Label-free optical biosensing with slot-waveguides.
Barrios, Carlos A; Bañuls, María José; González-Pedro, Victoria; Gylfason, Kristinn B; Sánchez, Benito; Griol, Amadeu; Maquieira, A; Sohlström, H; Holgado, M; Casquel, R
2008-04-01
We demonstrate label-free molecule detection by using an integrated biosensor based on a Si(3)N(4)/SiO(2) slot-waveguide microring resonator. Bovine serum albumin (BSA) and anti-BSA molecular binding events on the sensor surface are monitored through the measurement of resonant wavelength shifts with varying biomolecule concentrations. The biosensor exhibited sensitivities of 1.8 and 3.2 nm/(ng/mm(2)) for the detection of anti-BSA and BSA, respectively. The estimated detection limits are 28 and 16 pg/mm(2) for anti-BSA and BSA, respectively, limited by wavelength resolution.
Specific determination of bromate in bread by ion chromatography with ICP-MS.
Akiyama, Takumi; Yamanaka, Michiko; Date, Yukiko; Kubota, Hiroki; Nagaoka, Megumi Hamano; Kawasaki, Yoko; Yamazaki, Takeshi; Yomota, Chikako; Maitani, Tamio
2002-12-01
A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g.
NASA Astrophysics Data System (ADS)
Jiang, Jingjing; Du, Xuezhong
2014-09-01
Sensitive electrochemical sensors were fabricated with reduced graphene oxide-supported Au@Pd (Au@Pd-RGO) nanocomposites by one-step synthesis for individual and simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) with low detection limits and wide concentration ranges. From the Au@Pd-RGO-modified electrodes, well-separated oxidation peaks and enhanced peak currents of AA, DA, and UA were observed owing to the superior conductivity of RGO and the excellent catalytic activity of Au@Pd nanoparticles. For individual detection, the linear responses of AA, DA, and UA were in the concentration ranges of 0.1-1000, 0.01-100, and 0.02-500 μM with detection limits of 0.02, 0.002, and 0.005 μM (S/N = 3), respectively. For simultaneous detection by synchronous change of the concentrations of AA, DA, and UA, the linear response ranges were 1-800, 0.1-100, and 0.1-350 μM with detection limits of 0.28, 0.024, and 0.02 μM (S/N = 3), respectively. The fabricated sensors were further applied to the detection of AA, DA, and UA in urine samples. The Au@Pd-RGO nanocomposites have promising applications in highly sensitive and selective electrochemical sensing.Sensitive electrochemical sensors were fabricated with reduced graphene oxide-supported Au@Pd (Au@Pd-RGO) nanocomposites by one-step synthesis for individual and simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) with low detection limits and wide concentration ranges. From the Au@Pd-RGO-modified electrodes, well-separated oxidation peaks and enhanced peak currents of AA, DA, and UA were observed owing to the superior conductivity of RGO and the excellent catalytic activity of Au@Pd nanoparticles. For individual detection, the linear responses of AA, DA, and UA were in the concentration ranges of 0.1-1000, 0.01-100, and 0.02-500 μM with detection limits of 0.02, 0.002, and 0.005 μM (S/N = 3), respectively. For simultaneous detection by synchronous change of the concentrations of AA, DA, and UA, the linear response ranges were 1-800, 0.1-100, and 0.1-350 μM with detection limits of 0.28, 0.024, and 0.02 μM (S/N = 3), respectively. The fabricated sensors were further applied to the detection of AA, DA, and UA in urine samples. The Au@Pd-RGO nanocomposites have promising applications in highly sensitive and selective electrochemical sensing. Electronic supplementary information (ESI) available: pH optimization, comparison of sensor performances, interference experiments, and detection in urine samples. See DOI: 10.1039/c4nr01774a
NASA Astrophysics Data System (ADS)
Salem, A. A.; Barsoum, B. N.; Izake, E. L.
2004-03-01
New spectrophotometric and fluorimetric methods have been developed to determine diazepam, bromazepam and clonazepam (1,4-benzodiazepines) in pure forms, pharmaceutical preparations and biological fluid. The new methods are based on measuring absorption or emission spectra in methanolic potassium hydroxide solution. Fluorimetric methods have proved selective with low detection limits, whereas photometric methods showed relatively high detection limits. Successive applications of developed methods for drugs determination in pharmaceutical preparations and urine samples were performed. Photometric methods gave linear calibration graphs in the ranges of 2.85-28.5, 0.316-3.16, and 0.316-3.16 μg ml -1 with detection limits of 1.27, 0.08 and 0.13 μg ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 2.60, 5.26 and 3.93 and relative standard deviations (R.S.D.s) of 2.79, 2.12 and 2.83, respectively, were obtained. Fluorimetric methods gave linear calibration graphs in the ranges of 0.03-0.34, 0.03-0.32 and 0.03-0.38 μg ml -1 with detection limits of 7.13, 5.67 and 16.47 ng ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 0.29, 4.33 and 5.42 and R.S.D.s of 1.27, 1.96 and 1.14 were obtained, respectively. Statistical Students t-test and F-test have been used and satisfactory results were obtained.
Altiokka, G; Atkosar, Z; Can, N O
2002-10-15
A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively. Copyright 2002 Elsevier Science B.V.
Ultrasensitive Detection of Shigella Species in Blood and Stool.
Luo, Jieling; Wang, Jiapeng; Mathew, Anup S; Yau, Siu-Tung
2016-02-16
A modified immunosensing system with voltage-controlled signal amplification was used to detect Shigella in stool and blood matrixes at the single-digit CFU level. Inactivated Shigella was spiked in these matrixes and detected directly. The detection was completed in 78 min. Detection limits of 21 CFU/mL and 18 CFU/mL were achieved in stool and blood, respectively, corresponding to 2-7 CFUs immobilized on the detecting electrode. The outcome of the detection of extremely low bacterium concentration, i.e., below 100 CFU/mL, blood samples show a random nature. An analysis of the detection probabilities indicates the correlation between the sample volume and the success of detection and suggests that sample volume is critical for ultrasensitive detection of bacteria. The calculated detection limit is qualitatively in agreement with the empirically determined detection limit. The demonstrated ultrasensitive detection of Shigella on the single-digit CFU level suggests the feasibility of the direct detection of the bacterium in the samples without performing a culture.
Fantuzzi, G; Aggazzotti, G; Righi, E; Predieri, G; Giacobazzi, P; Kanitz, S; Barbone, F; Sansebastiano, G; Ricci, C; Leoni, V; Fabiani, L; Triassi, M
2007-01-01
This study investigated the exposure to organohalogens compounds in drinking water from 9 Italian towns (Udine, Genova, Parma, Modena, Siena, Roma, L'Aquila, Napoli and Catania). Overall, 1199 samples collected from 72 waterworks were analyzed. THMs, trichloroethylene and tetrachloroethylene were evaluated using the head-space gas chromatographic technique (detection limit of 0.01 microg/l; chlorite and chlorate analysis was performed by ion chromatography (detection limit of 20 microg/l). THMs were evidenced in 925 samples (77%) (median value: 1.12 micro/l; range: 0.01-54 mciro/l) and 7 were higher than the THMs Italian limit of 30 microg/l. Chlorite and chlorate levels were higher than the detection limit in 45% for chlorite and in 34% for chlorate samples; median values were 221 microg/l and 76 microg/l, respectively. Chlorite values were higher than the chlorite Italian limit (700 microg/l) in 35 samples (8.7%). Trichloroethylene and tetrachloroethylene were measured in 29% and 44% of the investigated samples and showed values lower than the Italian limit (highest levels of 6 microg/l and 9 microg/l, respectively). The low levels detected of THMs, trichloroethylene and tetrachloroethylene have no potentials effects on human health, whereas, the levels of chlorite and chlorates should be further evaluated and their potential effects for the populations using these drinking waters, better understood.
Dual fluorescence/contactless conductivity detection for microfluidic chip.
Liu, Cui; Mo, Yun-yan; Chen, Zuan-guang; Li, Xiang; Li, Ou-lian; Zhou, Xie
2008-07-28
A new dual detection system for microchip is reported. Both fluorescence detector (FD) and contactless conductivity detector (CCD) were combined together and integrated on a microfluidic chip. They shared a common detection position and responded simultaneously. A blue light-emitting diode was used as excitation source and a small planar photodiode was used to collect the emitted fluorescence in fluorescence detection, which made the device more compact and portable. The coupling of the fluorescence and contactless conductivity modes at the same position of a single separation channel enhanced the detection characterization of sample and offered simultaneous detection information of both fluorescent and charged specimen. The detection conditions of the system were optimized. K(+), Na(+), fluorescein sodium, fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used to evaluate the performance of the dual detection system. The limits of detection (LOD) of FD for fluorescein Na(+), FITC, FITC-labeled arginine (Arg), glycine (Gly) and phenylalanine (Phe) were 0.02micromolL(-1), 0.05micromolL(-1), 0.16micromolL(-1), 0.15micromolL(-1), 0.12micromolL(-1) respectively, and the limits of detection (LOD) of CCD achieved 0.58micromolL(-1) and 0.39micromolL(-1) for K(+) and Na(+) respectively.
de Kruijf, Marcel; Govender, Rodney; Yearsley, Dermot; Coffey, Aidan; O'Mahony, Jim
2017-05-01
The aim of this study was to investigate the efficacy of IS_MAP04 as a potential new diagnostic quantitative PCR (qPCR) target for the detection of Mycobacterium avium subspecies paratuberculosis from bovine faeces. IS_MAP04 primers were designed and tested negative against non-MAP strains. The detection limit of IS_MAP04 qPCR was evaluated on different MAP K-10 DNA concentrations and on faecal samples spiked with different MAP K-10 cell dilutions. A collection of 106 faecal samples was analysed and the efficacy of IS_MAP04 was statistically compared with IS900 and IS_MAP02. The detection limits observed for IS_MAP04 and IS900 on MAP DNA was 34 fg and 3.4 fg respectively. The detection limit of MAP from inoculated faecal samples was 10 2 CFU/g for both IS_MAP04 and IS900 targets and a detection limit of 10 2 CFU/g was also achieved with a TaqMan qPCR targeting IS_MAP04. The efficacy of IS_MAP04 to detect positive MAP faecal samples was 83.0% compared to 85.8% and 83.9% for IS900 and IS_MAP02 respectively. Strong kappa agreements were observed between IS_MAP04 and IS900 (κ=0.892) and between IS_MAP04 and IS_MAP02 (κ=0.897). As a new molecular target, IS_MAP04 showed that the detection limit was comparable to IS900 to detect MAP from inoculated faecal material. The MAP detection efficacy of IS_MAP04 from naturally infected faecal samples proved to be relatively comparable to IS_MAP02, but yielded efficacy results slightly less than IS900. Moreover, IS_MAP04 could be of significant value when used in duplex or multiplex qPCR assays. Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Jingjing; Du, Xuezhong
2014-10-07
Sensitive electrochemical sensors were fabricated with reduced graphene oxide-supported Au@Pd (Au@Pd-RGO) nanocomposites by one-step synthesis for individual and simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) with low detection limits and wide concentration ranges. From the Au@Pd-RGO-modified electrodes, well-separated oxidation peaks and enhanced peak currents of AA, DA, and UA were observed owing to the superior conductivity of RGO and the excellent catalytic activity of Au@Pd nanoparticles. For individual detection, the linear responses of AA, DA, and UA were in the concentration ranges of 0.1-1000, 0.01-100, and 0.02-500 μM with detection limits of 0.02, 0.002, and 0.005 μM (S/N = 3), respectively. For simultaneous detection by synchronous change of the concentrations of AA, DA, and UA, the linear response ranges were 1-800, 0.1-100, and 0.1-350 μM with detection limits of 0.28, 0.024, and 0.02 μM (S/N = 3), respectively. The fabricated sensors were further applied to the detection of AA, DA, and UA in urine samples. The Au@Pd-RGO nanocomposites have promising applications in highly sensitive and selective electrochemical sensing.
Dissipation of Pendimethalin in Soybean Crop Under Field Conditions.
Tandon, Shishir
2016-05-01
Persistence of pendimethalin was studied in soil, soybean pods, straw and water under field conditions. Pendimethalin was applied at 1 and 2 kg a.i. ha(-1). Residues in soil were detected up to 60 and 90 days at the recommended and double dose, respectively. Dissipation followed first order kinetics and was accounted for by a biphasic pattern. The half-life for the initial phase and later phase was 12.73 and 26.60 days, respectively, for recommended and 7.25 and 37.91 days, respectively, for double dose. The limit of quantification was 0.005 µg g(-1) of sample. Percent recovery from soil, oil, defatted cake, straw and water samples fortified with 0.01-1.0 mg kg(-1) varied from 84.5 %-89.6 %, 84.6 %-88.7 %, 79.4 %-86.0 %, 78.2 %-85.6 % and 90.2 %-93.0 %, respectively. At harvest, pendimethalin residue in soybean pods, straw, and soil were below detectable limits. No residues of pendimethalin were detected in ground water. Current application of pendimethalin in the environment is not expected to cause adverse health effects form the consumption of soybeans.
Jahanbani, Shahriar; Benvidi, Ali
2016-11-15
In this research, we have improved two aptasensors based on a modified carbon paste electrode (CPE) with oleic acid (OA), and a magnetic bar carbon paste electrode (MBCPE) with Fe3O4 magnetic nanoparticles and oleic acid (OA). After the immobilization process of anti-TET at the electrode surfaces, the aptasensors were named CPE/OA/anti-TET and MBCPE/Fe3O4NPs/OA/anti-TET respectively. In this paper, the detection of tetracycline is compared using CPE/OA/anti-TET and MBCPE/Fe3O4NPs/OA/anti-TET aptasensors. These modified electrodes were characterized by infrared spectroscopy (IR), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), UV-vis spectroscopy, and voltammetric methods. The linear range and the detection limit for TET with the CPE/OA/anti-TET aptasensor were found to be 1.0×10(-12)-1.0×10(-7)M and 3.0×10(-13)M respectively by EIS method. The linear range and the detection limit for TET with the CPE/OA/anti-TET aptasensor were found to be 1.0×10(-10)-1.0×10(-7)M with a limit of detection of 2.9×10(-11)M using differential pulse voltammetry (DPV) technique. The MBCPE/Fe3O4NPs/OA/anti-TET aptasensor was used for determination of TET, and a liner range of 1.0×10(-14)-1.0×10(-6)M with a detection limit of 3.8×10(-15)M was obtained by EIS method. Also, the linear range and detection limit of 1.0×10(-12)-1.0×10(-6)M and 3.1×10(-13)M respectively, were obtained for MBCPE/Fe3O4NPs/OA/anti-TET aptasensor using DPV. The proposed aptasensors were applied for determination of tetracycline in some real samples such as drug, milk, honey and blood serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Ramezani, Mohammad; Abnous, Khalil; Taghdisi, Seyed Mohammad
2017-01-01
Detection and quantitation of antibiotic residues in blood serum and foodstuffs are in great demand. We have developed aptasensors for detection of streptomycin using electrochemical and optical methods. In the first method, an electrochemical aptasensor was developed for sensitive and selective detection of streptomycin, based on combination of exonuclease I (Exo I), complementary strand of aptamer (CS), arch shaped structure of aptamer (Apt)-CS conjugate, and gold electrode. The designed electrochemical aptasensor exhibited high selectivity toward streptomycin with a limit of detection (LOD) as low as 11.4 nM. Moreover, the developed electrochemical aptasensor was successfully used to detect streptomycin in milk and serum with LODs of 14.1 and 15.3 nM, respectively. In the second method, fluorescence quenching and colorimetric aptasensors were designed for detection of streptomycin based on aqueous gold nanoparticles (AuNPs) and double-stranded DNA (dsDNA). In the absence of streptomycin, aptamer/FAM-labeled complementary strand dsDNA is stable, resulting in the aggregation of AuNPs by salt bridge and an obvious color change from red to blue and strong emission of fluorescence. The colorimetric and fluorescence quenching aptasensors showed excellent selectivity toward streptomycin with limit of detections as low as 73.1 and 47.6 nM, respectively. The presented aptasensors were successfully used to detect streptomycin in milk and serum. For serum, LODs were determined to be 58.2 and 102.4 nM for fluorescence quenching and colorimetric aptasensors, respectively. For milk, LODs were calculated to be 56.2 and 108.7 nM for fluorescence quenching and colorimetric aptasensors, respectively.
Fusarium mycotoxin content of UK organic and conventional oats.
Edwards, S G
2009-07-01
Every year between 2002 and 2005 approximately 100 samples of oats from fields of known agronomy were analysed by GC/MS for 10 trichothecenes: deoxynivalenol (DON), nivalenol, 3-acetylDON, 15-acetylDON, fusarenone X, T-2 toxin (T2), HT-2 toxin (HT2), diacetoxyscirpenol, neosolaniol and T-2 triol. Samples were also analysed for moniliformin and zearalenone by HPLC. Of the 10 trichothecenes analysed from 458 harvest samples of oat only three, 15-acetylDON, fusarenone X and diacetoxyscirpenol, were not detected. Moniliformin and zearalenone were absent or rarely detected, respectively. HT2 and T2 were the most frequently detected fusarium mycotoxins, present above the limit of quantification (10 microg kg(-1)) in 92 and 84% of samples, respectively, and were usually present at the highest concentrations. The combined mean and median for HT2 and T2 (HT2 + T2) was 570 and 213 microg kg(-1), respectively. There were good correlations between concentrations of HT2 and all other type A trichothecenes detected (T2, T2 triol and neosolaniol). Year and region had a significant effect on HT2 + T2 concentration. There was also a highly significant difference between HT2 + T2 content in organic and conventional samples, with the predicted mean for organic samples five times lower than that of conventional samples. This is the largest difference reported for any mycotoxin level in organic and conventional cereals. No samples exceeded the legal limits for DON or zearalenone in oats intended for human consumption. Legislative limits for HT2 and T2 are currently under consideration by the European Commission. Depending on the limits set for unprocessed oats intended for human consumption, the levels detected here could have serious consequences for the UK oat-processing industry.
