Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Idaho
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Idaho. Moving to the 2015 IECC from the 2015 Idaho State Code base code is cost-effective for residential buildings in all climate zones in Idaho.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Montana
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Montana. Moving to the 2015 IECC from the 2014 Montana State Code base code is cost-effective for residential buildings in all climate zones in Montana.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Iowa
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Iowa. Moving to the 2015 IECC from the 2014 Iowa State Code base code is cost-effective for residential buildings in all climate zones in Iowa.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Utah
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Utah. Moving to the 2015 IECC from the 2012 Utah State Code base code is cost-effective for residential buildings in all climate zones in Utah.
Residential Building Energy Code Field Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Bartlett, M. Halverson, V. Mendon, J. Hathaway, Y. Xie
This document presents a methodology for assessing baseline energy efficiency in new single-family residential buildings and quantifying related savings potential. The approach was developed by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) Building Energy Codes Program with the objective of assisting states as they assess energy efficiency in residential buildings and implementation of their building energy codes, as well as to target areas for improvement through energy codes and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data setmore » to represent baseline construction practices across U.S. states.« less
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for New Hampshire
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in New Hampshire. Moving to the 2015 IECC from the 2010 New Hampshire State Code base code is cost-effective for residential buildings in all climate zones in New Hampshire.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for North Carolina
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in North Carolina. Moving to the 2015 IECC from the 2012 North Carolina State Code base code is cost-effective for residential buildings in all climate zones in North Carolina.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in the District of Columbia. Moving to the 2015 IECC from the 2013 Washington DC Code base code is cost-effective for residential buildings in all climate zones in the District of Columbia.
76 FR 64924 - Updating State Residential Building Energy Efficiency Codes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-19
...) considers high-rise (greater than three stories) multifamily residential buildings and hotel, motel, and..., duplexes, townhouses, row houses, and low-rise multifamily buildings (not greater than three stories) such... pumps as compared to other electric heating technologies, this code change is expected to increase the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vine, E.
1990-11-01
As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing to construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. 12 refs., 5 tabs.« less
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Arkansas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Arkansas. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Arkansas.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Texas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Texas. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Texas.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Minnesota
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Minnesota. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Minnesota.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Indiana
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Indiana. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Indiana.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Oklahoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Oklahoma. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Oklahoma.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Florida
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Florida. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Florida.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Maine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Maine. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Maine.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Vermont
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Vermont. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Vermont.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Louisiana
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Louisiana. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Louisiana.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Alabama
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Alabama. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Alabama.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Colorado
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Colorado. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Colorado.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Michigan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Michigan. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Michigan.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Maryland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Maryland. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Maryland.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Pennsylvania
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Pennsylvania. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Pennsylvania.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Massachusetts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Massachusetts. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Massachusetts.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Wisconsin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Wisconsin. Moving to the 2015 IECC from the 2006 IECC base code is cost-effective for residential buildings in all climate zones in Wisconsin.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Ohio
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in Ohio. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Ohio.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Illinois
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Illinois. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Illinois.
76 FR 42688 - Updating State Residential Building Energy Efficiency Codes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... 19, 2013. ADDRESSES: Certification Statements must be addressed to the Buildings Technologies Program...-rise (greater than three stories) multifamily residential buildings and hotel, motel, and other..., townhouses, row houses, and low-rise multifamily buildings (not greater than three stories) such as...
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Rhode Island
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Rhode Island. Moving to the 2015 IECC from the 2012 IECC base code is cost-effective for residential buildings in all climate zones in Rhode Island.
Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for South Carolina
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
2016-02-15
The 2015 IECC provides cost-effective savings for residential buildings in South Carolina. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in South Carolina.
24 CFR 578.75 - General operations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... assistance under this part must meet State or local building codes, and in the absence of State or local building codes, the International Residential Code or International Building Code (as applicable to the type of structure) of the International Code Council. (2) Services provided with assistance under this...
24 CFR 578.75 - General operations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... assistance under this part must meet State or local building codes, and in the absence of State or local building codes, the International Residential Code or International Building Code (as applicable to the type of structure) of the International Code Council. (2) Services provided with assistance under this...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Arizona. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Arizona.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Hawaii. Moving to the 2015 IECC from the 2006 IECC base code is cost-effective for residential buildings in all climate zones in Hawaii.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in Connecticut. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in Connecticut.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in New York. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in New York.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.
The 2015 IECC provides cost-effective savings for residential buildings in New Mexico. Moving to the 2015 IECC from the 2009 IECC base code is cost-effective for residential buildings in all climate zones in New Mexico.
Potential Job Creation in Rhode Island as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Potential Job Creation in Minnesota as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Potential Job Creation in Tennessee as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Potential Job Creation in Nevada as a Result of Adopting New Residential Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Michael J.; Niemeyer, Jackie M.
Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
... for Residential Construction in High Wind Regions. ICC 700: National Green Building Standard The..., coordinated, and necessary to regulate the built environment. Federal agencies frequently use these codes and... International Codes and Standards consist of the following: ICC Codes International Building Code. International...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-16
... for Residential Construction in High Wind Areas. ICC 700: National Green Building Standard. The... Codes and Standards that are comprehensive, coordinated, and necessary to regulate the built environment... International Codes and Standards consist of the following: ICC Codes International Building Code. International...
Country Report on Building Energy Codes in Australia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shui, Bin; Evans, Meredydd; Somasundaram, Sriram
2009-04-02
This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Australia, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Australia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vine, E.
1990-11-01
As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. Because statewide codes are enforced by local officials, these problems may increase over time as energy standards change and become more complex and as other standards (eg, health and safety codes) remain a higher priority. The California Energy Commission realizes that code enforcement by itself is insufficient and expects that additional educational and technical assistance efforts (eg, manuals, training programs, and toll-free telephone lines) will ameliorate these problems.« less
Residential photovoltaic module and array requirements study
NASA Technical Reports Server (NTRS)
Nearhoof, S. L.; Oster, J. R.
1979-01-01
Design requirements for photovoltaic modules and arrays used in residential applications were identified. Building codes and referenced standards were reviewed for their applicability to residential photovoltaic array installations. Four installation types were identified - integral (replaces roofing), direct (mounted on top of roofing), stand-off (mounted away from roofing), and rack (for flat or low slope roofs, or ground mounted). Installation costs were developed for these mounting types as a function of panel/module size. Studies were performed to identify optimum module shapes and sizes and operating voltage cost drivers. It is concluded that there are no perceived major obstacles to the use of photovoltaic modules in residential arrays. However, there is no applicable building code category for residential photovoltaic modules and arrays and additional work with standards writing organizations is needed to develop residential module and array requirements.
Country Report on Building Energy Codes in Canada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shui, Bin; Evans, Meredydd
2009-04-06
This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America . This reports gives an overview of the development of building energy codes in Canada, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, lighting, and water heating) for commercial and residential buildingsmore » in Canada.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Scope. 434.101 Section 434.101 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL... to new Federal multi-family high rise residential buildings and new Federal commercial buildings, for...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The ARES (Automated Residential Energy Standard) User`s Guide is designed to the user successfully operate the ARES computer program. This guide assumes that the user is familiar with basic PC skills such as using a keyboard and loading a disk drive. The ARES computer program was designed to assist building code officials in creating a residential energy standard based on local climate and costs.
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE... Proposed Design or for calculation of Design Energy Cost. 512.2Internal loads for multi-family high-rise residential buildings are prescribed in Tables 512.2.a and b, Multi-Family High Rise Residential Building...
Compliance Verification Paths for Residential and Commercial Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conover, David R.; Makela, Eric J.; Fannin, Jerica D.
2011-10-10
This report looks at different ways to verify energy code compliance and to ensure that the energy efficiency goals of an adopted document are achieved. Conformity assessment is the body of work that ensures compliance, including activities that can ensure residential and commercial buildings satisfy energy codes and standards. This report identifies and discusses conformity-assessment activities and provides guidance for conducting assessments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendon, Vrushali V.; Taylor, Zachary T.
ABSTRACT: Recent advances in residential building energy efficiency and codes have resulted in increased interest in detailed residential building energy models using the latest energy simulation software. One of the challenges of developing residential building models to characterize new residential building stock is to allow for flexibility to address variability in house features like geometry, configuration, HVAC systems etc. Researchers solved this problem in a novel way by creating a simulation structure capable of creating fully-functional EnergyPlus batch runs using a completely scalable residential EnergyPlus template system. This system was used to create a set of thirty-two residential prototype buildingmore » models covering single- and multifamily buildings, four common foundation types and four common heating system types found in the United States (US). A weighting scheme with detailed state-wise and national weighting factors was designed to supplement the residential prototype models. The complete set is designed to represent a majority of new residential construction stock. The entire structure consists of a system of utility programs developed around the core EnergyPlus simulation engine to automate the creation and management of large-scale simulation studies with minimal human effort. The simulation structure and the residential prototype building models have been used for numerous large-scale studies, one of which is briefly discussed in this paper.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Tan, Qing; Evans, Meredydd
India is expected to add 40 billion m2 of new buildings till 2050. Buildings are responsible for one third of India’s total energy consumption today and building energy use is expected to continue growing driven by rapid income and population growth. The implementation of the Energy Conservation Building Code (ECBC) is one of the measures to improve building energy efficiency. Using the Global Change Assessment Model, this study assesses growth in the buildings sector and impacts of building energy policies in Gujarat, which would help the state adopt ECBC and expand building energy efficiency programs. Without building energy policies, buildingmore » energy use in Gujarat would grow by 15 times in commercial buildings and 4 times in urban residential buildings between 2010 and 2050. ECBC improves energy efficiency in commercial buildings and could reduce building electricity use in Gujarat by 20% in 2050, compared to the no policy scenario. Having energy codes for both commercial and residential buildings could result in additional 10% savings in electricity use. To achieve these intended savings, it is critical to build capacity and institution for robust code implementation.« less
NASA Astrophysics Data System (ADS)
Nahhas, Tariq M.
2011-03-01
This paper presents a comparison of the seismic forces generated from a Modal Response Spectrum Analysis (MRSA) by applying the provisions of two building codes, the 1997 Uniform Building Code (UBC) and the 2000-2009 International Building Code (IBC), to the most common ordinary residential buildings of standard occupancy. Considering IBC as the state of the art benchmark code, the primary concern is the safety of buildings designed using the UBC as compared to those designed using the IBC. A sample of four buildings with different layouts and heights was used for this comparison. Each of these buildings was assumed to be located at four different geographical sample locations arbitrarily selected to represent various earthquake zones on a seismic map of the USA, and was subjected to code-compliant response spectrum analyses for all sample locations and for five different soil types at each location. Response spectrum analysis was performed using the ETABS software package. For all the cases investigated, the UBC was found to be significantly more conservative than the IBC. The UBC design response spectra have higher spectral accelerations, and as a result, the response spectrum analysis provided a much higher base shear and moment in the structural members as compared to the IBC. The conclusion is that ordinary office and residential buildings designed using UBC 1997 are considered to be overdesigned, and therefore they are quite safe even according to the IBC provisions.
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.503 - Prototype building procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper willmore » describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.« less
National Cost-effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, Brian; Halverson, Mark A.; Myer, Michael
Pacific Northwest National Laboratory (PNNL) completed this project for the U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP). DOE’s BECP supports upgrading building energy codes and standards, and the states’ adoption, implementation, and enforcement of upgraded codes and standards. Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. Continuous improvement of building energy efficiency is achieved by periodically upgrading energy codes and standards. Ensuring that changes in the code that may alter costs (for building components,more » initial purchase and installation, replacement, maintenance and energy) are cost-effective encourages their acceptance and implementation. ANSI/ASHRAE/IESNA Standard 90.1 is the energy standard for commercial and multi-family residential buildings over three floors.« less
Cost-effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, Brian A.; Halverson, Mark A.; Myer, Michael
Pacific Northwest National Laboratory (PNNL) completed this project for the U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP). DOE’s BECP supports upgrading building energy codes and standards, and the states’ adoption, implementation, and enforcement of upgraded codes and standards. Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. Continuous improvement of building energy efficiency is achieved by periodically upgrading energy codes and standards. Ensuring that changes in the code that may alter costs (for building components,more » initial purchase and installation, replacement, maintenance and energy) are cost-effective encourages their acceptance and implementation. ANSI/ASHRAE/IESNA Standard 90.1 is the energy standard for commercial and multi-family residential buildings over three floors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vine, E.
Based on an evaluation of 10 residential new construction programs, primarily sponsored by investor-owned utilities in the United States, we find that many of these programs are in dire straits and are in danger of being discontinued because current inclusion of only direct program effects leads to the conclusion that they are not cost-effective. We believe that the cost-effectiveness of residential new construction programs can be improved by: (1) promoting technologies and advanced building design practices that significantly exceed state and federal standards; (2) reducing program marketing costs and developing more effective marketing strategies; (3) recognizing the role of thesemore » programs in increasing compliance with existing state building codes; and (4) allowing utilities to obtain an ``energy-savings credit`` from utility regulators for program spillover (market transformation) impacts. Utilities can also leverage their resources in seizing these opportunities by forming strong and trusting partnerships with the building community and with local and state government.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Purpose. 434.100 Section 434.100 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL... rise residential buildings, for which design for construction began before January 3, 2007. The...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Purpose. 434.100 Section 434.100 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL... rise residential buildings, for which design for construction began before January 3, 2007. The...
Technology change and energy consumption: A comparison of residential subdivisions
NASA Astrophysics Data System (ADS)
Nieves, L. A.; Nieves, A. L.
The energy savings in residential buildings likely to result from implementation of the building energy performance standards (BEPS) were assessed. The goals were to: compare energy use in new homes designed to meet or exceed BEPS levels of energy efficiency with that in similar but older homes designed to meet conventional building codes, and to survey the home owners regarding their energy conservation attitudes and behaviors and to ascertain the degree to which conservation attitudes and behaviors are related to residential energy use. The consumer demand theory which provides the framework for the empirical analysis is presented. The sample residences are described and the data collection method discussed. The definition and measurement of major variables are presented.
Energy Cost Impact of Non-Residential Energy Code Requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jian; Hart, Philip R.; Rosenberg, Michael I.
2016-08-22
The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of themore » probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.« less
10 CFR 434.99 - Explanation of numbering system for codes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...
10 CFR 434.99 - Explanation of numbering system for codes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2014 CFR
2014-04-01
...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2012 CFR
2012-04-01
...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2013 CFR
2013-04-01
...); (6) Individual unit smoke detectors; (7) Building alarm systems; (8) Highrise criteria; (b) Light and...) Design live loads; (2) Design dead loads; (3) Snow loads; (4) Wind loads. (5) Earthquake loads (in...
Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jian; Xie, YuLong; Athalye, Rahul A.
As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildingsmore » constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.« less
Chapter 8: Fire Performance of Cross-Laminated Timber Assemblies (2012 US Edition)
Christian Dagenais; Robert H. White; Kuma Sumathipala
2012-01-01
Cross-laminated timber (CLT) is a promising wood-based structural component and has potential to provide cost-effective building solutions for residential, commercial and institutional buildings as well as large industrial facilities. Market acceptance of CLT requires that it meets the applicable building code requirements.
A long-term, integrated impact assessment of alternative building energy code scenarios in China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Eom, Jiyong; Evans, Meredydd
2014-04-01
China is the second largest building energy user in the world, ranking first and third in residential and commercial energy consumption. Beginning in the early 1980s, the Chinese government has developed a variety of building energy codes to improve building energy efficiency and reduce total energy demand. This paper studies the impact of building energy codes on energy use and CO2 emissions by using a detailed building energy model that represents four distinct climate zones each with three building types, nested in a long-term integrated assessment framework GCAM. An advanced building stock module, coupled with the building energy model, ismore » developed to reflect the characteristics of future building stock and its interaction with the development of building energy codes in China. This paper also evaluates the impacts of building codes on building energy demand in the presence of economy-wide carbon policy. We find that building energy codes would reduce Chinese building energy use by 13% - 22% depending on building code scenarios, with a similar effect preserved even under the carbon policy. The impact of building energy codes shows regional and sectoral variation due to regionally differentiated responses of heating and cooling services to shell efficiency improvement.« less
P.L. 102-486, "Energy Policy Act" (1992)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2011-12-13
Amends the Energy Conservation and Production Act to set a deadline by which each State must certify to the Secretary of Energy whether its energy efficiency standards with respect to residential and commercial building codes meet or exceed those of the Council of American Building Officials (CABO) Model Energy Code, 1992, and of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers, respectively.
Data on European non-residential buildings.
D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo
2017-10-01
This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.
Kamboj, Sunita; Yu, Charley; Johnson, Robert
2013-05-01
The Derived Concentration Guideline Levels for two building areas previously used in waste processing and storage at Argonne National Laboratory were developed using both probabilistic and deterministic radiological environmental pathway analysis. Four scenarios were considered. The two current uses considered were on-site industrial use and off-site residential use with farming. The two future uses (i.e., after an institutional control period of 100 y) were on-site recreational use and on-site residential use with farming. The RESRAD-OFFSITE code was used for the current-use off-site residential/farming scenario and RESRAD (onsite) was used for the other three scenarios. Contaminants of concern were identified from the past operations conducted in the buildings and the actual characterization done at the site. Derived Concentration Guideline Levels were developed for all four scenarios using deterministic and probabilistic approaches, which include both "peak-of-the-means" and "mean-of-the-peaks" analyses. The future-use on-site residential/farming scenario resulted in the most restrictive Derived Concentration Guideline Levels for most radionuclides.
10 CFR 434.506 - Use of the reference building to determine the energy cost budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Use of the reference building to determine the energy cost budget. 434.506 Section 434.506 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.504 - Use of the prototype building to determine the energy cost budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Use of the prototype building to determine the energy cost budget. 434.504 Section 434.504 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
Kneifel, Joshua; O'Rear, Eric; Webb, David; O'Fallon, Cheyney
2018-02-01
To conduct a more complete analysis of low-energy and net-zero energy buildings that considers both the operating and embodied energy/emissions, members of the building community look to life-cycle assessment (LCA) methods. This paper examines differences in the relative impacts of cost-optimal energy efficiency measure combinations depicting residential buildings up to and beyond net-zero energy consumption on operating and embodied flows using data from the Building Industry Reporting and Design for Sustainability (BIRDS) Low-Energy Residential Database. Results indicate that net-zero performance leads to a large increase in embodied flows (over 40%) that offsets some of the reductions in operational flows, but overall life-cycle flows are still reduced by over 60% relative to the state energy code. Overall, building designs beyond net-zero performance can partially offset embodied flows with negative operational flows by replacing traditional electricity generation with solar production, but would require an additional 8.34 kW (18.54 kW in total) of due south facing solar PV to reach net-zero total life-cycle flows. Such a system would meet over 239% of operational consumption of the most energy efficient design considered in this study and over 116% of a state code-compliant building design in its initial year of operation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-06
... jurisdiction did not already perform its own inspections for new construction, and issue building permits and... expected to be minimal. The increased quality of construction materials and the standardization of building... governments that have adopted building codes to regulate and standardize the construction of residential and...
Residential building codes, affordability, and health protection: a risk-tradeoff approach.
Hammitt, J K; Belsky, E S; Levy, J I; Graham, J D
1999-12-01
Residential building codes intended to promote health and safety may produce unintended countervailing risks by adding to the cost of construction. Higher construction costs increase the price of new homes and may increase health and safety risks through "income" and "stock" effects. The income effect arises because households that purchase a new home have less income remaining for spending on other goods that contribute to health and safety. The stock effect arises because suppression of new-home construction leads to slower replacement of less safe housing units. These countervailing risks are not presently considered in code debates. We demonstrate the feasibility of estimating the approximate magnitude of countervailing risks by combining the income effect with three relatively well understood and significant home-health risks. We estimate that a code change that increases the nationwide cost of constructing and maintaining homes by $150 (0.1% of the average cost to build a single-family home) would induce offsetting risks yielding between 2 and 60 premature fatalities or, including morbidity effects, between 20 and 800 lost quality-adjusted life years (both discounted at 3%) each year the code provision remains in effect. To provide a net health benefit, the code change would need to reduce risk by at least this amount. Future research should refine these estimates, incorporate quantitative uncertainty analysis, and apply a full risk-tradeoff approach to real-world case studies of proposed code changes.
Assessment of Literature Related to Combustion Appliance Venting Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapp, V. H.; Less, B. D.; Singer, B. C.
In many residential building retrofit programs, air tightening to increase energy efficiency is often constrained by safety concerns with naturally vented combustion appliances. Tighter residential buildings more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spill combustion exhaust into the living space. Several measures, such as installation guidelines, vent sizing codes, and combustion safety diagnostics, are in place with the intent to prevent backdrafting and combustion spillage, but the diagnostics conflict and the risk mitigation objective is inconsistent. This literature review summarizes the metrics and diagnostics used to assess combustion safety, documents theirmore » technical basis, and investigates their risk mitigations. It compiles information from the following: codes for combustion appliance venting and installation; standards and guidelines for combustion safety diagnostics; research evaluating combustion safety diagnostics; research investigating wind effects on building depressurization and venting; and software for simulating vent system performance.« less
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131Occupancy schedules are...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131 Occupancy schedules are...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131Occupancy schedules are...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
10 CFR 434.605 - Standard Calculation Procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.513 Occupancy. 5131Occupancy schedules are...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
10 CFR 434.510 - Standard calculation procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1 Receptacle loads and...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.515 Receptacles. 515.1Receptacle loads and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1 Interior Lighting Power...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Lighting. 434.514 Section 434.514 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.514 Lighting. 514.1Interior Lighting Power...
10 CFR 434.606 - Simulation tool.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Simulation tool. 434.606 Section 434.606 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.606 Simulation tool. 606.1 The criteria...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false General. 434.601 Section 434.601 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.601 General. 601.1 This subpart provides an...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false General. 434.601 Section 434.601 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.601 General. 601.1This subpart provides an...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false General. 434.601 Section 434.601 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.601 General. 601.1This subpart provides an...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Compliance. 434.102 Section 434.102 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.102 Compliance. 102.1A covered building must be...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Compliance. 434.604 Section 434.604 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.604 Compliance. 604.1 Compliance with this section is...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Compliance. 434.102 Section 434.102 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.102 Compliance. 102.1A covered building must be...
10 CFR 434.105 - Materials and equipment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Materials and equipment. 434.105 Section 434.105 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.105 Materials and equipment. 105.1Building...
10 CFR 434.507 - Calculation procedure and simulation tool.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Calculation procedure and simulation tool. 434.507 Section 434.507 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.507...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1 The...
10 CFR 434.607 - Life cycle cost analysis criteria.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Life cycle cost analysis criteria. 434.607 Section 434.607 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.607 Life cycle cost...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1 If the Design Energy Cost...
10 CFR 434.518 - Service water heating.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Service water heating. 434.518 Section 434.518 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1The...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1The...
10 CFR 434.607 - Life cycle cost analysis criteria.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Life cycle cost analysis criteria. 434.607 Section 434.607 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.607 Life cycle cost...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1 The systems...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.607 - Life cycle cost analysis criteria.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Life cycle cost analysis criteria. 434.607 Section 434.607 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.607 Life cycle cost...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1The...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.511 Orientation and shape. 511.1The...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.518 - Service water heating.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Service water heating. 434.518 Section 434.518 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.518 Service water heating. 518.1The...
10 CFR 434.512 - Internal loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Internal loads. 434.512 Section 434.512 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.512 Internal loads. 512.1The systems...
10 CFR 434.105 - Materials and equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Materials and equipment. 434.105 Section 434.105 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.105 Materials and equipment. 105.1Building...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.603 - Determination of the design energy use.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the design energy use. 434.603 Section 434.603 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.603...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.602 - Determination of the annual energy budget.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the annual energy budget. 434.602 Section 434.602 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.602...
10 CFR 434.603 - Determination of the design energy use.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the design energy use. 434.603 Section 434.603 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.603...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Compliance. 434.509 Section 434.509 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.509 Compliance. 509.1If the Design Energy Cost...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aldrich, Robb; Butterfield, Karla
With funding from the Building America Program, part of the U.S. Department of Energy Building Technologies Office, the Consortium for Advanced Residential Buildings (CARB) worked with BrightBuilt Home (BBH) to evaluate and optimize building systems. CARB’s work focused on a home built by Black Bros. Builders in Lincolnville, Maine (International Energy Conservation Code Climate Zone 6). As with most BBH projects to date, modular boxes were built by Keiser Homes in Oxford, Maine.
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2010 CFR
2010-04-01
...., materials, allowable stresses, design; (6) Excavation; (e) Materials standards. (f) Construction components...) Plumbing fixtures; (7) Water supply and distribution; (8) Storm drain systems. (j) Electrical. (1) Wiring...
24 CFR 200.925b - Residential and institutional building code comparison items.
Code of Federal Regulations, 2011 CFR
2011-04-01
...., materials, allowable stresses, design; (6) Excavation; (e) Materials standards. (f) Construction components...) Plumbing fixtures; (7) Water supply and distribution; (8) Storm drain systems. (j) Electrical. (1) Wiring...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, Pamala C.; Richman, Eric E.
2008-09-01
Feeling dim from energy code confusion? Read on to give your inspections a charge. The U.S. Department of Energy’s Building Energy Codes Program addresses hundreds of inquiries from the energy codes community every year. This article offers clarification for topics of confusion submitted to BECP Technical Support of interest to electrical inspectors, focusing on the residential and commercial energy code requirements based on the most recently published 2006 International Energy Conservation Code® and ANSI/ASHRAE/IESNA1 Standard 90.1-2004.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lstiburek, Joseph
2017-01-01
The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lstiburek, Joseph
The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less
Residential photovoltaic module and array requirements study, appendices
NASA Technical Reports Server (NTRS)
Nearhoof, S. L.; Oster, J. R.
1979-01-01
Regional building code variations, federal and city codes, and the national electric code are reviewed for their possible effects on the design of photovoltaic modules. Problems that photovoltaic arrays may impose on the insurability of residences are also discussed. Mounting configurations are developed for the modules, and grounding, wiring, terminal, and voltage requirements are established. Installation and materials costs are presented along with performance criteria.
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.508 - Determination of the design energy consumption and design energy cost.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Determination of the design energy consumption and design energy cost. 434.508 Section 434.508 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance...
10 CFR 434.502 - Determination of the annual energy cost budget.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Determination of the annual energy cost budget. 434.502 Section 434.502 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.502...
The performance of adobe and other thermal mass materials in residential buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, D.
1986-01-01
This paper reviews the history and current status of thermal mass research, and national, state, and local codes with respect to thermal mass; and offers specific recommendations on how best to use thermal mass for energy efficiency and comfort. Much of the material comes directly from the Southwest Thermal Mass Study (SWTMS), an experimental research study on the thermal performance of adobe conducted at Tesuque Pueblo, New Mexico, in the early 1980s. The focus is primarily on residential construction, although the theory and most of the recommendations apply to small commercial buildings as well.
Impacts of Model Building Energy Codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Athalye, Rahul A.; Sivaraman, Deepak; Elliott, Douglas B.
The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions atmore » the state level and at aggregated levels. This analysis does not represent all potential savings from energy codes in the U.S. because it excludes several states which have codes which are fundamentally different from the national model energy codes or which do not have state-wide codes. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when buildings comply with the code. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. Delayed adoption of a model code and incomplete compliance with the code’s requirements erode potential savings. The contributions of all three phases are crucial to the overall impact of codes, and are considered in this assessment.« less
Energy analysis of cool, medium, and dark roofs on residential buildings in the U.S
NASA Astrophysics Data System (ADS)
Dunbar, Michael A.
