NASA Astrophysics Data System (ADS)
Arndt, Jan Erik; Schenke, Hans Werner; Jakobsson, Martin; Nitsche, Frank O.; Buys, Gwen; Goleby, Bruce; Rebesco, Michele; Bohoyo, Fernando; Hong, Jongkuk; Black, Jenny; Greku, Rudolf; Udintsev, Gleb; Barrios, Felipe; Reynoso-Peralta, Walter; Taisei, Morishita; Wigley, Rochelle
2013-06-01
International Bathymetric Chart of the Southern Ocean (IBCSO) Version 1.0 is a new digital bathymetric model (DBM) portraying the seafloor of the circum-Antarctic waters south of 60°S. IBCSO is a regional mapping project of the General Bathymetric Chart of the Oceans (GEBCO). The IBCSO Version 1.0 DBM has been compiled from all available bathymetric data collectively gathered by more than 30 institutions from 15 countries. These data include multibeam and single-beam echo soundings, digitized depths from nautical charts, regional bathymetric gridded compilations, and predicted bathymetry. Specific gridding techniques were applied to compile the DBM from the bathymetric data of different origin, spatial distribution, resolution, and quality. The IBCSO Version 1.0 DBM has a resolution of 500 × 500 m, based on a polar stereographic projection, and is publicly available together with a digital chart for printing from the project website (www.ibcso.org) and at
Assessment of Reference Height Models on Quality of Tandem-X dem
NASA Astrophysics Data System (ADS)
Mirzaee, S.; Motagh, M.; Arefi, H.
2015-12-01
The aim of this study is to investigate the effect of various Global Digital Elevation Models (GDEMs) in producing high-resolution topography model using TanDEM-X (TDX) Coregistered Single Look Slant Range Complex (CoSSC) images. We selected an image acquired on Jun 12th, 2012 over Doroud region in Lorestan, west of Iran and used 4 external digital elevation models in our processing including DLR/ASI X-SAR DEM (SRTM-X, 30m resolution), ASTER GDEM Version 2 (ASTER-GDEMV2, 30m resolution), NASA SRTM Version 4 (SRTM-V4, 90m resolution), and a local photogrammetry-based DEM prepared by National Cartographic Center (NCC DEM, 10m resolution) of Iran. InSAR procedure for DEM generation was repeated four times with each of the four external height references. The quality of each external DEM was initially assessed using ICESat filtered points. Then, the quality of, each TDX-based DEM was assessed using the more precise external DEM selected in the previous step. Results showed that both local (NCC) DEM and SRTM X-band performed the best (RMSE< 9m) for TDX-DEM generation. In contrast, ASTER GDEM v2 and SRTM C-band v4 showed poorer quality.
Detection of proximal caries using digital radiographic systems with different resolutions.
Nikneshan, Sima; Abbas, Fatemeh Mashhadi; Sabbagh, Sedigheh
2015-01-01
Dental radiography is an important tool for detection of caries and digital radiography is the latest advancement in this regard. Spatial resolution is a characteristic of digital receptors used for describing the quality of images. This study was aimed to compare the diagnostic accuracy of two digital radiographic systems with three different resolutions for detection of noncavitated proximal caries. Diagnostic accuracy. Seventy premolar teeth were mounted in 14 gypsum blocks. Digora; Optime and RVG Access were used for obtaining digital radiographs. Six observers evaluated the proximal surfaces in radiographs for each resolution in order to determine the depth of caries based on a 4-point scale. The teeth were then histologically sectioned, and the results of histologic analysis were considered as the gold standard. Data were entered using SPSS version 18 software and the Kruskal-Wallis test was used for data analysis. P <0.05 was considered as statistically significant. No significant difference was found between different resolutions for detection of proximal caries (P > 0.05). RVG access system had the highest specificity (87.7%) and Digora; Optime at high resolution had the lowest specificity (84.2%). Furthermore, Digora; Optime had higher sensitivity for detection of caries exceeding outer half of enamel. Judgment of oral radiologists for detection of the depth of caries had higher reliability than that of restorative dentistry specialists. The three resolutions of Digora; Optime and RVG access had similar accuracy in detection of noncavitated proximal caries.
Schmidt, M; Werther, B; Fuerstenau, N; Matthias, M; Melz, T
2001-04-09
A fiber-optic extrinsic Fabry-Perot interferometer strain sensor (EFPI-S) of ls = 2.5 cm sensor length using three-wavelength digital phase demodulation is demonstrated to exhibit <50 pm displacement resolution (<2nm/m strain resolution) when measuring the cross expansion of a PZT-ceramic plate. The sensing (single-mode downlead-) and reflecting fibers are fused into a 150/360 microm capillary fiber where the fusion points define the sensor length. Readout is performed using an improved version of the previously described three-wavelength digital phase demodulation method employing an arctan-phase stepping algorithm. In the resent experiments the strain sensitivity was varied via the mapping of the arctan - lookup table to the 16-Bit DA-converter range from 188.25 k /V (6 Volt range 1130 k ) to 11.7 k /Volt (range 70 k ).
Digital Camera Control for Faster Inspection
NASA Technical Reports Server (NTRS)
Brown, Katharine; Siekierski, James D.; Mangieri, Mark L.; Dekome, Kent; Cobarruvias, John; Piplani, Perry J.; Busa, Joel
2009-01-01
Digital Camera Control Software (DCCS) is a computer program for controlling a boom and a boom-mounted camera used to inspect the external surface of a space shuttle in orbit around the Earth. Running in a laptop computer in the space-shuttle crew cabin, DCCS commands integrated displays and controls. By means of a simple one-button command, a crewmember can view low- resolution images to quickly spot problem areas and can then cause a rapid transition to high- resolution images. The crewmember can command that camera settings apply to a specific small area of interest within the field of view of the camera so as to maximize image quality within that area. DCCS also provides critical high-resolution images to a ground screening team, which analyzes the images to assess damage (if any); in so doing, DCCS enables the team to clear initially suspect areas more quickly than would otherwise be possible and further saves time by minimizing the probability of re-imaging of areas already inspected. On the basis of experience with a previous version (2.0) of the software, the present version (3.0) incorporates a number of advanced imaging features that optimize crewmember capability and efficiency.
Timing Characterization of Helium-4 Fast Neutron Detector with EJ-309 Organic Liquid Scintillator
NASA Astrophysics Data System (ADS)
Liang, Yinong; Zhu, Ting; Enqvist, Andreas
2018-01-01
Recently, the Helium-4 gas fast neutron scintillation detectors is being used in time-sensitive measurements, such time-of-flight and multiplicity counting. In this paper, a set of time aligned signals was acquired in a coincidence measurement using the Helium-4 gas detectors and EJ-309 liquid scintillators. The high-speed digitizer system is implanted with a trigger moving average window (MAW) unit combing with its constant fraction discriminator (CFD) feature. It can calculate a "time offset" to the timestamp value to get a higher resolution timestamp (up to 50 ps), which is better than the digitizer's time resolution (4 ns) [1]. The digitized waveforms were saved to the computer hard drive and post processed with digital analysis code to determine the difference of their arrival times. The full-width at half-maximum (FWHM) of the Gaussian fit was used as to examine the resolution. For the cascade decay of Cobalt-60 (1.17 and 1.33 MeV), the first version of the Helium-4 detector with two Hamamatsu R580 photomultipliers (PMT) installed at either end of the cylindrical gas chamber (20 cm in length and 4.4 cm in diameter) has a time resolution which is about 3.139 ns FWHM. With improved knowledge of the timing performance, the Helium-4 scintillation detectors are excellent for neutron energy spectrometry applications requiring high temporal and energy resolutions.
Image transfer protocol in progressively increasing resolution
NASA Technical Reports Server (NTRS)
Percival, Jeffrey W. (Inventor); White, Richard L. (Inventor)
1999-01-01
A method of transferring digital image data over a communication link transforms and orders the data so that, as data is received by a receiving station, a low detail version of the image is immediately generated with later transmissions of data providing progressively greater detail in this image. User instructions are accepted, limiting the ultimate resolution of the image or suspending enhancement of the image except in certain user defined regions. When a low detail image is requested followed by a request for a high detailed version of the same image, the originally transmitted data of the low resolution image is not discarded or retransmitted but used with later data to improve the originally transmitted image. Only a single copy of the transformed image need be retained by the transmitting device in order to satisfy requests for different amounts of image detail.
NASCAP simulation of PIX 2 experiments
NASA Technical Reports Server (NTRS)
Roche, J. C.; Mandell, M. J.
1985-01-01
The latest version of the NASCAP/LEO digital computer code used to simulate the PIX 2 experiment is discussed. NASCAP is a finite-element code and previous versions were restricted to a single fixed mesh size. As a consequence the resolution was dictated by the largest physical dimension to be modeled. The latest version of NASCAP/LEO can subdivide selected regions. This permitted the modeling of the overall Delta launch vehicle in the primary computational grid at a coarse resolution, with subdivided regions at finer resolution being used to pick up the details of the experiment module configuration. Langmuir probe data from the flight were used to estimate the space plasma density and temperature and the Delta ground potential relative to the space plasma. This information is needed for input to NASCAP. Because of the uncertainty or variability in the values of these parameters, it was necessary to explore a range around the nominal value in order to determine the variation in current collection. The flight data from PIX 2 were also compared with the results of the NASCAP simulation.
Threshold matrix for digital halftoning by genetic algorithm optimization
NASA Astrophysics Data System (ADS)
Alander, Jarmo T.; Mantere, Timo J.; Pyylampi, Tero
1998-10-01
Digital halftoning is used both in low and high resolution high quality printing technologies. Our method is designed to be mainly used for low resolution ink jet marking machines to produce both gray tone and color images. The main problem with digital halftoning is pink noise caused by the human eye's visual transfer function. To compensate for this the random dot patterns used are optimized to contain more blue than pink noise. Several such dot pattern generator threshold matrices have been created automatically by using genetic algorithm optimization, a non-deterministic global optimization method imitating natural evolution and genetics. A hybrid of genetic algorithm with a search method based on local backtracking was developed together with several fitness functions evaluating dot patterns for rectangular grids. By modifying the fitness function, a family of dot generators results, each with its particular statistical features. Several versions of genetic algorithms, backtracking and fitness functions were tested to find a reasonable combination. The generated threshold matrices have been tested by simulating a set of test images using the Khoros image processing system. Even though the work was focused on developing low resolution marking technology, the resulting family of dot generators can be applied also in other halftoning application areas including high resolution printing technology.
Global 30m Height Above the Nearest Drainage
NASA Astrophysics Data System (ADS)
Donchyts, Gennadii; Winsemius, Hessel; Schellekens, Jaap; Erickson, Tyler; Gao, Hongkai; Savenije, Hubert; van de Giesen, Nick
2016-04-01
Variability of the Earth surface is the primary characteristics affecting the flow of surface and subsurface water. Digital elevation models, usually represented as height maps above some well-defined vertical datum, are used a lot to compute hydrologic parameters such as local flow directions, drainage area, drainage network pattern, and many others. Usually, it requires a significant effort to derive these parameters at a global scale. One hydrological characteristic introduced in the last decade is Height Above the Nearest Drainage (HAND): a digital elevation model normalized using nearest drainage. This parameter has been shown to be useful for many hydrological and more general purpose applications, such as landscape hazard mapping, landform classification, remote sensing and rainfall-runoff modeling. One of the essential characteristics of HAND is its ability to capture heterogeneities in local environments, difficult to measure or model otherwise. While many applications of HAND were published in the academic literature, no studies analyze its variability on a global scale, especially, using higher resolution DEMs, such as the new, one arc-second (approximately 30m) resolution version of SRTM. In this work, we will present the first global version of HAND computed using a mosaic of two DEMS: 30m SRTM and Viewfinderpanorama DEM (90m). The lower resolution DEM was used to cover latitudes above 60 degrees north and below 56 degrees south where SRTM is not available. We compute HAND using the unmodified version of the input DEMs to ensure consistency with the original elevation model. We have parallelized processing by generating a homogenized, equal-area version of HydroBASINS catchments. The resulting catchment boundaries were used to perform processing using 30m resolution DEM. To compute HAND, a new version of D8 local drainage directions as well as flow accumulation were calculated. The latter was used to estimate river head by incorporating fixed and variable thresholding methods. The resulting HAND dataset was analyzed regarding its spatial variability and to assess the global distribution of the main landform types: valley, ecotone, slope, and plateau. The method used to compute HAND was implemented using PCRaster software, running on Google Compute Engine platform running under Ubuntu Linux. The Google Earth Engine was used to perform mosaicing and clipping of the original DEMs as well as to provide access to the final product. The effort took about three months of computing time on eight core CPU virtual machine.
Geologic Map of the Point Lay Quadrangle, Alaska
Mull, Charles G.; Houseknecht, David W.; Pessel, G.H.; Garrity, Christopher P.
2008-01-01
This map is a product of the USGS Digital Geologic Maps of Northern Alaska project, which captures in digital format quadrangles across the entire width of northern Alaska. Sources include geologic maps previously published in hardcopy format and recent updates and revisions based on field mapping by the Alaska Department of Natural Resources, Division of Geological and Geophysical Surveys and Division of Oil and Gas, and the U.S. Geological Survey. Individual quadrangles are digitized at either 1:125,000 or 1:250,000 depending on the resolution of source maps. The project objective is to produce a set of digital geologic maps with uniform stratigraphic nomenclature and structural annotation, and publish those maps electronically. The paper version of this map is available for purchase from the USGS Store.
Geologic Map of the Ikpikpuk River Quadrangle, Alaska
Mull, Charles G.; Houseknecht, David W.; Pessel, G.H.; Garrity, Christopher P.
2005-01-01
This map is a product of the USGS Digital Geologic Maps of Northern Alaska project, which captures in digital format quadrangles across the entire width of northern Alaska. Sources include geologic maps previously published in hardcopy format and recent updates and revisions based on field mapping by the Alaska Department of Natural Resources, Division of Geological and Geophysical Surveys and Division of Oil and Gas, and the U.S. Geological Survey. Individual quadrangles are digitized at either 1:125,000 or 1:250,000 depending on the resolution of source maps. The project objective is to produce a set of digital geologic maps with uniform stratigraphic nomenclature and structural annotation, and publish those maps electronically. The paper version of this map is available for purchase from the USGS Store.
Geologic Map of the Lookout Ridge Quadrangle, Alaska
Mull, Charles G.; Houseknecht, David W.; Pessel, G.H.; Garrity, Christopher P.
2006-01-01
This map is a product of the USGS Digital Geologic Maps of Northern Alaska project, which captures in digital format quadrangles across the entire width of northern Alaska. Sources include geologic maps previously published in hardcopy format and recent updates and revisions based on field mapping by the Alaska Department of Natural Resources, Division of Geological and Geophysical Surveys and Division of Oil and Gas, and the U.S. Geological Survey. Individual quadrangles are digitized at either 1:125,000 or 1:250,000 depending on the resolution of source maps. The project objective is to produce a set of digital geologic maps with uniform stratigraphic nomenclature and structural annotation, and publish those maps electronically. The paper version of this map is available for purchase from the USGS Store.
Ultrasonic Ranging System With Increased Resolution
NASA Technical Reports Server (NTRS)
Meyer, William E.; Johnson, William G.
1987-01-01
Master-oscillator frequency increased. Ultrasonic range-measuring system with 0.1-in. resolution provides continuous digital display of four distance readings, each updated four times per second. Four rangefinder modules in system are modified versions of rangefinder used for automatic focusing in commercial series of cameras. Ultrasonic pulses emitted by system innocuous to both people and equipment. Provides economical solutions to such distance-measurement problems as posed by boats approaching docks, truck backing toward loading platform, runway-clearance readout for tail of airplane with high angle attack, or burglar alarm.
Release of the World Digital Magnetic Anomaly Map version 2 (WDMAM v2) scheduled
NASA Astrophysics Data System (ADS)
Dyment, Jérôme; Lesur, Vincent; Choi, Yujin; Hamoudi, Mohamed; Thébault, Erwan; Catalan, Manuel
2015-04-01
The World Digital Magnetic Anomaly Map is an international initiative carried out under the auspices of the International Association of Geomagnetism and Aeronomy (IAGA) and the Commission for the Geological Map of the World (CGMW). A first version of the map has been published and distributed eight years ago (WDMAM v1; Korhonen et al., 2007). After a call for an improved second version of the map in 2011, the slow process of data compilation, map preparation, evaluation and finalization is near completion, and the WDMAM v2 will be released at the International Union of Geophysics and Geodesy (IUGG) meeting to be held in Prag in June-July 2015. In this presentation we display several shortcomings of the WDMAM v1, both on continental and oceanic areas, that are hopefully alleviated in the WDMAM v2, and discuss the process leading to the new map. We reiterate a long-standing call for aeromagnetic and marine magnetic data contribution, and explore future directions to pursue the effort toward a more complete, higher resolution magnetic anomaly map of the World.
Mars Digital Image Model 2.1 Control Network
NASA Technical Reports Server (NTRS)
Archinal, B. A.; Kirk, R. L.; Duxbury, T. C.; Lee, E. M.; Sucharski, R.; Cook, D.
2003-01-01
USGS is currently preparing a new version of its global Mars digital image mosaic, which will be known as MDIM 2.1. As part of this process we are completing a new photogrammetric solution of the global Mars control network. This is an improved version of the network established earlier by RAND and USGS personnel, as partially described previously. MDIM 2.1 will have many improvements over earlier Viking Orbiter (VO) global mosaics. Geometrically, it will be an orthoimage product, draped on Mars Orbiter Laser Altimeter (MOLA) derived topography, thus accounting properly for the commonly oblique VO imagery. Through the network being described here it will be tied to the newly defined IAU/IAG 2000 Mars coordinate system via ties to MOLA data. Thus, MDIM 2.1 will provide complete global orthorectified imagery coverage of Mars at the resolution of 1/256 deg of MDIM 2.0, and be compatible with MOLA and other products produced in the current coordinate system.
NASA Astrophysics Data System (ADS)
Boon, Choong S.; Guleryuz, Onur G.; Kawahara, Toshiro; Suzuki, Yoshinori
2006-08-01
We consider the mobile service scenario where video programming is broadcast to low-resolution wireless terminals. In such a scenario, broadcasters utilize simultaneous data services and bi-directional communications capabilities of the terminals in order to offer substantially enriched viewing experiences to users by allowing user participation and user tuned content. While users immediately benefit from this service when using their phones in mobile environments, the service is less appealing in stationary environments where a regular television provides competing programming at much higher display resolutions. We propose a fast super-resolution technique that allows the mobile terminals to show a much enhanced version of the broadcast video on nearby high-resolution devices, extending the appeal and usefulness of the broadcast service. The proposed single frame super-resolution algorithm uses recent sparse recovery results to provide high quality and high-resolution video reconstructions based solely on individual decoded frames provided by the low-resolution broadcast.
Gangodagamage, Chandana; Wullschleger, Stan
2014-07-03
The dataset represents microtopographic characterization of the ice-wedge polygon landscape in Barrow, Alaska. Three microtopographic features are delineated using 0.25 m high resolution digital elevation dataset derived from LiDAR. The troughs, rims, and centers are the three categories in this classification scheme. The polygon troughs are the surface expression of the ice-wedges that are in lower elevations than the interior polygon. The elevated shoulders of the polygon interior immediately adjacent to the polygon troughs are the polygon rims for the low center polygons. In case of high center polygons, these features are the topographic highs. In this classification scheme, both topographic highs and rims are considered as polygon rims. The next version of the dataset will include more refined classification scheme including separate classes for rims ad topographic highs. The interior part of the polygon just adjacent to the polygon rims are the polygon centers.
Evaluating the Ocean Component of the US Navy Earth System Model
NASA Astrophysics Data System (ADS)
Zamudio, L.
2017-12-01
Ocean currents, temperature, and salinity observations are used to evaluate the ocean component of the US Navy Earth System Model. The ocean and atmosphere components of the system are an eddy-resolving (1/12.5° equatorial resolution) version of the HYbrid Coordinate Ocean Model (HYCOM), and a T359L50 version of the NAVy Global Environmental Model (NAVGEM), respectively. The system was integrated in hindcast mode and the ocean results are compared against unassimilated observations, a stand-alone version of HYCOM, and the Generalized Digital Environment Model ocean climatology. The different observation types used in the system evaluation are: drifting buoys, temperature profiles, salinity profiles, and acoustical proxies (mixed layer depth, sonic layer depth, below layer gradient, and acoustical trapping). To evaluate the system's performance in each different metric, a scorecard is used to translate the system's errors into scores, which provide an indication of the system's skill in both space and time.
Libraries of High and Mid-Resolution Spectra of F, G, K, and M Field Stars
NASA Astrophysics Data System (ADS)
Montes, D.
1998-06-01
I have compiled here the three libraries of high and mid-resolution optical spectra of late-type stars I have recently published. The libraries include F, G, K and M field stars, from dwarfs to giants. The spectral coverage is from 3800 to 1000 Å, with spectral resolution ranging from 0.09 to 3.0 Å. These spectra include many of the spectral lines most widely used as optical and near-infrared indicators of chromospheric activity. The spectra have been obtained with the aim of providing a library of high and mid-resolution spectra to be used in the study of active chromosphere stars by applying a spectral subtraction technique. However, the data set presented here can also be utilized in a wide variety of ways. A digital version of all the fully reduced spectra is available via FTP and the World Wide Web (WWW) in FITS format.
NASA Technical Reports Server (NTRS)
Warren, W. H., Jr.
1984-01-01
The machine readable library as it is currently being distributed from the Astronomical Data Center is described. The library contains digital spectral for 161 stars of spectral classes O through M and luminosity classes 1, 3 and 5 in the wavelength range 3510 A to 7427 A. The resolution is approximately 4.5 A, while the typical photometric uncertainty of each resolution element is approximately 1 percent and broadband variations are 3 percent. The documentation includes a format description, a table of the indigenous characteristics of the magnetic tape file, and a sample listing of logical records exactly as they are recorded on the tape.
NASA Astrophysics Data System (ADS)
Nikolakopoulos, Konstantinos G.
2017-09-01
A global digital surface model dataset named ALOS Global Digital Surface Model (AW3D30) with a horizontal resolution of approx. 30-meter mesh (1 arcsec) has been released by the Japan Aerospace Exploration Agency (JAXA). The dataset has been compiled with images acquired by the Advanced Land Observing Satellite "DAICHI" (ALOS) and it is published based on the DSM dataset (5-meter mesh version) of the "World 3D Topographic Data", which is the most precise global-scale elevation data at this time, and its elevation precision is also at a world-leading level as a 30-meter mesh version. In this study the accuracy of ALOS AW3D30 was examined. For an area with complex geomorphologic characteristics DSM from ALOS stereo pairs were created with classical photogrammetric techniques. Those DSMs were compared with the ALOS AW3D30. Points of certified elevation collected with DGPS have been used to estimate the accuracy of the DSM. The elevation difference between the two DSMs was calculated. 2D RMSE, correlation and the percentile value were also computed and the results are presented.
Surface mineral maps of Afghanistan derived from HyMap imaging spectrometer data, version 2
Kokaly, Raymond F.; King, Trude V.V.; Hoefen, Todd M.
2013-01-01
This report presents a new version of surface mineral maps derived from HyMap imaging spectrometer data collected over Afghanistan in the fall of 2007. This report also describes the processing steps applied to the imaging spectrometer data. The 218 individual flight lines composing the Afghanistan dataset, covering more than 438,000 square kilometers, were georeferenced to a mosaic of orthorectified Landsat images. The HyMap data were converted from radiance to reflectance using a radiative transfer program in combination with ground-calibration sites and a network of cross-cutting calibration flight lines. The U.S. Geological Survey Material Identification and Characterization Algorithm (MICA) was used to generate two thematic maps of surface minerals: a map of iron-bearing minerals and other materials, which have their primary absorption features at the shorter wavelengths of the reflected solar wavelength range, and a map of carbonates, phyllosilicates, sulfates, altered minerals, and other materials, which have their primary absorption features at the longer wavelengths of the reflected solar wavelength range. In contrast to the original version, version 2 of these maps is provided at full resolution of 23-meter pixel size. The thematic maps, MICA summary images, and the material fit and depth images are distributed in digital files linked to this report, in a format readable by remote sensing software and Geographic Information Systems (GIS). The digital files can be downloaded from http://pubs.usgs.gov/ds/787/downloads/.
NOAA Data Rescue of Key Solar Databases and Digitization of Historical Solar Images
NASA Astrophysics Data System (ADS)
Coffey, H. E.
2006-08-01
Over a number of years, the staff at NOAA National Geophysical Data Center (NGDC) has worked to rescue key solar databases by converting them to digital format and making them available via the World Wide Web. NOAA has had several data rescue programs where staff compete for funds to rescue important and critical historical data that are languishing in archives and at risk of being lost due to deteriorating condition, loss of any metadata or descriptive text that describe the databases, lack of interest or funding in maintaining databases, etc. The Solar-Terrestrial Physics Division at NGDC was able to obtain funds to key in some critical historical tabular databases. Recently the NOAA Climate Database Modernization Program (CDMP) funded a project to digitize historical solar images, producing a large online database of historical daily full disk solar images. The images include the wavelengths Calcium K, Hydrogen Alpha, and white light photos, as well as sunspot drawings and the comprehensive drawings of a multitude of solar phenomena on one daily map (Fraunhofer maps and Wendelstein drawings). Included in the digitization are high resolution solar H-alpha images taken at the Boulder Solar Observatory 1967-1984. The scanned daily images document many phases of solar activity, from decadal variation to rotational variation to daily changes. Smaller versions are available online. Larger versions are available by request. See http://www.ngdc.noaa.gov/stp/SOLAR/ftpsolarimages.html. The tabular listings and solar imagery will be discussed.
Characterization of ASTER GDEM Elevation Data over Vegetated Area Compared with Lidar Data
NASA Technical Reports Server (NTRS)
Ni, Wenjian; Sun, Guoqing; Ranson, Kenneth J.
2013-01-01
Current researches based on areal or spaceborne stereo images with very high resolutions (less than 1 meter) have demonstrated that it is possible to derive vegetation height from stereo images. The second version of the Advanced Spaceborne Thermal Emission and Reflection Radiometer Global Digital Elevation Model (ASTER GDEM) is a state-of-the-art global elevation data-set developed by stereo images. However, the resolution of ASTER stereo images (15 meters) is much coarser than areal stereo images, and the ASTER GDEM is compiled products from stereo images acquired over 10 years. The forest disturbances as well as forest growth are inevitable in 10 years time span. In this study, the features of ASTER GDEM over vegetated areas under both flat and mountainous conditions were investigated by comparisons with lidar data. The factors possibly affecting the extraction of vegetation canopy height considered include (1) co-registration of DEMs; (2) spatial resolution of digital elevation models (DEMs); (3) spatial vegetation structure; and (4) terrain slope. The results show that accurate co-registration between ASTER GDEM and the National Elevation Dataset (NED) is necessary over mountainous areas. The correlation between ASTER GDEM minus NED and vegetation canopy height is improved from 0.328 to 0.43 by degrading resolutions from 1 arc-second to 5 arc-seconds and further improved to 0.6 if only homogenous vegetated areas were considered.
Noreen, Eric
2000-01-01
These images were processed from a raw format using Integrated Software for Images and Spectrometers (ISIS) to perform radiometric corrections and projection. All the images were projected in sinusoidal using a center longitude of 0 degrees. There are two versions of the mosaic, one unfiltered (sinusmos.tif), and one produced with all images processed through a box filter with an averaged pixel tone of 7.5 (sinusmosflt.tif). Both mosaics are ArcView-ArcInfo(2) ready in TIF format with associated world files (*.tfw).
Noreen, Eric
2000-01-01
These images were processed from a raw format using Integrated Software for Images and Spectrometers (ISIS) to perform radiometric corrections and projection. All the images were projected in sinusoidal using a center longitude of 70 degrees. There are two versions of the mosaic, one unfiltered (vallesmos.tif), and one produced with all images processed through a box filter with an averaged pixel tone of 7.699 (vallesmosflt.tif). Both mosaics are ArcView-ArcInfo ready in TIF format with associated world files (*.tfw).
A compact, multichannel, and low noise arbitrary waveform generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Govorkov, S.; Ivanov, B. I.; Novosibirsk State Technical University, K.Marx-Ave. 20, Novosibirsk 630092
2014-05-15
A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analogmore » compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.« less
NASA Astrophysics Data System (ADS)
Pan, Bing; Wang, Bo
2017-10-01
Digital volume correlation (DVC) is a powerful technique for quantifying interior deformation within solid opaque materials and biological tissues. In the last two decades, great efforts have been made to improve the accuracy and efficiency of the DVC algorithm. However, there is still a lack of a flexible, robust and accurate version that can be efficiently implemented in personal computers with limited RAM. This paper proposes an advanced DVC method that can realize accurate full-field internal deformation measurement applicable to high-resolution volume images with up to billions of voxels. Specifically, a novel layer-wise reliability-guided displacement tracking strategy combined with dynamic data management is presented to guide the DVC computation from slice to slice. The displacements at specified calculation points in each layer are computed using the advanced 3D inverse-compositional Gauss-Newton algorithm with the complete initial guess of the deformation vector accurately predicted from the computed calculation points. Since only limited slices of interest in the reference and deformed volume images rather than the whole volume images are required, the DVC calculation can thus be efficiently implemented on personal computers. The flexibility, accuracy and efficiency of the presented DVC approach are demonstrated by analyzing computer-simulated and experimentally obtained high-resolution volume images.
López, Enrique; Steiner, Alexander J; Hardy, David J; IsHak, Waguih W; Anderson, W Brantley
2016-01-01
This study explored within-subjects differences in the performance of 40 bilingual participants on the English and Spanish versions of the Wechsler Adult Intelligence Scale (WAIS) Digit Span task. To test the linguistic hypothesis that individuals would perform worse in Spanish because of its syllabic demand, we compared the number of syllables correctly recalled by each participant for every correct trial. Our analysis of the correct number of syllables remembered per trial showed that participants performed significantly better (i.e., recalling more syllables) in Spanish than in English on the total score. Findings suggest the Spanish version of the Digit Span (total score) was significantly more difficult than the English version utilizing traditional scoring methods. Moreover, the Forward Trial, rather than the Backward Trial, was more likely to show group differences between both language versions. Additionally, the Spanish trials of the Digit Span were correlated with language comprehension and verbal episodic memory measures, whereas the English trials of the Digit Span were correlated with confrontational naming and verbal fluency tasks. The results suggest that more research is necessary to further investigate other cognitive factors, rather than just syllabic demand, that might contribute to performance and outcome differences on the WAIS Digit Span in Spanish-English bilinguals.
A web-system of virtual morphometric globes
NASA Astrophysics Data System (ADS)
Florinsky, Igor; Garov, Andrei; Karachevtseva, Irina
2017-04-01
Virtual globes — programs implementing interactive three-dimensional (3D) models of planets — are increasingly used in geo- and planetary sciences. We develop a web-system of virtual morphometric globes. As the initial data, we used the following global digital elevation models (DEMs): (1) a DEM of the Earth extracted from SRTM30_PLUS database; (2) a DEM of Mars extracted from the Mars Orbiter Laser Altimeter (MOLA) gridded data record archive; and (3) A DEM of the Moon extracted from the Lunar Orbiter Laser Altimeter (LOLA) gridded data record archive. From these DEMs, we derived global digital models of the following 16 local, nonlocal, and combined morphometric variables: horizontal curvature, vertical curvature, mean curvature, Gaussian curvature, minimal curvature, maximal curvature, unsphericity curvature, difference curvature, vertical excess curvature, horizontal excess curvature, ring curvature, accumulation curvature, catchment area, dispersive area, topographic index, and stream power index (definitions, formulae, and interpretations can be found elsewhere [1]). To calculate local morphometric variables, we applied a finite-difference method intended for spheroidal equal angular grids [1]. Digital models of a nonlocal and combined morphometric variables were derived by a method of Martz and de Jong adapted to spheroidal equal angular grids [1]. DEM processing was performed in the software LandLord [1]. The calculated morphometric models were integrated into the testing version of the system. The following main functions are implemented in the system: (1) selection of a celestial body; (2) selection of a morphometric variable; (3) 2D visualization of a calculated global morphometric model (a map in equirectangular projection); (4) 3D visualization of a calculated global morphometric model on the sphere surface (a globe by itself); (5) change of a globe scale (zooming); and (6) globe rotation by an arbitrary angle. The testing version of the system represents morphometric models with the resolution of 15'. In the final version of the system, we plan to implement a multiscale 3D visualization for models of 17 morphometric variables with the resolution from 15' to 30". The web-system of virtual morphometric globes is designed as a separate unit of a 3D web GIS for storage, processing, and access to planetary data [2], which is currently developed as an extension of an existing 2D web GIS (http://cartsrv.mexlab.ru/geoportal). Free, real-time web access to the system of virtual globes will be provided. The testing version of the system is available at: http://cartsrv.mexlab.ru/virtualglobe. The study is supported by the Russian Foundation for Basic Research, grant 15-07-02484. References 1. Florinsky, I.V., 2016. Digital Terrain Analysis in Soil Science and Geology. 2nd ed. Academic Press, Amsterdam, 486 p. 2. Garov, A.S., Karachevtseva, I.P., Matveev, E.V., Zubarev, A.E., and Florinsky, I.V., 2016. Development of a heterogenic distributed environment for spatial data processing using cloud technologies. International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, 41(B4): 385-390.
Digital Systems Validation Handbook. Volume 2. Chapter 18. Avionic Data Bus Integration Technology
1993-11-01
interaction between a digital data bus and an avionic system. Very Large Scale Integration (VLSI) ICs and multiversion software, which make up digital...1984, the Sperry Corporation developed a fault tolerant system which employed multiversion programming, voting, and monitoring for error detection and...formulate all the significant behavior of a system. MULTIVERSION PROGRAMMING. N-version programming. N-VERSION PROGRAMMING. The independent coding of a
Servomotor and Controller Having Large Dynamic Range
NASA Technical Reports Server (NTRS)
Alhorn, Dean C.; Howard, David E.; Smith, Dennis A.; Dutton, Ken; Paulson, M. Scott
2007-01-01
A recently developed micro-commanding rotational-position-control system offers advantages of less mechanical complexity, less susceptibility to mechanical resonances, less power demand, less bulk, less weight, and lower cost, relative to prior rotational-position-control systems based on stepping motors and gear drives. This system includes a digital-signal- processor (DSP)-based electronic controller, plus a shaft-angle resolver and a servomotor mounted on the same shaft. Heretofore, micro-stepping has usually been associated with stepping motors, but in this system, the servomotor is micro-commanded in response to rotational-position feedback from the shaft-angle resolver. The shaft-angle resolver is of a four-speed type chosen because it affords four times the resolution of a single-speed resolver. A key innovative aspect of this system is its position-feedback signal- conditioning circuits, which condition the resolver output signal for multiple ranges of rotational speed. In the preferred version of the system, two rotational- speed ranges are included, but any number of ranges could be added to expand the speed range or increase resolution in particular ranges. In the preferred version, the resolver output is conditioned with two resolver-to-digital converters (RDCs). One RDC is used for speeds from 0.00012 to 2.5 rpm; the other RDC is used for speeds of 2.5 to 6,000 rpm. For the lower speed range, the number of discrete steps of RDC output per revolution was set at 262,144 (4 quadrants at 16 bits per quadrant). For the higher speed range, the number of discrete steps per revolution was set at 4,096 (4 quadrants at 10 bits per quadrant).
NASA Astrophysics Data System (ADS)
Koubaa, Zied
The communication network and the detection mechanisms are two critical systems in a plane. Their performance has a direct impact on aircrafts. This is of particular interest for avionics designers, who have increasingly invested more and more in the development of these elements. As a part of a project in this domain, we introduce the design and the development of a smart interface for position sensors dedicated to flights (Smart Sensor Interface - SSI). This interface will serve to connect sensors of different technologies (electromagnetic, optical and MEMS) to the new communication network, AFDX. The role of this interface is to generate an appropriate excitation signal for certain types of sensors (R/LVDT), and to treat, demodulate, and digitize their output signals. The proposed interface is thus composed of a Signal Acquisition Path (SAP) and an Excitation Signal Generation (ESG). By adopting the Integrated Modular Avionics architecture (IMA), we can minimize the size of the classic interface, reduce its energy consumption and improve its reliability and its performance. The focus of our design is particularly on the Data Acquisition Path (DAP). An Architecture characterized by a high resolution (14 bits) and a low latency (1.2 ms) of this module is introduced and developed in this prestigious work. This architecture was developed after a wellconducted study of existing solutions found in literature work and a detailed analysis of the problems arise in the design and implementation of this system (DAP). The conversion of the sensor signal into a digital signal is the most important step in acquiring data, as it sets the resolution of the acquired information and generates the majority of its latency. This module can also affect the reliability and stability of the system. Among different models and architectures, the Delta-Sigma analog-to-digital converter (ADC) is preferred for this application (for better resolution). This converter is formed by an analog circuit (modulator) followed by digital filters. The complexity of the implementation, the processing delay and the output resolution are all susceptible to change depending on the architecture of these filters. Thus, the main problem while designing such a system arises in the opposing evolution of the resolution and latency parameters; the improvement or evolution of one, results in the destruction of the other. Therefore, our work aims to provide one or more method to optimize the latency caused by the CAN while maintaining the same resolution of the desired data (14 bits). This optimization takes into account the objective of integrating the DAP in modules of small size and low power consumption. This proposed solution was implemented in order to validate the design of the conception of the interface. We are also interested to achieve the proposed solution and validate our design. The obtained results will be evaluated after following the manufacturing strategy. The data acquisition unit is made up of two electronic components. The first component is an integrated circuit, which uses CMOS 0.13mum IBM technology and contains the analog part of CAN (SigmaDelta modulator). The second component is a Virtex-6 FPGA, which allows one to acquire the necessary digital processing required for the acquisition and conversion of the sensor signal. In the final version of the interface, our analog portion will be integrated with the analog portion of GSE in the same chip. The integrated digital logic in the (FPGA) role will thus provide digital data to the ESG module in order to generate the excitation signal.
Image resolution in the digital era: notion and clinical implications.
Rakhshan, Vahid
2014-12-01
Digital radiographs need additional metadata in order to be accurate when being converted to analog media. Resolution is a major reason of failures in proper printing or digitizing the images. This letter shortly explains the overlooked pitfalls of digital radiography and photography in dental practice, and briefly instructs the reader how to avoid or rectify common problems associated with resolution calibration of digital radiographs.
GLOBATO: An enhanced global relief model at 30 arc-seconds resolution
NASA Astrophysics Data System (ADS)
O'Leary, V.; Amante, C.
2017-12-01
The National Centers for Environmental Information (NCEI), an office of the National Oceanic and Atmospheric Administration (NOAA), first developed a digital bathymetric and elevation model, ETOPO5, from publicly available data in 1993. For nearly 25 years, NCEI's ETOPO family of global relief models have supported research at a planetary scale, including tsunami forecasting, ocean circulation modeling, visualization of the seafloor, understanding geological phenomena, and aiding the development of other global and regional elevation models. GLOBATO (GLObal BAThymetry and TOpography) is now the most detailed version released by NCEI with a horizontal resolution of 30 arc-seconds and succeeds ETOPO1 with the inclusion of several new or updated data-sets for the seafloor as well as land areas. GLOBATO is a compilation of data derived from models of satellite measurements, ship depth soundings, and multibeam surveys, as well as regional models developed for Greenland and Antarctica. These data were converted from different formats, resolutions, spatial distributions, and projections into a single global model using GDAL v2.2 and MB-System v5.5. As with previous NCEI models, GLOBATO is available in two formats, "bedrock elevation" (measured as the base of major ice sheets) and "ice surface elevation" (measured as the surface of major ice sheets) which provides comprehensive topographic and bathymetric coverage between +- 90 degrees latitude and +- 180 degrees longitude. Adhering to best practices, GLOBATO, all related digital products, and any supporting documentation are available online through the NCEI data portal. These new, high resolution models will better support the variety of research ETOPO1 has made possible.
Interformat reliability of digital psychiatric self-report questionnaires: a systematic review.
Alfonsson, Sven; Maathz, Pernilla; Hursti, Timo
2014-12-03
Research on Internet-based interventions typically use digital versions of pen and paper self-report symptom scales. However, adaptation into the digital format could affect the psychometric properties of established self-report scales. Several studies have investigated differences between digital and pen and paper versions of instruments, but no systematic review of the results has yet been done. This review aims to assess the interformat reliability of self-report symptom scales used in digital or online psychotherapy research. Three databases (MEDLINE, Embase, and PsycINFO) were systematically reviewed for studies investigating the reliability between digital and pen and paper versions of psychiatric symptom scales. From a total of 1504 publications, 33 were included in the review, and interformat reliability of 40 different symptom scales was assessed. Significant differences in mean total scores between formats were found in 10 of 62 analyses. These differences were found in just a few studies, which indicates that the results were due to study effects and sample effects rather than unreliable instruments. The interformat reliability ranged from r=.35 to r=.99; however, the majority of instruments showed a strong correlation between format scores. The quality of the included studies varied, and several studies had insufficient power to detect small differences between formats. When digital versions of self-report symptom scales are compared to pen and paper versions, most scales show high interformat reliability. This supports the reliability of results obtained in psychotherapy research on the Internet and the comparability of the results to traditional psychotherapy research. There are, however, some instruments that consistently show low interformat reliability, suggesting that these conclusions cannot be generalized to all questionnaires. Most studies had at least some methodological issues with insufficient statistical power being the most common issue. Future studies should preferably provide information about the transformation of the instrument into digital format and the procedure for data collection in more detail.
Procedures and Guidelines for Digitization (Scanning)
These documents establishes EPA's approach for creating digitized versions of Agency documents and establishes standards for capturing digitized content from paper and microform Agency documents and records.
NASA Astrophysics Data System (ADS)
Ding, Keyang; Gronenborn, Angela M.
2004-04-01
Sensitivity-enhanced 2D IPAP experiments using the accordion principle for measuring one-bond 13C '- 13C α and 1H α- 13C α dipolar couplings in proteins are presented. The resolution of the resulting spectra is identical to that of the decoupled HSQC spectra and the sensitivity of the corresponding 1D acquisitions are only slightly lower than those obtained with 3D HNCO and 3D HN(COCA)HA pulse sequences due to an additional delay 2 Δ. For cases of limited resolution in the 2D 15N- 1H N HSQC spectrum the current pulse sequences can easily be modified into 3D versions by introducing a poorly digitized third dimension, if so desired. The experiments described here are a valuable addition to the suites available for determination of residual dipolar couplings in biological systems.
Synthetic aperture in terahertz in-line digital holography for resolution enhancement.
Huang, Haochong; Rong, Lu; Wang, Dayong; Li, Weihua; Deng, Qinghua; Li, Bin; Wang, Yunxin; Zhan, Zhiqiang; Wang, Xuemin; Wu, Weidong
2016-01-20
Terahertz digital holography is a combination of terahertz technology and digital holography. In digital holography, the imaging resolution is the key parameter in determining the detailed quality of a reconstructed wavefront. In this paper, the synthetic aperture method is used in terahertz digital holography and the in-line arrangement is built to perform the detection. The resolved capability of previous terahertz digital holographic systems restricts this technique to meet the requirement of practical detection. In contrast, the experimental resolved power of the present method can reach 125 μm, which is the best resolution of terahertz digital holography to date. Furthermore, the basic detection of a biological specimen is conducted to show the practical application. In all, the results of the proposed method demonstrate the enhancement of experimental imaging resolution and that the amplitude and phase distributions of the fine structure of samples can be reconstructed by using terahertz digital holography.
Digital Shaded-Relief Image of Alaska
Riehle, J.R.; Fleming, Michael D.; Molnia, B.F.; Dover, J.H.; Kelley, J.S.; Miller, M.L.; Nokleberg, W.J.; Plafker, George; Till, A.B.
1997-01-01
Introduction One of the most spectacular physiographic images of the conterminous United States, and the first to have been produced digitally, is that by Thelin and Pike (USGS I-2206, 1991). The image is remarkable for its crispness of detail and for the natural appearance of the artificial land surface. Our goal has been to produce a shaded-relief image of Alaska that has the same look and feel as the Thelin and Pike image. The Alaskan image could have been produced at the same scale as its lower 48 counterpart (1:3,500,000). But by insetting the Aleutian Islands into the Gulf of Alaska, we were able to print the Alaska map at a larger scale (1:2,500,000) and about the same physical size as the Thelin and Pike image. Benefits of the 1:2,500,000 scale are (1) greater resolution of topographic features and (2) ease of reference to the U.S. Geological Survey (USGS) (1987) Alaska Map E and the statewide geologic map (Beikman, 1980), which are both 1:2,500,000 scale. Manually drawn, shaded-relief images of Alaska's land surface have long been available (for example, Department of the Interior, 1909; Raisz, 1948). The topography depicted on these early maps is mainly schematic. Maps showing topographic contours were first available for the entire State in 1953 (USGS, 1:250,000) (J.H. Wittmann, USGS, written commun., 1996). The Alaska Map E was initially released in 1954 in both planimetric (revised in 1973 and 1987) and shaded-relief versions (revised in 1973, 1987, and 1996); topography depicted on the shaded-relief version is based on the 1:250,000-scale USGS topographic maps. Alaska Map E was later modified to include hypsometric tinting by Raven Maps and Images (1989, revised 1993) as copyrighted versions. Other shaded-relief images were produced for The National Geographic Magazine (LaGorce, 1956; 1:3,000,000) or drawn by Harrison (1970; 1:7,500,000) for The National Atlas of the United States. Recently, the State of Alaska digitally produced a shaded-relief image of Alaska at 1:2,500,000 scale (Alaska Department of Natural Resources, 1994), using the 1,000-m digital elevation data set referred to below. An important difference between our image and these previous ones is the method of reproduction: like the Thelin and Pike (1991) image, our image is a composite of halftone images that yields sharp resolution and preserves contrast. Indeed, the first impression of many viewers is that the Alaskan image and the Thelin and Pike image are composites of satellite-generated photographs rather than an artificial rendering of a digital elevation model. A shaded-relief image represents landforms in a natural fashion; that is, a viewer perceives the image as a rendering of reality. Thus a shaded-relief image is intrinsically appealing, especially in areas of spectacular relief. In addition, even subtle physiographic features that reflect geologic structures or the type of bedrock are visible. To our knowledge, some of these Alaskan features have not been depicted before and so the image should provide earth scientists with a new 'look' at fundamental geologic features of Alaska.
NASA Technical Reports Server (NTRS)
Clark, Roger N.; Swayze, Gregg A.
1995-01-01
One of the challenges of Imaging Spectroscopy is the identification, mapping and abundance determination of materials, whether mineral, vegetable, or liquid, given enough spectral range, spectral resolution, signal to noise, and spatial resolution. Many materials show diagnostic absorption features in the visual and near infrared region (0.4 to 2.5 micrometers) of the spectrum. This region is covered by the modern imaging spectrometers such as AVIRIS. The challenge is to identify the materials from absorption bands in their spectra, and determine what specific analyses must be done to derive particular parameters of interest, ranging from simply identifying its presence to deriving its abundance, or determining specific chemistry of the material. Recently, a new analysis algorithm was developed that uses a digital spectral library of known materials and a fast, modified-least-squares method of determining if a single spectral feature for a given material is present. Clark et al. made another advance in the mapping algorithm: simultaneously mapping multiple minerals using multiple spectral features. This was done by a modified-least-squares fit of spectral features, from data in a digital spectral library, to corresponding spectral features in the image data. This version has now been superseded by a more comprehensive spectral analysis system called Tricorder.
The Role of Original Version Cinema into the European Digital Space
ERIC Educational Resources Information Center
Ledo-Andión, Margarita; López-Gómez, Antía; Castelló-Mayo, Enrique
2017-01-01
This paper reports the results derived from the research project, entitled "eDCINEMA: Towards the European Digital Space. The role of small cinemas in original version" (CSO2012-35784), which focused on the analysis of the role of movies in OV/OVS in achieving diversity of languages and cultures (as viewed from the European Digital…
1991-10-28
included as appropriate. 2-1 IMPLEMENTATION DEPENDENCIES The following 185 tests have floating-point type declarations requiring more digits than...SYSTEM.MAX DIGITS : C24113F..Y (20 tests) C? 705F..Y (20 tests) C35706F..Y (20 tests) C35707F..Y (20 tests) C35708F..Y (20 tests) C35802F..Z (21 tests...trademark of Teleoft. TeleGen2m is a trademark of TeleSofL VAX and VMS! are registered trademarks of Digital Equipment Corp. RESTRICTED RIGHTS LEGEND Use
Transmission of digital images within the NTSC analog format
Nickel, George H.
2004-06-15
HDTV and NTSC compatible image communication is done in a single NTSC channel bandwidth. Luminance and chrominance image data of a scene to be transmitted is obtained. The image data is quantized and digitally encoded to form digital image data in HDTV transmission format having low-resolution terms and high-resolution terms. The low-resolution digital image data terms are transformed to a voltage signal corresponding to NTSC color subcarrier modulation with retrace blanking and color bursts to form a NTSC video signal. The NTSC video signal and the high-resolution digital image data terms are then transmitted in a composite NTSC video transmission. In a NTSC receiver, the NTSC video signal is processed directly to display the scene. In a HDTV receiver, the NTSC video signal is processed to invert the color subcarrier modulation to recover the low-resolution terms, where the recovered low-resolution terms are combined with the high-resolution terms to reconstruct the scene in a high definition format.
NASA Astrophysics Data System (ADS)
Souza, D. M.; Costa, I. A.; Nóbrega, R. A.
2017-10-01
This document presents a detailed study of the performance of a set of digital filters whose implementations are based on the best linear unbiased estimator theory interpreted as a constrained optimization problem that could be relaxed depending on the input signal characteristics. This approach has been employed by a number of recent particle physics experiments for measuring the energy of particle events interacting with their detectors. The considered filters have been designed to measure the peak amplitude of signals produced by their detectors based on the digitized version of such signals. This study provides a clear understanding of the characteristics of those filters in the context of particle physics and, additionally, it proposes a phase related constraint based on the second derivative of the Taylor expansion in order to make the estimator less sensitive to phase variation (phase between the analog signal shaping and its sampled version), which is stronger in asynchronous experiments. The asynchronous detector developed by the ν-Angra Collaboration is used as the basis for this work. Nevertheless, the proposed analysis goes beyond, considering a wide range of conditions related to signal parameters such as pedestal, phase, sampling rate, amplitude resolution, noise and pile-up; therefore crossing the bounds of the ν-Angra Experiment to make it interesting and useful for different asynchronous and even synchronous experiments.
Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research
NASA Astrophysics Data System (ADS)
Bergeron, Mélanie; Cadorette, Jules; Tétrault, Marc-André; Beaudoin, Jean-François; Leroux, Jean-Daniel; Fontaine, Réjean; Lecomte, Roger
2014-02-01
The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm3), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250-650 keV) and a high-resolution mode (350-650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250-650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250-650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml-1. With the same phantom, the scatter fraction for all scanners is about 17% for an energy threshold of 250 keV and 10% for an energy threshold of 350 keV. The results obtained with two energy window settings confirm the relevance of high-efficiency and high-resolution operating modes to take full advantage of the imaging capabilities of the LabPET scanners for molecular imaging applications.
Ryder, Robert T.; Repetski, John E.; Harris, Anita G.; Lentz, Erika E.; Ruppert, Leslie F.; Ryder, Robert T.
2014-01-01
This chapter is a re-release of U.S. Geological Survey Miscellaneous Investigations Series Map I-2530, of the same title, by Ryder and others (1997; online version 2.0 revised and digitized by Erika E. Lentz, 2004). Version 2.0 is a digital version of the original and also includes the gamma-ray well log traces.
A daily, 1 km resolution data set of downscaled Greenland ice sheet surface mass balance (1958-2015)
NASA Astrophysics Data System (ADS)
Noël, Brice; van de Berg, Willem Jan; Machguth, Horst; Lhermitte, Stef; Howat, Ian; Fettweis, Xavier; van den Broeke, Michiel R.
2016-10-01
This study presents a data set of daily, 1 km resolution Greenland ice sheet (GrIS) surface mass balance (SMB) covering the period 1958-2015. Applying corrections for elevation, bare ice albedo and accumulation bias, the high-resolution product is statistically downscaled from the native daily output of the polar regional climate model RACMO2.3 at 11 km. The data set includes all individual SMB components projected to a down-sampled version of the Greenland Ice Mapping Project (GIMP) digital elevation model and ice mask. The 1 km mask better resolves narrow ablation zones, valley glaciers, fjords and disconnected ice caps. Relative to the 11 km product, the more detailed representation of isolated glaciated areas leads to increased precipitation over the southeastern GrIS. In addition, the downscaled product shows a significant increase in runoff owing to better resolved low-lying marginal glaciated regions. The combined corrections for elevation and bare ice albedo markedly improve model agreement with a newly compiled data set of ablation measurements.
A method of determining attitude from magnetometer data only
NASA Technical Reports Server (NTRS)
Natanson, G. A.; Mclaughlin, S. F.; Nicklas, R. C.
1990-01-01
Presented here is a new algorithm to determine attitude using only magnetometer data under the following conditions: (1) internal torques are known and (2) external torques are negligible. Torque-free rotation of a spacecraft in thruster firing acquisition phase and its magnetic despin in the B-dot mode give typical examples of such situations. A simple analytical formula has been derived in the limiting case of a spacecraft rotating with constant angular velocity. The formula has been tested using low-frequency telemetry data for the Earth Radiation Budget Satellite (ERBS) under normal conditions. Observed small oscillation of body-fixed components of the angular velocity vector near their mean values result in relatively minor errors of approximately 5 degrees. More significant errors come from processing digital magnetometer data. Higher resolution of digitized magnetometer measurements would significantly improve the accuracy of this deterministic scheme. Tests of the general version of the developed algorithm for a free-rotating spacecraft and for the B-dot mode are in progress.
High-resolution digital holography with the aid of coherent diffraction imaging.
Jiang, Zhilong; Veetil, Suhas P; Cheng, Jun; Liu, Cheng; Wang, Ling; Zhu, Jianqiang
2015-08-10
The image reconstructed in ordinary digital holography was unable to bring out desired resolution in comparison to photographic materials; thus making it less preferable for many interesting applications. A method is proposed to enhance the resolution of digital holography in all directions by placing a random phase plate between the specimen and the electronic camera and then using an iterative approach to do the reconstruction. With this method, the resolution is improved remarkably in comparison to ordinary digital holography. Theoretical analysis is supported by numerical simulation. The feasibility of the method is also studied experimentally.
DeWitt, Nancy T.; Flocks, James G.; Pendleton, Elizabeth A.; Hansen, Mark E.; Reynolds, B.J.; Kelso, Kyle W.; Wiese, Dana S.; Worley, Charles R.
2012-01-01
See the digital FACS equipment log for details about the acquisition equipment used. Raw datasets are stored digitally at the USGS St. Petersburg Coastal and Marine Science Center and processed systematically using Novatel's GrafNav version 7.6, SANDS version 3.7, SEA SWATHplus version 3.06.04.03, CARIS HIPS AND SIPS version 3.6, and ESRI ArcGIS version 9.3.1. For more information on processing refer to the Equipment and Processing page. Chirp seismic data were also collected during these surveys and are archived separately.
2012-01-30
Behold one of the more detailed images of the Earth yet created. This Blue Marble Earth montage shown above -- created from photographs taken by the Visible/Infrared Imager Radiometer Suite (VIIRS) instrument on board the new Suomi NPP satellite -- shows many stunning details of our home planet. The Suomi NPP satellite was launched last October and renamed last week after Verner Suomi, commonly deemed the father of satellite meteorology. The composite was created from the data collected during four orbits of the robotic satellite taken earlier this month and digitally projected onto the globe. Many features of North America and the Western Hemisphere are particularly visible on a high resolution version of the image. http://photojournal.jpl.nasa.gov/catalog/PIA18033
ERIC Educational Resources Information Center
Association of Research Libraries, 2009
2009-01-01
Libraries are making diverse contributions to the development of many types of digital repositories, particularly those housing locally created digital content, including new digital objects or digitized versions of locally held works. In some instances, libraries are managing a repository and its related services entirely on their own, but often…
Palaseanu-Lovejoy, Monica; Poppenga, Sandra K.; Danielson, Jeffrey J.; Tyler, Dean J.; Gesch, Dean B.; Kottermair, Maria; Jalandoni, Andrea; Carlson, Edward; Thatcher, Cindy A.; Barbee, Matthew M.
2018-03-30
Atoll and island coastal communities are highly exposed to sea-level rise, tsunamis, storm surges, rogue waves, king tides, and the occasional combination of multiple factors, such as high regional sea levels, extreme high local tides, and unusually strong wave set-up. The elevation of most of these atolls averages just under 3 meters (m), with many areas roughly at sea level. The lack of high-resolution topographic data has been identified as a critical data gap for hazard vulnerability and adaptation efforts and for high-resolution inundation modeling for atoll nations. Modern topographic survey equipment and airborne lidar surveys can be very difficult and costly to deploy. Therefore, unmanned aircraft systems (UAS) were investigated for collecting overlapping imagery to generate topographic digital elevation models (DEMs). Medium- and high-resolution satellite imagery (Landsat 8 and WorldView-3) was investigated to derive nearshore bathymetry.The Republic of the Marshall Islands is associated with the United States through a Compact of Free Association, and Majuro Atoll is home to the capital city of Majuro and the largest population of the Republic of the Marshall Islands. The only elevation datasets currently available for the entire Majuro Atoll are the Shuttle Radar Topography Mission and the Advanced Spaceborne Thermal Emission and Reflection Radiometer Global Digital Elevation Model Version 2 elevation data, which have a 30-m grid-cell spacing and a 8-m vertical root mean square error (RMSE). Both these datasets have inadequate spatial resolution and vertical accuracy for inundation modeling.The final topobathymetric DEM (TBDEM) developed for Majuro Atoll is derived from various data sources including charts, soundings, acoustic sonar, and UAS and satellite imagery spanning over 70 years of data collection (1944 to 2016) on different sections of the atoll. The RMSE of the TBDEM over the land area is 0.197 m using over 70,000 Global Navigation Satellite System real-time kinematic survey points for validation, and 1.066 m for Landsat 8 and 1.112 m for WorldView-3 derived bathymetry using over 16,000 and 9,000 lidar bathymetry points, respectively.
ERIC Educational Resources Information Center
Inan, Mehmet; Dervent, Fatih; Özden, Bülent; Arslantas, Bülent
2015-01-01
The purpose of this study was to examine students' responses to the digital and the active version of Angry Birds™ according to students' mathematics grades. The relational screening model was used to reveal the relationship between the students' responses and their math grades. The participants were 26 elementary and secondary school students…
NASA Astrophysics Data System (ADS)
Jarihani, B.
2015-12-01
Digital Elevation Models (DEMs) that accurately replicate both landscape form and processes are critical to support modeling of environmental processes. Pre-processing analysis of DEMs and extracting characteristics of the watershed (e.g., stream networks, catchment delineation, surface and subsurface flow paths) is essential for hydrological and geomorphic analysis and sediment transport. This study investigates the status of the current remotely-sensed DEMs in providing advanced morphometric information of drainage basins particularly in data sparse regions. Here we assess the accuracy of three available DEMs: (i) hydrologically corrected "H-DEM" of Geoscience Australia derived from the Shuttle Radar Topography Mission (SRTM) data; (ii) the Advanced Spaceborne Thermal Emission and Reflection Radiometer Global Digital Elevation Model (ASTER GDEM) version2 1-arc-second (~30 m) data; and (iii) the 9-arc-second national GEODATA DEM-9S ver3 from Geoscience Australia and the Australian National University. We used ESRI's geospatial data model, Arc Hydro and HEC-GeoHMS, designed for building hydrologic information systems to synthesize geospatial and temporal water resources data that support hydrologic modeling and analysis. A coastal catchment in northeast Australia was selected as the study site where very high resolution LiDAR data are available for parts of the area as reference data to assess the accuracy of other lower resolution datasets. This study provides morphometric information for drainage basins as part of the broad research on sediment flux from coastal basins to Great Barrier Reef, Australia. After applying geo-referencing and elevation corrections, stream and sub basins were delineated for each DEM. Then physical characteristics for streams (i.e., length, upstream and downstream elevation, and slope) and sub-basins (i.e., longest flow lengths, area, relief and slopes) were extracted and compared with reference datasets from LiDAR. Results showed that, in the absence of high-precision and high resolution DEM data, ASTER GDEM or SRTM DEM can be used to extract common morphometric relationship which are widely used for hydrological and geomorphological modelling.
Refinement of ground reference data with segmented image data
NASA Technical Reports Server (NTRS)
Robinson, Jon W.; Tilton, James C.
1991-01-01
One of the ways to determine ground reference data (GRD) for satellite remote sensing data is to photo-interpret low altitude aerial photographs and then digitize the cover types on a digitized tablet and register them to 7.5 minute U.S.G.S. maps (that were themselves digitized). The resulting GRD can be registered to the satellite image or, vice versa. Unfortunately, there are many opportunities for error when using digitizing tablet and the resolution of the edges for the GRD depends on the spacing of the points selected on the digitizing tablet. One of the consequences of this is that when overlaid on the image, errors and missed detail in the GRD become evident. An approach is discussed for correcting these errors and adding detail to the GRD through the use of a highly interactive, visually oriented process. This process involves the use of overlaid visual displays of the satellite image data, the GRD, and a segmentation of the satellite image data. Several prototype programs were implemented which provide means of taking a segmented image and using the edges from the reference data to mask out these segment edges that are beyond a certain distance from the reference data edges. Then using the reference data edges as a guide, those segment edges that remain and that are judged not to be image versions of the reference edges are manually marked and removed. The prototype programs that were developed and the algorithmic refinements that facilitate execution of this task are described.