Chung, Hyung Suk; Choi, Jeong-Heui; Abd El-Aty, A M; Lee, Young-Jun; Lee, Han Sol; Kim, Sangdon; Jung, Hee-Jung; Kang, Tae-Woo; Shin, Ho-Chul; Shim, Jae-Han
2016-12-01
A simultaneous determination method using solid-phase extraction and liquid chromatography with tandem mass spectrometry was developed to detect and quantify the presence of seven multiclass veterinary antibiotics (13 compounds in total) in surface water samples, which included the effluents of livestock wastewater and sewage treatment plants, as well as the reservoir drainage areas from dense animal farms. The pH of all water samples was adjusted to 2 or 6 before solid-phase extraction using Oasis HLB cartridges. The developed method was fully validated in terms of linearity, method detection limit, method quantitation limit, accuracy, and precision. The linearity of all tested drugs was good, with R 2 determination coefficients ≥ 0.9931. The method detection limits and method quantitation limits were 0.1-74.3 and 0.5-236.6 ng/L, respectively. Accuracy and precision values were 71-120 and 1-17%, respectively. The determination method was successfully applied for monitoring water samples obtained from the Yeongsan River in 2015. The most frequently detected antibiotics were lincomycin (96%), sulfamethazine (90%), sulfamethoxazole (88%), and sulfathiazole (50%); the maximum concentrations of which were 398.9, 1151.3, 533.1, and 307.4 ng/L, respectively. Overall, the greatest numbers and concentrations of detected antibiotics were found in samples from the effluents of livestock wastewater, sewage treatment plants, and reservoir drainage areas. Diverse veterinary antibiotics were present, and their presence was dependent upon the commercial sales and environmental properties of the analytes, the geographical positions of the sampling points, and the origin of the water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hladik, M.L.; Smalling, K.L.; Kuivila, K.M.
2008-01-01
A method was developed for the analysis of over 60 pesticides and degradates in water by HLB solid-phase extraction and gas-chromatography/mass spectrometry. Method recoveries and detection limits were determined using two surface waters with different dissolved organic carbon (DOC) concentrations. In the lower DOC water, recoveries and detection limits were 80%-108% and 1-12 ng/L, respectively. In the higher DOC water, the detection limits were slightly higher (1-15 ng/L). Additionally, surface water samples from four sites were analyzed and 14 pesticides were detected with concentrations ranging from 4 to 1,200 ng/L. ?? 2008 Springer Science+Business Media, LLC.
[Analysis of Cr in soil by LIBS based on conical spatial confinement of plasma].
Lin, Yong-Zeng; Yao, Ming-Yin; Chen, Tian-Bing; Li, Wen-Bing; Zheng, Mei-Lan; Xu, Xue-Hong; Tu, Jian-Ping; Liu, Mu-Hua
2013-11-01
The present study is to improve the sensitivity of detection and reduce the limit of detection in detecting heavy metal of soil by laser induced breakdown spectroscopy (LIBS). The Cr element of national standard soil was regarded as the research object. In the experiment, a conical cavity with small diameter end of 20 mm and large diameter end of 45 mm respectively was installed below the focusing lens near the experiment sample to mainly confine the signal transmitted by plasma and to some extent to confine the plasma itself in the LIBS setup. In detecting Cr I 425.44 nm, the beast delay time gained from experiment is 1.3 micros, and the relative standard deviation is below 10%. Compared with the setup of non-spatial confinement, the spectral intensity of Cr in the soil sample was enhanced more than 7%. Calibration curve was established in the Cr concentration range from 60 to 400 microg x g(-1). Under the condition of spatial confinement, the liner regression coefficient and the limit of detection were 0.997 71 and 18.85 microg x g(-1) respectively, however, the regression coefficient and the limit of detection were 0.991 22 and 36.99 microg x g(-1) without spatial confinement. So, this shows that conical spatial confinement can/improve the sensitivity of detection and enhance the spectral intensity. And it is a good auxiliary function in detecting Cr in the soil by laser induced breakdown spectroscopy.
Sato, Miki; Maeda, Yuki; Ishioka, Toshio; Harata, Akira
2017-11-20
The detection limits and photoionization thresholds of polycyclic aromatic hydrocarbons and their chlorides and nitrides on the water surface are examined using laser two-photon ionization and single-photon ionization, respectively. The laser two-photon ionization methods are highly surface-selective, with a high sensitivity for aromatic hydrocarbons tending to accumulate on the water surface in the natural environment due to their highly hydrophobic nature. The dependence of the detection limits of target aromatic molecules on their physicochemical properties (photoionization thresholds relating to excess energy, molar absorptivity, and the octanol-water partition coefficient) is discussed. The detection limit clearly depends on the product of the octanol-water partition coefficient and molar absorptivity, and no clear dependence was found on excess energy. The detection limits of laser two-photon ionization for these types of molecules on the water surface are formulated.
Pre-oxidation for Colorimetric Sensor Array Detection of VOCs
Lin, Hengwei; Jang, Minseok; Suslick, Kenneth S.
2011-01-01
A disposable pre-oxidation technique is reported that dramatically improves the detection and identification of volatile organic compounds (VOCs) by a colorimetric sensor array. By passing a vapor stream through a tube packed with chromic acid on silica immediately before the colorimetric sensor array, the sensitivity to less reactive VOCs is substantially increased and limits of detection (LODs) are improved ~300-fold, permitting the detection, identification, and discrimination of 20 commonly found indoor VOC pollutants at both their immediately dangerous to life or health (IDLH) and at permissible exposure limits (PEL) concentrations. LODs of these pollutants were on average 1.4% of their respective PELs. PMID:21967478
Weigel, Stefan; Kuhlmann, Jan; Hühnerfuss, Heinrich
2002-08-05
An analytical method is presented, which allows the simultaneous extraction of neutral and acidic compounds from 20-L seawater samples at ambient pH (approximately 8.3). It is based on a solid-phase extraction by means of a polystyrene-divinylbenzene sorbent and gas chromatographic-mass spectrometric detection, and provides detection limits in the lower pg/L range. The method was applied to the screening of samples from different North Sea areas for clofibric acid, diclofenac, ibuprofen, ketoprofen, propyphenazone, caffeine and N,N-diethyl-3-toluamide (DEET). Whereas clofibric acid, caffeine and DEET showed to be present throughout the North Sea in concentrations of up to 1.3, 16 and 1.1 ng/L, respectively, propyphenazone could only be detected after further clean-up. Diclofenac and ibuprofen were found in the estuary of the river Elbe (6.2 and 0.6 ng/L, respectively) but in none of the marine samples. Ketoprofen was below the detection limit in all samples.
Piñeiro, Zulema; Cantos-Villar, Emma; Palma, Miguel; Puertas, Belen
2011-11-09
A validated HPLC method with fluorescence detection for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines is described. Detection conditions for both compounds were optimized (excitation at 279 and 278 and emission at 631 and 598 nm for hydroxytyrosol and tyrosol, respectively). The validation of the analytical method was based on selectivity, linearity, robustness, detection and quantification limits, repeatability, and recovery. The detection and quantification limits in red wines were set at 0.023 and 0.076 mg L(-1) for hydroxytyrosol and at 0.007 and 0.024 mg L(-1) for tyrosol determination, respectively. Precision values, both within-day and between-day (n = 5), remained below 3% for both compounds. In addition, a fractional factorial experimental design was developed to analyze the influence of six different conditions on analysis. The final optimized HPLC-fluorescence method allowed the analysis of 30 nonpretreated Spanish red wines to evaluate their hydroxytyrosol and tyrosol contents.
Quality control of test iodine in urine by spectrophotometry UV-Vis
NASA Astrophysics Data System (ADS)
Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri
2017-12-01
A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.
Dong, Ming; Zheng, Chuantao; Miao, Shuzhuo; Zhang, Yu; Du, Qiaoling; Wang, Yiding; Tittel, Frank K
2017-09-27
A multi-gas sensor system was developed that uses a single broadband light source and multiple carbon monoxide (CO), carbon dioxide (CO₂) and methane (CH₄) pyroelectric detectors by use of the time division multiplexing (TDM) technique. A stepper motor-based rotating system and a single-reflection spherical optical mirror were designed and adopted to realize and enhance multi-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) were performed to study the performance of the sensor system for the three gas species. Effects of the motor rotating period on sensor performances were also investigated and a rotation speed of 0.4π rad/s was required to obtain a stable sensing performance, corresponding to a detection period of ~10 s to realize one round of detection. Based on an Allan deviation analysis, the 1 σ detection limits under static operation are 2.96, 4.54 and 2.84 parts per million in volume (ppmv) for CO, CO₂ and CH₄, respectively and the 1 σ detection limits under dynamic operations are 8.83, 8.69 and 10.29 ppmv for the three gas species, respectively. The reported sensor has potential applications in various fields requiring CO, CO₂ and CH₄ detection such as in coal mines.
Inoue, K; Kato, K; Yoshimura, Y; Makino, T; Nakazawa, H
2000-11-10
A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND approximately 0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 ml of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 ml of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample were 0.01 ng/ml and 0.05 ng/ml, respectively. The method was applied to the determination of bisphenol A in healthy human serum sample, and the obtained detection was 0.32 ng/ml. From these results, the HPLC-ED method should be the most useful in the determination of bisphenol A at low concentration levels in water and biological samples.
Xu, L; Wang, P; Chen, S
1994-06-01
Using TAT and ELISA, 50 samples of pleural effusion and sera from patients infected with non-Legionella pneumophila were detected for antibodies against Legionella pneumophila serogroups 1 and 6, respectively. The average titre and upper limit value (99%, mean + 2.326S) calculated. In addition, a pleural effusion and a serum from a patient with Legionnaire's pneumonia were also detected by TAT and ELISA. The result showed that the titre of this antibody in his pleural effusion was not only over the upper limit, but also higher than that in his serum.
NASA Astrophysics Data System (ADS)
Kong, Dezhao; Liu, Liqiang; Song, Shanshan; Suryoprabowo, Steven; Li, Aike; Kuang, Hua; Wang, Libing; Xu, Chuanlai
2016-02-01
A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan reader, with the calculated limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.04-0.17, 0.06-49, 0.15-0.22, 0.056-0.49 and 0.53-1.05 μg kg-1, respectively. The analytical results of spiked samples were in accordance with the accurate content in the simultaneous detection analysis. This newly developed ICA strip assay is suitable for the on-site detection and rapid initial screening of mycotoxins in cereal samples, facilitating both semi-quantitative and quantitative determination.A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan reader, with the calculated limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.04-0.17, 0.06-49, 0.15-0.22, 0.056-0.49 and 0.53-1.05 μg kg-1, respectively. The analytical results of spiked samples were in accordance with the accurate content in the simultaneous detection analysis. This newly developed ICA strip assay is suitable for the on-site detection and rapid initial screening of mycotoxins in cereal samples, facilitating both semi-quantitative and quantitative determination. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr09171c
Development of an in situ fiber optic Raman system to monitor hydrothermal vents.
Battaglia, Tina M; Dunn, Eileen E; Lilley, Marvin D; Holloway, John; Dable, Brian K; Marquardt, Brian J; Booksh, Karl S
2004-07-01
The development of a field portable fiber optic Raman system modified from commercially available components that can operate remotely on battery power and withstand the corrosive environment of the hydrothermal vents is discussed. The Raman system is designed for continuous monitoring in the deep-sea environment. A 785 nm diode laser was used in conjunction with a sapphire ball fiber optic Raman probe, single board computer, and a CCD detector. Using the system at ambient conditions the detection limits of SO(4)(2-), CO(3)(2-) and NO(3)(-) were determined to be approximately 0.11, 0.36 and 0.12 g l(-1) respectively. Mimicking the cold conditions of the sea floor by placing the equipment in a refrigerator yielded slightly worse detection limits of approximately 0.16 g l(-1) for SO(4)(-2) and 0.20 g l(-1) for NO(3)(-). Addition of minerals commonly found in vent fluid plumes also decreased the detection limits to approximately 0.33 and 0.34 g l(-1) respectively for SO(4)(-2) and NO(3)(-).
Censoring approach to the detection limits in X-ray fluorescence analysis
NASA Astrophysics Data System (ADS)
Pajek, M.; Kubala-Kukuś, A.
2004-10-01
We demonstrate that the effect of detection limits in the X-ray fluorescence analysis (XRF), which limits the determination of very low concentrations of trace elements and results in appearance of the so-called "nondetects", can be accounted for using the statistical concept of censoring. More precisely, the results of such measurements can be viewed as the left random censored data, which can further be analyzed using the Kaplan-Meier method correcting the data for the presence of nondetects. Using this approach, the results of measured, detection limit censored concentrations can be interpreted in a nonparametric manner including the correction for the nondetects, i.e. the measurements in which the concentrations were found to be below the actual detection limits. Moreover, using the Monte Carlo simulation technique we show that by using the Kaplan-Meier approach the corrected mean concentrations for a population of the samples can be estimated within a few percent uncertainties with respect of the simulated, uncensored data. This practically means that the final uncertainties of estimated mean values are limited in fact by the number of studied samples and not by the correction procedure itself. The discussed random-left censoring approach was applied to analyze the XRF detection-limit-censored concentration measurements of trace elements in biomedical samples.
Partially reduced graphene oxide based FRET on fiber optic interferometer for biochemical detection
NASA Astrophysics Data System (ADS)
Yao, B. C.; Wu, Y.; Yu, C. B.; He, J. R.; Rao, Y. J.; Gong, Y.; Chen, Y. F.; Li, Y. R.
2017-04-01
An all-fiber graphene oxide (GO) based 'FRET on Fiber' concept is proposed and applied in biochemical detections. This method is of both good selectivity and high sensitivity, with detection limits of 1.2 nM, 1.3 μM and 1 pM, for metal ion, dopamine and single-stranded DNA (ssDNA), respectively.
Chen, Xi; Chen, Jin; Wang, Fubin; Xiang, Xia; Luo, Ming; Ji, Xinghu; He, Zhike
2012-05-15
In this work, we first employ a drying method combining with the bienzyme colorimetric detection of glucose and uric acid on microfluidic paper-based analysis devices (μPADs). The channels of 3D μPADs are also designed by us to get better results. The color results are recorded by both Gel Documentation systems and a common camera. By using Gel Documentation systems, the limits of detection (LOD) of glucose and uric acid are 3.81 × 10(-5)M and 4.31 × 10(-5)M, respectively one order of magnitude lower than that of the reported methods on μPADs. By using a common camera, the limits of detection (LOD) of glucose and uric acid are 2.13 × 10(-4)M and 2.87 × 10(-4)M, respectively. Furthermore, the effects of detection conditions have been investigated and discussed comprehensively. Human serum samples are detected with satisfactory results, which are comparable with the clinical testing results. A low-cost, simple and rapid colorimetric method for the simultaneous detection of glucose and uric acid on the μPADs has been developed with enhanced sensitivity. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Maganda, Yasin Wandhami
In this research work we developed a highly sensitive analytical Laser Induced Breakdown Spectrometer to detect toxic elements in commercially available cosmetic products. These products are frequently used by many all over the world, therefore there is an increasing demand to determine concentration levels of toxic elements present in them because they cause dangerous diseases and most of them are highly carcinogenic and life threatening. Laser Induced Breakdown Spectroscopy (LIBS) was applied for spectroscopic analysis of cosmetic products such as tooth paste, synthetic hair dye, kohl eyeliners and talcum powder samples. These samples were purchased from the local market within the kingdom of Saudi Arabia. The LIBS method is based on spectroscopic analysis of plasma resulting from the interaction of a high power pulsed laser radiations with a sample medium. In order to improve the sensitivity of the spectrometer, the dependence of the LIBS signal intensity and plasma parameters such as temperature (T) and electron density (ne) on gate/time delay, laser fluence and wavelength of the excitation source for plasma generated under ambient conditions were studied. During this work Nd: YAG lasers having 266nm, 532 nm and 1064 nm wavelengths operating in Q-switch mode were used as the excitation sources in combination with a spectrograph having a gated ICCD camera. Boltzmann plots and stark broadening for the recorded spectral lines were used to estimate the plasma temperature and electron density respectively. Temporal evolution of the plasma temperature and electron density showed a t-2 dependence. On the other hand plasma temperature and electron density increased with increase in laser fluence but leveled off at higher fluencies. It is worth noting that in both cases 266 nm and 1064 nm excitation wavelengths consistently had the highest and lowest values respectively. Therefore a 266 nm wavelength Nd: YAG laser excitation source was selected to develop a highly sensitive Laser Induced Breakdown spectrometer to detect and quantify the fluoride (F), lead (Pb) and chromium (Cr) content in commercially available toothpaste, synthetic hair dye, kohl eyeliners and talcum powder samples. The experimental parameters such as gate/ delays and laser fluencies were optimized to achieve an optically thin and in local thermodynamic equilibrium plasma (L.T.E) which improved the limit of detection of our spectrometer. The choice of the parameters was validated using the Mcwhirter criterion. For fluoride detection in the toothpaste samples, a strong atomic transition line of fluorine at 731.102 nm was used as the marker line. The LIBS system was able to detect fluoride concentration levels in the range of 1300 - 1750 ppm with a detection limit of 156ppm.In the synthetic hair dye, chromium was detected using a strong atomic transition of chromium (Cr) at a wavelength 427.5 nm as the spectral marker line and the spectrometer with a detection limit of 1.2 ppm was able to detect chromium concentration levels in the range of 5-11 ppm. These results achieved with our LIBS system were compared with those obtained using a standard detection method such as ICP-MS. The results obtained are in excellent agreement with ICP-MS. Lead (Pb) and Chromium (Cr) in kohl were detected using atomic transitions at wavelengths of 405.7 nm and 425.4 nm respectively as the spectral marker lines. The system was calibrated for these toxic metals and it was able to detect Lead and Chromium in the range of 5-14 ppm and 4-9 ppm with detection limits of 1ppm and 2 ppm respectively. The LIBS results were compared with those obtained using ICP-MS and were in good agreement yielding a relative accuracy in the range 0.05-0.3 which is acceptable. Lead (Pb) and Chromium (Cr) levels in talcum powder samples were detected and quantified using strong transitions at wavelengths of 405.7 nm and 425.4 nm respectively. The LIBS system detected lead and chromium in the range of 15-17 ppm and 23-29 ppm with limits of detection of 1.96 ppm and 1.72 ppm respectively. The concentration levels of fluoride, lead and chromium detected using our LIBS system exceeded the permissible limits set by the Environmental agency and other regulatory organization and hence frequent use of such cosmetic products can be hazardous to human health. The LIBS spectrometer developed through this research work can be applied for analysis of many other samples like pharmaceutical, polymers, iron, volcanic eruption and geological samples for mineral quantification.
