guide describes methods that the NRC staff considers acceptable for licensees to use to determine...

  11. Image-guided positioning and tracking.

    PubMed

    Ruan, Dan; Kupelian, Patrick; Low, Daniel A

    2011-01-01

    Radiation therapy aims at maximizing tumor control while minimizing normal tissue complication. The introduction of stereotactic treatment explores the volume effect and achieves dose escalation to tumor target with small margins. The use of ablative irradiation dose and sharp dose gradients requires accurate tumor definition and alignment between patient and treatment geometry. Patient geometry variation during treatment may significantly compromise the conformality of delivered dose and must be managed properly. Setup error and interfraction/intrafraction motion are incorporated in the target definition process by expanding the clinical target volume to planning target volume, whereas the alignment between patient and treatment geometry is obtained with an adaptive control process, by taking immediate actions in response to closely monitored patient geometry. This article focuses on the monitoring and adaptive response aspect of the problem. The term "image" in "image guidance" will be used in a most general sense, to be inclusive of some important point-based monitoring systems that can be considered as degenerate cases of imaging. Image-guided motion adaptive control, as a comprehensive system, involves a hierarchy of decisions, each of which balances simplicity versus flexibility and accuracy versus robustness. Patient specifics and machine specifics at the treatment facility also need to be incorporated into the decision-making process. Identifying operation bottlenecks from a system perspective and making informed compromises are crucial in the proper selection of image-guidance modality, the motion management mechanism, and the respective operation modes. Not intended as an exhaustive exposition, this article focuses on discussing the major issues and development principles for image-guided motion management systems. We hope these information and methodologies will facilitate conscientious practitioners to adopt image-guided motion management systems accounting for patient and institute specifics and to embrace advances in knowledge and new technologies subsequent to the publication of this article.

  12. Oral dosing of chemical indicators for in vivo monitoring of Ca2+ dynamics in insect muscle.

    PubMed

    Ferdinandus; Arai, Satoshi; Ishiwata, Shin'ichi; Suzuki, Madoka; Sato, Hirotaka

    2015-01-01

    This paper proposes a remarkably facile staining protocol to visually investigate dynamic physiological events in insect tissues. We attempted to monitor Ca2+ dynamics during contraction of electrically stimulated living muscle. Advances in circuit miniaturization and insect neuromuscular physiology have enabled the hybridization of living insects and man-made electronic components, such as microcomputers, the result of which has been often referred as a Living Machine, Biohybrid, or Cyborg Insect. In order for Cyborg Insects to be of practical use, electrical stimulation parameters need to be optimized to induce desired muscle response (motor action) and minimize the damage in the muscle due to the electrical stimuli. Staining tissues and organs as well as measuring the dynamics of chemicals of interest in muscle should be conducted to quantitatively and systematically evaluate the effect of various stimulation parameters on the muscle response. However, existing staining processes require invasive surgery and/or arduous procedures using genetically encoded sensors. In this study, we developed a non-invasive and remarkably facile method for staining, in which chemical indicators can be orally administered (oral dosing). A chemical Ca2+ indicator was orally introduced into an insect of interest via food containing the chemical indicator and the indicator diffused from the insect digestion system to the target muscle tissue. We found that there was a positive relationship between the fluorescence intensity of the indicator and the frequency of electrical stimulation which indicates the orally dosed indicator successfully monitored Ca2+ dynamics in the muscle tissue. This oral dosing method has a potential to globally stain tissues including neurons, and investigating various physiological events in insects.

  13. Oral Dosing of Chemical Indicators for In Vivo Monitoring of Ca2+ Dynamics in Insect Muscle

    PubMed Central

    Ferdinandus; Arai, Satoshi; Ishiwata, Shin’ichi; Suzuki, Madoka; Sato, Hirotaka

    2015-01-01

    This paper proposes a remarkably facile staining protocol to visually investigate dynamic physiological events in insect tissues. We attempted to monitor Ca2+ dynamics during contraction of electrically stimulated living muscle. Advances in circuit miniaturization and insect neuromuscular physiology have enabled the hybridization of living insects and man-made electronic components, such as microcomputers, the result of which has been often referred as a Living Machine, Biohybrid, or Cyborg Insect. In order for Cyborg Insects to be of practical use, electrical stimulation parameters need to be optimized to induce desired muscle response (motor action) and minimize the damage in the muscle due to the electrical stimuli. Staining tissues and organs as well as measuring the dynamics of chemicals of interest in muscle should be conducted to quantitatively and systematically evaluate the effect of various stimulation parameters on the muscle response. However, existing staining processes require invasive surgery and/or arduous procedures using genetically encoded sensors. In this study, we developed a non-invasive and remarkably facile method for staining, in which chemical indicators can be orally administered (oral dosing). A chemical Ca2+ indicator was orally introduced into an insect of interest via food containing the chemical indicator and the indicator diffused from the insect digestion system to the target muscle tissue. We found that there was a positive relationship between the fluorescence intensity of the indicator and the frequency of electrical stimulation which indicates the orally dosed indicator successfully monitored Ca2+ dynamics in the muscle tissue. This oral dosing method has a potential to globally stain tissues including neurons, and investigating various physiological events in insects. PMID:25590329

  14. Clinical Utility of the Modified Segmental Boost Technique for Treatment of the Pelvis and Inguinal Nodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moran, M.S., E-mail: meena.moran@yale.ed; Yale New Haven Hospital, New Haven, Connecticut and William W. Backus Hospital, Norwich, Connecticut; Castrucci, W.A.

    2010-03-15

    Purpose: Low-lying pelvic malignancies often require simultaneous radiation to pelvis and inguinal nodes. We previously reported improved homogeneity with the modified segmental boost technique (MSBT) compared to that with traditional methods, using phantom models. Here we report our institutional clinical experience with MSBT. Methods and Materials: MSBT patients from May 2001 to March 2007 were evaluated. Parameters analyzed included isocenter/multileaf collimation shifts, time per fraction (four fields), monitor units (MU)/fraction, femoral doses, maximal dose relative to body mass index, and inguinal node depth. In addition, a dosimetric comparison of the MSBT versus intensity modulated radiation therapy (IMRT) was conducted. Results:more » Of the 37 MSBT patients identified, 32 were evaluable. Port film adjustments were required in 6% of films. Median values for each analyzed parameter were as follows: MU/fraction, 298 (range, 226-348); delivery time, 4 minutes; inguinal depth, 4.5 cm; volume receiving 45 Gy (V45), 7%; V27.5, 87%; body mass index, 25 (range, 16.0-33.8). Inguinal dose was 100% in all cases; in-field inhomogeneity ranged from 111% to 118%. IMRT resulted in significantly decreased dose to normal tissue but required more time for treatment planning and a higher number of MUs (1,184 vs. 313 MU). Conclusions: In our clinical experience, the mono-isocentric MSBT provides a high degree of accuracy, improved homogeneity compared with traditional techniques, ease of simulation, treatment planning, treatment delivery, and acceptable femoral doses for pelvic/inguinal radiation fields requiring 45 to 50.4 Gy. In addition, the MSBT delivers a relatively uniform dose distribution throughout the treatment volume, despite varying body habitus. Clinical scenarios for the use of MSBT vs. intensity-modulated radiation therapy are discussed. To our knowledge, this is the first study reporting the utility of MSBT in the clinical setting.« less

  15. Adverse events following immunisation with bacille Calmette-Guérin vaccination: baseline data to inform monitoring in Australia following introduction of new unregistered BCG vaccine.

    PubMed

    Hendry, Alexandra J; Dey, Aditi; Beard, Frank H; Khandaker, Gulam; Hill, Richard; Macartney, Kristine K

    2016-12-24

    In recent years there has been a global shortage of bacille Calmette-Guérin (BCG) vaccine and, from September 2012, unregistered vaccines have needed to be used in Australia (a Danish product initially until the end of 2015, and a Polish product used in some jurisdictions from early 2016). We examined rates and types of adverse events following immunisation (AEFI) with BCG vaccine reported to the Therapeutic Goods Administration between 2009 and 2014 in children aged less than 7 years. Reporting rates of AEFI with BCG vaccine increased from 87 per 100,000 doses (registered Sanofi Pasteur product) in 2009 to 201 per 100,000 doses (unregistered Danish Statens Serum Institute product) in 2014, with Victoria having the highest rate each year. Substantial variation between jurisdictions exists, suggesting differential reporting of BCG vaccine doses administered and/or BCG vaccine-related AEFI. The most commonly reported reactions were abscess (31%), injection site reaction (27%) and lymphadenopathy/lymphadenitis (17%). This study provides baseline data on BCG vaccine safety to inform surveillance. Given the current use of unregistered vaccines in the context of vaccine supply issues, improved recording of both administered BCG vaccine doses and the reporting of BCG vaccine-related AEFI are required to facilitate close monitoring of vaccine safety.

  16. High-dose buprenorphine: perioperative precautions and management strategies.

    PubMed

    Roberts, D M; Meyer-Witting, M

    2005-02-01

    Buprenorphine has been in clinical use in anaesthesia for several decades. Recently, the high-dose sublingual formulation (Subutex, Reckitt Benckiser, Slough, U.K.) has been increasingly used as maintenance therapy in opioid dependence, as an alternative to methadone and other pharmacological therapies. Buprenorphine has unique pharmacological properties making it well suited for use as a maintenance therapy in opioid dependence. However, these same properties may cause difficulty in the perioperative management of pain. Buprenorphine is a partial opioid agonist, attenuating the effects of supplemental illicit or therapeutic opioid agonists. As a result of its high receptor affinity, supplemental opioids do not readily displace buprenorphine from the opioid receptor in standard doses. High-dose buprenorphine has an extended duration of action that prolongs both of these effects. The perioperative management of patients stabilized on high-dose buprenorphine and undergoing surgery requires consideration of the likely analgesic requirements. Where possible the buprenorphine should be continued. Pain management should focus on maximizing non-opioid analgesia, local anaesthesia and non-pharmacological techniques. Where pain may not be adequately relieved by these methods, the addition of a full opioid agonist such as fentanyl or morphine at appropriate doses should be considered, accompanied by close monitoring in a high dependency unit. In situations where this regimen is unlikely to be effective, preoperative conversion to morphine or methadone may be an option. Where available, liaison with a hospital-based alcohol and drug service should always be considered.

  17. Cloud-Based CT Dose Monitoring using the DICOM-Structured Report: Fully Automated Analysis in Regard to National Diagnostic Reference Levels.

    PubMed

    Boos, J; Meineke, A; Rubbert, C; Heusch, P; Lanzman, R S; Aissa, J; Antoch, G; Kröpil, P

    2016-03-01

    To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDIvol) and dose length product (DLP). Data of 36,523 examinations (131,527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDIvol and DLP were 51.3% and 52.8% of the national DRLs, respectively. CTDIvol and DLP reached 43.8% and 43.1% for abdominal CT (n=10,590), 66.6% and 69.6% for cranial CT (n=16,098) and 37.8% and 44.0% for chest CT (n=10,387) of the compared national DRLs, respectively. Overall, the CTDIvol exceeded national DRLs in 1.9% of the examinations, while the DLP exceeded national DRLs in 2.9% of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50% of the DRLs. The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50% of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments. • The newly developed software based on the DICOM-Structured Report enables large-scale cloud-based CT dose monitoring • The implemented software solution enables automated benchmarking in regard to national DRLs • The local radiation exposure from CT reached approximately 50 % of the national DRLs • The cloud-based approach offers great potential for multi-center dose analysis. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Space dosimetry with the application of a 3D silicon detector telescope: response function and inverse algorithm.

    PubMed

    Pázmándi, Tamás; Deme, Sándor; Láng, Edit

    2006-01-01

    One of the many risks of long-duration space flights is the excessive exposure to cosmic radiation, which has great importance particularly during solar flares and higher sun activity. Monitoring of the cosmic radiation on board space vehicles is carried out on the basis of wide international co-operation. Since space radiation consists mainly of charged heavy particles (protons, alpha and heavier particles), the equivalent dose differs significantly from the absorbed dose. A radiation weighting factor (w(R)) is used to convert absorbed dose (Gy) to equivalent dose (Sv). w(R) is a function of the linear energy transfer of the radiation. Recently used equipment is suitable for measuring certain radiation field parameters changing in space and over time, so a combination of different measurements and calculations is required to characterise the radiation field in terms of dose equivalent. The objectives of this project are to develop and manufacture a three-axis silicon detector telescope, called Tritel, and to develop software for data evaluation of the measured energy deposition spectra. The device will be able to determine absorbed dose and dose equivalent of the space radiation.

  19. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.

    PubMed

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O'Connor, Una

    2015-09-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

  20. RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Maidment, Andrew D A; Kim, Woojin; Boonn, William W

    2011-01-01

    There is growing interest in the ability to monitor, track, and report exposure to radiation from medical imaging. Historically, however, dose information has been stored on an image-based dose sheet, an arrangement that precludes widespread indexing. Although scanner manufacturers are beginning to include dose-related parameters in the Digital Imaging and Communications in Medicine (DICOM) headers of imaging studies, there remains a vast repository of retrospective computed tomographic (CT) data with image-based dose sheets. Consequently, it is difficult for imaging centers to monitor their dose estimates or participate in the American College of Radiology (ACR) Dose Index Registry. An automated extraction software pipeline known as Radiation Dose Intelligent Analytics for CT Examinations (RADIANCE) has been designed that quickly and accurately parses CT dose sheets to extract and archive dose-related parameters. Optical character recognition of information in the dose sheet leads to creation of a text file, which along with the DICOM study header is parsed to extract dose-related data. The data are then stored in a relational database that can be queried for dose monitoring and report creation. RADIANCE allows efficient dose analysis of CT examinations and more effective education of technologists, radiologists, and referring physicians regarding patient exposure to radiation at CT. RADIANCE also allows compliance with the ACR's dose reporting guidelines and greater awareness of patient radiation dose, ultimately resulting in improved patient care and treatment.

  1. Active personal radiation monitor for lunar EVA

    NASA Astrophysics Data System (ADS)

    Straume, Tore; Borak, Tom; Braby, L. A.; Lusby, Terry; Semones, Edward J.; Vazquez, Marcelo E.

    As astronauts return to the Moon-and this time, work for extended periods-there will be a critical need for crew personnel radiation monitoring as they operate lunar rovers or otherwise perform a myriad of extravehicular activities (EVAs). Our focus is on development of a small personal radiation monitor for lunar EVA that responds to the complex radiation quality and changing dose rates on the Moon. Of particular concern are active monitoring capabilities that provide both early warning and radiation dosimetry information during solar particle events (SPEs). To accomplish this, we are developing small detectors integrated with modern high speed, low power microelectronics to measure dose-rate and dose-mean lineal energy in real time. The monitor is designed to perform over the range of dose rates and LETs expected from both GCR and SPE radiations during lunar EVA missions. The monitor design provides simultaneous measurement of dose-equivalent rates at two tissue-equivalent depths simulating skin and marrow. The compact personal monitor is estimated to be the size of a cell phone and would fit on an EVA spacesuit (e.g., in backpack) or in a toolbox. The four-year development effort (which began December 2007) will result in a prototype radiation monitor field tested and characterized for the major radiations expected on the surface of the Moon. We acknowledge support from NSBRI through grants to NASA Ames Research Center (T. Straume, PI) and Colorado State University (T. Borak, PI).

  2. Use of Magnetic Resonance Imaging to Monitor Iron Overload

    PubMed Central

    Wood, John C.

    2014-01-01

    SYNOPSIS Treatment of iron overload requires robust estimates of total body iron burden and its response to iron chelation therapy. Compliance with chelation therapy varies considerably among patients and individual reporting is notoriously unreliable. Even with perfect compliance, intersubject variability in chelator effectiveness is extremely high, necessitating reliable iron estimates to guide dose titration. In addition, each chelator has a unique profile with respect to clearing iron stores from different organs. This chapter will present the tools available to clinicians monitoring their patients, focusing on non-invasive magnetic resonance imaging methods because they have become the de-facto standard of care. PMID:25064711

  3. Clinical Decision Support Improves Initial Dosing and Monitoring of Tobramycin and Amikacin

    PubMed Central

    Cox, Zachary L.; Nelsen, Cori L.; Waitman, Lemuel R.; McCoy, Jacob A.; Peterson, Josh F.

    2010-01-01

    Purpose Clinical decision support (CDS) systems could be valuable tools in reducing aminoglycoside prescribing errors. We evaluated the impact of CDS on initial dosing, interval, and pharmacokinetic outcomes of amikacin and tobramycin therapy. Methods A complex CDS advisor to provide guidance on initial dosing and monitoring, using both traditional and extended interval dosing strategies, was integrated into computerized provider order entry (CPOE) and compared to a control group which featured close pharmacy monitoring of all aminoglycoside orders. A random sample of 118 patients from an academic, tertiary care medical center prescribed amikacin and tobramycin prior to advisor implementation was compared to 98 patients admitted following advisor implementation. Primary outcome was an initial dose within 10% of a dose calculated to be adherent to published dose guidelines. Secondary outcomes were a guideline-adherent interval, trough and peak concentrations in goal range, and incidence of nephrotoxicity. Results Of 216 patients studied, 97 were prescribed amikacin and 119 were prescribed tobramycin. The primary outcome of initial dosing consistent with guideline-based care increased from 40% in the pre-advisor arm to 80% in the post-advisor arm (p<0.001), with a number needed to treat of 3 patients to prevent one incorrect dose. Correct initial interval based on renal function also increased from 63% to 87% (p<0.001). The changes in initial dosing and interval resulted in an increase of trough concentrations in the goal range from 59% pre-advisor to 89% post-advisor implementation (p=0.0004). There was no significant difference in peak concentrations in goal range or incidence of nephrotoxicity (25% vs. 17%, p=0.2). Conclusion An advisor for aminoglycoside dosing and monitoring integrated into CPOE significantly improves initial dosing, selection of interval, and trough concentrations at goal compared to unassisted physician dosing. PMID:21411805

  4. Von Hippel-Lindau Disease (VHL)

    MedlinePlus

    ... tumors can be treated with focused high-dose irradiation. Individuals with VHL need careful monitoring by a ... tumors can be treated with focused high-dose irradiation. Individuals with VHL need careful monitoring by a ...

  5. Safety Profile during Initiation of Propranolol for Treatment of Infantile Hemangiomas in an Ambulatory Day-Care Hospitalization Setting.

    PubMed

    Fogel, Itay; Ollech, Ayelet; Zvulunov, Alex; Valdman-Greenshpon, Yulia; Atar-Sagie, Vered; Friedland, Rivka; Lapidoth, Moshe; Ben-Amitai, Dan

    2018-03-24

    Propranolol is the mainstay of treatment for infantile hemangioma. Despite its good safety profile, it is not risk-free. Guidelines for propranolol initiation and monitoring have been suggested, but protocols vary among practitioners. This study sought to assess the prevalence of adverse events and clinically significant fluctuations in hemodynamic parameters in children with infantile hemangioma during initiation of treatment with propranolol in a day-hospitalization setting. Children with infantile hemangioma treated with propranolol in a day-hospitalization department of a tertiary pediatric medical center in 2008-2014 were identified retrospectively. The pretreatment evaluation included clinical examination by a pediatric dermatologist and electrocardiography, echocardiography, and clinical examination by a pediatric cardiologist. The propranolol dosage was escalated from 0.5mg/kg/day to 2mg/kg/day, divided into 3 doses/day, over 3 days. Heart rate, blood pressure, and blood glucose level were measured before treatment onset and 60 min after the first two doses each day. The third dose was given at home. The cohort included 220 children aged 1 month to 5 years. No severe treatment-related adverse events were documented; 27 patients had minor side effects. There was a significant decrease in heart rate each day after the first two doses (p<0.001), and in systolic blood pressure, on day 2 (1mg/kg/day) after the first dose (p=0.01). Blood glucose level remained stable. The hemodynamic changes were clinically asymptomatic and did not require intervention. Propranolol treatment (2mg/kg/day in three doses) for infantile hemangioma is well tolerated and safe and may be administered and monitored in an ambulatory setting. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. What is the best approach to tailoring hydrocortisone dose to meet patient needs in 2012?

    PubMed

    Debono, Miguel; Ross, Richard J

    2013-05-01

    Cortisol is an essential stress hormone and replacement with oral hydrocortisone is lifesaving in patients with adrenal insufficiency. Cortisol has a diurnal rhythm regulated by the central body clock and this rhythm is a metabolic signal for peripheral tissue clocks. Loss of cortisol rhythmicity is associated with fatigue, depression and insulin resistance. A general principle in endocrinology is to replace hormones to replicate physiological concentrations; however, the pharmacokinetics of oral immediate-release hydrocortisone make it impossible to fully mimic the cortisol rhythm and patients still have an increased morbidity and mortality despite replacement. Traditionally, physicians have replaced hydrocortisone with a total daily dose based on the diurnal 24-h cortisol production rate with hydrocortisone given twice or thrice daily, with the highest dose first thing in the morning. Monitoring treatment and dose titration has been much debated with some clinicians using cortisol day curves and others relying on clinical symptoms. The main challenge is that there is no established biomarker of cortisol activity. In addressing the clinical question, we have taken the view that an understanding of the cortisol circadian rhythm and hydrocortisone pharmacokinetics is essential when tailoring hydrocortisone dose. Using this approach, we have developed a thrice daily, weight-related, dosing regimen and a pharmacokinetic and clinical method to monitor treatment. Our argument for replicating the cortisol circadian rhythm is based on the observation that disruption of the rhythm is associated with ill health, and the few studies that have compared different treatment regimens. Further studies are required to definitively test the benefits of replacing the cortisol circadian rhythm in patients with adrenal insufficiency. © 2012 Blackwell Publishing Ltd.

  7. Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors

    NASA Astrophysics Data System (ADS)

    Adamczyk, K.; Aihara, H.; Angelini, C.; Aziz, T.; Babu, V.; Bacher, S.; Bahinipati, S.; Barberio, E.; Baroncelli, T.; Basith, A. K.; Batignani, G.; Bauer, A.; Behera, P. K.; Bergauer, T.; Bettarini, S.; Bhuyan, B.; Bilka, T.; Bosi, F.; Bosisio, L.; Bozek, A.; Buchsteiner, F.; Casarosa, G.; Ceccanti, M.; Červenkov, D.; Chendvankar, S. R.; Dash, N.; Divekar, S. T.; Doležal, Z.; Dutta, D.; Forti, F.; Friedl, M.; Hara, K.; Higuchi, T.; Horiguchi, T.; Irmler, C.; Ishikawa, A.; Jeon, H. B.; Joo, C.; Kandra, J.; Kang, K. H.; Kato, E.; Kawasaki, T.; Kodyš, P.; Kohriki, T.; Koike, S.; Kolwalkar, M. M.; Kvasnička, P.; Lanceri, L.; Lettenbicher, J.; Mammini, P.; Mayekar, S. N.; Mohanty, G. B.; Mohanty, S.; Morii, T.; Nakamura, K. R.; Natkaniec, Z.; Negishi, K.; Nisar, N. K.; Onuki, Y.; Ostrowicz, W.; Paladino, A.; Paoloni, E.; Park, H.; Pilo, F.; Profeti, A.; Rashevskaya, I.; Rao, K. K.; Rizzo, G.; Rozanska, M.; Sandilya, S.; Sasaki, J.; Sato, N.; Schultschik, S.; Schwanda, C.; Seino, Y.; Shimizu, N.; Stypula, J.; Tanaka, S.; Tanida, K.; Taylor, G. N.; Thalmeier, R.; Thomas, R.; Tsuboyama, T.; Uozumi, S.; Urquijo, P.; Vitale, Lorenzo; Volpi, M.; Watanuki, S.; Watson, I. J.; Webb, J.; Wiechczynski, J.; Williams, S.; Würkner, B.; Yamamoto, H.; Yin, H.; Yoshinobu, T.

    2016-07-01

    The Belle-II VerteX Detector (VXD) has been designed to improve the performances with respect to Belle and to cope with an unprecedented luminosity of 8 ×1035cm-2s-1 achievable by the SuperKEKB. Special care is needed to monitor both the radiation dose accumulated throughout the life of the experiment and the instantaneous radiation rate, in order to be able to promptly react to sudden spikes for the purpose of protecting the detectors. A radiation monitoring and beam abort system based on single-crystal diamond sensors is now under an active development for the VXD. The sensors will be placed in several key positions in the vicinity of the interaction region. The severe space limitations require a challenging remote readout of the sensors.

  8. Bispectral Index Monitoring during Anesthesiologist-Directed Propofol and Remifentanil Sedation for Endoscopic Submucosal Dissection: A Prospective Randomized Controlled Trial

    PubMed Central

    Park, Woo Young; Shin, Yang-Sik; Lee, Sang Kil; Kim, So Yeon; Lee, Tai Kyung

    2014-01-01

    Purpose Endoscopic submucosal dissection (ESD) is a technically difficult and lengthy procedure requiring optimal depth of sedation. The bispectral index (BIS) monitor is a non-invasive tool that objectively evaluates the depth of sedation. The purpose of this prospective randomized controlled trial was to evaluate whether BIS guided sedation with propofol and remifentanil could reduce the number of patients requiring rescue propofol, and thus reduce the incidence of sedation- and/or procedure-related complications. Materials and Methods A total of 180 patients who underwent the ESD procedure for gastric adenoma or early gastric cancer were randomized to two groups. The control group (n=90) was monitored by the Modified Observer's Assessment of Alertness and Sedation scale and the BIS group (n=90) was monitored using BIS. The total doses of propofol and remifentanil, the need for rescue propofol, and the rates of complications were recorded. Results The number of patients who needed rescue propofol during the procedure was significantly higher in the control group than the BIS group (47.8% vs. 30.0%, p=0.014). There were no significant differences in the incidence of sedation- and/or procedure-related complications. Conclusion BIS-guided propofol infusion combined with remifentanil reduced the number of patients requiring rescue propofol in ESD procedures. However, this finding did not lead to clinical benefits and thus BIS monitoring is of limited use during anesthesiologist-directed sedation. PMID:25048506

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NSTec Environmental Restoration

    Homeland Security Presidential Directive HSPD-5 requires all federal departments and agencies to adopt a National Incident Management System (NIMS)/Incident Command System (ICS) and use it in their individual domestic incident management and emergency prevention, preparedness, response, recovery, and mitigation programs and activities, as well as in support of those actions taken to assist state and local entities. This system provides a consistent nationwide template to enable federal, state, local, and tribal governments, private-sector, and nongovernmental organizations to work together effectively and efficiently to prepare for, prevent, respond to, and recover from domestic incidents, regardless of cause, size, or complexity, includingmore » acts of catastrophic terrorism. This document identifies the operational concepts of the Federal Radiological Monitoring and Assessment Center's (FRMAC) implementation of the NIMS/ICS response structure under the National Response Plan (NRP). The construct identified here defines the basic response template to be tailored to the incident-specific response requirements. FRMAC's mission to facilitate interagency environmental data management, monitoring, sampling, analysis, and assessment and link this information to the planning and decision staff clearly places the FRMAC in the Planning Section. FRMAC is not a mitigating resource for radiological contamination but is present to conduct radiological impact assessment for public dose avoidance. Field monitoring is a fact-finding mission to support this effort directly. Decisions based on the assessed data will drive public protection and operational requirements. This organizational structure under NIMS is focused by the mission responsibilities and interface requirements following the premise to provide emergency responders with a flexible yet standardized structure for incident response activities. The coordination responsibilities outlined in the NRP are based on the NIMS/ICS construct and Unified Command (UC) for management of a domestic incident. The NRP Nuclear/Radiological Incident Annex (NUC) further provides requirements and protocols for coordinating federal government capabilities to respond to nuclear/radiological Incidents of National Significance (INS) and other radiological incidents. When a FRMAC is established, it operates under the parameters of NIMS as defined in the NRP. FRMAC and its operations have been modified to reflect NIMS/ICS concepts and principles and to facilitate working in a Unified Command structure. FRMAC is established at or near the scene of the incident to coordinate radiological monitoring and assessment and is established in coordination with the U.S. Department of Homeland Security (DHS); the coordinating agency; other federal agencies; and state, local, and tribal authorities. However, regardless of the coordinating agency designation, U.S. Department of Energy (DOE) coordinates radiological monitoring and assessment activities for the initial phases of the offsite federal incident response through the Radiological Assistance Program (RAP) and FRMAC assets. Monitoring and assessment data are managed by FRMAC in an accountable, secure, and retrievable format. Monitoring data interpretations, including exposure rate contours, dose projections, and any requested radiological assessments are to be provided to the DHS; to the coordinating agency; and to state, local, and tribal government agencies.« less

  10. 2009 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2010-04-14

    During the 2009 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2009, there were 159 person-trips that required dose monitoring of the U.S. monitors. Of the 159 person-trips, 149 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 4 monitoring visits by TMO monitors to facilities other than UEIE and 10 to UEIE itself. LLNL's Hazard Control Departmentmore » laboratories provided the dosimetry services for the HEU Transparency monitors. In 2009, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency Program now has over fifteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less

  11. Real-time colour pictorial radiation monitoring during coronary angiography: effect on patient peak skin and total dose during coronary angiography.

    PubMed

    Wilson, Sharon M; Prasan, Ananth M; Virdi, Amy; Lassere, Marissa; Ison, Glenn; Ramsay, David R; Weaver, James C

    2016-10-10

    The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.

  12. Processing speed can monitor stimulant-medication effects in adults with attention deficit disorder with hyperactivity.

    PubMed

    Nielsen, Niels Peter; Wiig, Elisabeth H; Bäck, Svante; Gustafsson, Jan

    2017-05-01

    Treatment responses to methylphenidate by adults with ADHD are generally monitored against DSM-IV/DSM-V symptomatology, rating scales or interviews during reviews. To evaluate the use of single- and dual-dimension processing-speed and efficiency measures to monitor the effects of pharmacological treatment with methylphenidate after a short period off medication. A Quick Test of Cognitive Speed (AQT) monitored the effects of immediate-release methylphenidate in 40 previously diagnosed and medicated adults with ADHD. Processing speed was evaluated with prior prescription medication, without medication after a 2-day period off ADHD medication, and with low-dose (10/20 mg) and high-dose (20/40 mg) methylphenidate hydrochloride (Medikinet IR). Thirty-three participants responded to the experimental treatments. One-way ANOVA with post-hoc analysis (Scheffe) indicated significant main effects for single dimension colour and form and dual-dimension colour-form naming. Post-hoc analysis indicated statistical differences between the no- and high-dose medication conditions for colour and form, measures of perceptual speed. For colour-form naming, a measure of cognitive speed, there was a significant difference between no- and low-dose medication and between no- and high-dose medications, but not between low- and high-dose medications. Results indicated that the AQT tests effectively monitored incremental effects of the methylphenidate dose on processing speed after a 2-day period off medication. Thus, perceptual (colour and form) and cognitive speed (two-dimensional colour-form naming) and processing efficiency (lowered shift costs) increased measurably with high-dose medication. These preliminary findings warrant validation with added measures of associated behavioural and cognitive changes.

  13. Serial Monitoring of Immune Markers Being Represented Regulatory T Cell/T Helper 17 Cell Ratio: Indicating Tolerance for Tapering Immunosuppression after Liver Transplantation

    PubMed Central

    Jhun, JooYeon; Lee, Seung Hoon; Lee, Soon Kyu; Kim, Hee Yeon; Jung, Eun Sun; Kim, Dong Goo; Choi, JeongWon; Bae, Si Hyun; Yoon, Seung Kew; Chung, Byung Ha; Yang, Chul Woo; Cho, Mi-La; Choi, Jong Young

    2018-01-01

    Recipients of liver transplantation (LT) require long-term immunosuppressive drug treatment, but lifelong immunosuppressive treatment has severe side effects. It is known that some LT recipients develop immune tolerance, and although the development of such operational tolerance should allow a decrease in the burden of immunosuppressive drug treatment, the factors that indicate operational tolerance are not clear. This study aimed to monitor immunological markers over time in LT recipients to identify those markers indicating the development of operational tolerance. We performed a prospective pilot study measuring immune markers, including the ratio of regulatory T (Treg) and T helper (Th) 17 cells in peripheral blood in the 14 most immunologically stable patients among 70 clinically stable LT recipients. The doses of immunosuppressive drugs given to these 14 LT recipients were tapered over time and they were monitored for immunological markers related to the development of immune tolerance. As the doses of immunosuppressive drugs were reduced, the Treg/Th17, Th1/Th17, and CD8/Th17 ratio in tolerant recipients was significantly increased compared with that of nontolerant recipients. These results suggest that monitoring of changes in the immune makers, including Treg/Th17 ratio during tapering of immunosuppression may allow prediction of the development of tolerance. PMID:29545795

  14. [Dosimetric system for assessing doses received by people occupationally exposed to external sources of ionizing radiation].

    PubMed

    Brodecki, Marcin; Domienik, Joanna U; Zmyślony, Marek

    2012-01-01

    The current system of dosimetric quantities has been defined by the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU). Complexity of the system implies the physical nature of ionizing radiation, resulting from the presence of different types of radiation of different ionization capabilities, as well as the individual radiation sensitivity of biological material exposed. According to the latest recommendations, there are three types of dosimeter quantities relevant to radiation protection and radiological assessment of occupational exposure. These are the basic quantities, safety quantities and operational quantities. Dose limits for occupational exposure relate directly to the protection quantities, i.e. the equivalent dose and effective dose, while these quantities are practically unmeasurable in real measurement conditions. For this reason, in the system of dosimetric quantities directly measurable operating volumes were defined. They represent equivalents of the protection quantities that allow for a reliable assessment of equivalent and effective dose by conducting routine monitoring of occupational exposure. This paper presents the characteristics of these quantities, their relationships and importance in assessing individual effects of radiation. Also the methods for their implementation in personal and environmental dosimetry were showcased. The material contained in the article is a compendium of essential information about dosimetric quantities with reference to the contemporary requirements of the law, including the changed annual occupational exposure limit for the lens of the eye. The material is especially addressed to those responsible for dosimetry monitoring in the workplace, radiation protection inspectors and occupational health physicians.

  15. Is eye lens dosimetry needed in nuclear medicine?

    PubMed

    Wrzesień, M; Królicki, L; Albiniak, Ł; Olszewski, J

    2018-06-01

    The exact level of exposure experienced by nuclear medicine personnel, whose work often requires performing manual procedures involving radioactive isotopes, is associated with the form of radiation source used. The variety of radionuclides and medical procedures, and the yearly increase in the number of patients, as well as the change of the individual dose limit for the lens of the eye from a value of 150 mSv yr -1 to 20 mSv yr -1 , mean that issues of eye lens routine dosimetry become interesting from the radiation protection point of view. This paper presents an analysis of the exposure of the eye lenses of nuclear medicine department personnel, as well as those of personnel in the facilities that produce radiopharmaceuticals for the purpose of diagnosis by positron emission tomography, from the viewpoint of the advisability of routine eye lens exposure monitoring, taking into account changes in the dose limit for the lens of the eye. The paper considers the two most commonly used radionuclides for diagnostic purposes 99m Tc, 18 F, and-for therapeutic purposes- 131 I. Dose measurements were made using thermoluminescent detectors. The estimated exposure analysis identifies the cases when the maximum annual value of the personal dose equivalent, in terms of Hp(3), exceeds threefold the new limit value (20 mSv yr -1 ). It is recommended that Hp(3) doses be routinely monitored in the group of radiopharmacists who label pharmaceuticals with the radionuclide 99m Tc and in chemists working in 18 F-FDG quality control departments in production units, where this is carried out manually.

  16. Comparative effects of vildagliptin and sitagliptin determined by continuous glucose monitoring in patients with type 2 diabetes mellitus.

    PubMed

    Koyanagawa, Naohide; Miyoshi, Hideaki; Ono, Kota; Nakamura, Akinobu; Cho, Kyu Yong; Yamamoto, Kohei; Takano, Yoshinari; Dan-Noura, Midori; Atsumi, Tatsuya

    2016-08-31

    The dipeptidyl peptidase-4 inhibitors vildagliptin and sitagliptin are effective in treating patients with type 2 diabetes mellitus. Patients receiving standard doses of sitagliptin plus insulin may require increased doses of sitagliptin or switching to vildagliptin to improve blood glucose control. This study compared the effects of increasing sitagliptin and switching to vildagliptin in type 2 diabetes patients receiving standard doses of sitagliptin plus insulin. This prospective, randomized, parallel-group comparison trial enrolled 33 type 2 diabetes patients receiving 50 mg sitagliptin once daily plus insulin. Seventeen patients were randomized to 50 mg vildagliptin twice daily, and 16 to 100 mg sitagliptin once daily, and evaluated by continuous glucose monitoring at baseline and after 8 weeks. The primary end-point was the change in mean amplitude of glycemic excursions (MAGE). MAGE decreased from baseline in both the vildagliptin (-13.4 ± 35.7 mg/dL) and sitagliptin (-8.4 ± 24.3 mg/dL) groups, but neither within- nor between-group changes were statistically significant. Similarly, the areas under the curve for blood glucose levels ≥180 mg/dL and <70 mg/dL tended to improve in both groups, but these differences were not statistically significant. In contrast, HbA1c was significantly reduced only in the vildagliptin group, from 7.1 ± 0.6% at baseline to 6.8 ± 0.6% at 8 weeks (p=0.006). Increasing sitagliptin dose and switching to vildagliptin had limited effects in improving MAGE in type 2 diabetic patients treated with standard doses of sitagliptin.

  17. A Multicenter, Randomized, Open-Label, Pharmacokinetics and Safety Study of Pantoprazole Tablets in Children and Adolescents Aged 6 Through 16 Years With GERD

    PubMed Central

    Ward, Robert M.; Kearns, Gregory L.; Tammara, Brinda; Bishop, Phyllis; O’Gorman, Molly A.; James, Laura P.; Katz, Mitchell H.; Maguire, Mary K.; Rath, Natalie; Meng, Xu; Comer, Gail M.

    2011-01-01

    SUMMARY Children with GERD may benefit from gastric acid suppression with proton pump inhibitors such as pantoprazole. Effective treatment with pantoprazole requires correct dosing and understanding of the drug’s kinetic profile in children. The aim of these studies was to characterize the pharmacokinetic (PK) profile of single and multiple doses of pantoprazole delayed-release tablets in pediatric patients with GERD aged ≥6 through 11 years (study 1) and 12 through 16 years (study 2). Patients were randomly assigned to receive pantoprazole 20 or 40 mg once daily. Plasma pantoprazole concentrations were obtained at intervals through 12 hours after the single dose, and at 2 and 4 hours after multiple doses for PK evaluation. PK parameters were derived by standard noncompartmental methods and examined as a function of both drug dose and patient age. Safety was also monitored. Pantoprazole PK was dose independent (when dose normalized) and similar toPK reported from adult studies. There was no evidence of accumulation with multiple dosing or reports of serious drug-associated adverse events. In children aged 6 to 16 years with GERD, currently available pantoprazole delayed-release tablets can be used to provide systemic exposure similar to that in adults. PMID:20852004

  18. Medications during pregnancy: antihypertensives and immunosuppressives.

    PubMed

    Umans, Jason G

    2007-04-01

    Use of prescription and nonprescription medications is common during pregnancy and is required in many women with underlying kidney disease or hypertension and in all with solid-organ allografts. Systematic assessment of drug safety during pregnancy is lacking, as are rigorous and comprehensive studies of pharmacokinetics and pharmacodynamics to guide drug selection and dosing across pregnancy. Renal and hepatic clearances of many drugs change markedly during pregnancy and pitfalls may complicate routine therapeutic monitoring of some drugs during pregnancy. However, available data and clinical experience allow reasonable strategies for selection and dosing of immunosuppressive agents in pregnant transplant recipients and of antihypertensive agents in women with mild or more severe hypertension complicating their pregnancies.

  19. Characterization of Photofrin photobleaching for singlet oxygen dose estimation during photodynamic therapy of MLL cells in vitro

    NASA Astrophysics Data System (ADS)

    Dysart, Jonathan S.; Patterson, Michael S.

    2005-06-01

    A singlet oxygen dose model is developed for PDT with Photofrin. The model is based on photosensitizer photobleaching kinetics, and incorporates both singlet oxygen and non-singlet oxygen mediated bleaching mechanisms. To test our model, in vitro experiments were performed in which MatLyLu (MLL) cells were incubated in Photofrin and then irradiated with 532 nm light. Photofrin fluorescence was monitored during treatment and, at selected fluence levels, cell viability was determined using a colony formation assay. Cell survival correlated well to calculated singlet oxygen dose, independent of initial Photofrin concentration or oxygenation. About 2 × 108 molecules of singlet oxygen per cell were required to reduce the surviving fraction by 1/e. Analysis of the photobleaching kinetics suggests that the lifetime of singlet oxygen in cells is 0.048 ± 0.005 µs. The generation of fluorescent photoproducts was not a result of singlet oxygen reactions exclusively, and therefore did not yield additional information to aid in quantifying singlet oxygen dose.

  20. SPIRIT: A seamless phase I/II randomized design for immunotherapy trials.

    PubMed

    Guo, Beibei; Li, Daniel; Yuan, Ying

    2018-06-07

    Immunotherapy-treatments that enlist the immune system to battle tumors-has received widespread attention in cancer research. Due to its unique features and mechanisms for treating cancer, immunotherapy requires novel clinical trial designs. We propose a Bayesian seamless phase I/II randomized design for immunotherapy trials (SPIRIT) to find the optimal biological dose (OBD) defined in terms of the restricted mean survival time. We jointly model progression-free survival and the immune response. Progression-free survival is used as the primary endpoint to determine the OBD, and the immune response is used as an ancillary endpoint to quickly screen out futile doses. Toxicity is monitored throughout the trial. The design consists of two seamlessly connected stages. The first stage identifies a set of safe doses. The second stage adaptively randomizes patients to the safe doses identified and uses their progression-free survival and immune response to find the OBD. The simulation study shows that the SPIRIT has desirable operating characteristics and outperforms the conventional design. Copyright © 2018 John Wiley & Sons, Ltd.

  1. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.

    PubMed

    Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven

    2015-05-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E).

  2. Analytical interference in the therapeutic drug monitoring of methotrexate.

    PubMed

    Oudart, Jean-Baptiste; Marquet, Benjamin; Feliu, Catherine; Gozalo, Claire; Djerada, Zoubir; Millart, Hervé

    2016-06-01

    High-dose of methotrexate chemotherapy is used in the treatment of some tumors. It presents several side effects that required therapeutic drug monitoring, which is commonly performed on 24, 48 and 72h after the beginning of the methotrexate infusion. Treatment of overexposure to methotrexate is based on injection of carboxypeptidase G2, which specifically degrades methotrexate into inactive metabolite: DAMPA. FPIA immunoassay on TDx automated analyzer (Abbott™) was used for therapeutic drug monitoring of methotrexate. This immunoassay presented a significant cross-reactivity between methotrexate and DAMPA, which widely overestimate the residual concentration compared to the gold standard HPLC/MS. TDx automated analyzer was substituted by a new immunoassay on Architect automated analyzer (Abbott™). However, this immunoassay has the same cross-reactivity, which needs to be careful when monitoring methotrexate after an injection of carboxypeptidase G2. In order to determine the most suitable assay for the therapeutic drug monitoring of methotrexate, the knowledge of injection of carboxypeptidase G2 remains essential.

  3. Niagara Falls Storage Site environmental report for calendar year 1992, 1397 Pletcher Road, Lewiston, New York. Formerly Utilized Sites Remedial Action Program (FUSRAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-05-01

    This report describes the environmental surveillance program at the Niagara Falls Storage Site (NFSS) and provides the results for 1992. From 1944 to the present, the primary use of NFSS has been storage of radioactive residues produced as a by-product of uranium production. All onsite areas of residual radioactivity above guidelines have been remediated. Materials generated during remediation are stored onsite in the 4-ha (10-acre) waste containment structure (WCS). The WCS is a clay-lined, clay-capped, and grass-covered storage pile. The environmental surveillance program at NFSS includes sampling networks for radon concentrations in air; external gamma radiation exposure; and total uraniummore » and radium-226 concentrations in surface water, sediments, and groundwater. Several chemical parameters, including seven metals, are also routinely measured in groundwater. This surveillance program assists in fulfilling the DOE policy of measuring and monitoring effluents from DOE activities and calculating hypothetical doses. Monitoring results are compared with applicable Environmental Protection Agency (EPA) and New York State Department of Environmental Conservation (NYSDEC) standards, DOE derived concentration guides (DCGs), dose limits, and other DOE requirements. Results of environmental monitoring during 1992 indicate that levels of the parameters measured were in compliance with all but one requirement: Concentrations of iron and manganese in groundwater were above NYSDEC groundwater quality standards. However, these elements occur naturally in the soils and groundwater associated with this region. In 1992 there were no environmental occurrences or reportable quantity releases.« less

  4. A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) Detector.

    PubMed

    Ji, Young-Yong; Kim, Chang-Jong; Lim, Kyo-Sun; Lee, Wanno; Chang, Hyon-Sock; Chung, Kun Ho

    2017-10-01

    To expand the application of dose rate spectroscopy to the environment, the method using an environmental radiation monitor (ERM) based on a 3' × 3' NaI(Tl) detector was used to perform real-time monitoring of the dose rate and radioactivity for detected gamma nuclides in the ground around an ERM. Full-energy absorption peaks in the energy spectrum for dose rate were first identified to calculate the individual dose rates of Bi, Ac, Tl, and K distributed in the ground through interference correction because of the finite energy resolution of the NaI(Tl) detector used in an ERM. The radioactivity of the four natural radionuclides was then calculated from the in situ calibration factor-that is, the dose rate per unit curie-of the used ERM for the geometry of the ground in infinite half-space, which was theoretically estimated by Monte Carlo simulation. By an intercomparison using a portable HPGe and samples taken from the ground around an ERM, this method to calculate the dose rate and radioactivity of four nuclides using an ERM was experimentally verified and finally applied to remotely monitor them in real-time in the area in which the ERM had been installed.

  5. Rocky Flats Plant Site Environmental Report for 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cirrincione, D.A.; Erdmann, N.L.

    1992-12-31

    The Rocky Rats Plant Site Environmental Report provides summary information on the plant`s environmental monitoring programs and the results recorded during 1992. The report contains a compliance summary, results of environmental monitoring and other related programs, a review of environmental remediation activities, information on external gamma radiation dose monitoring, and radiation dose estimates for the surrounding population.

  6. Comparing paediatric intravenous phenytoin doses using physiologically based pharmacokinetic (PBPK) modelling software.

    PubMed

    Batchelor, Hannah; Appleton, Richard; Hawcutt, Daniel B

    2015-12-01

    To use a physiologically based pharmacokinetic (PBPK) modelling system to predict the serum levels achieved by two different intravenous loading doses of phenytoin. A phenytoin pharmacokinetic model was used in the Simcyp population-based ADME simulator, simulating 100 children age 2-10 years receiving intravenous phenytoin (18 and 20mg/kg). Visual checks were used to evaluate the predictive performance of the candidate model. Loading with doses of 18 mg/kg, blood levels were sub-therapeutic in 22/100 (concentration at 2h post infusion (C2h) <10 μg/mL), therapeutic in 62/100 (C2h 10-20 μg/mL), and supra-therapeutic in 16/100 (C2h>20 μg/mL). Loading with 20mg/kg, the percentages were 15, 59, and 26, respectively. Increasing from 18 to 20 mg/kg increased the mean C2h from 16.0 to 17.9 μg/mL, and the mean AUC from 145 to 162 μg/mL/h. A C2h>30 μg/mL was predicted in 4% and 8% of children in the 18 and 20 mg/kg doses, with 3% predicted to have a C2h>40 μg/mL following either dose. For maintenance doses, a 1st dose of 2.5 or 5mg/kg (intravenous) given at 12h (after either 18 or 20 mg/kg loading) gives the highest percentages of 10-20 μg/mL serum concentrations. For sub-therapeutic concentrations following intravenous loading (20 mg/kg), a 1st maintenance dose (intravenous) of 10mg/kg will achieve therapeutic concentrations in 93%. Use of PBPK modelling suggests that children receiving the 20 mg/kg intravenous loading dose are at slightly increased risk of supra-therapeutic blood levels. Ideally, therapeutic drug monitoring is required to monitor serum concentrations, although the dose regime suggested by the BNFc appear appropriate. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  7. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    PubMed

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  8. Small Active Radiation Monitor

    NASA Technical Reports Server (NTRS)

    Badhwar, Gautam D.

    2004-01-01

    A device, named small active radiation monitor, allows on-orbit evaluations during periods of increased radiation, after extravehicular activities, or at predesignated times for crews on such long-duration space missions as on the International Space Station. It also permits direct evaluation of biological doses, a task now performed using a combination of measurements and potentially inaccurate simulations. Indeed the new monitor can measure a full array of radiation levels, from soft x-rays to hard galactic cosmic-ray particles. With refinement, it will benefit commercial (nuclear power-plant workers, airline pilots, medical technicians, physicians/dentists, and others) and military personnel as well as the astronauts for whom thermoluminescent dosimeters are inadequate. Civilian and military personnel have long since graduated from film badges to thermoluminescent dosimeters. Once used, most dosimeters must be returned to a central facility for processing, a step that can take days or even weeks. While this suffices for radiation workers for whom exposure levels are typically very low and of brief duration, it does not work for astronauts. Even in emergencies and using express mail, the results can often be delayed by as much as 24 hours. Electronic dosimeters, which are the size of electronic oral thermometers, and tattlers, small electronic dosimeters that sound an alarm when the dose/dose rate exceeds preset values, are also used but suffer disadvantages similar to those of thermoluminescent dosimeters. None of these devices fully answers the need of rapid monitoring during the space missions. Instead, radiation is monitored by passive detectors, which are read out after the missions. Unfortunately, these detectors measure only the absorbed dose and not the biologically relevant dose equivalent. The new monitor provides a real-time readout, a time history of radiation exposures (both absorbed dose and biologically relevant dose equivalent), and a count of the number of particles passing through a unit area. Better still, the monitor can be used anywhere.

  9. Novel spectrometers for environmental dose rate monitoring.

    PubMed

    Kessler, P; Behnke, B; Dabrowski, R; Dombrowski, H; Röttger, A; Neumaier, S

    2018-07-01

    A new generation of dosemeters, based on the scintillators LaBr 3 , CeBr 3 and SrI 2 , read out with conventional photomultipliers, to be used in the field of environmental gamma-radiation monitoring, was investigated. The main features of these new instruments and especially their outdoor performance, studied by long-term investigations under real weather conditions, are presented. The systems were tested at the reference sites for environmental radiation of the Physikalisch-Technische Bundesanstalt. The measurements are compared with that of well characterized classical dose rate reference instruments to demonstrate the suitability of new spectrometers for environmental dose rate monitoring even in adverse weather conditions. Their potential to replace the (mainly Geiger Müller based) dose rate meters operated in about 5000 European early waning network stations as well as in environmental radiation monitoring in general is shown. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Role of Pharmacogenomics in the Management of Traditional and Novel Oral Anticoagulants

    PubMed Central

    Cavallari, Larisa H.; Shin, Jaekyu; Perera, Minoli A.

