Sample records for resonance imaging replace

  1. Right ventricular volumes assessed by echocardiographic three-dimensional knowledge-based reconstruction compared with magnetic resonance imaging in a clinical setting.

    PubMed

    Neukamm, Christian; Try, Kirsti; Norgård, Gunnar; Brun, Henrik

    2014-01-01

    A technique that uses two-dimensional images to create a knowledge-based, three-dimensional model was tested and compared to magnetic resonance imaging. Measurement of right ventricular volumes and function is important in the follow-up of patients after pulmonary valve replacement. Magnetic resonance imaging is the gold standard for volumetric assessment. Echocardiographic methods have been validated and are attractive alternatives. Thirty patients with tetralogy of Fallot (25 ± 14 years) after pulmonary valve replacement were examined. Magnetic resonance imaging volumetric measurements and echocardiography-based three-dimensional reconstruction were performed. End-diastolic volume, end-systolic volume, and ejection fraction were measured, and the results were compared. Magnetic resonance imaging measurements gave coefficient of variation in the intraobserver study of 3.5, 4.6, and 5.3 and in the interobserver study of 3.6, 5.9, and 6.7 for end-diastolic volume, end-systolic volume, and ejection fraction, respectively. Echocardiographic three-dimensional reconstruction was highly feasible (97%). In the intraobserver study, the corresponding values were 6.0, 7.0, and 8.9 and in the interobserver study 7.4, 10.8, and 13.4. In comparison of the methods, correlations with magnetic resonance imaging were r = 0.91, 0.91, and 0.38, and the corresponding coefficient of variations were 9.4, 10.8, and 14.7. Echocardiography derived volumes (mL/m(2)) were significantly higher than magnetic resonance imaging volumes in end-diastolic volume 13.7 ± 25.6 and in end-systolic volume 9.1 ± 17.0 (both P < .05). The knowledge-based three-dimensional right ventricular volume method was highly feasible. Intra and interobserver variabilities were satisfactory. Agreement with magnetic resonance imaging measurements for volumes was reasonable but unsatisfactory for ejection fraction. Knowledge-based reconstruction may replace magnetic resonance imaging measurements for serial follow-up, whereas magnetic resonance imaging should be used for surgical decision making.

  2. Magnetic resonance imaging of the central nervous system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-02-26

    This report reviews the current applications of magnetic resonance imaging of the central nervous system. Since its introduction into the clinical environment in the early 1980's, this technology has had a major impact on the practice of neurology. It has proved to be superior to computed tomography for imaging many diseases of the brain and spine. In some instances it has clearly replaced computed tomography. It is likely that it will replace myelography for the assessment of cervicomedullary junction and spinal regions. The magnetic field strengths currently used appear to be entirely safe for clinical application in neurology except inmore » patients with cardiac pacemakers or vascular metallic clips. Some shortcomings of magnetic resonance imaging include its expense, the time required for scanning, and poor visualization of cortical bone.« less

  3. Integrated approach to ischemic heart disease. The one-stop shop.

    PubMed

    Kramer, C M

    1998-05-01

    Magnetic resonance imaging is unique in its variety of applications for imaging the cardiovascular system. A thorough assessment of myocardial structure, function, and perfusion; assessment of coronary artery anatomy and flow; and spectroscopic evaluation of cardiac energetics can be readily performed by magnetic resonance imaging. One key to the advancement of cardiac magnetic resonance imaging as a clinical tool in the evaluation, the so called one stop shop. Improvements in magnetic resonance hardware, software, and imaging speed now permit this integrated examination. Cardiac magnetic resonance is a powerful technique with the potential to replace or complement other commonly used techniques in the diagnostic armamentarium of physicians caring for patients with ischemic heart disease.

  4. Accelerating Sequences in the Presence of Metal by Exploiting the Spatial Distribution of Off-Resonance

    PubMed Central

    Smith, Matthew R.; Artz, Nathan S.; Koch, Kevin M.; Samsonov, Alexey; Reeder, Scott B.

    2014-01-01

    Purpose To demonstrate feasibility of exploiting the spatial distribution of off-resonance surrounding metallic implants for accelerating multispectral imaging techniques. Theory Multispectral imaging (MSI) techniques perform time-consuming independent 3D acquisitions with varying RF frequency offsets to address the extreme off-resonance from metallic implants. Each off-resonance bin provides a unique spatial sensitivity that is analogous to the sensitivity of a receiver coil, and therefore provides a unique opportunity for acceleration. Methods Fully sampled MSI was performed to demonstrate retrospective acceleration. A uniform sampling pattern across off-resonance bins was compared to several adaptive sampling strategies using a total hip replacement phantom. Monte Carlo simulations were performed to compare noise propagation of two of these strategies. With a total knee replacement phantom, positive and negative off-resonance bins were strategically sampled with respect to the B0 field to minimize aliasing. Reconstructions were performed with a parallel imaging framework to demonstrate retrospective acceleration. Results An adaptive sampling scheme dramatically improved reconstruction quality, which was supported by the noise propagation analysis. Independent acceleration of negative and positive off-resonance bins demonstrated reduced overlapping of aliased signal to improve the reconstruction. Conclusion This work presents the feasibility of acceleration in the presence of metal by exploiting the spatial sensitivities of off-resonance bins. PMID:24431210

  5. Impact of enzyme replacement therapy on cardiac morphology and function and late enhancement in Fabry's cardiomyopathy.

    PubMed

    Beer, Meinrad; Weidemann, Frank; Breunig, Frank; Knoll, Anita; Koeppe, Sabrina; Machann, Wolfram; Hahn, Dietbert; Wanner, Christoph; Strotmann, Jörg; Sandstede, Jörn

    2006-05-15

    The present study evaluated the evolution of cardiac morphology, function, and late enhancement as a noninvasive marker of myocardial fibrosis, and their inter-relation during enzyme replacement therapy in patients with Fabry's disease using magnetic resonance imaging and color Doppler myocardial imaging. Late enhancement, which was present in up to 50% of patients, was associated with increased left ventricular mass, the failure of a significant regression of hypertrophy during enzyme replacement therapy, and worse segmental myocardial function. Late enhancement may predict the effect of enzyme replacement therapy on left ventricular mass and cardiac function.

  6. The Efficacy of Multiparametric Magnetic Resonance Imaging and Magnetic Resonance Imaging Targeted Biopsy in Risk Classification for Patients with Prostate Cancer on Active Surveillance.

    PubMed

    Recabal, Pedro; Assel, Melissa; Sjoberg, Daniel D; Lee, Daniel; Laudone, Vincent P; Touijer, Karim; Eastham, James A; Vargas, Hebert A; Coleman, Jonathan; Ehdaie, Behfar

    2016-08-01

    We determined whether multiparametric magnetic resonance imaging targeted biopsies may replace systematic biopsies to detect higher grade prostate cancer (Gleason score 7 or greater) and whether biopsy may be avoided based on multiparametric magnetic resonance imaging among men with Gleason 3+3 prostate cancer on active surveillance. We identified men with previously diagnosed Gleason score 3+3 prostate cancer on active surveillance who underwent multiparametric magnetic resonance imaging and a followup prostate biopsy. Suspicion for higher grade cancer was scored on a standardized 5-point scale. All patients underwent a systematic biopsy. Patients with multiparametric magnetic resonance imaging regions of interest also underwent magnetic resonance imaging targeted biopsy. The detection rate of higher grade cancer was estimated for different multiparametric magnetic resonance imaging scores with the 3 biopsy strategies of systematic, magnetic resonance imaging targeted and combined. Of 206 consecutive men on active surveillance 135 (66%) had a multiparametric magnetic resonance imaging region of interest. Overall, higher grade cancer was detected in 72 (35%) men. A higher multiparametric magnetic resonance imaging score was associated with an increased probability of detecting higher grade cancer (Wilcoxon-type trend test p <0.0001). Magnetic resonance imaging targeted biopsy detected higher grade cancer in 23% of men. Magnetic resonance imaging targeted biopsy alone missed higher grade cancers in 17%, 12% and 10% of patients with multiparametric magnetic resonance imaging scores of 3, 4 and 5, respectively. Magnetic resonance imaging targeted biopsies increased the detection of higher grade cancer among men on active surveillance compared to systematic biopsy alone. However, a clinically relevant proportion of higher grade cancer was detected using only systematic biopsy. Despite the improved detection of disease progression using magnetic resonance imaging targeted biopsy, systematic biopsy cannot be excluded as part of surveillance for men with low risk prostate cancer. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Magnetic resonance imaging findings of the pancreas in patients with Shwachman-Diamond syndrome and mutations in the SBDS gene.

    PubMed

    Toiviainen-Salo, Sanna; Raade, Merja; Durie, Peter R; Ip, Wan; Marttinen, Eino; Savilahti, Erkki; Mäkitie, Outi

    2008-03-01

    Pancreatic MRI was evaluated in 14 patients with a clinical diagnosis of Shwachman-Diamond syndrome, and the findings were correlated with Shwachman-Bodian-Diamond gene (SBDS) genotype. The findings suggest that patients with mutations in the SBDS gene have a characteristic magnetic resonance imaging pattern of fat-replaced pancreas and that SBDS mutations are unlikely in patients without this pattern.

  8. Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.

    PubMed

    Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D

    2017-08-01

    The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.

  9. Diagnosis of deep endometriosis: clinical examination, ultrasonography, magnetic resonance imaging, and other techniques.

    PubMed

    Bazot, Marc; Daraï, Emile

    2017-12-01

    The aim of the present review was to evaluate the contribution of clinical examination and imaging techniques, mainly transvaginal sonography and magnetic resonance imaging (MRI) to diagnose deep infiltrating (DE) locations using prisma statement recommendations. Clinical examination has a relative low sensitivity and specificity to diagnose DE. Independently of DE locations, for all transvaginal sonography techniques a pooled sensitivity and specificity of 79% and 94% are observed approaching criteria for a triage test. Whatever the protocol and MRI devices, the pooled sensitivity and specificity for pelvic endometriosis diagnosis were 94% and 77%, respectively. For rectosigmoid endometriosis, pooled sensitivity and specificity of MRI were 92% and 96%, respectively fulfilling criteria of replacement test. In conclusion, advances in imaging techniques offer high sensitivity and specificity to diagnose DE with at least triage value and for rectosigmoid endometriosis replacement value imposing a revision of the concept of laparoscopy as the gold standard. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  10. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    To demonstrate the feasibility of Real-time magnetic resonance imaging (rtMRI) guided transcatheter aortic valve replacement (TAVR) with an active guidewire and an MRI compatible valve delivery catheter system in a swine model. The CoreValve system was minimally modified to be MRI-compatible by replacing the stainless steel components with fluoroplastic resin and high-density polyethylene components. Eight swine weighing 60-90 kg underwent rtMRI-guided TAVR with an active guidewire through a left subclavian approach. Two imaging planes (long-axis view and short-axis view) were used simultaneously for real-time imaging during implantation. Successful deployment was performed without rapid ventricular pacing or cardiopulmonary bypass. Postdeployment images were acquired to evaluate the final valve position in addition to valvular and cardiac function. Our results show that the CoreValve can be easily and effectively deployed through a left subclavian approach using rtMRI guidance, a minimally modified valve delivery catheter system, and an active guidewire. This method allows superior visualization before deployment, thereby allowing placement of the valve with pinpoint accuracy. rtMRI has the added benefit of the ability to perform immediate postprocedural functional assessment, while eliminating the morbidity associated with radiation exposure, rapid ventricular pacing, contrast media renal toxicity, and a more invasive procedure. Use of a commercially available device brings this rtMRI-guided approach closer to clinical reality. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Computed Tomography Perfusion, Magnetic Resonance Imaging, and Histopathological Findings After Laparoscopic Renal Cryoablation: An In Vivo Pig Model.

    PubMed

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole; Pedersen, Bodil Ginnerup; Andersen, Gratien; Høyer, Søren; Borre, Michael

    2017-08-01

    The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention, each animal was randomized to a postoperative follow-up period of 1, 2, or 4 weeks, after which computed tomography perfusion and magnetic resonance imaging scans were performed. Immediately after imaging, open bilateral nephrectomy was performed allowing for histopathological examination of the cryolesions. On computed tomography perfusion and magnetic resonance imaging examinations, rim enhancement was observed in the transition zone of the cryolesion 1week after laparoscopic-assisted cryoablation. This rim enhancement was found to subside after 2 and 4 weeks of follow-up, which was consistent with the microscopic examinations revealing of fibrotic scar tissue formation in the peripheral zone of the cryolesion. On T2 magnetic resonance imaging sequences, a thin hypointense rim surrounded the cryolesion, separating it from the adjacent renal parenchyma. Microscopic examinations revealed hemorrhage and later hemosiderin located in the peripheral zone. No nodular or diffuse contrast enhancement was found in the central zone of the cryolesions at any follow-up stage on neither computed tomography perfusion nor magnetic resonance imaging. On microscopic examinations, the central zone was found to consist of coagulative necrosis 1 week after laparoscopic-assisted cryoablation, which was partially replaced by fibrotic scar tissue 4 weeks following laparoscopic-assisted cryoablation. Both computed tomography perfusion and magnetic resonance imaging found the renal collecting system to be involved at all 3 stages of follow-up, but on microscopic examination, the urothelium was found to be intact in all cases. In conclusion, cryoablation effectively destroyed renal parenchyma, leaving the urothelium intact. Both computed tomography perfusion and magnetic resonance imaging reflect the microscopic findings but with some differences, especially regarding the peripheral zone. Magnetic resonance imaging seems an attractive modality for early postoperative follow-up.

  12. Retrospective review of 50 canine nasal tumours evaluated by low-field magnetic resonance imaging.

    PubMed

    Avner, A; Dobson, J M; Sales, J I; Herrtage, M E

    2008-05-01

    Low-field magnetic resonance imaging machines are being used more often in veterinary practice for the investigation of sinonasal disease. The aim of this retrospective study was to describe and characterise the low-field magnetic resonance imaging features of nasal tumours in dogs. The Queen's Veterinary School Hospital magnetic resonance imaging database (2001-2005) was searched for dogs with a magnetic resonance imaging diagnosis of a nasal tumour. Fifty cases with histological diagnosis of nasal tumour were found. The appearance and extent of the nasal tumour as well as the involvement of adjacent anatomic structures were examined against a checklist. The most common magnetic resonance imaging findings were as follows. (1) Soft tissue mass replacing the destroyed nasal conchae and/or ethmoturbinates (98 per cent of cases). (2) Nasal septum destruction (68 per cent of cases). (3) Retained secretions with or without mass caudally in frontal sinuses (62 per cent of cases). (4) Nasal/frontal bone destruction (52 per cent of cases). Low-field magnetic resonance imaging allowed differentiation of tumour tissue from retained secretions or necrotic tissue. Magnetic resonance imaging was invaluable in assessing the extension of the tumour into the maxillary recesses, caudal recesses, nasopharynx, adjacent bones and cranial cavity. The tumour often extended caudally into the frontal sinuses, nasopharynx and perhaps most importantly into the caudal recesses. Tumour extension into the cranial cavity was not common (16 per cent), and only three of these cases showed neurological signs. However, 54 per cent of cases showed focal meningeal (dural) hyperintensity, although the significance of this is unclear. A significant difference (P<0.05) in tumour signal intensity between the sarcomas and carcinomas was found. The use of a low-field magnetic resonance imaging technique is excellent for the diagnosis and determination of extent of sinonasal tumours.

  13. Takotsubo-like syndrome triggered by fludrocortisone overdose for Addison's disease: a case report.

    PubMed

    Campean, Radu; Hasun, Matthias; Stöllberger, Claudia; Bucher, Johannes; Finsterer, Josef; Schnack, Christoph; Weidinger, Franz

    2016-10-12

    Reversible left ventricular dysfunction, also termed Takotsubo cardiomyopathy, is rarely reported in Addison's disease after initiation of hormone replacement therapy. The pathogenesis of this cardiomyopathy is unknown. A 41-year-old white woman with a history of autoimmune Hashimoto thyroiditis diagnosed 3 years earlier and acute adrenal insufficiency diagnosed 3 weeks earlier presented with new onset of heart failure New York Heart Association class IV, which had started shortly after initiation of hormone replacement therapy with hydrocortisone 20 mg/day and fludrocortisone 0.3 mg/day. Nine days before admission she had collapsed because of dizziness and had a cerebral concussion and open fracture of her nasal bone, however, no further investigations were carried out at that time. A physical examination revealed leg edema, tachycardia, tachypnea, bilateral basal crepitations, and blood pressure 110/70 mmHg. An electrocardiogram showed sinus tachycardia, low voltage, negative T-waves in V 5 and V 6 and a corrected QT interval of 590 ms. Echocardiography revealed a reduced left ventricular systolic function with an ejection fraction of 30 %, and septal, apical, and anterior wall akinesia. Cardiac magnetic resonance imaging showed relative enhancement of gadolinium, indicating hyperemia and capillary leakage, and no myocardial scars. Because of the improvement in her cardiac function, lack of cardiovascular risk factors, and lack of signs for ischemia on magnetic resonance imaging, no coronary angiography was carried out. The results of sellar and renal magnetic resonance imaging were normal. Her troponin T was slightly elevated. Bisoprolol and ramipril were started. Her fludrocortisone dose was reduced to 0.05 mg/day. Her electrocardiogram and systolic function, documented by echocardiography and magnetic resonance imaging, normalized within 6 months. Although we could not exclude coronary artery disease by coronary angiography, her clinical course and instrumental findings suggest Takotsubo cardiomyopathy of the apical type. Fludrocortisone overdosage and increased myocardial vulnerability due to cortisol deficiency might be pathogenetic factors, whereas myocarditis is unlikely. When hormone replacement in patients with Addison's disease is initiated, cardiac function should be monitored by electrocardiogram and echocardiography.

  14. Avascular necrosis of the femoral head presenting as trochanteric bursitis.

    PubMed Central

    Mandell, B F

    1990-01-01

    Five patients are described with avascular necrosis of the femoral head who presented with ipsilateral trochanteric bursitis, in the absence of clearcut hip joint disease. Avascular necrosis was indicated by magnetic resonance imaging. It is suggested that clinical trochanteric bursitis, especially when refractory to local corticosteroid treatment, may be the initial sign of hip disease. In the patient with risk factor(s) for avascular necrosis that diagnosis should be considered and evaluated with appropriate studies, such as magnetic resonance imaging, to prevent weight bearing at an early stage and permit possible surgical decompression in the hope of postponing or obviating the need for total hip replacement. PMID:2241294

  15. Magnetically engineered smart thin films: toward lab-on-chip ultra-sensitive molecular imaging.

    PubMed

    Hassan, Muhammad A; Saqib, Mudassara; Shaikh, Haseeb; Ahmad, Nasir M; Elaissari, Abdelhamid

    2013-03-01

    Magnetically responsive engineered smart thin films of nanoferrites as contrast agent are employed to develop surface based magnetic resonance imaging to acquire simple yet fast molecular imaging. The work presented here can be of significant potential for future lab-on-chip point-of-care diagnostics from the whole blood pool on almost any substrates to reduce or even prevent clinical studies involve a living organism to enhance the non-invasive imaging to advance the '3Rs' of work in animals-replacement, refinement and reduction.

  16. Vanishing White Matter Disease: A Review with Focus on Its Genetics

    ERIC Educational Resources Information Center

    Pronk, Jan C.; van Kollenburg, Barbara; Scheper, Gert C.; van der Knaap, Marjo S.

    2006-01-01

    Leukoencephalopathy with vanishing white matter (VWM) is an autosomal recessive brain disorder, most often with a childhood onset. Magnetic resonance imaging and spectroscopy indicate that, with time, increasing amounts of cerebral white matter vanish and are replaced by fluid. Autopsy confirms white matter rarefaction and cystic degeneration. The…

  17. Improved olefinic fat suppression in skeletal muscle DTI using a magnitude-based dixon method.

    PubMed

    Burakiewicz, Jedrzej; Hooijmans, Melissa T; Webb, Andrew G; Verschuuren, Jan J G M; Niks, Erik H; Kan, Hermien E

    2018-01-01

    To develop a method of suppressing the multi-resonance fat signal in diffusion-weighted imaging of skeletal muscle. This is particularly important when imaging patients with muscular dystrophies, a group of diseases which cause gradual replacement of muscle tissue by fat. The signal from the olefinic fat peak at 5.3 ppm can significantly confound diffusion-tensor imaging measurements. Dixon olefinic fat suppression (DOFS), a magnitude-based chemical-shift-based method of suppressing the olefinic peak, is proposed. It is verified in vivo by performing diffusion tensor imaging (DTI)-based quantification in the lower leg of seven healthy volunteers, and compared to two previously described fat-suppression techniques in regions with and without fat contamination. In the region without fat contamination, DOFS produces similar results to existing techniques, whereas in muscle contaminated by subcutaneous fat signal moved due to the chemical shift artefact, it consistently showed significantly higher (P = 0.018) mean diffusivity (MD). Because fat presence lowers MD, this suggests improved fat suppression. DOFS offers superior fat suppression and enhances quantitative measurements in the muscle in the presence of fat. DOFS is an alternative to spectral olefinic fat suppression. Magn Reson Med 79:152-159, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Cranial MRI in a young child with cochlear implants after bilateral magnet removal.

    PubMed

    Helbig, Silke; Stöver, Timo; Burck, Iris; Kramer, Sabine

    2017-12-01

    A young bilateral cochlear implant (CI) user required magnetic resonance imaging (MRI) to determine the cause of hydrocephalus. The images obtained with the CIs in place were not diagnostically useful due to large artefacts generated by the CI magnets. We obtained useful images by bilaterally explanting the CI-magnets and replacing them with non-magnetic placeholder dummies then conducted the imaging. The artefact in the new images was greatly reduced and the images were diagnostically useful. Lastly, we explanted the dummies and reimplanted the CI-magnets. This procedure should be useful to obtain useful images in CI users. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [Different aspects of magnetic resonance imaging of muscles between dermatomyositis and polymyositis].

    PubMed

    Miranda, Sofia Silveira de Castro; Alvarenga, Daniel; Rodrigues, João Carlos; Shinjo, Samuel Katsuyuki

    2014-01-01

    Although dermatomyositis (DM) and polymyositis (PM) share many clinical features in common, they have distinct pathophysiological and histological features. It is possible that these distinctions reflect also macroscopically, for example, in muscle alterations seen in magnetic resonance images (MRI). To compare simultaneously the MRI of various muscle compartments of the thighs of adult DM and PM. The present study is a cross-sectional that included, between 2010 and 2013, 11 newly diagnosed DM and 11 PM patients (Bohan and Peter's criteria, 1975), with clinical and laboratory activity. They were valued at RM thighs, T1 and T2 with fat suppression, 1.5 T MRI scanner sequences. The mean age at the time of MRI, the time between onset of symptoms and the realization of the MRI distribution of sex and drug therapy were comparable between the two groups (p>0.050). Concerning the MRI, muscle edema was significantly found in DM, and mainly in the proximal region of the muscles. The area of fat replacement was found predominantly in PM. The partial fat replacement area occurred mainly in the medial and distal region, whereas the total fat replacement area occurred mainly in the distal muscles. There was no area of muscle fibrosis. DM and PM have different characteristics on MRI muscles, alike pathophysiological and histological distinctions. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  20. Imaging the Endometrium: A Pictorial Essay.

    PubMed

    Sadro, Claudia T

    2016-08-01

    Female gynaecologic conditions arising from the endometrium are common and depend on a woman's age, her menstrual history, and the use of medications such as hormone replacement and tamoxifen. Both benign and malignant conditions affect the endometrium. Benign conditions must be distinguished from malignant and premalignant conditions. The most commonly used imaging modality for evaluating the endometrium is pelvic ultrasound with transabdominal and transvaginal techniques. Additional imaging methods include hysterosonography and magnetic resonance imaging. This pictorial essay will review the normal and abnormal appearance of the endometrium and diagnostic algorithms to evaluate abnormal vaginal bleeding and abnormal endometrial thickness. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Osteochondral transplantation of the talus: long-term clinical and magnetic resonance imaging evaluation.

    PubMed

    Imhoff, Andreas B; Paul, Jochen; Ottinger, Benjamin; Wörtler, Klaus; Lämmle, Lena; Spang, Jeffrey; Hinterwimmer, Stefan

    2011-07-01

    Osteochondral lesions of the ankle are a common injury after ankle sprains, especially in young and active patients. The Osteochondral Autograft Transfer System (OATS) is the only 1-step surgical technique designed to replace the entire osteochondral unit. This study was conducted to evaluate the long-term clinical and radiographic outcomes of the OATS procedure for the talus and compare the results of patients who have had prior surgical interventions with patients for whom OATS represents the primary surgical treatment. Case series; Level of evidence, 4. The authors retrospectively analyzed 26 talus OATS procedures (25 patients) with an average follow-up of 84 months (range, 53-124 months); 9 patients had OATS as a second surgical intervention. The patients completed the American Orthopaedic Foot & Ankle Society (AOFAS) and Tegner scores plus the visual analog scale (VAS) preoperatively and at follow-up. Magnetic resonance imaging examinations were conducted on a 1.5-T whole-body magnet that assessed transplant congruency, adjacent surface of the talus, the corresponding distal tibia, and joint effusion. The authors found significant increases for the AOFAS score (50 to 78 points, P < .01) and the Tegner score (3.1 to 3.7, P < .05) and a significant decrease for the VAS (7.8 to 1.5, P < .01) from preoperative to postoperative. Patients with normal integration or minor incongruity of the transplant on magnetic resonance imaging (81%) had significantly better AOFAS scores (P = .03). Other magnetic resonance imaging criteria did not predict clinical results. Patients for whom OATS represented a second procedure had significantly worse clinical AOFAS and Tegner scores plus a higher VAS. Long-term clinical and magnetic resonance imaging results after osteochondral transplantation are good and patients significantly benefit from this surgery. Magnetic resonance imaging should not be a routine control but appears to be indicated when clinical symptoms persist after osteochondral transplantation.

  2. Real-time control system for adaptive resonator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flath, L; An, J; Brase, J

    2000-07-24

    Sustained operation of high average power solid-state lasers currently requires an adaptive resonator to produce the optimal beam quality. We describe the architecture of a real-time adaptive control system for correcting intra-cavity aberrations in a heat capacity laser. Image data collected from a wavefront sensor are processed and used to control phase with a high-spatial-resolution deformable mirror. Our controller takes advantage of recent developments in low-cost, high-performance processor technology. A desktop-based computational engine and object-oriented software architecture replaces the high-cost rack-mount embedded computers of previous systems.

  3. Non-invasive assessment of pulsatile intracranial pressure with phase-contrast magnetic resonance imaging

    PubMed Central

    Lindstrøm, Erika Kristina; Vatnehol, Svein Are Sirirud; Mardal, Kent-André; Emblem, Kyrre Eeg; Eide, Per Kristian

    2017-01-01

    Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of “true” normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43). Pulse pressure gradients were also similar in patients and healthy controls (P = .26), and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97). Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate marker for intracranial pressure pulsations. PMID:29190788

  4. Non-invasive assessment of pulsatile intracranial pressure with phase-contrast magnetic resonance imaging.

    PubMed

    Ringstad, Geir; Lindstrøm, Erika Kristina; Vatnehol, Svein Are Sirirud; Mardal, Kent-André; Emblem, Kyrre Eeg; Eide, Per Kristian

    2017-01-01

    Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of "true" normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43). Pulse pressure gradients were also similar in patients and healthy controls (P = .26), and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97). Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate marker for intracranial pressure pulsations.

  5. Robot-assisted real-time magnetic resonance image-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    Real-time magnetic resonance imaging (rtMRI)-guided transcatheter aortic valve replacement (TAVR) offers improved visualization, real-time imaging, and pinpoint accuracy with device delivery. Unfortunately, performing a TAVR in a MRI scanner can be a difficult task owing to limited space and an awkward working environment. Our solution was to design a MRI-compatible robot-assisted device to insert and deploy a self-expanding valve from a remote computer console. We present our preliminary results in a swine model. We used an MRI-compatible robotic arm and developed a valve delivery module. A 12-mm trocar was inserted in the apex of the heart via a subxiphoid incision. The delivery device and nitinol stented prosthesis were mounted on the robot. Two continuous real-time imaging planes provided a virtual real-time 3-dimensional reconstruction. The valve was deployed remotely by the surgeon via a graphic user interface. In this acute nonsurvival study, 8 swine underwent robot-assisted rtMRI TAVR for evaluation of feasibility. Device deployment took a mean of 61 ± 5 seconds. Postdeployment necropsy was performed to confirm correlations between imaging and actual valve positions. These results demonstrate the feasibility of robotic-assisted TAVR using rtMRI guidance. This approach may eliminate some of the challenges of performing a procedure while working inside of an MRI scanner, and may improve the success of TAVR. It provides superior visualization during the insertion process, pinpoint accuracy of deployment, and, potentially, communication between the imaging device and the robotic module to prevent incorrect or misaligned deployment. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  6. Gadolinium-free MR in coarctation-can contrast-enhanced MR angiography be replaced?

    PubMed

    Kalmar, Peter I; Koestenberger, Martin; Marterer, Robert; Tschauner, Sebastian; Sorantin, Erich

    2016-01-01

    To determine the difference in vessel measurements, signal-to-noise ratio (SNR), and voxel size between contrast-enhanced and noncontrast magnetic resonance techniques in patients with coarctation of the aorta (CoA). In 39 patients, vessel size, SNR, and voxel size were compared in cine magnetic resonance imaging (MRI), gadolinium-free magnetic resonance angiography (Gd-free MRA), and contrast-enhanced MRA (ce-MRA). There was no significant difference in measurement and SNR, but there was a significant difference in voxel size (P<.001). Our results show that, in CoA patients, monitoring of vessel size using cine MRI and Gd-free MRA is equivalent to ce-MRA while being less invasive. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Multi-detector CT angiography of the aortic valve—Part 2: disease specific findings

    PubMed Central

    Ganeshan, Arul

    2014-01-01

    The aortic valve and adjacent structures should be routinely evaluated on all thoracic cross-sectional imaging studies. Echocardiography and magnetic resonance imaging (MRI) are the main imaging techniques used for assessment of the aortic valve and related pathology but multi-detector computed tomography (MDCT) can offer valuable complimentary information in some clinical scenarios. MDCT is the definite means of assessing aortic valvular calcification, acute aortic syndrome and for non-invasive assessment of the coronary arteries. MDCT also has an emerging role in the planning and follow-up of trans-catheter aortic valve replacement. This article reviews the spectrum of aortic valve disease highlighting the key MDCT imaging features. PMID:25202663

  8. The knee: Surface-coil MR imaging at 1. 5 T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beltran, J.; Noto, A.M.; Mosure, J.C.

    1986-06-01

    Seven normal knees (in five volunteers) and seven injured knees (in seven patients) were examined by high-resolution magnetic resonance (MR) imaging at 1.5 T with a surface coil. Seven medial meniscal tears, three anterior cruciate ligament tears, one posterior cruciate ligament avulsion, an old osteochondral fracture, femoral condylar chondro-malacia, and one case of semimembranous tendon reinsertion were identified. MR images correlated well with recent double-contrast arthrograms or results of surgery. All tears were identified in both the sagittal and coronal planes. Because of its ability to demonstrate small meniscal lesions and ligamentous injuries readily, MR imaging with a surface coilmore » may eventually replace the more invasive arthrography.« less

  9. Multi-Modality Imaging in the Evaluation and Treatment of Mitral Regurgitation.

    PubMed

    Bouchard, Marc-André; Côté-Laroche, Claudia; Beaudoin, Jonathan

    2017-10-13

    Mitral regurgitation (MR) is frequent and associated with increased mortality and morbidity when severe. It may be caused by intrinsic valvular disease (primary MR) or ventricular deformation (secondary MR). Imaging has a critical role to document the severity, mechanism, and impact of MR on heart function as selected patients with MR may benefit from surgery whereas other will not. In patients planned for a surgical intervention, imaging is also important to select candidates for mitral valve (MV) repair over replacement and to predict surgical success. Although standard transthoracic echocardiography is the first-line modality to evaluate MR, newer imaging modalities like three-dimensional (3D) transesophageal echocardiography, stress echocardiography, cardiac magnetic resonance (CMR), and computed tomography (CT) are emerging and complementary tools for MR assessment. While some of these modalities can provide insight into MR severity, others will help to determine its mechanism. Understanding the advantages and limitations of each imaging modality is important to appreciate their respective role for MR assessment and help to resolve eventual discrepancies between different diagnostic methods. With the increasing use of transcatheter mitral procedures (repair or replacement) for high-surgical-risk patients, multimodality imaging has now become even more important to determine eligibility, preinterventional planning, and periprocedural guidance.

  10. Plasmon-resonant nanorods as multimodal agents for two-photon luminescent imaging and photothermal therapy

    NASA Astrophysics Data System (ADS)

    Huff, Terry B.; Hansen, Matthew N.; Tong, Ling; Zhao, Yan; Wang, Haifeng; Zweifel, Daniel A.; Cheng, Ji-Xin; Wei, Alexander

    2007-02-01

    Plasmon-resonant gold nanorods have outstanding potential as multifunctional agents for image-guided therapies. Nanorods have large absorption cross sections at near-infrared (NIR) frequencies, and produce two-photon luminescence (TPL) when excited by fs-pulsed laser irradiation. The TPL signals can be detected with single-particle sensitivity, enabling nanorods to be imaged in vivo while passing through blood vessels at subpicomolar concentrations. Furthermore, cells labeled with nanorods become highly susceptible to photothermal damage when irradiated at plasmon resonance, often resulting in a dramatic blebbing of the cell membrane. However, the straightforward application of gold nanorods for cell-specific labeling is obstructed by the presence of CTAB, a cationic surfactant carried over from nanorod synthesis which also promotes their nonspecific uptake into cells. Careful exchange and replacement of CTAB can be achieved by introducing oligoethyleneglycol (OEG) units capable of chemisorption onto nanorod surfaces by in situ dithiocarbamate formation, a novel method of surface functionalization. Nanorods with a dense coating of methyl-terminated OEG chains are shielded from nonspecific cell uptake, whereas nanorods functionalized with folate-terminated OEG chains accumulate on the surface of tumor cells overexpressing their cognate receptor, with subsequent delivery of photoinduced cell damage at low laser fluence.

  11. Genetic engineered molecular imaging probes for applications in cell therapy: emphasis on MRI approach

    PubMed Central

    Cho, In K; Wang, Silun; Mao, Hui; Chan, Anthony WS

    2016-01-01

    Recent advances in stem cell-based regenerative medicine, cell replacement therapy, and genome editing technologies (i.e. CRISPR-Cas 9) have sparked great interest in in vivo cell monitoring. Molecular imaging promises a unique approach to noninvasively monitor cellular and molecular phenomena, including cell survival, migration, proliferation, and even differentiation at the whole organismal level. Several imaging modalities and strategies have been explored for monitoring cell grafts in vivo. We begin this review with an introduction describing the progress in stem cell technology, with a perspective toward cell replacement therapy. The importance of molecular imaging in reporting and assessing the status of cell grafts and their relation to the local microenvironment is highlighted since the current knowledge gap is one of the major obstacles in clinical translation of stem cell therapy. Based on currently available imaging techniques, we provide a brief discussion on the pros and cons of each imaging modality used for monitoring cell grafts with particular emphasis on magnetic resonance imaging (MRI) and the reporter gene approach. Finally, we conclude with a comprehensive discussion of future directions of applying molecular imaging in regenerative medicine to emphasize further the importance of correlating cell graft conditions and clinical outcomes to advance regenerative medicine. PMID:27766183

  12. Non-invasive imaging of atherosclerosis regression with magnetic resonance to guide drug development.

    PubMed

    Raggi, Paolo; Baldassarre, Damiano; Day, Simon; de Groot, Eric; Fayad, Z A

    2016-08-01

    Slowing of progression and inducing the regression of atherosclerosis with medical therapy have been shown to be associated with an extensive reduction in risk of cardiovascular events. This proof of concept was obtained with invasive angiographic studies but these are, for obvious reasons, impractical for sequential investigations. Non-invasive imaging has henceforth replaced the more cumbersome invasive studies and has proven extremely valuable in numerous occasions. Because of excellent reproducibility and no radiation exposure, magnetic resonance imaging (MRI) has become the non-invasive method of choice to assess the efficacy of anti-atherosclerotic drugs. The high accuracy of this technology is particularly helpful in rare diseases where the small number of affected patients makes the conduct of outcome-trials in large cohorts impractical. With MRI it is possible to assess the extent, as well as the composition, of atherosclerotic plaques and this further enhances the utility of this technology. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Diagnosis and quantification of fibrosis, steatosis, and hepatic siderosis through multiparametric magnetic resonance imaging.

    PubMed

    Stoopen-Rometti, M; Encinas-Escobar, E R; Ramirez-Carmona, C R; Wolpert-Barraza, E; Kimura-Hayama, E; Sosa-Lozano, L A; Favila, R; Kimura-Fujikami, Y; Saavedra-Abril, J A; Loaeza-Del Castillo, A

    The presence of liver fibrosis is the common denominator in numerous chronic liver diseases that can progress to fibrosis and hepatocellular carcinoma. Most important, with respect to frequency, are viral hepatitis and non-alcoholic fatty liver disease, the prevalence of which is increasing in epidemic proportions. Liver biopsy, albeit imperfect, continues to be the criterion standard, but in many clinical situations tends to be replaced with noninvasive imaging methods. The aim of the present article was to describe our imaging department experience with magnetic resonance elastography and to analyze and discuss recently published results in gastroenterology, hepatology, and radiology from other authors in the literature, complemented with a PubMed search covering the last 10 years. Magnetic resonance elastography is an efficacious, noninvasive method with results that are concordant with liver biopsy. It is superior to ultrasound elastography because it evaluates a much greater volume of hepatic tissue and shows the often heterogeneous lesion distribution. The greatest advantage of the magnetic resonance protocol described is the fact that it quantifies fibrosis, fat content, and iron content in the same 25min examination specifically directed for that purpose, resulting in a favorable cost-benefit ratio for the patient and/or institution. Copyright © 2016 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Shopping around for hospital services: a comparison of the United States and Canada.

    PubMed

    Bell, C M; Crystal, M; Detsky, A S; Redelmeier, D A

    1998-04-01

    Historical comparisons indicate that US hospitals are more expensive than Canadian hospitals, but health care system reform might have changed the relative costs and timeliness of health care in the 2 countries. To estimate the price and convenience of selected hospital services in the United States and Canada for patients in 1997 had they paid out-of-pocket. Cross-sectional telephone survey conducted May 1996 to April 1997. The 2 largest acute care general hospitals from every city in the United States and Canada with a population greater than 500000. Each hospital was telephoned and asked their price and waiting time for 7 services: magnetic resonance imaging of the head without gadolinium; a screening mammogram; a 12-lead electrocardiogram; a prothrombin time measurement; a session of hemodialysis; a screening colonoscopy; and a total knee replacement. Waiting times were measured in days until earliest appointment and charges were converted to American currency. Overall, 48 US and 18 Canadian hospitals were surveyed. Median waiting times were significantly shorter in American hospitals for 4 services, particularly a magnetic resonance imaging of the head (3 days vs 150 days; P<.001). Median charges were significantly higher in American hospitals for 6 services, particularly for a total knee replacement ($26805 vs $10651; P<.001). Individual services showed no association between shorter waiting times and higher prices within each country, with the exception of a total knee replacement in the United States. US hospitals still provide higher prices and faster care than Canadian hospitals for patients who pay out-of-pocket.

  15. [A case of cerebral fat embolism after artificial bone replacement operation for femoral head fracture].

    PubMed

    Kontani, Satoru; Nakamura, Akinobu; Tokumi, Hiroshi; Hirose, Genjirou

    2014-01-01

    A 83 years old woman was slipped and injured with right femoral neck fracture. After three days from the fracture, she underwent an artificial head bone replacement operation. Immediately after surgery, she complained of chest discomfort, nausea and dyspnea. A few hours later, she became comatose. Brain CT showed no abnormality and clinical diagnosis of heart failure was made without pulmonary embolism on enhanced chest CT. Magnetic resonance imaging (MRI) of the brain next day showed multiple small patchy hyperintense lesion in bilateral hemispheres on diffusion-weighted images (DWI), producing a "star field pattern''. Based on Criteria of Gurd, this patient had one major criterion and four minor criteria. And according to the Criteria of Schonfeld, this patient had 5 points, consistent with clinical diagnosis of fat embolism. Because of these criteria, she was diagnosed as cerebral fat embolism syndrome. We started supported care and edaravon. Two weeks after surgery, her condition recovered and remaind to stuporous state even six month after surgery. We experienced a typical case of cerebral fat embolism, after bone surgery with diagnostic findings on MRI-DWI. Diagnosis of cerebral fat embolism syndrome requires a history of long bone fracture and/or replacing surgery with typical finding on MRI images, such as "star field pattern''.

  16. MR Image Based Approach for Metal Artifact Reduction in X-Ray CT

    PubMed Central

    2013-01-01

    For decades, computed tomography (CT) images have been widely used to discover valuable anatomical information. Metallic implants such as dental fillings cause severe streaking artifacts which significantly degrade the quality of CT images. In this paper, we propose a new method for metal-artifact reduction using complementary magnetic resonance (MR) images. The method exploits the possibilities which arise from the use of emergent trimodality systems. The proposed algorithm corrects reconstructed CT images. The projected data which is affected by dental fillings is detected and the missing projections are replaced with data obtained from a corresponding MR image. A simulation study was conducted in order to compare the reconstructed images with images reconstructed through linear interpolation, which is a common metal-artifact reduction technique. The results show that the proposed method is successful in reducing severe metal artifacts without introducing significant amount of secondary artifacts. PMID:24302860

  17. Four-dimensional respiratory motion-resolved whole heart coronary MR angiography.

    PubMed

    Piccini, Davide; Feng, Li; Bonanno, Gabriele; Coppo, Simone; Yerly, Jérôme; Lim, Ruth P; Schwitter, Juerg; Sodickson, Daniel K; Otazo, Ricardo; Stuber, Matthias

    2017-04-01

    Free-breathing whole-heart coronary MR angiography (MRA) commonly uses navigators to gate respiratory motion, resulting in lengthy and unpredictable acquisition times. Conversely, self-navigation has 100% scan efficiency, but requires motion correction over a broad range of respiratory displacements, which may introduce image artifacts. We propose replacing navigators and self-navigation with a respiratory motion-resolved reconstruction approach. Using a respiratory signal extracted directly from the imaging data, individual signal-readouts are binned according to their respiratory states. The resultant series of undersampled images are reconstructed using an extradimensional golden-angle radial sparse parallel imaging (XD-GRASP) algorithm, which exploits sparsity along the respiratory dimension. Whole-heart coronary MRA was performed in 11 volunteers and four patients with the proposed methodology. Image quality was compared with that obtained with one-dimensional respiratory self-navigation. Respiratory-resolved reconstruction effectively suppressed respiratory motion artifacts. The quality score for XD-GRASP reconstructions was greater than or equal to self-navigation in 80/88 coronary segments, reaching diagnostic quality in 61/88 segments versus 41/88. Coronary sharpness and length were always superior for the respiratory-resolved datasets, reaching statistical significance (P < 0.05) in most cases. XD-GRASP represents an attractive alternative for handling respiratory motion in free-breathing whole heart MRI and provides an effective alternative to self-navigation. Magn Reson Med 77:1473-1484, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Dark Field Microscopy for Analytical Laboratory Courses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Augspurger, Ashley E; Stender, Anthony S; Marchuk, Kyle

    2014-06-10

    An innovative and inexpensive optical microscopy experiment for a quantitative analysis or an instrumental analysis chemistry course is described. The students have hands-on experience with a dark field microscope and investigate the wavelength dependence of localized surface plasmon resonance in gold and silver nanoparticles. Students also observe and measure individual crystal growth during a replacement reaction between copper and silver nitrate. The experiment allows for quantitative, qualitative, and image data analyses for undergraduate students.

  19. Ferumoxytol MRA for transcatheter aortic valve replacement planning with renal insufficiency.

    PubMed

    Kallianos, Kimberly; Henry, Travis S; Yeghiazarians, Yerem; Zimmet, Jeffrey; Shunk, Kendrick A; Tseng, Elaine E; Mahadevan, Vaikom; Hope, Michael D

    2017-03-15

    Computed tomography angiography (CTA) is the test of choice for pre-procedure imaging of transcatheter aortic valve replacement (TAVR) candidates. The iodinated contrast required, however, increases the risk of renal dysfunction in patients with pre-existing renal failure. Ferumoxytol is a magnetic resonance imaging (MRI) contrast agent that can be used with renal failure. Its long vascular resonance time allows gated MRA sequences that approach CTA in image quality. We present respiratory and cardiac gated MRA enabled by ferumoxytol that can be post-processed in an analogous fashion to CTA. Seven patients with renal failure presenting for TAVR were imaged with respiratory and cardiac gated MRA at 3T using ferumoxtyol for contrast. Aortic annulus, root and peripheral access dimensions were calculated in a fashion identical to that used for CTA. Of these, 6 patients underwent a TAVR procedure and 5 had intraoperative valve assessment with transesophageal echocardiograph (TEE) using standard clinical protocols that employed both two- and three-dimensional techniques. Good correlation between MRA aortic annulus measurements and those from TEE were shown in 5 patients with mean annulus area of 392.4mm 2 (290-470 range) versus 374.1mm 2 (285-440 range), with a pairwise correlation coefficient of 0.92, p=0.029. All patients received Sapien valve implants (one 20mm, three 23mm, and two 26mm valves). Access decisions were guided by MRA with no complications. Annulus sizing resulted in no greater than trace/mild aortic regurgitation in all patients. Ferumoxytol MRA is a safe alternative to CTA in patients with renal failure for pre-TAVR analysis of the aortic root and peripheral access. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Muscle MR Imaging in Tubular Aggregate Myopathy

    PubMed Central

    Beltrame, Valeria; Ortolan, Paolo; Coran, Alessandro; Zanato, Riccardo; Gazzola, Matteo; Frigo, Annachiara; Bello, Luca; Pegoraro, Elena; Stramare, Roberto

    2014-01-01

    Purpose To evaluate with Magnetic Resonance (MR) the degree of fatty replacement and edematous involvement in skeletal muscles in patients with Tubular Aggregate Myopathy (TAM). To asses the inter-observer agreement in evaluating muscle involvement and the symmetry index of fatty replacement. Materials and Methods 13 patients were evaluated by MR to ascertain the degree of fatty replacement (T1W sequences) according to Mercuri's scale, and edema score (STIR sequences) according to extent and site. Results Fatty replacement mainly affects the posterior superficial compartment of the leg; the anterior compartment is generally spared. Edema was generally poor and almost only in the superficial compartment of the leg. The inter-observer agreement is very good with a Krippendorff's coefficient >0.9. Data show a total symmetry in the muscular replacement (McNemar-Bowker test with p = 1). Conclusions MR reveals characteristic muscular involvement, and is a reproducible technique for evaluation of TAM. There may also be a characteristic involvement of the long and short heads of the biceps femoris. It is useful for aimed biopsies, diagnostic hypotheses and evaluation of disease progression. PMID:24722334

  1. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment.

    PubMed

    Spencer, Brian A; Mont, Michael A; McGrath, Mike S; Boyd, Bradley; Mitrick, Michael F

    2009-12-01

    New technology using magnetic resonance imaging (MRI) allows the surgeon to place total knee replacement components into each patient's pre-arthritic natural alignment. This study evaluated the initial intra-operative experience using this technique. Twenty-one patients had a sagittal MRI of their arthritic knee to determine component placement for a total knee replacement. Cutting guides were machined to control all intra-operative cuts. Intra-operative events were recorded and these knees were compared to a matching cohort of the senior surgeon's previous 30 conventional total knee replacements. Post-operative scanograms were obtained from each patient and coronal alignment was compared to previous studies using conventional and computer-assisted techniques. There were no intra-operative or acute post-operative complications. There were no differences in blood loss and there was a mean decrease in operative time of 14% compared to a cohort of patients with conventional knee replacements. The average deviation from the mechanical axis was 1.2 degrees of varus, which was comparable to previously reported conventional and computer-assisted techniques. Custom-fit total knee replacement appeared to be a safe procedure for uncomplicated cases of osteoarthritis.

  2. Resonant antenna probes for tip-enhanced infrared near-field microscopy.

    PubMed

    Huth, Florian; Chuvilin, Andrey; Schnell, Martin; Amenabar, Iban; Krutokhvostov, Roman; Lopatin, Sergei; Hillenbrand, Rainer

    2013-03-13

    We report the development of infrared-resonant antenna probes for tip-enhanced optical microscopy. We employ focused-ion-beam machining to fabricate high-aspect ratio gold cones, which replace the standard tip of a commercial Si-based atomic force microscopy cantilever. Calculations show large field enhancements at the tip apex due to geometrical antenna resonances in the cones, which can be precisely tuned throughout a broad spectral range from visible to terahertz frequencies by adjusting the cone length. Spectroscopic analysis of these probes by electron energy loss spectroscopy, Fourier transform infrared spectroscopy, and Fourier transform infrared near-field spectroscopy corroborates their functionality as resonant antennas and verifies the broad tunability. By employing the novel probes in a scattering-type near-field microscope and imaging a single tobacco mosaic virus (TMV), we experimentally demonstrate high-performance mid-infrared nanoimaging of molecular absorption. Our probes offer excellent perspectives for optical nanoimaging and nanospectroscopy, pushing the detection and resolution limits in many applications, including nanoscale infrared mapping of organic, molecular, and biological materials, nanocomposites, or nanodevices.

  3. The neural code of thoughts and feelings. Comment on "Topodynamics of metastable brains" by Arturo Tozzi et al.

    NASA Astrophysics Data System (ADS)

    Jaušovec, Norbert

    2017-07-01

    Recently the number of theories trying to explain the brain - cognition - behavior relation has been increased. Promoted on the one hand by the development of sophisticated brain imaging techniques, such as functional magnetic resonance imaging (fMRI) and diffusion tensor imaging (DTI), and on the other, by complex computational models based on chaos and graph theory. But has this really advanced our understanding of the brain-behavior relation beyond Descartes's dualistic mind body division? One could critically argue that replacing the pineal body with extracellular electric fields represented in the electroencephalogram (EEG) as rapid transitional processes (RTS), combined with algebraic topology and dubbed brain topodynamics [1] is just putting lipstick on an outmoded evergreen.

  4. Vegetation attached to the elephant trunk.

    PubMed

    Tanaka, Akiko; Sakamoto, Toshihito; Okada, Kenji; Okita, Yutaka

    2013-09-01

    The elephant trunk technique is used as a standard method in the approach to staged repair of extensive thoracic aneurysms. Here, we present a rare case of a graft infection, in which vegetation was attached to the distal end of the elephant trunk. A 36-year old male who had undergone total arch replacement with elephant trunk installation for type A aortic dissection was readmitted for high-grade fever. At the time of admission, Osler's nodules were present and brain magnetic resonance imaging showed multiple small emboli and haemorrhages. Transoesophageal echocardiography could not locate any sign of infection within the cardiac chambers, but disclosed vegetation attached to the elephant trunk. He underwent successful emergent graft replacement of the lesion, and no recurrence of the infection has been observed.

  5. Applicability of McDonald 2010 and Magnetic Resonance Imaging in Multiple Sclerosis (MAGNIMS) 2016 Magnetic Resonance Imaging Criteria for the Diagnosis of Multiple Sclerosis in Sri Lanka.

    PubMed

    Gamage, Sujani Madhurika Kodagoda; Wijeweera, Indunil; Wijesinghe, Priyangi; Adikari, Sanjaya Bandara; Fink, Katharina; Sominanda, Herath Mudiyanselage Ajith

    2018-05-31

    The magnetic resonance imaging in multiple sclerosis (MAGNIMS) group recently proposed guidelines to replace the existing dissemination-in-space criteria in McDonald 2010 magnetic resonance imaging (MRI) criteria for diagnosing multiple sclerosis. There has been insufficient research regarding their applicability in Asians. Objective of this study was to determine the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of McDonald 2010 and MAGNIMS 2016 MRI criteria with the aim of verifying their applicability in Sri Lankan patients. Patients with clinically isolated syndrome diagnosed by consultant neurologists were recruited from five major neurology centers. Baseline and follow-up MRI scans were performed within 3 months from the initial presentation and at one year after baseline MRI, respectively. McDonald 2010 and MAGNIMS 2016 MRI criteria were applied to all MRI scans. Patients were followed-up for 2 years to assess the conversion to clinically definite multiple sclerosis (CDMS). The sensitivity, specificity, accuracy, PPV, and NPV for predicting the conversion to CDMS were calculated. Forty-two of 66 patients converted to CDMS. Thirty-seven fulfilled the McDonald 2010 MRI criteria, and 33 converted to CDMS. MAGNIMS 2016 MRI criteria were fulfilled by 29, with 28 converting to CDMS. The sensitivity, specificity, accuracy, PPV, and NPV were 78%, 83%, 64%, 89%, and 69%, respectively, for the McDonald 2010 criteria, and 67%, 96%, 77%, 96%, and 62% for the MAGNIMS 2016 MRI criteria. MAGNIMS 2016 MRI criteria were superior to McDonald 2010 MRI criteria in specificity, accuracy, and PPV, but inferior in sensitivity and NPV. Copyright © 2018 Korean Neurological Association.

  6. Nanoscale imaging of photocurrent enhancement by resonator array photovoltaic coatings.

    PubMed

    Ha, Dongheon; Yoon, Yohan; Zhitenev, Nikolai B

    2018-04-06

    Nanoscale surface patterning commonly used to increase absorption of solar cells can adversely impact the open-circuit voltage due to increased surface area and recombination. Here, we demonstrate absorptivity and photocurrent enhancement using silicon dioxide (SiO 2 ) nanosphere arrays on a gallium arsenide (GaAs) solar cell that do not require direct surface patterning. Due to the combined effects of thin-film interference and whispering gallery-like resonances within nanosphere arrays, there is more than 20% enhancement in both absorptivity and photocurrent. To determine the effect of the resonance coupling between nanospheres, we perform a scanning photocurrent microscopy based on a near-field scanning optical microscopy measurement and find a substantial local photocurrent enhancement. The nanosphere-based antireflection coating (ARC), made by the Meyer rod rolling technique, is a scalable and a room-temperature process; and, can replace the conventional thin-film-based ARCs requiring expensive high-temperature vacuum deposition.

  7. Nanoscale imaging of photocurrent enhancement by resonator array photovoltaic coatings

    NASA Astrophysics Data System (ADS)

    Ha, Dongheon; Yoon, Yohan; Zhitenev, Nikolai B.

    2018-04-01

    Nanoscale surface patterning commonly used to increase absorption of solar cells can adversely impact the open-circuit voltage due to increased surface area and recombination. Here, we demonstrate absorptivity and photocurrent enhancement using silicon dioxide (SiO2) nanosphere arrays on a gallium arsenide (GaAs) solar cell that do not require direct surface patterning. Due to the combined effects of thin-film interference and whispering gallery-like resonances within nanosphere arrays, there is more than 20% enhancement in both absorptivity and photocurrent. To determine the effect of the resonance coupling between nanospheres, we perform a scanning photocurrent microscopy based on a near-field scanning optical microscopy measurement and find a substantial local photocurrent enhancement. The nanosphere-based antireflection coating (ARC), made by the Meyer rod rolling technique, is a scalable and a room-temperature process; and, can replace the conventional thin-film-based ARCs requiring expensive high-temperature vacuum deposition.

  8. [Role of cardiac magnetic resonance in cardiac involvement of Fabry disease].

    PubMed

    Serra, Viviana M; Barba, Miguel Angel; Torrá, Roser; Pérez De Isla, Leopoldo; López, Mónica; Calli, Andrea; Feltes, Gisela; Torras, Joan; Valverde, Victor; Zamorano, José L

    2010-09-04

    Fabry disease is a hereditary disorder. Clinical manifestations are multisystemic. The majority of the patients remain undiagnosed until late in life, when alterations could be irreversible. Early detection of cardiac symptoms is of major interest in Fabry's disease (FD) in order to gain access to enzyme replacement therapy. Echo-Doppler tissular imaging (TDI) has been used as a cardiologic early marker in FD. This study is intended to determine whether the cardiac magnetic resonance is as useful tool as TDI for the early detection of cardiac affectation in FD. Echocardiography, tissue Doppler and Cardio magnetic resonance was performed in 20 patients with confirmed Fabry Disease. Left ventricular hypertrophy was defined as septum and left ventricular posterior wall thickness ≥12 mm. An abnormal TDI velocity was defined as (Sa), (Ea) and/or (Aa) velocities <8 cm/s at either the septal or lateral corner. Late phase gadolinium-enhanced images sequences were obtained using magnetic resonance. Twenty patients included in the study were divided into three groups: 1. Those without left ventricular hypertrophy nor tissue Doppler impairment 2. Those without left ventricular hypertrophy and tissue Doppler impairment 3. Those with left ventricular hypertrophy and Tissue Doppler impairment. Late gadolinium enhancement was found in only one patient, who has already altered DTI and LVH. Tissue Doppler imaging (TDI) is the only diagnostic tool able to provide early detection of cardiac affectation in patients with FD. Magnetic resonance provides information of the disease severity in patients with LVH, but can not be used as an early marker of cardiac disease in patients with FD. However MRI could be of great value for diagnostic stratification. Copyright © 2009 Elsevier España, S.L. All rights reserved.

  9. SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, R.; Giri, Shankar; VA Medical Center at Jackson, Mississippi

    2014-06-01

    Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planningmore » system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation.« less

  10. Importance of increased intraosseous pressure in the development of osteonecrosis of the femoral head: implications for treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hungerford, D.S.; Lennox, D.W.

    1985-10-01

    Early diagnosis of osteonecrosis by radiograph, bone scan, CT scan, magnetic resonance imaging (MRI), intraosseous pressure measurement, or intraosseous venogram can lead to early successful treatment. For early (Ficat stages I and II) osteonecrosis of the hip, core decompression can provide diagnostic confirmation and pain relief and may prevent progression of disease. For more advanced disease (Ficat stages II and IV), osteotomy, endoprosthetic or bipolar prosthetic replacement, total hip arthroplasty, and arthrodesis are surgical options.86 references.

  11. Accuracy of magnetic resonance imaging, magnetic resonance arthrography and computed tomography for the detection of chondral lesions of the knee.

    PubMed

    Smith, Toby O; Drew, Benjamin T; Toms, Andoni P; Donell, Simon T; Hing, Caroline B

    2012-12-01

    To assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and computed tomography arthrography (CTA) for the detection of chondral lesions of the patellofemoral and tibiofemoral joints. A review of published and unpublished literature sources was conducted on 22nd September 2011. All studies assessing the diagnostic test accuracy (sensitivity/specificity) of MRI or MRA or CTA for the assessment of adults with chondral (cartilage) lesions of the knee (tibiofemoral/patellofemoral joints) with surgical comparison (arthroscopic or open) as the reference test were included. Data were analysed through meta-analysis. Twenty-seven studies assessing 2,592 knees from 2,509 patients were included. The findings indicated that whilst presenting a high specificity (0.95-0.99), the sensitivity of MRA, MRI and CTA ranged from 0.70 to 0.80. MRA was superior to MRI and CTA for the detection of patellofemoral joint chondral lesions and that higher field-strength MRI scanner and grade four lesions were more accurately detected compared with lower field-strength and grade one lesions. There appeared no substantial difference in diagnostic accuracy between the interpretation from musculoskeletal and general radiologists when undertaking an MRI review of tibiofemoral and patellofemoral chondral lesions. Specialist radiological imaging is specific for cartilage disease in the knee but has poorer sensitivity to determine the therapeutic options in this population. Due to this limitation, there remains little indication to replace the 'gold-standard' arthroscopic investigation with MRI, MRA or CTA for the assessment of adults with chondral lesions of the knee. II.

  12. Sex, Aging, and Preexisting Cerebral Ischemic Disease in Patients With Aortic Stenosis

    PubMed Central

    Wang, Ping; Acker, Michael A.; Bilello, Michel; Melhem, Elias R.; Stambrook, Elizabeth; Ratcliffe, Sarah J.; Floyd, Thomas F.

    2011-01-01

    Background Patients undergoing cardiac surgery have a high frequency of preexisting cerebral ischemic lesions, the presence of which appears to predict cognitive sequelae. Patients undergoing aortic valve replacement for aortic stenosis (AS) incur an exceptionally high risk for perioperative cerebral ischemia. The extreme risk in this subgroup may arise from the preexisting burden of cerebral ischemic disease. We tested the hypotheses that increasing age, female sex, coronary artery disease, and the severity of AS are predictive of the severity of preexisting cerebral ischemic lesions. Methods A total of 95 subjects were included in this study. Subjects were imaged on 1.5 Tesla magnetic resonance imaging scanners to obtain multimodal image sets which were used for the automatic segmentation of cerebral lesion volume. The dependence of lesion volume upon age, sex, coronary artery disease, and the severity of AS were tested. Results The results demonstrate a strong correlation between aging, female sex, and white matter and ischemia-like lesion volume in patients with aortic stenosis. Conclusions Women and those of advanced age presenting for aortic valve replacement for AS may incur a particularly high risk for postoperative neurologic sequelae due to an exceptional preexisting burden of cerebral ischemic disease. PMID:20868818

  13. Variation in uterus position prior to brachytherapy of the cervix: A case report.

    PubMed

    Georgescu, M T; Anghel, R

    2017-01-01

    Rationale: brachytherapy is administered in the treatment of patients with locally advanced cervical cancer following chemoradiotherapy. Lack of local anatomy evaluation prior to this procedure might lead to the selection of an inappropriate brachytherapy applicator, increasing the risk of side effects (e.g. uterus perforation, painful procedure ...). Objective: To assess the movement of the uterus and cervix prior to brachytherapy in patients with gynecological cancer, in order to select the proper type of brachytherapy applicator. Also we wanted to promote the replacement of the plain X-ray brachytherapy with the image-guided procedure. Methods and results: We presented the case of a 41-year-old female diagnosed with a biopsy that was proven cervical cancer stage IIIB. At diagnosis, the imaging studies identified an anteverted uterus. The patient underwent preoperative chemoradiotherapy. Prior to brachytherapy, the patient underwent a pelvic magnetic resonance imaging (MRI), which identified a displacement of the uterus in the retroverted position. Discussion: A great variety of brachytherapy applicators is available nowadays. Major changes in uterus position and lack of evaluation prior to brachytherapy might lead to a higher rate of incidents during this procedure. Also, by using orthogonal simulation and bidimensional (2D) treatment planning, brachytherapy would undoubtedly fail to treat the remaining tumoral tissue. This is the reason why we proposed the implementation of a prior imaging of the uterus and computed tomography (CT)/ MRI-based simulation in the brachytherapy procedure. Abbreviations: MRI = magnetic resonance imaging, CT = computed tomography, CTV = clinical target volume, DVH = dose-volume histogram, EBRT = external beam radiotherapy, GTV = gross tumor volume, Gy = Gray (unit), ICRU = International Commission of Radiation Units, IGRT = image guided radiotherapy, IM = internal margin, IMRT = image modulated radiotherapy, ITV = internal target volume, MRI = magnetic resonance imaging, OAR = organs at risk, PTV = planning target volume, QUANTEC = Quantitative Analyses of Normal Tissue Effects in the Clinic.

  14. Pituitary metastasis of hepatocellular carcinoma presenting with panhypopituitarism: a case report.

    PubMed

    Tanaka, Tomoko; Hiramatsu, Katsushi; Nosaka, Takuto; Saito, Yasushi; Naito, Tatsushi; Takahashi, Kazuto; Ofuji, Kazuya; Matsuda, Hidetaka; Ohtani, Masahiro; Nemoto, Tomoyuki; Suto, Hiroyuki; Yamamoto, Tatsuya; Kimura, Hirohiko; Nakamoto, Yasunari

    2015-11-06

    Metastasis to the pituitary gland is extremely rare and is often detected incidentally by symptoms associated with endocrine dysfunction. Breast and lung cancer are the most common primary metastasizing to pituitary gland. Metastasis from hepatocellular carcinoma to the pituitary gland is extremely rare, with only 10 cases having been previously reported. We present here the first case of pituitary metastasis of hepatocellular carcinoma presenting with panhypopituitarism diagnosed by magnetic resonance imaging. We report the case of an 80-year-old Japanese woman who presented with the sudden onset of hypotension and bradycardia after having previously been diagnosed with hepatocellular carcinoma. Based on low levels of pituitary hormones, she was diagnosed with panhypopituitarism caused by metastasis of the hepatocellular carcinoma to the pituitary gland. Magnetic resonance imaging with arterial spin-labeling was effective in the differential diagnosis of the intrasellar tumor. The patient died despite hormone replacement therapy because of hypovolemic shock. Metastasis to the pituitary gland causes various non-specific symptoms, so it is difficult to diagnose. The present case emphasizes the importance of diagnostic imaging in identifying these metastases. Clinicians should consider the possibility of pituitary metastasis in patients with malignant tumors who demonstrate hypopituitarism.

  15. Voxel-based correlation between coregistered single-photon emission computed tomography and dynamic susceptibility contrast magnetic resonance imaging in subjects with suspected Alzheimer disease.

    PubMed

    Cavallin, L; Axelsson, R; Wahlund, L O; Oksengard, A R; Svensson, L; Juhlin, P; Wiberg, M Kristoffersen; Frank, A

    2008-12-01

    Current diagnosis of Alzheimer disease is made by clinical, neuropsychologic, and neuroimaging assessments. Neuroimaging techniques such as magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) could be valuable in the differential diagnosis of Alzheimer disease, as well as in assessing prognosis. To compare SPECT and MRI in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer disease (AD). 24 patients, eight with AD, 10 with MCI, and six controls, were investigated with SPECT using (99m)Tc-hexamethylpropyleneamine oxime (HMPAO, Ceretec; GE Healthcare Ltd., Little Chalsont UK) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a contrast-enhancing gadobutrol formula (Gadovist; Bayer Schering Pharma, Berlin, Germany). Voxel-based correlation between coregistered SPECT and DSC-MR images was calculated. Region-of-interest (ROI) analyses were then performed in 24 different brain areas using brain registration and analysis of SPECT studies (BRASS; Nuclear Diagnostics AB, Stockholm, Sweden) on both SPECT and DSC-MRI. Voxel-based correlation between coregistered SPECT and DSC-MR showed a high correlation, with a mean correlation coefficient of 0.94. ROI analyses of 24 regions showed significant differences between the control group and AD patients in 10 regions using SPECT and five regions in DSC-MR. SPECT remains superior to DSC-MRI in differentiating normal from pathological perfusion, and DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer disease.

  16. Targeted post-mortem computed tomography cardiac angiography: proof of concept.

    PubMed

    Saunders, Sarah L; Morgan, Bruno; Raj, Vimal; Robinson, Claire E; Rutty, Guy N

    2011-07-01

    With the increasing use and availability of multi-detector computed tomography and magnetic resonance imaging in autopsy practice, there has been an international push towards the development of the so-called near virtual autopsy. However, currently, a significant obstacle to the consideration as to whether or not near virtual autopsies could one day replace the conventional invasive autopsy is the failure of post-mortem imaging to yield detailed information concerning the coronary arteries. To date, a cost-effective, practical solution to allow high throughput imaging has not been presented within the forensic literature. We present a proof of concept paper describing a simple, quick, cost-effective, manual, targeted in situ post-mortem cardiac angiography method using a minimally invasive approach, to be used with multi-detector computed tomography for high throughput cadaveric imaging which can be used in permanent or temporary mortuaries.

  17. Plain magnetic resonance imaging as an alternative in evaluating inflammation and bowel damage in inflammatory bowel disease--a prospective comparison with conventional magnetic resonance follow-through.

    PubMed

    Jesuratnam-Nielsen, Kayalvily; Løgager, Vibeke B; Rezanavaz-Gheshlagh, Bijan; Munkholm, Pia; Thomsen, Henrik S

    2015-05-01

    To compare prospectively the diagnostic accuracy of magnetic resonance imaging (MRI) without use of contrast medium orally or intravenously (plain MRI) with magnetic resonance follow-through (MRFT) in patients with inflammatory bowel disease (IBD). Plain MRI was carried out in addition to MRFT, to which the patients were referred. All patients underwent both examinations on the same day. For the evaluation, the bowel was divided into nine segments. Two radiologists, blinded to clinical findings, evaluated bowel wall thickness, diffusion weighted imaging (DWI), and other inflammatory changes in each bowel segments. Further, hyperenhancement of the bowel was also evaluated in MRFT. A total of 100 patients (40 males and 60 females; median age: 38.5; range: 19-90) were enrolled; 44 with Crohn's disease (CD), 25 with ulcerative colitis (UC), 24 with IBD unclassified (IBD-U), and 7 had other diagnosis. Sensitivity, specificity, and accuracy in CD ranged 50-86%, 93-94%, and 91-92% for wall thickening and 49-82%, 85-93%, and 84-89% for DWI, respectively. Sensitivity, specificity, and accuracy in UC range 0-40%, 87-100%, and 80-100% for wall thickening and 0-52%, 83-94% and 76-92% for DWI, respectively. The κ values for bowel wall thickening, DWI, and mural hyperenhancement were detected with fair agreement (κ = 0.26-0.39) at both MRI examinations, whereas only bowel wall thickening in MRFT were detected with moderate agreement (κ = 0.47) Conclusion. Plain MRI cannot currently replace MRFT in the workup of patients with IBD. Further research on plain MRI is needed to improve the protocol.

  18. Compact orthogonal NMR field sensor

    DOEpatents

    Gerald, II, Rex E.; Rathke, Jerome W [Homer Glen, IL

    2009-02-03

    A Compact Orthogonal Field Sensor for emitting two orthogonal electro-magnetic fields in a common space. More particularly, a replacement inductor for existing NMR (Nuclear Magnetic Resonance) sensors to allow for NMR imaging. The Compact Orthogonal Field Sensor has a conductive coil and a central conductor electrically connected in series. The central conductor is at least partially surrounded by the coil. The coil and central conductor are electrically or electro-magnetically connected to a device having a means for producing or inducing a current through the coil and central conductor. The Compact Orthogonal Field Sensor can be used in NMR imaging applications to determine the position and the associated NMR spectrum of a sample within the electro-magnetic field of the central conductor.

  19. The early and midterm function of decellularized aortic valve allografts.

    PubMed

    da Costa, Francisco D A; Costa, Ana Claudia B A; Prestes, Roberta; Domanski, Ana Carolina; Balbi, Eduardo Mendel; Ferreira, Andreia D A; Lopes, Sergio Veiga

    2010-12-01

    This study evaluates the early and midterm results of decellularized aortic valve allografts (DAVA) as an aortic valve replacement. Between October 2005 and February 2010, 41 patients, 28 of whom were male, with a median age of 34 years (range, 0.1 to 71), had aortic valve replacement with DAVA. Decellularization was obtained with a 0.1% sodium dodecyl sulfate solution. Postoperative evaluation was performed with serial echocardiograms, magnetic resonance imaging, and multislice computed tomography studies to evaluate valve hemodynamics, allograft conduit dimensions, and calcification scores. There were 3 early deaths and 1 late death, with a mean follow-up of 19 months (range, 1 to 53). There was 1 reoperation due to a failed mitral valve repair. By echocardiography in all patients, the median immediate postoperative peak gradient was 7 mm Hg (range, 1 to 26 mm Hg), and at last follow-up it was 4 mm Hg (range, 1 to 16 mm Hg); valvular regurgitation was graded as none or trivial in all but 1 patient, who had a regurgitation graded as mild to moderate. By magnetic resonance imaging (n = 4), mean root dimensions were stable at the annulus (24 mm), sinus of Valsalva (33 mm), and sinotubular junction (28 mm). By computed tomography (n = 22), there was only discrete conduit calcification (median calcium score 63 Hounsfield units [HU]; range, 0 to 894 HU) to 3 years of follow-up. Conduit biopsy in the patient who underwent reoperation demonstrated well-preserved wall structure, absence of calcification, and limited in vivo host repopulation. The early and midterm results with DAVA demonstrated stable structural integrity, low rate of calcification, and adequate hemodynamics. Although longer periods of observation are necessary, DAVA appears to be a promising alternative for aortic valve replacement in selected patients. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Aiming for a shorter rheumatoid arthritis MRI protocol: can contrast-enhanced MRI replace T2 for the detection of bone marrow oedema?

    PubMed

    Stomp, Wouter; Krabben, Annemarie; van der Heijde, Désirée; Huizinga, Tom W J; Bloem, Johan L; van der Helm-van Mil, Annette H M; Reijnierse, Monique

    2014-10-01

    To determine whether T1 post-gadolinium chelate images (T1Gd) can replace T2-weighted images (T2) for evaluating bone marrow oedema (BME), thereby allowing a shorter magnetic resonance imaging (MRI) protocol in rheumatoid arthritis (RA). In 179 early arthritis patients and 43 advanced RA patients, wrist and metacarpophalangeal joints were examined on a 1.5-T extremity MRI system with a standard protocol (coronal T1, T2 fat-saturated and coronal and axial T1 fat-saturated after Gd). BME was scored according to OMERACT RAMRIS by two observers with and without T2 images available. Agreement was assessed using intraclass correlation coefficients (ICCs) for semi-quantitative scores and test characteristics with T2 images as reference. Agreement between scores based on T2 and T1Gd images was excellent ICC (0.80-0.99). At bone level, sensitivity and specificity of BME on T1Gd compared to T2 were high for both patient groups and both readers (all ≥80 %). T1Gd and T2 images are equally suitable for evaluating BME. Because contrast is usually administered to assess (teno)synovitis, a short MRI protocol of T1 and T1Gd is sufficient in RA. • Bone marrow oedema scores are equal on T2 and T1-Gd-chelate enhanced sequences. • Agreement between scores based on T2 and T1-Gd-chelate images was excellent. • Sensitivity and specificity for presence of bone marrow oedema were high. • A short protocol without T2 images suffices in rheumatoid arthritis patients.

  1. 3D Fast Spin Echo T2-weighted Contrast for Imaging the Female Cervix

    NASA Astrophysics Data System (ADS)

    Vargas Sanchez, Andrea Fernanda

    Magnetic Resonance Imaging (MRI) with T2-weighted contrast is the preferred modality for treatment planning and monitoring of cervical cancer. Current clinical protocols image the volume of interest multiple times with two dimensional (2D) T2-weighted MRI techniques. It is of interest to replace these multiple 2D acquisitions with a single three dimensional (3D) MRI acquisition to save time. However, at present the image contrast of standard 3D MRI does not distinguish cervical healthy tissue from cancerous tissue. The purpose of this thesis is to better understand the underlying factors that govern the contrast of 3D MRI and exploit this understanding via sequence modifications to improve the contrast. Numerical simulations are developed to predict observed contrast alterations and to propose an improvement. Improvements of image contrast are shown in simulation and with healthy volunteers. Reported results are only preliminary but a promising start to establish definitively 3D MRI for cervical cancer applications.

  2. Endometrioid adenocarcinoma arising in adenomyosis: elucidation by periodic magnetic resonance imaging evaluations.

    PubMed

    Motohara, Kenichi; Tashiro, Hironori; Ohtake, Hideyuki; Saito, Fumitaka; Ohba, Takashi; Katabuchi, Hidetaka

    2008-06-01

    There are several case reports of adenocarcinomas developing within adenomyosis. However, there is no report demonstrating the natural course from adenomyosis to adenocarcinoma. We report a patient (a 41-year-old Japanese woman) who was observed every 6 months after being diagnosed with adenomyosis at our University Hospital. Although she went through menopause at age 51, she occasionally complained subsequently of abnormal genital bleeding. Eleven years after the initial diagnosis, endometrial cytology revealed the presence of malignant cells. Pelvic magnetic resonance imaging (MRI) demonstrated replacement of the adenomyotic lesion by a poorly demarcated lesion, compared to the findings on prior MRI. Consequently, we performed a modified radical hysterectomy and pelvic lymph node dissection, under a presumptive diagnosis of adenocarcinoma arising in adenomyosis. Histological diagnosis revealed an endometrioid adenocarcinoma (G3) transformed from adenomyotic epithelium, which was classified, according to the International Federation of Gynecology and Obstetrics, as stage Ic, pT1cN0M0. In this patient, periodic MRI evaluations, in conjunction with pathological examination, identified the transformation from adenomyosis to adenocarcinoma.

  3. Serial magnetic resonance imaging of metal-on-metal total hip replacements. Follow-up of a cohort of 28 mm Ultima TPS THRs.

    PubMed

    Ebreo, D; Bell, P J; Arshad, H; Donell, S T; Toms, A; Nolan, J F

    2013-08-01

    Metal artefact reduction (MAR) MRI is now widely considered to be the standard for imaging metal-on-metal (MoM) hip implants. The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended cross-sectional imaging for all patients with symptomatic MoM bearings. This paper describes the natural history of MoM disease in a 28 mm MoM total hip replacement (THR) using MAR MRI. Inclusion criteria were patients with MoM THRs who had not been revised and had at least two serial MAR MRI scans. All examinations were reported by an experienced observer and classified as A (normal), B (infection) or C1-C3 (mild, moderate, severe MoM-related abnormalities). Between 2002 and 2011 a total of 239 MRIs were performed on 80 patients (two to four scans per THR); 63 initial MRIs (61%) were normal. On subsequent MRIs, six initially normal scans (9.5%) showed progression to a disease state; 15 (15%) of 103 THRs with sequential scans demonstrated worsening disease on subsequent imaging. Most patients with a MoM THR who do not undergo early revision have normal MRI scans. Late progression (from normal to abnormal, or from mild to more severe MoM disease) is not common and takes place over several years.

  4. A case of an infant with congenital combined pituitary hormone deficiency and normalized liver histology of infantile cholestasis after hormone replacement therapy.