Samouëlian, Vanessa; Mechtouf, Nawel; Leblanc, Eric; Cardin, Guillaume B; Lhotellier, Valérie; Querleu, Denis; Révillion, Françoise; Rodier, Francis
2018-04-24
Metastatic nodal involvement is a critical prognostic factor in uterine cervical cancer (UCC). To improve current methods of detecting UCC metastases in lymph nodes (LNs), we used quantitative PCR (qPCR) to assess mRNA expression of potential metastatic biomarkers. We found that expression of HPV16-E6, cytokeratin19 (CK19), and mucin1 (MUC1) is consistently upregulated in tumors and metastatic tissues, supporting a role for these genes in UCC progression. These putative biomarkers were able to predict the presence of histologically positive metastatic LNs with respective sensitivities and specificities of 82% and 99% (CK19), 76% and 95% (HPV16-E6), and 76% and 78% (MUC1). While the biomarkers failed to detect 1.7% to 2.2% of the histologically positive LNs when used individually, combining CK19 and HPV16-E6 enhanced sensitivity and specificity to 100% and 94%, respectively. To explore the sensitivity of qPCR-based detection of varying proportions of invading HPV16-positive UCC cells, we designed a LN metastasis model that achieved a fresh cell detection limit of 0.008% (1:12500 HPV16-positive to HPV16-negative cells), and a paraffin-embedded, formalin-fixed (PEFF) detection limit of 0.02% (1:5000 HPV16-positive to HPV16-negative cells), both of which are within the theoretical detection limit for micrometastasis. Thus, HPV E6/E7 oncogenes may be useful targets for the ultrasensitive detection of nodal involvements like micrometastases in fresh or archived tissue samples. Moreover, our results suggest that the biomarker combination of CK19/HPV-E6 could support a real-time intraoperative strategy for the detection of small, but potentially lethal, metastatic nodal involvements in fresh UCC tissues.
Chen, Li-Xian; Zheng, Jie-Ning; Wang, Ai-Jun; Wu, Lan-Ju; Chen, Jian-Rong; Feng, Jiu-Ju
2015-05-07
Porous bimetallic alloyed palladium silver (PdAg) nanoflowers supported on reduced graphene oxide (PdAg NFs/rGO) were prepared via a facile and simple in situ reduction process, with the assistance of cetyltrimethylammonium bromide as a structure directing agent. The as-prepared nanocomposite modified glassy carbon electrode (PdAg NFs/rGO/GCE) showed enhanced catalytic currents and enlarged peak potential separations for the oxidation of ascorbic acid (AA), dopamine (DA), and uric acid (UA) as compared to those of PdAg/GCE, rGO/GCE, commercial Pd/C/GCE, and bare GCE. The as-developed sensor can selectively detect AA, DA, and UA with a good anti-interference ability, wide concentration ranges of 1.0 μM-2.1 mM, 0.4-96.0 μM, and 1.0-150.0 μM, respectively, together with low detection limits of 0.057, 0.048, and 0.081 μM (S/N = 3), respectively. For simultaneous detection of AA, DA, and UA, the linear current-concentration responses were observed from 1.0 μM-4.1 mM, 0.05-112.0 μM, and 3.0-186.0 μM, with the detection limits of 0.185, 0.017, and 0.654 μM (S/N = 3), respectively.
Liu, Yan-Ming; Shi, Yan-Mei; Liu, Zhuan-Li; Peng, Long-Fei
2010-05-01
A sensitive approach for the simultaneous determination of tilmicosin, erythromycin ethylsuccinate and clindamycin was developed by CE coupled with electrochemiluminescence detection with ionic liquid. The parameters for CE, electrochemiluminescence detection and the effect of ionic liquid were investigated systematically. The three analytes were well separated and detected within 8 min. The limits of detection (S/N=3) of tilmicosin, erythromycin ethylsuccinate and clindamycin are 3.4x10(-9), 2.3x10(-8) and 1.3x10(-8) mol/L, respectively. The precisions (RSD%) of the peak area and the migration time are from 0.8 to 1.5% and from 0.2 to 0.5% within a day and from 1.8 to 2.7% and from 0.6 to 0.8% in 3 days, respectively. The limits of quantitation (S/N=10) of tilmicosin, erythromycin ethylsuccinate and clindamycin are 3.2x10(-8), 2.9x10(-7) and 9.1x10(-8) mol/L in human urines and 5.5x10(-8), 3.2x10(-7) and 2.1x10(-7) mol/L in milk samples, respectively. The recoveries of three analytes at different concentration levels in urine, milk and drugs are between 90.0 and 104.7%. The proposed method was successfully applied to the determination of three analytes in human urine, milk and drugs.
Shojaei, Taha Roodbar; Mohd Salleh, Mohamad Amran; Tabatabaei, Meisam; Ekrami, Alireza; Motallebi, Roya; Rahmani-Cherati, Tavoos; Hajalilou, Abdollah; Jorfi, Raheleh
2014-01-01
Mycobacterium tuberculosis, the causing agent of tuberculosis, comes second only after HIV on the list of infectious agents slaughtering many worldwide. Due to the limitations behind the conventional detection methods, it is therefore critical to develop new sensitive sensing systems capable of quick detection of the infectious agent. In the present study, the surface modified cadmium-telluride quantum dots and gold nanoparticles conjunct with two specific oligonucleotides against early secretory antigenic target 6 were used to develop a sandwich-form fluorescence resonance energy transfer-based biosensor to detect M. tuberculosis complex and differentiate M. tuberculosis and M. bovis Bacille Calmette-Guerin simultaneously. The sensitivity and specificity of the newly developed biosensor were 94.2% and 86.6%, respectively, while the sensitivity and specificity of polymerase chain reaction and nested polymerase chain reaction were considerably lower, 74.2%, 73.3% and 82.8%, 80%, respectively. The detection limits of the sandwich-form fluorescence resonance energy transfer-based biosensor were far lower (10 fg) than those of the polymerase chain reaction and nested polymerase chain reaction (100 fg). Although the cost of the developed nanobiosensor was slightly higher than those of the polymerase chain reaction-based techniques, its unique advantages in terms of turnaround time, higher sensitivity and specificity, as well as a 10-fold lower detection limit would clearly recommend this test as a more appropriate and cost-effective tool for large scale operations. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.
Constraining Accretion Signatures of Exoplanets in the TW Hya Transitional Disk
NASA Astrophysics Data System (ADS)
Uyama, Taichi; Tanigawa, Takayuki; Hashimoto, Jun; Tamura, Motohide; Aoyama, Yuhiko; Brandt, Timothy D.; Ishizuka, Masato
2017-09-01
We present a near-infrared direct imaging search for accretion signatures of possible protoplanets around the young stellar object (YSO) TW Hya, a multi-ring disk exhibiting evidence of planet formation. The Paβ line (1.282 μm) is an indication of accretion onto a protoplanet, and its intensity is much higher than that of blackbody radiation from the protoplanet. We focused on the Paβ line and performed Keck/OSIRIS spectroscopic observations. Although spectral differential imaging (SDI) reduction detected no accretion signatures, the results of the present study allowed us to set 5σ detection limits for Paβ emission of 5.8 × 10-18 and 1.5 × 10-18 erg-1 s-1 cm-2 at 0.″4 and 1.″6, respectively. We considered the mass of potential planets using theoretical simulations of circumplanetary disks and hydrogen emission. The resulting masses were 1.45 ± 0.04 M J and {2.29}-0.04+0.03 {M}{{J}} at 25 and 95 au, respectively, which agree with the detection limits obtained from previous broadband imaging. The detection limits should allow for the identification of protoplanets as small as ˜1 M J, which may assist in direct imaging searches around faint YSOs for which extreme adaptive optics instruments are unavailable.
Development of ochratoxin a in cereal by chemiluminescence enzyme immunoassay
NASA Astrophysics Data System (ADS)
Li, Min; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen
2017-11-01
A rapid, simple and sensitive chemiluminescence enzyme immunoassay method (CLEIA) was established to detect ochratoxin A (OTA) in cereal. Optimal conditions including antibody dilution ratio and enzyme conjugate, ionic strength, pH value and organic solvent. Established indirect competition inhibition curve to determine the linear working range, detection limit and recovery rate. Results: The 50% inhibitory concentration and the detection limit of the CLEIA were78.8pg/mL and 14.86 pg/mL, respectively, with a linear range of 0.015-0.4ng/mL. At 1∼4μpg/kg fortified levels in wheat, mean recoveries ranged from 67.47% to100.35%.
Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection.
Tam, Maggie; Hill, Herbert H
2004-05-15
The unique capability of secondary electrospray ionization (SESI) as a nonradioactive ionization source to detect analytes in both liquid and gaseous samples was evaluated using aqueous solutions of three common military explosives: cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), nitroglycerin (NG) and pentaerythritol tetranitrate (PETN). The adducts formed between the compounds and their respective dissociation product, RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-), gave the most intense signal for the individual compound but were more sensitive to temperature than other species. These autoadducts were identified as RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-) and had maximum signal intensity at 137, 100, and 125 degrees C, respectively. The reduced mobility values of the three compounds were constant over the temperature range from 75 to 225 degrees C. The signal-to-noise ratios for RDX, NG, and PETN at 50 mg L(-1) in methanol-water were 340, 270, and 170, respectively, with a nominal noise of 8 +/- 2 pA. In addition to the investigation of autoadduct formation, the concept of doping the ionization source with nonvolatile adduct-forming agents was investigated and described for the first time. The SESI-IMS detection limit for RDX was 116 microg L(-1) in the presence of a traditional volatile chloride dopant and 5.30 microg L(-1) in the presence of a nonvolatile nitrate dopant. In addition to a lower detection limit, the nitrate dopant also produced a greater response sensitivity and a higher limit of linearity than did the traditional volatile chloride dopant.
Automated quantification of myocardial perfusion SPECT using simplified normal limits.
Slomka, Piotr J; Nishina, Hidetaka; Berman, Daniel S; Akincioglu, Cigdem; Abidov, Aiden; Friedman, John D; Hayes, Sean W; Germano, Guido
2005-01-01
To simplify development of normal limits for myocardial perfusion SPECT (MPS), we implemented a quantification scheme in which normal limits are derived without visual scoring of abnormal scans or optimization of regional thresholds. Normal limits were derived from same-day TI-201 rest/Tc-99m-sestamibi stress scans of male (n = 40) and female (n = 40) low-likelihood patients. Defect extent, total perfusion deficit (TPD), and regional perfusion extents were derived by comparison to normal limits in polar-map coordinates. MPS scans from 256 consecutive patients without known coronary artery disease, who underwent coronary angiography, were analyzed. The new method of quantification (TPD) was compared with our previously developed quantification system and visual scoring. The receiver operator characteristic area under the curve for detection of 50% or greater stenoses by TPD (0.88 +/- 0.02) was higher than by visual scoring (0.83 +/- 0.03) ( P = .039) or standard quantification (0.82 +/- 0.03) ( P = .004). For detection of 70% or greater stenoses, it was higher for TPD (0.89 +/- 0.02) than for standard quantification (0.85 +/- 0.02) ( P = .014). Sensitivity and specificity were 93% and 79%, respectively, for TPD; 81% and 85%, respectively, for visual scoring; and 80% and 73%, respectively, for standard quantification. The use of stress mode-specific normal limits did not improve performance. Simplified quantification achieves performance better than or equivalent to visual scoring or quantification based on per-segment visual optimization of abnormality thresholds.
Shaikh, K A; Patil, S D; Devkhile, A B
2008-12-15
A simple, precise and accurate reversed-phase liquid chromatographic method has been developed for the simultaneous estimation of ambroxol hydrochloride and azithromycin in tablet formulations. The chromatographic separation was achieved on a Xterra RP18 (250 mm x 4.6 mm, 5 microm) analytical column. A Mixture of acetonitrile-dipotassium phosphate (30 mM) (50:50, v/v) (pH 9.0) was used as the mobile phase, at a flow rate of 1.7 ml/min and detector wavelength at 215 nm. The retention time of ambroxol and azithromycin was found to be 5.0 and 11.5 min, respectively. The validation of the proposed method was carried out for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The linear dynamic ranges were from 30-180 to 250-1500 microg/ml for ambroxol hydrochloride and azithromycin, respectively. The percentage recovery obtained for ambroxol hydrochloride and azithromycin were 99.40 and 99.90%, respectively. Limit of detection and quantification for azithromycin were 0.8 and 2.3 microg/ml, for ambroxol hydrochloride 0.004 and 0.01 microg/ml, respectively. The developed method can be used for routine quality control analysis of titled drugs in combination in tablet formulation.
Ermolli, M; Prospero, A; Balla, B; Querci, M; Mazzeo, A; Van Den Eede, G
2006-09-01
An innovative immunoassay, called enzyme-linked immunoabsorbant assay (ELISA) Reverse, based on a new conformation of the solid phase, was developed. The solid support was expressly designed to be immersed directly in liquid samples to detect the presence of protein targets. Its application is proposed in those cases where a large number of samples have to be screened simultaneously or when the simultaneous detection of different proteins is required. As a first application, a quantitative immunoassay for Cry1AB protein in genetically modified maize was optimized. The method was tested using genetically modified organism concentrations from 0.1 to 2.0%. The limit of detection and limit of quantitation of the method were determined as 0.0056 and 0.0168 (expressed as the percentage of genetically modified organisms content), respectively. A qualitative multiplex assay to assess the presence of two genetically modified proteins simultaneously was also established for the case of the Cry1AB and the CP4EPSPS (5-enolpyruvylshikimate-3-phosphate synthase) present in genetically modified maize and soy, respectively.
Development and Measurements of a Mid-Infrared Multi-Gas Sensor System for CO, CO2 and CH4 Detection
Dong, Ming; Zheng, Chuantao; Miao, Shuzhuo; Zhang, Yu; Du, Qiaoling; Wang, Yiding
2017-01-01
A multi-gas sensor system was developed that uses a single broadband light source and multiple carbon monoxide (CO), carbon dioxide (CO2) and methane (CH4) pyroelectric detectors by use of the time division multiplexing (TDM) technique. A stepper motor-based rotating system and a single-reflection spherical optical mirror were designed and adopted to realize and enhance multi-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) were performed to study the performance of the sensor system for the three gas species. Effects of the motor rotating period on sensor performances were also investigated and a rotation speed of 0.4π rad/s was required to obtain a stable sensing performance, corresponding to a detection period of ~10 s to realize one round of detection. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 2.96, 4.54 and 2.84 parts per million in volume (ppmv) for CO, CO2 and CH4, respectively and the 1σ detection limits under dynamic operations are 8.83, 8.69 and 10.29 ppmv for the three gas species, respectively. The reported sensor has potential applications in various fields requiring CO, CO2 and CH4 detection such as in coal mines. PMID:28953260
Censoring: a new approach for detection limits in total-reflection X-ray fluorescence
NASA Astrophysics Data System (ADS)
Pajek, M.; Kubala-Kukuś, A.; Braziewicz, J.
2004-08-01
It is shown that the detection limits in the total-reflection X-ray fluorescence (TXRF), which restrict quantification of very low concentrations of trace elements in the samples, can be accounted for using the statistical concept of censoring. We demonstrate that the incomplete TXRF measurements containing the so-called "nondetects", i.e. the non-measured concentrations falling below the detection limits and represented by the estimated detection limit values, can be viewed as the left random-censored data, which can be further analyzed using the Kaplan-Meier (KM) method correcting for nondetects. Within this approach, which uses the Kaplan-Meier product-limit estimator to obtain the cumulative distribution function corrected for the nondetects, the mean value and median of the detection limit censored concentrations can be estimated in a non-parametric way. The Monte Carlo simulations performed show that the Kaplan-Meier approach yields highly accurate estimates for the mean and median concentrations, being within a few percent with respect to the simulated, uncensored data. This means that the uncertainties of KM estimated mean value and median are limited in fact only by the number of studied samples and not by the applied correction procedure for nondetects itself. On the other hand, it is observed that, in case when the concentration of a given element is not measured in all the samples, simple approaches to estimate a mean concentration value from the data yield erroneous, systematically biased results. The discussed random-left censoring approach was applied to analyze the TXRF detection-limit-censored concentration measurements of trace elements in biomedical samples. We emphasize that the Kaplan-Meier approach allows one to estimate the mean concentrations being substantially below the mean level of detection limits. Consequently, this approach gives a new access to lower the effective detection limits for TXRF method, which is of prime interest for investigation of metallic impurities on the silicon wafers.