    2013-01-01

    Warfarin is the most commonly prescribed oral anticoagulant. However, it remains a difficult drug to manage mostly because of its narrow therapeutic index and wide interpatient variability in anticoagulant effects. Over the past decade, there has been substantial progress in our understanding of genetic contributions to variable warfarin response, particularly with regard to warfarin dose requirements. The genes encoding for cytochrome P450 (CYP) 2C9 (CYP2C9) and vitamin K epoxide reductase complex subunit 1 (VKORC1) are the major genetic determinants of warfarin pharmacokinetics and pharmacodynamics, respectively. Numerous studies have demonstrated significant contributions of these genes to warfarin dose requirements. The CYP2C9 gene has also been associated with bleeding risk with warfarin. The CYP4F2 gene influences vitamin K availability and makes minor contributions to warfarin dose requirements. Less is known about genes influencing warfarin response in African-American patients compared with other racial groups, but this is the focus of ongoing research. Several warfarin pharmacogenetic dosing algorithms and United States Food and Drug Administration–cleared genotyping tests are available for clinical use. Clinical trials are ongoing to determine the clinical utility and cost-effectiveness of genotype-guided warfarin dosing. Results from these trials will likely influence clinical uptake and third party payer reimbursement for genotype-guided warfarin therapy. There is still a lack of pharmacogenetic data for the newly approved oral anticoagulants, dabigatran and rivaroxaban, and with other oral anticoagulants in the research and development pipeline. These data, once known, could be of great importance as routine monitoring parameters for these agents are not available. PMID:22122181

  11. FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS.

    PubMed

    Clairand, I; Ginjaume, M; Vanhavere, F; Carinou, E; Daures, J; Denoziere, M; Silva, E H; Roig, M; Principi, S; Van Rycheghem, L

    2016-09-01

    In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. 2004 Environmental Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Althouse, P E; Bertoldo, N A; Brown, R A

    2005-09-28

    The Lawrence Livermore National Laboratory (LLNL) annual Environmental Report, prepared for the Department of Energy (DOE) and made available to the public, presents summary environmental data that characterizes site environmental management performance, summarizes environmental occurrences and responses reported during the calendar year, confirms compliance with environmental standards and requirements, and highlights significant programs and efforts. By explaining the results of effluent and environmental monitoring, mentioning environmental performance indicators and performance measure programs, and assessing the impact of Laboratory operations on the environment and the public, the report also demonstrates LLNL's continuing commitment to minimize any potentially adverse impact of itsmore » operations. The combination of environmental and effluent monitoring, source characterization, and dose assessment showed that radiological doses to the public caused by LLNL operations in 2004 were less than 0.26% of regulatory standards and more than 11,000 times smaller than dose from natural background. Analytical results and evaluations generally showed continuing low levels of most contaminants; remediation efforts further reduced the concentrations of contaminants of concern in groundwater and soil vapor. In addition, LLNL's extensive environmental compliance activities related to water, air, endangered species, waste, wastewater, and waste reduction controlled or reduced LLNL's effects on the environment. LLNL's environmental program clearly demonstrates a commitment to protecting the environment from operational impacts.« less

  13. Design optimisation of a TOF-based collimated camera prototype for online hadrontherapy monitoring

    NASA Astrophysics Data System (ADS)

    Pinto, M.; Dauvergne, D.; Freud, N.; Krimmer, J.; Letang, J. M.; Ray, C.; Roellinghoff, F.; Testa, E.

    2014-12-01

    Hadrontherapy is an innovative radiation therapy modality for which one of the main key advantages is the target conformality allowed by the physical properties of ion species. However, in order to maximise the exploitation of its potentialities, online monitoring is required in order to assert the treatment quality, namely monitoring devices relying on the detection of secondary radiations. Herein is presented a method based on Monte Carlo simulations to optimise a multi-slit collimated camera employing time-of-flight selection of prompt-gamma rays to be used in a clinical scenario. In addition, an analytical tool is developed based on the Monte Carlo data to predict the expected precision for a given geometrical configuration. Such a method follows the clinical workflow requirements to simultaneously have a solution that is relatively accurate and fast. Two different camera designs are proposed, considering different endpoints based on the trade-off between camera detection efficiency and spatial resolution to be used in a proton therapy treatment with active dose delivery and assuming a homogeneous target.

  14. Evaluation of the brain anaesthesia response monitor during anaesthesia for cardiac surgery: a double-blind, randomised controlled trial using two doses of fentanyl.

    PubMed

    Shoushtarian, Mehrnaz; McGlade, Desmond P; Delacretaz, Louis J; Liley, David T J

    2016-12-01

    The brain anaesthesia response (BAR) monitor uses a method of EEG analysis, based on a model of brain electrical activity, to monitor the cerebral response to anaesthetic and sedative agents via two indices, composite cortical state (CCS) and cortical input (CI). It was hypothesised that CCS would respond to the hypnotic component of anaesthesia and CI would differentiate between two groups of patients receiving different doses of fentanyl. Twenty-five patients scheduled to undergo elective first-time coronary artery bypass graft surgery were randomised to receive a total fentanyl dose of either 12 μg/kg (fentanyl low dose, FLD) or 24 μg/kg (fentanyl moderate dose, FMD), both administered in two divided doses. Propofol was used for anaesthesia induction and pancuronium for intraoperative paralysis. Hemodynamic management was protocolised using vasoactive drugs. BIS, CCS and CI were simultaneously recorded. Response of the indices (CI, CCS and BIS) to propofol and their differences between the two groups at specific points from anaesthesia induction through to aortic cannulation were investigated. Following propofol induction, CCS and BIS but not CI showed a significant reduction. Following the first dose of fentanyl, CI, CCS and BIS decreased in both groups. Following the second dose of fentanyl, there was a significant reduction in CI in the FLD group but not the FMD group, with no significant change found for BIS or CCS in either group. The BAR monitor demonstrates the potential to monitor the level of hypnosis following anaesthesia induction with propofol via the CCS index and to facilitate the titration of fentanyl as a component of balanced anaesthesia via the CI index.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    The Office of Analysis within the U.S. Department of Energy (DOE) Office of Environment, Health, Safety and Security (EHSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2013 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies formore » protection of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past five-year period, the occupational radiation exposure information has been analyzed in terms of aggregate data, dose to individuals, and dose by site.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2012 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protectionmore » of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past 5-year period, the occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site.« less

  17. Safety and Immune Responses in Children After Concurrent or Sequential 2009 H1N1 and 2009–2010 Seasonal Trivalent Influenza Vaccinations

    PubMed Central

    Frey, Sharon E.; Bernstein, David I.; Gerber, Michael A.; Keyserling, Harry L.; Munoz, Flor M.; Winokur, Patricia L.; Turley, Christine B.; Rupp, Richard E.; Hill, Heather; Wolff, Mark; Noah, Diana L.; Ross, Allison C.; Cress, Gretchen; Belshe, Robert B.

    2012-01-01

    Background. Administering 2 separate vaccines for seasonal and pandemic influenza was necessary in 2009. Therefore, we conducted a randomized trial of monovalent 2009 H1N1 influenza vaccine (2009 H1N1 vaccine) and seasonal trivalent inactivated influenza vaccine (TIV; split virion) given sequentially or concurrently in previously vaccinated children. Methods. Children randomized to 4 study groups and stratified by age received 1 dose of seasonal TIV and 2 doses of 2009 H1N1 vaccine in 1 of 4 combinations. Injections were given at 21-day intervals and serum samples for hemagglutination inhibition antibody responses were obtained prior to and 21 days after each vaccination. Reactogenicity and adverse events were monitored. Results. All combinations of vaccines were safe in the 531 children enrolled. Generally, 1 dose of 2009 H1N1 vaccine and 1 dose of TIV, regardless of sequence or concurrency of administration, was immunogenic in children ≥10 years of age; children <10 years of age required 2 doses of 2009 H1N1 vaccine. Conclusions. Vaccines were generally well tolerated. The immune responses to 2009 H1N1 vaccine were adequate regardless of the sequence of vaccination in all age groups but the sequence affected titers to TIV antigens. Two doses of 2009 H1N1 vaccine were required to achieve a protective immune response in children <10 years of age. Clinical Trials Registration. NCT00943202. PMID:22802432

  18. Space weather effects and commerical airlines

    NASA Astrophysics Data System (ADS)

    Jones, J.; Bentley, R.; Hunter, R.; Taylor, G.; Thomas, D.

    Space Weather (SW) phenomena can effect many areas of commercial airline operations including avionics, communications and GPS navigation systems. Of particular importance at present is the recently introduced EU legislation requiring the monitoring of aircrew radiation exposure, including any variations at aircraft altitudes due to solar activity. The Mullard Space Science Laboratory is collaborating with Virgin Atlantic Airways, the Civil Aviation Authority and the National Physical Laboratory on a 3- year project to monitor the levels of cosmic radiation on long-haul flights. The study will determine whether computer models currently used to predict radiation exposure of aircrew are adequate. It also aims to determine whether solar or geomagnetic activity can cause significant modifications to the doses. This presentation will begin by showing some of the preliminary results obtained so far. As an example, we present a comparison of flight doses measured following the 14t h July 2000 X - class flare that was accompanied by a major Solar Particle Event (SPE). The results highlight the importance of a range of external factors that can strongly influence how SPEs may effect the measured dose at aircraft altitudes. At present, any SPE contributions in the airlines' dose records can only be poorly estimated retrospectively. Ideally, it would be better to try to avoid operating during these possibly significant radiation - enhancing events by utilising SW information (alerts, warnings, etc.). However, doing so poses many difficult operational problems for such a heavily regulated international industry, in terms of safety, security and procedures. Therefore, the use of timely SW information, which is still very unreliable, in a similar manner to terrestrial weather will require agreement from the International Civil Aviation Organisation (ICAO) and International Air Transport Association (IATA) to Air Traffic Control and Aviation Regulatory Authority's. This presentation will, therefore, conclude by summarising some of the identified key issues, which must be addressed, with the help of the science community, if the airlines want to benefit from the availability of Space Weather Services.

  19. A comprehensive dosimetric evaluation of using RapidArc volumetric‐modulated arc therapy for the treatment of early‐stage nasopharyngeal carcinoma

    PubMed Central

    Wong, Wicger; Leung, Lucullus H.T.; Yu, Peter K.N.; So, Ronald W.K.; Cheng, Ashley C.K.

    2012-01-01

    The purpose of this study was to investigate the potential benefits of using triple‐arc volumetric‐intensity modulated arc radiotherapy (RapidArc (RA)) for the treatment of early‐stage nasopharyngeal carcinoma (NPC). A comprehensive evaluation was performed including plan quality, integral doses, and peripheral doses. Twenty cases of stage I or II NPC were selected for this study. Nine‐field sliding window IMRT, double‐arc, and triple‐arc RA treatment plans were compared with respect to target coverage, dose conformity, critical organ sparing, and integral doses. Measurement of peripheral doses was performed using thermoluminescent dosimeters in an anthropomorphic phantom. While similar conformity and target coverage were achieved by the three types of plans, triple‐arc RA produced better sparing of parotid glands and spinal cord than double‐arc RA or IMRT. Double‐arc RA plans produced slightly inferior parotid sparing and dose homogeneity than the other two delivery methods. The monitor units (MU) required for triple‐arc were about 50% less than those of IMRT plans, while there was no significant difference in the required MUs between triple‐arc and double‐arc RA plans. The peripheral dose in triple‐arc RA was found to be 50% less compared to IMRT near abdominal and pelvic region. Triple‐arc RA improves both the plan quality and treatment efficiency compared with IMRT for the treatment of early stage NPC. It has become the preferred choice of treatment delivery method for early stage NPC at our center. PACS numbers: 87.53.Bn, 87.55.D, 87.55.de, 87.55.dk, 87.56.ng PMID:23149781

  20. 2011 Annual Health Physics Report for the HEU transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2012-04-30

    During the 2008 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. They also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2008, there were 158 person-trips that required dose monitoring of the U.S. monitors. Of the 158 person-trips, 148 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 6 monitoring visits by TMO monitors to facilities other than UEIE and 8 to UEIE itself. There were three monitoringmore » visits (source changes) that were back-to-back with a total of 24 monitors. LLNL's Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors. In 2008, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency now has thirteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less

  1. 2008 Annual Health Physics Report for the HEU Transparency Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R.

    2009-03-24

    During the 2008 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. They also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2008, there were 158 person-trips that required dose monitoring of the U.S. monitors. Of the 158 person-trips, 148 person-trips were SMVs and 10 person-trips were Transparency Monitoring Office (TMO) trips. There were 6 monitoring visits by TMO monitors to facilities other than UEIE and 8 to UEIE itself. There were three monitoringmore » visits (source changes) that were back-to-back with a total of 24 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors. In 2008, the HEU Transparency activities in Russia were conducted in a radiologically safe manner for the HEU Transparency monitors in accordance with the expectations of the HEU Transparency staff, NNSA and DOE. The HEU Transparency now has thirteen years of successful experience in developing and providing health and safety support in meeting its technical objectives.« less

  2. Dose assessment of aircraft crew in The Netherlands.

    PubMed

    Van Dijk, J W E

    2003-01-01

    As the operator of the National Dose Registration and Information System, NRG has implemented a system for radiation exposure monitoring for the Dutch airlines. The system is based on the use of computer generated flight plans together with dose calculations using the CARI-6M program. Before installing the system a study was performed to estimate the uncertainty in the assessment of the annual dose of the crew members. It was concluded that the proposed system complies with international recommendations on the uncertainty in dose assessments in individual monitoring and that the operational costs of the system are low.

  3. Using operational equipment to read accident dosemeters.

    PubMed

    Devine, R T; Vigil, M M; Martinez, W A

    2004-01-01

    Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.

  4. Maywood Interim Storage Site environmental report for calendar year 1992, 100 West Hunter Avenue, Maywood, New Jersey. Formerly Utilized Sites Remedial Action Program (FUSRAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-05-01

    This report describes the environmental surveillance program at the Maywood Interim Storage Site (MISS) and provides the results for 1992. Environmental monitoring of MISS began in 1984, when the site was assigned to DOE by Congress through the Energy and Water Development Appropriations Act and was placed under DOE`s Formerly Utilized Sites Remedial Action Program (FUSRAP). FUSRAP was established to identify and decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation`s atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. MISS is part of amore » National Priorities List (NPL) site. The environmental surveillance program at MISS includes sampling networks for radon and thoron in air; external gamma radiation exposure; and radium-226, radium-228, thorium-232, and total uranium in surface water, sediment, and groundwater. Additionally, chemical analysis includes metals and organic compounds in surface water and groundwater and metals in sediments. This program assists in fulfilling the DOE objective of measuring and monitoring effluents from DOE activities and calculating hypothetical doses to members of the general public. Monitoring results are compared with applicable Environmental Protection Agency (EPA) and state standards, DOE derived concentration guides (DCGs), dose limits, and other DOE requirements. Environmental standards are established to protect public health and the environment. The radiological data for all media sampled support the conclusion that doses to the public are not distinguishable from natural background radiation.« less

  5. Lung function imaging methods in Cystic Fibrosis pulmonary disease.

    PubMed

    Kołodziej, Magdalena; de Veer, Michael J; Cholewa, Marian; Egan, Gary F; Thompson, Bruce R

    2017-05-17

    Monitoring of pulmonary physiology is fundamental to the clinical management of patients with Cystic Fibrosis. The current standard clinical practise uses spirometry to assess lung function which delivers a clinically relevant functional readout of total lung function, however does not supply any visible or localised information. High Resolution Computed Tomography (HRCT) is a well-established current 'gold standard' method for monitoring lung anatomical changes in Cystic Fibrosis patients. HRCT provides excellent morphological information, however, the X-ray radiation dose can become significant if multiple scans are required to monitor chronic diseases such as cystic fibrosis. X-ray phase-contrast imaging is another emerging X-ray based methodology for Cystic Fibrosis lung assessment which provides dynamic morphological and functional information, albeit with even higher X-ray doses than HRCT. Magnetic Resonance Imaging (MRI) is a non-ionising radiation imaging method that is garnering growing interest among researchers and clinicians working with Cystic Fibrosis patients. Recent advances in MRI have opened up the possibilities to observe lung function in real time to potentially allow sensitive and accurate assessment of disease progression. The use of hyperpolarized gas or non-contrast enhanced MRI can be tailored to clinical needs. While MRI offers significant promise it still suffers from poor spatial resolution and the development of an objective scoring system especially for ventilation assessment.

  6. Status of eye lens radiation dose monitoring in European hospitals.

    PubMed

    Carinou, Eleftheria; Ginjaume, Merce; O'Connor, Una; Kopec, Renata; Sans Merce, Marta

    2014-12-01

    A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.

  7. Development of a national cosmic-ray dose monitoring system with Health Canada's Fixed Point Surveillance network.

    PubMed

    Liu, Chuanlei; Zhang, Weihua; Ungar, Kurt; Korpach, Ed; White, Brian; Benotto, Mike; Pellerin, Eric

    2018-05-07

    This work explores the application of Health Canada's Fixed Point Surveillance (FPS) network for cosmic ray monitoring and dose estimation purposes. This network is comprised of RS250 3 inch by 3 inch Sodium Iodide (NaI) spectroscopic dosimeters distributed throughout Canada. The RS250's high channel count rate responds to the electromagnetic and muonic components of cosmic ray shower. These count rates are used to infer cosmic ray doses throughout FPS locations. The derived dose was found to have an accuracy within 6.5% deviation relative to theoretical calculation. The solar cycle effect and meteorologically induced fluctuation can be realistically reflected in the estimated dose. This work may serve as a basis to enable the FPS network to monitor and report both terrestrial and cosmic radiation in quasi-real time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  8. SU-E-T-91: Accuracy of Dose Calculation Algorithms for Patients Undergoing Stereotactic Ablative Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tajaldeen, A; Ramachandran, P; Geso, M

    2015-06-15

    Purpose: The purpose of this study was to investigate and quantify the variation in dose distributions in small field lung cancer radiotherapy using seven different dose calculation algorithms. Methods: The study was performed in 21 lung cancer patients who underwent Stereotactic Ablative Body Radiotherapy (SABR). Two different methods (i) Same dose coverage to the target volume (named as same dose method) (ii) Same monitor units in all algorithms (named as same monitor units) were used for studying the performance of seven different dose calculation algorithms in XiO and Eclipse treatment planning systems. The seven dose calculation algorithms include Superposition, Fastmore » superposition, Fast Fourier Transform ( FFT) Convolution, Clarkson, Anisotropic Analytic Algorithm (AAA), Acurous XB and pencil beam (PB) algorithms. Prior to this, a phantom study was performed to assess the accuracy of these algorithms. Superposition algorithm was used as a reference algorithm in this study. The treatment plans were compared using different dosimetric parameters including conformity, heterogeneity and dose fall off index. In addition to this, the dose to critical structures like lungs, heart, oesophagus and spinal cord were also studied. Statistical analysis was performed using Prism software. Results: The mean±stdev with conformity index for Superposition, Fast superposition, Clarkson and FFT convolution algorithms were 1.29±0.13, 1.31±0.16, 2.2±0.7 and 2.17±0.59 respectively whereas for AAA, pencil beam and Acurous XB were 1.4±0.27, 1.66±0.27 and 1.35±0.24 respectively. Conclusion: Our study showed significant variations among the seven different algorithms. Superposition and AcurosXB algorithms showed similar values for most of the dosimetric parameters. Clarkson, FFT convolution and pencil beam algorithms showed large differences as compared to superposition algorithms. Based on our study, we recommend Superposition and AcurosXB algorithms as the first choice of algorithms in lung cancer radiotherapy involving small fields. However, further investigation by Monte Carlo simulation is required to confirm our results.« less

  9. Executive summary: Weldon Spring Site Environmental Report for calendar year 1992. Weldon Spring Site Remedial Action Project, Weldon Spring, Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-06-01

    This report has been prepared to provide information about the public safety and environmental protection programs conducted by the Weldon Spring Site Remedial Action Project. The Weldon Spring site is located in southern St. Charles County, Missouri, approximately 48 km (30 mi) west of St. Louis. The site consists of two main areas, the Weldon Spring Chemical Plant and raffinate pits and the Weldon Spring Quarry. The objectives of the Site Environmental Report are to present a summary of data from the environmental monitoring program, to characterize trends and environmental conditions at the site, and to confirm compliance with environmentalmore » and health protection standards and requirements. The report also presents the status of remedial activities and the results of monitoring these activities to assess their impacts on the public and environment. The scope of the environmental monitoring program at the Weldon Spring site has changed since it was initiated. Previously, the program focused on investigations of the extent and level of contaminants in the groundwater, surface waters, buildings, and air at the site. In 1992, the level of remedial activities required monitoring for potential impacts of those activities, particularly on surface water runoff and airborne effluents. This report includes monitoring data from routine radiological and nonradiological sampling activities. These data include estimates of dose to the public from the Weldon Spring site; estimates of effluent releases; and trends in groundwater contaminant levels. Also, applicable compliance requirements, quality assurance programs, and special studies conducted in 1992 to support environmental protection programs are reviewed.« less

  10. SU-G-IeP3-13: Real-Time Patient and Staff Dose Monitoring in Fluoroscopy Guided Interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vergoossen, L; Sailer, A; Paulis, L

    Purpose: Interventional radiology procedures involve the use of X-rays, which can pose a large radiation burden on both patients and staff. Although some reports on radiation dose are available, most studies focus on limited types of procedures and only report patient dose. In our cathlabs a dedicated real-time patient and staff monitoring system was installed in November 2015. The aim of this study was to investigate the patient and staff dose exposure for different types of interventions. Methods: Radiologists involved in fluoroscopy guided interventional radiology procedures wore personal dose meters (PDM, DoseAware, Philips) on their lead-apron that measured the personalmore » dose equivalent Hp(10), a measure for the effective dose (E). Furthermore, reference PDMs were installed in the C-arms of the fluoroscopy system (Allura XPer, Philips). Patient dose-area-product (DAP) and PDM doses were retrieved from the monitoring system (DoseWise, Philips) for each procedure. A total of 399 procedures performed between November 2015 and February 2016 were analyzed with respect to the type of intervention. Interventions were grouped by anatomy and radiologist position. Results: The mean DAP for the different types of interventions ranged from 2.86±2.96 Gycm{sup 2} (percutaneous gastrostomy) to 147±178 Gycm{sup 2} (aortic repair procedures). The radiologist dose (E) ranged from 5.39±7.38 µSv (cerebral interventions) to 84.7±106 µSv (abdominal interventions) and strongly correlated with DAP (R{sup 2}=0.83). The E normalized to DAP showed that the relative radiologist dose was higher for interventions in larger body parts (e.g. abdomen) compared to smaller body parts (e.g. head). Conclusion: Using a real-time dose monitoring system we were able to assess the staff and patient dose revealing that the relative staff dose strongly depended on the type of procedure and patient anatomy. This could be explained by the position of the radiologist with respect to the patient and X-ray tube. To facilitate this study L Vergoossen received a scholarship from Philips Medical Systems.« less

  11. Potential hazard due to induced radioactivity secondary to radiotherapy: the report of task group 136 of the American Association of Physicists in Medicine.

    PubMed

    Thomadsen, Bruce; Nath, Ravinder; Bateman, Fred B; Farr, Jonathan; Glisson, Cal; Islam, Mohammad K; LaFrance, Terry; Moore, Mary E; George Xu, X; Yudelev, Mark

    2014-11-01

    External-beam radiation therapy mostly uses high-energy photons (x-rays) produced by medical accelerators, but many facilities now use proton beams, and a few use fast-neutron beams. High-energy photons offer several advantages over lower-energy photons in terms of better dose distributions for deep-seated tumors, lower skin dose, less sensitivity to tissue heterogeneities, etc. However, for beams operating at or above 10 MV, some of the materials in the accelerator room and the radiotherapy patient become radioactive due primarily to photonuclear reactions and neutron capture, exposing therapy staff and patients to unwanted radiation dose. Some recent advances in radiotherapy technology require treatments using a higher number of monitor units and monitor-unit rates for the same delivered dose, and compared to the conventional treatment techniques and fractionation schemes, the activation dose to personnel can be substantially higher. Radiotherapy treatments with proton and neutron beams all result in activated materials in the treatment room. In this report, the authors review critically the published literature on radiation exposures from induced radioactivity in radiotherapy. They conclude that the additional exposure to the patient due to induced radioactivity is negligible compared to the overall radiation exposure as a part of the treatment. The additional exposure to the staff due to induced activity from photon beams is small at an estimated level of about 1 to 2 mSv y. This is well below the allowed occupational exposure limits. Therefore, the potential hazard to staff from induced radioactivity in the use of high-energy x-rays is considered to be low, and no specific actions are considered necessary or mandatory. However, in the spirit of the "As Low as Reasonably Achievable (ALARA)" program, some reasonable steps are recommended that can be taken to reduce this small exposure to an even lower level. The dose reduction strategies suggested should be followed only if these actions are considered reasonable and practical in the individual clinics. Therapists working with proton beam and neutron beam units handle treatment devices that do become radioactive, and they should wear extremity monitors and make handling apertures and boluses their last task upon entering the room following treatment. Personnel doses from neutron-beam units can approach regulatory limits depending on the number of patients and beams, and strategies to reduce doses should be followed.

  12. Method to monitor HC-SCR catalyst NOx reduction performance for lean exhaust applications

    DOEpatents

    Viola, Michael B [Macomb Township, MI; Schmieg, Steven J [Troy, MI; Sloane, Thompson M [Oxford, MI; Hilden, David L [Shelby Township, MI; Mulawa, Patricia A [Clinton Township, MI; Lee, Jong H [Rochester Hills, MI; Cheng, Shi-Wai S [Troy, MI

    2012-05-29

    A method for initiating a regeneration mode in selective catalytic reduction device utilizing hydrocarbons as a reductant includes monitoring a temperature within the aftertreatment system, monitoring a fuel dosing rate to the selective catalytic reduction device, monitoring an initial conversion efficiency, selecting a determined equation to estimate changes in a conversion efficiency of the selective catalytic reduction device based upon the monitored temperature and the monitored fuel dosing rate, estimating changes in the conversion efficiency based upon the determined equation and the initial conversion efficiency, and initiating a regeneration mode for the selective catalytic reduction device based upon the estimated changes in conversion efficiency.

  13. Methadone.

    PubMed

    Chhabra, Shalini; Bull, Janet

    2008-01-01

    Methadone hydrochloride is an old drug that has been in vogue off and on. It has complex pharmacodynamics and can be potentially fatal in inexperienced settings. Drug switching from an opioid to methadone or vice versa requires knowledge of equianalgesic dosing. It is critical when using the drug to monitor for signs and symptoms of toxicity so that overdosing or toxicity can be identified in a timely manner. This review discusses these important topics so that methadone can be used safely and effectively.

  14. Thromboelastography Utilization in Delayed Recurrent Coagulopathy after Severe Eastern Diamondback Rattlesnake Envenomation.

    PubMed

    McBride, Katherine M; Bromberg, William; Dunne, James

    2017-04-01

    Venomous snakebites are fairly common in the United States and can present with a wide range of symptoms. A 48-year-old man presented after Eastern Diamondback rattlesnake envenomation. His hospital course was complicated by right leg compartment syndrome and delayed recurrent coagulopathy, requiring multiple doses of Crotalidae Polyvalent Immune Fab (CroFab) antivenom and transfusions. Thromboelastography was used as an adjunct to standard coagulation studies in monitoring his delayed recurrent coagulopathy.

  15. Chronic Medication and or Monitoring for Long Duration Space Flight: What Should The Policy Be?

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas R.

    2004-01-01

    While a private individual with a chronic medical condition could perhaps justifiably claim the right to become a "space tourist" through informed consent, NASA and other International crew members are national assets, trained at government expense to fulfill a mission considered essential to national goals. The medical requirements/policy for selection and certification of crewmembers for long duration missions to the International Space Station (ISS) should address: (1) Crewmembers with chronic conditions that require regular dosing of life-sustaining medication for the purposes of secondary or tertiary prevention (i.e. tumor suppression therapy or anticoagulation). (2) Crew members with conditions that will be worsened by spaceflight exposure, placing them at additional personal health risk though not necessarily increasing mission risk (i.e. previous radiation exposure or preflight osteopenia/osteoporosis) The following policies are recommended. A crewmember should not be assigned to an International Space Station mission who: (3) Requires medications to sustain life or who has a disease, which requires medical procedures or diagnostics to monitor and treat same. (4) Has medical condition, which would prevent participation as a candidate in many scientific and medical operational research studies, as their underlying condition would confound the collected data. (5) Requires specialized medical devices for monitoring or treatment of a medical condition, including conditions that require special provisions to conduct routine required countermeasure activities. (6) Who has a disease or requires treatment for same, and for which the effects of space travel may be deleterious to the short or long term health of the individual, An evidence-based approach will be used to provide rationale for policy recommendations under these scenarios. Operational impacts of allowing these medical conditions to fly on the ISS will also be presented.

  16. Dosimetry during intramedullary nailing of the tibia.

    PubMed

    Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George

    2009-10-01

    Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.

  17. AREA RADIATION MONITOR

    DOEpatents

    Manning, F.W.; Groothuis, S.E.; Lykins, J.H.; Papke, D.M.

    1962-06-12

    S>An improved area radiation dose monitor is designed which is adapted to compensate continuously for background radiation below a threshold dose rate and to give warning when the dose integral of the dose rate of an above-threshold radiation excursion exceeds a selected value. This is accomplished by providing means for continuously charging an ionization chamber. The chamber provides a first current proportional to the incident radiation dose rate. Means are provided for generating a second current including means for nulling out the first current with the second current at all values of the first current corresponding to dose rates below a selected threshold dose rate value. The second current has a maximum value corresponding to that of the first current at the threshold dose rate. The excess of the first current over the second current, which occurs above the threshold, is integrated and an alarm is given at a selected integrated value of the excess corresponding to a selected radiation dose. (AEC)

  18. A comprehensive dose reconstruction methodology for former rocketdyne/atomics international radiation workers.

    PubMed

    Boice, John D; Leggett, Richard W; Ellis, Elizabeth Dupree; Wallace, Phillip W; Mumma, Michael; Cohen, Sarah S; Brill, A Bertrand; Chadda, Bandana; Boecker, Bruce B; Yoder, R Craig; Eckerman, Keith F

    2006-05-01

    Incomplete radiation exposure histories, inadequate treatment of internally deposited radionuclides, and failure to account for neutron exposures can be important uncertainties in epidemiologic studies of radiation workers. Organ-specific doses from lifetime occupational exposures and radionuclide intakes were estimated for an epidemiologic study of 5,801 Rocketdyne/Atomics International (AI) radiation workers engaged in nuclear technologies between 1948 and 1999. The entire workforce of 46,970 Rocketdyne/AI employees was identified from 35,042 Kardex work histories cards, 26,136 electronic personnel listings, and 14,189 radiation folders containing individual exposure histories. To obtain prior and subsequent occupational exposure information, the roster of all workers was matched against nationwide dosimetry files from the Department of Energy, the Nuclear Regulatory Commission, the Landauer dosimetry company, the U.S. Army, and the U.S. Air Force. Dosimetry files of other worker studies were also accessed. Computation of organ doses from radionuclide intakes was complicated by the diversity of bioassay data collected over a 40-y period (urine and fecal samples, lung counts, whole-body counts, nasal smears, and wound and incident reports) and the variety of radionuclides with documented intake including isotopes of uranium, plutonium, americium, calcium, cesium, cerium, zirconium, thorium, polonium, promethium, iodine, zinc, strontium, and hydrogen (tritium). Over 30,000 individual bioassay measurements, recorded on 11 different bioassay forms, were abstracted. The bioassay data were evaluated using ICRP biokinetic models recommended in current or upcoming ICRP documents (modified for one inhaled material to reflect site-specific information) to estimate annual doses for 16 organs or tissues taking into account time of exposure, type of radionuclide, and excretion patterns. Detailed internal exposure scenarios were developed and annual internal doses were derived on a case-by-case basis for workers with committed equivalent doses indicated by screening criteria to be greater than 10 mSv to the organ with the highest internal dose. Overall, 5,801 workers were monitored for radiation at Rocketdyne/AI: 5,743 for external exposure and 2,232 for internal intakes of radionuclides; 41,169 workers were not monitored for radiation. The mean cumulative external dose based on Rocketdyne/AI records alone was 10.0 mSv, and the dose distribution was highly skewed with most workers experiencing low cumulative doses and only a few with high doses (maximum 500 mSv). Only 45 workers received greater than 200 mSv while employed at Rocketdyne/AI. However, nearly 32% (or 1,833) of the Rocketdyne/AI workers had been monitored for radiation at other nuclear facilities and incorporation of these doses increased the mean dose to 13.5 mSv (maximum 1,005 mSv) and the number of workers with >200 mSv to 69. For a small number of workers (n=292), lung doses from internal radionuclide intakes were relatively high (mean 106 mSv; maximum 3,560 mSv) and increased the overall population mean dose to 19.0 mSv and the number of workers with lung dose>200 mSv to 109. Nearly 10% of the radiation workers (584) were monitored for neutron exposures (mean 1.2 mSv) at Rocketdyne/AI, and another 2% were monitored for neutron exposures elsewhere. Interestingly, 1,477 workers not monitored for radiation at Rocketdyne/AI (3.6%) were found to have worn dosimeters at other nuclear facilities (mean external dose of 2.6 mSv, maximum 188 mSv). Without considering all sources of occupational exposure, an incorrect characterization of worker exposure would have occurred with the potential to bias epidemiologic results. For these pioneering workers in the nuclear industry, 26.5% of their total occupational dose (collective dose) was received at other facilities both prior to and after employment at Rocketdyne/AI. In addition, a small number of workers monitored for internal radionuclides contributed disproportionately to the number of workers with high lung doses. Although nearly 12% of radiation workers had been monitored for neutron exposures during their career, the cumulative dose levels were small in comparison with other external and internal exposure. Risk estimates based on nuclear worker data must be interpreted cautiously if internally deposited radionuclides and occupational doses received elsewhere are not considered.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podonsky, Glenn S.

    The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2012 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protectionmore » of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past 5-year period, the occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. As an indicator of the overall amount of radiation dose received during the conduct of operations at DOE, the report includes information on collective total effective dose (TED). The TED is comprised of the effective dose (ED) from external sources, which includes neutron and photon radiation, and the internal committed effective dose (CED), which results from the intake of radioactive material into the body. The collective ED from photon exposure decreased by 23% between 2011 and 2012, while the neutron dose increased by 5%. The internal dose components of the collective TED decreased by 7%. Over the past 5-year period, 99.99% of the individuals receiving measurable TED have received doses below the 2 roentgen equivalent in man (rems) (20 millisievert [mSv]) TED administrative control level (ACL), which is well below the DOE regulatory limit of 5 rems (50 mSv) TED annually. The occupational radiation exposure records show that in 2012, DOE facilities continued to comply with DOE dose limits and ACLs and worked to minimize exposure to individuals. The DOE collective TED decreased 17.1% from 2011 to 2012. The collective TED decreased at three of the five sites with the largest collective TED. u Idaho Site – Collective dose reductions were achieved as a result of continuing improvements at the Advanced Mixed Waste Treatment Project (AMWTP) through the planning of drum movements that reduced the number of times a container is handled; placement of waste containers that created highradiation areas in a centralized location; and increased worker awareness of high-dose rate areas. In addition, Idaho had the largest decrease in the total number of workers with measurable TED (1,143 fewer workers). u Hanford Site (Hanford) – An overall reduction of decontamination and decommissioning (D&D) activities at the Plutonium Finishing Plant (PFP) and Transuranic (TRU) retrieval activities resulted in collective dose reductions. u Savannah River Site (SRS) – Reductions were achieved through ALARA initiatives employed site wide. The Solid Waste Management Facility used extended specialty tools, cameras and lead shield walls to facilitate removal of drums. These tools and techniques reduce exposure time through improved efficiency, increase distance from the source of radiation by remote monitoring, shield the workers to lower the dose rate, and reduce the potential for contamination and release of material through repacking of waste. Overall, from 2011 to 2012, there was a 19% decrease in the number of workers with measurable dose. Furthermore, due to a slight decrease in both the DOE workforce (7%) and monitored workers (10%), the ratio of workers with measurable doses to monitored workers decreased to 13%. Another primary indicator of the level of radiation exposure covered in this report is the average measurable dose, which normalizes the collective dose over the population of workers who actually received a measurable dose. The average measurable TED increased by 3% from 2011 to 2012. Additional analyses show that the dose distribution in 2012 was similar to the distribution in 2011. In 2012, 13% of the monitored workers received a measurable TED and the average measurable TED, 0.069 rem, was less than 2% of the DOE limit. From 2011 to 2012, the collective TED and the number of individuals with measurable TED decreased 17.1% and 19%, respectively. These decreases were mainly due to an overall reduction of D&D activities at the PFP and TRU retrieval activities at Hanford; a 78% decrease in the number of targeted waste drums that were processed at the Idaho Site’s Accelerated Retrieval Project (ARP) from 5,566 drums in 2011 to a total of 1,211 drums processed in 2012; and ALARA initiatives employed site wide at SRS. In addition, the decreases were the result of decreased American Recovery and Reinvestment Act (ARRA) activities and continuing D&D, particularly at the DOE sites that comprise the majority of DOE collective dose. Over the past 5 years, the size of the monitored workforce has remained at a fairly stable level (within 12%), while the collective dose has varied up to 37%. No reported doses exceeded the DOE occupational limit of 5 rems TED in 2012 and no reported doses exceeded the DOE ACL of 2 rems TED.« less

  20. Monitoring Space Radiation Hazards with the Responsive Environmental Assessment Commercially Hosted (REACH) Project

    NASA Astrophysics Data System (ADS)

    Mazur, J. E.; Guild, T. B.; Crain, W.; Crain, S.; Holker, D.; Quintana, S.; O'Brien, T. P., III; Kelly, M. A.; Barnes, R. J.; Sotirelis, T.

    2017-12-01

    The Responsive Environmental Assessment Commercial Hosting (REACH) project uses radiation dosimeters on a commercial satellite constellation in low Earth orbit to provide unprecedented spatial and time sampling of space weather radiation hazards. The spatial and time scales of natural space radiation environments coupled with constraints for the hosting accommodation drove the instrumentation requirements and the plan for the final orbital constellation. The project has delivered a total of thirty two radiation dosimeter instruments for launch with each instrument containing two dosimeters with different passive shielding and electronic thresholds to address proton-induced single-event effects, vehicle charging, and total ionizing dose. There are two REACH instruments currently operating with four more planned for launch by the time of the 2017 meeting. Our aim is to field a long-lived system of highly-capable radiation detectors to monitor the hazards of single-event effects, total ionizing dose, and spacecraft charging with maximized spatial coverage and with minimal time latency. We combined a robust detection technology with a commercial satellite hosting to produce a new demonstration for satellite situational awareness and for other engineering and science applications.

  1. Physical Health and Drug Safety in Individuals with Schizophrenia

    PubMed Central

    Kelly, Martina; Urness, Doug; Teehan, Michael; Ismail, Zahinoor; Gardner, David

    2017-01-01

    Background: While antipsychotic medications are the mainstay of therapy for individuals with schizophrenia and psychotic disorders, their use is associated with adverse effects on physical health that require the attention and care of prescribers. Methods: We used the ADAPTE process to adapt existing guideline recommendations from the National Institute for Health and Care Excellence (NICE) and Scottish Intercollegiate Guidelines Network (SIGN) guidelines on the dosing of antipsychotics and antipsychotic polypharmacy, screening for adverse effects of antipsychotics, and management of metabolic and extrapyramidal side effects to the Canadian context. Results: Prescribers are encouraged to use the lowest effective dose and to avoid the routine use of multiple antipsychotics. Scheduled monitoring of body mass index, waist circumference, blood pressure, glucose, lipids, prolactin, electrocardiograms, and extrapyramidal symptoms is recommended. Lifestyle interventions are recommended to mitigate antipsychotic-induced weight gain. Prescribers should follow Canadian guidelines on the treatment of obesity, dyslipidemia, and diabetes. Recommendations on antipsychotic drug choice are made for users particularly concerned about extrapyramidal symptoms. Conclusion: Careful monitoring and attention by prescribers may mitigate adverse effects associated with antipsychotic medications. PMID:28718324

  2. Randomized prospective evaluation of cimetidine and antacid control of gastric pH in the critically ill.

    PubMed Central

    Stothert, J C; Simonowitz, D A; Dellinger, E P; Farley, M; Edwards, W A; Blair, A D; Cutler, R; Carrico, C J

    1980-01-01

    One hundred forty-four critically ill patients admitted to an intensive care setting were randomly assigned to cimetidine or antacid treatament groups. Gastric pH was monitored hourly. One hundred twenty-three (85%) patients demonstrated a fall in pH to less than 4 and were considered to require prophylaxis. Prophylaxis was considered adequate if the measured pH could then be maintained at greater than or equal to 4. Fifty-eight patients received antacids alone, the average requirement being 41 cc/hour. Sixty-five patients received cimetidine. Seventeen (26%) of the cimetidine prophylaxis patients failed to raise their pH and were than placed on hourly administration of antacid with successful elevations of pH to greater than or equal to 4 in all cases on an average supplementary dose of 53 cc/hour. Risk factors, including sepsis, hypotension, head injury, respiratory failure, degree of trauma, and age, were not statistically different in the two treated groups. Using these same criteria, responders to cimetidine could not be differentiated from nonresponders. All patients were protected from significant stress bleeding while on this study. Significant complications of either treatment were minimal. Antacids offered consistent protection against gastric acidity and were 100% effective. A routine schedule of 300 mg every six hours of cimetidine was effective in only 47% of patients, and the maximum dose of cimetidine was effective in only 74% of patients. Hourly measurement of intragastric pH is required for monitoring the response to prophylaxis of stress bleeding in severely ill patients. PMID:7406571

  3. Carbohydrate administration during a day of sustained aerobic activity improves vigilance, as assessed by a novel ambulatory monitoring device, and mood.

    PubMed

    Lieberman, Harris R; Falco, Christina M; Slade, Steven S

    2002-07-01

    The brain requires a continuous supply of glucose to function adequately. During aerobic exercise, peripheral glucose requirements increase and carbohydrate supplementation improves physical performance. The brain's utilization of glucose also increases during aerobic exercise. However, the effects of energy supplementation on cognitive function during sustained aerobic exercise are not well characterized. The effects of energy supplementation, as liquid carbohydrate, on cognitive function during sustained aerobic activity were examined. A double-blind, placebo-controlled, between-subjects design was used. Young, healthy men (n = 143) were randomly assigned to 1 of 3 treatment groups. The groups received either a 6% (by vol) carbohydrate (35.1 kJ/kg), 12% (by vol) carbohydrate (70.2 kJ/kg), or placebo beverage in 6 isovolumic doses, and all groups consumed 2 meals (3200 kJ). Over the 10-h study, the subjects performed physically demanding tasks, including a 19.3-km road march and two 4.8-km runs, interspersed with rest and other activities. Wrist-worn vigilance monitors, which emitted auditory stimuli (20/h) to which the subjects responded as rapidly as possible, and a standardized self-report mood questionnaire were used to assess cognitive function. Vigilance consistently improved with supplemental carbohydrates in a dose-related manner; the 12% carbohydrate group performed the best and the placebo group the worst (P < 0.001). Mood-questionnaire results corroborated the results from the monitors; the subjects who received carbohydrates reported less confusion (P = 0.040) and greater vigor (P = 0.025) than did those who received the placebo. Supplemental carbohydrate beverages enhance vigilance and mood during sustained physical activity and interspersed rest. In addition, ambulatory monitoring devices can continuously assess the effects of nutritional factors on cognition as individuals conduct their daily activities or participate in experiments.

  4. THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURES.

    PubMed

    Lopez, M A; Martin, R; Hernandez, C; Navarro, J F; Navarro, T; Perez, B; Sierra, I

    2016-09-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. SU-F-J-147: Magnetic Field Dose Response Considerations for a Linac Monitor Chamber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, M; Fallone, B

    Purpose: The impact of magnetic fields on the readings of a linac monitor chamber have not yet been investigated. Herein we examine the total dose response as well as any deviations in the beam parameters of flatness and symmetry when a Varian monitor chamber is irradiated within an applied magnetic field. This work has direct application to the development of Linac-MR systems worldwide. Methods: A Varian monitor chamber was modeled in the Monte Carlo code PENELOPE and irradiated in the presence of a magnetic field with a phase space generated from a model of a Linac-MR prototype system. The magneticmore » field strength was stepped from 0 to 3.0T in both parallel and perpendicular directions with respect to the normal surface of the phase space. Dose to each of the four regions in the monitor chamber were scored separately for every magnetic field adaptation to evaluate the effect of the magnetic field on flatness and symmetry. Results: When the magnetic field is perpendicular to the phase space normal we see a change in dose response with a maximal deviation (10–25% depending on the chamber region) near 0.75T. In the direction of electron deflection we expectedly see opposite responses in chamber regions leading to a measured asymmetry. With a magnetic field parallel to the phase space normal we see no measured asymmetries, however there is a monotonic rise in dose response leveling off at about +12% near 2.5T. Conclusion: Attention must be given to correct for the strength and direction of the magnetic field at the location of the linac monitor chamber in hybrid Linac-MR devices. Elsewise the dose sampled by these chambers may not represent the actual dose expected at isocentre; additionally there may be a need to correct for the symmetry of the beam recorded by the monitor chamber. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).« less

  6. Nevada Test Site Environmental Report 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cathy A. Wills

    2006-10-01

    The Nevada Test Site Environmental Report 2005 (NTSER) was prepared to meet the information needs of the public and the requirements and guidelines of the U.S. Department of Energy (DOE) for annual site environmental reports. Its purpose is to (1) report compliance status with environmental standards and requirements, (2) present results of environmental monitoring of radiological and nonradiological effluents, (3) report estimated radiological doses to the public from releases of radioactive material, (4) summarize environmental incidents of noncompliance and actions taken in response to them, (5) describe the NTS Environmental Management System and characterize its performance, and (6) highlight significantmore » environmental programs and efforts.« less

  7. Predicted blood glucose from insulin administration based on values from miscoded glucose meters.

    PubMed

    Raine, Charles H; Pardo, Scott; Parkes, Joan Lee

    2008-07-01

    The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205-210, 2007). It attempts to relate potential insulin dose errors to possible adverse blood glucose outcomes when glucose meters are miscoded. Five sets of glucose meters were used. Two sets of meters were autocoded and therefore could not be miscoded, and three sets required manual coding. Two of each set of manually coded meters were deliberately miscoded, and one from each set was properly coded. Subjects (n = 116) had finger stick blood glucose obtained at fasting, as well as at 1 and 2 hours after a fixed meal (Boost((R)); Novartis Medical Nutrition U.S., Basel, Switzerland). Deviations of meter blood glucose results from the reference method (YSI) were used to predict insulin dose errors and resultant blood glucose outcomes based on these deviations. Using insulin sensitivity data, it was determined that, given an actual blood glucose of 150-400 mg/dl, an error greater than +40 mg/dl would be required to calculate an insulin dose sufficient to produce a blood glucose of less than 70 mg/dl. Conversely, an error less than or equal to -70 mg/dl would be required to derive an insulin dose insufficient to correct an elevated blood glucose to less than 180 mg/dl. For miscoded meters, the estimated probability to produce a blood glucose reduction to less than or equal to 70 mg/dl was 10.40%. The corresponding probabilities for autocoded and correctly coded manual meters were 2.52% (p < 0.0001) and 1.46% (p < 0.0001), respectively. Furthermore, the errors from miscoded meters were large enough to produce a calculated blood glucose outcome less than or equal to 50 mg/dl in 42 of 833 instances. Autocoded meters produced zero (0) outcomes less than or equal to 50 mg/dl out of 279 instances, and correctly coded manual meters produced 1 of 416. Improperly coded blood glucose meters present the potential for insulin dose errors and resultant clinically significant hypoglycemia or hyperglycemia. Patients should be instructed and periodically reinstructed in the proper use of blood glucose meters, particularly for meters that require coding.

  8. TH-E-BRE-09: TrueBeam Monte Carlo Absolute Dose Calculations Using Monitor Chamber Backscatter Simulations and Linac-Logged Target Current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A, Popescu I; Lobo, J; Sawkey, D

    2014-06-15

    Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulationsmore » in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the TrueBeam MC literature. This work has been partially funded by Varian Medical Systems.« less

  9. Successful Graded Dose Challenge to Iodixanol Radiocontrast Media in a Patient With Delayed Anaphylaxis to Iohexol.

    PubMed

    Soffer, Gary; Cohen, Barrie; Toh, Jennifer; Edelman, Devorah; Garg, Karan; Jariwala, Sunit

    2018-01-01

    We present a case of an 82-year-old male with known radiocontrast media (RCM) hypersensitivity who was admitted to our hospital with gangrene of his right toe. The plan for revascularization of his lower extremity required an angiogram. This presented a management challenge as the patient had experienced 2 episodes of delayed anaphylaxis to Omnipaque (iohexol) RCM, and based on a literature review, there was no known or established precedent on a safe procedure in these situations. The patient was premedicated and given a graded dose challenge of an alternative RCM (iodixanol) prior to the radiographic study. He was given 1% of the total expected dose 1 hour before to the procedure and an additional 10% for the 30 minutes prior. He was then given the final dose in the operating room. Following angiogram, the patient was monitored for 18 hours in the postanesthesia care unit, with no adverse reactions. He was placed on a prednisone taper for 1 week, with daily diphenhydramine. The patient remained asymptomatic throughout the hospital course. This novel approach to RCM hypersensitivity management lends itself to a hope that graded dose challenges may play a greater role in the management of these patients.

  10. 42 CFR 82.2 - What are the basics of dose reconstruction?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... reconstructions may use monitoring results for groups of workers with comparable activities and relationships to... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... found to be complete and adequate, individual worker monitoring data, such as dosimeter readings and...

  11. 42 CFR 82.2 - What are the basics of dose reconstruction?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... reconstructions may use monitoring results for groups of workers with comparable activities and relationships to... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES METHODS FOR CONDUCTING DOSE RECONSTRUCTION UNDER THE... found to be complete and adequate, individual worker monitoring data, such as dosimeter readings and...

  12. Radiological Monitoring for Instructors. Student Workbook. Revised.

    ERIC Educational Resources Information Center

    Office of Civil Defense (DOD), Washington, DC.

