Sample records for resolve diagnostic problems

  1. Component-Level Electronic-Assembly Repair (CLEAR) Analysis of the Problem Reporting and Corrective Action (PRACA) Database of the International Space Station On-Orbit Electrical Systems

    NASA Technical Reports Server (NTRS)

    Oeftering, Richard C.; Bradish, Martin A.; Juergens, Jeffrey R.; Lewis, Michael J.

    2011-01-01

    The NASA Constellation Program is investigating and developing technologies to support human exploration of the Moon and Mars. The Component-Level Electronic-Assembly Repair (CLEAR) task is part of the Supportability Project managed by the Exploration Technology Development Program. CLEAR is aimed at enabling a flight crew to diagnose and repair electronic circuits in space yet minimize logistics spares, equipment, and crew time and training. For insight into actual space repair needs, in early 2008 the project examined the operational experience of the International Space Station (ISS) program. CLEAR examined the ISS on-orbit Problem Reporting and Corrective Action database for electrical and electronic system problems. The ISS has higher than predicted reliability yet, as expected, it has persistent problems. A goal was to identify which on-orbit electrical problems could be resolved by a component-level replacement. A further goal was to identify problems that could benefit from the additional diagnostic and test capability that a component-level repair capability could provide. The study indicated that many problems stem from a small set of root causes that also represent distinct component problems. The study also determined that there are certain recurring problems where the current telemetry instrumentation and built-in tests are unable to completely resolve the problem. As a result, the root cause is listed as unknown. Overall, roughly 42 percent of on-orbit electrical problems on ISS could be addressed with a component-level repair. Furthermore, 63 percent of on-orbit electrical problems on ISS could benefit from additional external diagnostic and test capability. These results indicate that in situ component-level repair in combination with diagnostic and test capability can be expected to increase system availability and reduce logistics. The CLEAR approach can increase the flight crew s ability to act decisively to resolve problems while reducing dependency on Earth-supplied logistics for future Constellation Program missions.

  2. The "Shopping" Behavior of Parents of Mentally Retarded Children: The Professional Person's Role

    ERIC Educational Resources Information Center

    Anderson, Kathryn A.

    1971-01-01

    Discussed is the role of the professional in preventing or stopping diagnostic and therapeutic shopping (repeated visits to the same or different professionals without resolution of a resolvable problem), with emphasis on the initial informing interview. (KW)

  3. Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

    NASA Technical Reports Server (NTRS)

    Nguyen, Quang-Viet; Fischer, David G.; Kojima, Jun

    2011-01-01

    Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

  4. Impact of time-resolved MRA on diagnostic accuracy in patients with symptomatic peripheral artery disease of the calf station.

    PubMed

    Hansmann, Jan; Michaely, Henrik J; Morelli, John N; Diehl, Steffen J; Meyer, Mathias; Schoenberg, Stefan O; Attenberger, Ulrike I

    2013-12-01

    The purpose of this article is to evaluate the added diagnostic accuracy of time-resolved MR angiography (MRA) of the calves compared with continuous-table-movement MRA in patients with symptomatic lower extremity peripheral artery disease (PAD) using digital subtraction angiography (DSA) correlation. Eighty-four consecutive patients with symptomatic PAD underwent a low-dose 3-T MRA protocol, consisting of continuous-table-movement MRA, acquired from the diaphragm to the calves, and an additional time-resolved MRA of the calves; 0.1 mmol/kg body weight (bw) of contrast material was used (0.07 mmol/kg bw for continuous-table-movement MRA and 0.03 mmol/kg bw for time-resolved MRA). Two radiologists rated image quality on a 4-point scale and stenosis degree on a 3-point scale. An additional assessment determined the degree of venous contamination and whether time-resolved MRA improved diagnostic confidence. The accuracy of stenosis gradation with continuous-table-movement and time-resolved MRA was compared with that of DSA as a correlation. Overall diagnostic accuracy was calculated for continuous-table-movement and time-resolved MRA. Median image quality was rated as good for 578 vessel segments with continuous-table-movement MRA and as excellent for 565 vessel segments with time-resolved MRA. Interreader agreement was excellent (κ = 0.80-0.84). Venous contamination interfered with diagnosis in more than 60% of continuous-table-movement MRA examinations. The degree of stenosis was assessed for 340 vessel segments. The diagnostic accuracies (continuous-table-movement MRA/time-resolved MRA) combined for the readers were obtained for the tibioperoneal trunk (84%/93%), anterior tibial (69%/87%), posterior tibial (85%/91%), and peroneal (67%/81%) arteries. The addition of time-resolved MRA improved diagnostic confidence in 69% of examinations. The addition of time-resolved MRA at the calf station improves diagnostic accuracy over continuous-table-movement MRA alone in symptomatic patients with PAD.

  5. Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA.

    PubMed

    Vogt, Florian M; Theysohn, Jens M; Michna, Dariusz; Hunold, Peter; Neudorf, Ulrich; Kinner, Sonja; Barkhausen, Jörg; Quick, Harald H

    2013-09-01

    To evaluate time-resolved interleaved stochastic trajectories (TWIST) contrast-enhanced 4D magnetic resonance angiography (MRA) and compare it with 3D FLASH MRA in patients with congenital heart and vessel anomalies. Twenty-six patients with congenital heart and vessel anomalies underwent contrast-enhanced MRA with both 3D FLASH and 4D TWIST MRA. Images were subjectively evaluated regarding total image quality, artefacts, diagnostic value and added diagnostic value of 4D dynamic imaging. Quantitative comparison included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness measurements. Three-dimensional FLASH MRA was judged to be significantly better in terms of image quality (4.0 ± 0.6 vs 3.4 ± 0.6, P < 0.05) and artefacts (3.8 ± 0.4 vs 3.3 ± 0.5, P < 0.05); no difference in diagnostic value was found (4.2 ± 0.4 vs 4.0 ± 0.4); important additional functional information was found in 21/26 patients. SNR and CNR were higher in the pulmonary trunk in 4D TWIST, but slightly higher in the systemic arteries in 3D FLASH. No difference in vessel sharpness delineation was found. Although image quality was inferior compared with 3D FLASH MRA, 4D TWIST MRA yields robust images and added diagnostic value through dynamic acquisition was found. Thus, 4D TWIST MRA is an attractive alternative to 3D FLASH MRA. • New magnetic resonance angiography (MRA) techniques are increasingly introduced for congenital cardiovascular problems. • Time-resolved angiography with interleaved stochastic trajectories (TWIST) is an example. • Four-dimensional TWIST MRA provided inferior image quality compared to 3D FLASH MRA but without significant difference in vessel sharpness. • Four-dimensional TWIST MRA gave added diagnostic value.

  6. Modification of the laser triangulation method for measuring the thickness of optical layers

    NASA Astrophysics Data System (ADS)

    Khramov, V. N.; Adamov, A. A.

    2018-04-01

    The problem of determining the thickness of thin films by the method of laser triangulation is considered. An expression is derived for the film thickness and the distance between the focused beams on the photo detector. The possibility of applying the chosen method for measuring thickness is in the range [0.1; 1] mm. We could resolve 2 individual light marks for a minimum film thickness of 0.23 mm. We resolved with the help of computer processing of photos with a resolution of 0.10 mm. The obtained results can be used in ophthalmology for express diagnostics during surgical operations on the corneal layer.

  7. To what do psychiatric diagnoses refer? A two-dimensional semantic analysis of diagnostic terms

    PubMed Central

    Maung, Hane Htut

    2016-01-01

    In somatic medicine, diagnostic terms often refer to the disease processes that are the causes of patients' symptoms. The language used in some clinical textbooks and health information resources suggests that this is also sometimes assumed to be the case with diagnoses in psychiatry. However, this seems to be in tension with the ways in which psychiatric diagnoses are defined in diagnostic manuals, according to which they refer solely to clusters of symptoms. This paper explores how theories of reference in the philosophy of language can help to resolve this tension. After the evaluation of descriptive and causal theories of reference, I put forward a conceptual framework based on two-dimensional semantics that allows the causal analysis of diagnostic terms in psychiatry, while taking seriously their descriptive definitions in diagnostic manuals. While the framework is presented as a solution to a problem regarding the semantics of psychiatric diagnoses, it can also accommodate the analysis of diagnostic terms in other medical disciplines. PMID:26580354

  8. Pinned, optically aligned diagnostic dock for use on the Z facility.

    PubMed

    Gomez, M R; Rochau, G A; Bailey, J E; Dunham, G S; Kernaghan, M D; Gard, P; Robertson, G K; Owen, A C; Argo, J W; Nielsen, D S; Lake, P W

    2012-10-01

    The pinned optically aligned diagnostic dock (PODD) is a multi-configuration diagnostic platform designed to measure x-ray emission on the Z facility. The PODD houses two plasma emission acquisition (PEA) systems, which are aligned with a set of precision machined pins. The PEA systems are modular, allowing a single diagnostic housing to support several different diagnostics. The PEA configurations fielded to date include both time-resolved and time-integrated, 1D spatially resolving, elliptical crystal spectrometers, and time-integrated, 1D spatially resolving, convex crystal spectrometers. Additional proposed configurations include time-resolved, monochromatic mirrored pinhole imagers and arrays of filtered x-ray diodes, diamond photo-conducting diode detectors, and bolometers. The versatility of the PODD system will allow the diagnostic configuration of the Z facility to be changed without significantly adding to the turn-around time of the machine. Additionally, the PODD has been designed to allow instrument setup to be completed entirely off-line, leaving only a refined alignment process to be performed just prior to a shot, which is a significant improvement over the instrument the PODD replaces. Example data collected with the PODD are presented.

  9. Stability in the drinking habits of older problem-drinkers recruited from nontreatment settings.

    PubMed

    Walton, M A; Mudd, S A; Blow, F C; Chermack, S T; Gomberg, E S

    2000-03-01

    Few prospective studies have examined older problem-drinkers not currently in treatment to determine the stability in alcohol problems over time. Seventy-eight currently drinking, older adults meeting a diagnosis of alcohol abuse or dependence were recruited via advertising to complete a health interview; 48 were reinterviewed approximately 3 years later. Participants were categorized based on alcohol consumption (risk) and alcohol-related diagnostic symptoms (problem) at baseline and follow-up. At follow-up, few older adults (11.4%) were resolved using both risk and problem criteria. Alcohol risk/problem groups were not significantly stable between baseline and follow-up. Health problems was the most common reason for changing drinking habits. Average and maximum consumption at baseline and follow-up were significant markers of follow-up risk group and follow-up alcohol-related consequences, respectively, with maximum consumption being more robust. The course of alcohol problems among older adults fluctuates over time, and heavy drinking appears to be the best indicator of problem continuation.

  10. Sparsity-based super-resolved coherent diffraction imaging of one-dimensional objects.

    PubMed

    Sidorenko, Pavel; Kfir, Ofer; Shechtman, Yoav; Fleischer, Avner; Eldar, Yonina C; Segev, Mordechai; Cohen, Oren

    2015-09-08

    Phase-retrieval problems of one-dimensional (1D) signals are known to suffer from ambiguity that hampers their recovery from measurements of their Fourier magnitude, even when their support (a region that confines the signal) is known. Here we demonstrate sparsity-based coherent diffraction imaging of 1D objects using extreme-ultraviolet radiation produced from high harmonic generation. Using sparsity as prior information removes the ambiguity in many cases and enhances the resolution beyond the physical limit of the microscope. Our approach may be used in a variety of problems, such as diagnostics of defects in microelectronic chips. Importantly, this is the first demonstration of sparsity-based 1D phase retrieval from actual experiments, hence it paves the way for greatly improving the performance of Fourier-based measurement systems where 1D signals are inherent, such as diagnostics of ultrashort laser pulses, deciphering the complex time-dependent response functions (for example, time-dependent permittivity and permeability) from spectral measurements and vice versa.

  11. Resolving complex fibre architecture by means of sparse spherical deconvolution in the presence of isotropic diffusion

    NASA Astrophysics Data System (ADS)

    Zhou, Q.; Michailovich, O.; Rathi, Y.

    2014-03-01

    High angular resolution diffusion imaging (HARDI) improves upon more traditional diffusion tensor imaging (DTI) in its ability to resolve the orientations of crossing and branching neural fibre tracts. The HARDI signals are measured over a spherical shell in q-space, and are usually used as an input to q-ball imaging (QBI) which allows estimation of the diffusion orientation distribution functions (ODFs) associated with a given region-of interest. Unfortunately, the partial nature of single-shell sampling imposes limits on the estimation accuracy. As a result, the recovered ODFs may not possess sufficient resolution to reveal the orientations of fibre tracts which cross each other at acute angles. A possible solution to the problem of limited resolution of QBI is provided by means of spherical deconvolution, a particular instance of which is sparse deconvolution. However, while capable of yielding high-resolution reconstructions over spacial locations corresponding to white matter, such methods tend to become unstable when applied to anatomical regions with a substantial content of isotropic diffusion. To resolve this problem, a new deconvolution approach is proposed in this paper. Apart from being uniformly stable across the whole brain, the proposed method allows one to quantify the isotropic component of cerebral diffusion, which is known to be a useful diagnostic measure by itself.

  12. Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility.

    PubMed

    Ross, J S; Datte, P; Divol, L; Galbraith, J; Froula, D H; Glenzer, S H; Hatch, B; Katz, J; Kilkenny, J; Landen, O; Manuel, A M; Molander, W; Montgomery, D S; Moody, J D; Swadling, G; Weaver, J

    2016-11-01

    An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ 0 = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10 20 cm -3 while a 3ω probe will be used for plasma densities of ∼1 × 10 19 cm -3 . The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).

  13. Computed tomography in the evaluation of Crohn disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, H.I.; Gore, R.M.; Margulis, A.R.

    1983-02-01

    The abdominal and pelvic computed tomographic examinations in 28 patients with Crohn disease were analyzed and correlated with conventional barium studies, sinograms, and surgical findings. Mucosal abnormalities such as aphthous lesions, pseudopolyps, and ulcerations were only imaged by conventional techniques. Computed tomography proved superior in demonstrating the mural, serosal, and mesenteric abnormalities such as bowel wall thickening (82%), fibrofatty proliferation of mesenteric fat (39%), mesenteric abscess (25%), inflammatory reaction of the mesentery (14%), and mesenteric lymphadenopathy (18%). Computed tomography was most useful clinically in defining the nature of mass effects, separation, or displacement of small bowel segments seen on smallmore » bowel series. Although conventional barium studies remain the initial diagnostic procedure in evaluating Crohn disease, computed tomography can be a useful adjunct in resolving difficult clinical and radiologic diagnostic problems.« less

  14. Large biases in regression-based constituent flux estimates: causes and diagnostic tools

    USGS Publications Warehouse

    Hirsch, Robert M.

    2014-01-01

    It has been documented in the literature that, in some cases, widely used regression-based models can produce severely biased estimates of long-term mean river fluxes of various constituents. These models, estimated using sample values of concentration, discharge, and date, are used to compute estimated fluxes for a multiyear period at a daily time step. This study compares results of the LOADEST seven-parameter model, LOADEST five-parameter model, and the Weighted Regressions on Time, Discharge, and Season (WRTDS) model using subsampling of six very large datasets to better understand this bias problem. This analysis considers sample datasets for dissolved nitrate and total phosphorus. The results show that LOADEST-7 and LOADEST-5, although they often produce very nearly unbiased results, can produce highly biased results. This study identifies three conditions that can give rise to these severe biases: (1) lack of fit of the log of concentration vs. log discharge relationship, (2) substantial differences in the shape of this relationship across seasons, and (3) severely heteroscedastic residuals. The WRTDS model is more resistant to the bias problem than the LOADEST models but is not immune to them. Understanding the causes of the bias problem is crucial to selecting an appropriate method for flux computations. Diagnostic tools for identifying the potential for bias problems are introduced, and strategies for resolving bias problems are described.

  15. Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

    DOE PAGES

    Ross, J. S.; Datte, P.; Divol, L.; ...

    2016-07-28

    An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. Here, we report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ 0 = 210 nm) will be used to Thomson scatter from electron plasma densities of ~5 × 10 20more » cm -3 while a 3ω probe will be used for plasma densities of ~1 × 10 19 cm -3. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).« less

  16. Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, J. S., E-mail: ross36@llnl.gov; Datte, P.; Divol, L.

    2016-11-15

    An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ{sub 0} = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10{sup 20} cm{supmore » −3} while a 3ω probe will be used for plasma densities of ∼1 × 10{sup 19} cm{sup −3}. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).« less

  17. Attitude Determination and Control System (ADCS) and Maintenance and Diagnostic System (MDS): A maintenance and diagnostic system for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Toms, David; Hadden, George D.; Harrington, Jim

    1990-01-01

    The Maintenance and Diagnostic System (MDS) that is being developed at Honeywell to enhance the Fault Detection Isolation and Recovery system (FDIR) for the Attitude Determination and Control System on Space Station Freedom is described. The MDS demonstrates ways that AI-based techniques can be used to improve the maintainability and safety of the Station by helping to resolve fault anomalies that cannot be fully determined by built-in-test, by providing predictive maintenance capabilities, and by providing expert maintenance assistance. The MDS will address the problems associated with reasoning about dynamic, continuous information versus only about static data, the concerns of porting software based on AI techniques to embedded targets, and the difficulties associated with real-time response. An initial prototype was built of the MDS. The prototype executes on Sun and IBM PS/2 hardware and is implemented in the Common Lisp; further work will evaluate its functionality and develop mechanisms to port the code to Ada.

  18. Under the umbrella

    PubMed Central

    Müller, Kai W.

    2017-01-01

    The inclusion of Internet Gaming Disorder as a preliminary diagnosis subsumed in Section III of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) has provoked mixed reactions. On the one hand, it has been appreciated as an important sign stressing the negative health-related impact of that disorder. Likewise, the definition of diagnostic criteria helps scientists and clinicians to refer to mandatory indicators associated with a health problem. On the other hand, it has been objected that this new diagnosis bears the danger of pathologizing normal behaviors that are a feature of healthy recreational activity for many people. However, the existence of diagnostic criteria is meant to avoid this danger. This emphasizes the necessity of being able to refer to as accurate defined criteria as possible. In its current version, the DSM criteria display not only strengths but also ambiguities. Both types will be discussed and necessary ideas to resolve those ambiguities will be presented for further research. PMID:28301966

  19. Persistent problems with the Munchausen syndrome by proxy label.

    PubMed

    Pankratz, Loren

    2006-01-01

    After nearly 30 years of clinical and legal experience, the definition of Munchausen syndrome by proxy remains controversial. As a result, mothers who present the problems of their children in ways perceived as unusual or problematic have become entangled in legal battles that should have been resolved clinically. Re-labeling the disorder as Pediatric Condition Falsification misdirects the focus onto mistakes and misunderstandings while avoiding the more crucial issue of intentions. Experts have enflamed the fears of harm by confusing warning signs with diagnostic signs and by citing retrospective studies instead of the more optimistic outcome studies. Accused mothers need the support of multidisciplinary teams but are often forced into contentious struggles with legal professionals and child protection services.

  20. Sensitivity Analysis and Requirements for Temporally and Spatially Resolved Thermometry Using Neutron Resonance Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fernandez, Juan Carlos; Barnes, Cris William; Mocko, Michael Jeffrey

    This report is intended to examine the use of neutron resonance spectroscopy (NRS) to make time- dependent and spatially-resolved temperature measurements of materials in extreme conditions. Specifically, the sensitivities of the temperature estimate on neutron-beam and diagnostic parameters is examined. Based on that examination, requirements are set on a pulsed neutron-source and diagnostics to make a meaningful measurement.

  1. Diagnostics of vector magnetic fields

    NASA Technical Reports Server (NTRS)

    Stenflo, J. O.

    1985-01-01

    It is shown that the vector magnetic fields derived from observations with a filter magnetograph will be severely distorted if the spatially unresolved magnetic structure is not properly accounted for. Thus the apparent vector field will appear much more horizontal than it really is, but this distortion is strongly dependent on the area factor and the temperature line weakenings. As the available fluxtube models are not sufficiently well determined, it is not possible to correct the filter magnetograph observations for these effects in a reliable way, although a crude correction is of course much better than no correction at all. The solution to this diagnostic problem is to observe simultaneously in suitable combinations of spectral lines, and/or use Stokes line profiles recorded with very high spectral resolution. The diagnostic power of using a Fourier transform spectrometer for polarimetry is shown and some results from I and V spectra are illustrated. The line asymmetries caused by mass motions inside the fluxtubes adds an extra complication to the diagnostic problem, in particular as there are indications that the motions are nonstationary in nature. The temperature structure appears to be a function of fluxtube diameter, as a clear difference between plage and network fluxtubes was revealed. The divergence of the magnetic field with height plays an essential role in the explanation of the Stokes V asymmetries (in combination with the mass motions). A self consistent treatment of the subarcsec field geometry may be required to allow an accurate derivation of the spatially averaged vector magnetic field from spectrally resolved data.

  2. Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite.

    PubMed

    Yang, Pengfei; Niu, Kai; Wu, Yijing; Struffert, Tobias; Dorfler, Arnd; Schafer, Sebastian; Royalty, Kevin; Strother, Charles; Chen, Guang-Hong

    2015-12-01

    Multimodal imaging using cone beam C-arm computed tomography (CT) may shorten the delay from ictus to revascularization for acute ischemic stroke patients with a large vessel occlusion. Largely because of limited temporal resolution, reconstruction of time-resolved CT angiography (CTA) from these systems has not yielded satisfactory results. We evaluated the image quality and diagnostic value of time-resolved C-arm CTA reconstructed using novel image processing algorithms. Studies were done under an Institutional Review Board approved protocol. Postprocessing of data from 21 C-arm CT dynamic perfusion acquisitions from 17 patients with acute ischemic stroke were done to derive time-resolved C-arm CTA images. Two observers independently evaluated image quality and diagnostic content for each case. ICC and receiver-operating characteristic analysis were performed to evaluate interobserver agreement and diagnostic value of this novel imaging modality. Time-resolved C-arm CTA images were successfully generated from 20 data sets (95.2%, 20/21). Two observers agreed well that the image quality for large cerebral arteries was good but was more limited for small cerebral arteries (distal to M1, A1, and P1). receiver-operating characteristic curves demonstrated excellent diagnostic value for detecting large vessel occlusions (area under the curve=0.987-1). Time-resolved CTAs derived from C-arm CT perfusion acquisitions provide high quality images that allowed accurate diagnosis of large vessel occlusions. Although image quality of smaller arteries in this study was not optimal ongoing modifications of the postprocessing algorithm will likely remove this limitation. Adding time-resolved C-arm CTAs to the capabilities of the angiography suite further enhances its suitability as a one-stop shop for care for patients with acute ischemic stroke. © 2015 American Heart Association, Inc.

  3. 48 CFR 2929.101 - Resolving tax problems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Resolving tax problems. 2929.101 Section 2929.101 Federal Acquisition Regulations System DEPARTMENT OF LABOR GENERAL CONTRACTING REQUIREMENTS TAXES General 2929.101 Resolving tax problems. Contract tax problems or questions...

  4. 48 CFR 29.101 - Resolving tax problems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (d) Before purchasing goods or services from a foreign source, the contracting officer should consult... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Resolving tax problems. 29... CONTRACTING REQUIREMENTS TAXES General 29.101 Resolving tax problems. (a) Contract tax problems are...

  5. Diagnostic and Treatment Reproducibility of Cervical Intraepithelial Neoplasia / Squamous Intraepithelial Lesion and Factors Affecting the Diagnosis.

    PubMed

    Sağlam, Arzu; Usubütün, Alp; Dolgun, Anıl; Mutter, George L; Salman, M Coşkun; Kurtulan, Olcay; Akyol, Aytekin; Özkan, Eylem Akar; Baykara, Sema; Bülbül, Dilek; Calay, Zerrin; Eren, Funda; Gümürdülü, Derya; Haberal, Nihan; Ilvan, Şennur; Karaveli, Şeyda; Koyuncuoğlu, Meral; Müezzinoğlu, Bahar; Müftüoğlu, Kamil Hakan; Özen, Özlem; Özdemir, Necmettin; Peştereli, Elif; Ulukuş, Çağnur; Zekioğlu, Osman

    2017-01-01

    Inter-observer differences in the diagnosis of HPV related cervical lesions are problematic and response of gynecologists to these diagnostic entities is non-standardized. This study evaluated the diagnostic reproducibility of "cervical intraepithelial neoplasia" (CIN) and "squamous intraepithelial lesion" (SIL) diagnoses. 19 pathologists evaluated 66 cases once using H&E slides and once with immunohistochemical studies (p16, Ki-67 and Pro-ExC). Management response to diagnoses was evaluated amongst 12 gynecologists. Pathologists and gynecologists were also given a questionnaire about how additional information like smear results and age modify diagnosis and management. We show moderate interobserver diagnostic reproducibility amongst pathologists. The overall kappa value was 0.50 and 0.59 using the CIN and SIL classifications respectively. Impact of immunohistochemical evaluation on interpretation of cases differed and there was lack of statistically significant improvement of interobserver diagnostic reproducibility with the addition of immunohistochemistry. We saw that choice of treatment methods amongst gynecologists varied and overall concordance was only fair to moderate. The CIN2 diagnostic category was seen to have the lowest percentage agreement amongst both pathologists and gynecologists. We showed that pathologists had diagnostic "styles" and gynecologists had management "styles". In summary each pathologist had different diagnostic tendencies which were affected not only by histopathology and marker studies, but also by the patient management tendencies of the gynecologist that the pathologist worked with. The two-tiered modified Bethesda system improved diagnostic agreement. We concluded that immunohistochemistry should be used only to resolve problems in select cases and not for every case.

  6. Strategic bombers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-07-01

    This paper reports on the questions: should Congress provide more funds for the Air Force's current plan---the CORE program---to upgrade the B-1B defense avionics system In GAO's view, more testing of the system is not necessary to determine whether to implement the CORE program. Flight testing has shown that the CORE modifications would provide similar operational capabilities to, and offer some survivability improvements over, the existing defense avionics system. The only reason for additional testing would be to prove that some problems with the maintenance diagnostic system has been resolved. Initial testing revealed that while some improvements were achieved, usermore » requirements were not met for such things as low false alarm rates and cannot duplicate rates. Even if the maintenance diagnostic capabilities were fully demonstrated, however, the CORE system should not be implemented until it is known whether the defense avionics system design can support the B-1B's new role as a conventional bomber.« less

  7. Quality issues with malaria rapid diagnostic test accessories and buffer packaging: findings from a 5-country private sector project in Africa.

    PubMed

    Harvey, Steven A; Incardona, Sandra; Martin, Nina; Lussiana, Cristina; Streat, Elizabeth; Dolan, Stephanie; Champouillon, Nora; Kyabayinze, Daniel J; Mugerwa, Robert; Nakanwagi, Grace; Njoki, Nancy; Rova, Ratsimandisa; Cunningham, Jane

    2017-04-20

    Use of antigen-detecting malaria rapid diagnostic tests (RDTs) has increased exponentially over the last decade. WHO's Global Malaria Programme, FIND, and other collaborators have established a quality assurance scheme to guide product selection, lot verification, transport, storage, and training procedures. Recent concerns over the quality of buffer packaging and test accessories suggest a need to include these items in product assessments. This paper describes quality problems with buffer and accessories encountered in a project promoting private sector RDT use in five African countries and suggests steps to avoid or more rapidly identify and resolve such problems. Private provider complaints about RDT buffer vials and kit accessories were collected during supervisory visits, and a standard assessment process was developed. Using 100 tests drawn from six different lots produced by two manufacturers, lab technicians visually assessed alcohol swab packaging, blood transfer device (BTD) usability, and buffer appearance, then calculated mean blood volume from 10 BTD transfers and mean buffer volume from 10 individual buffer vials. WHO guided complaint reporting and follow-up with manufacturers. Supervisory visits confirmed user reports of dry alcohol swabs, poorly functioning BTDs, and non-uniform volumes of buffer. Lot testing revealed further evidence of quality problems, leading one manufacturer to replace buffer vials and accessories for 40,000 RDTs. In December 2014, WHO issued an Information Notice for Users regarding variable buffer volumes in single-use vials and recommended against procurement of these products until defects were addressed. Though not necessarily comprehensive or generalizable, the findings presented here highlight the need for extending quality assessment to all malaria RDT test kit contents. Defects such as those described in this paper could reduce test accuracy and increase probability of invalid, false positive, or false negative results. Such deficiencies could undermine provider confidence in RDTs, prompting a return to presumptive treatment or reliance on poor quality microscopy. In partial response to this experience, WHO, FIND, and other project partners have developed guidance on documenting, troubleshooting, reporting, and resolving such problems when they occur.

  8. 48 CFR 1329.101 - Resolving tax problems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Resolving tax problems. 1329.101 Section 1329.101 Federal Acquisition Regulations System DEPARTMENT OF COMMERCE GENERAL CONTRACTING REQUIREMENTS TAXES General 1329.101 Resolving tax problems. Legal questions relating to tax issues...

  9. Diagnostics of underwater electrical wire explosion through a time- and space-resolved hard x-ray source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheftman, D.; Shafer, D.; Efimov, S.

    2012-10-15

    A time- and space-resolved hard x-ray source was developed as a diagnostic tool for imaging underwater exploding wires. A {approx}4 ns width pulse of hard x-rays with energies of up to 100 keV was obtained from the discharge in a vacuum diode consisting of point-shaped tungsten electrodes. To improve contrast and image quality, an external pulsed magnetic field produced by Helmholtz coils was used. High resolution x-ray images of an underwater exploding wire were obtained using a sensitive x-ray CCD detector, and were compared to optical fast framing images. Future developments and application of this diagnostic technique are discussed.

  10. Diagnostics of underwater electrical wire explosion through a time- and space-resolved hard x-ray source.

    PubMed

    Sheftman, D; Shafer, D; Efimov, S; Gruzinsky, K; Gleizer, S; Krasik, Ya E

    2012-10-01

    A time- and space-resolved hard x-ray source was developed as a diagnostic tool for imaging underwater exploding wires. A ~4 ns width pulse of hard x-rays with energies of up to 100 keV was obtained from the discharge in a vacuum diode consisting of point-shaped tungsten electrodes. To improve contrast and image quality, an external pulsed magnetic field produced by Helmholtz coils was used. High resolution x-ray images of an underwater exploding wire were obtained using a sensitive x-ray CCD detector, and were compared to optical fast framing images. Future developments and application of this diagnostic technique are discussed.

  11. 48 CFR 629.101 - Resolving tax problems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Resolving tax problems... REQUIREMENTS TAXES General 629.101 Resolving tax problems. In certain instances, acquisitions by posts are exempt from various taxes in foreign countries. Contracting officers shall ascertain such exemptions and...

  12. 48 CFR 229.101 - Resolving tax problems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Resolving tax problems..., DEPARTMENT OF DEFENSE GENERAL CONTRACTING REQUIREMENTS TAXES General 229.101 Resolving tax problems. (a... information on fuel excise taxes, see PGI 229.101(b). (c) For guidance on directing a contractor to litigate...

  13. Holographic flow diagnostics for the Space Shuttle main engine

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Summarized here are the results of an effort to produce holograms of the exhaust from the Space Shuttle Main Engine (SSME) being tested on a test stand at the Marshall Space Flight Center (MSFC). The effort took place from December 1990 to January 1992, during which seven trips were made from MetroLaser to MSFC. A brief outline of each trip is given. Due to the suspension of the SSME program in Huntsville and unexpected complications in resolving safety issues, the proposed holography system was not operated until November 1991. A NASA 100 mW Argon laser was installed in the holography system for an October engine test while these safety issues were being resolved. A video camera shadowgraph was made during this test, which was shut down prematurely after 20 seconds. System problems precluded successful operation of the holography system until the January 1992 engine test. No hologram resulted during this test due to heavy fog conditions around the engine.

  14. Image-guided fine-needle aspiration of retroperitoneal masses: The role of the cytopathologist.

    PubMed

    Mehdi, Ghazala; Maheshwari, Veena; Afzal, Sheerin; Ansari, Hena A; Ahmad, Ibne

    2013-01-01

    Retroperitoneal tumors constitute a difficult diagnostic category as they are not easily accessible. The advent of image-guided fine-needle aspiration (FNA) has resolved this problem significantly. We present a short study based on guided aspiration of retroperitoneal tumors, in which we have tried to assess the role of image-guided fine-needle aspiration cytology as a tool for pre-operative diagnosis. The study was conducted on patients diagnosed with retroperitoneal masses. FNA was performed under image guidance with the help of ultrasonography and/or computed tomography; smears were prepared and meticulously screened according to a fixed protocol. The results were analyzed to determine sensitivity, specificity, and diagnostic efficacy of cytopathological diagnosis using image-guided FNA techniques. We assessed 38 patients with retroperitoneal masses. In all cases, adequate cellular material was obtained. No major complications were encountered. Statistical analysis was carried out in 35 cases; sensitivity, specificity, and diagnostic accuracy were 100% in these cases. FNA under image guidance should be considered a first-line diagnostic approach for retroperitoneal and other abdominal tumors, although caution should be exercised in case selection. In areas where advanced tests are not available, the cytotechnologist and cytopathologist have a very important role to play in ensuring accurate diagnoses.

  15. Process-Oriented Diagnostics of Tropical Cyclones in Global Climate Models

    NASA Astrophysics Data System (ADS)

    Moon, Y.; Kim, D.; Camargo, S. J.; Wing, A. A.; Sobel, A. H.; Bosilovich, M. G.; Murakami, H.; Reed, K. A.; Vecchi, G. A.; Wehner, M. F.; Zarzycki, C. M.; Zhao, M.

    2017-12-01

    Simulating tropical cyclone (TC) activity with global climate models (GCMs) remains a challenging problem. While some GCMs are able to simulate TC activity that is in good agreement with the observations, many other models exhibit strong biases. Decreasing horizontal grid spacing of the GCM simulations tends to improve the characteristics of simulated TCs, but this enhancement alone does not necessarily lead to greater skill in simulating TC activity. This study uses process-based diagnostics to identify model characteristics that could explain why some GCM simulations are able to produce more realistic TC activity than others. The diagnostics examine how convection, moisture, clouds and related processes are coupled at individual grid points, which yields useful information into how convective parameterizations interact with resolved model dynamics. These diagnostics share similarities with those originally developed to examine the Madden-Julian Oscillations in climate models. This study will examine TCs in eight different GCM simulations performed at NOAA/GFDL, NCAR and NASA that have different horizontal resolutions and ocean coupling. Preliminary results suggest that stronger TCs are closely associated with greater rainfall - thus greater diabatic heating - in the inner-core regions of the storms, which is consistent with previous theoretical studies. Other storm characteristics that can be used to infer why GCM simulations with comparable horizontal grid spacings produce different TC activity will be examined.

  16. The resolvent of singular integral equations. [of kernel functions in mixed boundary value problems

    NASA Technical Reports Server (NTRS)

    Williams, M. H.

    1977-01-01

    The investigation reported is concerned with the construction of the resolvent for any given kernel function. In problems with ill-behaved inhomogeneous terms as, for instance, in the aerodynamic problem of flow over a flapped airfoil, direct numerical methods become very difficult. A description is presented of a solution method by resolvent which can be employed in such problems.

  17. Multimodal optical imager for inner ear hearing loss diagnosis (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Park, Jesung; Maguluri, Gopi N.; Zhao, Youbo; Iftimia, Nicusor V.

    2017-02-01

    Sensorineural hearing loss (SNHL), which typically originates in the cochlea, is the most common otologic problem caused by aging and noise trauma. The cochlea, a delicate and complex biological mechanosensory transducer in the inner ear, has been extensively studied with the goal of improving diagnosis of SNHL. However, the difficulty associated with accessing the cochlea and resolving the microstructures that facilitate hearing within it in a minimally-invasive way has prevented us from being able to assess the pathology underlying SNHL in humans. To address this problem we investigated the ability of a multimodal optical system that combines optical coherence tomography (OCT) and single photon autofluorescence imaging (AFI) to enable visualization and evaluation of microstructures in the cochlea. A laboratory OCT/AFI imager was built to acquire high resolution OCT and single photon fluorescence images of the cochlea. The imager's ability to resolve diagnostically-relevant details was evaluated in ears extracted from normal and noise-exposed mice. A prototype endoscopic OCT/AFI imager was developed based on a double-clad fiber approach. Our measurements show that the multimodal OCT/AFI imager can be used to evaluate structural integrity in the mouse cochlea. Therefore, we believe that this technology is promising as a potential clinical evaluation tool, and as a technique for guiding otologic surgeries such as cochlear implant surgery.

  18. Practical Approaches to Resolving Behaviour Problems. Selected Papers from the National Conference on Practical Approaches to Resolving Behaviour Problems (2nd, Sydney, New South Wales, Australia, July 1990). Programs Implementation and System Initiatives.

    ERIC Educational Resources Information Center

    Richardson, Susanna, Ed.; Izard, John, Ed.

    This collection of papers focuses on practical approaches to resolving behavior problems in the Australian school system. The papers are divided into four general categories: perspectives on behavior problems, focusing on families, schools and system initiatives, and programs in special settings. The papers include: (1) "Beyond…

  19. Time resolved Thomson scattering diagnostic of pulsed gas metal arc welding (GMAW) process

    NASA Astrophysics Data System (ADS)

    Kühn-Kauffeldt, M.; Marquès, J. L.; Schein, J.

    2014-11-01

    In this work a Thomson scattering diagnostic technique was applied to obtain time resolved electron temperature and density values during a gas metal arc welding (GMAW) process. The investigated GMAW process was run with aluminum wire (AlMg 4,5 Mn) with 1.2 mm diameter as a wire electrode, argon as a shielding gas and peak currents in the range of 400 A. Time resolved measurements could be achieved by triggering the laser pulse at shifted time positions with respect to the current pulse driving the process. Time evaluation of resulting electron temperatures and densities is used to investigate the state of the plasma in different phases of the current pulse and to determine the influence of the metal vapor and droplets on the plasma properties.

  20. Human prenatal diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filkins, K.; Russo, J.F.

    Advances in the field of prenatal diagnosis have been rapid during the past decade. Moreover, liberal use of birth control methods and restriction of family size have placed greater emphasis on optimum outcome of each pregnancy. There are many prenatal diagnostic techniques of proven value; the risks, including false negatives and false positives, are known. With the rapid proliferation of new and experimental techniques, many disorders are potential diagnosable or even treatable; however, risk factors are unknown and issues relating to quality control have not been resolved. These problems are readily appreciated in the dramatic new techniques involving recombinant DNA,more » chorion villus sampling, and fetal surgery. Unfortunately, clinicians may not appreciate the difficulties that may also be encountered in the more mundane prenatal diagnostic tests such as ultrasonography or enzymatic testing. The aim of this volume is to clarify and rationalize certain aspects of diagnosis, genetic counseling, and intervention. New and experimental techniques are presented in the light of current knowledge.« less

  1. Highly sensitive time-resolved thermography and multivariate image analysis of the cerebral cortex for intrasurgical diagnostics

    NASA Astrophysics Data System (ADS)

    Hollmach, Julia; Hoffmann, Nico; Schnabel, Christian; Küchler, Saskia; Sobottka, Stephan; Kirsch, Matthias; Schackert, Gabriele; Koch, Edmund; Steiner, Gerald

    2013-03-01

    Time-resolved thermography is a novel method to assess thermal variations and heterogeneities in tissue and blood. The recent generation of thermal cameras provides a sensitivity of less than mK. This high sensitivity in conjunction with non-invasive, label-free and radiation-free monitoring makes thermography a promising tool for intrasurgical diagnostics. In brain surgery, time-resolved thermography can be employed to distinguish between normal and anomalous tissue. In this study, we investigated and discussed the potential of time-resolved thermography in neurosurgery for the intraoperative detection and demarcation of tumor borders. Algorithms for segmentation, reduction of movement artifacts and image fusion were developed. The preprocessed image stacks were subjected to discrete wavelet transform to examine individual frequency components. K-means clustering was used for image evaluation to reveal similarities within the image sequence. The image evaluation shows significant differences for both types of tissue. Tumor and normal tissues have different time characteristics in heat production and transfer. Furthermore, tumor could be highlighted. These results demonstrate that time-resolved thermography is able to support the detection of tumors in a contactless manner without any side effects for the tissue. The intraoperative usage of time-resolved thermography improves the accuracy of tumor resections to prevent irreversible brain damage during surgery.

  2. CMOS Time-Resolved, Contact, and Multispectral Fluorescence Imaging for DNA Molecular Diagnostics

    PubMed Central

    Guo, Nan; Cheung, Ka Wai; Wong, Hiu Tung; Ho, Derek

    2014-01-01

    Instrumental limitations such as bulkiness and high cost prevent the fluorescence technique from becoming ubiquitous for point-of-care deoxyribonucleic acid (DNA) detection and other in-field molecular diagnostics applications. The complimentary metal-oxide-semiconductor (CMOS) technology, as benefited from process scaling, provides several advanced capabilities such as high integration density, high-resolution signal processing, and low power consumption, enabling sensitive, integrated, and low-cost fluorescence analytical platforms. In this paper, CMOS time-resolved, contact, and multispectral imaging are reviewed. Recently reported CMOS fluorescence analysis microsystem prototypes are surveyed to highlight the present state of the art. PMID:25365460

  3. Replacing Myalgic Encephalomyelitis and Chronic Fatigue Syndrome with Systemic Exercise Intolerance Disease Is Not the Way forward

    PubMed Central

    Twisk, Frank N.M.

    2016-01-01

    Myalgic encephalomyelitis (ME), described in the medical literature since 1938, is characterized by distinctive muscular symptoms, neurological symptoms, and signs of circulatory impairment. The only mandatory feature of chronic fatigue syndrome (CFS), introduced in 1988 and redefined in 1994, is chronic fatigue, which should be accompanied by at least four or more out of eight “additional” symptoms. The use of the abstract, polythetic criteria of CFS, which define a heterogeneous patient population, and self-report has hampered both scientific progress and accurate diagnosis. To resolve the “diagnostic impasse” the Institute of Medicine proposes that a new clinical entity, systemic exercise intolerance disease (SEID), should replace the clinical entities ME and CFS. However, adopting SEID and its defining symptoms, does not resolve methodological and diagnostic issues. Firstly, a new diagnostic entity cannot replace two distinct, partially overlapping, clinical entities such as ME and CFS. Secondly, due to the nature of the diagnostic criteria, the employment of self-report, and the lack of criteria to exclude patients with other conditions, the SEID criteria seem to select an even more heterogeneous patient population, causing additional diagnostic confusion. This article discusses methodological and diagnostic issues related to SEID and proposes a methodological solution for the current “diagnostic impasse”. PMID:26861399

  4. Time-resolved contrast-enhanced MR angiography of the thorax in adults with congenital heart disease.

    PubMed

    Mohrs, Oliver K; Petersen, Steffen E; Voigtlaender, Thomas; Peters, Jutta; Nowak, Bernd; Heinemann, Markus K; Kauczor, Hans-Ulrich

    2006-10-01

    The aim of this study was to evaluate the diagnostic value of time-resolved contrast-enhanced MR angiography in adults with congenital heart disease. Twenty patients with congenital heart disease (mean age, 38 +/- 14 years; range, 16-73 years) underwent contrast-enhanced turbo fast low-angle shot MR angiography. Thirty consecutive coronal 3D slabs with a frame rate of 1-second duration were acquired. The mask defined as the first data set was subtracted from subsequent images. Image quality was evaluated using a 5-point scale (from 1, not assessable, to 5, excellent image quality). Twelve diagnostic parameters yielded 1 point each in case of correct diagnosis (binary analysis into normal or abnormal) and were summarized into three categories: anatomy of the main thoracic vessels (maximum, 5 points), sequential cardiac anatomy (maximum, 5 points), and shunt detection (maximum, 2 points). The results were compared with a combined clinical reference comprising medical or surgical reports and other imaging studies. Diagnostic accuracies were calculated for each of the parameters as well as for the three categories. The mean image quality was 3.7 +/- 1.0. Using a binary approach, 220 (92%) of the 240 single diagnostic parameters could be analyzed. The percentage of maximum diagnostic points, the sensitivity, the specificity, and the positive and the negative predictive values were all 100% for the anatomy of the main thoracic vessels; 97%, 87%, 100%, 100%, and 96% for sequential cardiac anatomy; and 93%, 93%, 92%, 88%, and 96% for shunt detection. Time-resolved contrast-enhanced MR angiography provides, in one breath-hold, anatomic and qualitative functional information in adult patients with congenital heart disease. The high diagnostic accuracy allows the investigator to tailor subsequent specific MR sequences within the same session.

  5. Recent Advances in Fluorescence Lifetime Analytical Microsystems: Contact Optics and CMOS Time-Resolved Electronics.

    PubMed

    Wei, Liping; Yan, Wenrong; Ho, Derek

    2017-12-04

    Fluorescence spectroscopy has become a prominent research tool with wide applications in medical diagnostics and bio-imaging. However, the realization of combined high-performance, portable, and low-cost spectroscopic sensors still remains a challenge, which has limited the technique to the laboratories. A fluorescence lifetime measurement seeks to obtain the characteristic lifetime from the fluorescence decay profile. Time-correlated single photon counting (TCSPC) and time-gated techniques are two key variations of time-resolved measurements. However, commercial time-resolved analysis systems typically contain complex optics and discrete electronic components, which lead to bulkiness and a high cost. These two limitations can be significantly mitigated using contact sensing and complementary metal-oxide-semiconductor (CMOS) implementation. Contact sensing simplifies the optics, whereas CMOS technology enables on-chip, arrayed detection and signal processing, significantly reducing size and power consumption. This paper examines recent advances in contact sensing and CMOS time-resolved circuits for the realization of fully integrated fluorescence lifetime measurement microsystems. The high level of performance from recently reported prototypes suggests that the CMOS-based contact sensing microsystems are emerging as sound technologies for application-specific, low-cost, and portable time-resolved diagnostic devices.

  6. Recent Advances in Fluorescence Lifetime Analytical Microsystems: Contact Optics and CMOS Time-Resolved Electronics

    PubMed Central

    Yan, Wenrong; Ho, Derek

    2017-01-01

    Fluorescence spectroscopy has become a prominent research tool with wide applications in medical diagnostics and bio-imaging. However, the realization of combined high-performance, portable, and low-cost spectroscopic sensors still remains a challenge, which has limited the technique to the laboratories. A fluorescence lifetime measurement seeks to obtain the characteristic lifetime from the fluorescence decay profile. Time-correlated single photon counting (TCSPC) and time-gated techniques are two key variations of time-resolved measurements. However, commercial time-resolved analysis systems typically contain complex optics and discrete electronic components, which lead to bulkiness and a high cost. These two limitations can be significantly mitigated using contact sensing and complementary metal-oxide-semiconductor (CMOS) implementation. Contact sensing simplifies the optics, whereas CMOS technology enables on-chip, arrayed detection and signal processing, significantly reducing size and power consumption. This paper examines recent advances in contact sensing and CMOS time-resolved circuits for the realization of fully integrated fluorescence lifetime measurement microsystems. The high level of performance from recently reported prototypes suggests that the CMOS-based contact sensing microsystems are emerging as sound technologies for application-specific, low-cost, and portable time-resolved diagnostic devices. PMID:29207568

  7. SDSS-IV MaNGA: identification of active galactic nuclei in optical integral field unit surveys

    NASA Astrophysics Data System (ADS)

    Wylezalek, Dominika; Zakamska, Nadia L.; Greene, Jenny E.; Riffel, Rogemar A.; Drory, Niv; Andrews, Brett H.; Merloni, Andrea; Thomas, Daniel

    2018-02-01

    In this paper, we investigate 2727 galaxies observed by MaNGA as of 2016 June to develop spatially resolved techniques for identifying signatures of active galactic nuclei (AGNs). We identify 303 AGN candidates. The additional spatial dimension imposes challenges in identifying AGNs due to contamination from diffuse ionized gas, extraplanar gas and photoionization by hot stars. We show that the combination of spatially resolved line diagnostic diagrams and additional cuts on H α surface brightness and H α equivalent width can distinguish between AGN-like signatures and high-metallicity galaxies with low-ionization nuclear emission-line regions-like spectra. Low-mass galaxies with high specific star formation rates are particularly difficult to diagnose and routinely show diagnostic line ratios outside of the standard star formation locus. We develop a new diagnostic - the distance from the standard diagnostic line in the line-ratio space - to evaluate the significance of the deviation from the star formation locus. We find 173 galaxies that would not have been selected as AGN candidates based on single-fibre spectral measurements but exhibit photoionization signatures suggestive of AGN activity in the Mapping Nearby Galaxies at APO resolved observations, underscoring the power of large integral field unit surveys. A complete census of these new AGN candidates is necessary to understand their nature and probe the complex co-evolution of supermassive black holes and their hosts.

  8. Thermal conductivity study of warm dense matter by differential heating on LCLS and Titan

    NASA Astrophysics Data System (ADS)

    Hill, M.; McKelvey, A.; Jiang, S.; Shepherd, R.; Hau-Riege, S.; Whitley, H.; Sterne, P.; Hamel, S.; Collins, G.; Ping, Y.; Brown, C.; Floyd, E.; Fyrth, J.; Hoarty, D.; Hua, R.; Bailly-Grandvaux, M.; Beg, F.; Cho, B.; Kim, M.; Lee, J.; Lee, H.; Galtier, E.

    2017-10-01

    A differential heating platform has been developed for thermal conduction study, where a temperature gradient is induced and subsequent heat flow is probed by time-resolved diagnostics. Multiple experiment using this platform have been carried out at LCLS-MEC and Titan laser facilities for warm dense Al, Fe, amorphous carbon and diamond. Two single-shot time-resolved diagnostics are employed, SOP (streaked optical pyrometry) for surface temperature and FDI (Fourier Domain Interferometry) for surface expansion. Both diagnostics provided excellent data to constrain release equation-of-state (EOS) and thermal conductivity. Data sets with varying target thickness and comparison between simulations with different thermal conductivity models are presented. This work was performed under DOE contract DE-AC52-07NA27344 with support from DOE OFES Early Career program and LLNL LDRD program.

  9. Hybrid Optical-Ultrasonic Technique for Biomedical Diagnostics

    PubMed Central

    Marcu, L.; Sun, Y.; Stephens, D.; Park, J.; Farwell, D. G.; Shung, K. K.

    2010-01-01

    We report the development of a diagnostic system combining time-resolved fluorescence spectroscopy and ultrasound backscatter microscopy and its application in diagnosis of tumors and atherosclerotic disease. This system allows for concurrent evaluation of distinct compositional, functional, and micro-anatomical features of normal and diseased tissues. PMID:21918737

  10. Monte Carlo based investigation of berry phase for depth resolved characterization of biomedical scattering samples

    NASA Astrophysics Data System (ADS)

    Baba, J. S.; Koju, V.; John, D.

    2015-03-01

    The propagation of light in turbid media is an active area of research with relevance to numerous investigational fields, e.g., biomedical diagnostics and therapeutics. The statistical random-walk nature of photon propagation through turbid media is ideal for computational based modeling and simulation. Ready access to super computing resources provide a means for attaining brute force solutions to stochastic light-matter interactions entailing scattering by facilitating timely propagation of sufficient (>107) photons while tracking characteristic parameters based on the incorporated physics of the problem. One such model that works well for isotropic but fails for anisotropic scatter, which is the case for many biomedical sample scattering problems, is the diffusion approximation. In this report, we address this by utilizing Berry phase (BP) evolution as a means for capturing anisotropic scattering characteristics of samples in the preceding depth where the diffusion approximation fails. We extend the polarization sensitive Monte Carlo method of Ramella-Roman, et al., to include the computationally intensive tracking of photon trajectory in addition to polarization state at every scattering event. To speed-up the computations, which entail the appropriate rotations of reference frames, the code was parallelized using OpenMP. The results presented reveal that BP is strongly correlated to the photon penetration depth, thus potentiating the possibility of polarimetric depth resolved characterization of highly scattering samples, e.g., biological tissues.

  11. Monte Carlo based investigation of Berry phase for depth resolved characterization of biomedical scattering samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baba, Justin S; John, Dwayne O; Koju, Vijay

    The propagation of light in turbid media is an active area of research with relevance to numerous investigational fields, e.g., biomedical diagnostics and therapeutics. The statistical random-walk nature of photon propagation through turbid media is ideal for computational based modeling and simulation. Ready access to super computing resources provide a means for attaining brute force solutions to stochastic light-matter interactions entailing scattering by facilitating timely propagation of sufficient (>10million) photons while tracking characteristic parameters based on the incorporated physics of the problem. One such model that works well for isotropic but fails for anisotropic scatter, which is the case formore » many biomedical sample scattering problems, is the diffusion approximation. In this report, we address this by utilizing Berry phase (BP) evolution as a means for capturing anisotropic scattering characteristics of samples in the preceding depth where the diffusion approximation fails. We extend the polarization sensitive Monte Carlo method of Ramella-Roman, et al.,1 to include the computationally intensive tracking of photon trajectory in addition to polarization state at every scattering event. To speed-up the computations, which entail the appropriate rotations of reference frames, the code was parallelized using OpenMP. The results presented reveal that BP is strongly correlated to the photon penetration depth, thus potentiating the possibility of polarimetric depth resolved characterization of highly scattering samples, e.g., biological tissues.« less

  12. Time-resolved energy spectrum measurement of a linear induction accelerator with the magnetic analyzer

    NASA Astrophysics Data System (ADS)

    Wang, Yuan; Jiang, Xiao-Guo; Yang, Guo-Jun; Chen, Si-Fu; Zhang, Zhuo; Wei, Tao; Li, Jin

    2015-01-01

    We recently set up a time-resolved optical beam diagnostic system. Using this system, we measured the high current electron beam energy in the accelerator under construction. This paper introduces the principle of the diagnostic system, describes the setup, and shows the results. A bending beam line was designed using an existing magnetic analyzer with a 300 mm-bending radius and a 60° bending angle at hard-edge approximation. Calculations show that the magnitude of the beam energy is about 18 MeV, and the energy spread is within 2%. Our results agree well with the initial estimates deduced from the diode voltage approach.

  13. Resolvent approach for two-dimensional scattering problems. Application to the nonstationary Schrödinger problem and the KPI equation

    NASA Astrophysics Data System (ADS)

    Boiti, M.; Pempinelli, F.; Pogrebkov, A. K.; Polivanov, M. C.

    1992-11-01

    The resolvent operator of the linear problem is determined as the full Green function continued in the complex domain in two variables. An analog of the known Hilbert identity is derived. We demonstrate the role of this identity in the study of two-dimensional scattering. Considering the nonstationary Schrödinger equation as an example, we show that all types of solutions of the linear problems, as well as spectral data known in the literature, are given as specific values of this unique function — the resolvent function. A new form of the inverse problem is formulated.

  14. Promoting Health by Addressing Basic Needs: Effect of Problem Resolution on Contacting Health Referrals.

    PubMed

    Thompson, Tess; Kreuter, Matthew W; Boyum, Sonia

    2016-04-01

    Members of vulnerable populations have heightened needs for health services. One advantage of integrating health risk assessment and referrals into social service assistance systems such as 2-1-1 is that such systems help callers resolve problems in other areas (e.g., housing). Callers to 2-1-1 in Missouri (N= 1,090) with at least one behavioral risk factor or cancer screening need were randomly assigned to one of three health referral interventions: verbal referrals only, verbal referrals + a tailored mailed reminder, or verbal referrals + telephone health navigator. After 1 month, we assessed whether the nonhealth problems that prompted the 2-1-1 call had been resolved. Logistic regression estimated effects of having the problem resolved on calling a health referral. Callers were predominantly female (85%) and had a high school education or less (61%); nearly half (47%) had incomes under $10,000. The most common service requests were for utility assistance (35%), home/family problems (23%), and rent/mortgage assistance (12%). At follow-up, 38% of callers reported that all problems prompting their 2-1-1 call had been resolved, and 24% reported calling a health referral. Resolving all problems prompting the 2-1-1 call was associated with a higher odds of contacting a health referral (odds ratio = 1.44, 95% confidence interval [1.02, 2.05]) compared to people whose problems were not resolved. Multifaceted interventions that help meet non-health-related needs and provide support in reaching health-related goals may promote health in vulnerable populations. © 2015 Society for Public Health Education.

  15. Promoting Health by Addressing Basic Needs: Effect of Problem Resolution on Contacting Health Referrals

    PubMed Central

    Thompson, Tess; Kreuter, Matthew; Boyum, Sonia

    2016-01-01

    Members of vulnerable populations have heightened needs for health services. One advantage of integrating health risk assessment and referrals into social service assistance systems such as 2-1-1 is that such systems help callers resolve problems in other areas (e.g. housing). Callers to 2-1-1 in Missouri (N=1090) with at least one behavioral risk factor or cancer screening need were randomly assigned to one of three health referral interventions: verbal referrals only, verbal referrals + a tailored mailed reminder, or verbal referrals + telephone health navigator. After one month, we assessed whether the non-health problems that prompted the 2-1-1 call had been resolved. Logistic regression estimated effects of having the problem resolved on calling a health referral. Callers were predominantly female (85%) and had a high school education or less (61%); nearly half (47%) had incomes under $10,000. The most common service requests were for utility assistance (35%), home/family problems (23%), and rent/mortgage assistance (12%). At follow-up, 38% of callers reported that all problems prompting their 2-1-1 call had been resolved, and 24% reported calling a health referral. Resolving all problems prompting the 2-1-1 call was associated with a higher odds of contacting a health referral (OR = 1.44, 95% CI 1.02-2.05) compared to people whose problems were not resolved. Multifaceted interventions that help meet non-health-related needs and provide support in reaching health-related goals may promote health in vulnerable populations. PMID:26293458

  16. Diagnostic Suite for HyperV Coaxial Plasma Gun Development for the PLX- α Project

    NASA Astrophysics Data System (ADS)

    Case, Andrew; Brockington, Sam; Witherspoon, F. Douglas

    2015-11-01

    We present the diagnostic suite to be used during development of the coaxial guns HyperV will deliver to LANL in support of the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. For plasma jet diagnostics this includes fast photodiodes for velocimetry, a ballistic pendulum for measuring total plasmoid momentum, interferometry for line integrated plasma density, deflectometry for line integrated perpendicular density gradient measurements, and spectroscopy, both time resolved high resolution spectroscopy using a novel detector developed by HyperV and time integrated survey spectroscopy, for measurements of velocity and temperature as well as impurities. In addition, we plan to use fast pressure probes for stagnation pressure, a Faraday cup for density, fast imaging for plume geometry and time integrated imaging for overall light emission. A novel low resolution long record length camera developed by HyperV will also be used for plume diagnostics. For diagnostics of gun operation, we will use Rogowski coils to measure current, voltage dividers for voltages, B-dot probes for magnetic field, and time resolved fast photodiodes to measure plasmoid velocity inside the accelerator. This work supported by the ARPA-E ALPHA program.

  17. Eighteen Years of Molecular Genotyping the Hemophilia Inversion Hotspot: From Southern Blot to Inverse Shifting-PCR

    PubMed Central

    Rossetti, Liliana C.; Radic, Claudia P.; Abelleyro, Miguel M.; Larripa, Irene B.; De Brasi, Carlos D.

    2011-01-01

    The factor VIII gene (F8) intron 22 inversion (Inv22) is a paradigmatic duplicon-mediated rearrangement, found in about one half of patients with severe hemophilia A worldwide. The identification of this prevalent cause of hemophilia was delayed for nine years after the F8 characterization in 1984. The aim of this review is to present the wide diversity of practical approaches that have been developed for genotyping the Inv22 (and related int22h rearrangements) since discovery in 1993. The sequence— Southern blot, long distance-PCR and inverse shifting-PCR—for Inv22 genotyping is an interesting example of scientific ingenuity and evolution in order to resolve challenging molecular diagnostic problems. PMID:22072947

  18. Application of NIR spectroscopy in the assessment of diabetic foot disorders

    NASA Astrophysics Data System (ADS)

    Schleicher, Eckhard; Hampel, Uwe; Freyer, Richard

    2001-10-01

    Diabetic foot syndrome (DFS) is a common sequel of long-term diabetes mellitus. There is a urgent need of noninvasive, objective and quantitative diagnostic tools to assess tissue viability and perfusion for a successful therapy. NIR spectroscopy seems to be qualified to measure local capillary hemoglobin saturation of the outer extremities in patients with progressive diabetic disorders. We investigate how NIR spectroscopy can be applied to the assessment of diabetic foot problems such as neuropathy and angiopathy. Thereby we use spatially resolved spectroscopy in conjunction with a specially developed continuous-wave laser spectrometer. Comparison of intra- and interindividual measurements is expected to yield quantitative measures of local tissue viability which is a prerequisite for a successful therapy.

