Chandra High Resolution Camera (HRC). Rev. 59
NASA Technical Reports Server (NTRS)
Murray, Stephen
2004-01-01
This monthly report discusses management and general status, mission support and operations, and science activities. A technical memorandum entitled "Failure Analysis of HRC Flight Relay" is included with the report.
NASA Astrophysics Data System (ADS)
Gonzaga, S.; et al.
2011-03-01
ACS was designed to provide a deep, wide-field survey capability from the visible to near-IR using the Wide Field Camera (WFC), high resolution imaging from the near-UV to near-IR with the now-defunct High Resolution Camera (HRC), and solar-blind far-UV imaging using the Solar Blind Camera (SBC). The discovery efficiency of ACS's Wide Field Channel (i.e., the product of WFC's field of view and throughput) is 10 times greater than that of WFPC2. The failure of ACS's CCD electronics in January 2007 brought a temporary halt to CCD imaging until Servicing Mission 4 in May 2009, when WFC functionality was restored. Unfortunately, the high-resolution optical imaging capability of HRC was not recovered.
Chandra's Ultimate Angular Resolution: Studies of the HRC-I Point Spread Function
NASA Astrophysics Data System (ADS)
Juda, Michael; Karovska, M.
2010-03-01
The Chandra High Resolution Camera (HRC) should provide an ideal imaging match to the High-Resolution Mirror Assembly (HRMA). The laboratory-measured intrinsic resolution of the HRC is 20 microns FWHM. HRC event positions are determined via a centroiding method rather than by using discrete pixels. This event position reconstruction method and any non-ideal performance of the detector electronics can introduce distortions in event locations that, when combined with spacecraft dither, produce artifacts in source images. We compare ray-traces of the HRMA response to "on-axis" observations of AR Lac and Capella as they move through their dither patterns to images produced from filtered event lists to characterize the effective intrinsic PSF of the HRC-I. A two-dimensional Gaussian, which is often used to represent the detector response, is NOT a good representation of the intrinsic PSF of the HRC-I; the actual PSF has a sharper peak and additional structure which will be discussed. This work was supported under NASA contract NAS8-03060.
Research relative to high resolution camera on the advanced X-ray astrophysics facility
NASA Technical Reports Server (NTRS)
1986-01-01
The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.
The PanCam instrument on the 2018 Exomars rover: Scientific objectives
NASA Astrophysics Data System (ADS)
Jaumann, Ralf; Coates, Andrew; Hauber, Ernst; Hoffmann, Harald; Schmitz, Nicole; Le Deit, Laetitia; Tirsch, Daniela; Paar, Gerhard; Griffiths, Andrew
2010-05-01
The Exomars Panoramic Camera System is an imaging suite of three camera heads to be mounted on the ExoMars rover`s mast, with the boresight 1.8 m above ground. As late as the ExoMars Pasteur Payload Design Review (PDR) in 2009, the PanCam consists of two identical wide angle cameras (WAC) with fixed focal length lenses, and a high resolution camera (HRC) with an automatic focus mechanism, placed adjacent to the right WAC. The WAC stereo pair provides binocular vision for stereoscopic studies as well as 12 filter positions (per camera) for stereoscopic colour imaging and scientific multispectral studies. The stereo baseline of the pair is 500 mm. The two WAC have 22 mm focal length, f/10 lenses that illuminate detectors with 1024 × 1024 pixels. WAC lenses are fixed, with an optimal focus set to 4 m, and a focus ranging from 1.2 m (corresponding to the nearest view of the calibration target on the rover deck) to infinity. The HRC is able to focus between 0.9 m (distance to a drill core on the rover`s sample tray) and infinity. The instantaneous field of views of WAC and HRC are 580 μrad/pixel and 83 μrad/pixel, respectively. The corresponding resolution (in mm/pixel) at a distance of 2 m are 1.2 (WAC) and 0.17 (HRC), at 100 m distance it is 58 (WAC) and 8.3 (HRC). WAC and HRC will be geometrically co-aligned. The main scientific goal of PanCam is the geologic characterisation of the environment in which the rover is operating, providing the context for investigations carried out by the other instruments of the Pasteur payload. PanCam data will serve as a bridge between orbital data (high-resolution images from HRSC, CTX, and HiRISE, and spectrometer data from OMEGA and CRISM) and the data acquired in situ on the Martian surface. The position of HRC on top of the rover`s mast enables the detailed panoramic inspection of surface features over the full horizontal range of 360° even at large distances, an important prerequisite to identify the scientifically most promising targets and to plan the rover`s traverse. Key to success of PanCam is the provision of data that allow the determination of rock lithology, either of boulders on the surface or of outcrops. This task requires high spatial resolution as well as colour capabilities. The stereo images provide complementary information on the three-dimensional properties (i.e. the shape) of rocks. As an example, the degree of rounding of rocks as a result of fluvial transport can reveal the erosional history of the investigated particles, with possible implications on the chronology and intensity of rock-water interaction. The identification of lithology and geological history of rocks will strongly benefit from the co-aligned views of WAC (colour, stereo) and HRC (high spatial resolution), which will ensure that 3D and multispectral information is available together with fine-scale textural information for each scene. Stereo information is also of utmost importance for the determination of outcrop geometry (e.g., strike and dip of layered sequences), which helps to understand the emplacement history of sedimentary and volcanic rocks (e.g., cross-bedding, unconformities, etc.). PanCam will further reveal physical soil properties such as cohesion by imaging sites where the soil is disturbed by the rover`s wheels and the drill. Another essential task of PanCam is the imaging of samples (from the drill) before ingestion into the rover for further analysis by other instruments. PanCam can be tilted vertically and will also study the atmosphere (e.g., dust loading, opacity, clouds) and aeolian processes related to surface-atmosphere interactions, such as dust devils.
Advanced Camera for Surveys Instrument Handbook for Cycle 25 v. 16.0
NASA Astrophysics Data System (ADS)
Avila, R. J.
2017-01-01
The Advanced Camera for Surveys (ACS), a third-generation instrument, was installed in the Hubble Space Telescope during Servicing Mission 3B, on March 7, 2002. Its primary purpose was to increase HST imaging discovery efficiency by about a factor of 10, with a combination of detector area and quantum efficiency that surpasses previous instruments. ACS has three independent cameras that have provided wide-field, high resolution, and ultraviolet imaging capabilities respectively, using a broad assortment of filters designed to address a large range of scientific goals. In addition, coronagraphic, polarimetric, and grism capabilities have made the ACS a versatile and powerful instrument. The ACS Instrument Handbook, which is maintained by the ACS Team at STScI, descr ibes the instrument properties, performance, operations, and calibration. It is the basic technical reference manual for the instrument, and should be used with other documents (listed in Table 1.1) for writing Phase I proposals, detailed Phase II programs, and for data analysis. (See Figure 1.1). In May 2009, Servicing Mission 4 (SM4) successfully restored the ACS Wide Field Camera (WFC) to regular service after its failure in January 2007. Unfortunately, the ACS High Resolution Camera (HRC) was not restored to operation during SM4, so it cannot be proposed for new observations. Nevertheless, this handbook retains description of the HRC to support analysis of archived observations. The ACS Solar Blind Channel (SBC) was unaffected by the January 2007 failure of WFC and HRC. The SBC has remained in steady operation, and was not serviced during SM4. It remains available for new observations.
Deconvolving the Nucleus of Centaurus A Using Chandra PSF Library
NASA Technical Reports Server (NTRS)
Karovska, Margarita
2000-01-01
Centaurus A (NGC 5128) is a giant early-type galaxy containing the nearest (at 3.5 Mpc) radio-bright Active Galactic Nucleus (AGN). Cen A was observed with the High Resolution Camera (HRC) on the Chandra X-ray Observatory on several occasions since the launch in July 1999. The high-angular resolution (less than 0.5 arcsecond) Chandra/HRC images reveal X ray multi-scale structures in this object with unprecedented detail and clarity, including the bright nucleus believed to be associated with a supermassive black hole. We explored the spatial extent of the Cen A nucleus using deconvolution techniques on the full resolution Chandra images. Model point spread functions (PSFs) were derived from the standard Chandra raytrace PSF library as well as unresolved point sources observed with Chandra. The deconvolved images show that the Cen A nucleus is resolved and asymmetric. We discuss several possible causes of this extended emission and of the asymmetries.
The Panoramic Camera (PanCam) Instrument for the ESA ExoMars Rover
NASA Astrophysics Data System (ADS)
Griffiths, A.; Coates, A.; Jaumann, R.; Michaelis, H.; Paar, G.; Barnes, D.; Josset, J.
The recently approved ExoMars rover is the first element of the ESA Aurora programme and is slated to deliver the Pasteur exobiology payload to Mars by 2013. The 0.7 kg Panoramic Camera will provide multispectral stereo images with 65° field-of- view (1.1 mrad/pixel) and high resolution (85 µrad/pixel) monoscopic "zoom" images with 5° field-of-view. The stereo Wide Angle Cameras (WAC) are based on Beagle 2 Stereo Camera System heritage. The Panoramic Camera instrument is designed to fulfil the digital terrain mapping requirements of the mission as well as providing multispectral geological imaging, colour and stereo panoramic images, solar images for water vapour abundance and dust optical depth measurements and to observe retrieved subsurface samples before ingestion into the rest of the Pasteur payload. Additionally the High Resolution Camera (HRC) can be used for high resolution imaging of interesting targets detected in the WAC panoramas and of inaccessible locations on crater or valley walls.
Chandra's Darkest Bright Star: not so Dark after All?
NASA Astrophysics Data System (ADS)
Ayres, Thomas R.
2008-11-01
The Chandra High Resolution camera (HRC) has obtained numerous short exposures of the ultraviolet (UV)-bright star Vega (α Lyrae; HD 172167: A0 V), to calibrate the response of the detector to out-of-band (non-X-ray) radiation. A new analysis uncovered a stronger "blue leak" in the imaging section (HRC-I) than reported in an earlier study of Vega based on a subset of the pointings. The higher count rate—a factor of nearly 2 above prelaunch estimates—raised the possibility that genuine coronal X-rays might lurk among the out-of-band events. Exploiting the broader point-spread function of the UV leak compared with soft X-rays identified an excess of counts centered on the target, technically at 3σ significance. A number of uncertainties, however, prevent a clear declaration of a Vegan corona. A more secure result would be within reach of a deep uninterrupted HRC-I pointing.
NASA Astrophysics Data System (ADS)
Griffiths, Andrew; Coates, Andrew; Muller, Jan-Peter; Jaumann, Ralf; Josset, Jean-Luc; Paar, Gerhard; Barnes, David
2010-05-01
The ExoMars mission has evolved into a joint European-US mission to deliver a trace gas orbiter and a pair of rovers to Mars in 2016 and 2018 respectively. The European rover will carry the Pasteur exobiology payload including the 1.56 kg Panoramic Camera. PanCam will provide multispectral stereo images with 34 deg horizontal field-of-view (580 microrad/pixel) Wide-Angle Cameras (WAC) and (83 microrad/pixel) colour monoscopic "zoom" images with 5 deg horizontal field-of-view High Resolution Camera (HRC). The stereo Wide Angle Cameras (WAC) are based on Beagle 2 Stereo Camera System heritage [1]. Integrated with the WACs and HRC into the PanCam optical bench (which helps the instrument meet its planetary protection requirements) is the PanCam interface unit (PIU); which provides image storage, a Spacewire interface to the rover and DC-DC power conversion. The Panoramic Camera instrument is designed to fulfil the digital terrain mapping requirements of the mission [2] as well as providing multispectral geological imaging, colour and stereo panoramic images and solar images for water vapour abundance and dust optical depth measurements. The High Resolution Camera (HRC) can be used for high resolution imaging of interesting targets detected in the WAC panoramas and of inaccessible locations on crater or valley walls. Additionally HRC will be used to observe retrieved subsurface samples before ingestion into the rest of the Pasteur payload. In short, PanCam provides the overview and context for the ExoMars experiment locations, required to enable the exobiology aims of the mission. In addition to these baseline capabilities further enhancements are possible to PanCam to enhance it's effectiveness for astrobiology and planetary exploration: 1. Rover Inspection Mirror (RIM) 2. Organics Detection by Fluorescence Excitation (ODFE) LEDs [3-6] 3. UVIS broadband UV Flux and Opacity Determination (UVFOD) photodiode This paper will discuss the scientific objectives and resource impacts of these enhancements. References: 1. Griffiths, A.D., Coates, A.J., Josset, J.-L., Paar, G., Hofmann, B., Pullan, D., Ruffer, P., Sims, M.R., Pillinger, C.T., The Beagle 2 stereo camera system, Planet. Space Sci. 53, 1466-1488, 2005. 2. Paar, G., Oberst, J., Barnes, D.P., Griffiths, A.D., Jaumann, R., Coates, A.J., Muller, J.P., Gao, Y., Li, R., 2007, Requirements and Solutions for ExoMars Rover Panoramic Camera 3d Vision Processing, abstract submitted to EGU meeting, Vienna, 2007. 3. Storrie-Lombardi, M.C., Hug, W.F., McDonald, G.D., Tsapin, A.I., and Nealson, K.H. 2001. Hollow cathode ion lasers for deep ultraviolet Raman spectroscopy and fluorescence imaging. Rev. Sci. Ins., 72 (12), 4452-4459. 4. Nealson, K.H., Tsapin, A., and Storrie-Lombardi, M. 2002. Searching for life in the universe: unconventional methods for an unconventional problem. International Microbiology, 5, 223-230. 5. Mormile, M.R. and Storrie-Lombardi, M.C. 2005. The use of ultraviolet excitation of native fluorescence for identifying biomarkers in halite crystals. Astrobiology and Planetary Missions (R. B. Hoover, G. V. Levin and A. Y. Rozanov, Eds.), Proc. SPIE, 5906, 246-253. 6. Storrie-Lombardi, M.C. 2005. Post-Bayesian strategies to optimize astrobiology instrument suites: lessons from Antarctica and the Pilbara. Astrobiology and Planetary Missions (R. B. Hoover, G. V. Levin and A. Y. Rozanov, Eds.), Proc. SPIE, 5906, 288-301.
Distant Supernova Remnant Imaged by Chandra's High Resolution Camera
NASA Astrophysics Data System (ADS)
1999-09-01
The High Resolution Camera (HRC), one of the two X-ray cameras on NASA's Chandra X-ray Observatory, was placed into the focus for the first time on Monday, August 30. The first target was LMC X-1, a point-like source of X rays in the Large Magellanic Cloud. The Large Magellanic Cloud, a companion galaxy to the Milky Way, is 160,000 light years from Earth. After checking the focus with LMC X-1, Chandra observed N132D, a remnant of an exploded star in the Large Magellanic Cloud. "These were preliminary test observations," emphasized Dr. Stephen Murray, of the Harvard-Smithsonian Center for Astrophysics, principal investigator for the High Resolution Camera. "But we are very pleased with the results. All indications are that the HRC will produce X-ray images of unprecedented clarity." The N132D image shows a highly structured remnant, or shell, of 10-million-degree gas that is 80 light years across. Such a shell in the vicinity of the Sun would encompass more than fifty nearby stars. The amount of material in the N132D hot gas remnant is equal to that of 600 suns. The N132D supernova remnant appears to be colliding with a giant molecular cloud, which produces the brightening on the southern rim of the remnant. The molecular cloud, visible with a radio telescope, has the mass of 300,000 suns. The relatively weak x-radiation on the upper left shows that the shock wave is expanding into a less dense region on the edge of the molecular cloud. A number of small circular structures are visible in the central regions and a hint of a large circular loop can be seen in the upper part of the remnant. Whether the peculiar shape of the supernova remnant can be fully explained in terms of these effects, or whether they point to a peculiar cylindrically shaped explosion remains to be seen. -more- "The image is so rich in structure that it will take a while to sort out what is really going on," Murray said. "It could be multiple supernovas, or absorbing clouds in the vicinity of the supernova." The unique capabilities of the HRC stem from the close match of its imaging capability to the focusing power of the mirrors. When used with the Chandra mirrors, the HRC will make images that reveal detail as small as one-half an arc second. This is equivalent to the ability to read a stop sign at a distance of twelve miles. The checkout period for the HRC will continue for the next few weeks, during which time the team expects to acquire images of other supernova remnants, star clusters, and starburst galaxies. To follow Chandra's progress, visit the Chandra News Web site at: http://chandra.harvard.edu AND http://chandra.nasa.gov NASA's Marshall Space Flight Center in Huntsville, Alabama, manages the Chandra X-ray Observatory for NASA's Office of Space Science, NASA Headquarters, Washington, D.C. The Smithsonian Astrophysical Observatory's Chandra X-ray Center in Cambridge, Mass., manages the Chandra science program and controls the observatory for NASA. TRW Space and Electronics Group of Redondo Beach, Calif., leads the contractor team that built Chandra. High resolution digital versions of the X-ray image (300 dpi JPG, TIFF) and other information associated with this release are available on the Internet at: http://chandra.harvard.edu/photo/0050/ or via links in: http://chandra.harvard.edu
VizieR Online Data Catalog: HST photometry of stars in HD 97950 (Pang+, 2016)
NASA Astrophysics Data System (ADS)
Pang, X.; Pasquali, A.; Grebel, E. K.
2016-07-01
The HD97950 cluster and its immediate surroundings in the giant HII region NGC3603 were observed with the Hubble Space Telescope (HST). The ultraviolet (UV) data were taken with the High Resolution Channel (HRC) of the Advanced Camera for Surveys (ACS) in 2005 (GO 10602, PI: Jesus Maiz Apellaniz) through the F220W, F250W, F330W, and F435W filters. The HRC is characterized by a spatial resolution of 0.03"/pixel and a field of view of 29''*25''. The optical observations were carried out with the Wide Field and Planetary Camera 2 (WFPC2) in two epochs: 1997 (GO 6763, PI: Laurent Drissen) and 2007 (GO 11193, PI: Wolfgang Brandner) through the F555W, F675W, and F814W filters. The Planetary Camera (PC) chip was centered on the cluster (0.045"/pixel, 40''*40'') for both programs. Pang et al. 2013 (cat. J/ApJ/764/73) reduced the two-epoch WFPC2 data and identified more than 400 member stars on the PC chip via relative proper motions. Of these member stars, 142 are in common between the HRC and PC images and thus have UV and optical photometry available (see Table1). Among the HD97950 cluster member stars determined from relative proper motions (Pang et al. 2013, cat. J/ApJ/764/73, Table2), there are five main-sequence (MS) stars located in the cluster with projected distances of r<0.7pc from the center, for which there are also spectral types available from Table3 of Melena et al. (2008AJ....135..878M). The photometry of these five MS stars is presented in Table2. The individual color excesses and extinctions of the member main sequence stars are listed in Table3. (3 data files).
The Chandra HRC View of the Subarcsecond Structures in the Nuclear Region of NGC 1068
NASA Astrophysics Data System (ADS)
Wang, Junfeng; Fabbiano, Giuseppina; Karovska, Margarita; Elvis, Martin; Risaliti, Guido
2012-09-01
We have obtained a high spatial resolution X-ray image of the nucleus of NGC 1068 using the High Resolution Camera (HRC-I) on board the Chandra X-ray Observatory, which provides an unprecedented view of the innermost 1 arcsec radius region of this galaxy. The HRC image resolves the narrow-line region into X-ray emission clumps matching bright emission-line clouds in the HST [OIII] λ5007 images and allows comparison with subarcsecond-scale radio jet for the first time. Two distinct X-ray knots are revealed at 1.3-1.4 arcsec northeast and southwest of the nucleus. Based on the combined X-ray, [O III], and radio continuum morphology, we identify the locations of intense radio jet-cloud interaction. The [O III] to soft X-ray ratios show that some of these clouds are strongly affected by shock heating, whereas in other locations the jet simply thrusts through with no signs of strong interaction. This is further strengthened by the presence of a kT ~ 1 keV collisionally ionized component in the ACIS spectrum of a shock-heated cloud HST-G. We estimate that the kinematic luminosity of the jet-driven shocks is 6 × 1038 erg s-1, a negligible fraction (10-4) of the estimated total jet power.
History of Chandra X-Ray Observatory
1997-03-16
This photo shows the High Resolution Camera (HRC) for the Chandra X-Ray Observatory (CXO), formerly Advanced X-Ray Astrophysics Facility (AXAF), being integrated with the High Resolution Mirror Assembly (HRMA) in Marshall Space Flight Center's (MSFC's) 24-foot Vacuum Chamber at the X-Ray Calibration Facility (XRCF). The AXAF was renamed CXO in 1999. The CXO is the most sophisticated and the world's most poweful x-ray telescope ever built. It observes x-rays from high-energy regions of the universe, such as hot gas in the remnants of exploded stars. The HRC is one of the two instruments used at the focus of CXO, where it will detect x-rays reflected from an assembly of eight mirrors. The unique capabilities of the HRC stem from the close match of its imaging capability to the focusing of the mirrors. When used with CXO mirrors, the HRC makes images that reveal detail as small as one-half an arc second. This is equivalent to the ability to read a newspaper at a distance of 1 kilometer. MSFC's XRCF is the world's largest, most advanced laboratory for simulating x-ray emissions from distant celestial objects. It produces a space-like environment in which components relatedto x-ray telescope imaging are tested and the quality of their performances in space is predicted. TRW, Inc. was the prime contractor for the development of the CXO and NASA's MSFC was responsible for its project management. The Smithsonian Astrophysical Observatory controls science and flight operations of the CXO for NASA from Cambridge, Massachusetts. The CXO was launched July 22, 1999 aboard the Space Shuttle Columbia (STS-93).
History of Chandra X-Ray Observatory
1997-03-16
This photo shows the High Resolution Camera (HRC) for the Chandra X-Ray Observatory (CXO), formerly Advanced X-Ray Astrophysics Facility (AXAF), being integrated with the High Resolution Mirror Assembly (HRMA) in Marshall Space Flight Center's (MSFC's) 24-foot Vacuum Chamber at the X-Ray Calibration Facility (XRCF). The AXAF was renamed CXO in 1999. The CXO is the most sophisticated and the world's most powerful x-ray telescope ever built. It observes x-rays from high-energy regions of the universe, such as hot gas in the remnants of exploded stars. The HRC is one of the two instruments used at the focus of CXO, where it will detect x-rays reflected from an assembly of eight mirrors. The unique capabilities of the HRC stem from the close match of its imaging capability to the focusing of the mirrors. When used with CXO mirrors, the HRC makes images that reveal detail as small as one-half an arc second. This is equivalent to the ability to read a newspaper at a distance of 1 kilometer. MSFC's XRCF is the world's largest, most advanced laboratory for simulating x-ray emissions from distant celestial objects. It produces a space-like environment in which components related to x-ray telescope imaging are tested and the quality of their performances in space is predicted. TRW, Inc. was the prime contractor for the development of the CXO and NASA's MSFC was responsible for its project management. The Smithsonian Astrophysical Observatory controls science and flight operations of the CXO for NASA from Cambridge, Massachusetts. The CXO was launched July 22, 1999 aboard the Space Shuttle Columbia (STS-93).
Panoramic 3d Vision on the ExoMars Rover
NASA Astrophysics Data System (ADS)
Paar, G.; Griffiths, A. D.; Barnes, D. P.; Coates, A. J.; Jaumann, R.; Oberst, J.; Gao, Y.; Ellery, A.; Li, R.
The Pasteur payload on the ESA ExoMars Rover 2011/2013 is designed to search for evidence of extant or extinct life either on or up to ˜2 m below the surface of Mars. The rover will be equipped by a panoramic imaging system to be developed by a UK, German, Austrian, Swiss, Italian and French team for visual characterization of the rover's surroundings and (in conjunction with an infrared imaging spectrometer) remote detection of potential sample sites. The Panoramic Camera system consists of a wide angle multispectral stereo pair with 65° field-of-view (WAC; 1.1 mrad/pixel) and a high resolution monoscopic camera (HRC; current design having 59.7 µrad/pixel with 3.5° field-of-view) . Its scientific goals and operational requirements can be summarized as follows: • Determination of objects to be investigated in situ by other instruments for operations planning • Backup and Support for the rover visual navigation system (path planning, determination of subsequent rover positions and orientation/tilt within the 3d environment), and localization of the landing site (by stellar navigation or by combination of orbiter and ground panoramic images) • Geological characterization (using narrow band geology filters) and cartography of the local environments (local Digital Terrain Model or DTM). • Study of atmospheric properties and variable phenomena near the Martian surface (e.g. aerosol opacity, water vapour column density, clouds, dust devils, meteors, surface frosts,) 1 • Geodetic studies (observations of Sun, bright stars, Phobos/Deimos). The performance of 3d data processing is a key element of mission planning and scientific data analysis. The 3d Vision Team within the Panoramic Camera development Consortium reports on the current status of development, consisting of the following items: • Hardware Layout & Engineering: The geometric setup of the system (location on the mast & viewing angles, mutual mounting between WAC and HRC) needs to be optimized w.r.t. fields of view, ranging capability (distance measurement capability), data rate, necessity of calibration targets, hardware & data interfaces to other subsystems (e.g. navigation) as well as accuracy impacts of sensor design and compression ratio. • Geometric Calibration: The geometric properties of the individual cameras including various spectral filters, their mutual relations and the dynamic geometrical relation between rover frame and cameras - with the mast in between - are precisely described by a calibration process. During surface operations these relations will be continuously checked and updated by photogrammetric means, environmental influences such as temperature, pressure and the Mars gravity will be taken into account. • Surface Mapping: Stereo imaging using the WAC stereo pair is used for the 3d reconstruction of the rover vicinity to identify, locate and characterize potentially interesting spots (3-10 for an experimental cycle to be performed within approx. 10-30 sols). The HRC is used for high resolution imagery of these regions of interest to be overlaid on the 3d reconstruction and potentially refined by shape-from-shading techniques. A quick processing result is crucial for time critical operations planning, therefore emphasis is laid on the automatic behaviour and intrinsic error detection mechanisms. The mapping results will be continuously fused, updated and synchronized with the map used by the navigation system. The surface representation needs to take into account the different resolutions of HRC and WAC as well as uncommon or even unexpected image acquisition modes such as long range, wide baseline stereo from different rover positions or escape strategies in the case of loss of one of the stereo camera heads. • Panorama Mosaicking: The production of a high resolution stereoscopic panorama nowadays is state-of-art in computer vision. However, certain 2 challenges such as the need for access to accurate spherical coordinates, maintenance of radiometric & spectral response in various spectral bands, fusion between HRC and WAC, super resolution, and again the requirement of quick yet robust processing will add some complexity to the ground processing system. • Visualization for Operations Planning: Efficient operations planning is directly related to an ergonomic and well performing visualization. It is intended to adapt existing tools to an integrated visualization solution for the purpose of scientific site characterization, view planning and reachability mapping/instrument placement of pointing sensors (including the panoramic imaging system itself), and selection of regions of interest. The main interfaces between the individual components as well as the first version of a user requirement document are currently under definition. Beside the support for sensor layout and calibration the 3d vision system will consist of 2-3 main modules to be used during ground processing & utilization of the ExoMars Rover panoramic imaging system. 3
VizieR Online Data Catalog: HST observations of star clusters in NGC 3256 (Mulia+, 2016)
NASA Astrophysics Data System (ADS)
Mulia, A. J.; Chandar, R.; Whitmore, B. C.
2016-09-01
Our observations come from the ACS on Hubble Space Telescope (HST). NGC 3256 was observed using the filters F555W (~V in the Johnson-Cousins system; exposed for 2552s), FR656N (Hα; 2552s), and F330W (~U; 11358s) as part of the program GO-9735 (PI: Whitmore). The V and U band images were taken in 2003 November using the Wide Field Camera (WFC) and High Resolution Camera (HRC), respectively. The Hα observations were taken in 2004 March. WFC observations using F435W (~B) and F814W (~I) filters were taken in 2005 November as part of program GO-10592 (PI: Evans) for 1320 and 760s, respectively. (1 data file).
The PanCam Instrument for the ExoMars Rover
NASA Astrophysics Data System (ADS)
Coates, A. J.; Jaumann, R.; Griffiths, A. D.; Leff, C. E.; Schmitz, N.; Josset, J.-L.; Paar, G.; Gunn, M.; Hauber, E.; Cousins, C. R.; Cross, R. E.; Grindrod, P.; Bridges, J. C.; Balme, M.; Gupta, S.; Crawford, I. A.; Irwin, P.; Stabbins, R.; Tirsch, D.; Vago, J. L.; Theodorou, T.; Caballo-Perucha, M.; Osinski, G. R.; PanCam Team
2017-07-01
The scientific objectives of the ExoMars rover are designed to answer several key questions in the search for life on Mars. In particular, the unique subsurface drill will address some of these, such as the possible existence and stability of subsurface organics. PanCam will establish the surface geological and morphological context for the mission, working in collaboration with other context instruments. Here, we describe the PanCam scientific objectives in geology, atmospheric science, and 3-D vision. We discuss the design of PanCam, which includes a stereo pair of Wide Angle Cameras (WACs), each of which has an 11-position filter wheel and a High Resolution Camera (HRC) for high-resolution investigations of rock texture at a distance. The cameras and electronics are housed in an optical bench that provides the mechanical interface to the rover mast and a planetary protection barrier. The electronic interface is via the PanCam Interface Unit (PIU), and power conditioning is via a DC-DC converter. PanCam also includes a calibration target mounted on the rover deck for radiometric calibration, fiducial markers for geometric calibration, and a rover inspection mirror.
Application of Sensor Fusion to Improve Uav Image Classification
NASA Astrophysics Data System (ADS)
Jabari, S.; Fathollahi, F.; Zhang, Y.
2017-08-01
Image classification is one of the most important tasks of remote sensing projects including the ones that are based on using UAV images. Improving the quality of UAV images directly affects the classification results and can save a huge amount of time and effort in this area. In this study, we show that sensor fusion can improve image quality which results in increasing the accuracy of image classification. Here, we tested two sensor fusion configurations by using a Panchromatic (Pan) camera along with either a colour camera or a four-band multi-spectral (MS) camera. We use the Pan camera to benefit from its higher sensitivity and the colour or MS camera to benefit from its spectral properties. The resulting images are then compared to the ones acquired by a high resolution single Bayer-pattern colour camera (here referred to as HRC). We assessed the quality of the output images by performing image classification tests. The outputs prove that the proposed sensor fusion configurations can achieve higher accuracies compared to the images of the single Bayer-pattern colour camera. Therefore, incorporating a Pan camera on-board in the UAV missions and performing image fusion can help achieving higher quality images and accordingly higher accuracy classification results.
Zambrana-García, José Luis; Montoro-Caba, María Isabel; Chicano-Gallardo, Maite; Monrobel-Lancho, Ana; Pérez-de-Luque, Daniel Jesús; Peña-Ojeda, José Antonio; Recio-Ramírez, José Manuel
2016-01-01
By high resolution consultation (HRC) we mean an ambulatory process of assistance fulfilled in a single day, by which treatment and diagnosis are established and recorded. To assess to which extent patients with digestive conditions may benefit from a single consultation system. A descriptive study of 179 first visit events, randomly selected as high-resolution consultations in gastroenterology. We discuss the percentage of patients who benefited from HRC and the complementary tests performed. Most common conditions included dyspepsia (16%), a family history of colon cancer (16%) and gastroesophageal reflux disease (GERD) (16%). Seventy-nine (44%) of all first visits became HRCs and 80 (45%) required a diagnostic test (100% abdominal ultrasound) that was reviewed on the same day. Performing a test on the same day significantly increased the percentage of HRCs (57% vs. 34%, p < 0.002). GERD, dyspepsia, cholelithiasis and chronic liver disease were the subjects most commonly leading to HRC. Gastroenterology consultations may largely benefit from an HRC system with only organizational changes and no additional costs.
Discovery of X-Ray Emission from the Crab Pulsar at Pulse Minimum
NASA Technical Reports Server (NTRS)
Tennant, Allyn F.; Becker, Werner; Juda, Michael X.; Elsner, Ronald F.; Kolodziejczak, Jeffery J.; Murray, Stephen S.; ODell, Stephen L.; Paerels, Frits; Swartz, Douglas A.; Shibazaki, Noriaki;
1999-01-01
The Chandra X-ray Observatory observed the Crab Nebula and Pulsar using the Low-Energy Transmission Grating (LETG) with the High-Resolution Camera (HRC). Time-resolved zeroth-order images reveal that the pulsar emits x rays at all pulse phases. Analysis of the flux at minimum -- most likely nonthermal in origin -- places an upper limit (T(sub infinity) < 2.1 MK) on the surface temperature of the underlying neutron star. In addition, analysis of the pulse profile appears to confirm the absolute timing of the Observatory to within about 0.2 ms.
The PanCam Instrument for the ExoMars Rover
Coates, A.J.; Jaumann, R.; Griffiths, A.D.; Leff, C.E.; Schmitz, N.; Josset, J.-L.; Paar, G.; Gunn, M.; Hauber, E.; Cousins, C.R.; Cross, R.E.; Grindrod, P.; Bridges, J.C.; Balme, M.; Gupta, S.; Crawford, I.A.; Irwin, P.; Stabbins, R.; Tirsch, D.; Vago, J.L.; Theodorou, T.; Caballo-Perucha, M.; Osinski, G.R.
2017-01-01
Abstract The scientific objectives of the ExoMars rover are designed to answer several key questions in the search for life on Mars. In particular, the unique subsurface drill will address some of these, such as the possible existence and stability of subsurface organics. PanCam will establish the surface geological and morphological context for the mission, working in collaboration with other context instruments. Here, we describe the PanCam scientific objectives in geology, atmospheric science, and 3-D vision. We discuss the design of PanCam, which includes a stereo pair of Wide Angle Cameras (WACs), each of which has an 11-position filter wheel and a High Resolution Camera (HRC) for high-resolution investigations of rock texture at a distance. The cameras and electronics are housed in an optical bench that provides the mechanical interface to the rover mast and a planetary protection barrier. The electronic interface is via the PanCam Interface Unit (PIU), and power conditioning is via a DC-DC converter. PanCam also includes a calibration target mounted on the rover deck for radiometric calibration, fiducial markers for geometric calibration, and a rover inspection mirror. Key Words: Mars—ExoMars—Instrumentation—Geology—Atmosphere—Exobiology—Context. Astrobiology 17, 511–541.
AOTF near-IR spectrometers for study of Lunar and Martian surface composition
NASA Astrophysics Data System (ADS)
Korablev, O.; Kiselev, A.; Vyazovetskiy, N.; Fedorova, A.; Evdokimova, N.; Stepanov, A.; Titov, A.; Kalinnikov, Y.; Kuzmin, R. O.; Bazilevsky, A. T.; Bondarenko, A.; Moiseev, P.
2013-09-01
The series of the AOTF near-IR spectrometers is developed in Moscow Space Research Institute for study of Lunar and Martian surface composition in the vicinity of a lander or a rover. Lunar Infrared Spectrometer (LIS) is an experiment onboard Luna-Glob (launch in 2015) and Luna-Resurs (launch in 2017) Russian surface missions. The LIS is mounted on the mechanic arm of landing module in the field of view (45°) of stereo TV camera. Infrared Spectrometer for ExoMars (ISEM) is an experiment onboard ExoMars (launch in 2018) ESARoscosmos rover. The ISEM instrument is mounted on the rover's mast together with High Resolution camera (HRC). Spectrometers will provide measurements of selected surface area in the spectral range of 1.15-3.3 μm. The electrically commanded acousto-optic filter scans sequentially at a desired sampling, with random access, over the entire spectral range.
Brightness Variations in the Central Star of Eta Carinae From 1998 to the Present
NASA Technical Reports Server (NTRS)
Martin, J. C.; Koppelman, M. D.
2004-01-01
Recently, Eta Carinae has varied suprisingly in brightness combining a long term brightening trend with a 5.5-year cycle and unpredictable sporadic jumps. Only the Hubble Space Telescope had been able to provide reliable photometry of the central star resolved separately from its bright ejecta. We present data from the Hubble Space Telescope Space Telescope Imaging Spectrograph (STIS) and the Advanced Camera for Surveys High Resolution Camera (ACS/HRC) which chronicle the dramatic brightening of the central star of Eta Carinae from the 1998 "event" through 2000 and show that is has continued to slowly brighten. More frequent photometry during its recent "event" and a continued rise afterward. These data are compared to the more long term data compiled by the American Association of Variable Star Observers (AAVSO) which also shows substantial brightening between events and other intervening fluctuations in the brightness of Eta Carinae at visual wavelengths.
[Clinical processes in a high resolution clinic of specialist outpatient clinics].
Zambrana-García, J L; Torres-Jiménez, M; Rubio-Sánchez, J M; Montijano-Cabrera, A; Peña-Ojeda, J A; Velasco-Malagón, M J
The high resolution clinic (HRC) is an outpatient care process by which treatment and diagnosis are established, recorded, and completed in a single day. The aim of this study was to assess the extent to which patients with medical conditions may benefit from a single consultation system. A descriptive study of 795 first visit events, randomly selected as high-resolution consultations in cardiology, gastroenterology, internal medicine, and chest diseases. A discussion is presented on the percentage of patients who benefited from HRC and the complementary tests performed. A total of 559 (70%, 95% CI: 67-73%) of all first visits became HRCs, and 483 (61%, 95% CI: 57%-64%) required a diagnostic test that was reviewed on the same day. There were differences between medical consultations (86% in cardiology versus 44% in gastroenterology consultations, P<.001). Performing a test on the same day significantly increased the percentage of HRCs (49 versus 22%, P<.001). Ischaemic heart disease, dyspepsia, headache, and asthma were the conditions most commonly leading to HRC. The most common tests were cranial tomography, blood analysis, and ultrasound. Medical consultations may largely benefit from an HRC system, only requiring some organisational changes and no additional costs. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.
Detecting Multi-scale Structures in Chandra Images of Centaurus A
NASA Astrophysics Data System (ADS)
Karovska, M.; Fabbiano, G.; Elvis, M. S.; Evans, I. N.; Kim, D. W.; Prestwich, A. H.; Schwartz, D. A.; Murray, S. S.; Forman, W.; Jones, C.; Kraft, R. P.; Isobe, T.; Cui, W.; Schreier, E. J.
1999-12-01
Centaurus A (NGC 5128) is a giant early-type galaxy with a merger history, containing the nearest radio-bright AGN. Recent Chandra High Resolution Camera (HRC) observations of Cen A reveal X-ray multi-scale structures in this object with unprecedented detail and clarity. We show the results of an analysis of the Chandra data with smoothing and edge enhancement techniques that allow us to enhance and quantify the multi-scale structures present in the HRC images. These techniques include an adaptive smoothing algorithm (Ebeling et al 1999), and a multi-directional gradient detection algorithm (Karovska et al 1994). The Ebeling et al adaptive smoothing algorithm, which is incorporated in the CXC analysis s/w package, is a powerful tool for smoothing images containing complex structures at various spatial scales. The adaptively smoothed images of Centaurus A show simultaneously the high-angular resolution bright structures at scales as small as an arcsecond and the extended faint structures as large as several arc minutes. The large scale structures suggest complex symmetry, including a component possibly associated with the inner radio lobes (as suggested by the ROSAT HRI data, Dobereiner et al 1996), and a separate component with an orthogonal symmetry that may be associated with the galaxy as a whole. The dust lane and the x-ray ridges are very clearly visible. The adaptively smoothed images and the edge-enhanced images also suggest several filamentary features including a large filament-like structure extending as far as about 5 arcminutes to North-West.
Early Observations with the ACS Ramp Filters
NASA Astrophysics Data System (ADS)
Tsvetanov, Z.; Hartig, G.; Bohlin, R.; Tran, H. D.; Martel, A.; Sirianni, M.; Clampin, M.
2002-05-01
The Advanced Camera for Surveys (ACS) on-board the Hubble Space Telescope (HST) is equipped with a set of ramp filters which provide imaging capability at 2% and 9% bandwidth in the range 3700-10700 Å. Each ramp filter consist of three segments where the middle segment can be used with both the Wide Field Channel (WFC) and High Resolution Channel (HRC), while the inner and outer segments can be used only with WFC. The monochromatic field of view is approximately 40'' by 80''. We will present observations of the planetary nebula (PN) NGC6543 (the Cat's Eye) taken with the ACS ramp filetrs in several key emission lines - [O II] 3727, [O III] 5007, H-alpha+[N II], and [S II] 6725. These four emission lines fall onto three separate middle ramp segments - FR388N, FR505N, and FR656N - and will allow inter-comparison between the ACS ramp filters and fixed bandpass narrow-band filters F502N and F658N for both the WFC and HRC detectors. These observations were taken as part of the HST Servicing Mission Orbital Verification program and were designed to test ramp filters performance. We will demostrate our ability to obtain monochromatic (i.e., emission line) images at arbitrary wavelength and recover the surface brightness distribution. This work was supported by a NASA contract and a NASA grant.
High-resolution circuit for the diagnosis of faecal incontinence. Patient satisfaction.
Muñoz-Duyos, Arantxa; Lagares-Tena, Laura; Vargas-Pierolas, Harold; Rodón, Anna; Navarro-Luna, Albert
2017-05-01
Despite its high prevalence, faecal incontinence (FI) is still underrated and underdiagnosed. Moreover, diagnosis and subsequent treatment can be a challenge for the colorectal surgeon because of its associated social taboo and embarrassment, and the wide range of symptoms. The aim of the present study is to describe a new high-resolution circuit (HRC) for FI diagnosis, that was implemented at our center and to evaluate patient satisfaction. The structure and organization of the HRC are described. Demographic and clinical data of the patients included in the HRC between February 2014 and June 2016 were collected. Moreover, patients' satisfaction was measured through a structured survey. A total of 321 patients were evaluated in our pelvic floor outpatients clinic during the study period: 65% (210) of them had FI (81% women, median age 66 years). The mean time since FI onset was 24 (range 4-540) months. A total of 79% (165) of the patients were included in the HRC. 62% of them responded to the survey. Of these, only 32% (33) had consulted for FI before coming to our centre. The majority, 88% (90) considered that performing the 2diagnostic tests the same day of the visit was a very good option. And 94% (96) were satisfied with the information received on their FI, with a median satisfaction value of 10 (5-10). With the HRC, the patient spends about 2h in the outpatient clinic of the hospital, but leaves with the complete diagnostic process performed. The satisfaction survey confirms that most patients prefer this system. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Junfeng; Fabbiano, G.; Karovska, M.; Elvis, M.; Risaliti, G.; Zezas, A.; Mundell, C. G.
2009-10-01
We report high resolution imaging of the nucleus of the Seyfert 1 galaxy NGC 4151 obtained with a 50 ks Chandra High Resolution Camera (HRC) observation. The HRC image resolves the emission on spatial scales of 0farcs5, ~30 pc, showing an extended X-ray morphology overall consistent with the narrow-line region (NLR) seen in optical line emission. Removal of the bright point-like nuclear source and image deconvolution techniques both reveal X-ray enhancements that closely match the substructures seen in the Hubble Space Telescope [O III] image and prominent knots in the radio jet. We find that most of the NLR clouds in NGC 4151 have [O III]/soft X-ray ratio ~10, despite the distance of the clouds from the nucleus. This ratio is consistent with the values observed in NLRs of some Seyfert 2 galaxies, which indicates a uniform ionization parameter even at large radii and a density decreasing as r -2 as expected for a nuclear wind scenario. The [O III]/X-ray ratios at the location of radio knots show an excess of X-ray emission, suggesting shock heating in addition to photoionization. We examine various mechanisms for the X-ray emission and find that, in contrast to jet-related X-ray emission in more powerful active galactic nucleus, the observed jet parameters in NGC 4151 are inconsistent with synchrotron emission, synchrotron self-Compton, inverse Compton of cosmic microwave background photons or galaxy optical light. Instead, our results favor thermal emission from the interaction between radio outflow and NLR gas clouds as the origin for the X-ray emission associated with the jet. This supports previous claims that frequent jet-interstellar medium interaction may explain why jets in Seyfert galaxies appear small, slow, and thermally dominated, distinct from those kpc-scale jets in the radio galaxies.
Field Test of the ExoMars Panoramic Camera in the High Arctic - First Results and Lessons Learned
NASA Astrophysics Data System (ADS)
Schmitz, N.; Barnes, D.; Coates, A.; Griffiths, A.; Hauber, E.; Jaumann, R.; Michaelis, H.; Mosebach, H.; Paar, G.; Reissaus, P.; Trauthan, F.
2009-04-01
The ExoMars mission as the first element of the ESA Aurora program is scheduled to be launched to Mars in 2016. Part of the Pasteur Exobiology Payload onboard the ExoMars rover is a Panoramic Camera System (‘PanCam') being designed to obtain high-resolution color and wide-angle multi-spectral stereoscopic panoramic images from the mast of the ExoMars rover. The PanCam instrument consists of two wide-angle cameras (WACs), which will provide multispectral stereo images with 34° field-of-view (FOV) and a High-Resolution RGB Channel (HRC) to provide close-up images with 5° field-of-view. For field testing of the PanCam breadboard in a representative environment the ExoMars PanCam team joined the 6th Arctic Mars Analogue Svalbard Expedition (AMASE) 2008. The expedition took place from 4-17 August 2008 in the Svalbard archipelago, Norway, which is considered to be an excellent site, analogue to ancient Mars. 31 scientists and engineers involved in Mars Exploration (among them the ExoMars WISDOM, MIMA and Raman-LIBS team as well as several NASA MSL teams) combined their knowledge, instruments and techniques to study the geology, geophysics, biosignatures, and life forms that can be found in volcanic complexes, warm springs, subsurface ice, and sedimentary deposits. This work has been carried out by using instruments, a rover (NASA's CliffBot), and techniques that will/may be used in future planetary missions, thereby providing the capability to simulate a full mission environment in a Mars analogue terrain. Besides demonstrating PanCam's general functionality in a field environment, test and verification of the interpretability of PanCam data for in-situ geological context determination and scientific target selection was a main objective. To process the collected data, a first version of the preliminary PanCam 3D reconstruction processing & visualization chain was used. Other objectives included to test and refine the operational scenario (based on ExoMars Rover Reference Surface Mission), to investigate data commonalities and data fusion potential w.r.t. other instruments, and to collect representative image data to evaluate various influences, such as viewing distance, surface structure, and availability of structures at "infinity" (e.g. resolution, focus quality and associated accuracy of the 3D reconstruction). Airborne images with the HRSC-AX camera (airborne camera with heritage from the Mars Express High Resolution Stereo Camera HRSC), collected during a flight campaign over Svalbard in June 2008, provided large-scale geological context information for all field sites.
Infrared Spectrometer for ExoMars: A Mast-Mounted Instrument for the Rover
NASA Astrophysics Data System (ADS)
Korablev, Oleg I.; Dobrolensky, Yurii; Evdokimova, Nadezhda; Fedorova, Anna A.; Kuzmin, Ruslan O.; Mantsevich, Sergei N.; Cloutis, Edward A.; Carter, John; Poulet, Francois; Flahaut, Jessica; Griffiths, Andrew; Gunn, Matthew; Schmitz, Nicole; Martín-Torres, Javier; Zorzano, Maria-Paz; Rodionov, Daniil S.; Vago, Jorge L.; Stepanov, Alexander V.; Titov, Andrei Yu.; Vyazovetsky, Nikita A.; Trokhimovskiy, Alexander Yu.; Sapgir, Alexander G.; Kalinnikov, Yurii K.; Ivanov, Yurii S.; Shapkin, Alexei A.; Ivanov, Andrei Yu.
2017-07-01
ISEM (Infrared Spectrometer for ExoMars) is a pencil-beam infrared spectrometer that will measure reflected solar radiation in the near infrared range for context assessment of the surface mineralogy in the vicinity of the ExoMars rover. The instrument will be accommodated on the mast of the rover and will be operated together with the panoramic camera (PanCam), high-resolution camera (HRC). ISEM will study the mineralogical and petrographic composition of the martian surface in the vicinity of the rover, and in combination with the other remote sensing instruments, it will aid in the selection of potential targets for close-up investigations and drilling sites. Of particular scientific interest are water-bearing minerals, such as phyllosilicates, sulfates, carbonates, and minerals indicative of astrobiological potential, such as borates, nitrates, and ammonium-bearing minerals. The instrument has an ˜1° field of view and covers the spectral range between 1.15 and 3.30 μm with a spectral resolution varying from 3.3 nm at 1.15 μm to 28 nm at 3.30 μm. The ISEM optical head is mounted on the mast, and its electronics box is located inside the rover's body. The spectrometer uses an acousto-optic tunable filter and a Peltier-cooled InAs detector. The mass of ISEM is 1.74 kg, including the electronics and harness. The science objectives of the experiment, the instrument design, and operational scenarios are described.
OPERATION OF A PUBLIC GEOLOGIC CORE AND SAMPLE REPOSITORY IN HOUSTION, TEXAS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott W. Tinker; Beverly Blakeney DeJarnett
2006-04-14
The Bureau of Economic Geology's Houston Research Center (HRC) is well established as a premier regional research center for geologic research serving not only Houston, but geoscientists from around Texas, the US, and even the world. As reported in the 2004-2005 technical progress report to the DOE, the HRC provides a state-of-the-art core viewing facility, two fully equipped conference rooms, and a comprehensive technical library, all available for public use. In addition, the HRC currently now houses over 600,000 boxes of rock material, and has space to hold approximately 300,000 more boxes. Use of the facility has remained strong during this fourth year of operation; the number of patrons averaged nearly 150 per month from June 1, to 2005 May 31, 2006. This usage is a combination of individuals describing core, groups of geoscientists holding seminars and workshops, and various industry and government-funded groups holding short courses, workshops, and seminars. These numbers are in addition to the numerous daily requests from patrons desiring to have rock material shipped offsite to their own offices. The BEG/HRC secured several substantial donations of rock materials and cash totaling approximatelymore » $2.2 million during the 2005-2006 operating period. All of these funds went directly into an endowment that will, when complete, endow the HRC in perpetuity. Specific details regarding the funds in the endowment are addressed in a table later in this report. Outreach during 2005 and 2006 included many technical presentations and several publications on the HRC. Several field trips to the facility were held for geoscience professionals and grade school students alike. Goals for the upcoming year include securing donations of rock material and cash to approach full funding of the HRC endowment. Thanks to donations totaling $2.2 million from Shea Homes (heritage Unocal rock material), Chevron and others this operating year, the HRC endowment now totals $8,015,621. A major project underway for the HRC in FY2007 is improvement of the existing online core/log database into a Geoinformatics-compatible, GIS-driven online system. Usage of the HRC has gone up every year and is now very respectable. This year we will strive to raise awareness of the HRC's 100,000-volume geoscience technical library. Our original business model targeted $10 million in endowment; after several years of operation we realize we require an $11 million endowment. We are ''on plan'' and need only $$3 million to fully fund the endowment. To meet these goals in the 2006-2007 operating year will require DOE support for the fifth and final year. DOE support will allow for {approx}$$600k in endowment growth and save using the fund for operation; lack of support will result in a net negative spread of up to $1 million, and set the plan way back. We recognize that DOE budgets for oil and gas research, against best efforts, have been cut substantially this year. Any support available for HRC operation, during continuing resolution or otherwise, would have a very positive impact on this critical final year of the original business plan.« less
Operation of a Public Geologic Core and Sample Repository in Houstion, Texas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott Tinker; Beverly DeJarnett
2007-07-31
The Bureau of Economic Geology's Houston Research Center (HRC) is well established as a premier regional research center for geologic research serving not only Houston, but geoscientists from around Texas, the U. S., and even the world. As reported in the FY05 and FY06 technical progress reports to the DOE, the HRC provides a state-of-the-art core viewing facility, two fully equipped conference rooms, and a comprehensive technical library, all available for public use. In addition, the HRC currently now houses over 725,000 boxes of rock material (as of January 2008), and has space to hold approximately 300,000 more boxes. Use of the facility has remained strong; the number of patrons averaged over 100 per month from June 1, 2006 to October 2007, and 90,000 boxes of core were donated to, and received by, the HRC during this time. Usage is a combination of individuals describing core, groups of geoscientists holding seminars and workshops, and various industry and government-funded groups holding short courses, workshops, and seminars. These numbers are in addition to the numerous daily requests from patrons desiring to have rock material shipped offsite to their own offices. The BEG/HRC secured several substantial donations of rock materials and cash totaling approximatelymore » $2.2 million during the 2005-2006 operating period. All of these funds went directly into an endowment that UT is building in order to operate the HRC primarily off a portion of the interest generated by the fund. Specific details regarding the funds in the endowment are addressed in a table later in this report. Outreach during 2005 and 2006 included many technical presentations and several publications on the HRC. Several field trips to the facility were held for geoscience professionals and grade school students alike. Goals for the upcoming year involve securing a major donation of rock material and cash in order to approach full funding of the HRC endowment. Thanks to donations totaling $2.2 million from Shea Homes (heritage Unocal rock material),Chevron and others this operating year, the HRC endowment now totals $8,015,621. A major project underway for the HRC in FY2007 is improvement of the existing online core/log database into a geoinformatics-compatible, GIS-driven online system. Usage of the HRC has gone up every year and is now very respectable. This year we will strive to raise awareness of the HRC's 100,000-volume geoscience technical library. Our original business model targeted $10 million in endowment; after several years of operation we realize we require an $11 million endowment. We are 'on plan' and need only $$3 million to fully fund the endowment. To meet these goals in the 2007 operating year will require DOE support for the fifth and final year. DOW support will allow for {approx}$$600K in endowment growth and save using the fund for operation; lack of support will result in a net negative spread of up to $1 million, and set the plan way back. We recognize that DOE budgets for oil and gas research, against best efforts, have been cut substantially this year. Any support available for HRC operation, during continuing resolution or otherwise, would have a very positive impact on this critical final year of the original business plan.« less
AOTF near-IR spectrometers for study of Lunar and Martian surface composition
NASA Astrophysics Data System (ADS)
Ivanov, A.; Korablev, O.; Mantsevich, S.; Vyazovetskiy, N.; Fedorova, A.; Evdokimova, N.; Stepanov, A.; Titov, A.; Kalinnikov, Y.; Kuzmin, R.; Kiselev, A.; Bazilevsky, A.; Bondarenko, A.; Dokuchaev, I.; Moiseev, P.; Victorov, A.; Berezhnoy, A.; Skorov, Y.; Bisikalo, D.; Velikodsky, Y.
2014-04-01
The series of the AOTF near-IR spectrometers is developed in Moscow Space Research Institute for study of Lunar and Martian surface composition in the vicinity of a lander or a rover. Lunar Infrared Spectrometer (LIS) is an experiment onboard Luna-Glob (launch in 2017) and Luna- Resurs (launch in 2019) Russian surface missions. It's a pencil-beam spectrometer to be pointed by a robotic arm of the landing module. The instrument's field of view (FOV) of 1° is co-aligned with the FOV(45°) of a stereo TV camera. Infrared Spectrometer for ExoMars (ISEM) is an experiment onboard ExoMars (launch in 2018) ESARoscosmos rover. It's spectrometer based on LIS with required redesign for ExoMars mission. The ISEM instrument is mounted on the rover's mast coaligned with the FOV (5°) of High Resolution camera (HRC). Spectrometers and are intended for study of the surface composition in the vicinity of the lander and rover. The spectrometers will provide measurements of selected surface areas in the spectral range of 1.15-3.3 μm. The spectral selection is provided by acoustooptic tunable filter (AOTF), which scans the spectral range sequentially. Electrical command of the AOTF allows selecting the spectral sampling, and permits a random access if needed.
Infrared Spectrometer for ExoMars: A Mast-Mounted Instrument for the Rover.
Korablev, Oleg I; Dobrolensky, Yurii; Evdokimova, Nadezhda; Fedorova, Anna A; Kuzmin, Ruslan O; Mantsevich, Sergei N; Cloutis, Edward A; Carter, John; Poulet, Francois; Flahaut, Jessica; Griffiths, Andrew; Gunn, Matthew; Schmitz, Nicole; Martín-Torres, Javier; Zorzano, Maria-Paz; Rodionov, Daniil S; Vago, Jorge L; Stepanov, Alexander V; Titov, Andrei Yu; Vyazovetsky, Nikita A; Trokhimovskiy, Alexander Yu; Sapgir, Alexander G; Kalinnikov, Yurii K; Ivanov, Yurii S; Shapkin, Alexei A; Ivanov, Andrei Yu
ISEM (Infrared Spectrometer for ExoMars) is a pencil-beam infrared spectrometer that will measure reflected solar radiation in the near infrared range for context assessment of the surface mineralogy in the vicinity of the ExoMars rover. The instrument will be accommodated on the mast of the rover and will be operated together with the panoramic camera (PanCam), high-resolution camera (HRC). ISEM will study the mineralogical and petrographic composition of the martian surface in the vicinity of the rover, and in combination with the other remote sensing instruments, it will aid in the selection of potential targets for close-up investigations and drilling sites. Of particular scientific interest are water-bearing minerals, such as phyllosilicates, sulfates, carbonates, and minerals indicative of astrobiological potential, such as borates, nitrates, and ammonium-bearing minerals. The instrument has an ∼1° field of view and covers the spectral range between 1.15 and 3.30 μm with a spectral resolution varying from 3.3 nm at 1.15 μm to 28 nm at 3.30 μm. The ISEM optical head is mounted on the mast, and its electronics box is located inside the rover's body. The spectrometer uses an acousto-optic tunable filter and a Peltier-cooled InAs detector. The mass of ISEM is 1.74 kg, including the electronics and harness. The science objectives of the experiment, the instrument design, and operational scenarios are described. Key Words: ExoMars-ISEM-Mars-Surface-Mineralogy-Spectroscopy-AOTF-Infrared. Astrobiology 17, 542-564.
Low- to Middle-Latitude X-Ray Emission from Jupiter
NASA Technical Reports Server (NTRS)
Bhardwaj, Anil; Elsner, Ronald F.; Gladstone, G. Randall; Waite, J. Hunter, Jr.; Branduardi-Raymont, Graziella; Cravens, Thomas E.; Ford, Peter G.
2006-01-01
The Chandra X-ray Observatory (CXO) observed Jupiter during the period 24-26 February 2003 for approx. 40 hours (4 Jupiter rotations), using both the spectroscopy array of the Advanced CCD Imaging Spectrometer (ACIS-S) and the imaging array of the High-Resolution Camera (HRC-I). Two ACIS-S exposures, each -8.5 hours long, were separated by an HRC-I exposure of approx. 20 hours. The low- to middle-latitude nonauroral disk X-ray emission is much more spatially uniform than the auroral emission. However, the low- to middle-latitude X-ray count rate shows a small but statistically significant hour angle dependence and depends on surface magnetic field strength. In addition, the X-ray spectra from regions corresponding to 3-5 gauss and 5-7 gauss surface fields show significant differences in the energy band 1.26-1.38 keV, perhaps partly due to line emission occurring in the 3-5 gauss region but not the 5-7 gauss region. A similar correlation of surface magnetic field strength with count rate is found for the 18 December 2000 HRC-I data, at a time when solar activity was high. The low- to middle-latitude disk X-ray count rate observed by the HRC-I in the February 2003 observation is about 50% of that observed in December 2000, roughly consistent with a decrease in the solar activity index (F10.7 cm flux) by a similar amount over the same time period. The low- to middle-latitude X-ray emission does not show any oscillations similar to the approx. 45 min oscillations sometimes seen from the northern auroral zone. The temporal variation in Jupiter's nonauroral X-ray emission exhibits similarities to variations in solar X-ray flux observed by GOES and TIMED/SEE. The two ACIS-S 0.3-2.0 keV low- to middle-latitude X-ray spectra are harder than the auroral spectrum and are different from each other at energies above 0.7 keV, showing variability in Jupiter's nonauroral X-ray emission on a timescale of a day. The 0.3-2.0 keV X-ray power emitted at low to middle latitudes is 0.21 GW and 0.39 GW for the first and second ACIS-S exposures, respectively. We suggest that X-ray emission from Jupiter's disk may be largely generated by the scattering and fluorescence of solar X rays in its upper atmosphere, especially at times of high incident solar X-ray flux. However, the dependence of count rate on surface magnetic-field strength may indicate the presence of some secondary component, possibly ion precipitation from radiation belts close to the planet.
Low- to Mid-Latitude X-Ray Emission from Jupiter
NASA Technical Reports Server (NTRS)
Bhardwaj, Anil; Elsner, Ronald F.; Gladstone, G. Randall; Waite, J. Hunter, Jr.; Branduardi-Raymont, Graziella; Cravens, Thomas E.; Ford, Peter
2006-01-01
The Chandra X-ray Observatory (CXO) observed Jupiter during the period 2003 February 24-26 for approx.40 hours (4 Jupiter rotations), using both the spectroscopy array of the Advanced CCD Imaging Spectrometer (ACIS-S) and the imaging array of the High-Resolution Camera (HRC-I). Two ACIS-S exposures, each approx.8.5 hr long, were separated by an HRC-I exposure of approx.20 hr. The low- to mid-latitude non-auroral disk X-ray emission is much more spatially uniform than the auroral emission. However, the low- to mid-latitude X-ray count rate shows a small but statistically significant hour angle dependence, and is higher in regions of relatively low surface magnetic field strength, confirming ROSAT results. In addition, the spectrum from the low surface field region shows an enhancement in the energy band 1.14- 1.38 keV, perhaps partly due to line emission from that region. Correlation of surface magnetic field strength with count rate is not found for the 2000 December HRC-I data, at a time when solar activity was high. The low- to mid-latitude disk X-ray count rate observed by the HRC-I in the 2003 February observation is about 50% of that observed in 2000 December, roughly consistent with a decrease in the solar activity index (F10.7 cm flux) by a similar amount over the same time period. The low- to mid-latitude X-ray emission does not show any oscillations similar to the -45 minute oscillations sometimes seen from the northern auroral zone. The temporal variation in Jupiter's non-auroral X-ray emission exhibits similarities to variations in solar X-ray flux observed by GOES and TIMED/SEE. The two ACIS-S 0.3-2 keV low- to mid-latitude X-ray spectra are harder than the auroral spectrum, and are different from each other at energies above 0.7 keV, showing variability in Jupiter s non-auroral X-ray emission on a time scale of a day. The 0.3-2.0 keV X-ray power emitted at low- to mid-latitudes is 0.21 GW and 0.39 GW for the first and second ACIS-S exposures, respectively. We suggest that X-ray emission from Jupiter's disk may be largely generated by solar X-rays resonantly and fluorescently scattered in its upper atmosphere, especially at times of high incident solar X-ray flux. However, the correlation of higher count rate with low surface magnetic-field strength indicates the presence of some secondary component, possibly ion precipitation from radiation belts closer to the planet than elsewhere at low- to mid-latitudes.
White, Christina A; Jones, Marshall R; Kuester, Melanie K; Myers, Kelly L; Schnarr, Barbara A
2015-05-01
To establish a cost-effective centralized pharmacy call center to serve the patients of Veterans Integrated Service Network (VISN) 11 that would meet established performance metrics. A pilot project began in August 2011 with the Indianapolis VA Medical Center (VAMC) and the Health Resource Center (HRC) in Topeka, Kansas. The Indianapolis VAMC used a first-call resolution business model consisting of pharmacy technicians receiving tier 1 phone calls that could be escalated to a tier 2 line that consisted of lead technicians and pharmacists, while the HRC utilized general telephone agents that would transfer unresolved calls to the primary facility. Pre- and post-VISN 11 Pharmacy Call Center performance metrics were compared for each of the 7 facilities in the network with the goals being monthly average abandoned call rate less than 5% and average speed to answer less than 30 seconds. Cost per call was also compared. The average abandoned call rate for the network during the year prior to VISN 11 Pharmacy Call Center implementation (August 2010-July 2011) was 15.66% and decreased to 3% in July 2014. The average abandoned call rate decreased for each individual facility. In fiscal year 2014, the VISN 11 Pharmacy Call Center was operating at a cost of $4.35 per call while providing more services than the HRC, resulting in less workload being transferred back to the individual facilities. A centralized VISN pharmacy call center is a reasonable alternative to individual facility call centers or the HRC.
Jones, Marshall R.; Kuester, Melanie K.; Myers, Kelly L.; Schnarr, Barbara A.
2015-01-01
Purpose: To establish a cost-effective centralized pharmacy call center to serve the patients of Veterans Integrated Service Network (VISN) 11 that would meet established performance metrics. Methods: A pilot project began in August 2011 with the Indianapolis VA Medical Center (VAMC) and the Health Resource Center (HRC) in Topeka, Kansas. The Indianapolis VAMC used a first-call resolution business model consisting of pharmacy technicians receiving tier 1 phone calls that could be escalated to a tier 2 line that consisted of lead technicians and pharmacists, while the HRC utilized general telephone agents that would transfer unresolved calls to the primary facility. Pre- and post-VISN 11 Pharmacy Call Center performance metrics were compared for each of the 7 facilities in the network with the goals being monthly average abandoned call rate less than 5% and average speed to answer less than 30 seconds. Cost per call was also compared. Results: The average abandoned call rate for the network during the year prior to VISN 11 Pharmacy Call Center implementation (August 2010-July 2011) was 15.66% and decreased to 3% in July 2014. The average abandoned call rate decreased for each individual facility. In fiscal year 2014, the VISN 11 Pharmacy Call Center was operating at a cost of $4.35 per call while providing more services than the HRC, resulting in less workload being transferred back to the individual facilities. Conclusion: A centralized VISN pharmacy call center is a reasonable alternative to individual facility call centers or the HRC. PMID:26405322
The Highest Resolution X-ray View of the Nuclear Region of NGC 4151
NASA Astrophysics Data System (ADS)
Wang, Junfeng; Fabbiano, G.; Karovska, M.; Elvis, M.; Risaliti, G.; Zezas, A.; Mundell, C. G.
2009-09-01
We report high resolution imaging of the nucleus of the Seyfert 1 galaxy NGC 4151 obtained with a 50 ks Chandra HRC observation. The HRC image resolves the emission on spatial scales of 0.5 arcsec (30 pc), showing an extended X-ray morphology overall consistent with the narrow line region seen in optical line emission. Removal of the bright point-like nuclear source and image deconvolution technique both reveal X-ray enhancements that closely match the substructures seen in the HST [OIII] image and prominent knots in the radio jet. We find that most of the NLR clouds in NGC 4151 have [OIII] to soft X-ray ratio consistent with the values observed in NLRs of some Seyfert 2 galaxies, which indicates a uniform ionization parameter even at large radii and a density dependence ∝ r^{-2} as expected in the disk wind scenario. We examine various X-ray emission mechanisms of the radio jet and consider thermal emission from interaction between radio outflow and the NLR clouds the most probable origin for the X-ray emission associated with the jet.
Pollak, Adam J.; Haghighi, Kobra; Kunduri, Swati; Arvanitis, Demetrios A.; Liu, Guan-Sheng; Singh, Vivek P.; Gonzalez, David J.; Sanoudou, Despina; Wiley, Sandra E.; Dixon, Jack E.; Kranias, Evangelia G.
2017-01-01
Precise Ca cycling through the sarcoplasmic reticulum (SR), a Ca storage organelle, is critical for proper cardiac muscle function. This cycling initially involves SR release of Ca via the ryanodine receptor, which is regulated by its interacting proteins junctin and triadin. The sarco/endoplasmic reticulum Ca ATPase (SERCA) pump then refills SR Ca stores. Histidine-rich Ca-binding protein (HRC) resides in the lumen of the SR, where it contributes to the regulation of Ca cycling by protecting stressed or failing hearts. The common Ser96Ala human genetic variant of HRC strongly correlates with life-threatening ventricular arrhythmias in patients with idiopathic dilated cardiomyopathy. However, the underlying molecular pathways of this disease remain undefined. Here, we demonstrate that family with sequence similarity 20C (Fam20C), a recently characterized protein kinase in the secretory pathway, phosphorylates HRC on Ser96. HRC Ser96 phosphorylation was confirmed in cells and human hearts. Furthermore, a Ser96Asp HRC variant, which mimics constitutive phosphorylation of Ser96, diminished delayed aftercontractions in HRC null cardiac myocytes. This HRC phosphomimetic variant was also able to rescue the aftercontractions elicited by the Ser96Ala variant, demonstrating that phosphorylation of Ser96 is critical for the cardioprotective function of HRC. Phosphorylation of HRC on Ser96 regulated the interactions of HRC with both triadin and SERCA2a, suggesting a unique mechanism for regulation of SR Ca homeostasis. This demonstration of the role of Fam20C-dependent phosphorylation in heart disease will open new avenues for potential therapeutic approaches against arrhythmias. PMID:28784772
Monitoring the health of the HRC UV Ion shield
NASA Astrophysics Data System (ADS)
CXC Calibration
2003-09-01
To protect ACIS from further radiation damage, it is stowed during all radiation belt passages. During this time, the HRC is at the focal point of the mirrors with its door open. At present, the transmission of the UVIS is only monitored once per year with short Vega observations. The HRC PI team has requested, and been given approval by the Director's office, to observe Vega every 3 months for the next year to determine if the filter is being damaged by radiation. This proposal contains 8 additional HRC observations of Vega for AO5. Four observations (one for each HRC plate) will take place in August 2004 and the remaining 4 in November 2004.