    This student workbook includes the necessary materials and some of the references needed by each student during the conduct of the Radiological Monitoring for Instructors (RMI) course. The contents include a radiation exposure record, instrument exercise materials, fallout forecasting problems, dose and dose rate problems, source handling…

  13. Dosing and Monitoring of Methadone in Pregnancy: Literature Review

    PubMed Central

    Shiu, Jennifer R; Ensom, Mary H H

    2012-01-01

    Background: The pharmacokinetics of methadone is altered during pregnancy, but the most appropriate dosing and monitoring regimen has yet to be identified. Objective: To review dosing and monitoring of methadone therapy in pregnancy. Methods: A literature search was performed in several databases (PubMed, MEDLINE, Embase, International Pharmaceutical Abstracts, and the Cochrane Database of Systematic Reviews) from inception to May 2012. The search terms were “methadone”, “pregnancy”, “pharmacokinetic”, “clearance”, “metabolism”, “therapeutic drug monitoring”, and “methadone dosing”. Additional papers were identified by searching the bibliographies of primary and review articles. All English-language primary articles related to methadone pharmacokinetics in pregnancy were included. Articles not related to maternal outcomes were excluded. Results: The literature search yielded 1 case report and 10 studies discussing use of methadone by pregnant women. Methadone pharmacokinetics in pregnancy has been studied in 3 pharmacokinetic trials, and split dosing of methadone in pregnant women has been described in 1 case report and 3 dosing trials. Only 4 trials evaluated monitoring of methadone concentration in pregnancy. The studies included in this review confirm that methadone pharmacokinetics is altered in pregnancy and is potentially correlated with increases in maternal withdrawal symptoms. Insufficient evidence is available to warrant routine monitoring of serum methadone concentrations in pregnant women with opioid dependence. Conclusions: Few studies of methadone pharmacokinetics and therapeutic drug monitoring are available for pregnant women with opioid dependence. Although it is known that methadone pharmacokinetics is altered in pregnancy, there is insufficient evidence to guide dosage adjustments and serum concentration monitoring. Until further studies are available, regular follow-up of maternal withdrawal symptoms and empiric dosage adjustments throughout pregnancy are still recommended. PMID:23129867

  14. AREA MONITORING OF AMBIENT DOSE RATES IN PARTS OF SOUTH-WESTERN NIGERIA USING A GPS-INTEGRATED RADIATION SURVEY METER.

    PubMed

    Okeyode, I C; Rabiu, J A; Alatise, O O; Makinde, V; Akinboro, F G; Al-Azmi, D; Mustapha, A O

    2017-04-01

    A radiation monitoring system comprising a Geiger-Muller counter connected to a smart phone via Bluetooth was used for a dose rate survey in some parts of south-western Nigeria. The smart phone has the Geographical Positioning System, which provides the navigation information and saves it along with the dose rate data. A large number of data points was obtained that shows the dose rate distribution within the region. The results show that the ambient dose rates in the region range from 60 to 520 nSv -1 and showed a bias that is attributable to the influence of geology on the ambient radiation dose in the region. The geology influence was demonstrated by superimposing the dose rate plot and the geological map of the area. The potential applications of the device in determining baseline information and in area monitoring, e.g. for lost or abandoned sources, radioactive materials stockpiles, etc., were discussed in the article, particularly against the background of Nigeria's plan to develop its nuclear power program. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy.

    PubMed

    Higashigaito, K; Becker, A S; Sprengel, K; Simmen, H-P; Wanner, G; Alkadhi, H

    2016-09-01

    To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current-time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current-time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDIvol; p=0.62), dose-length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both -38%, p<0.017). Compared to cohort 1, CTDIvol, DLP, and ED in cohort 3 were significantly lower (all -25%, p<0.017), similar to the noise in the chest (-32%) and abdomen (-27%, both p<0.017). Compared to cohort 2, CTDIvol (-28%), DLP, and ED (both -26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Niagara Falls Storage Site annual environmental report for calendar year 1991, Lewiston, New York. [Niagara Falls Storage Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    This document describes the environmental monitoring program at the Niagara Falls Storage Site (NFSS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring at NFSS began in 1981. The site is owned by the US Department of Energy (DOE) and is assigned to the DOE Formerly Utilized Sites Remedial Action Program (FUSRAP). FUSRAP is a program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program atmore » NFSS includes sampling networks for radon concentrations in air; external gamma radiation exposure; and total uranium and radium-226 concentrations in surface water, sediments, and groundwater. Additionally, several nonradiological parameters including seven metals are routinely measured in groundwater. Monitoring results are compared with applicable Environmental Protection Agency (EPA) standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE orders. Environmental standards are established to protect public health and the environment.« less

  17. Niagara Falls Storage Site annual environmental report for calendar year 1991, Lewiston, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    This document describes the environmental monitoring program at the Niagara Falls Storage Site (NFSS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring at NFSS began in 1981. The site is owned by the US Department of Energy (DOE) and is assigned to the DOE Formerly Utilized Sites Remedial Action Program (FUSRAP). FUSRAP is a program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation`s atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program atmore » NFSS includes sampling networks for radon concentrations in air; external gamma radiation exposure; and total uranium and radium-226 concentrations in surface water, sediments, and groundwater. Additionally, several nonradiological parameters including seven metals are routinely measured in groundwater. Monitoring results are compared with applicable Environmental Protection Agency (EPA) standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE orders. Environmental standards are established to protect public health and the environment.« less

  18. [Radiation protection in interventional cardiology].

    PubMed

    Durán, Ariel

    2015-01-01

    INTERVENTIONAL: cardiology progress makes each year a greater number of procedures and increasing complexity with a very good success rate. The problem is that this progress brings greater dose of radiation not only for the patient but to occupationally exposed workers as well. Simple methods for reducing or minimizing occupational radiation dose include: minimizing fluoroscopy time and the number of acquired images; using available patient dose reduction technologies; using good imaging-chain geometry; collimating; avoiding high-scatter areas; using protective shielding; using imaging equipment whose performance is controlled through a quality assurance programme; and wearing personal dosimeters so that you know your dose. Effective use of these methods requires both appropriate education and training in radiation protection for all interventional cardiology personnel, and the availability and use of appropriate protective tools and equipment. Regular review and investigation of personnel monitoring results, accompanied as appropriate by changes in how procedures are performed and equipment used, will ensure continual improvement in the practice of radiation protection in the interventional suite. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  19. Chemical restraint and anaesthetic effects of a tiletamine-zolazepam/ketamine/detomidine combination in cattle.

    PubMed

    Re, Michela; Blanco-Murcia, Francisco J; Gómez de Segura, Ignacio A

    2011-10-01

    The immobilisation and anaesthesia of free-ranging cattle requires the administration of appropriate drugs in small volume via rifle or dart. The objective of this randomised controlled study was to test the capacity of a concentrated combination of tiletamine-zolazepam (TZ), ketamine (K) and detomidine (D) (TZKD) to immobilise/anaesthetise calves. Following administration of low, medium and high doses of TZKD to six healthy animals IM, the time-of-onset and duration of anaesthesia were recorded, in addition to standard cardio-respiratory parameters. Two noxious stimuli were applied to assess the analgesic effect of the combination. TZKD produced a dose-dependent anaesthetic action associated with respiratory depression and moderate hypoxaemia. Total recumbency lasted from 1h (with low dose) to 2h (with medium and high doses). The findings indicate that TZKD induces anaesthesia in calves, suitable not only for animal immobilisation, but also to carry out minor surgical procedures with or without additional local analgesia. Respiratory depression was the most severe side-effect and careful patient monitoring is recommended when using this drug combination. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Intensity-modulated radiotherapy in the standard management of head and neck cancer: promises and pitfalls.

    PubMed

    Mendenhall, William M; Amdur, Robert J; Palta, Jatinder R

    2006-06-10

    The purpose of this article is to review the role of intensity-modulated radiotherapy (IMRT) in the standard management of patients with head and neck cancer through a critical review of the pertinent literature. IMRT may result in a dose distribution that is more conformal than that achieved with three-dimensional conformal radiotherapy (3D CRT), allowing dose reduction to normal structures and thus decreasing toxicity and possibly enhancing locoregional control through dose escalation. Disadvantages associated with IMRT include increased risk of a marginal miss, decreased dose homogeneity, increased total body dose, and increased labor and expense. Outcomes data after IMRT are limited, and follow-up is relatively short. Locoregional control rates appear to be comparable to those achieved with 3D CRT and, depending on the location and extent of the tumor, late toxicity may be lower. Despite limited data on clinical outcomes, IMRT has been widely adopted as a standard technique in routine practice and clinical trials. The use of IMRT involves a learning curve for the practitioner and will continue to evolve, requiring continuing education and monitoring of outcomes from routine practice. Additional standards pertaining to a variety of issues, including target definitions and dose specification, need to be developed. Phase III trials will better define the role of IMRT in coming years.

  1. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Imad, E-mail: iali@ouhsc.edu; Ahmad, Salahuddin

    2013-10-01

    To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatmentmore » sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.« less

  2. Estimation of patient-specific imaging dose for real-time tumour monitoring in lung patients during respiratory-gated radiotherapy

    NASA Astrophysics Data System (ADS)

    Shiinoki, Takehiro; Onizuka, Ryota; Kawahara, Daisuke; Suzuki, Tatsuhiko; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Hanazawa, Hideki; Shibuya, Keiko

    2018-03-01

    Purpose: To quantify the patient-specific imaging dose for real-time tumour monitoring in the lung during respiratory-gated stereotactic body radiotherapy (SBRT) in clinical cases using SyncTraX. Methods and Materials: Ten patients who underwent respiratory-gated SBRT with SyncTraX were enrolled in this study. The imaging procedure for real-time tumour monitoring using SyncTraX was simulated using Monte Carlo. We evaluated the dosimetric effect of a real-time tumour monitoring in a critical organ at risk (OAR) and the planning target volume (PTV) over the course of treatment. The relationship between skin dose and gating efficiency was also investigated. Results: For all patients, the mean D50 to the PTV, ipsilateral lung, liver, heart, spinal cord and skin was 118.3 (21.5–175.9), 31.9 (9.5–75.4), 15.4 (1.1–31.6), 10.1 (1.3–18.1), 25.0 (1.6–101.8), and 3.6 (0.9–7.1) mGy, respectively. The mean D2 was 352.0 (26.5–935.8), 146.4 (27.3–226.7), 90.7 (3.6–255.0), 42.2 (4.8–82.7), 88.0 (15.4–248.5), and 273.5 (98.3–611.6) mGy, respectively. The D2 of the skin dose was found to increase as the gating efficiency decreased. Conclusions: The additional dose to the PTV was at most 1.9% of the prescribed dose over the course of treatment for real-time tumour monitoring. For OARs, we could confirm the high dose region, which may not be susceptible to radiation toxicity. However, to reduce the skin dose from SyncTraX, it is necessary to increase the gating efficiency.

  3. Results of a 10-year survey of workload for 10 treatment vaults at a high-throughput comprehensive cancer center.

    PubMed

    Saleh, Ziad H; Jeong, Jeho; Quinn, Brian; Mechalakos, James; St Germain, Jean; Dauer, Lawrence T

    2017-05-01

    The workload for shielding purposes of modern linear accelerators (linacs) consists of primary and scatter radiation which depends on the dose delivered to isocenter (cGy) and leakage radiation which depends on the monitor units (MUs). In this study, we report on the workload for 10 treatment vaults in terms of dose to isocenter (cGy), monitor units delivered (MUs), number of treatment sessions (Txs), as well as, use factors (U) and modulation factors (CI) for different treatment techniques. The survey was performed for the years between 2006 and 2015 and included 16 treatment machines which represent different generations of Varian linear accelerators (6EX, 600C, 2100C, 2100EX, and TrueBeam) operating at different electron and x-ray energies (6, 9, 12, 16 and 20 MeV electrons and, 6 and 15 MV x-rays). An institutional review board (IRB) approval was acquired to perform this study. Data regarding patient workload, dose to isocenter, number of monitor units delivered, beam energies, gantry angles, and treatment techniques were exported from an ARIA treatment management system (Varian Medical Systems, Palo Alto, Ca.) into Excel spreadsheets and data analysis was performed in Matlab. The average (± std-dev) number of treatment sessions, dose to isocenter, and number of monitor units delivered per week per machine in 2006 was 119 ± 39 Txs, (300 ± 116) × 10 2 cGys, and (78 ± 28) × 10 3 MUs respectively. In contrast, the workload in 2015 was 112 ± 40 Txs, (337 ± 124) × 10 2 cGys, and (111 ± 46) × 10 3 MUs. 60% of the workload (cGy) was delivered using 6 MV and 30% using 15 MV while the remaining 10% was delivered using electron beams. The modulation factors (MU/cGy) for IMRT and VMAT were 5.0 (± 3.4) and 4.6 (± 1.6) respectively. Use factors using 90° gantry angle intervals were equally distributed (~0.25) but varied considerably among different treatment techniques. The workload, in terms of dose to isocenter (cGy) and subsequently monitor units (MUs), has been steadily increasing over the past decade. This increase can be attributed to increased use of high dose hypo-fractionated regimens (SBRT, SRS) and the increase in use of IMRT and VMAT, which require higher MUs per cGy as compared to more conventional treatment (3DCRT). Meanwhile, the patient workload in terms of treatment sessions per week remained relatively constant. The findings of this report show that variables used for shielding purposes still fall within the recommendation of NCRP Report 151. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. A Systematic Analysis of 2 Monoisocentric Techniques for the Treatment of Multiple Brain Metastases.

    PubMed

    Narayanasamy, Ganesh; Stathakis, Sotirios; Gutierrez, Alonso N; Pappas, Evangelos; Crownover, Richard; Floyd, John R; Papanikolaou, Niko

    2017-10-01

    In this treatment planning study, we compare the plan quality and delivery parameters for the treatment of multiple brain metastases using 2 monoisocentric techniques: the Multiple Metastases Element from Brainlab and the RapidArc volumetric-modulated arc therapy from Varian Medical Systems. Eight patients who were treated in our institution for multiple metastases (3-7 lesions) were replanned with Multiple Metastases Element using noncoplanar dynamic conformal arcs. The same patients were replanned with the RapidArc technique in Eclipse using 4 noncoplanar arcs. Both techniques were designed using a single isocenter. Plan quality metrics (conformity index, homogeneity index, gradient index, and R 50% ), monitor unit, and the planning time were recorded. Comparison of the Multiple Metastases Element and RapidArc plans was performed using Shapiro-Wilk test, paired Student t test, and Wilcoxon signed rank test. A paired Wilcoxon signed rank test between Multiple Metastases Element and RapidArc showed comparable plan quality metrics and dose to brain. Mean ± standard deviation values of conformity index were 1.8 ± 0.7 and 1.7 ± 0.6, homogeneity index were 1.3 ± 0.1 and 1.3 ± 0.1, gradient index were 5.0 ± 1.8 and 5.1 ± 1.9, and R 50% were 4.9 ± 1.8 and 5.0 ± 1.9 for Multiple Metastases Element and RapidArc plans, respectively. Mean brain dose was 2.3 and 2.7 Gy for Multiple Metastases Element and RapidArc plans, respectively. The mean value of monitor units in Multiple Metastases Element plan was 7286 ± 1065, which is significantly lower than the RapidArc monitor units of 9966 ± 1533 ( P < .05). For the planning of multiple brain lesions to be treated with stereotactic radiosurgery, Multiple Metastases Element planning software produced equivalent conformity, homogeneity, dose falloff, and brain V 12 Gy but required significantly lower monitor units, when compared to RapidArc plans.

  5. A Systematic Analysis of 2 Monoisocentric Techniques for the Treatment of Multiple Brain Metastases

    PubMed Central

    Stathakis, Sotirios; Gutierrez, Alonso N.; Pappas, Evangelos; Crownover, Richard; Floyd, John R.; Papanikolaou, Niko

    2016-01-01

    Background: In this treatment planning study, we compare the plan quality and delivery parameters for the treatment of multiple brain metastases using 2 monoisocentric techniques: the Multiple Metastases Element from Brainlab and the RapidArc volumetric-modulated arc therapy from Varian Medical Systems. Methods: Eight patients who were treated in our institution for multiple metastases (3-7 lesions) were replanned with Multiple Metastases Element using noncoplanar dynamic conformal arcs. The same patients were replanned with the RapidArc technique in Eclipse using 4 noncoplanar arcs. Both techniques were designed using a single isocenter. Plan quality metrics (conformity index, homogeneity index, gradient index, and R50%), monitor unit, and the planning time were recorded. Comparison of the Multiple Metastases Element and RapidArc plans was performed using Shapiro-Wilk test, paired Student t test, and Wilcoxon signed rank test. Results: A paired Wilcoxon signed rank test between Multiple Metastases Element and RapidArc showed comparable plan quality metrics and dose to brain. Mean ± standard deviation values of conformity index were 1.8 ± 0.7 and 1.7 ± 0.6, homogeneity index were 1.3 ± 0.1 and 1.3 ± 0.1, gradient index were 5.0 ± 1.8 and 5.1 ± 1.9, and R50% were 4.9 ± 1.8 and 5.0 ± 1.9 for Multiple Metastases Element and RapidArc plans, respectively. Mean brain dose was 2.3 and 2.7 Gy for Multiple Metastases Element and RapidArc plans, respectively. The mean value of monitor units in Multiple Metastases Element plan was 7286 ± 1065, which is significantly lower than the RapidArc monitor units of 9966 ± 1533 (P < .05). Conclusion: For the planning of multiple brain lesions to be treated with stereotactic radiosurgery, Multiple Metastases Element planning software produced equivalent conformity, homogeneity, dose falloff, and brain V12 Gy but required significantly lower monitor units, when compared to RapidArc plans. PMID:27612917

  6. Azathioprine-Induced Warfarin Resistance

    PubMed Central

    Vazquez, Sara R; Rondina, Matthew T; Pendleton, Robert C

    2011-01-01

    OBJECTIVE To describe a case of azathioprine-induced warfarin resistance, present a literature review on warfarin–azathioprine interactions, and provide recommendations on appropriate management of this clinically significant interaction. CASE SUMMARY A 29-year-old female with Cogan’s syndrome experienced thrombosis of the left internal carotid artery. She was treated with an average weekly warfarin dose of 39 mg (5.5 mg daily) prior to beginning azathioprine therapy. Three weeks following initiation of azathioprine 150 mg daily, the international normalized ratio (INR) decreased from 1.9 (prior to the medication change) to 1.0 without any change in the warfarin dose or other relevant factors. Over several weeks, the patient’s warfarin dose was titrated up to 112 mg weekly (16 mg daily) to achieve an INR of 2.5 (a 188%, or 2.9-fold dose increase). Because of elevated liver enzyme levels, the azathioprine dosage was decreased to 100 mg daily. Within 2 weeks following that decrease, warfarin requirements decreased to 105 mg weekly (15 mg daily). DISCUSSION Azathioprine was the probable causative agent of warfarin resistance according to the Naranjo probability scale, and a possible causative agent according to the Drug Interaction Probability Scale. A literature search (PubMed, 1966–December 2007) revealed 8 case reports of this drug interaction and 2 cases involving a similar effect with 6-mercaptopurine, the active metabolite of azathioprine. The exact mechanism of the interaction remains unknown. Previously published case reports point to a rapid onset and offset of the warfarin–azathioprine interaction and a dose-dependent increase of at least 2.5-fold in warfarin dose requirement with the initiation of azathioprine 75–200 mg daily. CONCLUSIONS This case report and several others point toward azathioprine as a clinically significant inducer of warfarin resistance. Providers should anticipate the need for higher warfarin doses, warfarin dose adjustment, and close INR monitoring in patients receiving azathioprine or its active metabolite, 6-mercaptopurine. PMID:18505911

  7. Annual environmental monitoring report of the Lawrence Berkeley Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schleimer, G.E.

    1983-04-01

    In order to establish whether LBL research activities produces any impact on the population surrounding the Laboratory, a program of environmental air and water sampling and continuous radiation monitoring was carried on throughout the year. For 1982, as in the previous several years, doses attributable to LBL radiological operations were a small fraction of the relevant radiation protection guidelines (RPG). The maximum perimeter dose equivalent was less than or equal to 24.0 mrem (the 1982 dose equivalent measured at the Building 88 monitoring station B-13A, about 5% of the RPG). The total population dose equivalent attributable to LBL operations duringmore » 1982 was less than or equal to 16 man-rem, about 0.002% of the RPG of 170 mrem/person to a suitable sample of the population.« less

  8. Thermoluminescent dosimetry in rotary-dual technique of the total skin electron irradiation.

    PubMed

    Piotrowski, T; Fundowicz, D; Pawlaczyk, M; Malicki, J

    2003-01-01

    The aim of the study was to discuss the results of thermoluminescent dosimetry (TLD) in rotary-dual technique of the total skin electron irradiation (TSEI RD), to confirm beam calibration and monitor unit calculations and to provide data for making clinical decisions. Between May 2001 and April 2002, in 3 cases of mycosis fungoides, 736 dosimetric checks were performed in 34 points at the skin. CaF2:MnTLD-400 cubes (1/8"x1/8"x0.015") were used for in vivo dosimetry. Doses were computed and analyzed for all locations. Percent of described dose and SD for the following localizations from 34 points were: anterior abdomen (reference point) 100+/-6%, upper back 100+/-8%, right calf 98+/-10%, left foot (mid dorsum) 97+/-8%, posterior neck 93+/-6%, right hand (mid dorsum) 78+/-10%, hand fingers 57+/-10%, top of right shoulder 56+/-14%, left groin 35+/-20%, perineum 22+/-17%. The correlations between patient's height and measured doses were sufficient for the following localizations: scalp (top rear), occiput, elbows, hand fingers and hands (mid dorsum). The correlations between obesity index and measured doses were sufficient for the following localizations: shoulders and lateral neck, groins, and perineum. Dosimetric checks at the reference point confirm that our beam calibration technique and monitor unit calculation are accurate. TLD shows that for some parts of the skin such as shoulder, hands and perineum boost fields were required. The correlations with obesity index and height for several sites suggest that boost fields must be customized for each patient.

  9. Effect of Dose of Behavioral Treatment for Obesity on Binge Eating Severity

    PubMed Central

    Ariel, Aviva H.; Perri, Michael G.

    2016-01-01

    Objectives We evaluated the effects of three doses of a behavioral intervention for obesity (High dose = 24 sessions, Moderate = 16 sessions, Low = 8 sessions) compared with a nutrition education control group (Control) on binge eating. We also examined whether participants with clinically significant improvements in binge eating had better treatment adherence and weight-loss outcomes than those who did not experience clinically significant improvements in binge eating. Finally, we examined the relation of pretreatment binge eating severity to changes at six months. Methods Participants included 572 adults (female = 78.7%; baseline mean ±SD: age = 52.7 ±11.2 years, BMI = 36.4 ±3.9 kg/m2) who provided binge eating data at baseline. We evaluated binge eating severity (assessed via the Binge Eating Scale) and weight status at baseline and six months, as well as treatment adherence over six months. Results At six months, participants in the Moderate and High treatment conditions reported greater reductions in binge eating severity than participants in the Low and Control conditions, ps < .02. Participants who demonstrated improvements in binge eating severity reported greater dietary self-monitoring adherence and attained larger weight losses than those who did not experience clinically significant reductions, ps < .001. Pretreatment binge eating severity predicted less improvement in binge eating severity over six months and fewer days with dietary self-monitoring records completed, ps ≤ .002. Conclusion A moderate or high dose of behavioral weight-loss treatment may be required to produce clinically significant reductions in binge eating severity in adults with obesity. PMID:27086049

  10. Patient radiation exposure during different kyphoplasty techniques.

    PubMed

    Panizza, Denis; Barbieri, Massimo; Parisoli, Francesco; Moro, Luca

    2014-01-01

    The scope of this study was to quantify patient radiation exposure during two different techniques of kyphoplasty (KP), which differ by a cement delivery method, in order to assess whether or not one of the two used methods can reduce the patient dose. Twenty patients were examined for this investigation. One X-ray fluoroscopy unit was used for localization, navigation and monitoring of cement delivery. The patient biometric data, the setting of the fluoroscope, the exposure time and the kerma-area product (KAP) were monitored in all the procedures for anteroposterior (AP) and lateral (LL) fluoroscopic projections in order to assess the range of radiation doses imparted to the patient. Theoretical entrance skin dose (ESD) and effective dose (E) were calculated from intraoperatively measured KAP. An average ET per procedure was 1.5±0.5 min for the manual injection technique (study A) and 1.4±0.4 min for the distance delivery technique (study B) in the AP plane, while 3.2±0.7 and 5.1±0.6 min in the lateral plane, respectively. ESD was estimated as an average of 0.10±0.06 Gy for study A and 0.13±0.13 Gy for study B in the AP or/and 0.59±0.46 and 1.05±0.36 Gy in the lateral view, respectively. The cumulative mean E was 1.9±1.0 mSv procedure(-1) for study A and 3.6±0.9 mSv procedure(-1) for study B. Patient radiation exposure and associated effective dose from KP may be considerable. The technique of distance cement delivery appears to be slower than the manual injection technique and it requires a more protracted fluoroscopic control in the lateral projection, so that this system entails a higher amount of dose to the patient.

  11. SU-G-BRC-14: Multi-Lesion, Multi-Rx, Brain Radiosurgery with Novel Single Isocenter Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Honig, N; Alani, S; Schlocker, A

    Purpose: There is a strong trend to treat multiple brain metastases with radiosurgery rather than whole brain irradiation. This feasibility study investigates a novel planning technique for radio-surgical treatment of multiple brain lesions with differing dose prescriptions, a single isocenter, and dynamic conformal arcs. The novel technique will be compared to the well-established single-isocenter volumetric modulated arc therapy (VMAT) technique commonly used for treating brain lesions. Methods: Six patients with metastatic brain lesions were selected for a prospective treatment planning study to evaluate Interdigitating MLC Dynamic Conformal Arc (IMDCA) technique. Arcs were planned for simultaneous irradiation to maximize beam deliverymore » efficiency. To accommodate varying PTV dose prescriptions, selected arcs were re-irradiated in reverse. Beam weights were adjusted until all prescription constraints were met. The number of lesions ranged between 2 to 4 (mode = 3). For comparison, SRS VMAT plans were generated utilizing an established single-isocenter, 3 arc planning template. All plans were compared by means of Paddick conformity index (PCI), RTOG Conformity Index (RCI), gradient index (GI), and the normal brain volume receiving 10% (V10) of the highest prescription dose. The monitor units and delivery time were tabulated for each plan. Results: IMDCA achieved conformal plans (PCI = 0.72±0.03, RCI = 1.33±0.03) with steep dose fall-off (GI = 3.79±0.03) on average for all of the plans evaluated. The VMAT plans had slightly better conformity (PCI = 0.85 ± 0.03, RCI = 1.13 ± 0.03) than IMDCA, but overall worse GI (4.29 ± 0.06). IMDCA plans had lower V10% values, required 50% fewer MUs, and had 34% shorter beam delivery time on average compared to VMAT plans. Conclusion: IMDCA plans with varying dose prescriptions for multiple lesions, had comparable dosimetric coverage as VMAT plans, but were obtained with significantly lower integral dose, fewer monitor units, and quicker delivery time.« less

  12. Fanconi Syndrome Secondary to Deferasirox in Diamond-Blackfan Anemia: Case Series and Recommendations for Early Diagnosis.

    PubMed

    Papneja, Koyelle; Bhatt, Mihir D; Kirby-Allen, Melanie; Arora, Steven; Wiernikowski, John T; Athale, Uma H

    2016-08-01

    Deferasirox is an oral iron chelator used to treat patients with transfusion-related iron overload. We report, from two institutions, two children with Diamond-Blackfan anemia who developed Fanconi syndrome secondary to deferasirox administration, along with a review of the literature. The current recommendation for the laboratory monitoring of patients receiving deferasirox does not include serum electrolytes or urine analysis. Thus, despite routine clinic visits and bloodwork, these two patients presented with life-threatening electrolyte abnormalities requiring hospitalization. Hence, we propose the inclusion of serum electrolytes and urine analysis as part of routine monitoring to facilitate the early diagnosis of Fanconi syndrome in the context of high doses of deferasirox therapy. © 2016 Wiley Periodicals, Inc.

  13. Regulation Catches Up to Reality.

    PubMed

    Edelman, Steven V

    2017-01-01

    The FDA recently conducted an Advisory Panel meeting to evaluate the safety, efficacy, and benefits of granting a nonadjunctive label claim for the DEXCOM G5 Mobile continuous glucose monitoring (CGM) system. If approved, this claim will allow users to make day-to-day treatment decisions, including insulin dosing directly from the glucose values and rate of changes arrows generated by the CGM device, without the requirement of a confirmatory measurement with a self-monitoring blood glucose (SMBG) meter. Sporadic SMBG testing gives limited data, while CGM gives a value every 5 minutes and has alerts, alarms, trending information and allows caregivers to follow the user in real time 24/7. This indication will lead to more wide spread use of CGM and improve overall care with protection of hypoglycemia.

  14. Study for online range monitoring with the interaction vertex imaging method.

    PubMed

    Finck, Ch; Karakaya, Y; Reithinger, V; Rescigno, R; Baudot, J; Constanzo, J; Juliani, D; Krimmer, J; Rinaldi, I; Rousseau, M; Testa, E; Vanstalle, M; Ray, C

    2017-11-21

    Ion beam therapy enables a highly accurate dose conformation delivery to the tumor due to the finite range of charged ions in matter (i.e. Bragg peak (BP)). Consequently, the dose profile is very sensitive to patients anatomical changes as well as minor mispositioning, and so it requires improved dose control techniques. Proton interaction vertex imaging (IVI) could offer an online range control in carbon ion therapy. In this paper, a statistical method was used to study the sensitivity of the IVI technique on experimental data obtained from the Heidelberg Ion-Beam Therapy Center. The vertices of secondary protons were reconstructed with pixelized silicon detectors. The statistical study used the [Formula: see text] test of the reconstructed vertex distributions for a given displacement of the BP position as a function of the impinging carbon ions. Different phantom configurations were used with or without bone equivalent tissue and air inserts. The inflection points in the fall-off region of the longitudinal vertex distribution were computed using different methods, while the relation with the BP position was established. In the present setup, the resolution of the BP position was about 4-5 mm in the homogeneous phantom under clinical conditions (10 6 incident carbon ions). Our results show that the IVI method could therefore monitor the BP position with a promising resolution in clinical conditions.

  15. The pharmacokinetics of a single oral or rectal dose of concurrently administered isoniazid, rifampin, pyrazinamide, and ethambutol in Asian elephants (Elephas maximus).

    PubMed

    P Brock, A; Isaza, R; Egelund, E F; Hunter, R P; Peloquin, C A

    2014-10-01

    Tuberculosis, caused by Mycobacterium tuberculosis, is a disease of concern in captive Asian elephants (Elephas maximus). Treatment for tuberculosis in elephants utilizes multidrug protocols combining isoniazid, rifampin, pyrazinamide, and/or ethambutol. In this study, a single, coformulated dose of isoniazid 5 mg/kg, rifampin 10 mg/kg, pyrazinamide 30 mg/kg, and ethambutol 30 mg/kg was administered orally to six Asian elephants, and rectally to five elephants using a cross-over design. Blood samples were collected serially over 24 h. Pyrazinamide and ethambutol concentrations were determined using validated gas chromatography assays. Isoniazid and rifampin concentrations were determined using validated high-performance liquid chromatography assays. Rectal isoniazid produced an earlier Tmax compared with oral administration. Oral isoniazid resulted in a comparatively lower Cmax , but higher AUC values compared with rectal isoniazid. Oral rifampin and oral ethambutol were well absorbed while rectal rifampin was not. Oral pyrazinamide produced comparatively higher Cmax and AUC values compared with rectal pyrazinamide. Results of this study indicate that currently recommended therapeutic monitoring sample collection times for rectal isoniazid and oral rifampin do not provide an accurate assessment of exposure for these drugs. This study demonstrates notable individual variability, indicating that dosing of these medications requires individual monitoring and provides additional information to guide the clinician when treating elephants. © 2014 John Wiley & Sons Ltd.

  16. Study for online range monitoring with the interaction vertex imaging method

    NASA Astrophysics Data System (ADS)

    Finck, Ch; Karakaya, Y.; Reithinger, V.; Rescigno, R.; Baudot, J.; Constanzo, J.; Juliani, D.; Krimmer, J.; Rinaldi, I.; Rousseau, M.; Testa, E.; Vanstalle, M.; Ray, C.

    2017-12-01

    Ion beam therapy enables a highly accurate dose conformation delivery to the tumor due to the finite range of charged ions in matter (i.e. Bragg peak (BP)). Consequently, the dose profile is very sensitive to patients anatomical changes as well as minor mispositioning, and so it requires improved dose control techniques. Proton interaction vertex imaging (IVI) could offer an online range control in carbon ion therapy. In this paper, a statistical method was used to study the sensitivity of the IVI technique on experimental data obtained from the Heidelberg Ion-Beam Therapy Center. The vertices of secondary protons were reconstructed with pixelized silicon detectors. The statistical study used the χ2 test of the reconstructed vertex distributions for a given displacement of the BP position as a function of the impinging carbon ions. Different phantom configurations were used with or without bone equivalent tissue and air inserts. The inflection points in the fall-off region of the longitudinal vertex distribution were computed using different methods, while the relation with the BP position was established. In the present setup, the resolution of the BP position was about 4-5 mm in the homogeneous phantom under clinical conditions (106 incident carbon ions). Our results show that the IVI method could therefore monitor the BP position with a promising resolution in clinical conditions.

  17. MANAGING INTERNAL RADIATION CONTAMINATION FOLLOWING AN EMERGENCY: IDENTIFICATION OF GAPS AND PRIORITIES

    PubMed Central

    Li, Chunsheng; Ansari, Armin; Etherington, George; Jourdain, Jean-Rene; Kukhta, Boris; Kurihara, Osamu; Lopez, Maria Antonia; Ménétrier, Florence; dos Reis, Arlene Alves; Solomon, Stephen; Zhang, Jiangfeng; Carr, Zhanat

    2017-01-01

    Following a radiological or nuclear emergency, first responders and the public may become internally contaminated with radioactive materials, as demonstrated during the Goiânia, Chernobyl and Fukushima accidents. Timely monitoring of the affected populations for potential internal contamination, assessment of radiation dose and the provision of necessary medical treatment are required to minimize the health risks from the contamination. This paper summarizes the guidelines and tools that have been developed, and identifies the gaps and priorities for future projects. PMID:27521210

  18. Overgrowth.

    PubMed

    Verge, Charles F; Mowat, David

    2010-06-01

    Overgrowth presenting at birth requires blood glucose monitoring while a cause is sought. Among older children presenting with tall stature, common causes such as familial tall stature and simple obesity must be distinguished from rarer endocrine and genetic causes. Several genetic overgrowth syndromes carry increased risk of malignancy and regular screening is recommended. The use of high-dose oestrogen or testosterone in an attempt to limit final stature has limited efficacy and carries a significant risk of side effects. Endocrine and genetic assessment ought to be considered for cases of unexplained overgrowth.

  19. Real-time measurement and monitoring of absorbed dose for electron beams

    NASA Astrophysics Data System (ADS)

    Korenev, Sergey; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon

    2004-09-01

    The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators.

  20. USING THE HERMITE POLYNOMIALS IN RADIOLOGICAL MONITORING NETWORKS.

    PubMed

    Benito, G; Sáez, J C; Blázquez, J B; Quiñones, J

    2018-03-15

    The most interesting events in Radiological Monitoring Network correspond to higher values of H*(10). The higher doses cause skewness in the probability density function (PDF) of the records, which there are not Gaussian anymore. Within this work the probability of having a dose >2 standard deviations is proposed as surveillance of higher doses. Such probability is estimated by using the Hermite polynomials for reconstructing the PDF. The result is that the probability is ~6 ± 1%, much >2.5% corresponding to Gaussian PDFs, which may be of interest in the design of alarm level for higher doses.

  1. Pretransplant Tacrolimus Dose Requirements Predict Early Posttransplant Dose Requirements in Blood Group AB0-Incompatible Kidney Transplant Recipients.

    PubMed

    Shuker, Nauras; de Man, Femke M; de Weerd, Annelies E; van Agteren, Madelon; Weimar, Willem; Betjes, Michiel G H; van Gelder, Teun; Hesselink, Dennis A

    2016-04-01

    The aim of this study was to investigate whether pretransplant tacrolimus (Tac) dose requirements of patients scheduled to undergo living donor kidney transplantation correlate with posttransplantation dose requirements. The predictive value of Tac dose requirements (defined as the ratio of the Tac predose concentration, C0, divided by the total daily Tac dose, D) pretransplantation on this same parameter posttransplantation was assessed retrospectively in a cohort of 57 AB0-incompatible kidney transplant recipients. These patients started immunosuppressive therapy 14 days before transplant surgery. All patients were using a stable dose of glucocorticoids and were at steady-state Tac exposure before transplantation. Tac dose requirements immediately before transplantation (C0/Dbefore) explained 63% of the Tac dose requirements on day 3 after transplantation: r = 0.633 [F (1, 44) = 75.97, P < 0.01]. No other clinical and demographic variables predicted Tac dose requirements early after transplantation. Steady-state Tac dose requirement before transplantation largely predicted posttransplantation Tac dose requirements in AB0-incompatible kidney transplant recipients. The importance of this finding is that the posttransplantation Tac dose can be individualized based on a patient's pretransplantation Tac concentration/dose ratio. Pretransplant Tac phenotyping therefore has the potential to improve transplantation outcomes.

  2. Nevada Test Site annual site environmental report for calendar year 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, S.C.; Townsend, Y.E.

    1997-10-01

    Monitoring and surveillance on and around the Nevada Test Site (NTS) by US Department of Energy (DOE) contractors and NTS user organizations during 1996 indicated that operations on the NTS were conducted in compliance with applicable DOE, state, and federal regulations and guidelines. All discharges of radioactive liquids remained onsite in containment ponds, and there was no indication of potential migration of radioactivity to the offsite area through groundwater. Surveillance around the NTS indicated that airborne radioactivity from diffusion, evaporation of liquid effluents, or resuspension of soil was not detectable offsite, and exposure above background to members of the offsitemore » population was not measured by the offsite monitoring program. Using the US Environmental Protection Agency`s (EPA) Clean Air Package 1988 (CAP88)PC model and NTS radionuclide emissions and environmental monitoring data, the calculated effective dose equivalent (EDE) to the maximally exposed individual offsite would have been 0.11 mrem. This value is less than 2 percent of the federal dose limit prescribed for radionuclide air emissions. Any person receiving this dose would also have received 144 mrem from natural background radiation. There were no nonradiological releases to the offsite area. Hazardous wastes were shipped offsite to approved disposal facilities. Compliance with the various regulations stemming from the National Environmental Policy Act (NEPA) is being achieved and, where mandated, permits for air and water effluents and waste management have been obtained from the appropriate agencies. Cooperation with other agencies has resulted in seven different consent orders and agreements. Support facilities at off-NTS locations have complied with the requirements of air quality permits and state or local wastewater discharge and hazardous waste permits as mandated for each location.« less

  3. Adaptation and evaluation of the bottle assay for monitoring insecticide resistance in disease vector mosquitoes in the Peruvian Amazon

    PubMed Central

    Zamora Perea, Elvira; Balta León, Rosario; Palomino Salcedo, Miriam; Brogdon, William G; Devine, Gregor J

    2009-01-01

    Background The purpose of this study was to establish whether the "bottle assay", a tool for monitoring insecticide resistance in mosquitoes, can complement and augment the capabilities of the established WHO assay, particularly in resource-poor, logistically challenging environments. Methods Laboratory reared Aedes aegypti and field collected Anopheles darlingi and Anopheles albimanus were used to assess the suitability of locally sourced solvents and formulated insecticides for use with the bottle assay. Using these adapted protocols, the ability of the bottle assay and the WHO assay to discriminate between deltamethrin-resistant Anopheles albimanus populations was compared. The diagnostic dose of deltamethrin that would identify resistance in currently susceptible populations of An. darlingi and Ae. aegypti was defined. The robustness of the bottle assay during a surveillance exercise in the Amazon was assessed. Results The bottle assay (using technical or formulated material) and the WHO assay were equally able to differentiate deltamethrin-resistant and susceptible An. albimanus populations. A diagnostic dose of 10 μg a.i./bottle was identified as the most sensitive discriminating dose for characterizing resistance in An. darlingi and Ae. aegypti. Treated bottles, prepared using locally sourced solvents and insecticide formulations, can be stored for > 14 days and used three times. Bottles can be stored and transported under local conditions and field-assays can be completed in a single evening. Conclusion The flexible and portable nature of the bottle assay and the ready availability of its components make it a potentially robust and useful tool for monitoring insecticide resistance and efficacy in remote areas that require minimal cost tools. PMID:19728871

  4. Better retention of Malaysian opiate dependents treated with high dose methadone in methadone maintenance therapy

    PubMed Central

    2010-01-01

    Background Methadone is a synthetic opiate mu receptor agonist that is widely used to substitute for illicit opiates in the management of opiate dependence. It helps prevent opiate users from injecting and sharing needles which are vehicles for the spread of HIV and other blood borne viruses. This study has the objective of determining the utility of daily methadone dose to predict retention rates and re-injecting behaviour among opiate dependents. Methods Subjects comprised opiate dependent individuals who met study criteria. They took methadone based on the Malaysian guidelines and were monitored according to the study protocols. At six months, data was collected for analyses. The sensitivity and specificity daily methadone doses to predict retention rates and re-injecting behaviour were evaluated. Results Sixty-four patients volunteered to participate but only 35 (54.69%) remained active and 29 (45.31%) were inactive at 6 months of treatment. Higher doses were significantly correlated with retention rate (p < 0.0001) and re-injecting behaviour (p < 0.001). Of those retained, 80.0% were on 80 mg or more methadone per day doses with 20.0% on receiving 40 mg -79 mg. Conclusions We concluded that a daily dose of at least 40 mg was required to retain patients in treatment and to prevent re-injecting behaviour. A dose of at least 80 mg per day was associated with best results. PMID:21167035

  5. Thermoluminescence dosimetry and its applications in medicine--Part 2: History and applications.

    PubMed

    Kron, T

    1995-03-01

    Thermoluminescence dosimetry (TLD) has been available for dosimetry of ionising radiation for nearly 100 years. The variety of materials and their different physical forms allow the determination of different radiation qualities over a wide range of absorbed dose. This makes TL dosimeters useful in radiation protection where dose levels of microGy are monitored as well as in radiotherapy where doses up to several Gray are to be measured. The major advantages of TL detectors are their small physical size and that no cables or auxiliary equipment is required during the dose assessment. Therefore TLD is a good method for point dose measurements in phantoms as well as for in vivo dosimetry on patients during radiotherapy treatment. As an integrative dosimetric technique, it can be applied to personal dosimetry and it lends itself to the determination of dose distributions due to multiple or moving radiation sources (e.g. conformal and dynamic radiotherapy, computed tomography). In addition, TL dosimeters are easy to transport, and they can be mailed. This makes them well suited for intercomparison of doses delivered in different institutions. The present article aims at describing the various applications TLD has found in medicine by taking into consideration the physics and practice of TLD measurements which have been discussed in the first part of this review (Australas. Phys. Eng. Sci. Med. 17: 175-199, 1994).

  6. Efficacy and optimal dose of daily polyethylene glycol 3350 for treatment of constipation and encopresis in children.

    PubMed

    Pashankar, D S; Bishop, W P

    2001-09-01

    To determine efficacy, safety, and optimal dose of a laxative, polyethylene glycol (PEG) 3350, in children with chronic constipation. Children with chronic constipation (n = 24) were treated with PEG for 8 weeks at an initial dose of 1 g/kg/d. The dose was adjusted every 3 days as required to achieve 2 soft stools per day. A diary was kept to monitor dose, stool frequency and consistency, soiling, and other symptoms. Stool consistency was rated from 1 (hard) to 5 (watery). Subjects were examined for fecal retention. The Student t test and the Fisher exact test were used for data analysis. All 20 children who completed the study found PEG to be palatable and were satisfied with the treatment. There were no significant adverse effects. Weekly stool frequency increased from 2.3 +/- 0.4 to 16.9 +/- 1.6 (P <.0001) during treatment and stool consistency from 1.2 +/- 0.1 to 3.3 +/- 0.1 (P <.0001). In 9 children with soiling, weekly soiling events declined from 10.0 +/- 2.4 to 1.3 +/- 0.7 (P =.003). The mean effective dose was 0.84 g/kg/d (range, 0.27-1.42 g/kg/d). Daily administration of PEG at a mean dose of 0.8 g/kg is an effective, safe, and palatable treatment for constipation.

  7. FZUImageReg: A toolbox for medical image registration and dose fusion in cervical cancer radiotherapy

    PubMed Central

    Bai, Penggang; Du, Min; Ni, Xiaolei; Ke, Dongzhong; Tong, Tong

    2017-01-01

    The combination external-beam radiotherapy and high-dose-rate brachytherapy is a standard form of treatment for patients with locally advanced uterine cervical cancer. Personalized radiotherapy in cervical cancer requires efficient and accurate dose planning and assessment across these types of treatment. To achieve radiation dose assessment, accurate mapping of the dose distribution from HDR-BT onto EBRT is extremely important. However, few systems can achieve robust dose fusion and determine the accumulated dose distribution during the entire course of treatment. We have therefore developed a toolbox (FZUImageReg), which is a user-friendly dose fusion system based on hybrid image registration for radiation dose assessment in cervical cancer radiotherapy. The main part of the software consists of a collection of medical image registration algorithms and a modular design with a user-friendly interface, which allows users to quickly configure, test, monitor, and compare different registration methods for a specific application. Owing to the large deformation, the direct application of conventional state-of-the-art image registration methods is not sufficient for the accurate alignment of EBRT and HDR-BT images. To solve this problem, a multi-phase non-rigid registration method using local landmark-based free-form deformation is proposed for locally large deformation between EBRT and HDR-BT images, followed by intensity-based free-form deformation. With the transformation, the software also provides a dose mapping function according to the deformation field. The total dose distribution during the entire course of treatment can then be presented. Experimental results clearly show that the proposed system can achieve accurate registration between EBRT and HDR-BT images and provide radiation dose warping and fusion results for dose assessment in cervical cancer radiotherapy in terms of high accuracy and efficiency. PMID:28388623

  8. Modeling low-dose mortality and disease incubation period of inhalational anthrax in the rabbit.

    PubMed

    Gutting, Bradford W; Marchette, David; Sherwood, Robert; Andrews, George A; Director-Myska, Alison; Channel, Stephen R; Wolfe, Daniel; Berger, Alan E; Mackie, Ryan S; Watson, Brent J; Rukhin, Andrey

    2013-07-21

    There is a need to advance our ability to conduct credible human risk assessments for inhalational anthrax associated with exposure to a low number of bacteria. Combining animal data with computational models of disease will be central in the low-dose and cross-species extrapolations required in achieving this goal. The objective of the current work was to apply and advance the competing risks (CR) computational model of inhalational anthrax where data was collected from NZW rabbits exposed to aerosols of Ames strain Bacillus anthracis. An initial aim was to parameterize the CR model using high-dose rabbit data and then conduct a low-dose extrapolation. The CR low-dose attack rate was then compared against known low-dose rabbit data as well as the low-dose curve obtained when the entire rabbit dose-response data set was fitted to an exponential dose-response (EDR) model. The CR model predictions demonstrated excellent agreement with actual low-dose rabbit data. We next used a modified CR model (MCR) to examine disease incubation period (the time to reach a fever >40 °C). The MCR model predicted a germination period of 14.5h following exposure to a low spore dose, which was confirmed by monitoring spore germination in the rabbit lung using PCR, and predicted a low-dose disease incubation period in the rabbit between 14.7 and 16.8 days. Overall, the CR and MCR model appeared to describe rabbit inhalational anthrax well. These results are discussed in the context of conducting laboratory studies in other relevant animal models, combining the CR/MCR model with other computation models of inhalational anthrax, and using the resulting information towards extrapolating a low-dose response prediction for man. Published by Elsevier Ltd.

  9. Evaluation of an iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose.

    PubMed

    Aurumskjöld, Marie-Louise; Söderberg, Marcus; Stålhammar, Fredrik; von Steyern, Kristina Vult; Tingberg, Anders; Ydström, Kristina

    2018-06-01

    Background In pediatric patients, computed tomography (CT) is important in the medical chain of diagnosing and monitoring various diseases. Because children are more radiosensitive than adults, they require minimal radiation exposure. One way to achieve this goal is to implement new technical solutions, like iterative reconstruction. Purpose To evaluate the potential of a new, iterative, model-based method for reconstructing (IMR) pediatric abdominal CT at a low radiation dose and determine whether it maintains or improves image quality, compared to the current reconstruction method. Material and Methods Forty pediatric patients underwent abdominal CT. Twenty patients were examined with the standard dose settings and 20 patients were examined with a 32% lower radiation dose. Images from the standard examination were reconstructed with a hybrid iterative reconstruction method (iDose 4 ), and images from the low-dose examinations were reconstructed with both iDose 4 and IMR. Image quality was evaluated subjectively by three observers, according to modified EU image quality criteria, and evaluated objectively based on the noise observed in liver images. Results Visual grading characteristics analyses showed no difference in image quality between the standard dose examination reconstructed with iDose 4 and the low dose examination reconstructed with IMR. IMR showed lower image noise in the liver compared to iDose 4 images. Inter- and intra-observer variance was low: the intraclass coefficient was 0.66 (95% confidence interval = 0.60-0.71) for the three observers. Conclusion IMR provided image quality equivalent or superior to the standard iDose 4 method for evaluating pediatric abdominal CT, even with a 32% dose reduction.

  10. Lawrence Livermore National Laboratory Environmental Report 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosene, Crystal

    The purposes of the Environmental Report 2016 are to record LLNL’s compliance with environmental standards and requirements, describe LLNL’s environmental protection and remediation programs, and present the results of environmental monitoring. Specifically, the report discusses LLNL’s EMS; describes significant accomplishments in pollution prevention; presents the results of air, water, vegetation, and foodstuff monitoring; reports radiological doses from LLNL operations; summarizes LLNL’s activities involving special status wildlife, plants, and habitats; and describes the progress LLNL has made in remediating groundwater contamination. Environmental monitoring at LLNL, including analysis of samples and data, is conducted according to documented standard operating procedures. Duplicate samplesmore » are collected and analytical results are reviewed and compared to internal acceptance standards. This report is prepared for DOE by LLNL’s Environmental Functional Area (EFA). Submittal of the report satisfies requirements under DOE Order 231.1B, “Environment, Safety and Health Reporting,” and DOE Order 458.1, “Radiation Protection of the Public and Environment.” The report is distributed in electronic form and is available to the public at https://saer.llnl.gov/, the website for the LLNL annual environmental report. Previous LLNL annual environmental reports beginning with 1994 are also on the website.« less

  11. Warfarin Dosing Algorithms Underpredict Dose Requirements in Patients Requiring ≥7 mg Daily: A Systematic Review and Meta-analysis.

    PubMed

    Saffian, S M; Duffull, S B; Wright, Dfb

    2017-08-01

    There is preliminary evidence to suggest that some published warfarin dosing algorithms produce biased maintenance dose predictions in patients who require higher than average doses. We conducted a meta-analysis of warfarin dosing algorithms to determine if there exists a systematic under- or overprediction of dose requirements for patients requiring ≥7 mg/day across published algorithms. Medline and Embase databases were searched up to September 2015. We quantified the proportion of over- and underpredicted doses in patients whose observed maintenance dose was ≥7 mg/day. The meta-analysis included 47 evaluations of 22 different warfarin dosing algorithms from 16 studies. The meta-analysis included data from 1,492 patients who required warfarin doses of ≥7 mg/day. All 22 algorithms were found to underpredict warfarin dosing requirements in patients who required ≥7 mg/day by an average of 2.3 mg/day with a pooled estimate of underpredicted doses of 92.3% (95% confidence interval 90.3-94.1, I 2 = 24%). © 2017 American Society for Clinical Pharmacology and Therapeutics.

  12. High sensitivity charge amplifier for ion beam uniformity monitor

    DOEpatents

    Johnson, Gary W.