  19. Clinical Diagnosis of the Dampness and Mold Hypersensitivity Syndrome: Review of the Literature and Suggested Diagnostic Criteria

    PubMed Central

    Valtonen, Ville

    2017-01-01

    A great variety of non-specific symptoms may occur in patients living or working in moisture-damaged buildings. In the beginning, these symptoms are usually reversible, mild, and present irritation of mucosa and increased morbidity due to respiratory tract infections and asthma-like symptoms. Later, the disease may become chronic and a patient is referred to a doctor where the assessment of dampness and mold hypersensitivity syndrome (DMHS) often presents diagnostic challenges. Currently, unanimously accepted laboratory tests are not yet available. Therefore, the diagnosis of DMHS is clinical and is based on the patient’s history and careful examination. In this publication, I reviewed contemporary knowledge on clinical presentations, laboratory methods, and clinical assessment of DMHS. From the literature, I have not found any proposed diagnostic clinical criteria. Therefore, I propose five clinical criteria to diagnose DMHS: (1) the history of mold exposure in water-damaged buildings, (2) increased morbidity to due infections, (3) sick building syndrome, (4) multiple chemical sensitivity, and (5) enhanced scent sensitivity. If all the five criteria are met, the patient has a very probable DMHS. To resolve the current problems in assigning correct DMHS diagnosis, we also need novel assays to estimate potential risks of developing DMHS. PMID:28848553

  20. Clinical Diagnosis of the Dampness and Mold Hypersensitivity Syndrome: Review of the Literature and Suggested Diagnostic Criteria.

    PubMed

    Valtonen, Ville

    2017-01-01

    A great variety of non-specific symptoms may occur in patients living or working in moisture-damaged buildings. In the beginning, these symptoms are usually reversible, mild, and present irritation of mucosa and increased morbidity due to respiratory tract infections and asthma-like symptoms. Later, the disease may become chronic and a patient is referred to a doctor where the assessment of dampness and mold hypersensitivity syndrome (DMHS) often presents diagnostic challenges. Currently, unanimously accepted laboratory tests are not yet available. Therefore, the diagnosis of DMHS is clinical and is based on the patient's history and careful examination. In this publication, I reviewed contemporary knowledge on clinical presentations, laboratory methods, and clinical assessment of DMHS. From the literature, I have not found any proposed diagnostic clinical criteria. Therefore, I propose five clinical criteria to diagnose DMHS: (1) the history of mold exposure in water-damaged buildings, (2) increased morbidity to due infections, (3) sick building syndrome, (4) multiple chemical sensitivity, and (5) enhanced scent sensitivity. If all the five criteria are met, the patient has a very probable DMHS. To resolve the current problems in assigning correct DMHS diagnosis, we also need novel assays to estimate potential risks of developing DMHS.

  1. Diagnostic Problem-Solving Process in Professional Contexts: Theory and Empirical Investigation in the Context of Car Mechatronics Using Computer-Generated Log-Files

    ERIC Educational Resources Information Center

    Abele, Stephan

    2018-01-01

    This article deals with a theory-based investigation of the diagnostic problem-solving process in professional contexts. To begin with, a theory of the diagnostic problem-solving process was developed drawing on findings from different professional contexts. The theory distinguishes between four sub-processes of the diagnostic problem-solving…

  2. Improving acute patient flow and resolving emergency department overcrowding in New Zealand hospitals--the major challenges and the promising initiatives.

    PubMed

    Ardagh, Michael W; Tonkin, Gary; Possenniskie, Clare

    2011-10-14

    To determine the most common challenges to improving acute patient flow and resolving emergency department (ED) overcrowding in New Zealand hospitals, and to share some of the promising initiatives that have been implemented in response to them. To facilitate progress towards achievement of the Shorter Stays in Emergency Departments Health Target (the Target), the authors visited every District Health Board (DHB) in New Zealand. These visits followed a standardised visit format and subsequent to each visit a report was produced that noted the observed challenges, initiatives and successes in relation to the DHB's pursuit of the Target. Using these reports, the significant challenges and the promising initiatives across all of the DHBs were collated. Access to hospital beds, access to diagnostic tests and inpatient team delays were the most common challenges, followed by increased demand for ED services, ED facility deficiencies, ED staff deficiencies, delay to discharge of inpatients, difficulty engaging hospital clinical staff in changes, difficulty accessing aged care beds, and problems at nights and weekends. Promising initiatives were noted in relation to each of these. To improve acute care, resolve ED overcrowding and achieve the Target we need a comprehensive, whole of system approach and some significant changes to the way we use our physical and human resources. To address common challenges we need to share our experiences and expertise.

  3. 48 CFR 2429.101 - Resolving tax problems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DEVELOPMENT GENERAL CONTRACTING REQUIREMENTS TAXES General 2429.101 Resolving tax problems. In order to have uniformity in HUD's treatment of the tax aspects of contracting and ensure effective cooperation with other... within HUD for handling all those tax problems. Therefore, the contracting activity will not engage in...

  4. Time-resolved fluorescence monitoring of cholesterol in peripheral blood mononuclear cells

    NASA Astrophysics Data System (ADS)

    Martinakova, Z.; Horilova, J.; Lajdova, I.; Marcek Chorvatova, A.

    2014-12-01

    Precise evaluation of intracellular cholesterol distribution is crucial for improving diagnostics of diseased states associated with cholesterol alteration. Time-resolved fluorescence techniques are tested for non-invasive investigation of cholesterol in living cells. Fluorescent probe NBD attached to cholesterol was employed to evaluate cholesterol distribution in peripheral blood mononuclear cells (PBMC) isolated from the human blood. Fluorescence Lifetime Imaging Microscopy (FLIM) was successfully applied to simultaneously monitor the spatial distribution and the timeresolved characteristics of the NBD-cholesterol fluorescence in PBMC. Gathered data are the first step in the development of a new perspective non-invasive diagnostic method for evaluation of cholesterol modifications in diseases associated with disorders of lipid metabolism.

  5. Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Luo, S. N.; Jensen, B. J.; Hooks, D. E.; Fezzaa, K.; Ramos, K. J.; Yeager, J. D.; Kwiatkowski, K.; Shimada, T.

    2012-07-01

    The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial (˜2 μm) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

  6. NGC 3393: multi-component AGN feedback as seen by CHEERS

    NASA Astrophysics Data System (ADS)

    Maksym, W. Peter; Fabbiano, Giuseppina; Elvis, Martin; Karovska, Margarita; Raymond, John C.; Storchi-Bergmann, Thaisa; Paggi, Alessandro; Wang, Junfeng; Risaliti, Guido

    2017-01-01

    Due to its low density, moderate ionization, and weak kinematics, the narrow line region (NLR) of active galactic nuclei (AGN) provides poweful diagnostics for investigating AGN feedback. The CHandra Extended Emission line Region Survey (CHEERS) is the ultimate investigation into resolved feedback in the NLR. We present results from our CHEERS investigations of NGC 3393. By imaging extended X-ray line emission of NGC 3393 with Chandra and optical line emission with Hubble's narrow-band filters, we are able to map out the simultaneous impact of photoionization, jets and an AGN disk-wind. When resolved on scales of ~10s of parsecs, the NLR of NGC 3393 shows a complex multi-component medium. Diagnostic line mapping indicates a Low-ionization Emmision Line Region (LINER) cocoon surrounding the outflow-evacuated cavities (in optical) and surrounding the supports the presence of collisional plasma (in X-rays). These physically distinct constituent regions can only be resolved by the high-resolution imaging that Chandra and HST enable.

  7. Characterization of spatially resolved high resolution x-ray spectrometers for HEDP and light-source experiments

    NASA Astrophysics Data System (ADS)

    Hill, K. W.; Bitter, M.; Delgado-Aparicio, L.; Efthimion, P.; Pablant, N.; Lu, J.; Beiersdorfer, P.; Chen, H.; Magee, E.

    2014-10-01

    A high resolution 1D imaging x-ray spectrometer concept comprising a spherically bent crystal and a 2D pixelated detector is being optimized for diagnostics of small sources such as high energy density physics (HEDP) and synchrotron radiation or x-ray free electron laser experiments. This instrument is used on tokamak experiments for measurement of spatial profiles of Doppler ion temperature and plasma flow velocity, as well as electron temperature. Laboratory measurements demonstrate a resolving power, E/ ΔE of 10,000 and spatial resolution better than 10 μm. Good performance is obtained for Bragg angles ranging from 23 to 63 degrees. Initial tests of the instrument on HEDP plasmas are being performed with a goal of developing spatially resolved ion and electron temperature diagnostics. This work was performed under the auspices of the US DOE by PPPL under Contract DE-AC02-09CH11466 and by LLNL under Contract DE-AC52-07NA27344.

  8. Music Education Preservice Teachers' Confidence in Resolving Behavior Problems

    ERIC Educational Resources Information Center

    Hedden, Debra G.

    2015-01-01

    The purpose of this study was to investigate whether there would be a change in preservice teachers' (a) confidence concerning the resolution of behavior problems, (b) tactics for resolving them, (c) anticipation of problems, (d) fears about management issues, and (e) confidence in methodology and pedagogy over the time period of a one-semester…

  9. An analytic approach to resolving problems in medical ethics.

    PubMed Central

    Candee, D; Puka, B

    1984-01-01

    Education in ethics among practising professionals should provide a systematic procedure for resolving moral problems. A method for such decision-making is outlined using the two classical orientations in moral philosophy, teleology and deontology. Teleological views such as utilitarianism resolve moral dilemmas by calculating the excess of good over harm expected to be produced by each feasible alternative for action. The deontological view focuses on rights, duties, and principles of justice. Both methods are used to resolve the 1971 Johns Hopkins case of a baby born with Down's syndrome and duodenal atresia. PMID:6234395

  10. Identifying Coherent Structures in a 3-Stream Supersonic Jet Flow using Time-Resolved Schlieren Imaging

    NASA Astrophysics Data System (ADS)

    Tenney, Andrew; Coleman, Thomas; Berry, Matthew; Magstadt, Andy; Gogineni, Sivaram; Kiel, Barry

    2015-11-01

    Shock cells and large scale structures present in a three-stream non-axisymmetric jet are studied both qualitatively and quantitatively. Large Eddy Simulation is utilized first to gain an understanding of the underlying physics of the flow and direct the focus of the physical experiment. The flow in the experiment is visualized using long exposure Schlieren photography, with time resolved Schlieren photography also a possibility. Velocity derivative diagnostics are calculated from the grey-scale Schlieren images are analyzed using continuous wavelet transforms. Pressure signals are also captured in the near-field of the jet to correlate with the velocity derivative diagnostics and assist in unraveling this complex flow. We acknowledge the support of AFRL through an SBIR grant.

  11. Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging.

    PubMed

    Tremsin, Anton S; Perrodin, Didier; Losko, Adrian S; Vogel, Sven C; Bourke, Mark A M; Bizarri, Gregory A; Bourret, Edith D

    2017-04-20

    Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production. This technique is widely applicable and is not limited to crystal growth processes.

  12. Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

    NASA Astrophysics Data System (ADS)

    Tremsin, Anton S.; Perrodin, Didier; Losko, Adrian S.; Vogel, Sven C.; Bourke, Mark A. M.; Bizarri, Gregory A.; Bourret, Edith D.

    2017-04-01

    Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of “blind” processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production. This technique is widely applicable and is not limited to crystal growth processes.

  13. Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

    PubMed Central

    Tremsin, Anton S.; Perrodin, Didier; Losko, Adrian S.; Vogel, Sven C.; Bourke, Mark A.M.; Bizarri, Gregory A.; Bourret, Edith D.

    2017-01-01

    Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of “blind” processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production. This technique is widely applicable and is not limited to crystal growth processes. PMID:28425461

  14. Final Report: Resolving and Discriminating Overlapping Anomalies from Multiple Objects in Cluttered Environments

    DTIC Science & Technology

    2015-12-15

    UXO community . NAME Total Number: PERCENT_SUPPORTEDNAME FTE Equivalent: Total Number: Irma Shamatava 0.50 0.50 1 Resolving and Discriminating...Distinguishing an object of interest from innocuous items is the main problem that the UXO community is facing currently. This inverse problem...innocuous items is the main problem that the UXO community is facing currently. This inverse problem demands fast and accurate representation of

  15. Prick by Prick Induced Anaphylaxis in a Patient with Peanuts and Lupine Allergy: Awareness of Risks and Role of Component Resolved Diagnosis

    PubMed Central

    Ciccarelli, Anna; Calabrò, Claudia; Imperatore, Clara; Scala, Guglielmo

    2014-01-01

    A case of anaphylaxis is reported in the course of a prick by prick with Lupinus albus and roasted peanut in a 20-year-old woman. We focused on some main topics. First of all it seems important to underscore the potential risks connected to the practice of the prick-by-prick with fresh foods in allergic patients, especially when testing cross-reactive substances, such as White Lupine, peanuts, or soy. It is important that clinicians who perform prick tests be aware of the risk related with in vivo tests in allergic patients. Second, we discuss the problem of the hidden allergens, such as White Lupine flour, or soy flour which are utilized to improve wheat flour because of their lower cost. Patients with a demonstrated allergy to peanuts should be assessed for lupine allergy and informed about the “hidden allergens” issue. Finally, we believe that component resolved diagnosis, the serum specific IgE against molecular components, that is normally considered a second-level diagnostic step has an important role even as a first line approach at least in some selected cases. PMID:25477973

  16. Depth-resolved fluorescence of biological tissue

    NASA Astrophysics Data System (ADS)

    Wu, Yicong; Xi, Peng; Cheung, Tak-Hong; Yim, So Fan; Yu, Mei-Yung; Qu, Jianan Y.

    2005-06-01

    The depth-resolved autofluorescence ofrabbit oral tissue, normal and dysplastic human ectocervical tissue within l20μm depth were investigated utilizing a confocal fluorescence spectroscopy with the excitations at 355nm and 457nm. From the topmost keratinizing layer of oral and ectocervical tissue, strong keratin fluorescence with the spectral characteristics similar to collagen was observed. The fluorescence signal from epithelial tissue between the keratinizing layer and stroma can be well resolved. Furthermore, NADH and FADfluorescence measured from the underlying non-keratinizing epithelial layer were strongly correlated to the tissue pathology. This study demonstrates that the depth-resolved fluorescence spectroscopy can reveal fine structural information on epithelial tissue and potentially provide more accurate diagnostic information for determining tissue pathology.

  17. The diagnostic value of component-resolved diagnostics in peanut allergy in children attending a Regional Paediatric Allergology Clinic.

    PubMed

    van Veen, Leonieke N; Heron, Michiel; Batstra, Manou; van Haard, Paul M M; de Groot, Hans

    2016-06-02

    To date, diagnosing food allergies in children still presents a diagnostic dilemma, leading to uncertainty concerning the definite diagnosis of peanut allergy, as well as to the need for strict diets and the potential need for adrenalin auto-injectors. This uncertainty in particular is thought to contribute to a lower quality of life. In the diagnostic process double-blind food challenges are considered the gold standard, but they are time-consuming as well as potentially hazardous. Other diagnostic tests have been extensively studied and among these component-resolved diagnostics appeared to present a promising alternative: Ara h2, a peanut storage protein in previous studies showed to have a significant predictive value. Sixty-two out of 72 children, with suspected peanut allergy were analyzed using serum specific IgE and/or skin prick tests and specific IgE to several components of peanut (Ara h 1, 2, 3, 6, 8, 9). Subsequently, double-blind food challenges were performed. The correlation between the various diagnostic tests and the overall outcome of the double-blind food challenges were studied, in particular the severity of the reaction and the eliciting dose. The double-blind provocation with peanut was positive in 33 children (53 %). There was no relationship between the eliciting dose and the severity of the reaction. A statistically significant relationship was found between the skin prick test, specific IgE directed to peanut, Ara h 1, Ara h 2 or Ara h 6, and the outcome of the food challenge test, in terms of positive or negative (P < .001). However, we did not find any relationship between sensitisation to peanut extract or the different allergen components and the severity of the reaction or the eliciting dose. There was no correlation between IgE directed to Ara h 3, Ara h 8, Ara h 9 and the clinical outcome of the food challenge. This study shows that component-resolved diagnostics is not superior to specific IgE to peanut extract or to skin prick testing. At present, it cannot replace double-blind placebo-controlled food challenges for determination of the eliciting dose or the severity of the peanut allergy in our patient group.

  18. Chromatic-aberration diagnostic based on a spectrally resolved lateral-shearing interferometer

    DOE PAGES

    Bahk, Seung -Whan; Dorrer, Christopher; Roides, Rick G.; ...

    2016-03-18

    Here, a simple diagnostic characterizing one-dimensional chromatic aberrations in a broadband beam is introduced. A Ronchi grating placed in front of a spectrometer entrance slit provides spectrally coupled spatial phase information. The radial-group delay of a refractive system and the pulse-front delay of a wedged glass plate have been characterized accurately in a demonstration experiment.

  19. Component-resolved diagnostics in vernal conjunctivitis.

    PubMed

    Armentia, Alicia; Sanchís, Eugenia; Montero, Javier A

    2016-10-01

    Conventional diagnostic tests in allergy are insufficient to clarify the cause of vernal conjunctivitis. Component-resolved diagnostic (CRD) by microarray allergen assay may be useful in detecting allergens that might be involved in the inflammatory process. In a recent trial in patients suffered from eosinophilic esophagitis, after 2 years of the CRD-guided exclusion diet and specific immunotherapy, significant clinical improvement was observed, and 68% of patients were discharged (cure based on negative biopsy, no symptoms, and no medication intake). Our new objective was to evaluate IgE-mediated hypersensitivity by CRD in tears and serum from patients with vernal conjunctivitis and treat patients with identified triggering allergens by specific immunotherapy. Twenty-five patients with vernal conjunctivitis were evaluated. The identified triggering allergens were n Lol p 1 (11 cases), n Cyn d 1 (eight cases), group 4 and 6 grasses (six cases) and group 5 of grasses (five cases). Prick test and pollen IgE were positive in one case. Clinical improvement was observed in 13/25 vernal conjunctivitis patients after 1-year specific immunotherapy. CRD seems to be a more sensitive diagnostic tool compared with prick test and IgE detection. Specific CRD-led immunotherapy may achieve clinical improvements in vernal conjunctivitis patients.

  20. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    PubMed

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  1. Real-time diagnostics for a reusable rocket engine

    NASA Technical Reports Server (NTRS)

    Guo, T. H.; Merrill, W.; Duyar, A.

    1992-01-01

    A hierarchical, decentralized diagnostic system is proposed for the Real-Time Diagnostic System component of the Intelligent Control System (ICS) for reusable rocket engines. The proposed diagnostic system has three layers of information processing: condition monitoring, fault mode detection, and expert system diagnostics. The condition monitoring layer is the first level of signal processing. Here, important features of the sensor data are extracted. These processed data are then used by the higher level fault mode detection layer to do preliminary diagnosis on potential faults at the component level. Because of the closely coupled nature of the rocket engine propulsion system components, it is expected that a given engine condition may trigger more than one fault mode detector. Expert knowledge is needed to resolve the conflicting reports from the various failure mode detectors. This is the function of the diagnostic expert layer. Here, the heuristic nature of this decision process makes it desirable to use an expert system approach. Implementation of the real-time diagnostic system described above requires a wide spectrum of information processing capability. Generally, in the condition monitoring layer, fast data processing is often needed for feature extraction and signal conditioning. This is usually followed by some detection logic to determine the selected faults on the component level. Three different techniques are used to attack different fault detection problems in the NASA LeRC ICS testbed simulation. The first technique employed is the neural network application for real-time sensor validation which includes failure detection, isolation, and accommodation. The second approach demonstrated is the model-based fault diagnosis system using on-line parameter identification. Besides these model based diagnostic schemes, there are still many failure modes which need to be diagnosed by the heuristic expert knowledge. The heuristic expert knowledge is implemented using a real-time expert system tool called G2 by Gensym Corp. Finally, the distributed diagnostic system requires another level of intelligence to oversee the fault mode reports generated by component fault detectors. The decision making at this level can best be done using a rule-based expert system. This level of expert knowledge is also implemented using G2.

  2. Process Diagnostics and Monitoring Using the Multipole Resonance Probe (MRP)

    NASA Astrophysics Data System (ADS)

    Harhausen, J.; Awakowicz, P.; Brinkmann, R. P.; Foest, R.; Lapke, M.; Musch, T.; Mussenbrock, T.; Oberrath, J.; Ohl, A.; Rolfes, I.; Schulz, Ch.; Storch, R.; Styrnoll, T.

    2011-10-01

    In this contribution we present the application of the MRP in an industrial plasma ion assisted deposition (PIAD) chamber (Leybold optics SYRUS-pro). The MRP is a novel plasma diagnostic which is suitable for an industrial environment - which means that the proposed method is robust, calibration free, and economical, and can be used for ideal and reactive plasmas alike. In order to employ the MRP as process diagnostics we mounted the probe on a manipulator to obtain spatially resolved information on the electron density and temperature. As monitoring tool the MRP is installed at a fixed position. Even during the deposition process it provides stable measurement results while other diagnostic methods, e.g. the Langmuir probe, may suffer from dielectric coatings. In this contribution we present the application of the MRP in an industrial plasma ion assisted deposition (PIAD) chamber (Leybold optics SYRUS-pro). The MRP is a novel plasma diagnostic which is suitable for an industrial environment - which means that the proposed method is robust, calibration free, and economical, and can be used for ideal and reactive plasmas alike. In order to employ the MRP as process diagnostics we mounted the probe on a manipulator to obtain spatially resolved information on the electron density and temperature. As monitoring tool the MRP is installed at a fixed position. Even during the deposition process it provides stable measurement results while other diagnostic methods, e.g. the Langmuir probe, may suffer from dielectric coatings. Funded by the German Ministry for Education and Research (BMBF, Fkz. 13N10462).

  3. 24 CFR 214.315 - Recordkeeping.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...'s personal and financial information, including credit reports, whether the information is received... client meets his or her housing need or resolves the housing problem; (2) The agency determines that further housing counseling will not meet the client's housing need or resolve the client's housing problem...

  4. Perspective: Whither the problem list? Organ-based documentation and deficient synthesis by medical trainees.

    PubMed

    Kaplan, Daniel M

    2010-10-01

    The author argues that the well-formulated problem list is essential for both organizing and evaluating diagnostic thinking. He considers evidence of deficiencies in problem lists in the medical record. He observes a trend among medical trainees toward organizing notes in the medical record according to lists of organ systems or medical subspecialties and hypothesizes that system-based documentation may undermine the art of problem formulation and diagnostic synthesis. Citing research linking more sophisticated problem representation with diagnostic success, he suggests that documentation style and clinical reasoning are closely connected and that organ-based documentation may predispose trainees to several varieties of cognitive diagnostic error and deficient synthesis. These include framing error, premature or absent closure, failure to integrate related findings, and failure to recognize the level of diagnostic resolution attained for a given problem. He acknowledges the pitfalls of higher-order diagnostic resolution, including the application of labels unsupported by firm evidence, while maintaining that diagnostic resolution as far as evidence permits is essential to both rational care of patients and rigorous education of learners. He proposes further research, including comparison of diagnostic efficiency between organ- and problem-oriented thinkers. He hypothesizes that the subspecialty-based structure of academic medical services helps perpetuate organ-system-based thinking, and calls on clinical educators to renew their emphasis on the formulation and documentation of complete and precise problem lists and progressively refined diagnoses by trainees.

  5. Substance dependence and non-dependence in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and the International Classification of Diseases (ICD): can an identical conceptualization be achieved?

    PubMed

    Saunders, John B

    2006-09-01

    This review summarizes the history of the development of diagnostic constructs that apply to repetitive substance use, and compares and contrasts the nature, psychometric performance and utility of the major diagnoses in the Diagnostic and Statistical Manual of Mental Disorders (DSM) and International Classification of Diseases (ICD) diagnostic systems. The available literature was reviewed with a particular focus on diagnostic concepts that are relevant for clinical and epidemiological practice, and so that research questions could be generated that might inform the development of the next generation of DSM and ICD diagnoses. The substance dependence syndrome is a psychometrically robust and clinically useful construct, which applies to a range of psychoactive substances. The differences between the DSM fourth edition (DSM-IV) and the ICD tenth edition (ICD-10) versions are minimal and could be resolved. DSM-IV substance abuse performs moderately well but, being defined essentially by social criteria, may be culture-dependent. ICD-10 harmful substance use performs poorly as a diagnostic entity. There are good prospects for resolving many of the differences between the DSM and ICD systems. A new non-dependence diagnosis is required. There would also be advantages in a subthreshold diagnosis of hazardous or risky substance use being incorporated into the two systems. Biomedical research can be drawn upon to define a psychophysiological 'driving force' which could underpin a broad spectrum of substance use disorders.

  6. Detector response function of an energy-resolved CdTe single photon counting detector.

    PubMed

    Liu, Xin; Lee, Hyoung Koo

    2014-01-01

    While spectral CT using single photon counting detector has shown a number of advantages in diagnostic imaging, knowledge of the detector response function of an energy-resolved detector is needed to correct the signal bias and reconstruct the image more accurately. The objective of this paper is to study the photo counting detector response function using laboratory sources, and investigate the signal bias correction method. Our approach is to model the detector response function over the entire diagnostic energy range (20 keV

  7. Prevalence, diagnostics and management of musculoskeletal disorders in primary health care in Sweden – an investigation of 2000 randomly selected patient records

    PubMed Central

    Fahlström, Martin; Djupsjöbacka, Mats

    2016-01-01

    Abstract Rationale, aims and objectives The aims of this study is to investigate the prevalence of patients seeking care due to different musculoskeletal disorders (MSDs) at primary health care centres (PHCs), to chart different factors such as symptoms, diagnosis and actions prescribed for patients that visited the PHCs due to MSD and to make comparisons regarding differences due to gender, age and rural or urban PHC. Methods Patient records (2000) for patients in working age were randomly selected equally distributed on one rural and one urban PHC. A 3‐year period was reviewed retrospectively. For all patient records' background data, cause to the visit and diagnosis were registered. For visits due to MSD, type and location of symptoms and actions to resolve the patients problems were registered. Data was analysed using cross tabulation, multidimensional chi‐squared. Results The prevalence of MSD was high; almost 60% of all patients were seeking care due to MSD. Upper and lower limb problems were most common. Symptoms were most prevalent in the young and middle age groups. The patients got a variety of different diagnoses, and between 13 and 35% of the patients did not receive a MSD diagnose despite having MSD symptoms. There was a great variation in how the cases were handled. Conclusions The present study points out some weaknesses regarding diagnostics and management of MSD in primary care. PMID:27538347

  8. Prevalence, diagnostics and management of musculoskeletal disorders in primary health care in Sweden - an investigation of 2000 randomly selected patient records.

    PubMed

    Wiitavaara, Birgitta; Fahlström, Martin; Djupsjöbacka, Mats

    2017-04-01

    The aims of this study is to investigate the prevalence of patients seeking care due to different musculoskeletal disorders (MSDs) at primary health care centres (PHCs), to chart different factors such as symptoms, diagnosis and actions prescribed for patients that visited the PHCs due to MSD and to make comparisons regarding differences due to gender, age and rural or urban PHC. Patient records (2000) for patients in working age were randomly selected equally distributed on one rural and one urban PHC. A 3-year period was reviewed retrospectively. For all patient records' background data, cause to the visit and diagnosis were registered. For visits due to MSD, type and location of symptoms and actions to resolve the patients problems were registered. Data was analysed using cross tabulation, multidimensional chi-squared. The prevalence of MSD was high; almost 60% of all patients were seeking care due to MSD. Upper and lower limb problems were most common. Symptoms were most prevalent in the young and middle age groups. The patients got a variety of different diagnoses, and between 13 and 35% of the patients did not receive a MSD diagnose despite having MSD symptoms. There was a great variation in how the cases were handled. The present study points out some weaknesses regarding diagnostics and management of MSD in primary care. © 2016 The Authors. Journal of Evaluation in Clinical Practice published by John Wiley & Sons, Ltd.

  9. 48 CFR 229.101 - Resolving tax problems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Resolving tax problems. 229.101 Section 229.101 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM...) Within DoD, the agency-designated legal counsels are the defense agency General Counsels, the General...

  10. Drug-related problems and pharmacist interventions in a cohort of patients with asthma and chronic obstructive pulmonary disease.

    PubMed

    Apikoglu-Rabus, Sule; Yesilyaprak, Gozde; Izzettin, Fikret Vehbi

    2016-11-01

    Asthma and chronic obstructive pulmonary disease are preventable and treatable chronic airway diseases with high incidence and prevalence. Pharmacists and clinical pharmacy based pharmaceutical care services have positive impact on therapy outcomes. The aim of this study is to describe drug related problems in a cohort of patients with asthma and chronic obstructive pulmonary disease and to assess interventions provided by the pharmacist to address these problems in a community pharmacy. Study population consisted of patients with asthma and chronic obstructive pulmonary disease older than 18 years who visited the study pharmacy during the pre-determined six-month period. The patients whose disease control states were "not fully controlled" were included in our study for further steps. On the first interview, present and potential drug related problems were addressed, interventions were provided. Follow-up interviews were held one month and two months later than the first interview. For the 44 patients with asthma, 59 drug-related problems and 134 causes for these problems were identified. Eighty-four interventions were made to resolve the problems; and 54.2% of the problems were resolved. For the 37 patients with chronic obstructive pulmonary disease, 60 drug-related problems and 128 causes for these problems were identified. Ninety-five interventions were made to resolve the problems; and 63.3% of the problems were resolved. Pharmacists taking part in therapy and management of asthma and chronic obstructive pulmonary disease can help patients be more educated about their disease and medications; and improve disease control and therapy outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Magnetic Resonance Angiography in the Diagnosis of Cerebral Arteriovenous Malformation and Dural Arteriovenous Fistulas: Comparison of Time-Resolved Magnetic Resonance Angiography and Three Dimensional Time-of-Flight Magnetic Resonance Angiography

    PubMed Central

    Cheng, Yu-Ching; Chen, Hung-Chieh; Wu, Chen-Hao; Wu, Yi-Ying; Sun, Ming-His; Chen, Wen-Hsien; Chai, Jyh-Wen; Chi-Chang Chen, Clayton

    2016-01-01

    Background Traditional digital subtraction angiography (DSA) is currently the gold standard diagnostic method for the diagnosis and evaluation of cerebral arteriovenous malformation (AVM) and dural arteriovenous fistulas (dAVF). Objectives The aim of this study was to analyze different less invasive magnetic resonance angiography (MRA) images, time-resolved MRA (TR-MRA) and three-dimensional time-of-flight MRA (3D TOF MRA) to identify their diagnostic accuracy and to determine which approach is most similar to DSA. Patients and Methods A total of 41 patients with AVM and dAVF at their initial evaluation or follow-up after treatment were recruited in this study. We applied time-resolved angiography using keyhole (4D-TRAK) MRA to perform TR-MRA and 3D TOF MRA examinations simultaneously followed by DSA, which was considered as a standard reference. Two experienced neuroradiologists reviewed the images to compare the diagnostic accuracy, arterial feeder and venous drainage between these two MRA images. Inter-observer agreement for different MRA images was assessed by Kappa coefficient and the differences of diagnostic accuracy between MRA images were evaluated by the Wilcoxon rank sum test. Results Almost all vascular lesions (92.68%) were correctly diagnosed using 4D-TRAK MRA. However, 3D TOF MRA only diagnosed 26 patients (63.41%) accurately. There were statistically significant differences regarding lesion diagnostic accuracy (P = 0.008) and venous drainage identification (P < 0.0001) between 4D-TRAK MRA and 3D TOF MRA. The results indicate that 4D-TRAK MRA is superior to 3D TOF MRA in the assessment of lesions. Conclusion Compared with 3D TOF MRA, 4D-TRAK MRA proved to be a more reliable screening modality and follow-up method for the diagnosis of cerebral AVM and dAVF. PMID:27679690

  12. Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tremsin, Anton S.; Perrodin, Didier; Losko, Adrian S.

    Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production.more » This technique is widely applicable and is not limited to crystal growth processes.« less

  13. Real-time Crystal Growth Visualization and Quantification by Energy-Resolved Neutron Imaging

    DOE PAGES

    Tremsin, Anton S.; Perrodin, Didier; Losko, Adrian S.; ...

    2017-04-20

    Energy-resolved neutron imaging is investigated as a real-time diagnostic tool for visualization and in-situ measurements of "blind" processes. This technique is demonstrated for the Bridgman-type crystal growth enabling remote and direct measurements of growth parameters crucial for process optimization. The location and shape of the interface between liquid and solid phases are monitored in real-time, concurrently with the measurement of elemental distribution within the growth volume and with the identification of structural features with a ~100 μm spatial resolution. Such diagnostics can substantially reduce the development time between exploratory small scale growth of new materials and their subsequent commercial production.more » This technique is widely applicable and is not limited to crystal growth processes.« less

  14. Rarefied flow diagnostics using pulsed high-current electron beams

    NASA Technical Reports Server (NTRS)

    Wojcik, Radoslaw M.; Schilling, John H.; Erwin, Daniel A.

    1990-01-01

    The use of high-current short-pulse electron beams in low-density gas flow diagnostics is introduced. Efficient beam propagation is demonstrated for pressure up to 300 microns. The beams, generated by low-pressure pseudospark discharges in helium, provide extremely high fluorescence levels, allowing time-resolved visualization in high-background environments. The fluorescence signal frequency is species-dependent, allowing instantaneous visualization of mixing flowfields.

  15. Time-resolved laser-induced fluorescence spectroscopy as a diagnostic instrument in head and neck carcinoma.

    PubMed

    Meier, Jeremy D; Xie, Hongtao; Sun, Yang; Sun, Yinghua; Hatami, Nisa; Poirier, Brian; Marcu, Laura; Farwell, D Gregory

    2010-06-01

    The objectives of this study were to 1) determine differences in lifetime fluorescence between normal and malignant tissue of the upper aerodigestive tract, and 2) evaluate the potential of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) as a diagnostic instrument for head and neck squamous cell carcinoma (HNSCC). Cross-sectional study. University-based medical center. Nine patients with suspected HNSCC were included. In the operating room, a nitrogen pulse laser (337 nm, 700-picosecond pulse width) was used to induce tissue autofluorescence of normal tissue and suspected malignant lesions. Spectral intensities and time-domain measurements were obtained and compared with the histopathology at each site. A total of 53 sites were measured. The fluorescence parameters that provided the most discrimination were determined. Differences in spectral intensities allowed for discrimination between malignant and normal tissue. The spectral intensity of malignant tissue was lower than that of normal tissue, and a shift of peak intensity to a longer wavelength was observed in the normalized spectrum of malignant tissue in the range of 360 to approximately 660 nm. Multiple time-resolved fluorescence parameters provided the best diagnostic discrimination between normal tissue and carcinoma, including average lifetimes (i.e., at 390 nm: 1.7 +/- 0.06 ns [not significant] for normal and 1.3 +/- 0.06 ns for tumor, P = 0.0025) and the second-order Laguerre expansion coefficient (LEC-2) (i.e., at 460 nm: 0.135 +/- 0.001 for normal and 0.155 +/- 0.007 for tumor, P < 0.05). These findings highlight some of the differences in lifetime fluorescence between normal and malignant tissue. TR-LIFS has potential as a noninvasive diagnostic technique for HNSCC. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  16. Time-resolved laser-induced fluorescence spectroscopy as a diagnostic instrument in head and neck carcinoma

    PubMed Central

    Meier, Jeremy D.; Xie, Hongtao; Sun, Yang; Sun, Yinghua; Hatami, Nisa; Poirier, Brian; Marcu, Laura; Farwell, D. Gregory

    2011-01-01

    OBJECTIVE 1) Determine differences in lifetime fluorescence between normal and malignant tissue of the upper aerodigestive tract. 2) Evaluate the potential of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) as a diagnostic instrument for head and neck squamous cell carcinoma (HNSCC). STUDY DESIGN Cross-sectional study. SETTING University-based medical center. SUBJECTS AND METHODS Nine patients with suspected HNSCC were included. In the operating room, a nitrogen pulse laser (337 nm, 700 ps pulse width) was used to induce tissue autofluorescence of normal tissue and suspected malignant lesions. Spectral intensities and time-domain measurements were obtained and compared to the histopathology at each site. A total of 53 sites were measured. The fluorescence parameters that provided the most discrimination were determined. RESULTS Differences in spectral intensities allowed for discrimination between malignant and normal tissue. The spectral intensity of malignant tissue was lower than the normal tissue, and a shift of peak intensity to a longer wavelength was observed in the normalized spectrum of malignant tissue in the range of 360~660 nm. Multiple time-resolved fluorescence parameters provided the best diagnostic discrimination between normal tissue and carcinoma, including average lifetimes (i.e., at 390 nm: 1.7±0.06 ns for normal and 1.3±0.06 ns for tumor, P=0.0025), and the Laguerre coefficients, LEC-2 (i.e., at 460 nm: 0.135±0.001 for normal and 0.155±0.007 for tumor, P<0.05). CONCLUSION These findings highlight some of the differences in lifetime fluorescence between normal and malignant tissue. TR-LIFS has potential as a non-invasive diagnostic technique for HNSCC. PMID:20493355

  17. Application of the space-resolving flux detector for radiation measurements from an octahedral-aperture spherical hohlraum

    NASA Astrophysics Data System (ADS)

    Xie, Xufei; Du, Huabing; Chen, Jinwen; Liu, Shenye; Li, Zhichao; Yang, Dong; Huang, Yunbao; Ren, Kuan; Hou, Lifei; Li, Sanwei; Guo, Liang; Jiang, Xiaohua; Huo, Wenyi; Chen, Yaohua; Ren, Guoli; Lan, Ke; Wang, Feng; Jiang, Shaoen; Ding, Yongkun

    2018-06-01

    Space-resolving flux detection is an important technique for the diagnostic of the radiation field within the hohlraum in inertial confinement fusion, especially for the radiation field diagnostic in the novel spherical hohlraum with octahedral six laser entrance holes (LEHs), where localized measurements are necessary for the discrimination of the radiation flux from different LEHs. A novel space-resolving flux detector (SRFD) is developed at the SG-III laser facility for the radiation flux measurement in the first campaign of the octahedral spherical hohlraum energetics experiment. The principle and configuration of the SRFD system is introduced. The radiation flux from the wall of a gas-filled octahedral spherical hohlraum is measured for the first time by placing the SRFD system at the equatorial position of the SG-III laser facility, aiming at the hohlraum wall through one of the six LEHs. The absolute radiation flux from the re-emission area on the hohlraum wall is measured, and good consistency is found between the experimental data and the calculated data from a three-dimensional view factor analysis.

  18. Demonstration of Resolving Urban Problems by Applying Smart Technology.

    NASA Astrophysics Data System (ADS)

    Kim, Y.

    2016-12-01

    Recently, movements to seek various alternatives are becoming more active around the world to resolve urban problems related to energy, water, a greenhouse gas, and disaster by utilizing smart technology system. The purpose of this study is to evaluate service verification aimed at demonstration region applied with actual smart technology in order to raise the efficiency of the service and explore solutions for urban problems. This process must be required for resolving urban problems in the future and establishing `integration platform' for sustainable development. The demonstration region selected in this study to evaluate service verification is `Busan' in Korea. Busan adopted 16 services in 4 sections last year and begun demonstration to improve quality of life and resolve urban environment problems. In addition, Busan participated officially in `Global City Teams Challenge (GCTC)' held by National Institute of Standards and Technology (NIST) in USA last year and can be regarded as representative demonstration region in Korea. The result of survey showed that there were practical difficulties as explained below in the demonstration for resolving urban problems by applying smart technology. First, the participation for demonstration was low because citizens were either not aware or did not realize the demonstration. Second, after demonstrating various services at low cost, it resulted in less effect of service demonstration. Third, as functions get fused, it was found that management department, application criteria of technology and its process were ambiguous. In order to increase the efficiency of the demonstration for the rest of period through the result of this study, it is required to draw demand that citizens requires in order to raise public participation. In addition, it needs to focus more on services which are wanted to demonstrate rather than various service demonstrations. Lastly, it is necessary to build integration platform through cooperation between departments and branches. The data collected from various source while conducting service demonstration will provide meaningful suggestion in order to explore solution for resolving urban problems by applying smart technology in the future.

  19. Recent experience in seeding transonic/supersonic flows at AEDC

    NASA Astrophysics Data System (ADS)

    Heltsley, F. L.

    1985-10-01

    The laser velocimeter has been utilized for several years at the Arnold Engineering and Development Center (AEDC) as a flow diagnostics tool. Most applications, following the initial proof-of-concept experiments, have involved relatively complex unknown flow fields in which the more conventional, intrusive techniques had either not been attempted or had yielded unsatisfactory results. A blunt-base nozzle-afterbody base flow study is discussed as a respresentative example of such applications. A wide variety of problems have been encountered during these tests, many of which have proven to be closely related to the size and/or size distribution of the seeding material within the fluid. Resulting measurement uncertainties could often not be conclusively resolved because of the unknown nature of the flow field. The other experiments listed were conducted to provide known aerodynamic conditions for comparison with the velocimeter results.

  20. Recent experience in seeding transonic/supersonic flows at AEDC

    NASA Technical Reports Server (NTRS)

    Heltsley, F. L.

    1985-01-01

    The laser velocimeter has been utilized for several years at the Arnold Engineering and Development Center (AEDC) as a flow diagnostics tool. Most applications, following the initial proof-of-concept experiments, have involved relatively complex unknown flow fields in which the more conventional, intrusive techniques had either not been attempted or had yielded unsatisfactory results. A blunt-base nozzle-afterbody base flow study is discussed as a respresentative example of such applications. A wide variety of problems have been encountered during these tests, many of which have proven to be closely related to the size and/or size distribution of the seeding material within the fluid. Resulting measurement uncertainties could often not be conclusively resolved because of the unknown nature of the flow field. The other experiments listed were conducted to provide known aerodynamic conditions for comparison with the velocimeter results.

  1. Community-acquired purulent meningitis of unknown etiology. A continuing problem.

    PubMed

    Geiseler, P J; Nelson, K E; Levin, S

    1981-12-01

    The clinical features and hospital course of 132 patients with purulent meningitis of unknown etiology (PMU) were compared with those of 1,032 patients with proven bacterial meningitis; all patients were admitted to a major referral center for meningitis treatment between 1954 and 1976. Most patients had no major underlying illnesses. Patients with PMU were more frequently older, "pretreated" with antibiotics, had longer duration of symptoms, evidenced less marked alterations of mental status, and died later in the hospitalization; however, the mortality and frequency of neurologic complications were similar to those in patients with bacterial meningitis. Patients with PMU who also had hemorrhagic rashes had fewer neurologic complications and none died; these patients comprised a distinct group in terms of better prognosis. New methods for rapid diagnosis of bacterial meningitis have only partially resolved the diagnostic dilemma of PMU.

  2. Strategies for laser-induced fluorescence detection of nitric oxide in high-pressure flames. II. A-X(0,1) excitation

    NASA Astrophysics Data System (ADS)

    Bessler, Wolfgang G.; Schulz, Christof; Lee, Tonghun; Jeffries, Jay B.; Hanson, Ronald K.

    2003-04-01

    A-X(0,1) excitation is a promising new approach for NO laser-induced fluorescence (LIF) diagnostics at elevated pressures and temperatures. We present what to our knowledge are the first detailed spectroscopic investigations within this excitation band using wavelength-resolved LIF measurements in premixed methane/air flames at pressures between 1 and 60 bar and a range of fuel/air ratios. Interference from O2 LIF is a significant problem in lean flames for NO LIF measurements, and pressure broadening and quenching lead to increased interference with increased pressure. Three different excitation schemes are identified that maximize NO/O2 LIF signal ratios, thereby minimizing the O2 interference. The NO LIF signal strength, interference by hot molecular oxygen, and temperature dependence of the three schemes are investigated.

  3. BRIEF COMMUNICATION: Calculation of a magnetic field effect on emission spectra of light diatomic molecules for diagnostic application to fusion edge plasmas

    NASA Astrophysics Data System (ADS)

    Shikama, T.; Fujii, K.; Mizushiri, K.; Hasuo, M.; Kado, S.; Zushi, H.

    2009-12-01

    A scheme for computation of emission spectra of light diatomic molecules under external magnetic and electric fields is presented. As model species in fusion edge plasmas, the scheme is applied to polarization-resolved emission spectra of H2, CH, C2, BH and BeH molecules. The possibility of performing spatially resolved measurements of these spectra is examined.

  4. Parallel, Asynchronous Executive (PAX): System concepts, facilities, and architecture

    NASA Technical Reports Server (NTRS)

    Jones, W. H.

    1983-01-01

    The Parallel, Asynchronous Executive (PAX) is a software operating system simulation that allows many computers to work on a single problem at the same time. PAX is currently implemented on a UNIVAC 1100/42 computer system. Independent UNIVAC runstreams are used to simulate independent computers. Data are shared among independent UNIVAC runstreams through shared mass-storage files. PAX has achieved the following: (1) applied several computing processes simultaneously to a single, logically unified problem; (2) resolved most parallel processor conflicts by careful work assignment; (3) resolved by means of worker requests to PAX all conflicts not resolved by work assignment; (4) provided fault isolation and recovery mechanisms to meet the problems of an actual parallel, asynchronous processing machine. Additionally, one real-life problem has been constructed for the PAX environment. This is CASPER, a collection of aerodynamic and structural dynamic problem simulation routines. CASPER is not discussed in this report except to provide examples of parallel-processing techniques.

  5. Characteristics of a Cognitive Tool That Helps Students Learn Diagnostic Problem Solving

    ERIC Educational Resources Information Center

    Danielson, Jared A.; Mills, Eric M.; Vermeer, Pamela J.; Preast, Vanessa A.; Young, Karen M.; Christopher, Mary M.; George, Jeanne W.; Wood, R. Darren; Bender, Holly S.

    2007-01-01

    Three related studies replicated and extended previous work (J.A. Danielson et al. (2003), "Educational Technology Research and Development," 51(3), 63-81) involving the Diagnostic Pathfinder (dP) (previously Problem List Generator [PLG]), a cognitive tool for learning diagnostic problem solving. In studies 1 and 2, groups of 126 and 113…

  6. SU-F-T-462: Lessons Learned From a Machine Incident Reporting System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutlief, S; Hoisak, J

    Purpose: Linear accelerators must operate with minimal downtime. Machine incident logs are a crucial tool to meet this requirement. They providing a history of service and demonstrate whether a fix is working. This study investigates the information content of a large department linear accelerator incident log. Methods: Our department uses an electronic reporting system to provide immediate information to both key department staff and the field service department. This study examines reports for five linac logs during 2015. The report attributes for analysis include frequency, level of documentation, who solved the problem, and type of fix used. Results: Of themore » reports, 36% were documented as resolved. In another 25% the resolution allowed treatment to proceed although the reported problem recurred within days. In 5% only intermediate troubleshooting was documented. The remainder lacked documentation. In 60% of the reports, radiation therapists resolved the problem, often by clearing the appropriate faults or reinitializing a software or hardware service. 22% were resolved by physics and 10% by field service engineers. The remaining 8% were resolved by IT, Facilities, or resolved spontaneously. Typical fixes, in order of scope, included clearing the fault and moving on, closing and re-opening the patient session or software, cycling power to a sub-unit, recalibrating a device (e.g., optical surface imaging), and calling in Field Service (usually resolving the problem through maintenance or component replacement). Conclusion: The reports with undocumented resolution represent a missed opportunity for learning. Frequency of who resolves a problem scales with the proximity of the person’s role (therapist, physicist, or service engineer), which is inversely related to the permanence of the resolution. Review of lessons learned from machine incident logs can form the basis for guidance to radiation therapists and medical physicists to minimize equipment downtime and ensure safe operation.« less

  7. Thermal conduction study of warm dense aluminum by proton differential heating

    NASA Astrophysics Data System (ADS)

    Ping, Y.; Kemp, G.; McKelvey, A.; Fernandez-Panella, A.; Shepherd, R.; Collins, G.; Sio, H.; King, J.; Freeman, R.; Hua, R.; McGuffey, C.; Kim, J.; Beg, F.

    2016-10-01

    A differential heating platform has been developed for thermal conduction study (Ping et al. PoP 2015), where a temperature gradient is induced and subsequent heat flow is probed by time-resolved diagnostics. An experiment using proton differential heating has been carried out at Titan laser for Au/Al targets. Two single-shot time-resolved diagnostics are employed, SOP (streaked optical pyrometry) for surface temperature and FDI (Fourier Domain Interferometry) for surface expansion. Hydrodynamic simulations show that after 15ps, absorption in underdense plasma needs to be taken into account to correctly interpret SOP data. Comparison between simulations with different thermal conductivity models and a set of data with varying target thickness will be presented. This work was performed under DOE contract DE-AC52-07NA27344 with support from OFES Early Career program and LLNL LDRD program.

  8. Bloody nipple discharge (BND) in an 8 months old girl and a 9 months old male--rational diagnostic approach.

    PubMed

    Harmsen, S; Mayatepek, E; Klee, D; Meissner, T

    2010-03-01

    Bloody nipple discharge in adults is, in men as well as in women, often a symptom of an underlying malignant disease. In respect of this, multiple invasive and mutilating diagnostic procedures have been performed in infants and older children. Apart from individual cases in older and pubertal children, in childhood benign conditions are most common and can be diagnosed by non-invasive diagnostic procedures. Here we discuss a rational diagnostic approach on the basis of 2 patients with bloody nipple discharge at the age of 8 and 9 months which resolved spontaneously without treatment after 3 and 6 months, respectively. (c) Georg Thieme Verlag KG Stuttgart-New York.

  9. Image quality enhancement for skin cancer optical diagnostics

    NASA Astrophysics Data System (ADS)

    Bliznuks, Dmitrijs; Kuzmina, Ilona; Bolocko, Katrina; Lihachev, Alexey

    2017-12-01

    The research presents image quality analysis and enhancement proposals in biophotonic area. The sources of image problems are reviewed and analyzed. The problems with most impact in biophotonic area are analyzed in terms of specific biophotonic task - skin cancer diagnostics. The results point out that main problem for skin cancer analysis is the skin illumination problems. Since it is often not possible to prevent illumination problems, the paper proposes image post processing algorithm - low frequency filtering. Practical results show diagnostic results improvement after using proposed filter. Along that, filter do not reduces diagnostic results' quality for images without illumination defects. Current filtering algorithm requires empirical tuning of filter parameters. Further work needed to test the algorithm in other biophotonic applications and propose automatic filter parameter selection.

  10. Exploration of CdTe quantum dots as mesoscale pressure sensors via time-resolved shock-compression photoluminescent emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Kang, Zhitao; Banishev, Alexandr A.; Lee, Gyuhyon; Scripka, David A.; Breidenich, Jennifer; Xiao, Pan; Christensen, James; Zhou, Min; Summers, Christopher J.; Dlott, Dana D.; Thadhani, Naresh N.

    2016-07-01

    The nanometer size of CdTe quantum dots (QDs) and their unique optical properties, including size-tunable narrow photoluminescent emission, broad absorption, fast photoluminescence decay, and negligible light scattering, are ideal features for spectrally tagging the shock response of localized regions in highly heterogeneous materials such as particulate media. In this work, the time-resolved laser-excited photoluminescence response of QDs to shock-compression was investigated to explore their utilization as mesoscale sensors for pressure measurements and in situ diagnostics during shock loading experiments. Laser-driven shock-compression experiments with steady-state shock pressures ranging from 2.0 to 13 GPa were performed on nanocomposite films of CdTe QDs dispersed in a soft polyvinyl alcohol polymer matrix and in a hard inorganic sodium silicate glass matrix. Time-resolved photoluminescent emission spectroscopy was used to correlate photoluminescence changes with the history of shock pressure and the dynamics of the matrix material surrounding the QDs. The results revealed pressure-induced blueshifts in emitted wavelength, decreases in photoluminescent emission intensity, reductions in peak width, and matrix-dependent response times. Data obtained for these QD response characteristics serve as indicators for their use as possible time-resolved diagnostics of the dynamic shock-compression response of matrix materials in which such QDs are embedded as in situ sensors.

  11. Exploration of CdTe quantum dots as mesoscale pressure sensors via time-resolved shock-compression photoluminescent emission spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Zhitao; School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0245; Banishev, Alexandr A.

    The nanometer size of CdTe quantum dots (QDs) and their unique optical properties, including size-tunable narrow photoluminescent emission, broad absorption, fast photoluminescence decay, and negligible light scattering, are ideal features for spectrally tagging the shock response of localized regions in highly heterogeneous materials such as particulate media. In this work, the time-resolved laser-excited photoluminescence response of QDs to shock-compression was investigated to explore their utilization as mesoscale sensors for pressure measurements and in situ diagnostics during shock loading experiments. Laser-driven shock-compression experiments with steady-state shock pressures ranging from 2.0 to 13 GPa were performed on nanocomposite films of CdTe QDs dispersedmore » in a soft polyvinyl alcohol polymer matrix and in a hard inorganic sodium silicate glass matrix. Time-resolved photoluminescent emission spectroscopy was used to correlate photoluminescence changes with the history of shock pressure and the dynamics of the matrix material surrounding the QDs. The results revealed pressure-induced blueshifts in emitted wavelength, decreases in photoluminescent emission intensity, reductions in peak width, and matrix-dependent response times. Data obtained for these QD response characteristics serve as indicators for their use as possible time-resolved diagnostics of the dynamic shock-compression response of matrix materials in which such QDs are embedded as in situ sensors.« less

  12. Retrospective analysis of the utility of multiparametric MRI for differentiating between benign and malignant breast lesions in women in China

    PubMed Central

    Fan, Wei Xiong; Chen, Xiao Feng; Cheng, Feng Yan; Cheng, Ya Bao; Xu, Tai; Zhu, Wen Biao; Zhu, Xiao Lei; Li, Gui Jin; Li, Shuai

    2018-01-01

    Abstract We explored the utility of time-resolved angiography with interleaved stochastic trajectories dynamic contrast-enhanced magnetic resonance imaging (TWIST DCE-MRI), readout segmentation of long variable echo-trains diffusion-weighted magnetic resonance imaging- diffusion-weighted magnetic resonance imaging (RESOLVE-DWI), and echo-planar imaging- diffusion-weighted magnetic resonance imaging (EPI-DWI) for distinguishing between malignant and benign breast lesions. This retrospective analysis included female patients with breast lesions seen at a single center in China between January 2016 and April 2016. Patients were allocated to a benign or malignant group based on pathologic diagnosis. All patients received routine MRI, RESOLVE-DWI, EPI-DWI, and TWIST DCE-T1WI. Variables measured included quantitative parameters (Ktrans, Kep, and Ve), semiquantitative parameters (rate of contrast enhancement for contrast agent inflow [W-in], rate of contrast decay for contrast agent outflow [W-out], and time-to-peak enhancement after contrast agent injection [TTP]) and apparent diffusion coefficient (ADC) values for RESOLVE-DWI (ADCr) and EPI-DWI (ADCe). Receiver-operating characteristic (ROC) curve analysis was used to evaluate the diagnostic utility of each parameter for differentiating malignant from benign breast lesions. A total of 87 patients were included (benign, n = 20; malignant, n = 67). Compared with the benign group, the malignant group had significantly higher Ktrans, Kep and W-in and significantly lower W-out, TTP, ADCe, and ADCr (all P < .05); Ve was not significantly different between groups. RESOLVE-DWI was superior to conventional EPI-DWI at illustrating lesion boundary and morphology, while ADCr was significantly lower than ADCe in all patients. Kep, W-out, ADCr, and ADCe showed the highest diagnostic efficiency (based on AUC value) for differentiating between benign and malignant lesions. Combining 3 parameters (Kep, W-out, and ADCr) had a higher diagnostic efficiency (AUC, 0.965) than any individual parameter and distinguished between benign and malignant lesions with high sensitivity (91.0%), specificity (95.0%), and accuracy (91.9%). An index combining Kep, W-out, and ADCr could potentially be used for the differential diagnosis of breast lesions. PMID:29369183

  13. Retrospective analysis of the utility of multiparametric MRI for differentiating between benign and malignant breast lesions in women in China.

    PubMed

    Fan, Wei Xiong; Chen, Xiao Feng; Cheng, Feng Yan; Cheng, Ya Bao; Xu, Tai; Zhu, Wen Biao; Zhu, Xiao Lei; Li, Gui Jin; Li, Shuai

    2018-01-01

    We explored the utility of time-resolved angiography with interleaved stochastic trajectories dynamic contrast-enhanced magnetic resonance imaging (TWIST DCE-MRI), readout segmentation of long variable echo-trains diffusion-weighted magnetic resonance imaging- diffusion-weighted magnetic resonance imaging (RESOLVE-DWI), and echo-planar imaging- diffusion-weighted magnetic resonance imaging (EPI-DWI) for distinguishing between malignant and benign breast lesions.This retrospective analysis included female patients with breast lesions seen at a single center in China between January 2016 and April 2016. Patients were allocated to a benign or malignant group based on pathologic diagnosis. All patients received routine MRI, RESOLVE-DWI, EPI-DWI, and TWIST DCE-T1WI. Variables measured included quantitative parameters (K, Kep, and Ve), semiquantitative parameters (rate of contrast enhancement for contrast agent inflow [W-in], rate of contrast decay for contrast agent outflow [W-out], and time-to-peak enhancement after contrast agent injection [TTP]) and apparent diffusion coefficient (ADC) values for RESOLVE-DWI (ADCr) and EPI-DWI (ADCe). Receiver-operating characteristic (ROC) curve analysis was used to evaluate the diagnostic utility of each parameter for differentiating malignant from benign breast lesions.A total of 87 patients were included (benign, n = 20; malignant, n = 67). Compared with the benign group, the malignant group had significantly higher K, Kep and W-in and significantly lower W-out, TTP, ADCe, and ADCr (all P < .05); Ve was not significantly different between groups. RESOLVE-DWI was superior to conventional EPI-DWI at illustrating lesion boundary and morphology, while ADCr was significantly lower than ADCe in all patients. Kep, W-out, ADCr, and ADCe showed the highest diagnostic efficiency (based on AUC value) for differentiating between benign and malignant lesions. Combining 3 parameters (Kep, W-out, and ADCr) had a higher diagnostic efficiency (AUC, 0.965) than any individual parameter and distinguished between benign and malignant lesions with high sensitivity (91.0%), specificity (95.0%), and accuracy (91.9%).An index combining Kep, W-out, and ADCr could potentially be used for the differential diagnosis of breast lesions.

  14. High density plasmas and new diagnostics: An overview (invited).

    PubMed

    Celona, L; Gammino, S; Mascali, D

    2016-02-01

    One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including "volume-integrated" X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a "pin-hole camera" has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

  15. A connectionist model for diagnostic problem solving

    NASA Technical Reports Server (NTRS)

    Peng, Yun; Reggia, James A.

    1989-01-01

    A competition-based connectionist model for solving diagnostic problems is described. The problems considered are computationally difficult in that (1) multiple disorders may occur simultaneously and (2) a global optimum in the space exponential to the total number of possible disorders is sought as a solution. The diagnostic problem is treated as a nonlinear optimization problem, and global optimization criteria are decomposed into local criteria governing node activation updating in the connectionist model. Nodes representing disorders compete with each other to account for each individual manifestation, yet complement each other to account for all manifestations through parallel node interactions. When equilibrium is reached, the network settles into a locally optimal state. Three randomly generated examples of diagnostic problems, each of which has 1024 cases, were tested, and the decomposition plus competition plus resettling approach yielded very high accuracy.

  16. Diagnostics for the detection and evaluation of laser induced damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheehan, L.; Kozlowski, M.; Rainer, F.

    1995-12-31

    The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less

  17. Diagnostics for the detection and evaluation of laser induced damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheehan, L.; Kozlowski, M.; Rainer, F.

    1995-01-03

    The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less

  18. The scientific status of childhood dissociative identity disorder: a review of published research.

    PubMed

    Boysen, Guy A

    2011-01-01

    Dissociative identity disorder (DID) remains a controversial diagnosis due to conflicting views on its etiology. Some attribute DID to childhood trauma and others attribute it to iatrogenesis. The purpose of this article is to review the published cases of childhood DID in order to evaluate its scientific status, and to answer research questions related to the etiological models. I searched MEDLINE and PsycINFO records for studies published since 1980 on DID/multiple personality disorder in children. For each study I coded information regarding the origin of samples and diagnostic methods. The review produced a total of 255 cases of childhood DID reported as individual case studies (44) or aggregated into empirical studies (211). Nearly all cases (93%) emerged from samples of children in treatment, and multiple personalities was the presenting problem in 23% of the case studies. Four US research groups accounted for 65% of all 255 cases. Diagnostic methods typically included clinical evaluation based on Diagnostic and Statistical Manual of Mental Disorder criteria, but hypnosis, structured interviews, and multiple raters were rarely used in diagnoses. Despite continuing research on the related concepts of trauma and dissociation, childhood DID itself appears to be an extremely rare phenomenon that few researchers have studied in depth. Nearly all of the research that does exist on childhood DID is from the 1980s and 1990s and does not resolve the ongoing controversies surrounding the disorder. Copyright © 2011 S. Karger AG, Basel.