VizieR Online Data Catalog: Astrometric monitoring of ultracool dwarf binaries (Dupuy+, 2017)
NASA Astrophysics Data System (ADS)
Dupuy, T. J.; Liu, M. C.
2017-09-01
In Table 1 we list all 33 binaries in our Keck+CFHT astrometric monitoring sample, along with three other binaries that have published orbit and parallax measurements. We began obtaining resolved Keck AO astrometry in 2007-2008, and we combined our new astrometry with available data in the literature or public archives (e.g., HST and Gemini) to refine our orbital period estimates and thereby our prioritization for Keck observations. We present here new Keck/NIRC2 AO imaging and non-redundant aperture-masking observations, in addition to a re-analysis of our own previously published data and publicly available archival data for our sample binaries. Table 2 gives our measured astrometry and flux ratios for all Keck AO data used in our orbital analysis spanning 2003 Apr 15 to 2016 May 13. In total there are 339 distinct measurements (unique bandpass and epoch for a given target), where 302 of these are direct imaging and 37 are non-redundant aperture masking. Eight of the imaging measurements are from six unpublished archival data sets. See section 3.1.1 for further details. In addition to our Keck AO monitoring, we also obtained data for three T dwarf binaries over a three-year HST program using the Advanced Camera for Surveys (ACS) Wide Field Camera (WFC) in the F814W bandpass. See section 3.1.2 for further details. Many of our sample binaries have HST imaging data in the public archive. We have re-analyzed the available archival data coming from the WFPC2 Planetary Camera (WFPC2-PC1), ACS High Resolution Channel (ACS-HRC), and NICMOS Camera 1 (NICMOS-NIC1). See section 3.1.3 for further details. We present here an updated analysis of our data from the Hawaii Infrared Parallax Program that uses the CFHT facility infrared camera WIRCam. Our observing strategy and custom astrometry pipeline are described in detail in Dupuy & Liu (2012, J/ApJS/201/19). See section 3.2 for further explanations. (10 data files).
ERIC Educational Resources Information Center
Pluviose, David
2007-01-01
Launched in 1985 at Arizona State University, the Hispanic Research Center's (HRC) efforts to promote Latino and Chicano art and issues have flourished in recent years. In 2004, the HRC hosted the Arizona International Latina/o Arts Festival in collaboration with the Mesa Southwest Museum. The HRC has also founded a mentoring institute for…
Prainsack, B; Cherkas, L F; Spector, T D
2007-08-01
Surveys have shown opposition to human reproductive cloning (HRC) in many countries. Views of identical (monozygotic, MZ) twins are of particular interest, as they naturally share 100% of their genes. We investigated attitudes of British twins towards HRC in the context of assisted reproduction technologies (ART) and gene selection. About 4651 identical and non-identical (dizygotic, DZ) twins expressed their degree of agreement or disagreement to nine statements relating to ART, gene selection and HRC in a self-completion questionnaire. Most subjects (70% and 78% respectively) did not regard the use of medical technologies to treat infertility as interfering with either nature or God's will, despite believing that infertility is not a disease (54%). Attitudes to gene selection and HRC were context dependent, with more favourable views towards preventing serious diseases than towards enhancing traits. About 44% supported a permanent ban of HRC. MZ twins were significantly more likely to agree that HRC should be allowed for medical purposes, such as saving a sibling's life, than were DZ twins. Increasing religiosity generally correlated with more negative attitudes. Many attitudes are context dependent. More positive views of MZ twins towards HRC could be linked to their experience with being genetically identical.
Elsner, D
2006-01-01
Human reproductive cloning (HRC) has not yet resulted in any live births. There has been widespread condemnation of the practice in both the scientific world and the public sphere, and many countries explicitly outlaw the practice. Concerns about the procedure range from uncertainties about its physical safety to questions about the psychological well‐being of clones. Yet, key aspects such as the philosophical implications of harm to future entities and a comparison with established reproductive technologies such as in vitro fertilisation (IVF) are often overlooked in discussions about HRC. Furthermore, there are people who are willing to use the technology. Several scientists have been outspoken in their intent to pursue HRC. The importance of concerns about the physical safety of children created by HRC and comparisons with concerns about the safety of IVF are discussed. A model to be used to determine when it is acceptable to use HRC and other new assisted reproductive technologies, balancing reproductive freedom and safety concerns, is proposed. Justifications underpinning potential applications of HRC are discussed, and it is determined that these are highly analogous to rationalisations used to justify IVF treatment. It is concluded that people wishing to conceive using HRC should have a prima facie negative right to do so. PMID:17012502
Elsner, D
2006-10-01
Human reproductive cloning (HRC) has not yet resulted in any live births. There has been widespread condemnation of the practice in both the scientific world and the public sphere, and many countries explicitly outlaw the practice. Concerns about the procedure range from uncertainties about its physical safety to questions about the psychological well-being of clones. Yet, key aspects such as the philosophical implications of harm to future entities and a comparison with established reproductive technologies such as in vitro fertilisation (IVF) are often overlooked in discussions about HRC. Furthermore, there are people who are willing to use the technology. Several scientists have been outspoken in their intent to pursue HRC. The importance of concerns about the physical safety of children created by HRC and comparisons with concerns about the safety of IVF are discussed. A model to be used to determine when it is acceptable to use HRC and other new assisted reproductive technologies, balancing reproductive freedom and safety concerns, is proposed. Justifications underpinning potential applications of HRC are discussed, and it is determined that these are highly analogous to rationalisations used to justify IVF treatment. It is concluded that people wishing to conceive using HRC should have a prima facie negative right to do so.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Ping; Van Nostrand, Joy D.; He, Zhili
Cr(VI) is a widespread environmental contaminant that is highly toxic and soluble. Previous work indicated that a one-time amendment of polylactate hydrogen-release compound (HRC) reduced groundwater Cr(VI) concentrations for >3.5 years at a contaminated aquifer; however, microbial communities responsible for Cr(VI) reduction are poorly understood. Here in this study, we hypothesized that HRC amendment would significantly change the composition and structure of groundwater microbial communities, and that the abundance of key functional genes involved in HRC degradation and electron acceptor reduction would increase long-term in response to this slowly degrading, complex substrate. To test these hypotheses, groundwater microbial communities weremore » monitored after HRC amendment for >1 year using a comprehensive functional gene microarray. The results showed that the overall functional composition and structure of groundwater microbial communities underwent sequential shifts after HRC amendment. Particularly, the abundance of functional genes involved in acetate oxidation, denitrification, dissimilatory nitrate reduction, metal reduction, and sulfate reduction significantly increased. The overall community dynamics was significantly correlated with changes in groundwater concentrations of microbial biomass, acetate, NO 3 -, Cr(VI), Fe(II) and SO 4 2-. Finally, our results suggest that HRC amendment primarily stimulated key functional processes associated with HRC degradation and reduction of multiple electron acceptors in the aquifer toward long-term Cr(VI) reduction.« less
SUPPLEMENTARY COMPARISON: Final report on Supplementary Comparison APMP.M.H-S1
NASA Astrophysics Data System (ADS)
Kongkavitool, Rugkanawan; Hattori, Koichiro; Sanh, Vo; Yen, Lim Gin
2007-01-01
This report presents the results of supplementary comparison APMP.M.H-S1 among four national metrology institutes (NIMT, NMIJ/AIST, VMI and SPRING). The comparison was carried out during October 2004 to January 2005 in order to determine the capability of the primary Rockwell hardness standard, including standard conditions, of each participant, to confirm the accuracy of Rockwell hardness scale C measurement declared by the participant, which includes the effect of each participant's primary indenter and determine the degrees of equivalence of hardness scale measurement in the range 20 HRC to 60 HRC. Furthermore, the comparison was carried out a by common indenter, which was provided by the pilot institute, in order to determine the measurement capability of the participant's primary machine without the influence of the indenter, as a study of scientific purpose. The pilot institute was the National Institute of Metrology (Thailand), NIMT. There were two sets of artifacts for the comparison. Each set was composed of nine hardness blocks: 20 HRC, 25 HRC, 30 HRC, 35 HRC, 40 HRC, 45 HRC, 50 HRC, 55 HRC, 60 HRC. The verification of the participant's primary Rockwell hardness machine was carried out according to ISO6508-3 before making the measurement. The pilot institute made measurements at the beginning and the end of the comparison in order to monitor the stability of the artifacts. The degree of equivalence of each national primary hardness standard was expressed quantitatively by two terms, the deviation from KCRV and the uncertainty of this deviation at a 95% level of confidence. The En parameter was calculated to express the equivalence between the measurements of participants as well. The degree of equivalence between pairs of participating institutes was expressed by the difference of their deviations from the key comparison reference value and the uncertainty of this difference at the 95% level of confidence. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
OPERATION OF A PUBLIC GEOLOGIC CORE AND SAMPLE REPOSITORY IN HOUSTON, TEXAS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott W. Tinker; Beverly Blakeney DeJarnett; Laura C. Zahm
2005-04-01
The Bureau of Economic Geology's Houston Research Center (HRC) is well established as a premier regional research center for geologic research serving not only Houston, but geoscientists from around Texas, the U. S., and even the world. As reported in the 2003-2004 technical progress report to the DOE, the HRC provides a state-of-the-art core viewing facility, two fully equipped conference rooms, and a comprehensive technical library, all available for public use. In addition, the HRC currently houses over 500,000 boxes of rock material, and has space to hold approximately 400,000 more boxes. Use of the facility has continued to increasemore » during this third year of operation; over the past twelve months the HRC has averaged approximately 200 patrons per month. This usage is a combination of individuals describing core, groups of geoscientists holding seminars and workshops, and various industry and government-funded groups holding short courses, workshops, and seminars. The BEG/HRC secured several substantial donations of rock materials and/or cash during this operating period. All of these funds went directly into the endowment. Outreach during 2004 and 2005 included many technical presentations and several publications on the HRC. Several field trips to the facility were held for geoscience professionals and grade school students alike. Goals for the upcoming year involve securing more donations of rock material and cash in order to fully fund the HRC endowment. BEG will also continue to increase the number of patrons using the facility, and we will strive to raise awareness of the HRC's 100,000-volume geoscience technical library.« less
Neuropsychological evaluation of high-risk children from birth to seven years of age.
Nogueira Cruz, Judith; Laynez Rubio, Carolina; Cruz Quintana, Francisco; Perez Garcia, Miguel
2012-03-01
High Risk Children (HRC) are those with an increased risk of abnormal development due to any factor affecting neurological growth. Those factors have been the focus of most studies in this area. However, little is known about their long-term consequences over the course of child development. The goal was to study the cognitive, emotional and academic outcomes of 7-year-old children diagnosed as HRC at birth. We compared 14 HRC and 20 healthy children using the WISC-IV, BASC and Brunet-Lezine tests. HRC showed cognitive, emotional and academic deficits compared with healthy children. However, Brunet-Lezine scores obtained over the course of development (6, 12, 18 and 24 months) were not predictive of the children's' current psychological status. Long-term follow-up with HRC should be maintained until 7 years of age, at which point an appropriate treatment should be implemented.
McNally, R Ryan; Zeng, Quan; Sundin, George W
2016-05-20
Many Gram-negative bacterial pathogens mediate host-microbe interactions via utilization of the type III secretion (T3S) system. The T3S system is a complex molecular machine consisting of more than 20 proteins. Collectively, these proteins translocate effectors across extracellular space and into the host cytoplasm. Successful translocation requires timely synthesis and allocation of both structural and secreted T3S proteins. Based on amino acid conservation in animal pathogenic bacteria, HrcU and HrpP were examined for their roles in regulation of T3S hierarchy. Both HrcU and HrpP were shown to be required for disease development in an immature pear infection model and respective mutants were unable to induce a hypersensitive response in tobacco. Using in vitro western blot analyses, both proteins were also shown to be required for the secretion of DspA/E, a type 3 effector and an important pathogenicity factor. Via yeast-two hybridization (Y2H), HrpP and HrcU were revealed to exhibit protein-protein binding. Finally, all HrcU and HrpP phenotypes identified were shown to be dependent on a conserved amino acid motif in the cytoplasmic tail of HrcU. Collectively, these data demonstrate roles for HrcU and HrpP in regulating T3S and represent the first attempt in understanding T3S heirarchy in E. amylovora.
Ramos-Campo, Domingo J; Martínez-Guardado, Ismael; Olcina, Guillermo; Marín-Pagán, Cristian; Martínez-Noguera, Francisco J; Carlos-Vivas, Jorge; Alcaraz, Pedro E; Rubio-Arias, Jacobo A
2018-05-23
Recent acute studies have shown that high-intensity resistance circuit-based (HRC) training in hypoxia increases metabolic stress. However, no intervention studies have yet proven their effectiveness. This study aimed to analyse the effect of 8 weeks of HRC in hypoxia on aerobic performance, resting energy expenditure (REE), repeat sprint ability (RSA) and haematological variables. Twenty-eight subjects were assigned to hypoxia (FiO 2 =15%; HRC hyp : n=15; age: 24.6±6.8 years; height: 177.4±5.9 cm; weight: 74.9±11.5 kg) and normoxia (FiO 2 = 20.9%; HRC norm : n=13; age: 23.2±5.2 years; height: 173.4±6.2 cm; weight: 69.4±7.4 kg) groups. Each training session consisted of two blocks of three exercises (Block 1: bench press, leg extension, front pull down; 2: deadlift, elbow flexion, ankle extension). Each exercise was performed at 6 repetitions maximum. Participants exercised twice weekly for 8 weeks and before and after the training programme blood test, REE, RSA and treadmill running test were performed. Fatigue index in the RSA test was significantly decreased in the HRC hyp (-0.9%; p<0.01; ES=2.75) but not in the HRC norm . No changes were observed in REE and haematological variables. Absolute (4.5%; p=0.014; ES=0.42) and relative (5.2%; p=0.008; ES=0.43) maximal oxygen uptake (VO 2 max), speed at VO 2 max (4%; p=0.010; ES=0.25) and time to exhaustion (4.1%; p=0.012; ES=0.26) were significantly increased in HRC hyp but not in the HRC norm . No significant differences between groups were found. Compared with normoxic conditions, 8 weeks of HRC training under hypoxic conditions efficiently improves aerobic performance and RSA without changes in REE and red blood O 2 -carrying capacity. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Role of histidine-related compounds to intracellular buffering in fish skeletal muscle.
Abe, H; Dobson, G P; Hoeger, U; Parkhouse, W S
1985-10-01
Histidine-related compounds (HRC) were analyzed in fish skeletal muscle as a means of identifying their precise role in intracellular buffering. Fish muscle was used because it contains two functionally and spatially distinct fiber types, red and white. Two fish species, rainbow trout (Salmo gairdneri) and the Pacific blue marlin (Makaira nigricans), were studied because these species demonstrate widely different activity patterns. Marlin red and white muscle buffer capacity was two times higher than trout with white muscle, buffering being two times greater than red in both species. Buffer capacity was highest in the 6.5-7.5 pH range for all tissues, which corresponded to their high anserine levels. The titrated HRC buffering was greater than the observed HRC buffering, which suggested that not all HRC were available to absorb protons. The HRC contribution to total cellular buffering varied from a high of 62% for marlin white to a low of 7% for trout red. The other principal buffers were found to be phosphate and protein with taurine contributing within red muscle in the 7.0-8.0 pH range. HRC were found to be dominant in skeletal muscle buffering by principally accounting for the buffering capacity differences found between the species and fiber types.
2013-01-01
Background To cope with environmental challenges bacteria possess sophisticated defense mechanisms that involve stress-induced adaptive responses. The canonical stress regulators CtsR and HrcA play a central role in the adaptations to a plethora of stresses in a variety of organisms. Here, we determined the CtsR and HrcA regulons of the lactic acid bacterium Lactobacillus plantarum WCFS1 grown under reference (28°C) and elevated (40°C) temperatures, using ctsR, hrcA, and ctsR-hrcA deletion mutants. Results While the maximum specific growth rates of the mutants and the parental strain were similar at both temperatures (0.33 ± 0.02 h-1 and 0.34 ± 0.03 h-1, respectively), DNA microarray analyses revealed that the CtsR or HrcA deficient strains displayed altered transcription patterns of genes encoding functions involved in transport and binding of sugars and other compounds, primary metabolism, transcription regulation, capsular polysaccharide biosynthesis, as well as fatty acid metabolism. These transcriptional signatures enabled the refinement of the gene repertoire that is directly or indirectly controlled by CtsR and HrcA of L. plantarum. Deletion of both regulators, elicited transcriptional changes of a large variety of additional genes in a temperature-dependent manner, including genes encoding functions involved in cell-envelope remodeling. Moreover, phenotypic assays revealed that both transcription regulators contribute to regulation of resistance to hydrogen peroxide stress. The integration of these results allowed the reconstruction of CtsR and HrcA regulatory networks in L. plantarum, highlighting the significant intertwinement of class I and III stress regulons. Conclusions Taken together, our results enabled the refinement of the CtsR and HrcA regulatory networks in L. plantarum, illustrating the complex nature of adaptive stress responses in this bacterium. PMID:24238744
The High Resolution Chandra X-Ray Spectrum of 3C273
NASA Technical Reports Server (NTRS)
Fruscione, Antonella; Lavoie, Anthony (Technical Monitor)
2000-01-01
The bright quasar 3C273 was observed by Chandra in January 2000 for 120 ksec as a calibration target. It was observed with all detector- plus-grating combinations (ACIS+HETG, ACIS+LETG, and HRC+LETG) yielding an X-ray spectrum across the entire 0.1-10 keV band with unprecedented spectral resolution. At about 10 arcsec from the nucleus, an X-ray jet is also clearly visible and resolved in the Oth order images. While the jet is much fainter than the nuclear source, the Chandra spatial resolution allows, for the first time, spectral analysis of both components separately. We will present detailed spectral analysis with particular emphasis on possible absorption features and comparison with simultaneous BeppoSAX data.
A High-Resolution Cluster of Oceanographic Instruments for Boundary Layer Measurements under Ice.
1985-11-01
arrangement for use with laser velocimetry. The EO components are mounted on an aluminum chassis, which is in turn placed in an underwater housing made...temperature/conductivity probe pair used * on the HRC cluster. It consists of a thermistor probe (FASTIP, Model FP07, Thermometrics , Inc.) and a dual...component. The orientation of all three DLT)V pairs is shown in Figure 1. 3.2 Temperature and Conductivity Probes The FASTIP thermistor by Thermometrics
Preliminary Results from Recent Simultaneous Chandra/HST Observations of Jupiter Auroral Zones
NASA Technical Reports Server (NTRS)
Elsner, R.; Gladstone, R.; Waite, H.; Majeed, T.; Ford, P.; Grodent, D.; Bwardwaj, A.; Howell, R.; Cravens, T.; MacDowell, R.
2003-01-01
Jupiter was observed by the Chandra X-ray Observatory in late February, 2003, for 144 ks, using both the ACIS-S and HRC-I imaging x-ray cameras. Five orbits of HST STIS observations of the planet's northern auroral zone were obtained during the ACIS-S observations. These data are providing a wealth of information about Jupiter's auroral activity, including the first x-ray spectra from the x-ray hot spots inside the auroral ovals. We will also discuss the approximately 45 minute quasi-periodicity in the auroral x-ray emission - which correlates well with simultaneous observations of radio bursts by the Ulysses spacecraft - and a possible phase relation between the emission from the northern and southern x-ray aurora.
Jiang, Ying-Ping; Liu, Hao; Xu, Ping; Wang, Yan; Lu, Guang-Hua
2011-04-01
To study the changes of cognitive attention-related brain function in the heroin addicts before and after electro-acupuncture (EA) intervention for exploring the concerned neuro-mechanism of addictive relapse and the central action role of EA intervention. Adopting event-related potential (ERP) technique, the ERP at 64 electrode spots in 10 heroin addicts (test group) were recorded before and after EA intervention with dot-probe experimental form during implementing cognitive task on positive emotional clue (PEC), negative emotional clues (NEC), and heroin-related clue (HRC). The P200 amplitude components on the selected observation points (Fz, Cz, and Pz) were analyzed and compared with those obtained from 10 healthy subjects as the control. Before EA, the ERP of attention on HRC in the test group was higher than that on PEC and NEC (P<0.05) and significantly higher than that in the control group (P<0.05); after EA, the P200 amplitude of attention on HRC at Cz and Pz was significantly lowered (P<0.05) and that on PEC at Fz was significantly elevated (P<0.05). After EA, the P200 amplitude at Pz was ranked as NEC > PEC > HRC, but in the control group, it showed PEC > HRC at all three observation points and PEC > NEC at Pz. Heroin addicts show attention bias to HRC, which could be significantly reduced by EA intervention, illustrating that EA could effectively inhibit the attention bias to heroin and so might have potential for lowering the relapse rate.
Multiple Sensor Camera for Enhanced Video Capturing
NASA Astrophysics Data System (ADS)
Nagahara, Hajime; Kanki, Yoshinori; Iwai, Yoshio; Yachida, Masahiko
A resolution of camera has been drastically improved under a current request for high-quality digital images. For example, digital still camera has several mega pixels. Although a video camera has the higher frame-rate, the resolution of a video camera is lower than that of still camera. Thus, the high-resolution is incompatible with the high frame rate of ordinary cameras in market. It is difficult to solve this problem by a single sensor, since it comes from physical limitation of the pixel transfer rate. In this paper, we propose a multi-sensor camera for capturing a resolution and frame-rate enhanced video. Common multi-CCDs camera, such as 3CCD color camera, has same CCD for capturing different spectral information. Our approach is to use different spatio-temporal resolution sensors in a single camera cabinet for capturing higher resolution and frame-rate information separately. We build a prototype camera which can capture high-resolution (2588×1958 pixels, 3.75 fps) and high frame-rate (500×500, 90 fps) videos. We also proposed the calibration method for the camera. As one of the application of the camera, we demonstrate an enhanced video (2128×1952 pixels, 90 fps) generated from the captured videos for showing the utility of the camera.
The Proper Motion of the Central Compact Object RX J0822-4300 in the Supernova Remnant Puppis A
NASA Technical Reports Server (NTRS)
Becker, Werner; Prinz, Tobias; Winkler, P. Frank; Petre, Robert
2012-01-01
Using the High Resolution Camera (HRC) aboard the Chandra X-ray Observatory, we have re-examined the proper motion of the central compact object RX J0822-4300 in the supernova remnant Puppis A. New data from 2010 August, combined with three archival data sets from as early as 1999 December, provide a baseline of 3886 days (more than 10 1/2 years) to perform the measurement. Correlating the four positions of RX J0822-4300 measured in each data set implies a projected proper motion of mu = 71 +/- 12 mas/yr. For a distance of 2 kpc this proper motion is equivalent to a recoil velocity of 672 +/- 115 km/s. The position angle is found to be 244 +/- 11 degrees. Both the magnitude and direction of the proper motion are in agreement with RX J0822-4300 originating near the optical expansion center of the supernova remnant. For a displacement of 371 +/- 31 arcsec between its birth place and today's position we deduce an age of (5.2 +/- 1.0) 10(exp 3) yrs for RX J0822-4300. The age inferred from the neutron star proper motion and filament motions can be considered as two independent measurements of the same quantity. They average to 4450 +/- 750 yrs for the age of the supernova remnant Puppis A.
Schmidt, Maria Augusta; Balsanelli, Eduardo; Faoro, Hellison; Cruz, Leonardo M; Wassem, Roseli; de Baura, Valter A; Weiss, Vinícius; Yates, Marshall G; Madeira, Humberto M F; Pereira-Ferrari, Lilian; Fungaro, Maria H P; de Paula, Francine M; Pereira, Luiz F P; Vieira, Luiz G E; Olivares, Fábio L; Pedrosa, Fábio O; de Souza, Emanuel M; Monteiro, Rose A
2012-06-06
Herbaspirillum rubrisubalbicans was first identified as a bacterial plant pathogen, causing the mottled stripe disease in sugarcane. H. rubrisubalbicans can also associate with various plants of economic interest in a non pathogenic manner. A 21 kb DNA region of the H. rubrisubalbicans genome contains a cluster of 26 hrp/hrc genes encoding for the type three secretion system (T3SS) proteins. To investigate the contribution of T3SS to the plant-bacterial interaction process we generated mutant strains of H. rubrisubalbicans M1 carrying a Tn5 insertion in both the hrcN and hrpE genes. H. rubrisulbalbicans hrpE and hrcN mutant strains of the T3SS system failed to cause the mottled stripe disease in the sugarcane susceptible variety B-4362. These mutant strains also did not produce lesions on Vigna unguiculata leaves. Oryza sativa and Zea mays colonization experiments showed that mutations in hrpE and hrcN genes reduced the capacity of H. rubrisulbalbicans to colonize these plants, suggesting that hrpE and hrcN genes are involved in the endophytic colonization. Our results indicate that the T3SS of H. rubrisubalbicans is necessary for the development of the mottled stripe disease and endophytic colonization of rice.
2012-01-01
Background Herbaspirillum rubrisubalbicans was first identified as a bacterial plant pathogen, causing the mottled stripe disease in sugarcane. H. rubrisubalbicans can also associate with various plants of economic interest in a non pathogenic manner. Results A 21 kb DNA region of the H. rubrisubalbicans genome contains a cluster of 26 hrp/hrc genes encoding for the type three secretion system (T3SS) proteins. To investigate the contribution of T3SS to the plant-bacterial interaction process we generated mutant strains of H. rubrisubalbicans M1 carrying a Tn5 insertion in both the hrcN and hrpE genes. H. rubrisulbalbicans hrpE and hrcN mutant strains of the T3SS system failed to cause the mottled stripe disease in the sugarcane susceptible variety B-4362. These mutant strains also did not produce lesions on Vigna unguiculata leaves. Oryza sativa and Zea mays colonization experiments showed that mutations in hrpE and hrcN genes reduced the capacity of H. rubrisulbalbicans to colonize these plants, suggesting that hrpE and hrcN genes are involved in the endophytic colonization. Conclusions Our results indicate that the T3SS of H. rubrisubalbicans is necessary for the development of the mottled stripe disease and endophytic colonization of rice. PMID:22672506
Li, Lei; Li, Rui-Fang; Ming, Zhen-Hua; Lu, Guang-Tao; Tang, Ji-Liang
2017-01-01
Many bacterial pathogens employ the type III secretion system (T3SS) to translocate effector proteins into eukaryotic cells to overcome host defenses. To date, most of our knowledge about the T3SS molecular architecture comes from the studies on animal pathogens. In plant pathogens, nine Hrc proteins are believed to be structural components of the T3SS, of which HrcC and HrcJ form the outer and inner rings of the T3SS, respectively. Here, we demonstrated that a novel outer membrane-bound protein (HpaM) of Xanthomonas campestris pv. campestris is critical for the type III secretion and is structurally and functionally conserved in phytopathogenic Xanthomonas spp. We showed that the C-terminus of HpaM extends into the periplasm to interact physically with HrcJ and the middle part of HpaM interacts physically with HrcC. It is clear that the outer and inner rings compose the main basal body of the T3SS apparatus in animal pathogens. Therefore, we presume that HpaM may act as a T3SS structural component, or play a role in assisting assembling or affecting the stability of the T3SS apparatus. HpaM is a highly prevalent and specific protein in Xanthomonas spp., suggesting that the T3SS of Xanthomonas is distinctive in some aspects from other pathogens. PMID:28198457
Chandra High Resolution Imaging of NGC 1365 and NGC 4151
NASA Astrophysics Data System (ADS)
Wang, Junfeng; Fabbiano, G.; Elvis, M.; Risaliti, G.; Karovska, M.; Zezas, A.; Mazzarella, J. M.; Lord, S.; Howell, J. H.; Mundell, C. G.
2010-07-01
We present Chandra high resolution imaging of the circumnuclear regions of two nearby active galaxies, namely the starburst/AGN composite Seyfert 1.8 NGC 1365 and the archetypal Seyfert 1 NGC 4151. In NGC 1365, the X-ray morphology shows a biconical soft X-ray-emission region extending ~5 kpc in projection from the nucleus, coincident with the optical high-excitation outflows. Chandra HRC imaging of the NGC 4151 nucleus resolves X-ray emission from the 4 arcsec radio jet and the narrow line region (NLR) clouds. Our results demonstrate the unique power of spatially resolved spectroscopy with Chandra, and support previous claims that frequent jet-ISM interaction may explain why jets in Seyfert galaxies appear small, slow, and thermally dominated.
SITE BULLETIN, ATTENUATED ANAEROBIC DECHLORINATION OF GROUNDWATER USING HRC MACTEC - HARDING ESE
A SITE demonstration of the Harding ESE permeable reactive barrier wall (PRBW) was conducted on the contaminated groundwater from the Fisherville Mill site in Grafton, MA beginning June 2000 to July 2003. Installation of the PRBW was accomplished by injecting HRC into a series of...
50 CFR 216.178 - Renewal of Letters of Authorization.
Code of Federal Regulations, 2013 CFR
2013-10-01
... IMPORTING OF MARINE MAMMALS Taking Marine Mammals Incidental to U.S. Navy Training in the Hawaii Range... the HRC or other locations). (2) Findings of the Monitoring Workshop that the Navy will convene in... from the HRC Study Area or other locations, and involving coincident MFAS/HFAS or explosives training...
50 CFR 216.178 - Renewal of Letters of Authorization.
Code of Federal Regulations, 2012 CFR
2012-10-01
... IMPORTING OF MARINE MAMMALS Taking Marine Mammals Incidental to U.S. Navy Training in the Hawaii Range... the HRC or other locations). (2) Findings of the Monitoring Workshop that the Navy will convene in... from the HRC Study Area or other locations, and involving coincident MFAS/HFAS or explosives training...
U.S. EPA, Pesticide Product Label, GRO-WELL MULTI-PURPOSE DUST OR SPRAY, 04/30/1971
2011-04-14
... (' fi ,I;, of l:;~l''', 1\\0 r .. ;t str(':,:s or ,)0n'!" f'o ntlt -1:'1" 1 v wh('11 ,.-cather :,ll! l\\' '-,H'rc' rllI,c:rr lilej\\- t<, occur, D() f)( h'-,,,rC"-, \\"p!\\' (hi·' :'rc,duct 0njv ...
Mediating Hillary Rodham Clinton: Television News Practices and Image-Making in the Postmodern Age.
ERIC Educational Resources Information Center
Parry-Giles, Shawn J.
2000-01-01
Reviews stereotypes of Hillary Rodham Clinton (HRC) in television news. Investigates the significance to image-making of stereotypes, visual deconstruction and reconstruction, close-up shots and spectator positioning, as well as news recycling and repetition. Argues that such strategies reify a mediated collective memory of HRC which is…
This Innovative Technology Evaluation Report documents the results of a demonstration of the hydrogen release compound (HRC®) barrier technology developed by Regenesis Bioremediation Products, Inc., of San Clemente, California. HRC® is a proprietary, food-q...
HIPAA Readiness Collaborative in Hawaii.
Chun, Marva; Forbes, Susan; Gose, Steven; Kumabe, Brenda; Loo, Jeffrey; Nichols, Lorraine; Rosa, Luis; Sherrill, Laura; Turner, Jim
2002-01-01
The vision of Hawaii's HIPAA Readiness Collaborative (HRC) effort is to realize the positive potential of HIPAA through a collaborative process that engages the entire healthcare delivery system. Goals include reducing the cost of healthcare through streamlining, reducing the cost of HIPAA implementation for HRC participants, and improving the interoperability between facilities through use of standard technologies.
Genetic characterization of the Bifidobacterium breve UCC 2003 hrcA locus.
Ventura, Marco; Canchaya, Carlos; Bernini, Valentina; Del Casale, Antonio; Dellaglio, Franco; Neviani, Erasmo; Fitzgerald, Gerald F; van Sinderen, Douwe
2005-12-01
The bacterial heat shock response is characterized by the elevated expression of a number of chaperone complexes and transcriptional regulators, including the DnaJ and the HrcA proteins. Genome analysis of Bifidobacterium breve UCC 2003 revealed a second copy of a dnaJ gene, named dnaJ2, which is flanked by the hrcA gene in a genetic constellation that appears to be unique to the actinobacteria. Phylogenetic analysis using 53 bacterial dnaJ sequences, including both dnaJ1 and dnaJ2 sequences, suggests that these genes have followed a different evolutionary development. Furthermore, the B. breve UCC 2003 dnaJ2 gene seems to be regulated in a manner that is different from that of the previously characterized dnaJ1 gene. The dnaJ2 gene, which was shown to be part of a 2.3-kb bicistronic operon with hrcA, was induced by osmotic shock but not significantly by heat stress. This induction pattern is unlike those of other characterized dnaJ genes and may be indicative of a unique stress adaptation strategy by this commensal microorganism.
Genetic Characterization of the Bifidobacterium breve UCC 2003 hrcA Locus
Ventura, Marco; Canchaya, Carlos; Bernini, Valentina; Del Casale, Antonio; Dellaglio, Franco; Neviani, Erasmo; Fitzgerald, Gerald F.; van Sinderen, Douwe
2005-01-01
The bacterial heat shock response is characterized by the elevated expression of a number of chaperone complexes and transcriptional regulators, including the DnaJ and the HrcA proteins. Genome analysis of Bifidobacterium breve UCC 2003 revealed a second copy of a dnaJ gene, named dnaJ2, which is flanked by the hrcA gene in a genetic constellation that appears to be unique to the actinobacteria. Phylogenetic analysis using 53 bacterial dnaJ sequences, including both dnaJ1 and dnaJ2 sequences, suggests that these genes have followed a different evolutionary development. Furthermore, the B. breve UCC 2003 dnaJ2 gene seems to be regulated in a manner that is different from that of the previously characterized dnaJ1 gene. The dnaJ2 gene, which was shown to be part of a 2.3-kb bicistronic operon with hrcA, was induced by osmotic shock but not significantly by heat stress. This induction pattern is unlike those of other characterized dnaJ genes and may be indicative of a unique stress adaptation strategy by this commensal microorganism. PMID:16332909
Freitas, Tomás T; Calleja-González, Julio; Alarcón, Francisco; Alcaraz, Pedro E
2016-02-01
This study aimed to investigate the acute effects of two different resistance circuit training protocols on basketball players' physical and technical performance and rating of perceived exertion (RPE). In a repeated-measures, crossover experimental design, 9 semiprofessional basketball players performed a Power Circuit Training (PCT; 45% 1RM) and a High-Resistance Circuit Training (HRC; 6RM), on consecutive weeks. Vertical and horizontal jump performance, 3-points shooting accuracy, repeated-sprint ability (RSA), agility, and upper body power output were measured before and after training. The RPE was assessed 20 minutes after resistance training. One-way repeated-measures analysis of variance showed performance decrements in vertical jump height and peak power, horizontal jump distance, 3-points percentage, bench-press power output, RSA total and ideal time, and agility T-Test at total time following HRC, but not PCT (p ≤ 0.05). The RPE was higher in HRC compared with PCT. The results of this study indicated that HRC was perceived as being harder and produced higher fatigue levels, which in turn lowered acute performance. However, low-to-moderate intensity loads did not negatively affect performance. Thus, completing a PCT session may be the most appropriate option before a practice or game as it avoids acute-resistance-training-induced performance decrements. However, if the objective of the basketball session is to develop or perfect technical skills during fatiguing conditions, HRC may be the more suitable option.
A digital gigapixel large-format tile-scan camera.
Ben-Ezra, M
2011-01-01
Although the resolution of single-lens reflex (SLR) and medium-format digital cameras has increased in recent years, applications for cultural-heritage preservation and computational photography require even higher resolutions. Addressing this issue, a large-format cameras' large image planes can achieve very high resolution without compromising pixel size and thus can provide high-quality, high-resolution images.This digital large-format tile scan camera can acquire high-quality, high-resolution images of static scenes. It employs unique calibration techniques and a simple algorithm for focal-stack processing of very large images with significant magnification variations. The camera automatically collects overlapping focal stacks and processes them into a high-resolution, extended-depth-of-field image.
77 FR 11067 - Taking and Importing Marine Mammals; U.S. Navy Training in the Hawaii Range Complex
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... Authorization (LOA) to the U.S. Navy (Navy) to take marine mammals incidental to training and research... the Navy incidental to training and research activities conducted within the Hawaii Range Complex (HRC... training and research activities conducted within the HRC under regulations issued on January 5, 2009 (74...
Rossi, Ciro César; de Oliveira, Lorayne Lauria; de Carvalho Rodrigues, Deivid; Ürményi, Turán Peter; Laport, Marinella Silva; Giambiagi-deMarval, Marcia
2017-08-01
The uropathogen Staphylococcus saprophyticus is an ubiquitous bacterium but little is known about mechanisms that allow its persistence in diverse environments. Here we evaluated S. saprophyticus growth and survival during heat shock, the expression of stress response regulators ctsR and hrcA through qRT-PCR and heat shock protein synthesis through 35 S-Met metabolic labeling. S. saprophyticus does not tolerate temperatures much higher than the optimal 37 °C, as its growth is greatly affected at 42 °C, though viability is maintained up to 48 °C. At 42 °C, the expression of ctsR and hrcA repressor genes approximately triple when compared to 37 °C and continue to increase together with temperature till 48 °C. Expression of hrcA peaks after 20 min of heat shock and decreases significantly after 30 min, indicating that heat stress response regulated by this gene may last 20-30 min. An increase in temperature is accompanied by the synthesis of at least eight proteins, three of which are likely the chaperones DnaK, GroEL and ClpB. In silico analysis indicate that the groEL gene may be regulated by HrcA, clpB by CtsR and dnaK by both repressors. This is the first work to discuss heat stress response in S. saprophyticus and a step forward in the understanding of mechanisms that make this a widespread and emergent pathogen.
Prevalence of type III secretion system in effective biocontrol pseudomonads.
Almario, Juliana; Gobbin, Davide; Défago, Geneviève; Moënne-Loccoz, Yvan; Rezzonico, Fabio
2014-05-01
Functional type III secretion system (T3SS) genes are needed for effective biocontrol of Pythium damping-off of cucumber by Pseudomonas fluorescens KD, but whether biocontrol Pseudomonas strains with T3SS genes display overall a higher plant-protecting activity is unknown. The assessment of 198 biocontrol fluorescent pseudomonads originating from 60 soils worldwide indicated that 32% harbour the ATPase-encoding T3SS gene hrcN, which was most often found in tomato isolates. The hrcN(+) biocontrol strains (and especially those also producing 2,4-diacetylphloroglucinol and displaying 1-aminocyclopropane-1-carboxylate deaminase activity) displayed higher plant-protecting ability in comparison with hrcN(-) biocontrol strains, both in the Pythium/cucumber and Fusarium/cucumber pathosystems. Copyright © 2014 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.
Effect of camera resolution and bandwidth on facial affect recognition.
Cruz, Mario; Cruz, Robyn Flaum; Krupinski, Elizabeth A; Lopez, Ana Maria; McNeeley, Richard M; Weinstein, Ronald S
2004-01-01
This preliminary study explored the effect of camera resolution and bandwidth on facial affect recognition, an important process and clinical variable in mental health service delivery. Sixty medical students and mental health-care professionals were recruited and randomized to four different combinations of commonly used teleconferencing camera resolutions and bandwidths: (1) one chip charged coupling device (CCD) camera, commonly used for VHSgrade taping and in teleconferencing systems costing less than $4,000 with a resolution of 280 lines, and 128 kilobytes per second bandwidth (kbps); (2) VHS and 768 kbps; (3) three-chip CCD camera, commonly used for Betacam (Beta) grade taping and in teleconferencing systems costing more than $4,000 with a resolution of 480 lines, and 128 kbps; and (4) Betacam and 768 kbps. The subjects were asked to identify four facial affects dynamically presented on videotape by an actor and actress presented via a video monitor at 30 frames per second. Two-way analysis of variance (ANOVA) revealed a significant interaction effect for camera resolution and bandwidth (p = 0.02) and a significant main effect for camera resolution (p = 0.006), but no main effect for bandwidth was detected. Post hoc testing of interaction means, using the Tukey Honestly Significant Difference (HSD) test and the critical difference (CD) at the 0.05 alpha level = 1.71, revealed subjects in the VHS/768 kbps (M = 7.133) and VHS/128 kbps (M = 6.533) were significantly better at recognizing the displayed facial affects than those in the Betacam/768 kbps (M = 4.733) or Betacam/128 kbps (M = 6.333) conditions. Camera resolution and bandwidth combinations differ in their capacity to influence facial affect recognition. For service providers, this study's results support the use of VHS cameras with either 768 kbps or 128 kbps bandwidths for facial affect recognition compared to Betacam cameras. The authors argue that the results of this study are a consequence of the VHS camera resolution/bandwidth combinations' ability to improve signal detection (i.e., facial affect recognition) by subjects in comparison to Betacam camera resolution/bandwidth combinations.
Høye, Gudrun; Fridman, Andrei
2013-05-06
Current high-resolution push-broom hyperspectral cameras introduce keystone errors to the captured data. Efforts to correct these errors in hardware severely limit the optical design, in particular with respect to light throughput and spatial resolution, while at the same time the residual keystone often remains large. The mixel camera solves this problem by combining a hardware component--an array of light mixing chambers--with a mathematical method that restores the hyperspectral data to its keystone-free form, based on the data that was recorded onto the sensor with large keystone. A Virtual Camera software, that was developed specifically for this purpose, was used to compare the performance of the mixel camera to traditional cameras that correct keystone in hardware. The mixel camera can collect at least four times more light than most current high-resolution hyperspectral cameras, and simulations have shown that the mixel camera will be photon-noise limited--even in bright light--with a significantly improved signal-to-noise ratio compared to traditional cameras. A prototype has been built and is being tested.
DOT National Transportation Integrated Search
2015-08-01
Cameras are used prolifically to monitor transportation incidents, infrastructure, and congestion. Traditional camera systems often require human monitoring and only offer low-resolution video. Researchers for the Exploratory Advanced Research (EAR) ...
NASA Astrophysics Data System (ADS)
Schmitz, Nicole; Jaumann, Ralf; Coates, Andrew; Griffiths, Andrew; Hauber, Ernst; Trauthan, Frank; Paar, Gerhard; Barnes, Dave; Bauer, Arnold; Cousins, Claire
2010-05-01
Geologic context as a combination of orbital imaging and surface vision, including range, resolution, stereo, and multispectral imaging, is commonly regarded as basic requirement for remote robotic geology and forms the first tier of any multi-instrument strategy for investigating and eventually understanding the geology of a region from a robotic platform. Missions with objectives beyond a pure geologic survey, e.g. exobiology objectives, require goal-oriented operational procedures, where the iterative process of scientific observation, hypothesis, testing, and synthesis, performed via a sol-by-sol data exchange with a remote robot, is supported by a powerful vision system. Beyond allowing a thorough geological mapping of the surface (soil, rocks and outcrops) in 3D, using wide angle stereo imagery, such a system needs to be able to provide detailed visual information on targets of interest in high resolution, thereby enabling the selection of science targets and samples for further analysis with a specialized in-situ instrument suite. Surface vision for ESA's upcoming ExoMars rover will come from a dedicated Panoramic Camera System (PanCam). As integral part of the Pasteur payload package, the PanCam is designed to support the search for evidence of biological processes by obtaining wide angle multispectral stereoscopic panoramic images and high resolution RGB images from the mast of the rover [1]. The camera system will consist of two identical wide-angle cameras (WACs), which are arranged on a common pan-tilt mechanism, with a fixed stereo base length of 50 cm. The WACs are being complemented by a High Resolution Camera (HRC), mounted between the WACs, which allows a magnification of selected targets by a factor of ~8 with respect to the wide-angle optics. The high-resolution images together with the multispectral and stereo capabilities of the camera will be of unprecedented quality for the identification of water-related surface features (such as sedimentary rocks) and form one key to a successful implementation of ESA's multi-level strategy for the ExoMars Reference Surface Mission. A dedicated PanCam Science Implementation Strategy is under development, which connects the PanCam science objectives and needs of the ExoMars Surface Mission with the required investigations, planned measurement approach and sequence, and connected mission requirements. First step of this strategy is obtaining geological context to enable the decision where to send the rover. PanCam (in combination with Wisdom) will be used to obtain ground truth by a thorough geomorphologic mapping of the ExoMars rover's surroundings in near and far range in the form of (1) RGB or monochromatic full (i.e. 360°) or partial stereo panoramas for morphologic and textural information and stereo ranging, (2) mosaics or single images with partly or full multispectral coverage to assess the mineralogy of surface materials as well as their weathering state and possible past or present alteration processes and (3) small-scale high-resolution information on targets/features of interest, and distant or inaccessible sites. This general survey phase will lead to the identification of surface features like outcrops, ridges and troughs and the characterization of different rock and surface units based on their morphology, distribution, and spectral and physical properties. Evidence of water-bearing minerals, water-altered rocks or even water-lain sediments seen in the large-scale wide angle images will then allow for preselecting those targets/features considered relevant for detailed analysis and definition of their geologic context. Detailed characterization and, subsequently, selection of those preselected targets/features for further analysis will then be enabled by color high-resolution imagery, followed by the next tier of contact instruments to enable a decision on whether or not to acquire samples for further analysis. During the following drill/analysis phase, PanCam's High Resolution Camera will characterize the sample in the sample tray and observe the sample discharge into the Core Sample Transfer Mechanism. Key parts of this science strategy have been tested under laboratory conditions in two geology blind tests [2] and during two field test campaigns in Svalbard, using simulated mission conditions, an ExoMars representative Payload (ExoMars and MSL instrument breadboards), and Mars analog settings [3, 4]. The experiences gained are being translated into operational sequences, and, together with the science implementation strategy, form a first version of a PanCam Surface Operations plan. References: [1] Griffiths, A.D. et al. (2006) International Journal of Astrobiology 5 (3): 269-275, doi:10.1017/ S1473550406003387. [2] Pullan, D. et al. (2009) EPSC Abstracts, Vol. 4, EPSC2009-514. [3] Schmitz, N. et al. (2009) Geophysical Research Abstracts, Vol. 11, EGU2009-10621-2. [4] Cousins, C. et al. (2009) EPSC Abstracts, Vol. 4, EPSC2009-813.
Honeth, Louise; Ström, Peter; Ploner, Alexander; Bagger-Sjöbäck, Dan; Rosenhall, Ulf; Nyrén, Olof
2016-01-01
To investigate in this cross-sectional study among Swedish hunters if tobacco use modifies the previously observed association, expressed as prevalence ratio (PR), between unprotected exposure to impulse noise from hunting rifle caliber (HRC) weapons and high-frequency hearing impairment (HFHI). A nationwide cross-sectional epidemiologic study was conducted among Swedish sport hunters in 2012. The study was Internet-based and consisted of a questionnaire and an Internet-based audiometry test. In all, 202 hunters completed a questionnaire regarding the hearing test. Associations were modeled using Poisson regression. Current, daily use of tobacco was reported by 61 hunters (19 used cigarettes, 47 moist snuff, and 5 both). Tobacco users tended to be younger, fire more shots with HRC weapons, and report more hunting days. Their adjusted PR (1-6 unprotected HRC shots versus 0) was 3.2 (1.4-6.7), P < 0.01. Among the nonusers of tobacco, the corresponding PR was 1.3 (0.9-1.8), P = 0.18. P value for the interaction was 0.01. The importance of ear protection could not be quantified among hunters with HRC weapons because our data suggested that the HFHI outcome had led to changes in the use of such protection. Among hunters using weapons with less sound energy, however, no or sporadic use of hearing protection was linked to a 60% higher prevalence of HFHI, relative to habitual use. Tobacco use modifies the association between exposure to unprotected impulse noise from HRC weapons and the probability of having HFHI among susceptible hunters. The mechanisms remain to be clarified, but because the effect modification was apparent also among the users of smokeless tobacco, combustion products may not be critical for this effect.
Outley, Corliss Wilson; Taddese, Abdissa
2006-04-01
To examine the number of food advertisements African American children are exposed to during children's television programming aired on predominantly African American and general television stations. A content analysis was conducted to identify and analyze the health-related content (HRC) and physical activity-related content (PARC) of food advertisements shown during children's television programming. Three sets of television advertisements from 3 stations (Black Entertainment Television, The WB [Warner Bros], and Disney Channel) served as the sample during a 1-week period in July 2005 (July 11-15), from 3 pm to 9 pm. In total, 1098 advertisements were recorded, with 256 food and beverage commercials used for this study. Results indicate that 36.3% of all commercials were based on fast food restaurants, 31.3% were for drinks, 16.8% were for candy, 13.7% were for cereals, and 2.0% were for snacks (percentages do not total 100 because of rounding). Compared with The WB and Disney Channel, Black Entertainment Television had significantly (P=.001) more food and beverage advertisements. Few HRC or PARC advertisements were shown. Of 256 food and beverage commercials, only 8.2% contained HRC and 9.4% had PARC. Also, the HRC and PARC scenes contained messages that were implied vs explicitly talking about the health or physical benefits of the product. African American children are overexposed to numerous types of food and beverage advertisements. These advertisements do not provide an adequate level of positive HRC and PARC messages. Consequently, the messages that are portrayed may undermine efforts to teach African American children about the importance of healthy living and physical activity.
Porotto, Matteo; Rockx, Barry; Yokoyama, Christine C; Talekar, Aparna; Devito, Ilaria; Palermo, Laura M; Liu, Jie; Cortese, Riccardo; Lu, Min; Feldmann, Heinz; Pessi, Antonello; Moscona, Anne
2010-10-28
In the paramyxovirus cell entry process, receptor binding triggers conformational changes in the fusion protein (F) leading to viral and cellular membrane fusion. Peptides derived from C-terminal heptad repeat (HRC) regions in F have been shown to inhibit fusion by preventing formation of the fusogenic six-helix bundle. We recently showed that the addition of a cholesterol group to HRC peptides active against Nipah virus targets these peptides to the membrane where fusion occurs, dramatically increasing their antiviral effect. In this work, we report that unlike the untagged HRC peptides, which bind to the postulated extended intermediate state bridging the viral and cell membranes, the cholesterol tagged HRC-derived peptides interact with F before the fusion peptide inserts into the target cell membrane, thus capturing an earlier stage in the F-activation process. Furthermore, we show that cholesterol tagging renders these peptides active in vivo: the cholesterol-tagged peptides cross the blood brain barrier, and effectively prevent and treat in an established animal model what would otherwise be fatal Nipah virus encephalitis. The in vivo efficacy of cholesterol-tagged peptides, and in particular their ability to penetrate the CNS, suggests that they are promising candidates for the prevention or therapy of infection by Nipah and other lethal paramyxoviruses.
A novel super-resolution camera model
NASA Astrophysics Data System (ADS)
Shao, Xiaopeng; Wang, Yi; Xu, Jie; Wang, Lin; Liu, Fei; Luo, Qiuhua; Chen, Xiaodong; Bi, Xiangli
2015-05-01
Aiming to realize super resolution(SR) to single image and video reconstruction, a super resolution camera model is proposed for the problem that the resolution of the images obtained by traditional cameras behave comparatively low. To achieve this function we put a certain driving device such as piezoelectric ceramics in the camera. By controlling the driving device, a set of continuous low resolution(LR) images can be obtained and stored instantaneity, which reflect the randomness of the displacements and the real-time performance of the storage very well. The low resolution image sequences have different redundant information and some particular priori information, thus it is possible to restore super resolution image factually and effectively. The sample method is used to derive the reconstruction principle of super resolution, which analyzes the possible improvement degree of the resolution in theory. The super resolution algorithm based on learning is used to reconstruct single image and the variational Bayesian algorithm is simulated to reconstruct the low resolution images with random displacements, which models the unknown high resolution image, motion parameters and unknown model parameters in one hierarchical Bayesian framework. Utilizing sub-pixel registration method, a super resolution image of the scene can be reconstructed. The results of 16 images reconstruction show that this camera model can increase the image resolution to 2 times, obtaining images with higher resolution in currently available hardware levels.
Orbital-science investigation: Part C: photogrammetry of Apollo 15 photography
Wu, Sherman S.C.; Schafer, Francis J.; Jordan, Raymond; Nakata, Gary M.; Derick, James L.
1972-01-01
Mapping of large areas of the Moon by photogrammetric methods was not seriously considered until the Apollo 15 mission. In this mission, a mapping camera system and a 61-cm optical-bar high-resolution panoramic camera, as well as a laser altimeter, were used. The mapping camera system comprises a 7.6-cm metric terrain camera and a 7.6-cm stellar camera mounted in a fixed angular relationship (an angle of 96° between the two camera axes). The metric camera has a glass focal-plane plate with reseau grids. The ground-resolution capability from an altitude of 110 km is approximately 20 m. Because of the auxiliary stellar camera and the laser altimeter, the resulting metric photography can be used not only for medium- and small-scale cartographic or topographic maps, but it also can provide a basis for establishing a lunar geodetic network. The optical-bar panoramic camera has a 135- to 180-line resolution, which is approximately 1 to 2 m of ground resolution from an altitude of 110 km. Very large scale specialized topographic maps for supporting geologic studies of lunar-surface features can be produced from the stereoscopic coverage provided by this camera.
Defining the computational structure of the motion detector in Drosophila
Clark, Damon A.; Bursztyn, Limor; Horowitz, Mark; Schnitzer, Mark J.; Clandinin, Thomas R.
2011-01-01
SUMMARY Many animals rely on visual motion detection for survival. Motion information is extracted from spatiotemporal intensity patterns on the retina, a paradigmatic neural computation. A phenomenological model, the Hassenstein-Reichardt Correlator (HRC), relates visual inputs to neural and behavioral responses to motion, but the circuits that implement this computation remain unknown. Using cell-type specific genetic silencing, minimal motion stimuli, and in vivo calcium imaging, we examine two critical HRC inputs. These two pathways respond preferentially to light and dark moving edges. We demonstrate that these pathways perform overlapping but complementary subsets of the computations underlying the HRC. A numerical model implementing differential weighting of these operations displays the observed edge preferences. Intriguingly, these pathways are distinguished by their sensitivities to a stimulus correlation that corresponds to an illusory percept, “reverse phi”, that affects many species. Thus, this computational architecture may be widely used to achieve edge selectivity in motion detection. PMID:21689602
Interseismic Deformation on the San Andreas Fault System
NASA Astrophysics Data System (ADS)
Segall, P.
2001-12-01
Interseismic deformation measurements are most often interpreted in terms of steady slip on buried elastic dislocations. While such models often yield slip-rates that are in reasonable accord with geologic observations, they are: 1) inconsistent with observations of transient deformation following large earthquakes, and 2) tend to predict locking depths significantly deeper than recent large earthquakes. An alternate two-dimensional model of repeating earthquakes that break an elastic plate of thickness H, overlying a viscoelastic half-space with relaxation time tR (Savage and Prescott, 1978) involves 5 parameters; H, tR, t, T, and ˙ {s}, where t is the time since the last quake, T is the earthquake cycle time, and ˙ {s} is the slip-rate. Many parts of the SAF system involve multiple parallel faults, which further increases the number of parameters to be estimated. All hope is not lost, however, if we make use of a priori constraints on slip-rate from geologic studies, and utilize measurements of time dependent strain following the 1906 earthquake, in addition to the present day spatial distribution of deformation-rate. GPS data from the Carrizo Plain segment of the SAF imply a considerably larger relaxation time than inferred from the post-1906 strain-rate transient. This indicates that either the crustal structure differs significantly between northern and central California, or that the simple model is deficient, either due to time-dependent down-dip slip following large earthquakes or non-linear rheology. To test the effect of regional variations in H and tR, I analyze data from the northern San Francisco Bay area (Prescott et al, 2001, JGR), and include the SAF, the Hayward-Rogers Creek (HRC), and Concord-Green Valley faults (CGV). Non-linear optimization using simulated annealing and constrained non-linear least squares yields an optimal model with: H ~ 10 km, tR ~ 34 years, TSAF = 205 years, ˙ {s}SAF ~ 18 mm/yr, tHRC = 225 years, T{ HRC} = 630 years, and ˙ {s}{HRC } ~ 13 mm/yr, ˙ {s}CGV ~ 9 mm/yr. Adding the constraint that the coseismic slip in major Hayward and San Andreas events not exceed 3.0 m and 7.0 m, respectively yields an optimal model with: H ~ 18 km, tR ~ 36 years, TSAF = 280 years, ˙ {s}SAF = 25 mm/yr, tHRC = 225 years, T{ HRC} = 276 years, and ˙ {s}{HRC } ~ 11 mm/yr, ˙ {s}CGV ~ 9 mm/yr. These estimates are in reasonable accord with independent paleoseismic results. The conclusion of this pilot study is that by combining the present day deformation field, post-1906 strain data, and geologic bounds on slip-rate and maximum earthquake slip, we can estimate parameters of considerable geophysical interest, including time since past quakes and average recurrence interval.
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-01-01
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera. PMID:26959023
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-03-04
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera.
NASA Astrophysics Data System (ADS)
Martin, J. C.; Davidson, Kris; Koppelman, M. D.
2006-12-01
During the past decade η Car has brightened markedly, possibly indicating a change of state. Here we summarize photometry gathered by the Hubble Space Telescope (HST) as part of the HST Treasury Project on this object. Our data include Space Telescope Imaging Spectrograph (STIS) CCD acquisition images, Advanced Camera for Surveys HRC images in four filters, and synthetic photometry in flux-calibrated STIS spectra. The HST's spatial resolution allows us to examine the central star separate from the bright circumstellar ejecta. Its apparent brightness continued to increase briskly during 2002-2006, especially after the mid-2003 spectroscopic event. If this trend continues, the central star will soon become brighter than its ejecta, quite different from the state that existed only a few years ago. One precedent may be the rapid change observed in 1938-1953. We conjecture that the star's mass-loss rate has been decreasing throughout the past century. This research was conducted as part of the η Car Hubble Space Telescope Treasury project via grant GO-9973 from the Space Telescope Science Institute. HST is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS5-26555. Some of the data presented in this paper were obtained from the Multimission Archive at the Space Telescope Science Institute (MAST). STScI is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS5-26555. Support for MAST for non-HST data is provided by the NASA Office of Space Science via grant NAG5-7584 and by other grants and contracts.
Collection and Analysis of Crowd Data with Aerial, Rooftop, and Ground Views
2014-11-10
collected these datasets using different aircrafts. Erista 8 HL OctaCopter is a heavy-lift aerial platform capable of using high-resolution cinema ...is another high-resolution camera that is cinema grade and high quality, with the capability of capturing videos with 4K resolution at 30 frames per...292.58 Imaging Systems and Accessories Blackmagic Production Camera 4 Crowd Counting using 4K Cameras High resolution cinema grade digital video
Stereo depth distortions in teleoperation
NASA Technical Reports Server (NTRS)
Diner, Daniel B.; Vonsydow, Marika
1988-01-01
In teleoperation, a typical application of stereo vision is to view a work space located short distances (1 to 3m) in front of the cameras. The work presented here treats converged camera placement and studies the effects of intercamera distance, camera-to-object viewing distance, and focal length of the camera lenses on both stereo depth resolution and stereo depth distortion. While viewing the fronto-parallel plane 1.4 m in front of the cameras, depth errors are measured on the order of 2cm. A geometric analysis was made of the distortion of the fronto-parallel plane of divergence for stereo TV viewing. The results of the analysis were then verified experimentally. The objective was to determine the optimal camera configuration which gave high stereo depth resolution while minimizing stereo depth distortion. It is found that for converged cameras at a fixed camera-to-object viewing distance, larger intercamera distances allow higher depth resolutions, but cause greater depth distortions. Thus with larger intercamera distances, operators will make greater depth errors (because of the greater distortions), but will be more certain that they are not errors (because of the higher resolution).
Kondo, Toru; Matsuoka, Masahiro; Azai, Chihiro; Itoh, Shigeru; Oh-Oka, Hirozo
2016-05-12
Orientations of the FA and FB iron-sulfur (FeS) clusters in a structure-unknown type-I homodimeric heriobacterial reaction center (hRC) were studied in oriented membranes of the thermophilic anaerobic photosynthetic bacterium Heliobacterium modesticaldum by electron paramagnetic resonance (EPR), and compared with those in heterodimeric photosystem I (PS I). The Rieske-type FeS center in the cytochrome b/c complex showed a well-oriented EPR signal. Illumination at 14 K induced an FB(-) signal with g-axes of gz = 2.066, gy = 1.937, and gx = 1.890, tilted at angles of 60°, 60°, and 45°, respectively, with respect to the membrane normal. Chemical reduction with dithionite produced an additional signal of FA(-), which magnetically interacted with FB(-), with gz = 2.046, gy = 1.942, and gx = 1.911 at 30°, 60°, and 90°, respectively. The angles and redox properties of FA(-) and FB(-) in hRC resemble those of FB(-) and FA(-), respectively, in PS I. Therefore, FA and FB in hRC, named after their g-value similarities, seem to be located like FB and FA, not like FA and FB, respectively, in PS I. The reducing side of hRC could resemble those in PS I, if the names of FA and FB are interchanged with each other.
DOE Office of Scientific and Technical Information (OSTI.GOV)
M Porotto; B Rockx; C Yokoyama
2011-12-31
In the paramyxovirus cell entry process, receptor binding triggers conformational changes in the fusion protein (F) leading to viral and cellular membrane fusion. Peptides derived from C-terminal heptad repeat (HRC) regions in F have been shown to inhibit fusion by preventing formation of the fusogenic six-helix bundle. We recently showed that the addition of a cholesterol group to HRC peptides active against Nipah virus targets these peptides to the membrane where fusion occurs, dramatically increasing their antiviral effect. In this work, we report that unlike the untagged HRC peptides, which bind to the postulated extended intermediate state bridging the viralmore » and cell membranes, the cholesterol tagged HRC-derived peptides interact with F before the fusion peptide inserts into the target cell membrane, thus capturing an earlier stage in the F-activation process. Furthermore, we show that cholesterol tagging renders these peptides active in vivo: the cholesterol-tagged peptides cross the blood brain barrier, and effectively prevent and treat in an established animal model what would otherwise be fatal Nipah virus encephalitis. The in vivo efficacy of cholesterol-tagged peptides, and in particular their ability to penetrate the CNS, suggests that they are promising candidates for the prevention or therapy of infection by Nipah and other lethal paramyxoviruses.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramanathan, Arvind; Pullum, Laura L.; Hobson, Tanner C.
Here, we describe a data-driven unsupervised machine learning approach to extract geo-temporal co-occurrence patterns of asthma and the flu from large-scale electronic healthcare reimbursement claims (eHRC) datasets. Specifically, we examine the eHRC data from 2009 to 2010 pandemic H1N1 influenza season and analyze whether different geographic regions within the United States (US) showed an increase in co-occurrence patterns of the flu and asthma. Our analyses reveal that the temporal patterns extracted from the eHRC data show a distinct lag time between the peak incidence of the asthma and the flu. While the increased occurrence of asthma contributed to increased flumore » incidence during the pandemic, this co-occurrence is predominant for female patients. The geo-temporal patterns reveal that the co-occurrence of the flu and asthma are typically concentrated within the south-east US. Further, in agreement with previous studies, large urban areas (such as New York, Miami, and Los Angeles) exhibit co-occurrence patterns that suggest a peak incidence of asthma and flu significantly early in the spring and winter seasons. Together, our data-analytic approach, integrated within the Oak Ridge Bio-surveillance Toolkit platform, demonstrates how eHRC data can provide novel insights into co-occurring disease patterns.« less
Ramanathan, Arvind; Pullum, Laura L.; Hobson, Tanner C.; ...
2015-08-03
Here, we describe a data-driven unsupervised machine learning approach to extract geo-temporal co-occurrence patterns of asthma and the flu from large-scale electronic healthcare reimbursement claims (eHRC) datasets. Specifically, we examine the eHRC data from 2009 to 2010 pandemic H1N1 influenza season and analyze whether different geographic regions within the United States (US) showed an increase in co-occurrence patterns of the flu and asthma. Our analyses reveal that the temporal patterns extracted from the eHRC data show a distinct lag time between the peak incidence of the asthma and the flu. While the increased occurrence of asthma contributed to increased flumore » incidence during the pandemic, this co-occurrence is predominant for female patients. The geo-temporal patterns reveal that the co-occurrence of the flu and asthma are typically concentrated within the south-east US. Further, in agreement with previous studies, large urban areas (such as New York, Miami, and Los Angeles) exhibit co-occurrence patterns that suggest a peak incidence of asthma and flu significantly early in the spring and winter seasons. Together, our data-analytic approach, integrated within the Oak Ridge Bio-surveillance Toolkit platform, demonstrates how eHRC data can provide novel insights into co-occurring disease patterns.« less
Blur spot limitations in distal endoscope sensors
NASA Astrophysics Data System (ADS)
Yaron, Avi; Shechterman, Mark; Horesh, Nadav
2006-02-01
In years past, the picture quality of electronic video systems was limited by the image sensor. In the present, the resolution of miniature image sensors, as in medical endoscopy, is typically superior to the resolution of the optical system. This "excess resolution" is utilized by Visionsense to create stereoscopic vision. Visionsense has developed a single chip stereoscopic camera that multiplexes the horizontal dimension of the image sensor into two (left and right) images, compensates the blur phenomena, and provides additional depth resolution without sacrificing planar resolution. The camera is based on a dual-pupil imaging objective and an image sensor coated by an array of microlenses (a plenoptic camera). The camera has the advantage of being compact, providing simultaneous acquisition of left and right images, and offering resolution comparable to a dual chip stereoscopic camera with low to medium resolution imaging lenses. A stereoscopic vision system provides an improved 3-dimensional perspective of intra-operative sites that is crucial for advanced minimally invasive surgery and contributes to surgeon performance. An additional advantage of single chip stereo sensors is improvement of tolerance to electronic signal noise.
Honeth, Louise; Ström, Peter; Ploner, Alexander; Bagger-Sjöbäck, Dan; Rosenhall, Ulf; Nyrén, Olof
2016-01-01
Aim: To investigate in this cross-sectional study among Swedish hunters if tobacco use modifies the previously observed association, expressed as prevalence ratio (PR), between unprotected exposure to impulse noise from hunting rifle caliber (HRC) weapons and high-frequency hearing impairment (HFHI). Settings and Design: A nationwide cross-sectional epidemiologic study was conducted among Swedish sport hunters in 2012. Materials and Methods: The study was Internet-based and consisted of a questionnaire and an Internet-based audiometry test. Results: In all, 202 hunters completed a questionnaire regarding the hearing test. Associations were modeled using Poisson regression. Current, daily use of tobacco was reported by 61 hunters (19 used cigarettes, 47 moist snuff, and 5 both). Tobacco users tended to be younger, fire more shots with HRC weapons, and report more hunting days. Their adjusted PR (1–6 unprotected HRC shots versus 0) was 3.2 (1.4–6.7), P = 0.01. Among the nonusers of tobacco, the corresponding PR was 1.3 (0.9–1.8), P = 0.18. P value for the interaction was 0.01. The importance of ear protection could not be quantified among hunters with HRC weapons because our data suggested that the HFHI outcome had led to changes in the use of such protection. Among hunters using weapons with less sound energy, however, no or sporadic use of hearing protection was linked to a 60% higher prevalence of HFHI, relative to habitual use. Conclusion: Tobacco use modifies the association between exposure to unprotected impulse noise from HRC weapons and the probability of having HFHI among susceptible hunters. The mechanisms remain to be clarified, but because the effect modification was apparent also among the users of smokeless tobacco, combustion products may not be critical for this effect. PMID:27991471
Joint estimation of high resolution images and depth maps from light field cameras
NASA Astrophysics Data System (ADS)
Ohashi, Kazuki; Takahashi, Keita; Fujii, Toshiaki
2014-03-01
Light field cameras are attracting much attention as tools for acquiring 3D information of a scene through a single camera. The main drawback of typical lenselet-based light field cameras is the limited resolution. This limitation comes from the structure where a microlens array is inserted between the sensor and the main lens. The microlens array projects 4D light field on a single 2D image sensor at the sacrifice of the resolution; the angular resolution and the position resolution trade-off under the fixed resolution of the image sensor. This fundamental trade-off remains after the raw light field image is converted to a set of sub-aperture images. The purpose of our study is to estimate a higher resolution image from low resolution sub-aperture images using a framework of super-resolution reconstruction. In this reconstruction, these sub-aperture images should be registered as accurately as possible. This registration is equivalent to depth estimation. Therefore, we propose a method where super-resolution and depth refinement are performed alternatively. Most of the process of our method is implemented by image processing operations. We present several experimental results using a Lytro camera, where we increased the resolution of a sub-aperture image by three times horizontally and vertically. Our method can produce clearer images compared to the original sub-aperture images and the case without depth refinement.