    2001-01-01

    An ion beam uniformity monitor for very low beam currents using a high-sensitivity charge amplifier with bias compensation. The ion beam monitor is used to assess the uniformity of a raster-scanned ion beam, such as used in an ion implanter, and utilizes four Faraday cups placed in the geometric corners of the target area. Current from each cup is integrated with respect to time, thus measuring accumulated dose, or charge, in Coulombs. By comparing the dose at each corner, a qualitative assessment of ion beam uniformity is made possible. With knowledge of the relative area of the Faraday cups, the ion flux and areal dose can also be obtained.

  13. 42 CFR 82.10 - Overview of the dose reconstruction process.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... doses using techniques discussed in § 82.16. Once the resulting data set is complete, NIOSH will.... Additionally, NIOSH may compile data, and information from NIOSH records that may contribute to the dose... which dose and exposure monitoring data is incomplete or insufficient for dose reconstruction. (h) NIOSH...

  14. 42 CFR 82.10 - Overview of the dose reconstruction process.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... doses using techniques discussed in § 82.16. Once the resulting data set is complete, NIOSH will.... Additionally, NIOSH may compile data, and information from NIOSH records that may contribute to the dose... which dose and exposure monitoring data is incomplete or insufficient for dose reconstruction. (h) NIOSH...

  15. 42 CFR 82.10 - Overview of the dose reconstruction process.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... doses using techniques discussed in § 82.16. Once the resulting data set is complete, NIOSH will.... Additionally, NIOSH may compile data, and information from NIOSH records that may contribute to the dose... which dose and exposure monitoring data is incomplete or insufficient for dose reconstruction. (h) NIOSH...

  16. 42 CFR 82.10 - Overview of the dose reconstruction process.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... doses using techniques discussed in § 82.16. Once the resulting data set is complete, NIOSH will.... Additionally, NIOSH may compile data, and information from NIOSH records that may contribute to the dose... which dose and exposure monitoring data is incomplete or insufficient for dose reconstruction. (h) NIOSH...

  17. 42 CFR 82.10 - Overview of the dose reconstruction process.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... doses using techniques discussed in § 82.16. Once the resulting data set is complete, NIOSH will.... Additionally, NIOSH may compile data, and information from NIOSH records that may contribute to the dose... which dose and exposure monitoring data is incomplete or insufficient for dose reconstruction. (h) NIOSH...

  18. Prescribing patterns and the use of therapeutic drug monitoring of psychotropic medication in a psychiatric high-security unit.

    PubMed

    Castberg, Ingrid; Spigset, Olav

    2008-10-01

    The aim of this study was to investigate the use of psychotropic medication and therapeutic drug monitoring in a high-security psychiatric unit and to compare the doses and serum concentrations both with the recommended intervals and with the doses and serum concentrations in a control group. One hundred thirty-two patients were admitted in the period from January 2000 to December 2005. All available samples were used when comparing serum concentrations and doses with the recommended ranges. For the comparison of doses and serum concentration-to-dose (C:D) ratios with the control group only 1 sample from each patient was used. A total of 459 analyses of 27 different drugs in samples from 8 women and 73 men were included. The median number of therapeutic drug monitoring analyses per patient was 4 (range 1-29). Thirty-seven of the 81 patients (46%) used 2 or more antipsychotics at the same time. Clozapine, lamotrigine, olanzapine, quetiapine, ziprasidone, and zuclopenthixol were often given in doses above the recommended. The serum levels were frequently above those recommended for clozapine, olanzapine, quetiapine, risperidone, ziprasidone, and zuclopenthixol. The serum levels were significantly higher in the study group than in the control group for clozapine, lamotrigine, quetiapine, and zuclopenthixol. The given dose was significantly higher in the study group than in the control group for clozapine, lamotrigine and zuclopenthixol. The C:D ratio was significantly lower in the study group than in the control group for olanzapine but higher for quetiapine. The non-evidence based practice of high-dose polypharmacy with several antipsychotics is widely used in this unit. The use of higher doses in the study group than in the control group was not due to differences in metabolism or adherence to treatment between the 2 groups. The frequent use of therapeutic drug monitoring did not seem to have a great impact on the prescribed doses.

  19. An automated dose tracking system for adaptive radiation therapy.

    PubMed

    Liu, Chang; Kim, Jinkoo; Kumarasiri, Akila; Mayyas, Essa; Brown, Stephen L; Wen, Ning; Siddiqui, Farzan; Chetty, Indrin J

    2018-02-01

    The implementation of adaptive radiation therapy (ART) into routine clinical practice is technically challenging and requires significant resources to perform and validate each process step. The objective of this report is to identify the key components of ART, to illustrate how a specific automated procedure improves efficiency, and to facilitate the routine clinical application of ART. Data was used from patient images, exported from a clinical database and converted to an intermediate format for point-wise dose tracking and accumulation. The process was automated using in-house developed software containing three modularized components: an ART engine, user interactive tools, and integration tools. The ART engine conducts computing tasks using the following modules: data importing, image pre-processing, dose mapping, dose accumulation, and reporting. In addition, custom graphical user interfaces (GUIs) were developed to allow user interaction with select processes such as deformable image registration (DIR). A commercial scripting application programming interface was used to incorporate automated dose calculation for application in routine treatment planning. Each module was considered an independent program, written in C++or C#, running in a distributed Windows environment, scheduled and monitored by integration tools. The automated tracking system was retrospectively evaluated for 20 patients with prostate cancer and 96 patients with head and neck cancer, under institutional review board (IRB) approval. In addition, the system was evaluated prospectively using 4 patients with head and neck cancer. Altogether 780 prostate dose fractions and 2586 head and neck cancer dose fractions went processed, including DIR and dose mapping. On average, daily cumulative dose was computed in 3 h and the manual work was limited to 13 min per case with approximately 10% of cases requiring an additional 10 min for image registration refinement. An efficient and convenient dose tracking system for ART in the clinical setting is presented. The software and automated processes were rigorously evaluated and validated using patient image datasets. Automation of the various procedures has improved efficiency significantly, allowing for the routine clinical application of ART for improving radiation therapy effectiveness. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Do fungi need to be included within environmental radiation protection assessment models?

    PubMed

    Guillén, J; Baeza, A; Beresford, N A; Wood, M D

    2017-09-01

    Fungi are used as biomonitors of forest ecosystems, having comparatively high uptakes of anthropogenic and naturally occurring radionuclides. However, whilst they are known to accumulate radionuclides they are not typically considered in radiological assessment tools for environmental (non-human biota) assessment. In this paper the total dose rate to fungi is estimated using the ERICA Tool, assuming different fruiting body geometries, a single ellipsoid and more complex geometries considering the different components of the fruit body and their differing radionuclide contents based upon measurement data. Anthropogenic and naturally occurring radionuclide concentrations from the Mediterranean ecosystem (Spain) were used in this assessment. The total estimated weighted dose rate was in the range 0.31-3.4 μGy/h (5 th -95 th percentile), similar to natural exposure rates reported for other wild groups. The total estimated dose was dominated by internal exposure, especially from 226 Ra and 210 Po. Differences in dose rate between complex geometries and a simple ellipsoid model were negligible. Therefore, the simple ellipsoid model is recommended to assess dose rates to fungal fruiting bodies. Fungal mycelium was also modelled assuming a long filament. Using these geometries, assessments for fungal fruiting bodies and mycelium under different scenarios (post-accident, planned release and existing exposure) were conducted, each being based on available monitoring data. The estimated total dose rate in each case was below the ERICA screening benchmark dose, except for the example post-accident existing exposure scenario (the Chernobyl Exclusion Zone) for which a dose rate in excess of 35 μGy/h was estimated for the fruiting body. Estimated mycelium dose rate in this post-accident existing exposure scenario was close to the 400 μGy/h benchmark for plants, although fungi are generally considered to be less radiosensitive than plants. Further research on appropriate mycelium geometries and their radionuclide content is required. Based on the assessments presented in this paper, there is no need to recommend that fungi should be added to the existing assessment tools and frameworks; if required some tools allow a geometry representing fungi to be created and used within a dose assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Magnesium in obstetric anesthesia and intensive care.

    PubMed

    Kutlesic, Marija S; Kutlesic, Ranko M; Mostic-Ilic, Tatjana

    2017-02-01

    Magnesium, one of the essential elements in the human body, has numerous favorable effects that offer a variety of possibilities for its use in obstetric anesthesia and intensive care. Administered as a single intravenous bolus dose or a bolus followed by continuous infusion during surgery, magnesium attenuates stress response to endotracheal intubation, and reduces intraoperative anesthetic and postoperative analgesic requirements, while at the same time preserving favorable hemodynamics. Applied as part of an intrathecal or epidural anesthetic mixture, magnesium prolongs the duration of anesthesia and diminishes total postoperative analgesic consumption with no adverse maternal or neonatal effects. In obstetric intensive care, magnesium represents a first-choice medication in the treatment and prevention of eclamptic seizures. If used in recommended doses with close monitoring, magnesium is a safe and effective medication.

  2. Niagara Falls Storage Site annual site environmental monitoring report. Calendar year 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-04-01

    During 1985, an environmental monitoring program was continued at the Niagara Falls Storage Site (NFSS), a United States Department of Energy (DOE) surplus facility located in Niagara County, New York, presently used for the interim storage of low-level radioactive residues and contaminated soils and rubble. The monitoring program is being conducted by Bechtel National, Inc. Monitoring results show that the NFSS is in compliance with DOE concentration guides and radiation protection standards. Derived Concentration Guides (DCGs) represent the concentrations of radionuclides in air or water that would limit the radiation dose to 100 mrem/yr. The applicable limits have been revisedmore » since the 1984 environmental monitoring report was published. The limits applied in 1984 were based on a radiation protection standard of 500 mrem/yr; the limits applied for the 1985 are based on a standard of 100 mrem/yr. To determine whether the site is in compliance with DOE standards, environmental measurements are expressed as percentages of the applicable DCG, while the calculated doses to the public are expressed as percentages of the applicable radiation protection standard. The monitoring program measured radon gas concentrations in air; uranium and radium concentrations in surface water, groundwater, and sediments; and external gamma dose rates. Environmental samples collected were analyzed to determine compliance with applicable standards. Potential radiation doses to the public were also calculated.« less

  3. An algorithm for intelligent sorting of CT-related dose parameters.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Boonn, William W; Kim, Woojin

    2012-02-01

    Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)--an indirect estimate of radiation dose--requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, "arterial" could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  4. Dosimetry during intramedullary nailing of the tibia

    PubMed Central

    2009-01-01

    Background Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. Patients and methods 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. Results The mean operation time was 101 (48–240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy·cm2. The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Interpretation Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique. PMID:19916691

  5. An algorithm for intelligent sorting of CT-related dose parameters

    NASA Astrophysics Data System (ADS)

    Cook, Tessa S.; Zimmerman, Stefan L.; Steingal, Scott; Boonn, William W.; Kim, Woojin

    2011-03-01

    Imaging centers nationwide are seeking innovative means to record and monitor CT-related radiation dose in light of multiple instances of patient over-exposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose-length product (DLP)-an indirect estimate of radiation dose-requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, Arterial could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired, and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  6. UV dose measurements of photosensitive dermatosis patients by polycrystalline GaN-based portable self-data-acquisition UV monitors.

    PubMed

    Yagi, Shigeru; Iwanaga, Takeshi; Kojima, Hiroshi; Shoji, Yoshio; Suzuki, Seiji; Seno, Kunihiro; Mori, Hisayoshi; Tokura, Yoshiki; Takigawa, Masahiro; Moriwaki, Shin-Ichi

    2002-12-01

    We have developed a UV monitor with polycrystalline (poly-) gallium nitride (GaN) UV sensors and evaluated its performance from the viewpoint of its effectiveness for use with photosensitive dermatosis patients. The poly-GaN UV sensor is sensitive to UV light from 280 to 410 nm even without optical filters. The UV monitor is a portable self-data-acquisition instrument with a minimum detection level (defined as average UV intensity over 290 to 400 nm) of 2 microW/cm2 and can store UV dose data for 128 days. It allows easy measurement of four orders of magnitude of ambient UV intensity and dose from indoor light to direct solar radiation in summer. Trial use of the UV monitor by five xeroderma pigmentosum patients started in June 2000 and was carried out for 1 year. It was demonstrated that the UV monitor was useful in improving their quality of life.

  7. The future prospects of pharmacogenetics in oral anticoagulation therapy

    PubMed Central

    Kamali, Farhad; Pirmohamed, Munir

    2006-01-01

    Coumarins are the mainstay of oral anticoagulation for the treatment and prophylaxis of thromboembolic disorders. They have a narrow therapeutic index and regular monitoring is therefore required to avoid serious adverse effects. There is wide interindividual variability in dosage requirements, which makes anticoagulation response unpredictable. Current dosing titrations are haphazard and inconvenient and poor initial control leads to morbidity, and occasional mortality, because of bleeding and further thromboembolism. Recent discoveries have helped to characterize the factors that contribute to the interindividual variability in responses to coumarins. Patient and environmental factors that affect anticoagulation response to coumarins include age, body size, dietary vitamin K status, concurrent disease and drug interactions. More recently, single nucleotide polymorphisms in the 2C9 isoform of cytochrome P450 (CYP2C9) and vitamin K epoxide reductase (VKOR) have been shown to make significant contributions to the variability in coumarin dosage requirements. Polymorphisms in other genes that mediate the actions of coumarins may also contribute to this variability. Racial and cultural differences influence dosage requirements, which can be explained, at least in part, by genetic and dietary factors. Incorporation of genetic and environmental factors could help in the prediction of more individualized loading and maintenance doses for safer anticoagulation therapy. PMID:16722840

  8. Wayne Interim Storage Site environmental report for calendar year 1992, 868 Black Oak Ridge Road, Wayne, New Jersey. Formerly Utilized Sites Remedial Action Program (FUSRAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-05-01

    This report describes the environmental surveillance program at the Wayne Interim Storage Site (WISS) and provides the results for 1992. The fenced, site, 32 km (20 mi) northwest of Newark, New Jersey, was used between 1948 and 1971 for commercial processing of monazite sand to separate natural radioisotopes - predominantly thorium. Environmental surveillance of WISS began in 1984 in accordance with Department of Energy (DOE) Order 5400.1 when Congress added the site to DOE`s Formerly Utilized Sites Remedial Action Program (FUSRAP). The environmental surveillance program at WISS includes sampling networks for radon and thoron in air; external gamma radiation exposure;more » radium-226, radium-228, thorium-230, thorium-232, total uranium, and several chemicals in surface water and sediment; and total uranium, radium-226, radium-228, thorium-230, thorium-232, and organic and inorganic chemicals in groundwater. Monitoring results are compared with applicable Environmental Protection Agency (EPA) and state standards, DOE derived concentration guides (DCGs), dose limits, and other DOE requirements. This monitoring program assists in fulfilling the DOE policy of measuring and monitoring effluents from DOE activities and calculating hypothetical doses. Results for environmental surveillance in 1992 show that the concentrations of all radioactive and most chemical contaminants were below applicable standards.« less

  9. Repeated sugammadex reversal of muscle relaxation during lumbar spine surgery with intraoperative neurophysiological multimodal monitoring.

    PubMed

    Errando, C L; Blanco, T; Díaz-Cambronero, Ó

    2016-11-01

    Intraoperative neurophysiological monitoring during spine surgery is usually acomplished avoiding muscle relaxants. A case of intraoperative sugammadex partial reversal of the neuromuscular blockade allowing adequate monitoring during spine surgery is presented. A 38 year-old man was scheduled for discectomy and vertebral arthrodesis throughout anterior and posterior approaches. Anesthesia consisted of total intravenous anesthesia plus rocuronium. Intraoperatively monitoring was needed, and the muscle relaxant reverted twice with low dose sugammadex in order to obtain adequate responses. The doses of sugammadex used were conservatively selected (0.1mg/kg boluses increases, total dose needed 0.4mg/kg). Both motor evoqued potentials, and electromyographic responses were deemed adequate by the neurophysiologist. If muscle relaxation was needed in the context described, this approach could be useful to prevent neurological sequelae. This is the first study using very low dose sugammadex to reverse rocuronium intraoperatively and to re-establish the neuromuscular blockade. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Palliative sedation at home for terminally ill children with cancer.

    PubMed

    Korzeniewska-Eksterowicz, Aleksandra; Przysło, Łukasz; Fendler, Wojciech; Stolarska, Małgorzata; Młynarski, Wojciech

    2014-11-01

    The presence of symptoms that are difficult to control always requires adjustment of treatment, and palliative sedation (PS) should be considered. We analyzed our experience in conducting PS at home for terminally ill children with cancer during a seven-year period. We performed a retrospective analysis of medical records of children with cancer treated at home between the years 2005 and 2011. We analyzed the data of 42 cancer patients (18% of all patients); in 21 cases, PS was initiated (solid tumors n = 11, brain tumors [5], bone tumors [4], leukemia [1]). Sedation was introduced because of pain (n = 13), dyspnea (9), anxiety (5), or two of those symptoms (6). The main drug used for sedation was midazolam; all patients received morphine. There were no significant differences in the dose of morphine or midazolam depending on the patient's sex; age was correlated with an increase of midazolam dose (R = 0.68; P = 0.005). Duration of sedation (R = 0.61; P = 0.003) and its later initiation (R = 0.43; P = 0.05) were correlated with an increase of the morphine dose. All patients received adjuvant treatment; in patients who required a morphine dose increase, metoclopramide was used more often (P = 0.0002). Patients did not experience any adverse reactions. Later introduction of sedation was associated with a marginally higher number of intervention visits and a significantly higher number of planned visits (R = 0.53; P = 0.013). Sedation may be safely used at home. It requires close monitoring and full cooperation between the family and hospice team. Because of the limited data on home PS in pediatric populations, further studies are needed. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  11. Characteristics and verification of a car-borne survey system for dose rates in air: KURAMA-II.

    PubMed

    Tsuda, S; Yoshida, T; Tsutsumi, M; Saito, K

    2015-01-01

    The car-borne survey system KURAMA-II, developed by the Kyoto University Research Reactor Institute, has been used for air dose rate mapping after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA-II consists of a CsI(Tl) scintillation detector, a GPS device, and a control device for data processing. The dose rates monitored by KURAMA-II are based on the G(E) function (spectrum-dose conversion operator), which can precisely calculate dose rates from measured pulse-height distribution even if the energy spectrum changes significantly. The characteristics of KURAMA-II have been investigated with particular consideration to the reliability of the calculated G(E) function, dose rate dependence, statistical fluctuation, angular dependence, and energy dependence. The results indicate that 100 units of KURAMA-II systems have acceptable quality for mass monitoring of dose rates in the environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Effects of alfaxalone administered intravenously to healthy yearling loggerhead sea turtles (Caretta caretta) at three different doses.

    PubMed

    Phillips, Brianne E; Posner, Lysa P; Lewbart, Gregory A; Christiansen, Emily F; Harms, Craig A

    2017-04-15

    OBJECTIVE To compare physiologic and anesthetic effects of alfaxalone administered IV to yearling loggerhead sea turtles (Caretta caretta) at 3 different doses. DESIGN Randomized crossover study. ANIMALS 9 healthy yearling loggerhead sea turtles. PROCEDURES Animals received each of 3 doses of alfaxalone (3 mg/kg [1.4 mg/lb], 5 mg/kg [2.3 mg/lb], or 10 mg/kg [4.5 mg/lb]) administered IV in randomly assigned order, with a minimum 7-day washout period between doses. Endotracheal intubation was attempted following anesthetic induction, and heart rate, sedation depth, cloacal temperature, and respirations were monitored. Times to first effect, induction, first voluntary muscle movement, first respiration, and recovery were recorded. Venous blood gas analysis was performed at 0 and 30 minutes. Assisted ventilation was performed if apnea persisted 30 minutes following induction. RESULTS Median anesthetic induction time for all 3 doses was 2 minutes. Endotracheal intubation was accomplished in all turtles following induction. Heart rate significantly increased after the 3- and 5-mg/kg doses were administered. Median intervals from alfaxalone administration to first spontaneous respiration were 16, 22, and 54 minutes for the 3-, 5-, and 10-mg/kg doses, respectively, and median intervals to recovery were 28, 46, and 90 minutes, respectively. Assisted ventilation was required for 1 turtle after receiving the 5-mg/kg dose and for 5 turtles after receiving the 10-mg/kg dose. The 10-mg/kg dose resulted in respiratory acidosis and marked hypoxemia at 30 minutes. CONCLUSIONS AND CLINICAL RELEVANCE IV alfaxalone administration to loggerhead sea turtles resulted in a rapid anesthetic induction and dose-dependent duration of sedation. Assisted ventilation is recommended if the 10 mg/kg dose is administered.

  13. Iron dosing in kidney disease: inconsistency of evidence and clinical practice

    PubMed Central

    Gaweda, Adam E.; Ginzburg, Yelena Z.; Chait, Yossi; Germain, Michael J.; Aronoff, George R.; Rachmilewitz, Eliezer

    2015-01-01

    The management of anemia in patients with chronic kidney disease (CKD) is difficult. The availability of erythropoiesis-stimulating agents (ESAs) has increased treatment options for previously transfusion-requiring patients, but the recent evidence of ESA side effects has prompted the search for complementary or alternative approaches. Next to ESA, parenteral iron supplementation is the second main form of anemia treatment. However, as of now, no systematic approach has been proposed to balance the concurrent administration of both agents according to individual patient's needs. Furthermore, the potential risks of excessive iron dosing remain a topic of controversy. How, when and whether to monitor CKD patients for potential iron overload remain to be elucidated. This review addresses the question of risk and benefit of iron administration in CKD, highlights the evidence supporting current practice, provides an overview of standard and potential new markers of iron status and outlines a new pharmacometric approach to physiologically compatible individualized dosing of ESA and iron in CKD patients. PMID:24821751

  14. DOE 2011 occupational radiation exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2012-12-01

    The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2011 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protectionmore » of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. The occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site over the past five years.« less

  15. Satellite change detection of forest damage near the Chernobyl accident

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClellan, G.E.; Anno, G.H.

    1992-01-01

    A substantial amount of forest within a few kilometers of the Chernobyl nuclear reactor station was badly contaminated with radionuclides by the April 26, 1986, explosion and ensuing fire at reactor No. 4. Radiation doses to conifers in some areas were sufficient to cause discoloration of needles within a few weeks. Other areas, receiving smaller doses, showed foliage changes beginning 6 months to a year later. Multispectral imagery available from Landsat sensors is especially suited for monitoring such changes in vegetation. A series of Landsat Thematic Mapper images was developed that span the 2 yr following the accident. Quantitative dosemore » estimation for the exposed conifers requires an objective change detection algorithm and knowledge of the dose-time response of conifers to ionizing radiation. Pacific-Sierra Research Corporation's Hyperscout{trademark} algorithm is based on an advanced, sensitive technique for change detection particularly suited for multispectral images. The Hyperscout algorithm has been used to assess radiation damage to the forested areas around the Chernobyl nuclear power plant.« less

  16. Compliance with occlusion therapy for childhood amblyopia.

    PubMed

    Wallace, Michael P; Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2013-09-17

    Explore compliance with occlusion treatment of amblyopia in the Monitored and Randomized Occlusion Treatment of Amblyopia Studies (MOTAS and ROTAS), using objective monitoring. Both studies had a three-phase protocol: initial assessment, refractive adaptation, and occlusion. In the occlusion phase, participants were instructed to dose for 6 hours/day (MOTAS) or randomized to 6 or 12 hour/day (ROTAS). Dose was monitored continuously using an occlusion dose monitor (ODM). One hundred and fifty-two patients (71 male, 81 female; 122 Caucasian, 30 non-Caucasian) of mean ± SD age 68 ± 18 months participated. Amblyopia was defined as an interocular acuity difference of at least 0.1 logMAR and was associated with anisometropia in 50, strabismus in 44, and both (mixed) in 58. Median duration of occlusion was 99 days (interquartile range 72 days). Mean compliance was 44%, mean proportion of days with no patch worn was 42%. Compliance was lower (39%) on weekends compared with weekdays (46%, P = 0.04), as was the likelihood of dosing at all (52% vs. 60%, P = 0.028). Compliance was lower when attendance was less frequent (P < 0.001) and with prolonged treatment duration (P < 0.001). Age, sex, amblyopia type, and severity were not associated with compliance. Mixture modeling suggested three subpopulations of patch day doses: less than 30 minutes; doses that achieve 30% to 80% compliance; and doses that achieve around 100% compliance. This study shows that compliance with patching treatment averages less than 50% and is influenced by several factors. A greater understanding of these influences should improve treatment outcome. (ClinicalTrials.gov number, NCT00274664).

  17. Monitoring of anesthetic depth during surgical correction of acquired valvular disorders: single center, randomized trial.

    PubMed

    Lenkin, Andrey I; Zaharov, Viktor I; Lenkin, Pavel I; Smetkin, Alexey A; Bjertnaes, Lars J; Kirov, Mikhail Y

    2014-04-01

    The authors' primary objective was to test the hypothesis that Cerebral State Index (CSI)-guided control of anesthetic depth might reduce the consumption of anesthetics and shorten the duration of ICU and hospital stays after surgical correction of combined valve disorders. Single center, randomized trial. City Hospital Number 1 of Arkhangelsk, Russian Federation. Fifty adult patients with combined valve disorders requiring surgical correction. The patients were randomized into 2 groups. In the CSI group, anesthetic depth was monitored, and the rate of infusion of propofol was titrated to maintain the depth of anesthesia corresponding to a CSI of 40-60. In the control group, the depth of anesthesia was monitored clinically, and the dosage of propofol was administered according to the recommendations of the manufacturer. All patients received standard perioperative monitoring. Consumption of anesthetics and length of ICU and hospital stays were recorded. Preoperative patient characteristics did not differ significantly between the groups. In the CSI group, average intraoperative doses of midazolam and propofol were reduced by 41% and 19%, respectively (p<0.01). Maintenance of anesthesia guided by CSI shortened the time until fit for ICU discharge by 50% and reduced the lengths of ICU and postoperative hospital stays by 35% and 25%, respectively (p< 0.05). Monitoring of anesthetic depth reduces the requirements for midazolam and propofol, resulting in a faster recovery and a shorter postoperative ICU and hospital stay after surgical correction of combined valve disorders. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Error detection capability of a novel transmission detector: a validation study for online VMAT monitoring.

    PubMed

    Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes

    2017-09-01

    The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min -1 . Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from  -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean : R 2   =  0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.

  19. Error detection capability of a novel transmission detector: a validation study for online VMAT monitoring

    NASA Astrophysics Data System (ADS)

    Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes

    2017-09-01

    The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min-1. Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from  -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean: R 2  =  0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.

  20. Validation of a metered dose inhaler electronic monitoring device: implications for asthma clinical trial use.

    PubMed

    Pilcher, Janine; Holliday, Mark; Ebmeier, Stefan; McKinstry, Steve; Messaoudi, Fatiha; Weatherall, Mark; Beasley, Richard

    2016-01-01

    The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin monitor in recording Ventolin actuations. 20 SmartTouch Ventolin monitors were attached to Ventolin metered dose inhalers. Bench testing was performed over a 10-week period, to reflect the potential time frame between visits in a clinical trial. Inhaler actuations were recorded in a paper diary, which was compared with data uploaded from the monitors. 2560 actuations were performed during the 10-week study period. Monitor sensitivity for diary-recorded actuations was 99.9% with a lower 97.5% confidence bound of 99.7%. The positive predictive value for diary-recorded actuations was 100% with a 97.5% lower confidence bound of 99.9%. The SmartTouch Ventolin monitor is highly accurate in recording and retaining electronic data. It can be recommended for use in clinical trial settings in which training and quality control systems are incorporated into study protocols to ensure accurate data acquisition.

  1. Validation of a metered dose inhaler electronic monitoring device: implications for asthma clinical trial use

    PubMed Central

    Pilcher, Janine; Holliday, Mark; Ebmeier, Stefan; McKinstry, Steve; Messaoudi, Fatiha; Weatherall, Mark; Beasley, Richard

    2016-01-01

    Background The SmartTouch Ventolin monitor (Adherium, Auckland, New Zealand) is an electronic monitor for use with a Ventolin metered dose inhaler, which records the date and time of inhaler actuations. This technology has the potential to allow in-depth analysis of patterns of inhaler use in clinical trial settings. The aim of this study was to determine the accuracy of the SmartTouch Ventolin monitor in recording Ventolin actuations. Methods 20 SmartTouch Ventolin monitors were attached to Ventolin metered dose inhalers. Bench testing was performed over a 10-week period, to reflect the potential time frame between visits in a clinical trial. Inhaler actuations were recorded in a paper diary, which was compared with data uploaded from the monitors. Results 2560 actuations were performed during the 10-week study period. Monitor sensitivity for diary-recorded actuations was 99.9% with a lower 97.5% confidence bound of 99.7%. The positive predictive value for diary-recorded actuations was 100% with a 97.5% lower confidence bound of 99.9%. Conclusions The SmartTouch Ventolin monitor is highly accurate in recording and retaining electronic data. It can be recommended for use in clinical trial settings in which training and quality control systems are incorporated into study protocols to ensure accurate data acquisition. PMID:27026805

  2. Comparative analysis of radioecological monitoring dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sobolev, A.I.; Pol`skii, O.G.; Shanin, O.B.

    1995-03-01

    This paper describes comparative estimates of radiation doses measured by two types of thermoluminescence dosimeters and two types of background radiation radiometers. The dosimetry systems were tested by simultaneously recording background radiation and standard radiation sources at a radioactive waste storage facility. Statistical analysis of the measurement results is summarized. The maximum recorded exposure dose rate for the experiment was 19 microrads per hour. The DTK-2 dosimeter overestimated dose rates by 6 to 43% and the DTU-2 dosimeter underestimated dose rates by 7 to 21%. Both devices are recommended for radioecological monitoring in populated areas. 4 refs., 3 figs., 5more » tabs.« less

  3. Managing iron overload in patients with myelodysplastic syndromes with oral deferasirox therapy.

    PubMed

    Jabbour, Elias; Garcia-Manero, Guillermo; Taher, Ali; Kantarjian, Hagop M

    2009-05-01

    Patients with myelodysplastic syndromes (MDS) often require chronic RBC transfusions, which can lead to iron overload. Without adequate management, this may cause progressive damage to hepatic, endocrine, and cardiac organs, significantly affecting overall survival. Recent retrospective analyses have suggested that iron chelation provides a survival advantage in iron-overloaded patients with MDS who are given chelation therapy compared with those who are not. Nonetheless, it is evident that iron overload in many patients with MDS is not adequately managed. Clinical evaluation of the once-daily, oral iron chelator deferasirox in MDS populations has indicated that it provides dose-dependent reductions in body iron burden and is generally well tolerated, with a manageable safety profile in adult and pediatric patients. The most common treatment-related adverse events (AEs) included transient, mild-to-moderate gastrointestinal disturbances and skin rash, which rarely required drug discontinuation and resolved spontaneously in most cases. Adequate management of AEs and practical approaches such as patient education and counseling are necessary to ensure that patients remain compliant with therapy. Regular monitoring of serum ferritin levels is key to identifying patients who require iron chelation therapy, and to ensure maintenance of iron levels below the critical level of 1,000 microg/l. The flexible dosing regimen of deferasirox allows dose adjustments to be made in response to trends in serum ferritin, to changes in a patient's transfusional iron intake, and to the objectives of treatment, allowing the full benefit of transfusion therapy without the risks associated with iron overload.

  4. The DOPPS Practice Monitor for US dialysis care: trends through August 2011.

    PubMed

    Pisoni, Ronald L; Fuller, Douglas S; Bieber, Brian A; Gillespie, Brenda W; Robinson, Bruce M

    2012-07-01

    We have examined trends in hemodialysis practice from August 2010 to August 2011, a time frame spanning the implementation of the bundled PPS, a major ESA label change by the FDA, and announcements from CMS on the proposed and final rules for the first year of the Quality Incentive Program (QIP) plus the proposed rules for the second and third years of the QIP. Although many hemodialysis practices have remained stable during this 1-year time period, substantial changes have been seen. These include a decline in epoetin dose and hemoglobin levels, an increase in IV iron use and serum ferritin levels, and an increase in PTH levels. The rates of decline in hemoglobin and epoetin dosing levels were greatest in the 2 months after the ESA label change in June 2011. Trends in anemia care in ensuing months, with more follow-up time after the label change, will be of great interest. In view of declining hemoglobin levels, a mechanism for comprehensive monitoring of transfusion rates is warranted to understand this important aspect of care for hemodialysis patients. Regarding clinical outcomes, no trend in all-cause mortality has been evident during this 1-year time period. Additional follow-up is warranted to understand if findings reported here persist over time, and require confirmation with national data as these become available. Trends in clinical care may not necessarily affect patient outcomes, and careful evaluation is required to understand effects on patient outcomes.

  5. Australasian Society for Parenteral and Enteral Nutrition guidelines for supplementation of trace elements during parenteral nutrition.

    PubMed

    Osland, Emma J; Ali, Azmat; Isenring, Elizabeth; Ball, Patrick; Davis, Melvyn; Gillanders, Lyn

    2014-01-01

    This work represents the first part of a progressive review of AuSPEN's 1999 Guidelines for Provision of Micronutrient Supplementation in Adult Patients receiving Parenteral Nutrition, in recognition of the developments in the literature on this topic since that time. A systematic literature review was undertaken and recommendations were made based on the available evidence and with consideration to specific elements of the Australian and New Zealand practice environment. The strength of evidence underpinning each recommendation was assessed. External reviewers provided feedback on the guidelines using the AGREE II tool. Reduced doses of manganese, copper, chromium and molybdenum, and an increased dose of selenium are recommended when compared with the 1999 guidelines. Currently the composition of available multi-trace element formulations is recognised as an obstacle to aligning these guidelines with practice. A paucity of available literature and limitations with currently available methods of monitoring trace element status are acknowledged. The currently unknown clinical impact of changes to trace element contamination of parenteral solutions with contemporary practices highlights need for research and clinical vigilance in this area of nutrition support practice. Trace elements are essential and should be provided daily to patients receiving parenteral nutrition. Monitoring is generally only required in longer term parenteral nutrition, however should be determined on an individual basis. Industry is encouraged to modify existing multi-trace element solutions available in Australia and New Zealand to reflect changes in the literature outlined in these guidelines. Areas requiring research are highlighted.

  6. Dose-Finding Study of Omeprazole on Gastric pH in Neonates with Gastro-Esophageal Acid Reflux Using a Bayesian Sequential Approach.

    PubMed

    Kaguelidou, Florentia; Alberti, Corinne; Biran, Valerie; Bourdon, Olivier; Farnoux, Caroline; Zohar, Sarah; Jacqz-Aigrain, Evelyne

    2016-01-01

    Proton pump inhibitors are frequently administered on clinical symptoms in neonates but benefit remains controversial. Clinical trials validating omeprazole dosage in neonates are limited. The objective of this trial was to determine the minimum effective dose (MED) of omeprazole to treat pathological acid reflux in neonates using reflux index as surrogate marker. Double blind dose-finding trial with continual reassessment method of individual dose administration using a Bayesian approach, aiming to select drug dose as close as possible to the predefined target level of efficacy (with a credibility interval of 95%). Neonatal Intensive Care unit of the Robert Debré University Hospital in Paris, France. Neonates with a postmenstrual age ≥ 35 weeks and a pathologic 24-hour intra-esophageal pH monitoring defined by a reflux index ≥ 5% over 24 hours were considered for participation. Recruitment was stratified to 3 groups according to gestational age at birth. Five preselected doses of oral omeprazole from 1 to 3 mg/kg/day. Primary outcome, measured at 35 weeks postmenstrual age or more, was a reflux index <5% during the 24-h pH monitoring registered 72±24 hours after omeprazole initiation. Fifty-four neonates with a reflux index ranging from 5.06 to 27.7% were included. Median age was 37.5 days and median postmenstrual age was 36 weeks. In neonates born at less than 32 weeks of GA (n = 30), the MED was 2.5mg/kg/day with an estimated mean posterior probability of success of 97.7% (95% credibility interval: 90.3-99.7%). The MED was 1mg/kg/day for neonates born at more than 32 GA (n = 24). Omeprazole is extensively prescribed on clinical symptoms but efficacy is not demonstrated while safety concerns do exist. When treatment is required, the daily dose needs to be validated in preterm and term neonates. Optimal doses of omeprazole to increase gastric pH and decrease reflux index below 5% over 24 hours, determined using an adaptive Bayesian design differ among neonates. Both gestational and postnatal ages account for these differences but their differential impact on omeprazole doses remains to be determined.

  7. Levofloxacin dosing regimen in severely morbidly obese patients (BMI ≥40 kg/m(2)) should be guided by creatinine clearance estimates based on ideal body weight and optimized by therapeutic drug monitoring.

    PubMed

    Pai, Manjunath P; Cojutti, Piergiorgio; Pea, Federico

    2014-08-01

    Levofloxacin is a commonly prescribed antimicrobial where recommendations exist to reduce doses for renal impairment but not to increase doses for augmented renal function. Morbidly obese patients are increasing in prevalence, and represent a population that can have augmented renal function requiring higher-than-standard doses. The current investigation was performed to characterize the pharmacokinetics (PK) and evaluate the influence of alternate body size descriptors and renal function as predictors of levofloxacin clearance (CL) and the area under the curve over 24 h (AUC24). A database of patients undergoing levofloxacin therapeutic drug monitoring (TDM) were queried to identify patients ≥18 years of age with a body mass index ≥40 kg/m(2). A maximum a posteriori probability Bayesian approach using a two-compartment linear PK model was used to estimate individual PK parameters and AUC24. A total of 394 concentration-time data points (peaks and trough) from 68 patients between 98 and 250 kg were evaluated. The median (5th, 95th percentile) daily dose and AUC24 was 1,000 (250, 1,500) mg and 90.7 (44.4, 228) mg·h/L, respectively. Levofloxacin CL was significantly (p < 0.05) related to height but not weight. As a result, levofloxacin CL was best related (R (2) = 0.57) to creatinine CL (CLcr) estimated by the Cockcroft-Gault (CG) equation and ideal body weight (IBW) because IBW is a height transformation. An empiric four-category daily-dose regimen (500, 750, 1,000, 1,250 mg) stratified by CLcr (CG-IBW) is expected to have >90 % probability of achieving an AUC24 of 50-150 mg·h/L in morbidly obese patients. Subsequent application of TDM and integration with pathogen-specific information could then be applied to tailor the levofloxacin regimen. The proposed approach serves as a relevant alternative to the current fixed-dosing paradigm of levofloxacin in the morbidly obese.

  8. Dose assessment activities in the Republic of the Marshall Islands.

    PubMed

    Simon, S L; Graham, J C

    1996-10-01

    Dose assessments, both retrospective and prospective, comprise one important function of a radiological study commissioned by the Republic of the Marshall Islands (RMI) government in late 1989. Estimating past or future exposure requires the synthesis of information from historical data, results from a recently completed field monitoring program, laboratory measurements, and some experimental studies. Most of the activities in the RMI to date have emphasized a pragmatic rather than theoretical approach. In particular, most of the recent effort has been expended on conducting an independent radiological monitoring program to determine the degree of deposition and the geographical extent of weapons test fallout over the nation. Contamination levels on 70% of the land mass of the Marshall Islands were unknown prior to 1994. The environmental radioactivity data play an integral role in both retrospective and prospective assessments. One recent use of dose assessment has been to interpret environmental measurements of radioactivity into annual doses that might be expected at every atoll. A second use for dose assessment has been to determine compliance with a dose action level for the rehabilitation of Rongelap Island. Careful examination of exposure pathways relevant to the island lifestyle has been necessary to accommodate these purposes. Examples of specific issues studied include defining traditional island diets as well as current day variations, sources of drinking water, uses of tropical plants including those consumed for food and for medicinal purposes, the nature and microvariability of plutonium particles in the soil and unusual pathways of exposure, e.g., that which might be associated with cooking and washing outdoors and inadvertent soil ingestion. A study on the prevalence of thyroid disease is also being conducted and the geographic pattern of disease may be useful as a bioindicator of the geographic pattern of exposure to radioiodine. Finally, an examination is underway of gummed film, fixed-instrument, and aerial survey data accumulated during the 1950's by the Health and Safety Laboratory of the U.S. AEC. This article gives an overview of these many different activities and a summary of recent dose assessments.

  9. SU-F-T-399: Migration of Treatment Planning Systems Without Beam Data Measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tolakanahalli, R; Tewatia, D

    2016-06-15

    Purpose: Data acquisition for commissioning is steered by Treatment Planning System (TPS) requirements which can be cumbersome and time consuming involving significant clinic downtime. The purpose of this abstract is to answer if we could circumvent this by extracting data from existing TPS and speed up the process. Methods: Commissioning beam data was obtained from a clinically commissioned TPS (Pinnacle™) using Matlab™ generated Pinnacle™ executable scripts to commission a secondary 3D dose verification TPS (Eclipse™). Profiles and output factors for commissioning as required by Eclipse™ were computed on a 50 cm{sup 3} water phantom at a dose grid resolution ofmore » 2mm3. Verification doses were computed and compared to clinical TPS dose profiles as per TG-106 guidelines. Standard patient plans from Pinnacle™ including IMRT and VMAT plans were re-computed keeping the same monitor units (in order to perform true comparison) using Eclipse™. Computed dose was exported back to Pinnacle for comparison to original plans. This methodology enables us to alleviate all ambiguities that arise in such studies. Results: Profile analysis using in-house software for 6x, showed that for all field sizes including small MLC generated fields, 100% of infield and penumbra data points of Eclipse™ match Pinnacle™ generated and measured profiles with 2%/2 mm gamma criteria. Excellent agreement was observed in the penumbra regions, with all data points passing DTA criteria for complex C-shaped and S-shaped profiles. Patient plan dose volume histograms (DVHs) and isodose lines agreed well to within a 1.5% for target coverage. Conclusion: Secondary 3D dose checking is of utmost importance with advanced techniques such as IMRT and VMAT. Migration of TPS is possible without compromising accuracy or enduring the cumbersome measurement of commissioning data. Economizing time for commissioning such a verification system or for migration of TPS can add great QA value and minimize downtime.« less

  10. Feasibility study for distributed dose monitoring in ionizing radiation environments with standard and custom-made optical fibers

    NASA Astrophysics Data System (ADS)

    Van Uffelen, Marco; Berghmans, Francis; Brichard, Benoit; Borgermans, Paul; Decréton, Marc C.

    2002-09-01

    Optical fibers stimulate much interest since many years for their potential use in various nuclear environments, both for radiation tolerant and EMI-free data communication as well as for distributed sensing. Besides monitoring temperature and stress, measuring ionizing doses with optical fibers is particularly essential in applications such as long-term nuclear waste disposal monitoring, and for real-time aging monitoring of power and signal cables installed inside a reactor containment building. Two distinct options exist to perform optical fiber dosimetry. First, find an accurate model for a restricted application field that accounts for all the parameters that influence the radiation response of a standard fiber, or second, develop a dedicated fiber with a response that will solely depend on the deposited energy. Using various models presented in literature, we evaluate both standard commercially available and custom-made optical fibers under gamma radiation, particularly for distributed dosimetry applications with an optical time domain reflectometer (OTDR). We therefore present the radiation induced attenuation at near-infrared telecom wavelengths up to MGy total dose levels, with dose rates ranging from about 1 Gy/h up to 1 kGy/h, whereas temperature was raised step-wise from 25 °C to 85 °C. Our results allow to determine and compare the practical limitations of distributed dose measurements with both fiber types in terms of temperature sensitivity, dose estimation accuracy and spatial resolution.

  11. Incorporating deliverable monitor unit constraints into spot intensity optimization in intensity modulated proton therapy treatment planning

    PubMed Central

    Cao, Wenhua; Lim, Gino; Li, Xiaoqiang; Li, Yupeng; Zhu, X. Ronald; Zhang, Xiaodong

    2014-01-01

    The purpose of this study is to investigate the feasibility and impact of incorporating deliverable monitor unit (MU) constraints into spot intensity optimization in intensity modulated proton therapy (IMPT) treatment planning. The current treatment planning system (TPS) for IMPT disregards deliverable MU constraints in the spot intensity optimization (SIO) routine. It performs a post-processing procedure on an optimized plan to enforce deliverable MU values that are required by the spot scanning proton delivery system. This procedure can create a significant dose distribution deviation between the optimized and post-processed deliverable plans, especially when small spot spacings are used. In this study, we introduce a two-stage linear programming (LP) approach to optimize spot intensities and constrain deliverable MU values simultaneously, i.e., a deliverable spot intensity optimization (DSIO) model. Thus, the post-processing procedure is eliminated and the associated optimized plan deterioration can be avoided. Four prostate cancer cases at our institution were selected for study and two parallel opposed beam angles were planned for all cases. A quadratic programming (QP) based model without MU constraints, i.e., a conventional spot intensity optimization (CSIO) model, was also implemented to emulate the commercial TPS. Plans optimized by both the DSIO and CSIO models were evaluated for five different settings of spot spacing from 3 mm to 7 mm. For all spot spacings, the DSIO-optimized plans yielded better uniformity for the target dose coverage and critical structure sparing than did the CSIO-optimized plans. With reduced spot spacings, more significant improvements in target dose uniformity and critical structure sparing were observed in the DSIO- than in the CSIO-optimized plans. Additionally, better sparing of the rectum and bladder was achieved when reduced spacings were used for the DSIO-optimized plans. The proposed DSIO approach ensures the deliverability of optimized IMPT plans that take into account MU constraints. This eliminates the post-processing procedure required by the TPS as well as the resultant deteriorating effect on ultimate dose distributions. This approach therefore allows IMPT plans to adopt all possible spot spacings optimally. Moreover, dosimetric benefits can be achieved using smaller spot spacings. PMID:23835656

  12. SU-E-T-585: Optically-Stimulated Luminescent Dosimeters for Monitoring Pacemaker Dose in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apicello, L; Riegel, A; Jamshidi, A

    2015-06-15

    Purpose: A sufficient amount of ionizing radiation can cause failure to components of pacemakers. Studies have shown that permanent damage can occur after a dose of 10 Gy and minor damage to functionality occurs at doses as low as 2 Gy. Optically stimulated thermoluminescent dosimeters (OSLDs) can be used as in vivo dosimeters to predict dose to be deposited throughout the treatment. The purpose of this work is to determine the effectiveness of using OSLDs for in vivo dosimetry of pacemaker dose. Methods: As part of a clinical in vivo dosimetry experience, OSLDs were placed at the site of themore » pacemaker by the therapist for one fraction of the radiation treatment. OSLD measurements were extrapolated to the total dose to be received by the pacemaker during treatment. A total of 79 measurements were collected from November 2011 to December 2013 on six linacs. Sixty-six (66) patients treated in various anatomical sites had the dose of their pacemakers monitored. Results: Of the 79 measurements recorded, 76 measurements (96 %) were below 2 Gy. The mean and standard deviation were 50.12 ± 76.41 cGy. Of the 3 measurements that exceeded 2 Gy, 2 measurements matched the dose predicted in the treatment plan and 1 was repeated after an unexpectedly high Result. The repeated measurement yielded a total dose less than 2 Gy. Conclusion: This analysis suggests OSLDs may be used for in vivo monitoring of pacemaker dose. Further research should be performed to assess the effect of increased backscatter from the pacemaker device.« less

  13. Radiologic Monitoring of Faculty and Staff in an Electrophysiology Lab Using a Real-Time Dose Monitoring System

    ERIC Educational Resources Information Center

    Chardenet, Kathleen A.

    2016-01-01

    Purpose: A real-time dose management system was used to determine if radiation exposure levels would decrease when providers were privy to their real-time radiation exposure levels. Six aggregate categories of providers were first blinded (phase 1) and subsequently made aware of their radiation exposure levels during electrophysiology procedures…

  14. NRC Monitoring of Salt Waste Disposal at the Savannah River Site - 13147

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinkston, Karen E.; Ridge, A. Christianne; Alexander, George W.

    2013-07-01

    As part of monitoring required under Section 3116 of the Ronald W. Reagan National Defense Authorization Act for Fiscal Year 2005 (NDAA), the NRC staff reviewed an updated DOE performance assessment (PA) for salt waste disposal at the Saltstone Disposal Facility (SDF). The NRC staff concluded that it has reasonable assurance that waste disposal at the SDF meets the 10 CFR 61 performance objectives for protection of individuals against intrusion (chap.61.42), protection of individuals during operations (chap.61.43), and site stability (chap.61.44). However, based on its evaluation of DOE's results and independent sensitivity analyses conducted with DOE's models, the NRC staffmore » concluded that it did not have reasonable assurance that DOE's disposal activities at the SDF meet the performance objective for protection of the general population from releases of radioactivity (chap.61.41) evaluated at a dose limit of 0.25 mSv/yr (25 mrem/yr) total effective dose equivalent (TEDE). NRC staff also concluded that the potential dose to a member of the public is expected to be limited (i.e., is expected to be similar to or less than the public dose limit in chap.20.1301 of 1 mSv/yr [100 mrem/yr] TEDE) and is expected to occur many years after site closure. The NRC staff used risk insights gained from review of the SDF PA, its experience monitoring DOE disposal actions at the SDF over the last 5 years, as well as independent analysis and modeling to identify factors that are important to assessing whether DOE's disposal actions meet the performance objectives. Many of these factors are similar to factors identified in the NRC staff's 2005 review of salt waste disposal at the SDF. Key areas of interest continue to be waste form and disposal unit degradation, the effectiveness of infiltration and erosion controls, and estimation of the radiological inventory. Based on these factors, NRC is revising its plan for monitoring salt waste disposal at the SDF in coordination with South Carolina Department of Health and Environmental Control (SCDHEC). DOE has completed or begun additional work related to salt waste disposal to address these factors. NRC staff continues to evaluate information related to the performance of the SDF and has been working with DOE and SCDHEC to resolve NRC staff's technical concerns. (authors)« less

  15. Application of a Web-Enabled Leg Training System for the Objective Monitoring and Quantitative Analysis of Exercise-Induced Fatigue

    PubMed Central

    Dedova, Irina V

    2016-01-01

    Background Sustained cardiac rehabilitation is the key intervention in the prevention and treatment of many human diseases. However, implementation of exercise programs can be challenging because of early fatigability in patients with chronic diseases, overweight individuals, and aged people. Current methods of fatigability assessment are based on subjective self-reporting such as rating of perceived exertion or require specialized laboratory conditions and sophisticated equipment. A practical approach allowing objective measurement of exercise-induced fatigue would be useful for the optimization of sustained delivery of cardiac rehabilitation to improve patient outcomes. Objectives The objective of this study is to develop and validate an innovative approach, allowing for the objective assessment of exercise-induced fatigue using the Web-enabled leg rehabilitation system. Methods MedExercise training devices were equipped with wireless temperature sensors in order to monitor their usage by temperature rise in the resistance unit (Δt°). Since Δt° correlated with the intensity and duration of exercise, this parameter was used to characterize participants’ leg work output (LWO). Personal smart devices such as laptop computers with wireless gateways and relevant software were used for monitoring of self-control training. Connection of smart devices to the Internet and cloud-based software allowed remote monitoring of LWO in participants training at home. Heart rates (HRs) were measured by fingertip pulse oximeters simultaneously with Δt° in 7 healthy volunteers. Results Exercise-induced fatigue manifested as the decline of LWO and/or rising HR, which could be observed in real-time. Conversely, training at the steady-state LWO and HR for the entire duration of exercise bout was considered as fatigue-free. The amounts of recommended daily physical activity were expressed as the individual Δt° values reached during 30-minute fatigue-free exercise of moderate intensity resulting in a mean of 8.1°C (SD 1.5°C, N=7). These Δt° values were applied as the thresholds for sending automatic notifications upon taking the personalized LWO doses by self-control training at home. While the mean time of taking LWO doses was 30.3 (SD 4.1) minutes (n=25), analysis of times required to reach the same Δt° by the same participant revealed that longer durations were due to fatigability, manifesting as reduced LWO at the later stages of training bouts. Typically, exercising in the afternoons associated with no fatigue, although longer durations of evening sessions suggested a diurnal fatigability pattern. Conclusions This pilot study demonstrated the feasibility of objective monitoring of fatigue development in real-time and online as well as retrospective fatigability quantification by the duration of training bouts to reach the same exercise dose. This simple method of leg training at home accompanied by routine fatigue monitoring might be useful for the optimization of exercise interventions in primary care and special populations. PMID:27549345

  16. High phenobarbital clearance during continuous renal replacement therapy: a case report and pharmacokinetic analysis.