    PubMed

    Wada, Keisuke; Kobayashi, Hironori; Moriyama, Aisa; Haneda, Yasuhiro; Mushimoto, Yuichi; Hasegawa, Yuki; Onigata, Kazumichi; Kumori, Koji; Ishikawa, Noriyoshi; Maruyama, Riruke; Sogo, Tsuyoshi; Murphy, Lynne; Taketani, Takeshi

    2017-01-01

    Congenital combined pituitary hormone deficiency (CPHD) may present with cholestasis in the neonate or during early infancy. However, its precise mechanism is unknown. A 3-mo-old boy presented with cryptorchidism and hypoplastic scrotum after birth. Neonatal jaundice was noted but temporarily improved with phototherapy. Jaundice recurred at 2 mo of age. Elevated direct bilirubin (D-Bil) and liver dysfunction were found but cholangiography showed no signs of biliary atresia (BA). Liver biopsy findings showed giant cell formation of hepatocytes with hypoplastic bile ducts. Subsequent magnetic resonance imaging (MRI) of the head revealed a hypoplastic pituitary gland with an ectopic posterior lobe, and the patient was diagnosed with congenital CPHD based on decreased secretion of cortisol and GH by the pituitary anterior lobe load test. D-Bil levels promptly improved after hydrocortisone (HDC) replacement. We subsequently began replacement with levothyroxine (L-T 4 ) and GH, and liver histology showed normal interlobular bile ducts at 8 mo old. This is the first case report of proven histological improvement after hormone replacement therapy. This suggested that pituitary-mediated hormones, especially cortisol, might be involved in the development of the bile ducts.

  5. A case of an infant with congenital combined pituitary hormone deficiency and normalized liver histology of infantile cholestasis after hormone replacement therapy

    PubMed Central

    Wada, Keisuke; Kobayashi, Hironori; Moriyama, Aisa; Haneda, Yasuhiro; Mushimoto, Yuichi; Hasegawa, Yuki; Onigata, Kazumichi; Kumori, Koji; Ishikawa, Noriyoshi; Maruyama, Riruke; Sogo, Tsuyoshi; Murphy, Lynne; Taketani, Takeshi

    2017-01-01

    Abstract. Congenital combined pituitary hormone deficiency (CPHD) may present with cholestasis in the neonate or during early infancy. However, its precise mechanism is unknown. A 3-mo-old boy presented with cryptorchidism and hypoplastic scrotum after birth. Neonatal jaundice was noted but temporarily improved with phototherapy. Jaundice recurred at 2 mo of age. Elevated direct bilirubin (D-Bil) and liver dysfunction were found but cholangiography showed no signs of biliary atresia (BA). Liver biopsy findings showed giant cell formation of hepatocytes with hypoplastic bile ducts. Subsequent magnetic resonance imaging (MRI) of the head revealed a hypoplastic pituitary gland with an ectopic posterior lobe, and the patient was diagnosed with congenital CPHD based on decreased secretion of cortisol and GH by the pituitary anterior lobe load test. D-Bil levels promptly improved after hydrocortisone (HDC) replacement. We subsequently began replacement with levothyroxine (L-T4) and GH, and liver histology showed normal interlobular bile ducts at 8 mo old. This is the first case report of proven histological improvement after hormone replacement therapy. This suggested that pituitary-mediated hormones, especially cortisol, might be involved in the development of the bile ducts. PMID:29026274

  6. Resection and Resolution of Bone Marrow Lesions Associated with an Improvement of Pain after Total Knee Replacement: A Novel Case Study Using a 3-Tesla Metal Artefact Reduction MRI Sequence.

    PubMed

    Kurien, Thomas; Kerslake, Robert; Haywood, Brett; Pearson, Richard G; Scammell, Brigitte E

    2016-01-01

    We present our case report using a novel metal artefact reduction magnetic resonance imaging (MRI) sequence to observe resolution of subchondral bone marrow lesions (BMLs), which are strongly associated with pain, in a patient after total knee replacement surgery. Large BMLs were seen preoperatively on the 3-Tesla MRI scans in a patient with severe end stage OA awaiting total knee replacement surgery. Twelve months after surgery, using a novel metal artefact reduction MRI sequence, we were able to visualize the bone-prosthesis interface and found complete resection and resolution of these BMLs. This is the first reported study in the UK to use this metal artefact reduction MRI sequence at 3-Tesla showing that resection and resolution of BMLs in this patient were associated with an improvement of pain and function after total knee replacement surgery. In this case it was associated with a clinically significant improvement of pain and function after surgery. Failure to eradicate these lesions may be a cause of persistent postoperative pain that is seen in up to 20% of patients following TKR surgery.

  7. [Nuclear magnetic resonance of anorectal malformations and persistent postoperative fecal incontinence].

    PubMed

    de Agustín, J C; Alami, H; Lassaletta, L; Gámez, M; Fernández, A; Fraile, E; Alenda, J G; Rollán, V; Utrilla, J G

    1992-07-01

    We review our experience with Magnetic Resonance Imaging (MRI) in the evaluation of 6 patients showing anorectal malformation, and 4 more with persistent postoperative fecal incontinence. Preoperative sagittal, axial and coronal planes were studied with special consideration to the pelvic and vertebral structures. The excellent resolution of MRI allowed accurate identification of the pelvic musculature in all patients, including those with bizarre sacral abnormalities. MRI revealed structural anomalies not detected previously, such as teathering cord, intraspinal lipoma, presacral mass and renal malformation. In our institution, MRI has replaced the CT scan in the study of patients suffering of persistent fecal incontinence. In non operated on cases of anorectal malformations, MRI determines with extraordinary accuracy the location of the rectal atretic pouch, the actual pelvic muscular quality, and the detection of previously unsuspected associated anomalies.

  8. Hypothenar Hammer Syndrome Caused by Recreational Sports Activities and Muscle Anomaly in the Wrist

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreitner, Karl-Friedrich; Dueber, Christoph; Mueller, Lars-Peter

    1996-09-15

    A 34-year-old man with digital ischemia is reported. Angiography revealed thromboembolic occlusions of the proper digital arteries of the index, middle, and ring fingers and a tortuous ulnar artery in Guyon's canal. Though hypothenar hammer syndrome was suspected, there was no relevant occupational history. Magnetic resonance imaging and magnetic resonance angiography demonstrated an anomalous muscular sling around the ulnar artery immediately adjacent to the hook of the hamate. The ulnar artery showed mural thrombi in its tortuous segment. These findings were confirmed during operative exploration. After thrombectomy and embolectomy the involved segment of the ulnar artery was replaced by anmore » autologous vein graft. Postoperatively there was complete resolution of the symptoms. Only during convalescence did it become clear that the patient was a passionate golfer.« less

  9. Image-Based Patient-Specific Ventricle Models with Fluid-Structure Interaction for Cardiac Function Assessment and Surgical Design Optimization

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; del Nido, Pedro J.

    2010-01-01

    Recent advances in medical imaging technology and computational modeling techniques are making it possible that patient-specific computational ventricle models be constructed and used to test surgical hypotheses and replace empirical and often risky clinical experimentation to examine the efficiency and suitability of various reconstructive procedures in diseased hearts. In this paper, we provide a brief review on recent development in ventricle modeling and its potential application in surgical planning and management of tetralogy of Fallot (ToF) patients. Aspects of data acquisition, model selection and construction, tissue material properties, ventricle layer structure and tissue fiber orientations, pressure condition, model validation and virtual surgery procedures (changing patient-specific ventricle data and perform computer simulation) were reviewed. Results from a case study using patient-specific cardiac magnetic resonance (CMR) imaging and right/left ventricle and patch (RV/LV/Patch) combination model with fluid-structure interactions (FSI) were reported. The models were used to evaluate and optimize human pulmonary valve replacement/insertion (PVR) surgical procedure and patch design and test a surgical hypothesis that PVR with small patch and aggressive scar tissue trimming in PVR surgery may lead to improved recovery of RV function and reduced stress/strain conditions in the patch area. PMID:21344066

  10. The bone scan.

    PubMed

    Brenner, Arnold I; Koshy, June; Morey, Jose; Lin, Cheryl; DiPoce, Jason

    2012-01-01

    Bone imaging continues to be the second greatest-volume nuclear imaging procedure, offering the advantage of total body examination, low cost, and high sensitivity. Its power rests in the physiological uptake and pathophysiologic behavior of 99m technetium (99m-Tc) diphosphonates. The diagnostic utility, sensitivity, specificity, and predictive value of 99m-Tc bone imaging for benign conditions and tumors was established when only planar imaging was available. Currently, nearly all bone scans are performed as a planar study (whole-body, 3-phase, or regional), with the radiologist often adding single-photon emission computed tomography (SPECT) imaging. Here we review many current indications for planar bone imaging, highlighting indications in which the planar data are often diagnostically sufficient, although diagnosis may be enhanced by SPECT. (18)F sodium fluoride positron emission tomography (PET) is also re-emerging as a bone agent, and had been considered interchangeable with 99m-Tc diphosphonates in the past. In addition to SPECT, new imaging modalities, including (18)F fluorodeoxyglucose, PET/CT, CT, magnetic resonance, and SPECT/CT, have been developed and can aid in evaluating benign and malignant bone disease. Because (18)F fluorodeoxyglucose is taken up by tumor cells and Tc diphosphonates are taken up in osteoblastic activity or osteoblastic healing reaction, both modalities are complementary. CT and magnetic resonance may supplement, but do not replace, bone imaging, which often detects pathology before anatomic changes are appreciated. We also stress the importance of dose reduction by reducing the dose of 99m-Tc diphosphonates and avoiding unnecessary CT acquisitions. In addition, we describe an approach to image interpretation that emphasizes communication with referring colleagues and correlation with appropriate history to significantly improve our impact on patient care. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery.

    PubMed

    Okamura, Hideo; Padmanabhan, Deepak; Watson, Robert E; Dalzell, Connie; Acker, Nancy; Jondal, Mary; Romme, Abby L; Cha, Yong-Mei; Asirvatham, Samuel J; Felmlee, Joel P; Friedman, Paul A

    2017-05-01

    Magnetic resonance imaging (MRI) in patients with non-MRI-conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported. Prospective data were collected between January 2008 and May 2015 in patients with non-MRI-conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events. MRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power-on-reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005. Patients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing. © 2017 Wiley Periodicals, Inc.

  12. High-pressure autoclave for multipurpose nuclear magnetic resonance measurements up to 10 MPa

    NASA Astrophysics Data System (ADS)

    Behr, W.; Haase, A.; Reichenauer, G.; Fricke, J.

    1999-05-01

    High-pressure nuclear magnetic resonance (NMR) is an established method in NMR spectroscopy: on-line coupling of high-performance liquid chromatography with NMR, for example, reveals structural information which cannot be obtained with any other method. However, applications has been focused solely on high-pressure NMR spectroscopy, even though high-pressure NMR imaging allows in situ studies of processes such as the fluid exchange in porous media. A versatile high-pressure autoclave for NMR imaging is described in this article. The autoclave allows measurements in any horizontal NMR imager using magnetic field coil systems with an inside diameter of more than 70 mm. Any sample with a diameter up to 28 mm and a length of about 200 mm can be investigated. The autoclave is constructed for operating pressures up to 10 MPa and is temperature controlled between 10 and 60 °C. The materials of the high-pressure cell which are the thermoplastic polyetheretherketon (PEEK) for the pressure tube and brass (63% Cu, 37% Zn) for the caps also permit investigations with aggressive fluids such as supercritical carbon dioxide. Inlet and outlet valves allow replacement of fluids and pressure variations in the autoclave during the NMR measurement. FLASH NMR images of the fluid exchange of methanol for liquid carbon dioxide in silica alcogels at 6.5 MPa are presented in order to demonstrate possible applications.

  13. Comparison of radiographic joint space width and magnetic resonance imaging for prediction of knee replacement: A longitudinal case-control study from the Osteoarthritis Initiative.

    PubMed

    Eckstein, Felix; Boudreau, Robert; Wang, Zhijie; Hannon, Michael J; Duryea, Jeff; Wirth, Wolfgang; Cotofana, Sebastian; Guermazi, Ali; Roemer, Frank; Nevitt, Michael; John, Markus R; Ladel, Christoph; Sharma, Leena; Hunter, David J; Kwoh, C Kent

    2016-06-01

    To evaluate whether change in fixed-location measures of radiographic joint space width (JSW) and cartilage thickness by MRI predict knee replacement. Knees replaced between 36 and 60 months' follow-up in the Osteoarthritis Initiative were each matched with one control by age, sex and radiographic status. Radiographic JSW was determined from fixed flexion radiographs and subregional femorotibial cartilage thickness from 3 T MRI. Changes between the annual visit before replacement (T0) and 2 years before T0 (T-2) were compared using conditional logistic regression. One hundred and nineteen knees from 102 participants (55.5 % women; age 64.2 ± 8.7 [mean ± SD] years) were studied. Fixed-location JSW change at 22.5 % from medial to lateral differed more between replaced and control knees (case-control [cc] OR = 1.57; 95 % CI: 1.23-2.01) than minimum medial JSW change (ccOR = 1.38; 95 % CI: 1.11-1.71). Medial femorotibial cartilage loss displayed discrimination similar to minimum JSW, and central tibial cartilage loss similar to fixed-location JSW. Location-independent thinning and thickening scores were elevated prior to knee replacement. Discrimination of structural progression between knee pre-placement cases versus controls was stronger for fixed-location than minimum radiographic JSW. MRI displayed similar discrimination to radiography and suggested greater simultaneous cartilage thickening and loss prior to knee replacement. • Fixed-location JSW predicts surgical knee replacement more strongly than minimum JSW. • MRI predicts knee replacement with similar accuracy to radiographic JSW. • MRI reveals greater cartilage thinning and thickening prior to knee replacement.

  14. Initial experiments with gel-water: towards MRI-linac dosimetry and imaging.

    PubMed

    Alnaghy, Sarah J; Gargett, Maegan; Liney, Gary; Petasecca, Marco; Begg, Jarrad; Espinoza, Anthony; Newall, Matthew K; Duncan, Mitchell; Holloway, Lois; Lerch, Michael L F; Lazea, Mircea; Rosenfeld, Anatoly B; Metcalfe, Peter

    2016-12-01

    Tracking the position of a moving radiation detector in time and space during data acquisition can replicate 4D image-guided radiotherapy (4DIGRT). Magnetic resonance imaging (MRI)-linacs need MRI-visible detectors to achieve this, however, imaging solid phantoms is an issue. Hence, gel-water, a material that provides signal for MRI-visibility, and which will in future work, replace solid water for an MRI-linac 4DIGRT quality assurance tool, is discussed. MR and CT images of gel-water were acquired for visualisation and electron density verification. Characterisation of gel-water at 0 T was compared to Gammex-RMI solid water, using MagicPlate-512 (M512) and RMI Attix chamber; this included percentage depth dose, tissue-phantom ratio (TPR 20/10 ), tissue-maximum ratio (TMR), profiles, output factors, and a gamma analysis to investigate field penumbral differences. MR images of a non-powered detector in gel-water demonstrated detector visualisation. The CT-determined gel-water electron density agreed with the calculated value of 1.01. Gel-water depth dose data demonstrated a maximum deviation of 0.7% from solid water for M512 and 2.4% for the Attix chamber, and by 2.1% for TPR 20/10 and 1.0% for TMR. FWHM and output factor differences between materials were ≤0.3 and ≤1.4%. M512 data passed gamma analysis with 100% within 2%, 2 mm tolerance for multileaf collimator defined fields. Gel-water was shown to be tissue-equivalent for dosimetry and a feasible option to replace solid water.

  15. Clinical features and imaging findings in a case of Capgras syndrome.

    PubMed

    Luca, Maria; Bordone, Andrea; Luca, Antonina; Patti, Andrea; Sortino, Giuseppe; Calandra, Carmela

    2013-01-01

    Capgras syndrome consists of the delusional belief that a person or persons have been replaced by doubles or impostors. It can occur in the context of both psychiatric and organic illness, and seems to be related to lesions of the bifrontal and right limbic and temporal regions. Indeed, magnetic resonance imaging has revealed brain lesions in patients suffering from Capgras syndrome. This case study reports the findings of a thorough diagnostic evaluation in a woman suffering from Capgras syndrome and presenting with the following clinical peculiarities: obsessive modality of presentation of the delusional ideation, intrusiveness of such ideation (that even disturbed her sleep), as well as a sense of alienation and utter disgust towards the double. These characteristics bring to mind the typical aspects of obsessive-compulsive disorder. Neuroanatomic investigation, through magnetic resonance imaging, performed on this patient showed alteration of the bilateral semioval centers, which are brain regions associated with the emotion of disgust and often show alterations in subjects suffering from obsessive-compulsive disorder. Hence, neuroimaging allows researchers to put forward the hypothesis of a common neuroanatomic basis for Capgras syndrome and obsessive-compulsive disorder, at least for cases in which the delusional ideation is associated with deep feelings of disgust and presents with a certain pervasiveness.

  16. Clinical features and imaging findings in a case of Capgras syndrome

    PubMed Central

    Luca, Maria; Bordone, Andrea; Luca, Antonina; Patti, Andrea; Sortino, Giuseppe; Calandra, Carmela

    2013-01-01

    Capgras syndrome consists of the delusional belief that a person or persons have been replaced by doubles or impostors. It can occur in the context of both psychiatric and organic illness, and seems to be related to lesions of the bifrontal and right limbic and temporal regions. Indeed, magnetic resonance imaging has revealed brain lesions in patients suffering from Capgras syndrome. This case study reports the findings of a thorough diagnostic evaluation in a woman suffering from Capgras syndrome and presenting with the following clinical peculiarities: obsessive modality of presentation of the delusional ideation, intrusiveness of such ideation (that even disturbed her sleep), as well as a sense of alienation and utter disgust towards the double. These characteristics bring to mind the typical aspects of obsessive-compulsive disorder. Neuroanatomic investigation, through magnetic resonance imaging, performed on this patient showed alteration of the bilateral semioval centers, which are brain regions associated with the emotion of disgust and often show alterations in subjects suffering from obsessive-compulsive disorder. Hence, neuroimaging allows researchers to put forward the hypothesis of a common neuroanatomic basis for Capgras syndrome and obsessive-compulsive disorder, at least for cases in which the delusional ideation is associated with deep feelings of disgust and presents with a certain pervasiveness. PMID:23950650

  17. Polyglycerolsulfate Functionalized Gold Nanorods as Optoacoustic Signal Nanoamplifiers for In Vivo Bioimaging of Rheumatoid Arthritis

    PubMed Central

    Vonnemann, Jonathan; Beziere, Nicolas; Böttcher, Christoph; Riese, Sebastian B.; Kuehne, Christian; Dernedde, Jens; Licha, Kai; von Schacky, Claudio; Kosanke, Yvonne; Kimm, Melanie; Meier, Reinhard; Ntziachristos, Vasilis; Haag, Rainer

    2014-01-01

    We have synthesized a targeted imaging agent for rheumatoid arthritis based on polysulfated gold nanorods. The CTAB layer on gold nanorods was first replaced with PEG-thiol and then with dendritic polyglycerolsulfate at elevated temperature, which resulted in significantly reduced cytotoxicity compared to polyanionic gold nanorods functionalized by non-covalent approaches. In addition to classical characterization methods, we have established a facile UV-VIS based BaCl2 agglomeration assay to confirm a quantitative removal of unbound ligand. With the help of a competitive surface plasmon resonance-based L-selectin binding assay and a leukocyte adhesion-based flow cell assay, we have demonstrated the high inflammation targeting potential of the synthesized gold nanorods in vitro. In combination with the surface plasmon resonance band of AuNRs at 780 nm, these findings permitted the imaging of inflammation in an in vivo mouse model for rheumatoid arthritis with high contrast using multispectral optoacoustic tomography. The study offers a robust method for otherwise difficult to obtain covalently functionalized polyanionic gold nanorods, which are suitable for biological applications as well as a low-cost, actively targeted, and high contrast imaging agent for the diagnosis of rheumatoid arthritis. This paves the way for further research in other inflammation associated pathologies, in particular, when photothermal therapy can be applied. PMID:24723984

  18. Xanthomatous Hypophysitis Presenting with Diabetes Insipidus Completely Cured Through Transsphenoidal Surgery: Case Report and Literature Review.

    PubMed

    Lin, Wei; Gao, Lu; Guo, Xiaopeng; Wang, Wenze; Xing, Bing

    2017-08-01

    Xanthomatous hypophysitis (XH) is extremely rare. Only 27 cases have been reported in the literature. No XH patient presenting with diabetes insipidus (DI) has been completely cured through surgery. Here, we describe the first XH case of a DI patient whose pituitary function was normalized postoperatively, without hormone replacement therapy. A 41-year-old woman suffered from polydipsia, DI, headache, and breast discharge. Laboratory investigation revealed hyperprolactinemia. Pituitary magnetic resonance imaging showed a 2.0-cm × 1.4-cm × 1.6-cm lesion that demonstrated heterogeneous intensity on T1-weighted imaging and peripheral ring enhancement following contrast; the lesion was totally removed through transsphenoidal surgery. Histopathologic and immunohistochemical examinations confirmed the diagnosis of XH. At the 4- and 15-month follow-up visits, all pituitary-related hormones were normal, and the patient was not taking medication. A repeat pituitary magnetic resonance imaging showed no evidence of recurrence. To the best of our knowledge, this case is the first documented occurrence of XH with DI completely cured through surgery. If XH is suspected, total surgical resection of the lesion is recommended and normal pituitary tissue should be carefully protected intraoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. X-ray cone-beam computed tomography: principles, applications, challenges and solutions

    NASA Astrophysics Data System (ADS)

    Noo, Frederic

    2010-03-01

    In the nineties, x-ray computed tomography, commonly referred to as CT, seemed to be on the track to become old technology, bound to be replaced by more sophisticated techniques such as magnetic resonance imaging, due in particular to the harmful effects of x-ray radiation exposure. Yet, the new century brought with it new technology that allowed a complete change in trends and re-affirmed CT as an essential tool in radiology. For instance, the popularity of CT in 2007 was such that approximately 68.7 million CT examinations were performed in the United States, which was nearly 2.5 times the number of magnetic resonance (MRI) examinations. More than that, CT has expanded beyond its conventional diagnostic role; CT is now used routinely in interventional radiology and also in radiation therapy treatment. The technology advances that allowed the revival of CT are those that made fast, accurate cone-beam data acquisition possible. Nowadays, cone-beam data acquisition allows scanning large volumes with isotropic sub-millimeter spatial resolution in a very fast time, which can be as short as 500ms for cardiac imaging. The principles of cone-beam imaging will be first reviewed. Then a discussion of its applications will be given. Old and new challenges will be presented along the way with current solutions.

  20. Development and validation of a questionnaire evaluating patient anxiety during Magnetic Resonance Imaging: the Magnetic Resonance Imaging-Anxiety Questionnaire (MRI-AQ).

    PubMed

    Ahlander, Britt-Marie; Årestedt, Kristofer; Engvall, Jan; Maret, Eva; Ericsson, Elisabeth

    2016-06-01

    To develop and validate a new instrument measuring patient anxiety during Magnetic Resonance Imaging examinations, Magnetic Resonance Imaging- Anxiety Questionnaire. Questionnaires measuring patients' anxiety during Magnetic Resonance Imaging examinations have been the same as used in a wide range of conditions. To learn about patients' experience during examination and to evaluate interventions, a specific questionnaire measuring patient anxiety during Magnetic Resonance Imaging is needed. Psychometric cross-sectional study with test-retest design. A new questionnaire, Magnetic Resonance Imaging-Anxiety Questionnaire, was designed from patient expressions of anxiety in Magnetic Resonance Imaging-scanners. The sample was recruited between October 2012-October 2014. Factor structure was evaluated with exploratory factor analysis and internal consistency with Cronbach's alpha. Criterion-related validity, known-group validity and test-retest was calculated. Patients referred for Magnetic Resonance Imaging of either the spine or the heart, were invited to participate. The development and validation of Magnetic Resonance Imaging-Anxiety Questionnaire resulted in 15 items consisting of two factors. Cronbach's alpha was found to be high. Magnetic Resonance Imaging-Anxiety Questionnaire correlated higher with instruments measuring anxiety than with depression scales. Known-group validity demonstrated a higher level of anxiety for patients undergoing Magnetic Resonance Imaging scan of the heart than for those examining the spine. Test-retest reliability demonstrated acceptable level for the scale. Magnetic Resonance Imaging-Anxiety Questionnaire bridges a gap among existing questionnaires, making it a simple and useful tool for measuring patient anxiety during Magnetic Resonance Imaging examinations. © 2016 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.

  1. Fluorescent magnetic hybrid nanoprobe for multimodal bioimaging

    PubMed Central

    Bright, Vanessa

    2011-01-01

    A fluorescent magnetic hybrid imaging nanoprobe (HINP) was fabricated by conjugation of superparamagnetic Fe3O4 nanoparticles and visible light-emitting (~600 nm) fluorescent CdTe/CdS quantum dots (QDs). The assembly strategy used the covalent linking of the oxidized dextran shell of magnetic particles to the glutathione ligands of QDs. Synthesized HINP formed stable water-soluble colloidal dispersions. The structure and properties of the particles were characterized by transmission electron and atomic force microscopy, energy dispersive X-ray analysis and inductively coupled plasma optical emission spectroscopy, dynamic light scattering analysis, optical absorption and photoluminescence spectroscopy, and fluorescent imaging. The luminescence imaging region of the nanoprobe was extended to the near-infrared (NIR) (~800 nm) by conjugation of superparamagnetic nanoparticles with synthesized CdHgTe/CdS QDs. Cadmium, mercury based QDs in HINP can be easily replaced by novel water soluble glutathione stabilized AgInS2/ZnS QDs to present a new class of cadmium-free multimodal imaging agents. Observed NIR photoluminescence of fluorescent magnetic nanocomposites supports their use for bioimaging. The developed HINP provides dual-imaging channels for simultaneous optical and magnetic resonance imaging. PMID:21597146

  2. Thoracic Unilateral Spinal Cord Injury After Spinal Anaesthesia for Total Hip Replacement: Fate or Mistake?

    PubMed Central

    Fabio, Costa; Romualdo, Del Buono; Eugenio, Agrò Felice; Vittoradolfo, Tambone; Massimiliano, Vitali Andrea; Giovanna, Ricci

    2017-01-01

    Spinal anaesthesia is the most preffered anesthesia technique for total hip replacement, and its complications range from low entity (insignificant) to life threatening. The incidence of neurologic complications after neuraxial anaesthesia is not perfectly clear, although there are several described cases of spinal cord ischaemia. We present a case of unilateral T8–T11 spinal cord ischaemia following L2–L3 spinal anaesthesia for total hip replacement. Magnetic resonance imaging showed a hyperintense T8–T11 signal alteration on the leftside of paramedian spinal cord. A temporal epidemiologic linkage between the damage and the surgery seems to be present. The injury occurred without anatomical proximity between the injury site and the spinal needle entry site. This may be due to multiple contributing factors, each of them is probably not enough to determine the damage by itself; however, acting simultaneously, they could have been responsible for the complication. The result was unpredictable and unavoidable and was caused by unforeseeable circumstances and not by inadequate medical practice. PMID:28439446

  3. Agenesis of the dorsal pancreas: a rare cause of insulin-dependent diabetes without abdominal pain: Case report.

    PubMed

    Liang, Kaiyong; Ou, Xiaojuan; Huang, Xukai; Lan, Qunfang

    2018-03-01

    Agenesis of the dorsal pancreas is a very rare condition with an unknown pathology and etiology, although it may be associated with autosomal dominant or X-linked dominant inheritance or retinoic acid and hedgehog signaling pathway alterations. This condition usually manifests with abdominal pain or pancreatitis, although some cases are asymptomatic. Approximately 50% of affected patients with this disorder present with hyperglycemia or various other anomalies. We report the case of a 23-year-old Chinese woman who visited the Department of Endocrinology and Metabolism with insulin-dependent diabetes but no specific symptoms, signs, or other deformities. Severe diabetic retinopathy indicated a long period of hyperglycemia. Agenesis of the dorsal pancreas was observed incidentally during the common diagnosis of diabetes, and the diagnosis was established using magnetic resonance imaging, diffusion-weighted imaging, and magnetic resonance cholangiopancreatography. Following the diagnosis of diabetes, insulin replacement therapy was initiated at a dosage of up to 45 U per day. The patient's blood glucose level was monitored, and the insulin dosage was adjusted accordingly. The patient's blood glucose levels gradually normalized after insulin treatment and were subsequently maintained with intensive insulin therapy. Treatment for diabetic retinopathy was provided by the Ophthalmology Department. Agenesis of the dorsal pancreas should be considered in a young patient diagnosed with diabetes who presents with obvious diabetes-related complications (e.g., renal, retinal, or neurological) inconsistent with the course of the disease or a history of other congenital anomalies. We recommend the routine use of computed tomography or magnetic resonance imaging when examining young patients with diabetes.

  4. Primary granulomatous angiitis of the central nervous system: findings of magnetic resonance spectroscopy and fractional anisotropy in diffusion tensor imaging prior to surgery. Case report.

    PubMed

    Beppu, Takaaki; Inoue, Takashi; Nishimoto, Hideaki; Nakamura, Shinichi; Nakazato, Yoichi; Ogasawara, Kuniaki; Ogawa, Akira

    2007-10-01

    Primary granulomatous angiitis of the central nervous system (CNS) is extremely rare. Its preoperative diagnosis is difficult as the condition displays nonspecific features on routine neuroimaging investigations. In this paper, the authors report findings of magnetic resonance (MR) spectroscopy and fractional anisotropy (FA) with diffusion tensor MR imaging in a case of granulomatous angiitis of the CNS. A 30-year-old man presented with morning headaches and grand mal seizures. An MR image revealed a mass resembling glioblastoma in the right temporal lobe. Magnetic resonance spectroscopy showed a high choline/creatine (Cho/Cr) ratio indicative of a malignant neoplasm, accompanied by a slight elevation of glutamate and glutamine. The FA value was very low, which is inconsistent with malignant glioma. The mass was totally removed surgically. Histologically, the peripheral lesion of the mass consisted of a rough accumulation of fat granule cells, infiltration of inflammatory cells, and distribution of capillary vessels. Some vessels within the lesion were replaced by granulomas. The histological diagnosis was granulomatous angiitis of the CNS. The MIB-1-positive rate of the granuloma was approximately 5%. Both MR spectroscopy and FA were unable to accurately diagnose granulomatous angiitis of the CNS prior to surgery; however, elevated Cho/Cr and glutamate and glutamine shown by MR spectroscopy may indicate the moderate proliferation potential of the granuloma and the inflammatory process, respectively, in this condition. Although the low FA value in the present case enabled the authors to rule out a diagnosis of glioblastoma, FA values in inflammatory lesions require careful interpretation.

  5. [A case of curable encephalomyelitis in a tropical area: pernicious anemia].

    PubMed

    Razafimahefa, S H; Razafimahefa, J; Rabenjanahary, T H; Rakotoarivelo, R A; Andriantseheno, M; Ramanampamonjy, R M; Rajaona, H R

    2011-06-01

    Pernicious anemia is uncommon in Africa. The purpose of this report is to describe a case of pernicious anemia observed in Madagascar. The revealing manifestation was encephalomyelitis with combined medullar sclerosis that responded favorably to vitamin B12 replacement therapy. Clinical symptoms included paresthesia associated with allodynia of all four extremities and with tetrapyramidal syndrome, medullar ataxia and minor cognitive disturbances ongoing for 5 months. Hemogram testing revealed macrocytic anemia. Serum cobalamin level was low. Anti-intrinsic factor antibody was detected. Spinal cord magnetic resonance imaging showed diffuse high-signal intensity along the posterior spinal cord extending from C1 to C4. Vitamin B12 replacement therapy led to full regression of clinical signs after six weeks. Association of central nervous system involvement with macrocytic anemia suggests vitamin B12 deficiency and pernicious anemia should be suspected. This disease can be considered as a curable form of myelitis in Africa and Madagascar.

  6. Gargantuan left atrium: a sequela of mitral regurgitation and mitral stenosis.

    PubMed

    Omslaer, Brian T; Biederman, Robert W W

    2015-06-01

    Cardiac magnetic resonance imaging and echocardiography revealed a gargantuan left atrium measuring 18.9 cm × 15.7 cm × 11.3 cm in a 56-year-old patient diagnosed with severe rheumatic mitral stenosis, severe pulmonary hypertension, and permanent atrial fibrillation. A chest x-ray also revealed a cardiothoracic ratio approaching 1.0 and a transthoracic echocardiogram measured diameters as large as 19.2 cm. The patient then underwent mitral valve replacement and left atrial reduction surgery and has had no further admissions or complications. © 2015, Wiley Periodicals, Inc.

  7. Pituitary adenoma associated with gigantism and hyperprolactinemia.

    PubMed

    Alikasifoglu, A; Kandemir, N; Akalan, N; Yordam, N

    2001-12-01

    An 11-year-old girl presented with excessive growth, headache, left visual loss and seizures. Her growth hormone (GH) and prolactin (PRL) levels were high and magnetic resonance imaging findings showed an invasive macroadenoma. Gross total tumor removal was performed and then radiotherapy and medical therapy were given. During the follow-up, she developed ACTH deficiency, secondary hypothyroidism and hypogonadism requiring replacement therapy. It is still unclear whether the biological characteristics of GH- and PRL-secreting tumors are different in children from those in adults. More data are needed before a definitive conclusion can be established. Copyright 2001 S. Karger AG, Basel

  8. Synthesis and in vitro evaluation of bone-seeking superparamagnetic iron oxide nanoparticles as contrast agents for imaging bone metabolic activity.

    PubMed

    Panahifar, Arash; Mahmoudi, Morteza; Doschak, Michael R

    2013-06-12

    In this article, we report the synthesis and in vitro evaluation of a new class of nonionizing bone-targeting contrast agents based on bisphosphonate-conjugated superparamagnetic iron oxide nanoparticles (SPIONs), for use in imaging of bone turnover with magnetic resonance imaging (MRI). Similar to bone-targeting (99m)Technetium medronate, our novel contrast agent uses bisphosphonates to impart bone-seeking properties, but replaces the former radioisotope with nonionizing SPIONs which enables their subsequent detection using MRI. Our reported method is relatively simple, quick and cost-effective and results in BP-SPIONs with a final nanoparticle size of 17 nm under electron microscopy technique (i.e., TEM). In-vitro binding studies of our novel bone tracer have shown selective binding affinity (around 65%) for hydroxyapatite, the principal mineral of bone. Bone-targeting SPIONs offer the potential for use as nonionizing MRI contrast agents capable of imaging dynamic bone turnover, for use in the diagnosis and monitoring of metabolic bone diseases and related bone pathology.

  9. [Magnetic resonance enterography: technique and indications. Findings in Crohn's disease].

    PubMed

    Torregrosa, A; Pallardó, Y; Hinojosa, J; Insa, S; Molina, R

    2013-09-01

    Radiology with oral contrast, or enteroclysis, have traditionally been the techniques of choice in the examination of the small intestine, due to the excellent visualisation of the mucosal pattern. However, the absence of extra-luminal information and the use of ionising radiation have replaced these examinations with sectional techniques which enable the abdominal cavity to be viewed with good resolution. Magnetic resonance enterography is a simple technique, with no ionising radiation, provided quality images, distends the intestinal lumen well by the administration of non-reabsorbable oral substances, minimises peristalsis, and establishes a protocol which includes sequences with intravenous contrast. These properties can be used in patients with Crohn's disease, achieving good diagnostic precision in the assessment of activity and monitoring of treatment, in intestinal obstruction, in the suspicion of small intestine tumours, and in paediatric patients due to it being harmless. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  10. Implantation of the Medtronic Harmony Transcatheter Pulmonary Valve Improves Right Ventricular Size and Function in an Ovine Model of Postoperative Chronic Pulmonary Insufficiency.

    PubMed

    Schoonbeek, Rosanne C; Takebayashi, Satoshi; Aoki, Chikashi; Shimaoka, Toru; Harris, Matthew A; Fu, Gregory L; Kim, Timothy S; Dori, Yoav; McGarvey, Jeremy; Litt, Harold; Bouma, Wobbe; Zsido, Gerald; Glatz, Andrew C; Rome, Jonathan J; Gorman, Robert C; Gorman, Joseph H; Gillespie, Matthew J

    2016-10-01

    Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary insufficiency. Thirteen sheep underwent baseline cardiac magnetic resonance imaging, surgical pulmonary valvectomy, and transannular patch repair. One month after transannular patch repair, the hTPV was implanted, followed by serial magnetic resonance imaging and computed tomography imaging at 1, 5, and 8 month(s). hTPV implantation was successful in 11 animals (85%). There were 2 procedural deaths related to ventricular fibrillation. Seven animals survived the entire follow-up protocol, 5 with functioning hTPV devices. Two animals had occlusion of hTPV with aneurysm of main pulmonary artery. A strong decline in pulmonary regurgitant fraction was observed after hTPV implantation (40.5% versus 8.3%; P=0.011). Right ventricular end diastolic volume increased by 49.4% after transannular patch repair (62.3-93.1 mL/m 2 ; P=0.028) but was reversed to baseline values after hTPV implantation (to 65.1 mL/m 2 at 8 months, P=0.045). Both right ventricular ejection fraction and left ventricular ejection fraction were preserved after hTPV implantation. hTPV implantation is feasible, significantly reduces pulmonary regurgitant fraction, facilitates right ventricular volume improvements, and preserves biventricular function in an ovine model of chronic pulmonary insufficiency. This percutaneous strategy could potentially offer an alternative for standard surgical pulmonary valve replacement in dilated right ventricular outflow tracts, permitting lower risk, nonsurgical pulmonary valve replacement in previously prohibitive anatomies. © 2016 American Heart Association, Inc.

  11. [Testosterone replacement therapy for late-onset hypogonadism after radical prostatectomy: a case report].

    PubMed

    Nakano, Kosuke; Kiuchi, Hiroshi; Miyagawa, Yasushi; Tsujimura, Akira; Nonomura, Norio

    2014-08-01

    A 53-year-old man presented to our hospital with a few-month history of fatigue and anorexia. His aging male's symptoms (AMS) score was 57, and the free testosterone value was low (6.5 pg/ml). He was diagnosed with severe late-onset hypogonadism indicative of androgen replacement therapy (ART). His serum prostate specific antigen was 8.7 ng/ml, and pelvic magnetic resonance imaging showed a low intensity area in the peripheral zone of the prostate. A systematic 10-core prostate biopsy revealed one core of adenocarcinoma with a Gleason score of 3 + 3=6. Imaging examination revealed organ-confined prostate cancer that was cT2aN0M0. Given his desire for ART for the treatment of hypogonadism, the patient underwent open radical prostatectomy. Pathologic examination demonstrated prostate adenocarcinoma that was pT2aN0, and Gleason score of 3 + 3=6. After confirming that the prostate specific antigen value was under 0.01 ng/ml for three years after prostatectomy, the patient received 125 mg methyltestosterone monthly. His hypogonadism-related symptoms diminished and AMS score dropped to 48. During a three-year follow-up of ART, no biochemical recurrence was found.

  12. Patient selection for transcatheter aortic valve replacement: A combined clinical and multimodality imaging approach

    PubMed Central

    Cocchia, Rosangela; D’Andrea, Antonello; Conte, Marianna; Cavallaro, Massimo; Riegler, Lucia; Citro, Rodolfo; Sirignano, Cesare; Imbriaco, Massimo; Cappelli, Maurizio; Gregorio, Giovanni; Calabrò, Raffaele; Bossone, Eduardo

    2017-01-01

    Transcatheter aortic valve replacement (TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindication or high operative risk. Patient selection for TAVR should be based not only on accurate assessment of aortic stenosis morphology, but also on several clinical and functional data. Multi-Imaging modalities should be preferred for assessing the anatomy and the dimensions of the aortic valve and annulus before TAVR. Ultrasounds represent the first line tool in evaluation of this patients giving detailed anatomic description of aortic valve complex and allowing estimating with enough reliability the hemodynamic entity of valvular stenosis. Angiography should be used to assess coronary involvement and plan a revascularization strategy before the implant. Multislice computed tomography play a central role as it can give anatomical details in order to choice the best fitting prosthesis, evaluate the morphology of the access path and detect other relevant comorbidities. Cardiovascular magnetic resonance and positron emission tomography are emergent modality helpful in aortic stenosis evaluation. The aim of this review is to give an overview on TAVR clinical and technical aspects essential for adequate selection. PMID:28400918

  13. Magnetic Resonance Imaging

    MedlinePlus

    ... specific information about your own examination. What is magnetic resonance imaging (MRI)? What is MRI used for? How safe ... What is the MRI examination like? What is magnetic resonance imaging (MRI)? MRI, or magnetic resonance imaging, is a ...

  14. Performance of magnetic resonance imaging in the evaluation of first-time and reoperative primary hyperparathyroidism.

    PubMed

    Kluijfhout, Wouter P; Venkatesh, Shriya; Beninato, Toni; Vriens, Menno R; Duh, Quan-Yang; Wilson, David M; Hope, Thomas A; Suh, Insoo

    2016-09-01

    Preoperative imaging in patients with primary hyperparathyroidism and a previous parathyroid operation is essential; however, performance of conventional imaging is poor in this subgroup. Magnetic resonance imaging appears to be a good alternative, though overall evidence remains scarce. We retrospectively investigated the performance of magnetic resonance imaging in patients with and without a previous parathyroid operation, with a separate comparison for dynamic gadolinium-enhanced magnetic resonance imaging. All patients undergoing magnetic resonance imaging prior to parathyroidectomy for primary hyperparathyroidism (first time or recurrent) between January 2000 and August 2015 at a high-volume, tertiary care, referral center for endocrine operations were included. We compared the sensitivity and positive predictive value of magnetic resonance imaging with conventional ultrasound and sestamibi on a per-lesion level. A total of 3,450 patients underwent parathyroidectomy, of which 84 patients with recurrent (n = 10) or persistent (n = 74) disease and 41 patients with a primary operation were included. Magnetic resonance imaging had a sensitivity and positive predictive value of 79.9% and 84.7%, respectively, and performance was good in both patients with and without a previous parathyroid operation. Adding magnetic resonance imaging to the combination of ultrasound and sestamibi resulted in a significant increase in sensitivity from 75.2% to 91.5%. Dynamic magnetic resonance imaging produced excellent results in the reoperative group, with sensitivity and a positive predictive value of 90.1%. Technologic advances have enabled faster and more accurate magnetic resonance imaging protocols, making magnetic resonance imaging an excellent alternative modality without associated ionizing radiation. Our study shows that the sensitivity of multimodality imaging for parathyroid adenomas improved significantly with the use of conventional and dynamic magnetic resonance imaging, even in the case of recurrent or persistent disease. Published by Elsevier Inc.

  15. Effects of enzyme-replacement therapy in patients with Anderson-Fabry disease: a prospective long-term cardiac magnetic resonance imaging study.

    PubMed

    Imbriaco, M; Pisani, A; Spinelli, L; Cuocolo, A; Messalli, G; Capuano, E; Marmo, M; Liuzzi, R; Visciano, B; Cianciaruso, B; Salvatore, M

    2009-07-01

    Anderson-Fabry disease is a multisystem X linked disorder of lipid metabolism frequently associated with cardiac symptoms, including left ventricular (LV) hypertrophy gradually impairing cardiac function. Evidence showing that enzyme-replacement therapy (ERT) can be effective in reducing LV hypertrophy and improving myocardial function in the long term is limited. This study aimed to assess the long-term effects of ERT with recombinant alpha-galactosidase A (agalsidase beta, Fabrazyme) on LV function and myocardial signal intensity in 11 patients with Anderson-Fabry disease. Eleven patients (eight males, three females) with varying stages of genetically confirmed Anderson-Fabry disease were examined by means of physical examination and magnetic resonance imaging before ERT with agalsidase beta at 1 mg/kg every other week (study 1) and after a mean treatment duration of 45 months (study 2). At 45 months of treatment, LV mass and LV wall thickness had significantly reduced: 188 (SD 60) g versus 153 (47) g, and 16 (4) mm versus 14 (4) mm, respectively. Furthermore, a significant reduction in myocardial T2 relaxation times was noted in all myocardial regions, that is, interventricular septum 80 (5) ms versus 66 (8) ms, apex 79 (10) ms versus 64 (10) ms, and lateral wall 80 (8) ms versus 65 (16) ms. Changes in LV ejection fraction were not significant. Amelioration of clinical symptoms was observed in all patients. Long-term therapy with agalsidase beta at 1 mg/kg every 2 weeks was effective in significantly reducing LV hypertrophy, improving overall cardiac performance and ameliorating clinical symptoms in patients with Anderson-Fabry disease.

  16. Magnetic Resonance Imaging (MRI): Dynamic Pelvic Floor

    MedlinePlus

    ... Site Index A-Z Magnetic Resonance Imaging (MRI) – Dynamic Pelvic Floor Dynamic pelvic floor magnetic resonance imaging ( ... the limitations of pelvic floor MRI? What is dynamic pelvic floor MRI? Magnetic resonance imaging (MRI) is ...

  17. Diffusion-Weighted Magnetic Resonance Imaging of Cholesteatoma Using PROPELLER at 1.5T: A Single-Centre Retrospective Study.

    PubMed

    Clarke, Sharon E; Mistry, Dipan; AlThubaiti, Talal; Khan, M Naeem; Morris, David; Bance, Manohar

    2017-05-01

    The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  18. How to Build a Hybrid Neurofeedback Platform Combining EEG and fMRI

    PubMed Central

    Mano, Marsel; Lécuyer, Anatole; Bannier, Elise; Perronnet, Lorraine; Noorzadeh, Saman; Barillot, Christian

    2017-01-01

    Multimodal neurofeedback estimates brain activity using information acquired with more than one neurosignal measurement technology. In this paper we describe how to set up and use a hybrid platform based on simultaneous electroencephalography (EEG) and functional magnetic resonance imaging (fMRI), then we illustrate how to use it for conducting bimodal neurofeedback experiments. The paper is intended for those willing to build a multimodal neurofeedback system, to guide them through the different steps of the design, setup, and experimental applications, and help them choose a suitable hardware and software configuration. Furthermore, it reports practical information from bimodal neurofeedback experiments conducted in our lab. The platform presented here has a modular parallel processing architecture that promotes real-time signal processing performance and simple future addition and/or replacement of processing modules. Various unimodal and bimodal neurofeedback experiments conducted in our lab showed high performance and accuracy. Currently, the platform is able to provide neurofeedback based on electroencephalography and functional magnetic resonance imaging, but the architecture and the working principles described here are valid for any other combination of two or more real-time brain activity measurement technologies. PMID:28377691

  19. Acute Brain Imaging in Children: Can MRI Replace CT as a Screening Tool?

    PubMed

    Wagner, Matthias W; Kontzialis, Marinos; Seeburg, Daniel; Stern, Steven E; Oshmyansky, Alexander; Poretti, Andrea; Huisman, Thierry A G M

    2016-01-01

    To determine if axial T2-weighted imaging can serve as screening tool for pediatric brain imaging. We retrospectively evaluated consecutive brain magnetic resonance imaging (MRI) data of 161 children (74 girls) with a mean age of 7.44 ± 5.71 years. Standard of reference was the final report of neuroradiology attendings. Three readers with different levels of experience were blinded for clinical diagnoses and study indications. First, readers studied only the axial T2-weighted screening sequence. Second, they studied all available anatomical and functional MRI sequences as performed per standard protocol for each clinical indication. The readings were classified as normal or abnormal. Sensitivity and specificity were measured. Axial T2 screening yielded a sensitivity of 77-88% and a specificity of 92%. The full studies/data sets had a sensitivity of 89-95% and a specificity of 86-93%. Nineteen of 167 studies were acquired for acute and 148 of 167 studies for nonacute clinical indication. Twenty-five false-negative diagnoses paneled in three groups were made by all readers together. Readers misread four of 19 studies with acute and 21 of 148 studies with nonacute clinical indication. Four of 21 misread studies with nonacute indications harbored unexpected findings needing management. Axial T2 screening can detect pediatric brain abnormalities with high sensitivity and specificity and can possibly replace CT as screening tool if the reading physician is aware of possible limitations/pitfalls. The level of experience influences sensitivity and specificity. Adding diffusion-weighted imaging and susceptibility-weighted imaging to a 3-dimensional T2-weighted sequence would most likely further increase sensitivity and specificity. Copyright © 2015 by the American Society of Neuroimaging.

  20. Muscle ultrasound elastography and MRI in preschool children with Duchenne muscular dystrophy.

    PubMed

    Pichiecchio, Anna; Alessandrino, Francesco; Bortolotto, Chandra; Cerica, Alessandra; Rosti, Cristina; Raciti, Maria Vittoria; Rossi, Marta; Berardinelli, Angela; Baranello, Giovanni; Bastianello, Stefano; Calliada, Fabrizio

    2018-06-01

    The aim of this study was to determine muscle tissue elasticity, measured with shear-wave elastography, in selected lower limb muscles of patients affected by Duchenne muscular dystrophy (DMD) and to correlate the values obtained with those recorded in healthy children and with muscle magnetic resonance imaging (MRI) data from the same DMD children, specifically the pattern on T1-weighted (w) and short-tau inversion recovery (STIR) sequences. Five preschool DMD children and five age-matched healthy children were studied with shear-wave elastography. In the DMD children, muscle stiffness was moderately higher compared with the muscle stiffness in HC, in the rectus femoris, vastus lateralis, adductor magnus and gluteus maximus muscles. On muscle MRI T1-w images showed fatty replacement in 3/5 patients at the level of the GM, while thigh and leg muscles were affected in 2/5; hyperintensity on STIR images was identified in 4/5 patients. No significant correlation was observed between stiffness values and MRI scoring. Our study demonstrated that lower limb muscles of preschool DMD patients show fatty replacement and patchy edema on muscle MRI and increased stiffness on shear-wave elastography. In conclusion, although further studies in larger cohorts are needed, shear-wave elastography could be considered a useful non-invasive tool to easily monitor muscle changes in early stages of the disease. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. [MR tomography of the heart].

    PubMed

    Hahn, D; Beer, M; Sandstede, J

    2000-10-01

    The introduction of magnetic resonance (MR) tomography has fundamentally changed radiological diagnosis for many diseases. Invasive digital subtraction angiography has already been widely replaced by noninvasive MR angiography for most of the vascular diseases. The rapid technical development of MR imaging in recent years has opened new functional imaging techniques. MR imaging of the heart allows simultaneous measurement of morphological and functional parameters in a single noninvasive examination without any radiation exposure. Because of the high spatial resolution and the reproducibility cine MR imaging is now the gold standard for functional analysis. With the improvement of myocardial perfusion and viability studies many diseases of the heart can be diagnosed in a single examination. MR spectroscopy is the only method which allows a view of the metabolism of the heart. New examinations for vascular imaging and flow quantification complete the goal of "one-stop-shop" imaging of the heart. MR imaging is the only diagnostic modality which allows a complete evaluation of many diseases of the heart with one technique, basic examination as well as follow-up studies. The very rapid improvement in MRI will overcome most of the limitations in the near future, especially concerning MR coronary angiography.

  2. Sinonasal papilloma: what influences the decision to request a magnetic resonance imaging scan?

    PubMed

    Kasbekar, A V; Swords, C; Attlmayr, B; Kulkarni, T; Swift, A C

    2018-06-18

    Computed tomography is the standard pre-operative imaging modality for sinonasal papilloma. The complementary use of magnetic resonance imaging as an additional investigation is debated. This study aimed to establish whether magnetic resonance imaging can accurately detect tumour extent and is a useful adjunct to computed tomography. A retrospective review was conducted on 19 patients with sinonasal papilloma. The interpretation of computed tomography and magnetic resonance imaging scans, by three clinicians, was conducted by comparing prediction of tumour extent. The perceived necessity of magnetic resonance imaging was compared between clinicians. The addition of magnetic resonance imaging improved accuracy of pre-operative interpretation; specifically, this finding was significant in cases with frontal sinus involvement. Surgeons were more likely than a radiologist to request magnetic resonance imaging, particularly when computed tomography indicated frontal sinus disease. Pre-operative combined magnetic resonance imaging and computed tomography helped predict disease in the frontal sinus better than computed tomography alone. A close working relationship between the ENT and radiology departments is important for accurate tumour localisation.

  3. Preoperative Magnetic Resonance Imaging in Patients With Stage I Invasive Ductal Breast Cancer: A Prospective Randomized Study.

    PubMed

    Brück, N; Koskivuo, I; Boström, P; Saunavaara, J; Aaltonen, R; Parkkola, R

    2018-03-01

    Preoperative magnetic resonance imaging has become an important complementary imaging technique in patients with breast cancer, providing additional information for preoperative local staging. Magnetic resonance imaging is recommended selectively in lobular breast cancer and in patients with dense breast tissue in the case when mammography and ultrasound fail to fully evaluate the lesion, but the routine use of magnetic resonance imaging in all patients with invasive ductal carcinoma is controversial. The purpose of this randomized study was to investigate the diagnostic value of preoperative magnetic resonance imaging and its impact on short-term surgical outcome in newly diagnosed unifocal stage I invasive ductal carcinoma. A total of 100 patients were randomized to either receive preoperative breast magnetic resonance imaging or to be scheduled directly to operation without magnetic resonance imaging on a 1:1 basis. There were 50 patients in both study arms. In 14 patients (28%), breast magnetic resonance imaging detected an additional finding and seven of them were found to be malignant. Six additional cancer foci were found in the ipsilateral breast and one in the contralateral breast. Magnetic resonance imaging findings caused a change in planned surgical management in 10 patients (20%). Mastectomy was performed in six patients (12%) in the magnetic resonance imaging group and in two patients (4%) in the control group ( p = 0.140). The breast reoperation rate was 14% in the magnetic resonance imaging group and 24% in the control group ( p = 0.202). The mean interval between referral and first surgical procedure was 34 days in the magnetic resonance imaging group and 21 days in the control group ( p < 0.001). Preoperative magnetic resonance imaging may be beneficial for some patients with early-stage invasive ductal carcinoma, but its routine use is not recommended without specific indications.

  4. Surface plasmon resonance application for herbicide detection

    NASA Astrophysics Data System (ADS)

    Chegel, Vladimir I.; Shirshov, Yuri M.; Piletskaya, Elena V.; Piletsky, Sergey A.

    1998-01-01

    The optoelectronic biosensor, based on Surface Plasmon Resonance (SPR) for detection of photosynthesis-inhibiting herbicides in aqueous solutions is presented. The pesticide capability to replace plastoquinone from its complex with D1 protein is used for the detection. This replacement reaction results in the changes of the optical characteristics of protein layer, immobilized on the gold surface. Monitoring of these changes with SPR-technique permit to determine 0.1 - 5.0 mkg/ml herbicide in solution within one hour.

  5. Surface plasmon resonance application for herbicide detection

    NASA Astrophysics Data System (ADS)

    Chegel, Vladimir I.; Shirshov, Yuri M.; Piletskaya, Elena V.; Piletsky, Sergey A.

    1997-12-01

    The optoelectronic biosensor, based on Surface Plasmon Resonance (SPR) for detection of photosynthesis-inhibiting herbicides in aqueous solutions is presented. The pesticide capability to replace plastoquinone from its complex with D1 protein is used for the detection. This replacement reaction results in the changes of the optical characteristics of protein layer, immobilized on the gold surface. Monitoring of these changes with SPR-technique permit to determine 0.1 - 5.0 mkg/ml herbicide in solution within one hour.

  6. Role of Magnetic Resonance Imaging Targeted Biopsy in Detection of Prostate Cancer Harboring Adverse Pathological Features of Intraductal Carcinoma and Invasive Cribriform Carcinoma.

    PubMed

    Prendeville, Susan; Gertner, Mark; Maganti, Manjula; Pintilie, Melania; Perlis, Nathan; Toi, Ants; Evans, Andrew J; Finelli, Antonio; van der Kwast, Theodorus H; Ghai, Sangeet

    2018-07-01

    The aim of this study was to compare biopsy detection of intraductal and cribriform pattern invasive prostate carcinoma in multiparametric magnetic resonance imaging positive and negative regions of the prostate. We queried a prospectively maintained, single institution database to identify patients who underwent multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy and concurrent systematic sextant biopsy of magnetic resonance imaging negative regions between January 2013 and May 2016. All multiparametric magnetic resonance imaging targets were reviewed retrospectively by 2 readers for the PI-RADS™ (Prostate Imaging-Reporting and Data System), version 2 score, the maximum dimension, the apparent diffusion coefficient parameter and whether positive or negative on dynamic contrast enhancement sequence. Biopsy slides were reviewed by 2 urological pathologists for Gleason score/Grade Group and the presence or absence of an intraductal/cribriform pattern. A total of 154 patients were included in study. Multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy and systematic sextant biopsy of magnetic resonance imaging negative regions were negative for prostate carcinoma in 51 patients, leaving 103 available for the correlation of multiparametric magnetic resonance imaging and the intraductal/cribriform pattern. Prostate carcinoma was identified by multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy in 93 cases and by systematic sextant biopsy of magnetic resonance imaging negative regions in 76 (p = 0.008). Intraductal/cribriform positive tumor was detected in 23 cases, including at the multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy site in 22 and at the systematic sextant biopsy of magnetic resonance imaging negative region site in 3 (p <0.001). The intraductal/cribriform pattern was significantly associated with a PI-RADS score of 5 and a decreasing apparent diffusion coefficient value (p = 0.008 and 0.005, respectively). In 19 of the 23 cases with the intraductal/cribriform pattern prior 12-core standard systematic biopsy was negative in 8 and showed Grade Group 1 disease in 11. Multiparametric magnetic resonance imaging/ultrasound fusion targeted biopsy was associated with significantly increased detection of intraductal/cribriform positive prostate carcinoma compared to systematic sextant biopsy of multiparametric magnetic resonance imaging negative regions. This supports the role of magnetic resonance imaging to enhance the detection of clinically aggressive intraductal/cribriform positive prostate carcinoma. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Morphological MRI characteristics of recent small subcortical infarcts.

    PubMed

    Gattringer, Thomas; Eppinger, Sebastian; Pinter, Daniela; Pirpamer, Lukas; Berghold, Andrea; Wünsch, Gerit; Ropele, Stefan; Wardlaw, Joanna M; Enzinger, Christian; Fazekas, Franz

    2015-10-01

    New imaging criteria for recent small subcortical infarcts have recently been proposed, replacing the earlier term 'lacunar infarction', but their applicability and impact on lesion selection is yet unknown. To collect information on the morphologic characteristics and variability of recent small subcortical infarcts on magnetic resonance imaging in regard to lesion location and demographic variables. We identified all patients with acute stroke and cerebral magnetic resonance imaging from 2008 to 2013 in our hospital database and selected those with a single recent small subcortical infarct defined by an estimated maximal axial diameter of 20 mm. Recent small subcortical infarcts were segmented on diffusion-weighted imaging and fluid-attenuated inversion recovery sequence to calculate the largest axial and longitudinal diameter and lesion volume. We assessed morphometric differences of recent small subcortical infarcts regarding location and demographic variables and the impact of different recent small subcortical infarct definitions on lesion selection. Three hundred forty-four patients (median age 72; range 25-92 years, 65% male) were selected. Most recent small subcortical infarcts were located in the basal ganglia (n = 111), followed by pons (n = 92), thalamus (n = 77), and centrum semiovale (n = 64). Quantitative measurements confirmed visual assessment of the axial diameter in 95%. All morphometric variables were strongly intercorrelated and comparable on diffusion-weighted imaging and fluid-attenuated inversion recovery sequence. Recent small subcortical infarcts in the basal ganglia were significantly larger both in the axial and longitudinal direction compared with other regions. Dichotomization of recent small subcortical infarcts according to axial (≤ / >15 mm) or longitudinal (≤ / >20 mm) sizes resulted in different regional frequencies and distributions. Age, gender, and time from stroke onset to magnetic resonance imaging did not influence lesion metrics or the distribution of recent small subcortical infarcts. Our study confirms the recent neuroimaging criteria for recent small subcortical infarcts as a practical concept. Definitions of the maximal axial and longitudinal diameter have a significant impact on the frequency and distribution of selected infarcts, which has to be considered for future studies. © 2015 World Stroke Organization.

  8. Reforming the taxonomy in disorders of consciousness.

    PubMed

    Bayne, Tim; Hohwy, Jakob; Owen, Adrian M

    2017-12-01

    This article examines the serious shortcomings that characterize the current taxonomy of postcomatose disorders of consciousness (DoC), and it provides guidelines for how an improved DoC taxonomy might be developed. In particular, it is argued that behavioral criteria for the application of DoC categories should be supplemented with brain-based criteria (eg, information derived from electroencephalography and functional magnetic resonance imaging), and that the categorical framework that currently characterizes DoC should be replaced by a multidimensional framework that better captures the performance of patients across a range of cognitive and behavioural tasks. Ann Neurol 2017;82:866-872. © 2017 American Neurological Association.

  9. Can glenoid wear be accurately assessed using x-ray imaging? Evaluating agreement of x-ray and magnetic resonance imaging (MRI) Walch classification.

    PubMed

    Kopka, Michaela; Fourman, Mitchell; Soni, Ashish; Cordle, Andrew C; Lin, Albert

    2017-09-01

    The Walch classification is the most recognized means of assessing glenoid wear in preoperative planning for shoulder arthroplasty. This classification relies on advanced imaging, which is more expensive and less practical than plain radiographs. The purpose of this study was to determine whether the Walch classification could be accurately applied to x-ray images compared with magnetic resonance imaging (MRI) as the gold standard. We hypothesized that x-ray images cannot adequately replace advanced imaging in the evaluation of glenoid wear. Preoperative axillary x-ray images and MRI scans of 50 patients assessed for shoulder arthroplasty were independently reviewed by 5 raters. Glenoid wear was individually classified according to the Walch classification using each imaging modality. The raters then collectively reviewed the MRI scans and assigned a consensus classification to serve as the gold standard. The κ coefficient was used to determine interobserver agreement for x-ray images and independent MRI reads, as well as the agreement between x-ray images and consensus MRI. The inter-rater agreement for x-ray images and MRIs was "moderate" (κ = 0.42 and κ = 0.47, respectively) for the 5-category Walch classification (A1, A2, B1, B2, C) and "moderate" (κ = 0.54 and κ = 0.59, respectively) for the 3-category Walch classification (A, B, C). The agreement between x-ray images and consensus MRI was much lower: "fair-to-moderate" (κ = 0.21-0.51) for the 5-category and "moderate" (κ = 0.36-0.60) for the 3-category Walch classification. The inter-rater agreement between x-ray images and consensus MRI is "fair-to-moderate." This is lower than the previously reported reliability of the Walch classification using computed tomography scans. Accordingly, x-ray images are inferior to advanced imaging when assessing glenoid wear. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Three-Dimensional Isotropic Fat-Suppressed Proton Density-Weighted MRI at 3 Tesla Using a T/R-Coil Can Replace Multiple Plane Two-Dimensional Sequences in Knee Imaging.

    PubMed

    Homsi, R; Gieseke, J; Luetkens, J A; Kupczyk, P; Maedler, B; Kukuk, G M; Träber, F; Agha, B; Rauch, M; Rajakaruna, N; Willinek, W; Schild, H H; Hadizadeh, D R

    2016-10-01

    To evaluate whether a 3 D proton density-weighted fat-suppressed sequence (PDwFS) of the knee is able to replace multiplanar 2D-PDwFS. 52 patients (26 men, mean age: 41.9 ± 14.5years) underwent magnetic resonance imaging (MRI) of the knee at 3.0 Tesla using a T/R-coil. The imaging protocol included 3 planes of 2D-PDwFS (acquisition time (AT): 6:40 min; voxel sizes: 0.40 - 0.63 × 0.44 - 0.89 × 3mm³) and a 3D-PDwFS (AT: 6:31 min; voxel size: 0.63 × 0.68 × 0.63mm³). Homogeneity of fat suppression (HFS), artifacts, and image sharpness (IS) were evaluated on a 5-point scale (5[excellent] - 1[non-diagnostic]). The sum served as a measure for the overall image quality (OIQ). Contrast ratios (CR) compared to popliteal muscle were calculated for the meniscus (MEN), anterior (ACL) and posterior cruciate ligaments (PCL). In 13 patients who underwent arthroscopic knee surgery, two radiologists evaluated the presence of meniscal, ligamental and cartilage lesions to estimate the sensitivity and specificity of lesion detection. The CR was higher in the ACL, PCL and MEN in 3D- PDwFS compared to 2D-PDwFS (p < 0.01 for ACL and PCL; p = 0.07 for MEN). Compared to 2 D images, the OIQ was rated higher in 3D-PDwFS images (p < 0.01) due to fewer artifacts and HFS despite the lower IS (p < 0.01). The sensitivity and specificity of lesion detection in 3D- and 2D-PDwFS were similar. Compared to standard multiplanar 2D-PDwFS knee imaging, isotropic high spatial resolution 3D-PDwFS of the knee at 3.0 T can be acquired with high image quality in a reasonable scan time. Multiplanar reformations in arbitrary planes may serve as an additional benefit of 3D-PDwFS. • 3D-PDwFS of the knee is acquired with high image quality• 3D-PDwFS can be achieved in only one measurement with a reasonable scan time• 3D-PDwFS with the advantage of multiplanar reformation may replace 2D-PD-weighted knee MRI Citation Format: • Homsi R, Gieseke J, Luetkens JA et al. Three-Dimensional Isotropic Fat-Suppressed Proton Density-Weighted MRI at 3 Tesla Using a T/R-Coil Can Replace Multiple Plane Two-Dimensional Sequences in Knee Imaging. Fortschr Röntgenstr 2016; 188: 949 - 956. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Magnetic resonance conditional paramagnetic choke for suppression of imaging artifacts during magnetic resonance imaging.

    PubMed

    Wu, Kevin J; Gregory, T Stan; Boland, Brian L; Zhao, Wujun; Cheng, Rui; Mao, Leidong; Tse, Zion Tsz Ho

    2018-06-01

    Higher risk patient populations require continuous physiological monitoring and, in some cases, connected life-support systems, during magnetic resonance imaging examinations. While recently there has been a shift toward wireless technology, some of the magnetic resonance imaging devices are still connected to the outside using cabling that could interfere with the magnetic resonance imaging's radio frequency during scanning, resulting in excessive heating. We developed a passive method for radio frequency suppression on cabling that may assist in making some of these devices magnetic resonance imaging compatible. A barrel-shaped strongly paramagnetic choke was developed to suppress induced radio frequency signals which are overlaid onto physiological monitoring leads during magnetic resonance imaging. It utilized a choke placed along the signal lines, with a gadolinium solution core. The choke's magnetic susceptibility was modeled, for a given geometric design, at increasing chelate concentration levels, and measured using a vibrating sample magnetometer. Radio frequency noise suppression versus frequency was quantified with network-analyzer measurements and tested using cabling placed in the magnetic resonance imaging scanner. Temperature-elevation and image-quality reduction due to the device were measured using American Society for Testing and Materials phantoms. Prototype chokes with gadolinium solution cores exhibited increasing magnetic susceptibility, and insertion loss (S21) also showed higher attenuation as gadolinium concentration increased. Image artifacts extending <4 mm from the choke were observed during magnetic resonance imaging, which agreed well with the predicted ∼3 mm artifact from the electrochemical machining simulation. An accompanying temperature increase of <1 °C was observed in the magnetic resonance imaging phantom trial. An effective paramagnetic choke for radio frequency suppression during magnetic resonance imaging was developed and its performance demonstrated.

  12. Use of multi-coil parallel-gap resonators for co-registration EPR/NMR imaging

    NASA Astrophysics Data System (ADS)

    Kawada, Yuuki; Hirata, Hiroshi; Fujii, Hirodata

    2007-01-01

    This article reports experimental investigations on the use of RF resonators for continuous-wave electron paramagnetic resonance (cw-EPR) and proton nuclear magnetic resonance (NMR) imaging. We developed a composite resonator system with multi-coil parallel-gap resonators for co-registration EPR/NMR imaging. The resonance frequencies of each resonator were 21.8 MHz for NMR and 670 MHz for EPR. A smaller resonator (22 mm in diameter) for use in EPR was placed coaxially in a larger resonator (40 mm in diameter) for use in NMR. RF magnetic fields in the composite resonator system were visualized by measuring a homogeneous 4-hydroxy-2,2,6,6-tetramethyl-piperidinooxy (4-hydroxy-TEMPO) solution in a test tube. A phantom of five tubes containing distilled water and 4-hydroxy-TEMPO solution was also measured to demonstrate the potential usefulness of this composite resonator system in biomedical science. An image of unpaired electrons was obtained for 4-hydroxy-TEMPO in three tubes, and was successfully mapped on the proton image for five tubes. Technical problems in the implementation of a composite resonator system are discussed with regard to co-registration EPR/NMR imaging for animal experiments.

  13. Optimization of prostate biopsy: the role of magnetic resonance imaging targeted biopsy in detection, localization and risk assessment.

    PubMed

    Bjurlin, Marc A; Meng, Xiaosong; Le Nobin, Julien; Wysock, James S; Lepor, Herbert; Rosenkrantz, Andrew B; Taneja, Samir S

    2014-09-01

    Optimization of prostate biopsy requires addressing the shortcomings of standard systematic transrectal ultrasound guided biopsy, including false-negative rates, incorrect risk stratification, detection of clinically insignificant disease and the need for repeat biopsy. Magnetic resonance imaging is an evolving noninvasive imaging modality that increases the accurate localization of prostate cancer at the time of biopsy, and thereby enhances clinical risk assessment and improves the ability to appropriately counsel patients regarding therapy. In this review we 1) summarize the various sequences that comprise a prostate multiparametric magnetic resonance imaging examination along with its performance characteristics in cancer detection, localization and reporting standards; 2) evaluate potential applications of magnetic resonance imaging targeting in prostate biopsy among men with no previous biopsy, a negative previous biopsy and those with low stage cancer; and 3) describe the techniques of magnetic resonance imaging targeted biopsy and comparative study outcomes. A bibliographic search covering the period up to October 2013 was conducted using MEDLINE®/PubMed®. Articles were reviewed and categorized based on which of the 3 objectives of this review was addressed. Data were extracted, analyzed and summarized. Multiparametric magnetic resonance imaging consists of anatomical T2-weighted imaging coupled with at least 2 functional imaging techniques. It has demonstrated improved prostate cancer detection sensitivity up to 80% in the peripheral zone and 81% in the transition zone. A prostate cancer magnetic resonance imaging suspicion score has been developed, and is depicted using the Likert or PI-RADS (Prostate Imaging Reporting and Data System) scale for better standardization of magnetic resonance imaging interpretation and reporting. Among men with no previous biopsy, magnetic resonance imaging increases the frequency of significant cancer detection to 50% in low risk and 71% in high risk patients. In low risk men the negative predictive value of a combination of negative magnetic resonance imaging with prostate volume parameters is nearly 98%, suggesting a potential role in avoiding biopsy and reducing over detection/overtreatment. Among men with a previous negative biopsy 72% to 87% of cancers detected by magnetic resonance imaging guidance are clinically significant. Among men with a known low risk cancer, repeat biopsy using magnetic resonance targeting demonstrates a high likelihood of confirming low risk disease in low suspicion score lesions and of upgrading in high suspicion score lesions. Techniques of magnetic resonance imaging targeted biopsy include visual estimation transrectal ultrasound guided biopsy; software co-registered magnetic resonance imaging-ultrasound, transrectal ultrasound guided biopsy; and in-bore magnetic resonance imaging guided biopsy. Although the improvement in accuracy and efficiency of visual estimation biopsy compared to systematic appears limited, co-registered magnetic resonance imaging-ultrasound biopsy as well as in-bore magnetic resonance imaging guided biopsy appear to increase cancer detection rates in conjunction with increasing suspicion score. Use of magnetic resonance imaging for targeting prostate biopsies has the potential to reduce the sampling error associated with conventional biopsy by providing better disease localization and sampling. More accurate risk stratification through improved cancer sampling may impact therapeutic decision making. Optimal clinical application of magnetic resonance imaging targeted biopsy remains under investigation. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Comparison of radiography and magnetic resonance imaging for evaluating the extent of nasal neoplasia in dogs.

    PubMed

    Petite, A F B; Dennis, R

    2006-09-01

    Magnetic resonance imaging (MRI) is increasingly used in veterinary practice and, in some centres, is part of the diagnostic work-up of small animals with nasal disease. However, there are no published studies which critically evaluate the use of magnetic resonance imaging for this purpose. The purpose of this work was to assess the changes seen using magnetic resonance imaging and to compare them with radiography. The study included 12 dogs that had undergone both radiography and magnetic resonance imaging of the nasal cavity and had a histopathological diagnosis of malignant nasal neoplasia. Two pairs of board-certified radiologists scored the radiographs and the MRI scans, evaluating 10 signs of abnormality using a simple scoring system. Magnetic resonance imaging features were described in detail, and radiographic and magnetic resonance imaging scores for each sign as well as total scores were compared. Magnetic resonance imaging often showed that the tumour was more extensive than it had appeared on radiography but occasionally showed that radiographs had overestimated its size. Although radiography was reliable for assessment of the presence and size of a mass and for the extent of turbinate destruction, it usually failed to show occlusion of the major airway passages that were evident on magnetic resonance imaging. Extension of the tumour into the opposite nasal cavity, frontal sinus, orbit and cranial cavity was shown much better on magnetic resonance imaging. Minor but significant extension beyond the nasal cavity, which is important for treatment planning and prognosis, requires magnetic resonance imaging for demonstration, although radiography shows major changes reliably.

  15. The role of cardiovascular magnetic resonance in the assessment of severe aortic stenosis and in post-procedural evaluation following transcatheter aortic valve implantation and surgical aortic valve replacement.

    PubMed

    Musa, Tarique Al; Plein, Sven; Greenwood, John P

    2016-06-01

    Degenerative aortic stenosis (AS) is the most common valvular disease in the western world with a prevalence expected to double within the next 50 years. International guidelines advocate the use of cardiovascular magnetic resonance (CMR) as an investigative tool, both to guide diagnosis and to direct optimal treatment. CMR is the reference standard for quantifying both left and right ventricular volumes and mass, which is essential to assess the impact of AS upon global cardiac function. Given the ability to image any structure in any plane, CMR offers many other diagnostic strengths including full visualisation of valvular morphology, direct planimetry of orifice area, the quantification of stenotic jets and in particular, accurate quantification of valvular regurgitation. In addition, CMR permits reliable and accurate measurements of the aortic root and arch which can be fundamental to appropriate patient management. There is a growing evidence base to indicate tissue characterisation using CMR provides prognostic information, both in asymptomatic AS patients and those undergoing intervention. Furthermore, a number of current clinical trials will likely raise the importance of CMR in routine patient management. This article will focus on the incremental value of CMR in the assessment of severe AS and the insights it offers following valve replacement.

  16. Comparison of computed tomography and magnetic resonance imaging for the evaluation of canine intranasal neoplasia.

    PubMed

    Drees, R; Forrest, L J; Chappell, R

    2009-07-01

    Canine intranasal neoplasia is commonly evaluated using computed tomography to indicate the diagnosis, to determine disease extent, to guide histological sampling location and to plan treatment. With the expanding use of magnetic resonance imaging in veterinary medicine, this modality has been recently applied for the same purpose. The aim of this study was to compare the features of canine intranasal neoplasia using computed tomography and magnetic resonance imaging. Twenty-one dogs with confirmed intranasal neoplasia underwent both computed tomography and magnetic resonance imaging. The images were reviewed retrospectively for the bony and soft tissue features of intranasal neoplasia. Overall computed tomography and magnetic resonance imaging performed very similarly. However, lysis of bones bordering the nasal cavity and mucosal thickening was found on computed tomography images more often than on magnetic resonance images. Small amounts of fluid in the nasal cavity were more often seen on magnetic resonance images. However, fluid in the frontal sinuses was seen equally well with both modalities. We conclude that computed tomography is satisfactory for evaluation of canine intranasal neoplasia, and no clinically relevant benefit is gained using magnetic resonance imaging for intranasal neoplasia without extent into the cranial cavity.

  17. GIFTed Demons: deformable image registration with local structure-preserving regularization using supervoxels for liver applications

    PubMed Central

    Gleeson, Fergus V.; Brady, Michael; Schnabel, Julia A.

    2018-01-01

    Abstract. Deformable image registration, a key component of motion correction in medical imaging, needs to be efficient and provides plausible spatial transformations that reliably approximate biological aspects of complex human organ motion. Standard approaches, such as Demons registration, mostly use Gaussian regularization for organ motion, which, though computationally efficient, rule out their application to intrinsically more complex organ motions, such as sliding interfaces. We propose regularization of motion based on supervoxels, which provides an integrated discontinuity preserving prior for motions, such as sliding. More precisely, we replace Gaussian smoothing by fast, structure-preserving, guided filtering to provide efficient, locally adaptive regularization of the estimated displacement field. We illustrate the approach by applying it to estimate sliding motions at lung and liver interfaces on challenging four-dimensional computed tomography (CT) and dynamic contrast-enhanced magnetic resonance imaging datasets. The results show that guided filter-based regularization improves the accuracy of lung and liver motion correction as compared to Gaussian smoothing. Furthermore, our framework achieves state-of-the-art results on a publicly available CT liver dataset. PMID:29662918

  18. GIFTed Demons: deformable image registration with local structure-preserving regularization using supervoxels for liver applications.

    PubMed

    Papież, Bartłomiej W; Franklin, James M; Heinrich, Mattias P; Gleeson, Fergus V; Brady, Michael; Schnabel, Julia A

    2018-04-01

    Deformable image registration, a key component of motion correction in medical imaging, needs to be efficient and provides plausible spatial transformations that reliably approximate biological aspects of complex human organ motion. Standard approaches, such as Demons registration, mostly use Gaussian regularization for organ motion, which, though computationally efficient, rule out their application to intrinsically more complex organ motions, such as sliding interfaces. We propose regularization of motion based on supervoxels, which provides an integrated discontinuity preserving prior for motions, such as sliding. More precisely, we replace Gaussian smoothing by fast, structure-preserving, guided filtering to provide efficient, locally adaptive regularization of the estimated displacement field. We illustrate the approach by applying it to estimate sliding motions at lung and liver interfaces on challenging four-dimensional computed tomography (CT) and dynamic contrast-enhanced magnetic resonance imaging datasets. The results show that guided filter-based regularization improves the accuracy of lung and liver motion correction as compared to Gaussian smoothing. Furthermore, our framework achieves state-of-the-art results on a publicly available CT liver dataset.

  19. Magnetic Resonance Imaging of the Lung as an Alternative for a Pregnant Woman with Pulmonary Tuberculosis.

    PubMed

    Schloß, Manuel; Heckrodt, Jan; Schneider, Christian; Discher, Thomas; Krombach, Gabriele Anja

    2015-05-01

    We report a case of a pregnant 21-year-old woman with pulmonary tuberculosis in which magnetic resonance imaging of the lung was used to assess the extent and characteristics of the pathological changes. Although the lung has been mostly ignored in magnetic resonance imaging for many decades, today technical development enables detailed examinations of the lung. The technique is now entering the clinical arena and its indications are increasing. Magnetic resonance imaging of the lung is not only an alternative method without radiation exposure, it can provide additional information in pulmonary imaging compared to other modalities including computed tomography. We describe a successful application of magnetic resonance imaging of the lung and the imaging appearance of post-primary tuberculosis. This case report indicates that magnetic resonance imaging of the lung can potentially be the first choice imaging technique in pregnant women with suspected pulmonary tuberculosis.