High-Resolution Mars Camera Test Image of Moon Infrared
2005-09-13
This crescent view of Earth Moon in infrared wavelengths comes from a camera test by NASA Mars Reconnaissance Orbiter spacecraft on its way to Mars. This image was taken by taken by the High Resolution Imaging Science Experiment camera Sept. 8, 2005.
Microchannel plate streak camera
Wang, Ching L.
1989-01-01
An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.
Texton-based super-resolution for achieving high spatiotemporal resolution in hybrid camera system
NASA Astrophysics Data System (ADS)
Kamimura, Kenji; Tsumura, Norimichi; Nakaguchi, Toshiya; Miyake, Yoichi
2010-05-01
Many super-resolution methods have been proposed to enhance the spatial resolution of images by using iteration and multiple input images. In a previous paper, we proposed the example-based super-resolution method to enhance an image through pixel-based texton substitution to reduce the computational cost. In this method, however, we only considered the enhancement of a texture image. In this study, we modified this texton substitution method for a hybrid camera to reduce the required bandwidth of a high-resolution video camera. We applied our algorithm to pairs of high- and low-spatiotemporal-resolution videos, which were synthesized to simulate a hybrid camera. The result showed that the fine detail of the low-resolution video can be reproduced compared with bicubic interpolation and the required bandwidth could be reduced to about 1/5 in a video camera. It was also shown that the peak signal-to-noise ratios (PSNRs) of the images improved by about 6 dB in a trained frame and by 1.0-1.5 dB in a test frame, as determined by comparison with the processed image using bicubic interpolation, and the average PSNRs were higher than those obtained by the well-known Freeman’s patch-based super-resolution method. Compared with that of the Freeman’s patch-based super-resolution method, the computational time of our method was reduced to almost 1/10.
Defining the computational structure of the motion detector in Drosophila.
Clark, Damon A; Bursztyn, Limor; Horowitz, Mark A; Schnitzer, Mark J; Clandinin, Thomas R
2011-06-23
Many animals rely on visual motion detection for survival. Motion information is extracted from spatiotemporal intensity patterns on the retina, a paradigmatic neural computation. A phenomenological model, the Hassenstein-Reichardt correlator (HRC), relates visual inputs to neural activity and behavioral responses to motion, but the circuits that implement this computation remain unknown. By using cell-type specific genetic silencing, minimal motion stimuli, and in vivo calcium imaging, we examine two critical HRC inputs. These two pathways respond preferentially to light and dark moving edges. We demonstrate that these pathways perform overlapping but complementary subsets of the computations underlying the HRC. A numerical model implementing differential weighting of these operations displays the observed edge preferences. Intriguingly, these pathways are distinguished by their sensitivities to a stimulus correlation that corresponds to an illusory percept, "reverse phi," that affects many species. Thus, this computational architecture may be widely used to achieve edge selectivity in motion detection. Copyright © 2011 Elsevier Inc. All rights reserved.
Reference-based phasing using the Haplotype Reference Consortium panel.
Loh, Po-Ru; Danecek, Petr; Palamara, Pier Francesco; Fuchsberger, Christian; A Reshef, Yakir; K Finucane, Hilary; Schoenherr, Sebastian; Forer, Lukas; McCarthy, Shane; Abecasis, Goncalo R; Durbin, Richard; L Price, Alkes
2016-11-01
Haplotype phasing is a fundamental problem in medical and population genetics. Phasing is generally performed via statistical phasing in a genotyped cohort, an approach that can yield high accuracy in very large cohorts but attains lower accuracy in smaller cohorts. Here we instead explore the paradigm of reference-based phasing. We introduce a new phasing algorithm, Eagle2, that attains high accuracy across a broad range of cohort sizes by efficiently leveraging information from large external reference panels (such as the Haplotype Reference Consortium; HRC) using a new data structure based on the positional Burrows-Wheeler transform. We demonstrate that Eagle2 attains a ∼20× speedup and ∼10% increase in accuracy compared to reference-based phasing using SHAPEIT2. On European-ancestry samples, Eagle2 with the HRC panel achieves >2× the accuracy of 1000 Genomes-based phasing. Eagle2 is open source and freely available for HRC-based phasing via the Sanger Imputation Service and the Michigan Imputation Server.
An Example-Based Super-Resolution Algorithm for Selfie Images
William, Jino Hans; Venkateswaran, N.; Narayanan, Srinath; Ramachandran, Sandeep
2016-01-01
A selfie is typically a self-portrait captured using the front camera of a smartphone. Most state-of-the-art smartphones are equipped with a high-resolution (HR) rear camera and a low-resolution (LR) front camera. As selfies are captured by front camera with limited pixel resolution, the fine details in it are explicitly missed. This paper aims to improve the resolution of selfies by exploiting the fine details in HR images captured by rear camera using an example-based super-resolution (SR) algorithm. HR images captured by rear camera carry significant fine details and are used as an exemplar to train an optimal matrix-value regression (MVR) operator. The MVR operator serves as an image-pair priori which learns the correspondence between the LR-HR patch-pairs and is effectively used to super-resolve LR selfie images. The proposed MVR algorithm avoids vectorization of image patch-pairs and preserves image-level information during both learning and recovering process. The proposed algorithm is evaluated for its efficiency and effectiveness both qualitatively and quantitatively with other state-of-the-art SR algorithms. The results validate that the proposed algorithm is efficient as it requires less than 3 seconds to super-resolve LR selfie and is effective as it preserves sharp details without introducing any counterfeit fine details. PMID:27064500
Super-resolution in a defocused plenoptic camera: a wave-optics-based approach.
Sahin, Erdem; Katkovnik, Vladimir; Gotchev, Atanas
2016-03-01
Plenoptic cameras enable the capture of a light field with a single device. However, with traditional light field rendering procedures, they can provide only low-resolution two-dimensional images. Super-resolution is considered to overcome this drawback. In this study, we present a super-resolution method for the defocused plenoptic camera (Plenoptic 1.0), where the imaging system is modeled using wave optics principles and utilizing low-resolution depth information of the scene. We are particularly interested in super-resolution of in-focus and near in-focus scene regions, which constitute the most challenging cases. The simulation results show that the employed wave-optics model makes super-resolution possible for such regions as long as sufficiently accurate depth information is available.
Mars Exploration Rover engineering cameras
Maki, J.N.; Bell, J.F.; Herkenhoff, K. E.; Squyres, S. W.; Kiely, A.; Klimesh, M.; Schwochert, M.; Litwin, T.; Willson, R.; Johnson, Aaron H.; Maimone, M.; Baumgartner, E.; Collins, A.; Wadsworth, M.; Elliot, S.T.; Dingizian, A.; Brown, D.; Hagerott, E.C.; Scherr, L.; Deen, R.; Alexander, D.; Lorre, J.
2003-01-01
NASA's Mars Exploration Rover (MER) Mission will place a total of 20 cameras (10 per rover) onto the surface of Mars in early 2004. Fourteen of the 20 cameras are designated as engineering cameras and will support the operation of the vehicles on the Martian surface. Images returned from the engineering cameras will also be of significant importance to the scientific community for investigative studies of rock and soil morphology. The Navigation cameras (Navcams, two per rover) are a mast-mounted stereo pair each with a 45?? square field of view (FOV) and an angular resolution of 0.82 milliradians per pixel (mrad/pixel). The Hazard Avoidance cameras (Hazcams, four per rover) are a body-mounted, front- and rear-facing set of stereo pairs, each with a 124?? square FOV and an angular resolution of 2.1 mrad/pixel. The Descent camera (one per rover), mounted to the lander, has a 45?? square FOV and will return images with spatial resolutions of ???4 m/pixel. All of the engineering cameras utilize broadband visible filters and 1024 x 1024 pixel detectors. Copyright 2003 by the American Geophysical Union.
High-Resolution Large Field-of-View FUV Compact Camera
NASA Technical Reports Server (NTRS)
Spann, James F.
2006-01-01
The need for a high resolution camera with a large field of view and capable to image dim emissions in the far-ultraviolet is driven by the widely varying intensities of FUV emissions and spatial/temporal scales of phenomena of interest in the Earth% ionosphere. In this paper, the concept of a camera is presented that is designed to achieve these goals in a lightweight package with sufficient visible light rejection to be useful for dayside and nightside emissions. The camera employs the concept of self-filtering to achieve good spectral resolution tuned to specific wavelengths. The large field of view is sufficient to image the Earth's disk at Geosynchronous altitudes and capable of a spatial resolution of >20 km. The optics and filters are emphasized.
Pulsed-neutron imaging by a high-speed camera and center-of-gravity processing
NASA Astrophysics Data System (ADS)
Mochiki, K.; Uragaki, T.; Koide, J.; Kushima, Y.; Kawarabayashi, J.; Taketani, A.; Otake, Y.; Matsumoto, Y.; Su, Y.; Hiroi, K.; Shinohara, T.; Kai, T.
2018-01-01
Pulsed-neutron imaging is attractive technique in the research fields of energy-resolved neutron radiography and RANS (RIKEN) and RADEN (J-PARC/JAEA) are small and large accelerator-driven pulsed-neutron facilities for its imaging, respectively. To overcome the insuficient spatial resolution of the conunting type imaging detectors like μ NID, nGEM and pixelated detectors, camera detectors combined with a neutron color image intensifier were investigated. At RANS center-of-gravity technique was applied to spots image obtained by a CCD camera and the technique was confirmed to be effective for improving spatial resolution. At RADEN a high-frame-rate CMOS camera was used and super resolution technique was applied and it was recognized that the spatial resolution was futhermore improved.
Goodwin, William H
2017-09-01
DNA analysis was first applied to the identification of victims of armed conflicts and other situations of violence (ACOSV) in the mid-1990s, starting in South America and the Balkans. Argentina was the first country to establish a genetic database specifically developed to identify disappeared children. Following on from these programs the early 2000s marked major programs, using a largely DNA-led approach, identifying missing persons in the Balkans and following the attack on the World Trade Center in New York. These two identification programs significantly expanded the magnitude of events to which DNA analysis was used to help provide the identity of missing persons. Guidelines developed by Interpol (2014) [1] related to best practice for identification of human remains following DVI type scenarios have been widely disseminated around the forensic community; in numerous cases these guidelines have been adopted or incorporated into national guidelines/standards/practice. However, given the complexity of many humanitarian contexts in which forensic science is employed there is a lack of internationally accepted guidelines, related to these contexts, for authorities to reference. In response the Argentine government's Human Rights Division in the Ministry of Foreign Affairs and Worship (MREC) proposed that the United Nations (UN) should promote best practice in the use of forensic genetics in humanitarian forensic action: this was adopted by the UN in Resolutions A/HRC/RES/10/26 and A/HRC/RES/15/5. Following on from the adoption of the resolutions MREC has coordinated, with the support of the International Committee of the Red Cross (ICRC), the drafting of a set of guidelines (MREC, ICRC, 2014) [2], with input from national and international agencies. To date the guidelines have been presented to South America's MERCOSUR and the UN and have been disseminated to interested parties. Copyright © 2017 Elsevier B.V. All rights reserved.
Popovic, Kosta; McKisson, Jack E.; Kross, Brian; Lee, Seungjoon; McKisson, John; Weisenberger, Andrew G.; Proffitt, James; Stolin, Alexander; Majewski, Stan; Williams, Mark B.
2017-01-01
This paper describes the development of a hand-held gamma camera for intraoperative surgical guidance that is based on silicon photomultiplier (SiPM) technology. The camera incorporates a cerium doped lanthanum bromide (LaBr3:Ce) plate scintillator, an array of 80 SiPM photodetectors and a two-layer parallel-hole collimator. The field of view is circular with a 60 mm diameter. The disk-shaped camera housing is 75 mm in diameter, approximately 40.5 mm thick and has a mass of only 1.4 kg, permitting either hand-held or arm-mounted use. All camera components are integrated on a mobile cart that allows easy transport. The camera was developed for use in surgical procedures including determination of the location and extent of primary carcinomas, detection of secondary lesions and sentinel lymph node biopsy (SLNB). Here we describe the camera design and its principal operating characteristics, including spatial resolution, energy resolution, sensitivity uniformity, and geometric linearity. The gamma camera has an intrinsic spatial resolution of 4.2 mm FWHM, an energy resolution of 21.1 % FWHM at 140 keV, and a sensitivity of 481 and 73 cps/MBq when using the single- and double-layer collimators, respectively. PMID:28286345
Research on a solid state-streak camera based on an electro-optic crystal
NASA Astrophysics Data System (ADS)
Wang, Chen; Liu, Baiyu; Bai, Yonglin; Bai, Xiaohong; Tian, Jinshou; Yang, Wenzheng; Xian, Ouyang
2006-06-01
With excellent temporal resolution ranging from nanosecond to sub-picoseconds, a streak camera is widely utilized in measuring ultrafast light phenomena, such as detecting synchrotron radiation, examining inertial confinement fusion target, and making measurements of laser-induced discharge. In combination with appropriate optics or spectroscope, the streak camera delivers intensity vs. position (or wavelength) information on the ultrafast process. The current streak camera is based on a sweep electric pulse and an image converting tube with a wavelength-sensitive photocathode ranging from the x-ray to near infrared region. This kind of streak camera is comparatively costly and complex. This paper describes the design and performance of a new-style streak camera based on an electro-optic crystal with large electro-optic coefficient. Crystal streak camera accomplishes the goal of time resolution by direct photon beam deflection using the electro-optic effect which can replace the current streak camera from the visible to near infrared region. After computer-aided simulation, we design a crystal streak camera which has the potential of time resolution between 1ns and 10ns.Some further improvements in sweep electric circuits, a crystal with a larger electro-optic coefficient, for example LN (γ 33=33.6×10 -12m/v) and the optimal optic system may lead to better time resolution less than 1ns.
Performance of the Tachyon Time-of-Flight PET Camera
NASA Astrophysics Data System (ADS)
Peng, Q.; Choong, W.-S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.
2015-02-01
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm2 side of 6.15 ×6.15 ×25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.
Performance of the Tachyon Time-of-Flight PET Camera.
Peng, Q; Choong, W-S; Vu, C; Huber, J S; Janecek, M; Wilson, D; Huesman, R H; Qi, Jinyi; Zhou, Jian; Moses, W W
2015-02-01
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 × 25 mm 2 side of 6.15 × 6.15 × 25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.
Performance of the Tachyon Time-of-Flight PET Camera
Peng, Q.; Choong, W.-S.; Vu, C.; Huber, J. S.; Janecek, M.; Wilson, D.; Huesman, R. H.; Qi, Jinyi; Zhou, Jian; Moses, W. W.
2015-01-01
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon’s detector module is optimized for timing by coupling the 6.15 × 25 mm2 side of 6.15 × 6.15 × 25 mm3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/− ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. The results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3. PMID:26594057
Performance of the Tachyon Time-of-Flight PET Camera
Peng, Q.; Choong, W. -S.; Vu, C.; ...
2015-01-23
We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according tomore » the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.« less
Super-Resolution in Plenoptic Cameras Using FPGAs
Pérez, Joel; Magdaleno, Eduardo; Pérez, Fernando; Rodríguez, Manuel; Hernández, David; Corrales, Jaime
2014-01-01
Plenoptic cameras are a new type of sensor that extend the possibilities of current commercial cameras allowing 3D refocusing or the capture of 3D depths. One of the limitations of plenoptic cameras is their limited spatial resolution. In this paper we describe a fast, specialized hardware implementation of a super-resolution algorithm for plenoptic cameras. The algorithm has been designed for field programmable graphic array (FPGA) devices using VHDL (very high speed integrated circuit (VHSIC) hardware description language). With this technology, we obtain an acceleration of several orders of magnitude using its extremely high-performance signal processing capability through parallelism and pipeline architecture. The system has been developed using generics of the VHDL language. This allows a very versatile and parameterizable system. The system user can easily modify parameters such as data width, number of microlenses of the plenoptic camera, their size and shape, and the super-resolution factor. The speed of the algorithm in FPGA has been successfully compared with the execution using a conventional computer for several image sizes and different 3D refocusing planes. PMID:24841246
Super-resolution in plenoptic cameras using FPGAs.
Pérez, Joel; Magdaleno, Eduardo; Pérez, Fernando; Rodríguez, Manuel; Hernández, David; Corrales, Jaime
2014-05-16
Plenoptic cameras are a new type of sensor that extend the possibilities of current commercial cameras allowing 3D refocusing or the capture of 3D depths. One of the limitations of plenoptic cameras is their limited spatial resolution. In this paper we describe a fast, specialized hardware implementation of a super-resolution algorithm for plenoptic cameras. The algorithm has been designed for field programmable graphic array (FPGA) devices using VHDL (very high speed integrated circuit (VHSIC) hardware description language). With this technology, we obtain an acceleration of several orders of magnitude using its extremely high-performance signal processing capability through parallelism and pipeline architecture. The system has been developed using generics of the VHDL language. This allows a very versatile and parameterizable system. The system user can easily modify parameters such as data width, number of microlenses of the plenoptic camera, their size and shape, and the super-resolution factor. The speed of the algorithm in FPGA has been successfully compared with the execution using a conventional computer for several image sizes and different 3D refocusing planes.
Improved spatial resolution of luminescence images acquired with a silicon line scanning camera
NASA Astrophysics Data System (ADS)
Teal, Anthony; Mitchell, Bernhard; Juhl, Mattias K.
2018-04-01
Luminescence imaging is currently being used to provide spatially resolved defect in high volume silicon solar cell production. One option to obtain the high throughput required for on the fly detection is the use a silicon line scan cameras. However, when using a silicon based camera, the spatial resolution is reduced as a result of the weakly absorbed light scattering within the camera's chip. This paper address this issue by applying deconvolution from a measured point spread function. This paper extends the methods for determining the point spread function of a silicon area camera to a line scan camera with charge transfer. The improvement in resolution is quantified in the Fourier domain and in spatial domain on an image of a multicrystalline silicon brick. It is found that light spreading beyond the active sensor area is significant in line scan sensors, but can be corrected for through normalization of the point spread function. The application of this method improves the raw data, allowing effective detection of the spatial resolution of defects in manufacturing.
Applying and extending ISO/TC42 digital camera resolution standards to mobile imaging products
NASA Astrophysics Data System (ADS)
Williams, Don; Burns, Peter D.
2007-01-01
There are no fundamental differences between today's mobile telephone cameras and consumer digital still cameras that suggest many existing ISO imaging performance standards do not apply. To the extent that they have lenses, color filter arrays, detectors, apertures, image processing, and are hand held, there really are no operational or architectural differences. Despite this, there are currently differences in the levels of imaging performance. These are driven by physical and economic constraints, and image-capture conditions. Several ISO standards for resolution, well established for digital consumer digital cameras, require care when applied to the current generation of cell phone cameras. In particular, accommodation of optical flare, shading non-uniformity and distortion are recommended. We offer proposals for the application of existing ISO imaging resolution performance standards to mobile imaging products, and suggestions for extending performance standards to the characteristic behavior of camera phones.
Optical analysis of a compound quasi-microscope for planetary landers
NASA Technical Reports Server (NTRS)
Wall, S. D.; Burcher, E. E.; Huck, F. O.
1974-01-01
A quasi-microscope concept, consisting of facsimile camera augmented with an auxiliary lens as a magnifier, was introduced and analyzed. The performance achievable with this concept was primarily limited by a trade-off between resolution and object field; this approach leads to a limiting resolution of 20 microns when used with the Viking lander camera (which has an angular resolution of 0.04 deg). An optical system is analyzed which includes a field lens between camera and auxiliary lens to overcome this limitation. It is found that this system, referred to as a compound quasi-microscope, can provide improved resolution (to about 2 microns ) and a larger object field. However, this improvement is at the expense of increased complexity, special camera design requirements, and tighter tolerances on the distances between optical components.
Andrade, Maxuel O.; Farah, Chuck S.; Wang, Nian
2014-01-01
The RsmA/CsrA family of the post-transcriptional regulators of bacteria is involved in the regulation of many cellular processes, including pathogenesis. In this study, we demonstrated that rsmA not only is required for the full virulence of the phytopathogenic bacterium Xanthomonas citri subsp. citri (XCC) but also contributes to triggering the hypersensitive response (HR) in non-host plants. Deletion of rsmA resulted in significantly reduced virulence in the host plant sweet orange and a delayed and weakened HR in the non-host plant Nicotiana benthamiana. Microarray, quantitative reverse-transcription PCR, western-blotting, and GUS assays indicated that RsmA regulates the expression of the type 3 secretion system (T3SS) at both transcriptional and post-transcriptional levels. The regulation of T3SS by RsmA is a universal phenomenon in T3SS-containing bacteria, but the specific mechanism seems to depend on the interaction between a particular bacterium and its hosts. For Xanthomonads, the mechanism by which RsmA activates T3SS remains unknown. Here, we show that RsmA activates the expression of T3SS-encoding hrp/hrc genes by directly binding to the 5′ untranslated region (UTR) of hrpG, the master regulator of the hrp/hrc genes in XCC. RsmA stabilizes hrpG mRNA, leading to increased accumulation of HrpG proteins and subsequently, the activation of hrp/hrc genes. The activation of the hrp/hrc genes by RsmA via HrpG was further supported by the observation that ectopic overexpression of hrpG in an rsmA mutant restored its ability to cause disease in host plants and trigger HR in non-host plants. RsmA also stabilizes the transcripts of another T3SS-associated hrpD operon by directly binding to the 5′ UTR region. Taken together, these data revealed that RsmA primarily activates T3SS by acting as a positive regulator of hrpG and that this regulation is critical to the pathogenicity of XCC. PMID:24586158
Super-resolved refocusing with a plenoptic camera
NASA Astrophysics Data System (ADS)
Zhou, Zhiliang; Yuan, Yan; Bin, Xiangli; Qian, Lulu
2011-03-01
This paper presents an approach to enhance the resolution of refocused images by super resolution methods. In plenoptic imaging, we demonstrate that the raw sensor image can be divided to a number of low-resolution angular images with sub-pixel shifts between each other. The sub-pixel shift, which defines the super-resolving ability, is mathematically derived by considering the plenoptic camera as equivalent camera arrays. We implement simulation to demonstrate the imaging process of a plenoptic camera. A high-resolution image is then reconstructed using maximum a posteriori (MAP) super resolution algorithms. Without other degradation effects in simulation, the super resolved image achieves a resolution as high as predicted by the proposed model. We also build an experimental setup to acquire light fields. With traditional refocusing methods, the image is rendered at a rather low resolution. In contrast, we implement the super-resolved refocusing methods and recover an image with more spatial details. To evaluate the performance of the proposed method, we finally compare the reconstructed images using image quality metrics like peak signal to noise ratio (PSNR).
Toward an image compression algorithm for the high-resolution electronic still camera
NASA Technical Reports Server (NTRS)
Nerheim, Rosalee
1989-01-01
Taking pictures with a camera that uses a digital recording medium instead of film has the advantage of recording and transmitting images without the use of a darkroom or a courier. However, high-resolution images contain an enormous amount of information and strain data-storage systems. Image compression will allow multiple images to be stored in the High-Resolution Electronic Still Camera. The camera is under development at Johnson Space Center. Fidelity of the reproduced image and compression speed are of tantamount importance. Lossless compression algorithms are fast and faithfully reproduce the image, but their compression ratios will be unacceptably low due to noise in the front end of the camera. Future efforts will include exploring methods that will reduce the noise in the image and increase the compression ratio.
The Chandra Source Catalog: X-ray Aperture Photometry
NASA Astrophysics Data System (ADS)
Kashyap, Vinay; Primini, F. A.; Glotfelty, K. J.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, I. N.; Evans, J. D.; Fabbiano, G.; Galle, E. C.; Gibbs, D. G., II; Grier, J. D.; Hain, R.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McCollough, M. L.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Rots, A. H.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; van Stone, D. W.; Winkelman, S. L.; Zografou, P.
2009-09-01
The Chandra Source Catalog (CSC) represents a reanalysis of the entire ACIS and HRC imaging observations over the 9-year Chandra mission. We describe here the method by which fluxes are measured for detected sources. Source detection is carried out on a uniform basis, using the CIAO tool wavdetect. Source fluxes are estimated post-facto using a Bayesian method that accounts for background, spatial resolution effects, and contamination from nearby sources. We use gamma-function prior distributions, which could be either non-informative, or in case there exist previous observations of the same source, strongly informative. The current implementation is however limited to non-informative priors. The resulting posterior probability density functions allow us to report the flux and a robust credible range on it.
NASA Technical Reports Server (NTRS)
Clegg, R. H.; Scherz, J. P.
1975-01-01
Successful aerial photography depends on aerial cameras providing acceptable photographs within cost restrictions of the job. For topographic mapping where ultimate accuracy is required only large format mapping cameras will suffice. For mapping environmental patterns of vegetation, soils, or water pollution, 9-inch cameras often exceed accuracy and cost requirements, and small formats may be better. In choosing the best camera for environmental mapping, relative capabilities and costs must be understood. This study compares resolution, photo interpretation potential, metric accuracy, and cost of 9-inch, 70mm, and 35mm cameras for obtaining simultaneous color and color infrared photography for environmental mapping purposes.
NASA Technical Reports Server (NTRS)
Diner, Daniel B. (Inventor)
1989-01-01
A method and apparatus is developed for obtaining a stereo image with reduced depth distortion and optimum depth resolution. Static and dynamic depth distortion and depth resolution tradeoff is provided. Cameras obtaining the images for a stereo view are converged at a convergence point behind the object to be presented in the image, and the collection-surface-to-object distance, the camera separation distance, and the focal lengths of zoom lenses for the cameras are all increased. Doubling the distances cuts the static depth distortion in half while maintaining image size and depth resolution. Dynamic depth distortion is minimized by panning a stereo view-collecting camera system about a circle which passes through the convergence point and the camera's first nodal points. Horizontal field shifting of the television fields on a television monitor brings both the monitor and the stereo views within the viewer's limit of binocular fusion.
Quasi-microscope concept for planetary missions.
Huck, F O; Arvidson, R E; Burcher, E E; Giat, O; Wall, S D
1977-09-01
Viking lander cameras have returned stereo and multispectral views of the Martian surface with a resolution that approaches 2 mm/lp in the near field. A two-orders-of-magnitude increase in resolution could be obtained for collected surface samples by augmenting these cameras with auxiliary optics that would neither impose special camera design requirements nor limit the cameras field of view of the terrain. Quasi-microscope images would provide valuable data on the physical and chemical characteristics of planetary regoliths.
Single lens 3D-camera with extended depth-of-field
NASA Astrophysics Data System (ADS)
Perwaß, Christian; Wietzke, Lennart
2012-03-01
Placing a micro lens array in front of an image sensor transforms a normal camera into a single lens 3D camera, which also allows the user to change the focus and the point of view after a picture has been taken. While the concept of such plenoptic cameras is known since 1908, only recently the increased computing power of low-cost hardware and the advances in micro lens array production, have made the application of plenoptic cameras feasible. This text presents a detailed analysis of plenoptic cameras as well as introducing a new type of plenoptic camera with an extended depth of field and a maximal effective resolution of up to a quarter of the sensor resolution.
Texture-adaptive hyperspectral video acquisition system with a spatial light modulator
NASA Astrophysics Data System (ADS)
Fang, Xiaojing; Feng, Jiao; Wang, Yongjin
2014-10-01
We present a new hybrid camera system based on spatial light modulator (SLM) to capture texture-adaptive high-resolution hyperspectral video. The hybrid camera system records a hyperspectral video with low spatial resolution using a gray camera and a high-spatial resolution video using a RGB camera. The hyperspectral video is subsampled by the SLM. The subsampled points can be adaptively selected according to the texture characteristic of the scene by combining with digital imaging analysis and computational processing. In this paper, we propose an adaptive sampling method utilizing texture segmentation and wavelet transform (WT). We also demonstrate the effectiveness of the sampled pattern on the SLM with the proposed method.
NASA Astrophysics Data System (ADS)
Beuermann, K.; Burwitz, V.; Rauch, T.
2006-11-01
Context: .The absolute calibration of space-borne instruments in the soft X-ray regime rests strongly on model spectra of hot white dwarfs. Aims: .We analyze the Chandra LETG+HRC observations of the white dwarfs HZ43 A and Sirius B and of the neutron star RX J185635-3754 with the aim of resolving current uncertainties in the soft X-ray spectral fluxes and photospheric parameters of the three stars. We apply the derived photon spectra to a cross-calibration of the LETG+HRC-S with the short-wavelength EUVE spectrometer and the ROSAT PSPC. Methods: .We tie HZ43 A to the flux of RX J1856 in the 44-48 Å range and perform a simultaneous least squares fit to the LETG+HRC spectra of the three stars. This allows us to determine an internally consistent set of spectral energy distributions and an empirically derived wavelength-dependent correction to the LETG+HRC-S effective area. We employ NLTE model atmospheres calculated with TMAP for the white dwarfs and a two-blackbody model for RX J1856, tied to the respective optical fluxes. Results: .The two-blackbody model for RX J1856 features a hot spot on a cooler star and yields kT_spot=62.8±0.4 eV and kT_star=32.3±0.7 eV with a stellar angular radius as seen from infinity of 0.1371±0.0010 km pc-1. For HZ43 A, our fit yields T_eff = 51 126± 660 K and log g=7.90±0.080 (cgs) with anti-correlated errors (1-σ) which include not only the statistical but also the systematic uncertainties of the fit. HZ43AB displays a previously detected bremsstrahlung component with a temperature kT≃ 0.6 keV. For Sirius B, we find T_eff = 24 923± 115 K for fixed log g = 8.6. The calibration of the short-wavelength EUVE spectrometer differs from that of the LETG+HRC-S by 15± 7%. The ROSAT PSPC is found to be correctly calibrated within a few percent and reports of a major miscalibration are unfounded. Conclusions: .We have obtained improved parameters for RX J185635-3754, HZ43 A, and Sirius B which fit the observations from the optical to the soft X-ray regime. Our approach allows us to quote their absolute spectral fluxes at selected wavelengths which may aid the calibration of other space-borne instruments.
NASA Astrophysics Data System (ADS)
Mundermann, Lars; Mundermann, Annegret; Chaudhari, Ajit M.; Andriacchi, Thomas P.
2005-01-01
Anthropometric parameters are fundamental for a wide variety of applications in biomechanics, anthropology, medicine and sports. Recent technological advancements provide methods for constructing 3D surfaces directly. Of these new technologies, visual hull construction may be the most cost-effective yet sufficiently accurate method. However, the conditions influencing the accuracy of anthropometric measurements based on visual hull reconstruction are unknown. The purpose of this study was to evaluate the conditions that influence the accuracy of 3D shape-from-silhouette reconstruction of body segments dependent on number of cameras, camera resolution and object contours. The results demonstrate that the visual hulls lacked accuracy in concave regions and narrow spaces, but setups with a high number of cameras reconstructed a human form with an average accuracy of 1.0 mm. In general, setups with less than 8 cameras yielded largely inaccurate visual hull constructions, while setups with 16 and more cameras provided good volume estimations. Body segment volumes were obtained with an average error of 10% at a 640x480 resolution using 8 cameras. Changes in resolution did not significantly affect the average error. However, substantial decreases in error were observed with increasing number of cameras (33.3% using 4 cameras; 10.5% using 8 cameras; 4.1% using 16 cameras; 1.2% using 64 cameras).
On the resolution of plenoptic PIV
NASA Astrophysics Data System (ADS)
Deem, Eric A.; Zhang, Yang; Cattafesta, Louis N.; Fahringer, Timothy W.; Thurow, Brian S.
2016-08-01
Plenoptic PIV offers a simple, single camera solution for volumetric velocity measurements of fluid flow. However, due to the novel manner in which the particle images are acquired and processed, few references exist to aid in determining the resolution limits of the measurements. This manuscript provides a framework for determining the spatial resolution of plenoptic PIV based on camera design and experimental parameters. This information can then be used to determine the smallest length scales of flows that are observable by plenoptic PIV, the dynamic range of plenoptic PIV, and the corresponding uncertainty in plenoptic PIV measurements. A simplified plenoptic camera is illustrated to provide the reader with a working knowledge of the method in which the light field is recorded. Then, operational considerations are addressed. This includes a derivation of the depth resolution in terms of the design parameters of the camera. Simulated volume reconstructions are presented to validate the derived limits. It is found that, while determining the lateral resolution is relatively straightforward, many factors affect the resolution along the optical axis. These factors are addressed and suggestions are proposed for improving performance.
High-Resolution Mars Camera Test Image of Moon (Infrared)
NASA Technical Reports Server (NTRS)
2005-01-01
This crescent view of Earth's Moon in infrared wavelengths comes from a camera test by NASA's Mars Reconnaissance Orbiter spacecraft on its way to Mars. The mission's High Resolution Imaging Science Experiment camera took the image on Sept. 8, 2005, while at a distance of about 10 million kilometers (6 million miles) from the Moon. The dark feature on the right is Mare Crisium. From that distance, the Moon would appear as a star-like point of light to the unaided eye. The test verified the camera's focusing capability and provided an opportunity for calibration. The spacecraft's Context Camera and Optical Navigation Camera also performed as expected during the test. The Mars Reconnaissance Orbiter, launched on Aug. 12, 2005, is on course to reach Mars on March 10, 2006. After gradually adjusting the shape of its orbit for half a year, it will begin its primary science phase in November 2006. From the mission's planned science orbit about 300 kilometers (186 miles) above the surface of Mars, the high resolution camera will be able to discern features as small as one meter or yard across.Potential for application of an acoustic camera in particle tracking velocimetry.
Wu, Fu-Chun; Shao, Yun-Chuan; Wang, Chi-Kuei; Liou, Jim
2008-11-01
We explored the potential and limitations for applying an acoustic camera as the imaging instrument of particle tracking velocimetry. The strength of the acoustic camera is its usability in low-visibility environments where conventional optical cameras are ineffective, while its applicability is limited by lower temporal and spatial resolutions. We conducted a series of experiments in which acoustic and optical cameras were used to simultaneously image the rotational motion of tracer particles, allowing for a comparison of the acoustic- and optical-based velocities. The results reveal that the greater fluctuations associated with the acoustic-based velocities are primarily attributed to the lower temporal resolution. The positive and negative biases induced by the lower spatial resolution are balanced, with the positive ones greater in magnitude but the negative ones greater in quantity. These biases reduce with the increase in the mean particle velocity and approach minimum as the mean velocity exceeds the threshold value that can be sensed by the acoustic camera.
Chrominance watermark for mobile applications
NASA Astrophysics Data System (ADS)
Reed, Alastair; Rogers, Eliot; James, Dan
2010-01-01
Creating an imperceptible watermark which can be read by a broad range of cell phone cameras is a difficult problem. The problems are caused by the inherently low resolution and noise levels of typical cell phone cameras. The quality limitations of these devices compared to a typical digital camera are caused by the small size of the cell phone and cost trade-offs made by the manufacturer. In order to achieve this, a low resolution watermark is required which can be resolved by a typical cell phone camera. The visibility of a traditional luminance watermark was too great at this lower resolution, so a chrominance watermark was developed. The chrominance watermark takes advantage of the relatively low sensitivity of the human visual system to chrominance changes. This enables a chrominance watermark to be inserted into an image which is imperceptible to the human eye but can be read using a typical cell phone camera. Sample images will be presented showing images with a very low visibility which can be easily read by a typical cell phone camera.
Restoring the spatial resolution of refocus images on 4D light field
NASA Astrophysics Data System (ADS)
Lim, JaeGuyn; Park, ByungKwan; Kang, JooYoung; Lee, SeongDeok
2010-01-01
This paper presents the method for generating a refocus image with restored spatial resolution on a plenoptic camera, which functions controlling the depth of field after capturing one image unlike a traditional camera. It is generally known that the camera captures 4D light field (angular and spatial information of light) within a limited 2D sensor and results in reducing 2D spatial resolution due to inevitable 2D angular data. That's the reason why a refocus image is composed of a low spatial resolution compared with 2D sensor. However, it has recently been known that angular data contain sub-pixel spatial information such that the spatial resolution of 4D light field can be increased. We exploit the fact for improving the spatial resolution of a refocus image. We have experimentally scrutinized that the spatial information is different according to the depth of objects from a camera. So, from the selection of refocused regions (corresponding depth), we use corresponding pre-estimated sub-pixel spatial information for reconstructing spatial resolution of the regions. Meanwhile other regions maintain out-of-focus. Our experimental results show the effect of this proposed method compared to existing method.
Design of the high resolution optical instrument for the Pleiades HR Earth observation satellites
NASA Astrophysics Data System (ADS)
Lamard, Jean-Luc; Gaudin-Delrieu, Catherine; Valentini, David; Renard, Christophe; Tournier, Thierry; Laherrere, Jean-Marc
2017-11-01
As part of its contribution to Earth observation from space, ALCATEL SPACE designed, built and tested the High Resolution cameras for the European intelligence satellites HELIOS I and II. Through these programmes, ALCATEL SPACE enjoys an international reputation. Its capability and experience in High Resolution instrumentation is recognised by the most customers. Coming after the SPOT program, it was decided to go ahead with the PLEIADES HR program. PLEIADES HR is the optical high resolution component of a larger optical and radar multi-sensors system : ORFEO, which is developed in cooperation between France and Italy for dual Civilian and Defense use. ALCATEL SPACE has been entrusted by CNES with the development of the high resolution camera of the Earth observation satellites PLEIADES HR. The first optical satellite of the PLEIADES HR constellation will be launched in mid-2008, the second will follow in 2009. To minimize the development costs, a mini satellite approach has been selected, leading to a compact concept for the camera design. The paper describes the design and performance budgets of this novel high resolution and large field of view optical instrument with emphasis on the technological features. This new generation of camera represents a breakthrough in comparison with the previous SPOT cameras owing to a significant step in on-ground resolution, which approaches the capabilities of aerial photography. Recent advances in detector technology, optical fabrication and electronics make it possible for the PLEIADES HR camera to achieve their image quality performance goals while staying within weight and size restrictions normally considered suitable only for much lower performance systems. This camera design delivers superior performance using an innovative low power, low mass, scalable architecture, which provides a versatile approach for a variety of imaging requirements and allows for a wide number of possibilities of accommodation with a mini-satellite class platform.
The spatial resolution of a rotating gamma camera tomographic facility.
Webb, S; Flower, M A; Ott, R J; Leach, M O; Inamdar, R
1983-12-01
An important feature determining the spatial resolution in transverse sections reconstructed by convolution and back-projection is the frequency filter corresponding to the convolution kernel. Equations have been derived giving the theoretical spatial resolution, for a perfect detector and noise-free data, using four filter functions. Experiments have shown that physical constraints will always limit the resolution that can be achieved with a given system. The experiments indicate that the region of the frequency spectrum between KN/2 and KN where KN is the Nyquist frequency does not contribute significantly to resolution. In order to investigate the physical effect of these filter functions, the spatial resolution of reconstructed images obtained with a GE 400T rotating gamma camera has been measured. The results obtained serve as an aid to choosing appropriate reconstruction filters for use with a rotating gamma camera system.
Sanchez-Bridge, Belén; Renouf, Mathieu; Sauser, Julien; Beaumont, Maurice; Actis-Goretta, Lucas
2016-05-01
Understanding the bioavailability and metabolism of coffee compounds will contribute to identify the unknown biological mechanism(s) linked to their beneficial effects. The influence of the roasting process on the metabolism of coffee chlorogenic acids in humans was evaluated. In a randomized, double-blind, crossover study, 12 healthy volunteers consumed four instant coffees namely, high roasted coffee (HRC), low roasted coffee (LRC), unroasted coffee (URC), and in vitro hydrolyzed unroasted coffee (HURC). The sum of areas under the curve (AUC) ranged from 8.65-17.6 to 30.9-126 µM/h (P < 0.05) for HRC, LRC, URC, and HURC, respectively. The AUC of HRC, LRC, and URC was correlated with the initial level of phenolic acids in the coffee drinks. Despite different absorption rates, the extent of conjugation was comparable between HRC, LRC, and URC coffees but different for HURC. The most abundant circulating metabolites during the first 5 H were dihydroferulic acid (DHFA), caffeic acid-3'-O-sulfate (CA3S) and isoferulic-3'-O-glucuronide (iFA3G). DHFA and 5-4-dihydro-m-coumaric acid (mDHCoA) were the main metabolites in the period of 5-24 H. The phenolic compounds after consumption of HURC were most rapidly absorbed (Tmax 1 H) compared with the other coffees (Tmax between 9 and 11 H). Using coffees with different degrees of roasting we highlighted that in spite of different absorption rates the extent of conjugation of phenolic acids was comparable. In addition, by using a hydrolyzed unroasted coffee we demonstrated an increased absorption of phenolic acids in the small intestine. © 2016 BioFactors, 42(3):259-267, 2016. © 2016 International Union of Biochemistry and Molecular Biology.
Camera system resolution and its influence on digital image correlation
Reu, Phillip L.; Sweatt, William; Miller, Timothy; ...
2014-09-21
Digital image correlation (DIC) uses images from a camera and lens system to make quantitative measurements of the shape, displacement, and strain of test objects. This increasingly popular method has had little research on the influence of the imaging system resolution on the DIC results. This paper investigates the entire imaging system and studies how both the camera and lens resolution influence the DIC results as a function of the system Modulation Transfer Function (MTF). It will show that when making spatial resolution decisions (including speckle size) the resolution limiting component should be considered. A consequence of the loss ofmore » spatial resolution is that the DIC uncertainties will be increased. This is demonstrated using both synthetic and experimental images with varying resolution. The loss of image resolution and DIC accuracy can be compensated for by increasing the subset size, or better, by increasing the speckle size. The speckle-size and spatial resolution are now a function of the lens resolution rather than the more typical assumption of the pixel size. The study will demonstrate the tradeoffs associated with limited lens resolution.« less
Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jianchao; Ding, Yonghua, E-mail: yhding@mail.hust.edu.cn; Zhang, Xiaoqing
2014-11-15
A new soft X-ray diagnostic system has been designed on the Joint Texas Experimental Tokamak (J-TEXT) aiming to observe and survey the magnetohydrodynamic (MHD) activities. The system consists of five cameras located at the same toroidal position. Each camera has 16 photodiode elements. Three imaging cameras view the internal plasma region (r/a < 0.7) with a spatial resolution about 2 cm. By tomographic method, heat transport outside from the 1/1 mode X-point during the sawtooth collapse is found. The other two cameras with a higher spatial resolution 1 cm are designed for monitoring local MHD activities respectively in plasma coremore » and boundary.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birch, Gabriel Carisle; Griffin, John Clark
2015-01-01
The horizontal television lines (HTVL) metric has been the primary quantity used by division 6000 related to camera resolution for high consequence security systems. This document shows HTVL measurements are fundamen- tally insufficient as a metric to determine camera resolution, and propose a quantitative, standards based methodology by measuring the camera system modulation transfer function (MTF), the most common and accepted metric of res- olution in the optical science community. Because HTVL calculations are easily misinterpreted or poorly defined, we present several scenarios in which HTVL is frequently reported, and discuss their problems. The MTF metric is discussed, and scenariosmore » are presented with calculations showing the application of such a metric.« less
Integrated ExoMars PanCam, Raman, and close-up imaging field tests on AMASE 2009
NASA Astrophysics Data System (ADS)
Foss Amundsen, Hans Erik; Westall, Frances; Steele, Andrew; Vago, Jorge; Schmitz, Nicole; Bauer, Arnold; Cousins, Claire; Rull, Fernando; Sansano, Antonio; Midtkandal, Ivar
2010-05-01
Arctic Mars Analog Svalbard Expedition (AMASE) uses Mars analog field sites on the Arctic islands of Svalbard (Norway) for research within astrobiology and for testing of payload instruments onboard Mars missions Mars Science Laboratory, ExoMars and Mars Sample Return. AMASE 2009 marked the seventh consecutive year of field testing. Instrument shakedowns were arranged to mimic rover operations on Mars and included the panoramic camera (PanCam), mineral- and organic chemistry sensors (Raman-LIBS) and ground penetrating radar (Wisdom) onboard ExoMars together with CheMin and SAM instruments onboard MSL and testing of sampling and caching protocols using JPĹs Fido rover. Test sites included volcanic rocks within the Bockfjord Volcanic Complex (BVC) with carbonate deposits identical to those in ALH84001 and Carboniferous sandstones and paleosols at Ismåsestranda. In view of the 2018 ExoMars mission, field models of the PanCam and Raman instruments, as well as an Olympus E410 camera having similar technical specifications to the ExoMars Close-Up Imager (CLUPI) were used in an integrated exercise to characterise the geology and habitability of the different field sites. The BVC locality consisted of volcanclastic sediments deposited on the flanks of the 1 Ma old Sverrefjell volcano. This volcano is constructed of primitive alkaline basalt with abundant mantle xenoliths. The sediments were a mixture of hyaloclastite, ash, volcanic bombs, lava detritus, and xenoliths (peridotites, granulites) deposited in a roughly laminated fashion on the slopes of the volcano. Late stage carbonate deposits were also present. The Ismåsestranda locality consisted of fine-grained sandstone deposited in a littoral environment. The sandstones were characterised by a variety of sedimentary structures reflecting a marginal marine depositional environment. They were highly variegated in colour due to diagenetic remobilisation of trace elements. PanCam made general context observations using the stereo Wide Angle Camera for taking images at 12 VIS-NIR wavelengths. More detailed images were made with the narrow angle colour High Resolution Channel of PanCam (PanCam HRC). These images were complimented by colour images made at 50-7 cm distance from the rock targets by the CLUPI-simulator camera. Compositional information was provided by the Raman spectrometer.The images and analyses obtained from the instruments permitted preliminary characterisation of the geological context at the two test sites. However, full characterisation of the rocks using more than one site is necessary to correctly interpret the nature of the rocks and their environment of formation, especially in the case of the Ismåsestranda sediments. Joint testing of ExoMars, MSL and MSR instruments on AMASE provides a unique opportunity to highgrade instrument selection for future Mars missions and to foster collaboration between ESA and NASA teams towards the tandem launch of ExoMars and MAX-C in 2018.
Hydrogen recombiner catalyst test supporting data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton, M.D.
1995-01-19
This is a data package supporting the Hydrogen Recombiner Catalyst Performance and Carbon Monoxide Sorption Capacity Test Report, WHC-SD-WM-TRP-211, Rev 0. This report contains 10 appendices which consist of the following: Mass spectrometer analysis reports: HRC samples 93-001 through 93-157; Gas spectrometry analysis reports: HRC samples 93-141 through 93-658; Mass spectrometer procedure PNL-MA-299 ALO-284; Alternate analytical method for ammonia and water vapor; Sample log sheets; Job Safety analysis; Certificate of mixture analysis for feed gases; Flow controller calibration check; Westinghouse Standards Laboratory report on Bois flow calibrator; and Sorption capacity test data, tables, and graphs.
The Chandra Source Catalog: X-ray Aperture Photometry
NASA Astrophysics Data System (ADS)
Kashyap, Vinay; Primini, F. A.; Glotfelty, K. J.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, I. N.; Evans, J. D.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Grier, J. D.; Hain, R.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McCollough, M. L.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Rots, A. H.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; Van Stone, D. W.; Winkelman, S. L.; Zografou, P.
2009-01-01
The Chandra Source Catalog represents a reanalysis of the entire ACIS and HRC imaging observations over the 9-year Chandra mission. Source detection is carried out on a uniform basis, using the CIAO tool wavdetect, and source fluxes are estimated post-facto using a Bayesian method that accounts for background, spatial resolution effects, and contamination from nearby sources. We use gamma-function prior distributions, which could be either non-informative, or in case there exist previous observations of the same source, strongly informative. The resulting posterior probability density functions allow us to report the flux and a robust credible range on it. We also determine limiting sensitivities at arbitrary locations in the field using the same formulation. This work was supported by CXC NASA contracts NAS8-39073 (VK) and NAS8-03060 (CSC).
Image quality assessment for selfies with and without super resolution
NASA Astrophysics Data System (ADS)
Kubota, Aya; Gohshi, Seiichi
2018-04-01
With the advent of cellphone cameras, in particular, on smartphones, many people now take photos of themselves alone and with others in the frame; such photos are popularly known as "selfies". Most smartphones are equipped with two cameras: the front-facing and rear cameras. The camera located on the back of the smartphone is referred to as the "out-camera," whereas the one located on the front of the smartphone is called the "in-camera." In-cameras are mainly used for selfies. Some smartphones feature high-resolution cameras. However, the original image quality cannot be obtained because smartphone cameras often have low-performance lenses. Super resolution (SR) is one of the recent technological advancements that has increased image resolution. We developed a new SR technology that can be processed on smartphones. Smartphones with new SR technology are currently available in the market have already registered sales. However, the effective use of new SR technology has not yet been verified. Comparing the image quality with and without SR on smartphone display is necessary to confirm the usefulness of this new technology. Methods that are based on objective and subjective assessments are required to quantitatively measure image quality. It is known that the typical object assessment value, such as Peak Signal to Noise Ratio (PSNR), does not go together with how we feel when we assess image/video. When digital broadcast started, the standard was determined using subjective assessment. Although subjective assessment usually comes at high cost because of personnel expenses for observers, the results are highly reproducible when they are conducted under right conditions and statistical analysis. In this study, the subjective assessment results for selfie images are reported.
A detailed comparison of single-camera light-field PIV and tomographic PIV
NASA Astrophysics Data System (ADS)
Shi, Shengxian; Ding, Junfei; Atkinson, Callum; Soria, Julio; New, T. H.
2018-03-01
This paper conducts a comprehensive study between the single-camera light-field particle image velocimetry (LF-PIV) and the multi-camera tomographic particle image velocimetry (Tomo-PIV). Simulation studies were first performed using synthetic light-field and tomographic particle images, which extensively examine the difference between these two techniques by varying key parameters such as pixel to microlens ratio (PMR), light-field camera Tomo-camera pixel ratio (LTPR), particle seeding density and tomographic camera number. Simulation results indicate that the single LF-PIV can achieve accuracy consistent with that of multi-camera Tomo-PIV, but requires the use of overall greater number of pixels. Experimental studies were then conducted by simultaneously measuring low-speed jet flow with single-camera LF-PIV and four-camera Tomo-PIV systems. Experiments confirm that given a sufficiently high pixel resolution, a single-camera LF-PIV system can indeed deliver volumetric velocity field measurements for an equivalent field of view with a spatial resolution commensurate with those of multi-camera Tomo-PIV system, enabling accurate 3D measurements in applications where optical access is limited.
NASA Technical Reports Server (NTRS)
Tarbell, Theodore D.
1993-01-01
Technical studies of the feasibility of balloon flights of the former Spacelab instrument, the Solar Optical Universal Polarimeter, with a modern charge-coupled device (CCD) camera, to study the structure and evolution of solar active regions at high resolution, are reviewed. In particular, different CCD cameras were used at ground-based solar observatories with the SOUP filter, to evaluate their performance and collect high resolution images. High resolution movies of the photosphere and chromosphere were successfully obtained using four different CCD cameras. Some of this data was collected in coordinated observations with the Yohkoh satellite during May-July, 1992, and they are being analyzed scientifically along with simultaneous X-ray observations.
Fast and compact internal scanning CMOS-based hyperspectral camera: the Snapscan
NASA Astrophysics Data System (ADS)
Pichette, Julien; Charle, Wouter; Lambrechts, Andy
2017-02-01
Imec has developed a process for the monolithic integration of optical filters on top of CMOS image sensors, leading to compact, cost-efficient and faster hyperspectral cameras. Linescan cameras are typically used in remote sensing or for conveyor belt applications. Translation of the target is not always possible for large objects or in many medical applications. Therefore, we introduce a novel camera, the Snapscan (patent pending), exploiting internal movement of a linescan sensor enabling fast and convenient acquisition of high-resolution hyperspectral cubes (up to 2048x3652x150 in spectral range 475-925 nm). The Snapscan combines the spectral and spatial resolutions of a linescan system with the convenience of a snapshot camera.
NASA Astrophysics Data System (ADS)
Neukum, Gerhard; Jaumann, Ralf; Scholten, Frank; Gwinner, Klaus
2017-11-01
At the Institute of Space Sensor Technology and Planetary Exploration of the German Aerospace Center (DLR) the High Resolution Stereo Camera (HRSC) has been designed for international missions to planet Mars. For more than three years an airborne version of this camera, the HRSC-A, has been successfully applied in many flight campaigns and in a variety of different applications. It combines 3D-capabilities and high resolution with multispectral data acquisition. Variable resolutions depending on the camera control settings can be generated. A high-end GPS/INS system in combination with the multi-angle image information yields precise and high-frequent orientation data for the acquired image lines. In order to handle these data a completely automated photogrammetric processing system has been developed, and allows to generate multispectral 3D-image products for large areas and with accuracies for planimetry and height in the decimeter range. This accuracy has been confirmed by detailed investigations.
SPARTAN Near-IR Camera SPARTAN Cookbook Ohio State Infrared Imager/Spectrograph (OSIRIS) - NO LONGER Instrumentation at SOAR»SPARTAN Near-IR Camera SPARTAN Near-IR Camera System Overview The Spartan Infrared Camera is a high spatial resolution near-IR imager. Spartan has a focal plane conisisting of four "
NASA Astrophysics Data System (ADS)
Chi, Yuxi; Yu, Liping; Pan, Bing
2018-05-01
A low-cost, portable, robust and high-resolution single-camera stereo-digital image correlation (stereo-DIC) system for accurate surface three-dimensional (3D) shape and deformation measurements is described. This system adopts a single consumer-grade high-resolution digital Single Lens Reflex (SLR) camera and a four-mirror adaptor, rather than two synchronized industrial digital cameras, for stereo image acquisition. In addition, monochromatic blue light illumination and coupled bandpass filter imaging are integrated to ensure the robustness of the system against ambient light variations. In contrast to conventional binocular stereo-DIC systems, the developed pseudo-stereo-DIC system offers the advantages of low cost, portability, robustness against ambient light variations, and high resolution. The accuracy and precision of the developed single SLR camera-based stereo-DIC system were validated by measuring the 3D shape of a stationary sphere along with in-plane and out-of-plane displacements of a translated planar plate. Application of the established system to thermal deformation measurement of an alumina ceramic plate and a stainless-steel plate subjected to radiation heating was also demonstrated.
Mars Global Coverage by Context Camera on MRO
2017-03-29
In early 2017, after more than a decade of observing Mars, the Context Camera (CTX) on NASA's Mars Reconnaissance Orbiter (MRO) surpassed 99 percent coverage of the entire planet. This mosaic shows that global coverage. No other camera has ever imaged so much of Mars in such high resolution. The mosaic offers a resolution that enables zooming in for more detail of any region of Mars. It is still far from the full resolution of individual CTX observations, which can reveal the shapes of features smaller than the size of a tennis court. As of March 2017, the Context Camera has taken about 90,000 images since the spacecraft began examining Mars from orbit in late 2006. In addition to covering 99.1 percent of the surface of Mars at least once, this camera has observed more than 60 percent of Mars more than once, checking for changes over time and providing stereo pairs for 3-D modeling of the surface. http://photojournal.jpl.nasa.gov/catalog/PIA21488
High-resolution ophthalmic imaging system
Olivier, Scot S.; Carrano, Carmen J.
2007-12-04
A system for providing an improved resolution retina image comprising an imaging camera for capturing a retina image and a computer system operatively connected to the imaging camera, the computer producing short exposures of the retina image and providing speckle processing of the short exposures to provide the improved resolution retina image. The system comprises the steps of capturing a retina image, producing short exposures of the retina image, and speckle processing the short exposures of the retina image to provide the improved resolution retina image.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram
Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.
Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram; ...
2017-11-07
Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.
Development of a Compton camera for safeguards applications in a pyroprocessing facility
NASA Astrophysics Data System (ADS)
Park, Jin Hyung; Kim, Young Su; Kim, Chan Hyeong; Seo, Hee; Park, Se-Hwan; Kim, Ho-Dong
2014-11-01
The Compton camera has a potential to be used for localizing nuclear materials in a large pyroprocessing facility due to its unique Compton kinematics-based electronic collimation method. Our R&D group, KAERI, and Hanyang University have made an effort to develop a scintillation-detector-based large-area Compton camera for safeguards applications. In the present study, a series of Monte Carlo simulations was performed with Geant4 in order to examine the effect of the detector parameters and the feasibility of using a Compton camera to obtain an image of the nuclear material distribution. Based on the simulation study, experimental studies were performed to assess the possibility of Compton imaging in accordance with the type of the crystal. Two different types of Compton cameras were fabricated and tested with a pixelated type of LYSO (Ce) and a monolithic type of NaI(Tl). The conclusions of this study as a design rule for a large-area Compton camera can be summarized as follows: 1) The energy resolution, rather than position resolution, of the component detector was the limiting factor for the imaging resolution, 2) the Compton imaging system needs to be placed as close as possible to the source location, and 3) both pixelated and monolithic types of crystals can be utilized; however, the monolithic types, require a stochastic-method-based position-estimating algorithm for improving the position resolution.
Autonomous Surface Sample Acquisition for Planetary and Lunar Exploration
NASA Astrophysics Data System (ADS)
Barnes, D. P.
2007-08-01
Surface science sample acquisition is a critical activity within any planetary and lunar exploration mission, and our research is focused upon the design, implementation, experimentation and demonstration of an onboard autonomous surface sample acquisition capability for a rover equipped with a robotic arm upon which are mounted appropriate science instruments. Images captured by a rover stereo camera system can be processed using shape from stereo methods and a digital elevation model (DEM) generated. We have developed a terrain feature identification algorithm that can determine autonomously from DEM data suitable regions for instrument placement and/or surface sample acquisition. Once identified, surface normal data can be generated autonomously which are then used to calculate an arm trajectory for instrument placement and sample acquisition. Once an instrument placement and sample acquisition trajectory has been calculated, a collision detection algorithm is required to ensure the safe operation of the arm during sample acquisition.We have developed a novel adaptive 'bounding spheres' approach to this problem. Once potential science targets have been identified, and these are within the reach of the arm and will not cause any undesired collision, then the 'cost' of executing the sample acquisition activity is required. Such information which includes power expenditure and duration can be used to select the 'best' target from a set of potential targets. We have developed a science sample acquisition resource requirements calculation that utilises differential inverse kinematics methods to yield a high fidelity result, thus improving upon simple 1st order approximations. To test our algorithms a new Planetary Analogue Terrain (PAT) Laboratory has been created that has a terrain region composed of Mars Soil Simulant-D from DLR Germany, and rocks that have been fully characterised in the laboratory. These have been donated by the UK Planetary Analogue Field Study network, and constitute the science targets for our autonomous sample acquisition work. Our PAT Lab. terrain has been designed to support our new rover chassis which is based upon the ExoMars rover Concept-E mechanics which were investigated during the ESA ExoMars Phase A study. The rover has 6 wheel drives, 6 wheels steering, and a 6 wheel walking capability. Mounted on the rover chassis is the UWA robotic arm and mast. We have designed and built a PanCam system complete with a computer controlled pan and tilt mechanism. The UWA PanCam is based upon the ExoMars PanCam (Phase A study) and hence supports two Wide Angle Cameras (WAC - 64 degree FOV), and a High Resolution Camera (HRC - 5 degree FOV). WAC separation is 500 mm. Software has been developed to capture images which form the data input into our on-board autonomous surface sample acquisition algorithms.
Time-of-Flight Microwave Camera.
Charvat, Gregory; Temme, Andrew; Feigin, Micha; Raskar, Ramesh
2015-10-05
Microwaves can penetrate many obstructions that are opaque at visible wavelengths, however microwave imaging is challenging due to resolution limits associated with relatively small apertures and unrecoverable "stealth" regions due to the specularity of most objects at microwave frequencies. We demonstrate a multispectral time-of-flight microwave imaging system which overcomes these challenges with a large passive aperture to improve lateral resolution, multiple illumination points with a data fusion method to reduce stealth regions, and a frequency modulated continuous wave (FMCW) receiver to achieve depth resolution. The camera captures images with a resolution of 1.5 degrees, multispectral images across the X frequency band (8 GHz-12 GHz), and a time resolution of 200 ps (6 cm optical path in free space). Images are taken of objects in free space as well as behind drywall and plywood. This architecture allows "camera-like" behavior from a microwave imaging system and is practical for imaging everyday objects in the microwave spectrum.
NASA Technical Reports Server (NTRS)
Miller, Chris; Mulavara, Ajitkumar; Bloomberg, Jacob
2001-01-01
To confidently report any data collected from a video-based motion capture system, its functional characteristics must be determined, namely accuracy, repeatability and resolution. Many researchers have examined these characteristics with motion capture systems, but they used only two cameras, positioned 90 degrees to each other. Everaert used 4 cameras, but all were aligned along major axes (two in x, one in y and z). Richards compared the characteristics of different commercially available systems set-up in practical configurations, but all cameras viewed a single calibration volume. The purpose of this study was to determine the accuracy, repeatability and resolution of a 6-camera Motion Analysis system in a split-volume configuration using a quasistatic methodology.
Commissioning and Characterization of a Dedicated High-Resolution Breast PET Camera
2014-02-01
aim to achieve 1 mm3 resolution using a unique detector design that is able to measure annihilation radiation coming from the PET tracer in 3...undergoing a regular staging PET /CT. We will image with the novel two-panel system after the standard PET /CT scan , in order not to interfere with the...Resolution Breast PET Camera PRINCIPAL INVESTIGATOR: Arne Vandenbroucke, Ph.D. CONTRACTING ORGANIZATION: Stanford University
Traffic Sign Recognition with Invariance to Lighting in Dual-Focal Active Camera System
NASA Astrophysics Data System (ADS)
Gu, Yanlei; Panahpour Tehrani, Mehrdad; Yendo, Tomohiro; Fujii, Toshiaki; Tanimoto, Masayuki
In this paper, we present an automatic vision-based traffic sign recognition system, which can detect and classify traffic signs at long distance under different lighting conditions. To realize this purpose, the traffic sign recognition is developed in an originally proposed dual-focal active camera system. In this system, a telephoto camera is equipped as an assistant of a wide angle camera. The telephoto camera can capture a high accuracy image for an object of interest in the view field of the wide angle camera. The image from the telephoto camera provides enough information for recognition when the accuracy of traffic sign is low from the wide angle camera. In the proposed system, the traffic sign detection and classification are processed separately for different images from the wide angle camera and telephoto camera. Besides, in order to detect traffic sign from complex background in different lighting conditions, we propose a type of color transformation which is invariant to light changing. This color transformation is conducted to highlight the pattern of traffic signs by reducing the complexity of background. Based on the color transformation, a multi-resolution detector with cascade mode is trained and used to locate traffic signs at low resolution in the image from the wide angle camera. After detection, the system actively captures a high accuracy image of each detected traffic sign by controlling the direction and exposure time of the telephoto camera based on the information from the wide angle camera. Moreover, in classification, a hierarchical classifier is constructed and used to recognize the detected traffic signs in the high accuracy image from the telephoto camera. Finally, based on the proposed system, a set of experiments in the domain of traffic sign recognition is presented. The experimental results demonstrate that the proposed system can effectively recognize traffic signs at low resolution in different lighting conditions.
Low-cost camera modifications and methodologies for very-high-resolution digital images
USDA-ARS?s Scientific Manuscript database
Aerial color and color-infrared photography are usually acquired at high altitude so the ground resolution of the photographs is < 1 m. Moreover, current color-infrared cameras and manned aircraft flight time are expensive, so the objective is the development of alternative methods for obtaining ve...
Solid state replacement of rotating mirror cameras
NASA Astrophysics Data System (ADS)
Frank, Alan M.; Bartolick, Joseph M.
2007-01-01
Rotating mirror cameras have been the mainstay of mega-frame per second imaging for decades. There is still no electronic camera that can match a film based rotary mirror camera for the combination of frame count, speed, resolution and dynamic range. The rotary mirror cameras are predominantly used in the range of 0.1 to 100 micro-seconds per frame, for 25 to more than a hundred frames. Electron tube gated cameras dominate the sub microsecond regime but are frame count limited. Video cameras are pushing into the microsecond regime but are resolution limited by the high data rates. An all solid state architecture, dubbed 'In-situ Storage Image Sensor' or 'ISIS', by Prof. Goji Etoh has made its first appearance into the market and its evaluation is discussed. Recent work at Lawrence Livermore National Laboratory has concentrated both on evaluation of the presently available technologies and exploring the capabilities of the ISIS architecture. It is clear though there is presently no single chip camera that can simultaneously match the rotary mirror cameras, the ISIS architecture has the potential to approach their performance.
Surveillance of a 2D Plane Area with 3D Deployed Cameras
Fu, Yi-Ge; Zhou, Jie; Deng, Lei
2014-01-01
As the use of camera networks has expanded, camera placement to satisfy some quality assurance parameters (such as a good coverage ratio, an acceptable resolution constraints, an acceptable cost as low as possible, etc.) has become an important problem. The discrete camera deployment problem is NP-hard and many heuristic methods have been proposed to solve it, most of which make very simple assumptions. In this paper, we propose a probability inspired binary Particle Swarm Optimization (PI-BPSO) algorithm to solve a homogeneous camera network placement problem. We model the problem under some more realistic assumptions: (1) deploy the cameras in the 3D space while the surveillance area is restricted to a 2D ground plane; (2) deploy the minimal number of cameras to get a maximum visual coverage under more constraints, such as field of view (FOV) of the cameras and the minimum resolution constraints. We can simultaneously optimize the number and the configuration of the cameras through the introduction of a regulation item in the cost function. The simulation results showed the effectiveness of the proposed PI-BPSO algorithm. PMID:24469353
X-ray selected stars in HRC and BHRC catalogues
NASA Astrophysics Data System (ADS)
Mickaelian, A. M.; Paronyan, G. M.
2014-12-01
A joint HRC/BHRC Catalogue has been created based on merging of Hamburg ROSAT Catalogue (HRC) and Byurakan Hamburg ROSAT Catalogue (BHRC). Both have been made by optical identifications of X-ray sources based on low-dispersion spectra of the Hamburg Quasar Survey (HQS) using ROSAT Catalogues. As a result, the largest sample of 8132 (5341+2791) optically identified X-ray sources was created having count rate (CR) of photons ≤ 0.04 ct/s in the area with galactic latitudes |b|≤ 20° and declinations d≤ 0°.There are 4253 AGN, 492 galaxies, 1800 stars and 1587 unknown objects in the sample. All stars have been found in GSC 2.3.2, as well as most of them are in GALEX, USNO-B1.0, 2MASS and WISE catalogues. In addition, 1429 are in SDSS DR9 and 204 have SDSS spectra. For these stars we have carried out spectral classification and along with the bright stars, many new cataclysmic variables (CV), white dwarfs (WD) and late-type stars (K-M and C) have been revealed. For all stars, statistical studies of their multiwavelength properties have been made. An attempt to find a connection between the radiation fluxes in different bands for different types of sources, and identify their characteristics was made as well.
Calibration of Action Cameras for Photogrammetric Purposes
Balletti, Caterina; Guerra, Francesco; Tsioukas, Vassilios; Vernier, Paolo
2014-01-01
The use of action cameras for photogrammetry purposes is not widespread due to the fact that until recently the images provided by the sensors, using either still or video capture mode, were not big enough to perform and provide the appropriate analysis with the necessary photogrammetric accuracy. However, several manufacturers have recently produced and released new lightweight devices which are: (a) easy to handle, (b) capable of performing under extreme conditions and more importantly (c) able to provide both still images and video sequences of high resolution. In order to be able to use the sensor of action cameras we must apply a careful and reliable self-calibration prior to the use of any photogrammetric procedure, a relatively difficult scenario because of the short focal length of the camera and its wide angle lens that is used to obtain the maximum possible resolution of images. Special software, using functions of the OpenCV library, has been created to perform both the calibration and the production of undistorted scenes for each one of the still and video image capturing mode of a novel action camera, the GoPro Hero 3 camera that can provide still images up to 12 Mp and video up 8 Mp resolution. PMID:25237898
Calibration of action cameras for photogrammetric purposes.
Balletti, Caterina; Guerra, Francesco; Tsioukas, Vassilios; Vernier, Paolo
2014-09-18
The use of action cameras for photogrammetry purposes is not widespread due to the fact that until recently the images provided by the sensors, using either still or video capture mode, were not big enough to perform and provide the appropriate analysis with the necessary photogrammetric accuracy. However, several manufacturers have recently produced and released new lightweight devices which are: (a) easy to handle, (b) capable of performing under extreme conditions and more importantly (c) able to provide both still images and video sequences of high resolution. In order to be able to use the sensor of action cameras we must apply a careful and reliable self-calibration prior to the use of any photogrammetric procedure, a relatively difficult scenario because of the short focal length of the camera and its wide angle lens that is used to obtain the maximum possible resolution of images. Special software, using functions of the OpenCV library, has been created to perform both the calibration and the production of undistorted scenes for each one of the still and video image capturing mode of a novel action camera, the GoPro Hero 3 camera that can provide still images up to 12 Mp and video up 8 Mp resolution.