This study reports an energy analysis of cool, medium, and dark roofs on residential buildings in the U.S. Three analyses were undertaken in this study: energy consumption, economic analysis, and an environmental analysis. The energy consumption reports the electricity and natural gas consumption of the simulations. The economic analysis uses tools such as simple payback period (SPP) and net present value (NPV) to determine the profitability of the cool roof and the medium roof. The variable change for each simulation model was the roof color. The default color was a dark roof and the results were focused on the changes produced by the cool roof and the medium roof. The environmental analysis uses CO2 emissions to assess the environmental impact of the cool roof and the medium roof. The analysis uses the U.S. Department of Energy (DOE) EnergyPlus software to produce simulations of a typical, two-story residential home in the U.S. The building details of the typical, two-story U.S. residential home and the International Energy Conservation Code (IECC) building code standards used are discussed in this study. This study indicates that, when material and labor costs are. assessed, the cool roof and the medium roof do not yield a SPP less than 10 years. Furthermore, the NPV results assess that neither the cool roof nor the medium roof are a profitable investment in any climate zone in the U.S. The environmental analysis demonstrates that both the cool roof and the medium roof have a positive impact in warmer climates by reducing the CO2 emissions as much as 264 kg and 129 kg, respectively.
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2013 CFR
2013-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2011 CFR
2011-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2014 CFR
2014-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2012 CFR
2012-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
24 CFR 200.926a - Residential building code comparison items.
Code of Federal Regulations, 2010 CFR
2010-04-01
... doors and windows; (5) Unit smoke detectors; (6) Flame spread. (b) Light and ventilation. (1) Habitable... of ASCE-7-88 (formerly ANSI A58.1-82); (4) Wind loads; (5) Earthquake loads (for jurisdictions in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkler, Jon; Booten, Chuck
Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity.more » The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.« less
Energy Savings Analysis of the Proposed Revision of the Washington D.C. Non-Residential Energy Code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberg, Michael I.; Athalye, Rahul A.; Hart, Philip R.
This report presents the results of an assessment of savings for the proposed Washington D.C. energy code relative to ASHRAE Standard 90.1-2010. It includes annual and life cycle savings for site energy, source energy, energy cost, and carbon dioxide emissions that would result from adoption and enforcement of the proposed code for newly constructed buildings in Washington D.C. over a five year period.
2013 Building Technologies Office Program Peer Review Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2013-11-01
The 2013 Building Technologies Office Program Peer Review Report summarizes the results of the 2013 Building Technologies Office (BTO) peer review, which was held in Washington, D.C., on April 2–4, 2013. The review was attended by over 300 participants and included presentations on 59 BTO-funded projects: 29 from BTO’s Emerging Technologies Program, 20 from the Commercial Buildings Integration Program, 6 from the Residential Buildings Integration Program, and 4 from the Building Energy Codes Program. This report summarizes the scores and comments provided by the independent reviewers for each project.
SIP Shear Walls: Cyclic Performance of High-Aspect-Ratio Segments and Perforated Walls
Vladimir Kochkin; Douglas R. Rammer; Kevin Kauffman; Thomas Wiliamson; Robert J. Ross
2015-01-01
Increasing stringency of energy codes and the growing market demand for more energy efficient buildings gives structural insulated panel (SIP) construction an opportunity to increase its use in commercial and residential buildings. However, shear wall aspect ratio limitations and lack of knowledge on how to design SIPs with window and door openings are barriers to the...
NASA Astrophysics Data System (ADS)
Hartley, M. D.; Jaques, R. E.
1986-11-01
The Canadian Electrical Code and the National Building Code in Canada recognize only two designations in regards to fire resistance of cables; cables for use in combustible (residential) buildings and cables for use in non-combustible buildings. The Test standard for cables for non-combustible buildings resembles IEEE-383. However, it is more severe; particularly for small nonarmoured cables such as Inside Wiring Cable. This forthcoming requirement has necessitated material and product development. Although an Inside Wiring cable modification of both insulation and jacket was undertaken, the large volume fraction of combustible material in the jacket vis a vis the insulation made it the area of greatest impact. The paper outlines the development and its effect on cable performance.
Codes and standards for structural wood products and their use in the United States
David W. Green; Roland Hernandez
1998-01-01
The system of model building codes and voluntary product standards used in the United States for structural lumber and engineered wood products can appear complicated and confusing to those introduced to it for the first time. This paper is a discussion of the various types of structural wood products commonly used in U.S. residential and commercial construction and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... Loan Mortgage Corporation. ICC means International Code Council. IECC means International Energy...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... Loan Mortgage Corporation. ICC means International Code Council. IECC means International Energy...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... Loan Mortgage Corporation. ICC means International Code Council. IECC means International Energy...
Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klocke, S.; Faakye, O.; Puttagunta, S.
2014-10-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Consortium for Advanced Residential Building's (CARB’s) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... International Energy Conservation Code, 2004 Supplement Edition, January 2005 (incorporated by reference, see...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-11-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While thismore » air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.« less
Hester, Nathan; Li, Ke; Schramski, John R; Crittenden, John
2012-04-30
Globally, residential energy consumption continues to rise due to a variety of trends such as increasing access to modern appliances, overall population growth, and the overall increase of electricity distribution. Currently, residential energy consumption accounts for approximately one-fifth of total U.S. energy consumption. This research analyzes the effectiveness of a range of energy-saving measures for residential houses in semi-arid climates. These energy-saving measures include: structural insulated panels (SIP) for exterior wall construction, daylight control, increased window area, efficient window glass suitable for the local weather, and several combinations of these. Our model determined that energy consumption is reduced by up to 6.1% when multiple energy savings technologies are combined. In addition, pre-construction technologies (structural insulated panels (SIPs), daylight control, and increased window area) provide roughly 4 times the energy savings when compared to post-construction technologies (window blinds and efficient window glass). The model also illuminated the importance variations in local climate and building configuration; highlighting the site-specific nature of this type of energy consumption quantification for policy and building code considerations. Published by Elsevier Ltd.
10 CFR 434.103 - Referenced standards (RS).
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Referenced standards (RS). 434.103 Section 434.103 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.103 Referenced standards (RS). 103.1The...
75 FR 54131 - Updating State Residential Building Energy Efficiency Codes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-03
... and 95 degrees F for heating (for heat pumps), the 2000 IECC insulation requirement for supply ducts in unconditioned spaces is R-5 (minimum) for nearly all cases. Insulation required by the 2000 IECC... Duct Insulation Requirements Duct insulation requirements generally increased in the 2003 IECC. The...
10 CFR 434.103 - Referenced standards (RS).
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Referenced standards (RS). 434.103 Section 434.103 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.103 Referenced standards (RS). 103.1The...
10 CFR 434.511 - Orientation and shape.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Orientation and shape. 434.511 Section 434.511 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE... ft. except for dwelling units in hotels/motels and multi-family high-rise residential buildings where...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Springer, David; German, Alea
Building cost-effective, high-performance homes that provide superior comfort, health, and durability is the goal of the U.S. Department of Energy’s (DOE’s) Zero Energy Ready Home (ZERH) program. Building America research and other innovative programs throughout the country have addressed many of the technical challenges of building to the ZERH standard. The cost-effectiveness of measure packages that result in 30% source energy savings compared to a code-compliant home have been demonstrated. However, additional challenges remain, particularly with respect to convincing production builders of the strong business case for ZERH. The Alliance for Residential Building Innovation (ARBI) team believes that the keysmore » to successfully engaging builders and developers in the California market are to help them leverage development agreement requirements, code compliance requirements, incentives, and competitive market advantages of ZERH certification, and navigate through this process. A primary objective of this project was to gain a highly visible foothold for residential buildings that are built to the DOE ZERH specification that can be used to encourage participation by other California builders. This report briefly describes two single-family homes that were ZERH certified and focuses on the experience of working with developer Mutual Housing on a 62-unit multifamily community at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project in the country. This report discusses the challenges encountered, lessons learned, and how obstacles were overcome.« less
Deep influence of passive low energy consumption multi-storey residential building in cold region
NASA Astrophysics Data System (ADS)
Shuai, Zhang; Lihua, Zhao; Rong, Jin; Dong, Junyan
2018-02-01
The example of passive architecture demonstration building in Jilin Province, China, based on the practical experience of this project, the control index of passive and low energy consumption residential buildings in cold and passive buildings is referenced by reference to the German construction standard and the Chinese residence construction document, “passive ultra-low energy consumption green Building Technology Guide (Trial)”. The requirement of passive low energy residential buildings on the ground heat transfer coefficient limits is determined, and the performance requirements of passive residential buildings are discussed. This paper analyzes the requirement of the passive low energy residential building on the ground heat transfer coefficient limit, and probes into the influence factors of the ground thermal insulation of the passive low energy consumption residential building. The construction method of passive low energy consumption residential building is proposed.
Synthetic building materials for transport buildings and structures
NASA Astrophysics Data System (ADS)
Gerasimova, Vera
2017-10-01
The most effective building materials account for the highest growth not only in construction of residential and public buildings, but also other capital projects including roadways, bridges, drainage, communications and other engineering projects. Advancement in the technology of more efficient and ecologically responsible insulation materials have been a priority for safety, minimal maintenance and longevity of finished construction projects. The practical use of modern building materials such as insulation, sound reduction and low energy consumption are a benefit in cost and application compared to the use of outdated heavier and labor-intensive materials. The most efficient way for maximizing insolation and sound proofing should be done during the design stages of the project according to existing codes and regulations that are required by Western Government. All methods and materials that are used need to be optimized in order to reach a high durability and low operational and maintenance cost exceeding more than 50 years of the life of the building, whether it is for public, industrial or residential use. Western construction techniques and technologies need to be applied and adapted by the Russian Federation to insure the most productive successful methods are being implemented. The issues of efficient insulation materials are outlined in this article.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Evans, Meredydd; Shi, Qing
China will account for about half of the new construction globally in the coming decade. Its floorspace doubled from 1996 to 2011, and Chinese rural buildings alone have as much floorspace as all of U.S. residential buildings. Building energy consumption has also grown, increasing by over 40% since 1990. To curb building energy demand, the Chinese government has launched a series of policies and programs. Combined, this growth in buildings and renovations, along with the policies to promote green buildings, are creating a large market for energy efficiency products and services. This report assesses the impact of China’s policies onmore » building energy efficiency and on the market for energy efficiency in the future. The first chapter of this report introduces the trends in China, drawing on both historical analysis, and detailed modeling of the drivers behind changes in floorspace and building energy demand such as economic and population growth, urbanization, policy. The analysis describes the trends by region, building type and energy service. The second chapter discusses China’s policies to promote green buildings. China began developing building energy codes in the 1980s. Over time, the central government has increased the stringency of the code requirements and the extent of enforcement. The codes are mandatory in all new buildings and major renovations in China’s cities, and they have been a driving force behind the expansion of China’s markets for insulation, efficient windows, and other green building materials. China also has several other important policies to encourage efficient buildings, including the Three-Star Rating System (somewhat akin to LEED), financial incentives tied to efficiency, appliance standards, a phasing out of incandescent bulbs and promotion of efficient lighting, and several policies to encourage retrofits in existing buildings. In the third chapter, we take “deep dives” into the trends affecting key building components. This chapter examines insulation in walls and roofs; efficient windows and doors; heating, air conditioning and controls; and lighting. These markets have seen significant growth because of the strength of the construction sector but also the specific policies that require and promote efficient building components. At the same time, as requirements have become more stringent, there has been fierce competition, and quality has at time suffered, which in turn has created additional challenges. Next we examine existing buildings in chapter four. China has many Soviet-style, inefficient buildings built before stringent requirements for efficiency were more widely enforced. As a result, there are several specific market opportunities related to retrofits. These fall into two or three categories. First, China now has a code for retrofitting residential buildings in the north. Local governments have targets of the number of buildings they must retrofit each year, and they help finance the changes. The requirements focus on insulation, windows, and heat distribution. Second, the Chinese government recently decided to increase the scale of its retrofits of government and state-owned buildings. It hopes to achieve large scale changes through energy service contracts, which creates an opportunity for energy service companies. Third, there is also a small but growing trend to apply energy service contracts to large commercial and residential buildings. This report assesses the impacts of China’s policies on building energy efficiency. By examining the existing literature and interviewing stakeholders from the public, academic, and private sectors, the report seeks to offer an in-depth insights of the opportunities and barriers for major market segments related to building energy efficiency. The report also discusses trends in building energy use, policies promoting building energy efficiency, and energy performance contracting for public building retrofits.« less
Microsoft Licenses Berkeley Lab's Home Energy Saver Code for Its Energy
-based tool for calculating energy use in residential buildings. About one million people visit the Home Management Software | Berkeley Lab Berkeley Lab A-Z Index Directory Submit Web People Navigation Berkeley Lab Search Submit Web People Close About the Lab Leadership/Organization Calendar News
Implementing Nepal's national building code—A case study in patience and persistence
Arendt, Lucy; Hortacsu, Ayse; Jaiswal, Kishor; Bevington, John; Shrestha, Surya; Lanning, Forrest; Mentor-William, Garmalia; Naeem, Ghazala; Thibert, Kate
2017-01-01
The April 2015 Gorkha Nepal earthquake revealed the relative effectiveness of the Nepal Standard, or national building code (NBC), and irregular compliance with it in different parts of Nepal. Much of the damage to more than half a million Nepal's residential structures may be attributed to the prevalence of owner-built or owner-supervised construction and the lack of owner and builder responsiveness to seismic risk and training in the appropriate means of complying with the NBC. To explain these circumstances, we review the protracted implementation of the NBC and the role played by one organization, the National Society for Earthquake Technology-Nepal (NSET), in the NBC's implementation. We also share observations on building code compliance made by individuals in Nepal participating in workshops led by the Earthquake Engineering Research Institute's 2014 class of Housner Fellows.
NASA Astrophysics Data System (ADS)
Zhang, Bin; Liu, Yueyan; Zhang, Zuyu; Shen, Yonglin
2017-10-01
A multifeature soft-probability cascading scheme to solve the problem of land use and land cover (LULC) classification using high-spatial-resolution images to map rural residential areas in China is proposed. The proposed method is used to build midlevel LULC features. Local features are frequently considered as low-level feature descriptors in a midlevel feature learning method. However, spectral and textural features, which are very effective low-level features, are neglected. The acquisition of the dictionary of sparse coding is unsupervised, and this phenomenon reduces the discriminative power of the midlevel feature. Thus, we propose to learn supervised features based on sparse coding, a support vector machine (SVM) classifier, and a conditional random field (CRF) model to utilize the different effective low-level features and improve the discriminability of midlevel feature descriptors. First, three kinds of typical low-level features, namely, dense scale-invariant feature transform, gray-level co-occurrence matrix, and spectral features, are extracted separately. Second, combined with sparse coding and the SVM classifier, the probabilities of the different LULC classes are inferred to build supervised feature descriptors. Finally, the CRF model, which consists of two parts: unary potential and pairwise potential, is employed to construct an LULC classification map. Experimental results show that the proposed classification scheme can achieve impressive performance when the total accuracy reached about 87%.
The HayWired earthquake scenario—Engineering implications
Detweiler, Shane T.; Wein, Anne M.
2018-04-18
The HayWired Earthquake Scenario—Engineering Implications is the second volume of U.S. Geological Survey (USGS) Scientific Investigations Report 2017–5013, which describes the HayWired scenario, developed by USGS and its partners. The scenario is a hypothetical yet scientifically realistic earthquake sequence that is being used to better understand hazards for the San Francisco Bay region during and after a magnitude-7 earthquake (mainshock) on the Hayward Fault and its aftershocks.Analyses in this volume suggest that (1) 800 deaths and 16,000 nonfatal injuries result from shaking alone, plus property and direct business interruption losses of more than $82 billion from shaking, liquefaction, and landslides; (2) the building code is designed to protect lives, but even if all buildings in the region complied with current building codes, 0.4 percent could collapse, 5 percent could be unsafe to occupy, and 19 percent could have restricted use; (3) people expect, prefer, and would be willing to pay for greater resilience of buildings; (4) more than 22,000 people could require extrication from stalled elevators, and more than 2,400 people could require rescue from collapsed buildings; (5) the average east-bay resident could lose water service for 6 weeks, some for as long as 6 months; (6) older steel-frame high-rise office buildings and new reinforced-concrete residential buildings in downtown San Francisco and Oakland could be unusable for as long as 10 months; (7) about 450 large fires could result in a loss of residential and commercial building floor area equivalent to more than 52,000 single-family homes and cause property (building and content) losses approaching $30 billion; and (8) combining earthquake early warning (ShakeAlert) with “drop, cover, and hold on” actions could prevent as many as 1,500 nonfatal injuries out of 18,000 total estimated nonfatal injuries from shaking and liquefaction hazards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The country’s first Zero Energy Ready manufactured home that is certified by the U.S. Department of Energy (DOE) is up and running in Russellville, Alabama. The manufactured home was built by a partnership between Southern Energy Homes and the Advanced Residential Integrated Energy Solutions Collaborative (ARIES), which is a DOE Building America team. The effort was part of a three-home study including a standard-code manufactured home and an ENERGY STAR® manufactured home. Cooling-season results showed that the building used half the space-conditioning energy of a manufactured home built to the U.S. Department of Housing and Urban Development’s (HUD’s) Manufactured Homemore » Construction and Safety Standards. These standards are known collectively as the HUD Code, which is the building standard for all U.S. manufactured housing.« less
Impacts: NIST Building and Fire Research Laboratory (technical and societal)
NASA Astrophysics Data System (ADS)
Raufaste, N. J.
1993-08-01
The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.
Development of Maximum Considered Earthquake Ground Motion Maps
Leyendecker, E.V.; Hunt, R.J.; Frankel, A.D.; Rukstales, K.S.
2000-01-01
The 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings use a design procedure that is based on spectral response acceleration rather than the traditional peak ground acceleration, peak ground velocity, or zone factors. The spectral response accelerations are obtained from maps prepared following the recommendations of the Building Seismic Safety Council's (BSSC) Seismic Design Procedures Group (SDPG). The SDPG-recommended maps, the Maximum Considered Earthquake (MCE) Ground Motion Maps, are based on the U.S. Geological Survey (USGS) probabilistic hazard maps with additional modifications incorporating deterministic ground motions in selected areas and the application of engineering judgement. The MCE ground motion maps included with the 1997 NEHRP Provisions also serve as the basis for the ground motion maps used in the seismic design portions of the 2000 International Building Code and the 2000 International Residential Code. Additionally the design maps prepared for the 1997 NEHRP Provisions, combined with selected USGS probabilistic maps, are used with the 1997 NEHRP Guidelines for the Seismic Rehabilitation of Buildings.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... building means a new Federal low-rise residential building that is otherwise identical to the proposed...
Design and optimization of zero-energy-consumption based solar energy residential building systems
NASA Astrophysics Data System (ADS)
Zheng, D. L.; Yu, L. J.; Tan, H. W.
2017-11-01
Energy consumption of residential buildings has grown fast in recent years, thus raising a challenge on zero energy residential building (ZERB) systems, which aim at substantially reducing energy consumption of residential buildings. Thus, how to facilitate ZERB has become a hot but difficult topic. In the paper, we put forward the overall design principle of ZERB based on analysis of the systems’ energy demand. In particular, the architecture for both schematic design and passive technology is optimized and both energy simulation analysis and energy balancing analysis are implemented, followed by committing the selection of high-efficiency appliance and renewable energy sources for ZERB residential building. In addition, Chinese classical residential building has been investigated in the proposed case, in which several critical aspects such as building optimization, passive design, PV panel and HVAC system integrated with solar water heater, Phase change materials, natural ventilation, etc., have been taken into consideration.
77 FR 29322 - Updating State Residential Building Energy Efficiency Codes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
... supporting the change to the SHGC requirements in climate zone 4. Specifically, RECA supported the... to change Climate Zone 3 from R13 to either R20 or R13+5 ci.'' (CFEC, No. 2 at p. 2) In response, DOE... difference of 50 Pascals (5 ACH50) in climate zone 1 and climate zone 2; and 3 air changes/hour (3 ACH50) in...
Updates to building-code maps for the 2015 NEHRP recommended seismic provisions
Luco, Nicolas; Bachman, Robert; Crouse, C.B; Harris, James R.; Hooper, John D.; Kircher, Charles A.; Caldwell, Phillp; Rukstales, Kenneth S.
2015-01-01
With the 2014 update of the U.S. Geological Survey (USGS) National Seismic Hazard Model (NSHM) as a basis, the Building Seismic Safety Council (BSSC) has updated the earthquake ground motion maps in the National Earthquake Hazards Reduction Program (NEHRP) Recommended Seismic Provisions for New Buildings and Other Structures, with partial funding from the Federal Emergency Management Agency. Anticipated adoption of the updated maps into the American Society of Civil Engineers Minimum Design Loads for Building and Other Structures and the International Building and Residential Codes is underway. Relative to the ground motions in the prior edition of each of these documents, most of the updated values are within a ±20% change. The larger changes are, in most cases, due to the USGS NSHM updates, reasons for which are given in companion publications. In some cases, the larger changes are partly due to a BSSC update of the slope of the fragility curve that is used to calculate the risk-targeted ground motions, and/or the introduction by BSSC of a quantitative definition of “active faults” used to calculate deterministic ground motions.
Oliveira, Rayssa Cristiane; Elali, Gleice Azambuja
2012-01-01
This article discusses the quality of internal life space in apartments of residential buildings in the northeast region of Brazil, especially the possibility to adapt environments with small areas (according to local building codes) to the needs of different arrangements of families (considering 4 members per family). The research had a gradual approach and used multimethod strategy: (a) studying the universe of residential buildings whose apartment's inner area is between 50 and 60 m2 and were constructed in Natal-RN between 1998 and 2008, as well as not linked to social housing programs and occupied for more than one year; (b) selecting a building to do a Post Occupation Evaluation (POE), using walkthrough, technical observation and questionnaires; (c) choosing of two housing units to do an ergonomic intervention (based in interviews and detailed measurements). The results show the technical possibility to modify the units, but these modifications have a high (social, economic and environmental) price, because in general the space of units projected is not flexible. So, the paper concludes that this type of enterprise needs to be rethought, since part of them is (social and ecologically) unsustainable.
Cloud immersion building shielding factors for US residential structures.
Dickson, E D; Hamby, D M
2014-12-01
This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario within a semi-infinite cloud of radioactive material. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement, as well for single-wide manufactured housing-units.
Simplified Floor-Area-Based Energy-Moisture-Economic Model for Residential Buildings
ERIC Educational Resources Information Center
Martinez, Luis A.
2009-01-01
In the United States, 21% of all energy is used in residential buildings (40% of which is for heating and cooling homes). Promising improvements in residential building energy efficiency are underway such as the Building America Program and the Passive House Concept. The ability of improving energy efficiency in buildings is enhanced by building…
29 CFR 779.335 - Sales of building materials for residential or farm building construction.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 3 2010-07-01 2010-07-01 false Sales of building materials for residential or farm... for Certain Retail or Service Establishments Sales Not Made for Resale § 779.335 Sales of building... the category of sales for resale “the sale of goods to be used in residential or farm building...
29 CFR 779.335 - Sales of building materials for residential or farm building construction.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 3 2011-07-01 2011-07-01 false Sales of building materials for residential or farm... for Certain Retail or Service Establishments Sales Not Made for Resale § 779.335 Sales of building... the category of sales for resale “the sale of goods to be used in residential or farm building...
29 CFR 779.335 - Sales of building materials for residential or farm building construction.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 3 2013-07-01 2013-07-01 false Sales of building materials for residential or farm... for Certain Retail or Service Establishments Sales Not Made for Resale § 779.335 Sales of building... the category of sales for resale “the sale of goods to be used in residential or farm building...
29 CFR 779.335 - Sales of building materials for residential or farm building construction.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 3 2014-07-01 2014-07-01 false Sales of building materials for residential or farm... for Certain Retail or Service Establishments Sales Not Made for Resale § 779.335 Sales of building... the category of sales for resale “the sale of goods to be used in residential or farm building...
29 CFR 779.335 - Sales of building materials for residential or farm building construction.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 3 2012-07-01 2012-07-01 false Sales of building materials for residential or farm... for Certain Retail or Service Establishments Sales Not Made for Resale § 779.335 Sales of building... the category of sales for resale “the sale of goods to be used in residential or farm building...
Measure Guideline: Combustion Safety for Natural Draft Appliances Using Indoor Air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brand, L.
2014-04-01
This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is formore » inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.« less
Combustion Safety for Appliances Using Indoor Air (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-05-01
This measure guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate measure guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is formore » inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.« less
10 CFR 435.1 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-01-01
... OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.1 Purpose... Federal low-rise residential buildings as required by section 305(a) of the Energy Conservation and...
10 CFR 435.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.1 Purpose... Federal low-rise residential buildings as required by section 305(a) of the Energy Conservation and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
TESP combines existing domain simulators in the electric power grid, with new transactive agents, growth models and evaluation scripts. The existing domain simulators include GridLAB-D for the distribution grid and single-family residential buildings, MATPOWER for transmission and bulk generation, and EnergyPlus for large buildings. More are planned for subsequent versions of TESP. The new elements are: TEAgents - simulate market participants and transactive systems for market clearing. Some of this functionality was extracted from GridLAB-D and implemented in Python for customization by PNNL and others; Growth Model - a means for simulating system changes over a multiyear period, including bothmore » normal load growth and specific investment decisions. Customizable in Python code; and Evaluation Script - a means of evaluating different transactive systems through customizable post-processing in Python code. TESP provides a method for other researchers and vendors to design transactive systems, and test them in a virtual environment. It allows customization of the key components by modifying Python code.« less
Experimental Shielding Evaluation of the Radiation Protection Provided by Residential Structures
NASA Astrophysics Data System (ADS)
Dickson, Elijah D.
The human health and environmental effects following a postulated accidental release of radioactive material to the environment has been a public and regulatory concern since the early development of nuclear technology and researched extensively to better understand the potential risks for accident mitigation and emergency planning purposes. The objective of this investigation is to research and develop the technical basis for contemporary building shielding factors for the U.S. housing stock. Building shielding factors quantify the protection a certain building-type provides from ionizing radiation. Much of the current data used to determine the quality of shielding around nuclear facilities and urban environments is based on simplistic point-kernel calculations for 1950's era suburbia and is no longer applicable to the densely populated urban environments seen today. To analyze a building's radiation shielding properties, the ideal approach would be to subject a variety of building-types to various radioactive materials and measure the radiation levels in and around the building. While this is not entirely practicable, this research uniquely analyzes the shielding effectiveness of a variety of likely U.S. residential buildings from a realistic source term in a laboratory setting. Results produced in the investigation provide a comparison between theory and experiment behind building shielding factor methodology by applying laboratory measurements to detailed computational models. These models are used to develop a series of validated building shielding factors for generic residential housing units using the computational code MCNP5. For these building shielding factors to be useful in radiologic consequence assessments and emergency response planning, two types of shielding factors have been developed for; (1) the shielding effectiveness of each structure within a semi-infinite cloud of radioactive material, and (2) the shielding effectiveness of each structure from contaminant deposition on the roof and surrounding surfaces. For example, results from this investigation estimate the building shielding factors from a semi-infinite plume between comparable two-story models with a basement constructed with either brick-and-mortar or vinyl siding composing the exterior wall weather and a typical single-wide manufactured home with vinyl siding to be 0.36, 0.65, and 0.82 respectively.