  19. Interference-free optical detection for Raman spectroscopy

    NASA Technical Reports Server (NTRS)

    Fischer, David G (Inventor); Kojima, Jun (Inventor); Nguyen, Quang-Viet (Inventor)

    2012-01-01

    An architecture for spontaneous Raman scattering (SRS) that utilizes a frame-transfer charge-coupled device (CCD) sensor operating in a subframe burst gating mode to realize time-resolved combustion diagnostics is disclosed. The technique permits all-electronic optical gating with microsecond shutter speeds (<5 .mu.s), without compromising optical throughput or image fidelity. When used in conjunction with a pair of orthogonally-polarized excitation lasers, the technique measures time-resolved vibrational Raman scattering that is minimally contaminated by problematic optical background noise.

  20. Space-time resolving vacuum ultraviolet spectrometer based on a rotating polyhedral mirror

    NASA Astrophysics Data System (ADS)

    Lin, Xiaodong; Xie, Jikang

    2000-05-01

    Using a rotating polyhedral mirror and a vacuum ultraviolet (VUV) monochromater, a space-time resolving VUV diagnostic system is developed. Measurement of the O VI (103.2 nm) radiation on the HT-6M tokamak shows that the time resolution of the system is better than 4 ms and the space resolution is better than 2 cm. Compared with traditional instruments, this system has improved measurement efficiency, and error from shot-to-shot discharge variations is avoided.

  1. Diagnostics vehicle’s condition using obd-ii and raspberry pi technology: study literature

    NASA Astrophysics Data System (ADS)

    Moniaga, J. V.; Manalu, S. R.; Hadipurnawan, D. A.; Sahidi, F.

    2018-03-01

    Transportation accident rate are still being a major challenge in many countries. There are many factors that could be cause transportation accident, especially in vehicle’s internal system problem. To overcome this problem, OBD-II technology has been created to diagnostics vehicle’s condition. OBD-II scanner plugged to OBD-II port or usually called Data Link Connector (DLC), and after that it sends the diagnostics to Raspberry Pi. Compared from another microcontrollers, Arduino, Raspberry Pi are chosen because it sustains the application to receive real-time diagnostics, process the diagnostics and send command to automobiles at the same time, rather than Arduino that must wait for another process finished to run another process. Outcome from this application is to enable automobile’s user to diagnostics their own vehicles. If there is found something unusual or a problem, the application can told the problem to user, so they could know what to fix before they use their vehicle safely.

  2. The Galileo PPS expert monitoring and diagnostic prototype

    NASA Technical Reports Server (NTRS)

    Bahrami, Khosrow

    1989-01-01

    The Galileo PPS Expert Monitoring Module (EMM) is a prototype system implemented on the SUN workstation that will demonstrate a knowledge-based approach to monitoring and diagnosis for the Galileo spacecraft Power/Pyro subsystems. The prototype will simulate an analysis module functioning within the SFOC Engineering Analysis Subsystem Environment (EASE). This document describes the implementation of a prototype EMM for the Galileo spacecraft Power Pyro Subsystem. Section 2 of this document provides an overview of the issues in monitoring and diagnosis and comparison between traditional and knowledge-based solutions to this problem. Section 3 describes various tradeoffs which must be considered when designing a knowledge-based approach to monitoring and diagnosis, and section 4 discusses how these issues were resolved in constructing the prototype. Section 5 presents conclusions and recommendations for constructing a full-scale demonstration of the EMM. A Glossary provides definitions of terms used in this text.

  3. Primary obturator externus pyomyositis in a child presenting as hip pain: a case report.

    PubMed

    Kumar, Abhishek; Anderson, David

    2008-02-01

    Hip pain in children often poses a diagnostic dilemma. Septic arthritis, Perthes disease, and slipped capital femoral epiphysis are among the most important causes. Pyomyositis involving muscles around the hip can present with similar features as septic arthritis and are difficult to diagnose because of their rarity and indolent presentation. Obturator internus and iliopsoas muscle abscess have been most commonly reported, with only 1 such report on isolated obturator externus muscle abscess. Routine laboratory investigations are nonspecific, and the diagnosis rests on imaging modalities. Magnetic resonance scan is the most useful investigation in the diagnosis and can pick up early changes in the muscle. Treatment involves appropriate antibiotic therapy with or without drainage. Most cases resolve completely. We report here a case of isolated obturator externus muscle abscess in an 11-year-old child illustrating the similarities with septic arthritis of hip and problems encountered during diagnosis and management.

  4. Near surface IP investigations: Four case studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hearst, R.B.; Morris, W.A.; Clark, M.A.

    1995-12-31

    The use of the Induced Polarisation (IP) method of geophysical surveying for near surface site investigations is gaining acceptance within the geophysical community. In this study the IP method is evaluated as a tool for the delineation of ground water resources; contamination plume detection in a lateritic horizon; and acid mine drainage leak detection from decommissioned mine tailings. A time domain IP system was selected for this study primarily for the flexibility in the selection and setting of receiver time windows and diagnostic characteristics attributed to submitting the data to Cole-Cole analysis. Analysis of the acquired data in conjunction withmore » available borehole and geological information illustrates the effectiveness and usefulness of the survey method for solving near surface problems. In all of the locations tested, it was found that with a properly designed IP survey it was possible to resolve the target and/or related structures.« less

  5. High-speed laser anemometry based on spectrally resolved Rayleigh scattering

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard G.

    1991-01-01

    Laser anemometry in unseeded flows based on the measurement of the spectrum of Rayleigh scattered laser light is reviewed. The use of molecular scattering avoids the well known problems (particle lag, biasing effects, seed generation, seed injection) of seeded flows. The fundamental limits on velocity measurement accuracy are determined using maximum likelihood methods. Measurement of the Rayleigh spectrum with scanning Fabry-Perot interferometers is analyzed and accuracy limits are established for both single pass and multipass configurations. Multipass configurations have much higher selectivity and are needed for measurements where there is a large amount of excess noise caused by stray laser light. It is shown that Rayleigh scattering is particularly useful for supersonic and hypersonic flows. The results of the analysis are compared with measurements obtained with a Rayleigh scattering diagnostic developed for study of the exhaust plume of a small hydrogen-oxygen rocket, where the velocities are in the range of 1000 to 5000 m/sec.

  6. Evidence-informed recommendations to reduce dissemination bias in clinical research: conclusions from the OPEN (Overcome failure to Publish nEgative fiNdings) project based on an international consensus meeting

    PubMed Central

    Meerpohl, Joerg J; Schell, Lisa K; Bassler, Dirk; Gallus, Silvano; Kleijnen, Jos; Kulig, Michael; La Vecchia, Carlo; Marušić, Ana; Ravaud, Philippe; Reis, Andreas; Schmucker, Christine; Strech, Daniel; Urrútia, Gerard; Antes, Gerd

    2015-01-01

    Background Dissemination bias in clinical research severely impedes informed decision-making not only for healthcare professionals and patients, but also for funders, research ethics committees, regulatory bodies and other stakeholder groups that make health-related decisions. Decisions based on incomplete and biased evidence cannot only harm people, but may also have huge financial implications by wasting resources on ineffective or harmful diagnostic and therapeutic measures, and unnecessary research. Owing to involvement of multiple stakeholders, it remains easy for any single group to assign responsibility for resolving the problem to others. Objective To develop evidence-informed general and targeted recommendations addressing the various stakeholders involved in knowledge generation and dissemination to help overcome the problem of dissemination bias on the basis of previously collated evidence. Methods Based on findings from systematic reviews, document analyses and surveys, we developed general and targeted draft recommendations. During a 2-day workshop in summer 2013, these draft recommendations were discussed with external experts and key stakeholders, and refined following a rigorous and transparent methodological approach. Results Four general, overarching recommendations applicable to all or most stakeholder groups were formulated, addressing (1) awareness raising, (2) implementation of targeted recommendations, (3) trial registration and results posting, and (4) systematic approaches to evidence synthesis. These general recommendations are complemented and specified by 47 targeted recommendations tailored towards funding agencies, pharmaceutical and device companies, research institutions, researchers (systematic reviewers and trialists), research ethics committees, trial registries, journal editors and publishers, regulatory agencies, benefit (health technology) assessment institutions and legislators. Conclusions Despite various recent examples of dissemination bias and several initiatives to reduce it, the problem of dissemination bias has not been resolved. Tailored recommendations based on a comprehensive approach will hopefully help increase transparency in biomedical research by overcoming the failure to disseminate negative findings. PMID:25943371

  7. Patient navigation and time to diagnostic resolution: results for a cluster randomized trial evaluating the efficacy of patient navigation among patients with breast cancer screening abnormalities, Tampa, FL.

    PubMed

    Lee, Ji-Hyun; Fulp, William; Wells, Kristen J; Meade, Cathy D; Calcano, Ercilia; Roetzheim, Richard

    2013-01-01

    The objective of this study was to evaluate a patient navigation (PN) program that attempts to reduce the time between a breast cancer screening abnormality and definitive diagnosis among medically underserved populations of Tampa Bay, Florida. The Moffitt Patient Navigation Research Program conducted a cluster randomized design with 10 primary care clinics. Patients were navigated from time of a breast screening abnormality to diagnostic resolution. This paper examined the length of time between breast abnormality and definitive diagnosis, using a shared frailty Cox proportional hazard model to assess PN program effect. 1,039 patients were eligible for the study because of an abnormal breast cancer screening/clinical abnormality (494 navigated; 545 control). Analysis of PN effect by two time periods of resolution (0-3 months and > 3 months) showed a lagged effect of PN. For patients resolving in the first three months, the adjusted Hazard Ratio (aHR) was 0.85 (95% Confidence Interval [CI]: 0.64-1.13) suggesting that PN had no effect on resolution time during this period. Beyond three months, however, navigated patients resolved more quickly to diagnostic resolution compared with the control group (aHR 2.8, 95%CI: 1.30-6.13). The predicted aHR at 3 months was 1.2, which was not statistically significant, while PN had a significant positive effect beyond 4.7 months. PN programs may increase the timeliness of diagnostic resolution for patients with a breast cancer-related abnormality. PN did not speed diagnostic resolution during the initial three months of follow up but started to reduce time to diagnostic resolution after three months and showed a significant effect after 4.7 months. ClinicalTrials.gov NCT00375024.

  8. Diagnostic accuracy, risk assessment, and cost-effectiveness of component-resolved diagnostics for food allergy: A systematic review.

    PubMed

    Flores Kim, J; McCleary, N; Nwaru, B I; Stoddart, A; Sheikh, A

    2018-01-10

    Component-resolved diagnostics (CRD) are promising tools for diagnosing food allergy, offering the potential to determine specific phenotypes and to develop patient-tailored risk profiles. Nevertheless, the diagnostic accuracy of these tests varies across studies; thus, their clinical utility remains unclear. Therefore, we synthesized the evidence from studies investigating the diagnostic accuracy, risk assessment ability, and cost-effectiveness of CRD for food allergy. We systematically searched 10 electronic databases and four clinical trial registries for studies published from January 2000 to February 2017. The quality of included studies was assessed using QUADAS-2. Due to heterogeneity, we narratively synthesized the evidence. Eleven studies met inclusion criteria, altogether recruiting 1098 participants. The food allergies investigated were cow's milk, hen's egg, peanut, hazelnut, and shrimp. The components with the highest diagnostic accuracy for each allergen, along with their sensitivity-specificity pairs, were as follows: Bos d 4 for cow's milk (62.0% and 87.5%), Gal d 1 for hen's egg (84.2% and 89.8% for heated egg, and 60.6% and 97.1% for raw egg), Ara h 6 for peanut (94.9% and 95.1%), Cor a 14 for hazelnut (100% and 93.8%), and Lit v 1 for shrimp (82.8% and 56.3%) allergy. Selected components of cow's milk, hen's egg, peanut, hazelnut, and shrimp allergen showed high specificity, but lower sensitivity. However, few studies exist for each component, and studies vary widely regarding the cutoff values used, making it challenging to synthesize findings across studies. Further research is needed to determine clinically appropriate cutoff values, risk assessment abilities, and cost-effectiveness of CRD approaches. © 2018 The Authors. Allergy Published by John Wiley & Sons Ltd.

  9. Optical diagnostics of turbulent mixing in explosively-driven shock tube

    NASA Astrophysics Data System (ADS)

    Anderson, James; Hargather, Michael

    2016-11-01

    Explosively-driven shock tube experiments were performed to investigate the turbulent mixing of explosive product gases and ambient air. A small detonator initiated Al / I2O5 thermite, which produced a shock wave and expanding product gases. Schlieren and imaging spectroscopy were applied simultaneously along a common optical path to identify correlations between turbulent structures and spatially-resolved absorbance. The schlieren imaging identifies flow features including shock waves and turbulent structures while the imaging spectroscopy identifies regions of iodine gas presence in the product gases. Pressure transducers located before and after the optical diagnostic section measure time-resolved pressure. Shock speed is measured from tracking the leading edge of the shockwave in the schlieren images and from the pressure transducers. The turbulent mixing characteristics were determined using digital image processing. Results show changes in shock speed, product gas propagation, and species concentrations for varied explosive charge mass. Funded by DTRA Grant HDTRA1-14-1-0070.

  10. Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

    NASA Astrophysics Data System (ADS)

    Foley, E. L.; Levinton, F. M.

    2013-04-01

    The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

  11. Moving from Professionally Specific Ideals to the Common Morality: Essential Content in Social Work Ethics Education

    ERIC Educational Resources Information Center

    Bryan, Valerie

    2006-01-01

    A framework for resolving social work's ethical problems must allow for explicit discussion and justification (Osmo and Landau 2001). As opposed to a preoccupation with what "ought to be," it is argued that "what ought "not"" be" is the more useful question to ask when resolving a moral problem. The University of…

  12. Lessons Worth Remembering: Combat In Urban Areas

    DTIC Science & Technology

    2016-05-10

    areas, realize that indigenous groups are best at resolving local problems, accept operating decentralized, and value the importance of supreme firepower...that foments within urban areas, realize that indigenous groups are best at resolving local problems, accept operating decentralized, and value the...permeated stability throughout Ramadi. Second, 1BCT transitioned areas of responsibility to a competent and capable indigenous force to maintain the

  13. Ideational conflict: the key to promoting creative activity in the workplace.

    PubMed

    Dagostino, Lorraine

    1999-01-01

    This article defines the concept of ideational conflict as it applies to the process of identifying a problem and developing a plan of action for resolving the problem. Then the article examines and illustrates how the ideational conflict that is generated by brainstorming can lead to creative thinking that resolves disparate points of view. The illustration extends the generally accepted view of brainstorming and applies it to identifying a problem related to the university/college work environment. The problem situation is that of the loss of high ability faculty and sutdents to other institutions.

  14. Approximate relationship between frequency-dependent skin depth resolved from geoelectromagnetic pedotransfer function and depth of investigation resolved from geoelectrical measurements: A case study of coastal formation, southern Nigeria

    NASA Astrophysics Data System (ADS)

    George, N. J.; Obiora, D. N.; Ekanem, A. M.; Akpan, A. E.

    2016-10-01

    The task involved in the interpretation of Vertical Electrical Sounding (VES) data is how to get unique results in the absence/limited number of borehole information, which is usually limited to information on the spot. Geological and geochemical mapping of electrical properties are usually limited to direct observations on the surface and therefore, conclusions and extrapolations that can be drawn about the system electrical characteristics and possible underlying structures may be masked as geology changes with positions. The electrical resistivity study pedotransfer functions (PTFs) have been linked with the electromagnetic (EM) resolved PTFs at chosen frequencies of skin/penetration depth corresponding to the VES resolved investigation depth in order to determine the local geological attributes of hydrogeological repository in the coastal formation dominated with fine sand. The illustrative application of effective skin depth depicts that effective skin depth has direct relation with the EM response of the local source over the layered earth and thus, can be linked to the direct current earth response functions as an aid for estimating the optimum depth and electrical parameters through comparative analysis. Though the VES and EM resolved depths of investigation at appropriate effective and theoretical frequencies have wide gaps, diagnostic relations characterising the subsurface depth of interest have been established. The determining factors of skin effect have been found to include frequency/period, resistivity/conductivity, absorption/attenuation coefficient and energy loss factor. The novel diagnostic relations and their corresponding constants between 1-D resistivity data and EM skin depth are robust PTFs necessary for checking the accuracy associated with the non-unique interpretations that characterise the 1-D resistivity data, mostly when lithostratigraphic data are not available.

  15. Measurements of the principal Hugoniots of dense gaseous deuterium-helium mixtures: Combined multi-channel optical pyrometry, velocity interferometry, and streak optical pyrometry measurements

    NASA Astrophysics Data System (ADS)

    Li, Zhi-Guo; Chen, Qi-Feng; Gu, Yun-Jun; Zheng, Jun; Chen, Xiang-Rong

    2016-10-01

    The accurate hydrodynamic description of an event or system that addresses the equations of state, phase transitions, dissociations, ionizations, and compressions, determines how materials respond to a wide range of physical environments. To understand dense matter behavior in extreme conditions requires the continual development of diagnostic methods for accurate measurements of the physical parameters. Here, we present a comprehensive diagnostic technique that comprises optical pyrometry, velocity interferometry, and time-resolved spectroscopy. This technique was applied to shock compression experiments of dense gaseous deuterium-helium mixtures driven via a two-stage light gas gun. The advantage of this approach lies in providing measurements of multiple physical parameters in a single experiment, such as light radiation histories, particle velocity profiles, and time-resolved spectra, which enables simultaneous measurements of shock velocity, particle velocity, pressure, density, and temperature and expands understanding of dense high pressure shock situations. The combination of multiple diagnostics also allows different experimental observables to be measured and cross-checked. Additionally, it implements an accurate measurement of the principal Hugoniots of deuterium-helium mixtures, which provides a benchmark for the impedance matching measurement technique.

  16. Dual-focus versus conventional magnification endoscopy for the diagnosis of superficial squamous neoplasms in the pharynx and esophagus: a randomized trial.

    PubMed

    Goda, Kenichi; Dobashi, Akira; Yoshimura, Noboru; Aihara, Hiroyuki; Kato, Masayuki; Sumiyama, Kazuki; Toyoizumi, Hirobumi; Kato, Tomohiro; Saijo, Hiroki; Ikegami, Masahiro; Tajiri, Hisao

    2016-04-01

    Conventional magnification narrow-band imaging (CM-NBI) endoscopy has demonstrated high diagnostic accuracy for superficial squamous neoplasms in the pharynx and esophagus. This study aimed to evaluate the diagnostic utility of the newly developed dual-focus NBI (DF-NBI) compared with that of CM-NBI. We recruited patients with squamous cell carcinoma (SCC) in the head and neck, or esophagus, or with a history of SCC. The primary endpoint of this prospective controlled non-inferiority trial was the sensitivity of DF-NBI and CM-NBI for detecting superficial carcinoma in the pharynx and esophagus. Secondary endpoints included other diagnostic values and the resolving power of each endoscope. Superficial carcinoma was defined as high grade dysplasia and SCC invading up to the submucosal layer. The study included 93 patients. A total of 28 superficial carcinomas were detected in the pharynx and esophagus. The sensitivities of DF-NBI and CM-NBI for superficial carcinoma were 82 % and 71 %, respectively. The lower limit of the 90 % confidence interval for the difference between the sensitivities exceeded the non-inferiority threshold. The specificity and overall accuracy of DF-NBI vs. CM-NBI were 93 % vs. 90 % and 91 % vs. 86 %, respectively (both non-significant differences). The maximum resolving power of a conventional magnification endoscope was significantly higher than a dual-focus endoscope (7.2 µm vs. 11.6 µm: P < 0.001). The findings indicate the non-inferiority of DF-NBI versus CM-NBI in detecting superficial carcinoma in the pharynx and esophagus. DF-NBI appears to have a resolving power that, although significantly lower, is sufficient to achieve high diagnostic accuracy, comparable to that of CM-NBI.University Hospital Medical Information Network (UMIN, No. 000007585). © Georg Thieme Verlag KG Stuttgart · New York.

  17. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    NASA Astrophysics Data System (ADS)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  18. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography.

    PubMed

    Zhang, Tao; Yousaf, Ufra; Hsiao, Albert; Cheng, Joseph Y; Alley, Marcus T; Lustig, Michael; Pauly, John M; Vasanawala, Shreyas S

    2015-10-01

    Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography method for depicting abdominal arterial anatomy in young children. With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast-enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast-enhanced MR angiography studies. A radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9-5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries in young children.

  19. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes.

    PubMed

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ∼400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  20. An evaluation of independent consumer assistance centers on problem resolution and user satisfaction: the consumer perspective.

    PubMed

    Nascimento, Lori Miller; Cousineau, Michael R

    2005-04-01

    Individuals who wish to receive independent assistance to resolve access to care health problems have limited options. The Health Consumer Alliance (HCA) is an independent, coordinated effort of nine legal services organizations that provide free assistance to low-income health consumers in 10 California counties. The need for the HCA stems from the vast number of health consumers with unanswered questions and unresolved problems relating to access to care issues, among both insured and uninsured populations. However, little is known about the effectiveness of independent consumer assistance centers. This paper examines the effectiveness of a network of independent consumer assistance programs in resolving consumer problems and consumers' level of satisfaction with services received. As the project evaluators, we conducted telephone surveys with 1,291 users of the HCA to assess if this independent program resolved consumer problems, and to measure the level of satisfaction among HCA users. Specifically, we asked questions about the HCA's influence on problem resolution, consumer satisfaction, health insurance status and use of preventive care services. From 1997 to 2001, more than 46,000 consumers contacted the seven health consumer centers (HCCs). According to our sample of respondents, results show that the HCCs are an important resource for low-income Californians trying to access health care. After contacting the HCCs, 62 percent of the participants report that their problems were resolved. In addition, 87 percent of the participants said the HCCs were helpful and 95 percent said they would be likely to contact the HCC again if necessary.

  1. Quantitative characterization of steady and time-varying, sooting, laminar diffusion flames using optical techniques

    NASA Astrophysics Data System (ADS)

    Connelly, Blair C.

    In order to reduce the emission of pollutants such as soot and NO x from combustion systems, a detailed understanding of pollutant formation is required. In addition to environmental concerns, this is important for a fundamental understanding of flame behavior as significant quantities of soot lower local flame temperatures, increase overall flame length and affect the formation of such temperature-dependent species as NOx. This problem is investigated by carrying out coupled computational and experimental studies of steady and time-varying sooting, coflow diffusion flames. Optical diagnostic techniques are a powerful tool for characterizing combustion systems, as they provide a noninvasive method of probing the environment. Laser diagnostic techniques have added advantages, as systems can be probed with high spectral, temporal and spatial resolution, and with species selectivity. Experimental soot volume fractions were determined by using two-dimensional laser-induced incandescence (LII), calibrated with an on-line extinction measurement, and soot pyrometry. Measurements of soot particle size distributions are made using time-resolved LII (TR-LII). Laser-induced fluorescence measurements are made of NO and formaldehyde. These experimental measurements, and others, are compared with computational results in an effort to understand and model soot formation and to examine the coupled relationship of soot and NO x formation.

  2. Resolvent-Techniques for Multiple Exercise Problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, Sören, E-mail: christensen@math.uni-kiel.de; Lempa, Jukka, E-mail: jukka.lempa@hioa.no

    2015-02-15

    We study optimal multiple stopping of strong Markov processes with random refraction periods. The refraction periods are assumed to be exponentially distributed with a common rate and independent of the underlying dynamics. Our main tool is using the resolvent operator. In the first part, we reduce infinite stopping problems to ordinary ones in a general strong Markov setting. This leads to explicit solutions for wide classes of such problems. Starting from this result, we analyze problems with finitely many exercise rights and explain solution methods for some classes of problems with underlying Lévy and diffusion processes, where the optimal characteristicsmore » of the problems can be identified more explicitly. We illustrate the main results with explicit examples.« less

  3. Raising a Thinking Child: Help Your Young Child To Resolve Everyday Conflicts and Get Along with Others. First Edition.

    ERIC Educational Resources Information Center

    Shure, Myrna B.; DiGeronimo, Theresa Foy

    Based upon the principles of "I Can Problem Solve" (ICPS), this books offers parents dialogues, activities, and communication techniques to teach their children how to resolve day-to-day conflicts with friends, teachers, and family members. The book provides parents with tools to teach their children how to think about everyday problems and…

  4. Recent improvements of the JET lithium beam diagnostica)

    NASA Astrophysics Data System (ADS)

    Brix, M.; Dodt, D.; Dunai, D.; Lupelli, I.; Marsen, S.; Melson, T. F.; Meszaros, B.; Morgan, P.; Petravich, G.; Refy, D. I.; Silva, C.; Stamp, M.; Szabolics, T.; Zastrow, K.-D.; Zoletnik, S.; JET-EFDA Contributors

    2012-10-01

    A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

  5. Extreme ultraviolet and soft x-ray diagnostics of high-temperature plasmas. Annual progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moos, H W; Armstrong, L Jr

    1980-01-01

    The work performed from mid-January 1979 through 1980 is described. EUV diagnostic studies have been performed at the Alcator A and C Tokamaks, and on TMX. A toroidal asymmetry has been found in the low density phase of Alcator A. The confinement time of impurities has been measured on Alcator A. Impurity concentrations in the center cell of TMX have been studied using EUV spectroscopic techniques. A time resolving spectrograph with 1024 detector elements is essentially complete.

  6. A spatially resolved pyrometer for measuring the blackbody temperature of a warm dense plasma

    DOE PAGES

    Coleman, Joshua Eugene

    2016-12-30

    A pyrometer has been developed to spatially resolve the blackbody temperature of a radiatively cooling warm dense plasma. The pyrometer is composed of a lens coupled fiber array, Czerny-Turner visible spectrometer, and an intensified gated CCD for the detector. The radiatively cooling warm dense plasma is generated by a ~100-ns-long intense relativistic electron bunch with an energy of 19.1 MeV and a current of 0.2 kA interacting with 100-μm-thick low-Z foils. The continuum spectrum is measured over 250 nm with a low groove density grating. These plasmas emit visible light or blackbody radiation on relatively long time scales (~0.1 tomore » 100 μs). Finally, we presented the diagnostic layout, calibration, and proof-of-principle measurement of a radiatively cooling aluminum plasma, which includes a spatially resolved temperature gradient and the ability to temporally resolve it also.« less

  7. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  8. [Stomatological problems related to pregnancy. A statistical study].

    PubMed

    Masoni, S; Panattoni, E; Rolla, P; Rossi, M; Giuca, M R; Gabriele, M

    1991-12-01

    Pregnancy is related to particular dental issues, such as the increased incidence of diseases( gingivitis, caries, epulis), the fluoride supplementation, and the limits of diagnostics and therapy. Moreover, the mysterious halo surrounding pregnancy often makes the dentist uneasy. In order to objectively evaluate the implications of pregnancy in dentistry, we distributed a form to 100 pregnant women. The results of the form showed that 53 of them had gingival bleeding, 22 had toothache, 19 had caries but that just 12 of them had gone to the dentist because of dental troubles while 54 had not gone at all. Among the pluri-gravidae, all the women with dental diseases in their previous pregnancies had them again in their current pregnancy but nonetheless only some had undergone a dental check-up. The dentists did not show any uneasiness, as they performed tooth extractions in 5 women, endodontics in 2 women and fillings in 11 women. Just 4 out of 100 women had taken a fluoride supplementation. We deem advisable a stronger collaboration between physician, gynecologist and dentist in order to resolve specialist problems and to make pregnant women more aware of the need for dental follow-ups and fluoride supplementations.

  9. Scanning system for angle-resolved low-coherence interferometry.

    PubMed

    Steelman, Zachary A; Ho, Derek; Chu, Kengyeh K; Wax, Adam

    2017-11-15

    Angle-resolved low-coherence interferometry (a/LCI) detects precancer by enabling depth-resolved measurements of nuclear morphology in vivo. A significant limitation of a/LCI is the point-probe nature of the method, sampling <0.5  mm 2 before probe relocation is necessary. In this work, we demonstrate a scanning method capable of assessing an area >100  mm 2 without repositioning. By utilizing a reflection-only three-optic rotator prism and a two-axis scanning mirror, we demonstrate radial scans of a sample with a linear range of 12 mm and a full rotational range of 180°. Use of this design will improve the diagnostic utility of a/LCI for wide-area screening of tissue health.

  10. A scanning system for angle-resolved low-coherence interferometry

    PubMed Central

    Steelman, Zachary A.; Ho, Derek; Chu, Kengyeh K.; Wax, Adam

    2018-01-01

    Angle-resolved low-coherence interferometry (a/LCI) detects precancer by enabling depth-resolved measurements of nuclear morphology in vivo. A significant limitation of a/LCI is the point-probe nature of the method, sampling <0.5 mm2 before probe relocation is necessary. In this work, we demonstrate a scanning method capable of assessing an area >100 mm2 without repositioning. By utilizing a reflection-only three-optic rotator (ROTOR) prism and two-axis scanning mirror, we demonstrate radial scans of a sample with a linear range of 12 mm and a full rotational range of 180°. Use of this design will improve the diagnostic utility of a/LCI for wide-area screening of tissue health. PMID:29140317

  11. The Application of LT-Table in TRIZ Contradiction Resolving Process

    NASA Astrophysics Data System (ADS)

    Wei, Zihui; Li, Qinghai; Wang, Donglin; Tian, Yumei

    TRIZ is used to resolve invention problems. ARIZ is the most powerful systematic method which integrates all of TRIZ heuristics. Definition of ideal final result (IFR), identification of contradictions and resource utilization are main lines of ARIZ. But resource searching of ARIZ has fault of blindness. Alexandr sets up mathematical model of transformation of the hereditary information in an invention problem using the theory of catastrophes, and provides method of resource searching using LT-table. The application of LT-table on contradiction resolving is introduced. Resource utilization using LT-table is joined into ARIZ step as an addition of TRIZ, apply this method in separator paper punching machine design.

  12. Fluorescence Lifetime Techniques in Medical Applications

    PubMed Central

    Marcu, Laura

    2012-01-01

    This article presents an overview of time-resolved (lifetime) fluorescence techniques used in biomedical diagnostics. In particular, we review the development of time-resolved fluorescence spectroscopy (TRFS) and fluorescence lifetime imaging (FLIM) instrumentation and associated methodologies which allows for in vivo characterization and diagnosis of biological tissues. Emphasis is placed on the translational research potential of these techniques and on evaluating whether intrinsic fluorescence signals provide useful contrast for the diagnosis of human diseases including cancer (gastrointestinal tract, lung, head and neck, and brain), skin and eye diseases, and atherosclerotic cardiovascular disease. PMID:22273730

  13. Reversible grasp reflexes in normal pressure hydrocephalus.

    PubMed

    Thomas, Rhys H; Bennetto, Luke; Silva, Mark T

    2009-05-01

    We present two cases of normal pressure hydrocephalus in combination with grasp reflexes. In both cases the grasp reflexes disappeared following high volume cerebrospinal fluid removal. In one of the cases the grasp reflexes returned over a period of weeks but again resolved following definitive cerebrospinal fluid shunting surgery, and remained absent until final follow up at 9 months. We hypothesise that resolving grasp reflexes following high volume CSF removal has both diagnostic and prognostic value in normal pressure hydrocephalus, encouraging larger studies on the relevance of primitive reflexes in NPH.

  14. The Far Infrared Lines of OH as Molecular Cloud Diagnostics

    NASA Technical Reports Server (NTRS)

    Smith, Howard A.

    2004-01-01

    Future IR missions should give some priority to high resolution spectroscopic observations of the set of far-IR transitions of OH. There are 15 far-IR lines arising between the lowest eight rotational levels of OH, and ISO detected nine of them. Furthermore, ISO found the OH lines, sometimes in emission and sometimes in absorption, in a wide variety of galactic and extragalactic objects ranging from AGB stars to molecular clouds to active galactic nuclei and ultra-luminous IR galaxies. The ISO/LWS Fabry-Perot resolved the 119 m doublet line in a few of the strong sources. This set of OH lines provides a uniquely important diagnostic for many reasons: the lines span a wide wavelength range (28.9 m to 163.2 m); the transitions have fast radiative rates; the abundance of the species is relatively high; the IR continuum plays an important role as a pump; the contribution from shocks is relatively minor; and, not least, the powerful centimeter-wave radiation from OH allows comparison with radio and VLBI datasets. The problem is that the large number of sensitive free parameters, and the large optical depths of the strongest lines, make modeling the full set a difficult job. The SWAS montecarlo radiative transfer code has been used to analyze the ISO/LWS spectra of a number of objects with good success, including in both the lines and the FIR continuum; the DUSTY radiative transfer code was used to insure a self-consistent continuum. Other far IR lines including those from H2O, CO, and [OI] are also in the code. The OH lines all show features which future FIR spectrometers should be able to resolve, and which will enable further refinements in the details of each cloud's structure. Some examples are given, including the case of S140, for which independent SWAS data found evidence for bulk flows.

  15. Lithium ion beam divergence on SABRE extraction ion diode experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanson, D.L.; Cuneo, M.E.; Johnson, D.J.

    Intense lithium beams are of particular interest for light ion inertial confinement fusion applications because lithium ions can be accelerated at high voltage in a single charge state (Li{sup +}) with a high mass-to-charge ratio and appropriate range for efficient focusing and heating of a hohlraum ICF target. Scaling to ion power densities adequate to drive high gain pellet implosions (600 TW at 30 MeV) will require a large number of beams transported, temporally bunched, and focused onto a target, with the necessary target standoff to ensure survival of the driver modules. For efficient long distance transport and focusing tomore » a small pellet, lithium beam divergence must be reduced to about 12 mrad or less (depending on the transport scheme). To support the eventual development of a light ion driver module for ICF applications, the authors are currently working to improve the composition, uniformity, and divergence of lithium ion beams produced by both passive LiF and active laser-generated lithium ion sources on extraction applied-B ion diodes on the SABRE accelerator (1 TW, 5 MV, 250 kA). While lithium beam divergence accounting and control are an essential goal of these experiments, divergence measurements for lithium beams present some unique problems not encountered to the same degree in divergence measurements on proton sources. To avoid these difficulties, the authors have developed a large aperture ion imaging diagnostic for time-resolved lithium divergence measurements. The authors will report on the operation of this lithium beam divergence diagnostic and on results of time-resolved divergence measurements in progress for passive LiF ion sources and laser-produced active lithium sources operated in diode configurations designed to control divergence growth. Comparisons will also be made with time-integrated divergence results obtained with small entrance aperture ultracompact pinhole cameras.« less

  16. Living without supersymmetry—the conformal alternative and a dynamical Higgs boson

    NASA Astrophysics Data System (ADS)

    Mannheim, Philip D.

    2017-11-01

    We show that the key results of supersymmetry can be achieved via conformal symmetry instead. We propose that the Higgs boson be a dynamical fermion-antifermion bound state rather than an elementary scalar field, so that there is then no quadratically divergent self-energy problem for it and thus no need to invoke supersymmetry to resolve the problem. To obtain such a dynamical Higgs boson we study a conformal invariant gauge theory of interacting fermions and gauge bosons. The conformal invariance of the theory is realized via scaling with anomalous dimensions in the ultraviolet, and by a dynamical symmetry breaking via fermion bilinear condensates in the infrared, a breaking in which the dynamical dimension of the composite operator \\bar{\\psi }\\psi is reduced from three to two. With this reduction in dimension we can augment the gauge theory with a four-fermion interaction made renormalizable by this reduction, and can reinterpret the theory as a renormalizable version of the Nambu-Jona-Lasinio (NJL) model, with the gauge theory sector with its now massive fermion being a mean-field theory and the four-fermion interaction being the residual interaction. It is this residual interaction and not the mean field that then generates dynamical Goldstone and Higgs states, states that, as noted by Baker and Johnson, the gauge theory sector itself does not possess. The Higgs boson is found to be a narrow resonance just above threshold, with its width potentially being a diagnostic that could distinguish a dynamical Higgs boson from an elementary one. We couple the theory to a gravity theory, conformal gravity, that is equally conformal invariant, with the interplay between conformal gravity and the four-fermion interaction taking care of the vacuum energy problem. With conformal gravity being a unitary and renormalizable quantum theory of gravity there is no need for string theory with its supersymmetric underpinnings. With the vacuum energy problem being resolved and with conformal gravity fits to phenomena such as galactic rotation curves and the accelerating universe not needing dark matter, there is no need to introduce supersymmetry for either the vacuum energy problem or to provide a potential dark matter candidate. We propose that it is conformal symmetry rather than supersymmetry that is fundamental, with the theory of nature being a locally conformal, locally gauge invariant, non-Abelian NJL theory.

  17. Do the currently proposed DSM-5 criteria for anorexia nervosa adequately consider developmental aspects in children and adolescents?

    PubMed

    Knoll, Susanne; Bulik, Cynthia M; Hebebrand, Johannes

    2011-02-01

    The purpose of this article is to discuss the proposed criteria of the fifth version of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) for anorexia nervosa (AN) and to compare these with an alternative proposal which is based on a broader conception of the AN phenotype (Hebebrand and Bulik, in press). The proposed DSM-5 criteria seem to only insufficiently resolve the problems inherent to the current classification of AN because (1) the A criterion does not include a reference to allow the clinician to decide if the (young) patient meets the weight criterion, (2) the AN patient first must have evolved the cognitive capacity for complex abstract reasoning in order to fulfill the criteria B and C (Bravender et al. in Eur Eat Disord Rev 18:79-89, 2010), (3) physical symptoms of starvation including the neuroendocrine dysfunction characteristic of AN are not a diagnostic requirement, and (4) the subtypes are not helpful for classification of younger patients who almost all have the restricting type. On these grounds the proposed DSM-5 criteria will perpetuate the diagnostic tradition of a high percentage of patients who are subsumed under the diagnosis of eating disorders not otherwise specified (EDNOS), thus hampering both clinical practice and research. The use of our recently proposed alternative criteria for AN would result in most children and adolescents with an AN-like phenotype receiving a diagnosis of AN. Accordingly, our proposed criteria would be readily applicable to children, adolescents and adults.

  18. A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra.

    PubMed

    Metzkes, J; Karsch, L; Kraft, S D; Pawelke, J; Richter, C; Schürer, M; Sobiella, M; Stiller, N; Zeil, K; Schramm, U

    2012-12-01

    In recent years, a new generation of high repetition rate (~10 Hz), high power (~100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of ~1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

  19. Time for a change: addressing R&D and commercialization challenges for antibacterials

    PubMed Central

    Payne, David J.; Miller, Linda Federici; Findlay, David; Anderson, James; Marks, Lynn

    2015-01-01

    The antibacterial therapeutic area has been described as the perfect storm. Resistance is increasing to the point that our hospitals encounter patients infected with untreatable pathogens, the overall industry pipeline is described as dry and most multinational pharmaceutical companies have withdrawn from the area. Major contributing factors to the declining antibacterial industry pipeline include scientific challenges, clinical/regulatory hurdles and low return on investment. This paper examines these challenges and proposes approaches to address them. There is a need for a broader scientific agenda to explore new approaches to discover and develop antibacterial agents. Additionally, ideas of how industry and academia could be better integrated will be presented. While promising progress in the regulatory environment has been made, more streamlined regulatory paths are still required and the solutions will lie in global harmonization and clearly defined guidance. Creating the right incentives for antibacterial research and development is critical and a new commercial model for antibacterial agents will be proposed. One key solution to help resolve both the problem of antimicrobial resistance (AMR) and lack of new drug development are rapid, cost-effective, accurate point of care diagnostics that will transform antibacterial prescribing and enable more cost-effective and efficient antibacterial clinical trials. The challenges of AMR are too great for any one group to resolve and success will require leadership and partnerships among academia, industry and governments globally. PMID:25918443

  20. Discovery of Low-ionization Envelopes in the Planetary Nebula NGC 5189: Spatially-resolved Diagnostics from HST Observations

    NASA Astrophysics Data System (ADS)

    Danehkar, Ashkbiz; Karovska, Margarita; Maksym, Walter Peter; Montez, Rodolfo

    2018-01-01

    The planetary nebula NGC 5189 shows one of the most spectacular morphological structures among planetary nebulae with [WR]-type central stars. Using high-angular resolution HST/WFC3 imaging, we discovered inner, low-ionization structures within a region of 0.3 parsec × 0.2 parsec around the central binary system. We used Hα, [O III], and [S II] emission line images to construct line-ratio diagnostic maps, which allowed us to spatially resolve two distinct low-ionization envelopes within the inner, ionized gaseous environment, extending over a distance of 0.15 pc from the central binary. Both the low-ionization envelopes appear to be expanding along a NE to SW symmetric axis. The SW envelope appears smaller than its NE counterpart. Our diagnostic maps show that highly-ionized gas surrounds these low-ionization envelopes, which also include filamentary and clumpy structures. These envelopes could be a result of a powerful outburst from the central interacting binary, when one of the companions (now a [WR] star) was in its AGB evolutionary stage, with a strong mass-loss generating dense circumstellar shells. Dense material ejected from the progenitor AGB star is likely heated up as it propagates along a symmetric axis into the previously expelled low-density material. Our new diagnostic methodology is a powerful tool for high-angular resolution mapping of low-ionization structures in other planetary nebulae with complex structures possibly caused by past outbursts from their progenitors.

  1. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T.

    PubMed

    Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares

    2018-02-01

    We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p < 0.0005). Aortic flow showed no difference between ECG- and Doppler-triggered and MOG (p > 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.

  2. Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Imrisek, M.; Faculty of Mathematics and Physics, Charles University in Prague, Prague; Weinzettl, V.

    2014-11-15

    The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.

  3. Calibration techniques for a fast duo-spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, J.T.; Den Hartog, D.J.

    1996-06-01

    The authors have completed the upgrade and calibration of the Ion Dynamics Spectrometer (IDS), a high-speed Doppler duo-spectrometer which measures ion flow and temperature in the MST Reversed-field Pinch. This paper describes an in situ calibration of the diagnostic`s phase and frequency response. A single clock was employed to generate both a digital test signal and a digitizer trigger thus avoiding frequency drift and providing a highly resolved measurement over the system bandwidth. Additionally, they review the measurement of the spectrometer instrument function and absolute intensity response. This calibration and subsequent performance demonstrate the IDS to be one of themore » fastest, highest throughput diagnostics of its kind. Typical measurements are presented.« less

  4. The Difference between Uncertainty and Information, and Why This Matters

    NASA Astrophysics Data System (ADS)

    Nearing, G. S.

    2016-12-01

    Earth science investigation and arbitration (for decision making) is very often organized around a concept of uncertainty. It seems relatively straightforward that the purpose of our science is to reduce uncertainty about how environmental systems will react and evolve under different conditions. I propose here that approaching a science of complex systems as a process of quantifying and reducing uncertainty is a mistake, and specifically a mistake that is rooted in certain rather hisoric logical errors. Instead I propose that we should be asking questions about information. I argue here that an information-based perspective facilitates almost trivial answers to environmental science questions that are either difficult or theoretically impossible to answer when posed as questions about uncertainty. In particular, I propose that an information-centric perspective leads to: Coherent and non-subjective hypothesis tests for complex system models. Process-level diagnostics for complex systems models. Methods for building complex systems models that allow for inductive inference without the need for a priori specification of likelihood functions or ad hoc error metrics. Asymptotically correct quantification of epistemic uncertainty. To put this in slightly more basic terms, I propose that an information-theoretic philosophy of science has the potential to resolve certain important aspects of the Demarcation Problem and the Duhem-Quine Problem, and that Hydrology and other Earth Systems Sciences can immediately capitalize on this to address some of our most difficult and persistent problems.

  5. Investigating the role of future thinking in social problem solving.

    PubMed

    Noreen, Saima; Whyte, Katherine E; Dritschel, Barbara

    2015-03-01

    There is well-established evidence that both rumination and depressed mood negatively impact the ability to solve social problems. A preliminary stage of the social problem solving process may be the process of catapulting oneself forward in time to think about the consequences of a problem before attempting to solve it. The aim of the present study was to examine how thinking about the consequences of a social problem being resolved or unresolved prior to solving it influences the solution of the problem as a function of levels of rumination and dysphoric mood. Eighty six participants initially completed the Beck Depression Inventory- II (BDI-II) and the Ruminative Response Scale (RRS). They were then presented with six social problems and generated consequences for half of the problems being resolved and half of the problems remaining unresolved. Participants then solved some of the problems, and following a delay, were asked to recall all of the consequences previously generated. Participants reporting higher levels of depressed mood and rumination were less effective at generating problem solutions. Specifically, those reporting higher levels of rumination produced less effective solutions for social problems that they had previously generated unresolved than resolved consequences. We also found that individuals higher in rumination, irrespective of depressed mood recalled more of the unresolved consequences in a subsequent memory test. As participants did not solve problems for scenarios where no consequences were generated, no baseline measure of problem solving was obtained. Our results suggest thinking about the consequences of a problem remaining unresolved may impair the generation of effective solutions in individuals with higher levels of rumination. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Feeding and Eating Disorders: Ingestive Problems of Infancy, Childhood, and Adolescence.

    ERIC Educational Resources Information Center

    Kerwin, MaryLouise E.; Berkowitz, Robert I.

    1996-01-01

    The fourth edition of the "Diagnostic Statistical Manual of Mental Disorders" (DSM) recognizes that feeding problems of infants and children are not typically the same as eating problems of adolescents, thus the addition of a broad diagnostic category, "Feeding and Eating Disorders of Infancy or Early Childhood." Subtypes are…

  7. The Width Distribution of Loops and Strands in the Solar Corona—Are We Hitting Rock Bottom?

    NASA Astrophysics Data System (ADS)

    Aschwanden, Markus J.; Peter, Hardi

    2017-05-01

    In this study, we analyze Atmospheric Imaging Assembly (AIA) and Hi-C images in order to investigate absolute limits for the finest loop strands. We develop a model of the occurrence-size distribution function of coronal loop widths, characterized by the lower limit of widths w min, the peak (or most frequent) width w p , the peak occurrence number n p , and a power-law slope a. Our data analysis includes automated tracing of curvilinear features with the OCCULT-2 code, automated sampling of the cross-sectional widths of coronal loops, and fitting of the theoretical size distribution to the observed distribution. With Monte Carlo simulations and variable pixel sizes {{Δ }}x, we derive a first diagnostic criterion to discriminate whether the loop widths are unresolved ({w}p/{{Δ }}x≈ 2.5+/- 0.2) or fully resolved (if {w}p/{{Δ }}x≳ 2.7). For images with resolved loop widths, we can apply a second diagnostic criterion that predicts the lower limit of loop widths as a function of the spatial resolution. We find that the loop widths are marginally resolved in AIA images but are fully resolved in Hi-C images, where our model predicts a most frequent (peak) value at {w}p≈ 550 {km}, in agreement with recent results of Brooks et al. This result agrees with the statistics of photospheric granulation sizes and thus supports coronal heating mechanisms operating on the macroscopic scale of photospheric magneto-convection, rather than nanoflare braiding models on unresolved microscopic scales.

  8. Spatially resolved heat release rate measurements in turbulent premixed flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayoola, B.O.; Kaminski, C.F.; Balachandran, R.

    Heat release rate is a fundamental property of great importance for the theoretical and experimental elucidation of unsteady flame behaviors such as combustion noise, combustion instabilities, and pulsed combustion. Investigations of such thermoacoustic interactions require a reliable indicator of heat release rate capable of resolving spatial structures in turbulent flames. Traditionally, heat release rate has been estimated via OH or CH radical chemiluminescence; however, chemiluminescence suffers from being a line-of-sight technique with limited capability for resolving small-scale structures. In this paper, we report spatially resolved two-dimensional measurements of a quantity closely related to heat release rate. The diagnostic technique usesmore » simultaneous OH and CH{sub 2}O planar laser-induced fluorescence (PLIF), and the pixel-by-pixel product of the OH and CH{sub 2}O PLIF signals has previously been shown to correlate well with local heat release rates. Results from this diagnostic technique, which we refer to as heat release rate imaging (HR imaging), are compared with traditional OH chemiluminescence measurements in several flames. Studies were performed in lean premixed ethylene flames stabilized between opposed jets and with a bluff body. Correlations between bulk strain rates and local heat release rates were obtained and the effects of curvature on heat release rate were investigated. The results show that the heat release rate tends to increase with increasing negative curvature for the flames investigated for which Lewis numbers are greater than unity. This correlation becomes more pronounced as the flame gets closer to global extinction.« less

  9. Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps

    NASA Astrophysics Data System (ADS)

    Hell, N.; Beiersdorfer, P.; Magee, E. W.; Brown, G. V.

    2016-11-01

    We report the calibration of the Orion High-Resolution X-ray (OHREX) imaging crystal spectrometer at the EBIT-I electron beam ion trap at Livermore. Two such instruments, dubbed OHREX-1 and OHREX-2, are fielded for plasma diagnostics at the Orion laser facility in the United Kingdom. The OHREX spectrometer can simultaneously house two spherically bent crystals with a radius of curvature of r = 67.2 cm. The focusing properties of the spectrometer allow both for larger distance to the source due to the increase in collected light and for observation of extended sources. OHREX is designed to cover a 2.5°-3° spectral range at Bragg angles around 51.3°. The typically high resolving powers at these large Bragg angles are ideally suited for line shape diagnostics. For instance, the nominal resolving power of the instrument (>10 000) is much higher than the effective resolving power associated with the Doppler broadening due to the temperature of the trapped ions in EBIT-I. The effective resolving power is only around 3000 at typical EBIT-I conditions, which nevertheless is sufficient to set up and test the instrument's spectral characteristics. We have calibrated the spectral range for a number of crystals using well known reference lines in the first and second order and derived the ion temperatures from these lines. We have also made use of the 50 μm size of the EBIT-I source width to characterize the spatial focusing of the spectrometer.

  10. Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography

    PubMed Central

    Yousaf, Ufra; Hsiao, Albert; Cheng, Joseph Y.; Alley, Marcus T.; Lustig, Michael; Pauly, John M.; Vasanawala, Shreyas S.

    2015-01-01

    Background Pediatric contrast-enhanced MR angiography is often limited by respiration, other patient motion and compromised spatiotemporal resolution. Objective To determine the reliability of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast enhanced MR angiography method for depicting abdominal arterial anatomy in young children. Materials and methods With IRB approval and informed consent, we retrospectively identified 27 consecutive children (16 males and 11 females; mean age: 3.8 years, range: 14 days to 8.4 years) referred for contrast enhanced MR angiography at our institution, who had undergone free-breathing spatiotemporally accelerated time-resolved contrast enhanced MR angiography studies. An radio-frequency-spoiled gradient echo sequence with Cartesian variable density k-space sampling and radial view ordering, intrinsic motion navigation and intermittent fat suppression was developed. Images were reconstructed with soft-gated parallel imaging locally low-rank method to achieve both motion correction and high spatiotemporal resolution. Quality of delineation of 13 abdominal arteries in the reconstructed images was assessed independently by two radiologists on a five-point scale. Ninety-five percent confidence intervals of the proportion of diagnostically adequate cases were calculated. Interobserver agreements were also analyzed. Results Eleven out of 13 arteries achieved acceptable image quality (mean score range: 3.9–5.0) for both readers. Fair to substantial interobserver agreement was reached on nine arteries. Conclusion Free-breathing spatiotemporally accelerated 3-D time-resolved contrast enhanced MR angiography frequently yields diagnostic image quality for most abdominal arteries for pediatric contrast enhanced MR angiography. PMID:26040509

  11. Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hell, N.; Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, Bamberg 96049; Beiersdorfer, P.

    2016-11-15

    We report the calibration of the Orion High-Resolution X-ray (OHREX) imaging crystal spectrometer at the EBIT-I electron beam ion trap at Livermore. Two such instruments, dubbed OHREX-1 and OHREX-2, are fielded for plasma diagnostics at the Orion laser facility in the United Kingdom. The OHREX spectrometer can simultaneously house two spherically bent crystals with a radius of curvature of r = 67.2 cm. The focusing properties of the spectrometer allow both for larger distance to the source due to the increase in collected light and for observation of extended sources. OHREX is designed to cover a 2.5°–3° spectral range atmore » Bragg angles around 51.3°. The typically high resolving powers at these large Bragg angles are ideally suited for line shape diagnostics. For instance, the nominal resolving power of the instrument (>10 000) is much higher than the effective resolving power associated with the Doppler broadening due to the temperature of the trapped ions in EBIT-I. The effective resolving power is only around 3000 at typical EBIT-I conditions, which nevertheless is sufficient to set up and test the instrument’s spectral characteristics. We have calibrated the spectral range for a number of crystals using well known reference lines in the first and second order and derived the ion temperatures from these lines. We have also made use of the 50 μm size of the EBIT-I source width to characterize the spatial focusing of the spectrometer.« less

  12. A robust model predictive control algorithm for uncertain nonlinear systems that guarantees resolvability

    NASA Technical Reports Server (NTRS)

    Acikmese, Ahmet Behcet; Carson, John M., III

    2006-01-01

    A robustly stabilizing MPC (model predictive control) algorithm for uncertain nonlinear systems is developed that guarantees resolvability. With resolvability, initial feasibility of the finite-horizon optimal control problem implies future feasibility in a receding-horizon framework. The control consists of two components; (i) feed-forward, and (ii) feedback part. Feed-forward control is obtained by online solution of a finite-horizon optimal control problem for the nominal system dynamics. The feedback control policy is designed off-line based on a bound on the uncertainty in the system model. The entire controller is shown to be robustly stabilizing with a region of attraction composed of initial states for which the finite-horizon optimal control problem is feasible. The controller design for this algorithm is demonstrated on a class of systems with uncertain nonlinear terms that have norm-bounded derivatives and derivatives in polytopes. An illustrative numerical example is also provided.

  13. Approximation algorithms for a genetic diagnostics problem.

    PubMed

    Kosaraju, S R; Schäffer, A A; Biesecker, L G

    1998-01-01

    We define and study a combinatorial problem called WEIGHTED DIAGNOSTIC COVER (WDC) that models the use of a laboratory technique called genotyping in the diagnosis of an important class of chromosomal aberrations. An optimal solution to WDC would enable us to define a genetic assay that maximizes the diagnostic power for a specified cost of laboratory work. We develop approximation algorithms for WDC by making use of the well-known problem SET COVER for which the greedy heuristic has been extensively studied. We prove worst-case performance bounds on the greedy heuristic for WDC and for another heuristic we call directional greedy. We implemented both heuristics. We also implemented a local search heuristic that takes the solutions obtained by greedy and dir-greedy and applies swaps until they are locally optimal. We report their performance on a real data set that is representative of the options that a clinical geneticist faces for the real diagnostic problem. Many open problems related to WDC remain, both of theoretical interest and practical importance.

  14. Neurosurgery contact handheld probe based on sapphire shaped crystal

    NASA Astrophysics Data System (ADS)

    Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.

    2017-01-01

    A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.

  15. Let's Resolve Conflicts Together: Middle School Classroom Activities. Conflict Management Week, May 1-7, 2000.

    ERIC Educational Resources Information Center

    Ohio Commission on Dispute Resolution and Conflict Management, Columbus.

    Conflict is a natural and inevitable part of living, but managing conflict is difficult for many people because they have not been taught how to resolve differences in cooperative, nonviolent ways. Communication problems can lead to misunderstanding and make conflicts more difficult to resolve. The Governor of Ohio has designated May 1-7, 2000 as…

  16. Understanding healthcare professionals' self-efficacy to resolve interprofessional conflict.

    PubMed

    Sexton, Martha; Orchard, Carole

    2016-05-01

    Conflict within interprofessional healthcare teams, when not effectively resolved, has been linked to detrimental consequences; however, effective conflict resolution has been shown to enhance team performance, increase patient safety, and improve patient outcomes. Alarmingly, knowledge of healthcare professionals' ability to resolve conflict has been limited, largely due to the challenges that arise when researchers attempt to observe a conflict occurring in real time. Research literature has identified three central components that seem to influence healthcare professional's perceived ability to resolve conflict: communication competence, problem-solving ability, and conflict resolution education and training. The purpose of this study was to investigate the impact of communication competence, problem-solving ability, and conflict resolution education and training on healthcare professionals' perceived ability to resolve conflicts. This study employed a cross-sectional survey design. Multiple regression analyses demonstrated that two of the three central components-conflict resolution education and training and communication competence-were found to be statistically significant predictors of healthcare professionals' perceived ability to resolve conflict. Implications include a call to action for clinicians and academicians to recognize the importance of communication competence and conflict resolution education and training as a vital area in interprofessional pre- and post-licensure education and collaborative practice.

  17. Lidars for smoke and dust cloud diagnostics

    NASA Astrophysics Data System (ADS)

    Fujimura, S. F.; Warren, R. E.; Lutomirski, R. F.

    1980-11-01

    An algorithm that integrates a time-resolved lidar signature for use in estimating transmittance, extinction coefficient, mass concentration, and CL values generated under battlefield conditions is applied to lidar signatures measured during the DIRT-I tests. Estimates are given for the dependence of the inferred transmittance and extinction coefficient on uncertainties in parameters such as the obscurant backscatter-to-extinction ratio. The enhanced reliability in estimating transmittance through use of a target behind the obscurant cloud is discussed. It is found that the inversion algorithm can produce reliable estimates of smoke or dust transmittance and extinction from all points within the cloud for which a resolvable signal can be detected, and that a single point calibration measurement can convert the extinction values to mass concentration for each resolvable signal point.

  18. Painful Shoulder in Swimmers: A Diagnostic Challenge.

    ERIC Educational Resources Information Center

    McMaster, William C.

    1986-01-01

    This article discusses the incidence, diagnosis, and treatment of painful shoulder in swimmers, including: regional problems that can cause shoulder pain; physical, clinical, and laboratory tests for diagnostic use; and approaches to management of the problem. (Author/CB)

  19. GENE-07. MOLECULAR NEUROPATHOLOGY 2.0 - INCREASING DIAGNOSTIC ACCURACY IN PEDIATRIC NEUROONCOLOGY

    PubMed Central

    Sturm, Dominik; Jones, David T.W.; Capper, David; Sahm, Felix; von Deimling, Andreas; Rutkoswki, Stefan; Warmuth-Metz, Monika; Bison, Brigitte; Gessi, Marco; Pietsch, Torsten; Pfister, Stefan M.

    2017-01-01

    Abstract The classification of central nervous system (CNS) tumors into clinically and biologically distinct entities and subgroups is challenging. Children and adolescents can be affected by >100 histological variants with very variable outcomes, some of which are exceedingly rare. The current WHO classification has introduced a number of novel molecular markers to aid routine neuropathological diagnostics, and DNA methylation profiling is emerging as a powerful tool to distinguish CNS tumor classes. The Molecular Neuropathology 2.0 study aims to integrate genome wide (epi-)genetic diagnostics with reference neuropathological assessment for all newly-diagnosed pediatric brain tumors in Germany. To date, >350 patients have been enrolled. A molecular diagnosis is established by epigenetic tumor classification through DNA methylation profiling and targeted panel sequencing of >130 genes to detect diagnostically and/or therapeutically useful DNA mutations, structural alterations, and fusion events. Results are aligned with the reference neuropathological diagnosis, and discrepant findings are discussed in a multi-disciplinary tumor board including reference neuroradiological evaluation. Ten FFPE sections as input material are sufficient to establish a molecular diagnosis in >95% of tumors. Alignment with reference pathology results in four broad categories: a) concordant classification (~77%), b) discrepant classification resolvable by tumor board discussion and/or additional data (~5%), c) discrepant classification without currently available options to resolve (~8%), and d) cases currently unclassifiable by molecular diagnostics (~10%). Discrepancies are enriched in certain histopathological entities, such as histological high grade gliomas with a molecularly low grade profile. Gene panel sequencing reveals predisposing germline events in ~10% of patients. Genome wide (epi-)genetic analyses add a valuable layer of information to routine neuropathological diagnostics. Our study provides insight into CNS tumors with divergent histopathological and molecular classification, opening new avenues for research discoveries and facilitating optimization of clinical management for affected patients in the future.