Development of an all-in-one gamma camera/CCD system for safeguard verification
NASA Astrophysics Data System (ADS)
Kim, Hyun-Il; An, Su Jung; Chung, Yong Hyun; Kwak, Sung-Woo
2014-12-01
For the purpose of monitoring and verifying efforts at safeguarding radioactive materials in various fields, a new all-in-one gamma camera/charged coupled device (CCD) system was developed. This combined system consists of a gamma camera, which gathers energy and position information on gamma-ray sources, and a CCD camera, which identifies the specific location in a monitored area. Therefore, 2-D image information and quantitative information regarding gamma-ray sources can be obtained using fused images. A gamma camera consists of a diverging collimator, a 22 × 22 array CsI(Na) pixelated scintillation crystal with a pixel size of 2 × 2 × 6 mm3 and Hamamatsu H8500 position-sensitive photomultiplier tube (PSPMT). The Basler scA640-70gc CCD camera, which delivers 70 frames per second at video graphics array (VGA) resolution, was employed. Performance testing was performed using a Co-57 point source 30 cm from the detector. The measured spatial resolution and sensitivity were 4.77 mm full width at half maximum (FWHM) and 7.78 cps/MBq, respectively. The energy resolution was 18% at 122 keV. These results demonstrate that the combined system has considerable potential for radiation monitoring.
Advantages of computer cameras over video cameras/frame grabbers for high-speed vision applications
NASA Astrophysics Data System (ADS)
Olson, Gaylord G.; Walker, Jo N.
1997-09-01
Cameras designed to work specifically with computers can have certain advantages in comparison to the use of cameras loosely defined as 'video' cameras. In recent years the camera type distinctions have become somewhat blurred, with a great presence of 'digital cameras' aimed more at the home markets. This latter category is not considered here. The term 'computer camera' herein is intended to mean one which has low level computer (and software) control of the CCD clocking. These can often be used to satisfy some of the more demanding machine vision tasks, and in some cases with a higher rate of measurements than video cameras. Several of these specific applications are described here, including some which use recently designed CCDs which offer good combinations of parameters such as noise, speed, and resolution. Among the considerations for the choice of camera type in any given application would be such effects as 'pixel jitter,' and 'anti-aliasing.' Some of these effects may only be relevant if there is a mismatch between the number of pixels per line in the camera CCD and the number of analog to digital (A/D) sampling points along a video scan line. For the computer camera case these numbers are guaranteed to match, which alleviates some measurement inaccuracies and leads to higher effective resolution.
A new omni-directional multi-camera system for high resolution surveillance
NASA Astrophysics Data System (ADS)
Cogal, Omer; Akin, Abdulkadir; Seyid, Kerem; Popovic, Vladan; Schmid, Alexandre; Ott, Beat; Wellig, Peter; Leblebici, Yusuf
2014-05-01
Omni-directional high resolution surveillance has a wide application range in defense and security fields. Early systems used for this purpose are based on parabolic mirror or fisheye lens where distortion due to the nature of the optical elements cannot be avoided. Moreover, in such systems, the image resolution is limited to a single image sensor's image resolution. Recently, the Panoptic camera approach that mimics the eyes of flying insects using multiple imagers has been presented. This approach features a novel solution for constructing a spherically arranged wide FOV plenoptic imaging system where the omni-directional image quality is limited by low-end sensors. In this paper, an overview of current Panoptic camera designs is provided. New results for a very-high resolution visible spectrum imaging and recording system inspired from the Panoptic approach are presented. The GigaEye-1 system, with 44 single cameras and 22 FPGAs, is capable of recording omni-directional video in a 360°×100° FOV at 9.5 fps with a resolution over (17,700×4,650) pixels (82.3MP). Real-time video capturing capability is also verified at 30 fps for a resolution over (9,000×2,400) pixels (21.6MP). The next generation system with significantly higher resolution and real-time processing capacity, called GigaEye-2, is currently under development. The important capacity of GigaEye-1 opens the door to various post-processing techniques in surveillance domain such as large perimeter object tracking, very-high resolution depth map estimation and high dynamicrange imaging which are beyond standard stitching and panorama generation methods.
Gyrocopter-Based Remote Sensing Platform
NASA Astrophysics Data System (ADS)
Weber, I.; Jenal, A.; Kneer, C.; Bongartz, J.
2015-04-01
In this paper the development of a lightweight and highly modularized airborne sensor platform for remote sensing applications utilizing a gyrocopter as a carrier platform is described. The current sensor configuration consists of a high resolution DSLR camera for VIS-RGB recordings. As a second sensor modality, a snapshot hyperspectral camera was integrated in the aircraft. Moreover a custom-developed thermal imaging system composed of a VIS-PAN camera and a LWIR-camera is used for aerial recordings in the thermal infrared range. Furthermore another custom-developed highly flexible imaging system for high resolution multispectral image acquisition with up to six spectral bands in the VIS-NIR range is presented. The performance of the overall system was tested during several flights with all sensor modalities and the precalculated demands with respect to spatial resolution and reliability were validated. The collected data sets were georeferenced, georectified, orthorectified and then stitched to mosaics.
a Spatio-Spectral Camera for High Resolution Hyperspectral Imaging
NASA Astrophysics Data System (ADS)
Livens, S.; Pauly, K.; Baeck, P.; Blommaert, J.; Nuyts, D.; Zender, J.; Delauré, B.
2017-08-01
Imaging with a conventional frame camera from a moving remotely piloted aircraft system (RPAS) is by design very inefficient. Less than 1 % of the flying time is used for collecting light. This unused potential can be utilized by an innovative imaging concept, the spatio-spectral camera. The core of the camera is a frame sensor with a large number of hyperspectral filters arranged on the sensor in stepwise lines. It combines the advantages of frame cameras with those of pushbroom cameras. By acquiring images in rapid succession, such a camera can collect detailed hyperspectral information, while retaining the high spatial resolution offered by the sensor. We have developed two versions of a spatio-spectral camera and used them in a variety of conditions. In this paper, we present a summary of three missions with the in-house developed COSI prototype camera (600-900 nm) in the domains of precision agriculture (fungus infection monitoring in experimental wheat plots), horticulture (crop status monitoring to evaluate irrigation management in strawberry fields) and geology (meteorite detection on a grassland field). Additionally, we describe the characteristics of the 2nd generation, commercially available ButterflEYE camera offering extended spectral range (475-925 nm), and we discuss future work.
Ricciardi, Annamaria; Parente, Eugenio; Guidone, Angela; Ianniello, Rocco Gerardo; Zotta, Teresa; Abu Sayem, S M; Varcamonti, Mario
2012-07-02
Lactobacillus plantarum, Lactobacillus pentosus and Lactobacillus paraplantarum are three closely related species which are widespread in food and non-food environments, and are important as starter bacteria or probiotics. In order to evaluate the phenotypic diversity of stress tolerance in the L. plantarum group and the ability to mount an adaptive heat shock response, the survival of exponential and stationary phase and of heat adapted exponential phase cells of six L. plantarum subsp. plantarum, one L. plantarum subsp. argentoratensis, one L. pentosus and two L. paraplantarum strains selected in a previous work upon exposure to oxidative, heat, detergent, starvation and acid stresses was compared to that of the L. plantarum WCFS1 strain. Furthermore, to evaluate the genotypic diversity in stress response genes, ten genes (encoding for chaperones DnaK, GroES and GroEL, regulators CtsR, HrcA and CcpA, ATPases/proteases ClpL, ClpP, ClpX and protease FtsH) were amplified using primers derived from the WCFS1 genome sequence and submitted to restriction with one or two endonucleases. The results were compared by univariate and multivariate statistical methods. In addition, the amplicons for hrcA and ctsR were sequenced and compared by multiple sequence alignment and polymorphism analysis. Although there was evidence of a generalized stress response in the stationary phase, with increase of oxidative, heat, and, to a lesser extent, starvation stress tolerance, and for adaptive heat stress response, with increased tolerance to heat, acid and detergent, different growth phases and adaptation patterns were found. Principal component analysis showed that while heat, acid and detergent stresses respond similarly to growth phase and adaptation, tolerance to oxidative and starvation stresses implies completely unrelated mechanisms. A dendrogram obtained using the data from multilocus restriction typing (MLRT) of stress response genes clearly separated two groups of L. plantarum strains from the other species but there was no correlation between genotypic grouping and grouping obtained on the basis of the stress response pattern, nor with the phylograms obtained from hrcA and ctsR sequences. Differences in sequence in L. plantarum strains were mostly due to single nucleotide polymorphisms with a high frequency of synonymous nucleotide changes and, while hrcA was characterized by an excess of low frequency polymorphism, very low diversity was found in ctsR sequences. Sequence alignment of hrcA allowed a correct discrimination of the strains at the species level, thus confirming the relevance of stress response genes for taxonomy. Copyright © 2012 Elsevier B.V. All rights reserved.
Performance evaluation of a two detector camera for real-time video.
Lochocki, Benjamin; Gambín-Regadera, Adrián; Artal, Pablo
2016-12-20
Single pixel imaging can be the preferred method over traditional 2D-array imaging in spectral ranges where conventional cameras are not available. However, when it comes to real-time video imaging, single pixel imaging cannot compete with the framerates of conventional cameras, especially when high-resolution images are desired. Here we evaluate the performance of an imaging approach using two detectors simultaneously. First, we present theoretical results on how low SNR affects final image quality followed by experimentally determined results. Obtained video framerates were doubled compared to state of the art systems, resulting in a framerate from 22 Hz for a 32×32 resolution to 0.75 Hz for a 128×128 resolution image. Additionally, the two detector imaging technique enables the acquisition of images with a resolution of 256×256 in less than 3 s.
Spatial and Angular Resolution Enhancement of Light Fields Using Convolutional Neural Networks
NASA Astrophysics Data System (ADS)
Gul, M. Shahzeb Khan; Gunturk, Bahadir K.
2018-05-01
Light field imaging extends the traditional photography by capturing both spatial and angular distribution of light, which enables new capabilities, including post-capture refocusing, post-capture aperture control, and depth estimation from a single shot. Micro-lens array (MLA) based light field cameras offer a cost-effective approach to capture light field. A major drawback of MLA based light field cameras is low spatial resolution, which is due to the fact that a single image sensor is shared to capture both spatial and angular information. In this paper, we present a learning based light field enhancement approach. Both spatial and angular resolution of captured light field is enhanced using convolutional neural networks. The proposed method is tested with real light field data captured with a Lytro light field camera, clearly demonstrating spatial and angular resolution improvement.
Spatial and Angular Resolution Enhancement of Light Fields Using Convolutional Neural Networks.
Gul, M Shahzeb Khan; Gunturk, Bahadir K
2018-05-01
Light field imaging extends the traditional photography by capturing both spatial and angular distribution of light, which enables new capabilities, including post-capture refocusing, post-capture aperture control, and depth estimation from a single shot. Micro-lens array (MLA) based light field cameras offer a cost-effective approach to capture light field. A major drawback of MLA based light field cameras is low spatial resolution, which is due to the fact that a single image sensor is shared to capture both spatial and angular information. In this paper, we present a learning based light field enhancement approach. Both spatial and angular resolution of captured light field is enhanced using convolutional neural networks. The proposed method is tested with real light field data captured with a Lytro light field camera, clearly demonstrating spatial and angular resolution improvement.
Sub-picosecond streak camera measurements at LLNL: From IR to x-rays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuba, J; Shepherd, R; Booth, R
An ultra fast, sub-picosecond resolution streak camera has been recently developed at the LLNL. The camera is a versatile instrument with a wide operating wavelength range. The temporal resolution of up to 300 fs can be achieved, with routine operation at 500 fs. The streak camera has been operated in a wide wavelength range from IR to x-rays up to 2 keV. In this paper we briefly review the main design features that result in the unique properties of the streak camera and present its several scientific applications: (1) Streak camera characterization using a Michelson interferometer in visible range, (2)more » temporally resolved study of a transient x-ray laser at 14.7 nm, which enabled us to vary the x-ray laser pulse duration from {approx}2-6 ps by changing the pump laser parameters, and (3) an example of a time-resolved spectroscopy experiment with the streak camera.« less
Minimum Requirements for Taxicab Security Cameras.
Zeng, Shengke; Amandus, Harlan E; Amendola, Alfred A; Newbraugh, Bradley H; Cantis, Douglas M; Weaver, Darlene
2014-07-01
The homicide rate of taxicab-industry is 20 times greater than that of all workers. A NIOSH study showed that cities with taxicab-security cameras experienced significant reduction in taxicab driver homicides. Minimum technical requirements and a standard test protocol for taxicab-security cameras for effective taxicab-facial identification were determined. The study took more than 10,000 photographs of human-face charts in a simulated-taxicab with various photographic resolutions, dynamic ranges, lens-distortions, and motion-blurs in various light and cab-seat conditions. Thirteen volunteer photograph-evaluators evaluated these face photographs and voted for the minimum technical requirements for taxicab-security cameras. Five worst-case scenario photographic image quality thresholds were suggested: the resolution of XGA-format, highlight-dynamic-range of 1 EV, twilight-dynamic-range of 3.3 EV, lens-distortion of 30%, and shutter-speed of 1/30 second. These minimum requirements will help taxicab regulators and fleets to identify effective taxicab-security cameras, and help taxicab-security camera manufacturers to improve the camera facial identification capability.
NASA Astrophysics Data System (ADS)
Michaelis, Dirk; Schroeder, Andreas
2012-11-01
Tomographic PIV has triggered vivid activity, reflected in a large number of publications, covering both: development of the technique and a wide range of fluid dynamic experiments. Maturing of tomo PIV allows the application in medium to large scale wind tunnels. Limiting factor for wind tunnel application is the small size of the measurement volume, being typically about of 50 × 50 × 15 mm3. Aim of this study is the optimization towards large measurement volumes and high spatial resolution performing cylinder wake measurements in a 1 meter wind tunnel. Main limiting factors for the volume size are the laser power and the camera sensitivity. So, a high power laser with 800 mJ per pulse is used together with low noise sCMOS cameras, mounted in forward scattering direction to gain intensity due to the Mie scattering characteristics. A mirror is used to bounce the light back, to have all cameras in forward scattering. Achievable particle density is growing with number of cameras, so eight cameras are used for a high spatial resolution. Optimizations lead to volume size of 230 × 200 × 52 mm3 = 2392 cm3, more than 60 times larger than previously. 281 × 323 × 68 vectors are calculated with spacing of 0.76 mm. The achieved measurement volume size and spatial resolution is regarded as a major step forward in the application of tomo PIV in wind tunnels. Supported by EU-project: no. 265695.
Full-Frame Reference for Test Photo of Moon
NASA Technical Reports Server (NTRS)
2005-01-01
This pair of views shows how little of the full image frame was taken up by the Moon in test images taken Sept. 8, 2005, by the High Resolution Imaging Science Experiment (HiRISE) camera on NASA's Mars Reconnaissance Orbiter. The Mars-bound camera imaged Earth's Moon from a distance of about 10 million kilometers (6 million miles) away -- 26 times the distance between Earth and the Moon -- as part of an activity to test and calibrate the camera. The images are very significant because they show that the Mars Reconnaissance Orbiter spacecraft and this camera can properly operate together to collect very high-resolution images of Mars. The target must move through the camera's telescope view in just the right direction and speed to acquire a proper image. The day's test images also demonstrate that the focus mechanism works properly with the telescope to produce sharp images. Out of the 20,000-pixel-by-6,000-pixel full frame, the Moon's diameter is about 340 pixels, if the full Moon could be seen. The illuminated crescent is about 60 pixels wide, and the resolution is about 10 kilometers (6 miles) per pixel. At Mars, the entire image region will be filled with high-resolution information. The Mars Reconnaissance Orbiter, launched on Aug. 12, 2005, is on course to reach Mars on March 10, 2006. After gradually adjusting the shape of its orbit for half a year, it will begin its primary science phase in November 2006. From the mission's planned science orbit about 300 kilometers (186 miles) above the surface of Mars, the high resolution camera will be able to discern features as small as one meter or yard across. The Mars Reconnaissance Orbiter mission is managed by NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology, Pasadena, for the NASA Science Mission Directorate. Lockheed Martin Space Systems, Denver, prime contractor for the project, built the spacecraft. Ball Aerospace & Technologies Corp., Boulder, Colo., built the High Resolution Imaging Science Experiment instrument for the University of Arizona, Tucson, to provide to the mission. The HiRISE Operations Center at the University of Arizona processes images from the camera.Applications of Action Cam Sensors in the Archaeological Yard
NASA Astrophysics Data System (ADS)
Pepe, M.; Ackermann, S.; Fregonese, L.; Fassi, F.; Adami, A.
2018-05-01
In recent years, special digital cameras called "action camera" or "action cam", have become popular due to their low price, smallness, lightness, strength and capacity to make videos and photos even in extreme environment surrounding condition. Indeed, these particular cameras have been designed mainly to capture sport actions and work even in case of dirt, bumps, or underwater and at different external temperatures. High resolution of Digital single-lens reflex (DSLR) cameras are usually preferred to be employed in photogrammetric field. Indeed, beyond the sensor resolution, the combination of such cameras with fixed lens with low distortion are preferred to perform accurate 3D measurements; at the contrary, action cameras have small and wide-angle lens, with a lower performance in terms of sensor resolution, lens quality and distortions. However, by considering the characteristics of the action cameras to acquire under conditions that may result difficult for standard DSLR cameras and because of their lower price, these could be taken into consideration as a possible and interesting approach during archaeological excavation activities to document the state of the places. In this paper, the influence of lens radial distortion and chromatic aberration on this type of cameras in self-calibration mode and an evaluation of their application in the field of Cultural Heritage will be investigated and discussed. Using a suitable technique, it has been possible to improve the accuracy of the 3D model obtained by action cam images. Case studies show the quality and the utility of the use of this type of sensor in the survey of archaeological artefacts.
Performance evaluation of a quasi-microscope for planetary landers
NASA Technical Reports Server (NTRS)
Burcher, E. E.; Huck, F. O.; Wall, S. D.; Woehrle, S. B.
1977-01-01
Spatial resolutions achieved with cameras on lunar and planetary landers have been limited to about 1 mm, whereas microscopes of the type proposed for such landers could have obtained resolutions of about 1 um but were never accepted because of their complexity and weight. The quasi-microscope evaluated in this paper could provide intermediate resolutions of about 10 um with relatively simple optics that would augment a camera, such as the Viking lander camera, without imposing special design requirements on the camera of limiting its field of view of the terrain. Images of natural particulate samples taken in black and white and in color show that grain size, shape, and texture are made visible for unconsolidated materials in a 50- to 500-um size range. Such information may provide broad outlines of planetary surface mineralogy and allow inferences to be made of grain origin and evolution. The mineralogical descriptions of single grains would be aided by the reflectance spectra that could, for example, be estimated from the six-channel multispectral data of the Viking lander camera.
Microstructure and hardness of carbon and tool steel quenched with high-frequency currents
NASA Astrophysics Data System (ADS)
Fomin, Aleksandr A.; Fedoseev, Maksim E.; Palkanov, Pavel A.; Voyko, Aleksey V.; Fomina, Marina A.; Koshuro, Vladimir A.; Zakharevich, Andrey M.; Kalganova, Svetlana G.; Rodionov, Igor V.
2018-04-01
In the course of high-temperature treatment with high-frequency currents (HFC) in the range from 600 to 1300 °C, carbon and tool steels are strengthened. After the heat treatment the hardness reaches 64-70 HRC for carbon steel (carbon content 0.4-0.5%) and 68-71 HRC for tool steel 1.3343 (R6M5 steel analogue with 0.9-1.0% C content, W - 5-6 wt%, Mo - 3.5-5.3 wt%, V - 1.3-1.8 wt%, Cr - 3.8-4.3 wt%, Mn+Si - 0.5-1 wt%, Fe - balance). The resulting structure is a carbide network, and in the case of tool steel - complex carbides around a high-strength martensitic phase.
Performance Evaluation of 98 CZT Sensors for Their Use in Gamma-Ray Imaging
NASA Astrophysics Data System (ADS)
Dedek, Nicolas; Speller, Robert D.; Spendley, Paul; Horrocks, Julie A.
2008-10-01
98 SPEAR sensors from eV Products have been evaluated for their use in a portable Compton camera. The sensors have a 5 mm times 5 mm times 5 mm CdZnTe crystal and are provided together with a preamplifier. The energy resolution was studied in detail for all sensors and was found to be 6% on average at 59.5 keV and 3% on average at 662 keV. The standard deviations of the corresponding energy resolution distributions are remarkably small (0.6% at 59.5 keV, 0.7% at 662 keV) and reflect the uniformity of the sensor characteristics. For a possible outside use the temperature dependence of the sensor performances was investigated for temperatures between 15 and 45 deg Celsius. A linear shift in calibration with temperature was observed. The energy resolution at low energies (81 keV) was found to deteriorate exponentially with temperature, while it stayed constant at higher energies (356 keV). A Compton camera built of these sensors was simulated. To obtain realistic energy spectra a suitable detector response function was implemented. To investigate the angular resolution of the camera a 137Cs point source was simulated. Reconstructed images of the point source were compared for perfect and realistic energy and position resolutions. The angular resolution of the camera was found to be better than 10 deg.
Free-form reflective optics for mid-infrared camera and spectrometer on board SPICA
NASA Astrophysics Data System (ADS)
Fujishiro, Naofumi; Kataza, Hirokazu; Wada, Takehiko; Ikeda, Yuji; Sakon, Itsuki; Oyabu, Shinki
2017-11-01
SPICA (Space Infrared Telescope for Cosmology and Astrophysics) is an astronomical mission optimized for mid-and far-infrared astronomy with a cryogenically cooled 3-m class telescope, envisioned for launch in early 2020s. Mid-infrared Camera and Spectrometer (MCS) is a focal plane instrument for SPICA with imaging and spectroscopic observing capabilities in the mid-infrared wavelength range of 5-38μm. MCS consists of two relay optical modules and following four scientific optical modules of WFC (Wide Field Camera; 5'x 5' field of view, f/11.7 and f/4.2 cameras), LRS (Low Resolution Spectrometer; 2'.5 long slits, prism dispersers, f/5.0 and f/1.7 cameras, spectral resolving power R ∼ 50-100), MRS (Mid Resolution Spectrometer; echelles, integral field units by image slicer, f/3.3 and f/1.9 cameras, R ∼ 1100-3000) and HRS (High Resolution Spectrometer; immersed echelles, f/6.0 and f/3.6 cameras, R ∼ 20000-30000). Here, we present optical design and expected optical performance of MCS. Most parts of MCS optics adopt off-axis reflective system for covering the wide wavelength range of 5-38μm without chromatic aberration and minimizing problems due to changes in shapes and refractive indices of materials from room temperature to cryogenic temperature. In order to achieve the high specification requirements of wide field of view, small F-number and large spectral resolving power with compact size, we employed the paraxial and aberration analysis of off-axial optical systems (Araki 2005 [1]) which is a design method using free-form surfaces for compact reflective optics such as head mount displays. As a result, we have successfully designed compact reflective optics for MCS with as-built performance of diffraction-limited image resolution.
Time-of-Flight Microwave Camera
Charvat, Gregory; Temme, Andrew; Feigin, Micha; Raskar, Ramesh
2015-01-01
Microwaves can penetrate many obstructions that are opaque at visible wavelengths, however microwave imaging is challenging due to resolution limits associated with relatively small apertures and unrecoverable “stealth” regions due to the specularity of most objects at microwave frequencies. We demonstrate a multispectral time-of-flight microwave imaging system which overcomes these challenges with a large passive aperture to improve lateral resolution, multiple illumination points with a data fusion method to reduce stealth regions, and a frequency modulated continuous wave (FMCW) receiver to achieve depth resolution. The camera captures images with a resolution of 1.5 degrees, multispectral images across the X frequency band (8 GHz–12 GHz), and a time resolution of 200 ps (6 cm optical path in free space). Images are taken of objects in free space as well as behind drywall and plywood. This architecture allows “camera-like” behavior from a microwave imaging system and is practical for imaging everyday objects in the microwave spectrum. PMID:26434598
MPGD for breast cancer prevention: a high resolution and low dose radiation medical imaging
NASA Astrophysics Data System (ADS)
Gutierrez, R. M.; Cerquera, E. A.; Mañana, G.
2012-07-01
Early detection of small calcifications in mammograms is considered the best preventive tool of breast cancer. However, existing digital mammography with relatively low radiation skin exposure has limited accessibility and insufficient spatial resolution for small calcification detection. Micro Pattern Gaseous Detectors (MPGD) and associated technologies, increasingly provide new information useful to generate images of microscopic structures and make more accessible cutting edge technology for medical imaging and many other applications. In this work we foresee and develop an application for the new information provided by a MPGD camera in the form of highly controlled images with high dynamical resolution. We present a new Super Detail Image (S-DI) that efficiently profits of this new information provided by the MPGD camera to obtain very high spatial resolution images. Therefore, the method presented in this work shows that the MPGD camera with SD-I, can produce mammograms with the necessary spatial resolution to detect microcalcifications. It would substantially increase efficiency and accessibility of screening mammography to highly improve breast cancer prevention.
Time-of-Flight Microwave Camera
NASA Astrophysics Data System (ADS)
Charvat, Gregory; Temme, Andrew; Feigin, Micha; Raskar, Ramesh
2015-10-01
Microwaves can penetrate many obstructions that are opaque at visible wavelengths, however microwave imaging is challenging due to resolution limits associated with relatively small apertures and unrecoverable “stealth” regions due to the specularity of most objects at microwave frequencies. We demonstrate a multispectral time-of-flight microwave imaging system which overcomes these challenges with a large passive aperture to improve lateral resolution, multiple illumination points with a data fusion method to reduce stealth regions, and a frequency modulated continuous wave (FMCW) receiver to achieve depth resolution. The camera captures images with a resolution of 1.5 degrees, multispectral images across the X frequency band (8 GHz-12 GHz), and a time resolution of 200 ps (6 cm optical path in free space). Images are taken of objects in free space as well as behind drywall and plywood. This architecture allows “camera-like” behavior from a microwave imaging system and is practical for imaging everyday objects in the microwave spectrum.
High resolution bone mineral densitometry with a gamma camera
NASA Technical Reports Server (NTRS)
Leblanc, A.; Evans, H.; Jhingran, S.; Johnson, P.
1983-01-01
A technique by which the regional distribution of bone mineral can be determined in bone samples from small animals is described. The technique employs an Anger camera interfaced to a medical computer. High resolution imaging is possible by producing magnified images of the bone samples. Regional densitometry of femurs from oophorectomised and bone mineral loss.
SU-E-J-197: Investigation of Microsoft Kinect 2.0 Depth Resolution for Patient Motion Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silverstein, E; Snyder, M
2015-06-15
Purpose: Investigate the use of the Kinect 2.0 for patient motion tracking during radiotherapy by studying spatial and depth resolution capabilities. Methods: Using code written in C#, depth map data was abstracted from the Kinect to create an initial depth map template indicative of the initial position of an object to be compared to the depth map of the object over time. To test this process, simple setup was created in which two objects were imaged: a 40 cm × 40 cm board covered in non reflective material and a 15 cm × 26 cm textbook with a slightly reflective,more » glossy cover. Each object, imaged and measured separately, was placed on a movable platform with object to camera distance measured. The object was then moved a specified amount to ascertain whether the Kinect’s depth camera would visualize the difference in position of the object. Results: Initial investigations have shown the Kinect depth resolution is dependent on the object to camera distance. Measurements indicate that movements as small as 1 mm can be visualized for objects as close as 50 cm away. This depth resolution decreases linearly with object to camera distance. At 4 m, the depth resolution had decreased to observe a minimum movement of 1 cm. Conclusion: The improved resolution and advanced hardware of the Kinect 2.0 allows for increase of depth resolution over the Kinect 1.0. Although obvious that the depth resolution should decrease with increasing distance from an object given the decrease in number of pixels representing said object, the depth resolution at large distances indicates its usefulness in a clinical setting.« less
Study of a quasi-microscope design for planetary landers
NASA Technical Reports Server (NTRS)
Giat, O.; Brown, E. B.
1973-01-01
The Viking Lander fascimile camera, in its present form, provides for a minimum object distance of 1.9 meters, at which distance its resolution of 0.0007 radian provides an object resolution of 1.33 millimeters. It was deemed desirable, especially for follow-on Viking missions, to provide means for examing Martian terrain at resolutions considerably higher than that now provided. This led to the concept of quasi-microscope, an attachment to be used in conjunction with the fascimile camera to convert it to a low power microscope. The results are reported of an investigation to consider alternate optical configurations for the quasi-microscope and to develop optical designs for the selected system or systems. Initial requirements included consideration of object resolutions in the range of 2 to 50 micrometers, an available field of view of the order of 500 pixels, and no significant modifications to the fascimile camera.
A high-speed digital camera system for the observation of rapid H-alpha fluctuations in solar flares
NASA Technical Reports Server (NTRS)
Kiplinger, Alan L.; Dennis, Brian R.; Orwig, Larry E.
1989-01-01
Researchers developed a prototype digital camera system for obtaining H-alpha images of solar flares with 0.1 s time resolution. They intend to operate this system in conjunction with SMM's Hard X Ray Burst Spectrometer, with x ray instruments which will be available on the Gamma Ray Observatory and eventually with the Gamma Ray Imaging Device (GRID), and with the High Resolution Gamma-Ray and Hard X Ray Spectrometer (HIREGS) which are being developed for the Max '91 program. The digital camera has recently proven to be successful as a one camera system operating in the blue wing of H-alpha during the first Max '91 campaign. Construction and procurement of a second and possibly a third camera for simultaneous observations at other wavelengths are underway as are analyses of the campaign data.
Science Instruments for the Advanced X-Ray Astrophysics Facility (AXAF)
NASA Technical Reports Server (NTRS)
Winkler, Carl E.; Cumings, Nesbitt P.; Randolph, Joseph L.; Talley, Drayton H.
1993-01-01
The AXAF program has undergone major changes since the Announcement of Opportunity was extended by NASA Headquarters in 1983. The Science Instruments (SI's) for AXAF have also experienced several design changes since they were competitively selected in 1985. Moreover, two separate complementary missions are now being baselined for AXAF; one is designated AXAF-I for imaging and will include the high precision Wolter type I optics, and the other is called AXAF-S for spectroscopy. The resulting less-costly AXAF will still be superior to any previous x-ray observatories. Both missions continue to be managed. AXAF-I contains two focal plane SI's, the High Resolution Camera (HRC), and the AXAF Charge-Coupled Device (CCD) imaging spectrometer (ACIS), as well as the High-Energy Transmission Grating Spectrometer (HETGS) and the Low-Energy Transmission Grating Spectrometer (LETGS). Optics/Cryogenics Division (BECD). AXAF-S features only one focal plane SI, the X-Ray Spectrometer (XRS). The grazing incidence mirrors for this mission are mainly to provide a large collecting area and to concentrate these x-ray photons onto the XRS detector. Precise focusing, although preferred, is of secondary importance. Nested conical foil mirrors are currently baselined; however, replicated imaging optics are being evaluated for collecting efficiency and cost. AXAF-S is scheduled to be launched in late 1999. It has been designated as an MSFC in-house project. In addition to overall management, MSFC is fully responsible for the design, development, integration, and test of the complete AXAF-S observatory, including the XRS which will be furnished by the Goddard Space Flight Center (GSFC). Together, AXAF-I and AXAF-S constitute the third of NASA's series of Great Observatories, joining the Hubble space telescope (HST) and the Gamma-Ray Observatory (GRO) which are already operational. The develop- ment, launch, and operation of the Space InfraRed Telescope Facility (SIRTF) will follow later to complete the Great Observatory series. This paper summarizes the impact these changes have had on the SI's.
Wide-Field-of-View, High-Resolution, Stereoscopic Imager
NASA Technical Reports Server (NTRS)
Prechtl, Eric F.; Sedwick, Raymond J.
2010-01-01
A device combines video feeds from multiple cameras to provide wide-field-of-view, high-resolution, stereoscopic video to the user. The prototype under development consists of two camera assemblies, one for each eye. One of these assemblies incorporates a mounting structure with multiple cameras attached at offset angles. The video signals from the cameras are fed to a central processing platform where each frame is color processed and mapped into a single contiguous wide-field-of-view image. Because the resolution of most display devices is typically smaller than the processed map, a cropped portion of the video feed is output to the display device. The positioning of the cropped window will likely be controlled through the use of a head tracking device, allowing the user to turn his or her head side-to-side or up and down to view different portions of the captured image. There are multiple options for the display of the stereoscopic image. The use of head mounted displays is one likely implementation. However, the use of 3D projection technologies is another potential technology under consideration, The technology can be adapted in a multitude of ways. The computing platform is scalable, such that the number, resolution, and sensitivity of the cameras can be leveraged to improve image resolution and field of view. Miniaturization efforts can be pursued to shrink the package down for better mobility. Power savings studies can be performed to enable unattended, remote sensing packages. Image compression and transmission technologies can be incorporated to enable an improved telepresence experience.
Continuous All-Sky Cloud Measurements: Cloud Fraction Analysis Based on a Newly Developed Instrument
NASA Astrophysics Data System (ADS)
Aebi, C.; Groebner, J.; Kaempfer, N.; Vuilleumier, L.
2017-12-01
Clouds play an important role in the climate system and are also a crucial parameter for the Earth's surface energy budget. Ground-based measurements of clouds provide data in a high temporal resolution in order to quantify its influence on radiation. The newly developed all-sky cloud camera at PMOD/WRC in Davos (Switzerland), the infrared cloud camera (IRCCAM), is a microbolometer sensitive in the 8 - 14 μm wavelength range. To get all-sky information the camera is located on top of a frame looking downward on a spherical gold-plated mirror. The IRCCAM has been measuring continuously (day and nighttime) with a time resolution of one minute in Davos since September 2015. To assess the performance of the IRCCAM, two different visible all-sky cameras (Mobotix Q24M and Schreder VIS-J1006), which can only operate during daytime, are installed in Davos. All three camera systems have different software for calculating fractional cloud coverage from images. Our study analyzes mainly the fractional cloud coverage of the IRCCAM and compares it with the fractional cloud coverage calculated from the two visible cameras. Preliminary results of the measurement accuracy of the IRCCAM compared to the visible camera indicate that 78 % of the data are within ± 1 octa and even 93 % within ± 2 octas. An uncertainty of 1-2 octas corresponds to the measurement uncertainty of human observers. Therefore, the IRCCAM shows similar performance in detection of cloud coverage as the visible cameras and the human observers, with the advantage that continuous measurements with high temporal resolution are possible.
Minimum Requirements for Taxicab Security Cameras*
Zeng, Shengke; Amandus, Harlan E.; Amendola, Alfred A.; Newbraugh, Bradley H.; Cantis, Douglas M.; Weaver, Darlene
2015-01-01
Problem The homicide rate of taxicab-industry is 20 times greater than that of all workers. A NIOSH study showed that cities with taxicab-security cameras experienced significant reduction in taxicab driver homicides. Methods Minimum technical requirements and a standard test protocol for taxicab-security cameras for effective taxicab-facial identification were determined. The study took more than 10,000 photographs of human-face charts in a simulated-taxicab with various photographic resolutions, dynamic ranges, lens-distortions, and motion-blurs in various light and cab-seat conditions. Thirteen volunteer photograph-evaluators evaluated these face photographs and voted for the minimum technical requirements for taxicab-security cameras. Results Five worst-case scenario photographic image quality thresholds were suggested: the resolution of XGA-format, highlight-dynamic-range of 1 EV, twilight-dynamic-range of 3.3 EV, lens-distortion of 30%, and shutter-speed of 1/30 second. Practical Applications These minimum requirements will help taxicab regulators and fleets to identify effective taxicab-security cameras, and help taxicab-security camera manufacturers to improve the camera facial identification capability. PMID:26823992
Cheetah: A high frame rate, high resolution SWIR image camera
NASA Astrophysics Data System (ADS)
Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob
2008-10-01
A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.
Development and calibration of a new gamma camera detector using large square Photomultiplier Tubes
NASA Astrophysics Data System (ADS)
Zeraatkar, N.; Sajedi, S.; Teimourian Fard, B.; Kaviani, S.; Akbarzadeh, A.; Farahani, M. H.; Sarkar, S.; Ay, M. R.
2017-09-01
Large area scintillation detectors applied in gamma cameras as well as Single Photon Computed Tomography (SPECT) systems, have a major role in in-vivo functional imaging. Most of the gamma detectors utilize hexagonal arrangement of Photomultiplier Tubes (PMTs). In this work we applied large square-shaped PMTs with row/column arrangement and positioning. The Use of large square PMTs reduces dead zones in the detector surface. However, the conventional center of gravity method for positioning may not introduce an acceptable result. Hence, the digital correlated signal enhancement (CSE) algorithm was optimized to obtain better linearity and spatial resolution in the developed detector. The performance of the developed detector was evaluated based on NEMA-NU1-2007 standard. The acquired images using this method showed acceptable uniformity and linearity comparing to three commercial gamma cameras. Also the intrinsic and extrinsic spatial resolutions with low-energy high-resolution (LEHR) collimator at 10 cm from surface of the detector were 3.7 mm and 7.5 mm, respectively. The energy resolution of the camera was measured 9.5%. The performance evaluation demonstrated that the developed detector maintains image quality with a reduced number of used PMTs relative to the detection area.
640 x 480 MWIR and LWIR camera system developments
NASA Astrophysics Data System (ADS)
Tower, John R.; Villani, Thomas S.; Esposito, Benjamin J.; Gilmartin, Harvey R.; Levine, Peter A.; Coyle, Peter J.; Davis, Timothy J.; Shallcross, Frank V.; Sauer, Donald J.; Meyerhofer, Dietrich
1993-01-01
The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.
640 x 480 MWIR and LWIR camera system developments
NASA Astrophysics Data System (ADS)
Tower, J. R.; Villani, T. S.; Esposito, B. J.; Gilmartin, H. R.; Levine, P. A.; Coyle, P. J.; Davis, T. J.; Shallcross, F. V.; Sauer, D. J.; Meyerhofer, D.
The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.
Streak camera receiver definition study
NASA Technical Reports Server (NTRS)
Johnson, C. B.; Hunkler, L. T., Sr.; Letzring, S. A.; Jaanimagi, P.
1990-01-01
Detailed streak camera definition studies were made as a first step toward full flight qualification of a dual channel picosecond resolution streak camera receiver for the Geoscience Laser Altimeter and Ranging System (GLRS). The streak camera receiver requirements are discussed as they pertain specifically to the GLRS system, and estimates of the characteristics of the streak camera are given, based upon existing and near-term technological capabilities. Important problem areas are highlighted, and possible corresponding solutions are discussed.
NASA Astrophysics Data System (ADS)
Brown, T.; Borevitz, J. O.; Zimmermann, C.
2010-12-01
We have a developed a camera system that can record hourly, gigapixel (multi-billion pixel) scale images of an ecosystem in a 360x90 degree panorama. The “Gigavision” camera system is solar-powered and can wirelessly stream data to a server. Quantitative data collection from multiyear timelapse gigapixel images is facilitated through an innovative web-based toolkit for recording time-series data on developmental stages (phenology) from any plant in the camera’s field of view. Gigapixel images enable time-series recording of entire landscapes with a resolution sufficient to record phenology from a majority of individuals in entire populations of plants. When coupled with next generation sequencing, quantitative population genomics can be performed in a landscape context linking ecology and evolution in situ and in real time. The Gigavision camera system achieves gigapixel image resolution by recording rows and columns of overlapping megapixel images. These images are stitched together into a single gigapixel resolution image using commercially available panorama software. Hardware consists of a 5-18 megapixel resolution DSLR or Network IP camera mounted on a pair of heavy-duty servo motors that provide pan-tilt capabilities. The servos and camera are controlled with a low-power Windows PC. Servo movement, power switching, and system status monitoring are enabled with Phidgets-brand sensor boards. System temperature, humidity, power usage, and battery voltage are all monitored at 5 minute intervals. All sensor data is uploaded via cellular or 802.11 wireless to an interactive online interface for easy remote monitoring of system status. Systems with direct internet connections upload the full sized images directly to our automated stitching server where they are stitched and available online for viewing within an hour of capture. Systems with cellular wireless upload an 80 megapixel “thumbnail” of each larger panorama and full-sized images are manually retrieved at bi-weekly intervals. Our longer-term goal is to make gigapixel time-lapse datasets available online in an interactive interface that layers plant-level phenology data with gigapixel resolution images, genomic sequence data from individual plants with weather and other abitotic sensor data. Co-visualization of all of these data types provides researchers with a powerful new tool for examining complex ecological interactions across scales from the individual to the ecosystem. We will present detailed phenostage data from more than 100 plants of multiple species from our Gigavision timelapse camera at our “Big Blowout East” field site in the Indiana Dunes State Park, IN. This camera has been recording three to four 700 million pixel images a day since February 28, 2010. The camera field of view covers an area of about 7 hectares resulting in an average image resolution of about 1 pixel per centimeter over the entire site. We will also discuss some of the many technological challenges with developing and maintaining these types of hardware systems, collecting quantitative data from gigapixel resolution time-lapse data and effectively managing terabyte-sized datasets of millions of images.
Thermographic measurements of high-speed metal cutting
NASA Astrophysics Data System (ADS)
Mueller, Bernhard; Renz, Ulrich
2002-03-01
Thermographic measurements of a high-speed cutting process have been performed with an infrared camera. To realize images without motion blur the integration times were reduced to a few microseconds. Since the high tool wear influences the measured temperatures a set-up has been realized which enables small cutting lengths. Only single images have been recorded because the process is too fast to acquire a sequence of images even with the frame rate of the very fast infrared camera which has been used. To expose the camera when the rotating tool is in the middle of the camera image an experimental set-up with a light barrier and a digital delay generator with a time resolution of 1 ns has been realized. This enables a very exact triggering of the camera at the desired position of the tool in the image. Since the cutting depth is between 0.1 and 0.2 mm a high spatial resolution was also necessary which was obtained by a special close-up lens allowing a resolution of app. 45 microns. The experimental set-up will be described and infrared images and evaluated temperatures of a titanium alloy and a carbon steel will be presented for cutting speeds up to 42 m/s.
Medium-sized aperture camera for Earth observation
NASA Astrophysics Data System (ADS)
Kim, Eugene D.; Choi, Young-Wan; Kang, Myung-Seok; Kim, Ee-Eul; Yang, Ho-Soon; Rasheed, Ad. Aziz Ad.; Arshad, Ahmad Sabirin
2017-11-01
Satrec Initiative and ATSB have been developing a medium-sized aperture camera (MAC) for an earth observation payload on a small satellite. Developed as a push-broom type high-resolution camera, the camera has one panchromatic and four multispectral channels. The panchromatic channel has 2.5m, and multispectral channels have 5m of ground sampling distances at a nominal altitude of 685km. The 300mm-aperture Cassegrain telescope contains two aspheric mirrors and two spherical correction lenses. With a philosophy of building a simple and cost-effective camera, the mirrors incorporate no light-weighting, and the linear CCDs are mounted on a single PCB with no beam splitters. MAC is the main payload of RazakSAT to be launched in 2005. RazakSAT is a 180kg satellite including MAC, designed to provide high-resolution imagery of 20km swath width on a near equatorial orbit (NEqO). The mission objective is to demonstrate the capability of a high-resolution remote sensing satellite system on a near equatorial orbit. This paper describes the overview of the MAC and RarakSAT programmes, and presents the current development status of MAC focusing on key optical aspects of Qualification Model.
Digital Camera Control for Faster Inspection
NASA Technical Reports Server (NTRS)
Brown, Katharine; Siekierski, James D.; Mangieri, Mark L.; Dekome, Kent; Cobarruvias, John; Piplani, Perry J.; Busa, Joel
2009-01-01
Digital Camera Control Software (DCCS) is a computer program for controlling a boom and a boom-mounted camera used to inspect the external surface of a space shuttle in orbit around the Earth. Running in a laptop computer in the space-shuttle crew cabin, DCCS commands integrated displays and controls. By means of a simple one-button command, a crewmember can view low- resolution images to quickly spot problem areas and can then cause a rapid transition to high- resolution images. The crewmember can command that camera settings apply to a specific small area of interest within the field of view of the camera so as to maximize image quality within that area. DCCS also provides critical high-resolution images to a ground screening team, which analyzes the images to assess damage (if any); in so doing, DCCS enables the team to clear initially suspect areas more quickly than would otherwise be possible and further saves time by minimizing the probability of re-imaging of areas already inspected. On the basis of experience with a previous version (2.0) of the software, the present version (3.0) incorporates a number of advanced imaging features that optimize crewmember capability and efficiency.
Processing Issues for Preliminary Melts of the Intermetallic Compound 60-NITINOL
NASA Technical Reports Server (NTRS)
Stanford, Malcolm K.; Thomas, Fransua; DellaCorte, Christopher
2012-01-01
The effect of various high temperature heat treatments and cooling rates on the hardness of cast 60-NITINOL (60wt%Ni- 40wt%Ti) was studied. The hardness ranged from approximately 33 HRC for annealed specimens to 63 HRC for water quenched specimens. Aging did not have a further effect on the hardness of the heat-treated and quenched material. The issue of material contamination and its possible effect on quench cracking during heat treatment above 1000 C was explored. The Charpy impact energy of the material was found to be relatively low (ranging from 0.4 to 1.0 J) and comparable to that of cast magnesium. Selection of service environments and applications for this material based on these findings should consider the processing route by which it was produced.
Impact of laser phase and amplitude noises on streak camera temporal resolution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wlotzko, V., E-mail: wlotzko@optronis.com; Optronis GmbH, Ludwigstrasse 2, 77694 Kehl; Uhring, W.
2015-09-15
Streak cameras are now reaching sub-picosecond temporal resolution. In cumulative acquisition mode, this resolution does not entirely rely on the electronic or the vacuum tube performances but also on the light source characteristics. The light source, usually an actively mode-locked laser, is affected by phase and amplitude noises. In this paper, the theoretical effects of such noises on the synchronization of the streak system are studied in synchroscan and triggered modes. More precisely, the contribution of band-pass filters, delays, and time walk is ascertained. Methods to compute the resulting synchronization jitter are depicted. The results are verified by measurement withmore » a streak camera combined with a Ti:Al{sub 2}O{sub 3} solid state laser oscillator and also a fiber oscillator.« less
Speed of sound and photoacoustic imaging with an optical camera based ultrasound detection system
NASA Astrophysics Data System (ADS)
Nuster, Robert; Paltauf, Guenther
2017-07-01
CCD camera based optical ultrasound detection is a promising alternative approach for high resolution 3D photoacoustic imaging (PAI). To fully exploit its potential and to achieve an image resolution <50 μm, it is necessary to incorporate variations of the speed of sound (SOS) in the image reconstruction algorithm. Hence, in the proposed work the idea and a first implementation are shown how speed of sound imaging can be added to a previously developed camera based PAI setup. The current setup provides SOS-maps with a spatial resolution of 2 mm and an accuracy of the obtained absolute SOS values of about 1%. The proposed dual-modality setup has the potential to provide highly resolved and perfectly co-registered 3D photoacoustic and SOS images.
4K Video of Colorful Liquid in Space
2015-10-09
Once again, astronauts on the International Space Station dissolved an effervescent tablet in a floating ball of water, and captured images using a camera capable of recording four times the resolution of normal high-definition cameras. The higher resolution images and higher frame rate videos can reveal more information when used on science investigations, giving researchers a valuable new tool aboard the space station. This footage is one of the first of its kind. The cameras are being evaluated for capturing science data and vehicle operations by engineers at NASA's Marshall Space Flight Center in Huntsville, Alabama.
Performance of Laser Megajoule’s x-ray streak camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuber, C., E-mail: celine.zuber@cea.fr; Bazzoli, S.; Brunel, P.
2016-11-15
A prototype of a picosecond x-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to provide plasma-diagnostic support for the Laser Megajoule. We report on the measured performance of this streak camera, which almost fulfills the requirements: 50-μm spatial resolution over a 15-mm field in the photocathode plane, 17-ps temporal resolution in a 2-ns timebase, a detection threshold lower than 625 nJ/cm{sup 2} in the 0.05–15 keV spectral range, and a dynamic range greater than 100.
High-Resolution Surface Reconstruction from Imagery for Close Range Cultural Heritage Applications
NASA Astrophysics Data System (ADS)
Wenzel, K.; Abdel-Wahab, M.; Cefalu, A.; Fritsch, D.
2012-07-01
The recording of high resolution point clouds with sub-mm resolution is a demanding and cost intensive task, especially with current equipment like handheld laser scanners. We present an image based approached, where techniques of image matching and dense surface reconstruction are combined with a compact and affordable rig of off-the-shelf industry cameras. Such cameras provide high spatial resolution with low radiometric noise, which enables a one-shot solution and thus an efficient data acquisition while satisfying high accuracy requirements. However, the largest drawback of image based solutions is often the acquisition of surfaces with low texture where the image matching process might fail. Thus, an additional structured light projector is employed, represented here by the pseudo-random pattern projector of the Microsoft Kinect. Its strong infrared-laser projects speckles of different sizes. By using dense image matching techniques on the acquired images, a 3D point can be derived for almost each pixel. The use of multiple cameras enables the acquisition of a high resolution point cloud with high accuracy for each shot. For the proposed system up to 3.5 Mio. 3D points with sub-mm accuracy can be derived per shot. The registration of multiple shots is performed by Structure and Motion reconstruction techniques, where feature points are used to derive the camera positions and rotations automatically without initial information.
High-Resolution Scintimammography: A Pilot Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rachel F. Brem; Joelle M. Schoonjans; Douglas A. Kieper
2002-07-01
This study evaluated a novel high-resolution breast-specific gamma camera (HRBGC) for the detection of suggestive breast lesions. Methods: Fifty patients (with 58 breast lesions) for whom a scintimammogram was clinically indicated were prospectively evaluated with a general-purpose gamma camera and a novel HRBGC prototype. The results of conventional and high-resolution nuclear studies were prospectively classified as negative (normal or benign) or positive (suggestive or malignant) by 2 radiologists who were unaware of the mammographic and histologic results. All of the included lesions were confirmed by pathology. Results: There were 30 benign and 28 malignant lesions. The sensitivity for detection ofmore » breast cancer was 64.3% (18/28) with the conventional camera and 78.6% (22/28) with the HRBGC. The specificity with both systems was 93.3% (28/30). For the 18 nonpalpable lesions, sensitivity was 55.5% (10/18) and 72.2% (13/18) with the general-purpose camera and the HRBGC, respectively. For lesions 1 cm, 7 of 15 were detected with the general-purpose camera and 10 of 15 with the HRBGC. Four lesions (median size, 8.5 mm) were detected only with the HRBGC and were missed by the conventional camera. Conclusion: Evaluation of indeterminate breast lesions with an HRBGC results in improved sensitivity for the detection of cancer, with greater improvement shown for nonpalpable and 1-cm lesions.« less
Generalized assorted pixel camera: postcapture control of resolution, dynamic range, and spectrum.
Yasuma, Fumihito; Mitsunaga, Tomoo; Iso, Daisuke; Nayar, Shree K
2010-09-01
We propose the concept of a generalized assorted pixel (GAP) camera, which enables the user to capture a single image of a scene and, after the fact, control the tradeoff between spatial resolution, dynamic range and spectral detail. The GAP camera uses a complex array (or mosaic) of color filters. A major problem with using such an array is that the captured image is severely under-sampled for at least some of the filter types. This leads to reconstructed images with strong aliasing. We make four contributions in this paper: 1) we present a comprehensive optimization method to arrive at the spatial and spectral layout of the color filter array of a GAP camera. 2) We develop a novel algorithm for reconstructing the under-sampled channels of the image while minimizing aliasing artifacts. 3) We demonstrate how the user can capture a single image and then control the tradeoff of spatial resolution to generate a variety of images, including monochrome, high dynamic range (HDR) monochrome, RGB, HDR RGB, and multispectral images. 4) Finally, the performance of our GAP camera has been verified using extensive simulations that use multispectral images of real world scenes. A large database of these multispectral images has been made available at http://www1.cs.columbia.edu/CAVE/projects/gap_camera/ for use by the research community.
Instrumentation in molecular imaging.
Wells, R Glenn
2016-12-01
In vivo molecular imaging is a challenging task and no single type of imaging system provides an ideal solution. Nuclear medicine techniques like SPECT and PET provide excellent sensitivity but have poor spatial resolution. Optical imaging has excellent sensitivity and spatial resolution, but light photons interact strongly with tissues and so only small animals and targets near the surface can be accurately visualized. CT and MRI have exquisite spatial resolution, but greatly reduced sensitivity. To overcome the limitations of individual modalities, molecular imaging systems often combine individual cameras together, for example, merging nuclear medicine cameras with CT or MRI to allow the visualization of molecular processes with both high sensitivity and high spatial resolution.
High-resolution mini gamma camera for diagnosis and radio-guided surgery in diabetic foot infection
NASA Astrophysics Data System (ADS)
Scopinaro, F.; Capriotti, G.; Di Santo, G.; Capotondi, C.; Micarelli, A.; Massari, R.; Trotta, C.; Soluri, A.
2006-12-01
The diagnosis of diabetic foot osteomyelitis is often difficult. 99mTc-WBC (White Blood Cell) scintigraphy plays a key role in the diagnosis of bone infections. Spatial resolution of Anger camera is not always able to differentiate soft tissue from bone infection. Aim of present study is to verify if HRD (High-Resolution Detector) is able to improve diagnosis and to help surgery. Patients were studied by HRD showing 25.7×25.7 mm 2 FOV, 2 mm spatial resolution and 18% energy resolution. The patients were underwent to surgery and, when necessary, bone biopsy, both guided by HRD. Four patients were positive at Anger camera without specific signs of osteomyelitis. HRS (High-Resolution Scintigraphy) showed hot spots in the same patients. In two of them the hot spot was bar-shaped and it was localized in correspondence of the small phalanx. The presence of bone infection was confirmed at surgery, which was successfully guided by HRS. 99mTc-WBC HRS was able to diagnose pedal infection and to guide the surgery of diabetic foot, opening a new way in the treatment of infected diabetic foot.
Gate simulation of Compton Ar-Xe gamma-camera for radionuclide imaging in nuclear medicine
NASA Astrophysics Data System (ADS)
Dubov, L. Yu; Belyaev, V. N.; Berdnikova, A. K.; Bolozdynia, A. I.; Akmalova, Yu A.; Shtotsky, Yu V.
2017-01-01
Computer simulations of cylindrical Compton Ar-Xe gamma camera are described in the current report. Detection efficiency of cylindrical Ar-Xe Compton camera with internal diameter of 40 cm is estimated as1-3%that is 10-100 times higher than collimated Anger’s camera. It is shown that cylindrical Compton camera can image Tc-99m radiotracer distribution with uniform spatial resolution of 20 mm through the whole field of view.
NASA Astrophysics Data System (ADS)
Trofimov, Vyacheslav A.; Trofimov, Vladislav V.; Kuchik, Igor E.
2014-06-01
As it is well-known, application of the passive THz camera for the security problems is very promising way. It allows seeing concealed object without contact with a person and this camera is non-dangerous for a person. We demonstrate new possibility of the passive THz camera using for a temperature difference observing on the human skin if this difference is caused by different temperatures inside the body. We discuss some physical experiments, in which a person drinks hot, and warm, and cold water and he eats. After computer processing of images captured by passive THz camera TS4 we may see the pronounced temperature trace on skin of the human body. For proof of validity of our statement we make the similar physical experiment using the IR camera. Our investigation allows to increase field of the passive THz camera using for the detection of objects concealed in the human body because the difference in temperature between object and parts of human body will be reflected on the human skin. However, modern passive THz cameras have not enough resolution in a temperature to see this difference. That is why, we use computer processing to enhance the camera resolution for this application. We consider images produced by THz passive cameras manufactured by Microsemi Corp., and ThruVision Corp.
Endockscope: using mobile technology to create global point of service endoscopy.
Sohn, William; Shreim, Samir; Yoon, Renai; Huynh, Victor B; Dash, Atreya; Clayman, Ralph; Lee, Hak J
2013-09-01
Recent advances and the widespread availability of smartphones have ushered in a new wave of innovations in healthcare. We present our initial experience with Endockscope, a new docking system that optimizes the coupling of the iPhone 4S with modern endoscopes. Using the United States Air Force resolution target, we compared the image resolution (line pairs/mm) of a flexible cystoscope coupled to the Endockscope+iPhone to the Storz high definition (HD) camera (H3-Z Versatile). We then used the Munsell ColorChecker chart to compare the color resolution with a 0° laparoscope. Furthermore, 12 expert endoscopists blindly compared and evaluated images from a porcine model using a cystoscope and ureteroscope for both systems. Finally, we also compared the cost (average of two company listed prices) and weight (lb) of the two systems. Overall, the image resolution allowed by the Endockscope was identical to the traditional HD camera (4.49 vs 4.49 lp/mm). Red (ΔE=9.26 vs 9.69) demonstrated better color resolution for iPhone, but green (ΔE=7.76 vs 10.95), and blue (ΔE=12.35 vs 14.66) revealed better color resolution with the Storz HD camera. Expert reviews of cystoscopic images acquired with the HD camera were superior in image, color, and overall quality (P=0.002, 0.042, and 0.003). In contrast, the ureteroscopic reviews yielded no statistical difference in image, color, and overall (P=1, 0.203, and 0.120) quality. The overall cost of the Endockscope+iPhone was $154 compared with $46,623 for a standard HD system. The weight of the mobile-coupled system was 0.47 lb and 1.01 lb for the Storz HD camera. Endockscope demonstrated feasibility of coupling endoscopes to a smartphone. The lighter and inexpensive Endockscope acquired images of the same resolution and acceptable color resolution. When evaluated by expert endoscopists, the quality of the images overall were equivalent for flexible ureteroscopy and somewhat inferior, but still acceptable for flexible cystoscopy.
Endockscope: Using Mobile Technology to Create Global Point of Service Endoscopy
Sohn, William; Shreim, Samir; Yoon, Renai; Huynh, Victor B.; Dash, Atreya; Clayman, Ralph
2013-01-01
Abstract Background and Purpose Recent advances and the widespread availability of smartphones have ushered in a new wave of innovations in healthcare. We present our initial experience with Endockscope, a new docking system that optimizes the coupling of the iPhone 4S with modern endoscopes. Materials and Methods Using the United States Air Force resolution target, we compared the image resolution (line pairs/mm) of a flexible cystoscope coupled to the Endockscope+iPhone to the Storz high definition (HD) camera (H3-Z Versatile). We then used the Munsell ColorChecker chart to compare the color resolution with a 0° laparoscope. Furthermore, 12 expert endoscopists blindly compared and evaluated images from a porcine model using a cystoscope and ureteroscope for both systems. Finally, we also compared the cost (average of two company listed prices) and weight (lb) of the two systems. Results Overall, the image resolution allowed by the Endockscope was identical to the traditional HD camera (4.49 vs 4.49 lp/mm). Red (ΔE=9.26 vs 9.69) demonstrated better color resolution for iPhone, but green (ΔE=7.76 vs 10.95), and blue (ΔE=12.35 vs 14.66) revealed better color resolution with the Storz HD camera. Expert reviews of cystoscopic images acquired with the HD camera were superior in image, color, and overall quality (P=0.002, 0.042, and 0.003). In contrast, the ureteroscopic reviews yielded no statistical difference in image, color, and overall (P=1, 0.203, and 0.120) quality. The overall cost of the Endockscope+iPhone was $154 compared with $46,623 for a standard HD system. The weight of the mobile-coupled system was 0.47 lb and 1.01 lb for the Storz HD camera. Conclusion Endockscope demonstrated feasibility of coupling endoscopes to a smartphone. The lighter and inexpensive Endockscope acquired images of the same resolution and acceptable color resolution. When evaluated by expert endoscopists, the quality of the images overall were equivalent for flexible ureteroscopy and somewhat inferior, but still acceptable for flexible cystoscopy. PMID:23701228
Otto, Kristen J; Hapner, Edie R; Baker, Michael; Johns, Michael M
2006-02-01
Advances in commercial video technology have improved office-based laryngeal imaging. This study investigates the perceived image quality of a true high-definition (HD) video camera and the effect of magnification on laryngeal videostroboscopy. We performed a prospective, dual-armed, single-blinded analysis of a standard laryngeal videostroboscopic examination comparing 3 separate add-on camera systems: a 1-chip charge-coupled device (CCD) camera, a 3-chip CCD camera, and a true 720p (progressive scan) HD camera. Displayed images were controlled for magnification and image size (20-inch [50-cm] display, red-green-blue, and S-video cable for 1-chip and 3-chip cameras; digital visual interface cable and HD monitor for HD camera). Ten blinded observers were then asked to rate the following 5 items on a 0-to-100 visual analog scale: resolution, color, ability to see vocal fold vibration, sense of depth perception, and clarity of blood vessels. Eight unblinded observers were then asked to rate the difference in perceived resolution and clarity of laryngeal examination images when displayed on a 10-inch (25-cm) monitor versus a 42-inch (105-cm) monitor. A visual analog scale was used. These monitors were controlled for actual resolution capacity. For each item evaluated, randomized block design analysis demonstrated that the 3-chip camera scored significantly better than the 1-chip camera (p < .05). For the categories of color and blood vessel discrimination, the 3-chip camera scored significantly better than the HD camera (p < .05). For magnification alone, observers rated the 42-inch monitor statistically better than the 10-inch monitor. The expense of new medical technology must be judged against its added value. This study suggests that HD laryngeal imaging may not add significant value over currently available video systems, in perceived image quality, when a small monitor is used. Although differences in clarity between standard and HD cameras may not be readily apparent on small displays, a large display size coupled with HD technology may impart improved diagnosis of subtle vocal fold lesions and vibratory anomalies.
An Overview of the HST Advanced Camera for Surveys' On-orbit Performance
NASA Astrophysics Data System (ADS)
Hartig, G. F.; Ford, H. C.; Illingworth, G. D.; Clampin, M.; Bohlin, R. C.; Cox, C.; Krist, J.; Sparks, W. B.; De Marchi, G.; Martel, A. R.; McCann, W. J.; Meurer, G. R.; Sirianni, M.; Tsvetanov, Z.; Bartko, F.; Lindler, D. J.
2002-05-01
The Advanced Camera for Surveys (ACS) was installed in the HST on 7 March 2002 during the fourth servicing mission to the observatory, and is now beginning science operations. The ACS provides HST observers with a considerably more sensitive, higher-resolution camera with wider field and polarimetric, coronagraphic, low-resolution spectrographic and solar-blind FUV capabilities. We review selected results of the early verification and calibration program, comparing the achieved performance with the advertised specifications. Emphasis is placed on the optical characteristics of the camera, including image quality, throughput, geometric distortion and stray-light performance. More detailed analyses of various aspects of the ACS performance are presented in other papers at this meeting. This work was supported by a NASA contract and a NASA grant.
Rogers, B.T. Jr.; Davis, W.C.
1957-12-17
This patent relates to high speed cameras having resolution times of less than one-tenth microseconds suitable for filming distinct sequences of a very fast event such as an explosion. This camera consists of a rotating mirror with reflecting surfaces on both sides, a narrow mirror acting as a slit in a focal plane shutter, various other mirror and lens systems as well as an innage recording surface. The combination of the rotating mirrors and the slit mirror causes discrete, narrow, separate pictures to fall upon the film plane, thereby forming a moving image increment of the photographed event. Placing a reflecting surface on each side of the rotating mirror cancels the image velocity that one side of the rotating mirror would impart, so as a camera having this short a resolution time is thereby possible.
Keleshis, C; Ionita, CN; Yadava, G; Patel, V; Bednarek, DR; Hoffmann, KR; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873) PMID:18836570
Keleshis, C; Ionita, Cn; Yadava, G; Patel, V; Bednarek, Dr; Hoffmann, Kr; Verevkin, A; Rudin, S
2008-01-01
A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873).
Employing unmanned aerial vehicle to monitor the health condition of wind turbines
NASA Astrophysics Data System (ADS)
Huang, Yishuo; Chiang, Chih-Hung; Hsu, Keng-Tsang; Cheng, Chia-Chi
2018-04-01
Unmanned aerial vehicle (UAV) can gather the spatial information of huge structures, such as wind turbines, that can be difficult to obtain with traditional approaches. In this paper, the UAV used in the experiments is equipped with high resolution camera and thermal infrared camera. The high resolution camera can provide a series of images with resolution up to 10 Megapixels. Those images can be used to form the 3D model using the digital photogrammetry technique. By comparing the 3D scenes of the same wind turbine at different times, possible displacement of the supporting tower of the wind turbine, caused by ground movement or foundation deterioration may be determined. The recorded thermal images are analyzed by applying the image segmentation methods to the surface temperature distribution. A series of sub-regions are separated by the differences of the surface temperature. The high-resolution optical image and the segmented thermal image are fused such that the surface anomalies are more easily identified for wind turbines.
Measuring the spatial resolution of an optical system in an undergraduate optics laboratory
NASA Astrophysics Data System (ADS)
Leung, Calvin; Donnelly, T. D.
2017-06-01
Two methods of quantifying the spatial resolution of a camera are described, performed, and compared, with the objective of designing an imaging-system experiment for students in an undergraduate optics laboratory. With the goal of characterizing the resolution of a typical digital single-lens reflex (DSLR) camera, we motivate, introduce, and show agreement between traditional test-target contrast measurements and the technique of using Fourier analysis to obtain the modulation transfer function (MTF). The advantages and drawbacks of each method are compared. Finally, we explore the rich optical physics at work in the camera system by calculating the MTF as a function of wavelength and f-number. For example, we find that the Canon 40D demonstrates better spatial resolution at short wavelengths, in accordance with scalar diffraction theory, but is not diffraction-limited, being significantly affected by spherical aberration. The experiment and data analysis routines described here can be built and written in an undergraduate optics lab setting.
A filter spectrometer concept for facsimile cameras
NASA Technical Reports Server (NTRS)
Jobson, D. J.; Kelly, W. L., IV; Wall, S. D.
1974-01-01
A concept which utilizes interference filters and photodetector arrays to integrate spectrometry with the basic imagery function of a facsimile camera is described and analyzed. The analysis considers spectral resolution, instantaneous field of view, spectral range, and signal-to-noise ratio. Specific performance predictions for the Martian environment, the Viking facsimile camera design parameters, and a signal-to-noise ratio for each spectral band equal to or greater than 256 indicate the feasibility of obtaining a spectral resolution of 0.01 micrometers with an instantaneous field of view of about 0.1 deg in the 0.425 micrometers to 1.025 micrometers range using silicon photodetectors. A spectral resolution of 0.05 micrometers with an instantaneous field of view of about 0.6 deg in the 1.0 to 2.7 micrometers range using lead sulfide photodetectors is also feasible.
NASA Astrophysics Data System (ADS)
Kimm, H.; Guan, K.; Luo, Y.; Peng, J.; Mascaro, J.; Peng, B.
2017-12-01
Monitoring crop growth conditions is of primary interest to crop yield forecasting, food production assessment, and risk management of individual farmers and agribusiness. Despite its importance, there are limited access to field level crop growth/condition information in the public domain. This scarcity of ground truth data also hampers the use of satellite remote sensing for crop monitoring due to the lack of validation. Here, we introduce a new camera network (CropInsight) to monitor crop phenology, growth, and conditions that are designed for the US Corn Belt landscape. Specifically, this network currently includes 40 sites (20 corn and 20 soybean fields) across southern half of the Champaign County, IL ( 800 km2). Its wide distribution and automatic operation enable the network to capture spatiotemporal variations of crop growth condition continuously at the regional scale. At each site, low-maintenance, and high-resolution RGB digital cameras are set up having a downward view from 4.5 m height to take continuous images. In this study, we will use these images and novel satellite data to construct daily LAI map of the Champaign County at 30 m spatial resolution. First, we will estimate LAI from the camera images and evaluate it using the LAI data collected from LAI-2200 (LI-COR, Lincoln, NE). Second, we will develop relationships between the camera-based LAI estimation and vegetation indices derived from a newly developed MODIS-Landsat fusion product (daily, 30 m resolution, RGB + NIR + SWIR bands) and the Planet Lab's high-resolution satellite data (daily, 5 meter, RGB). Finally, we will scale up the above relationships to generate high spatiotemporal resolution crop LAI map for the whole Champaign County. The proposed work has potentials to expand to other agro-ecosystems and to the broader US Corn Belt.