  20. Tumor Size of Invasive Breast Cancer on Magnetic Resonance Imaging and Conventional Imaging (Mammogram/Ultrasound): Comparison with Pathological Size and Clinical Implications.

    PubMed

    Haraldsdóttir, K H; Jónsson, Þ; Halldórsdóttir, A B; Tranberg, K-G; Ásgeirsson, K S

    2017-03-01

    In Landspitali University Hospital, magnetic resonance imaging is used non-selectively in addition to mammogram and ultrasound in the preoperative assessment of breast cancer patients. The aim of this study was to assess invasive tumor size on imaging, compare with pathological size and evaluate the impact of magnetic resonance imaging on the type of surgery performed. All women with invasive breast cancer, diagnosed in Iceland, between 2007 and 2009 were reviewed retrospectively. In all, 438 of 641 (68%) patients diagnosed had preoperative magnetic resonance imaging. Twelve patients treated with neoadjuvant chemotherapy were excluded and 65 patients with multifocal or contralateral disease were assessed separately. Correlations between microscopic and radiologic tumor sizes were relatively weak. All imaging methods were inaccurate especially for large tumors, resulting in an overall underestimation of tumor size for these tumors. Magnetic resonance imaging under- and overestimated pathological tumor size by more than 10 mm in 16/348 (4.6%) and 26/348 patients (7.5%), respectively. In 19 patients (73%), overestimation of size was seen exclusively on magnetic resonance imaging. For tumors under- or overestimated by magnetic resonance imaging, the mastectomy rates were 56% and 65%, respectively, compared to an overall mastectomy rate of 43%. Of 51 patients diagnosed with multifocal disease on pathology, 19 (37%) were diagnosed by mammogram or ultrasound and 40 (78%) by magnetic resonance imaging resulting in a total detection rate of 84% (43 patients). Fourteen (3%) patients were diagnosed preoperatively with contralateral disease. Of those tumors, all were detected on magnetic resonance imaging but seven (50%) were also detected on mammogram or ultrasound or both. Our results suggest that routine use of magnetic resonance imaging may result in both under- and overestimation of tumor size and increase mastectomy rates in a small proportion of patients. Magnetic resonance imaging aids in the diagnosis of contralateral and multifocal disease.

  1. Legionella micdadei prosthetic valve endocarditis complicated by brain abscess: case report and review of the literature.

    PubMed

    Fukuta, Yuriko; Yildiz-Aktas, Isil Z; William Pasculle, A; Veldkamp, Peter J

    2012-06-01

    Legionella endocarditis is extremely uncommon, and embolic phenomena have never been reported. We report the first case of Legionella micdadei prosthetic valve endocarditis complicated by brain abscess. A 57-y-old immunocompromised woman with a history of mitral valve replacement developed confusion and left-sided weakness. Brain magnetic resonance imaging showed a 3-cm peripheral-enhancing mass. Transoesophageal echocardiography suggested a perivalvular abscess. Blood cultures and valve cultures were negative. She was diagnosed with 16S rRNA polymerase chain reaction and silver stain, and was discharged with levofloxacin after a redo mitral valve replacement. Twelve cases of Legionella endocarditis were reviewed. Only one case had a native valve, and her endocarditis occurred after pneumonia. All cases were cured. The duration of antibiotic therapy was variable. Legionella species should be considered in the differential diagnosis of culture-negative endocarditis in both immunocompetent and immunocompromised patients. Molecular techniques and silver impregnation stains are useful, especially when cultures using buffered charcoal-yeast extract agar are negative.

  2. Magnetic resonance imaging findings of cellular angiofibroma of the tunica vaginalis of the testis: a case report.

    PubMed

    Ntorkou, Alexandra A; Tsili, Athina C; Giannakis, Dimitrios; Batistatou, Anna; Stavrou, Sotirios; Sofikitis, Nikolaos; Argyropoulou, Maria I

    2016-03-31

    Cellular angiofibroma represents a rare mesenchymal tumor typically involving the inguinoscrotal area in middle-aged men. Although the origin of this benign tumor is unknown, it is histologically classified as an angiomyxoid tumor. Cellular angiofibroma is characterized by a diversity of pathological and imaging features. An accurate preoperative diagnosis is challenging. Magnetic resonance imaging examination of the scrotum has been reported as a valuable adjunct modality in the investigation of scrotal pathology. The technique by providing both structural and functional information is useful in the differentiation between extratesticular and intratesticular diseases and in the preoperative characterization of the histologic nature of various scrotal lesions. There are few reports in the English literature addressing the magnetic resonance imaging findings of cellular angiofibroma of the scrotum and no reports on functional magnetic resonance imaging data. Here we present the first case of a cellular angiofibroma arising from the tunica vaginalis of the testis and we discuss the value of a multiparametric magnetic resonance protocol, including diffusion-weighted imaging, magnetization transfer imaging and dynamic contrast-enhanced magnetic resonance imaging in the preoperative diagnosis of this rare neoplasm. A 47-year Greek man presented with a painless left scrotal swelling, which had gradually enlarged during the last 6 months. Magnetic resonance imaging of his scrotum displayed a left paratesticular mass, in close proximity to the tunica vaginalis, with heterogeneous high signal intensity on T2-weighted images and no areas of restricted diffusion. The tumor was hypointense on magnetization transfer images, suggestive for the presence of macromolecules. On dynamic contrast-enhanced magnetic resonance imaging the mass showed intense heterogeneous enhancement with a type II curve. Magnetic resonance imaging findings were strongly suggestive of a benign paratesticular tumor, which was confirmed on pathology following lesion excision. Magnetic resonance imaging of the scrotum by combining conventional and functional magnetic resonance data provides useful diagnostic information in the preoperative characterization of scrotal masses. A possible diagnosis of a benign paratesticular tumor based on magnetic resonance imaging features may improve patient care and decrease the number of unnecessary radical surgical explorations.

  3. Magnetic resonance imaging of blood-brain barrier permeability in ischemic stroke using diffusion-weighted arterial spin labeling in rats.

    PubMed

    Tiwari, Yash V; Lu, Jianfei; Shen, Qiang; Cerqueira, Bianca; Duong, Timothy Q

    2017-08-01

    Diffusion-weighted arterial spin labeling magnetic resonance imaging has recently been proposed to quantify the rate of water exchange (K w ) across the blood-brain barrier in humans. This study aimed to evaluate the blood-brain barrier disruption in transient (60 min) ischemic stroke using K w magnetic resonance imaging with cross-validation by dynamic contrast-enhanced magnetic resonance imaging and Evans blue histology in the same rats. The major findings were: (i) at 90 min after stroke (30 min after reperfusion), group K w magnetic resonance imaging data showed no significant blood-brain barrier permeability changes, although a few animals showed slightly abnormal K w . Dynamic contrast-enhanced magnetic resonance imaging confirmed this finding in the same animals. (ii) At two days after stroke, K w magnetic resonance imaging revealed significant blood-brain barrier disruption. Regions with abnormal K w showed substantial overlap with regions of hyperintense T 2 (vasogenic edema) and hyperperfusion. Dynamic contrast-enhanced magnetic resonance imaging and Evans blue histology confirmed these findings in the same animals. The K w values in the normal contralesional hemisphere and the ipsilesional ischemic core two days after stroke were: 363 ± 17 and 261 ± 18 min -1 , respectively (P < 0.05, n = 9). K w magnetic resonance imaging is sensitive to blood-brain barrier permeability changes in stroke, consistent with dynamic contrast-enhanced magnetic resonance imaging and Evans blue extravasation. K w magnetic resonance imaging offers advantages over existing techniques because contrast agent is not needed and repeated measurements can be made for longitudinal monitoring or averaging.

  4. Adjunctive role of preoperative liver magnetic resonance imaging for potentially resectable pancreatic cancer.

    PubMed

    Kim, Hyoung Woo; Lee, Jong-Chan; Paik, Kyu-Hyun; Kang, Jingu; Kim, Young Hoon; Yoon, Yoo-Seok; Han, Ho-Seong; Kim, Jaihwan; Hwang, Jin-Hyeok

    2017-06-01

    The adjunctive role of magnetic resonance imaging of the liver before pancreatic ductal adenocarcinoma has been unclear. We evaluated whether the combination of hepatic magnetic resonance imaging with multidetector computed tomography using a pancreatic protocol (pCT) could help surgeons select appropriate candidates and decrease the risk of early recurrence. We retrospectively enrolled 167 patients in whom complete resection was achieved without grossly visible residual tumor; 102 patients underwent pCT alone (CT group) and 65 underwent both hepatic magnetic resonance imaging and pCT (magnetic resonance imaging group). By adding hepatic magnetic resonance imaging during preoperative evaluation, hepatic metastases were newly discovered in 3 of 58 patients (5%) without hepatic lesions on pCT and 17 of 53 patients (32%) with indeterminate hepatic lesions on pCT. Patients with borderline resectability, a tumor size >3 cm, or preoperative carbohydrate antigen 19-9 level >1,000 U/mL had a greater rate of hepatic metastasis on subsequent hepatic magnetic resonance imaging. Among 167 patients in whom R0/R1 resection was achieved, the median overall survival was 18.2 vs 24.7 months (P = .020) and the disease-free survival was 8.5 vs 10.0 months (P = .016) in the CT and magnetic resonance imaging groups, respectively (median follow-up, 18.3 months). Recurrence developed in 82 (80%) and 43 (66%) patients in the CT and magnetic resonance imaging groups, respectively. The cumulative hepatic recurrence rate was greater in the CT group than in the magnetic resonance imaging group (P < .001). Preoperative hepatic magnetic resonance imaging should be considered in patients with potentially resectable pancreatic ductal adenocarcinoma, especially those with high tumor burden. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Ultrahigh field magnetic resonance and colour Doppler real-time fusion imaging of the orbit--a hybrid tool for assessment of choroidal melanoma.

    PubMed

    Walter, Uwe; Niendorf, Thoralf; Graessl, Andreas; Rieger, Jan; Krüger, Paul-Christian; Langner, Sönke; Guthoff, Rudolf F; Stachs, Oliver

    2014-05-01

    A combination of magnetic resonance images with real-time high-resolution ultrasound known as fusion imaging may improve ophthalmologic examination. This study was undertaken to evaluate the feasibility of orbital high-field magnetic resonance and real-time colour Doppler ultrasound image fusion and navigation. This case study, performed between April and June 2013, included one healthy man (age, 47 years) and two patients (one woman, 57 years; one man, 67 years) with choroidal melanomas. All cases underwent 7.0-T magnetic resonance imaging using a custom-made ocular imaging surface coil. The Digital Imaging and Communications in Medicine volume data set was then loaded into the ultrasound system for manual registration of the live ultrasound image and fusion imaging examination. Data registration, matching and then volume navigation were feasible in all cases. Fusion imaging provided real-time imaging capabilities and high tissue contrast of choroidal tumour and optic nerve. It also allowed adding a real-time colour Doppler signal on magnetic resonance images for assessment of vasculature of tumour and retrobulbar structures. The combination of orbital high-field magnetic resonance and colour Doppler ultrasound image fusion and navigation is feasible. Multimodal fusion imaging promises to foster assessment and monitoring of choroidal melanoma and optic nerve disorders. • Orbital magnetic resonance and colour Doppler ultrasound real-time fusion imaging is feasible • Fusion imaging combines the spatial and temporal resolution advantages of each modality • Magnetic resonance and ultrasound fusion imaging improves assessment of choroidal melanoma vascularisation.

  6. Diagnostic value of three-dimensional magnetic resonance imaging of inner ear after intratympanic gadolinium injection, and clinical application of magnetic resonance imaging scoring system in patients with delayed endolymphatic hydrops.

    PubMed

    Gu, X; Fang, Z-M; Liu, Y; Lin, S-L; Han, B; Zhang, R; Chen, X

    2014-01-01

    Three-dimensional fluid-attenuated inversion recovery magnetic resonance imaging of the inner ear after intratympanic injection of gadolinium, together with magnetic resonance imaging scoring of the perilymphatic space, were used to investigate the positive identification rate of hydrops and determine the technique's diagnostic value for delayed endolymphatic hydrops. Twenty-five patients with delayed endolymphatic hydrops underwent pure tone audiometry, bithermal caloric testing, vestibular-evoked myogenic potential testing and three-dimensional magnetic resonance imaging of the inner ear after bilateral intratympanic injection of gadolinium. The perilymphatic space of the scanned images was analysed to investigate the positive identification rate of endolymphatic hydrops. According to the magnetic resonance imaging scoring of the perilymphatic space and the diagnostic standard, 84 per cent of the patients examined had endolymphatic hydrops. In comparison, the positive identification rates for vestibular-evoked myogenic potential and bithermal caloric testing were 52 per cent and 72 per cent respectively. Three-dimensional magnetic resonance imaging after intratympanic injection of gadolinium is valuable in the diagnosis of delayed endolymphatic hydrops and its classification. The perilymphatic space scoring system improved the diagnostic accuracy of magnetic resonance imaging.

  7. The utility of ultrasound and magnetic resonance imaging versus surgery for the characterization of müllerian anomalies in the pediatric and adolescent population.

    PubMed

    Santos, X M; Krishnamurthy, R; Bercaw-Pratt, J L; Dietrich, J E

    2012-06-01

    To evaluate the utility of transabdominal ultrasound and magnetic resonance imaging in the evaluation of American Society for Reproductive Medicine (†)(ASRM)-classified müllerian anomalies compared to surgical findings in the pediatric and adolescent population. Retrospective chart review. Tertiary academic center. Thirty-eight patients with müllerian anomalies seen in our pediatric and adolescent gynecology clinic were identified both on the basis of ICD-9 codes and having magnetic resonance imaging at Texas Children's Hospital between 2004 and 2009. None. Correlation among transabdominal ultrasound and magnetic resonance imaging findings with surgical findings. Mean age was 12.2 (± 4.1) years. Twenty-eight patients underwent magnetic resonance imaging and required surgical intervention, and 88.5% demonstrated correlative consistency with surgical findings. Twenty-two patients underwent ultrasound, magnetic resonance imaging, and surgery, which revealed consistency among ultrasound and surgical findings (59.1%) and consistency among magnetic resonance imaging and surgical findings (90.9%). In ASRM diagnoses evaluated by magnetic resonance imaging, surgical findings correlated in 92% (Pearson 0.89). Overall, 55.2% of patients had a renal malformation. Magnetic resonance imaging is the gold standard imaging modality for müllerian anomalies and is an effective technique for noninvasive evaluation and accurate classification of the type of anomaly in the pediatric and adolescent population. Magnetic resonance imaging should be considered as an adjunct to transabdominal ultrasound to evaluate müllerian anomalies. Copyright © 2012 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  8. Fully convolutional networks (FCNs)-based segmentation method for colorectal tumors on T2-weighted magnetic resonance images.

    PubMed

    Jian, Junming; Xiong, Fei; Xia, Wei; Zhang, Rui; Gu, Jinhui; Wu, Xiaodong; Meng, Xiaochun; Gao, Xin

    2018-06-01

    Segmentation of colorectal tumors is the basis of preoperative prediction, staging, and therapeutic response evaluation. Due to the blurred boundary between lesions and normal colorectal tissue, it is hard to realize accurate segmentation. Routinely manual or semi-manual segmentation methods are extremely tedious, time-consuming, and highly operator-dependent. In the framework of FCNs, a segmentation method for colorectal tumor was presented. Normalization was applied to reduce the differences among images. Borrowing from transfer learning, VGG-16 was employed to extract features from normalized images. We conducted five side-output blocks from the last convolutional layer of each block of VGG-16 along the network, these side-output blocks can deep dive multiscale features, and produced corresponding predictions. Finally, all of the predictions from side-output blocks were fused to determine the final boundaries of the tumors. A quantitative comparison of 2772 colorectal tumor manual segmentation results from T2-weighted magnetic resonance images shows that the average Dice similarity coefficient, positive predictive value, specificity, sensitivity, Hammoude distance, and Hausdorff distance were 83.56, 82.67, 96.75, 87.85%, 0.2694, and 8.20, respectively. The proposed method is superior to U-net in colorectal tumor segmentation (P < 0.05). There is no difference between cross-entropy loss and Dice-based loss in colorectal tumor segmentation (P > 0.05). The results indicate that the introduction of FCNs contributed to accurate segmentation of colorectal tumors. This method has the potential to replace the present time-consuming and nonreproducible manual segmentation method.

  9. Micro-magnetic resonance imaging study of live quail embryos during embryonic development.

    PubMed

    Duce, Suzanne; Morrison, Fiona; Welten, Monique; Baggott, Glenn; Tickle, Cheryll

    2011-01-01

    Eggs containing live Japanese quail embryos were imaged using micro-magnetic resonance imaging (μMRI) at 24-h intervals from Day 0 to 8, the period during which the main body axis is being laid down and organogenesis is taking place. Considerable detail of non-embryonic structures such as the latebra was revealed at early stages but the embryo could only be visualized around Day 3. Three-dimensional (3D) changes in embryo length and volume were quantified and also changes in volume in the extra- and non-embryonic components. The embryo increased in length by 43% and nearly trebled in volume between Day 4 and Day 5. Although the amount of yolk remained fairly constant over the first 5 days, the amount of albumen decreases significantly and was replaced by extra-embryonic fluid (EEF). ¹H longitudinal (T₁) and transverse (T₂) relaxation times of different regions within the eggs were determined over the first 6 days of development. The T₂ measurements mirrored the changes in image intensity observed, which can be related to the aqueous protein concentrations. In addition, a comparison of the development of Day 0 to 3 quail embryos exposed to radiofrequency (rf) pulses, 7 T static magnetic fields and magnetic field gradients for an average of 7 h with the development of control embryos did not reveal any gross changes, thus confirming that μMRI is a suitable tool for following the development of live avian embryos over time from the earliest stages. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Left ventricular hypertrophy: The relationship between the electrocardiogram and cardiovascular magnetic resonance imaging.

    PubMed

    Bacharova, Ljuba; Ugander, Martin

    2014-11-01

    Conventional assessment of left ventricular hypertrophy (LVH) using the electrocardiogram (ECG), for example, by the Sokolow-Lyon, Romhilt-Estes or Cornell criteria, have relied on assessing changes in the amplitude and/or duration of the QRS complex of the ECG to quantify LV mass. ECG measures of LV mass have typically been validated by imaging with echocardiography or cardiovascular magnetic resonance imaging (CMR). However, LVH can be the result of diverse etiologies, and LVH is also characterized by pathological changes in myocardial tissue characteristics on the genetic, molecular, cellular, and tissue level beyond a pure increase in the number of otherwise normal cardiomyocytes. For example, slowed conduction velocity through the myocardium, which can be due to diffuse myocardial fibrosis, has been shown to be an important determinant of conventional ECG LVH criteria regardless of LV mass. Myocardial tissue characterization by CMR has emerged to not only quantify LV mass, but also detect and quantify the extent and severity of focal or diffuse myocardial fibrosis, edema, inflammation, myocarditis, fatty replacement, myocardial disarray, and myocardial deposition of amyloid proteins (amyloidosis), glycolipids (Fabry disease), or iron (siderosis). This can be undertaken using CMR techniques including late gadolinium enhancement (LGE), T1 mapping, T2 mapping, T2* mapping, extracellular volume fraction (ECV) mapping, fat/water-weighted imaging, and diffusion tensor CMR. This review presents an overview of current and emerging concepts regarding the diagnostic possibilities of both ECG and CMR for LVH in an attempt to narrow gaps in our knowledge regarding the ECG diagnosis of LVH. © 2014 Wiley Periodicals, Inc.

  11. Liver acquisition with acceleration volume acquisition gadolinium-enhanced magnetic resonance combined with T2 sequences in the diagnosis of local recurrence of rectal cancer.

    PubMed

    Cao, Wuteng; Li, Fangqian; Gong, Jiaying; Liu, Dechao; Deng, Yanhong; Kang, Liang; Zhou, Zhiyang

    2016-11-22

    To investigate the efficacy of liver acquisition with acceleration volume acquisition (LAVA) gadolinium-enhanced magnetic resonance (MR) sequences and to assess its added accuracy in diagnosing local recurrence (LR) of rectal cancer with conventional T2-weighted fast spin echo (FSE) sequences. Pelvic MRI, including T2-weighted FSE sequences, gadolinium-enhanced sequences of LAVA and T1-weighted FSE with fat suppression, was performed on 225 patients with postoperative rectal cancer. Two readers evaluated the presence of LR according to "T2" (T2 sequences only), "T2 + LAVA-Gad" (LAVA and T2 imaging), and "T2 + T1-fs-Gad" (T1 fat suppression-enhanced sequence with T2 images). To evaluate diagnostic efficiency, imaging quality with LAVA and T1-fs-Gad by subjective scores and the signal intensity (SI) ratio. In the result, the SI ratio of LAVA was significantly higher than that of T1-fs-Gad (p = 0.0001). The diagnostic efficiency of "T2 + LAVA-Gad" was better than that of "T2 + T1-fs-Gad" (p = 0.0016 for Reader 1, p = 0.0001 for Reader 2) and T2 imaging only (p = 0.0001 for Reader 1; p = 0.0001 for Reader 2). Therefore, LAVA gadolinium-enhanced MR increases the accuracy of diagnosis of LR from rectal cancer and could replace conventional T1 gadolinium-enhanced sequences in the postoperative pelvic follow-up of rectal cancer.

  12. Comparison of magnetic resonance imaging and computed tomography in suspected lesions in the posterior cranial fossa.

    PubMed Central

    Teasdale, G. M.; Hadley, D. M.; Lawrence, A.; Bone, I.; Burton, H.; Grant, R.; Condon, B.; Macpherson, P.; Rowan, J.

    1989-01-01

    OBJECTIVE--To compare computed tomography and magnetic resonance imaging in investigating patients suspected of having a lesion in the posterior cranial fossa. DESIGN--Randomised allocation of newly referred patients to undergo either computed tomography or magnetic resonance imaging; the alternative investigation was performed subsequently only in response to a request from the referring doctor. SETTING--A regional neuroscience centre serving 2.7 million. PATIENTS--1020 Patients recruited between April 1986 and December 1987, all suspected by neurologists, neurosurgeons, or other specialists of having a lesion in the posterior fossa and referred for neuroradiology. The groups allocated to undergo computed tomography or magnetic resonance imaging were well matched in distributions of age, sex, specialty of referring doctor, investigation as an inpatient or an outpatient, suspected site of lesion, and presumed disease process; the referring doctor's confidence in the initial clinical diagnosis was also similar. INTERVENTIONS--After the patients had been imaged by either computed tomography or magnetic resonance (using a resistive magnet of 0.15 T) doctors were given the radiologist's report and a form asking if they considered that imaging with the alternative technique was necessary and, if so, why; it also asked for their current diagnoses and their confidence in them. MAIN OUTCOME MEASURES--Number of requests for the alternative method of investigation. Assessment of characteristics of patients for whom further imaging was requested and lesions that were suspected initially and how the results of the second imaging affected clinicians' and radiologists' opinions. RESULTS--Ninety three of the 501 patients who initially underwent computed tomography were referred subsequently for magnetic resonance imaging whereas only 28 of the 493 patients who initially underwent magnetic resonance imaging were referred subsequently for computed tomography. Over the study the number of patients referred for magnetic resonance imaging after computed tomography increased but requests for computed tomography after magnetic resonance imaging decreased. The reason that clinicians gave most commonly for requesting further imaging by magnetic resonance was that the results of the initial computed tomography failed to exclude their suspected diagnosis (64 patients). This was less common in patients investigated initially by magnetic resonance imaging (eight patients). Management of 28 patients (6%) imaged initially with computed tomography and 12 patients (2%) imaged initially with magnetic resonance was changed on the basis of the results of the alternative imaging. CONCLUSIONS--Magnetic resonance imaging provided doctors with the information required to manage patients suspected of having a lesion in the posterior fossa more commonly than computed tomography, but computed tomography alone was satisfactory in 80% of cases... PMID:2506965

  13. Imaging anatomy of the vestibular and visual systems.

    PubMed

    Gunny, Roxana; Yousry, Tarek A

    2007-02-01

    This review will outline the imaging anatomy of the vestibular and visual pathways, using computed tomography and magnetic resonance imaging, with emphasis on the more recent developments in neuroimaging. Technical advances in computed tomography and magnetic resonance imaging, such as the advent of multislice computed tomography and newer magnetic resonance imaging techniques such as T2-weighted magnetic resonance cisternography, have improved the imaging of the vestibular and visual pathways, allowing better visualization of the end organs and peripheral nerves. Higher field strength magnetic resonance imaging is a promising tool, which has been used to evaluate and resolve fine anatomic detail in vitro, as in the labyrinth. Advanced magnetic resonance imaging techniques such as functional magnetic resonance imaging and diffusion tractography have been used to identify cortical areas of activation and associated white matter pathways, and show potential for the future identification of complex neuronal relays involved in integrating these pathways. The assessment of the various components of the vestibular and the visual systems has improved with more detailed research on the imaging anatomy of these systems, the advent of high field magnetic resonance scanners and multislice computerized tomography, and the wider use of specific techniques such as tractography which displays white matter tracts not directly accessible until now.

  14. Comparison of computed tomography and magnetic resonance imaging for the evaluation of canine intranasal neoplasia

    PubMed Central

    Drees, R.; Forrest, L. J.; Chappell, R.

    2009-01-01

    Objectives Canine intranasal neoplasia is commonly evaluated using computed tomography to indicate the diagnosis, to determine disease extent, to guide histological sampling location and to plan treatment. With the expanding use of magnetic resonance imaging in veterinary medicine, this modality has been recently applied for the same purpose. The aim of this study was to compare the features of canine intranasal neoplasia using computed tomography and magnetic resonance imaging. Methods Twenty-one dogs with confirmed intranasal neoplasia underwent both computed tomography and magnetic resonance imaging. The images were reviewed retrospectively for the bony and soft tissue features of intranasal neoplasia. Results Overall computed tomography and magnetic resonance imaging performed very similarly. However, lysis of bones bordering the nasal cavity and mucosal thickening was found on computed tomography images more often than on magnetic resonance images. Small amounts of fluid in the nasal cavity were more often seen on magnetic resonance images. However, fluid in the frontal sinuses was seen equally well with both modalities. Clinical Significance We conclude that computed tomography is satisfactory for evaluation of canine intranasal neoplasia, and no clinically relevant benefit is gained using magnetic resonance imaging for intranasal neoplasia without extent into the cranial cavity. PMID:19508490

  15. Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

    NASA Technical Reports Server (NTRS)

    Lang, P.; Genant, H. K.; Jergesen, H. E.; Murray, W. R.

    1992-01-01

    The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

  16. Fluorescence imaging as a diagnostic of M-band x-ray drive condition in hohlraum with fluorescent Si targets

    NASA Astrophysics Data System (ADS)

    Li, Qi; Hu, Zhimin; Yao, Li; Huang, Chengwu; Yuan, Zheng; Zhao, Yang; Xiong, Gang; Qing, Bo; Lv, Min; Zhu, Tuo; Deng, Bo; Li, Jin; Wei, Minxi; Zhan, Xiayu; Li, Jun; Yang, Yimeng; Su, Chunxiao; Yang, Guohong; Zhang, Jiyan; Li, Sanwei; Yang, Jiamin; Ding, Yongkun

    2017-01-01

    Fluorescence imaging of surrogate Si-doped CH targets has been used to provide a measurement for drive condition of high-energy x-ray (i.e. M-band x-ray) drive symmetry upon the capsule in hohlraum on Shenguang-II laser facility. A series of experiments dedicated to the study of photo-pumping and fluorescence effect in Si-plasma are presented. To investigate the feasibility of fluorescence imaging in Si-plasma, an silicon plasma in Si-foil target is pre-formed at ground state by the soft x-ray from a half-hohlraum, which is then photo-pumped by the K-shell lines from a spatially distinct laser-produced Si-plasma. The resonant Si photon pump is used to improve the fluorescence signal and cause visible image in the Si-foil. Preliminary fluorescence imaging of Si-ball target is performed in both Si-doped and pure Au hohlraum. The usual capsule at the center of the hohlraum is replaced with a solid Si-doped CH-ball (Si-ball). Since the fluorescence is proportional to the photon pump upon the Si-plasma, high-energy x-ray drive symmetry is equal to the fluorescence distribution of the Si-ball.

  17. Brain Magnetic Resonance Imaging as First-Line Investigation for Growth Hormone Deficiency Diagnosis in Early Childhood.

    PubMed

    Pampanini, Valentina; Pedicelli, Stefania; Gubinelli, Jessica; Scirè, Giuseppe; Cappa, Marco; Boscherini, Brunetto; Cianfarani, Stefano

    2015-01-01

    The diagnosis of growth hormone (GH) deficiency (GHD) in infancy and early childhood is not straightforward. GH stimulation tests are unsafe and unreliable in infants, and normative data are lacking. This study aims to investigate whether brain magnetic resonance imaging (MRI) may replace GH stimulation tests in the diagnosis of GHD in children younger than 4 years. We examined a retrospective cohort, with longitudinal follow-up, of 68 children consecutively diagnosed with GHD before the age of 4 years. The prevalence of hypothalamic-pituitary (HP) alterations at MRI and the associations with age and either isolated GHD (IGHD) or multiple pituitary hormone deficiency (MPHD) were assessed. The prevalences of IGHD and MPHD were 54.4 and 45.6%, respectively. In the first group, brain MRI showed abnormalities in 83.8%: isolated pituitary hypoplasia in 48.7% and complex defects in 35.1%. In patients with MPHD, MRI showed complex alterations in 100%. All children younger than 24 months showed HP MRI abnormalities, regardless of the diagnosis. Complex defects were found in 94% of patients younger than 12 months and in 75% of patients between 13 and 24 months. Our data suggest that brain MRI may represent the first-line investigation for diagnosing GHD in infancy and early childhood. © 2015 S. Karger AG, Basel.

  18. Neuroimaging and obesity: current knowledge and future directions

    PubMed Central

    Carnell, S.; Gibson, C.; Benson, L.; Ochner, C. N.; Geliebter, A.

    2011-01-01

    Summary Neuroimaging is becoming increasingly common in obesity research as investigators try to understand the neurological underpinnings of appetite and body weight in humans. Positron emission tomography (PET), functional magnetic resonance imaging (fMRI) and magnetic resonance imaging (MRI) studies examining responses to food intake and food cues, dopamine function and brain volume in lean vs. obese individuals are now beginning to coalesce in identifying irregularities in a range of regions implicated in reward (e.g. striatum, orbitofrontal cortex, insula), emotion and memory (e.g. amygdala, hippocampus), homeostatic regulation of intake (e.g. hypothalamus), sensory and motor processing (e.g. insula, precentral gyrus), and cognitive control and attention (e.g. prefrontal cortex, cingulate). Studies of weight change in children and adolescents, and those at high genetic risk for obesity, promise to illuminate causal processes. Studies examining specific eating behaviours (e.g. external eating, emotional eating, dietary restraint) are teaching us about the distinct neural networks that drive components of appetite, and contribute to the phenotype of body weight. Finally, innovative investigations of appetite-related hormones, including studies of abnormalities (e.g. leptin deficiency) and interventions (e.g. leptin replacement, bariatric surgery), are shedding light on the interactive relationship between gut and brain. The dynamic distributed vulnerability model of eating behaviour in obesity that we propose has scientific and practical implications. PMID:21902800

  19. Magnetic resonance imaging in the evaluation of sports injuries of the foot and ankle: a pictorial essay.

    PubMed

    Riley, Geoffrey M

    2007-01-01

    Magnetic resonance imaging is playing an increasingly important role in evaluation of the injured athlete's foot and ankle. Magnetic resonance imaging allows accurate detection of bony abnormalities, such as stress fractures, and soft-tissue abnormalities, including ligament tears, tendon tears, and tendinopathy. The interpreter of magnetic resonance images should systematically review the images, noting normal structures and accounting for changes in soft-tissue and bony signal.

  20. Pulse Coupled Neural Networks for the Segmentation of Magnetic Resonance Brain Images.

    DTIC Science & Technology

    1996-12-01

    PULSE COUPLED NEURAL NETWORKS FOR THE SEGMENTATION OF MAGNETIC RESONANCE BRAIN IMAGES THESIS Shane Lee Abrahamson First Lieutenant, USAF AFIT/GCS/ENG...COUPLED NEURAL NETWORKS FOR THE SEGMENTATION OF MAGNETIC RESONANCE BRAIN IMAGES THESIS Shane Lee Abrahamson First Lieutenant, USAF AFIT/GCS/ENG/96D-01...research develops an automated method for segmenting Magnetic Resonance (MR) brain images based on Pulse Coupled Neural Networks (PCNN). MR brain image

  1. Magnetic Resonance-Based Electrical Property Tomography (MR-EPT) for Prostate Cancer Grade Imaging

    DTIC Science & Technology

    2016-07-01

    Award Number: W81XWH-13-1-0127 TITLE: Magnetic Resonance-Based Electrical Property Tomography (MR- EPT) for Prostate Cancer Grade Imaging...SUBTITLE 5a. CONTRACT NUMBER W81XWH-13-1-0127 Magnetic Resonance-Based Electrical Property Tomography (MR- EPT) for Prostate Cancer Grade Imaging...developing Magnetic Resonance – Electrical Property Tomography (MR-EPT) specifically for prostate imaging. MR-EPT is an imaging modality that may enable

  2. Four-channel surface coil array for sequential CW-EPR image acquisition

    NASA Astrophysics Data System (ADS)

    Enomoto, Ayano; Emoto, Miho; Fujii, Hirotada; Hirata, Hiroshi

    2013-09-01

    This article describes a four-channel surface coil array to increase the area of visualization for continuous-wave electron paramagnetic resonance (CW-EPR) imaging. A 776-MHz surface coil array was constructed with four independent surface coil resonators and three kinds of switches. Control circuits for switching the resonators were also built to sequentially perform EPR image acquisition for each resonator. The resonance frequencies of the resonators were shifted using PIN diode switches to decouple the inductively coupled coils. To investigate the area of visualization with the surface coil array, three-dimensional EPR imaging was performed using a glass cell phantom filled with a solution of nitroxyl radicals. The area of visualization obtained with the surface coil array was increased approximately 3.5-fold in comparison to that with a single surface coil resonator. Furthermore, to demonstrate the applicability of this surface coil array to animal imaging, three-dimensional EPR imaging was performed in a living mouse with an exogenously injected nitroxyl radical imaging agent.

  3. Correlating MALDI and MRI Biomarkers of Breast Cancer

    DTIC Science & Technology

    2010-07-01

    resonance imaging ( MRI ) with matrix-assisted laser desorption ionization (MALDI) analysis of healthy and tumorous ex vivo specimens in order to examine the...assess the correlation between physiological parameters reported by magnetic resonance (MR) imaging and tumor protein distribution determined from... imaging research (e.g., Cancer Imaging , Quantitative Magnetic Resonance Imaging , and Medical Image Registration classes) • completion of

  4. Recent Advances in Cardiovascular Magnetic Resonance Techniques and Applications

    PubMed Central

    Salerno, Michael; Sharif, Behzad; Arheden, Håkan; Kumar, Andreas; Axel, Leon; Li, Debiao; Neubauer, Stefan

    2018-01-01

    Cardiovascular magnetic resonance imaging has become the gold standard for evaluating myocardial function, volumes, and scarring. Additionally, cardiovascular magnetic resonance imaging is unique in its comprehensive tissue characterization, including assessment of myocardial edema, myocardial siderosis, myocardial perfusion, and diffuse myocardial fibrosis. Cardiovascular magnetic resonance imaging has become an indispensable tool in the evaluation of congenital heart disease, heart failure, cardiac masses, pericardial disease, and coronary artery disease. This review will highlight some recent novel cardiovascular magnetic resonance imaging techniques, concepts, and applications. PMID:28611116

  5. Simple and Inexpensive Classroom Demonstrations of Nuclear Magnetic Resonance and Magnetic Resonance Imaging.

    ERIC Educational Resources Information Center

    Olson, Joel A.; Nordell, Karen J.; Chesnik, Marla A.; Landis, Clark R.; Ellis, Arthur B.; Rzchowski, M. S.; Condren, S. Michael; Lisensky, George C.

    2000-01-01

    Describes a set of simple, inexpensive, classical demonstrations of nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) principles that illustrate the resonance condition associated with magnetic dipoles and the dependence of the resonance frequency on environment. (WRM)

  6. A novel paramagnetic substrate for detecting myeloperoxidase activity in vivo.

    PubMed

    Shazeeb, Mohammed S; Xie, Yang; Gupta, Suresh; Bogdanov, Alexei A

    2012-01-01

    Bis-phenylamides and bis-hydroxyindolamides of diethylenetriaminepentaacetic acid-gadolinium (DTPA(Gd)) are paramagnetic reducing substrates of peroxidases that enable molecular imaging of peroxidase activity in vivo. Specifically, gadolinium chelates of bis-5-hydroxytryptamide-DTPA (bis-5HT-DTPA(Gd)) have been used to image localized inflammation in animal models by detecting neutrophil-derived myeloperoxidase (MPO) activity at the inflammation site. However, in other preclinical disease models, bis-5HT-DTPA(Gd) presents technical challenges due to its limited solubility in vivo. Here we report a novel MPO-sensing probe obtained by replacing the reducing substrate serotonin (5-HT) with 5-hydroxytryptophan (HTrp). Characterization of the resulting probe (bis-HTrp-DTPA(Gd)) in vitro using nuclear magnetic resonance spectroscopy and enzyme kinetic analysis showed that bis-HTrp-DTPA(Gd) (1) improves solubility in water; (2) acts as a substrate for both horseradish peroxidase and MPO enzymes; (3) induces cross-linking of proteins in the presence of MPO; (4) produces oxidation products, which bind to plasma proteins; and (5) unlike bis-5HT-DTPA(Gd), does not follow first-order reaction kinetics. In vivo magnetic resonance imaging (MRI) in mice demonstrated that bis-HTrp-DTPA(Gd) was retained for up to 5 days in MPO-containing sites and cleared faster than bis-5HT-DTPA(Gd) from MPO-negative sites. Bis-HTrp-DTPA(Gd) should offer improvements for MRI of MPO-mediated inflammation in vivo, especially in high-field MRI, which requires a higher dose of contrast agent.

  7. Use magnetic resonance imaging to assess articular cartilage

    PubMed Central

    Wang, Yuanyuan; Wluka, Anita E.; Jones, Graeme; Ding, Changhai

    2012-01-01

    Magnetic resonance imaging (MRI) enables a noninvasive, three-dimensional assessment of the entire joint, simultaneously allowing the direct visualization of articular cartilage. Thus, MRI has become the imaging modality of choice in both clinical and research settings of musculoskeletal diseases, particular for osteoarthritis (OA). Although radiography, the current gold standard for the assessment of OA, has had recent significant technical advances, radiographic methods have significant limitations when used to measure disease progression. MRI allows accurate and reliable assessment of articular cartilage which is sensitive to change, providing the opportunity to better examine and understand preclinical and very subtle early abnormalities in articular cartilage, prior to the onset of radiographic disease. MRI enables quantitative (cartilage volume and thickness) and semiquantitative assessment of articular cartilage morphology, and quantitative assessment of cartilage matrix composition. Cartilage volume and defects have demonstrated adequate validity, accuracy, reliability and sensitivity to change. They are correlated to radiographic changes and clinical outcomes such as pain and joint replacement. Measures of cartilage matrix composition show promise as they seem to relate to cartilage morphology and symptoms. MRI-derived cartilage measurements provide a useful tool for exploring the effect of modifiable factors on articular cartilage prior to clinical disease and identifying the potential preventive strategies. MRI represents a useful approach to monitoring the natural history of OA and evaluating the effect of therapeutic agents. MRI assessment of articular cartilage has tremendous potential for large-scale epidemiological studies of OA progression, and for clinical trials of treatment response to disease-modifying OA drugs. PMID:22870497

  8. Grading of inflammatory disease activity in the sacroiliac joints with magnetic resonance imaging: comparison between short-tau inversion recovery and gadolinium contrast-enhanced sequences.

    PubMed

    Madsen, Karen Berenth; Egund, Niels; Jurik, Anne Grethe

    2010-02-01

    We investigated the potential concordance of 2 different magnetic resonance (MR) sequences - short-tau inversion recovery (STIR) and fat-saturated T1-weighted spin-echo after application of gadolinium (Gd) contrast medium to detect active bone marrow abnormalities at the sacroiliac joints (SIJ) in patients with spondyloarthritis (SpA). Blinded and using the Danish scoring method, we evaluated transaxial MR images of the 2 sequences in 40 patients with SpA with disease duration of 3-14 years. Both the cartilaginous and ligamentous portions of the SIJ were analyzed. There was a significant positive correlation between the activity scores obtained by STIR and Gd-enhanced sequences (p < 0.0001). Agreement in the detection of bone marrow abnormalities occurred in 60 of the 80 joints, 35 with and 25 without signs of active disease. Discordance with STIR-positive marrow activity scores occurred in only 11 joints; Gd-enhanced positive scores in 9 joints. The STIR sequence detected remnants of marrow activity in the periphery of chronic fatty replacement not seen or partly obscured on the Gd sequence. Small subchondral enhancing lesions may not be scored on the STIR sequence, mostly because of reduced image resolution. Active bone marrow abnormalities were detected nearly equally well with STIR and Gd-enhanced fat-suppressed T1 sequences in patients with SpA, with STIR being most sensitive to visualize active abnormalities in the periphery of chronic changes.

  9. Microbleed and microinfarct detection in amyloid angiopathy: a high-resolution MRI-histopathology study

    PubMed Central

    van Veluw, Susanne J.; Charidimou, Andreas; van der Kouwe, Andre J.; Lauer, Arne; Reijmer, Yael D.; Costantino, Isabel; Gurol, M. Edip; Biessels, Geert Jan; Frosch, Matthew P.; Viswanathan, Anand; Greenberg, Steven M.

    2016-01-01

    Cerebral amyloid angiopathy is a common neuropathological finding in the ageing human brain, associated with cognitive impairment. Neuroimaging markers of severe cerebral amyloid angiopathy are cortical microbleeds and microinfarcts. These parenchymal brain lesions are considered key contributors to cognitive impairment. Therefore, they are important targets for therapeutic strategies and may serve as surrogate neuroimaging markers in clinical trials. We aimed to gain more insight into the pathological basis of magnetic resonance imaging-defined microbleeds and microinfarcts in cerebral amyloid angiopathy, and to explore the pathological burden that remains undetected, by using high and ultra-high resolution ex vivo magnetic resonance imaging, as well as detailed histological sampling. Brain samples from five cases (mean age 85 ± 6 years) with pathology-proven cerebral amyloid angiopathy and multiple microbleeds on in vivo clinical magnetic resonance imaging were subjected to high-resolution ex vivo 7 T magnetic resonance imaging. On the obtained high-resolution (200 μm isotropic voxels) ex vivo magnetic resonance images, 171 microbleeds were detected compared to 66 microbleeds on the corresponding in vivo magnetic resonance images. Of 13 sampled microbleeds that were matched on histology, five proved to be acute and eight old microhaemorrhages. The iron-positive old microhaemorrhages appeared approximately four times larger on magnetic resonance imaging compared to their size on histology. In addition, 48 microinfarcts were observed on ex vivo magnetic resonance imaging in three out of five cases (two cases exhibited no microinfarcts). None of them were visible on in vivo 1.5 T magnetic resonance imaging after a retrospective analysis. Of nine sampled microinfarcts that were matched on histology, five were confirmed as acute and four as old microinfarcts. Finally, we explored the proportion of microhaemorrhage and microinfarct burden that is beyond the detection limits of ex vivo magnetic resonance imaging, by scanning a smaller sample at ultra-high resolution, followed by serial sectioning. At ultra-high resolution (75 μm isotropic voxels) magnetic resonance imaging we observed an additional 48 microbleeds (compared to high resolution), which proved to correspond to vasculopathic changes (i.e. morphological changes to the small vessels) instead of frank haemorrhages on histology. After assessing the serial sections of this particular sample, no additional haemorrhages were observed that were missed on magnetic resonance imaging. In contrast, nine microinfarcts were found in these sections, of which six were only retrospectively visible at ultra-high resolution. In conclusion, these findings suggest that microbleeds on in vivo magnetic resonance imaging are specific for microhaemorrhages in cerebral amyloid angiopathy, and that increasing the resolution of magnetic resonance images results in the detection of more ‘non-haemorrhagic’ pathology. In contrast, the vast majority of microinfarcts currently remain under the detection limits of clinical in vivo magnetic resonance imaging. PMID:27645801

  10. Muscular MRI-based algorithm to differentiate inherited myopathies presenting with spinal rigidity.

    PubMed

    Tordjman, Mickael; Dabaj, Ivana; Laforet, Pascal; Felter, Adrien; Ferreiro, Ana; Biyoukar, Moustafa; Law-Ye, Bruno; Zanoteli, Edmar; Castiglioni, Claudia; Rendu, John; Beroud, Christophe; Chamouni, Alexandre; Richard, Pascale; Mompoint, Dominique; Quijano-Roy, Susana; Carlier, Robert-Yves

    2018-05-25

    Inherited myopathies are major causes of muscle atrophy and are often characterized by rigid spine syndrome, a clinical feature designating patients with early spinal contractures. We aim to present a decision algorithm based on muscular whole body magnetic resonance imaging (mWB-MRI) as a unique tool to orientate the diagnosis of each inherited myopathy long before the genetically confirmed diagnosis. This multicentre retrospective study enrolled 79 patients from referral centres in France, Brazil and Chile. The patients underwent 1.5-T or 3-T mWB-MRI. The protocol comprised STIR and T1 sequences in axial and coronal planes, from head to toe. All images were analyzed manually by multiple raters. Fatty muscle replacement was evaluated on mWB-MRI using both the Mercuri scale and statistical comparison based on the percentage of affected muscle. Between February 2005 and December 2015, 76 patients with genetically confirmed inherited myopathy were included. They were affected by Pompe disease or harbored mutations in RYR1, Collagen VI, LMNA, SEPN1, LAMA2 and MYH7 genes. Each myopathy had a specific pattern of affected muscles recognizable on mWB-MRI. This allowed us to create a novel decision algorithm for patients with rigid spine syndrome by segregating these signs. This algorithm was validated by five external evaluators on a cohort of seven patients with a diagnostic accuracy of 94.3% compared with the genetic diagnosis. We provide a novel decision algorithm based on muscle fat replacement graded on mWB-MRI that allows diagnosis and differentiation of inherited myopathies presenting with spinal rigidity. • Inherited myopathies are rare, diagnosis is challenging and genetic tests require specialized centres and often take years. • Inherited myopathies are often characterized by spinal rigidity. • Whole body magnetic resonance imaging is a unique tool to orientate the diagnosis of each inherited myopathy presenting with spinal rigidity. • Each inherited myopathy in this study has a specific pattern of affected muscles that orientate diagnosis. • A novel MRI-based algorithm, usable by every radiologist, can help the early diagnosis of these myopathies.

  11. Magnetic resonance imaging in neuropsychiatric systemic lupus erythematosus: current state of the art and novel approaches.

    PubMed

    Postal, M; Lapa, A Tamires; Reis, F; Rittner, L; Appenzeller, S

    2017-04-01

    Systemic lupus erythematosus is a chronic, inflammatory, immune-mediated disease affecting 0.1% of the general population. Neuropsychiatric manifestations in systemic lupus erythematosus have been more frequently recognized and reported in recent years, occurring in up to 75% of patients during the disease course. Magnetic resonance imaging is known to be a useful tool for the detection of structural brain abnormalities in neuropsychiatric systemic lupus erythematosus patients because of the excellent soft-tissue contrast observed with MRI and the ability to acquire multiplanar images. In addition to conventional magnetic resonance imaging techniques to evaluate the presence of atrophy and white matter lesions, several different magnetic resonance imaging techniques have been used to identify microstructural or functional abnormalities. This review will highlight different magnetic resonance imaging techniques, including the advanced magnetic resonance imaging methods used to determine central nervous system involvement in systemic lupus erythematosus.

  12. Correlation between Clinical Features and Magnetic Resonance Imaging Findings in Lumbar Disc Prolapse.

    PubMed

    Thapa, S S; Lakhey, R B; Sharma, P; Pokhrel, R K

    2016-05-01

    Magnetic resonance imaging is routinely done for diagnosis of lumbar disc prolapse. Many abnormalities of disc are observed even in asymptomatic patient.This study was conducted tocorrelate these abnormalities observed on Magnetic resonance imaging and clinical features of lumbar disc prolapse. A This prospective analytical study includes 57 cases of lumbar disc prolapse presenting to Department of Orthopedics, Tribhuvan University Teaching Hospital from March 2011 to August 2012. All patientshad Magnetic resonance imaging of lumbar spine and the findings regarding type, level and position of lumbar disc prolapse, any neural canal or foraminal compromise was recorded. These imaging findings were then correlated with clinical signs and symptoms. Chi-square test was used to find out p-value for correlation between clinical features and Magnetic resonance imaging findings using SPSS 17.0. This study included 57 patients, with mean age 36.8 years. Of them 41(71.9%) patients had radicular leg pain along specific dermatome. Magnetic resonance imaging showed 104 lumbar disc prolapselevel. Disc prolapse at L4-L5 and L5-S1 level constituted 85.5%.Magnetic resonance imaging findings of neural foramina compromise and nerve root compression were fairly correlated withclinical findings of radicular pain and neurological deficit. Clinical features and Magnetic resonance imaging findings of lumbar discprolasehad faircorrelation, but all imaging abnormalities do not have a clinical significance.

  13. MRI (Magnetic Resonance Imaging)

    MedlinePlus

    ... IV in the arm. MRI Research Programs at FDA Magnetic Resonance Imaging (MRI) Safety Electromagnetic Modeling Related ... Resonance Imaging Equipment in Clinical Use (March 2015) FDA/CDER: Information on Gadolinium-Based Contrast Agents Safety ...

  14. Detecting prostate cancer and prostatic calcifications using advanced magnetic resonance imaging

    PubMed Central

    Dou, Shewei; Bai, Yan; Shandil, Ankit; Ding, Degang; Shi, Dapeng; Haacke, E Mark; Wang, Meiyun

    2017-01-01

    Prostate cancer and prostatic calcifications have a high incidence in elderly men. We aimed to investigate the diagnostic capabilities of susceptibility-weighted imaging in detecting prostate cancer and prostatic calcifications. A total number of 156 men, including 34 with prostate cancer and 122 with benign prostate were enrolled in this study. Computed tomography, conventional magnetic resonance imaging, diffusion-weighted imaging, and susceptibility-weighted imaging were performed on all the patients. One hundred and twelve prostatic calcifications were detected in 87 patients. The sensitivities and specificities of the conventional magnetic resonance imaging, apparent diffusion coefficient, and susceptibility-filtered phase images in detecting prostate cancer and prostatic calcifications were calculated. McNemar's Chi-square test was used to compare the differences in sensitivities and specificities between the techniques. The results showed that the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic cancer were greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). In addition, the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic calcifications were comparable to that of computed tomography and greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). Given the high incidence of susceptibility-weighted imaging (SWI) abnormality in prostate cancer, we conclude that susceptibility-weighted imaging is more sensitive and specific than conventional magnetic resonance imaging, diffusion-weighted imaging, and computed tomography in detecting prostate cancer. Furthermore, susceptibility-weighted imaging can identify prostatic calcifications similar to computed tomography, and it is much better than conventional magnetic resonance imaging and diffusion-weighted imaging. PMID:27004542

  15. Detecting prostate cancer and prostatic calcifications using advanced magnetic resonance imaging.

    PubMed

    Dou, Shewei; Bai, Yan; Shandil, Ankit; Ding, Degang; Shi, Dapeng; Haacke, E Mark; Wang, Meiyun

    2017-01-01

    Prostate cancer and prostatic calcifications have a high incidence in elderly men. We aimed to investigate the diagnostic capabilities of susceptibility-weighted imaging in detecting prostate cancer and prostatic calcifications. A total number of 156 men, including 34 with prostate cancer and 122 with benign prostate were enrolled in this study. Computed tomography, conventional magnetic resonance imaging, diffusion-weighted imaging, and susceptibility-weighted imaging were performed on all the patients. One hundred and twelve prostatic calcifications were detected in 87 patients. The sensitivities and specificities of the conventional magnetic resonance imaging, apparent diffusion coefficient, and susceptibility-filtered phase images in detecting prostate cancer and prostatic calcifications were calculated. McNemar's Chi-square test was used to compare the differences in sensitivities and specificities between the techniques. The results showed that the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic cancer were greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). In addition, the sensitivity and specificity of susceptibility-filtered phase images in detecting prostatic calcifications were comparable to that of computed tomography and greater than that of conventional magnetic resonance imaging and apparent diffusion coefficient (P < 0.05). Given the high incidence of susceptibility-weighted imaging (SWI) abnormality in prostate cancer, we conclude that susceptibility-weighted imaging is more sensitive and specific than conventional magnetic resonance imaging, diffusion-weighted imaging, and computed tomography in detecting prostate cancer. Furthermore, susceptibility-weighted imaging can identify prostatic calcifications similar to computed tomography, and it is much better than conventional magnetic resonance imaging and diffusion-weighted imaging.

  16. Cardiac magnetic resonance imaging has limited additional yield in cryptogenic stroke evaluation after transesophageal echocardiography.

    PubMed

    Liberman, Ava L; Kalani, Rizwan E; Aw-Zoretic, Jessie; Sondag, Matthew; Daruwalla, Vistasp J; Mitter, Sumeet S; Bernstein, Richard; Collins, Jeremy D; Prabhakaran, Shyam

    2017-12-01

    Background The use of cardiac magnetic resonance imaging is increasing, but its role in the diagnostic work-up following ischemic stroke has received limited study. We aimed to explore the added yield of cardiac magnetic resonance imaging to identify cardio-aortic sources not detected by transesophageal echocardiography among patients with cryptogenic stroke. Methods A retrospective single-center cohort study was performed from 01 January 2009 to 01 March 2013. Consecutive patients who had both a stroke protocol cardiac magnetic resonance imaging and a transesophageal echocardiography preformed during a single hospitalization were included. All cardiac magnetic resonance imaging studies underwent independent, blinded review by two investigators. We applied the causative classification system for ischemic stroke to all patients, first blinded to cardiac magnetic resonance imaging results; we then reapplied the causative classification system using cardiac magnetic resonance imaging. Standard statistical tests to evaluate stroke subtype reclassification rates were used. Results Ninety-three patients were included in the final analysis; 68.8% were classified as cryptogenic stroke after initial diagnostic evaluation. Among patients with cryptogenic stroke, five (7.8%) were reclassified due to cardiac magnetic resonance imaging findings: one was reclassified as "cardio-aortic embolism evident" due to the presence of a patent foramen ovale and focal cardiac infarct and four were reclassified as "cardio-aortic embolism possible" due to mitral valve thickening (n = 1) or hypertensive cardiomyopathy (n = 3). Overall, findings on cardiac magnetic resonance imaging reduced the percentage of patients with cryptogenic stroke by slightly more than 1%. Conclusion Our stroke subtype reclassification rate after the addition of cardiac magnetic resonance imaging results to a diagnostic work-up which includes transesophageal echocardiography was very low. Prospective studies evaluating the role of cardiac magnetic resonance imaging and transesophageal echocardiography among patients with cryptogenic stroke should be considered.

  17. Consensus Recommendations of the Multiple Sclerosis Study Group and Portuguese Neuroradiological Society for the Use of the Magnetic Resonance Imaging in Multiple Sclerosis in Clinical Practice: Part 1.

    PubMed

    Abreu, Pedro; Pedrosa, Rui; Sá, Maria José; Cerqueira, João; Sousa, Lívia; Da Silva, Ana Martins; Pinheiro, Joaquim; De Sá, João; Batista, Sónia; Simões, Rita Moiron; Pereira, Daniela Jardim; Vilela, Pedro; Vale, José

    2018-05-30

    Magnetic resonance imaging is established as a recognizable tool in the diagnosis and monitoring of multiple sclerosis patients. In the present, among multiple sclerosis centers, there are different magnetic resonance imaging sequences and protocols used to study multiple sclerosis that may hamper the optimal use of magnetic resonance imaging in multiple sclerosis. In this context, the Group of Studies of Multiple Sclerosis and the Portuguese Society of Neuroradiology, after a joint discussion, appointed a committee of experts to create recommendations adapted to the national reality on the use of magnetic resonance imaging in multiple sclerosis. The purpose of this document is to publish the first Portuguese consensus recommendations on the use of magnetic resonance imaging in multiple sclerosis in clinical practice. The Group of Studies of Multiple Sclerosis and the Portuguese Society of Neuroradiology, after discussion of the topic in national meetings and after a working group meeting held in Figueira da Foz on May 2017, have appointed a committee of experts that have developed by consensus several standard protocols on the use of magnetic resonance imaging in the diagnosis and follow-up of multiple sclerosis. The document obtained was based on the best scientific evidence and expert opinion. Subsequently, the majority of Portuguese multiple sclerosis consultants and departments of neuroradiology scrutinized and reviewed the consensus paper; comments and suggestions were considered. Technical magnetic resonance imaging protocols regarding diagnostic, monitoring and the recommended information to be included in the magnetic resonance imaging report will be published in a separate paper. We provide some practical guidelines to promote standardized strategies to be applied in the clinical practice setting of Portuguese healthcare professionals regarding the use of magnetic resonance imaging in multiple sclerosis. We hope that these first Portuguese magnetic resonance imaging guidelines, based in the best available clinical evidence and practices, will serve to optimize multiple sclerosis management and improve multiple sclerosis patient care across Portugal.

  18. Role of PROPELLER-DWI of the prostate in reducing distortion and artefact from total hip replacement metalwork.

    PubMed

    Czarniecki, Marcin; Caglic, Iztok; Grist, James T; Gill, Andrew B; Lorenc, Kamil; Slough, Rhys A; Priest, Andrew N; Barrett, Tristan

    2018-05-01

    To compare image quality, artefact, and distortion in standard echo-planar imaging (EPI) with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for prostate magnetic resonance imaging (MRI) diffusion-weighted imaging (DWI) in patients with previous total hip replacement (THR). 21 male subjects with a clinical suspicion for, or known prostate cancer and previous THR were scanned at 1.5 T using a phased-array body coil. DWI was obtained using single-shot EPI and PROPELLER techniques using fat saturation (PROPELLER-DWI-FS), and without (PROPELLER-DWI-NFS). Image quality (the overall impression of diagnostic quality) was compared to T 2 -weighted (T2WI) imaging using a 5-point Likert scale, with diffusion sequences additionally scored for artefact and distortion according to a 4-point scale, with artefact defined as the amount of prostate affected and distortion as the degree of warping of the organ. The T2W and DW image volumes were compared to produce quantitative distortion maps. A two-sample Wilcoxon test compared the qualitative scores, with inter-reader variability calculated using Cohen's kappa. 21 patients were included in the study, with an average age of 70.4 years and PSA 9.2 ng/ml. Hip metalwork was present bilaterally in 3 patients, left-sided in 9, and right-sided in 9. PROPELLER-DWI-FS significantly improved image quality (p < 0.01) and reduced distortion (p < 0.01) when compared to standard EP-DWI. Artefact was not shown to be significantly improved. The last 5 patients in the study were additionally imaged with PROPELLER-DWI-NFS, which resulted in a significant reduction in artefact compared to EP-DWI (p < 0.05). Quantitative distortion was significantly lower compared to EP-DWI for both PROPELLER with fat saturation (p < 0.01) and without fat saturation (p < 0.01). PROPELLER-DWI demonstrates better image quality and decreases both artefact and distortion compared to conventional echo planar sequences in patients with hip metalwork. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm.

    PubMed

    Kwon, Ohin; Woo, Eung Je; Yoon, Jeong-Rock; Seo, Jin Keun

    2002-02-01

    We developed a new image reconstruction algorithm for magnetic resonance electrical impedance tomography (MREIT). MREIT is a new EIT imaging technique integrated into magnetic resonance imaging (MRI) system. Based on the assumption that internal current density distribution is obtained using magnetic resonance imaging (MRI) technique, the new image reconstruction algorithm called J-substitution algorithm produces cross-sectional static images of resistivity (or conductivity) distributions. Computer simulations show that the spatial resolution of resistivity image is comparable to that of MRI. MREIT provides accurate high-resolution cross-sectional resistivity images making resistivity values of various human tissues available for many biomedical applications.

  20. Noninvasive amide proton transfer magnetic resonance imaging in evaluating the grading and cellularity of gliomas.

    PubMed

    Bai, Yan; Lin, Yusong; Zhang, Wei; Kong, Lingfei; Wang, Lifu; Zuo, Panli; Vallines, Ignacio; Schmitt, Benjamin; Tian, Jie; Song, Xiaolei; Zhou, Jinyuan; Wang, Meiyun

    2017-01-24

    Using noninvasive magnetic resonance imaging techniques to accurately evaluate the grading and cellularity of gliomas is beneficial for improving the patient outcomes. Amide proton transfer imaging is a noninvasive molecular magnetic resonance imaging technique based on chemical exchange saturation transfer mechanism that detects endogenous mobile proteins and peptides in biological tissues. Between August 2012 and November 2015, a total number of 44 patients with pathologically proven gliomas were included in this study. We compared the capability of amide proton transfer magnetic resonance imaging with that of noninvasive diffusion-weighted imaging and noninvasive 3-dimensional pseudo-continuous arterial spin imaging in evaluating the grading and cellularity of gliomas. Our results reveal that amide proton transfer magnetic resonance imaging is a superior imaging technique to diffusion-weighted imaging and 3-dimensional pseudo-continuous arterial spin imaging in the grading of gliomas. In addition, our results showed that the Ki-67 index correlated better with the amide proton transfer-weighted signal intensity than with the apparent diffusion coefficient value or the cerebral blood flow value in the gliomas. Amide proton transfer magnetic resonance imaging is a promising method for predicting the grading and cellularity of gliomas.

  1. Magnetic Resonance Imaging (MRI): Lumbar Spine (For Parents)

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Lumbar Spine KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Lumbar Spine What's in this article? What ...

  2. Browsing software of the Visible Korean data used for teaching sectional anatomy.

    PubMed

    Shin, Dong Sun; Chung, Min Suk; Park, Hyo Seok; Park, Jin Seo; Hwang, Sung Bae

    2011-01-01

    The interpretation of computed tomographs (CTs) and magnetic resonance images (MRIs) to diagnose clinical conditions requires basic knowledge of sectional anatomy. Sectional anatomy has traditionally been taught using sectioned cadavers, atlases, and/or computer software. The computer software commonly used for this subject is practical and efficient for students but could be more advanced. The objective of this research was to present browsing software developed from the Visible Korean images that can be used for teaching sectional anatomy. One thousand seven hundred and two sets of MRIs, CTs, and sectioned images (intervals, one millimeter) of a whole male cadaver were prepared. Over 900 structures in the sectioned images were outlined and then filled with different colors to elaborate each structure. Software was developed where four corresponding images could be displayed simultaneously; in addition, the structures in the image data could be readily recognized with the aid of the color-filled outlines. The software, distributed free of charge, could be a valuable tool to teach medical students. For example, sectional anatomy could be taught by showing the sectioned images with real color and high resolution. Students could then review the lecture by using the sectioned and color-filled images on their own computers. Students could also be evaluated using the same software. Furthermore, other investigators would be able to replace the images for more comprehensive sectional anatomy. Copyright © 2011 Wiley-Liss, Inc.

  3. Diffusion tensor imaging of articular cartilage at 3T correlates with histology and biomechanics in a mechanical injury model.

    PubMed

    Ferizi, Uran; Rossi, Ignacio; Lee, Youjin; Lendhey, Matin; Teplensky, Jason; Kennedy, Oran D; Kirsch, Thorsten; Bencardino, Jenny; Raya, José G

    2017-07-01

    We establish a mechanical injury model for articular cartilage to assess the sensitivity of diffusion tensor imaging (DTI) in detecting cartilage damage early in time. Mechanical injury provides a more realistic model of cartilage degradation compared with commonly used enzymatic degradation. Nine cartilage-on-bone samples were obtained from patients undergoing knee replacement. The 3 Tesla DTI (0.18 × 0.18 × 1 mm 3 ) was performed before, 1 week, and 2 weeks after (zero, mild, and severe) injury, with a clinical radial spin-echo DTI (RAISED) sequence used in our hospital. We performed stress-relaxation tests and used a quasilinear-viscoelastic (QLV) model to characterize cartilage mechanical properties. Serial histology sections were dyed with Safranin-O and given an OARSI grade. We then correlated the changes in DTI parameters with the changes in QLV-parameters and OARSI grades. After severe injury the mean diffusivity increased after 1 and 2 weeks, whereas the fractional anisotropy decreased after 2 weeks (P < 0.05). The QLV-parameters and OARSI grades of the severe injury group differed from the baseline with statistical significance. The changes in mean diffusivity across all the samples correlated with the changes in the OARSI grade (r = 0.72) and QLV-parameters (r = -0.75). DTI is sensitive in tracking early changes after mechanical injury, and its changes correlate with changes in biomechanics and histology. Magn Reson Med 78:69-78, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. Image Guided Focal Therapy for Magnetic Resonance Imaging Visible Prostate Cancer: Defining a 3-Dimensional Treatment Margin Based on Magnetic Resonance Imaging Histology Co-Registration Analysis.

    PubMed

    Le Nobin, Julien; Rosenkrantz, Andrew B; Villers, Arnauld; Orczyk, Clément; Deng, Fang-Ming; Melamed, Jonathan; Mikheev, Artem; Rusinek, Henry; Taneja, Samir S

    2015-08-01

    We compared prostate tumor boundaries on magnetic resonance imaging and radical prostatectomy histological assessment using detailed software assisted co-registration to define an optimal treatment margin for achieving complete tumor destruction during image guided focal ablation. Included in study were 33 patients who underwent 3 Tesla magnetic resonance imaging before radical prostatectomy. A radiologist traced lesion borders on magnetic resonance imaging and assigned a suspicion score of 2 to 5. Three-dimensional reconstructions were created from high resolution digitalized slides of radical prostatectomy specimens and co-registered to imaging using advanced software. Tumors were compared between histology and imaging by the Hausdorff distance and stratified by the magnetic resonance imaging suspicion score, Gleason score and lesion diameter. Cylindrical volume estimates of treatment effects were used to define the optimal treatment margin. Three-dimensional software based registration with magnetic resonance imaging was done in 46 histologically confirmed cancers. Imaging underestimated tumor size with a maximal discrepancy between imaging and histological boundaries for a given tumor of an average ± SD of 1.99 ± 3.1 mm, representing 18.5% of the diameter on imaging. Boundary underestimation was larger for lesions with an imaging suspicion score 4 or greater (mean 3.49 ± 2.1 mm, p <0.001) and a Gleason score of 7 or greater (mean 2.48 ± 2.8 mm, p = 0.035). A simulated cylindrical treatment volume based on the imaging boundary missed an average 14.8% of tumor volume compared to that based on the histological boundary. A simulated treatment volume based on a 9 mm treatment margin achieved complete histological tumor destruction in 100% of patients. Magnetic resonance imaging underestimates histologically determined tumor boundaries, especially for lesions with a high imaging suspicion score and a high Gleason score. A 9 mm treatment margin around a lesion visible on magnetic resonance imaging would consistently ensure treatment of the entire histological tumor volume during focal ablative therapy. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Use of radiography, computed tomography and magnetic resonance imaging for evaluation of navicular syndrome in the horse.

    PubMed

    Widmer, W R; Buckwalter, K A; Fessler, J F; Hill, M A; VanSickle, D C; Ivancevich, S

    2000-01-01

    Radiographic evaluation of navicular syndrome is problematic because of its inconsistent correlation with clinical signs. Scintigraphy often yields false positive and false negative results and diagnostic ultrasound is of limited value. Therefore, we assessed the use of computed tomography and magnetic resonance imaging in a horse with clinical and radiographic signs of navicular syndrome. Cadaver specimens were examined with spiral computed tomographic and high-field magnetic resonance scanners and images were correlated with pathologic findings. Radiographic changes consisted of bony remodeling, which included altered synovial fossae, increased medullary opacity, cyst formation and shape change. These osseous changes were more striking and more numerous on computed tomographic and magnetic resonance images. They were most clearly defined with computed tomography. Many osseous changes seen with computed tomography and magnetic resonance imaging were not radiographically evident. Histologically confirmed soft tissue alterations of the deep digital flexor tendon, impar ligament and marrow were identified with magnetic resonance imaging, but not with conventional radiography. Because of their multiplanar capability and tomographic nature, computed tomography and magnetic resonance imaging surpass conventional radiography for navicular imaging, facilitating earlier, more accurate diagnosis. Current advances in imaging technology should make these imaging modalities available to equine practitioners in the future.

  6. Magnetic resonance imaging-directed transperineal limited-mapping prostatic biopsies to diagnose prostate cancer: a Scottish experience.

    PubMed

    Mukherjee, Ankur; Morton, Simon; Fraser, Sioban; Salmond, Jonathan; Baxter, Grant; Leung, Hing Y

    2014-11-01

    Transperineal prostatic biopsy is firmly established as an important tool in the diagnosis of prostate cancer. The benefit of additional imaging (magnetic resonance imaging) to target biopsy remains to be fully addressed. Using a cohort of consecutive patients undergoing transperineal template mapping biopsies, we studied positive biopsies in the context of magnetic resonance imaging findings and examined the accuracy of magnetic resonance imaging in predicting the location of transperineal template mapping biopsies-detected prostate cancer. Forty-four patients (mean age: 65 years, range 53-78) underwent transperineal template mapping biopsies. Thirty-four patients had 1-2 and 10 patients had ≥3 previous transrectal ultrasound scan-guided biopsies. The mean prostate-specific antigen was 15 ng/mL (range 2.5-79 ng/mL). High-grade prostatic intraepithelial neoplasia was found in 12 (27%) patients and prostate cancer with Gleason <7, 7 and >7 in 13, 10 and 8 patients, respectively. Suspicious lesions on magnetic resonance imaging scans were scored from 1 to 5. In 28 patients, magnetic resonance imaging detected lesions with score ≥3. Magnetic resonance imaging correctly localised transperineal template mapping biopsies-detected prostate cancer in a hemi-gland approach, particularly in a right to left manner (79% positive prediction rate), but not in a quadrant approach (33% positive prediction rate). Our findings support the notion of magnetic resonance imaging-based selection of patients for transperineal template mapping biopsies and that lesions revealed by magnetic resonance imaging are likely useful for targeted biopsies. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Sedation of Pediatric Patients in Magnetic Resonance Imaging

    DTIC Science & Technology

    2000-01-03

    f-U. 7. SEDATION OF PEDIATRIC PATIENTS IN MAGNETIC RESONANCE IMAGING Alesia D. Ricks APPROVED: ll^fll JohnJ>. McDonough,-CRNA, Ed.D., Chair...any copyrighted material in the thesis entitled: " Sedation of Pediatric Patients in Magnetic Resonance Imaging" beyond brief excerpts is with the...arise from such copyright violations. IV f SEDATION OF PEDIATRIC PATIENTS IN MAGNETIC RESONANCE IMAGING By CAPT ALESIA D. RICKS, RN, BSN, NQUSAF

  8. Using 3 Tesla magnetic resonance imaging in the pre-operative evaluation of tongue carcinoma.

    PubMed

    Moreno, K F; Cornelius, R S; Lucas, F V; Meinzen-Derr, J; Patil, Y J

    2017-09-01

    This study aimed to evaluate the role of 3 Tesla magnetic resonance imaging in predicting tongue tumour thickness via direct and reconstructed measures, and their correlations with corresponding histological measures, nodal metastasis and extracapsular spread. A prospective study was conducted of 25 patients with histologically proven squamous cell carcinoma of the tongue and pre-operative 3 Tesla magnetic resonance imaging from 2009 to 2012. Correlations between 3 Tesla magnetic resonance imaging and histological measures of tongue tumour thickness were assessed using the Pearson correlation coefficient: r values were 0.84 (p < 0.0001) and 0.81 (p < 0.0001) for direct and reconstructed measurements, respectively. For magnetic resonance imaging, direct measures of tumour thickness (mean ± standard deviation, 18.2 ± 7.3 mm) did not significantly differ from the reconstructed measures (mean ± standard deviation, 17.9 ± 7.2 mm; r = 0.879). Moreover, 3 Tesla magnetic resonance imaging had 83 per cent sensitivity, 82 per cent specificity, 82 per cent accuracy and a 90 per cent negative predictive value for detecting cervical lymph node metastasis. In this cohort, 3 Tesla magnetic resonance imaging measures of tumour thickness correlated highly with the corresponding histological measures. Further, 3 Tesla magnetic resonance imaging was an effective method of detecting malignant adenopathy with extracapsular spread.

  9. The predictive value of magnetic resonance imaging of retinoblastoma for the likelihood of high-risk pathologic features.

    PubMed

    Hiasat, Jamila G; Saleh, Alaa; Al-Hussaini, Maysa; Al Nawaiseh, Ibrahim; Mehyar, Mustafa; Qandeel, Monther; Mohammad, Mona; Deebajah, Rasha; Sultan, Iyad; Jaradat, Imad; Mansour, Asem; Yousef, Yacoub A

    2018-06-01

    To evaluate the predictive value of magnetic resonance imaging in retinoblastoma for the likelihood of high-risk pathologic features. A retrospective study of 64 eyes enucleated from 60 retinoblastoma patients. Contrast-enhanced magnetic resonance imaging was performed before enucleation. Main outcome measures included demographics, laterality, accuracy, sensitivity, and specificity of magnetic resonance imaging in detecting high-risk pathologic features. Optic nerve invasion and choroidal invasion were seen microscopically in 34 (53%) and 28 (44%) eyes, respectively, while they were detected in magnetic resonance imaging in 22 (34%) and 15 (23%) eyes, respectively. The accuracy of magnetic resonance imaging in detecting prelaminar invasion was 77% (sensitivity 89%, specificity 98%), 56% for laminar invasion (sensitivity 27%, specificity 94%), 84% for postlaminar invasion (sensitivity 42%, specificity 98%), and 100% for optic cut edge invasion (sensitivity100%, specificity 100%). The accuracy of magnetic resonance imaging in detecting focal choroidal invasion was 48% (sensitivity 33%, specificity 97%), and 84% for massive choroidal invasion (sensitivity 53%, specificity 98%), and the accuracy in detecting extrascleral extension was 96% (sensitivity 67%, specificity 98%). Magnetic resonance imaging should not be the only method to stratify patients at high risk from those who are not, eventhough it can predict with high accuracy extensive postlaminar optic nerve invasion, massive choroidal invasion, and extrascleral tumor extension.

  10. Functional Magnetic Resonance Imaging and Spectroscopic Imaging of the Brain: Application of fMRI and fMRS to Reading Disabilities and Education.

    ERIC Educational Resources Information Center

    Richards, Todd L.

    2001-01-01

    This tutorial/review covers functional brain-imaging methods and results used to study language and reading disabilities. Although the emphasis is on magnetic resonance imaging and functional magnetic resonance spectroscopy, other imaging techniques are also discussed including positron emission tomography, electroencephalography,…

  11. EPR Imaging at a Few Megahertz Using SQUID Detectors

    NASA Technical Reports Server (NTRS)

    Hahn, Inseob; Day, Peter; Penanen, Konstantin; Eom, Byeong Ho

    2010-01-01

    An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

  12. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging.

    PubMed

    Itsukage, Shizu; Sowa, Yoshihiro; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.

  13. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging

    PubMed Central

    Itsukage, Shizu; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes’ principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging. PMID:29308107

  14. Clinical Evaluation and Magnetic Resonance Imaging Assessment of Intradiscal Methylene Blue Injection for the Treatment of Discogenic Low Back Pain.

    PubMed

    Zhang, XiaoJun; Hao, Jie; Hu, Zhenming; Yang, HaiTao

    2016-01-01

    Low back pain is a common worldwide health problem and has a significant socioeconomic impact on public health. Internal disc disruption has been considered as the most common cause of low back pain. Various therapies, including interbody fusion, disc replacement, injection therapies, and thermal annular procedures have been utilized for the treatment of discogenic low back pain. Recently, a new method of intradiscal methylene blue injection has been introduced to treat discogenic low back pain, but the clinical outcomes are controversial. To investigate the clinical outcomes and magnetic resonance imaging changes of intradiscal methylene blue injection for the treatment of discogenic low back pain. Observational study. An interventional low back pain management practice in a university hospital. A total of 33 patients were selected to be treated with intradiscal methylene blue injection. The clinical outcomes were evaluated by numeric rating scale and Oswestry Disability Index at pretreatment, one month, 3, 6, and 12 months after treatment. The magnetic resonance imaging changes of involved intervertebral discs were assessed by apparent diffusion coefficient and T2 values at pretreatment, 3, 6, and 12 months after treatment. All of the patients got a follow-up period up to 12 months. The mean numeric rating scale scores at pretreatment, one month, 3, 6, and 12 months after treatment were 6.54, 2.98, 3.23, 3.66, and 4.72, respectively. There was a minimum of 2 points reduction at one month, 3, and 6 months after treatment, but less than 2 points reduction at 12 months. There was at least 50% improvement on the Oswestry Disability Index at one month, 3, and 6 months after treatment, but not at 12 months. The mean apparent diffusion coefficient and T2 value were significantly higher at 6 and12 months after treatment compared to pretreatment, but there was no significant difference between pretreatment and 3 months after treatment. This is an observational study with a relatively small sample size and short-term follow-up. The intradiscal methylene blue injection might be an effective therapy for discogenic low back pain for the short-term and could improve disc degeneration condition to some extent.Key words: Low back pain, discogenic pain, internal disc disruption, provocation discography, methylene blue, intradiscal injection, disc degeneration, magnetic resonance, imaging.

  15. Magnetic Resonance Imaging (MRI) Safety

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how does ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining detailed ...

  16. Biomedical Imaging in Implantable Drug Delivery Systems

    PubMed Central

    Zhou, Haoyan; Hernandez, Christopher; Goss, Monika; Gawlik, Anna; Exner, Agata A.