  20. Patient Navigation and Time to Diagnostic Resolution: Results for a Cluster Randomized Trial Evaluating the Efficacy of Patient Navigation among Patients with Breast Cancer Screening Abnormalities, Tampa, FL

    PubMed Central

    Lee, Ji-Hyun; Fulp, William; Wells, Kristen J.; Meade, Cathy D.; Calcano, Ercilia; Roetzheim, Richard

    2013-01-01

    Objectives The objective of this study was to evaluate a patient navigation (PN) program that attempts to reduce the time between a breast cancer screening abnormality and definitive diagnosis among medically underserved populations of Tampa Bay, Florida. Methods The Moffitt Patient Navigation Research Program conducted a cluster randomized design with 10 primary care clinics. Patients were navigated from time of a breast screening abnormality to diagnostic resolution. This paper examined the length of time between breast abnormality and definitive diagnosis, using a shared frailty Cox proportional hazard model to assess PN program effect. Results 1,039 patients were eligible for the study because of an abnormal breast cancer screening/clinical abnormality (494 navigated; 545 control). Analysis of PN effect by two time periods of resolution (0-3 months and > 3 months) showed a lagged effect of PN. For patients resolving in the first three months, the adjusted Hazard Ratio (aHR) was 0.85 (95% Confidence Interval [CI]: 0.64-1.13) suggesting that PN had no effect on resolution time during this period. Beyond three months, however, navigated patients resolved more quickly to diagnostic resolution compared with the control group (aHR 2.8, 95%CI: 1.30-6.13). The predicted aHR at 3 months was 1.2, which was not statistically significant, while PN had a significant positive effect beyond 4.7 months. Conclusions PN programs may increase the timeliness of diagnostic resolution for patients with a breast cancer-related abnormality. PN did not speed diagnostic resolution during the initial three months of follow up but started to reduce time to diagnostic resolution after three months and showed a significant effect after 4.7 months. Trial Registration ClinicalTrials.gov NCT00375024 PMID:24066145

  1. Dante Soft X-ray Power Diagnostic for NIF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewald, E; Campbell, K; Turner, R

    2004-04-15

    Soft x-ray power diagnostics are essential for measuring spectrally resolved the total x-ray flux, radiation temperature, conversion efficiency and albedo that are important quantities for the energetics of indirect drive hohlraums. At the Nova or Omega Laser Facilities, these measurements are performed mainly with Dante, but also with DMX and photo-conductive detectors (PCD's). The Dante broadband spectrometer is a collection of absolute calibrated vacuum x-ray diodes, thin filters and x-ray mirrors used to measure the soft x-ray emission for photon energies above 50 eV.

  2. Design of T-GEM detectors for X-ray diagnostics on JET

    NASA Astrophysics Data System (ADS)

    Rzadkiewicz, J.; Dominik, W.; Scholz, M.; Chernyshova, M.; Czarski, T.; Czyrkowski, H.; Dabrowski, R.; Jakubowska, K.; Karpinski, L.; Kasprowicz, G.; Kierzkowski, K.; Pozniak, K.; Salapa, Z.; Zabolotny, W.; Blanchard, P.; Tyrrell, S.; Zastrow, K.-D.; JET EFDA Contributors

    2013-08-01

    Upgraded high-resolution X-ray diagnostics on JET is expected to monitor the plasma radiation emitted by W46+ and Ni26+ ions at 2.4 keV and 7.8 keV photon energies, respectively. Both X-ray lines will be monitored by new generation energy-resolved micropattern gas detectors with 1-D position reconstruction capability. The detection structure is based on triple GEM (T-GEM) amplification structure followed by the strip readout electrode. This article presents a design of new detectors and prototype detector tests.

  3. Optical diagnostics of the arc plasma using fast intensified CCD-spectrograph system

    NASA Astrophysics Data System (ADS)

    Pavelescu, Gabriela; Guillot, Stephane; Braic, Mariana T.; Hong, Dunpin; Pavelescu, D.; Fleurier, Claude; Braic, Viorel; Gherendi, F.; Dumitrescu, G.; Anghelita, P.; Bauchire, J. M.

    2004-10-01

    Spectroscopic diagnostics, using intensified high speed CCD camera, was applied to study the arc dynamics in low voltage circuit breakers, in vacuum and in air. Time-resolved emission spectroscopy of the vacuum arc plasma, generated during electrode separation, provided information about the interruption process. The investigations were focused on the partial unsuccessful interruption around current zero. Absorption spectroscopy, in a peculiar setup, was used in order to determine the metallic atoms densities in the interelectrode space of a low voltage circuit breaker, working in ambient air.

  4. 34 CFR 395.36 - Enforcement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROPERTY Federal Property Management § 395.36 Enforcement procedures. (a) The State licensing agency shall attempt to resolve day-to-day problems pertaining to the operation of the vending facility in an informal... instrumentality in an attempt to resolve the issue. ...

  5. Evolutions of Advanced Stamping CAE — Technology Adventures and Business Impact on Automotive Dies and Stamping

    NASA Astrophysics Data System (ADS)

    Wang, Chuantao (C. T.)

    2005-08-01

    In the past decade, sheet metal forming and die development has been transformed to a science-based and technology-driven engineering and manufacturing enterprise from a tryout-based craft. Stamping CAE, especially the sheet metal forming simulation, as one of the core components in digital die making and digital stamping, has played a key role in this historical transition. The stamping simulation technology and its industrial applications have greatly impacted automotive sheet metal product design, die developments, die construction and tryout, and production stamping. The stamping CAE community has successfully resolved the traditional formability problems such as splits and wrinkles. The evolution of the stamping CAE technology and business demands opens even greater opportunities and challenges to stamping CAE community in the areas of (1) continuously improving simulation accuracy, drastically reducing simulation time-in-system, and improving operationalability (friendliness), (2) resolving those historically difficult-to-resolve problems such as dimensional quality problems (springback and twist) and surface quality problems (distortion and skid/impact lines), (3) resolving total manufacturability problems in line die operations including blanking, draw/redraw, trim/piercing, and flanging, and (4) overcoming new problems in forming new sheet materials with new forming techniques. In this article, the author first provides an overview of the stamping CAE technology adventures and achievements, and industrial applications in the past decade. Then the author presents a summary of increasing manufacturability needs from the formability to total quality and total manufacturability of sheet metal stampings. Finally, the paper outlines the new needs and trends for continuous improvements and innovations to meet increasing challenges in line die formability and quality requirements in automotive stamping.

  6. Fast reconstruction of optical properties for complex segmentations in near infrared imaging

    NASA Astrophysics Data System (ADS)

    Jiang, Jingjing; Wolf, Martin; Sánchez Majos, Salvador

    2017-04-01

    The intrinsic ill-posed nature of the inverse problem in near infrared imaging makes the reconstruction of fine details of objects deeply embedded in turbid media challenging even for the large amounts of data provided by time-resolved cameras. In addition, most reconstruction algorithms for this type of measurements are only suitable for highly symmetric geometries and rely on a linear approximation to the diffusion equation since a numerical solution of the fully non-linear problem is computationally too expensive. In this paper, we will show that a problem of practical interest can be successfully addressed making efficient use of the totality of the information supplied by time-resolved cameras. We set aside the goal of achieving high spatial resolution for deep structures and focus on the reconstruction of complex arrangements of large regions. We show numerical results based on a combined approach of wavelength-normalized data and prior geometrical information, defining a fully parallelizable problem in arbitrary geometries for time-resolved measurements. Fast reconstructions are obtained using a diffusion approximation and Monte-Carlo simulations, parallelized in a multicore computer and a GPU respectively.

  7. Spatially resolved density and ionization measurements of shocked foams using x-ray fluorescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDonald, M. J.; Keiter, P. A.; Montgomery, D. S.

    2016-09-28

    We present experiments at the Trident laser facility demonstrating the use of x-ray fluorescence (XRF) to simultaneously measure density, ionization state populations, and electron temperature in shocked foams. An imaging x-ray spectrometer obtained spatially resolved measurements of Ti K-α emission. Density profiles were measured from K-α intensity. Ti ionization state distributions and electron temperatures were inferred by fitting K-α spectra to spectra from CRETIN simulations. This work shows that XRF provides a powerful tool to complement other diagnostics to make equation of state measurements of shocked materials containing a suitable tracer element.

  8. Detection of melanomas by digital imaging of spectrally resolved UV light-induced autofluorescence of human skin

    NASA Astrophysics Data System (ADS)

    Chwirot, B. W.; Chwirot, S.; Jedrzejczyk, W.; Redzinski, J.; Raczynska, A. M.; Telega, K.

    2001-07-01

    We studied spectral and spatial distributions of the intensity of the ultraviolet light-excited fluorescence of human skin. Our studied performed in situ in 162 patients with malignant and non-malignant skin lesions resulted in a new method of detecting melanomas in situ using digital imaging of the spectrally resolved fluorescence. With our diagnostic algorithm we could successfully detect 88.5% of the cases of melanoma in the group of patients subject to examinations with the fluorescence method. A patent application for the method has been submitted to the Patent Office in Warsaw.

  9. Rise time measurement for ultrafast X-ray pulses

    DOEpatents

    Celliers, Peter M [Berkeley, CA; Weber, Franz A [Oakland, CA; Moon, Stephen J [Tracy, CA

    2005-04-05

    A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

  10. Rise Time Measurement for Ultrafast X-Ray Pulses

    DOEpatents

    Celliers, Peter M.; Weber, Franz A.; Moon, Stephen J.

    2005-04-05

    A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

  11. Development of an intelligent diagnostic system for reusable rocket engine control

    NASA Technical Reports Server (NTRS)

    Anex, R. P.; Russell, J. R.; Guo, T.-H.

    1991-01-01

    A description of an intelligent diagnostic system for the Space Shuttle Main Engines (SSME) is presented. This system is suitable for incorporation in an intelligent controller which implements accommodating closed-loop control to extend engine life and maximize available performance. The diagnostic system architecture is a modular, hierarchical, blackboard system which is particularly well suited for real-time implementation of a system which must be repeatedly updated and extended. The diagnostic problem is formulated as a hierarchical classification problem in which the failure hypotheses are represented in terms of predefined data patterns. The diagnostic expert system incorporates techniques for priority-based diagnostics, the combination of analytical and heuristic knowledge for diagnosis, integration of different AI systems, and the implementation of hierarchical distributed systems. A prototype reusable rocket engine diagnostic system (ReREDS) has been implemented. The prototype user interface and diagnostic performance using SSME test data are described.

  12. Epidural Hematoma Complication after Rapid Chronic Subdural Hematoma Evacuation: A Case Report

    PubMed Central

    Akpinar, Aykut; Ucler, Necati; Erdogan, Uzay; Yucetas, Cem Seyho

    2015-01-01

    Patient: Male, 41 Final Diagnosis: Healty Symptoms: Headache Medication: — Clinical Procedure: Chronic subdural hematoma Specialty: Neurosurgery Objective: Diagnostic/therapeutic accidents Background: Chronic subdural hematoma generally occurs in the elderly. After chronic subdural hematoma evacuation surgery, the development of epidural hematoma is a very rare entity. Case Report: We report the case of a 41-year-old man with an epidural hematoma complication after chronic subdural hematoma evacuation. Under general anesthesia, the patient underwent a large craniotomy with closed system drainage performed to treat the chronic subdural hematoma. After chronic subdural hematoma evacuation, there was epidural leakage on the following day. Conclusions: Although trauma is the most common risk factor in young CSDH patients, some other predisposing factors may exist. Intracranial hypotension can cause EDH. Craniotomy and drainage surgery can usually resolve the problem. Because of rapid dynamic intracranial changes, epidural leakages can occur. A large craniotomy flap and silicone drainage in the operation area are key safety points for neurosurgeons and hydration is essential. PMID:26147957

  13. Predicate calculus, artificial intelligence, and workers' compensation.

    PubMed

    Harber, P; McCoy, J M

    1989-05-01

    Application of principles of predicate calculus (PC) and artificial intelligence (AI) search methods to occupational medicine can meet several goals. First, they can improve understanding of the diagnostic process and recognition of the sources of uncertainty in knowledge and in case specific information. Second, PC provides a rational means of resolving differences in conclusion based upon the same premises. Third, understanding of these principles allows separation of knowledge (facts) from the process by which they are used and therefore facilitates development of AI-based expert systems. Application of PC to recognizing causation of pulmonary fibrosis is demonstrated in this paper, providing a method that can be generalized to other problems in occupational medicine. Application of PC and understanding of AI search routines may be particularly applicable to workers' compensation where explicit statement of rational and inferential process is necessary. This approach is useful in the diagnosis of occupational lung disease and may be particularly valuable in workers' compensation considerations, wherein explicit statement of rationale is needed.

  14. Henrietta Lacks, HeLa cells, and cell culture contamination.

    PubMed

    Lucey, Brendan P; Nelson-Rees, Walter A; Hutchins, Grover M

    2009-09-01

    Henrietta Lacks died in 1951 of an aggressive adenocarcinoma of the cervix. A tissue biopsy obtained for diagnostic evaluation yielded additional tissue for Dr George O. Gey's tissue culture laboratory at Johns Hopkins (Baltimore, Maryland). The cancer cells, now called HeLa cells, grew rapidly in cell culture and became the first human cell line. HeLa cells were used by researchers around the world. However, 20 years after Henrietta Lacks' death, mounting evidence suggested that HeLa cells contaminated and overgrew other cell lines. Cultures, supposedly of tissues such as breast cancer or mouse, proved to be HeLa cells. We describe the history behind the development of HeLa cells, including the first published description of Ms Lacks' autopsy, and the cell culture contamination that resulted. The debate over cell culture contamination began in the 1970s and was not harmonious. Ultimately, the problem was not resolved and it continues today. Finally, we discuss the philosophical implications of the immortal HeLa cell line.

  15. [Obesity and metabolic syndrome in adolescents].

    PubMed

    Cárdenas Villarreal, Velia Margarita; Rizo-Baeza, María M; Cortés Castell, Ernesto

    2009-03-01

    In spite of the lack of a uniform definition for metabolic syndrome in pediatry, recent studies have shown that it develops during childhood and is highly prevalent among children and adolescents who suffer from obesity. In light of the current epidemic of obesity in this age category in western countries, and specifically in Mexico, it becomes essential to know the means to prevent, detect and treat this syndrome. Nurses play an important role in promoting childhood health with regards to metabolic syndrome. To put into practice the strategies which resolve underlying problems related with this syndrome is a priority for the well-being of this age group. These strategies should include the application and management of public policies; the collaboration by health services, social services and schools; but, furthermore, the prevention and the management of this syndrome require a family commitment, while the changes in living habits benefit the entire family. This review article proposes to introduce prevention, diagnostic and treatment strategies which nursing personnel can carry out while dealing with metabolic syndrome in adolescents.

  16. Recombinant proteins and peptides as diagnostic and therapeutic reagents for arthropod allergies.

    PubMed

    Ramos, John Donnie A; Valmonte, Gardette R; de Guia, Roldan M

    2007-01-01

    Domestic arthropods are chief sources of potent allergens that trigger sensitization and stimulate IgE-mediated allergies. Diagnosis and immunotherapy of arthropod allergies rely on the use of natural allergen extracts which are associated with low specificity and efficacy, the risk of anaphylactic reactions, and the extended period of treatment. Most of the problems associated with natural allergen extracts for allergy diagnosis and immunotherapy can be circumvented with the use of recombinant allergens and peptides. Recombinant allergens are recently developed for microarray-based multi-allergen tests which provide component-resolved diagnosis (CRD) of the patient's sensitization profile. Moreover, recombinant protein technology and peptide chemistry have been used to construct isoallergens, allergen mutants, allergoids, T and B cell peptides, hypoallergens, and mimotopes with reduced allergenicity but enhanced immunogenicity for allergen-specific immunotherapy (SIT) and vaccination. The basics of recombinant arthropod allergen technology are in place providing a lucid future for the advancement of diagnosis and immunotherapy of arthropod allergies.

  17. Insertion of an SVA element, a nonautonomous retrotransposon, in PMS2 intron 7 as a novel cause of Lynch syndrome.

    PubMed

    van der Klift, Heleen M; Tops, Carli M; Hes, Frederik J; Devilee, Peter; Wijnen, Juul T

    2012-07-01

    Heterozygous germline mutations in the mismatch repair gene PMS2 predispose carriers for Lynch syndrome, an autosomal dominant predisposition to cancer. Here, we present a LINE-1-mediated retrotranspositional insertion in PMS2 as a novel mutation type for Lynch syndrome. This insertion, detected with Southern blot analysis in the genomic DNA of the patient, is characterized as a 2.2 kb long 5' truncated SVA_F element. The insertion is not detectable by current diagnostic testing limited to MLPA and direct Sanger sequencing on genomic DNA. The molecular nature of this insertion could only be resolved in RNA from cultured lymphocytes in which nonsense-mediated RNA decay was inhibited. Our report illustrates the technical problems encountered in the detection of this mutation type. Especially large heterozygous insertions will remain unnoticed because of preferential amplification of the smaller wild-type allele in genomic DNA, and are probably underreported in the mutation spectra of autosomal dominant disorders. © 2012 Wiley Periodicals, Inc.

  18. Laser diagnostics for combustion temperature and species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckbreth, A.C.

    1987-01-01

    Laser approaches to combustion diagnostics are of considerable interest due to their remote, nonintrusive and in-situ character, unlimited temperature capability and potential for simultaneous temporal and spatial resolution, This book aims to make these powerful and important new tools in combustion research understandable. The focus of this text is on spectroscopically-based, spatially-precise laser techniques for temperature and chemical composition measurements in reacting and nonreacting flows. After introductory chapters providing a fundamental theoretical and experimental background, attention is directed to diagnostics based upon spontaneous Raman and Rayleigh scattering, coherent anti-Stokes Raman spectroscopy (CARS) and laser-induced fluorescence (LIFS). The book concludes withmore » a treatment of techniques which permit spatially-resolved measurements over an entire two-dimensional field simultaneously.« less

  19. Quantitative Thermochemical Measurements in High-Pressure Gaseous Combustion

    NASA Technical Reports Server (NTRS)

    Kojima, Jun J.; Fischer, David G.

    2012-01-01

    We present our strategic experiment and thermochemical analyses on combustion flow using a subframe burst gating (SBG) Raman spectroscopy. This unconventional laser diagnostic technique has promising ability to enhance accuracy of the quantitative scalar measurements in a point-wise single-shot fashion. In the presentation, we briefly describe an experimental methodology that generates transferable calibration standard for the routine implementation of the diagnostics in hydrocarbon flames. The diagnostic technology was applied to simultaneous measurements of temperature and chemical species in a swirl-stabilized turbulent flame with gaseous methane fuel at elevated pressure (17 atm). Statistical analyses of the space-/time-resolved thermochemical data provide insights into the nature of the mixing process and it impact on the subsequent combustion process in the model combustor.

  20. Diagnosing collisions of magnetized, high energy density plasma flows using a combination of collective Thomson scattering, Faraday rotation, and interferometry (invited).

    PubMed

    Swadling, G F; Lebedev, S V; Hall, G N; Patankar, S; Stewart, N H; Smith, R A; Harvey-Thompson, A J; Burdiak, G C; de Grouchy, P; Skidmore, J; Suttle, L; Suzuki-Vidal, F; Bland, S N; Kwek, K H; Pickworth, L; Bennett, M; Hare, J D; Rozmus, W; Yuan, J

    2014-11-01

    A suite of laser based diagnostics is used to study interactions of magnetised, supersonic, radiatively cooled plasma flows produced using the Magpie pulse power generator (1.4 MA, 240 ns rise time). Collective optical Thomson scattering measures the time-resolved local flow velocity and temperature across 7-14 spatial positions. The scattering spectrum is recorded from multiple directions, allowing more accurate reconstruction of the flow velocity vectors. The areal electron density is measured using 2D interferometry; optimisation and analysis are discussed. The Faraday rotation diagnostic, operating at 1053 nm, measures the magnetic field distribution in the plasma. Measurements obtained simultaneously by these diagnostics are used to constrain analysis, increasing the accuracy of interpretation.

  1. How Many People have Alcohol Use Disorders? Using the Harmful Dysfunction Analysis to Reconcile Prevalence Estimates in Two Community Surveys

    PubMed Central

    Wakefield, Jerome C.; Schmitz, Mark F.

    2014-01-01

    Community prevalence rates of alcohol use disorders (AUDs) provided by epidemiological studies using DSM-based diagnostic criteria pose several challenges: the rates appear implausibly high to many epidemiologists; they do not converge across similar studies; and, due to low service utilization by those diagnosed as disordered, they yield estimates of unmet need for services so high that credibility for planning purposes is jeopardized. For example, two early community studies using DSM diagnostic criteria, the Epidemiologic Catchment Area Study (ECA) and the National Comorbidity Survey (NCS), yielded lifetime AUD prevalence rates of 14 and 24%, respectively, with NCS unmet need for services 19% of the entire population. Attempts to address these challenges by adding clinical significance requirements to diagnostic criteria have proven unsuccessful. Hypothesizing that these challenges are due to high rates of false-positive diagnoses of problem drinking as AUDs, we test an alternative approach. We use the harmful dysfunction (HD) analysis of the concept of mental disorder as a guide to construct more valid criteria within the framework of the standard out-of-control model of AUD. The proposed HD criteria require harm and dysfunction, where harm can be any negative social, personal, or physical outcome, and dysfunction requires either withdrawal symptoms or inability to stop drinking. Using HD criteria, ECA and NCS lifetime prevalences converge to much-reduced rates of 6 and 6.8%, respectively. Due to higher service utilization rates, NCS lifetime unmet need is reduced to 3.4%. Service use and duration comparisons suggest that HD criteria possess increased diagnostic validity. Moreover, HD criteria eliminate 90% of transient teenage drinking from disorder status. The HD version of the out-of-control model thus potentially resolves the three classic prevalence challenges while offering a more rigorous approach to distinguishing AUDs from problematic drinking. PMID:24550847

  2. A POD reduced order model for resolving angular direction in neutron/photon transport problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buchan, A.G., E-mail: andrew.buchan@imperial.ac.uk; Calloo, A.A.; Goffin, M.G.

    2015-09-01

    This article presents the first Reduced Order Model (ROM) that efficiently resolves the angular dimension of the time independent, mono-energetic Boltzmann Transport Equation (BTE). It is based on Proper Orthogonal Decomposition (POD) and uses the method of snapshots to form optimal basis functions for resolving the direction of particle travel in neutron/photon transport problems. A unique element of this work is that the snapshots are formed from the vector of angular coefficients relating to a high resolution expansion of the BTE's angular dimension. In addition, the individual snapshots are not recorded through time, as in standard POD, but instead theymore » are recorded through space. In essence this work swaps the roles of the dimensions space and time in standard POD methods, with angle and space respectively. It is shown here how the POD model can be formed from the POD basis functions in a highly efficient manner. The model is then applied to two radiation problems; one involving the transport of radiation through a shield and the other through an infinite array of pins. Both problems are selected for their complex angular flux solutions in order to provide an appropriate demonstration of the model's capabilities. It is shown that the POD model can resolve these fluxes efficiently and accurately. In comparison to high resolution models this POD model can reduce the size of a problem by up to two orders of magnitude without compromising accuracy. Solving times are also reduced by similar factors.« less

  3. SEMINAR PUBLICATION: MANAGING ENVIRONMENTAL PROBLEMS AT INACTIVE AND ABANDONED METALS MINE SITES

    EPA Science Inventory

    Environmental problems associated with abandoned and inactive mines are addressed along with some approaches to resolving those problems, including case studies demonstrating technologies that have worked. New technologies being investigated are addressed also.

  4. Indoor Air Quality Problem Solving Tool

    EPA Pesticide Factsheets

    Use the IAQ Problem Solving Tool to learn about the connection between health complaints and common solutions in schools. This resource provides an easy, step-by-step process to start identifying and resolving IAQ problems found at your school.

  5. Laser-plasma interaction experiments and diagnostics at NRL (Naval Research Laboratory). Memorandum report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ripin, B.H.; Grun, J.; Herbst, M.J.

    Laser plasma interaction experiments have now advanced to the point where very quantitative measurements are required to elucidate the physic issues important for laser fusion and other applications. Detailed time-resolved knowledge of the plasma density, temperature, velocity gradients, spatial structure, heat flow characteristics, radiation emission, etc, are needed over tremendou ranges of plasma density and temperature. Moreover, the time scales are very short, aggrevating the difficulty of the measurements further. Nonetheless, such substantial progress has been made in diagnostic development during the past few years that we are now able to do well diagnosed experiments. In this paper the authorsmore » review recent diagnostic developments for laser-plasma interactions, outline their regimes of applicability, and show examples of their utility. In addition to diagnostics for the high densities and temperature characteristic of laser fusion physics studies, diagnostics designed to study the two-stream interactions of laser created plasma flowing through an ambient low density plasma will be described.« less

  6. Recent developments in Förster resonance energy transfer (FRET) diagnostics using quantum dots.

    PubMed

    Geißler, Daniel; Hildebrandt, Niko

    2016-07-01

    The exceptional photophysical properties and the nanometric dimensions of colloidal semiconductor quantum dots (QD) have strongly attracted the bioanalytical community over the last approximately 20 y. In particular, the integration of QDs in the analysis of biological components and interactions, and the related diagnostics using Förster resonance energy transfer (FRET), have allowed researchers to significantly improve and diversify fluorescence-based biosensing. In this TRENDS article, we review some recent developments in QD-FRET biosensing that have implemented this technology in electronic consumer products, multiplexed analysis, and detection without light excitation for diagnostic applications. In selected examples of smartphone-based imaging, single- and multistep FRET, steady-state and time-resolved spectroscopy, and bio/chemiluminescence detection of QDs used as both FRET donors and acceptors, we highlight the advantages of QD-based FRET biosensing for multiplexed and sensitive diagnostics. Graphical Abstract Quantum dots (QDs) can be applied as donors and/or acceptors for Förster resonance energy transfer- (FRET-) based biosensing for multiplexed and sensitive diagnostics in various assay formats.

  7. Reliability and Validity of a Procedure to Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    1990-01-01

    The reliability and validity of a procedure to measure diagnostic-reasoning and problem-solving skills taught in predoctoral orthodontic education were studied using 68 second year dental students. The procedure includes stimulus material and 33 multiple-choice items. It is a feasible way of assessing problem-solving skills in dentistry education…

  8. Integrating Hospital-Acquired Lessons into Community Health Practice: Optimizing Antimicrobial Use in Bangalore

    ERIC Educational Resources Information Center

    Biswas, Rakesh; Dineshan, Vineeth; Narasimhamurthy, N. S.; Kasthuri, A. S.

    2007-01-01

    Introduction: Even as antimicrobial resistance is a serious public health concern worldwide, the uncertainties of diagnosis and treatment of fever strongly influence community practitioners toward prescribing antibiotics. To help community practitioners resolve their diagnostic questions and reduce the unnecessary use of antibiotics for viral…

  9. Benchtop Energetics: Research Progress, Concept Evaluation, and Apparatus Development

    DTIC Science & Technology

    2012-01-31

    have removed the relay imaging optics, and currently use a single 40 cm focal length lens, placed ≈ 48 cm from the target surface, to image the...24 1. Photographic Flyer Velocity Measurements ......................................... 24 2. Impact Luminescence Flyer...27 4. Time-Resolved Impact Luminescence Spectroscopy ........................... 28 E. Mass Spectrometric Diagnostics

  10. Unusual scintigraphic appearances of a mobile accessory lobe of the liver. [/sup 67/Ga; /sup 99m/Tc-sulfur colloid; /sup 99m/Tc-dihydrothioctic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bingham, J.B.; Maisey, M.N.

    1978-11-01

    Accessory hepatic lobules are an uncommon occurrence. In a gallium scan, a highly mobile, asymptomatic liver lobule gave rise to diagnostic confusion. It was resolved by the use of multiple radiopharmaceuticals.

  11. Diagnostic reasoning strategies and diagnostic success.

    PubMed

    Coderre, S; Mandin, H; Harasym, P H; Fick, G H

    2003-08-01

    Cognitive psychology research supports the notion that experts use mental frameworks or "schemes", both to organize knowledge in memory and to solve clinical problems. The central purpose of this study was to determine the relationship between problem-solving strategies and the likelihood of diagnostic success. Think-aloud protocols were collected to determine the diagnostic reasoning used by experts and non-experts when attempting to diagnose clinical presentations in gastroenterology. Using logistic regression analysis, the study found that there is a relationship between diagnostic reasoning strategy and the likelihood of diagnostic success. Compared to hypothetico-deductive reasoning, the odds of diagnostic success were significantly greater when subjects used the diagnostic strategies of pattern recognition and scheme-inductive reasoning. Two other factors emerged as independent determinants of diagnostic success: expertise and clinical presentation. Not surprisingly, experts outperformed novices, while the content area of the clinical cases in each of the four clinical presentations demonstrated varying degrees of difficulty and thus diagnostic success. These findings have significant implications for medical educators. It supports the introduction of "schemes" as a means of enhancing memory organization and improving diagnostic success.

  12. Three computational mise-en-scènes of red- and blue-shifted hydrogen bonding motifs: Concept of negative intramolecular coupling-What else?

    NASA Astrophysics Data System (ADS)

    Kryachko, Eugene S.

    This work is a kind of attempt to rethink some problems which are related to the blue-shifted "hydrogen bonds" and which have been left in the past decade as not yet fully resolved. The impetus for such rethink is originated from the three computational mise-en-scènes on red- and blue-shifted hydrogen bonding motifs, which are aimed to be thoroughly studied in this work, thus resolving the above problems.

  13. Success in Science, Success in Collaboration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Mariann R.

    2016-08-25

    This is a series of four different scientific problems which were resolved through collaborations. They are: "Better flow cytometry through novel focusing technology", "Take Off ®: Helping the Agriculture Industry Improve the Viability of Sustainable, Large-Production Crops", "The National Institutes of Health's Models of Infectious Disease Agent Study (MIDAS)", and "Expanding the capabilities of SOLVE/RESOLVE through the PHENIX Consortium." For each one, the problem is listed, the solution, advantages, bottom line, then information about the collaboration including: developing the technology, initial success, and continued success.

  14. Evidence-informed recommendations to reduce dissemination bias in clinical research: conclusions from the OPEN (Overcome failure to Publish nEgative fiNdings) project based on an international consensus meeting.

    PubMed

    Meerpohl, Joerg J; Schell, Lisa K; Bassler, Dirk; Gallus, Silvano; Kleijnen, Jos; Kulig, Michael; La Vecchia, Carlo; Marušić, Ana; Ravaud, Philippe; Reis, Andreas; Schmucker, Christine; Strech, Daniel; Urrútia, Gerard; Wager, Elizabeth; Antes, Gerd

    2015-05-05

    Dissemination bias in clinical research severely impedes informed decision-making not only for healthcare professionals and patients, but also for funders, research ethics committees, regulatory bodies and other stakeholder groups that make health-related decisions. Decisions based on incomplete and biased evidence cannot only harm people, but may also have huge financial implications by wasting resources on ineffective or harmful diagnostic and therapeutic measures, and unnecessary research. Owing to involvement of multiple stakeholders, it remains easy for any single group to assign responsibility for resolving the problem to others. To develop evidence-informed general and targeted recommendations addressing the various stakeholders involved in knowledge generation and dissemination to help overcome the problem of dissemination bias on the basis of previously collated evidence. Based on findings from systematic reviews, document analyses and surveys, we developed general and targeted draft recommendations. During a 2-day workshop in summer 2013, these draft recommendations were discussed with external experts and key stakeholders, and refined following a rigorous and transparent methodological approach. Four general, overarching recommendations applicable to all or most stakeholder groups were formulated, addressing (1) awareness raising, (2) implementation of targeted recommendations, (3) trial registration and results posting, and (4) systematic approaches to evidence synthesis. These general recommendations are complemented and specified by 47 targeted recommendations tailored towards funding agencies, pharmaceutical and device companies, research institutions, researchers (systematic reviewers and trialists), research ethics committees, trial registries, journal editors and publishers, regulatory agencies, benefit (health technology) assessment institutions and legislators. Despite various recent examples of dissemination bias and several initiatives to reduce it, the problem of dissemination bias has not been resolved. Tailored recommendations based on a comprehensive approach will hopefully help increase transparency in biomedical research by overcoming the failure to disseminate negative findings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. RadPath: A Web-based System for Integrating and Correlating Radiology and Pathology Findings During Cancer Diagnosis.

    PubMed

    Arnold, Corey W; Wallace, W Dean; Chen, Shawn; Oh, Andrea; Abtin, Fereidoun; Genshaft, Scott; Binder, Scott; Aberle, Denise; Enzmann, Dieter

    2016-01-01

    The current paradigm of cancer diagnosis involves uncoordinated communication of findings from radiology and pathology to downstream physicians. Discordance between these findings can require additional time from downstream users to resolve, or given incorrect resolution, may adversely impact treatment decisions. To mitigate this problem, we developed a web-based system, called RadPath, for correlating and integrating radiology and pathology reporting. RadPath includes interfaces to our institution's clinical information systems, which are used to retrieve reports, images, and test results that are structured into an interactive compendium for a diagnostic patient case. The system includes an editing interface for physicians, allowing for the inclusion of additional clinical data, as well as the ability to retrospectively correlate and contextualize imaging findings following pathology diagnosis. During pilot deployment and testing over the course of 1 year, physicians at our institution have completed 60 RadPath cases, requiring an average of 128 seconds from a radiologist and an average of 93 seconds from a pathologist per case. Several technical and workflow challenges were encountered during development, including interfacing with diverse clinical information systems, automatically structuring report contents, and determining the appropriate physicians to create RadPath summaries. Reaction to RadPath has been positive, with users valuing the system's ability to consolidate diagnostic information. With the increasing complexity of medicine and the movement toward team-based disease management, there is a need for improved clinical communication and information exchange. RadPath provides a platform for generating coherent and correlated diagnostic summaries in cancer diagnosis with minimal additional effort from physicians. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Clue Insensitivity in Remote Associates Test Problem Solving

    ERIC Educational Resources Information Center

    Smith, Steven M.; Sifonis, Cynthia M.; Angello, Genna

    2012-01-01

    Does spreading activation from incidentally encountered hints cause incubation effects? We used Remote Associates Test (RAT) problems to examine effects of incidental clues on impasse resolution. When solution words were seen incidentally 3-sec before initially unsolved problems were retested, more problems were resolved (Experiment 1). When…

  17. Time-resolved UV-excited microarray reader for fluorescence energy transfer (FRET) measurements

    NASA Astrophysics Data System (ADS)

    Orellana, Adelina; Hokkanen, Ari P.; Pastinen, Tomi; Takkinen, Kristina; Soderlund, Hans

    2001-05-01

    Analytical systems based on immunochemistry are largely used in medical diagnostics and in biotechnology. There is a significant pressure to develop the present assay formats to become easier to use, faster, and less reagent consuming. Further developments towards high density array--like multianalyte measurement systems would be valuable. To this aim we have studied the applicability of fluorescence resonance energy transfer and time-resolved fluorescence resonance energy transfer in immunoassays on microspots and in microwells. We have used engineered recombinant antibodies detecting the pentameric protein CRP as a model analyte system, and tested different assay formats. We describe also the construction of a time-resolved scanning epifluorometer with which we could measure the FRET interaction between the slow fluorescence decay from europium chelates and its energy transfer to the rapidly decaying fluorophore Cy5.

  18. Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps [Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore EBIT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hell, N.; Beiersdorfer, P.; Magee, E. W.

    2016-08-04

    Here, we report the calibration of the Orion High-Resolution X-ray (OHREX) imaging crystal spectrometer at the EBIT-I electron beam ion trap at Livermore. Two such instruments, dubbed OHREX-1 and OHREX-2, are fielded for plasma diagnostics at the Orion laser facility in the United Kingdom. The OHREX spectrometer can simultaneously house two spherically bent crystals with a radius of curvature of r=67.2 cm. The focusing properties of the spectrometer allow both for larger distance to the source due to the increase in collected light and for observation of extended sources. OHREX is designed to cover a 2.5–3 degree spectral range atmore » Bragg angles around 51.3 degree. The typically high resolving powers at these large Bragg angles are ideally suited for line shape diagnostics. For instance, the nominal resolving power of the instrument (> 10000) is much higher than the effective resolving power associated with the Doppler broadening due to the temperature of the trapped ions in EBIT-I. The effective resolving power is only around 3000 at typical EBIT-I conditions, which nevertheless is sufficient to set up and test the instrument’s spectral characteristics. We have calibrated the spectral range for a number of crystals using well known reference lines in first and second order, and derived the ion temperatures from these lines. We have also made use of the 50µm size of the EBIT-I source width to characterize the spatial focusing of the spectrometer.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unseren, M.A.

    This report proposes a method for resolving the kinematic redundancy of a serial link manipulator moving in a three-dimensional workspace. The underspecified problem of solving for the joint velocities based on the classical kinematic velocity model is transformed into a well-specified problem. This is accomplished by augmenting the original model with additional equations which relate a new vector variable quantifying the redundant degrees of freedom (DOF) to the joint velocities. The resulting augmented system yields a well specified solution for the joint velocities. Methods for selecting the redundant DOF quantifying variable and the transformation matrix relating it to the jointmore » velocities are presented so as to obtain a minimum Euclidean norm solution for the joint velocities. The approach is also applied to the problem of resolving the kinematic redundancy at the acceleration level. Upon resolving the kinematic redundancy, a rigid body dynamical model governing the gross motion of the manipulator is derived. A control architecture is suggested which according to the model, decouples the Cartesian space DOF and the redundant DOF.« less

  20. Diagnostic tolerance for missing sensor data

    NASA Technical Reports Server (NTRS)

    Scarl, Ethan A.

    1989-01-01

    For practical automated diagnostic systems to continue functioning after failure, they must not only be able to diagnose sensor failures but also be able to tolerate the absence of data from the faulty sensors. It is shown that conventional (associational) diagnostic methods will have combinatoric problems when trying to isolate faulty sensors, even if they adequately diagnose other components. Moreover, attempts to extend the operation of diagnostic capability past sensor failure will necessarily compound those difficulties. Model-based reasoning offers a structured alternative that has no special problems diagnosing faulty sensors and can operate gracefully when sensor data is missing.

  1. Rocket Engine Oscillation Diagnostics

    NASA Technical Reports Server (NTRS)

    Nesman, Tom; Turner, James E. (Technical Monitor)

    2002-01-01

    Rocket engine oscillating data can reveal many physical phenomena ranging from unsteady flow and acoustics to rotordynamics and structural dynamics. Because of this, engine diagnostics based on oscillation data should employ both signal analysis and physical modeling. This paper describes an approach to rocket engine oscillation diagnostics, types of problems encountered, and example problems solved. Determination of design guidelines and environments (or loads) from oscillating phenomena is required during initial stages of rocket engine design, while the additional tasks of health monitoring, incipient failure detection, and anomaly diagnostics occur during engine development and operation. Oscillations in rocket engines are typically related to flow driven acoustics, flow excited structures, or rotational forces. Additional sources of oscillatory energy are combustion and cavitation. Included in the example problems is a sampling of signal analysis tools employed in diagnostics. The rocket engine hardware includes combustion devices, valves, turbopumps, and ducts. Simple models of an oscillating fluid system or structure can be constructed to estimate pertinent dynamic parameters governing the unsteady behavior of engine systems or components. In the example problems it is shown that simple physical modeling when combined with signal analysis can be successfully employed to diagnose complex rocket engine oscillatory phenomena.

  2. Stochastic downscaling of numerically simulated spatial rain and cloud fields using a transient multifractal approach

    NASA Astrophysics Data System (ADS)

    Nogueira, M.; Barros, A. P.; Miranda, P. M.

    2012-04-01

    Atmospheric fields can be extremely variable over wide ranges of spatial scales, with a scale ratio of 109-1010 between largest (planetary) and smallest (viscous dissipation) scale. Furthermore atmospheric fields with strong variability over wide ranges in scale most likely should not be artificially split apart into large and small scales, as in reality there is no scale separation between resolved and unresolved motions. Usually the effects of the unresolved scales are modeled by a deterministic bulk formula representing an ensemble of incoherent subgrid processes on the resolved flow. This is a pragmatic approach to the problem and not the complete solution to it. These models are expected to underrepresent the small-scale spatial variability of both dynamical and scalar fields due to implicit and explicit numerical diffusion as well as physically based subgrid scale turbulent mixing, resulting in smoother and less intermittent fields as compared to observations. Thus, a fundamental change in the way we formulate our models is required. Stochastic approaches equipped with a possible realization of subgrid processes and potentially coupled to the resolved scales over the range of significant scale interactions range provide one alternative to address the problem. Stochastic multifractal models based on the cascade phenomenology of the atmosphere and its governing equations in particular are the focus of this research. Previous results have shown that rain and cloud fields resulting from both idealized and realistic numerical simulations display multifractal behavior in the resolved scales. This result is observed even in the absence of scaling in the initial conditions or terrain forcing, suggesting that multiscaling is a general property of the nonlinear solutions of the Navier-Stokes equations governing atmospheric dynamics. Our results also show that the corresponding multiscaling parameters for rain and cloud fields exhibit complex nonlinear behavior depending on large scale parameters such as terrain forcing and mean atmospheric conditions at each location, particularly mean wind speed and moist stability. A particularly robust behavior found is the transition of the multiscaling parameters between stable and unstable cases, which has a clear physical correspondence to the transition from stratiform to organized (banded) convective regime. Thus multifractal diagnostics of moist processes are fundamentally transient and should provide a physically robust basis for the downscaling and sub-grid scale parameterizations of moist processes. Here, we investigate the possibility of using a simplified computationally efficient multifractal downscaling methodology based on turbulent cascades to produce statistically consistent fields at scales higher than the ones resolved by the model. Specifically, we are interested in producing rainfall and cloud fields at spatial resolutions necessary for effective flash flood and earth flows forecasting. The results are examined by comparing downscaled field against observations, and tendency error budgets are used to diagnose the evolution of transient errors in the numerical model prediction which can be attributed to aliasing.

  3. Clarification process: Resolution of decision-problem conditions

    NASA Technical Reports Server (NTRS)

    Dieterly, D. L.

    1980-01-01

    A model of a general process which occurs in both decisionmaking and problem-solving tasks is presented. It is called the clarification model and is highly dependent on information flow. The model addresses the possible constraints of individual indifferences and experience in achieving success in resolving decision-problem conditions. As indicated, the application of the clarification process model is only necessary for certain classes of the basic decision-problem condition. With less complex decision problem conditions, certain phases of the model may be omitted. The model may be applied across a wide range of decision problem conditions. The model consists of two major components: (1) the five-phase prescriptive sequence (based on previous approaches to both concepts) and (2) the information manipulation function (which draws upon current ideas in the areas of information processing, computer programming, memory, and thinking). The two components are linked together to provide a structure that assists in understanding the process of resolving problems and making decisions.

  4. Are health care provider organizations ready to tackle diagnostic error? A survey of Leapfrog-participating hospitals.

    PubMed

    Newman-Toker, David E; Austin, J Matthew; Derk, Jordan; Danforth, Melissa; Graber, Mark L

    2017-06-27

    A 2015 National Academy of Medicine report on improving diagnosis in health care made recommendations for direct action by hospitals and health systems. Little is known about how health care provider organizations are addressing diagnostic safety/quality. This study is an anonymous online survey of safety professionals from US hospitals and health systems in July-August 2016. The survey was sent to those attending a Leapfrog Group webinar on misdiagnosis (n=188). The instrument was focused on knowledge, attitudes, and capability to address diagnostic errors at the institutional level. Overall, 61 (32%) responded, including community hospitals (42%), integrated health networks (25%), and academic centers (21%). Awareness was high, but commitment and capability were low (31% of leaders understand the problem; 28% have sufficient safety resources; and 25% have made diagnosis a top institutional safety priority). Ongoing efforts to improve diagnostic safety were sparse and mostly included root cause analysis and peer review feedback around diagnostic errors. The top three barriers to addressing diagnostic error were lack of awareness of the problem, lack of measures of diagnostic accuracy and error, and lack of feedback on diagnostic performance. The top two tools viewed as critically important for locally tackling the problem were routine feedback on diagnostic performance and culture change to emphasize diagnostic safety. Although hospitals and health systems appear to be aware of diagnostic errors as a major safety imperative, most organizations (even those that appear to be making a strong commitment to patient safety) are not yet doing much to improve diagnosis. Going forward, efforts to activate health care organizations will be essential to improving diagnostic safety.

  5. A Primer on Receiver Operating Characteristic Analysis and Diagnostic Efficiency Statistics for Pediatric Psychology: We Are Ready to ROC

    PubMed Central

    2014-01-01

    Objective To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Method Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Results Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. Conclusions This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses. PMID:23965298

  6. A primer on receiver operating characteristic analysis and diagnostic efficiency statistics for pediatric psychology: we are ready to ROC.

    PubMed

    Youngstrom, Eric A

    2014-03-01

    To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses.

  7. Must "Hard Problems" Be Hard?

    ERIC Educational Resources Information Center

    Kolata, Gina

    1985-01-01

    To determine how hard it is for computers to solve problems, researchers have classified groups of problems (polynomial hierarchy) according to how much time they seem to require for their solutions. A difficult and complex proof is offered which shows that a combinatorial approach (using Boolean circuits) may resolve the problem. (JN)

  8. Highly time-resolved imaging of combustion and pyrolysis product concentrations in solid fuel combustion: NO formation in a burning cigarette.

    PubMed

    Zimmermann, Ralf; Hertz-Schünemann, Romy; Ehlert, Sven; Liu, Chuan; McAdam, Kevin; Baker, Richard; Streibel, Thorsten

    2015-02-03

    The highly dynamic, heterogeneous combustion process within a burning cigarette was investigated by a miniaturized extractive sampling probe (microprobe) coupled to photoionization mass spectrometry using soft laser single photon ionization (SPI) for online real-time detection of molecular ions of combustion and pyrolysis products. Research cigarettes smoked by a smoking machine are used as a reproducible model system for solid-state biomass combustion, which up to now is not addressable by current combustion-diagnostic tools. By combining repetitively recorded online measurement sequences from different sampling locations in an imaging approach, highly time- and space-resolved quantitative distribution maps of, e.g., nitrogen monoxide, benzene, and oxygen concentrations were obtained at a near microscopic level. The obtained quantitative distribution maps represent a time-resolved, movie-like imaging of the respective compound's formation and destruction zones in the various combustion and pyrolysis regions of a cigarette during puffing. Furthermore, spatially resolved kinetic data were ascertainable. The here demonstrated methodology can also be applied to various heterogenic combustion/pyrolysis or reaction model systems, such as fossil- or biomass-fuel pellet combustion or to a positional resolved analysis of heterogenic catalytic reactions.

  9. Remote sensing; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

    NASA Technical Reports Server (NTRS)

    Menzies, Robert T. (Editor)

    1986-01-01

    Advances in optical technology for remote sensing are discussed in reviews and reports of recent experimental investigations. Topics examined include industrial applications, laser diagnostics for combustion research, laser remote sensing for ranging and altimetry, and imaging systems for terrestrial remote sensing from space. Consideration is given to LIF in forensic diagnostics, time-resolved laser-induced-breakdown spectrometry for rapid analysis of alloys, CARS in practical combustion environments, airborne inertial surveying using laser tracking and profiling techniques, earth-resources instrumentation for the EOS polar platform of the Space Station, and the SAR for EOS.

  10. Time for a change: addressing R&D and commercialization challenges for antibacterials.

    PubMed

    Payne, David J; Miller, Linda Federici; Findlay, David; Anderson, James; Marks, Lynn

    2015-06-05

    The antibacterial therapeutic area has been described as the perfect storm. Resistance is increasing to the point that our hospitals encounter patients infected with untreatable pathogens, the overall industry pipeline is described as dry and most multinational pharmaceutical companies have withdrawn from the area. Major contributing factors to the declining antibacterial industry pipeline include scientific challenges, clinical/regulatory hurdles and low return on investment. This paper examines these challenges and proposes approaches to address them. There is a need for a broader scientific agenda to explore new approaches to discover and develop antibacterial agents. Additionally, ideas of how industry and academia could be better integrated will be presented. While promising progress in the regulatory environment has been made, more streamlined regulatory paths are still required and the solutions will lie in global harmonization and clearly defined guidance. Creating the right incentives for antibacterial research and development is critical and a new commercial model for antibacterial agents will be proposed. One key solution to help resolve both the problem of antimicrobial resistance (AMR) and lack of new drug development are rapid, cost-effective, accurate point of care diagnostics that will transform antibacterial prescribing and enable more cost-effective and efficient antibacterial clinical trials. The challenges of AMR are too great for any one group to resolve and success will require leadership and partnerships among academia, industry and governments globally. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  11. Multi-Compartment T2 Relaxometry Using a Spatially Constrained Multi-Gaussian Model

    PubMed Central

    Raj, Ashish; Pandya, Sneha; Shen, Xiaobo; LoCastro, Eve; Nguyen, Thanh D.; Gauthier, Susan A.

    2014-01-01

    The brain’s myelin content can be mapped by T2-relaxometry, which resolves multiple differentially relaxing T2 pools from multi-echo MRI. Unfortunately, the conventional fitting procedure is a hard and numerically ill-posed problem. Consequently, the T2 distributions and myelin maps become very sensitive to noise and are frequently difficult to interpret diagnostically. Although regularization can improve stability, it is generally not adequate, particularly at relatively low signal to noise ratio (SNR) of around 100–200. The purpose of this study was to obtain a fitting algorithm which is able to overcome these difficulties and generate usable myelin maps from noisy acquisitions in a realistic scan time. To this end, we restrict the T2 distribution to only 3 distinct resolvable tissue compartments, modeled as Gaussians: myelin water, intra/extra-cellular water and a slow relaxing cerebrospinal fluid compartment. We also impose spatial smoothness expectation that volume fractions and T2 relaxation times of tissue compartments change smoothly within coherent brain regions. The method greatly improves robustness to noise, reduces spatial variations, improves definition of white matter fibers, and enhances detection of demyelinating lesions. Due to efficient design, the additional spatial aspect does not cause an increase in processing time. The proposed method was applied to fast spiral acquisitions on which conventional fitting gives uninterpretable results. While these fast acquisitions suffer from noise and inhomogeneity artifacts, our preliminary results indicate the potential of spatially constrained 3-pool T2 relaxometry. PMID:24896833

  12. Content Analysis of Student Essays after Attending a Problem-Based Learning Course: Facilitating the Development of Critical Thinking and Communication Skills in Japanese Nursing Students.

    PubMed

    Itatani, Tomoya; Nagata, Kyoko; Yanagihara, Kiyoko; Tabuchi, Noriko

    2017-08-22

    The importance of active learning has continued to increase in Japan. The authors conducted classes for first-year students who entered the nursing program using the problem-based learning method which is a kind of active learning. Students discussed social topics in classes. The purposes of this study were to analyze the post-class essay, describe logical and critical thinking after attended a Problem-Based Learning (PBL) course. The authors used Mayring's methodology for qualitative content analysis and text mining. In the description about the skills required to resolve social issues, seven categories were extracted: (recognition of diverse social issues), (attitudes about resolving social issues), (discerning the root cause), (multi-lateral information processing skills), (making a path to resolve issues), (processivity in dealing with issues), and (reflecting). In the description about communication, five categories were extracted: (simple statement), (robust theories), (respecting the opponent), (communication skills), and (attractive presentations). As the result of text mining, the words extracted more than 100 times included "issue," "society," "resolve," "myself," "ability," "opinion," and "information." Education using PBL could be an effective means of improving skills that students described, and communication in general. Some students felt difficulty of communication resulting from characteristics of Japanese.

  13. Motivators for resolving or seeking help for gambling problems: a review of the empirical literature.

    PubMed

    Suurvali, Helen; Hodgins, David C; Cunningham, John A

    2010-03-01

    This literature review summarizes recent empirical research on the reasons disordered gamblers try, through treatment or otherwise, to resolve or reduce their gambling problems. Relevant databases and bibliographies were searched for English-language studies, published since 1998, that asked gamblers themselves about motivators for action. Found were ten studies addressing reasons for trying to resolve or reduce gambling problems, five addressing reasons for seeking help and four addressing reasons for requesting self-exclusion from casinos. Help-seeking occurred largely in response to gambling-related harms (especially financial problems, relationship issues and negative emotions) that had already happened or that were imminent. Resolution was often motivated by the same kinds of harms but evaluation/decision-making and changes in lifestyle or environment played a more prominent role. Self-exclusion was motivated by harms, evaluation/decision-making and a wish to regain control. Awareness and educational materials could incorporate messages that might encourage heavy gamblers to make changes before harms became too great. Intervention development could also benefit from more research on the motivators leading to successful (vs. failed) resolution, as well as on the ways in which disordered gamblers are able to overcome specific barriers to seeking help or reaching resolution.

  14. Spatially resolved density and ionization measurements of shocked foams using x-ray fluorescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacDonald, M. J.; Keiter, P. A.; Montgomery, D. S.

    2016-09-22

    We present experiments at the Trident laser facility demonstrating the use of x-ray fluorescence (XRF) to simultaneously measure density, ionization state populations, and electron temperature in shocked foams. An imaging x-ray spectrometer was used to obtain spatially-resolved measurements of Ti K-more » $$\\alpha$$ emission. Density profiles were measured from K-$$\\alpha$$ intensity. Ti ionization state distributions and electron temperatures were inferred by fitting K-$$\\alpha$$ spectra to spectra from CRETIN simulations. This study shows that XRF provides a powerful tool to complement other diagnostics to make equation of state measurements of shocked materials containing a suitable tracer element.« less

  15. Enhanced visible and near-infrared capabilities of the JET mirror-linked divertor spectroscopy system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lomanowski, B. A., E-mail: b.a.lomanowski@durham.ac.uk; Sharples, R. M.; Meigs, A. G.

    2014-11-15

    The mirror-linked divertor spectroscopy diagnostic on JET has been upgraded with a new visible and near-infrared grating and filtered spectroscopy system. New capabilities include extended near-infrared coverage up to 1875 nm, capturing the hydrogen Paschen series, as well as a 2 kHz frame rate filtered imaging camera system for fast measurements of impurity (Be II) and deuterium Dα, Dβ, Dγ line emission in the outer divertor. The expanded system provides unique capabilities for studying spatially resolved divertor plasma dynamics at near-ELM resolved timescales as well as a test bed for feasibility assessment of near-infrared spectroscopy.

  16. Birefringence and vascular imaging of in vivo human skin by Jones-matrix optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Li, En; Makita, Shuichi; Hong, Young-Joo; Kasaragod, Deepa; Yasuno, Yoshiaki

    2017-02-01

    A customized 1310-nm Jones-matrix optical coherence tomography (JM-OCT) for dermatological investigation was constructed and used for in vivo normal human skin tissue imaging. This system can simultaneously measure the threedimensional depth-resolved local birefringence, complex-correlation based OCT angiography (OCT-A), degree-ofpolarization- uniformity (DOPU) and scattering OCT intensity. By obtaining these optical properties of tissue, the morphology, vasculature, and collagen content of skin can be deduced and visualized. Structures in the deep layers of the epithelium were observed with depth-resolved local birefringence and polarization uniformity images. These results suggest high diagnostic and investigative potential of JM-OCT for dermatology.

  17. Diagnostics for the Analysis of Surface Chemistry Effects on Composite Energetic Material Reactions

    DTIC Science & Technology

    2015-10-30

    integration time) and a NETZSCH STA 449 Jupiter that will allow for consistency and efficiency with its automatic 20 sample changer. (2) Together these...Purchase of the NETZSCH STA 449 Jupiter (DSC-TGA) to resolve reaction kinetics under equilibrium conditions. Images of this instrumentation are included in

  18. Spatially resolved bimodal spectroscopy for classification/evaluation of mouse skin inflammatory and pre-cancerous stages

    NASA Astrophysics Data System (ADS)

    Díaz-Ayil, Gilberto; Amouroux, Marine; Clanché, Fabien; Granjon, Yves; Blondel, Walter C. P. M.

    2009-07-01

    Spatially-resolved bimodal spectroscopy (multiple AutoFluorescence AF excitation and Diffuse Reflectance DR), was used in vivo to discriminate various healthy and precancerous skin stages in a pre-clinical model (UV-irradiated mouse): Compensatory Hyperplasia CH, Atypical Hyperplasia AH and Dysplasia D. A specific data preprocessing scheme was applied to intensity spectra (filtering, spectral correction and intensity normalization), and several sets of spectral characteristics were automatically extracted and selected based on their discrimination power, statistically tested for every pair-wise comparison of histological classes. Data reduction with Principal Components Analysis (PCA) was performed and 3 classification methods were implemented (k-NN, LDA and SVM), in order to compare diagnostic performance of each method. Diagnostic performance was studied and assessed in terms of Sensibility (Se) and Specificity (Sp) as a function of the selected features, of the combinations of 3 different inter-fibres distances and of the numbers of principal components, such that: Se and Sp ~ 100% when discriminating CH vs. others; Sp ~ 100% and Se > 95% when discriminating Healthy vs. AH or D; Sp ~ 74% and Se ~ 63% for AH vs. D.

  19. Novel energy resolving x-ray pinhole camera on Alcator C-Mod.

    PubMed

    Pablant, N A; Delgado-Aparicio, L; Bitter, M; Brandstetter, S; Eikenberry, E; Ellis, R; Hill, K W; Hofer, P; Schneebeli, M

    2012-10-01

    A new energy resolving x-ray pinhole camera has been recently installed on Alcator C-Mod. This diagnostic is capable of 1D or 2D imaging with a spatial resolution of ≈1 cm, an energy resolution of ≈1 keV in the range of 3.5-15 keV and a maximum time resolution of 5 ms. A novel use of a Pilatus 2 hybrid-pixel x-ray detector [P. Kraft et al., J. Synchrotron Rad. 16, 368 (2009)] is employed in which the lower energy threshold of individual pixels is adjusted, allowing regions of a single detector to be sensitive to different x-ray energy ranges. Development of this new detector calibration technique was done as a collaboration between PPPL and Dectris Ltd. The calibration procedure is described, and the energy resolution of the detector is characterized. Initial data from this installation on Alcator C-Mod is presented. This diagnostic provides line-integrated measurements of impurity emission which can be used to determine impurity concentrations as well as the electron energy distribution.

  20. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade.

    PubMed

    Chernyshova, M; Malinowski, K; Czarski, T; Wojeński, A; Vezinet, D; Poźniak, K T; Kasprowicz, G; Mazon, D; Jardin, A; Herrmann, A; Kowalska-Strzęciwilk, E; Krawczyk, R; Kolasiński, P; Zabołotny, W; Zienkiewicz, P

    2016-11-01

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  1. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Chernyshova, M.; Malinowski, K.; Czarski, T.; Wojeński, A.; Vezinet, D.; Poźniak, K. T.; Kasprowicz, G.; Mazon, D.; Jardin, A.; Herrmann, A.; Kowalska-Strzeciwilk, E.; Krawczyk, R.; Kolasiński, P.; Zabołotny, W.; Zienkiewicz, P.

    2016-11-01

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  2. Compact soft x-ray multichord camera: Design and initial operation

    NASA Astrophysics Data System (ADS)

    Franz, P.; Gadani, G.; Pasqualotto, R.; Marrelli, L.; Martin, P.; Spizzo, G.; Brunsell, P.; Chapman, B. E.; Paganucci, F.; Rossetti, P.; Xiao, C.

    2003-03-01

    A compact and low cost diagnostic for spatially resolved measurements of soft x-ray or total radiation emission has been designed and realized to be flexibly applied to different plasma physics experiments. Its reduced size (outer diameter=35 mm) makes it suited to a variety of devices. The line integrated emissivity (brightness) has been measured along up to 20 lines of sight, using an array of miniaturized silicon photodiodes. Preliminary prototypes of the diagnostic have been installed in the Madison Symmetric Torus reversed field pinch (RFP) device at University of Wisconsin and in the EXTRAP T2 RFP device at the Royal Institute of Technology in Stockholm. Application of the diagnostic to a gas-fed (argon, helium) magnetoplasma dynamic thruster (MPDT) with an external magnetic field will also be discussed.

  3. 45 CFR 95.610 - Submission of advance planning documents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and implementation; (v) A commitment to conduct/prepare the problem(s) needs assessment, feasibility... statement of the problem/need that the existing capabilities can not resolve, new or changed program..., planning activities/deliverables, State and contractor resource needs, planning project procurement...

  4. 45 CFR 95.610 - Submission of advance planning documents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and implementation; (v) A commitment to conduct/prepare the problem(s) needs assessment, feasibility... statement of the problem/need that the existing capabilities can not resolve, new or changed program..., planning activities/deliverables, State and contractor resource needs, planning project procurement...

  5. 45 CFR 95.610 - Submission of advance planning documents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and implementation; (v) A commitment to conduct/prepare the problem(s) needs assessment, feasibility... statement of the problem/need that the existing capabilities can not resolve, new or changed program..., planning activities/deliverables, State and contractor resource needs, planning project procurement...

  6. Torque and Learning and Behavior Problems in Children.

    ERIC Educational Resources Information Center

    Zendel, Ivan H.; Pihl, R. O.