Resolution analysis of archive films for the purpose of their optimal digitization and distribution
NASA Astrophysics Data System (ADS)
Fliegel, Karel; Vítek, Stanislav; Páta, Petr; Myslík, Jiří; Pecák, Josef; Jícha, Marek
2017-09-01
With recent high demand for ultra-high-definition (UHD) content to be screened in high-end digital movie theaters but also in the home environment, film archives full of movies in high-definition and above are in the scope of UHD content providers. Movies captured with the traditional film technology represent a virtually unlimited source of UHD content. The goal to maintain complete image information is also related to the choice of scanning resolution and spatial resolution for further distribution. It might seem that scanning the film material in the highest possible resolution using state-of-the-art film scanners and also its distribution in this resolution is the right choice. The information content of the digitized images is however limited, and various degradations moreover lead to its further reduction. Digital distribution of the content in the highest image resolution might be therefore unnecessary or uneconomical. In other cases, the highest possible resolution is inevitable if we want to preserve fine scene details or film grain structure for archiving purposes. This paper deals with the image detail content analysis of archive film records. The resolution limit in captured scene image and factors which lower the final resolution are discussed. Methods are proposed to determine the spatial details of the film picture based on the analysis of its digitized image data. These procedures allow determining recommendations for optimal distribution of digitized video content intended for various display devices with lower resolutions. Obtained results are illustrated on spatial downsampling use case scenario, and performance evaluation of the proposed techniques is presented.
Comparison of In-Person vs. Digital Climate Education Program
NASA Astrophysics Data System (ADS)
Anderson, R. K.; Flora, J. A.; Saphir, M.
2017-12-01
In 2014, ACE (Alliance for Climate Education) evaluated the impact of its 45-minute live climate edutainment education program on the knowledge, attitudes and behavior of high school students with respect to climate change. The results showed gains in knowledge, increased engagement, as well as increased communication about climate change with number of students reporting talking about climate change with friends and family more than doubling. In 2016, ACE launched a digital version of its in-person edutainment education program, a 40-minute video version of the live program. This digital version, Our Climate Our Future (OCOF), has now been used by nearly 4,000 teachers nationwide and viewed by over 150,000 students. We experimentally tested the impact of the digital program (OCOF) compared to the live program and a control group. The experiment was conducted with 709 students in 27 classes at two North Carolina public high schools. Classes were assigned to one of three conditions: digital, live and control. In the digital version, students watched the 40-minute OCOF video featuring the same educator that presented the live program. In the live version, students received an identical 40-minute live presentation by an ACE staff educator The control group received neither treatment. When compared to controls, both programs were effective in positively increasing climate change knowledge, climate justice knowledge, perceived self-efficacy to make climate-friendly behavior changes, and beliefs about climate change (all statistically significant at or above P<.01). In the areas of hope that people can solve climate change and intent to change behavior, only the live program showed significant increases. In these two areas, it may be that an in-person experience is key to affecting change. In light of these positive results, ACE plans to increase the use of OCOF in schools across the country to assist teachers in their efforts to teach about climate change.
Comparison of In-Person vs. Digital Climate Education Program
NASA Astrophysics Data System (ADS)
Anbar, A. D.; Elkins-Tanton, L. T.; Klug Boonstra, S.; Ben-Naim, D.
2016-12-01
In 2014, ACE (Alliance for Climate Education) evaluated the impact of its 45-minute live climate edutainment education program on the knowledge, attitudes and behavior of high school students with respect to climate change. The results showed gains in knowledge, increased engagement, as well as increased communication about climate change with number of students reporting talking about climate change with friends and family more than doubling. In 2016, ACE launched a digital version of its in-person edutainment education program, a 40-minute video version of the live program. This digital version, Our Climate Our Future (OCOF), has now been used by nearly 4,000 teachers nationwide and viewed by over 150,000 students. We experimentally tested the impact of the digital program (OCOF) compared to the live program and a control group. The experiment was conducted with 709 students in 27 classes at two North Carolina public high schools. Classes were assigned to one of three conditions: digital, live and control. In the digital version, students watched the 40-minute OCOF video featuring the same educator that presented the live program. In the live version, students received an identical 40-minute live presentation by an ACE staff educator The control group received neither treatment. When compared to controls, both programs were effective in positively increasing climate change knowledge, climate justice knowledge, perceived self-efficacy to make climate-friendly behavior changes, and beliefs about climate change (all statistically significant at or above P<.01). In the areas of hope that people can solve climate change and intent to change behavior, only the live program showed significant increases. In these two areas, it may be that an in-person experience is key to affecting change. In light of these positive results, ACE plans to increase the use of OCOF in schools across the country to assist teachers in their efforts to teach about climate change.
Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions
Pascual-Moscardó, Agustín; Camps, Isabel
2018-01-01
Background The scanner does not measure the dental surface continually. Instead, it generates a point cloud, and these points are then joined to form the scanned object. This approximation will depend on the number of points generated (resolution), which can lead to low accuracy (trueness and precision) when fewer points are obtained. The purpose of this study is to determine the resolution of four intraoral digital imaging systems and to demonstrate the relationship between accuracy and resolution of the intraoral scanner in impressions of a complete dental arch. Material and Methods A master cast of the complete maxillary arch was prepared with different dental preparations. Using four digital impression systems, the cast was scanned inside of a black methacrylate box, obtaining a total of 40 digital impressions from each scanner. The resolution was obtained by dividing the number of points of each digital impression by the total surface area of the cast. Accuracy was evaluated using a three-dimensional measurement software, using the “best alignment” method of the casts with a highly faithful reference model obtained from an industrial scanner. Pearson correlation was used for statistical analysis of the data. Results Of the intraoral scanners, Omnicam is the system with the best resolution, with 79.82 points per mm2, followed by True Definition with 54.68 points per mm2, Trios with 41.21 points per mm2, and iTero with 34.20 points per mm2. However, the study found no relationship between resolution and accuracy of the study digital impression systems (P >0.05), except for Omnicam and its precision. Conclusions The resolution of the digital impression systems has no relationship with the accuracy they achieve in the impression of a complete dental arch. The study found that the Omnicam scanner is the system that obtains the best resolution, and that as the resolution increases, its precision increases. Key words:Trueness, precision, accuracy, resolution, intraoral scanner, digital impression. PMID:29750097
User's Guide for the Agricultural Non-Point Source (AGNPS) Pollution Model Data Generator
Finn, Michael P.; Scheidt, Douglas J.; Jaromack, Gregory M.
2003-01-01
BACKGROUND Throughout this user guide, we refer to datasets that we used in conjunction with developing of this software for supporting cartographic research and producing the datasets to conduct research. However, this software can be used with these datasets or with more 'generic' versions of data of the appropriate type. For example, throughout the guide, we refer to national land cover data (NLCD) and digital elevation model (DEM) data from the U.S. Geological Survey (USGS) at a 30-m resolution, but any digital terrain model or land cover data at any appropriate resolution will produce results. Another key point to keep in mind is to use a consistent data resolution for all the datasets per model run. The U.S. Department of Agriculture (USDA) developed the Agricultural Nonpoint Source (AGNPS) pollution model of watershed hydrology in response to the complex problem of managing nonpoint sources of pollution. AGNPS simulates the behavior of runoff, sediment, and nutrient transport from watersheds that have agriculture as their prime use. The model operates on a cell basis and is a distributed parameter, event-based model. The model requires 22 input parameters. Output parameters are grouped primarily by hydrology, sediment, and chemical output (Young and others, 1995.) Elevation, land cover, and soil are the base data from which to extract the 22 input parameters required by the AGNPS. For automatic parameter extraction, follow the general process described in this guide of extraction from the geospatial data through the AGNPS Data Generator to generate input parameters required by the pollution model (Finn and others, 2002.)
Identification of stars and digital version of the catalogue of 1958 by Brodskaya and Shajn
NASA Astrophysics Data System (ADS)
Gorbunov, M. A.; Shlyapnikov, A. A.
2017-12-01
The following topics are considered: the identification of objects on search maps, the determination of their coordinates at the epoch of 2000, and converting the published version of the catalogue of 1958 by Brodskaya and Shajn into a machine-readable format. The statistics for photometric and spectral data from the original catalogue is presented. A digital version of the catalogue is described, as well as its presentation in HTML, VOTable and AJS formats and the basic principles of work in the interactive application of International Virtual Observatory - the Aladin Sky Atlas.
Geologic map of the eastern part of the Challis National Forest and vicinity, Idaho
Wilson, A.B.; Skipp, B.A.
1994-01-01
The paper version of the Geologic Map of the eastern part of the Challis National Forest and vicinity, Idaho was compiled by Anna Wilson and Betty Skipp in 1994. The geology was compiled on a 1:250,000 scale topographic base map. TechniGraphic System, Inc. of Fort Collins Colorado digitized this map under contract for N.Shock. G.Green edited and prepared the digital version for publication as a GIS database. The digital geologic map database can be queried in many ways to produce a variety of geologic maps.
A Low Power Digital Accumulation Technique for Digital-Domain CMOS TDI Image Sensor.
Yu, Changwei; Nie, Kaiming; Xu, Jiangtao; Gao, Jing
2016-09-23
In this paper, an accumulation technique suitable for digital domain CMOS time delay integration (TDI) image sensors is proposed to reduce power consumption without degrading the rate of imaging. In terms of the slight variations of quantization codes among different pixel exposures towards the same object, the pixel array is divided into two groups: one is for coarse quantization of high bits only, and the other one is for fine quantization of low bits. Then, the complete quantization codes are composed of both results from the coarse-and-fine quantization. The equivalent operation comparably reduces the total required bit numbers of the quantization. In the 0.18 µm CMOS process, two versions of 16-stage digital domain CMOS TDI image sensor chains based on a 10-bit successive approximate register (SAR) analog-to-digital converter (ADC), with and without the proposed technique, are designed. The simulation results show that the average power consumption of slices of the two versions are 6 . 47 × 10 - 8 J/line and 7 . 4 × 10 - 8 J/line, respectively. Meanwhile, the linearity of the two versions are 99.74% and 99.99%, respectively.
Factor Structure Evaluation of the French Version of the Digital Natives Assessment Scale.
Wagner, Vincent; Acier, Didier
2017-03-01
"Digital natives" concept defines young adults particularly familiar with emerging technologies such as computers, smartphones, or Internet. This notion is still controversial and so far, the primary identifying criterion was to consider their date of birth. However, literature highlighted the need to describe specific characteristics. The purpose of this research was to evaluate the factor structure of a French version of the Digital Natives Assessment Scale (DNAS). The sample of this study includes 590 participants from a 6-week massive open online course and from Web sites, electronic forums, and social networks. The DNAS was translated in French and then back-translated to English. A principal component analysis with orthogonal rotation followed by a confirmatory factorial analysis showed that a 15-item four-correlated component model provided the best fit for the data of our sample. Factor structure of this French-translated version of the DNAS was rather similar than those found in earlier studies. This study provides evidence of the DNAS robustness through cross-cultural and cross-generational validation. The French version of the DNAS appears to be appropriate as a quick and effective questionnaire to assess digital natives. More studies are needed to better define further features of this particular group.
Using High Spatial Resolution Digital Imagery
2005-02-01
digital base maps were high resolution U.S. Geological Survey (USGS) Digital Orthophoto Quarter Quadrangles (DOQQ). The Root Mean Square Errors (RMSE...next step was to assign real world coordinates to the linear im- age. The mosaics were geometrically registered to the panchromatic orthophotos ...useable thematic map from high-resolution imagery. A more practical approach may be to divide the Refuge into a set of smaller areas, or tiles
Summary of the Validation of the Second Version of the Aster Gdem
NASA Astrophysics Data System (ADS)
Meyer, D. J.; Tachikawa, T.; Abrams, M.; Crippen, R.; Krieger, T.; Gesch, D.; Carabajal, C.
2012-07-01
On October 17, 2011, NASA and the Ministry of Economy, Trade and Industry (METI) of Japan released the second version of the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) Global Digital Elevation Model (GDEM) to users worldwide at no charge as a contribution to the Global Earth Observing System of Systems (GEOSS). The first version of the ASTER GDEM, released on June 29, 2009, was compiled from over 1.2 million scene-based DEMs covering land surfaces between 83°N and 83°S latitudes. The second version (GDEM2) incorporates 260,000 additional scenes to improve coverage, a smaller correlation kernel to yield higher spatial resolution, and improved water masking. As with GDEM1, US and Japanese partners collaborated to validate GDEM2. Its absolute accuracy was within -0.20 meters on average when compared against 18,000 geodetic control points over the conterminous US (CONUS), with an accuracy of 17 meters at the 95% confidence level. The Japan study noted the GDEM2 differed from the 10-meter national elevation grid by -0.7 meters over bare areas, and by 7.4 meters over forested areas. The CONUS study noted a similar result, with the GDEM2 determined to be about 8 meters above the 1 arc-second US National Elevation Database (NED) over most forested areas, and more than a meter below NED over bare areas. A global ICESat study found the GDEM2 to be on average within 3 meters of altimeter-derived control. The Japan study noted a horizontal displacement of 0.23 pixels in GDEM2. A study from the US National Geospatial Intelligence Agency also determined horizontal displacement and vertical accuracy as compared to the 1 arc-second Shuttle Radar Topography Mission DEM. US and Japanese studies estimated the horizontal resolution of the GDEM2 to be between 71 and 82 meters. Finally, the number of voids and artifacts noted in GDEM1 were substantially reduced in GDEM2.
Aitken, Douglas S.
1997-01-01
This Open-File report is a digital topographic map database. It contains a digital version of the 1970 U.S. Geological Survey topographic map of the San Francisco Bay Region (3 sheets), at a scale of 1:125,000. These ARC/INFO coverages are in vector format. The vectorization process has distorted characters representing letters and numbers, as well as some road and other symbols, making them difficult to read in some instances. This pamphlet serves to introduce and describe the digital data. There is no paper map included in the Open-File report. The content and character of the database and methods of obtaining it are described herein.
ERIC Educational Resources Information Center
Nielsen, Greg; Ferrara, Margaret M.
2014-01-01
According to many educators, textbooks will eventually be replaced by digital versions. Today's teachers, school administrators, and education policy makers are often digitally disconnected or at best digital immigrants, individuals who were born before the existence of digital technology and adopted it later in life. Unfortunately, when…
NASA Astrophysics Data System (ADS)
Caragiulo, P.; Dragone, A.; Markovic, B.; Herbst, R.; Nishimura, K.; Reese, B.; Herrmann, S.; Hart, P.; Blaj, G.; Segal, J.; Tomada, A.; Hasi, J.; Carini, G.; Kenney, C.; Haller, G.
2014-09-01
ePix100 is the first variant of a novel class of integrating pixel ASICs architectures optimized for the processing of signals in second generation LINAC Coherent Light Source (LCLS) X-Ray cameras. ePix100 is optimized for ultra-low noise application requiring high spatial resolution. ePix ASICs are based on a common platform composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog to digital converters per column. The ePix100 variant has 50μmx50μm pixels arranged in a 352x384 matrix, a resolution of 50e- r.m.s. and a signal range of 35fC (100 photons at 8keV). In its final version it will be able to sustain a frame rate of 1kHz. A first prototype has been fabricated and characterized and the measurement results are reported here.
NASA Technical Reports Server (NTRS)
Ambrosia, Vincent G.; Myers, Jeffrey S.; Ekstrand, Robert E.; Fitzgerald, Michael T.
1991-01-01
A simple method for enhancing the spatial and spectral resolution of disparate data sets is presented. Two data sets, digitized aerial photography at a nominal spatial resolution 3,7 meters and TMS digital data at 24.6 meters, were coregistered through a bilinear interpolation to solve the problem of blocky pixel groups resulting from rectification expansion. The two data sets were then subjected to intensity-saturation-hue (ISH) transformations in order to 'blend' the high-spatial-resolution (3.7 m) digitized RC-10 photography with the high spectral (12-bands) and lower spatial (24.6 m) resolution TMS digital data. The resultant merged products make it possible to perform large-scale mapping, ease photointerpretation, and can be derived for any of the 12 available TMS spectral bands.
A digital gigapixel large-format tile-scan camera.
Ben-Ezra, M
2011-01-01
Although the resolution of single-lens reflex (SLR) and medium-format digital cameras has increased in recent years, applications for cultural-heritage preservation and computational photography require even higher resolutions. Addressing this issue, a large-format cameras' large image planes can achieve very high resolution without compromising pixel size and thus can provide high-quality, high-resolution images.This digital large-format tile scan camera can acquire high-quality, high-resolution images of static scenes. It employs unique calibration techniques and a simple algorithm for focal-stack processing of very large images with significant magnification variations. The camera automatically collects overlapping focal stacks and processes them into a high-resolution, extended-depth-of-field image.
Design and performance of a custom ASIC digitizer for wire chamber readout in 65 nm CMOS technology
NASA Astrophysics Data System (ADS)
Lee, M. J.; Brown, D. N.; Chang, J. K.; Ding, D.; Gnani, D.; Grace, C. R.; Jones, J. A.; Kolomensky, Y. G.; von der Lippe, H.; Mcvittie, P. J.; Stettler, M. W.; Walder, J.-P.
2015-06-01
We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital Converters (TDCs), one 8-bit Analog-to-Digital Converter (ADC), a front-end preamplifier and shaper, plus digital and analog buffers that support a variety of digitization chains. The prototype has a multiplexed digital backend that executes a state machine, distributes control and timing signals, and buffers data for serial output. Laboratory bench tests measure the absolute TDC resolution between 74 ps and 480 ps, growing with the absolute delay, and a relative time resolution of 19 ps. Resolution outliers due to cross-talk between clock signals and supply or reference voltages are seen. After calibration, the ADC displays good linearity and noise performance, with an effective number of bits of 6.9. Under normal operating conditions the circuit consumes 32 mW per channel. Potential design improvements to address the resolution drift and tails are discussed.
Stoeser, Douglas B.; Green, Gregory N.; Morath, Laurie C.; Heran, William D.; Wilson, Anna B.; Moore, David W.; Van Gosen, Bradley S.
2005-01-01
The growth in the use of Geographic Information Systems (GIS) has highlighted the need for regional and national digital geologic maps attributed with age and lithology information. Such maps can be conveniently used to generate derivative maps for purposes including mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This Open-File Report is a preliminary version of part of a series of integrated state geologic map databases that cover the entire United States. The only national-scale digital geologic maps that portray most or all of the United States for the conterminous U.S. are the digital version of the King and Beikman (1974a, b) map at a scale of 1:2,500,000, as digitized by Schruben and others (1994) and the digital version of the Geologic Map of North America (Reed and others, 2005a, b) compiled at a scale of 1:5,000,000 which is currently being prepared by the U.S. Geological Survey. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. In a few cases, new digital compilations were prepared (e.g. OH, SC, SD) or existing paper maps were digitized (e.g. KY, TX). For Alaska and Hawaii, new regional maps are being compiled and ultimately new state maps will be produced. The digital geologic maps are presented in standardized formats as ARC/INFO (.e00) export files and as ArcView shape (.shp) files. Accompanying these spatial databases are a set of five supplemental data tables that relate the map units to detailed lithologic and age information. The maps for the CONUS have been fitted to a common set of state boundaries based on the 1:100,000 topographic map series of the United States Geological Survey (USGS). When the individual state maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps. No attempt has been made to reconcile differences in mapped geology across state lines. This is the first version of this product and it will be subsequently updated to include four additional states (North Dakota, South Dakota, Nebraska, and Iowa)
A microprocessor based anti-aliasing filter for a PCM system
NASA Technical Reports Server (NTRS)
Morrow, D. C.; Sandlin, D. R.
1984-01-01
Described is the design and evaluation of a microprocessor based digital filter. The filter was made to investigate the feasibility of a digital replacement for the analog pre-sampling filters used in telemetry systems at the NASA Ames-Dryden Flight Research Facility (DFRF). The digital filter will utilize an Intel 2920 Analog Signal Processor (ASP) chip. Testing includes measurements of: (1) the filter frequency response and, (2) the filter signal resolution. The evaluation of the digital filter was made on the basis of circuit size, projected environmental stability and filter resolution. The 2920 based digital filter was found to meet or exceed the pre-sampling filter specifications for limited signal resolution applications.
Geologic map of Yosemite National Park and vicinity, California
Huber, N.K.; Bateman, P.C.; Wahrhaftig, Clyde
1989-01-01
This digital map database represents the general distribution of bedrock and surficial deposits of the Yosemite National Park vicinity. It was produced directly from the file used to create the print version in 1989. The Yosemite National Park region is comprised of portions of 15 7.5 minute quadrangles. The original publication of the map in 1989 included the map, described map units and provided correlations, as well as a geologic summary and references, all on the same sheet. The database delineates map units that are identified by general age and lithology following the stratigraphic nomenclature of the U.S. Geological Survey. The scale of the source maps limits the spatial resolution (scale) of the database to 1:125,000 or smaller.
NASA Astrophysics Data System (ADS)
Escoffier, R. P.; Comoretto, G.; Webber, J. C.; Baudry, A.; Broadwell, C. M.; Greenberg, J. H.; Treacy, R. R.; Cais, P.; Quertier, B.; Camino, P.; Bos, A.; Gunst, A. W.
2007-02-01
Aims: The Atacama Large Millimeter Array (ALMA) is an international astronomy facility to be used for detecting and imaging all types of astronomical sources at millimeter and submillimeter wavelengths at a 5000-m elevation site in the Atacama Desert of Chile. Our main aims are: describe the correlator sub-system which is that part of the ALMA system that combines the signal from up to 64 remote individual radio antennas and forms them into a single instrument; emphasize the high spectral resolution and the configuration flexibility available with the ALMA correlator. Methods: The main digital signal processing features and a block diagram of the correlator being constructed for the ALMA radio astronomy observatory are presented. Tables of observing modes and spectral resolutions offered by the correlator system are given together with some examples of multi-resolution spectral modes. Results: The correlator is delivered by quadrants and the first quadrant is being tested while most of the other printed circuit cards required by the system have been produced. In its final version the ALMA correlator will process the outputs of up to 64 antennas using an instantaneous bandwidth of 8 GHz in each of two polarizations per antenna. In the frequency division mode, unrivalled spectral flexibility together with very high resolution (3.8 kHz) and up to 8192 spectral points are achieved. In the time division mode high time resolution is available with minimum data dump rates of 16 ms for all cross-products.
Update of the ACR-NEMA digital imaging and communications in medicine standard
NASA Astrophysics Data System (ADS)
Best, David E.; Horii, Steven C.; Bennett, William C.; Parisot, Charles R.
1992-07-01
The American College of Radiology and the National Electrical Manufacturers Association published the ACR-NEMA Digital Imaging and Communications Standard in 1985. Implementations are just now becoming available. Working groups of the committee have been very active. An expanded version of the Standard was published in 1988 and in a third version, to be known as Digital Imaging and Communications in Medicine (DICOM), is being prepared for publication in 1992. This paper briefly reviews the history of the Standard, describes the participation of the committee in international radiological imaging standards activities, and outlines the extensions planned for the DICOM Standard.
Marković, Bojan; Ignjatović, Janko; Vujadinović, Mirjana; Savić, Vedrana; Vladimirov, Sote; Karljiković-Rajić, Katarina
2015-01-01
Inter-laboratory verification of European pharmacopoeia (EP) monograph on derivative spectrophotometry (DS) method and its application for chitosan hydrochloride was carried out on two generation of instruments (earlier GBC Cintra 20 and current technology TS Evolution 300). Instruments operate with different versions of Savitzky-Golay algorithm and modes of generating digital derivative spectra. For resolution power parameter, defined as the amplitude ratio A/B in DS method EP monograph, comparable results were obtained only with algorithm's parameters smoothing points (SP) 7 and the 2nd degree polynomial and those provided corresponding data with other two modes on TS Evolution 300 Medium digital indirect and Medium digital direct. Using quoted algorithm's parameters, the differences in percentages between the amplitude ratio A/B averages, were within accepted criteria (±3%) for assay of drug product for method transfer. The deviation of 1.76% for the degree of deacetylation assessment of chitosan hydrochloride, determined on two instruments, (amplitude (1)D202; the 2nd degree polynomial and SP 9 in Savitzky-Golay algorithm), was acceptable, since it was within allowed criteria (±2%) for assay deviation of drug substance, for method transfer in pharmaceutical analyses. Copyright © 2015 Elsevier B.V. All rights reserved.
Resolution Properties Of A Computed Radiographic System
NASA Astrophysics Data System (ADS)
Fujita, Hiroshi; Morishita, Junji; Ueda, Katsuhiko; Tsai, Du Y.; Ohtsuka, Akiyoshi; Fujikawa, Tsuyoshi
1989-05-01
The analysis of spatial-resolution properties in terms of the modulation transfer function (MTF) has been presented in a computed radiographic (CR) system (FCR-101) with the photostimulable-phosphor plate (imaging plate, IP). The newly devised method of determining the presampling MTF which includes the x-ray detector (IP) unsharpness and the unsharpness of the sampling aperture is described in which an image of a slightly-angulated lead slit relative to a horizontal or vertical direction is employed. The IP MTFs as an analog MTF in the system, the presampling MTFs for different types of IPs, different sampling distances, different versions of IPs, simultaneous multisection tomography and magnification radiography, and the laser-printer MTFs as display MTF are measured and shown. The effective sampling aperture MTFs calculated indicate that the noticeable degradation of resolution occurs at the stage of image data sampling. The usefulness of the magnification technique for mammography and bone radiography is demonstrated. It is shown that both of the digital MTF and the overall MTF are difficult to use for general purpose due to the aliasing artifacts. The effect of glare on the contrast is also characterized by lead-disk method. The glare fraction is found to be approximately 6.5%.
High-Resolution Digital Terrain Models of the Sacramento/San Joaquin Delta Region, California
Coons, Tom; Soulard, Christopher E.; Knowles, Noah
2008-01-01
The U.S. Geological Survey (USGS) Western Region Geographic Science Center, in conjunction with the USGS Water Resources Western Branch of Regional Research, has developed a high-resolution elevation dataset covering the Sacramento/San Joaquin Delta region of California. The elevation data were compiled photogrammically from aerial photography (May 2002) with a scale of 1:15,000. The resulting dataset has a 10-meter horizontal resolution grid of elevation values. The vertical accuracy was determined to be 1 meter. Two versions of the elevation data are available: the first dataset has all water coded as zero, whereas the second dataset has bathymetry data merged with the elevation data. The projection of both datasets is set to UTM Zone 10, NAD 1983. The elevation data are clipped into files that spatially approximate 7.5-minute USGS quadrangles, with about 100 meters of overlap to facilitate combining the files into larger regions without data gaps. The files are named after the 7.5-minute USGS quadrangles that cover the same general spatial extent. File names that include a suffix (_b) indicate that the bathymetry data are included (for example, sac_east versus sac_east_b). These files are provided in ESRI Grid format.
Lunar Polar Illumination for Power Analysis
NASA Technical Reports Server (NTRS)
Fincannon, James
2008-01-01
This paper presents illumination analyses using the latest Earth-based radar digital elevation model (DEM) of the lunar south pole and an independently developed analytical tool. These results enable the optimum sizing of solar/energy storage lunar surface power systems since they quantify the timing and durations of illuminated and shadowed periods. Filtering and manual editing of the DEM based on comparisons with independent imagery were performed and a reduced resolution version of the DEM was produced to reduce the analysis time. A comparison of the DEM with lunar limb imagery was performed in order to validate the absolute heights over the polar latitude range, the accuracy of which affects the impact of long range, shadow-casting terrain. Average illumination and energy storage duration maps of the south pole region are provided for the worst and best case lunar day using the reduced resolution DEM. Average illumination fractions and energy storage durations are presented for candidate low energy storage duration south pole sites. The best site identified using the reduced resolution DEM required a 62 hr energy storage duration using a fast recharge power system. Solar and horizon terrain elevations as well as illumination fraction profiles are presented for the best identified site and the data for both the reduced resolution and high resolution DEMs compared. High resolution maps for three low energy storage duration areas are presented showing energy storage duration for the worst case lunar day, surface height, and maximum absolute surface slope.
Artifacts in Digital Coincidence Timing
Moses, W. W.; Peng, Q.
2014-01-01
Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into a time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator. All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e., the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the “optimal” method. The purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization. PMID:25321885
Artifacts in digital coincidence timing
Moses, W. W.; Peng, Q.
2014-10-16
Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into amore » time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator.All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e. the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the 'optimal' method. In conclusion, the purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization.« less
Artifacts in digital coincidence timing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moses, W. W.; Peng, Q.
Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into amore » time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator.All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e. the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the 'optimal' method. In conclusion, the purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization.« less
Moderate Resolution Imaging Spectroradiometer (MODIS) Overview
,
2008-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) is an instrument that collects remotely sensed data used by scientists for monitoring, modeling, and assessing the effects of natural processes and human actions on the Earth's surface. The continual calibration of the MODIS instruments, the refinement of algorithms used to create higher-level products, and the ongoing product validation make MODIS images a valuable time series (2000-present) of geophysical and biophysical land-surface measurements. Carried on two National Aeronautics and Space Administration (NASA) Earth Observing System (EOS) satellites, MODIS acquires morning (EOS-Terra) and afternoon (EOS-Aqua) views almost daily. Terra data acquisitions began in February 2000 and Aqua data acquisitions began in July 2002. Land data are generated only as higher-level products, removing the burden of common types of data processing from the user community. MODIS-based products describing ecological dynamics, radiation budget, and land cover are projected onto a sinusoidal mapping grid and distributed as 10- by 10-degree tiles at 250-, 500-, or 1,000-meter spatial resolution. Some products are also created on a 0.05-degree geographic grid to support climate modeling studies. All MODIS products are distributed in the Hierarchical Data Format-Earth Observing System (HDF-EOS) file format and are available through file transfer protocol (FTP) or on digital video disc (DVD) media. Versions 4 and 5 of MODIS land data products are currently available and represent 'validated' collections defined in stages of accuracy that are based on the number of field sites and time periods for which the products have been validated. Version 5 collections incorporate the longest time series of both Terra and Aqua MODIS data products.
An Integrated Bathymetric and Topographic Digital Terrain Model of the Canadian Arctic Archipelago
NASA Astrophysics Data System (ADS)
Alm, G.; Macnab, R.; Jakobsson, M.; Kleman, J.; McCracken, M.
2002-12-01
Currently, the International Bathymetric Chart of the Arctic Ocean (IBCAO) [Jakobsson et al. 2000], contains the most up-to-date digital bathymetric model of the entire Canadian Arctic Archipelago. IBCAO is a seamless bathymetric/topographic Digital Terrain Model (DTM) that incorporates three primary data sets: all available bathymetric data at the time of compilation; the US Geological Survey GTOPO30 topographic data; and the World Vector Shoreline for coastline representation. The horizontal grid cell size is 2.5 x 2.5 km on a Polar Stereographic projection, which is adequate for regional visualization and analysis, but which may not be sufficient for certain geoscientific and oceanographic applications. However, the database that was constructed during the IBCAO project holds bathymetric data of a high quality throughout most of the Canadian Arctic Archipelago, justifying a compilation resolution that is better than 2.5 x 2.5 km. This data is primarily from historical hydrographic surveys that were carried out by the Canadian Hydrographic Survey (CHS). The construction of a higher resolution bathymetry/topography DTM of the Canadian Arctic Archipelago (complete with an error estimation of interpolated grid cells) requires a consideration of historical metadata which contains detailed descriptions of horizontal and vertical datums, positioning systems, and the depth sounding systems that were deployed during individual surveys. A significant portion of this metadata does not exist in digital form; it was not available during the IBCAO compilation, although due to the relatively low resolution of the original DTM (2.5 x 2.5 km), its absence was considered a lesser problem. We have performed "data detective" work and have extracted some of the more crucial metadata from CHS archives and are thus able to present a preliminary version of a seamless Digital Terrain Model of the Canadian Arctic Archipelago. This represents a significant improvement over the original IBCAO DTM in this area. The use of a merged seamless bathymetry/topography model substantially facilitates the overlay and incorporation of other spatially referenced geological and geophysical datasets. For example, one intended use of the model is to merge the results from the mapping of regional glacial morphology features, in order to further address the glacial history of the region. Jakobsson, M., Cherkis, N., Woodward, J., Coakley, B., and Macnab, R., 2000, A new grid of Arctic bathymetry: A significant resource for scientists and mapmakers, EOS Transactions, American Geophysical Union, v. 81, no. 9, p. 89, 93, 96.
FGDC Digital Cartographic Standard for Geologic Map Symbolization (PostScript Implementation)
,
2006-01-01
PLEASE NOTE: This now-approved 'FGDC Digital Cartographic Standard for Geologic Map Symbolization (PostScript Implementation)' officially supercedes its earlier (2000) Public Review Draft version (see 'Earlier Versions of the Standard' below). In August 2006, the Digital Cartographic Standard for Geologic Map Symbolization was officially endorsed by the Federal Geographic Data Committee (FGDC) as the national standard for the digital cartographic representation of geologic map features (FGDC Document Number FGDC-STD-013-2006). Presented herein is the PostScript Implementation of the standard, which will enable users to directly apply the symbols in the standard to geologic maps and illustrations prepared in desktop illustration and (or) publishing software. The FGDC Digital Cartographic Standard for Geologic Map Symbolization contains descriptions, examples, cartographic specifications, and notes on usage for a wide variety of symbols that may be used on typical, general-purpose geologic maps and related products such as cross sections. The standard also can be used for different kinds of special-purpose or derivative map products and databases that may be focused on a specific geoscience topic (for example, slope stability) or class of features (for example, a fault map). The standard is scale-independent, meaning that the symbols are appropriate for use with geologic mapping compiled or published at any scale. It will be useful to anyone who either produces or uses geologic map information, whether in analog or digital form. Please be aware that this standard is not intended to be used inflexibly or in a manner that will limit one's ability to communicate the observations and interpretations gained from geologic mapping. In certain situations, a symbol or its usage might need to be modified in order to better represent a particular feature on a geologic map or cross section. This standard allows the use of any symbol that doesn't conflict with others in the standard, provided that it is clearly explained on the map and in the database. In addition, modifying the size, color, and (or) lineweight of an existing symbol to suit the needs of a particular map or output device also is permitted, provided that the modified symbol's appearance is not too similar to another symbol on the map. Be aware, however, that reducing lineweights below .125 mm (.005 inch) may cause symbols to plot incorrectly if output at higher resolutions (1800 dpi or higher). For guidelines on symbol usage, as well as on color design and map labeling, please refer to the standard's introductory text. Also found there are informational sections covering concepts of geologic mapping and some definitions of geologic map features, as well as sections on the newly defined concepts and terminology for the scientific confidence and locational accuracy of geologic map features. More information on both the past development and the future maintenance of the FGDC Digital Cartographic Standard for Geologic Map Symbolization can be found at the FGDC Geologic Data Subcommittee website (http://ngmdb.usgs.gov/fgdc_gds/). Earlier Versions of the Standard
Advanced Receiver For Phase-Shift-Keyed Signals
NASA Technical Reports Server (NTRS)
Hinedi, Sami M.
1992-01-01
ARX II is second "breadboard" version of advanced receiver, a hybrid digital/analog receiving subsystem, extracting symbols and Doppler shifts from weak phase-shift-keyed signals. Useful in terrestrial digital communication systems.
Technical note: Signal resolution increase and noise reduction in a CCD digitizer.
González, A; Martínez, J A; Tobarra, B
2004-03-01
Increasing output resolution is assumed to improve noise characteristics of a CCD digitizer. In this work, however, we have found that as the quantization step becomes lower than the analog noise (present in the signal before its conversion to digital) the noise reduction becomes significantly lower than expected. That is the case for values of sigma(an)/delta larger than 0.6, where sigma(an) is the standard deviation of the analog noise and delta is the quantization step. The procedure is applied to a commercially available CCD digitizer, and noise reduction by means of signal resolution increase is compared to that obtained by low pass filtering.
Developing a digital learning version of a mentorship training programme.
Casey, Debbie; Clark, Liz; Gould, Kathryn
2018-01-25
This article describes the experience of one university team in developing, delivering and evaluating an online Nursing and Midwifery Council-approved mentorship programme for nurses and midwives who support pre-registration students in practice. Although the authors are confident of the quality of the educational provision, this article does not discuss this programme as an exemplar of best practice, but aims to share the learning gained from the experience of introducing a digital learning version of a mentorship course.
Simple algorithms for digital pulse-shape discrimination with liquid scintillation detectors
NASA Astrophysics Data System (ADS)
Alharbi, T.
2015-01-01
The development of compact, battery-powered digital liquid scintillation neutron detection systems for field applications requires digital pulse processing (DPP) algorithms with minimum computational overhead. To meet this demand, two DPP algorithms for the discrimination of neutron and γ-rays with liquid scintillation detectors were developed and examined by using a NE213 liquid scintillation detector in a mixed radiation field. The first algorithm is based on the relation between the amplitude of a current pulse at the output of a photomultiplier tube and the amount of charge contained in the pulse. A figure-of-merit (FOM) value of 0.98 with 450 keVee (electron equivalent energy) energy threshold was achieved with this method when pulses were sampled at 250 MSample/s and with 8-bit resolution. Compared to the similar method of charge-comparison this method requires only a single integration window, thereby reducing the amount of computations by approximately 40%. The second approach is a digital version of the trailing-edge constant-fraction discrimination method. A FOM value of 0.84 with an energy threshold of 450 keVee was achieved with this method. In comparison with the similar method of rise-time discrimination this method requires a single time pick-off, thereby reducing the amount of computations by approximately 50%. The algorithms described in this work are useful for developing portable detection systems for applications such as homeland security, radiation dosimetry and environmental monitoring.
A high-resolution time-to-digital converter using a three-level resolution
NASA Astrophysics Data System (ADS)
Dehghani, Asma; Saneei, Mohsen; Mahani, Ali
2016-08-01
In this article, a three-level resolution Vernier delay line time-to-digital converter (TDC) was proposed. The proposed TDC core was based on the pseudo-differential digital architecture that made it insensitive to nMOS and pMOS transistor mismatches. It also employed a Vernier delay line (VDL) in conjunction with an asynchronous read-out circuitry. The time interval resolution was equal to the difference of delay between buffers of upper and lower chains. Then, via the extra chain included in the lower delay line, resolution was controlled and power consumption was reduced. This method led to high resolution and low power consumption. The measurement results of TDC showed a resolution of 4.5 ps, 12-bit output dynamic range, and integral nonlinearity of 1.5 least significant bits. This TDC achieved the consumption of 68.43 µW from 1.1-V supply.
NASA Astrophysics Data System (ADS)
MacMahon, Heber; Vyborny, Carl; Powell, Gregory; Doi, Kunio; Metz, Charles E.
1984-08-01
In digital radiography the pixel size used determines the potential spatial resolution of the system. The need for spatial resolution varies depending on the subject matter imaged. In many areas, including the chest, the minimum spatial resolution requirements have not been determined. Sarcoidosis is a disease which frequently causes subtle interstitial infiltrates in the lungs. As the initial step in an investigation designed to determine the minimum pixel size required in digital chest radiographic systems, we have studied 1 mm pixel digitized images on patients with early pulmonary sarcoidosis. The results of this preliminary study suggest that neither mild interstitial pulmonary infiltrates nor other abnormalities such as pneumothoraces may be detected reliably with 1 mm pixel digital images.
Microdome-gooved Gd(2)O(2)S:Tb scintillator for flexible and high resolution digital radiography.
Jung, Phill Gu; Lee, Chi Hoon; Bae, Kong Myeong; Lee, Jae Min; Lee, Sang Min; Lim, Chang Hwy; Yun, Seungman; Kim, Ho Kyung; Ko, Jong Soo
2010-07-05
A flexible microdome-grooved Gd(2)O(2)S:Tb scintillator is simulated, fabricated, and characterized for digital radiography applications. According to Monte Carlo simulation results, the dome-grooved structure has a high spatial resolution, which is verified by X-ray image performance of the scintillator. The proposed scintillator has lower X-ray sensitivity than a nonstructured scintillator but almost two times higher spatial resolution at high spatial frequency. Through evaluation of the X-ray performance of the fabricated scintillators, we confirm that the microdome-grooved scintillator can be applied to next-generation flexible digital radiography systems requiring high spatial resolution.
TimeSet: A computer program that accesses five atomic time services on two continents
NASA Technical Reports Server (NTRS)
Petrakis, P. L.
1993-01-01
TimeSet is a shareware program for accessing digital time services by telephone. At its initial release, it was capable of capturing time signals only from the U.S. Naval Observatory to set a computer's clock. Later the ability to synchronize with the National Institute of Standards and Technology was added. Now, in Version 7.10, TimeSet is able to access three additional telephone time services in Europe - in Sweden, Austria, and Italy - making a total of five official services addressable by the program. A companion program, TimeGen, allows yet another source of telephone time data strings for callers equipped with TimeSet version 7.10. TimeGen synthesizes UTC time data strings in the Naval Observatory's format from an accurately set and maintained DOS computer clock, and transmits them to callers. This allows an unlimited number of 'freelance' time generating stations to be created. Timesetting from TimeGen is made feasible by the advent of Becker's RighTime, a shareware program that learns the drift characteristics of a computer's clock and continuously applies a correction to keep it accurate, and also brings .01 second resolution to the DOS clock. With clock regulation by RighTime and periodic update calls by the TimeGen station to an official time source via TimeSet, TimeGen offers the same degree of accuracy within the resolution of the computer clock as any official atomic time source.
NASA Astrophysics Data System (ADS)
Karapetsas, Nikolaos; Skoulikaris, Charalampos; Katsogiannos, Fotis; Zalidis, George; Alexandridis, Thomas
2013-04-01
The use of satellite remote sensing products, such as Digital Elevation Models (DEMs), under specific computational interfaces of Geographic Information Systems (GIS) has fostered and facilitated the acquisition of data on specific hydrologic features, such as slope, flow direction and flow accumulation, which are crucial inputs to hydrology or hydraulic models at the river basin scale. However, even though DEMs of different resolution varying from a few km up to 20m are freely available for the European continent, these remotely sensed elevation data are rather coarse in cases where large flat areas are dominant inside a watershed, resulting in an unsatisfactory representation of the terrain characteristics. This scientific work aims at implementing a combing interpolation technique for the amelioration of the analysis of a DEM in order to be used as the input ground model to a hydraulic model for the assessment of potential flood events propagation in plains. More specifically, the second version of the ASTER Global Digital Elevation Model (GDEM2), which has an overall accuracy of around 20 meters, was interpolated with a vast number of aerial control points available from the Hellenic Mapping and Cadastral Organization (HMCO). The uncertainty that was inherent in both the available datasets (ASTER & HMCO) and the appearance of uncorrelated errors and artifacts was minimized by incorporating geostatistical filtering. The resolution of the produced DEM was approximately 10 meters and its validation was conducted with the use of an external dataset of 220 geodetic survey points. The derived DEM was then used as an input to the hydraulic model InfoWorks RS, whose operation is based on the relief characteristics contained in the ground model, for defining, in an automated way, the cross section parameters and simulating the flood spatial distribution. The plain of Serres, which is located in the downstream part of the Struma/Strymon transboundary river basin shared by Bulgaria and Greece, was selected as the case study area, because of its importance to the regional and national economy of Greece and because of the numerous flood events recorded in the past. The results of the simulation processing demonstrated the importance of high resolution relief models for estimating the potential flood hazard zones in order to mitigate the catastrophe caused, both in economic and environmental terms, by this type of extreme event.
Learner-Controlled Scaffolding Linked to Open-Ended Problems in a Digital Learning Environment
ERIC Educational Resources Information Center
Edson, Alden Jack
2017-01-01
This exploratory study reports on how students activated learner-controlled scaffolding and navigated through sequences of connected problems in a digital learning environment. A design experiment was completed to (re)design, iteratively develop, test, and evaluate a digital version of an instructional unit focusing on binomial distributions and…
Digital Reading Disposition Scale: A Study of Validity and Reliability
ERIC Educational Resources Information Center
Bulut, Berker; Karasakaloglu, Nuri
2018-01-01
In this study, "a Digital Reading Disposition Scale" was developed to determine undergraduate pre-service teacher students' dispositions towards digital reading, opposed to a preference for printed reading material. Initially, a 20-items trial version of the scale was administered to a total sample of N = 301 undergraduate pre-service…
Urban cover mapping using digital, high-resolution aerial imagery
Soojeong Myeong; David J. Nowak; Paul F. Hopkins; Robert H. Brock
2003-01-01
High-spatial resolution digital color-infrared aerial imagery of Syracuse, NY was analyzed to test methods for developing land cover classifications for an urban area. Five cover types were mapped: tree/shrub, grass/herbaceous, bare soil, water and impervious surface. Challenges in high-spatial resolution imagery such as shadow effect and similarity in spectral...
ERIC Educational Resources Information Center
Blanchi, Christophe; Petrone, Jason; Pinfield, Stephen; Suleman, Hussein; Fox, Edward A.; Bauer, Charly; Roddy, Carol Lynn
2001-01-01
Includes four articles that discuss a distributed architecture for managing metadata that promotes interoperability between digital libraries; the use of electronic print (e-print) by physicists; the development of digital libraries; and a collaborative project between two library consortia in Ohio to provide digital versions of Sanborn Fire…
NASA Technical Reports Server (NTRS)
Rider, D.; Blavier, J-F.; Cunningham, T.; Hancock, B.; Key, R.; Pannell, Z.; Sander, S.; Seshadri, S.; Sun, C.; Wrigley, C.
2011-01-01
Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.
Tabletop computed lighting for practical digital photography.
Mohan, Ankit; Bailey, Reynold; Waite, Jonathan; Tumblin, Jack; Grimm, Cindy; Bodenheimer, Bobby
2007-01-01
We apply simplified image-based lighting methods to reduce the equipment, cost, time, and specialized skills required for high-quality photographic lighting of desktop-sized static objects such as museum artifacts. We place the object and a computer-steered moving-head spotlight inside a simple foam-core enclosure and use a camera to record photos as the light scans the box interior. Optimization, guided by interactive user sketching, selects a small set of these photos whose weighted sum best matches the user-defined target sketch. Unlike previous image-based relighting efforts, our method requires only a single area light source, yet it can achieve high-resolution light positioning to avoid multiple sharp shadows. A reduced version uses only a handheld light and may be suitable for battery-powered field photography equipment that fits into a backpack.
Digital pulse processing for planar TlBr detectors
NASA Astrophysics Data System (ADS)
Nakhostin, M.; Hitomi, K.; Ishii, K.; Kikuchi, Y.
2010-04-01
We report on a digital pulse processing algorithm for correction of charge trapping in the planar TlBr detectors. The algorithm is performed on the signals digitized at the preamplifier stage. The algorithm is very simple and is implemented with little computational effort. By using a digitizer with a sampling rate of 250 MSample/s and 8 bit resolution, an energy resolution of 6.5% is achieved at 511 keV with a 0.7 mm thick detector.
NASA Astrophysics Data System (ADS)
Ahangarianabhari, Mahdi; Macera, Daniele; Bertuccio, Giuseppe; Malcovati, Piero; Grassi, Marco
2015-01-01
We present the design and the first experimental characterization of VEGA, an Application Specific Integrated Circuit (ASIC) designed to read out large area monolithic linear Silicon Drift Detectors (SDD's). VEGA consists of an analog and a digital/mixed-signal section to accomplish all the functionalities and specifications required for high resolution X-ray spectroscopy in the energy range between 500 eV and 50 keV. The analog section includes a charge sensitive preamplifier, a shaper with 3-bit digitally selectable shaping times from 1.6 μs to 6.6 μs and a peak stretcher/sample-and-hold stage. The digital/mixed-signal section includes an amplitude discriminator with coarse and fine threshold level setting, a peak discriminator and a logic circuit to fulfill pile-up rejection, signal sampling, trigger generation, channel reset and the preamplifier and discriminators disabling functionalities. A Serial Peripherical Interface (SPI) is integrated in VEGA for loading and storing all configuration parameters in an internal register within few microseconds. The VEGA ASIC has been designed and manufactured in 0.35 μm CMOS mixed-signal technology in single and 32 channel versions with dimensions of 200 μm×500 μm per channel. A minimum intrinsic Equivalent Noise Charge (ENC) of 12 electrons r.m.s. at 3.6 μs peaking time and room temperature is measured and the linearity error is between -0.9% and +0.6% in the whole input energy range. The total power consumption is 481 μW and 420 μW per channel for the single and 32 channels version, respectively. A comparison with other ASICs for X-ray SDD's shows that VEGA has a suitable low noise and offers high functionality as ADC-ready signal processing but at a power consumption that is a factor of four lower than other similar existing ASICs.
Towards Meaningful Learning through Digital Video Supported, Case Based Teaching
ERIC Educational Resources Information Center
Hakkarainen, Paivi; Saarelainen, Tarja; Ruokamo, Heli
2007-01-01
This paper reports an action research case study in which a traditional lecture based, face to face "Network Management" course at the University of Lapland's Faculty of Social Sciences was developed into two different course versions resorting to case based teaching: a face to face version and an online version. In the face to face…
Shaping the Values of Youth: Sunday School Books in 19th Century America
develop accessible digital/electronic collections, unfortunately, not all are. The MSU Libraries are able to provide remediated, accessible versions of digital/electronic library documents to library users
A digital 3D atlas of the marmoset brain based on multi-modal MRI.
Liu, Cirong; Ye, Frank Q; Yen, Cecil Chern-Chyi; Newman, John D; Glen, Daniel; Leopold, David A; Silva, Afonso C
2018-04-01
The common marmoset (Callithrix jacchus) is a New-World monkey of growing interest in neuroscience. Magnetic resonance imaging (MRI) is an essential tool to unveil the anatomical and functional organization of the marmoset brain. To facilitate identification of regions of interest, it is desirable to register MR images to an atlas of the brain. However, currently available atlases of the marmoset brain are mainly based on 2D histological data, which are difficult to apply to 3D imaging techniques. Here, we constructed a 3D digital atlas based on high-resolution ex-vivo MRI images, including magnetization transfer ratio (a T1-like contrast), T2w images, and multi-shell diffusion MRI. Based on the multi-modal MRI images, we manually delineated 54 cortical areas and 16 subcortical regions on one hemisphere of the brain (the core version). The 54 cortical areas were merged into 13 larger cortical regions according to their locations to yield a coarse version of the atlas, and also parcellated into 106 sub-regions using a connectivity-based parcellation method to produce a refined atlas. Finally, we compared the new atlas set with existing histology atlases and demonstrated its applications in connectome studies, and in resting state and stimulus-based fMRI. The atlas set has been integrated into the widely-distributed neuroimaging data analysis software AFNI and SUMA, providing a readily usable multi-modal template space with multi-level anatomical labels (including labels from the Paxinos atlas) that can facilitate various neuroimaging studies of marmosets. Published by Elsevier Inc.
1994-03-14
Comanche VAX/i960 Ada Compiler System, Version 4.1.1 Host Computer System: Digital Local Area Network VAX Cluster executing on (2) MicroVAX 3100 Model 90...31 $MAX DIGITS 15 SmNx INT 2147483647 $MAX INT PLUS_1 2147483648 $MIN IN -2_147483648 A-3 MACR PARAMEERIS $NAME NO SUCH INTEGER TYPE $NAME LIST...nested generlcs are Supported and generics defined in libary units are pexitted. zt is not possible to pen ore a macro instantiation for a generic I
STIC3 - Silicon Photomultiplier Timing Chip with picosecond resolution
NASA Astrophysics Data System (ADS)
Stankova, Vera; Shen, Wei; Briggl, Konrad; Chen, Huangshan; Fischer, Peter; Gil, Alejandro; Harion, Tobias; Kiworra, Volker; Munwes, Yonathan; Ritzert, Michael; Schultz-Coulon, Hans-Christian
2015-07-01
The diagnostic of pancreas and prostate cancer is a challenging task due to the background noise coming from the closer organs. The EndoToFPET-US project aims to combine the synergy between metabolic and anatomical (ultrasound) image in order to improve the precision in the tumor localization. The goal of the project is to develop a Positron Emission Tomography (PET) system that provides a time-of-flight resolution of 200 ps FWHM for improving the signal to noise ratio and further to improve the medical image quality. In order to achieve this purpose an ASIC has been designed for very high timing resolution in time-of-flight (ToF) applications. In this paper we present the ASIC performance and the first characterization measurements with the 64-channels prototype version (STiC3). Measurements are performed with LYSO scintillator crystal and a Multi Pixel Photon Counter (MPPC). Measurements with the chip show an analog-front-end stage jitter of 35 ps for the first photo-electron equivalent charge and reach 18 ps for the third photo-electron. Coincidence time resolution (CTR) of 240 ps FWHM is measured with 3.1×3.1×15 mm3 LYSO crystal and 50 μm pixel pitch MPPC. Further optimization including the Time-to-Digital Converter (TDC) non-linearity corrections and setup fine tuning are ongoing for achieving the desired CTR of 200 ps FWHM.
Worl, R.G.; Johnson, K.M.
1995-01-01
The paper version of Map Showing Geologic Terranes of the Hailey 1x2 Quadrangle and the western part of the Idaho Falls 1x2 Quadrangle, south-central Idaho was compiled by Ron Worl and Kate Johnson in 1995. The plate was compiled on a 1:250,000 scale topographic base map. TechniGraphic System, Inc. of Fort Collins Colorado digitized this map under contract for N.Shock. G.Green edited and prepared the digital version for publication as a geographic information system database. The digital geologic map database can be queried in many ways to produce a variety of geologic maps.
Initial Data of Digital Correlation ECE with a Giga Hertz Sampling Digitizer
NASA Astrophysics Data System (ADS)
Tsuchiya, Hayato; Inagaki, Shigeru; Tokuzawa, Tokihiko; Nagayama, Yoshio
2015-03-01
The proposed Digital Correlation ECE (DCECE) technique is applied in Large Helical Device. DCECE is realized by the use of the Giga Hertz Sampling Digitizer. The waveform of intermediate frequency band of ECE, whose frequency is several giga hertz, can be discretized and saved directly. The discretized IF data can be used for the analysis of correlation ECE with arbitrary parameter of spatial resolution and temporal resolution. In this paper, the characteristic of DCECE and initial Data in LHD is introduced.
Reading across Mediums: Effects of Reading Digital and Print Texts on Comprehension and Calibration
ERIC Educational Resources Information Center
Singer, Lauren M.; Alexander, Patricia A.
2017-01-01
This study explored differences that might exist in comprehension when students read digital and print texts. Ninety undergraduates read both digital and print versions of newspaper articles and book excerpts on topics of childhood ailments. Prior to reading texts in counterbalanced order, topic knowledge was assessed and students were asked to…
NASA Astrophysics Data System (ADS)
Wu, Yichen; Zhang, Yibo; Luo, Wei; Ozcan, Aydogan
2017-03-01
Digital holographic on-chip microscopy achieves large space-bandwidth-products (e.g., >1 billion) by making use of pixel super-resolution techniques. To synthesize a digital holographic color image, one can take three sets of holograms representing the red (R), green (G) and blue (B) parts of the spectrum and digitally combine them to synthesize a color image. The data acquisition efficiency of this sequential illumination process can be improved by 3-fold using wavelength-multiplexed R, G and B illumination that simultaneously illuminates the sample, and using a Bayer color image sensor with known or calibrated transmission spectra to digitally demultiplex these three wavelength channels. This demultiplexing step is conventionally used with interpolation-based Bayer demosaicing methods. However, because the pixels of different color channels on a Bayer image sensor chip are not at the same physical location, conventional interpolation-based demosaicing process generates strong color artifacts, especially at rapidly oscillating hologram fringes, which become even more pronounced through digital wave propagation and phase retrieval processes. Here, we demonstrate that by merging the pixel super-resolution framework into the demultiplexing process, such color artifacts can be greatly suppressed. This novel technique, termed demosaiced pixel super-resolution (D-PSR) for digital holographic imaging, achieves very similar color imaging performance compared to conventional sequential R,G,B illumination, with 3-fold improvement in image acquisition time and data-efficiency. We successfully demonstrated the color imaging performance of this approach by imaging stained Pap smears. The D-PSR technique is broadly applicable to high-throughput, high-resolution digital holographic color microscopy techniques that can be used in resource-limited-settings and point-of-care offices.
NASA Astrophysics Data System (ADS)
Caragiulo, P.; Dragone, A.; Markovic, B.; Herbst, R.; Nishimura, K.; Reese, B.; Herrmann, S.; Hart, P.; Blaj, G.; Segal, J.; Tomada, A.; Hasi, J.; Carini, G.; Kenney, C.; Haller, G.
2015-05-01
ePix10k is a variant of a novel class of integrating pixel ASICs architectures optimized for the processing of signals in second generation LINAC Coherent Light Source (LCLS) X-Ray cameras. The ASIC is optimized for high dynamic range application requiring high spatial resolution and fast frame rates. ePix ASICs are based on a common platform composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog to digital converters per column. The ePix10k variant has 100um×100um pixels arranged in a 176×192 matrix, a resolution of 140e- r.m.s. and a signal range of 3.5pC (10k photons at 8keV). In its final version it will be able to sustain a frame rate of 2kHz. A first prototype has been fabricated and characterized. Performance in terms of noise, linearity, uniformity, cross-talk, together with preliminary measurements with bump bonded sensors are reported here.
NASA Technical Reports Server (NTRS)
Monroe, Ryan M.
2011-01-01
A family of state-of-the-art digital Fourier transform spectrometers has been developed, with a combination of high bandwidth and fine resolution unavailable elsewhere. Analog signals consisting of radiation emitted by constituents in planetary atmospheres or galactic sources are downconverted and subsequently digitized by a pair of interleaved Analog-to-Digital Converters, (ADC). This 6 Gsps (giga-sample per second) digital representation of the analog signal is then processed through an FPGA-based streaming Fast Fourier Transform (FFT), the key development described below. Digital spectrometers have many advantages over previously used analog spectrometers, especially in terms of accuracy and resolution, both of which are particularly important for the type of scientific questions to be addressed with next-generation radiometers. the implementation, results and underlying math for this spectrometer, as well as, potential for future extension to even higher bandwidth, resolution and channel orthogonality, needed to support proposed future advanced atmospheric science and radioastronomy, are discussed.
Wideband Spectroscopy: The Design and Implementation of a 3 GHz, 2048 Channel Digital Spectrometer
NASA Technical Reports Server (NTRS)
Monroe, Ryan M.
2011-01-01
A state-of-the-art digital Fourier Transform spectrometer has been developed, with a combination of high bandwidth and fine resolution unavailable elsewhere. Analog signals consisting of radiation emitted by constituents in planetary atmospheres or galactic sources are downconverted and subsequently digitized by a pair of interleaved Analog-to-Digital Converters (ADC). This 6 Gsps (giga sample per second) digital representation of the analog signal is then processed through an FPGA-based streaming Fast Fourier Transform (FFT), the key development described below. Digital spectrometers have many advantages over previously used analog spectrometers, especially in terms of accuracy and resolution, both of which are particularly important for the type of scientific questions to be addressed with next-generation radiometers. The implementation, results and underlying math for this spectrometer, as well as potential for future extension to even higher bandwidth, resolution and channel orthogonality, needed to support proposed future advanced atmospheric science and radioastronomy, are discussed.
A hybrid analog-digital phase-locked loop for frequency mode non-contact scanning probe microscopy.
Mehta, M M; Chandrasekhar, V
2014-01-01
Non-contact scanning probe microscopy (SPM) has developed into a powerful technique to image many different properties of samples. The conventional method involves monitoring the amplitude, phase, or frequency of a cantilever oscillating at or near its resonant frequency as it is scanned across the surface of a sample. For high Q factor cantilevers, monitoring the resonant frequency is the preferred method in order to obtain reasonable scan times. This can be done by using a phase-locked-loop (PLL). PLLs can be obtained as commercial integrated circuits, but these do not have the frequency resolution required for SPM. To increase the resolution, all-digital PLLs requiring sophisticated digital signal processors or field programmable gate arrays have also been implemented. We describe here a hybrid analog/digital PLL where most of the components are implemented using discrete analog integrated circuits, but the frequency resolution is provided by a direct digital synthesis chip controlled by a simple peripheral interface controller (PIC) microcontroller. The PLL has excellent frequency resolution and noise, and can be controlled and read by a computer via a universal serial bus connection.
A hybrid analog-digital phase-locked loop for frequency mode non-contact scanning probe microscopy
NASA Astrophysics Data System (ADS)
Mehta, M. M.; Chandrasekhar, V.
2014-01-01
Non-contact scanning probe microscopy (SPM) has developed into a powerful technique to image many different properties of samples. The conventional method involves monitoring the amplitude, phase, or frequency of a cantilever oscillating at or near its resonant frequency as it is scanned across the surface of a sample. For high Q factor cantilevers, monitoring the resonant frequency is the preferred method in order to obtain reasonable scan times. This can be done by using a phase-locked-loop (PLL). PLLs can be obtained as commercial integrated circuits, but these do not have the frequency resolution required for SPM. To increase the resolution, all-digital PLLs requiring sophisticated digital signal processors or field programmable gate arrays have also been implemented. We describe here a hybrid analog/digital PLL where most of the components are implemented using discrete analog integrated circuits, but the frequency resolution is provided by a direct digital synthesis chip controlled by a simple peripheral interface controller (PIC) microcontroller. The PLL has excellent frequency resolution and noise, and can be controlled and read by a computer via a universal serial bus connection.
A New Improved and Extended Version of the Multicell Bacterial Simulator gro.