Multiple-aperture optical design for micro-level cameras using 3D-printing method
NASA Astrophysics Data System (ADS)
Peng, Wei-Jei; Hsu, Wei-Yao; Cheng, Yuan-Chieh; Lin, Wen-Lung; Yu, Zong-Ru; Chou, Hsiao-Yu; Chen, Fong-Zhi; Fu, Chien-Chung; Wu, Chong-Syuan; Huang, Chao-Tsung
2018-02-01
The design of the ultra miniaturized camera using 3D-printing technology directly printed on to the complementary metal-oxide semiconductor (CMOS) imaging sensor is presented in this paper. The 3D printed micro-optics is manufactured using the femtosecond two-photon direct laser writing, and the figure error which could achieve submicron accuracy is suitable for the optical system. Because the size of the micro-level camera is approximately several hundreds of micrometers, the resolution is reduced much and highly limited by the Nyquist frequency of the pixel pitch. For improving the reduced resolution, one single-lens can be replaced by multiple-aperture lenses with dissimilar field of view (FOV), and then stitching sub-images with different FOV can achieve a high resolution within the central region of the image. The reason is that the angular resolution of the lens with smaller FOV is higher than that with larger FOV, and then the angular resolution of the central area can be several times than that of the outer area after stitching. For the same image circle, the image quality of the central area of the multi-lens system is significantly superior to that of a single-lens. The foveated image using stitching FOV breaks the limitation of the resolution for the ultra miniaturized imaging system, and then it can be applied such as biomedical endoscopy, optical sensing, and machine vision, et al. In this study, the ultra miniaturized camera with multi-aperture optics is designed and simulated for the optimum optical performance.
Optimal design and critical analysis of a high resolution video plenoptic demonstrator
NASA Astrophysics Data System (ADS)
Drazic, Valter; Sacré, Jean-Jacques; Bertrand, Jérôme; Schubert, Arno; Blondé, Etienne
2011-03-01
A plenoptic camera is a natural multi-view acquisition device also capable of measuring distances by correlating a set of images acquired under different parallaxes. Its single lens and single sensor architecture have two downsides: limited resolution and depth sensitivity. In a very first step and in order to circumvent those shortcomings, we have investigated how the basic design parameters of a plenoptic camera optimize both the resolution of each view and also its depth measuring capability. In a second step, we built a prototype based on a very high resolution Red One® movie camera with an external plenoptic adapter and a relay lens. The prototype delivered 5 video views of 820x410. The main limitation in our prototype is view cross talk due to optical aberrations which reduce the depth accuracy performance. We have simulated some limiting optical aberrations and predicted its impact on the performances of the camera. In addition, we developed adjustment protocols based on a simple pattern and analyzing programs which investigate the view mapping and amount of parallax crosstalk on the sensor on a pixel basis. The results of these developments enabled us to adjust the lenslet array with a sub micrometer precision and to mark the pixels of the sensor where the views do not register properly.
Optimal design and critical analysis of a high-resolution video plenoptic demonstrator
NASA Astrophysics Data System (ADS)
Drazic, Valter; Sacré, Jean-Jacques; Schubert, Arno; Bertrand, Jérôme; Blondé, Etienne
2012-01-01
A plenoptic camera is a natural multiview acquisition device also capable of measuring distances by correlating a set of images acquired under different parallaxes. Its single lens and single sensor architecture have two downsides: limited resolution and limited depth sensitivity. As a first step and in order to circumvent those shortcomings, we investigated how the basic design parameters of a plenoptic camera optimize both the resolution of each view and its depth-measuring capability. In a second step, we built a prototype based on a very high resolution Red One® movie camera with an external plenoptic adapter and a relay lens. The prototype delivered five video views of 820 × 410. The main limitation in our prototype is view crosstalk due to optical aberrations that reduce the depth accuracy performance. We simulated some limiting optical aberrations and predicted their impact on the performance of the camera. In addition, we developed adjustment protocols based on a simple pattern and analysis of programs that investigated the view mapping and amount of parallax crosstalk on the sensor on a pixel basis. The results of these developments enabled us to adjust the lenslet array with a submicrometer precision and to mark the pixels of the sensor where the views do not register properly.
Temperature resolution enhancing of commercially available IR camera using computer processing
NASA Astrophysics Data System (ADS)
Trofimov, Vyacheslav A.; Trofimov, Vladislav V.
2015-09-01
As it is well-known, application of the passive THz camera for the security problems is very promising way. It allows seeing concealed object without contact with a person and this camera is non-dangerous for a person. Using such THz camera, one can see a temperature difference on the human skin if this difference is caused by different temperatures inside the body. Because the passive THz camera is very expensive, we try to use the IR camera for observing of such phenomenon. We use a computer code that is available for treatment of the images captured by commercially available IR camera, manufactured by Flir Corp. Using this code we demonstrate clearly changing of human body skin temperature induced by water drinking. Nevertheless, in some cases it is necessary to use additional computer processing to show clearly changing of human body temperature. One of these approaches is developed by us. We believe that we increase ten times (or more) the temperature resolution of such camera. Carried out experiments can be used for solving the counter-terrorism problem and for medicine problems solving. Shown phenomenon is very important for the detection of forbidden objects and substances concealed inside the human body using non-destructive control without X-ray application. Early we have demonstrated such possibility using THz radiation.
Can light-field photography ease focusing on the scalp and oral cavity?
Taheri, Arash; Feldman, Steven R
2013-08-01
Capturing a well-focused image using an autofocus camera can be difficult in oral cavity and on a hairy scalp. Light-field digital cameras capture data regarding the color, intensity, and direction of rays of light. Having information regarding direction of rays of light, computer software can be used to focus on different subjects in the field after the image data have been captured. A light-field camera was used to capture the images of the scalp and oral cavity. The related computer software was used to focus on scalp or different parts of oral cavity. The final pictures were compared with pictures taken with conventional, compact, digital cameras. The camera worked well for oral cavity. It also captured the pictures of scalp easily; however, we had to repeat clicking between the hairs on different points to choose the scalp for focusing. A major drawback of the system was the resolution of the resulting pictures that was lower than conventional digital cameras. Light-field digital cameras are fast and easy to use. They can capture more information on the full depth of field compared with conventional cameras. However, the resolution of the pictures is relatively low. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Advances in Gamma-Ray Imaging with Intensified Quantum-Imaging Detectors
NASA Astrophysics Data System (ADS)
Han, Ling
Nuclear medicine, an important branch of modern medical imaging, is an essential tool for both diagnosis and treatment of disease. As the fundamental element of nuclear medicine imaging, the gamma camera is able to detect gamma-ray photons emitted by radiotracers injected into a patient and form an image of the radiotracer distribution, reflecting biological functions of organs or tissues. Recently, an intensified CCD/CMOS-based quantum detector, called iQID, was developed in the Center for Gamma-Ray Imaging. Originally designed as a novel type of gamma camera, iQID demonstrated ultra-high spatial resolution (< 100 micron) and many other advantages over traditional gamma cameras. This work focuses on advancing this conceptually-proven gamma-ray imaging technology to make it ready for both preclinical and clinical applications. To start with, a Monte Carlo simulation of the key light-intensification device, i.e. the image intensifier, was developed, which revealed the dominating factor(s) that limit energy resolution performance of the iQID cameras. For preclinical imaging applications, a previously-developed iQID-based single-photon-emission computed-tomography (SPECT) system, called FastSPECT III, was fully advanced in terms of data acquisition software, system sensitivity and effective FOV by developing and adopting a new photon-counting algorithm, thicker columnar scintillation detectors, and system calibration method. Originally designed for mouse brain imaging, the system is now able to provide full-body mouse imaging with sub-350-micron spatial resolution. To further advance the iQID technology to include clinical imaging applications, a novel large-area iQID gamma camera, called LA-iQID, was developed from concept to prototype. Sub-mm system resolution in an effective FOV of 188 mm x 188 mm has been achieved. The camera architecture, system components, design and integration, data acquisition, camera calibration, and performance evaluation are presented in this work. Mounted on a castered counter-weighted clinical cart, the camera also features portable and mobile capabilities for easy handling and on-site applications at remote locations where hospital facilities are not available.
Lin, Le; Wang, Ying; Liu, Tianxue
2017-01-01
Much of the literature on recovery focuses on the economy, the physical environment and infrastructure at a macro level, which may ignore the personal experiences of affected individuals during recovery. This paper combines internal factors at a micro level and external factors at a macro level to model for understanding perception of recovery (PoR). This study focuses on areas devastated by the 2008 Wenchuan earthquake in China. With respect to three recovery-related aspects (house recovery condition (HRC), family recovery power (FRP) and reconstruction investment (RI)), structural equation modeling (SEM) was applied. It was found that the three aspects (FRP, HRC and RI) effectively explain how earthquake affected households perceive recovery. Internal factors associated with FRP contributed the most to favourable PoR, followed by external factors associated with HRC. Findings identified that for PoR the importance of active recovery within households outweighed an advantageous house recovery condition. At the same time, households trapped in unfavourable external conditions would invest more in housing recovery, which result in wealth accumulation and improved quality of life leading to a high level of PoR. In addition, schooling in households showed a negative effect on improving PoR. This research contributes to current debates around post-disaster permanent housing policy. It is implied that a one-size-fits-all policy in disaster recovery may not be effective and more specific assistance should be provided to those people in need. PMID:28854217
USDA-ARS?s Scientific Manuscript database
Consumer-grade cameras are being increasingly used for remote sensing applications in recent years. However, the performance of this type of cameras has not been systematically tested and well documented in the literature. The objective of this research was to evaluate the performance of original an...
Developments in mercuric iodide gamma ray imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patt, B.E.; Beyerle, A.G.; Dolin, R.C.
A mercuric iodide gamma-ray imaging array and camera system previously described has been characterized for spatial and energy resolution. Based on this data a new camera is being developed to more fully exploit the potential of the array. Characterization results and design criterion for the new camera will be presented. 2 refs., 7 figs.
NASA Astrophysics Data System (ADS)
Williams, B. P.; Kjellstrand, B.; Jones, G.; Reimuller, J. D.; Fritts, D. C.; Miller, A.; Geach, C.; Limon, M.; Hanany, S.; Kaifler, B.; Wang, L.; Taylor, M. J.
2017-12-01
PMC-Turbo is a NASA long-duration, high-altitude balloon mission that will deploy 7 high-resolution cameras to image polar mesospheric clouds (PMC) and measure gravity wave breakdown and turbulence. The mission has been enhanced by the addition of the DLR Balloon Lidar Experiment (BOLIDE) and an OH imager from Utah State University. This instrument suite will provide high horizontal and vertical resolution of the wave-modified PMC structure along a several thousand kilometer flight track. We have requested a flight from Kiruna, Sweden to Canada in June 2017 or McMurdo Base, Antarctica in Dec 2017. Three of the PMC camera systems were deployed on an aircraft and two tomographic ground sites for the High Level campaign in Canada in June/July 2017. On several nights the cameras observed PMC's with strong gravity wave breaking signatures. One PMC camera will piggyback on the Super Tiger mission scheduled to be launched in Dec 2017 from McMurdo, so we will obtain PMC images and wave/turbulence data from both the northern and southern hemispheres.
Barrier Coverage for 3D Camera Sensor Networks
Wu, Chengdong; Zhang, Yunzhou; Jia, Zixi; Ji, Peng; Chu, Hao
2017-01-01
Barrier coverage, an important research area with respect to camera sensor networks, consists of a number of camera sensors to detect intruders that pass through the barrier area. Existing works on barrier coverage such as local face-view barrier coverage and full-view barrier coverage typically assume that each intruder is considered as a point. However, the crucial feature (e.g., size) of the intruder should be taken into account in the real-world applications. In this paper, we propose a realistic resolution criterion based on a three-dimensional (3D) sensing model of a camera sensor for capturing the intruder’s face. Based on the new resolution criterion, we study the barrier coverage of a feasible deployment strategy in camera sensor networks. Performance results demonstrate that our barrier coverage with more practical considerations is capable of providing a desirable surveillance level. Moreover, compared with local face-view barrier coverage and full-view barrier coverage, our barrier coverage is more reasonable and closer to reality. To the best of our knowledge, our work is the first to propose barrier coverage for 3D camera sensor networks. PMID:28771167
Barrier Coverage for 3D Camera Sensor Networks.
Si, Pengju; Wu, Chengdong; Zhang, Yunzhou; Jia, Zixi; Ji, Peng; Chu, Hao
2017-08-03
Barrier coverage, an important research area with respect to camera sensor networks, consists of a number of camera sensors to detect intruders that pass through the barrier area. Existing works on barrier coverage such as local face-view barrier coverage and full-view barrier coverage typically assume that each intruder is considered as a point. However, the crucial feature (e.g., size) of the intruder should be taken into account in the real-world applications. In this paper, we propose a realistic resolution criterion based on a three-dimensional (3D) sensing model of a camera sensor for capturing the intruder's face. Based on the new resolution criterion, we study the barrier coverage of a feasible deployment strategy in camera sensor networks. Performance results demonstrate that our barrier coverage with more practical considerations is capable of providing a desirable surveillance level. Moreover, compared with local face-view barrier coverage and full-view barrier coverage, our barrier coverage is more reasonable and closer to reality. To the best of our knowledge, our work is the first to propose barrier coverage for 3D camera sensor networks.
Applying compressive sensing to TEM video: A substantial frame rate increase on any camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, Andrew; Kovarik, Libor; Abellan, Patricia
One of the main limitations of imaging at high spatial and temporal resolution during in-situ transmission electron microscopy (TEM) experiments is the frame rate of the camera being used to image the dynamic process. While the recent development of direct detectors has provided the hardware to achieve frame rates approaching 0.1 ms, the cameras are expensive and must replace existing detectors. In this paper, we examine the use of coded aperture compressive sensing (CS) methods to increase the frame rate of any camera with simple, low-cost hardware modifications. The coded aperture approach allows multiple sub-frames to be coded and integratedmore » into a single camera frame during the acquisition process, and then extracted upon readout using statistical CS inversion. Here we describe the background of CS and statistical methods in depth and simulate the frame rates and efficiencies for in-situ TEM experiments. Depending on the resolution and signal/noise of the image, it should be possible to increase the speed of any camera by more than an order of magnitude using this approach.« less
Applying compressive sensing to TEM video: A substantial frame rate increase on any camera
Stevens, Andrew; Kovarik, Libor; Abellan, Patricia; ...
2015-08-13
One of the main limitations of imaging at high spatial and temporal resolution during in-situ transmission electron microscopy (TEM) experiments is the frame rate of the camera being used to image the dynamic process. While the recent development of direct detectors has provided the hardware to achieve frame rates approaching 0.1 ms, the cameras are expensive and must replace existing detectors. In this paper, we examine the use of coded aperture compressive sensing (CS) methods to increase the frame rate of any camera with simple, low-cost hardware modifications. The coded aperture approach allows multiple sub-frames to be coded and integratedmore » into a single camera frame during the acquisition process, and then extracted upon readout using statistical CS inversion. Here we describe the background of CS and statistical methods in depth and simulate the frame rates and efficiencies for in-situ TEM experiments. Depending on the resolution and signal/noise of the image, it should be possible to increase the speed of any camera by more than an order of magnitude using this approach.« less
Neuromorphic Event-Based 3D Pose Estimation
Reverter Valeiras, David; Orchard, Garrick; Ieng, Sio-Hoi; Benosman, Ryad B.
2016-01-01
Pose estimation is a fundamental step in many artificial vision tasks. It consists of estimating the 3D pose of an object with respect to a camera from the object's 2D projection. Current state of the art implementations operate on images. These implementations are computationally expensive, especially for real-time applications. Scenes with fast dynamics exceeding 30–60 Hz can rarely be processed in real-time using conventional hardware. This paper presents a new method for event-based 3D object pose estimation, making full use of the high temporal resolution (1 μs) of asynchronous visual events output from a single neuromorphic camera. Given an initial estimate of the pose, each incoming event is used to update the pose by combining both 3D and 2D criteria. We show that the asynchronous high temporal resolution of the neuromorphic camera allows us to solve the problem in an incremental manner, achieving real-time performance at an update rate of several hundreds kHz on a conventional laptop. We show that the high temporal resolution of neuromorphic cameras is a key feature for performing accurate pose estimation. Experiments are provided showing the performance of the algorithm on real data, including fast moving objects, occlusions, and cases where the neuromorphic camera and the object are both in motion. PMID:26834547
Underwater video enhancement using multi-camera super-resolution
NASA Astrophysics Data System (ADS)
Quevedo, E.; Delory, E.; Callicó, G. M.; Tobajas, F.; Sarmiento, R.
2017-12-01
Image spatial resolution is critical in several fields such as medicine, communications or satellite, and underwater applications. While a large variety of techniques for image restoration and enhancement has been proposed in the literature, this paper focuses on a novel Super-Resolution fusion algorithm based on a Multi-Camera environment that permits to enhance the quality of underwater video sequences without significantly increasing computation. In order to compare the quality enhancement, two objective quality metrics have been used: PSNR (Peak Signal-to-Noise Ratio) and the SSIM (Structural SIMilarity) index. Results have shown that the proposed method enhances the objective quality of several underwater sequences, avoiding the appearance of undesirable artifacts, with respect to basic fusion Super-Resolution algorithms.
Babcock, Hazen P
2018-01-29
This work explores the use of industrial grade CMOS cameras for single molecule localization microscopy (SMLM). We show that industrial grade CMOS cameras approach the performance of scientific grade CMOS cameras at a fraction of the cost. This makes it more economically feasible to construct high-performance imaging systems with multiple cameras that are capable of a diversity of applications. In particular we demonstrate the use of industrial CMOS cameras for biplane, multiplane and spectrally resolved SMLM. We also provide open-source software for simultaneous control of multiple CMOS cameras and for the reduction of the movies that are acquired to super-resolution images.
Lytro camera technology: theory, algorithms, performance analysis
NASA Astrophysics Data System (ADS)
Georgiev, Todor; Yu, Zhan; Lumsdaine, Andrew; Goma, Sergio
2013-03-01
The Lytro camera is the first implementation of a plenoptic camera for the consumer market. We consider it a successful example of the miniaturization aided by the increase in computational power characterizing mobile computational photography. The plenoptic camera approach to radiance capture uses a microlens array as an imaging system focused on the focal plane of the main camera lens. This paper analyzes the performance of Lytro camera from a system level perspective, considering the Lytro camera as a black box, and uses our interpretation of Lytro image data saved by the camera. We present our findings based on our interpretation of Lytro camera file structure, image calibration and image rendering; in this context, artifacts and final image resolution are discussed.
NASA Astrophysics Data System (ADS)
Sun, Jiwen; Wei, Ling; Fu, Danying
2002-01-01
resolution and wide swath. In order to assure its high optical precision smoothly passing the rigorous dynamic load of launch, it should be of high structural rigidity. Therefore, a careful study of the dynamic features of the camera structure should be performed. Pro/E. An interference examination is performed on the precise CAD model of the camera for mending the structural design. for the first time in China, and the analysis of structural dynamic of the camera is accomplished by applying the structural analysis code PATRAN and NASTRAN. The main research programs include: 1) the comparative calculation of modes analysis of the critical structure of the camera is achieved by using 4 nodes and 10 nodes tetrahedral elements respectively, so as to confirm the most reasonable general model; 2) through the modes analysis of the camera from several cases, the inherent frequencies and modes are obtained and further the rationality of the structural design of the camera is proved; 3) the static analysis of the camera under self gravity and overloads is completed and the relevant deformation and stress distributions are gained; 4) the response calculation of sine vibration of the camera is completed and the corresponding response curve and maximum acceleration response with corresponding frequencies are obtained. software technique is accurate and efficient. sensitivity, the dynamic design and engineering optimization of the critical structure of the camera are discussed. fundamental technology in design of forecoming space optical instruments.
High-resolution hyperspectral ground mapping for robotic vision
NASA Astrophysics Data System (ADS)
Neuhaus, Frank; Fuchs, Christian; Paulus, Dietrich
2018-04-01
Recently released hyperspectral cameras use large, mosaiced filter patterns to capture different ranges of the light's spectrum in each of the camera's pixels. Spectral information is sparse, as it is not fully available in each location. We propose an online method that avoids explicit demosaicing of camera images by fusing raw, unprocessed, hyperspectral camera frames inside an ego-centric ground surface map. It is represented as a multilayer heightmap data structure, whose geometry is estimated by combining a visual odometry system with either dense 3D reconstruction or 3D laser data. We use a publicly available dataset to show that our approach is capable of constructing an accurate hyperspectral representation of the surface surrounding the vehicle. We show that in many cases our approach increases spatial resolution over a demosaicing approach, while providing the same amount of spectral information.
Depth Perception In Remote Stereoscopic Viewing Systems
NASA Technical Reports Server (NTRS)
Diner, Daniel B.; Von Sydow, Marika
1989-01-01
Report describes theoretical and experimental studies of perception of depth by human operators through stereoscopic video systems. Purpose of such studies to optimize dual-camera configurations used to view workspaces of remote manipulators at distances of 1 to 3 m from cameras. According to analysis, static stereoscopic depth distortion decreased, without decreasing stereoscopitc depth resolution, by increasing camera-to-object and intercamera distances and camera focal length. Further predicts dynamic stereoscopic depth distortion reduced by rotating cameras around center of circle passing through point of convergence of viewing axes and first nodal points of two camera lenses.
Speckle imaging for planetary research
NASA Technical Reports Server (NTRS)
Nisenson, P.; Goody, R.; Apt, J.; Papaliolios, C.
1983-01-01
The present study of speckle imaging technique effectiveness encompasses image reconstruction by means of a division algorithm for Fourier amplitudes, and the Knox-Thompson (1974) algorithm for Fourier phases. Results which have been obtained for Io, Titan, Pallas, Jupiter and Uranus indicate that spatial resolutions lower than the seeing limit by a factor of four are obtainable for objects brighter than Uranus. The resolutions obtained are well above the diffraction limit, due to inadequacies of the video camera employed. A photon-counting camera has been developed to overcome these difficulties, making possible the diffraction-limited resolution of objects as faint as Charon.
A novel SPECT camera for molecular imaging of the prostate
NASA Astrophysics Data System (ADS)
Cebula, Alan; Gilland, David; Su, Li-Ming; Wagenaar, Douglas; Bahadori, Amir
2011-10-01
The objective of this work is to develop an improved SPECT camera for dedicated prostate imaging. Complementing the recent advancements in agents for molecular prostate imaging, this device has the potential to assist in distinguishing benign from aggressive cancers, to improve site-specific localization of cancer, to improve accuracy of needle-guided prostate biopsy of cancer sites, and to aid in focal therapy procedures such as cryotherapy and radiation. Theoretical calculations show that the spatial resolution/detection sensitivity of the proposed SPECT camera can rival or exceed 3D PET and further signal-to-noise advantage is attained with the better energy resolution of the CZT modules. Based on photon transport simulation studies, the system has a reconstructed spatial resolution of 4.8 mm with a sensitivity of 0.0001. Reconstruction of a simulated prostate distribution demonstrates the focal imaging capability of the system.
Thermal infrared panoramic imaging sensor
NASA Astrophysics Data System (ADS)
Gutin, Mikhail; Tsui, Eddy K.; Gutin, Olga; Wang, Xu-Ming; Gutin, Alexey
2006-05-01
Panoramic cameras offer true real-time, 360-degree coverage of the surrounding area, valuable for a variety of defense and security applications, including force protection, asset protection, asset control, security including port security, perimeter security, video surveillance, border control, airport security, coastguard operations, search and rescue, intrusion detection, and many others. Automatic detection, location, and tracking of targets outside protected area ensures maximum protection and at the same time reduces the workload on personnel, increases reliability and confidence of target detection, and enables both man-in-the-loop and fully automated system operation. Thermal imaging provides the benefits of all-weather, 24-hour day/night operation with no downtime. In addition, thermal signatures of different target types facilitate better classification, beyond the limits set by camera's spatial resolution. The useful range of catadioptric panoramic cameras is affected by their limited resolution. In many existing systems the resolution is optics-limited. Reflectors customarily used in catadioptric imagers introduce aberrations that may become significant at large camera apertures, such as required in low-light and thermal imaging. Advantages of panoramic imagers with high image resolution include increased area coverage with fewer cameras, instantaneous full horizon detection, location and tracking of multiple targets simultaneously, extended range, and others. The Automatic Panoramic Thermal Integrated Sensor (APTIS), being jointly developed by Applied Science Innovative, Inc. (ASI) and the Armament Research, Development and Engineering Center (ARDEC) combines the strengths of improved, high-resolution panoramic optics with thermal imaging in the 8 - 14 micron spectral range, leveraged by intelligent video processing for automated detection, location, and tracking of moving targets. The work in progress supports the Future Combat Systems (FCS) and the Intelligent Munitions Systems (IMS). The APTIS is anticipated to operate as an intelligent node in a wireless network of multifunctional nodes that work together to serve in a wide range of applications of homeland security, as well as serve the Army in tasks of improved situational awareness (SA) in defense and offensive operations, and as a sensor node in tactical Intelligence Surveillance Reconnaissance (ISR). The novel ViperView TM high-resolution panoramic thermal imager is the heart of the APTIS system. It features an aberration-corrected omnidirectional imager with small optics designed to match the resolution of a 640x480 pixels IR camera with improved image quality for longer range target detection, classification, and tracking. The same approach is applicable to panoramic cameras working in the visible spectral range. Other components of the ATPIS system include network communications, advanced power management, and wakeup capability. Recent developments include image processing, optical design being expanded into the visible spectral range, and wireless communications design. This paper describes the development status of the APTIS system.
Compact full-motion video hyperspectral cameras: development, image processing, and applications
NASA Astrophysics Data System (ADS)
Kanaev, A. V.
2015-10-01
Emergence of spectral pixel-level color filters has enabled development of hyper-spectral Full Motion Video (FMV) sensors operating in visible (EO) and infrared (IR) wavelengths. The new class of hyper-spectral cameras opens broad possibilities of its utilization for military and industry purposes. Indeed, such cameras are able to classify materials as well as detect and track spectral signatures continuously in real time while simultaneously providing an operator the benefit of enhanced-discrimination-color video. Supporting these extensive capabilities requires significant computational processing of the collected spectral data. In general, two processing streams are envisioned for mosaic array cameras. The first is spectral computation that provides essential spectral content analysis e.g. detection or classification. The second is presentation of the video to an operator that can offer the best display of the content depending on the performed task e.g. providing spatial resolution enhancement or color coding of the spectral analysis. These processing streams can be executed in parallel or they can utilize each other's results. The spectral analysis algorithms have been developed extensively, however demosaicking of more than three equally-sampled spectral bands has been explored scarcely. We present unique approach to demosaicking based on multi-band super-resolution and show the trade-off between spatial resolution and spectral content. Using imagery collected with developed 9-band SWIR camera we demonstrate several of its concepts of operation including detection and tracking. We also compare the demosaicking results to the results of multi-frame super-resolution as well as to the combined multi-frame and multiband processing.
HST Solar Arrays photographed by Electronic Still Camera
NASA Technical Reports Server (NTRS)
1993-01-01
This close-up view of one of two Solar Arrays (SA) on the Hubble Space Telescope (HST) was photographed with an Electronic Still Camera (ESC), and downlinked to ground controllers soon afterward. Electronic still photography is a technology which provides the means for a handheld camera to electronically capture and digitize an image with resolution approaching film quality.
Noise and sensitivity of x-ray framing cameras at Nike (abstract)
NASA Astrophysics Data System (ADS)
Pawley, C. J.; Deniz, A. V.; Lehecka, T.
1999-01-01
X-ray framing cameras are the most widely used tool for radiographing density distributions in laser and Z-pinch driven experiments. The x-ray framing cameras that were developed specifically for experiments on the Nike laser system are described. One of these cameras has been coupled to a CCD camera and was tested for resolution and image noise using both electrons and x rays. The largest source of noise in the images was found to be due to low quantum detection efficiency of x-ray photons.
1920x1080 pixel color camera with progressive scan at 50 to 60 frames per second
NASA Astrophysics Data System (ADS)
Glenn, William E.; Marcinka, John W.
1998-09-01
For over a decade, the broadcast industry, the film industry and the computer industry have had a long-range objective to originate high definition images with progressive scan. This produces images with better vertical resolution and much fewer artifacts than interlaced scan. Computers almost universally use progressive scan. The broadcast industry has resisted switching from interlace to progressive because no cameras were available in that format with the 1920 X 1080 resolution that had obtained international acceptance for high definition program production. The camera described in this paper produces an output in that format derived from two 1920 X 1080 CCD sensors produced by Eastman Kodak.
Mini gamma camera, camera system and method of use
Majewski, Stanislaw; Weisenberger, Andrew G.; Wojcik, Randolph F.
2001-01-01
A gamma camera comprising essentially and in order from the front outer or gamma ray impinging surface: 1) a collimator, 2) a scintillator layer, 3) a light guide, 4) an array of position sensitive, high resolution photomultiplier tubes, and 5) printed circuitry for receipt of the output of the photomultipliers. There is also described, a system wherein the output supplied by the high resolution, position sensitive photomultipiler tubes is communicated to: a) a digitizer and b) a computer where it is processed using advanced image processing techniques and a specific algorithm to calculate the center of gravity of any abnormality observed during imaging, and c) optional image display and telecommunications ports.
Wong, Wai-Hoi; Li, Hongdi; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio A; Liu, Shitao; Wang, Chao; An, Shaohui
2012-11-01
The dedicated murine PET (MuPET) scanner is a high-resolution, high-sensitivity, and low-cost preclinical PET camera designed and manufactured at our laboratory. In this article, we report its performance according to the NU 4-2008 standards of the National Electrical Manufacturers Association (NEMA). We also report the results of additional phantom and mouse studies. The MuPET scanner, which is integrated with a CT camera, is based on the photomultiplier-quadrant-sharing concept and comprises 180 blocks of 13 × 13 lutetium yttrium oxyorthosilicate crystals (1.24 × 1.4 × 9.5 mm(3)) and 210 low-cost 19-mm photomultipliers. The camera has 78 detector rings, with an 11.6-cm axial field of view and a ring diameter of 16.6 cm. We measured the energy resolution, scatter fraction, sensitivity, spatial resolution, and counting rate performance of the scanner. In addition, we scanned the NEMA image-quality phantom, Micro Deluxe and Ultra-Micro Hot Spot phantoms, and 2 healthy mice. The system average energy resolution was 14% at 511 keV. The average spatial resolution at the center of the field of view was about 1.2 mm, improving to 0.8 mm and remaining below 1.2 mm in the central 6-cm field of view when a resolution-recovery method was used. The absolute sensitivity of the camera was 6.38% for an energy window of 350-650 keV and a coincidence timing window of 3.4 ns. The system scatter fraction was 11.9% for the NEMA mouselike phantom and 28% for the ratlike phantom. The maximum noise-equivalent counting rate was 1,100 at 57 MBq for the mouselike phantom and 352 kcps at 65 MBq for the ratlike phantom. The 1-mm fillable rod was clearly observable using the NEMA image-quality phantom. The images of the Ultra-Micro Hot Spot phantom also showed the 1-mm hot rods. In the mouse studies, both the left and right ventricle walls were clearly observable, as were the Harderian glands. The MuPET camera has excellent resolution, sensitivity, counting rate, and imaging performance. The data show it is a powerful scanner for preclinical animal study and pharmaceutical development.
Experimental comparison of high-density scintillators for EMCCD-based gamma ray imaging
NASA Astrophysics Data System (ADS)
Heemskerk, Jan W. T.; Kreuger, Rob; Goorden, Marlies C.; Korevaar, Marc A. N.; Salvador, Samuel; Seeley, Zachary M.; Cherepy, Nerine J.; van der Kolk, Erik; Payne, Stephen A.; Dorenbos, Pieter; Beekman, Freek J.
2012-07-01
Detection of x-rays and gamma rays with high spatial resolution can be achieved with scintillators that are optically coupled to electron-multiplying charge-coupled devices (EMCCDs). These can be operated at typical frame rates of 50 Hz with low noise. In such a set-up, scintillation light within each frame is integrated after which the frame is analyzed for the presence of scintillation events. This method allows for the use of scintillator materials with relatively long decay times of a few milliseconds, not previously considered for use in photon-counting gamma cameras, opening up an unexplored range of dense scintillators. In this paper, we test CdWO4 and transparent polycrystalline ceramics of Lu2O3:Eu and (Gd,Lu)2O3:Eu as alternatives to currently used CsI:Tl in order to improve the performance of EMCCD-based gamma cameras. The tested scintillators were selected for their significantly larger cross-sections at 140 keV (99mTc) compared to CsI:Tl combined with moderate to good light yield. A performance comparison based on gamma camera spatial and energy resolution was done with all tested scintillators having equal (66%) interaction probability at 140 keV. CdWO4, Lu2O3:Eu and (Gd,Lu)2O3:Eu all result in a significantly improved spatial resolution over CsI:Tl, albeit at the cost of reduced energy resolution. Lu2O3:Eu transparent ceramic gives the best spatial resolution: 65 µm full-width-at-half-maximum (FWHM) compared to 147 µm FWHM for CsI:Tl. In conclusion, these ‘slow’ dense scintillators open up new possibilities for improving the spatial resolution of EMCCD-based scintillation cameras.
50 CFR 216.177 - Letters of Authorization.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MAMMALS Taking Marine Mammals Incidental to U.S. Navy Training in the Hawaii Range Complex (HRC) § 216.177... Authorization will be based on a determination that the total number of marine mammals taken by the activity as...
Orientation selectivity sharpens motion detection in Drosophila
Fisher, Yvette E.; Silies, Marion; Clandinin, Thomas R.
2015-01-01
SUMMARY Detecting the orientation and movement of edges in a scene is critical to visually guided behaviors of many animals. What are the circuit algorithms that allow the brain to extract such behaviorally vital visual cues? Using in vivo two-photon calcium imaging in Drosophila, we describe direction selective signals in the dendrites of T4 and T5 neurons, detectors of local motion. We demonstrate that this circuit performs selective amplification of local light inputs, an observation that constrains motion detection models and confirms a core prediction of the Hassenstein-Reichardt Correlator (HRC). These neurons are also orientation selective, responding strongly to static features that are orthogonal to their preferred axis of motion, a tuning property not predicted by the HRC. This coincident extraction of orientation and direction sharpens directional tuning through surround inhibition and reveals a striking parallel between visual processing in flies and vertebrate cortex, suggesting a universal strategy for motion processing. PMID:26456048
Resolution for color photography
NASA Astrophysics Data System (ADS)
Hubel, Paul M.; Bautsch, Markus
2006-02-01
Although it is well known that luminance resolution is most important, the ability to accurately render colored details, color textures, and colored fabrics cannot be overlooked. This includes the ability to accurately render single-pixel color details as well as avoiding color aliasing. All consumer digital cameras on the market today record in color and the scenes people are photographing are usually color. Yet almost all resolution measurements made on color cameras are done using a black and white target. In this paper we present several methods for measuring and quantifying color resolution. The first method, detailed in a previous publication, uses a slanted-edge target of two colored surfaces in place of the standard black and white edge pattern. The second method employs the standard black and white targets recommended in the ISO standard, but records these onto the camera through colored filters thus giving modulation between black and one particular color component; red, green, and blue color separation filters are used in this study. The third method, conducted at Stiftung Warentest, an independent consumer organization of Germany, uses a whitelight interferometer to generate fringe pattern targets of varying color and spatial frequency.
NASA Astrophysics Data System (ADS)
Breitfelder, Stefan; Reichel, Frank R.; Gaertner, Ernst; Hacker, Erich J.; Cappellaro, Markus; Rudolf, Peter; Voelk, Ute
1998-04-01
Digital cameras are of increasing significance for professional applications in photo studios where fashion, portrait, product and catalog photographs or advertising photos of high quality have to be taken. The eyelike is a digital camera system which has been developed for such applications. It is capable of working online with high frame rates and images of full sensor size and it provides a resolution that can be varied between 2048 by 2048 and 6144 by 6144 pixel at a RGB color depth of 12 Bit per channel with an also variable exposure time of 1/60s to 1s. With an exposure time of 100 ms digitization takes approx. 2 seconds for an image of 2048 by 2048 pixels (12 Mbyte), 8 seconds for the image of 4096 by 4096 pixels (48 Mbyte) and 40 seconds for the image of 6144 by 6144 pixels (108 MByte). The eyelike can be used in various configurations. Used as a camera body most commercial lenses can be connected to the camera via existing lens adaptors. On the other hand the eyelike can be used as a back to most commercial 4' by 5' view cameras. This paper describes the eyelike camera concept with the essential system components. The article finishes with a description of the software, which is needed to bring the high quality of the camera to the user.
Rover mast calibration, exact camera pointing, and camara handoff for visual target tracking
NASA Technical Reports Server (NTRS)
Kim, Won S.; Ansar, Adnan I.; Steele, Robert D.
2005-01-01
This paper presents three technical elements that we have developed to improve the accuracy of the visual target tracking for single-sol approach-and-instrument placement in future Mars rover missions. An accurate, straightforward method of rover mast calibration is achieved by using a total station, a camera calibration target, and four prism targets mounted on the rover. The method was applied to Rocky8 rover mast calibration and yielded a 1.1-pixel rms residual error. Camera pointing requires inverse kinematic solutions for mast pan and tilt angles such that the target image appears right at the center of the camera image. Two issues were raised. Mast camera frames are in general not parallel to the masthead base frame. Further, the optical axis of the camera model in general does not pass through the center of the image. Despite these issues, we managed to derive non-iterative closed-form exact solutions, which were verified with Matlab routines. Actual camera pointing experiments aver 50 random target image paints yielded less than 1.3-pixel rms pointing error. Finally, a purely geometric method for camera handoff using stereo views of the target has been developed. Experimental test runs show less than 2.5 pixels error on high-resolution Navcam for Pancam-to-Navcam handoff, and less than 4 pixels error on lower-resolution Hazcam for Navcam-to-Hazcam handoff.
First results from the TOPSAT camera
NASA Astrophysics Data System (ADS)
Greenway, Paul; Tosh, Ian; Morris, Nigel; Burton, Gary; Cawley, Steve
2017-11-01
The TopSat camera is a low cost remote sensing imager capable of producing 2.5 metre resolution panchromatic imagery, funded by the British National Space Centre's Mosaic programme. The instrument was designed and assembled at the Space Science & Technology Department of the CCLRC's Rutherford Appleton Laboratory (RAL) in the UK, and was launched on the 27th October 2005 from Plesetsk Cosmodrome in Northern Russia on a Kosmos-3M. The camera utilises an off-axis three mirror system, which has the advantages of excellent image quality over a wide field of view, combined with a compactness that makes its overall dimensions smaller than its focal length. Keeping the costs to a minimum has been a major design driver in the development of this camera. The camera is part of the TopSat mission, which is a collaboration between four UK organisations; QinetiQ, Surrey Satellite Technology Ltd (SSTL), RAL and Infoterra. Its objective is to demonstrate provision of rapid response high resolution imagery to fixed and mobile ground stations using a low cost minisatellite. The paper "Development of the TopSat Camera" presented by RAL at the 5th ICSO in 2004 described the opto-mechanical design, assembly, alignment and environmental test methods implemented. Now that the spacecraft is in orbit and successfully acquiring images, this paper presents the first results from the camera and makes an initial assessment of the camera's in-orbit performance.
Split ring resonator based THz-driven electron streak camera featuring femtosecond resolution
Fabiańska, Justyna; Kassier, Günther; Feurer, Thomas
2014-01-01
Through combined three-dimensional electromagnetic and particle tracking simulations we demonstrate a THz driven electron streak camera featuring a temporal resolution on the order of a femtosecond. The ultrafast streaking field is generated in a resonant THz sub-wavelength antenna which is illuminated by an intense single-cycle THz pulse. Since electron bunches and THz pulses are generated with parts of the same laser system, synchronization between the two is inherently guaranteed. PMID:25010060
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemaire, H.; Barat, E.; Carrel, F.
In this work, we tested Maximum likelihood expectation-maximization (MLEM) algorithms optimized for gamma imaging applications on two recent coded mask gamma cameras. We respectively took advantage of the characteristics of the GAMPIX and Caliste HD-based gamma cameras: noise reduction thanks to mask/anti-mask procedure but limited energy resolution for GAMPIX, high energy resolution for Caliste HD. One of our short-term perspectives is the test of MAPEM algorithms integrating specific prior values for the data to reconstruct adapted to the gamma imaging topic. (authors)
Cheng, Yufeng; Jin, Shuying; Wang, Mi; Zhu, Ying; Dong, Zhipeng
2017-06-20
The linear array push broom imaging mode is widely used for high resolution optical satellites (HROS). Using double-cameras attached by a high-rigidity support along with push broom imaging is one method to enlarge the field of view while ensuring high resolution. High accuracy image mosaicking is the key factor of the geometrical quality of complete stitched satellite imagery. This paper proposes a high accuracy image mosaicking approach based on the big virtual camera (BVC) in the double-camera system on the GaoFen2 optical remote sensing satellite (GF2). A big virtual camera can be built according to the rigorous imaging model of a single camera; then, each single image strip obtained by each TDI-CCD detector can be re-projected to the virtual detector of the big virtual camera coordinate system using forward-projection and backward-projection to obtain the corresponding single virtual image. After an on-orbit calibration and relative orientation, the complete final virtual image can be obtained by stitching the single virtual images together based on their coordinate information on the big virtual detector image plane. The paper subtly uses the concept of the big virtual camera to obtain a stitched image and the corresponding high accuracy rational function model (RFM) for concurrent post processing. Experiments verified that the proposed method can achieve seamless mosaicking while maintaining the geometric accuracy.
NASA Technical Reports Server (NTRS)
Voellmer, George M.; Allen, Christine A.; Amato, Michael J.; Babu, Sachidananda R.; Bartels, Arlin E.; Benford, Dominic J.; Derro, Rebecca J.; Dowell, C. Darren; Harper, D. Al; Jhabvala, Murzy D.;
2002-01-01
The High resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC 11) will use almost identical versions of an ion-implanted silicon bolometer array developed at the National Aeronautics and Space Administration's Goddard Space Flight Center (GSFC). The GSFC "Pop-Up" Detectors (PUD's) use a unique folding technique to enable a 12 x 32-element close-packed array of bolometers with a filling factor greater than 95 percent. A kinematic Kevlar(Registered Trademark) suspension system isolates the 200 mK bolometers from the helium bath temperature, and GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The JFET preamps operate at 120 K. Providing good thermal heat sinking for these, and keeping their conduction and radiation from reaching the nearby bolometers, is one of the principal design challenges encountered. Another interesting challenge is the preparation of the silicon bolometers. They are manufactured in 32-element, planar rows using Micro Electro Mechanical Systems (MEMS) semiconductor etching techniques, and then cut and folded onto a ceramic bar. Optical alignment using specialized jigs ensures their uniformity and correct placement. The rows are then stacked to create the 12 x 32-element array. Engineering results from the first light run of SHARC II at the CalTech Submillimeter Observatory (CSO) are presented.
NASA Technical Reports Server (NTRS)
Voellmer, George M.; Allen, Christine A.; Amato, Michael J.; Babu, Sachidananda R.; Bartels, Arlin E.; Benford, Dominic J.; Derro, Rebecca J.; Dowell, C. Darren; Harper, D. Al; Jhabvala, Murzy D.
2002-01-01
The High resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC II) will use almost identical versions of an ion-implanted silicon bolometer array developed at the National Aeronautics and Space Administration's Goddard Space Flight Center (GSFC). The GSFC 'Pop-up' Detectors (PUD's) use a unique folding technique to enable a 12 x 32-element close-packed array of bolometers with a filling factor greater than 95 percent. A kinematic Kevlar(trademark) suspension system isolates the 200 mK bolometers from the helium bath temperature, and GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The JFET preamps operate at 120 K. Providing good thermal heat sinking for these, and keeping their conduction and radiation from reaching the nearby bolometers, is one of the principal design challenges encountered. Another interesting challenge is the preparation of the silicon bolometers. They are manufactured in 32-element, planar rows using Micro Electro Mechanical Systems (MEMS) semiconductor etching techniques, and then cut and folded onto a ceramic bar. Optical alignment using specialized jigs ensures their uniformity and correct placement. The rows are then stacked to create the 12 x 32-element array. Engineering results from the first light run of SHARC II at the Caltech Submillimeter Observatory (CSO) are presented.
Dense Region of Impact Craters
2011-09-23
NASA Dawn spacecraft obtained this image of the giant asteroid Vesta with its framing camera on Aug. 14 2011. This image was taken through the camera clear filter. The image has a resolution of about 260 meters per pixel.
Camera Ready to Install on Mars Reconnaissance Orbiter
2005-01-07
A telescopic camera called the High Resolution Imaging Science Experiment, or HiRISE, right was installed onto the main structure of NASA Mars Reconnaissance Orbiter left on Dec. 11, 2004 at Lockheed Martin Space Systems, Denver.
Depth profile measurement with lenslet images of the plenoptic camera
NASA Astrophysics Data System (ADS)
Yang, Peng; Wang, Zhaomin; Zhang, Wei; Zhao, Hongying; Qu, Weijuan; Zhao, Haimeng; Asundi, Anand; Yan, Lei
2018-03-01
An approach for carrying out depth profile measurement of an object with the plenoptic camera is proposed. A single plenoptic image consists of multiple lenslet images. To begin with, these images are processed directly with a refocusing technique to obtain the depth map, which does not need to align and decode the plenoptic image. Then, a linear depth calibration is applied based on the optical structure of the plenoptic camera for depth profile reconstruction. One significant improvement of the proposed method concerns the resolution of the depth map. Unlike the traditional method, our resolution is not limited by the number of microlenses inside the camera, and the depth map can be globally optimized. We validated the method with experiments on depth map reconstruction, depth calibration, and depth profile measurement, with the results indicating that the proposed approach is both efficient and accurate.
Inexpensive Neutron Imaging Cameras Using CCDs for Astronomy
NASA Astrophysics Data System (ADS)
Hewat, A. W.
We have developed inexpensive neutron imaging cameras using CCDs originally designed for amateur astronomical observation. The low-light, high resolution requirements of such CCDs are similar to those for neutron imaging, except that noise as well as cost is reduced by using slower read-out electronics. For example, we use the same 2048x2048 pixel ;Kodak; KAI-4022 CCD as used in the high performance PCO-2000 CCD camera, but our electronics requires ∼5 sec for full-frame read-out, ten times slower than the PCO-2000. Since neutron exposures also require several seconds, this is not seen as a serious disadvantage for many applications. If higher frame rates are needed, the CCD unit on our camera can be easily swapped for a faster readout detector with similar chip size and resolution, such as the PCO-2000 or the sCMOS PCO.edge 4.2.
A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload
NASA Technical Reports Server (NTRS)
Golub, Leon
1989-01-01
Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.
Development of the geoCamera, a System for Mapping Ice from a Ship
NASA Astrophysics Data System (ADS)
Arsenault, R.; Clemente-Colon, P.
2012-12-01
The geoCamera produces maps of the ice surrounding an ice-capable ship by combining images from one or more digital cameras with the ship's position and attitude data. Maps are produced along the ship's path with the achievable width and resolution depending on camera mounting height as well as camera resolution and lens parameters. Our system has produced maps up to 2000m wide at 1m resolution. Once installed and calibrated, the system is designed to operate automatically producing maps in near real-time and making them available to on-board users via existing information systems. The resulting small-scale maps complement existing satellite based products as well as on-board observations. Development versions have temporarily been deployed in Antarctica on the RV Nathaniel B. Palmer in 2010 and in the Arctic on the USCGC Healy in 2011. A permanent system has been deployed during the summer of 2012 on the USCGC Healy. To make the system attractive to other ships of opportunity, design goals include using existing ship systems when practical, using low costs commercial-off-the-shelf components if additional hardware is necessary, automating the process to virtually eliminate adding to the workload of ships technicians and making the software components modular and flexible enough to allow more seamless integration with a ships particular IT system.
Electronic cameras for low-light microscopy.
Rasnik, Ivan; French, Todd; Jacobson, Ken; Berland, Keith
2013-01-01
This chapter introduces to electronic cameras, discusses the various parameters considered for evaluating their performance, and describes some of the key features of different camera formats. The chapter also presents the basic understanding of functioning of the electronic cameras and how these properties can be exploited to optimize image quality under low-light conditions. Although there are many types of cameras available for microscopy, the most reliable type is the charge-coupled device (CCD) camera, which remains preferred for high-performance systems. If time resolution and frame rate are of no concern, slow-scan CCDs certainly offer the best available performance, both in terms of the signal-to-noise ratio and their spatial resolution. Slow-scan cameras are thus the first choice for experiments using fixed specimens such as measurements using immune fluorescence and fluorescence in situ hybridization. However, if video rate imaging is required, one need not evaluate slow-scan CCD cameras. A very basic video CCD may suffice if samples are heavily labeled or are not perturbed by high intensity illumination. When video rate imaging is required for very dim specimens, the electron multiplying CCD camera is probably the most appropriate at this technological stage. Intensified CCDs provide a unique tool for applications in which high-speed gating is required. The variable integration time video cameras are very attractive options if one needs to acquire images at video rate acquisition, as well as with longer integration times for less bright samples. This flexibility can facilitate many diverse applications with highly varied light levels. Copyright © 2007 Elsevier Inc. All rights reserved.
Coincidence electron/ion imaging with a fast frame camera
NASA Astrophysics Data System (ADS)
Li, Wen; Lee, Suk Kyoung; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander; Fan, Lin
2015-05-01
A new time- and position- sensitive particle detection system based on a fast frame CMOS camera is developed for coincidence electron/ion imaging. The system is composed of three major components: a conventional microchannel plate (MCP)/phosphor screen electron/ion imager, a fast frame CMOS camera and a high-speed digitizer. The system collects the positional information of ions/electrons from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of MCPs processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of electron/ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide. We further show that a time resolution of 30 ps can be achieved when measuring electron TOF spectrum and this enables the new system to achieve a good energy resolution along the TOF axis.
The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray Detector (SGD)
NASA Astrophysics Data System (ADS)
Watanabe, Shin; Tajima, Hiroyasu; Fukazawa, Yasushi; Ichinohe, Yuto; Takeda, Shin`ichiro; Enoto, Teruaki; Fukuyama, Taro; Furui, Shunya; Genba, Kei; Hagino, Kouichi; Harayama, Atsushi; Kuroda, Yoshikatsu; Matsuura, Daisuke; Nakamura, Ryo; Nakazawa, Kazuhiro; Noda, Hirofumi; Odaka, Hirokazu; Ohta, Masayuki; Onishi, Mitsunobu; Saito, Shinya; Sato, Goro; Sato, Tamotsu; Takahashi, Tadayuki; Tanaka, Takaaki; Togo, Atsushi; Tomizuka, Shinji
2014-11-01
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60-600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and cadmium telluride (CdTe) sensors. The design of the SGD Compton camera has been finalized and the final prototype, which has the same configuration as the flight model, has been fabricated for performance evaluation. The Compton camera has overall dimensions of 12 cm×12 cm×12 cm, consisting of 32 layers of Si pixel sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel sensors. The detection efficiency of the Compton camera reaches about 15% and 3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si and CdTe sensors is 3.2 mm, and the signals from all 13,312 pixels are processed by 208 ASICs developed for the SGD. Good energy resolution is afforded by semiconductor sensors and low noise ASICs, and the obtained energy resolutions with the prototype Si and CdTe pixel sensors are 1.0-2.0 keV (FWHM) at 60 keV and 1.6-2.5 keV (FWHM) at 122 keV, respectively. This results in good background rejection capability due to better constraints on Compton kinematics. Compton camera energy resolutions achieved with the final prototype are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, which satisfy the instrument requirements for the SGD Compton camera (better than 2%). Moreover, a low intrinsic background has been confirmed by the background measurement with the final prototype.
Short-term Recovery Following Resistance Exercise Leading or not to Failure.
González-Badillo, J J; Rodríguez-Rosell, D; Sánchez-Medina, L; Ribas, J; López-López, C; Mora-Custodio, R; Yañez-García, J M; Pareja-Blanco, F
2016-04-01
This study analyzed the time course of recovery following 2 resistance exercise protocols differing in level of effort: maximum (to failure) vs. half-maximum number of repetitions per set. 9 males performed 3 sets of 4 vs. 8 repetitions with their 80% 1RM load, 3×4(8) vs. 3×8(8), in the bench press and squat. Several time-points from 24 h pre- to 48 h post-exercise were established to assess the mechanical (countermovement jump height, CMJ; velocity against the 1 m·s(-1) load, V1-load), biochemical (testosterone, cortisol, GH, prolactin, IGF-1, CK) and heart rate variability (HRV) and complexity (HRC) response to exercise. 3×8(8) resulted in greater neuromuscular fatigue (higher reductions in repetition velocity and velocity against V1-load) than 3×4(8). CMJ remained reduced up to 48 h post-exercise following 3×8(8), whereas it was recovered after 6 h for 3×4(8). Significantly greater prolactin and IGF-1 levels were found for 3×8(8) vs. 3×4(8). Significant reductions in HRV and HRC were observed for 3×8(8) vs. 3×4(8) in the immediate recovery. Performing a half-maximum number of repetitions per set resulted in: 1) a stimulus of faster mean repetition velocities; 2) lower impairment of neuromuscular performance and faster recovery; 3) reduced hormonal response and muscle damage; and 4) lower reduction in HRV and HRC following exercise. © Georg Thieme Verlag KG Stuttgart · New York.
McLoone, J K; Watts, K J; Menzies, S W; Barlow-Stewart, K; Mann, G J; Kasparian, N A
2013-09-01
Providing ongoing clinical care that adequately addresses patients' medical, psychosocial and information needs is challenging, particularly for patient groups at increased risk of developing life-threatening disease such as malignant melanoma. This study examined a model of clinical care developed by the High Risk Clinic (HRC) of the Sydney Melanoma Diagnostic Centre in relation to patient satisfaction. Semi-structured telephone interviews were conducted and analyzed using the framework of Miles and Huberman, and themes were organized using the qualitative software package, QSR NVivo8. Twenty HRC patients participated in the study (nine men, 11 women; mean age 57.6 years, age range 34-74 years; response rate 91%). Satisfaction with clinical care at the HRC was high. Factors contributing to patient satisfaction included: rapid and regular access to physicians who were perceived by participants as experts, the development of confidence and trust in one's treating doctor, and a sense of being cared about and understood by one's healthcare team. Although one-third of the participants reported some inconveniences in attending the clinic, these were viewed as minor difficulties and not significant barriers to care. Formal psychological support was not sought or expected by participants, although many expressed long-standing melanoma-related fears and concerns. Accessible, expert medical attention, delivered in a patient-centered manner was integral to melanoma survivors' satisfaction with clinical management. Appropriate referrals to psychological support may further increase satisfaction with clinical care. Copyright © 2013 John Wiley & Sons, Ltd.
Pole Photogrammetry with AN Action Camera for Fast and Accurate Surface Mapping
NASA Astrophysics Data System (ADS)
Gonçalves, J. A.; Moutinho, O. F.; Rodrigues, A. C.
2016-06-01
High resolution and high accuracy terrain mapping can provide height change detection for studies of erosion, subsidence or land slip. A UAV flying at a low altitude above the ground, with a compact camera, acquires images with resolution appropriate for these change detections. However, there may be situations where different approaches may be needed, either because higher resolution is required or the operation of a drone is not possible. Pole photogrammetry, where a camera is mounted on a pole, pointing to the ground, is an alternative. This paper describes a very simple system of this kind, created for topographic change detection, based on an action camera. These cameras have high quality and very flexible image capture. Although radial distortion is normally high, it can be treated in an auto-calibration process. The system is composed by a light aluminium pole, 4 meters long, with a 12 megapixel GoPro camera. Average ground sampling distance at the image centre is 2.3 mm. The user moves along a path, taking successive photos, with a time lapse of 0.5 or 1 second, and adjusting the speed in order to have an appropriate overlap, with enough redundancy for 3D coordinate extraction. Marked ground control points are surveyed with GNSS for precise georeferencing of the DSM and orthoimage that are created by structure from motion processing software. An average vertical accuracy of 1 cm could be achieved, which is enough for many applications, for example for soil erosion. The GNSS survey in RTK mode with permanent stations is now very fast (5 seconds per point), which results, together with the image collection, in a very fast field work. If an improved accuracy is needed, since image resolution is 1/4 cm, it can be achieved using a total station for the control point survey, although the field work time increases.
Super-resolved all-refocused image with a plenoptic camera
NASA Astrophysics Data System (ADS)
Wang, Xiang; Li, Lin; Hou, Guangqi
2015-12-01
This paper proposes an approach to produce the super-resolution all-refocused images with the plenoptic camera. The plenoptic camera can be produced by putting a micro-lens array between the lens and the sensor in a conventional camera. This kind of camera captures both the angular and spatial information of the scene in one single shot. A sequence of digital refocused images, which are refocused at different depth, can be produced after processing the 4D light field captured by the plenoptic camera. The number of the pixels in the refocused image is the same as that of the micro-lens in the micro-lens array. Limited number of the micro-lens will result in poor low resolution refocused images. Therefore, not enough details will exist in these images. Such lost details, which are often high frequency information, are important for the in-focus part in the refocused image. We decide to super-resolve these in-focus parts. The result of image segmentation method based on random walks, which works on the depth map produced from the 4D light field data, is used to separate the foreground and background in the refocused image. And focusing evaluation function is employed to determine which refocused image owns the clearest foreground part and which one owns the clearest background part. Subsequently, we employ single image super-resolution method based on sparse signal representation to process the focusing parts in these selected refocused images. Eventually, we can obtain the super-resolved all-focus image through merging the focusing background part and the focusing foreground part in the way of digital signal processing. And more spatial details will be kept in these output images. Our method will enhance the resolution of the refocused image, and just the refocused images owning the clearest foreground and background need to be super-resolved.
NASA Astrophysics Data System (ADS)
Dekemper, Emmanuel; Vanhamel, Jurgen; Van Opstal, Bert; Fussen, Didier
2016-12-01
The abundance of NO2 in the boundary layer relates to air quality and pollution source monitoring. Observing the spatiotemporal distribution of NO2 above well-delimited (flue gas stacks, volcanoes, ships) or more extended sources (cities) allows for applications such as monitoring emission fluxes or studying the plume dynamic chemistry and its transport. So far, most attempts to map the NO2 field from the ground have been made with visible-light scanning grating spectrometers. Benefiting from a high retrieval accuracy, they only achieve a relatively low spatiotemporal resolution that hampers the detection of dynamic features. We present a new type of passive remote sensing instrument aiming at the measurement of the 2-D distributions of NO2 slant column densities (SCDs) with a high spatiotemporal resolution. The measurement principle has strong similarities with the popular filter-based SO2 camera as it relies on spectral images taken at wavelengths where the molecule absorption cross section is different. Contrary to the SO2 camera, the spectral selection is performed by an acousto-optical tunable filter (AOTF) capable of resolving the target molecule's spectral features. The NO2 camera capabilities are demonstrated by imaging the NO2 abundance in the plume of a coal-fired power plant. During this experiment, the 2-D distribution of the NO2 SCD was retrieved with a temporal resolution of 3 min and a spatial sampling of 50 cm (over a 250 × 250 m2 area). The detection limit was close to 5 × 1016 molecules cm-2, with a maximum detected SCD of 4 × 1017 molecules cm-2. Illustrating the added value of the NO2 camera measurements, the data reveal the dynamics of the NO to NO2 conversion in the early plume with an unprecedent resolution: from its release in the air, and for 100 m upwards, the observed NO2 plume concentration increased at a rate of 0.75-1.25 g s-1. In joint campaigns with SO2 cameras, the NO2 camera could also help in removing the bias introduced by the NO2 interference with the SO2 spectrum.
NASA Astrophysics Data System (ADS)
Blackford, Ethan B.; Estepp, Justin R.
2015-03-01
Non-contact, imaging photoplethysmography uses cameras to facilitate measurements including pulse rate, pulse rate variability, respiration rate, and blood perfusion by measuring characteristic changes in light absorption at the skin's surface resulting from changes in blood volume in the superficial microvasculature. Several factors may affect the accuracy of the physiological measurement including imager frame rate, resolution, compression, lighting conditions, image background, participant skin tone, and participant motion. Before this method can gain wider use outside basic research settings, its constraints and capabilities must be well understood. Recently, we presented a novel approach utilizing a synchronized, nine-camera, semicircular array backed by measurement of an electrocardiogram and fingertip reflectance photoplethysmogram. Twenty-five individuals participated in six, five-minute, controlled head motion artifact trials in front of a black and dynamic color backdrop. Increasing the input channel space for blind source separation using the camera array was effective in mitigating error from head motion artifact. Herein we present the effects of lower frame rates at 60 and 30 (reduced from 120) frames per second and reduced image resolution at 329x246 pixels (one-quarter of the original 658x492 pixel resolution) using bilinear and zero-order downsampling. This is the first time these factors have been examined for a multiple imager array and align well with previous findings utilizing a single imager. Examining windowed pulse rates, there is little observable difference in mean absolute error or error distributions resulting from reduced frame rates or image resolution, thus lowering requirements for systems measuring pulse rate over sufficient length time windows.
PN-CCD camera for XMM: performance of high time resolution/bright source operating modes
NASA Astrophysics Data System (ADS)
Kendziorra, Eckhard; Bihler, Edgar; Grubmiller, Willy; Kretschmar, Baerbel; Kuster, Markus; Pflueger, Bernhard; Staubert, Ruediger; Braeuninger, Heinrich W.; Briel, Ulrich G.; Meidinger, Norbert; Pfeffermann, Elmar; Reppin, Claus; Stoetter, Diana; Strueder, Lothar; Holl, Peter; Kemmer, Josef; Soltau, Heike; von Zanthier, Christoph
1997-10-01
The pn-CCD camera is developed as one of the focal plane instruments for the European photon imaging camera (EPIC) on board the x-ray multi mirror (XMM) mission to be launched in 1999. The detector consists of four quadrants of three pn-CCDs each, which are integrated on one silicon wafer. Each CCD has 200 by 64 pixels (150 micrometer by 150 micrometers) with 280 micrometers depletion depth. One CCD of a quadrant is read out at a time, while the four quadrants can be processed independently of each other. In standard imaging mode the CCDs are read out sequentially every 70 ms. Observations of point sources brighter than 1 mCrab will be effected by photon pile- up. However, special operating modes can be used to observe bright sources up to 150 mCrab in timing mode with 30 microseconds time resolution and very bright sources up to several crab in burst mode with 7 microseconds time resolution. We have tested one quadrant of the EPIC pn-CCD camera at line energies from 0.52 keV to 17.4 keV at the long beam test facility Panter in the focus of the qualification mirror module for XMM. In order to test the time resolution of the system, a mechanical chopper was used to periodically modulate the beam intensity. Pulse periods down to 0.7 ms were generated. This paper describes the performance of the pn-CCD detector in timing and burst readout modes with special emphasis on energy and time resolution.
NASA Technical Reports Server (NTRS)
Grubbs, Rodney
2016-01-01
The first live High Definition Television (HDTV) from a spacecraft was in November, 2006, nearly ten years before the 2016 SpaceOps Conference. Much has changed since then. Now, live HDTV from the International Space Station (ISS) is routine. HDTV cameras stream live video views of the Earth from the exterior of the ISS every day on UStream, and HDTV has even flown around the Moon on a Japanese Space Agency spacecraft. A great deal has been learned about the operations applicability of HDTV and high resolution imagery since that first live broadcast. This paper will discuss the current state of real-time and file based HDTV and higher resolution video for space operations. A potential roadmap will be provided for further development and innovations of high-resolution digital motion imagery, including gaps in technology enablers, especially for deep space and unmanned missions. Specific topics to be covered in the paper will include: An update on radiation tolerance and performance of various camera types and sensors and ramifications on the future applicability of these types of cameras for space operations; Practical experience with downlinking very large imagery files with breaks in link coverage; Ramifications of larger camera resolutions like Ultra-High Definition, 6,000 [pixels] and 8,000 [pixels] in space applications; Enabling technologies such as the High Efficiency Video Codec, Bundle Streaming Delay Tolerant Networking, Optical Communications and Bayer Pattern Sensors and other similar innovations; Likely future operations scenarios for deep space missions with extreme latency and intermittent communications links.
Video Capture of Perforator Flap Harvesting Procedure with a Full High-definition Wearable Camera
2016-01-01
Summary: Recent advances in wearable recording technology have enabled high-quality video recording of several surgical procedures from the surgeon’s perspective. However, the available wearable cameras are not optimal for recording the harvesting of perforator flaps because they are too heavy and cannot be attached to the surgical loupe. The Ecous is a small high-resolution camera that was specially developed for recording loupe magnification surgery. This study investigated the use of the Ecous for recording perforator flap harvesting procedures. The Ecous SC MiCron is a high-resolution camera that can be mounted directly on the surgical loupe. The camera is light (30 g) and measures only 28 × 32 × 60 mm. We recorded 23 perforator flap harvesting procedures with the Ecous connected to a laptop through a USB cable. The elevated flaps included 9 deep inferior epigastric artery perforator flaps, 7 thoracodorsal artery perforator flaps, 4 anterolateral thigh flaps, and 3 superficial inferior epigastric artery flaps. All procedures were recorded with no equipment failure. The Ecous recorded the technical details of the perforator dissection at a high-resolution level. The surgeon did not feel any extra stress or interference when wearing the Ecous. The Ecous is an ideal camera for recording perforator flap harvesting procedures. It fits onto the surgical loupe perfectly without creating additional stress on the surgeon. High-quality video from the surgeon’s perspective makes accurate documentation of the procedures possible, thereby enhancing surgical education and allowing critical self-reflection. PMID:27482504
Accuracy Assessment of GO Pro Hero 3 (black) Camera in Underwater Environment
NASA Astrophysics Data System (ADS)
Helmholz, , P.; Long, J.; Munsie, T.; Belton, D.
2016-06-01
Modern digital cameras are increasing in quality whilst decreasing in size. In the last decade, a number of waterproof consumer digital cameras (action cameras) have become available, which often cost less than 500. A possible application of such action cameras is in the field of Underwater Photogrammetry. Especially with respect to the fact that with the change of the medium to below water can in turn counteract the distortions present. The goal of this paper is to investigate the suitability of such action cameras for underwater photogrammetric applications focusing on the stability of the camera and the accuracy of the derived coordinates for possible photogrammetric applications. For this paper a series of image sequences was capture in a water tank. A calibration frame was placed in the water tank allowing the calibration of the camera and the validation of the measurements using check points. The accuracy assessment covered three test sets operating three GoPro sports cameras of the same model (Hero 3 black). The test set included the handling of the camera in a controlled manner where the camera was only dunked into the water tank using 7MP and 12MP resolution and a rough handling where the camera was shaken as well as being removed from the waterproof case using 12MP resolution. The tests showed that the camera stability was given with a maximum standard deviation of the camera constant σc of 0.0031mm for 7MB (for an average c of 2.720mm) and 0.0072 mm for 12MB (for an average c of 3.642mm). The residual test of the check points gave for the 7MB test series the largest rms value with only 0.450mm and the largest maximal residual of only 2.5 mm. For the 12MB test series the maximum rms value is 0. 653mm.
Design principles and applications of a cooled CCD camera for electron microscopy.
Faruqi, A R
1998-01-01
Cooled CCD cameras offer a number of advantages in recording electron microscope images with CCDs rather than film which include: immediate availability of the image in a digital format suitable for further computer processing, high dynamic range, excellent linearity and a high detective quantum efficiency for recording electrons. In one important respect however, film has superior properties: the spatial resolution of CCD detectors tested so far (in terms of point spread function or modulation transfer function) are inferior to film and a great deal of our effort has been spent in designing detectors with improved spatial resolution. Various instrumental contributions to spatial resolution have been analysed and in this paper we discuss the contribution of the phosphor-fibre optics system in this measurement. We have evaluated the performance of a number of detector components and parameters, e.g. different phosphors (and a scintillator), optical coupling with lens or fibre optics with various demagnification factors, to improve the detector performance. The camera described in this paper, which is based on this analysis, uses a tapered fibre optics coupling between the phosphor and the CCD and is installed on a Philips CM12 electron microscope equipped to perform cryo-microscopy. The main use of the camera so far has been in recording electron diffraction patterns from two dimensional crystals of bacteriorhodopsin--from wild type and from different trapped states during the photocycle. As one example of the type of data obtained with the CCD camera a two dimensional Fourier projection map from the trapped O-state is also included. With faster computers, it will soon be possible to undertake this type of work on an on-line basis. Also, with improvements in detector size and resolution, CCD detectors, already ideal for diffraction, will be able to compete with film in the recording of high resolution images.
Rapid orthophoto development system.
DOT National Transportation Integrated Search
2013-06-01
The DMC system procured in the project represented state-of-the-art, large-format digital aerial camera systems at the start of : project. DMC is based on the frame camera model, and to achieve large ground coverage with high spatial resolution, the ...
NASA Astrophysics Data System (ADS)
Hazen, T. C.; Faybishenko, B.; Beller, H. R.; Brodie, E. L.; Sonnenthal, E. L.; Steefel, C.; Larsen, J.; Conrad, M. E.; Bill, M.; Christensen, J. N.; Brown, S. T.; Joyner, D.; Borglin, S. E.; Geller, J. T.; Chakraborty, R.; Nico, P. S.; Long, P. E.; Newcomer, D. R.; Arntzen, E.