Spectroscopic Detection of Glyphosate in Water Assisted by Laser-Ablated Silver Nanoparticles
De Góes, Rafael Eleodoro; Muller, Marcia; Fabris, José Luís
2017-01-01
Glyphosate is one of the most widely used herbicides in the world. Its safety for both human health and aquatic biomes is a subject of wide debate. There are limits to glyphosate’s presence in bodies of water, and it is usually detected through complex analytical procedures. In this work, the presence of glyphosate is detected directly through optical interrogation of aqueous solution. For this purpose, silver nanoparticles were produced by pulsed laser ablation in liquids. Limits of detection of 0.9 mg/L and 3.2 mg/L were obtained with UV-Vis extinction and Surface Enhanced Raman spectroscopies, respectively. The sensing mechanism was evaluated in the presence of potential interferents as well as with commercial glyphosate-based herbicides. PMID:28445394
Determination of patulin in commercial apple juice by micellar electrokinetic chromatography.
Murillo, M; González-Peñas, E; Amézqueta, S
2008-01-01
A novel and validated micellar electrokinetic capillary chromatography (MEKC) method using ultraviolet detection (UV) has been applied to the quantitative analysis of patulin (PAT) in commercial apple juice. Patulin was extracted from samples with an ethylacetate solution. The micellar electrokinetic capillary chromatography (MECK) parameters studied for method optimization were buffer composition, voltage, temperature, and a separation between PAT and 5-hydroxymethylfurfural (HMF) (main interference in apple juice PAT analysis) peaks until reaching baseline. The method passes a series of validation tests including selectivity, linearity, limit of detection and quantification (0.7 and 2.5 microgL(-1), respectively), precision (within and between-day variability) and recovery (80.2% RSD=4%), accuracy, and robustness. This method was successfully applied to the measurement of 20 apple juice samples obtained from different supermarkets. One hundred percent of the samples were contaminated with a level greater than the limit of detection, with mean and median values of 41.3 and 35.7 microgL(-1), respectively.
Louveau, B; Fernandez, C; Zahr, N; Sauvageon-Martre, H; Maslanka, P; Faure, P; Mourah, S; Goldwirt, L
2016-12-01
A precise and accurate high-performance liquid chromatography (HPLC) quantification method of rifampicin in human plasma was developed and validated using ultraviolet detection after an automatized solid-phase extraction. The method was validated with respect to selectivity, extraction recovery, linearity, intra- and inter-day precision, accuracy, lower limit of quantification and stability. Chromatographic separation was performed on a Chromolith RP 8 column using a mixture of 0.05 m acetate buffer pH 5.7-acetonitrile (35:65, v/v) as mobile phase. The compounds were detected at a wavelength of 335 nm with a lower limit of quantification of 0.05 mg/L in human plasma. Retention times for rifampicin and 6,7-dimethyl-2,3-di(2-pyridyl) quinoxaline used as internal standard were respectively 3.77 and 4.81 min. This robust and exact method was successfully applied in routine for therapeutic drug monitoring in patients treated with rifampicin. Copyright © 2016 John Wiley & Sons, Ltd.
Bellomarino, Sara A; Brown, Allyson J; Conlan, Xavier A; Barnett, Neil W
2009-03-15
High-performance liquid chromatography (HPLC) with tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection methodology is reported for the determination of the atypical antipsychotic drug quetiapine and the observation of its major active and inactive metabolites in human urine and serum. The method uses a monolithic chromatographic column allowing high flow rates of 3 mLmin(-1) enabling rapid quantification. Flow injection analysis (FIA) with tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection and HPLC time of flight mass spectrometry (TOF-MS) were used for the determination of quetiapine in a pharmaceutical preparation to establish its suitability as a calibration standard. The limit of detection achieved with FIA was 2 x 10(-11) molL(-1) in simple aqueous solution. The limits of detection achieved with HPLC were 7 x 10(-8) and 2 x 10(-10) molL(-1) in urine and serum, respectively. The calibration range for FIA was between 5 x 10(-9) and 1 x 10(-6) molL(-1). The calibration ranges for HPLC were between 1 x 10(-7)-1 x 10(-4) and 1 x 10(-8)-1 x 10(-4) molL(-1) in urine and serum, respectively. The quetiapine concentrations in patient samples were found to be 3 x 10(-6) molL(-1) in urine and 7 x 10(-7) molL(-1) in serum. Without the need for preconcentration, the HPLC detection limits compared favourably with those in previously published methodologies. The metabolites were identified using HPLC-TOF-MS.
Ulu, Sevgi Tatar; Tuncel, Muzaffer
2012-05-01
A novel pre-column derivatization reversed-phase high-performance liquid chromatography with fluorescence detection is described for the determination of bupropion in pharmaceutical preparation, human plasma and human urine using mexiletine as internal standard. The proposed method is based on the reaction of 4-chloro-7-nitrobenzofurazan (NBD-Cl) with bupropion to produce a fluorescent derivative. The derivative formed is monitored on a C18 (150 mm × 4.6 mm i.d., 5 µm) column using a mobile phase consisting of methanol-water 75:25 (v/v), at a flow-rate of 1.2 mL/min and detected fluorimetrically at λ(ex) = 458 and λ(em) = 533 nm. The assay was linear over the concentration ranges of 5-500 and 10-500 ng/mL for plasma and urine, respectively. The limits of detection and quantification were calculated to be 0.24 and 0.72 ng/mL for plasma and urine, respectively (inter-day results). The recoveries obtained for plasma and urine were 97.12% ± 0.45 and 96.00% ± 0.45, respectively. The method presents good performance in terms of precision, accuracy, specificity, linearity, detection and quantification limits and robustness. The proposed method is applied to determine bupropion in commercially available tablets. The results were compared with an ultraviolet spectrophotometry method using t- and F-tests. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Huang, Hsin-Yi; Chen, Po-Yu
2010-12-15
Nonenzymatic electrochemical determination of ethanol and glucose was respectively achieved using PdNi- and Pd-coated electrodes prepared by electrodeposition from the novel metal-free ionic liquid (IL); N-butyl-N-methylpyrrolidinium dicyanamide (BMP-DCA). BMP-DCA provided an excellent environment and wide cathodic limit for electrodeposition of metals and alloys because many metal chlorides could dissolve in this IL where the reduction potentials of Pd(II) and Ni(II) indeed overlapped, leading to the convenience of potentiostatic codeposition. In aqueous solutions, the reduction potentials of Pd(II) and Ni(II) are considerably separated. The bimetallic PdNi coatings with atomic ratios of ∼ 80/20 showed the highest current for ethanol oxidation reaction (EOR). Ethanol was detected by either cyclic voltammetry (CV) or hydrodynamic amperometry (HA). Using CV, the dependence of EOR peak current on concentration was linear from 4.92 to 962 μM with a detection limit of 2.26 μM (σ=3), and a linearity was observed from 4.92 to 988 μM using HA (detection limit 0.83 μM (σ=3)). The Pd-coated electrodes prepared by electrodeposition from BMP-DCA showed electrocatalytic activity to glucose oxidation and CV, HA, and square-wave voltammetry (SWV) were employed to determine glucose. SWV showed the best sensitivity and linearity was observed from 2.86 μM to 107 μM, and from 2.99 mM to 10.88 mM with detection limits of 0.78 μM and 25.9 μM (σ=3), respectively. For glucose detection, the interference produced from ascorbic acid, uric acid, and acetaminophen was significantly suppressed, compared with a regular Pt disk electrode. Copyright © 2010 Elsevier B.V. All rights reserved.
Karageorgou, Eftychia; Christoforidou, Sofia; Ioannidou, Maria; Psomas, Evdoxios; Samouris, Georgios
2018-06-01
The present study was carried out to assess the detection sensitivity of four microbial inhibition assays (MIAs) in comparison with the results obtained by the High Performance Liquid Chromatography with Diode-Array Detection (HPLC-DAD) method for antibiotics of the β-lactam group and chloramphenicol in fortified raw milk samples. MIAs presented fairly good results when detecting β-lactams, whereas none were able to detect chloramphenicol at or above the permissible limits. HPLC analysis revealed high recoveries of examined compounds, whereas all detection limits observed were lower than their respective maximum residue limits (MRL) values. The extraction and clean-up procedure of antibiotics was performed by a modified matrix solid phase dispersion procedure using a mixture of Plexa by Agilent and QuEChERS as a sorbent. The HPLC method developed was validated, determining the accuracy, precision, linearity, decision limit, and detection capability. Both methods were used to monitor raw milk samples of several cows and sheep, obtained from producers in different regions of Greece, for the presence of examined antibiotic residues. Results obtained showed that MIAs could be used effectively and routinely to detect antibiotic residues in several milk types. However, in some cases, spoilage of milk samples revealed that the kits' sensitivity could be strongly affected, whereas this fact does not affect the effectiveness of HPLC-DAD analysis.
Lee, Gyeong-Hweon; Bang, Dae-Young; Lim, Jung-Hoon; Yoon, Seok-Min; Yea, Myeong-Jai; Chi, Young-Min
2017-10-15
In this study, a rapid method for simultaneous detection of ethyl carbamate (EC) and urea in Korean rice wine was developed. To achieve quantitative analysis of EC and urea, the conditions for Ultra-performance liquid chromatography (UPLC) separation and atmospheric-pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) detection were first optimized. Under the established conditions, the detection limit, relative standard deviation and linear range were 2.83μg/L, 3.75-5.96%, and 0.01-10.0mg/L, respectively, for urea; the corresponding values were 0.17μg/L, 1.06-4.01%, and 1.0-50.0μg/L, respectively, for EC. The correlation between the contents of EC and its precursor urea was determined under specific pH (3.5 and 4.5) and temperature (4, 25, and 50°C) conditions using the developed method. As a result, EC content was increased with greater temperature and lower pH. In Korean rice wine, urea was detected 0.19-1.37mg/L and EC was detected 2.0-7.7μg/L. The method developed in this study, which has the advantages of simplified sample preparation, low detection limits, and good selectivity, was successfully applied for the rapid analysis of EC and urea. Copyright © 2017 Elsevier B.V. All rights reserved.
CO and CO2 dual-gas detection based on mid-infrared wideband absorption spectroscopy
NASA Astrophysics Data System (ADS)
Dong, Ming; Zhong, Guo-qiang; Miao, Shu-zhuo; Zheng, Chuan-tao; Wang, Yi-ding
2018-03-01
A dual-gas sensor system is developed for CO and CO2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing (TDM) technique. A stepper motor based rotating system and a single-reflection spherical optical mirror are designed and adopted for realizing and enhancing dual-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) are performed to study the performance of the sensor system for the two gas samples. The detection period is 7.9 s in one round of detection by scanning the two detectors. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 3.0 parts per million (ppm) in volume and 2.6 ppm for CO and CO2, respectively, and those under dynamic operation are 9.4 ppm and 10.8 ppm for CO and CO2, respectively. The reported sensor has potential applications in various fields requiring CO and CO2 detection such as in the coal mine.
NASA Astrophysics Data System (ADS)
Prudhomme, G.; Berthe, L.; Bénier, J.; Bozier, O.; Mercier, P.
2017-01-01
Photonic Doppler Velocimetry is a plug-and-play and versatile diagnostic used in dynamic physic experiments to measure velocities. When signals are analyzed using a Short-Time Fourier Transform, multiple velocities can be distinguished: for example, the velocities of moving particle-cloud appear on spectrograms. In order to estimate the back-scattering fluxes of target, we propose an original approach "PDV Radiometric analysis" resulting in an expression of time-velocity spectrograms coded in power units. Experiments involving micron-sized particles raise the issue of detection limit; particle-size limit is very difficult to evaluate. From the quantification of noise sources, we derive an estimation of the spectrogram noise leading to a detectivity limit, which may be compared to the fraction of the incoming power which has been back-scattered by the particle and then collected by the probe. This fraction increases with their size. At last, some results from laser-shock accelerated particles using two different PDV systems are compared: it shows the improvement of detectivity with respect to the Effective Number of Bits (ENOB) of the digitizer.
Aflatoxin B1 and sterigmatocystin survey in beer sold in China.
Zhao, Yarong; Huang, Jianxiang; Ma, Liyan; Liu, Shuai; Wang, Fuhua
2017-03-01
A total of 101 samples of beer from the Chinese market were analysed for the presence of aflatoxin B 1 (AFB 1 ) and sterigmatocystin (STC), using methods based on liquid chromatography-tandem mass spectrometry. The limit of quantification and the limit of detection in beer were 0.1 and 0.03 µg/kg, respectively. Recoveries of AFB 1 and STC from spiked beer samples were 97.8-103.6% and 92.7-102.1%, respectively. None of the beer purchased samples were contaminated with AFB 1 or STC.
Influence of VO2 Nanoparticle Morphology on the Colorimetric Assay of H2O2 and Glucose
Tian, Rui; Sun, Jiaheng; Qi, Yanfei; Zhang, Boyu; Guo, Shuanli; Zhao, Mingming
2017-01-01
Nanozyme-based colorimetric sensors have received considerable attention due to their unique properties. The size, shape, and surface chemistry of these nanozymes could dramatically influence their sensing behaviors. Herein, a comparative study of VO2 nanoparticles with different morphologies (nanofibers, nanosheets, and nanorods) was conducted and applied to the sensitive colorimetric detection of H2O2 and glucose. The peroxidase-like activities and mechanisms of VO2 nanoparticles were analyzed. Among the VO2 nanoparticles, VO2 nanofibers exhibited the best peroxidase-like activity. Finally, a comparative quantitative detections of H2O2 and glucose were done on fiber, sheet, and rod nanoparticles. Under the optimal reaction conditions, the lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for H2O2 are found to be 0.018, 0.266, and 0.41 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for H2O2 from 0.025–10, 0.488–62.5, and 0.488–15.625 mM, respectively. The lower limit of detection (LOD) of the VO2 nanofibers, nanosheets, and nanorods for glucose are found to be 0.009, 0.348, and 0.437 mM, respectively. The VO2 nanofibers, nanosheets, and nanorods show the linear response for glucose from 0.01–10, 0.625–15, and 0.625–10 mM, respectively. The proposed work will contribute to the nanozyme-based colorimetric assay. PMID:29068412
Samouëlian, Vanessa; Mechtouf, Nawel; Leblanc, Eric; Cardin, Guillaume B.; Lhotellier, Valérie; Querleu, Denis; Révillion, Françoise; Rodier, Francis
2018-01-01
Metastatic nodal involvement is a critical prognostic factor in uterine cervical cancer (UCC). To improve current methods of detecting UCC metastases in lymph nodes (LNs), we used quantitative PCR (qPCR) to assess mRNA expression of potential metastatic biomarkers. We found that expression of HPV16-E6, cytokeratin19 (CK19), and mucin1 (MUC1) is consistently upregulated in tumors and metastatic tissues, supporting a role for these genes in UCC progression. These putative biomarkers were able to predict the presence of histologically positive metastatic LNs with respective sensitivities and specificities of 82% and 99% (CK19), 76% and 95% (HPV16-E6), and 76% and 78% (MUC1). While the biomarkers failed to detect 1.7% to 2.2% of the histologically positive LNs when used individually, combining CK19 and HPV16-E6 enhanced sensitivity and specificity to 100% and 94%, respectively. To explore the sensitivity of qPCR-based detection of varying proportions of invading HPV16-positive UCC cells, we designed a LN metastasis model that achieved a fresh cell detection limit of 0.008% (1:12500 HPV16-positive to HPV16-negative cells), and a paraffin-embedded, formalin-fixed (PEFF) detection limit of 0.02% (1:5000 HPV16-positive to HPV16-negative cells), both of which are within the theoretical detection limit for micrometastasis. Thus, HPV E6/E7 oncogenes may be useful targets for the ultrasensitive detection of nodal involvements like micrometastases in fresh or archived tissue samples. Moreover, our results suggest that the biomarker combination of CK19/HPV-E6 could support a real-time intraoperative strategy for the detection of small, but potentially lethal, metastatic nodal involvements in fresh UCC tissues. PMID:29774091
Performance limitations of label-free sensors in molecular diagnosis using complex samples
NASA Astrophysics Data System (ADS)
Varma, Manoj
2016-03-01
Label-free biosensors promised a paradigm involving direct detection of biomarkers from complex samples such as serum without requiring multistep sample processing typical of labelled methods such as ELISA or immunofluorescence assays. Label-free sensors have witnessed decades of development with a veritable zoo of techniques available today exploiting a multitude of physical effects. It is appropriate now to critically assess whether label-free technologies have succeeded in delivering their promise with respect to diagnostic applications, particularly, ambitious goals such as early cancer detection using serum biomarkers, which require low limits of detection (LoD). Comparison of nearly 120 limits of detection (LoD) values reported by labelled and label-free sensing approaches over a wide range of detection techniques and target molecules in serum revealed that labeled techniques achieve 2-3 orders of magnitude better LoDs. Data from experiments where labelled and label-free assays were performed simultaneously using the same assay parameters also confirm that the LoD achieved by labelled techniques is 2 to 3 orders of magnitude better than that by label-free techniques. Furthermore, label-free techniques required significant signal amplification, for e.g. using nanoparticle conjugated secondary antibodies, to achieve LoDs comparable to labelled methods substantially deviating from the original "direct detection" paradigm. This finding has important implications on the practical limits of applying label-free detection methods for molecular diagnosis.