    2015-01-01

    Implantable drug delivery systems (DDS) provide a platform for sustained release of therapeutic agents over a period of weeks to months and sometimes years. Such strategies are typically used clinically to increase patient compliance by replacing frequent administration of drugs such as contraceptives and hormones to maintain plasma concentration within the therapeutic window. Implantable or injectable systems have also been investigated as a means of local drug administration which favors high drug concentration at a site of interest, such as a tumor, while reducing systemic drug exposure to minimize unwanted side effects. Significant advances in the field of local DDS have led to increasingly sophisticated technology with new challenges including quantification of local and systemic pharmacokinetics and implant-body interactions. Because many of these sought-after parameters are highly dependent on the tissue properties at the implantation site, and rarely represented adequately with in vitro models, new nondestructive techniques that can be used to study implants in situ are highly desirable. Versatile imaging tools can meet this need and provide quantitative data on morphological and functional aspects of implantable systems. The focus of this review article is an overview of current biomedical imaging techniques, including magnetic resonance imaging (MRI), ultrasound imaging, optical imaging, X-ray and computed tomography (CT), and their application in evaluation of implantable DDS. PMID:25418857

  17. Clinical Benefit of 3 Tesla Magnetic Resonance Imaging Rescanning in Patients With Focal Epilepsy and Negative 1.5 Tesla Magnetic Resonance Imaging.

    PubMed

    Ladino, Lady D; Balaguera, Pedro; Rascovsky, Simon; Delgado, Jorge; Llano, Juan; Hernández-Ronquillo, Lizbeth; Gómez-Arias, Bety; Téllez-Zenteno, José F

    2016-01-01

    Magnetic resonance imaging is an essential tool in the pre-surgical evaluation of patients with drug-resistant epilepsy. Our aim was to assess the value of re-imaging patients with focal drug-resistant epilepsy. Thirty patients with negative or non-conclusive 1.5 Tesla magnetic resonance imaging were rescanned with 1.5T and 3T. All of them had previous 1.5 scans with no seizure protocol in a non-specialized center. Two neuroradiologists who were blinded to prior imaging results randomly reviewed the magnetic resonance images. Kappa score was used to assess the reliability. Mean age of patients was 30 (SD ± 11) years. The intra-observer agreement for the first radiologist was 0.74 for 1.5T and 0.71 for 3T. In the second radiologist it was 0.82 and 0.66, respectively. Three lesions (10%) were identified by general radiologists in non-specialized centers using a 1.5T standard protocol. In our center a consensus between two neuroradiologists using epilepsy protocol identified seven lesions (23%) using 1.5T and 10 (33%) using 3T (p < 0.01). In 28% of patients this additional information resulted in a change in clinical management. 3T magnetic resonance imaging rescanning improves the diagnostic yield in patients with focal epilepsy and previous negative 1.5T magnetic resonance imaging. Use of 3T magnetic resonance imaging, epilepsy protocols, and interpretation by experienced neuroradiologists is highly recommended.

  18. The performance of magnetic resonance imaging in the detection of triangular fibrocartilage complex injury: a meta-analysis.

    PubMed

    Wang, Z X; Chen, S L; Wang, Q Q; Liu, B; Zhu, J; Shen, J

    2015-06-01

    The aim of this study was to evaluate the accuracy of magnetic resonance imaging in the detection of triangular fibrocartilage complex injury through a meta-analysis. A comprehensive literature search was conducted before 1 April 2014. All studies comparing magnetic resonance imaging results with arthroscopy or open surgery findings were reviewed, and 25 studies that satisfied the eligibility criteria were included. Data were pooled to yield pooled sensitivity and specificity, which were respectively 0.83 and 0.82. In detection of central and peripheral tears, magnetic resonance imaging had respectively a pooled sensitivity of 0.90 and 0.88 and a pooled specificity of 0.97 and 0.97. Six high-quality studies using Ringler's recommended magnetic resonance imaging parameters were selected for analysis to determine whether optimal imaging protocols yielded better results. The pooled sensitivity and specificity of these six studies were 0.92 and 0.82, respectively. The overall accuracy of magnetic resonance imaging was acceptable. For peripheral tears, the pooled data showed a relatively high accuracy. Magnetic resonance imaging with appropriate parameters are an ideal method for diagnosing different types of triangular fibrocartilage complex tears. © The Author(s) 2015.

  19. Super-contrast photoacoustic resonance imaging

    NASA Astrophysics Data System (ADS)

    Gao, Fei; Zhang, Ruochong; Feng, Xiaohua; Liu, Siyu; Zheng, Yuanjin

    2018-02-01

    In this paper, a new imaging modality, named photoacoustic resonance imaging (PARI), is proposed and experimentally demonstrated. Being distinct from conventional single nanosecond laser pulse induced wideband PA signal, the proposed PARI method utilizes multi-burst modulated laser source to induce PA resonant signal with enhanced signal strength and narrower bandwidth. Moreover, imaging contrast could be clearly improved than conventional single-pulse laser based PA imaging by selecting optimum modulation frequency of the laser source, which originates from physical properties of different materials beyond the optical absorption coefficient. Specifically, the imaging steps is as follows: 1: Perform conventional PA imaging by modulating the laser source as a short pulse to identify the location of the target and the background. 2: Shine modulated laser beam on the background and target respectively to characterize their individual resonance frequency by sweeping the modulation frequency of the CW laser source. 3: Select the resonance frequency of the target as the modulation frequency of the laser source, perform imaging and get the first PARI image. Then choose the resonance frequency of the background as the modulation frequency of the laser source, perform imaging and get the second PARI image. 4: subtract the first PARI image from the second PARI image, then we get the contrast-enhanced PARI results over the conventional PA imaging in step 1. Experimental validation on phantoms have been performed to show the merits of the proposed PARI method with much improved image contrast.

  20. Assessment of Hemodynamic Conditions in the Aorta Following Root Replacement with Composite Valve-Conduit Graft.

    PubMed

    Cheng, Zhuo; Kidher, Emaddin; Jarral, Omar A; O'Regan, Declan P; Wood, Nigel B; Athanasiou, Thanos; Xu, Xiao Yun

    2016-05-01

    This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced.

  1. Replacing missing data between airborne SAR coherent image pairs

    DOE PAGES

    Musgrove, Cameron H.; West, James C.

    2017-07-31

    For synthetic aperture radar systems, missing data samples can cause severe image distortion. When multiple, coherent data collections exist and the missing data samples do not overlap between collections, there exists the possibility of replacing data samples between collections. For airborne radar, the known and unknown motion of the aircraft prevents direct data sample replacement to repair image features. Finally, this paper presents a method to calculate the necessary phase corrections to enable data sample replacement using only the collected radar data.

  2. Replacing missing data between airborne SAR coherent image pairs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musgrove, Cameron H.; West, James C.

    For synthetic aperture radar systems, missing data samples can cause severe image distortion. When multiple, coherent data collections exist and the missing data samples do not overlap between collections, there exists the possibility of replacing data samples between collections. For airborne radar, the known and unknown motion of the aircraft prevents direct data sample replacement to repair image features. Finally, this paper presents a method to calculate the necessary phase corrections to enable data sample replacement using only the collected radar data.

  3. Power loss and right ventricular efficiency in patients after tetralogy of Fallot repair with pulmonary insufficiency: clinical implications.

    PubMed

    Fogel, Mark A; Sundareswaran, Kartik S; de Zelicourt, Diane; Dasi, Lakshmi P; Pawlowski, Tom; Rome, Jack; Yoganathan, Ajit P

    2012-06-01

    To quantify right ventricular output power and efficiency and correlate these to ventricular function in patients with repaired tetralogy of Fallot. This might aid in determining the optimal timing for pulmonary valve replacement. We reviewed the cardiac catheterization and magnetic resonance imaging data of 13 patients with tetralogy of Fallot (age, 22 ± 17 years). Using pressure and flow measurements in the main pulmonary artery, cardiac output and regurgitation fraction, right ventricular (RV) power output, loss, and efficiency were calculated. The RV function was evaluated using cardiac magnetic resonance imaging. The RV systolic power was 1.08 ± 0.62 W, with 20.3% ± 8.6% power loss owing to 41% ± 14% pulmonary regurgitation (efficiency, 79.7% ± 8.6%; 0.84 ± 0.73 W), resulting in a net cardiac output of 4.24 ± 1.82 L/min. Power loss correlated significantly with the indexed RV end-diastolic and end-systolic volume (R = 0.78, P = .002 and R = 0.69, P = .009, respectively). The normalized RV power output had a significant negative correlation with RV end-diastolic and end-systolic volumes (both R = -0.87, P = .002 and R = -0.68, P = .023, respectively). A rapid decrease occurred in the RV power capacity with an increasing RV volume, with the curve flattening out at an indexed RV end-diastolic and end-systolic volume threshold of 139 mL/m(2) and 75 mL/m(2), respectively. Significant power loss is present in patients with repaired tetralogy of Fallot and pulmonary regurgitation. A rapid decrease in efficiency occurs with increasing RV volume, suggesting that pulmonary valve replacement should be done before the critical value of 139 mL/m(2) and 75 mL/m(2) for the RV end-diastolic and end-systolic volume, respectively, to preserve RV function. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  4. Postoperative Reverse Remodeling and Symptomatic Improvement in Normal-Flow Low-Gradient Aortic Stenosis After Aortic Valve Replacement.

    PubMed

    Carter-Storch, Rasmus; Møller, Jacob E; Christensen, Nicolaj L; Irmukhadenov, Akhmadjon; Rasmussen, Lars M; Pecini, Redi; Øvrehus, Kristian A; Søndergård, Eva V; Marcussen, Niels; Dahl, Jordi S

    2017-12-01

    Severe aortic stenosis (AS) most often presents with reduced aortic valve area (<1 cm 2 ), normal stroke volume index (≥35 mL/m 2 ), and either high mean gradient (≥40 mm Hg; normal-flow high-gradient AS) or low mean gradient (normal-flow low-gradient [NFLG] AS). The benefit of aortic valve replacement (AVR) among NFLG patients is controversial. We compared the impact of NFLG condition on preoperative left ventricular (LV) remodeling and myocardial fibrosis and postoperative remodeling and symptomatic benefit. Eighty-seven consecutive patients with reduced aortic valve area and normal stroke volume index undergoing AVR underwent echocardiography, magnetic resonance imaging, a 6-minute walk test, and measurement of natriuretic peptides before and 1 year after AVR. Myocardial fibrosis was assessed from magnetic resonance imaging. Patients were stratified as NFLG or normal-flow high-gradient. In total, 33 patients (38%) had NFLG. Before AVR, they were characterized by similar symptom burden but less severe AS measured by aortic valve area index (0.50±0.09 versus 0.40±0.08 cm 2 /m 2 ; P <0.0001), lower LV mass index (74±18 versus 90±26 g/m 2 ; P =0.01), but the same degree of myocardial fibrosis. After AVR, NFLG had a smaller reduction in LV mass index (-3±10 versus -±18 g/m 2 ; P <0.0001) and a smaller reduction in natriuretic peptides. Both groups experienced similar symptomatic improvement. Normal-flow high-gradient condition independently predicted change in LV mass index. Patients with NFLG had less severe AS and LV remodeling than patients with normal-flow high-gradient. Furthermore, NFLG patients experienced less reverse remodeling but the same symptomatic benefit. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02316587. © 2017 American Heart Association, Inc.

  5. An Improved Prism for Use in Laser Resonators

    DTIC Science & Technology

    1981-08-01

    reflection (TIR) prisms , will be shown to give significant advantages over the use of Porro prisms when used in polarisation coupled laser resonators . 2... resonator as shown in figure 2. As in the case of the crossed- Porro laser an in-line or folded configuration can be used. The compound TIR prism at the...thrashold, etc, rather than on refractive index, as in the case of Porro prisms . In conventional Q-switched Nd:YAG resonators , replacement of the 100

  6. The Choice of a Laser for Airborne Depth Sounding

    DTIC Science & Technology

    1981-09-01

    cavity, polariser, Pockels cell and have the same resonator length,. The Porro prisms of the PCCP are replaced by mirrors in the conventional...crossed Porro resonator The operation of this resonator is described in references 6 and 7. It contains two Porro prisms , one at each end of the...p968, March 1980 "Laser Resonator : An Electrooptically Q-Switched Porro Prism Device" Applied Optics, 15, 8, pl942, August 1976 10 11 See, B.A

  7. Magnetic resonance imaging screening results compared with explantation results in poly implant prothèse silicone breast implants, recalled from the European market in 2010.

    PubMed

    Maijers, Maria C; Niessen, Francisus B; Veldhuizen, Jacob F H; Ritt, Marco J P F; Manoliu, Radu A

    2014-02-01

    In a prospective cohort study, the authors followed 112 women whose Poly Implant Prothèse silicone breast implants were recalled. Magnetic resonance imaging results and clinical consequences were previously published. The authors compared magnetic resonance imaging screening with explantation results to study the diagnostic value of magnetic resonance imaging in this unique unselected and nonbiased group. women with 224 proven Poly Implant Prothèse implants after a mean implantation time of 10 years were enrolled in 2011. All women underwent magnetic resonance imaging screening and were offered explantation. The explantation details of 107 women could be compared with magnetic resonance imaging results. Of 107 women, 29 (27 percent) had at least one ruptured implant at explantation, and 44 of 214 explanted implants (21 percent) were ruptured. The magnetic resonance imaging results correctly diagnosed 154 intact and 35 ruptured implants. Sensitivity and specificity were 80 percent and 91 percent, respectively. The positive predictive value was 69 percent, and the negative predictive value was 95 percent. The accuracy of magnetic resonance imaging is comparable to previously published data from other manufacturers of modern silicone implants but lower than that of some recent validation studies in selected symptomatic women. The authors believe that this study is representative of common daily practice as they followed normal day-to-day magnetic resonance imaging protocol without using multiple independent readers. The authors hope that this study will contribute to the ongoing discussion to screen asymptomatic women with modern silicone breast implants. Diagnostic, II.

  8. Magnetic resonance imaging tractography as a diagnostic tool in patients with spinal cord injury treated with human embryonic stem cells.

    PubMed

    Shroff, Geeta

    2017-02-01

    Introduction Spinal cord injury is a cause of severe disability and mortality. The pharmacological and non-pharmacological methods used, are unable to improve the quality of life in spinal cord injury. Spinal disorders have been treated with human embryonic stem cells. Magnetic resonance imaging and tractography were used as imaging modality to document the changes in the damaged cord, but the magnetic resonance imaging tractography was seen to be more sensitive in detecting the changes in the spinal cord. The present study was conducted to evaluate the diagnostic modality of magnetic resonance imaging tractography to determine the efficacy of human embryonic stem cells in chronic spinal cord injury. Materials and methods The study included the patients with spinal cord injury for whom magnetic resonance imaging tractography was performed before and after the therapy. Omniscan (gadodiamide) magnetic resonance imaging tractography was analyzed to assess the spinal defects and the improvement by human embryonic stem cell treatment. The patients were also scored by American Spinal Injury Association scale. Results Overall, 15 patients aged 15-44 years with clinical manifestations of spinal cord injury had magnetic resonance imaging tractography performed. The average treatment period was nine months. The majority of subjects ( n = 13) had American Spinal Injury Association score A, and two patients were at score C at the beginning of therapy. At the end of therapy, 10 patients were at score A, two patients were at score B and three patients were at score C. Improvements in patients were clearly understood through magnetic resonance imaging tractography as well as in clinical signs and symptoms. Conclusion Magnetic resonance imaging tractography can be a crucial diagnostic modality to assess the improvement in spinal cord injury patients.

  9. Symptomatic adjacent segment disease after cervical total disc replacement: re-examining the clinical and radiological evidence with established criteria.

    PubMed

    Nunley, Pierce D; Jawahar, Ajay; Cavanaugh, David A; Gordon, Charles R; Kerr, Eubulus J; Utter, Phillip Andrew

    2013-01-01

    Although several publications in the last decade have proved equality in safety and efficacy of the total disc replacement (TDR) to the anterior fusion procedure in cervical spine, the claim that TDR may reduce the incidence of adjacent segment disease (ASD) has not been corroborated by clinical evidence. We attempt to predict the true incidence of symptomatic ASD after TDR surgery in the cervical spine at one or two levels at a median follow-up period of 4 years. A total of 763 patients were screened to participate in four different Food and Drug Administration device exemption trials for artificial cervical disc replacement at three collaborating institutions. Two hundred seventy-one patients qualified and enrolled in the trials. One hundred seventy-three randomized to receive artificial disc replacement surgery, and 167 have completed a 4-year or longer follow-up. Patients experiencing cervical radiculopathy symptoms in the follow-up period were worked-up with clinical examinations, magnetic resonance imaging of the cervical spine, and other diagnostic studies. Once a clinical correlation was established with the imaging evidence of adjacent segment degeneration, a careful record was maintained to document the subsequent medical and/or surgical treatment received by these patients. Statistical analysis was performed to determine the true incidence of and factors affecting the ASD after cervical disc replacement in these patients. Twenty-six patients (15.2%) were identified to satisfy our criteria for ASD at the median follow-up of 51 months, with the annual incidence of 3.1% as calculated by life tables. The actuarial 5-year freedom from ASD rate was 71.6%±0.6%, and the mean period for freedom from ASD was 70.4±2.1 months. The incidence of symptomatic ASD after cervical TDR is 3.1% annually regardless of the patient's age, sex, smoking habits, and design of the TDR device. The presence of osteopenia and lumbar degenerative disease significantly increase the risk of developing ASD after anterior cervical surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Comparing Magnetic Resonance Imaging and High-Resolution Dynamic Ultrasonography for Diagnosis of Plantar Plate Pathology: A Case Series.

    PubMed

    Donegan, Ryan J; Stauffer, Anthony; Heaslet, Michael; Poliskie, Michael

    Plantar plate pathology has gained noticeable attention in recent years as an etiology of lesser metatarsophalangeal joint pain. The heightened clinical awareness has led to the need for more effective diagnostic imaging accuracy. Numerous reports have established the accuracy of both magnetic resonance imaging and ultrasonography for the diagnosis of plantar plate pathology. However, no conclusions have been made regarding which is the superior imaging modality. The present study reports a case series directly comparing high-resolution dynamic ultrasonography and magnetic resonance imaging. A multicenter retrospective comparison of magnetic resonance imaging versus high-resolution dynamic ultrasonography to evaluate plantar plate pathology with surgical confirmation was conducted. The sensitivity, specificity, and positive and negative predictive values for magnetic resonance imaging were 60%, 100%, 100%, and 33%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 66%. The sensitivity, specificity, and positive and negative predictive values for high-resolution dynamic ultrasound imaging were 100%, 100%, 100%, and 100%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 100%. The p value using Fisher's exact test for magnetic resonance imaging and high-resolution dynamic ultrasonography was p = .45, a difference that was not statistically significant. High-resolution dynamic ultrasonography had greater accuracy than magnetic resonance imaging in diagnosing lesser metatarsophalangeal joint plantar plate pathology, although the difference was not statistically significant. The present case series suggests that high-resolution dynamic ultrasonography can be considered an equally accurate imaging modality for plantar plate pathology at a potential cost savings compared with magnetic resonance imaging. Therefore, high-resolution dynamic ultrasonography warrants further investigation in a prospective study. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Improvement of 19F MR image uniformity in a mouse model of cellular therapy using inductive coupling.

    PubMed

    Park, Bu S; Ma, Ge; Koch, William T; Rajan, Sunder S; Mastromanolis, Manuel; Lam, Johnny; Sung, Kyung; McCright, Brent

    2018-06-15

    Improve 19 F magnetic resonance imaging uniformity of perfluorocarbon (PFC)-labeled cells by using a secondary inductive resonator tuned to 287 MHz to enhance the induced radio frequency (RF) magnetic field (B 1 ) at 7.05 T. Following Faraday's induction law, the sign of induced B 1 made by the secondary resonator can be changed depending on the tuning of the resonator. A secondary resonator located on the opposite side of the phantom of the 19 F surface coil can be shown to enhance or subtract the induced B 1 field, depending upon its tuning. The numerical simulation results of rotating transmit B 1 magnitude (|B 1 + |) and corresponding experimental 19 F images were compared without and with the secondary resonator. With the secondary resonator tuned to 287 MHz, improvements of |B 1 + | and 19 F image uniformity were demonstrated. The use of the secondary resonator improved our ability to visualize transplanted cell location non-invasively over a period of 6 weeks. The secondary resonator tuned to enhance the induced B 1 results in improved image uniformity in a pre-clinical application, enabling cell tracking of PFC-labeled cells with the secondary resonator.

  12. Fiducial-based fusion of 3D dental models with magnetic resonance imaging.

    PubMed

    Abdi, Amir H; Hannam, Alan G; Fels, Sidney

    2018-04-16

    Magnetic resonance imaging (MRI) is widely used in study of maxillofacial structures. While MRI is the modality of choice for soft tissues, it fails to capture hard tissues such as bone and teeth. Virtual dental models, acquired by optical 3D scanners, are becoming more accessible for dental practice and are starting to replace the conventional dental impressions. The goal of this research is to fuse the high-resolution 3D dental models with MRI to enhance the value of imaging for applications where detailed analysis of maxillofacial structures are needed such as patient examination, surgical planning, and modeling. A subject-specific dental attachment was digitally designed and 3D printed based on the subject's face width and dental anatomy. The attachment contained 19 semi-ellipsoidal concavities in predetermined positions where oil-based ellipsoidal fiducial markers were later placed. The MRI was acquired while the subject bit on the dental attachment. The spatial position of the center of mass of each fiducial in the resultant MR Image was calculated by averaging its voxels' spatial coordinates. The rigid transformation to fuse dental models to MRI was calculated based on the least squares mapping of corresponding fiducials and solved via singular-value decomposition. The target registration error (TRE) of the proposed fusion process, calculated in a leave-one-fiducial-out fashion, was estimated at 0.49 mm. The results suggest that 6-9 fiducials suffice to achieve a TRE of equal to half the MRI voxel size. Ellipsoidal oil-based fiducials produce distinguishable intensities in MRI and can be used as registration fiducials. The achieved accuracy of the proposed approach is sufficient to leverage the merged 3D dental models with the MRI data for a finer analysis of the maxillofacial structures where complete geometry models are needed.

  13. Magnetically engineered Cd-free quantum dots as dual-modality probes for fluorescence/magnetic resonance imaging of tumors.

    PubMed

    Ding, Ke; Jing, Lihong; Liu, Chunyan; Hou, Yi; Gao, Mingyuan

    2014-02-01

    Magnetically engineered Cd-free CuInS2@ZnS:Mn quantum dots (QDs) were designed, synthesized, and evaluated as potential dual-modality probes for fluorescence and magnetic resonance imaging (MRI) of tumors in vivo. The synthesis of Mn-doped core-shell structured CuInS2@ZnS mainly comprised three steps, i.e., the preparation of fluorescent CuInS2 seeds, the particle surface coating of ZnS, and the Mn-doping of the ZnS shells. Systematic spectroscopy studies were carried out to illustrate the impacts of ZnS coating and the following Mn-doping on the optical properties of the QDs. In combination with conventional fluorescence, fluorescence excitation, and time-resolved fluorescence measurements, the structure of CuInS2@ZnS:Mn QDs prepared under optimized conditions presented a Zn gradient CuInS2 core and a ZnS outer shell, while Mn ions were mainly located in the ZnS shell, which well balanced the optical and magnetic properties of the resultant QDs. For the following in vivo imaging experiments, the hydrophobic CuInS2@ZnS:Mn QDs were transferred into water upon ligand exchange reactions by replacing the 1-dodecanethiol ligand with dihydrolipoic acid-poly(ethylene glycol) (DHLA-PEG) ligand. The MTT assays based on HeLa cells were carried out to evaluate the cytotoxicity of the current Cd-free CuInS2@ZnS:Mn QDs for comparing with that of water soluble CdTe QDs. Further in vivo fluorescence and MR imaging experiments suggested that the PEGylated CuInS2@ZnS:Mn QDs could well target both subcutaneous and intraperitoneal tumors in vivo. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Investigation of lithium distribution in the rat brain ex vivo using lithium-7 magnetic resonance spectroscopy and imaging at 17.2 T.

    PubMed

    Stout, Jacques; Hanak, Anne-Sophie; Chevillard, Lucie; Djemaï, Boucif; Risède, Patricia; Giacomini, Eric; Poupon, Joël; Barrière, David André; Bellivier, Frank; Mégarbane, Bruno; Boumezbeur, Fawzi

    2017-11-01

    Lithium is the first-line mood stabilizer for the treatment of patients with bipolar disorder. However, its mechanisms of action and transport across the blood-brain barrier remain poorly understood. The contribution of lithium-7 magnetic resonance imaging ( 7 Li MRI) to investigate brain lithium distribution remains limited because of the modest sensitivity of the lithium nucleus and the expected low brain concentrations in humans and animal models. Therefore, we decided to image lithium distribution in the rat brain ex vivo using a turbo-spin-echo imaging sequence at 17.2 T. The estimation of lithium concentrations was performed using a phantom replacement approach accounting for B 1 inhomogeneities and differential T 1 and T 2 weighting. Our MRI-derived lithium concentrations were validated by comparison with inductively coupled plasma-mass spectrometry (ICP-MS) measurements ([Li] MRI  = 1.18[Li] MS , R = 0.95). Overall, a sensitivity of 0.03 mmol/L was achieved for a spatial resolution of 16 μL. Lithium distribution was uneven throughout the brain (normalized lithium content ranged from 0.4 to 1.4) and was mostly symmetrical, with consistently lower concentrations in the metencephalon (cerebellum and brainstem) and higher concentrations in the cortex. Interestingly, low lithium concentrations were also observed close to the lateral ventricles. The average brain-to-plasma lithium ratio was 0.34 ± 0.04, ranging from 0.29 to 0.39. Brain lithium concentrations were reasonably correlated with plasma lithium concentrations, with Pearson correlation factors ranging from 0.63 to 0.90. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Near-electrode imager

    DOEpatents

    Rathke, Jerome W.; Klingler, Robert J.; Woelk, Klaus; Gerald, II, Rex E.

    2000-01-01

    An apparatus, near-electrode imager, for employing nuclear magnetic resonance imaging to provide in situ measurements of electrochemical properties of a sample as a function of distance from a working electrode. The near-electrode imager uses the radio frequency field gradient within a cylindrical toroid cavity resonator to provide high-resolution nuclear magnetic resonance spectral information on electrolyte materials.

  16. Durability of hand-sewn valves in the right ventricular outlet.

    PubMed

    Nunn, Graham R; Bennetts, Jayme; Onikul, Ella

    2008-08-01

    The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained competent with regurgitant fractions of only 5% to 30% (magnetic resonance imaging angiography), and this has remained stable with time. The maximum follow-up for these valves is 5 years. No stenosis or peripheral emboli have been recognized, and no valves have been replaced to date. Hand-sewn bileaflet polytetrafluoroethylene valves in the right ventricular outlet can reliably provide competence and maintain function in the medium term. Their shape and size allow placement in young children with a reasonable expectation that they will remain competent with growth of the native annulus and not require replacement. Their durability is superior to the pericardial and polytetrafluoroethylene monocusp valves in this series.

  17. Acquisition of a Surface Plasmon Resonance Imager, Digital Microscope, and Peristaltic Pumps for Defense-Based Research

    DTIC Science & Technology

    2016-05-05

    SECURITY CLASSIFICATION OF: The goal of this proposal is to purchase the GWC Technologies, Inc. Horizontal Surface Plasmon Resonance Imaging (SPRi...Unlimited UU UU UU UU 05-05-2016 1-Feb-2014 31-Jan-2016 Final Report: Acquisition of a Surface Plasmon Resonance Imager, Digital Microscope, and...S) AND ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Surface Plasmon Resonance Imager, Digital

  18. Magneto-optical labeling of fetal neural stem cells for in vivo MRI tracking.

    PubMed

    Flexman, J A; Minoshima, S; Kim, Y; Cross, D J

    2006-01-01

    Neural stem cell therapy for neurological pathologies, such as Alzheimer's and Parkinson's disease, may delay the onset of symptoms, replace damaged neurons and/or support the survival of endogenous cells. Magnetic resonance imaging (MRI) can be used to track magnetically labeled cells in vivo to observe migration. Prior to transplantation, labeled cells must be characterized to show that they retain their intrinsic properties, such as cell proliferation into neurospheres in a supplemented environment. In vivo images must also be correlated to sensitive, histological markers. In this study, we show that fetus-derived neural stem cells can be co-labeled with superparamagnetic iron oxide and PKH26, a fluorescent dye. Labeled cells retain the ability to proliferate into neurospheres in culture, but labeling prevents neurospheres from merging in a non-adherent culture environment. After labeled NSCs were transplantation into the rat brain, their location and subsequent migration along the corpus callosum was detected using MRI. This study demonstrates an imaging paradigm with which to develop an in vivo assay for quantitatively evaluating fetal neural stem cell migration.

  19. Heart MRI

    MedlinePlus

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  20. Oncologic relevance of magnetic resonance imaging-detected threatened mesorectal fascia for patients with mid or low rectal cancer: A longitudinal analysis before and after long-course, concurrent chemoradiotherapy.

    PubMed

    Son, Il Tae; Kim, Young Hoon; Lee, Kyoung Ho; Kang, Sung Il; Kim, Duck-Woo; Shin, Eun; Lee, Keun-Wook; Ahn, Soyeon; Kim, Jae-Sung; Kang, Sung-Bum

    2017-07-01

    The oncologic importance of threatened mesorectal fascia detected with magnetic resonance imaging is obscured by the heterogeneity of preoperative treatments. We evaluated the oncologic relevance of threatened mesorectal fascia detected with consecutive magnetic resonance imaging performed before and after long-course, concurrent chemoradiotherapy (LCRT) for mid or low rectal cancer. We evaluated 196 patients who underwent total mesorectal excision with LCRT. Threatened mesorectal fascia was defined as a shortest distance from tumor to mesorectal fascia of ≤ 1 mm on magnetic resonance imaging. Multivariate analyses for disease-free survival using magnetic resonance imaging-based parameters were conducted with a Cox proportional hazard model before and after LCRT, respectively. The pathologic positivity of the circumferential resection margin was greater for threatened mesorectal fascia than for clear mesorectal fascia (pre-LCRT, 14.8% vs 3.0%, P = .004; post-LCRT, 15.4% vs 4.5%, P = .025). At a median follow-up of 68 months, 3-year disease-free survival was worse for threatened mesorectal fascia than for clear mesorectal fascia (pre-LCRT, 77.0% vs 88.1%, P = .023; post-LCRT, 76.9% vs 86.6%, P = .029). On multivariate analyses, threatened mesorectal fascia on pre-LCRT magnetic resonance imaging was an independent factor for poor disease-free survival (hazard ratio = 2.153, 95% confidence interval, 1.07-4.32, P = .031), whereas threatened mesorectal fascia on post-LCRT magnetic resonance imaging was not (hazard ratio = 1.689, 95% confidence interval, 0.77-3.66, P = .189). This study confirms that magnetic resonance imaging-detected threatened mesorectal fascia predicts poor oncologic outcomes for mid or low rectal cancer and shows that the diagnostic performance of pre-LCRT magnetic resonance imaging is different from that of post-LCRT magnetic resonance imaging. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Impact of magnetic resonance imaging on preoperative planning for breast cancer surgery.

    PubMed

    Law, Y; Cheung, Polly S Y; Lau, Silvia; Lo, Gladys G

    2013-08-01

    To review the impact of preoperative breast magnetic resonance imaging on the management of planned surgery, and the appropriateness of any resulting alterations. Retrospective review. A private hospital in Hong Kong. PATIENTS; For the 147 consecutive biopsy-proven breast cancer patients who underwent preoperative magnetic resonance imaging to determine tumour extent undergoing operation by a single surgeon between 1 January 2006 and 31 December 2009, the impact of magnetic resonance imaging findings was reviewed in terms of management alterations and their appropriateness. The most common indication for breast magnetic resonance imaging was the presence of multiple indeterminate shadows on ultrasound scans (53%), followed by ill-defined border of the main tumour on ultrasound scans (19%). In 66% (97 out of 147) of the patients, the extent of the operation was upgraded. Upgrading entailed: lumpectomy to wider lumpectomy (23 out of 97), lumpectomy to mastectomy (47 out of 97), lumpectomy to bilateral lumpectomy (15 out of 97), and other (12 out of 97). Mostly, these management changes were because magnetic resonance imaging showed more extensive disease (n=29), additional cancer foci (n=39), or contralateral disease (n=24). In five instances, upgrading was due to patient preference. In 34% (50 out of 147) of the patients, there was no change in the planned operation. Regarding 97 of the patients having altered management, in 12 the changes were considered inappropriately extensive (due to false-positive magnetic resonance imaging findings). In terms of magnetic resonance imaging detection of more extensive, multifocal, multicentric, or contralateral disease, the false-positive rate was 13% and false-negative rate 7%. Corresponding rates for sensitivity and specificity were 95% and 81%, using the final pathology as the gold standard. Preoperative magnetic resonance imaging had a clinically significant and mostly correct impact on management plans. Magnetic resonance imaging should be included as part of the preoperative investigation in patients planned for breast-conserving surgery, in whom there are doubts about the extent of the tumours based on conventional assessment.

  2. Magnetic resonance imaging is often misleading when used as an adjunct to ultrasound in the management of placenta accreta spectrum disorders.

    PubMed

    Einerson, Brett D; Rodriguez, Christina E; Kennedy, Anne M; Woodward, Paula J; Donnelly, Meghan A; Silver, Robert M

    2018-06-01

    Magnetic resonance imaging is reported to have good sensitivity and specificity in the diagnosis of placenta accreta spectrum disorders, and is often used as an adjunct to ultrasound. But the additional utility of obtaining magnetic resonance imaging to assist in the clinical management of patients with placenta accreta spectrum disorders, above and beyond the information provided by ultrasound, is unknown. We aimed to determine whether magnetic resonance imaging provides data that may inform clinical management by changing the sonographic diagnosis of placenta accreta spectrum disorders. In all, 78 patients with sonographic evidence or clinical suspicion of placenta accreta spectrum underwent magnetic resonance imaging of the abdomen and pelvis in orthogonal planes through the uterus utilizing T1- and T2-weighted imaging sequences at the University of Utah and the University of Colorado from 1997 through 2017. The magnetic resonance imaging was interpreted by radiologists with expertise in diagnosis of placenta accreta spectrum who had knowledge of the sonographic interpretation and clinical risk factors for placenta accreta spectrum disorders. The primary outcome was a change in diagnosis from sonographic interpretation that could alter clinical management, which was defined a priori. Diagnostic accuracy was verified by surgical and histopathologic diagnosis at the time of delivery. A change in diagnosis that could potentially alter clinical management occurred in 28 (36%) cases. Magnetic resonance imaging correctly changed the diagnosis in 15 (19%), and correctly confirmed the diagnosis in 34 (44%), but resulted in an incorrect change in diagnosis in 13 (17%), and an incorrect confirmation of ultrasound diagnosis in 15 (21%). Magnetic resonance imaging was not more likely to change a diagnosis in the 24 cases of posterior and lateral placental location compared to anterior location (33% vs 37%, P = .84). Magnetic resonance imaging resulted in overdiagnosis in 23% and in underdiagnosis in 14% of all cases. When ultrasound suspected severe disease (percreta) in 14 cases, magnetic resonance imaging changed the diagnosis in only 2 cases. Lastly, the proportion of accurate diagnosis with magnetic resonance imaging did not improve over time (61-65%, P = .96 for trend) despite increasing volume and increasing numbers of changed diagnoses. Magnetic resonance imaging resulted in a change in diagnosis that could alter clinical management of placenta accreta spectrum disorders in more than one third of cases, but when changed, the diagnosis was often incorrect. Given its high cost and limited clinical value, magnetic resonance imaging should not be used routinely as an adjunct to ultrasound in the diagnosis of placenta accreta spectrum until evidence for utility is clearly demonstrated by more definitive prospective studies. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Correlation Between Magnetic Resonance Imaging-Based Evaluation of Extramural Vascular Invasion and Prognostic Parameters of T3 Stage Rectal Cancer.

    PubMed

    Yu, Jing; Huang, Dong-Ya; Xu, Hui-Xin; Li, Yang; Xu, Qing

    2016-01-01

    The aim of this study was to analyze the correlation between magnetic resonance imaging-based extramural vascular invasion (EMVI) and the prognostic clinical and histological parameters of stage T3 rectal cancers. Eighty-six patients with T3 stage rectal cancer who received surgical resection without neoadjuvant therapy were included. Magnetic resonance imaging-based EMVI scores were determined. Correlations between the scores and pretreatment carcinoembryonic antigen levels, tumor differentiation grade, nodal stage, and vascular endothelial growth factor expression were analyzed using Spearman rank coefficient analysis. Magnetic resonance imaging-based EMVI scores were statistically different (P = 0.001) between histological nodal stages (N0 vs N1 vs N2). Correlations were found between magnetic resonance imaging-based EMVI scores and tumor histological grade (rs = 0.227, P = 0.035), histological nodal stage (rs = 0.524, P < 0.001), and vascular endothelial growth factor expression (rs = 0.422; P = 0.016). Magnetic resonance imaging-based EMVI score is correlated with prognostic parameters of T3 stage rectal cancers and has the potential to become an imaging biomarker of tumor aggressiveness. Magnetic resonance imaging-based EMVI may be useful in helping the multidisciplinary team to stratify T3 rectal cancer patients for neoadjuvant therapies.

  4. Diffusion weighted magnetic resonance imaging and its recent trend—a survey

    PubMed Central

    Chilla, Geetha Soujanya; Tan, Cher Heng

    2015-01-01

    Since its inception in 1985, diffusion weighted magnetic resonance imaging has been evolving and is becoming instrumental in diagnosis and investigation of tissue functions in various organs including brain, cartilage, and liver. Even though brain related pathology and/or investigation remains as the main application, diffusion weighted magnetic resonance imaging (DWI) is becoming a standard in oncology and in several other applications. This review article provides a brief introduction of diffusion weighted magnetic resonance imaging, challenges involved and recent advancements. PMID:26029644

  5. Label-free biodetection using a smartphone.

    PubMed

    Gallegos, Dustin; Long, Kenneth D; Yu, Hojeong; Clark, Peter P; Lin, Yixiao; George, Sherine; Nath, Pabitra; Cunningham, Brian T

    2013-06-07

    Utilizing its integrated camera as a spectrometer, we demonstrate the use of a smartphone as the detection instrument for a label-free photonic crystal biosensor. A custom-designed cradle holds the smartphone in fixed alignment with optical components, allowing for accurate and repeatable measurements of shifts in the resonant wavelength of the sensor. Externally provided broadband light incident upon an entrance pinhole is subsequently collimated and linearly polarized before passing through the biosensor, which resonantly reflects only a narrow band of wavelengths. A diffraction grating spreads the remaining wavelengths over the camera's pixels to display a high resolution transmission spectrum. The photonic crystal biosensor is fabricated on a plastic substrate and attached to a standard glass microscope slide that can easily be removed and replaced within the optical path. A custom software app was developed to convert the camera images into the photonic crystal transmission spectrum in the visible wavelength range, including curve-fitting analysis that computes the photonic crystal resonant wavelength with 0.009 nm accuracy. We demonstrate the functionality of the system through detection of an immobilized protein monolayer, and selective detection of concentration-dependent antibody binding to a functionalized photonic crystal. We envision the capability for an inexpensive, handheld biosensor instrument with web connectivity to enable point-of-care sensing in environments that have not been practical previously.

  6. Franck-Condon fingerprinting of vibration-tunneling spectra.

    PubMed

    Berrios, Eduardo; Sundaradevan, Praveen; Gruebele, Martin

    2013-08-15

    We introduce Franck-Condon fingerprinting as a method for assigning complex vibration-tunneling spectra. The B̃ state of thiophosgene (SCCl2) serves as our prototype. Despite several attempts, assignment of its excitation spectrum has proved difficult because of near-degenerate vibrational frequencies, Fermi resonance between the C-Cl stretching mode and the Cl-C-Cl bending mode, and large tunneling splittings due to the out-of-plane umbrella mode. Hence, the spectrum has never been fitted to an effective Hamiltonian. Our assignment approach replaces precise frequency information with intensity information, eliminating the need for double resonance spectroscopy or combination differences, neither of which have yielded a full assignment thus far. The dispersed fluorescence spectrum of each unknown vibration-tunneling state images its character onto known vibrational progressions in the ground state. By using this Franck-Condon fingerprint, we were able to determine the predominant character of several vibration-tunneling states and assign them; in other cases, the fingerprinting revealed that the states are strongly mixed and cannot be characterized with a simple normal mode assignment. The assigned transitions from vibration-tunneling wave functions that were not too strongly mixed could be fitted within measurement uncertainty by an effective vibration-tunneling Hamiltonian. A fit of all observed vibration-tunneling states will require a full resonance-tunneling Hamiltonian.

  7. Malignant Ureteral Obstruction: Functional Duration of Metallic versus Polymeric Ureteral Stents

    PubMed Central

    Chow, Po-Ming; Chiang, I-Ni; Chen, Chia-Yen; Huang, Kuo-How; Hsu, Jui-Shan; Wang, Shuo-Meng; Lee, Yuan-Ju; Yu, Hong-Jeng; Pu, Yeong-Shiau; Huang, Chao-Yuan

    2015-01-01

    Background Ureteral obstruction caused by extrinsic compression is often associated with intra-abdominal cancers. Internal drainage with ureteral stents is typically the first-line therapy to relieve such obstructions. Novel designs of ureteral stents made of different materials have been invented to achieve better drainage. In this study, we described the functional outcomes of a Resonance metallic ureteral stent (Cook Medical, Bloomington, Indiana, USA) in patients with malignant ureteral obstruction and compare the functional duration of Resonance stents with regular polymeric stents in the same cohort. Methods Cancer patients who received polymeric stents and subsequent Resonance stents for ureteral obstruction between July 2009 and November 2012 were included in a chart review. Stent failure was detected by clinical symptoms, imaging studies, and renal function tests. The functional durations of each stent were calculated, and possible factors affecting stent patency were investigated. Results A total of 50 stents were successfully inserted into 50 ureteral units in 42 patients with malignant ureteral obstruction. There were 7 antegrade stents and 43 retrograde stents. There were no major complications. Stent-related symptoms were similar in both kinds of stents. After polymeric stents were replaced with Resonance metallic stents, hydronephrosis subsided or remained stable in 90% (45/50) of the ureteral units. Serum creatinine decreased or remained stable in 90% (38/42) of these patients. The Resonance stent exhibited a mean increase in functional duration of 4 months compared with the polymeric stents (p<0.0001), and 50% (25/50) of the Resonance stents exhibited a significant increase in functional duration (more than 3 months). Pre-operative serum creatinine < 2 was associated with a substantial increase in stent duration. Conclusions Resonance stents are effective and safe in relieving malignant ureteral obstructions after polymeric stents failure. Resonance stents can provide a longer functional duration than polymeric stents and should be offered as an option for internal drainage. PMID:26267140

  8. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, P.H.; Brainard, J.R.; Jarvinen, G.D.; Ryan, R.R.

    1997-12-30

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC{sub 16}H{sub 14}N{sub 6}. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques. 10 figs.

  9. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, Paul H.; Brainard, James R.; Jarvinen, Gordon D.; Ryan, Robert R.

    1997-01-01

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC.sub.16 H.sub.14 N.sub.6. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques.

  10. Partial IGF-1 deficiency induces brain oxidative damage and edema, which are ameliorated by replacement therapy.

    PubMed

    Puche, Juan E; Muñoz, Úrsula; García-Magariño, Mariano; Sádaba, María C; Castilla-Cortázar, Inma

    2016-01-01

    Insulin-like growth factor 1 (IGF-1) induces multiple cytoprotective effects on every tissue, including the brain. Since the mechanisms by which IGF-1 produces neuroprotection are not fully understood, the aim of this work was to delve into the underlying mechanisms. IGF-1 deficient mice (Hz) were compared with wild type (WT) and Hz mice treated with low doses of IGF-1 (2 µg/100 g body weight/day) for 10 days (Hz + IGF). Gene expression, quantitative PCR, histology, and magnetic resonance imaging were performed in the three groups. IGF-1 deficiency induced increased oxidative damage determined by markers of lipid peroxidation and hypoxia, as well as gene expression of heat shock proteins, antioxidant enzymes, and molecules involved in inflammation, apoptosis, and mitochondrial protection. These changes correlated with edema and learning impairment in Hz mice. IGF-1 therapy improved all these alterations. In conclusion, IGF-1 deficiency is responsible for increased brain oxidative damage, edema, and impaired learning and memory capabilities which are rescued by IGF-1 replacement therapy. © 2016 International Union of Biochemistry and Molecular Biology.

  11. Dynamical Nuclear Magnetic Resonance Imaging of Micron-scale Liquids

    NASA Astrophysics Data System (ADS)

    Sixta, Aimee; Choate, Alexandra; Maeker, Jake; Bogat, Sophia; Tennant, Daniel; Mozaffari, Shirin; Markert, John

    We report our efforts in the development of Nuclear Magnetic Resonance Force Microscopy (NMRFM) for dynamical imaging of liquid media at the micron scale. Our probe contains microfluidic samples sealed in thin-walled (µm) quartz tubes, with a micro-oscillator sensor nearby in vacuum to maintain its high mechanical resonance quality factor. Using 10 µm spherical permalloy magnets at the oscillator tips, a 3D T1-resolved image of spin density can be obtained by reconstruction from our magnetostatics-modelled resonance slices; as part of this effort, we are exploring single-shot T1 measurements for faster dynamical imaging. We aim to further enhance imaging by using a 2 ω technique to eliminate artifact signals during the cyclic inversion of nuclear spins. The ultimate intent of these efforts is to perform magnetic resonance imaging of individual biological cells.

  12. Magnetic Field Gradient Calibration as an Experiment to Illustrate Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Seedhouse, Steven J.; Hoffmann, Markus M.

    2008-01-01

    A nuclear magnetic resonance (NMR) spectroscopy experiment for the undergraduate physical chemistry laboratory is described that encompasses both qualitative and quantitative pedagogical goals. Qualitatively, the experiment illustrates how images are obtained in magnetic resonance imaging (MRI). Quantitatively, students experience the…

  13. Imaging of juvenile spondyloarthritis. Part II: Ultrasonography and magnetic resonance imaging

    PubMed Central

    Znajdek, Michał; Gietka, Piotr; Vasilevska-Nikodinovska, Violeta; Patrovic, Lukas; Salapura, Vladka

    2017-01-01

    Juvenile spondyloarthropathies are mainly manifested by symptoms of peripheral arthritis and enthesitis. Early involvement of sacroiliac joints and spine is exceptionally rare in children; this usually happens in adulthood. Conventional radiographs visualize late inflammatory lesions. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presented classifications and radiographic presentation of juvenile spondyloarthropathies. This part discusses changes seen on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance also shows subchondral bone marrow edema, which is considered an early sign of inflammation. Ultrasonography and magnetic resonance imaging do not show specific lesions for any rheumatic disease. Nevertheless, they are conducted for early diagnosis, treatment monitoring and identifying complications. This article presents a spectrum of inflammatory changes and discusses the diagnostic value of ultrasonography and magnetic resonance imaging. PMID:29075522

  14. Vibration-synchronized magnetic resonance imaging for the detection of myocardial elasticity changes.

    PubMed

    Elgeti, Thomas; Tzschätzsch, Heiko; Hirsch, Sebastian; Krefting, Dagmar; Klatt, Dieter; Niendorf, Thoralf; Braun, Jürgen; Sack, Ingolf

    2012-04-01

    Vibration synchronized magnetic resonance imaging of harmonically oscillating tissue interfaces is proposed for cardiac magnetic resonance elastography. The new approach exploits cardiac triggered cine imaging synchronized with extrinsic harmonic stimulation (f = 22.83 Hz) to display oscillatory tissue deformations in magnitude images. Oscillations are analyzed by intensity threshold-based image processing to track wave amplitude variations over the cardiac cycle. In agreement to literature data, results in 10 volunteers showed that endocardial wave amplitudes during systole (0.13 ± 0.07 mm) were significantly lower than during diastole (0.34 ± 0.14 mm, P < 0.001). Wave amplitudes were found to decrease 117 ± 40 ms before myocardial contraction and to increase 75 ± 31 ms before myocardial relaxation. Vibration synchronized magnetic resonance imaging improves the temporal resolution of magnetic resonance elastography as it overcomes the use of extra motion encoding gradients, is less sensitive to susceptibility artifacts, and does not suffer from dynamic range constraints frequently encountered in phase-based magnetic resonance elastography. Copyright © 2012 Wiley Periodicals, Inc.

  15. Axillary silicone lymphadenopathy secondary to augmentation mammaplasty

    PubMed Central

    Dragoumis, Dimitrios M.; Assimaki, Anthoula S.; Vrizas, Triantafyllos I.; Tsiftsoglou, Aris P.

    2010-01-01

    We report a case involving a 45-year-old woman, who presented with an axillary mass 10 years after bilateral cosmetic augmentation mammaplasty. A lump was detected in the left axilla, and subsequent mammography and magnetic resonance imaging demonstrated intracapsular rupture of the left breast prosthesis. An excisional biopsy of the left axillary lesion and replacement of the ruptured implant was performed. Histological analysis showed that the axillary lump was lymph nodes containing large amounts of silicone. Silicone lymphadenopathy is an obscure complication of procedures involving the use of silicone. It is thought to occur following the transit of silicone droplets from breast implants to lymph nodes by macrophages and should always be considered as a differential diagnosis in patients in whom silicone prostheses are present. PMID:21217983

  16. PML-IRIS during Fingolimod Diagnosed after Natalizumab Discontinuation.

    PubMed

    Killestein, J; Vennegoor, A; van Golde, A E L; Bourez, R L J H; Wijlens, M L B; Wattjes, M P

    2014-01-01

    Background. Natalizumab treatment is frequently discontinued and replaced by alternative medication in multiple sclerosis (MS) patients having a high risk of progressive multifocal leukoencephalopathy (PML). Case Presentation. We report a PML case that was missed on magnetic resonance imaging (MRI) at the time Natalizumab treatment was discontinued. The patient subsequently developed a PML-immune reconstitution inflammatory syndrome after the initiation of Fingolimod treatment, suggesting that immune reconstitution may occur even during Fingolimod induced lymphopenia. Conclusion. This report highlights the need for strict drug surveillance using MRI of Natalizumab-associated MS patients at the time of drug discontinuation and beyond. This is important with respect to pharmacovigilance purposes not only for Natalizumab, but also for alternative drugs used after Natalizumab discontinuation.

  17. Computed tomography imaging and angiography - principles.

    PubMed

    Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv

    2016-01-01

    The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. © 2016 Elsevier B.V. All rights reserved.

  18. A technique for magnetic resonance imaging of equine cadaver specimens.

    PubMed

    Widmer, W R; Buckwalter, K A; Hill, M A; Fessler, J F; Ivancevich, S

    1999-01-01

    We tested an adaptation of a technique for performing magnetic resonance (MR) imaging of human cadaver limbs in the horse. The forelimbs from a normal horse were collected, frozen, and sealed with a paraffin-polymer combination prior to imaging with either a high- or midfield magnetic resonance scanner. Each forelimb was defrosted, scanned, and refrozen on two separate occasions. A five-point scale was used to evaluate the quality of each set of sagittal and transverse, T1-weighted images of each digit. There was no difference in image quality between first and second scans of either specimen (p > 0.05). We conclude that this technique allows investigators to bank tissue specimens for future magnetic resonance imaging without significant loss of image quality.

  19. Mathematical models and photogrammetric exploitation of image sensing

    NASA Astrophysics Data System (ADS)

    Puatanachokchai, Chokchai

    Mathematical models of image sensing are generally categorized into physical/geometrical sensor models and replacement sensor models. While the former is determined from image sensing geometry, the latter is based on knowledge of the physical/geometric sensor models and on using such models for its implementation. The main thrust of this research is in replacement sensor models which have three important characteristics: (1) Highly accurate ground-to-image functions; (2) Rigorous error propagation that is essentially of the same accuracy as the physical model; and, (3) Adjustability, or the ability to upgrade the replacement sensor model parameters when additional control information becomes available after the replacement sensor model has replaced the physical model. In this research, such replacement sensor models are considered as True Replacement Models or TRMs. TRMs provide a significant advantage of universality, particularly for image exploitation functions. There have been several writings about replacement sensor models, and except for the so called RSM (Replacement Sensor Model as a product described in the Manual of Photogrammetry), almost all of them pay very little or no attention to errors and their propagation. This is because, it is suspected, the few physical sensor parameters are usually replaced by many more parameters, thus presenting a potential error estimation difficulty. The third characteristic, adjustability, is perhaps the most demanding. It provides an equivalent flexibility to that of triangulation using the physical model. Primary contributions of this thesis include not only "the eigen-approach", a novel means of replacing the original sensor parameter covariance matrices at the time of estimating the TRM, but also the implementation of the hybrid approach that combines the eigen-approach with the added parameters approach used in the RSM. Using either the eigen-approach or the hybrid approach, rigorous error propagation can be performed during image exploitation. Further, adjustability can be performed when additional control information becomes available after the TRM has been implemented. The TRM is shown to apply to imagery from sensors having different geometries, including an aerial frame camera, a spaceborne linear array sensor, an airborne pushbroom sensor, and an airborne whiskbroom sensor. TRM results show essentially negligible differences as compared to those from rigorous physical sensor models, both for geopositioning from single and overlapping images. Simulated as well as real image data are used to address all three characteristics of the TRM.

  20. 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge when mammography and ultrasound fail.

    PubMed

    Lubina, Nóra; Schedelbeck, Ulla; Roth, Anne; Weng, Andreas Max; Geissinger, Eva; Hönig, Arnd; Hahn, Dietbert; Bley, Thorsten Alexander

    2015-05-01

    To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p < 0.0001). MRI of the breast at 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. • Breast MRI is an excellent diagnostic tool for patients with nipple discharge. • MRI of the breast reveals malignant lesions despite inconspicuous mammography and ultrasound. • MRI of the breast has greater sensitivity and specificity than galactography. • Excellent correlation of lesion size measured at MRI and histopathology was found.

  1. Spirometer-controlled cine magnetic resonance imaging used to diagnose tracheobronchomalacia in paediatric patients.

    PubMed

    Ciet, Pierluigi; Wielopolski, Piotr; Manniesing, Rashindra; Lever, Sandra; de Bruijne, Marleen; Morana, Giovanni; Muzzio, Pier Carlo; Lequin, Maarten H; Tiddens, Harm A W M

    2014-01-01

    Tracheobronchomalacia (TBM) is defined as an excessive collapse of the intrathoracic trachea. Bronchoscopy is the gold standard for diagnosing TBM; however it has major disadvantages, such as general anaesthesia. Cine computed tomography (CT) is a noninvasive alternative used to diagnose TBM, but its use in children is restricted by ionising radiation. Our aim was to evaluate the feasibility of spirometer-controlled cine magnetic resonance imaging (MRI) as an alternative to cine-CT in a retrospective study. 12 children with a mean age (range) of 12 years (7-17 years), suspected of having TBM, underwent cine-MRI. Static scans were acquired at end-inspiration and expiration covering the thorax using a three-dimensional spoiled gradient echo sequence. Three-dimensional dynamic scans were performed covering only the central airways. TBM was defined as a decrease of the trachea or bronchi diameter >50% at end-expiration in the static and dynamic scans. The success rate of the cine-MRI protocol was 92%. Cine-MRI was compared with bronchoscopy or chest CT in seven subjects. TBM was diagnosed by cine-MRI in seven (58%) out of 12 children and was confirmed by bronchoscopy or CT. In four patients, cine-MRI demonstrated tracheal narrowing that was not present in the static scans. Spirometer controlled cine-MRI is a promising technique to assess TBM in children and has the potential to replace bronchoscopy.

  2. The Diagnostic Performance of Multiparametric Magnetic Resonance Imaging to Detect Significant Prostate Cancer.

    PubMed

    Thompson, J E; van Leeuwen, P J; Moses, D; Shnier, R; Brenner, P; Delprado, W; Pulbrook, M; Böhm, M; Haynes, A M; Hayen, A; Stricker, P D

    2016-05-01

    We assess the accuracy of multiparametric magnetic resonance imaging for significant prostate cancer detection before diagnostic biopsy in men with an abnormal prostate specific antigen/digital rectal examination. A total of 388 men underwent multiparametric magnetic resonance imaging, including T2-weighted, diffusion weighted and dynamic contrast enhanced imaging before biopsy. Two radiologists used PI-RADS to allocate a score of 1 to 5 for suspicion of significant prostate cancer (Gleason 7 with more than 5% grade 4). PI-RADS 3 to 5 was considered positive. Transperineal template guided mapping biopsy of 18 regions (median 30 cores) was performed with additional manually directed cores from magnetic resonance imaging positive regions. The anatomical location, size and grade of individual cancer areas in the biopsy regions (18) as the primary outcome and in prostatectomy specimens (117) as the secondary outcome were correlated to the magnetic resonance imaging positive regions. Of the 388 men who were enrolled in the study 344 were analyzed. Multiparametric magnetic resonance imaging was positive in 77.0% of patients, 62.5% had prostate cancer and 41.6% had significant prostate cancer. The detection of significant prostate cancer by multiparametric magnetic resonance imaging had a sensitivity of 96%, specificity of 36%, negative predictive value of 92% and positive predictive value of 52%. Adding PI-RADS to the multivariate model, including prostate specific antigen, digital rectal examination, prostate volume and age, improved the AUC from 0.776 to 0.879 (p <0.001). Anatomical concordance analysis showed a low mismatch between the magnetic resonance imaging positive regions and biopsy positive regions (4 [2.9%]), and the significant prostate cancer area in the radical prostatectomy specimen (3 [3.3%]). In men with an abnormal prostate specific antigen/digital rectal examination, multiparametric magnetic resonance imaging detected significant prostate cancer with an excellent negative predictive value and moderate positive predictive value. The use of multiparametric magnetic resonance imaging to diagnose significant prostate cancer may result in a substantial number of unnecessary biopsies while missing a minimum of significant prostate cancers. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. The Importance of Neurogenic Inflammation in Blast-Induced Neurotrauma

    DTIC Science & Technology

    2013-01-01

    mild/moderate BINT are imaged by magnetic resonance imaging ( MRI ) to visualize potential macrophage infiltration; blood-brain barrier (BBB) disturbance...TERMS blast, traumatic brain injury, brain, inflammation, magnetic resonance imaging , mice 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...monitoring the success of therapeutic interventions. In this annual report we have utilized current live imaging methods (i.e. magnetic resonance

  4. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    ERIC Educational Resources Information Center

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  5. Neurilemmoma of the glans penis: ultrasonography and magnetic resonance imaging findings.

    PubMed

    Jung, Dae Chul; Hwang, Sung Il; Jung, Sung Il; Kim, Sun Ho; Kim, Seung Hyup

    2006-01-01

    Neurilemmoma of the glans penis is rare, and no imaging findings have been reported. A case of neurilemmoma of the glans penis is presented. Ultrasonography (US) and magnetic resonance imaging revealed a well-defined small mass in the glans penis. The mass appeared hypoechoic on gray-scale US and hypervascular on color Doppler US. Magnetic resonance imaging revealed high signal intensity of the mass on a T2-weighted image and strong enhancement on a contrast-enhanced T1-weighted image.

  6. Human tooth and root canal morphology reconstruction using magnetic resonance imaging.

    PubMed

    Drăgan, Oana Carmen; Fărcăşanu, Alexandru Ştefan; Câmpian, Radu Septimiu; Turcu, Romulus Valeriu Flaviu

    2016-01-01

    Visualization of the internal and external root canal morphology is very important for a successful endodontic treatment; however, it seems to be difficult considering the small size of the tooth and the complexity of the root canal system. Film-based or digital conventional radiographic techniques as well as cone beam computed tomography provide limited information on the dental pulp anatomy or have harmful effects. A new non-invasive diagnosis tool is magnetic resonance imaging, due to its ability of imaging both hard and soft tissues. The aim of this study was to demonstrate magnetic resonance imaging to be a useful tool for imaging the anatomic conditions of the external and internal root canal morphology for endodontic purposes. The endodontic system of one freshly extracted wisdom tooth, chosen for its well-known anatomical variations, was mechanically shaped using a hybrid technique. After its preparation, the tooth was immersed into a recipient with saline solution and magnetic resonance imaged immediately. A Bruker Biospec magnetic resonance imaging scanner operated at 7.04 Tesla and based on Avance III radio frequency technology was used. InVesalius software was employed for the 3D reconstruction of the tooth scanned volume. The current ex-vivo experiment shows the accurate 3D volume rendered reconstruction of the internal and external morphology of a human extracted and endodontically treated tooth using a dataset of images acquired by magnetic resonance imaging. The external lingual and vestibular views of the tooth as well as the occlusal view of the pulp chamber, the access cavity, the distal canal opening on the pulp chamber floor, the coronal third of the root canals, the degree of root separation and the apical fusion of the two mesial roots, details of the apical region, root canal curvatures, furcal region and interradicular root grooves could be clearly bordered. Magnetic resonance imaging offers 3D image datasets with more information than the conventional radiographic techniques. Due to its ability of imaging both hard and soft dental tissues, magnetic resonance imaging can be successfully used as a 3D diagnostic imaging technique in dentistry. When choosing the imaging method, dental clinicians should weight the benefit-risk ratio, taking into account the costs associated to magnetic resonance imaging and the harmful effects of ionizing radiations when cone beam computed tomography or conventional x-ray are used.

  7. Tensor voting for image correction by global and local intensity alignment.

    PubMed

    Jia, Jiaya; Tang, Chi-Keung

    2005-01-01

    This paper presents a voting method to perform image correction by global and local intensity alignment. The key to our modeless approach is the estimation of global and local replacement functions by reducing the complex estimation problem to the robust 2D tensor voting in the corresponding voting spaces. No complicated model for replacement function (curve) is assumed. Subject to the monotonic constraint only, we vote for an optimal replacement function by propagating the curve smoothness constraint using a dense tensor field. Our method effectively infers missing curve segments and rejects image outliers. Applications using our tensor voting approach are proposed and described. The first application consists of image mosaicking of static scenes, where the voted replacement functions are used in our iterative registration algorithm for computing the best warping matrix. In the presence of occlusion, our replacement function can be employed to construct a visually acceptable mosaic by detecting occlusion which has large and piecewise constant color. Furthermore, by the simultaneous consideration of color matches and spatial constraints in the voting space, we perform image intensity compensation and high contrast image correction using our voting framework, when only two defective input images are given.

  8. Magnetic resonance imaging of appendicular musculoskeletal infection.

    PubMed

    Lalam, Radhesh K; Cassar-Pullicino, Victor N; Tins, Bernhard J

    2007-06-01

    Appendicular skeletal infection includes osseous and extraosseous infections. Skeletal infection needs early diagnosis and appropriate management to prevent long-term morbidity. Magnetic resonance imaging is the best imaging modality to diagnose skeletal infection early in most circumstances. This article describes the role of magnetic resonance imaging in relation to the other available imaging modalities in the diagnosis of skeletal infection. Special circumstances such as diabetic foot, postoperative infection, and chronic recurrent multifocal osteomyelitis are discussed separately.

  9. Progression of Hypertrophy and Myocardial Fibrosis in Aortic Stenosis: A Multicenter Cardiac Magnetic Resonance Study.

    PubMed

    Everett, Russell J; Tastet, Lionel; Clavel, Marie-Annick; Chin, Calvin W L; Capoulade, Romain; Vassiliou, Vassilios S; Kwiecinski, Jacek; Gomez, Miquel; van Beek, Edwin J R; White, Audrey C; Prasad, Sanjay K; Larose, Eric; Tuck, Christopher; Semple, Scott; Newby, David E; Pibarot, Philippe; Dweck, Marc R

    2018-06-01

    Aortic stenosis is accompanied by progressive left ventricular hypertrophy and fibrosis. We investigated the natural history of these processes in asymptomatic patients and their potential reversal post-aortic valve replacement (AVR). Asymptomatic and symptomatic patients with aortic stenosis underwent repeat echocardiography and magnetic resonance imaging. Changes in peak aortic-jet velocity, left ventricular mass index, diffuse fibrosis (indexed extracellular volume), and replacement fibrosis (late gadolinium enhancement [LGE]) were quantified. In 61 asymptomatic patients (43% mild, 34% moderate, and 23% severe aortic stenosis), significant increases in peak aortic-jet velocity, left ventricular mass index, indexed extracellular volume, and LGE mass were observed after 2.1±0.7 years, with the most rapid progression observed in patients with most severe stenosis. Patients with baseline midwall LGE (n=16 [26%]; LGE mass, 2.5 g [0.8-4.8 g]) demonstrated particularly rapid increases in scar burden (78% [50%-158%] increase in LGE mass per year). In 38 symptomatic patients (age, 66±8 years; 76% men) who underwent AVR, there was a 19% (11%-25%) reduction in left ventricular mass index ( P <0.0001) and an 11% (4%-16%) reduction in indexed extracellular volume ( P =0.003) 0.9±0.3 years after surgery. By contrast midwall LGE (n=10 [26%]; mass, 3.3 g [2.6-8.0 g]) did not change post-AVR (n=10; 3.5 g [2.1-8.0 g]; P =0.23), with no evidence of regression even out to 2 years. In patients with aortic stenosis, cellular hypertrophy and diffuse fibrosis progress in a rapid and balanced manner but are reversible after AVR. Once established, midwall LGE also accumulates rapidly but is irreversible post valve replacement. Given its adverse long-term prognosis, prompt AVR when midwall LGE is first identified may improve clinical outcomes. URL: https://www.clinicaltrials.gov. Unique identifiers: NCT01755936 and NCT01679431. © 2018 The Authors.

  10. Overview of Imaging Tests

    MedlinePlus

    ... Overview of Imaging Tests Angiography Computed Tomography (CT) Magnetic Resonance Imaging (MRI) Plain X-Rays Radionuclide Scanning ... and radionuclide scanning Sound waves, as in ultrasonography Magnetic fields, as in magnetic resonance imaging (MRI) Substances ...

  11. Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts

    PubMed Central

    Wolf, Marcel; Bäumer, Philipp; Pedro, Maria; Dombert, Thomas; Staub, Frank; Heiland, Sabine; Bendszus, Martin; Pham, Mirko

    2014-01-01

    Sciatic nerve palsy related to hip replacement surgery (HRS) is among the most common causes of sciatic neuropathies. The sciatic nerve may be injured by various different periprocedural mechanisms. The precise localization and extension of the nerve lesion, the determination of nerve continuity, lesion severity, and fascicular lesion distribution are essential for assessing the potential of spontaneous recovery and thereby avoiding delayed or inappropriate therapy. Adequate therapy is in many cases limited to conservative management, but in certain cases early surgical exploration and release of the nerve is indicated. Nerve-conduction-studies and electromyography are essential in the diagnosis of nerve injuries. In postsurgical nerve injuries, additional diagnostic imaging is important as well, in particular to detect or rule out direct mechanical compromise. Especially in the presence of metallic implants, commonly applied diagnostic imaging tests generally fail to adequately visualize nervous tissue. MRI has been deemed problematic due to implant-related artifacts after HRS. In this study, we describe for the first time the spectrum of imaging findings of Magnetic Resonance neurography (MRN) employing pulse sequences relatively insensitive to susceptibility artifacts (susceptibility insensitive MRN, siMRN) in a series of 9 patients with HRS procedure related sciatic nerve palsy. We were able to determine the localization and fascicular distribution of the sciatic nerve lesion in all 9 patients, which clearly showed on imaging predominant involvement of the peroneal more than the tibial division of the sciatic nerve. In 2 patients siMRN revealed direct mechanical compromise of the nerve by surgical material, and in one of these cases indication for surgical release of the sciatic nerve was based on siMRN. Thus, in selected cases of HRS related neuropathies, especially when surgical exploration of the nerve is considered, siMRN, with its potential to largely overcome implant related artifacts, is a useful diagnostic addition to nerve-conduction-studies and electromyography. PMID:24558483

  12. Synthesis of Water-Dispersible Mn2+ Functionalized Silicon Nanoparticles under Room Temperature and Atmospheric Pressure for Fluorescence and Magnetic Resonance Dual-Modality Imaging.

    PubMed

    Dou, Ya-Kun; Chen, Yang; He, Xi-Wen; Li, Wen-You; Li, Yu-Hao; Zhang, Yu-Kui

    2017-11-07

    Silicon nanoparticles (Si NPs) have been widely used in fluorescence imaging. However, rigorous synthesis conditions and the single modality imaging limit the further development of Si NPs in the field of biomedical imaging. Here, we reported a method for synthesizing water-dispersible Mn 2+ functionalized Si NPs (Mn-Si NPs) under mild experimental conditions for fluorescence and magnetic resonance dual-modality imaging. The whole synthesis process was completed under room temperature and atmospheric pressure, and no special and expensive equipment was required. The synthetic nanoparticles, with favorable pH stability, NaCl stability, photostability, and low toxicity, emitted green fluorescence (512 nm). At the same time, the nanoparticles also demonstrated excellent magnetic resonance imaging ability. In vitro, their T 1 -weighted magnetic resonance imaging effect was obvious, and the value of longitudinal relaxation degree r 1 reached 4.25 mM -1 s -1 . On the basis of their good biocompatibility, Mn-Si NPs were successfully used for the fluorescence imaging as well as magnetic resonance imaging in vivo.

  13. Preoperative evaluation of venous systems with 3-dimensional contrast-enhanced magnetic resonance venography in brain tumors: comparison with time-of-flight magnetic resonance venography and digital subtraction angiography.

    PubMed

    Lee, Jong-Myung; Jung, Shin; Moon, Kyung-Sub; Seo, Jeong-Jin; Kim, In-Young; Jung, Tae-Young; Lee, Jung-Kil; Kang, Sam-Suk

    2005-08-01

    Recent developments in magnetic resonance (MR) technology now enable the use of MR venography, providing 3-dimensional (3D) images of intracranial venous structures. The purpose of this study was to assess the usefulness of 3D contrast-enhanced MR venography (CE MRV) in the evaluation of intracranial venous system for surgical planning of brain tumors. Forty patients underwent 3D CE MRV, as well as 25 patients, 2-dimensional (2D) time-of-flight (TOF) MR venography in axial and sagittal planes; and 10 patients, digital subtraction angiography. We determined the number of visualized sinuses and cortical veins. Degree of visualization of the intracranial venous system on 3D CE MRV was compared with that of 2D TOF MR venography and digital subtraction angiography as a standard. We also assessed the value of 3D CE MRV in the investigation of sinus occlusion or localization of cortical draining veins preoperatively. Superficial cortical veins and the dural sinus were better visualized on 3D CE MRV than on 2D TOF MR venography. Both MR venographic techniques visualized superior sagittal sinus, lateral sinus, sigmoid sinus, straight sinus, and internal cerebral vein and provided more detailed information by showing obstructed sinuses in brain tumors. Only 3D CE MRV showed superficial cortical draining veins. However, it was difficult to accurately evaluate the presence of cortical collateral venous drainage. Although we do not yet advocate MR venography to replace conventional angiography as the imaging standard for brain tumors, 3D CE MRV can be regarded as a valuable diagnostic method just in evaluating the status of major sinuses and localization of the cortical draining veins.

  14. Functional Magnetic Resonance Imaging in Alzheimer' Disease Drug Development.

    PubMed

    Holiga, Stefan; Abdulkadir, Ahmed; Klöppel, Stefan; Dukart, Juergen

    2018-01-01

    While now commonly applied for studying human brain function the value of functional magnetic resonance imaging in drug development has only recently been recognized. Here we describe the different functional magnetic resonance imaging techniques applied in Alzheimer's disease drug development with their applications, implementation guidelines, and potential pitfalls.

  15. Battery voltage-balancing applications of disk-type radial mode Pb(Zr • Ti)O3 ceramic resonator

    NASA Astrophysics Data System (ADS)

    Thenathayalan, Daniel; Lee, Chun-gu; Park, Joung-hu

    2017-10-01

    In this paper, we propose a novel technique to build a charge-balancing circuit for series-connected battery strings using various kinds of disk-type ceramic Pb(Zr • Ti)O3 piezoelectric resonators (PRs). The use of PRs replaces the whole external battery voltage-balancer circuit, which consists mainly of a bulky magnetic element. The proposed technique is validated using different ceramic PRs and the results are analyzed in terms of their physical properties. A series-connected battery string with a voltage rating of 61.5 V is set as a hardware prototype under test, then the power transfer efficiency of the system is measured at different imbalance voltages. The performance of the proposed battery voltage-balancer circuit employed with a PR is also validated through hardware implementation. Furthermore, the temperature distribution image of the PR is obtained to compare power transfer efficiency and thermal stress under different operating conditions. The test results show that the battery voltage-balancer circuit can be successfully implemented using PRs with the maximum power conversion efficiency of over 96% for energy storage systems.

  16. k and q Dedicated to Paul Callaghan

    NASA Astrophysics Data System (ADS)

    Blümich, Bernhard

    2016-06-01

    The symbols k and q denote wave numbers in scattering experiments as well as in NMR imaging. Their exploration in NMR is intimately linked to the legacy of Paul Callaghan with his books Magnetic Resonance Microscopy and Translational Dynamics & Magnetic Resonance (Oxford University Press, Oxford 1991 and 2011) placing their focus with their titles on k and q, respectively. Some aspects of k and q have been revisited in the Paul Callaghan lecture of the author at the ISMAR Conference in Shanghai in 2015, which are reviewed here. In particular, there are two definitions of q, one relating to diffusive displacement (q) and the other to coherent flow (qv). Concerning the latter, it turns out, that in the short gradient pulse limit, the common anti-phase pulsed field-gradient scheme can be replaced with schemes employing three and more gradient pulses, which derive from differentiation rules in numerical analysis. Practical gradient modulation schemes with finite gradient pulse widths follow from these to measure velocity with improved accuracy. This approach can be expanded to acceleration and higher order transport coefficients with applications to measurements of flow and potentially also restricted diffusion.

  17. In vivo experiences with magnetic resonance imaging scans in Vibrant Soundbridge type 503 implantees.

    PubMed

    Todt, I; Mittmann, P; Ernst, A; Mutze, S; Rademacher, G

    2018-05-01

    To observe the effects of magnetic resonance imaging scans in Vibrant Soundbridge 503 implantees at 1.5T in vivo. In a prospective case study of five Vibrant Soundbridge 503 implantees, 1.5T magnetic resonance imaging scans were performed with and without a headband. The degree of pain was evaluated using a visual analogue scale. Scan-related pure tone audiogram and audio processor fitting changes were assessed. In all patients, magnetic resonance imaging scans were performed without any degree of pain or change in pure tone audiogram or audio processor fitting, even without a headband. In this series, 1.5T magnetic resonance imaging scans were performed with the Vibrant Soundbridge 503 without complications. Limitations persist in terms of magnetic artefacts.

  18. A comparative analysis of 7.0-Tesla magnetic resonance imaging and histology measurements of knee articular cartilage in a canine posterolateral knee injury model: a preliminary analysis.

    PubMed

    Pepin, Scott R; Griffith, Chad J; Wijdicks, Coen A; Goerke, Ute; McNulty, Margaret A; Parker, Josh B; Carlson, Cathy S; Ellermann, Jutta; LaPrade, Robert F

    2009-11-01

    There has recently been increased interest in the use of 7.0-T magnetic resonance imaging for evaluating articular cartilage degeneration and quantifying the progression of osteoarthritis. The purpose of this study was to evaluate articular cartilage cross-sectional area and maximum thickness in the medial compartment of intact and destabilized canine knees using 7.0-T magnetic resonance images and compare these results with those obtained from the corresponding histologic sections. Controlled laboratory study. Five canines had a surgically created unilateral grade III posterolateral knee injury that was followed for 6 months before euthanasia. The opposite, noninjured knee was used as a control. At necropsy, 3-dimensional gradient echo images of the medial tibial plateau of both knees were obtained using a 7.0-T magnetic resonance imaging scanner. Articular cartilage area and maximum thickness in this site were digitally measured on the magnetic resonance images. The proximal tibias were processed for routine histologic analysis with hematoxylin and eosin staining. Articular cartilage area and maximum thickness were measured in histologic sections corresponding to the sites of the magnetic resonance slices. The magnetic resonance imaging results revealed an increase in articular cartilage area and maximum thickness in surgical knees compared with control knees in all specimens; these changes were significant for both parameters (P <.05 for area; P <.01 for thickness). The average increase in area was 14.8% and the average increase in maximum thickness was 15.1%. The histologic results revealed an average increase in area of 27.4% (P = .05) and an average increase in maximum thickness of 33.0% (P = .06). Correlation analysis between the magnetic resonance imaging and histology data revealed that the area values were significantly correlated (P < .01), but the values for thickness obtained from magnetic resonance imaging were not significantly different from the histology sections (P > .1). These results demonstrate that 7.0-T magnetic resonance imaging provides an alternative method to histology to evaluate early osteoarthritic changes in articular cartilage in a canine model by detecting increases in articular cartilage area. The noninvasive nature of 7.0-T magnetic resonance imaging will allow for in vivo monitoring of osteoarthritis progression and intervention in animal models and humans for osteoarthritis.

  19. Flaw investigation in a multi-layered, multi-material composite: Using air-coupled ultrasonic resonance imaging

    NASA Astrophysics Data System (ADS)

    Livings, R. A.; Dayal, V.; Barnard, D. J.; Hsu, D. K.

    2012-05-01

    Ceramic tiles are the main ingredient of a multi-material, multi-layered composite being considered for the modernization of tank armors. The high stiffness, low attenuation, and precise dimensions of these uniform tiles make them remarkable resonators when driven to vibrate. Defects in the tile, during manufacture or after usage, are expected to change the resonance frequencies and resonance images of the tile. The comparison of the resonance frequencies and resonance images of a pristine tile/lay-up to a defective tile/lay-up will thus be a quantitative damage metric. By examining the vibrational behavior of these tiles and the composite lay-up with Finite Element Modeling and analytical plate vibration equations, the development of a new Nondestructive Evaluation technique is possible. This study examines the development of the Air-Coupled Ultrasonic Resonance Imaging technique as applied to a hexagonal ceramic tile and a multi-material, multi-layered composite.

  20. Charged particle accelerator grating

    DOEpatents

    Palmer, Robert B.

    1986-01-01

    A readily disposable and replaceable accelerator grating for a relativistic particle accelerator. The grating is formed for a plurality of liquid droplets that are directed in precisely positioned jet streams to periodically dispose rows of droplets along the borders of a predetermined particle beam path. A plurality of lasers are used to direct laser beams into the droplets, at predetermined angles, thereby to excite the droplets to support electromagnetic accelerating resonances on their surfaces. Those resonances operate to accelerate and focus particles moving along the beam path. As the droplets are distorted or destroyed by the incoming radiation, they are replaced at a predetermined frequency by other droplets supplied through the jet streams.