Experimental study on lateral strength of wall-slab joint subjected to lateral cyclic load
NASA Astrophysics Data System (ADS)
Masrom, Mohd Asha'ari; Mohamad, Mohd Elfie; Hamid, Nor Hayati Abdul; Yusuff, Amer
2017-10-01
Tunnel form building has been utilised in building construction since 1960 in Malaysia. This method of construction has been applied extensively in the construction of high rise residential house (multistory building) such as condominium and apartment. Most of the tunnel form buildings have been designed according to British standard (BS) whereby there is no provision for seismic loading. The high-rise tunnel form buildings are vulnerable to seismic loading. The connections between slab and shear walls in the tunnel-form building constitute an essential link in the lateral load resisting mechanism. Malaysia is undergoing a shifting process from BS code to Eurocode (EC) for building construction since the country has realised the safety threats of earthquake. Hence, this study is intended to compare the performance of the interior wall slab joint for a tunnel form structure designed based on Euro and British codes. The experiment included a full scale test of the wall slab joint sub-assemblages under reversible lateral cyclic loading. Two sub-assemblage specimens of the wall slab joint were designed and constructed based on both codes. Each specimen was tested using lateral displacement control (drift control). The specimen designed by using Eurocode was found could survive up to 3.0% drift while BS specimen could last to 1.5% drift. The analysis results indicated that the BS specimen was governed by brittle failure modes with Ductility Class Low (DCL) while the EC specimen behaved in a ductile manner with Ductility Class Medium (DCM). The low ductility recorded in BS specimen was resulted from insufficient reinforcement provided in the BS code specimen. Consequently, the BS specimen could not absorb energy efficiently (low energy dissipation) and further sustain under inelastic deformation.
10 CFR 435.303 - Requirements for the design of a Federal residential building.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Requirements for the design of a Federal residential building. 435.303 Section 435.303 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-24
...] Hazard Mitigation Assistance for Wind Retrofit Projects for Existing Residential Buildings AGENCY... for Wind Retrofit Projects for Existing Residential Buildings. DATES: Comments must be received by... property from hazards and their effects. One such activity is the implementation of wind retrofit projects...
10 CFR 435.303 - Requirements for the design of a Federal residential building.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Requirements for the design of a Federal residential building. 435.303 Section 435.303 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nutaro, James J
The purpose of this model was to facilitate the design of a control system that uses fine grained control of residential and small commercial HVAC loads to counterbalance voltage swings caused by intermittent solar power sources (e.g., rooftop panels) installed in that distribution circuit. Included is the source code and pre-compiled 64 bit dll for adding building HVAC loads to an OpenDSS distribution circuit. As written, the Makefile assumes you are using the Microsoft C++ development tools.
Green buildings for Egypt: a call for an integrated policy
NASA Astrophysics Data System (ADS)
Bampou, P.
2017-11-01
As global warming is on the threshold of each country worldwide, Middle East and North African (MENA) region has already adopted energy efficiency (EE) policies on several consuming sectors. The present paper valuates the impact of temperature increase in the residential building sector of Egypt that is the most integrated example of the 7 out of the 20 MENA countries that have started their green efforts upon building environment. Furthermore, as it is based on a literature research upon socio-economic characteristics, existing building stock, existing legal and institutional framework, it elaborates a quantitative evaluation of Egypt's energy-saving potential, outlining basic constraints upon energy conservation, in order for Egypt to be able to handle the high energy needs due to its warm climate. Last but not least, the paper proposes a policy pathway for the implementation of green building codes and concludes with the best available technologies to promote EE in the Egyptian building sector.
NASA Astrophysics Data System (ADS)
Alsabry, A.; Truszkiewicz, P.; Szymański, K.; Łaskawiec, K.; Rojek, Ł.
2017-12-01
The article presents an analysis of buildings belonging the Department of Public Utilities and Housing in Zielona Góra. The research was based on a set of questions for building operators. The questionnaires consisted of 30 questions concerning general and detailed information about the buildings. In order to clearly present the results, this article includes data only about residential and residential-commercial buildings. Forty building built in different periods were selected for analysis.
12 CFR 541.16 - Improved residential real estate.
Code of Federal Regulations, 2010 CFR
2010-01-01
... improved residential real estate means residential real estate containing offsite or other improvements sufficient to make the property ready for primarily residential construction, and real estate in the process of being improved by a building or buildings to be constructed or in the process of construction for...
ATTRIBUTES OF FORM IN THE BUILT ENVIRONMENT THAT INFLUENCE PERCEIVED WALKABILITY.
Oreskovic, Nicolas M; Charles, Pablina Roth Suzanne Lanyi; Shepherd, Dido Tsigaridi Kathrine; Nelson, Kerrie P; Bar, Moshe
2014-01-01
A recent focus of design and building regulations, including form-based codes and the Leadership in Energy and Environmental Design for Neighborhood Development rating system, has been on promoting pedestrian activity. This study assessed perceptions of walkability for residential and commercial streetscapes with different design attributes in order to inform form-based regulations and codes that aim to impact walkability. We scored 424 images on four design attributes purported to influence walkability: variation in building height, variation in building plane, presence of ground-floor windows, and presence of a street focal point. We then presented the images to 45 adults, who were asked to rate the images for walkability. The results showed that perceived walkability varied according to the degree to which a particular design attribute was present, with the presence of ground-floor windows and a street focal point most consistently associated with a space's perceived walkability. Understanding if and which design attributes are most related to walkability could allow planners and developers to focus on the most salient built-environment features influencing physical activity, as well as provide empirical scientific evidence for form-based regulations and zoning codes aimed at impacting walkabilit.
Contaminant deposition building shielding factors for US residential structures.
Dickson, Elijah; Hamby, David; Eckerman, Keith
2017-10-10
This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit. © 2017 IOP Publishing Ltd.
Contaminant deposition building shielding factors for US residential structures.
Dickson, E D; Hamby, D M; Eckerman, K F
2015-06-01
This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit.
NASA Astrophysics Data System (ADS)
Tolga Çöğürcü, M.
2015-01-01
Turkey is situated in a very active earthquake region. In the last century, several earthquakes resulted in thousands of deaths and enormous economic losses. In 1999, the Marmara earthquake had an approximate death toll of more than 20 000, and in 2011, the Van earthquake killed 604 people. In general, Turkish residential buildings have reinforced concrete structural systems. These reinforced concrete structures have several deficiencies, such as low concrete quality, non-seismic steel detailing, and inappropriate structural systems including several architectural irregularities. In this study, the general characteristics of Turkish building stock and the deficiencies observed in structural systems are explained, and illustrative figures are given with reference to Turkish Earthquake Code 2007 (TEC, 2007). The poor concrete quality, lack of lateral or transverse reinforcement in beam-column joints and column confinement zones, high stirrup spacings, under-reinforced columns and over-reinforced beams are the primary causes of failures. Other deficiencies include weak column-stronger beam formations, insufficient seismic joint separations, soft story or weak story irregularities and short columns. Similar construction and design mistakes are also observed in other countries situated on active earthquake belts. Existing buildings still have these undesirable characteristics, so to prepare for future earthquakes, they must be rehabilitated.
NASA Astrophysics Data System (ADS)
Cogurcu, M. T.
2015-04-01
Turkey is situated in a very active earthquake region. In the last century, several earthquakes resulted in thousands of deaths and enormous economic losses. In 1999, the Kocaeli earthquake had an approximate death toll of more than 20 000, and in 2011 the Van earthquake killed 604 people. In general, Turkish residential buildings have reinforced concrete structural systems. These reinforced concrete structures have several deficiencies, such as low concrete quality, non-seismic steel detailing and inappropriate structural systems including several architectural irregularities. In this study, the general characteristics of Turkish building stock and the deficiencies observed in structural systems are explained, and illustrative figures are given with reference to the Turkish Earthquake Code 2007. The poor concrete quality, lack of lateral or transverse reinforcement in beam-column joints and column confinement zones, high stirrup spacings, under-reinforced columns and over-reinforced beams are the primary causes of failures. Other deficiencies include weak-column-stronger-beam formations, insufficient seismic joint separations, soft-story or weak-story irregularities and short columns. Similar construction and design mistakes are also observed in other countries situated on active earthquake belts. Existing buildings still have these undesirable characteristics, and so to prepare for future earthquakes they must be rehabilitated.
Harmful Materials and Residential Demolition
Certain harmful or problematic materials present in residential buildings may need to be handled differently from general demolition debris. Here is a list of several specific types of materials that may be present in residential buildings.
Analysis of the systems of ventilation of residential houses of Ukraine and Estonia
NASA Astrophysics Data System (ADS)
Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik
2017-12-01
The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.
Determination of sustainable values for the parameters of the construction of residential buildings
NASA Astrophysics Data System (ADS)
Grigoreva, Larisa; Grigoryev, Vladimir
2018-03-01
For the formation of programs for housing construction and planning of capital investments, when developing the strategic planning companies by construction companies, the norms or calculated indicators of the duration of the construction of high-rise residential buildings and multifunctional complexes are mandatory. Determination of stable values of the parameters for the high-rise construction residential buildings provides an opportunity to establish a reasonable duration of construction at the planning and design stages of residential complexes, taking into account the influence of market conditions factors. The concept of the formation of enlarged models for the high-rise construction residential buildings is based on a real mapping in time and space of the most significant redistribution with their organizational and technological interconnection - the preparatory period, the underground part, the above-ground part, external engineering networks, landscaping. The total duration of the construction of a residential building, depending on the duration of each redistribution and the degree of their overlapping, can be determined by one of the proposed four options. At the same time, a unified approach to determining the overall duration of construction on the basis of the provisions of a streamlined construction organization with the testing of results on the example of high-rise residential buildings of the typical I-155B series was developed, and the coefficients for combining the work and the main redevelopment of the building were determined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This report documents the development and testing of a set of recommendations generated to serve as a primary basis for the Congressionally-mandated residential standard. This report treats only the residential building recommendations.
Accessorizing Building Science – A Web Platform to Support Multiple Market Transformation Programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madison, Michael C.; Antonopoulos, Chrissi A.; Dowson, Scott T.
As demand for improved energy efficiency in homes increases, builders need information on the latest findings in building science, rapidly ramping-up energy codes, and technical requirements for labeling programs. The Building America Solution Center is a Department of Energy (DOE) website containing hundreds of expert guides designed to help residential builders install efficiency measures in new and existing homes. Builders can package measures with other media for customized content. Website content provides technical support to market transformation programs such as ENERGY STAR and has been cloned and adapted to provide content for the Better Buildings Residential Program. The Solution Centermore » uses the Drupal open source content management platform to combine a variety of media in an interactive manner to make information easily accessible. Developers designed a unique taxonomy to organize and manage content. That taxonomy was translated into web-based modules that allow users to rapidly traverse structured content with related topics, and media. We will present information on the current design of the Solution Center and the underlying technology used to manage the content. The paper will explore development of features, such as “Field Kits” that allow users to bundle and save content for quick access, along with the ability to export PDF versions of content. Finally, we will discuss development of an Android based mobile application, and a visualization tool for interacting with Building Science Publications that allows the user to dynamically search the entire Building America Library.« less
Effects of internal gain assumptions in building energy calculations
NASA Astrophysics Data System (ADS)
Christensen, C.; Perkins, R.
1981-01-01
The utilization of direct solar gains in buildings can be affected by operating profiles, such as schedules for internal gains, thermostat controls, and ventilation rates. Building energy analysis methods use various assumptions about these profiles. The effects of typical internal gain assumptions in energy calculations are described. Heating and cooling loads from simulations using the DOE 2.1 computer code are compared for various internal gain inputs: typical hourly profiles, constant average profiles, and zero gain profiles. Prototype single-family-detached and multifamily-attached residential units are studied with various levels of insulation and infiltration. Small detached commercial buildings and attached zones in large commercial buildings are studied with various levels of internal gains. The results indicate that calculations of annual heating and cooling loads are sensitive to internal gains, but in most cases are relatively insensitive to hourly variations in internal gains.
Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.
ERIC Educational Resources Information Center
Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.
This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…
10 CFR 433.3 - Materials incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CONSTRUCTION OF NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS § 433.3 Materials... Buildings Except Low-Rise Residential Buildings, January 2004, American Society of Heating Refrigerating and...
10 CFR 433.3 - Materials incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... CONSTRUCTION OF NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS § 433.3 Materials... Buildings Except Low-Rise Residential Buildings, January 2004, American Society of Heating Refrigerating and...
Technology Solutions Case Study: Cladding Attachment Over Thick Exterior Insulating Sheathing
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. Insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. Although the approach has proven effective, there is resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the verticalmore » displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly. In this project, researchers from Building Science Corporation, a Building America team, investigated these issues to better understand the mechanics behind this method of cladding attachment« less
A new urban planning code's impact on walking: the residential environments project.
Christian, Hayley; Knuiman, Matthew; Bull, Fiona; Timperio, Anna; Foster, Sarah; Divitini, Mark; Middleton, Nicholas; Giles-Corti, Billie
2013-07-01
We examined whether people moving into a housing development designed according to a state government livable neighborhoods subdivision code engage in more walking than do people who move to other types of developments. In a natural experiment of 1813 people building homes in 73 new housing developments in Perth, Western Australia, we surveyed participants before and then 12 and 36 months after moving. We measured self-reported walking using the Neighborhood Physical Activity Questionnaire and collected perceptions of the environment and self-selection factors. We calculated objective measures of the built environment using a Geographic Information System. After relocation, participants in livable versus conventional developments had greater street connectivity, residential density, land use mix, and access to destinations and more positive perceptions of their neighborhood (all P < .05). However, there were no significant differences in walking over time by type of development (P > .05). Implementation of the Livable Neighborhoods Guidelines produced more supportive environments; however, the level of intervention was insufficient to encourage more walking. Evaluations of new urban planning policies need to incorporate longer term follow-up to allow time for new neighborhoods to develop.
Technical Problems of Residential Construction
NASA Astrophysics Data System (ADS)
Nowogońska, Beata; Cibis, Jerzy
2017-10-01
Beauty, utility, durability - these are the features of good architecture and should also be the distinguishing qualities of every residential building. But do beauty and utility remain along with the passing of time? Performance characteristics are an indicator of both, the technical as well as aesthetic state of buildings. Aesthetic needs are in disagreement with the merciless aging process. The beauty of a city is formed not only by the original forms of new residential buildings, but also by existing tenement housing; thus preserving their aesthetics becomes a necessity. Time is continuously passing and along with it, aging intensifies. The aging process is a natural phenomenon for every material. The life expectancy of building materials is also limited. Along with the passing of time, the technical state of residential buildings continuously deteriorates. With the passing of time, the aesthetic values and preferences of users of flats change and the usability of the building decreases. The permanence of buildings, including residential buildings, is shaped not only by the forces of nature but also by activities of humans. A long lifespan is ensured by carrying out ongoing, systematic renovation-repair works. It is thanks to them that buildings derived from past centuries are still being used, and their market attractiveness is not decreasing.
Development of photovoltaic array and module safety requirements
NASA Technical Reports Server (NTRS)
1982-01-01
Safety requirements for photovoltaic module and panel designs and configurations likely to be used in residential, intermediate, and large-scale applications were identified and developed. The National Electrical Code and Building Codes were reviewed with respect to present provisions which may be considered to affect the design of photovoltaic modules. Limited testing, primarily in the roof fire resistance field was conducted. Additional studies and further investigations led to the development of a proposed standard for safety for flat-plate photovoltaic modules and panels. Additional work covered the initial investigation of conceptual approaches and temporary deployment, for concept verification purposes, of a differential dc ground-fault detection circuit suitable as a part of a photovoltaic array safety system.
Technical Support Document for Version 3.4.0 of the COMcheck Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan
2007-09-14
COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards.« less
Lamers, Audri; van Nieuwenhuizen, Chijs; Twisk, Jos; de Koning, Erica; Vermeiren, Robert
2016-01-01
In a semi-residential setting where children switch daily between treatment and home, establishment of a strong parent-team alliance can be a challenge. The development of alliance with parents and the symptoms of the child might be strengthened by a structured investment of treatment team members. Participants were caregivers and treatment team members of 46 children (6-12 years) who received semi-residential psychiatric treatment. An A-B design was applied, in which the first 22 children were assigned to the comparison group receiving treatment as usual and the next 24 to the experimental group, where treatment team members used additional alliance-building strategies. Alliance and symptom questionnaires were filled out at three-month intervals during both treatment conditions. Parent-treatment team interactions, assessed on DVD, were coded according to members' adherence to these strategies. Multilevel analyses (using MLwiN) showed that based on reports of primary caregivers and a case manager, the alliance-building strategies had a statistically significant effect on the strength of the therapeutic alliance between treatment team members and parents. In addition, primary caregivers in the experimental group reported significant less hyperactivity symptoms of their children. Despite the methodological challenge of examining therapeutic processes in this complex treatment setting, this study supports the benefits of structured investment in the parent-team alliance.
1. EXTERIOR OF BUILDING 125 FROM MAIN PLANT 4 RESIDENTIAL ...
1. EXTERIOR OF BUILDING 125 FROM MAIN PLANT 4 RESIDENTIAL STREET SHOWING BUILDING AT PHOTO RIGHT CENTER (WITH WHITE JEEP PARKED IN FRONT) BETWEEN WORKER COTTAGE (BUILDING 115) AT PHOTO LEFT AND RECREATION HALL (BUILDING 109) AT PHOTO RIGHT. VIEW TO SOUTH. - Bishop Creek Hydroelectric System, Plant 4, Lightning Arrestor Vault, Bishop Creek, Bishop, Inyo County, CA
Measure Guideline. Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rudd, Armin
2012-08-01
This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.
The importance of the criteria of residential buildings from the perspective of future users
NASA Astrophysics Data System (ADS)
Sirochmanová, Lenka; Kozlovská, Mária; Bašková, Renáta
2016-06-01
The developers need to know what is important to their customers in preparation of new construction of residential buildings. The paper deals with finding the importance of structure, material, cost, time and environmental criteria of residential buildings from the perspective of the future owners. The research methodology that provided the information was questionnaire survey. Research was conducted in two lines. The first line is dedicated to the research of main construction domains of residential building. The second line of the research deals with the specific criteria of main construction domains. The order of importance of the main areas and the specific criteria is determined by analyzing of data through descriptive characteristics: median, modus, variance, average value and by weigh of importance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tabares-Velasco, P. C.; Christensen, C.; Bianchi, M.
2012-08-01
Phase change materials (PCM) represent a potential technology to reduce peak loads and HVAC energy consumption in residential buildings. This paper summarizes NREL efforts to obtain accurate energy simulations when PCMs are modeled in residential buildings: the overall methodology to verify and validate Conduction Finite Difference (CondFD) and PCM algorithms in EnergyPlus is presented in this study. It also shows preliminary results of three residential building enclosure technologies containing PCM: PCM-enhanced insulation, PCM impregnated drywall and thin PCM layers. The results are compared based on predicted peak reduction and energy savings using two algorithms in EnergyPlus: the PCM and Conductionmore » Finite Difference (CondFD) algorithms.« less
Construction and demolition waste indicators.
Mália, Miguel; de Brito, Jorge; Pinheiro, Manuel Duarte; Bravo, Miguel
2013-03-01
The construction industry is one of the biggest and most active sectors of the European Union (EU), consuming more raw materials and energy than any other economic activity. Furthermore, construction waste is the commonest waste produced in the EU. Current EU legislation sets out to implement construction and demolition waste (CDW) prevention and recycling measures. However it lacks tools to accelerate the development of a sector as bound by tradition as the building industry. The main objective of the present study was to determine indicators to estimate the amount of CDW generated on site both globally and by waste stream. CDW generation was estimated for six specific sectors: new residential construction, new non-residential construction, residential demolition, non-residential demolition, residential refurbishment, and non-residential refurbishment. The data needed to develop the indicators was collected through an exhaustive survey of previous international studies. The indicators determined suggest that the average composition of waste generated on site is mostly concrete and ceramic materials. Specifically for new residential and new non-residential construction the production of concrete waste in buildings with a reinforced concrete structure lies between 17.8 and 32.9 kg m(-2) and between 18.3 and 40.1 kg m(-2), respectively. For the residential and non-residential demolition sectors the production of this waste stream in buildings with a reinforced concrete structure varies from 492 to 840 kg m(-2) and from 401 to 768 kg/m(-2), respectively. For the residential and non-residential refurbishment sectors the production of concrete waste in buildings lies between 18.9 and 45.9 kg/m(-2) and between 18.9 and 191.2 kg/m(-2), respectively.
Ren, Kai; Xu, Leiqing
2017-10-01
The data related in this paper are related to "Environmental-behavior studies of sustainable construction of the third place - based on outdoor environment-behavior cross-feed symbiotic analysis and verification of selective activities" (Ren, 2017) [1]. The dataset was from a field sub-time extended investigation to children of Hohhot West Inner Mongolia Electric Power Community Residential Area in Inner Mongolia of China that belongs to cold region of ID area according to Chinese design code for buildings. This filed data provided descriptive statistics about outdoor time, behavior scale specificity, age exclusivity and self-centeredness for children in different ages (babies, preschool children, school age children). This data provided five measurement elements of child-friendly space and their weight ratio. The field data set is made publicly available to enable critical or extended analyzes.
Automatic Residential/Commercial Classification of Parcels with Solar Panel Detections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morton, April M; Omitaomu, Olufemi A; Kotikot, Susan
A computational method to automatically detect solar panels on rooftops to aid policy and financial assessment of solar distributed generation. The code automatically classifies parcels containing solar panels in the U.S. as residential or commercial. The code allows the user to specify an input dataset containing parcels and detected solar panels, and then uses information about the parcels and solar panels to automatically classify the rooftops as residential or commercial using machine learning techniques. The zip file containing the code includes sample input and output datasets for the Boston and DC areas.
Zhang, Pei-feng; Hu, Yuan-man; He, Hong-shi; Xiong, Zai-ping; Liu, Miao
2010-12-01
In this paper, three-dimensional building information was extracted from high resolution satellite image based on Barista software. Combined with ArcGIS software, the dynamic changes of the building landscape in Tiexi District of Shenyang City during urban renewal process were analyzed from the conversion contribution rate, building density, average building height, and built-up area rate. It was found that during this urban renewal process, four dominant landscape types (vacant lot, residential building, industrial building, and road) were the main parts of the landscape changes. The areas of vacant lot, residential building, commercial building, and road increased, while that of industrial building decreased. The building density decreased, while the average building height increased. There was an obvious regional variation in building landscape. The building density in industrial district was higher than that in residential district, while the average building height was in adverse. The further from the city center, the lower the building density and building average height.
Building a Community of Learning through Early Residential Fieldwork
ERIC Educational Resources Information Center
Walsh, Cathy; Larsen, Carl; Parry, Damian
2014-01-01
The positioning of residential fieldwork early in students' higher education is an established way of attempting to build and engage them in a community of learning. In the study reported here, the benefits of such early residential fieldwork were investigated using Krausse and Coates's seven scales of engagement. These scales consider a number of…
Analysis Thermal Comfort Condition in Complex Residential Building, Case Study: Chiangmai, Thailand
NASA Astrophysics Data System (ADS)
Juangjandee, Warangkana
2017-10-01
Due to the increasing need for complex residential buildings, it appears that people migrate into the high-density urban areas because the infrastructural facilities can be easily found in the modern metropolitan areas. Such rapid growth of urbanization creates congested residential buildings obstructing solar radiation and wind flow, whereas most urban residents spend 80-90% of their time indoor. Furthermore, the buildings were mostly built with average materials and construction detail. This causes high humidity condition for tenants that could promote mould growth. This study aims to analyse thermal comfort condition in complex residential building, Thailand for finding the passive solution to improve indoor air quality and respond to local conditions. The research methodology will be in two folds: 1) surveying on case study 2) analysis for finding the passive solution of reducing humidity indoor air The result of the survey indicated that the building need to find passive solution for solving humidity problem, that can be divided into two ways which raising ventilation and indoor temperature including increasing wind-flow ventilation and adjusting thermal temperature, for example; improving building design and stack driven ventilation. For raising indoor temperature or increasing mean radiant temperature, daylight can be passive solution for complex residential design for reducing humidity and enhance illumination indoor space simultaneous.
NASA Astrophysics Data System (ADS)
Kolobova, Svetlana
2018-03-01
As you know, high-rise construction is an indicator of the practical implementation of advanced innovative technologies in the construction industry of the country. High-rise building inevitably comes to the big cities, in connection with the shortage and value of land. The life cycle of any construction project, including high-rise buildings consists of chains: of engineering survey - design-construction-operation. In the process of operation of a tall building, decisions about major repairs or reconstruction of a building are made for decision-making on further use. This article describes methods of assessing the consumer quality of high-rise residential buildings and the establishment of prices based on consumer characteristics of a tall residential building. It is proposed to assess the premises under their quality characteristics. The study was conducted to establish the influence of individual, comprehensive and integral indicators of comparable quality for effective quality living spaces. Simultaneously, there was established a relationship of quality with the consumer cost of housing, ultimately with the potential needs of owners, tenants of the home, lessor dwelling, or buyers of residential properties and other participants in the residential real estate market. This relationship further creates consumer requirements to quality standard of premises at a certain stage of socio-economic development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-11-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less
Three empirical essays on consumer behavior related to climate change and energy
NASA Astrophysics Data System (ADS)
Jacobsen, Grant Douglas
This dissertation consists of three essays. All of the chapters address a topic in the area of household and consumer behavior related to climate change or energy. The first chapter is titled "The Al Gore Effect: An Inconvenient Truth and Voluntary Carbon Offsets". This chapter examines the relationship between climate change awareness and household behavior by testing whether Al Gore's documentary An Inconvenient Truth caused an increase in the purchase of voluntary carbon offsets. The analysis shows that in the two months following the film's release, zip codes within a 10-mile radius of a zip code where the film was shown experienced a 50 percent relative increase in the purchase of voluntary carbon offsets. The second chapter is titled "Are Building Codes Effective at Saving Energy? Evidence from Residential Billing Data in Florida". The analysis shows that Florida's energy-code change that took effect in 2002 is associated with a 4-percent decrease in electricity consumption and a 6-percent decrease in natural-gas consumption in Gainesville, FL. The estimated private payback period for the average residence is 6.4 years and the social payback period ranges between 3.5 and 5.3 years. The third chapter in this dissertation is titled "Do Environmental Offsets Increase Demand for Dirty Goods? Evidence from Residential Electricity Demand". This study evaluates the relationship between green products and existing patterns of consumer behavior by examining the relationship between household enrollment in a green electricity program and consumption of residential electricity. The results suggest there are two different types of green consumers. One type makes a small monthly donation and partially views the donation as a substitute for a previously existing pattern of green behavior, in this case, energy conservation. The other type makes a larger monthly donation and views the donation as a way to make strictly additional improvements in environmental quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
New, Joshua Ryan; Kumar, Jitendra; Hoffman, Forrest M.
Statement of the Problem: ASHRAE releases updates to 90.1 “Energy Standard for Buildings except Low-Rise Residential Buildings” every three years resulting in a 3.7%-17.3% increase in energy efficiency for buildings with each release. This is adopted by or informs building codes in nations across the globe, is the National Standard for the US, and individual states elect which release year of the standard they will enforce. These codes are built upon Standard 169 “Climatic Data for Building Design Standards,” the latest 2017 release of which defines climate zones based on 8, 118 weather stations throughout the world and data frommore » the past 8-25 years. This data may not be indicative of the weather that new buildings built today, will see during their upcoming 30-120 year lifespan. Methodology & Theoretical Orientation: Using more modern, high-resolution datasets from climate satellites, IPCC climate models (PCM and HadGCM), high performance computing resources (Titan) and new capabilities for clustering and optimization the authors briefly analyzed different methods for redefining climate zones. Using bottom-up analysis of multiple meteorological variables which were the subject matter, experts selected as being important to energy consumption, rather than the heating/cooling degree days currently used. Findings: We analyzed the accuracy of redefined climate zones, compared to current climate zones and how the climate zones moved under different climate change scenarios, and quantified the accuracy of these methods on a local level, at a national scale for the US. Conclusion & Significance: There is likely to be a significant annual, national energy and cost (billions USD) savings that could be realized by adjusting climate zones to take into account anticipated trends or scenarios in regional weather patterns.« less
Probabilistic modeling of the indoor climates of residential buildings using EnergyPlus
Buechler, Elizabeth D.; Pallin, Simon B.; Boudreaux, Philip R.; ...