Gutiérrez, Martín; Gregorio-Godoy, Paula; Pérez Del Pulgar, Guillermo; Muñoz, Luis E; Sáez, Sandra; Rodríguez-Patón, Alfonso
2017-08-18
gro is a cell programming language developed in Klavins Lab for simulating colony growth and cell-cell communication. It is used as a synthetic biology prototyping tool for simulating multicellular biocircuits and microbial consortia. In this work, we present several extensions made to gro that improve the performance of the simulator, make it easier to use, and provide new functionalities. The new version of gro is between 1 and 2 orders of magnitude faster than the original version. It is able to grow microbial colonies with up to 10 5 cells in less than 10 min. A new library, CellEngine, accelerates the resolution of spatial physical interactions between growing and dividing cells by implementing a new shoving algorithm. A genetic library, CellPro, based on Probabilistic Timed Automata, simulates gene expression dynamics using simplified and easy to compute digital proteins. We also propose a more convenient language specification layer, ProSpec, based on the idea that proteins drive cell behavior. CellNutrient, another library, implements Monod-based growth and nutrient uptake functionalities. The intercellular signaling management was improved and extended in a library called CellSignals. Finally, bacterial conjugation, another local cell-cell communication process, was added to the simulator. To show the versatility and potential outreach of this version of gro, we provide studies and novel examples ranging from synthetic biology to evolutionary microbiology. We believe that the upgrades implemented for gro have made it into a powerful and fast prototyping tool capable of simulating a large variety of systems and synthetic biology designs.
Method and Apparatus for Improving the Resolution of Digitally Sampled Analog Data
NASA Technical Reports Server (NTRS)
Liaghati, Amir L. (Inventor)
2017-01-01
A system and method is described for converting an analog signal into a digital signal. The gain and offset of an ADC is dynamically adjusted so that the N-bits of input data are assigned to a narrower channel instead of the entire input range of the ADC. This provides greater resolution in the range of interest without generating longer digital data strings.
Holm, Sven; Russell, Greg; Nourrit, Vincent; McLoughlin, Niall
2017-01-01
A database of retinal fundus images, the DR HAGIS database, is presented. This database consists of 39 high-resolution color fundus images obtained from a diabetic retinopathy screening program in the UK. The NHS screening program uses service providers that employ different fundus and digital cameras. This results in a range of different image sizes and resolutions. Furthermore, patients enrolled in such programs often display other comorbidities in addition to diabetes. Therefore, in an effort to replicate the normal range of images examined by grading experts during screening, the DR HAGIS database consists of images of varying image sizes and resolutions and four comorbidity subgroups: collectively defined as the diabetic retinopathy, hypertension, age-related macular degeneration, and Glaucoma image set (DR HAGIS). For each image, the vasculature has been manually segmented to provide a realistic set of images on which to test automatic vessel extraction algorithms. Modified versions of two previously published vessel extraction algorithms were applied to this database to provide some baseline measurements. A method based purely on the intensity of images pixels resulted in a mean segmentation accuracy of 95.83% ([Formula: see text]), whereas an algorithm based on Gabor filters generated an accuracy of 95.71% ([Formula: see text]).
Improved Remapping Processor For Digital Imagery
NASA Technical Reports Server (NTRS)
Fisher, Timothy E.
1991-01-01
Proposed digital image processor improved version of Programmable Remapper, which performs geometric and radiometric transformations on digital images. Features include overlapping and variably sized preimages. Overcomes some of limitations of image-warping circuit boards implementing only those geometric tranformations expressible in terms of polynomials of limited order. Also overcomes limitations of existing Programmable Remapper and made to perform transformations at video rate.
Brakebill, J.W.; Preston, S.D.
2003-01-01
The U.S. Geological Survey has developed a methodology for statistically relating nutrient sources and land-surface characteristics to nutrient loads of streams. The methodology is referred to as SPAtially Referenced Regressions On Watershed attributes (SPARROW), and relates measured stream nutrient loads to nutrient sources using nonlinear statistical regression models. A spatially detailed digital hydrologic network of stream reaches, stream-reach characteristics such as mean streamflow, water velocity, reach length, and travel time, and their associated watersheds supports the regression models. This network serves as the primary framework for spatially referencing potential nutrient source information such as atmospheric deposition, septic systems, point-sources, land use, land cover, and agricultural sources and land-surface characteristics such as land use, land cover, average-annual precipitation and temperature, slope, and soil permeability. In the Chesapeake Bay watershed that covers parts of Delaware, Maryland, Pennsylvania, New York, Virginia, West Virginia, and Washington D.C., SPARROW was used to generate models estimating loads of total nitrogen and total phosphorus representing 1987 and 1992 land-surface conditions. The 1987 models used a hydrologic network derived from an enhanced version of the U.S. Environmental Protection Agency's digital River Reach File, and course resolution Digital Elevation Models (DEMs). A new hydrologic network was created to support the 1992 models by generating stream reaches representing surface-water pathways defined by flow direction and flow accumulation algorithms from higher resolution DEMs. On a reach-by-reach basis, stream reach characteristics essential to the modeling were transferred to the newly generated pathways or reaches from the enhanced River Reach File used to support the 1987 models. To complete the new network, watersheds for each reach were generated using the direction of surface-water flow derived from the DEMs. This network improves upon existing digital stream data by increasing the level of spatial detail and providing consistency between the reach locations and topography. The hydrologic network also aids in illustrating the spatial patterns of predicted nutrient loads and sources contributed locally to each stream, and the percentages of nutrient load that reach Chesapeake Bay.
An analysis of a digital variant of the Trail Making Test using machine learning techniques.
Dahmen, Jessamyn; Cook, Diane; Fellows, Robert; Schmitter-Edgecombe, Maureen
2017-01-01
The goal of this work is to develop a digital version of a standard cognitive assessment, the Trail Making Test (TMT), and assess its utility. This paper introduces a novel digital version of the TMT and introduces a machine learning based approach to assess its capabilities. Using digital Trail Making Test (dTMT) data collected from (N = 54) older adult participants as feature sets, we use machine learning techniques to analyze the utility of the dTMT and evaluate the insights provided by the digital features. Predicted TMT scores correlate well with clinical digital test scores (r = 0.98) and paper time to completion scores (r = 0.65). Predicted TICS exhibited a small correlation with clinically derived TICS scores (r = 0.12 Part A, r = 0.10 Part B). Predicted FAB scores exhibited a small correlation with clinically derived FAB scores (r = 0.13 Part A, r = 0.29 for Part B). Digitally derived features were also used to predict diagnosis (AUC of 0.65). Our findings indicate that the dTMT is capable of measuring the same aspects of cognition as the paper-based TMT. Furthermore, the dTMT's additional data may be able to help monitor other cognitive processes not captured by the paper-based TMT alone.
Karell, Mara A; Langstaff, Helen K; Halazonetis, Demetrios J; Minghetti, Caterina; Frelat, Mélanie; Kranioti, Elena F
2016-09-01
The commingling of human remains often hinders forensic/physical anthropologists during the identification process, as there are limited methods to accurately sort these remains. This study investigates a new method for pair-matching, a common individualization technique, which uses digital three-dimensional models of bone: mesh-to-mesh value comparison (MVC). The MVC method digitally compares the entire three-dimensional geometry of two bones at once to produce a single value to indicate their similarity. Two different versions of this method, one manual and the other automated, were created and then tested for how well they accurately pair-matched humeri. Each version was assessed using sensitivity and specificity. The manual mesh-to-mesh value comparison method was 100 % sensitive and 100 % specific. The automated mesh-to-mesh value comparison method was 95 % sensitive and 60 % specific. Our results indicate that the mesh-to-mesh value comparison method overall is a powerful new tool for accurately pair-matching commingled skeletal elements, although the automated version still needs improvement.
Improved Feature Matching for Mobile Devices with IMU.
Masiero, Andrea; Vettore, Antonio
2016-08-05
Thanks to the recent diffusion of low-cost high-resolution digital cameras and to the development of mostly automated procedures for image-based 3D reconstruction, the popularity of photogrammetry for environment surveys is constantly increasing in the last years. Automatic feature matching is an important step in order to successfully complete the photogrammetric 3D reconstruction: this step is the fundamental basis for the subsequent estimation of the geometry of the scene. This paper reconsiders the feature matching problem when dealing with smart mobile devices (e.g., when using the standard camera embedded in a smartphone as imaging sensor). More specifically, this paper aims at exploiting the information on camera movements provided by the inertial navigation system (INS) in order to make the feature matching step more robust and, possibly, computationally more efficient. First, a revised version of the affine scale-invariant feature transform (ASIFT) is considered: this version reduces the computational complexity of the original ASIFT, while still ensuring an increase of correct feature matches with respect to the SIFT. Furthermore, a new two-step procedure for the estimation of the essential matrix E (and the camera pose) is proposed in order to increase its estimation robustness and computational efficiency.
NASA Astrophysics Data System (ADS)
Chen, Chun-Chi; Hwang, Chorng-Sii; Lin, You-Ting; Liu, Keng-Chih
2015-12-01
This paper presents an all-digital CMOS pulse-shrinking mechanism suitable for time-to-digital converters (TDCs). A simple MOS capacitor is used as a pulse-shrinking cell to perform time attenuation for time resolving. Compared with a previous pulse-shrinking mechanism, the proposed mechanism provides an appreciably improved temporal resolution with high linearity. Furthermore, the use of a binary-weighted pulse-shrinking unit with scaled MOS capacitors is proposed for achieving a programmable resolution. A TDC involving the proposed mechanism was fabricated using a TSMC (Taiwan Semiconductor Manufacturing Company) 0.18-μm CMOS process, and it has a small area of nearly 0.02 mm2 and an integral nonlinearity error of ±0.8 LSB for a resolution of 24 ps.
ERIC Educational Resources Information Center
Granger, Stewart; Dekkers, Makx; Weibel, Stuart L.; Kirriemuir, John; Lensch, Hendrik P. A.; Goesele, Michael; Seidel, Hans-Peter; Birmingham, William; Pardo, Bryan; Meek, Colin; Shifrin, Jonah; Goodvin, Renee; Lippy, Brooke
2002-01-01
One opinion piece and five articles in this issue discuss: digital preservation infrastructure; accomplishments and changes in the Dublin Core Metadata Initiative in 2001 and plans for 2002; video gaming and how it relates to digital libraries and learning technologies; overview of a music retrieval system; and the online version of the…
TADIR-production version: El-Op's high-resolution 480x4 TDI thermal imaging system
NASA Astrophysics Data System (ADS)
Sarusi, Gabby; Ziv, Natan; Zioni, O.; Gaber, J.; Shechterman, Mark S.; Lerner, M.
1999-07-01
Efforts invested at El-Op during the last four years have led to the development of TADIR - engineering model thermal imager, demonstrated in 1998, and eventually to the final production version of TADIR to be demonstrated in full operation during 1999. Both versions take advantage of the high resolution and high sensitivity obtained by the 480 X 4 TDI MCT detector as well as many more features implemented in the system to obtain a state of the art high- end thermal imager. The production version of TADIR uses a 480 X 6 TDI HgCdTe detector made by the SCD Israeli company. In this paper, we will present the main features of the production version of TADIR.
Long wavelength propagation capacity, version 1.1 (computer diskette)
NASA Astrophysics Data System (ADS)
1994-05-01
File Characteristics: software and data file. (72 files); ASCII character set. Physical Description: 2 computer diskettes; 3 1/2 in.; high density; 1.44 MB. System Requirements: PC compatible; Digital Equipment Corp. VMS; PKZIP (included on diskette). This report describes a revision of the Naval Command, Control and Ocean Surveillance Center RDT&E Division's Long Wavelength Propagation Capability (LWPC). The first version of this capability was a collection of separate FORTRAN programs linked together in operation by a command procedure written in an operating system unique to the Digital Equipment Corporation (Ferguson & Snyder, 1989a, b). A FORTRAN computer program named Long Wavelength Propagation Model (LWPM) was developed to replace the VMS control system (Ferguson & Snyder, 1990; Ferguson, 1990). This was designated version 1 (LWPC-1). This program implemented all the features of the original VMS plus a number of auxiliary programs that provided summaries of the files and graphical displays of the output files. This report describes a revision of the LWPC, designated version 1.1 (LWPC-1.1)
NASA Astrophysics Data System (ADS)
Tada, Tsutomu; Hitomi, Keitaro; Tanaka, Tomonobu; Wu, Yan; Kim, Seong-Yun; Yamazaki, Hiromichi; Ishii, Keizo
2011-05-01
Digital pulse processing and electronic noise analysis are proposed for improving energy resolution in planar thallium bromide (TlBr) detectors. An energy resolution of 5.8% FWHM at 662 keV was obtained from a 0.5 mm thick planar TlBr detector at room temperature using a digitizer with a sampling rate of 100 MS/s and 8 bit resolution. The electronic noise in the detector-preamplifier system was measured as a function of pulse shaping time in order to investigate the optimum shaping time for the detector. The depth of interaction (DOI) in TlBr detectors for incident gamma-rays was determined by taking the ratio of pulse heights for fast-shaped to slow-shaped signals. FWHM energy resolution of the detector was improved from 5.8% to 4.2% by implementing depth correction and by using the obtained optimum shaping time.
Subranging technique using superconducting technology
Gupta, Deepnarayan
2003-01-01
Subranging techniques using "digital SQUIDs" are used to design systems with large dynamic range, high resolution and large bandwidth. Analog-to-digital converters (ADCs) embodying the invention include a first SQUID based "coarse" resolution circuit and a second SQUID based "fine" resolution circuit to convert an analog input signal into "coarse" and "fine" digital signals for subsequent processing. In one embodiment, an ADC includes circuitry for supplying an analog input signal to an input coil having at least a first inductive section and a second inductive section. A first superconducting quantum interference device (SQUID) is coupled to the first inductive section and a second SQUID is coupled to the second inductive section. The first SQUID is designed to produce "coarse" (large amplitude, low resolution) output signals and the second SQUID is designed to produce "fine" (low amplitude, high resolution) output signals in response to the analog input signals.
Superresolved digital in-line holographic microscopy for high-resolution lensless biological imaging
NASA Astrophysics Data System (ADS)
Micó, Vicente; Zalevsky, Zeev
2010-07-01
Digital in-line holographic microscopy (DIHM) is a modern approach capable of achieving micron-range lateral and depth resolutions in three-dimensional imaging. DIHM in combination with numerical imaging reconstruction uses an extremely simplified setup while retaining the advantages provided by holography with enhanced capabilities derived from algorithmic digital processing. We introduce superresolved DIHM incoming from time and angular multiplexing of the sample spatial frequency information and yielding in the generation of a synthetic aperture (SA). The SA expands the cutoff frequency of the imaging system, allowing submicron resolutions in both transversal and axial directions. The proposed approach can be applied when imaging essentially transparent (low-concentration dilutions) and static (slow dynamics) samples. Validation of the method for both a synthetic object (U.S. Air Force resolution test) to quantify the resolution improvement and a biological specimen (sperm cells biosample) are reported showing the generation of high synthetic numerical aperture values working without lenses.
NASA Technical Reports Server (NTRS)
Sheridan, W. T.; Warren, W. H., Jr.
1981-01-01
The spectra described represent a subset comprising data for 60 O- and B-type stars. The tape contains data in the spectral region lamda lamda 1000-1450 A with a resolution of 0.2 A. The magnetic tape version of the data is described.
Copyright for Academics in the Digital Age
ERIC Educational Resources Information Center
Ramsey, Colin; McCaughey, Martha
2012-01-01
When faculty members consider copyright in the digital age, it is often in relation to things they can't (or shouldn't) do. For example, they can't have too much material placed in online reserve, they can't scan journal articles to create digital versions of what used to be called "course packs," and they can't post an excerpt from a work of…
ERIC Educational Resources Information Center
Hilton, John, III.
2010-01-01
Lack of access prevents many from benefiting from educational resources. Digital technologies now enable educational resources, such as books, to be openly available to those with access to the Internet. This study examined the financial viability of a religious publisher's putting free digital versions of eight of its books on the Internet. The…
Waveform digitization for high resolution timing detectors with silicon photomultipliers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ronzhin, A.; Albrow, M. G.; Los, S.
2012-03-01
The results of time resolution studies with silicon photomultipliers (SiPMs) read out with high bandwidth constant fraction discrimination electronics were presented earlier [1-3]. Here we describe the application of fast waveform digitization readout based on the DRS4 chip [4], a switched capacitor array (SCA) produced by the Paul Scherrer Institute, to further our goal of developing high time resolution detectors based on SiPMs. The influence of the SiPM signal shape on the time resolution was investigated. Different algorithms to obtain the best time resolution are described, and test beam results are presented.
Schruben, Paul G.; Arndt, Raymond E.; Bawiec, Walter J.
1998-01-01
This CD-ROM contains a digital version of the Geologic Map of the United States, originally published at a scale of 1:2,500,000 (King and Beikman, 1974b). It excludes Alaska and Hawaii. In addition to the graphical formats, the map key is included in ASCII text. A geographic information system (GIS) allows combining and overlaying of layers for analysis of spatial relations not readily apparent in the standard paper publication. This disc contains only geology. However, digital data on geology, geophysics, and geochemistry can be combined to create useful derivative products-- for example, see Phillips and others (1993). This CD-ROM contains a copy of the text and figures from Professional Paper 901 by King and Beikman (1974a). This text describes the historical background of the map, details of the compilation process, and limitations to interpretation. The digital version of the text can be searched for keywords or phrases.
Implementation of high-resolution time-to-digital converter in 8-bit microcontrollers.
Bengtsson, Lars E
2012-04-01
This paper will demonstrate how a time-to-digital converter (TDC) with sub-nanosecond resolution can be implemented into an 8-bit microcontroller using so called "direct" methods. This means that a TDC is created using only five bidirectional digital input-output-pins of a microcontroller and a few passive components (two resistors, a capacitor, and a diode). We will demonstrate how a TDC for the range 1-10 μs is implemented with 0.17 ns resolution. This work will also show how to linearize the output by combining look-up tables and interpolation. © 2012 American Institute of Physics
An 11-bit and 39 ps resolution time-to-digital converter for ADPLL in digital television
NASA Astrophysics Data System (ADS)
Liu, Wei; (Ruth) Li, Wei; Ren, P.; Lin, C. L.; Zhang, Shengdong; Wang, Yangyuan
2010-04-01
We propose and demonstrate an 11-bit time-to-digital converter (TDC) for all-digital phase-locked loops (ADPLLs) in digital television. The proposed TDC converts the width of the input pulse into digital output with the tap space of the outputs of a free-running ring oscillator (FRO) being the conversion resolution. The FRO is in a structure of coiled cell array and the TDC core is symmetrical in the input structure. This leads to equally spaced taps in the reference clocks and thereby a high TDC conversion linearity. The TDC is fabricated in 0.13 μm CMOS process and the chip area is 0.025 mm2. The measurement results show that the TDC has a conversion resolution of 39 ps at 1.2 V power supply and a 4.5 ns dead time in the 11-bits output case. Both the differential non-linearity (DNL) and integral non-linearity (INL) are below 0.5 LSB. The power consumption of the whole circuit is 4.2 mW.
The Navy’s Application of Ocean Forecasting to Decision Support
2014-09-01
Prediction Center (OPC) website for graphics or the National Operational Model Archive and Distribution System ( NOMADS ) for data files. Regional...inputs: » GLOBE = Global Land One-km Base Elevation » WVS = World Vector Shoreline » DBDB2 = Digital Bathymetry Data Base 2 minute resolution » DBDBV... Digital Bathymetry Data Base variable resolution Oceanography | Vol. 27, No.3130 Very High-Resolution Coastal Circulation Models Nearshore
KOLAM: a cross-platform architecture for scalable visualization and tracking in wide-area imagery
NASA Astrophysics Data System (ADS)
Fraser, Joshua; Haridas, Anoop; Seetharaman, Guna; Rao, Raghuveer M.; Palaniappan, Kannappan
2013-05-01
KOLAM is an open, cross-platform, interoperable, scalable and extensible framework supporting a novel multi- scale spatiotemporal dual-cache data structure for big data visualization and visual analytics. This paper focuses on the use of KOLAM for target tracking in high-resolution, high throughput wide format video also known as wide-area motion imagery (WAMI). It was originally developed for the interactive visualization of extremely large geospatial imagery of high spatial and spectral resolution. KOLAM is platform, operating system and (graphics) hardware independent, and supports embedded datasets scalable from hundreds of gigabytes to feasibly petabytes in size on clusters, workstations, desktops and mobile computers. In addition to rapid roam, zoom and hyper- jump spatial operations, a large number of simultaneously viewable embedded pyramid layers (also referred to as multiscale or sparse imagery), interactive colormap and histogram enhancement, spherical projection and terrain maps are supported. The KOLAM software architecture was extended to support airborne wide-area motion imagery by organizing spatiotemporal tiles in very large format video frames using a temporal cache of tiled pyramid cached data structures. The current version supports WAMI animation, fast intelligent inspection, trajectory visualization and target tracking (digital tagging); the latter by interfacing with external automatic tracking software. One of the critical needs for working with WAMI is a supervised tracking and visualization tool that allows analysts to digitally tag multiple targets, quickly review and correct tracking results and apply geospatial visual analytic tools on the generated trajectories. One-click manual tracking combined with multiple automated tracking algorithms are available to assist the analyst and increase human effectiveness.
NASA Technical Reports Server (NTRS)
Nelson, David L.; Diner, David J.; Thompson, Charles K.; Hall, Jeffrey R.; Rheingans, Brian E.; Garay, Michael J.; Mazzoni, Dominic
2010-01-01
MISR (Multi-angle Imaging SpectroRadiometer) INteractive eXplorer (MINX) is an interactive visualization program that allows a user to digitize smoke, dust, or volcanic plumes in MISR multiangle images, and automatically retrieve height and wind profiles associated with those plumes. This innovation can perform 9-camera animations of MISR level-1 radiance images to study the 3D relationships of clouds and plumes. MINX also enables archiving MISR aerosol properties and Moderate Resolution Imaging Spectroradiometer (MODIS) fire radiative power along with the heights and winds. It can correct geometric misregistration between cameras by correlating off-nadir camera scenes with corresponding nadir scenes and then warping the images to minimize the misregistration offsets. Plots of BRF (bidirectional reflectance factor) vs. camera angle for points clicked in an image can be displayed. Users get rapid access to map views of MISR path and orbit locations and overflight dates, and past or future orbits can be identified that pass over a specified location at a specified time. Single-camera, level-1 radiance data at 1,100- or 275- meter resolution can be quickly displayed in color using a browse option. This software determines the heights and motion vectors of features above the terrain with greater precision and coverage than previous methods, based on an algorithm that takes wind direction into consideration. Human interpreters can precisely identify plumes and their extent, and wind direction. Overposting of MODIS thermal anomaly data aids in the identification of smoke plumes. The software has been used to preserve graphical and textural versions of the digitized data in a Web-based database.
DeWitt, Nancy T.; Flocks, James G.; Reynolds, B.J.; Hansen, Mark
2012-01-01
The Gulf Islands National Seashore (GUIS) is composed of a series of barrier islands along the Mississippi - Alabama coastline. Historically these islands have undergone long-term shoreline change. The devastation of Hurricane Katrina in 2005 prompted questions about the stability of the barrier islands and their potential response to future storm impacts. Additionally, there was concern from the National Park Service (NPS) about the preservation of the historical Fort Massachusetts, located on West Ship Island. During the early 1900s, Ship Island was an individual island. In 1969 Hurricane Camille breached Ship Island, widening the cut and splitting it into what is now known as West Ship Island and East Ship Island. In July of 2007, the U.S. Geological Survey (USGS) was able to provide the NPS with a small bathymetric survey of Camille Cut using high-resolution single-beam bathymetry. This provided GUIS with a post-Katrina assessment of the bathymetry in Camille Cut and along the northern shoreline directly in front of Fort Massachusetts. Ultimately, this survey became an initial bathymetry dataset toward a larger USGS effort included in the Northern Gulf of Mexico (NGOM) Ecosystem Change and Hazard Susceptibility Project (http://ngom.usgs.gov/gomsc/mscip/). This report serves as an archive of the processed single-beam bathymetry. Data products herein include gridded and interpolated digital depth surfaces and x,y,z data products. Additional files include trackline maps, navigation files, geographic information system (GIS) files, Field Activity Collection System (FACS) logs, and formal Federal Geographic Data Committee (FGDC) metadata. Scanned images of the handwritten FACS logs and digital FACS logs are also provided as PDF files. Refer to the Acronyms page for description of acronyms and abbreviations used in this report or hold the cursor over an acronym for a pop-up explanation. The USGS St. Petersburg Coastal and Marine Science Center assigns a unique identifier to each cruise or field activity. For example, 07CCT01 tells us the data were collected in 2007 for the Coastal Change and Transport (CCT) study and the data were collected during the first (01) field activity for that project in that calendar year. Refer to http://walrus.wr.usgs.gov/infobank/programs/html/definition/activity.html for a detailed description of the method used to assign the field activity ID. Data were collected using a 26-foot (ft) Glacier Bay catamaran. The single-beam transducers were sled mounted on a rail attached between the catamaran hulls. Navigation was acquired using HYPACK, Inc., Hypack version 4.3a.7.1 and differentially corrected using land-based GPS stations. See the digital FACS equipment log for details about the acquisition equipment used. Raw datasets were stored digitally and processed systematically using NovAtel's Waypoint GrafNav version 7.6, SANDS version 3.7, and ESRI ArcGIS version 9.3.1. For more information on processing refer to the Equipment and Processing page.
Windprofiler optimization using digital deconvolution procedures
NASA Astrophysics Data System (ADS)
Hocking, W. K.; Hocking, A.; Hocking, D. G.; Garbanzo-Salas, M.
2014-10-01
Digital improvements to data acquisition procedures used for windprofiler radars have the potential for improving the height coverage at optimum resolution, and permit improved height resolution. A few newer systems already use this capability. Real-time deconvolution procedures offer even further optimization, and this has not been effectively employed in recent years. In this paper we demonstrate the advantages of combining these features, with particular emphasis on the advantages of real-time deconvolution. Using several multi-core CPUs, we have been able to achieve speeds of up to 40 GHz from a standard commercial motherboard, allowing data to be digitized and processed without the need for any type of hardware except for a transmitter (and associated drivers), a receiver and a digitizer. No Digital Signal Processor chips are needed, allowing great flexibility with analysis algorithms. By using deconvolution procedures, we have then been able to not only optimize height resolution, but also have been able to make advances in dealing with spectral contaminants like ground echoes and other near-zero-Hz spectral contamination. Our results also demonstrate the ability to produce fine-resolution measurements, revealing small-scale structures within the backscattered echoes that were previously not possible to see. Resolutions of 30 m are possible for VHF radars. Furthermore, our deconvolution technique allows the removal of range-aliasing effects in real time, a major bonus in many instances. Results are shown using new radars in Canada and Costa Rica.
[Improvement of Digital Capsule Endoscopy System and Image Interpolation].
Zhao, Shaopeng; Yan, Guozheng; Liu, Gang; Kuang, Shuai
2016-01-01
Traditional capsule image collects and transmits analog image, with weak anti-interference ability, low frame rate, low resolution. This paper presents a new digital image capsule, which collects and transmits digital image, with frame rate up to 30 frames/sec and pixels resolution of 400 x 400. The image is compressed in the capsule, and is transmitted to the outside of the capsule for decompression and interpolation. A new type of interpolation algorithm is proposed, which is based on the relationship between the image planes, to obtain higher quality colour images. capsule endoscopy, digital image, SCCB protocol, image interpolation
Link, P.K.; Mahoney, J.B.; Bruner, D.J.; Batatian, L.D.; Wilson, Eric; Williams, F.J.C.
1995-01-01
The paper version of the Geologic map of outcrop areas of sedimentary units in the eastern part of the Hailey 1x2 Quadrangle and part of the southern part of the Challis 1x2 Quadrangle, south-central Idaho was compiled by Paul Link and others in 1995. The plate was compiled on a 1:100,000 scale topographic base map. TechniGraphic System, Inc. of Fort Collins Colorado digitized this map under contract for N.Shock. G.Green edited and prepared the digital version for publication as a GIS database. The digital geologic map database can be queried in many ways to produce a variety of geologic maps.
Software Design Description for the HYbrid Coordinate Ocean Model (HYCOM), Version 2.2
2009-02-12
scalars. J. Phys. Oceanogr. 32: 240–264. Carnes, M., (2002). Data base description for the Generalized Digital Environmental Model ( GDEM -V) (U...Direction FCT Flux-Corrected Transport scheme GDEM Generalized Digital Environmental Model GISS NASA Goddard Institute for Space Studies GRD
USDA-ARS?s Scientific Manuscript database
Ultra high resolution digital aerial photography has great potential to complement or replace ground measurements of vegetation cover for rangeland monitoring and assessment. We investigated object-based image analysis (OBIA) techniques for classifying vegetation in southwestern U.S. arid rangelands...
Incorporating digital imaging into dental hygiene practice.
Saxe, M J; West, D J
1997-01-01
The objective of this paper is to describe digital imaging technology: available modalities, scientific imaging process, advantages and limitations, and applications to dental hygiene practice. Advances in technology have created innovative imaging modalities for intraoral radiography that eliminate film as the traditional image receptor. Digital imaging generates instantaneous radiographic images on a display monitor following exposure. Advantages include lower patient exposure per image and elimination of film processing. Digital imaging enhances diagnostic capabilities and, therefore, treatment decisions by the oral healthcare provider. Utilization of digital imaging technology for intraoral radiography will advance the practice of dental hygiene. Although spatial resolution is inferior to conventional film, digital imaging provides adequate resolution to diagnose oral diseases. Dental hygienists must evaluate new technologies in radiography to continue providing quality care while reducing patient exposure to ionizing radiation.
Simulation of modern climate with the new version of the INM RAS climate model
NASA Astrophysics Data System (ADS)
Volodin, E. M.; Mortikov, E. V.; Kostrykin, S. V.; Galin, V. Ya.; Lykosov, V. N.; Gritsun, A. S.; Diansky, N. A.; Gusev, A. V.; Yakovlev, N. G.
2017-03-01
The INMCM5.0 numerical model of the Earth's climate system is presented, which is an evolution from the previous version, INMCM4.0. A higher vertical resolution for the stratosphere is applied in the atmospheric block. Also, we raised the upper boundary of the calculating area, added the aerosol block, modified parameterization of clouds and condensation, and increased the horizontal resolution in the ocean block. The program implementation of the model was also updated. We consider the simulation of the current climate using the new version of the model. Attention is focused on reducing systematic errors as compared to the previous version, reproducing phenomena that could not be simulated correctly in the previous version, and modeling the problems that remain unresolved.
NASA Astrophysics Data System (ADS)
Timmermann, Ralph; Schaffer, Janin
2016-04-01
The RTopo-1 data set of Antarctic ice sheet/shelf geometry and global ocean bathymetry has proven useful not only for modelling studies of ice-ocean interaction in the southern hemisphere. Following the spirit of this data set, we introduce a new product (RTopo-2) that contains consistent maps of global ocean bathymetry, upper and lower ice surface topographies for Greenland and Antarctica, and global surface height on a spherical grid with now 30 arc seconds resolution. We used the General Bathymetric Chart of the Oceans (GEBCO_2014) as the backbone and added the International Bathymetric Chart of the Arctic Ocean version 3 (IBCAOv3) and the International Bathymetric Chart of the Southern Ocean (IBCSO) version 1. To achieve a good representation of the fjord and shelf bathymetry around the Greenland continent, we corrected data from earlier gridded products in the areas of Petermann Glacier, Hagen Bræ and Helheim Glacier assuming that sub-ice and fjord bathymetries roughly follow plausible Last Glacial Maximum ice flow patterns. For the continental shelf off northeast Greenland and the floating ice tongue of Nioghalvfjerdsfjorden Glacier at about 79°N, we incorporated a high-resolution digital bathymetry model including all available multibeam survey data for the region. Radar data for ice surface and ice base topographies of the floating ice tongues of Nioghalvfjerdsfjorden Glacier and Zachariæ Isstrøm have been obtained from the data centers of Technical University of Denmark (DTU), Operation Icebridge (NASA/NSF) and Alfred Wegener Institute (AWI). For the Antarctic ice sheet/ice shelves, RTopo-2 largely relies on the Bedmap-2 product but applies corrections for the geometry of Getz, Abbot and Fimbul ice shelf cavities. The data set is available in full and in regional subsets in NetCDF format from the PANGAEA database.
Spatial Digital Database for the Geologic Map of Oregon
Walker, George W.; MacLeod, Norman S.; Miller, Robert J.; Raines, Gary L.; Connors, Katherine A.
2003-01-01
Introduction This report describes and makes available a geologic digital spatial database (orgeo) representing the geologic map of Oregon (Walker and MacLeod, 1991). The original paper publication was printed as a single map sheet at a scale of 1:500,000, accompanied by a second sheet containing map unit descriptions and ancillary data. A digital version of the Walker and MacLeod (1991) map was included in Raines and others (1996). The dataset provided by this open-file report supersedes the earlier published digital version (Raines and others, 1996). This digital spatial database is one of many being created by the U.S. Geological Survey as an ongoing effort to provide geologic information for use in spatial analysis in a geographic information system (GIS). This database can be queried in many ways to produce a variety of geologic maps. This database is not meant to be used or displayed at any scale larger than 1:500,000 (for example, 1:100,000). This report describes the methods used to convert the geologic map data into a digital format, describes the ArcInfo GIS file structures and relationships, and explains how to download the digital files from the U.S. Geological Survey public access World Wide Web site on the Internet. Scanned images of the printed map (Walker and MacLeod, 1991), their correlation of map units, and their explanation of map symbols are also available for download.
An Analysis of a Digital Variant of the Trail Making Test Using Machine Learning Techniques
Dahmen, Jessamyn; Cook, Diane; Fellows, Robert; Schmitter-Edgecombe, Maureen
2017-01-01
BACKGROUND The goal of this work is to develop a digital version of a standard cognitive assessment, the Trail Making Test (TMT), and assess its utility. OBJECTIVE This paper introduces a novel digital version of the TMT and introduces a machine learning based approach to assess its capabilities. METHODS Using digital Trail Making Test (dTMT) data collected from (N=54) older adult participants as feature sets, we use machine learning techniques to analyze the utility of the dTMT and evaluate the insights provided by the digital features. RESULTS Predicted TMT scores correlate well with clinical digital test scores (r=0.98) and paper time to completion scores (r=0.65). Predicted TICS exhibited a small correlation with clinically-derived TICS scores (r=0.12 Part A, r=0.10 Part B). Predicted FAB scores exhibited a small correlation with clinically-derived FAB scores (r=0.13 Part A, r=0.29 for Part B). Digitally-derived features were also used to predict diagnosis (AUC of 0.65). CONCLUSION Our findings indicate that the dTMT is capable of measuring the same aspects of cognition as the paper-based TMT. Furthermore, the dTMT’s additional data may be able to help monitor other cognitive processes not captured by the paper-based TMT alone. PMID:27886019
Deighan, C; Michalova, L; Pagliari, C; Elliott, J; Taylor, L; Ranaldi, H
2017-08-01
Patients are seeking greater choice and flexibility in how they engage with self-management programmes. While digital innovations offer opportunities to deliver supportive interventions to patients undergoing cardiac rehabilitation little is known about how accessible, useful and acceptable they are for this group. This project developed a digital version of a leading evidenced cardiac rehabilitation programme, the Heart Manual (HM). The prototype was developed and evaluated iteratively in collaboration with end users. Using a mixed methods design 28 participants provided feedback using semi-structured questionnaires and telephone interviews. Rich data revealed the perceived user-friendliness of the HM digital format and its effectiveness at communicating the programme's key messages. It flagged areas requiring development, such as more flexible and intuitive navigation pathways. These suggestions informed the refinement of the resource. This evaluation offers support for the new Digital Heart Manual and confirms the value of employing a user-centred approach when developing and improving online interventions. The system is now in use and recommendations from the evaluation are being translated into quality improvements. The Digital Heart Manual is user friendly and accessible to patients and health professionals, regardless of age, presenting a suitable alternative to the paper version. Copyright © 2017 Elsevier B.V. All rights reserved.
The psychosocial impact of NHS Digital Badges on a school-aged cohort.
Alexander, Joanne H; Neill, Sarah
2018-01-01
Goal-oriented modalities of learning have long been used in educational settings to promote engagement and encourage a step-by-step approach to the acquisition of skills and knowledge. Historically, badges have been material, but in keeping with technological advancements there is a move towards encouraging greater digital engagement. Digital badges are today's version of the Scouts and Guides badge, a virtual non-material version, increasingly being utilized as a pedagogical resource in education and business settings. In 2015, National Health Service (NHS) England developed and launched its own digital badges aimed at supporting children and young people's education of health and well-being. This article presents findings from the first study to explore the psychosocial impact of NHS Digital Badges as perceived by primary school-aged children and their teachers. We conducted a small-scale evaluation involving children aged 8-10 ( n = 57) and their teachers ( n = 2), from a primary academy (school) in the north of England using NHS Digital Badges in their curriculum. Overwhelmingly, children and teachers reflected on the badges positively, as tools that have the capacity to build perseverance, develop emotional awareness, build relationships and enhance skill and knowledge acquisition. Some participants, though, raised vulnerability and safeguarding issues, and we explore the implications of these for future practice.
Masataka, Nobuo
2014-01-01
Here the author presents preliminary evidence supporting the possibility that the reading ability of 4-year-old children can be improved as a consequence of intensive exposure to the narrative in a digital picture book over a consecutive 5-day period. When creating the digital version used here, two additional functions were provided with it. First, the entire story was voice-recorded by a professional narrator and programmed so that it was played as narration from the speaker of an iPad. Next, as the narration of each digitized page proceeded, the character exactly corresponding to that pronounced by the narrator at that moment became highlighted in red. When the subjects' literacy capability with respect to the syllabic script of the Japanese language (kana) was evaluated before and after the exposure, their performance score was found to increase after the exposure to the digital book, whereas such a change was not recorded in children who experienced exposure to the printed version of the same picture book read to them by their mother. These effects were confirmed when the children were retested 4 weeks later. Although preliminary, the current study represents the first experimental evidence for a positive effect of exposure to digital books upon any aspect of child development.
Masataka, Nobuo
2014-01-01
Here the author presents preliminary evidence supporting the possibility that the reading ability of 4-year-old children can be improved as a consequence of intensive exposure to the narrative in a digital picture book over a consecutive 5-day period. When creating the digital version used here, two additional functions were provided with it. First, the entire story was voice-recorded by a professional narrator and programmed so that it was played as narration from the speaker of an iPad. Next, as the narration of each digitized page proceeded, the character exactly corresponding to that pronounced by the narrator at that moment became highlighted in red. When the subjects' literacy capability with respect to the syllabic script of the Japanese language (kana) was evaluated before and after the exposure, their performance score was found to increase after the exposure to the digital book, whereas such a change was not recorded in children who experienced exposure to the printed version of the same picture book read to them by their mother. These effects were confirmed when the children were retested 4 weeks later. Although preliminary, the current study represents the first experimental evidence for a positive effect of exposure to digital books upon any aspect of child development. PMID:24822051
Experiences with semiautomatic aerotriangulation on digital photogrammetric stations
NASA Astrophysics Data System (ADS)
Kersten, Thomas P.; Stallmann, Dirk
1995-12-01
With the development of higher-resolution scanners, faster image-handling capabilities, and higher-resolution screens, digital photogrammetric workstations promise to rival conventional analytical plotters in functionality, i.e. in the degree of automation in data capture and processing, and in accuracy. The availability of high quality digital image data and inexpensive high capacity fast mass storage offers the capability to perform accurate semi- automatic or automatic triangulation of digital aerial photo blocks on digital photogrammetric workstations instead of analytical plotters. In this paper, we present our investigations and results on two photogrammetric triangulation blocks, the OEEPE (European Organisation for Experimental Photogrammetric Research) test block (scale 1;4'000) and a Swiss test block (scale 1:12'000) using digitized images. Twenty-eight images of the OEEPE test block were scanned on the Zeiss/Intergraph PS1 and the digital images were delivered with a resolution of 15 micrometer and 30 micrometer, while 20 images of the Swiss test block were scanned on the Desktop Publishing Scanner Agfa Horizon with a resolution of 42 micrometer and on the PS1 with 15 micrometer. Measurements in the digital images were performed on the commercial Digital photogrammetric Station Leica/Helava DPW770 and with basic hard- and software components of the Digital Photogrammetric Station DIPS II, an experimental system of the Institute of Geodesy and Photogrammetry, ETH Zurich. As a reference, the analog images of both photogrammetric test blocks were measured at analytical plotters. On DIPS II measurements of fiducial marks, signalized and natural tie points were performed by least squares template and image matching, while on DPW770 all points were measured by the cross correlation technique. The observations were adjusted in a self-calibrating bundle adjustment. The comparisons between these results and the experiences with the functionality of the commercial and the experimental system are presented.
Automatic Mexican sign language and digits recognition using normalized central moments
NASA Astrophysics Data System (ADS)
Solís, Francisco; Martínez, David; Espinosa, Oscar; Toxqui, Carina
2016-09-01
This work presents a framework for automatic Mexican sign language and digits recognition based on computer vision system using normalized central moments and artificial neural networks. Images are captured by digital IP camera, four LED reflectors and a green background in order to reduce computational costs and prevent the use of special gloves. 42 normalized central moments are computed per frame and used in a Multi-Layer Perceptron to recognize each database. Four versions per sign and digit were used in training phase. 93% and 95% of recognition rates were achieved for Mexican sign language and digits respectively.
2010-01-01
the 1/8°climatological monthly mean temperature and salinity fields from the Generalized Digital Environmental Model ( GDEM ) climatology (NAVOCEANO...1424. Page 24 of 51 NAVOCEANO, 2003. Database description for the generalized digital environmental model ( GDEM --V) Version 3.0. OAML--DBD--72
42 CFR 37.52 - Method of obtaining definitive interpretations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... other diseases must be demonstrated by those physicians who desire to be B Readers by taking and passing... specified by NIOSH. Each physician who desires to take the digital version of the examination will be provided a complete set of the current NIOSH-approved standard reference digital radiographs. Physicians...
FIAMODEL: Users Guide Version 3.0.
Scott A. Pugh; David D. Reed; Kurt S. Pregitzer; Patrick D. Miles
2002-01-01
FIAMODEL is a geographic information system (GIS program used to summarize Forest Inventory and Analysis (FIA, USDA Forest Service) data such as volume. The model runs in ArcView and allows users to select FIA plots with heads-up-digitizing, overlays of digital map layers, or queries based on specific plot attributes.
The Last Book: The Delivery of Future Content.
ERIC Educational Resources Information Center
Lim, Edward
This paper discusses the future of the printed book. The first section considers factors contributing to predictions of its eventual demise and replacement by electronic versions, the increasing volume of digitized material, superior characteristics of digital publications, and the development of technologies that will allow the e-book to become…
Cross strip anode readouts for microchannel plate detectors: developing flight qualified prototypes
NASA Astrophysics Data System (ADS)
Vallerga, John; Cooney, M.; Raffanti, R.; Varner, G.; Siegmund, O.; McPhate, J. B.; Tremsin, A.
2014-01-01
Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last two decades (eg. EUVE, FUSE, COS on Hubble etc.). Over this duration, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x 1000) and output event rate (x100), all the while operating at lower gain (x 10) resulting in lower high voltage requirements and longer MCP lifetimes. One such technology is the parallel cross strip (PXS) readout. The PXS anode is a set of orthogonal conducting strips (80 x 80), typically spaced at a 635 micron pitch onto which charge clouds from MCP amplified events land. Each strip has its own charge sensitive amplifier that is sampled continuously by a dedicated analog to digital (ADC) converter at 50MHz. All of the 160 ADC digital output lines are fed into a field programmable gate array (FGPA) which can detect charge events landing on the strips, measure the peak amplitudes of those charge events and calculate their spatial centroid along with their time of arrival (X,Y,T). Laboratory versions of these electronics have demonstrated < 20 microns FWHM spatial resolution, count rates on the order of 2 MHz, and temporal resolution of ~ 1ns. In 2012 the our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a Strategic Astrophysics Technology grant to raise the TRL of the PXS detector from 4 to 6 by replacing most of the 19" rack mounted, high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass and volume requirements of the PXS detector. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration). This detector design could then be modified for individual flight opportunities with a higher level of confidence than starting from scratch. We will present the latest progress on the ASIC designs, fabrication and performance and show imaging results from the 50mm XS detector using our current laboratory PXS electronics.
NASA Astrophysics Data System (ADS)
Aghaei, A.
2017-12-01
Digital imaging and modeling of rocks and subsequent simulation of physical phenomena in digitally-constructed rock models are becoming an integral part of core analysis workflows. One of the inherent limitations of image-based analysis, at any given scale, is image resolution. This limitation becomes more evident when the rock has multiple scales of porosity such as in carbonates and tight sandstones. Multi-scale imaging and constructions of hybrid models that encompass images acquired at multiple scales and resolutions are proposed as a solution to this problem. In this study, we investigate the effect of image resolution and unresolved porosity on petrophysical and two-phase flow properties calculated based on images. A helical X-ray micro-CT scanner with a high cone-angle is used to acquire digital rock images that are free of geometric distortion. To remove subjectivity from the analyses, a semi-automated image processing technique is used to process and segment the acquired data into multiple phases. Direct and pore network based models are used to simulate physical phenomena and obtain absolute permeability, formation factor and two-phase flow properties such as relative permeability and capillary pressure. The effect of image resolution on each property is investigated. Finally a hybrid network model incorporating images at multiple resolutions is built and used for simulations. The results from the hybrid model are compared against results from the model built at the highest resolution and those from laboratory tests.
Carotid Stenosis And Ulcer Detectability As A Function Of Pixel Size
NASA Astrophysics Data System (ADS)
Mintz, Leslie J.; Enzmann, Dieter R.; Keyes, Gary S.; Mainiero, Louis M.; Brody, William R.
1981-11-01
Digital radiography, in conjunction with digital subtraction methods can provide high quality images of the vascular system,1-4 Spatial resolution is one important limiting factor of this imaging technique. Since spatial resolution of a digital image is a function of pixel size, it is important to determine the pixel size threshold necessary to provide information comparable to that of conventional angiograms. This study was designed to establish the pixel size necessary to identify accurately stenotic and ulcerative lesions of the carotid artery.
Airborne remote sensing for geology and the environment; present and future
Watson, Ken; Knepper, Daniel H.
1994-01-01
In 1988, a group of leading experts from government, academia, and industry attended a workshop on airborne remote sensing sponsored by the U.S. Geological Survey (USGS) and hosted by the Branch of Geophysics. The purpose of the workshop was to examine the scientific rationale for airborne remote sensing in support of government earth science in the next decade. This report has arranged the six resulting working-group reports under two main headings: (1) Geologic Remote Sensing, for the reports on geologic mapping, mineral resources, and fossil fuels and geothermal resources; and (2) Environmental Remote Sensing, for the reports on environmental geology, geologic hazards, and water resources. The intent of the workshop was to provide an evaluation of demonstrated capabilities, their direct extensions, and possible future applications, and this was the organizational format used for the geologic remote sensing reports. The working groups in environmental remote sensing chose to present their reports in a somewhat modified version of this format. A final section examines future advances and limitations in the field. There is a large, complex, and often bewildering array of remote sensing data available. Early remote sensing studies were based on data collected from airborne platforms. Much of that technology was later extended to satellites. The original 80-m-resolution Landsat Multispectral Scanner System (MSS) has now been largely superseded by the 30-m-resolution Thematic Mapper (TM) system that has additional spectral channels. The French satellite SPOT provides higher spatial resolution for channels equivalent to MSS. Low-resolution (1 km) data are available from the National Oceanographic and Atmospheric Administration's AVHRR system, which acquires reflectance and day and night thermal data daily. Several experimental satellites have acquired limited data, and there are extensive plans for future satellites including those of Japan (JERS), Europe (ESA), Canada (Radarsat), and the United States (EOS). There are currently two national airborne remote sensing programs (photography, radar) with data archived at the USGS' EROS Data Center. Airborne broadband multispectral data (comparable to Landsat MSS and TM but involving several more channels) for limited geographic areas also are available for digital processing and analysis. Narrow-band imaging spectrometer data are available for some NASA experiment sites and can be acquired for other locations commercially. Remote sensing data and derivative images, because of the uniform spatial coverage, availability at different resolutions, and digital format, are becoming important data sets for geographic information system (GIS) analyses. Examples range from overlaying digitized geologic maps on remote sensing images and draping these over topography, to maps of mineral distribution and inferred abundance. A large variety of remote sensing data sets are available, with costs ranging from a few dollars per square mile for satellite digital data to a few hundred dollars per square mile for airborne imaging spectrometry. Computer processing and analysis costs routinely surpass these expenses because of the equipment and expertise necessary for information extraction and interpretation. Effective use requires both an understanding of the current methodology and an appreciation of the most cost-effective solution.
NASA Astrophysics Data System (ADS)
Jungclaus, J. H.; Fischer, N.; Haak, H.; Lohmann, K.; Marotzke, J.; Matei, D.; Mikolajewicz, U.; Notz, D.; von Storch, J. S.
2013-06-01
MPI-ESM is a new version of the global Earth system model developed at the Max Planck Institute for Meteorology. This paper describes the ocean state and circulation as well as basic aspects of variability in simulations contributing to the fifth phase of the Coupled Model Intercomparison Project (CMIP5). The performance of the ocean/sea-ice model MPIOM, coupled to a new version of the atmosphere model ECHAM6 and modules for land surface and ocean biogeochemistry, is assessed for two model versions with different grid resolution in the ocean. The low-resolution configuration has a nominal resolution of 1.5°, whereas the higher resolution version features a quasiuniform, eddy-permitting global resolution of 0.4°. The paper focuses on important oceanic features, such as surface temperature and salinity, water mass distribution, large-scale circulation, and heat and freshwater transports. In general, these integral quantities are simulated well in comparison with observational estimates, and improvements in comparison with the predecessor system are documented; for example, for tropical variability and sea ice representation. Introducing an eddy-permitting grid configuration in the ocean leads to improvements, in particular, in the representation of interior water mass properties in the Atlantic and in the representation of important ocean currents, such as the Agulhas and Equatorial current systems. In general, however, there are more similarities than differences between the two grid configurations, and several shortcomings, known from earlier versions of the coupled model, prevail.
Nobukawa, Teruyoshi; Nomura, Takanori
2017-01-23
Digital super-resolution holographic data storage based on Hermitian symmetry is proposed to store digital data in a tiny area of a medium. In general, reducing a recording area with an aperture leads to the improvement in the storage capacity of holographic data storage. Conventional holographic data storage systems however have a limitation in reducing a recording area. This limitation is called a Nyquist size. Unlike the conventional systems, our proposed system can overcome the limitation with the help of a digital holographic technique and digital signal processing. Experimental result shows that the proposed system can record and retrieve a hologram in a smaller area than the Nyquist size on the basis of Hermitian symmetry.
Dual-energy in mammography: feasibility study
NASA Astrophysics Data System (ADS)
Jafroudi, Hamid; Lo, Shih-Chung B.; Li, Huai; Steller Artz, Dorothy E.; Freedman, Matthew T.; Mun, Seong K.
1996-04-01
The purpose of this work is to examine the feasibility of dual-energy techniques to enhance the detection of microcalcifications in digital mammography. The digital mammography system used in this study consists of two different mammography systems; one is the conventional mammography system with molybdenum target and Mo filtration and the other is the clinical version of a low dose x-ray system with tungsten target and aluminum filtration. The low dose system is optimized for screen-film mammography with a highly efficient scatter rejection device built by Fischer Imaging Systems for evaluation at NIH. The system was designed by the University of Southern California based on multiparameter optimization techniques. Prototypes of this system have been constructed and evaluated at the Center for Devices and Radiological Health. The digital radiography system is based on the Fuji 9000 computed radiography (CR) system which uses a storage phosphor imaging plate as the receptor. High resolution plates (HR-V) are used in this study. Dual-energy is one technique to reduce the structured noise associated with the complexity of the background of normal anatomy surrounding a lesion. This can be done by taking the advantage of the x-ray attenuation characteristics of two different structures such as soft tissue and bone in chest radiography. We have applied this technique to the detection of microcalcifications in mammography. The overall system performance based on this technique is evaluated. Results presented are based on the evaluation of phantom images.
The U.S. Geological Survey mapping and cartographic database activities, 2006-2010
Craun, Kari J.; Donnelly, John P.; Allord, Gregory J.
2011-01-01
The U.S. Geological Survey (USGS) began systematic topographic mapping of the United States in the 1880s, beginning with scales of 1:250,000 and 1:125,000 in support of geological mapping. Responding to the need for higher resolution and more detail, the 1:62,500-scale, 15-minute, topographic map series was begun in the beginning of the 20th century. Finally, in the 1950s the USGS adopted the 1:24,000-scale, 7.5-minute topographic map series to portray even more detail, completing the coverage of the conterminous 48 states of the United States with this series in 1992. In 2001, the USGS developed the vision and concept of The National Map, a topographic database for the 21st century and the source for a new generation of topographic maps (http://nationalmap.gov/). In 2008, the initial production of those maps began with a 1:24,000-scale digital product. In a separate, but related project, the USGS began scanning the existing inventory of historical topographic maps at all scales to accompany the new topographic maps. The USGS also had developed a digital database of The National Atlas of the United States. The digital version of Atlas is now Web-available and supports a mapping engine for small scale maps of the United States and North America. These three efforts define topographic mapping activities of the USGS during the last few years and are discussed below.
180-GHz Interferometric Imager
NASA Technical Reports Server (NTRS)
Kangaslahti, Pekka P.; Lim, Boon H.; O'Dwyer, Ian J.; Soria, Mary M.; Owen, Heather R.; Gaier, Todd C.; Lambrigtsen, Bjorn, H.; Tanner, Alan B.; Ruf, Christopher
2011-01-01
A 180-GHz interferometric imager uses compact receiver modules, combined high- and low-gain antennas, and ASIC (application specific integrated circuit) correlator technology, enabling continuous, all-weather observations of water vapor with 25-km resolution and 0.3-K noise in 15 minutes of observation for numerical weather forecasting and tropical storm prediction. The GeoSTAR-II prototype instrument is broken down into four major subsystems: the compact, low-noise receivers; sub-array modules; IF signal distribution; and the digitizer/correlator. Instead of the single row of antennas adopted in GeoSTAR, this version has four rows of antennas on a coarser grid. This dramatically improves the sensitivity in the desired field of view. The GeoSTAR-II instrument is a 48-element, synthetic, thinned aperture radiometer operating at 165-183 GHz. The instrument has compact receivers integrated into tiles of 16 elements in a 4x4 arrangement. These tiles become the building block of larger arrays. The tiles contain signal distribution for bias controls, IF signal, and local oscillator signals. The IF signals are digitized and correlated using an ASIC correlator to minimize power consumption. Previous synthetic aperture imagers have used comparatively large multichip modules, whereas this approach uses chip-scale modules mounted on circuit boards, which are in turn mounted on the distribution manifolds. This minimizes the number of connectors and reduces system mass. The use of ASIC technology in the digitizers and correlators leads to a power reduction close to an order of magnitude.
Applying and extending ISO/TC42 digital camera resolution standards to mobile imaging products
NASA Astrophysics Data System (ADS)
Williams, Don; Burns, Peter D.
2007-01-01
There are no fundamental differences between today's mobile telephone cameras and consumer digital still cameras that suggest many existing ISO imaging performance standards do not apply. To the extent that they have lenses, color filter arrays, detectors, apertures, image processing, and are hand held, there really are no operational or architectural differences. Despite this, there are currently differences in the levels of imaging performance. These are driven by physical and economic constraints, and image-capture conditions. Several ISO standards for resolution, well established for digital consumer digital cameras, require care when applied to the current generation of cell phone cameras. In particular, accommodation of optical flare, shading non-uniformity and distortion are recommended. We offer proposals for the application of existing ISO imaging resolution performance standards to mobile imaging products, and suggestions for extending performance standards to the characteristic behavior of camera phones.
NASA Astrophysics Data System (ADS)
Mandai, Shingo; Jain, Vishwas; Charbon, Edoardo
2014-02-01
This paper presents a digital silicon photomultiplier (SiPM) partitioned in columns, whereas each column is connected to a column-parallel time-to-digital converter (TDC), in order to improve the timing resolution of single-photon detection. By reducing the number of pixels per TDC using a sharing scheme with three TDCs per column, the pixel-to-pixel skew is reduced. We report the basic characterization of the SiPM, comprising 416 single-photon avalanche diodes (SPADs); the characterization includes photon detection probability, dark count rate, afterpulsing, and crosstalk. We achieved 264-ps full-width at half maximum timing resolution of single-photon detection using a 48-fold column-parallel TDC with a temporal resolution of 51.8 ps (least significant bit), fully integrated in standard complementary metal-oxide semiconductor technology.
A DVD Spectroscope: A Simple, High-Resolution Classroom Spectroscope
ERIC Educational Resources Information Center
Wakabayashi, Fumitaka; Hamada, Kiyohito
2006-01-01
Digital versatile disks (DVDs) have successfully made up an inexpensive but high-resolution spectroscope suitable for classroom experiments that can easily be made with common material and gives clear and fine spectra of various light sources and colored material. The observed spectra can be photographed with a digital camera, and such images can…
NASA Astrophysics Data System (ADS)
Valiya Peedikakkal, Liyana; Cadby, Ashley
2017-02-01
Localization based super resolution images of a biological sample is generally achieved by using high power laser illumination with long exposure time which unfortunately increases photo-toxicity of a sample, making super resolution microscopy, in general, incompatible with live cell imaging. Furthermore, the limitation of photobleaching reduces the ability to acquire time lapse images of live biological cells using fluorescence microscopy. Digital Light Processing (DLP) technology can deliver light at grey scale levels by flickering digital micromirrors at around 290 Hz enabling highly controlled power delivery to samples. In this work, Digital Micromirror Device (DMD) is implemented in an inverse Schiefspiegler telescope setup to control the power and pattern of illumination for super resolution microscopy. We can achieve spatial and temporal patterning of illumination by controlling the DMD pixel by pixel. The DMD allows us to control the power and spatial extent of the laser illumination. We have used this to show that we can reduce the power delivered to the sample to allow for longer time imaging in one area while achieving sub-diffraction STORM imaging in another using higher power densities.
Low-cost conversion of the Polaroid MD-4 land camera to a digital gel documentation system.
Porch, Timothy G; Erpelding, John E
2006-04-30
A simple, inexpensive design is presented for the rapid conversion of the popular MD-4 Polaroid land camera to a high quality digital gel documentation system. Images of ethidium bromide stained DNA gels captured using the digital system were compared to images captured on Polaroid instant film. Resolution and sensitivity were enhanced using the digital system. In addition to the low cost and superior image quality of the digital system, there is also the added convenience of real-time image viewing through the swivel LCD of the digital camera, wide flexibility of gel sizes, accurate automatic focusing, variable image resolution, and consistent ease of use and quality. Images can be directly imported to a computer by using the USB port on the digital camera, further enhancing the potential of the digital system for documentation, analysis, and archiving. The system is appropriate for use as a start-up gel documentation system and for routine gel analysis.
The x-ray light valve: a low-cost, digital radiographic imaging system-spatial resolution
NASA Astrophysics Data System (ADS)
MacDougall, Robert D.; Koprinarov, Ivaylo; Webster, Christie A.; Rowlands, J. A.
2007-03-01
In recent years, new x-ray radiographic systems based on large area flat panel technology have revolutionized our capability to produce digital x-ray radiographic images. However, these active matrix flat panel imagers (AMFPIs) are extraordinarily expensive compared to the systems they are replacing. Thus there is a need for a low cost digital imaging system for general applications in radiology. Different approaches have been considered to make lower cost, integrated x-ray imaging devices for digital radiography, including: scanned projection x-ray, an integrated approach based on computed radiography technology and optically demagnified x-ray screen/CCD systems. These approaches suffer from either high cost or high mechanical complexity and do not have the image quality of AMFPIs. We have identified a new approach - the X-ray Light Valve (XLV). The XLV has the potential to achieve the immediate readout in an integrated system with image quality comparable to AMFPIs. The XLV concept combines three well-established and hence lowcost technologies: an amorphous selenium (a-Se) layer to convert x-rays to image charge, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. Here we investigate the spatial resolution possible with XLV systems. Both a-Se and LC cells have both been shown separately to have inherently very high spatial resolution. Due to the close electrostatic coupling in the XLV, it can be expected that the spatial resolution of this system will also be very high. A prototype XLV was made and a typical office scanner was used for image digitization. The Modulation Transfer Function was measured and the limiting factor was seen to be the optical scanner. However, even with this limitation the XLV system is able to meet or exceed the resolution requirements for chest radiography.
Time-series photographs of the sea floor in western Massachusetts Bay, version 2, 1989-1993
Butman, Bradford; Dalyander, P. Soupy; Bothner, Michael H.; Lange, William N.
2008-01-01
Time-series photographs of the sea floor were obtained from an instrumented tripod deployed in western Massachusetts Bay at LT-A (42° 22.6' N, 70° 47.0' W; nominal water depth of 32 m; fig. 1) from December 1989 through September 2005. The photographs provide time-series observations of physical changes of the sea floor, near-bottom water turbidity, and life on the sea floor. Several reports present these photographs in digital form (table 1). This report, U.S. Geological Survey Data Series 265, Version 2.0, contains the photographs obtained from December 1989 to October 1996, adding to (and replacing) Version 1 of Data Series 265 (Butman and others, 2007a) that contained photographs from 1989 through 1993. Data Series 266 (Butman and others, 2008b) contains photographs obtained from October 1996 through September 2005. The photographs are published in separate reports because the data files are too large for distribution on a single DVD. These reports present the photographs, originally collected on 35-mm film, in digital form to enable easy viewing and to provide a medium-resolution digital archive. The photographs, obtained every 4 or every 6 hours, are presented as individual photographs (in .png format) and as a movie (in .avi format). The time-series photographs taken at LT-A were collected as part of a U.S. Geological Survey (USGS) study to understand the transport and fate of sediments and associated contaminants in Massachusetts Bay and Cape Cod Bay (Bothner and Butman, 2007). This long-term study was carried out by the USGS in partnership with the Massachusetts Water Resources Authority (MWRA) (http://www.mwra.state.ma.us/) and with logistical support from the U.S. Coast Guard (USCG). Long-term oceanographic observations help to identify the processes causing bottom sediment resuspension and transport and provide data for developing and testing numerical models. The observations document seasonal and interannual changes in currents, hydrography, suspended-matter concentration, and the importance of infrequent catastrophic events, such as major storms, in sediment resuspension and transport. LT-A is approximately 1 km south of the ocean outfall that began discharging treated sewage effluent from the Boston metropolitan area into Massachusetts Bay in September 2000. See Butman and others (2004d) for a description of the oceanographic measurements at LT-A, and Butman and others (2007c) and Warner and others (2008) for discussion of sediment transport in Massachusetts Bay.