  1. Charged particle accelerator grating

    DOEpatents

    Palmer, R.B.

    1985-09-09

    A readily disposable and replaceable accelerator grating for a relativistic particle accelerator is described. The grating is formed for a plurality of liquid droplets that are directed in precisely positioned jet streams to periodically dispose rows of droplets along the borders of a predetermined particle beam path. A plurality of lasers are used to direct laser beams onto the droplets, at predetermined angles, thereby to excite the droplets to support electromagnetic accelerating resonances on their surfaces. Those resonances operate to accelerate and focus particles moving along the beam path. As the droplets are distorted or destroyed by the incoming radiation, they are replaced at a predetermined frequency by other droplets supplied through the jet streams.

  2. Charged particle accelerator grating

    DOEpatents

    Palmer, Robert B.

    1986-09-02

    A readily disposable and replaceable accelerator grating for a relativistic particle accelerator. The grating is formed for a plurality of liquid droplets that are directed in precisely positioned jet streams to periodically dispose rows of droplets along the borders of a predetermined particle beam path. A plurality of lasers are used to direct laser beams into the droplets, at predetermined angles, thereby to excite the droplets to support electromagnetic accelerating resonances on their surfaces. Those resonances operate to accelerate and focus particles moving along the beam path. As the droplets are distorted or destroyed by the incoming radiation, they are replaced at a predetermined frequency by other droplets supplied through the jet streams.

  3. Impact of Lesion Visibility on Transrectal Ultrasound on the Prediction of Clinically Significant Prostate Cancer (Gleason Score 3 + 4 or Greater) with Transrectal Ultrasound-Magnetic Resonance Imaging Fusion Biopsy.

    PubMed

    Garcia-Reyes, Kirema; Nguyen, Hao G; Zagoria, Ronald J; Shinohara, Katsuto; Carroll, Peter R; Behr, Spencer C; Westphalen, Antonio C

    2017-09-20

    The purpose of this study was to estimate the impact of lesion visibility with transrectal ultrasound on the prediction of clinically significant prostate cancer with transrectal ultrasound-magnetic resonance imaging fusion biopsy. This HIPAA (Health Insurance Portability and Accountability Act) compliant, institutional review board approved, retrospective study was performed in 178 men who were 64.7 years old with prostate specific antigen 8.9 ng/ml. They underwent transrectal ultrasound-magnetic resonance imaging fusion biopsy from January 2013 to September 2016. Visible lesions on magnetic resonance imaging were assigned a PI-RADS™ (Prostate Imaging Reporting and Data System), version 2 score of 3 or greater. Transrectal ultrasound was positive when a hypoechoic lesion was identified. We used a 3-level, mixed effects logistic regression model to determine how transrectal ultrasound-magnetic resonance imaging concordance predicted the presence of clinically significant prostate cancer. The diagnostic performance of the 2 methods was estimated using ROC curves. A total of 1,331 sextants were targeted by transrectal ultrasound-magnetic resonance imaging fusion or systematic biopsies, of which 1,037 were negative, 183 were Gleason score 3 + 3 and 111 were Gleason score 3 + 4 or greater. Clinically significant prostate cancer was diagnosed by transrectal ultrasound and magnetic resonance imaging alone at 20.5% and 19.7% of these locations, respectively. Men with positive imaging had higher odds of clinically significant prostate cancer than men without visible lesions regardless of modality (transrectal ultrasound OR 14.75, 95% CI 5.22-41.69, magnetic resonance imaging OR 12.27, 95% CI 6.39-23.58 and the 2 modalities OR 28.68, 95% CI 14.45-56.89, all p <0.001). The ROC AUC to detect clinically significant prostate cancer using the 2 methods (0.85, 95% CI 0.81-0.89) was statistically greater than that of transrectal ultrasound alone (0.80, 95% CI 0.76-0.85, p = 0.001) and magnetic resonance imaging alone (0.83, 95% CI 0.79-0.87, p = 0.04). The sensitivity and specificity of transrectal ultrasound were 42.3% and 91.6%, and the sensitivity and specificity of magnetic resonance imaging were 62.2% and 84.1%, respectively. Lesion visibility on magnetic resonance imaging or transrectal ultrasound denotes a similar probability of clinically significant prostate cancer. This probability is greater when each examination is positive. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Magnetic resonance imaging-compatible tactile sensing device based on a piezoelectric array.

    PubMed

    Hamed, Abbi; Masamune, Ken; Tse, Zion Tsz Ho; Lamperth, Michael; Dohi, Takeyoshi

    2012-07-01

    Minimally invasive surgery is a widely used medical technique, one of the drawbacks of which is the loss of direct sense of touch during the operation. Palpation is the use of fingertips to explore and make fast assessments of tissue morphology. Although technologies are developed to equip minimally invasive surgery tools with haptic feedback capabilities, the majority focus on tissue stiffness profiling and tool-tissue interaction force measurement. For greatly increased diagnostic capability, a magnetic resonance imaging-compatible tactile sensor design is proposed, which allows minimally invasive surgery to be performed under image guidance, combining the strong capability of magnetic resonance imaging soft tissue and intuitive palpation. The sensing unit is based on a piezoelectric sensor methodology, which conforms to the stringent mechanical and electrical design requirements imposed by the magnetic resonance environment The sensor mechanical design and the device integration to a 0.2 Tesla open magnetic resonance imaging scanner are described, together with the device's magnetic resonance compatibility testing. Its design limitations and potential future improvements are also discussed. A tactile sensing unit based on a piezoelectric sensor principle is proposed, which is designed for magnetic resonance imaging guided interventions.

  5. Imaging agents for in vivo magnetic resonance and scintigraphic imaging

    DOEpatents

    Engelstad, Barry L.; Raymond, Kenneth N.; Huberty, John P.; White, David L.

    1991-01-01

    Methods are provided for in vivo magnetic resonance imaging and/or scintigraphic imaging of a subject using chelated transition metal and lanthanide metal complexes. Novel ligands for these complexes are provided.

  6. Off-resonance saturation magnetic resonance imaging of superparamagnetic polymeric micelles.

    PubMed

    Khemtong, Chalermchai; Kessinger, Chase W; Togao, Osamu; Ren, Jimin; Takahashi, Masaya; Sherry, A Dean; Gao, Jinming

    2009-01-01

    An off-resonance saturation (ORS) method was used for magnetic resonance imaging of superparamagnetic polymeric micelles (SPPM). SPPM was produced by encapsulating a cluster of magnetite nanoparticles (9.9+/-0.4 nm in diameter) in poly(ethylene glycol)-b-poly(D,L-lactide) (PEG-PLA) copolymer micelles (micelle diameter: 60+/-9 nm). In ORS MRI, a selective radiofrequency (RF) pulse was applied at an off-resonance position (0-50 ppm) from the bulk water signal, and the SPPM particles were visualized by the contrast on a division image constructed from two images acquired with and without pre-saturation. Here, the effects of saturation offset frequencies, saturation durations, and RF powers on ORS contrasts were investigated as these parameters are critical for optimization of ORS MRI for in vivo imaging applications. The ability to turn "ON" and "OFF" ORS contrast of SPPM solutions permits for an accurate image subtraction and a contrast enhancement to visualize SPPM probes for in vivo imaging of cancer.

  7. Finding the Truth in Medical Imaging: Painting the Picture of Appropriateness for Magnetic Resonance Imaging in Canada.

    PubMed

    Vanderby, Sonia; Peña-Sánchez, Juan Nicolás; Kalra, Neil; Babyn, Paul

    2015-11-01

    Questions about the appropriateness of medical imaging exams, particularly related to magnetic resonance exams, have arisen in recent years. However, the prevalence of inappropriate imaging in Canada is unclear as inappropriate exam proportion estimates are often based on studies from other countries. Hence, we sought to compare and summarize Canadian studies related to magnetic resonance imaging appropriateness. We completed a systematic literature search identifying studies related to magnetic resonance appropriateness in Canada published between 2003 and 2013. Two researchers independently searched and evaluated the literature available. Articles that studied or discussed magnetic resonance appropriateness in Canada were selected based on titles, abstracts, and, where necessary, full article review. Articles relating solely to other modalities or countries were excluded, as were imaging appropriateness guidelines and reviews. Fourteen articles were included: 8 quantitative studies and 6 editorials/commentaries. The quantitative studies reported inappropriate proportions of magnetic resonance exams ranging from 2%-28.5%. Our review also revealed substantial variations among study methods and analyses. Common topics identified among editorials/commentaries included reasons for obtaining imaging in general and for selecting a specific modality, consequences of inappropriate imaging, factors contributing to demand, and suggested means of mitigating inappropriate medical imaging use. The available studies do not support the common claim that 30% of medical imaging exams in Canada are inappropriate. The actual proportion of inappropriate magnetic resonance exams has not yet been established conclusively in Canada. Further research, particularly on a widespread national scale, is needed to guide healthcare policies. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Predictive value of magnetic resonance imaging determined tumor contact length for extracapsular extension of prostate cancer.

    PubMed

    Baco, Eduard; Rud, Erik; Vlatkovic, Ljiljana; Svindland, Aud; Eggesbø, Heidi B; Hung, Andrew J; Matsugasumi, Toru; Bernhard, Jean-Christophe; Gill, Inderbir S; Ukimura, Osamu

    2015-02-01

    Tumor contact length is defined as the amount of prostate cancer in contact with the prostatic capsule. We evaluated the ability of magnetic resonance imaging determined tumor contact length to predict microscopic extracapsular extension compared to existing predictors of extracapsular extension. We retrospectively analyzed the records of 111 consecutive patients with magnetic resonance imaging/ultrasound fusion targeted, biopsy proven prostate cancer who underwent radical prostatectomy from January 2010 to July 2013. Median patient age was 64 years and median prostate specific antigen was 8.9 ng/ml. Clinical stage was cT1 in 93 cases (84%) and cT2 in 18 (16%). Postoperative pathological analysis confirmed pT2 in 71 patients (64%) and pT3 in 40 (36%). We evaluated 1) in the radical prostatectomy specimen the correlation of microscopic extracapsular extension with pathological cancer volume, pathological tumor contact length and Gleason score, 2) the correlation between microscopic extracapsular extension and magnetic resonance imaging tumor contact length, and 3) the ability of preoperative variables to predict microscopic extracapsular extension. Logistic regression analysis revealed that pathological tumor contact length correlated better with microscopic extracapsular extension than the predictive power of pathological cancer volume (0.821 vs 0.685). The Spearman correlation between pathological and magnetic resonance imaging tumor contact length was r = 0.839 (p <0.0001). ROC AUC analysis revealed that magnetic resonance imaging tumor contact length outperformed cancer core involvement on targeted biopsy and the Partin tables to predict microscopic extracapsular extension (0.88 vs 0.70 and 0.63, respectively). At a magnetic resonance imaging tumor contact length threshold of 20 mm the accuracy for diagnosing microscopic extracapsular extension was superior to that of conventional magnetic resonance imaging criteria (82% vs 67%, p = 0.015). We developed a predicted probability plot curve of extracapsular extension according to magnetic resonance imaging tumor contact length. Magnetic resonance imaging determined tumor contact length could be a promising quantitative predictor of microscopic extracapsular extension. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a significantly higher percent of cancer involvement per biopsy core. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Magnetic Resonance Imaging Targeted Biopsy Improves Selection of Patients Considered for Active Surveillance for Clinically Low Risk Prostate Cancer Based on Systematic Biopsies.

    PubMed

    Ouzzane, Adil; Renard-Penna, Raphaele; Marliere, François; Mozer, Pierre; Olivier, Jonathan; Barkatz, Johann; Puech, Philippe; Villers, Arnauld

    2015-08-01

    Current selection criteria for active surveillance based on systematic biopsy underestimate prostate cancer volume and grade. We investigated the role of additional magnetic resonance imaging targeted biopsy in reclassifying patients eligible for active surveillance based on systematic biopsy. We performed a study at 2 institutions in a total of 281 men with increased prostate specific antigen. All men met certain criteria, including 1) prebiopsy magnetic resonance imaging, 12-core transrectal systematic biopsy and 2 additional magnetic resonance imaging targeted biopsies of lesions suspicious for cancer during the same sequence as systematic biopsy, and 2) eligibility for active surveillance based on systematic biopsy results. Criteria for active surveillance were prostate specific antigen less than 10 ng/ml, no Gleason grade 4/5, 5 mm or less involvement of any biopsy core and 2 or fewer positive systematic biopsy cores. Patient characteristics were compared between reclassified and nonreclassified groups based on magnetic resonance imaging targeted biopsy results. On magnetic resonance imaging 58% of the 281 patients had suspicious lesions. Magnetic resonance imaging targeted biopsy was positive for cancer in 81 of 163 patients (50%). Of 281 patients 28 (10%) were reclassified by magnetic resonance imaging targeted biopsy as ineligible for active surveillance based on Gleason score in 8, cancer length in 20 and Gleason score plus cancer length in 9. Suspicious areas on magnetic resonance imaging were in the anterior part of the prostate in 15 of the 28 men (54%). Reclassified patients had a smaller prostate volume (37 vs 52 cc) and were older (66.5 vs 63 years) than those who were not reclassified (p < 0.05). Magnetic resonance imaging targeted biopsy reclassified 10% of patients who were eligible for active surveillance based on systematic biopsy. Its incorporation into the active surveillance eligibility criteria may decrease the risk of reclassification to higher stages during followup. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Magnetic resonance imaging of the fetal brain.

    PubMed

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  12. Determination of Location, Size and Transmurality of Chronic Myocardial Infarction Without Exogenous Contrast Media Using Cardiac Magnetic Resonance Imaging at 3T

    PubMed Central

    Kali, Avinash; Cokic, Ivan; Tang, Richard L Q; Yang, Hsin-Jung; Sharif, Behzad; Marbán, Eduardo; Li, Debiao; Berman, Daniel; Dharmakumar, Rohan

    2014-01-01

    Background LGE CMR is a powerful method for characterizing MI, but the requisite gadolinium infusion is estimated to be contraindicated in nearly 20% of MI patients due to end-stage chronic kidney disease. The purpose of this study is to investigate whether T1 Cardiovascular-Magnetic-Resonance Imaging (CMR) obtained without contrast agents at 3T could be an alternative to Late-Gadolinium-Enhanced (LGE) CMR for characterizing chronic myocardial infarctions (MIs) using a canine model of MI. Methods and Results Canines (n=29) underwent CMR at 7 days (acute, AMI) and 4 months (chronic, CMI) post-MI. Infarct location, size and transmurality measured using native T1 maps and LGE images at 1.5T and 3T were compared. Resolution of edema between AMI and CMI was examined with T2 maps. T1 maps overestimated infarct size and transmurality relative to LGE images in AMI (p=0.016 and p=0.007, respectively), which was not observed in CMI (p=0.49 and p=0.81, respectively), at 3T. T1 maps underestimated infarct size and transmurality relative to LGE images in AMI and CMI (p<0.001), at 1.5T. Relative to the remote territories, T1 of the infarcted myocardium was increased in CMI and AMI (p<0.05); and T2 of the infarcted myocardium was increased in AMI (p<0.001), but not in CMI (p >0.20) at both field strengths. Histology showed extensive replacement fibrosis within the CMI territories. CMI detection sensitivity and specificity of T1 CMR at 3T were 95% and 97%, respectively. Conclusions Native T1 maps at 3T can determine the location, size and transmurality of CMI with high diagnostic accuracy. Patient studies are necessary for clinical translation. PMID:24682268

  13. Magnetic resonance appearance of monoclonal gammopathies of unknown significance and multiple myeloma. The GRI Study Group.

    PubMed

    Bellaïche, L; Laredo, J D; Lioté, F; Koeger, A C; Hamze, B; Ziza, J M; Pertuiset, E; Bardin, T; Tubiana, J M

    1997-11-01

    A prospective multicenter study. To evaluate the use of magnetic resonance imaging, in the differentiation between monoclonal gammopathies of unknown significance and multiple myeloma. Although multiple myeloma has been studied extensively with magnetic resonance imaging, to the authors' knowledge, no study has evaluated the clinical interest of magnetic resonance imaging in the differentiation between monoclonal gammopathies of unknown significance and multiple myeloma. The magnetic resonance examinations of the thoracolumbar spine in 24 patients with newly diagnosed monoclonal gammopathies of unknown significance were compared with those performed in 44 patients with newly diagnosed nontreated multiple myeloma. All findings on magnetic resonance examination performed in patients with monoclonal gammopathies of unknown significance were normal, whereas findings on 38 (86%) of the 44 magnetic resonance examinations performed in patients with multiple myeloma were abnormal. Magnetic resonance imaging can be considered as an additional diagnostic tool in differentiating between monoclonal gammopathies of unknown significance and multiple myeloma, which may be helpful when routine criteria are not sufficient. An abnormal finding on magnetic resonance examination in a patient with monoclonal gammopathies of unknown significance should suggest the diagnosis of multiple myeloma after other causes of marrow signal abnormalities are excluded. Magnetic resonance imaging also may be proposed in the long-term follow-up of monoclonal gammopathies of unknown significance when a new biologic or clinical event suggests the diagnosis of malignant monoclonal gammopathy.

  14. Imaging agents for in vivo magnetic resonance and scintigraphic imaging

    DOEpatents

    Engelstad, B.L.; Raymond, K.N.; Huberty, J.P.; White, D.L.

    1991-04-23

    Methods are provided for in vivo magnetic resonance imaging and/or scintigraphic imaging of a subject using chelated transition metal and lanthanide metal complexes. Novel ligands for these complexes are provided. No Drawings

  15. Multi circular-cavity surface coil for magnetic resonance imaging of monkey's brain at 4 Tesla

    NASA Astrophysics Data System (ADS)

    Osorio, A. I.; Solis-Najera, S. E.; Vázquez, F.; Wang, R. L.; Tomasi, D.; Rodriguez, A. O.

    2014-11-01

    Animal models in medical research has been used to study humans diseases for several decades. The use of different imaging techniques together with different animal models offers a great advantage due to the possibility to study some human pathologies without the necessity of chirurgical intervention. The employ of magnetic resonance imaging for the acquisition of anatomical and functional images is an excellent tool because its noninvasive nature. Dedicated coils to perform magnetic resonance imaging experiments are obligatory due to the improvement on the signal-to-noise ratio and reduced specific absorption ratio. A specifically designed surface coil for magnetic resonance imaging of monkey's brain is proposed based on the multi circular-slot coil. Numerical simulations of the magnetic and electric fields were also performed using the Finite Integration Method to solve Maxwell's equations for this particular coil design and, to study the behavior of various vector magnetic field configurations and specific absorption ratio. Monkey's brain images were then acquired with a research-dedicated magnetic resonance imaging system at 4T, to evaluate the anatomical images with conventional imaging sequences. This coil showed good quality images of a monkey's brain and full compatibility with standard pulse sequences implemented in research-dedicated imager.

  16. Quantitative magnetic resonance micro-imaging methods for pharmaceutical research.

    PubMed

    Mantle, M D

    2011-09-30

    The use of magnetic resonance imaging (MRI) as a tool in pharmaceutical research is now well established and the current literature covers a multitude of different pharmaceutically relevant research areas. This review focuses on the use of quantitative magnetic resonance micro-imaging techniques and how they have been exploited to extract information that is of direct relevance to the pharmaceutical industry. The article is divided into two main areas. The first half outlines the theoretical aspects of magnetic resonance and deals with basic magnetic resonance theory, the effects of nuclear spin-lattice (T(1)), spin-spin (T(2)) relaxation and molecular diffusion upon image quantitation, and discusses the applications of rapid magnetic resonance imaging techniques. In addition to the theory, the review aims to provide some practical guidelines for the pharmaceutical researcher with an interest in MRI as to which MRI pulse sequences/protocols should be used and when. The second half of the article reviews the recent advances and developments that have appeared in the literature concerning the use of quantitative micro-imaging methods to pharmaceutically relevant research. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Diagnosis of Nipple Discharge: Value of Magnetic Resonance Imaging and Ultrasonography in Comparison with Ductoscopy.

    PubMed

    Yılmaz, Ravza; Bender, Ömer; Çelik Yabul, Fatma; Dursun, Menduh; Tunacı, Mehtap; Acunas, Gülden

    2017-04-05

    Pathologic nipple discharge, which is a common reason for referral to the breast imaging service, refers to spontaneous or bloody nipple discharge that arises from a single duct. The most common cause of nipple discharge is benign breast lesions, such as solitary intraductal papilloma and papillomatosis. Nevertheless, in rare cases, a malignant cause of nipple discharge can be found. To study the diagnostic value of ultrasonography, magnetic resonance imaging, and ductoscopy in patients with pathologic nipple discharge, compare their efficacy, and investigate the importance of magnetic resonance imaging in the diagnosis of intraductal pathologies. Diagnostic accuracy study. Fifty patients with pathologic nipple discharge were evaluated by ultrasonography and magnetic resonance imaging. Of these, 44 ductoscopic investigations were made. The patients were classified according to magnetic resonance imaging, ultrasonography, and ductoscopy findings. A total of 25 patients, whose findings were reported as intraductal masses, underwent surgery oincluding endoscopic excision for two endoscopic excision. Findings were compared with the pathology results that were accepted as the gold standard in the description of the aetiology of nipple discharge. In addition, magnetic resonance imaging, ultrasonography and ductoscopy findings were analysed comparatively in patients who had no surgery. Intraductal masses were reported in 26 patients, 20 of whom operated and established accurate diagnosis of 18 patients on magnetic resonance imaging. According to the ultrasonography, intraductal masses were identified in 22 patients, 17 of whom underwent surgery. Ultrasonography established accurate diagnoses in 15 patients. Intraductal mass was identified in 22 patients and ductoscopy established accurate diagnoses based on histopathologic results in 16 patients. The sensitivities of methods were 75% in ultrasonography, 90% in magnetic resonance imaging, and 94.6% in ductoscopy. The specificities were 66.7% in ultrasonography, 66.7% in magnetic resonance imaging, and 40% in ductoscopy. Intraductal papillomas were mostly observed as oval nodules with well-circumscribed smooth margins within dilated ducts and persistant in the dynamic analysis. Lesions that protruded into the lumen of the ducts, either solitary or multiple, were characteristic ductoscopy findings of our patients who were diagnosed as having papilloma/papillomatosis. Magnetic resonance imaging and ductoscopy had no statistical superiority over each other, however they were superior to ultrasonography in the diagnosis of pathologic nipple discharge. Magnetic resonance imaging may be highly sensitive for diagnosing nipple discharge with new techniques and sequences and a non-invasive method that more advantageous for showing ductal tree visualization and is able to detect completely obstructed intraductal lesions.

  18. A Single Center Evaluation of the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging against Transperineal Prostate Mapping Biopsy: An Analysis of Men with Benign Histology and Insignificant Cancer following Transrectal Ultrasound Biopsy.

    PubMed

    Pal, Raj P; Ahmad, Ros; Trecartan, Shaun; Voss, James; Ahmed, Shaista; Bazo, Alvaro; Lloyd, Jon; Walton, Thomas J

    2018-03-01

    In this study we evaluated the diagnostic performance of transrectal ultrasound guided biopsy and multiparametric magnetic resonance imaging to detect prostate cancer against transperineal prostate mapping biopsy as the reference test. Transrectal ultrasound guided biopsy, multiparametric magnetic resonance imaging and transperineal prostate mapping biopsy were performed in 426 patients between April 2012 and January 2016. Patients initially underwent systematic 12 core transrectal ultrasound guided biopsy followed 3 months later by 1.5 Tesla, high resolution T2, diffusion-weighted, dynamic contrast enhanced multiparametric magnetic resonance imaging. Two specialist uroradiologists blinded to the results of transperineal prostate mapping biopsy allocated a PI-RADS™ (Prostate Imaging-Reporting and Data System) score to each multiparametric magnetic resonance imaging study. Transperineal prostate mapping biopsy with 5 mm interval sampling, which was performed within 6 months of multiparametric magnetic resonance imaging, served as the reference test. Transrectal ultrasound guided biopsy identified 247 of 426 patients with prostate cancer and 179 of 426 with benign histology. Transperineal prostate mapping biopsy detected prostate cancer in 321 of 426 patients. On transperineal prostate mapping biopsy 94 of 179 patients with benign transrectal ultrasound guided biopsy had prostate cancer and 95 of 247 with prostate cancer on transrectal ultrasound guided biopsy were identified with cancer of higher grade. Using a multiparametric magnetic resonance imaging PI-RADS score of 3 or greater to detect significant prostate cancer, defined as any core containing Gleason 4 + 3 or greater prostate cancer on transperineal prostate mapping biopsy, the ROC AUC was 0.754 (95% CI 0.677-0.819) with 87.0% sensitivity (95% CI 77.3-97.0), 55.3% specificity (95% CI 50.2-60.4) and 97.1% negative predictive value (95% CI 94.8-99.4). Multiparametric magnetic resonance imaging is a more accurate diagnostic test than transrectal ultrasound guided biopsy. However, a significant proportion of ISUP (International Society of Urological Pathology) Grade Group 2 prostate cancer remained undetected following multiparametric magnetic resonance imaging. Although multiparametric magnetic resonance imaging could avoid unnecessary biopsy in many patients with ISUP Grade Group 3 or greater prostate cancer, at less stringent definitions of significant cancer a substantial proportion of prostate cancer would remain undetected after multiparametric magnetic resonance imaging. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    PubMed

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  20. Regularized Reconstruction of Dynamic Contrast-Enhanced MR Images for Evaluation of Breast Lesions

    DTIC Science & Technology

    2010-09-01

    resonance imaging . We focus specifically on dynamic contrast-enhanced (DCE) imaging of breast cancer patients. The fundamental challenge in dynamic MRI is...Venkatesan, Magnetic resonance imaging : Physical principles and sequence design, Wiley, New York, 1999. 14 [7] P. S. Tofts and A. G. Kermode, “Measurement...10, no. 3, pp. 223–32, Sept. 1999. [12] D. C. Noll, D. G. Nishimura, and A. Macovski, “Homodyne detection in magnetic resonance imaging ,” IEEE Trans

  1. Serial Magnetic Resonance Imaging in Active Surveillance of Prostate Cancer: Incremental Value.

    PubMed

    Felker, Ely R; Wu, Jason; Natarajan, Shyam; Margolis, Daniel J; Raman, Steven S; Huang, Jiaoti; Dorey, Fred; Marks, Leonard S

    2016-05-01

    We assessed whether changes in serial multiparametric magnetic resonance imaging can help predict the pathological progression of prostate cancer in men on active surveillance. A retrospective cohort study was conducted of 49 consecutive men with Gleason 6 prostate cancer who underwent multiparametric magnetic resonance imaging at baseline and again more than 6 months later, each followed by a targeted prostate biopsy, between January 2011 and May 2015. We evaluated whether progression on multiparametric magnetic resonance imaging (an increase in index lesion suspicion score, increase in index lesion volume or decrease in index lesion apparent diffusion coefficient) could predict pathological progression (Gleason 3 + 4 or greater on subsequent biopsy, in systematic or targeted cores). Diagnostic performance of multiparametric magnetic resonance imaging was determined with and without clinical data using a binary logistic regression model. The mean interval between baseline and followup multiparametric magnetic resonance imaging was 28.3 months (range 11 to 43). Pathological progression occurred in 19 patients (39%). The sensitivity, specificity, positive predictive value and negative predictive value of multiparametric magnetic resonance imaging was 37%, 90%, 69% and 70%, respectively. Area under the receiver operating characteristic curve was 0.63. A logistic regression model using clinical information (maximum cancer core length greater than 3 mm on baseline biopsy or a prostate specific antigen density greater than 0.15 ng/ml(2) at followup biopsy) had an AUC of 0.87 for predicting pathological progression. The addition of serial multiparametric magnetic resonance imaging data significantly improved the AUC to 0.91 (p=0.044). Serial multiparametric magnetic resonance imaging adds incremental value to prostate specific antigen density and baseline cancer core length for predicting Gleason 6 upgrading in men on active surveillance. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Computed tomography and magnetic resonance imaging findings of intraorbital granular cell tumor (Abrikossoff's tumor): a case report.

    PubMed

    Yuan, Wei-Hsin; Lin, Tai-Chi; Lirng, Jiing-Feng; Guo, Wan-You; Chang, Fu-Pang; Ho, Donald Ming-Tak

    2016-05-13

    Granular cell tumors are rare neoplasms which can occur in any part of the body. Granular cell tumors of the orbit account for only 3 % of all granular cell tumor cases. Computed tomography and magnetic resonance imaging of the orbit have proven useful for diagnosing orbital tumors. However, the rarity of intraorbital granular cell tumors poses a significant diagnostic challenge for both clinicians and radiologists. We report a case of a 37-year-old Chinese woman with a rare intraocular granular cell tumor of her right eye presenting with diplopia, proptosis, and restriction of ocular movement. Preoperative orbital computed tomography and magnetic resonance imaging with contrast enhancement revealed an enhancing solid, ovoid, well-demarcated, retrobulbar nodule. In addition, magnetic resonance imaging features included an intraorbital tumor which was isointense relative to gray matter on T1-weighted imaging and hypointense on T2-weighted imaging. No diffusion restriction of water was noted on either axial diffusion-weighted images or apparent diffusion coefficient maps. Both computed tomography and magnetic resonance imaging features suggested an intraorbital hemangioma. However, postoperative pathology (together with immunohistochemistry) identified an intraorbital granular cell tumor. When intraorbital T2 hypointensity and free diffusion of water are observed on magnetic resonance imaging, a granular cell tumor should be included in the differential diagnosis of an intraocular tumor.

  3. Contributions of structural connectivity and cerebrovascular parameters to functional magnetic resonance imaging signals in mice at rest and during sensory paw stimulation.

    PubMed

    Schroeter, Aileen; Grandjean, Joanes; Schlegel, Felix; Saab, Bechara J; Rudin, Markus

    2017-07-01

    Previously, we reported widespread bilateral increases in stimulus-evoked functional magnetic resonance imaging signals in mouse brain to unilateral sensory paw stimulation. We attributed the pattern to arousal-related cardiovascular changes overruling cerebral autoregulation thereby masking specific signal changes elicited by local neuronal activity. To rule out the possibility that interhemispheric neuronal communication might contribute to bilateral functional magnetic resonance imaging responses, we compared stimulus-evoked functional magnetic resonance imaging responses to unilateral hindpaw stimulation in acallosal I/LnJ, C57BL/6, and BALB/c mice. We found bilateral blood-oxygenation-level dependent signal changes in all three strains, ruling out a dominant contribution of transcallosal communication as reason for bilaterality. Analysis of functional connectivity derived from resting-state functional magnetic resonance imaging, revealed that bilateral cortical functional connectivity is largely abolished in I/LnJ animals. Cortical functional connectivity in all strains correlated with structural connectivity in corpus callosum as revealed by diffusion tensor imaging. Given the profound influence of systemic hemodynamics on stimulus-evoked functional magnetic resonance imaging outcomes, we evaluated whether functional connectivity data might be affected by cerebrovascular parameters, i.e. baseline cerebral blood volume, vascular reactivity, and reserve. We found that effects of cerebral hemodynamics on functional connectivity are largely outweighed by dominating contributions of structural connectivity. In contrast, contributions of transcallosal interhemispheric communication to the occurrence of ipsilateral functional magnetic resonance imaging response of equal amplitude to unilateral stimuli seem negligible.

  4. Tracking iron in multiple sclerosis: a combined imaging and histopathological study at 7 Tesla

    PubMed Central

    Hametner, Simon; Yao, Bing; van Gelderen, Peter; Merkle, Hellmut; Cantor, Fredric K.; Lassmann, Hans; Duyn, Jeff H.

    2011-01-01

    Previous authors have shown that the transverse relaxivity R2* and frequency shifts that characterize gradient echo signal decay in magnetic resonance imaging are closely associated with the distribution of iron and myelin in the brain's white matter. In multiple sclerosis, iron accumulation in brain tissue may reflect a multiplicity of pathological processes. Hence, iron may have the unique potential to serve as an in vivo magnetic resonance imaging tracer of disease pathology. To investigate the ability of iron in tracking multiple sclerosis-induced pathology by magnetic resonance imaging, we performed qualitative histopathological analysis of white matter lesions and normal-appearing white matter regions with variable appearance on gradient echo magnetic resonance imaging at 7 Tesla. The samples used for this study derive from two patients with multiple sclerosis and one non-multiple sclerosis donor. Magnetic resonance images were acquired using a whole body 7 Tesla magnetic resonance imaging scanner equipped with a 24-channel receive-only array designed for tissue imaging. A 3D multi-gradient echo sequence was obtained and quantitative R2* and phase maps were reconstructed. Immunohistochemical stainings for myelin and oligodendrocytes, microglia and macrophages, ferritin and ferritin light polypeptide were performed on 3- to 5-µm thick paraffin sections. Iron was detected with Perl's staining and 3,3′-diaminobenzidine-tetrahydrochloride enhanced Turnbull blue staining. In multiple sclerosis tissue, iron presence invariably matched with an increase in R2*. Conversely, R2* increase was not always associated with the presence of iron on histochemical staining. We interpret this finding as the effect of embedding, sectioning and staining procedures. These processes likely affected the histopathological analysis results but not the magnetic resonance imaging that was obtained before tissue manipulations. Several cellular sources of iron were identified. These sources included oligodendrocytes in normal-appearing white matter and activated macrophages/microglia at the edges of white matter lesions. Additionally, in white matter lesions, iron precipitation in aggregates typical of microbleeds was shown by the Perl's staining. Our combined imaging and pathological study shows that multi-gradient echo magnetic resonance imaging is a sensitive technique for the identification of iron in the brain tissue of patients with multiple sclerosis. However, magnetic resonance imaging-identified iron does not necessarily reflect pathology and may also be seen in apparently normal tissue. Iron identification by multi-gradient echo magnetic resonance imaging in diseased tissues can shed light on the pathological processes when coupled with topographical information and patient disease history. PMID:22171355

  5. Soft tissue examination of the fetal rat and rabbit head by magnetic resonance imaging.

    PubMed

    French, Julian M; Woodhouse, Neil

    2013-01-01

    The use of magnetic resonance imaging of the fetal rat and rabbit head, as an alternative to the traditional methods of fixation and preparation of serial sections, is described. Labeled magnetic resonance images of normal head anatomy have been provided as a reference for use when evaluating the internal structures of the head.

  6. Leukoencephalopathy with thalamus and brainstem involvement and high lactate 'LTBL' caused by EARS2 mutations.

    PubMed

    Steenweg, Marjan E; Ghezzi, Daniele; Haack, Tobias; Abbink, Truus E M; Martinelli, Diego; van Berkel, Carola G M; Bley, Annette; Diogo, Luisa; Grillo, Eugenio; Te Water Naudé, Johann; Strom, Tim M; Bertini, Enrico; Prokisch, Holger; van der Knaap, Marjo S; Zeviani, Massimo

    2012-05-01

    In the large group of genetically undetermined infantile-onset mitochondrial encephalopathies, multiple defects of mitochondrial DNA-related respiratory-chain complexes constitute a frequent biochemical signature. In order to identify responsible genes, we used exome-next-generation sequencing in a selected cohort of patients with this biochemical signature. In an isolated patient, we found two mutant alleles for EARS2, the gene encoding mitochondrial glutamyl-tRNA synthetase. The brain magnetic resonance imaging of this patient was hallmarked by extensive symmetrical cerebral white matter abnormalities sparing the periventricular rim and symmetrical signal abnormalities of the thalami, midbrain, pons, medulla oblongata and cerebellar white matter. Proton magnetic resonance spectroscopy showed increased lactate. We matched this magnetic resonance imaging pattern with that of a cohort of 11 previously selected unrelated cases. We found mutations in the EARS2 gene in all. Subsequent detailed clinical and magnetic resonance imaging based phenotyping revealed two distinct groups: mild and severe. All 12 patients shared an infantile onset and rapidly progressive disease with severe magnetic resonance imaging abnormalities and increased lactate in body fluids and proton magnetic resonance spectroscopy. Patients in the 'mild' group partially recovered and regained milestones in the following years with striking magnetic resonance imaging improvement and declining lactate levels, whereas those of the 'severe' group were characterized by clinical stagnation, brain atrophy on magnetic resonance imaging and persistent lactate increases. This new neurological disease, early-onset leukoencephalopathy with thalamus and brainstem involvement and high lactate, is hallmarked by unique magnetic resonance imaging features, defined by a peculiar biphasic clinical course and caused by mutations in a single gene, EARS2, expanding the list of medically relevant defects of mitochondrial DNA translation.

  7. Silicon Nanoparticles as Hyperpolarized Magnetic Resonance Imaging Agents

    PubMed Central

    Aptekar, Jacob W.; Cassidy, Maja C.; Johnson, Alexander C.; Barton, Robert A.; Lee, Menyoung; Ogier, Alexander C.; Vo, Chinh; Anahtar, Melis N.; Ren, Yin; Bhatia, Sangeeta N.; Ramanathan, Chandrasekhar; Cory, David G.; Hill, Alison L.; Mair, Ross W.; Rosen, Matthew S.; Walsworth, Ronald L.

    2014-01-01

    Magnetic resonance imaging of hyperpolarized nuclei provides high image contrast with little or no background signal. To date, in-vivo applications of pre-hyperpolarized materials have been limited by relatively short nuclear spin relaxation times. Here, we investigate silicon nanoparticles as a new type of hyperpolarized magnetic resonance imaging agent. Nuclear spin relaxation times for a variety of Si nanoparticles are found to be remarkably long, ranging from many minutes to hours at room temperature, allowing hyperpolarized nanoparticles to be transported, administered, and imaged on practical time scales. Additionally, we demonstrate that Si nanoparticles can be surface functionalized using techniques common to other biologically targeted nanoparticle systems. These results suggest that Si nanoparticles can be used as a targetable, hyperpolarized magnetic resonance imaging agent with a large range of potential applications. PMID:19950973

  8. Silicon nanoparticles as hyperpolarized magnetic resonance imaging agents.

    PubMed

    Aptekar, Jacob W; Cassidy, Maja C; Johnson, Alexander C; Barton, Robert A; Lee, Menyoung; Ogier, Alexander C; Vo, Chinh; Anahtar, Melis N; Ren, Yin; Bhatia, Sangeeta N; Ramanathan, Chandrasekhar; Cory, David G; Hill, Alison L; Mair, Ross W; Rosen, Matthew S; Walsworth, Ronald L; Marcus, Charles M

    2009-12-22

    Magnetic resonance imaging of hyperpolarized nuclei provides high image contrast with little or no background signal. To date, in vivo applications of prehyperpolarized materials have been limited by relatively short nuclear spin relaxation times. Here, we investigate silicon nanoparticles as a new type of hyperpolarized magnetic resonance imaging agent. Nuclear spin relaxation times for a variety of Si nanoparticles are found to be remarkably long, ranging from many minutes to hours at room temperature, allowing hyperpolarized nanoparticles to be transported, administered, and imaged on practical time scales. Additionally, we demonstrate that Si nanoparticles can be surface functionalized using techniques common to other biologically targeted nanoparticle systems. These results suggest that Si nanoparticles can be used as a targetable, hyperpolarized magnetic resonance imaging agent with a large range of potential applications.

  9. Breast cancer screening and problem solving using mammography, ultrasound, and magnetic resonance imaging.

    PubMed

    Hooley, Regina J; Andrejeva, Liva; Scoutt, Leslie M

    2011-03-01

    Although mammography is the mainstay of early breast cancer detection, it has known limitations, particularly in women with dense breasts. As a result, additional imaging modalities, including ultrasound and contrast-enhanced magnetic resonance imaging, are also being used to supplement mammography in the early detection of occult breast cancer. This article reviews the indications and efficacy of mammography, ultrasound, and magnetic resonance imaging as both screening and diagnostic tools.

  10. Assessment of mitral regurgitation in dogs: comparison of results of echocardiography with magnetic resonance imaging.

    PubMed

    Sargent, J; Connolly, D J; Watts, V; Mõtsküla, P; Volk, H A; Lamb, C R; Fuentes, V Luis

    2015-11-01

    Echocardiography is used routinely to assess mitral regurgitation severity, but echocardiographic measures of mitral regurgitation in dogs have not been compared with other quantitative methods. The study aim was to compare echocardiographic measures of mitral regurgitation with cardiac magnetic resonance imaging-derived mitral regurgitant fraction in small-breed dogs. Dogs with myxomatous mitral valve disease scheduled for magnetic resonance imaging assessment of neurological disease were recruited. Correlations were tested between cardiac magnetic resonance imaging-derived mitral regurgitant fraction and the following echocardiographic measures: vena contracta/aortic diameter, transmitral E-wave velocity, amplitude of mitral prolapse/aortic diameter, diastolic left ventricular diameter:aortic diameter, left atrium:aortic diameter, mitral regurgitation jet area ratio and regurgitant fraction calculated using the proximal isovelocity surface area method. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction was attempted in 21 dogs. Twelve consecutive, complete studies were obtained and 10 dogs were included in the final analysis: vena contracta/aortic diameter (r = 0 · 89, p = 0 · 001) and E-wave velocity (r = 0 · 86, p = 0 · 001) had the strongest correlations with cardiac magnetic resonance imaging-derived mitral regurgitant fraction. E velocity had superior repeatability and could be measured in all dogs. The presence of multiple jets precluded vena contracta/aortic diameter measurement in one dog. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction is feasible but technically demanding. The echocardiographic measures that correlated most closely with cardiac magnetic resonance imaging-derived mitral regurgitant fraction were vena contracta/aortic diameter and E-wave velocity. © 2015 British Small Animal Veterinary Association.

  11. Clinical implications of a multiparametric magnetic resonance imaging based nomogram applied to prostate cancer active surveillance.

    PubMed

    Siddiqui, M Minhaj; Truong, Hong; Rais-Bahrami, Soroush; Stamatakis, Lambros; Logan, Jennifer; Walton-Diaz, Annerleim; Turkbey, Baris; Choyke, Peter L; Wood, Bradford J; Simon, Richard M; Pinto, Peter A

    2015-06-01

    Multiparametric magnetic resonance imaging may be beneficial in the search for rational ways to decrease prostate cancer intervention in patients on active surveillance. We applied a previously generated nomogram based on multiparametric magnetic resonance imaging to predict active surveillance eligibility based on repeat biopsy outcomes. We reviewed the records of 85 patients who met active surveillance criteria at study entry based on initial biopsy and who then underwent 3.0 Tesla multiparametric magnetic resonance imaging with subsequent magnetic resonance imaging/ultrasound fusion guided prostate biopsy between 2007 and 2012. We assessed the accuracy of a previously published nomogram in patients on active surveillance before confirmatory biopsy. For each cutoff we determined the number of biopsies avoided (ie reliance on magnetic resonance imaging alone without rebiopsy) over the full range of nomogram cutoffs. We assessed the performance of the multiparametric magnetic resonance imaging active surveillance nomogram based on a decision to perform biopsy at various nomogram generated probabilities. Based on cutoff probabilities of 19% to 32% on the nomogram the number of patients who could be spared repeat biopsy was 27% to 68% of the active surveillance cohort. The sensitivity of the test in this interval was 97% to 71% and negative predictive value was 91% to 81%. Multiparametric magnetic resonance imaging based nomograms may reasonably decrease the number of repeat biopsies in patients on active surveillance by as much as 68%. Analysis over the full range of nomogram generated probabilities allows patient and caregiver preference based decision making on the risk assumed for the benefit of fewer repeat biopsies. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. An alternative way to increase the power gain of resonant rings

    NASA Astrophysics Data System (ADS)

    Zhuang, Dehao; Liu, Yunqi; Wang, Fang; Lin, Lin; Feng, Liwen; Quan, Shengwen; Liu, Kexin

    2018-03-01

    Resonant rings which can amplify RF power through the coupling of waves are used for high power breakdown tests, unidirectional filters, or pulse-shaping techniques. Usually, the RF output terminal of a resonant ring is connected to a matched load. For the resonant ring at Peking University, the matched load has been replaced by a waveguide shorting plate to obtain higher conditioning power for the 1.3 GHz capacitive type power couplers. The power gain is increased significantly with this short termination with the same input RF power. Working mechanism analysis, experiments, and results of this modified resonant ring will be presented.

  13. Artifacts Affecting Musculoskeletal Magnetic Resonance Imaging: Their Origins and Solutions.

    PubMed

    Roth, Eira; Hoff, Michael; Richardson, Michael L; Ha, Alice S; Porrino, Jack

    2016-01-01

    Among articles within the radiology literature, few present the manifestations of magnetic resonance imaging artifacts in a clinically oriented manner. Recognizing such artifacts is imperative given the increasing clinical use of magnetic resonance imaging and the emphasis by the American Board of Radiology on practical physics applications. The purpose of this article is to present magnetic resonance physics principles visually and conceptually in the context of common musculoskeletal radiology artifacts and their solutions, described using nonmathematical explanations. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Brain Lesions

    MedlinePlus

    ... seen on a brain-imaging test, such as magnetic resonance imaging (MRI) or computerized tomography (CT). On ... A cohort study. PLOS One. 2013;8:e71467. Magnetic resonance imaging (MRI). National Multiple Sclerosis Society. http:// ...

  15. Dental materials and magnetic resonance imaging.

    PubMed

    Hubálková, Hana; Hora, Karel; Seidl, Zdenek; Krásenský, Jan

    2002-09-01

    The objective of this investigation was to evaluate the reaction of selected dental materials in the magnetic field of a magnetic resonance imaging device to determine a possible health risk. The following dental materials were tested in vitro during magnetic resonance imaging: 15 dental alloys, four dental implants, one surgical splint and two wires for fixation of maxillofacial fractures. Possible artefacts (corresponding with magnetic properties), heating and force effects were tested. Results concerning movement and heating were in agreement with the literature. The artefacts seen were significant: for the surgical splint, a spherical artefact with a diameter of 55 mm; for the wires, up to 22 mm; and for the dental blade implant, an artefact of 28 x 20 mm. The results of our tests of selected dental appliances indicate that their presence in the human organism is safe for patients undergoing magnetic resonance imaging procedures. The presence of artefacts can substantially influence the magnetic resonance imaging results.

  16. One-pot synthesis of magnetic nanoclusters enabling atherosclerosis-targeted magnetic resonance imaging.

    PubMed

    Kukreja, Aastha; Lim, Eun-Kyung; Kang, Byunghoon; Choi, Yuna; Lee, Taeksu; Suh, Jin-Suck; Huh, Yong-Min; Haam, Seungjoo

    2014-01-01

    In this study, dextran-encrusted magnetic nanoclusters (DMNCs) were synthesized using a one-pot solution phase method for detection of atherosclerosis by magnetic resonance imaging. Pyrenyl dextran was used as a surfactant because of its electron-stabilizing effect and its amphiphilic nature, rendering the DMNCs stable and water-dispersible. The DMNCs were 65.6±4.3 nm, had a narrow size distribution, and were superparamagnetic with a high magnetization value of 60.1 emu/g. Further, they showed biocompatibility and high cellular uptake efficiency, as indicated by a strong interaction between dextran and macrophages. In vivo magnetic resonance imaging demonstrated the ability of DMNCs to act as an efficient magnetic resonance imaging contrast agent capable of targeted detection of atherosclerosis. In view of these findings, it is concluded that DMNCs can be used as magnetic resonance imaging contrast agents to detect inflammatory disease.

  17. Imaging in anatomy: a comparison of imaging techniques in embalmed human cadavers

    PubMed Central

    2013-01-01

    Background A large variety of imaging techniques is an integral part of modern medicine. Introducing radiological imaging techniques into the dissection course serves as a basis for improved learning of anatomy and multidisciplinary learning in pre-clinical medical education. Methods Four different imaging techniques (ultrasound, radiography, computed tomography, and magnetic resonance imaging) were performed in embalmed human body donors to analyse possibilities and limitations of the respective techniques in this peculiar setting. Results The quality of ultrasound and radiography images was poor, images of computed tomography and magnetic resonance imaging were of good quality. Conclusion Computed tomography and magnetic resonance imaging have a superior image quality in comparison to ultrasound and radiography and offer suitable methods for imaging embalmed human cadavers as a valuable addition to the dissection course. PMID:24156510

  18. Positive effect on patient experience of video information given prior to cardiovascular magnetic resonance imaging: A clinical trial.

    PubMed

    Ahlander, Britt-Marie; Engvall, Jan; Maret, Eva; Ericsson, Elisabeth

    2018-03-01

    To evaluate the effect of video information given before cardiovascular magnetic resonance imaging on patient anxiety and to compare patient experiences of cardiovascular magnetic resonance imaging versus myocardial perfusion scintigraphy. To evaluate whether additional information has an impact on motion artefacts. Cardiovascular magnetic resonance imaging and myocardial perfusion scintigraphy are technically advanced methods for the evaluation of heart diseases. Although cardiovascular magnetic resonance imaging is considered to be painless, patients may experience anxiety due to the closed environment. A prospective randomised intervention study, not registered. The sample (n = 148) consisted of 97 patients referred for cardiovascular magnetic resonance imaging, randomised to receive either video information in addition to standard text-information (CMR-video/n = 49) or standard text-information alone (CMR-standard/n = 48). A third group undergoing myocardial perfusion scintigraphy (n = 51) was compared with the cardiovascular magnetic resonance imaging-standard group. Anxiety was evaluated before, immediately after the procedure and 1 week later. Five questionnaires were used: Cardiac Anxiety Questionnaire, State-Trait Anxiety Inventory, Hospital Anxiety and Depression scale, MRI Fear Survey Schedule and the MRI-Anxiety Questionnaire. Motion artefacts were evaluated by three observers, blinded to the information given. Data were collected between April 2015-April 2016. The study followed the CONSORT guidelines. The CMR-video group scored lower (better) than the cardiovascular magnetic resonance imaging-standard group in the factor Relaxation (p = .039) but not in the factor Anxiety. Anxiety levels were lower during scintigraphic examinations compared to the CMR-standard group (p < .001). No difference was found regarding motion artefacts between CMR-video and CMR-standard. Patient ability to relax during cardiovascular magnetic resonance imaging increased by adding video information prior the exam, which is important in relation to perceived quality in nursing. No effect was seen on motion artefacts. Video information prior to examinations can be an easy and time effective method to help patients cooperate in imaging procedures. © 2017 John Wiley & Sons Ltd.

  19. Magnetic resonance imaging of the long head of the biceps tendon: benefit of coplanar image.

    PubMed

    Lin, Anderson; Ting, Julius; Lee, Kwo-Whei

    2007-01-01

    To evaluate coplanar imaging of the long head of the biceps tendon. We retrospectively compared coronal oblique magnetic resonance images aligned with the principal supraspinatus tendon and with the intra-articular biceps tendon in 21 patients. Magnetic resonance images were analyzed for lesions depicted, including superior labral anteroposterior (SLAP) tears. Arthroscopic findings were reviewed. Coronal oblique images aligned with intra-articular biceps tendon depicted 18 (86%) of 21 coplanar intra-articular biceps tendons. Coplanar images identified 6 cases of tendinosis, 1 tear, 3 intra-articular ruptures, and 20 (95.2%) of 21 exact origins of the tendon. Arthroscopy revealed 18 SLAP tears. The detection of SLAP lesions between both coronal oblique magnetic resonance images was significantly different (P = 0.007). Advantages included imaging of the intra-articular biceps tendon with least partial-volume effects, definition of SLAP lesions and the tendinous origin at the supraglenoid tubercle, depiction of intra-articular bicipital ruptures, and increased sensitivity and specificity for intra-articular lesions.

  20. Sensitivity enhancement of traveling wave MRI using free local resonators: an experimental demonstration.

    PubMed

    Zhang, Xiaoliang

    2017-04-01

    Traveling wave MR uses the far fields in signal excitation and reception, therefore its acquisition efficiency is low in contrast to the conventional near field magnetic resonance (MR). Here we show a simple and efficient method based on the local resonator to improving sensitivity of traveling wave MR technique. The proposed method utilizes a standalone or free local resonator to amplify the radio frequency magnetic fields in the interested target. The resonators have no wire connections to the MR system and thus can be conveniently placed to any place around imaging simples. A rectangular loop L/C resonator to be used as the free local resonator was tuned to the proton Larmor frequency at 7T. Traveling wave MR experiments with and without the wireless free local resonator were performed on a living rat using a 7T whole body MR scanner. The signal-to-noise ratio (SNR) or sensitivity of the images acquired was compared and evaluated. In vivo 7T imaging results show that traveling wave MR with a wireless free local resonator placed near the head of a living rat achieves at least 10-fold SNR gain over the images acquired on the same rat using conventional traveling wave MR method, i.e. imaging with no free local resonators. The proposed free local resonator technique is able to enhance the MR sensitivity and acquisition efficiency of traveling wave MR at ultrahigh fields in vivo . This method can be a simple solution to alleviating low sensitivity problem of traveling wave MRI.

  1. Posterior Cord Syndrome and Trace Elements Deficiency as an Uncommon Presentation of Common Variable Immunodeficiency

    PubMed Central

    dos Santos Mota, Ananda; Morais Monteiro, Priscila; Carvalho, Angela Cristina Gouvêa; Fernandes Diniz, Barbara; Gemal Lanzieri, Pedro; Carneiro Ramos, Ricardo; Mocarzel, Luis Otavio

    2017-01-01

    Diarrhea is one of the most common symptoms in common variable immunodeficiency, but neurologic manifestations are rare. We presented a 50-year-old woman with recurrent diarrhea and severe weight loss that developed a posterior cord syndrome. Endoscopy found a duodenal villous blunting, intraepithelial lymphocytosis, and lack of plasma cells and magnetic resonance imaging of the spine was normal. Laboratory assays confirmed common variable immunodeficiency syndrome and showed low levels of trace elements (copper and zinc). Treatment was initiated with parenteral replacement of trace elements and intravenous human immunoglobulin and the patient improved clinically. In conclusion, physicians must be aware that gastrointestinal and neurologic disorders may be related to each other and remember to request trace elements laboratory assessment. PMID:28356913

  2. Proton pump inhibitors and symptomatic hypomagnesemic hypoparathyroidism.

    PubMed

    Fatuzzo, P; Portale, G; Scollo, V; Zanoli, L; Granata, Antonio

    2017-04-01

    Hypomagnesemia is a common but often overlooked problem in hospitalized patients. Unrecognized hypomagnesemia can cause serious complications. The association of hypokalemia and hypocalcemia is strongly evocative of a magnesium deficiency. Research into the causes of hypomagnesemia is imperative, as it will definitely change the approach, treatment and prognosis. We report the case of a 65-year-old man with chronic hypocalcemia and hypokalemia associated with cerebellar syndrome, a solitary seizure and cerebellar hyperintensities on magnetic resonance imaging. After the detection and treatment of hypomagnesemia with oral supplements of magnesium and the replacement of pantoprazole with ranitidine, we observed immediate relief of the symptoms. In conclusion, in clinical practice, magnesium depletion should be investigated in elderly patients with hypocalcemia treated with proton pump inhibitors for many years, in particular in the presence of neurological disorders.

  3. [Spiral CT angiography in practice].

    PubMed

    Pavcec, Zlatko; Zokalj, Ivan; Rumboldt, Zoran; Pal, Andrej; Saghir, Hussein; Ozretić, David; Latin, Branko; Perhoć, Zeljka; Marotti, Miljenko

    2005-01-01

    Incidence of vascular diseases and development of new radiologic techniques in the last three decades has given strong impuls for introduction of non-invasive vascular diagnostic methods. Thanks to the introduction of Doppler ultrasound, new types of computed tomography (CT) and magnetic resonance (MR) scanners, non-invasive vascular diagnostic methods are replacing conventional invasive (catheter) angiographic methods. Computed tomographic angiography (CTA) is a noninvasive vascular diagnostic method based on continuous scanning with CT scanner during intravenous application of contrast material. Performing of CTA is possible after introduction of spiral CT technique whose characteristics are short imaging time and volumetric data acquisition. The main goal of this article, based on our experiences, is to review the role of CTA, performed on single-slice CT scanner, in managment of patients with vascular pathology.

  4. Use of monoglyceride hydrogel for the production of low fat short dough pastry.

    PubMed

    Manzocco, Lara; Anese, Monica; Calligaris, Sonia; Quarta, Barbara; Nicoli, Maria Cristina

    2012-05-01

    The influence of palm oil replacement with a monoglyceride-palm oil-water gel (hydrogel) on physical properties and acrylamide content of a low fat short dough pastry was studied. The effect of the incorporation of the hydrogel was monitored during storage by assessing moisture, firmness, proton density/mobility using magnetic resonance imaging (MRI) and acrylamide content. The use of hydrogel allowed the lipid content of pastries to be reduced with minor effects on their quality characteristics. However, the hydrogel-containing pastries showed a crunchier crust, higher acrylamide content and a higher tendency to staling. As assessed by MRI, these results were ascribable to the development of a peculiar system morphology promoted by hydrogel incorporation in the food matrix. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Stereotactic ultrasound for target volume definition in a patient with prostate cancer and bilateral total hip replacement.

    PubMed

    Boda-Heggemann, Judit; Haneder, Stefan; Ehmann, Michael; Sihono, Dwi Seno Kuncoro; Wertz, Hansjörg; Mai, Sabine; Kegel, Stefan; Heitmann, Sigrun; von Swietochowski, Sandra; Lohr, Frank; Wenz, Frederik

    2015-01-01

    Target-volume definition for prostate cancer in patients with bilateral metal total hip replacements (THRs) is a challenge because of metal artifacts in the planning computed tomography (CT) scans. Magnetic resonance imaging (MRI) can be used for matching and prostate delineation; however, at a spatial and temporal distance from the planning CT, identical rectal and vesical filling is difficult to achieve. In addition, MRI may also be impaired by metal artifacts, even resulting in spatial image distortion. Here, we present a method to define prostate target volumes based on ultrasound images acquired during CT simulation and online-matched to the CT data set directly at the planning CT. A 78-year-old patient with cT2cNxM0 prostate cancer with bilateral metal THRs was referred to external beam radiation therapy. T2-weighted MRI was performed on the day of the planning CT with preparation according to a protocol for reproducible bladder and rectal filling. The planning CT was obtained with the immediate acquisition of a 3-dimensional ultrasound data set with a dedicated stereotactic ultrasound system for online intermodality image matching referenced to the isocenter by ceiling-mounted infrared cameras. MRI (offline) and ultrasound images (online) were thus both matched to the CT images for planning. Daily image guided radiation therapy (IGRT) was performed with transabdominal ultrasound and compared with cone beam CT. Because of variations in bladder and rectal filling and metal-induced image distortion in MRI, soft-tissue-based matching of the MRI to CT was not sufficient for unequivocal prostate target definition. Ultrasound-based images could be matched, and prostate, seminal vesicles, and target volumes were reliably defined. Daily IGRT could be successfully completed with transabdominal ultrasound with good accordance between cone beam CT and ultrasound. For prostate cancer patients with bilateral THRs causing artifacts in planning CTs, ultrasound referenced to the isocenter of the CT simulator and acquired with intermodal online coregistration directly at the planning CT is a fast and easy method to reliably delineate the prostate and target volumes and for daily IGRT. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  6. Magnetic resonance imaging based functional imaging in paediatric oncology.

    PubMed

    Manias, Karen A; Gill, Simrandip K; MacPherson, Lesley; Foster, Katharine; Oates, Adam; Peet, Andrew C

    2017-02-01

    Imaging is central to management of solid tumours in children. Conventional magnetic resonance imaging (MRI) is the standard imaging modality for tumours of the central nervous system (CNS) and limbs and is increasingly used in the abdomen. It provides excellent structural detail, but imparts limited information about tumour type, aggressiveness, metastatic potential or early treatment response. MRI based functional imaging techniques, such as magnetic resonance spectroscopy, diffusion and perfusion weighted imaging, probe tissue properties to provide clinically important information about metabolites, structure and blood flow. This review describes the role of and evidence behind these functional imaging techniques in paediatric oncology and implications for integrating them into routine clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Spatial Distortion in MRI-Guided Stereotactic Procedures: Evaluation in 1.5-, 3- and 7-Tesla MRI Scanners.

    PubMed

    Neumann, Jan-Oliver; Giese, Henrik; Biller, Armin; Nagel, Armin M; Kiening, Karl

    2015-01-01

    Magnetic resonance imaging (MRI) is replacing computed tomography (CT) as the main imaging modality for stereotactic transformations. MRI is prone to spatial distortion artifacts, which can lead to inaccuracy in stereotactic procedures. Modern MRI systems provide distortion correction algorithms that may ameliorate this problem. This study investigates the different options of distortion correction using standard 1.5-, 3- and 7-tesla MRI scanners. A phantom was mounted on a stereotactic frame. One CT scan and three MRI scans were performed. At all three field strengths, two 3-dimensional sequences, volumetric interpolated breath-hold examination (VIBE) and magnetization-prepared rapid acquisition with gradient echo, were acquired, and automatic distortion correction was performed. Global stereotactic transformation of all 13 datasets was performed and two stereotactic planning workflows (MRI only vs. CT/MR image fusion) were subsequently analysed. Distortion correction on the 1.5- and 3-tesla scanners caused a considerable reduction in positional error. The effect was more pronounced when using the VIBE sequences. By using co-registration (CT/MR image fusion), even a lower positional error could be obtained. In ultra-high-field (7 T) MR imaging, distortion correction introduced even higher errors. However, the accuracy of non-corrected 7-tesla sequences was comparable to CT/MR image fusion 3-tesla imaging. MRI distortion correction algorithms can reduce positional errors by up to 60%. For stereotactic applications of utmost precision, we recommend a co-registration to an additional CT dataset. © 2015 S. Karger AG, Basel.

  8. Geometric Computation of Human Gyrification Indexes from Magnetic Resonance Images

    DTIC Science & Technology

    2009-04-01

    GEOMETRIC COMPUTATION OF HUMAN GYRIFICATION INDEXES FROM MAGNETIC RESONANCE IMAGES By Shu Su Tonya White Marcus Schmidt Chiu-Yen Kao and Guillermo...00-2009 to 00-00-2009 4. TITLE AND SUBTITLE Geometric Computation of Human Gyrification Indexes from Magnetic Resonance Images 5a. CONTRACT NUMBER... Geometric Computation of Gyrification Indexes Chiu-Yen Kao 1 Geometric Computation of Human Gyrification

  9. The administration of psilocybin to healthy, hallucinogen-experienced volunteers in a mock-functional magnetic resonance imaging environment: a preliminary investigation of tolerability.

    PubMed

    Carhart-Harris, Robin L; Williams, Tim M; Sessa, Ben; Tyacke, Robin J; Rich, Ann S; Feilding, Amanda; Nutt, David J

    2011-11-01

    This study sought to assess the tolerability of intravenously administered psilocybin in healthy, hallucinogen-experienced volunteers in a mock-magnetic resonance imaging environment as a preliminary stage to a controlled investigation using functional magnetic resonance imaging to explore the effects of psilocybin on cerebral blood flow and activity. The present pilot study demonstrated that up to 2 mg of psilocybin delivered as a slow intravenous injection produces short-lived but typical drug effects that are psychologically and physiologically well tolerated. With appropriate care, this study supports the viability of functional magnetic resonance imaging work with psilocybin.

  10. Combined magnetic resonance imaging approach for the assessment of in vivo knee joint kinematics under full weight-bearing conditions.

    PubMed

    Al Hares, Ghaith; Eschweiler, Jörg; Radermacher, Klaus

    2015-06-01

    The development of detailed and specific knowledge on the biomechanical behavior of loaded knee structures has received increased attention in recent years. Stress magnetic resonance imaging techniques have been introduced in previous work to study knee kinematics under load conditions. Previous studies captured the knee movement either in atypical loading supine positions, or in upright positions with help of inclined supporting backrests being insufficient for movement capture under full-body weight-bearing conditions. In this work, we used a combined magnetic resonance imaging approach for measurement and assessment in knee kinematics under full-body weight-bearing in single legged stance. The proposed method is based on registration of high-resolution static magnetic resonance imaging data acquired in supine position with low-resolution data, quasi-static upright-magnetic resonance imaging data acquired in loaded positions for different degrees of knee flexion. The proposed method was applied for the measurement of tibiofemoral kinematics in 10 healthy volunteers. The combined magnetic resonance imaging approach allows the non-invasive measurement of knee kinematics in single legged stance and under physiological loading conditions. We believe that this method can provide enhanced understanding of the loaded knee kinematics. © IMechE 2015.

  11. Magnetic resonance imaging measurement of iron overload

    PubMed Central

    Wood, John C.

    2010-01-01

    Purpose of review To highlight recent advances in magnetic resonance imaging estimation of somatic iron overload. This review will discuss the need and principles of magnetic resonance imaging-based iron measurements, the validation of liver and cardiac iron measurements, and the key institutional requirements for implementation. Recent findings Magnetic resonance imaging assessment of liver and cardiac iron has achieved critical levels of availability, utility, and validity to serve as the primary endpoint of clinical trials. Calibration curves for the magnetic resonance imaging parameters R2 and R2* (or their reciprocals, T2 and T2*) have been developed for the liver and the heart. Interscanner variability for these techniques has proven to be on the order of 5–7%. Summary Magnetic resonance imaging assessment of tissue iron is becoming increasingly important in the management of transfusional iron load because it is noninvasive, relatively widely available and offers a window into presymptomatic organ dysfunction. The techniques are highly reproducible within and across machines and have been chemically validated in the liver and the heart. These techniques will become the standard of care as industry begins to support the acquisition and postprocessing software. PMID:17414205

  12. High frequency resonant waveguide grating imager for assessing drug-induced cardiotoxicity

    NASA Astrophysics Data System (ADS)

    Ferrie, Ann M.; Wu, Qi; Deichmann, Oberon D.; Fang, Ye

    2014-05-01

    We report a high-frequency resonant waveguide grating imager for assessing compound-induced cardiotoxicity. The imager sweeps the wavelength range from 823 nm to 838 nm every 3 s to identify and monitor compound-induced shifts in resonance wavelength and then switch to the intensity-imaging mode to detect the beating rhythm and proarrhythmic effects of compounds on induced pluripotent stem cell-derived cardiomyocytes. This opens possibility to study cardiovascular biology and compound-induced cardiotoxicity.

  13. [Joint correction for motion artifacts and off-resonance artifacts in multi-shot diffusion magnetic resonance imaging].

    PubMed

    Wu, Wenchuan; Fang, Sheng; Guo, Hua

    2014-06-01

    Aiming at motion artifacts and off-resonance artifacts in multi-shot diffusion magnetic resonance imaging (MRI), we proposed a joint correction method in this paper to correct the two kinds of artifacts simultaneously without additional acquisition of navigation data and field map. We utilized the proposed method using multi-shot variable density spiral sequence to acquire MRI data and used auto-focusing technique for image deblurring. We also used direct method or iterative method to correct motion induced phase errors in the process of deblurring. In vivo MRI experiments demonstrated that the proposed method could effectively suppress motion artifacts and off-resonance artifacts and achieve images with fine structures. In addition, the scan time was not increased in applying the proposed method.

  14. Acoustic superlens using Helmholtz-resonator-based metamaterials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xishan; Yin, Jing; Yu, Gaokun, E-mail: gkyu@ouc.edu.cn

    2015-11-09

    Acoustic superlens provides a way to overcome the diffraction limit with respect to the wavelength of the bulk wave in air. However, the operating frequency range of subwavelength imaging is quite narrow. Here, an acoustic superlens is designed using Helmholtz-resonator-based metamaterials to broaden the bandwidth of super-resolution. An experiment is carried out to verify subwavelength imaging of double slits, the imaging of which can be well resolved in the frequency range from 570 to 650 Hz. Different from previous works based on the Fabry-Pérot resonance, the corresponding mechanism of subwavelength imaging is the Fano resonance, and the strong coupling between themore » neighbouring Helmholtz resonators separated at the subwavelength interval leads to the enhanced sound transmission over a relatively wide frequency range.« less

  15. Does non-echo-planar diffusion-weighted magnetic resonance imaging have a role in assisting the clinical diagnosis of cholesteatoma in selected cases?

    PubMed

    Nash, R; Lingam, R K; Chandrasekharan, D; Singh, A

    2018-03-01

    To determine the diagnostic performance of diffusion-weighted magnetic resonance imaging in the assessment of patients with suspected, but not clinically evident, cholesteatoma. A retrospective analysis of a prospectively collected database of non-echo-planar diffusion-weighted magnetic resonance imaging studies (using a half-Fourier single-shot turbo-spin echo sequence) was conducted. Clinical records were retrospectively reviewed to determine indications for imaging and operative findings. Seventy-eight investigations in 74 patients with suspected cholesteatoma aged 5.7-79.2 years (mean, 41.7 years) were identified. Operative confirmation was available in 44 ears. Diagnostic accuracy of the imaging technique was calculated using operative findings as a 'gold standard'. Sensitivity of the investigation was examined via comparison with clinically evident cholesteatoma. The accuracy of diffusion-weighted magnetic resonance imaging in assessment of suspected cholesteatoma was 63.6 per cent. The imaging technique was significantly less accurate in assessment of suspected cholesteatoma than clinically evident disease (p < 0.001). Computed tomography and diffusion-weighted magnetic resonance imaging may be complementary in assessment of suspected cholesteatoma, but should be used with caution, and clinical judgement is paramount.

  16. New approaches for measuring changes in the cortical surface using an automatic reconstruction algorithm

    NASA Astrophysics Data System (ADS)

    Pham, Dzung L.; Han, Xiao; Rettmann, Maryam E.; Xu, Chenyang; Tosun, Duygu; Resnick, Susan; Prince, Jerry L.

    2002-05-01

    In previous work, the authors presented a multi-stage procedure for the semi-automatic reconstruction of the cerebral cortex from magnetic resonance images. This method suffered from several disadvantages. First, the tissue classification algorithm used can be sensitive to noise within the image. Second, manual interaction was required for masking out undesired regions of the brain image, such as the ventricles and putamen. Third, iterated median filters were used to perform a topology correction on the initial cortical surface, resulting in an overly smoothed initial surface. Finally, the deformable surface used to converge to the cortex had difficulty capturing narrow gyri. In this work, all four disadvantages of the procedure have been addressed. A more robust tissue classification algorithm is employed and the manual masking step is replaced by an automatic method involving level set deformable models. Instead of iterated median filters, an algorithm developed specifically for topology correction is used. The last disadvantage is addressed using an algorithm that artificially separates adjacent sulcal banks. The new procedure is more automated but also more accurate than the previous one. Its utility is demonstrated by performing a preliminary study on data from the Baltimore Longitudinal Study of Aging.

  17. Medial-based deformable models in nonconvex shape-spaces for medical image segmentation.

    PubMed

    McIntosh, Chris; Hamarneh, Ghassan

    2012-01-01

    We explore the application of genetic algorithms (GA) to deformable models through the proposition of a novel method for medical image segmentation that combines GA with nonconvex, localized, medial-based shape statistics. We replace the more typical gradient descent optimizer used in deformable models with GA, and the convex, implicit, global shape statistics with nonconvex, explicit, localized ones. Specifically, we propose GA to reduce typical deformable model weaknesses pertaining to model initialization, pose estimation and local minima, through the simultaneous evolution of a large number of models. Furthermore, we constrain the evolution, and thus reduce the size of the search-space, by using statistically-based deformable models whose deformations are intuitive (stretch, bulge, bend) and are driven in terms of localized principal modes of variation, instead of modes of variation across the entire shape that often fail to capture localized shape changes. Although GA are not guaranteed to achieve the global optima, our method compares favorably to the prevalent optimization techniques, convex/nonconvex gradient-based optimizers and to globally optimal graph-theoretic combinatorial optimization techniques, when applied to the task of corpus callosum segmentation in 50 mid-sagittal brain magnetic resonance images.

  18. Gleason Score Determination with Transrectal Ultrasound-Magnetic Resonance Imaging Fusion Guided Prostate Biopsies--Are We Gaining in Accuracy?

    PubMed

    Lanz, Camille; Cornud, François; Beuvon, Frédéric; Lefèvre, Arnaud; Legmann, Paul; Zerbib, Marc; Delongchamps, Nicolas Barry

    2016-01-01

    We evaluated the accuracy of prostate magnetic resonance imaging- transrectal ultrasound targeted biopsy for Gleason score determination. We selected 125 consecutive patients treated with radical prostatectomy for a clinically localized prostate cancer diagnosed on magnetic resonance imaging-transrectal ultrasound targeted biopsy and/or systematic biopsy. On multiparametric magnetic resonance imaging each suspicious area was graded according to PI-RADS™ score. A correlation analysis between multiparametric magnetic resonance imaging and pathological findings was performed. Factors associated with determining the accuracy of Gleason score on targeted biopsy were statistically assessed. Pathological analysis of radical prostatectomy specimens detected 230 tumor foci. Multiparametric magnetic resonance imaging detected 151 suspicious areas. Of these areas targeted biopsy showed 126 cancer foci in 115 patients, and detected the index lesion in all of them. The primary Gleason grade, secondary Gleason grade and Gleason score of the 126 individual tumors were determined accurately in 114 (90%), 75 (59%) and 85 (67%) cases, respectively. Maximal Gleason score was determined accurately in 80 (70%) patients. Gleason score determination accuracy on targeted biopsy was significantly higher for low Gleason and high PI-RADS score tumors. Magnetic resonance imaging-transrectal ultrasound targeted biopsy allowed for an accurate estimation of Gleason score in more than two-thirds of patients. Gleason score misclassification was mostly due to a lack of accuracy in the determination of the secondary Gleason grade. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Transapical Aortic Valve Replacement under Real-time Magnetic Resonance Imaging Guidance: Experimental Results with Balloon-Expandable and Self-Expanding Stents

    PubMed Central

    Horvath, Keith A.; Mazilu, Dumitru; Kocaturk, Ozgur; Li, Ming

    2010-01-01

    Objective Aortic valves have been implanted on self-expanding (SE) and balloon-expandable (BE) stents minimally invasively. We have demonstrated the advantages of transapical aortic valve implantation (tAVI) under real-time magnetic resonance imaging (rtMRI) guidance. Whether there are different advantages to SE or BE stents is unknown. We report rtMRI guided tAVI in a porcine model using both SE and BE stents, and compare the differences between the stents. Methods Twenty-two Yucatan pigs (45-57kgs.) underwent tAVI. Commercially available stentless bioprostheses (21-25mm) were mounted on either BE platinum-iridium stents or SE nitinol stents. rtMRI guidance was employed as the intraoperative imaging. Markers on both types of stents were used to enhance the visualization in rtMRI. Pigs were allowed to survive and had follow-up MRI scans and echocardiography at 1, 3 and 6 months postoperatively. Results rtMRI provided excellent visualization of the aortic valve implantation mounted on both stent types. The implantation times were shorter with the SE stents (60±14 seconds) than BE (74±18s), (p=0.027). Total procedure time was 31 and 37 minutes respectively (p=0.12). It was considerably easier to manipulate the SE stent during deployment without hemodynamic compromise. This was not always the case with the BE stent and its placement occasionally resulted in coronary obstruction and death. Long-term results demonstrated stability of the implants with preservation of myocardial perfusion and function over time for both stents. Conclusions SE stents were easier to position and deploy thus leading to fewer complications during tAVI. Future optimization of SE stent design should improve clinical results. PMID:20971017

  20. Impact of scar thickness on the assessment of viability using dobutamine echocardiography and thallium single-photon emission computed tomography: a comparison with contrast-enhanced magnetic resonance imaging.

    PubMed

    Nelson, Charles; McCrohon, Jane; Khafagi, Frederick; Rose, Stephen; Leano, Rodel; Marwick, Thomas H

    2004-04-07

    We sought to determine whether the transmural extent of scar (TES) explains discordances between dobutamine echocardiography (DbE) and thallium single-photon emission computed tomography (Tl-SPECT) in the detection of viable myocardium (VM). Discrepancies between DbE and Tl-SPECT are often attributed to differences between contractile reserve and membrane integrity, but may also reflect a disproportionate influence of nontransmural scar on thickening at DbE. Sixty patients (age 62 +/- 12 years; 10 women and 50 men) with postinfarction left ventricular dysfunction underwent standard rest-late redistribution Tl-SPECT and DbE. Viable myocardium was identified when dysfunctional segments showed Tl activity >60% on the late-redistribution image or by low-dose augmentation at DbE. Contrast-enhanced magnetic resonance imaging (ceMRI) was used to divide TES into five groups: 0%, <25%, 26% to 50%, 51% to 75%, and >75% of the wall thickness replaced by scar. As TES increased, both the mean Tl uptake and change in wall motion score decreased significantly (both p < 0.001). However, the presence of subendocardial scar was insufficient to prevent thickening; >50% of segments still showed contractile function with TES of 25% to 75%, although residual function was uncommon with TES >75%. The relationship of both tests to increasing TES was similar, but Tl-SPECT identified VM more frequently than DbE in all groups. Among segments without scar or with small amounts of scar (<25% TES), >50% were viable by SPECT. Both contractile reserve and perfusion are sensitive to the extent of scar. However, contractile reserve may be impaired in the face of no or minor scar, and thickening may still occur with extensive scar.

  1. BLIPPED (BLIpped Pure Phase EncoDing) high resolution MRI with low amplitude gradients

    NASA Astrophysics Data System (ADS)

    Xiao, Dan; Balcom, Bruce J.

    2017-12-01

    MRI image resolution is proportional to the maximum k-space value, i.e. the temporal integral of the magnetic field gradient. High resolution imaging usually requires high gradient amplitudes and/or long spatial encoding times. Special gradient hardware is often required for high amplitudes and fast switching. We propose a high resolution imaging sequence that employs low amplitude gradients. This method was inspired by the previously proposed PEPI (π Echo Planar Imaging) sequence, which replaced EPI gradient reversals with multiple RF refocusing pulses. It has been shown that when the refocusing RF pulse is of high quality, i.e. sufficiently close to 180°, the magnetization phase introduced by the spatial encoding magnetic field gradient can be preserved and transferred to the following echo signal without phase rewinding. This phase encoding scheme requires blipped gradients that are identical for each echo, with low and constant amplitude, providing opportunities for high resolution imaging. We now extend the sequence to 3D pure phase encoding with low amplitude gradients. The method is compared with the Hybrid-SESPI (Spin Echo Single Point Imaging) technique to demonstrate the advantages in terms of low gradient duty cycle, compensation of concomitant magnetic field effects and minimal echo spacing, which lead to superior image quality and high resolution. The 3D imaging method was then applied with a parallel plate resonator RF probe, achieving a nominal spatial resolution of 17 μm in one dimension in the 3D image, requiring a maximum gradient amplitude of only 5.8 Gauss/cm.