2011-12-01
The primary contaminant of concern in groundwater at the DOE Hanford 100 Area (Washington State) is hexavalent chromium [Cr(VI)] in Hanford coarse-grained sediments. Three lactate injections were conducted in March, August, and October 2010 at the Hanford 100-H field site to assess the efficacy of in situ Cr(VI) bioreductive immobilization. Each time, 55 gal of lactate solution was injected into the Hanford aquifer. To characterize the biogeochemical regimes before and after electron donor injection, we implemented a comprehensive plan of groundwater sampling for microbial, geochemical, and isotopic analyses. These tests were performed to provide evidence of transformation of toxic and soluble Cr(VI) into less toxic and poorly soluble Cr(III) by bioimmobilization, and to quantify critical and interrelated microbial metabolic and geochemical mechanisms affecting chromium in situ reductive immobilization and the long-term sustainability of chromium bioremediation. The results of lactate injections were compared with data from two groundwater biostimulation tests that were conducted in 2004 and 2008 by injecting Hydrogen Release Compound (HRC°), a slow-release glycerol polylactate, into the Hanford aquifer. In all HRC and lactate injection tests, 13C-labeled lactate was added to the injected solutions to track post-injection carbon pathways. Monitoring showed that despite a very low initial total microbial density (from <104 to 105 cells/mL), both HRC and lactate injections stimulated anaerobic microbial activity, which led to an increase in biomass to >107 cells/mL (including sulfate- and nitrate-reducing bacteria), resulting in a significant decrease in soluble Cr(VI) concentrations to below the MCL. In all tests, lactate was consumed nearly completely within the first week, much faster than HRC. Modeling of biogeochemical and isotope fractionation processes with the reaction-transport code TOUGHREACT captured the biodegradation of lactate, fermentative production of acetate and propionate, the evolution of 13C in bicarbonate, and the rate of sulfate reduction. In contrast to the slow-release HRC injections, no long-term effects of biostimulation and Cr bioreduction were observed in groundwater after the lactate injections. The presentation will address these patterns of the geochemical, δ13C of DIC, and biomass changes in groundwater before and after the polylactate and lactate injections.
The nature of X-ray selected star candidates
NASA Astrophysics Data System (ADS)
Mickaelian, A. M.; Paronyan, G. M.; Abrahamyan, H. V.; Gigoyan, K. S.; Gyulzadyan, M. V.; Kostandyan, G. R.
2016-12-01
The joint HRC/BHRC catalogue of optical identifications of ROSAT BSC and FSC X-ray sources is based on merging the Hamburg-ROSAT Catalogue (HRC) and Byurakan-Hamburg-ROSAT Catalogue (BHRC). Both have been made by optical identifications of X-ray sources based on low-dispersion spectra of the Hamburg QuasarSurvey (HQS) using the ROSAT Catalogues. HRC/BHRC contains a sample of 8132 (5341+2791) optically identified X-ray sources with count rate (CR) of photons ≥ 0.04 ct/s in the area of the low-dispersion Hamburg Quasar Survey (HQS), |b| ≥ 20° and δ ≥ 0°. Based on low-dispersion spectral classification, there are 4253 AGN, 492 galaxies, 1800 stars and 1587 unknown objects in the sample. 1800 star candidates include 1429 objects listed in SDSS DR12 photometric catalogue and 433 given in SDSS spectroscopic catalogue. Using these spectra, we have carried out classification of these star candidates to reveal new interesting objects, as well as to define the true content of our sample. 34 cataclysmic variables (including 7 new ones), 19 white dwarfs, 19 late-type stars (K-M and C types), 16 early type stars (O-B), 40 hot coronal stars (A-F types), 2 composite spectrum objects, and 17 bright stars have been revealed, as well as 286 objects which turned out to be extragalactic ones; 75 emission-line galaxies (HII/SB and AGN, including QSOs, Seyferts, and LINERs) and 211 absorption line galaxies were revealed (wrong classifications in HRC/BHRC due to their faint images and low-quality spectra). We have retrieved multiwavelength data from recent catalogues and carried out statistical investigations of the multiwavelength properties for the whole sample of stars. All stars have been found in GSC 2.3.2, as well as most of them are in GALEX, USNO-B1.0, 2MASS and WISE catalogues. Relations between the radiation fluxes in different bands from X-ray to radio for different types of sources are studied and analysis of their characteristics is made. X-ray selected stars are an important complement to the stellar populations of our Galaxy in solar neighbourhood and beyond. Keywords: X-ray sources, cross-correlations, white dwarfs, cataclysmic variables, carbon stars
NASA Technical Reports Server (NTRS)
1996-01-01
PixelVision, Inc. developed the Night Video NV652 Back-illuminated CCD Camera, based on the expertise of a former Jet Propulsion Laboratory employee and a former employee of Scientific Imaging Technologies, Inc. The camera operates without an image intensifier, using back-illuminated and thinned CCD technology to achieve extremely low light level imaging performance. The advantages of PixelVision's system over conventional cameras include greater resolution and better target identification under low light conditions, lower cost and a longer lifetime. It is used commercially for research and aviation.
Development of a high spatial resolution neutron imaging system and performance evaluation
NASA Astrophysics Data System (ADS)
Cao, Lei
The combination of a scintillation screen and a charged coupled device (CCD) camera is a digitized neutron imaging technology that has been widely employed for research and industry application. The maximum of spatial resolution of scintillation screens is in the range of 100 mum and creates a bottleneck for the further improvement of the overall system resolution. In this investigation, a neutron sensitive micro-channel plate (MCP) detector with pore pitch of 11.4 mum is combined with a cooled CCD camera with a pixel size of 6.8 mum to provide a high spatial resolution neutron imaging system. The optical path includes a high reflection front surface mirror for keeping the camera out of neutron beam and a macro lens for achieving the maximum magnification that could be achieved. All components are assembled into an aluminum light tight box with heavy radiation shielding to protect the camera as well as to provide a dark working condition. Particularly, a remote controlled stepper motor is also integrated into the system to provide on-line focusing ability. The best focus is guaranteed through use of an algorithm instead of perceptual observation. An evaluation routine not previously utilized in the field of neutron radiography is developed in this study. Routines like this were never previously required due to the lower resolution of other systems. Use of the augulation technique to obtain presampled MTF addresses the problem of aliasing associated with digital sampling. The determined MTF agrees well with the visual inspection of imaging a testing target. Other detector/camera combinations may be integrated into the system and their performances are also compared. The best resolution achieved by the system at the TRIGA Mark II reactor at the University of Texas at Austin is 16.2 lp/mm, which is equivalent to a minimum resolvable spacing of 30 mum. The noise performance of the device is evaluated in terms of the noise power spectrum (NPS) and the detective quantum efficiency (DQE) is calculated with above determined MTF and NPS.
An Overview of the CBERS-2 Satellite and Comparison of the CBERS-2 CCD Data with the L5 TM Data
NASA Technical Reports Server (NTRS)
Chandler, Gyanesh
2007-01-01
CBERS satellite carries on-board a multi sensor payload with different spatial resolutions and collection frequencies. HRCCD (High Resolution CCD Camera), IRMSS (Infrared Multispectral Scanner), and WFI (Wide-Field Imager). The CCD and the WFI camera operate in the VNIR regions, while the IRMSS operates in SWIR and thermal region. In addition to the imaging payload, the satellite carries a Data Collection System (DCS) and Space Environment Monitor (SEM).
NASA Technical Reports Server (NTRS)
Albrecht, R.; Barbieri, C.; Adorf, H.-M.; Corrain, G.; Gemmo, A.; Greenfield, P.; Hainaut, O.; Hook, R. N.; Tholen, D. J.; Blades, J. C.
1994-01-01
Images of the Pluto-Charon system were obtained with the Faint Object Camera (FOC) of the Hubble Space Telescope (HST) after the refurbishment of the telescope. The images are of superb quality, allowing the determination of radii, fluxes, and albedos. Attempts were made to improve the resolution of the already diffraction limited images by image restoration. These yielded indications of surface albedo distributions qualitatively consistent with models derived from observations of Pluto-Charon mutual eclipses.
Low-cost mobile phone microscopy with a reversed mobile phone camera lens.
Switz, Neil A; D'Ambrosio, Michael V; Fletcher, Daniel A
2014-01-01
The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.
Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens
Fletcher, Daniel A.
2014-01-01
The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples. PMID:24854188
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacPhee, A. G., E-mail: macphee2@llnl.gov; Hatch, B. W.; Bell, P. M.
2016-11-15
We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamicmore » range for the relevant part of the streak record.« less
MacPhee, A G; Dymoke-Bradshaw, A K L; Hares, J D; Hassett, J; Hatch, B W; Meadowcroft, A L; Bell, P M; Bradley, D K; Datte, P S; Landen, O L; Palmer, N E; Piston, K W; Rekow, V V; Hilsabeck, T J; Kilkenny, J D
2016-11-01
We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.
A neutron camera system for MAST.
Cecconello, M; Turnyanskiy, M; Conroy, S; Ericsson, G; Ronchi, E; Sangaroon, S; Akers, R; Fitzgerald, I; Cullen, A; Weiszflog, M
2010-10-01
A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination. The preliminary results obtained clearly show the capability of this diagnostic to measure neutron emissivity profiles with sufficient time resolution to study the effect of fast ion loss and redistribution due to magnetohydrodynamic activity. A minimum time resolution of 2 ms has been achieved with a modest 1.5 MW of neutral beam injection heating with a measured neutron count rate of a few 100 kHz.
Colors of active regions on comet 67P
NASA Astrophysics Data System (ADS)
Oklay, N.; Vincent, J.-B.; Sierks, H.; Besse, S.; Fornasier, S.; Barucci, M. A.; Lara, L.; Scholten, F.; Preusker, F.; Lazzarin, M.; Pajola, M.; La Forgia, F.
2015-10-01
The OSIRIS (Optical, Spectroscopic, and Infrared Remote Imaging System) scientific imager (Keller et al. 2007) is successfully delivering images of comet 67P/Churyumov-Gerasimenko from its both wide angle camera (WAC) and narrow angle camera (NAC) since ESA's spacecraft Rosetta's arrival to the comet. Both cameras are equipped with filters covering the wavelength range of about 200 nm to 1000 nm. The comet nucleus is mapped with different combination of the filters in resolutions up to 15 cm/px. Besides the determination of the surface morphology in great details (Thomas et al. 2015), such high resolution images provided us a mean to unambiguously link some activity in the coma to a series of pits on the nucleus surface (Vincent et al. 2015).
New concept high-speed and high-resolution color scanner
NASA Astrophysics Data System (ADS)
Nakashima, Keisuke; Shinoda, Shin'ichi; Konishi, Yoshiharu; Sugiyama, Kenji; Hori, Tetsuya
2003-05-01
We have developed a new concept high-speed and high-resolution color scanner (Blinkscan) using digital camera technology. With our most advanced sub-pixel image processing technology, approximately 12 million pixel image data can be captured. High resolution imaging capability allows various uses such as OCR, color document read, and document camera. The scan time is only about 3 seconds for a letter size sheet. Blinkscan scans documents placed "face up" on its scan stage and without any special illumination lights. Using Blinkscan, a high-resolution color document can be easily inputted into a PC at high speed, a paperless system can be built easily. It is small, and since the occupancy area is also small, setting it on an individual desk is possible. Blinkscan offers the usability of a digital camera and accuracy of a flatbed scanner with high-speed processing. Now, about several hundred of Blinkscan are mainly shipping for the receptionist operation in a bank and a security. We will show the high-speed and high-resolution architecture of Blinkscan. Comparing operation-time with conventional image capture device, the advantage of Blinkscan will make clear. And image evaluation for variety of environment, such as geometric distortions or non-uniformity of brightness, will be made.
HST Solar Arrays photographed by Electronic Still Camera
NASA Technical Reports Server (NTRS)
1993-01-01
This view, backdropped against the blackness of space shows one of two original Solar Arrays (SA) on the Hubble Space Telescope (HST). The scene was photographed with an Electronic Still Camera (ESC), and downlinked to ground controllers soon afterward. Electronic still photography is a technology which provides the means for a handheld camera to electronically capture and digitize an image with resolution approaching film quality.
Design Against Fatigue Failure.
at room temperature and 375 Hz . 7050-T73651 aluminum and D6ac steel *HRC 50) were tested in room air and dry and wet argon, whereas 2014-T6 aluminum and annealed D6ac steel were tested in room air only.
Electronic Still Camera Project on STS-48
NASA Technical Reports Server (NTRS)
1991-01-01
On behalf of NASA, the Office of Commercial Programs (OCP) has signed a Technical Exchange Agreement (TEA) with Autometric, Inc. (Autometric) of Alexandria, Virginia. The purpose of this agreement is to evaluate and analyze a high-resolution Electronic Still Camera (ESC) for potential commercial applications. During the mission, Autometric will provide unique photo analysis and hard-copy production. Once the mission is complete, Autometric will furnish NASA with an analysis of the ESC s capabilities. Electronic still photography is a developing technology providing the means by which a hand held camera electronically captures and produces a digital image with resolution approaching film quality. The digital image, stored on removable hard disks or small optical disks, can be converted to a format suitable for downlink transmission, or it can be enhanced using image processing software. The on-orbit ability to enhance or annotate high-resolution images and then downlink these images in real-time will greatly improve Space Shuttle and Space Station capabilities in Earth observations and on-board photo documentation.
Li, Jin; Liu, Zilong
2017-07-24
Remote sensing cameras in the visible/near infrared range are essential tools in Earth-observation, deep-space exploration, and celestial navigation. Their imaging performance, i.e. image quality here, directly determines the target-observation performance of a spacecraft, and even the successful completion of a space mission. Unfortunately, the camera itself, such as a optical system, a image sensor, and a electronic system, limits the on-orbit imaging performance. Here, we demonstrate an on-orbit high-resolution imaging method based on the invariable modulation transfer function (IMTF) of cameras. The IMTF, which is stable and invariable to the changing of ground targets, atmosphere, and environment on orbit or on the ground, depending on the camera itself, is extracted using a pixel optical focal-plane (PFP). The PFP produces multiple spatial frequency targets, which are used to calculate the IMTF at different frequencies. The resulting IMTF in combination with a constrained least-squares filter compensates for the IMTF, which represents the removal of the imaging effects limited by the camera itself. This method is experimentally confirmed. Experiments on an on-orbit panchromatic camera indicate that the proposed method increases 6.5 times of the average gradient, 3.3 times of the edge intensity, and 1.56 times of the MTF value compared to the case when IMTF is not used. This opens a door to push the limitation of a camera itself, enabling high-resolution on-orbit optical imaging.
NASA Technical Reports Server (NTRS)
1992-01-01
The IMAX camera system is used to record on-orbit activities of interest to the public. Because of the extremely high resolution of the IMAX camera, projector, and audio systems, the audience is afforded a motion picture experience unlike any other. IMAX and OMNIMAX motion picture systems were designed to create motion picture images of superior quality and audience impact. The IMAX camera is a 65 mm, single lens, reflex viewing design with a 15 perforation per frame horizontal pull across. The frame size is 2.06 x 2.77 inches. Film travels through the camera at a rate of 336 feet per minute when the camera is running at the standard 24 frames/sec.
Electronic Still Camera view of Aft end of Wide Field/Planetary Camera in HST
1993-12-06
S61-E-015 (6 Dec 1993) --- A close-up view of the aft part of the new Wide Field/Planetary Camera (WFPC-II) installed on the Hubble Space Telescope (HST). WFPC-II was photographed with the Electronic Still Camera (ESC) from inside Endeavour's cabin as astronauts F. Story Musgrave and Jeffrey A. Hoffman moved it from its stowage position onto the giant telescope. Electronic still photography is a relatively new technology which provides the means for a handheld camera to electronically capture and digitize an image with resolution approaching film quality. The electronic still camera has flown as an experiment on several other shuttle missions.
Object recognition through turbulence with a modified plenoptic camera
NASA Astrophysics Data System (ADS)
Wu, Chensheng; Ko, Jonathan; Davis, Christopher
2015-03-01
Atmospheric turbulence adds accumulated distortion to images obtained by cameras and surveillance systems. When the turbulence grows stronger or when the object is further away from the observer, increasing the recording device resolution helps little to improve the quality of the image. Many sophisticated methods to correct the distorted images have been invented, such as using a known feature on or near the target object to perform a deconvolution process, or use of adaptive optics. However, most of the methods depend heavily on the object's location, and optical ray propagation through the turbulence is not directly considered. Alternatively, selecting a lucky image over many frames provides a feasible solution, but at the cost of time. In our work, we propose an innovative approach to improving image quality through turbulence by making use of a modified plenoptic camera. This type of camera adds a micro-lens array to a traditional high-resolution camera to form a semi-camera array that records duplicate copies of the object as well as "superimposed" turbulence at slightly different angles. By performing several steps of image reconstruction, turbulence effects will be suppressed to reveal more details of the object independently (without finding references near the object). Meanwhile, the redundant information obtained by the plenoptic camera raises the possibility of performing lucky image algorithmic analysis with fewer frames, which is more efficient. In our work, the details of our modified plenoptic cameras and image processing algorithms will be introduced. The proposed method can be applied to coherently illuminated object as well as incoherently illuminated objects. Our result shows that the turbulence effect can be effectively suppressed by the plenoptic camera in the hardware layer and a reconstructed "lucky image" can help the viewer identify the object even when a "lucky image" by ordinary cameras is not achievable.
Improved scintimammography using a high-resolution camera mounted on an upright mammography gantry
NASA Astrophysics Data System (ADS)
Itti, Emmanuel; Patt, Bradley E.; Diggles, Linda E.; MacDonald, Lawrence; Iwanczyk, Jan S.; Mishkin, Fred S.; Khalkhali, Iraj
2003-01-01
99mTc-sestamibi scintimammography (SMM) is a useful adjunct to conventional X-ray mammography (XMM) for the assessment of breast cancer. An increasing number of studies has emphasized fair sensitivity values for the detection of tumors >1 cm, compared to XMM, particularly in situations where high glandular breast densities make mammographic interpretation difficult. In addition, SMM has demonstrated high specificity for cancer, compared to various functional and anatomic imaging modalities. However, large field-of-view (FOV) gamma cameras are difficult to position close to the breasts, which decreases spatial resolution and subsequently, the sensitivity of detection for tumors <1 cm. New dedicated detectors featuring small FOV and increased spatial resolution have recently been developed. In this setting, improvement in tumor detection sensitivity, particularly with regard to small cancers is expected. At Division of Nuclear Medicine, Harbor-UCLA Medical Center, we have performed over 2000 SMM within the last 9 years. We have recently used a dedicated breast camera (LumaGEM™) featuring a 12.8×12.8 cm 2 FOV and an array of 2×2×6 mm 3 discrete crystals coupled to a photon-sensitive photomultiplier tube readout. This camera is mounted on a mammography gantry allowing upright imaging, medial positioning and use of breast compression. Preliminary data indicates significant enhancement of spatial resolution by comparison with standard imaging in the first 10 patients. Larger series will be needed to conclude on sensitivity/specificity issues.
Real-time imaging of methane gas leaks using a single-pixel camera.
Gibson, Graham M; Sun, Baoqing; Edgar, Matthew P; Phillips, David B; Hempler, Nils; Maker, Gareth T; Malcolm, Graeme P A; Padgett, Miles J
2017-02-20
We demonstrate a camera which can image methane gas at video rates, using only a single-pixel detector and structured illumination. The light source is an infrared laser diode operating at 1.651μm tuned to an absorption line of methane gas. The light is structured using an addressable micromirror array to pattern the laser output with a sequence of Hadamard masks. The resulting backscattered light is recorded using a single-pixel InGaAs detector which provides a measure of the correlation between the projected patterns and the gas distribution in the scene. Knowledge of this correlation and the patterns allows an image to be reconstructed of the gas in the scene. For the application of locating gas leaks the frame rate of the camera is of primary importance, which in this case is inversely proportional to the square of the linear resolution. Here we demonstrate gas imaging at ~25 fps while using 256 mask patterns (corresponding to an image resolution of 16×16). To aid the task of locating the source of the gas emission, we overlay an upsampled and smoothed image of the low-resolution gas image onto a high-resolution color image of the scene, recorded using a standard CMOS camera. We demonstrate for an illumination of only 5mW across the field-of-view imaging of a methane gas leak of ~0.2 litres/minute from a distance of ~1 metre.
Improved camera for better X-ray powder photographs
NASA Technical Reports Server (NTRS)
Parrish, W.; Vajda, I. E.
1969-01-01
Camera obtains powder-type photographs of single crystals or polycrystalline powder specimens. X-ray diffraction photographs of a powder specimen are characterized by improved resolution and greater intensity. A reasonably good powder pattern of small samples can be produced for identification purposes.
Developing a CCD camera with high spatial resolution for RIXS in the soft X-ray range
NASA Astrophysics Data System (ADS)
Soman, M. R.; Hall, D. J.; Tutt, J. H.; Murray, N. J.; Holland, A. D.; Schmitt, T.; Raabe, J.; Schmitt, B.
2013-12-01
The Super Advanced X-ray Emission Spectrometer (SAXES) at the Swiss Light Source contains a high resolution Charge-Coupled Device (CCD) camera used for Resonant Inelastic X-ray Scattering (RIXS). Using the current CCD-based camera system, the energy-dispersive spectrometer has an energy resolution (E/ΔE) of approximately 12,000 at 930 eV. A recent study predicted that through an upgrade to the grating and camera system, the energy resolution could be improved by a factor of 2. In order to achieve this goal in the spectral domain, the spatial resolution of the CCD must be improved to better than 5 μm from the current 24 μm spatial resolution (FWHM). The 400 eV-1600 eV energy X-rays detected by this spectrometer primarily interact within the field free region of the CCD, producing electron clouds which will diffuse isotropically until they reach the depleted region and buried channel. This diffusion of the charge leads to events which are split across several pixels. Through the analysis of the charge distribution across the pixels, various centroiding techniques can be used to pinpoint the spatial location of the X-ray interaction to the sub-pixel level, greatly improving the spatial resolution achieved. Using the PolLux soft X-ray microspectroscopy endstation at the Swiss Light Source, a beam of X-rays of energies from 200 eV to 1400 eV can be focused down to a spot size of approximately 20 nm. Scanning this spot across the 16 μm square pixels allows the sub-pixel response to be investigated. Previous work has demonstrated the potential improvement in spatial resolution achievable by centroiding events in a standard CCD. An Electron-Multiplying CCD (EM-CCD) has been used to improve the signal to effective readout noise ratio achieved resulting in a worst-case spatial resolution measurement of 4.5±0.2 μm and 3.9±0.1 μm at 530 eV and 680 eV respectively. A method is described that allows the contribution of the X-ray spot size to be deconvolved from these worst-case resolution measurements, estimating the spatial resolution to be approximately 3.5 μm and 3.0 μm at 530 eV and 680 eV, well below the resolution limit of 5 μm required to improve the spectral resolution by a factor of 2.
The iQID Camera: An Ionizing-Radiation Quantum Imaging Detector
Miller, Brian W.; Gregory, Stephanie J.; Fuller, Erin S.; ...
2014-06-11
We have developed and tested a novel, ionizing-radiation Quantum Imaging Detector (iQID). This scintillation-based detector was originally developed as a high-resolution gamma-ray imager, called BazookaSPECT, for use in single-photon emission computed tomography (SPECT). Recently, we have investigated the detectors response and imaging potential with other forms of ionizing radiation including alpha, neutron, beta, and fission fragment particles. The detector’s response to a broad range of ionizing radiation has prompted its new title. The principle operation of the iQID camera involves coupling a scintillator to an image intensifier. The scintillation light generated particle interactions is optically amplified by the intensifier andmore » then re-imaged onto a CCD/CMOS camera sensor. The intensifier provides sufficient optical gain that practically any CCD/CMOS camera can be used to image ionizing radiation. Individual particles are identified and their spatial position (to sub-pixel accuracy) and energy are estimated on an event-by-event basis in real time using image analysis algorithms on high-performance graphics processing hardware. Distinguishing features of the iQID camera include portability, large active areas, high sensitivity, and high spatial resolution (tens of microns). Although modest, iQID has energy resolution that is sufficient to discrimate between particles. Additionally, spatial features of individual events can be used for particle discrimination. An important iQID imaging application that has recently been developed is single-particle, real-time digital autoradiography. In conclusion, we present the latest results and discuss potential applications.« less
Cooperative multisensor system for real-time face detection and tracking in uncontrolled conditions
NASA Astrophysics Data System (ADS)
Marchesotti, Luca; Piva, Stefano; Turolla, Andrea; Minetti, Deborah; Regazzoni, Carlo S.
2005-03-01
The presented work describes an innovative architecture for multi-sensor distributed video surveillance applications. The aim of the system is to track moving objects in outdoor environments with a cooperative strategy exploiting two video cameras. The system also exhibits the capacity of focusing its attention on the faces of detected pedestrians collecting snapshot frames of face images, by segmenting and tracking them over time at different resolution. The system is designed to employ two video cameras in a cooperative client/server structure: the first camera monitors the entire area of interest and detects the moving objects using change detection techniques. The detected objects are tracked over time and their position is indicated on a map representing the monitored area. The objects" coordinates are sent to the server sensor in order to point its zooming optics towards the moving object. The second camera tracks the objects at high resolution. As well as the client camera, this sensor is calibrated and the position of the object detected on the image plane reference system is translated in its coordinates referred to the same area map. In the map common reference system, data fusion techniques are applied to achieve a more precise and robust estimation of the objects" track and to perform face detection and tracking. The work novelties and strength reside in the cooperative multi-sensor approach, in the high resolution long distance tracking and in the automatic collection of biometric data such as a person face clip for recognition purposes.
Expanded opportunities of THz passive camera for the detection of concealed objects
NASA Astrophysics Data System (ADS)
Trofimov, Vyacheslav A.; Trofimov, Vladislav V.; Kuchik, Igor E.
2013-10-01
Among the security problems, the detection of object implanted into either the human body or animal body is the urgent problem. At the present time the main tool for the detection of such object is X-raying only. However, X-ray is the ionized radiation and therefore can not be used often. Other way for the problem solving is passive THz imaging using. In our opinion, using of the passive THz camera may help to detect the object implanted into the human body under certain conditions. The physical reason of such possibility arises from temperature trace on the human skin as a result of the difference in temperature between object and parts of human body. Modern passive THz cameras have not enough resolution in temperature to see this difference. That is why, we use computer processing to enhance the passive THz camera resolution for this application. After computer processing of images captured by passive THz camera TS4, developed by ThruVision Systems Ltd., we may see the pronounced temperature trace on the human body skin from the water, which is drunk by person, or other food eaten by person. Nevertheless, there are many difficulties on the way of full soution of this problem. We illustrate also an improvement of quality of the image captured by comercially available passive THz cameras using computer processing. In some cases, one can fully supress a noise on the image without loss of its quality. Using computer processing of the THz image of objects concealed on the human body, one may improve it many times. Consequently, the instrumental resolution of such device may be increased without any additional engineering efforts.
Performance benefits and limitations of a camera network
NASA Astrophysics Data System (ADS)
Carr, Peter; Thomas, Paul J.; Hornsey, Richard
2005-06-01
Visual information is of vital significance to both animals and artificial systems. The majority of mammals rely on two images, each with a resolution of 107-108 'pixels' per image. At the other extreme are insect eyes where the field of view is segmented into 103-105 images, each comprising effectively one pixel/image. The great majority of artificial imaging systems lie nearer to the mammalian characteristics in this parameter space, although electronic compound eyes have been developed in this laboratory and elsewhere. If the definition of a vision system is expanded to include networks or swarms of sensor elements, then schools of fish, flocks of birds and ant or termite colonies occupy a region where the number of images and the pixels/image may be comparable. A useful system might then have 105 imagers, each with about 104-105 pixels. Artificial analogs to these situations include sensor webs, smart dust and co-ordinated robot clusters. As an extreme example, we might consider the collective vision system represented by the imminent existence of ~109 cellular telephones, each with a one-megapixel camera. Unoccupied regions in this resolution-segmentation parameter space suggest opportunities for innovative artificial sensor network systems. Essential for the full exploitation of these opportunities is the availability of custom CMOS image sensor chips whose characteristics can be tailored to the application. Key attributes of such a chip set might include integrated image processing and control, low cost, and low power. This paper compares selected experimentally determined system specifications for an inward-looking array of 12 cameras with the aid of a camera-network model developed to explore the tradeoff between camera resolution and the number of cameras.
The Atlases of Vesta derived from Dawn Framing Camera images
NASA Astrophysics Data System (ADS)
Roatsch, T.; Kersten, E.; Matz, K.; Preusker, F.; Scholten, F.; Jaumann, R.; Raymond, C. A.; Russell, C. T.
2013-12-01
The Dawn Framing Camera acquired during its two HAMO (High Altitude Mapping Orbit) phases in 2011 and 2012 about 6,000 clear filter images with a resolution of about 60 m/pixel. We combined these images in a global ortho-rectified mosaic of Vesta (60 m/pixel resolution). Only very small areas near the northern pole were still in darkness and are missing in the mosaic. The Dawn Framing Camera also acquired about 10,000 high-resolution clear filter images (about 20 m/pixel) of Vesta during its Low Altitude Mapping Orbit (LAMO). Unfortunately, the northern part of Vesta was still in darkness during this phase, good illumination (incidence angle < 70°) was only available for 66.8 % of the surface [1]. We used the LAMO images to calculate another global mosaic of Vesta, this time with 20 m/pixel resolution. Both global mosaics were used to produce atlases of Vesta: a HAMO atlas with 15 tiles at a scale of 1:500,000 and a LAMO atlas with 30 tiles at a scale between 1:200,000 and 1:225,180. The nomenclature used in these atlases is based on names and places historically associated with the Roman goddess Vesta, and is compliant with the rules of the IAU. 65 names for geological features were already approved by the IAU, 39 additional names are currently under review. Selected examples of both atlases will be shown in this presentation. Reference: [1]Roatsch, Th., etal., High-resolution Vesta Low Altitude Mapping Orbit Atlas derived from Dawn Framing Camera images. Planetary and Space Science (2013), http://dx.doi.org/10.1016/j.pss.2013.06.024i
CMOS Camera Array With Onboard Memory
NASA Technical Reports Server (NTRS)
Gat, Nahum
2009-01-01
A compact CMOS (complementary metal oxide semiconductor) camera system has been developed with high resolution (1.3 Megapixels), a USB (universal serial bus) 2.0 interface, and an onboard memory. Exposure times, and other operating parameters, are sent from a control PC via the USB port. Data from the camera can be received via the USB port and the interface allows for simple control and data capture through a laptop computer.
Solid State Television Camera (CID)
NASA Technical Reports Server (NTRS)
Steele, D. W.; Green, W. T.
1976-01-01
The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.
Photogrammetry of Apollo 15 photography, part C
NASA Technical Reports Server (NTRS)
Wu, S. S. C.; Schafer, F. J.; Jordan, R.; Nakata, G. M.; Derick, J. L.
1972-01-01
In the Apollo 15 mission, a mapping camera system and a 61 cm optical bar, high resolution panoramic camera, as well as a laser altimeter were used. The panoramic camera is described, having several distortion sources, such as cylindrical shape of the negative film surface, the scanning action of the lens, the image motion compensator, and the spacecraft motion. Film products were processed on a specifically designed analytical plotter.
Return Beam Vidicon (RBV) panchromatic two-camera subsystem for LANDSAT-C
NASA Technical Reports Server (NTRS)
1977-01-01
A two-inch Return Beam Vidicon (RBV) panchromatic two camera Subsystem, together with spare components was designed and fabricated for the LANDSAT-C Satellite; the basis for the design was the Landsat 1&2 RBV Camera System. The purpose of the RBV Subsystem is to acquire high resolution pictures of the Earth for a mapping application. Where possible, residual LANDSAT 1 and 2 equipment was utilized.
A system for extracting 3-dimensional measurements from a stereo pair of TV cameras
NASA Technical Reports Server (NTRS)
Yakimovsky, Y.; Cunningham, R.
1976-01-01
Obtaining accurate three-dimensional (3-D) measurement from a stereo pair of TV cameras is a task requiring camera modeling, calibration, and the matching of the two images of a real 3-D point on the two TV pictures. A system which models and calibrates the cameras and pairs the two images of a real-world point in the two pictures, either manually or automatically, was implemented. This system is operating and provides three-dimensional measurements resolution of + or - mm at distances of about 2 m.
Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C
2012-01-01
Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.
Real time moving scene holographic camera system
NASA Technical Reports Server (NTRS)
Kurtz, R. L. (Inventor)
1973-01-01
A holographic motion picture camera system producing resolution of front surface detail is described. The system utilizes a beam of coherent light and means for dividing the beam into a reference beam for direct transmission to a conventional movie camera and two reflection signal beams for transmission to the movie camera by reflection from the front side of a moving scene. The system is arranged so that critical parts of the system are positioned on the foci of a pair of interrelated, mathematically derived ellipses. The camera has the theoretical capability of producing motion picture holograms of projectiles moving at speeds as high as 900,000 cm/sec (about 21,450 mph).
Li, Tian-Jiao; Li, Sai; Yuan, Yuan; Liu, Yu-Dong; Xu, Chuan-Long; Shuai, Yong; Tan, He-Ping
2017-04-03
Plenoptic cameras are used for capturing flames in studies of high-temperature phenomena. However, simulations of plenoptic camera models can be used prior to the experiment improve experimental efficiency and reduce cost. In this work, microlens arrays, which are based on the established light field camera model, are optimized into a hexagonal structure with three types of microlenses. With this improved plenoptic camera model, light field imaging of static objects and flame are simulated using the calibrated parameters of the Raytrix camera (R29). The optimized models improve the image resolution, imaging screen utilization, and shooting range of depth of field.
Extreme ultra-violet movie camera for imaging microsecond time scale magnetic reconnection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chai, Kil-Byoung; Bellan, Paul M.
2013-12-15
An ultra-fast extreme ultra-violet (EUV) movie camera has been developed for imaging magnetic reconnection in the Caltech spheromak/astrophysical jet experiment. The camera consists of a broadband Mo:Si multilayer mirror, a fast decaying YAG:Ce scintillator, a visible light block, and a high-speed visible light CCD camera. The camera can capture EUV images as fast as 3.3 × 10{sup 6} frames per second with 0.5 cm spatial resolution. The spectral range is from 20 eV to 60 eV. EUV images reveal strong, transient, highly localized bursts of EUV radiation when magnetic reconnection occurs.
Television camera as a scientific instrument
NASA Technical Reports Server (NTRS)
Smokler, M. I.
1970-01-01
Rigorous calibration program, coupled with a sophisticated data-processing program that introduced compensation for system response to correct photometry, geometric linearity, and resolution, converted a television camera to a quantitative measuring instrument. The output data are in the forms of both numeric printout records and photographs.
Low-cost conversion of the Polaroid MD-4 land camera to a digital gel documentation system.
Porch, Timothy G; Erpelding, John E
2006-04-30
A simple, inexpensive design is presented for the rapid conversion of the popular MD-4 Polaroid land camera to a high quality digital gel documentation system. Images of ethidium bromide stained DNA gels captured using the digital system were compared to images captured on Polaroid instant film. Resolution and sensitivity were enhanced using the digital system. In addition to the low cost and superior image quality of the digital system, there is also the added convenience of real-time image viewing through the swivel LCD of the digital camera, wide flexibility of gel sizes, accurate automatic focusing, variable image resolution, and consistent ease of use and quality. Images can be directly imported to a computer by using the USB port on the digital camera, further enhancing the potential of the digital system for documentation, analysis, and archiving. The system is appropriate for use as a start-up gel documentation system and for routine gel analysis.
Optical performance analysis of plenoptic camera systems
NASA Astrophysics Data System (ADS)
Langguth, Christin; Oberdörster, Alexander; Brückner, Andreas; Wippermann, Frank; Bräuer, Andreas
2014-09-01
Adding an array of microlenses in front of the sensor transforms the capabilities of a conventional camera to capture both spatial and angular information within a single shot. This plenoptic camera is capable of obtaining depth information and providing it for a multitude of applications, e.g. artificial re-focusing of photographs. Without the need of active illumination it represents a compact and fast optical 3D acquisition technique with reduced effort in system alignment. Since the extent of the aperture limits the range of detected angles, the observed parallax is reduced compared to common stereo imaging systems, which results in a decreased depth resolution. Besides, the gain of angular information implies a degraded spatial resolution. This trade-off requires a careful choice of the optical system parameters. We present a comprehensive assessment of possible degrees of freedom in the design of plenoptic systems. Utilizing a custom-built simulation tool, the optical performance is quantified with respect to particular starting conditions. Furthermore, a plenoptic camera prototype is demonstrated in order to verify the predicted optical characteristics.
Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Slit-Jaw Imaging System
NASA Astrophysics Data System (ADS)
Wilkerson, P.; Champey, P. R.; Winebarger, A. R.; Kobayashi, K.; Savage, S. L.
2017-12-01
The Marshall Grazing Incidence X-ray Spectrometer is a NASA sounding rocket payload providing a 0.6 - 2.5 nm spectrum with unprecedented spatial and spectral resolution. The instrument is comprised of a novel optical design, featuring a Wolter1 grazing incidence telescope, which produces a focused solar image on a slit plate, an identical pair of stigmatic optics, a planar diffraction grating and a low-noise detector. When MaGIXS flies on a suborbital launch in 2019, a slit-jaw camera system will reimage the focal plane of the telescope providing a reference for pointing the telescope on the solar disk and aligning the data to supporting observations from satellites and other rockets. The telescope focuses the X-ray and EUV image of the sun onto a plate covered with a phosphor coating that absorbs EUV photons, which then fluoresces in visible light. This 10-week REU project was aimed at optimizing an off-axis mounted camera with 600-line resolution NTSC video for extremely low light imaging of the slit plate. Radiometric calculations indicate an intensity of less than 1 lux at the slit jaw plane, which set the requirement for camera sensitivity. We selected a Watec 910DB EIA charge-coupled device (CCD) monochrome camera, which has a manufacturer quoted sensitivity of 0.0001 lux at F1.2. A high magnification and low distortion lens was then identified to image the slit jaw plane from a distance of approximately 10 cm. With the selected CCD camera, tests show that at extreme low-light levels, we achieve a higher resolution than expected, with only a moderate drop in frame rate. Based on sounding rocket flight heritage, the launch vehicle attitude control system is known to stabilize the instrument pointing such that jitter does not degrade video quality for context imaging. Future steps towards implementation of the imaging system will include ruggedizing the flight camera housing and mounting the selected camera and lens combination to the instrument structure.
Penna, Rachele R; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M
2017-01-01
To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes.
Penna, Rachele R.; de Sanctis, Ugo; Catalano, Martina; Brusasco, Luca; Grignolo, Federico M.
2017-01-01
AIM To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. CONCLUSION As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes. PMID:28393039
High spatial resolution infrared camera as ISS external experiment
NASA Astrophysics Data System (ADS)
Eckehard, Lorenz; Frerker, Hap; Fitch, Robert Alan
High spatial resolution infrared camera as ISS external experiment for monitoring global climate changes uses ISS internal and external resources (eg. data storage). The optical experiment will consist of an infrared camera for monitoring global climate changes from the ISS. This technology was evaluated by the German small satellite mission BIRD and further developed in different ESA projects. Compared to BIRD the presended instrument uses proven sensor advanced technologies (ISS external) and ISS on board processing and storage capabili-ties (internal). The instrument will be equipped with a serial interfaces for TM/TC and several relay commands for the power supply. For data processing and storage a mass memory is re-quired. The access to actual attitude data is highly desired to produce geo referenced maps-if possible by an on board processing.
NASA Astrophysics Data System (ADS)
Oertel, D.; Jahn, H.; Sandau, R.; Walter, I.; Driescher, H.
1990-10-01
Objectives of the multifunctional stereo imaging camera (MUSIC) system to be deployed on the Soviet Mars-94 mission are outlined. A high-resolution stereo camera (HRSC) and wide-angle opto-electronic stereo scanner (WAOSS) are combined in terms of hardware, software, technology aspects, and solutions. Both HRSC and WAOSS are push-button instruments containing a single optical system and focal plates with several parallel CCD line sensors. Emphasis is placed on the MUSIC system's stereo capability, its design, mass memory, and data compression. A 1-Gbit memory is divided into two parts: 80 percent for HRSC and 20 percent for WAOSS, while the selected on-line compression strategy is based on macropixel coding and real-time transform coding.
Image intensification; Proceedings of the Meeting, Los Angeles, CA, Jan. 17, 18, 1989
NASA Astrophysics Data System (ADS)
Csorba, Illes P.
Various papers on image intensification are presented. Individual topics discussed include: status of high-speed optical detector technologies, super second generation imge intensifier, gated image intensifiers and applications, resistive-anode position-sensing photomultiplier tube operational modeling, undersea imaging and target detection with gated image intensifier tubes, image intensifier modules for use with commercially available solid state cameras, specifying the components of an intensified solid state television camera, superconducting IR focal plane arrays, one-inch TV camera tube with very high resolution capacity, CCD-Digicon detector system performance parameters, high-resolution X-ray imaging device, high-output technology microchannel plate, preconditioning of microchannel plate stacks, recent advances in small-pore microchannel plate technology, performance of long-life curved channel microchannel plates, low-noise microchannel plates, development of a quartz envelope heater.
NASA Astrophysics Data System (ADS)
Mia, Mozammel; Al Bashir, Mahmood; Dhar, Nikhil Ranjan
2016-10-01
Hard turning is increasingly employed in machining, lately, to replace time-consuming conventional turning followed by grinding process. An excessive amount of tool wear in hard turning is one of the main hurdles to be overcome. Many researchers have developed tool wear model, but most of them developed it for a particular work-tool-environment combination. No aggregate model is developed that can be used to predict the amount of principal flank wear for specific machining time. An empirical model of principal flank wear (VB) has been developed for the different hardness of workpiece (HRC40, HRC48 and HRC56) while turning by coated carbide insert with different configurations (SNMM and SNMG) under both dry and high pressure coolant conditions. Unlike other developed model, this model includes the use of dummy variables along with the base empirical equation to entail the effect of any changes in the input conditions on the response. The base empirical equation for principal flank wear is formulated adopting the Exponential Associate Function using the experimental results. The coefficient of dummy variable reflects the shifting of the response from one set of machining condition to another set of machining condition which is determined by simple linear regression. The independent cutting parameters (speed, rate, depth of cut) are kept constant while formulating and analyzing this model. The developed model is validated with different sets of machining responses in turning hardened medium carbon steel by coated carbide inserts. For any particular set, the model can be used to predict the amount of principal flank wear for specific machining time. Since the predicted results exhibit good resemblance with experimental data and the average percentage error is <10 %, this model can be used to predict the principal flank wear for stated conditions.
A comparison of roughness parameters and friction coefficients of aesthetic archwires.
Rudge, Philippa; Sherriff, Martyn; Bister, Dirk
2015-02-01
Compare surface roughness of 'aesthetic' nickel-titanium (NiTi) archwires with their dynamic frictional properties. Archwires investigated were: four fully coated tooth coloured [Forestadent: Biocosmetic (FB) and Titanol Cosmetic (FT); TOC Tooth Tone (TT); and Hawley Russell Coated Superelastic NiTi (HRC)]; two partially coated tooth coloured [DB Euroline Microcoated (DB) and TP Aesthetic NiTi (TP)]; two rhodium coated [TOC Sentalloy (TS) and Hawley Russell Rhodium Coated Superelastic NiTi (HRR)]; and two controls: stainless steel [Forestadent Steel (FS)] and NiTi archwire [Forestadent Titanol Superelastic (FN)]. Surface roughness [profilometry (Rugosurf)] was compared with frictional coefficients for archwire/bracket/ligature combinations (n = 10). Analysis of variance, Sidak's multiple comparison of means, and Spearman's correlation coefficient were used for analysis. Roughness coefficients were from low to high: FB; FN; TT; FS; TS; HRR; FT; DB; TP; HRC. Friction coefficients were from low to high: TP; FS; FN; HRR; FT; DB; FB; HRC; TS; TT. Coated archwires generally exhibited higher friction than uncoated controls. TP had the lowest friction but this was not statistically significant (P < 0.05). Friction of tooth coloured coated archwires were significantly different for some wires. Spearman's correlation did not demonstrate consistency between surface roughness (R a) and dynamic friction. Aesthetic archwires investigated had either low surface roughness or low frictional resistance but not both properties simultaneously. Causes for friction are likely to be multifactorial and do not appear to be solely determined by surface roughness (measured by profilometry). For selecting the most appropriate aligning archwire, both surface roughness and frictional resistance need to be considered. © The Author 2014. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Li, Yu-rong; Cui, Yi-ping; Ji, Zhi-yuan; Cai, Lu-lu; Zou, Hua-song; Hutchins, William C.; Yang, Ching-hong; Chen, Gong-you
2012-01-01
Fructose-bisphophate aldolase (FbaB), is an enzyme in glycolysis and gluconeogenesis in living organisms. The mutagenesis in a unique fbaB gene of Xanthomonas oryzae pv. oryzicola, the causal agent of rice bacterial leaf streak, led the pathogen not only unable to use pyruvate and malate for growth and delayed its growth when fructose was used as the sole carbon source, but also reduced extracellular polysaccharide (EPS) production and impaired bacterial virulence and growth in rice. Intriguingly, the fbaB promoter contains an imperfect PIP-box (plant-inducible promoter) (TTCGT-N9-TTCGT). The expression of fbaB was negatively regulated by a key hrp regulatory HrpG and HrpX cascade. Base substitution in the PIP-box altered the regulation of fbaB with the cascade. Furthermore, the expression of fbaB in X. oryzae pv. oryzicola RS105 strain was inducible in planta rather than in a nutrient-rich medium. Except other hrp-hrc-hpa genes, the expression of hrpG and hrpX was repressed and the transcripts of hrcC, hrpE and hpa3 were enhanced when fbaB was deleted. The mutation in hrcC, hrpE or hpa3 reduced the ability of the pathogen to acquire pyruvate and malate. In addition, bacterial virulence and growth in planta and EPS production in RΔfbaB mutant were completely restored to the wild-type level by the presence of fbaB in trans. This is the first report to demonstrate that carbohydrates, assimilated by X. oryzae pv. oryzicola, play critical roles in coordinating hrp gene expression through a yet unknown regulator. PMID:22384086
Upgrading and testing program for narrow band high resolution planetary IR imaging spectrometer
NASA Technical Reports Server (NTRS)
Wattson, R. B.; Rappaport, S.
1977-01-01
An imaging spectrometer, intended primarily for observations of the outer planets, which utilizes an acoustically tuned optical filter (ATOF) and a charge coupled device (CCD) television camera was modified to improve spatial resolution and sensitivity. The upgraded instrument was a spatial resolving power of approximately 1 arc second, as defined by an f/7 beam at the CCD position and it has this resolution over the 50 arc second field of view. Less vignetting occurs and sensitivity is four times greater. The spectral resolution of 15 A over the wavelength interval 6500 A - 11,000 A is unchanged. Mechanical utility has been increased by the use of a honeycomb optical table, mechanically rigid yet adjustable optical component mounts, and a camera focus translation stage. The upgraded instrument was used to observe Venus and Saturn.
Wei, Wanchun; Broussard, Leah J.; Hoffbauer, Mark Arles; ...
2016-05-16
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15μm has been achieved, which is equivalent to a UCN energy resolution below 2 pico-electron-volts through the relation δE=m 0gδx. Here, the symbols δE, δx, m 0 and g are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. Asmore » a result, this method allows different types of UCN spectroscopy and other applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei, Wanchun; Broussard, Leah J.; Hoffbauer, Mark Arles
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15μm has been achieved, which is equivalent to a UCN energy resolution below 2 pico-electron-volts through the relation δE=m 0gδx. Here, the symbols δE, δx, m 0 and g are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. Asmore » a result, this method allows different types of UCN spectroscopy and other applications.« less
Super resolution PLIF demonstrated in turbulent jet flows seeded with I2
NASA Astrophysics Data System (ADS)
Xu, Wenjiang; Liu, Ning; Ma, Lin
2018-05-01
Planar laser induced fluorescence (PLIF) represents an indispensable tool for flow and flame imaging. However, the PLIF technique suffers from limited spatial resolution or blurring in many situations, which restricts its applicability and capability. This work describes a new method, named SR-PLIF (super-resolution PLIF), to overcome these limitations and enhance the capability of PLIF. The method uses PLIF images captured simultaneously from two (or more) orientations to reconstruct a final PLIF image with resolution enhanced or blurring removed. This paper reports the development of the reconstruction algorithm, and the experimental demonstration of the SR-PLIF method both with controlled samples and with turbulent flows seeded with iodine vapor. Using controlled samples with two cameras, the spatial resolution in the best case was improved from 0.06 mm in the projections to 0.03 mm in the SR image, in terms of the spreading width of a sharp edge. With turbulent flows, an image sharpness measure was developed to quantify the spatial resolution, and SR reconstruction with two cameras can effectively improve the spatial resolution compared to the projections in terms of the sharpness measure.
In-air versus underwater comparison of 3D reconstruction accuracy using action sport cameras.
Bernardina, Gustavo R D; Cerveri, Pietro; Barros, Ricardo M L; Marins, João C B; Silvatti, Amanda P
2017-01-25
Action sport cameras (ASC) have achieved a large consensus for recreational purposes due to ongoing cost decrease, image resolution and frame rate increase, along with plug-and-play usability. Consequently, they have been recently considered for sport gesture studies and quantitative athletic performance evaluation. In this paper, we evaluated the potential of two ASCs (GoPro Hero3+) for in-air (laboratory) and underwater (swimming pool) three-dimensional (3D) motion analysis as a function of different camera setups involving the acquisition frequency, image resolution and field of view. This is motivated by the fact that in swimming, movement cycles are characterized by underwater and in-air phases what imposes the technical challenge of having a split volume configuration: an underwater measurement volume observed by underwater cameras and an in-air measurement volume observed by in-air cameras. The reconstruction of whole swimming cycles requires thus merging of simultaneous measurements acquired in both volumes. Characterizing and optimizing the instrumental errors of such a configuration makes mandatory the assessment of the instrumental errors of both volumes. In order to calibrate the camera stereo pair, black spherical markers placed on two calibration tools, used both in-air and underwater, and a two-step nonlinear optimization were exploited. The 3D reconstruction accuracy of testing markers and the repeatability of the estimated camera parameters accounted for system performance. For both environments, statistical tests were focused on the comparison of the different camera configurations. Then, each camera configuration was compared across the two environments. In all assessed resolutions, and in both environments, the reconstruction error (true distance between the two testing markers) was less than 3mm and the error related to the working volume diagonal was in the range of 1:2000 (3×1.3×1.5m 3 ) to 1:7000 (4.5×2.2×1.5m 3 ) in agreement with the literature. Statistically, the 3D accuracy obtained in the in-air environment was poorer (p<10 -5 ) than the one in the underwater environment, across all the tested camera configurations. Related to the repeatability of the camera parameters, we found a very low variability in both environments (1.7% and 2.9%, in-air and underwater). This result encourage the use of ASC technology to perform quantitative reconstruction both in-air and underwater environments. Copyright © 2016 Elsevier Ltd. All rights reserved.
Remote Sensing Simulation Activities for Earthlings
ERIC Educational Resources Information Center
Krockover, Gerald H.; Odden, Thomas D.
1977-01-01
Suggested are activities using a Polaroid camera to illustrate the capabilities of remote sensing. Reading materials from the National Aeronautics and Space Administration (NASA) are suggested. Methods for (1) finding a camera's focal length, (2) calculating ground dimension photograph simulation, and (3) limiting size using film resolution are…
ERIC Educational Resources Information Center
Reynolds, Ronald F.
1984-01-01
Describes the basic components of a space telescope that will be launched during a 1986 space shuttle mission. These components include a wide field/planetary camera, faint object spectroscope, high-resolution spectrograph, high-speed photometer, faint object camera, and fine guidance sensors. Data to be collected from these instruments are…
A high resolution IR/visible imaging system for the W7-X limiter
NASA Astrophysics Data System (ADS)
Wurden, G. A.; Stephey, L. A.; Biedermann, C.; Jakubowski, M. W.; Dunn, J. P.; Gamradt, M.
2016-11-01
A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphite tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (˜1-4.5 MW/m2), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO's can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.
A high resolution IR/visible imaging system for the W7-X limiter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wurden, G. A., E-mail: wurden@lanl.gov; Dunn, J. P.; Stephey, L. A.
A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphitemore » tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (∼1–4.5 MW/m{sup 2}), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO’s can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.« less
CHANDRA AND SWIFT X-RAY OBSERVATIONS OF THE X-RAY PULSAR SMC X-2 DURING THE OUTBURST OF 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, K. L.; Hu, C.-P; Lin, L. C. C.
2016-09-10
We report the Chandra /HRC-S and Swift /XRT observations for the 2015 outburst of the high-mass X-ray binary pulsar in the Small Magellanic Cloud, SMC X-2. While previous studies suggested that either an O star or a Be star in the field is the high-mass companion of SMC X-2, our Chandra /HRC-S image unambiguously confirms the O-type star as the true optical counterpart. Using the Swift /XRT observations, we extracted accurate orbital parameters of the pulsar binary through a time of arrivals analysis. In addition, there were two X-ray dips near the inferior conjunction, which are possibly caused by eclipsesmore » or an ionized high-density shadow wind near the companion’s surface. Finally, we propose that an outflow driven by the radiation pressure from day ∼10 played an important role in the X-ray/optical evolution of the outburst.« less
NASA Astrophysics Data System (ADS)
Fang, Yuanbin; Sha, Hongwei; Yu, Yunmin; Chen, Bing
2018-03-01
Material composition, hardness and wear properties of the throw-out plate improved are analysed on a road milling machine. At the same time, analyse the tissue and performance of Fe based alloy named Fe60 cladding layer using the plasma surfacing method. And the original and improved throw-out plates are analysed throwing material effect by the dynamic analysis. Then the throw-out plate samples are verified. The results show that Fe60 powder is selected as surface strengthening material. By the improved structure, the hardness of the throw-out plate increases from 14.6HRC to 57.5HRC, and the wear resistance increases from 0.452g-1 to 16.393g-1. At the same time, it increases from 3263 to 3433 to fall into the collecting material number of milling machine. It provides important guidance for structure design and process design of the milling machine throw-out plate.
External Mask Based Depth and Light Field Camera
2013-12-08
laid out in the previous light field cameras. A good overview of the sampling of the plenoptic function can be found in the survey work by Wetzstein et...view is shown in Figure 6. 5. Applications High spatial resolution depth and light fields are a rich source of information about the plenoptic ...http://www.pelicanimaging.com/. [4] E. Adelson and J. Wang. Single lens stereo with a plenoptic camera. Pattern Analysis and Machine Intelligence
HST Solar Arrays photographed by Electronic Still Camera
NASA Technical Reports Server (NTRS)
1993-01-01
This medium close-up view of one of two original Solar Arrays (SA) on the Hubble Space Telescope (HST) was photographed with an Electronic Still Camera (ESC), and downlinked to ground controllers soon afterward. This view shows the cell side of the minus V-2 panel. Electronic still photography is a technology which provides the means for a handheld camera to electronically capture and digitize an image with resolution approaching film quality.
NASA Astrophysics Data System (ADS)
Lojacono, Xavier; Richard, Marie-Hélène; Ley, Jean-Luc; Testa, Etienne; Ray, Cédric; Freud, Nicolas; Létang, Jean Michel; Dauvergne, Denis; Maxim, Voichiţa; Prost, Rémy
2013-10-01
The Compton camera is a relevant imaging device for the detection of prompt photons produced by nuclear fragmentation in hadrontherapy. It may allow an improvement in detection efficiency compared to a standard gamma-camera but requires more sophisticated image reconstruction techniques. In this work, we simulate low statistics acquisitions from a point source having a broad energy spectrum compatible with hadrontherapy. We then reconstruct the image of the source with a recently developed filtered backprojection algorithm, a line-cone approach and an iterative List Mode Maximum Likelihood Expectation Maximization algorithm. Simulated data come from a Compton camera prototype designed for hadrontherapy online monitoring. Results indicate that the achievable resolution in directions parallel to the detector, that may include the beam direction, is compatible with the quality control requirements. With the prototype under study, the reconstructed image is elongated in the direction orthogonal to the detector. However this direction is of less interest in hadrontherapy where the first requirement is to determine the penetration depth of the beam in the patient. Additionally, the resolution may be recovered using a second camera.
Zhu, Banghe; Rasmussen, John C.; Litorja, Maritoni
2017-01-01
To date, no emerging preclinical or clinical near-infrared fluorescence (NIRF) imaging devices for non-invasive and/or surgical guidance have their performances validated on working standards with SI units of radiance that enable comparison or quantitative quality assurance. In this work, we developed and deployed a methodology to calibrate a stable, solid phantom for emission radiance with units of mW · sr−1 · cm−2 for use in characterizing the measurement sensitivity of ICCD and IsCMOS detection, signal-to-noise ratio, and contrast. In addition, at calibrated radiances, we assess transverse and lateral resolution of ICCD and IsCMOS camera systems. The methodology allowed determination of superior SNR of the ICCD over the IsCMOS camera system and superior resolution of the IsCMOS over the ICCD camera system. Contrast depended upon the camera settings (binning and integration time) and gain of intensifier. Finally, because of architecture of CMOS and CCD camera systems resulting in vastly different performance, we comment on the utility of these systems for small animal imaging as well as clinical applications for non-invasive and surgical guidance. PMID:26552078
Volunteers Help Decide Where to Point Mars Camera
2015-07-22
This series of images from NASA's Mars Reconnaissance Orbiter successively zooms into "spider" features -- or channels carved in the surface in radial patterns -- in the south polar region of Mars. In a new citizen-science project, volunteers will identify features like these using wide-scale images from the orbiter. Their input will then help mission planners decide where to point the orbiter's high-resolution camera for more detailed views of interesting terrain. Volunteers will start with images from the orbiter's Context Camera (CTX), which provides wide views of the Red Planet. The first two images in this series are from CTX; the top right image zooms into a portion of the image at left. The top right image highlights the geological spider features, which are carved into the terrain in the Martian spring when dry ice turns to gas. By identifying unusual features like these, volunteers will help the mission team choose targets for the orbiter's High Resolution Imaging Science Experiment (HiRISE) camera, which can reveal more detail than any other camera ever put into orbit around Mars. The final image is this series (bottom right) shows a HiRISE close-up of one of the spider features. http://photojournal.jpl.nasa.gov/catalog/PIA19823
Poland, Michael P.; Dzurisin, Daniel; LaHusen, Richard G.; Major, John J.; Lapcewich, Dennis; Endo, Elliot T.; Gooding, Daniel J.; Schilling, Steve P.; Janda, Christine G.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.
2008-01-01
Images from a Web-based camera (Webcam) located 8 km north of Mount St. Helens and a network of remote, telemetered digital cameras were used to observe eruptive activity at the volcano between October 2004 and February 2006. The cameras offered the advantages of low cost, low power, flexibility in deployment, and high spatial and temporal resolution. Images obtained from the cameras provided important insights into several aspects of dome extrusion, including rockfalls, lava extrusion rates, and explosive activity. Images from the remote, telemetered digital cameras were assembled into time-lapse animations of dome extrusion that supported monitoring, research, and outreach efforts. The wide-ranging utility of remote camera imagery should motivate additional work, especially to develop the three-dimensional quantitative capabilities of terrestrial camera networks.
Video Capture of Plastic Surgery Procedures Using the GoPro HERO 3+.
Graves, Steven Nicholas; Shenaq, Deana Saleh; Langerman, Alexander J; Song, David H
2015-02-01
Significant improvements can be made in recoding surgical procedures, particularly in capturing high-quality video recordings from the surgeons' point of view. This study examined the utility of the GoPro HERO 3+ Black Edition camera for high-definition, point-of-view recordings of plastic and reconstructive surgery. The GoPro HERO 3+ Black Edition camera was head-mounted on the surgeon and oriented to the surgeon's perspective using the GoPro App. The camera was used to record 4 cases: 2 fat graft procedures and 2 breast reconstructions. During cases 1-3, an assistant remotely controlled the GoPro via the GoPro App. For case 4 the GoPro was linked to a WiFi remote, and controlled by the surgeon. Camera settings for case 1 were as follows: 1080p video resolution; 48 fps; Protune mode on; wide field of view; 16:9 aspect ratio. The lighting contrast due to the overhead lights resulted in limited washout of the video image. Camera settings were adjusted for cases 2-4 to a narrow field of view, which enabled the camera's automatic white balance to better compensate for bright lights focused on the surgical field. Cases 2-4 captured video sufficient for teaching or presentation purposes. The GoPro HERO 3+ Black Edition camera enables high-quality, cost-effective video recording of plastic and reconstructive surgery procedures. When set to a narrow field of view and automatic white balance, the camera is able to sufficiently compensate for the contrasting light environment of the operating room and capture high-resolution, detailed video.
NASA Astrophysics Data System (ADS)
Yamamoto, Seiichi; Suzuki, Mayumi; Kato, Katsuhiko; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Ogata, Yoshimune; Hatazawa, Jun
2016-09-01
Although iodine 131 (I-131) is used for radionuclide therapy, high resolution images are difficult to obtain with conventional gamma cameras because of the high energy of I-131 gamma photons (364 keV). Cerenkov-light imaging is a possible method for beta emitting radionuclides, and I-131 (606 MeV maximum beta energy) is a candidate to obtain high resolution images. We developed a high energy gamma camera system for I-131 radionuclide and combined it with a Cerenkov-light imaging system to form a gamma-photon/Cerenkov-light hybrid imaging system to compare the simultaneously measured images of these two modalities. The high energy gamma imaging detector used 0.85-mm×0.85-mm×10-mm thick GAGG scintillator pixels arranged in a 44×44 matrix with a 0.1-mm thick reflector and optical coupled to a Hamamatsu 2 in. square position sensitive photomultiplier tube (PSPMT: H12700 MOD). The gamma imaging detector was encased in a 2 cm thick tungsten shield, and a pinhole collimator was mounted on its top to form a gamma camera system. The Cerenkov-light imaging system was made of a high sensitivity cooled CCD camera. The Cerenkov-light imaging system was combined with the gamma camera using optical mirrors to image the same area of the subject. With this configuration, we simultaneously imaged the gamma photons and the Cerenkov-light from I-131 in the subjects. The spatial resolution and sensitivity of the gamma camera system for I-131 were respectively 3 mm FWHM and 10 cps/MBq for the high sensitivity collimator at 10 cm from the collimator surface. The spatial resolution of the Cerenkov-light imaging system was 0.64 mm FWHM at 10 cm from the system surface. Thyroid phantom and rat images were successfully obtained with the developed gamma-photon/Cerenkov-light hybrid imaging system, allowing direct comparison of these two modalities. Our developed gamma-photon/Cerenkov-light hybrid imaging system will be useful to evaluate the advantages and disadvantages of these two modalities.
Andreozzi, Jacqueline M; Zhang, Rongxiao; Glaser, Adam K; Jarvis, Lesley A; Pogue, Brian W; Gladstone, David J
2015-02-01
To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.
Surveying the Newly Digitized Apollo Metric Images for Highland Fault Scarps on the Moon
NASA Astrophysics Data System (ADS)
Williams, N. R.; Pritchard, M. E.; Bell, J. F.; Watters, T. R.; Robinson, M. S.; Lawrence, S.
2009-12-01
The presence and distribution of thrust faults on the Moon have major implications for lunar formation and thermal evolution. For example, thermal history models for the Moon imply that most of the lunar interior was initially hot. As the Moon cooled over time, some models predict global-scale thrust faults should form as stress builds from global thermal contraction. Large-scale thrust fault scarps with lengths of hundreds of kilometers and maximum relief of up to a kilometer or more, like those on Mercury, are not found on the Moon; however, relatively small-scale linear and curvilinear lobate scarps with maximum lengths typically around 10 km have been observed in the highlands [Binder and Gunga, Icarus, v63, 1985]. These small-scale scarps are interpreted to be thrust faults formed by contractional stresses with relatively small maximum (tens of meters) displacements on the faults. These narrow, low relief landforms could only be identified in the highest resolution Lunar Orbiter and Apollo Panoramic Camera images and under the most favorable lighting conditions. To date, the global distribution and other properties of lunar lobate faults are not well understood. The recent micron-resolution scanning and digitization of the Apollo Mapping Camera (Metric) photographic negatives [Lawrence et al., NLSI Conf. #1415, 2008; http://wms.lroc.asu.edu/apollo] provides a new dataset to search for potential scarps. We examined more than 100 digitized Metric Camera image scans, and from these identified 81 images with favorable lighting (incidence angles between about 55 and 80 deg.) to manually search for features that could be potential tectonic scarps. Previous surveys based on Panoramic Camera and Lunar Orbiter images found fewer than 100 lobate scarps in the highlands; in our Apollo Metric Camera image survey, we have found additional regions with one or more previously unidentified linear and curvilinear features on the lunar surface that may represent lobate thrust fault scarps. In this presentation we review the geologic characteristics and context of these newly-identified, potentially tectonic landforms. The lengths and relief of some of these linear and curvilinear features are consistent with previously identified lobate scarps. Most of these features are in the highlands, though a few occur along the edges of mare and/or crater ejecta deposits. In many cases the resolution of the Metric Camera frames (~10 m/pix) is not adequate to unequivocally determine the origin of these features. Thus, to assess if the newly identified features have tectonic or other origins, we are examining them in higher-resolution Panoramic Camera (currently being scanned) and Lunar Reconnaissance Orbiter Camera Narrow Angle Camera images [Watters et al., this meeting, 2009].
NASA Technical Reports Server (NTRS)
Clapp, Brian R.
2005-01-01
For fifteen years, the science mission of the Hubble Space Telescope (HST) required using at least three rate gyros for n Controlling with alternate sensors to replace failing gyros can extend the HST science mission. A two-gyro control law has been designed and implemented using magnetometers, star trackers, and Fine Guidance Sensors (FGSs) to control vehicle rate about the missing gyro axis. The three aforementioned sensors are used in succession to reduce HST boresight jitter to less than 7 milli-arcseconds rms prior to science imaging. The Magnetometer and 2-Gyro (M2G) control law is used for large angle maneuvers and attitude control during earth. occultation of star trackers and FGSs. The Tracker and 2-Gyro (T2G) control law dampens M2G rates and controls attitude in preparation for guide star acquisition with the FGSs. The Fine Guidance Sensor and 2-Gyro (F2G) control law dampens T2G rates and controls HST attitude during science imaging. This paper describes the F2G control law. Details of F2G algorithms are presented, including computation of the FGS-measured star vector using non-linear equations, optimal estimation of HST body rate, design of the F2G control laws and gyro bias observer, SISO and MIMO linear stability analyses, and design of the F2G intramode transition and guide star acquisition logic. Results from an FGS flight spare ground test are presented that define acceptable HST jitter levels for successful guide star acquisition under two-gyro control. HST-specific disturbance and noise models are described that are based upon flight telemetry; these models are used in HSTSIM, a high-fidelity non-linear time domain simulation, to predict HST on-orbit disturbance responses and FGS interferometer Loss of Lock (LOL) characteristics under F2G control. Additional HSTSIM results are presented predicting HST quiescent boresight jitter performance, science maneuver performance, and observer configuration performance during F2G operation. Simulation results are compared to on-orbit data b m F2G flight tests performed in February 2005. Science images and point spread functions from the Advanced Camera for Surveys (ACS) High Resolution Camera (HRC) are presented that compare HST science performance under F2G versus three-gyro control. Images and flight telemetry show that HST boresight jitter with the new F2G control law is usually less than jitter using the three-gyro law, and HST boresight jitter during F2G operation is dependent upon guide star magnitude.
NASA Technical Reports Server (NTRS)
Weigelt, G.; Albrecht, R.; Barbieri, C.; Blades, J. C.; Boksenberg, A.; Crane, P.; Deharveng, J. M.; Disney, M. J.; Jakobsen, P.; Kamperman, T. M.
1991-01-01
R136 is the luminous central object of the giant H II region 30 Doradus in the LMC. The first high-resolution observations of R136 with the Faint Object Camera on board the Hubble Space Telescope are reported. The physical nature of the brightest component R136a has been a matter of some controversy over the last few years. The UV images obtained show that R136a is a very compact star cluster consisting of more than eight stars within 0.7 arcsec diameter. From these high-resolution images a mass upper limit can be derived for the most luminous stars observed in R136.