    PubMed

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-08-01

    Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring.A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure.Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus.The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed.Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring.

  17. High Phenobarbital Clearance During Continuous Renal Replacement Therapy

    PubMed Central

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-01-01

    Abstract Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring. A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure. Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus. The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed. Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring. PMID:25101986

  18. Reversal of neuromuscular block with sugammadex: a comparison of the corrugator supercilii and adductor pollicis muscles in a randomized dose-response study.

    PubMed

    Yamamoto, S; Yamamoto, Y; Kitajima, O; Maeda, T; Suzuki, T

    2015-08-01

    Neuromuscular monitoring using the corrugator supercilii muscle is associated with a number of challenges. The aim of this study was to assess reversal of a rocuronium-induced neuromuscular blockade with sugammadex according to monitoring either using the corrugator supercilii muscle or the adductor pollicis muscle. We hypothesized that a larger dose of sugammadex would be required to obtain a train-of-four (TOF) ratio of 1.0 with the corrugator supercilii muscle than with the adductor pollicis muscle. Forty patients aged 20-60 years and 40 patients aged ≥ 70 years were enrolled. After induction of anesthesia, we recorded the corrugator supercilii muscle response to facial nerve stimulation and the adductor pollicis muscle response to ulnar nerve stimulation using acceleromyography. All patients received 1 mg/kg rocuronium. When the first twitch (T1) of TOF recovered to 10% of control values at the corrugator supercilii, rocuronium infusion was commenced to maintain a T1 of 10% of the control at the corrugator supercilii. Immediately after discontinuation of rocuronium infusion, 2 mg/kg or 4 mg/kg of sugammadex was administered. The time for recovery to a TOF ratio of 1.0 and the number of patients not reaching a TOF ratio of 1.0 by 5 min at each dose and muscle was recorded. When neuromuscular block at the corrugator supercilii was maintained at a T1 of 10% of control, that at the adductor pollicis was deep (post-tetanic count ≤ 5). Sugammadex 4 mg/kg completely antagonized neuromuscular block at both muscles within 5 min. The time to a TOF ratio of 1.0 at the adductor pollicis was significantly longer in the group ≥ 70 years than the group 20-60 years (mean (SD): 178 (42.8) s vs. 120 (9.4) s, P < 0.0001). In contrast, 2 mg/kg sugammadex reversed neuromuscular blockade at the corrugator supercilii but not at the adductor pollicis, with 10 patients in the group 20-60 years and 8 patients in the group ≥ 70 years requiring an additional sugammadex (P < 0.05 vs. 4 mg/kg sugammadex). Sugammadex 4 mg/kg was required to reverse a moderate rocuronium-induced neuromuscular block when the corrugator supercilii muscle is used for monitoring. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Sugammadex: Appropriate Use in the Context of Budgetary Constraints.

    PubMed

    Cammu, Guy

    2018-01-01

    The purpose of this review is to assess how sugammadex impacts postoperative residual curarization using appropriate doses based on neuromuscular transmission monitoring and whether the advantages of sugammadex versus neostigmine outweigh its higher cost. An accurate assessment of neuromuscular blockade with monitoring is necessary before selecting neostigmine versus sugammadex for reversal at the end of surgery to overcome incomplete neuromuscular recovery. The main advantages of sugammadex over neostigmine are its predictability and its ability to extend the range of blockade reversal. The cost of sugammadex is greater when higher doses of sugammadex are required for antagonism of deep block. Sugammadex probably has the potential to be cost-effective compared with neostigmine if its time savings are put to productive use in clinical practice. However, to date, the economic benefits of the drug are unknown. With sugammadex, almost any degree of neuromuscular block can be antagonized within 2-3 min; neostigmine is the only reversal agent effective against benzylisoquinolines and can ideally be used for reversal of lower levels of residual paralysis. The performance of the more expensive sugammadex on improving patient outcomes may depend on several elements of clinical strategy.

  20. [Personal dose monitoring of radiation workers in medical institutions at the municipal level and below in a city from 2011 to 2014].

    PubMed

    Wang, C; Mo, S F; Zhang, J B; Li, J R; Huang, R L; Tan, H Y

    2017-08-20

    Objective: To determine the personal dose level of radiation workers in medical institutions at the municipal level and below in a city, and to provide a scientific support for strengthening the radiation protection in the city's medical institutions. Methods: Information of the successful applicants for the "Radiation Worker Permit" from 174 medical institutions at the municipal level and below was collected from October 1, 2011 to December 31, 2014. The annual effective dose was calculated based on the personal dose monitoring report, and indicators including sex, permit application time, hospital level, type of occupational radiation, length of radiation work, blood test, and micronucleated lymphocyte rate were analyzed. Results: Of the 1 143 radiation worker permit applications submitted by medical institutions the municipal level and below in this city from 2011 to 2014, 1 123 provided at least one personal dose monitoring report. The annual effective dose of the radiation workers was 0-4.76 mSv (mean 0.31±0.40 mSv) , and the collective annual effective dose was 351.96 mSv. The annual effective dose was significantly different between radiation workers with different times of permit application, hospital levels, and types of occupational radiation ( P <0.05) . Interventional radiology workers had the highest annual effective dose (0.63 mSv) , and annual effective dose was significantly different between interventional radiology workers with different lengths of radiation work ( H =10.812, P <0.05) . Conclusion: The personal radiation dose of radiation workers in medical institutions at the municipal level and below in this city is maintained at a relatively low level, suggesting that the occupational environment is relatively safe for these workers. However, more focus should be placed on clinical interventional radiology workers.

  1. The systemic toxicity of equipotent proxymetacaine, oxybuprocaine, and bupivacaine during continuous intravenous infusion in rats.

    PubMed

    Hung, Ching-Hsia; Liu, Kuo-Sheng; Shao, Dong-Zi; Cheng, Kuang-I; Chen, Yu-Chung; Chen, Yu-Wen

    2010-01-01

    Although proxymetacaine and oxybuprocaine produce topical ocular and spinal anesthesia, they have never been tested as cutaneous anesthetics. We compared cutaneous analgesia of proxymetacaine and oxybuprocaine with bupivacaine and tested their central nervous system and cardiovascular toxicity. After blockade of cutaneous trunci muscle reflex with subcutaneous injections, we evaluated the local anesthetic effect of proxymetacaine and oxybuprocaine on cutaneous analgesia in rats. After i.v. infusions of equipotent doses of oxybuprocaine, proxymetacaine, and bupivacaine, we observed the onset time of seizure, apnea, and impending death and monitored mean arterial blood pressure and heart rate. Proxymetacaine and oxybuprocaine acted like bupivacaine and produced dose-related cutaneous analgesia. On a 50% effective dose basis, the ranks of potencies were proxymetacaine > oxybuprocaine > bupivacaine (P < 0.01). Under equipotent doses, the infusion times of proxymetacaine or oxybuprocaine required to cause seizure, apnea, and impending death were longer than that of bupivacaine (P < 0.05). The decrease in mean arterial blood pressure and heart rate was slower with oxybuprocaine and proxymetacaine compared with bupivacaine (P < 0.05 for the differences) at equipotent doses. Oxybuprocaine and proxymetacaine were more potent at producing cutaneous anesthesia but were less potent than bupivacaine at producing central nervous system and cardiovascular toxicity.

  2. Are bioequivalence studies of levothyroxine sodium formulations in euthyroid volunteers reliable?

    PubMed

    Blakesley, Vicky; Awni, Walid; Locke, Charles; Ludden, Thomas; Granneman, G Richard; Braverman, Lewis E

    2004-03-01

    Levothyroxine (LT4) has a narrow therapeutic index. Consequently, precise standards for assessing the bioequivalence of different LT4 products are vital. We examined the methodology that the Food and Drug Administration (FDA) recommends for comparing the bioavailability of LT4 products, as well as three modifications to correct for endogenous, thyroxine (T4) levels, to determine if the methodology could distinguish LT4 products that differ by 12.5%, 25%, or 33%. With no baseline correction for the endogenous T4 pool, differences in administered LT4 doses that differed by 25%-33% could not be detected (450 microg and 400 microg doses versus 600 microg dose, respectively). The three mathematical correction methods could distinguish the doses that differed by 25% and 33%. None of the correction methods could distinguish dosage strengths that differed by 12.5% (450 microg versus 400 microg). Dose differences within this range are known to result in clinically relevant differences in safety and effectiveness. Methods of analysis of bioequivalence data that do not consider endogenous T4 concentrations confound accurate quantitation and interpretation of LT4 bioavailability. As a result, products inappropriately deemed bioequivalent may put patients at risk for iatrogenic hyperthyroidism or hypothyroidism. More precise methods for defining bioequivalence are required in order to ensure that LT4 products accepted as bioequivalent will perform equivalently in patients without the need for further monitoring and retitration of their dose.

  3. NP001 regulation of macrophage activation markers in ALS: A phase I clinical and biomarker study

    PubMed Central

    MILLER, ROBERT G.; ZHANG, RONGZHEN; BLOCK, GILBERT; KATZ, JONATHAN; BAROHN, RICHARD; KASARSKIS, EDWARD; FORSHEW, DALLAS; GOPALAKRISHNAN, VIDHYA; MCGRATH, MICHAEL S.

    2017-01-01

    This is a phase I, placebo-controlled, single ascending dose safety and tolerability study of NP001 in patients with ALS. NP001 is a novel regulator of inflammatory macrophages and monocytes. As ALS progression is thought to be related to neuroinflammation, an additional objective of the study was to assess the effects of NP001 administration on monocyte activation markers. Thirty-two ALS patients were enrolled and received either placebo (eight) or one of four (six at each dose) ascending single i.v. doses (0.2, 0.8, 1.6 and 3.2 mg/kg NP001). Patients were monitored for safety, and blood monocyte immune activation markers CD16 and HLA-DR were assessed pre- and 24 h post-dosing. Changes from baseline were calculated. Results showed that NP001 was generally safe and well tolerated. Importantly, a single dose of NP001 caused a dose-dependent reduction in expression of monocyte CD16, a marker of monocyte activation/inflammation. Additionally, monocyte HLA-DR expression was also decreased in those patients with elevated values at baseline. In conclusion, these data indicate that NP001 has an acute effect on inflammatory monocytes in ALS patient blood. The potential for modulation of inflammation in the context of ALS disease progression will require further study with long-term follow-up. PMID:25192333

  4. PaxVax CVD 103-HgR single-dose live oral cholera vaccine.

    PubMed

    Levine, Myron M; Chen, Wilbur H; Kaper, James B; Lock, Michael; Danzig, Lisa; Gurwith, Marc

    2017-03-01

    Cholera remains a problem in developing countries and a risk for travelers. Hypochlorhydria, blood group O, cardiac and renal disease increase the risk of developing cholera gravis. Oral vaccines containing inactivated Vibrio cholerae and requiring two doses are available in some countries. No cholera vaccine had been available for U.S. travelers for decades until 2016 when CVD 103-HgR (VAXCHORA™), an oral live attenuated vaccine, was licensed by the U.S. FDA. Areas covered: Enduring protection following wild-type cholera provided the rationale to develop a single-dose live oral vaccine. CVD 103-HgR is well-tolerated and protects against cholera caused by V. cholerae O1 of either serotype (Inaba, Ogawa) and biotype (El Tor, Classical). Since 90% vaccine efficacy is evident 10 days post-ingestion of a single dose, CVD 103-HgR can rapidly protect travelers. Vibriocidal antibody seroconversion correlates with protection; >90% of U.S. adult (including elderly) vaccinees seroconvert. The U.S. Public Health Service's Advisory Committee on Immunization Practices recommends CVD 103-HgR for U.S. travelers to areas of ongoing cholera transmission. Expert commentary: Next steps include evaluations in children, post-licensure safety and effectiveness monitoring, diminishing cold chain constraints, optimizing a 'high-dose' formulation for developing countries, and diminishing/eliminating the need for water to administer a dose.

  5. Management of rivaroxaban in relation to bodyweight and body mass index

    PubMed Central

    Uprichard, James

    2016-01-01

    Being overweight or obese is associated with a higher individual risk of venous thromboembolism and poorer postprocedural outcomes after hip or knee replacement surgery. In addition, there is evidence that obesity represents a significant driving factor for the current and projected prevalence of atrial fibrillation. Rivaroxaban and other direct oral anticoagulants offer fixed-dose regimens for these indications. They do not require therapeutic drug monitoring or dose adjustment according to the weight of the patient. However, primary care physicians seem to be hesitant to accept the concept of a fixed-dose regimen for patients at extremes of weight, perhaps because of familiarity with weight-based dosing of other drugs including low molecular weight heparins. The main concerns related to unadjusted dosing are increased exposure in underweight patients leading to a risk of excessive bleeding and conversely to underanticoagulation of overweight patients. Rivaroxaban has shown similar efficacy and a similar or better safety profile compared with standard treatment for several venous and arterial indications, including venous thromboembolism, nonvalvular atrial fibrillation, and acute coronary syndrome. Prespecified subgroup analyses of patients stratified by weight or body mass index demonstrated outcomes that were consistent with the overall analysis and within each weight and body mass index group. The results suggest that standard-dose rivaroxaban can be safely prescribed in adult patients of all weights. PMID:27090286

  6. Monitoring the eye lens: which dose quantity is adequate?

    NASA Astrophysics Data System (ADS)

    Behrens, R.; Dietze, G.

    2010-07-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity Hp(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity Hp(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of Hp(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of Hp(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of Hp(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

  7. Monitoring the eye lens: which dose quantity is adequate?

    PubMed

    Behrens, R; Dietze, G

    2010-07-21

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. The question of which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens arises from this situation. While in many countries dosemeters calibrated in terms of the dose equivalent quantity H(p)(0.07) have been seen as being adequate for monitoring the dose to the eye lens, this might be questionable in the case of reduced dose limits and, thus, it may become necessary to use the dose equivalent quantity H(p)(3) for this purpose. To discuss this question, the dose conversion coefficients for the equivalent dose of the eye lens (in the following eye lens dose) were determined for realistic photon and beta radiation fields and compared with the values of the corresponding conversion coefficients for the different operational quantities. The values obtained lead to the following conclusions: in radiation fields where most of the dose comes from photons, especially x-rays, it is appropriate to use dosemeters calibrated in terms of H(p)(0.07) on a slab phantom, while in other radiation fields (dominated by beta radiation or unknown contributions of photon and beta radiation) dosemeters calibrated in terms of H(p)(3) on a slab phantom should be used. As an alternative, dosemeters calibrated in terms of H(p)(0.07) on a slab phantom could also be used; however, in radiation fields containing beta radiation with the end point energy near 1 MeV, an overestimation of the eye lens dose by up to a factor of 550 is possible.

  8. Impact of pelvic nodal irradiation with intensity-modulated radiotherapy on treatment of prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Robert A.; Hannoun-Levi, Jean-Michel; Horwitz, Eric

    2006-10-01

    Purpose: The aim of this study was to evaluate the feasibility of treating the pelvic lymphatic regions during prostate intensity-modulated radiotherapy (IMRT) with respect to our routine acceptance criteria. Methods and Materials: A series of 10 previously treated prostate patients were randomly selected and the pelvic lymphatic regions delineated on the fused magnetic resonance/computed tomography data sets. A targeting progression was formed from the prostate and proximal seminal vesicles only to the inclusion of all pelvic lymphatic regions and presacral region resulting in 5 planning scenarios of increasing geometric difficulty. IMRT plans were generated for each stage for two acceleratormore » manufacturers. Dose volume histogram data were analyzed with respect to dose to the planning target volumes, rectum, bladder, bowel, and normal tissue. Analysis was performed for the number of segments required, monitor units, 'hot spots,' and treatment time. Results: Both rectal endpoints were met for all targets. Bladder endpoints were not met and the bowel endpoint was met in 40% of cases with the inclusion of the extended and presacral lymphatics. A significant difference was found in the number of segments and monitor units with targeting progression and between accelerators, with the smaller beamlets yielding poorer results. Treatment times between the 2 linacs did not exhibit a clinically significant difference when compared. Conclusions: Many issues should be considered with pelvic lymphatic irradiation during IMRT delivery for prostate cancer including dose per fraction, normal structure dose/volume limits, planning target volumes generation, localization, treatment time, and increased radiation leakage. We would suggest that, at a minimum, the endpoints used in this work be evaluated before beginning IMRT pelvic nodal irradiation.« less

  9. Update on the cardiovascular profile of fingolimod in the therapy of relapsing-remitting multiple sclerosis (MS).

    PubMed

    Meissner, Axel; Limmroth, Volker

    2016-07-01

    Fingolimod (FTY720) has been approved as the first oral representative of the class of sphingosine-1-phosphate (S1P) receptor modulators for the treatment of relapsing-remitting multiple sclerosis (MS). Besides inducing vaso-relaxation, fingolimod can also influence electrical conduction in the myocardium and vascular endothelium by having a transient negative chronotropic effect on the sinus node. Cardiac safety and tolerability of fingolimod in the cardiac sense were reviewed by analysing the data collected from the FREEDOMS and TRANSFORMS studies -both relevant studies for marketing authorisation, from their extension studies, as well as the clinical data collected from a practice-related MS patient cohort with cardiovascular risk factors and corresponding co-medication (FIRST study). The safety analyses on file gave no indication of any increased cardiovascular risk. The 2-3mmHg increase in blood pressure observed after the first dose of fingolimod has no therapeutic consequences. The first dose of 0.5mg fingolimod resulted in an average decrease in heart rate of 7-8beats/min. The onset of effect occurred approximately 1-2h after the first dose and the nadir was reached after approximately 4-5h. This negative chronotropic effect returned to normal after internalisation of the S1P1 receptors on maintenance therapy. There were no indications that patients with cardiac risk factors required closer observation beyond the monitoring recommended by the EMA following the first dose of fingolimod. Case study observations from the routine clinical setting show that patients accept this method of monitoring, which they assess as being a positive aspect of attentive medical care and concern. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Real time laser speckle imaging monitoring vascular targeted photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Goldschmidt, Ruth; Vyacheslav, Kalchenko; Scherz, Avigdor

    2017-02-01

    Laser speckle imaging is a technique that has been developed to non-invasively monitor in vivo blood flow dynamics and vascular structure, at high spatial and temporal resolution. It can record the full-field spatio-temporal characteristics of microcirculation and has therefore, often been used to study the blood flow in tumors after photodynamic therapy (PDT). Yet, there is a paucity of reports on real-time laser speckle imaging (RTLSI) during PDT. Vascular-targeted photodynamic therapy (VTP) with WST11, a water-soluble bacteriochlorophyll derivative, achieves tumor ablation through rapid occlusion of the tumor vasculature followed by a cascade of events that actively kill the tumor cells. WST11-VTP has been already approved for treatment of early/intermediate prostate cancer at a certain drug dose, time and intensity of illumination. Application to other cancers may require different light dosage. However, incomplete vascular occlusion at lower light dose may result in cancer cell survival and tumor relapse while excessive light dose may lead to toxicity of nearby healthy tissues. Here we provide evidence for the feasibility of concomitant RTLSI of the blood flow dynamics in the tumor and surrounding normal tissues during and after WST11-VTP. Fast decrease in the blood flow is followed by partial mild reperfusion and a complete flow arrest within the tumor by the end of illumination. While the primary occlusion of the tumor feeding arteries and draining veins agrees with previous data published by our group, the late effects underscore the significance of light dose control to minimize normal tissue impairment. In conclusion- RTSLI application should allow to optimize VTP efficacy vs toxicity in both the preclinical and clinical arenas.

  11. Cost effectiveness of novel oral anticoagulants for stroke prevention in atrial fibrillation depending on the quality of warfarin anticoagulation control.

    PubMed

    Janzic, Andrej; Kos, Mitja

    2015-04-01

    Vitamin K antagonists, such as warfarin, are standard treatments for stroke prophylaxis in patients with atrial fibrillation. Patient outcomes depend on quality of warfarin management, which includes regular monitoring and dose adjustments. Recently, novel oral anticoagulants (NOACs) that do not require regular monitoring offer an alternative to warfarin. The aim of this study was to evaluate whether cost effectiveness of NOACs for stroke prevention in atrial fibrillation depends on the quality of warfarin control. We developed a Markov decision model to simulate warfarin treatment outcomes in relation to the quality of anticoagulation control, expressed as percentage of time in the therapeutic range (TTR). Standard treatment with adjusted-dose warfarin and improved anticoagulation control by genotype-guided dosing were compared with dabigatran, rivaroxaban, apixaban and edoxaban. The analysis was performed from the Slovenian healthcare payer perspective using 2014 costs. In the base case, the incremental cost-effectiveness ratio for apixaban, dabigatran and edoxaban was below the threshold of €25,000 per quality-adjusted life-years compared with adjusted-dose warfarin with a TTR of 60%. The probability that warfarin was a cost-effective option was around 1%. This percentage rises as the quality of anticoagulation control improves. At a TTR of 70%, warfarin was the preferred treatment in half the iterations. The cost effectiveness of NOACs for stroke prevention in patients with nonvalvular atrial fibrillation who are at increased risk for stroke is highly sensitive to warfarin anticoagulation control. NOACs are more likely to be cost-effective options in settings with poor warfarin management than in settings with better anticoagulation control, where they may not represent good value for money.

  12. Imaging and characterization of primary and secondary radiation in ion beam therapy

    NASA Astrophysics Data System (ADS)

    Granja, Carlos; Martisikova, Maria; Jakubek, Jan; Opalka, Lukas; Gwosch, Klaus

    2016-07-01

    Imaging in ion beam therapy is an essential and increasingly significant tool for treatment planning and radiation and dose deposition verification. Efforts aim at providing precise radiation field characterization and online monitoring of radiation dose distribution. A review is given of the research and methodology of quantum-imaging, composition, spectral and directional characterization of the mixed-radiation fields in proton and light ion beam therapy developed by the IEAP CTU Prague and HIT Heidelberg group. Results include non-invasive imaging of dose deposition and primary beam online monitoring.

  13. A beam monitor based on MPGD detectors for hadron therapy

    NASA Astrophysics Data System (ADS)

    Altieri, P. R.; Di Benedetto, D.; Galetta, G.; Intonti, R. A.; Mercadante, A.; Nuzzo, S.; Verwilligen, P.

    2018-02-01

    Remarkable scientific and technological progress during the last years has led to the construction of accelerator based facilities dedicated to hadron therapy. This kind of technology requires precise and continuous control of position, intensity and shape of the ions or protons used to irradiate cancers. Patient safety, accelerator operation and dose delivery should be optimized by a real time monitoring of beam intensity and profile during the treatment, by using non-destructive, high spatial resolution detectors. In the framework of AMIDERHA (AMIDERHA - Enhanced Radiotherapy with HAdron) project funded by the Ministero dell'Istruzione, dell'Università e della Ricerca (Italian Ministry of Education and Research) the authors are studying and developing an innovative beam monitor based on Micro Pattern Gaseous Detectors (MPDGs) characterized by a high spatial resolution and rate capability. The Monte Carlo simulation of the beam monitor prototype was carried out to optimize the geometrical set up and to predict the behavior of the detector. A first prototype has been constructed and successfully tested using 55Fe, 90Sr and also an X-ray tube. Preliminary results on both simulations and tests will be presented.

  14. Changing tides: Adaptive monitoring, assessment, and management of pharmaceutical hazards in the environment through time.

    PubMed

    Gaw, Sally; Brooks, Bryan W

    2016-04-01

    Pharmaceuticals are ubiquitous contaminants in aquatic ecosystems. Adaptive monitoring, assessment, and management programs will be required to reduce the environmental hazards of pharmaceuticals of concern. Potentially underappreciated factors that drive the environmental dose of pharmaceuticals include regulatory approvals, marketing campaigns, pharmaceutical subsidies and reimbursement schemes, and societal acceptance. Sales data for 5 common antidepressants (duloxetine [Cymbalta], escitalopram [Lexapro], venlafaxine [Effexor], bupropion [Wellbutrin], and sertraline [Zoloft]) in the United States from 2004 to 2008 were modeled to explore how environmental hazards in aquatic ecosystems changed after patents were obtained or expired. Therapeutic hazard ratios for Effexor and Lexapro did not exceed 1; however, the therapeutic hazard ratio for Zoloft declined whereas the therapeutic hazard ratio for Cymbalta increased as a function of patent protection and sale patterns. These changes in therapeutic hazard ratios highlight the importance of considering current and future drivers of pharmaceutical use when prioritizing pharmaceuticals for water quality monitoring programs. When urban systems receiving discharges of environmental contaminants are examined, water quality efforts should identify, prioritize, and select target analytes presently in commerce for effluent monitoring and surveillance. © 2015 SETAC.

  15. Management strategies in pancreatic cancer.

    PubMed

    Campen, Christopher J; Dragovich, Tomislav; Baker, Amanda F

    2011-04-01

    Current first-line and adjuvant chemotherapeutic strategies for management of patients with pancreatic cancer are reviewed. Pancreatic adenocarcinoma is the 10th most prevalent cancer and the fourth most common cause of cancer deaths in the United States. More than 80% of patients with pancreatic cancer are diagnosed with locally advanced or metastatic disease and are not candidates for surgery; these patients often require multimodal treatment. The most widely used chemotherapy for such patients, as well as patients requiring adjuvant therapy after surgery, is gemcitabine or gemcitabine-based chemotherapy. All current chemotherapies for pancreatic cancer are associated with dose-limiting hematologic toxicity and other adverse effects that require ongoing monitoring and dosage adjustment to balance the benefits and risks of treatment. Pharmacists can play an important role in monitoring and providing drug information and guidance to patients and oncologists. Current investigational strategies include efforts to improve chemotherapy response rates and outcomes through modulation of cell signaling pathways and use of nanotechnology to improve drug delivery. Current management of pancreatic cancer is multifaceted, involving anticancer therapy, supportive care, and toxicity management. Standard systemic therapy with gemcitabine as a single agent or in combination with other cytotoxic agents provides modest benefits in terms of response and symptom control.

  16. In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.

    PubMed

    Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J

    2004-01-01

    In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.

  17. Listening to music with personal listening devices: monitoring the noise dose using a smartphone application.

    PubMed

    Kaplan-Neeman, Ricky; Muchnik, Chava; Amir, Noam

    2017-06-01

    To monitor listening habits to personal listening devices (PLDs) using a smartphone application and to compare actual listening habits to self-report data. Two stages: self-report listening habits questionnaire, and real-time monitoring of listening habits through a smartphone application. Overall 117 participants aged 18-34 years (mean 25.5 years) completed the questionnaire, and of them, 40 participants (mean age: 25.2 years) were monitored for listening habits during two weeks. Questionnaire main findings indicated that most of the participants reported listening for 4-7 days a week, for at least 30 min at high listening levels with volume control settings at 75-100%. Monitored data showed that actual listening days per week were 1.5-6.5 d, with mean continuous time of 1.56 h, and mean volume control setting of 7.39 (on a scale of 1-15). Eight participants (22%) were found to exceed the 100% noise dose at least once during the monitoring period. One participant (2.7%) exceeded the weekly 100% daily noise dose. Correlations between actual measurements and self-report data were low to moderate. Results confirmed the feasibility of monitoring listening habits by a smartphone application, and underscore the need for such a tool to enable safe listening behaviour.

  18. The pharmacology and management of the vitamin K antagonists: the Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy.

    PubMed

    Ansell, Jack; Hirsh, Jack; Poller, Leon; Bussey, Henry; Jacobson, Alan; Hylek, Elaine

    2004-09-01

    This article concerning the pharmacokinetics and pharmacodynamics of vitamin K antagonists (VKAs) is part of the Seventh American College of Chest Physicians Conference on Antithrombotic and Thrombolytic Therapy: Evidence-Based Guidelines. The article describes the antithrombotic effect of VKAs, the monitoring of anticoagulation intensity, the clinical applications of VKA therapy, and the optimal therapeutic range of VKAs, and provides specific management recommendations. Grade 1 recommendations are strong, and indicate that the benefits do, or do not, outweigh the risks, burdens, and costs. Grade 2 suggests that individual patient's values may lead to different choices (for a full understanding of the grading see Guyatt et al, CHEST 2004; 126:179S-187S). Among the key recommendations in this article are the following: for dosing of VKAs, we suggest the initiation of oral anticoagulation therapy with doses between 5 and 10 mg for the first 1 or 2 days for most individuals, with subsequent dosing based on the international normalized ratio (INR) response (Grade 2B). In the elderly and in other patient subgroups with an elevated bleeding risk, we suggest a starting dose at < or = 5 mg (Grade 2C). We recommend basing subsequent doses after the initial two or three doses on the results of INR monitoring (Grade 1C). The article also includes several specific recommendations for the management of patients with INRs above the therapeutic range and for patients requiring invasive procedures. For example, in patients with mild to moderately elevated INRs without major bleeding, we suggest that when vitamin K is to be given it be administered orally rather than subcutaneously (Grade 1A). For the management of patients with a low risk of thromboembolism, we suggest stopping warfarin therapy approximately 4 days before they undergo surgery (Grade 2C). For patients with a high risk of thromboembolism, we suggest stopping warfarin therapy approximately 4 days before surgery, to allow the INR to return to normal, and beginning therapy with full-dose unfractionated heparin or full-dose low-molecular-weight heparin as the INR falls (Grade 2C). In patients undergoing dental procedures, we suggest the use of tranexamic acid mouthwash (Grade 2B) or epsilon amino caproic acid mouthwash without interrupting anticoagulant therapy (Grade 2B) if there is a concern for local bleeding. For most patients who have a lupus inhibitor, we suggest a therapeutic target INR of 2.5 (range, 2.0 to 3.0) [Grade 2B]. In patients with recurrent thromboembolic events with a therapeutic INR or other additional risk factors, we suggest a target INR of 3.0 (range, 2.5 to 3.5) [Grade 2C]. As models of anticoagulation monitoring and management, we recommend that clinicians incorporate patient education, systematic INR testing, tracking, and follow-up, and good communication with patients concerning results and dosing decisions (Grade 1C+).

  19. Predicted Blood Glucose from Insulin Administration Based on Values from Miscoded Glucose Meters

    PubMed Central

    Raine, Charles H.; Pardo, Scott; Parkes, Joan Lee

    2008-01-01

    Objectives The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205–210, 2007). It attempts to relate potential insulin dose errors to possible adverse blood glucose outcomes when glucose meters are miscoded. Methods Five sets of glucose meters were used. Two sets of meters were autocoded and therefore could not be miscoded, and three sets required manual coding. Two of each set of manually coded meters were deliberately miscoded, and one from each set was properly coded. Subjects (n = 116) had finger stick blood glucose obtained at fasting, as well as at 1 and 2 hours after a fixed meal (Boost®; Novartis Medical Nutrition U.S., Basel, Switzerland). Deviations of meter blood glucose results from the reference method (YSI) were used to predict insulin dose errors and resultant blood glucose outcomes based on these deviations. Results Using insulin sensitivity data, it was determined that, given an actual blood glucose of 150–400 mg/dl, an error greater than +40 mg/dl would be required to calculate an insulin dose sufficient to produce a blood glucose of less than 70 mg/dl. Conversely, an error less than or equal to -70 mg/dl would be required to derive an insulin dose insufficient to correct an elevated blood glucose to less than 180 mg/dl. For miscoded meters, the estimated probability to produce a blood glucose reduction to less than or equal to 70 mg/dl was 10.40%. The corresponding probabilities for autocoded and correctly coded manual meters were 2.52% (p < 0.0001) and 1.46% (p < 0.0001), respectively. Furthermore, the errors from miscoded meters were large enough to produce a calculated blood glucose outcome less than or equal to 50 mg/dl in 42 of 833 instances. Autocoded meters produced zero (0) outcomes less than or equal to 50 mg/dl out of 279 instances, and correctly coded manual meters produced 1 of 416. Conclusions Improperly coded blood glucose meters present the potential for insulin dose errors and resultant clinically significant hypoglycemia or hyperglycemia. Patients should be instructed and periodically reinstructed in the proper use of blood glucose meters, particularly for meters that require coding. PMID:19885229

  20. 10 CFR 835.703 - Other monitoring records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....1102(d); (b) Results of monitoring used to determine individual occupational dose from external and internal sources; (c) Results of monitoring for the release and control of material and equipment as...

  1. Maywood Interim Storage Site annual environmental report for calendar year 1991, Maywood, New Jersey. Formerly Utilized Sites Remedial Action Program (FUSRAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    This document describes the environmental monitoring program at the Maywood Interim Storage Site (MISS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring of MISS began in 1984 when congress added the site to the US Department of Energy`s (DOE) Formerly Utilized Sites Remedial Action Program (FUSRAP). FUSRAP is a DOE program to identify and decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation`s atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at MISS includesmore » sampling networks for radon and thoron concentrations in air; external gamma radiation-exposure; and total uranium, radium-226, radium-228, thorium-232, and thorium-230 concentrations in surface water, sediment, and groundwater. Additionally, several nonradiological parameters are measured in surface water, sediment, and groundwater. Monitoring results are compared with applicable Environmental Protection Agency standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE orders. Environmental standards are established to protect public health and the environment.« less

  2. Maywood Interim Storage Site annual environmental report for calendar year 1991, Maywood, New Jersey. [Maywood Interim Storage Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1992-09-01

    This document describes the environmental monitoring program at the Maywood Interim Storage Site (MISS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring of MISS began in 1984 when congress added the site to the US Department of Energy's (DOE) Formerly Utilized Sites Remedial Action Program (FUSRAP). FUSRAP is a DOE program to identify and decontaminate or otherwise control sites where residual radioactive materials remain from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at MISS includesmore » sampling networks for radon and thoron concentrations in air; external gamma radiation-exposure; and total uranium, radium-226, radium-228, thorium-232, and thorium-230 concentrations in surface water, sediment, and groundwater. Additionally, several nonradiological parameters are measured in surface water, sediment, and groundwater. Monitoring results are compared with applicable Environmental Protection Agency standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE orders. Environmental standards are established to protect public health and the environment.« less

  3. Hazelwood Interim Storage Site annual environmental report for calendar year 1991, Hazelwood, Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    This document describes the environmental monitoring program at the Hazelwood Interim Storage Site (HISS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring of HISS began in 1984 when the site was assigned to the US Department of Energy (DOE) as part of the decontamination research and development project authorized by Congress under the 1984 Energy and Water Development Appropriations Act. DOE placed responsibility for HISS under the Formerly Utilized Sites Remedial Action Program (FUSRAP), a DOE program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of themore » nation`s atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at HISS includes sampling networks for radon concentrations in air; external gamma radiation exposure; and radium-226, thorium-230, and total uranium concentrations in surface water, sediment, and groundwater. Additionally, several nonradiological parameters are measured in groundwater. Monitoring results are compared with applicable Environmental Protection Agency standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE orders. Environmental standards and DCGs are established to protect public health and the environment.« less

  4. Anesthesia for ambulatory anorectal surgery.

    PubMed

    Gudaityte, Jūrate; Marchertiene, Irena; Pavalkis, Dainius

    2004-01-01

    The prevalence of minor anorectal diseases is 4-5% of adult Western population. Operations are performed on ambulatory or 24-hour stay basis. Requirements for ambulatory anesthesia are: rapid onset and recovery, ability to provide quick adjustments during maintenance, lack of intraoperative and postoperative side effects, and cost-effectiveness. Anorectal surgery requires deep levels of anesthesia. The aim is achieved with 1) regional blocks alone or in combination with monitored anesthesia care or 2) deep general anesthesia, usually with muscle relaxants and tracheal intubation. Modern general anesthetics provide smooth, quickly adjustable anesthesia and are a good choice for ambulatory surgery. Popular regional methods are: spinal anesthesia, caudal blockade, posterior perineal blockade and local anesthesia. The trend in regional anesthesia is lowering the dose of local anesthetic, providing selective segmental block. Adjuvants potentiating analgesia are recommended. Postoperative period may be complicated by: 1) severe pain, 2) urinary retention due to common nerve supply, and 3) surgical bleeding. Complications may lead to hospital admission. In conclusion, novel general anesthetics are recommended for ambulatory anorectal surgery. Further studies to determine an optimal dose and method are needed in the group of regional anesthesia.

  5. Use of iodine for water disinfection: iodine toxicity and maximum recommended dose.

    PubMed Central

    Backer, H; Hollowell, J

    2000-01-01

    Iodine is an effective, simple, and cost-efficient means of water disinfection for people who vacation, travel, or work in areas where municipal water treatment is not reliable. However, there is considerable controversy about the maximum safe iodine dose and duration of use when iodine is ingested in excess of the recommended daily dietary amount. The major health effect of concern with excess iodine ingestion is thyroid disorders, primarily hypothyroidism with or without iodine-induced goiter. A review of the human trials on the safety of iodine ingestion indicates that neither the maximum recommended dietary dose (2 mg/day) nor the maximum recommended duration of use (3 weeks) has a firm basis. Rather than a clear threshold response level or a linear and temporal dose-response relationship between iodine intake and thyroid function, there appears to be marked individual sensitivity, often resulting from unmasking of underlying thyroid disease. The use of iodine for water disinfection requires a risk-benefit decision based on iodine's benefit as a disinfectant and the changes it induces in thyroid physiology. By using appropriate disinfection techniques and monitoring thyroid function, most people can use iodine for water treatment over a prolonged period of time. PMID:10964787

  6. Emergency Dosimetry Using Ceramic Components in Personal Electronic Devices

    NASA Astrophysics Data System (ADS)

    Kouroukla, E. C.; Bailiff, I. K.; Terry, I.

    2014-02-01

    The rapid assessment of radiation dose to members of the public exposed to significant levels of ionizing radiation during a radiological incident presents a significant difficulty in the absence of planned radiation monitoring. However, within most personal electronic devices components such as resistors with alumina substrates can be found that have potentially suitable properties as solid state dosimeters using luminescence measurement techniques. The suitability of several types of ceramic-based components (e.g., resonators, inductors and resistors) has been previously examined using optically stimulated luminescence (OSL) and thermoluminescence (TL) techniques to establish their basic characteristics for the retrospective determination of absorbed dose. In this paper, we present results obtained with aluminum oxide surface mount resistors extracted from mobile phones that further extend this work. Very encouraging results have been obtained related to the measurement of luminescence sensitivity, dose response, reusability, limit of detection, signal reproducibility and known-dose recovery. However, the alumina exhibits a rapid loss of the latent luminescence signal with time following irradiation attributed to athermal (or anomalous) fading. The issues related to obtaining a reliable correction protocol for this loss and the detailed examinations required of the fading behavior are discussed.

  7. Design of a tracking device for on-line dose monitoring in hadrontherapy

    NASA Astrophysics Data System (ADS)

    Battistoni, G.; Collamati, F.; De Lucia, E.; Faccini, R.; Marafini, M.; Mattei, I.; Muraro, S.; Paramatti, R.; Patera, V.; Pinci, D.; Rucinski, A.; Russomando, A.; Sarti, A.; Sciubba, A.; Solfaroli Camillocci, E.; Toppi, M.; Traini, G.; Voena, C.

    2017-02-01

    Hadrontherapy is a technique for cancer treatment that exploits ion beams (mostly protons and carbons). A critical issue is the accuracy that is achievable when monitoring the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a tracking device, developed in the framework of the INSIDE project [1], capable of monitoring in real time the longitudinal profile of the dose delivered in the patient. This is possible by detecting the secondary particles produced by the interaction of the beam in the tissues. The position of the Bragg peak can be correlated to the charged particles emission point distribution measurement. The tracking device will be able to provide a fast response on the dose pattern by tracking the secondary charged fragments. The tracks are detected using 6 planes of scintillating fibers, providing the 3D coordinates of the track intersection with each plane. The fibers planes are followed by a plastic scintillator and by a small calorimeter built with a pixelated Lutetium Fine Silicate (LFS) crystal. A complete detector simulation, followed by the event reconstruction, has been performed to determine the achievable monitoring spatial resolution.

  8. Managing iron deficiency and iron deficiency anemia in inflammatory bowel disease. The results of the "Gestiona hierro-EII" survey.

    PubMed

    Casellas Jordá, Francesc; Vera Mendoza, Isabel; Barreiro-de Acosta, Manuel; Vázquez Morón, Juan María; López Román, Javier; Júdez Gutiérrez, Javier

    2018-03-01

    iron deficiency anemia is a common and very relevant manifestation of inflammatory bowel disease (IBD). Although clinical practice guidelines have been published and updated on this subject, the management in the daily practice of this complication is far from optimal. to determine the actual management, needs and limitations of anemia in IBD by means of a survey of gastroenterology specialists. a self-administered telematic survey was carried out between April and May 2017 and was sent to SEPD members. The survey included four sections: participant demographics, monitoring, treatment and limitations/needs. a total of 122 evaluable surveys were received from all Spanish autonomous communities. Iron deficiency anemia is considered as a frequent manifestation of IBD and is monitored in all patients via the measurement of hemoglobin and ferritin. In the case of anemia, the survey respondents found it necessary to rule out the presence of IBD activity. However, only 14.8% prescribed intravenous iron when IBD was active. The required dose of intravenous iron is mainly calculated according to patient needs but only 33.1% of clinicians infused doses of 1 g or more. the "Gestiona Hierro EII" survey on the management of anemia in IBD demonstrated a high quality of care, even though some aspects need to be improved. These included the prescription of intravenous iron for patients with disease activity, the use of high-dose intravenous iron and the implementation of algorithms into clinical practice.

  9. Dosimetric quality, accuracy, and deliverability of modulated radiotherapy treatments for spinal metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kairn, Tanya, E-mail: t.kairn@gmail.com; School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Brisbane; Papworth, Daniel

    2016-10-01

    Cancer often metastasizes to the vertebra, and such metastases can be treated successfully using simple, static posterior or opposed-pair radiation fields. However, in some cases, including when re-irradiation is required, spinal cord avoidance becomes necessary and more complex treatment plans must be used. This study evaluated 16 sample intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans designed to treat 6 typical vertebral and paraspinal volumes using a standard prescription, with the aim of investigating the advantages and limitations of these treatment techniques and providing recommendations for their optimal use in vertebral treatments. Treatment plan quality and beammore » complexity metrics were evaluated using the Treatment And Dose Assessor (TADA) code. A portal-imaging–based quality assurance (QA) system was used to evaluate treatment delivery accuracy, and radiochromic film measurements were used to provide high-resolution verification of treatment plan dose accuracy, especially in the steep dose gradient regions between each vertebral target and spinal cord. All treatment modalities delivered approximately the same doses and the same levels of dose heterogeneity to each planning target volume (PTV), although the minimum PTV doses in the vertebral plans were substantially lower than the prescription, because of the requirement that the plans meet a strict constraint on the dose to the spinal cord and cord planning risk volume (PRV). All plans met required dose constraints on all organs at risk, and all measured PTV-cord dose gradients were steeper than planned. Beam complexity analysis suggested that the IMRT treatment plans were more deliverable (less complex, leading to greater QA success) than the VMAT treatment plans, although the IMRT plans also took more time to deliver. The accuracy and deliverability of VMAT treatment plans were found to be substantially increased by limiting the number of monitor units (MU) per beam at the optimization stage, and thereby limiting beam modulation complexity. The VMAT arcs that were optimized with MU limitation had higher QA pass rates as well as higher modulation complexity scores (less complexity), lower modulation indices (less modulation), lower MU per beam, larger beam segments, and fewer small apertures than the VMAT arcs that were optimized without MU limitation. It is recommended that VMAT treatments for vertebral volumes, where the PTV abuts or surrounds the spinal cord, should be optimized with MU limitation. IMRT treatments may be preferable to the VMAT treatments, for dosimetry and deliverability reasons, but may be inappropriate for some patients because of their increased treatment delivery time.« less

  10. Does initial dosing of levothyroxine in infants with congenital hypothyroidism lead to frequent dose adjustments secondary to iatrogenic hyperthyroidism on follow-up?

    PubMed

    Craven, Meghan; Frank, Graeme R

    2018-06-27

    Congenital hypothyroidism (CH) is the most common preventable cause of intellectual disability. The recommended starting dose of levothyroxine (LT4) is between 10 and 15 μg/kg, an extremely wide range. We hypothesized that a sizable proportion of newborns treated for CH at the higher end of the dosage range become biochemically hyperthyroid at a follow-up visit. This study is a retrospective chart review of infants with CH between 2002 and 2012. Of the 104 patients included in this analysis, the average age at diagnosis was 11 days and the average starting dose of LT4 was 12±2.5 μg/kg. At follow-up, 36.5% required a dose reduction because of iatrogenic hyperthyroxinemia, 51% required no dose adjustment and 12.5% required a dose increase due to an elevated thyroid stimulating hormone (TSH). The starting doses of LT4 for those requiring a dose reduction, those not requiring an adjustment and those requiring an increase in the dose were 13.2±2.4, 11.5±2.1 and 10.3±2.6 μg/kg/day, respectively (p≤0.0001). Of the 34% of infants treated with an initial dose of >12.5 μg/day, 57.1% required a dose reduction at follow-up, compared to 26.1% of those whose initial starting dose was ≤12.5 μg/kg/day (p=0.007). Following the guidelines for initiating therapy for CH, 36.5% of the infants required a dose reduction for iatrogenic hyperthyroxinemia. These infants received a higher dose of LT4 than the infants who either required no adjustment or required an increase in the dose. A narrower range for initial dosing in CH may be appropriate.

  11. [Evaluation of an Experimental Production Wireless Dose Monitoring System for Radiation Exposure Management of Medical Staff].

    PubMed

    Fujibuchi, Toshioh; Murazaki, Hiroo; Kuramoto, Taku; Umedzu, Yoshiyuki; Ishigaki, Yung

    2015-08-01

    Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray. The energy, dose rate, and pulse fluoroscopy dependence were evaluated as the basic characteristics of this system for diagnostic X-ray using a fully digital fluoroscopy system. The error of 1 cm dose equivalent rate was less than 15% from 35.1 keV to 43.2 keV with energy correction using metal filter. It was possible to accurately measure the dose rate dependence of this system, which was highly linear until 100 μSv/h. This system showed a constant response to the pulse fluoroscopy. This system will become useful wireless dosimeter for the individual exposure management by improving the high dose rate and the energy characteristics.

  12. Occlusion dose monitoring in amblyopia therapy: status, insights, and future directions.

    PubMed

    Stewart, Catherine E; Moseley, Merrick J; Georgiou, Pantelis; Fielder, Alistair R

    2017-10-01

    Occlusion therapy remains the mainstay treatment of amblyopia, but its outcome is not assured or universally excellent. Many factors are known to influence treatment outcome, among which compliance is foremost. The occlusion dose monitor (ODM) removes one variable from the treatment equation, because it records the occlusion actually received by-rather than prescribed for-the child. Improvement observed can thus be quantitatively related to the patching received. This review summarizes the insights the ODM has provided to date particularly in elucidating the dose-response relationship. We are entering the era of personalized ophthalmology in which treatments will be tailored to the needs of the individual child and facilitated by the use of wearable monitors. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  13. Individual dose monitoring of the nuclear medicine departments staff controlled by Central Laboratory for Radiological Protection.

    PubMed

    Szewczak, Kamil; Jednoróg, Sławomir; Krajewski, Paweł

    2013-01-01

    Presented paper describes the results of the individual doses measurements for ionizing radiation, carried out by the Laboratory of Individual and Environmental Doses Monitoring (PDIS) of the Central Laboratory for Radiological Protection in Warsaw (CLOR) for the medical staff employees in several nuclear medicine (NM) departments across Poland. In total there are48 NM departments in operation in Poland [1] (consultation in Nuclear Atomic Agency). Presented results were collected over the period from January 2011 to December 2011 at eight NM departments located in Krakow, Warszawa (two departments), Rzeszow (two departments), Opole, Przemysl and Gorzow Wielkopolski. For radiation monitoring three kinds of thermo luminescence dosimeters (TLD) were used. The first TLD h collected information about whole body (C) effective dose, the second dosimeter was mounted in the ring (P) meanwhile the third on the wrist (N) of the tested person. Reading of TLDs was performed in quarterly periods. As a good approximation of effective and equivalent dose assessment of operational quantities both the individual dose equivalent Hp(10) and the Hp(0.07) were used. The analysis of the data was performed using two methods The first method was based on quarterly estimations of Hp(10)q and Hp(0.07)q while the second measured cumulative annual doses Hp(10)a and Hp(0.07)a. The highest recorded value of the radiation dose for quarterly assessments reached 24.4 mSv and was recorded by the wrist type dosimeter worn by a worker involved in source preparation procedure. The mean values of Hp(10)q(C type dosimeter) and Hp(0.07)q (P and N type dosimeter) for all monitored departments were respectively 0.46 mSv and 3.29 mSv. There was a strong correlation between the performed job and the value of the received dose. The highest doses always were absorbed by those staff members who were involved in sources preparation. The highest annual cumulative dose for a particular worker in the considered time period was 4.22 mSv for Hp(10)a and 67.7 mSv for Hp(0.07)a. In 2011 no case of exceeding the allowed dose limits was noted.

  14. Management of early renal anaemia: diagnostic work-up, iron therapy, epoetin therapy.

    PubMed

    Van Wyck, D B

    2000-01-01

    Effective management of early anaemia in the course of chronic renal insufficiency requires the following: (i) implementing an efficient diagnostic strategy to exclude common contributing factors; (ii) initiating epoetin therapy for the majority of patients; for and (iii) ensuring adequate iron supply erythropoiesis. Diagnostic inquiry is warranted whenever the haemoglobin concentration is below the normal range adjusted for age and gender. The most efficient diagnostic approach is to assume erythropoietin deficiency, exclude iron deficiency, and pursue further diagnostic tests only when red-cell indices are abnormal or when leukopenia or thrombocytopenia are also present. Macrocytosis should prompt an inquiry into alcoholism, B12 deficiency, or folate deficiency. Microcytosis suggests iron deficiency or thalassaemia. Associated cytopenias raise the possibility of alcohol toxicity, pernicious anaemia, malignancy, or myelodysplastic syndrome. Epoetin therapy is warranted whenever the haemoglobin concentration has fallen below 10.0 g/dl. To initiate therapy prior to dialysis, epoetin should be administered at an average dose of 100 IU/kg/week (80-120 IU/kg/week, 50-150 IU/kg/ week) by subcutaneous injection. Haemoglobin concentration should be monitored every 2 weeks and the epoetin dose adjusted by increments or decrements of 25% to maintain a rate of rise of haemoglobin concentration of 0.2-0.6 g/dl (0.3 0.6 g/dl/week, 0.2-0.5 g/dl/week). When the target range is achieved, the dose of epoetin should be continually adjusted to maintain a stable haemoglobin concentration. Transferrin saturation and ferritin concentration should be monitored monthly, and sufficient iron provided to maintain transferrin saturation above 20%. The lower the haemoglobin concentration, the greater the likelihood that future intravenous iron will be required. Oral iron supplements should be avoided, since they are costly, ineffective, and troublesome to patients. Finally, a blunted therapeutic response to epoetin therapy provides important diagnostic information and gnostic inquiry.