  2. Magnetic resonance microscopy of prostate tissue: How basic science can inform clinical imaging development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bourne, Roger

    2013-03-15

    This commentary outlines how magnetic resonance imaging (MRI) microscopy studies of prostate tissue samples and whole organs have shed light on a number of clinical imaging mysteries and may enable more effective development of new clinical imaging methods.

  3. Current and potential imaging applications of ferumoxytol for magnetic resonance imaging.

    PubMed

    Toth, Gerda B; Varallyay, Csanad G; Horvath, Andrea; Bashir, Mustafa R; Choyke, Peter L; Daldrup-Link, Heike E; Dosa, Edit; Finn, John Paul; Gahramanov, Seymur; Harisinghani, Mukesh; Macdougall, Iain; Neuwelt, Alexander; Vasanawala, Shreyas S; Ambady, Prakash; Barajas, Ramon; Cetas, Justin S; Ciporen, Jeremy; DeLoughery, Thomas J; Doolittle, Nancy D; Fu, Rongwei; Grinstead, John; Guimaraes, Alexander R; Hamilton, Bronwyn E; Li, Xin; McConnell, Heather L; Muldoon, Leslie L; Nesbit, Gary; Netto, Joao P; Petterson, David; Rooney, William D; Schwartz, Daniel; Szidonya, Laszlo; Neuwelt, Edward A

    2017-07-01

    Contrast-enhanced magnetic resonance imaging is a commonly used diagnostic tool. Compared with standard gadolinium-based contrast agents, ferumoxytol (Feraheme, AMAG Pharmaceuticals, Waltham, MA), used as an alternative contrast medium, is feasible in patients with impaired renal function. Other attractive imaging features of i.v. ferumoxytol include a prolonged blood pool phase and delayed intracellular uptake. With its unique pharmacologic, metabolic, and imaging properties, ferumoxytol may play a crucial role in future magnetic resonance imaging of the central nervous system, various organs outside the central nervous system, and the cardiovascular system. Preclinical and clinical studies have demonstrated the overall safety and effectiveness of this novel contrast agent, with rarely occurring anaphylactoid reactions. The purpose of this review is to describe the general and organ-specific properties of ferumoxytol, as well as the advantages and potential pitfalls associated with its use in magnetic resonance imaging. To more fully demonstrate the applications of ferumoxytol throughout the body, an imaging atlas was created and is available online as supplementary material. Published by Elsevier Inc.

  4. Near-Resonant Imaging of Trapped Cold Atomic Samples

    PubMed Central

    You, L.; Lewenstein, Maciej

    1996-01-01

    We study the formation of diffraction patterns in the near-resonant imaging of trapped cold atomic samples. We show that the spatial imaging can provide detailed information on the trapped atomic clouds. PMID:27805110

  5. Brain PET scan

    MedlinePlus

    ... tissues are working. Other imaging tests, such as magnetic resonance imaging ( MRI ) and computed tomography ( CT ) scans only reveal ... M, Hellwig S, Kloppel S, Weiller C. Functional neuroimaging: functional magnetic resonance imaging, positron emission tomography, and single-photon emission computed ...

  6. Neural Signatures of Trust During Human-Automation Interactions

    DTIC Science & Technology

    2016-04-01

    magnetic resonance imaging by manipulating the reliability of advice from a human or automated luggage inspector framed as experts. HAT and HHT were...human-human trust, human-automation trust, brain, functional magnetic resonance imaging 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18...behavioral X-ray luggage-screening task with functional magnetic resonance imaging (fMRI) and manipulated reliabilities of advice (unknown to the

  7. Magnetic resonance imaging of the saccular otolithic mass.

    PubMed Central

    Sbarbati, A; Leclercq, F; Antonakis, K; Osculati, F

    1992-01-01

    The frog's inner ear was studied in vivo by high spatial resolution magnetic resonance imaging at 7 Tesla. The vestibule, the internal acoustic meatus, and the auditory tube have been identified. The large otolithic mass contained in the vestibule showed a virtual absence of magnetic resonance signal probably due to its composition of closely packed otoconia. Images Fig. 1 Fig. 2 Fig. 3 Fig. 5 PMID:1295875

  8. The Role of Cortical Plasticity in Recovery of Function Following Allogeneic Hand Transplantation

    DTIC Science & Technology

    2015-10-01

    transplantation, functional magnetic resonance imaging, hand replantation, cortical reorganization, functional recovery 16. SECURITY CLASSIFICATION OF: U...functional magnetic resonance imaging (fMRI) data suggest that areas of the sensory and motor cortex devoted to representing the hand prior to...function, recovery, functional magnetic resonance imaging 3. Accomplishments Major Goals Achieved: Year Two My lab is relocated to Washington University

  9. Reconstruction of pulse noisy images via stochastic resonance

    PubMed Central

    Han, Jing; Liu, Hongjun; Sun, Qibing; Huang, Nan

    2015-01-01

    We investigate a practical technology for reconstructing nanosecond pulse noisy images via stochastic resonance, which is based on the modulation instability. A theoretical model of this method for optical pulse signal is built to effectively recover the pulse image. The nanosecond noise-hidden images grow at the expense of noise during the stochastic resonance process in a photorefractive medium. The properties of output images are mainly determined by the input signal-to-noise intensity ratio, the applied voltage across the medium, and the correlation length of noise background. A high cross-correlation gain is obtained by optimizing these parameters. This provides a potential method for detecting low-level or hidden pulse images in various imaging applications. PMID:26067911

  10. Hearing colors: an example of brain plasticity

    PubMed Central

    Alfaro, Arantxa; Bernabeu, Ángela; Agulló, Carlos; Parra, Jaime; Fernández, Eduardo

    2015-01-01

    Sensory substitution devices (SSDs) are providing new ways for improving or replacing sensory abilities that have been lost due to disease or injury, and at the same time offer unprecedented opportunities to address how the nervous system could lead to an augmentation of its capacities. In this work we have evaluated a color-blind subject using a new visual-to-auditory SSD device called “Eyeborg”, that allows colors to be perceived as sounds. We used a combination of neuroimaging techniques including Functional Magnetic Resonance Imaging (fMRI), Diffusion Tensor Imaging (DTI) and proton Magnetic Resonance Spectroscopy (1H-MRS) to study potential brain plasticity in this subject. Our results suggest that after 8 years of continuous use of this device there could be significant adaptive and compensatory changes within the brain. In particular, we found changes in functional neural patterns, structural connectivity and cortical topography at the visual and auditive cortex of the Eyeborg user in comparison with a control population. Although at the moment we cannot claim that the continuous use of the Eyeborg is the only reason for these findings, our results may shed further light on potential brain changes associated with the use of other SSDs. This could help to better understand how the brain adapts to several pathologies and uncover adaptive resources such as cross-modal representations. We expect that the precise understanding of these changes will have clear implications for rehabilitative training, device development and for more efficient programs for people with disabilities. PMID:25926778

  11. Hearing colors: an example of brain plasticity.

    PubMed

    Alfaro, Arantxa; Bernabeu, Ángela; Agulló, Carlos; Parra, Jaime; Fernández, Eduardo

    2015-01-01

    Sensory substitution devices (SSDs) are providing new ways for improving or replacing sensory abilities that have been lost due to disease or injury, and at the same time offer unprecedented opportunities to address how the nervous system could lead to an augmentation of its capacities. In this work we have evaluated a color-blind subject using a new visual-to-auditory SSD device called "Eyeborg", that allows colors to be perceived as sounds. We used a combination of neuroimaging techniques including Functional Magnetic Resonance Imaging (fMRI), Diffusion Tensor Imaging (DTI) and proton Magnetic Resonance Spectroscopy ((1)H-MRS) to study potential brain plasticity in this subject. Our results suggest that after 8 years of continuous use of this device there could be significant adaptive and compensatory changes within the brain. In particular, we found changes in functional neural patterns, structural connectivity and cortical topography at the visual and auditive cortex of the Eyeborg user in comparison with a control population. Although at the moment we cannot claim that the continuous use of the Eyeborg is the only reason for these findings, our results may shed further light on potential brain changes associated with the use of other SSDs. This could help to better understand how the brain adapts to several pathologies and uncover adaptive resources such as cross-modal representations. We expect that the precise understanding of these changes will have clear implications for rehabilitative training, device development and for more efficient programs for people with disabilities.

  12. Aortic Dissection in Patients With Bicuspid Aortic Valve–Associated Aneurysms

    PubMed Central

    Wojnarski, Charles M.; Svensson, Lars G.; Roselli, Eric E.; Idrees, Jay J.; Lowry, Ashley M.; Ehrlinger, John; Pettersson, Gösta B.; Gillinov, A. Marc; Johnston, Douglas R.; Soltesz, Edward G.; Navia, Jose L.; Hammer, Donald F.; Griffin, Brian; Thamilarasan, Maran; Kalahasti, Vidyasagar; Sabik, Joseph F.; Blackstone, Eugene H.; Lytle, Bruce W.

    2016-01-01

    Background Data regarding the risk of aortic dissection in patients with bicuspid aortic valve and large ascending aortic diameter are limited, and appropriate timing of prophylactic ascending aortic replacement lacks consensus. Thus our objectives were to determine the risk of aortic dissection based on initial cross-sectional imaging data and clinical variables and to isolate predictors of aortic intervention in those initially prescribed serial surveillance imaging. Methods From January 1995 to January 2014, 1,181 patients with bicuspid aortic valve underwent cross-sectional computed tomography (CT) or magnetic resonance imaging (MRI) to ascertain sinus or tubular ascending aortic diameter greater than or equal to 4.7 cm. Random Forest classification was used to identify risk factors for aortic dissection, and among patients undergoing surveillance, time-related analysis was used to identify risk factors for aortic intervention. Results Prevalence of type A dissection that was detected by imaging or was found at operation or on follow-up was 5.3% (n = 63). Probability of type A dissection increased gradually at a sinus diameter of 5.0 cm—from 4.1% to 13% at 7.2 cm—and then increased steeply at an ascending aortic diameter of 5.3 cm—from 3.8% to 35% at 8.4 cm—corresponding to a cross-sectional area to height ratio of 10 cm2/m for sinuses of Valsalva and 13 cm2/m for the tubular ascending aorta. Cross-sectional area to height ratio was the best predictor of type A dissection (area under the curve [AUC] = 0.73). Conclusions Early prophylactic ascending aortic replacement in patients with bicuspid aortic valve should be considered at high-volume aortic centers to reduce the high risk of preventable type A dissection in those with aortas larger than approximately 5.0 cm or with a cross-sectional area to height ratio greater than approximately 10 cm2/m. PMID:26209494

  13. Shielded microstrip array for 7T human MR imaging.

    PubMed

    Wu, Bing; Wang, Chunsheng; Kelley, Douglas A C; Xu, Duan; Vigneron, Daniel B; Nelson, Sarah J; Zhang, Xiaoliang

    2010-01-01

    The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element is usually not sufficient to provide a perfect ground. Consequently, the transceiver array may suffer from cable resonance, lower Q-factors, and imaging quality degradations. In this paper, we present an approach to improving the performance of microstrip transceiver arrays by introducing RF shielding outside the microstrip array and the feeding coaxial cables. This improvement reduced interactions among cables, increased resonance stability, and Q-factors, and thus improved imaging quality. An experimental method was also introduced and utilized for quantitative measurement and evaluation of RF coil resonance stability or "cable resonance" behavior.

  14. Pain measurement and brain activity: will neuroimages replace pain ratings?

    PubMed

    Robinson, Michael E; Staud, Roland; Price, Donald D

    2013-04-01

    Arguments made for the advantages of replacing pain ratings with brain-imaging data include assumptions that pain ratings are less reliable and objective and that brain image data would greatly benefit the measurement of treatment efficacy. None of these assumptions are supported by available evidence. Self-report of pain is predictable and does not necessarily reflect unreliability or error. Because pain is defined as an experience, magnitudes of its dimensions can be estimated by well-established methods, including those used to validate brain imaging of pain. Brain imaging helps to study pain mechanisms and might be used as proxy measures of pain in persons unable to provide verbal reports. Yet eliminating pain ratings or replacing them with neuroimaging data is misguided because brain images only help explain pain if they are used in conjunction with self-report. There is no objective readout mechanism of pain (pain thermometer) that is unaffected by psychological factors. Benefits from including neuroimaging data might include increased understanding of underlying neural mechanisms of treatment efficacy, discovery of new treatment vectors, and support of conclusions derived from self-report. However, neither brain imaging nor self-report data are privileged over the other. The assumption that treatment efficacy is hampered by self-report has not been shown; there is a plethora of treatment studies showing that self-report is sensitive to treatment. Dismissal of patients' self-reports (pain ratings) by brain-imaging data is potentially harmful. The aim of replacing self-report with brain-imaging data is misguided and has no scientific or philosophical foundation. Although brain imaging may offer considerable insight into the neural mechanisms of pain, including relevant causes and correlations, brain images cannot and should not replace self-report. Only the latter assesses the experience of pain, which is not identical to neural activity. Brain imaging may help to explain pain, but replacing self-report with brain-imaging data would be philosophically and scientifically misguided and potentially harmful to pain patients. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  15. Improvement of Self-Injury With Dopamine and Serotonin Replacement Therapy in a Patient With a Hemizygous PAK3 Mutation: A New Therapeutic Strategy for Neuropsychiatric Features of an Intellectual Disability Syndrome.

    PubMed

    Horvath, Gabriella A; Tarailo-Graovac, Maja; Bartel, Tanja; Race, Simone; Van Allen, Margot I; Blydt-Hansen, Ingrid; Ross, Colin J; Wasserman, Wyeth W; Connolly, Mary B; van Karnebeek, Clara D M

    2018-01-01

    PAK3-related intellectual disability is caused by mutations in the gene encoding the p21-activated kinase (PAK) protein. It is characterized by mild to moderate cognitive impairment, micro/normocephaly, and a neurobehavioral phenotype characterized by short attention span, anxiety, restlessness, aggression, and self-abusive behaviors. The authors report a patient with a novel PAK3 mutation, who presented with intellectual disability, severe automutilation, and epilepsy. His magnetic resonance imaging changes were most likely secondary to lacerations from parenchymal contusions. His behavior was difficult to manage with behavior interventions or multiple medications. After finding low levels of dopamine and borderline low serotonin metabolites in the spinal fluid, treatment with low dose L-dopa/carbidopa and 5-hydroxytryptophan significantly improved his self-injurious behavior. This is the first case of PAK3-related intellectual disability presenting with severe self-injury with improvement following treatment. The patient's response to neurotransmitter replacement therapy raises the question if this treatment intervention might help other individuals suffering genetic syndromes and self-injurious behaviors.

  16. High resolution resonance ionization imaging detector and method

    DOEpatents

    Winefordner, James D.; Matveev, Oleg I.; Smith, Benjamin W.

    1999-01-01

    A resonance ionization imaging device (RIID) and method for imaging objects using the RIID are provided, the RIID system including a RIID cell containing an ionizable vapor including monoisotopic atoms or molecules, the cell being positioned to intercept scattered radiation of a resonance wavelength .lambda..sub.1 from the object which is to be detected or imaged, a laser source disposed to illuminate the RIID cell with laser radiation having a wavelength .lambda..sub.2 or wavelengths .lambda..sub.2, .lambda..sub.3 selected to ionize atoms in the cell that are in an excited state by virtue of having absorbed the scattered resonance laser radiation, and a luminescent screen at the back surface of the RIID cell which presents an image of the number and position of charged particles present in the RIID cell as a result of the ionization of the excited state atoms. The method of the invention further includes the step of initially illuminating the object to be detected or imaged with a laser having a wavelength selected such that the object will scatter laser radiation having the resonance wavelength .lambda..sub.1.

  17. Advances in magnetic resonance neuroimaging techniques in the evaluation of neonatal encephalopathy.

    PubMed

    Panigrahy, Ashok; Blüml, Stefan

    2007-02-01

    Magnetic resonance (MR) imaging has become an essential tool in the evaluation of neonatal encephalopathy. Magnetic resonance-compatible neonatal incubators allow sick neonates to be transported to the MR scanner, and neonatal head coils can improve signal-to-noise ratio, critical for advanced MR imaging techniques. Refinement of conventional imaging techniques include the use of PROPELLER techniques for motion correction. Magnetic resonance spectroscopic imaging and diffusion tensor imaging provide quantitative assessment of both brain development and brain injury in the newborn with respect to metabolite abnormalities and hypoxic-ischemic injury. Knowledge of normal developmental changes in MR spectroscopy metabolite concentration and diffusion tensor metrics is essential to interpret pathological cases. Perfusion MR and functional MR can provide additional physiological information. Both MR spectroscopy and diffusion tensor imaging can provide additional information in the differential of neonatal encephalopathy, including perinatal white matter injury, hypoxic-ischemic brain injury, metabolic disease, infection, and birth injury.

  18. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    PubMed

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  19. Gated-SPECT myocardial perfusion imaging as a complementary technique to magnetic resonance imaging in chronic myocardial infarction patients.

    PubMed

    Cuberas-Borrós, Gemma; Pineda, Victor; Aguadé-Bruix, Santiago; Romero-Farina, Guillermo; Pizzi, M Nazarena; de León, Gustavo; Castell-Conesa, Joan; García-Dorado, David; Candell-Riera, Jaume

    2013-09-01

    The aim of this study was to compare magnetic resonance and gated-SPECT myocardial perfusion imaging in patients with chronic myocardial infarction. Magnetic resonance imaging and gated-SPECT were performed in 104 patients (mean age, 61 [12] years; 87.5% male) with a previous infarction. Left ventricular volumes and ejection fraction and classic late gadolinium enhancement viability criteria (<75% transmurality) were correlated with those of gated-SPECT (uptake >50%) in the 17 segments of the left ventricle. Motion, thickening, and ischemia on SPECT were analyzed in segments showing nonviable tissue or equivocal enhancement features (50%-75% transmurality). A good correlation was observed between the 2 techniques for volumes, ejection fraction (P<.05), and estimated necrotic mass (P<.01). In total, 82 of 264 segments (31%) with >75% enhancement had >50% single SPECT uptake. Of the 106 equivocal segments on magnetic resonance imaging, 68 (64%) had >50% uptake, 41 (38.7%) had normal motion, 46 (43.4%) had normal thickening, and 17 (16%) had ischemic criteria on SPECT. A third of nonviable segments on magnetic resonance imaging showed >50% uptake on SPECT. Gated-SPECT can be useful in the analysis of motion, thickening, and ischemic criteria in segments with questionable viability on magnetic resonance imaging. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  20. Neuroimaging of HIV-associated cryptococcal meningitis: comparison of magnetic resonance imaging findings in patients with and without immune reconstitution.

    PubMed

    Katchanov, Juri; Branding, Gordian; Jefferys, Laura; Arastéh, Keikawus; Stocker, Hartmut; Siebert, Eberhard

    2016-02-01

    To determine the frequency, imaging characteristics, neuroanatomical distribution and dynamics of magnetic resonance imaging findings in HIV-associated cryptococcal meningitis in immunocompromised patients we compared patients without antiretroviral therapy with patients undergoing immune reconstitution. Neuroimaging and clinical data of 21 consecutive patients presenting to a German HIV centre in a 10-year period between 2005 and 2014 were reviewed. We identified eight patients with magnetic resonance imaging findings related to cryptococcal disease: five patients without antiretroviral therapy and three patients receiving effective antiretroviral therapy resulting in immune reconstitution. The pattern of magnetic resonance imaging manifestations was different in the two groups. In patients not on antiretroviral therapy, pseudocysts (n = 3) and lacunar ischaemic lesions (n = 2) were detected. Contrast-enhancing focal leptomeningeal and/or parenchymal lesions were found in all patients under immune reconstitution (n = 3). Magnetic resonance imaging lesions suggestive of leptomeningitis or meningoencephalitis were detected in all patients with a recurrence of cryptococcal meningitis under immune reconstitution, which differs from the classical magnetic resonance imaging findings in patients without antiretroviral therapy. In antiretroviral therapy-treated patients with past medical history of cryptococcal meningitis, detection of contrast-enhancing focal meningeal and/or parenchymal lesions should prompt further investigations for a recurrence of cryptococcal meningitis under immune reconstitution. © The Author(s) 2015.

  1. Iron overload in a teenager with xerocytosis: the importance of nuclear magnetic resonance imaging.

    PubMed

    Assis, Reijâne Alves de; Kassab, Carolina; Seguro, Fernanda Salles; Costa, Fernando Ferreira; Silveira, Paulo Augusto Achucarro; Wood, John; Hamerschlak, Nelson

    2013-12-01

    To report a case of iron overload secondary to xerocytosis, a rare disease in a teenager, diagnosed, by T2* magnetic resonance imaging. We report the case of a symptomatic patient with xerocytosis, a ferritin level of 350ng/mL and a significant cardiac iron overload. She was diagnosed by T2* magnetic resonance imaging and received chelation therapy Ektacytometric analysis confirmed the diagnosis of hereditary xerocytosis. Subsequent T2* magnetic resonance imaging demonstrated complete resolution of the iron overload in various organs, as a new echocardiography revealed a complete resolution of previous cardiac alterations. The patient remains in chelation therapy. Xerocytosis is a rare autosomal dominant genetic disorder characterized by dehydrated stomatocytosis. The patient may present with intense fatigue and iron overload. We suggest the regular use of T2* magnetic resonance imaging for the diagnosis and control of the response to iron chelation in xerocytosis, and we believe it can be used also in other hemolytic anemia requiring transfusions.

  2. The diagnostic accuracy of 1.5T magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries.

    PubMed

    Wade, Ryckie G; Itte, Vinay; Rankine, James J; Ridgway, John P; Bourke, Grainne

    2018-03-01

    Identification of root avulsions is of critical importance in traumatic brachial plexus injuries because it alters the reconstruction and prognosis. Pre-operative magnetic resonance imaging is gaining popularity, but there is limited and conflicting data on its diagnostic accuracy for root avulsion. This cohort study describes consecutive patients requiring brachial plexus exploration following trauma between 2008 and 2016. The index test was magnetic resonance imaging at 1.5 Tesla and the reference test was operative exploration of the supraclavicular plexus. Complete data from 29 males was available. The diagnostic accuracy of magnetic resonance imaging for root avulsion(s) of C5-T1 was 79%. The diagnostic accuracy of a pseudomeningocoele as a surrogate marker of root avulsion(s) of C5-T1 was 68%. We conclude that pseudomeningocoles were not a reliable sign of root avulsion and magnetic resonance imaging has modest diagnostic accuracy for root avulsions in the context of adult traumatic brachial plexus injuries. III.

  3. Magnetic resonance imaging of articular cartilage: trauma, degeneration, and repair.

    PubMed

    Potter, Hollis G; Foo, Li F

    2006-04-01

    The assessment of articular cartilage using magnetic resonance imaging has seen considerable advances in recent years. Cartilage morphologic characteristics can now be evaluated with a high degree of accuracy and reproducibility using dedicated pulse sequences, which are becoming standard at many institutions. These techniques detect clinically unsuspected traumatic cartilage lesions, allowing the physician to study their natural history with longitudinal evaluation and also to assess disease status in degenerative osteoarthritis. Magnetic resonance imaging also provides a more objective assessment of cartilage repair to augment the information obtained from more subjective clinical outcome instruments. Newly developed methods that provide detail at an ultrastructural level offer an important addition to cartilage evaluation, particularly in the detection of early alterations in the extracellular matrix. These methods have created an undeniably important role for magnetic resonance imaging in the reproducible, noninvasive, and objective evaluation and monitoring of cartilage. An overview of the advances, current techniques, and impact of magnetic resonance imaging in the setting of trauma, degenerative arthritides, and surgical treatment for cartilage injury is presented.

  4. A loop resonator for slice-selective in vivo EPR imaging in rats

    PubMed Central

    Hirata, Hiroshi; He, Guanglong; Deng, Yuanmu; Salikhov, Ildar; Petryakov, Sergey; Zweier, Jay L.

    2008-01-01

    A loop resonator was developed for 300-MHz continuous-wave electron paramagnetic resonance (CW-EPR) spectroscopy and imaging in live rats. A single-turn loop (55 mm in diameter) was used to provide sufficient space for the rat body. Efficiency for generating a radiofrequency magnetic field of 38 µT/W1/2 was achieved at the center of the loop. For the resonator itself, an unloaded quality factor of 430 was obtained. When a 350 g rat was placed in the resonator at the level of the lower abdomen, the quality factor decreased to 18. The sensitive volume in the loop was visualized with a bottle filled with an aqueous solution of the nitroxide spin probe 3-carbamoyl-2,2,5,5-tetramethyl-3-pyrrolin-1-yloxy (3-CP). The resonator was shown to enable EPR imaging in live rats. Imaging was performed for 3-CP that had been infused intravenously into the rat and its distribution was visualized within the lower abdomen. PMID:18006343

  5. Magnetic resonance imaging for the study of mummies.

    PubMed

    Giovannetti, Giulio; Guerrini, Andrea; Carnieri, Emiliano; Salvadori, Piero A

    2016-07-01

    Nondestructive diagnostic imaging for mummies study has a long tradition and high-resolution images of the samples morphology have been extensively acquired by using computed tomography (CT). However, although in early reports no signal or image was obtained because of the low water content, mummy magnetic resonance imaging (MRI) was demonstrated able to generate images of such ancient specimens by using fast imaging techniques. Literature demonstrated the general feasibility of nonclinical MRI for visualizing historic human tissues, which is particularly interesting for archeology. More recently, multinuclear magnetic resonance spectroscopy (MRS) was demonstrated able to detect numerous organic biochemicals from such remains. Although the quality of these images is not yet comparable to that of clinical magnetic resonance (MR) images, and further research will be needed for determining the full capacity of MR in this topic, the information obtained with MR can be viewed as complementary to the one provided by CT and useful for paleoradiological studies of mummies. This work contains an overview of the state of art of the emerging uses of MRI in paleoradiology. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI.

    PubMed

    Asif, M Salman; Hamilton, Lei; Brummer, Marijn; Romberg, Justin

    2013-09-01

    Accelerated magnetic resonance imaging techniques reduce signal acquisition time by undersampling k-space. A fundamental problem in accelerated magnetic resonance imaging is the recovery of quality images from undersampled k-space data. Current state-of-the-art recovery algorithms exploit the spatial and temporal structures in underlying images to improve the reconstruction quality. In recent years, compressed sensing theory has helped formulate mathematical principles and conditions that ensure recovery of (structured) sparse signals from undersampled, incoherent measurements. In this article, a new recovery algorithm, motion-adaptive spatio-temporal regularization, is presented that uses spatial and temporal structured sparsity of MR images in the compressed sensing framework to recover dynamic MR images from highly undersampled k-space data. In contrast to existing algorithms, our proposed algorithm models temporal sparsity using motion-adaptive linear transformations between neighboring images. The efficiency of motion-adaptive spatio-temporal regularization is demonstrated with experiments on cardiac magnetic resonance imaging for a range of reduction factors. Results are also compared with k-t FOCUSS with motion estimation and compensation-another recently proposed recovery algorithm for dynamic magnetic resonance imaging. . Copyright © 2012 Wiley Periodicals, Inc.

  7. Injection-controlled laser resonator

    DOEpatents

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  8. Injection-controlled laser resonator

    DOEpatents

    Chang, Jim J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality.

  9. Pathological and 3 Tesla Volumetric Magnetic Resonance Imaging Predictors of Biochemical Recurrence after Robotic Assisted Radical Prostatectomy: Correlation with Whole Mount Histopathology.

    PubMed

    Tan, Nelly; Shen, Luyao; Khoshnoodi, Pooria; Alcalá, Héctor E; Yu, Weixia; Hsu, William; Reiter, Robert E; Lu, David Y; Raman, Steven S

    2018-05-01

    We sought to identify the clinical and magnetic resonance imaging variables predictive of biochemical recurrence after robotic assisted radical prostatectomy in patients who underwent multiparametric 3 Tesla prostate magnetic resonance imaging. We performed an institutional review board approved, HIPAA (Health Insurance Portability and Accountability Act) compliant, single arm observational study of 3 Tesla multiparametric magnetic resonance imaging prior to robotic assisted radical prostatectomy from December 2009 to March 2016. Clinical, magnetic resonance imaging and pathological information, and clinical outcomes were compiled. Biochemical recurrence was defined as prostate specific antigen 0.2 ng/cc or greater. Univariate and multivariate regression analysis was performed. Biochemical recurrence had developed in 62 of the 255 men (24.3%) included in the study at a median followup of 23.5 months. Compared to the subcohort without biochemical recurrence the subcohort with biochemical recurrence had a greater proportion of patients with a high grade biopsy Gleason score, higher preoperative prostate specific antigen (7.4 vs 5.6 ng/ml), intermediate and high D'Amico classifications, larger tumor volume on magnetic resonance imaging (0.66 vs 0.30 ml), higher PI-RADS® (Prostate Imaging-Reporting and Data System) version 2 category lesions, a greater proportion of intermediate and high grade radical prostatectomy Gleason score lesions, higher pathological T3 stage (all p <0.01) and a higher positive surgical margin rate (19.3% vs 7.8%, p = 0.016). On multivariable analysis only tumor volume on magnetic resonance imaging (adjusted OR 1.57, p = 0.016), pathological T stage (adjusted OR 2.26, p = 0.02), positive surgical margin (adjusted OR 5.0, p = 0.004) and radical prostatectomy Gleason score (adjusted OR 2.29, p = 0.004) predicted biochemical recurrence. In this cohort tumor volume on magnetic resonance imaging and pathological variables, including Gleason score, staging and positive surgical margins, significantly predicted biochemical recurrence. This suggests an important new imaging biomarker. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Diagnosing Autism Spectrum Disorder through Brain Functional Magnetic Resonance Imaging

    DTIC Science & Technology

    2016-03-01

    Diagnosing Autism Spectrum Disorder through Brain Functional Magnetic Resonance Imaging THESIS MARCH 2016 Kyle A. Palko, Second Lieutenant, USAF AFIT...declared a work of the U.S. Government and is not subject to copyright protection in the United States. AFIT-ENC-MS-16-M-123 DIAGNOSING AUTISM SPECTRUM...PUBLIC RELEASE; DISTRIBUTION UNLIMITED. AFIT-ENC-MS-16-M-123 DIAGNOSING AUTISM SPECTRUM DISORDER THROUGH BRAIN FUNCTIONAL MAGNETIC RESONANCE IMAGING Kyle

  11. Magnetic Resonance Imaging of Tumors with the Use of Iron Oxide Magnetic Nanoparticles as a Contrast Agent.

    PubMed

    Semkina, A S; Abakumov, M A; Grinenko, N F; Lipengolts, A A; Nukolova, N V; Chekhonin, V P

    2017-04-01

    We studied the possibility of using BSA-coated magnetic iron oxide nanoparticles for magnetic resonance imaging diagnosis of C6 glioblastoma, 4T1 mammary adenocarcinoma, and RS-1 hepatic mucous carcinoma. In all three cases, magnetic nanoparticles accumulated in the tumor and its large vessels. Magnetic resonance imaging with contrast agent allows visualization of the tumor tissue and its vascularization.

  12. Magnetic Resonance Imaging of Benign and Malignant Uterine Neoplasms.

    PubMed

    Leursen, Gustavo; Gardner, Carly Susan; Sagebiel, Tara; Patnana, Madhavi; de CastroFaria, Silvana; Devine, Catherine E; Bhosale, Priya R

    2015-08-01

    Benign and malignant uterine masses can be seen in the women. Some of these are asymptomatic and incidentally discovered, whereas others can be symptomatic. With the soft tissue contrast resolution magnetic resonance imaging can render a definitive diagnosis, which can further help streamline patient management. In this article we show magnetic resonance imaging examples of benign and malignant masses of the uterus and their treatment strategies. Published by Elsevier Inc.

  13. Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

    PubMed

    Li, Ye; Yu, Baiying; Pang, Yong; Vigneron, Daniel B; Zhang, Xiaoliang

    2013-01-01

    The use of quadrature RF magnetic fields has been demonstrated to be an efficient method to reduce transmit power and to increase the signal-to-noise (SNR) in magnetic resonance (MR) imaging. The goal of this project was to develop a new method using the common-mode and differential-mode (CMDM) technique for compact, planar, distributed-element quadrature transmit/receive resonators for MR signal excitation and detection and to investigate its performance for MR imaging, particularly, at ultrahigh magnetic fields. A prototype resonator based on CMDM method implemented by using microstrip transmission line was designed and fabricated for 7T imaging. Both the common mode (CM) and the differential mode (DM) of the resonator were tuned and matched at 298MHz independently. Numerical electromagnetic simulation was performed to verify the orthogonal B1 field direction of the two modes of the CMDM resonator. Both workbench tests and MR imaging experiments were carried out to evaluate the performance. The intrinsic decoupling between the two modes of the CMDM resonator was demonstrated by the bench test, showing a better than -36 dB transmission coefficient between the two modes at resonance frequency. The MR images acquired by using each mode and the images combined in quadrature showed that the CM and DM of the proposed resonator provided similar B1 coverage and achieved SNR improvement in the entire region of interest. The simulation and experimental results demonstrate that the proposed CMDM method with distributed-element transmission line technique is a feasible and efficient technique for planar quadrature RF coil design at ultrahigh fields, providing intrinsic decoupling between two quadrature channels and high frequency capability. Due to its simple and compact geometry and easy implementation of decoupling methods, the CMDM quadrature resonator can possibly be a good candidate for design blocks in multichannel RF coil arrays.

  14. Resting state fMRI: A review on methods in resting state connectivity analysis and resting state networks.

    PubMed

    Smitha, K A; Akhil Raja, K; Arun, K M; Rajesh, P G; Thomas, Bejoy; Kapilamoorthy, T R; Kesavadas, Chandrasekharan

    2017-08-01

    The inquisitiveness about what happens in the brain has been there since the beginning of humankind. Functional magnetic resonance imaging is a prominent tool which helps in the non-invasive examination, localisation as well as lateralisation of brain functions such as language, memory, etc. In recent years, there is an apparent shift in the focus of neuroscience research to studies dealing with a brain at 'resting state'. Here the spotlight is on the intrinsic activity within the brain, in the absence of any sensory or cognitive stimulus. The analyses of functional brain connectivity in the state of rest have revealed different resting state networks, which depict specific functions and varied spatial topology. However, different statistical methods have been introduced to study resting state functional magnetic resonance imaging connectivity, yet producing consistent results. In this article, we introduce the concept of resting state functional magnetic resonance imaging in detail, then discuss three most widely used methods for analysis, describe a few of the resting state networks featuring the brain regions, associated cognitive functions and clinical applications of resting state functional magnetic resonance imaging. This review aims to highlight the utility and importance of studying resting state functional magnetic resonance imaging connectivity, underlining its complementary nature to the task-based functional magnetic resonance imaging.

  15. Significance of perianular enhancement associated with anular tears on magnetic resonance imagings in diagnosis of radiculopathy.

    PubMed

    Byun, Woo Mok; Ahn, Sang Ho; Ahn, Myun-Whan

    2008-10-15

    Retrospective analysis of magnetic resonance imaging (MRI) and clinical findings about chemical radiculitis-associated anular tear in patients with radiculopathy. To investigate MRI findings of the chemical radiculitis caused by anular tears and to determine whether chemical radiculitis detected by MRI is the cause of radiculopathy. Many studies document that irritation of adjacent nerve roots by a chemical mediator of inflammation from the nucleus pulposus may result in radiculopathy. Computed tomography (CT) discography may be the best examination for diagnosing discogenic chemical radiculitis but is too invasive. A reliable imaging method for replacing invasive provocative CT discography and diagnosing chemical radiculitis is required. The study population consisted of 12 patients with pain referred to leg(s) with or without low back pain who underwent lumbar spine MRI. All cases of our study demonstrated perianular enhancement caused by chemical radiculitis associated with anular tears. Patterns and locations of perianular enhancement adjacent to anular tears on MRI were assessed. MRI findings were compared with clinical symptoms and/or provocative transforaminal epidural injection (n = 6). For documentation of the relationship between perianular enhancement and radiculopathy, provocative CT discography was performed in 2 cases. Perianular enhancement associated with anular tears revealed thick linear patterns (2.5-7 mm thickness) along margins of anular tears on contrast enhanced axial T1-weighted images with fat suppression. Locations of perianular enhancement adjacent to anular tears were at foraminal (n = 6) and extraforaminal portions (n = 6). CT discography showed a leak of contrast from anular tear to the perianular regions. Pain reproduction at contrast leak level during discography showed concordant pain. There was an apparent correlation between perianular enhancement on MRI and clinical symptoms or provocative epidural nerve root injection in all cases. The perianular enhancement adjacent to anular tears on MRI may be relevant in the diagnosis of symptomatic chemical radiculitis.

  16. Mouthpiece and Bell Effects on Trombone Resonance

    ERIC Educational Resources Information Center

    LoPresto, Michael C.

    2014-01-01

    The effects of the mouthpiece and bell on the frequencies of the vibrating air column in a trombone can be demonstrated quite readily by first calculating the expected resonant frequencies of a piece of PVC pipe that is the same length as a trombone, then replacing portions of the PVC pipe of the same length with first a cup-shaped mouthpiece and…

  17. Registration of 3D fetal neurosonography and MRI☆

    PubMed Central

    Kuklisova-Murgasova, Maria; Cifor, Amalia; Napolitano, Raffaele; Papageorghiou, Aris; Quaghebeur, Gerardine; Rutherford, Mary A.; Hajnal, Joseph V.; Noble, J. Alison; Schnabel, Julia A.

    2013-01-01

    We propose a method for registration of 3D fetal brain ultrasound with a reconstructed magnetic resonance fetal brain volume. This method, for the first time, allows the alignment of models of the fetal brain built from magnetic resonance images with 3D fetal brain ultrasound, opening possibilities to develop new, prior information based image analysis methods for 3D fetal neurosonography. The reconstructed magnetic resonance volume is first segmented using a probabilistic atlas and a pseudo ultrasound image volume is simulated from the segmentation. This pseudo ultrasound image is then affinely aligned with clinical ultrasound fetal brain volumes using a robust block-matching approach that can deal with intensity artefacts and missing features in the ultrasound images. A qualitative and quantitative evaluation demonstrates good performance of the method for our application, in comparison with other tested approaches. The intensity average of 27 ultrasound images co-aligned with the pseudo ultrasound template shows good correlation with anatomy of the fetal brain as seen in the reconstructed magnetic resonance image. PMID:23969169

  18. Focal Laser Ablation of Prostate Cancer: Feasibility of Magnetic Resonance Imaging-Ultrasound Fusion for Guidance.

    PubMed

    Natarajan, Shyam; Jones, Tonye A; Priester, Alan M; Geoghegan, Rory; Lieu, Patricia; Delfin, Merdie; Felker, Ely; Margolis, Daniel J A; Sisk, Anthony; Pantuck, Allan; Grundfest, Warren; Marks, Leonard S

    2017-10-01

    Focal laser ablation is a potential treatment in some men with prostate cancer. Currently focal laser ablation is performed by radiologists in a magnetic resonance imaging unit (in bore). We evaluated the safety and feasibility of performing focal laser ablation in a urology clinic (out of bore) using magnetic resonance imaging-ultrasound fusion for guidance. A total of 11 men with intermediate risk prostate cancer were enrolled in this prospective, institutional review board approved pilot study. Magnetic resonance imaging-ultrasound fusion was used to guide laser fibers transrectally into regions of interest harboring intermediate risk prostate cancer. Thermal probes were inserted for real-time monitoring of intraprostatic temperatures during laser activation. Multiparametric magnetic resonance imaging (3 Tesla) was done immediately after treatment and at 6 months along with comprehensive fusion biopsy. Ten of 11 patients were successfully treated while under local anesthesia. Mean procedure time was 95 minutes (range 71 to 105). Posttreatment magnetic resonance imaging revealed a confined zone of nonperfusion in all 10 men. Mean zone volume was 4.3 cc (range 2.1 to 6.0). No CTCAE grade 3 or greater adverse events developed and no changes were observed in urinary or sexual function. At 6 months magnetic resonance imaging-ultrasound fusion biopsy of the treatment site showed no cancer in 3 patients, microfocal Gleason 3 + 3 in another 3 and persistent intermediate risk prostate cancer in 4. Focal laser ablation of prostate cancer appears safe and feasible with the patient under local anesthesia in a urology clinic using magnetic resonance imaging-ultrasound fusion for guidance and thermal probes for monitoring. Further development is necessary to refine out of bore focal laser ablation and additional studies are needed to determine appropriate treatment margins and oncologic efficacy. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. Finding the imposter: brain connectivity of lesions causing delusional misidentifications.

    PubMed

    Darby, R Ryan; Laganiere, Simon; Pascual-Leone, Alvaro; Prasad, Sashank; Fox, Michael D

    2017-02-01

    SEE MCKAY AND FURL DOI101093/AWW323 FOR A SCIENTIFIC COMMENTARY ON THIS ARTICLE: Focal brain injury can sometimes lead to bizarre symptoms, such as the delusion that a family member has been replaced by an imposter (Capgras syndrome). How a single brain lesion could cause such a complex disorder is unclear, leading many to speculate that concurrent delirium, psychiatric disease, dementia, or a second lesion is required. Here we instead propose that Capgras and other delusional misidentification syndromes arise from single lesions at unique locations within the human brain connectome. This hypothesis is motivated by evidence that symptoms emerge from sites functionally connected to a lesion location, not just the lesion location itself. First, 17 cases of lesion-induced delusional misidentifications were identified and lesion locations were mapped to a common brain atlas. Second, lesion network mapping was used to identify brain regions functionally connected to the lesion locations. Third, regions involved in familiarity perception and belief evaluation, two processes thought to be abnormal in delusional misidentifications, were identified using meta-analyses of previous functional magnetic resonance imaging studies. We found that all 17 lesion locations were functionally connected to the left retrosplenial cortex, the region most activated in functional magnetic resonance imaging studies of familiarity. Similarly, 16 of 17 lesion locations were functionally connected to the right frontal cortex, the region most activated in functional magnetic resonance imaging studies of expectation violation, a component of belief evaluation. This connectivity pattern was highly specific for delusional misidentifications compared to four other lesion-induced neurological syndromes (P < 0.0001). Finally, 15 lesions causing other types of delusions were connected to expectation violation (P < 0.0001) but not familiarity regions, demonstrating specificity for delusion content. Our results provide potential neuroanatomical correlates for impaired familiarity perception and belief evaluation in patients with delusional misidentifications. More generally, we demonstrate a mechanism by which a single lesion can cause a complex neuropsychiatric syndrome based on that lesion's unique pattern of functional connectivity, without the need for pre-existing or hidden pathology. © The Author (2016). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Finding the imposter: brain connectivity of lesions causing delusional misidentifications

    PubMed Central

    Darby, R Ryan; Laganiere, Simon; Pascual-Leone, Alvaro; Prasad, Sashank; Fox, Michael D

    2017-01-01

    Abstract See McKay and Furl (doi:10.1093/aww323) for a scientific commentary on this article. Focal brain injury can sometimes lead to bizarre symptoms, such as the delusion that a family member has been replaced by an imposter (Capgras syndrome). How a single brain lesion could cause such a complex disorder is unclear, leading many to speculate that concurrent delirium, psychiatric disease, dementia, or a second lesion is required. Here we instead propose that Capgras and other delusional misidentification syndromes arise from single lesions at unique locations within the human brain connectome. This hypothesis is motivated by evidence that symptoms emerge from sites functionally connected to a lesion location, not just the lesion location itself. First, 17 cases of lesion-induced delusional misidentifications were identified and lesion locations were mapped to a common brain atlas. Second, lesion network mapping was used to identify brain regions functionally connected to the lesion locations. Third, regions involved in familiarity perception and belief evaluation, two processes thought to be abnormal in delusional misidentifications, were identified using meta-analyses of previous functional magnetic resonance imaging studies. We found that all 17 lesion locations were functionally connected to the left retrosplenial cortex, the region most activated in functional magnetic resonance imaging studies of familiarity. Similarly, 16 of 17 lesion locations were functionally connected to the right frontal cortex, the region most activated in functional magnetic resonance imaging studies of expectation violation, a component of belief evaluation. This connectivity pattern was highly specific for delusional misidentifications compared to four other lesion-induced neurological syndromes (P < 0.0001). Finally, 15 lesions causing other types of delusions were connected to expectation violation (P < 0.0001) but not familiarity regions, demonstrating specificity for delusion content. Our results provide potential neuroanatomical correlates for impaired familiarity perception and belief evaluation in patients with delusional misidentifications. More generally, we demonstrate a mechanism by which a single lesion can cause a complex neuropsychiatric syndrome based on that lesion’s unique pattern of functional connectivity, without the need for pre-existing or hidden pathology. PMID:28082298

  1. Image-based gradient non-linearity characterization to determine higher-order spherical harmonic coefficients for improved spatial position accuracy in magnetic resonance imaging.

    PubMed

    Weavers, Paul T; Tao, Shengzhen; Trzasko, Joshua D; Shu, Yunhong; Tryggestad, Erik J; Gunter, Jeffrey L; McGee, Kiaran P; Litwiller, Daniel V; Hwang, Ken-Pin; Bernstein, Matt A

    2017-05-01

    Spatial position accuracy in magnetic resonance imaging (MRI) is an important concern for a variety of applications, including radiation therapy planning, surgical planning, and longitudinal studies of morphologic changes to study neurodegenerative diseases. Spatial accuracy is strongly influenced by gradient linearity. This work presents a method for characterizing the gradient non-linearity fields on a per-system basis, and using this information to provide improved and higher-order (9th vs. 5th) spherical harmonic coefficients for better spatial accuracy in MRI. A large fiducial phantom containing 5229 water-filled spheres in a grid pattern is scanned with the MR system, and the positions all the fiducials are measured and compared to the corresponding ground truth fiducial positions as reported from a computed tomography (CT) scan of the object. Systematic errors from off-resonance (i.e., B0) effects are minimized with the use of increased receiver bandwidth (±125kHz) and two acquisitions with reversed readout gradient polarity. The spherical harmonic coefficients are estimated using an iterative process, and can be subsequently used to correct for gradient non-linearity. Test-retest stability was assessed with five repeated measurements on a single scanner, and cross-scanner variation on four different, identically-configured 3T wide-bore systems. A decrease in the root-mean-square error (RMSE) over a 50cm diameter spherical volume from 1.80mm to 0.77mm is reported here in the case of replacing the vendor's standard 5th order spherical harmonic coefficients with custom fitted 9th order coefficients, and from 1.5mm to 1mm by extending custom fitted 5th order correction to the 9th order. Minimum RMSE varied between scanners, but was stable with repeated measurements in the same scanner. The results suggest that the proposed methods may be used on a per-system basis to more accurately calibrate MR gradient non-linearity coefficients when compared to vendor standard corrections. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    PubMed

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 or greater was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of multiparametric magnetic resonance imaging and fusion guided targeted biopsy for clinically significant prostate cancer was 84.6% and 56.7% with a negative likelihood ratio of 0.35 and 0.46, respectively. Multiparametric magnetic resonance imaging alone should not be performed as a triage test due to a substantial number of false-negative cases with clinically significant prostate cancer. Systematic biopsy outperformed fusion guided targeted biopsy. Therefore, it will remain crucial in the diagnostic pathway of prostate cancer. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Combined magnetic resonance, fluorescence, and histology imaging strategy in a human breast tumor xenograft model

    PubMed Central

    Jiang, Lu; Greenwood, Tiffany R.; Amstalden van Hove, Erika R.; Chughtai, Kamila; Raman, Venu; Winnard, Paul T.; Heeren, Ron; Artemov, Dmitri; Glunde, Kristine

    2014-01-01

    Applications of molecular imaging in cancer and other diseases frequently require combining in vivo imaging modalities, such as magnetic resonance and optical imaging, with ex vivo optical, fluorescence, histology, and immunohistochemical (IHC) imaging, to investigate and relate molecular and biological processes to imaging parameters within the same region of interest. We have developed a multimodal image reconstruction and fusion framework that accurately combines in vivo magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI), ex vivo brightfield and fluorescence microscopic imaging, and ex vivo histology imaging. Ex vivo brightfield microscopic imaging was used as an intermediate modality to facilitate the ultimate link between ex vivo histology and in vivo MRI/MRSI. Tissue sectioning necessary for optical and histology imaging required generation of a three-dimensional (3D) reconstruction module for 2D ex vivo optical and histology imaging data. We developed an external fiducial marker based 3D reconstruction method, which was able to fuse optical brightfield and fluorescence with histology imaging data. Registration of 3D tumor shape was pursued to combine in vivo MRI/MRSI and ex vivo optical brightfield and fluorescence imaging data. This registration strategy was applied to in vivo MRI/MRSI, ex vivo optical brightfield/fluorescence, as well as histology imaging data sets obtained from human breast tumor models. 3D human breast tumor data sets were successfully reconstructed and fused with this platform. PMID:22945331

  4. Effects of long-term, low-dose sex hormone replacement therapy on hippocampus and cognition of postmenopausal women of different apoE genotypes.

    PubMed

    Yue, Yun; Hu, Ling; Tian, Qin-jie; Jiang, Jing-mei; Dong, Yi-long; Jin, Zheng-yu; Cheng, Yu-hang; Hong, Xia; Ge, Qin-sheng; Zuo, Ping-ping

    2007-08-01

    To study the effects of long-term, low-dose sex hormone replacement therapy (HRT) on the volume and biochemical changes of the hippocampus in postmenopausal women carrying apolipoprotein E (apoE) gene epsilon3 or epsilon4. Eighty-three postmenopausal women who had used a low dose of HRT for over 4 years were selected as the HRT group, and 99 postmenopausal women with matched age and education were enrolled as the control group. ApoE alleles were analyzed by PCR. Magnetic resonance imaging was performed to determine the volume of the brain hippocampus. Proton magnetic resonance spectroscopy was used to detect the biochemical changes in the anterior cingulate cortex and hippocampus in apoE epsilon4 and epsilon3 carriers. Six common cognitive tests were used to make an overall evaluation of cognitive function. Analysis with the apoE epsilon4 carriers showed that the volume of the hippocampus of the control group were significantly lower than those of the HRT group. The biochemical analysis showed that there was an increase of N-acetylaspartate (NAA)/total creatine (tCr) and a decrease of myoinositol (mI)/tCr in the hippocampus of apoE epsilon4 carriers in the HRT group, compared with the control group. For the apoE epsilon3 carriers, the least squares means (LSMEAN) of the HRT group was higher than that of the control group. This study showed that long-term, low dose HRT might be beneficial for reducing the risk of AD development in vulnerable postmenopausal women. Meanwhile, HRT could increase the LSMEAN of apoE epsilon3 carriers.

  5. Circular Samples as Objects for Magnetic Resonance Imaging - Mathematical Simulation, Experimental Results

    NASA Astrophysics Data System (ADS)

    Frollo, Ivan; Krafčík, Andrej; Andris, Peter; Přibil, Jiří; Dermek, Tomáš

    2015-12-01

    Circular samples are the frequent objects of "in-vitro" investigation using imaging method based on magnetic resonance principles. The goal of our investigation is imaging of thin planar layers without using the slide selection procedure, thus only 2D imaging or imaging of selected layers of samples in circular vessels, eppendorf tubes,.. compulsorily using procedure "slide selection". In spite of that the standard imaging methods was used, some specificity arise when mathematical modeling of these procedure is introduced. In the paper several mathematical models were presented that were compared with real experimental results. Circular magnetic samples were placed into the homogenous magnetic field of a low field imager based on nuclear magnetic resonance. For experimental verification an MRI 0.178 Tesla ESAOTE Opera imager was used.

  6. Magnetic resonance imaging of the knee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mink, J.H.; Reicher, M.A.; Crues, J.V.

    1987-01-01

    Introducing a comprehensive, practical guide to the use of magnetic resonance imaging (MRI) in detecting and evaluating knee disorders and planning arthroscopic surgery) This book integrates MRI findings with pertinent anatomy, physiology, and clinical signs to assist radiologists in selecting imaging protocols and interpreting scans. Detailed chapters focus on magnetic resonance imaging of the menisci and ligaments and evaluation of osteonecrosis, osteochondrosis, and osteochondritis. The authors demonstrate the potential of MRI for diagnosing various knee disorders such as arthritis, fractures, popliteal cysts, synovial disease, plicae, popliteal artery aneurysms, tumors, and bone marrow disorders.

  7. Novel detection schemes of nuclear magnetic resonance and magnetic resonance imaging: applications from analytical chemistry to molecular sensors.

    PubMed

    Harel, Elad; Schröder, Leif; Xu, Shoujun

    2008-01-01

    Nuclear magnetic resonance (NMR) is a well-established analytical technique in chemistry. The ability to precisely control the nuclear spin interactions that give rise to the NMR phenomenon has led to revolutionary advances in fields as diverse as protein structure determination and medical diagnosis. Here, we discuss methods for increasing the sensitivity of magnetic resonance experiments, moving away from the paradigm of traditional NMR by separating the encoding and detection steps of the experiment. This added flexibility allows for diverse applications ranging from lab-on-a-chip flow imaging and biological sensors to optical detection of magnetic resonance imaging at low magnetic fields. We aim to compare and discuss various approaches for a host of problems in material science, biology, and physics that differ from the high-field methods routinely used in analytical chemistry and medical imaging.

  8. Advanced neuroimaging techniques for the term newborn with encephalopathy.

    PubMed

    Chau, Vann; Poskitt, Kenneth John; Miller, Steven Paul

    2009-03-01

    Neonatal encephalopathy is associated with a high risk of morbidity and mortality in the neonatal period and of long-term neurodevelopmental disability in survivors. Advanced magnetic resonance techniques now play a major role in the clinical care of newborns with encephalopathy and in research addressing this important condition. From conventional magnetic resonance imaging, typical patterns of injury have been defined in neonatal encephalopathy. When applied in contemporary cohorts of newborns with encephalopathy, the patterns of brain injury on magnetic resonance imaging distinguish risk factors, clinical presentation, and risk of abnormal outcome. Advanced magnetic resonance techniques such as magnetic resonance spectroscopy, diffusion-weighted imaging, and diffusion tensor imaging provide novel perspectives on neonatal brain metabolism, microstructure, and connectivity. With the application of these imaging tools, it is increasingly apparent that brain injury commonly occurs at or near the time of birth and evolves over the first weeks of life. These observations have complemented findings from trials of emerging strategies of brain protection, such as hypothermia. Application of these advanced magnetic resonance techniques may enable the earliest possible identification of newborns at risk of neurodevelopmental impairment, thereby ensuring appropriate follow-up with rehabilitation and psychoeducational resources.

  9. The Value of Neurosurgical and Intraoperative Magnetic Resonance Imaging and Diffusion Tensor Imaging Tractography in Clinically Integrated Neuroanatomy Modules: A Cross-Sectional Study

    ERIC Educational Resources Information Center

    Familiari, Giuseppe; Relucenti, Michela; Heyn, Rosemarie; Baldini, Rossella; D'Andrea, Giancarlo; Familiari, Pietro; Bozzao, Alessandro; Raco, Antonino

    2013-01-01

    Neuroanatomy is considered to be one of the most difficult anatomical subjects for students. To provide motivation and improve learning outcomes in this area, clinical cases and neurosurgical images from diffusion tensor imaging (DTI) tractographies produced using an intraoperative magnetic resonance imaging apparatus (MRI/DTI) were presented and…

  10. ImagingReso: A Tool for Neutron Resonance Imaging

    DOE PAGES

    Zhang, Yuxuan; Bilheux, Jean -Christophe

    2017-11-01

    ImagingReso is an open-source Python library that simulates the neutron resonance signal for neutron imaging measurements. By defining the sample information such as density, thickness in the neutron path, and isotopic ratios of the elemental composition of the material, this package plots the expected resonance peaks for a selected neutron energy range. Various sample types such as layers of single elements (Ag, Co, etc. in solid form), chemical compounds (UO 3, Gd 2O 3, etc.), or even multiple layers of both types can be plotted with this package. As a result, major plotting features include display of the transmission/attenuation inmore » wavelength, energy, and time scale, and show/hide elemental and isotopic contributions in the total resonance signal.« less

  11. Medical Imaging Field of Magnetic Resonance Imaging: Identification of Specialties within the Field

    ERIC Educational Resources Information Center

    Grey, Michael L.

    2009-01-01

    This study was conducted to determine if specialty areas are emerging in the magnetic resonance imaging (MRI) profession due to advancements made in the medical sciences, imaging technology, and clinical applications used in MRI that would require new developments in education/training programs and national registry examinations. In this…

  12. Pituitary Dysfunction after Blast Traumatic Brain Injury: The UK BIOSAP Study

    PubMed Central

    Baxter, David; Sharp, David J; Feeney, Claire; Papadopoulou, Debbie; Ham, Timothy E; Jilka, Sagar; Hellyer, Peter J; Patel, Maneesh C; Bennett, Alexander N; Mistlin, Alan; McGilloway, Emer; Midwinter, Mark; Goldstone, Anthony P

    2013-01-01

    Objective Pituitary dysfunction is a recognized consequence of traumatic brain injury (TBI) that causes cognitive, psychological, and metabolic impairment. Hormone replacement offers a therapeutic opportunity. Blast TBI (bTBI) from improvised explosive devices is commonly seen in soldiers returning from recent conflicts. We investigated: (1) the prevalence and consequences of pituitary dysfunction following moderate to severe bTBI and (2) whether it is associated with particular patterns of brain injury. Methods Nineteen male soldiers with moderate to severe bTBI (median age = 28.3 years) and 39 male controls with moderate to severe nonblast TBI (nbTBI; median age = 32.3 years) underwent full dynamic endocrine assessment between 2 and 48 months after injury. In addition, soldiers had structural brain magnetic resonance imaging, including diffusion tensor imaging (DTI), and cognitive assessment. Results Six of 19 (32.0%) soldiers with bTBI, but only 1 of 39 (2.6%) nbTBI controls, had anterior pituitary dysfunction (p = 0.004). Two soldiers had hyperprolactinemia, 2 had growth hormone (GH) deficiency, 1 had adrenocorticotropic hormone (ACTH) deficiency, and 1 had combined GH/ACTH/gonadotrophin deficiency. DTI measures of white matter structure showed greater traumatic axonal injury in the cerebellum and corpus callosum in those soldiers with pituitary dysfunction than in those without. Soldiers with pituitary dysfunction after bTBI also had a higher prevalence of skull/facial fractures and worse cognitive function. Four soldiers (21.1%) commenced hormone replacement(s) for hypopituitarism. Interpretation We reveal a high prevalence of anterior pituitary dysfunction in soldiers suffering moderate to severe bTBI, which was more frequent than in a matched group of civilian moderate to severe nbTBI subjects. We recommend that all patients with moderate to severe bTBI should routinely have comprehensive assessment of endocrine function. Ann Neurol 2013;74:527–536 PMID:23794460

  13. Osteoarthritis year in review 2016: imaging.

    PubMed

    Boesen, M; Ellegaard, K; Henriksen, M; Gudbergsen, H; Hansen, P; Bliddal, H; Bartels, E M; Riis, R G

    2017-02-01

    The current narrative review covers original research related to imaging in osteoarthritis (OA) in humans published in English between April 1st 2015 and March 31st 2016, in peer reviewed journals available in Medline via PubMed (http://www.ncbi.nlm.nih.gov/pubmed/). Relevant studies in humans, subjectively decided by the authors, contributing significantly to the OA imaging field, were selected from an extensive Medline search using the terms "Osteoarthritis" in combination with "MRI", "Imaging", "Radiography", "X-rays", "Ultrasound", "Computed tomography", "Nuclear medicine", "PET-CT", "PET-MRI", "Scintigraphy", "SPECT". Publications were sorted according to relevance for the OA imaging research community with an emphasis on high impact special interest journals using the software for systematic reviews www.covidence.org. An overview of newly published studies compared to studies reported previous years is presented, followed by a review of selected imaging studies of primarily knee, hip and hand OA focussing on (1) results for detection of OA and OA-related pathology (2) studies dealing with treatments and (3) studies focussing on prognosis of disease progression or joint replacement. A record high number of 1420 articles were published, among others, of new technologies and tools for improved morphological and pathophysiological understanding of OA-related changes in joints. Also, imaging data were presented of monitoring treatment effect and prognosis of OA progression, primarily using established radiographic, magnetic resonance imaging (MRI), and ultrasound (US) methods. Imaging continues to play an important role in OA research, where several exciting new technologies and computer aided analysis methods are emerging to complement the conventional imaging approaches. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  14. Task-oriented lossy compression of magnetic resonance images

    NASA Astrophysics Data System (ADS)

    Anderson, Mark C.; Atkins, M. Stella; Vaisey, Jacques

    1996-04-01

    A new task-oriented image quality metric is used to quantify the effects of distortion introduced into magnetic resonance images by lossy compression. This metric measures the similarity between a radiologist's manual segmentation of pathological features in the original images and the automated segmentations performed on the original and compressed images. The images are compressed using a general wavelet-based lossy image compression technique, embedded zerotree coding, and segmented using a three-dimensional stochastic model-based tissue segmentation algorithm. The performance of the compression system is then enhanced by compressing different regions of the image volume at different bit rates, guided by prior knowledge about the location of important anatomical regions in the image. Application of the new system to magnetic resonance images is shown to produce compression results superior to the conventional methods, both subjectively and with respect to the segmentation similarity metric.

  15. Spanish Pacemaker Registry. Twelfth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2014).

    PubMed

    Cano Pérez, Óscar; Pombo Jiménez, Marta; Coma Samartín, Raúl

    2015-12-01

    This report describes the results of the analysis of pacemaker implant and replacement data submitted to the Spanish Pacemaker Registry in 2014, with special reference to pacing mode selection. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. Information was received from 117 hospitals, with a total of 12 358 cards, representing 34% of estimated activity. Use of conventional generators and resynchronization devices was 784 and 64.4 units per million population, respectively. The mean age of patients receiving an implant was 77.3 years. Men received 59% of implants and 56.4% of replacements. Most patients receiving generator implants and replacements were in the age range 80 to 89 years. Most endocardial leads used were bipolar, and 84.2% had an active fixation system. Pacing was in VVI/R mode despite being in sinus rhythm in 24.7% of patients with sick sinus syndrome and 24% of those with atrioventricular block. The use of pacemaker generators and resynchronization devices per million population continued to increase. Most implanted leads had active fixation and approximately 20% had magnetic resonance imaging protection. Age and sex directly influenced pacing mode selection, which could have been improved in more than 20% of cases. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  16. Spider Silk: From Protein-Rich Gland Fluids to Diverse Biopolymer Fibers

    DTIC Science & Technology

    2016-01-06

    characterize the protein-rich fluid in the various spider silk producing glands. We have been using a battery of magnetic resonance methods including...solution and solid-state nuclear magnetic resonance (NMR) and micro imaging (MRI) in combination with wide angle and small angle X-ray diffraction...range of magnetic resonance methods. We successfully developed magnetic resonance imaging (MRI) techniques with localized spectroscopy to probe the silk

  17. Tracking stem cell migration and survival in brain injury: current approaches and future prospects.

    PubMed

    Darkazalli, Ali; Levenson, Cathy W

    2012-10-01

    In recent years, stem cell-mediated therapies have gained considerable ground as potential treatments for a wide variety of brain pathologies including traumatic brain injury, stroke and neurodegenerative diseases. Despite extensive preclinical studies, many of these therapies have not been fully translated into viable clinical approaches. This is partly due to our inability to reliably track and monitor transplanted stem cells longitudinally over long periods of time in vivo. In this review, we discuss the predominant histological cell tracing methodologies, such as immunohistochemistry, and fluorescent cellular dyes and proteins, and compare them to emerging cellular imaging technologies. We show that advances in magnetic resonance imaging (MRI) have resulted in opportunities to use this technology to further our understanding of stem cell characteristics and behaviors in vivo. While MRI may not completely replace conventional cell tracking methods in pre-clinical, mechanistic work, it is clear that it has the potential to function as a powerful diagnostic tool for tracking stem cell migration and survival as well as for evaluating the efficacy of stem cell-mediated therapies.

  18. In vivo NMR microscopy allows short-term serial assessment of multiple skeletal implications of corticosteroid exposure

    PubMed Central

    Takahashi, Masaya; Wehrli, Felix W.; Hilaire, Luna; Zemel, Babette S.; Hwang, Scott N.

    2002-01-01

    Corticosteroids are in widespread clinical use but are known to have adverse skeletal side effects. Moreover, it is not known how soon these effects become apparent. Here, we describe a longitudinal approach to evaluate the short-term implications of excess corticosteroid exposure by quantitative in vivo magnetic resonance imaging and spectroscopy in conjunction with digital image processing and analysis in a rabbit model. Two-week treatment with dexamethasone induced a significant reduction in trabecular bone volume, which occurred at the expense of uniform trabecular thinning without affecting network architecture. Paralleling the loss in bone volume was conversion of hematopoietic to yellow marrow in the femoral metaphysis and atrophy of the femoral epiphyseal growth plate. This work demonstrates that detailed quantitative morphometric and physiological information can be obtained noninvasively at multiple skeletal locations. The method is likely to eventually replace invasive histomorphometry in that it obviates the need to sacrifice groups of animals at multiple time points. Finally, this work, which was performed on a clinical scanner, has implications for evaluating patients on high-dose steroid treatment. PMID:11904367

  19. Autoimmune hyperthyroidism due to secondary adrenal insufficiency: resolution with glucocorticoids.

    PubMed

    Skamagas, Maria; Geer, Eliza B

    2011-01-01

    To describe the course of autoimmune hyperthyroid disease in a patient with corticotropin (ACTH) deficiency treated with glucocorticoids. We report the clinical presentation, laboratory data, imaging studies, and management of a patient with weight loss, fatigue, apathy, hallucinations, and arthritis. Autoimmune hyperthyroidism (positive thyroperoxidase and thyroglobulin antibodies and borderline positive thyrotropin receptor antibody) was diagnosed in a 71-year-old woman. New psychotic symptoms prompted brain magnetic resonance imaging, which revealed a partially empty sella. Undetectable morning cortisol, undetectable ACTH, and failure to stimulate cortisol with synthetic ACTH (cosyntropin 250 mcg) secured the diagnosis of long-standing secondary adrenal insufficiency. Hydrocortisone replacement improved the patient's symptoms, resolved the thyroid disease, and decreased thyroid antibody titers. In retrospect, the patient recalled severe postpartum hemorrhage requiring blood transfusion at age 38 years. A Sheehan event probably occurred 33 years before the patient presented with corticotropin deficiency. Hyperthyroidism accelerated cortisol metabolism and provoked symptoms of adrenal insufficiency. The hypocortisolemic state may precipitate hyperimmunity and autoimmune thyroid disease. Rapid resolution of hyperthyroidism and decreased thyroid antibody titers with glucocorticoid treatment support this hypothesis.

  20. NASA Tech Briefs, April 2006

    NASA Technical Reports Server (NTRS)

    2006-01-01

    The topics covered include: 1) Replaceable Sensor System for Bioreactor Monitoring; 2) Unitary Shaft-Angle and Shaft-Speed Sensor Assemblies; 3) Arrays of Nano Tunnel Junctions as Infrared Image Sensors; 4) Catalytic-Metal/PdO(sub x)/SiC Schottky-Diode Gas Sensors; 5) Compact, Precise Inertial Rotation Sensors for Spacecraft; 6) Universal Controller for Spacecraft Mechanisms; 7) The Flostation - an Immersive Cyberspace System; 8) Algorithm for Aligning an Array of Receiving Radio Antennas; 9) Single-Chip T/R Module for 1.2 GHz; 10) Quantum Entanglement Molecular Absorption Spectrum Simulator; 11) FuzzObserver; 12) Internet Distribution of Spacecraft Telemetry Data; 13) Semi-Automated Identification of Rocks in Images; 14) Pattern-Recognition Algorithm for Locking Laser Frequency; 15) Designing Cure Cycles for Matrix/Fiber Composite Parts; 16) Controlling Herds of Cooperative Robots; 17) Modification of a Limbed Robot to Favor Climbing; 18) Vacuum-Assisted, Constant-Force Exercise Device; 19) Production of Tuber-Inducing Factor; 20) Quantum-Dot Laser for Wavelengths of 1.8 to 2.3 micron; 21) Tunable Filter Made From Three Coupled WGM Resonators; and 22) Dynamic Pupil Masking for Phasing Telescope Mirror Segments.

  1. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    PubMed

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Functional Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  3. [Latest progress on diagnosis and treatment of glenohumeral instability].

    PubMed

    Zhao, Gang; Liu, Yu-Jie

    2014-02-01

    As a common and frequently-occurring disease,glenohumeral instability is become one of disease which restrict upper limb activity. The diagnosis of this disease is easy, but it is very difficult to assess the degree of periarticular soft tissue injuries. With the development of magnetic resonance imaging and arthroscopy, MRA become the gold standard for evaluation of glenoid labrum, joint capsule and ligaments injury. The traditional manual reduction is a fast, simple method, but often can cause adverse consequences,such as rotator cuff tear,ligament relaxation,and habitual dislocation. Open operation can rebuild stability of joint,but with many new treatment methods,especially the arthroscopic reconstruction has gradually replaced the open operation, and become the mainstream trend, but for the long-term effect of capsular tightening surgery, rotator cuff gap closure is not clear,it is need further follow-up observation.

  4. Applied optics. Multiwavelength achromatic metasurfaces by dispersive phase compensation.

    PubMed

    Aieta, Francesco; Kats, Mikhail A; Genevet, Patrice; Capasso, Federico

    2015-03-20

    The replacement of bulk refractive optical elements with diffractive planar components enables the miniaturization of optical systems. However, diffractive optics suffers from large chromatic aberrations due to the dispersion of the phase accumulated by light during propagation. We show that this limitation can be overcome with an engineered wavelength-dependent phase shift imparted by a metasurface, and we demonstrate a design that deflects three wavelengths by the same angle. A planar lens without chromatic aberrations at three wavelengths is also presented. Our designs are based on low-loss dielectric resonators, which introduce a dense spectrum of optical modes to enable dispersive phase compensation. The suppression of chromatic aberrations in metasurface-based planar photonics will find applications in lightweight collimators for displays, as well as chromatically corrected imaging systems. Copyright © 2015, American Association for the Advancement of Science.

  5. [Pure trigeminal motor neuropathy presenting with temporo-mandibular joint dysfunction in a patient with HIV and HCV infections].

    PubMed

    Anheim, M; Echaniz-Laguna, A; Rey, D; Tranchant, C

    2006-01-01

    Pure trigeminal motor neuropathy (PTMN) is a rarely described condition. We report the case of a 41-year-old woman infected with the human immunodeficiency virus (HIV1) and hepatitis C virus who presented with weakness of left temporalis and masseter muscles and painful left temporomandibular joint dysfunction (TMD) a few months after cerebral toxoplasmosis revealing acquired immunodeficiency syndrome (AIDS). Magnetic resonance imaging revealed severe wasting and fat replacement of the left temporalis, pterygoid and masseter muscles and showed neither abnormalities in the left motor nucleus of the trigeminal nerve nor compression of the left trigeminal nerve. Electromyographic examination gave evidence of denervation in the left temporalis, masseter and pterygoid muscles and blink reflex studies were normal, confirming the diagnosis of PTMN which was probably secondary to HIV and HCV co-infection.

  6. In Vivo Application of Proton-Electron Double-Resonance Imaging

    PubMed Central

    Kishimoto, Shun; Krishna, Murali C.; Khramtsov, Valery V.; Utsumi, Hideo

    2018-01-01

    Abstract Significance: Proton-electron double-resonance imaging (PEDRI) employs electron paramagnetic resonance irradiation with low-field magnetic resonance imaging so that the electron spin polarization is transferred to nearby protons, resulting in higher signals. PEDRI provides information about free radical distribution and, indirectly, about the local microenvironment such as partial pressure of oxygen (pO2), tissue permeability, redox status, and acid-base balance. Recent Advances: Local acid-base balance can be imaged by exploiting the different resonance frequency of radical probes between R and RH+ forms. Redox status can also be imaged by using the loss of radical-related signal after reduction. These methods require optimized radical probes and pulse sequences. Critical Issues: High-power radio frequency irradiation is needed for optimum signal enhancement, which may be harmful to living tissue by unwanted heat deposition. Free radical probes differ depending on the purpose of PEDRI. Some probes are less effective for enhancing signal than others, which can reduce image quality. It is so far not possible to image endogenous radicals by PEDRI because low concentrations and broad line widths of the radicals lead to negligible signal enhancement. Future Directions: PEDRI has similarities with electron paramagnetic resonance imaging (EPRI) because both techniques observe the EPR signal, directly in the case of EPRI and indirectly with PEDRI. PEDRI provides information that is vital to research on homeostasis, development of diseases, or treatment responses in vivo. It is expected that the development of new EPR techniques will give insights into novel PEDRI applications and vice versa. Antioxid. Redox Signal. 28, 1345–1364. PMID:28990406

  7. Proximal Bright Vessel Sign on Arterial Spin Labeling Magnetic Resonance Imaging in Acute Cardioembolic Cerebral Infarction.

    PubMed

    Kato, Ayumi; Shinohara, Yuki; Kuya, Keita; Sakamoto, Makoto; Kowa, Hisanori; Ogawa, Toshihide

    2017-07-01

    The congestion of spin-labeled blood at large-vessel occlusion can present as hyperintense signals on perfusion magnetic resonance imaging with 3-dimensional pseudo-continuous arterial spin labeling (proximal bright vessel sign). The purpose of this study was to clarify the difference between proximal bright vessel sign and susceptibility vessel sign in acute cardioembolic cerebral infarction. Forty-two patients with cardioembolic cerebral infarction in the anterior circulation territory underwent magnetic resonance imaging including diffusion-weighted imaging, 3-dimensional pseudo-continuous arterial spin labeling perfusion magnetic resonance imaging, T2*-weighted imaging, and 3-dimensional time-of-flight magnetic resonance angiography using a 3-T magnetic resonance scanner. Visual assessments of proximal bright vessel sign and the susceptibility vessel sign were performed by consensus of 2 experienced neuroradiologists. The relationship between these signs and the occlusion site of magnetic resonance angiography was also investigated. Among 42 patients with cardioembolic cerebral infarction, 24 patients showed proximal bright vessel sign (57.1%) and 25 showed susceptibility vessel sign (59.5%). There were 19 cases of proximal bright vessel sign and susceptibility vessel sign-clear, 12 cases of proximal bright vessel sign and susceptibility vessel sign-unclear, and 11 mismatched cases. Four out of 6 patients with proximal bright vessel sign-unclear and susceptibility vessel sign-clear showed distal middle cerebral artery occlusion, and 2 out of 5 patients with proximal bright vessel sign-clear and susceptibility vessel sign-unclear showed no occlusion on magnetic resonance angiography. Proximal bright vessel sign is almost compatible with susceptibility vessel sign in patients with cardioembolic cerebral infarction. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. Magnetic resonance angiography detection of abnormal carotid artery plaque in patients with cryptogenic stroke.

    PubMed

    Gupta, Ajay; Gialdini, Gino; Lerario, Michael P; Baradaran, Hediyeh; Giambrone, Ashley; Navi, Babak B; Marshall, Randolph S; Iadecola, Costantino; Kamel, Hooman

    2015-06-15

    Magnetic resonance imaging of carotid plaque can aid in stroke risk stratification in patients with carotid stenosis. However, the prevalence of complicated carotid plaque in patients with cryptogenic stroke is uncertain, especially as assessed by plaque imaging techniques routinely included in acute stroke magnetic resonance imaging protocols. We assessed whether the magnetic resonance angiography-defined presence of intraplaque high-intensity signal (IHIS), a marker of intraplaque hemorrhage, is associated with ipsilateral cryptogenic stroke. Cryptogenic stroke patients with magnetic resonance imaging evidence of unilateral anterior circulation infarction and without hemodynamically significant (≥50%) stenosis of the cervical carotid artery were identified from a prospective stroke registry at a tertiary-care hospital. High-risk plaque was assessed by evaluating for IHIS on routine magnetic resonance angiography source images using a validated technique. To compare the presence of IHIS on the ipsilateral versus contralateral side within individual patients, we used McNemar's test for correlated proportions. A total of 54 carotid arteries in 27 unique patients were included. A total of 6 patients (22.2%) had IHIS-positive nonstenosing carotid plaque ipsilateral to the side of ischemic stroke compared to 0 patients who had IHIS-positive carotid plaques contralateral to the side of stroke (P=0.01). Stroke severity measures, diagnostic evaluations, and prevalence of vascular risk factors were not different between the IHIS-positive and IHIS-negative groups. Our findings suggest that a proportion of strokes classified as cryptogenic may be mechanistically related to complicated, nonhemodynamically significant cervical carotid artery plaque that can easily be detected by routine magnetic resonance imaging/magnetic resonance angiography acute stroke protocols. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. [Magnetic Resonance Imaging Conversion Predictors of Clinically Isolated Syndrome to Multiple Sclerosis].

    PubMed

    Peixoto, Sara; Abreu, Pedro

    2016-11-01

    Clinically isolated syndrome may be the first manifestation of multiple sclerosis, a chronic demyelinating disease of the central nervous system, and it is defined by a single clinical episode suggestive of demyelination. However, patients with this syndrome, even with long term follow up, may not develop new symptoms or demyelinating lesions that fulfils multiple sclerosis diagnostic criteria. We reviewed, in clinically isolated syndrome, what are the best magnetic resonance imaging findings that may predict its conversion to multiple sclerosis. A search was made in the PubMed database for papers published between January 2010 and June 2015 using the following terms: 'clinically isolated syndrome', 'cis', 'multiple sclerosis', 'magnetic resonance imaging', 'magnetic resonance' and 'mri'. In this review, the following conventional magnetic resonance imaging abnormalities found in literature were included: lesion load, lesion location, Barkhof's criteria and brain atrophy related features. The non conventional magnetic resonance imaging techniques studied were double inversion recovery, magnetization transfer imaging, spectroscopy and diffusion tensor imaging. The number and location of demyelinating lesions have a clear role in predicting clinically isolated syndrome conversion to multiple sclerosis. On the other hand, more data are needed to confirm the ability to predict this disease development of non conventional techniques and remaining neuroimaging abnormalities. In forthcoming years, in addition to the established predictive value of the above mentioned neuroimaging abnormalities, different clinically isolated syndrome neuroradiological findings may be considered in multiple sclerosis diagnostic criteria and/or change its treatment recommendations.