    1980-01-01

    Findings indicate minimal differences, on diagnostic tests, between children who exhibited torque and those who did not. Torque is defined as the circling of any X in a clockwise direction. Torque is not associated with learning problems in school. Diagnostic utility of torque should be carefully considered. (Author)

  7. 42 CFR 493.1451 - Standard: Technical supervisor responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... testing samples; and (vi) Assessment of problem solving skills; and (9) Evaluating and documenting the... analysis and reporting of test results; (5) Resolving technical problems and ensuring that remedial actions...

  8. Brown Syndrome

    MedlinePlus

    ... Does Brown syndrome cause eye problems besides abnormal eye movements? In the more severely affected cases of Brown ... acquired and congenital cases. In congenital cases, the eye movement problem is usually constant and unlikely to resolve ...

  9. School Attendance Problems: Using the TQM Tools To Identify Root Causes.

    ERIC Educational Resources Information Center

    Weller, L. David

    2000-01-01

    Deming's principles and TQM problem-solving tools and techniques can be used to solve noninstructional problems such as vandalism, dropouts, and student absenteeism. This case study presents a model for principals to apply to identify root causes, resolve problems, and provide quality outcomes (at reduced cost) in noninstructional areas. (Contains…

  10. Problem-Solving Examples as Interactive Learning Objects for Educational Digital Libraries

    ERIC Educational Resources Information Center

    Brusilovsky, Peter; Yudelson, Michael; Hsiao, I-Han

    2009-01-01

    The paper analyzes three major problems encountered by our team as we endeavored to turn problem solving examples in the domain of programming into highly reusable educational activities, which could be included as first class objects in various educational digital libraries. It also suggests three specific approaches to resolving these problems,…

  11. Incremental planning to control a blackboard-based problem solver

    NASA Technical Reports Server (NTRS)

    Durfee, E. H.; Lesser, V. R.

    1987-01-01

    To control problem solving activity, a planner must resolve uncertainty about which specific long-term goals (solutions) to pursue and about which sequences of actions will best achieve those goals. A planner is described that abstracts the problem solving state to recognize possible competing and compatible solutions and to roughly predict the importance and expense of developing these solutions. With this information, the planner plans sequences of problem solving activities that most efficiently resolve its uncertainty about which of the possible solutions to work toward. The planner only details actions for the near future because the results of these actions will influence how (and whether) a plan should be pursued. As problem solving proceeds, the planner adds new details to the plan incrementally, and monitors and repairs the plan to insure it achieves its goals whenever possible. Through experiments, researchers illustrate how these new mechanisms significantly improve problem solving decisions and reduce overall computation. They briefly discuss current research directions, including how these mechanisms can improve a problem solver's real-time response and can enhance cooperation in a distributed problem solving network.

  12. High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

    NASA Technical Reports Server (NTRS)

    Ponseggi, B. G. (Editor); Johnson, H. C. (Editor)

    1985-01-01

    Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

  13. Stellar Astrophysics with Arcus

    NASA Astrophysics Data System (ADS)

    Brickhouse, Nancy S.; Huenemoerder, David P.; Wolk, Scott; Schulz, Norbert; Foster, Adam; Brenneman, Laura; Poppenhaeger, Katja; Arcus Team

    2018-01-01

    The Arcus mission is now in Phase A of the NASA Medium-Class Explorer competition. We present here the Arcus science case for stellar astrophysics. With spectral resolving power of at least 2500 and effective area greater than 400 cm^2, Arcus will measure new diagnostic lines, e.g. for H- and He-like ions of oxygen and other elements. Weak dielectronic recombination lines will provide sensitive measurements of temperature to test stellar coronal heating models. Arcus will also resolve the coronal and accretion line components in young accreting stars, allowing detailed studies of accretion shocks and their post-shock behavior. Arcus can resolve line shapes and variability in hot star winds to study inhomogeneities and dynamics of wind structure. Such profiles will provide an independent measure of mass loss rates, for which theoretical and observational discrepancies can reach an order of magnitude. Arcus will also study exoplanet atmospheres through X-ray absorption, determing their extent and composition.

  14. Absolute Spatially- and Temporally-Resolved Optical Emission Measurements of rf Glow Discharges in Argon

    PubMed Central

    Djurović, S.; Roberts, J. R.; Sobolewski, M. A.; Olthoff, J. K.

    1993-01-01

    Spatially- and temporally-resolved measurements of optical emission intensities are presented from rf discharges in argon over a wide range of pressures (6.7 to 133 Pa) and applied rf voltages (75 to 200 V). Results of measurements of emission intensities are presented for both an atomic transition (Ar I, 750.4 nm) and an ionic transition (Ar II, 434.8 nm). The absolute scale of these optical emissions has been determined by comparison with the optical emission from a calibrated standard lamp. All measurements were made in a well-defined rf reactor. They provide detailed characterization of local time-resolved plasma conditions suitable for the comparison with results from other experiments and theoretical models. These measurements represent a new level of detail in diagnostic measurements of rf plasmas, and provide insight into the electron transport properties of rf discharges. PMID:28053464

  15. Depth-resolved fluorescence of human ectocervical tissue

    NASA Astrophysics Data System (ADS)

    Wu, Yicong; Xi, Peng; Cheung, Tak-Hong; Yim, So Fan; Yu, Mei-Yung; Qu, Jianan Y.

    2005-04-01

    The depth-resolved autofluorescence of normal and dysplastic human ectocervical tissue within 120um depth were investigated utilizing a portable confocal fluorescence spectroscopy with the excitations at 355nm and 457nm. From the topmost keratinizing layer of all ectocervical tissue samples, strong keratin fluorescence with the spectral characteristics similar to collagen was observed, which created serious interference in seeking the correlation between tissue fluorescence and tissue pathology. While from the underlying non-keratinizing epithelial layer, the measured NADH fluorescence induced by 355nm excitation and FAD fluorescence induced by 457nm excitation were strongly correlated to the tissue pathology. The ratios between NADH over FAD fluorescence increased statistically in the CIN epithelial relative to the normal and HPV epithelia, which indicated increased metabolic activity in precancerous tissue. This study demonstrates that the depth-resolved fluorescence spectroscopy can reveal fine structural information on epithelial tissue and potentially provide more accurate diagnostic information for determining tissue pathology.

  16. Trade-offs in Cervical Cancer Prevention: Balancing Benefits and Risks

    PubMed Central

    Stout, Natasha K.; Goldhaber-Fiebert, Jeremy D.; Ortendahl, Jesse D.; Goldie, Sue J.

    2009-01-01

    Background New screening and vaccination technologies will provide women with more options for cervical cancer prevention. Because the risk of cervical cancer diminishes with effective routine screening, women may wish to consider additional attributes, such as the likelihood of false-positive results and diagnostic procedures for mild abnormalities likely to resolve without intervention in their screening choices. Methods We used an empirically calibrated simulation model of cervical cancer in the United States to assess the benefits and potential risks associated with prevention strategies differing by primary screening test, triage test for abnormal results (cytologic testing, human papillomavirus [HPV] DNA test), and screening frequency. Outcomes included colposcopy referrals, cervical intraepithelial neoplasia (CIN) types 1 and 2 or 3, lifetime cancer risk, and quality-adjusted life expectancy. Results Across strategies, colposcopy referrals and diagnostic workups varied 3-fold, although diagnostic rates of CIN 2 or 3 were similar and 95% of positive screening test results were for mild abnormalities likely to resolve on their own. For a representative group of a thousand 20-year-old women undergoing triennial screening for 10 years, we expect 1038 colposcopy referrals (7 CIN 2 or 3 diagnoses) from combined cytologic and HPV DNA testing and fewer than 200 referrals (6–7 CIN 2 or 3 diagnoses) for strategies that use triage testing. Similarly, for a thousand 40-year-old women, combined cytologic and HPV DNA testing led to 489 referrals (9 CIN 2 or 3), whereas alternative strategies resulted in fewer than 150 referrals (7–8 CIN 2 or 3). Using cytologic testing followed by triage testing in younger women minimizes both diagnostic workups and positive HPV test results, whereas in older women diagnostic workups are minimized with HPV DNA testing followed by cytologic triage testing. Conclusions Clinically relevant information highlighting trade-offs among cervical cancer prevention strategies allows for inclusion of personal preferences into women’s decision making about screening and provides additional dimensions to the construction of clinical guidelines. PMID:18809815

  17. Ara h 2 and Ara 6 are the best predictors of severe peanut allergy: a double-blind placebo-controlled study.

    PubMed

    Kukkonen, A K; Pelkonen, A S; Mäkinen-Kiljunen, S; Voutilainen, H; Mäkelä, M J

    2015-10-01

    Component-resolved diagnostics offers a modern tool in peanut allergy, but studies applying consistently double-blind placebo-controlled challenges are lacking. We aimed to optimize diagnostics for moderate-to-severe peanut allergy in a birch-endemic region and to create an oral-peanut challenge with its allergen activity characterized. We performed double-blind placebo-controlled peanut challenges for a referred sample of 6- to 18-year-olds with peanut sensitization or a high suspicion of peanut allergy, including anaphylaxis. We measured specific IgE (sIgE) to Ara h 1, 2, 3, 6, 8, and 9. Testing of allergen activity of the challenge products was by IgE microarray inhibition. Of the 102 patients, 69 were challenge positive: 25 (36%) had severe, 36 (52%) moderate, and 8 (12%) mild symptoms; 38 (37%) received adrenalin. SIgE to Ara h 6 AUC 0.98 (95%CI, 0.96-1.00) was the best marker of moderate-to-severe allergy. When sIgE to Ara h 2 and Ara h 6 was measured together, all (100%) severe reactions at low doses were successfully diagnosable. SIgE to Ara h 8 had no diagnostic value, AUC 0.42 (95%CI, 0.30-0.52). Both nonroasted and roasted peanut inhibited 100% of IgE binding to Ara h 1, 2, 3, and 6. Nonroasted peanut inhibited 87% of IgE binding to Ara h 8, roasted inhibited 30%. The products lacked Ara h 9 activity. Co-sensitization to Ara h 2 and Ara h 6 was associated with severe reactions distinguishing severe allergy from mild symptoms. SIgE to Ara h 8 added no diagnostic value. Component-resolved diagnostics reduce the need for oral challenges in peanut allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Extended resolvent and inverse scattering with an application to KPI

    NASA Astrophysics Data System (ADS)

    Boiti, M.; Pempinelli, F.; Pogrebkov, A. K.; Prinari, B.

    2003-08-01

    We present in detail an extended resolvent approach for investigating linear problems associated to 2+1 dimensional integrable equations. Our presentation is based as an example on the nonstationary Schrödinger equation with potential being a perturbation of the one-soliton potential by means of a decaying two-dimensional function. Modification of the inverse scattering theory as well as properties of the Jost solutions and spectral data as follows from the resolvent approach are given.

  19. 47 CFR 95.861 - Interference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO...-219 MHz Service system, the licensees of both systems must cooperate and resolve the problem by... CTS(s) or RTU(s) causing the problem(s) must discontinue operation. (f) The boundary of the 218-219...

  20. 47 CFR 95.861 - Interference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO...-219 MHz Service system, the licensees of both systems must cooperate and resolve the problem by... CTS(s) or RTU(s) causing the problem(s) must discontinue operation. (f) The boundary of the 218-219...

  1. Problem-Based Learning

    ERIC Educational Resources Information Center

    Allen, Deborah E.; Donham, Richard S.; Bernhardt, Stephen A.

    2011-01-01

    In problem-based learning (PBL), students working in collaborative groups learn by resolving complex, realistic problems under the guidance of faculty. There is some evidence of PBL effectiveness in medical school settings where it began, and there are numerous accounts of PBL implementation in various undergraduate contexts, replete with…

  2. Why Is the Overheating Problem Difficult: the Role of Entropy

    NASA Technical Reports Server (NTRS)

    Liou, Meng-Sing

    2013-01-01

    The development of computational fluid dynamics over the last few decades has yielded enormous successes and capabilities being routinely employed today; however there remain some open problems to be properly resolved-some are fundamental in nature and some resolvable by operational changes. These two categories are distinguished and broadly explored previously. One, that belongs to the former, is the so-called overheating problem, especially in rarefying flow. This problem up to date still dogs every method known to the author; a solution to it remains elusive. The study in this paper concludes that: (1) the entropy increase is quantitatively linked to the increase in the temperature increase, (2) it is argued that the overheating is inevitable in the current shock capturing or traditional finite difference framework, and (3) a simple hybrid method is proposed that removes the overheating problem in the rarefying problems, but also retains the property of accurate shock capturing. This remedy (enhancement of current numerical methods) can be included easily in the present Eulerian codes.

  3. Studying bacteria in respiratory specimens by using conventional and molecular microbiological approaches

    PubMed Central

    Rogers, Geraint B; Daniels, Thomas WV; Tuck, Andrew; Carroll, Mary P; Connett, Gary J; David, Gondi JP; Bruce, Kenneth D

    2009-01-01

    Background Drawing from previous studies, the traditional routine diagnostic microbiology evaluation of samples from chronic respiratory conditions may provide an incomplete picture of the bacteria present in airways disease. Here, the aim was to determine the extent to which routine diagnostic microbiology gave a different assessment of the species present in sputa when analysed by using culture-independent assessment. Methods Six different media used in routine diagnostic microbiology were inoculated with sputum from twelve patients. Bacterial growth on these plates was harvested and both RNA and DNA extracted. DNA and RNA were also extracted directly from the same sample of sputum. All nucleic acids served as templates for PCR and reverse transcriptase-PCR amplification of "broad range" bacterial 16S rRNA gene regions. The regions amplified were separated by Terminal Restriction Fragment Length Polymorphism (T-RFLP) profiling and compared to assess the degree of overlap between approaches. Results A mean of 16.3 (SD 10.0) separate T-RF band lengths in the profiles from each sputum sample by Direct Molecular Analysis, with a mean of 8.8 (SD 5.8) resolved by DNA profiling and 13.3 (SD 8.0) resolved by RNA profiling. In comparison, 8.8 (SD 4.4) T-RF bands were resolved in profiles generated by Culture-derived Molecular Analysis. There were a total of 184 instances of T-RF bands detected in the direct sputum profiles but not in the corresponding culture-derived profiles, representing 83 different T-RF band lengths. Amongst these were fifteen instances where the T-RF band represented more than 10% of the total band volume (with a mean value of 23.6%). Eight different T-RF band lengths were resolved as the dominant band in profiles generated directly from sputum. Of these, only three were detected in profiles generated from the corresponding set of cultures. Conclusion Due to their focus on isolation of a small group of recognised pathogens, the use of culture-dependent methods to analyse samples from chronic respiratory infections can provide a restricted understanding of the bacterial species present. The use of a culture-independent molecular approach here identifies that there are many bacterial species in samples from CF and COPD patients that may be clinically relevant. PMID:19368727

  4. Model of critical diagnostic reasoning: achieving expert clinician performance.

    PubMed

    Harjai, Prashant Kumar; Tiwari, Ruby

    2009-01-01

    Diagnostic reasoning refers to the analytical processes used to determine patient health problems. While the education curriculum and health care system focus on training nurse clinicians to accurately recognize and rescue clinical situations, assessments of non-expert nurses have yielded less than satisfactory data on diagnostic competency. The contrast between the expert and non-expert nurse clinician raises the important question of how differences in thinking may contribute to a large divergence in accurate diagnostic reasoning. This article recognizes superior organization of one's knowledge base, using prototypes, and quick retrieval of pertinent information, using similarity recognition as two reasons for the expert's superior diagnostic performance. A model of critical diagnostic reasoning, using prototypes and similarity recognition, is proposed and elucidated using case studies. This model serves as a starting point toward bridging the gap between clinical data and accurate problem identification, verification, and management while providing a structure for a knowledge exchange between expert and non-expert clinicians.

  5. Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms.

    PubMed

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-07-01

    The use of contrast media and the time-resolved imaging of contrast kinetics (TRICKS) technique have some theoretical advantages over time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. We prospectively compared the diagnostic performance of TRICKS and TOF-MRA with digital subtracted angiography (DSA) in the assessment of occlusion of embolized aneurysms. Seventy-two consecutive patients with 72 aneurysms were examined 3 months after embolization. Test characteristics of TOF-MRA and TRICKS were calculated for the detection of residual flow. The results of quantification of flow were compared with weighted kappa. Intraobserver and interobserver reproducibility was determined. The sensitivity of TOF-MRA was 85% (95% CI, 65-96%) and of TRICKS, 89% (95% CI, 70-97%). The specificity of both methods was 91% (95% CI, 79-98%). The accuracy of the flow quantification ranged from 0.76 (TOF-MRA) to 0.83 (TRICKS). There was no significant difference between the methods in the area under the ROC curve regarding both the detection and the quantification of flow. Intraobserver reproducibility was very good with both techniques (kappa, 0.86-0.89). The interobserver reproducibility was moderate for TOF-MRA and very good for TRICKS (kappa, 0.74-0.80). In this study, TOF-MRA and TRICKS presented similar diagnostic performance; therefore, the use of time-resolved contrast-enhanced MRA is not justified in the follow-up of embolized aneurysms.

  6. Medical Care and Your 13- to 18-Year-Old

    MedlinePlus

    ... protective sports gear how to resolve conflicts without violence , including how to avoid the use of weapons learning problems or difficulties at school importance of regular physical activity Common Medical Problems ...

  7. Application of Dynamic Logic Algorithm to Inverse Scattering Problems Related to Plasma Diagnostics

    NASA Astrophysics Data System (ADS)

    Perlovsky, L.; Deming, R. W.; Sotnikov, V.

    2010-11-01

    In plasma diagnostics scattering of electromagnetic waves is widely used for identification of density and wave field perturbations. In the present work we use a powerful mathematical approach, dynamic logic (DL), to identify the spectra of scattered electromagnetic (EM) waves produced by the interaction of the incident EM wave with a Langmuir soliton in the presence of noise. The problem is especially difficult since the spectral amplitudes of the noise pattern are comparable with the amplitudes of the scattered waves. In the past DL has been applied to a number of complex problems in artificial intelligence, pattern recognition, and signal processing, resulting in revolutionary improvements. Here we demonstrate its application to plasma diagnostic problems. [4pt] Perlovsky, L.I., 2001. Neural Networks and Intellect: using model-based concepts. Oxford University Press, New York, NY.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scime, Earl E.

    The magnitude and spatial dependence of neutral density in magnetic confinement fusion experiments is a key physical parameter, particularly in the plasma edge. Modeling codes require precise measurements of the neutral density to calculate charge-exchange power losses and drag forces on rotating plasmas. However, direct measurements of the neutral density are problematic. In this work, we proposed to construct a laser-based diagnostic capable of providing spatially resolved measurements of the neutral density in the edge of plasma in the DIII-D tokamak. The diagnostic concept is based on two-photon absorption laser induced fluorescence (TALIF). By injecting two beams of 205 nmmore » light (co or counter propagating), ground state hydrogen (or deuterium or tritium) can be excited from the n = 1 level to the n = 3 level at the location where the two beams intersect. Individually, the beams experience no absorption, and therefore have no difficulty penetrating even dense plasmas. After excitation, a fraction of the hydrogen atoms decay from the n = 3 level to the n = 2 level and emit photons at 656 nm (the H α line). Calculations based on the results of previous TALIF experiments in magnetic fusion devices indicated that a laser pulse energy of approximately 3 mJ delivered in 5 ns would provide sufficient signal-to-noise for detection of the fluorescence. In collaboration with the DIII-D engineering staff and experts in plasma edge diagnostics for DIII-D from Oak Ridge National Laboratory (ORNL), WVU researchers designed a TALIF system capable of providing spatially resolved measurements of neutral deuterium densities in the DIII-D edge plasma. The laser systems were specified, purchased, and assembled at WVU. The TALIF system was tested on a low-power hydrogen discharge at WVU and the plan was to move the instrument to DIII-D for installation in collaboration with ORNL researchers. After budget cuts at DIII-D, the DIII-D facility declined to support installation on their tokamak. Instead, after a no-cost extension, the apparatus was moved to the University of Washington-Seattle and successfully tested on the HIT-SI3 spheromak experiment. As a result of this project, TALIF measurements of the absolutely calibrated neutral density hydrogen and deuterium were obtained in a helicon source and in a spheromak, designs were developed for installation of a TALIF system on a tokamak, and a new, xenon-based calibration scheme was proposed and demonstrated. The xenon-calibration scheme eliminates significant problems that were identified with the standard krypton calibration scheme.« less

  9. Sequential Test Strategies for Multiple Fault Isolation

    NASA Technical Reports Server (NTRS)

    Shakeri, M.; Pattipati, Krishna R.; Raghavan, V.; Patterson-Hine, Ann; Kell, T.

    1997-01-01

    In this paper, we consider the problem of constructing near optimal test sequencing algorithms for diagnosing multiple faults in redundant (fault-tolerant) systems. The computational complexity of solving the optimal multiple-fault isolation problem is super-exponential, that is, it is much more difficult than the single-fault isolation problem, which, by itself, is NP-hard. By employing concepts from information theory and Lagrangian relaxation, we present several static and dynamic (on-line or interactive) test sequencing algorithms for the multiple fault isolation problem that provide a trade-off between the degree of suboptimality and computational complexity. Furthermore, we present novel diagnostic strategies that generate a static diagnostic directed graph (digraph), instead of a static diagnostic tree, for multiple fault diagnosis. Using this approach, the storage complexity of the overall diagnostic strategy reduces substantially. Computational results based on real-world systems indicate that the size of a static multiple fault strategy is strictly related to the structure of the system, and that the use of an on-line multiple fault strategy can diagnose faults in systems with as many as 10,000 failure sources.

  10. Towards a conceptual multi-agent-based framework to simulate the spatial group decision-making process

    NASA Astrophysics Data System (ADS)

    Ghavami, Seyed Morsal; Taleai, Mohammad

    2017-04-01

    Most spatial problems are multi-actor, multi-issue and multi-phase in nature. In addition to their intrinsic complexity, spatial problems usually involve groups of actors from different organizational and cognitive backgrounds, all of whom participate in a social structure to resolve or reduce the complexity of a given problem. Hence, it is important to study and evaluate what different aspects influence the spatial problem resolution process. Recently, multi-agent systems consisting of groups of separate agent entities all interacting with each other have been put forward as appropriate tools to use to study and resolve such problems. In this study, then in order to generate a better level of understanding regarding the spatial problem group decision-making process, a conceptual multi-agent-based framework is used that represents and specifies all the necessary concepts and entities needed to aid group decision making, based on a simulation of the group decision-making process as well as the relationships that exist among the different concepts involved. The study uses five main influencing entities as concepts in the simulation process: spatial influence, individual-level influence, group-level influence, negotiation influence and group performance measures. Further, it explains the relationship among different concepts in a descriptive rather than explanatory manner. To illustrate the proposed framework, the approval process for an urban land use master plan in Zanjan—a provincial capital in Iran—is simulated using MAS, the results highlighting the effectiveness of applying an MAS-based framework when wishing to study the group decision-making process used to resolve spatial problems.

  11. X-ray Diffraction and Multi-Frame Phase Contrast Imaging Diagnostics for IMPULSE at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iverson, Adam; Carlson, Carl; Young, Jason

    2013-07-08

    The diagnostic needs of any dynamic loading platform present unique technical challenges that must be addressed in order to accurately measure in situ material properties in an extreme environment. The IMPULSE platform (IMPact system for Ultrafast Synchrotron Experiments) at the Advanced Photon Source (APS) is no exception and, in fact, may be more challenging, as the imaging diagnostics must be synchronized to both the experiment and the 60 ps wide x-ray bunches produced at APS. The technical challenges of time-resolved x-ray diffraction imaging and high-resolution multi-frame phase contrast imaging (PCI) are described in this paper. Example data from recent IMPULSEmore » experiments are shown to illustrate the advances and evolution of these diagnostics with a focus on comparing the performance of two intensified CCD cameras and their suitability for multi-frame PCI. The continued development of these diagnostics is fundamentally important to IMPULSE and many other loading platforms and will benefit future facilities such as the Dynamic Compression Sector at APS and MaRIE at Los Alamos National Laboratory.« less

  12. A high-speed two-frame, 1-2 ns gated X-ray CMOS imager used as a hohlraum diagnostic on the National Ignition Facility (invited).

    PubMed

    Chen, Hui; Palmer, N; Dayton, M; Carpenter, A; Schneider, M B; Bell, P M; Bradley, D K; Claus, L D; Fang, L; Hilsabeck, T; Hohenberger, M; Jones, O S; Kilkenny, J D; Kimmel, M W; Robertson, G; Rochau, G; Sanchez, M O; Stahoviak, J W; Trotter, D C; Porter, J L

    2016-11-01

    A novel x-ray imager, which takes time-resolved gated images along a single line-of-sight, has been successfully implemented at the National Ignition Facility (NIF). This Gated Laser Entrance Hole diagnostic, G-LEH, incorporates a high-speed multi-frame CMOS x-ray imager developed by Sandia National Laboratories to upgrade the existing Static X-ray Imager diagnostic at NIF. The new diagnostic is capable of capturing two laser-entrance-hole images per shot on its 1024 × 448 pixels photo-detector array, with integration times as short as 1.6 ns per frame. Since its implementation on NIF, the G-LEH diagnostic has successfully acquired images from various experimental campaigns, providing critical new information for understanding the hohlraum performance in inertial confinement fusion (ICF) experiments, such as the size of the laser entrance hole vs. time, the growth of the laser-heated gold plasma bubble, the change in brightness of inner beam spots due to time-varying cross beam energy transfer, and plasma instability growth near the hohlraum wall.

  13. Mirrors & Windows into Student Noticing

    ERIC Educational Resources Information Center

    Dominguez, Higinio

    2016-01-01

    In many classrooms, students solve problems posed by others--teachers, textbooks, and test materials. These problems typically describe a contrived situation followed by a question about an unknown that students are expected to resolve. Unsurprisingly, many students avoid reading these problems for meaning and instead engage in a suspension of…

  14. Characterizing a Hidden Group of At-Risk Drinkers: Epidemiological Profiles of Alcohol-Use Disorder Diagnostic Orphans.

    PubMed

    Gilbert, Paul A; Marzell, Miesha

    2017-11-29

    Drinkers who report some symptoms of alcohol-use disorder (AUD) but fail to meet full criteria are "diagnostic orphans." To improve risk-reduction efforts, we sought to develop better epidemiologic profiles of this underrecognized subgroup. This study estimated the population prevalence and described AUD symptoms of diagnostic orphans using the 2012-2013 National Epidemiological Survey of Alcohol and Related Conditions-III. Multivariate logistic regression was used to model odds of being a diagnostic orphan or meeting mild, moderate, and severe AUD criteria versus no AUD symptoms. Models were adjusted for the complex survey design using sampling weights and survey procedures (e.g., proc surveylogistic). Among drinkers, 14% of men and 11% of women were classified as diagnostic orphans. The most common symptoms were drinking more or for longer periods than intended, wanting or trying unsuccessfully to quit or cut back, and drinking in ways that increased risk of injury. We noted broad similarities between diagnostic orphans and mild/moderate AUD groups. There were no differences in odds of diagnostic orphans status by race/ethnicity; however, female gender was associated with lower odds of diagnostic orphan status and all levels of AUD. Individual history of AUD, family history of problem drinking, concurrent smoking, and concurrent marijuana use were associated with greater odds of problem drinking, with stronger associations as AUD severity increased. Diagnostic orphans remain a sizeable and overlooked population of problem drinkers. Clarifying the array of symptoms and cooccurring disorders can improve screening and facilitate alcohol risk-reduction intervention efforts.

  15. Terminological debate over language impairment in children: forward movement and sticking points

    PubMed Central

    Reilly, Sheena; Bishop, Dorothy V M; Tomblin, Bruce

    2014-01-01

    Background There is no agreed terminology for describing childhood language problems. In this special issue Reilly et al. and Bishop review the history of the most widely used label, ‘specific language impairment’ (SLI), and discuss the pros and cons of various terms. Commentators from a range of backgrounds, in terms of both discipline and geographical background, were then invited to respond to each lead article. Aims To summarize the main points made by the commentators and identify (1) points of consensus and disagreement, (2) issues for debate including the drivers for change and diagnostic criteria, and (3) the way forward. Conclusions & Implications There was some common ground, namely that the current situation is not tenable because it impedes clinical and research progress and impacts on access to services. There were also wide-ranging disagreements about which term should be adopted. However, before debating the broad diagnostic label it is essential to consider the diagnostic criteria and the systems used to classify childhood language problems. This is critical in order to facilitate communication between and among clinicians and researchers, across sectors (in particular health and education), with the media and policy-makers and with families and individuals who have language problems. We suggest four criteria be taken into account when establishing diagnostic criteria, including: (1) the features of language, (2) the impact on functioning and participation, (3) the presence/absence of other impairments, and (4) the language trajectory or pathway and age of onset. In future, these criteria may expand to include the genetic and neural markers for language problems. Finally, there was overarching agreement about the need for an international and multidisciplinary forum to move this debate forward. The purpose would be to develop consensus regarding the diagnostic criteria and diagnostic label for children with language problems. This process should include canvassing the views of families and people with language problems as well as the views of policy-makers. PMID:25142092

  16. Extracting 3D Information from 1D and 2D Diagnostic Systems on the DIII-D Tokamak

    NASA Astrophysics Data System (ADS)

    Brookman, Michael

    2017-10-01

    The interpretation of tokamak data often hinges on assumptions of axisymetry and flux surface equilibria, neglecting 3D effects. This work discusses examples on the DIII-D tokamak where this assumption is an insufficient approximation, and explores the diagnostic information available to resolve 3D effects while preserving 1D profiles. Methods for extracting 3D data from the electron cyclotron emission radiometers, density profile reflectometer, and Thomson scattering system are discussed. Coordinating diagnostics around the tokamak shows the significance of 3D features, such as sawteeth[1] and resonant magnetic perturbations. A consequence of imposed 3D perturbations is a shift in major radius of measured profiles between diagnostics at different toroidal locations. Integrating different diagnostics requires a database containing information about their toroidal, poloidal, and radial locations. Through the data analysis framework OMFIT, it is possible to measure the magnitude of the apparent shifts from 3D effects and enforce consistency between diagnostics. Using the existing 1D and 2D diagnostic systems on DIII-D, this process allows the effects of the 3D perturbations on 1D profiles to be addressed. Supported by US DOE contracts DE-FC02-04ER54698, DE-FG03-97ER54415.

  17. Fix and forget or fix and report: a qualitative study of tensions at the front line of incident reporting.

    PubMed

    Hewitt, Tanya Anne; Chreim, Samia

    2015-05-01

    Practitioners frequently encounter safety problems that they themselves can resolve on the spot. We ask: when faced with such a problem, do practitioners fix it in the moment and forget about it, or do they fix it in the moment and report it? We consider factors underlying these two approaches. We used a qualitative case study design employing in-depth interviews with 40 healthcare practitioners in a tertiary care hospital in Ontario, Canada. We conducted a thematic analysis, and compared the findings with the literature. 'Fixing and forgetting' was the main choice that most practitioners made in situations where they faced problems that they themselves could resolve. These situations included (A) handling near misses, which were seen as unworthy of reporting since they did not result in actual harm to the patient, (B) prioritising solving individual patients' safety problems, which were viewed as unique or one-time events and (C) encountering re-occurring safety problems, which were framed as inevitable, routine events. In only a few instances was 'fixing and reporting' mentioned as a way that the providers dealt with problems that they could resolve. We found that generally healthcare providers do not prioritise reporting if a safety problem is fixed. We argue that fixing and forgetting patient safety problems encountered may not serve patient safety as well as fixing and reporting. The latter approach aligns with recent calls for patient safety to be more preventive. We consider implications for practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Annotation: The Similarities and Differences between Autistic Disorder and Asperger's Disorder--A Review of the Empirical Evidence

    ERIC Educational Resources Information Center

    Macintosh, Kathleen E.; Dissanayake, Cheryl

    2004-01-01

    Background: The ongoing controversy over the distinction between autistic disorder and Asperger's disorder is important to resolve because of the implications regarding an understanding of the aetiology and prognosis, and the diagnostic and clinical practices relating to these conditions. This paper provides a critical evaluation of current…

  19. Input relegation control for gross motion of a kinematically redundant manipulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unseren, M.A.

    1992-10-01

    This report proposes a method for resolving the kinematic redundancy of a serial link manipulator moving in a three-dimensional workspace. The underspecified problem of solving for the joint velocities based on the classical kinematic velocity model is transformed into a well-specified problem. This is accomplished by augmenting the original model with additional equations which relate a new vector variable quantifying the redundant degrees of freedom (DOF) to the joint velocities. The resulting augmented system yields a well specified solution for the joint velocities. Methods for selecting the redundant DOF quantifying variable and the transformation matrix relating it to the jointmore » velocities are presented so as to obtain a minimum Euclidean norm solution for the joint velocities. The approach is also applied to the problem of resolving the kinematic redundancy at the acceleration level. Upon resolving the kinematic redundancy, a rigid body dynamical model governing the gross motion of the manipulator is derived. A control architecture is suggested which according to the model, decouples the Cartesian space DOF and the redundant DOF.« less

  20. Unsteady, one-dimensional gas dynamics computations using a TVD type sequential solver

    NASA Technical Reports Server (NTRS)

    Thakur, Siddharth; Shyy, Wei

    1992-01-01

    The efficacy of high resolution convection schemes to resolve sharp gradient in unsteady, 1D flows is examined using the TVD concept based on a sequential solution algorithm. Two unsteady flow problems are considered which include the problem involving the interaction of the various waves in a shock tube with closed reflecting ends and the problem involving the unsteady gas dynamics in a tube with closed ends subject to an initial pressure perturbation. It is concluded that high accuracy convection schemes in a sequential solution framework are capable of resolving discontinuities in unsteady flows involving complex gas dynamics. However, a sufficient amount of dissipation is required to suppress oscillations near discontinuities in the sequential approach, which leads to smearing of the solution profiles.

  1. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR PROBLEM MANAGEMENT (G06)

    EPA Science Inventory

    The purpose of this SOP is to describe problem management, and to define a set of reporting actions to be taken in the event of a problem during any phase of the study. This procedure outlines the steps for making a problem known in order that it may be systematically resolved b...

  2. Analysis of quaternary ammonium compounds in estuarine sediments by LC-ToF-MS: very high positive mass defects of alkylamine ions provide powerful diagnostic tools for identification and structural elucidation

    PubMed Central

    Li, Xiaolin; Brownawell, Bruce J.

    2009-01-01

    A sensitive and robust method of analysis for quaternary ammonium compounds (QACs) in marine sediments is presented. Methods for extraction, sample purification, and HPLC-Time-of-Flight-MS analysis were optimized, providing solutions to problems associated with analysis of QACs, such as dialkyldimethylammonium (DADMAC) and benzalkonium (BAC) compounds experienced previously. Recognized in this study are the exceptionally high positive mass defects characteristic of alkylammonium or protonated alkylamine ions. No alternative and chemically-viable elemental formulas exist within 25.2 mDa when the number of double bond equivalents is low, effectively allowing facile discrimination of this compound class in complex mixtures. Accurate mass measurements of diagnostic collision induced dissociation fragment ions and heavy isotope peaks were obtained and also seen to be uniquely heavy compared to other elemental formulae. In the case of BACs, the ability to resolve masses of alkylamine fragment ions is greater than it is for molecular ions, opening up a wide range of potential applications. The power of utilizing a combination of approaches is illustrated with the identification of non-targeted DADMAC C8:C8 and C8:C10, two widely used biocides previously unreported in environmental samples. Concentrations of QACs in sewage-impacted estuarine sediments (up to 74 μg/g) were higher than concentrations of other organic contaminants measured in the same or nearby samples, suggesting further study is needed. PMID:19739657

  3. Content Analysis of Student Essays after Attending a Problem-Based Learning Course: Facilitating the Development of Critical Thinking and Communication Skills in Japanese Nursing Students

    PubMed Central

    Itatani, Tomoya; Nagata, Kyoko; Yanagihara, Kiyoko; Tabuchi, Noriko

    2017-01-01

    The importance of active learning has continued to increase in Japan. The authors conducted classes for first-year students who entered the nursing program using the problem-based learning method which is a kind of active learning. Students discussed social topics in classes. The purposes of this study were to analyze the post-class essay, describe logical and critical thinking after attended a Problem-Based Learning (PBL) course. The authors used Mayring’s methodology for qualitative content analysis and text mining. In the description about the skills required to resolve social issues, seven categories were extracted: (recognition of diverse social issues), (attitudes about resolving social issues), (discerning the root cause), (multi-lateral information processing skills), (making a path to resolve issues), (processivity in dealing with issues), and (reflecting). In the description about communication, five categories were extracted: (simple statement), (robust theories), (respecting the opponent), (communication skills), and (attractive presentations). As the result of text mining, the words extracted more than 100 times included “issue,” “society,” “resolve,” “myself,” “ability,” “opinion,” and “information.” Education using PBL could be an effective means of improving skills that students described, and communication in general. Some students felt difficulty of communication resulting from characteristics of Japanese. PMID:28829362

  4. Promoting the hydrostatic conceptual change test (HCCT) with four-tier diagnostic test item

    NASA Astrophysics Data System (ADS)

    Purwanto, M. G.; Nurliani, R.; Kaniawati, I.; Samsudin, A.

    2018-05-01

    Hydrostatic Conceptual Change Test (HCCT) is a diagnostic test instrument to identify students’ conception on Hydrostatic field. It is very important to support the learning process in the classroom. Based on that point of view, the researcher decided to develop HCCT instrument test into four-tier test diagnostic items. The resolve of this research is planned as the first step of four-tier test-formatted HCCT development as one of investigative test instrument on Hydrostatic. The research method used the 4D model which has four comprehensive steps: 1) defining, 2) designing, 3) developing and 4) disseminating. The instrument developed has been tried to 30 students in one of senior high schools. The data showed that four-tier- test-formatted HCCT is able to identify student’s conception level of Hydrostatic. In conclusion, the development of four-tier test-formatted HCCT is one of potential diagnostic test instrument that able to classify the category of students who misconception, no understanding, understanding, partial understanding and no codeable about concept of Hydrostatic.

  5. Sesame allergy: current perspectives.

    PubMed

    Adatia, Adil; Clarke, Ann Elaine; Yanishevsky, Yarden; Ben-Shoshan, Moshe

    2017-01-01

    Sesame is an important global allergen affecting ~0.1% of the North American population. It is a major cause of anaphylaxis in the Middle East and is the third most common food allergen in Israel. We conducted a systematic review of original articles published in the last 10 years regarding the diagnosis and management of sesame allergy. Skin prick testing appears to be a useful predictor of sesame allergy in infants, although data are less consistent in older children and adults. The diagnostic capacity of serum-specific immunoglobulin E is poor, especially in studies that used oral food challenges to confirm the diagnosis. Double-blind, placebo-controlled food challenge thus remains the diagnostic gold standard for sesame allergy. The cornerstone of sesame allergy management is allergen avoidance, though accidental exposures are common and patients must be prepared to treat the consequent reactions with epinephrine. Novel diagnostic and treatment options such as component-resolved diagnostics, basophil activation testing, and oral immunotherapy are under development but are not ready for mainstream clinical application.

  6. Staff Grief Resolution and Care for the Elderly: Artificial Intelligence Analysis.

    ERIC Educational Resources Information Center

    Seibert, Phyllis M.; Pastorello, Thomas

    Literature on health professionals describes the problems associated with unresolved or poorly resolved grief. Previous research has indicated that the most important reason why health professionals stay in their jobs is their relationship to patients. This study examined how nursing home personnel resolve their grief following deaths of clients.…

  7. A Diagnostic Taxonomy of Adult Career Problems.

    ERIC Educational Resources Information Center

    Campbell, Robert E.; Cellini, James V.

    1981-01-01

    Developed a taxonomy for the differential diagnosis of adult career development problems. Problem categories identified were: (1) problems in career decision making; (2) problems in implementing career plans; (3) problems in organizational/institutional performance; and (4) problems in organizational/institutional adaption. (Author)

  8. Turning Muddy Problems into Clear Solutions

    ERIC Educational Resources Information Center

    Neil, Thomas C.

    1975-01-01

    Author discusses some aspects of counseling process. Makes suggestions of how to sift through maze of distractions and generalizations counselees present as problems and how to change latter into concrete statements that reflect their true nature and indicate how to resolve them. Finally, author describes strategies that help solve problems. (SE)

  9. 49 CFR 199.239 - Operator obligation to promulgate a policy on the misuse of alcohol.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... health, work, and personal life; signs and symptoms of an alcohol problem (the employee's or a coworker's); and including intervening evaluating and resolving problems associated with the misuse of alcohol including intervening when an alcohol problem is suspected, confrontation, referral to any available EAP...

  10. 49 CFR 199.239 - Operator obligation to promulgate a policy on the misuse of alcohol.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... health, work, and personal life; signs and symptoms of an alcohol problem (the employee's or a coworker's); and including intervening evaluating and resolving problems associated with the misuse of alcohol including intervening when an alcohol problem is suspected, confrontation, referral to any available EAP...

  11. 7 CFR Appendix to Subpart - Imported Fire Ant

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... or plastic containers with drain holes prior to immersion Immerse soil balls and containers, singly... determine the probable source of the problem and to ensure that the problem is resolved. If the problem is... fiberglass, glass, or plastic in such a way that IFA is physically excluded and cannot become established...

  12. CASMI: Virtual Learning Collaborative Environment for Mathematical Enrichment

    ERIC Educational Resources Information Center

    Freiman, Viktor; Manuel, Dominic; Lirette-Pitre, Nicole

    2007-01-01

    Challenging problems can make mathematics more attractive to all learners, including the gifted. Application problems that one still finds in regular textbooks often can be resolved by applying a single mathematical concept, operation, or formula. These problems do not require a higher order of thinking. They are, therefore, less cognitively and…

  13. Teaching Pronunciation in the Learner-Centered Classroom.

    ERIC Educational Resources Information Center

    Lin, Hsiang-Pao; And Others

    Specific tools and techniques to help students of English as a Second Language overcome pronunciation problems are presented. The selection of problems addressed is based on the frequency and seriousness of errors that many native Chinese-speaking learners produce. Ways to resolve various problems (e.g., missing final consonants, misplaced stress…

  14. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl; Malinowski, K.; Czarski, T.

    2016-11-15

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signalmore » include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.« less

  15. Lobar holoprosencephaly in a Miniature Schnauzer with hypodipsic hypernatremia.

    PubMed

    Sullivan, Stacey A; Harmon, Barry G; Purinton, P Thomas; Greene, Craig E; Glerum, Leigh E

    2003-12-15

    A 9-month-old male Miniature Schnauzer was examined because of a lifelong history of behavioral abnormalities, including hypodipsia. Diagnostic evaluation revealed marked hypernatremia and a single forebrain ventricle. The behavioral abnormalities did not resolve with correction of the hypernatremia, and the dog was euthanatized. At necropsy, midline forebrain structures were absent or reduced in size, and normally paired forebrain structures were incompletely separated. Findings were diagnostic for holoprosencephaly, a potentially genetic disorder and the likely cause of the hypodipsia. Similar evaluation of affected Miniature Schnauzer dogs may reveal whether holoprosencephaly routinely underlies the thirst deficiency that may be seen in dogs of this breed.

  16. Integral electrical characteristics and local plasma parameters of a RF ion thruster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masherov, P. E.; Riaby, V. A., E-mail: riaby2001@yahoo.com; Godyak, V. A.

    2016-02-15

    Comprehensive diagnostics has been carried out for a RF ion thruster based on inductively coupled plasma (ICP) source with an external flat antenna coil enhanced by ferrite core. The ICP was confined within a cylindrical chamber with low aspect ratio to minimize plasma loss to the chamber wall. Integral diagnostics of the ICP electrical parameters (RF power balance and coil current) allowed for evaluation of the antenna coils, matching networks, and eddy current loss and the true RF power deposited to plasma. Spatially resolved electron energy distribution functions, plasma density, electron temperatures, and plasma potentials were measured with movable Langmuirmore » probes.« less

  17. Imaging motional Stark effect measurements at ASDEX Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, O. P.; Burckhart, A.; McDermott, R.

    2016-11-15

    This paper presents an overview of results from the Imaging Motional Stark Effect (IMSE) diagnostic obtained during its first measurement campaign at ASDEX Upgrade since installation as a permanent diagnostic. A brief overview of the IMSE technique is given, followed by measurements of a standard H-mode discharge, which are compared to equilibrium reconstructions showing good agreement where expected. The development of special discharges for the calibration of pitch angle is reported and safety factor profile changes during sawteeth crashes are shown, which can be resolved to a few percent due to the high sensitivity at good time resolution of themore » new IMSE system.« less

  18. Next-generation sequencing for genetic testing of familial colorectal cancer syndromes.

    PubMed

    Simbolo, Michele; Mafficini, Andrea; Agostini, Marco; Pedrazzani, Corrado; Bedin, Chiara; Urso, Emanuele D; Nitti, Donato; Turri, Giona; Scardoni, Maria; Fassan, Matteo; Scarpa, Aldo

    2015-01-01

    Genetic screening in families with high risk to develop colorectal cancer (CRC) prevents incurable disease and permits personalized therapeutic and follow-up strategies. The advancement of next-generation sequencing (NGS) technologies has revolutionized the throughput of DNA sequencing. A series of 16 probands for either familial adenomatous polyposis (FAP; 8 cases) or hereditary nonpolyposis colorectal cancer (HNPCC; 8 cases) were investigated for intragenic mutations in five CRC familial syndromes-associated genes (APC, MUTYH, MLH1, MSH2, MSH6) applying both a custom multigene Ion AmpliSeq NGS panel and conventional Sanger sequencing. Fourteen pathogenic variants were detected in 13/16 FAP/HNPCC probands (81.3 %); one FAP proband presented two co-existing pathogenic variants, one in APC and one in MUTYH. Thirteen of these 14 pathogenic variants were detected by both NGS and Sanger, while one MSH2 mutation (L280FfsX3) was identified only by Sanger sequencing. This is due to a limitation of the NGS approach in resolving sequences close or within homopolymeric stretches of DNA. To evaluate the performance of our NGS custom panel we assessed its capability to resolve the DNA sequences corresponding to 2225 pathogenic variants reported in the COSMIC database for APC, MUTYH, MLH1, MSH2, MSH6. Our NGS custom panel resolves the sequences where 2108 (94.7 %) of these variants occur. The remaining 117 mutations reside inside or in close proximity to homopolymer stretches; of these 27 (1.2 %) are imprecisely identified by the software but can be resolved by visual inspection of the region, while the remaining 90 variants (4.0 %) are blind spots. In summary, our custom panel would miss 4 % (90/2225) of pathogenic variants that would need a small set of Sanger sequencing reactions to be solved. The multiplex NGS approach has the advantage of analyzing multiple genes in multiple samples simultaneously, requiring only a reduced number of Sanger sequences to resolve homopolymeric DNA regions not adequately assessed by NGS. The implementation of NGS approaches in routine diagnostics of familial CRC is cost-effective and significantly reduces diagnostic turnaround times.

  19. Modification of the Integrated Sasang Constitutional Diagnostic Model

    PubMed Central

    Nam, Jiho

    2017-01-01

    In 2012, the Korea Institute of Oriental Medicine proposed an objective and comprehensive physical diagnostic model to address quantification problems in the existing Sasang constitutional diagnostic method. However, certain issues have been raised regarding a revision of the proposed diagnostic model. In this paper, we propose various methodological approaches to address the problems of the previous diagnostic model. Firstly, more useful variables are selected in each component. Secondly, the least absolute shrinkage and selection operator is used to reduce multicollinearity without the modification of explanatory variables. Thirdly, proportions of SC types and age are considered to construct individual diagnostic models and classify the training set and the test set for reflecting the characteristics of the entire dataset. Finally, an integrated model is constructed with explanatory variables of individual diagnosis models. The proposed integrated diagnostic model significantly improves the sensitivities for both the male SY type (36.4% → 62.0%) and the female SE type (43.7% → 64.5%), which were areas of limitation of the previous integrated diagnostic model. The ideas of these new algorithms are expected to contribute not only to the scientific development of Sasang constitutional medicine in Korea but also to that of other diagnostic methods for traditional medicine. PMID:29317897

  20. Improvement of Railroad Roller Bearing Test Procedures & Development of Roller Bearing Diagnostic Techniques. Volume 2.

    DOT National Transportation Integrated Search

    1982-04-01

    A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...

  1. Screening and Diagnostic Procedure for Identification of Adult Learning Problems. 309 Demonstration Project.

    ERIC Educational Resources Information Center

    International Labour Office, Islamabad (Pakistan). Asian and Pacific Skill Development Programme.

    This screening and diagnostic procedure is intended to identify Level 1 adults with specific learning problems. The adults not meeting criteria on the assessments for visual and auditory functions should be referred to proper medical services for full evaluations. A prescriptive teaching program should be specifically designed to meet needs of…

  2. Mathematical Frameworks for Diagnostics, Prognostics and Condition Based Maintenance Problems

    DTIC Science & Technology

    2008-08-15

    REPORT Mathematical Frameworks for Diagnostics, Prognostics and Condition Based Maintenance Problems (W911NF-05-1-0426) 14. ABSTRACT 16. SECURITY ...other documentation. 12. DISTRIBUTION AVAILIBILITY STATEMENT Approved for Public Release; Distribution Unlimited 9. SPONSORING/MONITORING AGENCY NAME...parallel and distributed computing environment were researched. In support of the Condition Based Maintenance (CBM) philosophy, a theoretical framework

  3. Self-Instructional Methods of Teaching Diagnostic Problem Solving to Automotive Students. Vocational-Industrial Education Research Report.

    ERIC Educational Resources Information Center

    Finch, Curtis R.

    The objective of this study was to investigate the effects of three methods of teaching diagnostic problem-solving (troubleshooting) to automotive students. The sample consisted of 45 community college students enrolled in automotive courses. Initially, all students received a presentation on ignition principles, and the Otis Mental Ability Test…

  4. Application of a high-repetition-rate laser diagnostic system for single-cycle-resolved imaging in internal combustion engines.

    PubMed

    Hult, Johan; Richter, Mattias; Nygren, Jenny; Aldén, Marcus; Hultqvist, Anders; Christensen, Magnus; Johansson, Bengt

    2002-08-20

    High-repetition-rate laser-induced fluorescence measurements of fuel and OH concentrations in internal combustion engines are demonstrated. Series of as many as eight fluorescence images, with a temporal resolution ranging from 10 micros to 1 ms, are acquired within one engine cycle. A multiple-laser system in combination with a multiple-CCD camera is used for cycle-resolved imaging in spark-ignition, direct-injection stratified-charge, and homogeneous-charge compression-ignition engines. The recorded data reveal unique information on cycle-to-cycle variations in fuel transport and combustion. Moreover, the imaging system in combination with a scanning mirror is used to perform instantaneous three-dimensional fuel-concentration measurements.

  5. Optical spectroscopy for quantitative sensing in human pancreatic tissues

    NASA Astrophysics Data System (ADS)

    Wilson, Robert H.; Chandra, Malavika; Lloyd, William; Chen, Leng-Chun; Scheiman, James; Simeone, Diane; McKenna, Barbara; Mycek, Mary-Ann

    2011-07-01

    Pancreatic adenocarcinoma has a five-year survival rate of only 6%, largely because current diagnostic methods cannot reliably detect the disease in its early stages. Reflectance and fluorescence spectroscopies have the potential to provide quantitative, minimally-invasive means of distinguishing pancreatic adenocarcinoma from normal pancreatic tissue and chronic pancreatitis. The first collection of wavelength-resolved reflectance and fluorescence spectra and time-resolved fluorescence decay curves from human pancreatic tissues was acquired with clinically-compatible instrumentation. Mathematical models of reflectance and fluorescence extracted parameters related to tissue morphology and biochemistry that were statistically significant for distinguishing between pancreatic tissue types. These results suggest that optical spectroscopy has the potential to detect pancreatic disease in a clinical setting.

  6. [Headhache secondary to intracranial hypotension in a Lumbar Spinal Stenosis Surgery].

    PubMed

    Hidalgo-Mendía, Begoña; Angulo-Tabernero, Marina; Jaroid-Audes, Ricardo; Untoria-Agustín, Carmen; Rivero-Zelada, David

    2016-01-01

    Intracraneal hypotension headache is a well known syndrome in neurosurgery practice. In most cases cerebrospinal fluid leaks are caused by medical interventions, such as lumbar puncture, peridural anesthesia and surgical interventions on the spine. Clinical symptoms tipically show orthostatic headache that resolves in supine position, and other symptoms like neck tightness, vertigo and diplopia. RMI diagnostic confirms paquimeningeal enhancement and subdural hygromas. Conservative treatment usually includes bed resting, hydratation and administration of caffeine or glucocorticoids, resolving spontaneously in one to four months. The importance of the diagnosis lies in the differential diagnosis with other causes of headache, as symptomatic limiting factor in the rehabilitation of the patient and the same favorable prognosis.

  7. Development of a dual-modal tissue diagnostic system combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy.

    PubMed

    Sun, Yang; Park, Jesung; Stephens, Douglas N; Jo, Javier A; Sun, Lei; Cannata, Jonathan M; Saroufeem, Ramez M G; Shung, K Kirk; Marcu, Laura

    2009-06-01

    We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical fiber-based time-domain apparatus including a spectrometer, gated multichannel plate photomultiplier, and fast digitizer. It records the fluorescence with high sensitivity (nM concentration range) and time resolution as low as 300 ps. The UBM system consists of a transducer, pulser, receiving circuit, and positioning stage. The transducer used here is 45 MHz, unfocused, with axial and lateral resolutions 38 and 200 microm. Validation of the hybrid system and ultrasonic and spectroscopic data coregistration were conducted both in vitro (tissue phantom) and ex vivo (atherosclerotic tissue specimens of human aorta). Standard histopathological analysis of tissue samples was used to validate the UBM-TRLIFS data. Current results have demonstrated that spatially correlated UBM and TR-LIFS data provide complementary characterization of both morphology (necrotic core and calcium deposits) and biochemistry (collagen, elastin, and lipid features) of the atherosclerotic plaques at the same location. Thus, a combination of fluorescence spectroscopy with ultrasound imaging would allow for better identification of features associated with tissue pathologies. Current design and performance of the hybrid system suggests potential applications in clinical diagnosis of atherosclerotic plaque.

  8. Development of a dual-modal tissue diagnostic system combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy

    PubMed Central

    Sun, Yang; Park, Jesung; Stephens, Douglas N.; Jo, Javier A.; Sun, Lei; Cannata, Jonathan M.; Saroufeem, Ramez M. G.; Shung, K. Kirk; Marcu, Laura

    2009-01-01

    We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical fiber-based time-domain apparatus including a spectrometer, gated multichannel plate photomultiplier, and fast digitizer. It records the fluorescence with high sensitivity (nM concentration range) and time resolution as low as 300 ps. The UBM system consists of a transducer, pulser, receiving circuit, and positioning stage. The transducer used here is 45 MHz, unfocused, with axial and lateral resolutions 38 and 200 μm. Validation of the hybrid system and ultrasonic and spectroscopic data coregistration were conducted both in vitro (tissue phantom) and ex vivo (atherosclerotic tissue specimens of human aorta). Standard histopathological analysis of tissue samples was used to validate the UBM-TRLIFS data. Current results have demonstrated that spatially correlated UBM and TR-LIFS data provide complementary characterization of both morphology (necrotic core and calcium deposits) and biochemistry (collagen, elastin, and lipid features) of the atherosclerotic plaques at the same location. Thus, a combination of fluorescence spectroscopy with ultrasound imaging would allow for better identification of features associated with tissue pathologies. Current design and performance of the hybrid system suggests potential applications in clinical diagnosis of atherosclerotic plaque. PMID:19566223

  9. Development of a dual-modal tissue diagnostic system combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy

    NASA Astrophysics Data System (ADS)

    Sun, Yang; Park, Jesung; Stephens, Douglas N.; Jo, Javier A.; Sun, Lei; Cannata, Jonathan M.; Saroufeem, Ramez M. G.; Shung, K. Kirk; Marcu, Laura

    2009-06-01

    We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical fiber-based time-domain apparatus including a spectrometer, gated multichannel plate photomultiplier, and fast digitizer. It records the fluorescence with high sensitivity (nM concentration range) and time resolution as low as 300 ps. The UBM system consists of a transducer, pulser, receiving circuit, and positioning stage. The transducer used here is 45 MHz, unfocused, with axial and lateral resolutions 38 and 200 μm. Validation of the hybrid system and ultrasonic and spectroscopic data coregistration were conducted both in vitro (tissue phantom) and ex vivo (atherosclerotic tissue specimens of human aorta). Standard histopathological analysis of tissue samples was used to validate the UBM-TRLIFS data. Current results have demonstrated that spatially correlated UBM and TR-LIFS data provide complementary characterization of both morphology (necrotic core and calcium deposits) and biochemistry (collagen, elastin, and lipid features) of the atherosclerotic plaques at the same location. Thus, a combination of fluorescence spectroscopy with ultrasound imaging would allow for better identification of features associated with tissue pathologies. Current design and performance of the hybrid system suggests potential applications in clinical diagnosis of atherosclerotic plaque.

  10. New portable instrument for combined reflectance, time-resolved and steady-state luminescence measurements on works of art

    NASA Astrophysics Data System (ADS)

    Romani, Aldo; Grazia, Chiara; Anselmi, Chiara; Miliani, Costanza; Brunetti, Brunetto Giovanni

    2011-06-01

    In this paper a new compact and portable instrument for combined reflectance, time-resolved and steady-state fluorescence is presented. All the optical parts of the apparatus, carefully described in the text, were chosen after an extensive market survey in order to obtain the best performances coupled with the smallest dimensions. This instrument through the use of a dedicated multiple fiber optic probe, allows the complete photophysical behaviors of investigated materials to be collected from the same point of the analyzed surface. In this way, the resultant instrumental setup is a portable device, usable in situ for non destructive and non invasive diagnostic purposes in the field of cultural heritage. Preliminary results concerning organic dyes characterization, which is the main application of luminescence-based diagnostic techniques in artworks, are presented and compared with those previously obtained using separate devices. Concerning reflectance data, improvements in the deep detectable UV spectral range have been achieved switching from the integrating sphere of the old instrument to bifurcated optical fibers used as probe in the new one. Special attention was devoted to test the instrument capability in order to obtain the true emission spectrum, corrected for the selfabsorption effect, for which good results were found. This particular experimental procedure is strongly recommended, by a diagnostic point of view, to avoid distortions in the instrumental responses, namely the spectral shape and emission maximum wavelength of a fluorophore as function of the color saturation.

  11. On the Detectability of Oxygen X-Ray Fluorescence and Its Use as a Solar Photospheric Abundance Diagnostic

    NASA Astrophysics Data System (ADS)

    Drake, Jeremy J.; Ercolano, Barbara

    2008-08-01

    Monte Carlo calculations of the O Kα line fluoresced by coronal X-rays and emitted just above the temperature minimum region of the solar atmosphere have been employed to investigate the use of this feature as an abundance diagnostic. While they are quite weak, we estimate line equivalent widths in the range 0.02-0.2 Å, depending on the X-ray plasma temperature. The line remains essentially uncontaminated by blends for coronal temperatures T <= 3 × 106 K and should be quite observable, with a flux gtrsim2 photons s-1 arcmin-2. Model calculations for solar chemical mixtures with an O abundance adjusted up and down by a factor of 2 indicate 35%-60% changes in O Kα line equivalent width, providing a potentially useful O abundance diagnostic. Sensitivity of equivalent width to differences between recently recommended chemical compositions with "high" and "low" complements of the CNO trio important for interpreting helioseismological observations is less acute, amounting to 20%-26% at coronal temperatures T <= 2 × 106 K. While still feasible for discriminating between these two mixtures, uncertainties in measured line equivalent widths and in the models used for interpretation would need to be significantly less than 20%. Provided a sensitive X-ray spectrometer with resolving power >=1000 and suitably well-behaved instrumental profile can be built, X-ray fluorescence presents a viable means for resolving the solar "oxygen crisis."