2017-04-25
The indoor air temperature and relative humidity in residential buildings significantly affect material moisture durability, HVAC system performance, and occupant comfort. Therefore, indoor climate data is generally required to define boundary conditions in numerical models that evaluate envelope durability and equipment performance. However, indoor climate data obtained from field studies is influenced by weather, occupant behavior and internal loads, and is generally unrepresentative of the residential building stock. Likewise, whole-building simulation models typically neglect stochastic variables and yield deterministic results that are applicable to only a single home in a specific climate. The
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1989-09-01
The objective of this environmental assessment (EA) is to identify the potential environmental impacts that could result from the proposed voluntary residential standard (VOLRES) on private sector construction of new residential buildings. In this report, the scope, objectives, and approach of this EA are presented.
NASA Astrophysics Data System (ADS)
Wang, Ruozhu; Liu, Pengda; Qian, Yongmei
2018-02-01
This paper analyzes the design technology of controlling indoor quality in engineering practice, it is proposed that, in framework system of green residential building design, how to realize the design idea of controlling the indoor environment quality, and the design technology with feasibility, including the sunshine and lighting, indoor air quality and thermal environment, sound insulation and noise reduction measures, etc.. The results of all will provide a good theoretical supportting for the design of green residential building.
Technical Support Document for Version 3.9.0 of the COMcheck Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan
2011-09-01
COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards. Beginning with COMcheck version 3.8.0, support for 90.1-1989, 90.1-1999, and the 1998 IECC are no longer included, but those sections remain in this document for reference purposes.« less
Technical Support Document for Version 3.9.1 of the COMcheck Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan
2012-09-01
COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards. Beginning with COMcheck version 3.8.0, support for 90.1-1989, 90.1-1999, and the 1998 IECC and version 3.9.0 support for 2000 and 2001 IECC are no longer included, but those sections remain in this document for reference purposes.« less
NASA Astrophysics Data System (ADS)
Zobin, V. M.; Cruz-Bravo, A. A.; Ventura-Ramírez, F.
2010-06-01
A macroseismic methodology of seismic risk microzonation in a low-rise city based on the vulnerability of residential buildings is proposed and applied to Colima city, Mexico. The seismic risk microzonation for Colima consists of two elements: the mapping of residential blocks according to their vulnerability level and the calculation of an expert-opinion based damage probability matrix (DPM) for a given level of earthquake intensity and a given type of residential block. A specified exposure time to the seismic risk for this zonation is equal to the interval between two destructive earthquakes. The damage probability matrices were calculated for three types of urban buildings and five types of residential blocks in Colima. It was shown that only 9% of 1409 residential blocks are able to resist to the Modify Mercalli (MM) intensity VII and VIII earthquakes without significant damage. The proposed DPM-2007 is in good accordance with the experimental damage curves based on the macroseismic evaluation of 3332 residential buildings in Colima that was carried out after the 21 January 2003 intensity MM VII earthquake. This methodology and the calculated PDM-2007 curves may be applied also to seismic risk microzonation for many low-rise cities in Latin America, Asia, and Africa.
Clean Energy in City Codes: A Baseline Analysis of Municipal Codification across the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, Jeffrey J.; Aznar, Alexandra; Dane, Alexander
Municipal governments in the United States are well positioned to influence clean energy (energy efficiency and alternative energy) and transportation technology and strategy implementation within their jurisdictions through planning, programs, and codification. Municipal governments are leveraging planning processes and programs to shape their energy futures. There is limited understanding in the literature related to codification, the primary way that municipal governments enact enforceable policies. The authors fill the gap in the literature by documenting the status of municipal codification of clean energy and transportation across the United States. More directly, we leverage online databases of municipal codes to develop nationalmore » and state-specific representative samples of municipal governments by population size. Our analysis finds that municipal governments with the authority to set residential building energy codes within their jurisdictions frequently do so. In some cases, communities set codes higher than their respective state governments. Examination of codes across the nation indicates that municipal governments are employing their code as a policy mechanism to address clean energy and transportation.« less
10 CFR 435.6 - Sustainable principles for siting, design and construction. [Reserved
Code of Federal Regulations, 2011 CFR
2011-01-01
... FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.6 Sustainable principles for siting, design and construction...
10 CFR 435.6 - Sustainable principles for siting, design and construction. [Reserved
Code of Federal Regulations, 2010 CFR
2010-01-01
... FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.6 Sustainable principles for siting, design and construction...
2. EXTERIOR NORTH CORNER OF BUILDING 106 FROM MAIN RESIDENTIAL ...
2. EXTERIOR NORTH CORNER OF BUILDING 106 FROM MAIN RESIDENTIAL STREET. CONCRETE WALKWAY FROM STREET TO FRONT SCREENED-IN PORCH IS VISIBLE AT PHOTO CENTER. BUILDING 115 IS AT PHOTO RIGHT BACKGROUND. VIEW TO SOUTHEAST. - Bishop Creek Hydroelectric System, Plant 4, Worker Cottage, Bishop Creek, Bishop, Inyo County, CA
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Definitions. 433.2 Section 433.2 Energy DEPARTMENT OF...-RISE RESIDENTIAL BUILDINGS § 433.2 Definitions. For purposes of this part, the following terms, phrases... Analysis of Federal Programs.” Low-rise residential building means any building three stories or less in...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Definitions. 433.2 Section 433.2 Energy DEPARTMENT OF...-RISE RESIDENTIAL BUILDINGS § 433.2 Definitions. For purposes of this part, the following terms, phrases... Analysis of Federal Programs.” Low-rise residential building means any building three stories or less in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2014-11-01
This 2014 Top Innovations profile describes Building America research and support in developing and gaining adoption of ASHRAE 62.2, a residential ventilation standard that is critical to transforming the U.S. housing industry to high-performance homes.
Procedures and Standards for Residential Ventilation System Commissioning: An Annotated Bibliography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stratton, J. Chris; Wray, Craig P.
2013-04-01
Beginning with the 2008 version of Title 24, new homes in California must comply with ANSI/ASHRAE Standard 62.2-2007 requirements for residential ventilation. Where installed, the limited data available indicate that mechanical ventilation systems do not always perform optimally or even as many codes and forecasts predict. Commissioning such systems when they are installed or during subsequent building retrofits is a step towards eliminating deficiencies and optimizing the tradeoff between energy use and acceptable IAQ. Work funded by the California Energy Commission about a decade ago at Berkeley Lab documented procedures for residential commissioning, but did not focus on ventilation systems.more » Since then, standards and approaches for commissioning ventilation systems have been an active area of work in Europe. This report describes our efforts to collect new literature on commissioning procedures and to identify information that can be used to support the future development of residential-ventilation-specific procedures and standards. We recommend that a standardized commissioning process and a commissioning guide for practitioners be developed, along with a combined energy and IAQ benefit assessment standard and tool, and a diagnostic guide for estimating continuous pollutant emission rates of concern in residences (including a database that lists emission test data for commercially-available labeled products).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report provides an overview of the U.S. Department of Energy Building America program's Summer 2011 Residential Energy Efficiency Technical Update Meeting. This meeting was held on August 9-11, 2011, in Denver, Colorado, and brought together more than 290 professionals representing organizations with a vested interest in energy efficiency improvements in residential buildings.
Smart ventilation energy and indoor air quality performance in residential buildings: A review
Guyot, Gaelle; Sherman, Max H.; Walker, Iain S.
2017-12-30
To better address energy and indoor air quality issues, ventilation needs to become smarter. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or indoor air quality (IAQ) advantage (or both) and less when it provides a disadvantage. A favorable context exists in many countries to include some of the existing smart ventilation strategies in codes and standards. As a result, demand-controlled ventilation (DCV) systems are widely and easily available on the market, with more than 20 DCV systems approved and available in countries such as Belgium, France and themore » Netherlands. This paper provides a literature review on smart ventilation used in residential buildings, based on energy and indoor air quality performance. This meta-analysis includes 38 studies of various smart ventilation systems with control based on CO 2, humidity, combined CO 2 and total volatile organic compounds (TVOC), occupancy, or outdoor temperature. In conclusion, these studies show that ventilation energy savings up to 60% can be obtained without compromising IAQ, even sometimes improving it. However, the meta-analysis included some less than favorable results, with 26% energy overconsumption in some cases.« less
Smart ventilation energy and indoor air quality performance in residential buildings: A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guyot, Gaelle; Sherman, Max H.; Walker, Iain S.
To better address energy and indoor air quality issues, ventilation needs to become smarter. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or indoor air quality (IAQ) advantage (or both) and less when it provides a disadvantage. A favorable context exists in many countries to include some of the existing smart ventilation strategies in codes and standards. As a result, demand-controlled ventilation (DCV) systems are widely and easily available on the market, with more than 20 DCV systems approved and available in countries such as Belgium, France and themore » Netherlands. This paper provides a literature review on smart ventilation used in residential buildings, based on energy and indoor air quality performance. This meta-analysis includes 38 studies of various smart ventilation systems with control based on CO 2, humidity, combined CO 2 and total volatile organic compounds (TVOC), occupancy, or outdoor temperature. In conclusion, these studies show that ventilation energy savings up to 60% can be obtained without compromising IAQ, even sometimes improving it. However, the meta-analysis included some less than favorable results, with 26% energy overconsumption in some cases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calio, I.; Cannizzaro, F.; Marletta, M.
2008-07-08
In the present study a new discrete-element approach for the evaluation of the seismic resistance of composite reinforced concrete-masonry structures is presented. In the proposed model, unreinforced masonry panels are modelled by means of two-dimensional discrete-elements, conceived by the authors for modelling masonry structures, whereas the reinforced concrete elements are modelled by lumped plasticity elements interacting with the masonry panels through nonlinear interface elements. The proposed procedure was adopted for the assessment of the seismic response of a case study confined-masonry building which was conceived to be a typical representative of a wide class of residential buildings designed to themore » requirements of the 1909 issue of the Italian seismic code and widely adopted in the aftermath of the 1908 earthquake for the reconstruction of the cities of Messina and Reggio Calabria.« less
Public policy for solar heating and cooling
NASA Technical Reports Server (NTRS)
Hirshberg, A. S.
1976-01-01
Recent analyses indicated that solar heating and cooling systems for residential buildings are nearly economically competitive with conventional fossil fuel or electric systems, the former having higher initial cost but a lower operating cost than the latter. The paper examines obstacles to the widespread acceptance and use of solar space conditioning systems and explores some general policies which could help to overcome them. The discussion covers such institutional barriers limiting the adoption of solar technologies as existing building codes, financing constraints, and organizational structure of the building industry. The potential impact of financial incentives is analyzed. It is noted that a tax incentive of 25% could speed the use of solar energy by 7 to 8 years and produce an 8% reduction in fossil fuel use by 1990. A preliminary incentive package which could be helpful in promoting solar energy both at federal and state levels is proposed, and the necessary incentive level is analysed.
NASA Astrophysics Data System (ADS)
Caliò, I.; Cannizzaro, F.; D'Amore, E.; Marletta, M.; Pantò, B.
2008-07-01
In the present study a new discrete-element approach for the evaluation of the seismic resistance of composite reinforced concrete-masonry structures is presented. In the proposed model, unreinforced masonry panels are modelled by means of two-dimensional discrete-elements, conceived by the authors for modelling masonry structures, whereas the reinforced concrete elements are modelled by lumped plasticity elements interacting with the masonry panels through nonlinear interface elements. The proposed procedure was adopted for the assessment of the seismic response of a case study confined-masonry building which was conceived to be a typical representative of a wide class of residential buildings designed to the requirements of the 1909 issue of the Italian seismic code and widely adopted in the aftermath of the 1908 earthquake for the reconstruction of the cities of Messina and Reggio Calabria.
Energy efficiency to reduce residential electricity and natural gas use under climate change.
Reyna, Janet L; Chester, Mikhail V
2017-05-15
Climate change could significantly affect consumer demand for energy in buildings, as changing temperatures may alter heating and cooling loads. Warming climates could also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy efficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41-87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy efficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand.
Energy efficiency to reduce residential electricity and natural gas use under climate change
NASA Astrophysics Data System (ADS)
Reyna, Janet L.; Chester, Mikhail V.
2017-05-01
Climate change could significantly affect consumer demand for energy in buildings, as changing temperatures may alter heating and cooling loads. Warming climates could also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy efficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41-87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy efficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand.
NASA Astrophysics Data System (ADS)
Marpaung, B. O. Y.; Waginah
2018-03-01
Every existence of community settlements that formed has related to social, culture, and economy that exists in that society. Participation is a process that involving human interaction towards each other, of these interactions creates activities that potentially form a new space (Hendriksen, et al., 2012). Problems in this research are related to community involvement in building residential, determining land used, building roads, and utilities in Kampung Nelayan Belawan Medan residential. The aim of this research is to find the community involvement of building residential, determining land used, building roads, and utilities in Kampung Nelayan Belawan Medan residential. In the process of collecting data, researchers conducted field observation and interviews. Then the researchers connect the theory and interpretation of data in determining the method of data analysis. Then the researchers connect the theory and interpretation of data in determining the method of data analysis. The discovery of this research is that the formation of settlement spaces in the fishing village is inseparable from the participation in Kampung Nelayan Belawan Medan residential.
Mean wind speed below building height in residential neighborhoods with different tree densities
G.M. Heisler
1990-01-01
There is little available knowledge of the absolute or relative effects of trees and buildings on wind at or below building height in residential neighborhoods. In this study, mean wind speed was measured at a height of 6.6 ft (2 m) in neighborhoods of single-family houses. BuIlding densities ranged between 6% and 12% of the land ares, and tree-cover densities were...
Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klocke, S.; Faakye, O.; Puttagunta, S.
2014-10-01
While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-risemore » multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.« less
How EPA's Asbestos Regulations Apply to Residential Buildings Used for Fire Training
Memos and guidance from the Office of Air Quality Planning and Standards that clarify how the Asbestos National Emissions Standard for Hazardous Air Pollutants applies to residential buildings used for fire training, also known as acquired structures.
The post-evaluation of green residential building in Ningxia
NASA Astrophysics Data System (ADS)
Wu, Yunna; Wang, Zhen
2017-06-01
Green residential buildings are concerned by more and more people. However, the development of green residential buildings has been limited due to the single-standard requirements and lack of the multi-objective performance. At same time, the evaluation criteria system of green residential building is not comprehensive enough. So first of all, using SPSS software, residents questionnaire surveys are figured and found that the judge of experts and residents about the green elements is inconsistent, so the owners’ satisfaction is included in the post-evaluation criterial systems of green residential building from five aspects-the preliminary work of construction, construction process, economic, social benefits and owners satisfaction in Ningxia area, combined with expert interviews. Secondly, in the post-evaluation, it is difficult for many experts judgment matrix to meet the requirement of consistency, in this paper using MATLAB program, judgment matrix consistency is adjusted. And the weights of the criteria and sub-criteria and experts weights using group AHP method are determined. Finally, the grey clustering method is used to establish the post-evaluation model and the real case of Sai-shang project is carried out. It shows that the result obtained by using the improved criteria system and method in this paper is in a high degree of agreement with the actual result.
Structural Code Considerations for Solar Rooftop Installations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dwyer, Stephen F.; Dwyer, Brian P.; Sanchez, Alfred
2014-12-01
Residential rooftop solar panel installations are limited in part by the high cost of structural related code requirements for field installation. Permitting solar installations is difficult because there is a belief among residential permitting authorities that typical residential rooftops may be structurally inadequate to support the additional load associated with a photovoltaic (PV) solar installation. Typical engineering methods utilized to calculate stresses on a roof structure involve simplifying assumptions that render a complex non-linear structure to a basic determinate beam. This method of analysis neglects the composite action of the entire roof structure, yielding a conservative analysis based on amore » rafter or top chord of a truss. Consequently, the analysis can result in an overly conservative structural analysis. A literature review was conducted to gain a better understanding of the conservative nature of the regulations and codes governing residential construction and the associated structural system calculations.« less
NASA Astrophysics Data System (ADS)
Sil, Arjun; Longmailai, Thaihamdau
2017-09-01
The lateral displacement of Reinforced Concrete (RC) frame building during an earthquake has an important impact on the structural stability and integrity. However, seismic analysis and design of RC building needs more concern due to its complex behavior as the performance of the structure links to the features of the system having many influencing parameters and other inherent uncertainties. The reliability approach takes into account the factors and uncertainty in design influencing the performance or response of the structure in which the safety level or the probability of failure could be ascertained. This present study, aims to assess the reliability of seismic performance of a four storey residential RC building seismically located in Zone-V as per the code provisions given in the Indian Standards IS: 1893-2002. The reliability assessment performed by deriving an explicit expression for maximum roof-lateral displacement as a failure function by regression method. A total of 319, four storey RC buildings were analyzed by linear static method using SAP2000. However, the change in the lateral-roof displacement with the variation of the parameters (column dimension, beam dimension, grade of concrete, floor height and total weight of the structure) was observed. A generalized relation established by regression method which could be used to estimate the expected lateral displacement owing to those selected parameters. A comparison made between the displacements obtained from analysis with that of the equation so formed. However, it shows that the proposed relation could be used directly to determine the expected maximum lateral displacement. The data obtained from the statistical computations was then used to obtain the probability of failure and the reliability.
Kim, Dongsu; Cox, Sam J.; Cho, Heejin; ...
2017-05-22
Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Dongsu; Cox, Sam J.; Cho, Heejin
Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less
2015-11-03
author(s) and should not contrued as an official Department of the Army position, policy or decision, unless so designated by other documentation. 9...Grass; 6 Undeveloped-Open Land (generally gravel or bare soil); Pavement ; Buildings and Concrete; and Residential Buildings (TG-ECT site only...pervious surfaces, while pavement , buildings and concrete, and residential buildings represent impervious surfaces. 2.3. Mobile Eddy Covariance Tower
The human dimensions of energy use in buildings: A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Oca, Simona; Hong, Tianzhen; Langevin, Jared
The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.« less
The human dimensions of energy use in buildings: A review
D'Oca, Simona; Hong, Tianzhen; Langevin, Jared
2017-08-19
The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heaney, M.; Polly, B.
2015-04-30
This report presents an analysis of data for residential single-family projects reported by 37 organizations that were awarded federal financial assistance (cooperative agreements or grants) by the U.S. Department of Energy’s Better Buildings Neighborhood Program.1 The report characterizes the energy-efficiency measures installed for single-family residential projects and analyzes energy savings and savings prediction accuracy for measures installed in a subset of those projects.
NASA Astrophysics Data System (ADS)
Toprak, A. Emre; Gülay, F. Gülten; Ruge, Peter
2008-07-01
Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 m×7.80 m = 127.90 m2 with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher than the requirements of the Turkish Earthquake Code while the selected ground conditions represent the same characteristics. The main reason is that the ordinate of the horizontal elastic response spectrum for Eurocode 8 is increased by the soil factor. In TEC'07 force-based linear assessment, the seismic demands at cross-sections are to be checked with residual moment capacities; however, the chord rotations of primary ductile elements must be checked for Eurocode safety verifications. On the other hand, the demand curvatures from linear methods of analysis of Eurocode 8 together with TEC'07 are almost similar.
1. EXTERIOR OVERVIEW OF PLANT 4 RESIDENTIAL COMPLEX SHOWING BUILDING ...
1. EXTERIOR OVERVIEW OF PLANT 4 RESIDENTIAL COMPLEX SHOWING BUILDING 106 AT PHOTO CENTER JUST TO THE RIGHT OF THE PLANT 5 FOREBAY SPILLWAY. VIEW TO WEST - Bishop Creek Hydroelectric System, Plant 4, Worker Cottage, Bishop Creek, Bishop, Inyo County, CA
78 FR 18560 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... approved collection for forms C-700, Private Construction Projects; C-700 (R), Multi-family Residential... private companies or individuals, private multi-family residential buildings, and on building projects... sample basis from federal, state and local agency officials, owners of private nonresidential projects...
Energy efficiency to reduce residential electricity and natural gas use under climate change
Reyna, Janet L.; Chester, Mikhail V.
2017-01-01
Climate change could significantly affect consumer demand for energy in buildings, as changing temperatures may alter heating and cooling loads. Warming climates could also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy efficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41–87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy efficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand. PMID:28504255
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Scope. 435.301 Section 435.301 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.301 Scope. (a) The energy...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Purpose. 435.300 Section 435.300 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.300 Purpose. (a) This subpart...
10 CFR 435.5 - Performance level determination.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Performance level determination. 435.5 Section 435.5 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Purpose. 435.300 Section 435.300 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.300 Purpose. (a) This subpart...
10 CFR 435.305 - Alternative compliance procedure.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Alternative compliance procedure. 435.305 Section 435.305 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.305...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Scope. 435.301 Section 435.301 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.301 Scope. (a) The energy...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Purpose. 435.300 Section 435.300 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Residential Buildings § 435.300 Purpose. (a) This subpart...
10 CFR 435.5 - Performance level determination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Performance level determination. 435.5 Section 435.5 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...
Comprehensive benefits analysis of steel structure modular residence based on the entropy evaluation
NASA Astrophysics Data System (ADS)
Zhang, Xiaoxiao; Wang, Li; Jiang, Pengming
2017-04-01
Steel structure modular residence is the outstanding residential industrialization. It has many advantages, such as the low whole cost, high resource recovery, a high degree of industrialization. This paper compares the comprehensive benefits of steel structural in modular buildings with prefabricated reinforced concrete residential from economic benefits, environmental benefits, social benefits and technical benefits by the method of entropy evaluation. Finally, it is concluded that the comprehensive benefits of steel structural in modular buildings is better than that of prefabricated reinforced concrete residential. The conclusion of this study will provide certain reference significance to the development of steel structural in modular buildings in China.
10 CFR 435.3 - Material incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Material incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...
10 CFR 435.3 - Material incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Material incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...
Design and Implementation of Green Construction Scheme for a High-rise Residential Building Project
NASA Astrophysics Data System (ADS)
Zhou, Yong; Huang, You Zhen
2018-06-01
This paper mainly studies the green construction scheme of a high-rise residential building project. From "four sections one environmental protection", saving material, water saving, energy saving, economical use of land and environmental protection conduct analysis and research. Adopting scientific, advanced, reasonable and economical construction technology measures, implementing green construction method. Promoting energy-saving technologies in buildings, ensuring the sustainable use of resources, Maximum savings of resources and energy, increase energy efficiency, to reduce pollution, reducing the adverse environmental impact of construction activities, ensure construction safety, build sustainable buildings.
Analysis of wallboard containing a phase change material
NASA Astrophysics Data System (ADS)
Tomlinson, J. J.; Heberle, D. P.
Phase change materials (PCMs) used on the interior of buildings hold the promise for improved thermal performance by reducing the energy requirements for space conditioning and by improving thermal comfort by reducing temperature swings inside the building. Efforts are underway to develop a gypsum wallboard containing a hydrocarbon PCM. With a phase change temperature in the room temperature range, the PCM wallboard adds substantially to the thermal mass of the building while serving the same architectural function as conventional wallboard. To determine the thermal and economic performance of this PCM wallboard, the Transient Systems Simulation Program (TRNSYS) was modified to accommodate walls that are covered with PCM plasterboard, and to apportion the direct beam solar radiation to interior surfaces of a building. The modified code was used to simulate the performance of conventional and direct-gain passive solar residential-sized buildings with and without PCM wallboard. Space heating energy savings were determined as a function of PCM wallboard characteristics. Thermal comfort improvements in buildings containing the PCM were qualified in terms of energy savings. The report concludes with a present worth economic analysis of these energy savings and arrives at system costs and economic payback based on current costs of PCMs under study for the wallboard application.
NREL Partners with California to Accelerate Advanced Energy Communities |
, heating, and or cooling Smart energy management systems for residential, commercial and industrial the residences, commercial and industrial buildings. Visit the NREL website to learn about how NREL's efficiency of both residential and commercial buildings, communities, and districts. -Linh Truong Mission
Improving the Accuracy of Software-Based Energy Analysis for Residential Buildings (Presentation)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polly, B.
2011-09-01
This presentation describes the basic components of software-based energy analysis for residential buildings, explores the concepts of 'error' and 'accuracy' when analysis predictions are compared to measured data, and explains how NREL is working to continuously improve the accuracy of energy analysis methods.
The influence of opening windows and doors on the natural ventilation rate of a residential building
Increased building energy efficiency is important in reducing national energy use and greenhouse gas emissions. An analysis of air change rates due to door and window openings in a research test house located in a residential environment are presented. These data inform developme...
NASA Astrophysics Data System (ADS)
Vacca, G.; Pili, D.; Fiorino, D. R.; Pintus, V.
2017-05-01
The presented work is part of the research project, titled "Tecniche murarie tradizionali: conoscenza per la conservazione ed il miglioramento prestazionale" (Traditional building techniques: from knowledge to conservation and performance improvement), with the purpose of studying the building techniques of the 13th-18th centuries in the Sardinia Region (Italy) for their knowledge, conservation, and promotion. The end purpose of the entire study is to improve the performance of the examined structures. In particular, the task of the authors within the research project was to build a WebGIS to manage the data collected during the examination and study phases. This infrastructure was entirely built using Open Source software. The work consisted of designing a database built in PostgreSQL and its spatial extension PostGIS, which allows to store and manage feature geometries and spatial data. The data input is performed via a form built in HTML and PHP. The HTML part is based on Bootstrap, an open tools library for websites and web applications. The implementation of this template used both PHP and Javascript code. The PHP code manages the reading and writing of data to the database, using embedded SQL queries. As of today, we surveyed and archived more than 300 buildings, belonging to three main macro categories: fortification architectures, religious architectures, residential architectures. The masonry samples investigated in relation to the construction techniques are more than 150. The database is published on the Internet as a WebGIS built using the Leaflet Javascript open libraries, which allows creating map sites with background maps and navigation, input and query tools. This too uses an interaction of HTML, Javascript, PHP and SQL code.
NASA Astrophysics Data System (ADS)
Meng, Xuelian
Urban land-use research is a key component in analyzing the interactions between human activities and environmental change. Researchers have conducted many experiments to classify urban or built-up land, forest, water, agriculture, and other land-use and land-cover types. Separating residential land uses from other land uses within urban areas, however, has proven to be surprisingly troublesome. Although high-resolution images have recently become more available for land-use classification, an increase in spatial resolution does not guarantee improved classification accuracy by traditional classifiers due to the increase of class complexity. This research presents an approach to detect and separate residential land uses on a building scale directly from remotely sensed imagery to enhance urban land-use analysis. Specifically, the proposed methodology applies a multi-directional ground filter to generate a bare ground surface from lidar data, then utilizes a morphology-based building detection algorithm to identify buildings from lidar and aerial photographs, and finally separates residential buildings using a supervised C4.5 decision tree analysis based on the seven selected building land-use indicators. Successful execution of this study produces three independent methods, each corresponding to the steps of the methodology: lidar ground filtering, building detection, and building-based object-oriented land-use classification. Furthermore, this research provides a prototype as one of the few early explorations of building-based land-use analysis and successful separation of more than 85% of residential buildings based on an experiment on an 8.25-km2 study site located in Austin, Texas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rice, C. Keith; Shen, Bo; Shrestha, Som S.