  10. High resolution T2(*)-weighted Magnetic Resonance Imaging at 3 Tesla using PROPELLER-EPI.

    PubMed

    Krämer, Martin; Reichenbach, Jürgen R

    2014-05-01

    We report the application of PROPELLER-EPI for high resolution T2(*)-weighted imaging with sub-millimeter in-plane resolution on a clinical 3 Tesla scanner. Periodically rotated blades of a long-axis PROPELLER-EPI sequence were acquired with fast gradient echo readout and acquisition matrix of 320 × 50 per blade. Images were reconstructed by using 2D-gridding, phase and geometric distortion correction and compensation of resonance frequency drifts that occurred during extended measurements. To characterize these resonance frequency offsets, short FID calibration measurements were added to the PROPELLER-EPI sequence. Functional PROPELLER-EPI was performed with volunteers using a simple block design of right handed finger tapping. Results indicate that PROPELLER-EPI can be employed for fast, high resolution T2(*)-weighted imaging provided geometric distortions and possible resonance frequency drifts are properly corrected. Even small resonance frequency drifts below 10 Hz as well as non-corrected geometric distortions degraded image quality substantially. In the initial fMRI experiment image quality and signal-to-noise ratio was sufficient for obtaining high resolution functional activation maps. Copyright © 2014. Published by Elsevier GmbH.

  11. Liver Function Assessment by Magnetic Resonance Imaging.

    PubMed

    Ünal, Emre; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver function assessment by hepatocyte-specific contrast-enhanced magnetic resonance imaging is becoming a new biomarker. Liver function can be assessed by T1 mapping (reduction rate) and signal intensity measurement (relative enhancement ratio) before and after GD-EOB-DTPA (gadoxetic acid) administration, as alternative to Tc-99m galactosyl serum albumin scintigraphy, 99m Tc-labeled mebrofenin scintigraphy, and indocyanine green clearance test. Magnetic resonance imaging assessment of liver function can enable diagnosis of cirrhosis, nonalcoholic fatty liver disease associated fibrosis and steatohepatitis, primary sclerosing cholangitis, toxic hepatitis, and chemotherapy and radiotherapy-related changes, which may be only visible on hepatobiliary phase images. Simple visual assessment of signal intensity at hepatobiliary phase images is important for the diagnosis of different patterns of liver dysfunction including diffuse, lobar, segmental, and subsegmental forms. Furthermore, preoperative assessment of liver function is feasible before oncologic hepatic surgery, which may be important to prevent posthepatectomy liver failure and to estimate future remnant volume. Functional magnetic resonance cholangiography obtained by T1-weighted images at hepatobiliary phase can allow diagnosis of acalculous cholecystitis, biliary leakage, bile reflux to the stomach, sphincter of oddi dysfunction, and lesions with communication to biliary tree. Functional information can be easily obtained when Gd-EOB-DTPA is used for liver magnetic resonance imaging. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Magnetic resonance image guided transurethral ultrasound prostate ablation: a preclinical safety and feasibility study with 28-day followup.

    PubMed

    Burtnyk, Mathieu; Hill, Tracy; Cadieux-Pitre, Heather; Welch, Ian

    2015-05-01

    We determine the safety and feasibility of magnetic resonance image guided transurethral ultrasound prostate ablation using active temperature feedback control in a preclinical canine model with 28-day followup. After a long acclimatization period we performed ultrasound treatment in 8 subjects using the magnetic resonance image guided TULSA-PRO™ transurethral ultrasound prostate ablation system. Comprehensive examinations and observations were done before and throughout the 28-day followup, including assessment of clinically significant treatment related adverse events. In addition to gross pathology evaluation, extensive histopathological analysis was done to assess cell kill inside and outside the prostate. We evaluated prostate conformal heating by comparing the spatial difference between the treatment plan and the 55C isotherm measured on magnetic resonance imaging thermometry acquired during treatment. These findings were confirmed on contrast enhanced magnetic resonance imaging immediately after treatment and at 28 days. Clinically there were no adverse events in any of the 8 subjects throughout the 28-day followup. All subjects had normal urinary and bowel function. Gross necropsy and histology confirmed that the intended thermal cell kill was confined to the prostate. No surrounding tissue was damaged, including the rectum and the external urinary sphincter. Conformal heating was achieved with an average -0.9 mm accuracy and 0.9 mm precision. Contrast enhanced magnetic resonance imaging and histological analysis confirmed tissue ablation in targeted areas of the prostate. Urethral tissue was spared from thermal damage. Magnetic resonance image guided transurethral ultrasound is a safe, feasible procedure for accurate and precise conformal thermal ablation of prostate tissue, as demonstrated in a preclinical model with 28-day followup. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Herpin effective media resonant underlayers and resonant overlayer designs for ultra-high NA interference lithography.

    PubMed

    Bourke, Levi; Blaikie, Richard J

    2017-12-01

    Dielectric waveguide resonant underlayers are employed in ultra-high NA interference photolithography to effectively double the depth of field. Generally a single high refractive index waveguiding layer is employed. Here multilayer Herpin effective medium methods are explored to develop equivalent multilayer waveguiding layers. Herpin equivalent resonant underlayers are shown to be suitable replacements provided at least one layer within the Herpin trilayer supports propagating fields. In addition, a method of increasing the intensity incident upon the photoresist using resonant overlayers is also developed. This method is shown to greatly enhance the intensity within the photoresist making the use of thicker, safer, non-absorbing, low refractive index matching liquids potentially suitable for large-scale applications.

  14. Magnetic resonance imaging for staging and treatment planning in cervical cancer.

    PubMed

    López-Carballeira, A; Baleato-González, S; García-Figueiras, R; Otero-Estévez, I; Villalba-Martín, C

    2016-01-01

    To review the key points that are essential for the correct staging of cervical cancer by magnetic resonance imaging. Magnetic resonance imaging is the method of choice for locoregional staging of cervical cancer. Thorough evaluation of prognostic factors such as tumor size, invasion of adjacent structures, and the presence of lymph node metastases is fundamental for planning appropriate treatment. Copyright © 2015 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Magnetic resonance imaging of cartilage repair.

    PubMed

    Potter, Hollis G; Chong, Le Roy; Sneag, Darryl B

    2008-12-01

    Magnetic resonance imaging is an important noninvasive modality in characterizing cartilage morphology, biochemistry, and function. It serves as a valuable objective outcome measure in diagnosing pathology at the time of initial injury, guiding surgical planning, and evaluating postsurgical repair. This article reviews the current literature addressing the recent advances in qualitative and quantitative magnetic resonance imaging techniques in the preoperative setting, and in patients who have undergone cartilage repair techniques such as microfracture, autologous cartilage transplantation, or osteochondral transplantation.

  16. Parallel image-acquisition in continuous-wave electron paramagnetic resonance imaging with a surface coil array: Proof-of-concept experiments

    NASA Astrophysics Data System (ADS)

    Enomoto, Ayano; Hirata, Hiroshi

    2014-02-01

    This article describes a feasibility study of parallel image-acquisition using a two-channel surface coil array in continuous-wave electron paramagnetic resonance (CW-EPR) imaging. Parallel EPR imaging was performed by multiplexing of EPR detection in the frequency domain. The parallel acquisition system consists of two surface coil resonators and radiofrequency (RF) bridges for EPR detection. To demonstrate the feasibility of this method of parallel image-acquisition with a surface coil array, three-dimensional EPR imaging was carried out using a tube phantom. Technical issues in the multiplexing method of EPR detection were also clarified. We found that degradation in the signal-to-noise ratio due to the interference of RF carriers is a key problem to be solved.

  17. Medical image segmentation using 3D MRI data

    NASA Astrophysics Data System (ADS)

    Voronin, V.; Marchuk, V.; Semenishchev, E.; Cen, Yigang; Agaian, S.

    2017-05-01

    Precise segmentation of three-dimensional (3D) magnetic resonance imaging (MRI) image can be a very useful computer aided diagnosis (CAD) tool in clinical routines. Accurate automatic extraction a 3D component from images obtained by magnetic resonance imaging (MRI) is a challenging segmentation problem due to the small size objects of interest (e.g., blood vessels, bones) in each 2D MRA slice and complex surrounding anatomical structures. Our objective is to develop a specific segmentation scheme for accurately extracting parts of bones from MRI images. In this paper, we use a segmentation algorithm to extract the parts of bones from Magnetic Resonance Imaging (MRI) data sets based on modified active contour method. As a result, the proposed method demonstrates good accuracy in a comparison between the existing segmentation approaches on real MRI data.

  18. The Correlation Between a Short-term Conventional Electroencephalography in the First Day of Life and Brain Magnetic Resonance Imaging in Newborns Undergoing Hypothermia for Hypoxic-Ischemic Encephalopathy.

    PubMed

    Obeid, Rawad; Sogawa, Yoshimi; Gedela, Satyanarayana; Naik, Monica; Lee, Vince; Telesco, Richard; Wisnowski, Jessica; Magill, Christine; Painter, Michael J; Panigrahy, Ashok

    2017-02-01

    Electroencephalograph recorded in the first day of life in newborns treated with hypothermia for hypoxic-ischemic encephalopathy could be utilized as a predictive tool for the severity of brain injury on magnetic resonance imaging and mortality. We analyzed newborns who were admitted for therapeutic hypothermia due to hypoxic-ischemic encephalopathy. All enrolled infants underwent encephalography within the first 24 hours of life and underwent brain magnetic resonance imaging after rewarming. All encephalographs were independently reviewed for background amplitude, continuity, and variability. Brain injury determined by magnetic resonance imaging was scored using methods described by Bonifacio et al. Forty-one newborns were included in the study. Each encephalograph variable correlated significantly with the severity of injury on brain magnetic resonance imaging (P < 0.001 for each). The overall encephalograph severity estimated as mild, moderate, and severe also correlated with injury (P < 0.001). Each encephalograph variable correlated with mortality (P < 0.001 for each) and also the overall encephalograph severity (P < 0.001). Severity of electrographic findings on encephalograph in the first day of life during therapeutic hypothermia for hypoxic-ischemic encephalopathy correlated with the extent of injury on brain magnetic resonance imaging. This information may be useful for families and aid guide clinical decision making. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Tutte polynomial in functional magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    García-Castillón, Marlly V.

    2015-09-01

    Methods of graph theory are applied to the processing of functional magnetic resonance images. Specifically the Tutte polynomial is used to analyze such kind of images. Functional Magnetic Resonance Imaging provide us connectivity networks in the brain which are represented by graphs and the Tutte polynomial will be applied. The problem of computing the Tutte polynomial for a given graph is #P-hard even for planar graphs. For a practical application the maple packages "GraphTheory" and "SpecialGraphs" will be used. We will consider certain diagram which is depicting functional connectivity, specifically between frontal and posterior areas, in autism during an inferential text comprehension task. The Tutte polynomial for the resulting neural networks will be computed and some numerical invariants for such network will be obtained. Our results show that the Tutte polynomial is a powerful tool to analyze and characterize the networks obtained from functional magnetic resonance imaging.

  20. Numerical study of remote detection outside the magnet with travelling wave Magnetic Resonance Imaging at 3T

    NASA Astrophysics Data System (ADS)

    López, M.; Vázquez, F.; Solís-Nájera, S.; Rodriguez, A. O.

    2015-01-01

    The use of the travelling wave approach for high magnetic field magnetic resonance imaging has been used recently with very promising results. This approach offer images one with greater field-of-view and a reasonable signal-to-noise ratio using a circular waveguide. This scheme has been proved to be successful at 7 T and 9.4 T with whole-body imager. Images have also been acquired with clinical magnetic resonance imaging systems whose resonant frequencies were 64 MHz and 128 MHz. These results motivated the use of remote detection of the magnetic resonance signal using a parallel-plate waveguide together with 3 T clinical scanners, to acquired human leg images. The cut-off frequency of this waveguide is zero for the principal mode, allowing us to overcome the barrier of transmitting waves at lower frequency than 300 MHz or 7 T for protons. These motivated the study of remote detection outside the actual magnet. We performed electromagnetic field simulations of a parallel-plate waveguide and a phantom. The signal transmission was done at 128 MHz and using a circular surface coil located almost 200 cm away for the magnet isocentre. Numerical simulations demonstrated that the magnetic field of the principal mode propagate inside a waveguide outside the magnet. Numerical results were compared with previous experimental-acquired image data under similar conditions.

  1. Nuclear Magnetic Resonance Technology for Medical Studies.

    ERIC Educational Resources Information Center

    Budinger, Thomas F.; Lauterbur, Paul C.

    1984-01-01

    Reports on the status of nuclear magnetic resonance (NMR) from theoretical and clinical perspectives, reviewing NMR theory and relaxation parameters relevant to NMR imaging. Also reviews literature related to modern imaging strategies, signal-to-noise ratio, contrast agents, in vivo spectroscopy, spectroscopic imaging, clinical applications, and…

  2. Towards Single Biomolecule Imaging via Optical Nanoscale Magnetic Resonance Imaging.

    PubMed

    Boretti, Alberto; Rosa, Lorenzo; Castelletto, Stefania

    2015-09-09

    Nuclear magnetic resonance (NMR) spectroscopy is a physical marvel in which electromagnetic radiation is charged and discharged by nuclei in a magnetic field. In conventional NMR, the specific nuclei resonance frequency depends on the strength of the magnetic field and the magnetic properties of the isotope of the atoms. NMR is routinely utilized in clinical tests by converting nuclear spectroscopy in magnetic resonance imaging (MRI) and providing 3D, noninvasive biological imaging. While this technique has revolutionized biomedical science, measuring the magnetic resonance spectrum of single biomolecules is still an intangible aspiration, due to MRI resolution being limited to tens of micrometers. MRI and NMR have, however, recently greatly advanced, with many breakthroughs in nano-NMR and nano-MRI spurred by using spin sensors based on an atomic impurities in diamond. These techniques rely on magnetic dipole-dipole interactions rather than inductive detection. Here, novel nano-MRI methods based on nitrogen vacancy centers in diamond are highlighted, that provide a solution to the imaging of single biomolecules with nanoscale resolution in-vivo and in ambient conditions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Magnetic resonance imaging findings in Ménière's disease.

    PubMed

    Patel, V A; Oberman, B S; Zacharia, T T; Isildak, H

    2017-07-01

    To identify and evaluate cranial magnetic resonance imaging findings associated with Ménière's disease. Seventy-eight patients with a documented diagnosis of Ménière's disease and 35 controls underwent 1.5 T or 3 T magnetic resonance imaging of the brain. Patients also underwent otological, vestibular and audiometric examinations. Lack of visualisation of the left and right vestibular aqueducts was identified as statistically significant amongst Ménière's disease patients (left, p = 0.0001, odds ratio = 0.02; right, p = 0.0004, odds ratio = 0.03). Both vestibular aqueducts were of abnormal size in the Ménière's disease group, albeit with left-sided significance (left, p = 0.008, odds ratio = 10.91; right, p = 0.49, odds ratio = 2.47). Lack of vestibular aqueduct visualisation on magnetic resonance imaging was statistically significant in Ménière's disease patients compared to the general population. The study findings suggest that magnetic resonance imaging can be useful to rule out retrocochlear pathology and provide radiological data to support the clinical diagnosis of Ménière's disease.

  4. Noninvasive diagnosis of right-sided extracardiac conduit obstruction by combined magnetic resonance imaging and continuous-wave Doppler echocardiography.

    PubMed

    Canter, C E; Gutierrez, F R; Molina, P; Hartmann, A F; Spray, T L

    1991-04-01

    Right-sided extracardiac conduits are frequently complicated by obstruction over time. We compared the utility of two-dimensional and Doppler echocardiography and magnetic resonance imaging in the diagnosis of postoperative right-sided obstruction with cardiac catheterization and angiography in 10 patients with xenograft or homograft conduits. Correlation (r = 0.95) between continuous-wave Doppler estimates and catheter pullback pressure gradients across the conduits was excellent. Echocardiography could only visualize five of 10 conduits in their entirety. Magnetic resonance imaging visualized all conduits and showed statistically significant (kappa = 0.58) agreement with angiography in the localization and estimation of severity of a variety of right-sided obstructions in these patients. However, flow voids created by the metallic ring around xenograft valves led to a false negative diagnosis of valvular stenosis in four patients when magnetic resonance imaging was used alone. Doppler studies correctly indicated obstruction in these patients. The combination of magnetic resonance imaging studies and continuous-wave Doppler echocardiography can be useful to noninvasively evaluate right-sided obstruction in postoperative patients with right-sided extracardiac conduits.

  5. Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging.

    PubMed

    Foerster, Bernd U; Tomasi, Dardo; Caparelli, Elisabeth C

    2005-11-01

    Mechanical vibrations of the gradient coil system during readout in echo-planar imaging (EPI) can increase the temperature of the gradient system and alter the magnetic field distribution during functional magnetic resonance imaging (fMRI). This effect is enhanced by resonant modes of vibrations and results in apparent motion along the phase encoding direction in fMRI studies. The magnetic field drift was quantified during EPI by monitoring the resonance frequency interleaved with the EPI acquisition, and a novel method is proposed to correct the apparent motion. The knowledge on the frequency drift over time was used to correct the phase of the k-space EPI dataset. Since the resonance frequency changes very slowly over time, two measurements of the resonance frequency, immediately before and after the EPI acquisition, are sufficient to remove the field drift effects from fMRI time series. The frequency drift correction method was tested "in vivo" and compared to the standard image realignment method. The proposed method efficiently corrects spurious motion due to magnetic field drifts during fMRI. (c) 2005 Wiley-Liss, Inc.

  6. Diagnostic imaging of posterior fossa anomalies in the fetus.

    PubMed

    Robinson, Ashley James; Ederies, M Ashraf

    2016-10-01

    Ultrasound and magnetic resonance imaging are the two imaging modalities used in the assessment of the fetus. Ultrasound is the primary imaging modality, whereas magnetic resonance is used in cases of diagnostic uncertainty. Both techniques have advantages and disadvantages and therefore they are complementary. Standard axial ultrasound views of the posterior fossa are used for routine scanning for fetal anomalies, with additional orthogonal views directly and indirectly obtainable using three-dimensional ultrasound techniques. Magnetic resonance imaging allows not only direct orthogonal imaging planes, but also tissue characterization, for example to search for blood breakdown products. We review the nomenclature of several posterior fossa anomalies using standardized criteria, and we review cerebellar abnormalities based on an etiologic classification. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. NVR-BIP: Nuclear Vector Replacement using Binary Integer Programming for NMR Structure-Based Assignments.

    PubMed

    Apaydin, Mehmet Serkan; Çatay, Bülent; Patrick, Nicholas; Donald, Bruce R

    2011-05-01

    Nuclear magnetic resonance (NMR) spectroscopy is an important experimental technique that allows one to study protein structure and dynamics in solution. An important bottleneck in NMR protein structure determination is the assignment of NMR peaks to the corresponding nuclei. Structure-based assignment (SBA) aims to solve this problem with the help of a template protein which is homologous to the target and has applications in the study of structure-activity relationship, protein-protein and protein-ligand interactions. We formulate SBA as a linear assignment problem with additional nuclear overhauser effect constraints, which can be solved within nuclear vector replacement's (NVR) framework (Langmead, C., Yan, A., Lilien, R., Wang, L. and Donald, B. (2003) A Polynomial-Time Nuclear Vector Replacement Algorithm for Automated NMR Resonance Assignments. Proc. the 7th Annual Int. Conf. Research in Computational Molecular Biology (RECOMB) , Berlin, Germany, April 10-13, pp. 176-187. ACM Press, New York, NY. J. Comp. Bio. , (2004), 11, pp. 277-298; Langmead, C. and Donald, B. (2004) An expectation/maximization nuclear vector replacement algorithm for automated NMR resonance assignments. J. Biomol. NMR , 29, 111-138). Our approach uses NVR's scoring function and data types and also gives the option of using CH and NH residual dipolar coupling (RDCs), instead of NH RDCs which NVR requires. We test our technique on NVR's data set as well as on four new proteins. Our results are comparable to NVR's assignment accuracy on NVR's test set, but higher on novel proteins. Our approach allows partial assignments. It is also complete and can return the optimum as well as near-optimum assignments. Furthermore, it allows us to analyze the information content of each data type and is easily extendable to accept new forms of input data, such as additional RDCs.

  8. Magnetic resonance imaging of diabetic foot complications

    PubMed Central

    Low, Keynes TA; Peh, Wilfred CG

    2015-01-01

    This pictorial review aims to illustrate the various manifestations of the diabetic foot on magnetic resonance (MR) imaging. The utility of MR imaging and its imaging features in the diagnosis of pedal osteomyelitis are illustrated. There is often difficulty encountered in distinguishing osteomyelitis from neuroarthropathy, both clinically and on imaging. By providing an accurate diagnosis based on imaging, the radiologist plays a significant role in the management of patients with complications of diabetic foot. PMID:25640096

  9. Rectangle Surface Coil Array in a Grid Arrangement for Resonance Imaging

    DTIC Science & Technology

    2016-02-13

    switchable array, RF magnetic field, NQR , MRI, NMR, tuning, decoupling I. INTRODUCTION ESONANCE imaging can be accomplished using Nuclear Magnetic...Resonance (NMR) or Nuclear Quadrupole Resonance ( NQR ) techniques. REF [1] and [6] explain the differences between NMR and NQR . What NMR and NQR ...of resonance NQR frequency of 28.1MHz. The matching and tuning is explain in detail in the next section of this paper. Rectangle Surface Coil

  10. Diagnostic imaging modalities in head and neck disease.

    PubMed

    Dammann, Florian; Bootz, Friedrich; Cohnen, Mathias; Hassfeld, Stefan; Tatagiba, Marcos; Kösling, Sabrina

    2014-06-09

    Because of the complex anatomy of the head and neck region, conventional projection radiography alone is unreliable and carries a high risk of misdiagnosis. The poor risk-benefit ratio of conventional radiography has led to their replacement by tomographic imaging for nearly all studies in this region. This review is based on pertinent articles retrieved by a selective search in the PubMed database (January 1980 to May 2013) as well as on the relevant guidelines from Germany and abroad. The indication for diagnostic imaging in the anatomically complex head and neck region should be established for a specific type of imaging study on the basis of a thorough clinical examination. Conventional films, though easy to obtain, often cannot answer the diagnostic question and may yield confusing information leading to misdiagnosis. Computed tomography (CT) has the best risk-benefit profile and a high diagnostic value, but low-dose protocols have not yet been put into use in all centers. Magnetic resonance imaging (MRI) is best for bone and soft-tissue diagnosis, but consumes more resources. Digital volume tomography (DVT) is another type of three-dimensional, sectional imaging with high local resolution; the associated radiation exposure and image quality are generally both low, but may vary depending on the apparatus used. DVT cannot be used to evaluate the soft tissues. Ultrasonography can be used to evaluate superficial structures in the head and neck region; nuclear imaging can be used to evaluate thyroid disease and cancer. Inflammatory, traumatic, and neoplastic diseases of the head and neck are best evaluated with cross-sectional imaging (CT, MRI) in accordance with current guidelines. Conventional x-rays should, in general, only be used for dental evaluation, with rare exceptions.

  11. Non-resonant zeugmatography with muons (μ SI) and radioactive isotopes

    NASA Astrophysics Data System (ADS)

    Kaplan, N.; Kreitzman, S. R.; Schneider, J. W.; Brewer, J. H.; Hitti, B.

    1994-12-01

    The procedure of zeugmatographic imaging — hitherto implemented only with nuclear magnetic resonance to form the well known MRI technique — is examined with the aim of utilizing it also in combination with non resonant phenomena. It is shown that in principle, one may indeed use zeugmatographic schemes with Perturbed Angular Correlations (PAC) or with muon spin rotations ( μSR) to obtain image information from material bodies. The preliminary experimentation with zeugmatographic μ Spin Imaging scheme, ( μSI), will be described. Some μSI imaging results will be presented and the inherent limitations of the method will be discussed.

  12. Magnetic resonance imaging of amyloid plaques in transgenic mouse models of Alzheimer's disease

    PubMed Central

    Chamberlain, Ryan; Wengenack, Thomas M.; Poduslo, Joseph F.; Garwood, Michael; Jack, Clifford R.

    2011-01-01

    A major objective in the treatment of Alzheimer's disease is amyloid plaque reduction. Transgenic mouse models of Alzheimer's disease provide a controlled and consistent environment for studying amyloid plaque deposition in Alzheimer's disease. Magnetic resonance imaging is an attractive tool for longitudinal studies because it offers non-invasive monitoring of amyloid plaques. Recent studies have demonstrated the ability of magnetic resonance imaging to detect individual plaques in living mice. This review discusses the mouse models, MR pulse sequences, and parameters that have been used to image plaques and how they can be optimized for future studies. PMID:21499442

  13. Measurement of temperature changes in cooling dead rats using magnetic resonance thermometry.

    PubMed

    Kuribayashi, Hideto; Cui, Fanlai; Hirakawa, Keiko; Kanawaku, Yoshimasa; Ohno, Youkichi

    2011-11-01

    Magnetic resonance imaging thermometry has been introduced as a technique for measurement of temperature changes in cooling dead rats. Rat pelvic magnetic resonance images were acquired sequentially more than 2h after euthanasia by halothane overdose. A series of temperature difference maps in cooling dead rats was obtained with calculating imaging phase changes induced by the water proton frequency shift caused by temperature changes. Different cooling processes were monitored by the temperature difference maps in the rats. Magnetic resonance imaging thermometry applied in the study of laboratory animals could theoretically reproduce a variety of causes of death with different environmental conditions. Outcomes from experimental animal studies could be translated into a temperature-based time of death estimation in forensics. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. [Magnetic resonance compatibility research for coronary mental stents].

    PubMed

    Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren

    2015-01-01

    The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.

  15. Opto-mechanical design of vacuum laser resonator for the OSQAR experiment

    NASA Astrophysics Data System (ADS)

    Hošek, Jan; Macúchová, Karolina; Nemcová, Šárka; Kunc, Štěpán.; Šulc, Miroslav

    2015-01-01

    This paper gives short overview of laser-based experiment OSQAR at CERN which is focused on search of axions and axion-like particles. The OSQAR experiment uses two experimental methods for axion search - measurement of the ultra-fine vacuum magnetic birefringence and a method based on the "Light shining through the wall" experiment. Because both experimental methods have reached its attainable limits of sensitivity we have focused on designing a vacuum laser resonator. The resonator will increase the number of convertible photons and their endurance time within the magnetic field. This paper presents an opto-mechanical design of a two component transportable vacuum laser resonator. Developed optical resonator mechanical design allows to be used as a 0.8 meter long prototype laser resonator for laboratory testing and after transportation and replacement of the mirrors it can be mounted on the LHC magnet in CERN to form a 20 meter long vacuum laser resonator.

  16. Investigations on an electroactive polymer based tunable Helmholtz resonator

    NASA Astrophysics Data System (ADS)

    Abbad, A.; Rabenorosoa, K.; Ouisse, M.; Atalla, N.

    2017-04-01

    A Helmholtz resonator is a passive acoustic resonator classically used to control a single frequency resulting from the cavity volume and the resonator neck size. The aim of the proposed study is to present a new concept and strategy allowing real-time tunability of the Helmholtz resonator in order to enhance acoustic absorption performances at low frequencies (< 500 Hz). The proposed concept consists in replacing the resonator rigid front plate by an electroactive polymer (EAP) membrane. The first proposed strategy consists on a change in the mechanical properties of the membrane resulting from the applied electric field. This induces a resonance frequency shift. A second strategy is based on a well-located spring, which could direct the membrane deformation following the axis of the resonator to obtain a cavity volume variation. Both strategies allow variation of the resonance frequency of the device. Experimental measurements are performed to determine the potential of this concept for improvement of low-frequency performances of the acoustic devices.

  17. Contact replacement for NMR resonance assignment.

    PubMed

    Xiong, Fei; Pandurangan, Gopal; Bailey-Kellogg, Chris

    2008-07-01

    Complementing its traditional role in structural studies of proteins, nuclear magnetic resonance (NMR) spectroscopy is playing an increasingly important role in functional studies. NMR dynamics experiments characterize motions involved in target recognition, ligand binding, etc., while NMR chemical shift perturbation experiments identify and localize protein-protein and protein-ligand interactions. The key bottleneck in these studies is to determine the backbone resonance assignment, which allows spectral peaks to be mapped to specific atoms. This article develops a novel approach to address that bottleneck, exploiting an available X-ray structure or homology model to assign the entire backbone from a set of relatively fast and cheap NMR experiments. We formulate contact replacement for resonance assignment as the problem of computing correspondences between a contact graph representing the structure and an NMR graph representing the data; the NMR graph is a significantly corrupted, ambiguous version of the contact graph. We first show that by combining connectivity and amino acid type information, and exploiting the random structure of the noise, one can provably determine unique correspondences in polynomial time with high probability, even in the presence of significant noise (a constant number of noisy edges per vertex). We then detail an efficient randomized algorithm and show that, over a variety of experimental and synthetic datasets, it is robust to typical levels of structural variation (1-2 AA), noise (250-600%) and missings (10-40%). Our algorithm achieves very good overall assignment accuracy, above 80% in alpha-helices, 70% in beta-sheets and 60% in loop regions. Our contact replacement algorithm is implemented in platform-independent Python code. The software can be freely obtained for academic use by request from the authors.

  18. Improved tolerance to off-resonance in spectral-spatial EPI of hyperpolarized [1-13 C]pyruvate and metabolites.

    PubMed

    Lau, Justin Y C; Geraghty, Benjamin J; Chen, Albert P; Cunningham, Charles H

    2018-09-01

    For 13 C echo-planar imaging (EPI) with spectral-spatial excitation, main field inhomogeneity can result in reduced flip angle and spatial artifacts. A hybrid time-resolved pulse sequence, multi-echo spectral-spatial EPI, is proposed combining broader spectral-spatial passbands for greater off-resonance tolerance with a multi-echo acquisition to separate signals from potentially co-excited resonances. The performance of the imaging sequence and the reconstruction pipeline were evaluated for 1 H imaging using a series of increasingly dilute 1,4-dioxane solutions and for 13 C imaging using an ethylene glycol phantom. Hyperpolarized [1- 13 C]pyruvate was administered to two healthy rats. Multi-echo data of the rat kidneys were acquired to test realistic cases of off-resonance. Analysis of separated images of water and 1,4-dioxane following multi-echo signal decomposition showed water-to-dioxane 1 H signal ratios that were in agreement with the independent measurements by 1 H spectroscopy for all four concentrations of 1,4-dioxane. The 13 C signal ratio of two co-excited resonances of ethylene glycol was accurately recovered after correction for the spectral profile of the redesigned spectral-spatial pulse. In vivo, successful separation of lactate and pyruvate-hydrate signals was achieved for all except the early time points during which signal variations exceeded the temporal resolution of the multi-echo acquisition. Improved tolerance to off-resonance in the new 13 C data acquisition pipeline was demonstrated in vitro and in vivo. Magn Reson Med 80:925-934, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  19. Clinical Features, Diagnosis, and Management of Patients With Anderson-Fabry Cardiomyopathy.

    PubMed

    Yogasundaram, Haran; Kim, Daniel; Oudit, Omar; Thompson, Richard B; Weidemann, Frank; Oudit, Gavin Y

    2017-07-01

    Anderson-Fabry disease (AFD) is an X-linked recessive, multisystem disease of lysosomal storage. A mutation in the gene encoding the hydrolase enzyme α-galactosidase A results in its deficiency, or complete absence of activity. Subsequent progressive intracellular accumulation of glycosphingolipids, predominantly globotriaosylceramide, in various tissues, results in progressive organ dysfunction and failure, most commonly affecting the kidneys, nervous system, skin, eyes, vascular endothelium, and the heart. Cardiac involvement in AFD represents a leading cause of morbidity and mortality. Globotriaosylceramide accumulation affects cardiomyocytes, smooth muscle cells, vascular endothelial cells, and fibroblasts leading to various pathologies including valvular regurgitation, conduction disease and arrhythmias, coronary microvascular dysfunction, and right and left ventricular hypertrophy (LVH) leading to early diastolic dysfunction and late-stage systolic impairment. Diagnosis is on the basis of decreased plasma α-galactosidase activity in men and positive genetic testing in women. Contemporary large-scale screening studies have revealed a prevalence of 1%-5% in patients with unexplained LVH in multiple cohorts. Cardiac magnetic resonance imaging, with its unique tissue characterization capabilities, is the most important imaging modality to assess for cardiomyopathy in patients with AFD. Enzyme replacement therapy is indicated in AFD patients with significant organ involvement, and has been shown to clear sphingolipids from endothelial cells in other organs, as well as to reduce left ventricular mass as early as 6 months after starting treatment. There is increasing evidence that enzyme replacement therapy might be more effective if given at earlier stages of disease, before the development of LVH and myocardial fibrosis. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  20. All you need to know about the tricuspid valve: Tricuspid valve imaging and tricuspid regurgitation analysis.

    PubMed

    Huttin, Olivier; Voilliot, Damien; Mandry, Damien; Venner, Clément; Juillière, Yves; Selton-Suty, Christine

    2016-01-01

    The acknowledgment of tricuspid regurgitation (TR) as a stand-alone and progressive entity, worsening the prognosis of patients whatever its aetiology, has led to renewed interest in the tricuspid-right ventricular complex. The tricuspid valve (TV) is a complex, dynamic and changing structure. As the TV is not easy to analyse, three-dimensional imaging, cardiac magnetic resonance imaging and computed tomography scans may add to two-dimensional transthoracic and transoesophageal echocardiographic data in the analysis of TR. Not only the severity of TR, but also its mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. TR is functional and is a satellite of left-sided heart disease and/or elevated pulmonary artery pressure most of the time; a particular form is characterized by TR worsening after left-sided valve surgery, which has been shown to impair patient prognosis. A better description of TV anatomy and function by multimodality imaging should help with the appropriate selection of patients who will benefit from either surgical TV repair/replacement or a percutaneous procedure for TR, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. New Subarray Readout Patterns for the ACS Wide Field Channel

    NASA Astrophysics Data System (ADS)

    Golimowski, D.; Anderson, J.; Arslanian, S.; Chiaberge, M.; Grogin, N.; Lim, Pey Lian; Lupie, O.; McMaster, M.; Reinhart, M.; Schiffer, F.; Serrano, B.; Van Marshall, M.; Welty, A.

    2017-04-01

    At the start of Cycle 24, the original CCD-readout timing patterns used to generate ACS Wide Field Channel (WFC) subarray images were replaced with new patterns adapted from the four-quadrant readout pattern used to generate full-frame WFC images. The primary motivation for this replacement was a substantial reduction of observatory and staff resources needed to support WFC subarray bias calibration, which became a new and challenging obligation after the installation of the ACS CCD Electronics Box Replacement during Servicing Mission 4. The new readout patterns also improve the overall efficiency of observing with WFC subarrays and enable the processing of subarray images through stages of the ACS data calibration pipeline (calacs) that were previously restricted to full-frame WFC images. The new readout patterns replace the original 512×512, 1024×1024, and 2048×2046-pixel subarrays with subarrays having 2048 columns and 512, 1024, and 2048 rows, respectively. Whereas the original square subarrays were limited to certain WFC quadrants, the new rectangular subarrays are available in all four quadrants. The underlying bias structure of the new subarrays now conforms with those of the corresponding regions of the full-frame image, which allows raw frames in all image formats to be calibrated using one contemporaneous full-frame "superbias" reference image. The original subarrays remain available for scientific use, but calibration of these image formats is no longer supported by STScI.

  2. Chlorophyll-a analogues conjugated with aminobenzyl-DTPA as potential bifunctional agents for magnetic resonance imaging and photodynamic therapy.

    PubMed

    Li, Guolin; Slansky, Adam; Dobhal, Mahabeer P; Goswami, Lalit N; Graham, Andrew; Chen, Yihui; Kanter, Peter; Alberico, Ronald A; Spernyak, Joseph; Morgan, Janet; Mazurchuk, Richard; Oseroff, Allan; Grossman, Zachary; Pandey, Ravindra K

    2005-01-01

    A clinically relevant photosensitizer, 3-devinyl-3-(1-hexyloxyethyl)pyropheophorbide-a (HPPH, a chlorophyll-a derivative), was conjugated with Gd(III)-aminobenzyl-diethylenetriaminepentaacetic acid (DTPA), an experimental magnetic resonance (MR) imaging agent. In vivo reflectance spectroscopy confirmed tumor uptake of HPPH-aminobenzyl-Gd(III)-DTPA conjugate was higher than free HPPH administered intraveneously (iv) to C3H mice with subcutaneously (sc) implanted radiation-induced fibrosarcoma (RIF) tumor cells. In other experiments, Sprague-Dawley (SD) rats with sc implanted Ward Colon Carcinoma cells yielded markedly increased MR signal intensities from tumor regions-of-interest (ROIs) 24 h post-iv injection of HPPH-aminobenzyl-Gd(III)-DTPA conjugate as compared to unconjugated HPPH. In both in vitro (RIF tumor cells) and in vivo (mice bearing RIF tumors and rats bearing Ward Colon tumors) the conjugate produced significant increases in tumor conspicuity at 1.5 T and retained therapeutic efficacy following PDT. Also synthesized were a series of novel bifunctional agents containing two Gd(III) atoms per HPPH molecule that remained tumor-avid and PDT-active and yielded improved MR tumor conspicuity compared to their corresponding mono-Gd(III) analogues. Administered iv at a MR imaging dose of 10 micromol/kg, these conjugates produced severe skin phototoxicity. However, by replacing the hexyl group of the pyropheophorbide-a with a tri(ethylene glycol) monomethyl ether (PEG-methyl ether), these conjugates produced remarkable MR tumor enhancement at 8 h post-iv injection, significant tumoricidal activity (80% of mice were tumor-free on day 90), and reduced skin phototoxicity compared to their corresponding hexyl ether analogues. The poor water-solubility characteristic of these conjugates was resolved by incorporation into a liposomal formulation. This paper presents the synthesis of tumor-avid contrast enhancing agents for MR imaging and thus represents an important milestone toward improving cancer diagnosis and tumor characterization. More importantly, this paper describes a new family of bifunctional agents that combine two modalities into a single cost-effective "see and treat" approach, namely, a single agent that can be used for contrast agent-enhanced MR imaging followed by targeted photodynamic therapy.

  3. Interferometric detection of nanoparticles

    NASA Astrophysics Data System (ADS)

    Hayrapetyan, Karen

    Interferometric surfaces enhance light scattering from nanoparticles through constructive interference of partial scattered waves. By placing the nanoparticles on interferometric surfaces tuned to a special surface phase interferometric condition, the particles are detectable in the dilute limit through interferometric image contrast in a heterodyne light scattering configuration, or through diffraction in a homodyne scattering configuration. The interferometric enhancement has applications for imaging and diffractive biosensors. We present a modified model based on Double Interaction (DI) to explore bead-based detection mechanisms using imaging, scanning and diffraction. The application goal of this work is to explore the trade-offs between the sensitivity and throughput among various detection methods. Experimentally we use thermal oxide on silicon to establish and control surface interferometric conditions. Surface-captured gold beads are detected using Molecular Interferometric Imaging (MI2) and Spinning-Disc Interferometry (SDI). Double-resonant enhancement of light scattering leads to high-contrast detection of 100 nm radius gold nanoparticles on an interferometric surface. The double-resonance condition is achieved when resonance (or anti-resonance) from an asymmetric Fabry-Perot substrate coincides with the Mie resonance of the gold nanoparticle. The double-resonance condition is observed experimentally using molecular interferometric imaging (MI2). An invisibility condition is identified for which the gold nanoparticles are optically cloaked by the interferometric surface.

  4. MRI and the distribution of bone marrow fat in hip osteoarthritis.

    PubMed

    Gregory, Jennifer S; Barr, Rebecca J; Varela, Victor; Ahearn, Trevor S; Gardiner, Jennifer Lee; Gilbert, Fiona J; Redpath, Thomas W; Hutchison, James D; Aspden, Richard M

    2017-01-01

    To characterize the distribution of bone marrow fat in hip osteoarthritis (OA) using magnetic resonance imaging (MRI) and to assess its use as a potential biomarker. In all, 67 subjects (39 female, 28 male) with either total hip replacement (THA) or different severities of radiographic OA, assessed by Kellgren-Lawrence grading (KLG), underwent 3T MRI of the pelvis using the IDEAL sequence to separate fat and water signals. Six regions of interest (ROIs) were identified within the proximal femur. Within each ROI the fractional-fat distribution, represented by pixel intensities, was described by its mean, standard deviation, skewness, kurtosis, and entropy. Hips were graded: 12 as severe symptomatic (THA), 33 had KLG0 or 1, 9 were KLG2, 11 with KLG3, and 2 with KLG4 were analyzed together. The fractional-fat content in the whole proximal femur did not vary with severity in males (mean (SD) 91.2 (6.0)%) but reduced with severity in females from 89.1 (6.7)% (KLG0,1), 91.5 (2.9)% (KLG2), 85.8 (16.7)% (KLG3,4) to 77.5 (11.9)% (THA) (analysis of variance [ANOVA] P = 0.029). These differences were most pronounced in the femoral head, where mean values fell with OA severity in both sexes from 97.9% (2.5%) (KLG0,1) to 73.0% (25.9%) (THA, P < 0.001) with the largest difference at the final stage. The standard deviation and the entropy of the distribution both increased (P < 0.001). Descriptors of the fractional fat distribution varied little with the severity of OA until the most severe stage, when changes appeared mainly in the femoral head, and have, therefore, limited value as biomarkers. 2 J. Magn. Reson. Imaging 2017;45:42-50. © 2016 International Society for Magnetic Resonance in Medicine.

  5. Feasibility and Diagnostic Value of Cardiovascular Magnetic Resonance Imaging After Acute Ischemic Stroke of Undetermined Origin.

    PubMed

    Haeusler, Karl Georg; Wollboldt, Christian; Bentheim, Laura Zu; Herm, Juliane; Jäger, Sebastian; Kunze, Claudia; Eberle, Holger-Carsten; Deluigi, Claudia Christina; Bruder, Oliver; Malsch, Carolin; Heuschmann, Peter U; Endres, Matthias; Audebert, Heinrich J; Morguet, Andreas J; Jensen, Christoph; Fiebach, Jochen B

    2017-05-01

    Etiology of acute ischemic stroke remains undetermined (cryptogenic) in about 25% of patients after state-of-the-art diagnostic work-up. One-hundred and three patients with magnetic resonance imaging (MRI)-proven acute ischemic stroke of undetermined origin were prospectively enrolled and underwent 3-T cardiac MRI and magnetic resonance angiography of the aortic arch in addition to state-of-the-art diagnostic work-up, including transesophageal echocardiography (TEE). We analyzed the feasibility, diagnostic accuracy, and added value of cardiovascular MRI (cvMRI) compared with TEE for detecting sources of stroke. Overall, 102 (99.0%) ischemic stroke patients (median 63 years [interquartile range, 53-72], 24% female, median NIHSS (National Institutes of Health Stroke Scale) score on admission 2 [interquartile range, 1-4]) underwent cvMRI and TEE in hospital; 89 (86.4%) patients completed the cvMRI examination. In 93 cryptogenic stroke patients, a high-risk embolic source was found in 9 (8.7%) patients by cvMRI and in 11 (11.8%) patients by echocardiography, respectively. cvMRI and echocardiography findings were consistent in 80 (86.0%) patients, resulting in a degree of agreement of κ=0.24. In 82 patients with cryptogenic stroke according to routine work-up, including TEE, cvMRI identified stroke etiology in additional 5 (6.1%) patients. Late gadolinium enhancement consistent with previous myocardial infarction was found in 13 (14.6%) out of 89 stroke patients completing cvMRI. Only 2 of these 13 patients had known coronary artery disease. Our study demonstrated that cvMRI was feasible in the vast majority of included patients with acute ischemic stroke. The diagnostic information of cvMRI seems to be complementary to TEE but is not replacing echocardiography after acute ischemic stroke. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01917955. © 2017 American Heart Association, Inc.

  6. Deep ultraviolet resonant Raman imaging of a cell

    NASA Astrophysics Data System (ADS)

    Kumamoto, Yasuaki; Taguchi, Atsushi; Smith, Nicholas Isaac; Kawata, Satoshi

    2012-07-01

    We report the first demonstration of deep ultraviolet (DUV) Raman imaging of a cell. Nucleotide distributions in a HeLa cell were observed without any labeling at 257 nm excitation with resonant bands attributable to guanine and adenine. Obtained images represent DNA localization at nucleoli in the nucleus and RNA distribution in the cytoplasm. The presented technique extends the potential of Raman microscopy as a tool to selectively probe nucleic acids in a cell with high sensitivity due to resonance.

  7. Magnetic resonance imaging diagnosis of disseminated necrotizing leukoencephalopathy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atlas, S.W.; Grossman, R.I.; Packer, R.J.

    1987-01-01

    Disseminated necrotizing leukoencephalopathy is a rare syndrome of progressive neurologic deterioration seen most often in patients who have received central nervous system irradiation combined with intrathecal or systemic chemotherapy in the treatment or prophylaxis of various malignancies. Magnetic resonance imaging was more sensitive than computed tomography in detecting white matter abnormalities in the case of disseminated necrotizing leukoencephalopathy reported here. Magnetic resonance imaging may be useful in diagnosing incipient white matter changes in disseminated necrotizing leukoencephalopathy, thus permitting early, appropriate therapeutic modifications.

  8. Granular convection observed by magnetic resonance imaging.

    PubMed

    Ehrichs, E E; Jaeger, H M; Karczmar, G S; Knight, J B; Kuperman, V Y; Nagel, S R

    1995-03-17

    Vibrations in a granular material can spontaneously produce convection rolls reminiscent of those seen in fluids. Magnetic resonance imaging provides a sensitive and noninvasive probe for the detection of these convection currents, which have otherwise been difficult to observe. A magnetic resonance imaging study of convection in a column of poppy seeds yielded data about the detailed shape of the convection rolls and the depth dependence of the convection velocity. The velocity was found to decrease exponentially with depth; a simple model for this behavior is presented here.

  9. Traumatic Brain Injury Diffusion Magnetic Resonance Imaging Research Roadmap Development Project

    DTIC Science & Technology

    2011-10-01

    promising technology on the horizon is the Diffusion Tensor Imaging ( DTI ). Diffusion tensor imaging ( DTI ) is a magnetic resonance imaging (MRI)-based...in the brain. The potential for DTI to improve our understanding of TBI has not been fully explored and challenges associated with non-existent...processing tools, quality control standards, and a shared image repository. The recommendations will be disseminated and pilot tested. A DTI of TBI

  10. A dual RF resonator system for high-field functional magnetic resonance imaging of small animals.

    PubMed

    Ludwig, R; Bodgdanov, G; King, J; Allard, A; Ferris, C F

    2004-01-30

    A new apparatus has been developed that integrates an animal restrainer arrangement for small animals with an actively tunable/detunable dual radio-frequency (RF) coil system for in vivo anatomical and functional magnetic resonance imaging of small animals at 4.7 T. The radio-frequency coil features an eight-element microstrip line configuration that, in conjunction with a segmented outer copper shield, forms a transversal electromagnetic (TEM) resonator structure. Matching and active tuning/detuning is achieved through fixed/variable capacitors and a PIN diode for each resonator element. These components along with radio-frequency chokes (RFCs) and blocking capacitors are placed on two printed circuit boards (PCBs) whose copper coated ground planes form the front and back of the volume coil and are therefore an integral part of the resonator structure. The magnetic resonance signal response is received with a dome-shaped single-loop surface coil that can be height-adjustable with respect to the animal's head. The conscious animal is immobilized through a mechanical arrangement that consists of a Plexiglas body tube and a head restrainer. This restrainer has a cylindrical holder with a mouthpiece and position screws to receive and restrain the head of the animal. The apparatus is intended to perform anatomical and functional magnetic resonance imaging in conscious animals such as mice, rats, hamsters, and marmosets. Cranial images acquired from fully conscious rats in a 4.7 T Bruker 40 cm bore animal scanner underscore the feasibility of this approach and bode well to extend this system to the imaging of other animals.

  11. The new generation polestar n20 for conventional neurosurgical operating rooms: a preliminary report.

    PubMed

    Ntoukas, Vasileios; Krishnan, Rene; Seifert, Volker

    2008-03-01

    The objective of this work is to present the preliminary clinical experience we acquired in using the new PoleStar generation, N20 (Medtronic Navigation, Louisville, CO), in a modified conventional operating room. PoleStar N20 is a 0.15-T, intraoperative scanner combined with both an integrated optical and a magnetic resonance imaging tracking scanner. All standard imaging modes, such as T1, T2, and fluid-attenuated inversion recovery, are available through the magnet. To shield the operating room from radiofrequency interference, a Faraday cage was constructed using a conductive metal mesh installed under the wall decoration. Sixty-one patients, most of whom had gliomas or pituitary adenomas, underwent intraoperative magnetic resonance imaging in our clinic. The extent of resection and the surgical consequences of intraoperative imaging were analyzed. The image quality for T1-weighted, gadolinium-enhanced tumors was sufficiently good to enable us to evaluate the extent of tumor resection, whereas the T2-weighted image quality must be improved. New technologies, such as high-temperature superconductive coils and ultra-small super-paramagnetic iron particles, e.g., ferumoxtran-10, can lead to a dramatic improvement in image quality, heralding the commencement of the widespread use of intraoperative magnetic resonance imaging. The acquisition of the PoleStar N20 opened new horizons in the treatment of our patients. This novel, compact, intraoperative magnetic resonance imaging scanner can be installed in a standard operating room without major modifications. Standard surgical instruments can be used. Intraoperative magnetic resonance imaging provided valuable information that allowed intraoperative modification of the surgical strategy.

  12. Magnetic resonance imaging-ultrasound fusion biopsy for prediction of final prostate pathology.

    PubMed

    Le, Jesse D; Stephenson, Samuel; Brugger, Michelle; Lu, David Y; Lieu, Patricia; Sonn, Geoffrey A; Natarajan, Shyam; Dorey, Frederick J; Huang, Jiaoti; Margolis, Daniel J A; Reiter, Robert E; Marks, Leonard S

    2014-11-01

    We explored the impact of magnetic resonance imaging-ultrasound fusion prostate biopsy on the prediction of final surgical pathology. A total of 54 consecutive men undergoing radical prostatectomy at UCLA after fusion biopsy were included in this prospective, institutional review board approved pilot study. Using magnetic resonance imaging-ultrasound fusion, tissue was obtained from a 12-point systematic grid (mapping biopsy) and from regions of interest detected by multiparametric magnetic resonance imaging (targeted biopsy). A single radiologist read all magnetic resonance imaging, and a single pathologist independently rereviewed all biopsy and whole mount pathology, blinded to prior interpretation and matched specimen. Gleason score concordance between biopsy and prostatectomy was the primary end point. Mean patient age was 62 years and median prostate specific antigen was 6.2 ng/ml. Final Gleason score at prostatectomy was 6 (13%), 7 (70%) and 8-9 (17%). A tertiary pattern was detected in 17 (31%) men. Of 45 high suspicion (image grade 4-5) magnetic resonance imaging targets 32 (71%) contained prostate cancer. The per core cancer detection rate was 20% by systematic mapping biopsy and 42% by targeted biopsy. The highest Gleason pattern at prostatectomy was detected by systematic mapping biopsy in 54%, targeted biopsy in 54% and a combination in 81% of cases. Overall 17% of cases were upgraded from fusion biopsy to final pathology and 1 (2%) was downgraded. The combination of targeted biopsy and systematic mapping biopsy was needed to obtain the best predictive accuracy. In this pilot study magnetic resonance imaging-ultrasound fusion biopsy allowed for the prediction of final prostate pathology with greater accuracy than that reported previously using conventional methods (81% vs 40% to 65%). If confirmed, these results will have important clinical implications. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. MRI Safety during Pregnancy

    MedlinePlus

    ... during the exam? Contrast material MRI during pregnancy Magnetic resonance imaging (MRI) If you are pregnant and your doctor wants to perform a magnetic resonance imaging (MRI) exam, there is a possibility that your ...

  14. Magnetic resonance imaging of spinal infection.

    PubMed

    Tins, Bernhard J; Cassar-Pullicino, Victor N; Lalam, Radhesh K

    2007-06-01

    This article reviews the pathophysiology of spinal infection and its relevance for imaging. Magnetic resonance imaging (MRI) is the modality with by far the best sensitivity and specificity for spinal infection. The imaging appearances of spinal infection in MRI are outlined, and imaging techniques are discussed. The problems of clinical diagnosis are outlined. There is some emphasis on the MRI differentiation of pyogenic and nonpyogenic infection and on the differential diagnosis of spinal infection centered on the imaging presentation.

  15. Ability of preoperative 3.0-Tesla magnetic resonance imaging to predict the absence of side-specific extracapsular extension of prostate cancer.

    PubMed

    Hara, Tomohiko; Nakanishi, Hiroyuki; Nakagawa, Tohru; Komiyama, Motokiyo; Kawahara, Takashi; Manabe, Tomoko; Miyake, Mototaka; Arai, Eri; Kanai, Yae; Fujimoto, Hiroyuki

    2013-10-01

    Recent studies have shown an improvement in prostate cancer diagnosis with the use of 3.0-Tesla magnetic resonance imaging. We retrospectively assessed the ability of this imaging technique to predict side-specific extracapsular extension of prostate cancer. From October 2007 to August 2011, prostatectomy was carried out in 396 patients after preoperative 3.0-Tesla magnetic resonance imaging. Among these, 132 (primary sample) and 134 patients (validation sample) underwent 12-core prostate biopsy at the National Cancer Center Hospital of Tokyo, Japan, and at other institutions, respectively. In the primary dataset, univariate and multivariate analyses were carried out to predict side-specific extracapsular extension using variables determined preoperatively, including 3.0-Tesla magnetic resonance imaging findings (T2-weighted and diffusion-weighted imaging). A prediction model was then constructed and applied to the validation study sample. Multivariate analysis identified four significant independent predictors (P < 0.05), including a biopsy Gleason score of ≥8, positive 3.0-Tesla diffusion-weighted magnetic resonance imaging findings, ≥2 positive biopsy cores on each side and a maximum percentage of positive cores ≥31% on each side. The negative predictive value was 93.9% in the combination model with these four predictors, meanwhile the positive predictive value was 33.8%. Good reproducibility of these four significant predictors and the combination model was observed in the validation study sample. The side-specific extracapsular extension prediction by the biopsy Gleason score and factors associated with tumor location, including a positive 3.0-Tesla diffusion-weighted magnetic resonance imaging finding, have a high negative predictive value, but a low positive predictive value. © 2013 The Japanese Urological Association.

  16. Detection of cerebral amyloid angiopathy by 3-T magnetic resonance imaging and amyloid positron emission tomography in a patient with subcortical ischaemic vascular dementia.

    PubMed

    Kida, Hirotaka; Satoh, Masayuki; Ii, Yuichiro; Fukuyama, Hidenao; Maeda, Masayuki; Tomimoto, Hidekazu

    2017-01-01

    The patient was an 81-year-old man who had been treated for hypertension for several decades. In 2012, he developed gait disturbance and mild amnesia. One year later, his gait disturbance worsened, and he developed urinary incontinence. Conventional brain magnetic resonance imaging using T 2 -weighted images and fluid-attenuated inversion recovery showed multiple lacunar infarctions. These findings fulfilled the diagnostic criteria for subcortical ischaemic vascular dementia. However, susceptibility weighted imaging showed multiple lobar microbleeds in the bilateral occipitoparietal lobes, and double inversion recovery and 3-D fluid-attenuated inversion recovery images on 3-T magnetic resonance imaging revealed cortical microinfarctions in the left parietal-temporo-occipito region. Pittsburgh compound B-positron emission tomography revealed diffuse uptake in the cerebral cortex. Therefore, we diagnosed the patient with subcortical ischaemic vascular dementia associated with Alzheimer's disease. The use of the double inversion recovery and susceptibility weighted imaging on 3-T magnetic resonance imaging may be a supplemental strategy for diagnosing cerebral amyloid angiopathy, which is closely associated with Alzheimer's disease. © 2016 The Authors. Psychogeriatrics © 2016 Japanese Psychogeriatric Society.

  17. Magnetic resonance imaging of glenohumeral joint instability.

    PubMed

    Steinbach, Lynne S

    2005-03-01

    Shoulder instability is common, especially anterior subluxation and dislocation. The sequelae are well seen on magnetic resonance imaging and include tears of the labrum, glenohumeral ligaments, capsule, tendons, and muscles. This article seeks to discuss and illustrate common pitfalls and lesions associated with instability. Anatomic and technical considerations, including the use of magnetic resonance arthrography, are also addressed.

  18. Parathyroid adenoma associated with neurofibromatosis: Correlative scintigraphic and magnetic resonance imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vogelzang, P.J.; Oates, E.; Bankoff, M.S.

    Correlative imaging by dual-isotope thallium/technetium subtraction scintigraphy, computed tomography, and magnetic resonance imaging demonstrated a pathologically proven parathyroid adenoma in a 62-year-old man with known neurofibromatosis, who presented with hypercalcemia and an elevated parathormone level. The association between neurofibromatosis and primary hyperparathyroidism is discussed.

  19. [From anatomy to image: the cranial nerves at MRI].

    PubMed

    Conforti, Renata; Marrone, Valeria; Sardaro, Angela; Faella, Pierluigi; Grassi, Roberta; Cappabianca, Salvatore

    2013-01-01

    In this article, we review the expected course of each of the 12 cranial nerves. Traditional magnetic resonance imaging depicts only the larger cranial nerves but SSFP sequences of magnetic resonance imaging are capable of depicting the cisternal segments of 12 cranial nerves and also provide submillimetric spatial resolution.

  20. Early-Onset Central Diabetes Insipidus due to Compound Heterozygosity for AVP Mutations.

    PubMed

    Bourdet, Karine; Vallette, Sophie; Deladoëy, Johnny; Van Vliet, Guy

    2016-01-01

    Genetic cases of isolated central diabetes insipidus are rare, are mostly due to dominant AVP mutations and have a delayed onset of symptoms. Only 3 consanguineous pedigrees with a recessive form have been published. A boy with a negative family history presented polyuria and failure to thrive in the first months of life and was diagnosed with central diabetes insipidus. Magnetic resonance imaging showed a normal posterior pituitary signal. A molecular genetic analysis of the AVP gene showed that he had inherited a previously reported mutation from his Lebanese father and a novel A>G transition in the splice acceptor site of intron 1 (IVS1-2A>G) from his French-Canadian mother. Replacement therapy resulted in the immediate disappearance of symptoms and in weight gain. The early polyuria in recessive central diabetes insipidus contrasts with the delayed presentation in patients with monoallelic AVP mutations. This diagnosis needs to be considered in infants with very early onset of polyuria-polydipsia and no brain malformation, even if there is no consanguinity and regardless of whether the posterior pituitary is visible or not on imaging. In addition to informing family counseling, making a molecular diagnosis eliminates the need for repeated imaging studies. © 2015 S. Karger AG, Basel.

  1. Rationale and design of the SMaRT trial: A randomised, prospective, parallel, non-blinded, one-centre trial to evaluate the use of magnetic resonance imaging in acute setting in patients presenting with suspected scaphoid fracture.

    PubMed

    Rua, Tiago; Vijayanathan, Sanjay; Parkin, David; Goh, Vicky; McCrone, Paul; Gidwani, Sam

    2018-04-01

    Background Wrist injury is a common presentation to the Emergency Department in the United Kingdom. Among these injuries, the scaphoid is the most common fractured carpal bone. However, given the limited ability of conventional radiography to accurately diagnose a suspected scaphoid fracture on presentation, its diagnosis and management remain challenging. Despite the vast clinical evidence supporting the superior accuracy of magnetic resonance imaging, there is little to no evidence around the real-world clinical and economic impact of immediate magnetic resonance imaging in the management of suspected scaphoid fractures. Methods Review of design and implementation challenges associated with the identification and subsequent recruitment of eligible patients, implementation of a novel clinical pathway in an acute setting, rationale behind the primary and secondary outcomes selected and measurement of the primary outcome. Results The Scaphoid Magnetic Resonance Imaging in Trauma trial is a single-site prospective, randomised, non-blinded, parallel design trial that aims to evaluate the use of immediate magnetic resonance imaging in the management of patients presenting to the acute setting with suspected scaphoid fractures. The primary outcome is the total 3-month cost per patient associated with the diagnosis and treatment of suspected scaphoid fractures. It is hypothesised that the immediate use of magnetic resonance imaging, a more accurate but expensive imaging modality, in patients with negative findings in the initial four-view radiography, will reduce the overall National Health Service costs by promoting definitive care and avoiding unnecessary diagnostic and treatment procedures. Other rationale design considerations in the recruitment, randomisation, data acquisition and intervention implementation are also discussed. Several of these challenges derive from real-world operational issues associated with the provision of magnetic resonance imaging in an intrinsically complex acute setting. Staff engagement during the trial's planning phase, combined with an extensive training programme rolled out prior to the trial's launch, were essential to raise staff awareness and engagement. Given the acute nature of the clinical condition, the latter was deemed essential as the eligibility assessment, recruitment, randomisation and treatment allocation processes all need to happen in a very tight time frame. Limitations Findings from the Scaphoid Magnetic Resonance Imaging in Trauma trial might not be generalisable to other National Health Service hospitals, foreign healthcare systems nor patient presentations outside normal magnetic resonance imaging working hours. Conclusion The Scaphoid Magnetic Resonance Imaging in Trauma trial was designed to evaluate the costs, patient satisfaction and clinical outcomes around the management of suspected scaphoid fractures and ultimately provide solid evidence on which to base the United Kingdom and international clinical practice. This article discusses the steps considered in the design of this novel trial, with particular emphasis on the issues and lessons learned during the planning and implementation stages.

  2. Prostate Specific Membrane Antigen Positron Emission Tomography May Improve the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging in Localized Prostate Cancer.

    PubMed

    Rhee, H; Thomas, P; Shepherd, B; Gustafson, S; Vela, I; Russell, P J; Nelson, C; Chung, E; Wood, G; Malone, G; Wood, S; Heathcote, P

    2016-10-01

    Positron emission tomography using ligands targeting prostate specific membrane antigen has recently been introduced. Positron emission tomography imaging with (68)Ga-PSMA-HBED-CC has been shown to detect metastatic prostate cancer lesions at a high rate. In this study we compare multiparametric magnetic resonance imaging and prostate specific membrane antigen positron emission tomography of the prostate with whole mount ex vivo prostate histopathology to determine the true sensitivity and specificity of these imaging modalities for detecting and locating tumor foci within the prostate. In a prospective clinical trial setting 20 patients with localized prostate cancer and a planned radical prostatectomy were recruited. All patients underwent multiparametric magnetic resonance imaging and positron emission tomography before surgery, and whole mount histopathology slides were directly compared to the images. European Society of Urogenital Radiology guidelines for reporting magnetic resonance imaging were used as a template for regional units of analysis. The uropathologist and radiologists were blinded to individual components of the study, and the final correlation was performed by visual and deformable registration analysis. A total of 50 clinically significant lesions were identified from the whole mount histopathological analysis. Based on regional analysis the sensitivity, specificity, positive predictive value and negative predictive value for multiparametric magnetic resonance imaging were 44%, 94%, 81% and 76%, respectively. With prostate specific membrane antigen positron emission tomography the sensitivity, specificity, positive predictive value and negative predictive value were 49%, 95%, 85% and 88%, respectively. Prostate specific membrane antigen positron emission tomography yielded a higher specificity and positive predictive value. A significant proportion of cancers are potentially missed and underestimated by both imaging modalities. Prostate specific membrane antigen positron emission tomography may be used in addition to multiparametric magnetic resonance imaging to help improve local staging in those patients undergoing retropubic radical prostatectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Spondyloarthropathy: diagnostic imaging criteria for the detection of sacroiliitis

    PubMed Central

    de Castro Jr., Moacir Ribeiro; Mitraud, Sonia de Aguiar Vilela; Francisco, Marina Celli; Fernandes, Artur da Rocha Corrêa; Fernandes, Eloy de Ávila

    2017-01-01

    Diagnostic imaging is crucial to the diagnosis and monitoring of spondyloarthropathies. Magnetic resonance imaging is the most relevant tool for the early detection of sacroiliitis, allowing the institution of therapeutic strategies to impede the progression of the disease. This study illustrates the major criteria for a magnetic resonance imaging-based diagnosis of spondyloarthropathy. The cases selected here present images obtained from the medical records of patients diagnosed with sacroiliitis over a two-year period at our facility, depicting the active and chronic, irreversible forms of the disease. Although computed tomography and conventional radiography can also identify structural changes, such as subchondral sclerosis, erosions, fat deposits, and ankylosis, only magnetic resonance imaging can reveal active inflammatory lesions, such as bone edema, osteitis, synovitis, enthesitis, and capsulitis. PMID:28894334

  4. Magnetic resonance-transcranial ultrasound fusion imaging: A novel tool for brain electrode location.

    PubMed

    Walter, Uwe; Müller, Jan-Uwe; Rösche, Johannes; Kirsch, Michael; Grossmann, Annette; Benecke, Reiner; Wittstock, Matthias; Wolters, Alexander

    2016-03-01

    A combination of preoperative magnetic resonance imaging (MRI) with real-time transcranial ultrasound, known as fusion imaging, may improve postoperative control of deep brain stimulation (DBS) electrode location. Fusion imaging, however, employs a weak magnetic field for tracking the position of the ultrasound transducer and the patient's head. Here we assessed its feasibility, safety, and clinical relevance in patients with DBS. Eighteen imaging sessions were conducted in 15 patients (7 women; aged 52.4 ± 14.4 y) with DBS of subthalamic nucleus (n = 6), globus pallidus interna (n = 5), ventro-intermediate (n = 3), or anterior (n = 1) thalamic nucleus and clinically suspected lead displacement. Minimum distance between DBS generator and magnetic field transmitter was kept at 65 cm. The pre-implantation MRI dataset was loaded into the ultrasound system for the fusion imaging examination. The DBS lead position was rated using validated criteria. Generator DBS parameters and neurological state of patients were monitored. Magnetic resonance-ultrasound fusion imaging and volume navigation were feasible in all cases and provided with real-time imaging capabilities of DBS lead and its location within the superimposed magnetic resonance images. Of 35 assessed lead locations, 30 were rated optimal, three suboptimal, and two displaced. In two cases, electrodes were re-implanted after confirming their inappropriate location on computed tomography (CT) scan. No influence of fusion imaging on clinical state of patients, or on DBS implantable pulse generator function, was found. Magnetic resonance-ultrasound real-time fusion imaging of DBS electrodes is safe with distinct precautions and improves assessment of electrode location. It may lower the need for repeated CT or MRI scans in DBS patients. © 2015 International Parkinson and Movement Disorder Society.

  5. Is ultrasound perfusion imaging capable of detecting mismatch? A proof-of-concept study in acute stroke patients.

    PubMed

    Reitmeir, Raluca; Eyding, Jens; Oertel, Markus F; Wiest, Roland; Gralla, Jan; Fischer, Urs; Giquel, Pierre-Yves; Weber, Stefan; Raabe, Andreas; Mattle, Heinrich P; Z'Graggen, Werner J; Beck, Jürgen

    2017-04-01

    In this study, we compared contrast-enhanced ultrasound perfusion imaging with magnetic resonance perfusion-weighted imaging or perfusion computed tomography for detecting normo-, hypo-, and nonperfused brain areas in acute middle cerebral artery stroke. We performed high mechanical index contrast-enhanced ultrasound perfusion imaging in 30 patients. Time-to-peak intensity of 10 ischemic regions of interests was compared to four standardized nonischemic regions of interests of the same patient. A time-to-peak >3 s (ultrasound perfusion imaging) or >4 s (perfusion computed tomography and magnetic resonance perfusion) defined hypoperfusion. In 16 patients, 98 of 160 ultrasound perfusion imaging regions of interests of the ischemic hemisphere were classified as normal, and 52 as hypoperfused or nonperfused. Ten regions of interests were excluded due to artifacts. There was a significant correlation of the ultrasound perfusion imaging and magnetic resonance perfusion or perfusion computed tomography (Pearson's chi-squared test 79.119, p < 0.001) (OR 0.1065, 95% CI 0.06-0.18). No perfusion in ultrasound perfusion imaging (18 regions of interests) correlated highly with diffusion restriction on magnetic resonance imaging (Pearson's chi-squared test 42.307, p < 0.001). Analysis of receiver operating characteristics proved a high sensitivity of ultrasound perfusion imaging in the diagnosis of hypoperfused area under the curve, (AUC = 0.917; p < 0.001) and nonperfused (AUC = 0.830; p < 0.001) tissue in comparison with perfusion computed tomography and magnetic resonance perfusion. We present a proof of concept in determining normo-, hypo-, and nonperfused tissue in acute stroke by advanced contrast-enhanced ultrasound perfusion imaging.

  6. Acoustic Evaluation of Sanders Associates ACODAC Sensors

    DTIC Science & Technology

    1983-03-01

    this securing technique because of its susceptibility to in-band resonances. Although this unit was primarily submitted for sensor flow- noise evaluation...of this sensor and prepare it for the required flow- noise evaluation by replacing the defective geophones in the cosine channel. For completeness...channels displayed essentially flat response with a low frequency roll off starting at about 20 Hz and an upper resonance at 3300 Hz. The sensitivity

  7. Childhood Ependymoma Treatment

    MedlinePlus

    ... a neuro exam or a neurologic exam. MRI (magnetic resonance imaging) with gadolinium : A procedure that uses a magnet, ... the picture. This procedure is also called nuclear magnetic resonance imaging (NMRI). Lumbar puncture : A procedure used to collect ...

  8. Cerebral Cavernous Malformation

    MedlinePlus

    ... and individuals frequently have multiple CCMs found via magnetic resonance imaging. Individuals with CCM are faced with a diagnosis ... and individuals frequently have multiple CCMs found via magnetic resonance imaging. Individuals with CCM are faced with a diagnosis ...

  9. Diagnosing MS

    MedlinePlus

    ... diagnosis or provide additional evidence if it’s necessary. Magnetic Resonance Imaging (MRI) Diagnostic tool that currently offers the most ... Out Learn More Evoked Potentials (EP) Learn More Magnetic Resonance Imaging (MRI) Learn More Cerebrospinal Fluid (CSF) Learn More ...

  10. Shielded Microstrip Array for 7T Human MR Imaging

    PubMed Central

    Wu, Bing; Wang, Chunsheng; Kelley, Douglas A. C.; Xu, Duan; Vigneron, Daniel B.; Nelson, Sarah J.

    2010-01-01

    The high-frequency transceiver array based on the microstrip transmission line design is a promising technique for ultrahigh field magnetic resonance imaging (MRI) signal excitation and reception. However, with the increase of radio-frequency (RF) channels, the size of the ground plane in each microstrip coil element is usually not sufficient to provide a perfect ground. Consequently, the transceiver array may suffer from cable resonance, lower Q-factors, and imaging quality degradations. In this paper, we present an approach to improving the performance of microstrip transceiver arrays by introducing RF shielding outside the microstrip array and the feeding coaxial cables. This improvement reduced interactions among cables, increased resonance stability, and Q-factors, and thus improved imaging quality. An experimental method was also introduced and utilized for quantitative measurement and evaluation of RF coil resonance stability or “cable resonance” behavior. PMID:19822470

  11. Magnetic resonance imaging of breast implants.

    PubMed

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  12. The comparison of multiple F-wave variable studies and magnetic resonance imaging examinations in the assessment of cervical radiculopathy.

    PubMed

    Lin, Chu-Hsu; Tsai, Yuan-Hsiung; Chang, Chia-Hao; Chen, Chien-Min; Hsu, Hung-Chih; Wu, Chun-Yen; Hong, Chang-Zern

    2013-09-01

    The aims of this study were to investigate the correlation of the findings of multiple median and ulnar F-wave variables and magnetic resonance imaging examinations in the prediction of cervical radiculopathy. The data of 68 patients who underwent both nerve conduction studies of the upper extremities and cervical spine magnetic resonance imaging within 3 mos of the nerve conduction studies were retrospectively reviewed and reinterpreted. The associations between multiple median and ulnar F-wave variables (including persistence, chronodispersion, and minimal, maximal, and mean latencies) and magnetic resonance imaging evidence of lower cervical spondylotic radiculopathy (i.e., C7, C8, and T1 radiculopathy) were investigated. Patients with lower cervical radiculopathy exhibited reduced right median F-wave persistence (P = 0.011), increased right ulnar F-wave chronodispersion (P = 0.041), and a trend toward increased left ulnar F-wave chronodispersion (P = 0.059); however, there were no other consistent significant differences in the F-wave variables between patients with and patients without magnetic resonance imaging evidence of lower cervical radiculopathy. In comparison with normal reference values established previously, the sensitivity and positive predictive value of F-wave variable abnormalities for predicting lower cervical radiculopathy were low. There was a low correlation between F-wave studies and magnetic resonance imaging examinations. The diagnostic utility of multiple F-wave variables in the prediction of cervical radiculopathy was not supported by this study.

  13. Magnetic resonance colonography without bowel cleansing: a prospective cross sectional study in a screening population

    PubMed Central

    Kuehle, Christiane A; Langhorst, Jost; Ladd, Susanne C; Zoepf, Thomas; Nuefer, Michael; Grabellus, Florian; Barkhausen, Joerg; Gerken, Guido; Lauenstein, Thomas C

    2007-01-01

    Background and aim To evaluate the diagnostic accuracy of magnetic resonance colonography (MRC) without bowel cleansing in a screening population and compare the results to colonoscopy as a standard of reference. Methods 315 screening patients, older than 50 years with a normal risk profile for colorectal cancer, were included in this study. For MRC, a tagging agent (5.0% Gastrografin, 1.0% barium sulphate, 0.2% locust bean gum) was ingested with each main meal within 2 days prior to MRC. No bowel cleansing was applied. For the magnetic resonance examination, a rectal water enema was administered. Data collection was based on contrast enhanced T1 weighted images and TrueFISP images. Magnetic resonance data were analysed for image quality and the presence of colorectal lesions. Conventional colonoscopy and histopathological samples served as reference. Results In 4% of all colonic segments, magnetic resonance image quality was insufficient because of untagged faecal material. Adenomatous polyps >5 mm were detected by means of MRC, with a sensitivity of 83.0%. Overall specificity was 90.2% (false positive findings in 19 patients). However, only 16 of 153 lesions <5 mm and 9 of 127 hyperplastic polyps could be visualised on magnetic resonance images. Conclusions Faecal tagging MRC is applicable for screening purposes. It provides good accuracy for the detection of relevant (ie, adenomatous) colorectal lesions >5 mm in a screening population. However, refinements to optimise image quality of faecal tagging are needed. PMID:17341542

  14. Semantic Factors Predict the Rate of Lexical Replacement of Content Words

    PubMed Central

    Vejdemo, Susanne; Hörberg, Thomas

    2016-01-01

    The rate of lexical replacement estimates the diachronic stability of word forms on the basis of how frequently a proto-language word is replaced or retained in its daughter languages. Lexical replacement rate has been shown to be highly related to word class and word frequency. In this paper, we argue that content words and function words behave differently with respect to lexical replacement rate, and we show that semantic factors predict the lexical replacement rate of content words. For the 167 content items in the Swadesh list, data was gathered on the features of lexical replacement rate, word class, frequency, age of acquisition, synonyms, arousal, imageability and average mutual information, either from published databases or gathered from corpora and lexica. A linear regression model shows that, in addition to frequency, synonyms, senses and imageability are significantly related to the lexical replacement rate of content words–in particular the number of synonyms that a word has. The model shows no differences in lexical replacement rate between word classes, and outperforms a model with word class and word frequency predictors only. PMID:26820737

  15. General Anesthesia Inhibits the Activity of the “Glymphatic System”

    PubMed Central

    Gakuba, Clement; Gaberel, Thomas; Goursaud, Suzanne; Bourges, Jennifer; Di Palma, Camille; Quenault, Aurélien; Martinez de Lizarrondo, Sara; Vivien, Denis; Gauberti, Maxime

    2018-01-01

    INTRODUCTION: According to the “glymphatic system” hypothesis, brain waste clearance is mediated by a continuous replacement of the interstitial milieu by a bulk flow of cerebrospinal fluid (CSF). Previous reports suggested that this cerebral CSF circulation is only active during general anesthesia or sleep, an effect mediated by the dilatation of the extracellular space. Given the controversies regarding the plausibility of this phenomenon and the limitations of currently available methods to image the glymphatic system, we developed original whole-brain in vivo imaging methods to investigate the effects of general anesthesia on the brain CSF circulation. METHODS: We used magnetic resonance imaging (MRI) and near-infrared fluorescence imaging (NIRF) after injection of a paramagnetic contrast agent or a fluorescent dye in the cisterna magna, in order to investigate the impact of general anesthesia (isoflurane, ketamine or ketamine/xylazine) on the intracranial CSF circulation in mice. RESULTS: In vivo imaging allowed us to image CSF flow in awake and anesthetized mice and confirmed the existence of a brain-wide CSF circulation. Contrary to what was initially thought, we demonstrated that the parenchymal CSF circulation is mainly active during wakefulness and significantly impaired during general anesthesia. This effect was especially significant when high doses of anesthetic agent were used (3% isoflurane). These results were consistent across the different anesthesia regimens and imaging modalities. Moreover, we failed to detect a significant change in the brain extracellular water volume using diffusion weighted imaging in awake and anesthetized mice. CONCLUSION: The parenchymal diffusion of small molecular weight compounds from the CSF is active during wakefulness. General anesthesia has a negative impact on the intracranial CSF circulation, especially when using a high dose of anesthetic agent. PMID:29344300

  16. General Anesthesia Inhibits the Activity of the "Glymphatic System".

    PubMed

    Gakuba, Clement; Gaberel, Thomas; Goursaud, Suzanne; Bourges, Jennifer; Di Palma, Camille; Quenault, Aurélien; de Lizarrondo, Sara Martinez; Vivien, Denis; Gauberti, Maxime

    2018-01-01

    INTRODUCTION: According to the "glymphatic system" hypothesis, brain waste clearance is mediated by a continuous replacement of the interstitial milieu by a bulk flow of cerebrospinal fluid (CSF). Previous reports suggested that this cerebral CSF circulation is only active during general anesthesia or sleep, an effect mediated by the dilatation of the extracellular space. Given the controversies regarding the plausibility of this phenomenon and the limitations of currently available methods to image the glymphatic system, we developed original whole-brain in vivo imaging methods to investigate the effects of general anesthesia on the brain CSF circulation. METHODS: We used magnetic resonance imaging (MRI) and near-infrared fluorescence imaging (NIRF) after injection of a paramagnetic contrast agent or a fluorescent dye in the cisterna magna, in order to investigate the impact of general anesthesia (isoflurane, ketamine or ketamine/xylazine) on the intracranial CSF circulation in mice. RESULTS: In vivo imaging allowed us to image CSF flow in awake and anesthetized mice and confirmed the existence of a brain-wide CSF circulation. Contrary to what was initially thought, we demonstrated that the parenchymal CSF circulation is mainly active during wakefulness and significantly impaired during general anesthesia. This effect was especially significant when high doses of anesthetic agent were used (3% isoflurane). These results were consistent across the different anesthesia regimens and imaging modalities. Moreover, we failed to detect a significant change in the brain extracellular water volume using diffusion weighted imaging in awake and anesthetized mice. CONCLUSION: The parenchymal diffusion of small molecular weight compounds from the CSF is active during wakefulness. General anesthesia has a negative impact on the intracranial CSF circulation, especially when using a high dose of anesthetic agent.