Tong, Rui; Zhou, Wei-Min; Liu, Xi-Jun; Wang, Yue; Lou, Yong-Liang; Tan, Wen-Jie
2013-04-01
To analyze the infection of human parvovirus B19, human bocavirus (HBoV) and human parvovirus 4 (PARV4) in blood samples among patients with liver disease in Nanjing by molecular detection. Nested PCR assays were designed and validated to detect B19, HBoV and PARV4, respectively. The assays were used to screen three parvoviruses in blood samples from 95 patients with different liver disease in Nanjing. The parvovirus infection was analyzed statistically. The detection limits were 10 copies of genomic DNA equivalents per reaction for each assays and the good specificity were observed. The frequency of B19 and HBoV were 2/95 (2.1%) and 9/95 (9.5%) in blood samples respectively. No PARV4 was detected. HBoV was detected in 3/5 patients with drug-induced hepatitis. Both B19 and HBoV infection were detected in blood from patients with liver disease.
Novel utilisation of a circular multi-reflection cell applied to materials ageing experiments
NASA Astrophysics Data System (ADS)
Knox, D. A.; King, A. K.; McNaghten, E. D.; Brooks, S. J.; Martin, P. A.; Pimblott, S. M.
2015-04-01
We report on the novel utilisation of a circular multi-reflection (CMR) cell applied to materials ageing experiments. This enabled trace gas detection within a narrow interfacial region located between two sample materials and remotely interrogated with near-infrared sources combined with fibre-optic coupling. Tunable diode laser absorption spectroscopy was used to detect water vapour and carbon dioxide at wavelengths near 1,358 and 2,004 nm, respectively, with corresponding detection limits of 7 and 1,139 ppm m Hz-0.5. The minimum detectable absorption was estimated to be 2.82 × 10-3 over a 1-s average. In addition, broadband absorption spectroscopy was carried out for the detection of acetic acid, using a super-luminescent light emitting diode centred around 1,430 nm. The 69 cm measurement pathlength was limited by poor manufacturing tolerances of the spherical CMR mirrors and the consequent difficulty of collecting all the cell output light.
Detection of Xeljanz enantiomers in diethyl amine active pharmaceutical ingredients and tablets.
Wang, Na-Na; Zhang, Dao-Lin; Jiang, Xin-Hui
2015-03-01
A high-performance liquid chromatography (HPLC) method was established to detect Xeljanz enantiomers in active pharmaceutical ingredients (APIs) and tablets. The separation was achieved on a Chiralpak IC column using a mobile phase of hexane-ethanol-diethylamine (65:35:0.1, v/v). The detection wavelength was 289 nm. The peak areas and the enantiomer concentrations in the range of 0.15-2.25 μg•mL(-1) were in high linearity, with correlation coefficients higher than 0.999. The recoveries were 86.44% at the concentrations of 7.5, 18.75, and 37.5 μg•mL(-1) . The limit of detection (LOD) and limit of quantification (LOQ) were 0.042 and 0.14 μg•mL(-1) , respectively. This HPLC method is suitable for detecting the enantiomers of Xeljanz in its APIs and tablets. © 2014 Wiley Periodicals, Inc.
Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence
2015-01-01
This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R (2) values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes.
Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence
2015-01-01
This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R 2 values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes. PMID:25785274
Direct sampling of chemical weapons in water by photoionization mass spectrometry.
Syage, Jack A; Cai, Sheng-Suan; Li, Jianwei; Evans, Matthew D
2006-05-01
The vulnerability of water supplies to toxic contamination calls for fast and effective means for screening water samples for multiple threats. We describe the use of photoionization (PI) mass spectrometry (MS) for high-speed, high-throughput screening and molecular identification of chemical weapons (CW) threats and other hazardous compounds. The screening technology can detect a wide range of compounds at subacute concentrations with no sample preparation and a sampling cycle time of approximately 45 s. The technology was tested with CW agents VX, GA, GB, GD, GF, HD, HN1, and HN3, in addition to riot agents and precursors. All are sensitively detected and give simple PI mass spectra dominated by the parent ion. The target application of the PI MS method is as a routine, real-time early warning system for CW agents and other hazardous compounds in air and in water. In this work, we also present comprehensive measurements for water analysis and report on the system detection limits, linearity, quantitation accuracy, and false positive (FP) and false negative rates for concentrations at subacute levels. The latter data are presented in the form of receiver operating characteristic curves of the form of detection probability P(D) versus FP probability P(FP). These measurements were made using the CW surrogate compounds, DMMP, DEMP, DEEP, and DIMP. Method detection limits (3sigma) obtained using a capillary injection method yielded 1, 6, 3, and 2 ng/mL, respectively. These results were obtained using 1-microL injections of water samples without any preparation, corresponding to mass detection limits of 1, 6, 3, and 2 pg, respectively. The linear range was about 3-4 decades and the dynamic range about 4-5 decades. The relative standard deviations were generally <10% at CW subacute concentrations levels.
Oloniniyi, Olamide K; Kurosaki, Yohei; Miyamoto, Hiroko; Takada, Ayato; Yasuda, Jiro
2017-08-01
Ebola virus disease (EVD), a highly virulent infectious disease caused by ebolaviruses, has a fatality rate of 25-90%. Without a licensed chemotherapeutic agent or vaccine for the treatment and prevention of EVD, control of outbreaks requires accurate and rapid diagnosis of cases. In this study, five sets of six oligonucleotide primers targeting the nucleoprotein gene were designed for specific identification of each of the five ebolavirus species using reverse transcription-loop mediated isothermal amplification (RT-LAMP) assay. The detection limits of the ebolavirus species-specific primer sets were evaluated using in vitro transcribed RNAs. The detection limit of species-specific RT-LAMP assays for Zaire ebolavirus, Sudan ebolavirus, Taï Forest ebolavirus, and Bundibugyo ebolavirus was 256 copies/reaction, while the detection limit for Reston ebolavirus was 64 copies/reaction, and the detection time for each of the RT-LAMP assays was 13.3±3.0, 19.8±4.6, 14.3±0.6, 16.1±4.7, and 19.8±2.4min (mean±SD), respectively. The sensitivity of the species-specific RT-LAMP assays were similar to that of the established RT-PCR and quantitative RT-PCR assays for diagnosis of EVD and are suitable for field or point-of-care diagnosis. The RT-LAMP assays were specific for the detection of the respective species of ebolavirus with no cross reaction with other species of ebolavirus and other viral hemorrhagic fever viruses such as Marburg virus, Lassa fever virus, and Dengue virus. The species-specific RT-LAMP assays developed in this study are rapid, sensitive, and specific and could be useful in case of an EVD outbreak. Copyright © 2017 Elsevier B.V. All rights reserved.
Šrámková, Ivana; Amorim, Célia G; Sklenářová, Hana; Montenegro, Maria C B M; Horstkotte, Burkhard; Araújo, Alberto N; Solich, Petr
2014-01-01
In this work, an application of an enzymatic reaction for the determination of the highly hydrophobic drug propofol in emulsion dosage form is presented. Emulsions represent a complex and therefore challenging matrix for analysis. Ethanol was used for breakage of a lipid emulsion, which enabled optical detection. A fully automated method based on Sequential Injection Analysis was developed, allowing propofol determination without the requirement of tedious sample pre-treatment. The method was based on spectrophotometric detection after the enzymatic oxidation catalysed by horseradish peroxidase and subsequent coupling with 4-aminoantipyrine leading to a coloured product with an absorbance maximum at 485 nm. This procedure was compared with a simple fluorimetric method, which was based on the direct selective fluorescence emission of propofol in ethanol at 347 nm. Both methods provide comparable validation parameters with linear working ranges of 0.005-0.100 mg mL(-1) and 0.004-0.243 mg mL(-1) for the spectrophotometric and fluorimetric methods, respectively. The detection and quantitation limits achieved with the spectrophotometric method were 0.0016 and 0.0053 mg mL(-1), respectively. The fluorimetric method provided the detection limit of 0.0013 mg mL(-1) and limit of quantitation of 0.0043 mg mL(-1). The RSD did not exceed 5% and 2% (n=10), correspondingly. A sample throughput of approx. 14 h(-1) for the spectrophotometric and 68 h(-1) for the fluorimetric detection was achieved. Both methods proved to be suitable for the determination of propofol in pharmaceutical formulation with average recovery values of 98.1 and 98.5%. © 2013 Elsevier B.V. All rights reserved.
Voltage tunable two-color superlattice infrared photodetectors
NASA Astrophysics Data System (ADS)
Majumdar, Amlan; Choi, Kwong-Kit; Reno, John L.; Tsui, Daniel C.
2004-11-01
We present the design and fabrication of voltage tunable two-color superlattice infrared photodetectors (SLIPs), where the detection wavelength switches from the long-wavelength infrared (LWIR) range to the mid-wavelength infrared (MWIR) range upon reversing the polarity of applied bias. The photoactive region of these detectors contains multiple periods of two distinct short-period SLs that are designed for MWIR and LWIR detection. The voltage tunable operation is achieved by using two types of thick blocking barriers between adjacent SLs - undoped barriers on one side for low energy electrons and heavily-doped layers on the other side for high energy electrons. We grew two SLIP structures by molecular beam epitaxy. The first one consists of two AlGaAs/GaAs SLs with the detection range switching from the 7-11 μm band to the 4-7 μm range on reversing the bias polarity. The background-limited temperature is 55 and 80 K for LWIR and MWIR detection, respectively. The second structure comprises of strained InGaAs/GaAs/AlGaAs SLs and AlGaAs/GaAs SLs. The detection range of this SLIP changes from the 8-12 μm band to the 3-5 μm band on switching the bias polarity. The background-limited temperature is 70 and 110 K for LWIR and MWIR detection, respectively. This SLIP is the first ever voltage tunable MWIR/LWIR detector with performance comparable to those of one-color quantum-well infrared detectors designed for the respective wavelength ranges. We also demonstrate that the corrugated light coupling scheme, which enables normal-incidence absorption, is suitable for the two-color SLIPs. Since these SLIPs are two-terminal devices, they can be used with the corrugated geometry for the production of low-cost large-area two-color focal plane arrays.
Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer.
Chang, Yanli; Xu, Jianjun; Zhang, Qingyun
2017-10-01
Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for the detection of urinary survivin levels and evaluate its application for the diagnosis of patients with bladder cancer. Horseradish peroxidase and biotin conjugates were used to label two different anti-survivin McAbs, respectively. The labeled antibodies combined with survivin to form a sandwiched immune complex. The streptavidin magnetic particles (MPs) served as the solid phase and the separator. The relevant parameters involved in the immunoassay, including the immunoassay reagents used and the physicochemical parameters were optimized. Then, urine samples from 130 patients with bladder cancer and 113 healthy controls were detected, and analyzed using the established method. The method was linear to 1,000 ng/ml survivin with a detection limit of 0.83 ng/ml. The intra- and inter-assay coefficients of variation were <8, and <11%, respectively. The concentration of diluted survivin and the dilution ratios gave a linear correlation of 0.9989. The results demonstrated that the urinary survivin levels in patients with bladder cancer were significantly higher (P<0.001) compared with that in healthy controls. At a survivin concentration of 2.0884 ng/ml, the sensitivity and specificity were 86.9 and 61.9%, respectively. Furthermore, the urinary survivin levels were positively correlated with metastatic stage, histological stage and recurrence (P<0.01). In conclusion, the present study preliminarily proposed a microplate magnetic CLIA for survivin detection and further evaluated the value of urinary survivin as a diagnostic marker for bladder cancer.
Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer
Chang, Yanli; Xu, Jianjun; Zhang, Qingyun
2017-01-01
Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for the detection of urinary survivin levels and evaluate its application for the diagnosis of patients with bladder cancer. Horseradish peroxidase and biotin conjugates were used to label two different anti-survivin McAbs, respectively. The labeled antibodies combined with survivin to form a sandwiched immune complex. The streptavidin magnetic particles (MPs) served as the solid phase and the separator. The relevant parameters involved in the immunoassay, including the immunoassay reagents used and the physicochemical parameters were optimized. Then, urine samples from 130 patients with bladder cancer and 113 healthy controls were detected, and analyzed using the established method. The method was linear to 1,000 ng/ml survivin with a detection limit of 0.83 ng/ml. The intra- and inter-assay coefficients of variation were <8, and <11%, respectively. The concentration of diluted survivin and the dilution ratios gave a linear correlation of 0.9989. The results demonstrated that the urinary survivin levels in patients with bladder cancer were significantly higher (P<0.001) compared with that in healthy controls. At a survivin concentration of 2.0884 ng/ml, the sensitivity and specificity were 86.9 and 61.9%, respectively. Furthermore, the urinary survivin levels were positively correlated with metastatic stage, histological stage and recurrence (P<0.01). In conclusion, the present study preliminarily proposed a microplate magnetic CLIA for survivin detection and further evaluated the value of urinary survivin as a diagnostic marker for bladder cancer. PMID:28943911
Pyen, Grace S.; Browner, Richard F.; Long, Stephen
1986-01-01
A fixed-size simplex has been used to determine the optimum conditions for the simultaneous determination of arsenic, selenium, and antimony by hydride generation and inductively coupled plasma emission spectrometry. The variables selected for the simplex were carrier gas flow rate, rf power, viewing height, and reagent conditions. The detection limit for selenium was comparable to the preoptimized case, but there were twofold and fourfold improvements in the detection limits for arsenic and antimony, respectively. Precision of the technique was assessed with the use of artificially prepared water samples.
Corbitt, A J; Bennion, N; Forsythe, S J
2000-06-01
Fourteen food residues, Escherichia coli O157:H7 and Staphylococcus aureus on stainless steel surfaces were detected using a combined assay with adenylate kinase as a cellular marker and ATP bioluminescence. The limit of sensitivity ranged from 0.02 to 708 microg for minced meat and broccoli, respectively. Both methods gave the same detection limit (105 cfu) for E. coli and Staph. aureus on stainless steel surfaces. The combined adenylate kinase-ATP assay is applicable to monitor the hygiene of work surfaces, especially those prone to contamination by meat and vegetable residues.
Davidson, Josy; dos Santos, Amelia Miyashiro N; Garcia, Kessey Maria B; Yi, Liu C; João, Priscila C; Miyoshi, Milton H; Goulart, Ana Lucia
2012-09-01
To analyse the accuracy and reproducibility of photogrammetry in detecting thoracic abnormalities in infants born prematurely. Cross-sectional study. The Premature Clinic at the Federal University of São Paolo. Fifty-eight infants born prematurely in their first year of life. Measurement of the manubrium/acromion/trapezius angle (degrees) and the deepest thoracic retraction (cm). Digitised photographs were analysed by two blinded physiotherapists using a computer program (SAPO; http://SAPO.incubadora.fapesp.br) to detect shoulder elevation and thoracic retraction. Physical examinations performed independently by two physiotherapists were used to assess the accuracy of the new tool. Thoracic alterations were detected in 39 (67%) and in 40 (69%) infants by Physiotherapists 1 and 2, respectively (kappa coefficient=0.80). Using a receiver operating characteristic curve, measurement of the manubrium/acromion/trapezius angle and the deepest thoracic retraction indicated accuracy of 0.79 and 0.91, respectively. For measurement of the manubrium/acromion/trapezius angle, the Bland and Altman limits of agreement were -6.22 to 7.22° [mean difference (d)=0.5] for repeated measures by one physiotherapist, and -5.29 to 5.79° (d=0.75) between two physiotherapists. For thoracic retraction, the intra-rater limits of agreement were -0.14 to 0.18cm (d=0.02) and the inter-rater limits of agreement were -0.20 to -0.17cm (d=0.02). SAPO provided an accurate and reliable tool for the detection of thoracic abnormalities in preterm infants. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Zhou, Yaoyu; Tang, Lin; Zeng, Guangming; Chen, Jun; Cai, Ye; Zhang, Yi; Yang, Guide; Liu, Yuanyuan; Zhang, Chen; Tang, Wangwang
2014-11-15
Herein, we reported here a promising biosensor by taking advantage of the unique ordered mesoporous carbon nitride material (MCN) to convert the recognition information into a detectable signal with enzyme firstly, which could realize the sensitive, especially, selective detection of catechol and phenol in compost bioremediation samples. The mechanism including the MCN based on electrochemical, biosensor assembly, enzyme immobilization, and enzyme kinetics (elucidating the lower detection limit, different linear range and sensitivity) was discussed in detail. Under optimal conditions, GCE/MCN/Tyr biosensor was evaluated by chronoamperometry measurements and the reduction current of phenol and catechol was proportional to their concentration in the range of 5.00 × 10(-8)-9.50 × 10(-6)M and 5.00 × 10(-8)-1.25 × 10(-5)M with a correlation coefficient of 0.9991 and 0.9881, respectively. The detection limits of catechol and phenol were 10.24 nM and 15.00 nM (S/N=3), respectively. Besides, the data obtained from interference experiments indicated that the biosensor had good specificity. All the results showed that this material is suitable for load enzyme and applied to the biosensor due to the proposed biosensor exhibited improved analytical performances in terms of the detection limit and specificity, provided a powerful tool for rapid, sensitive, especially, selective monitoring of catechol and phenol simultaneously. Moreover, the obtained results may open the way to other MCN-enzyme applications in the environmental field. Copyright © 2014 Elsevier B.V. All rights reserved.
Ventricular repolarization variability for hypoglycemia detection.
Ling, Steve; Nguyen, H T
2011-01-01
Hypoglycemia is the most acute and common complication of Type 1 diabetes and is a limiting factor in a glycemic management of diabetes. In this paper, two main contributions are presented; firstly, ventricular repolarization variabilities are introduced for hypoglycemia detection, and secondly, a swarm-based support vector machine (SVM) algorithm with the inputs of the repolarization variabilities is developed to detect hypoglycemia. By using the algorithm and including several repolarization variabilities as inputs, the best hypoglycemia detection performance is found with sensitivity and specificity of 82.14% and 60.19%, respectively.