NASA Astrophysics Data System (ADS)
Briggl, K.; Dorn, M.; Hagdorn, R.; Harion, T.; Schultz-Coulon, H. C.; Shen, W.
2014-02-01
KLauS is an ASIC produced in the AMS 0.35 μm SiGe process to read out the charge signals from silicon photomultipliers. Developed as an analog front-end for future calorimeters with high granularity as pursued by the AHCAL concept in the CALICE collaboration, the ASIC is designed to measure the charge signal of the sensors in a large dynamic range and with low electronic noise contributions. In order to tune the operation voltage of each sensor individually, an 8-bit DAC to tune the voltage at the input terminal within a range of 2V is implemented. Using an integrated fast comparator with low jitter, the time information can be measured with sub-nanosecond resolution. The low power consumption of the ASIC can be further decreased using power gating techniques. Future versions of KLauS are under development and will incorporate an ADC with a resolution of up to 12-bits and blocks for digital data transmission. The chip is used in a setup for mass testing and characterization of scintillator tiles for the AHCAL test beam program.
Software for biomedical engineering signal processing laboratory experiments.
Tompkins, Willis J; Wilson, J
2009-01-01
In the early 1990's we developed a special computer program called UW DigiScope to provide a mechanism for anyone interested in biomedical digital signal processing to study the field without requiring any other instrument except a personal computer. There are many digital filtering and pattern recognition algorithms used in processing biomedical signals. In general, students have very limited opportunity to have hands-on access to the mechanisms of digital signal processing. In a typical course, the filters are designed non-interactively, which does not provide the student with significant understanding of the design constraints of such filters nor their actual performance characteristics. UW DigiScope 3.0 is the first major update since version 2.0 was released in 1994. This paper provides details on how the new version based on MATLAB! works with signals, including the filter design tool that is the programming interface between UW DigiScope and processing algorithms.
Development of the geoCamera, a System for Mapping Ice from a Ship
NASA Astrophysics Data System (ADS)
Arsenault, R.; Clemente-Colon, P.
2012-12-01
The geoCamera produces maps of the ice surrounding an ice-capable ship by combining images from one or more digital cameras with the ship's position and attitude data. Maps are produced along the ship's path with the achievable width and resolution depending on camera mounting height as well as camera resolution and lens parameters. Our system has produced maps up to 2000m wide at 1m resolution. Once installed and calibrated, the system is designed to operate automatically producing maps in near real-time and making them available to on-board users via existing information systems. The resulting small-scale maps complement existing satellite based products as well as on-board observations. Development versions have temporarily been deployed in Antarctica on the RV Nathaniel B. Palmer in 2010 and in the Arctic on the USCGC Healy in 2011. A permanent system has been deployed during the summer of 2012 on the USCGC Healy. To make the system attractive to other ships of opportunity, design goals include using existing ship systems when practical, using low costs commercial-off-the-shelf components if additional hardware is necessary, automating the process to virtually eliminate adding to the workload of ships technicians and making the software components modular and flexible enough to allow more seamless integration with a ships particular IT system.
NASA Astrophysics Data System (ADS)
Zarzycki, C. M.; Gettelman, A.; Callaghan, P.
2017-12-01
Accurately predicting weather extremes such as precipitation (floods and droughts) and temperature (heat waves) requires high resolution to resolve mesoscale dynamics and topography at horizontal scales of 10-30km. Simulating such resolutions globally for climate scales (years to decades) remains computationally impractical. Simulating only a small region of the planet is more tractable at these scales for climate applications. This work describes global simulations using variable-resolution static meshes with multiple dynamical cores that target the continental United States using developmental versions of the Community Earth System Model version 2 (CESM2). CESM2 is tested in idealized, aquaplanet and full physics configurations to evaluate variable mesh simulations against uniform high and uniform low resolution simulations at resolutions down to 15km. Different physical parameterization suites are also evaluated to gauge their sensitivity to resolution. Idealized variable-resolution mesh cases compare well to high resolution tests. More recent versions of the atmospheric physics, including cloud schemes for CESM2, are more stable with respect to changes in horizontal resolution. Most of the sensitivity is due to sensitivity to timestep and interactions between deep convection and large scale condensation, expected from the closure methods. The resulting full physics model produces a comparable climate to the global low resolution mesh and similar high frequency statistics in the high resolution region. Some biases are reduced (orographic precipitation in the western United States), but biases do not necessarily go away at high resolution (e.g. summertime JJA surface Temp). The simulations are able to reproduce uniform high resolution results, making them an effective tool for regional climate studies and are available in CESM2.
Intensity Interferometry: Imaging Stars with Kilometer Baselines
NASA Astrophysics Data System (ADS)
Dravins, Dainis
2018-04-01
Microarcsecond imaging will reveal stellar surfaces but requires kilometer-scale interferometers. Intensity interferometry circumvents atmospheric turbulence by correlating intensity fluctuations between independent telescopes. Telescopes connect only electronically, and the error budget relates to electronic timescales of nanoseconds (light-travel distances on the order of a meter), enabling the use of imperfect optics in a turbulent atmosphere. Once pioneered by Hanbury Brown and Twiss, digital versions have now been demonstrated in the laboratory, reconstructing diffraction-limited images from hundreds of optical baselines. Arrays of Cherenkov telescopes (primarily erected for gamma-ray studies) will extend over a few km, enabling an optical equivalent of radio interferometers. Resolutions in the tens of microarcseconds will resolve rotationally flattened stars with their circumstellar disks and winds, or possibly even the silhouettes of transiting exoplanets. Applying the method to mirror segments in extremely large telescopes (even with an incompletely filled main mirror, poor seeing, no adaptive optics), the diffraction limit in the blue may be reached.
A study of digital holographic filter generation
NASA Technical Reports Server (NTRS)
Calhoun, M.; Ingels, F.
1976-01-01
Problems associated with digital computer generation of holograms are discussed along with a criteria for producing optimum digital holograms. This criteria revolves around amplitude resolution and spatial frequency limitations induced by the computer and plotter process.
Intra-arterial thrombolysis of digital artery occlusions in a patient with polycythemia vera.
Jud, Philipp; Hafner, Franz; Gary, Thomas; Ghanim, Leyla; Lipp, Rainer; Brodmann, Marianne
2017-01-01
There are limited therapeutic options for the resolution of digital artery occlusions. Intra-arterial thrombolysis with anticoagulative and thrombolytic drugs successfully restored the blood flow in the affected digital arteries.
NASA Astrophysics Data System (ADS)
Cruden, A. R.; Vollgger, S.
2016-12-01
The emerging capability of UAV photogrammetry combines a simple and cost-effective method to acquire digital aerial images with advanced computer vision algorithms that compute spatial datasets from a sequence of overlapping digital photographs from various viewpoints. Depending on flight altitude and camera setup, sub-centimeter spatial resolution orthophotographs and textured dense point clouds can be achieved. Orientation data can be collected for detailed structural analysis by digitally mapping such high-resolution spatial datasets in a fraction of time and with higher fidelity compared to traditional mapping techniques. Here we describe a photogrammetric workflow applied to a structural study of folds and fractures within alternating layers of sandstone and mudstone at a coastal outcrop in SE Australia. We surveyed this location using a downward looking digital camera mounted on commercially available multi-rotor UAV that autonomously followed waypoints at a set altitude and speed to ensure sufficient image overlap, minimum motion blur and an appropriate resolution. The use of surveyed ground control points allowed us to produce a geo-referenced 3D point cloud and an orthophotograph from hundreds of digital images at a spatial resolution < 10 mm per pixel, and cm-scale location accuracy. Orientation data of brittle and ductile structures were semi-automatically extracted from these high-resolution datasets using open-source software. This resulted in an extensive and statistically relevant orientation dataset that was used to 1) interpret the progressive development of folds and faults in the region, and 2) to generate a 3D structural model that underlines the complex internal structure of the outcrop and quantifies spatial variations in fold geometries. Overall, our work highlights how UAV photogrammetry can contribute to new insights in structural analysis.
DOT National Transportation Integrated Search
2015-10-31
In 2012, the Navy requested spectrum certification for the shipboard AN/UPX-41(C) Digital Interrogator System, Software Version 5.5 with Mode 5. Current operating conditions for the Navys AN/UPX-41(C) are the same as restrictions imposed on the AN...
Archive and Database as Metaphor: Theorizing the Historical Record
ERIC Educational Resources Information Center
Manoff, Marlene
2010-01-01
Digital media increase the visibility and presence of the past while also reshaping our sense of history. We have extraordinary access to digital versions of books, journals, film, television, music, art and popular culture from earlier eras. New theoretical formulations of database and archive provide ways to think creatively about these changes…
ERIC Educational Resources Information Center
Annand, David
2002-01-01
Describes the simultaneous development of paper-based and digitized versions of a textbook and related instructional material used in an undergraduate, independent study, distance education course at Athabasca University (Canada). Used break-even analysis as an initial evaluation measure to determine cost-effectiveness, and discusses the next…
Trading Spaces: An Educator's Ethnographic Exploration of Adolescents' Digital Role-Play
ERIC Educational Resources Information Center
Haynes-Moore, Stacy
2015-01-01
In this work, the author examines a digital role-play in which participants composed an alternate version of "The Hunger Games" (Collins, 2008). Participants imagined characters and posted more than 400 scenes in the online collaboration. The author draws upon ethnographic methods (Merriam, 2009) to describe her participant-observer…
NASA Technical Reports Server (NTRS)
Lohn, Jason; Smith, David; Frank, Jeremy; Globus, Al; Crawford, James
2007-01-01
JavaGenes is a general-purpose, evolutionary software system written in Java. It implements several versions of a genetic algorithm, simulated annealing, stochastic hill climbing, and other search techniques. This software has been used to evolve molecules, atomic force field parameters, digital circuits, Earth Observing Satellite schedules, and antennas. This version differs from version 0.7.28 in that it includes the molecule evolution code and other improvements. Except for the antenna code, JaveGenes is available for NASA Open Source distribution.
Present and Future Applications of Digital Electronics in Nuclear Science - a Commercial Prospective
NASA Astrophysics Data System (ADS)
Tan, Hui
2011-10-01
Digital readout electronics instrumenting radiation detectors have experienced significant advancements in the last decade or so. This on one hand can be attributed to the steady improvements in commercial digital processing components such as analog-to-digital converters (ADCs), digital-to-analog converters (DACs), field-programmable-gate-arrays (FPGAs), and digital-signal-processors (DSPs), and on the other hand can also be attributed to the increasing needs for improved time, position, and energy resolution in nuclear physics experiments, which have spurred the rapid development of commercial off-the-shelf high speed, high resolution digitizers or spectrometers. Absent from conventional analog electronics, the capability to record fast decaying pulses from radiation detectors in digital readout electronics has profoundly benefited nuclear physics researchers since they now can perform detailed pulse processing for applications such as gamma-ray tracking and decay-event selection and reconstruction. In this talk, present state-of-the-art digital readout electronics and its applications in a variety of nuclear science fields will be discussed, and future directions in hardware development for digital electronics will also be outlined, all from the prospective of a commercial manufacturer of digital electronics.
World Digital Magnetic Anomaly Map version 2 (WDMAM v.2) - released for research and education
NASA Astrophysics Data System (ADS)
CHOI-Dyment, Y.; Lesur, V.; Dyment, J.; Hamoudi, M.; Thebault, E.; Catalan, M.
2015-12-01
The World Digital Magnetic Anomaly Map is an international initiative carried out under the auspices of the International Association of Geomagnetism and Aeronomy (IAGA) and the Commission for the Geological Map of the World (CGMW). A first version of the map has been published and distributed eight years ago (WDMAM v1; Korhonen et al., 2007). We have produced a candidate which has been accepted as the second version of this map (WDMAM v2) at the International Union of Geophysics and Geodesy in Prag, in June 2015. On land, we adopted an alternative approach avoiding any unnecessary processing on existing aeromagnetic compilations. When available, we used the original aeromagnetic data. As a result the final compilation remains an acceptable representation of the national and international data grids. Over oceanic areas the marine data have been extended. In areas of insufficient data coverage, a model has been computed based on a modified digital grid of the oceanic lithosphere age, considering plate motions in the determination of magnetization vector directions. This model has been further adjusted to the available data, resulting in a better representation of the anomalies. The final grid will be periodically upgraded. Version 2.0 has been released and is available at wdmam.org to support both research and education projects. Colleagues willing to contribute data for future releases (and become a co-author of the map) should contact any of the authors or Jerome Dyment (chair of the WDMAM Task Force) at jdy@ipgp.fr .
NASA Astrophysics Data System (ADS)
Wen, Sy-Bor; Bhaskar, Arun; Zhang, Hongjie
2018-07-01
A scanning digital lithography system using computer controlled digital spatial light modulator, spatial filter, infinity correct optical microscope and high precision translation stage is proposed and examined. Through utilizing the spatial filter to limit orders of diffraction modes for light delivered from the spatial light modulator, we are able to achieve diffraction limited deep submicron spatial resolution with the scanning digital lithography system by using standard one inch level optical components with reasonable prices. Raster scanning of this scanning digital lithography system using a high speed high precision x-y translation stage and piezo mount to real time adjust the focal position of objective lens allows us to achieve large area sub-micron resolved patterning with high speed (compared with e-beam lithography). It is determined in this study that to achieve high quality stitching of lithography patterns with raster scanning, a high-resolution rotation stage will be required to ensure the x and y directions of the projected pattern are in the same x and y translation directions of the nanometer precision x-y translation stage.
The influence of software filtering in digital mammography image quality
NASA Astrophysics Data System (ADS)
Michail, C.; Spyropoulou, V.; Kalyvas, N.; Valais, I.; Dimitropoulos, N.; Fountos, G.; Kandarakis, I.; Panayiotakis, G.
2009-05-01
Breast cancer is one of the most frequently diagnosed cancers among women. Several techniques have been developed to help in the early detection of breast cancer such as conventional and digital x-ray mammography, positron and single-photon emission mammography, etc. A key advantage in digital mammography is that images can be manipulated as simple computer image files. Thus non-dedicated commercially available image manipulation software can be employed to process and store the images. The image processing tools of the Photoshop (CS 2) software usually incorporate digital filters which may be used to reduce image noise, enhance contrast and increase spatial resolution. However, improving an image quality parameter may result in degradation of another. The aim of this work was to investigate the influence of three sharpening filters, named hereafter sharpen, sharpen more and sharpen edges on image resolution and noise. Image resolution was assessed by means of the Modulation Transfer Function (MTF).In conclusion it was found that the correct use of commercial non-dedicated software on digital mammograms may improve some aspects of image quality.
Generating High resolution surfaces from images: when photogrammetry and applied geophysics meets
NASA Astrophysics Data System (ADS)
Bretar, F.; Pierrot-Deseilligny, M.; Schelstraete, D.; Martin, O.; Quernet, P.
2012-04-01
Airborne digital photogrammetry has been used for some years to create digital models of the Earth's topography from calibrated cameras. But, in the recent years, the use of non-professionnal digital cameras has become valuable to reconstruct topographic surfaces. Today, the multi megapixel resolution of non-professionnal digital cameras, either used in a close range configuration or from low altitude flights, provide a ground pixel size of respectively a fraction of millimeters to couple of centimeters. Such advances turned into reality because the data processing chain made a tremendous break through during the last five years. This study investigates the potential of the open source software MICMAC developed by the French National Survey IGN (http://www.micmac.ign.fr) to calibrate unoriented digital images and calculate surface models of extremely high resolution for Earth Science purpose. We would like to report two experiences performed in 2011. The first has been performed in the context of risk assessment of rock falls and landslides along the cliffs of Normandy seashore. The acquisition protocol for the first site of "Criel-sur-Mer" has been very simple: a walk along the chalk vertical cliffs taking photos with a focal of 18mm every approx. 50m with an overlap of 80% allowed to generate 2.5km of digital surface at centimeter resolution. The site of "Les Vaches Noires" has been more complicated to acquire because of both the geology (dark clays) and the geometry (the landslide direction is parallel to the seashore and has a high field depth from the shore). We therefore developed an innovative device mounted on board of an autogyre (in-between ultralight power driven aircraft and helicopter). The entire area has been surveyed with a focal of 70mm at 400m asl with a ground pixel of 3cm. MICMAC gives the possibility to directly georeference digital Model. Here, it has been performed by a net of wireless GPS called Geocubes, also developed at IGN. The second experience is a part of field measurements performed over the flanks of the volcano Piton de la Fournaise, La Réunion island. In order to characterize the roughness of different type of lava flows, extremely high resolution Digital Terrain Models (0.6mm) have been generated with MICMAC. The use of such high definition topography made the characterization possible through the calculation of the correlation length, the standard deviation and the fractal dimension. To conclude, we will sketch a synthesis of the need of geoscientists vs. the optimal resolution of digital topographic data.
Clinical applications of computerized thermography
NASA Technical Reports Server (NTRS)
Anbar, Michael
1988-01-01
Computerized or digital, thermography is a rapidly growing diagnostic imaging modality. It has superseded contact thermography and analog imaging thermography which do not allow effective quantization. Medical applications of digital thermography can be classified in two groups: static and dynamic imaging. They can also be classified into macro thermography (resolution greater than 1 mm) and micro thermography (resolution less than 100 microns). Both modalities allow a thermal resolution of 0.1 C. The diagnostic power of images produced by any of these modalities can be augmented by the use of digital image enhancement and image recognition procedures. Computerized thermography has been applied in neurology, cardiovascular and plastic surgery, rehabilitation and sports medicine, psychiatry, dermatology and ophthalmology. Examples of these applications are shown and their scope and limitations are discussed.
Development of the GEOS-5 Atmospheric General Circulation Model: Evolution from MERRA to MERRA2.
NASA Technical Reports Server (NTRS)
Molod, Andrea; Takacs, Lawrence; Suarez, Max; Bacmeister, Julio
2014-01-01
The Modern-Era Retrospective Analysis for Research and Applications-2 (MERRA2) version of the GEOS-5 (Goddard Earth Observing System Model - 5) Atmospheric General Circulation Model (AGCM) is currently in use in the NASA Global Modeling and Assimilation Office (GMAO) at a wide range of resolutions for a variety of applications. Details of the changes in parameterizations subsequent to the version in the original MERRA reanalysis are presented here. Results of a series of atmosphere-only sensitivity studies are shown to demonstrate changes in simulated climate associated with specific changes in physical parameterizations, and the impact of the newly implemented resolution-aware behavior on simulations at different resolutions is demonstrated. The GEOS-5 AGCM presented here is the model used as part of the GMAO's MERRA2 reanalysis, the global mesoscale "nature run", the real-time numerical weather prediction system, and for atmosphere-only, coupled ocean-atmosphere and coupled atmosphere-chemistry simulations. The seasonal mean climate of the MERRA2 version of the GEOS-5 AGCM represents a substantial improvement over the simulated climate of the MERRA version at all resolutions and for all applications. Fundamental improvements in simulated climate are associated with the increased re-evaporation of frozen precipitation and cloud condensate, resulting in a wetter atmosphere. Improvements in simulated climate are also shown to be attributable to changes in the background gravity wave drag, and to upgrades in the relationship between the ocean surface stress and the ocean roughness. The series of "resolution aware" parameters related to the moist physics were shown to result in improvements at higher resolutions, and result in AGCM simulations that exhibit seamless behavior across different resolutions and applications.
USGS Releases New Digital Aerial Products
,
2005-01-01
The U.S. Geological Survey (USGS) Center for Earth Resources Observation and Science (EROS) has initiated distribution of digital aerial photographic products produced by scanning or digitizing film from its historical aerial photography film archive. This archive, located in Sioux Falls, South Dakota, contains thousands of rolls of film that contain more than 8 million frames of historic aerial photographs. The largest portion of this archive consists of original film acquired by Federal agencies from the 1930s through the 1970s to produce 1:24,000-scale USGS topographic quadrangle maps. Most of this photography is reasonably large scale (USGS photography ranges from 1:8,000 to 1:80,000) to support the production of the maps. Two digital products are currently available for ordering: high-resolution scanned products and medium-resolution digitized products.
Gehrels, George E.; Berg, Henry C.
2006-01-01
The growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO export files and as ArcView shape files. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set of 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
Digital Data for the reconnaissance geologic map for the Kuskokwim Bay Region of Southwest Alaska
Wilson, Frederic H.; Hults, Chad P.; Mohadjer, Solmaz; Coonrad, Warren L.; Shew, Nora B.; Labay, Keith A.
2008-01-01
INTRODUCTION The growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO export files and as ArcView shape files. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
The paced auditory serial addition test for working memory assessment: Psychometric properties
Nikravesh, Maryam; Jafari, Zahra; Mehrpour, Masoud; Kazemi, Roozbeh; Amiri Shavaki, Younes; Hossienifar, Shamim; Azizi, Mohamad Parsa
2017-01-01
Background: The paced auditory serial addition test (PASAT) was primarily developed to assess the effects of traumatic brain injury on cognitive functioning. Working memory (WM) is one of the most important aspects of cognitive function, and WM impairment is one of the clinically remarkable signs of aphasia. To develop the Persian version of PASAT, an initial version was used in individuals with aphasia (IWA). Methods: In this study, 25 individuals with aphasia (29-60 years) and 85 controls (18-60 years) were included. PASAT was presented in the form of recorded 61 single-digit numbers (1 to 9). The participants repeatedly added the 2 recent digits. The psychometric properties of PASAT including convergent validity (using the digit memory span tasks), divergent validity (using results in the control group and IWA group), and face validity were investigated. Test-retest reliability was considered as well. Results: The relationship between the PASAT and digit memory span tests was moderate to strong in the control group (forward digit memory span test: r= 0.52, p< 0.0001; backward digit memory span test: r = 0.48, p< 0.0001). A strong relationship was found in IWA (forward digit memory span test: r= 0.72, p< 0.0001; backward digit memory span test: r= 0.53, p= 0.006). Also, strong testretest reliability (intraclass correlation= 0.95, p< 0.0001) was observed. Conclusion: According to our results, the PASAT is a valid and reliable test to assess working memory, particularly in IWA. It could be used as a feasible tool for clinical and research applications. PMID:29445690
Multicomponent analysis of a digital Trail Making Test.
Fellows, Robert P; Dahmen, Jessamyn; Cook, Diane; Schmitter-Edgecombe, Maureen
2017-01-01
The purpose of the current study was to use a newly developed digital tablet-based variant of the TMT to isolate component cognitive processes underlying TMT performance. Similar to the paper-based trail making test, this digital variant consists of two conditions, Part A and Part B. However, this digital version automatically collects additional data to create component subtest scores to isolate cognitive abilities. Specifically, in addition to the total time to completion and number of errors, the digital Trail Making Test (dTMT) records several unique components including the number of pauses, pause duration, lifts, lift duration, time inside each circle, and time between circles. Participants were community-dwelling older adults who completed a neuropsychological evaluation including measures of processing speed, inhibitory control, visual working memory/sequencing, and set-switching. The abilities underlying TMT performance were assessed through regression analyses of component scores from the dTMT with traditional neuropsychological measures. Results revealed significant correlations between paper and digital variants of Part A (r s = .541, p < .001) and paper and digital versions of Part B (r s = .799, p < .001). Regression analyses with traditional neuropsychological measures revealed that Part A components were best predicted by speeded processing, while inhibitory control and visual/spatial sequencing were predictors of specific components of Part B. Exploratory analyses revealed that specific dTMT-B components were associated with a performance-based medication management task. Taken together, these results elucidate specific cognitive abilities underlying TMT performance, as well as the utility of isolating digital components.
Digital ionosonde studies of F-region waves. [measuring ionospheric disturbances
NASA Technical Reports Server (NTRS)
Harper, R. M.; Bowhill, S. A.
1974-01-01
Accurate fixed-frequency virtual height data collected on a digital ionosonde are analyzed to measure speed and direction of traveling ionospheric disturbances by matching the experimental data with virtual height and echo amplitude obtained from a simple model of the disturbed ionosphere. Several data records analyzed in this manner indicate speeds of 400 to 680 m/sec and a direction of propagation from north to south. The digital ionosonde collects virtual height data with a time resolution of 10 sec and a height resolution of less than 300 m.
Chirico, Peter G.; Malpeli, Katherine C.; Trimble, Sarah M.
2012-01-01
This study compares the ASTER Global DEM version 1 (GDEMv1) and version 2 (GDEMv2) for two study sites with distinct terrain and land cover characteristics in western Africa. The effects of land cover, slope, relief, and stack number are evaluated through both absolute and relative DEM statistical comparisons. While GDEMv2 at times performed better than GDEMv1, this improvement was not consistent, revealing the complex nature and interaction of terrain and land cover characteristics, which influences the accuracy of GDEM tiles on local and regional scales.
All-digital pulse-expansion-based CMOS digital-to-time converter.
Chen, Chun-Chi; Chu, Che-Hsun
2017-02-01
This paper presents a new all-digital CMOS digital-to-time converter (DTC) based on pulse expansion. Pulse expansion is achieved using an all-digital pulse-mixing scheme that can effectively improve the timing resolution and enable the DTC to be concise. Without requiring the Vernier principle or a costly digital-to-analog converter, the DTC comprises a pulse generator for generating a pulse, a pulse-expanding circuit (PEC) for programming timing generation, and a time subtractor for removing the time width of the pulse. The PEC comprises only a delay chain composed of proposed pulse-expanding units and a multiplexer. For accuracy enhancement, a pulse neutralization technique is presented to eliminate undesirable pulse variation. A 4-bit converter was fabricated in a 0.35-μm Taiwan Semiconductor Manufacturing Company CMOS process and had a small area of nearly 0.045 mm 2 . Six chips were tested, all of which exhibited an improved resolution (approximately 16 ps) and low integral nonlinearity (less than ±0.4 least significant bit). The power consumption was 0.2 mW when the sample rate was 1M samples/s and the voltage supply was 3.3 V. The proposed DTC not only has favorable cost and power but also achieves an acceptable resolution without requiring an advanced CMOS process. This study is the first to use pulse expansion in digital-to-time conversion.
All-digital pulse-expansion-based CMOS digital-to-time converter
NASA Astrophysics Data System (ADS)
Chen, Chun-Chi; Chu, Che-Hsun
2017-02-01
This paper presents a new all-digital CMOS digital-to-time converter (DTC) based on pulse expansion. Pulse expansion is achieved using an all-digital pulse-mixing scheme that can effectively improve the timing resolution and enable the DTC to be concise. Without requiring the Vernier principle or a costly digital-to-analog converter, the DTC comprises a pulse generator for generating a pulse, a pulse-expanding circuit (PEC) for programming timing generation, and a time subtractor for removing the time width of the pulse. The PEC comprises only a delay chain composed of proposed pulse-expanding units and a multiplexer. For accuracy enhancement, a pulse neutralization technique is presented to eliminate undesirable pulse variation. A 4-bit converter was fabricated in a 0.35-μ m Taiwan Semiconductor Manufacturing Company CMOS process and had a small area of nearly 0.045 mm2. Six chips were tested, all of which exhibited an improved resolution (approximately 16 ps) and low integral nonlinearity (less than ±0.4 least significant bit). The power consumption was 0.2 mW when the sample rate was 1M samples/s and the voltage supply was 3.3 V. The proposed DTC not only has favorable cost and power but also achieves an acceptable resolution without requiring an advanced CMOS process. This study is the first to use pulse expansion in digital-to-time conversion.
Quantitative Secondary Electron Detector (QSED)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nayak, Subu; Joy, David C.
2013-12-31
Research is proposed to investigate the feasibility of applying recent advances in semiconductor technology to fabricate direct digital Quantitative Secondary Electron Detectors (QSED) for scanning electron microscopes (SEMs). If successful, commercial versions of the QSED would transform the SEM into a quantitative, metrological system with enhanced capabilities that, in turn, would broaden research horizons across industries. This project will be conducted in collaboration with Dr. David C Joy at the University of Tennessee, who has demonstrated limited (to the 1keV range) digital collection of the energy from backscattered signals in a SEM using a modified silicon drift detector. Several detectormore » configurations will be fabricated and tested for sensitivities, background noise reduction, DC offset elimination, and metrological capabilities (linearity, accuracy, etc.) against a set of commercially important performance criteria to ascertain concept feasibility. Once feasibility is proven, the solid state digital device array and its switching frequency will be scaled-up, in Phase II, to improve temporal resolution. If successful, this work will produce a crucial advancement in electron microscopy with wide-ranging applications. The following are key advantages anticipated from direct digital QSED: 1. High signal-to-noise ratio will improve SEM resolution in nano-scale, which is critical for dimensional metrology in any application. 2. Quantitative measurement will enhance process control and design validation in semiconductors, photo-voltaics, bio-medical devices and catalysts; and will improve accuracy in predicting the reliability and the lifecycle of materials across industries. 3. Video and dynamic-imaging capabilities will advance study in nano-scale phenomena in a variety of industries, including pharmaceutical and semiconductor materials. 4. Lower cost will make high-performing electron microscopes affordable to more researchers. 5. Compact size and ease of integration with imaging software will enable customers to retrofit and upgrade existing SEM equipment. ScienceTomorrow’s direct digital QSED concept has generated enthusiastic interest among a number of microscope makers, service companies, and microscope users. The company has offers of support from several companies. The roles these companies would play in supporting the project are described in the proposal. The proposed QSED advance sits squarely in the middle of ScienceTomorrow’s mission to provide next-generation technology solutions to today’s critical problems and, if successful, will further the company’s business strategy by launching an advanced, high-margin product that will enable the company and its partners to create at least 17 net-new jobs by the end of 2018.« less
Hard copies for digital medical images: an overview
NASA Astrophysics Data System (ADS)
Blume, Hartwig R.; Muka, Edward
1995-04-01
This paper is a condensed version of an invited overview on the technology of film hard-copies used in radiology. Because the overview was given to an essentially nonmedical audience, the reliance on film hard-copies in radiology is outlined in greater detail. The overview is concerned with laser image recorders generating monochrome prints on silver-halide films. The basic components of laser image recorders are sketched. The paper concentrates on the physical parameters - characteristic function, dynamic range, digitization resolution, modulation transfer function, and noise power spectrum - which define image quality and information transfer capability of the printed image. A preliminary approach is presented to compare the printed image quality with noise in the acquired image as well as with the noise of state-of- the-art cathode-ray-tube display systems. High-performance laser-image- recorder/silver-halide-film/light-box systems are well capable of reproducing acquired radiologic information. Most recently development was begun toward a display function standard for soft-copy display systems to facilitate similarity of image presentation between different soft-copy displays as well as between soft- and hard-copy displays. The standard display function is based on perceptional linearization. The standard is briefly reviewed to encourage the printer industry to adopt it, too.
NASA Astrophysics Data System (ADS)
Garcia-Sucerquia, J.; Xu, W.; Jericho, S. K.; Jericho, M. H.; Tamblyn, I.; Kreuzer, H. J.
2006-01-01
In recent years, in-line holography as originally proposed by Gabor, supplemented with numerical reconstruction, has been perfected to the point at which wavelength resolution both laterally and in depth is routinely achieved with light by using digital in-line holographic microscopy (DIHM). The advantages of DIHM are: (1) simplicity of the hardware (laser- pinhole-CCD camera), (2) magnification is obtained in the numerical reconstruction, (3) maximum information of the 3-D structure with a depth of field of millimeters, (4) changes in the specimen and the simultaneous motion of many species, can be followed in 4-D at the camera frame rate. We present results obtained with DIHM in biological and microfluidic applications. By taking advantage of the large depth of field and the plane-to-plane reconstruction capability of DIHM, we can produce 3D representations of the paths followed by micron-sized objects such as suspensions of microspheres and biological samples (cells, algae, protozoa, bacteria). Examples from biology include a study of the motion of bacteria in a diatom and the track of algae and paramecium. In microfluidic applications we observe micro-channel flow, motion of bubbles in water and evolution in electrolysis. The paper finishes with new results from an underwater version of DIHM.
High efficiency conical scanner for earth resources applications
NASA Technical Reports Server (NTRS)
Bates, J. C.; Dumas, H. J., Jr.
1975-01-01
A description is given of a six-arm conical scanner which was selected to provide a continuous line-of-sight scan. Two versions of the instrument are considered. The two versions differ in their weight. The weight of the heavy version is 600 lbs. A light weight design which employs beryllium and aluminum optical components weighs only 350 lbs. A multiplexer and analog-to-digital converter are to be incorporated into the design. Questions of instrument performance are also discussed.
Spatial resolution requirements for soft-copy reporting in digital radiography
NASA Astrophysics Data System (ADS)
Davies, Andrew G.; Cowen, Arnold R.; Fowler, Richard C.; Bury, Robert F.; Parkin, Geoff J. S.; Lintott, David J.; Martinez, Delia; Safudim, Asif
1996-04-01
The issue of the spatial resolution required in order to present diagnostic quality digital images, especially for softcopy reporting, has received much attention over recent years. The aim of this study was to compare the diagnostic performance reporting from hardcopy and optimized softcopy image presentations. One-hundred-fifteen radiographs of the hand acquired on a photostimulable phosphor computed radiography (CR) system were chosen as the image material. The study group was taken from patients who demonstrated subtle erosions of the bone in the digits. The control group consisted of radiologically normal bands. The images were presented in three modes, the CR system's hardcopy output, and softcopy presentations at full and half spatial resolutions. Four consultant radiologists participated as observers. Results were analyzed using the receiver operating characteristic (ROC) technique, and showed a statistically significant improvement in observer performance for both softcopy formats, when compared to the hardcopy presentation. However, no significant difference in observer performance was found between the two softcopy presentations. We therefore conclude that, with appropriate attention to the processing and presentation of digital image data, softcopy reporting can, for most examinations, provide superior diagnostic performance, even for images viewed at modest (1 k2) resolutions.
A Subsystem Test Bed for Chinese Spectral Radioheliograph
NASA Astrophysics Data System (ADS)
Zhao, An; Yan, Yihua; Wang, Wei
2014-11-01
The Chinese Spectral Radioheliograph is a solar dedicated radio interferometric array that will produce high spatial resolution, high temporal resolution, and high spectral resolution images of the Sun simultaneously in decimetre and centimetre wave range. Digital processing of intermediate frequency signal is an important part in a radio telescope. This paper describes a flexible and high-speed digital down conversion system for the CSRH by applying complex mixing, parallel filtering, and extracting algorithms to process IF signal at the time of being designed and incorporates canonic-signed digit coding and bit-plane method to improve program efficiency. The DDC system is intended to be a subsystem test bed for simulation and testing for CSRH. Software algorithms for simulation and hardware language algorithms based on FPGA are written which use less hardware resources and at the same time achieve high performances such as processing high-speed data flow (1 GHz) with 10 MHz spectral resolution. An experiment with the test bed is illustrated by using geostationary satellite data observed on March 20, 2014. Due to the easy alterability of the algorithms on FPGA, the data can be recomputed with different digital signal processing algorithms for selecting optimum algorithm.
The National Map - Orthoimagery
Mauck, James; Brown, Kim; Carswell, William J.
2009-01-01
Orthorectified digital aerial photographs and satellite images of 1-meter (m) pixel resolution or finer make up the orthoimagery component of The National Map. The process of orthorectification removes feature displacements and scale variations caused by terrain relief and sensor geometry. The result is a combination of the image characteristics of an aerial photograph or satellite image and the geometric qualities of a map. These attributes allow users to: *Measure distance *Calculate areas *Determine shapes of features *Calculate directions *Determine accurate coordinates *Determine land cover and use *Perform change detection *Update maps The standard digital orthoimage is a 1-m or finer resolution, natural color or color infra-red product. Most are now produced as GeoTIFFs and accompanied by a Federal Geographic Data Committee (FGDC)-compliant metadata file. The primary source for 1-m data is the National Agriculture Imagery Program (NAIP) leaf-on imagery. The U.S. Geological Survey (USGS) utilizes NAIP imagery as the image layer on its 'Digital- Map' - a new generation of USGS topographic maps (http://nationalmap.gov/digital_map). However, many Federal, State, and local governments and organizations require finer resolutions to meet a myriad of needs. Most of these images are leaf-off, natural-color products at resolutions of 1-foot (ft) or finer.
Digital Fresnel reflection holography for high-resolution 3D near-wall flow measurement.
Kumar, S Santosh; Hong, Jiarong
2018-05-14
We propose a novel backscatter holographic imaging system, as a compact and effective tool for 3D near-wall flow diagnostics at high resolutions, utilizing light reflected at the solid-liquid interface as a reference beam. The technique is fully calibrated, and is demonstrated in a densely seeded channel to achieve a spatial resolution of near-wall flows equivalent to or exceeding prior digital inline holographic measurements using local tracer seeding technique. Additionally, we examined the effects of seeding concentration and laser coherence on the measurement resolution and sample volume resolved, demonstrating the potential to manipulate sample domain by tuning the laser coherence profile.
Picosecond Resolution Time-to-Digital Converter Using Gm-C Integrator and SAR-ADC
NASA Astrophysics Data System (ADS)
Xu, Zule; Miyahara, Masaya; Matsuzawa, Akira
2014-04-01
A picosecond resolution time-to-digital converter (TDC) is presented. The resolution of a conventional delay chain TDC is limited by the delay of a logic buffer. Various types of recent TDCs are successful in breaking this limitation, but they require a significant calibration effort to achieve picosecond resolution with a sufficient linear range. To address these issues, we propose a simple method to break the resolution limitation without any calibration: a Gm-C integrator followed by a successive approximation register analog-to-digital converter (SAR-ADC). This translates the time interval into charge, and then the charge is quantized. A prototype chip was fabricated in 90 nm CMOS. The measurement results reveal a 1 ps resolution, a -0.6/0.7 LSB differential nonlinearity (DNL), a -1.1/2.3 LSB integral nonlinearity (INL), and a 9-bit range. The measured 11.74 ps single-shot precision is caused by the noise of the integrator. We analyze the noise of the integrator and propose an improved front-end circuit to reduce this noise. The proposal is verified by simulations showing the maximum single-shot precision is less than 1 ps. The proposed front-end circuit can also diminish the mismatch effects.
The effect of horizontal resolution on simulation quality in the Community Atmospheric Model, CAM5.1
Wehner, Michael F.; Reed, Kevin A.; Li, Fuyu; ...
2014-10-13
We present an analysis of version 5.1 of the Community Atmospheric Model (CAM5.1) at a high horizontal resolution. Intercomparison of this global model at approximately 0.25°, 1°, and 2° is presented for extreme daily precipitation as well as for a suite of seasonal mean fields. In general, extreme precipitation amounts are larger in high resolution than in lower-resolution configurations. In many but not all locations and/or seasons, extreme daily precipitation rates in the high-resolution configuration are higher and more realistic. The high-resolution configuration produces tropical cyclones up to category 5 on the Saffir-Simpson scale and a comparison to observations revealsmore » both realistic and unrealistic model behavior. In the absence of extensive model tuning at high resolution, simulation of many of the mean fields analyzed in this study is degraded compared to the tuned lower-resolution public released version of the model.« less
NASA Astrophysics Data System (ADS)
Wacyk, Ihor; Prache, Olivier; Ghosh, Amal
2011-06-01
AMOLED microdisplays continue to show improvement in resolution and optical performance, enhancing their appeal for a broad range of near-eye applications such as night vision, simulation and training, situational awareness, augmented reality, medical imaging, and mobile video entertainment and gaming. eMagin's latest development of an HDTV+ resolution technology integrates an OLED pixel of 3.2 × 9.6 microns in size on a 0.18 micron CMOS backplane to deliver significant new functionality as well as the capability to implement a 1920×1200 microdisplay in a 0.86" diagonal area. In addition to the conventional matrix addressing circuitry, the HDTV+ display includes a very lowpower, low-voltage-differential-signaling (LVDS) serialized interface to minimize cable and connector size as well as electromagnetic emissions (EMI), an on-chip set of look-up-tables for digital gamma correction, and a novel pulsewidth- modulation (PWM) scheme that together with the standard analog control provides a total dimming range of 0.05cd/m2 to 2000cd/m2 in the monochrome version. The PWM function also enables an impulse drive mode of operation that significantly reduces motion artifacts in high speed scene changes. An internal 10-bit DAC ensures that a full 256 gamma-corrected gray levels are available across the entire dimming range, resulting in a measured dynamic range exceeding 20-bits. This device has been successfully tested for operation at frame rates ranging from 30Hz up to 85Hz. This paper describes the operational features and detailed optical and electrical test results for the new AMOLED WUXGA resolution microdisplay.
Improved-resolution real-time skin-dose mapping for interventional fluoroscopic procedures
NASA Astrophysics Data System (ADS)
Rana, Vijay K.; Rudin, Stephen; Bednarek, Daniel R.
2014-03-01
We have developed a dose-tracking system (DTS) that provides a real-time display of the skin-dose distribution on a 3D patient graphic during fluoroscopic procedures. Radiation dose to individual points on the skin is calculated using exposure and geometry parameters from the digital bus on a Toshiba C-arm unit. To accurately define the distribution of dose, it is necessary to use a high-resolution patient graphic consisting of a large number of elements. In the original DTS version, the patient graphics were obtained from a library of population body scans which consisted of larger-sized triangular elements resulting in poor congruence between the graphic points and the x-ray beam boundary. To improve the resolution without impacting real-time performance, the number of calculations must be reduced and so we created software-designed human models and modified the DTS to read the graphic as a list of vertices of the triangular elements such that common vertices of adjacent triangles are listed once. Dose is calculated for each vertex point once instead of the number of times that a given vertex appears in multiple triangles. By reformatting the graphic file, we were able to subdivide the triangular elements by a factor of 64 times with an increase in the file size of only 1.3 times. This allows a much greater number of smaller triangular elements and improves resolution of the patient graphic without compromising the real-time performance of the DTS and also gives a smoother graphic display for better visualization of the dose distribution.
36 CFR 1237.26 - What materials and processes must agencies use to create audiovisual records?
Code of Federal Regulations, 2011 CFR
2011-07-01
...) If using reversal type processing, require full photographic reversal; i.e., develop, bleach, expose...-digital or scanned digital images that are scheduled as permanent or unscheduled, a record (or master) version of each image must be comparable in quality to a 35 mm film photograph or better, and must be...
36 CFR 1237.26 - What materials and processes must agencies use to create audiovisual records?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) If using reversal type processing, require full photographic reversal; i.e., develop, bleach, expose...-digital or scanned digital images that are scheduled as permanent or unscheduled, a record (or master) version of each image must be comparable in quality to a 35 mm film photograph or better, and must be...
36 CFR § 1237.26 - What materials and processes must agencies use to create audiovisual records?
Code of Federal Regulations, 2013 CFR
2013-07-01
... recommendations. (3) If using reversal type processing, require full photographic reversal; i.e., develop, bleach...-digital or scanned digital images that are scheduled as permanent or unscheduled, a record (or master) version of each image must be comparable in quality to a 35 mm film photograph or better, and must be...
36 CFR 1237.26 - What materials and processes must agencies use to create audiovisual records?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) If using reversal type processing, require full photographic reversal; i.e., develop, bleach, expose...-digital or scanned digital images that are scheduled as permanent or unscheduled, a record (or master) version of each image must be comparable in quality to a 35 mm film photograph or better, and must be...
36 CFR 1237.26 - What materials and processes must agencies use to create audiovisual records?
Code of Federal Regulations, 2014 CFR
2014-07-01
...) If using reversal type processing, require full photographic reversal; i.e., develop, bleach, expose...-digital or scanned digital images that are scheduled as permanent or unscheduled, a record (or master) version of each image must be comparable in quality to a 35 mm film photograph or better, and must be...
Digital Skills Acquisition: Future Trends among Older Adults
ERIC Educational Resources Information Center
Gilliam, Brian K.
2011-01-01
Purpose: The purpose of this study was to identify future trends and barriers that will either facilitate or impede the narrowing of the digital skills divide among older adults during the next 10 years. Methodology: To address the research questions, this study used a modified version of the Delphi process using a panel of experts who…
Digital Gaming and Language Learning: Autonomy and Community
ERIC Educational Resources Information Center
Chik, Alice
2014-01-01
The relationship between digital game play and second language (L2) learning is a particularly tricky issue in East Asia. Though there is an emerging presence of Chinese online games, many more young people are playing the English- or Japanese-language versions of the most popular commercial off-the-shelf (COTS) video games. In other words, most…
Digital Photography and Its Impact on Instruction.
ERIC Educational Resources Information Center
Lantz, Chris
Today the chemical processing of film is being replaced by a virtual digital darkroom. Digital image storage makes new levels of consistency possible because its nature is less volatile and more mutable than traditional photography. The potential of digital imaging is great, but issues of disk storage, computer speed, camera sensor resolution,…
NASA Astrophysics Data System (ADS)
Khaleghi, Morteza; Furlong, Cosme; Cheng, Jeffrey Tao; Rosowski, John J.
2014-07-01
The eardrum or Tympanic Membrane (TM) transfers acoustic energy from the ear canal (at the external ear) into mechanical motions of the ossicles (at the middle ear). The acousto-mechanical-transformer behavior of the TM is determined by its shape and mechanical properties. For a better understanding of hearing mysteries, full-field-of-view techniques are required to quantify shape, nanometer-scale sound-induced displacement, and mechanical properties of the TM in 3D. In this paper, full-field-of-view, three-dimensional shape and sound-induced displacement of the surface of the TM are obtained by the methods of multiple wavelengths and multiple sensitivity vectors with lensless digital holography. Using our developed digital holographic systems, unique 3D information such as, shape (with micrometer resolution), 3D acoustically-induced displacement (with nanometer resolution), full strain tensor (with nano-strain resolution), 3D phase of motion, and 3D directional cosines of the displacement vectors can be obtained in full-field-ofview with a spatial resolution of about 3 million points on the surface of the TM and a temporal resolution of 15 Hz.
Bolm, Karen S.
2002-01-01
The map area is located in southeastern Arizona. This report describes the map units, the methods used to convert the geologic map data into a digital format, and the ArcInfo GIS file structures and relationships; and it explains how to download the digital files from the U.S. Geological Survey public access World Wide Web site on the Internet. See figures 2 and 3 for page-size versions of the map compilation.
Variability along the Atlantic water pathway in the forced Norwegian Earth System Model
NASA Astrophysics Data System (ADS)
Langehaug, H. R.; Sandø, A. B.; Årthun, M.; Ilıcak, M.
2018-03-01
The growing attention on mechanisms that can provide predictability on interannual-to-decadal time scales, makes it necessary to identify how well climate models represent such mechanisms. In this study we use a high (0.25° horizontal grid) and a medium (1°) resolution version of a forced global ocean-sea ice model, utilising the Norwegian Earth System Model, to assess the impact of increased ocean resolution. Our target is the simulation of temperature and salinity anomalies along the pathway of warm Atlantic water in the subpolar North Atlantic and the Nordic Seas. Although the high resolution version has larger biases in general at the ocean surface, the poleward propagation of thermohaline anomalies is better resolved in this version, i.e., the time for an anomaly to travel northward is more similar to observation based estimates. The extent of these anomalies can be rather large in both model versions, as also seen in observations, e.g., stretching from Scotland to northern Norway. The easternmost branch into the Nordic and Barents Seas, carrying warm Atlantic water, is also improved by higher resolution, both in terms of mean heat transport and variability in thermohaline properties. A more detailed assessment of the link between the North Atlantic Ocean circulation and the thermohaline anomalies at the entrance of the Nordic Seas reveals that the high resolution is more consistent with mechanisms that are previously published. This suggests better dynamics and variability in the subpolar region and the Nordic Seas in the high resolution compared to the medium resolution. This is most likely due a better representation of the mean circulation in the studied region when using higher resolution. As the poleward propagation of ocean heat anomalies is considered to be a key source of climate predictability, we recommend that similar methodology presented herein should be performed on coupled climate models that are used for climate prediction.
NASA Astrophysics Data System (ADS)
Kendrick, Stephen E.; Harwit, Alex; Kaplan, Michael; Smythe, William D.
2007-09-01
An MWIR TDI (Time Delay and Integration) Imager and Spectrometer (MTIS) instrument for characterizing from orbit the moons of Jupiter and Saturn is proposed. Novel to this instrument is the planned implementation of a digital TDI detector array and an innovative imaging/spectroscopic architecture. Digital TDI enables a higher SNR for high spatial resolution surface mapping of Titan and Enceladus and for improved spectral discrimination and resolution at Europa. The MTIS imaging/spectroscopic architecture combines a high spatial resolution coarse wavelength resolution imaging spectrometer with a hyperspectral sensor to spectrally decompose a portion of the data adjacent to the data sampled in the imaging spectrometer. The MTIS instrument thus maps with high spatial resolution a planetary object while spectrally decomposing enough of the data that identification of the constituent materials is highly likely. Additionally, digital TDI systems have the ability to enable the rejection of radiation induced spikes in high radiation environments (Europa) and the ability to image in low light levels (Titan and Enceladus). The ability to image moving objects that might be missed utilizing a conventional TDI system is an added advantage and is particularly important for characterizing atmospheric effects and separating atmospheric and surface components. This can be accomplished with on-orbit processing or collecting and returning individual non co-added frames.
Observer performance assessment of JPEG-compressed high-resolution chest images
NASA Astrophysics Data System (ADS)
Good, Walter F.; Maitz, Glenn S.; King, Jill L.; Gennari, Rose C.; Gur, David
1999-05-01
The JPEG compression algorithm was tested on a set of 529 chest radiographs that had been digitized at a spatial resolution of 100 micrometer and contrast sensitivity of 12 bits. Images were compressed using five fixed 'psychovisual' quantization tables which produced average compression ratios in the range 15:1 to 61:1, and were then printed onto film. Six experienced radiologists read all cases from the laser printed film, in each of the five compressed modes as well as in the non-compressed mode. For comparison purposes, observers also read the same cases with reduced pixel resolutions of 200 micrometer and 400 micrometer. The specific task involved detecting masses, pneumothoraces, interstitial disease, alveolar infiltrates and rib fractures. Over the range of compression ratios tested, for images digitized at 100 micrometer, we were unable to demonstrate any statistically significant decrease (p greater than 0.05) in observer performance as measured by ROC techniques. However, the observers' subjective assessments of image quality did decrease significantly as image resolution was reduced and suggested a decreasing, but nonsignificant, trend as the compression ratio was increased. The seeming discrepancy between our failure to detect a reduction in observer performance, and other published studies, is likely due to: (1) the higher resolution at which we digitized our images; (2) the higher signal-to-noise ratio of our digitized films versus typical CR images; and (3) our particular choice of an optimized quantization scheme.
Resolution enhancement in digital holography by self-extrapolation of holograms.
Latychevskaia, Tatiana; Fink, Hans-Werner
2013-03-25
It is generally believed that the resolution in digital holography is limited by the size of the captured holographic record. Here, we present a method to circumvent this limit by self-extrapolating experimental holograms beyond the area that is actually captured. This is done by first padding the surroundings of the hologram and then conducting an iterative reconstruction procedure. The wavefront beyond the experimentally detected area is thus retrieved and the hologram reconstruction shows enhanced resolution. To demonstrate the power of this concept, we apply it to simulated as well as experimental holograms.
NASA Technical Reports Server (NTRS)
Pawson, S.; Stolarski, R.S.; Nielsen, J.E.; Perlwitz, J.; Oman, L.; Waugh, D.
2009-01-01
This study will document the behavior of the polar vortices in two versions of the GEOS CCM. Both versions of the model include the same stratospheric chemistry, They differ in the underlying circulation model. Version 1 of the GEOS CCM is based on the Goddard Earth Observing System, Version 4, general circulation model which includes the finite-volume (Lin-Rood) dynamical core and physical parameterizations from Community Climate Model, Version 3. GEOS CCM Version 2 is based on the GEOS-5 GCM that includes a different tropospheric physics package. Baseline simulations of both models, performed at two-degree spatial resolution, show some improvements in Version 2, but also some degradation, In the Antarctic, both models show an over-persistent stratospheric polar vortex with late breakdown, but the year-to-year variations that are overestimated in Version I are more realistic in Version 2. The implications of this for the interactions with tropospheric climate, the Southern Annular Mode, will be discussed. In the Arctic both model versions show a dominant dynamically forced variabi;ity, but Version 2 has a persistent warm bias in the low stratosphere and there are seasonal differences in the simulations. These differences will be quantified in terms of climate change and ozone loss. Impacts of model resolution, using simulations at one-degree and half-degree, and changes in physical parameterizations (especially the gravity wave drag) will be discussed.
NASA Technical Reports Server (NTRS)
Neiner, G. H.; Cole, G. L.; Arpasi, D. J.
1972-01-01
Digital computer control of a mixed-compression inlet is discussed. The inlet was terminated with a choked orifice at the compressor face station to dynamically simulate a turbojet engine. Inlet diffuser exit airflow disturbances were used. A digital version of a previously tested analog control system was used for both normal shock and restart control. Digital computer algorithms were derived using z-transform and finite difference methods. Using a sample rate of 1000 samples per second, the digital normal shock and restart controls essentially duplicated the inlet analog computer control results. At a sample rate of 100 samples per second, the control system performed adequately but was less stable.
NASA Astrophysics Data System (ADS)
Howe, Michael
2014-05-01
Much of the digital geological information on the composition, properties and dynamics of the subsurface is based ultimately on physical samples, many of which are archived to provide a basis for the information. Online metadata catalogues of these collections have now been available for many years. Many of these are institutional and tightly focussed, with UK examples including the British Geological Survey's (BGS) palaeontological samples database, PalaeoSaurus (http://www.bgs.ac.uk/palaeosaurus/), and mineralogical and petrological sample database, Britrocks (http://www.bgs.ac.uk/data/britrocks.html) . There are now a growing number of international sample metadata databases, including The Palaeobiology Database (http://paleobiodb.org/) and SESAR, the IGSN (International Geo Sample Number) database (http://www.geosamples.org/catalogsearch/ ). More recently the emphasis has moved beyond metadata (locality, identification, age, citations, etc) to digital imagery, with the intention of providing the user with at least enough information to determine whether viewing the sample would be worthwhile. Recent BGS examples include high resolution (e.g. 7216 x 5412 pixel) hydrocarbon well core images (http://www.bgs.ac.uk/data/offshoreWells/wells.cfc?method=searchWells) , high resolution rock thin section images (e.g. http://www.largeimages.bgs.ac.uk/iip/britrocks.html?id=290000/291739 ) and building stone images (http://geoscenic.bgs.ac.uk/asset-bank/action/browseItems?categoryId=1547&categoryTypeId=1) . This has been developed further with high resolution stereo images. The Jisc funded GB3D type fossils online project delivers these as red-cyan anaglyphs (http://www.3d-fossils.ac.uk/). More innovatively, the GB3D type fossils project has laser scanned several thousand type fossils and the resulting 3d-digital models are now being delivered through the online portal. Importantly, this project also represents collaboration between the BGS, Oxford and Cambridge Universities, the National Museums of Wales, and numerous other national, local and regional museums. The lack of currently accepted international standards and infrastructures for the delivery of high resolution images and 3d-digital models has necessitated the BGS in developing or selecting its own. Most high resolution images have been delivered using the JPEG 2000 format because of its quality and speed. Digital models have been made available in both .PLY and .OBJ format because of their respective efficient file size, and flexibility. Consideration must now be given to European and international standards and infrastructures for the delivery of high resolution images and 3d-digital models.
charged tracks or associated with photons or neutral hadrons. Hardware effort: A Digital Hadron fine segmentation, the energy resolution for single hadrons is preserved with a simple digital readout Physics Division Digital Hadron Calorimeter with RPCs (US effort) CALICE Collaboration American Linear
Improvement of the energy resolution via an optimized digital signal processing in GERDA Phase I
Agostini, M.; Allardt, M.; Bakalyarov, A. M.; ...
2015-06-09
An optimized digital shaping filter has been developed for the Gerda experiment which searches for neutrinoless double beta decay inmore » $$^{76}$$Ge. The Gerda Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) corresponding to 10% at the $Q$ value for $$0\
High-resolution digital brain atlases: a Hubble telescope for the brain.
Jones, Edward G; Stone, James M; Karten, Harvey J
2011-05-01
We describe implementation of a method for digitizing at microscopic resolution brain tissue sections containing normal and experimental data and for making the content readily accessible online. Web-accessible brain atlases and virtual microscopes for online examination can be developed using existing computer and internet technologies. Resulting databases, made up of hierarchically organized, multiresolution images, enable rapid, seamless navigation through the vast image datasets generated by high-resolution scanning. Tools for visualization and annotation of virtual microscope slides enable remote and universal data sharing. Interactive visualization of a complete series of brain sections digitized at subneuronal levels of resolution offers fine grain and large-scale localization and quantification of many aspects of neural organization and structure. The method is straightforward and replicable; it can increase accessibility and facilitate sharing of neuroanatomical data. It provides an opportunity for capturing and preserving irreplaceable, archival neurohistological collections and making them available to all scientists in perpetuity, if resources could be obtained from hitherto uninterested agencies of scientific support. © 2011 New York Academy of Sciences.
Right main bronchial fracture resolution by digital thoracic drainage system.
Cortés Julián, Gildardo; Mier, José M; Iñiguez, Marco A; Guzmán de Alba, Enrique
2016-03-01
Tracheobronchial stenosis is common in the thoracic surgery service, and iatrogenic injury of the airway after manipulation is not infrequent. When a digital thoracic drainage system came onto the market, many advantages were evident. A 24-year-old woman with critical right main bronchial stenosis underwent airway dilation that was complicated by a tear with a massive air leak, resulting in a total right pneumothorax. We employed a pleural drain connected to a digital thoracic drainage system. The drain was removed 2 days after successful resolution of the air leak. © The Author(s) 2015.
Space Shuttle Orbiter Digital Outer Mold Line Scanning
NASA Technical Reports Server (NTRS)
Campbell, Charles H.; Wilson, Brad; Pavek, Mike; Berger, Karen
2012-01-01
The Space Shuttle Orbiters Discovery and Endeavor have been digitally scanned to produce post-flight configuration outer mold line surfaces. Very detailed scans of the windward side of these vehicles provide resolution of the detailed tile step and gap geometry, as well as the reinforced carbon carbon nose cap and leading edges. Lower resolution scans of the upper surface provide definition of the crew cabin windows, wing upper surfaces, payload bay doors, orbital maneuvering system pods and the vertical tail. The process for acquisition of these digital scans as well as post-processing of the very large data set will be described.
Avionic Data Bus Integration Technology
1991-12-01
address the hardware-software interaction between a digital data bus and an avionic system. Very Large Scale Integration (VLSI) ICs and multiversion ...the SCP. In 1984, the Sperry Corporation developed a fault tolerant system which employed multiversion programming, voting, and monitoring for error... MULTIVERSION PROGRAMMING. N-version programming. 226 N-VERSION PROGRAMMING. The independent coding of a number, N, of redundant computer programs that
Staudacher, Ingo; Nalpathamkalam, Asha Roy; Uhlmann, Lorenz; Illg, Claudius; Seehausen, Sebastian; Akhavanpoor, Mohammadreza; Buchauer, Anke; Geis, Nicolas; Lugenbiel, Patrick; Schweizer, Patrick A; Xynogalos, Panagiotis; Zylla, Maura M; Scholz, Eberhard; Zitron, Edgar; Katus, Hugo A; Thomas, Dierk
2017-10-11
Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect ® ) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician's workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort.
Camera system resolution and its influence on digital image correlation
Reu, Phillip L.; Sweatt, William; Miller, Timothy; ...
2014-09-21
Digital image correlation (DIC) uses images from a camera and lens system to make quantitative measurements of the shape, displacement, and strain of test objects. This increasingly popular method has had little research on the influence of the imaging system resolution on the DIC results. This paper investigates the entire imaging system and studies how both the camera and lens resolution influence the DIC results as a function of the system Modulation Transfer Function (MTF). It will show that when making spatial resolution decisions (including speckle size) the resolution limiting component should be considered. A consequence of the loss ofmore » spatial resolution is that the DIC uncertainties will be increased. This is demonstrated using both synthetic and experimental images with varying resolution. The loss of image resolution and DIC accuracy can be compensated for by increasing the subset size, or better, by increasing the speckle size. The speckle-size and spatial resolution are now a function of the lens resolution rather than the more typical assumption of the pixel size. The study will demonstrate the tradeoffs associated with limited lens resolution.« less
NASA Astrophysics Data System (ADS)
Zhang, Yibo; Wu, Yichen; Zhang, Yun; Ozcan, Aydogan
2017-03-01
Digital pathology and telepathology require imaging tools with high-throughput, high-resolution and accurate color reproduction. Lens-free on-chip microscopy based on digital in-line holography is a promising technique towards these needs, as it offers a wide field of view (FOV >20 mm2) and high resolution with a compact, low-cost and portable setup. Color imaging has been previously demonstrated by combining reconstructed images at three discrete wavelengths in the red, green and blue parts of the visible spectrum, i.e., the RGB combination method. However, this RGB combination method is subject to color distortions. To improve the color performance of lens-free microscopy for pathology imaging, here we present a wavelet-based color fusion imaging framework, termed "digital color fusion microscopy" (DCFM), which digitally fuses together a grayscale lens-free microscope image taken at a single wavelength and a low-resolution and low-magnification color-calibrated image taken by a lens-based microscope, which can simply be a mobile phone based cost-effective microscope. We show that the imaging results of an H&E stained breast cancer tissue slide with the DCFM technique come very close to a color-calibrated microscope using a 40x objective lens with 0.75 NA. Quantitative comparison showed 2-fold reduction in the mean color distance using the DCFM method compared to the RGB combination method, while also preserving the high-resolution features of the lens-free microscope. Due to the cost-effective and field-portable nature of both lens-free and mobile-phone microscopy techniques, their combination through the DCFM framework could be useful for digital pathology and telepathology applications, in low-resource and point-of-care settings.