  17. A guide for effective anatomical vascularization studies: useful ex vivo methods for both CT and MRI imaging before dissection.

    PubMed

    Renard, Yohann; Hossu, Gabriela; Chen, Bailiang; Krebs, Marine; Labrousse, Marc; Perez, Manuela

    2018-01-01

    The objective of this study was to develop a simple and useful injection protocol for imaging cadaveric vascularization and dissection. Mixtures of contrast agent and cast product should provide adequate contrast for two types of ex vivo imaging (MRI and CT) and should harden to allow gross dissection of the injected structures. We tested the most popular contrast agents and cast products, and selected the optimal mixture composition based on their availability and ease of use. All mixtures were first tested in vitro to adjust dilution parameters of each contrast agent and to fine-tune MR imaging acquisition sequences. Mixtures were then injected in 24 pig livers and one human pancreas for MR and computed tomography (CT) imaging before anatomical dissection. Colorized latex, gadobutrol and barite mixture met the above objective. Mixtures composed of copper sulfate (CuSO 4 ) gadoxetic acid (for MRI) and iodine (for CT) gave an inhomogeneous signal or extravasation of the contrast agent. Agar did not harden sufficiently for gross dissection but appears useful for CT and magnetic resonance imaging (MRI) studies without dissection. Silicone was very hard to inject but achieved the goals of the study. Resin is particularly difficult to use but could replace latex as an alternative for corrosion instead of dissection. This injection protocol allows CT and MRI images to be obtained of cadaveric vascularization and anatomical casts in the same anatomic specimen. Post-imaging processing software allow easy 3D reconstruction of complex anatomical structures using this technique. Applications are numerous, e.g. surgical training, teaching methods, postmortem anatomic studies, pathologic studies, and forensic diagnoses. © 2017 Anatomical Society.

  18. Regularized Reconstruction of Dynamic Contrast-Enhanced MR Images for Evaluation of Breast Lesions

    DTIC Science & Technology

    2011-01-01

    Magnetic resonance imaging contrast-enhanced relaxometry of breast tumors: an MRI multicenter investigation concerning 100 patients,” Mag. Res. Im., vol...The overall goal of this project was to develop, implement, and evaluate methods for im- proving image quality in dynamic magnetic resonance imaging ...Olafsson, H. R. Shi, and D. C. Noll, “Toeplitz-based iterative image reconstruction for MRI with correction for magnetic field inhomogeneity,” IEEE

  19. Magnetic resonance imaging as a tool for extravehicular activity analysis

    NASA Technical Reports Server (NTRS)

    Dickenson, R.; Lorenz, C.; Peterson, S.; Strauss, A.; Main, J.

    1992-01-01

    The purpose of this research is to examine the value of magnetic resonance imaging (MRI) as a means of conducting kinematic studies of the hand for the purpose of EVA capability enhancement. After imaging the subject hand using a magnetic resonance scanner, the resulting 2D slices were reconstructed into a 3D model of the proximal phalanx of the left hand. Using the coordinates of several landmark positions, one is then able to decompose the motion of the rigid body. MRI offers highly accurate measurements due to its tomographic nature without the problems associated with other imaging modalities for in vivo studies.

  20. Magnetic resonance imaging without field cycling at less than earth's magnetic field

    NASA Astrophysics Data System (ADS)

    Lee, Seong-Joo; Shim, Jeong Hyun; Kim, Kiwoong; Yu, Kwon Kyu; Hwang, Seong-min

    2015-03-01

    A strong pre-polarization field, usually tenths of a milli-tesla in magnitude, is used to increase the signal-to-noise ratio in ordinary superconducting quantum interference device-based nuclear magnetic resonance/magnetic resonance imaging experiments. Here, we introduce an experimental approach using two techniques to remove the need for the pre-polarization field. A dynamic nuclear polarization (DNP) technique enables us to measure an enhanced resonance signal. In combination with a π / 2 pulse to avoid the Bloch-Siegert effect in a micro-tesla field, we obtained an enhanced magnetic resonance image by using DNP technique with a 34.5 μT static external magnetic field without field cycling. In this approach, the problems of eddy current and flux trapping in the superconducting pickup coil, both due to the strong pre-polarization field, become negligible.

  1. Nuclear Magnetic Resonance Nondestructive Evaluation of Composite Materials

    DTIC Science & Technology

    1990-04-09

    Pat. Appl. EP 26265, 8 Apr 1981, 13 pp. (1981). 9. A. N. Garroway , J. Baum, M. G. Munowitz, and A. Pines, NMR Imaging in Solids by Multiple-Quantum...Resonance, J. Magn. Reson. 60(2), 337-41 (1984). 10. J. Baum, A. N. Garroway , M. Munowitz, and A. Pines, Multiple-Quantum NMR in Solids: Application to... Garroway , NMR Images of Solids, J. Magn. Reson. 66(3), 530-5 (1986). 28. J. B. Miller and A. N. Garroway , Removal of Static Field Inhomogeneity and

  2. Radiation-Induced Liver Injury Mimicking Metastatic Disease in a Patient With Esophageal Cancer: Correlation of Positron Emission Tomography/Computed Tomography With Magnetic Resonance Imaging and Literature Review.

    PubMed

    Rabe, Tiffany M; Yokoo, Takeshi; Meyer, Jeffrey; Kernstine, Kemp H; Wang, David; Khatri, Gaurav

    2016-01-01

    Post-radiation therapy evaluation of distal esophageal cancers with positron emission tomography/computed tomography can be problematic. Differentiation of recurrent neoplasm from postradiation changes is difficult in areas of fluorodeoxyglucose avidity in adjacent, incidentally irradiated organs. Few studies have described the magnetic resonance imaging appearance of radiation-induced hepatic injury. We report a case of focal radiation-induced liver injury with a new focus of fluorodeoxyglucose uptake on posttreatment positron emission tomography as well as masslike enhancement and signal abnormality on magnetic resonance imaging, thus mimicking new liver metastasis. Correlation with radiation planning images suggested the correct diagnosis, which was confirmed on follow-up imaging.

  3. Fabrication and characterization of polymer gel for MRI phantom with embedded lesion particles

    NASA Astrophysics Data System (ADS)

    In, Eunji; Naguib, Hani E.; Haider, Masoom

    2012-04-01

    Magnetic Resonance Imaging (MRI) is a medical imaging technique used in radiology to visualize the detailed internal structure and body soft tissues in complete 3D image. MRI performs best when optimal imaging parameters such as contrast, signal to noise ratio (SNR), spatial resolution and total scan time are utilized. However, due to a variety of imaging parameters that differ with the manufacturer, a calibration medium that allows the control of these parameters is necessary. Therefore, a phantom that behaves similar to human soft tissue is developed to replace a real human. Polymer gel is novel material that has great potential in the medical imaging. Since very few have focused on examining the behavior of polymer lesions, the motivation of this study is to develop a polymer gel phantom, especially for liver, with embedded lesions. Both the phantom and lesions should be capable of reflecting T1 and T2 relaxation values through various characterization processes. In this paper, phantom and lesion particles were fabricated with carrageenan as a gelling agent by physical aggregation. Agar was used as supplementary gelling agent and T2 modifier and Gd-DTPA as T1 modifier. The polymer gel samples were fabricated by varying the concentrations of the gelling agent, and T1 and T2 modifiers. The lesion particles were obtained by extracting molten polymer gel solution in chilled oil bath to obtain spherical shape. The polymer gel properties including density, elastic modulus, dielectric constant and optical properties were measured to compare with human tissue values for long period of time.

  4. Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Tze Yee

    Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisitionmore » with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.« less

  5. Imaging Algorithms for Evaluating Suspected Rotator Cuff Disease: Society of Radiologists in Ultrasound Consensus Conference Statement

    PubMed Central

    Jacobson, Jon A.; Benson, Carol B.; Bancroft, Laura W.; Bedi, Asheesh; McShane, John M.; Miller, Theodore T.; Parker, Laurence; Smith, Jay; Steinbach, Lynne S.; Teefey, Sharlene A.; Thiele, Ralf G.; Tuite, Michael J.; Wise, James N.; Yamaguchi, Ken

    2013-01-01

    The Society of Radiologists in Ultrasound convened a panel of specialists from a variety of medical disciplines to reach a consensus about the recommended imaging evaluation of painful shoulders with clinically suspected rotator cuff disease. The panel met in Chicago, Ill, on October 18 and 19, 2011, and created this consensus statement regarding the roles of radiography, ultrasonography (US), computed tomography (CT), CT arthrography, magnetic resonance (MR) imaging, and MR arthrography. The consensus panel consisted of two co-moderators, a facilitator, a statistician and health care economist, and 10 physicians who have specialty expertise in shoulder pain evaluation and/or treatment. Of the 13 physicians on the panel, nine were radiologists who were chosen to represent a broad range of skill sets in diagnostic imaging, different practice types (private and academic), and different geographical regions of the United States. Five of the radiologists routinely performed musculoskeletal US as part of their practice and four did not. There was also one representative from each of the following clinical specialties: rheumatology, physical medicine and rehabilitation, orthopedic surgery, and nonoperative sports medicine. The goal of this conference was to construct several algorithms with which to guide the imaging evaluation of suspected rotator cuff disease in patients with a native rotator cuff, patients with a repaired rotator cuff, and patients who have undergone shoulder replacement. The panel hopes that these recommendations will lead to greater uniformity in rotator cuff imaging and more cost-effective care for patients suspected of having rotator cuff abnormality. © RSNA, 2013 PMID:23401583

  6. Off-resonance artifacts correction with convolution in k-space (ORACLE).

    PubMed

    Lin, Wei; Huang, Feng; Simonotto, Enrico; Duensing, George R; Reykowski, Arne

    2012-06-01

    Off-resonance artifacts hinder the wider applicability of echo-planar imaging and non-Cartesian MRI methods such as radial and spiral. In this work, a general and rapid method is proposed for off-resonance artifacts correction based on data convolution in k-space. The acquired k-space is divided into multiple segments based on their acquisition times. Off-resonance-induced artifact within each segment is removed by applying a convolution kernel, which is the Fourier transform of an off-resonance correcting spatial phase modulation term. The field map is determined from the inverse Fourier transform of a basis kernel, which is calibrated from data fitting in k-space. The technique was demonstrated in phantom and in vivo studies for radial, spiral and echo-planar imaging datasets. For radial acquisitions, the proposed method allows the self-calibration of the field map from the imaging data, when an alternating view-angle ordering scheme is used. An additional advantage for off-resonance artifacts correction based on data convolution in k-space is the reusability of convolution kernels to images acquired with the same sequence but different contrasts. Copyright © 2011 Wiley-Liss, Inc.

  7. [Analysis of Cost-effectiveness of screening for breast cancer with conventional mammography, digital and magnetic resonance imaging].

    PubMed

    Peregrino, Antonio Augusto de Freitas; Vianna, Cid Manso de Mello; de Almeida, Carlos Eduardo Veloso; Gonzáles, Gabriela Bittencourt; Machado, Samara Cristina Ferreira; Costa e Silva, Frances Valéria; Rodrigues, Marcus Paulo da Silva

    2012-01-01

    A cost-effectiveness analysis was conducted in screening for breast cancer. The use of conventional mammography, digital and magnetic resonance imaging were compared with natural disease history as a baseline. A Markov model projected breast cancer in a group of 100,000 women for a 30 year period, with screening every two years. Four distinct scenarios were modeled: (1) the natural history of breast cancer, as a baseline, (2) conventional film mammography, (3) digital mammography and (4) magnetic resonance imaging. The costs of the scenarios modeled ranged from R$ 194.216,68 for natural history, to R$ 48.614.338,31, for screening with magnetic resonance imaging. The difference in effectiveness between the interventions ranged from 300 to 78.000 years of life gained in the cohort. The ratio of incremental cost-effectiveness in terms of cost per life-year gains, conventional mammographic screening has produced an extra year for R$ 13.573,07. The ICER of magnetic resonance imaging was R$ 2.904.328,88, compared to no screening. In conclusion, it is more cost-effective to perform the screening with conventional mammography than other technological interventions.

  8. Optimal Control-Enabled Imaging and Spectroscopy using a Nanowire Magnetic Resonance Force Microscope

    NASA Astrophysics Data System (ADS)

    Rose, William; Haas, Holger; Chen, Angela; Cory, David; Budakian, Raffi

    Magnetic resonance imaging (MRI) is a powerful non-invasive technique that has transformed our ability to study the structure and function of biological systems. Key to its success has been the unique ability to combine imaging with magnetic resonance spectroscopy. Although it remains a significant challenge, there is considerable interest in extending MRI spectroscopy to the nanometer scale because it would provide a fundamentally new route for determining the structure and function of complex biomolecules. We present data taken with a nanowire magnetic resonance force microscopy (MRFM) setup. We show how the capabilities of this very sensitive spin-detection system can be extended to include spectroscopy and nanometer-scale imaging by combining optimal control theory (OCT) techniques with magic echo sequences. We apply OCT-based dynamical-decoupling pulses to nanoscale ensembles of proton spins in polystyrene, and demonstrate a 500-fold line-narrowing of the proton spin resonance, from 30 kHz to 60 Hz. We further demonstrate 1-D imaging over a 35-nm region with an average voxel size of 2.2 nm. Funding provided by the U.S. Army Research Office, Grant No. W911NF-12-1-0341.

  9. A Scalable Framework For Segmenting Magnetic Resonance Images

    PubMed Central

    Hore, Prodip; Goldgof, Dmitry B.; Gu, Yuhua; Maudsley, Andrew A.; Darkazanli, Ammar

    2009-01-01

    A fast, accurate and fully automatic method of segmenting magnetic resonance images of the human brain is introduced. The approach scales well allowing fast segmentations of fine resolution images. The approach is based on modifications of the soft clustering algorithm, fuzzy c-means, that enable it to scale to large data sets. Two types of modifications to create incremental versions of fuzzy c-means are discussed. They are much faster when compared to fuzzy c-means for medium to extremely large data sets because they work on successive subsets of the data. They are comparable in quality to application of fuzzy c-means to all of the data. The clustering algorithms coupled with inhomogeneity correction and smoothing are used to create a framework for automatically segmenting magnetic resonance images of the human brain. The framework is applied to a set of normal human brain volumes acquired from different magnetic resonance scanners using different head coils, acquisition parameters and field strengths. Results are compared to those from two widely used magnetic resonance image segmentation programs, Statistical Parametric Mapping and the FMRIB Software Library (FSL). The results are comparable to FSL while providing significant speed-up and better scalability to larger volumes of data. PMID:20046893

  10. Brain Morphometry Using Anatomical Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Bansal, Ravi; Gerber, Andrew J.; Peterson, Bradley S.

    2008-01-01

    The efficacy of anatomical magnetic resonance imaging (MRI) in studying the morphological features of various regions of the brain is described, also providing the steps used in the processing and studying of the images. The ability to correlate these features with several clinical and psychological measures can help in using anatomical MRI to…

  11. Identification of disappearing brain lesions with intraoperative magnetic resonance imaging prevents surgery.

    PubMed

    Sutherland, Christina S; Kelly, John Jp; Morrish, William; Sutherland, Garnette R

    2010-10-01

    Typically, neurosurgery is performed several weeks after diagnostic imaging. In the majority of cases, histopathology confirms the diagnosis of neoplasia. In a small number of cases, a different diagnosis is established or histopathology is nondiagnostic. The frequency with which these outcomes occur has not been established. To determine the frequency and outcome of disappearing brain lesions within a group of patients undergoing surgery for suspected brain tumor. Over the past decade, 982 patients were managed in the intraoperative magnetic resonance imaging unit at the University of Calgary, Calgary, Alberta, Canada. These patients have been prospectively evaluated. In 652 patients, a brain tumor was suspected. In 6 of the 652 patients, histopathology indicated a nontumor diagnosis. In 5 patients, intraoperative images, acquired after induction of anesthesia, showed complete or nearly complete resolution of the suspected tumor identified on diagnostic magnetic resonance imaging acquired 6 ± 4 (mean ± SD) weeks previously. Anesthesia was reversed, and the surgical procedure aborted. The lesions have not progressed with 6 ± 2 years of follow-up. Intraoperative magnetic resonance imaging prevented surgery on 5 patients with disappearing lesions.

  12. Optically trapped atomic resonant devices for narrow linewidth spectral imaging

    NASA Astrophysics Data System (ADS)

    Qian, Lipeng

    This thesis focuses on the development of atomic resonant devices for spectroscopic applications. The primary emphasis is on the imaging properties of optically thick atomic resonant fluorescent filters and their applications. In addition, this thesis presents a new concept for producing very narrow linewidth light as from an atomic vapor lamp pumped by a nanosecond pulse system. This research was motivated by application for missile warning system, and presents an innovative approach to a wide angle, ultra narrow linewidth imaging filter using a potassium vapor cell. The approach is to image onto and collect the fluorescent photons emitted from the surface of an optically thick potassium vapor cell, generating a 2 GHz pass-band imaging filter. This linewidth is narrow enough to fall within a Fraunhefer dark zone in the solar spectrum, thus make the detection solar blind. Experiments are conducted to measure the absorption line shape of the potassium resonant filter, the quantum efficiency of the fluorescent behavior, and the resolution of the fluorescent image. Fluorescent images with different spatial frequency components are analyzed by using a discrete Fourier transform, and the imaging capability of the fluorescent filter is described by its Modulation Transfer Function. For the detection of radiation that is spectrally broader than the linewidth of the potassium imaging filter, the fluorescent image is seen to be blurred by diffuse fluorescence from the slightly off resonant photons. To correct this, an ultra-thin potassium imaging filter is developed and characterized. The imaging property of the ultra-thin potassium imaging cell is tested with a potassium seeded flame, yielding a resolution image of ˜ 20 lines per mm. The physics behind the atomic resonant fluorescent filter is radiation trapping. The diffusion process of the resonant photons trapped in the atomic vapor is theoretically described in this thesis. A Monte Carlo method is used to simulate the absorption and fluorescence. The optimum resolution of the fluorescent image is predicted by simulation. Radiation trapping is also shown to be useful for the generation of ultra-narrow linewidth light from an atomic vapor flash lamp. A 2 nanosecond, high voltage pulse is used to excite low pressure mercury vapor mixed with noble gases, producing high intensity emission at the mercury resonant line at 253.7 nm. With a nanosecond pumping time and high electrical current, the radiation intensity of the mercury discharge is increased significantly compared to a normal glow discharge lamp, while simultaneously suppressing the formation of an arc discharge. By avoiding the arc discharge, discrete spectral lines of mercury were kept at narrow bandwidth. Due to radiation trapping, the emission linewidth from the nanosecond mercury lamp decreases with time and produces ultra-narrow linewidth emission 100 ns after of the excitation, this linewidth is verified by absorption measurements through low pressure mercury absorption filter. The lamp is used along with mercury absorption filters for spectroscopic applications, including Filtered Rayleigh Scattering with different CO2 pressures and Raman scattering from methanol.

  13. Clinical, pathological, and neuroimaging analyses of two cases of Leigh syndrome in a Chinese family.

    PubMed

    Jin, Taoran; Shen, Hongrui; Zhao, Zhe; Hu, Jing

    2014-11-01

    In this study, the authors examined the clinical manifestations, skeletal muscle pathological characteristics, and neuroimaging results of 2 cases of Leigh syndrome in a Chinese family. The 2 patients presented with general weakness, and 1 of them presented with an impairment of vision. Skeletal muscle biopsies showed a deficiency in cytochrome c oxidase levels. Brain magnetic resonance imaging showed increased T1 and T2 signal intensities in the centrum ovale and dentate nucleus. Diffusion-weighted imaging showed a high-intensity signal. Magnetic resonance spectroscopy showed elevated levels of lactic acid in lesions. The examination of 1 patient at disease onset and during disease remission showed that the lesions detected by magnetic resonance imaging and diffusion-weighted imaging, and the peak for lactic acid detected by magnetic resonance spectroscopy, decreased during remission. These data suggest that changes in the imaging results of patients with Leigh syndrome correlate with disease course and pathogenetic condition. © The Author(s) 2014.

  14. Imaging of brain metastases.

    PubMed

    Fink, Kathleen R; Fink, James R

    2013-01-01

    Imaging plays a key role in the diagnosis of central nervous system (CNS) metastasis. Imaging is used to detect metastases in patients with known malignancies and new neurological signs or symptoms, as well as to screen for CNS involvement in patients with known cancer. Computed tomography (CT) and magnetic resonance imaging (MRI) are the key imaging modalities used in the diagnosis of brain metastases. In difficult cases, such as newly diagnosed solitary enhancing brain lesions in patients without known malignancy, advanced imaging techniques including proton magnetic resonance spectroscopy (MRS), contrast enhanced magnetic resonance perfusion (MRP), diffusion weighted imaging (DWI), and diffusion tensor imaging (DTI) may aid in arriving at the correct diagnosis. This image-rich review discusses the imaging evaluation of patients with suspected intracranial involvement and malignancy, describes typical imaging findings of parenchymal brain metastasis on CT and MRI, and provides clues to specific histological diagnoses such as the presence of hemorrhage. Additionally, the role of advanced imaging techniques is reviewed, specifically in the context of differentiating metastasis from high-grade glioma and other solitary enhancing brain lesions. Extra-axial CNS involvement by metastases, including pachymeningeal and leptomeningeal metastases is also briefly reviewed.

  15. Nonlinearization and waves in bounded media: old wine in a new bottle

    NASA Astrophysics Data System (ADS)

    Mortell, Michael P.; Seymour, Brian R.

    2017-02-01

    We consider problems such as a standing wave in a closed straight tube, a self-sustained oscillation, damped resonance, evolution of resonance and resonance between concentric spheres. These nonlinear problems, and other similar ones, have been solved by a variety of techniques when it is seen that linear theory fails. The unifying approach given here is to initially set up the appropriate linear difference equation, where the difference is the linear travel time. When the linear travel time is replaced by a corrected nonlinear travel time, the nonlinear difference equation yields the required solution.

  16. Unwarping confocal microscopy images of bee brains by nonrigid registration to a magnetic resonance microscopy image.

    PubMed

    Rohlfing, Torsten; Schaupp, Frank; Haddad, Daniel; Brandt, Robert; Haase, Axel; Menzel, Randolf; Maurer, Calvin R

    2005-01-01

    Confocal microscopy (CM) is a powerful image acquisition technique that is well established in many biological applications. It provides 3-D acquisition with high spatial resolution and can acquire several different channels of complementary image information. Due to the specimen extraction and preparation process, however, the shapes of imaged objects may differ considerably from their in vivo appearance. Magnetic resonance microscopy (MRM) is an evolving variant of magnetic resonance imaging, which achieves microscopic resolutions using a high magnetic field and strong magnetic gradients. Compared to CM imaging, MRM allows for in situ imaging and is virtually free of geometrical distortions. We propose to combine the advantages of both methods by unwarping CM images using a MRM reference image. Our method incorporates a sequence of image processing operators applied to the MRM image, followed by a two-stage intensity-based registration to compute a nonrigid coordinate transformation between the CM images and the MRM image. We present results obtained using CM images from the brains of 20 honey bees and a MRM image of an in situ bee brain. Copyright 2005 Society of Photo-Optical Instrumentation Engineers.

  17. Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.

    PubMed

    Chen, Weitian; Sica, Christopher T; Meyer, Craig H

    2008-11-01

    Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of correcting for B0 inhomogeneity and concomitant gradients simultaneously. The method is a fast alternative to conjugate phase reconstruction, with the off-resonance phase term approximated by Chebyshev polynomials. The proposed algorithm is well suited for semiautomatic off-resonance correction, which works well even with an inaccurate or low-resolution field map. The proposed algorithm is demonstrated using phantom and in vivo data sets acquired by spiral scanning. Semiautomatic off-resonance correction alone is shown to provide a moderate amount of correction for concomitant gradient field effects, in addition to B0 imhomogeneity effects. However, better correction is provided by the proposed combined method. The best results were produced using the semiautomatic version of the proposed combined method.

  18. Malformations of cortical development: 3T magnetic resonance imaging features

    PubMed Central

    Battal, Bilal; Ince, Selami; Akgun, Veysel; Kocaoglu, Murat; Ozcan, Emrah; Tasar, Mustafa

    2015-01-01

    Malformation of cortical development (MCD) is a term representing an inhomogeneous group of central nervous system abnormalities, referring particularly to embriyological aspect as a consequence of any of the three developmental stages, i.e., cell proliferation, cell migration and cortical organization. These include cotical dysgenesis, microcephaly, polymicrogyria, schizencephaly, lissencephaly, hemimegalencephaly, heterotopia and focal cortical dysplasia. Since magnetic resonance imaging is the modality of choice that best identifies the structural anomalies of the brain cortex, we aimed to provide a mini review of MCD by using 3T magnetic resonance scanner images. PMID:26516429

  19. Midbrain and spinal cord magnetic resonance imaging (MRI) changes in poliomyelitis.

    PubMed

    Choudhary, Anita; Sharma, Suvasini; Sankhyan, Naveen; Gulati, Sheffali; Kalra, Veena; Banerjee, Bidisha; Kumar, Atin

    2010-04-01

    Poliomyelitis, though eradicated from most parts of the world, continues to occur in India. There is paucity of data on the magnetic resonance imaging (MRI) changes in poliomyelitis. We report a 3(1/2)-year-old boy who presented with subacute onset flaccid paralysis and altered sensorium. Stool culture was positive for wild polio virus type 3. Magnetic resonance imaging revealed signal changes in bilateral substantia nigra and anterior horns of the spinal cord. These MRI changes may be of potential diagnostic significance in a child with poliomyelitis.

  20. Use of cardiac magnetic resonance imaging to evaluate cardiac structure, function and fibrosis in children with infantile Pompe disease on enzyme replacement therapy.

    PubMed

    Barker, Piers C A; Pasquali, Sara K; Darty, Stephen; Ing, Richard J; Li, Jennifer S; Kim, Raymond J; DeArmey, Stephanie; Kishnani, Priya S; Campbell, Michael J

    2010-12-01

    Pompe disease (acid α-glucosidase deficiency) is one of several lysosomal storage diseases amenable to treatment with enzyme replacement therapy (ERT). While echocardiography (echo) has been the standard method to evaluate the cardiac response to ERT, cardiac magnetic resonance imaging (CMR) has the advantage of a better tissue definition and characterization of myocardial fibrosis. However, CMR for Pompe disease is not frequently performed due to a high risk of sedation. We report the first use of CMR in a feasible protocol to quantify left ventricular (LV) mass, function, and the presence of myocardial fibrosis in the Pompe population. Children with Pompe disease on ERT were assessed with transthoracic echo and CMR over a 3 year period at a single institution. Echocardiography was performed using standard techniques without sedation. CMR was performed using retrospectively gated and real-time imaging, with and without sedation. LV mass indexed to body surface area (LVMI) and ejection fraction (EF) were measured by both echo and CMR, and evaluated for change over time. Myocardial fibrosis was assessed by CMR with delayed enhancement imaging 5-10 min after gadolinium contrast using single shot inversion recovery sequences with inversion time set to null the signal from normal myocardium. Seventeen CMR scans were successfully performed in 10 subjects with Pompe disease (median age at first CMR is 9 months, range 1-38 months, 80% male), with sedation only performed in 4 studies. There was a median interval of 5 months (range 0-34 months) from the start of ERT to first CMR (baseline). At baseline, the median indexed LVMI by CMR (140.0 g/m(2), range 43.8-334.0) tended to be lower than that assessed by echo (median 204.0 g/m(2), range 52.0-385.0), but did not reach statistical significance. At baseline, CMR EF was similar to that assessed by echo (55% vs. 55%). Overall, there was no significant decrease in CMR measured LVMI over time (CMR median LVMI at baseline 94 g/m(2) (range 43.8-334) vs. CMR median at most recent study 44.5 g/m(2) (range 34-303), p=0.44). In 5 patients with serial CMR scans over time, LVMI decreased in 2, was similar in 2, and increased in 1 patient with high sustained antibodies to exogenous enzyme. Delayed enhancement was noted in only l separate patient who also had high sustained antibodies to exogenous enzyme. CMR is an imaging tool that is feasible to use to serially follow LVMI and EF in children with Pompe disease on ERT. Real-time imaging is adequate for quantification purposes in these patients and minimizes the need for sedation. Quantitative CMR LVMI is generally lower than echo derived LVMI. Delayed enhancement appears to be a rare finding by CMR in Pompe disease. A further follow-up is necessary to better understand the long term effects of ERT in infantile Pompe survivors, especially those with high sustained antibody titers or advanced cardiac disease at treatment outset. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. Use of Cardiac Magnetic Resonance Imaging to Evaluate Cardiac Structure, Function and Fibrosis in Children with Infantile Pompe Disease on Enzyme Replacement Therapy

    PubMed Central

    Barker, Piers C.A.; Pasquali, Sara K.; Darty, Stephen; Ing, Richard J.; Li, Jennifer S.; Kim, Raymond J.; DeArmey, Stephanie; Kishnani, Priya S.; Campbell, Michael J.

    2010-01-01

    Background Pompe disease (acid α-glucosidase deficiency) is one of several lysosomal storage diseases amenable to treatment with enzyme replacement therapy (ERT). While echocardiography (echo) has been the standard method to evaluate the cardiac response to ERT, cardiac magnetic resonance imaging (CMR) has the advantage of better tissue definition and characterization of myocardial fibrosis. However, CMR for Pompe disease is not frequently performed due to the high risk of sedation. We report the first use of CMR in a feasible protocol to quantify left ventricular (LV) mass, function, and presence of myocardial fibrosis in the Pompe population. Methods Children with Pompe disease on ERT were assessed with transthoracic echo and CMR over a 3 year period at a single institution. Echocardiography was performed using standard techniques without sedation. CMR was performed using retrospectively gated and real-time imaging, with and without sedation. LV mass indexed to body surface area (LVMI) and ejection fraction (EF) were measured by both echo and CMR, and evaluated for change over time. Myocardial fibrosis was assessed with CMR by delayed enhancement imaging 5-10 min after gadolinium contrast using single-shot inversion recovery sequences with inversion time set to null the myocardium. Results Seventeen CMR scans were successfully performed in 10 subjects with Pompe disease (median age at first CMR 9 months, range 1-38 months, 80% male), with sedation only performed for 4 studies. There was a median interval of 5 months (range 0-34 months) from start of ERT to first CMR (baseline). At baseline, median indexed LVMI by CMR (140.0 g/m2, range 43.8-334.0) tended to be lower than that assessed by echo (median 204.0 g/m2, range 52.0-385.0), but did not reach statistical significance. At baseline, CMR EF was similar to that assessed by echo (55% vs. 55%). Overall, there was not a significant decrease in CMR measured LVMI over time (CMR median LVMI at baseline 94 g/m2 (range 43.8-334) vs. CMR median at most recent study 44.5 g/m2 (range 34-303), p=0.44). In 5 patients with serial CMR scans over time, LVMI decreased in 2, was similar in 2, and increased in 1 patient with high sustained antibodies to exogenous enzyme. Delayed enhancement was noted in only l separate patient who also had high sustained antibodies to exogenous enzyme. Conclusion CMR is a useful imaging tool that is feasible to use to serially follow LVMI and EF in children with Pompe disease on ERT. Real-time imaging is adequate for quantification purposes in these patients and minimizes the need for sedation. Quantitative CMR LVMI is generally lower than echo derived LVMI. Delayed enhancement appears to be a rare finding by CMR in Pompe Disease. Further follow-up is necessary to better understand the long term effects of ERT in infantile Pompe survivors, especially those with high sustained antibody titers or advanced cardiac disease at treatment outset. PMID:20875764

  2. A Robust Magnetic Resonance Imager For Ground and Flight Based Measurements of Fluid Physics Phenomena

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Nuclear magnetic resonance (NMR) is a powerful and versatile, noninvasive method for studying fluid transport problems, However, its applications to these types of investigations have been limited. A primary factor that limits the application of NMR has been the lack of a user-friendly, versatile, and inexpensive NMR imaging apparatus that can be used by scientists who are not familiar with sophisticated NMR. To rectify this situation, we developed a user-friendly, NMR imager for projects of relevance to the MRD science community. To that end, we performed preliminary collaborative experiments between NASA, NCMR, and New Mexico Resonance in the high field NMR set up at New Mexico Resonance to track wetting front dynamics in foams under gravity. The experiments were done in a 30 cm, 1.9T Oxford magnet with a TECMAG Libra spectrometer (Tecmag, Inc., Houston, TX). We used two different imaging strategies depending on whether the water in the foam sample was static or moving. Stationary water distributions were imaged with the standard Fourier imaging method, as used in medical MRI, in which data are acquired from all parts of the region of interest at all times and Fourier transformed into a static spatial image.

  3. Radiologic Assessment of Patellofemoral Pain in the Athlete

    PubMed Central

    Endo, Yoshimi; Stein, Beth E. Shubin; Potter, Hollis G.

    2011-01-01

    Context: Although disorders of the patellofemoral joint are common in the athlete, their management can be challenging and require a thorough physical examination and radiologic evaluation, including advanced magnetic resonance imaging techniques. Evidence Acquisition: Relevant articles were searched under OVID and MEDLINE (1968 to 2010) using the keywords patellofemoral joint, patellofemoral pain or patella and radiography, imaging, or magnetic resonance imaging, and the referenced sources were reviewed for additional articles. The quality and validity of the studies were assessed on the basis of careful analysis of the materials and methods before their inclusion in this article. Results: Physical examination and imaging evaluation including standard radiographs are crucial in identifying evidence of malalignment or instability. Magnetic resonance imaging provides valuable information about concomitant soft tissue injuries to the medial stabilizers as well as injuries to the articular cartilage, including chondral shears and osteochondral fractures. Quantitative magnetic resonance imaging assessing the ultrastructure of cartilage has shown high correlation with histology and may be useful for timing surgery. Conclusions: Evaluation of patellofemoral disorders is complex and requires a comprehensive assessment. Recent advancements in imaging have made possible a more precise evaluation of the individual anatomy of the patient, addressing issues of malalignment, instability, and underlying cartilage damage. PMID:23016009

  4. Fabry disease and enzyme replacement therapy in classic patients with same mutation: different formulations--different outcome?

    PubMed

    Politei, J; Schenone, A B; Cabrera, G; Heguilen, R; Szlago, M

    2016-01-01

    We describe the results of the multidisciplinary evaluation in patients with Fabry disease and the same genetic mutation and their outcomes using different approved enzyme replacement therapy (ERT). We measured baseline data and serial results of neuropathic pain assessment and renal, cardiac and cerebrovascular functioning. Pain scale showed improvement in all male cases treated with agalsidasa beta. A mild improvement was detected in agalsidasa alfa-treated patients after 1 year with posterior increase. During the agalsidase beta shortage, two male patients were switched to agalsidasa alfa, after 1 year both cases presented an increase in scale values. Renal evolution showed a tendency toward a decrease in proteinuria in patients using agalsidase beta and worsening with agalsidase alfa. We found improvement in two females using agalsidase beta and no changes in the other cases regarding cardiac functioning. Brain magnetic resonance imaging (MRI) showed increase of white matter lesions in four patients. Improvement and stabilization in neuropathic pain, renal and cardiac functioning and brain MRI were found mainly in patients treated with agalsidase beta. Following the reported recommendations on reintroduction of agalsidase beta after the enzyme shortage, we decided to switch all patients to agalsidase beta. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Tuberculosis of hip: A current concept review

    PubMed Central

    Saraf, Shyam Kumar; Tuli, Surendra Mohan

    2015-01-01

    Tuberculosis (TB) of the hip is second to spine only hence a good number of cases are visiting the medical facilities every year. Many present in the advanced stage of the disease due to delayed diagnosis. In early stages of TB of hip, there is a diagnostic dilemma when plain X-rays are negative. In the present time, diagnostic modalities have improved from the days when diagnosis was based essentially on clinicoradiological presentation alone. By the time definite radiological changes appear on plain X-ray, the disease has moderately advanced. The modern diagnostic facilities like ultrasonography (USG) or magnetic resonance imaging of the hip joint, USG guided aspiration of synovial fluid and obtaining the material for polymerase chain reaction and tissue diagnosis must be utilized. In the treatment, current emphasis is more on mobility with stability at hip. Joint debridement, skeletal traction, and mobilization exercises may give more satisfying results as compared to the immobilization by hip spica. Adults with advanced arthritis and healed infection should be informed and discussed the various treatment modalities including the joint replacement. More and more surgeons are taking up the challenge of putting the total hip replacement in the active stage of the disease. Until the long term results in active disease are well established, we recommend it for the healed disease only in selected cases. PMID:25593352

  6. Tuberculosis of hip: A current concept review.

    PubMed

    Saraf, Shyam Kumar; Tuli, Surendra Mohan

    2015-01-01

    Tuberculosis (TB) of the hip is second to spine only hence a good number of cases are visiting the medical facilities every year. Many present in the advanced stage of the disease due to delayed diagnosis. In early stages of TB of hip, there is a diagnostic dilemma when plain X-rays are negative. In the present time, diagnostic modalities have improved from the days when diagnosis was based essentially on clinicoradiological presentation alone. By the time definite radiological changes appear on plain X-ray, the disease has moderately advanced. The modern diagnostic facilities like ultrasonography (USG) or magnetic resonance imaging of the hip joint, USG guided aspiration of synovial fluid and obtaining the material for polymerase chain reaction and tissue diagnosis must be utilized. In the treatment, current emphasis is more on mobility with stability at hip. Joint debridement, skeletal traction, and mobilization exercises may give more satisfying results as compared to the immobilization by hip spica. Adults with advanced arthritis and healed infection should be informed and discussed the various treatment modalities including the joint replacement. More and more surgeons are taking up the challenge of putting the total hip replacement in the active stage of the disease. Until the long term results in active disease are well established, we recommend it for the healed disease only in selected cases.

  7. Numerical investigation of a tunable band-pass plasmonic filter with a hollow-core ring resonator

    NASA Astrophysics Data System (ADS)

    Setayesh, Amir; Mirnaziry, S. Reza; Sadegh Abrishamian, Mohammad

    2011-03-01

    In this study, a compact nanoscale plasmonic filter which consists of two metal-insulator-metal (MIM) waveguides coupled to each other by a rectangular ring resonator is presented and investigated numerically. The propagating modes of surface plasmon polaritons (SPPs) are studied in this structure. By replacing a portion of the ring core with air, while the outer dimensions of the structure are kept constant, we illustrate the possibility of the redshift of resonant wavelengths in order to tune the resonance modes. This feature is useful for integrated circuits in which we have limitations on the outer dimensions of the filter structure and it is not possible to enlarge the dimension of the ring resonator to reach longer resonant wavelengths. The corresponding results are illustrated by the 2D finite-difference time-domain (FDTD) method. The proposed structure has potential applications in plasmonic integrated circuits and can be simply fabricated.

  8. Identification of Warthin tumor: magnetic resonance imaging versus salivary scintigraphy with technetium-99m pertechnetate.

    PubMed

    Motoori, Ken; Ueda, Takuya; Uchida, Yoshitaka; Chazono, Hideaki; Suzuki, Homare; Ito, Hisao

    2005-01-01

    The aim of this study was to evaluate the accuracy of technetium-99m (Tc-99m) pertechnetate scintigraphy and magnetic resonance (MR) imaging in the diagnosis of Warthin tumor. Sixteen cases of Warthin tumor and 17 cases of non-Warthin tumor were examined by Tc-99m pertechnetate scintigraphy with lemon juice stimulation and MR imaging, including T1-weighted, T2-weighted, short inversion time inversion recovery, diffusion-weighted, and contrast-enhanced dynamic images. We used the receiver operating characteristic (ROC) curve to evaluate diagnostic accuracy. The mean area under the ROC curves of MR imaging in the diagnosis of Warthin tumor (0.97) was higher than that of Tc-99m pertechnetate scintigraphy (0.88). Magnetic resonance imaging is more useful in the evaluation of Warthin tumor than Tc-99m pertechnetate scintigraphy.

  9. Externally calibrated parallel imaging for 3D multispectral imaging near metallic implants using broadband ultrashort echo time imaging.

    PubMed

    Wiens, Curtis N; Artz, Nathan S; Jang, Hyungseok; McMillan, Alan B; Reeder, Scott B

    2017-06-01

    To develop an externally calibrated parallel imaging technique for three-dimensional multispectral imaging (3D-MSI) in the presence of metallic implants. A fast, ultrashort echo time (UTE) calibration acquisition is proposed to enable externally calibrated parallel imaging techniques near metallic implants. The proposed calibration acquisition uses a broadband radiofrequency (RF) pulse to excite the off-resonance induced by the metallic implant, fully phase-encoded imaging to prevent in-plane distortions, and UTE to capture rapidly decaying signal. The performance of the externally calibrated parallel imaging reconstructions was assessed using phantoms and in vivo examples. Phantom and in vivo comparisons to self-calibrated parallel imaging acquisitions show that significant reductions in acquisition times can be achieved using externally calibrated parallel imaging with comparable image quality. Acquisition time reductions are particularly large for fully phase-encoded methods such as spectrally resolved fully phase-encoded three-dimensional (3D) fast spin-echo (SR-FPE), in which scan time reductions of up to 8 min were obtained. A fully phase-encoded acquisition with broadband excitation and UTE enabled externally calibrated parallel imaging for 3D-MSI, eliminating the need for repeated calibration regions at each frequency offset. Significant reductions in acquisition time can be achieved, particularly for fully phase-encoded methods like SR-FPE. Magn Reson Med 77:2303-2309, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Letocart, Vincent, E-mail: vincent.letocart@chu-nantes.fr; Fau, Georges, E-mail: georges.fau@chu-nantes.fr; Tirouvanziam, Ashok, E-mail: ashok.tirouvanziam@chu-nantes.fr

    The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient's clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of themore » stent-graft creating a 'false channel' that compressed the 'true lumen' and induced 'pseudocoarctation' syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.« less

  11. [Invasion of the portal vein by a hydatid cyst. Review of the literature].

    PubMed

    Zubiaurre Lizarralde, Leire; Oyarzabal Pérez, Igor; Ruiz Montesinos, Inmaculada; Guisasola Gorrotxategi, Esther

    2006-01-01

    We have found only 3 publications in the literature that describe portal vein invasion by a hydatid cyst. This complication is very uncommon but should be kept in mind in the diagnosis of anaphylactic shock. Clinical presentation can vary from abdominal pain and fever to portal hypertension or anaphylactic reaction due to leaking of antigenic material from the cyst. Ultrasound and computed tomography scan can identify hydatid cysts and cavernomatosis, but magnetic resonance imaging shows the presence of multiple daughter vesicles replacing the lumen of the portal vein and a communication between the residual cyst and the portal vein. The treatment of choice is surgery, including removal of the cyst and local instillation of scolicide solution. In addition to surgery, administration of albendazole is recommended. Administration should begin 4 days before extirpation and should be continued for more than 4 weeks.

  12. Deferasirox pharmacokinetics evaluation in a woman with hereditary haemochromatosis and heterozygous β-thalassaemia.

    PubMed

    Allegra, Sarah; De Francia, Silvia; Longo, Filomena; Massano, Davide; Cusato, Jessica; Arduino, Arianna; Pirro, Elisa; Piga, Antonio; D'Avolio, Antonio

    2016-12-01

    We present the deferasirox pharmacokinetics evaluation of a female patient on iron chelation, for the interesting findings from her genetic background (hereditary haemochromatosis and heterozygous β-thalassaemia) and clinical history (ileostomy; iron overload from transfusions). Drug plasma concentrations were measured by an HPLC-UV validated method, before and after ileum resection. Area under deferasirox concentration curve over 24h (AUC) values were determined by the mixed log-linear rule, using Kinetica software. AUC was low also with high deferasirox dose as well as tolerability. Non invasive tissue iron quantification by magnetic resonance imaging or superconducting quantum interference device were prevented by a metal hip replacement. Good efficacy and normalisation of iron markers was obtained on long term. Therapeutic drug monitoring in patient in critical conditions may help to understand reasons for non response and set individualised treatment. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC/D): A Systematic Literature Review

    PubMed Central

    Romero, Jorge; Mejia-Lopez, Eliany; Manrique, Carlos; Lucariello, Richard

    2013-01-01

    Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is a genetic form of cardiomyopathy (CM) usually transmitted with an autosomal dominant pattern. It primary affects the right ventricle (RV), but may involve the left ventricle (LV) and culminate in biventricular heart failure (HF), life threatening ventricular arrhythmias and sudden cardiac death (SCD). It accounts for 11%–22% of cases of SCD in the young athlete population. Pathologically is characterized by myocardial atrophy, fibrofatty replacement and chamber dilation. Diagnosis is often difficult due to the nonspecific nature of the disease and the broad spectrum of phenotypic variations. Therefore consensus diagnostic criteria have been developed and combined electrocardiography, echocardiography, cardiac magnetic resonance imaging (CMRI) and myocardial biopsy. Early detection, family screening and risk stratification are the cornerstones in the diagnostic evaluation. Implantable cardioverter-defibrillator (ICD) implantation, ablative procedures and heart transplantation are currently the main therapeutic options. PMID:23761986

  14. Situs ambiguous in a schoolchild

    PubMed Central

    Tortajada, Miguel; Moreno, Miriam; Gracia, Miguel; Sanchis, Amparo

    2010-01-01

    We report the case of a 9-year-old child with asthma, atopic dermatitis and allergic rhinoconjunctivitis due to house dust mites, in whom a routine chest x-ray identified by chance abnormal organ position, such as the stomach located on the right side. Abdominal ultrasonography indicated a centralised liver, with polysplenia on the right side and an inferior cava vein located to the left of the aorta with no interruption. Ultrasonography did not show heart defects. Magnetic resonance imaging (MRI) of the abdomen was performed that showed a short pancreas, with no neck, body and tail in it, and a left inferior vena cava with normal outlet of the renal veins, and absence of the intrahepatic part of the inferior vena cava, that was replaced by the left hemiazygos vein. Spinal cord MRI revealed dorsal syringomelia. In view of the results obtained, the diagnosis of situs ambiguous was established. PMID:22121394

  15. [Panhypopituitarism caused by an intrasellar cystic mass in late-onset hypogonadism clinic].

    PubMed

    Yamamoto, Yoshiyuki; Takada, Shingo; Kinjo, Takanori; Nonomura, Daichi; Yoneda, Suguru; Nomura, Hironori; Tei, Norihide; Matsumiya, Kiyomi; Okusu, Takahiro

    2013-10-01

    A 74-year-old man who was referred to our late onset hypogonadism clinic presented with sweating and loss of appetite. His aging males' symptoms (AMS) and international index of erectile function (IIEF-5) scores were 59 and 2, respectively. His hormonal examination revealed extremely low free testosterone values. The patient was started on androgen replacement therapy, but his symptoms did not improve. Additional hormonal examinations revealed low values for other anterior pituitary hormones. Magnetic resonance imaging revealed an intrasellar cystic mass with suprasellar extension. We considered this mass caused hypothalamic hypopituitarism. A load test for anterior pituitary hormones revealed panhypogonadism. His symptoms improved after administration of adrenal and thyroid hormones and androgen. Five months after start of drug administration, his AMS score improved to 29, but IIEF-5 score showed little change. As a matter of course, not only androgen but all pituitary-related hormones are needed for hypopituitarism patients.

  16. MR-based real time path planning for cardiac operations with transapical access.

    PubMed

    Yeniaras, Erol; Navkar, Nikhil V; Sonmez, Ahmet E; Shah, Dipan J; Deng, Zhigang; Tsekos, Nikolaos V

    2011-01-01

    Minimally invasive surgeries (MIS) have been perpetually evolving due to their potential high impact on improving patient management and overall cost effectiveness. Currently, MIS are further strengthened by the incorporation of magnetic resonance imaging (MRI) for amended visualization and high precision. Motivated by the fact that real-time MRI is emerging as a feasible modality especially for guiding interventions and surgeries in the beating heart; in this paper we introduce a real-time path planning algorithm for intracardiac procedures. Our approach creates a volumetric safety zone inside a beating heart and updates it on-the-fly using real-time MRI during the deployment of a robotic device. In order to prove the concept and assess the feasibility of the introduced method, a realistic operational scenario of transapical aortic valve replacement in a beating heart is chosen as the virtual case study.

  17. Arthroscopic suture bridge technique for intratendinous tear of rotator cuff in chronically painful calcific tendinitis of the shoulder.

    PubMed

    Ji, Jong-Hun; Shafi, Mohamed; Moon, Chang-Yun; Park, Sang-Eun; Kim, Yeon-Jun; Kim, Sung-Eun

    2013-11-01

    Arthroscopic removal, now the main treatment option, has almost replaced open surgery for treatment of resistant calcific tendinitis. In some cases of chronic calcific tendinitis of the shoulder, the calcific materials are hard and adherent to the tendon. Removal of these materials can cause significant intratendinous tears between the superficial and deep layers of the degenerated rotator cuff. Thus far, there are no established surgical techniques for removing the calcific materials while ensuring cuff integrity. Good clinical results for rotator cuff repair were achieved by using an arthroscopic suture bridge technique in patients with long-standing calcific tendinitis. Intact rotator cuff integrity and recovery of signal change on follow-up magnetic resonance imaging scans were confirmed. This is a technical note about a surgical technique and its clinical results with a review of relevant published reports. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  18. Reward Prediction Errors in Drug Addiction and Parkinson's Disease: from Neurophysiology to Neuroimaging.

    PubMed

    García-García, Isabel; Zeighami, Yashar; Dagher, Alain

    2017-06-01

    Surprises are important sources of learning. Cognitive scientists often refer to surprises as "reward prediction errors," a parameter that captures discrepancies between expectations and actual outcomes. Here, we integrate neurophysiological and functional magnetic resonance imaging (fMRI) results addressing the processing of reward prediction errors and how they might be altered in drug addiction and Parkinson's disease. By increasing phasic dopamine responses, drugs might accentuate prediction error signals, causing increases in fMRI activity in mesolimbic areas in response to drugs. Chronic substance dependence, by contrast, has been linked with compromised dopaminergic function, which might be associated with blunted fMRI responses to pleasant non-drug stimuli in mesocorticolimbic areas. In Parkinson's disease, dopamine replacement therapies seem to induce impairments in learning from negative outcomes. The present review provides a holistic overview of reward prediction errors across different pathologies and might inform future clinical strategies targeting impulsive/compulsive disorders.

  19. Diagnostic significance of gadolinium-DTPA (diethylenetriamine penta-acetic acid) enhanced magnetic resonance imaging in thrombolytic treatment for acute myocardial infarction: its potential in assessing reperfusion.

    PubMed Central

    van der Wall, E E; van Dijkman, P R; de Roos, A; Doornbos, J; van der Laarse, A; Manger Cats, V; van Voorthuisen, A E; Matheijssen, N A; Bruschke, A V

    1990-01-01

    The diagnostic value of gadolinium-DTPA (diethylenetriamine penta-acetic acid) enhanced magnetic resonance imaging in patients treated by thrombolysis for acute myocardial infarction was assessed in 27 consecutive patients who had a first acute myocardial infarction (14 anterior, 13 inferior) and who underwent thrombolytic treatment and coronary arteriography within 4 hours of the onset of symptoms. Magnetic resonance imaging was performed 93 hours (range 15-241) after the onset of symptoms. A Philips Gyroscan (0.5 T) was used, and spin echo measurements (echo time 30 ms) were made before and 20 minutes after intravenous injection of 0.1 mmol/kg gadolinium-DTPA. In all patients contrast enhancement of the infarcted areas was seen after Gd-DTPA. The signal intensities of the infarcted and normal values were used to calculate the intensity ratios. Mean (SD) intensity ratios after Gd-DTPA were significantly increased (1.15 (0.17) v 1.52 (0.29). Intensity ratios were higher in the 17 patients who underwent magnetic resonance imaging more than 72 hours after the onset of symptoms than in the 10 who underwent magnetic resonance imaging earlier, the difference being significantly greater after administration of Gd-DTPA (1.38 (0.12) v 1.61 (0.34). When patients were classified according to the site and size of the infarcted areas, or to reperfusion (n = 19) versus non-reperfusion (n = 8), the intensity ratios both before and after Gd-DTPA did not show significant differences. Magnetic resonance imaging with Gd-DTPA improved the identification of acutely infarcted areas, but with current techniques did not identify patients in whom thrombolytic treatment was successful. Images PMID:2310640

  20. Patterns of magnetic resonance imaging abnormalities in symptomatic patients with Krabbe disease correspond to phenotype.

    PubMed

    Abdelhalim, Ahmed N; Alberico, Ronald A; Barczykowski, Amy L; Duffner, Patricia K

    2014-02-01

    Initial magnetic resonance imaging studies of individuals with Krabbe disease were analyzed to determine whether the pattern of abnormalities corresponded to the phenotype. This was a retrospective, nonblinded study. Families/patients diagnosed with Krabbe disease submitted medical records and magnetic resonance imaging discs for central review. Institutional review board approval/informed consents were obtained. Sixty-four magnetic resonance imaging scans were reviewed by two neuroradiologists and a child neurologist according to phenotype: early infantile (onset 0-6 months) = 39 patients; late infantile (onset 7-12 months) = 10 patients; later onset (onset 13 months-10 years) = 11 patients; adolescent (onset 11-20 years) = one patient; and adult (21 years or greater) = three patients. Local interpretations were compared with central review. Magnetic resonance imaging abnormalities differed among phenotypes. Early infantile patients had a predominance of increased intensity in the dentate/cerebellar white matter as well as changes in the deep cerebral white matter. Later onset patients did not demonstrate involvement in the dentate/cerebellar white matter but had extensive involvement of the deep cerebral white matter, parieto-occipital region, and posterior corpus callosum. Late infantile patients exhibited a mixed pattern; 40% had dentate/cerebellar white matter involvement while all had involvement of the deep cerebral white matter. Adolescent/adult patients demonstrated isolated corticospinal tract involvement. Local and central reviews primarily differed in interpretation of the early infantile phenotype. Analysis of magnetic resonance imaging in a large cohort of symptomatic patients with Krabbe disease demonstrated imaging abnormalities correspond to specific phenotypes. Knowledge of these patterns along with typical clinical signs/symptoms should promote earlier diagnosis and facilitate treatment. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Noninvasive Imaging of Early Venous Thrombosis by 19F Magnetic Resonance Imaging With Targeted Perfluorocarbon Nanoemulsions.

    PubMed

    Temme, Sebastian; Grapentin, Christoph; Quast, Christine; Jacoby, Christoph; Grandoch, Maria; Ding, Zhaoping; Owenier, Christoph; Mayenfels, Friederike; Fischer, Jens W; Schubert, Rolf; Schrader, Jürgen; Flögel, Ulrich

    2015-04-21

    Noninvasive detection of deep venous thrombi and subsequent pulmonary thromboembolism is a serious medical challenge, since both incidences are difficult to identify by conventional ultrasound techniques. Here, we report a novel technique for the sensitive and specific identification of developing thrombi using background-free 19F magnetic resonance imaging, together with α2-antiplasmin peptide (α2AP)-targeted perfluorocarbon nanoemulsions (PFCs) as contrast agent, which is cross-linked to fibrin by active factor XIII. Ligand functionality was ensured by mild coupling conditions using the sterol-based postinsertion technique. Developing thrombi with a diameter<0.8 mm could be visualized unequivocally in the murine inferior vena cava as hot spots in vivo by simultaneous acquisition of anatomic matching 1H and 19F magnetic resonance images at 9.4 T with both excellent signal-to-noise and contrast-to-noise ratios (71±22 and 17±5, respectively). Furthermore, α2AP-PFCs could be successfully applied for the diagnosis of experimentally induced pulmonary thromboembolism. In line with the reported half-life of factor XIIIa, application of α2AP-PFCs>60 minutes after thrombus induction no longer resulted in detectable 19F magnetic resonance imaging signals. Corresponding results were obtained in ex vivo generated human clots. Thus, α2AP-PFCs can visualize freshly developed thrombi that might still be susceptible to pharmacological intervention. Our results demonstrate that 1H/19F magnetic resonance imaging, together with α2AP-PFCs, is a sensitive, noninvasive technique for the diagnosis of acute deep venous thrombi and pulmonary thromboemboli. Furthermore, ligand coupling by the sterol-based postinsertion technique represents a unique platform for the specific targeting of PFCs for in vivo 19F magnetic resonance imaging. © 2015 American Heart Association, Inc.

  2. Anatomical Brain Magnetic Resonance Imaging of Typically Developing Children and Adolescents

    ERIC Educational Resources Information Center

    Giedd, Jay N.; Lalonde, Francois M.; Celano, Mark J.; White, Samantha L.; Wallace, Gregory L.; Lee, Nancy R.; Lenroot, Rhoshel K.

    2009-01-01

    Methodological issues relevant to magnetic resonance imaging studies of brain anatomy are discussed along with the findings on the neuroanatomic changes during childhood and adolescence. The development of the brain is also discussed.

  3. Dissociations between behavioural and functional magnetic resonance imaging-based evaluations of cognitive function after brain injury

    PubMed Central

    Bardin, Jonathan C.; Fins, Joseph J.; Katz, Douglas I.; Hersh, Jennifer; Heier, Linda A.; Tabelow, Karsten; Dyke, Jonathan P.; Ballon, Douglas J.; Schiff, Nicholas D.

    2011-01-01

    Functional neuroimaging methods hold promise for the identification of cognitive function and communication capacity in some severely brain-injured patients who may not retain sufficient motor function to demonstrate their abilities. We studied seven severely brain-injured patients and a control group of 14 subjects using a novel hierarchical functional magnetic resonance imaging assessment utilizing mental imagery responses. Whereas the control group showed consistent and accurate (for communication) blood-oxygen-level-dependent responses without exception, the brain-injured subjects showed a wide variation in the correlation of blood-oxygen-level-dependent responses and overt behavioural responses. Specifically, the brain-injured subjects dissociated bedside and functional magnetic resonance imaging-based command following and communication capabilities. These observations reveal significant challenges in developing validated functional magnetic resonance imaging-based methods for clinical use and raise interesting questions about underlying brain function assayed using these methods in brain-injured subjects. PMID:21354974

  4. Optical Pumping Spin Exchange 3He Gas Cells for Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Kim, W.; Stepanyan, S. S.; Kim, A.; Jung, Y.; Woo, S.; Yurov, M.; Jang, J.

    2009-08-01

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the 3He-N2 mixture. The cells could be refilled. The 3He reaches around 50% polarization in 5-15 hours.

  5. Whole-body MRI in pediatric patients with cancer.

    PubMed

    Guimarães, Marcos Duarte; Noschang, Julia; Teixeira, Sara Reis; Santos, Marcel Koenigkam; Lederman, Henrique Manoel; Tostes, Vivian; Kundra, Vikas; Oliveira, Alex Dias; Hochhegger, Bruno; Marchiori, Edson

    2017-02-10

    Cancer is the leading cause of natural death in the pediatric populations of developed countries, yet cure rates are greater than 70% when a cancer is diagnosed in its early stages. Recent advances in magnetic resonance imaging methods have markedly improved diagnostic and therapeutic approaches, while avoiding the risks of ionizing radiation that are associated with most conventional radiological methods, such as computed tomography and positron emission tomography/computed tomography. The advent of whole-body magnetic resonance imaging in association with the development of metabolic- and function-based techniques has led to the use of whole-body magnetic resonance imaging for the screening, diagnosis, staging, response assessment, and post-therapeutic follow-up of children with solid sporadic tumours or those with related genetic syndromes. Here, the advantages, techniques, indications, and limitations of whole-body magnetic resonance imaging in the management of pediatric oncology patients are presented.

  6. Intraventricular mass lesions at magnetic resonance imaging: iconographic essay - part 1*

    PubMed Central

    de Castro, Felipe Damásio; Reis, Fabiano; Guerra, José Guilherme Giocondo

    2014-01-01

    The present essay is illustrated with magnetic resonance images obtained at the authors' institution over the past 15 years and discusses the main imaging findings of intraventricular tumor-like lesions (ependymoma, pilocytic astrocytoma, central neurocytoma, ganglioglioma, choroid plexus papilloma, primitive neuroectodermal tumors, meningioma, epidermoid tumor). Such lesions represent a subgroup of intracranial lesions with unique characteristics and some image patterns that may facilitate the differential diagnosis. PMID:25741075

  7. Autism Spectrum Disorder: Does Neuroimaging Support the DSM-5 Proposal for a Symptom Dyad? A Systematic Review of Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging Studies

    ERIC Educational Resources Information Center

    Pina-Camacho, Laura; Villero, Sonia; Fraguas, David; Boada, Leticia; Janssen, Joost; Navas-Sanchez, Francisco J.; Mayoral, Maria; Llorente, Cloe; Arango, Celso; Parellada, Mara

    2012-01-01

    A systematic review of 208 studies comprising functional magnetic resonance imaging and diffusion tensor imaging data in patients with "autism spectrum disorder" (ASD) was conducted, in order to determine whether these data support the forthcoming DSM-5 proposal of a social communication and behavioral symptom dyad. Studies consistently reported…

  8. Brain lesions in septic shock: a magnetic resonance imaging study.

    PubMed

    Sharshar, Tarek; Carlier, Robert; Bernard, Francis; Guidoux, Céline; Brouland, Jean-Philippe; Nardi, Olivier; de la Grandmaison, Geoffroy Lorin; Aboab, Jérôme; Gray, Françoise; Menon, David; Annane, Djillali

    2007-05-01

    Understanding of sepsis-induced brain dysfunction remains poor, and relies mainly on data from animals or post-mortem studies in patients. The current study provided findings from magnetic resonance imaging of the brain in septic shock. Nine patients with septic shock and brain dysfunction [7 women, median age 63 years (interquartile range 61-79 years), SAPS II: 48 (44-56), SOFA: 8 (6-10)] underwent brain magnetic resonance imaging including gradient echo T1-weighted, fluid-attenuated inversion recovery (FLAIR), T2-weighted and diffusion isotropic images, and mapping of apparent diffusion coefficient. Brain imaging was normal in two patients, showed multiple ischaemic strokes in two patients, and in the remaining patients showed white matter lesions at the level of the centrum semiovale, predominating around Virchow-Robin spaces, ranging from small multiple areas to diffuse lesions, and characterised by hyperintensity on FLAIR images. The main lesions were also characterised by reduced signal on diffusion isotropic images and increased apparent diffusion coefficient. The lesions of the white matter worsened with increasing duration of shock and were correlated with Glasgow Outcome Score. This preliminary study showed that sepsis-induced brain lesions can be documented by magnetic resonance imaging. These lesions predominated in the white matter, suggesting increased blood-brain barrier permeability, and were associated with poor outcome.

  9. Magnetic resonance imaging of semicircular canals.

    PubMed Central

    Sbarbati, A; Leclercq, F; Zancanaro, C; Antonakis, K

    1992-01-01

    The present paper reports the results of the first investigation of the semicircular canals in a living, small animal by means of high spatial resolution magnetic resonance imaging. This procedure is noninvasive and allows identification of the endolymphatic and perilymphatic spaces yielding a morphology quite consistent with direct anatomical examination. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:1506290

  10. Magnetic Resonance Imaging Assessment of the Velopharyngeal Mechanism at Rest and during Speech in Chinese Adults and Children

    ERIC Educational Resources Information Center

    Tian, Wei; Yin, Heng; Redett, Richard J.; Shi, Bing; Shi, Jin; Zhang, Rui; Zheng, Qian

    2010-01-01

    Purpose: Recent applications of the magnetic resonance imaging (MRI) technique introduced accurate 3-dimensional measurements of the velopharyngeal mechanism. Further standardization of the data acquisition and analysis protocol was successfully applied to imaging adults at rest and during phonation. This study was designed to test and modify a…

  11. Sprectroscopic and time-resolved optical methods and apparatus for imaging objects in turbed media

    NASA Technical Reports Server (NTRS)

    Alfano, Robert R. (Inventor); Zevallos, Manuel E. (Inventor); Gayen, Swapan Kumar (Inventor)

    2003-01-01

    Method and apparatus for imaging objects in turbid media. In one embodiment, the method comprises illuminating at least a portion of the turbid medium with substantially monochromatic light of at least two wavelengths in the 600-1500 nm spectral range. A first of the at least two wavelengths is equal to a resonance wavelength for an optical property of an object in the illuminated portion of the turbid medium but is not equal to a resonance wavelength for the turbid medium. A second of the at least two wavelengths is not equal to a resonance wavelength for either the object or the turbid medium. Light emergent from the turbid medium following each of the foregoing illuminations comprises a ballistic component, a snake component and a diffuse component. A direct shadowgram image may be obtained by preferentially passing from the emergent light, following each illumination. the ballistic and snake components thereof and detecting the preferentially passed light. Alternatively, an inverse reconstruction image may be obtained by determining, following each illumination, the intensity of the diffuse component at a plurality of points in time and then using these pluralities of intensity determinations and a mathematical inversion algorithm to form an image of the object in the turbid medium. An image of the object with higher contrast and better quality may be obtained by using the ratio or difference of the images recorded with resonant light and non-resonant light.

  12. Use of three-dimensional time-resolved phase-contrast magnetic resonance imaging with vastly undersampled isotropic projection reconstruction to assess renal blood flow in a renal cell carcinoma patient treated with sunitinib: a case report.

    PubMed

    Takayama, Tatsuya; Takehara, Yasuo; Sugiyama, Masataka; Sugiyama, Takayuki; Ishii, Yasuo; Johnson, Kevin E; Wieben, Oliver; Wakayama, Tetsuya; Sakahara, Harumi; Ozono, Seiichiro

    2014-08-14

    New imaging modalities to assess the efficacy of drugs that have molecular targets remain under development. Here, we describe for the first time the use of time-resolved three-dimensional phase-contrast magnetic resonance imaging to monitor changes in blood supply to a tumor during sunitinib treatment in a patient with localized renal cell carcinoma. A 43-year-old Japanese woman with a tumor-bearing but functional single kidney presented at our hospital in July 2012. Computed tomography and magnetic resonance imaging revealed a cT1aN0M0 renal cell carcinoma embedded in the upper central region of the left kidney. She was prescribed sunitinib as neoadjuvant therapy for 8 months, and then underwent partial nephrectomy. Tumor monitoring during this time was done using time-resolved three-dimensional phase-contrast magnetic resonance imaging, a recent technique which specifically measures blood flow in the various vessels of the kidney. This imaging allowed visualization of the redistribution of renal blood flow during treatment, and showed that flow to the tumor was decreased and flows to other areas increased. Of note, this change occurred in the absence of any change in tumor size. The ability of time-resolved three-dimensional phase-contrast magnetic resonance imaging to provide quantitative information on blood supply to tumors may be useful in monitoring the efficacy of sunitinib treatment.

  13. Measurement of left ventricular mass in vivo using gated nuclear magnetic resonance imaging.

    PubMed

    Florentine, M S; Grosskreutz, C L; Chang, W; Hartnett, J A; Dunn, V D; Ehrhardt, J C; Fleagle, S R; Collins, S M; Marcus, M L; Skorton, D J

    1986-07-01

    Alterations of left ventricular mass occur in a variety of congenital and acquired heart diseases. In vivo determination of left ventricular mass, using several different techniques, has been previously reported. Problems inherent in some previous methods include the use of ionizing radiation, complicated geometric assumptions and invasive techniques. We tested the ability of gated nuclear magnetic resonance imaging to determine in vivo left ventricular mass in animals. By studying both dogs (n = 9) and cats (n = 2) of various sizes, a broad range of left ventricular mass (7 to 133 g) was examined. With a 0.5 tesla superconducting nuclear magnetic resonance imaging system the left ventricle was imaged in the transaxial plane and multiple adjacent 10 mm thick slices were obtained. Endocardial and epicardial edges were manually traced in each computer-displayed image. The wall area of each image was determined by computer and the areas were summed and multiplied by the slice thickness and the specific gravity of muscle, providing calculated left ventricular mass. Calculated left ventricular mass was compared with actual postmortem left ventricular mass using linear regression analysis. An excellent relation between calculated and actual mass was found (r = 0.95; SEE = 13.1 g; regression equation: magnetic resonance mass = 0.95 X actual mass + 14.8 g). Intraobserver and interobserver reproducibility were also excellent (r = 0.99). Thus, gated nuclear magnetic resonance imaging can accurately determine in vivo left ventricular mass in anesthetized animals.

  14. Time-dependent change of blood flow in the prostate treated with high-intensity focused ultrasound.

    PubMed

    Shoji, Sunao; Tonooka, Akiko; Hashimoto, Akio; Nakamoto, Masahiko; Tomonaga, Tetsuro; Nakano, Mayura; Sato, Haruhiro; Terachi, Toshiro; Koike, Junki; Uchida, Toyoaki

    2014-09-01

    Avascular areas on contrast-enhanced magnetic resonance imaging have been considered to be areas of localized prostate cancer successfully treated by high-intensity focused ultrasound. However, the optimal timing of magnetic resonance imaging has not been discussed. The thermal effect of high-intensity focused ultrasound is degraded by regional prostatic blood flow. Conversely, the mechanical effect of high-intensity focused ultrasound (cavitation) is not affected by blood flow, and can induce vessel damage. In this series, the longitudinal change of blood flow on contrast-enhanced magnetic resonance imaging was observed from postoperative day 1 to postoperative day 14 in 10 patients treated with high-intensity focused ultrasound. The median rates of increase in the non-enhanced volume of the whole gland, transition zone and peripheral zone from postoperative day 1 to postoperative day 14 were 36%, 39%, and 34%, respectively. In another pathological analysis of the prostate tissue of 17 patients immediately after high-intensity focused ultrasound without neoadjuvant hormonal therapy, we observed diffuse coagulative degeneration and partial non-coagulative prostate tissue around arteries with vascular endothelial cell detachment. These observations on contrast-enhanced magnetic resonance imaging support a time-dependent change of the blood flow in the prostate treated with high-intensity focused ultrasound. Additionally, our pathological findings support the longitudinal changes of these magnetic resonance imaging findings. Further large-scale studies will investigate the most appropriate timing of contrast-enhanced magnetic resonance imaging for evaluation of the effectiveness of high-intensity focused ultrasound for localized prostate cancer. © 2014 The Japanese Urological Association.

  15. Polymer-Based Reconstruction of the Inferior Vena Cava in Rat: Stem Cells or RGD Peptide?

    PubMed Central

    Pontailler, Margaux; Illangakoon, Eranka; Williams, Gareth R.; Marijon, Camille; Bellamy, Valérie; Balvay, Daniel; Autret, Gwenhael; Vanneaux, Valérie; Larghero, Jérôme; Planat-Benard, Valérie; Perier, Marie-Cécile; Bruneval, Patrick; Menasché, Philippe

    2015-01-01

    As part of a program targeted at developing a resorbable valved tube for replacement of the right ventricular outflow tract, we compared three biopolymers (polyurethane [PU], polyhydroxyalkanoate (the poly(3-hydroxybutyrate-co-3-hydroxyvalerate-co-4-hydroxyvalerate) [PHBVV]), and polydioxanone [PDO]) and two biofunctionalization techniques (using adipose-derived stem cells [ADSCs] or the arginine-glycine-aspartate [RGD] peptide) in a rat model of partial inferior vena cava (IVC) replacement. Fifty-three Wistar rats first underwent partial replacement of the IVC with an acellular electrospun PDO, PU, or PHBVV patch, and 31 nude rats subsequently underwent the same procedure using a PDO patch biofunctionalized either by ADSC or RGD. Results were assessed both in vitro (proliferation and survival of ADSC seeded onto the different materials) and in vivo by magnetic resonance imaging (MRI), histology, immunohistochemistry [against markers of vascular cells (von Willebrand factor [vWF], smooth muscle actin [SMA]), and macrophages ([ED1 and ED2] immunostaining)], and enzyme-linked immunosorbent assay (ELISA; for the expression of various cytokines and inducible NO synthase). PDO showed the best in vitro properties. Six weeks after implantation, MRI did not detect significant luminal changes in any group. All biopolymers were evenly lined by vWF-positive cells, but only PDO and PHBVV showed a continuous layer of SMA-positive cells at 3 months. PU patches resulted in a marked granulomatous inflammatory reaction. The ADSC and RGD biofunctionalization yielded similar outcomes. These data confirm the good biocompatibility of PDO and support the concept that appropriately peptide-functionalized polymers may be successfully substituted for cell-loaded materials. PMID:25611092

  16. Editorial Commentary: Put Down Your Saw and Pick Up Your Scope! Or, Why Burn Down the Bridge When the Road Ahead Is Full of Potholes? Reverse Total Shoulder Replacement Versus Arthroscopic Rotator Cuff Repair.

    PubMed

    Tauro, Joseph C

    2018-04-01

    Are we doing too many reverse total shoulder replacements and not fixing enough repairable rotator cuff tears? A convincing argument can be made for attempting to repair most, not all, very large rotator cuff tears in patients who do not have a significant arthritic change in the shoulder. My experience over more than 25 years of arthroscopic rotator cuff repair (ARCR) is that the only good way to know if it is repairable is to try. But some patients really do not pass my "eyeball test" as to whether they can rehabilitate and heal enough to make an ARCR reasonable. Magnetic resonance imaging scans are useful, mostly to help me with tear pattern recognition, how much time and skill I might need for the repair, and to help me council my patients as to their ultimate functional recovery. I have had surprises both ways: some ARCRs that I thought would be easy turned out to be very challenging and others that I thought would be "mission impossible" turned out to be "mission accomplished"! The rationale for jumping ahead primarily to reverse total shoulder replacements reminds me of certain tax cut plans I have heard talk of lately. Sounds great now (well, maybe the complication rate is a little high) but there might be a price to pay down the road. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Magnetic Resonance Imaging to Visualize Disintegration of Oral Formulations.

    PubMed

    Curley, Louise; Hinton, Jordan; Marjoribanks, Cameron; Mirjalili, Ali; Kennedy, Julia; Svirskis, Darren

    2017-03-01

    This article demonstrates that magnetic resonance imaging can visualize the disintegration of a variety of paracetamol containing oral formulations in an in vitro setting and in vivo in the human stomach. The different formulations had unique disintegration profiles which could be imaged both in vitro and in vivo. No special formulation approaches or other contrast agents were required. These data demonstrate the potential for further use of magnetic resonance imaging to investigate and understand the disintegration behavior of different formulation types in vivo, and could potentially be used as a teaching tool in pharmaceutical and medical curricula. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  18. A simple acquisition strategy to avoid off-resonance blurring in spiral imaging with redundant spiral-in/out k-space trajectories

    PubMed Central

    Fielden, Samuel W.; Meyer, Craig H.

    2014-01-01

    Purpose The major hurdle to widespread adoption of spiral trajectories has been their poor off-resonance performance. Here we present a self-correcting spiral k-space trajectory that avoids much of the well-known spiral blurring during data acquisition. Theory and Methods In comparison with a traditional spiral-out trajectory, the spiral-in/out trajectory has improved off-resonance performance. By combining two spiral-in/out acquisitions, one rotated 180° in k-space compared to the other, multi-shot spiral-in/out artifacts are eliminated. A phantom was scanned with the center frequency manually tuned 20, 40, 80, and 160 Hz off-resonance with both a spiral-out gradient echo sequence and the redundant spiral-in/out sequence. The phantom was also imaged in an oblique orientation in order to demonstrate improved concomitant gradient field performance of the sequence, and was additionally incorporated into a spiral turbo spin echo sequence for brain imaging. Results Phantom studies with manually-tuned off-resonance agree well with theoretical calculations, showing that moderate off-resonance is well-corrected by this acquisition scheme. Blur due to concomitant fields is reduced, and good results are obtained in vivo. Conclusion The redundant spiral-in/out trajectory results in less image blur for a given readout length than a traditional spiral-out scan, reducing the need for complex off-resonance correction algorithms. PMID:24604539

  19. A simple acquisition strategy to avoid off-resonance blurring in spiral imaging with redundant spiral-in/out k-space trajectories.

    PubMed

    Fielden, Samuel W; Meyer, Craig H

    2015-02-01

    The major hurdle to widespread adoption of spiral trajectories has been their poor off-resonance performance. Here we present a self-correcting spiral k-space trajectory that avoids much of the well-known spiral blurring during data acquisition. In comparison with a traditional spiral-out trajectory, the spiral-in/out trajectory has improved off-resonance performance. By combining two spiral-in/out acquisitions, one rotated 180° in k-space compared with the other, multishot spiral-in/out artifacts are eliminated. A phantom was scanned with the center frequency manually tuned 20, 40, 80, and 160 Hz off-resonance with both a spiral-out gradient echo sequence and the redundant spiral-in/out sequence. The phantom was also imaged in an oblique orientation in order to demonstrate improved concomitant gradient field performance of the sequence. Additionally, the trajectory was incorporated into a spiral turbo spin echo sequence for brain imaging. Phantom studies with manually tuned off-resonance agree well with theoretical calculations, showing that moderate off-resonance is well-corrected by this acquisition scheme. Blur due to concomitant fields is reduced, and good results are obtained in vivo. The redundant spiral-in/out trajectory results in less image blur for a given readout length than a traditional spiral-out scan, reducing the need for complex off-resonance correction algorithms. © 2014 Wiley Periodicals, Inc.

  20. Mastracchio during EMU FPS Remove and Replace OPS

    NASA Image and Video Library

    2014-04-14

    Expedition 39 flight engineer Rick Mastracchio poses for a photo with the replacement Fan Pump Separator (FPS) and Extravehicular Mobility Unit (EMU) 3005. Image was taken in the Quest Airlock (A/L) during FPS remove and replace operations.

Top