UWB Tracking System Design for Free-Flyers
NASA Technical Reports Server (NTRS)
Ni, Jianjun; Arndt, Dickey; Phan, Chan; Ngo, Phong; Gross, Julia; Dusl, John
2004-01-01
This paper discusses an ultra-wideband (UWB) tracking system design effort for Mini-AERCam (Autonomous Extra-vehicular Robotic Camera), a free-flying video camera system under development at NASA Johnson Space Center for aid in surveillance around the International Space Station (ISS). UWB technology is exploited to implement the tracking system due to its properties, such as high data rate, fine time resolution, and low power spectral density. A system design using commercially available UWB products is proposed. A tracking algorithm TDOA (Time Difference of Arrival) that operates cooperatively with the UWB system is developed in this research effort. Matlab simulations show that the tracking algorithm can achieve fine tracking resolution with low noise TDOA data. Lab experiments demonstrate the UWB tracking capability with fine resolution.
Color image guided depth image super resolution using fusion filter
NASA Astrophysics Data System (ADS)
He, Jin; Liang, Bin; He, Ying; Yang, Jun
2018-04-01
Depth cameras are currently playing an important role in many areas. However, most of them can only obtain lowresolution (LR) depth images. Color cameras can easily provide high-resolution (HR) color images. Using color image as a guide image is an efficient way to get a HR depth image. In this paper, we propose a depth image super resolution (SR) algorithm, which uses a HR color image as a guide image and a LR depth image as input. We use the fusion filter of guided filter and edge based joint bilateral filter to get HR depth image. Our experimental results on Middlebury 2005 datasets show that our method can provide better quality in HR depth images both numerically and visually.
Hybrid Image Fusion for Sharpness Enhancement of Multi-Spectral Lunar Images
NASA Astrophysics Data System (ADS)
Awumah, Anna; Mahanti, Prasun; Robinson, Mark
2016-10-01
Image fusion enhances the sharpness of a multi-spectral (MS) image by incorporating spatial details from a higher-resolution panchromatic (Pan) image [1,2]. Known applications of image fusion for planetary images are rare, although image fusion is well-known for its applications to Earth-based remote sensing. In a recent work [3], six different image fusion algorithms were implemented and their performances were verified with images from the Lunar Reconnaissance Orbiter (LRO) Camera. The image fusion procedure obtained a high-resolution multi-spectral (HRMS) product from the LRO Narrow Angle Camera (used as Pan) and LRO Wide Angle Camera (used as MS) images. The results showed that the Intensity-Hue-Saturation (IHS) algorithm results in a high-spatial quality product while the Wavelet-based image fusion algorithm best preserves spectral quality among all the algorithms. In this work we show the results of a hybrid IHS-Wavelet image fusion algorithm when applied to LROC MS images. The hybrid method provides the best HRMS product - both in terms of spatial resolution and preservation of spectral details. Results from hybrid image fusion can enable new science and increase the science return from existing LROC images.[1] Pohl, Cle, and John L. Van Genderen. "Review article multisensor image fusion in remote sensing: concepts, methods and applications." International journal of remote sensing 19.5 (1998): 823-854.[2] Zhang, Yun. "Understanding image fusion." Photogramm. Eng. Remote Sens 70.6 (2004): 657-661.[3] Mahanti, Prasun et al. "Enhancement of spatial resolution of the LROC Wide Angle Camera images." Archives, XXIII ISPRS Congress Archives (2016).
ProxiScanâ¢: A Novel Camera for Imaging Prostate Cancer
Ralph James
2017-12-09
ProxiScan is a compact gamma camera suited for high-resolution imaging of prostate cancer. Developed by Brookhaven National Laboratory and Hybridyne Imaging Technologies, Inc., ProxiScan won a 2009 R&D 100 Award, sponsored by R&D Magazine to recognize t
Improved head-controlled TV system produces high-quality remote image
NASA Technical Reports Server (NTRS)
Goertz, R.; Lindberg, J.; Mingesz, D.; Potts, C.
1967-01-01
Manipulator operator uses an improved resolution tv camera/monitor positioning system to view the remote handling and processing of reactive, flammable, explosive, or contaminated materials. The pan and tilt motions of the camera and monitor are slaved to follow the corresponding motions of the operators head.
Vandenbroucke, A.; Innes, D.; Lau, F. W. Y.; Hsu, D. F. C.; Reynolds, P. D.; Levin, Craig S.
2015-01-01
Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm3 resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm3 LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image. PMID:25563270
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freese, D. L.; Vandenbroucke, A.; Innes, D.
2015-01-15
Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under constructionmore » consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.« less
Resolution recovery for Compton camera using origin ensemble algorithm.
Andreyev, A; Celler, A; Ozsahin, I; Sitek, A
2016-08-01
Compton cameras (CCs) use electronic collimation to reconstruct the images of activity distribution. Although this approach can greatly improve imaging efficiency, due to complex geometry of the CC principle, image reconstruction with the standard iterative algorithms, such as ordered subset expectation maximization (OSEM), can be very time-consuming, even more so if resolution recovery (RR) is implemented. We have previously shown that the origin ensemble (OE) algorithm can be used for the reconstruction of the CC data. Here we propose a method of extending our OE algorithm to include RR. To validate the proposed algorithm we used Monte Carlo simulations of a CC composed of multiple layers of pixelated CZT detectors and designed for imaging small animals. A series of CC acquisitions of small hot spheres and the Derenzo phantom placed in air were simulated. Images obtained from (a) the exact data, (b) blurred data but reconstructed without resolution recovery, and (c) blurred and reconstructed with resolution recovery were compared. Furthermore, the reconstructed contrast-to-background ratios were investigated using the phantom with nine spheres placed in a hot background. Our simulations demonstrate that the proposed method allows for the recovery of the resolution loss that is due to imperfect accuracy of event detection. Additionally, tests of camera sensitivity corresponding to different detector configurations demonstrate that the proposed CC design has sensitivity comparable to PET. When the same number of events were considered, the computation time per iteration increased only by a factor of 2 when OE reconstruction with the resolution recovery correction was performed relative to the original OE algorithm. We estimate that the addition of resolution recovery to the OSEM would increase reconstruction times by 2-3 orders of magnitude per iteration. The results of our tests demonstrate the improvement of image resolution provided by the OE reconstructions with resolution recovery. The quality of images and their contrast are similar to those obtained from the OE reconstructions from scans simulated with perfect energy and spatial resolutions.
High-Definition Television (HDTV) Images for Earth Observations and Earth Science Applications
NASA Technical Reports Server (NTRS)
Robinson, Julie A.; Holland, S. Douglas; Runco, Susan K.; Pitts, David E.; Whitehead, Victor S.; Andrefouet, Serge M.
2000-01-01
As part of Detailed Test Objective 700-17A, astronauts acquired Earth observation images from orbit using a high-definition television (HDTV) camcorder, Here we provide a summary of qualitative findings following completion of tests during missions STS (Space Transport System)-93 and STS-99. We compared HDTV imagery stills to images taken using payload bay video cameras, Hasselblad film camera, and electronic still camera. We also evaluated the potential for motion video observations of changes in sunlight and the use of multi-aspect viewing to image aerosols. Spatial resolution and color quality are far superior in HDTV images compared to National Television Systems Committee (NTSC) video images. Thus, HDTV provides the first viable option for video-based remote sensing observations of Earth from orbit. Although under ideal conditions, HDTV images have less spatial resolution than medium-format film cameras, such as the Hasselblad, under some conditions on orbit, the HDTV image acquired compared favorably with the Hasselblad. Of particular note was the quality of color reproduction in the HDTV images HDTV and electronic still camera (ESC) were not compared with matched fields of view, and so spatial resolution could not be compared for the two image types. However, the color reproduction of the HDTV stills was truer than colors in the ESC images. As HDTV becomes the operational video standard for Space Shuttle and Space Station, HDTV has great potential as a source of Earth-observation data. Planning for the conversion from NTSC to HDTV video standards should include planning for Earth data archiving and distribution.
Temporal Coding of Volumetric Imagery
NASA Astrophysics Data System (ADS)
Llull, Patrick Ryan
'Image volumes' refer to realizations of images in other dimensions such as time, spectrum, and focus. Recent advances in scientific, medical, and consumer applications demand improvements in image volume capture. Though image volume acquisition continues to advance, it maintains the same sampling mechanisms that have been used for decades; every voxel must be scanned and is presumed independent of its neighbors. Under these conditions, improving performance comes at the cost of increased system complexity, data rates, and power consumption. This dissertation explores systems and methods capable of efficiently improving sensitivity and performance for image volume cameras, and specifically proposes several sampling strategies that utilize temporal coding to improve imaging system performance and enhance our awareness for a variety of dynamic applications. Video cameras and camcorders sample the video volume (x,y,t) at fixed intervals to gain understanding of the volume's temporal evolution. Conventionally, one must reduce the spatial resolution to increase the framerate of such cameras. Using temporal coding via physical translation of an optical element known as a coded aperture, the compressive temporal imaging (CACTI) camera emonstrates a method which which to embed the temporal dimension of the video volume into spatial (x,y) measurements, thereby greatly improving temporal resolution with minimal loss of spatial resolution. This technique, which is among a family of compressive sampling strategies developed at Duke University, temporally codes the exposure readout functions at the pixel level. Since video cameras nominally integrate the remaining image volume dimensions (e.g. spectrum and focus) at capture time, spectral (x,y,t,lambda) and focal (x,y,t,z) image volumes are traditionally captured via sequential changes to the spectral and focal state of the system, respectively. The CACTI camera's ability to embed video volumes into images leads to exploration of other information within that video; namely, focal and spectral information. The next part of the thesis demonstrates derivative works of CACTI: compressive extended depth of field and compressive spectral-temporal imaging. These works successfully show the technique's extension of temporal coding to improve sensing performance in these other dimensions. Geometrical optics-related tradeoffs, such as the classic challenges of wide-field-of-view and high resolution photography, have motivated the development of mulitscale camera arrays. The advent of such designs less than a decade ago heralds a new era of research- and engineering-related challenges. One significant challenge is that of managing the focal volume (x,y,z ) over wide fields of view and resolutions. The fourth chapter shows advances on focus and image quality assessment for a class of multiscale gigapixel cameras developed at Duke. Along the same line of work, we have explored methods for dynamic and adaptive addressing of focus via point spread function engineering. We demonstrate another form of temporal coding in the form of physical translation of the image plane from its nominal focal position. We demonstrate this technique's capability to generate arbitrary point spread functions.
Changing the Department of Defense’s Policy on Homosexuals
2008-02-19
2007 from http://www.hrc.org/alva/dadt.html 18. Ottosson, D (2006, November), LGBT World Legal Wrap Up Survey, International Lesbian Gay...from http://www.gaywired.com/article.cfm?section=66&id=16683 Ottosson, D (2006, November), LGBT World Legal Wrap Up Survey, International
50 CFR 216.171 - Effective dates and definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 216.171 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS REGULATIONS GOVERNING THE TAKING AND IMPORTING OF MARINE MAMMALS Taking Marine Mammals Incidental to U.S. Navy Training in the Hawaii Range Complex (HRC) § 216.171...
Modeling and Simulation of High Resolution Optical Remote Sensing Satellite Geometric Chain
NASA Astrophysics Data System (ADS)
Xia, Z.; Cheng, S.; Huang, Q.; Tian, G.
2018-04-01
The high resolution satellite with the longer focal length and the larger aperture has been widely used in georeferencing of the observed scene in recent years. The consistent end to end model of high resolution remote sensing satellite geometric chain is presented, which consists of the scene, the three line array camera, the platform including attitude and position information, the time system and the processing algorithm. The integrated design of the camera and the star tracker is considered and the simulation method of the geolocation accuracy is put forward by introduce the new index of the angle between the camera and the star tracker. The model is validated by the geolocation accuracy simulation according to the test method of the ZY-3 satellite imagery rigorously. The simulation results show that the geolocation accuracy is within 25m, which is highly consistent with the test results. The geolocation accuracy can be improved about 7 m by the integrated design. The model combined with the simulation method is applicable to the geolocation accuracy estimate before the satellite launching.
New technology and techniques for x-ray mirror calibration at PANTER
NASA Astrophysics Data System (ADS)
Freyberg, Michael J.; Budau, Bernd; Burkert, Wolfgang; Friedrich, Peter; Hartner, Gisela; Misaki, Kazutami; Mühlegger, Martin
2008-07-01
The PANTER X-ray Test Facility has been utilized successfully for developing and calibrating X-ray astronomical instrumentation for observatories such as ROSAT, Chandra, XMM-Newton, Swift, etc. Future missions like eROSITA, SIMBOL-X, or XEUS require improved spatial resolution and broader energy band pass, both for optics and for cameras. Calibration campaigns at PANTER have made use of flight spare instrumentation for space applications; here we report on a new dedicated CCD camera for on-ground calibration, called TRoPIC. As the CCD is similar to ones used for eROSITA (pn-type, back-illuminated, 75 μm pixel size, frame store mode, 450 μm micron wafer thickness, etc.) it can serve as prototype for eROSITA camera development. New techniques enable and enhance the analysis of measurements of eROSITA shells or silicon pore optics. Specifically, we show how sub-pixel resolution can be utilized to improve spatial resolution and subsequently the characterization of of mirror shell quality and of point spread function parameters in particular, also relevant for position reconstruction of astronomical sources in orbit.
Performance Characteristics For The Orbiter Camera Payload System's Large Format Camera (LFC)
NASA Astrophysics Data System (ADS)
MoIIberg, Bernard H.
1981-11-01
The Orbiter Camera Payload System, the OCPS, is an integrated photographic system which is carried into Earth orbit as a payload in the Shuttle Orbiter vehicle's cargo bay. The major component of the OCPS is a Large Format Camera (LFC) which is a precision wide-angle cartographic instrument that is capable of produc-ing high resolution stereophotography of great geometric fidelity in multiple base to height ratios. The primary design objective for the LFC was to maximize all system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment.
Compact CdZnTe-based gamma camera for prostate cancer imaging
NASA Astrophysics Data System (ADS)
Cui, Yonggang; Lall, Terry; Tsui, Benjamin; Yu, Jianhua; Mahler, George; Bolotnikov, Aleksey; Vaska, Paul; De Geronimo, Gianluigi; O'Connor, Paul; Meinken, George; Joyal, John; Barrett, John; Camarda, Giuseppe; Hossain, Anwar; Kim, Ki Hyun; Yang, Ge; Pomper, Marty; Cho, Steve; Weisman, Ken; Seo, Youngho; Babich, John; LaFrance, Norman; James, Ralph B.
2011-06-01
In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high falsepositive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integratedcircuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.
Nanometric depth resolution from multi-focal images in microscopy.
Dalgarno, Heather I C; Dalgarno, Paul A; Dada, Adetunmise C; Towers, Catherine E; Gibson, Gavin J; Parton, Richard M; Davis, Ilan; Warburton, Richard J; Greenaway, Alan H
2011-07-06
We describe a method for tracking the position of small features in three dimensions from images recorded on a standard microscope with an inexpensive attachment between the microscope and the camera. The depth-measurement accuracy of this method is tested experimentally on a wide-field, inverted microscope and is shown to give approximately 8 nm depth resolution, over a specimen depth of approximately 6 µm, when using a 12-bit charge-coupled device (CCD) camera and very bright but unresolved particles. To assess low-flux limitations a theoretical model is used to derive an analytical expression for the minimum variance bound. The approximations used in the analytical treatment are tested using numerical simulations. It is concluded that approximately 14 nm depth resolution is achievable with flux levels available when tracking fluorescent sources in three dimensions in live-cell biology and that the method is suitable for three-dimensional photo-activated localization microscopy resolution. Sub-nanometre resolution could be achieved with photon-counting techniques at high flux levels.
Nanometric depth resolution from multi-focal images in microscopy
Dalgarno, Heather I. C.; Dalgarno, Paul A.; Dada, Adetunmise C.; Towers, Catherine E.; Gibson, Gavin J.; Parton, Richard M.; Davis, Ilan; Warburton, Richard J.; Greenaway, Alan H.
2011-01-01
We describe a method for tracking the position of small features in three dimensions from images recorded on a standard microscope with an inexpensive attachment between the microscope and the camera. The depth-measurement accuracy of this method is tested experimentally on a wide-field, inverted microscope and is shown to give approximately 8 nm depth resolution, over a specimen depth of approximately 6 µm, when using a 12-bit charge-coupled device (CCD) camera and very bright but unresolved particles. To assess low-flux limitations a theoretical model is used to derive an analytical expression for the minimum variance bound. The approximations used in the analytical treatment are tested using numerical simulations. It is concluded that approximately 14 nm depth resolution is achievable with flux levels available when tracking fluorescent sources in three dimensions in live-cell biology and that the method is suitable for three-dimensional photo-activated localization microscopy resolution. Sub-nanometre resolution could be achieved with photon-counting techniques at high flux levels. PMID:21247948
Characterization of the LBNL PEM Camera
NASA Astrophysics Data System (ADS)
Wang, G.-C.; Huber, J. S.; Moses, W. W.; Qi, J.; Choong, W.-S.
2006-06-01
We present the tomographic images and performance measurements of the LBNL positron emission mammography (PEM) camera, a specially designed positron emission tomography (PET) camera that utilizes PET detector modules with depth of interaction measurement capability to achieve both high sensitivity and high resolution for breast cancer detection. The camera currently consists of 24 detector modules positioned as four detector banks to cover a rectangular patient port that is 8.2/spl times/6 cm/sup 2/ with a 5 cm axial extent. Each LBNL PEM detector module consists of 64 3/spl times/3/spl times/30 mm/sup 3/ LSO crystals coupled to a single photomultiplier tube (PMT) and an 8/spl times/8 silicon photodiode array (PD). The PMT provides accurate timing, the PD identifies the crystal of interaction, the sum of the PD and PMT signals (PD+PMT) provides the total energy, and the PD/(PD+PMT) ratio determines the depth of interaction. The performance of the camera has been evaluated by imaging various phantoms. The full-width-at-half-maximum (FWHM) spatial resolution changes slightly from 1.9 mm to 2.1 mm when measured at the center and corner of the field of the view, respectively, using a 6 ns coincidence timing window and a 300-750 keV energy window. With the same setup, the peak sensitivity of the camera is 1.83 kcps//spl mu/Ci.
Optical design of space cameras for automated rendezvous and docking systems
NASA Astrophysics Data System (ADS)
Zhu, X.
2018-05-01
Visible cameras are essential components of a space automated rendezvous and docking (AR and D) system, which is utilized in many space missions including crewed or robotic spaceship docking, on-orbit satellite servicing, autonomous landing and hazard avoidance. Cameras are ubiquitous devices in modern time with countless lens designs that focus on high resolution and color rendition. In comparison, space AR and D cameras, while are not required to have extreme high resolution and color rendition, impose some unique requirements on lenses. Fixed lenses with no moving parts and separated lenses for narrow and wide field-of-view (FOV) are normally used in order to meet high reliability requirement. Cemented lens elements are usually avoided due to wide temperature swing and outgassing requirement in space environment. The lenses should be designed with exceptional straylight performance and minimum lens flare given intense sun light and lacking of atmosphere scattering in space. Furthermore radiation resistant glasses should be considered to prevent glass darkening from space radiation. Neptec has designed and built a narrow FOV (NFOV) lens and a wide FOV (WFOV) lens for an AR and D visible camera system. The lenses are designed by using ZEMAX program; the straylight performance and the lens baffles are simulated by using TracePro program. This paper discusses general requirements for space AR and D camera lenses and the specific measures for lenses to meet the space environmental requirements.
UWB Tracking System Design with TDOA Algorithm
NASA Technical Reports Server (NTRS)
Ni, Jianjun; Arndt, Dickey; Ngo, Phong; Phan, Chau; Gross, Julia; Dusl, John; Schwing, Alan
2006-01-01
This presentation discusses an ultra-wideband (UWB) tracking system design effort using a tracking algorithm TDOA (Time Difference of Arrival). UWB technology is exploited to implement the tracking system due to its properties, such as high data rate, fine time resolution, and low power spectral density. A system design using commercially available UWB products is proposed. A two-stage weighted least square method is chosen to solve the TDOA non-linear equations. Matlab simulations in both two-dimensional space and three-dimensional space show that the tracking algorithm can achieve fine tracking resolution with low noise TDOA data. The error analysis reveals various ways to improve the tracking resolution. Lab experiments demonstrate the UWBTDOA tracking capability with fine resolution. This research effort is motivated by a prototype development project Mini-AERCam (Autonomous Extra-vehicular Robotic Camera), a free-flying video camera system under development at NASA Johnson Space Center for aid in surveillance around the International Space Station (ISS).
High-resolution Ceres Low Altitude Mapping Orbit Atlas derived from Dawn Framing Camera images
NASA Astrophysics Data System (ADS)
Roatsch, Th.; Kersten, E.; Matz, K.-D.; Preusker, F.; Scholten, F.; Jaumann, R.; Raymond, C. A.; Russell, C. T.
2017-06-01
The Dawn spacecraft Framing Camera (FC) acquired over 31,300 clear filter images of Ceres with a resolution of about 35 m/pxl during the eleven cycles in the Low Altitude Mapping Orbit (LAMO) phase between December 16 2015 and August 8 2016. We ortho-rectified the images from the first four cycles and produced a global, high-resolution, uncontrolled photomosaic of Ceres. This global mosaic is the basis for a high-resolution Ceres atlas that consists of 62 tiles mapped at a scale of 1:250,000. The nomenclature used in this atlas was proposed by the Dawn team and was approved by the International Astronomical Union (IAU). The full atlas is available to the public through the Dawn Geographical Information System (GIS) web page [http://dawngis.dlr.de/atlas] and will become available through the NASA Planetary Data System (PDS) (http://pdssbn.astro.umd.edu/).
LWIR NUC using an uncooled microbolometer camera
NASA Astrophysics Data System (ADS)
Laveigne, Joe; Franks, Greg; Sparkman, Kevin; Prewarski, Marcus; Nehring, Brian; McHugh, Steve
2010-04-01
Performing a good non-uniformity correction is a key part of achieving optimal performance from an infrared scene projector. Ideally, NUC will be performed in the same band in which the scene projector will be used. Cooled, large format MWIR cameras are readily available and have been successfully used to perform NUC, however, cooled large format LWIR cameras are not as common and are prohibitively expensive. Large format uncooled cameras are far more available and affordable, but present a range of challenges in practical use for performing NUC on an IRSP. Santa Barbara Infrared, Inc. reports progress on a continuing development program to use a microbolometer camera to perform LWIR NUC on an IRSP. Camera instability and temporal response and thermal resolution are the main difficulties. A discussion of processes developed to mitigate these issues follows.
Efficient space-time sampling with pixel-wise coded exposure for high-speed imaging.
Liu, Dengyu; Gu, Jinwei; Hitomi, Yasunobu; Gupta, Mohit; Mitsunaga, Tomoo; Nayar, Shree K
2014-02-01
Cameras face a fundamental trade-off between spatial and temporal resolution. Digital still cameras can capture images with high spatial resolution, but most high-speed video cameras have relatively low spatial resolution. It is hard to overcome this trade-off without incurring a significant increase in hardware costs. In this paper, we propose techniques for sampling, representing, and reconstructing the space-time volume to overcome this trade-off. Our approach has two important distinctions compared to previous works: 1) We achieve sparse representation of videos by learning an overcomplete dictionary on video patches, and 2) we adhere to practical hardware constraints on sampling schemes imposed by architectures of current image sensors, which means that our sampling function can be implemented on CMOS image sensors with modified control units in the future. We evaluate components of our approach, sampling function and sparse representation, by comparing them to several existing approaches. We also implement a prototype imaging system with pixel-wise coded exposure control using a liquid crystal on silicon device. System characteristics such as field of view and modulation transfer function are evaluated for our imaging system. Both simulations and experiments on a wide range of scenes show that our method can effectively reconstruct a video from a single coded image while maintaining high spatial resolution.
The High Resolution Stereo Camera (HRSC): 10 Years of Imaging Mars
NASA Astrophysics Data System (ADS)
Jaumann, R.; Neukum, G.; Tirsch, D.; Hoffmann, H.
2014-04-01
The HRSC Experiment: Imagery is the major source for our current understanding of the geologic evolution of Mars in qualitative and quantitative terms.Imaging is required to enhance our knowledge of Mars with respect to geological processes occurring on local, regional and global scales and is an essential prerequisite for detailed surface exploration. The High Resolution Stereo Camera (HRSC) of ESA's Mars Express Mission (MEx) is designed to simultaneously map the morphology, topography, structure and geologic context of the surface of Mars as well as atmospheric phenomena [1]. The HRSC directly addresses two of the main scientific goals of the Mars Express mission: (1) High-resolution three-dimensional photogeologic surface exploration and (2) the investigation of surface-atmosphere interactions over time; and significantly supports: (3) the study of atmospheric phenomena by multi-angle coverage and limb sounding as well as (4) multispectral mapping by providing high-resolution threedimensional color context information. In addition, the stereoscopic imagery will especially characterize landing sites and their geologic context [1]. The HRSC surface resolution and the digital terrain models bridge the gap in scales between highest ground resolution images (e.g., HiRISE) and global coverage observations (e.g., Viking). This is also the case with respect to DTMs (e.g., MOLA and local high-resolution DTMs). HRSC is also used as cartographic basis to correlate between panchromatic and multispectral stereo data. The unique multi-angle imaging technique of the HRSC supports its stereo capability by providing not only a stereo triplet but also a stereo quintuplet, making the photogrammetric processing very robust [1, 3]. The capabilities for three dimensional orbital reconnaissance of the Martian surface are ideally met by HRSC making this camera unique in the international Mars exploration effort.
A design of camera simulator for photoelectric image acquisition system
NASA Astrophysics Data System (ADS)
Cai, Guanghui; Liu, Wen; Zhang, Xin
2015-02-01
In the process of developing the photoelectric image acquisition equipment, it needs to verify the function and performance. In order to make the photoelectric device recall the image data formerly in the process of debugging and testing, a design scheme of the camera simulator is presented. In this system, with FPGA as the control core, the image data is saved in NAND flash trough USB2.0 bus. Due to the access rate of the NAND, flash is too slow to meet the requirement of the sytsem, to fix the problem, the pipeline technique and the High-Band-Buses technique are applied in the design to improve the storage rate. It reads image data out from flash in the control logic of FPGA and output separately from three different interface of Camera Link, LVDS and PAL, which can provide image data for photoelectric image acquisition equipment's debugging and algorithm validation. However, because the standard of PAL image resolution is 720*576, the resolution is different between PAL image and input image, so the image can be output after the resolution conversion. The experimental results demonstrate that the camera simulator outputs three format image sequence correctly, which can be captured and displayed by frame gather. And the three-format image data can meet test requirements of the most equipment, shorten debugging time and improve the test efficiency.
A new spherical scanning system for infrared reflectography of paintings
NASA Astrophysics Data System (ADS)
Gargano, M.; Cavaliere, F.; Viganò, D.; Galli, A.; Ludwig, N.
2017-03-01
Infrared reflectography is an imaging technique used to visualize the underdrawings of ancient paintings; it relies on the fact that most pigment layers are quite transparent to infrared radiation in the spectral band between 0.8 μm and 2.5 μm. InGaAs sensor cameras are nowadays the most used devices to visualize the underdrawings but due to the small size of the detectors, these cameras are usually mounted on scanning systems to record high resolution reflectograms. This work describes a portable scanning system prototype based on a peculiar spherical scanning system built through a light weight and low cost motorized head. The motorized head was built with the purpose of allowing the refocusing adjustment needed to compensate the variable camera-painting distance during the rotation of the camera. The prototype has been tested first in laboratory and then in-situ for the Giotto panel "God the Father with Angels" with a 256 pixel per inch resolution. The system performance is comparable with that of other reflectographic devices with the advantage of extending the scanned area up to 1 m × 1 m, with a 40 min scanning time. The present configuration can be easily modified to increase the resolution up to 560 pixels per inch or to extend the scanned area up to 2 m × 2 m.
Low-cost, high-resolution scanning laser ophthalmoscope for the clinical environment
NASA Astrophysics Data System (ADS)
Soliz, P.; Larichev, A.; Zamora, G.; Murillo, S.; Barriga, E. S.
2010-02-01
Researchers have sought to gain greater insight into the mechanisms of the retina and the optic disc at high spatial resolutions that would enable the visualization of small structures such as photoreceptors and nerve fiber bundles. The sources of retinal image quality degradation are aberrations within the human eye, which limit the achievable resolution and the contrast of small image details. To overcome these fundamental limitations, researchers have been applying adaptive optics (AO) techniques to correct for the aberrations. Today, deformable mirror based adaptive optics devices have been developed to overcome the limitations of standard fundus cameras, but at prices that are typically unaffordable for most clinics. In this paper we demonstrate a clinically viable fundus camera with auto-focus and astigmatism correction that is easy to use and has improved resolution. We have shown that removal of low-order aberrations results in significantly better resolution and quality images. Additionally, through the application of image restoration and super-resolution techniques, the images present considerably improved quality. The improvements lead to enhanced visualization of retinal structures associated with pathology.
,
2008-01-01
Interested in a photograph of the first space walk by an American astronaut, or the first photograph from space of a solar eclipse? Or maybe your interest is in a specific geologic, oceanic, or meteorological phenomenon? The U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center is making photographs of the Earth taken from space available for search, download, and ordering. These photographs were taken by Gemini mission astronauts with handheld cameras or by the Large Format Camera that flew on space shuttle Challenger in October 1984. Space photographs are distributed by EROS only as high-resolution scanned or medium-resolution digital products.
Dynamic frequency-domain interferometer for absolute distance measurements with high resolution
NASA Astrophysics Data System (ADS)
Weng, Jidong; Liu, Shenggang; Ma, Heli; Tao, Tianjiong; Wang, Xiang; Liu, Cangli; Tan, Hua
2014-11-01
A unique dynamic frequency-domain interferometer for absolute distance measurement has been developed recently. This paper presents the working principle of the new interferometric system, which uses a photonic crystal fiber to transmit the wide-spectrum light beams and a high-speed streak camera or frame camera to record the interference stripes. Preliminary measurements of harmonic vibrations of a speaker, driven by a radio, and the changes in the tip clearance of a rotating gear wheel show that this new type of interferometer has the ability to perform absolute distance measurements both with high time- and distance-resolution.
Image quality prediction: an aid to the Viking Lander imaging investigation on Mars.
Huck, F O; Wall, S D
1976-07-01
Two Viking spacecraft scheduled to land on Mars in the summer of 1976 will return multispectral panoramas of the Martian surface with resolutions 4 orders of magnitude higher than have been previously obtained and stereo views with resolutions approaching that of the human eye. Mission constraints and uncertainties require a carefully planned imaging investigation that is supported by a computer model of camera response and surface features to aid in diagnosing camera performance, in establishing a preflight imaging strategy, and in rapidly revising this strategy if pictures returned from Mars reveal unfavorable or unanticipated conditions.
Lee, Chang Kyu; Kim, Youngjun; Lee, Nam; Kim, Byeongwoo; Kim, Doyoung; Yi, Seong
2017-02-15
Study for feasibility of commercially available action cameras in recording video of spine. Recent innovation of the wearable action camera with high-definition video recording enables surgeons to use camera in the operation at ease without high costs. The purpose of this study is to compare the feasibility, safety, and efficacy of commercially available action cameras in recording video of spine surgery. There are early reports of medical professionals using Google Glass throughout the hospital, Panasonic HX-A100 action camera, and GoPro. This study is the first report for spine surgery. Three commercially available cameras were tested: GoPro Hero 4 Silver, Google Glass, and Panasonic HX-A100 action camera. Typical spine surgery was selected for video recording; posterior lumbar laminectomy and fusion. Three cameras were used by one surgeon and video was recorded throughout the operation. The comparison was made on the perspective of human factor, specification, and video quality. The most convenient and lightweight device for wearing and holding throughout the long operation time was Google Glass. The image quality; all devices except Google Glass supported HD format and GoPro has unique 2.7K or 4K resolution. Quality of video resolution was best in GoPro. Field of view, GoPro can adjust point of interest, field of view according to the surgery. Narrow FOV option was the best for recording in GoPro to share the video clip. Google Glass has potentials by using application programs. Connectivity such as Wi-Fi and Bluetooth enables video streaming for audience, but only Google Glass has two-way communication feature in device. Action cameras have the potential to improve patient safety, operator comfort, and procedure efficiency in the field of spinal surgery and broadcasting a surgery with development of the device and applied program in the future. N/A.
Characterization of SWIR cameras by MRC measurements
NASA Astrophysics Data System (ADS)
Gerken, M.; Schlemmer, H.; Haan, Hubertus A.; Siemens, Christofer; Münzberg, M.
2014-05-01
Cameras for the SWIR wavelength range are becoming more and more important because of the better observation range for day-light operation under adverse weather conditions (haze, fog, rain). In order to choose the best suitable SWIR camera or to qualify a camera for a given application, characterization of the camera by means of the Minimum Resolvable Contrast MRC concept is favorable as the MRC comprises all relevant properties of the instrument. With the MRC known for a given camera device the achievable observation range can be calculated for every combination of target size, illumination level or weather conditions. MRC measurements in the SWIR wavelength band can be performed widely along the guidelines of the MRC measurements of a visual camera. Typically measurements are performed with a set of resolution targets (e.g. USAF 1951 target) manufactured with different contrast values from 50% down to less than 1%. For a given illumination level the achievable spatial resolution is then measured for each target. The resulting curve is showing the minimum contrast that is necessary to resolve the structure of a target as a function of spatial frequency. To perform MRC measurements for SWIR cameras at first the irradiation parameters have to be given in radiometric instead of photometric units which are limited in their use to the visible range. In order to do so, SWIR illumination levels for typical daylight and twilight conditions have to be defined. At second, a radiation source is necessary with appropriate emission in the SWIR range (e.g. incandescent lamp) and the irradiance has to be measured in W/m2 instead of Lux = Lumen/m2. At third, the contrast values of the targets have to be calibrated newly for the SWIR range because they typically differ from the values determined for the visual range. Measured MRC values of three cameras are compared to the specified performance data of the devices and the results of a multi-band in-house designed Vis-SWIR camera system are discussed.
HRSC: High resolution stereo camera
Neukum, G.; Jaumann, R.; Basilevsky, A.T.; Dumke, A.; Van Gasselt, S.; Giese, B.; Hauber, E.; Head, J. W.; Heipke, C.; Hoekzema, N.; Hoffmann, H.; Greeley, R.; Gwinner, K.; Kirk, R.; Markiewicz, W.; McCord, T.B.; Michael, G.; Muller, Jan-Peter; Murray, J.B.; Oberst, J.; Pinet, P.; Pischel, R.; Roatsch, T.; Scholten, F.; Willner, K.
2009-01-01
The High Resolution Stereo Camera (HRSC) on Mars Express has delivered a wealth of image data, amounting to over 2.5 TB from the start of the mapping phase in January 2004 to September 2008. In that time, more than a third of Mars was covered at a resolution of 10-20 m/pixel in stereo and colour. After five years in orbit, HRSC is still in excellent shape, and it could continue to operate for many more years. HRSC has proven its ability to close the gap between the low-resolution Viking image data and the high-resolution Mars Orbiter Camera images, leading to a global picture of the geological evolution of Mars that is now much clearer than ever before. Derived highest-resolution terrain model data have closed major gaps and provided an unprecedented insight into the shape of the surface, which is paramount not only for surface analysis and geological interpretation, but also for combination with and analysis of data from other instruments, as well as in planning for future missions. This chapter presents the scientific output from data analysis and highlevel data processing, complemented by a summary of how the experiment is conducted by the HRSC team members working in geoscience, atmospheric science, photogrammetry and spectrophotometry. Many of these contributions have been or will be published in peer-reviewed journals and special issues. They form a cross-section of the scientific output, either by summarising the new geoscientific picture of Mars provided by HRSC or by detailing some of the topics of data analysis concerning photogrammetry, cartography and spectral data analysis.
NASA Astrophysics Data System (ADS)
Javh, Jaka; Slavič, Janko; Boltežar, Miha
2018-02-01
Instantaneous full-field displacement fields can be measured using cameras. In fact, using high-speed cameras full-field spectral information up to a couple of kHz can be measured. The trouble is that high-speed cameras capable of measuring high-resolution fields-of-view at high frame rates prove to be very expensive (from tens to hundreds of thousands of euro per camera). This paper introduces a measurement set-up capable of measuring high-frequency vibrations using slow cameras such as DSLR, mirrorless and others. The high-frequency displacements are measured by harmonically blinking the lights at specified frequencies. This harmonic blinking of the lights modulates the intensity changes of the filmed scene and the camera-image acquisition makes the integration over time, thereby producing full-field Fourier coefficients of the filmed structure's displacements.
50 CFR 216.178 - Renewal of Letters of Authorization.
Code of Federal Regulations, 2011 CFR
2011-10-01
... IMPORTING OF MARINE MAMMALS Taking Marine Mammals Incidental to U.S. Navy Training in the Hawaii Range... previous year (either from the HRC or other locations). (2) Findings of the Monitoring Workshop that the... explosives training or not involving coincident use). (5) Results from the Long Term Prospective Study. (6...
50 CFR 216.178 - Renewal of Letters of Authorization.
Code of Federal Regulations, 2010 CFR
2010-10-01
... IMPORTING OF MARINE MAMMALS Taking Marine Mammals Incidental to U.S. Navy Training in the Hawaii Range... previous year (either from the HRC or other locations). (2) Findings of the Monitoring Workshop that the... explosives training or not involving coincident use). (5) Results from the Long Term Prospective Study. (6...
Single-pixel camera with one graphene photodetector.
Li, Gongxin; Wang, Wenxue; Wang, Yuechao; Yang, Wenguang; Liu, Lianqing
2016-01-11
Consumer cameras in the megapixel range are ubiquitous, but the improvement of them is hindered by the poor performance and high cost of traditional photodetectors. Graphene, a two-dimensional micro-/nano-material, recently has exhibited exceptional properties as a sensing element in a photodetector over traditional materials. However, it is difficult to fabricate a large-scale array of graphene photodetectors to replace the traditional photodetector array. To take full advantage of the unique characteristics of the graphene photodetector, in this study we integrated a graphene photodetector in a single-pixel camera based on compressive sensing. To begin with, we introduced a method called laser scribing for fabrication the graphene. It produces the graphene components in arbitrary patterns more quickly without photoresist contamination as do traditional methods. Next, we proposed a system for calibrating the optoelectrical properties of micro/nano photodetectors based on a digital micromirror device (DMD), which changes the light intensity by controlling the number of individual micromirrors positioned at + 12°. The calibration sensitivity is driven by the sum of all micromirrors of the DMD and can be as high as 10(-5)A/W. Finally, the single-pixel camera integrated with one graphene photodetector was used to recover a static image to demonstrate the feasibility of the single-pixel imaging system with the graphene photodetector. A high-resolution image can be recovered with the camera at a sampling rate much less than Nyquist rate. The study was the first demonstration for ever record of a macroscopic camera with a graphene photodetector. The camera has the potential for high-speed and high-resolution imaging at much less cost than traditional megapixel cameras.
New opportunities for quality enhancing of images captured by passive THz camera
NASA Astrophysics Data System (ADS)
Trofimov, Vyacheslav A.; Trofimov, Vladislav V.
2014-10-01
As it is well-known, the passive THz camera allows seeing concealed object without contact with a person and this camera is non-dangerous for a person. Obviously, efficiency of using the passive THz camera depends on its temperature resolution. This characteristic specifies possibilities of the detection for concealed object: minimal size of the object; maximal distance of the detection; image quality. Computer processing of the THz image may lead to many times improving of the image quality without any additional engineering efforts. Therefore, developing of modern computer code for its application to THz images is urgent problem. Using appropriate new methods one may expect such temperature resolution which will allow to see banknote in pocket of a person without any real contact. Modern algorithms for computer processing of THz images allow also to see object inside the human body using a temperature trace on the human skin. This circumstance enhances essentially opportunity of passive THz camera applications for counterterrorism problems. We demonstrate opportunities, achieved at present time, for the detection both of concealed objects and of clothes components due to using of computer processing of images captured by passive THz cameras, manufactured by various companies. Another important result discussed in the paper consists in observation of both THz radiation emitted by incandescent lamp and image reflected from ceramic floorplate. We consider images produced by THz passive cameras manufactured by Microsemi Corp., and ThruVision Corp., and Capital Normal University (Beijing, China). All algorithms for computer processing of the THz images under consideration in this paper were developed by Russian part of author list. Keywords: THz wave, passive imaging camera, computer processing, security screening, concealed and forbidden objects, reflected image, hand seeing, banknote seeing, ceramic floorplate, incandescent lamp.
Development of infrared scene projectors for testing fire-fighter cameras
NASA Astrophysics Data System (ADS)
Neira, Jorge E.; Rice, Joseph P.; Amon, Francine K.
2008-04-01
We have developed two types of infrared scene projectors for hardware-in-the-loop testing of thermal imaging cameras such as those used by fire-fighters. In one, direct projection, images are projected directly into the camera. In the other, indirect projection, images are projected onto a diffuse screen, which is then viewed by the camera. Both projectors use a digital micromirror array as the spatial light modulator, in the form of a Micromirror Array Projection System (MAPS) engine having resolution of 800 x 600 with mirrors on a 17 micrometer pitch, aluminum-coated mirrors, and a ZnSe protective window. Fire-fighter cameras are often based upon uncooled microbolometer arrays and typically have resolutions of 320 x 240 or lower. For direct projection, we use an argon-arc source, which provides spectral radiance equivalent to a 10,000 Kelvin blackbody over the 7 micrometer to 14 micrometer wavelength range, to illuminate the micromirror array. For indirect projection, an expanded 4 watt CO II laser beam at a wavelength of 10.6 micrometers illuminates the micromirror array and the scene formed by the first-order diffracted light from the array is projected onto a diffuse aluminum screen. In both projectors, a well-calibrated reference camera is used to provide non-uniformity correction and brightness calibration of the projected scenes, and the fire-fighter cameras alternately view the same scenes. In this paper, we compare the two methods for this application and report on our quantitative results. Indirect projection has an advantage of being able to more easily fill the wide field of view of the fire-fighter cameras, which typically is about 50 degrees. Direct projection more efficiently utilizes the available light, which will become important in emerging multispectral and hyperspectral applications.
Tracking a Head-Mounted Display in a Room-Sized Environment with Head-Mounted Cameras
1990-04-01
poor resolution and a very limited working volume [Wan90]. 4 OPTOTRAK [Nor88] uses one camera with two dual-axis CCD infrared position sensors. Each...Nor88] Northern Digital. Trade literature on Optotrak - Northern Digital’s Three Dimensional Optical Motion Tracking and Analysis System. Northern Digital
Processing Ocean Images to Detect Large Drift Nets
NASA Technical Reports Server (NTRS)
Veenstra, Tim
2009-01-01
A computer program processes the digitized outputs of a set of downward-looking video cameras aboard an aircraft flying over the ocean. The purpose served by this software is to facilitate the detection of large drift nets that have been lost, abandoned, or jettisoned. The development of this software and of the associated imaging hardware is part of a larger effort to develop means of detecting and removing large drift nets before they cause further environmental damage to the ocean and to shores on which they sometimes impinge. The software is capable of near-realtime processing of as many as three video feeds at a rate of 30 frames per second. After a user sets the parameters of an adjustable algorithm, the software analyzes each video stream, detects any anomaly, issues a command to point a high-resolution camera toward the location of the anomaly, and, once the camera has been so aimed, issues a command to trigger the camera shutter. The resulting high-resolution image is digitized, and the resulting data are automatically uploaded to the operator s computer for analysis.
Geomorphologic mapping of the lunar crater Tycho and its impact melt deposits
NASA Astrophysics Data System (ADS)
Krüger, T.; van der Bogert, C. H.; Hiesinger, H.
2016-07-01
Using SELENE/Kaguya Terrain Camera and Lunar Reconnaissance Orbiter Camera (LROC) data, we produced a new, high-resolution (10 m/pixel), geomorphological and impact melt distribution map for the lunar crater Tycho. The distal ejecta blanket and crater rays were investigated using LROC wide-angle camera (WAC) data (100 m/pixel), while the fine-scale morphologies of individual units were documented using high resolution (∼0.5 m/pixel) LROC narrow-angle camera (NAC) frames. In particular, Tycho shows a large coherent melt sheet on the crater floor, melt pools and flows along the terraced walls, and melt pools on the continuous ejecta blanket. The crater floor of Tycho exhibits three distinct units, distinguishable by their elevation and hummocky surface morphology. The distribution of impact melt pools and ejecta, as well as topographic asymmetries, support the formation of Tycho as an oblique impact from the W-SW. The asymmetric ejecta blanket, significantly reduced melt emplacement uprange, and the depressed uprange crater rim at Tycho suggest an impact angle of ∼25-45°.
Gustafson, J. Olaf; Bell, James F.; Gaddis, Lisa R.R.; Hawke, B. Ray Ray; Giguere, Thomas A.
2012-01-01
We used a Lunar Reconnaissance Orbiter Camera (LROC) global monochrome Wide-angle Camera (WAC) mosaic to conduct a survey of the Moon to search for previously unidentified pyroclastic deposits. Promising locations were examined in detail using LROC multispectral WAC mosaics, high-resolution LROC Narrow Angle Camera (NAC) images, and Clementine multispectral (ultraviolet-visible or UVVIS) data. Out of 47 potential deposits chosen for closer examination, 12 were selected as probable newly identified pyroclastic deposits. Potential pyroclastic deposits were generally found in settings similar to previously identified deposits, including areas within or near mare deposits adjacent to highlands, within floor-fractured craters, and along fissures in mare deposits. However, a significant new finding is the discovery of localized pyroclastic deposits within floor-fractured craters Anderson E and F on the lunar farside, isolated from other known similar deposits. Our search confirms that most major regional and localized low-albedo pyroclastic deposits have been identified on the Moon down to ~100 m/pix resolution, and that additional newly identified deposits are likely to be either isolated small deposits or additional portions of discontinuous, patchy deposits.
Phenology cameras observing boreal ecosystems of Finland
NASA Astrophysics Data System (ADS)
Peltoniemi, Mikko; Böttcher, Kristin; Aurela, Mika; Kolari, Pasi; Tanis, Cemal Melih; Linkosalmi, Maiju; Loehr, John; Metsämäki, Sari; Nadir Arslan, Ali
2016-04-01
Cameras have become useful tools for monitoring seasonality of ecosystems. Low-cost cameras facilitate validation of other measurements and allow extracting some key ecological features and moments from image time series. We installed a network of phenology cameras at selected ecosystem research sites in Finland. Cameras were installed above, on the level, or/and below the canopies. Current network hosts cameras taking time lapse images in coniferous and deciduous forests as well as at open wetlands offering thus possibilities to monitor various phenological and time-associated events and elements. In this poster, we present our camera network and give examples of image series use for research. We will show results about the stability of camera derived color signals, and based on that discuss about the applicability of cameras in monitoring time-dependent phenomena. We will also present results from comparisons between camera-derived color signal time series and daily satellite-derived time series (NVDI, NDWI, and fractional snow cover) from the Moderate Resolution Imaging Spectrometer (MODIS) at selected spruce and pine forests and in a wetland. We will discuss the applicability of cameras in supporting phenological observations derived from satellites, by considering the possibility of cameras to monitor both above and below canopy phenology and snow.
NASA Astrophysics Data System (ADS)
Nuster, Robert; Wurzinger, Gerhild; Paltauf, Guenther
2017-03-01
CCD camera based optical ultrasound detection is a promising alternative approach for high resolution 3D photoacoustic imaging (PAI). To fully exploit its potential and to achieve an image resolution <50 μm, it is necessary to incorporate variations of the speed of sound (SOS) in the image reconstruction algorithm. Hence, in the proposed work the idea and a first implementation are shown how speed of sound imaging can be added to a previously developed camera based PAI setup. The current setup provides SOS-maps with a spatial resolution of 2 mm and an accuracy of the obtained absolute SOS values of about 1%. The proposed dual-modality setup has the potential to provide highly resolved and perfectly co-registered 3D photoacoustic and SOS images.
Space telescope scientific instruments
NASA Technical Reports Server (NTRS)
Leckrone, D. S.
1979-01-01
The paper describes the Space Telescope (ST) observatory, the design concepts of the five scientific instruments which will conduct the initial observatory observations, and summarizes their astronomical capabilities. The instruments are the wide-field and planetary camera (WFPC) which will receive the highest quality images, the faint-object camera (FOC) which will penetrate to the faintest limiting magnitudes and achieve the finest angular resolution possible, and the faint-object spectrograph (FOS), which will perform photon noise-limited spectroscopy and spectropolarimetry on objects substantially fainter than those accessible to ground-based spectrographs. In addition, the high resolution spectrograph (HRS) will provide higher spectral resolution with greater photometric accuracy than previously possible in ultraviolet astronomical spectroscopy, and the high-speed photometer will achieve precise time-resolved photometric observations of rapidly varying astronomical sources on short time scales.
MSE spectrograph optical design: a novel pupil slicing technique
NASA Astrophysics Data System (ADS)
Spanò, P.
2014-07-01
The Maunakea Spectroscopic Explorer shall be mainly devoted to perform deep, wide-field, spectroscopic surveys at spectral resolutions from ~2000 to ~20000, at visible and near-infrared wavelengths. Simultaneous spectral coverage at low resolution is required, while at high resolution only selected windows can be covered. Moreover, very high multiplexing (3200 objects) must be obtained at low resolution. At higher resolutions a decreased number of objects (~800) can be observed. To meet such high demanding requirements, a fiber-fed multi-object spectrograph concept has been designed by pupil-slicing the collimated beam, followed by multiple dispersive and camera optics. Different resolution modes are obtained by introducing anamorphic lenslets in front of the fiber arrays. The spectrograph is able to switch between three resolution modes (2000, 6500, 20000) by removing the anamorphic lenses and exchanging gratings. Camera lenses are fixed in place to increase stability. To enhance throughput, VPH first-order gratings has been preferred over echelle gratings. Moreover, throughput is kept high over all wavelength ranges by splitting light into more arms by dichroic beamsplitters and optimizing efficiency for each channel by proper selection of glass materials, coatings, and grating parameters.
Toward a digital camera to rival the human eye
NASA Astrophysics Data System (ADS)
Skorka, Orit; Joseph, Dileepan
2011-07-01
All things considered, electronic imaging systems do not rival the human visual system despite notable progress over 40 years since the invention of the CCD. This work presents a method that allows design engineers to evaluate the performance gap between a digital camera and the human eye. The method identifies limiting factors of the electronic systems by benchmarking against the human system. It considers power consumption, visual field, spatial resolution, temporal resolution, and properties related to signal and noise power. A figure of merit is defined as the performance gap of the weakest parameter. Experimental work done with observers and cadavers is reviewed to assess the parameters of the human eye, and assessment techniques are also covered for digital cameras. The method is applied to 24 modern image sensors of various types, where an ideal lens is assumed to complete a digital camera. Results indicate that dynamic range and dark limit are the most limiting factors. The substantial functional gap, from 1.6 to 4.5 orders of magnitude, between the human eye and digital cameras may arise from architectural differences between the human retina, arranged in a multiple-layer structure, and image sensors, mostly fabricated in planar technologies. Functionality of image sensors may be significantly improved by exploiting technologies that allow vertical stacking of active tiers.
Slit-Slat Collimator Equipped Gamma Camera for Whole-Mouse SPECT-CT Imaging
NASA Astrophysics Data System (ADS)
Cao, Liji; Peter, Jörg
2012-06-01
A slit-slat collimator is developed for a gamma camera intended for small-animal imaging (mice). The tungsten housing of a roof-shaped collimator forms a slit opening, and the slats are made of lead foils separated by sparse polyurethane material. Alignment of the collimator with the camera's pixelated crystal is performed by adjusting a micrometer screw while monitoring a Co-57 point source for maximum signal intensity. For SPECT, the collimator forms a cylindrical field-of-view enabling whole mouse imaging with transaxial magnification and constant on-axis sensitivity over the entire axial direction. As the gamma camera is part of a multimodal imaging system incorporating also x-ray CT, five parameters corresponding to the geometric displacements of the collimator as well as to the mechanical co-alignment between the gamma camera and the CT subsystem are estimated by means of bimodal calibration sources. To illustrate the performance of the slit-slat collimator and to compare its performance to a single pinhole collimator, a Derenzo phantom study is performed. Transaxial resolution along the entire long axis is comparable to a pinhole collimator of same pinhole diameter. Axial resolution of the slit-slat collimator is comparable to that of a parallel beam collimator. Additionally, data from an in-vivo mouse study are presented.
A compact 16-module camera using 64-pixel CsI(Tl)/Si p-i-n photodiode imaging modules
NASA Astrophysics Data System (ADS)
Choong, W.-S.; Gruber, G. J.; Moses, W. W.; Derenzo, S. E.; Holland, S. E.; Pedrali-Noy, M.; Krieger, B.; Mandelli, E.; Meddeler, G.; Wang, N. W.; Witt, E. K.
2002-10-01
We present a compact, configurable scintillation camera employing a maximum of 16 individual 64-pixel imaging modules resulting in a 1024-pixel camera covering an area of 9.6 cm/spl times/9.6 cm. The 64-pixel imaging module consists of optically isolated 3 mm/spl times/3 mm/spl times/5 mm CsI(Tl) crystals coupled to a custom array of Si p-i-n photodiodes read out by a custom integrated circuit (IC). Each imaging module plugs into a readout motherboard that controls the modules and interfaces with a data acquisition card inside a computer. For a given event, the motherboard employs a custom winner-take-all IC to identify the module with the largest analog output and to enable the output address bits of the corresponding module's readout IC. These address bits identify the "winner" pixel within the "winner" module. The peak of the largest analog signal is found and held using a peak detect circuit, after which it is acquired by an analog-to-digital converter on the data acquisition card. The camera is currently operated with four imaging modules in order to characterize its performance. At room temperature, the camera demonstrates an average energy resolution of 13.4% full-width at half-maximum (FWHM) for the 140-keV emissions of /sup 99m/Tc. The system spatial resolution is measured using a capillary tube with an inner diameter of 0.7 mm and located 10 cm from the face of the collimator. Images of the line source in air exhibit average system spatial resolutions of 8.7- and 11.2-mm FWHM when using an all-purpose and high-sensitivity parallel hexagonal holes collimator, respectively. These values do not change significantly when an acrylic scattering block is placed between the line source and the camera.
Sensors for 3D Imaging: Metric Evaluation and Calibration of a CCD/CMOS Time-of-Flight Camera.
Chiabrando, Filiberto; Chiabrando, Roberto; Piatti, Dario; Rinaudo, Fulvio
2009-01-01
3D imaging with Time-of-Flight (ToF) cameras is a promising recent technique which allows 3D point clouds to be acquired at video frame rates. However, the distance measurements of these devices are often affected by some systematic errors which decrease the quality of the acquired data. In order to evaluate these errors, some experimental tests on a CCD/CMOS ToF camera sensor, the SwissRanger (SR)-4000 camera, were performed and reported in this paper. In particular, two main aspects are treated: the calibration of the distance measurements of the SR-4000 camera, which deals with evaluation of the camera warm up time period, the distance measurement error evaluation and a study of the influence on distance measurements of the camera orientation with respect to the observed object; the second aspect concerns the photogrammetric calibration of the amplitude images delivered by the camera using a purpose-built multi-resolution field made of high contrast targets.
NASA Technical Reports Server (NTRS)
Ivanov, Anton B.
2003-01-01
The Mars Orbiter Camera (MOC) has been operating on board of the Mars Global Surveyor (MGS) spacecraft since 1998. It consists of three cameras - Red and Blue Wide Angle cameras (FOV=140 deg.) and Narrow Angle camera (FOV=0.44 deg.). The Wide Angle camera allows surface resolution down to 230 m/pixel and the Narrow Angle camera - down to 1.5 m/pixel. This work is a continuation of the project, which we have reported previously. Since then we have refined and improved our stereo correlation algorithm and have processed many more stereo pairs. We will discuss results of our stereo pair analysis located in the Mars Exploration rovers (MER) landing sites and address feasibility of recovering topography from stereo pairs (especially in the polar regions), taken during MGS 'Relay-16' mode.
Evaluation of a ''CMOS'' Imager for Shadow Mask Hard X-ray Telescope
NASA Technical Reports Server (NTRS)
Desai, Upendra D.; Orwig, Larry E.; Oergerle, William R. (Technical Monitor)
2002-01-01
We have developed a hard x-ray coder that provides high angular resolution imaging capability using a coarse position sensitive image plane detector. The coder consists of two Fresnel zone plates. (FZP) Two such 'FZP's generate Moire fringe patterns whose frequency and orientation define the arrival direction of a beam with respect to telescope axis. The image plane detector needs to resolve the Moire fringe pattern. Pixilated detectors can be used as an image plane detector. The recently available 'CMOS' imager could provide a very low power large area image plane detector for hard x-rays. We have looked into a unit made by Rad-Icon Imaging Corp. The Shadow-Box 1024 x-ray camera is a high resolution 1024xl024 pixel detector of 50x50 mm area. It is a very low power, stand alone camera. We present some preliminary results of our investigation of evaluation of such camera.
Measuring high-resolution sky luminance distributions with a CCD camera.
Tohsing, Korntip; Schrempf, Michael; Riechelmann, Stefan; Schilke, Holger; Seckmeyer, Gunther
2013-03-10
We describe how sky luminance can be derived from a newly developed hemispherical sky imager (HSI) system. The system contains a commercial compact charge coupled device (CCD) camera equipped with a fish-eye lens. The projection of the camera system has been found to be nearly equidistant. The luminance from the high dynamic range images has been calculated and then validated with luminance data measured by a CCD array spectroradiometer. The deviation between both datasets is less than 10% for cloudless and completely overcast skies, and differs by no more than 20% for all sky conditions. The global illuminance derived from the HSI pictures deviates by less than 5% and 20% under cloudless and cloudy skies for solar zenith angles less than 80°, respectively. This system is therefore capable of measuring sky luminance with the high spatial and temporal resolution of more than a million pixels and every 20 s respectively.
In-vessel visible inspection system on KSTAR
NASA Astrophysics Data System (ADS)
Chung, Jinil; Seo, D. C.
2008-08-01
To monitor the global formation of the initial plasma and damage to the internal structures of the vacuum vessel, an in-vessel visible inspection system has been installed and operated on the Korean superconducting tokamak advanced research (KSTAR) device. It consists of four inspection illuminators and two visible/H-alpha TV cameras. Each illuminator uses four 150W metal-halide lamps with separate lamp controllers, and programmable progressive scan charge-coupled device cameras with 1004×1004 resolution at 48frames/s and a resolution of 640×480 at 210frames/s are used to capture images. In order to provide vessel inspection capability under any operation condition, the lamps and cameras are fully controlled from the main control room and protected by shutters from deposits during plasma operation. In this paper, we describe the design and operation results of the visible inspection system with the images of the KSTAR Ohmic discharges during the first plasma campaign.
Deflection Measurements of a Thermally Simulated Nuclear Core Using a High-Resolution CCD-Camera
NASA Technical Reports Server (NTRS)
Stanojev, B. J.; Houts, M.
2004-01-01
Space fission systems under consideration for near-term missions all use compact. fast-spectrum reactor cores. Reactor dimensional change with increasing temperature, which affects neutron leakage. is the dominant source of reactivity feedback in these systems. Accurately measuring core dimensional changes during realistic non-nuclear testing is therefore necessary in predicting the system nuclear equivalent behavior. This paper discusses one key technique being evaluated for measuring such changes. The proposed technique is to use a Charged Couple Device (CCD) sensor to obtain deformation readings of electrically heated prototypic reactor core geometry. This paper introduces a technique by which a single high spatial resolution CCD camera is used to measure core deformation in Real-Time (RT). Initial system checkout results are presented along with a discussion on how additional cameras could be used to achieve a three- dimensional deformation profile of the core during test.
NASA Astrophysics Data System (ADS)
Aishwariya, A.; Pallavi Sudhir, Gulavani; Garg, Nemesa; Karthikeyan, B.
2017-11-01
A body worn camera is small video camera worn on the body, typically used by police officers to record arrests, evidence from crime scenes. It helps preventing and resolving complaints brought by members of the public; and strengthening police transparency, performance, and accountability. The main constants of this type of the system are video format, resolution, frames rate, and audio quality. This system records the video in .mp4 format with 1080p resolution and 30 frames per second. One more important aspect to while designing this system is amount of power the system requires as battery management becomes very critical. The main design challenges are Size of the Video, Audio for the video. Combining both audio and video and saving it in .mp4 format, Battery, size that is required for 8 hours of continuous recording, Security. For prototyping this system is implemented using Raspberry Pi model B.
Investigating plasma viscosity with fast framing photography in the ZaP-HD Flow Z-Pinch experiment
NASA Astrophysics Data System (ADS)
Weed, Jonathan Robert
The ZaP-HD Flow Z-Pinch experiment investigates the stabilizing effect of sheared axial flows while scaling toward a high-energy-density laboratory plasma (HEDLP > 100 GPa). Stabilizing flows may persist until viscous forces dissipate a sheared flow profile. Plasma viscosity is investigated by measuring scale lengths in turbulence intentionally introduced in the plasma flow. A boron nitride turbulence-tripping probe excites small scale length turbulence in the plasma, and fast framing optical cameras are used to study time-evolved turbulent structures and viscous dissipation. A Hadland Imacon 790 fast framing camera is modified for digital image capture, but features insufficient resolution to study turbulent structures. A Shimadzu HPV-X camera captures the evolution of turbulent structures with great spatial and temporal resolution, but is unable to resolve the anticipated Kolmogorov scale in ZaP-HD as predicted by a simplified pinch model.
NASA Astrophysics Data System (ADS)
McMackin, Lenore; Herman, Matthew A.; Weston, Tyler
2016-02-01
We present the design of a multi-spectral imager built using the architecture of the single-pixel camera. The architecture is enabled by the novel sampling theory of compressive sensing implemented optically using the Texas Instruments DLP™ micro-mirror array. The array not only implements spatial modulation necessary for compressive imaging but also provides unique diffractive spectral features that result in a multi-spectral, high-spatial resolution imager design. The new camera design provides multi-spectral imagery in a wavelength range that extends from the visible to the shortwave infrared without reduction in spatial resolution. In addition to the compressive imaging spectrometer design, we present a diffractive model of the architecture that allows us to predict a variety of detailed functional spatial and spectral design features. We present modeling results, architectural design and experimental results that prove the concept.
Quantitative Imaging with a Mobile Phone Microscope
Skandarajah, Arunan; Reber, Clay D.; Switz, Neil A.; Fletcher, Daniel A.
2014-01-01
Use of optical imaging for medical and scientific applications requires accurate quantification of features such as object size, color, and brightness. High pixel density cameras available on modern mobile phones have made photography simple and convenient for consumer applications; however, the camera hardware and software that enables this simplicity can present a barrier to accurate quantification of image data. This issue is exacerbated by automated settings, proprietary image processing algorithms, rapid phone evolution, and the diversity of manufacturers. If mobile phone cameras are to live up to their potential to increase access to healthcare in low-resource settings, limitations of mobile phone–based imaging must be fully understood and addressed with procedures that minimize their effects on image quantification. Here we focus on microscopic optical imaging using a custom mobile phone microscope that is compatible with phones from multiple manufacturers. We demonstrate that quantitative microscopy with micron-scale spatial resolution can be carried out with multiple phones and that image linearity, distortion, and color can be corrected as needed. Using all versions of the iPhone and a selection of Android phones released between 2007 and 2012, we show that phones with greater than 5 MP are capable of nearly diffraction-limited resolution over a broad range of magnifications, including those relevant for single cell imaging. We find that automatic focus, exposure, and color gain standard on mobile phones can degrade image resolution and reduce accuracy of color capture if uncorrected, and we devise procedures to avoid these barriers to quantitative imaging. By accommodating the differences between mobile phone cameras and the scientific cameras, mobile phone microscopes can be reliably used to increase access to quantitative imaging for a variety of medical and scientific applications. PMID:24824072
640x480 PtSi Stirling-cooled camera system
NASA Astrophysics Data System (ADS)
Villani, Thomas S.; Esposito, Benjamin J.; Davis, Timothy J.; Coyle, Peter J.; Feder, Howard L.; Gilmartin, Harvey R.; Levine, Peter A.; Sauer, Donald J.; Shallcross, Frank V.; Demers, P. L.; Smalser, P. J.; Tower, John R.
1992-09-01
A Stirling cooled 3 - 5 micron camera system has been developed. The camera employs a monolithic 640 X 480 PtSi-MOS focal plane array. The camera system achieves an NEDT equals 0.10 K at 30 Hz frame rate with f/1.5 optics (300 K background). At a spatial frequency of 0.02 cycles/mRAD the vertical and horizontal Minimum Resolvable Temperature are in the range of MRT equals 0.03 K (f/1.5 optics, 300 K background). The MOS focal plane array achieves a resolution of 480 TV lines per picture height independent of background level and position within the frame.
Evaluation of the MSFC facsimile camera system as a tool for extraterrestrial geologic exploration
NASA Technical Reports Server (NTRS)
Wolfe, E. W.; Alderman, J. D.
1971-01-01
Utility of the Marshall Space Flight (MSFC) facsimile camera system for extraterrestrial geologic exploration was investigated during the spring of 1971 near Merriam Crater in northern Arizona. Although the system with its present hard-wired recorder operates erratically, the imagery showed that the camera could be developed as a prime imaging tool for automated missions. Its utility would be enhanced by development of computer techniques that utilize digital camera output for construction of topographic maps, and it needs increased resolution for examining near field details. A supplementary imaging system may be necessary for hand specimen examination at low magnification.
The mosaics of Mars: As seen by the Viking Lander cameras
NASA Technical Reports Server (NTRS)
Levinthal, E. C.; Jones, K. L.
1980-01-01
The mosaics and derivative products produced from many individual high resolution images acquired by the Viking Lander Camera Systems are described: A morning and afternoon mosaic for both cameras at the Lander 1 Chryse Planitia site, and a morning, noon, and afternoon camera pair at Utopia Planitia, the Lander 11 site. The derived products include special geometric projections of the mosaic data sets, polar stereographic (donut), stereoscopic, and orthographic. Contour maps and vertical profiles of the topography were overlaid on the mosaics from which they were derived. Sets of stereo pairs were extracted and enlarged from stereoscopic projections of the mosaics.
Astronaut Kathryn Thornton on HST photographed by Electronic Still Camera
1993-12-05
S61-E-011 (5 Dec 1993) --- This view of astronaut Kathryn C. Thornton working on the Hubble Space Telescope (HST) was photographed with an Electronic Still Camera (ESC), and down linked to ground controllers soon afterward. Thornton, anchored to the end of the Remote Manipulator System (RMS) arm, is installing the +V2 Solar Array Panel as a replacement for the original one removed earlier. Electronic still photography is a relatively new technology which provides the means for a handheld camera to electronically capture and digitize an image with resolution approaching film quality. The electronic still camera has flown as an experiment on several other shuttle missions.
UAV-based NDVI calculation over grassland: An alternative approach
NASA Astrophysics Data System (ADS)
Mejia-Aguilar, Abraham; Tomelleri, Enrico; Asam, Sarah; Zebisch, Marc
2016-04-01
The Normalised Difference Vegetation Index (NDVI) is one of the most widely used indicators for monitoring and assessing vegetation in remote sensing. The index relies on the reflectance difference between the near infrared (NIR) and red light and is thus able to track variations of structural, phenological, and biophysical parameters for seasonal and long-term monitoring. Conventionally, NDVI is inferred from space-borne spectroradiometers, such as MODIS, with moderate resolution up to 250 m ground resolution. In recent years, a new generation of miniaturized radiometers and integrated hyperspectral sensors with high resolution became available. Such small and light instruments are particularly adequate to be mounted on airborne unmanned aerial vehicles (UAV) used for monitoring services reaching ground sampling resolution in the order of centimetres. Nevertheless, such miniaturized radiometers and hyperspectral sensors are still very expensive and require high upfront capital costs. Therefore, we propose an alternative, mainly cheaper method to calculate NDVI using a camera constellation consisting of two conventional consumer-grade cameras: (i) a Ricoh GR modified camera that acquires the NIR spectrum by removing the internal infrared filter. A mounted optical filter additionally obstructs all wavelengths below 700 nm. (ii) A Ricoh GR in RGB configuration using two optical filters for blocking wavelengths below 600 nm as well as NIR and ultraviolet (UV) light. To assess the merit of the proposed method, we carry out two comparisons: First, reflectance maps generated by the consumer-grade camera constellation are compared to reflectance maps produced with a hyperspectral camera (Rikola). All imaging data and reflectance maps are processed using the PIX4D software. In the second test, the NDVI at specific points of interest (POI) generated by the consumer-grade camera constellation is compared to NDVI values obtained by ground spectral measurements using a portable spectroradiometer (Spectravista SVC HR-1024i). All data were collected on a dry alpine mountain grassland site in the Matsch valley, Italy, during the vegetation period of 2015. Data acquisition for the first comparison followed a pre-programmed flight plan in which the hyperspectral and alternative dual-camera constellation were mounted separately on an octocopter-UAV during two consecutive flight campaigns. Ground spectral measurements collection took place on the same site and on the same dates (three in total) of the flight campaigns. The proposed technique achieves promising results and therewith constitutes a cheap and simple way of collecting spatially explicit information on vegetated areas even in challenging terrain.