  15. Total dural irradiation: RapidArc versus static-field IMRT: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, Paul J., E-mail: paulj.kelly@hse.ie; Mannarino, Edward; Lewis, John Henry

    2012-07-01

    The purpose of this study was to compare conventional fixed-gantry angle intensity-modulated radiation therapy (IMRT) with RapidArc for total dural irradiation. We also hypothesize that target volume-individualized collimator angles may produce substantial normal tissue sparing when planning with RapidArc. Five-, 7-, and 9-field fixed-gantry angle sliding-window IMRT plans were generated for comparison with RapidArc plans. Optimization and normal tissue constraints were constant for all plans. All plans were normalized so that 95% of the planning target volume (PTV) received at least 100% of the dose. RapidArc was delivered using 350 Degree-Sign clockwise and counterclockwise arcs. Conventional collimator angles of 45more » Degree-Sign and 315 Degree-Sign were compared with 90 Degree-Sign on both arcs. Dose prescription was 59.4 Gy in 33 fractions. PTV metrics used for comparison were coverage, V{sub 107}%, D1%, conformality index (CI{sub 95}%), and heterogeneity index (D{sub 5}%-D{sub 95}%). Brain dose, the main challenge of this case, was compared using D{sub 1}%, Dmean, and V{sub 5} Gy. Dose to optic chiasm, optic nerves, globes, and lenses was also compared. The use of unconventional collimator angles (90 Degree-Sign on both arcs) substantially reduced dose to normal brain. All plans achieved acceptable target coverage. Homogeneity was similar for RapidArc and 9-field IMRT plans. However, heterogeneity increased with decreasing number of IMRT fields, resulting in unacceptable hotspots within the brain. Conformality was marginally better with RapidArc relative to IMRT. Low dose to brain, as indicated by V5Gy, was comparable in all plans. Doses to organs at risk (OARs) showed no clinically meaningful differences. The number of monitor units was lower and delivery time was reduced with RapidArc. The case-individualized RapidArc plan compared favorably with the 9-field conventional IMRT plan. In view of lower monitor unit requirements and shorter delivery time, RapidArc was selected as the optimal solution. Individualized collimator angle solutions should be considered by RapidArc dosimetrists for OARs dose reduction. RapidArc should be considered as a treatment modality for tumors that extensively involve in the skull, dura, or scalp.« less

  16. A new scheme for biomonitoring heavy metal concentrations in semi-natural wetlands.

    PubMed

    Batzias, A F; Siontorou, C G

    2008-10-30

    This work introduces a semi-natural wetland biomonitoring framework for heavy metal concentrations based on a robust dynamic integration between biological assemblages and relevant biosensors. The cooperative/synergistic scheme developed minimizes uncertainty and monitoring costs and increases reliability of pollution control and abatement. Attention is given to establishing a fully functioning and reliable network approach for monitoring inflows and achieving dose-response relations and calibration of biomonitoring species. The biomonitoring network initially consists of both, biosensors and species, as a validation phase in each wetland of the surveillance area; once the species monitoring efficiency is verified by the biosensors, the biosensor network moves to the next wetland and so on, following a circular pattern until all area wetlands have a fully functional natural monitoring scheme. By means of species recalibration with periodic revisiting of the biosensors, the scheme progressively reaches a quasi steady-state (including seasonality), thus ensuring reliability and robustness. This framework, currently pilot-tested in Voiotia, Greece, for assessing chromium levels, has been built to cover short-, medium- and long-term monitoring requirements. The results gathered so far, support the employment of the proposed scheme in heavy metal monitoring, and, further, arise the need for volunteer involvement to achieve long-term viability.

  17. Correlation between the single, high dose of ingested baclofen and clinical symptoms.

    PubMed

    Anand, Jacek Sein; Zając, Maciej; Waldman, Wojciech; Wojtyła, Andrzej; Biliński, Przemysław; Jaworska-Łuczak, Barbara

    2017-12-23

    Baclofen is a drug used mainly to treat muscle spasticity. Its overdose can lead to life-threatening clinical symptoms, including acute respiratory failure requiring mechanical ventilation. The aim of this study was to assess the prevalence of selected clinical symptoms associated with baclofen poisoning comparing to an ingested dose. 60 cases of oral baclofen poisoning were analyzed. Gender, age distribution, and correlation between the dose of ingested baclofen were studied, as well as and following clinical parameters: degree of altered consciousness, heart rate, blood pressure, presence of acute respiratory failure, duration of mechanical ventilation, and presence of psychotic symptoms. The study found statistically significant correlations between dosage of ingested baclofen and presence of acute respiratory failure, as well as duration of mechanical ventilation. No statistically significant correlations were found between the dose of ingested baclofen and presence of hypertension, bradycardia, acute psychotic symptoms, or level of consciousness disturbance. However, it was found that patients who suffered from hypertension, bradycardia, and altered mental status ingested a larger dose of baclofen. There is a statistically significant correlation between the dose of ingested baclofen and the presence of acute respiratory failure, and duration of mechanical ventilation. Patients who have taken a single dose of baclofen of 200 mg, or higher, should be managed in centres able to provide continuous monitoring of life functions. Those with a higher level of a single dose of baclofen ingestion (>500 mg), should be hospitalized in a Toxicology Unit or Intensive Care Unit able to provide airway support and mechanical ventilation.

  18. Is volumetric modulated arc therapy with constant dose rate a valid option in radiation therapy for head and neck cancer patients?

    PubMed

    Didona, Annamaria; Lancellotta, Valentina; Zucchetti, Claudio; Panizza, Bianca Moira; Frattegiani, Alessandro; Iacco, Martina; Di Pilato, Anna Concetta; Saldi, Simonetta; Aristei, Cynthia

    2018-01-01

    Intensity-modulated radiotherapy (IMRT) improves dose distribution in head and neck (HN) radiation therapy. Volumetric-modulated arc therapy (VMAT), a new form of IMRT, delivers radiation in single or multiple arcs, varying dose rates (VDR-VMAT) and gantry speeds, has gained considerable attention. Constant dose rate VMAT (CDR-VMAT) associated with a fixed gantry speed does not require a dedicated linear accelerator like VDR-VMAT. The present study explored the feasibility, efficiency and delivery accuracy of CDR-VMAT, by comparing it with IMRT and VDR-VMAT in treatment planning for HN cancer. Step and shoot IMRT (SS-IMRT), CDR-VMAT and VDR-VMAT plans were created for 15 HN cancer patients and were generated by Pinnacle 3 TPS (v 9.8) using 6 MV photon energy. Three PTVs were defined to receive respectively prescribed doses of 66 Gy, 60 Gy and 54 Gy, in 30 fractions. Organs at risk (OARs) included the mandible, spinal cord, brain stem, parotids, salivary glands, esophagus, larynx and thyroid. SS-IMRT plans were based on 7 co-planar beams at fixed gantry angles. CDR-VMAT and VDR-VMAT plans, generated by the SmartArc module, used a 2-arc technique: one clockwise from 182° to 178° and the other one anti-clockwise from 178° to 182°. Comparison parameters included dose distribution to PTVs ( D mean , D 2% , D 50% , D 95% , D 98% and Homogeneity Index), maximum or mean doses to OARs, specific dose-volume data, the monitor units and treatment delivery times. Compared with SS-IMRT, CDR-VMAT significantly reduced the maximum doses to PTV1 and PTV2 and significantly improved all PTV3 parameters, except D 98% and D 95% . It significantly spared parotid and submandibular glands and was associated with a lower D mean to the larynx. Compared with VDR-VMAT, CDR-VMAT was linked to a significantly better D mean , to the PTV3 but results were worse for the parotids, left submandibular gland, esophagus and mandible. Furthermore, the D mean to the larynx was also worse. Compared with SS-IMRT and VDR-VMAT, CDR-VMAT was associated with higher average monitor unit values and significantly shorter average delivery times. CDR-VMAT appeared to be a valid option in Radiation Therapy Centers that lack a dedicated linear accelerator for volumetric arc therapy with variable dose-rates and gantry velocities, and are unwilling or unable to sanction major expenditure at present but want to adopt volumetric techniques.

  19. A Quasi-Experiment To Study the Impact of Vancomycin Area under the Concentration-Time Curve-Guided Dosing on Vancomycin-Associated Nephrotoxicity

    PubMed Central

    Finch, Natalie A.; Zasowski, Evan J.; Murray, Kyle P.; Mynatt, Ryan P.; Zhao, Jing J.; Yost, Raymond; Pogue, Jason M.

    2017-01-01

    ABSTRACT Evidence suggests that maintenance of vancomycin trough concentrations at between 15 and 20 mg/liter, as currently recommended, is frequently unnecessary to achieve the daily area under the concentration-time curve (AUC24) target of ≥400 mg · h/liter. Many patients with trough concentrations in this range have AUC24 values in excess of the therapeutic threshold and within the exposure range associated with nephrotoxicity. On the basis of this, the Detroit Medical Center switched from trough concentration-guided dosing to AUC-guided dosing to minimize potentially unnecessary vancomycin exposure. The primary objective of this analysis was to assess the impact of this intervention on vancomycin-associated nephrotoxicity in a single-center, retrospective quasi-experiment of hospitalized adult patients receiving intravenous vancomycin from 2014 to 2015. The primary analysis compared the incidence of nephrotoxicity between patients monitored by assessment of the AUC24 and those monitored by assessment of the trough concentration. Multivariable logistic and Cox proportional hazards regression examined the independent association between the monitoring strategy and nephrotoxicity. Secondary analysis compared vancomycin exposures (total daily dose, AUC, and trough concentrations) between monitoring strategies. Overall, 1,280 patients were included in the analysis. After adjusting for severity of illness, comorbidity, duration of vancomycin therapy, and concomitant receipt of nephrotoxins, AUC-guided dosing was independently associated with lower nephrotoxicity by both logistic regression (odds ratio, 0.52; 95% confidence interval [CI], 0.34 to 0.80; P = 0.003) and Cox proportional hazards regression (hazard ratio, 0.53; 95% CI, 0.35 to 0.78; P = 0.002). AUC-guided dosing was associated with lower total daily vancomycin doses, AUC values, and trough concentrations. Vancomycin AUC-guided dosing was associated with reduced nephrotoxicity, which appeared to be a result of reduced vancomycin exposure. PMID:28923869

  20. A Quasi-Experiment To Study the Impact of Vancomycin Area under the Concentration-Time Curve-Guided Dosing on Vancomycin-Associated Nephrotoxicity.

    PubMed

    Finch, Natalie A; Zasowski, Evan J; Murray, Kyle P; Mynatt, Ryan P; Zhao, Jing J; Yost, Raymond; Pogue, Jason M; Rybak, Michael J

    2017-12-01

    Evidence suggests that maintenance of vancomycin trough concentrations at between 15 and 20 mg/liter, as currently recommended, is frequently unnecessary to achieve the daily area under the concentration-time curve (AUC 24 ) target of ≥400 mg · h/liter. Many patients with trough concentrations in this range have AUC 24 values in excess of the therapeutic threshold and within the exposure range associated with nephrotoxicity. On the basis of this, the Detroit Medical Center switched from trough concentration-guided dosing to AUC-guided dosing to minimize potentially unnecessary vancomycin exposure. The primary objective of this analysis was to assess the impact of this intervention on vancomycin-associated nephrotoxicity in a single-center, retrospective quasi-experiment of hospitalized adult patients receiving intravenous vancomycin from 2014 to 2015. The primary analysis compared the incidence of nephrotoxicity between patients monitored by assessment of the AUC 24 and those monitored by assessment of the trough concentration. Multivariable logistic and Cox proportional hazards regression examined the independent association between the monitoring strategy and nephrotoxicity. Secondary analysis compared vancomycin exposures (total daily dose, AUC, and trough concentrations) between monitoring strategies. Overall, 1,280 patients were included in the analysis. After adjusting for severity of illness, comorbidity, duration of vancomycin therapy, and concomitant receipt of nephrotoxins, AUC-guided dosing was independently associated with lower nephrotoxicity by both logistic regression (odds ratio, 0.52; 95% confidence interval [CI], 0.34 to 0.80; P = 0.003) and Cox proportional hazards regression (hazard ratio, 0.53; 95% CI, 0.35 to 0.78; P = 0.002). AUC-guided dosing was associated with lower total daily vancomycin doses, AUC values, and trough concentrations. Vancomycin AUC-guided dosing was associated with reduced nephrotoxicity, which appeared to be a result of reduced vancomycin exposure. Copyright © 2017 American Society for Microbiology.

  1. Colonie Interim Storage Site annual environmental report for calendar year 1991, Colonie, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    This document describes the environmental monitoring program at the Colonie Interim Storage Site (CISS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring at CISS began in 1984 when Congress added the site to the US Department of Energy's Formerly Utilized Sites Remedial Action Program. CISS property and surrounding areas were radioactively contaminated by operations conducted by National Lead Industries, which manufactured various components from uranium and thorium from 1958 to 1984. The environmental monitoring program at CISS includes sampling networks for external gamma radiation exposure and for radium-226, thorium-232, and total uranium concentrations inmore » surface water, sediment, and groundwater. Additionally, several nonradiological parameters are measured in groundwater. In 1992 the program will also include sampling networks for radioactive and chemical contaminants in stormwater to meet permit application requirements under the Clean Water Act. Monitoring results are compared with applicable Environmental Protection Agency (EPA) standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE.orders. Environmental standards are established to protect public health and the environment. Results of environmental monitoring during 1991 indicate that average concentrations of radioactive contaminants of concern were well below applicable standards and DCGS. Concentrations of some chemical contaminants in groundwater were above-the New York State Department of Environmental Conservation (Class GA) and EPA guidelines for drinking water. The potential annual radiation exposure (excluding background) calculated for a hypothetical maximally exposed individual is 0.23 mrem (milliroentgen equivalent man), which is less than an individual would receive while traveling in an airplane at 12,000 meters (39,000 feet) for one hour.« less

  2. Colonie Interim Storage Site annual environmental report for calendar year 1991, Colonie, New York. Formerly Utilized Sites Remedial Action Program (FUSRAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    This document describes the environmental monitoring program at the Colonie Interim Storage Site (CISS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring at CISS began in 1984 when Congress added the site to the US Department of Energy`s Formerly Utilized Sites Remedial Action Program. CISS property and surrounding areas were radioactively contaminated by operations conducted by National Lead Industries, which manufactured various components from uranium and thorium from 1958 to 1984. The environmental monitoring program at CISS includes sampling networks for external gamma radiation exposure and for radium-226, thorium-232, and total uranium concentrations inmore » surface water, sediment, and groundwater. Additionally, several nonradiological parameters are measured in groundwater. In 1992 the program will also include sampling networks for radioactive and chemical contaminants in stormwater to meet permit application requirements under the Clean Water Act. Monitoring results are compared with applicable Environmental Protection Agency (EPA) standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE.orders. Environmental standards are established to protect public health and the environment. Results of environmental monitoring during 1991 indicate that average concentrations of radioactive contaminants of concern were well below applicable standards and DCGS. Concentrations of some chemical contaminants in groundwater were above-the New York State Department of Environmental Conservation (Class GA) and EPA guidelines for drinking water. The potential annual radiation exposure (excluding background) calculated for a hypothetical maximally exposed individual is 0.23 mrem (milliroentgen equivalent man), which is less than an individual would receive while traveling in an airplane at 12,000 meters (39,000 feet) for one hour.« less

  3. Radiation dose-rate meter using an energy-sensitive counter

    DOEpatents

    Kopp, Manfred K.

    1988-01-01

    A radiation dose-rate meter is provided which uses an energy-sensitive detector and combines charge quantization and pulse-rate measurement to monitor radiation dose rates. The charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to the dose-rate.

  4. Self-Monitoring in Weight Loss: A Systematic Review of the Literature

    PubMed Central

    Wang, Jing; Sevick, Mary Ann

    2011-01-01

    Self-monitoring is the centerpiece of behavioral weight loss intervention programs. This article presents a systematic review of the literature on three components of self-monitoring in behavioral weight loss studies: diet, exercise and self-weighing. This review included articles that were published between 1993 and 2009 that reported on the relationship between weight loss and these self-monitoring strategies. Of the 22 studies identified, 14 focused on dietary self-monitoring, one on self-monitoring exercise and six on self-weighing. A wide array of methods was used to perform self-monitoring; the paper diary was used most often. Adherence to self-monitoring was reported most frequently as the number of diaries completed or the frequency of log-ins or reported weights. The use of technology, which included the Internet, personal digital assistants and electronic digital scales were reported in five studies. Descriptive designs were used in the earlier studies while more recent reports involved prospective studies and randomized trials that examined the effect of self-monitoring on weight loss. A significant association between self-monitoring and weight loss was consistently found; however, the level of evidence was weak because of methodological limitations. The most significant limitations of the reviewed studies were the homogenous samples and reliance on self-report. In all but two studies, the samples were predominantly White and female. This review highlights the need for studies in more diverse populations, for objective measures of adherence to self-monitoring, and for studies that establish the required dose of self-monitoring for successful outcomes. PMID:21185970

  5. Monitoring of unfractionated heparin with rotational thrombelastometry using the prothrombinase-induced clotting time reagent (PiCT®).

    PubMed

    Schaden, E; Jilch, S; Hacker, S; Schober, A; Kozek-Langenecker, S

    2012-12-24

    To achieve sufficient and safe anticoagulation with unfractionated heparin (UFH) a close and reliable drug monitoring is necessary. In general, the activated partial thromboplastin time (APTT) is used for this purpose. In acute phase response, however, the APTT test procedure might be unreliable e.g. with false low results in the presence of elevated factor VIII. In this so called heparin resistance, measurement of anti-Xa activity is recommended over APTT to avoid potentially harmful dose escalation. A combination of anti-Xa measurement and global hemostatic testing with ROTEM® employing the anti-Xa sensitive PiCT® reagent showed high correlation with enoxaparin levels. This test modification could also be suitable for monitoring UFH. Aim of the study was to evaluate the correlation between PiCT®-ROTEM® and levels of UFH. In this in-vitro study blood samples from healthy volunteers were spiked with UFH and subjected to different ROTEM® tests. There was a linear correlation between UFH level and clotting time (CT) in the PiCT®-ROTEM® test with an excellent correlation coefficient of 0.92. Additional endpoints showed similar results (PiCT®-ROTEM® MaxVel r = -0.85 and PiCT®-ROTEM® t_MaxVel r = 0.88). As a point-of-care applicable tool ROTEM® is immediately at hand. If further clinical studies confirm sensitivity in heparin resistance, PiCT®-ROTEM® could permit rapid UFH dose adjustments especially required in critical illness with acute phase response. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Real-time, aptamer-based tracking of circulating therapeutic agents in living animals

    PubMed Central

    Ferguson, B. Scott; Hoggarth, David A.; Maliniak, Dan; Ploense, Kyle; White, Ryan J.; Woodward, Nick; Hsieh, Kuangwen; Bonham, Andrew J.; Eisenstein, Michael; Kippin, Tod; Plaxco, Kevin W.; Soh, H. Tom

    2014-01-01

    A sensor capable of continuously measuring specific molecules in the bloodstream in vivo would give clinicians a valuable window into patients’ health and their response to therapeutics. Such technology would enable truly personalized medicine, wherein therapeutic agents could be tailored with optimal doses for each patient to maximize efficacy and minimize side effects. Unfortunately, continuous, real-time measurement is currently only possible for a handful of targets, such as glucose, lactose, and oxygen, and the few existing platforms for continuous measurement are not generalizable for the monitoring of other analytes, such as small-molecule therapeutics. In response, we have developed a real-time biosensor capable of continuously tracking a wide range of circulating drugs in living subjects. Our microfluidic electrochemical detector for in vivo continuous monitoring (MEDIC) requires no exogenous reagents, operates at room temperature, and can be reconfigured to measure different target molecules by exchanging probes in a modular manner. To demonstrate the system's versatility, we measured therapeutic in vivo concentrations of doxorubicin (a chemotherapeutic) and kanamycin (an antibiotic) in live rats and in human whole blood for several hours with high sensitivity and specificity at sub-minute temporal resolution. Importantly, we show that MEDIC can also obtain pharmacokineticparameters for individual animals in real-time. Accordingly, just as continuous glucose monitoring technology is currently revolutionizing diabetes care, we believe MEDIC could be a powerful enabler for personalized medicine by ensuring delivery of optimal drug doses for individual patients based on direct detection of physiological parameters. PMID:24285484

  7. Undetected Severe Fetal Myelosuppression following Administration of High-Dose Cytarabine for Acute Myeloid Leukemia: Is More Frequent Surveillance Necessary?

    PubMed Central

    Holland, Marium

    2017-01-01

    Background Cytarabine use during pregnancy carries a 5–7% risk of neonatal cytopenia. We report two cases of fetal myelosuppression following high-dose cytarabine administration for acute myeloid leukemia (AML). Case 1 A 36-year-old G9P6 diagnosed with AML at 21 weeks was monitored for fetal anemia weekly and growth monthly. At 33 weeks (after 2 cycles), BPP was 2/10 and MCA PSV was elevated at 1.51 MoM. Urgent cesarean section was performed. The infant had an initial pH of 6.78 and pancytopenia (hematocrit 13.3%, platelets 3 K/UL, and white blood cell count 2.0 K/UL). Initially transfusion dependent, the neonate had count recovery by 3 weeks. Case 2 A 30-year-old G4P3 with AML at 26 weeks was monitored for fetal anemia twice weekly and growth monthly. At 34 weeks (after cycle 1), she was admitted with neutropenic fever. The fetal MCA PSV was borderline at 1.48 MoM. It improved to 1.38 MoM at 35 weeks but the fetal tracing worsened. At delivery the fetus was found to have a hematocrit of 30%, but with normal platelet and WBC. The fetus did not require any transfusions. Conclusion Cytarabine use during pregnancy may cause neonatal myelosuppression. We recommend monitoring for fetal anemia with MCA Dopplers twice weekly. PMID:29075543

  8. Current status and performance of the BESIII electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Fang, Jian; Wang, Zhigang

    2012-12-01

    The design and construction of the BESIII electromagnetic calorimeter is introduced briefly. Radiation dose of CsI(Tl) crystals is monitored and history graph of integral dose of crystals is showed. LED-fiber system is used for monitoring the EMC light output, and large decrease of light output of several crystals is discussed. BESIII electromagnetic calorimeter works very well and its performance reach the design value.

  9. Preparing for the unexpected: special considerations and complications after sugammadex administration.

    PubMed

    Iwasaki, Hajime; Renew, J Ross; Kunisawa, Takayuki; Brull, Sorin J

    2017-10-17

    Sugammadex, a modified gamma-cyclodextrin, has changed clinical practice of neuromuscular reversal dramatically. With the introduction of this selective relaxant binding agent, rapid and reliable neuromuscular reversal from any depth of block became possible. Sugammadex can reverse neuromuscular blockade without the muscarinic side effects typically associated with the administration of acetylcholinesterase inhibitors. However, what remained unchanged is the incidence of residual neuromuscular blockade. It is known that sugammadex cannot always prevent its occurrence, if appropriate dosing is not chosen based on the level of neuromuscular paralysis prior to administration determined by objective neuromuscular monitoring. Alternatively, excessive doses of sugammadex administered in an attempt to ensure full and sustained reversal may affect the effectiveness of rocuronium in case of immediate reoperation or reintubation. In such emergent scenarios that require onset of rapid and reliable neuromuscular blockade, the summary of product characteristics (package insert) recommends using benzylisoquinolinium neuromuscular blocking agents or a depolarizing agent. However, if rapid intubation is required, succinylcholine has a significant number of side effects, and benzylisoquinolinium agents may not have the rapid onset required. Therefore, prior administration of sugammadex introduces a new set of potential problems that require new solutions. This novel reversal agent thus presents new challenges and anesthesiologists must familiarize themselves with specific issues with its use (e.g., bleeding risk, hypermagnesemia, hypothermia). This review will address sugammadex administration in such special clinical situations.

  10. Sirolimus and tacrolimus trough concentrations and dose requirements after kidney transplantation in relation to CYP3A5 and MDR1 polymorphisms and steroids.

    PubMed

    Mourad, Michel; Mourad, Georges; Wallemacq, Pierre; Garrigue, Valérie; Van Bellingen, Christophe; Van Kerckhove, Valérie; De Meyer, Martine; Malaise, Jacques; Eddour, Djamila Chaib; Lison, Dominique; Squifflet, Jean Paul; Haufroid, Vincent

    2005-10-15

    CYP3A5 and MDR1 polymorphisms have been shown to influence tacrolimus blood concentrations and dose requirements. The aim is to determine whether these polymorphisms also affect sirolimus trough concentrations and dose requirements after kidney transplantation. Eighty-five renal transplant recipients receiving sirolimus were included. Twenty-four were treated with a combined sirolimus-tacrolimus regimen. Eighty-one patients received steroids. Sirolimus and tacrolimus were adjusted to a target therapeutic window. CYP3A5 (intron 3) and MDR1 (exons 12, 21, 26) genotypes were correlated to the adjusted trough concentrations and dose requirements for both sirolimus and tacrolimus. There were no significant correlation between adjusted sirolimus trough concentrations or dose requirements and genetic polymorphisms. In a multiple regression model, adjusted-prednisone dose was involved with a positive or negative effect when considering sirolimus dose requirements or adjusted concentrations, respectively. In the subgroup of patients treated by tacrolimus and sirolimus, adjusted tacrolimus doses were higher in patients carrying at least one CYP3A5 *1 allele (median 0.083 vs. 0.035 mg/kg for CYP3A5*3/*3 patients, P<0.05). Adjusted-prednisolone dose and CYP3A5 polymorphism explained up to 61% of the variability in tacrolimus dose requirements. Unlike tacrolimus, sirolimus adjusted trough concentrations and dose requirements seem not affected by CYP3A5 and MDR1 polymorphisms. Adjusted-prednisone dose has a significant impact on tacrolimus and sirolimus dose requirements.

  11. An accurate derivation of the air dose-rate and the deposition concentration distribution by aerial monitoring in a low level contaminated area

    NASA Astrophysics Data System (ADS)

    Nishizawa, Yukiyasu; Sugita, Takeshi; Sanada, Yukihisa; Torii, Tatsuo

    2015-04-01

    Since 2011, MEXT (Ministry of Education, Culture, Sports, Science and Technology, Japan) have been conducting aerial monitoring to investigate the distribution of radioactive cesium dispersed into the atmosphere after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP), Tokyo Electric Power Company. Distribution maps of the air dose-rate at 1 m above the ground and the radioactive cesium deposition concentration on the ground are prepared using spectrum obtained by aerial monitoring. The radioactive cesium deposition is derived from its dose rate, which is calculated by excluding the dose rate of the background radiation due to natural radionuclides from the air dose-rate at 1 m above the ground. The first step of the current method of calculating the dose rate due to natural radionuclides is calculate the ratio of the total count rate of areas where no radioactive cesium is detected and the count rate of regions with energy levels of 1,400 keV or higher (BG-Index). Next, calculate the air dose rate of radioactive cesium by multiplying the BG-Index and the integrated count rate of 1,400 keV or higher for the area where the radioactive cesium is distributed. In high dose-rate areas, however, the count rate of the 1,365-keV peak of Cs-134, though small, is included in the integrated count rate of 1,400 keV or higher, which could cause an overestimation of the air dose rate of natural radionuclides. We developed a method for accurately evaluating the distribution maps of natural air dose-rate by excluding the effect of radioactive cesium, even in contaminated areas, and obtained the accurate air dose-rate map attributed the radioactive cesium deposition on the ground. Furthermore, the natural dose-rate distribution throughout Japan has been obtained by this method.

  12. Meeting the Needs for Radiation Protection: Diagnostic Imaging.

    PubMed

    Frush, Donald P

    2017-02-01

    Radiation and potential risk during medical imaging is one of the foremost issues for the imaging community. Because of this, there are growing demands for accountability, including appropriate use of ionizing radiation in diagnostic and image-guided procedures. Factors contributing to this include increasing use of medical imaging; increased scrutiny (from awareness to alarm) by patients/caregivers and the public over radiation risk; and mounting calls for accountability from regulatory, accrediting, healthcare coverage (e.g., Centers for Medicare and Medicaid Services), and advisory agencies and organizations as well as industry (e.g., NEMA XR-29, Standard Attributes on CT Equipment Related to Dose Optimization and Management). Current challenges include debates over uncertainty with risks with low-level radiation; lack of fully developed and targeted products for diagnostic imaging and radiation dose monitoring; lack of resources for and clarity surrounding dose monitoring programs; inconsistencies across and between practices for design, implementation and audit of dose monitoring programs; lack of interdisciplinary programs for radiation protection of patients; potential shortages in personnel for these and other consensus efforts; and training concerns as well as inconsistencies for competencies throughout medical providers' careers for radiation protection of patients. Medical care providers are currently in a purgatory between quality- and value-based imaging paradigms, a state that has yet to mature to reward this move to quality-based performance. There are also deficits in radiation expertise personnel in medicine. For example, health physics academic programs and graduates have recently declined, and medical physics residency openings are currently at a third of the number of graduates. However, leveraging solutions to the medical needs will require money and resources, beyond personnel alone. Energy and capital will need to be directed to:• innovative and cooperative cross-disciplinary institutional/practice oversight of and guidance for the use of diagnostic imaging (e.g., radiology, surgical specialties, cardiologists, and intensivists);• initiatives providing practical benchmarks (e.g., dose index registries);• comprehensive (consisting of access, integrity, metrology, analytics, informatics) and effective and efficient dose monitoring programs;• collaboration with industry;• improved use of imaging, such as through decision support combined with evidence-based appropriateness for imaging use;• integration with e-health such as medical records;• education, including information extending beyond the medical imaging community that is relevant to patients, public, and providers and administration;• identification of opportunities for alignment with salient media and advocacy organizations to deliver balanced information regarding medical radiation and risk;• open lines of communication between medical radiation experts and appropriate bodies such as the U.S. Environmental Protection Agency, the U.S. Food and Drug Administration, and the Joint Commission to assure appropriate guidance on documents and actions originating from these organizations; and• increased grant funding to foster translational work that advances understanding of low-level radiation and biological effects.

  13. Soiling of window glass of building façades: a new Dose-Response Function based on the mass of deposited particles

    NASA Astrophysics Data System (ADS)

    Ionescu, Anda; Lefèvre, Roger

    2017-04-01

    Materials used in building façades are subject to different types of weathering, an important one being soiling. The material studied here is the silica-soda-lime glass, used for windows and contemporaneous façades. Glass weathering in a polluted environment, sheltered from rain, is dominated by soiling. This phenomenon can be expressed either by an optical parameter, the haze, or by the mass of Deposited and Neoformed Particles by unit of glass surface (DNPs). By contrast to the haze, which is an optical parameter requiring an expensive technology (spectrophotometry), measuring DNPs is much simpler: the glass sample is weighed before and after exposure and the result, divided by the sample surface. After the development of a previous Dose-Response Function (DRF) expressing soiling evolution through haze, this study focuses on the development of a new DRF for soiling expressed in terms of DNPs mass, sheltered from rain. The development of this DRF follows a statistical approach. The general form proposed for the DRF is: DNPs=A(dose1, dose2, …., dosen).g(t) where g(t) represents the temporal trend obtained from standardized data. Data standardization has been employed in order to obtain a general trend independent of the environmental characteristics of the monitoring site. According to previous studies and physical considerations, the analytical form of the temporal trend g(t) was expressed by a function admitting an horizontal asymptote: the saturation level of soling. Ten monitoring campaigns (performed at different European sites) were used; the longest one runs up to 2102 days and the shortest ones, up to 365 days, with 14 to 5 records, respectively. Two different models were fitted by a non-linear regression: the Hill's model and a decreasing exponential model. Both models performed well (R2 ranging from 0.73 to 0.76) and they were further tested in order to get the final form of the DRF. The amplitude function A was considered as a linear combination of the different doses. A multiple linear regression was then applied to doses multiplied by the temporal trend function g permitting to obtain the regression coefficients of the amplitude function A. Another database was used, containing the monitoring values for SO2, NO2 and PM10 concentrations, as well as temperature and relative humidity, monitored at 19 European sites. The correlation between pollution concentrations was taken into account and led to a selection of pollutants in order to avoid numerical instability in the regression procedure. The meteorological parameters didn't have a statistical impact, so they were not considered as doses. A DRF for DNPs could be established using SO2 and PM10 concentrations and the Hill model for the g(t) trend with a determination coefficient of 0.7. This DRF was then used to plot the annual DNPs evolution from 1500 to 2100 in Paris and compared to the same curve expressed in terms of Haze for the same period. The obtained evolution is comparable and reveals an important peak corresponding to the industrial period.

  14. The benefits of antiepileptic drug (AED) blood level monitoring to complement clinical management of people with epilepsy.

    PubMed

    Stepanova, Daria; Beran, Roy G

    2015-01-01

    Some argue that there is no evidence to support the use of antiepileptic drug (AED) blood level monitoring when treating people with epilepsy (PWE). This paper identifies how AED monitoring can be invaluable in such treatment. SPECIFIC EXAMPLES: (i) Compliance: Antiepileptic drug blood levels often confirm noncompliance rather than adequate seizure control, confirming subtherapeutic levels in PWE attending hospitals due to seizures. Routine monitoring of AED levels may prevent breakthrough seizures by identifying noncompliance and instituting heightened compliance measures before experiencing breakthrough seizures without modifying dosages. For PWE attending hospitals due to seizures, loading with the AED shown to be subtherapeutic may be all that is required. (ii) Cluster seizures and status epilepticus: When using long-acting AEDs to complement benzodiazepines, blood level monitoring confirms that an adequate dosage was given and, if not, a further bolus can be administered with further monitoring. This is particularly useful when using rectal administration of AEDs. (iii) Polypharmacy: Polypharmacy provokes drug interactions in which case AED monitoring helps in differentiating adequate dosing, offending AED with toxicity and free level measuring benefits when total levels are unhelpful. (iv) Generic substitution: Generic AEDs can fluctuate considerably from a parent compound, and even a parent compound, sourced from an alternative supplier, may have altered bioavailability for which blood level monitoring is very useful. While therapeutic blood level monitoring is not a substitute for good clinical judgment, it offers a valuable adjunct to patient care. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. CURRENT USE AND FUTURE NEEDS OF BIODOSIMETRY IN STUDIES OF LONG-TERM HEALTH RISK FOLLOWING RADIATION EXPOSURE

    PubMed Central

    Simon, Steven L.; Bouville, André; Kleinerman, Ruth

    2009-01-01

    Biodosimetry measurements can potentially be an important and integral part of the dosimetric methods used in long-term studies of health risk following radiation exposure. Such studies rely on accurate estimation of doses to the whole body or to specific organs of individuals in order to derive reliable estimates of cancer risk. However, dose estimates based on analytical dose reconstruction (i.e., models) or personnel monitoring measurements, e.g., film-badges, can have substantial uncertainty. Biodosimetry can potentially reduce uncertainty in health risk studies by corroboration of model-based dose estimates or by using them to assess bias in dose models. While biodosimetry has begun to play a more significant role in long-term health risk studies, its use is still generally limited in that context due to one or more factors including, inadequate limits of detection, large inter-individual variability of the signal measured, high per-sample cost, and invasiveness. Presently, the most suitable biodosimetry methods for epidemiologic studies are chromosome aberration frequencies from fluorescence in situ hybridization (FISH) of peripheral blood lymphocytes and electron paramagnetic resonance (EPR) measurements made on tooth enamel. Both types of measurements, however, are usually invasive and require difficult to obtain biological samples. Moreover, doses derived from these methods are not always directly relevant to the tissues of interest. To increase the value of biodosimetry to epidemiologic studies, a number of issues need to be considered including limits of detection, effects of inhomogenous exposure of the body, how to extrapolate from the tissue sampled to the tissues of interest, and how to adjust dosimetry models applied to large populations based on sparse biodosimetry measurements. The requirements of health risk studies suggest a set of characteristics that, if satisfied by new biodosimetry methods, would increase the overall usefulness of biodosimetry to determining radiation health risks. PMID:20065672

  16. [Mechanisms of action, pharmacology and interactions of dolutegravir].

    PubMed

    Ribera, Esteban; Podzamczer, Daniel

    2015-03-01

    Dolutegravir is a second-generation integrase strand transfer inhibitor (INSTI), whose potential and binding half-life in the integrase are far superior to those of raltegravir and elvitegravir, conferring it with unique characteristics in terms of its genetic barrier to resistance and activity against viruses with one or more mutations in the integrase. The pharmacokinetic properties of dolutegravir allow once-daily dosing (50 mg), with or without food, maintaining concentrations far above those effective against wild-type viruses. If integrase resistance mutations are present, the recommended dosing regimen is 50 mg/12 h. The distribution of dolutegravir in cerebrospinal fluid is good and effective concentrations are also reached in the male and female genital tracts. Dolutegravir is metabolized by UGT1A1 and, to a lesser extent, by CYP3A4, without being an inducer or inhibitor of the usual metabolic systems. It has a very low potential for drug interactions and can be administered in routine doses with most drugs. Dose adjustment is not required, even in patients with renal insufficiency or mild or moderate liver failure. Increasing the dose of dolutegravir (50 mg/12 h) is only recommended when administered with efavirenz, nevirapine, fosamprenavir/r, tipranavir/r, rifampicin, carbamazepine, phenytoin and phenobarbital. Coadministration of dolutegravir with etravirine is not recommended without a protease inhibitor or with Hypericum perforatum. Dolutegravir should be administered 2 h before or 6 h after antacids or products with polyvalent cations. Dolutegravir can reduce renal tubule secretion of substances excreted via OCT2, with a slight initial increase in creatinine, with no risk of renal toxicity. The drug can also increase metformin concentrations and consequently monitoring is recommended in case dose adjustment is required. In summary, dolutegravir has excellent pharmacokinetic and drug interaction profiles. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  17. Applying DOE's Graded Approach for assessing radiation impacts to non-human biota at the INL.

    PubMed

    Morris, Randall C

    2006-01-01

    In July 2002, The US Department of Energy (DOE) released a new technical standard entitled A Graded Approach for Evaluating Radiation Doses to Aquatic and Terrestrial Biota. DOE facilities are annually required to demonstrate that routine radioactive releases from their sites are protective of non-human receptors and sites are encouraged to use the Graded Approach for this purpose. Use of the Graded Approach requires completion of several preliminary steps, to evaluate the degree to which the site environmental monitoring program is appropriate for evaluating impacts to non-human biota. We completed these necessary activities at the Idaho National Laboratory (INL) using the following four tasks: (1) develop conceptual models and evaluate exposure pathways; (2) define INL evaluation areas; (3) evaluate sampling locations and media; (4) evaluate data gaps. All of the information developed in the four steps was incorporated, data sources were identified, departures from the Graded Approach were justified, and a step-by-step procedure for biota dose assessment at the INL was specified. Finally, we completed a site-wide biota dose assessment using the 2002 environmental surveillance data and an offsite assessment using soil and surface water data collected since 1996. These assessments demonstrated the environmental concentrations of radionuclides measured on and near the INL do not present significant risks to populations of non-human biota.

  18. Dexmedetomidine use in the ED for control of methamphetamine-induced agitation.

    PubMed

    Lam, Rex Pui Kin; Yip, Wai Lam; Wan, Chi Keung; Tsui, Matthew Sik Hon

    2017-04-01

    Chemical restraint is often required to control agitation induced by methamphetamine. Dexmedetomidine is an α-2 adrenergic receptor agonist with sedative, analgesic, and sympatholytic properties. Its use in the emergency department (ED) to control methamphetamine-induced agitation has not been reported. To report two cases of methamphetamine-induced agitation successfully sedated with dexmedetomidine in the ED. The first case was a 42-year-old man with unstable emotion and violent behaviours after smoking methamphetamine. His agitation did not respond to a large cumulative dose of benzodiazepines (10mg of diazepam and 332mg of midazolam) administered over 48h and sedation was achieved with dexmedetomidine. The second case was a 38-year-old methamphetamine user with unstable emotion and recurrent episodes of agitation despite repeated doses of benzodiazepines, whose agitation was controlled with dexmedetomidine infusion. In both cases, dexmedetomidine apparently reduced the dose of benzodiazepines needed to achieve adequate sedation. Transient falls in blood pressure and slowing of the heart rate were noted, which resolved either spontaneously or after reducing the infusion rate without requiring drug treatment. Dexmedetomidine can be considered as an adjunct for chemical restraint when standard treatment fails to control the agitation induced by methamphetamine, but patient's hemodynamic state should be monitored closely during administration. Its efficacy and safety in the ED warrant further evaluation with prospective controlled trials. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model

    PubMed Central

    Chu, Kuang Hua; Lin, Yu Ting; Hsu, Chia Chun; Chen, Chien Yi; Pan, Lung Kwang

    2012-01-01

    This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5–19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility. PMID:22915780

  20. A retrospective analysis of outcomes of dalteparin use in pediatric patients: a single institution experience.

    PubMed

    Warad, Deepti; Rao, Amulya Nageswara; Mullikin, Trey; Graner, Kevin; Shaughnessy, William J; Pruthi, Rajiv K; Rodriguez, Vilmarie

    2015-08-01

    Dalteparin is a commonly used low molecular weight heparin (LMWH) with extensive safety data in adults. With distinct advantages of once daily dosing and relative safety in renal impairment, it has been used off-label in pediatric practice; however, age-based dosing guidelines, safety and efficacy data in children are evolving. To report our institutional experience with the use of dalteparin in the treatment and prophylaxis of venous thromboembolism (VTE) in pediatric patients. Retrospective chart review of all children (0-18years) that received dalteparin from December 1, 2000 through December 31, 2011. Doses per unit body weight per day (units/kg/day) were calculated for age-based group comparisons. Of 166 patients identified, 116 (70%) received prophylactic doses while 50 (30%) received therapeutic doses of dalteparin. Infants (<1year) required significantly higher weight-based dosing to achieve therapeutic anti-Xa levels compared to children (1-10years) or adolescents (>10-18years) (mean dose units/kg/day; 396.6 versus 236.7 and 178.8 respectively, p<0.0001). Overall response rate, including complete and partial thrombus resolution, was 83%. Bleeding complications were minor and the rates were similar in therapeutic and prophylaxis patients. No significant differences in dosing or bleeding events were noted based on obesity or malignancy. In our experience, dalteparin is effective for prophylaxis and therapy of VTE in pediatric patients. Dosing should be customized in an age-based manner with close monitoring of anti-Xa activity in order to achieve optimal levels, prevent bleeding complications, and to allow full benefit of prevention or therapy of thrombotic complications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, C A; Clarke, S D; Pozzi, S A

    Purpose: To develop an instrument for measuring neutron and photon dose rates from mixed fields with a single device. Methods: Stilbene organic scintillators can be used to detect fast neutrons and photons. Stilbene was used to measure emission from mixed particle sources californium-252 (Cf-252) and plutonium-beryllium (PuBe). Many source detector configurations were used, along with varying amounts of shielding. Collected spectra were analyzed using pulse shape discrimination software, to separate neutron and photon interactions. With a measured light output to energy relationship the pulse height spectrum was converted to energy deposited in the detector. Energy deposited was converted to dosemore » with a variety of standard dose factors, for comparison to current methods. For validation, all measurements and processing was repeated using an EJ-309 liquid scintillator detector. Dose rates were also measured in the same configuration with commercially available dose meters for further validation. Results: Measurements of dose rates will show agreement across all methods. Higher accuracy of pulse shape discrimination at lower energies with stilbene leads to more accurate measurement of neutron and photon deposited dose. In strong fields of mixed particles discrimination can be performed well at a very low energy threshold. This shows accurate dose measurements over a large range of incident particle energy. Conclusion: Stilbene shows promise as a material for dose rate measurements due to its strong ability for separating neutrons and photon pulses and agreement with current methods. A dual particle dose meter would simplify methods which are currently limited to the measurement of only one particle type. Future work will investigate the use of a silicon photomultiplier to reduce the size and required voltage of the assembly, for practical use as a handheld survey meter, room monitor, or phantom installation. Funding From the United States Department of Energy and the National Nuclear Security Administration.« less

  2. Evaluation of the effect of torsemide on warfarin dosage requirements.

    PubMed

    Lai, Sophia; Momper, Jeremiah D; Yam, Felix K

    2017-08-01

    Background According to drug interaction databases, torsemide may potentiate the effects of warfarin. Evidence for this drug-drug interaction, however, is conflicting and the clinical significance is unknown. Objective The aim of this study is to evaluate the impact of torsemide initiation on warfarin dosage requirements. Setting This study was conducted at the Veterans Affairs Healthcare System in San Diego, California. Method A retrospective cohort study was conducted using Veterans Affairs data from patients who were converted from bumetanide to torsemide between March 2014 and July 2014. Patients were also prescribed and taking warfarin during the observation period. Warfarin dosage requirements were evaluated to determine if any changes occurred within the first 3 months of starting torsemide. Main outcome measure The primary outcome was the average weekly warfarin dose before and after torsemide initiation. Results Eighteen patients met study inclusion criteria. The weekly warfarin dose before and after initiation of torsemide was not significantly different (34 ± 15 and 34 ± 13 mg, p > 0.05). Of those eighteen patients, only two experienced elevations in INR that required a decrease in warfarin dosage after torsemide initiation. Between those two patients, dosage reductions ranged from 5.3 to 18%. Conclusion These results indicated that most patients did not require any warfarin dosage adjustments after torsemide was initiated. The potential for interaction, however, still exists. While empiric warfarin dosage adjustments are not recommended when initiating torsemide, increased monitoring is warranted to minimize the risk of adverse effects.

  3. Specification and Verification of Medical Monitoring System Using Petri-nets.

    PubMed

    Majma, Negar; Babamir, Seyed Morteza

    2014-07-01

    To monitor the patient behavior, data are collected from patient's body by a medical monitoring device so as to calculate the output using embedded software. Incorrect calculations may endanger the patient's life if the software fails to meet the patient's requirements. Accordingly, the veracity of the software behavior is a matter of concern in the medicine; moreover, the data collected from the patient's body are fuzzy. Some methods have already dealt with monitoring the medical monitoring devices; however, model based monitoring fuzzy computations of such devices have been addressed less. The present paper aims to present synthesizing a fuzzy Petri-net (FPN) model to verify behavior of a sample medical monitoring device called continuous infusion insulin (INS) because Petri-net (PN) is one of the formal and visual methods to verify the software's behavior. The device is worn by the diabetic patients and then the software calculates the INS dose and makes a decision for injection. The input and output of the infusion INS software are not crisp in the real world; therefore, we present them in fuzzy variables. Afterwards, we use FPN instead of clear PN to model the fuzzy variables. The paper follows three steps to synthesize an FPN to deal with verification of the infusion INS device: (1) Definition of fuzzy variables, (2) definition of fuzzy rules and (3) design of the FPN model to verify the software behavior.

  4. High-dose Versus Low-dose Tranexamic Acid to Reduce Transfusion Requirements in Pediatric Scoliosis Surgery.

    PubMed

    Johnson, Daniel J; Johnson, Christine C; Goobie, Susan M; Nami, Nina; Wetzler, Joshua A; Sponseller, Paul D; Frank, Steven M

    2017-12-01

    Our objective was to quantify blood loss and transfusion requirements for high-dose and low-dose tranexamic acid (TXA) dosing regimens in pediatric patients undergoing spinal fusion for correction of idiopathic scoliosis. Previous investigators have established the efficacy of TXA in pediatric scoliosis surgery; however, the dosing regimens vary widely and the optimal dose has not been established. We retrospectively analyzed electronic medical records for 116 patients who underwent spinal fusion surgery for idiopathic scoliosis by a single surgeon and were treated with TXA. In total, 72 patients received a 10 mg/kg loading dose with a 1 mg/kg/h maintenance dose (low-dose) and 44 patients received 50 mg/kg loading dose with a 5 mg/kg/h maintenance dose (high-dose). Estimated blood loss and transfusion requirements were compared between dosing groups. Patient characteristics were nearly identical between the 2 groups. Compared with the low-dose TXA group, the high-dose TXA group had decreased estimated blood loss (695 vs. 968 mL, P=0.01), and a decrease in both intraoperative (0.3 vs. 0.9 units, P=0.01) and whole hospitalization (0.4 vs. 1.0 units, P=0.04) red blood cell transfusion requirements. The higher-dose TXA was associated with decreased intraoperative (P=0.01), and whole hospital transfusion (P=0.01) requirements, even after risk-adjustment for potential confounding variables. High-dose TXA is more effective than low-dose TXA in reducing blood loss and transfusion requirements in pediatric idiopathic scoliosis patients undergoing surgery. Level-III, retrospective cohort study.

  5. High dose-per-pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical use.

    PubMed

    Jaccard, Maud; Durán, Maria Teresa; Petersson, Kristoffer; Germond, Jean-François; Liger, Philippe; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François; Bailat, Claude

    2018-02-01

    The Oriatron eRT6 is an experimental high dose-per-pulse linear accelerator (linac) which was designed to deliver an electron beam with variable dose-rates, ranging from a few Gy/min up to hundreds of Gy/s. It was built to study the radiobiological effects of high dose-per-pulse/dose-rate electron beam irradiation, in the context of preclinical and cognitive studies. In this work, we report on the commissioning and beam monitoring of the Oriatron eRT6 prototype linac. The beam was characterized in different steps. The output stability was studied by performing repeated measurements over a period of 20 months. The relative output variations caused by changing beam parameters, such as the temporal electron pulse width, the pulse repetition frequency and the pulse amplitude were also analyzed. Finally, depth dose curves and field sizes were measured for two different beam settings, resulting in one beam with a conventional radiotherapy dose-rate and one with a much higher dose-rate. Measurements were performed with Gafchromic EBT3 films and with a PTW Advanced Markus ionization chamber. In addition, we developed a beam current monitoring system based on the signals from an induction torus positioned at the beam exit of the waveguide and from a graphite beam collimator. The stability of the output over repeated measurements was found to be good, with a standard deviation smaller than 1%. However, non-negligible day-to-day variations of the beam output were observed. Those output variations showed different trends depending on the dose-rate. The analysis of the relative output variation as a function of various beam parameters showed that in a given configuration, the dose-rate could be reliably varied over three orders of magnitude. Interdependence effects on the output variation between the parameters were also observed. The beam energy and field size were found to be slightly dose-rate-dependent and suitable mainly for small animal irradiation. The beam monitoring system was able to measure in a reproducible way the total charge of electrons that exit the machine, as long as the electron pulse amplitude remains above a given threshold. Furthermore, we were able to relate the charge measured with the monitoring system to the absorbed dose in a solid water phantom. The Oriatron eRT6 was successfully commissioned for preclinical use and is currently in full operation, with studies being performed on the radiobiological effects of high dose-per-pulse irradiation. © 2017 American Association of Physicists in Medicine.