This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirementmore » (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28% increase in delivered heating load and an ~52% increase in the estimated heating operating cost over that given in the AHRI directory (AHRI 2014).« less
Baggiani, A; Casini, B; Totaro, M; Aquino, F; Valentini, P; Bruni, B; Porretta, A; Casalini, F; Miccoli, M; Privitera, G
2015-01-01
Despite the increase of community acquired cases of legionellosis in Italy over the last years, the Italian guidelines do not give indications for prevention and control of Legionella in the hot water networks (or centralized conditioning systems) of residential buildings. We performed a survey on eight medium sized apartment buildings in the Pisa district to assess the prevalence of Legionella spp. in the water network and the respondance to drinking water requisites at the point of use, according to the Italian norms. For each building two hot water and three cold water samples (located at water entrance from the aqueduct network into the building pipework, at the exit from pressure autoclave, and at a remote tap) were collected. Legionella was detected in 20% of residential buildings, mostly in those with a central hot water production system. The study highlights a condition of potential risk for susceptible population subgroups and supports the need for measures of risk assessment and control.
Indoor Air Quality of Residential Building Before and After Renovation
NASA Astrophysics Data System (ADS)
Sánka, Imrich; Földváry, Veronika
2017-06-01
This study investigates the impact of energy renovation on the indoor air quality of an apartment building during the heating season. The study was performed in one residential building before and after its renovation. An evaluation of the indoor air quality was performed using objective measurements and a subjective survey. The concentration of CO2 was measured in the bedrooms, and a sampling of the total volatile compounds (TVOC) was performed in the living rooms of the selected apartments. Higher concentrations of CO2 and TVOC were observed in the residential building after its renovation. The concentrations of CO2, and TVOC in some of the cases exceeded the recommended maximum limits, especially after implementing energy-saving measures on the building. The average air exchange rate was visibly higher before the renovation of the building. The current study indicates that large-scale renovations may reduce the quality of an indoor environment in many apartments, especially in the winter season.
NASA Astrophysics Data System (ADS)
Cole, H. E.; Fuller, R. E.
1980-09-01
Four of the major models used by DOE for energy conservation analyses in the residential and commercial building sectors are reviewed and critically analyzed to determine how these models can serve as tools for DOE and its Conservation Policy Office in evaluating and quantifying their policy and program requirements. The most effective role for each model in addressing future issues of buildings energy conservation policy and analysis is assessed. The four models covered are: Oak Ridge Residential Energy Model; Micro Analysis of Transfers to Households/Comprehensive Human Resources Data System (MATH/CHRDS) Model; Oak Ridge Commercial Energy Model; and Brookhaven Buildings Energy Conservation Optimization Model (BECOM).
NASA Astrophysics Data System (ADS)
Dong, J. Y.; Cheng, W.; Ma, C. P.; Xin, L. S.; Tan, Y. T.
2017-06-01
In order to study the issue of rural residential energy consumption in cold regions of China, modeled an architecture prototype based on BIM platform according to the affecting factors of rural residential thermal environment, and imported the virtual model which contains building information into energy analysis tools and chose the appropriate building orientation. By analyzing the energy consumption of the residential buildings with different enclosure structure forms, we designed the optimal energy-saving residence form. There is a certain application value of this method for researching the energy consumption and energy-saving design for the rural residence in cold regions of China.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
By working with builder partners on test homes, researchers from the U.S. Department of Energy’s Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 “Performance House” was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies usedmore » in the “Performance House” were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
By working with builder partners on test homes, researchers from the U.S. Department of Energy's Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies usedmore » in the "Performance House" were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).« less
The influence of opening windows and doors on the natural ventilation rate of a residential building
An analysis of air exchange rates due to intentional window and door openings in a research test house located in a residential environment is presented. These data inform the development of ventilation rate control strategies as building envelopes are tightened to improve the e...
Wiedenhofer, Dominik; Steinberger, Julia K; Eisenmenger, Nina; Haas, Willi
2015-08-01
Material stocks are an important part of the social metabolism. Owing to long service lifetimes of stocks, they not only shape resource flows during construction, but also during use, maintenance, and at the end of their useful lifetime. This makes them an important topic for sustainable development. In this work, a model of stocks and flows for nonmetallic minerals in residential buildings, roads, and railways in the EU25, from 2004 to 2009 is presented. The changing material composition of the stock is modeled using a typology of 72 residential buildings, four road and two railway types, throughout the EU25. This allows for estimating the amounts of materials in in-use stocks of residential buildings and transportation networks, as well as input and output flows. We compare the magnitude of material demands for expansion versus those for maintenance of existing stock. Then, recycling potentials are quantitatively explored by comparing the magnitude of estimated input, waste, and recycling flows from 2004 to 2009 and in a business-as-usual scenario for 2020. Thereby, we assess the potential impacts of the European Waste Framework Directive, which strives for a significant increase in recycling. We find that in the EU25, consisting of highly industrialized countries, a large share of material inputs are directed at maintaining existing stocks. Proper management of existing transportation networks and residential buildings is therefore crucial for the future size of flows of nonmetallic minerals.
Steinberger, Julia K.; Eisenmenger, Nina; Haas, Willi
2015-01-01
Summary Material stocks are an important part of the social metabolism. Owing to long service lifetimes of stocks, they not only shape resource flows during construction, but also during use, maintenance, and at the end of their useful lifetime. This makes them an important topic for sustainable development. In this work, a model of stocks and flows for nonmetallic minerals in residential buildings, roads, and railways in the EU25, from 2004 to 2009 is presented. The changing material composition of the stock is modeled using a typology of 72 residential buildings, four road and two railway types, throughout the EU25. This allows for estimating the amounts of materials in in‐use stocks of residential buildings and transportation networks, as well as input and output flows. We compare the magnitude of material demands for expansion versus those for maintenance of existing stock. Then, recycling potentials are quantitatively explored by comparing the magnitude of estimated input, waste, and recycling flows from 2004 to 2009 and in a business‐as‐usual scenario for 2020. Thereby, we assess the potential impacts of the European Waste Framework Directive, which strives for a significant increase in recycling. We find that in the EU25, consisting of highly industrialized countries, a large share of material inputs are directed at maintaining existing stocks. Proper management of existing transportation networks and residential buildings is therefore crucial for the future size of flows of nonmetallic minerals. PMID:27524878
Patton, Allison P.; Calderon, Leonardo; Xiong, Youyou; Wang, Zuocheng; Senick, Jennifer; Sorensen Allacci, MaryAnn; Plotnik, Deborah; Wener, Richard; Andrews, Clinton J.; Krogmann, Uta; Mainelis, Gediminas
2016-01-01
There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m3) than in Building L (37 µg/m3); I/O was higher in Building E (1.3–2.0) than in Building L (0.5–0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents’ exposure to PM in residential green buildings. PMID:26805862
Patton, Allison P; Calderon, Leonardo; Xiong, Youyou; Wang, Zuocheng; Senick, Jennifer; Sorensen Allacci, MaryAnn; Plotnik, Deborah; Wener, Richard; Andrews, Clinton J; Krogmann, Uta; Mainelis, Gediminas
2016-01-20
There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m³) than in Building L (37 µg/m³); I/O was higher in Building E (1.3-2.0) than in Building L (0.5-0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents' exposure to PM in residential green buildings.
Michikawa, Takehiro; Morokuma, Seiichi; Nitta, Hiroshi; Kato, Kiyoko; Yamazaki, Shin
2017-06-13
Numerous earlier studies examining the association of air pollution with maternal and foetal health estimated maternal exposure to air pollutants based on the women's residential addresses. However, residential addresses, which are personally identifiable information, are not always obtainable. Since a majority of pregnant women reside near their delivery hospitals, the concentrations of air pollutants at the respective delivery hospitals may be surrogate markers of pollutant exposure at home. We compared air pollutant concentrations measured at the nearest monitoring station to Kyushu University Hospital with those measured at the closest monitoring stations to the respective residential postal code regions of pregnant women in Fukuoka. Aggregated postal code data for the home addresses of pregnant women who delivered at Kyushu University Hospital in 2014 was obtained from Kyushu University Hospital. For each of the study's 695 women who resided in Fukuoka Prefecture, we assigned pollutant concentrations measured at the nearest monitoring station to Kyushu University Hospital and pollutant concentrations measured at the nearest monitoring station to their respective residential postal code regions. Among the 695 women, 584 (84.0%) resided in the proximity of the nearest monitoring station to hospital or one of the four other stations (as the nearest stations to their respective residential postal code region) in Fukuoka city. Pearson's correlation for daily mean concentrations among the monitoring stations in Fukuoka city was strong for fine particulate matter (PM 2.5 ), suspended particulate matter (SPM), and photochemical oxidants (Ox) (coefficients ≥0.9), but moderate for coarse particulate matter (the result of subtracting the PM 2.5 from the SPM concentrations), nitrogen dioxide, and sulphur dioxide. Hospital-based and residence-based concentrations of PM 2.5 , SPM, and Ox were comparable. For PM 2.5 , SPM, and Ox, exposure estimation based on the delivery hospital is likely to approximate that based on the home of pregnant women.
NASA Astrophysics Data System (ADS)
Rovithis, Emmanouil; Kirtas, Emmanouil; Marini, Eleftheria; Bliziotis, Dimitris; Maltezos, Evangelos; Pitilakis, Dimitris; Makra, Konstantia; Savvaidis, Alexandros
2016-08-01
Airborne LiDAR monitoring integrated with field data is employed to assess the fundamental period and the seismic loading of structures composing an urban area under prescribed earthquake scenarios. Α piecewise work-flow is adopted by combining geometrical data of the building stock derived from a LiDAR-based 3D city model, structural data from in-situ inspections on representative city blocks and results of soil response analyses. The procedure is implemented in the residential area of Kalochori, (west of Thessaloniki in Northern Greece). Special attention is paid to the in-situ inspection of the building stock in order to discriminate recordings between actual buildings and man-made constructions that do not conform to seismic design codes and to acquire additional building stock data on structural materials, typologies and number of stories which is not feasible by the LiDAR process. The processed LiDAR and field data are employed to compute the fundamental period of each building by means of code-defined formulas. Knowledge of soil conditions in the Kalochoti area allows for soil response analyses to obtain free-field at ground surface under earthquake scenarios with varying return period. Upon combining the computed vibrational characteristics of the structures with the free-field response spectra, the seismic loading imposed on the structures of the urban area under investigation is derived for each one of the prescribed seismic motions. Results are presented in GIS environment in the form of spatially distributed spectral accelerations with direct implications in seismic vulnerability studies of an urban area.
The Advancement of Cool Roof Standards in China from 2010 to 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge, Jing; Levinson, Ronnen M.
Since the initiation of the U.S.-China Clean Energy Research Center-Building Energy Efficiency (CERC-BEE) cool roof research collaboration between the Lawrence Berkeley National Laboratory Heat Island Group and Chinese institutions in 2010, new cool surface credits (insulation trade- offs) have been adopted in Chinese building energy efficiency standards, industry standards, and green building standards. JGJ 75-2012: Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Warm Winter Zone became the first national level standard to provide cool surface credits. GB/T 50378-2014: Assessment Standard for Green Building is the first national level green building standard that offers points formore » heat island mitigation. JGJ/T 359-2015: Technical Specification for Application of Architectural Reflective Thermal Insulation Coating is the first industry standard that offers cool coating credits for both public and residential buildings in all hot-summer climates (Hot Summer/Cold Winter, Hot Summer/Warm Winter). As of December 2015, eight provinces or municipalities in hot-summer regions have credited cool surfaces credits in their residential and/or public building design standards; five other provinces or municipalities in hot-summer regions recommend, but do not credit, the use of cool surfaces in their building design standards. Cool surfaces could be further advanced in China by including cool roof credits for residential and public building energy efficiency standards in all hot-summer regions; developing a standardized process for natural exposure and aged-property rating of cool roofing products; and adapting the U.S.-developed laboratory aging process for roofing materials to replicate solar reflectance changes induced by natural exposure in China.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toprak, A. Emre; Guelay, F. Guelten; Ruge, Peter
2008-07-08
Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performedmore » on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 mx7.80 m = 127.90 m{sup 2} with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher than the requirements of the Turkish Earthquake Code while the selected ground conditions represent the same characteristics. The main reason is that the ordinate of the horizontal elastic response spectrum for Eurocode 8 is increased by the soil factor. In TEC'07 force-based linear assessment, the seismic demands at cross-sections are to be checked with residual moment capacities; however, the chord rotations of primary ductile elements must be checked for Eurocode safety verifications. On the other hand, the demand curvatures from linear methods of analysis of Eurocode 8 together with TEC'07 are almost similar.« less
Thermal Impact of Fasteners in High-Performance Wood-Framed Walls: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christensen, D.
2011-01-01
Buildings are heavy consumers of energy, and residential building design is rapidly addressing topics to maximize energy conservation en route to net-zero energy consumption. Annual energy analysis of a building informs the choice among disparate energy measures, for cost, durability, occupant comfort, and whole-house energy use. Physics-based and empirical models of elements of a building are used in such analyses. High-performance wood-framed walls enable builders to construct homes that use much less than 40% of the energy consumed by similar homes built to minimum code. Modeling for these walls has considered physical features such as framing factor, insulation and framingmore » properties, roughness and convective effects, and air leakage. The thermal effects of fasteners used to construct these walls have not been fully evaluated, even though their thermal conductivity is orders of magnitudes higher than that of other building materials. Drywall screws and siding nails are considered in this finite element thermal conductivity analysis of wall sections that represent wood-framed walls that are often used in high-performance homes. Nails and screws reduce even the best walls' insulating performance by approximately 3% and become increasingly significant as the framing factor increases.« less
NASA Astrophysics Data System (ADS)
Źróbek-Różańska, Alina; Zysk, Elżbieta; Źróbek, Sabina
2017-10-01
Poland has a turbulent and rich history. Partitions, wars, a centrally planned economy of the socialist era and the rapid transition to a market economy left visible marks on the Polish landscape. The changes that took place in the 20th century and the early 21st century have vastly influenced the country’s architecture. Residential buildings in rural suburbs bear witness to turbulent historical events and change processes. This study analyzed residential buildings in two villages situated in the historical district of Warmia (north-eastern Poland) which is now a part of the Region of Warmia and Mazury. The results of the observations were used to review the social, economic, legal and planning factors that influenced residential architecture between 1900 and 2017. The traditional layout of Warmian villages is well preserved in the analyzed locations where pre-war architectural design mingles with buildings erected in the socialist era when construction materials were scarce. Many buildings in the surveyed villages are reminiscent of collective farms, the prescribed architectural style of the 1970s as well as the stylistic diversity of the early transformation period when customized building plans and construction materials became available. The local landscape also features buildings erected in successive decades which brought a significant increase in the price of land and maintenance costs.
Do We Really Know how Much it Costs to Construct High Performance Buildings?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Livingston, Olga V.; Dillon, Heather E.; Halverson, Mark A.
2012-08-31
Understanding the cost of energy efficient construction is critical to decision makers in building design, code development, and energy analysis. How much does it cost to upgrade from R-13 to R-19 in a building wall? How much do low-e windows really cost? Can we put a dollar figure on commissioning? Answers to these questions have a fuzzy nature, based on educated guesses and industry lore. The response depends on location, perspective, bulk buying, and hand waving. This paper explores the development of a web tool intended to serve as a publicly available repository of building component costs. In 2011 themore » U.S. Department of Energy (DOE) funded the launch of a web tool called the Building Component Cost Community (BC3), dedicated to publishing building component costs from documented sources, actively gathering verifiable cost data from the users, and collecting feedback from a wide range of participants on the quality of the posted cost data. The updated BC3 database, available at http://bc3.pnnl.gov, went live on April 30, 2012. BC3 serves as the ultimate source of the energy-related component costs for DOE’s residential code development activities, including cost-effectiveness analyses. The paper discusses BC3 objectives, structure, functionality and the current content of the database. It aims to facilitate a dialog about the lack of verifiable transparent cost data, as well as introduce a web tool that helps to address the problem. The questions posed above will also be addressed by this paper, but they have to be resolved by the user community by providing feedback and cost data to the BC3 database, thus increasing transparency and removing information asymmetry.« less
Lead in Drinking Water in Schools and Non-Residential Buildings.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC.
This manual demonstrates how drinking water in schools and non-residential buildings can be tested for lead and how contamination problems can be corrected when found. The manual also provides background information concerning the sources and health effects of lead, how lead gets into drinking water, how lead in drinking water is regulated, and…
ERIC Educational Resources Information Center
Energy Research and Development Administration, Washington, DC. Div. of Solar Energy.
Three volumes present brief abstracts of projects funded by the Energy Research and Development Administration (ERDA) and conducted under the National Program for Solar Heating and Cooling of Buildings through July 1976. The overall federal program includes demonstrations of heating and/or combined cooling for residential and commercial buildings…
NASA Astrophysics Data System (ADS)
Kilnarová, Pavla; Wittmann, Maxmilian
2017-12-01
The characteristics of open spaces between residential buildings have, as authors suppose, an impact on the sustainable development of urban areas. Spatial arrangement and accessibility of these spaces, the type and height of surrounding buildings, the quantity and character of greenery, and many more characteristics influence the quality of environment, and the quality of life of local residents. These and further characteristics of the open spaces between residential buildings influence the ecological stability of the area, its hygienic qualities, the intensity and way of using by various social groups, and also the prices of real estates. These qualities indicate the environmental, social and economic sustainability of the urban area. The proposed research methodology assessed specific indicators of sustainability within a range from 0 to 10 points. 5 points correspond to the general standard in the area, 0 points indicate degradation, and 10 points indicate the highest contribution to sustainable development. Observation methods, questionnaire survey, statistical analyses, and methods of measurement were used to determine the values of the given indicators. The paper analyses the impact of the open spaces between residential buildings on sustainability via the case studies performed in the Central European cities of Brno, Czech Republic and Vienna, Austria. Two forms of residential urban structures in the City of Brno in the Czech Republic were selected for the analysis: the closed courtyards in the urban block from the 19th century and the open spaces in the housing estates constructed under socialism in the 20th century. The question is, if the different forms of spaces between residential buildings influence the sustainability of urban area and satisfaction of inhabitants in different ways. A complementary case study in Vienna indicates that inhabitants of a housing estate in Vienna, as well as inhabitants of housing estates in Brno, highly appreciate the meaning of large green open spaces between buildings. The paper presents results of basic research. The results indicate that the sustainability of open housing estate forms is higher than the authors expected.
NASA Astrophysics Data System (ADS)
Guo, Fei
The buildings sector is the largest energy-consuming sector in the world. Residential buildings consume about three-quarters of the final energy in the buildings sector. Promoting residential energy savings is in consequence critical for addressing many energy-use-related environmental challenges, such as climate change and air pollution. Given China's robust economic growth and fast urbanization, it is now a critical time to develop policy interventions on residential energy use in the nation. With this as a background, this dissertation explores effective policy intervention opportunities in southern China through analyzing the residential energy-saving potential, using the city of Xiamen as a case study. Four types of residential energy-saving potential are analyzed: technical potential, economic potential, maximum achievable potential (MAP), and possible achievable potential (PAP). Of these, the first two types are characterized as static theoretical evaluation, while the last two represent dynamic evaluation within a certain time horizon. The achievable potential analyses are rarely seen in existing literature. The analytical results reveal that there exists a significant technical potential for residential energy savings of about 20.9-24.9% in the city of Xiamen. Of the technical potential, about two-thirds to four-fifths are cost-effective from the government or society perspective. The cost-effectiveness is evaluated by comparing the "Levelized Cost of Conserved Energy (LCOCE)" of available advanced technical measures with the "Actual Cost" of conserved energy. The "Actual Cost" of energy is defined by adding the environmental externalities costs and hidden government subsidies over the retail prices of energy. The achievable potential analyses are particularly based on two key realistic factors: 1) the gradual ramping-up adoption process of advanced technical measures; and 2) individuals' adoption-decision making on them. For implementing the achievable potential analyses in Xiamen, a residential energy consumption (REC) projection model specifically tailored for southern China is developed. This computational model builds on the Kastovich (1982) adoption-decision theory and the general logic used in the U.S. EIA's (2003) National Energy Modeling System (NEMS). Base on this projection model, Xiamen's REC from the base year 2011 to 2020 is projected. This model can be used as a policy analysis tool to quantitatively evaluate the real-world impact of diverse policy incentives on residential energy use in southern China. The projection results show that the MAP of residential energy savings in Xiamen will be about only 8.3-8.4% in 2020 from a business-as-usual projection. Ten current appropriate and feasible policy interventions are evaluated for analyzing the PAP in Xiamen, which reveals that only about one-fourth to one-half of Xiamen's MAP will possibly be achieved in 2020. Based on the potential analysis for the Xiamen case, a discussion on promoting energy-saving incentive policies for the residential buildings in southern China is given. It suggests that more new, innovative and market-based policies need to be introduced in China in order to realize larger achievable potential for residential energy savings.
Bracken, M B; Belanger, K; Hellenbrand, K; Addesso, K; Patel, S; Triche, E; Leaderer, B P
1998-09-01
The home wiring code is the most widely used metric for studies of residential electromagnetic field (EMF) exposure and health effects. Despite the fact that wiring code often shows stronger correlations with disease outcome than more direct EMF home assessments, little is known about potential confounders of the wiring code association. In a study carried out in southern Connecticut in 1988-1991, the authors used strict and widely used criteria to assess the wiring codes of 3,259 homes in which respondents lived. They also collected other home characteristics from the tax assessor's office, estimated traffic density around the home from state data, and interviewed each subject (2,967 mothers of reproductive age) for personal characteristics. Women who lived in very high current configuration wiring coded homes were more likely to be in manual jobs and their homes were older (built before 1949, odds ratio (OR) = 73.24, 95% confidence interval (CI) 29.53-181.65) and had lower assessed value and higher traffic densities (highest density quartile, OR = 3.99, 95% CI 1.17-13.62). Because some of these variables have themselves been associated with health outcomes, the possibility of confounding of the wiring code associations must be rigorously evaluated in future EMF research.
NASA Astrophysics Data System (ADS)
Nurdiani, N.
2018-03-01
Low cost flats in Jakarta – Indonesia is provided by the government for low-income people in urban areas, in line with the program to redevelop or renew slum areas. Low cost flat is built with the minimum standard of building materials. The purpose of this study is to know efforts of the occupants to change of building materials at residential unit of low cost flats. The research was conducted by descriptive method at four of low cost housing in Jakarta: Rusuna Bendungan Hilir 1, Rusuna Tambora IIIA, Rusuna Bidara Cina, and Rusuna Sukapura. The results showed that physical changes which happened in low cost flats are aesthetic (residence paint color change), or improvement of physical quality of residential unit (change of building material), become dominant aspects done by residents in four rusuna.
Zhang, Pei-Feng; Hu, Yuan-Man; Xiong, Zai-Ping; Liu, Miao
2011-02-01
Based on the 1:10000 aerial photo in 1997 and the three QuickBird images in 2002, 2005, and 2008, and by using Barista software and GIS and RS techniques, the three-dimensional information of the residential community in Tiexi District of Shenyang was extracted, and the variation pattern of the three-dimensional landscape in the district during its reconstruction in 1997-2008 and related affecting factors were analyzed with the indices, ie. road density, greening rate, average building height, building height standard deviation, building coverage rate, floor area rate, building shape coefficient, population density, and per capita GDP. The results showed that in 1997-2008, the building area for industry decreased, that for commerce and other public affairs increased, and the area for residents, education, and medical cares basically remained stable. The building number, building coverage rate, and building shape coefficient decreased, while the floor area rate, average building height, height standard deviation, road density, and greening rate increased. Within the limited space of residential community, the containing capacity of population and economic activity increased, and the environment quality also improved to some extent. The variation degree of average building height increased, but the building energy consumption decreased. Population growth and economic development had positive correlations with floor area rate, road density, and greening rate, but negative correlation with building coverage rate.
the energy efficiency of both residential and commercial buildings, and to accelerate the integration Commercial Buildings team focuses on providing large institutional and private sector commercial building
Achieving Challenge Home in Affordable Housing in the Hot-Humid Climate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beal, D.; McIlvaine, J.; Winter, B.
2014-08-01
The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region. A further objective of thismore » research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale.« less
Achieving Challenge Home in Affordable Housing in the Hot-Humid Climate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beal, D.; McIlvaine, J.; Winter, B.
2014-08-01
The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process (now Zero Energy Ready Home) in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region.more » A further objective of this research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buechler, Elizabeth D.; Pallin, Simon B.; Boudreaux, Philip R.
The indoor air temperature and relative humidity in residential buildings significantly affect material moisture durability, HVAC system performance, and occupant comfort. Therefore, indoor climate data is generally required to define boundary conditions in numerical models that evaluate envelope durability and equipment performance. However, indoor climate data obtained from field studies is influenced by weather, occupant behavior and internal loads, and is generally unrepresentative of the residential building stock. Likewise, whole-building simulation models typically neglect stochastic variables and yield deterministic results that are applicable to only a single home in a specific climate. The
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Automated Residential Energy Standard (ARES) program is designed to identify levels of thermal integrity (e.g., insulation levels, glazing layers, equipment efficiencies, etc.) that are cost effective for typical residential structures and to create a residential energy standard based on these levels. This document contains technical background the explains the data and the algorithms used by the program.
Sampling design for the 1980 commercial and multifamily residential building survey
NASA Astrophysics Data System (ADS)
Bowen, W. M.; Olsen, A. R.; Nieves, A. L.
1981-06-01
The extent to which new building design practices comply with the proposed 1980 energy budget levels for commercial and multifamily residential building designs (DEB-80) can be assessed by: (1) identifying small number of building types which account for the majority of commercial buildings constructed in the U.S.A.; (2) conducting a separate survey for each building type; and (3) including only buildings designed during 1980. For each building, the design energy consumption (DEC-80) will be determined by the DOE2.1 computer program. The quantity X = (DEC-80 - DEB-80). These X quantities can then be used to compute sample statistics. Inferences about nationwide compliance with DEB-80 may then be made for each building type. Details of the population, sampling frame, stratification, sample size, and implementation of the sampling plan are provided.
Analysis of wallboard containing a phase change material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tomlinson, J.J.; Heberle, D.P.
1990-01-01
Phase change materials (PCMs) used on the interior of buildings hold the promise for improved thermal performance by reducing the energy requirements for space conditioning and by improving thermal comfort by reducing temperature swings inside the building. Efforts are underway to develop a gypsum wallboard containing a hydrocarbon PCM. With a phase change temperature in the room temperature range, the PCM wallboard adds substantially to the thermal mass of the building while serving the same architectural function as conventional wallboard. To determine the thermal and economic performance of this PCM wallboard, the Transient Systems Simulation Program (TRNSYS) was modified tomore » accommodate walls that are covered with PCM plasterboard, nd to apportion the direct beam solar radiation to interior surfaces of a building. The modified code was used to simulate the performance of conventional and direct-gain passive solar residential-sized buildings with and without PCM wallboard. Space heating energy savings were determined as a function of PCM wallboard characteristics. Thermal comfort improvements in buildings containing the PCM were qualified in terms of energy savings. The report concludes with a present worth economic analysis of these energy savings and arrives at system costs and economic payback based on current costs of PCMs under study for the wallboard application. 5 refs., 4 figs., 4 tabs.« less
Residential Demand Module - NEMS Documentation
2017-01-01
Model Documentation - Documents the objectives, analytical approach, and development of the National Energy Modeling System (NEMS) Residential Sector Demand Module. The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, and FORTRAN source code.