Chen, Brian R; Poon, Emily; Alam, Murad
2017-08-01
Photographs are an essential tool for the documentation and sharing of findings in dermatologic surgery, and various camera types are available. To evaluate the currently available camera types in view of the special functional needs of procedural dermatologists. Mobile phone, point and shoot, digital single-lens reflex (DSLR), digital medium format, and 3-dimensional cameras were compared in terms of their usefulness for dermatologic surgeons. For each camera type, the image quality, as well as the other practical benefits and limitations, were evaluated with reference to a set of ideal camera characteristics. Based on these assessments, recommendations were made regarding the specific clinical circumstances in which each camera type would likely be most useful. Mobile photography may be adequate when ease of use, availability, and accessibility are prioritized. Point and shoot cameras and DSLR cameras provide sufficient resolution for a range of clinical circumstances, while providing the added benefit of portability. Digital medium format cameras offer the highest image quality, with accurate color rendition and greater color depth. Three-dimensional imaging may be optimal for the definition of skin contour. The selection of an optimal camera depends on the context in which it will be used.
NASA Astrophysics Data System (ADS)
Schultz, C. J.; Lang, T. J.; Leake, S.; Runco, M.; Blakeslee, R. J.
2017-12-01
Video and still frame images from cameras aboard the International Space Station (ISS) are used to inspire, educate, and provide a unique vantage point from low-Earth orbit that is second to none; however, these cameras have overlooked capabilities for contributing to scientific analysis of the Earth and near-space environment. The goal of this project is to study how georeferenced video/images from available ISS camera systems can be useful for scientific analysis, using lightning properties as a demonstration. Camera images from the crew cameras and high definition video from the Chiba University Meteor Camera were combined with lightning data from the National Lightning Detection Network (NLDN), ISS-Lightning Imaging Sensor (ISS-LIS), the Geostationary Lightning Mapper (GLM) and lightning mapping arrays. These cameras provide significant spatial resolution advantages ( 10 times or better) over ISS-LIS and GLM, but with lower temporal resolution. Therefore, they can serve as a complementarity analysis tool for studying lightning and thunderstorm processes from space. Lightning sensor data, Visible Infrared Imaging Radiometer Suite (VIIRS) derived city light maps, and other geographic databases were combined with the ISS attitude and position data to reverse geolocate each image or frame. An open-source Python toolkit has been developed to assist with this effort. Next, the locations and sizes of all flashes in each frame or image were computed and compared with flash characteristics from all available lightning datasets. This allowed for characterization of cloud features that are below the 4-km and 8-km resolution of ISS-LIS and GLM which may reduce the light that reaches the ISS-LIS or GLM sensor. In the case of video, consecutive frames were overlaid to determine the rate of change of the light escaping cloud top. Characterization of the rate of change in geometry, more generally the radius, of light escaping cloud top was integrated with the NLDN, ISS-LIS and GLM to understand how the peak rate of change and the peak area of each flash aligned with each lightning system in time. Flash features like leaders could be inferred from the video frames as well. Testing is being done to see if leader speeds may be accurately calculated under certain circumstances.
High speed, real-time, camera bandwidth converter
Bower, Dan E; Bloom, David A; Curry, James R
2014-10-21
Image data from a CMOS sensor with 10 bit resolution is reformatted in real time to allow the data to stream through communications equipment that is designed to transport data with 8 bit resolution. The incoming image data has 10 bit resolution. The communication equipment can transport image data with 8 bit resolution. Image data with 10 bit resolution is transmitted in real-time, without a frame delay, through the communication equipment by reformatting the image data.
NASA Astrophysics Data System (ADS)
Karovska, Margarita
2003-09-01
The nearby system Mira AB composed of an aging AGB star (Mira A) and a WD companion (Mira B) offers a unique laboratory for studying wind accretion processes, a poorly understood phenomenon in many sources. Recent Chandra ACIS-S Obs.(70ks on 12/6/03; PI.M.Karovska) resolved for the first time the components (~0.6") in X-rays, and detected a new bright soft source (< 0.7 keV) in addition to the harder (1-4 keV) emission from Mira B. The new source is spatially and spectrally separated from Mira B and likely associated with Mira A. This is the first detection of X-rays from an AGB star. This source was not detected by ROSAT in 1993 or recently by XMM 8/03 (AAS/03,J.Kastner), and could be a transient phenomenon. Model fitting shows that the soft X-ray emission is likely several emission lines, rather then a continuum; with ACIS spectral resolution we cannot resolve or identify these lines. We propose a 40ks LETG+HRC-S obs. to identify the lines and determine the emission mechanism.
Quality controls for gamma cameras and PET cameras: development of a free open-source ImageJ program
NASA Astrophysics Data System (ADS)
Carlier, Thomas; Ferrer, Ludovic; Berruchon, Jean B.; Cuissard, Regis; Martineau, Adeline; Loonis, Pierre; Couturier, Olivier
2005-04-01
Acquisition data and treatments for quality controls of gamma cameras and Positron Emission Tomography (PET) cameras are commonly performed with dedicated program packages, which are running only on manufactured computers and differ from each other, depending on camera company and program versions. The aim of this work was to develop a free open-source program (written in JAVA language) to analyze data for quality control of gamma cameras and PET cameras. The program is based on the free application software ImageJ and can be easily loaded on any computer operating system (OS) and thus on any type of computer in every nuclear medicine department. Based on standard parameters of quality control, this program includes 1) for gamma camera: a rotation center control (extracted from the American Association of Physics in Medicine, AAPM, norms) and two uniformity controls (extracted from the Institute of Physics and Engineering in Medicine, IPEM, and National Electronic Manufacturers Association, NEMA, norms). 2) For PET systems, three quality controls recently defined by the French Medical Physicist Society (SFPM), i.e. spatial resolution and uniformity in a reconstructed slice and scatter fraction, are included. The determination of spatial resolution (thanks to the Point Spread Function, PSF, acquisition) allows to compute the Modulation Transfer Function (MTF) in both modalities of cameras. All the control functions are included in a tool box which is a free ImageJ plugin and could be soon downloaded from Internet. Besides, this program offers the possibility to save on HTML format the uniformity quality control results and a warning can be set to automatically inform users in case of abnormal results. The architecture of the program allows users to easily add any other specific quality control program. Finally, this toolkit is an easy and robust tool to perform quality control on gamma cameras and PET cameras based on standard computation parameters, is free, run on any type of computer and will soon be downloadable from the net (http://rsb.info.nih.gov/ij/plugins or http://nucleartoolkit.free.fr).
"Stereo Compton cameras" for the 3-D localization of radioisotopes
NASA Astrophysics Data System (ADS)
Takeuchi, K.; Kataoka, J.; Nishiyama, T.; Fujita, T.; Kishimoto, A.; Ohsuka, S.; Nakamura, S.; Adachi, S.; Hirayanagi, M.; Uchiyama, T.; Ishikawa, Y.; Kato, T.
2014-11-01
The Compton camera is a viable and convenient tool used to visualize the distribution of radioactive isotopes that emit gamma rays. After the nuclear disaster in Fukushima in 2011, there is a particularly urgent need to develop "gamma cameras", which can visualize the distribution of such radioisotopes. In response, we propose a portable Compton camera, which comprises 3-D position-sensitive GAGG scintillators coupled with thin monolithic MPPC arrays. The pulse-height ratio of two MPPC-arrays allocated at both ends of the scintillator block determines the depth of interaction (DOI), which dramatically improves the position resolution of the scintillation detectors. We report on the detailed optimization of the detector design, based on Geant4 simulation. The results indicate that detection efficiency reaches up to 0.54%, or more than 10 times that of other cameras being tested in Fukushima, along with a moderate angular resolution of 8.1° (FWHM). By applying the triangular surveying method, we also propose a new concept for the stereo measurement of gamma rays by using two Compton cameras, thus enabling the 3-D positional measurement of radioactive isotopes for the first time. From one point source simulation data, we ensured that the source position and the distance to the same could be determined typically to within 2 meters' accuracy and we also confirmed that more than two sources are clearly separated by the event selection from two point sources of simulation data.
Film cameras or digital sensors? The challenge ahead for aerial imaging
Light, D.L.
1996-01-01
Cartographic aerial cameras continue to play the key role in producing quality products for the aerial photography business, and specifically for the National Aerial Photography Program (NAPP). One NAPP photograph taken with cameras capable of 39 lp/mm system resolution can contain the equivalent of 432 million pixels at 11 ??m spot size, and the cost is less than $75 per photograph to scan and output the pixels on a magnetic storage medium. On the digital side, solid state charge coupled device linear and area arrays can yield quality resolution (7 to 12 ??m detector size) and a broader dynamic range. If linear arrays are to compete with film cameras, they will require precise attitude and positioning of the aircraft so that the lines of pixels can be unscrambled and put into a suitable homogeneous scene that is acceptable to an interpreter. Area arrays need to be much larger than currently available to image scenes competitive in size with film cameras. Analysis of the relative advantages and disadvantages of the two systems show that the analog approach is more economical at present. However, as arrays become larger, attitude sensors become more refined, global positioning system coordinate readouts become commonplace, and storage capacity becomes more affordable, the digital camera may emerge as the imaging system for the future. Several technical challenges must be overcome if digital sensors are to advance to where they can support mapping, charting, and geographic information system applications.
Investigation into the use of photoanthropometry in facial image comparison.
Moreton, Reuben; Morley, Johanna
2011-10-10
Photoanthropometry is a metric based facial image comparison technique. Measurements of the face are taken from an image using predetermined facial landmarks. Measurements are then converted to proportionality indices (PIs) and compared to PIs from another facial image. Photoanthropometry has been presented as a facial image comparison technique in UK courts for over 15 years. It is generally accepted that extrinsic factors (e.g. orientation of the head, camera angle and distance from the camera) can cause discrepancies in anthropometric measurements of the face from photographs. However there has been limited empirical research into quantifying the influence of such variables. The aim of this study was to determine the reliability of photoanthropometric measurements between different images of the same individual taken with different angulations of the camera. The study examined the facial measurements of 25 individuals from high resolution photographs, taken at different horizontal and vertical camera angles in a controlled environment. Results show that the degree of variability in facial measurements of the same individual due to variations in camera angle can be as great as the variability of facial measurements between different individuals. Results suggest that photoanthropometric facial comparison, as it is currently practiced, is unsuitable for elimination purposes. Preliminary investigations into the effects of distance from camera and image resolution in poor quality images suggest that such images are not an accurate representation of an individuals face, however further work is required. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Agostini, Denis; Marie, Pierre-Yves; Ben-Haim, Simona; Rouzet, François; Songy, Bernard; Giordano, Alessandro; Gimelli, Alessia; Hyafil, Fabien; Sciagrà, Roberto; Bucerius, Jan; Verberne, Hein J; Slart, Riemer H J A; Lindner, Oliver; Übleis, Christopher; Hacker, Marcus
2016-12-01
The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.
Zhao, Qiaole; Schelen, Ben; Schouten, Raymond; van den Oever, Rein; Leenen, René; van Kuijk, Harry; Peters, Inge; Polderdijk, Frank; Bosiers, Jan; Raspe, Marcel; Jalink, Kees; Geert Sander de Jong, Jan; van Geest, Bert; Stoop, Karel; Young, Ian Ted
2012-12-01
We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device design in a frequency-domain FLIM system. The first stage of evaluation for the camera has been carried out. Camera characteristics such as noise distribution, dark current influence, camera gain, sampling density, sensitivity, linearity of photometric response, and optical transfer function have been studied through experiments. We are able to do lifetime measurement using our modulated, electron-multiplied fluorescence lifetime imaging microscope (MEM-FLIM) camera for various objects, e.g., fluorescein solution, fixed green fluorescent protein (GFP) cells, and GFP-actin stained live cells. A detailed comparison of a conventional microchannel plate (MCP)-based FLIM system and the MEM-FLIM system is presented. The MEM-FLIM camera shows higher resolution and a better image quality. The MEM-FLIM camera provides a new opportunity for performing frequency-domain FLIM.
Raspberry Pi camera with intervalometer used as crescograph
NASA Astrophysics Data System (ADS)
Albert, Stefan; Surducan, Vasile
2017-12-01
The intervalometer is an attachment or facility on a photo-camera that operates the shutter regularly at set intervals over a period. Professional cameras with built in intervalometers are expensive and quite difficult to find. The Canon CHDK open source operating system allows intervalometer implementation on Canon cameras only. However finding a Canon camera with near infra-red (NIR) photographic lens at affordable price is impossible. On experiments requiring several cameras (used to measure growth in plants - the crescographs, but also for coarse evaluation of the water content of leaves), the costs of the equipment are often over budget. Using two Raspberry Pi modules each equipped with a low cost NIR camera and a WIFI adapter (for downloading pictures stored on the SD card) and some freely available software, we have implemented two low budget intervalometer cameras. The shutting interval, the number of pictures to be taken, image resolution and some other parameters can be fully programmed. Cameras have been in use continuously for three months (July-October 2017) in a relevant environment (outside), proving the concept functionality.
Compton camera study for high efficiency SPECT and benchmark with Anger system
NASA Astrophysics Data System (ADS)
Fontana, M.; Dauvergne, D.; Létang, J. M.; Ley, J.-L.; Testa, É.
2017-12-01
Single photon emission computed tomography (SPECT) is at present one of the major techniques for non-invasive diagnostics in nuclear medicine. The clinical routine is mostly based on collimated cameras, originally proposed by Hal Anger. Due to the presence of mechanical collimation, detection efficiency and energy acceptance are limited and fixed by the system’s geometrical features. In order to overcome these limitations, the application of Compton cameras for SPECT has been investigated for several years. In this study we compare a commercial SPECT-Anger device, the General Electric HealthCare Infinia system with a High Energy General Purpose (HEGP) collimator, and the Compton camera prototype under development by the French collaboration CLaRyS, through Monte Carlo simulations (GATE—GEANT4 Application for Tomographic Emission—version 7.1 and GEANT4 version 9.6, respectively). Given the possible introduction of new radio-emitters at higher energies intrinsically allowed by the Compton camera detection principle, the two detectors are exposed to point-like sources at increasing primary gamma energies, from actual isotopes already suggested for nuclear medicine applications. The Compton camera prototype is first characterized for SPECT application by studying the main parameters affecting its imaging performance: detector energy resolution and random coincidence rate. The two detector performances are then compared in terms of radial event distribution, detection efficiency and final image, obtained by gamma transmission analysis for the Anger system, and with an iterative List Mode-Maximum Likelihood Expectation Maximization (LM-MLEM) algorithm for the Compton reconstruction. The results show for the Compton camera a detection efficiency increased by a factor larger than an order of magnitude with respect to the Anger camera, associated with an enhanced spatial resolution for energies beyond 500 keV. We discuss the advantages of Compton camera application for SPECT if compared to present commercial Anger systems, with particular focus on dose delivered to the patient, examination time, and spatial uncertainties.
SU-D-BRC-07: System Design for a 3D Volumetric Scintillation Detector Using SCMOS Cameras
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darne, C; Robertson, D; Alsanea, F
2016-06-15
Purpose: The purpose of this project is to build a volumetric scintillation detector for quantitative imaging of 3D dose distributions of proton beams accurately in near real-time. Methods: The liquid scintillator (LS) detector consists of a transparent acrylic tank (20×20×20 cm{sup 3}) filled with a liquid scintillator that when irradiated with protons generates scintillation light. To track rapid spatial and dose variations in spot scanning proton beams we used three scientific-complementary metal-oxide semiconductor (sCMOS) imagers (2560×2160 pixels). The cameras collect optical signal from three orthogonal projections. To reduce system footprint two mirrors oriented at 45° to the tank surfaces redirectmore » scintillation light to cameras for capturing top and right views. Selection of fixed focal length objective lenses for these cameras was based on their ability to provide large depth of field (DoF) and required field of view (FoV). Multiple cross-hairs imprinted on the tank surfaces allow for image corrections arising from camera perspective and refraction. Results: We determined that by setting sCMOS to 16-bit dynamic range, truncating its FoV (1100×1100 pixels) to image the entire volume of the LS detector, and using 5.6 msec integration time imaging rate can be ramped up to 88 frames per second (fps). 20 mm focal length lens provides a 20 cm imaging DoF and 0.24 mm/pixel resolution. Master-slave camera configuration enable the slaves to initiate image acquisition instantly (within 2 µsec) after receiving a trigger signal. A computer with 128 GB RAM was used for spooling images from the cameras and can sustain a maximum recording time of 2 min per camera at 75 fps. Conclusion: The three sCMOS cameras are capable of high speed imaging. They can therefore be used for quick, high-resolution, and precise mapping of dose distributions from scanned spot proton beams in three dimensions.« less
The LST scientific instruments
NASA Technical Reports Server (NTRS)
Levin, G. M.
1975-01-01
Seven scientific instruments are presently being studied for use with the Large Space Telescope (LST). These instruments are the F/24 Field Camera, the F/48-F/96 Planetary Camera, the High Resolution Spectrograph, the Faint Object Spectrograph, the Infrared Photometer, and the Astrometer. These instruments are being designed as facility instruments to be replaceable during the life of the Observatory.
Lightweight Electronic Camera for Research on Clouds
NASA Technical Reports Server (NTRS)
Lawson, Paul
2006-01-01
"Micro-CPI" (wherein "CPI" signifies "cloud-particle imager") is the name of a small, lightweight electronic camera that has been proposed for use in research on clouds. It would acquire and digitize high-resolution (3- m-pixel) images of ice particles and water drops at a rate up to 1,000 particles (and/or drops) per second.
NASA Astrophysics Data System (ADS)
Buongiorno, M. F.; Musacchio, M.; Silvestri, M.; Vilardo, G.; Sansivero, F.; caPUTO, T.; bellucci Sessa, E.; Pieri, D. C.
2017-12-01
Current satellite missions providing imagery in the TIR region at high spatial resolution offer the possibility to estimate the surface temperature in volcanic area contributing in understanding the ongoing phenomena to mitigate the volcanic risk when population are exposed. The Campi Flegrei volcanic area (Italy) is part of the Napolitan volcanic district and its monitored by INGV ground networks including thermal cameras. TIRS on LANDSAT and ASTER on NASA-TERRA provide thermal IR channels to monitor the evolution of the surface temperatures on Campi Flegrei area. The spatial resolution of the TIR data is 100 m for LANDSAT8 and 90 m for ASTER, temporal resolution is 16 days for both satellites. TIRNet network has been developed by INGV for long-term volcanic surveillance of the Flegrei Fields through the acquisition of thermal infrared images. The system is currently comprised of 5 permanent stations equipped with FLIR A645SC thermo cameras with a 640x480 resolution IR sensor. To improve the systematic use of satellite data in the monitor procedures of Volcanic Observatories a suitable integration and validation strategy is needed, also considering that current satellite missions do not provide TIR data with optimal characteristics to observe small thermal anomalies that may indicate changes in the volcanic activity. The presented procedure has been applied to the analysis of Solfatara Crater and is based on 2 different steps: 1) parallel processing chains to produce ground temperature data both from satellite and ground cameras; 2) data integration and comparison. The ground cameras images generally correspond to views of portion of the crater slopes characterized by significant thermal anomalies due to fumarole fields. In order to compare the satellite and ground cameras it has been necessary to take into account the observation geometries. All thermal images of the TIRNet have been georeferenced to the UTM WGS84 system, a regular grid of 30x30 meters has been created to select polygonal areas corresponding only to the cells containing the georeferenced TIR images acquired by different TIRnet stations. Preliminary results of this integration approach has been analyzed in order to produce systematic reports to the Italian Civil Protection for the Napolitan Volcanoes.
Webb, Donna J.; Brown, Claire M.
2012-01-01
Epi-fluorescence microscopy is available in most life sciences research laboratories, and when optimized can be a central laboratory tool. In this chapter, the epi-fluorescence light path is introduced and the various components are discussed in detail. Recommendations are made for incident lamp light sources, excitation and emission filters, dichroic mirrors, objective lenses, and charge-coupled device (CCD) cameras in order to obtain the most sensitive epi-fluorescence microscope. The even illumination of metal-halide lamps combined with new “hard” coated filters and mirrors, a high resolution monochrome CCD camera, and a high NA objective lens are all recommended for high resolution and high sensitivity fluorescence imaging. Recommendations are also made for multicolor imaging with the use of monochrome cameras, motorized filter turrets, individual filter cubes, and corresponding dyes that are the best choice for sensitive, high resolution multicolor imaging. Images should be collected using Nyquist sampling and should be corrected for background intensity contributions and nonuniform illumination across the field of view. Photostable fluorescent probes and proteins that absorb a lot of light (i.e., high extinction co-efficients) and generate a lot of fluorescence signal (i.e., high quantum yields) are optimal. A neuronal immune-fluorescence labeling protocol is also presented. Finally, in order to maximize the utility of sensitive wide-field microscopes and generate the highest resolution images with high signal-to-noise, advice for combining wide-field epi-fluorescence imaging with restorative image deconvolution is presented. PMID:23026996
NASA Astrophysics Data System (ADS)
Seo, Hokuto; Aihara, Satoshi; Namba, Masakazu; Watabe, Toshihisa; Ohtake, Hiroshi; Kubota, Misao; Egami, Norifumi; Hiramatsu, Takahiro; Matsuda, Tokiyoshi; Furuta, Mamoru; Nitta, Hiroshi; Hirao, Takashi
2010-01-01
Our group has been developing a new type of image sensor overlaid with three organic photoconductive films, which are individually sensitive to only one of the primary color components (blue (B), green (G), or red (R) light), with the aim of developing a compact, high resolution color camera without any color separation optical systems. In this paper, we firstly revealed the unique characteristics of organic photoconductive films. Only choosing organic materials can tune the photoconductive properties of the film, especially excellent wavelength selectivities which are good enough to divide the incident light into three primary colors. Color separation with vertically stacked organic films was also shown. In addition, the high-resolution of organic photoconductive films sufficient for high-definition television (HDTV) was confirmed in a shooting experiment using a camera tube. Secondly, as a step toward our goal, we fabricated a stacked organic image sensor with G- and R-sensitive organic photoconductive films, each of which had a zinc oxide (ZnO) thin film transistor (TFT) readout circuit, and demonstrated image pickup at a TV frame rate. A color image with a resolution corresponding to the pixel number of the ZnO TFT readout circuit was obtained from the stacked image sensor. These results show the potential for the development of high-resolution prism-less color cameras with stacked organic photoconductive films.
NASA Technical Reports Server (NTRS)
Tarbell, T.; Frank, Z.; Gilbreth, C.; Shine, R.; Title, A.; Topka, K.; Wolfson, J.
1989-01-01
SOUP is a versatile, visible-light solar observatory, built for space or balloon flight. It is designed to study magnetic and velocity fields in the solar atmosphere with high spatial resolution and temporal uniformity, which cannot be achieved from the surface of the earth. The SOUP investigation is carried out by the Lockheed Palo Alto Research Laboratory, under contract to NASA's Marshall Space Flight Center. Co-investigators include staff members at a dozen observatories and universities in the U.S. and Europe. The primary objectives of the SOUP experiment are: to measure vector magnetic and velocity fields in the solar atmosphere with much better spatial resolution than can be achieved from the ground; to study the physical processes that store magnetic energy in active regions and the conditions that trigger its release; and to understand how magnetic flux emerges, evolves, combines, and disappears on spatial scales of 400 to 100,000 km. SOUP is designed to study intensity, magnetic, and velocity fields in the photosphere and low chromosphere with 0.5 arcsec resolution, free of atmospheric disturbances. The instrument includes: a 30 cm Cassegrain telescope; an active mirror for image stabilization; broadband film and TV cameras; a birefringent filter, tunable over 5100 to 6600 A with 0.05 A bandpass; a 35 mm film camera and a digital CCD camera behind the filter; and a high-speed digital image processor.
NASA Astrophysics Data System (ADS)
Tarbell, T.; Frank, Z.; Gilbreth, C.; Shine, R.; Title, A.; Topka, K.; Wolfson, J.
SOUP is a versatile, visible-light solar observatory, built for space or balloon flight. It is designed to study magnetic and velocity fields in the solar atmosphere with high spatial resolution and temporal uniformity, which cannot be achieved from the surface of the earth. The SOUP investigation is carried out by the Lockheed Palo Alto Research Laboratory, under contract to NASA's Marshall Space Flight Center. Co-investigators include staff members at a dozen observatories and universities in the U.S. and Europe. The primary objectives of the SOUP experiment are: to measure vector magnetic and velocity fields in the solar atmosphere with much better spatial resolution than can be achieved from the ground; to study the physical processes that store magnetic energy in active regions and the conditions that trigger its release; and to understand how magnetic flux emerges, evolves, combines, and disappears on spatial scales of 400 to 100,000 km. SOUP is designed to study intensity, magnetic, and velocity fields in the photosphere and low chromosphere with 0.5 arcsec resolution, free of atmospheric disturbances. The instrument includes: a 30 cm Cassegrain telescope; an active mirror for image stabilization; broadband film and TV cameras; a birefringent filter, tunable over 5100 to 6600 A with 0.05 A bandpass; a 35 mm film camera and a digital CCD camera behind the filter; and a high-speed digital image processor.
VizieR Online Data Catalog: The Chandra Source Catalog, Release 1.1 (Evans+ 2012)
NASA Astrophysics Data System (ADS)
Evans, I. N.; Primini, F. A.; Glotfelty, C. S.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Fabbiano, G.; Galle, E. C.; Gibbs, D. G.; Grier, J. D.; Hain, R. M.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Kashyap, V. L.; Lauer, J.; McCollough, M. L.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Mossman, A. E.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Rots, A. H.; Siemiginowska, A.; Sundheim, B. A.; Tibbetts, M. S.; van Stone, D. W.; Winkelman, S. L.; Zografou, P.
2014-01-01
This version of the catalog is release 1.1. It includes the information contained in release 1.0.1, plus point and compact source data extracted from HRC imaging observations, and catch-up ACIS observations released publicly prior to the end of 2009. (1 data file).
Pacific Health Research Guidelines: The Cartography of an Ethical Relationship
ERIC Educational Resources Information Center
Mila-Schaaf, Karlo
2009-01-01
In 2004 the Health Research Council of New Zealand (HRC) published a set of "Guidelines on Pacific health research". The Guidelines were an attempt to articulate the features of ethical research relationships with Pacific peoples living in Aotearoa New Zealand. This article describes the process of developing these guidelines, using…
Simultaneous Chandra/Swift Observations of the RT Cru Symbiotic System
NASA Astrophysics Data System (ADS)
Kashyap, Vinay; Kennea, J. A.; Karovska, M.; Calibration, Chandra
2013-04-01
The symbiotic star RT Cru was observed simultaneously by the Chandra/HRC-I and Swift/XRT in Dec 2012. The observations were carried out as part of a program to calibrate the Chandra PSF. The Chandra light curve shows a number of brightenings by factors of 2, with strong indications of a softening of the spectrum at these times. Swift observations cover a brief part of the Chandra light curve, and the intensities over this duration are tightly correlated. The Swift spectral data confirm the anticorrelation between intensity and spectral hardness. However, there are differences in the correlations at different periods that are not understood. We report on our analysis of the data, with emphasis on the spectral modeling at different times and intensity levels, and discuss the implications of the results on the emission mechanisms on symbiotic stars. We also report our inferences on the structure and energy dependence of the Chandra PSF anomaly, and on the high-energy cross-calibration between the HRC-I and XRT. This work is supported by the NASA contract NAS8-03060 to the Chandra X-ray Center.
Gazi, Anastasia D; Charova, Spyridoula; Aivaliotis, Michalis; Panopoulos, Nicholas J; Kokkinidis, Michael
2015-01-01
Bacterial type III secretion systems (T3SSs) are specialized multicomponent nanomachines that mediate the transport of proteins either to extracellular locations or directly into eukaryotic host cell cytoplasm. Erwinia amylovora, the main agent of rosaceous plants fireblight disease, employs an Hrp/Hrc1 T3SS to accomplish its pathogenesis. The regulatory network that controls the activation of this T3SS is largely unknown in E. amylovora. However, in Pseudomonas syringae pathovars, the HrpG/HrpV complex has been shown to directly regulate the activity of transcription factor HrpS and consequently the upregulation of the Hrp/Hrc1 T3SS related genes. In this work, we report the successful recombinant production and purification of a stable E. amylovora HrpG/HrpV complex, using pPROpET, a bicistronic expression vector. Furthermore, we present the first solution structure of this complex based on small-angle X-ray scattering data. © FEMS 2014. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Electroforming of optical tooling in high-strength Ni-Co alloy
NASA Astrophysics Data System (ADS)
Stein, Berl
2003-05-01
Plastic optics are often mass produced by injection, compression or injection-compression molding. Optical quality molds can be directly machined in appropriate materials (tool steels, electroless nickel, aluminum, etc.), but much greater cost efficiency can be achieved with electroformed modl inserts. Traditionally, electroforming of optical quality mold inserts has been carried out in nickel, a material much softer than tool steels which, when hardened to 45 - 50 HRc usually exhibit high wear resistance and long service life (hundreds of thousands of impressions per mold). Because of their low hardness (< 20 HRc), nickel molds can produce only tens of thousands of parts before they are scrapped due to wear or accidental damage. This drawback prevented their wider usage in general plastic and optical mold making. Recently, NiCoForm has developed a proprietary Ni-CO electroforming bath combining the high strength and wear resistance of the alloy with the low stress and high replication fidelity typical of pure nickel electroforming. This paper will outline the approach to electroforming of optical quality tooling in low stress, high strength Ni-Co alloy and present several examples of electroformed NiColoy mold inserts.
NASA Astrophysics Data System (ADS)
Hsieh, Chih-Chun; Liu, Yi-Chia; Wang, Jia-Siang; Wu, Weite
2014-07-01
The aim of this study is to discuss the effect of microstructural development with different Ti contents in Fe-based hardfacing alloys. A series of Fe-Cr-C-Si-Mn-xTi alloy fillers was deposited on SS400 low carbon steel substrate using oscillating gas tungsten arc welding. The microstructure in the Fe-based hardfacing alloy without Ti content addition included: the primary γ, eutectic γ+(Fe,Cr)3C, eutectic γ+(Fe,Cr)2C and martensite. With increasing Ti contents, the microstructures showed the primary TiC carbide, γ phase and eutectic γ+(Fe,Cr,Ti)3C. The amount and size of TiC carbide in the hardfacing layers increased as the Ti content increased. However, the eutectic γ+(Fe,Cr,Ti)3C content decreased as the Ti content increased. According to the results of the hardness test, the lowest hardness value (HRC 54.93) was found with 0% wt% Ti and the highest hardness (HRC 60.29) was observed with 4.87 wt% Ti.
NASA Technical Reports Server (NTRS)
Voellmer, George M.; Jackson, Michael L.; Shirron, Peter J.; Tuttle, James G.
2002-01-01
The High Resolution Airborne Wideband Camera (HAWC) and the Submillimeter And Far Infrared Experiment (SAFIRE) will use identical Adiabatic Demagnetization Refrigerators (ADR) to cool their detectors to 200mK and 100mK, respectively. In order to minimize thermal loads on the salt pill, a Kevlar suspension system is used to hold it in place. An innovative, kinematic suspension system is presented. The suspension system is unique in that it consists of two parts that can be assembled and tensioned offline, and later bolted onto the salt pill.
MacPhee, A. G.; Dymoke-Bradshaw, A. K. L.; Hares, J. D.; ...
2016-08-08
Here, we report simulationsand experiments that demonstrate an increasein spatial resolution ofthe NIF core diagnostic x-ray streak camerasby a factor of two, especially off axis. A designwas achieved by usinga corrector electron optic to flatten the field curvature at the detector planeand corroborated by measurement. In addition, particle in cell simulations were performed to identify theregions in the streak camera that contribute most to space charge blurring. Our simulations provide a tool for convolving syntheticpre-shot spectra with the instrument functionso signal levels can be set to maximize dynamic range for the relevant part of the streak record.
High-resolution continuum observations of the Sun
NASA Technical Reports Server (NTRS)
Zirin, Harold
1987-01-01
The aim of the PFI or photometric filtergraph instrument is to observe the Sun in the continuum with as high resolution as possible and utilizing the widest range of wavelengths. Because of financial and political problems the CCD was eliminated so that the highest photometric accuracy is only obtainable by comparison with the CFS images. Presently there is a limitation to wavelengths above 2200 A due to the lack of sensitivity of untreated film below 2200 A. Therefore the experiment at present consists of a film camera with 1000 feet of film and 12 filters. The PFI experiments are outlined using only two cameras. Some further problems of the experiment are addressed.
NASA Astrophysics Data System (ADS)
Kittle, David S.; Patil, Chirag G.; Mamelak, Adam; Hansen, Stacey; Perry, Jeff; Ishak, Laura; Black, Keith L.; Butte, Pramod V.
2016-03-01
Current surgical microscopes are limited in sensitivity for NIR fluorescence. Recent developments in tumor markers attached with NIR dyes require newer, more sensitive imaging systems with high resolution to guide surgical resection. We report on a small, single camera solution enabling advanced image processing opportunities previously unavailable for ultra-high sensitivity imaging of these agents. The system captures both visible reflectance and NIR fluorescence at 300 fps while displaying full HD resolution video at 60 fps. The camera head has been designed to easily mount onto the Zeiss Pentero microscope head for seamless integration into surgical procedures.
NASA Astrophysics Data System (ADS)
Furlong, Cosme; Yokum, Jeffrey S.; Pryputniewicz, Ryszard J.
2002-06-01
Sensitivity, accuracy, and precision characteristics in quantitative optical metrology techniques, and specifically in optoelectronic holography based on fiber optics and high-spatial and high-digital resolution cameras, are discussed in this paper. It is shown that sensitivity, accuracy, and precision dependent on both, the effective determination of optical phase and the effective characterization of the illumination-observation conditions. Sensitivity, accuracy, and precision are investigated with the aid of National Institute of Standards and Technology (NIST) traceable gages, demonstrating the applicability of quantitative optical metrology techniques to satisfy constantly increasing needs for the study and development of emerging technologies.
Design and performance of a large area neutron sensitive anger camera
Visscher, Theodore; Montcalm, Christopher A.; Donahue, Jr., Cornelius; ...
2015-05-21
We describe the design and performance of a 157mm x 157mm two dimensional neutron detector. The detector uses the Anger principle to determine the position of neutrons. We have verified FWHM resolution of < 1.2mm with distortion < 0.5mm on over 50 installed Anger Cameras. The performance of the detector is limited by the light yield of the scintillator, and it is estimated that the resolution of the current detector could be doubled with a brighter scintillator. Data collected from small (<1mm 3) single crystal reference samples at the single crystal instrument TOPAZ provide results with low R w(F) values
Detecting personnel around UGVs using stereo vision
NASA Astrophysics Data System (ADS)
Bajracharya, Max; Moghaddam, Baback; Howard, Andrew; Matthies, Larry H.
2008-04-01
Detecting people around unmanned ground vehicles (UGVs) to facilitate safe operation of UGVs is one of the highest priority issues in the development of perception technology for autonomous navigation. Research to date has not achieved the detection ranges or reliability needed in deployed systems to detect upright pedestrians in flat, relatively uncluttered terrain, let alone in more complex environments and with people in postures that are more difficult to detect. Range data is essential to solve this problem. Combining range data with high resolution imagery may enable higher performance than range data alone because image appearance can complement shape information in range data and because cameras may offer higher angular resolution than typical range sensors. This makes stereo vision a promising approach for several reasons: image resolution is high and will continue to increase, the physical size and power dissipation of the cameras and computers will continue to decrease, and stereo cameras provide range data and imagery that are automatically spatially and temporally registered. We describe a stereo vision-based pedestrian detection system, focusing on recent improvements to a shape-based classifier applied to the range data, and present frame-level performance results that show great promise for the overall approach.
NASA Technical Reports Server (NTRS)
Barnes, J. C. (Principal Investigator); Smallwood, M. D.; Cogan, J. L.
1975-01-01
The author has identified the following significant results. Of the four black and white S190A camera stations, snowcover is best defined in the two visible spectral bands, due in part to their better resolution. The overall extent of the snow can be mapped more precisely, and the snow within shadow areas is better defined in the visible bands. Of the two S190A color products, the aerial color photography is the better. Because of the contrast in color between snow and snow-free terrain and the better resolution, this product is concluded to be the best overall of the six camera stations for detecting and mapping snow. Overlapping frames permit stereo viewing, which aids in distinguishing clouds from the underlying snow. Because of the greater spatial resolution of the S190B earth terrain camera, areal snow extent can be mapped in greater detail than from the S190A photographs. The snow line elevation measured from the S190A and S190B photographs is reasonable compared to the meager ground truth data available.
2005-06-20
One of the two pictures of Tempel 1 (see also PIA02101) taken by Deep Impact's medium-resolution camera is shown next to data of the comet taken by the spacecraft's infrared spectrometer. This instrument breaks apart light like a prism to reveal the "fingerprints," or signatures, of chemicals. Even though the spacecraft was over 10 days away from the comet when these data were acquired, it detected some of the molecules making up the comet's gas and dust envelope, or coma. The signatures of these molecules -- including water, hydrocarbons, carbon dioxide and carbon monoxide -- can be seen in the graph, or spectrum. Deep Impact's impactor spacecraft is scheduled to collide with Tempel 1 at 10:52 p.m. Pacific time on July 3 (1:52 a.m. Eastern time, July 4). The mission's flyby spacecraft will use its infrared spectrometer to sample the ejected material, providing the first look at the chemical composition of a comet's nucleus. These data were acquired from June 20 to 21, 2005. The picture of Tempel 1 was taken by the flyby spacecraft's medium-resolution instrument camera. The infrared spectrometer uses the same telescope as the high-resolution instrument camera. http://photojournal.jpl.nasa.gov/catalog/PIA02100
Study on the Spatial Resolution of Single and Multiple Coincidences Compton Camera
NASA Astrophysics Data System (ADS)
Andreyev, Andriy; Sitek, Arkadiusz; Celler, Anna
2012-10-01
In this paper we study the image resolution that can be obtained from the Multiple Coincidences Compton Camera (MCCC). The principle of MCCC is based on a simultaneous acquisition of several gamma-rays emitted in cascade from a single nucleus. Contrary to a standard Compton camera, MCCC can theoretically provide the exact location of a radioactive source (based only on the identification of the intersection point of three cones created by a single decay), without complicated tomographic reconstruction. However, practical implementation of the MCCC approach encounters several problems, such as low detection sensitivities result in very low probability of coincident triple gamma-ray detection, which is necessary for the source localization. It is also important to evaluate how the detection uncertainties (finite energy and spatial resolution) influence identification of the intersection of three cones, thus the resulting image quality. In this study we investigate how the spatial resolution of the reconstructed images using the triple-cone reconstruction (TCR) approach compares to images reconstructed from the same data using standard iterative method based on single-cone. Results show, that FWHM for the point source reconstructed with TCR was 20-30% higher than the one obtained from the standard iterative reconstruction based on expectation maximization (EM) algorithm and conventional single-cone Compton imaging. Finite energy and spatial resolutions of the MCCC detectors lead to errors in conical surfaces definitions (“thick” conical surfaces) which only amplify in image reconstruction when intersection of three cones is being sought. Our investigations show that, in spite of being conceptually appealing, the identification of triple cone intersection constitutes yet another restriction of the multiple coincidence approach which limits the image resolution that can be obtained with MCCC and TCR algorithm.
Diving-flight aerodynamics of a peregrine falcon (Falco peregrinus).
Ponitz, Benjamin; Schmitz, Anke; Fischer, Dominik; Bleckmann, Horst; Brücker, Christoph
2014-01-01
This study investigates the aerodynamics of the falcon Falco peregrinus while diving. During a dive peregrines can reach velocities of more than 320 km h⁻¹. Unfortunately, in freely roaming falcons, these high velocities prohibit a precise determination of flight parameters such as velocity and acceleration as well as body shape and wing contour. Therefore, individual F. peregrinus were trained to dive in front of a vertical dam with a height of 60 m. The presence of a well-defined background allowed us to reconstruct the flight path and the body shape of the falcon during certain flight phases. Flight trajectories were obtained with a stereo high-speed camera system. In addition, body images of the falcon were taken from two perspectives with a high-resolution digital camera. The dam allowed us to match the high-resolution images obtained from the digital camera with the corresponding images taken with the high-speed cameras. Using these data we built a life-size model of F. peregrinus and used it to measure the drag and lift forces in a wind-tunnel. We compared these forces acting on the model with the data obtained from the 3-D flight path trajectory of the diving F. peregrinus. Visualizations of the flow in the wind-tunnel uncovered details of the flow structure around the falcon's body, which suggests local regions with separation of flow. High-resolution pictures of the diving peregrine indicate that feathers pop-up in the equivalent regions, where flow separation in the model falcon occurred.
Slight Blurring in Newer Image from Mars Orbiter
2018-02-09
These two frames were taken of the same place on Mars by the same orbiting camera before (left) and after some images from the camera began showing unexpected blur. The images are from the High Resolution Imaging Science Experiment (HiRISE) camera on NASA's Mars Reconnaissance Orbiter. They show a patch of ground about 500 feet or 150 meters wide in Gusev Crater. The one on the left, from HiRISE observation ESP_045173_1645, was taken March 16, 2016. The one on the right was taken Jan. 9, 2018. Gusev Crater, at 15 degrees south latitude and 176 degrees east longitude, is the landing site of NASA's Spirit Mars rover in 2004 and a candidate landing site for a rover to be launched in 2020. HiRISE images provide important information for evaluating potential landing sites. The smallest boulders with measurable diameters in the left image are about 3 feet (90 centimeters) wide. In the blurred image, the smallest measurable are about double that width. As of early 2018, most full-resolution images from HiRISE are not blurred, and the cause of the blur is still under investigation. Even before blurred images were first seen, in 2017, observations with HiRISE commonly used a technique that covers more ground area at half the resolution. This shows features smaller than can be distinguished with any other camera orbiting Mars, and little blurring has appeared in these images. https://photojournal.jpl.nasa.gov/catalog/PIA22215
Tracking subpixel targets in domestic environments
NASA Astrophysics Data System (ADS)
Govinda, V.; Ralph, J. F.; Spencer, J. W.; Goulermas, J. Y.; Smith, D. H.
2006-05-01
In recent years, closed circuit cameras have become a common feature of urban life. There are environments however where the movement of people needs to be monitored but high resolution imaging is not necessarily desirable: rooms where privacy is required and the occupants are not comfortable with the perceived intrusion. Examples might include domiciliary care environments, prisons and other secure facilities, and even large open plan offices. This paper discusses algorithms that allow activity within this type of sensitive environment to be monitored using data from low resolution cameras (ones where all objects of interest are sub-pixel and cannot be resolved) and other non-intrusive sensors. The algorithms are based on techniques originally developed for wide area reconnaissance and surveillance applications. Of particular importance is determining the minimum spatial resolution that is required to provide a specific level of coverage and reliability.
Thin-filament pyrometry with a digital still camera.
Maun, Jignesh D; Sunderland, Peter B; Urban, David L
2007-02-01
A novel thin-filament pyrometer is presented. It involves a consumer-grade color digital still camera with 6 megapixels and 12 bits per color plane. SiC fibers were used and scanning-electron microscopy found them to be uniform with diameters of 13.9 micro m. Measurements were performed in a methane-air coflowing laminar jet diffusion flame with a luminosity length of 72 mm. Calibration of the pyrometer was accomplished with B-type thermocouples. The pyrometry measurements yielded gas temperatures in the range of 1400-2200 K with an estimated uncertainty of +/-60 K, a relative temperature resolution of +/-0.215 K, a spatial resolution of 42 mum, and a temporal resolution of 0.66 ms. Fiber aging for 10 min had no effect on the results. Soot deposition was less problematic for the pyrometer than for the thermocouple.
Multi-pinhole collimator design for small-object imaging with SiliSPECT: a high-resolution SPECT
NASA Astrophysics Data System (ADS)
Shokouhi, S.; Metzler, S. D.; Wilson, D. W.; Peterson, T. E.
2009-01-01
We have designed a multi-pinhole collimator for a dual-headed, stationary SPECT system that incorporates high-resolution silicon double-sided strip detectors. The compact camera design of our system enables imaging at source-collimator distances between 20 and 30 mm. Our analytical calculations show that using knife-edge pinholes with small-opening angles or cylindrically shaped pinholes in a focused, multi-pinhole configuration in combination with this camera geometry can generate narrow sensitivity profiles across the field of view that can be useful for imaging small objects at high sensitivity and resolution. The current prototype system uses two collimators each containing 127 cylindrically shaped pinholes that are focused toward a target volume. Our goal is imaging objects such as a mouse brain, which could find potential applications in molecular imaging.
Integration of USB and firewire cameras in machine vision applications
NASA Astrophysics Data System (ADS)
Smith, Timothy E.; Britton, Douglas F.; Daley, Wayne D.; Carey, Richard
1999-08-01
Digital cameras have been around for many years, but a new breed of consumer market cameras is hitting the main stream. By using these devices, system designers and integrators will be well posited to take advantage of technological advances developed to support multimedia and imaging applications on the PC platform. Having these new cameras on the consumer market means lower cost, but it does not necessarily guarantee ease of integration. There are many issues that need to be accounted for like image quality, maintainable frame rates, image size and resolution, supported operating system, and ease of software integration. This paper will describe briefly a couple of the consumer digital standards, and then discuss some of the advantages and pitfalls of integrating both USB and Firewire cameras into computer/machine vision applications.
A comparison of select image-compression algorithms for an electronic still camera
NASA Technical Reports Server (NTRS)
Nerheim, Rosalee
1989-01-01
This effort is a study of image-compression algorithms for an electronic still camera. An electronic still camera can record and transmit high-quality images without the use of film, because images are stored digitally in computer memory. However, high-resolution images contain an enormous amount of information, and will strain the camera's data-storage system. Image compression will allow more images to be stored in the camera's memory. For the electronic still camera, a compression algorithm that produces a reconstructed image of high fidelity is most important. Efficiency of the algorithm is the second priority. High fidelity and efficiency are more important than a high compression ratio. Several algorithms were chosen for this study and judged on fidelity, efficiency and compression ratio. The transform method appears to be the best choice. At present, the method is compressing images to a ratio of 5.3:1 and producing high-fidelity reconstructed images.
Design and realization of an AEC&AGC system for the CCD aerial camera
NASA Astrophysics Data System (ADS)
Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun
2015-08-01
An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.
Study on a High Compression Processing for Video-on-Demand e-learning System
NASA Astrophysics Data System (ADS)
Nomura, Yoshihiko; Matsuda, Ryutaro; Sakamoto, Ryota; Sugiura, Tokuhiro; Matsui, Hirokazu; Kato, Norihiko
The authors proposed a high-quality and small-capacity lecture-video-file creating system for distance e-learning system. Examining the feature of the lecturing scene, the authors ingeniously employ two kinds of image-capturing equipment having complementary characteristics : one is a digital video camera with a low resolution and a high frame rate, and the other is a digital still camera with a high resolution and a very low frame rate. By managing the two kinds of image-capturing equipment, and by integrating them with image processing, we can produce course materials with the greatly reduced file capacity : the course materials satisfy the requirements both for the temporal resolution to see the lecturer's point-indicating actions and for the high spatial resolution to read the small written letters. As a result of a comparative experiment, the e-lecture using the proposed system was confirmed to be more effective than an ordinary lecture from the viewpoint of educational effect.
CIRCE: The Canarias InfraRed Camera Experiment for the Gran Telescopio Canarias
NASA Astrophysics Data System (ADS)
Eikenberry, Stephen S.; Charcos, Miguel; Edwards, Michelle L.; Garner, Alan; Lasso-Cabrera, Nestor; Stelter, Richard D.; Marin-Franch, Antonio; Raines, S. Nicholas; Ackley, Kendall; Bennett, John G.; Cenarro, Javier A.; Chinn, Brian; Donoso, H. Veronica; Frommeyer, Raymond; Hanna, Kevin; Herlevich, Michael D.; Julian, Jeff; Miller, Paola; Mullin, Scott; Murphey, Charles H.; Packham, Chris; Varosi, Frank; Vega, Claudia; Warner, Craig; Ramaprakash, A. N.; Burse, Mahesh; Punnadi, Sunjit; Chordia, Pravin; Gerarts, Andreas; Martín, Héctor De Paz; Calero, María Martín; Scarpa, Riccardo; Acosta, Sergio Fernandez; Sánchez, William Miguel Hernández; Siegel, Benjamin; Pérez, Francisco Francisco; Martín, Himar D. Viera; Losada, José A. Rodríguez; Nuñez, Agustín; Tejero, Álvaro; González, Carlos E. Martín; Rodríguez, César Cabrera; Sendra, Jordi Molgó; Rodriguez, J. Esteban; Cáceres, J. Israel Fernádez; García, Luis A. Rodríguez; Lopez, Manuel Huertas; Dominguez, Raul; Gaggstatter, Tim; Lavers, Antonio Cabrera; Geier, Stefan; Pessev, Peter; Sarajedini, Ata; Castro-Tirado, A. J.
The Canarias InfraRed Camera Experiment (CIRCE) is a near-infrared (1-2.5μm) imager, polarimeter and low-resolution spectrograph operating as a visitor instrument for the Gran Telescopio Canarias (GTC) 10.4-m telescope. It was designed and built largely by graduate students and postdocs, with help from the University of Florida (UF) astronomy engineering group, and is funded by the UF and the US National Science Foundation. CIRCE is intended to help fill the gap in near-infrared capabilities prior to the arrival of Especrografo Multiobjecto Infra-Rojo (EMIR) to the GTC and will also provide the following scientific capabilities to compliment EMIR after its arrival: high-resolution imaging, narrowband imaging, high-time-resolution photometry, imaging polarimetry, and low resolution spectroscopy. In this paper, we review the design, fabrication, integration, lab testing, and on-sky performance results for CIRCE. These include a novel approach to the opto-mechanical design, fabrication, and alignment.
Chloroethene Biodegradation Potential, ADOT/PF Peger Road Maintenance Facility, Fairbanks, Alaska
Bradley, Paul M.; Chapelle, Frances H.
2004-01-01
A series of 14C-radiotracer-based microcosm experiments were conducted to assess: 1) the extent, rate and products of microbial dechlorination of trichloroethene (TCE), cis-dichloroethene (cis-DCE) and vinyl chloride (VC) in sediments at the Peger Road site; 2) the effect of three electron donor amendments (molasses, shrimp and crab chitin, and 'Hydrogen Release Compound' (HRC)) on microbial degradation of TCE in three Peger Road sediments; and 3) the potential significance at the site of chloroethene biodegradation processes other than reductive dechlorination. In these experiments, TCE biodegradation yielded the reduced products, DCE and VC, and the oxidation product CO 2. Biodegradation of DCE and VC involved stoichiometric oxidation to CO 2. Both laboratory microcosm study and field redox assessment results indicated that the predominant terminal electron accepting process in Peger Road plume sediments under anoxic conditions was Mn/Fe-reduction. The rates of chloroethene biodegradation observed in Peger Road sediment microcosms under low temperature conditions (4?C) were within the range of those observed in sediments from temperate (20?C) aquifer systems. This result confirmed that biodegradation can be a significant mechanism for in situ contaminant remediation even in cold temperature aquifers. The fact that CO2 was the sole product of cis-DCE and VC biodegradation detected in Peger Road sediments indicated that a natural attenuation assessment based on reduced daughter product accumulation may significantly underestimate the potential for DCE and VC biodegradation at the Peger Road. Neither HRC nor molasses addition stimulated TCE reductive dechlorination. The fact that molasses and HRC amendment did stimulate Mn/Fe-reduction suggests that addition of these electron donors favored microbial Mn/Fe-reduction to the detriment of microbial TCE dechlorinating activity. In contrast, amendment of sediment microcosms with shrimp and crab chitin resulted in the establishment of mixed Mn/Fe-reducing, SO42--reducing and methanogenic conditions and enhanced TCE biodegradation in two of three Peger Road sediment treatments.
NASA Astrophysics Data System (ADS)
Zhao, Changchun; Zhou, Yefei; Xing, Xiaolei; Liu, Sha; Ren, Xuejun; Yang, Qingxiang
2018-05-01
The wear resistance of Fe-based composite coating is significantly related with the character of carbides and matrix, which could be strongly affected by C content in it. In this work, the Fe-based composite coatings with different C contents were prepared. The microstructure and phase structure of the coatings were analyzed by scanning electron microscope (SEM) equipped with an energy-dispersive spectroscopy (EDS) and X-ray diffractometer (XRD). The hardness and wear resistance of the coatings were determined. Then the hardness and brittleness of carbon poor niobium carbides were calculated by first principles calculation. The results show that, the phase structures of the coatings are mainly composed of NbC, γ phase (retained austenite) and α phase (martensite). With the increase of C content, the retained austenite appears and C content of martensite is increased. The hardness of the coatings are increased from HRC 22 to HRC 59. The distribution and morphology of NbC are changed with the increase of C content. The NbC precipitated in reticular grain boundary can be observed when C content is 0.4 wt.% C (C-1). NbC turn into granular and small rod morphology when C content increases to 0.8 wt.% C (C-2). The cracks and defects cannot been found on the surface of the coating when C content is 1.2 wt.% C(C-3), whose hardness is HRC 58 and wear loss is 0.27 g/N cm2 in 8 h. The flaky M7C3 carbide precipitates on the coating when C content is 1.4 wt.% C(C-4), which weaken the wear resistance of the matrix. Compared with the hardfacing coatings with different C contents, the C-3 coating processes higher hardness and wear resistance.
Performance measurement of commercial electronic still picture cameras
NASA Astrophysics Data System (ADS)
Hsu, Wei-Feng; Tseng, Shinn-Yih; Chiang, Hwang-Cheng; Cheng, Jui-His; Liu, Yuan-Te
1998-06-01
Commercial electronic still picture cameras need a low-cost, systematic method for evaluating the performance. In this paper, we present a measurement method to evaluating the dynamic range and sensitivity by constructing the opto- electronic conversion function (OECF), the fixed pattern noise by the peak S/N ratio (PSNR) and the image shading function (ISF), and the spatial resolution by the modulation transfer function (MTF). The evaluation results of individual color components and the luminance signal from a PC camera using SONY interlaced CCD array as the image sensor are then presented.
Manned observations technology development, FY 1992 report
NASA Technical Reports Server (NTRS)
Israel, Steven
1992-01-01
This project evaluated the suitability of the NASA/JSC developed electronic still camera (ESC) digital image data for Earth observations from the Space Shuttle, as a first step to aid planning for Space Station Freedom. Specifically, image resolution achieved from the Space Shuttle using the current ESC system, which is configured with a Loral 15 mm x 15 mm (1024 x 1024 pixel array) CCD chip on the focal plane of a Nikon F4 camera, was compared to that of current handheld 70 mm Hasselblad 500 EL/M film cameras.
Imaging experiment: The Viking Lander
Mutch, T.A.; Binder, A.B.; Huck, F.O.; Levinthal, E.C.; Morris, E.C.; Sagan, C.; Young, A.T.
1972-01-01
The Viking Lander Imaging System will consist of two identical facsimile cameras. Each camera has a high-resolution mode with an instantaneous field of view of 0.04??, and survey and color modes with instantaneous fields of view of 0.12??. Cameras are positioned one meter apart to provide stereoscopic coverage of the near-field. The Imaging Experiment will provide important information about the morphology, composition, and origin of the Martian surface and atmospheric features. In addition, lander pictures will provide supporting information for other experiments in biology, organic chemistry, meteorology, and physical properties. ?? 1972.
Video Capture of Plastic Surgery Procedures Using the GoPro HERO 3+
Graves, Steven Nicholas; Shenaq, Deana Saleh; Langerman, Alexander J.
2015-01-01
Background: Significant improvements can be made in recoding surgical procedures, particularly in capturing high-quality video recordings from the surgeons’ point of view. This study examined the utility of the GoPro HERO 3+ Black Edition camera for high-definition, point-of-view recordings of plastic and reconstructive surgery. Methods: The GoPro HERO 3+ Black Edition camera was head-mounted on the surgeon and oriented to the surgeon’s perspective using the GoPro App. The camera was used to record 4 cases: 2 fat graft procedures and 2 breast reconstructions. During cases 1-3, an assistant remotely controlled the GoPro via the GoPro App. For case 4 the GoPro was linked to a WiFi remote, and controlled by the surgeon. Results: Camera settings for case 1 were as follows: 1080p video resolution; 48 fps; Protune mode on; wide field of view; 16:9 aspect ratio. The lighting contrast due to the overhead lights resulted in limited washout of the video image. Camera settings were adjusted for cases 2-4 to a narrow field of view, which enabled the camera’s automatic white balance to better compensate for bright lights focused on the surgical field. Cases 2-4 captured video sufficient for teaching or presentation purposes. Conclusions: The GoPro HERO 3+ Black Edition camera enables high-quality, cost-effective video recording of plastic and reconstructive surgery procedures. When set to a narrow field of view and automatic white balance, the camera is able to sufficiently compensate for the contrasting light environment of the operating room and capture high-resolution, detailed video. PMID:25750851
Re-scan confocal microscopy: scanning twice for better resolution.
De Luca, Giulia M R; Breedijk, Ronald M P; Brandt, Rick A J; Zeelenberg, Christiaan H C; de Jong, Babette E; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A; Stallinga, Sjoerd; Manders, Erik M M
2013-01-01
We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required.
Measuring the performance of super-resolution reconstruction algorithms
NASA Astrophysics Data System (ADS)
Dijk, Judith; Schutte, Klamer; van Eekeren, Adam W. M.; Bijl, Piet
2012-06-01
For many military operations situational awareness is of great importance. This situational awareness and related tasks such as Target Acquisition can be acquired using cameras, of which the resolution is an important characteristic. Super resolution reconstruction algorithms can be used to improve the effective sensor resolution. In order to judge these algorithms and the conditions under which they operate best, performance evaluation methods are necessary. This evaluation, however, is not straightforward for several reasons. First of all, frequency-based evaluation techniques alone will not provide a correct answer, due to the fact that they are unable to discriminate between structure-related and noise-related effects. Secondly, most super-resolution packages perform additional image enhancement techniques such as noise reduction and edge enhancement. As these algorithms improve the results they cannot be evaluated separately. Thirdly, a single high-resolution ground truth is rarely available. Therefore, evaluation of the differences in high resolution between the estimated high resolution image and its ground truth is not that straightforward. Fourth, different artifacts can occur due to super-resolution reconstruction, which are not known on forehand and hence are difficult to evaluate. In this paper we present a set of new evaluation techniques to assess super-resolution reconstruction algorithms. Some of these evaluation techniques are derived from processing on dedicated (synthetic) imagery. Other evaluation techniques can be evaluated on both synthetic and natural images (real camera data). The result is a balanced set of evaluation algorithms that can be used to assess the performance of super-resolution reconstruction algorithms.
Multi-Angle Snowflake Camera Instrument Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuefer, Martin; Bailey, J.
2016-07-01
The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASCmore » cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.« less
Kirk, R.L.; Howington-Kraus, E.; Redding, B.; Galuszka, D.; Hare, T.M.; Archinal, B.A.; Soderblom, L.A.; Barrett, J.M.
2003-01-01
We analyzed narrow-angle Mars Orbiter Camera (MOC-NA) images to produce high-resolution digital elevation models (DEMs) in order to provide topographic and slope information needed to assess the safety of candidate landing sites for the Mars Exploration Rovers (MER) and to assess the accuracy of our results by a variety of tests. The mapping techniques developed also support geoscientific studies and can be used with all present and planned Mars-orbiting scanner cameras. Photogrammetric analysis of MOC stereopairs yields DEMs with 3-pixel (typically 10 m) horizontal resolution, vertical precision consistent with ???0.22 pixel matching errors (typically a few meters), and slope errors of 1-3??. These DEMs are controlled to the Mars Orbiter Laser Altimeter (MOLA) global data set and consistent with it at the limits of resolution. Photoclinometry yields DEMs with single-pixel (typically ???3 m) horizontal resolution and submeter vertical precision. Where the surface albedo is uniform, the dominant error is 10-20% relative uncertainty in the amplitude of topography and slopes after "calibrating" photoclinometry against a stereo DEM to account for the influence of atmospheric haze. We mapped portions of seven candidate MER sites and the Mars Pathfinder site. Safety of the final four sites (Elysium, Gusev, Isidis, and Meridiani) was assessed by mission engineers by simulating landings on our DEMs of "hazard units" mapped in the sites, with results weighted by the probability of landing on those units; summary slope statistics show that most hazard units are smooth, with only small areas of etched terrain in Gusev crater posing a slope hazard.
Monitoring the spatial and temporal evolution of slope instability with Digital Image Correlation
NASA Astrophysics Data System (ADS)
Manconi, Andrea; Glueer, Franziska; Loew, Simon
2017-04-01
The identification and monitoring of ground deformation is important for an appropriate analysis and interpretation of unstable slopes. Displacements are usually monitored with in-situ techniques (e.g., extensometers, inclinometers, geodetic leveling, tachymeters and D-GPS), and/or active remote sensing methods (e.g., LiDAR and radar interferometry). In particular situations, however, the choice of the appropriate monitoring system is constrained by site-specific conditions. Slope areas can be very remote and/or affected by rapid surface changes, thus hardly accessible, often unsafe, for field installations. In many cases the use of remote sensing approaches might be also hindered because of unsuitable acquisition geometries, poor spatial resolution and revisit times, and/or high costs. The increasing availability of digital imagery acquired from terrestrial photo and video cameras allows us nowadays for an additional source of data. The latter can be exploited to visually identify changes of the scene occurring over time, but also to quantify the evolution of surface displacements. Image processing analyses, such as Digital Image Correlation (known also as pixel-offset or feature-tracking), have demonstrated to provide a suitable alternative to detect and monitor surface deformation at high spatial and temporal resolutions. However, a number of intrinsic limitations have to be considered when dealing with optical imagery acquisition and processing, including the effects of light conditions, shadowing, and/or meteorological variables. Here we propose an algorithm to automatically select and process images acquired from time-lapse cameras. We aim at maximizing the results obtainable from large datasets of digital images acquired with different light and meteorological conditions, and at retrieving accurate information on the evolution of surface deformation. We show a successful example of application of our approach in the Swiss Alps, more specifically in the Great Aletsch area, where slope instability was recently reactivated due to the progressive glacier retreat. At this location, time-lapse cameras have been installed during the last two years, ranging from low-cost and low-resolution webcams to more expensive high-resolution reflex cameras. Our results confirm that time-lapse cameras provide quantitative and accurate measurements of surface deformation evolution over space and time, especially in situations when other monitoring instruments fail.
Objective evaluation of slanted edge charts
NASA Astrophysics Data System (ADS)
Hornung, Harvey (.
2015-01-01
Camera objective characterization methodologies are widely used in the digital camera industry. Most objective characterization systems rely on a chart with specific patterns, a software algorithm measures a degradation or difference between the captured image and the chart itself. The Spatial Frequency Response (SFR) method, which is part of the ISO 122331 standard, is now very commonly used in the imaging industry, it is a very convenient way to measure a camera Modulation transfer function (MTF). The SFR algorithm can measure frequencies beyond the Nyquist frequency thanks to super-resolution, so it does provide useful information on aliasing and can provide modulation for frequencies between half Nyquist and Nyquist on all color channels of a color sensor with a Bayer pattern. The measurement process relies on a chart that is simple to manufacture: a straight transition from a bright reflectance to a dark one (black and white for instance), while a sine chart requires handling precisely shades of gray which can also create all sort of issues with printers that rely on half-toning. However, no technology can create a perfect edge, so it is important to assess the quality of the chart and understand how it affects the accuracy of the measurement. In this article, I describe a protocol to characterize the MTF of a slanted edge chart, using a high-resolution flatbed scanner. The main idea is to use the RAW output of the scanner as a high-resolution micro-densitometer, since the signal is linear it is suitable to measure the chart MTF using the SFR algorithm. The scanner needs to be calibrated in sharpness: the scanner MTF is measured with a calibrated sine chart and inverted to compensate for the modulation loss from the scanner. Then the true chart MTF is computed. This article compares measured MTF from commercial charts and charts printed on printers, and also compares how of the contrast of the edge (using different shades of gray) can affect the chart MTF, then concludes on what distance range and camera resolution the chart can reliably measure the camera MTF.
An image compression algorithm for a high-resolution digital still camera
NASA Technical Reports Server (NTRS)
Nerheim, Rosalee
1989-01-01
The Electronic Still Camera (ESC) project will provide for the capture and transmission of high-quality images without the use of film. The image quality will be superior to video and will approach the quality of 35mm film. The camera, which will have the same general shape and handling as a 35mm camera, will be able to send images to earth in near real-time. Images will be stored in computer memory (RAM) in removable cartridges readable by a computer. To save storage space, the image will be compressed and reconstructed at the time of viewing. Both lossless and loss-y image compression algorithms are studied, described, and compared.
Hubble Space Telescope photographed by Electronic Still Camera
1993-12-04
S61-E-008 (4 Dec 1993) --- This view of the Earth-orbiting Hubble Space Telescope (HST) was photographed with an Electronic Still Camera (ESC), and down linked to ground controllers soon afterward. This view was taken during rendezvous operations. Endeavour's crew captured the HST on December 4, 1993 in order to service the telescope. Over a period of five days, four of the crew members will work in alternating pairs outside Endeavour's shirt sleeve environment. Electronic still photography is a relatively new technology which provides the means for a handheld camera to electronically capture and digitize an image with resolution approaching film quality. The electronic still camera has flown as an experiment on several other shuttle missions.
Electronic Still Camera image of Astronaut Claude Nicollier working with RMS
1993-12-05
S61-E-006 (5 Dec 1993) --- The robot arm controlling work of Swiss scientist Claude Nicollier was photographed with an Electronic Still Camera (ESC), and down linked to ground controllers soon afterward. With the mission specialist's assistance, Endeavour's crew captured the Hubble Space Telescope (HST) on December 4, 1993. Four of the seven crew members will work in alternating pairs outside Endeavour's shirt sleeve environment to service the giant telescope. Electronic still photography is a relatively new technology which provides the means for a handheld camera to electronically capture and digitize an image with resolution approaching film quality. The electronic still camera has flown as an experiment on several other shuttle missions.
Deep Near-Infrared Surveys and Young Brown Dwarf Populations in Star-Forming Regions
NASA Astrophysics Data System (ADS)
Tamura, M.; Naoi, T.; Oasa, Y.; Nakajima, Y.; Nagashima, C.; Nagayama, T.; Baba, D.; Nagata, T.; Sato, S.; Kato, D.; Kurita, M.; Sugitani, K.; Itoh, Y.; Nakaya, H.; Pickles, A.
2003-06-01
We are currently conducting three kinds of IR surveys of star forming regions (SFRs) in order to seek for very low-mass young stellar populations. First is a deep JHKs-bands (simultaneous) survey with the SIRIUS camera on the IRSF 1.4m or the UH 2.2m telescopes. Second is a very deep JHKs survey with the CISCO IR camera on the Subaru 8.2m telescope. Third is a high resolution companion search around nearby YSOs with the CIAO adaptive optics coronagraph IR camera on the Subaru. In this contribution, we describe our SIRIUS camera and present preliminary results of the ongoing surveys with this new instrument.
Exploring the Universe with the Hubble Space Telescope
NASA Technical Reports Server (NTRS)
1990-01-01
A general overview is given of the operations, engineering challenges, and components of the Hubble Space Telescope. Deployment, checkout and servicing in space are discussed. The optical telescope assembly, focal plane scientific instruments, wide field/planetary camera, faint object spectrograph, faint object camera, Goddard high resolution spectrograph, high speed photometer, fine guidance sensors, second generation technology, and support systems and services are reviewed.
Procurement specification color graphic camera system
NASA Technical Reports Server (NTRS)
Prow, G. E.
1980-01-01
The performance and design requirements for a Color Graphic Camera System are presented. The system is a functional part of the Earth Observation Department Laboratory System (EODLS) and will be interfaced with Image Analysis Stations. It will convert the output of a raster scan computer color terminal into permanent, high resolution photographic prints and transparencies. Images usually displayed will be remotely sensed LANDSAT imager scenes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conder, A.; Mummolo, F. J.
The goal of the project was to develop a compact, large active area, high spatial resolution, high dynamic range, charge-coupled device (CCD) camera to replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating X-rays. The camera head and controller needed to be capable of operation within a vacuum environment and small enough to be fielded within the small vacuum target chambers at LLNL.