  12. Teleconsultation in paediatric orthopaedics in Djibouti: evaluation of response performance.

    PubMed

    Bertani, A; Launay, F; Candoni, P; Mathieu, L; Rongieras, F; Chauvin, F

    2012-11-01

    Djibouti has no paediatric orthopaedics department and three options are available for difficult cases: transfer of the patient to another country; overseas mission transfer to Djibouti by a specialised surgical team; and management by a local orthopaedic surgeon receiving guidance from an expert. The extreme poverty of part of the population of Djibouti often precludes the first two options. Telemedecine can allow the local orthopaedic surgeon to receive expert advice. HYPOTHESES AND STUDY DESIGN: We prospectively recorded all the paediatric orthopaedics teleconsultations that occurred between November 2009 and November 2011. Our objective was to assess the performance of the teleconsultations. We hypothetized that this option was influential in decision making. We assessed the influence of the teleconsultation on patient management (i.e., change in the surgical indication and/or procedure). We then used the electronic patient records to compare the actual management to that recommended retrospectively by two independent orthopaedic surgeon consultants who had experience working overseas. Finally, we assessed the clinical outcomes in the patients. Of 48 teleconsultations for 39 patients, 13 dealt with diagnostic problems and 35 with therapeutic problems. The teleconsultation resolved the diagnostic uncertainties in 90% of cases. Advice from the expert modified the management in 37 (77%) teleconsultations; the change was related to the surgical indication in 18 cases, the surgical technique in 13 cases, and both in six cases. Agreement between the advice from the independent consultants and the treatment delivered by the local surgeon was 2.2/3. Clinical outcomes were good or very good in 31 (81%) of the 38 treated patients. This study establishes the feasibility and usefulness of paediatric orthopaedics teleconsultations in Djibouti. The introduction of telemedicine has changed our approach to challenges raised by patients in remote locations or precarious situations. Input from experts considerably benefits patient management. III, prospective comparative study. Copyright © 2012. Published by Elsevier Masson SAS.

  13. Development of a scale to measure problem use of short message service: the SMS Problem Use Diagnostic Questionnaire.

    PubMed

    Rutland, J Brian; Sheets, Tilman; Young, Tony

    2007-12-01

    This exploratory study examines a subset of mobile phone use, the compulsive use of short message service (SMS) text messaging. A measure of SMS use, the SMS Problem Use Diagnostic Questionnaire (SMS-PUDQ), was developed and found to possess acceptable reliability and validity when compared to other measures such as self-reports of time spent using SMS and scores on a survey of problem mobile phone use. Implications for the field of addiction research, technological and behavioral addictions in particular, are discussed, and directions for future research are suggested.

  14. Resolving Rapid Variation in Energy for Particle Transport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haut, Terry Scot; Ahrens, Cory Douglas; Jonko, Alexandra

    2016-08-23

    Resolving the rapid variation in energy in neutron and thermal radiation transport is needed for the predictive simulation capability in high-energy density physics applications. Energy variation is difficult to resolve due to rapid variations in cross sections and opacities caused by quantized energy levels in the nuclei and electron clouds. In recent work, we have developed a new technique to simultaneously capture slow and rapid variations in the opacities and the solution using homogenization theory, which is similar to multiband (MB) and to the finite-element with discontiguous support (FEDS) method, but does not require closure information. We demonstrated the accuracymore » and efficiency of the method for a variety of problems. We are researching how to extend the method to problems with multiple materials and the same material but with different temperatures and densities. In this highlight, we briefly describe homogenization theory and some results.« less

  15. Social Problem Solving as a Predictor of Well-Being in Adolescents and Young Adults

    ERIC Educational Resources Information Center

    Siu, Andrew M. H.; Shek, Daniel T. L.

    2010-01-01

    Social problem solving is the cognitive-affective-behavioral process by which people attempt to resolve real-life problems in a social environment, and is of key importance in the management of emotions and well-being. This paper reviews a series of studies on social problem solving conducted by the authors. First, we developed and validated the…

  16. Kleinberg Complex Networks

    DTIC Science & Technology

    2014-10-21

    linear combinations of paths. This project featured research on two classes of routing problems , namely traveling salesman problems and multicommodity...flows. One highlight of this research was our discovery of a polynomial-time algorithm for the metric traveling salesman s-t path problem whose...metric TSP would resolve one of the most venerable open problems in the theory of approximation algorithms. Our research on traveling salesman

  17. Cognitive Delay and Behavior Problems Prior to School Age

    PubMed Central

    Palta, Mari; Kotelchuck, Milton; Poehlmann, Julie; Witt, Whitney P.

    2014-01-01

    OBJECTIVE: To investigate the relationship between cognitive delay (CD) and behavior problems between ages 9 months and 5 years, while adjusting for covariates related to CD. METHODS: Data were from 4 waves of the Early Childhood Longitudinal Study, Birth Cohort (n = 8000). Children were classified as typically developing (TD) or as having resolved, newly developed, or persistent CD between 9 and 24 months, based on scores from the Bayley Short Form-Research Edition below or above the 10th percentile. Child behavior was measured by using the Infant/Toddler Symptom Checklist (ages 9 and 24 months) and the Preschool and Kindergarten Behavior Scales (ages 4 and 5 years); children in the top 10th percentile were considered to have a behavior problem. Hierarchical linear modeling estimated the effect of CD status on children’s behavioral trajectories, adjusted for confounders. RESULTS: CD resolved for 80.3% of children between 9 and 24 months. Behavior problems at 24 months were detected in 19.3%, 21.8%, and 35.5% of children with resolved, newly developed, and persistent CD, respectively, versus 13.0% of TD children. Behavior problems increased among children with CD over time, and more so among children with persistent CD. By age 5, children with persistent CD had behavior scores moderately (0.59 SD) higher than TD children. CONCLUSIONS: Behavior problems among children with CD are slightly higher at 9 months, clearly evident by 24 months, and increase as children move toward school age. Efforts to promote the earliest identification, evaluation, and service referral may be necessary to improve outcomes for these children. PMID:25113290

  18. New classification of epilepsy-related neoplasms: The clinical perspective.

    PubMed

    Kasper, Burkhard S; Kasper, Ekkehard M

    2017-02-01

    Neoplastic CNS lesions are a common cause of focal epilepsy refractory to anticonvulsant treatment, i.e. long-term epilepsy-associated tumors (LEATs). Epileptogenic tumors encompass a variety of intriguing lesions, e.g. dysembryoplastic neuroepithelial tumors or gangliogliomas, which differ from more common CNS neoplasms in their clinical context as well as on histopathology. Long-term epilepsy-associated tumor classification is a rapidly evolving issue in surgical neuropathology, with new entities still being elucidated. One major issue to be resolved is the inconsistent tissue criteria applied to LEAT accounting for high diagnostic variability between individual centers and studies, a problem recently leading to a proposal for a new histopathological classification by Blümcke et al. in Acta Neuropathol. 2014; 128: 39-54. While a new approach to tissue diagnosis is appreciated and needed, histomorphological criteria alone will not suffice and we here approach the situation of encountering a neoplastic lesion in an epilepsy patient from a clinical perspective. Clinical scenarios to be supported by an advanced LEAT classification will be illustrated and discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The Development of a "Neighborhood in Solidarity" in Switzerland.

    PubMed

    Zwygart, Marion; Plattet, Alain; Ammor, Sarah

    2017-01-01

    This article presents a case study based on the "Neighborhood in Solidarity" (NS) methodology to illustrate its application in a locality of 8,000 inhabitants in Switzerland. This specific project is proposed to exemplify the global aim of the NS methodology. That aim is to increase the integration of elderly persons in societies in order to improve their quality of life. The case study demonstrates the enhancement of the capacity of the older people to remain actively engaged in their neighborhood. The article focuses on the creation of an autonomous community of empowered older people who can resolve their own problems after a 5-year project. The construction of the local community is presented throughout the six steps of the methodology: (1) preliminary analysis, (2) diagnostic, (3) construction, (4) project design, (5) project implementation, and (6) empowerment and with three degrees of involvement (community, participative, and integrative involvement). Performance and output indicators, quality indicators, and social determinants of health assess the development of the local project. The impacts of the projects which are illustrated in this specific example motivated this publication to inspire practitioners from other countries.

  20. The next organizational challenge: finding and addressing diagnostic error.

    PubMed

    Graber, Mark L; Trowbridge, Robert; Myers, Jennifer S; Umscheid, Craig A; Strull, William; Kanter, Michael H

    2014-03-01

    Although health care organizations (HCOs) are intensely focused on improving the safety of health care, efforts to date have almost exclusively targeted treatment-related issues. The literature confirms that the approaches HCOs use to identify adverse medical events are not effective in finding diagnostic errors, so the initial challenge is to identify cases of diagnostic error. WHY HEALTH CARE ORGANIZATIONS NEED TO GET INVOLVED: HCOs are preoccupied with many quality- and safety-related operational and clinical issues, including performance measures. The case for paying attention to diagnostic errors, however, is based on the following four points: (1) diagnostic errors are common and harmful, (2) high-quality health care requires high-quality diagnosis, (3) diagnostic errors are costly, and (4) HCOs are well positioned to lead the way in reducing diagnostic error. FINDING DIAGNOSTIC ERRORS: Current approaches to identifying diagnostic errors, such as occurrence screens, incident reports, autopsy, and peer review, were not designed to detect diagnostic issues (or problems of omission in general) and/or rely on voluntary reporting. The realization that the existing tools are inadequate has spurred efforts to identify novel tools that could be used to discover diagnostic errors or breakdowns in the diagnostic process that are associated with errors. New approaches--Maine Medical Center's case-finding of diagnostic errors by facilitating direct reports from physicians and Kaiser Permanente's electronic health record--based reports that detect process breakdowns in the followup of abnormal findings--are described in case studies. By raising awareness and implementing targeted programs that address diagnostic error, HCOs may begin to play an important role in addressing the problem of diagnostic error.

  1. Effect of Creative Drama-Based Group Guidance on Male-Adolescents' Conflict Resolution Skills

    ERIC Educational Resources Information Center

    Yavuzer, Yasemin

    2012-01-01

    Problem Statement: This study assumes that conflict itself is not constructive or destructive, whereas the path chosen to resolve the conflict is what leads to constructive or destructive results. When individuals resolve conflicts in a destructive manner, they instill feelings of anger, rage, hostility and violence in the people involved. On the…

  2. Gender Differences in the Management of Four Different Personnel Disputes with Male and Female Employees.

    ERIC Educational Resources Information Center

    Rossi, Ana; Todd-Mancillas, Wm. R.

    A study compared male and female managers' preferences for using communication-based as opposed to power-centered strategies for resolving employer-employee disputes. Subjects, 40 male and 40 female middle and upper level managers, were interviewed and asked to report their preferred manner of resolving four different personnel problems: (1) an…

  3. [Distressful journey for the metabolic syndrome to its position in clinical practice].

    PubMed

    Rybka, J

    2010-07-01

    MS is a major atherogenic syndrome in our population. The concept of MS has had a very positive effect on our knowledge of the most serious civilization diseases, the genotypic constellation of MS, although monogenic defects explain only a very small part of pathological defects. It is certain, however, that a crucial role played is by interactions between genetic factors and risk factors of external environment. Undoubtedly, insulin resistance, central obesity and impaired metabolism of adipose tissue play an important role in the pathogenesis of MS, and there are other pathogenetic theories. The author discusses briefly the history of MS and presents the best-known definitions starting with the 90s ofthe last century, ADA and EASD reservations towards MS, as well as the new harmonized definition from 2009. This modified definition ofMS has been adopted in practice in the Czech Republic due to the Czech Institute ofmetabolic syndrome. The author discusses in greater detail the WHO expert report from 2010, which indicates some limitations of diagnostic criteria for MS. Despite all the objections the expert report provides reasons to support the use of the term metabolic syndrome, and metabolic syndrome is considered to be a recognized concept that focuses attention on the importance of comprehensive, multifactorial health problems. Finally, the author mentions sub-problems related to MS, which will have to be resolved in collaboration with diabetologists.

  4. Seeking salience in engaging art: A short story about attention, artistic value, and neuroscience.

    PubMed

    Seeley, William P

    2018-01-01

    It has recently been suggested that research in neuroscience of art has failed to bring art into focus in the laboratory. Two general arguments are brought to bear in the regard. The common perceptual mechanisms argument observes that neuroscientists working within this field develop models to explain art relative to the ways that artworks are fine-tuned to the operations of perceptual systems. However, these perceptual explanations apply equally to how viewers come to recognize and understand art and nonart objects and events. Therefore these explanations fail to disambiguate artworks from other things. They fail to locate art. This observation points to a deeper problem. What interests us in art is how what we perceive has been used to show us what the work represents. Our understanding of art is governed by a range of productive and evaluative normative conventions that govern how we ought to look at a work and evaluate how it was made. The normative dimension of appreciation argument suggests that these aspects of our engagement with artworks lie outside the scope of neuroscientific explanations of art. This chapter provides a sketch of a diagnostic recognition framework for engaging art that resolves both problems and helps explains how artworks function within the social institution of the artworld to facilitate a communicative exchange between artists and consumers. © 2018 Elsevier B.V. All rights reserved.

  5. Reliability and Validity of a Procedure To Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    Preliminary psychometric data assessing the reliability and validity of a method used to measure the diagnostic reasoning and problem-solving skills of predoctoral students in orthodontia are described. The measurement approach consisted of sets of patient demographic data and dental photos and x-rays, accompanied by a set of 33 multiple-choice…

  6. Diagnostic Performance of the CBCL-Attention Problem Scale as a Screening Measure in a Sample of Brazilian Children with ADHD

    ERIC Educational Resources Information Center

    Lampert, T. L.; Polanczyk, G.; Tramontina, S.; Mardini, V.; Rohde, L. A.

    2004-01-01

    Objective: To evaluate the diagnostic performance of the Attention Problem Scale of the Child Behavior Checklist (CBCL-APS) for the screening of Attention-Deficit/Hyperactivity Disorder (ADHD) in a sample of Brazilian children and adolescents. Methods: The CBCL-APS was given to 763 children and adolescents. Child psychiatrists using DSM-IV…

  7. ENVIRONMENTAL ISOTOPES FOR RESOLUTION OF HYDROLOGY PROBLEMS

    EPA Science Inventory

    The use of environmental isotopes as tracers in the hydrosphere is increasing as analytical instrumentation improves and more applications are discovered. There exists still misconceptions on the role of isotopes in resolving hydrology problems. Naturally occurring isotopes in th...

  8. Legal Problems of Religious and Private Schools. Fourth Edition. Monograph Series, No. 65.

    ERIC Educational Resources Information Center

    Mawdsley, Ralph D.

    This book addresses the legal problems faced by nonpublic schools. It is intended to help teachers and administrators recognize potential legal difficulties and to assist educators in developing preventive strategies to resolve problems before the legal system becomes involved. The text is divided into six chapters: (1) "Tort Liability";…

  9. Unifying Approach to Analytical Chemistry and Chemical Analysis: Problem-Oriented Role of Chemical Analysis.

    ERIC Educational Resources Information Center

    Pardue, Harry L.; Woo, Jannie

    1984-01-01

    Proposes an approach to teaching analytical chemistry and chemical analysis in which a problem to be resolved is the focus of a course. Indicates that this problem-oriented approach is intended to complement detailed discussions of fundamental and applied aspects of chemical determinations and not replace such discussions. (JN)

  10. 76 FR 48207 - Federal Implementation Plans: Interstate Transport of Fine Particulate Matter and Ozone and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-08

    ... Problems and NAAQS Addressed 1. Air Quality Problems and NAAQS Addressed 2. FIP Authority for Each State... resolve nonattainment or maintenance problems at downwind state receptors. Downwind states also have... are fossil fuel-fired boilers and turbines producing electricity for sale, as detailed in section VII...

  11. 75 FR 54588 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-08

    ... notification. Copies of the submission(s) may be obtained by calling (202) 720-8681. An agency may not conduct... financial or other problems and may be initiated by either a recipient which recognizes that a problem exists and wished to resolve it, or by the Agency. If a problem exists, a recipient must furnish...

  12. 7 CFR 301.81-10 - Costs and charges.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... not remove burlap wrap or plastic containers with drain holes prior to immersion Immerse soil balls... determine the probable source of the problem and to ensure that the problem is resolved. If the problem is... fiberglass, glass, or plastic in such a way that IFA is physically excluded and cannot become established...

  13. Coinfection of Fusobacterium nucleatum and Actinomyces israelii in Mastoiditis Diagnosed by Next-Generation DNA Sequencing

    PubMed Central

    Hoogestraat, Daniel R.; Abbott, April N.; SenGupta, Dhruba J.; Cummings, Lisa A.; Butler-Wu, Susan M.; Stephens, Karen; Cookson, Brad T.; Hoffman, Noah G.

    2014-01-01

    Some bacterial infections involve potentially complex mixtures of species that can now be distinguished using next-generation DNA sequencing. We present a case of mastoiditis where Gram stain, culture, and molecular diagnosis were nondiagnostic or discrepant. Next-generation sequencing implicated coinfection of Fusobacterium nucleatum and Actinomyces israelii, resolving these diagnostic discrepancies. PMID:24574281

  14. Temperature and Electron Density Determination on Laser-Induced Breakdown Spectroscopy (LIBS) Plasmas: A Physical Chemistry Experiment

    ERIC Educational Resources Information Center

    Najarian, Maya L.; Chinni, Rosemarie C.

    2013-01-01

    This laboratory is designed for physical chemistry students to gain experience using laser-induced breakdown spectroscopy (LIBS) in understanding plasma diagnostics. LIBS uses a high-powered laser that is focused on the sample causing a plasma to form. The emission of this plasma is then spectrally resolved and detected. Temperature and electron…

  15. Hypothenar hammer syndrome and basilic bypass.

    PubMed

    Chander, R K; Phair, J; Oza, P; Patel, M; Balar, N

    2014-12-01

    We report a case of hypothenar hammer syndrome. The case presents necessary diagnostic measures and discusses the etiology of this syndrome. Additionally, the case reviews treatments, which culminated in the eventual use of ulnar artery bypass with autogenous basilica vein to treat and resolve the ischemic fingers of the patient. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. The usefulness of optical analyses for detecting vulnerable plaques using rabbit models

    NASA Astrophysics Data System (ADS)

    Nakai, Kanji; Ishihara, Miya; Kawauchi, Satoko; Shiomi, Masashi; Kikuchi, Makoto; Kaji, Tatsumi

    2011-03-01

    Purpose: Carotid artery stenting (CAS) has become a widely used option for treatment of carotid stenosis. Although technical improvements have led to a decrease in complications related to CAS, distal embolism continues to be a problem. The purpose of this research was to investigate the usefulness of optical methods (Time-Resolved Laser- Induced Fluorescence Spectroscopy [TR-LIFS] and reflection spectroscopy [RS] as diagnostic tools for assessment of vulnerable atherosclerotic lesions, using rabbit models of vulnerable plaque. Materials & Methods: Male Japanese white rabbits were divided into a high cholesterol diet group and a normal diet group. In addition, we used a Watanabe heritable hyperlipidemic (WHHL) rabbit, because we confirmed the reliability of our animal model for this study. Experiment 1: TR-LIFS. Fluorescence was induced using the third harmonic wave of a Q switch Nd:YAG laser. The TR-LIFS was performed using a photonic multi-channel analyzer with ICCD (wavelength range, 200 - 860 nm). Experiment 2: RS. Refection spectra in the wavelength range of 900 to 1700 nm were acquired using a spectrometer. Results: In the TR-LIFS, the wavelength at the peak was longer by plaque formation. The TR-LIFS method revealed a difference in peak levels between a normal aorta and a lipid-rich aorta. The RS method showed increased absorption from 1450 to 1500 nm for lipid-rich plaques. We observed absorption around 1200 nm due to lipid only in the WHHL group. Conclusion: These methods using optical analysis might be useful for diagnosis of vulnerable plaques. Keywords: Carotid artery stenting, vulnerable plaque, Time-Resolved Laser-Induced Fluorescence

  17. Design and operation of the pellet charge exchange diagnostic for measurement of energetic confined alphas and tritons on TFTR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Medley, S.S.; Duong, H.H.; Fisher, R.K.

    1996-05-01

    Radially-resolved energy and density distributions of the energetic confined alpha particles in D-T experiments on TFTR are being measured by active neutral particle analysis using low-Z impurity pellet injection. When injected into a high temperature plasma, an impurity pellet (e.g. Lithium or Boron) rapidly ablates forming an elongated cloud which is aligned with the magnetic field and moves with the pellet. This ablation cloud provides a dense target with which the alpha particles produced in D-T fusion reactions can charge exchange. A small fraction of the alpha particles incident on the pellet ablation cloud will be converted to helium neutralsmore » whose energy is essentially unchanged by the charge transfer process. By measuring the resultant helium neutrals escaping from the plasma using a mass and energy resolving charge exchange analyzer, this technique offers a direct measurement of the energy distribution of the incident high-energy alpha particles. Other energetic ion species can be detected as well, such as tritons generated in D-D plasmas and H or He{sup 3} RF-driven minority ion tails. The diagnostic technique and its application on TFTR are described in detail.« less

  18. Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

    NASA Technical Reports Server (NTRS)

    Degroot, Wilhelmus A.; Zupanc, Frank J.

    1993-01-01

    Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

  19. Portable, battery-operated, fluorescence field microscope for the developing world

    NASA Astrophysics Data System (ADS)

    Miller, Andrew R.; Davis, Gregory; Pierce, Mark; Oden, Z. Maria; Richards-Kortum, Rebecca

    2010-02-01

    In many areas of the world, current methods for diagnosis of infectious diseases such as malaria and tuberculosis involve microscopic evaluation of a patient specimen. Advances in fluorescence microscopy can improve diagnostic sensitivity and reduce time and expertise necessary to interpret diagnostic results. However, modern research-grade microscopes are neither available nor appropriate for use in many settings in the developing world. To address this need, we designed, fabricated, and tested a portable, battery-powered, bright field and fluorescence inverted field microscope, optimized for infrastructural constraints of the developing world. We characterized an initial prototype constructed with rapidprototyping techniques, which utilized low-cost, over-the-counter components such as a battery-powered LED flashlight as the light source. The microscope exhibited suitable spatial resolution (0.8 μm) in fluorescence mode to resolve M. tuberculosis bacilli. In bright field mode, malaria parasites were resolvable at 1000x magnification. The initial prototype cost 480 USD and we estimate that the microscope can be manufactured for 230 USD. While future studies are planned to evaluate ease-of-use and reliability, our current system serves as a proof of concept that combined fluorescence and bright field microscopy is possible in a low-cost and portable system.

  20. Cervical external immobilization devices: evaluation of magnetic resonance imaging issues at 3.0 Tesla.

    PubMed

    Diaz, Francis L; Tweardy, Lisa; Shellock, Frank G

    2010-02-15

    Laboratory investigation, ex vivo. Currently, no studies have addressed the magnetic resonance imaging (MRI) issues for cervical external immobilization devices at 3-Tesla. Under certain conditions significant heating may occur, resulting in patient burns. Furthermore, artifacts can be substantial and prevent the diagnostic use of MRI. Therefore, the objective of this investigation was to evaluate MRI issues for 4 different cervical external immobilization devices at 3-Tesla. Excessive heating and substantial artifacts are 2 potential complications associated with performing MRI at 3-Tesla in patients with cervical external immobilization devices. Using ex vivo testing techniques, MRI-related heating and artifacts were evaluated for 4 different cervical devices during MRI at 3-Tesla. Four cervical external immobilization devices (Generation 80, Resolve Ring and Superstructure, Resolve Ring and Jerome Vest/Jerome Superstructure, and the V1 Halo System; Ossur Americas, Aliso Viejo, CA) underwent MRI testing at 3-Tesla. All devices were made from nonmetallic or nonmagnetic materials. Heating was determined using a gelled-saline-filled skull phantom with fluoroptic thermometry probes attached to the skull pins. MRI was performed at 3-Tesla, using a high level of RF energy. Artifacts were assessed at 3-Tesla, using standard cervical imaging techniques. The Generation 80 and V1 Halo devices exhibited substantial temperature rises (11.6 degrees C and 8.5 degrees C, respectively), with "sparking" evident for the Generation 80 during the MRI procedure. Artifacts were problematic for these devices, as well. By comparison, the 2 Resolve Ring-based cervical external immobilization devices showed little or no heating (< or = 0.6 degrees C) and the artifacts were acceptable for diagnostic MRI examinations. The low degree of heating and minor artifacts associated with the Resolve-based cervical external immobilization devices indicated that these products are safe for patients undergoing MRI at 3-Tesla.

  1. Diagnostic reasoning by hospital pharmacists: assessment of attitudes, knowledge, and skills.

    PubMed

    Chernushkin, Kseniya; Loewen, Peter; de Lemos, Jane; Aulakh, Amneet; Jung, Joanne; Dahri, Karen

    2012-07-01

    Hospital pharmacists participate in activities that may be considered diagnostic. Two reasoning approaches to diagnosis have been described: non-analytic and analytic. Of the 6 analytic traditions, the probabilistic tradition has been shown to improve diagnostic accuracy and reduce unnecessary testing. To the authors' knowledge, pharmacists' attitudes toward having a diagnostic role and their diagnostic knowledge and skills have never been studied. To describe pharmacists' attitudes toward the role of diagnosis in pharmacotherapeutic problem-solving and to characterize the extent of pharmacists' knowledge and skills related to diagnostic literacy. Pharmacists working within Lower Mainland Pharmacy Services (British Columbia) who spent at least 33% of their time in direct patient care were invited to participate in a prospective observational survey. The survey sought information about demographic characteristics and attitudes toward diagnosis. Diagnostic knowledge and skills were tested by means of 3 case scenarios. The analysis included simple descriptive statistics and inferential statistics to evaluate relationships between responses and experience and training. Of 266 pharmacists invited to participate, 94 responded. The attitudes section of the survey was completed by 90 pharmacists; of these, 80 (89%) agreed with the definition of "diagnosis" proposed in the survey, and 83 (92%) agreed that it is important for pharmacists to have diagnosis-related skills. Respondents preferred an analytic to a non-analytic approach to diagnostic decision-making. The probabilistic tradition was not the preferred method in any of the 3 cases. In evaluating 5 clinical scenarios that might require diagnostic skills, on average 84% of respondents agreed that they should be involved in assessing such problems. Respondents' knowledge of and ability to apply probabilistic diagnostic tools were highest for test sensitivity (average of 61% of respondents with the correct answers) and lower for test specificity (average of 48% with correct answers) and likelihood ratios (average of 39% with correct answers). Respondents to this survey strongly believed that diagnostic skills were important for solving drug-related problems, but they demonstrated low levels of knowledge and ability to apply concepts of probabilistic diagnostic reasoning. Opportunities to expand pharmacists' knowledge of diagnostic reasoning exist, and the findings reported here indicate that pharmacists would consider such professional development valuable.

  2. Defining Characteristics of Diagnostic Classification Models and the Problem of Retrofitting in Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Gierl, Mark J.; Cui, Ying

    2008-01-01

    One promising application of diagnostic classification models (DCM) is in the area of cognitive diagnostic assessment in education. However, the successful application of DCM in educational testing will likely come with a price--and this price may be in the form of new test development procedures and practices required to yield data that satisfy…

  3. Time- and frequency-dependent model of time-resolved coherent anti-Stokes Raman scattering (CARS) with a picosecond-duration probe pulse

    NASA Astrophysics Data System (ADS)

    Stauffer, Hans U.; Miller, Joseph D.; Slipchenko, Mikhail N.; Meyer, Terrence R.; Prince, Benjamin D.; Roy, Sukesh; Gord, James R.

    2014-01-01

    The hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) technique presents a promising alternative to either fs time-resolved or ps frequency-resolved CARS in both gas-phase thermometry and condensed-phase excited-state dynamics applications. A theoretical description of time-dependent CARS is used to examine this recently developed probe technique, and quantitative comparisons of the full time-frequency evolution show excellent accuracy in predicting the experimental vibrational CARS spectra obtained for two model systems. The interrelated time- and frequency-domain spectral signatures of gas-phase species produced by hybrid fs/ps CARS are explored with a focus on gas-phase N2 vibrational CARS, which is commonly used as a thermometric diagnostic of combusting flows. In particular, we discuss the merits of the simple top-hat spectral filter typically used to generate the ps-duration hybrid fs/ps CARS probe pulse, including strong discrimination against non-resonant background that often contaminates CARS signal. It is further demonstrated, via comparison with vibrational CARS results on a time-evolving solvated organic chromophore, that this top-hat probe-pulse configuration can provide improved spectral resolution, although the degree of improvement depends on the dephasing timescales of the observed molecular modes and the duration and timing of the narrowband final pulse. Additionally, we discuss the virtues of a frequency-domain Lorentzian probe-pulse lineshape and its potential for improving the hybrid fs/ps CARS technique as a diagnostic in high-pressure gas-phase thermometry applications.

  4. Time- and frequency-dependent model of time-resolved coherent anti-Stokes Raman scattering (CARS) with a picosecond-duration probe pulse.

    PubMed

    Stauffer, Hans U; Miller, Joseph D; Slipchenko, Mikhail N; Meyer, Terrence R; Prince, Benjamin D; Roy, Sukesh; Gord, James R

    2014-01-14

    The hybrid femtosecond∕picosecond coherent anti-Stokes Raman scattering (fs∕ps CARS) technique presents a promising alternative to either fs time-resolved or ps frequency-resolved CARS in both gas-phase thermometry and condensed-phase excited-state dynamics applications. A theoretical description of time-dependent CARS is used to examine this recently developed probe technique, and quantitative comparisons of the full time-frequency evolution show excellent accuracy in predicting the experimental vibrational CARS spectra obtained for two model systems. The interrelated time- and frequency-domain spectral signatures of gas-phase species produced by hybrid fs∕ps CARS are explored with a focus on gas-phase N2 vibrational CARS, which is commonly used as a thermometric diagnostic of combusting flows. In particular, we discuss the merits of the simple top-hat spectral filter typically used to generate the ps-duration hybrid fs∕ps CARS probe pulse, including strong discrimination against non-resonant background that often contaminates CARS signal. It is further demonstrated, via comparison with vibrational CARS results on a time-evolving solvated organic chromophore, that this top-hat probe-pulse configuration can provide improved spectral resolution, although the degree of improvement depends on the dephasing timescales of the observed molecular modes and the duration and timing of the narrowband final pulse. Additionally, we discuss the virtues of a frequency-domain Lorentzian probe-pulse lineshape and its potential for improving the hybrid fs∕ps CARS technique as a diagnostic in high-pressure gas-phase thermometry applications.

  5. Energy-resolved neutron imaging for inertial confinement fusion

    NASA Astrophysics Data System (ADS)

    Moran, M. J.; Haan, S. W.; Hatchett, S. P.; Izumi, N.; Koch, J. A.; Lerche, R. A.; Phillips, T. W.

    2003-03-01

    The success of the National Ignition Facility program will depend on diagnostic measurements which study the performance of inertial confinement fusion (ICF) experiments. Neutron yield, fusion-burn time history, and images are examples of important diagnostics. Neutron and x-ray images will record the geometries of compressed targets during the fusion-burn process. Such images provide a critical test of the accuracy of numerical modeling of ICF experiments. They also can provide valuable information in cases where experiments produce unexpected results. Although x-ray and neutron images provide similar data, they do have significant differences. X-ray images represent the distribution of high-temperature regions where fusion occurs, while neutron images directly reveal the spatial distribution of fusion-neutron emission. X-ray imaging has the advantage of a relatively straightforward path to the imaging system design. Neutron imaging, by using energy-resolved detection, offers the intriguing advantage of being able to provide independent images of burning and nonburning regions of the nuclear fuel. The usefulness of energy-resolved neutron imaging depends on both the information content of the data and on the quality of the data that can be recorded. The information content will relate to the characteristic neutron spectra that are associated with emission from different regions of the source. Numerical modeling of ICF fusion burn will be required to interpret the corresponding energy-dependent images. The exercise will be useful only if the images can be recorded with sufficient definition to reveal the spatial and energy-dependent features of interest. Several options are being evaluated with respect to the feasibility of providing the desired simultaneous spatial and energy resolution.

  6. Educational consequences of developmental speech disorder: Key Stage 1 National Curriculum assessment results in English and mathematics.

    PubMed

    Nathan, Liz; Stackhouse, Joy; Goulandris, Nata; Snowling, Margaret J

    2004-06-01

    Children with speech difficulties may have associated educational problems. This paper reports a study examining the educational attainment of children at Key Stage 1 of the National Curriculum who had previously been identified with a speech difficulty. (1) To examine the educational attainment at Key Stage 1 of children diagnosed with speech difficulties two/three years prior to the present study. (2) To compare the Key Stage 1 assessment results of children whose speech problems had resolved at the time of assessment with those whose problems persisted. Data were available from 39 children who had an earlier diagnosis of speech difficulties at age 4/5 (from an original cohort of 47) at the age of 7. A control group of 35 children identified and matched at preschool on age, nonverbal ability and gender provided comparative data. Results of Statutory Assessment Tests (SATs) in reading, reading comprehension, spelling, writing and maths, administered to children at the end of Year 2 of school were analysed. Performance across the two groups was compared. Performance was also compared to published statistics on national levels of attainment. Children with a history of speech difficulties performed less well than controls on reading, spelling and maths. However, children whose speech problems had resolved by the time of assessment performed no differently to controls. Children with persisting speech problems performed less well than controls on tests of literacy and maths. Spelling performance was a particular area of difficulty for children with persisting speech problems. Children with speech difficulties are likely to perform less well than expected on literacy and maths SAT's at age 7. Performance is related to whether the speech problem resolves early on and whether associated language problems exist. Whilst it is unclear whether poorer performance on maths is because of the language components of this task, the results indicate that speech problems, especially persisting ones, can affect the ability to access the National Curriculum to expected levels.

  7. Diagnostics of breast cancer by analysis of spectra diffuse reflections

    NASA Astrophysics Data System (ADS)

    Kuzmina, Natalya V.; Plaksin, Fedor G.; Polovnikov, Eugeny S.

    2001-05-01

    The work is dedicated to problems of diagnostic oncologic diseases by a spectroscopic-optical method and is prolongation of long-term examinations held earlier by Vovk S.M, Naumov S.A. and Pushkarev S.V. The actual spectra of a diffuse reflection removed in vivo and in vitro are given, is angry- and good-quality neoplasms, healthy tissue and blood of breast and other organs. Problems of a clinical oncology are in a center of attention in medicine because the cases of disease malignant swellings increase, which is stipulated by an irregularity of present methods of diagnostic.

  8. Some Cognitive Components of the Diagnostic Thinking Process.

    ERIC Educational Resources Information Center

    Gale, Janet

    1982-01-01

    Identifies 14 cognitive components of the diagnostic thinking process in clinical problem solving. Analyzes the differences between medical students, hospital house officers, and hospital registrars in London, England, on the relative use of such thinking processes. Suggests that diagnostic thinking processes cannot be incorporated into medical…

  9. Diagnostics and results from coaxial plasma gun development for the PLX- α project

    NASA Astrophysics Data System (ADS)

    Case, A.; Brockington, S.; Cruz, E.; Witherspoon, F. D.

    2016-10-01

    We present results from the diagnostics used during development of the contoured gap coaxial plasma guns for the PLX- α project at LANL. Plasma-jet diagnostics include fast photodiodes for velocimetry, a ballistic pendulum for total plasmoid momentum, and interferometry for line integrated density. Deflectometry will be used for line integrated perpendicular density gradients. Time-resolved high-resolution spectroscopy using a novel detector and time-integrated survey spectroscopy are used for measurements of velocity and temperature, as well as impurities. We will also use a Faraday cup for density, fast imaging for plume geometry, and time-integrated imaging for overall light emission. Experimental results are compared to the desired target parameters for the plasma jets (up to n 2 ×1016cm-3 , v 50km / s , mass 5gm , radius = 4cm , and length 10cm). This work supported by the ARPA-E ALPHA Program.

  10. A temporally and spatially resolved electron density diagnostic method for the edge plasma based on Stark broadening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zafar, A., E-mail: zafara@ornl.gov; Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830; Martin, E. H.

    2016-11-15

    An electron density diagnostic (≥10{sup 10} cm{sup −3}) capable of high temporal (ms) and spatial (mm) resolution is currently under development at Oak Ridge National Laboratory. The diagnostic is based on measuring the Stark broadened, Doppler-free spectral line profile of the n = 6–2 hydrogen Balmer series transition. The profile is then fit to a fully quantum mechanical model including the appropriate electric and magnetic field operators. The quasi-static approach used to calculate the Doppler-free spectral line profile is outlined here and the results from the model are presented for H-δ spectra for electron densities of 10{sup 10}–10{sup 13} cm{supmore » −3}. The profile shows complex behavior due to the interaction between the magnetic substates of the atom.« less

  11. Hyperspectral fluorescence imaging system for biomedical diagnostics

    NASA Astrophysics Data System (ADS)

    Martin, Matthew E.; Wabuyele, Musundi B.; Panjehpour, Masoud; Phan, Mary N.; Overholt, Bergein F.; Vo-Dinh, Tuan

    2006-02-01

    An advanced hyper-spectral imaging (HSI) system has been developed for use in medical diagnostics. One such diagnostic, esophageal cancer is diagnosed currently through biopsy and subsequent pathology. The end goal of this research is to develop an optical-based technique to assist or replace biopsy. In this paper, we demonstrate an instrument that has the capability to optically diagnose cancer in laboratory mice. We have developed a real-time HSI system based on state-of-the-art liquid crystal tunable filter (LCTF) technology coupled to an endoscope. This unique HSI technology is being developed to obtain spatially resolved images of the slight differences in luminescent properties of normal versus tumorous tissues. In this report, an in-vivo mouse study is shown. A predictive measure of cancer for the mice studied is developed and shown. It is hoped that the results of this study will lead to advances in the optical diagnosis of esophageal cancer in humans.

  12. Making judgments about ability: the role of implicit theories of ability in moderating inferences from temporal and social comparison information.

    PubMed

    Butler, R

    2000-05-01

    Two studies examined the novel proposal that implicit theories of intelligence (C. S. Dweck & E. L. Leggett, 1988) moderate both the effects of performance trends on ability inferences and the perceived diagnosticity of temporal versus normative feedback. Results from 613 adolescents and 42 teachers confirmed that entity theorists perceived initial outcome as more diagnostic and inferred higher ability in another (Study 1) and in the self (Study 2) in a declining outcome condition; incremental theorists perceived last outcome as more diagnostic and inferred higher ability in an ascending condition. Experimental induction of beliefs about ability had similar effects. As predicted, self-appraisal was affected more by temporal feedback among incremental theorists and by normative feedback among entity theorists. Results help resolve prior mixed findings regarding order effects and responses to temporal and normative evaluation.

  13. Bayesian tomography and integrated data analysis in fusion diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Dong, E-mail: lid@swip.ac.cn; Dong, Y. B.; Deng, Wei

    2016-11-15

    In this article, a Bayesian tomography method using non-stationary Gaussian process for a prior has been introduced. The Bayesian formalism allows quantities which bear uncertainty to be expressed in the probabilistic form so that the uncertainty of a final solution can be fully resolved from the confidence interval of a posterior probability. Moreover, a consistency check of that solution can be performed by checking whether the misfits between predicted and measured data are reasonably within an assumed data error. In particular, the accuracy of reconstructions is significantly improved by using the non-stationary Gaussian process that can adapt to the varyingmore » smoothness of emission distribution. The implementation of this method to a soft X-ray diagnostics on HL-2A has been used to explore relevant physics in equilibrium and MHD instability modes. This project is carried out within a large size inference framework, aiming at an integrated analysis of heterogeneous diagnostics.« less

  14. Infrared Imaging Tools for Diagnostic Applications in Dermatology.

    PubMed

    Gurjarpadhye, Abhijit Achyut; Parekh, Mansi Bharat; Dubnika, Arita; Rajadas, Jayakumar; Inayathullah, Mohammed

    Infrared (IR) imaging is a collection of non-invasive imaging techniques that utilize the IR domain of the electromagnetic spectrum for tissue assessment. A subset of these techniques construct images using back-reflected light, while other techniques rely on detection of IR radiation emitted by the tissue as a result of its temperature. Modern IR detectors sense thermal emissions and produce a heat map of surface temperature distribution in tissues. Thus, the IR spectrum offers a variety of imaging applications particularly useful in clinical diagnostic area, ranging from high-resolution, depth-resolved visualization of tissue to temperature variation assessment. These techniques have been helpful in the diagnosis of many medical conditions including skin/breast cancer, arthritis, allergy, burns, and others. In this review, we discuss current roles of IR-imaging techniques for diagnostic applications in dermatology with an emphasis on skin cancer, allergies, blisters, burns and wounds.

  15. In-situ material-motion diagnostics and fuel radiography in experimental reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVolpi, A.

    1982-01-01

    Material-motion monitoring has become a routine part of in-pile transient reactor-safety experiments. Diagnostic systems, such as the fast-neutron hodoscope, were developed for the purpose of providing direct time-resolved data on pre-failure fuel motion, cladding-breach time and location, and post-failure fuel relocation. Hodoscopes for this purpose have been installed at TREAT and CABRI; other types of imaging systems that have been tested are a coded-aperture at ACRR and a pinhole at TREAT. Diagnostic systems that use penetrating radiation emitted from the test section can non-invasively monitor fuel without damage to the measuring instrument during the radiographic images of test sections installedmore » in the reator. Studies have been made of applications of hodoscopes to other experimental reactors, including PBF, FARET, STF, ETR, EBR-II, SAREF-STF, and DMT.« less

  16. Mid-infrared Laser Absorption Diagnostics for Detonation Studies

    NASA Astrophysics Data System (ADS)

    Spearrin, R. M.; Goldenstein, C. S.; Jeffries, J. B.; Hanson, R. K.

    Detonation-based engines represent a challenging application for diagnostics due to the wide range of thermodynamic conditions involved (T~500-3000 K, P~2-60 atm) and the short time scales of change (~10- 6 to 10- 4 sec) associated with such systems. Non-intrusive laser absorption diagnostics can provide high time-resolution and have been employed extensively in shock tube kinetics experiments (P~1-20 atm), offering high potential for application in detonation environments with modest utilization to date [1-4]. Limiting factors in designing effective tunable laser absorption sensors for detonation engines can be divided into two sets of challenges: high-pressure, high-temperature absorption spectroscopy and harsh thermo-mechanical environments. The present work, conducted in a high-pressure shock tube and operating detonation combustor, addresses both sets of difficulties, with the objective of developing time-resolved, in-situ temperature and concentration sensors for detonation studies.

  17. Use of computer modeling to investigate a dynamic interaction problem in the Skylab TACS quad-valve package

    NASA Technical Reports Server (NTRS)

    Hesser, R. J.; Gershman, R.

    1975-01-01

    A valve opening-response problem encountered during development of a control valve for the Skylab thruster attitude control system (TACS) is described. The problem involved effects of dynamic interaction among valves in the quad-redundant valve package. Also described is a detailed computer simulation of the quad-valve package which was helpful in resolving the problem.

  18. Contrast-enhanced spectral mammography in patients with MRI contraindications.

    PubMed

    Richter, Vivien; Hatterman, Valerie; Preibsch, Heike; Bahrs, Sonja D; Hahn, Markus; Nikolaou, Konstantin; Wiesinger, Benjamin

    2017-01-01

    Background Contrast-enhanced spectral mammography (CESM) is a novel breast imaging technique providing comparable diagnostic accuracy to breast magnetic resonance imaging (MRI). Purpose To show that CESM in patients with MRI contraindications is feasible, accurate, and useful as a problem-solving tool, and to highlight its limitations. Material and Methods A total of 118 patients with MRI contraindications were examined by CESM. Histology was obtained in 94 lesions and used as gold standard for diagnostic accuracy calculations. Imaging data were reviewed retrospectively for feasibility, accuracy, and technical problems. The diagnostic yield of CESM as a problem-solving tool and for therapy response evaluation was reviewed separately. Results CESM was more accurate than mammography (MG) for lesion categorization (r = 0.731, P < 0.0001 vs. r = 0.279, P = 0.006) and for lesion size estimation (r = 0.738 vs. r = 0.689, P < 0.0001). Negative predictive value of CESM was significantly higher than of MG (85.71% vs. 30.77%, P < 0.0001). When used for problem-solving, CESM changed patient management in 2/8 (25%) cases. Superposition artifacts and timing problems affected diagnostic utility in 3/118 (2.5%) patients. Conclusion CESM is a feasible and accurate alternative for patients with MRI contraindications, but it is necessary to be aware of the method's technical limitations.

  19. Qualification and implementation of line ratio spectroscopy on helium as plasma edge diagnostic at ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Griener, M.; Muñoz Burgos, J. M.; Cavedon, M.; Birkenmeier, G.; Dux, R.; Kurzan, B.; Schmitz, O.; Sieglin, B.; Stroth, U.; Viezzer, E.; Wolfrum, E.; the ASDEX Upgrade Team

    2018-02-01

    A new thermal helium beam diagnostic has been implemented as plasma edge diagnostic at the ASDEX Upgrade (AUG) tokamak. The helium beam is built to measure the electron density n e and temperature T e simultaneously with high spatial and temporal resolution in order to investigate steady-state as well as fast transport processes in the plasma edge region. For the thermal helium beam emission line ratio spectroscopy, neutral helium is locally injected into the plasma by a piezo valve. This enabled the measurement of the line resolved emission intensities of seven He I lines for different plasma scenarios in AUG. The different line ratios can be used together with a collisional-radiative model (CRM) to reconstruct the underlying electron temperature and density. Ratios from the same spin species are used for the electron density reconstruction, whereas spin mixed ratios are sensitive to electron temperature changes. The different line ratios as well as different CRMs are tested for their suitability for diagnostic applications. Furthermore their consistency in calculating identical parameters is validated and the resulting profiles are compared to other available diagnostics at AUG.

  20. Parametric Thermal and Flow Analysis of ITER Diagnostic Shield Module

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khodak, A.; Zhai, Y.; Wang, W.

    As part of the diagnostic port plug assembly, the ITER Diagnostic Shield Module (DSM) is designed to provide mechanical support and the plasma shielding while allowing access to plasma diagnostics. Thermal and hydraulic analysis of the DSM was performed using a conjugate heat transfer approach, in which heat transfer was resolved in both solid and liquid parts, and simultaneously, fluid dynamics analysis was performed only in the liquid part. ITER Diagnostic First Wall (DFW) and cooling tubing were also included in the analysis. This allowed direct modeling of the interface between DSM and DFW, and also direct assessment of themore » coolant flow distribution between the parts of DSM and DFW to ensure DSM design meets the DFW cooling requirements. Design of the DSM included voids filled with Boron Carbide pellets, allowing weight reduction while keeping shielding capability of the DSM. These voids were modeled as a continuous solid with smeared material properties using analytical relation for thermal conductivity. Results of the analysis lead to design modifications improving heat transfer efficiency of the DSM. Furthermore, the effect of design modifications on thermal performance as well as effect of Boron Carbide will be presented.« less

  1. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    PubMed

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  2. Parametric Thermal and Flow Analysis of ITER Diagnostic Shield Module

    DOE PAGES

    Khodak, A.; Zhai, Y.; Wang, W.; ...

    2017-06-19

    As part of the diagnostic port plug assembly, the ITER Diagnostic Shield Module (DSM) is designed to provide mechanical support and the plasma shielding while allowing access to plasma diagnostics. Thermal and hydraulic analysis of the DSM was performed using a conjugate heat transfer approach, in which heat transfer was resolved in both solid and liquid parts, and simultaneously, fluid dynamics analysis was performed only in the liquid part. ITER Diagnostic First Wall (DFW) and cooling tubing were also included in the analysis. This allowed direct modeling of the interface between DSM and DFW, and also direct assessment of themore » coolant flow distribution between the parts of DSM and DFW to ensure DSM design meets the DFW cooling requirements. Design of the DSM included voids filled with Boron Carbide pellets, allowing weight reduction while keeping shielding capability of the DSM. These voids were modeled as a continuous solid with smeared material properties using analytical relation for thermal conductivity. Results of the analysis lead to design modifications improving heat transfer efficiency of the DSM. Furthermore, the effect of design modifications on thermal performance as well as effect of Boron Carbide will be presented.« less

  3. High-accuracy resolver-to-digital conversion via phase locked loop based on PID controller

    NASA Astrophysics Data System (ADS)

    Li, Yaoling; Wu, Zhong

    2018-03-01

    The problem of resolver-to-digital conversion (RDC) is transformed into the problem of angle tracking control, and a phase locked loop (PLL) method based on PID controller is proposed in this paper. This controller comprises a typical PI controller plus an incomplete differential which can avoid the amplification of higher-frequency noise components by filtering the phase detection error with a low-pass filter. Compared with conventional ones, the proposed PLL method makes the converter a system of type III and thus the conversion accuracy can be improved. Experimental results demonstrate the effectiveness of the proposed method.

  4. Time-resolved EPR spectroscopy in a Unix environment.

    PubMed

    Lacoff, N M; Franke, J E; Warden, J T

    1990-02-01

    A computer-aided time-resolved electron paramagnetic resonance (EPR) spectrometer implemented under version 2.9 BSD Unix was developed by interfacing a Varian E-9 EPR spectrometer and a Biomation 805 waveform recorder to a PDP-11/23A minicomputer having MINC A/D and D/A capabilities. Special problems with real-time data acquisition in a multiuser, multitasking Unix environment, addressing of computer main memory for the control of hardware devices, and limitation of computer main memory were resolved, and their solutions are presented. The time-resolved EPR system and the data acquisition and analysis programs, written entirely in C, are described. Furthermore, the benefits of utilizing the Unix operating system and the C language are discussed, and system performance is illustrated with time-resolved EPR spectra of the reaction center cation in photosystem 1 of green plant photosynthesis.

  5. Electron density in surface barrier discharge emerging at argon/water interface: quantification for streamers and leaders

    NASA Astrophysics Data System (ADS)

    Cvetanović, Nikola; Galmiz, Oleksandr; Synek, Petr; Zemánek, Miroslav; Brablec, Antonín; Hoder, Tomáš

    2018-02-01

    Optical emission spectroscopy, fast intensified CCD imaging and electrical measurements were applied to investigate the basic plasma parameters of surface barrier discharge emerging from a conductive water electrode. The discharge was generated at the triple-line interface of atmospheric pressure argon gas and conductive water solution at the fused silica dielectrics using a sinusoidal high-voltage waveform. The spectroscopic methods of atomic line broadening and molecular spectroscopy were used to determine the electron densities and the gas temperature in the active plasma. These parameters were obtained for both applied voltage polarities and resolved spatially. Two different spectral signatures were identified in the spatially resolved spectra resulting in electron densities differing by two orders of magnitude. It is shown that two discharge mechanisms take a place: the streamer and the leader one, with electron densities of 1014 and 1016 cm-3, respectively. This spectroscopic evidence is supported by the combined diagnostics of electrical current measurements and phase-resolved intensified CCD camera imaging.

  6. Seasonality of eddy kinetic energy in an eddy permitting global climate model

    NASA Astrophysics Data System (ADS)

    Uchida, Takaya; Abernathey, Ryan; Smith, Shafer

    2017-10-01

    We examine the seasonal cycle of upper-ocean mesoscale turbulence in a high resolution CESM climate simulation. The ocean model component (POP) has 0.1° resolution, mesoscale resolving at low and middle latitudes. Seasonally and regionally resolved wavenumber power spectra are calculated for sea-surface eddy kinetic energy (EKE). Although the interpretation of the spectral slopes in terms of turbulence theory is complicated by the strong presence of dissipation and the narrow inertial range, the EKE spectra consistently show higher power at small scales during winter throughout the ocean. Potential hypotheses for this seasonality are investigated. Diagnostics of baroclinc energy conversion rates and evidence from linear quasigeostrophic stability analysis indicate that seasonally varying mixed-layer instability is responsible for the seasonality in EKE. The ability of this climate model, which is not considered submesoscale resolving, to produce mixed layer instability although damped by dissipation, demonstrates the ubiquity and robustness of this process for modulating upper ocean EKE.

  7. Analysis and implementation of a space resolving spherical crystal spectrometer for x-ray Thomson scattering experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harding, E. C.; Ao, T.; Bailey, J. E.

    2015-04-15

    The application of a space-resolving spectrometer to X-ray Thomson Scattering (XRTS) experiments has the potential to advance the study of warm dense matter. This has motivated the design of a spherical crystal spectrometer, which is a doubly focusing geometry with an overall high sensitivity and the capability of providing high-resolution, space-resolved spectra. A detailed analysis of the image fluence and crystal throughput in this geometry is carried out and analytical estimates of these quantities are presented. This analysis informed the design of a new spectrometer intended for future XRTS experiments on the Z-machine. The new spectrometer collects 6 keV x-raysmore » with a spherically bent Ge (422) crystal and focuses the collected x-rays onto the Rowland circle. The spectrometer was built and then tested with a foam target. The resulting high-quality spectra prove that a spherical spectrometer is a viable diagnostic for XRTS experiments.« less

  8. Analysis and implementation of a space resolving spherical crystal spectrometer for x-ray Thomson scattering experiments.

    PubMed

    Harding, E C; Ao, T; Bailey, J E; Loisel, G; Sinars, D B; Geissel, M; Rochau, G A; Smith, I C

    2015-04-01

    The application of a space-resolving spectrometer to X-ray Thomson Scattering (XRTS) experiments has the potential to advance the study of warm dense matter. This has motivated the design of a spherical crystal spectrometer, which is a doubly focusing geometry with an overall high sensitivity and the capability of providing high-resolution, space-resolved spectra. A detailed analysis of the image fluence and crystal throughput in this geometry is carried out and analytical estimates of these quantities are presented. This analysis informed the design of a new spectrometer intended for future XRTS experiments on the Z-machine. The new spectrometer collects 6 keV x-rays with a spherically bent Ge (422) crystal and focuses the collected x-rays onto the Rowland circle. The spectrometer was built and then tested with a foam target. The resulting high-quality spectra prove that a spherical spectrometer is a viable diagnostic for XRTS experiments.

  9. Spatially unresolved SED fitting can underestimate galaxy masses: a solution to the missing mass problem

    NASA Astrophysics Data System (ADS)

    Sorba, Robert; Sawicki, Marcin

    2018-05-01

    We perform spatially resolved, pixel-by-pixel Spectral Energy Distribution (SED) fitting on galaxies up to z ˜ 2.5 in the Hubble eXtreme Deep Field (XDF). Comparing stellar mass estimates from spatially resolved and spatially unresolved photometry we find that unresolved masses can be systematically underestimated by factors of up to 5. The ratio of the unresolved to resolved mass measurement depends on the galaxy's specific star formation rate (sSFR): at low sSFRs the bias is small, but above sSFR ˜ 10-9.5 yr-1 the discrepancy increases rapidly such that galaxies with sSFRs ˜ 10-8 yr-1 have unresolved mass estimates of only one-half to one-fifth of the resolved value. This result indicates that stellar masses estimated from spatially unresolved data sets need to be systematically corrected, in some cases by large amounts, and we provide an analytic prescription for applying this correction. We show that correcting stellar mass measurements for this bias changes the normalization and slope of the star-forming main sequence and reduces its intrinsic width; most dramatically, correcting for the mass bias increases the stellar mass density of the Universe at high redshift and can resolve the long-standing discrepancy between the directly measured cosmic SFR density at z ≳ 1 and that inferred from stellar mass densities (`the missing mass problem').

  10. Likelihood-Based Clustering of Meta-Analytic SROC Curves

    ERIC Educational Resources Information Center

    Holling, Heinz; Bohning, Walailuck; Bohning, Dankmar

    2012-01-01

    Meta-analysis of diagnostic studies experience the common problem that different studies might not be comparable since they have been using a different cut-off value for the continuous or ordered categorical diagnostic test value defining different regions for which the diagnostic test is defined to be positive. Hence specificities and…

  11. Problem Representation, Background Evidence, Analysis, Recommendation: An Oral Case Presentation Tool to Promote Diagnostic Reasoning.

    PubMed

    Carter, Cristina; Akar-Ghibril, Nicole; Sestokas, Jeff; Dixon, Gabrina; Bradford, Wilhelmina; Ottolini, Mary

    2018-03-01

    Oral case presentations provide an opportunity for trainees to communicate diagnostic reasoning at the bedside. However, few tools exist to enable faculty to provide effective feedback. We developed a tool to assess diagnostic reasoning and communication during oral case presentations. Published by Elsevier Inc.

  12. A fully-integrated aptamer-based affinity assay platform for monitoring astronaut health in space.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xianbin; Durland, Ross H.; Hecht, Ariel H.

    2010-07-01

    Here we demonstrate the suitability of robust nucleic acid affinity reagents in an integrated point-of-care diagnostic platform for monitoring proteomic biomarkers indicative of astronaut health in spaceflight applications. A model thioaptamer targeting nuclear factor-kappa B (NF-{kappa}B) is evaluated in an on-chip electrophoretic gel-shift assay for human serum. Key steps of (i) mixing sample with the aptamer, (ii) buffer exchange, and (iii) preconcentration of sample were successfully integrated upstream of fluorescence-based detection. Challenges due to (i) nonspecific interactions with serum, and (ii) preconcentration at a nanoporous membrane are discussed and successfully resolved to yield a robust, rapid, and fully-integrated diagnostic system.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbajal, L.; Warwick Univ., Coventry; Dendy, R. O.

    Ion cyclotron emission (ICE) offers unique promise as a diagnostic of the fusion born alpha-particle population in magnetically confined plasmas. Pioneering observations from JET and TFTR found that ICE intensity P ICE scales approximately linearly with the measured neutron flux from fusion reactions, and with the inferred concentration, n /n i , of fusion-born alpha-particles confined within the plasma. We present fully nonlinear self-consistent kinetic simulations that reproduce this scaling for the first time. This resolves a longstanding question in the physics of fusion alpha particle confinement and stability in MCF plasmas. It confirms the MCI as the likely emissionmore » mechanism and greatly strengthens the basis for diagnostic exploitation of ICE in future burning plasmas.« less

  14. Omega Dante soft x-ray power diagnostic component calibration at the National Synchrotron Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, K.M.; Weber, F.A.; Dewald, E.L.

    2004-10-01

    The Dante soft x-ray spectrometer, installed on the Omega laser facility at the Laboratory for Laser Energetics, University of Rochester, is a 12-channel filter-edge defined soft x-ray power diagnostic. It is used to measure the spectrally resolved, absolute flux from direct drive, indirect drive (hohlraums) and other plasma sources. Dante component calibration efforts using two beam lines, U3C (50 eV-1 keV) and X8A (1-6 keV) at the National Synchrotron Light Source have been implemented to improve the accuracy of these measurements. We have calibrated metallic vacuum x-ray diodes, mirrors and filters.

  15. Dog and Cat Allergies: Current State of Diagnostic Approaches and Challenges

    PubMed Central

    Chan, Sanny K.

    2018-01-01

    Allergies to dogs and cats affect 10%–20% of the population worldwide and is a growing public health concern as these rates increase. Given the prevalence of detectable dog and cat allergens even in households without pets, there is a critical need to accurately diagnose and treat patients to reduce morbidity and mortality from exposure. The ability to diagnose cat sensitization is good, in contrast to dogs. Component resolved diagnostics of sensitization to individual allergenic proteins will dramatically improve diagnosis. This review focuses on the current state of knowledge regarding allergies to dogs and cats, recent advances, therapies such as subcutaneous immunotherapy, and discusses important areas to improve diagnosis and therapy. PMID:29411550

  16. A Three-Tier Diagnostic Test to Assess Pre-Service Teachers' Misconceptions about Global Warming, Greenhouse Effect, Ozone Layer Depletion, and Acid Rain

    ERIC Educational Resources Information Center

    Arslan, Harika Ozge; Cigdemoglu, Ceyhan; Moseley, Christine

    2012-01-01

    This study describes the development and validation of a three-tier multiple-choice diagnostic test, the atmosphere-related environmental problems diagnostic test (AREPDiT), to reveal common misconceptions of global warming (GW), greenhouse effect (GE), ozone layer depletion (OLD), and acid rain (AR). The development of a two-tier diagnostic test…

  17. Twitter as a Tool for Conservation Education and Outreach: What Scientific Conferences Can Do to Promote Live-Tweeting

    ERIC Educational Resources Information Center

    Shiffman, D. S.

    2012-01-01

    If more conservation-minded citizens were aware of certain environmental threats and how to resolve them, these issues could be resolved more effectively. Scientific conferences focusing on conservation bring together countless experts on environmental problems and solutions, but are not an effective means of reaching the interested public on a…

  18. The Co-Teaching Journey: A Systematic Grounded Theory Study Investigating How Secondary School Teachers Resolve Challenges in Co-Teaching

    ERIC Educational Resources Information Center

    Gerst, Sharon

    2012-01-01

    The purpose of this systematic grounded theory study was to explain how problems inherent in co-teaching relationships are resolved by secondary school special education and general education teachers at an urban school district in Eastern Iowa. The participants were general and special education secondary school teachers involved in effective…

  19. Appropriate Minimal Dose of Gadobutrol for 3D Time-Resolved MRA of the Supra-Aortic Arteries: Comparison with Conventional Single-Phase High-Resolution 3D Contrast-Enhanced MRA.