Plascak, Jesse J.; Molina, Yamile; Wu-Georges, Samantha; Idris, Ayah; Thompson, Beti
2016-01-01
The relationship between Latino residential segregation and self-rated health (SRH) is unclear, but might be partially affected by social capital. We investigated the association between Latino residential segregation and SRH while also examining the roles of various social capital measures. Washington State Behavioral Risk Factor Surveillance System (2012–2014) and U.S. Census data were linked by zip code and zip code tabulation area. Multilevel logistic regression models were used to estimate odds of good or better SRH by Latino residential segregation, measured by the Gini coefficient, and controlling for sociodemographic, acculturation and social capital measures of neighborhood ties, collective socialization of children, and social control. The Latino residential segregation – SRH relationship was convex, or ‘U’-shaped, such that increases in segregation among Latinos residing in lower segregation areas was associated with lower SRH while increases in segregation among Latinos residing in higher segregation areas was associated with higher SRH. The social capital measures were independently associated with SRH but had little effect on the relationship between Latino residential segregation and SRH. A convex relationship between Latino residential segregation and SRH could explain mixed findings of previous studies. Although important for SRH, social capital measures of neighborhood ties, collective socialization of children, and social control might not account for the relationship between Latino residential segregation and SRH. PMID:27173739
Plascak, Jesse J; Molina, Yamile; Wu-Georges, Samantha; Idris, Ayah; Thompson, Beti
2016-06-01
The relationship between Latino residential segregation and self-rated health (SRH) is unclear, but might be partially affected by social capital. We investigated the association between Latino residential segregation and SRH while also examining the roles of various social capital measures. Washington State Behavioral Risk Factor Surveillance System (2012-2014) and U.S. Census data were linked by zip code and zip code tabulation area. Multilevel logistic regression models were used to estimate odds of good or better SRH by Latino residential segregation, measured by the Gini coefficient, and controlling for sociodemographic, acculturation and social capital measures of neighborhood ties, collective socialization of children, and social control. The Latino residential segregation - SRH relationship was convex, or 'U'-shaped, such that increases in segregation among Latinos residing in lower segregation areas was associated with lower SRH while increases in segregation among Latinos residing in higher segregation areas was associated with higher SRH. The social capital measures were independently associated with SRH but had little effect on the relationship between Latino residential segregation and SRH. A convex relationship between Latino residential segregation and SRH could explain mixed findings of previous studies. Although important for SRH, social capital measures of neighborhood ties, collective socialization of children, and social control might not account for the relationship between Latino residential segregation and SRH. Copyright © 2016 Elsevier Ltd. All rights reserved.
Employment and residential characteristics in relation to automated external defibrillator locations
Griffis, Heather M.; Band, Roger A; Ruther, Matthew; Harhay, Michael; Asch, David A.; Hershey, John C.; Hill, Shawndra; Nadkarni, Lindsay; Kilaru, Austin; Branas, Charles C.; Shofer, Frances; Nichol, Graham; Becker, Lance B.; Merchant, Raina M.
2015-01-01
Background Survival from out-of-hospital cardiac arrest (OHCA) is generally poor and varies by geography. Variability in automated external defibrillator (AED) locations may be a contributing factor. To inform optimal placement of AEDs, we investigated AED access in a major US city relative to demographic and employment characteristics. Methods and Results This was a retrospective analysis of a Philadelphia AED registry (2,559 total AEDs). The 2010 US Census and the Local Employment Dynamics (LED) database by ZIP code was used. AED access was calculated as the weighted areal percentage of each ZIP code covered by a 400 meter radius around each AED. Of 47 ZIP codes, only 9%(4) were high AED service areas. In 26%(12) of ZIP codes, less than 35% of the area was covered by AED service areas. Higher AED access ZIP codes were more likely to have a moderately populated residential area (p=0.032), higher median household income (p=0.006), and higher paying jobs (p=008). Conclusions The locations of AEDs vary across specific ZIP codes; select residential and employment characteristics explain some variation. Further work on evaluating OHCA locations, AED use and availability, and OHCA outcomes could inform AED placement policies. Optimizing the placement of AEDs through this work may help to increase survival. PMID:26856232
External built residential environment characteristics that affect mental health of adults.
Ochodo, Charles; Ndetei, D M; Moturi, W N; Otieno, J O
2014-10-01
External built residential environment characteristics include aspects of building design such as types of walls, doors and windows, green spaces, density of houses per unit area, and waste disposal facilities. Neighborhoods that are characterized by poor quality external built environment can contribute to psychosocial stress and increase the likelihood of mental health disorders. This study investigated the relationship between characteristics of external built residential environment and mental health disorders in selected residences of Nakuru Municipality, Kenya. External built residential environment characteristics were investigated for 544 residents living in different residential areas that were categorized by their socioeconomic status. Medically validated interview schedules were used to determine mental health of residents in the respective neighborhoods. The relationship between characteristics of the external built residential environment and mental health of residents was determined by multivariable logistic regression analyses and chi-square tests. The results show that walling materials used on buildings, density of dwelling units, state of street lighting, types of doors, states of roofs, and states of windows are some built external residential environment characteristics that affect mental health of adult males and females. Urban residential areas that are characterized by poor quality external built environment substantially expose the population to daily stressors and inconveniences that increase the likelihood of developing mental health disorders.
ERIC Educational Resources Information Center
Energy Research and Development Administration, Washington, DC. Div. of Solar Energy.
This pamphlet offers a preview of information services available from Solcost, a research and development project. The first section explains that Solcost calculates system and costs performance for solar heated and cooled new and retrofit constructions, such as residential buildings and single zone commercial buildings. For a typical analysis,…
View southwest along Brown Road showing residential and commercial buildings ...
View southwest along Brown Road showing residential and commercial buildings on the north and south sides of the road - Brooklyn Green, North Green, South Green, & West Green, parts of Brown Road, Canterbury Road (Route 169), Hartford Road (Route 6), Hyde Road, Pomfret Road (Route 169), Prince Hill Road, Providence Road (Route 6), Wauregan Road (Routes 169 & 205), & Wolf Den Road, Brooklyn, Windham County, CT
Criteria of Architectural Composition Design in Residential Courtyards
NASA Astrophysics Data System (ADS)
Ziemeļniece, Aija; Īle, Una
2017-10-01
The totalitarian times of the 50s-80s of the 20th century have brought the building of high-rise residential blocks in Latvian cities, characterized by an uninteresting solution of standard buildings and the alien scale which does not meet the regional features. During the above period, areas of the residential courtyards have not been addressed. The conclusion of the research is that today the courtyards of the high-rise residential houses have become a stagnant, functionally irrelevant area that forms a depressing nature of the outdoor living space. The uncharted area of courtyards is not being used fully which highlights a wide range of issues that applies to car parks, recreation areas, and the green areas. With the development of the urban infrastructure, the creation of high-rise parking facilities and separate car parks are insufficiently addressed. Consequently, the implementation of improvements in courtyards of high-rise residential houses is not possible if the above issue on the removal of the car load from courtyards is not solved. Many building districts are characterized by the same compositional, architectural-spatial structure which even more influences and causes discomfort in these areas to stay. In recent years, the solution to the above issue is sought by the municipal authorities of Latvia to create a new courtyard zoning. It applies to the project development and construction works. In the research, courtyards of the city of Jelgava are analysed and evaluated which from the qualitative point of view demonstrates and is a vivid example where the issues of the research are readable. The city of Jelgava, located 45 km away from Riga, is an expressed satellite city and serves for the agglomeration of Riga as a huge high-rise residential district. Consequently, the research includes separate courtyards of high-rise residential buildings of the city of Jelgava and their study is carried out from the point of view of the architectural composition and the functional point of view of courtyards.
NASA Astrophysics Data System (ADS)
Denysenko, Artur
After collapse of the Soviet Union, Ukraine inherited vast and inefficient infrastructure. Combination of historical lack of transparency, decades without reforms, chronical underinvestment and harmful cross-subsidization resulted in accumulation of energy problems, which possess significant threat to economic prosperity and national security. High energy intensity leads to excessive use of energy and heavy reliance on energy import to meet domestic demand. Energy import, in turn, results in high account balance deficit and heavy burden on the state finances. A residential sector, which accounts for one third of energy consumption and is the highest consumer of natural gas, is particularly challenging to reform. This thesis explores energy consumption of the residential sector of Ukraine. Using energy decomposition method, recent changes in energy use is analyzed. Energy intensity of space heating in the residential sector of Ukraine is compared with selected EU member states with similar climates. Energy efficiency potential is evaluated for whole residential sector in general and for multistory apartment buildings connected to the district heating in particular. Specifically, investments in thermal modernization of multistory residential buildings will result in almost 45TWh, or 3.81 Mtoe, of annual savings. Required investments for deep energy retrofit of multistory buildings is estimated as much as $19 billion in 2015 prices. Experience of energy subsidy reforms as well as lessons from energy retrofit policy from selected countries is analyzed. Policy recommendations to turn energy subsidies into investments in deep energy retrofit of residential sector of Ukraine are suggested. Regional dimension of existing energy subsidies and capital subsidies required for energy retrofit is presented.
ERIC Educational Resources Information Center
Howley, Caitlin; Hambrick, Kimberly
2011-01-01
Building on recent research, ICF sought to explore how socioeconomic status and attachment to place influence rural youths' educational and residential preferences across a wider geographic region. Our research questions included: What are rural high school students' educational and residential plans? And what factors influence rural youths' plans…
The Marriage of Residential Energy Codes and Rating Systems: Conflict Resolution or Just Conflict?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, Zachary T.; Mendon, Vrushali V.
2014-08-21
After three decades of coexistence at a distance, model residential energy codes and residential energy rating systems have come together in the 2015 International Energy Conservation Code. At the October, 2013, International Code Council’s Public Comment Hearing, a new compliance path based on an Energy Rating Index was added to the IECC. Although not specifically named in the code, RESNET’s HERS rating system is the likely candidate Index for most jurisdictions. While HERS has been a mainstay in various beyond-code programs for many years, its direct incorporation into the most popular model energy code raises questions about the equivalence ofmore » a HERS-based compliance path and the traditional IECC performance compliance path, especially because the two approaches use different efficiency metrics, are governed by different simulation rules, and have different scopes with regard to energy impacting house features. A detailed simulation analysis of more than 15,000 house configurations reveals a very large range of HERS Index values that achieve equivalence with the IECC’s performance path. This paper summarizes the results of that analysis and evaluates those results against the specific Energy Rating Index values required by the 2015 IECC. Based on the home characteristics most likely to result in disparities between HERS-based compliance and performance path compliance, potential impacts on the compliance process, state and local adoption of the new code, energy efficiency in the next generation of homes subject to this new code, and future evolution of model code formats are discussed.« less
World Energy Projection System Plus Model Documentation: Residential Module
2016-01-01
This report documents the objectives, analytical approach and development of the World Energy Projection System Plus (WEPS ) Residential Model. It also catalogues and describes critical assumptions, computational methodology, parameter estimation techniques, and model source code.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dillon, Heather E.; Antonopoulos, Chrissi A.; Solana, Amy E.
As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density permore » unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft{sup 2} of roof area or 0.5 W/ft{sup 2} of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft{sup 2} of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.« less
Radon in earth-sheltered structures
Landa, E.R.
1984-01-01
Radon concentration in the indoor air of six residential and three non-residential earth-sheltered buildings in eastern Colorado was monitored quarterly over a nine-month period using passive, integrating detectors. Average radon concentrations during the three-month sampling periods ranged from about 1 to 9 pCi/L, although one building, a poorly ventilated storage bunker, had concentrations as high as 39 pCi/L. These radon concentrations are somewhat greater than those typically reported for conventional buildings (around 1 pCi/L); but they are of the same order of magnitude as radon concentrations reported for energy-efficient buildings which are not earth-sheltered. ?? 1984.
NASA Astrophysics Data System (ADS)
Gens, Alexandra; Hurley, J. Fintan; Tuomisto, Jouni T.; Friedrich, Rainer
2014-02-01
The insulation of residential buildings affects human exposure to fine particles. According to current EU guidelines, insulation is regulated for energy saving reasons. As buildings become tighter, the air exchange rate is reduced and, thus, the indoor concentration of pollutants is increased if there are significant indoor sources. While usually the effects of heat insulation and increase of the air-tightness of buildings on greenhouse gas emissions are highlighted, the negative impacts on human health due to higher indoor concentrations are not addressed. Thus, we investigated these impacts using scenarios in three European countries, i. e. Czech Republic, Switzerland and Greece. The assessment was based on modelling the human exposure to fine particles originating from sources of particles within outdoor and indoor air, including environmental tobacco smoke. Exposure response relationships were derived to link (adverse) health effects to the exposure. Furthermore, probable values for the parameters influencing the infiltration of fine particles into residential buildings were modelled. Results show that the insulation and increase of the air-tightness of residential buildings leads to an overall increase of the mean population exposure - and consequently adverse health effects - in all considered countries (ranging for health effects from 0.4% in Czech Republic to 11.8% in Greece for 100% insulated buildings) due to an accumulation of particles indoors, especially from environmental tobacco smoke. Considering only the emission reductions in outdoor air (omitting changes in infiltration parameters) leads to a decrease of adverse health effects. This study highlights the importance of ensuring a sufficient air exchange rate when insulating buildings, e. g. by prescribing heat ventilation and air conditioning systems in new buildings and information campaigns on good airing practice in renovated buildings. It also shows that assessing policy measures based on the exposure may provide different recommendations compared to an assessment based on only the outdoor air concentration.
Analysis of field test data on residential heating and cooling
NASA Astrophysics Data System (ADS)
Talbert, S. G.
1980-12-01
The computer program using field site data collected on 48 homes located in six cities in different climatic regions of the United States is discussed. In addition, a User's Guide was prepared for the computer program which is contained in a separate two-volume document entitled User's Guide for REAP: Residential Energy Analysis Program. Feasibility studies were conducted pertaining to potential improvements for REAP, including: the addition of an oil-furnace model; improving the infiltration subroutine; adding active and/or passive solar subroutines; incorporating a thermal energy storage model; and providing dual HVAC systems (e.g., heat pump-gas furnace). The purpose of REAP is to enable building designers and energy analysts to evaluate how such factors as building design, weather conditions, internal heat loads, and HVAC equipment performance, influence the energy requirements of residential buildings.
NASA Astrophysics Data System (ADS)
Dahlan, F. M.; Zainuddin, A.
2018-02-01
Critical success factors (CSFs) are important key areas of activity that must be performed well in any Facilities Management (FM) organisation to achieve its missions, objectives or goals. Before implementing CSFs, an FM organisation must identify the key areas where things must be done properly to enable the business to flourish. Although many performance measurements in FM organisation have been discussed in previous research, not much research has been done on CSFs from the perspective of FM business in non-low cost high-rise residential buildings. The purpose of this study is to develop a methodology in developing the CSFs group and CSFs for FM organisation in non-low cost residential buildings. This research will involve three (3) phases of research strategy to achieve the objective of this research.
Identification of elements at risk for a credible tsunami event for Istanbul
NASA Astrophysics Data System (ADS)
Hancilar, U.
2012-01-01
Physical and social elements at risk are identified for a credible tsunami event for Istanbul. For this purpose, inundation maps resulting from probabilistic tsunami hazard analysis for a 10% probability of exceedance in 50 yr are utilised in combination with the geo-coded inventories of building stock, lifeline systems and demographic data. The built environment on Istanbul's shorelines that is exposed to tsunami inundation comprises residential, commercial, industrial, public (governmental/municipal, schools, hospitals, sports and religious), infrastructure (car parks, garages, fuel stations, electricity transformer buildings) and military buildings, as well as piers and ports, gas tanks and stations and other urban elements (e.g., recreational facilities). Along the Marmara Sea shore, Tuzla shipyards and important port and petrochemical facilities at Ambarlı are expected to be exposed to tsunami hazard. Significant lifeline systems of the city of Istanbul such as natural gas, electricity, telecommunication and sanitary and waste-water transmission, are also under the threat of tsunamis. In terms of social risk, it is estimated that there are about 32 000 inhabitants exposed to tsunami hazard.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2013-11-01
In 2009, Transformations, Inc. partnered with Building America team Building Science Corporation (BSC) to build new net zero energy houses in three developments in Massachusetts. The company has been developing strategies for cost-effective super-insulated homes in the New England market since 2006. After years of using various construction techniques, it has developed a specific set of assemblies and specifications that achieve a 44.9% reduction in energy use compared with a home built to the 2009 International Residential Code, qualifying the houses for the DOE’s Challenge Home. The super-insulated houses provide data for several research topics in a cold climate. BSCmore » studied the moisture risks in double stud walls insulated with open cell spray foam and cellulose. The mini-split air source heat pump (ASHP) research focused on the range of temperatures experienced in bedrooms as well as the homeowners’ perceptions of equipment performance. BSC also examined the developer’s financing options for the photovoltaic (PV) systems, which take advantage of Solar Renewable Energy Certificates, local incentives, and state and federal tax credits.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2013-11-01
In 2009, Transformations, Inc. partnered with U.S. Department of Energy (DOE) Building America team Building Science Corporation (BSC) to build new net zero energy houses in three developments in Massachusetts. The company has been developing strategies for cost-effective super-insulated homes in the New England market since 2006. After years of using various construction techniques, it has developed a specific set of assemblies and specifications that achieve a 44.9% reduction in energy use compared with a home built to the 2009 International Residential Code, qualifying the houses for the DOE's Challenge Home. The super-insulated houses provide data for several research topicsmore » in a cold climate. BSC studied the moisture risks in double stud walls insulated with open cell spray foam and cellulose. The mini-split air source heat pump (ASHP) research focused on the range of temperatures experienced in bedrooms as well as the homeowners' perceptions of equipment performance. BSC also examined the developer's financing options for the photovoltaic (PV) systems, which take advantage of Solar Renewable Energy Certificates, local incentives, and state and federal tax credits.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Xin; Baker, Kyri A.; Christensen, Dane T.
This paper presents a user-preference-driven home energy management system (HEMS) for demand response (DR) with residential building loads and battery storage. The HEMS is based on a multi-objective model predictive control algorithm, where the objectives include energy cost, thermal comfort, and carbon emission. A multi-criterion decision making method originating from social science is used to quickly determine user preferences based on a brief survey and derive the weights of different objectives used in the optimization process. Besides the residential appliances used in the traditional DR programs, a home battery system is integrated into the HEMS to improve the flexibility andmore » reliability of the DR resources. Simulation studies have been performed on field data from a residential building stock data set. Appliance models and usage patterns were learned from the data to predict the DR resource availability. Results indicate the HEMS was able to provide a significant amount of load reduction with less than 20% prediction error in both heating and cooling cases.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Xin; Baker, Kyri A; Isley, Steven C
This paper presents a user-preference-driven home energy management system (HEMS) for demand response (DR) with residential building loads and battery storage. The HEMS is based on a multi-objective model predictive control algorithm, where the objectives include energy cost, thermal comfort, and carbon emission. A multi-criterion decision making method originating from social science is used to quickly determine user preferences based on a brief survey and derive the weights of different objectives used in the optimization process. Besides the residential appliances used in the traditional DR programs, a home battery system is integrated into the HEMS to improve the flexibility andmore » reliability of the DR resources. Simulation studies have been performed on field data from a residential building stock data set. Appliance models and usage patterns were learned from the data to predict the DR resource availability. Results indicate the HEMS was able to provide a significant amount of load reduction with less than 20% prediction error in both heating and cooling cases.« less
ERIC Educational Resources Information Center
Taylor, Lisa
2014-01-01
In this article, I contextualize and outline my use of testimonial literature, including orature, by residential school survivors in a preservice course focused on building practices of witness-as-study (Simon & Eppert, 2005). My theorization of the course curriculum and pedagogy draws on key texts by Roger Simon as a means of proposing…
ERIC Educational Resources Information Center
Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.
Presented are guidelines for instructors of two courses in the design, installation, and operation of solar heating and cooling systems. These courses are: (1) Design of Systems, and (2) Sizing, Installation, and Operation of Systems. Limited in scope to active solar systems for residential buildings, these courses place primary emphasis upon…
Aramaki, T; Sugimoto, R; Hanaki, K; Matsuo, T
2001-01-01
The appropriate type of reclaimed wastewater reuse system in each area of Tokyo was evaluated from the aspect of economic efficiency, using a GIS-based water balances model. The following four reclaimed wastewater reuse systems and conventional waterworks and sewerage system were evaluated; "Rain water storage and use system", "Onsite wastewater treatment and reuse system", "Sewage treatment and reuse at an intermediate point on the sewer pipe" and "Treated water supply system in sewage treatment plant". In the case that we install them to office and residential buildings, the supplied volume by reclaimed wastewater reuse systems is 693 thousands m3/d, this corresponds to 15% of total water demand in the area. Furthermore, the effects of the following scenarios brought about by technological innovation in water treatment were investigated; the case that flush water in toilet and wastewater from kitchen are also available as source in a "onsite wastewater treatment and reuse system" and the case that reclaimed water is used for laundering in residential buildings. When reclaimed water is used for laundering in residential buildings, the supplied volume by these systems increases to 814 thousand m3/d in the case that these systems are installed to office and residential buildings.
Energy performance standards for new buildings: Economic analysis
NASA Astrophysics Data System (ADS)
1980-01-01
The major economic impacts of the implementations of the standards on affected groups were assessed and the effectiveness of the standards as an investment in energy conservation was evaluated. The methodology used to evaluate the standards for the various building types and perspectives is described. The net economic effect of changes in building cost and energy use are discussed for three categories of buildings: single family residential, commercial and multifamily residential, and mobile homes. Forecasts of energy savings and national costs and benefits both with and without implementation of the standards are presented. The effects of changes in energy consumption and construction of new buildings on the national economy, including such factors as national income, investment, employment, and balance of trade are assessed.
Disposal of Kitchen Waste from High Rise Apartment
NASA Astrophysics Data System (ADS)
Ori, Kirki; Bharti, Ajay; Kumar, Sunil
2017-09-01
The high rise building has numbers of floor and rooms having variety of users or tenants for residential purposes. The huge quantities of heterogenous mixtures of domestic food waste are generated from every floor of the high rise residential buildings. Disposal of wet and biodegradable domestic kitchen waste from high rise buildings are more expensive in regards of collection and vertical transportation. This work is intended to address the technique to dispose of the wet organic food waste from the high rise buildings or multistory building at generation point with the advantage of gravity and vermicomposting technique. This innovative effort for collection and disposal of wet organic solid waste from high rise apartment is more economical and hygienic in comparison with present system of disposal.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-02
.... Surrounding land uses include residential, commercial, recreational, and industrial uses. To the north and... School. To the south are industrial uses. Across Texas Street to the east are multi-family residential, single-family residential, and industrial uses. The obsolete buildings that make up the site are in need...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rutberg, Michael; Hastbacka, Mildred; Bouza, Antonio
2013-07-31
The article discusses thermal energy storage approaches for residential buildings. This article addresses both brick bank storage and phase change material technologies. The energy savings and market potential of these thermal energy storage methods are reviewed as well.
44 CFR 61.5 - Special terms and conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to have an ownership interest in the covered property at the location described in the policy...,000 5,000 1 Also applies to residential unit contents in other residential building or in multi-unit...
Villoria Sáez, Paola; del Río Merino, Mercedes; Porras-Amores, César
2012-02-01
The management planning of construction and demolition (C&D) waste uses a single indicator which does not provide enough detailed information. Therefore the determination and implementation of other innovative and precise indicators should be determined. The aim of this research work is to improve existing C&D waste quantification tools in the construction of new residential buildings in Spain. For this purpose, several housing projects were studied to determine an estimation of C&D waste generated during their construction process. This paper determines the values of three indicators to estimate the generation of C&D waste in new residential buildings in Spain, itemizing types of waste and construction stages. The inclusion of two more accurate indicators, in addition to the global one commonly in use, provides a significant improvement in C&D waste quantification tools and management planning.
Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. The location of the insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. For thick layers of exterior insulation (more than 1.5 in.), the use of wood furring strips attached through the insulation back to the structure has been usedmore » by many contractors and designers as a means to provide a convenient cladding attachment location. Although the approach has proven effective, there is significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, Danny S.; Cummings, Jamie E.; Vieira, Robin K.
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
ERIC Educational Resources Information Center
Serbati, Sara; Gioga, Gianmaria
2017-01-01
Qualitative methods (i.e. semi-structured interviews) were used in this micro-research to explore the different ways in which young people and social and residential workers perceive the outcomes of the residential care experience. By comparing the participants' points of view, it was possible to investigate different ways of thinking about…
NASA Astrophysics Data System (ADS)
Ani, Adi Irfan Che; Sairi, Ahmad; Tawil, Norngainy Mohd; Wahab, Siti Rashidah Hanum Abd; Razak, Muhd Zulhanif Abd
2016-08-01
High demand for housing and limited land in town area has increasing the provision of high-rise residential scheme. This type of housing has different owners but share the same land lot and common facilities. Thus, maintenance works of the buildings and common facilities must be well organized. The purpose of this paper is to identify and classify basic facilities for high-rise residential building hoping to improve the management of the scheme. The method adopted is a survey on 100 high-rise residential schemes that ranged from affordable housing to high cost housing by using a snowball sampling. The scope of this research is within Kajang area, which is rapidly developed with high-rise housing. The objective of the survey is to list out all facilities in every sample of the schemes. The result confirmed that pre-determined 11 classifications hold true and can provide the realistic classification for high-rise residential scheme. This paper proposed for redefinition of facilities provided to create a better management system and give a clear definition on the type of high-rise residential based on its facilities.
CONTRIBUTIONS OF BUILDING MATERIALS TO INDOOR RADON LEVELS IN FLORIDA BUILDINGS
The report documents work to characterize potential radon sources in concretes and recommend related changes to Florida's building materials radium standard. (NOTE: The Florida Standard for Radon-resistant Residential Building Construction originally contained a provision to limi...
Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards The California Building Standards Commission (Commission) published mandatory building standards for EVSE installation in parking spaces at multi-family dwellings and non-residential developments in the California Green Building
Improving Thermal Performance of a Residential Building, Related to Its Orientations - A Case Study
NASA Astrophysics Data System (ADS)
Akshaya, S.; Harish, S.; Arthy, R.; Muthu, D.; Venkatasubramanian, C.
2017-07-01
Urban planners and stakeholders require knowledge about the effectiveness of city-scale climate adaptation measures in order to develop climate resilient cities and to push forward the political process for the implementation of climate adaptation strategies. This study examines the impact of modifications in orientation of buildings with respect to heat load. Heat load calculation is a mathematical process to determine the best capacity, application and style of HVAC system. The purpose is to ensure energy efficiency while also maximizing comfort inside the building. This study of load calculation is essential for a building because it helps to pick the best orientation and focuses to find an orientation that will reduce energy due to direct solar radiation. One of the factors affecting this assessment is the latitude of the location. The heat gain is effective through walls and fenestration. Improper management through ineffective orientation of the building’s natural heat gain leads to excessive consumption of energy in the form of CL. The total heat gain for the above factors is calculated with the equations and assumptions as per ASHRAE code. After the calculation of heat load for different orientations, the best suited orientation of the building is found. By altering the building to suitable orientation, the dependence on electrical equipment can be minimized and thereby helps in energy conservation.