,
2000-01-01
The U.S. Geological Survey's (USGS) Earth Explorer Web site provides access to millions of land-related products, including the following: Satellite images from Landsat, advanced very high resolution radiometer (AVHRR), and Corona data sets. Aerial photographs from the National Aerial Photography Program, NASA, and USGS data sets. Digital cartographic data from digital elevation models, digital line graphs, digital raster graphics, and digital orthophoto quadrangles. USGS paper maps Digital, film, and paper products are available, and many products can be previewed before ordering.
ERIC Educational Resources Information Center
Loiseau, Mathieu; Cervini, Cristiana; Ceccherelli, Andrea; Masperi, Monica; Salomoni, Paola; Roccetti, Marco; Valva, Antonella; Bianco, Francesca
2016-01-01
In this paper, we present two versions of a learning game developed respectively at the Grenoble Alpes and Bologna University. This research focuses on a digital game aimed at favouring the learners' "playful attitude" and harnessing it towards "accuracy" aspects of language learning (lexicon and morphology, here). The game,…
Introducing AgilePQ DCM (Digital Conversion Module) - Video Text Version
monolith. There's not one thing you do to make things digitally secure. We talk in terms of confidentiality enable these nonfunctional attributes. There's not, as I said, one thing you can do to satisfy the whole subject of cyber security. And there's not one thing you can do to fully enable these nonfunctional
Use of Personal Digital Assistants (PDAs) in Reflection on Learning and Practice
ERIC Educational Resources Information Center
Ranson, Sonya L.; Boothby, John; Mazmanian, Paul E.; Alvanzo, Anika
2007-01-01
Introduction: As the use of personal digital assistants (PDAs) grows, the value of reflection of learning and practice draws increased attention from policymakers and evaluators. To learn more about the use of PDAs in practice and learning, the present study describes use of (1) PDAs in patient care and (2) a PDA version of the Virginia Board of…
NASA Technical Reports Server (NTRS)
Kriegler, F.; Marshall, R.; Lampert, S.; Gordon, M.; Cornell, C.; Kistler, R.
1973-01-01
The MIDAS system is a prototype, multiple-pipeline digital processor mechanizing the multivariate-Gaussian, maximum-likelihood decision algorithm operating at 200,000 pixels/second. It incorporates displays and film printer equipment under control of a general purpose midi-computer and possesses sufficient flexibility that operational versions of the equipment may be subsequently specified as subsets of the system.
The GEOS-5 Atmospheric General Circulation Model: Mean Climate and Development from MERRA to Fortuna
NASA Technical Reports Server (NTRS)
Molod, Andrea; Takacs, Lawrence; Suarez, Max; Bacmeister, Julio; Song, In-Sun; Eichmann, Andrew
2012-01-01
This report is a documentation of the Fortuna version of the GEOS-5 Atmospheric General Circulation Model (AGCM). The GEOS-5 AGCM is currently in use in the NASA Goddard Modeling and Assimilation Office (GMAO) for simulations at a wide range of resolutions, in atmosphere only, coupled ocean-atmosphere, and data assimilation modes. The focus here is on the development subsequent to the version that was used as part of NASA s Modern-Era Retrospective Analysis for Research and Applications (MERRA). We present here the results of a series of 30-year atmosphere-only simulations at different resolutions, with focus on the behavior of the 1-degree resolution simulation. The details of the changes in parameterizations subsequent to the MERRA model version are outlined, and results of a series of 30-year, atmosphere-only climate simulations at 2-degree resolution are shown to demonstrate changes in simulated climate associated with specific changes in parameterizations. The GEOS-5 AGCM presented here is the model used for the GMAO s atmosphere-only and coupled CMIP-5 simulations.
NASA Astrophysics Data System (ADS)
Garay, Michael J.; Kalashnikova, Olga V.; Bull, Michael A.
2017-04-01
Since early 2000, the Multi-angle Imaging SpectroRadiometer (MISR) instrument on NASA's Terra satellite has been acquiring data that have been used to produce aerosol optical depth (AOD) and particle property retrievals at 17.6 km spatial resolution. Capitalizing on the capabilities provided by multi-angle viewing, the current operational (Version 22) MISR algorithm performs well, with about 75 % of MISR AOD retrievals globally falling within 0.05 or 20 % × AOD of paired validation data from the ground-based Aerosol Robotic Network (AERONET). This paper describes the development and assessment of a prototype version of a higher-spatial-resolution 4.4 km MISR aerosol optical depth product compared against multiple AERONET Distributed Regional Aerosol Gridded Observations Network (DRAGON) deployments around the globe. In comparisons with AERONET-DRAGON AODs, the 4.4 km resolution retrievals show improved correlation (r = 0. 9595), smaller RMSE (0.0768), reduced bias (-0.0208), and a larger fraction within the expected error envelope (80.92 %) relative to the Version 22 MISR retrievals.
NASA Astrophysics Data System (ADS)
Garay, M. J.; Bull, M. A.; Witek, M. L.; Diner, D. J.; Seidel, F.
2017-12-01
Since early 2000, the Multi-angle Imaging SpectroRadiometer (MISR) instrument on NASA's Terra satellite has been providing operational Level 2 (swath-based) aerosol optical depth (AOD) and particle property retrievals at 17.6 km spatial resolution and atmospherically corrected land surface products at 1.1 km resolution. A major, multi-year development effort has led to the release of updated operational MISR Level 2 aerosol and land surface retrieval products. The spatial resolution of the aerosol product has been increased to 4.4 km, allowing more detailed characterization of aerosol spatial variability, especially near local sources and in urban areas. The product content has been simplified and updated to include more robust measures of retrieval uncertainty and other fields to benefit users. The land surface product has also been updated to incorporate the Version 23 aerosol product as input and to improve spatial coverage, particularly over mountainous terrain and snow/ice-covered surfaces. We will describe the major upgrades incorporated in Version 23, present validation of the aerosol product, and describe some of the applications enabled by these product updates.
Digitally enhanced GLORIA images for petroleum exploration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prindle, R.O.; Lanz, K
1990-05-01
This poster presentation graphically depicts the geological and structural information that can be derived from digitally enhanced Geological Long Range Inclined Asdic (GLORIA) sonar images. This presentation illustrates the advantages of scale enlargement as an interpreter's tool in an offshore area within the Eel River Basin, Northern California. Sonographs were produced from digital tapes originally collected for the exclusive economic zone (EEZ)-SCAN 1984 survey, which was published in the Atlas of the Western Conterminous US at a scale of 1:500,000. This scale is suitable for displaying regional offshore tectonic features but does not have the resolution required for detailed geologicalmore » mapping necessary for petroleum exploration. Applications of digital enhancing techniques which utilize contrast stretching and assign false colors to wide-swath sonar imagery (approximately 40 km) with 50-m resolution enables the acquisition and interpretation of significantly more geological and structural data. This, combined with a scale enlargement to 1:100,000 and high contrast contact prints vs. the offset prints of the atlas, increases the resolution and sharpness of bathymetric features so that many more subtle features may be mapped in detail. A tectonic interpretation of these digitally enhanced GLORIA sonographs from the Eel River basin is presented, displaying anticlines, lineaments, ridge axis, pathways of sediment flow, and subtle doming. Many of these features are not present on published bathymetric maps and have not been derived from seismic data because the plan view spatial resolution is much less than that available from the GLORIA imagery.« less
Performance of the Fully Digital FPGA-Based Front-End Electronics for the GALILEO Array
NASA Astrophysics Data System (ADS)
Barrientos, D.; Bellato, M.; Bazzacco, D.; Bortolato, D.; Cocconi, P.; Gadea, A.; González, V.; Gulmini, M.; Isocrate, R.; Mengoni, D.; Pullia, A.; Recchia, F.; Rosso, D.; Sanchis, E.; Toniolo, N.; Ur, C. A.; Valiente-Dobón, J. J.
2015-12-01
In this work we present the architecture and results of a fully digital Front End Electronics (FEE) read out system developed for the GALILEO array. The FEE system, developed in collaboration with the Advanced Gamma Tracking Array (AGATA) collaboration, is composed of three main blocks: preamplifiers, digitizers and preprocessing electronics. The slow control system contains a custom Linux driver, a dynamic library and a server implementing network services. This work presents the first results of the digital FEE system coupled with a GALILEO germanium detector, which has demonstrated the capability to achieve an energy resolution of 1.530/00 at an energy of 1.33 MeV, similar to the one obtained with a conventional analog system. While keeping a good performance in terms of energy resolution, digital electronics will allow to instrument the full GALILEO array with a versatile system with high integration and low power consumption and costs.
Cherepy, Nerine Jane; Payne, Stephen Anthony; Drury, Owen B; Sturm, Benjamin W
2014-11-11
A scintillator radiation detector system according to one embodiment includes a scintillator; and a processing device for processing pulse traces corresponding to light pulses from the scintillator, wherein pulse digitization is used to improve energy resolution of the system. A scintillator radiation detector system according to another embodiment includes a processing device for fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times and performing a direct integration of fit parameters. A method according to yet another embodiment includes processing pulse traces corresponding to light pulses from a scintillator, wherein pulse digitization is used to improve energy resolution of the system. A method in a further embodiment includes fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times; and performing a direct integration of fit parameters. Additional systems and methods are also presented.
NASA Astrophysics Data System (ADS)
Sutanudjaja, Edwin; van Beek, Rens; Winsemius, Hessel; Ward, Philip; Bierkens, Marc
2017-04-01
The Aqueduct Global Flood Analyzer, launched in 2015, is an open-access and free-of-charge web-based interactive platform which assesses and visualises current and future projections of river flood impacts across the globe. One of the key components in the Analyzer is a set of river flood inundation hazard maps derived from the global hydrological model simulation of PCR-GLOBWB. For the current version of the Analyzer, accessible on http://floods.wri.org/#/, the early generation of PCR-GLOBWB 1.0 was used and simulated at 30 arc-minute ( 50 km at the equator) resolution. In this presentation, we will show the new version of these hazard maps. This new version is based on the latest version of PCR-GLOBWB 2.0 (https://github.com/UU-Hydro/PCR-GLOBWB_model, Sutanudjaja et al., 2016, doi:10.5281/zenodo.60764) simulated at 5 arc-minute ( 10 km at the equator) resolution. The model simulates daily hydrological and water resource fluxes and storages, including the simulation of overbank volume that ends up on the floodplain (if flooding occurs). The simulation was performed for the present day situation (from 1960) and future climate projections (until 2099) using the climate forcing created in the ISI-MIP project. From the simulated flood inundation volume time series, we then extract annual maxima for each cell, and fit these maxima to a Gumbel extreme value distribution. This allows us to derive flood volume maps of any hazard magnitude (ranging from 2-year to 1000-year flood events) and for any time period (e.g. 1960-1999, 2010-2049, 2030-2069, and 2060-2099). The derived flood volumes (at 5 arc-minute resolution) are then spread over the high resolution terrain model using an updated GLOFRIS downscaling module (Winsemius et al., 2013, doi:10.5194/hess-17-1871-2013). The updated version performs a volume spreading sequentially from more upstream basins to downstream basins, hence enabling a better inclusion of smaller streams, and takes into account spreading of water over diverging deltaic regions. This results in a set of high resolution hazard maps of flood inundation depth at 30 arc-second ( 1 km at the equator) resolution. Together with many other updates and new features, the resulting flood hazard maps will be used in the next generation of the Aqueduct Global Flood Analyzer.
Digital disaster evaluation and its application to 2015 Ms 8.1 Nepal Earthquake
NASA Astrophysics Data System (ADS)
WANG, Xiaoqing; LV, Jinxia; DING, Xiang; DOU, Aixia
2016-11-01
The purpose of the article is to probe the technique resolution of disaster information extraction and evaluation from the digital RS images based on the internet environment and aided by the social and geographic information. The solution is composed with such methods that the fast post-disaster assessment system will assess automatically the disaster area and grade, the multi-phase satellite and airborne high resolution digital RS images will provide the basis to extract the disaster areas or spots, assisted by the fast position of potential serious damage risk targets according to the geographic, administrative, population, buildings and other information in the estimated disaster region, the 2D digital map system or 3D digital earth system will provide platforms to interpret cooperatively the damage information in the internet environment, and further to estimate the spatial distribution of damage index or intensity, casualties or economic losses, which are very useful for the decision-making of emergency rescue and disaster relief, resettlement and reconstruction. The spatial seismic damage distribution of 2015 Ms 8.1 Nepal earthquake, as an example of the above solution, is evaluated by using the high resolution digital RS images, auxiliary geographic information and ground survey. The results are compared with the statistical disaster information issued by the ground truth by field surveying, and show good consistency.
ERIC Educational Resources Information Center
Westbrook, R. Niccole; Watkins, Sean
2012-01-01
As primary source materials in the library are digitized and made available online, the focus of related library services is shifting to include new and innovative methods of digital delivery via social media, digital storytelling, and community-based and consortial image repositories. Most images on the Web are not of sufficient quality for most…
Kreutz, Jason E; Munson, Todd; Huynh, Toan; Shen, Feng; Du, Wenbin; Ismagilov, Rustem F
2011-11-01
This paper presents a protocol using theoretical methods and free software to design and analyze multivolume digital PCR (MV digital PCR) devices; the theory and software are also applicable to design and analysis of dilution series in digital PCR. MV digital PCR minimizes the total number of wells required for "digital" (single molecule) measurements while maintaining high dynamic range and high resolution. In some examples, multivolume designs with fewer than 200 total wells are predicted to provide dynamic range with 5-fold resolution similar to that of single-volume designs requiring 12,000 wells. Mathematical techniques were utilized and expanded to maximize the information obtained from each experiment and to quantify performance of devices and were experimentally validated using the SlipChip platform. MV digital PCR was demonstrated to perform reliably, and results from wells of different volumes agreed with one another. No artifacts due to different surface-to-volume ratios were observed, and single molecule amplification in volumes ranging from 1 to 125 nL was self-consistent. The device presented here was designed to meet the testing requirements for measuring clinically relevant levels of HIV viral load at the point-of-care (in plasma, <500 molecules/mL to >1,000,000 molecules/mL), and the predicted resolution and dynamic range was experimentally validated using a control sequence of DNA. This approach simplifies digital PCR experiments, saves space, and thus enables multiplexing using separate areas for each sample on one chip, and facilitates the development of new high-performance diagnostic tools for resource-limited applications. The theory and software presented here are general and are applicable to designing and analyzing other digital analytical platforms including digital immunoassays and digital bacterial analysis. It is not limited to SlipChip and could also be useful for the design of systems on platforms including valve-based and droplet-based platforms. In a separate publication by Shen et al. (J. Am. Chem. Soc., 2011, DOI: 10.1021/ja2060116), this approach is used to design and test digital RT-PCR devices for quantifying RNA.
Sheng, Duo; Lai, Hsiu-Fan; Chan, Sheng-Min; Hong, Min-Rong
2015-02-13
An all-digital on-chip delay sensor (OCDS) circuit with high delay-measurement resolution and low supply-voltage sensitivity for efficient detection and diagnosis in high-performance electronic system applications is presented. Based on the proposed delay measurement scheme, the quantization resolution of the proposed OCDS can be reduced to several picoseconds. Additionally, the proposed cascade-stage delay measurement circuit can enhance immunity to supply-voltage variations of the delay measurement resolution without extra self-biasing or calibration circuits. Simulation results show that the delay measurement resolution can be improved to 1.2 ps; the average delay resolution variation is 0.55% with supply-voltage variations of ±10%. Moreover, the proposed delay sensor can be implemented in an all-digital manner, making it very suitable for high-performance electronic system applications as well as system-level integration.
High-resolution terahertz inline digital holography based on quantum cascade laser
NASA Astrophysics Data System (ADS)
Deng, Qinghua; Li, Weihua; Wang, Xuemin; Li, Zeyu; Huang, Haochong; Shen, Changle; Zhan, Zhiqiang; Zou, Ruijiao; Jiang, Tao; Wu, Weidong
2017-11-01
A key requirement to put terahertz (THz) imaging systems into applications is high resolution. Based on a self-developed THz quantum cascade laser (QCL), we demonstrate a THz inline digital holography imaging system with high lateral resolution. In our case, the lateral resolution of this holography imaging system is pushed to about 70 μm, which is close to the intrinsic resolution limit of this system. To the best of our knowledge, this is much smaller than what has been reported up to now. This is attributed to a series of improvements, such as shortening the QCL wavelength, increasing Nx and Ny by the synthetic aperture method, smoothing the source beam profile, and diminishing vibration due to the cryorefrigeration device. This kind of holography system with a resolution smaller than 100 μm opens the door for many imaging experiments. It will turn the THz imaging systems into applications.
Wavelength scanning digital interference holography for high-resolution ophthalmic imaging
NASA Astrophysics Data System (ADS)
Potcoava, Mariana C.; Kim, M. K.; Kay, Christine N.
2009-02-01
An improved digital interference holography (DIH) technique suitable for fundus images is proposed. This technique incorporates a dispersion compensation algorithm to compensate for the unknown axial length of the eye. Using this instrument we acquired successfully tomographic fundus images in human eye with narrow axial resolution less than 5μm. The optic nerve head together with the surrounding retinal vasculature were constructed. We were able to quantify a depth of 84μm between the retinal fiber and the retinal pigmented epithelium layers. DIH provides high resolution 3D information which could potentially aid in guiding glaucoma diagnosis and treatment.
Hierarchical nucleus segmentation in digital pathology images
NASA Astrophysics Data System (ADS)
Gao, Yi; Ratner, Vadim; Zhu, Liangjia; Diprima, Tammy; Kurc, Tahsin; Tannenbaum, Allen; Saltz, Joel
2016-03-01
Extracting nuclei is one of the most actively studied topic in the digital pathology researches. Most of the studies directly search the nuclei (or seeds for the nuclei) from the finest resolution available. While the richest information has been utilized by such approaches, it is sometimes difficult to address the heterogeneity of nuclei in different tissues. In this work, we propose a hierarchical approach which starts from the lower resolution level and adaptively adjusts the parameters while progressing into finer and finer resolution. The algorithm is tested on brain and lung cancers images from The Cancer Genome Atlas data set.
NASA Astrophysics Data System (ADS)
Aspinall, M. D.; Joyce, M. J.; Mackin, R. O.; Jarrah, Z.; Boston, A. J.; Nolan, P. J.; Peyton, A. J.; Hawkes, N. P.
2009-01-01
A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s-1. Events arising from the 7Li(p, n)7Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential.
42 CFR 37.42 - Chest radiograph specifications-digital radiography systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... resolution, modulation transfer function (MTF), image signal-to-noise and detective quantum efficiency must... Information Object Definitions, sections: Computed Radiography Image Information Object Definition; Digital X...
NASA Astrophysics Data System (ADS)
Pandiyan, Vimal Prabhu; Khare, Kedar; John, Renu
2017-09-01
A constrained optimization approach with faster convergence is proposed to recover the complex object field from a near on-axis digital holography (DH). We subtract the DC from the hologram after recording the object beam and reference beam intensities separately. The DC-subtracted hologram is used to recover the complex object information using a constrained optimization approach with faster convergence. The recovered complex object field is back propagated to the image plane using the Fresnel back-propagation method. The results reported in this approach provide high-resolution images compared with the conventional Fourier filtering approach and is 25% faster than the previously reported constrained optimization approach due to the subtraction of two DC terms in the cost function. We report this approach in DH and digital holographic microscopy using the U.S. Air Force resolution target as the object to retrieve the high-resolution image without DC and twin image interference. We also demonstrate the high potential of this technique in transparent microelectrode patterned on indium tin oxide-coated glass, by reconstructing a high-resolution quantitative phase microscope image. We also demonstrate this technique by imaging yeast cells.
Super-resolved Mirau digital holography by structured illumination
NASA Astrophysics Data System (ADS)
Ganjkhani, Yasaman; Charsooghi, Mohammad A.; Akhlaghi, Ehsan A.; Moradi, Ali-Reza
2017-12-01
In this paper, we apply structured illumination toward super-resolved 3D imaging in a common-path digital holography arrangement. Digital holographic microscopy (DHM) provides non-invasive 3D images of transparent samples as well as 3D profiles of reflective surfaces. A compact and vibration-immune arrangement for DHM may be obtained through the use of a Mirau microscope objective. However, high-magnification Mirau objectives have a low working distance and are expensive. Low-magnification ones, on the other hand, suffer from low lateral resolution. Structured illumination has been widely used for resolution improvement of intensity images, but the technique can also be readily applied to DHM. We apply structured illumination to Mirau DHM by implementing successive sinusoidal gratings with different orientations onto a spatial light modulator (SLM) and forming its image on the specimen. Moreover, we show that, instead of different orientations of 1D gratings, alternative single 2D gratings, e.g. checkerboard or hexagonal patterns, can provide resolution enhancement in multiple directions. Our results show a 35% improvement in the resolution power of the DHM. The presented arrangement has the potential to serve as a table-top device for high resolution holographic microscopy.
A review on high-resolution CMOS delay lines: towards sub-picosecond jitter performance.
Abdulrazzaq, Bilal I; Abdul Halin, Izhal; Kawahito, Shoji; Sidek, Roslina M; Shafie, Suhaidi; Yunus, Nurul Amziah Md
2016-01-01
A review on CMOS delay lines with a focus on the most frequently used techniques for high-resolution delay step is presented. The primary types, specifications, delay circuits, and operating principles are presented. The delay circuits reported in this paper are used for delaying digital inputs and clock signals. The most common analog and digitally-controlled delay elements topologies are presented, focusing on the main delay-tuning strategies. IC variables, namely, process, supply voltage, temperature, and noise sources that affect delay resolution through timing jitter are discussed. The design specifications of these delay elements are also discussed and compared for the common delay line circuits. As a result, the main findings of this paper are highlighting and discussing the followings: the most efficient high-resolution delay line techniques, the trade-off challenge found between CMOS delay lines designed using either analog or digitally-controlled delay elements, the trade-off challenge between delay resolution and delay range and the proposed solutions for this challenge, and how CMOS technology scaling can affect the performance of CMOS delay lines. Moreover, the current trends and efforts used in order to generate output delayed signal with low jitter in the sub-picosecond range are presented.
ERIC Educational Resources Information Center
Banks, Alton J.; Holmes, Jon L.
1995-01-01
Describes the characteristics of the digitized version of The Periodic Table Videodisc. Provides details about the organization of information and access to the data via Macintosh and Windows computers. (DDR)
Sarnoff JND Vision Model for Flat-Panel Design
NASA Technical Reports Server (NTRS)
Brill, Michael H.; Lubin, Jeffrey
1998-01-01
This document describes adaptation of the basic Sarnoff JND Vision Model created in response to the NASA/ARPA need for a general-purpose model to predict the perceived image quality attained by flat-panel displays. The JND model predicts the perceptual ratings that humans will assign to a degraded color-image sequence relative to its nondegraded counterpart. Substantial flexibility is incorporated into this version of the model so it may be used to model displays at the sub-pixel and sub-frame level. To model a display (e.g., an LCD), the input-image data can be sampled at many times the pixel resolution and at many times the digital frame rate. The first stage of the model downsamples each sequence in time and in space to physiologically reasonable rates, but with minimum interpolative artifacts and aliasing. Luma and chroma parts of the model generate (through multi-resolution pyramid representation) a map of differences-between test and reference called the JND map, from which a summary rating predictor is derived. The latest model extensions have done well in calibration against psychophysical data and against image-rating data given a CRT-based front-end. THe software was delivered to NASA Ames and is being integrated with LCD display models at that facility,
Enhancement of digital radiography image quality using a convolutional neural network.
Sun, Yuewen; Li, Litao; Cong, Peng; Wang, Zhentao; Guo, Xiaojing
2017-01-01
Digital radiography system is widely used for noninvasive security check and medical imaging examination. However, the system has a limitation of lower image quality in spatial resolution and signal to noise ratio. In this study, we explored whether the image quality acquired by the digital radiography system can be improved with a modified convolutional neural network to generate high-resolution images with reduced noise from the original low-quality images. The experiment evaluated on a test dataset, which contains 5 X-ray images, showed that the proposed method outperformed the traditional methods (i.e., bicubic interpolation and 3D block-matching approach) as measured by peak signal to noise ratio (PSNR) about 1.3 dB while kept highly efficient processing time within one second. Experimental results demonstrated that a residual to residual (RTR) convolutional neural network remarkably improved the image quality of object structural details by increasing the image resolution and reducing image noise. Thus, this study indicated that applying this RTR convolutional neural network system was useful to improve image quality acquired by the digital radiography system.
Fast front-end electronics for semiconductor tracking detectors: Trends and perspectives
NASA Astrophysics Data System (ADS)
Rivetti, Angelo
2014-11-01
In the past few years, extensive research efforts pursued by both the industry and the academia have lead to major improvements in the performance of Analog to Digital Converters (ADCs) and Time to Digital Converters (TDCs). ADCs achieving 8-10 bit resolution, 50-100 MHz conversion frequency and less than 1 mW power consumption are the today's standard, while TDCs have reached sub-picosecond time resolution. These results have been made possible by architectural upgrades combined with the use of ultra deep submicron CMOS technologies with minimum feature size of 130 nm or smaller. Front-end ASICs in which a prompt digitization is followed by signal conditioning in the digital domain can now be envisaged also within the tight power budget typically available in high density tracking systems. Furthermore, tracking detectors embedding high resolution timing capabilities are gaining interest. In the paper, ADC's and TDC's developments which are of particular relevance for the design front-end electronics for semiconductor trackers are discussed along with the benefits and challenges of exploiting such high performance building blocks in implementing the next generation of ASICs for high granularity particle detectors.
Fast Low-Cost Multiple Sensor Readout System
Carter-Lewis, David; Krennich, Frank; Le Bohec, Stephane; Petry, Dirk; Sleege, Gary
2004-04-06
A low resolution data acquisition system is presented. The data acquisition system has a plurality of readout modules serially connected to a controller. Each readout module has a FPGA in communication with analog to digital (A/D) converters, which are connected to sensors. The A/D converter has eight bit or lower resolution. The FPGA detects when a command is addressed to it and commands the A/D converters to convert analog sensor data into digital data. The digital data is sent on a high speed serial communication bus to the controller. A graphical display is used in one embodiment to indicate if a sensor reading is outside of a predetermined range.
[INVITED] Laser-induced forward transfer: A high resolution additive manufacturing technology
NASA Astrophysics Data System (ADS)
Delaporte, Philippe; Alloncle, Anne-Patricia
2016-04-01
Among the additive manufacturing techniques, laser-induced forward transfer addresses the challenges of printing thin films in solid phase or small volume droplets in liquid phase with very high resolution. This paper reviews the physics of this process and explores the pros and cons of this technology versus other digital printing technologies. The main field of applications are printed electronics, organic electronics and tissue engineering, and the most promising short terms ones concern digital laser printing of sensors and conductive tracks. Future directions and emerging areas of interest are discussed such as printing solid from a liquid phase and 3D digital nanomanufacturing.
Rowlands, J A; Hunter, D M; Araj, N
1991-01-01
A new digital image readout method for electrostatic charge images on photoconductive plates is described. The method can be used to read out images on selenium plates similar to those used in xeromammography. The readout method, called the air-gap photoinduced discharge method (PID), discharges the latent image pixel by pixel and measures the charge. The PID readout method, like electrometer methods, is linear. However, the PID method permits much better resolution than scanning electrometers while maintaining quantum limited performance at high radiation exposure levels. Thus the air-gap PID method appears to be uniquely superior for high-resolution digital imaging tasks such as mammography.
Unmanned Aircraft Systems Roadmap, 2005-2030
2005-01-01
directly addresses the dangerous mission of attacking or degrading integrated air defense systems. The attributes that make the use of unmanned...meter of reinforced concrete covered by one meter of soil . The Air Force hopes to deploy it by 2007 on the F-15E, followed by deployment on several... degradation from repeated analog-digital-analog conversions. For this reason, multispectral versions of digital focal arrays are critical. Additionally
Validation Test Report for GDEM4
2010-08-19
standard deviations called the Generalized Digital Environmental Model ( GDEM ). The present document describes the development and evaluation of GDEM4...the newest version of GDEM . As part of the evaluation of GDEM4, comparisons are made in this report to GDEM3 and to four other ocean climatologies...depth climatology of temperature and salinity and their standard deviations called the Generalized Digital Environmental Model ( GDEM ). The history of
,
2006-01-01
he growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO export files and as ArcView shape files. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
,
2006-01-01
The growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO Exportfiles/ and as ArcView shape files. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
Digital data for the geology of the Southern Brooks Range, Alaska
Till, Alison B.; Dumoulin, Julie A.; Harris, Anita G.; Moore, Thomas E.; Bleick, Heather A.; Siwiec, Benjamin; Labay, Keith A.; Wilson, Frederic H.; Shew, Nora B.
2008-01-01
The growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO export files and as ArcView shape files. The files named __geol contain geologic polygons and line (contact) attributes; files named __fold contain fold axes; files named __lin contain lineaments; and files named __dike contain dikes as lines. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
Wilson, Frederic H.; Hults, Chad P.; Labay, Keith A.; Shew, Nora B.
2007-01-01
The growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO export files and as ArcView shape files. The files named __geol contain geologic polygons and line (contact) attributes; files named __fold contain fold axes; files named __lin contain lineaments; and files named __dike contain dikes as lines. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
Till, Alison B.; Dumoulin, Julie A.; Phillips, Jeffrey D.; Stanley, Richard G.; Crews, Jessie
2006-01-01
The growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO export files and as ArcView shape files. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
,
2006-01-01
The growth in the use of Geographic Information Systems (GIS) has highlighted the need for digital geologic maps that have been attributed with information about age and lithology. Such maps can be conveniently used to generate derivative maps for manifold special purposes such as mineral-resource assessment, metallogenic studies, tectonic studies, and environmental research. This report is part of a series of integrated geologic map databases that cover the entire United States. Three national-scale geologic maps that portray most or all of the United States already exist; for the conterminous U.S., King and Beikman (1974a,b) compiled a map at a scale of 1:2,500,000, Beikman (1980) compiled a map for Alaska at 1:2,500,000 scale, and for the entire U.S., Reed and others (2005a,b) compiled a map at a scale of 1:5,000,000. A digital version of the King and Beikman map was published by Schruben and others (1994). Reed and Bush (2004) produced a digital version of the Reed and others (2005a) map for the conterminous U.S. The present series of maps is intended to provide the next step in increased detail. State geologic maps that range in scale from 1:100,000 to 1:1,000,000 are available for most of the country, and digital versions of these state maps are the basis of this product. The digital geologic maps presented here are in a standardized format as ARC/INFO export files and as ArcView shape files. Data tables that relate the map units to detailed lithologic and age information accompany these GIS files. The map is delivered as a set 1:250,000-scale quadrangle files. To the best of our ability, these quadrangle files are edge-matched with respect to geology. When the maps are merged, the combined attribute tables can be used directly with the merged maps to make derivative maps.
NASA Astrophysics Data System (ADS)
Olokeogun, O. S.; Akintola, O. O.; Abodunrin, E. K.
2016-06-01
This study demonstrates the potentials of Geographic Information System (GIS) as a management tool for avenue trees (Street trees) populations in small communities (using Idi-Ishin community, Ibadan, Nigeria as a case study). GIS is a decision support system which integrate data or set of data from different sources, bringing them under the same referencing system in a computer system. An Ikonos Imagery (1m Spatial Resolution) of the study area was digitized to produce a digital map using ArcGIS 10.1 version. The avenue trees species ≥ 5cm diameter at breast height (DBH) was selected for enumeration. These trees were then measured and tagged. The Height, Girth and Geographic location (X &Y coordinate) of the trees were measured with Haga altimeter, Girthing tape and Hand held Global Positioning System (GPS) respectively. The species and families of the trees enumerated were also identified. Data were analysed for basal area (BA) and volume (V). A total number of 43 avenue trees were assessed in Idi-Ishin Community. Roystonea regia accounted for the majority of the avenue trees (25.58%), followed by Polyanthia longiflora (23.26%), Gliricida seprium (20.93%), Eucalyptus toreliana (13.95%), Delunix regea (6.98%). However Terminalia catapa, Terminalia radii, Azadrachita indica and Newbodia levis had the same abundance of 2.33%. It was also observed that the benefits derived from these avenue trees includes; Carbon sequestration, Beautification, Wind break and shade. A spatial relational database was created for the assessed avenue trees using ArcCatalog of ArcGIS 10.1 version. Based on the findings from the study (which serves as baseline information for the management of the avenue trees in the study area), it was therefore recommended that subsequent assessment should be carried out at 3-5 year interval in other to ensure proper and continuous monitoring and updating of the data.
Influence of imaging resolution on color fidelity in digital archiving.
Zhang, Pengchang; Toque, Jay Arre; Ide-Ektessabi, Ari
2015-11-01
Color fidelity is of paramount importance in digital archiving. In this paper, the relationship between color fidelity and imaging resolution was explored by calculating the color difference of an IT8.7/2 color chart with a CIELAB color difference formula for scanning and simulation images. Microscopic spatial sampling was used in selecting the image pixels for the calculations to highlight the loss of color information. A ratio, called the relative imaging definition (RID), was defined to express the correlation between image resolution and color fidelity. The results show that in order for color differences to remain unrecognizable, the imaging resolution should be at least 10 times higher than the physical dimension of the smallest feature in the object being studied.
A Capacitance-To-Digital Converter for MEMS Sensors for Smart Applications.
Pérez Sanjurjo, Javier; Prefasi, Enrique; Buffa, Cesare; Gaggl, Richard
2017-06-07
The use of MEMS sensors has been increasing in recent years. To cover all the applications, many different readout circuits are needed. To reduce the cost and time to market, a generic capacitance-to-digital converter (CDC) seems to be the logical next step. This work presents a configurable CDC designed for capacitive MEMS sensors. The sensor is built with a bridge of MEMS, where some of them function with pressure. Then, the capacitive to digital conversion is realized using two steps. First, a switched-capacitor (SC) preamplifier is used to make the capacitive to voltage (C-V) conversion. Second, a self-oscillated noise-shaping integrating dual-slope (DS) converter is used to digitize this magnitude. The proposed converter uses time instead of amplitude resolution to generate a multibit digital output stream. In addition it performs noise shaping of the quantization error to reduce measurement time. This article shows the effectiveness of this method by measurements performed on a prototype, designed and fabricated using standard 0.13 µm CMOS technology. Experimental measurements show that the CDC achieves a resolution of 17 bits, with an effective area of 0.317 mm², which means a pressure resolution of 1 Pa, while consuming 146 µA from a 1.5 V power supply.
A Capacitance-To-Digital Converter for MEMS Sensors for Smart Applications
Pérez Sanjurjo, Javier; Prefasi, Enrique; Buffa, Cesare; Gaggl, Richard
2017-01-01
The use of MEMS sensors has been increasing in recent years. To cover all the applications, many different readout circuits are needed. To reduce the cost and time to market, a generic capacitance-to-digital converter (CDC) seems to be the logical next step. This work presents a configurable CDC designed for capacitive MEMS sensors. The sensor is built with a bridge of MEMS, where some of them function with pressure. Then, the capacitive to digital conversion is realized using two steps. First, a switched-capacitor (SC) preamplifier is used to make the capacitive to voltage (C-V) conversion. Second, a self-oscillated noise-shaping integrating dual-slope (DS) converter is used to digitize this magnitude. The proposed converter uses time instead of amplitude resolution to generate a multibit digital output stream. In addition it performs noise shaping of the quantization error to reduce measurement time. This article shows the effectiveness of this method by measurements performed on a prototype, designed and fabricated using standard 0.13 µm CMOS technology. Experimental measurements show that the CDC achieves a resolution of 17 bits, with an effective area of 0.317 mm2, which means a pressure resolution of 1 Pa, while consuming 146 µA from a 1.5 V power supply. PMID:28590425
THz holography in reflection using a high resolution microbolometer array.
Zolliker, Peter; Hack, Erwin
2015-05-04
We demonstrate a digital holographic setup for Terahertz imaging of surfaces in reflection. The set-up is based on a high-power continuous wave (CW) THz laser and a high-resolution (640 × 480 pixel) bolometer detector array. Wave propagation to non-parallel planes is used to reconstruct the object surface that is rotated relative to the detector plane. In addition we implement synthetic aperture methods for resolution enhancement and compare Fourier transform phase retrieval to phase stepping methods. A lateral resolution of 200 μm and a relative phase sensitivity of about 0.4 rad corresponding to a depth resolution of 6 μm are estimated from reconstructed images of two specially prepared test targets, respectively. We highlight the use of digital THz holography for surface profilometry as well as its potential for video-rate imaging.
Measurement of the energy and time resolution of a undoped CsI + MPPC array for the Mu2e experiment
Atanova, O.; Cordelli, M.; Corradi, G.; ...
2017-02-13
This paper describes the measurements of energy and time response and resolution of a 3 x 3 array made of undoped CsI crystals coupled to large area Hamamatsu Multi Pixel Photon Counters. The measurements have been performed using the electron beam of the Beam Test Facility in Frascati (Rome, Italy) in the energy range 80-120 MeV. The measured energy resolution, estimated with the FWHM, at 100 MeV is 16.4%. This resolution is dominated by the energy leakage due to the small dimensions of the prototype. The time is reconstructed by fitting the leading edge of the digitized signals and applyingmore » a digital constant fraction discrimination technique. A time resolution of about 110 ps at 100 MeV is achieved.« less
Super-resolved microsphere-assisted Mirau digital holography by oblique illumination
NASA Astrophysics Data System (ADS)
Abbasian, Vahid; Ganjkhani, Yasaman; Akhlaghi, Ehsan A.; Anand, Arun; Javidi, Bahram; Moradi, Ali-Reza
2018-06-01
In this paper, oblique illumination is used to improve the lateral resolution and edge sharpness in microsphere (MS)-assisted Mirau digital holographic microscopy (Mirau-DHM). Abbe showed that tilting the illumination light allows entrance of higher spatial frequencies into the imaging system thus increasing the resolution power. We extended the idea to common-path DHM, based on Mirau objective, toward super-resolved 3D imaging. High magnification Mirau objectives are very expensive and low-magnification ones suffer from low resolution, therefore, any attempt to increase the effective resolution of the system may be of a great interest. We have already demonstrated the effective resolution increasing of a Mirau-DHM system by incorporating a transparent MS within the working distance of the objective. Here, we show that by integrating a MS-assisted Mirau-DHM with the oblique illumination even higher resolutions can be achieved. We have applied the technique for various samples and have shown the increase in the lateral resolution for the both cases of Mirau-DHM with and without the MS.
A Low-Power All-Digital on-Chip CMOS Oscillator for a Wireless Sensor Node
Sheng, Duo; Hong, Min-Rong
2016-01-01
This paper presents an all-digital low-power oscillator for reference clocks in wireless body area network (WBAN) applications. The proposed on-chip complementary metal-oxide-semiconductor (CMOS) oscillator provides low-frequency clock signals with low power consumption, high delay resolution, and low circuit complexity. The cascade-stage structure of the proposed design simultaneously achieves high resolution and a wide frequency range. The proposed hysteresis delay cell further reduces the power consumption and hardware costs by 92.4% and 70.4%, respectively, relative to conventional designs. The proposed design is implemented in a standard performance 0.18 μm CMOS process. The measured operational frequency ranged from 7 to 155 MHz, and the power consumption was improved to 79.6 μW (@7 MHz) with a 4.6 ps resolution. The proposed design can be implemented in an all-digital manner, which is highly desirable for system-level integration. PMID:27754439
NASA Astrophysics Data System (ADS)
Singh, Mandeep; Khare, Kedar
2018-05-01
We describe a numerical processing technique that allows single-shot region-of-interest (ROI) reconstruction in image plane digital holographic microscopy with full pixel resolution. The ROI reconstruction is modelled as an optimization problem where the cost function to be minimized consists of an L2-norm squared data fitting term and a modified Huber penalty term that are minimized alternately in an adaptive fashion. The technique can provide full pixel resolution complex-valued images of the selected ROI which is not possible to achieve with the commonly used Fourier transform method. The technique can facilitate holographic reconstruction of individual cells of interest from a large field-of-view digital holographic microscopy data. The complementary phase information in addition to the usual absorption information already available in the form of bright field microscopy can make the methodology attractive to the biomedical user community.
A Low-Power All-Digital on-Chip CMOS Oscillator for a Wireless Sensor Node.
Sheng, Duo; Hong, Min-Rong
2016-10-14
This paper presents an all-digital low-power oscillator for reference clocks in wireless body area network (WBAN) applications. The proposed on-chip complementary metal-oxide-semiconductor (CMOS) oscillator provides low-frequency clock signals with low power consumption, high delay resolution, and low circuit complexity. The cascade-stage structure of the proposed design simultaneously achieves high resolution and a wide frequency range. The proposed hysteresis delay cell further reduces the power consumption and hardware costs by 92.4% and 70.4%, respectively, relative to conventional designs. The proposed design is implemented in a standard performance 0.18 μm CMOS process. The measured operational frequency ranged from 7 to 155 MHz, and the power consumption was improved to 79.6 μW (@7 MHz) with a 4.6 ps resolution. The proposed design can be implemented in an all-digital manner, which is highly desirable for system-level integration.
Optical digital microscopy for cyto- and hematological studies in vitro
NASA Astrophysics Data System (ADS)
Ganilova, Yu. A.; Dolmashkin, A. A.; Doubrovski, V. A.; Yanina, I. Yu.; Tuchin, V. V.
2013-08-01
The dependence of the spatial resolution and field of view of an optical microscope equipped with a CCD camera on the objective magnification has been experimentally investigated. Measurement of these characteristics has shown that a spatial resolution of 20-25 px/μm at a field of view of about 110 μm is quite realistic; this resolution is acceptable for a detailed study of the processes occurring in cell. It is proposed to expand the dynamic range of digital camera by measuring and approximating its light characteristics with subsequent plotting of the corresponding calibration curve. The biological objects of study were human adipose tissue cells, as well as erythrocytes and their immune complexes in human blood; both objects have been investigated in vitro. Application of optical digital microscopy for solving specific problems of cytology and hematology can be useful in both biomedical studies in experiments with objects of nonbiological origin.
Study of fish response using particle image velocimetry and high-speed, high-resolution imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Z.; Richmond, M. C.; Mueller, R. P.
2004-10-01
Fish swimming has fascinated both engineers and fish biologists for decades. Digital particle image velocimetry (DPIV) and high-speed, high-resolution digital imaging are recently developed analysis tools that can help engineers and biologists better understand how fish respond to turbulent environments. This report details studies to evaluate DPIV. The studies included a review of existing literature on DPIV, preliminary studies to test the feasibility of using DPIV conducted at our Flow Biology Laboratory in Richland, Washington September through December 2003, and applications of high-speed, high-resolution digital imaging with advanced motion analysis to investigations of fish injury mechanisms in turbulent shear flowsmore » and bead trajectories in laboratory physical models. Several conclusions were drawn based on these studies, which are summarized as recommendations for proposed research at the end of this report.« less
NASA Astrophysics Data System (ADS)
Yin, Yujian; Su, Ping; Ma, Jianshe
2018-01-01
A method to improve the radial resolution using special structured light is proposed in the field of digital holographic microscopy (DHM). A specimen is illuminated with circular symmetrical structured light that makes the spectrum have radial movement, so that high frequency components of the specimen are moved into the passband of the receiver to overcome the diffraction limit. In the DHM imaging system, Computer Generated Hologram (CGH) technology is used to generate the required structured light grating. Then the grating is loaded into a spatial light modulator (SLM) to obtain specific structured illumination. After recording the hologram, digital reconstruction, for the microstructure of a binary optical element that needs to observe radial distribution, the radial resolution of the specimen is improved experimentally compare it with the result of one-dimensional sinusoidal structured light imaging. And a method of designing structured light is presented.
High resolution data acquisition
Thornton, G.W.; Fuller, K.R.
1993-04-06
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
High resolution data acquisition
Thornton, Glenn W.; Fuller, Kenneth R.
1993-01-01
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
NASA Astrophysics Data System (ADS)
Pickett, Brian K.; Cassen, Patrick; Durisen, Richard H.; Link, Robert
2000-02-01
In the paper ``The Effects of Thermal Energetics on Three-dimensional Hydrodynamic Instabilities in Massive Protostellar Disks. II. High-Resolution and Adiabatic Evolutions'' by Brian K. Pickett, Patrick Cassen, Richard H. Durisen, and Robert Link (ApJ, 529, 1034 [2000]), the wrong version of Figure 10 was published as a result of an error at the Press. The correct version of Figure 10 appears below. The Press sincerely regrets this error.
Buttenfield, B.P.; Stanislawski, L.V.; Brewer, C.A.
2011-01-01
This paper reports on generalization and data modeling to create reduced scale versions of the National Hydrographic Dataset (NHD) for dissemination through The National Map, the primary data delivery portal for USGS. Our approach distinguishes local differences in physiographic factors, to demonstrate that knowledge about varying terrain (mountainous, hilly or flat) and varying climate (dry or humid) can support decisions about algorithms, parameters, and processing sequences to create generalized, smaller scale data versions which preserve distinct hydrographic patterns in these regions. We work with multiple subbasins of the NHD that provide a range of terrain and climate characteristics. Specifically tailored generalization sequences are used to create simplified versions of the high resolution data, which was compiled for 1:24,000 scale mapping. Results are evaluated cartographically and metrically against a medium resolution benchmark version compiled for 1:100,000, developing coefficients of linear and areal correspondence.
NASA Astrophysics Data System (ADS)
Streicher, Michael W.
A nuclear weapon detonation remains one of the gravest threats to the global community. Although the likelihood of a nuclear event remains small, the economic and political ramifications of an event are vast. The surest way to reduce the probability of an incident is to account for the special nuclear materials (SNM) which can be used to produce a nuclear weapon. Materials which can be used to manufacture a radiological dispersion device ("dirty bomb") must also be monitored. Rapidly-deployable, commercially-available, room-temperature imaging gamma-ray spectrometers are improving the ability of authorities to intelligently and quickly respond to threats. New electronics which digitally-sample the radiation-induced signals in CdZnTe detectors have expanded the capabilities of these sensors. This thesis explores national security applications where digital readout of CdZnTe detectors significantly enhances capabilities. Radioactive sources can be detected more quickly using digitally-sampled CdZnTe detector due to the improved energy resolution. The excellent energy resolution also improves the accuracy of measurements of uranium enrichment and allows users to measure plutonium grade. Small differences in the recorded gamma-ray energy spectrum can be used to estimate the effective atomic number and mass thickness of materials shielding SNM sources. Improved position resolution of gamma-ray interactions through digital readout allows high resolution gamma-ray images of SNM revealing information about the source configuration. CdZnTe sensors can detect the presence of neutrons, indirectly, through measurement of gamma rays released during capture of thermal neutrons by Cd-113 or inelastic scattering with any constituent nuclei. Fast neutrons, such as those released following fission, can be directly detected through elastic scattering interactions in the detector. Neutrons are a strong indicator of fissile material, and the background neutron rate is much lower than the gamma-ray background rate. Neutrons can more easily penetrate shielding materials as well which can greatly aid in the detection of shielded SNM. Digital CdZnTe readout enables the sensors to maintain excellent energy resolution at high count rates. Pulse pile-up and preamplifier decay can be monitored and corrected for on an event-by-event basis limiting energy resolution degradation in dose rates higher than 100 mR/hr. Finally, new iterations of the digital electronics have enhanced gamma-ray detection capabilities at high photon energies. Currently, gamma rays with energy up to 4.4 MeV have been detected. High-energy photon detection is critical for many proposed active interrogation systems.
Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C
2013-06-01
Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.
SRTM 3" comparison with local information: Two examples at national level in Peru
NASA Astrophysics Data System (ADS)
Plasencia Sánchez, Edson; Fernandez de Villarán, Ruben
2012-06-01
The access to the high resolution digital terrain models (DEM) generated from the data collected by the Shuttle Radar Topography Mission (SRTM) of NASA is freely available to the public. Consequently it has become a source of topographic information which is of great value to scientists involved in geophysical or geodetic analysis. Despite the efforts of the Consultative Group on International Agricultural Research (CGIAR), to validate and complement the information contained in these DEMs (currently offered as version 4.1), they still need to be checked for their accuracy in certain regions of the planet. In this paper, the vertical accuracy of the SRTM 3" version 4.1 DEM was analyzed in several areas of Peru using two sets of control points: the height of the district capitals (the minor politics units) and the heights of the weather and hydrological stations from the National Meteorology and Hydrology Service (SENAMHI) of Peru. The comparison shows that the height differences are independent of the altitude, latitude and longitude of the evaluated points. They are rather related to the aspect of the terrain and to the way the SRTM data were acquired. It shows that the mean square of the height differences at national level was ±20 m for district capitals and ±25 m for the SENAMHI stations. This is slightly larger than the overall accuracy of the SRTM ±16 m.
Ryder, Robert T.; Harris, Anita G.; Repetski, John E.; Crangle, Robert D.; Ruppert, Leslie F.; Ryder, Robert T.
2014-01-01
This chapter is a re-release of U.S. Geological Survey Bulletin 1839-K, of the same title, by Ryder and others (1992; online version 2.0 revised and digitized by Robert D. Crangle, Jr., 2003). It consists of one file of the report text as it appeared in USGS Bulletin 1839-K and a second file containing the cross section, figures 1 and 2, and tables 1 and 2 on one oversized sheet; the second file was digitized in 2003 as version 2.0 and also includes the gamma-ray well log traces.
Polarized light imaging of birefringence and diattenuation at high resolution and high sensitivity
Mehta, Shalin B.; Shribak, Michael; Oldenbourg, Rudolf
2013-01-01
Polarized light microscopy provides unique opportunities for analyzing the molecular order in man-made and natural materials, including biological structures inside living cells, tissues, and whole organisms. 20 years ago, the LC-PolScope was introduced as a modern version of the traditional polarizing microscope enhanced by liquid crystal devices for the control of polarization, and by electronic imaging and digital image processing for fast and comprehensive image acquisition and analysis. The LCPolScope is commonly used for birefringence imaging, analyzing the spatial and temporal variations of the differential phase delay in ordered and transparent materials. Here we describe an alternative use of the LC-PolScope for imaging the polarization dependent transmittance of dichroic materials. We explain the minor changes needed to convert the instrument between the two imaging modes, discuss the relationship between the quantities measured with either instrument, and touch on the physical connection between refractive index, birefringence, transmittance, diattenuation, and dichroism. PMID:24273640
Compact time- and space-integrating SAR processor: performance analysis
NASA Astrophysics Data System (ADS)
Haney, Michael W.; Levy, James J.; Michael, Robert R., Jr.; Christensen, Marc P.
1995-06-01
Progress made during the previous 12 months toward the fabrication and test of a flight demonstration prototype of the acousto-optic time- and space-integrating real-time SAR image formation processor is reported. Compact, rugged, and low-power analog optical signal processing techniques are used for the most computationally taxing portions of the SAR imaging problem to overcome the size and power consumption limitations of electronic approaches. Flexibility and performance are maintained by the use of digital electronics for the critical low-complexity filter generation and output image processing functions. The results reported for this year include tests of a laboratory version of the RAPID SAR concept on phase history data generated from real SAR high-resolution imagery; a description of the new compact 2D acousto-optic scanner that has a 2D space bandwidth product approaching 106 sports, specified and procured for NEOS Technologies during the last year; and a design and layout of the optical module portion of the flight-worthy prototype.
Benedict, Ralph H B; Smerbeck, Audrey; Parikh, Rajavi; Rodgers, Jonathan; Cadavid, Diego; Erlanger, David
2012-09-01
Cognitive impairment is common in multiple sclerosis (MS), but is seldom assessed in clinical trials investigating the effects of disease-modifying therapies. The Symbol Digit Modalities Test (SDMT) is a particularly promising tool due to its sensitivity and robust correlation with brain magnetic resonance imaging (MRI) and vocational disability. Unfortunately, there are no validated alternate SDMT forms, which are needed to mitigate practice effects. The aim of the study was to assess the reliability and equivalence of SDMT alternate forms. Twenty-five healthy participants completed each of five alternate versions of the SDMT - the standard form, two versions from the Rao Brief Repeatable Battery, and two forms specifically designed for this study. Order effects were controlled using a Latin-square research design. All five versions of the SDMT produced mean values within 3 raw score points of one another. Three forms were very consistent, and not different by conservative statistical tests. The SDMT test-retest reliability using these forms was good to excellent, with all r values exceeding 0.80. For the first time, we find good evidence that at least three alternate versions of the SDMT are of equivalent difficulty in healthy adults. The forms are reliable, and can be implemented in clinical trials emphasizing cognitive outcomes.
Fazel, Akbar; Aalai, Shima; Rismanchian, Mansour
2009-08-01
Macro-design influences the initial stability of implant and reduces micromotions. The aim of this study was to determine and compare micromotions and stress distribution in the bone around immediately loaded Maestro and Xive implants using finite element analysis. In this experimental study, accurate, clear photos were prepared of Xive and Maestro implants 12 and 13 mm long and 4 and 3.8 mm in diameter, respectively, using a Nikon Digital Camera with a resolution 5.24-megapixels with 8x Optical Zoom and 4x Digital Zoom. After accurate measurements, 3-D models of the implants inside the lower mandible (D2) were processed in Solidworks Version 2003 environment and transferred into Ansys for finite element analysis. After loading of 500 N angled at 70 degrees from the horizontal plane, the micromotion of the implant and Von Misses stresses around the bone were measured. The measured micromotion in Maestro implant was 148 mum and that in Xive was 284 mum. Stress distribution in the bone surrounding Maestro implant was better than Xive, but maximum stress surrounding Xive implants (30 MPa) was lower than Maestro (33 MPa). Based on the results obtained in the present study, maximum micromotion in maestro was less than that in Xive implants. This finding can guarantee the application of maestro implants for immediate loading.
The US Geological Survey, digital spectral reflectance library: version 1: 0.2 to 3.0 microns
NASA Technical Reports Server (NTRS)
Clark, Roger N.; Swayze, Gregg A.; King, Trude V. V.; Gallagher, Andrea J.; Calvin, Wendy M.
1993-01-01
We have developed a digital reflectance spectral library, with management and spectral analysis software. The library includes 500 spectra of 447 samples (some samples include a series of grain sizes) measured from approximately 0.2 to 3.0 microns. The spectral resolution (Full Width Half Maximum) of the reflectance data is less than or equal to 4 nm in the visible (0.2-0.8 microns) and less than or equal 10 nm in the NIR (0.8-2.35 microns). All spectra were corrected to absolute reflectance using an NBS Halon standard. Library management software lets users search on parameters (e.g. chemical formulae, chemical analyses, purity of samples, mineral groups, etc.) as well as spectral features. Minerals from sulfide, oxide, hydroxide, halide, carbonate, nitrate, borate, phosphate, and silicate groups are represented. X-ray and chemical analyses are tabulated for many of the entries, and all samples have been evaluated for spectral purity. The library also contains end and intermediate members for the olivine, garnet, scapolite, montmorillonite, muscovite, jarosite, and alunite solid-solution series. We have included representative spectra of H2O ice, kerogen, ammonium-bearing minerals, rare-earth oxides, desert varnish coatings, kaolinite crystallinity series, kaolinite-smectite series, zeolite series, and an extensive evaporite series. Because of the importance of vegetation to climate-change studies we have include 17 spectra of tree leaves, bushes, and grasses.
Tracking a Head-Mounted Display in a Room-Sized Environment with Head-Mounted Cameras
1990-04-01
poor resolution and a very limited working volume [Wan90]. 4 OPTOTRAK [Nor88] uses one camera with two dual-axis CCD infrared position sensors. Each...Nor88] Northern Digital. Trade literature on Optotrak - Northern Digital’s Three Dimensional Optical Motion Tracking and Analysis System. Northern Digital
Forest Stand Canopy Structure Attribute Estimation from High Resolution Digital Airborne Imagery
Demetrios Gatziolis
2006-01-01
A study of forest stand canopy variable assessment using digital, airborne, multispectral imagery is presented. Variable estimation involves stem density, canopy closure, and mean crown diameter, and it is based on quantification of spatial autocorrelation among pixel digital numbers (DN) using variogram analysis and an alternative, non-parametric approach known as...
Park, Jong Kang; Rowlands, Christopher J; So, Peter T C
2017-01-01
Temporal focusing multiphoton microscopy is a technique for performing highly parallelized multiphoton microscopy while still maintaining depth discrimination. While the conventional wide-field configuration for temporal focusing suffers from sub-optimal axial resolution, line scanning temporal focusing, implemented here using a digital micromirror device (DMD), can provide substantial improvement. The DMD-based line scanning temporal focusing technique dynamically trades off the degree of parallelization, and hence imaging speed, for axial resolution, allowing performance parameters to be adapted to the experimental requirements. We demonstrate this new instrument in calibration specimens and in biological specimens, including a mouse kidney slice.
Park, Jong Kang; Rowlands, Christopher J.; So, Peter T. C.
2017-01-01
Temporal focusing multiphoton microscopy is a technique for performing highly parallelized multiphoton microscopy while still maintaining depth discrimination. While the conventional wide-field configuration for temporal focusing suffers from sub-optimal axial resolution, line scanning temporal focusing, implemented here using a digital micromirror device (DMD), can provide substantial improvement. The DMD-based line scanning temporal focusing technique dynamically trades off the degree of parallelization, and hence imaging speed, for axial resolution, allowing performance parameters to be adapted to the experimental requirements. We demonstrate this new instrument in calibration specimens and in biological specimens, including a mouse kidney slice. PMID:29387484
A seamless, high-resolution digital elevation model (DEM) of the north-central California coast
Foxgrover, Amy C.; Barnard, Patrick L.
2012-01-01
A seamless, 2-meter resolution digital elevation model (DEM) of the north-central California coast has been created from the most recent high-resolution bathymetric and topographic datasets available. The DEM extends approximately 150 kilometers along the California coastline, from Half Moon Bay north to Bodega Head. Coverage extends inland to an elevation of +20 meters and offshore to at least the 3 nautical mile limit of state waters. This report describes the procedures of DEM construction, details the input data sources, and provides the DEM for download in both ESRI Arc ASCII and GeoTIFF file formats with accompanying metadata.
A Submillimeter Resolution PET Prototype Evaluated With an 18F Inkjet Printed Phantom
NASA Astrophysics Data System (ADS)
Schneider, Florian R.; Hohberg, Melanie; Mann, Alexander B.; Paul, Stephan; Ziegler, Sibylle I.
2015-10-01
This work presents a submillimeter resolution PET (Positron Emission Tomography) scanner prototype based on SiPM/MPPC arrays (Silicon Photomultiplier/Multi Pixel Photon Counter). Onto each active area a 1 ×1 ×20 mm3 LYSO (Lutetium-Yttrium-Oxyorthosilicate) scintillator crystal is coupled one-to-one. Two detector modules facing each other in a distance of 10.0 cm have been set up with in total 64 channels that are digitized by SADCs (Sampling Analog to Digital Converters) with 80 MHz, 10 bit resolution and FPGA (Field Programmable Gate Array) based extraction of energy and time information. Since standard phantoms are not sufficient for testing submillimeter resolution at which positron range is an issue, a 18F inkjet printed phantom has been used to explore the limit in spatial resolution. The phantom could be successfully reconstructed with an iterative MLEM (Maximum Likelihood Expectation Maximization) and an analytically calculated system matrix based on the DRF (Detector Response Function) model. The system yields a coincidence time resolution of 4.8 ns FWHM, an energy resolution of 20%-30% FWHM and a spatial resolution of 0.8 mm.
Characterization of HF Propagation for Digital Audio Broadcasting
NASA Technical Reports Server (NTRS)
Vaisnys, Arvydas
1997-01-01
The purpose of this presentation is to give a brief overview of some propagation measurements in the Short Wave (3-30 MHz) bands, made in support of a digital audio transmission system design for the Voice of America. This task is a follow on to the Digital Broadcast Satellite Radio task, during which several mitigation techniques would be applicable to digital audio in the Short Wave bands as well, in spite of the differences in propagation impairments in these two bands. Two series of propagation measurements were made to quantify the range of impairments that could be expected. An assessment of the performance of a prototype version of the receiver was also made.
NASA Astrophysics Data System (ADS)
Jara Casas, L. M.; Ceresa, D.; Kulis, S.; Miryala, S.; Christiansen, J.; Francisco, R.; Gnani, D.
2017-02-01
A Digital RADiation (DRAD) test chip has been specifically designed to study the impact of Total Ionizing Dose (TID) (<1 Grad) and Single Event Upset (SEU) on digital logic gates in a 65 nm CMOS technology. Nine different versions of standard cell libraries are studied in this chip, basically differing in the device dimensions, Vt flavor and layout of the device. Each library has eighteen test structures specifically designed to characterize delay degradation and power consumption of the standard cells. For SEU study, a dedicated test structure based on a shift register is designed for each library. TID results up to 500 Mrad are reported.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamilton, K.; Wilson, R.J.; Hemler, R.S.