Gong, Shuguo; Liang, Yong; Tang, Liyun; Huang, Ping; Dai, Yunhui
2017-07-08
A high performance liquid chromatography with fluorescence detection (HPLC-FLD) method was developed for the simultaneous determination of formaldehyde and acetaldehyde in packaging paper by dansylhydrazine (DNSH) derivatization. The samples were extracted by derivatization reagent for 30 min, and derived for 24 h. After purifying treatment with a PSA/C18 cartridge, a Diamonsil ® C18 column (150 mm×4.6 mm, 5 μ m) was used as stationary phase for separation, the mixtures of acetic acid aqueous solution (pH 2.55)-acetonitrile were used as mobile phases by gradient elution, and the excitation and emission wavelengths were 330 nm and 484 nm, respectively. The results showed that the recoveries of formaldehyde and acetaldehyde spiked in the samples were 81.64%-106.78%, and the relative standard deviations (RSDs) were 2.02%-5.53% ( n =5). The limits of detection of formaldehyde and acetaldehyde were 19.2 μ g/kg and 20.7 μ g/kg, respectively. The limits of quantification of formaldehyde and acetaldehyde were 63.9 μ g/kg and 69.1 μ g/kg, respectively. The method is simple, sensitive and reproducible. It provides a basic approach for the determination of trace formaldehyde and acetaldehyde.
Using Public Network Infrastructures for UAV Remote Sensing in Civilian Security Operations
2011-03-01
leveraging public wireless communication networks for UAV-based sensor networks with respect to existing constraints and user requirements...Detection with an Autonomous Micro UAV Mesh Network . In the near future police departments, fire brigades and other homeland security ...UAV-based sensor networks with respect to existing constraints and user requirements. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION
Li, Di; Yang, Xiao-Lu; Xiao, Bao-Lin; Geng, Fang-Yong; Hong, Jun; Sheibani, Nader; Moosavi-Movahedi, Ali Akbar
2017-01-01
A new electrochemical sensor based on a Nafion, aminated reduced graphene oxide and chitosan functional membrane-modified glassy carbon electrode was proposed for the simultaneous detection of adenine and guanine. Fourier transform-infrared spectrometry (FTIR), transmission electron microscopy (TEM), and electrochemical methods were utilized for the additional characterization of the membrane materials. The prepared electrode was utilized for the detection of guanine (G) and adenine (A). The anodic peak currents to G and A were linear in the concentrations ranging from 0.1 to 120 μM and 0.2 to 110 μM, respectively. The detection limits were found to be 0.1 μM and 0.2 μM, respectively. Moreover, the modified electrode could also be used to determine G and A in calf thymus DNA. PMID:28718793
Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P
2012-01-01
Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ(9)-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ(9)-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ(9)-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ(9)-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis.
Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P.
2012-01-01
Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ9-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ9-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ9-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ9-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis. PMID:22567573
Juhel-Gaugain, M; Anger, B; Laurentie, M
1999-01-01
A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of tilmicosin, tylosin, spiramycin, and its major metabolite neospiramycin was developed that is suitable for porcine, bovine, and poultry muscles. Macrolide residues were extracted from muscle with acetonitrile, fat was removed by liquid-liquid extraction with isooctane, and the extract was then cleaned on Bond Elut C18 cartridges. The HPLC separation was performed on an Inertsil ODS3 C18 column (150 x 4 mm) with 0.05% trifluoroacetic acid-acetonitrile in a gradient mode. Two different chromatographic gradients were used for tilmicosin-tylosin and spiramycin-neospiramycin, and the detection wavelengths were 287 and 232 nm, respectively. The method was validated from 1/2 the maximum residue limit (MRL) to 4 times the MRL with pork muscle samples. Mean recoveries were 60, 63.5, 51, and 42% for tilmicosin, tylosin, spiramycin, and neospiramycin, respectively. The detection limits are 15 micrograms/kg for tilmicosin and tylosin, 30 micrograms/kg for spiramycin, and 25 micrograms/kg for neospiramycin. Linearity, precision, and accuracy of the method were also tested.
Development of an enzyme-linked immunosorbent assay for the detection of dicamba.
Clegg, B S; Stephenson, G R; Hall, J C
2001-05-01
A competitive indirect enzyme-linked immunosorbent assay (CI-ELISA) was developed to quantitate the herbicide dicamba (3,6-dichloro-2-methoxybenzoic acid) in water. The CI-ELISA has a detection limit of 2.3 microg L(-1) and a linear working range of 10--10000 microg L(-1) with an IC(50) value of 195 microg L(-1). The dicamba polyclonal antisera did not cross-react with a number of other herbicides tested but did cross-react with a dicamba metabolite, 5-hydroxydicamba, and structurally related chlorobenzoic acids. The assay was used to estimate quantitatively dicamba concentrations in water samples. Water samples were analyzed directly, and no sample preparation was required. To improve detection limits, a C(18) (reversed phase) column concentration step was devised prior to analysis, and the detection limits were increased by at least by 10-fold. After the sample preconcentration, the detection limit, IC(50), and linear working range were 0.23, 19.5, and 5-200 microg L(-1), respectively. The CI-ELISA estimations in water correlated well with those from gas chromatography-mass spectrometry (GC-MS) analysis (r(2) = 0.9991). This assay contributes to reducing laboratory costs associated with the conventional GC-MS residue analysis techniques for the quantitation of dicamba in water.
Zhang, Jiali; Shi, Lei; Zhu, Song; Xu, Xinbiao; Zhang, Xinliang
2016-05-11
A highly sensitive refractive index sensor with low detection limit based on an asymmetric optical microfiber coupler is proposed. It is composed of a silica optical microfiber and an As₂Se₃ optical microfiber. Due to the asymmetry of the microfiber materials, a single-notch transmission spectrum is demonstrated by the large refractive index difference between the two optical microfibers. Compared with the symmetric coupler, the bandwidth of the asymmetric structure is over one order of magnitude narrower than that of the former. Therefore, the asymmetric optical microfiber coupler based sensor can reach over one order of magnitude smaller detection limit, which is defined as the minimal detectable refractive index change caused by the surrounding analyte. With the advantage of large evanescent field, the results also show that a sensitivity of up to 3212 nm per refractive index unit with a bandwidth of 12 nm is achieved with the asymmetric optical microfiber coupler. Furthermore, a maximum sensitivity of 4549 nm per refractive index unit can be reached while the radii of the silica optical microfiber and As₂Se₃ optical microfiber are 0.5 μm and a 0.128 μm, respectively. This sensor component may have important potential for low detection-limit physical and biochemical sensing applications.
Liang, Jiajie; Liu, Hongwu; Huang, Caihong; Yao, Cuize; Fu, Qiangqiang; Li, Xiuqing; Cao, Donglin; Luo, Zhi; Tang, Yong
2015-06-02
Lowering the detection limit is critical to the design of bioassays required for medical diagnostics, environmental monitoring, and food safety regulations. The current sensitivity of standard color-based analyte detection limits the further use of enzyme-linked immunosorbent assays (ELISAs) in research and clinical diagnoses. Here, we demonstrate a novel method that uses the Raman signal as the signal-generating system of an ELISA and combines surface-enhanced Raman scattering (SERS) with silver nanoparticles aggregation for ultrasensitive analyte detection. The enzyme label of the ELISA controls the dissolution of Raman reporter-labeled silver nanoparticles through hydrogen peroxide and generates a strong Raman signal when the analyte is present. Using this assay, prostate-specific antigen (PSA) and the adrenal stimulant ractopamine (Rac) were detected in whole serum and urine at the ultralow concentrations of 10(-9) and 10(-6) ng/mL, respectively. The methodology proposed here could potentially be applied to other molecules detection as well as PSA and Rac.
2002-01-01
compared to culture.70,72 Use of PCR to detect GC has yielded sensitivities between 92-100% and specificities ranging from 96-99% on endocervical...specimen.73,74 With use of urine specimens, PCR has yielded sensitivities ranging from 65 to 92% and 96-99% respectively, for GC detection .74...21 An important limitation of PCR and LCR is that the tests may detect CT or GC nucleic acid remaining after therapy has been administered
Lee, Seung-Hyun; Joung, Migyo; Yoon, Sejoung; Choi, Kyoungjin; Park, Woo-Yoon; Yu, Jae-Ran
2010-12-01
Recently, emerging waterborne protozoa, such as microsporidia, Cyclospora, and Cryptosporidium, have become a challenge to human health worldwide. Rapid, simple, and economical detection methods for these major waterborne protozoa in environmental and clinical samples are necessary to control infection and improve public health. In the present study, we developed a multiplex PCR test that is able to detect all these 3 major waterborne protozoa at the same time. Detection limits of the multiplex PCR method ranged from 10(1) to 10(2) oocysts or spores. The primers for microsporidia or Cryptosporidium used in this study can detect both Enterocytozoon bieneusi and Encephalitozoon intestinalis, or both Cryptosporidium hominis and Cryptosporidium parvum, respectively. Restriction enzyme digestion of PCR products with BsaBI or BsiEI makes it possible to distinguish the 2 species of microsporidia or Cryptosporidium, respectively. This simple, rapid, and cost-effective multiplex PCR method will be useful for detecting outbreaks or sporadic cases of waterborne protozoa infections.
Nanoplatforms for Detection, Remediation and Protection Against Chem-Bio Warfare
NASA Astrophysics Data System (ADS)
Denkbaş, E. B.; Bayram, C.; Kavaz, D.; Çirak, T.; Demirbilek, M.
Chemical and biological substances have been used as warfare agents by terrorists by varying degree of sophistication. It is critical that these agents be detected in real-time with high level of sensitively, specificity, and accuracy. Many different types of techniques and systems have been developed to detect these agents. But there are some limitations in these conventional techniques and systems. Limitations include the collection, handling and sampling procedures, detection limits, sample transfer, expensive equipment, personnel training, and detection materials. Due to the unique properties such as quantum effect, very high surface/volume ratio, enhanced surface reactivity, conductivity, electrical and magnetic properties of the nanomaterials offer great opportunity to develop very fast, sensitive, accurate and cost effective detection techniques and systems to detect chemical and biological (chem.-bio) warfare agents. Furthermore, surface modification of the materials is very easy and effective way to get functional or smart surfaces to be used as nano-biosensor platform. In that respect many different types of nanomaterials have been developed and used for the detection, remediation and protection, such as gold and silver nanoparticles, quantum dots, Nano chips and arrays, fluorescent polymeric and magnetic nanoparticles, fiber optic and cantilever based nanobiosensors, nanofibrillar nanostructures etc. This study summarizes preparation and characterization of nanotechnology based approaches for the detection of and remediation and protection against chem.-bio warfare agents.
Ulu, Sevgi Tatar
2012-01-01
A sensitive spectrofluorimetric method was developed for the determination of tizanidine in human plasma, urine and pharmaceutical preparations. The method is based on reaction of tizanidine with 1-dimethylaminonaphthalene-5-sulphonyl chloride (dansyl chloride) in an alkaline medium to form a highly fluorescent derivative that was measured at 511 nm after excitation at 383 nm. The different experimental parameters affecting the fluorescence intensity of tizanidine was carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges 50-500 and 20-300 ng/mL for plasma and urine, respectively, detection limits of 1.81 and 0.54 ng/mL and quantification limits of 5.43 and 1.62 ng/mL for plasma and urine, respectively. The method presents good performance in terms of linearity, detection and quantification limits, precision, accuracy and specificity. The proposed method was successfully applied for the determination of tizanidine in pharmaceutical preparations. The results obtained were compared with a reference method, using t- and F-tests. Copyright © 2011 John Wiley & Sons, Ltd.
Lopa, Nasrin Siraj; Rahman, Md Mahbubur; Jang, Hohyoun; Sutradhar, Sabuj Chandra; Ahmed, Faiz; Ryu, Taewook; Kim, Whangi
2017-12-06
2,4-Dinitrophenylhydrazine (DNPH) was electropolymerized on the surface of an anodized glassy carbon electrode by cyclic voltammetry. The anodized electrode has a highly electroactive surface due to the creation of chemically functionalized graphitic nanoparticles, and this facilitates the formation of poly-DNPH via radical polymerization. Poly-DNPH displays excellent redox activity due to the presence of nitro groups on its backbone. These catalyze the electro-oxidation of hydroquinone (HQ) and catechol (CT). The peak-to-peak separation is around 109 mV, while a bare GCE cannot resolve the peaks (located at 165 and 274 mV vs. Ag/AgCl). Sensitivity is also enhanced to ∼1.20 and 1.19 μA·cm -2 ·μM -1 , respectively. The sensor has a linear response that covers the 20-250 μM concentration range for both HQ and CT, with 0.75 and 0.76 μM detection limits, respectively, at simultaneous detection. Commonly present species do not interfere. Graphical abstract A novel conducting poly(2,4-dinitrophenylhydrazine)-modified anodized glassy carbon electrode (pDNPH/AGCE) was developed by electrochemical method. The electro-catalytic activity of pDNPH/AGCE sensor was investigated for the selective and simultaneous electrochemical detection of hydroquinone (HQ) and catechol (CT), which revealed high sensitivities and low detection limits with excellent stability.
West, Danielle M; Mu, Ruipu; Gamagedara, Sanjeewa; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Burken, Joel G; Shi, Honglan
2015-06-01
Perchlorate and bromate occurrence in drinking water causes health concerns due to their effects on thyroid function and carcinogenicity, respectively. The purpose of this study was threefold: (1) to advance a sensitive method for simultaneous rapid detection of perchlorate and bromate in drinking water system, (2) to systematically study the occurrence of these two contaminants in Missouri drinking water treatment systems, and (3) to examine effective sorbents for minimizing perchlorate in drinking water. A rapid high-performance ion exchange chromatography-tandem mass spectrometry (HPIC-MS/MS) method was advanced for simultaneous detection of perchlorate and bromate in drinking water. The HPIC-MS/MS method was rapid, required no preconcentration of the water samples, and had detection limits for perchlorate and bromate of 0.04 and 0.01 μg/L, respectively. The method was applied to determine perchlorate and bromate concentrations in total of 23 selected Missouri drinking water treatment systems during differing seasons. The water systems selected include different source waters: groundwater, lake water, river water, and groundwater influenced by surface water. The concentrations of perchlorate and bromate were lower than or near to method detection limits in most of the drinking water samples monitored. The removal of perchlorate by various adsorbents was studied. A cationic organoclay (TC-99) exhibited effective removal of perchlorate from drinking water matrices.
A gold immunochromatographic assay for the rapid and simultaneous detection of fifteen β-lactams
NASA Astrophysics Data System (ADS)
Chen, Yanni; Wang, Yongwei; Liu, Liqiang; Wu, Xiaoling; Xu, Liguang; Kuang, Hua; Li, Aike; Xu, Chuanlai
2015-10-01
A novel gold immunochromatographic assay (GICA) based on anti-β-lactam receptors was innovatively developed that successfully allowed rapid and simultaneous detection of fifteen β-lactams in milk samples in 5-10 minutes. By replacing the antibodies used in traditional GICA with anti-β-lactam receptors, the difficulty in producing broad specific antibodies against β-lactams was overcome. Conjugates of ampicillin with BSA and goat anti-mouse immunoglobulin (IgG) were immobilized onto the test and control lines on the nitrocellulose membrane, respectively. Since goat anti-mouse IgG does not combine with receptors, negative serum from mice labelled with gold nanoparticles (GNP) was mixed with GNP-labelled receptors. Results were obtained within 20 min using a paper-based sensor. The utility of the assay was confirmed by the analysis of milk samples. The limits of detection (LOD) for amoxicillin, ampicillin, penicillin G, penicillin V, cloxacillin, dicloxacillin, nafcillin, oxacillin, cefaclor, ceftezole, cefotaxime, ceftiofur, cefoperazone, cefathiamidine, and cefepime were 0.25, 0.5, 0.5, 0.5, 1, 5, 5, 10, 25, 10, 100, 10, 5, 5, and 2 ng mL-1, respectively, which satisfies the maximum residue limits (MRL) set by the European Union (EU). In conclusion, our newly developed GICA-based anti-β-lactam receptor assay provides a rapid and effective method for one-site detection of multiple β-lactams in milk samples.A novel gold immunochromatographic assay (GICA) based on anti-β-lactam receptors was innovatively developed that successfully allowed rapid and simultaneous detection of fifteen β-lactams in milk samples in 5-10 minutes. By replacing the antibodies used in traditional GICA with anti-β-lactam receptors, the difficulty in producing broad specific antibodies against β-lactams was overcome. Conjugates of ampicillin with BSA and goat anti-mouse immunoglobulin (IgG) were immobilized onto the test and control lines on the nitrocellulose membrane, respectively. Since goat anti-mouse IgG does not combine with receptors, negative serum from mice labelled with gold nanoparticles (GNP) was mixed with GNP-labelled receptors. Results were obtained within 20 min using a paper-based sensor. The utility of the assay was confirmed by the analysis of milk samples. The limits of detection (LOD) for amoxicillin, ampicillin, penicillin G, penicillin V, cloxacillin, dicloxacillin, nafcillin, oxacillin, cefaclor, ceftezole, cefotaxime, ceftiofur, cefoperazone, cefathiamidine, and cefepime were 0.25, 0.5, 0.5, 0.5, 1, 5, 5, 10, 25, 10, 100, 10, 5, 5, and 2 ng mL-1, respectively, which satisfies the maximum residue limits (MRL) set by the European Union (EU). In conclusion, our newly developed GICA-based anti-β-lactam receptor assay provides a rapid and effective method for one-site detection of multiple β-lactams in milk samples. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr04987c
Yueh, Fang-Yu; Sharma, Ramesh C; Singh, Jagdish P; Zhang, Hansheng; Spencer, William A
2002-11-01
The analytical figure of merit of the potential of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of trace element in liquid. LIBS data of Mg, Cr, Mn, and Re were studied. Various optical geometries, which produce the laser spark in and at the liquid sample, were tested. The calibration curves for Mg, Cr, Mn, and Re were obtained at the optimized experimental conditions with bulk liquid and in liquid jet. It was found that measurements using a liquid jet provide better detection limits than bulk liquid measurements. The limits of detection (LOD) of Mg, Cr, Mn, and Re in the present liquid jet measurement are found to be 0.1, 0.4, 0.7, and 8 ppm, respectively. The LOD of Mg using Mg 279.55 nm was compared with the values found in other liquid work.