  6. Activation of QA devices and phantom materials under clinical scanning proton beams—a gamma spectrometry study

    NASA Astrophysics Data System (ADS)

    Hanušová, Tereza; Johnová, Kamila; Navrátil, Matěj; Valenta, Jiří; Müller, Lutz

    2018-06-01

    Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.

  7. Activation of QA devices and phantom materials under clinical scanning proton beams-a gamma spectrometry study.

    PubMed

    Hanušová, Tereza; Johnová, Kamila; Navrátil, Matěj; Valenta, Jiří; Müller, Lutz

    2018-06-07

    Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.

  8. Pharmacokinetics and therapeutic drug monitoring of psychotropic drugs in pediatrics.

    PubMed

    Pichini, Simona; Papaseit, Esther; Joya, Xavier; Vall, Oriol; Farré, Magí; Garcia-Algar, Oscar; de laTorre, Rafael

    2009-06-01

    Therapeutic drug monitoring (TDM) in pediatrics (0-14 years) is especially important because the absorption, distribution, metabolism, and excretion of drugs and drug pharmacokinetic profiles can be different from that of the adult population. In this context, several parameters like half-life of drug elimination from the body (t(1/2)), peak plasma concentration (Cmax), area under the curve, clearance (CL), Tmax, and dose/concentration relationship in children may differ from adults. Hence, the knowledge of pharmacokinetic parameters and therapeutic and toxic ranges of drug concentrations may help the clinicians to optimize drug treatment regimens in the pediatric population. TDM of psychotropic drugs requires particular attention for the pharmacological and clinical consequences of nonadequate dose use, lack in the compliance, and overdoses with possible toxic effects. Psychoactive drugs such as benzodiazepines, antiepileptic drugs, tricyclic antidepressants, selective serotonin reuptake inhibitors, antipsychotic drugs, psychostimulants (attention-deficit hyperactivity disorder drugs), opioid analgesics, and antimigraine drugs are a heterogeneous group. These drugs are subject to interindividual variability, and therefore, the usefulness of TDM for these drugs has to be assessed individually. Because of the occurrence of comorbid pathologies, including psychiatric disorders, the use of combined pharmacotherapy is not uncommon. As a consequence, these patients may be at risk from a number of potential drug-drug interactions. The implementation of TDM in pediatric population is more difficult than in adults because some sampling procedures are invasive and cause discomfort in children, and additionally, they require the cooperation of the patient. Several examples will be provided where the use of alternative matrices, such as saliva, is proposed to minimize inconvenience and patient discomfort.

  9. Temporal variation of dose rate distribution around the Fukushima Daiichi nuclear power station using unmanned helicopter.

    PubMed

    Sanada, Yukihisa; Orita, Tadashi; Torii, Tatsuo

    2016-12-01

    Aerial radiological survey using an unmanned aerial vehicle (UAV) was applied to measurement surface contamination around the Fukushima Daiichi nuclear power station (FDNPS). An unmanned helicopter monitoring system (UHMS) was developed to survey the environmental effect of radioactive cesium scattered as a result of the FDNPS accident. The UHMS was used to monitor the area surrounding the FDNPS six times from 2012 to 2015. Quantitative changes in the radioactivity distribution trend were revealed from the results of these monitoring runs. With this information, we found that the actual reduction of dose rate was faster than the one calculated with radiocesium physical half-life. It is indicated that the attenuation effect of radiation by radiocesium penetration in soil is dominant as for reason of reduction of dose rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. SU-E-T-108: Development of a Novel Clinical Neutron Dose Monitor for Proton Therapy Based On Twin TLD500 Chips in a Small PE Moderator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hentschel, R; Mukherjee, B

    2014-06-01

    Purpose: In proton therapy, it could be desirable to measure out-of-field fast neutron doses at critical locations near and outside the patient body. Methods: The working principle of a novel clinical neutron dose monitor is verified by MCNPX simulation. The device is based on a small PE moderator of just 5.5cm side length for easy handling covered with a thermal neutron suppression layer. In the simulation, a polystyrene phantom is bombarded with a standard proton beam. The secondary thermal neutron flux produced inside the moderator by the impinging fast neutrons from the treatment volume is estimated by pairs of α-Al2O3:Cmore » (TLD500) chips which are evaluated offline after the treatment either by TL or OSL methods. The first chip is wrapped with 0.5mm natural Gadolinium foil converting the thermal neutrons to gammas via (n,γ) reaction. The second chip is wrapped with a dummy material. The chip centers have a distance of 2cm from each other. Results: The simulation shows that the difference of gamma doses in the TLD500 chips is correlated to the mean fast neutron dose delivered to the moderator material. Different outer shielding materials have been studied. 0.5mm Cadmium shielding is preferred for cost reasons and convenience. Replacement of PE moderator material by other materials like lead or iron at any place is unfavorable. The spatial orientation of the moderator cube is uncritical. Using variance reduction techniques like splitting/Russian roulette, the TLD500 gamma dose simulation give positive differences up to distances of 0.5m from the treatment volume. Conclusion: Applicability and basic layout of a novel clinical neutron dose monitor are demonstrated. The monitor measures PE neutron doses at locations outside the patient body up to distances of 0.5m from the treatment volume. Tissue neutron doses may be calculated using neutron kerma factors.« less

  11. Anticoagulant management in the cardiovascular setting.

    PubMed

    Verheugt, Freek W A

    2012-02-01

    Vitamin K antagonists have been used as oral anticoagulants (OACs) for over five decades, yet their use in real-world practice is problematic primarily because of their narrow therapeutic window, exacerbated by extensive food and drug interactions, necessitating regular coagulation monitoring and dose adjustment. Around half of patients receiving warfarin are within the therapeutic range, exposing them to the dangers of under-anticoagulation (i.e. thrombosis formation) or over-anticoagulation (i.e. bleeding). A new generation of OACs with improved pharmacology promises to revolutionize antithrombotic management. Rivaroxaban, apixaban (both oral direct Factor Xa inhibitors) and dabigatran (a direct thrombin inhibitor) all exhibit predictable anticoagulant responses and few drug-drug interactions and do not require routine coagulation monitoring. © 2011 The Author Fundamental and Clinical Pharmacology © 2011 Société Française de Pharmacologie et de Thérapeutique.

  12. Whole-body to tissue concentration ratios for use in biota dose assessments for animals.

    PubMed

    Yankovich, Tamara L; Beresford, Nicholas A; Wood, Michael D; Aono, Tasuo; Andersson, Pål; Barnett, Catherine L; Bennett, Pamela; Brown, Justin E; Fesenko, Sergey; Fesenko, J; Hosseini, Ali; Howard, Brenda J; Johansen, Mathew P; Phaneuf, Marcel M; Tagami, Keiko; Takata, Hyoe; Twining, John R; Uchida, Shigeo

    2010-11-01

    Environmental monitoring programs often measure contaminant concentrations in animal tissues consumed by humans (e.g., muscle). By comparison, demonstration of the protection of biota from the potential effects of radionuclides involves a comparison of whole-body doses to radiological dose benchmarks. Consequently, methods for deriving whole-body concentration ratios based on tissue-specific data are required to make best use of the available information. This paper provides a series of look-up tables with whole-body:tissue-specific concentration ratios for non-human biota. Focus was placed on relatively broad animal categories (including molluscs, crustaceans, freshwater fishes, marine fishes, amphibians, reptiles, birds and mammals) and commonly measured tissues (specifically, bone, muscle, liver and kidney). Depending upon organism, whole-body to tissue concentration ratios were derived for between 12 and 47 elements. The whole-body to tissue concentration ratios can be used to estimate whole-body concentrations from tissue-specific measurements. However, we recommend that any given whole-body to tissue concentration ratio should not be used if the value falls between 0.75 and 1.5. Instead, a value of one should be assumed.

  13. Phenytoin kinetics during pregnancy and the puerperium.

    PubMed

    Knott, C; Williams, C P; Reynolds, F

    1986-10-01

    During pregnancy changes in maternal physiology and plasma composition may alter drug binding and dose requirements. We have measured plasma unbound and total phenytoin, and saliva concentrations at intervals in 11 pregnant epileptics. Plasma albumin concentrations were also measured in pregnant and non-pregnant women. Saliva phenytoin correlated closely with the plasma unbound concentrations (r = 0.98). The saliva:plasma (S:P) ratio, reflecting the free fraction, was variable during pregnancy but tended to increase to maximal values at delivery and return to non-pregnant values within 2-8 weeks thereafter. Plasma albumin concentrations correlated poorly with phenytoin binding. Binding in umbilical cord plasma appeared higher than that in maternal plasma and total fetal concentrations correlated closely with maternal plasma concentrations at delivery. No ill effects of phenytoin were detected in the newborn infant. During the third trimester phenytoin dose increments were necessary to maintain therapeutic concentrations. After delivery maternal saliva phenytoin concentrations rose, and dose reductions were necessary to avoid clinical symptoms of toxicity. It is therefore appropriate to monitor saliva phenytoin concentrations regularly both during pregnancy and the puerperium.

  14. Compliance and patching and atropine amblyopia treatments.

    PubMed

    Wang, Jingyun

    2015-09-01

    In the past 20 years, there has been a great advancement in knowledge pertaining to compliance with amblyopia treatments. The occlusion dose monitor introduced quantitative monitoring methods in patching, which sparked our initial understanding of the dose-response relationship for patching amblyopia treatment. This review focuses on current compliance knowledge and the impact it has on patching and atropine amblyopia treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Treatment of Addison's disease during pregnancy.

    PubMed

    Oliveira, Diana; Lages, Adriana; Paiva, Sandra; Carrilho, Francisco

    2018-01-01

    Addison's disease, or primary adrenocortical insufficiency, is a long-term, potentially severe, rare endocrine disorder. In pregnancy, it is even rarer. We report the case of a 30-year-old pregnant patient with Addison's disease, referred to Obstetrics-Endocrinology specialty consult at 14 weeks gestation. She had been to the emergency department of her local hospital various times during the first trimester presenting with a clinical scenario suggestive of glucocorticoid under-replacement (nausea, persistent vomiting and hypotension), but this was interpreted as normal pregnancy symptoms. Hydrocortisone dose was adjusted, and the patient maintained regular follow-up. No complications were reported for the remainder of gestation and delivery. Pregnant patients with Addison's disease should be monitored during gestation and in the peripartum period by multidisciplinary teams. Adjustments in glucocorticoid and mineralocorticoid replacement therapy are often necessary, and monitoring should be based mainly on clinical findings, which becomes increasingly difficult during pregnancy. Patient education and specialized monitoring are key to avoiding complications from under- or over-replacement therapy in this period. An increase in glucocorticoid replacement dose is expected to be necessary during pregnancy in a woman with Addison's disease.Patient education regarding steroid cover and symptoms of acute adrenal crisis are fundamental.Monitoring in this period is challenging and remains mainly clinical.The increase in hydrocortisone dose often obviates the need to increase fludrocortisone dose.

  16. Wide-range radiation dose monitor

    DOEpatents

    Kopp, Manfred K.

    1986-01-01

    A radiation dose-rate monitor is provided which operates in a conventional linear mode for radiation in the 0 to 0.5 R/h range and utilizes a nonlinear mode of operation for sensing radiation from 0.5 R/h to over 500 R/h. The nonlinear mode is achieved by a feedback circuit which adjusts the high voltage bias of the proportional counter, and hence its gas gain, in accordance with the amount of radiation being monitored. This allows compression of readout onto a single scale over the range of 0 to greater than 500 R/h without scale switching operations.

  17. Wide-range radiation dose monitor

    DOEpatents

    Kopp, M.K.

    1984-09-20

    A radiation dose-rate monitor is provided which operates in a conventional linear mode for radiation in the 0 to 0.5 R/h range and utilizes a nonlinear mode of operation for sensing radiation from 0.5 R/h to over 500 R/h. The nonlinear mode is achieved by a feedback circuit which adjusts the high voltage bias of the proportional counter, and hence its gas gain, in accordance with the amount of radiation being monitored. This allows compression of readout onto a single scale over the range of 0 to greater than 500 R/h without scale switching operations.

  18. The development of remote wireless radiation dose monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jin-woo; Chonbuk National University, Jeonjoo-Si; Jeong, Kyu-hwan

    Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Somemore » of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)« less

  19. Extravasation of a therapeutic dose of 131I-metaiodobenzylguanidine: prevention, dosimetry, and mitigation.

    PubMed

    Bonta, Dacian V; Halkar, Raghuveer K; Alazraki, Naomi

    2011-09-01

    After the extravasation of a therapeutic dose of (131)I-metaiodobenzylguanidine that produced a radiation burn to a patient's forearm, we instituted a catheter placement verification protocol. Before therapy infusion, proper placement is verified by administering 37 MBq of (99m)Tc-pertechnetate through the catheter, and monitoring activity at the administration site and on the contralateral extremity. A dosimetric model describing both high-rate and low-rate dose components was developed and predicted that the basal epidermal layer received a radiation dose consistent with the observed moist desquamation radiation skin toxicity. No extravasation incidents have occurred since the verification procedure was instituted. To protect against radiation injury from extravasation of therapeutic radionuclides, test administration of a small (99m)Tc dose with probe monitoring of comparable sites in both upper extremities appears to be an effective preventive measure.

  20. Microdosemeter instrument (MIDN) for assessing risk in space.

    PubMed

    Pisacane, V L; Dolecek, Q E; Malak, H; Cucinotta, F A; Zaider, M; Rosenfeld, A B; Rusek, A; Sivertz, M; Dicello, J F

    2011-02-01

    Radiation in space generally produces higher dose rates than that on the Earth's surface, and contributions from primary galactic and solar events increase with altitude within the magnetosphere. Presently, no personnel monitor is available to astronauts for real-time monitoring of dose, radiation quality and regulatory risk. This group is developing a prototypic instrument for use in an unknown, time-varying radiation field. This microdosemeter-dosemeter nucleon instrument is for use in a spacesuit, spacecraft, remote rover and other applications. It provides absorbed dose, dose rate and dose equivalent in real time so that action can be taken to reduce exposure. Such a system has applications in health physics, anti-terrorism and radiation-hardening of electronics as well. The space system is described and results of ground-based studies are presented and compared with predictions of transport codes. An early prototype in 2007 was successfully launched, the only solid-state microdosemeter to have flown in space.

  1. SU-E-I-10: Automatic Monitoring of Accumulated Dose Indices From DICOM RDSR to Improve Radiation Safety in X-Ray Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omar, A; Bujila, R; Nowik, P

    2014-06-01

    Purpose: To investigate the potential benefits of automatic monitoring of accumulated patient and staff dose indicators, i.e., CAK and KAP, from DICOM Radiation Dose Structured Reports (RDSR) in x-ray angiography (XA). Methods: Recently RDSR has enabled the convenient aggregation of dose indices and technique parameters for XA procedures. The information contained in RDSR objects for three XA systems, dedicated to different types of clinical procedures, has been collected and aggregated in a database for over one year using a system developed with open-source software at the Karolinska University Hospital. Patient weight was complemented to the RDSR data via an interfacemore » with the Hospital Information System (HIS). Results: The linearly approximated trend in KAP over a time period of a year for cerebrovascular, pelvic/peripheral vascular, and cardiovascular procedures showed a decrease of 12%, 20%, and 14%, respectively. The decrease was mainly due to hardware/software upgrades and new low-dose imaging protocols, and partially due to ongoing systematic radiation safety education of the clinical staff. The CAK was in excess of 3 Gy for 15 procedures, and exceeded 5 Gy for 3 procedures. The dose indices have also shown a significant dependence on patient weight for cardiovascular and pelvic/peripheral vascular procedures; a 10 kg shift in mean patient weight can result in a dose index increase of 25%. Conclusion: Automatic monitoring of accumulated dose indices can be utilized to notify the clinical staff and medical physicists when the dose index has exceeded a predetermined action level. This allows for convenient and systematic follow-up of patients in risk of developing deterministic skin injuries. Furthermore, trend analyses of dose indices over time is a valuable resource for the identification of potential positive or negative effects (dose increase/decrease) from changes in hardware, software, and clinical work habits.« less

  2. SU-F-T-474: Evaluation of Dose Perturbation, Temperature and Sensitivity Variation With Accumulated Dose of MOSFET Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganesan, B; Prakasarao, A; Singaravelu, G

    Purpose: The use of mega voltage gamma and x-ray sources with their skin sparring qualities in radiation therapy has been a boon in relieving patient discomfort and allowing high tumor doses to be given with fewer restrictions due to radiation effects in the skin. However, high doses given to deep tumors may require careful consideration of dose distribution in the buildup region in order to avoid irreparable damage to the skin. Methods: To measure the perturbation of MOSFET detector in Co60,6MV and 15MV the detector was placed on the surface of the phantom covered with the brass build up cap.more » To measure the effect of temperature the MOSFET detector was kept on the surface of hot water polythene container and the radiation was delivere. In order to measure the sensitivity variation with accumulated dose Measurements were taken by delivering the dose of 200 cGy to MOSFET until the MOSFET absorbed dose comes to 20,000 cGy Results: the Measurement was performed by positioning the bare MOSFET and MOSFET with brass build up cap on the top surface of the solid water phantom for various field sizes in order to find whether there is any attenuation caused in the dose distribution. The response of MOSFET was monitored for temperature ranging from 42 degree C to 22 degree C. The integrated dose dependence of MOSFET dosimeter sensitivity over different energy is not well characterized. This work investigates the dual-bias MOSFET dosimeter sensitivity response to 6 MV and 15 MV beams. Conclusion: From this study it is observed that unlike diode, bare MOSFET does not perturb the radiation field.. It is observed that the build-up influences the temperature dependency of MOSFET and causes some uncertainty in the readings. In the case of sensitivity variation with accumulated dose MOSFET showed higher sensitivity with dose accumulation for both the energies.« less

  3. Review of proton pump inhibitors for the initial treatment of heartburn: is there a dose ceiling effect?

    PubMed

    Kushner, Pamela R; Peura, David A

    2011-05-01

    Proton pump inhibitors (PPIs) are widely used in clinical practice. However, concerns have been expressed about their long-term use, particularly with regard to bone health, Clostridium difficile infections, and drug interactions with platelet aggregation inhibitors. There has been limited guidance for clinicians concerning appropriate dose selection of PPIs for the initial treatment of heartburn. This review explored whether published clinical trials provide evidence of a ceiling above which higher PPI doses do not provide additional clinical benefit over the lowest approved dose. All articles of randomized, controlled clinical trials in nonerosive gastroesophageal reflux disease (GERD) in which the effects of two or more doses of the same PPI on symptomatic relief of heartburn were quantified as a study endpoint were identified and analyzed through PubMed searches up to the end of September 2010. The majority of trials evaluated provided no evidence that higher PPI doses were superior to the lowest approved dose for the initial treatment of heartburn. There were no clinically relevant findings with respect to dose dependence and safety outcomes in these studies. Efficacy outcomes from the trials suggest there may be a dose ceiling effect and highlight the need for further research on the use of the lowest effective PPI doses as an appropriate strategy in the initial treatment of uncomplicated heartburn. Observational studies and some meta-analyses have suggested that long-term PPI pharmacotherapy might be associated with safety concerns, which necessitate the periodic evaluation of therapeutic benefit in terms of symptom resolution and regimen tolerability. However, evidence to date suggests that use of the lowest effective dose for the indication is not associated with significant adverse events, particularly in the short term. Clinical practice suggests that patients requiring long-term treatment should be maintained on the lowest dose necessary to control symptoms, and monitored for potentially confounding factors that may lead to safety concerns.

  4. Somatic health effects of Chernobyl: 30 years on.

    PubMed

    Hatch, Maureen; Cardis, Elisabeth

    2017-12-01

    2016 marked the 30th anniversary of the Chernobyl Nuclear Power Plant accident. We and others wrote reviews for the 25th anniversary. Since then, additional papers have appeared and it seems timely to highlight lessons learned. To present, not a systematic review, but a commentary drawing attention to notable findings. We include not only recent reports and updates on previous results, but key findings from prior Chernobyl studies. The dose-dependent increase in Papillary Thyroid Cancer (PTC) following childhood I-131 exposure in Ukraine and Belarus has now been shown to persist for decades. Studies of post-Chernobyl PTCs have produced novel information on chromosomal rearrangements and gene fusions, critical to understanding molecular mechanisms. Studies of clean-up workers/liquidators suggest dose-related increases of thyroid cancer and hematological malignancies in adults. They also report increases in cardiovascular and cerebrovascular disease. If confirmed, these would have significant public health and radiation protection implications. The lens opacities following low to moderate doses found earlier are also a concern, particularly among interventional radiologists who may receive substantial lens doses. Finally, there is some, inconsistent, evidence for genetic effects among offspring of exposed persons. Further efforts, including improved dosimetry, collection of information on other risk factors, and continued follow-up/monitoring of established cohorts, could contribute importantly to further understand effects of low doses and dose-rates of radiation, particularly in young people, and ensure that appropriate public health and radiation protection systems are in place. This will require multinational collaborations and long-term funding.

  5. Effects of Age, Sex, and Race on the Safety and Pharmacokinetics of Single and Multiple Doses of Azilsartan Medoxomil in Healthy Subjects.

    PubMed

    Harrell, Robert E; Karim, Aziz; Zhang, Wencan; Dudkowski, Caroline

    2016-05-01

    Azilsartan medoxomil (AZL-M) is an angiotensin II receptor blocker approved to treat hypertension. After oral dosing, AZL-M is quickly hydrolyzed to azilsartan (AZL). The aims of this study were to assess the effects of age, sex, and race on the pharmacokinetics of AZL-M in healthy subjects, as well as safety and tolerability. Sixty-one healthy adults were enrolled in this phase I, single-blind, randomized placebo-controlled study (placebo control was for assessment of safety/tolerability only). Subjects were stratified by age (18-45 vs. 65-85 years), sex, and race (black vs. white) and given oral AZL-M 60 mg (3 × 20 mg capsules) or placebo as a single dose (Day 1) and consecutive daily doses (Days 4-8) (6:2 ratio for AZL-M:placebo per group). Pharmacokinetics were evaluated (AZL-M patients only) on Days 1-3 and 8-9 and safety/tolerability was monitored. Age, sex, and race had no clinically meaningful effect on AZL exposures after single or multiple dosing. Pharmacokinetic parameters remained similar between Days 1 and 8 for each age, sex, and race subgroup. The frequency of adverse events was similar for AZL-M (32%) and placebo (29%). No discontinuations or serious adverse events occurred. Based on these pharmacokinetic and safety/tolerability findings, no AZL-M dose adjustments are required based on age, sex, or race (black/white).

  6. Oak Ridge Reservation: Annual Site Environmental Report for 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rochelle, James; Rogers, Ben; Roche, Paula R.

    The Oak Ridge Reservation Annual Site Environmental Report is prepared annually and presents summary environmental data to (1) characterize environmental performance, (2) summarize environmental occurrences reported during the year, (3) confirm compliance with environmental standards and requirements, and (4) highlight significant program activities. The report fulfills the requirement contained in DOE Order 231.1A, Environment, Safety and Health Reporting (DOE 2004) that an integrated annual site environmental report be prepared. The results summarized in this report are based on data collected prior to and through 2015. This report is not intended to nor does it present the results of all environmentalmore » monitoring associated with the ORR. Data collected for other site and regulatory purposes, such as environmental restoration/remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws and are referenced herein as appropriate. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the points of release to the environment; these measurements allow the quantification and official reporting of contaminant levels, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of direct measurements and collection and analysis of samples taken from the site and its environs exclusive of effluents; these activities provide information on contaminant concentrations in air, water, groundwater, soil, foods, biota, and other media. Environmental surveillance data support determinations regarding environmental compliance and, when combined with data from effluent monitoring, support chemical and radiation dose and exposure assessments of the potential effects of ORR operations, if any, on the local environment.« less

  7. Iatrogenic hypervitaminosis D as an unusual cause of persistent vomiting: a case report.

    PubMed

    Bansal, Rinkesh Kumar; Tyagi, Pankaj; Sharma, Praveen; Singla, Vikas; Arora, Veronica; Bansal, Naresh; Kumar, Ashish; Arora, Anil

    2014-02-26

    Vitamin D is increasingly recognized to have several beneficial effects. Vitamin D deficiency is widely prevalent. Physicians often treat patients with high doses of vitamin D for various ailments without any monitoring for adverse effects and the prescribed doses often far exceed requirements resulting in toxicity. We present here a classic case of iatrogenic hypervitaminosis D, which presented with persistent vomiting and acute renal failure. Here we present a case of a 45-year-old Asian Indian woman who presented to us with persistent vomiting the cause of which was iatrogenic hypervitaminosis D. She was treated with intravenous fluid, diuretics and calcitonin and had clinical improvement. We suggest that in any patient presenting with persistent vomiting and hypercalcemia, particularly in the presence of normal parathyroid hormone, a diagnosis of overdose of vitamin D should be suspected. Its treatment not only alleviates symptoms but also prevents ongoing acute kidney injury.

  8. Radiation exposure control from the application of nuclear gauges in the mining industry in Ghana.

    PubMed

    Faanu, A; Darko, E O; Awudu, A R; Schandorf, C; Emi-Reynolds, G; Yeboah, J; Glover, E T; Kattah, V K

    2010-05-01

    The use of nuclear gauges for process control and elemental analysis in the mining industry in Ghana, West Africa, is wide spread and on the increase in recent times. The Ghana Radiation Protection Board regulates nuclear gauges through a system of notification and authorization by registration or licensing, inspection, and enforcement. Safety assessments for authorization and enforcement have been established to ensure the safety and security of radiation sources as well as protection of workers and the general public. Appropriate training of mine staff is part of the efforts to develop the necessary awareness about the safety and security of radiation sources. The knowledge and skills acquired will ensure the required protection and safety at the workplaces. Doses received by workers monitored over a period between 1998 and 2007 are well below the annual dose limit of 20 mSv recommended by the International Commission on Radiological Protection.

  9. Effect of ketoconazole on cyclosporine dose in healthy dogs.

    PubMed

    Dahlinger, J; Gregory, C; Bea, J

    1998-01-01

    To determine the degree to which the dose of oral cyclosporine (CyA), in healthy dogs, can be decreased by concurrent oral administration of ketoconazole. Dogs in this study were observed for physical or biochemical side effects that might have been caused by the administration of CyA and ketoconazole. Prospective research study. Five healthy, intact female Beagle dogs. CyA was administered orally twice daily to achieve stable whole blood trough levels of 400 to 600 ng/mL. Ketoconazole was added at a low therapeutic dose (average dose: 13.6 mg/kg/d) then at a subtherapeutic dose (average dose: 4.7 mg/kg/d). CyA whole blood trough levels were monitored every 3 to 4 days and maintained at 400 to 600 ng/mL by adjusting CyA doses accordingly. Physical examination, CBC, biochemical profile, and urinalysis were performed at 2-week intervals throughout the study period. The initial mean dose of CyA required to achieve target blood levels was 14.5 mg/ kg/d. With concurrent ketoconazole (low therapeutic dose, average dose: 13.6 mg/kg/d) and CyA administration, the CyA dose declined to 3.4 mg/kg/day (range: 1.2 to 5.2 mg/kg/d), representing a 75% reduction in CyA dose and monetary savings of 57.8%. At a subtherapeutic dose of ketoconazole (average dose: 4.7 mg/kg/d), combination therapy resulted in a CyA dose of 10.1 mg/kg/day (4.9 to 10.6 mg/kg/d), representing a 38% reduction in CyA dose and monetary savings of 23.8%. Weight loss and transient hypoalbuminemia of unknown clinical significance were observed. Other physical and biochemical evaluations were unremarkable over the 12-week study period. The oral administration of ketoconazole can be used to reduce substantially the oral CyA dose needed to maintain selected blood levels in healthy dogs. The oral administration of ketoconazole can result in substantial cost savings to owners of dogs receiving CyA after renal allograft transplantation or for the treatment of autoimmune disease.

  10. An online proton beam monitor for cancer therapy based on ionization chambers with micro pattern readout

    NASA Astrophysics Data System (ADS)

    Basile, E.; Carloni, A.; Castelluccio, D. M.; Cisbani, E.; Colilli, S.; De Angelis, G.; Fratoni, R.; Frullani, S.; Giuliani, F.; Gricia, M.; Lucentini, M.; Santavenere, F.; Vacca, G.

    2012-03-01

    A unique compact LINAC accelerator for proton therapy is under development in Italy within the TOP-IMPLART project. The proton beam will reach the kinetic energy of 230 MeV, it will have a widely variable current intensity (0.1-10 μA, with average up to 3.5 nA) associated with a high pulse repetition frequency (1-3.5 μs long pulses at 10-100 Hz). The TOP-IMPLART system will provide a fully active 3+1D dose delivery, that is longitudinal (energy modulation), transverse active spot scanning, and current intensity modulation. These accelerator features will permit a highly conformational dose distribution, which therefore requires an effective, online, beam monitor system with wide dynamic range, good sensitivity, adequate spatial resolution and rapid response. In order to fulfill these requisites a new device is under development for the monitoring of the beam intensity profile, its centroid and direction; it is based on transmission, segmented, ionization chambers with typical active area of 100 × 100 mm2. Micro pattern x/y pad like design has been used for the readout plane in order to maximize the field uniformity, reduce the chamber thickness and obtain both beam coordinates on a single chamber. The chamber prototype operates in ionization region to minimize saturation and discharge effects. Simulations (based on FLUKA) have been carried on to study the perturbation of the chamber on the beam parameters and the effects on the delivered dose (on a water phantom). The charge collected in each channel is integrated by dedicated auto-ranging readout electronics: an original scheme has been developed in order to have an input dynamic range greater than 104 with sensitivity better than 3%. This is achieved by a dynamical adjustment of the integrating capacitance to the signal intensity.

  11. Changes in ambient dose equivalent rates around roads at Kawamata town after the Fukushima accident.

    PubMed

    Kinase, Sakae; Sato, Satoshi; Sakamoto, Ryuichi; Yamamoto, Hideaki; Saito, Kimiaki

    2015-11-01

    Changes in ambient dose equivalent rates noted through vehicle-borne surveys have elucidated ecological half-lives of radioactive caesium in the environment. To confirm that the ecological half-lives are appropriate for predicting ambient dose equivalent rates within living areas, it is important to ascertain ambient dose equivalent rates on/around roads. In this study, radiation monitoring on/around roads at Kawamata town, located about 37 km northwest of the Fukushima Daiichi Nuclear Power Plant, was performed using monitoring vehicles and survey meters. It was found that the ambient dose equivalent rates around roads were higher than those on roads as of October 2012. And withal the ecological half-lives on roads were essentially consistent with those around roads. With dose predictions using ecological half-lives on roads, it is necessary to make corrections to ambient dose equivalent rates through the vehicle-borne surveys against those within living areas. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. PDT dose dosimetry for Photofrin-mediated pleural photodynamic therapy (pPDT)

    NASA Astrophysics Data System (ADS)

    Ong, Yi Hong; Kim, Michele M.; Finlay, Jarod C.; Dimofte, Andreea; Singhal, Sunil; Glatstein, Eli; Cengel, Keith A.; Zhu, Timothy C.

    2018-01-01

    Photosensitizer fluorescence excited by photodynamic therapy (PDT) treatment light can be used to monitor the in vivo concentration of the photosensitizer and its photobleaching. The temporal integral of the product of in vivo photosensitizer concentration and light fluence is called PDT dose, which is an important dosimetry quantity for PDT. However, the detected photosensitizer fluorescence may be distorted by variations in the absorption and scattering of both excitation and fluorescence light in tissue. Therefore, correction of the measured fluorescence for distortion due to variable optical properties is required for absolute quantification of photosensitizer concentration. In this study, we have developed a four-channel PDT dose dosimetry system to simultaneously acquire light dosimetry and photosensitizer fluorescence data. We measured PDT dose at four sites in the pleural cavity during pleural PDT. We have determined an empirical optical property correction function using Monte Carlo simulations of fluorescence for a range of physiologically relevant tissue optical properties. Parameters of the optical property correction function for Photofrin fluorescence were determined experimentally using tissue-simulating phantoms. In vivo measurements of photosensitizer fluorescence showed negligible photobleaching of Photofrin during the PDT treatment, but large intra- and inter-patient heterogeneities of in vivo Photofrin concentration are observed. PDT doses delivered to 22 sites in the pleural cavity of 8 patients were different by 2.9 times intra-patient and 8.3 times inter-patient.

  13. Individualized texting for adherence building (iTAB): improving antiretroviral dose timing among HIV-infected persons with co-occurring bipolar disorder.

    PubMed

    Moore, David J; Poquette, Amelia; Casaletto, Kaitlin B; Gouaux, Ben; Montoya, Jessica L; Posada, Carolina; Rooney, Alexandra S; Badiee, Jayraan; Deutsch, Reena; Letendre, Scott L; Depp, Colin A; Grant, Igor; Atkinson, J Hampton

    2015-03-01

    HIV+ persons with co-occurring bipolar disorder (HIV+/BD+) have elevated rates of medication nonadherence. We conducted a 30-day randomized controlled trial of a two-way, text messaging system, iTAB (n = 25), compared to an active comparison (CTRL) (n = 25) to improve antiretroviral (ARV) and psychotropic (PSY) adherence and dose timing. Both groups received medication adherence psychoeducation and daily texts assessing mood. The iTAB group additionally received personalized medication reminder texts. Participants responded to over 90 % of the mood and adherence text messages. Mean adherence, as assessed via electronic monitoring caps, was high and comparable between groups for both ARV (iTAB 86.2 % vs. CTRL 84.8 %; p = 0.95, Cliff's d = 0.01) and PSY (iTAB 78.9 % vs. CTRL 77.3 %; p = 0.43, Cliff's d = -0.13) medications. However, iTAB participants took ARVs significantly closer to their intended dosing time than CTRL participants (iTAB: 27.8 vs. CTRL: 77.0 min from target time; p = 0.02, Cliff's d = 0.37). There was no group difference on PSY dose timing. Text messaging interventions may represent a low-burden approach to improving timeliness of medication-taking behaviors among difficult-to-treat populations. The benefits of improved dose timing for long-term medication adherence require additional investigation.

  14. A critical review on a globally-licensed, live, orally-administrable, monovalent human rotavirus vaccine: Rotarix.

    PubMed

    Nakagomi, Toyoko; Nakagomi, Osamu

    2009-08-01

    Rotavirus is the major cause of severe gastroenteritis in children worldwide, and two, live, orally-administrable vaccines are licensed globally. They are Rotarix, a monovalent, human rotavirus-based vaccine (GlaxoSmithKline), and RotaTeq, a pentavalent, bovine-human reassortant vaccine (Merck). The RIX4414 strain, a G1P[8] virus, is contained in the Rotarix vaccine. It grows efficiently in the human intestine, as evidenced by vaccine virus shedding into faeces. Efficient multiplication of RIX4414 in the intestines may play a role in stimulating immune effectors other than neutralizing antibodies that may explain the protective immunity against fully heterotypic G2P[4] strains. The protective efficacy against severe rotavirus gastroenteritis afforded by Rotarix is consistently better against strains that share with RIX4414 both G and P serotypes (i.e., G1P[8]), or only P serotype (i.e., G3P[8], G4P[8] and G9P[8]). The Rotarix vaccine is safe regarding intussusception if its first dose is administered between 6 and 12 weeks of age and the last dose by 24 weeks of age with a minimum interval of 4 weeks between the two doses. The expansion by Advisory Committee on Immunization Practices, USA, of the age limit for the first dose to age <15 weeks, and the last dose by 8 months requires close monitoring.

  15. Individualized Texting for Adherence Building (iTAB): Improving Antiretroviral Dose Timing Among HIV-Infected Persons with Co-occurring Bipolar Disorder

    PubMed Central

    Poquette, Amelia; Casaletto, Kaitlin B.; Gouaux, Ben; Montoya, Jessica L.; Posada, Carolina; Rooney, Alexandra S.; Badiee, Jayraan; Deutsch, Reena; Letendre, Scott L.; Depp, Colin A.; Grant, Igor; Atkinson, J. Hampton

    2015-01-01

    HIV+ persons with co-occurring bipolar disorder (HIV+/BD+) have elevated rates of medication nonadherence. We conducted a 30-day randomized controlled trial of a two-way, text messaging system, iTAB (n = 25), compared to an active comparison (CTRL) (n = 25) to improve antiretroviral (ARV) and psychotropic (PSY) adherence and dose timing. Both groups received medication adherence psychoeducation and daily texts assessing mood. The iTAB group additionally received personalized medication reminder texts. Participants responded to over 90 % of the mood and adherence text messages. Mean adherence, as assessed via electronic monitoring caps, was high and comparable between groups for both ARV (iTAB 86.2 % vs. CTRL 84.8 %; p = 0.95, Cliff’s d = 0.01) and PSY (iTAB 78.9 % vs. CTRL 77.3 %; p = 0.43, Cliff’s d = −0.13) medications. However, iTAB participants took ARVs significantly closer to their intended dosing time than CTRL participants (iTAB: 27.8 vs. CTRL: 77.0 min from target time; p = 0.02, Cliff’s d = 0.37). There was no group difference on PSY dose timing. Text messaging interventions may represent a low-burden approach to improving timeliness of medication-taking behaviors among difficult-to-treat populations. The benefits of improved dose timing for long-term medication adherence require additional investigation. PMID:25504449

  16. Meeting The Joint Commission's Dose Incident Identification and External Benchmarking Requirements Using the ACR's Dose Index Registry.

    PubMed

    Bohl, Michael A; Goswami, Roopa; Strassner, Brett; Stanger, Paula

    2016-08-01

    The purpose of this investigation was to evaluate the potential of using the ACR's Dose Index Registry(®) to meet The Joint Commission's requirements to identify incidents in which the radiation dose index from diagnostic CT examinations exceeded the protocol's expected dose index range. In total, 10,970 records in the Dose Index Registry were statistically analyzed to establish both an upper and lower expected dose index for each protocol. All 2015 studies to date were then retrospectively reviewed to identify examinations whose total examination dose index exceeded the protocol's defined upper threshold. Each dose incident was then logged and reviewed per the new Joint Commission requirements. Facilities may leverage their participation in the ACR's Dose Index Registry to fully meet The Joint Commission's dose incident identification review and external benchmarking requirements. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Novel oxytocin receptor variants in laboring women requiring high doses of oxytocin.

    PubMed

    Reinl, Erin L; Goodwin, Zane A; Raghuraman, Nandini; Lee, Grace Y; Jo, Erin Y; Gezahegn, Beakal M; Pillai, Meghan K; Cahill, Alison G; de Guzman Strong, Cristina; England, Sarah K

    2017-08-01

    Although oxytocin commonly is used to augment or induce labor, it is difficult to predict its effectiveness because oxytocin dose requirements vary significantly among women. One possibility is that women requiring high or low doses of oxytocin have variations in the oxytocin receptor gene. To identify oxytocin receptor gene variants in laboring women with low and high oxytocin dosage requirements. Term, nulliparous women requiring oxytocin doses of ≤4 mU/min (low-dose-requiring, n = 83) or ≥20 mU/min (high-dose-requiring, n = 104) for labor augmentation or induction provided consent to a postpartum blood draw as a source of genomic DNA. Targeted-amplicon sequencing (coverage >30×) with MiSeq (Illumina) was performed to discover variants in the coding exons of the oxytocin receptor gene. Baseline relevant clinical history, outcomes, demographics, and oxytocin receptor gene sequence variants and their allele frequencies were compared between low-dose-requiring and high-dose-requiring women. The Scale-Invariant Feature Transform algorithm was used to predict the effect of variants on oxytocin receptor function. The Fisher exact or χ 2 tests were used for categorical variables, and Student t tests or Wilcoxon rank sum tests were used for continuous variables. A P value < .05 was considered statistically significant. The high-dose-requiring women had greater rates of obesity and diabetes and were more likely to have undergone labor induction and required prostaglandins. High-dose-requiring women were more likely to undergo cesarean delivery for first-stage arrest and less likely to undergo cesarean delivery for nonreassuring fetal status. Targeted sequencing of the oxytocin receptor gene in the total cohort (n = 187) revealed 30 distinct coding variants: 17 nonsynonymous, 11 synonymous, and 2 small structural variants. One novel variant (A243T) was found in both the low- and high-dose-requiring groups. Three novel variants (Y106H, A240_A249del, and P197delfs*206) resulting in an amino acid substitution, loss of 9 amino acids, and a frameshift stop mutation, respectively, were identified only in low-dose-requiring women. Nine nonsynonymous variants were unique to the high-dose-requiring group. These included 3 known variants (R151C, G221S, and W228C) and 6 novel variants (M133V, R150L, H173R, A248V, G253R, and I266V). Of these, R150L, R151C, and H173R were predicted by Scale-Invariant Feature Transform algorithm to damage oxytocin receptor function. There was no statistically significant association between the numbers of synonymous and nonsynonymous substitutions in the patient groups. Obesity, diabetes, and labor induction were associated with the requirement for high doses of oxytocin. We did not identify significant differences in the prevalence of oxytocin receptor variants between low-dose-requiring and high-dose-requiring women, but novel oxytocin receptor variants were enriched in the high-dose-requiring women. We also found 3 oxytocin receptor variants (2 novel, 1 known) that were predicted to damage oxytocin receptor function and would likely increase an individual's risk for requiring a high oxytocin dose. Further investigation of oxytocin receptor variants and their effects on protein function will inform precision medicine in pregnant women. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  18. The immunization data quality audit: verifying the quality and consistency of immunization monitoring systems.

    PubMed Central

    Ronveaux, O.; Rickert, D.; Hadler, S.; Groom, H.; Lloyd, J.; Bchir, A.; Birmingham, M.

    2005-01-01

    OBJECTIVE: To evaluate the consistency and quality of immunization monitoring systems in 27 countries during 2002-03 using standardized data quality audits (DQAs) that had been launched within the framework of the Global Alliance for Vaccines and Immunization. METHODS: The consistency of reporting systems was estimated by determining the proportion of third doses of diphtheria-tetanuspertussis (DTP-3) vaccine reported as being administered that could be verified by written documentation at health facilities and districts. The quality of monitoring systems was measured using quality indices for different components of the monitoring systems. These indices were applied to each level of the health service (health unit, district and national). FINDINGS: The proportion of verified DTP-3 doses was lower than 85% in 16 countries. Difficulties in verifying the doses administered often arose at the peripheral level of the health service, usually as the result of discrepancies in information between health units and their corresponding districts or because completed recording forms were not available from health units. All countries had weaknesses in their monitoring systems; these included the inconsistent use of monitoring charts; inadequate monitoring of vaccine stocks, injection supplies and adverse events; unsafe computer practices; and poor monitoring of completeness and timeliness of reporting. CONCLUSION: Inconsistencies in immunization data occur in many countries, hampering their ability to manage their immunization programmes. Countries should use these findings to strengthen monitoring systems so that data can reliably guide programme activities. The DQA is an innovative tool that provides a way to independently assess the quality of immunization monitoring systems at all levels of a health service and serves as a point of entry to make improvements. It provides a useful example for other global health initiatives. PMID:16175824

  19. Monitoring Haloperidol Plasma Concentration and Associated Adverse Events in Critically Ill Children With Delirium: First Results of a Clinical Protocol Aimed to Monitor Efficacy and Safety.

    PubMed

    Slooff, Valerie D; van den Dungen, Desley K; van Beusekom, Babette S; Jessurun, Naomi; Ista, Erwin; Tibboel, Dick; de Wildt, Saskia N

    2018-02-01

    As delirium in critically ill children is increasingly recognized, more children are treated with the antipsychotic drug haloperidol, while current dosing guidelines are lacking solid evidence and appear to be associated with a high risk of adverse events. We aim to report on the safety and efficacy of a recently implemented clinical dose-titration protocol with active monitoring of adverse events. From July 2014 until June 2015, when a potential delirium was identified by regular delirium scores and confirmed by a child psychiatrist, haloperidol was prescribed according to the Dutch Pediatric Formulary. Daily, adverse events were systematically assessed, haloperidol plasma concentrations were measured, and delirium symptoms followed. Dependent on the clinical response, plasma concentration, and adverse event, the dose was adjusted. A 28-bed tertiary PICU in the Netherlands. All patients admitted to the PICU diagnosed with delirium. Treatment with haloperidol according to a dose-titration protocol MEASUREMENTS AND MAIN RESULTS:: Thirteen children (median age [range] 8.3 yr [0.4-13.8 yr]) received haloperidol, predominantly IV (median dose [range] 0.027 mg/kg/d [0.005-0.085 mg/kg/d]). In all patients, pediatric delirium resolved, but five of 13 patients developed possible adverse event. These were reversed after biperiden (n = 2), discontinuing (n = 3), and/or lowering the dose (n = 3). Plasma concentrations were all below the presumed therapeutic threshold of 3-12 µg/L. Prospective systematic monitoring of adverse event in critically ill children receiving haloperidol revealed a significant proportion of possible adverse events. Adverse event developed despite low plasma concentrations and recommended dose administration in the majority of the patients. Our data suggest that haloperidol can potentially improve pediatric delirium, but it might also put patients at risk for developing adverse events.

  20. Monitoring of timely and delayed vaccinations: a nation-wide registry-based study of Norwegian children aged < 2 years.

    PubMed

    Riise, Øystein Rolandsen; Laake, Ida; Bergsaker, Marianne Adeleide Riise; Nøkleby, Hanne; Haugen, Inger Lise; Storsæter, Jann

    2015-11-13

    Delayed vaccinations increase the risk for vaccine preventable diseases (VPDs). Monitoring of delayed vaccinations by using a national immunisation registry has not been studied in countries recommending a two-dose (3 and 5 months of age) primary series of e.g., pertussis vaccine. Surveillance/monitoring of all vaccinations may improve vaccination programmes functioning. We obtained information from the Norwegian immunisation registry (SYSVAK) on all programme vaccinations received at age up to 730 days in children born in 2010 (n = 63,382). Timely vaccinations were received up to 7 days after the recommended age. Vaccinations were considered delayed if they were received more than one month after the recommended age in the schedule. In vaccinated children, timely administration of the subsequent three doses of pertussis and one dose of measles occurred in 73.8, 47.6, 53.6 and 43.5 % respectively. Delay for one or more programme vaccinations (diphtheria, tetanus, pertussis, polio, Haemophilus influenza type B, invasive pneumococcal disease, measles, mumps or rubella) was present in 28,336 (44.7 %) children. Among those who were delayed the mean duration was 139 days. The proportion of children that had vaccinations delayed differed among counties (range 37.4 %-57.8 %). Immigrant children were more frequently delayed 52.3 % vs. 43.1 %, RR 1.21 (95 % CI 1.19, 1.24). Children scheduled for vaccines in the summer holiday month (July) were more frequently delayed than others (1(st) dose pertussis vaccine 6.5 % vs. 3.9 % RR 1.65 (95 % CI 1.48, 1.85). Priming against pertussis (2(nd) dose), pneumococcal (2(nd) dose) and measles (1(st) dose) was delayed in 16.8, 18.6 and 29.3 % respectively. Vaccinations were frequently delayed. Delayed vaccinations differed among counties and occurred more frequently during the summer vacation (July) and in the immigrant population. Monitoring improves programme surveillance and may be used on an annual basis.

  1. Biological monitoring to determine worker dose in a butadiene processing plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bechtold, W.E.; Hayes, R.B.

    1995-12-01

    Butadiene (BD) is a reactive gas used extensively in the rubber industry and is also found in combustion products. Although BD is genotoxic and acts as an animal carcinogen, the evidence for carcinogenicity in humans is limited. Extrapolation from animal studies on BD carcinogenicity to risk in humans has been controversial because of uncertainties regarding relative biologic exposure and related effects in humans vs. experimental animals. To reduce this uncertainty, a study was designed to characterize exposure to BD at a polymer production facility and to relate this exposure to mutational and cytogenetic effects. Biological monitoring was used to bettermore » assess the internal dose of BD received by the workers. Measurement of 1,2-dihydroxy-4-(N-acetylcysteinyl) butane (M1) in urine served as the biomarker in this study. M1 has been shown to correlate with area monitoring in previous studies. Most studies that relate exposure to a toxic chemical with its biological effects rely on exposure concentration as the dose metric; however, exposure concentration may or may not reflect the actual internal dose of the chemical.« less

  2. Implementation and application of an interactive user-friendly validation software for RADIANCE

    NASA Astrophysics Data System (ADS)

    Sundaram, Anand; Boonn, William W.; Kim, Woojin; Cook, Tessa S.

    2012-02-01

    RADIANCE extracts CT dose parameters from dose sheets using optical character recognition and stores the data in a relational database. To facilitate validation of RADIANCE's performance, a simple user interface was initially implemented and about 300 records were evaluated. Here, we extend this interface to achieve a wider variety of functions and perform a larger-scale validation. The validator uses some data from the RADIANCE database to prepopulate quality-testing fields, such as correspondence between calculated and reported total dose-length product. The interface also displays relevant parameters from the DICOM headers. A total of 5,098 dose sheets were used to test the performance accuracy of RADIANCE in dose data extraction. Several search criteria were implemented. All records were searchable by accession number, study date, or dose parameters beyond chosen thresholds. Validated records were searchable according to additional criteria from validation inputs. An error rate of 0.303% was demonstrated in the validation. Dose monitoring is increasingly important and RADIANCE provides an open-source solution with a high level of accuracy. The RADIANCE validator has been updated to enable users to test the integrity of their installation and verify that their dose monitoring is accurate and effective.

  3. The role of a microDiamond detector in the dosimetry of proton pencil beams.

    PubMed

    Gomà, Carles; Marinelli, Marco; Safai, Sairos; Verona-Rinati, Gianluca; Würfel, Jan

    2016-03-01

    In this work, the performance of a microDiamond detector in a scanned proton beam is studied and its potential role in the dosimetric characterization of proton pencil beams is assessed. The linearity of the detector response with the absorbed dose and the dependence on the dose-rate were tested. The depth-dose curve and the lateral dose profiles of a proton pencil beam were measured and compared to reference data. The feasibility of calibrating the beam monitor chamber with a microDiamond detector was also studied. It was found the detector reading is linear with the absorbed dose to water (down to few cGy) and the detector response is independent of both the dose-rate (up to few Gy/s) and the proton beam energy (within the whole clinically-relevant energy range). The detector showed a good performance in depth-dose curve and lateral dose profile measurements; and it might even be used to calibrate the beam monitor chambers-provided it is cross-calibrated against a reference ionization chamber. In conclusion, the microDiamond detector was proved capable of performing an accurate dosimetric characterization of proton pencil beams. Copyright © 2015. Published by Elsevier GmbH.