    PubMed

    Bak, S H; Roh, H G; Moon, W-J; Choi, J W; An, H S

    2017-07-01

    The development of nephrogenic systemic fibrosis and neural tissue deposition is gadolinium dose-dependent. The purpose of this study was to determine the appropriate minimal dose of gadobutrol with time-resolved MRA to assess supra-aortic arterial stenosis with contrast-enhanced MRA as a reference standard. Four hundred sixty-two consecutive patients underwent both standard-dose contrast-enhanced MRA and low-dose time-resolved MRA and were classified into 3 groups; group A (a constant dose of 1 mL for time-resolved MRA), group B (2 mL), or group C (3 mL). All studies were independently evaluated by 2 radiologists for image quality by using a 5-point scale (from 0 = failure to 4 = excellent), grading of arterial stenosis (0 = normal, 1 = mild [<30%], 2 = moderate [30%-69%], 3 = severe to occlusion [≥70%]), and signal-to-noise ratio. The image quality of time-resolved MRA was similar to that of contrast-enhanced MRA in groups B and C, but it was inferior to contrast-enhanced MRA in group A. For the grading of arterial stenosis, there was an excellent correlation between contrast-enhanced MRA and time-resolved MRA ( R = 0.957 for group A, R = 0.988 for group B, R = 0.991 for group C). The SNR of time-resolved MRA tended to be lower than that of contrast-enhanced MRA in groups A and B. However, SNR was higher for time-resolved MRA compared with contrast-enhanced MRA in group C. Low-dose time-resolved MRA is feasible in the evaluation of supra-aortic stenosis and could be used as an alternative to contrast-enhanced MRA for a diagnostic technique in high-risk populations. © 2017 by American Journal of Neuroradiology.

  20. Noninvasive diagnostics of skin microphysical parameters based on spatially resolved diffuse reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Lisenko, S. A.; Kugeiko, M. M.

    2013-01-01

    The ability to determine noninvasively microphysical parameters (MPPs) of skin characteristic of malignant melanoma was demonstrated. The MPPs were the melanin content in dermis, saturation of tissue with blood vessels, and concentration and effective size of tissue scatterers. The proposed method was based on spatially resolved spectral measurements of skin diffuse reflectance and multiple regressions between linearly independent measurement components and skin MPPs. The regressions were established by modeling radiation transfer in skin with a wide variation of its MPPs. Errors in the determination of skin MPPs were estimated using fiber-optic measurements of its diffuse reflectance at wavelengths of commercially available semiconductor diode lasers (578, 625, 660, 760, and 806 nm) at source-detector separations of 0.23-1.38 mm.

  1. Quantitative Detection of Nucleoside Analogues by Multi-enzyme Biosensors using Time-Resolved Kinetic Measurements.

    PubMed

    Muthu, Pravin; Lutz, Stefan

    2016-04-05

    Fast, simple and cost-effective methods for detecting and quantifying pharmaceutical agents in patients are highly sought after to replace equipment and labor-intensive analytical procedures. The development of new diagnostic technology including portable detection devices also enables point-of-care by non-specialists in resource-limited environments. We have focused on the detection and dose monitoring of nucleoside analogues used in viral and cancer therapies. Using deoxyribonucleoside kinases (dNKs) as biosensors, our chemometric model compares observed time-resolved kinetics of unknown analytes to known substrate interactions across multiple enzymes. The resulting dataset can simultaneously identify and quantify multiple nucleosides and nucleoside analogues in complex sample mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Divertor electron temperature and impurity diffusion measurements with a spectrally resolved imaging radiometer.

    PubMed

    Clayton, D J; Jaworski, M A; Kumar, D; Stutman, D; Finkenthal, M; Tritz, K

    2012-10-01

    A divertor imaging radiometer (DIR) diagnostic is being studied to measure spatially and spectrally resolved radiated power P(rad)(λ) in the tokamak divertor. A dual transmission grating design, with extreme ultraviolet (~20-200 Å) and vacuum ultraviolet (~200-2000 Å) gratings placed side-by-side, can produce coarse spectral resolution over a broad wavelength range covering emission from impurities over a wide temperature range. The DIR can thus be used to evaluate the separate P(rad) contributions from different ion species and charge states. Additionally, synthetic spectra from divertor simulations can be fit to P(rad)(λ) measurements, providing a powerful code validation tool that can also be used to estimate electron divertor temperature and impurity transport.

  3. A Real-Life Case Study of Audit Interactions--Resolving Messy, Complex Problems

    ERIC Educational Resources Information Center

    Beattie, Vivien; Fearnley, Stella; Hines, Tony

    2012-01-01

    Real-life accounting and auditing problems are often complex and messy, requiring the synthesis of technical knowledge in addition to the application of generic skills. To help students acquire the necessary skills to deal with these problems effectively, educators have called for the use of case-based methods. Cases based on real situations (such…

  4. Analyzing Multilevel Data: An Empirical Comparison of Parameter Estimates of Hierarchical Linear Modeling and Ordinary Least Squares Regression

    ERIC Educational Resources Information Center

    Rocconi, Louis M.

    2011-01-01

    Hierarchical linear models (HLM) solve the problems associated with the unit of analysis problem such as misestimated standard errors, heterogeneity of regression and aggregation bias by modeling all levels of interest simultaneously. Hierarchical linear modeling resolves the problem of misestimated standard errors by incorporating a unique random…

  5. The Diagnostic/Therapeutic Preabortion Interview.

    ERIC Educational Resources Information Center

    Boekelheide, Priscilla Day

    1978-01-01

    The therapeutic and diagnostic aspect of the preabortion interview are discussed with attention to specifics that will identify students with the greatest likelihood for psychological problems and/or repeat abortions. (JD)

  6. Dust measurements in tokamaks (invited).

    PubMed

    Rudakov, D L; Yu, J H; Boedo, J A; Hollmann, E M; Krasheninnikov, S I; Moyer, R A; Muller, S H; Pigarov, A Yu; Rosenberg, M; Smirnov, R D; West, W P; Boivin, R L; Bray, B D; Brooks, N H; Hyatt, A W; Wong, C P C; Roquemore, A L; Skinner, C H; Solomon, W M; Ratynskaia, S; Fenstermacher, M E; Groth, M; Lasnier, C J; McLean, A G; Stangeby, P C

    2008-10-01

    Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers, visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 microm in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C(2) dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudakov, D. L.; Yu, J. H.; Boedo, J. A.

    Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers,more » visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 {mu}m in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C{sub 2} dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.« less

  8. The resolution of point sources of light as analyzed by quantum detection theory

    NASA Technical Reports Server (NTRS)

    Helstrom, C. W.

    1972-01-01

    The resolvability of point sources of incoherent light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  9. Miniaturized Plasma and Neutral Diagnostics for JIMO

    NASA Technical Reports Server (NTRS)

    McHarg, M. G.; Enloe, C. L.; Krause, L. A.; Herrero, F. A.

    2003-01-01

    We describe a miniaturized suite of instruments which provides both bulk energy resolved plasma properties and coarse neutral mass spectroscopy suitable for measurements on the Jupiter Icy Moons Orbiter (JIMO). The suite is comprised of two instruments; the Miniaturized Electro-Static Analyzer (MESA), and the Flat Plasma Spectrometer (FLAPS), designed to measure the near earth environment on the Air Force Academy small satellite missions Falconsat-2 and 3.

  10. Combustion Diagnostics and Flow Visualization of Hypergolic Combustion and Gelled Mixing Behavior

    DTIC Science & Technology

    1997-12-19

    difference. Also, Exciplex Flourescence imaging has been implented to visualize diffusion layers which form at the contact interface of mixing...have been implemented and developed as a result of this effort. Among these techniques the most noteworthy involves a unique application of Exciplex ...fluorescence for visualization of diffusion layers formed between mixing liquids. Time resolved images of Exciplex fluorescence have been obtained

  11. Polynomial-time solution of prime factorization and NP-complete problems with digital memcomputing machines

    NASA Astrophysics Data System (ADS)

    Traversa, Fabio L.; Di Ventra, Massimiliano

    2017-02-01

    We introduce a class of digital machines, we name Digital Memcomputing Machines, (DMMs) able to solve a wide range of problems including Non-deterministic Polynomial (NP) ones with polynomial resources (in time, space, and energy). An abstract DMM with this power must satisfy a set of compatible mathematical constraints underlying its practical realization. We prove this by making a connection with the dynamical systems theory. This leads us to a set of physical constraints for poly-resource resolvability. Once the mathematical requirements have been assessed, we propose a practical scheme to solve the above class of problems based on the novel concept of self-organizing logic gates and circuits (SOLCs). These are logic gates and circuits able to accept input signals from any terminal, without distinction between conventional input and output terminals. They can solve boolean problems by self-organizing into their solution. They can be fabricated either with circuit elements with memory (such as memristors) and/or standard MOS technology. Using tools of functional analysis, we prove mathematically the following constraints for the poly-resource resolvability: (i) SOLCs possess a global attractor; (ii) their only equilibrium points are the solutions of the problems to solve; (iii) the system converges exponentially fast to the solutions; (iv) the equilibrium convergence rate scales at most polynomially with input size. We finally provide arguments that periodic orbits and strange attractors cannot coexist with equilibria. As examples, we show how to solve the prime factorization and the search version of the NP-complete subset-sum problem. Since DMMs map integers into integers, they are robust against noise and hence scalable. We finally discuss the implications of the DMM realization through SOLCs to the NP = P question related to constraints of poly-resources resolvability.

  12. Clinical Relevance of IgE to Profilin and/or Polcalcin in Pollen-Sensitized Patients.

    PubMed

    San Nicoló, Marion; Braun, Thomas; Eder, Katharina; Berghaus, Alexander; Gröger, Moritz

    2016-01-01

    Component-resolved diagnostics is gaining importance in allergy diagnostics. Allergen extracts contain components with different rates of prevalence and clinical relevance, which can be subdivided at molecular level into major and minor allergens. Clinical complaints are usually triggered by major allergens, while the role of sensitization to the panallergens profilin and polcalcin still remains unclear. Eighty-six patients from southern Bavaria with sensitization to the panallergens profilin (Bet v 2/Phl p 12) and/or polcalcin (Bet v 4/Phl p 7) were examined in regard to their sensitization to the 4 main botanic denominations Betulaceae, Oleaceae, Poaceae and Asteraceae by skin prick test and measurement of specific immunoglobulin E antibodies to natural allergen extracts as well as major allergen components rPhl p 1/5, rBet v 1, rOle e 1 and nArt v 1. Sensitization was rated as clinically relevant or irrelevant depending on anamnesis or intranasal allergen challenge. Regarding the 4 botanic denominations, there was no significant difference in the incidence of sensitization to the panallergens profilin, polcalcin or both. The sensitization pattern does not alter when subdividing the cohort into clinically relevant and silent sensitization. We did not find clinically symptomatic sensitization to panallergens without cosensitization to a major allergen. Our results suggest that sole sensitization to panallergens seems to have no clinical relevance in allergic rhinoconjunctivitis. Clinical complaints seem to be triggered manly by major allergens. Thus, component-resolved allergy diagnostics is crucial in the diagnosis and treatment of polysensitized patients. © 2016 S. Karger AG, Basel.

  13. MSLICE Sequencing

    NASA Technical Reports Server (NTRS)

    Crockett, Thomas M.; Joswig, Joseph C.; Shams, Khawaja S.; Norris, Jeffrey S.; Morris, John R.

    2011-01-01

    MSLICE Sequencing is a graphical tool for writing sequences and integrating them into RML files, as well as for producing SCMF files for uplink. When operated in a testbed environment, it also supports uplinking these SCMF files to the testbed via Chill. This software features a free-form textural sequence editor featuring syntax coloring, automatic content assistance (including command and argument completion proposals), complete with types, value ranges, unites, and descriptions from the command dictionary that appear as they are typed. The sequence editor also has a "field mode" that allows tabbing between arguments and displays type/range/units/description for each argument as it is edited. Color-coded error and warning annotations on problematic tokens are included, as well as indications of problems that are not visible in the current scroll range. "Quick Fix" suggestions are made for resolving problems, and all the features afforded by modern source editors are also included such as copy/cut/paste, undo/redo, and a sophisticated find-and-replace system optionally using regular expressions. The software offers a full XML editor for RML files, which features syntax coloring, content assistance and problem annotations as above. There is a form-based, "detail view" that allows structured editing of command arguments and sequence parameters when preferred. The "project view" shows the user s "workspace" as a tree of "resources" (projects, folders, and files) that can subsequently be opened in editors by double-clicking. Files can be added, deleted, dragged-dropped/copied-pasted between folders or projects, and these operations are undoable and redoable. A "problems view" contains a tabular list of all problems in the current workspace. Double-clicking on any row in the table opens an editor for the appropriate sequence, scrolling to the specific line with the problem, and highlighting the problematic characters. From there, one can invoke "quick fix" as described above to resolve the issue. Once resolved, saving the file causes the problem to be removed from the problem view.

  14. Optimal MRI sequence for identifying occlusion location in acute stroke: which value of time-resolved contrast-enhanced MRA?

    PubMed

    Le Bras, A; Raoult, H; Ferré, J-C; Ronzière, T; Gauvrit, J-Y

    2015-06-01

    Identifying occlusion location is crucial for determining the optimal therapeutic strategy during the acute phase of ischemic stroke. The purpose of this study was to assess the diagnostic efficacy of MR imaging, including conventional sequences plus time-resolved contrast-enhanced MRA in comparison with DSA for identifying arterial occlusion location. Thirty-two patients with 34 occlusion levels referred for thrombectomy during acute cerebral stroke events were consecutively included from August 2010 to December 2012. Before thrombectomy, we performed 3T MR imaging, including conventional 3D-TOF and gradient-echo T2 sequences, along with time-resolved contrast-enhanced MRA of the extra- and intracranial arteries. The 3D-TOF, gradient-echo T2, and time-resolved contrast-enhanced MRA results were consensually assessed by 2 neuroradiologists and compared with prethrombectomy DSA results in terms of occlusion location. The Wilcoxon test was used for statistical analysis to compare MR imaging sequences with DSA, and the κ coefficient was used to determine intermodality agreement. The occlusion level on the 3D-TOF and gradient-echo T2 images differed significantly from that of DSA (P < .001 and P = .002, respectively), while no significant difference was observed between DSA and time-resolved contrast-enhanced MRA (P = .125). κ coefficients for intermodality agreement with DSA (95% CI, percentage agreement) were 0.43 (0.3%-0.6; 62%), 0.32 (0.2%-0.5; 56%), and 0.81 (0.6%-1.0; 88%) for 3D-TOF, gradient-echo T2, and time-resolved contrast-enhanced MRA, respectively. The time-resolved contrast-enhanced MRA sequence proved reliable for identifying occlusion location in acute stroke with performance superior to that of 3D-TOF and gradient-echo T2 sequences. © 2015 by American Journal of Neuroradiology.

  15. Seventh international conference on time-resolved vibrational spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyer, R.B.; Martinez, M.A.D.; Shreve, A.

    1997-04-01

    The International Conference on Time-Resolved Vibrational Spectroscopy (TRVS) is widely recognized as the major international forum for the discussion of advances in this rapidly growing field. The 1995 conference was the seventh in a series that began at Lake Placid, New York, 1982. Santa Fe, New Mexico, was the site of the Seventh International Conference on Time-Resolved Vibrational Spectroscopy, held from June 11 to 16, 1995. TRVS-7 was attended by 157 participants from 16 countries and 85 institutions, and research ranging across the full breadth of the field of time-resolved vibrational spectroscopy was presented. Advances in both experimental capabilities formore » time-resolved vibrational measurements and in theoretical descriptions of time-resolved vibrational methods continue to occur, and several sessions of the conference were devoted to discussion of these advances and the associated new directions in TRVS. Continuing the interdisciplinary tradition of the TRVS meetings, applications of time-resolved vibrational methods to problems in physics, biology, materials science, and chemistry comprised a large portion of the papers presented at the conference.« less

  16. Hablando Con Maestros Guia para Padres para Resolver Problemas Con La Escuela = Talking With Teachers: A Problem-Solving Handbook for Parents.

    ERIC Educational Resources Information Center

    Mata, Roberto L.

    Designed to help parents communicate with teachers about the school problems of their children, the handbook provides strategies which can guide parents to collect accurate information about a problem and to use it to initiate an open exchange with the teacher. The strategies can be used whether parents are becoming aware of a problem or have been…

  17. ROC curves in clinical chemistry: uses, misuses, and possible solutions.

    PubMed

    Obuchowski, Nancy A; Lieber, Michael L; Wians, Frank H

    2004-07-01

    ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas >/=0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.

  18. Results From the New NIF Gated LEH imager

    NASA Astrophysics Data System (ADS)

    Chen, Hui; Amendt, P.; Barrios, M.; Bradley, D.; Casey, D.; Hinkel, D.; Berzak Hopkins, L.; Kilkenny, J.; Kritcher, A.; Landen, O.; Jones, O.; Ma, T.; Milovich, J.; Michel, P.; Moody, J.; Ralph, J.; Pak, A.; Palmer, N.; Schneider, M.

    2016-10-01

    A novel ns-gated Laser Entrance Hole (G-LEH) diagnostic has been successfully implemented at the National Ignition Facility (NIF). This diagnostic has successfully acquired images from various experimental campaigns, providing critical information for inertial confinement fusion experiments. The G-LEH diagnostic which takes time-resolved gated images along a single line-of-sight, incorporates a high-speed multi-frame CMOS x-ray imager developed by Sandia National Laboratories into the existing Static X-ray Imager diagnostic at NIF. It is capable of capturing two laser-entrance-hole images per shot on its 1024x448 pixel photo-detector array, with integration times as short as 2 ns per frame. The results that will be presented include the size of the laser entrance hole vs. time, the growth of the laser-heated gold plasma bubble, the change in brightness of inner beam spots due to time-varying cross beam energy transfer, and plasma instability growth near the hohlraum wall. This work was performed under the auspices of the U.S. Department of Energy by LLNS, LLC, under Contract No. DE-AC52- 07NA27344.

  19. The five-year diagnostic utility of "diagnostic orphans" for alcohol use disorders in a national sample of young adults.

    PubMed

    Harford, Thomas C; Yi, Hsiao-Ye; Grant, Bridget F

    2010-05-01

    This study was conducted to assess the association of "diagnostic orphans" at baseline and subsequent development of Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) alcohol use disorders (AUDs) 5 years later. A sample of 8,534 respondents was drawn from the National Longitudinal Survey of Youth for the years 1989 and 1994. Diagnostic orphans were defined as respondents who met one or two alcohol dependence symptom criteria but did not meet the criteria for a diagnosis of alcohol abuse or dependence. Using multinomial logistic regression analysis, 1994 assessments of DSM-IV AUD were regressed on 1989 baseline assessments of diagnostic orphan status and DSM-IV AUD. In addition to demographic characteristics, other background variables included heavy episodic drinking at baseline and early problem behaviors (antisocial behaviors, illicit substance use, and age at onset of alcohol use). Findings from this 5-year prospective study indicate that diagnostic orphan status at baseline was predictive of DSM-IV AUD at follow-up. These associations remained significant when other early behavioral problems were included in the models. The present findings have important diagnostic implications for the proposed DSM-V, particularly for a dimensional diagnosis incorporating less severe forms of alcohol dependence.

  20. EPs welcome new focus on reducing diagnostic errors.

    PubMed

    2015-12-01

    Emergency medicine leaders welcome a major new report from the Institute of Medicine (IOM) calling on providers, policy makers, and government agencies to institute changes to reduce the incidence of diagnostic errors. The 369-page report, "Improving Diagnosis in Health Care," states that the rate of diagnostic errors in this country is unacceptably high and offers a long list of recommendations aimed at addressing the problem. These include large, systemic changes that involve improvements in multiple areas, including health information technology (HIT), professional education, teamwork, and payment reform. Further, of particular interest to emergency physicians are recommended changes to the liability system. The authors of the IOM report state that while most people will likely experience a significant diagnostic error in their lifetime, the importance of this problem is under-appreciated. According to conservative estimates, the report says 5% of adults who seek outpatient care each year experience a diagnostic error. The report also notes that research over many decades shows diagnostic errors contribute to roughly 10% of all.deaths. The report says more steps need to be taken to facilitate inter-professional and intra-professional teamwork throughout the diagnostic process. Experts concur with the report's finding that mechanisms need to be developed so that providers receive ongoing feedback on their diagnostic performance.

  1. Diagnostic features of polycystic ovary syndrome in adolescents (review).

    PubMed

    Beltadze, K; Barbakadze, L

    2015-01-01

    The problem of Polycystic Ovary Syndrome (PCOS) is of a special importance due to its connection with not only medical but with psychosocial factors. PCOS is the most common endocrine cause of anovulatory infertility. It is a major factor for the metabolic syndrome, cardiovascular disease, type 2 diabetes mellitus (T2DM). Clinical symptoms of PCOS such as acne, hirsutism, obesity, alopecia represent psychological problem, especially for the adolescents. Many women who have PCOS have the onset of symptoms during adolescence. Early diagnosis and treatment of PCOS are important for preventing of the above mentioned long-term consequences associated with this condition. Adolescent patients often have diagnostic problems because the features of normal puberty are similar with symptoms of PCOS. This article reviews the diagnostic and differential diagnostic characteristics of PCOS in adolescents. In conclusion, consensus statement in adolescent patients is still awaiting. Our data suggest that it may be prudent to define adolescent PCOS according to the Carmina modified Rotterdam criteria. The increase rate of metabolic syndrome in adolescents with PCOS emphasize the importance of regular screening due to the high cardiometabolic disorders risk.

  2. Introducing First-Year Medical Students to Early Diagnostic Hypotheses

    ERIC Educational Resources Information Center

    Taylor, P. J.; And Others

    1978-01-01

    A method of instruction in gynecology is described that encouraged the formulation of early diagnostic hypotheses, an important part of clinical problem-solving. Students were given a set of clinical clues to help them make broad diagnostic hypotheses. Student ability, results, and student perceptions of the course are provided. (Author/LBH)

  3. Teaching Teachers Teaching.

    ERIC Educational Resources Information Center

    Wees, W. R.

    This monograph, designed to stimulate national discussion, pictures "teacher education as it is" by indicating problems as deans and heads of departments see them, and by reporting innovative practices by which various universities are attempting to resolve some problems. The main sources of this information were university calendars,…

  4. Evaluating a Dental Diagnostic Terminology in an Electronic Health Record

    PubMed Central

    White, Joel M.; Kalenderian, Elsbeth; Stark, Paul C.; Ramoni, Rachel L.; Vaderhobli, Ram; Walji, Muhammad F.

    2011-01-01

    Standardized treatment procedure codes and terms are routinely used in dentistry. Utilization of a diagnostic terminology is common in medicine, but there is not a satisfactory or commonly standardized dental diagnostic terminology available at this time. Recent advances in dental informatics have provided an opportunity for inclusion of diagnostic codes and terms as part of treatment planning and documentation in the patient treatment history. This article reports the results of the use of a diagnostic coding system in a large dental school’s predoctoral clinical practice. A list of diagnostic codes and terms, called Z codes, was developed by dental faculty members. The diagnostic codes and terms were implemented into an electronic health record (EHR) for use in a predoctoral dental clinic. The utilization of diagnostic terms was quantified. The validity of Z code entry was evaluated by comparing the diagnostic term entered to the procedure performed, where valid diagnosis-procedure associations were determined by consensus among three calibrated academically based dentists. A total of 115,004 dental procedures were entered into the EHR during the year sampled. Of those, 43,053 were excluded from this analysis because they represent diagnosis or other procedures unrelated to treatments. Among the 71,951 treatment procedures, 27,973 had diagnoses assigned to them with an overall utilization of 38.9 percent. Of the 147 available Z codes, ninety-three were used (63.3 percent). There were 335 unique procedures provided and 2,127 procedure/diagnosis pairs captured in the EHR. Overall, 76.7 percent of the diagnoses entered were valid. We conclude that dental diagnostic terminology can be incorporated within an electronic health record and utilized in an academic clinical environment. Challenges remain in the development of terms and implementation and ease of use that, if resolved, would improve the utilization. PMID:21546594

  5. Usefulness of component resolved analysis of cat allergy in routine clinical practice.

    PubMed

    Eder, Katharina; Becker, Sven; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz

    2016-01-01

    Cat allergy is of great importance, and its prevalence is increasing worldwide. Cat allergens and house dust mite allergens represent the major indoor allergens; however, they are ubiquitous. Cat sensitization and allergy are known risk factors for rhinitis, bronchial hyperreactivity and asthma. Thus, the diagnosis of sensitization to cats is important for any allergist. 70 patients with positive skin prick tests for cats were retrospectively compared regarding their skin prick test results, as well as their specific immunoglobulin E antibody profiles with regard to their responses to the native cat extract, rFel d 1, nFel d 2 and rFel d 4. 35 patients were allergic to cats, as determined by positive anamnesis and/or nasal provocation with cat allergens, and 35 patients exhibited clinically non-relevant sensitization, as indicated by negative anamnesis and/or a negative nasal allergen challenge. Native cat extract serology testing detected 100% of patients who were allergic to cats but missed eight patients who showed sensitization in the skin prick test and did not have allergic symptoms. The median values of the skin prick test, as well as those of the specific immunoglobulin E antibodies against the native cat extract, were significantly higher for allergic patients than for patients with clinically non-relevant sensitization. Component based diagnostic testing to rFel d 1 was not as reliable. Sensitization to nFel d 2 and rFel d 4 was seen only in individual patients. Extract based diagnostic methods for identifying cat allergy and sensitization, such as the skin prick test and native cat extract serology, remain crucial in routine clinical practice. In our study, component based diagnostic testing could not replace these methods with regard to the detection of sensitization to cats and differentiation between allergy and sensitization without clinical relevance. However, component resolved allergy diagnostic tools have individual implications, and future studies may facilitate a better understanding of its use and subsequently may improve the clinical management of allergic patients.

  6. Peripheral Vasculature: High-Temporal- and High-Spatial-Resolution Three-dimensional Contrast-enhanced MR Angiography1

    PubMed Central

    Haider, Clifton R.; Glockner, James F.; Stanson, Anthony W.; Riederer, Stephen J.

    2009-01-01

    Purpose: To prospectively evaluate the feasibility of performing high-spatial-resolution (1-mm isotropic) time-resolved three-dimensional (3D) contrast material–enhanced magnetic resonance (MR) angiography of the peripheral vasculature with Cartesian acquisition with projection-reconstruction–like sampling (CAPR) and eightfold accelerated two-dimensional (2D) sensitivity encoding (SENSE). Materials and Methods: All studies were approved by the institutional review board and were HIPAA compliant; written informed consent was obtained from all participants. There were 13 volunteers (mean age, 41.9; range, 27–53 years). The CAPR sequence was adapted to provide 1-mm isotropic spatial resolution and a 5-second frame time. Use of different receiver coil element sizes for those placed on the anterior-to-posterior versus left-to-right sides of the field of view reduced signal-to-noise ratio loss due to acceleration. Results from eight volunteers were rated independently by two radiologists according to prominence of artifact, arterial to venous separation, vessel sharpness, continuity of arterial signal intensity in major arteries (anterior and posterior tibial, peroneal), demarcation of origin of major arteries, and overall diagnostic image quality. MR angiographic results in two patients with peripheral vascular disease were compared with their results at computed tomographic angiography. Results: The sequence exhibited no image artifact adversely affecting diagnostic image quality. Temporal resolution was evaluated to be sufficient in all cases, even with known rapid arterial to venous transit. The vessels were graded to have excellent sharpness, continuity, and demarcation of the origins of the major arteries. Distal muscular branches and the communicating and perforating arteries were routinely seen. Excellent diagnostic quality rating was given for 15 (94%) of 16 evaluations. Conclusion: The feasibility of performing high-diagnostic-quality time-resolved 3D contrast-enhanced MR angiography of the peripheral vasculature by using CAPR and eightfold accelerated 2D SENSE has been demonstrated. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081744/-/DC1 PMID:19789238

  7. Lattice Commissioning Stretgy Simulation for the B Factory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, M.; Whittum, D.; Yan, Y.

    2011-08-26

    To prepare for the PEP-II turn on, we have studied one commissioning strategy with simulated lattice errors. Features such as difference and absolute orbit analysis and correction are discussed. To prepare for the commissioning of the PEP-II injection line and high energy ring (HER), we have developed a system for on-line orbit analysis by merging two existing codes: LEGO and RESOLVE. With the LEGO-RESOLVE system, we can study the problem of finding quadrupole alignment and beam position (BPM) offset errors with simulated data. We have increased the speed and versatility of the orbit analysis process by using a command filemore » written in a script language designed specifically for RESOLVE. In addition, we have interfaced the LEGO-RESOLVE system to the control system of the B-Factory. In this paper, we describe online analysis features of the LEGO-RESOLVE system and present examples of practical applications.« less

  8. Novel Indocyanine Green-Phytate Colloid Technique for Sentinel Node Detection in Head and Neck: Mouse Study.

    PubMed

    Araki, Koji; Mizokami, Daisuke; Tomifuji, Masayuki; Yamashita, Taku; Ohnuki, Kazunobu; Umeda, Izumi O; Fujii, Hirofumi; Kosuda, Shigeru; Shiotani, Akihiro

    2014-08-01

    Sentinel node navigation surgery using real-time, near-infrared imaging with indocyanine green is becoming popular by allowing head and neck surgeons to avoid unnecessary neck dissection. The major drawback of this method is its quick migration through the lymphatics, limiting the diagnostic time window and undesirable detection of downstream nodes. We resolved this problem by mixing indocyanine green (ICG) with phytate colloid to retard its migration and demonstrated its feasibility in a nude mouse study. Experimental prospective animal study. Animal laboratory. Indocyanine green at 3 concentrations was tested to determine the optimal concentration for sentinel lymph node detection in a mouse model. Effect of indocyanine green with phytate colloid mixture solutions was also analyzed. Indocyanine green or mixture solution at different mixing ratios were injected into the tongue of nude mice and near-infrared fluorescence images were captured sequentially for up to 48 hours. The brightness of fluorescence in the sentinel lymph node and lymph nodes further downstream were assessed. Indocyanine green concentration >50 μg/mL did not improve sentinel lymph node detection. The addition of phytate colloid to indocyanine green extended the period when sentinel lymph node was detectable. Second echelon lymph nodes were not imaged in mice injected with the mixture, while these were visualized in mice injected with indocyanine green alone. This novel technique of ICG-phytate colloid mixture allows prolonged diagnostic time window, prevention of downstream subsequent nodes detection, and improved accuracy for the detection of true sentinel lymph nodes. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  9. Electron density measurements for plasma adaptive optics

    NASA Astrophysics Data System (ADS)

    Neiswander, Brian W.

    Over the past 40 years, there has been growing interest in both laser communications and directed energy weapons that operate from moving aircraft. As a laser beam propagates from an aircraft in flight, it passes through boundary layers, turbulence, and shear layers in the near-region of the aircraft. These fluid instabilities cause strong density gradients which adversely affect the transmission of laser energy to a target. Adaptive optics provides corrective measures for this problem but current technology cannot respond quickly enough to be useful for high speed flight conditions. This research investigated the use of plasma as a medium for adaptive optics for aero-optics applications. When a laser beam passes through plasma, its phase is shifted proportionally to the electron density and gas heating within the plasma. As a result, plasma can be utilized as a dynamically controllable optical medium. Experiments were carried out using a cylindrical dielectric barrier discharge plasma chamber which generated a sub-atmospheric pressure, low-temperature plasma. An electrostatic model of this design was developed and revealed an important design constraint relating to the geometry of the chamber. Optical diagnostic techniques were used to characterize the plasma discharge. Single-wavelength interferometric experiments were performed and demonstrated up to 1.5 microns of optical path difference (OPD) in a 633 nm laser beam. Dual-wavelength interferometry was used to obtain time-resolved profiles of the plasma electron density and gas heating inside the plasma chamber. Furthermore, a new multi-wavelength infrared diagnostic technique was developed and proof-of-concept simulations were conducted to demonstrate the system's capabilities.

  10. Problem Definition and Solution Strategies in Dental Practice. Final Report, September 19, 1979-October 31, 1980.

    ERIC Educational Resources Information Center

    Dane, J. K.; And Others

    A study was conducted to identify and analyze clinical and nonclinical problems commonly met by dental practitioners, and the strategies and resources used by dentists to resolve these problems. Nearly 50 individuals in dentistry and related areas were organized into a steering committee and four task groups. Data were gathered through meetings of…

  11. Methodological Issues in the Measurement of Non-Random Family Problem Solving Interaction.

    ERIC Educational Resources Information Center

    Kieren, Dianne K.; Hurlbut, Nancy L.

    The family is an obvious group for whom problem solving effectiveness holds importance. Problem solving interaction refers to the manner in which the behavior of family members is organized to resolve situations in which there is an unachieved but attainable goal, and the means to overcoming the barriers to achieving the goal are not apparent, but…

  12. On the Complexity of Duplication-Transfer-Loss Reconciliation with Non-Binary Gene Trees.

    PubMed

    Kordi, Misagh; Bansal, Mukul S

    2017-01-01

    Duplication-Transfer-Loss (DTL) reconciliation has emerged as a powerful technique for studying gene family evolution in the presence of horizontal gene transfer. DTL reconciliation takes as input a gene family phylogeny and the corresponding species phylogeny, and reconciles the two by postulating speciation, gene duplication, horizontal gene transfer, and gene loss events. Efficient algorithms exist for finding optimal DTL reconciliations when the gene tree is binary. However, gene trees are frequently non-binary. With such non-binary gene trees, the reconciliation problem seeks to find a binary resolution of the gene tree that minimizes the reconciliation cost. Given the prevalence of non-binary gene trees, many efficient algorithms have been developed for this problem in the context of the simpler Duplication-Loss (DL) reconciliation model. Yet, no efficient algorithms exist for DTL reconciliation with non-binary gene trees and the complexity of the problem remains unknown. In this work, we resolve this open question by showing that the problem is, in fact, NP-hard. Our reduction applies to both the dated and undated formulations of DTL reconciliation. By resolving this long-standing open problem, this work will spur the development of both exact and heuristic algorithms for this important problem.

  13. ISM DUST GRAINS AND N-BAND SPECTRAL VARIABILITY IN THE SPATIALLY RESOLVED SUBARCSECOND BINARY UY Aur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skemer, Andrew J.; Close, Laird M.; Hinz, Philip M.

    2010-03-10

    The 10 {mu}m silicate feature is an essential diagnostic of dust-grain growth and planet formation in young circumstellar disks. The Spitzer Space Telescope has revolutionized the study of this feature, but due to its small (85 cm) aperture, it cannot spatially resolve small/medium-separation binaries ({approx}<3''; {approx}< 420 AU) at the distances of the nearest star-forming regions ({approx}140 pc). Large, 6-10 m ground-based telescopes with mid-infrared instruments can resolve these systems. In this paper, we spatially resolve the 0.''88 binary, UY Aur, with MMTAO/BLINC-MIRAC4 mid-infrared spectroscopy. We then compare our spectra to Spitzer/IRS (unresolved) spectroscopy, and resolved images from IRTF/MIRAC2, Keck/OSCIR,more » and Gemini/Michelle, which were taken over the past decade. We find that UY Aur A has extremely pristine, interstellar medium (ISM)-like grains and that UY Aur B has an unusually shaped silicate feature, which is probably the result of blended emission and absorption from foreground extinction in its disk. We also find evidence for variability in both UY Aur A and UY Aur B by comparing synthetic photometry from our spectra with resolved imaging from previous epochs. The photometric variability of UY Aur A could be an indication that the silicate emission itself is variable, as was recently found in EX Lupi. Otherwise, the thermal continuum is variable, and either the ISM-like dust has never evolved, or it is being replenished, perhaps by UY Aur's circumbinary disk.« less

  14. Macroclumping as solution of the discrepancy between Hα and P v mass loss diagnostics for O-type stars

    NASA Astrophysics Data System (ADS)

    Šurlan, B.; Hamann, W.-R.; Aret, A.; Kubát, J.; Oskinova, L. M.; Torres, A. F.

    2013-11-01

    Context. Recent studies of O-type stars have demonstrated that discrepant mass-loss rates are obtained when different diagnostic methods are employed. Fitting the unsaturated UV resonance lines (e.g., P v) gives drastically lower values than obtained from the Hα emission. Wind inhomogeneity (so-called "clumping") may be the main cause of this discrepancy. Aims: In a previous paper, we presented 3D Monte-Carlo calculations for the formation of scattering lines in a clumped stellar wind. In the present paper we select five O-type supergiants (from O4 to O7) and test whether the reported discrepancies can be resolved this way. Methods: In the first step, the analyses started with simulating the observed spectra with Potsdam Wolf-Rayet (PoWR) non-LTE model atmospheres. The mass-loss rates are adjusted to fit to the observed Hα emission lines best. For the unsaturated UV resonance lines (i.e., P v) we then applied our 3D Monte-Carlo code, which can account for wind clumps of any optical depths ("macroclumping"), a non-void interclump medium, and a velocity dispersion inside the clumps. The ionization stratifications and underlying photospheric spectra were adopted from the PoWR models. The properties of the wind clumps were constrained by fitting the observed resonance line profiles. Results: Our results show that with the mass-loss rates that fit Hα (and other Balmer and He ii lines), the UV resonance lines (especially the unsaturated doublet of P v) can also be reproduced with no problem when macroclumping is taken into account. There is no need to artificially reduce the mass-loss rates or to assume a subsolar phosphorus abundance or an extremely high clumping factor, unlike what was claimed by other authors. These consistent mass-loss rates are lower by a factor of 1.3 to 2.6, compared to the mass-loss rate recipe from Vink et al. Conclusions: Macroclumping resolves the previously reported discrepancy between Hα and P v mass-loss diagnostics. Based on observations collected with the Perek 2-m Telescope of the Ondřejov Observatory, Czech Republic.Based on observations taken at the Complejo Astronómico El Leoncito (CASLEO), operated under an agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina, the Secretaría de Ciencia y Tecnología de la Nación, and the National Universities of La Plata, Córdoba, and San Juan.Appendix A is available in electronic form at http://www.aanda.org

  15. Expert Systems and Diagnostic Monitors in Psychiatry

    PubMed Central

    Gelernter, David; Gelernter, Joel

    1984-01-01

    We argue that existing expert systems for medical diagnosis have not satisfactorily addressed an important problem: how are such systems to be integrated into the clinical environment? This problem should be addressed before and not after a working system is developed, because its solution might well determine important aspects of the ultimate system structure. We propose as one solution the online diagnostic monitor, which is a diagnostic expert system designed for interactive use by a clinican during the course of a patient interview. The exchange between a diagnostic monitor and its clinican user is guided by the user, not the system, and the monitor functions as a passive advisor rather than an active decision-maker. We discuss why a system of this sort might be particularly well-suited to psychiatric diagnosis, and describe preliminary work on an experimental prototype.

  16. Diagnostic orphans: comparing self-report lifetime course to groups with DSM-IV alcohol abuse and dependence.

    PubMed

    McBride, Orla; Adamson, Gary; Bunting, Brendan; McCann, Siobhan

    2009-01-01

    Research has highlighted the significant alcohol symptoms and mental health problems experienced by diagnostic orphans - individuals who experience 1-2 criteria of DSM-IV alcohol dependence but do not meet the criteria for a DSM-IV alcohol use disorder. This study used a sub-sample (n=34827) from the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC), and formed mutually exclusive groups to compare the self-report retrospective course of diagnostic orphans to individuals with DSM-IV abuse and dependence. Multinomial logistic regressions were conducted to examine the associations between the groups and a range of demographic and clinical variables. Collectively, the findings demonstrate that diagnostic orphans shared similar characteristics to the abuse and dependence groups, but appeared to experience specific comorbid mental health problems. Orphan status has the potential to be a persistent condition and may result in significant dysfunction. In conclusion, diagnostic orphans represent a distinct group that may benefit from cost-effective treatment or intervention, designed to prevent the escalation of alcohol symptoms.

  17. [Nodular toxoplasmosis as a diagnostic and therapeutic problem].

    PubMed

    Zaorski, P; Kozłowski, J

    1999-01-01

    Enlargement of lymph nodes of the neck, slightly elevated body temperature and discomfort are symptoms characteristic of many illnesses. One of these can be toxoplasmosis. Because the rarity of its occurrence, sometimes toxoplasmosis may be last to be recognized. In many cases absence of specific additional examination guidelines can contribute to several problems with correct diagnosis. At the present time, the most reliable sample analysis methods are the examination of levels of antibodies IgG and IgM, and the histopathological verification. The authors also indicate that varying therapeutic effects using prophilactic treatment and insufficient additional examination could lead to diagnostic problems.

  18. The point-spread function measure of resolution for the 3-D electrical resistivity experiment

    NASA Astrophysics Data System (ADS)

    Oldenborger, Greg A.; Routh, Partha S.

    2009-02-01

    The solution appraisal component of the inverse problem involves investigation of the relationship between our estimated model and the actual model. However, full appraisal is difficult for large 3-D problems such as electrical resistivity tomography (ERT). We tackle the appraisal problem for 3-D ERT via the point-spread functions (PSFs) of the linearized resolution matrix. The PSFs represent the impulse response of the inverse solution and quantify our parameter-specific resolving capability. We implement an iterative least-squares solution of the PSF for the ERT experiment, using on-the-fly calculation of the sensitivity via an adjoint integral equation with stored Green's functions and subgrid reduction. For a synthetic example, analysis of individual PSFs demonstrates the truly 3-D character of the resolution. The PSFs for the ERT experiment are Gaussian-like in shape, with directional asymmetry and significant off-diagonal features. Computation of attributes representative of the blurring and localization of the PSF reveal significant spatial dependence of the resolution with some correlation to the electrode infrastructure. Application to a time-lapse ground-water monitoring experiment demonstrates the utility of the PSF for assessing feature discrimination, predicting artefacts and identifying model dependence of resolution. For a judicious selection of model parameters, we analyse the PSFs and their attributes to quantify the case-specific localized resolving capability and its variability over regions of interest. We observe approximate interborehole resolving capability of less than 1-1.5m in the vertical direction and less than 1-2.5m in the horizontal direction. Resolving capability deteriorates significantly outside the electrode infrastructure.

  19. RESOLVING THE RADON PROBLEM IN CLINTON, NEW JERSEY HOUSES

    EPA Science Inventory

    The paper discusses the resolution of a radon problem in Clinton, New Jersey, where significantly elevated radon concentrations were found in several adjacent houses. The U.S. EPA screened 56 of the houses and selected 10 for demonstration of radon reduction techniques. Each of t...

  20. Searching for Solutions: Supervising Student Employees

    ERIC Educational Resources Information Center

    Comer, Alberta Davis

    2003-01-01

    Lending services units at Indiana State University's Cunningham Memorial Library depend heavily on student employees to fulfill their specific missions. Problems attributed to poor communication and lack of motivation among student employees were causing negative impacts on the units' abilities to function well. To resolve these problems,…

  1. Creativity, Problem Solving, and Solution Set Sightedness: Radically Reformulating BVSR

    ERIC Educational Resources Information Center

    Simonton, Dean Keith

    2012-01-01

    Too often, psychological debates become polarized into dichotomous positions. Such polarization may have occurred with respect to Campbell's (1960) blind variation and selective retention (BVSR) theory of creativity. To resolve this unnecessary controversy, BVSR was radically reformulated with respect to creative problem solving. The reformulation…

  2. DUD Investigation of M69 Electric Detonator

    DTIC Science & Technology

    1978-04-01

    OF CONTENTS I. INTRODUCTION II. BACKGROUND ýII. ANALYSIS OF PROBLEM IV. CORRECTrIE DESIGN REVISION V. DISCUSSION OF RESULTS VI. RECOMMENDATIONS ) VII...analyze and resolve the problem. ii 9 III. ANALYSIS OF PROBLEM A review of the data available at the start of this investigation revealed the...a dud problem. d. Dud analysis of those detonators which failed to fire, showed that the Carbon Bridge had been pulsed electrically and for all

  3. Vers une Meilleure Connaissance des Facons dont les Apprenants de L2 Resolvent Leurs Problemes dans l'Environnement Multimedia (Toward a Better Understanding of the Ways in Which L2 Learners Solve Problems in a Multimedia Environment).

    ERIC Educational Resources Information Center

    Duquette, Lise

    1999-01-01

    Examines the role of metacognition, particularly problem solving strategies, in how second language students learn in a multimedia environment, studying problem solving strategies used by students completing exercises in Mydlarski and Paramskas' program, Vi-Conte. Presents recommendations for training teachers, noting that the flexibility of…

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Partridge Jr, William P.; Choi, Jae-Soon

    By directly resolving spatial and temporal species distributions within operating honeycomb monolith catalysts, spatially resolved capillary inlet mass spectrometry (SpaciMS) provides a uniquely enabling perspective for advancing automotive catalysis. Specifically, the ability to follow the spatiotemporal evolution of reactions throughout the catalyst is a significant advantage over inlet-and-effluent-limited analysis. Intracatalyst resolution elucidates numerous catalyst details including the network and sequence of reactions, clarifying reaction pathways; the relative rates of different reactions and impacts of operating conditions and catalyst state; and reaction dynamics and intermediate species that exist only within the catalyst. These details provide a better understanding of how themore » catalyst functions and have basic and practical benefits; e.g., catalyst system design; strategies for on-road catalyst state assessment, control, and on-board diagnostics; and creating robust and accurate predictive catalyst models. Moreover, such spatiotemporally distributed data provide for critical model assessment, and identification of improvement opportunities that might not be apparent from effluent assessment; i.e., while an incorrectly formulated model may provide correct effluent predictions, one that can accurately predict the spatiotemporal evolution of reactions along the catalyst channels will be more robust, accurate, and reliable. In such ways, intracatalyst diagnostics comprehensively enable improved design and development tools, and faster and lower-cost development of more efficient and durable automotive catalyst systems. Beyond these direct contributions, SpaciMS has spawned and been applied to enable other analytical techniques for resolving transient distributed intracatalyst performance. This chapter focuses on SpaciMS applications and associated catalyst insights and improvements, with specific sections related to lean NOx traps, selective catalytic reduction catalysts, oxidation catalysts, and particulate filters. The objective is to promote broader use and development of intracatalyst analytical methods, and thereby expand the insights resulting from this detailed perspective for advancing automotive catalyst technologies.« less

  5. [The value of high resolution diffusion weighted imaging in differentiating benign and malignant epithelial tumors of parotid gland].

    PubMed

    Wen, B H; Cheng, J L; Zhang, H X; Zhang, Z X; Wang, F F; Xue, K K

    2018-05-08

    Objective: To investigate the diagnostic value of RESOLVE DWI in the evaluation of benign and malignant epithelial tumors of parotid gland. Methods: A total of 106 patients in the First Affiliated Hospital of Zhengzhou University with epithelial tumors of parotid gland confirmed by pathology from July 2015 to October 2017 were retrospectively analyzed. All patients underwent preoperative routine MRI and RESOLVE DWI, the ADC average values were calculated, t test were used to compare the ADC values of benign and malignant epithelial tumors of parotid gland. Diagnostic performance of ADC value was compared using receiver operating characteristic (ROC)curves. Results: All lesions were solitary, including 69 benign epithelial tumors and 37 malignant epithelial tumors. The mean ADC values of pleomorphic adenoma and basal cell adenoma, adenolymphoma and malignant epithelial tumors were (1.47±0.16)×10(-3) mm(2)/s, (0.83±0.19)×10(-3) mm(2)/s and(1.14±0.14)×10(-3) mm(2)/s, the mean ADC value of adenolymphoma lower than the rest of the two groups, there were statistically significant differences among them ( P <0.05). Using 0.94×10(-3) mm(2)/s≤ADC value≤1.28×10(-3)mm(2)/s as the critical value for diagnosing malignant epithelial tumors of parotid gland and comparing with pathological results, the result obtained had a sensitivity of 81.1%, specificity of 88.9%. ADC value had high correlations compared with pathological results, kappa value was 0.600. Conclusion: RESOLVE DWI can be applied in differential diagnosis between benign and malignant epithelial tumors of parotid gland.

  6. Photolithography diagnostic expert systems: a systematic approach to problem solving in a wafer fabrication facility

    NASA Astrophysics Data System (ADS)

    Weatherwax Scott, Caroline; Tsareff, Christopher R.

    1990-06-01

    One of the main goals of process engineering in the semiconductor industry is to improve wafer fabrication productivity and throughput. Engineers must work continuously toward this goal in addition to performing sustaining and development tasks. To accomplish these objectives, managers must make efficient use of engineering resources. One of the tools being used to improve efficiency is the diagnostic expert system. Expert systems are knowledge based computer programs designed to lead the user through the analysis and solution of a problem. Several photolithography diagnostic expert systems have been implemented at the Hughes Technology Center to provide a systematic approach to process problem solving. This systematic approach was achieved by documenting cause and effect analyses for a wide variety of processing problems. This knowledge was organized in the form of IF-THEN rules, a common structure for knowledge representation in expert system technology. These rules form the knowledge base of the expert system which is stored in the computer. The systems also include the problem solving methodology used by the expert when addressing a problem in his area of expertise. Operators now use the expert systems to solve many process problems without engineering assistance. The systems also facilitate the collection of appropriate data to assist engineering in solving unanticipated problems. Currently, several expert systems have been implemented to cover all aspects of the photolithography process. The systems, which have been in use for over a year, include wafer surface preparation (HMDS), photoresist coat and softbake, align and expose on a wafer stepper, and develop inspection. These systems are part of a plan to implement an expert system diagnostic environment throughout the wafer fabrication facility. In this paper, the systems' construction is described, including knowledge acquisition, rule construction, knowledge refinement, testing, and evaluation. The roles played by the process engineering expert and the knowledge engineer are discussed. The features of the systems are shown, particularly the interactive quality of the consultations and the ease of system use.

  7. The Zero to Three Diagnostic System: A Framework for Considering Emotional and Behavioral Problems in Young Children

    ERIC Educational Resources Information Center

    Evangelista, Nancy; McLellan, Mary J.

    2004-01-01

    The expansion of early childhood services has brought increasing recognition of the need to address mental health disorders in young children. The transactional perspective of developmental psychopathology is the basis for review of diagnostic frameworks for young children. The Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) is…

  8. Small Body GN&C Research Report: A Robust Model Predictive Control Algorithm with Guaranteed Resolvability

    NASA Technical Reports Server (NTRS)

    Acikmese, Behcet A.; Carson, John M., III

    2005-01-01

    A robustly stabilizing MPC (model predictive control) algorithm for uncertain nonlinear systems is developed that guarantees the resolvability of the associated finite-horizon optimal control problem in a receding-horizon implementation. The control consists of two components; (i) feedforward, and (ii) feedback part. Feed-forward control is obtained by online solution of a finite-horizon optimal control problem for the nominal system dynamics. The feedback control policy is designed off-line based on a bound on the uncertainty in the system model. The entire controller is shown to be robustly stabilizing with a region of attraction composed of initial states for which the finite-horizon optimal control problem is feasible. The controller design for this algorithm is demonstrated on a class of systems with uncertain nonlinear terms that have norm-bounded derivatives, and derivatives in polytopes. An illustrative numerical example is also provided.

  9. Exploring natural supersymmetry at the LHC

    NASA Astrophysics Data System (ADS)

    Nasir, Fariha

    This dissertation demonstrates how a variety of supersymmetric grand unified theories can resolve the little hierarchy problem in the minimal supersymmetric standard model and also explain the observed deviation in the anomalous magnetic moment of the muon. The origin of the little hierarchy problem lies in the sensitive manner in which the Z boson mass depends on parameters that can be much larger than its mass. Large values of these parameters imply that a large fine tuning is required to obtain the correct Z boson mass. With large fine tuning supersymmetry appears unnatural which is why models that attempt to resolve this problem are referred to as natural SUSY models. We show that a possible way to exhibit natural supersymmetry is to assume non-universal gauginos in a class of supersymmetric grand unified models. We further show that considering non-universal gauginos in a class of supersymmetric models can help explain the apparent anomaly in the magnetic moment of the muon.

  10. A modified active appearance model based on an adaptive artificial bee colony.

    PubMed

    Abdulameer, Mohammed Hasan; Sheikh Abdullah, Siti Norul Huda; Othman, Zulaiha Ali

    2014-01-01

    Active appearance model (AAM) is one of the most popular model-based approaches that have been extensively used to extract features by highly accurate modeling of human faces under various physical and environmental circumstances. However, in such active appearance model, fitting the model with original image is a challenging task. State of the art shows that optimization method is applicable to resolve this problem. However, another common problem is applying optimization. Hence, in this paper we propose an AAM based face recognition technique, which is capable of resolving the fitting problem of AAM by introducing a new adaptive ABC algorithm. The adaptation increases the efficiency of fitting as against the conventional ABC algorithm. We have used three datasets: CASIA dataset, property 2.5D face dataset, and UBIRIS v1 images dataset in our experiments. The results have revealed that the proposed face recognition technique has performed effectively, in terms of accuracy of face recognition.

  11. Research on Optimization of Pooling System and Its Application in Drug Supply Chain Based on Big Data Analysis

    PubMed Central

    2017-01-01

    Reform of drug procurement is being extensively implemented and expanded in China, especially in today's big data environment. However, the pattern of supply mode innovation lags behind procurement improvement. Problems in financial strain and supply break frequently occur, which affect the stability of drug supply. Drug Pooling System is proposed and applied in a few pilot cities to resolve these problems. From the perspective of supply chain, this study analyzes the process of setting important parameters and sets out the tasks of involved parties in a pooling system according to the issues identified in the pilot run. The approach is based on big data analysis and simulation using system dynamic theory and modeling of Vensim software to optimize system performance. This study proposes a theoretical framework to resolve problems and attempts to provide a valuable reference for future application of pooling systems. PMID:28293258

  12. Analysis of junior high school students' difficulty in resolving rectangular conceptual problems

    NASA Astrophysics Data System (ADS)

    Utami, Aliksia Kristiana Dwi; Mardiyana, Pramudya, Ikrar

    2017-08-01

    Geometry is one part of the mathematics that must be learned in school and it has important effects on the development of creative thinking skills of learners, but in fact, there are some difficulties experienced by the students. This research focuses on analysis difficulty in resolving rectangular conceptual problems among junior high school students in every creative thinking skills level. This research used a descriptive method aimed to identify the difficulties and cause of the difficulties experienced by five students. The difficulties are associated with rectangular shapes and related problems. Data collection was done based on students' work through test, interview, and observations. The result revealed that student' difficulties in understanding the rectangular concept can be found at every creative thinking skills level. The difficulties are identifying the objects rectangular in the daily life except for a rectangle and square, analyzing the properties of rectangular shapes, and seeing the interrelationships between figures.

  13. A methodology to enhance electromagnetic compatibility in joint military operations

    NASA Astrophysics Data System (ADS)

    Buckellew, William R.

    The development and validation of an improved methodology to identify, characterize, and prioritize potential joint EMI (electromagnetic interference) interactions and identify and develop solutions to reduce the effects of the interference are discussed. The methodology identifies potential EMI problems using results from field operations, historical data bases, and analytical modeling. Operational expertise, engineering analysis, and testing are used to characterize and prioritize the potential EMI problems. Results can be used to resolve potential EMI during the development and acquisition of new systems and to develop engineering fixes and operational workarounds for systems already employed. The analytic modeling portion of the methodology is a predictive process that uses progressive refinement of the analysis and the operational electronic environment to eliminate noninterfering equipment pairs, defer further analysis on pairs lacking operational significance, and resolve the remaining EMI problems. Tests are conducted on equipment pairs to ensure that the analytical models provide a realistic description of the predicted interference.

  14. Numerical Analysis of Coolant Flow and Heat Transfer in ITER Diagnostic First Wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khodak, A.; Loesser, G.; Zhai, Y.

    2015-07-24

    We performed numerical simulations of the ITER Diagnostic First Wall (DFW) using ANSYS workbench. During operation DFW will include solid main body as well as liquid coolant. Thus thermal and hydraulic analysis of the DFW was performed using conjugated heat transfer approach, in which heat transfer was resolved in both solid and liquid parts, and simultaneously fluid dynamics analysis was performed only in the liquid part. This approach includes interface between solid and liquid part of the systemAnalysis was performed using ANSYS CFX software. CFX software allows solution of heat transfer equations in solid and liquid part, and solution ofmore » the flow equations in the liquid part. Coolant flow in the DFW was assumed turbulent and was resolved using Reynolds averaged Navier-Stokes equations with Shear Stress Transport turbulence model. Meshing was performed using CFX method available within ANSYS. The data cloud for thermal loading consisting of volumetric heating and surface heating was imported into CFX Volumetric heating source was generated using Attila software. Surface heating was obtained using radiation heat transfer analysis. Our results allowed us to identify areas of excessive heating. Proposals for cooling channel relocation were made. Additional suggestions were made to improve hydraulic performance of the cooling system.« less

  15. Understanding the Effect of Gas Dynamics in Plasma Gun Performance for Simulating Fusion Wall Response to Disruption Events

    NASA Astrophysics Data System (ADS)

    Riedel, Will; Underwood, Thomas; Righetti, Fabio; Cappelli, Mark

    2017-10-01

    In this work, the suitability of a pulsed coaxial plasma accelerator to simulate the interaction of edge-localized modes with plasma first wall materials is investigated. Experimental measurements derived from a suite of diagnostics are presented that focus on both the properties of the plasma flow and the manner in which such jets couple with material interfaces. Specific emphasis is placed on quantifying the variation in these properties using tungsten tokens exposed to the plasma plume as the gun volume is progressively filled with more neutral gas. These results are mapped to the operational dynamics of the gun via a time-resolved Schlieren cinematic visualization of the density gradient within the flow. Resulting videos indicate the existence of two distinct modes with vastly different characteristic timescales, spatial evolution, and plasma properties. Time resolved quantification of the associated plasma heat flux for both modes, including a range spanning 150 MW m-2 - 10 GW m-2, is presented using both a fast thermocouple gauge and an IR camera. Both diagnostics in conjunction with a heat transfer model provide an accurate description of the energy transfer dynamics and operational characteristics of plasma guns. This work is supported by the U.S. Department of Energy Stewardship Science Academic Program.

  16. Novel tissue phantom for testing a dual-modality diagnostic system: time-resolved fluorescence spectroscopy and high frequency ultrasound

    NASA Astrophysics Data System (ADS)

    Sun, Yang; Liao, Kuo-Chih; Sun, Yinghua; Park, Jesung; Marcu, Laura

    2008-02-01

    A unique tissue phantom is reported here that mimics the optical and acoustical properties of biological tissue and enables testing and validation of a dual-modality clinical diagnostic system combining time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasound backscatter microscopy (UBM). The phantom consisted of contrast agents including silicon dioxide particles with a range of diameters from 0.5 to 10 μm acting as optical and acoustical scatterers, and FITC-conjugated dextran mimicking the endogenous fluorophore in tissue. The agents were encapsulated in a polymer bead attached to the end of an optical fiber with a 200 μm diameter using a UV-induced polymerization technique. A set of beads with fibers were then implanted into a gel-based matrix with controlled patterns including a design with lateral distribution and a design with successively changing depth. The configuration presented here allowed the validation of the hybrid fluorescence spectroscopic and ultrasonic system by detecting the lateral and depth distribution of the contrast agents, as well as for coregistration of the ultrasonic image with spectroscopic data. In addition, the depth of the beads in the gel matrix was changed to explore the effect of different concentration ratio of the mixture on the fluorescence signal emitted.

  17. Optical diagnosis of testicular torsion: feasibility and methodology

    NASA Astrophysics Data System (ADS)

    Shadgan, Babak; Macnab, Andrew; Stothers, Lynn; Kajbafzadeh, A. M.

    2014-03-01

    Background: Torsion of the testis compromises blood flow through the spermatic cord; testicular ischemia results which if not diagnosed promptly and corrected surgically irrevocably damages the testis. Current diagnostic modalities aimed at rationalizing surgical exploration by demonstrating interruption of spermatic cord blood flow or testicular ischemia have limited applicability. Near infrared spectroscopy (NIRS) offers a non-invasive optical method for detection of ischemia; continuous wave and frequency domain devices have been used experimentally; no device customized for clinical use has been designed. Methods: A miniature spatially resolved NIRS device with light emitting diode light source was applied over the right and left spermatic cord and the difference in oxygen saturation between the two sides measured. Results: In a 14-month old boy with a history of unilateral testicular pain color Doppler ultrasonography was equivocal but the NIRS-derived tissue oxygen saturation index (TSI) was significantly reduced on the left side. Confirmation of torsion of the left testicle was made surgically. Conclusions: Spatially resolved NIRS monitoring of spermatic cord oxygen saturation is feasible in children, adding to prior studies of testicular oxygen saturation in adults. Customized device design and further clinical trials would enhance the applicability of NIRS as a diagnostic entity for torsion.