SERS-based pesticide detection by using nanofinger sensors
NASA Astrophysics Data System (ADS)
Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong
2015-01-01
Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.
Guillo, Christelle; Ferrance, Jerome P; Landers, James P
2006-04-28
Highly selective and sensitive assays are required for detection and quantitation of the small masses of DNA typically encountered in clinical and forensic settings. High detection sensitivity is achieved using fluorescent labeling dyes and detection techniques such as spectrofluorometers, microplate readers and cytometers. This work describes the use of a laser-induced fluorescence (LIF) detector in conjunction with a commercial capillary electrophoresis instrument for DNA quantitation. PicoGreen and YO-PRO-1, two fluorescent DNA labeling dyes, were used to assess the potential of the system for routine DNA analysis. Linearity, reproducibility, sensitivity, limits of detection and quantitation, and sample stability were examined for the two assays. The LIF detector response was found to be linear (R2 > 0.999) and reproducible (RSD < 9%) in both cases. The PicoGreen assay displayed lower limits of detection and quantitation (20 pg and 60 pg, respectively) than the YO-PRO-1 assay (60 pg and 260 pg, respectively). Although a small variation in fluorescence was observed for the DNA/dye complexes over time, quantitation was not significantly affected and the solutions were found to be relatively stable for 80 min. The advantages of the technique include a 4- to 40-fold reduction in the volume of sample required compared to traditional assays, a 2- to 20-fold reduction in the volume of reagents consumed, fast and automated analysis, and low cost (no specific instrumentation required).
Wang, Jiamian; Song, Jie; Wang, Xiuyun; Wu, Shuo; Zhao, Yanqiu; Luo, Pinchen; Meng, Changgong
2016-12-01
A label-free ratiometric fluorescence aptasensor has been developed for the rapid and sensitive detection of cocaine in complex biofluids. The fluorescent aptasensor is composed of a non-labeled GC-38 cocaine aptamer which serves as a basic sensing unit and two fluorophores, 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND) and SYBR Green I (SGI) which serves as a signal reporter and a build-in reference, respectively. The detection principle is based on a specific cocaine mediated ATMND displacement reaction and the corresponding change in the fluorescence ratio of ATMND to SGI. Due to the high affinity of the non-labeled aptamer, the good precision originated from the ratiometric method, and the good fluorescence quantum yield of the fluorophore, the aptasensor shows good analytical performance with respect to cocaine detection. Under optimal conditions, the aptasensor shows a linear range of 0.10-10μM and a low limit of detection of 56nM, with a fast response of 20s. The low limit of detection is comparable to most of the fluorescent aptasensors with signal amplification strategies and much lower than all of the unamplified cocaine aptasensors. Practical sample analysis in a series of complex biofluids, including urine, saliva and serum, also indicates the good precision, stability, and high sensitivity of the aptasensor, which may have great potential for the point-of-care screening of cocaine in complex biofluids. Copyright © 2016 Elsevier B.V. All rights reserved.
Asymmetric split-ring resonator-based biosensor for detection of label-free stress biomarkers
NASA Astrophysics Data System (ADS)
Lee, Hee-Jo; Lee, Jung-Hyun; Choi, Suji; Jang, Ik-Soon; Choi, Jong-Soon; Jung, Hyo-Il
2013-07-01
In this paper, an asymmetric split-ring resonator, metamaterial element, is presented as a biosensing transducer for detection of highly sensitive and label-free stress biomarkers. In particular, the two biomarkers, cortisol and α-amylase, are used for evaluating the sensitivity of the proposed biosensor. In case of cortisol detection, the competitive reaction between cortisol-bovine serum albumin and free cortisol is employed, while alpha-amylase is directly detected by its antigen-antibody reaction. From the experimental results, we find that the limit of detection and sensitivity of the proposed sensing device are about 1 ng/ml and 1.155 MHz/ng ml-1, respectively.
da Costa, José Luiz; da Matta Chasin, Alice Aparecida
2004-11-05
This paper describes the development and validation of analytical methodology for the determination of the use of MDMA, MDEA and MDA in urine. After a simple liquid extraction, the analyses were carried out on a high performance liquid chromatography (HPLC) in an octadecyl column, with fluorescence detection. The mobile phase using a sodium dodecyl sulfate ion-pairing reagent allows good separation and efficiency. The method showed good linearity and precision. Recovery was between 85 and 102% and detection limits were 10, 15 and 20 ng/ml for MDA, MDMA and MDEA, respectively. No interfering substances were detected with fluorescence detection.
One-step liquid-liquid extraction of cocaine from urine samples for gas chromatographic analysis.
Farina, Marcelo; Yonamine, Maurício; Silva, Ovandir A
2002-07-17
An improved technique for cocaine extraction from urine samples for gas chromatographic (GC) analysis is described. Employing a simple liquid-liquid extraction (LLE) of cocaine with a mixture of ethyl ether:isopropanol (9:1) the method presents a mean recovery of 74.49%. Limit of detection (LOD) and limit of quantification (LOQ) were 5 and 20 ng/ml, respectively. The method is highly precise (coefficient of variation (CV) <8%) and linear from 20 to 2000 ng/ml. It can he applied to detect the presence of cocaine in urine as a marker of its recent use in drug abuse treatment protocols.
Simple colorimetric detection of doxycycline and oxytetracycline using unmodified gold nanoparticles
NASA Astrophysics Data System (ADS)
Li, Jie; Fan, Shumin; Li, Zhigang; Xie, Yuanzhe; Wang, Rui; Ge, Baoyu; Wu, Jing; Wang, Ruiyong
2014-08-01
The interaction between tetracycline antibiotics and gold nanoparticles was studied. With citrate-coated gold nanoparticles as colorimetric probe, a simple and rapid detection method for doxycycline and oxytetracycline has been developed. This method relies on the distance-dependent optical properties of gold nanoparticles. In weakly acidic buffer medium, doxycycline and oxytetracycline could rapidly induce the aggregation of gold nanoparticles, resulting in red-to-blue (or purple) colour change. The experimental parameters were optimized with regard to pH, the concentration of the gold nanoparticles and the reaction time. Under optimal experimental conditions, the linear range of the colorimetric sensor for doxycycline/oxytetracycline was 0.06-0.66 and 0.59-8.85 μg mL-1, respectively. The corresponding limit of detection for doxycycline and oxytetracycline was 0.0086 and 0.0838 μg mL-1, respectively. This assay was sensitive, selective, simple and readily used to detect tetracycline antibiotics in food products.
A STATISTICAL SURVEY OF DIOXIN-LIKE COMPOUNDS IN ...
The USEPA and the USDA completed the first statistically designed survey of the occurrence and concentration of dibenzo-p-dioxins (CDDs), dibenzofurans (CDFs), and coplanar polychlorinated biphenyls (PCBs) in the fat of beef animals raised for human consumption in the United States. Back fat was sampled from 63 carcasses at federally inspected slaughter establishments nationwide. The sample design called for sampling beef animal classes in proportion to national annual slaughter statistics. All samples were analyzed using a modification of EPA method 1613, using isotope dilution, High Resolution GC/MS to determine the rate of occurrence of 2,3,7,8-substituted CDDs/CDFs/PCBs. The method detection limits ranged from 0.05 ng/kg for TCDD to 3 ng/kg for OCDD. The results of this survey showed a mean concentration (reported as I-TEQ, lipid adjusted) in U.S. beef animals of 0.35 ng/kg and 0.89 ng/kg for CDD/CDF TEQs when either non-detects are treated as 0 value or assigned a value of 1/2 the detection limit, respectively, and 0.51 ng/kg for coplanar PCB TEQs at both non-detect equal 0 and 1/2 detection limit. journal article
SAMPLING AND ANALYSIS OF MERCURY IN CRUDE OIL
Sampling and analytical procedures used to determine total mercury content in crude oils were examined. Three analytical methods were compared with respect to accuracy, precision and detection limit. The combustion method and a commercial extraction method were found adequate to...
Shah, Umang; Patel, Shraddha; Raval, Manan
2018-01-01
High performance liquid chromatography is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect any drug-related impurities that may be introduced during synthesis. A simple, economic, selective, precise, and stability-indicating HPLC method has been developed and validated for analysis of Rifampicin (RIFA) and Piperine (PIPE) in bulk drug and in the formulation. Reversed-phase chromatography was performed on a C18 column with Buffer (Potassium Dihydrogen Orthophosphate) pH 6.5 and Acetonitrile, 30:70), (%, v/v), as mobile phase at a flow rate of 1 mL min-1. The detection was performed at 341 nm and sharp peaks were obtained for RIFA and PIPE at retention time of 3.3 ± 0.01 min and 5.9 ± 0.01 min, respectively. The detection limits were found to be 2.385 ng/ml and 0.107 ng/ml and quantification limits were found to be 7.228ng/ml and 0.325ng/ml for RIFA and PIPE, respectively. The method was validated for accuracy, precision, reproducibility, specificity, robustness, and detection and quantification limits, in accordance with ICH guidelines. Stress study was performed on RIFA and PIPE and it was found that these degraded sufficiently in all applied chemical and physical conditions. Thus, the developed RP-HPLC method was found to be suitable for the determination of both the drugs in bulk as well as stability samples of capsule containing various excipients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Ellis, Jenny L; Conklin, Sean D; Gallawa, Christina M; Kubachka, Kevin M; Young, Andrea R; Creed, Patricia A; Caruso, Joseph A; Creed, John T
2008-04-01
The simultaneous detection of arsenic and sulfur in thioarsenicals was achieved using xenon-based collision-cell inductively coupled plasma (ICP) mass spectrometry (MS) in combination with high-performance liquid chromatography. In an attempt to minimize the (16)O(16)O(+) interference at m/z 32, both sample introduction and collision-cell experimental parameters were optimized. Low flow rates (0.25 mL/min) and a high methanol concentration (8%) in the mobile phase produced a fourfold decrease in the m/z 32 background. A plasma sampling depth change from 3 to 7 mm produced a twofold decrease in background at m/z 32, with a corresponding fourfold increase in the signal associated with a high ionization surrogate for sulfur. The quadrupole bias and the octopole bias were used as a kinetic energy discriminator between background and analyte ions, but a variety of tuning conditions produced similar (less than twofold change) detection limits for sulfur ((32)S). A 34-fold improvement in the (32)S detection limit was achieved using xenon instead of helium as a collision gas. The optimized xenon-based collision cell ICP mass spectrometer was then used with electrospray ionization MS to provide elemental and molecular-based information for the analysis of a fortified sample of NIST freeze-dried urine. The 3sigma detection limits, based on peak height for dimethylthioarsinic acid (DMTA) and trimethylarsine sulfide (TMAS), were 15 and 12 ng/g, respectively. Finally, the peak area reproducibilities (percentage relative standard deviation) of a 5-ppm fortified sample of NIST freeze dried urine for DMTA and TMAS were 7.4 and 5.4%, respectively.
He, Xiaoqin; Xi, Cunxian; Tang, Bobin; Wang, Guomin; Chen, Dongdong; Peng, Tao; Mu, Zhaode
2014-01-01
A novel analytical method employing solid-phase extraction (SPE) coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 30 hormones in anti-ageing functional foods (capsules, powders and tablets). The analytes were extracted with acetic acid-acetonitrile (1-99 v/v), methanol and acetone, respectively. The extract was purified using a combined column, followed by analyte detection with electrospray ionisation in positive- or negative-ion modes. The results indicated that the 30 compounds had good linear correlations in the range of 1-1000 μg kg⁻¹, and the correlation coefficients were above 0.99. The limits of detection (LOD) and limits of quantification (LOQ) were 0.03-2 and 0.1-5 μg kg⁻¹, respectively. The average recovery of 30 compounds at the three spiked levels varied from 74.7% to 124.1%, and the relative standard deviation (RSD) was 2.4-15.0%. This method was applied to the analysis of hormones in 14 real samples of which seven hormones (such as estrone, dienestrol) were detected in four samples, but the remainder of the hormones were not detected. The developed method is sensitive, efficient, reliable and applicable to real samples.
Ulu, Sevgi Tatar; Tuncel, Muzaffer
2012-04-01
A novel precolumn derivatization reversed-phase high-performance liquid chromatography method with fluorescence detection is described for the determination of ranitidine in human plasma. The method was based on the reaction of ranitidine with 4-fluoro-7-nitrobenzo-2-oxa-1,3-diazole forming yellow colored fluorescent product. The separation was achieved on a C(18) column using methanol-water (60:40, v/v) mobile phase. Fluorescence detection was used at the excitation and emission of 458 and 521 nm, respectively. Lisinopril was utilized as an internal standard. The flow rate was 1.2 mL/min. Ranitidine and lisinopril appeared at 3.24 and 2.25 min, respectively. The method was validated for system suitability, precision, accuracy, linearity, limit of detection, limit of quantification, recovery and robustness. Intra- and inter-day precisions of the assays were in the range of 0.01-0.44%. The assay was linear over the concentration range of 50-2000 ng/mL. The mean recovery was determined to be 96.40 ± 0.02%. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (150 mg) of ranitidine. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Sam, Soya S; Caliendo, Angela M; Ingersoll, Jessica; Abdul-Ali, Deborah; Kraft, Colleen S
Timely and precise laboratory diagnosis of Herpes simplex viruses (HSV) is required to guide clinical management. The study evaluated limit of detection (LOD) and performance characteristics of the Aptima HSV 1 & 2 assay in comparison to four assays. The multi-center study compared qualitative detection of HSV-1 and 2 by the Aptima HSV-1 and 2 assay (Hologic) to ELVIS culture, Lyra Direct (Quidel), AmpliVue (Quidel) and a laboratory developed test (LDT). LOD was performed using VTM and STM diluted viral concentrations and clinical performance was evaluated using 505 swab specimens. The Aptima LOD studies performed showed a lower detection limit for STM specimens as 1450 copies/mL and 430 copies/mL for HSV1 and HSV-2 respectively; the LOD for VTM specimens was 9370 copies/mL and 8045 copies/mL for HSV-1 and HSV-2 respectively. When the assays were analyzed based on the positive consensus result established the Aptima had 95% of percent positive agreement (PPA) and 100% negative percent agreement (NPA) for the HSV-1. For the HSV-2, the PPA and NPA for Aptima were 96% and 100% respectively. AmpliVue had 1.8% invalid rate, while Lyra had no invalid results but an inhibition rate of 0.8%. Aptima and LDT did not have any invalid or inhibited results. The results indicate that the Aptima HSV-1 & 2 assay is sensitive and the performance characteristics of the Aptima assay is comparable to the assays analyzed for the detection and differentiation of HSV-1 and 2 from cutaneous and mucocutaneous lesions. Copyright © 2017 Elsevier B.V. All rights reserved.
Borgmästars, Emmy; Jazi, Mehrdad Mousavi; Persson, Sofia; Jansson, Linda; Rådström, Peter; Simonsson, Magnus; Hedman, Johannes; Eriksson, Ronnie
2017-12-01
Quantitative reverse transcriptase polymerase chain reaction (RT-qPCR) detection of waterborne RNA viruses generally requires concentration of large water volumes due to low virus levels. A common approach is to use dead-end ultrafiltration followed by precipitation with polyethylene glycol. However, this procedure often leads to the co-concentration of PCR inhibitors that impairs the limit of detection and causes false-negative results. Here, we applied the concept of pre-PCR processing to optimize RT-qPCR detection of norovirus genogroup I (GI), genogroup II (GII), and hepatitis A virus (HAV) in challenging water matrices. The RT-qPCR assay was improved by screening for an inhibitor-tolerant master mix and modifying the primers with twisted intercalating nucleic acid molecules. Additionally, a modified protocol based on chaotropic lysis buffer and magnetic silica bead nucleic acid extraction was developed for complex water matrices. A validation of the modified extraction protocol on surface and drinking waters was performed. At least a 26-fold improvement was seen in the most complex surface water studied. The modified protocol resulted in average recoveries of 33, 13, 8, and 4% for mengovirus, norovirus GI, GII, and HAV, respectively. The modified protocol also improved the limit of detection for norovirus GI and HAV. RT-qPCR inhibition with C q shifts of 1.6, 2.8, and 3.5 for norovirus GI, GII, and HAV, respectively, obtained for the standard nucleic acid extraction were completely eliminated by the modified protocol. The standard nucleic acid extraction method worked well on drinking water with no RT-qPCR inhibition observed and average recoveries of 80, 124, 89, and 32% for mengovirus, norovirus GI, GII, and HAV, respectively.
Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria
2011-09-01
Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected <40 cp/mL" in the standard assay. The "modified" and "ultrasensitive" assays are precise and accurate, and easily adoptable in routine diagnostic laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.