1999-11-15
The large-scale circulation in the Geophysical Fluid Dynamics Laboratory SKYHI troposphere-stratosphere-mesosphere finite-difference general circulation model is examined as a function of vertical and horizontal resolution. The experiments examined include one with horizontal grid spacing of {approximately}35 km and another with {approximately}100 km horizontal grid spacing but very high vertical resolution (160 levels between the ground and about 85 km). The simulation of the middle-atmospheric zonal-mean winds and temperatures in the extratropics is found to be very sensitive to horizontal resolution. For example, in the early Southern Hemisphere winter the South Pole near 1 mb in the model is colder thanmore » observed, but the bias is reduced with improved horizontal resolution (from {approximately}70 C in a version with {approximately}300 km grid spacing to less than 10 C in the {approximately}35 km version). The extratropical simulation is found to be only slightly affected by enhancements of the vertical resolution. By contrast, the tropical middle-atmospheric simulation is extremely dependent on the vertical resolution employed. With level spacing in the lower stratosphere {approximately}1.5 km, the lower stratospheric zonal-mean zonal winds in the equatorial region are nearly constant in time. When the vertical resolution is doubled, the simulated stratospheric zonal winds exhibit a strong equatorially centered oscillation with downward propagation of the wind reversals and with formation of strong vertical shear layers. This appears to be a spontaneous internally generated oscillation and closely resembles the observed QBO in many respects, although the simulated oscillation has a period less than half that of the real QBO.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Chun; Leung, L. Ruby; Park, Sang-Hun
Advances in computing resources are gradually moving regional and global numerical forecasting simulations towards sub-10 km resolution, but global high resolution climate simulations remain a challenge. The non-hydrostatic Model for Prediction Across Scales (MPAS) provides a global framework to achieve very high resolution using regional mesh refinement. Previous studies using the hydrostatic version of MPAS (H-MPAS) with the physics parameterizations of Community Atmosphere Model version 4 (CAM4) found notable resolution dependent behaviors. This study revisits the resolution sensitivity using the non-hydrostatic version of MPAS (NH-MPAS) with both CAM4 and CAM5 physics. A series of aqua-planet simulations at global quasi-uniform resolutionsmore » ranging from 240 km to 30 km and global variable resolution simulations with a regional mesh refinement of 30 km resolution over the tropics are analyzed, with a primary focus on the distinct characteristics of NH-MPAS in simulating precipitation, clouds, and large-scale circulation features compared to H-MPAS-CAM4. The resolution sensitivity of total precipitation and column integrated moisture in NH-MPAS is smaller than that in H-MPAS-CAM4. This contributes importantly to the reduced resolution sensitivity of large-scale circulation features such as the inter-tropical convergence zone and Hadley circulation in NH-MPAS compared to H-MPAS. In addition, NH-MPAS shows almost no resolution sensitivity in the simulated westerly jet, in contrast to the obvious poleward shift in H-MPAS with increasing resolution, which is partly explained by differences in the hyperdiffusion coefficients used in the two models that influence wave activity. With the reduced resolution sensitivity, simulations in the refined region of the NH-MPAS global variable resolution configuration exhibit zonally symmetric features that are more comparable to the quasi-uniform high-resolution simulations than those from H-MPAS that displays zonal asymmetry in simulations inside the refined region. Overall, NH-MPAS with CAM5 physics shows less resolution sensitivity compared to CAM4. These results provide a reference for future studies to further explore the use of NH-MPAS for high-resolution climate simulations in idealized and realistic configurations.« less
Evaluating RGB photogrammetry and multi-temporal digital surface models for detecting soil erosion
NASA Astrophysics Data System (ADS)
Anders, Niels; Keesstra, Saskia; Seeger, Manuel
2013-04-01
Photogrammetry is a widely used tool for generating high-resolution digital surface models. Unmanned Aerial Vehicles (UAVs), equipped with a Red Green Blue (RGB) camera, have great potential in quickly acquiring multi-temporal high-resolution orthophotos and surface models. Such datasets would ease the monitoring of geomorphological processes, such as local soil erosion and rill formation after heavy rainfall events. In this study we test a photogrammetric setup to determine data requirements for soil erosion studies with UAVs. We used a rainfall simulator (5 m2) and above a rig with attached a Panasonic GX1 16 megapixel digital camera and 20mm lens. The soil material in the simulator consisted of loamy sand at an angle of 5 degrees. Stereo pair images were taken before and after rainfall simulation with 75-85% overlap. Acquired images were automatically mosaicked to create high-resolution orthorectified images and digital surface models (DSM). We resampled the DSM to different spatial resolutions to analyze the effect of cell size to the accuracy of measured rill depth and soil loss estimations, and determined an optimal cell size (thus flight altitude). Furthermore, the high spatial accuracy of the acquired surface models allows further analysis of rill formation and channel initiation related to e.g. surface roughness. We suggest implementing near-infrared and temperature sensors to combine soil moisture and soil physical properties with surface morphology for future investigations.
Continuous-tone applications in digital hard-copy output devices
NASA Astrophysics Data System (ADS)
Saunders, Jeffrey C.
1990-11-01
Dye diffusion technology has made a recent entry into the hardcopy printer arena making it now possible to achieve near-photographic quality images from digital raster image data. Whereas the majority of low cost printers utilizing ink-jet, thermal wax, or dotmatrix technologies advertise high resolution printheads, the restrictions which dithering algorithms apply to these inherently binary printing systems force them to sacrifice spatial resolution capability for tone scale reproduction. Dye diffusion technology allows a fully continuous range of density at each pixel location thus preserving the full spatial resolution capability of the printhead; spatial resolution is not sacrificed for tone scale. This results in images whose quality is far superior to the ink-jet or wax-transfer products; image quality so high in fact, to the unaided eye, dye diffusion images are indistinguishable from their silver-halide counterparts. Eastman Kodak Co. offers a highly refined application of dye diffusion technology in the Kodak XL 7700 Digital Continuous Tone Printer and Kodak EKTATHERM media products. The XL . 7700 Printer represents a serious alternative to expensive laser-based film recorders for applications which require high quality image output from digital data files. This paper presents an explanation of dye diffusion printing, what distinguishes it from other technologies, sensitometric control and image quality parameters, and applications within the industry, particularly that of Airborne Reconnaissance and Remote Sensing.
Digital Equipment Corporation VAX/VMS Version 4.3
1986-07-30
operating system performs process-oriented paging that allows execution of programs that may be larger than the physical memory allocated to them... to higher privileged modes. (For an explanation of how the four access modes provide memory access protection see page 9, "Memory Management".) A... to optimize program performance for real-time applications or interactive environments. July 30, 1986 - 4 - Final Evaluation Report Digital VAX/VMS
Systems Design Factors: The Essential Ingredients of System Design, Version 0.4
1994-03-18
Reliability Function). 4. Barry . W. Johnson, Design and Analysis of Fault Tolerant Digital Systems, p. 4, Addison- Wesley Publishing Company, 1985. METRICS...the system was performing correctly at time t. The unreliability is often referred to as the probability of failure. SOURCE: 1. Barry W. Johnson...Systems Enuineerinf. 3. Barry W. Johnson, Design and Analysis of Fault Tolerant Digital Systems, Addison-Wesley Publishing Company, 1985, p. 5
NASA Astrophysics Data System (ADS)
Arkadov, G. V.; Zhukavin, A. P.; Kroshilin, A. E.; Parshikov, I. A.; Solov'ev, S. L.; Shishov, A. V.
2014-10-01
The article describes the "Virtual Digital VVER-Based Nuclear Power Plant" computerized system comprising a totality of verified initial data (sets of input data for a model intended for describing the behavior of nuclear power plant (NPP) systems in design and emergency modes of their operation) and a unified system of new-generation computation codes intended for carrying out coordinated computation of the variety of physical processes in the reactor core and NPP equipment. Experiments with the demonstration version of the "Virtual Digital VVER-Based NPP" computerized system has shown that it is in principle possible to set up a unified system of computation codes in a common software environment for carrying out interconnected calculations of various physical phenomena at NPPs constructed according to the standard AES-2006 project. With the full-scale version of the "Virtual Digital VVER-Based NPP" computerized system put in operation, the concerned engineering, design, construction, and operating organizations will have access to all necessary information relating to the NPP power unit project throughout its entire lifecycle. The domestically developed commercial-grade software product set to operate as an independently operating application to the project will bring about additional competitive advantages in the modern market of nuclear power technologies.
Multiview boosting digital pathology analysis of prostate cancer.
Kwak, Jin Tae; Hewitt, Stephen M
2017-04-01
Various digital pathology tools have been developed to aid in analyzing tissues and improving cancer pathology. The multi-resolution nature of cancer pathology, however, has not been fully analyzed and utilized. Here, we develop an automated, cooperative, and multi-resolution method for improving prostate cancer diagnosis. Digitized tissue specimen images are obtained from 5 tissue microarrays (TMAs). The TMAs include 70 benign and 135 cancer samples (TMA1), 74 benign and 89 cancer samples (TMA2), 70 benign and 115 cancer samples (TMA3), 79 benign and 82 cancer samples (TMA4), and 72 benign and 86 cancer samples (TMA5). The tissue specimen images are segmented using intensity- and texture-based features. Using the segmentation results, a number of morphological features from lumens and epithelial nuclei are computed to characterize tissues at different resolutions. Applying a multiview boosting algorithm, tissue characteristics, obtained from differing resolutions, are cooperatively combined to achieve accurate cancer detection. In segmenting prostate tissues, the multiview boosting method achieved≥ 0.97 AUC using TMA1. For detecting cancers, the multiview boosting method achieved an AUC of 0.98 (95% CI: 0.97-0.99) as trained on TMA2 and tested on TMA3, TMA4, and TMA5. The proposed method was superior to single-view approaches, utilizing features from a single resolution or merging features from all the resolutions. Moreover, the performance of the proposed method was insensitive to the choice of the training dataset. Trained on TMA3, TMA4, and TMA5, the proposed method obtained an AUC of 0.97 (95% CI: 0.96-0.98), 0.98 (95% CI: 0.96-0.99), and 0.97 (95% CI: 0.96-0.98), respectively. The multiview boosting method is capable of integrating information from multiple resolutions in an effective and efficient fashion and identifying cancers with high accuracy. The multiview boosting method holds a great potential for improving digital pathology tools and research. Copyright © 2017 Elsevier B.V. All rights reserved.
1988-01-04
Controller Routine .......... ........................ 405 -viii- ’ O, ...1 . • N SList of Illustrations i p List of Illustrations . Fig. 1: A...J------ - - - 6 - -- -w -- -w -r n . w ~ - P a CGCS Program Versions ~CGCS Program Versions This section describes the "evolution" of the...8217 ~- 134 - ,d" - 1’ , n "W , ’." " a 4 r P . ’ ,’ r t r 1 "."." , . L t * 5.1 CGCS Concept and Structure 5. The Czochralski Growth Control System Software
Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.
NASA Astrophysics Data System (ADS)
Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David
1989-05-01
The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.
Lithology and aggregate quality attributes for the digital geologic map of Colorado
Knepper, Daniel H.; Green, Gregory N.; Langer, William H.
1999-01-01
This geologic map was prepared as a part of a study of digital methods and techniques as applied to complex geologic maps. The geologic map was digitized from the original scribe sheets used to prepare the published Geologic Map of Colorado (Tweto 1979). Consequently the digital version is at 1:500,000 scale using the Lambert Conformal Conic map projection parameters of the state base map. Stable base contact prints of the scribe sheets were scanned on a Tektronix 4991 digital scanner. The scanner automatically converts the scanned image to an ASCII vector format. These vectors were transferred to a VAX minicomputer, where they were then loaded into ARC/INFO. Each vector and polygon was given attributes derived from the original 1979 geologic map.
Orchard, John; Rae, Katherine; Brooks, John; Hägglund, Martin; Til, Lluis; Wales, David; Wood, Tim
2010-01-01
The Orchard Sports Injury Classification System (OSICS) is one of the world’s most commonly used systems for coding injury diagnoses in sports injury surveillance systems. Its major strengths are that it has wide usage, has codes specific to sports medicine and that it is free to use. Literature searches and stakeholder consultations were made to assess the uptake of OSICS and to develop new versions. OSICS was commonly used in the sports of football (soccer), Australian football, rugby union, cricket and tennis. It is referenced in international papers in three sports and used in four commercially available computerised injury management systems. Suggested injury categories for the major sports are presented. New versions OSICS 9 (three digit codes) and OSICS 10.1 (four digit codes) are presented. OSICS is a potentially helpful component of a comprehensive sports injury surveillance system, but many other components are required. Choices made in developing these components should ideally be agreed upon by groups of researchers in consensus statements. PMID:24198559
NASA Astrophysics Data System (ADS)
Bilki, Burak
2018-03-01
The Particle Flow Algorithms attempt to measure each particle in a hadronic jet individually, using the detector providing the best energy/momentum resolution. Therefore, the spatial segmentation of the calorimeter plays a crucial role. In this context, the CALICE Collaboration developed the Digital Hadron Calorimeter. The Digital Hadron Calorimeter uses Resistive Plate Chambers as active media and has a 1-bit resolution (digital) readout of 1 × 1 cm2 pads. The calorimeter was tested with steel and tungsten absorber structures, as well as with no absorber structure, at the Fermilab and CERN test beam facilities over several years. In addition to conventional calorimetric measurements, the Digital Hadron Calorimeter offers detailed measurements of event shapes, rigorous tests of simulation models and various tools for improved performance due to its very high spatial granularity. Here we report on the results from the analysis of pion and positron events. Results of comparisons with the Monte Carlo simulations are also discussed. The analysis demonstrates the unique utilization of detailed event topologies.
NASA Astrophysics Data System (ADS)
Jančář, A.; Kopecký, Z.; Dressler, J.; Veškrna, M.; Matěj, Z.; Granja, C.; Solar, M.
2015-11-01
Recently invented plastic scintillator EJ-299-33 enables pulse-shape discrimination (PSD) and thus measurement of neutron and photon spectra in mixed fields. In this work we compare the PSD properties of EJ-299-33 plastic and the well-known NE-213 liquid scintillator in monoenergetic neutron fields generated by the Van de Graaff accelerator using the 3H(d, n)4He reaction. Pulses from the scintillators are processed by a newly developed digital measuring system employing the fast digitizer card. This card contains two AD converters connected to the measuring computer via 10 Gbps optical ethernet. The converters operate with a resolution of 12 bits and have two differential inputs with a sampling frequency 1 GHz. The resulting digital channels with different gains are merged into one composite channel with a higher digital resolution in a wide dynamic range of energies. Neutron signals are fully discriminated from gamma signals. Results are presented.
NASA Astrophysics Data System (ADS)
Kwon, N.; Gentle, J.; Pierce, S. A.
2015-12-01
Software code developed for research is often used for a relatively short period of time before it is abandoned, lost, or becomes outdated. This unintentional abandonment of code is a valid problem in the 21st century scientific process, hindering widespread reusability and increasing the effort needed to develop research software. Potentially important assets, these legacy codes may be resurrected and documented digitally for long-term reuse, often with modest effort. Furthermore, the revived code may be openly accessible in a public repository for researchers to reuse or improve. For this study, the research team has begun to revive the codebase for Groundwater Decision Support System (GWDSS), originally developed for participatory decision making to aid urban planning and groundwater management, though it may serve multiple use cases beyond those originally envisioned. GWDSS was designed as a java-based wrapper with loosely federated commercial and open source components. If successfully revitalized, GWDSS will be useful for both practical applications as a teaching tool and case study for groundwater management, as well as informing theoretical research. Using the knowledge-sharing approaches documented by the NSF-funded Ontosoft project, digital documentation of GWDSS is underway, from conception to development, deployment, characterization, integration, composition, and dissemination through open source communities and geosciences modeling frameworks. Information assets, documentation, and examples are shared using open platforms for data sharing and assigned digital object identifiers. Two instances of GWDSS version 3.0 are being created: 1) a virtual machine instance for the original case study to serve as a live demonstration of the decision support tool, assuring the original version is usable, and 2) an open version of the codebase, executable installation files, and developer guide available via an open repository, assuring the source for the application is accessible with version control and potential for new branch developments. Finally, metadata about the software has been completed within the OntoSoft portal to provide descriptive curation, make GWDSS searchable, and complete documentation of the scientific software lifecycle.
Remmersmann, Christian; Stürwald, Stephan; Kemper, Björn; Langehanenberg, Patrik; von Bally, Gert
2009-03-10
In temporal phase-shifting-based digital holographic microscopy, high-resolution phase contrast imaging requires optimized conditions for hologram recording and phase retrieval. To optimize the phase resolution, for the example of a variable three-step algorithm, a theoretical analysis on statistical errors, digitalization errors, uncorrelated errors, and errors due to a misaligned temporal phase shift is carried out. In a second step the theoretically predicted results are compared to the measured phase noise obtained from comparative experimental investigations with several coherent and partially coherent light sources. Finally, the applicability for noise reduction is demonstrated by quantitative phase contrast imaging of pancreas tumor cells.
Optimization of Energy Resolution in the Digital Hadron Calorimeter using Longitudinal Weights
NASA Astrophysics Data System (ADS)
Smith, J. R.; Bilki, B.; Francis, K.; Repond, J.; Schlereth, J.; Xia, L.
2013-04-01
Physics at a future lepton collider requires unprecedented jet energy and dijet mass resolutions. Particle Flow Algorithms (PFAs) have been proposed to achieve these. PFAs measure particles in a jet individually with the detector subsystem providing the best resolution. For this to work a calorimeter system with very high granularity is required. A prototype Digital Hadron Calorimeter (the DHCAL) based on the Resistive Plate Chamber (RPC) technology with a record count of readout channels has been developed, constructed, and exposed to particle beams. In this context, we report on a technique to improve the single hadron energy resolution by applying a set of calibration weights to the individual layers of the calorimeter. This weighting procedure was applied to approximately 1 million events in the energy range up to 60 GeV and shows an improvement in the pion energy resolution. Simulated data is used to verify particle identification techniques and to compare with the data.
Body as Echoes: Cyber Archiving of Dazu Rock Carvings
NASA Astrophysics Data System (ADS)
Chen, W.-W.
2017-08-01
"Body As Echoes: Cyber Archiving of Dazu Rock Carvings (BAE project in short)" strives to explore the tangible/intangible aspects of digital heritage conservation. Aiming at Dazu Rock Carvings - World Heritage Site of Sichuan Province, BAE project utilizes photogrammetry and digital sculpting technique to investigate digital narrative of cultural heritage conservation. It further provides collaborative opportunities to conduct the high-resolution site survey for scholars and institutions at local authorities. For preserving and making sustainable of the tangible cultural heritage at Dazu Rock Carvings, BAE project cyber-archives the selected niches and the caves at Dazu, and transform them into high-resolution, three-dimensional models. For extending the established results and making the digital resources available to broader audiences, BAE project will further develop interactive info-motion interface and apply the knowledge of digital heritage from BAE project to STEM education. BAE project expects to bridge the platform for archeology, computer graphics, and interactive info-motion design. Digital sculpting, projection mapping, interactive info-motion and VR will be the core techniques to explore the narrative of digital heritage conservation. For further protecting, educating and consolidating "building dwelling thinking" through digital heritage preservation, BAE project helps to preserve the digital humanity, and reach out to museum staffs and academia. By the joint effort of global institutions and local authorities, BAE project will also help to foster and enhance the mutual understanding through intercultural collaborations.
A multi-threshold sampling method for TOF-PET signal processing
NASA Astrophysics Data System (ADS)
Kim, H.; Kao, C. M.; Xie, Q.; Chen, C. T.; Zhou, L.; Tang, F.; Frisch, H.; Moses, W. W.; Choong, W. S.
2009-04-01
As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multi-threshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to eight threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25×6.25×25 mm3 LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an ˜18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an ˜9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain ˜300 ps coincidence timing resolution, ˜14% energy resolution at 511 keV, and ˜5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.
Topographic correction realization based on the CBERS-02B image
NASA Astrophysics Data System (ADS)
Qin, Hui-ping; Yi, Wei-ning; Fang, Yong-hua
2011-08-01
The special topography of mountain terrain will induce the retrieval distortion in same species and surface spectral lines. In order to improve the research accuracy of topographic surface characteristic, many researchers have focused on topographic correction. Topographic correction methods can be statistical-empirical model or physical model, in which the methods based on the digital elevation model data are most popular. Restricted by spatial resolution, previous model mostly corrected topographic effect based on Landsat TM image, whose spatial resolution is 30 meter that can be easily achieved from internet or calculated from digital map. Some researchers have also done topographic correction based on high spatial resolution images, such as Quickbird and Ikonos, but there is little correlative research on the topographic correction of CBERS-02B image. In this study, liao-ning mountain terrain was taken as the objective. The digital elevation model data was interpolated to 2.36 meter by 15 meter original digital elevation model one meter by one meter. The C correction, SCS+C correction, Minnaert correction and Ekstrand-r were executed to correct the topographic effect. Then the corrected results were achieved and compared. The images corrected with C correction, SCS+C correction, Minnaert correction and Ekstrand-r were compared, and the scatter diagrams between image digital number and cosine of solar incidence angel with respect to surface normal were shown. The mean value, standard variance, slope of scatter diagram, and separation factor were statistically calculated. The analysed result shows that the shadow is weakened in corrected images than the original images, and the three-dimensional affect is removed. The absolute slope of fitting lines in scatter diagram is minished. Minnaert correction method has the most effective result. These demonstrate that the former correction methods can be successfully adapted to CBERS-02B images. The DEM data can be interpolated step by step to get the corresponding spatial resolution approximately for the condition that high spatial resolution elevation data is hard to get.
Schulz-Wendtland, R; Hermann, K-P; Adamietz, B; Meier-Meitinger, M; Wenkel, E; Lell, M; Anders, K; Uder, M
2011-02-01
The aim of this retrospective clinical study was to compare the diagnostic accuracy of the novel 50 µm FFDM (full-field digital mammography) system (DR) with an established 70 µm system (DR) in the differential diagnosis between benign and malignant clusters of microcalcification (n=50) (BI-RADS™ classification 4/5) and to assess the possible incremental value of the 50 µm pixel-pitch on specificity. From March 2009 to September 2009, 50 patients underwent full-field digital mammography (FFDM) (detector resolution 70 µm) (Novation, Siemens, Erlangen, Germany). As there were suspicious signs of microcalcification classified with BI-RADS™ 4/5 after diagnosis and preoperative wire localization, control images were made with the new FFDM system (detector: resolution 50 µm) (Amulet, Fujifilm, Tokyo, Japan) with the same exposure parameters. The diagnosis was determined after the operation by five radiologists with different experience in digital mammography from randomly distributed mediolateral views (monitor reading) whose results were correlated with the final histology of all lesions. Histopathology revealed 19 benign and 31 malignant lesions in 50 patients after open biopsy. The results of the five readers showed a higher sensitivity of the new FFDM system (80.0%) in the ability to recognize malignant microcalcification in comparison to the established system (74.8%). The specificity (75.8 versus 71.6%) was slightly higher for the new system but these results were not statistically significant (p<0.001). Considering the diagnostic accuracy, the new system (detector: resolution 50 µm) was also slightly superior to the well-known system (detector: resolution 70 µm) (80.1% versus 76.4%). Our study has shown that the new full-field digital mammography system using the novel detector compared with the already established FFDM system with respect to the assessment of microcalcification is at least equivalent.
Poppenga, Sandra K.; Worstell, Bruce B.; Stoker, Jason M.; Greenlee, Susan K.
2010-01-01
Digital elevation data commonly are used to extract surface flow features. One source for high-resolution elevation data is light detection and ranging (lidar). Lidar can capture a vast amount of topographic detail because of its fine-scale ability to digitally capture the surface of the earth. Because elevation is a key factor in extracting surface flow features, high-resolution lidar-derived digital elevation models (DEMs) provide the detail needed to consistently integrate hydrography with elevation, land cover, structures, and other geospatial features. The U.S. Geological Survey has developed selective drainage methods to extract continuous surface flow from high-resolution lidar-derived digital elevation data. The lidar-derived continuous surface flow network contains valuable information for water resource management involving flood hazard mapping, flood inundation, and coastal erosion. DEMs used in hydrologic applications typically are processed to remove depressions by filling them. High-resolution DEMs derived from lidar can capture much more detail of the land surface than courser elevation data. Therefore, high-resolution DEMs contain more depressions because of obstructions such as roads, railroads, and other elevated structures. The filling of these depressions can significantly affect the DEM-derived surface flow routing and terrain characteristics in an adverse way. In this report, selective draining methods that modify the elevation surface to drain a depression through an obstruction are presented. If such obstructions are not removed from the elevation data, the filling of depressions to create continuous surface flow can cause the flow to spill over an obstruction in the wrong location. Using this modified elevation surface improves the quality of derived surface flow and retains more of the true surface characteristics by correcting large filled depressions. A reliable flow surface is necessary for deriving a consistently connected drainage network, which is important in understanding surface water movement and developing applications for surface water runoff, flood inundation, and erosion. Improved methods are needed to extract continuous surface flow features from high-resolution elevation data based on lidar.
The DBBC environment for millimeter radioastronomy
NASA Astrophysics Data System (ADS)
Tuccari, Gino; Comoretto, Giovanni; Melis, Andrea; Buttaccio, Salvo
2012-09-01
The Digital Base Band Converter project developed in the last decade produced a general architecture and a class of boards, firmware and software, giving the possibility to build a general purpose back-end system for VLBI or single-dish observational activities. Such approach suggests the realization of a digital radio system, i.e. a receiver with conversion not realized with analogue techniques, maintaining only amplification stages in the analogue domain. This solution can be applied until a maximum around 16 GHz, the present limit for the instantaneous input band in the latest version of the DBBC project, while in the millimeter frequency range this maximum limit of 0.5-2 GHz of the previous versions allows the intermediate frequency to be processed in the digital domain. A description of the elements developed in the DBBC project is presented, with their use in different environments. The architecture is composed of a PC controlled mainframe, and of different modules that can be combined in a very flexible way in order to realize different instruments. The instrument can be expanded or retrofitted to meet increasing observational demands. Available modules include ADC converters, processing boards, physical interfaces (VSI and 10G Ethernet). Several applications have already been implemented and used in radioastronomic observations: a DDC (Direct Digital Conversion) for VLBI observations, a Polyphase Digital Filter Bank, and a Multiband Scansion Spectrometer. Other applications are currently studied for additional functionalities like a spectropolarimeter, a linear-to-circular polarization converter, a RFI-mitigation tool, and a phase-reference holographic tool-kit.
Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts
NASA Technical Reports Server (NTRS)
Grau, David
2012-01-01
This process is designed to estimate the thickness change of a material through data analysis of a digitized version of an x-ray (or a digital x-ray) containing the material (with the thickness in question) and various tooling. Using this process, it is possible to estimate a material's thickness change in a region of the material or part that is thinner than the rest of the reference thickness. However, that same principle process can be used to determine the thickness change of material using a thinner region to determine thickening, or it can be used to develop contour plots of an entire part. Proper tooling must be used. An x-ray film with an S-shaped characteristic curve or a digital x-ray device with a product resulting in like characteristics is necessary. If a film exists with linear characteristics, this type of film would be ideal; however, at the time of this reporting, no such film has been known. Machined components (with known fractional thicknesses) of a like material (similar density) to that of the material to be measured are necessary. The machined components should have machined through-holes. For ease of use and better accuracy, the throughholes should be a size larger than 0.125 in. (.3 mm). Standard components for this use are known as penetrameters or image quality indicators. Also needed is standard x-ray equipment, if film is used in place of digital equipment, or x-ray digitization equipment with proven conversion properties. Typical x-ray digitization equipment is commonly used in the medical industry, and creates digital images of x-rays in DICOM format. It is recommended to scan the image in a 16-bit format. However, 12-bit and 8-bit resolutions are acceptable. Finally, x-ray analysis software that allows accurate digital image density calculations, such as Image-J freeware, is needed. The actual procedure requires the test article to be placed on the raw x-ray, ensuring the region of interest is aligned for perpendicular x-ray exposure capture. One or multiple machined components of like material/ density with known thicknesses are placed atop the part (preferably in a region of nominal and non-varying thickness) such that exposure of the combined part and machined component lay-up is captured on the x-ray. Depending on the accuracy required, the machined component fs thickness must be carefully chosen. Similarly, depending on the accuracy required, the lay-up must be exposed such that the regions of the x-ray to be analyzed have a density range between 1 and 4.5. After the exposure, the image is digitized, and the digital image can then be analyzed using the image analysis software.
Multiple-access phased array antenna simulator for a digital beam-forming system investigation
NASA Technical Reports Server (NTRS)
Kerczewski, Robert J.; Yu, John; Walton, Joanne C.; Perl, Thomas D.; Andro, Monty; Alexovich, Robert E.
1992-01-01
Future versions of data relay satellite systems are currently being planned by NASA. Being given consideration for implementation are on-board digital beamforming techniques which will allow multiple users to simultaneously access a single S-band phased array antenna system. To investigate the potential performance of such a system, a laboratory simulator has been developed at NASA's Lewis Research Center. This paper describes the system simulator, and in particular, the requirements, design and performance of a key subsystem, the phased array antenna simulator, which provides realistic inputs to the digital processor including multiple signals, noise, and nonlinearities.
Multiple-access phased array antenna simulator for a digital beam forming system investigation
NASA Technical Reports Server (NTRS)
Kerczewski, Robert J.; Yu, John; Walton, Joanne C.; Perl, Thomas D.; Andro, Monty; Alexovich, Robert E.
1992-01-01
Future versions of data relay satellite systems are currently being planned by NASA. Being given consideration for implementation are on-board digital beamforming techniques which will allow multiple users to simultaneously access a single S-band phased array antenna system. To investigate the potential performance of such a system, a laboratory simulator has been developed at NASA's Lewis Research Center. This paper describes the system simulator, and in particular, the requirements, design, and performance of a key subsystem, the phased array antenna simulator, which provides realistic inputs to the digital processor including multiple signals, noise, and nonlinearities.
Digital processing of Mariner 9 television data.
NASA Technical Reports Server (NTRS)
Green, W. B.; Seidman, J. B.
1973-01-01
The digital image processing performed by the Image Processing Laboratory (IPL) at JPL in support of the Mariner 9 mission is summarized. The support is divided into the general categories of image decalibration (the removal of photometric and geometric distortions from returned imagery), computer cartographic projections in support of mapping activities, and adaptive experimenter support (flexible support to provide qualitative digital enhancements and quantitative data reduction of returned imagery). Among the tasks performed were the production of maximum discriminability versions of several hundred frames to support generation of a geodetic control net for Mars, and special enhancements supporting analysis of Phobos and Deimos images.
Position paper: recommendations for a digital mammography quality assurance program V4.0.
Heggie, J C P; Barnes, P; Cartwright, L; Diffey, J; Tse, J; Herley, J; McLean, I D; Thomson, F J; Grewal, R K; Collins, L T
2017-09-01
In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation of digital mammography has been realised and it has become evident that existing screen-film protocols were not appropriate to assure the required image quality needed for reliable diagnosis or to address the new dose implications resulting from digital technology. In addition, the advantages and responsibilities inherent in teleradiology are most critical in mammography and also need to be addressed. The current document is the result of a review of current overseas practice and local experience in these areas. At this time the technology of digital imaging is undergoing significant development and there is still a lack of full international consensus about some of the detailed quality control (QC) tests that should be included in quality assurance (QA) programs. This document describes the current status in digital mammography QA and recommends test procedures that may be suitable in the Australasian environment. For completeness, this document also includes a review of the QA programs required for the various types of digital biopsy units used in mammography. In the future, international harmonisation of digital quality assurance in mammography and changes in the technology may require a review of this document. Version 2.0 represented the first of these updates and key changes related to image quality evaluation, ghost image evaluation and interpretation of signal to noise ratio measurements. In Version 3.0 some significant changes, made in light of further experience gained in testing digital mammography equipment were introduced. In Version 4.0, further changes have been made, most notably digital breast tomosynthesis (DBT) testing and QC have been addressed. Some additional testing for conventional projection imaging has been added in order that sites may have the capability to undertake dose surveys to confirm compliance with diagnostic reference levels (DRLs) that may be established at the National or State level. A key recommendation is that dosimetry calculations are now to be undertaken using the methodology of Dance et al. Some minor changes to existing facility QC tests have been made to ensure the suggested procedures align with those most recently adopted by the Royal Australian and New Zealand College of Radiologists and BreastScreen Australia. Future updates of this document may be provided as deemed necessary in electronic format on the ACPSEM's website ( https://www.acpsem.org.au/whatacpsemdoes/standards-position-papers and see also http://www.ranzcr.edu.au/quality-a-safety/radiology/practice-quality-activities/mqap ).
Ultra-Wideband Radars for Measurements over Land and Sea Ice
NASA Astrophysics Data System (ADS)
Gogineni, S.; Hale, R.; Miller, H. G.; Yan, S.; Rodriguez-Morales, F.; Leuschen, C.; Wang, Z.; Gomez-Garcia, D.; Binder, T.; Steinhage, D.; Gehrmann, M.; Braaten, D. A.
2015-12-01
We developed two ultra-wideband (UWB) radars for measurements over the ice sheets in Greenland and Antarctica and sea ice. One of the UWB radars operates over a 150-600 MHz frequency range with a large, cross-track 24-element array. It is designed to sound ice, image the ice-bed interface, and map internal layers with fine resolution. The 24-element array consists of three 8-element sub-arrays. One of these sub-arrays is mounted under the fuselage of a BT-67 aircraft; the other two are mounted under the wings. The polarization of each antenna element can be individually reconfigured depending on the target of interest. The measured inflight VSWR is less than 2 over the operating range. The fuselage sub-array is used both for transmission and reception, and the wing-mounted sub-arrays are used for reception. The transmitter consists of an 8-channel digital waveform generator to synthesize chirped pulses of selectable pulse width, duration, and bandwidth. It also consists of drivers and power amplifiers to increase the power level of each individual channel to about 1 kW and a fast high-power transmit/receive switch. Each receiver consists of a limiter, switches, low-noise and driver amplifiers, and filters to shape and amplify received signals to the level required for digitization. The digital sub-section consists of timing and control sub-systems and 24 14-bit A/D converters to digitize received signals at a rate of 1.6 GSPS. The radar performance is evaluated using an optical delay line to simulate returns from about 2 km thick ice, and the measured radar loop sensitivity is about 215 dB. The other UWB microwave radar operates over a 2-18 GHz frequency range in Frequency-Modulated Continuous Wave (FM-CW) mode. It is designed to sound more than 1 m of snow over sea ice and map internal layers to a depth about 25-40 m in polar firn and ice. We operated the microwave radar over snow-covered sea ice and mapped snow as thin as 5 cm and as thick as 60 cm. We mapped internal layers with an early version of the radar to a depth of 45 m with fine resolution in West Antarctica. In this presentation, we will discuss design considerations and present laboratory results to document radar performance, including the impulse response functions. We will also show the results from a field campaign over the Greenland ice sheet.
Dagik Earth: A Digital Globe Project for Classrooms, Science Museums, and Research Institutes
NASA Astrophysics Data System (ADS)
Saito, A.; Tsugawa, T.
2017-12-01
Digital globe system is a powerful tool to make the audiences understand phenomena on the Earth and planets in intuitive way. Geo-cosmos of Miraikan, Japan uses 6-m spherical LED, and is one of the largest systems of digital globe. Science on a Sphere (SOS) by NOAA is a digital globe system that is most widely used in science museums around the world. These systems are so expensive that the usage of the digital globes is mainly limited to large-scale science museums. Dagik Earth is a digital globe project that promotes educational programs using digital globe with low cost. It aims to be used especially in classrooms. The cost for the digital globe of Dagik Earth is from several US dollars if PC and PC projector are available. It uses white spheres, such as balloons and balance balls, as the screen. The software is provided by the project with free of charge for the educational usage. The software runs on devices of Windows, Mac and iOS. There are English and Chinese language versions of the PC software besides Japanese version. The number of the registered users of Dagik Earth is about 1,400 in Japan. About 60% of them belongs to schools, 30% to universities and research institutes, and 8% to science museums. In schools, it is used in classes by teachers, and science activities by students. Several teachers have used the system for five years and more. In a students' activity, Dagik Earth contents on the typhoon, solar eclipse, and satellite launch were created and presented in a school festival. This is a good example of the usage of Dagik Earth for STEM education. In the presentation, the system and activity of Dagik Earth will be presented, and the future expansion of the project will be discussed.
Derivation of planetary topography using multi-image shape-from-shading
Lohse, V.; Heipke, C.; Kirk, R.L.
2006-01-01
In many cases, the derivation of high-resolution digital terrain models (DTMs) from planetary surfaces using conventional digital image matching is a problem. The matching methods need at least one stereo pair of images with sufficient texture. However, many space missions provide only a few stereo images and planetary surfaces often possess insufficient texture. This paper describes a method for the generation of high-resolution DTMs from planetary surfaces, which has the potential to overcome the described problem. The suggested method, developed by our group, is based on shape-from-shading using an arbitrary number of digital optical images, and is termed "multi-image shape-from-shading" (MI-SFS). The paper contains an explanation of the theory of MI-SFS, followed by a presentation of current results, which were obtained using images from NASA's lunar mission Clementine, and constitute the first practical application with our method using extraterrestrial imagery. The lunar surface is reconstructed under the assumption of different kinds of reflectance models (e.g. Lommel-Seeliger and Lambert). The represented results show that the derivation of a high-resolution DTM of real digital planetary images by means of MI-SFS is feasible. ?? 2006 Elsevier Ltd. All rights reserved.
Publisher Correction: Quantum engineering of transistors based on 2D materials heterostructures
NASA Astrophysics Data System (ADS)
Iannaccone, Giuseppe; Bonaccorso, Francesco; Colombo, Luigi; Fiori, Gianluca
2018-06-01
In the version of this Perspective originally published, in the email address for the author Giuseppe Iannaccone, the surname was incorrectly given as "innaconne"; this has now been corrected in all versions of the Perspective. Also, an error in the production process led to Figs. 1, 2 and 3 being of low resolution; these have now been replaced with higher-quality versions.
Kim, Soon Hee; Yeon, Yeung Kyu; Lee, Jung Min; Chao, Janet Ren; Lee, Young Jin; Seo, Ye Been; Sultan, Md Tipu; Lee, Ok Joo; Lee, Ji Seung; Yoon, Sung-Il; Hong, In-Sun; Khang, Gilson; Lee, Sang Jin; Yoo, James J; Park, Chan Hum
2018-06-11
The original version of this Article contained errors in Figs. 5 and 6. In Fig. 5b, the second panel on the bottom row was stretched out of proportion. In Fig. 6d, the first panel was also stretched out of proportion. In Fig. 6f, the fifth panel inadvertently repeated the fourth. This has been corrected in both the PDF and HTML versions of the Article.
Dibblee, T. W.; Digital database compiled by Graham, S. E.; Mahony, T.M.; Blissenbach, J.L.; Mariant, J.J.; Wentworth, C.M.
1999-01-01
This Open-File Report is a digital geologic map database. The report serves to introduce and describe the digital data. There is no paper map included in the Open-File Report. The report includes PostScript and PDF plot files that can be used to plot images of the geologic map sheet and explanation sheet. This digital map database is prepared from a previously published map by Dibblee (1973). The geologic map database delineates map units that are identified by general age, lithology, and clast size following the stratigraphic nomenclature of the U.S. Geological Survey. For descriptions of the units, their stratigraphic relations, and sources of geologic mapping, consult the explanation sheet (of99-14_4b.ps or of99-14_4d.pdf), or the original published paper map (Dibblee, 1973). The scale of the source map limits the spatial resolution (scale) of the database to 1:125,000 or smaller. For those interested in the geology of Carrizo Plain and vicinity who do not use an ARC/INFO compatible Geographic Information System (GIS), but would like to obtain a paper map and explanation, PDF and PostScript plot files containing map images of the data in the digital database, as well as PostScript and PDF plot files of the explanation sheet and explanatory text, have been included in the database package (please see the section 'Digital Plot Files', page 5). The PostScript plot files require a gzip utility to access them. For those without computer capability, we can provide users with the PostScript or PDF files on tape that can be taken to a vendor for plotting. Paper plots can also be ordered directly from the USGS (please see the section 'Obtaining Plots from USGS Open-File Services', page 5). The content and character of the database, methods of obtaining it, and processes of extracting the map database from the tar (tape archive) file are described herein. The map database itself, consisting of six ARC/INFO coverages, can be obtained over the Internet or by magnetic tape copy as described below. The database was compiled using ARC/INFO, a commercial Geographic Information System (Environmental Systems Research Institute, Redlands, California), with version 3.0 of the menu interface ALACARTE (Fitzgibbon and Wentworth, 1991, Fitzgibbon, 1991, Wentworth and Fitzgibbon, 1991). The ARC/INFO coverages are stored in uncompressed ARC export format (ARC/INFO version 7.x). All data files have been compressed, and may be uncompressed with gzip, which is available free of charge over the Internet via links from the USGS Public Domain Software page (http://edcwww.cr.usgs.gov/doc/edchome/ndcdb/public.html). ARC/INFO export files (files with the .e00 extension) can be converted into ARC/INFO coverages in ARC/INFO (see below) and can be read by some other Geographic Information Systems, such as MapInfo via ArcLink and ESRI's ArcView.
Improvement of the energy resolution via an optimized digital signal processing in GERDA Phase I
NASA Astrophysics Data System (ADS)
Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Barros, N.; Baudis, L.; Bauer, C.; Becerici-Schmidt, N.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Budjáš, D.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Vacri, A. di; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Fedorova, O.; Freund, K.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hegai, A.; Heisel, M.; Hemmer, S.; Heusser, G.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Klimenko, A.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, ********************M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schütz, A.-K.; Schulz, O.; Schwingenheuer, B.; Selivanenko, O.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Stepaniuk, M.; Ur, C. A.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Walter, M.; Wegmann, A.; Wester, T.; Wilsenach, H.; Wojcik, M.; Yanovich, E.; Zavarise, P.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.
2015-06-01
An optimized digital shaping filter has been developed for the Gerda experiment which searches for neutrinoless double beta decay in Ge. The Gerda Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) corresponding to 10 % at the value for decay in Ge is obtained. This is possible thanks to the enhanced low-frequency noise rejection of this Zero Area Cusp (ZAC) signal shaping filter.
Color lensless digital holographic microscopy with micrometer resolution.
Garcia-Sucerquia, Jorge
2012-05-15
Color digital lensless holographic microscopy with micrometer resolution is presented. Multiwavelength illumination of a biological sample and a posteriori color composition of the amplitude images individually reconstructed are used to obtain full-color representation of the microscopic specimen. To match the sizes of the reconstructed holograms for each wavelength, a reconstruction algorithm that allows for choosing the pixel size at the reconstruction plane independently of the wavelength and the reconstruction distance is used. The method is illustrated with experimental results.
Digital holographic interferometry for characterizing deformable mirrors in aero-optics
NASA Astrophysics Data System (ADS)
Trolinger, James D.; Hess, Cecil F.; Razavi, Payam; Furlong, Cosme
2016-08-01
Measuring and understanding the transient behavior of a surface with high spatial and temporal resolution are required in many areas of science. This paper describes the development and application of a high-speed, high-dynamic range, digital holographic interferometer for high-speed surface contouring with fractional wavelength precision and high-spatial resolution. The specific application under investigation here is to characterize deformable mirrors (DM) employed in aero-optics. The developed instrument was shown capable of contouring a deformable mirror with extremely high-resolution at frequencies exceeding 40 kHz. We demonstrated two different procedures for characterizing the mechanical response of a surface to a wide variety of input forces, one that employs a high-speed digital camera and a second that employs a low-speed, low-cost digital camera. The latter is achieved by cycling the DM actuators with a step input, producing a transient that typically lasts up to a millisecond before reaching equilibrium. Recordings are made at increasing times after the DM initiation from zero to equilibrium to analyze the transient. Because the wave functions are stored and reconstructable, they can be compared with each other to produce contours including absolute, difference, and velocity. High-speed digital cameras recorded the wave functions during a single transient at rates exceeding 40 kHz. We concluded that either method is fully capable of characterizing a typical DM to the extent required by aero-optical engineers.
In-depth study of single photon time resolution for the Philips digital silicon photomultiplier
NASA Astrophysics Data System (ADS)
Liu, Z.; Gundacker, S.; Pizzichemi, M.; Ghezzi, A.; Auffray, E.; Lecoq, P.; Paganoni, M.
2016-06-01
The digital silicon photomultiplier (SiPM) has been commercialised by Philips as an innovative technology compared to analog silicon photomultiplier devices. The Philips digital SiPM, has a pair of time to digital converters (TDCs) connected to 12800 single photon avalanche diodes (SPADs). Detailed measurements were performed to understand the low photon time response of the Philips digital SiPM. The single photon time resolution (SPTR) of every single SPAD in a pixel consisting of 3200 SPADs was measured and an average value of 85 ps full width at half maximum (FWHM) was observed. Each SPAD sends the signal to the TDC with different signal propagation time, resulting in a so called trigger network skew. This distribution of the trigger network skew for a pixel (3200 SPADs) has been measured and a variation of 50 ps FWHM was extracted. The SPTR of the whole pixel is the combination of SPAD jitter, trigger network skew, and the SPAD non-uniformity. The SPTR of a complete pixel was 103 ps FWHM at 3.3 V above breakdown voltage. Further, the effect of the crosstalk at a low photon level has been studied, with the two photon time resolution degrading if the events are a combination of detected (true) photons and crosstalk events. Finally, the time response to multiple photons was investigated.
X-Ray Computed Tomography Monitors Damage in Composites
NASA Technical Reports Server (NTRS)
Baaklini, George Y.
1997-01-01
The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.
NASA Astrophysics Data System (ADS)
Singh, Kundan; Siwal, Davinder
2018-04-01
A digital timing algorithm is explored for fast scintillator detectors, viz. LaBr3, BaF2, and BC501A. Signals were collected with CAEN 250 mega samples per second (MSPS) and 500 MSPS digitizers. The zero crossing time markers (TM) were obtained with a standard digital constant fraction timing (DCF) method. Accurate timing information is obtained using cubic spline interpolation of a DCF transient region sample points. To get the best time-of-flight (TOF) resolution, an optimization of DCF parameters is performed (delay and constant fraction) for each pair of detectors: (BaF2-LaBr3), (BaF2-BC501A), and (LaBr3-BC501A). In addition, the slope information of an interpolated DCF signal is extracted at TM position. This information gives a new insight to understand the broadening in TOF, obtained for a given detector pair. For a pair of signals having small relative slope and interpolation deviations at TM, leads to minimum time broadening. However, the tailing in TOF spectra is dictated by the interplay between the interpolation error and slope variations. Best TOF resolution achieved at the optimum DCF parameters, can be further improved by using slope parameter. Guided by the relative slope parameter, events selection can be imposed which leads to reduction in TOF broadening. While the method sets a trade-off between timing response and coincidence efficiency, it provides an improvement in TOF. With the proposed method, the improved TOF resolution (FWHM) for the aforementioned detector pairs are; 25% (0.69 ns), 40% (0.74 ns), 53% (0.6 ns) respectively, obtained with 250 MSPS, and corresponds to 12% (0.37 ns), 33% (0.72 ns), 35% (0.69 ns) respectively with 500 MSPS digitizers. For the same detector pair, event survival probabilities are; 57%, 58%, 51% respectively with 250 MSPS and becomes 63%, 57%, 68% using 500 MSPS digitizers.
DigitalGlobe(TM) Incorporated Corporate and System Update
NASA Technical Reports Server (NTRS)
Thomassie, Brett
2007-01-01
This viewgraph presentation describes a system update of Quickbird, the world's highest resolution commercial imaging satellite, operated by DigitalGlobe (TM) Incorporated. A satellite comparison of Quickbird, WorldView-60, and WorldView-110 is also presented.
Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan
2016-03-07
The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems.In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm).Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution.
Cho, Sanghee; Grazioso, Ron; Zhang, Nan; Aykac, Mehmet; Schmand, Matthias
2011-12-07
The main focus of our study is to investigate how the performance of digital timing methods is affected by sampling rate, anti-aliasing and signal interpolation filters. We used the Nyquist sampling theorem to address some basic questions such as what will be the minimum sampling frequencies? How accurate will the signal interpolation be? How do we validate the timing measurements? The preferred sampling rate would be as low as possible, considering the high cost and power consumption of high-speed analog-to-digital converters. However, when the sampling rate is too low, due to the aliasing effect, some artifacts are produced in the timing resolution estimations; the shape of the timing profile is distorted and the FWHM values of the profile fluctuate as the source location changes. Anti-aliasing filters are required in this case to avoid the artifacts, but the timing is degraded as a result. When the sampling rate is marginally over the Nyquist rate, a proper signal interpolation is important. A sharp roll-off (higher order) filter is required to separate the baseband signal from its replicates to avoid the aliasing, but in return the computation will be higher. We demonstrated the analysis through a digital timing study using fast LSO scintillation crystals as used in time-of-flight PET scanners. From the study, we observed that there is no significant timing resolution degradation down to 1.3 Ghz sampling frequency, and the computation requirement for the signal interpolation is reasonably low. A so-called sliding test is proposed as a validation tool checking constant timing resolution behavior of a given timing pick-off method regardless of the source location change. Lastly, the performance comparison for several digital timing methods is also shown.
NASA Astrophysics Data System (ADS)
Tanguay, Jesse; Benard, Francois; Celler, Anna; Ruth, Thomas; Schaffer, Paul
2017-03-01
Attaching alpha-emitting radionuclides to cancer-targeting agents increases the anti-tumor effects of targeted cancer therapies. The success of alpha therapy for treating bone metastases has increased interest in using targeted alpha therapy (TAT) to treat a broad spectrum of metastatic cancers. Estimating radiation doses to targeted tumors, including small (<250 μm) clusters of cancer cells, and to non-targeted tissues is critical in the pre-clinical development of TATs. However, accurate quantification of heterogeneous distributions of alpha-emitters in small metastases is not possible with existing pre-clinical in-vivo imaging systems. Ex-vivo digital autoradiography using a scintillator in combination with an image intensifier and a charged coupled device (CCD) has gained interest for pre-clinical ex-vivo alpha particle imaging. We present a simulation-based analysis of the fundamental spatial resolution limits of digital autoradiography systems. Spatial resolution was quantified in terms of the modulation transfer function (MTF) and Wagner's equivalent aperture. We modeled systems operating in either particle-counting (PC) or energy-integrating (EI) mode using a cascaded systems approach that accounts for: 1) the stopping power of alpha particles; 2) the distance alpha particles travel within the scintillator; 3) optical blur, and; 4) binning in detector elements. We applied our analysis to imaging of astatine-211 using an LYSO scintillator with thickness ranging from 10 μm to 20 μm. Our analysis demonstrates that when these systems are operated in particle-counting mode with a centroid-calculation algorithm, the effective apertures of 35 μm can be achieved, which suggests that digital autoradiography may enable quantifying the uptake of alpha emitters in tumors consisting of a few cancer cells. Future work will investigate the image noise and energy-resolution properties of digital autoradiography systems.
Wacker, Irene U.; Veith, Lisa; Spomer, Waldemar; Hofmann, Andreas; Thaler, Marlene; Hillmer, Stefan; Gengenbach, Ulrich; Schröder, Rasmus R.
2018-01-01
Targeting specific cells at ultrastructural resolution within a mixed cell population or a tissue can be achieved by hierarchical imaging using a combination of light and electron microscopy. Samples embedded in resin are sectioned into arrays consisting of ribbons of hundreds of ultrathin sections and deposited on pieces of silicon wafer or conductively coated coverslips. Arrays are imaged at low resolution using a digital consumer like smartphone camera or light microscope (LM) for a rapid large area overview, or a wide field fluorescence microscope (fluorescence light microscopy (FLM)) after labeling with fluorophores. After post-staining with heavy metals, arrays are imaged in a scanning electron microscope (SEM). Selection of targets is possible from 3D reconstructions generated by FLM or from 3D reconstructions made from the SEM image stacks at intermediate resolution if no fluorescent markers are available. For ultrastructural analysis, selected targets are finally recorded in the SEM at high-resolution (a few nanometer image pixels). A ribbon-handling tool that can be retrofitted to any ultramicrotome is demonstrated. It helps with array production and substrate removal from the sectioning knife boat. A software platform that allows automated imaging of arrays in the SEM is discussed. Compared to other methods generating large volume EM data, such as serial block-face SEM (SBF-SEM) or focused ion beam SEM (FIB-SEM), this approach has two major advantages: (1) The resin-embedded sample is conserved, albeit in a sliced-up version. It can be stained in different ways and imaged with different resolutions. (2) As the sections can be post-stained, it is not necessary to use samples strongly block-stained with heavy metals to introduce contrast for SEM imaging or render the tissue blocks conductive. This makes the method applicable to a wide variety of materials and biological questions. Particularly prefixed materials e.g., from biopsy banks and pathology labs, can directly be embedded and reconstructed in 3D. PMID:29630046
Sharable Courseware Object Reference Model (SCORM), Version 1.0
2000-07-01
or query tool may provide the top- level entries of a well-established classification (LOC, UDC, DDC , and so forth). SEL 9.2.2 Taxon This subcategory...YYYY/MM/DD. CMIFeedback Structured description of student response in an interaction. CMIDecimal Number which may have a decimal point. If not...Seconds shall contain 2 digits with an optional decimal point and additional digits. CMITimespan A length of time in hours, minutes, and seconds
Steering of Upper Ocean Currents and Fronts by the Topographically Constrained Abyssal Circulation
2008-07-06
a) Mean surface dynamic height relative to 1000 m from version 2.5 of the Generalized Digital Environmental Model ( GDEM ) oceanic climatology, an...NLOM simulations in comparison to the mean surface dynamic height with respect to 1000 m from the Generalized Digital Environmental Model ( GDEM ...the Kuroshio pathway east of Japan, giving much better agreement with the pathway in the GDEM climatology. Dynamics of the topographic impact on
Analysis of Ultra High Resolution Sea Surface Temperature Level 4 Datasets
NASA Technical Reports Server (NTRS)
Wagner, Grant
2011-01-01
Sea surface temperature (SST) studies are often focused on improving accuracy, or understanding and quantifying uncertainties in the measurement, as SST is a leading indicator of climate change and represents the longest time series of any ocean variable observed from space. Over the past several decades SST has been studied with the use of satellite data. This allows a larger area to be studied with much more frequent measurements being taken than direct measurements collected aboard ship or buoys. The Group for High Resolution Sea Surface Temperature (GHRSST) is an international project that distributes satellite derived sea surface temperatures (SST) data from multiple platforms and sensors. The goal of the project is to distribute these SSTs for operational uses such as ocean model assimilation and decision support applications, as well as support fundamental SST research and climate studies. Examples of near real time applications include hurricane and fisheries studies and numerical weather forecasting. The JPL group has produced a new 1 km daily global Level 4 SST product, the Multiscale Ultrahigh Resolution (MUR), that blends SST data from 3 distinct NASA radiometers: the Moderate Resolution Imaging Spectroradiometer (MODIS), the Advanced Very High Resolution Radiometer (AVHRR), and the Advanced Microwave Scanning Radiometer ? Earth Observing System(AMSRE). This new product requires further validation and accuracy assessment, especially in coastal regions.We examined the accuracy of the new MUR SST product by comparing the high resolution version and a lower resolution version that has been smoothed to 19 km (but still gridded to 1 km). Both versions were compared to the same data set of in situ buoy temperature measurements with a focus on study regions of the oceans surrounding North and Central America as well as two smaller regions around the Gulf Stream and California coast. Ocean fronts exhibit high temperature gradients (Roden, 1976), and thus satellite data of SST can be used in the detection of these fronts. In this case, accuracy is less of a concern because the primary focus is on the spatial derivative of SST. We calculated the gradients for both versions of the MUR data set and did statistical comparisons focusing on the same regions.
Fidler, Samantha; D'Orsogna, Lloyd; Irish, Ashley B; Lewis, Joshua R; Wong, Germaine; Lim, Wai H
2018-03-02
Structural human leukocyte antigen (HLA) matching at the eplet level can be identified by HLAMatchmaker, which requires the entry of four-digit alleles. The aim of this study was to evaluate the agreement between eplet mismatches calculated by serological and two-digit typing methods compared to high-resolution four-digit typing. In a cohort of 264 donor/recipient pairs, the evaluation of measurement error was assessed using intra-class correlation to confirm the absolute agreement between the number of eplet mismatches at class I (HLA-A, -B, C) and II loci (HLA-DQ and -DR) calculated using serological or two-digit molecular typing compared to four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches between the HLA typing methods was also determined. Intra-class correlation coefficients between serological and four-digit molecular typing methods were 0.969 (95% confidence intervals [95% CI] 0.960-0.975) and 0.926 (95% CI 0.899-0.944), respectively; and 0.995 (95% CI 0.994-0.996) and 0.993 (95% CI 0.991-0.995), respectively between two-digit and four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches at class I and II loci was 4% and 16% for serological versus four-digit molecular typing methods, and 0% and 2% for two-digit versus four-digit molecular typing methods, respectively. In this small predominantly Caucasian population, compared with serology, there is a high level of agreement in the number of eplet mismatches calculated using two-compared to four-digit molecular HLA-typing methods, suggesting that two-digit typing may be sufficient in determining eplet mismatch load in kidney transplantation.
2007-09-27
the spatial and spectral resolution ...variety of geological and vegetation mapping efforts, the Hymap sensor offered the best available combination of spectral and spatial resolution , signal... The limitations of the technology currently relate to spatial and spectral resolution and geo- correction accuracy. Secondly, HSI datasets
Applications of a digital darkroom in the forensic laboratory
NASA Astrophysics Data System (ADS)
Bullard, Barry D.; Birge, Brian
1997-02-01
Through a joint agreement with the Indiana-Marion County Forensic Laboratory Services Agency, the Institute for Forensic Imaging conducted a pilot program to investigate crime lab applications of a digital darkroom. IFI installed and staffed a state-of-the-art digital darkroom in the photography laboratory of the Indianapolis-Marion County crime lab located at Indianapolis, Indiana. The darkroom consisted of several high resolution color digital cameras, image processing computer, dye sublimation continuous tone digital printers, and CD-ROM writer. This paper describes the use of the digital darkroom in several crime lab investigations conducted during the program.
NASA Astrophysics Data System (ADS)
Muller, J.-P.; Yershov, V.; Sidiropoulos, P.; Gwinner, K.; Willner, K.; Fanara, L.; Waelisch, M.; van Gasselt, S.; Walter, S.; Ivanov, A.; Cantini, F.; Morley, J. G.; Sprinks, J.; Giordano, M.; Wardlaw, J.; Kim, J.-R.; Chen, W.-T.; Houghton, R.; Bamford, S.
2015-10-01
Understanding the role of different solid surface formation processes within our Solar System is one of the fundamental goals of planetary science research. There has been a revolution in planetary surface observations over the last 8 years, especially in 3D imaging of surface shape (down to resolutions of 10s of cms) and subsequent terrain correction of imagery from orbiting spacecraft. This has led to the potential to be able to overlay different epochs back to the mid-1970s. Within iMars, a processing system has been developed to generate 3D Digital Terrain Models (DTMs) and corresponding OrthoRectified Images (ORIs) fully automatically from NASA MRO HiRISE and CTX stereo-pairs which are coregistered to corresponding HRSC ORI/DTMs. In parallel, iMars has developed a fully automated processing chain for co-registering level-1 (EDR) images from all previous NASA orbital missions to these HRSC ORIs and in the case of HiRISE these are further co-registered to previously co-registered CTX-to-HRSC ORIs. Examples will be shown of these multi-resolution ORIs and the application of different data mining algorithms to change detection using these co-registered images. iMars has recently launched a citizen science experiment to evaluate best practices for future citizen scientist validation of such data mining processed results. An example of the iMars website will be shown along with an embedded Version 0 prototype of a webGIS based on OGC standards.
The laboratory demonstration and signal processing of the inverse synthetic aperture imaging ladar
NASA Astrophysics Data System (ADS)
Gao, Si; Zhang, ZengHui; Xu, XianWen; Yu, WenXian
2017-10-01
This paper presents a coherent inverse synthetic-aperture imaging ladar(ISAL)system to obtain high resolution images. A balanced coherent optics system in laboratory is built with binary phase coded modulation transmit waveform which is different from conventional chirp. A whole digital signal processing solution is proposed including both quality phase gradient autofocus(QPGA) algorithm and cubic phase function(CPF) algorithm. Some high-resolution well-focused ISAL images of retro-reflecting targets are shown to validate the concepts. It is shown that high resolution images can be achieved and the influences from vibrations of platform involving targets and radar can be automatically compensated by the distinctive laboratory system and digital signal process.
Simultaneous digital super-resolution and nonuniformity correction for infrared imaging systems.
Meza, Pablo; Machuca, Guillermo; Torres, Sergio; Martin, Cesar San; Vera, Esteban
2015-07-20
In this article, we present a novel algorithm to achieve simultaneous digital super-resolution and nonuniformity correction from a sequence of infrared images. We propose to use spatial regularization terms that exploit nonlocal means and the absence of spatial correlation between the scene and the nonuniformity noise sources. We derive an iterative optimization algorithm based on a gradient descent minimization strategy. Results from infrared image sequences corrupted with simulated and real fixed-pattern noise show a competitive performance compared with state-of-the-art methods. A qualitative analysis on the experimental results obtained with images from a variety of infrared cameras indicates that the proposed method provides super-resolution images with significantly less fixed-pattern noise.
Measurement Sets and Sites Commonly Used for High Spatial Resolution Image Product Characterization
NASA Technical Reports Server (NTRS)
Pagnutti, Mary
2006-01-01
Scientists within NASA's Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site has enabled the in-flight characterization of satellite high spatial resolution remote sensing system products form Space Imaging IKONOS, Digital Globe QuickBird, and ORBIMAGE OrbView, as well as advanced multispectral airborne digital camera products. SSC utilizes engineered geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment and their Instrument Validation Laboratory to characterize high spatial resolution remote sensing data products. This presentation describes the SSC characterization capabilities and techniques in the visible through near infrared spectrum and examples of calibration results.