Video: NREL and Buildings Research - Continuum Magazine | NREL
solutions to improve the energy efficiency of both residential and commercial buildings, and to accelerate the integration of clean energy technologies with buildings. NREL's commercial buildings research focuses on providing large institutional and private sector commercial building owners with tools
Climate Impacts on Extreme Energy Consumption of Different Types of Buildings
Li, Mingcai; Shi, Jun; Guo, Jun; Cao, Jingfu; Niu, Jide; Xiong, Mingming
2015-01-01
Exploring changes of building energy consumption and its relationships with climate can provide basis for energy-saving and carbon emission reduction. Heating and cooling energy consumption of different types of buildings during 1981-2010 in Tianjin city, was simulated by using TRNSYS software. Daily or hourly extreme energy consumption was determined by percentile methods, and the climate impact on extreme energy consumption was analyzed. The results showed that days of extreme heating consumption showed apparent decrease during the recent 30 years for residential and large venue buildings, whereas days of extreme cooling consumption increased in large venue building. No significant variations were found for the days of extreme energy consumption for commercial building, although a decreasing trend in extreme heating energy consumption. Daily extreme energy consumption for large venue building had no relationship with climate parameters, whereas extreme energy consumption for commercial and residential buildings was related to various climate parameters. Further multiple regression analysis suggested heating energy consumption for commercial building was affected by maximum temperature, dry bulb temperature, solar radiation and minimum temperature, which together can explain 71.5 % of the variation of the daily extreme heating energy consumption. The daily extreme cooling energy consumption for commercial building was only related to the wet bulb temperature (R2= 0.382). The daily extreme heating energy consumption for residential building was affected by 4 climate parameters, but the dry bulb temperature had the main impact. The impacts of climate on hourly extreme heating energy consumption has a 1-3 hour delay in all three types of buildings, but no delay was found in the impacts of climate on hourly extreme cooling energy consumption for the selected buildings. PMID:25923205
Climate impacts on extreme energy consumption of different types of buildings.
Li, Mingcai; Shi, Jun; Guo, Jun; Cao, Jingfu; Niu, Jide; Xiong, Mingming
2015-01-01
Exploring changes of building energy consumption and its relationships with climate can provide basis for energy-saving and carbon emission reduction. Heating and cooling energy consumption of different types of buildings during 1981-2010 in Tianjin city, was simulated by using TRNSYS software. Daily or hourly extreme energy consumption was determined by percentile methods, and the climate impact on extreme energy consumption was analyzed. The results showed that days of extreme heating consumption showed apparent decrease during the recent 30 years for residential and large venue buildings, whereas days of extreme cooling consumption increased in large venue building. No significant variations were found for the days of extreme energy consumption for commercial building, although a decreasing trend in extreme heating energy consumption. Daily extreme energy consumption for large venue building had no relationship with climate parameters, whereas extreme energy consumption for commercial and residential buildings was related to various climate parameters. Further multiple regression analysis suggested heating energy consumption for commercial building was affected by maximum temperature, dry bulb temperature, solar radiation and minimum temperature, which together can explain 71.5 % of the variation of the daily extreme heating energy consumption. The daily extreme cooling energy consumption for commercial building was only related to the wet bulb temperature (R2= 0.382). The daily extreme heating energy consumption for residential building was affected by 4 climate parameters, but the dry bulb temperature had the main impact. The impacts of climate on hourly extreme heating energy consumption has a 1-3 hour delay in all three types of buildings, but no delay was found in the impacts of climate on hourly extreme cooling energy consumption for the selected buildings.
ICC 700-2012: 2012 National Green Building Standard (ICC 700)
Description of the ICC 700-2012: 2012 National Green Building Standard, a rating and certification system that aims to encourage increased environmental and health performance in residences and residential portions of buildings.
NASA Astrophysics Data System (ADS)
Źróbek-Różańska, Alina; Zysk, Elżbieta; Źróbek, Ryszard
2017-10-01
Poland has experienced many political, legal, social and economic transformations. For the last twelve decades, this country was under foreign partition, in the war, under the influence of socialist system with centrally planned economy and finally regained autonomy and rapidly introduced market economy. Each epoch had its own characteristic, that can be recognized also in the residential buildings development. Therefore, the authors focused on the social, economic, legal and planning conditionings that shaped the development of the residential buildings with the most characteristic periods: pre-II world war, 50-ties, 60-ties, 70-ties, 80-ties, 90-ties and XXI century. Some of them are visible in the still existing residential buildings, especially in the suburban villages. The most recent process that can be observed in the study area is urban sprawl. Since the beginning of the XXI century, urban population in Poland has been gradually declining, while suburban villages transform into ‘urban-like’ districts. The aim of the study was to arrange and present in the decade-by-decade manner, the social, economic, legal and planning conditionings that were valid in particular periods. It was realized by correlating information on the contemporary social trends, economic conditions, legal framework and planning regulations. Presentation was enriched by the examples of the buildings developed in the accordance with the contemporary restrictions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2012-02-01
This report summarizes key findings and outcomes from the U.S. Department of Energy's Building America Residential Energy Efficiency Research Planning meeting, held on October 28-29, 2011, in Washington, D.C.
Analysis of EnergyPlus for use in residential building energy optimization
NASA Astrophysics Data System (ADS)
Spencer, Justin S.
This work explored the utility of EnergyPlus as a simulation engine for doing residential building energy optimization, with the objective of finding the modeling areas that require further development in EnergyPlus for residential optimization applications. This work was conducted primarily during 2006-2007, with publication occurring later in 2010. The assessments and recommendations apply to the simulation tool versions available in 2007. During this work, an EnergyPlus v2.0 (2007) input file generator was developed for use in BEopt 0.8.0.4 (2007). BEopt 0.8.0.4 is a residential Building Energy optimization program developed at the National Renewable Energy Laboratory in Golden, Colorado. Residential modeling capabilities of EnergyPlus v2.0 were scrutinized and tested. Modeling deficiencies were identified in a number of areas. These deficiencies were compared to deficiencies in the DOE2.2 V44E4(2007)/TRNSYS simulation engines. The highest priority gaps in EnergyPlus v2.0's residential modeling capability are in infiltration, duct leakage, and foundation modeling. Optimization results from DOE2.2 V44E4 and EnergyPlus v2.0 were analyzed to search for modeling differences that have a significant impact on optimization results. Optimal buildings at different energy savings levels were compared to look for biases. It was discovered that the EnergyPlus v2.0 optimizations consistently chose higher wall insulation levels than the DOE2.2 V44E4 optimizations. The points composing the optimal paths chosen by DOE2.2 V44E4 and EnergyPlus v2.0 were compared to look for points chosen by one optimization that were significantly different from the other optimal path. These outliers were compared to consensus optimal points to determine the simulation differences that cause disparities in the optimization results. The differences were primarily caused by modeling of window radiation exchange and HVAC autosizing.
Housing price gradient and immigrant population: Data from the Italian real estate market.
Antoniucci, Valentina; Marella, Giuliano
2018-02-01
The database presented here was collected by Antoniucci and Marella to analyze the correlation between the housing price gradient and the immigrant population in Italy during 2016. It may also be useful in other statistical analyses, be they on the real estate market or in another branches of social science. The data sample relates to 112 Italian provincial capitals. It provides accurate information on urban structure, and specifically on urban density. The two most significant variables are original indicators constructed from official data sources: the housing price gradient, or the ratio between average prices in the center and suburbs by city; and building density, which is the average number of housing units per residential building. The housing price gradient is calculated for the two residential sub-markets, new-build and existing units, providing an original and detailed sample of the Italian residential market. Rather than average prices, the housing price gradient helps to identify potential divergences in residential market trends. As well as house prices, two other data clusters are considered: socio-economic variables, which provide a framework of each city, in terms of demographic and economic information; and various data on urban structure, which are rarely included in the same database.
Joe Elling; David B. McKeever
2015-01-01
New residential construction is a critical driver of the demand for lumber, structural panels and engineered wood products in Canada. For the period 2010 through 2013, residential construction accounted for roughly 23 percent of the lumber consumed in Canada and 47 percent of structural panel usage. Insufficient data concerning imports and exports prevent estimates of...
VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Xin
2016-07-01
Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use inmore » the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.« less
Using Sustainable Development as a Competitive Strategy
NASA Astrophysics Data System (ADS)
Spearman, Pat
Sustainable development reduces construction waste by 43%, generating 50% cost savings. Residential construction executives lacking adequate knowledge regarding the benefits of sustainable development practices are at a competitive disadvantage. Drawing from the diffusion of innovation theory, the purpose of this qualitative case study was to explore knowledge acquisition within the bounds of sustainable residential construction. The purposive sample size of 11 executive decision makers fulfilled the sample size requirements and enabled the extraction of meaningful data. Participants were members of the National Home Builders Association and had experience of a minimum of 5 years in residential construction. The research question addressed how to improve knowledge acquisition relating to the cost benefits of building green homes and increase the adoption rate of sustainable development among residential builders. Data were collected via semistructured telephone interviews, field observation, and document analysis. Transcribed data were validated via respondent validation, coded into 5 initial categories aligned to the focus of the research, then reduced to 3 interlocking themes of environment, competitive advantage, and marketing. Recommendations include developing comprehensive public policies, horizontal and vertical communications networks, and green banks to capitalize sustainable development programs to improve the diffusion of green innovation as a competitive advantage strategy. Business leaders could benefit from this data by integrating sustainable development practices into their business processes. Sustainable development reduces operational costs, increases competitive advantage for builders, and reduces greenhouse gas emissions. Implications for social change increase energy independence through conservation and developing a legislative policy template for comprehensive energy strategies. A comprehensive energy strategy promotes economic development, technological gains in all business sectors within the energy industry, and reduces energy costs for consumers.
BEopt - Building Energy Optimization BEopt NREL - National Renewable Energy Laboratory Primary Energy Optimization) software provides capabilities to evaluate residential building designs and identify sequential search optimization technique used by BEopt: Finds minimum-cost building designs at different
SUNREL Publications | Buildings | NREL
Energy Simulation with a Three-Dimensional Ground-Coupled Heat Transfer Model Infiltration and Natural Ventilation Model for Whole-Building Energy Simulation of Residential Buildings Improvements to the SERIRES /SUNREL Building Energy Simulation Program, Deru, M. 1996. Masters Thesis, Colorado State University, Fort
Comfort air temperature influence on heating and cooling loads of a residential building
NASA Astrophysics Data System (ADS)
Stanciu, C.; Șoriga, I.; Gheorghian, A. T.; Stanciu, D.
2016-08-01
The paper presents the thermal behavior and energy loads of a two-level residential building designed for a family of four, two adults and two students, for different inside comfort levels reflected by the interior air temperature. Results are intended to emphasize the different thermal behavior of building elements and their contribution to the building's external load. The most important contributors to the building thermal loss are determined. Daily heating and cooling loads are computed for 12 months simulation in Bucharest (44.25°N latitude) in clear sky conditions. The most important aspects regarding sizing of thermal energy systems are emphasized, such as the reference months for maximum cooling and heating loads and these loads’ values. Annual maximum loads are encountered in February and August, respectively, so these months should be taken as reference for sizing thermal building systems, in Bucharest, under clear sky conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Building cost effective, high performance homes that provide superior comfort, health, and durability is the goal of the Department of Energy's (DOE's) Zero Energy Ready Homes (ZERH) program. Through Building America research and other innovative programs throughout the country, many of the technical challenges to building to the ZERH standard have been addressed. This case study describes the development of a 62-unit multifamily community constructed by nonprofit developer Mutual Housing at the Spring Lake subdivision in Woodland, CA. The Spring Lake project is expected to be the first ZERH-certified multifamily project nationwide. Building America team Alliance for Residential Building Innovationmore » worked with Mutual Housing throughout the project. The case study discusses challenges encountered, lessons learned, and how obstacles were overcome. An objective of this project was to gain a highly visible foothold for residential buildings built to the DOE ZERH specification that can be used to encourage participation by other California builders.« less
Engvall, Karin; Hult, M; Corner, R; Lampa, E; Norbäck, D; Emenius, G
2010-01-01
The aim was to develop a new model to identify residential buildings with higher frequencies of "SBS" than expected, "risk buildings". In 2005, 481 multi-family buildings with 10,506 dwellings in Stockholm were studied by a new stratified random sampling. A standardised self-administered questionnaire was used to assess "SBS", atopy and personal factors. The response rate was 73%. Statistical analysis was performed by multiple logistic regressions. Dwellers owning their building reported less "SBS" than those renting. There was a strong relationship between socio-economic factors and ownership. The regression model, ended up with high explanatory values for age, gender, atopy and ownership. Applying our model, 9% of all residential buildings in Stockholm were classified as "risk buildings" with the highest proportion in houses built 1961-1975 (26%) and lowest in houses built 1985-1990 (4%). To identify "risk buildings", it is necessary to adjust for ownership and population characteristics.
Chiappini, L; Delery, L; Leoz, E; Brouard, B; Fagault, Y
2009-06-01
Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies. In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-31
Describes a study undertaken to assess the indoor air quality in the Clos St-Andre, a 78-unit residential complex in downtown Montreal, through the implementation of a monitoring protocol in three of the building`s suites; and to examine the relationships between mechanical ventilation, material emissions, occupant lifestyle, and indoor air pollutant concentrations. The monitoring protocol consisted of tracer gas, air exchange testing, material emission testing, airtightness testing, and the monitoring of air temperature, relative humidity, carbon dioxide, carbon monoxide, formaldehyde, and total volatile organic carbon in the suites. Trends in pollutant concentrations over time in the post-construction period are noted.
A second level of the Saint Petersburg skyline
NASA Astrophysics Data System (ADS)
Krasnopolsky, Andrey; Bolotin, Sergey
2018-03-01
The article considers the history of the residential development in Saint Petersburg and states corresponding landmark dates. In recent years, changes in the altitude range of the residential development are noted, the influence of this factor on the formation of the city's silhouette is assessed. Reasons for such changes are identified. Attractiveness of high-rise residential complexes for living is assessed. Conclusions are made of tendencies in further housing construction development in terms of its altitude range. It is noted that it is possible to locate multi-storied buildings in the periphery of the city, taking into account specific visual characteristics of the construction site and silhouette of erected buildings; as for central districts, strict regulations regarding the altitude range are needed.
Home Energy Scoring Tools (website) and Application Programming Interfaces, APIs (aka HEScore)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, Evan; Bourassa, Norm; Rainer, Leo
A web-based residential energy rating tool with APIs that runs the LBNL website: Provides customized estimates of residential energy use and energy bills based on building description information provided by the user. Energy use is estimated using engineering models developed at LBNL. Space heating and cooling use is based on the DOE-2. 1E building simulation model. Other end-users (water heating, appliances, lighting, and misc. equipment) are based on engineering models developed by LBNL.
Home Energy Scoring Tools (website) and Application Programming Interfaces, APIs (aka HEScore)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, Evan; Bourassa, Norm; Rainer, Leo
2016-04-22
A web-based residential energy rating tool with APIs that runs the LBNL website: Provides customized estimates of residential energy use and energy bills based on building description information provided by the user. Energy use is estimated using engineering models developed at LBNL. Space heating and cooling use is based on the DOE-2. 1E building simulation model. Other end-users (water heating, appliances, lighting, and misc. equipment) are based on engineering models developed by LBNL.
Dynamic Geospatial Modeling of the Building Stock to Project Urban Energy Demand.
Breunig, Hanna Marie; Huntington, Tyler; Jin, Ling; Robinson, Alastair; Scown, Corinne Donahue
2018-06-26
In the United States, buildings account for more than 40 percent of total energy consumption, and the evolution of the urban form will impact the effectiveness of strategies to reduce energy use and mitigate emissions. This paper presents a broadly applicable approach for modeling future commercial, residential, and industrial floorspace, thermal consumption (heating and cooling), and associated GHG emissions at the tax assessor land parcel level. The approach accounts for changing building standards and retrofitting, climate change, and trends in housing and industry. We demonstrate the automated workflow for California, and project building stock, thermal energy consumption, and associated GHG emissions out to 2050. Our results suggest that if buildings in California have long lifespans, and minimal energy efficiency improvements compared to building codes reflective of 2008, then the state will face a 20% or higher increase in thermal energy consumption by 2050. Baseline annual GHG emissions associated with thermal energy consumption in the modeled building stock in 2016 is 34% below 1990 levels (110 Mt CO2eq/y).While the 2020 targets for the reduction of GHG emissions set by the California Senate Bill 350 have already been met, none of our scenarios achieve >80% reduction from 1990 levels by 2050, despite assuming an 86% reduction in electricity carbon intensity in our "Low Carbon" scenario. The results highlight the challenge California faces in meeting its new energy efficiency targets unless the State's building stock undergoes timely and strategic turnover, paired with deep retrofitting of existing buildings and natural gas equipment.
SUNREL Applications | Buildings | NREL
used by the building design team for energy analysis. Zion National Park Visitor's Center Grand Canyon National Park Bookstore NREL Thermal Test Facility NREL Wind Site Entrance Building DPD Office Building Performance Analysis of a High-Mass Residential Building Van Geet residence The Van Geet Off-Grid Home: An
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Receptacles. 434.515 Section 434.515 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL... Hotel/Motel 0.25 Restaurant 0.1 Health 1.0 Multi-family High Rise Residential Included in Lights and...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Occupancy. 434.513 Section 434.513 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL... 100 Health/Institutional 200 Multi-family High-rise Residential 2 per unit . 1 1 Heat generation: Btu...
Performance of Buildings in the 2009 Western Sumatra Earthquake
NASA Astrophysics Data System (ADS)
Deierlein, G.; Hart, T.; Alexander, N.; Hausler, E.; Henderson, S.; Wood, K.; Cedillos, V.; Wijanto, S.; Cabrera, C.; Rudianto, S.
2009-12-01
The M7.6 earthquake of 30 September 2009 in Western Sumatra, Indonesia caused significant damage and collapse to hundreds of buildings and the deaths of 1,117 people. In Padang City, with a population of about 900,000 people, building collapse was the primary cause of deaths and serious injuries (313 deaths and 431 serious injuries). The predominant building construction types in Padang are concrete moment frames with brick infill and masonry bearing wall systems. Concrete frames are common in multistory commercial retail buildings, offices, schools, and hotels; and masonry bearing wall systems are primarily used in low-rise (usually single story) residential and school buildings. In general, buildings that collapsed did not conform to modern seismic engineering practices that are required by the current Indonesian building code and would be expected in regions of moderate to high seismicity. While collapse of multi-story concrete buildings was more prevalent in older buildings (more than 10 years old), there were several newer buildings that collapsed. Primary deficiencies identified in collapsed or severely damaged buildings included: (a) soft or weak stories that failed in either by sidesway mechanisms or shear failures followed by loss of axial capacity of columns, (b) lack of ductile reinforcing bar detailing in concrete beams, columns, and beam-column joints, (c) poor quality concrete and mortar materials and workmanship, (d) vulnerable building configurations and designs with incomplete or deficient load paths, and (e) out-of-plane wall failures in unreinforced (or marginally reinforced) masonry. While these deficiencies may be expected in older buildings, damage and collapse to some modern (or recently rennovated buildings) indicates a lack of enforcement of building code provisions for design and construction quality assurance. Many new buildings whose structural systems were undamaged were closed due to extensive earthquake damage to brick infill walls, glass facades, ceiling systems and other architectural finishes. These demonstrated the importance of considering deformation compatibility and seismic considerations in the design and detail of architectural elements and non-structural components. Another important lesson learned from this earthquake is the critical role that buildings serve for vertical evacuation (refuge) from tsunami inundation in Padang and similar coastal cities in regions of high tsunami hazards. Severe traffic congestion immediately after the September 30 earthquake demonstrated that horizontal evacuation alone is insufficient to safely evacuate Padang City residents to high ground. Therefore, efforts must be stepped up to pre-screen, assess, and engineer buildings tha can be utilized for vertical evacuation.
McDermott, Michael J; Mazor, Kimberly A; Shost, Stephen J; Narang, Rajinder S; Aldous, Kenneth M; Storm, Jan E
2005-10-01
Fugitive tetrachloroethylene (PCE, perc) emissions from dry cleaners operating in apartment buildings can contaminate residential indoor air. In 1997, New York State and New York City adopted regulations to reduce and contain perc emissions from dry cleaners located in residential and other buildings. As part of a New York State Department of Health (NYSDOH) study, indoor air perc levels were determined in 65 apartments located in 24 buildings in New York City where dry cleaners used perc on site. Sampling occurred during 2001-2003, and sampled buildings were dispersed across minority and nonminority as well as low-income and higher income neighborhoods. For the entire study area, the mean apartment perc level was 34 microg/m3, 10-fold lower than mean apartment levels of 340-360 microg/m3 documented before 1997. The maximum detected perc level was 5,000 microg/m3, 5-fold lower than the maximum of 25,000 microg/m3 documented before 1997. Despite these accomplishments, perc levels in 17 sampled apartments still exceeded the NYSDOH residential air guideline of 100 microg/m3, and perc levels in 4 sampled apartments exceeded 1,000 microg/m3. Moreover, mean indoor air perc levels in minority neighborhoods (75 microg/m3) were four times higher than in nonminority households (19 microg/m3) and were > 10 times higher in low-income neighborhoods (256 microg/m3) than in higher income neighborhoods (23 microg/m3). Logistic regression suitable for clustered data (apartments within buildings) indicated that perc levels on floors 1-4 were significantly more likely to exceed 100 microg/m3 in buildings located in minority neighborhoods (odds ratio = 6.7; 95% confidence interval, 1.5-30.5) than in nonminority neighborhoods. Factors that may be contributing to the elevated perc levels detected, especially in minority and low-income neighborhoods, are being explored.
GREEN RETROFITTING RESIDENTIAL BUILDINGS
When compared with the rest of the world, the United States consumes a disproportionately large amount of energy and is a major source of greenhouse gases from fossil fuel combustion. As much as two thirds of U.S. electricity production is consumed by residential and commerci...
DOT National Transportation Integrated Search
2015-02-01
This research builds on the related Phase 1 project. In this second phase, we continue to : study neighborhood and housing preferences that shape the residential location decision process. An : online experimental survey tool is developed to investig...
Residential Construction Trends in America's Metropolitan Regions: 2010 and 2009 Editions
These two reports examine residential building permits in the 50 largest U.S. metropolitan regions at the county or jurisdictional level to determine whether there has been a shift toward redevelopment and which regions have seen the most change.
1. EXTERIOR OVERVIEW SHOWING BISHOP CREEK PLANT 4 RESIDENTIAL COMPLEX. ...
1. EXTERIOR OVERVIEW SHOWING BISHOP CREEK PLANT 4 RESIDENTIAL COMPLEX. BUILDING 122 IS VISIBLE AT PHOTO CENTER. PLANT 5 INTAKE DAM AT PHOTO LEFT. VIEW TO WEST. - Bishop Creek Hydroelectric System, Plant 4, Worker Cottage, Bishop Creek, Bishop, Inyo County, CA
Mercader-Moyano, Pilar; Ramírez-de-Arellano-Agudo, Antonio
2013-05-01
The unfortunate economic situation involving Spain and the European Union is, among other factors, the result of intensive construction activity over recent years. The excessive consumption of natural resources, together with the impact caused by the uncontrolled dumping of untreated C&D waste in illegal landfills have caused environmental pollution and a deterioration of the landscape. The objective of this research was to generate a selective classification and quantification model of C&D waste based on the material resources consumed in the construction of residential buildings, either new or renovated, namely the Conventional Constructive Model (CCM). A practical example carried out on ten residential buildings in Seville, Spain, enabled the identification and quantification of the C&D waste generated in their construction and the origin of the waste, in terms of the building material from which it originated and its impact for every m(2) constructed. This model enables other researchers to establish comparisons between the various improvements proposed for the minimization of the environmental impact produced by building a CCM, new corrective measures to be proposed in future policies that regulate the production and management of C&D waste generated in construction from the design stage to the completion of the construction process, and the establishment of sustainable management for C&D waste and for the selection of materials for the construction on projected or renovated buildings.
An international survey of building energy codes and their implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, andmore » geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
76 FR 31471 - Ethylene Glycol; Exemption From the Requirement of a Tolerance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-01
... production (NAICS code 112). Food manufacturing (NAICS code 311). Pesticide manufacturing (NAICS code 32532..., submitted a petition to EPA under the Federal Food, Drug, and Cosmetic Act (FFDCA), requesting an... residual, and crack and crevice sprays in and around food and nonfood areas of residential and...
Typological diversity of tall buildings and complexes in relation to their functional structure
NASA Astrophysics Data System (ADS)
Generalov, Viktor P.; Generalova, Elena M.; Kalinkina, Nadezhda A.; Zhdanova, Irina V.
2018-03-01
The paper focuses on peculiarities of tall buildings and complexes, their typology and its formation in relation to their functional structure. The research is based on the analysis of tall buildings and complexes and identifies the following main functional elements of their formation: residential, administrative (office), hotel elements. The paper also considers the following services as «disseminated» in the space-planning structure: shops, medicine, entertainment, kids and sports facilities, etc., their location in the structure of the total bulk of the building and their impact on typological diversity. Research results include suggestions to add such concepts as «single-function tall buildings» and «mixed-use tall buildings and complexes» into the classification of tall buildings. In addition, if a single-function building or complex performs serving functions, it is proposed to add such concepts as «a residential tall building (complex) with provision of services», «an administrative (public) tall building (complex) with provision of services» into the classification of tall buildings. For mixed-use buildings and complexes the following terms are suggested: «a mixed-use tall building with provision of services», «a mixed-use tall complex with provision of services».
, developing an analysis framework and data visualization for national residential building stock models, and include developing multifamily modeling capabilities for the BEopt building energy optimization software
NASA Astrophysics Data System (ADS)
Masztalski, Robert; Michalski, Marcin
2016-03-01
The article presents the urban structure of the North-East of Wroclaw, where in the vicinity of the historic buildings and residential buildings from the 70s of the last century, and between, in the last 20 years there were built new buildings, as binding material of the urban structure. The new multifamily housing development of years 2000-2014 of Psie Pole as a housing development in Wroclaw, closes the gap between the historic district residential buildings in the old Psie Pole and the buildings of large slabs of the 70s of the twentieth century. The contemporary residential development uses the existing social infrastructure centre of the old Psie Pole district, and also the social infrastructure of the housing development of 70s of the twentieth century. The authors analyze, in the first part, the spatial development of these areas on the basis of historical materials. In the following, based on an analysis of urban structure created in the last 15 years of development, analyze existing conditions, context and value (in terms of urban planning - the wealth of social infrastructure), the contemporary housing development of Psie Pole.
Economic aspects of possible residential heating conservation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hopkowicz, M.; Szul, A.
1995-12-31
The paper presents methods of evaluation of energy and economy related effects of different actions aimed at conservation in residential buildings. It identifies also the method of selecting the most effective way of distribution funds assigned to weatherization as well as necessary improvements to be implemented within the heating node and the internal heating system of the building. The analysis of data gathered for four 11-stories high residential buildings of {open_quotes}Zeran{close_quotes} type being subject of the Conservation Demonstrative Project, included a differentiated scope of weatherization efforts and various actions aimed at system upgrading. Basing upon the discussion of the splitmore » of heat losses in a building as well as the established energy savings for numerous options of upgrading works, the main problem has been defined. It consists in optimal distribution of financial means for the discussed measures if the total amount of funds assigned for modifications is defined. The method based upon the principle of relative increments has been suggested. The economical and energy specifications of the building and its components, required for this method have also been elaborated. The application of this method allowed to define the suggested optimal scope of actions within the entire fund assigned for the comprehensive weatherization.« less
Work with Us | Buildings | NREL
opportunities to take advantage of our residential and commercial buildings expertise. Here's how you can work commercial and public sectors to improve building energy performance is central to its mission. Learn about available for collaborative research opportunities. Commercial Solutions NREL's Commercial Buildings team
Using safety inspection data to estimate shaking intensity for the 1994 Northridge earthquake
Thywissen, K.; Boatwright, J.