  18. In situ distributed diagnostics of flowable electrode systems: resolving spatial and temporal limitations.

    PubMed

    Dennison, C R; Gogotsi, Y; Kumbur, E C

    2014-09-14

    In this study, we have developed an in situ distributed diagnostics tool to investigate spatial and temporal effects in electrochemical systems based on flowable electrodes. Specifically, an experimental approach was developed that enables spatially-resolved voltage measurements to be obtained in situ, in real-time. To extract additional data from these distributed measurements, an experimentally-parameterized equivalent circuit model with a new 'flow capacitor' circuit element was developed to predict the distributions of various system parameters during operation. As a case study, this approach was applied to investigate the behavior of the suspension electrodes used in an electrochemical flow capacitor under flowing and static conditions. The volumetric capacitance is reduced from 15.6 F ml(-1) to 1.1 F ml(-1) under flowing conditions. Results indicate that the majority of the charging in suspension electrodes occurs within ∼750 μm of the current collectors during flow, which gives rise to significant state-of-charge gradients across the cell, as well as underutilization of the available active material. The underlying cause of this observation is attributed to the relatively high electrical resistance of the slurry coupled with a stratified charging regime and insufficient residence time. The observations highlight the need to develop more conductive slurries and to design cells with reduced charge transport lengths.

  19. Development of a Nomarski-type multi-frame interferometer as a time and space resolving diagnostics for the free electron density of laser-generated plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boerner, M.; Frank, A.; Pelka, A.

    2012-04-15

    This article reports on the development and set-up of a Nomarski-type multi-frame interferometer as a time and space resolving diagnostics of the free electron density in laser-generated plasma. The interferometer allows the recording of a series of 4 images within 6 ns of a single laser-plasma interaction. For the setup presented here, the minimal accessible free electron density is 5 x 10{sup 18} cm{sup -3}, the maximal one is 2 x 10{sup 20} cm{sup -3}. Furthermore, it provides a resolution of the electron density in space of 50 {mu}m and in time of 0.5 ns for one image with amore » customizable magnification in space for each of the 4 images. The electron density was evaluated from the interferograms using an Abel inversion algorithm. The functionality of the system was proven during first experiments and the experimental results are presented and discussed. A ray tracing procedure was realized to verify the interferometry pictures taken. In particular, the experimental results are compared to simulations and show excellent agreement, providing a conclusive picture of the evolution of the electron density distribution.« less

  20. Application of Immunosignatures for Diagnosis of Valley Fever

    PubMed Central

    Navalkar, Krupa Arun; Johnston, Stephen Albert; Woodbury, Neal; Galgiani, John N.; Magee, D. Mitchell; Chicacz, Zbigniew

    2014-01-01

    Valley fever (VF) is difficult to diagnose, partly because the symptoms of VF are confounded with those of other community-acquired pneumonias. Confirmatory diagnostics detect IgM and IgG antibodies against coccidioidal antigens via immunodiffusion (ID). The false-negative rate can be as high as 50% to 70%, with 5% of symptomatic patients never showing detectable antibody levels. In this study, we tested whether the immunosignature diagnostic can resolve VF false negatives. An immunosignature is the pattern of antibody binding to random-sequence peptides on a peptide microarray. A 10,000-peptide microarray was first used to determine whether valley fever patients can be distinguished from 3 other cohorts with similar infections. After determining the VF-specific peptides, a small 96-peptide diagnostic array was created and tested. The performances of the 10,000-peptide array and the 96-peptide diagnostic array were compared to that of the ID diagnostic standard. The 10,000-peptide microarray classified the VF samples from the other 3 infections with 98% accuracy. It also classified VF false-negative patients with 100% sensitivity in a blinded test set versus 28% sensitivity for ID. The immunosignature microarray has potential for simultaneously distinguishing valley fever patients from those with other fungal or bacterial infections. The same 10,000-peptide array can diagnose VF false-negative patients with 100% sensitivity. The smaller 96-peptide diagnostic array was less specific for diagnosing false negatives. We conclude that the performance of the immunosignature diagnostic exceeds that of the existing standard, and the immunosignature can distinguish related infections and might be used in lieu of existing diagnostics. PMID:24964807

  1. An investigative framework to facilitate epidemiological thinking during herd problem-solving.

    PubMed

    More, Simon J; Doherty, Michael L; O'Grady, Luke

    2017-01-01

    Veterinary clinicians and students commonly use diagnostic approaches appropriate for individual cases when conducting herd problem-solving. However, these approaches can be problematic, in part because they make limited use of epidemiological principles and methods, which has clear application during the investigation of herd problems. In this paper, we provide an overview of diagnostic approaches that are used when investigating individual animal cases, and the challenges faced when these approaches are directly translated from the individual to the herd. Further, we propose an investigative framework to facilitate epidemiological thinking during herd problem-solving. A number of different approaches are used when making a diagnosis on an individual animal, including pattern recognition, hypothetico-deductive reasoning, and the key abnormality method. Methods commonly applied to individuals are often adapted for herd problem-solving: 'comparison with best practice' being a herd-level adaptation of pattern recognition, and 'differential diagnoses' a herd-level adaptation of hypothetico-deductive reasoning. These approaches can be effective, however, challenges can arise. Herds are complex; a collection of individual cows, but also additional layers relating to environment, management, feeding etc. It is unrealistic to expect seamless translation of diagnostic approaches from the individual to the herd. Comparison with best practice is time-consuming and prioritisation of actions can be problematic, whereas differential diagnoses can lead to 'pathogen hunting', particularly in complex cases. Epidemiology is the science of understanding disease in populations. The focus is on the population, underpinned by principles and utilising methods that seek to allow us to generate solid conclusions from apparently uncontrolled situations. In this paper, we argue for the inclusion of epidemiological principles and methods as an additional tool for herd problem-solving, and outline an investigative framework, with examples, to effectively incorporate these principles and methods with other diagnostic approaches during herd problem-solving. Relevant measures of performance are identified, and measures of case frequencies are calculated and compared across time, in space and among animal groupings, to identify patterns, clues and plausible hypotheses, consistent with potential biological processes. With this knowledge, the subsequent investigation (relevant on-farm activities, diagnostic testing and other examinations) can be focused, and actions prioritised (specifically, those actions that are likely to make the greatest difference in addressing the problem if enacted). In our experience, this investigative framework is an effective teaching tool, facilitating epidemiological thinking among students during herd problem-solving. It is a generic and robust process, suited to many herd-based problems.

  2. Alcohol Use Disorders in Argentinian Girls and Women 12 Months Before Delivery: Comparison of DSM-IV, DSM-5, and ICD-10 Diagnostic Criteria.

    PubMed

    López, Mariana B; Conde, Karina; Cremonte, Mariana

    The evidence of important problems related to prenatal alcohol exposure has faced researchers with the problem of understanding and screening alcohol use in this population. Although any alcohol use should be considered risky during pregnancy, identifying alcohol-drinking problems (ADPs) could be especially important because women with ADPs could not benefit from a simple advice of abstinence and because their offsprings are subjected to a higher risk of problems related with prenatal alcohol exposure. In this context, we aim to study the prevalence and characteristics of ADPs in pregnant women, evaluating the performance of different diagnostic systems in this population. The aims of the study were to describe the prevalence of ADPs obtained with the criteria of the Diagnostic and Statistical Manual of Mental Disorders in its fourth (DSM-IV) and fifth edition (DSM-5), and the International Classification of Diseases (ICD)-10, in Argentinean females aged 13 to 44 years, 12 months before delivery; to evaluate the level of agreement between these classification systems; and to analyze the performance of each diagnosis criterion in this population. Data were collected through personal interviews of a probability sample of puerperal women (N = 641) in the city of Santa Fe (Argentina), between October 2010 and February 2011. Diagnoses compatible with DSM-IV, DSM-5, and ICD-10 were obtained through the Composite International Diagnostic Interview. Agreement among diagnostic systems was measured through Cohen kappa. Diagnosis criteria performance were analyzed considering their prevalence and discriminating ability (D value). Total ADP prevalence was 6.4% for DSM-IV (4.2% abuse and 2.2% dependence), 8.1% for DSM-5 (6.4% mild, 0.8% moderate, and 0.9% severe alcohol use disorder), and 14.1% for the ICD-10 (11.9% harmful use and 2.2% dependence). DSM-5 modifications improved agreement between DSM and ICD. The least prevalent and worst discriminating ability diagnostic criterion was "legal problems." The most prevalent and 1 of the best discriminating ability diagnostic criterion was '"health issues." DSM-IV and ICD-10 dependence prevalence was similar to that of previous studies in pregnant women, whereas abuse prevalence was surprisingly higher. Our results indicate a better performance of the DSM-5 alcohol use disorder category relative to the DSM-IV dual categorization. Nevertheless, the poor diagnostic performance of some DSM-5 criteria in this population could evidence their intercultural variability.

  3. Single molecule real-time (SMRT) sequencing comes of age: applications and utilities for medical diagnostics

    PubMed Central

    Ardui, Simon; Ameur, Adam; Vermeesch, Joris R; Hestand, Matthew S

    2018-01-01

    Abstract Short read massive parallel sequencing has emerged as a standard diagnostic tool in the medical setting. However, short read technologies have inherent limitations such as GC bias, difficulties mapping to repetitive elements, trouble discriminating paralogous sequences, and difficulties in phasing alleles. Long read single molecule sequencers resolve these obstacles. Moreover, they offer higher consensus accuracies and can detect epigenetic modifications from native DNA. The first commercially available long read single molecule platform was the RS system based on PacBio's single molecule real-time (SMRT) sequencing technology, which has since evolved into their RSII and Sequel systems. Here we capsulize how SMRT sequencing is revolutionizing constitutional, reproductive, cancer, microbial and viral genetic testing. PMID:29401301

  4. ECE-imaging of the H-mode pedestal (invited).

    PubMed

    Tobias, B J; Austin, M E; Boom, J E; Burrell, K H; Classen, I G J; Domier, C W; Luhmann, N C; Nazikian, R; Snyder, P B

    2012-10-01

    A synthetic diagnostic has been developed that reproduces the highly structured electron cyclotron emission (ECE) spectrum radiated from the edge region of H-mode discharges. The modeled dependence on local perturbations of the equilibrium plasma pressure allows for interpretation of ECE data for diagnosis of local quantities. Forward modeling of the diagnostic response in this region allows for improved mapping of the observed fluctuations to flux surfaces within the plasma, allowing for the poloidal mode number of coherent structures to be resolved. In addition, other spectral features that are dependent on both T(e) and n(e) contain information about pedestal structure and the electron energy distribution of localized phenomena, such as edge filaments arising during edge-localized mode (ELM) activity.

  5. Energy resolved actinometry for simultaneous measurement of atomic oxygen densities and local mean electron energies in radio-frequency driven plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greb, Arthur, E-mail: ag941@york.ac.uk; Niemi, Kari; O'Connell, Deborah

    2014-12-08

    A diagnostic method for the simultaneous determination of atomic oxygen densities and mean electron energies is demonstrated for an atmospheric pressure radio-frequency plasma jet. The proposed method is based on phase resolved optical emission measurements of the direct and dissociative electron-impact excitation dynamics of three distinct emission lines, namely, Ar 750.4 nm, O 777.4 nm, and O 844.6 nm. The energy dependence of these lines serves as basis for analysis by taking into account two line ratios. In this frame, the method is highly adaptable with regard to pressure and gas composition. Results are benchmarked against independent numerical simulations and two-photon absorption laser-inducedmore » fluorescence experiments.« less

  6. Irrational exuberance for resolved species trees.

    PubMed

    Hahn, Matthew W; Nakhleh, Luay

    2016-01-01

    Phylogenomics has largely succeeded in its aim of accurately inferring species trees, even when there are high levels of discordance among individual gene trees. These resolved species trees can be used to ask many questions about trait evolution, including the direction of change and number of times traits have evolved. However, the mapping of traits onto trees generally uses only a single representation of the species tree, ignoring variation in the gene trees used to construct it. Recognizing that genes underlie traits, these results imply that many traits follow topologies that are discordant with the species topology. As a consequence, standard methods for character mapping will incorrectly infer the number of times a trait has evolved. This phenomenon, dubbed "hemiplasy," poses many problems in analyses of character evolution. Here we outline these problems, explaining where and when they are likely to occur. We offer several ways in which the possible presence of hemiplasy can be diagnosed, and discuss multiple approaches to dealing with the problems presented by underlying gene tree discordance when carrying out character mapping. Finally, we discuss the implications of hemiplasy for general phylogenetic inference, including the possible drawbacks of the widespread push for "resolved" species trees. © 2015 The Author(s). Evolution © 2015 The Society for the Study of Evolution.

  7. Collis-Romberg Mathematical Problem Solving Profiles.

    ERIC Educational Resources Information Center

    Collis, K. F.; Romberg, T. A.

    Problem solving has become a focus of mathematics programs in Australia in recent years, necessitating the assessment of students' problem-solving abilities. This manual provides a problem-solving assessment and teaching resource package containing four elements: (1) profiles assessment items; (2) profiles diagnostic forms for recording individual…

  8. Drinking correlates of DSM-IV alcohol use disorder diagnostic orphans in college students.

    PubMed

    Hagman, Brett T; Cohn, Amy M

    2012-01-01

    One major limitation of the DSM-IV criteria for alcohol abuse and dependence is that a cluster of individuals who endorse a subthreshold number of dependence criteria and no abuse criteria do not receive a formal diagnosis; despite elevated risk for alcohol-related problems relative to those with an abuse diagnosis. These individuals have been referred to as diagnostic orphans. The primary aim of this study was to examine alcohol use correlates of a group of diagnostic orphans in a sample of 396 nontreatment seeking college students who reported drinking on at least one occasion in the last 90 days. DSM-IV criteria were assessed using a modified version of the Composite International Diagnostic Interview-Substance Abuse Module (CIDI-SAM). Diagnostic orphans represented 34.1% (n = 135) of the original sample who did not receive a formal diagnosis; with the most frequently endorsed dependence criteria being tolerance and drinking larger/longer amounts than intended. Diagnostic orphans reported a range of alcohol-related negative consequences and reported greater frequencies of social and enhancement drinking motives in comparison to coping motives. They were similar to alcohol abusers and dissimilar to those with dependence or those without a diagnosis on alcohol consumption, alcohol problem severity, drinking motives and restraint variables. The present findings indicate that diagnostic orphans in college students represent a distinct group of drinkers who may be at risk for the development of alcohol use disorders and may be in need of intervention, given their similarity to those with an abuse diagnosis. Prevention and intervention efforts across college campuses should target this group to prevent escalation of alcohol problem severity. Copyright © American Academy of Addiction Psychiatry.

  9. Repair Negotiation by English L2 Learners

    ERIC Educational Resources Information Center

    Choi, Yujeong

    2012-01-01

    It is widely accepted that L2 learners often face communication problems due to lack of competency in the target language and familiarity with its culture of origin. One way to resolve miscommunication problems is to seek clarification of the utterance; this process is called "repair negotiation" (Nakahama et al. 2001). Repair…

  10. Mediation Plus Options To Resolve the "Real" Problems Underlying Disputes.

    ERIC Educational Resources Information Center

    Beekman, Lyn

    This paper discusses alternatives to court litigation in special education disputes between schools and parents of students with disabilities. It begins by describing problems with the current hearing process and dispelling myths about alternative dispute resolutions (ADR). The advantages and disadvantages of mediation are then outlined, along…

  11. Reconciling Representations

    ERIC Educational Resources Information Center

    Zahner, William; Dent, Nick

    2014-01-01

    Sometimes a student's unexpected solution turns a routine classroom task into a real problem, one that the teacher cannot resolve right away. Although not knowing the answer can be uncomfortable for a teacher, these moments of uncertainty are also an opportunity to model authentic problem solving. This article describes such a moment in Zahner's…

  12. DEMONSTRATION OF A MULTI-SCALE INTEGRATED MONITORING AND ASSESSMENT IN NY/NJ HARBOR

    EPA Science Inventory

    The Clean Water Act (CWA) requires states and tribes to assess the overall quality of their waters (Sec 305(b)), determine whether that quality is changing over time, identify problem areas and management actions necessary to resolve those problems, and evaluate the effectiveness...

  13. Replication of Psycholinguistic Experiments and the Resolution of Inconsistencies

    ERIC Educational Resources Information Center

    Rákosi, Csilla

    2017-01-01

    Non-exact replications are regarded as effective tools of problem solving in psycholinguistic research because they lead to more plausible experimental results; however, they are also ineffective tools of problem solving because they trigger cumulative contradictions among different replications of an experiment. This paper intends to resolve this…

  14. Indoor Air Quality Guidelines for Pennsylvania Schools.

    ERIC Educational Resources Information Center

    Zimmerman, Robert S., Jr.

    This report provides information and practical guidance on how to prevent indoor air quality (IAQ) problems in schools, and it describes how to implement a practical plan of action using a minimal amount of resources. It includes general guidelines to prevent or help resolve IAQ problems, guidelines on specific indoor contaminants, recommendations…

  15. Assessment in Multisite Randomized Clinical Trials of Patients with Autistic Disorder: The Autism RUPP Network.

    ERIC Educational Resources Information Center

    Arnold, L. Eugene; Aman, Michael G.; Martin, Andres; Collier-Crespin, Angie; Vitiello, Benedetto; Tierney, Elaine; Asarnow, Robert; Bell-Bradshaw, Felicia; Freeman, Betty Jo; Gates-Ulanet, Patricia; Klin, Ami; McCracken, James T.; McDougle, Christopher J.; McGough, James J.; Posey, David J.; Scahill, Lawrence; Swiezy, Naomi B.; Ritz, Louise; Volkmar, Fred

    2000-01-01

    This paper explains how the Autism Research Units on Pediatric Psychopharmacology (RUPP Autism Network) resolved common assessment problems including communication problems compromising use of the patient as informant, broad subject heterogeneity, difficulties in assessing low-end IQs, scarcity of autism-adapted cognitive and neuropsychological…

  16. 76 FR 41448 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-14

    ... notification. Copies of the submission(s) may be obtained by calling (202) 720-8681. An agency may not conduct... servicing policies for the loans and grants in questions. If there is a problem which exists, a recipient of... resolving the problem through reamortization, sale, transfer, debt restructuring, liquidation, or other...

  17. Positive Strategies for Students with Behavior Problems

    ERIC Educational Resources Information Center

    Crimmins, Daniel; Farrell, Anne F.; Smith, Philip W.; Bailey, Alison

    2007-01-01

    When a student's challenging behavior can not be resolved through either traditional disciplinary approaches or schoolwide positive behavior support (PBS), what can a teacher do next? This manual has effective solutions for educators from grades K-12. Developed specifically for use with children with persistent or severe behavior problems, this…

  18. Why Reading Fluency Should Be Hot

    ERIC Educational Resources Information Center

    Rasinski, Timothy V.

    2012-01-01

    This article explores problems that have surfaced in the teaching of reading fluency and how teachers and reading coaches can resolve those problems. Specific issues addressed include reading fluency being defined as reading fast and instruction that is focused on having students read fast, reading fluency viewed as solely and oral reading…

  19. Rooting of conifer propagules

    Treesearch

    R.L. Mott

    1977-01-01

    An outline of the general problems involved with the propagation of elite conifer clones by rooted cuttings is drawn from published reports. New approaches for resolving these problems can come from studies of clone production through tissue culture methods. Probable extension of tissue culture techniques will permit the establishment of clones from adult, proven trees...

  20. Rescuing Computerized Testing by Breaking Zipf's Law.

    ERIC Educational Resources Information Center

    Wainer, Howard

    2000-01-01

    Suggests that because of the nonlinear relationship between item usage and item security, the problems of test security posed by continuous administration of standardized tests cannot be resolved merely by increasing the size of the item pool. Offers alternative strategies to overcome these problems, distributing test items so as to avoid the…

  1. Population Growth and Global Security: Toward an American Strategic Commitment.

    ERIC Educational Resources Information Center

    Mumford, Steven

    1981-01-01

    Addresses the world population problem by highlighting three crucial areas: the relationship between population growth control and national security issues, the role of American leadership in resolving the problem, and the barriers to effective action. One barrier discussed in detail is the Roman Catholic Church's stand on abortion and…

  2. Resolving Relationship Problems in Communication Disorders Treatment: A Systems Approach.

    ERIC Educational Resources Information Center

    Stone, Judith R.

    1992-01-01

    Systems concepts from general systems theory and family therapy literature are presented as analytical tools to help professionals understand and change interactions with their clients having communication disorders. Two case examples that illustrate relationship problems are presented, and approaches taken to their resolution are described.…

  3. A Passage in Time

    ERIC Educational Resources Information Center

    Language Teaching, 2014

    2014-01-01

    The translator's craft lies first in his command of an exceptionally large vocabulary as well as all syntactic resources--his ability to use them elegantly, flexibly, succinctly. All translation problems finally resolve themselves into problems of how to write well in the target language. Benjamin (1923) stated that in a good work, language…

  4. Study of Varying Boundary Layer Height on Turret Flow Structures

    DTIC Science & Technology

    2011-06-01

    fluid dynamics. The difficulties of the problem arise in modeling several complex flow features including separation, reattachment, three-dimensional...impossible. In this case, the approach is to create a model to calculate the properties of interest. The main issue with resolving turbulent flows...operation and their effect is modeled through subgrid scale models . As a result, the the most important turbulent scales are resolved and the

  5. A General Architecture for Intelligent Tutoring of Diagnostic Classification Problem Solving

    PubMed Central

    Crowley, Rebecca S.; Medvedeva, Olga

    2003-01-01

    We report on a general architecture for creating knowledge-based medical training systems to teach diagnostic classification problem solving. The approach is informed by our previous work describing the development of expertise in classification problem solving in Pathology. The architecture envelops the traditional Intelligent Tutoring System design within the Unified Problem-solving Method description Language (UPML) architecture, supporting component modularity and reuse. Based on the domain ontology, domain task ontology and case data, the abstract problem-solving methods of the expert model create a dynamic solution graph. Student interaction with the solution graph is filtered through an instructional layer, which is created by a second set of abstract problem-solving methods and pedagogic ontologies, in response to the current state of the student model. We outline the advantages and limitations of this general approach, and describe it’s implementation in SlideTutor–a developing Intelligent Tutoring System in Dermatopathology. PMID:14728159

  6. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    PubMed

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  7. An Experimental Copyright Moratorium: Study of a Proposed Solution to the Copyright Photocopying Problem. Final Report to the American Society for Testing and Materials (ASTM).

    ERIC Educational Resources Information Center

    Heilprin, Laurence B.

    The Committee to Investigate Copyright Problems (CICP), a non-profit organization dedicated to resolving the conflict known as the "copyright photocopying problem" was joined by the American Society for Testing and Materials (ASTM), a large national publisher of technical and scientific standards, in a plan to simulate a long-proposed…

  8. Year 2000 Readiness Kit: A Compilation of Y2K Resources for Schools, Colleges and Universities.

    ERIC Educational Resources Information Center

    Department of Education, Washington, DC.

    This kit was developed to assist the postsecondary education community's efforts to resolve the Year 2000 (Y2K) computer problem. The kit includes a description of the Y2K problem, an assessment of the readiness of colleges and universities, a checklist for institutions, a Y2K communications strategy, articles on addressing the problem in academic…

  9. Time-resolved optical spectroscopic quantification of red blood cell damage caused by cardiovascular devices

    NASA Astrophysics Data System (ADS)

    Sakota, D.; Sakamoto, R.; Sobajima, H.; Yokoyama, N.; Yokoyama, Y.; Waguri, S.; Ohuchi, K.; Takatani, S.

    2008-02-01

    Cardiovascular devices such as heart-lung machine generate un-physiological level of shear stress to damage red blood cells, leading to hemolysis. The diagnostic techniques of cell damages, however, have not yet been established. In this study, the time-resolved optical spectroscopy was applied to quantify red blood cell (RBC) damages caused by the extracorporeal circulation system. Experimentally, the fresh porcine blood was subjected to varying degrees of shear stress in the rotary blood pump, followed with measurement of the time-resolved transmission characteristics using the pico-second pulses at 651 nm. The propagated optical energy through the blood specimen was detected using a streak camera. The data were analyzed in terms of the mean cell volume (MCV) and mean cell hemoglobin concentration (MCHC) measured separately versus the energy and propagation time of the light pulses. The results showed that as the circulation time increased, the MCV increased with decrease in MCHC. It was speculated that the older RBCs with smaller size and fragile membrane properties had been selectively destroyed by the shear stress. The time-resolved optical spectroscopy is a useful technique in quantifying the RBCs' damages by measuring the energy and propagation time of the ultra-short light pulses through the blood.

  10. Time-Resolved Optical Measurements of Fuel-Air Mixedness in Windowless High Speed Research Combustors

    NASA Technical Reports Server (NTRS)

    Nguyen, Quang-Viet

    1998-01-01

    Fuel distribution measurements in gas turbine combustors are needed from both pollution and fuel-efficiency standpoints. In addition to providing valuable data for performance testing and engine development, measurements of fuel distributions uniquely complement predictive numerical simulations. Although equally important as spatial distribution, the temporal distribution of the fuel is an often overlooked aspect of combustor design and development. This is due partly to the difficulties in applying time-resolved diagnostic techniques to the high-pressure, high-temperature environments inside gas turbine engines. Time-resolved measurements of the fuel-to-air ratio (F/A) can give researchers critical insights into combustor dynamics and acoustics. Beginning in early 1998, a windowless technique that uses fiber-optic, line-of-sight, infrared laser light absorption to measure the time-resolved fluctuations of the F/A (refs. 1 and 2) will be used within the premixer section of a lean-premixed, prevaporized (LPP) combustor in NASA Lewis Research Center's CE-5 facility. The fiber-optic F/A sensor will permit optical access while eliminating the need for film-cooled windows, which perturb the flow. More importantly, the real-time data from the fiber-optic F/A sensor will provide unique information for the active feedback control of combustor dynamics. This will be a prototype for an airborne sensor control system.

  11. Time-resolved High Spectral Resolution Observation of 2MASSW J0746425+200032AB

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Ji; Mawet, Dimitri; Prato, Lisa, E-mail: ji.wang@caltech.edu

    Many brown dwarfs (BDs) exhibit photometric variability at levels from tenths to tens of percents. The photometric variability is related to magnetic activity or patchy cloud coverage, characteristic of BDs near the L–T transition. Time-resolved spectral monitoring of BDs provides diagnostics of cloud distribution and condensate properties. However, current time-resolved spectral studies of BDs are limited to low spectral resolution ( R ∼ 100) with the exception of the study of Luhman 16 AB at a resolution of 100,000 using the VLT+CRIRES. This work yielded the first map of BD surface inhomogeneity, highlighting the importance and unique contribution of highmore » spectral resolution observations. Here, we report on the time-resolved high spectral resolution observations of a nearby BD binary, 2MASSW J0746425+200032AB. We find no coherent spectral variability that is modulated with rotation. Based on simulations, we conclude that the coverage of a single spot on 2MASSW J0746425+200032AB is smaller than 1% or 6.25% if spot contrast is 50% or 80% of its surrounding flux, respectively. Future high spectral resolution observations aided by adaptive optics systems can put tighter constraints on the spectral variability of 2MASSW J0746425+200032AB and other nearby BDs.« less

  12. Layout and results from the initial operation of the high-resolution x-ray imaging crystal spectrometer on the Large Helical Device.

    PubMed

    Pablant, N A; Bitter, M; Delgado-Aparicio, L; Goto, M; Hill, K W; Lazerson, S; Morita, S; Roquemore, A L; Gates, D; Monticello, D; Nielson, H; Reiman, A; Reinke, M; Rice, J E; Yamada, H

    2012-08-01

    First results of ion and electron temperature profile measurements from the x-ray imaging crystal spectrometer (XICS) diagnostic on the Large Helical Device (LHD) are presented. This diagnostic system has been operational since the beginning of the 2011 LHD experimental campaign and is the first application of the XICS diagnostic technique to helical plasma geometry. The XICS diagnostic provides measurements of ion and electron temperature profiles in LHD with a spatial resolution of 2 cm and a maximum time resolution of 5 ms (typically 20 ms). Ion temperature profiles from the XICS diagnostic are possible under conditions where charge exchange recombination spectroscopy (CXRS) is not possible (high density) or is perturbative to the plasma (low density or radio frequency heated plasmas). Measurements are made by using a spherically bent crystal to provide a spectrally resolved 1D image of the plasma from line integrated emission of helium-like Ar(16 +). The final hardware design and configuration are detailed along with the calibration procedures. Line-integrated ion and electron temperature measurements are presented, and the measurement accuracy is discussed. Finally central temperature measurements from the XICS system are compared to measurements from the Thomson scattering and CXRS systems, showing excellent agreement.

  13. Design of a beam emission spectroscopy diagnostic for negative ions radio frequency source SPIDER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaniol, B.; Pasqualotto, R.; Barbisan, M.

    2012-04-15

    A facility will be built in Padova (Italy) to develop, commission, and optimize the neutral beam injection system for ITER. The full scale prototype negative ion radio frequency source SPIDER, featuring up to 100 kV acceleration voltage, includes a full set of diagnostics, required for safe operation and to measure and optimize the beam performance. Among them, beam emission spectroscopy (BES) will be used to measure the line integrated beam uniformity, divergence, and neutralization losses inside the accelerator (stripping losses). In the absence of the neutralization stage, SPIDER beam is mainly composed by H{sup -} or D{sup -} particles, accordingmore » to the source filling gas. The capability of a spectroscopic diagnostic of an H{sup -} (D{sup -}) beam relies on the interaction of the beam particles with the background gas particles. The BES diagnostic will be able to acquire the H{sub {alpha}} (D{sub {alpha}}) spectrum from up to 40 lines of sight. The system is capable to resolve stripping losses down to 2 keV and to measure beam divergence with an accuracy of about 10%. The design of this diagnostic is reported, with discussion of the layout and its components, together with simulations of the expected performance.« less

  14. Use of PCR in resolving diagnostic difficulties potentially caused by genetic variation of hepatitis B virus.

    PubMed Central

    van Deursen, F J; Hino, K; Wyatt, D; Molyneaux, P; Yates, P; Wallace, L A; Dow, B C; Carman, W F

    1998-01-01

    AIMS: To assess the relevance of genetic variants of hepatitis B virus (HBV) and to demonstrate the usefulness of the polymerase chain reaction (PCR) in cases of HBV diagnostic difficulty. METHODS: Five serum samples from patients that presented diagnostic difficulty in routine laboratories were sent to a research laboratory for PCR, and if appropriate, S gene sequencing, in vitro expression, and antigenic analysis. RESULTS: The demonstration of HBV in serum by PCR allowed a definitive diagnosis of current infection. One serum sample with poor reactivity in a diagnostic assay had a minor hepatitis B surface antigen (HBsAg) variant and another with very poor reactivity had multiple variants of HBsAg. Transient HBsAg reactivity was observed in a recently vaccinated patient. A hepatitis Be antigen (HBeAg) false positive reaction was noted in a patient from a well defined risk group for HBV. One patient who was strongly HBsAg/HBeAg positive, but anti-hepatitis B core antibody negative, was viraemic. CONCLUSIONS: PCR may become the gold standard for the diagnosis of current HBV infection. HBV variants are responsible for a proportion of diagnostically difficult cases. Modification of commercial assays is necessary to increase the sensitivity of detection of such variants. PMID:9602690

  15. Self-assembly of virus-like particles of canine parvovirus capsid protein expressed from Escherichia coli and application as virus-like particle vaccine.

    PubMed

    Xu, Jin; Guo, Hui-Chen; Wei, Yan-Quan; Dong, Hu; Han, Shi-Chong; Ao, Da; Sun, De-Hui; Wang, Hai-Ming; Cao, Sui-Zhong; Sun, Shi-Qi

    2014-04-01

    Canine parvovirus disease is an acute infectious disease caused by canine parvovirus (CPV). Current commercial vaccines are mainly attenuated and inactivated; as such, problems concerning safety may occur. To resolve this problem, researchers developed virus-like particles (VLPs) as biological nanoparticles resembling natural virions and showing high bio-safety. This property allows the use of VLPs for vaccine development and mechanism studies of viral infections. Tissue-specific drug delivery also employs VLPs as biological nanomaterials. Therefore, VLPs derived from CPV have a great potential in medicine and diagnostics. In this study, small ubiquitin-like modifier (SUMO) fusion motif was utilized to express a whole, naturalVP2 protein of CPV in Escherichia coli. After the cleavage of the fusion motif, the CPV VP2 protein has self-assembled into VLPs. The VLPs had a size and shape that resembled the authentic virus capsid. However, the self-assembly efficiency of VLPs can be affected by different pH levels and ionic strengths. The mice vaccinated subcutaneously with CPV VLPs and CPV-specific immune responses were compared with those immunized with the natural virus. This result showed that VLPs can effectively induce anti-CPV specific antibody and lymphocyte proliferation as a whole virus. This result further suggested that the antigen epitope of CPV was correctly present on VLPs, thereby showing the potential application of a VLP-based CPV vaccine.

  16. Eating disorders: progress and challenges.

    PubMed

    Dalle Grave, Riccardo

    2011-04-01

    Eating disorders are common health problems afflicting mainly female adolescents and young women. They are associated with important physical health and psychosocial morbidity, and carry increased risk of death. Their cause is not yet completely understood and their management is complex, with some patients resisting all available treatments. AIMS OF THIS REVIEW: To provide the readers with an update regarding our knowledge and understanding of eating disorders. Medline database has been used for searching articles on eating disorders published since 1980. The key words used were eating disorders, anorexia nervosa, bulimia nervosa, bulimia, and binge eating. Professional books published during this period has been also reviewed. In the last 30 years a substantial improvement has been achieved both in the understanding and management of eating disorders, but many problems still need to be resolved. Three principal priorities should be addressed. First, the actual classification of eating disorders should be revised, since about half the cases seen in clinical practice receive a diagnosis of eating disorder not otherwise specified, and it is common to observe a migration between eating disorder diagnoses. Second, the research on pathogenesis should better clarify the exact role of genetic and environmental risk factors, and how they interact and vary across the development and maintenance of eating disorders. Third, there is an urgent need both to disseminate the few evidence-based treatments available, and to develop more potent treatments for all the eating disorder diagnostic categories. Copyright © 2010 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  17. The Portable Patient Problem Pack: A Problem-Based Learning Unit

    ERIC Educational Resources Information Center

    Barrows, Howard S.; Tamblyn, Robyn M.

    1977-01-01

    The Portable Patient Problem Pack (P4), a method of simulating a patient's problem in a card deck format, is designed to develop the student's problem-solving or diagnostic skills in a manner consistent with the skills of the practicing clinician. Its effectiveness at McMaster University is reported. (LBH)

  18. Intellectual, behavioral, and emotional functioning in children with syndromic craniosynostosis.

    PubMed

    Maliepaard, Marianne; Mathijssen, Irene M J; Oosterlaan, Jaap; Okkerse, Jolanda M E

    2014-06-01

    To examine intellectual, behavioral, and emotional functioning of children who have syndromic craniosynostosis and to explore differences between diagnostic subgroups. A national sample of children who have syndromic craniosynostosis participated in this study. Intellectual, behavioral, and emotional outcomes were assessed by using standardized measures: Wechsler Intelligence Scale for Children, Third Edition, Child Behavior Checklist (CBCL)/6-18, Disruptive Behavior Disorder rating scale (DBD), and the National Institute of Mental Health Diagnostic Interview Schedule for Children. We included 82 children (39 boys) aged 6 to 13 years who have syndromic craniosynostosis. Mean Full-Scale IQ (FSIQ) was in the normal range (M = 96.6; SD = 21.6). However, children who have syndromic craniosynostosis had a 1.9 times higher risk for developing intellectual disability (FSIQ < 85) compared with the normative population (P < .001) and had more behavioral and emotional problems compared with the normative population, including higher scores on the CBCL/6-18, DBD Total Problems (P < .001), Internalizing (P < .01), social problems (P < .001), attention problems (P < .001), and the DBD Inattention (P < .001). Children who have Apert syndrome had lower FSIQs (M = 76.7; SD = 13.3) and children who have Muenke syndrome had more social problems (P < .01), attention problems (P < .05), and inattention problems (P < .01) than normative population and with other diagnostic subgroups. Although children who have syndromic craniosynostosis have FSIQs similar to the normative population, they are at increased risk for developing intellectual disability, internalizing, social, and attention problems. Higher levels of behavioral and emotional problems were related to lower levels of intellectual functioning.

  19. DNA-Based Methods in the Immunohematology Reference Laboratory

    PubMed Central

    Denomme, Gregory A

    2010-01-01

    Although hemagglutination serves the immunohematology reference laboratory well, when used alone, it has limited capability to resolve complex problems. This overview discusses how molecular approaches can be used in the immunohematology reference laboratory. In order to apply molecular approaches to immunohematology, knowledge of genes, DNA-based methods, and the molecular bases of blood groups are required. When applied correctly, DNA-based methods can predict blood groups to resolve ABO/Rh discrepancies, identify variant alleles, and screen donors for antigen-negative units. DNA-based testing in immunohematology is a valuable tool used to resolve blood group incompatibilities and to support patients in their transfusion needs. PMID:21257350

  20. Natural course of behavioral addictions: a 5-year longitudinal study.

    PubMed

    Konkolÿ Thege, Barna; Woodin, Erica M; Hodgins, David C; Williams, Robert J

    2015-01-22

    Resolving the theoretical controversy on the labeling of an increasing number of excessive behaviors as behavioral addictions may also be facilitated by more empirical data on these behavioral problems. For instance, an essential issue to the classification of psychiatric disorders is information on their natural course. However, longitudinal research on the chronic vs. episodic nature of behavioral addictions is scarce. The aim of the present study, therefore, was to provide data on prevalence, substance use comorbidity, and five-year trajectories of six excessive behaviors-namely exercising, sexual behavior, shopping, online chatting, video gaming, and eating. Analyses were based on the data of the Quinte Longitudinal Study, where a cohort of 4,121 adults from Ontario, Canada was followed for 5 years (2006 to 2011). The response rate was 21.3%, while retention rate was 93.9%. To assess the occurrence of each problem behavior, a single self-diagnostic question asked people whether their over-involvement in the behavior had caused significant problems for them in the past 12 months. To assess the severity of each problem behavior reported, the Behavioral Addiction Measure was administered. A mixed design ANOVA was used to investigate symptom trajectories over time for each problem behavior and whether these symptom trajectories varied as a function of sex. The large majority of people reported having problematic over-involvement for just one of these behaviors and just in a single time period. A main effect of time was found for each problem behavior, indicating a moderately strong decrease in symptom severity across time. The time x sex interaction was insignificant in each model indicating that the decreasing trend is similar for males and females. The data also showed that help seeking was very low in the case of excessive sexual behavior, shopping, online chatting, and video gaming but substantially more prevalent in the case of excessive eating and exercising. The present results indicate that self-identified excessive exercising, sexual behavior, shopping, online chatting, video gaming, and/or eating tend to be fairly transient for most people. This aspect of the results is inconsistent with conceptualizations of addictions as progressive in nature, unless treated.

  1. A Diagnostic Assessment of Evolutionary Multiobjective Optimization for Water Resources Systems

    NASA Astrophysics Data System (ADS)

    Reed, P.; Hadka, D.; Herman, J.; Kasprzyk, J.; Kollat, J.

    2012-04-01

    This study contributes a rigorous diagnostic assessment of state-of-the-art multiobjective evolutionary algorithms (MOEAs) and highlights key advances that the water resources field can exploit to better discover the critical tradeoffs constraining our systems. This study provides the most comprehensive diagnostic assessment of MOEAs for water resources to date, exploiting more than 100,000 MOEA runs and trillions of design evaluations. The diagnostic assessment measures the effectiveness, efficiency, reliability, and controllability of ten benchmark MOEAs for a representative suite of water resources applications addressing rainfall-runoff calibration, long-term groundwater monitoring (LTM), and risk-based water supply portfolio planning. The suite of problems encompasses a range of challenging problem properties including (1) many-objective formulations with 4 or more objectives, (2) multi-modality (or false optima), (3) nonlinearity, (4) discreteness, (5) severe constraints, (6) stochastic objectives, and (7) non-separability (also called epistasis). The applications are representative of the dominant problem classes that have shaped the history of MOEAs in water resources and that will be dominant foci in the future. Recommendations are provided for which modern MOEAs should serve as tools and benchmarks in the future water resources literature.

  2. Diagnostics and characterization of nanodust and nanodusty plasmas★

    NASA Astrophysics Data System (ADS)

    Greiner, Franko; Melzer, Andrè; Tadsen, Benjamin; Groth, Sebastian; Killer, Carsten; Kirchschlager, Florian; Wieben, Frank; Pilch, Iris; Krüger, Harald; Block, Dietmar; Piel, Alexander; Wolf, Sebastian

    2018-05-01

    Plasmas growing or containing nanometric dust particles are widely used and proposed in plasma technological applications for production of nano-crystals and surface deposition. Here, we give a compact review of in situ methods for the diagnostics of nanodust and nanodusty plasmas, which have been developed in the framework of the SFB-TR24 to fully characterize these systems. The methods include kinetic Mie ellipsometry, angular-resolved Mie scattering, and 2D imaging Mie ellipsometry to get information about particle growth processes, particle sizes and particle size distributions. There, also the role of multiple scattering events is analyzed using radiative transfer simulations. Computed tomography and Abel inversion techniques to get the 3D dust density profiles of the particle cloud will be presented. Diagnostics of the dust dynamics yields fundamental dust and plasma properties like particle charges and electron and ion densities. Since nanodusty plasmas usually form dense dust clouds electron depletion (Havnes effect) is found to be significant.

  3. The motional stark effect with laser-induced fluorescence diagnostic

    NASA Astrophysics Data System (ADS)

    Foley, E. L.; Levinton, F. M.

    2010-05-01

    The motional Stark effect (MSE) diagnostic is the worldwide standard technique for internal magnetic field pitch angle measurements in magnetized plasmas. Traditionally, it is based on using polarimetry to measure the polarization direction of light emitted from a hydrogenic species in a neutral beam. As the beam passes through the magnetized plasma at a high velocity, in its rest frame it perceives a Lorentz electric field. This field causes the H-alpha emission to be split and polarized. A new technique under development adds laser-induced fluorescence (LIF) to a diagnostic neutral beam (DNB) for an MSE measurement that will enable radially resolved magnetic field magnitude as well as pitch angle measurements in even low-field (<1 T) experiments. An MSE-LIF system will be installed on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. It will enable reconstructions of the plasma pressure, q-profile and current as well as, in conjunction with the existing MSE system, measurements of radial electric fields.

  4. Obsessive-compulsive personality disorder: a current review.

    PubMed

    Diedrich, Alice; Voderholzer, Ulrich

    2015-02-01

    This review provides a current overview on the diagnostics, epidemiology, co-occurrences, aetiology and treatment of obsessive-compulsive personality disorder (OCPD). The diagnostic criteria for OCPD according to the recently published Fifth Edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) include an official set of criteria for clinical practice and a new, alternative set of criteria for research purposes. OCPD is a personality disorder prevalent in the general population (3-8 %) that is more common in older and less educated individuals. Findings on sex distribution and course of OCPD are inconsistent. OCPD is comorbid with several other medical and psychological conditions. As for causes of OCPD, most empirical evidence provides support for disturbed attachment as well as the heritability of OCPD. So far, cognitive (behavioural) therapy is the best validated treatment of OCPD. Self-esteem variability, stronger early alliances as well as the distress level seem to predict cognitive (behavioural) therapy outcome. Future research is needed to further advance knowledge in OCPD and to resolve inconsistencies.

  5. Optical diagnostics on the Magnetized Shock Experiment (MSX)

    NASA Astrophysics Data System (ADS)

    Boguski, J. C.; Weber, T. E.; Intrator, T. P.; Smith, R. J.; Dunn, J. P.; Hutchinson, T. M.; Gao, K. W.

    2013-10-01

    The Magnetized Shock Experiment (MSX) at Los Alamos National Laboratory was built to investigate the physics of high Alfvén Mach number, supercritical, magnetized shocks through the acceleration and subsequent stagnation of a Field Reversed Configuration (FRC) plasmoid against a magnetic mirror and/or plasma target. A suite of optical diagnostics has recently been fielded on MSX to characterize plasma conditions during the formation, acceleration, and stagnation phases of the experiment. CCD-backed streak and framing cameras, and a fiber-based visible light array, provide information regarding FRC shape, velocity, and instability growth. Time-resolved narrow and broadband spectroscopy provides information on pre-shock plasma temperature, impurity levels, shock location, and non-thermal ion distributions within the shock region. Details of the diagnostic design, configuration, and characterization will be presented along with initial results. This work is supported by the Center for Magnetic Self Organization, DoE OFES and NNSA under LANS contract DE-AC52-06NA25369. Approved for public release: LA-UR- 13-25190.

  6. Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic

    NASA Astrophysics Data System (ADS)

    Kubala, S. Z.; Borchardt, M. T.; Den Hartog, D. J.; Holly, D. J.; Jacobson, C. M.; Morton, L. A.; Young, W. C.

    2016-11-01

    The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.

  7. Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic.

    PubMed

    Kubala, S Z; Borchardt, M T; Den Hartog, D J; Holly, D J; Jacobson, C M; Morton, L A; Young, W C

    2016-11-01

    The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV-5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz-25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.

  8. Recent advances in photodynamic diagnosis of gastric cancer using 5-aminolevulinic acid.

    PubMed

    Koizumi, Noriaki; Harada, Yoshinori; Minamikawa, Takeo; Tanaka, Hideo; Otsuji, Eigo; Takamatsu, Tetsuro

    2016-01-21

    Photodynamic diagnosis based on 5-aminolevulinic acid-induced protoporphyrin IX has been clinically applied in many fields based upon its evidenced efficacy and adequate safety. In order to establish a personalized medicine approach for treating gastric cancer patients, rapid intraoperative detection of malignant lesions has become important. Feasibility of photodynamic diagnosis using 5-aminolevulinic acid for gastric cancer patients has been investigated, especially for the detection of peritoneal dissemination and lymph node metastasis. This method enables intraoperative real-time fluorescence detection of peritoneal dissemination, exhibiting higher sensitivity than white light observation without histopathological examination. The method also enables detection of metastatic foci within excised lymph nodes, exhibiting a diagnostic accuracy comparable to that of a current molecular diagnostics technique. Although several complicating issues still need to be resolved, such as the effect of tissue autofluorescence and the insufficient depth penetration of excitation light, this simple and rapid method has the potential to become a useful diagnostic tool for gastric cancer, as well as urinary bladder cancer and glioma.

  9. Mid-infrared laser-absorption diagnostic for vapor-phase fuel mole fraction and liquid fuel film thickness

    NASA Astrophysics Data System (ADS)

    Porter, J. M.; Jeffries, J. B.; Hanson, R. K.

    2011-02-01

    A novel two-wavelength mid-infrared laser-absorption diagnostic has been developed for simultaneous measurements of vapor-phase fuel mole fraction and liquid fuel film thickness. The diagnostic was demonstrated for time-resolved measurements of n-dodecane liquid films in the absence and presence of n-decane vapor at 25°C and 1 atm. Laser wavelengths were selected from FTIR measurements of the C-H stretching band of vapor n-decane and liquid n-dodecane near 3.4 μm (3000 cm-1). n-Dodecane film thicknesses <20 μm were accurately measured in the absence of vapor, and simultaneous measurements of n-dodecane liquid film thickness and n-decane vapor mole fraction (300 ppm) were measured with <10% uncertainty for film thicknesses <10 μm. A potential application of the measurement technique is to provide accurate values of vapor mole fraction in combustion environments where strong absorption by liquid fuel or oil films on windows make conventional direct absorption measurements of the gas problematic.

  10. An overview of optical diagnostics developed for the Lockheed Martin compact fusion reactor

    NASA Astrophysics Data System (ADS)

    Sommers, Bradley; Raymond, Anthony; Gucker, Sarah; Lockheed Martin Compact Fusion Reactor Team

    2017-10-01

    The T4B experiment is a linear, encapsulated ring cusp confinement device, designed to develop a physics and technology basis for a follow-on high beta machine as part of the compact fusion reactor program. Toward this end, a collection of non-invasive optical diagnostics have been developed to investigate confinement, neutral beam heating, and source behavior on the T4B device. These diagnostics include: (1) a multipoint Thomson scattering system employing a 532 nm Nd:YAG laser and high throughput spectrometer to measure 1D profiles of electron density and temperature, (2) a dispersion interferometer utilizing a continuous-wave CO2 laser (10.6 μm) to measure time resolved, line-integrated electron density, and (3) a bolometer suite utilizing four AXUV photodiodes with 64 lines of sight to generate 2D reconstructions of total radiative power and soft x-ray emission (via beryllium filters). An overview of design methods, including laser systems, detection schemes, and data analysis techniques is presented as well as results to date.

  11. Strategy for the elucidation of elemental compositions of trace analytes based on a mass resolution of 100,000 full width at half maximum.

    PubMed

    Kaufmann, Anton

    2010-07-30

    Elemental compositions (ECs) can be elucidated by evaluating the high-resolution mass spectra of unknown or suspected unfragmented analyte ions. Classical approaches utilize the exact mass of the monoisotopic peak (M + 0) and the relative abundance of isotope peaks (M + 1 and M + 2). The availability of high-resolution instruments like the Orbitrap currently permits mass resolutions up to 100,000 full width at half maximum. This not only allows the determination of relative isotopic abundances (RIAs), but also the extraction of other diagnostic information from the spectra, such as fully resolved signals originating from (34)S isotopes and fully or partially resolved signals related to (15)N isotopes (isotopic fine structure). Fully and partially resolved peaks can be evaluated by visual inspection of the measured peak profiles. This approach is shown to be capable of correctly discarding many of the EC candidates which were proposed by commercial EC calculating algorithms. Using this intuitive strategy significantly extends the upper mass range for the successful elucidation of ECs. Copyright 2010 John Wiley & Sons, Ltd.

  12. Bronchoalveolar carcinoma (adenocarcinoma) mimicking recurrent bacterial community-acquired pneumonia (CAP).

    PubMed

    Cunha, Burke A; Syed, Uzma; Mikail, Nardeen

    2012-01-01

    Depending on the community-acquired pneumonia (CAP) pathogen, host factors, and immune status, CAPs resolve on chest x-rays at different rates. CAPs that resolve more slowly than expected, or not at all, are termed "slowly or non-resolving CAPs." In contrast, recurrent CAPs may be due to host defense defects (eg, multiple myelomas) or post-obstructive bronchogenic carcinomas. There are a variety of noninfectious disorders that may mimic CAPs on chest x-ray: alveolar hemorrhage, pulmonary drug reactions, radiation pneumonitis, Wegener's granulomatosis, bronchiolitis obliterans organizing pneumonia, bronchogenic carcinomas, and lymphomas. Noninfectious mimics of recurrent CAPs include congestive heart failure, pulmonary emboli, infarctions, sarcoidosis, and systemic lupus erythematosus pneumonitis. We present the case of a middle-aged man who presented with recurrent right middle lobe and right lower lobe CAPs. Diagnostic bronchoscopy showed no bronchial obstruction, but open lung biopsy showed bronchoalveolar carcinoma (well-differentiated adenocarcinoma). Bronchoalveolar carcinomas presenting as post-obstructive or recurrent CAPs are rare because the spread is along tissue planes and not endobronchially. The case described demonstrates a rare cause of bronchogenic carcinoma mimicking recurrent CAP. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Developing DIII-D To Prepare For ITER And The Path To Fusion Energy

    NASA Astrophysics Data System (ADS)

    Buttery, Richard; Hill, David; Solomon, Wayne; Guo, Houyang; DIII-D Team

    2017-10-01

    DIII-D pursues the advancement of fusion energy through scientific understanding and discovery of solutions. Research targets two key goals. First, to prepare for ITER we must resolve how to use its flexible control tools to rapidly reach Q =10, and develop the scientific basis to interpret results from ITER for fusion projection. Second, we must determine how to sustain a high performance fusion core in steady state conditions, with minimal actuators and a plasma exhaust solution. DIII-D will target these missions with: (i) increased electron heating and balanced torque neutral beams to simulate burning plasma conditions (ii) new 3D coil arrays to resolve control of transients (iii) off axis current drive to study physics in steady state regimes (iv) divertors configurations to promote detachment with low upstream density (v) a reactor relevant wall to qualify materials and resolve physics in reactor-like conditions. With new diagnostics and leading edge simulation, this will position the US for success in ITER and a unique knowledge to accelerate the approach to fusion energy. Supported by the US DOE under DE-FC02-04ER54698.

  14. The CubeSat Imaging X-ray Solar Spectrometer (CubIXSS) Mission Concept

    NASA Astrophysics Data System (ADS)

    Caspi, Amir; Shih, Albert Y.; Warren, Harry; DeForest, Craig; Laurent, Glenn Thomas; Schwartz, Richard A.; Woods, Thomas N.; Mason, James; Palo, Scott; Steslicki, Marek; Sylwester, Janusz; Gburek, Szymon; Mrozek, Tomasz; Kowalinski, Miroslaw; Torre, Gabriele; Crowley, Geoffrey; Schattenburg, Mark

    2017-08-01

    Solar soft X-ray (SXR) observations provide important diagnostics of plasma heating, during solar flares and quiescent times. Spectrally- and temporally-resolved measurements are crucial for understanding the dynamics, origins, and evolution of these energetic processes, providing probes both into the temperature distributions and elemental compositions of hot plasmas; spatially-resolved measurements are critical for understanding energy transport and mass flow. A better understanding of the thermal plasma improves our understanding of the relationships between particle acceleration, plasma heating, and the underlying release of magnetic energy during reconnection. We introduce a new proposed small satellite mission, the CubeSat Imaging X-ray Solar Spectrometer (CubIXSS), to measure spectrally- and spatially-resolved SXRs from the quiescent and flaring Sun from a 6U CubeSat platform in low-Earth orbit during a nominal 1-year mission. CubIXSS includes the Amptek X123-FastSDD silicon drift detector, a low-noise, commercial off-the-shelf (COTS) instrument enabling solar SXR spectroscopy from ~0.5 to ~30 keV with ~0.15 keV FWHM spectral resolution with low power, mass, and volume requirements. Multiple detectors and tailored apertures provide sensitivity to a wide range of solar conditions, optimized for a launch during solar minimum. The precise spectra from these instruments will provide detailed measurements of the coronal temperature distribution and elemental abundances from the quiet Sun to active regions and flares. CubIXSS also includes a novel spectro-spatial imager -- the first ever solar imager on a CubeSat -- utilizing a custom pinhole camera and Chandra-heritage X-ray transmission diffraction grating to provide spatially- resolved, full-Sun imaging spectroscopy from ~0.1 to ~10 keV, with ~25 arcsec and ~0.1 Å FWHM spatial and spectral resolutions, respectively. MOXSI’s unique capabilities enable SXR spectroscopy and temperature diagnostics of individual active regions and flares. Through its groundbreaking new measurements, CubIXSS will improve our physical understanding of thermal plasma processes and impulsive energy release in the solar corona, from quiet Sun to solar flares.

  15. Psychology Problem Classification for Children and Youth.

    ERIC Educational Resources Information Center

    Minnesota Systems Research, Inc., Washington, DC.

    The development of Psychology Problem Classification is an early step in the direction of providing a uniform nomenclature for classifying the needs and problems of children and youth. There are many potential uses for a diagnostic classification and coding system. The two most important uses for the practitioner are problem identification and…

  16. Rational suicide: an impoverished self-transformation.

    PubMed

    Maris, R

    1982-01-01

    The normal human condition is such that even with the best that life can offer suicide is understandable. Life is short, often painful, unpredictable, and lonely. In addition the lives of some individuals are in effect "suicidal careers" in that the harshness of normal life is combined for them with extra suicidal catalysts. Suicide makes sense. Minimally suicide resolves the life problem for the suicide. At the same time suicide is an impoverished self-transformation. Life, as trying and despairing as it can be, is still all we have, The suicide resolves the life problem by obliterating life itself, rather than by transforming self, history, and society. The suicide gives his or her life back inappropriately. In this sense no suicide is ever rational.

  17. Shape-shifting corals: Molecular markers show morphology is evolutionarily plastic in Porites

    PubMed Central

    Forsman, Zac H; Barshis, Daniel J; Hunter, Cynthia L; Toonen, Robert J

    2009-01-01

    Background Corals are notoriously difficult to identify at the species-level due to few diagnostic characters and variable skeletal morphology. This 'coral species problem' is an impediment to understanding the evolution and biodiversity of this important and threatened group of organisms. We examined the evolution of the nuclear ribosomal internal transcribed spacer (ITS) and mitochondrial markers (COI, putative control region) in Porites, one of the most taxonomically challenging and ecologically important genera of reef-building corals. Results Nuclear and mitochondrial markers were congruent, clearly resolving many traditionally recognized species; however, branching and mounding varieties were genetically indistinguishable within at least two clades, and specimens matching the description of 'Porites lutea' sorted into three genetically divergent groups. Corallite-level features were generally concordant with genetic groups, although hyper-variability in one group (Clade I) overlapped and obscured several others, and Synarea (previously thought to be a separate subgenus) was closely related to congeners despite its unique morphology. Scanning electron microscopy revealed subtle differences between genetic groups that may have been overlooked previously as taxonomic characters. Conclusion This study demonstrates that the coral skeleton can be remarkably evolutionarily plastic, which may explain some taxonomic difficulties, and obscure underlying patterns of endemism and diversity. PMID:19239678

  18. Automated Segmentation Methods of Drusen to Diagnose Age-Related Macular Degeneration Screening in Retinal Images.

    PubMed

    Kim, Young Jae; Kim, Kwang Gi

    2018-01-01

    Existing drusen measurement is difficult to use in clinic because it requires a lot of time and effort for visual inspection. In order to resolve this problem, we propose an automatic drusen detection method to help clinical diagnosis of age-related macular degeneration. First, we changed the fundus image to a green channel and extracted the ROI of the macular area based on the optic disk. Next, we detected the candidate group using the difference image of the median filter within the ROI. We also segmented vessels and removed them from the image. Finally, we detected the drusen through Renyi's entropy threshold algorithm. We performed comparisons and statistical analysis between the manual detection results and automatic detection results for 30 cases in order to verify validity. As a result, the average sensitivity was 93.37% (80.95%~100%) and the average DSC was 0.73 (0.3~0.98). In addition, the value of the ICC was 0.984 (CI: 0.967~0.993, p < 0.01), showing the high reliability of the proposed automatic method. We expect that the automatic drusen detection helps clinicians to improve the diagnostic performance in the detection of drusen on fundus image.

  19. Iodine-induced hyperthyroidism as combination of different etiologies: an overlooked entity in the elderly.

    PubMed

    Foppiani, Luca; Cascio, Christian; Lo Pinto, Giuliano

    2016-10-01

    Iodine-induced thyrotoxicosis, which raises several diagnostic and therapeutical challenges, is often overlooked. Hyperthyroidism can induce atrial fibrillation, a harmful arrhythmia which can precipitate heart failure and cause stroke. We report the case of an elderly man who was diagnosed with tachyfibrillation secondary to hyperthyroidism. Thyroid hyperfunction was subsequently related both to previous amiodarone therapy (probably mixed form) and the recent use of iodinated contrast medium for computed tomography scan. Thyroid ultrasonography showed a plongeant multinodular goitre. After initial worsening, thyroid function improved slowly but progressively on high-dose thyreostatic therapy combined with steroid therapy; tachyfibrillation caused heart failure and a thrombus in the left atrium, and proved initially resistant to combined antiarrhythmic treatments. Progressive reduction in thyroid hormone levels, together with combined cardiologic therapies, controlled the heart rate, though atrial fibrillation persisted; anticoagulant therapy resolved the atrial thrombus. Alterations in thyroid function are common in amiodarone-treated patients, who therefore require regular hormonal checks. The different forms of amiodarone-induced thyrotoxicosis must be investigated, since they require different therapies, though mixed forms often occur. The superimposition of further iodine excess due to other causes may be catastrophic and cause severe cardiac problems in these patients.

  20. High-speed flow visualization in hypersonic, transonic, and shock tube flows

    NASA Astrophysics Data System (ADS)

    Kleine, H.; Olivier, H.

    2017-02-01

    High-speed flow visualisation has played an important role in the investigations conducted at the Stoßwellenlabor of the RWTH Aachen University for many decades. In addition to applying the techniques of high-speed imaging, this laboratory has been actively developing new or enhanced visualisation techniques and approaches such as various schlieren methods or time-resolved Mach-Zehnder interferometry. The investigated high-speed flows are inherently highly transient, with flow Mach numbers ranging from about M = 0.7 to M = 8. The availability of modern high-speed cameras has allowed us to expand the investigations into problems where reduced reproducibility had so far limited the amount of information that could be extracted from a limited number of flow visualisation records. Following a brief historical overview, some examples of recent studies are given, which represent the breadth of applications in which high-speed imaging has been an essential diagnostic tool to uncover the physics of high-speed flows. Applications include the stability of hypersonic corner flows, the establishment of shock wave systems in transonic airfoil flow, and the complexities of the interactions of shock waves with obstacles of various shapes.

Top