Development of a Digital Microarray with Interferometric Reflectance Imaging
NASA Astrophysics Data System (ADS)
Sevenler, Derin
This dissertation describes a new type of molecular assay for nucleic acids and proteins. We call this technique a digital microarray since it is conceptually similar to conventional fluorescence microarrays, yet it performs enumerative ('digital') counting of the number captured molecules. Digital microarrays are approximately 10,000-fold more sensitive than fluorescence microarrays, yet maintain all of the strengths of the platform including low cost and high multiplexing (i.e., many different tests on the same sample simultaneously). Digital microarrays use gold nanorods to label the captured target molecules. Each gold nanorod on the array is individually detected based on its light scattering, with an interferometric microscopy technique called SP-IRIS. Our optimized high-throughput version of SP-IRIS is able to scan a typical array of 500 spots in less than 10 minutes. Digital DNA microarrays may have utility in applications where sequencing is prohibitively expensive or slow. As an example, we describe a digital microarray assay for gene expression markers of bacterial drug resistance.
NASA Astrophysics Data System (ADS)
Gui, Jianbao; Guo, Jinchuan; Yang, Qinlao; Liu, Xin; Niu, Hanben
2007-05-01
X-ray phase contrast imaging is a promising new technology today, but the requirements of a digital detector with large area, high spatial resolution and high sensitivity bring forward a large challenge to researchers. This paper is related to the design and theoretical investigation of an x-ray direct conversion digital detector based on mercuric iodide photoconductive layer with the latent charge image readout by photoinduced discharge (PID). Mercuric iodide has been verified having a good imaging performance (high sensitivity, low dark current, low voltage operation and good lag characteristics) compared with the other competitive materials (α-Se,PbI II,CdTe,CdZnTe) and can be easily deposited on large substrates in the manner of polycrystalline. By use of line scanning laser beam and parallel multi-electrode readout make the system have high spatial resolution and fast readout speed suitable for instant general radiography and even rapid sequence radiography.
NASA Astrophysics Data System (ADS)
Chi, Yuxi; Yu, Liping; Pan, Bing
2018-05-01
A low-cost, portable, robust and high-resolution single-camera stereo-digital image correlation (stereo-DIC) system for accurate surface three-dimensional (3D) shape and deformation measurements is described. This system adopts a single consumer-grade high-resolution digital Single Lens Reflex (SLR) camera and a four-mirror adaptor, rather than two synchronized industrial digital cameras, for stereo image acquisition. In addition, monochromatic blue light illumination and coupled bandpass filter imaging are integrated to ensure the robustness of the system against ambient light variations. In contrast to conventional binocular stereo-DIC systems, the developed pseudo-stereo-DIC system offers the advantages of low cost, portability, robustness against ambient light variations, and high resolution. The accuracy and precision of the developed single SLR camera-based stereo-DIC system were validated by measuring the 3D shape of a stationary sphere along with in-plane and out-of-plane displacements of a translated planar plate. Application of the established system to thermal deformation measurement of an alumina ceramic plate and a stainless-steel plate subjected to radiation heating was also demonstrated.
A flexible, open, decentralized system for digital pathology networks.
Schuler, Robert; Smith, David E; Kumaraguruparan, Gowri; Chervenak, Ann; Lewis, Anne D; Hyde, Dallas M; Kesselman, Carl
2012-01-01
High-resolution digital imaging is enabling digital archiving and sharing of digitized microscopy slides and new methods for digital pathology. Collaborative research centers, outsourced medical services, and multi-site organizations stand to benefit from sharing pathology data in a digital pathology network. Yet significant technological challenges remain due to the large size and volume of digitized whole slide images. While information systems do exist for managing local pathology laboratories, they tend to be oriented toward narrow clinical use cases or offer closed ecosystems around proprietary formats. Few solutions exist for networking digital pathology operations. Here we present a system architecture and implementation of a digital pathology network and share results from a production system that federates major research centers.
A Flexible, Open, Decentralized System for Digital Pathology Networks
SMITH, David E.; KUMARAGURUPARAN, Gowri; CHERVENAK, Ann; LEWIS, Anne D.; HYDE, Dallas M.; KESSELMAN, Carl
2014-01-01
High-resolution digital imaging is enabling digital archiving and sharing of digitized microscopy slides and new methods for digital pathology. Collaborative research centers, outsourced medical services, and multi-site organizations stand to benefit from sharing pathology data in a digital pathology network. Yet significant technological challenges remain due to the large size and volume of digitized whole slide images. While information systems do exist for managing local pathology laboratories, they tend to be oriented toward narrow clinical use cases or offer closed ecosystems around proprietary formats. Few solutions exist for networking digital pathology operations. Here we present a system architecture and implementation of a digital pathology network and share results from a production system that federates major research centers. PMID:22941985
The digital geologic map of Colorado in ARC/INFO format, Part A. Documentation
Green, Gregory N.
1992-01-01
This geologic map was prepared as a part of a study of digital methods and techniques as applied to complex geologic maps. The geologic map was digitized from the original scribe sheets used to prepare the published Geologic Map of Colorado (Tweto 1979). Consequently the digital version is at 1:500,000 scale using the Lambert Conformal Conic map projection parameters of the state base map. Stable base contact prints of the scribe sheets were scanned on a Tektronix 4991 digital scanner. The scanner automatically converts the scanned image to an ASCII vector format. These vectors were transferred to a VAX minicomputer, where they were then loaded into ARC/INFO. Each vector and polygon was given attributes derived from the original 1979 geologic map. This database was developed on a MicroVAX computer system using VAX V 5.4 nd ARC/INFO 5.0 software. UPDATE: April 1995, The update was done solely for the purpose of adding the abilitly to plot to an HP650c plotter. Two new ARC/INFO plot AMLs along with a lineset and shadeset for the HP650C design jet printer have been included. These new files are COLORADO.650, INDEX.650, TWETOLIN.E00 and TWETOSHD.E00. These files were created on a UNIX platform with ARC/INFO 6.1.2. Updated versions of INDEX.E00, CONTACT.E00, LINE.E00, DECO.E00 and BORDER.E00 files that included the newly defined HP650c items are also included. * Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Descriptors: The Digital Geologic Map of Colorado in ARC/INFO Format Open-File Report 92-050
The digital geologic map of Colorado in ARC/INFO format, Part B. Common files
Green, Gregory N.
1992-01-01
This geologic map was prepared as a part of a study of digital methods and techniques as applied to complex geologic maps. The geologic map was digitized from the original scribe sheets used to prepare the published Geologic Map of Colorado (Tweto 1979). Consequently the digital version is at 1:500,000 scale using the Lambert Conformal Conic map projection parameters of the state base map. Stable base contact prints of the scribe sheets were scanned on a Tektronix 4991 digital scanner. The scanner automatically converts the scanned image to an ASCII vector format. These vectors were transferred to a VAX minicomputer, where they were then loaded into ARC/INFO. Each vector and polygon was given attributes derived from the original 1979 geologic map. This database was developed on a MicroVAX computer system using VAX V 5.4 nd ARC/INFO 5.0 software. UPDATE: April 1995, The update was done solely for the purpose of adding the abilitly to plot to an HP650c plotter. Two new ARC/INFO plot AMLs along with a lineset and shadeset for the HP650C design jet printer have been included. These new files are COLORADO.650, INDEX.650, TWETOLIN.E00 and TWETOSHD.E00. These files were created on a UNIX platform with ARC/INFO 6.1.2. Updated versions of INDEX.E00, CONTACT.E00, LINE.E00, DECO.E00 and BORDER.E00 files that included the newly defined HP650c items are also included. * Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Descriptors: The Digital Geologic Map of Colorado in ARC/INFO Format Open-File Report 92-050
Cheng, Li-Chung; Lien, Chi-Hsiang; Da Sie, Yong; Hu, Yvonne Yuling; Lin, Chun-Yu; Chien, Fan-Ching; Xu, Chris; Dong, Chen Yuan; Chen, Shean-Jen
2014-08-01
In this study, the light diffraction of temporal focusing multiphoton excitation microscopy (TFMPEM) and the excitation patterning of nonlinear structured-illumination microscopy (NSIM) can be simultaneously and accurately implemented via a single high-resolution digital micromirror device. The lateral and axial spatial resolutions of the TFMPEM are remarkably improved through the second-order NSIM and projected structured light, respectively. The experimental results demonstrate that the lateral and axial resolutions are enhanced from 397 nm to 168 nm (2.4-fold) and from 2.33 μm to 1.22 μm (1.9-fold), respectively, in full width at the half maximum. Furthermore, a three-dimensionally rendered image of a cytoskeleton cell featuring ~25 nm microtubules is improved, with other microtubules at a distance near the lateral resolution of 168 nm also able to be distinguished.
Low-Light Image Enhancement Using Adaptive Digital Pixel Binning
Yoo, Yoonjong; Im, Jaehyun; Paik, Joonki
2015-01-01
This paper presents an image enhancement algorithm for low-light scenes in an environment with insufficient illumination. Simple amplification of intensity exhibits various undesired artifacts: noise amplification, intensity saturation, and loss of resolution. In order to enhance low-light images without undesired artifacts, a novel digital binning algorithm is proposed that considers brightness, context, noise level, and anti-saturation of a local region in the image. The proposed algorithm does not require any modification of the image sensor or additional frame-memory; it needs only two line-memories in the image signal processor (ISP). Since the proposed algorithm does not use an iterative computation, it can be easily embedded in an existing digital camera ISP pipeline containing a high-resolution image sensor. PMID:26121609
A Digital Preclinical PET/MRI Insert and Initial Results.
Weissler, Bjoern; Gebhardt, Pierre; Dueppenbecker, Peter M; Wehner, Jakob; Schug, David; Lerche, Christoph W; Goldschmidt, Benjamin; Salomon, Andre; Verel, Iris; Heijman, Edwin; Perkuhn, Michael; Heberling, Dirk; Botnar, Rene M; Kiessling, Fabian; Schulz, Volkmar
2015-11-01
Combining Positron Emission Tomography (PET) with Magnetic Resonance Imaging (MRI) results in a promising hybrid molecular imaging modality as it unifies the high sensitivity of PET for molecular and cellular processes with the functional and anatomical information from MRI. Digital Silicon Photomultipliers (dSiPMs) are the digital evolution in scintillation light detector technology and promise high PET SNR. DSiPMs from Philips Digital Photon Counting (PDPC) were used to develop a preclinical PET/RF gantry with 1-mm scintillation crystal pitch as an insert for clinical MRI scanners. With three exchangeable RF coils, the hybrid field of view has a maximum size of 160 mm × 96.6 mm (transaxial × axial). 0.1 ppm volume-root-mean-square B 0-homogeneity is kept within a spherical diameter of 96 mm (automatic volume shimming). Depending on the coil, MRI SNR is decreased by 13% or 5% by the PET system. PET count rates, energy resolution of 12.6% FWHM, and spatial resolution of 0.73 mm (3) (isometric volume resolution at isocenter) are not affected by applied MRI sequences. PET time resolution of 565 ps (FWHM) degraded by 6 ps during an EPI sequence. Timing-optimized settings yielded 260 ps time resolution. PET and MR images of a hot-rod phantom show no visible differences when the other modality was in operation and both resolve 0.8-mm rods. Versatility of the insert is shown by successfully combining multi-nuclei MRI ((1)H/(19)F) with simultaneously measured PET ((18)F-FDG). A longitudinal study of a tumor-bearing mouse verifies the operability, stability, and in vivo capabilities of the system. Cardiac- and respiratory-gated PET/MRI motion-capturing (CINE) images of the mouse heart demonstrate the advantage of simultaneous acquisition for temporal and spatial image registration.
The Mars Climate Database (MCD version 5.2)
NASA Astrophysics Data System (ADS)
Millour, E.; Forget, F.; Spiga, A.; Navarro, T.; Madeleine, J.-B.; Montabone, L.; Pottier, A.; Lefevre, F.; Montmessin, F.; Chaufray, J.-Y.; Lopez-Valverde, M. A.; Gonzalez-Galindo, F.; Lewis, S. R.; Read, P. L.; Huot, J.-P.; Desjean, M.-C.; MCD/GCM development Team
2015-10-01
The Mars Climate Database (MCD) is a database of meteorological fields derived from General Circulation Model (GCM) numerical simulations of the Martian atmosphere and validated using available observational data. The MCD includes complementary post-processing schemes such as high spatial resolution interpolation of environmental data and means of reconstructing the variability thereof. We have just completed (March 2015) the generation of a new version of the MCD, MCD version 5.2
A low jitter all - digital phase - locked loop in 180 nm CMOS technology
NASA Astrophysics Data System (ADS)
Shumkin, O. V.; Butuzov, V. A.; Normanov, D. D.; Ivanov, P. Yu
2016-02-01
An all-digital phase locked loop (ADPLL) was implemented in 180 nm CMOS technology. The proposed ADPLL uses a digitally controlled oscillator to achieve 3 ps resolution. The pure digital phase locked loop is attractive because it is less sensitive to noise and operating conditions than its analog counterpart. The proposed ADPLL can be easily applied to different process as a soft IP block, making it very suitable for system-on-chip applications.
Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics
NASA Technical Reports Server (NTRS)
Bandler, S. R.; Adams, J. S.; Bailey, C. N.; Busch, S. E.; Chervenak, J. A.; Eckart, M. E.; Ewin, A. E.; Finkbeiner, F. M.; Kelley, R. L.; Kelly, D. P.;
2012-01-01
We are developing small-pixel transition-edge-sensor (TES) for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to accommodate count-rates of up to a few hundred counts/pixel/second at a FWHM energy resolution approximately 2 eV at 6 keV. We have fabricated versions that utilize narrow-line planar and stripline wiring. We present measurements of the performance and uniformity of kilo-pixel arrays, incorporating TESs with single 65-micron absorbers on a 7s-micron pitch, as well as versions with more than one absorber attached to the TES, 4-absorber and 9-absorber "Hydras". We have also fabricated a version of this detector optimized for lower energies and lower count-rate applications. These devices have a lower superconducting transition temperature and are operated just above the 40mK heat sink temperature. This results in a lower heat capacity and low thermal conductance to the heat sink. With individual single pixels of this type we have achieved a FWHM energy resolution of 0.9 eV with 1.5 keV Al K x-rays, to our knowledge the first x-ray microcalorimeter with sub-eV energy resolution. The 4-absorber and 9-absorber versions of this type achieved FWHM energy resolutions of 1.4 eV and 2.1 eV at 1.5 keV respectively. We will discuss the application of these devices for new astrophysics mission concepts.
Explain the CERES file naming convention
Atmospheric Science Data Center
2014-12-08
... using the dataset name, configuration code and date information which make each file name unique. A Dataset name consists ...
A parallel unbalanced digitization architecture to reduce the dynamic range of multiple signals
NASA Astrophysics Data System (ADS)
Vallérian, Mathieu; HuÅ£u, Florin; Villemaud, Guillaume; Miscopein, Benoît; Risset, Tanguy
2016-05-01
Technologies employed in urban sensor networks are permanently evolving, and thus the gateways employed to collect data in such kind of networks have to be very flexible in order to be compliant with the new communication standards. A convenient way to do that is to digitize all the received signals in one shot and then to digitally perform the signal processing, as it is done in software-defined radio (SDR). All signals can be emitted with very different features (bandwidth, modulation type, and power level) in order to respond to the various propagation conditions. Their difference in terms of power levels is a problem when digitizing them together, as no current commercial analog-to-digital converter (ADC) can provide a fine enough resolution to digitize this high dynamic range between the weakest possible signal in the presence of a stronger signal. This paper presents an RF front end receiver architecture capable of handling this problem by using two ADCs of lower resolutions. The architecture is validated through a set of simulations using Keysight's ADS software. The main validation criterion is the bit error rate comparison with a classical receiver.
The Effect of Remote Sensor Spatial Resolution in Monitoring U.S. Army Training Maneuver Sites
1990-12-01
THE EFFECT OF REMOTE SENSOR SPATIAL RESOLUTION IN MONITORING U.S. ARMY...Multispectral Scanner with 6.5 meter spatial resolution provided the most effective digital data set for enhancing tank trails. However, this Airborne Scanner...primary objective of this research was to determine the capabilities and limitations of remote sensor systems having different spatial resolutions to
Clauson, Kevin A; Polen, Hyla H; Marsh, Wallace A
2007-12-01
To evaluate personal digital assistant (PDA) drug information databases used to support clinical decision-making, and to compare the performance of PDA databases with their online versions. Prospective evaluation with descriptive analysis. Five drug information databases available for PDAs and online were evaluated according to their scope (inclusion of correct answers), completeness (on a 3-point scale), and ease of use; 158 question-answer pairs across 15 weighted categories of drug information essential to health care professionals were used to evaluate these databases. An overall composite score integrating these three measures was then calculated. Scores for the PDA databases and for each PDA-online pair were compared. Among the PDA databases, composite rankings, from highest to lowest, were as follows: Lexi-Drugs, Clinical Pharmacology OnHand, Epocrates Rx Pro, mobileMicromedex (now called Thomson Clinical Xpert), and Epocrates Rx free version. When we compared database pairs, online databases that had greater scope than their PDA counterparts were Clinical Pharmacology (137 vs 100 answers, p<0.001), Micromedex (132 vs 96 answers, p<0.001), Lexi-Comp Online (131 vs 119 answers, p<0.001), and Epocrates Online Premium (103 vs 98 answers, p=0.001). Only Micromedex online was more complete than its PDA version (p=0.008). Regarding ease of use, the Lexi-Drugs PDA database was superior to Lexi-Comp Online (p<0.001); however, Epocrates Online Premium, Epocrates Online Free, and Micromedex online were easier to use than their PDA counterparts (p<0.001). In terms of composite scores, only the online versions of Clinical Pharmacology and Micromedex demonstrated superiority over their PDA versions (p>0.01). Online and PDA drug information databases assist practitioners in improving their clinical decision-making. Lexi-Drugs performed significantly better than all of the other PDA databases evaluated. No PDA database demonstrated superiority to its online counterpart; however, the online versions of Clinical Pharmacology and Micromedex were superior to their PDA versions in answering questions.
Digital geologic map of the Coeur d'Alene 1:100,000 quadrangle, Idaho and Montana
digital compilation by Munts, Steven R.
2000-01-01
Between 1961 and 1969, Alan Griggs and others conducted fieldwork to prepare a geologic map of the Spokane 1:250,000 map (Griggs, 1973). Their field observations were posted on paper copies of 15-minute quadrangle maps. In 1999, the USGS contracted with the Idaho Geological Survey to prepare a digital version of the Coeur d’Alene 1:100,000 quadrangle. To facilitate this work, the USGS obtained the field maps prepared by Griggs and others from the USGS Field Records Library in Denver, Colorado. The Idaho Geological Survey (IGS) digitized these maps and used them in their mapping program. The mapping focused on field checks to resolve problems in poorly known areas and in areas of disagreement between adjoining maps. The IGS is currently in the process of preparing a final digital spatial database for the Coeur d’Alene 1:100,000 quadrangle. However, there was immediate need for a digital version of the geologic map of the Coeur d’Alene 1:100,000 quadrangle and the data from the field sheets along with several other sources were assembled to produce this interim product. This interim product is the digital geologic map of the Coeur d’Alene 1:100,000 quadrangle, Idaho and Montana. It was compiled from the preliminary digital files prepared by the Idaho Geological, and supplemented by data from Griggs (1973) and from digital databases by Bookstrom and others (1999) and Derkey and others (1996). The resulting digital geologic map (GIS) database can be queried in many ways to produce a variety of geologic maps. Digital base map data files (topography, roads, towns, rivers and lakes, etc.) are not included: they may be obtained from a variety of commercial and government sources. This database is not meant to be used or displayed at any scale larger than 1:100,000 (e.g., 1:62,500 or 1:24,000). The digital geologic map graphics (of00-135_map.pdf) that are provided are representations of the digital database. The map area is located in north Idaho. This open-file report describes the geologic map units, the methods used to convert the geologic map data into a digital format, the ArcInfo GIS file structures and relationships, and explains how to download the digital files from the U.S. Geological Survey public access World Wide Web site on the Internet.
Installing the Unix Starlink Software
NASA Astrophysics Data System (ADS)
Bly, M. J.
This note is the release note and installation instructions for the DEC Alpha AXP / Digital UNIX, Sun Sparc / Solaris v2.x, and Sun Sparc / SunOS 4.1.x versions of the Starlink Software Collection (USSC). You will be supplied with pre-built (and installed) versions on tape and will just need to copy the tape to disk to have a working version. The tapes (where appropriate) will contain in addition, copies of the NAG and MEMSYS libraries, and Tcl, Tk, Expect, Mosaic, TeX, Pine, Perl, Jed, Ispell, Ghostscript, LaXeX2html and Ftnchek for the relevant system. The Sun Sparc SunOS 4.1.x version of the USSC was frozen at USSC111 and no further updates are available. The instructions for installing the main section of the USSC may continue to be used for installing Sun Sparc SunOS 4.1.x version.
Earth observation data based rapid flood-extent modelling for tsunami-devastated coastal areas
NASA Astrophysics Data System (ADS)
Hese, Sören; Heyer, Thomas
2016-04-01
Earth observation (EO)-based mapping and analysis of natural hazards plays a critical role in various aspects of post-disaster aid management. Spatial very high-resolution Earth observation data provide important information for managing post-tsunami activities on devastated land and monitoring re-cultivation and reconstruction. The automatic and fast use of high-resolution EO data for rapid mapping is, however, complicated by high spectral variability in densely populated urban areas and unpredictable textural and spectral land-surface changes. The present paper presents the results of the SENDAI project, which developed an automatic post-tsunami flood-extent modelling concept using RapidEye multispectral satellite data and ASTER Global Digital Elevation Model Version 2 (GDEM V2) data of the eastern coast of Japan (captured after the Tohoku earthquake). In this paper, the authors developed both a bathtub-modelling approach and a cost-distance approach, and integrated the roughness parameters of different land-use types to increase the accuracy of flood-extent modelling. Overall, the accuracy of the developed models reached 87-92%, depending on the analysed test site. The flood-modelling approach was explained and results were compared with published approaches. We came to the conclusion that the cost-factor-based approach reaches accuracy comparable to published results from hydrological modelling. However the proposed cost-factor approach is based on a much simpler dataset, which is available globally.
Smith, J. LaRue; Damar, Nancy A.; Charlet, David A.; Westenburg, Craig L.
2014-01-01
DigitalGlobe’s QuickBird satellite high-resolution multispectral imagery was classified by using Visual Learning Systems’ Feature Analyst feature extraction software to produce land-cover data sets for the Red Rock Canyon National Conservation Area and the Coyote Springs, Piute-Eldorado Valley, and Mormon Mesa Areas of Critical Environmental Concern in Clark County, Nevada. Over 1,000 vegetation field samples were collected at the stand level. The field samples were classified to the National Vegetation Classification Standard, Version 2 hierarchy at the alliance level and above. Feature extraction models were developed for vegetation on the basis of the spectral and spatial characteristics of selected field samples by using the Feature Analyst hierarchical learning process. Individual model results were merged to create one data set for the Red Rock Canyon National Conservation Area and one for each of the Areas of Critical Environmental Concern. Field sample points and photographs were used to validate and update the data set after model results were merged. Non-vegetation data layers, such as roads and disturbed areas, were delineated from the imagery and added to the final data sets. The resulting land-cover data sets are significantly more detailed than previously were available, both in resolution and in vegetation classes.
Cost-estimating for commercial digital printing
NASA Astrophysics Data System (ADS)
Keif, Malcolm G.
2007-01-01
The purpose of this study is to document current cost-estimating practices used in commercial digital printing. A research study was conducted to determine the use of cost-estimating in commercial digital printing companies. This study answers the questions: 1) What methods are currently being used to estimate digital printing? 2) What is the relationship between estimating and pricing digital printing? 3) To what extent, if at all, do digital printers use full-absorption, all-inclusive hourly rates for estimating? Three different digital printing models were identified: 1) Traditional print providers, who supplement their offset presswork with digital printing for short-run color and versioned commercial print; 2) "Low-touch" print providers, who leverage the power of the Internet to streamline business transactions with digital storefronts; 3) Marketing solutions providers, who see printing less as a discrete manufacturing process and more as a component of a complete marketing campaign. Each model approaches estimating differently. Understanding and predicting costs can be extremely beneficial. Establishing a reliable system to estimate those costs can be somewhat challenging though. Unquestionably, cost-estimating digital printing will increase in relevance in the years ahead, as margins tighten and cost knowledge becomes increasingly more critical.
A randomized trial comparing digital and live lecture formats [ISRCTN40455708.
Solomon, David J; Ferenchick, Gary S; Laird-Fick, Heather S; Kavanaugh, Kevin
2004-11-29
Medical education is increasingly being conducted in community-based teaching sites at diverse locations, making it difficult to provide a consistent curriculum. We conducted a randomized trial to assess whether students who viewed digital lectures would perform as well on a measure of cognitive knowledge as students who viewed live lectures. Students' perceptions of the digital lecture format and their opinion as whether a digital lecture format could serve as an adequate replacement for live lectures was also assessed. Students were randomized to either attend a lecture series at our main campus or view digital versions of the same lectures at community-based teaching sites. Both groups completed the same examination based on the lectures, and the group viewing the digital lectures completed a feedback form on the digital format. There were no differences in performance as measured by means or average rank. Despite technical problems, the students who viewed the digital lectures overwhelmingly felt the digital lectures could replace live lectures. This study provides preliminary evidence digital lectures can be a viable alternative to live lectures as a means of delivering didactic presentations in a community-based setting.
A randomized trial comparing digital and live lecture formats [ISRCTN40455708
Solomon, David J; Ferenchick, Gary S; Laird-Fick, Heather S; Kavanaugh, Kevin
2004-01-01
Background Medical education is increasingly being conducted in community-based teaching sites at diverse locations, making it difficult to provide a consistent curriculum. We conducted a randomized trial to assess whether students who viewed digital lectures would perform as well on a measure of cognitive knowledge as students who viewed live lectures. Students' perceptions of the digital lecture format and their opinion as whether a digital lecture format could serve as an adequate replacement for live lectures was also assessed. Methods Students were randomized to either attend a lecture series at our main campus or view digital versions of the same lectures at community-based teaching sites. Both groups completed the same examination based on the lectures, and the group viewing the digital lectures completed a feedback form on the digital format. Results There were no differences in performance as measured by means or average rank. Despite technical problems, the students who viewed the digital lectures overwhelmingly felt the digital lectures could replace live lectures. Conclusions This study provides preliminary evidence digital lectures can be a viable alternative to live lectures as a means of delivering didactic presentations in a community-based setting. PMID:15569389
Rescue and Calibration of NIMBUS 1-4 IR Film Products, 1964 TO 1972
NASA Astrophysics Data System (ADS)
Morgan, T.; Campbell, G. G.
2017-12-01
Digital data exists from the high resolution infrared instruments on Nimbus 1 to 4 for about 1/4 of the possible orbits for parts of 1964, 1966, 1969 and 1970. We are now digitizing and navigating 35 mm film products from those instruments into digital files. Some of those orbits overlap with the digital data so we can "calibrate" the gray scale pictures into temperatures by comparison. Then that calibration can be extended to orbits with no digital data. This greatly improves the coverage of the night time IR view of the earth. Ultimately these data will be inserted into the NASA archive for general use. We will review our progress on this project and discuss an error estimate for the calibration of the HRIR (High Resolution Infrared Radiometer) data from Nimbus 1, 2 and 3 as well as the THIR (Thermal Infrared Radiometer) data on Nimbus 4. These more complete Infrared views of the Earth provide the opportunity to better understand the weather in this period. Comparisons will be made with pre-satellite era reanalysis products.
Generation of optical OFDM signals using 21.4 GS/s real time digital signal processing.
Benlachtar, Yannis; Watts, Philip M; Bouziane, Rachid; Milder, Peter; Rangaraj, Deepak; Cartolano, Anthony; Koutsoyannis, Robert; Hoe, James C; Püschel, Markus; Glick, Madeleine; Killey, Robert I
2009-09-28
We demonstrate a field programmable gate array (FPGA) based optical orthogonal frequency division multiplexing (OFDM) transmitter implementing real time digital signal processing at a sample rate of 21.4 GS/s. The QPSK-OFDM signal is generated using an 8 bit, 128 point inverse fast Fourier transform (IFFT) core, performing one transform per clock cycle at a clock speed of 167.2 MHz and can be deployed with either a direct-detection or a coherent receiver. The hardware design and the main digital signal processing functions are described, and we show that the main performance limitation is due to the low (4-bit) resolution of the digital-to-analog converter (DAC) and the 8-bit resolution of the IFFT core used. We analyze the back-to-back performance of the transmitter generating an 8.36 Gb/s optical single sideband (SSB) OFDM signal using digital up-conversion, suitable for direct-detection. Additionally, we use the device to transmit 8.36 Gb/s SSB OFDM signals over 200 km of uncompensated standard single mode fiber achieving an overall BER<10(-3).
FERMI: a digital Front End and Readout MIcrosystem for high resolution calorimetry
NASA Astrophysics Data System (ADS)
Alexanian, H.; Appelquist, G.; Bailly, P.; Benetta, R.; Berglund, S.; Bezamat, J.; Blouzon, F.; Bohm, C.; Breveglieri, L.; Brigati, S.; Cattaneo, P. W.; Dadda, L.; David, J.; Engström, M.; Genat, J. F.; Givoletti, M.; Goggi, V. G.; Gong, S.; Grieco, G. M.; Hansen, M.; Hentzell, H.; Holmberg, T.; Höglund, I.; Inkinen, S. J.; Kerek, A.; Landi, C.; Ledortz, O.; Lippi, M.; Lofstedt, B.; Lund-Jensen, B.; Maloberti, F.; Mutz, S.; Nayman, P.; Piuri, V.; Polesello, G.; Sami, M.; Savoy-Navarro, A.; Schwemling, P.; Stefanelli, R.; Sundblad, R.; Svensson, C.; Torelli, G.; Vanuxem, J. P.; Yamdagni, N.; Yuan, J.; Ödmark, A.; Fermi Collaboration
1995-02-01
We present a digital solution for the front-end electronics of high resolution calorimeters at future colliders. It is based on analogue signal compression, high speed {A}/{D} converters, a fully programmable pipeline and a digital signal processing (DSP) chain with local intelligence and system supervision. This digital solution is aimed at providing maximal front-end processing power by performing waveform analysis using DSP methods. For the system integration of the multichannel device a multi-chip, silicon-on-silicon multi-chip module (MCM) has been adopted. This solution allows a high level of integration of complex analogue and digital functions, with excellent flexibility in mixing technologies for the different functional blocks. This type of multichip integration provides a high degree of reliability and programmability at both the function and the system level, with the additional possibility of customising the microsystem to detector-specific requirements. For enhanced reliability in high radiation environments, fault tolerance strategies, i.e. redundancy, reconfigurability, majority voting and coding for error detection and correction, are integrated into the design.
Assessment of HRSC Digital Terrain Models Produced for the South Polar Residual Cap
NASA Astrophysics Data System (ADS)
Putri, Alfiah Rizky Diana; Sidiropoulos, Panagiotis; Muller, Jan-Peter
2017-04-01
The current Digital Terrain Models available for Mars consist of NASA MOLA (Mars Orbital Laser Altimeter) Digital Terrain Models with an average resolution of 112 m/ pixel (512 pixels/degree) for the polar region. The ESA/DLR High Resolution Stereo Camera is currently orbiting Mars and mapping its surface, 98% with resolution of ≤100 m/pixel and better and 100% at lower resolution [1]. It is possible to produce Digital Terrain Models from HRSC images using various methods. In this study, the method developed on Kim and Muller [2] which uses the VICAR open source program together with photogrammetry sofrware from DLR (Deutschen Zentrums für Luft- und Raumfahrt) with image matching based on the GOTCHA (Gruen-Otto-Chau) algorithm [3]. Digital Terrain Models have been processed over the South Pole with emphasis on areas around South Polar Residual Cap from High Resolution Stereo Camera images [4]. Digital Terrain Models have been produced for 31 orbits out of 149 polar orbits available. This study analyses the quality of the DTMs including an assessment of accuracy of elevations using the MOLA MEGDR (Mission Experiment Gridded Data Records) which has roughly 42 million MOLA PEDR (Precision Experiment Data Records) points between latitudes of 78 o -90 o S. The issues encountered in the production of Digital Terrain Models will be described and the statistical results and assessment method will be presented. The resultant DTMs will be accessible via http://i-Mars.eu/web-GIS References: [1] Neukum, G. et. al, 2004. Mars Express: The Scientific Payload pp. 17-35. [2] Kim, J.-R. and J.-P. Muller. 2009. PSS vol. 57, pp. 2095-2112. [3] Shin, D. and J.-P. Muller. 2012. Pattern Recognition, 45(10), 3795 -3809. [4] Putri, A.R. D., et al., Int. Arch. Photogramm. Remote Sens. Spatial Inf. Sci., XLI-B4, 463-469 Acknowledgements: The research leading to these results has received partial funding from the STFC "MSSL Consolidated Grant" ST/K000977/1 and partial support from the European Union's Seventh Framework Programme (FP7/2007-2013) under iMars grant agreement n ˚ 607379. The first author would like to acknowledge support for her studies from Indonesia Endowment Fund for Education (LPDP), Ministry of Finance, Republic of Indonesia. The authors would also like to thank Alexander Dumke (Freie Universitaet Berlin) for providing the EXTORI exterior orientation elements which were critical in the production of accuracy geolocations.
NASA Astrophysics Data System (ADS)
Ryan, Jonathan C.; Hubbard, Alun; Box, Jason E.; Brough, Stephen; Cameron, Karen; Cook, Joseph M.; Cooper, Matthew; Doyle, Samuel H.; Edwards, Arwyn; Holt, Tom; Irvine-Fynn, Tristram; Jones, Christine; Pitcher, Lincoln H.; Rennermalm, Asa K.; Smith, Laurence C.; Stibal, Marek; Snooke, Neal
2017-05-01
Measurements of albedo are a prerequisite for modelling surface melt across the Earth's cryosphere, yet available satellite products are limited in spatial and/or temporal resolution. Here, we present a practical methodology to obtain centimetre resolution albedo products with accuracies of 5% using consumer-grade digital camera and unmanned aerial vehicle (UAV) technologies. Our method comprises a workflow for processing, correcting and calibrating raw digital images using a white reference target, and upward and downward shortwave radiation measurements from broadband silicon pyranometers. We demonstrate the method with a set of UAV sorties over the western, K-sector of the Greenland Ice Sheet. The resulting albedo product, UAV10A1, covers 280 km2, at a resolution of 20 cm per pixel and has a root-mean-square difference of 3.7% compared to MOD10A1 and 4.9% compared to ground-based broadband pyranometer measurements. By continuously measuring downward solar irradiance, the technique overcomes previous limitations due to variable illumination conditions during and between surveys over glaciated terrain. The current miniaturization of multispectral sensors and incorporation of upward facing radiation sensors on UAV packages means that this technique will likely become increasingly attractive in field studies and used in a wide range of applications for high temporal and spatial resolution surface mapping of debris, dust, cryoconite and bioalbedo and for directly constraining surface energy balance models.
CytometryML: a markup language for analytical cytology
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Leif, Stephanie H.; Leif, Suzanne B.
2003-06-01
Cytometry Markup Language, CytometryML, is a proposed new analytical cytology data standard. CytometryML is a set of XML schemas for encoding both flow cytometry and digital microscopy text based data types. CytometryML schemas reference both DICOM (Digital Imaging and Communications in Medicine) codes and FCS keywords. These schemas provide representations for the keywords in FCS 3.0 and will soon include DICOM microscopic image data. Flow Cytometry Standard (FCS) list-mode has been mapped to the DICOM Waveform Information Object. A preliminary version of a list mode binary data type, which does not presently exist in DICOM, has been designed. This binary type is required to enhance the storage and transmission of flow cytometry and digital microscopy data. Index files based on Waveform indices will be used to rapidly locate the cells present in individual subsets. DICOM has the advantage of employing standard file types, TIF and JPEG, for Digital Microscopy. Using an XML schema based representation means that standard commercial software packages such as Excel and MathCad can be used to analyze, display, and store analytical cytometry data. Furthermore, by providing one standard for both DICOM data and analytical cytology data, it eliminates the need to create and maintain special purpose interfaces for analytical cytology data thereby integrating the data into the larger DICOM and other clinical communities. A draft version of CytometryML is available at www.newportinstruments.com.
de Carvalho, Lilian Regina; Évora, Yolanda Dora Martinez; Zem-Mascarenhas, Silvia Helena
2016-01-01
ABSTRACT Objective: to assess the usability of a digital learning technology prototype as a new method for minimally invasive monitoring of intracranial pressure. Method: descriptive study using a quantitative approach on assessing the usability of a prototype based on Nielsen's ten heuristics. Four experts in the area of Human-Computer interaction participated in the study. Results: the evaluation delivered eight violated heuristics and 31 usability problems in the 32 screens of the prototype. Conclusion: the suggestions of the evaluators were critical for developing an intuitive, user-friendly interface and will be included in the final version of the digital learning technology. PMID:27579932
Measurements methodology for evaluation of Digital TV operation in VHF high-band
NASA Astrophysics Data System (ADS)
Pudwell Chaves de Almeida, M.; Vladimir Gonzalez Castellanos, P.; Alfredo Cal Braz, J.; Pereira David, R.; Saboia Lima de Souza, R.; Pereira da Soledade, A.; Rodrigues Nascimento Junior, J.; Ferreira Lima, F.
2016-07-01
This paper describes the experimental setup of field measurements carried out for evaluating the operation of the ISDB-TB (Integrated Services Digital Broadcasting, Terrestrial, Brazilian version) standard digital TV in the VHF-highband. Measurements were performed in urban and suburban areas in a medium-sized Brazilian city. Besides the direct measurements of received power and environmental noise, a measurement procedure involving the injection of Gaussian additive noise was employed to achieve the signal to noise ratio threshold at each measurement site. The analysis includes results of static reception measurements for evaluating the received field strength and the signal to noise ratio thresholds for correct signal decoding.
Performance comparison of denoising filters for source camera identification
NASA Astrophysics Data System (ADS)
Cortiana, A.; Conotter, V.; Boato, G.; De Natale, F. G. B.
2011-02-01
Source identification for digital content is one of the main branches of digital image forensics. It relies on the extraction of the photo-response non-uniformity (PRNU) noise as a unique intrinsic fingerprint that efficiently characterizes the digital device which generated the content. Such noise is estimated as the difference between the content and its de-noised version obtained via denoising filter processing. This paper proposes a performance comparison of different denoising filters for source identification purposes. In particular, results achieved with a sophisticated 3D filter are presented and discussed with respect to state-of-the-art denoising filters previously employed in such a context.
Advanced distributed simulation technology: Digital Voice Gateway Reference Guide
NASA Astrophysics Data System (ADS)
Vanhook, Dan; Stadler, Ed
1994-01-01
The Digital Voice Gateway (referred to as the 'DVG' in this document) transmits and receives four full duplex encoded speech channels over the Ethernet. The information in this document applies only to DVG's running firmware of the version listed on the title page. This document, previously named Digital Voice Gateway Reference Guide, BBN Systems and Technologies Corporation, Cambridge, MA 02138, was revised for revision 2.00. This new revision changes the network protocol used by the DVG, to comply with the SINCGARS radio simulation (For SIMNET 6.6.1). Because of the extensive changes to revision 2.00 a separate document was created rather than supplying change pages.
Xu, Yiming; Smith, Scot E; Grunwald, Sabine; Abd-Elrahman, Amr; Wani, Suhas P; Nair, Vimala D
2017-09-11
Digital soil mapping (DSM) is gaining momentum as a technique to help smallholder farmers secure soil security and food security in developing regions. However, communications of the digital soil mapping information between diverse audiences become problematic due to the inconsistent scale of DSM information. Spatial downscaling can make use of accessible soil information at relatively coarse spatial resolution to provide valuable soil information at relatively fine spatial resolution. The objective of this research was to disaggregate the coarse spatial resolution soil exchangeable potassium (K ex ) and soil total nitrogen (TN) base map into fine spatial resolution soil downscaled map using weighted generalized additive models (GAMs) in two smallholder villages in South India. By incorporating fine spatial resolution spectral indices in the downscaling process, the soil downscaled maps not only conserve the spatial information of coarse spatial resolution soil maps but also depict the spatial details of soil properties at fine spatial resolution. The results of this study demonstrated difference between the fine spatial resolution downscaled maps and fine spatial resolution base maps is smaller than the difference between coarse spatial resolution base maps and fine spatial resolution base maps. The appropriate and economical strategy to promote the DSM technique in smallholder farms is to develop the relatively coarse spatial resolution soil prediction maps or utilize available coarse spatial resolution soil maps at the regional scale and to disaggregate these maps to the fine spatial resolution downscaled soil maps at farm scale.
NASA Astrophysics Data System (ADS)
Honeyman-Buck, Janice C.; Huda, Walter; Palmer, Carole K.; Frost, Meryll M.; Moser, Robert; Staab, Edward V.
1995-04-01
A cost effectiveness study on the feasibility of using computed radiography (CR) instead of screen-film methods for portable radiographs indicates that we could only justify CR if film were eliminated. Before purchasing CR equipment, we needed to evaluate the use of softcopy to replace film for routine clinical use. The evaluation had to cover image quality, human factors, and efficiency measures. Screen-film radiographs were digitized and used to simulate CR in two studies. The first study evaluated the quality of digitized images and the workstation user interface. Twenty-one radiographs were selected at random from scopes in the radiology department, were digitized, and transferred to a megascan workstation. Five radiologists were asked to assess the quality of the images and the ease of operation of the workstation while an observer recorded their comments and scores. The second study evaluated the feasibility of using the workstation in a clinical environment. Four radiologists read adult and pediatric portable images in film and softcopy format. Reports were evaluated for differences and timing statistics were kept. The results of the first study indicate that image quality may be acceptable for diagnostic purposes and suggests some changes in the user interface. Newborn infant images were the least acceptable in softcopy, largely due to magnification artifacts introduced when viewing very small images. The evaluation was based on a digitizer as a simulator for a CR unit and the digitizer did not exhibit the same resolution characteristics as CR. Films that were unacceptable from the digitizer are expected to be acceptable with CR. The results of the second study indicated that the high resolution diagnostic workstation could be used in a clinical setting, and that the diagnostic readings were not significantly different between film and softcopy displays. The results also indicated that, depending on the radiologist and the type of images, more time was required to read from the workstation and that the increased time was spent using window/level and magnification/roam functions. This preliminary study suggests that the high resolution workstation developed at the University of Florida has adequate quality and functionality to be used for diagnostic interpretation of portable radiographs if given high resolution images. However, further investigation is indicated before we eliminate film in a CR environment.
TDC Array Tradeoffs in Current and Upcoming Digital SiPM Detectors for Time-of-Flight PET
NASA Astrophysics Data System (ADS)
Tétrault, Marc-André; Therrien, Audrey Corbeil; Lemaire, William; Fontaine, Réjean; Pratte, Jean-François
2017-03-01
Radiation detection used in positron emission tomography (PET) exploits the timing information to remove background noise and refine position measurement through time-of-flight information. Fine time resolution in the order of 10 ps full-width at half-maximum (FWHM) would not only improve contrast in the image, but would also enable direct image reconstruction without iterative or back-projected algorithms. Currently, PET experimental setups based on silicon photomultipliers (SiPMs) reach 73 ps FWHM, where the scintillation process plays the larger role in spreading the timing resolution. This will change with the optimization of faster light emission mechanisms (prompt photons), where readout optoelectronics will once more have a noticeable contribution to the timing resolution limit. In addition to reducing electronic jitter as much as possible, other aspects of the design space must also explored, especially for digital SiPMs. Unlike traditional SiPMs, digital SiPMs can integrate circuits like time-to-digital converters (TDCs) directly with individual or groups of light sensing cells. Designers should consider the number of TDCs to integrate, the area they occupy, their power consumption, their resolution, and the impact of signal processing algorithms and find a compromise with the figure of merit and the coincidence timing resolution (CTR). This paper presents a parametric simulation flow for digital SiPM microsystems that evaluates CTR based on these aspects and on the best linear unbiased estimator (BLUE) in order to guide their design for present and future PET systems. For a small 1.1 × 1.1 × 3.0 mm3 LYSO crystal, the simulations indicate that for a low jitter digital SiPM microsystem with 18.2% photon detection efficiency, fewer than four timestamps with any multi-TDC configuration scheme nearly obtain the optimal CTR with BLUE (just below 100 ps FWHM), but with limited 5% improvement over only using the first observed photon. On the other hand, if a similar crystal but with 2.5% prompt photon fraction is considered, BLUE provides an improvement between 80% and 200% (depending on electronic jitter) over using only the first observed photon. In this case, a few tens of timestamps are required, yielding very different design guidelines than for standard LYSO scintillators.
2011-04-12
This is an enhanced contrast version of the first Mars photograph released on July 15, 1965. This is man first close-up photograph of another planet, a photographic representation of digital data radioed from Mars by the Mariner 4 spacecraft.
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-01-01
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera. PMID:26959023
Feng, Wei; Zhang, Fumin; Qu, Xinghua; Zheng, Shiwei
2016-03-04
High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device) or CMOS (complementary metal oxide semiconductor) camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD) camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second) gain in temporal resolution by using a 25 fps camera.
Registering Thematic Mapper imagery to digital elevation models
NASA Technical Reports Server (NTRS)
Frew, J.
1984-01-01
The problems encountered when attempting to register Landsat Thematic Mapper (TM) data to U.S. geological survey digital elevation models (DEMs) are examined. It is shown that TM and DEM data are not available in the same map projection, necessitating geometric transformation of one of the data type, that the TM data are not accurately located in their nominal projection, and that TM data have higher resolution than most DEM data, but oversampling the DEM data to TM resolution introduces systematic noise. Further work needed in this area is discussed.
High resolution upgrade of the ATF damping ring BPM system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terunuma, N.; Urakawa, J.; /KEK, Tsukuba
2008-05-01
A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished in its first stage, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital downconversion techniques, digital signal processing, and also tests a new automatic gain error correction schema. The technical concept and realization, as well as preliminary results of beam studies are presented.
NASA Astrophysics Data System (ADS)
Korotenko, K.
2003-04-01
An ultra-high-resolution version of DieCAST was adjusted for the Adriatic Sea and coupled with an oil spill model. Hydrodynamic module was developed on base of th low dissipative, four-order-accuracy version DieCAST with the resolution of ~2km. The oil spill model was developed on base of particle tracking technique The effect of evaporation is modeled with an original method developed on the base of the pseudo-component approach. A special dialog interface of this hybrid system allowing direct coupling to meteorlogical data collection systems or/and meteorological models. Experiments with hypothetic oil spill are analyzed for the Northern Adriatic Sea. Results (animations) of mesoscale circulation and oil slick modeling are presented at wabsite http://thayer.dartmouth.edu/~cushman/adriatic/movies/
Schmidt, James R.; Liefooghe, Baptist
2016-01-01
This report presents data from two versions of the task switching procedure in which the separate influence of stimulus repetitions, response key repetitions, conceptual response repetitions, cue repetitions, task repetitions, and congruency are considered. Experiment 1 used a simple alternating runs procedure with parity judgments of digits and consonant/vowel decisions of letters as the two tasks. Results revealed sizable effects of stimulus and response repetitions, and controlling for these effects reduced the switch cost. Experiment 2 was a cued version of the task switch paradigm with parity and magnitude judgments of digits as the two tasks. Results again revealed large effects of stimulus and response repetitions, in addition to cue repetition effects. Controlling for these effects again reduced the switch cost. Congruency did not interact with our novel “unbiased” measure of switch costs. We discuss how the task switch paradigm might be thought of as a more complex version of the feature integration paradigm and propose an episodic learning account of the effect. We further consider to what extent appeals to higher-order control processes might be unnecessary and propose that controls for feature integration biases should be standard practice in task switching experiments. PMID:26964102
Mesoscale landscape model of gypsy moth phenology
Joseph M. Russo; John G. W. Kelley; Andrew M. Liebhold
1991-01-01
A recently-developed high resolution climatological temperature data base was input into a gypsy moth phenology model. The high resolution data were created from a coupling of 30-year averages of station observations and digital elevation data. The resultant maximum and minimum temperatures have about a 1 km resolution which represents meteorologically the mesoscale....
A key factor for improving models of ecosystem benefits is the availability of high quality spatial data. High resolution LIDAR data are now commonly available and can be used to produce more accurate model outputs. However, increased resolution leads to higher computer resource...
Completion of the 2006 National Land Cover Database Update for the Conterminous United States
Under the organization of the Multi-Resolution Land Characteristics (MRLC) Consortium, the National Land Cover Database (NLCD) has been updated to characterize both land cover and land cover change from 2001 to 2006. An updated version of NLCD 2001 (Version 2.0) is also provided....
Digital Astronaut Photography: A Discovery Dataset for Archaeology
NASA Technical Reports Server (NTRS)
Stefanov, William L.
2010-01-01
Astronaut photography acquired from the International Space Station (ISS) using commercial off-the-shelf cameras offers a freely-accessible source for high to very high resolution (4-20 m/pixel) visible-wavelength digital data of Earth. Since ISS Expedition 1 in 2000, over 373,000 images of the Earth-Moon system (including land surface, ocean, atmospheric, and lunar images) have been added to the Gateway to Astronaut Photography of Earth online database (http://eol.jsc.nasa.gov ). Handheld astronaut photographs vary in look angle, time of acquisition, solar illumination, and spatial resolution. These attributes of digital astronaut photography result from a unique combination of ISS orbital dynamics, mission operations, camera systems, and the individual skills of the astronaut. The variable nature of astronaut photography makes the dataset uniquely useful for archaeological applications in comparison with more traditional nadir-viewing multispectral datasets acquired from unmanned orbital platforms. For example, surface features such as trenches, walls, ruins, urban patterns, and vegetation clearing and regrowth patterns may be accentuated by low sun angles and oblique viewing conditions (Fig. 1). High spatial resolution digital astronaut photographs can also be used with sophisticated land cover classification and spatial analysis approaches like Object Based Image Analysis, increasing the potential for use in archaeological characterization of landscapes and specific sites.
Integrated High Resolution Digital Color Light Sensor in 130 nm CMOS Technology.
Strle, Drago; Nahtigal, Uroš; Batistell, Graciele; Zhang, Vincent Chi; Ofner, Erwin; Fant, Andrea; Sturm, Johannes
2015-07-22
This article presents a color light detection system integrated in 130 nm CMOS technology. The sensors and corresponding electronics detect light in a CIE XYZ color luminosity space using on-chip integrated sensors without any additional process steps, high-resolution analog-to-digital converter, and dedicated DSP algorithm. The sensor consists of a set of laterally arranged integrated photodiodes that are partly covered by metal, where color separation between the photodiodes is achieved by lateral carrier diffusion together with wavelength-dependent absorption. A high resolution, hybrid, ∑∆ ADC converts each photo diode's current into a 22-bit digital result, canceling the dark current of the photo diodes. The digital results are further processed by the DSP, which calculates normalized XYZ or RGB color and intensity parameters using linear transformations of the three photo diode responses by multiplication of the data with a transformation matrix, where the coefficients are extracted by training in combination with a pseudo-inverse operation and the least-mean square approximation. The sensor system detects the color light parameters with 22-bit accuracy, consumes less than 60 μA on average at 10 readings per second, and occupies approx. 0.8 mm(2) of silicon area (including three photodiodes and the analog part of the ADC). The DSP is currently implemented on FPGA.
Geyer, Stefan H.; Maurer-Gesek, Barbara; Reissig, Lukas F.; Weninger, Wolfgang J.
2017-01-01
We provide simple protocols for generating digital volume data with the high-resolution episcopic microscopy (HREM) method. HREM is capable of imaging organic materials with volumes up to 5 x 5 x 7 mm3 in typical numeric resolutions between 1 x 1 x 1 and 5 x 5 x 5 µm3. Specimens are embedded in methacrylate resin and sectioned on a microtome. After each section an image of the block surface is captured with a digital video camera that sits on the phototube connected to the compound microscope head. The optical axis passes through a green fluorescent protein (GFP) filter cube and is aligned with a position, at which the bock holder arm comes to rest after each section. In this way, a series of inherently aligned digital images, displaying subsequent block surfaces are produced. Loading such an image series in three-dimensional (3D) visualization software facilitates the immediate conversion to digital volume data, which permit virtual sectioning in various orthogonal and oblique planes and the creation of volume and surface rendered computer models. We present three simple, tissue specific protocols for processing various groups of organic specimens, including mouse, chick, quail, frog and zebra fish embryos, human biopsy material, uncoated paper and skin replacement material. PMID:28715372
Geyer, Stefan H; Maurer-Gesek, Barbara; Reissig, Lukas F; Weninger, Wolfgang J
2017-07-07
We provide simple protocols for generating digital volume data with the high-resolution episcopic microscopy (HREM) method. HREM is capable of imaging organic materials with volumes up to 5 x 5 x 7 mm 3 in typical numeric resolutions between 1 x 1 x 1 and 5 x 5 x 5 µm 3 . Specimens are embedded in methacrylate resin and sectioned on a microtome. After each section an image of the block surface is captured with a digital video camera that sits on the phototube connected to the compound microscope head. The optical axis passes through a green fluorescent protein (GFP) filter cube and is aligned with a position, at which the bock holder arm comes to rest after each section. In this way, a series of inherently aligned digital images, displaying subsequent block surfaces are produced. Loading such an image series in three-dimensional (3D) visualization software facilitates the immediate conversion to digital volume data, which permit virtual sectioning in various orthogonal and oblique planes and the creation of volume and surface rendered computer models. We present three simple, tissue specific protocols for processing various groups of organic specimens, including mouse, chick, quail, frog and zebra fish embryos, human biopsy material, uncoated paper and skin replacement material.
ERIC Educational Resources Information Center
Fokides, Emmanuel
2016-01-01
Immigrant students face a multitude of problems, among which are poor social adaptation and school integration. On the other hand, although digital narrations are widely used in education, they are rarely used for aiding students or for the resolution of complex problems. This study exploits the potential of digital narrations towards this end, by…
Ma, Shuoxin; Yu, Hong; Jin, Yu-Biao; Zheng, Jun
2018-01-01
Background The smartphone-based whole slide imaging (WSI) system represents a low-cost and effective alternative to automatic scanners for telepathology. In a previous study, the development of one such solution, named scalable whole slide imaging (sWSI), was presented and analyzed. A clinical evaluation of its iOS version with 100 frozen section samples verified the diagnosis-readiness of the produced virtual slides. Objective The first aim of this study was to delve into the quantifying issues encountered in the development of an Android version. It should also provide insights into future high-resolution real-time feedback medical imaging apps on Android and invoke the awareness of smartphone manufacturers for collaboration. The second aim of this study was to further verify the clinical value of sWSI with cytology samples. This type is different from the frozen section samples in that they require finer detail on the cellular level. Methods During sWSI development on Android, it was discovered that many models do not support uncompressed camera pixel data with sufficient resolution and full field of view. The proportion of models supporting the optimal format was estimated in a test on 200 mainstream Android models. Other factors, including slower processing speed and camera preview freezing, also led to inferior performance of sWSI on Android compared with the iOS version. The processing speed was mostly determined by the central processing unit frequency in theory, and the relationship was investigated in the 200-model simulation experiment with physical devices. The camera preview freezing was caused by the lag between triggering photo capture and resuming preview. In the clinical evaluation, 100 ThinPrep cytology test samples covering 6 diseases were scanned with sWSI and compared against the ground truth of optical microscopy. Results Among the tested Android models, only 3.0% (6/200) provided an optimal data format, meeting all criteria of quality and efficiency. The image-processing speed demonstrated a positive relationship with the central processing unit frequency but to a smaller degree than expected and was highly model-dependent. The virtual slides produced by sWSI on Android and iOS of ThinPrep cytology test samples achieved similar high quality. Using optical microscopy as the ground truth, pathologists made a correct diagnosis on 87.5% (175/200) of the cases with sWSI virtual slides. Depending on the sWSI version and the pathologist in charge, the kappa value varied between .70 and .82. All participating pathologists considered the quality of the sWSI virtual slides in the experiment to be adequate for routine usage. Conclusions Limited by hardware and operating system support, the performance of sWSI on mainstream Android smartphones did not fully match the iOS version. However, in practice, this difference was not significant, and both were adequate for digitizing most of the sample types for telepathology consultation. PMID:29618454
RHODE ISLAND DIGITAL ORTHOPHOTO QUADRANGLE MOSAIC
Orthophotos combine the image characteristics of a photograph with the geometric qualities of a map. The primary digital orthophotoquad (DOQ) is a 1-meter ground resolution, quarter-quadrangle (3.75-minutes of latitude by 3.75-minutes of longitude) image cast on the Universal Tra...
Frequency-specific insight into short-term memory capacity.
Feurra, Matteo; Galli, Giulia; Pavone, Enea Francesco; Rossi, Alessandro; Rossi, Simone
2016-07-01
The digit span is one of the most widely used memory tests in clinical and experimental neuropsychology for reliably measuring short-term memory capacity. In the forward version, sequences of digits of increasing length have to be reproduced in the order in which they are presented, whereas in the backward version items must be reproduced in the reversed order. Here, we assessed whether transcranial alternating current stimulation (tACS) increases the memory span for digits of young and midlife adults. Imperceptibly weak electrical currents in the alpha (10 Hz), beta (20 Hz), theta (5 Hz), and gamma (40 Hz) range, as well as a sham stimulation, were delivered over the left posterior parietal cortex, a cortical region thought to sustain maintenance processes in short-term memory through oscillatory brain activity in the beta range. We showed a frequency-specific effect of beta-tACS that robustly increased the forward memory span of young, but not middle-aged, healthy individuals. The effect correlated with age: the younger the subjects, the greater the benefit arising from parietal beta stimulation. Our results provide evidence of a short-term memory capacity improvement in young adults by online frequency-specific tACS application. Copyright © 2016 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Münster, S.; Kuroczyński, P.; Pfarr-Harfst, M.; Grellert, M.; Lengyel, D.
2015-08-01
The workgroup for Digital Reconstruction of the Digital Humanities in the German-speaking area association (Digital Humanities im deutschsprachigen Raum e.V.) was founded in 2014 as cross-disciplinary scientific society dealing with all aspects of digital reconstruction of cultural heritage and currently involves more than 40 German researchers. Moreover, the workgroup is dedicated to synchronise and foster methodological research for these topics. As one preliminary result a memorandum was created to name urgent research challenges and prospects in a condensed way and assemble a research agenda which could propose demands for further research and development activities within the next years. The version presented within this paper was originally created as a contribution to the so-called agenda development process initiated by the German Federal Ministry of Education and Research (BMBF) in 2014 and has been amended during a joint meeting of the digital reconstruction workgroup in November 2014.
NASA Astrophysics Data System (ADS)
Świąder, Andrzej
2014-12-01
Digital Terrain Models (DTMs) produced from stereoscopic, submeter-resolution High Resolution Imaging Science Experiment (HiRISE) imagery provide a solid basis for all morphometric analyses of the surface of Mars. In view of the fact that a more effective use of DTMs is hindered by complicated and time-consuming manual handling, the automated process provided by specialists of the Ames Intelligent Robotics Group (NASA), Ames Stereo Pipeline, constitutes a good alternative. Four DTMs, covering the global dichotomy boundary between the southern highlands and northern lowlands along the line of the presumable Arabia shoreline, were produced and analysed. One of them included forms that are likely to be indicative of an oceanic basin that extended across the lowland northern hemisphere of Mars in the geological past. The high resolution DTMs obtained were used in the process of landscape visualisation.
Cheng, Li-Chung; Lien, Chi-Hsiang; Da Sie, Yong; Hu, Yvonne Yuling; Lin, Chun-Yu; Chien, Fan-Ching; Xu, Chris; Dong, Chen Yuan; Chen, Shean-Jen
2014-01-01
In this study, the light diffraction of temporal focusing multiphoton excitation microscopy (TFMPEM) and the excitation patterning of nonlinear structured-illumination microscopy (NSIM) can be simultaneously and accurately implemented via a single high-resolution digital micromirror device. The lateral and axial spatial resolutions of the TFMPEM are remarkably improved through the second-order NSIM and projected structured light, respectively. The experimental results demonstrate that the lateral and axial resolutions are enhanced from 397 nm to 168 nm (2.4-fold) and from 2.33 μm to 1.22 μm (1.9-fold), respectively, in full width at the half maximum. Furthermore, a three-dimensionally rendered image of a cytoskeleton cell featuring ~25 nm microtubules is improved, with other microtubules at a distance near the lateral resolution of 168 nm also able to be distinguished. PMID:25136483
Hyper-Resolution Groundwater Modeling using MODFLOW 6
NASA Astrophysics Data System (ADS)
Hughes, J. D.; Langevin, C.
2017-12-01
MODFLOW 6 is the latest version of the U.S. Geological Survey's modular hydrologic model. MODFLOW 6 was developed to synthesize many of the recent versions of MODFLOW into a single program, improve the way different process models are coupled, and to provide an object-oriented framework for adding new types of models and packages. The object-oriented framework and underlying numerical solver make it possible to tightly couple any number of hyper-resolution models within coarser regional models. The hyper-resolution models can be used to evaluate local-scale groundwater issues that may be affected by regional-scale forcings. In MODFLOW 6, hyper-resolution meshes can be maintained as separate model datasets, similar to MODFLOW-LGR, which simplifies the development of a coarse regional model with imbedded hyper-resolution models from a coarse regional model. For example, the South Atlantic Coastal Plain regional water availability model was converted from a MODFLOW-2000 model to a MODFLOW 6 model. The horizontal discretization of the original model is approximately 3,218 m x 3,218 m. Hyper-resolution models of the Aiken and Sumter County water budget areas in South Carolina with a horizontal discretization of approximately 322 m x 322 m were developed and were tightly coupled to a modified version of the original coarse regional model that excluded these areas. Hydraulic property and aquifer geometry data from the coarse model were mapped to the hyper-resolution models. The discretization of the hyper-resolution models is fine enough to make detailed analyses of the effect that changes in groundwater withdrawals in the production aquifers have on the water table and surface-water/groundwater interactions. The approach used in this analysis could be applied to other regional water availability models that have been developed by the U.S. Geological Survey to evaluate local scale groundwater issues.