1998-01-01
We map the shaking intensity suffered in Los Angeles County during the 17 January 1994, Northridge earthquake using municipal safety inspection data. The intensity is estimated from the number of buildings given red, yellow, or green tags, aggregated by census tract. Census tracts contain from 200 to 4000 residential buildings and have an average area of 6 km2 but are as small as 2 and 1 km2 in the most densely populated areas of the San Fernando Valley and downtown Los Angeles, respectively. In comparison, the zip code areas on which standard MMI intensity estimates are based are six times larger, on average, than the census tracts. We group the buildings by age (before and after 1940 and 1976), by number of housing units (one, two to four, and five or more), and by construction type, and we normalize the tags by the total number of similar buildings in each census tract. We analyze the seven most abundant building categories. The fragilities (the fraction of buildings in each category tagged within each intensity level) for these seven building categories are adjusted so that the intensity estimates agree. We calibrate the shaking intensity to correspond with the modified Mercalli intensities (MMI) estimated and compiled by Dewey et al. (1995); the shapes of the resulting isoseismals are similar, although we underestimate the extent of the MMI = 6 and 7 areas. The fragility varies significantly between different building categories (by factors of 10 to 20) and building ages (by factors of 2 to 6). The post-1940 wood-frame multi-family (???5 units) dwellings make up the most fragile building category, and the post-1940 wood-frame single-family dwellings make up the most resistant building category.
Final Technical Report. Training in Building Audit Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brosemer, Kathleen
In 2011, the Tribe proposed and was awarded the Training in Building Audit Technologies grant from the DOE in the amount of $55,748 to contract for training programs for infrared cameras, blower door technology applications and building systems. The coursework consisted of; Infrared Camera Training: Level I - Thermal Imaging for Energy Audits; Blower Door Analysis and Building-As-A-System Training, Building Performance Institute (BPI) Building Analyst; Building Envelope Training, Building Performance Institute (BPI) Envelope Professional; and Audit/JobFLEX Tablet Software. Competitive procurement of the training contractor resulted in lower costs, allowing the Tribe to request and receive DOE approval to additionally purchasemore » energy audit equipment and contract for residential energy audits of 25 low-income Tribal Housing units. Sault Tribe personnel received field training to supplement the classroom instruction on proper use of the energy audit equipment. Field experience was provided through the second DOE energy audits grant, allowing Sault Tribe personnel to join the contractor, Building Science Academy, in conducting 25 residential energy audits of low-income Tribal Housing units.« less
1. EXTERIOR OVERVIEW SHOWING BISHOP CREEK PLANT 4 RESIDENTIAL COMPLEX. ...
1. EXTERIOR OVERVIEW SHOWING BISHOP CREEK PLANT 4 RESIDENTIAL COMPLEX. BUILDING 113 IS VISIBLE AT RIGHT PHOTO CENTER. PLANT 5 INTAKE DAM AT PHOTO LEFT. VIEW TO WEST. - Bishop Creek Hydroelectric System, Plant 4, Worker Cottage, Bishop Creek, Bishop, Inyo County, CA
10 CFR 435.4 - Energy efficiency performance standard.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
10 CFR 435.4 - Energy efficiency performance standard.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
10 CFR 435.4 - Energy efficiency performance standard.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
10 CFR 435.4 - Energy efficiency performance standard.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
10 CFR 435.4 - Energy efficiency performance standard.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. Springer and A. German
2015-09-01
Building cost effective, high performance homes that provide superior comfort, health, and durability is the goal of the Department of Energy's (DOE's) Zero Energy Ready Homes (ZERH) program. This case study describes the development of a 62-unit multifamily community constructed by nonprofit developer Mutual Housing at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project nationwide. Building America team Alliance for Residential Building Innovation worked with Mutual Housing throughout the project. An objective of this project was to gain a highly visible foothold for residential buildings built to themore » DOE ZERH specification that can be used to encourage participation by other California builders.« less
Model of slums rejuvenation in Telaga Tujuh village: the case of Langsa city, Aceh, Indonesia
NASA Astrophysics Data System (ADS)
Irwansyah, Mirza; Caisarina, Irin; Solehati, Dini
2018-05-01
Telaga Tujuh village is the only island inhabited compared to other islands in Langsa City, Aceh. Most of the houses are on stilts with very limited infrastructure such as lack of road facilities, local drainage, drinking water, wastewater, and garbage disposals. In determining the model of the slum settlements arrangement of Telaga Tujuh Village, there are some things to know that the characteristics of slums themselves and the causes of slum settlement. The aim of this study is to determine model of slum settlement arrangement that is suitable to be applied in the location. The method used is qualitative with sampling technique and qualitative analysis. To obtain the primary data used observation method, questionnaires, and interview. Secondary data obtained from agencies related to slum settlement arrangement. Based on characteristic analysis found that 365 residential buildings are irregular with the percentage of 100%, 365 residential buildings do not have safe drinking water supply, 365 residential buildings do not have waste water management. From the analysis shows that the appropriate model to be applied to Telaga Tujuh village is the rejuvenation model with the land consolidation system through the re-arrangement divided by two, 60% for the existing residential development and 40% for commercial development.
NASA Astrophysics Data System (ADS)
Zhang, Linfang; Yu, Zhenyang; Liu, Jiying; Zhang, Linhua
2018-02-01
With the improvement of people’s living standard, people not only pay attention to the indoor environment, but also the outdoor environment. The paper simulated the outdoor wind environment and thermal environment for the building in its design stage, then suggestions are provided for further design stage using a case study in a residential area in Liaocheng, China. SketchUp is used to establish 3D model and PHOENICS is adopted to simulate wind environment and thermal environment. The evaluation criterion mainly utilized Green Building Evaluation Criteria and Urban Residential Area Thermal Environment Design Criteria and ISO7243. Through the analysis of the wind and thermal environment problems, this paper puts forward measures and suggestions to provide reference for the later planning.
Residential Central Air Conditioning and Heat Pump Installation – Workshop Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goetzler, William; Zogg, Robert; Young, Jim
DOE's Building Technologies Office works with researchers and industry partners to develop and deploy technologies that can substantially reduce energy consumption in residential and commercial buildings. This report aims to advance BTO’s energy savings, emissions reduction, and other program goals by identifying research and development (R&D), demonstration and deployment, and other non-regulatory initiatives for improving the design and installation of residential central air conditioners (CAC) and central heat pumps (CHP). Improving the adoption of CAC/CHP design and installation best practices has significant potential to reduce equipment costs, improve indoor air quality and comfort, improve system performance, and most importantly, reducemore » household energy consumption and costs for heating and cooling by addressing a variety of common installation issues.« less
Shahraki, GholamHossein; Bin Ibrahim, Yusof; Noor, Hafidzi Mohd; Rafinejad, Javad; Shahar, Mohd Khadri
2010-08-01
This study assessed the effectiveness of a biorational control approach using 2% hydramethylnon gel bait on German cockroaches, Blattella germanica (L.) in some residential and hospital buildings in South Western Iran. In total, three buildings consisting of 150 apartment units and 101 hospital units were monitored weekly via sticky trap for German cockroach infestations over a period of eight months. These infested units were randomly subjected to intervention and control treatments. Pamphlets and posters were provided and lectures were given to support the educational programmes as a tactic of the biorational system. Survey on cockroach index for intervention units showed 67-94% recovery to achieve clean level of infestation for intervention units of the residential buildings and 83% for the hospital. Mean percentage reductions for treatment groups throughout the 15-week treatment period were 76.8% for the residential buildings and 88.1% for the hospital, showing significant differences compared to the control groups. Linear regression of infestation rates were recorded weekly after treatment and their negative slope for treatment groups substantiated significant reductions for interventions. The results of this study showed that biorational control method, using gel bait, educational programmes and sanitation, is an effective way to manage German cockroach infestation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanford, J.W.; Huang, Y.J.
The energy performance of skylights is similar to that of windows in admitting solar heat gain, while at the same time providing a pathway for convective and conductive heat transfer through the building envelope. Since skylights are typically installed at angles ranging from 0{degrees} to 45{degrees}, and differ from windows in both their construction and operation, their conductive and convective heat gains or losses, as well as solar heat gain, will differ for the same rough opening and thermal characteristics. The objective of this work is to quantify the impact of solar gain through skylights on building heating and coolingmore » loads in 45 climates, and to develop a method for including these data into the SP53 residential loads data base previously developed by LBL in support of DOE`s Automated Residential Energy Standard (ARES) program. The authors used the DOE-2.1C program to simulate the heating and cooling loads of a prototypical residential building while varying the size and solar characteristics of skylights and windows. The results are presented as Skylight Solar Loads, which are the contribution of solar gains through skylights to the overall building heating and cooling loads, and as Skylight Solar Load Ratios, which are the ratios of skylight solar loads to those for windows with the same orientation. The study shows that skylight solar loads are larger than those for windows in both heating and cooling. Skylight solar cooling loads are from three to four times greater than those for windows regardless of the skylight tilt, except for those facing north. These cooling loads are largest for south-facing skylights at a tilt angle of approximately 20{degrees}, and drop off at higher tilts and other orientations.« less
SICK BUILDING SYNDROME: POSSIBLE ASSOCIATIONS WITH EXPOSURE TO MYCOTOXINS FROM INDOOR AIR FUNGI.
Introduction. Chronic human illness associated with residential or occupational buildings, commonly referred to as sick building syndrome (SBS), may be a multifactorial condition, involving in some cases volatile organic compounds, CO or CO2, pesticides, biologic agents, temperat...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1977-08-01
Documents relevant to the development and implementation of the California energy insulation standards for new residential buildings were evaluated and a survey was conducted to determine problems encountered in the implementation, enforcement, and design aspects of the standards. The impact of the standards on enforcement agencies, designers, builders and developers, manufacturers and suppliers, consumers, and the building process in general is summarized. The impact on construction costs and energy savings varies considerably because of the wide variation in prior insulation practices and climatic conditions in California. The report concludes with a series of recommendations covering all levels of government andmore » the building process. (MCW)« less
Wang, Z.; Shi, B.; Kiefer, J.D.
2005-01-01
PSHA is the method used most to assess seismic hazards for input into various aspects of public and financial policy. For example, PSHA was used by the U.S. Geological Survey to develop the National Seismic Hazard Maps (Frankel et al., 1996, 2002). These maps are the basis for many national, state, and local seismic safety regulations and design standards, such as the NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, the International Building Code, and the International Residential Code. Adoption and implementation of these regulations and design standards would have significant impacts on many communities in the New Madrid area, including Memphis, Tennessee and Paducah, Kentucky. Although "mitigating risks to society from earthquakes involves economic and policy issues" (Stein, 2004), seismic hazard assessment is the basis. Seismologists should provide the best information on seismic hazards and communicate them to users and policy makers. There is a lack of effort in communicating the uncertainties in seismic hazard assessment in the central U.S., however. Use of 10%, 5%, and 2% PE in 50 years causes confusion in communicating seismic hazard assessment. It would be easy to discuss and understand the design ground motions if the true meaning of the ground motion derived from PSHA were presented, i.e., the ground motion with the estimated uncertainty or the associated confidence level.
NASA Astrophysics Data System (ADS)
Dong, J. Y.; Cheng, W.; Ma, C. P.; Tan, Y. T.; Xin, L. S.
2017-04-01
The residential public space is an important part in designing the ecological residence, and a proper physics environment of public space is of greater significance to urban residence in China. Actually, the measure to apply computer aided design software into residential design can effectively avoid an inconformity of design intent with actual using condition, and a negative impact on users due to bad architectural physics environment of buildings, etc. The paper largely adopts a design method of analyzing architectural physics environment of residential public space. By analyzing and evaluating various physics environments, a suitability assessment is obtained for residential public space, thereby guiding the space design.
1. EXTERIOR OVERVIEW SHOWING BISHOP CREEK PLANT 4 RESIDENTIAL COMPLEX. ...
1. EXTERIOR OVERVIEW SHOWING BISHOP CREEK PLANT 4 RESIDENTIAL COMPLEX. ROOF OF BUILDING 105 IS VISIBLE IN UPPER PHOTO CENTER. PLANT 5 INTAKE DAM AT PHOTO LEFT. VIEW TO WEST. - Bishop Creek Hydroelectric System, Plant 4, Worker Cottage, Bishop Creek, Bishop, Inyo County, CA
Residential solar-heating system
NASA Technical Reports Server (NTRS)
1978-01-01
Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.
Systems and applications analysis for concentrating photovoltaic-thermal systems
NASA Astrophysics Data System (ADS)
Schwinkendorf, W. E.
Numerical simulations were carried out of the performance, costs, and land use requirements of five commercial and six residential applications of combined photovoltaic-thermal (PVT) power plants. Line focus Fresnel concentrators (LFF) systems were selected after a simulated comparison of different PVT systems. Load profiles were configured from industrial data and ASHRAE and building codes. Assumptions included costs of $1/Wp, 0.15 efficiency, and a cost of $275/sq m, as well as a 25 percent solar tax credit. The calculations showed that a significant low temperature thermal load must be available, but no heat recovery system. Industrial situations were identified which favor solar thermal energy alone rather than a combined system. The thermal energy displacement was determined to be the critical factor in assessing the economics of the PVT systems.
10 CFR 435.306 - Selecting a life cycle effective proposed building design.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...
10 CFR 435.306 - Selecting a life cycle effective proposed building design.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...
10 CFR 435.306 - Selecting a life cycle effective proposed building design.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...
10 CFR 435.306 - Selecting a life cycle effective proposed building design.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Selecting a life cycle effective proposed building design... Residential Buildings § 435.306 Selecting a life cycle effective proposed building design. In selecting... prototype, has the highest Net Savings or lowest total life cycle costs calculated in compliance with...
2015-01-01
The Energy Information Administration (EIA) is investigating the potential benefits of incorporating interval electricity data into its residential energy end use models. This includes interval smart meter and submeter data from utility assets and systems. It is expected that these data will play a significant role in informing residential energy efficiency policies in the future. Therefore, a long-term strategy for improving the RECS end-use models will not be complete without an investigation of the current state of affairs of submeter data, including their potential for use in the context of residential building energy modeling.
Integrated residential photovoltaic array development
NASA Astrophysics Data System (ADS)
Shepard, N. F., Jr.
1981-12-01
An advanced, universally-mountable, integrated residential photovoltaic array concept was defined based upon an in-depth formulation and evaluation of three candidate approaches which were synthesized from existing or proposed residential array concepts. The impact of module circuitry and process sequence is considered and technology gaps and performance drivers associated with residential photovoltaic array concepts are identified. The actual learning experience gained from the comparison of the problem areas of the hexagonal shingle design with the rectangular module design led to what is considered an advanced array concept. Building the laboratory mockup provided actual experience and the opportunity to uncover additional technology gaps.
Integrated residential photovoltaic array development
NASA Technical Reports Server (NTRS)
Shepard, N. F., Jr.
1981-01-01
An advanced, universally-mountable, integrated residential photovoltaic array concept was defined based upon an in-depth formulation and evaluation of three candidate approaches which were synthesized from existing or proposed residential array concepts. The impact of module circuitry and process sequence is considered and technology gaps and performance drivers associated with residential photovoltaic array concepts are identified. The actual learning experience gained from the comparison of the problem areas of the hexagonal shingle design with the rectangular module design led to what is considered an advanced array concept. Building the laboratory mockup provided actual experience and the opportunity to uncover additional technology gaps.
10 CFR 434.402 - Building envelope assemblies and materials.
Code of Federal Regulations, 2011 CFR
2011-01-01
... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...
10 CFR 434.402 - Building envelope assemblies and materials.
Code of Federal Regulations, 2010 CFR
2010-01-01
... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...
10 CFR 434.402 - Building envelope assemblies and materials.
Code of Federal Regulations, 2013 CFR
2013-01-01
... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...
10 CFR 434.402 - Building envelope assemblies and materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...
10 CFR 434.402 - Building envelope assemblies and materials.
Code of Federal Regulations, 2014 CFR
2014-01-01
... MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Design Requirements-Electric Systems and Equipment... be determined with due consideration of all major series and parallel heat flow paths through the... thermal transmittance of opaque elements of assemblies shall be determined using a series path procedure...
NASA Astrophysics Data System (ADS)
Farid, V. L.; Wonorahardjo, S.
2018-05-01
The implementation of Green Building criteria is relatively new in architectural practice, especially in Indonesia. Consequently, the integration of these criteria into design process has the potential to change the design process itself. The implementation of the green building criteria into the conventional design process will be discussed in this paper. The concept of this project is to design a residential unit with a natural air-conditioning system. To achieve this purpose, the Green Building criteria has been implemented since the beginning of the design process until the detailing process on the end of the project. Several studies was performed throughout the design process, such as: (1) Conceptual review, where several professionally proved theories related to Tropical Architecture and passive design are used for a reference, and (2) Computer simulations, such as Computational Fluid Dynamics (CFD) and wind tunnel simulation, used to represent the dynamic response of the surrounding environment towards the building. Hopefully this paper may become a reference for designing a green residential building.
24 CFR 941.203 - Design and construction standards.
Code of Federal Regulations, 2013 CFR
2013-04-01
... national building code, such as Uniform Building Code, Council of American Building Officials Code, or Building Officials Conference of America Code; (2) Applicable State and local laws, codes, ordinances, and... intended to serve. Building design and construction shall strive to encourage in residents a proprietary...
7 CFR 4274.337 - Other regulatory requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...
7 CFR 4274.337 - Other regulatory requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...
24 CFR 941.203 - Design and construction standards.
Code of Federal Regulations, 2012 CFR
2012-04-01
... national building code, such as Uniform Building Code, Council of American Building Officials Code, or Building Officials Conference of America Code; (2) Applicable State and local laws, codes, ordinances, and... intended to serve. Building design and construction shall strive to encourage in residents a proprietary...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
7 CFR 4274.337 - Other regulatory requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
Assessing human exposure to power-frequency electric and magnetic fields.
Kaune, W T
1993-01-01
This paper reviews published literature and current problems relating to the assessment of occupational and residential human exposures to power-frequency electric and magnetic fields. Available occupational exposure data suggest that the class of job titles known as electrical workers may be an effective surrogate for time-weighted-average (TWA) magnetic-field (but not electric-field) exposure. Current research in occupational-exposure assessment is directed to the construction of job-exposure matrices based on electric- and magnetic-field measurements and estimates of worker exposures to chemicals and other factors of interest. Recent work has identified five principal sources of residential magnetic fields: electric power transmission lines, electric power distribution lines, ground currents, home wiring, and home appliances. Existing residential-exposure assessments have used one or more of the following techniques: questionnaires, wiring configuration coding, theoretical field calculations, spot electric- and magnetic-field measurements, fixed-site magnetic-field recordings, personal- exposure measurements, and geomagnetic-field measurements. Available normal-power magnetic-field data for residences differ substantially between studies. It is not known if these differences are due to geographical differences, differences in measurement protocols, or instrumentation differences. Wiring codes and measured magnetic fields (but not electric fields) are associated weakly. Available data suggest, but are far from proving, that spot measurements may be more effective than wire codes as predictors of long-term historical magnetic-field exposure. Two studies find that away-from-home TWA magnetic-field exposures are less variable than at-home exposures. The importance of home appliances as contributors to total residential magnetic-field exposure is not known at this time. It also is not known what characteristics (if any) of residential electric and magnetic fields are determinants of human health effects. PMID:8206021
10 CFR 435.7 - Water used to achieve energy efficiency. [Reserved
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Water used to achieve energy efficiency. [Reserved] 435.7 Section 435.7 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
USDA-ARS?s Scientific Manuscript database
A knowledge of different types of land cover in urban residential landscapes is important for building social and economic city-wide policies including landscape ordinances and water conservation programs. Urban landscapes are typically heterogeneous, so classification of land cover in these areas ...
RESIDENTIAL BUILDING ADAPTIVE ENERGY MANAGEMENT SYSTEM (R-BAEMS) DESIGN
The expected outcomes from Phase I included 1) a set of guidelines for implementing R-BAEMS in residential structures from both a retrofit and original design perspective and 2) a cost and energy analysis of R-BAEMS impact on the environment. The status of each of the outcomes...
77 FR 59899 - U.S. Multi-Sector Trade Mission to South India and Sri Lanka
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-01
... development of the residential and mixed use, tourism, and healthcare sectors, and encourage applications from... following text: Architecture Services Sub-Sectors [cir] Tourism [cir] Hospital and Healthcare [cir... broad need for all building types, especially for residential development, tourism and health facilities...
10 CFR 435.7 - Water used to achieve energy efficiency. [Reserved
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Water used to achieve energy efficiency. [Reserved] 435.7 Section 435.7 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
10 CFR 435.7 - Water used to achieve energy efficiency. [Reserved
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Water used to achieve energy efficiency. [Reserved] 435.7 Section 435.7 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
10 CFR 435.7 - Water used to achieve energy efficiency. [Reserved
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Water used to achieve energy efficiency. [Reserved] 435.7 Section 435.7 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2012 CFR
2012-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2013 CFR
2013-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2014 CFR
2014-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2011 CFR
2011-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
10 CFR 433.1 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-01-01
... FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS § 433.1 Purpose and scope. This part...-rise buildings, for which design for construction began on or after January 3, 2007, as required by...
10 CFR 433.1 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-01-01
... FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS § 433.1 Purpose and scope. This part...-rise buildings, for which design for construction began on or after January 3, 2007, as required by...
Guo, Bin; Huang, Jing; Guo, Xin-biao
2015-06-18
To evaluate the preventive effects of sound insulation windows on traffic noise. Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared. The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (P<0.05), which complied with the indoor noise level standards in our country. The closed or open states of the sound insulation windows had significant influence on the indoor noise levels (P<0.05). Compared with the open state of the sound insulation window, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads. Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.
Prevalence of Residential Dampness and Mold Exposure in a University Student Population
Lanthier-Veilleux, Mathieu; Généreux, Mélissa; Baron, Geneviève
2016-01-01
The impact of residential dampness or mold on respiratory health is well established but few studies have focused on university students. This study aims to: (a) describe the prevalence of exposure to residential dampness or mold in university students according to socio-geographic factors and (b) identify associated housing characteristics. A web survey was conducted in 2014 among the 26,676 students registered at the Université de Sherbrooke (QC, Canada). Residential dampness and mold being closely intertwined, they were considered as a single exposure and assessed using a validated questionnaire. Exposure was compared according to socio-geographic and housing characteristics using chi-square tests and logistic regressions. Among the 2097 participants included in the study (response rate: 8.1%), over 80% were tenants. Residential exposure to dampness or mold was frequent (36.0%, 95% CI: 33.9–38.1). Marked differences for this exposure were noted according to home ownership (39.7% vs. 25.5% among tenants and owners respectively; OR = 1.92%, 95% CI: 1.54–2.38). Campus affiliation, household composition and the number of residents per building were associated with exposure to dampness or mold (p < 0.01), while sex and age were not. Exposure was also associated with older buildings, and buildings in need of renovations and lacking proper ventilation (p < 0.001). This study highlights the potential risk of university students suffering from mold-related health effects given their frequent exposure to this agent. Further research is needed to fully evaluate the mold-related health impact in this at risk group. PMID:26861364
Residential Carpentry Series. Duty Task List.
ERIC Educational Resources Information Center
Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.
This document contains the occupational duty/task lists for nine occupations in the residential carpentry series. Each occupation is divided into a number of duties. A separate page for each duty in the occupation lists the tasks in that duty along with its code number and columns to indicate whether that particular duty has been taught and to…
THE EFFECTS OF BUILDING FEATURES ON INDOOR AIR AND POLLUTANT MOVEMENTS
The paper discusses full-scale residential building tests to determine the effects of building features on indoor air and pollutant movement. It was found that the activated heating and air-conditioning (HAC) system served as a conductor that enhanced the indoor air movement and ...
Liu, X P; Niu, J L; Kwok, K C S; Wang, J H; Li, B Z
2011-08-15
In this present work, the characteristics of hazardous gas dispersion and possible cross-unit contamination around a complex-shaped high-rise residential building due to wind effect are thoroughly studied using physical modeling method. Experiments were performed in a boundary layer wind tunnel for a 1:30 scale model that represented a 10-story residential building in prototype. Tracer gas, simulating exhausted room air, was continuously released from different floor levels, and its concentrations on the adjacent envelope surfaces were measured using fast flame ionization detectors. The mean concentration fields were reported and analyzed under different configurations during the experiment to consider the effects on pollutant dispersion behavior due to changes in source position and approaching wind condition, with the main emphasis on the differences between open-window and closed-window conditions. In particular, the measured concentration fields were further examined from a practical point of view, with respect to hazard assessment. Understanding these hazardous plume dispersion features is useful for employing effective intervention strategies in modern residential building environment in case of hazardous substance release. The study on this physical process is not only helpful to reduce the hazardous effect of routine release of harmful pollutant near the building, but also useful for the purpose of prevention and control of accidental infectious diseases outbreak. Copyright © 2011 Elsevier B.V. All rights reserved.
An international survey of building energy codes and their implementation
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
2017-08-01
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
An international survey of building energy codes and their implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konopacki, S.; Akbari, H.; Gartland, L.
The U.S. Environmental Protection Agency (EPA) sponsored this project to estimate potential energy and monetary savings resulting from the implementation of light-colored roofs on residential and commercial buildings in major U.S. metropolitan areas. Light-colored roofs reflect more sunlight than dark roofs, so they keep buildings cooler and reduce air-conditioning demand. Typically, rooftops in the United States are dark, and thus there is a potential for saving energy and money by changing to reflective roofs. Naturally, the expected savings are higher in southern, sunny, and cloudless climates. In this study, we make quantitative estimates of reduction in peak power demand andmore » annual cooling electricity use that would result from increasing the reflectivity of the roofs. Since light-colored roofs also reflect heat in the winter, the estimates of annual electricity savings are a net value corrected for the increased wintertime energy use. Savings estimates only include direct reduction in building energy use and do not account for the indirect benefit that would also occur from the reduction in ambient temperature, i.e. a reduction in the heat island effect. This analysis is based on simulations of building energy use, using the DOE-2 building energy simulation program. Our methodology starts with specifying 11 prototypical buildings: single-family residential (old and new), office (old and new), retail store (old and new), school (primary and secondary), health (hospital and nursing home), and grocery store. Most prototypes are simulated with two heating systems: gas furnace and heat pumps. We then perform DOE-2 simulations of the prototypical buildings, with light and dark roofs, in a variety of climates and obtain estimates of the energy use for air conditioning and heating.« less
Determinants of the Safety Performance of Private Multi-Storey Residential Buildings in Hong Kong
ERIC Educational Resources Information Center
Yau, Yung; Ho, Daniel Chi Wing; Chau, Kwong Wing
2008-01-01
Given the high population and development density in Hong Kong, building failures can result in catastrophic consequences. It is thus worthwhile identifying those dilapidated buildings, and this explains why the Hong Kong government has considered launching a mandatory building inspection scheme in the city. Apart from the measurement of building…
Building Energy Asset Score for Building Owners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Building Technologies Office
2015-01-01
The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for building owners.
[Carbon monoxide poisoning by a heating system].
Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus
2016-01-01
A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.
Improving Building Energy Simulation Programs Through Diagnostic Testing (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2012-02-01
New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market. Reducing the energy use of existing homes in the United States offers significant energy-saving opportunities, which can be identified through building simulation software tools that calculate optimal packages of efficiency measures. To improve the accuracy of energy analysis for residential buildings, the National Renewable Energy Laboratory's (NREL) Buildings Research team developed the Building Energy Simulation Test for Existing Homes (BESTEST-EX), a method for diagnosing and correcting errors in building energy audit software and calibration procedures. BESTEST-EX consists of building physics and utility billmore » calibration test cases, which software developers can use to compare their tools simulation findings to reference results generated with state-of-the-art simulation tools. Overall, the BESTEST-EX methodology: (1) Tests software predictions of retrofit energy savings in existing homes; (2) Ensures building physics calculations and utility bill calibration procedures perform to a minimum standard; and (3) Quantifies impacts of uncertainties in input audit data and occupant behavior. BESTEST-EX is helping software developers identify and correct bugs in their software, as well as develop and test utility bill calibration procedures.« less