  4. Feasibility of tuberculosis treatment monitoring by video directly observed therapy: a binational pilot study.

    PubMed

    Garfein, R S; Collins, K; Muñoz, F; Moser, K; Cerecer-Callu, P; Raab, F; Rios, P; Flick, A; Zúñiga, M L; Cuevas-Mota, J; Liang, K; Rangel, G; Burgos, J L; Rodwell, T C; Patrick, K

    2015-09-01

    Although directly observed therapy (DOT) is recommended worldwide for monitoring anti-tuberculosis treatment, transportation and personnel requirements limit its use. To evaluate the feasibility and acceptability of 'video DOT' (VDOT), which allows patients to record and transmit medication ingestion via videos watched remotely by health care providers to document adherence. We conducted a single-arm trial among tuberculosis (TB) patients in San Diego, California, USA, (n = 43) and Tijuana, Mexico (n = 9) to represent high- and low-resource settings. Pre-/post-treatment interviews assessed participant characteristics and experiences. Adherence was defined as the proportion of observed doses to expected doses. The mean age was 37 years (range 18-86), 50% were male, and 88% were non-Caucasian. The mean duration of VDOT use was 5.5 months (range 1-11). Adherence was similar in San Diego (93%) and Tijuana (96%). Compared to time on in-person DOT, 92% preferred VDOT, 81% thought VDOT was more confidential, 89% never/rarely had problems recording videos, and 100% would recommend VDOT to others. Seven (13%) participants were returned to in-person DOT and six (12%) additional participants had their phones lost, broken or stolen. VDOT was feasible and acceptable, with high adherence in both high- and low-resource settings. Efficacy and cost-effectiveness studies are needed.

  5. Radon measurements and dose estimate of workers in a manganese ore mine.

    PubMed

    Shahrokhi, Amin; Vigh, Tamás; Németh, Csaba; Csordás, Anita; Kovács, Tibor

    2017-06-01

    In the new European Basic Safety Standard (EU-BSS), a new reference level for indoor radon concentration in workplaces has recommended that the annual average activity concentration of indoor radon shall not be higher than 300Bqm -3 . This paper describes the radon concentration level in an underground workplace (manganese ore mine) over long time intervals (4 years). Several common radon monitors devices - including NRPB and Raduet (as a passive method based on CR-39), AlphaGUARD PQ 2000Pro, SARAD EQF3220, TESLA and Pylon WLX (as active methods) - were used for continuous radon measurements. The output results were used, first, to comprised the result of each device, based on conditions present in underground mines; Second, to have comprehensive measurements about all factors that cause workers exposure to radiation (each monitoring device specified for a unique measurement). The results indicate that the mine's staff had successful efforts to reach the strict requirement of the new EU-BSS, and the average annual radon activity concentrations during the working hours were below 300Bqm -3 in the investigated period. The paper presents the effective dose calculations; applying different equilibrium factors suggested by the literature and calculated basing on our measurements at the site, concluding that the differences could be about threefold. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Charge amplifier with bias compensation

    DOEpatents

    Johnson, Gary W.

    2002-01-01

    An ion beam uniformity monitor for very low beam currents using a high-sensitivity charge amplifier with bias compensation. The ion beam monitor is used to assess the uniformity of a raster-scanned ion beam, such as used in an ion implanter, and utilizes four Faraday cups placed in the geometric corners of the target area. Current from each cup is integrated with respect to time, thus measuring accumulated dose, or charge, in Coulombs. By comparing the dose at each corner, a qualitative assessment of ion beam uniformity is made possible. With knowledge of the relative area of the Faraday cups, the ion flux and areal dose can also be obtained.

  7. Effects of acepromazine and trazodone on anesthetic induction dose of propofol and cardiovascular variables in dogs undergoing general anesthesia for orthopedic surgery.

    PubMed

    Murphy, Lindsey A; Barletta, Michele; Graham, Lynelle F; Reichl, Lorna J; Duxbury, Margaret M; Quandt, Jane E

    2017-02-15

    OBJECTIVE To compare the doses of propofol required to induce general anesthesia in dogs premedicated with acepromazine maleate or trazodone hydrochloride and compare the effects of these premedicants on cardiovascular variables in dogs anesthetized for orthopedic surgery. DESIGN Prospective, randomized study. ANIMALS 30 systemically healthy client-owned dogs. PROCEDURES 15 dogs received acepromazine (0.01 to 0.03 mg/kg [0.005 to 0.014 mg/lb], IM) 30 minutes before anesthetic induction and 15 received trazodone (5 mg/kg [2.27 mg/lb] for patients > 10 kg or 7 mg/kg [3.18 mg/lb] for patients ≤ 10 kg, PO) 2 hours before induction. Both groups received morphine sulfate (1 mg/kg [0.45 mg/lb], IM) 30 minutes before induction. Anesthesia was induced with propofol (4 to 6 mg/kg [1.82 to 2.73 mg/lb], IV, to effect) and maintained with isoflurane or sevoflurane in oxygen. Bupivacaine (0.5 mg/kg [0.227 mg/lb]) and morphine (0.1 mg/kg [0.045 mg/lb]) were administered epidurally. Dogs underwent tibial plateau leveling osteotomy (n = 22) or tibial tuberosity advancement (8) and were monitored throughout anesthesia. Propofol induction doses and cardiovascular variables (heart rate and systemic, mean, and diastolic arterial blood pressures) were compared between groups. RESULTS The mean dose of propofol required for anesthetic induction and all cardiovascular variables evaluated did not differ between groups. Intraoperative hypotension developed in 6 and 5 dogs of the acepromazine and trazodone groups, respectively; bradycardia requiring intervention developed in 3 dogs/group. One dog that received trazodone had priapism 24 hours later and was treated successfully. No other adverse effects were reported. CONCLUSIONS AND CLINICAL RELEVANCE At the described dosages, cardiovascular effects of trazodone were similar to those of acepromazine in healthy dogs undergoing anesthesia for orthopedic surgery.

  8. Dose requirements of alfentanil to eliminate autonomic responses during rapid-sequence induction with thiopental 4 mg/kg and rocuronium 0.6 mg/kg.

    PubMed

    Abou-Arab, Mohammad H; Rostrup, Morten; Heier, Tom

    2016-12-01

    Opioids are integral part of anesthesia induction, but information on optimal dosing is limited. We aimed to determine doses of alfentanil needed to eliminate increases in 5 autonomic response variables (plasma concentrations of epinephrine, norepinephrine and vasopressin, arterial blood pressure [ABP], and heart rate) during rapid-sequence induction of anesthesia with thiopental 4 mg/kg and rocuronium 0.6 mg/kg. Prospective, randomized, observer-blinded, interventional clinical study. Large academic institution. Eighty-four healthy patients, aged 18 to 55 years, received 1 of 7 assessor-blinded doses of alfentanil (0, 10, 20, 30, 40, 50, and 60 μg/kg) together with thiopental 4 mg/kg and rocuronium 0.6 mg/kg, administered in rapid succession (15 seconds). Laryngoscopy was initiated 40 seconds after rocuronium, and tracheal intubation was concluded within 15 seconds thereafter. An indwelling radial artery catheter was used for hemodynamic monitoring and blood sampling. Relationships between alfentanil dose and response variables were tested with linear regression, and the influence of covariates (sex, body weight, and age) was determined. Alfentanil dose needed to prevent increases in ABP >10% above baseline with 95% probability was estimated with logistic regression. Significant relationships were determined between alfentanil dose and response variables. Clinically interesting influence of covariates was not found. Alfentanil 55 μg/kg was needed to prevent increases in ABP postintubation >10% above baseline with 95% probability. One individual needed a bolus of vasopressor postintubation. Optimal control of autonomic responses during rapid-sequence induction was achieved with clinically relevant doses of alfentanil in healthy patients anesthetized with thiopental 4 mg/kg and rocuronium 0.6 mg/kg. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Promoting Abstinence from Cocaine and Heroin with a Methadone Dose Increase and a Novel Contingency

    PubMed Central

    Schmittner, John; Umbricht, Annie; Schroeder, Jennifer R.; Moolchan, Eric T.; Preston, Kenzie L.

    2010-01-01

    To test whether a combination of contingency management and methadone dose increase would promote abstinence from heroin and cocaine, we conducted a randomized controlled trial using a 2 X 3 (Dose X Contingency) factorial design in which dose assignment was double-blind. Participants were 252 heroin- and cocaine-abusing outpatients on methadone maintenance. They were randomly assigned to methadone dose (70 or 100 mg/day, double blind) and voucher condition (noncontingent, contingent on cocaine-negative urines, or “split”). The “split” contingency was a novel contingency that reinforced abstinence from either drug while doubly reinforcing simultaneous abstinence from both: the total value of incentives was “split” between drugs to contain costs. The main outcome measures were percentages of urine specimens negative for heroin, cocaine, and both simultaneously; these were monitored during a 5-week baseline of standard treatment (to determine study eligibility), a 12-week intervention, and a 10-week maintenance phase (to examine intervention effects in return-to-baseline conditions). DSM-IV criteria for ongoing drug dependence were assessed at study exit. Urine-screen results showed that the methadone dose increase reduced heroin use but not cocaine use. The Split 100mg group was the only group to achieve a longer duration of simultaneous negatives than its same-dose Noncontingent control group. The frequency of DSM-IV opiate and cocaine dependence diagnoses decreased in the active intervention groups. For a split contingency to promote simultaneous abstinence from cocaine and heroin, a relatively high dose of methadone appears necessary but not sufficient; an increase in overall incentive amount may also be required. PMID:19101098

  10. Comprehensive clinical commissioning and validation of the RayStation treatment planning system for proton therapy with active scanning and passive treatment techniques.

    PubMed

    Bäumer, C; Geismar, D; Koska, B; Kramer, P H; Lambert, J; Lemke, M; Plaude, S; Pschichholz, L; Qamhiyeh, S; Schiemann, A; Timmermann, B; Vermeren, X

    2017-11-01

    To commission the treatment planning system (TPS) RayStation for proton therapy including beam models for spot scanning and for uniform scanning. Tests consist of procedures from ESTRO booklet number 7, the German DIN for constancy checks of TPSs, and extra tests checking the dose perturbation function. The dose distributions within patients were verified in silico by a comparison of 65 clinical treatment plans with the TPS XiO. Dose-volume parameters, dose differences, and three-dimensional gamma-indices serve as measures of similarity. The monthly constancy checks of Raystation have been automatized with a script. The basic functionality of the software complies with ESTRO booklet number 7. For a few features minor enhancements are suggested. The dose distribution in RayStation agrees with the calculation in XiO. This is supported by a gamma-index (3mm/3%) pass rate of >98.9% (median over 59 plans) for the volume within the 20% isodose line and a difference of <0.3% of V 95 of the PTV (median over 59 plans). If spot scanning is used together with a range shifter, the dose level calculated by RayStation can be off by a few percent. RayStation can be used for the creation of clinical proton treatment plans. Compared to XiO RayStation has an improved modelling of the lateral dose fall-off in passively delivered fields. For spot scanning fields with range shifter blocks an empirical adjustment of monitor units is required. The computation of perturbed doses also allows the evaluation of the robustness of a treatment plan. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Population Pharmacokinetics of Intravenous Methotrexate in Patients with Hematological Malignancies: Utilization of Routine Clinical Monitoring Parameters.

    PubMed

    Nader, Ahmed; Zahran, Noran; Alshammaa, Aya; Altaweel, Heba; Kassem, Nancy; Wilby, Kyle John

    2017-04-01

    Clinical response to methotrexate in cancer is variable and depends on several factors including serum drug exposure. This study aimed to develop a population pharmacokinetic model describing methotrexate disposition in cancer patients using retrospective chart review data available from routine clinical practice. A retrospective review of medical records was conducted for cancer patients in Qatar. Relevant data (methotrexate dosing/concentrations from multiple occasions, patient history, and laboratory values) were extracted and analyzed using NONMEM VII ® . A population pharmacokinetic model was developed and used to estimate inter-individual and inter-occasion variability terms on methotrexate pharmacokinetic parameters, as well as patient factors affecting methotrexate pharmacokinetics. Methotrexate disposition was described by a two-compartment model with clearance (CL) of 15.7 L/h and central volume of distribution (V c ) of 79.2 L. Patient weight and hematocrit levels were significant covariates on methotrexate V c and CL, respectively. Methotrexate CL changed by 50 % with changes in hematocrit levels from 23 to 50 %. Inter-occasion variability in methotrexate CL was estimated for patients administered the drug on multiple occasions (48 and 31 % for 2nd and 3rd visits, respectively). Therapeutic drug monitoring data collected during routine clinical practice can provide a useful tool for understanding factors affecting methotrexate pharmacokinetics. Patient weight and hematocrit levels may play a clinically important role in determining methotrexate serum exposure and dosing requirements. Future prospective studies are needed to validate results of the developed model and evaluate its usefulness to predict methotrexate exposure and optimize dosing regimens.

  12. Upper-Bound Radiation Dose Assessment for Military Personnel at McMurdo Station, Antarctica, between 1962 and 1979

    DTIC Science & Technology

    2013-06-01

    Belvoir, VA 22060-6201 10. SPONSOR/MONITOR’S ACRONYM(S) DTRA J9-NTSN 11 . SPONSORING/MONITORING AGENCY REPORT NUMBER DTRA-TR-12-003 12...average tritium activity in drinking water samples (Bq L-1) ......................... 43 Table 11 . Parameter values and assumptions for estimating...the ground, roads and ship loading areas .......................... 59 11 Table 23. Parameter values and assumptions for the internal dose from

  13. Hazelwood Interim Storage Site annual environmental report for calendar year 1991, Hazelwood, Missouri. [Hazelwood Interim Storage Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-09-01

    This document describes the environmental monitoring program at the Hazelwood Interim Storage Site (HISS) and surrounding area, implementation of the program, and monitoring results for 1991. Environmental monitoring of HISS began in 1984 when the site was assigned to the US Department of Energy (DOE) as part of the decontamination research and development project authorized by Congress under the 1984 Energy and Water Development Appropriations Act. DOE placed responsibility for HISS under the Formerly Utilized Sites Remedial Action Program (FUSRAP), a DOE program to decontaminate or otherwise control sites where residual radioactive materials remain from the early years of themore » nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The environmental monitoring program at HISS includes sampling networks for radon concentrations in air; external gamma radiation exposure; and radium-226, thorium-230, and total uranium concentrations in surface water, sediment, and groundwater. Additionally, several nonradiological parameters are measured in groundwater. Monitoring results are compared with applicable Environmental Protection Agency standards, DOE derived concentration guides (DCGs), dose limits, and other requirements in DOE orders. Environmental standards and DCGs are established to protect public health and the environment.« less

  14. Transitioning Patients With Iron Overload From Exjade to Jadenu.

    PubMed

    Tinsley, Sara M; Hoehner-Cooper, Christine M

    Iron overload is a concern for patients who require chronic transfusions as a result of inherited or acquired anemias, including sickle cell disease, thalassemia, and myelodysplastic syndromes. Iron chelation therapy (ICT) is the primary treatment for iron overload in these patients. The ICT deferasirox, which has been available as an oral dispersible tablet for liquid suspension, is now also available as a once-daily, film-coated tablet (FCT). Deferasirox FCT allows greater convenience and may be associated with fewer gastrointestinal side effects versus the original formulation. Dose adjustment increments, determined by titration monitoring, are lower for the FCT because of greater bioavailability.

  15. Pediatric ambulatory anesthesia.

    PubMed

    August, David A; Everett, Lucinda L

    2014-06-01

    Pediatric patients often undergo anesthesia for ambulatory procedures. This article discusses several common preoperative dilemmas, including whether to postpone anesthesia when a child has an upper respiratory infection, whether to test young women for pregnancy, which children require overnight admission for apnea monitoring, and the effectiveness of nonpharmacological techniques for reducing anxiety. Medication issues covered include the risks of anesthetic agents in children with undiagnosed weakness, the use of remifentanil for tracheal intubation, and perioperative dosing of rectal acetaminophen. The relative merits of caudal and dorsal penile nerve block for pain after circumcision are also discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Measurement of dose distribution in the spherical phantom onboard the ISS-KIBO module -MATROSHKA-R in KIBO-

    NASA Astrophysics Data System (ADS)

    Kodaira, Satoshi; Kawashima, Hajime; Kurano, Mieko; Uchihori, Yukio; Nikolaev, Igor; Ambrozova, Iva; Kitamura, Hisashi; Kartsev, Ivan; Tolochek, Raisa; Shurshakov, Vyacheslav

    The measurement of dose equivalent and effective dose during manned space missions on the International Space Station (ISS) is important for evaluating the risk to astronaut health and safety when exposed to space radiation. The dosimetric quantities are constantly changing and strongly depend on the level of solar activity and the various spacecraft- and orbit-dependent parameters such as the shielding distribution in the ISS module, location of the spacecraft within its orbit relative to the Earth, the attitude (orientation) and altitude. Consequently, the continuous monitoring of dosimetric quantities is required to record and evaluate the personal radiation dose for crew members during spaceflight. The dose distributions in the phantom body and on its surface give crucial information to estimate the dose equivalent in the human body and effective dose in manned space mission. We have measured the absorbed dose and dose equivalent rates using passive dosimeters installed in the spherical phantom in Japanese Experiment Module (“KIBO”) of the ISS in the framework of Matroshka-R space experiment. The exposure duration was 114 days from May 21 to September 12, 2012. The phantom consists of tissue-equivalent material covered with a poncho jacket with 32 pockets on its surface and 20 container rods inside of the phantom. The phantom diameter is 35 cm and the mass is 32 kg. The passive dosimeters consisted of a combination of luminescent detectors of Al _{2}O _{3};C OSL and CaSO _{4}:Dy TLD and CR-39 plastic nuclear track detectors. As one of preliminary results, the dose distribution on the phantom surface measured with OSL detectors installed in the jacket pockets is found to be ranging from 340 muGy/day to 260 muGy/day. In this talk, we will present the detail dose distributions, and variations of LET spectra and quality factor obtained outside and inside of the spherical phantom installed in the ISS-KIBO.

  17. Effect of high-dose irradiation on the optically stimulated luminescence of Al2O3:C

    NASA Technical Reports Server (NTRS)

    Yukihara, E. G.; Whitley, V. H.; McKeever, S. W. S.; Akselrod, A. E.; Akselrod, M. S.

    2004-01-01

    This paper examines the effect of high-dose irradiation on the optically stimulated luminescence (OSL) of Al2O3:C, principally on the shape of the OSL decay curve and on the OSL sensitivity. The effect of the degree of deep trap filling on the OSL was also studied by monitoring the sensitivity changes after doses of beta irradiation and after step-annealing of samples previously irradiated with high doses. The OSL response to dose shows a linear-supralinear-saturation behavior, with a decrease in the response for doses higher than those required for saturation. This behavior correlates with the sensitivity changes observed in the samples annealed only to 773 K, which show sensitization for doses up to 20-50 Gy and desensitization for higher doses. Data from the step-annealing study leads to the suggestion that the sensitization is caused by the filling of deep electron traps, which become thermally unstable at 1100-1200 K, whereas the desensitization is caused by the filling of deep hole traps, which become thermally unstable at 800-875 K, along with a concomitant decrease in the concentration of recombination centers (F+ -centers). Changes in the shape of the OSL decay curves are also observed at high doses, the decay becoming faster as the dose increases. These changes in the OSL decay curves are discussed in terms of multiple overlapping components, each characterized by different photoionization cross-sections. However, using numerical solutions of the rate equations for a simple model consisting of a main trap and a recombination center, it is shown that the kinetics of OSL process may also be partially responsible for the changes in the OSL curves at high doses in Al2O3:C. Finally, the implication of these results for the dosimetry of heavy charged particles is discussed. c2004 Elsevier Ltd. All rights reserved.

  18. Oak Ridge Reservation annual site environmental report for 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koncinski, W.S.

    1996-09-01

    This report presents the details of the environmental monitoring and management program for the Oak Ridge Reservation. Topics discussed include: site background, climate, and operations; environmental compliance strategies; effluent monitoring; environmental management program including environmental restoration, decontamination and decommissioning, technology development, and public involvement; effluent monitoring of airborne discharges, liquid discharges, toxicity control and monitoring, biological monitoring and abatement; environmental surveillance which encompasses meteorological monitoring, ambient air monitoring, surface water monitoring, soils monitoring, sediment monitoring, and contamination of food stuffs monitoring; radiation doses; chemical exposures; ground water monitoring; and quality assurance.

  19. The introduction of the meningococcal B (MenB) vaccine (Bexsero®) into the national infant immunisation programme--New challenges for public health.

    PubMed

    Ladhani, Shamez N; Campbell, Helen; Parikh, Sydel R; Saliba, Vanessa; Borrow, Ray; Ramsay, Mary

    2015-12-01

    The United Kingdom is the first country to introduce Bexsero(®) (GSK Biologicals), a multicomponent, protein-based vaccine against meningococcal group B (MenB), into the national infant immunisation programme. This vaccine is like no other licensed vaccine and poses a number of implementation and surveillance challenges in England. From 01 September 2015, UK infants were offered a reduced two dose primary immunisation schedule at 2 and 4 months followed by a booster at 12 months. Because of high rates of fever post-vaccination, parents were advised to give their infants three doses of prophylactic paracetamol, with the first dose given as soon as possible after the primary MenB vaccination dose. Since the vaccine only protects against 73-88% of MenB strains causing invasive disease in England, clinical isolates and PCR-positive samples will require extensive characterisation by the Meningococcal Reference Unit (MRU) at Public Health England (PHE) in order to monitor vaccine effectiveness and identify potential vaccine failures. PHE is also conducting detailed clinical and epidemiological surveillance to assess the impact of the MenB immunisation programme on the morbidity and mortality associated with invasive meningococcal disease in infants and young children. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  20. Assessing vaccination coverage in infants, survey studies versus the Flemish immunisation register: achieving the best of both worlds.

    PubMed

    Braeckman, Tessa; Lernout, Tinne; Top, Geert; Paeps, Annick; Roelants, Mathieu; Hoppenbrouwers, Karel; Van Damme, Pierre; Theeten, Heidi

    2014-01-09

    Infant immunisation coverage in Flanders, Belgium, is monitored through repeated coverage surveys. With the increased use of Vaccinnet, the web-based ordering system for vaccines in Flanders set up in 2004 and linked to an immunisation register, this database could become an alternative to quickly estimate vaccination coverage. To evaluate its current accuracy, coverage estimates generated from Vaccinnet alone were compared with estimates from the most recent survey (2012) that combined interview data with data from Vaccinnet and medical files. Coverage rates from registrations in Vaccinnet were systematically lower than the corresponding estimates obtained through the survey (mean difference 7.7%). This difference increased by dose number for vaccines that require multiple doses. Differences in administration date between the two sources were observed for 3.8-8.2% of registered doses. Underparticipation in Vaccinnet thus significantly impacts on the register-based immunisation coverage estimates, amplified by underregistration of administered doses among vaccinators using Vaccinnet. Therefore, survey studies, despite being labour-intensive and expensive, currently provide more complete and reliable results than register-based estimates alone in Flanders. However, further improvement of Vaccinnet's completeness will likely allow more accurate estimates in the nearby future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. A case series of re-establishment of neuromuscular block with rocuronium after sugammadex reversal.

    PubMed

    Iwasaki, Hajime; Sasakawa, Tomoki; Takahoko, Kenichi; Takagi, Shunichi; Nakatsuka, Hideki; Suzuki, Takahiro; Iwasaki, Hiroshi

    2016-06-01

    We report the use of rocuronium to re-establish neuromuscular block after reversal with sugammadex. The aim of this study was to investigate the relationship between the dose of rocuronium needed to re-establish neuromuscular block and the time interval between sugammadex administration and re-administration of rocuronium. Patients who required re-establishment of neuromuscular block within 12 h after the reversal of rocuronium-induced neuromuscular block with sugammadex were included. After inducing general anesthesia and placing the neuromuscular monitor, the protocol to re-establish neuromuscular block was as follows. An initial rocuronium dose of 0.6 mg/kg was followed by additional 0.3 mg/kg doses every 2 min until train-of-four responses were abolished. A total of 11 patients were enrolled in this study. Intervals between sugammadex and second rocuronium were 12-465 min. Total dose of rocuronium needed to re-establish neuromuscular block was 0.6-1.2 mg/kg. 0.6 mg/kg rocuronium re-established neuromuscular block in all patients who received initial sugammadex more than 3 h previously. However, when the interval between sugammadex and second rocuronium was less than 2 h, more than 0.6 mg/kg rocuronium was necessary to re-establish neuromuscular block.

  2. Design of a transdermal delivery system for aspirin as an antithrombotic drug.

    PubMed

    Ammar, H O; Ghorab, M; El-Nahhas, S A; Kamel, R

    2006-12-11

    Aspirin has become the gold standard to which newer antiplatelet drugs are compared for reducing risks of cardiovascular diseases, while keeping low cost. Oral aspirin has a repertoire of gastrointestinal side effects even at low doses and requires high frequent dosing because it undergoes extensive presystemic metabolism. Transdermal delivery offers an alternative route that bypasses the gut and may be more convenient and safer for aspirin delivery especially during long-term use. This study comprised formulation of aspirin in different topical bases. Release studies revealed that hydrocarbon gel allowed highest drug release. In vitro permeation studies revealed high drug permeation from hydrocarbon gel. Several chemical penetration enhancers were monitored for augmenting the permeation from this base. Combination of propylene glycol and alcohol showed maximum enhancing effect and, hence, was selected for biological investigation. The biological performance of the selected formulation was assessed by measuring the inhibition of platelet aggregation relevant to different dosage regimens aiming to minimize both drug dose and frequency of application. The results demonstrated the feasibility of successfully influencing platelet function and revealed that the drug therapeutic efficacy in transdermal delivery system is dose independent. Biological performance was re-assessed after storage and the results revealed stability and persistent therapeutic efficacy.

  3. Plasma, salivary and urinary cortisol levels following physiological and stress doses of hydrocortisone in normal volunteers.

    PubMed

    Jung, Caroline; Greco, Santo; Nguyen, Hanh H T; Ho, Jui T; Lewis, John G; Torpy, David J; Inder, Warrick J

    2014-11-26

    Glucocorticoid replacement is essential in patients with primary and secondary adrenal insufficiency, but many patients remain on higher than recommended dose regimens. There is no uniformly accepted method to monitor the dose in individual patients. We have compared cortisol concentrations in plasma, saliva and urine achieved following "physiological" and "stress" doses of hydrocortisone as potential methods for monitoring glucocorticoid replacement. Cortisol profiles were measured in plasma, saliva and urine following "physiological" (20 mg oral) or "stress" (50 mg intravenous) doses of hydrocortisone in dexamethasone-suppressed healthy subjects (8 in each group), compared to endogenous cortisol levels (12 subjects). Total plasma cortisol was measured half-hourly, and salivary cortisol and urinary cortisol:creatinine ratio were measured hourly from time 0 (between 0830 and 0900) to 5 h. Endogenous plasma corticosteroid-binding globulin (CBG) levels were measured at time 0 and 5 h, and hourly from time 0 to 5 h following administration of oral or intravenous hydrocortisone. Plasma free cortisol was calculated using Coolens' equation. Plasma, salivary and urine cortisol at 2 h after oral hydrocortisone gave a good indication of peak cortisol concentrations, which were uniformly supraphysiological. Intravenous hydrocortisone administration achieved very high 30 minute cortisol concentrations. Total plasma cortisol correlated significantly with both saliva and urine cortisol after oral and intravenous hydrocortisone (P <0.0001, correlation coefficient between 0.61 and 0.94). There was no difference in CBG levels across the sampling period. An oral dose of hydrocortisone 20 mg is supraphysiological for routine maintenance, while stress doses above 50 mg 6-hourly would rarely be necessary in managing acute illness. Salivary cortisol and urinary cortisol:creatinine ratio may provide useful alternatives to plasma cortisol measurements to monitor replacement doses in hypoadrenal patients.

  4. SU-E-T-492: Influence of Clipping PTV in Build-Up Region On IMRT Plan Quality and Deliverability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, S; Manigandan, D; Sahai, P

    2015-06-15

    Purpose: To study the influence of clipping PTV from body contour on plan quality and deliverability in build-up region for superficial target. Methods: Five previously treated patients of post-operative carcinoma of parotid were re-planned for IMRT (6MV X-rays, sliding window technique, five fields and 60Gy/30 fractions) using eclipse treatment planning system (TPS) by keeping dose volume constraints and all other parameters constant, only PTV was clipped from body contour by 0mm, 1mm, 2mm and 3mm respectively. Planned fluence was transferred to previously scanned solid water phantom by placing I’matriXX array at 0.5cm depth (2mm slab+3mm inherent). Fluence was delivered bymore » Varian CL2300C/D linac at 99.5cm source to detector distance. Measured fluence was compared with TPS dose plane using 2D gamma evaluation using 3%/3mm DTA criteria. Total MU (monitor unit) required to deliver a plan was also noted. For plan quality, PTV, maximum-dose, minimum-dose, coverage index (CI=PTV volume covered by prescription dose/PTV) and heterogeneity index HI=D5/D95 were analyzed using dose volume histogram (DVH). Results: The Result of gamma function analysis for I’matriXX and TPS were 97.63±1.79%, 97.48±0.99, 98.08±0.89% and 98.01±0.78% at 0.5cm build-up depth for 0, 1, 2 and 3mm PTV clipping, respectively. I’matriXX measured dose was higher compared to TPS. Total MU required for delivering a plan were 552±61, 503±47, 436±24 and 407±22. Maximum-dose to PTV was 6635.80±62.01cGy, 6635.80±40.60cGy, 6608.43±51.07cGy and 6564.20±28.51cGy. Similarly, minimum-dose to PTV was 3306.23±458.56cGy, 3546.57±721.01cGy, 4591.43±298.81cGy and 4861.90±412.40cGy. CI was 0.9347±0.020, 0.9398±0.021, 0.9448±0.022 and 0.9481±0.021. Similarly, HI was 1.089±0.015, 1.084±0.014, 1.078±0.009 and 1.074±0.008 for 0, 1, 2 and 3mm PTV clipping, respectively. Conclusion: Gamma function analysis resulted in almost similar results. However, I’matriXX was overestimating the dose compared to TPS. MU required to deliver a plan decreases with increase in PTV clipping. CI, PTV minimum-dose and plan homogeneity increases with increase in PTV clipping from skin.« less

  5. Variation in Prescribing Patterns and Therapeutic Drug Monitoring of Intravenous Busulfan in Pediatric Hematopoietic Cell Transplant Recipients

    PubMed Central

    McCune, Jeannine S.; Baker, K. Scott; Blough, David K.; Gamis, Alan; Bemer, Meagan J.; Kelton-Rehkopf, Megan C.; Winter, Laura; Barrett, Jeffrey S.

    2016-01-01

    Personalizing intravenous (IV) busulfan doses in children using therapeutic drug monitoring (TDM) is an integral component of hematopoietic cell transplant. The authors sought to characterize initial dosing and TDM of IV busulfan, along with factors associated with busulfan clearance, in 729 children who underwent busulfan TDM from December 2005 to December 2008. The initial IV busulfan dose in children weighing ≤12 kg ranged 4.8-fold, with only 19% prescribed the package insert dose of 1.1 mg/kg. In those children weighing >12 kg, the initial dose ranged 5.4-fold, and 79% were prescribed the package insert dose. The initial busulfan dose achieved the target exposure in only 24.3% of children. A wide range of busulfan exposures were targeted for children with the same disease (eg, 39 target busulfan exposures for the 264 children diagnosed with acute myeloid leukemia). Considerable heterogeneity exists regarding when TDM is conducted and the number of pharmacokinetic samples obtained. Busulfan clearance varied by age and dosing frequency but not by underlying disease. The authors’ group is currently evaluating how using population pharmacokinetics to optimize initial busulfan dose and TDM (eg, limited sampling schedule in conjunction with maximum a posteriori Bayesian estimation) may affect clinical outcomes in children. PMID:23444282

  6. Novel Approaches for Visualizing and Analyzing Dose-Timing Data from Electronic Drug Monitors, or "How the 'Broken Window' Theory Pertains to ART Adherence".

    PubMed

    Gill, Christopher J; DeSilva, Mary Bachman; Hamer, Davidson H; Keyi, Xu; Wilson, Ira B; Sabin, Lora

    2015-11-01

    Adherence to antiretroviral medications is usually expressed in terms of the proportion of doses taken. However, the timing of doses taken may also be an important dimension to overall adherence. Little is known about whether patients who mistime doses are also more likely to skip doses. Using data from the completed Adherence for Life randomized controlled trial, we created visual and statistical models to capture and analyze dose timing data collected longitudinally with electronic drug monitors (EDM). From scatter plots depicting dose time versus calendar date, we identified dominant patterns of dose taking and calculated key features [slope of line over calendar date; residual mean standard error (RMSE)]. Each was assessed for its ability to categorize subjects with 'sub-optimal' (<95 % of doses taken) using area under the receiver operating characteristic (AROC) curve analysis. Sixty eight subjects contributed EDM data, with ~300 to 400 observations/subject. While regression line slopes did not predict 'sub-optimal' adherence (AROC 0.51, 95 % CI 0.26-0.75), the variability in dose timing (RMSE) was strongly predictive (AROC 0.79, 95 % CI 0.62-0.97). Compared with the lowest quartile of RMSE (minimal dose time variability), each successive quartile roughly doubled the odds of 'sub-optimal' adherence (OR 2.1, 95 % CI 1.3-3.4). Patterns of dose timing and mistiming are strongly related to overall adherence behavior. Notably, individuals who skip doses are more likely to mistime doses, with the degree of risk positively correlated with the extent of dose timing variability.

  7. Is there a role for pharmacokinetic/pharmacodynamic-guided dosing for novel oral anticoagulants?

    PubMed

    Chan, Noel; Sager, Philip T; Lawrence, Jack; Ortel, Thomas's; Reilly, Paul; Berkowitz, Scott; Kubitza, Dagmar; Eikelboom, John; Florian, Jeffry; Stockbridge, Norman; Rose, Martin; Temple, Robert; Seltzer, Jonathan H

    2018-05-01

    The novel direct oral anticoagulants (NOACs) represent a major advance in oral anticoagulant therapy and are replacing vitamin K antagonists as the preferred options for many indications. Given in fixed doses without routine laboratory monitoring, they have been shown to be at least as effective in reducing thromboembolic stroke as dose-adjusted warfarin in phase 3 randomized trials and less likely to cause hemorrhagic stroke. Pharmacokinetic and/or pharmacodynamic subanalyses of the major NOAC trials in patients with atrial fibrillation have established relationships between clinical characteristics, and drug levels and/or pharmacodynamic responses with both efficacy and safety. Based on these analyses, pharmaceutical manufacturers and regulatory authorities have provided contraindications and dosing recommendations based on clinical characteristics that are associated with drug levels and/or pharmacodynamic responses, stroke reduction, and bleeding risk to optimize the risk-benefit profile of the NOACs in the real world. The current fixed-dosing strategy of NOACs has triggered discussions about the potential value of laboratory monitoring and dose adjustment in customizing drug exposure to further improve the safety and efficacy of the NOACs in patients with atrial fibrillation. As there is neither high-quality evidence nor consensus about the potential role of laboratory monitoring and dose adjustment for the NOACs, a Cardiac Research Safety Consortium "Think Tank" meeting was held at the American College of Cardiology Heart House in December 2015 to discussions these issues. This manuscript reports on the deliberations and the conclusions reached at that meeting. Copyright © 2017. Published by Elsevier Inc.

  8. Evaluation of a LiF:Mg,Ti thermoluminescent ring dosimeter according to the IEC 62387:2012 Standards

    NASA Astrophysics Data System (ADS)

    Oliveira, Edyelle L. B.; de Barros, Vinícius S. M.; Asfora, Viviane K.; Khoury, Helen J.

    2018-03-01

    This work shows results of type testing of a ring radiation dosimeter system under IEC 62387:2012. The personal dosimeter investigated in this work consists of a commercial one element plastic ring which contains an LiF:Mg,Ti thermoluminescent pellet. By applying requirements for statistical fluctuations and linearity, a minimum measurable dose in Hp(0.07) was established. Energy and angular dependence aided in determining energy correction factors and fading requirements were used to select the most appropriate preheat scheme. Type testing of passive radiation monitors was performed in the Radiation Metrology Laboratory (LMRI-DEN/UFPE) of the Federal University of Pernambuco and is a major step in Brazil for the independent evaluation of these dosimeters, currently not available in the country.

  9. UK guidance on the management of personal dosimetry systems for healthcare staff working at multiple organizations.

    PubMed

    Rogers, Andy; Chapple, Claire-Louise; Murray, Maria; Platton, David; Saunderson, John

    2017-11-01

    There has been concern expressed by the UK regulator, the Health & Safety Executive, regarding the management of occupation dose for healthcare radiation workers who work across multiple organizations. In response to this concern, the British Institute of Radiology led a working group of relevant professional bodies to develop guidance in this area. The guidance addresses issues of general system management that would apply to all personal dosimetry systems, regardless of whether or not the workers within that system work across organizational boundaries, along with exploring efficient strategies to comply with legislation where those workers do indeed work across organizational boundaries. For those specific instances, the guidance discusses both system requirements to enable organizations to co-operate (Ionising Radiation Regulations 1999 Regulation 15), as well as specific instances of staff exposure. This is broken down into three categories-low, medium and high risk. A suggested approach to each is given to guide employers and their radiation advisers in adopting sensible strategies for the monitoring of their staff and the subsequent sharing of dosimetry data to ensure overall compliance with both dose limits and optimization requirements.

  10. WWW.NMDB.EU: The real-time Neutron Monitor database

    NASA Astrophysics Data System (ADS)

    Klein, Karl-Ludwig; Steigies, Christian T.; NMDB Consortium

    2010-05-01

    The Real time database for high-resolution neutron monitor measurements (NMDB), which was supported by the 7th framework program of the European Commission, hosts data on cosmic rays in the GeV range from European and some non-European neutron monitor stations. It offers a variety of applications ranging from the representation and retrieval of cosmic ray data over solar energetic particle alerts to the calculation of ionisation doses in the atmosphere and radiation dose rates at aircraft altitudes. Furthermore the web site comprises public outreach pages in several languages and offers training material on cosmic rays for university students and researchers and engineers who want to get familiar with cosmic rays and neutron monitor measurements. This contribution presents an overview of the provided services and indications on how to access the database. Operators of other neutron monitor stations are welcome to submit their data to NMDB.

  11. Calibration of a proton beam energy monitor.

    PubMed

    Moyers, M F; Coutrakon, G B; Ghebremedhin, A; Shahnazi, K; Koss, P; Sanders, E

    2007-06-01

    Delivery of therapeutic proton beams requires an absolute energy accuracy of +/-0.64 to 0.27 MeV for patch fields and a relative energy accuracy of +/-0.10 to 0.25 MeV for tailoring the depth dose distribution using the energy stacking technique. Achromatic switchyard tunes, which lead to better stability of the beam incident onto the patient, unfortunately limit the ability of switchyard magnet tesla meters to verify the correct beam energy within the tolerances listed above. A new monitor to measure the proton energy before each pulse is transported through the switchyard has been installed into a proton synchrotron. The purpose of this monitor is to correct and/or inhibit beam delivery when the measured beam energy is outside of the tolerances for treatment. The monitor calculates the beam energy using data from two frequency and eight beam position monitors that measure the revolution frequency of the proton bunches and the effective offset of the orbit from the nominal radius of the synchrotron. The new energy monitor has been calibrated by measuring the range of the beam through water and comparing with published range-energy tables for various energies. A relationship between depth dose curves and range-energy tables was first determined using Monte Carlo simulations of particle transport and energy deposition. To reduce the uncertainties associated with typical scanning water phantoms, a new technique was devised in which the beam energy was scanned while fixed thickness water tanks were sandwiched between two fixed parallel plate ionization chambers. Using a multitude of tank sizes, several energies were tested to determine the nominal accelerator orbit radius. After calibration, the energy reported by the control system matched the energy derived by range measurements to better than 0.72 MeV for all nine energies tested between 40 and 255 MeV with an average difference of -0.33 MeV. A study of different combinations of revolution frequency and radial offsets to test the envelope of algorithm accuracy demonstrated a relative accuracy of +/-0.11 MeV for small energy changes between 126 and 250 MeV. These new measurements may serve as a data set for benchmarking range-energy relationships.

  12. Glycosylation Profiling of Therapeutic Antibodies in Serum Samples Using a Microfluidic CD Platform and MALDI-MS

    NASA Astrophysics Data System (ADS)

    Thuy, Tran Thi; Thorsén, Gunnar

    2013-07-01

    The serum clearance rate of therapeutic antibodies is important as it affects the clinical efficacy, required dose, and dose frequency. The glycosylation of antibodies has in some studies been shown to have an impact on the elimination rates in vivo. Monitoring changes to the glycan profiles in pharmacokinetics studies can reveal whether the clearance rates of the therapeutic antibodies depend on the different glycoforms, thereby providing useful information for improvement of the drugs. In this paper, a novel method for glycosylation analysis of therapeutic antibodies in serum samples is presented. A microfluidic compact-disc (CD) platform in combination with MALDI-MS was used to monitor changes to the glycosylation profiles of samples incubated in vitro. Antibodies were selectively purified from serum using immunoaffinity capture on immobilized target antigens. The glycans were enzymatically released, purified, and finally analyzed by MALDI-TOF-MS. To simulate changes to glycan profiles after administration in vivo, a therapeutic antibody was incubated in serum with the enzyme α1-2,3 mannosidase to artificially reduce the amount of the high mannose glycoforms. Glycan profiles were monitored at specific intervals during the incubation. The relative abundance of the high mannose 5 glycoform was clearly found to decrease and, simultaneously, that of high mannose 4 increased over the incubation period. The method can be performed in a rapid, parallel, and automated fashion for glycosylation profiling consuming low amounts of samples and reagents. This can contribute to less labor work and reduced cost of the studies of therapeutic antibodies glycosylation in vitro and in vivo.

  13. Considerations for long-term anticoagulant therapy in patients with venous thromboembolism in the novel oral anticoagulant era.

    PubMed

    Toth, Peter P

    2016-01-01

    Patients who have had a venous thromboembolic event are generally advised to receive anticoagulant treatment for 3 months or longer to prevent a recurrent episode. Current guidelines recommend initial heparin and an oral vitamin K antagonist (VKA) for long-term anticoagulation. However, because of the well-described disadvantages of VKAs, including extensive food and drug interactions and the need for regular anticoagulation monitoring, novel oral anticoagulants (NOACs) have become an attractive option in recent years. These agents are given at fixed doses and do not require routine coagulation-time monitoring. The NOACs are discussed in this review with regard to the needs of patients on long-term anticoagulation. Current guidelines from Europe and North America that refer to the treatment of deep vein thrombosis and/or pulmonary embolism are included, as well as published randomized Phase III clinical trials of NOACs. PubMed searches were used for sourcing case studies of long-term anticoagulant treatment, and results were filtered for human application and screened for relevance. NOAC-based therapy showed a similar efficacy and safety profile to heparins/VKAs but without the need for regular anticoagulation monitoring or dietary adjustments, and can be taken as a fixed-dose regimen once or twice daily. This represents a significant step forward in facilitating the management of long-term anticoagulation therapy. Furthermore, in the EINSTEIN studies, improved patient satisfaction was documented with the NOAC rivaroxaban, which may result in better adherence to therapy and an overall reduction in the incidence of recurrent venous thromboembolism.

  14. UV254 absorbance as real-time monitoring and control parameter for micropollutant removal in advanced wastewater treatment with powdered activated carbon.

    PubMed

    Altmann, Johannes; Massa, Lukas; Sperlich, Alexander; Gnirss, Regina; Jekel, Martin

    2016-05-01

    This study investigates the applicability of UV absorbance measurements at 254 nm (UVA254) to serve as a simple and reliable surrogate parameter to monitor and control the removal of organic micropollutants (OMPs) in advanced wastewater treatment applying powdered activated carbon (PAC). Correlations between OMP removal and corresponding UVA254 reduction were determined in lab-scale adsorption batch tests and successfully applied to a pilot-scale PAC treatment stage to predict OMP removals in aggregate samples with good accuracy. Real-time UVA254 measurements were utilized to evaluate adapted PAC dosing strategies and proved to be effective for online monitoring of OMP removal. Furthermore, active PAC dosing control according to differential UVA254 measurements was implemented and tested. While precise removal predictions based on real-time measurements were not accurate for all OMPs, UVA254-controlled dynamic PAC dosing was capable of achieving stable OMP removals. UVA254 can serve as an effective surrogate parameter for OMP removal in technical PAC applications. Even though the applicability as control parameter to adjust PAC dosing to water quality changes might be limited to applications with fast response between PAC adjustment and adsorptive removal (e.g. direct filtration), UVA254 measurements can also be used to monitor the adsorption efficiency in more complex PAC applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Performance evaluation of a LYSO-based PET scanner for monitoring of dose delivery in hadrontherapy

    NASA Astrophysics Data System (ADS)

    Fabbiani, E.; Belcari, N.; Camarlinghi, N.; Del Guerra, A.; Ferretti, S.; Kraan, A.; Panetta, D.; Sportelli, G.; Rosso, V.

    2015-12-01

    The DoPET scanner is a compact positron emission tomography (PET) device. It has been developed for monitoring the range of charged particles during therapy with hadron beams. Previous works have focused on the development and upgrade of the device and on data analysis. In this paper, a full performance characterization of the DoPET system in terms of the energy resolution, spatial resolution, sensitivity, uniformity, and noise equivalent count rate is reported. All measurements refer to an adapted version of the National Electrical Manufacturers Association (NEMA) NU 4 - 2008 protocol, which was written originally for small animal PET systems. Since DoPET is a dual head planar system, it requires a modified characterisation procedure with respect to those described for ring geometries as in the NEMA NU 4 - 2008 protocol. The presented procedure may be of interest for any other PET system with a similar geometry as DoPET.

  16. A biosensor for cadmium based on bioconvective patterns

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Matsos, Helen C.

    1990-01-01

    An 'in vitro' method for monitoring cadmium, one of the most lethal bivalent heavy metals, can detect biologically active levels. The effects of cadmium tend to concentrate in protozoa far above natural levels and therein begin transferring through freshwater food chains to animals and humans. In a small sample volume (approximately 5 ml) the method uses the toxic response to the protozoa, Tetrahymena pyriformis, to cadmium. The assay relies on macroscopic bioconvective patterns to measure the toxic response, giving a sensitivity better than 1 micro-g/1 and a toxicity threshold to 7 micro-g/1 for Cd(2+). Cadmium hinders pattern formation in a dose-dependent manner. Arrested organism growth arises from slowed division and mutation to non-dividing classes. Unlike previous efforts, this method can be performed in a shallow flow device and does not require electronic or chemical analyses to monitor toxicity.

  17. Usefulness of simultaneous and sequential monitoring of glucose level and electrocardiogram in monkeys treated with gatifloxacin under conscious and nonrestricted conditions.

    PubMed

    Yoshimatsu, Yu; Ishizaka, Tomomichi; Chiba, Katsuyoshi; Mori, Kazuhiko

    2018-05-10

    Drug-induced cardiac electrophysiological abnormalities accompanied by hypoglycemia or hyperglycemia increase the risk for life-threatening arrhythmia. To assess the drug-induced cardiotoxic potential associated with extraordinary blood glucose (GLU) levels, the effect of gatifloxacin (GFLX) which was frequently associated with GLU abnormality and QT/QTc prolongations in the clinic on blood GLU and electrocardiogram (ECG) parameters was investigated in cynomolgus monkeys (n=4) given GFLX orally in an ascending dose regimen (10, 30, 60 and 100 mg/kg). Simultaneous and sequential GLU and ECG monitoring with a continuous GLU monitoring system and Holter ECG, respectively, were conducted for 24 h under free-moving conditions. Consequently, GFLX at 30 and 60 mg/kg dose-dependently induced a transient decrease in GLU without any ECG abnormality 2-4 h postdose. Highest dose of 100 mg/kg caused severe hypoglycemia with a mean GLU of <30 mg/dL, accompanied by remarkable QT/QTc prolongations by 20-30% in all animals. In contrast, hyperglycemia without QT/QTc prolongations was noted 24 h after dosing in one animal. A close correlation between GLU and QTc values was observed in animals treated with 100 mg/kg, suggesting that GFLX-induced hypoglycemia enhanced QT/QTc prolongations. Furthermore, the 24-h sequential GLU monitoring data clearly distinguished between GFLX-induced GLU abnormality and physiological GLU changes influenced by feeding throughout the day. In conclusion, the combined assessment of continuous GLU and ECG monitoring is valuable in predicting the drug-induced cardio-electrophysiological risk associated with both GLU and ECG abnormalities.

  18. The frequency of Pig-a mutant red blood cells in rats exposed in utero to N-ethyl-N-nitrosourea.

    PubMed

    Dobrovolsky, Vasily N; Heflich, Robert H; Ferguson, Sherry A

    2012-07-01

    The Pig-a assay has been developed as a rapid sensitive measure of gene mutation in adult rats; however, no data exist on its ability to detect mutation following in utero exposures or in neonatal animals. Pregnant Sprague-Dawley rats were treated daily on gestational days 12-18 with oral doses of 0, 6, or 12 mg/kg/day N-ethyl-N-nitrosourea (ENU); following parturition, the offspring and dams were monitored over a period of 5 months for the frequency of CD59-deficient erythrocytes as a marker of Pig-a mutation. Significant dose-related increases in Pig-a mutant red blood cells (RBCs) were observed in ENU-treated dams. However, only very weak increases in RBC Pig-a mutant frequency (MF) were noted in offspring treated in utero with the lower ENU dose. The higher ENU dose produced extremely variable responses in the offspring as a function of age, even among littermates, ranging from a steady low or moderately high Pig-a MF to a rapidly increasing or decreasing Pig-a MF. The manifestation kinetics of Pig-a mutant RBCs in the offspring suggest that the change from predominantly hepatic to predominantly bone marrow erythropoiesis that occurs during early development may have contributed to this variability. Our results indicate that using the RBC Pig-a model for mutation detection in animals treated in utero may require analysis of multiple offspring from the same litter to account for potential "jack pot" effects, and that detection of the earliest treatment effect (i.e., in neonates using the hepatic RBC fraction) may require optimization of blood processing. Published 2012 Wiley Periodicals, Inc.

  19. Hanford Environmental Dose Reconstruction Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cannon, S.D.; Finch, S.M.

    1992-10-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates):Source Terms, Environmental Transport, Environmental Monitoring Data, Demography, Food Consumption, and Agriculture, and Environmental Pathways and Dose Estimates.

  20. Estimation of annual occupational effective doses from external ionizing radiation at medical institutions in Kenya

    NASA Astrophysics Data System (ADS)

    Korir, Geoffrey; Wambani, Jeska; Korir, Ian

    2011-04-01

    This study details the distribution and trends of doses due to occupational radiation exposure among radiation workers from participating medical institutions in Kenya, where monthly dose measurements were collected for a period of one year ranging from January to December in 2007. A total of 367 medical radiation workers were monitored using thermoluminescent dosemeters. They included radiologists (27%), oncologists (2%), dentists (4%), Physicists (5%), technologists (45%), nurses (4%), film processor technicians (3%), auxiliary staff (4%), and radiology office staff (5%). The average annual effective dose of all categories of staff was found to range from 1.19 to 2.52 mSv. This study formed the initiation stage of wider, comprehensive and more frequent monitoring of occupational radiation exposures and long-term investigations into its accumulation patterns in our country.

Top