NASA Technical Reports Server (NTRS)
Ungar, Stephen G.; Merry, Carolyn J.; Mckim, Harlan L.; Irish, Richard; Miller, Michael S.
1988-01-01
A simulated data set was used to evaluate techniques for extracting topography from side-looking satellite systems for an area of northwest Washington state. A negative transparency orthophotoquad was digitized at a spacing of 85 microns, resulting in an equivalent ground distance of 9.86 m between pixels and a radiometric resolution of 256 levels. A bilinear interpolation was performed on digital elevation model data to generate elevation data at a 9.86-m resolution. The nominal orbital characteristics and geometry of the SPOT satellite were convoluted with the data to produce simulated panchromatic HRV digital stereo imagery for three different orbital paths and techniques for reconstructing topographic data were developed. Analyses with the simulated HRV data and other data sets show that the method is effective.
NASA Astrophysics Data System (ADS)
Vallerga, John; McPhate, Jason; Tremsin, Anton; Siegmund, Oswald; Raffanti, Rick; Cumming, Harley; Seljak, Andrej; Virta, Vihtori; Varner, Gary
2016-07-01
Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last three decades (e.g. EUVE, FUSE, COS on Hubble etc.) and been mentioned for instruments on future large telescopes in space such as LUVOIR14. Using cross strip anodes, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x 1000) and output event rate (x100), all the while operating at lower gain (x10) resulting in lower high voltage requirements and longer MCP lifetimes. A crossed strip anode MCP readout starts with a set of orthogonal conducting strips (e.g. 80 x 80), typically spaced at a 635 micron pitch onto which charge clouds from MCP amplified events land. Each strip has its own charge sensitive amplifier that is sampled continuously by a dedicated analog to digital converter (ADC). All of the ADC digital output lines are fed into a field programmable gate array (FGPA) which can detect charge events landing on the strips, measure the peak amplitudes of those charge events and calculate their spatial centroid along with their time of arrival (X,Y,T) and pass this information to a downstream computer. Laboratory versions of these electronics have demonstrated < 20 microns FWHM spatial resolution, count rates on the order of 2 MHz, and temporal resolution of 1ns. In 2012 our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a NASA Strategic Astrophysics Technology (SAT) grant to raise the TRL of a cross strip detector from 4 to 6 by replacing most of the 19" rack mounted, high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass, and volume requirements of the detector electronics. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration). ASICs designed for this program have been successfully fabricated and are undergoing extensive testing. We will present the latest progress on these ASIC designs and their performance. We will also show our preliminary work on scaling these designs (detector and electronics) to a flight qualified 100 x 100 mm cross strip detector, which has recently been funded through a follow on SAT grant.
Funes, Cynthia M; Rodriguez, Juventino Hernandez; Lopez, Steven Regeser
2016-12-01
This study provides a systematic comparison of the norms of 3 Spanish-language Wechsler Adult Intelligence Scales (WAIS-III) batteries from Mexico, Spain, and Puerto Rico, and the U.S. English-language WAIS-III battery. Specifically, we examined the performance of the 4 normative samples on 2 identical subtests (Digit Span and Digit Symbol-Coding) and 1 nearly identical subtest (Block Design). We found that across most age groups the means associated with the Spanish-language versions of the 3 subtests were lower than the means of the U.S. English-language version. In addition, we found that for most age ranges the Mexican subsamples scored lower than the Spanish subsamples. Lower educational levels of Mexicans and Spaniards compared to U.S. residents are consistent with the general pattern of findings. These results suggest that because of the different norms, applying any of the 3 Spanish-language versions of the WAIS-III generally risks underestimating deficits, and that applying the English-language WAIS-III norms risks overestimating deficits of Spanish-speaking adults. There were a few exceptions to these general patterns. For example, the Mexican subsample ages 70 years and above performed significantly better on the Digit Symbol and Block Design than did the U.S. and Spanish subsamples. Implications for the clinical assessment of U.S. Spanish-speaking Latinos and test adaptation are discussed with an eye toward improving the clinical care for this community. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Li, Zeyu; Li, Lei; Qin, Yu; Li, Guangbin; Wang, Du; Zhou, Xun
2016-09-05
We demonstrate the enhancement of resolution and image quality in terahertz (THz) lens-free in-line digital holography by sub-pixel sampling with double-distance reconstruction. Multiple sub-pixel shifted low-resolution (LR) holograms recorded by a pyroelectric array detector (100 μm × 100 μm pixel pitch, 124 × 124 pixels) are aligned precisely to synthesize a high-resolution (HR) hologram. By this method, the lateral resolution is no more limited by the pixel pitch, and lateral resolution of 150 μm is obtained, which corresponds to 1.26λ with respect to the illuminating wavelength of 118.8 μm (2.52 THz). Compared with other published works, to date, this is the highest resolution in THz digital holography when considering the illuminating wavelength. In addition, to suppress the twin-image and zero-order artifacts, the complex amplitude distributions of both object and illuminaing background wave fields are reconstructed simultaneously. This is achieved by iterative phase retrieval between the double HR holograms and background images at two recording planes, which does not require any constraints on object plane or a priori knowledge of the sample.
Optimal design of waveform digitisers for both energy resolution and pulse shape discrimination
NASA Astrophysics Data System (ADS)
Cang, Jirong; Xue, Tao; Zeng, Ming; Zeng, Zhi; Ma, Hao; Cheng, Jianping; Liu, Yinong
2018-04-01
Fast digitisers and digital pulse processing have been widely used for spectral application and pulse shape discrimination (PSD) owing to their advantages in terms of compactness, higher trigger rates, offline analysis, etc. Meanwhile, the noise of readout electronics is usually trivial for organic, plastic, or liquid scintillator with PSD ability because of their poor intrinsic energy resolution. However, LaBr3(Ce) has been widely used for its excellent energy resolution and has been proven to have PSD ability for alpha/gamma particles. Therefore, designing a digital acquisition system for such scintillators as LaBr3(Ce) with both optimal energy resolution and promising PSD ability is worthwhile. Several experimental research studies about the choice of digitiser properties for liquid scintillators have already been conducted in terms of the sampling rate and vertical resolution. Quantitative analysis on the influence of waveform digitisers, that is, fast amplifier (optional), sampling rates, and vertical resolution, on both applications is still lacking. The present paper provides quantitative analysis of these factors and, hence, general rules about the optimal design of digitisers for both energy resolution and PSD application according to the noise analysis of time-variant gated charge integration.
NASA Astrophysics Data System (ADS)
Hoffmeister, Dirk; Kramm, Tanja; Curdt, Constanze; Maleki, Sedigheh; Khormali, Farhad; Kehl, Martin
2016-04-01
The Iranian loess plateau is covered by loess deposits, up to 70 m thick. Tectonic uplift triggered deep erosion and valley incision into the loess and underlying marine deposits. Soil development strongly relates to the aspect of these incised slopes, because on northern slopes vegetation protects the soil surface against erosion and facilitates formation and preservation of a Cambisol, whereas on south-facing slopes soils were probably eroded and weakly developed Entisols formed. While the whole area is intensively stocked with sheep and goat, rain-fed cropping of winter wheat is practiced on the valley floors. Most time of the year, the soil surface is unprotected against rainfall, which is one of the factors promoting soil erosion and serious flooding. However, little information is available on soil distribution, plant cover and the geomorphological evolution of the plateau, as well as on potentials and problems in land use. Thus, digital landform and soil mapping is needed. As a requirement of digital landform and soil mapping, four different landform classification methods were compared and evaluated. These geomorphometric classifications were run on two different scales. On the whole area an ASTER GDEM and SRTM dataset (30 m pixel resolution) was used. Likewise, two high-resolution digital elevation models were derived from Pléiades satellite stereo-imagery (< 1m pixel resolution, 10 by 10 km). The high-resolution information of this dataset was aggregated to datasets of 5 and 10 m scale. The applied classification methods are the Geomorphons approach, an object-based image approach, the topographical position index and a mainly slope based approach. The accuracy of the classification was checked with a location related image dataset obtained in a field survey (n ~ 150) in September 2015. The accuracy of the DEMs was compared to measured DGPS trenches and map-based elevation data. The overall derived accuracy of the landform classification based on the high-resolution DEM with a resolution of 5 m is approximately 70% and on a 10 m resolution >58%. For the 30 m resolution datasets is the achieved accuracy approximately 40%, as several small scale features are not recognizable in this resolution. Thus, for an accurate differentiation between different important landform types, high-resolution datasets are necessary for this strongly shaped area. One major problem of this approach are the different classes derived by each method and the various class annotations. The result of this evaluation will be regarded for the derivation of landform and soil maps.
Karst mapping in the United States: Past, present and future
Weary, David J.; Doctor, Daniel H.
2015-01-01
The earliest known comprehensive karst map of the entire USA was published by Stringfield and LeGrand (1969), based on compilations of William E. Davies of the U.S. Geological Survey (USGS). Various versions of essentially the same map have been published since. The USGS recently published new digital maps and databases depicting the extent of known karst, potential karst, and pseudokarst areas of the United States of America including Puerto Rico and the U.S. Virgin Islands (Weary and Doctor, 2014). These maps are based primarily on the extent of potentially karstic soluble rock types, and rocks with physical properties conducive to the formation of pseudokarst features. These data were compiled and refined from multiple sources at various spatial resolutions, mostly as digital data supplied by state geological surveys. The database includes polygons delineating areas with potential for karst and that are tagged with attributes intended to facilitate classification of karst regions. Approximately 18% of the surface of the fifty United States is underlain by significantly soluble bedrock. In the eastern United States the extent of outcrop of soluble rocks provides a good first-approximation of the distribution of karst and potential karst areas. In the arid western states, the extent of soluble rock outcrop tends to overestimate the extent of regions that might be considered as karst under current climatic conditions, but the new dataset encompasses those regions nonetheless. This database will be revised as needed, and the present map will be updated as new information is incorporated.
Low power data acquisition unit for autonomous geophysical instrumentation
NASA Astrophysics Data System (ADS)
Prystai, Andrii
2017-04-01
The development of an autonomous instrumentation for field research is always a challenge which needs knowledge and application of recent advances in technology and components production. Using this information a super-low power, low-cost, stand-alone GPS time synchronized data acquisition unit was created. It comprises an extended utilization of the microcontroller modules and peripherals and special firmware with flexible PLL parameters. The present report is devoted to a discussion of synchronization mode of data sampling in autonomous field instruments with possibility of GPS random breaks. In the result the achieved sampling timing accuracy is better than ± 60 ns without phase jumps and distortion plus fixed shift depending on the sample rate. The main application of the system is for simultaneous measurement of several channels from magnetic and electric sensors in field conditions for magneto-telluric instruments. First utilization of this system was in the new developed versions of LEMI-026 magnetometer and LEMI-423 field station, where it was applied for digitizing of up to 6 analogue channels with 32-bit resolution in the range ± 2.5V, digital filtration (LPF) and maximum sample rate 4kS/s. It is ready for record in 5 minutes after being turned on. Recently, this system was successfully utilized with the drone-portable magnetometers destined for the search of metallic objects, like UXO, in rural areas, research of engineering underground structure and for mapping ore bodies. The successful tests of drone-portable system were made and tests results are also discussed.
& Legislation Links Discussion Lists Quick Links AAPT eMentoring ComPADRE Review of High School Take Physics" Poster Why Physics Poster Thumbnail Download normal resolution JPEG Download high resolution JPEG Download Spanish Version Recruiting Physics Students in High School (FED newsletter article
Reese, Caitlin S; Suhr, Julie A; Riddle, Tara L
2012-03-01
Prior research shows that Digit Span is a useful embedded measure of malingering. However, the Wechsler Adult Intelligence Scale-IV (Wechsler, 2008) altered Digit Span in meaningful ways, necessitating another look at Digit Span as an embedded measure of malingering. Using a simulated malingerer design, we examined the predictive accuracy of existing Digit Span validity indices and explored whether patterns of performance utilizing the new version would provide additional evidence for malingering. Undergraduates with a history of mild head injury performed with best effort or simulated impaired cognition and were also compared with a large sample of non-head-injured controls. Previously established cutoffs for the age-corrected scaled score and Reliable Digit Span (RDS) performed similarly in the present samples. Patterns of RDS length using all three subscales of the new scale were different in malingerers when compared with both head-injured and non-head-injured controls. Two potential alternative RDS scores were introduced, which showed better sensitivity than the traditional RDS, while retaining specificity to malingering.
Marcinkowski, R; España, S; Van Holen, R; Vandenberghe, S
2014-12-07
The majority of current whole-body PET scanners are based on pixelated scintillator arrays with a transverse pixel size of 4 mm. However, recent studies have shown that decreasing the pixel size to 2 mm can significantly improve image spatial resolution. In this study, the performance of Digital Photon Counter (DPC) from Philips Digital Photon Counting (PDPC) was evaluated to determine their potential for high-resolution whole-body time of flight (TOF) PET scanners. Two detector configurations were evaluated. First, the DPC3200-44-22 DPC array was coupled to a LYSO block of 15 × 15 2 × 2 × 22 mm(3) pixels through a 1 mm thick light guide. Due to light sharing among the dies neighbour logic of the DPC was used. In a second setup the same DPC was coupled directly to a scalable 4 × 4 LYSO matrix of 1.9 × 1.9 × 22 mm(3) crystals with a dedicated reflector arrangement allowing for controlled light sharing patterns inside the matrix. With the first approach an average energy resolution of 14.5% and an average CRT of 376 ps were achieved. For the second configuration an average energy resolution of 11% and an average CRT of 295 ps were achieved. Our studies show that the DPC is a suitable photosensor for a high-resolution TOF-PET detector. The dedicated reflector arrangement allows one to achieve better performances than the light guide approach. The count loss, caused by dark counts, is overcome by fitting the matrix size to the size of DPC single die.
ASTER Global Digital Elevation Model Version 2 - summary of validation results
Tachikawa, Tetushi; Kaku, Manabu; Iwasaki, Akira; Gesch, Dean B.; Oimoen, Michael J.; Zhang, Z.; Danielson, Jeffrey J.; Krieger, Tabatha; Curtis, Bill; Haase, Jeff; Abrams, Michael; Carabajal, C.; Meyer, Dave
2011-01-01
Based on these findings, the GDEM validation team recommends the release of the GDEM2 to the public, acknowledging that, while vastly improved, some artifacts still exist which could affect its utility in certain applications.
Inventing an Online Newspaper.
ERIC Educational Resources Information Center
McAdams, Melinda
1995-01-01
Summarizes the issues, debates, and decisions that helped to shape "The Washington Post's" online service, Digital Ink. Highlights include: differences between online and print versions of the newspaper, structure of the user interface, organization of information, content, searching and navigation, and advertising. (JKP)
NASA Astrophysics Data System (ADS)
Markiewicz, J. S.; Kowalczyk, M.; Podlasiak, P.; Bakuła, K.; Zawieska, D.; Bujakiewicz, A.; Andrzejewska, E.
2013-12-01
Due to considerable development of the non - invasion measurement technologies, taking advantages from the distance measurement, the possibility of data acquisition increased and at the same time the measurement period has been reduced. This, by combination of close range laser scanning data and images, enabled the wider expansion of photogrammetric methods effectiveness in registration and analysis of cultural heritage objects. Mentioned integration allows acquisition of objects three - dimensional models and in addition digital image maps - true - ortho and vector products. The quality of photogrammetric products is defined by accuracy and the range of content, therefore by number and the minuteness of detail. That always depends on initial data geometrical resolution. The research results presented in the following paper concern the quality valuation of two products, image of true - ortho and vector data, created for selected parts of architectural object. Source data is represented by point collection i n cloud, acquired from close range laser scanning and photo images. Both data collections has been acquired with diversified resolutions. The exterior orientation of images and several versions of the true - ortho are based on numeric models of the object, acquired with specified resolutions. The comparison of these products gives the opportunity to rate the influence of initial data resolution on their quality (accuracy, information volume). Additional analysis will be performed on the base of vector product s comparison, acquired from monoplotting and true - ortho images. As a conclusion of experiment it was proved that geometric resolution has significant impact on the possibility of generation and on the accuracy of relative orientation TLS scans. If creation of high - resolution products is considered, scanning resolution of about 2 mm should be applied and in case of architecture details - 1 mm. It was also noted that scanning angle and object structure has significant influence on accuracy and completeness of the data. For creation of true - orthoimages for architecture purposes high - resolution ground - based images in geometry close to normal case are recommended to improve their quality. The use of grayscale true - orthoimages with values from scanner intensity is not advised. Presented research proved also that accuracy of manual and automated vectorisation results depend significantly on the resolution of the generated orthoimages (scans and images resolution) and mainly of blur effect and possible pixel size.
LANDSAT-D investigations in snow hydrology
NASA Technical Reports Server (NTRS)
Dozier, J.
1983-01-01
Progress on the registration of TM data to digital topographic data; on comparison of TM, MSS and NOAA meteorological satellite data for snowcover mapping; and on radiative transfer models for atmospheric correction is reported. Some methods for analyzing spatial contiguity of snow within the snow covered area were selected. The methods are based on a two-channel version of the grey level co-occurence matrix, combined with edge detection derived from an algorithm for computing slopes and exposures from digital terrain data.
NASA Technical Reports Server (NTRS)
1973-01-01
Design and development efforts for a spaceborne modular computer system are reported. An initial baseline description is followed by an interface design that includes definition of the overall system response to all classes of failure. Final versions for the register level designs for all module types were completed. Packaging, support and control executive software, including memory utilization estimates and design verification plan, were formalized to insure a soundly integrated design of the digital computer system.
Wilshire, Howard G.; Bedford, David R.; Coleman, Teresa
2002-01-01
3. Plottable map representations of the database at 1:24,000 scale in PostScript and Adobe PDF formats. The plottable files consist of a color geologic map derived from the spatial database, composited with a topographic base map in the form of the USGS Digital Raster Graphic for the map area. Color symbology from each of these datasets is maintained, which can cause plot file sizes to be large.
An algorithm for approximate rectification of digital aerial images
USDA-ARS?s Scientific Manuscript database
High-resolution aerial photography is one of the most valuable tools available for managing extensive landscapes. With recent advances in digital camera technology, computer hardware, and software, aerial photography is easier to collect, store, and transfer than ever before. Images can be automa...
Variable word length encoder reduces TV bandwith requirements
NASA Technical Reports Server (NTRS)
Sivertson, W. E., Jr.
1965-01-01
Adaptive variable resolution encoding technique provides an adaptive compression pseudo-random noise signal processor for reducing television bandwidth requirements. Complementary processors are required in both the transmitting and receiving systems. The pretransmission processor is analog-to-digital, while the postreception processor is digital-to-analog.
Considerations for applying digital soil mapping to ecological sites
USDA-ARS?s Scientific Manuscript database
Recent advancements in the spatial prediction of soil properties are not currently being fully utilized for ecological studies. Linking digital soil mapping (DSM) with ecological sites (ES) has the potential to better land management decisions by improving spatial resolution and precision as well as...
Operation and tests of a DDC101 A/D
NASA Astrophysics Data System (ADS)
Nguyen, H.
1994-11-01
For the KTeV PMT laser monitoring system, one needs a high resolution device with a large dynamic range to be used for digitizing PIN photodiodes. The dynamic range should be wider than or comparable to the KTeV digitizer (17-bits). The Burr-Brown DDC101 is a precision, wide dynamic range, charge digitizing A/D converter with 20-bit resolution, packaged in a 28-pin plastic, double-wide DP. Low level current output devices such as photosensors can be directly connected to its input. The digital output can be clocked-out serially from the pins. For typical operations, a relatively wide gate of 1 msec should be used. The full scale charge is 500 pC for unipolar mode. The bipolar mode scale is +/- 250 pC. The advertised integral nonlinearity is 0.003% of FSR. This document describes only the basic DDC101 operations since full detail can be found in the DDC101 manual. Tests results are given in section 3.
D Digitization of AN Heritage Masterpiece - a Critical Analysis on Quality Assessment
NASA Astrophysics Data System (ADS)
Menna, F.; Nocerino, E.; Remondino, F.; Dellepiane, M.; Callieri, M.; Scopigno, R.
2016-06-01
Despite being perceived as interchangeable when properly applied, close-range photogrammetry and range imaging have both their pros and limitations that can be overcome using suitable procedures. Even if the two techniques have been frequently cross-compared, critical analysis discussing all sub-phases of a complex digitization project are quite rare. Comparisons taking into account the digitization of a cultural masterpiece, such as the Etruscan Sarcophagus of the Spouses (Figure 1) discussed in this paper, are even less common. The final 3D model of the Sarcophagus shows impressive spatial and texture resolution, in the order of tenths of millimetre for both digitization techniques, making it a large 3D digital model even though the physical size of the artwork is quite limited. The paper presents the survey of the Sarcophagus, a late 6th century BC Etruscan anthropoid Sarcophagus. Photogrammetry and laser scanning were used for its 3D digitization in two different times only few days apart from each other. The very short time available for the digitization was a crucial constraint for the surveying operations (due to constraints imposed us by the museum curators). Despite very high-resolution and detailed 3D models have been produced, a metric comparison between the two models shows intrinsic limitations of each technique that should be overcome through suitable onsite metric verification procedures as well as a proper processing workflow.
NASA Astrophysics Data System (ADS)
Seifert, Stefan; van der Lei, Gerben; van Dam, Herman T.; Schaart, Dennis R.
2013-05-01
Monolithic scintillator detectors can offer a combination of spatial resolution, energy resolution, timing performance, depth-of-interaction information, and detection efficiency that make this type of detector a promising candidate for application in clinical, time-of-flight (TOF) positron emission tomography (PET). In such detectors the scintillation light is distributed over a relatively large number of photosensor pixels and the light intensity per pixel can be relatively low. Therefore, monolithic scintillator detectors are expected to benefit from the low readout noise offered by a novel photosensor called the digital silicon photomultiplier (dSiPM). Here, we present a first experimental characterization of a TOF PET detector comprising a 24 × 24 × 10 mm3 LSO:Ce,0.2%Ca scintillator read out by a dSiPM array (DPC-6400-44-22) developed by Philips Digital Photon Counting. A spatial resolution of ˜1 mm full-width-at-half-maximum (FWHM) averaged over the entire crystal was obtained (varying from just below 1 mm FWHM in the detector center to ˜1.2 mm FWHM close to the edges). Furthermore, the bias in the position estimation at the crystal edges that is typically found in monolithic scintillators is well below 1 mm even in the corners of the crystal.
Image microarrays (IMA): Digital pathology's missing tool
Hipp, Jason; Cheng, Jerome; Pantanowitz, Liron; Hewitt, Stephen; Yagi, Yukako; Monaco, James; Madabhushi, Anant; Rodriguez-canales, Jaime; Hanson, Jeffrey; Roy-Chowdhuri, Sinchita; Filie, Armando C.; Feldman, Michael D.; Tomaszewski, John E.; Shih, Natalie NC.; Brodsky, Victor; Giaccone, Giuseppe; Emmert-Buck, Michael R.; Balis, Ulysses J.
2011-01-01
Introduction: The increasing availability of whole slide imaging (WSI) data sets (digital slides) from glass slides offers new opportunities for the development of computer-aided diagnostic (CAD) algorithms. With the all-digital pathology workflow that these data sets will enable in the near future, literally millions of digital slides will be generated and stored. Consequently, the field in general and pathologists, specifically, will need tools to help extract actionable information from this new and vast collective repository. Methods: To address this limitation, we designed and implemented a tool (dCORE) to enable the systematic capture of image tiles with constrained size and resolution that contain desired histopathologic features. Results: In this communication, we describe a user-friendly tool that will enable pathologists to mine digital slides archives to create image microarrays (IMAs). IMAs are to digital slides as tissue microarrays (TMAs) are to cell blocks. Thus, a single digital slide could be transformed into an array of hundreds to thousands of high quality digital images, with each containing key diagnostic morphologies and appropriate controls. Current manual digital image cut-and-paste methods that allow for the creation of a grid of images (such as an IMA) of matching resolutions are tedious. Conclusion: The ability to create IMAs representing hundreds to thousands of vetted morphologic features has numerous applications in education, proficiency testing, consensus case review, and research. Lastly, in a manner analogous to the way conventional TMA technology has significantly accelerated in situ studies of tissue specimens use of IMAs has similar potential to significantly accelerate CAD algorithm development. PMID:22200030
Stochastic Downscaling of Digital Elevation Models
NASA Astrophysics Data System (ADS)
Rasera, Luiz Gustavo; Mariethoz, Gregoire; Lane, Stuart N.
2016-04-01
High-resolution digital elevation models (HR-DEMs) are extremely important for the understanding of small-scale geomorphic processes in Alpine environments. In the last decade, remote sensing techniques have experienced a major technological evolution, enabling fast and precise acquisition of HR-DEMs. However, sensors designed to measure elevation data still feature different spatial resolution and coverage capabilities. Terrestrial altimetry allows the acquisition of HR-DEMs with centimeter to millimeter-level precision, but only within small spatial extents and often with dead ground problems. Conversely, satellite radiometric sensors are able to gather elevation measurements over large areas but with limited spatial resolution. In the present study, we propose an algorithm to downscale low-resolution satellite-based DEMs using topographic patterns extracted from HR-DEMs derived for example from ground-based and airborne altimetry. The method consists of a multiple-point geostatistical simulation technique able to generate high-resolution elevation data from low-resolution digital elevation models (LR-DEMs). Initially, two collocated DEMs with different spatial resolutions serve as an input to construct a database of topographic patterns, which is also used to infer the statistical relationships between the two scales. High-resolution elevation patterns are then retrieved from the database to downscale a LR-DEM through a stochastic simulation process. The output of the simulations are multiple equally probable DEMs with higher spatial resolution that also depict the large-scale geomorphic structures present in the original LR-DEM. As these multiple models reflect the uncertainty related to the downscaling, they can be employed to quantify the uncertainty of phenomena that are dependent on fine topography, such as catchment hydrological processes. The proposed methodology is illustrated for a case study in the Swiss Alps. A swissALTI3D HR-DEM (with 5 m resolution) and a SRTM-derived LR-DEM from the Western Alps are used to downscale a SRTM-based LR-DEM from the eastern part of the Alps. The results show that the method is capable of generating multiple high-resolution synthetic DEMs that reproduce the spatial structure and statistics of the original DEM.
FINDS: A fault inferring nonlinear detection system programmers manual, version 3.0
NASA Technical Reports Server (NTRS)
Lancraft, R. E.
1985-01-01
Detailed software documentation of the digital computer program FINDS (Fault Inferring Nonlinear Detection System) Version 3.0 is provided. FINDS is a highly modular and extensible computer program designed to monitor and detect sensor failures, while at the same time providing reliable state estimates. In this version of the program the FINDS methodology is used to detect, isolate, and compensate for failures in simulated avionics sensors used by the Advanced Transport Operating Systems (ATOPS) Transport System Research Vehicle (TSRV) in a Microwave Landing System (MLS) environment. It is intended that this report serve as a programmers guide to aid in the maintenance, modification, and revision of the FINDS software.
Apollo Lunar Sample Photographs: Digitizing the Moon Rock Collection
NASA Technical Reports Server (NTRS)
Lofgren, Gary E.; Todd, Nancy S.; Runco, S. K.; Stefanov, W. L.
2011-01-01
The Acquisition and Curation Office at JSC has undertaken a 4-year data restoration project effort for the lunar science community funded by the LASER program (Lunar Advanced Science and Exploration Research) to digitize photographs of the Apollo lunar rock samples and create high resolution digital images. These sample photographs are not easily accessible outside of JSC, and currently exist only on degradable film in the Curation Data Storage Facility
Integrated Real-Time Control and Imaging System for Microbiorobotics and Nanobiostructures
2016-01-11
kit with a control board and ALP 4.1 basic controller suite. The digital micromirror device is the highest resolution 16:9 aspect ratio system. This...in Figure 1, consisted of the following: (1) digital micromirror device (DMD) and controller, (2) an inverted epifluorescence microscope with a flat...accompanying control board and ALP 4.1 basic controller suite. The digital micromirror device is currently the highest commercially available
Digital micromirror device-based laser-illumination Fourier ptychographic microscopy
Kuang, Cuifang; Ma, Ye; Zhou, Renjie; Lee, Justin; Barbastathis, George; Dasari, Ramachandra R.; Yaqoob, Zahid; So, Peter T. C.
2015-01-01
We report a novel approach to Fourier ptychographic microscopy (FPM) by using a digital micromirror device (DMD) and a coherent laser source (532 nm) for generating spatially modulated sample illumination. Previously demonstrated FPM systems are all based on partially-coherent illumination, which offers limited throughput due to insufficient brightness. Our FPM employs a high power coherent laser source to enable shot-noise limited high-speed imaging. For the first time, a digital micromirror device (DMD), imaged onto the back focal plane of the illumination objective, is used to generate spatially modulated sample illumination field for ptychography. By coding the on/off states of the micromirrors, the illumination plane wave angle can be varied at speeds more than 4 kHz. A set of intensity images, resulting from different oblique illuminations, are used to numerically reconstruct one high-resolution image without obvious laser speckle. Experiments were conducted using a USAF resolution target and a fiber sample, demonstrating high-resolution imaging capability of our system. We envision that our approach, if combined with a coded-aperture compressive-sensing algorithm, will further improve the imaging speed in DMD-based FPM systems. PMID:26480361
Digital micromirror device-based laser-illumination Fourier ptychographic microscopy.
Kuang, Cuifang; Ma, Ye; Zhou, Renjie; Lee, Justin; Barbastathis, George; Dasari, Ramachandra R; Yaqoob, Zahid; So, Peter T C
2015-10-19
We report a novel approach to Fourier ptychographic microscopy (FPM) by using a digital micromirror device (DMD) and a coherent laser source (532 nm) for generating spatially modulated sample illumination. Previously demonstrated FPM systems are all based on partially-coherent illumination, which offers limited throughput due to insufficient brightness. Our FPM employs a high power coherent laser source to enable shot-noise limited high-speed imaging. For the first time, a digital micromirror device (DMD), imaged onto the back focal plane of the illumination objective, is used to generate spatially modulated sample illumination field for ptychography. By coding the on/off states of the micromirrors, the illumination plane wave angle can be varied at speeds more than 4 kHz. A set of intensity images, resulting from different oblique illuminations, are used to numerically reconstruct one high-resolution image without obvious laser speckle. Experiments were conducted using a USAF resolution target and a fiber sample, demonstrating high-resolution imaging capability of our system. We envision that our approach, if combined with a coded-aperture compressive-sensing algorithm, will further improve the imaging speed in DMD-based FPM systems.
Super-Resolution Enhancement From Multiple Overlapping Images: A Fractional Area Technique
NASA Astrophysics Data System (ADS)
Michaels, Joshua A.
With the availability of large quantities of relatively low-resolution data from several decades of space borne imaging, methods of creating an accurate, higher-resolution image from the multiple lower-resolution images (i.e. super-resolution), have been developed almost since such imagery has been around. The fractional-area super-resolution technique developed in this thesis has never before been documented. Satellite orbits, like Landsat, have a quantifiable variation, which means each image is not centered on the exact same spot more than once and the overlapping information from these multiple images may be used for super-resolution enhancement. By splitting a single initial pixel into many smaller, desired pixels, a relationship can be created between them using the ratio of the area within the initial pixel. The ideal goal for this technique is to obtain smaller pixels with exact values and no error, yielding a better potential result than those methods that yield interpolated pixel values with consequential loss of spatial resolution. A Fortran 95 program was developed to perform all calculations associated with the fractional-area super-resolution technique. The fractional areas are calculated using traditional trigonometry and coordinate geometry and Linear Algebra Package (LAPACK; Anderson et al., 1999) is used to solve for the higher-resolution pixel values. In order to demonstrate proof-of-concept, a synthetic dataset was created using the intrinsic Fortran random number generator and Adobe Illustrator CS4 (for geometry). To test the real-life application, digital pictures from a Sony DSC-S600 digital point-and-shoot camera with a tripod were taken of a large US geological map under fluorescent lighting. While the fractional-area super-resolution technique works in perfect synthetic conditions, it did not successfully produce a reasonable or consistent solution in the digital photograph enhancement test. The prohibitive amount of processing time (up to 60 days for a relatively small enhancement area) severely limits the practical usefulness of fraction-area super-resolution. Fractional-area super-resolution is very sensitive to relative input image co-registration, which must be accurate to a sub-pixel degree. However, use of this technique, if input conditions permit, could be applied as a "pinpoint" super-resolution technique. Such an application could be possible by only applying it to only very small areas with very good input image co-registration.
Fidler, Samantha; D’Orsogna, Lloyd; Irish, Ashley B.; Lewis, Joshua R.; Wong, Germaine; Lim, Wai H.
2018-01-01
Structural human leukocyte antigen (HLA) matching at the eplet level can be identified by HLAMatchmaker, which requires the entry of four-digit alleles. The aim of this study was to evaluate the agreement between eplet mismatches calculated by serological and two-digit typing methods compared to high-resolution four-digit typing. In a cohort of 264 donor/recipient pairs, the evaluation of measurement error was assessed using intra-class correlation to confirm the absolute agreement between the number of eplet mismatches at class I (HLA-A, -B, C) and II loci (HLA-DQ and -DR) calculated using serological or two-digit molecular typing compared to four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches between the HLA typing methods was also determined. Intra-class correlation coefficients between serological and four-digit molecular typing methods were 0.969 (95% confidence intervals [95% CI] 0.960–0.975) and 0.926 (95% CI 0.899–0.944), respectively; and 0.995 (95% CI 0.994–0.996) and 0.993 (95% CI 0.991–0.995), respectively between two-digit and four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches at class I and II loci was 4% and 16% for serological versus four-digit molecular typing methods, and 0% and 2% for two-digit versus four-digit molecular typing methods, respectively. In this small predominantly Caucasian population, compared with serology, there is a high level of agreement in the number of eplet mismatches calculated using two-compared to four-digit molecular HLA-typing methods, suggesting that two-digit typing may be sufficient in determining eplet mismatch load in kidney transplantation. PMID:29568344
Digital Longitudinal Tomosynthesis
NASA Astrophysics Data System (ADS)
Rimkus, Daniel Steven
1985-12-01
The purpose of this dissertation was to investigate the clinical utility of digital longitudinal tomosynthesis in radiology. By acquiring a finite group of digital images during a longitudinal tomographic exposure, and processing these images, tomographic planes, other than the fulcrum plane, can be reconstructed. This process is now termed "tomosynthesis". A prototype system utilizing this technique was developed. Both phantom and patient studies were done with this system. The phantom studies were evaluated by subjective, visual criterion and by quantitative analysis of edge sharpness and noise in the reconstructions. Two groups of patients and one volunteer were studied. The first patient group consisted of 8 patients undergoing intravenous urography (IVU). These patients had digital tomography and film tomography of the abdomen. The second patient group consisted of 4 patients with lung cancer admitted to the hospital for laser resection of endobronchial tumor. These patients had mediastinal digital tomograms to evaluate the trachea and mainstem bronchi. The knee of one volunteer was imaged by film tomography and digital tomography. The results of the phantom studies showed that the digital reconstructions accurately produced images of the desired planes. The edge sharpness of the reconstructions approached that of the acquired images. Adequate reconstructions were achieved with as few as 5 images acquired during the exposure, with the quality of the reconstructions improving as the number of images acquired increased. The IVU patients' digital studies had less contrast and spatial resolution than the film tomograms. The single renal lesion visible on the film tomograms was also visible in the digital images. The digital mediastinal studies were felt by several radiologists to be superior to a standard chest xray in evaluating the airways. The digital images of the volunteer's knee showed many of the same anatomic features as the film tomogram, but the digital images had less spatial and contrast resolution. With the equipment improvements discussed in the thesis, digital tomography may have an important role in radiology.
Meng, Xi; Nguyen, Bao D; Ridge, Clark; Shaka, A J
2009-01-01
High-dimensional (HD) NMR spectra have poorer digital resolution than low-dimensional (LD) spectra, for a fixed amount of experiment time. This has led to "reduced-dimensionality" strategies, in which several LD projections of the HD NMR spectrum are acquired, each with higher digital resolution; an approximate HD spectrum is then inferred by some means. We propose a strategy that moves in the opposite direction, by adding more time dimensions to increase the information content of the data set, even if only a very sparse time grid is used in each dimension. The full HD time-domain data can be analyzed by the filter diagonalization method (FDM), yielding very narrow resonances along all of the frequency axes, even those with sparse sampling. Integrating over the added dimensions of HD FDM NMR spectra reconstitutes LD spectra with enhanced resolution, often more quickly than direct acquisition of the LD spectrum with a larger number of grid points in each of the fewer dimensions. If the extra-dimensions do not appear in the final spectrum, and are used solely to boost information content, we propose the moniker hidden-dimension NMR. This work shows that HD peaks have unmistakable frequency signatures that can be detected as single HD objects by an appropriate algorithm, even though their patterns would be tricky for a human operator to visualize or recognize, and even if digital resolution in an HD FT spectrum is very coarse compared with natural line widths.
Meng, Xi; Nguyen, Bao D.; Ridge, Clark; Shaka, A. J.
2009-01-01
High-dimensional (HD) NMR spectra have poorer digital resolution than low-dimensional (LD) spectra, for a fixed amount of experiment time. This has led to “reduced-dimensionality” strategies, in which several LD projections of the HD NMR spectrum are acquired, each with higher digital resolution; an approximate HD spectrum is then inferred by some means. We propose a strategy that moves in the opposite direction, by adding more time dimensions to increase the information content of the data set, even if only a very sparse time grid is used in each dimension. The full HD time-domain data can be analyzed by the Filter Diagonalization Method (FDM), yielding very narrow resonances along all of the frequency axes, even those with sparse sampling. Integrating over the added dimensions of HD FDM NMR spectra reconstitutes LD spectra with enhanced resolution, often more quickly than direct acquisition of the LD spectrum with a larger number of grid points in each of the fewer dimensions. If the extra dimensions do not appear in the final spectrum, and are used solely to boost information content, we propose the moniker hidden-dimension NMR. This work shows that HD peaks have unmistakable frequency signatures that can be detected as single HD objects by an appropriate algorithm, even though their patterns would be tricky for a human operator to visualize or recognize, and even if digital resolution in an HD FT spectrum is very coarse compared with natural line widths. PMID:18926747
VGOS Operations and Geodetic Results
NASA Astrophysics Data System (ADS)
Niell, Arthur E.; Beaudoin, Christopher J.; Bolotin, Sergei; Cappallo, Roger J.; Corey, Brian E.; Gipson, John; Gordon, David; McWhirter, Russell; Ruszczyk, Chester A.; SooHoo, Jason
2014-12-01
Over the past two years the first VGOS geodetic results were obtained using the GGAO12M and Westford broadband systems that have been developed under NASA sponsorship and funding. These observations demonstrated full broadband operation, from data acquisition through correlation, delay extraction, and baseline estimation. The May 2013 24-hour session proceeded almost without human intervention in anticipation of the goal of unattended operation. A recent test observation successfully demonstrated the use of what is expected to be the operational version of the RDBE digital back end and the Mark 6 system on which the outputs of four RDBEs, each processing one RF band, were recorded on a single module at eight gigabits per second. The complex-sample VDIF data from GGAO12M and Westford were cross-correlated on the Haystack DiFX software correlator, and the instrumental delay was calculated from all of the phase calibration tones in each channel. A minimum redundancy frequency sequence (1, 2, 4, 6, 9, 13, 14, 15) was utilized to minimize the first sidelobes of the multiband delay resolution function.
LED-based near infrared sensor for cancer diagnostics
NASA Astrophysics Data System (ADS)
Bogomolov, Andrey; Ageev, Vladimir; Zabarylo, Urszula; Usenov, Iskander; Schulte, Franziska; Kirsanov, Dmitry; Belikova, Valeria; Minet, Olaf; Feliksberger, E.; Meshkovsky, I.; Artyushenko, Viacheslav
2016-03-01
Optical spectroscopic technologies are increasingly used for cancer diagnostics. Feasibility of differentiation between malignant and healthy samples of human kidney using Fluorescence, Raman, MIR and NIR spectroscopy has been recently reported . In the present work, a simplification of NIR spectroscopy method has been studied. Traditional high-resolution NIR spectrometry was replaced by an optical sensor based on a set of light-emitting diodes at selected wavelengths as light sources and a photodiode. Two prototypes of the sensor have been developed and tested using 14 in-vitro samples of seven kidney tumor patients. Statistical evaluation of results using principal component analysis and partial least-squares discriminant analysis has been performed. Despite only partial discrimination between tumor and healthy tissue achieved by the presented new technique, the results evidence benefits of LED-based near-infrared sensing used for oncological diagnostics. Publisher's Note: This paper, originally published on 4 March, 2016, was replaced with a corrected/revised version on 7 April, 2016. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance.
NASA Astrophysics Data System (ADS)
Ferraro, R.; Danzeca, S.; Brucoli, M.; Masi, A.; Brugger, M.; Dilillo, L.
2017-04-01
The need for upgrading the Total Ionizing Dose (TID) measurement resolution of the current version of the Radiation Monitoring system for the LHC complex has driven the research of new TID sensors. The sensors being developed nowadays can be defined as Systems On Chip (SOC) with both analog and digital circuitries embedded in the same silicon. A radiation tolerant TID Monitoring System (TIDMon) has been designed to allow the placement of the entire dosimeter readout electronics in very harsh environments such as calibration rooms and even in the mixed radiation field such as the one of the LHC complex. The objective of the TIDMon is to measure the effect of the TID on the new prototype of Floating Gate Dosimeter (FGDOS) without using long cables and with a reliable measurement system. This work introduces the architecture of the TIDMon, the radiation tolerance techniques applied on the controlling electronics as well as the design choices adopted for the system. Finally, results of several tests of TIDMon under different radiation environments such as gamma rays or mixed radiation field at CHARM are presented.
Semiannual progress report, April - September 1991
NASA Technical Reports Server (NTRS)
1991-01-01
Research conducted during the past year in the climate and modeling programs has concentrated on the development of appropriate atmospheric and upper ocean models, and preliminary applications of these models. Principal models are a one-dimensional radiative-convective model, a three dimensional global climate model, and an upper ocean model. Principal applications have been the study of the impact of CO2, aerosols, and the solar constant on climate. Progress was made in the 3-D model development towards physically realistic treatment of these processes. In particular, a map of soil classifications on 1 degree by 1 degree resolution has now been digitized, and soil properties have been assigned to each soil type. Using this information about soil properties, a method has been developed to simulate the hydraulic behavior of the soils of the world. This improved treatment of soil hydrology, together with the seasonally varying vegetation cover, will provide a more realistic study of the role of the terrestrial biota in climate change. A new version of the climate model was created which follows the isotopes of water and sources of water throughout the planet.
A PET detector prototype based on digital SiPMs and GAGG scintillators.
Schneider, Florian R; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I
2015-02-21
Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm(2), comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm(-3), 520 nm peak emission, 46 000 photons MeV(-1), 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm(3) were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm(3)) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with (18)F was used for tomographic tests.
A PET detector prototype based on digital SiPMs and GAGG scintillators
NASA Astrophysics Data System (ADS)
Schneider, Florian R.; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I.
2015-02-01
Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm2, comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm-3, 520 nm peak emission, 46 000 photons MeV-1, 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm3 were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm3) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with 18F was used for tomographic tests.
Prostate Cancer Screening (PDQ®)—Health Professional Version
Prostate cancer screening with the prostate-specific antigen (PSA) test or digital rectal exams has not been shown to reduce prostate cancer deaths. Get detailed information about prostate cancer screening, including potential benefits and harms, in this summary for clinicians.
TECHNICAL DESIGN NOTE: Picosecond resolution programmable delay line
NASA Astrophysics Data System (ADS)
Suchenek, Mariusz
2009-11-01
The note presents implementation of a programmable delay line for digital signals. The tested circuit has a subnanosecond delay range programmable with a resolution of picoseconds. Implementation of the circuit was based on low-cost components, easily available on the market.
Tanzania Images Highlight Improvements in Full-Resolution SRTM Africa Data
2014-09-24
A site in the Crater Highlands of Tanzania reveals the difference between NASA Shuttle Radar Topography Mission SRTM digital elevation model data as originally released in 2004 left and as now released at full resolution in 2014 right.
Digital multi-channel high resolution phase locked loop for surveillance radar systems
NASA Astrophysics Data System (ADS)
Rizk, Mohamed; Shaaban, Shawky; Abou-El-Nadar, Usama M.; Hafez, Alaa El-Din Sayed
This paper present a multi-channel, high resolution, fast lock phase locked loop (PLL) for surveillance radar applications. Phase detector based PLLs are simple to design, suffer no systematic phase error, and can run at the highest speed. Reducing loop gain can proportionally improve jitter performance, but also reduces locking time and pull-in range. The proposed system is based on digital process and control the error signal to the voltage controlled oscillator (VCO) adaptively to control its gain in order to achieve fast lock times while improving in lock jitter performance. Under certain circumstances the design also improves the frequency agility capability of the radar system. The results show a fast lock, high resolution PLL with transient time less than 10 µ sec which is suitable to radar applications.
Assessment of Required Accuracy of Digital Elevation Data for Hydrologic Modeling
NASA Technical Reports Server (NTRS)
Kenward, T.; Lettenmaier, D. P.
1997-01-01
The effect of vertical accuracy of Digital Elevation Models (DEMs) on hydrologic models is evaluated by comparing three DEMs and resulting hydrologic model predictions applied to a 7.2 sq km USDA - ARS watershed at Mahantango Creek, PA. The high resolution (5 m) DEM was resempled to a 30 m resolution using method that constrained the spatial structure of the elevations to be comparable with the USGS and SIR-C DEMs. This resulting 30 m DEM was used as the reference product for subsequent comparisons. Spatial fields of directly derived quantities, such as elevation differences, slope, and contributing area, were compared to the reference product, as were hydrologic model output fields derived using each of the three DEMs at the common 30 m spatial resolution.
Comparison of Digital Imaging Systems for Neutron Radiography
NASA Astrophysics Data System (ADS)
Pugliesi, R.; Pugliesi, Fábio; Stanojev Pereira, M. A.
2011-09-01
The characteristics of three digital imaging systems for neutron radiography purposes have been compared. Two of them make use of films, CR-39 and Kodak AA, and the third makes use of a LiF scintillator, for image registration. The irradiations were performed in the neutron radiography facility installed at the IEA-R1 nuclear research reactor of IPEN-CNEN/SP. According to the obtained results, the system based on CR-39 is the slowest to obtain an image, and the best in terms of resolution but the worse in terms of contrast. The system based on Kodak AA is faster than the prior, exhibits good resolution and contrast. The system based on the scintillator is the fastest to obtain an image, and best in terms of contrast but the worse in terms of resolution.
Real time flight simulation methodology
NASA Technical Reports Server (NTRS)
Parrish, E. A.; Cook, G.; Mcvey, E. S.
1976-01-01
An example sensitivity study is presented to demonstrate how a digital autopilot designer could make a decision on minimum sampling rate for computer specification. It consists of comparing the simulated step response of an existing analog autopilot and its associated aircraft dynamics to the digital version operating at various sampling frequencies and specifying a sampling frequency that results in an acceptable change in relative stability. In general, the zero order hold introduces phase lag which will increase overshoot and settling time. It should be noted that this solution is for substituting a digital autopilot for a continuous autopilot. A complete redesign could result in results which more closely resemble the continuous results or which conform better to original design goals.
Apollo Lunar Sample Photograph Digitization Project Update
NASA Technical Reports Server (NTRS)
Todd, N. S.; Lofgren, G. E.
2012-01-01
This is an update of the progress of a 4-year data restoration project effort funded by the LASER program to digitize photographs of the Apollo lunar rock samples and create high resolution digital images and undertaken by the Astromaterials Acquisition and Curation Office at JSC [1]. The project is currently in its last year of funding. We also provide an update on the derived products that make use of the digitized photos including the Lunar Sample Catalog and Photo Database[2], Apollo Sample data files for GoogleMoon[3].
Research on coding and decoding method for digital levels.
Tu, Li-fen; Zhong, Si-dong
2011-01-20
A new coding and decoding method for digital levels is proposed. It is based on an area-array CCD sensor and adopts mixed coding technology. By taking advantage of redundant information in a digital image signal, the contradiction that the field of view and image resolution restrict each other in a digital level measurement is overcome, and the geodetic leveling becomes easier. The experimental results demonstrate that the uncertainty of measurement is 1 mm when the measuring range is between 2 m and 100 m, which can meet practical needs.
NASA Astrophysics Data System (ADS)
de Sherbinin, A. M.; Yetman, G.; MacManus, K.; Vinay, S.
2017-12-01
The diversity of data on human settlements, infrastructure, and population continues to grow rapidly, with recent releases of data products based on a range of different remote sensing data sources as well as census and administrative data. We report here on recent improvements in data from the NASA Socioeconomic Data and Applications Center (SEDAC) and partner organizations, aimed at supporting both interdisciplinary research and real-world applications. The fourth version of SEDAC's Gridded Population of the World (GPWv4) now includes variables for age categories, gender, and urban/rural location, and has also been integrated with the Global Human Settlements (GHS) data developed by the Joint Research Centre of the European Commission to produce a GHS-POP grid for the years 1975, 1990, 2000 and 2015. Through a collaboration between Facebook's Connectivity Lab and the Center for International Earth Science Information Network (CIESIN), High Resolution Settlement Layer (HRSL) data derived from 50-cm DigitalGlobe imagery are now available for selected developing countries at 30-m resolution. SEDAC is also developing interactive mapping and analysis tools to facilitate visualization and access to these often large and complex data products. For example, SEDAC has collaborated with scientists from NASA's Goddard Space Flight Center to release the Global Man-made Impervious Surfaces & Settlement Extents from Landsat data at 30-m resolution through an innovative map interface. We also summarize recent progress in developing an international data collective that is bringing together both data developers and data users from the public and private sectors to collaborate on expanding data access and use, improving data quality and documentation, facilitating data intercomparison and integration, and sharing of resources and capabilities.
New products from the shuttle radar topography mission
Gesch, Dean B.; Farr, Tom; Slater, James; Muller, Jan-Peter; Cook, Sally
2006-01-01
Final products include elevation data resulting from a substantial editing effort by the NGA in which water bodies and coastlines were well defined and data artifacts known as spikes and wells (single pixel errors) were removed. This second version of the SRTM data set, also referred to as ‘finished’ data, represents a significant improvement over earlier versions that had nonflat water bodies, poorly defined coastlines, and numerous noise artifacts. The edited data are available at a one-arc-second resolution (approximately 30 meters) for the United States and its territories, and at a three-arc-second resolution (approximately 90 meters) for non-U.S. areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Rong; Munger, Christine; Asinas, Abdalin
2010-10-22
The crystal structure of the urease maturation protein UreE from Helicobacter pylori has been determined in its apo form at 2.1 {angstrom} resolution, bound to Cu{sup 2+} at 2.7 {angstrom} resolution, and bound to Ni{sup 2+} at 3.1 {angstrom} resolution. Apo UreE forms dimers, while the metal-bound enzymes are arranged as tetramers that consist of a dimer of dimers associated around the metal ion through coordination by His102 residues from each subunit of the tetramer. Comparison of independent subunits from different crystal forms indicates changes in the relative arrangement of the N- and C-terminal domains in response to metal binding.more » The improved ability of engineered versions of UreE containing hexahistidine sequences at either the N-terminal or C-terminal end to provide Ni{sup 2+} for the final metal sink (urease) is eliminated in the H102A version. Therefore, the ability of the improved Ni{sup 2+}-binding versions to deliver more nickel is likely an effect of an increased local concentration of metal ions that can rapidly replenish transferred ions bound to His102.« less
NASA Astrophysics Data System (ADS)
Nakhostin, M.; Hitomi, K.
2012-05-01
The energy resolution of thallium bromide (TlBr) detectors is significantly limited by charge-trapping effect and pulse ballistic deficit, caused by the slow charge collection time. A digital pulse processing algorithm has been developed aiming to compensate for charge-trapping effect, while minimizing pulse ballistic deficit. The algorithm is examined using a 1 mm thick TlBr detector and an excellent energy resolution of 3.37% at 662 keV is achieved at room temperature. The pulse processing algorithms are presented in recursive form, suitable for real-time implementations.
Digital filtering of plume emission spectra
NASA Technical Reports Server (NTRS)
Madzsar, George C.
1990-01-01
Fourier transformation and digital filtering techniques were used to separate the superpositioned spectral phenomena observed in the exhaust plumes of liquid propellant rocket engines. Space shuttle main engine (SSME) spectral data were used to show that extraction of spectral lines in the spatial frequency domain does not introduce error, and extraction of the background continuum introduces only minimal error. Error introduced during band extraction could not be quantified due to poor spectrometer resolution. Based on the atomic and molecular species found in the SSME plume, it was determined that spectrometer resolution must be 0.03 nm for SSME plume spectral monitoring.
NASA Astrophysics Data System (ADS)
Suzuki, Yuki; Fung, George S. K.; Shen, Zeyang; Otake, Yoshito; Lee, Okkyun; Ciuffo, Luisa; Ashikaga, Hiroshi; Sato, Yoshinobu; Taguchi, Katsuyuki
2017-03-01
Cardiac motion (or functional) analysis has shown promise not only for non-invasive diagnosis of cardiovascular diseases but also for prediction of cardiac future events. Current imaging modalities has limitations that could degrade the accuracy of the analysis indices. In this paper, we present a projection-based motion estimation method for x-ray CT that estimates cardiac motion with high spatio-temporal resolution using projection data and a reference 3D volume image. The experiment using a synthesized digital phantom showed promising results for motion analysis.
The effects of gray scale image processing on digital mammography interpretation performance.
Cole, Elodia B; Pisano, Etta D; Zeng, Donglin; Muller, Keith; Aylward, Stephen R; Park, Sungwook; Kuzmiak, Cherie; Koomen, Marcia; Pavic, Dag; Walsh, Ruth; Baker, Jay; Gimenez, Edgardo I; Freimanis, Rita
2005-05-01
To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and conventional screen-film mammograms of the same patients were interpreted by nine radiologists. The raw digital data were processed with each of three different image-processing algorithms creating three presentations-manufacturer's default (applied and laser printed to film by each of the manufacturers), MUSICA, and PLAHE-were presented in soft copy display. There were three radiologists per presentation. Area under the receiver operating characteristic curve for GE digital mass cases was worse than screen-film for all digital presentations. The area under the receiver operating characteristic for Trex digital mass cases was better, but only with images processed with the manufacturer's default algorithm. Sensitivity for GE digital mass cases was worse than screen film for all digital presentations. Specificity for Fischer digital calcifications cases was worse than screen film for images processed in default and PLAHE algorithms. Specificity for Trex digital calcifications cases was worse than screen film for images processed with MUSICA. Specific image-processing algorithms may be necessary for optimal presentation for interpretation based on machine and lesion type.
Geologic and Mineral Resource Map of Afghanistan
Doebrich, Jeff L.; Wahl, Ronald R.; With Contributions by Ludington, Stephen D.; Chirico, Peter G.; Wandrey, Craig J.; Bohannon, Robert G.; Orris, Greta J.; Bliss, James D.; Wasy, Abdul; Younusi, Mohammad O.
2006-01-01
Data Summary The geologic and mineral resource information shown on this map is derived from digitization of the original data from Abdullah and Chmyriov (1977) and Abdullah and others (1977). The U.S. Geological Survey (USGS) has made no attempt to modify original geologic map-unit boundaries and faults as presented in Abdullah and Chmyriov (1977); however, modifications to map-unit symbology, and minor modifications to map-unit descriptions, have been made to clarify lithostratigraphy and to modernize terminology. Labeling of map units has not been attempted where they are small or narrow, in order to maintain legibility and to preserve the map's utility in illustrating regional geologic and structural relations. Users are encouraged to refer to the series of USGS/AGS (Afghan Geological Survey) 1:250,000-scale geologic quadrangle maps of Afghanistan that are being released concurrently as open-file reports. The classification of mineral deposit types is based on the authors' interpretation of existing descriptive information (Abdullah and others, 1977; Bowersox and Chamberlin, 1995; Orris and Bliss, 2002) and on limited field investigations by the authors. Deposit-type nomenclature used for nonfuel minerals is modified from published USGS deposit-model classifications, as compiled in Stoeser and Heran (2000). New petroleum localities are based on research of archival data by the authors. The shaded-relief base is derived from Shuttle Radar Topography Mission (SRTM) digital elevation model (DEM) data having 85-meter resolution. Gaps in the original SRTM DEM dataset were filled with data digitized from contours on 1:200,000-scale Soviet General Staff Sheets (1978-1997). The marginal extent of geologic units corresponds to the position of the international boundary as defined by Abdullah and Chmyriov (1977), and the international boundary as shown on this map was acquired from the Afghanistan Information Management Service (AIMS) Web site (http://www.aims.org.af) in September 2005. Non-coincidence of these boundaries is due to differences in the respective data sources and to inexact registration of the geologic data to the DEM base. Province boundaries, province capital locations, and political names were also acquired from the AIMS Web site in September 2005. The AIMS data were originally derived from maps produced by the Afghanistan Geodesy and Cartography Head Office (AGCHO). Version 2 differs from Version 1 in that (1) map units are colored according to the color scheme of the Commission for the Geological Map of the World (CGMW) (http://www.ccgm.org), (2) the minerals database has been updated, and (3) all data presented on the map are also available in GIS format.
Naivar, Mark A.; Wilder, Mark E.; Habbersett, Robert C.; Woods, Travis A.; Sebba, David S.; Nolan, John P.; Graves, Steven W.
2014-01-01
Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers. PMID:19852060
Naivar, Mark A; Wilder, Mark E; Habbersett, Robert C; Woods, Travis A; Sebba, David S; Nolan, John P; Graves, Steven W
2009-12-01
Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD-based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers.
Existing methods for improving the accuracy of digital-to-analog converters
NASA Astrophysics Data System (ADS)
Eielsen, Arnfinn A.; Fleming, Andrew J.
2017-09-01
The performance of digital-to-analog converters is principally limited by errors in the output voltage levels. Such errors are known as element mismatch and are quantified by the integral non-linearity. Element mismatch limits the achievable accuracy and resolution in high-precision applications as it causes gain and offset errors, as well as harmonic distortion. In this article, five existing methods for mitigating the effects of element mismatch are compared: physical level calibration, dynamic element matching, noise-shaping with digital calibration, large periodic high-frequency dithering, and large stochastic high-pass dithering. These methods are suitable for improving accuracy when using digital-to-analog converters that use multiple discrete output levels to reconstruct time-varying signals. The methods improve linearity and therefore reduce harmonic distortion and can be retrofitted to existing systems with minor hardware variations. The performance of each method is compared theoretically and confirmed by simulations and experiments. Experimental results demonstrate that three of the five methods provide significant improvements in the resolution and accuracy when applied to a general-purpose digital-to-analog converter. As such, these methods can directly improve performance in a wide range of applications including nanopositioning, metrology, and optics.
NASA Astrophysics Data System (ADS)
Dukic, Maja; Todorov, Vencislav; Andany, Santiago; Nievergelt, Adrian P.; Yang, Chen; Hosseini, Nahid; Fantner, Georg E.
2017-12-01
Nearly all scanning probe microscopes (SPMs) contain a feedback controller, which is used to move the scanner in the direction of the z-axis in order to maintain a constant setpoint based on the tip-sample interaction. The most frequently used feedback controller in SPMs is the proportional-integral (PI) controller. The bandwidth of the PI controller presents one of the speed limiting factors in high-speed SPMs, where higher bandwidths enable faster scanning speeds and higher imaging resolution. Most SPM systems use digital signal processor-based PI feedback controllers, which require analog-to-digital and digital-to-analog converters. These converters introduce additional feedback delays which limit the achievable imaging speed and resolution. In this paper, we present a digitally controlled analog proportional-integral-derivative (PID) controller. The controller implementation allows tunability of the PID gains over a large amplification and frequency range, while also providing precise control of the system and reproducibility of the gain parameters. By using the analog PID controller, we were able to perform successful atomic force microscopy imaging of a standard silicon calibration grating at line rates up to several kHz.
Dukic, Maja; Todorov, Vencislav; Andany, Santiago; Nievergelt, Adrian P; Yang, Chen; Hosseini, Nahid; Fantner, Georg E
2017-12-01
Nearly all scanning probe microscopes (SPMs) contain a feedback controller, which is used to move the scanner in the direction of the z-axis in order to maintain a constant setpoint based on the tip-sample interaction. The most frequently used feedback controller in SPMs is the proportional-integral (PI) controller. The bandwidth of the PI controller presents one of the speed limiting factors in high-speed SPMs, where higher bandwidths enable faster scanning speeds and higher imaging resolution. Most SPM systems use digital signal processor-based PI feedback controllers, which require analog-to-digital and digital-to-analog converters. These converters introduce additional feedback delays which limit the achievable imaging speed and resolution. In this paper, we present a digitally controlled analog proportional-integral-derivative (PID) controller. The controller implementation allows tunability of the PID gains over a large amplification and frequency range, while also providing precise control of the system and reproducibility of the gain parameters. By using the analog PID controller, we were able to perform successful atomic force microscopy imaging of a standard silicon calibration grating at line rates up to several kHz.