The Ĝ Infrared Search for Extraterrestrial Civilizations with Large Energy Supplies
NASA Astrophysics Data System (ADS)
Wright, Jason Thomas; Povich, Matthew; Griffith, Roger; Maldonado, Jessica; Sigurdsson, Steinn; Star Cartier, Kimberly
2015-08-01
The WISE and Spitzer large-area surveys of the mid-infrared sky bring a new opportunity to search for evidence of the energy supplies of very large extraterrestrial civilizations. If these energy supplies rival the output of a civilization's parent star (Kardashev Type II), or if a galaxy-spanning supercivilization's use rivals that of the total galactic luminosity (Type III), they would be detectable as anomolously mid-infrared-bright stars and galaxies, respectively. We have already performed the first search for this emission from Type III civilizations using the WISE all-sky survey, and put the first upper limits on them in the local universe, and discuss ways to improve on these limits. We also discuss some detectable forms of and limits on Type II civilizations in the Mliky Way.
Alhassan, Andy; Govind, Yadav; Tam, Nguyen Thanh; Thekisoe, Oriel M M; Yokoyama, Naoaki; Inoue, Noboru; Igarashi, Ikuo
2007-04-01
The sensitivity of LAMP, PCR and in vitro culture methods for the detection of Theileria equi and Babesia caballi was evaluated using tenfold serially diluted culture parasites. On day 1 post-culture, both T. equi and B. caballi parasites could only be observed at 1% parasite dilution from the in vitro culture method, whereas LAMP could detect up to 1 x 10(-3)% of both T. equi and B. caballi parasite dilutions, whilst PCR could detect 1 x 10(-3)% T. equi and 1 x 10(-1)% B. caballi parasite dilutions. On day 7 post-culture, the detection limit for T. equi and B. caballi in the in vitro culture increased up to 1 x 10(-6)%, whereas LAMP detection limit increased to 1 x 10(-10)% for both parasites, whilst the PCR detection limit increased to 1 x 10(-10)% and 1 x 10(-6)% for T. equi and B. caballi, respectively. Furthermore, LAMP and PCR amplified the T. equi DNA extracted from the organs of an experimentally infected horse. This study further validates LAMP as an alternative molecular diagnostic tool, which can be used in the diagnosis of early infections of equine piroplasmosis and together with PCR can also be used as supplementary methods during post-mortems.
Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal; Capell, Nuria Estañ; Köller, Ursula; Lackner, Karl; Lefèvre, Guillaume; Lennartz, Lieselotte; Lotz, Johannes; Herranz, Antonio Mora; Nybo, Mads; Plebani, Mario; Sandberg, Maria B; Schratzberger, Wolfgang; Shih, Jessie; Skadberg, Øyvind; Chargui, Ahmed Taoufik; Zaninotto, Martina; Sypniewska, Grazyna
2014-11-01
International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study. Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent. The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.
Cortés-Hinojosa, Galaxia; Gulland, Frances M D; Goldstein, Tracey; Venn-Watson, Stephanie; Rivera, Rebecca; Archer, Linda L; Waltzek, Thomas B; Gray, Gregory C; Wellehan, James F X
2017-03-01
California sea lion adenovirus 1 (CSLAdV-1) has been associated with hepatitis and enteritis in several wild and captive populations of diverse pinniped species. Currently available tests have been limited to pan-adenoviral polymerase chain reaction (PCR) followed by sequencing. We present the development of a quantitative probe-hybridization PCR (qPCR) assay for rapid, sensitive, and specific detection of this virus in California sea lions ( Zalophus californianus) and other pinnipeds. This assay did not amplify other mammalian adenoviruses and is able to detect consistently down to 10 viral copies per well. Compared with the gold standard conventional pan-adenovirus PCR/sequencing assay, diagnostic sensitivity and specificity of 100% and 88.2% were found, respectively. The lower diagnostic specificity of this qPCR assay may be the result of the lower limit of detection of this assay compared with the gold standard rather than the result of detection of true false-positives.
Kumar, Ashwini; Singh, Baldev; Malik, Ashok Kumar; Tiwary, Dhananjay K
2007-01-01
A new approach has been developed for the extraction and determination of aldehydes such as veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde by using solid-phase microextraction (SPME) and high-performance liquid chromatography with UV detection (HPLC/UV). The method involves adsorption of the aldehydes on polydimethylsiloxane/divinylbenzene-coated fiber, followed by desorption in the desorption chamber of the SPME-HPLC interface, using acetonitrile-water (70 + 30) as the mobile phase; UV detection was at 254 nm. A good separation of 5 aldehydes was obtained on a C18 column. The detection limits of veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde are 25, 41, 13, 12, and 11 pg/mL, respectively, which are about 100 times better than the detection limits for other SPME methods using gas chromatography. The proposed method was validated by determining benzaldehyde in bitter almonds and cinnamaldehyde in cinnamon bark. The recoveries of the 5 analytes were determined by analysis of spiked drinking water.
Nithya, Ravichantar; Ahmed, Siti Aminah; Hoe, Chee-Hock; Gopinath, Subash C B; Citartan, Marimuthu; Chinni, Suresh V; Lee, Li Pin; Rozhdestvensky, Timofey S; Tang, Thean-Hock
2015-01-01
Salmonellosis, a communicable disease caused by members of the Salmonella species, transmitted to humans through contaminated food or water. It is of paramount importance, to generate accurate detection methods for discriminating the various Salmonella species that cause severe infection in humans, including S. Typhi and S. Paratyphi A. Here, we formulated a strategy of detection and differentiation of salmonellosis by a multiplex polymerase chain reaction assay using S. Typhi non-protein coding RNA (sRNA) genes. With the designed sequences that specifically detect sRNA genes from S. Typhi and S. Paratyphi A, a detection limit of up to 10 pg was achieved. Moreover, in a stool-seeding experiment with S. Typhi and S. Paratyphi A, we have attained a respective detection limit of 15 and 1.5 CFU/mL. The designed strategy using sRNA genes shown here is comparatively sensitive and specific, suitable for clinical diagnosis and disease surveillance, and sRNAs represent an excellent molecular target for infectious disease.
Sipilanyambe Munyinda, Nosiku; Michelo, Charles; Sichilongo, Kwenga
2015-01-01
Background. In 2000, a Zambian private mining company reintroduced the use of dichlorodiphenyltrichloroethane (DDT) to control malaria in two districts. From 2000 to 2010, DDT had been applied in homes without any studies conducted to ascertain its fate in the environment. We aimed to quantify the presence of DDT and its metabolites in the soil and water around communities where it was recently used. Methods. We collected superficial soil and water samples from drinking sources of three study areas. DDT was extracted by QuEChERS method and solid phase extraction for soils and water, respectively. Analysis was by gas chromatography-mass spectrometry. A revalidated method with limits of detection ranging from 0.034 to 0.04 ppb was used. Results. Median levels of total DDT were found at 100.4 (IQR 90.9–110) and 725.4 ng/L (IQR 540–774.5) for soils and water, respectively. No DDT above detection limits was detected in the reference area. These results are clinically significant given the persistent characteristics of DDT. Conclusion. DDT presence in these media suggests possible limitations in the environmental safeguards during IRS. Such occurrence could have potential effects on humans, especially children; hence, there is a need to further examine possible associations between this exposure and humans. PMID:26579199
Detection of two fungal biocontrol agents against root-knot nematodes by RAPD markers.
Zhu, Ming Liang; Mo, Ming He; Xia, Zhen Yuan; Li, Yun Hua; Yang, Shu Jun; Li, Tian Fei; Zhang, Ke Qin
2006-05-01
The strain ZK7 of Pochonia chlamydosporia var. chlamydosporia and IPC of Paecilomyces lilacinus are highly effective in the biological control against root-knot nematodes infecting tobacco. When applied, they require a specific monitoring method to evaluate the colonization and dispersal in soil. In this work, the randomly amplified polymorphic DNA (RAPD) technique was used to differentiate between the two individual strains and 95 other isolates, including isolates of the same species and common soil fungi. This approach allowed the selection of specific fragments of 1.2 kb (Vc1200) and 2.0 kb (Vc2000) specific for ZK7, 1.4 kb (P1400) and 0.85 kb (P850) specific for IPC, using the random Primers OPL-02, OPD-05, OPD-05 and OPC-11, respectively. These fragments were cloned, sequenced, and used to design sequence-characterized amplification region (SCAR) primers specific for the two strains. In classical polymerase chain reaction (PCR), with serial dilution of ZK7 and IPC pure culture DNAs template, the detection limits of these oligonucleotide SCAR-PCR primers were found to be 10, 1000, 500, 100 pg, respectively. In the dot blotting, digoxigenin (DIG)-labeled amplicons from these four primers specifically recognized the corresponding fragments in the DNAs template of these two strains. The detection limit of these amplicons were 0.2, 0.2, 0.5, 0.5 mug, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deruaz, D.; Bannier, A.; Pionchon, C.
1995-08-01
This paper deals with the optimal conditions for the detection of {sup 15}N determined using a four-factor experimental design from [2{sup 13}C,-1,3 {sup 15}N] caffeine measured with an atomic emission detector (AED) coupled to gas chromatography (GC). Owing to the capability of a photodiodes array, AED can simultaneously detect several elements using their specific emission lines within a wavelength range of 50 nm. So, the emissions of {sup 15}N and {sup 14}N are simultaneously detected at 420.17 nm and 421.46 nm respectively. Four independent experimental factors were tested (1) helium flow rate (plasma gas); (2) methane pressure (reactant gas); (3)more » oxygen pressure; (4) hydrogen pressure. It has been shown that these four gases had a significant influence on the analytical response of {sup 15}N. The linearity of the detection was determined using {sup 15}N amounts ranging from 1.52 pg to 19 ng under the optimal conditions obtained from the experimental design. The limit of detection was studied using different methods. The limits of detection of {sup 15}N was 1.9 pg/s according to the IUPAC method (International-Union of Pure and Applied Chemistry). The method proposed by Quimby and Sullivan gave a value of 2.3 pg/s and that of Oppenheimer gave a limit of 29 pg/s. For each determination, and internal standard: 1-isobutyl-3.7 dimethylxanthine was used. The results clearly demonstrate that GC AED is sensitive and selective enough to detect and measure {sup 15}N-labelled molecules after gas chromatographic separation.« less
Akkbik, Mohammed; Assim, Zaini Bin; Ahmad, Fasihuddin Badruddin
2011-01-01
An HPLC method with ultraviolet-visible spectrophotometry detection has been optimized and validated for the simultaneous determination of phenolic compounds, such as butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) as antioxidants, and octyl methyl cinnamate (OMC) as UVB-filter in several personal care products. The dynamic range was between 1 to 250 mg/L with relative standard deviation less than 0.25% (n = 4). Limits of detection for BHA, BHT, and OMC were 0.196, 0.170, and 0.478 mg/L, respectively. While limits of quantification for BHA, BHT, and OMC were 0.593, 0.515, and 1.448 mg/L, respectively. The recovery for BHA, BHT, and OMC was ranged from 92.1–105.9%, 83.2–108.9%, and 87.3–103.7%, respectively. The concentration ranges of BHA, BHT, and OMC in 12 commercial personal care samples were 0.13–4.85, 0.16–2.30, and 0.12–65.5 mg/g, respectively. The concentrations of phenolic compounds in these personal care samples were below than maximum allowable concentration in personal care formulation, that is, 0.0004–10 mg/g, 0.002–5 mg/g, and up to 100 mg/g for BHA, BHT, and OMC, respectively. PMID:21760792
NASA Astrophysics Data System (ADS)
Chasteen, Thomas Girard
1990-01-01
The first part of this dissertation describes capillary chromatography coupled to a fluorine-induced chemiluminescence detector as a sensitive method by which biologically methylated metalloids can be determined in the presence of high concentrations of potentially interfering molecules. With a wide linear range and excellent sensitivity, this method was applied to the detection of dimethyl selenide (DMSe), dimethyl diselenide (DMDSe), and dimethyl telluride (DMTe), often found in biological environments in the presence of interfering methylated sulfur gases, such as methanethiol, dimethyl sulfide, dimethyl disulfide, and dimethyl trisulfide. Detection limits for DMSe, DMDSe, and DMTe were 30, 9, and 7 picograms, respectively. This DMTe detection limit is the lowest reported to date for a volatile tellurium gas. A variety of selenium-resistant bacteria emitted mixtures of methylated sulfur/selenium gases when dosed with inorganic selenium salts in the presence of sulfur containing growth media. One of the gases detected was dimethyl selenenyl sulfide, CH_3SeSCH _3, reported here for the first time in headspace above microorganisms. In addition, this detector responded to reduced phosphorus compounds such as phosphine. The detection limit for this compound was 2.8 picograms. Detection limits for alkylated phosphines trimethyl and triethyl phosphine were 0.5 and 17 picograms respectively, based on the relative response of these compounds compared to dimethyl sulfide. This method can be used for the simultaneous determination of methylated sulfur, selenium, tellurium compounds found in biological systems. Part II of this dissertation describes work with methyldithiocarbhydrazide, a compound that has been synthesized for use as a derivatization reagent to capture formaldehyde in the gas phase. Chosen for its ability to react in a manner similar to 2,4-dinitrophenylhydrazine, this molecule was selected based on two structural characteristics: a hydrazine tag to react with and thereby capture carbonyls and a methyl sulfide group to allow for sensitive detection by fluorine-induced chemiluminescence. Although in the final analysis methyldithiocarbohydrazide failed as a successful means by which formaldehyde can be determined using gas chromatography in conjunction with fluorine-induced chemiluminescence, it did successfully derivatize formaldehyde in both solution and the gas phase without the need for low pH conditions.
Occurrence of ivermectin in bovine milk from the Brazilian retail market.
Lobato, V; Rath, S; Reyes, F G R
2006-07-01
High-performance liquid chromatography (HPLC) with fluorescence detection was used for the quantification of ivermectin residues in bovine milk intended for human consumption. After liquid-liquid extraction of ivermectin and purification of the extract, the compound was derivatized with 1-methylimidazol in N,N-dimethyl formamide to form a fluorescent derivative, which was separated by HPLC, using reversed-phase C18, with methanol : water (96 : 4 v/v) mobile phase at a flow rate 0.7 ml min-1. The excitation and emission wavelengths of the fluorescence detector were adjusted at 360 and 470 nm, respectively. The linearity of the method was in the range 10-100 ng ivermectin ml-1. Based on a sample of 5.0 ml, the limit of detection and the limit of quantification for ivermectin in milk were 0.6 and 2 ng ml-1, respectively. The recovery rate varied from 76.4 to 87.2%, with an average of 77.9 +/- 3.2%, at four fortification levels. The inter-day precision of the method was 13% (n = 5). Of 168 samples analysed, 17.8% contained ivermectin above the limit of quantification. Nevertheless, none of the samples contained ivermectin above the maximum residue limit (10 ng ml-1) established by the Brazilian Ministry of Agriculture.
A novel dNTP-limited PCR and HRM assay to detect Williams-Beuren syndrome.
Zhang, Lichen; Zhang, Xiaoqing; You, Guoling; Yu, Yongguo; Fu, Qihua
2018-06-01
Williams-Beuren syndrome (WBS) is caused by a microdeletion of chromosome arm 7q11.23. A rapid and inexpensive genotyping method to detect microdeletion on 7q11.23 needs to be developed for the diagnosis of WBS. This study describes the development of a new type of molecular diagnosis method to detect microdeletion on 7q11.23 based upon high-resolution melting (HRM). Four genes on 7q11.23 were selected as the target genes for the deletion genotyping. dNTP-limited duplex PCR was used to amplify the reference gene, CFTR, and one of the four genes respectively on 7q11.23. An HRM assay was performed on the PCR products, and the height ratio of the negative derivative peaks between the target gene and reference gene was employed to analyze the copy number variation of the target region. A new genotyping method for detecting 7q11.23 deletion was developed based upon dNTP-limited PCR and HRM, which cost only 96 min. Samples from 15 WBS patients and 12 healthy individuals were genotyped by this method in a blinded fashion, and the sensitivity and specificity was 100% (95% CI, 0.80-1, and 95% CI, 0.75-1, respectively) which was proved by CytoScan HD array. The HRM assay we developed is an rapid, inexpensive, and highly accurate method for genotyping 7q11.23 deletion. It is potentially useful in the clinical diagnosis of WBS. Copyright © 2018 Elsevier B.V. All rights reserved.
A search for HI in some peculiar faint dwarf galaxies
NASA Astrophysics Data System (ADS)
Begum, Ayesha; Chengalur, Jayaram N.
2005-09-01
We present a deep Giant Metrewave Radio Telescope (GMRT) search for HI 21-cm emission from three dwarf galaxies, viz. POX 186, SC 24 and KKR 25. Based, in part, on previous single-dish HI observations, these galaxies have been classified as a blue compact dwarf (BCD), a dwarf irregular and a transition galaxy, respectively. However, in conflict with previous single-dish detections, we do not detect HI in SC 24 or KKR 25. We suggest that the previous single-dish measurements were probably confused with the local Galactic emission. In the case of POX 186, we confirm the previous non-detection of HI but with substantially improved limits on its HI mass. Our derived upper limits on the HI mass of SC 24 and KKR 25 are similar to the typical HI mass limit for dwarf spheroidal (dSph) galaxies, whereas in the case of POX 186, we find that its gas content is somewhat smaller than is typical of BCD galaxies.
Lee, Ji Sun; Cho, Soo Hee; Lim, Chae Mi; Chang, Moon Ik; Joo, Hyun Jin; Park, Hyun Jin
2017-01-01
A confirmatory and quantitative method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of mebendazole and its hydrolyzed and reduced metabolites in pork, chicken, and horse muscles was developed and validated in this study. Anthelmintic compounds were extracted with ethyl acetate after sample mixture was made alkaline followed by liquid chromatographic separation using a reversed phase C18 column. Gradient elution was performed with a mobile phase consisting of water containing 10 mM ammonium formate and methanol. This confirmatory method was validated according to EU requirements. Evaluated validation parameters included specificity, accuracy, precision (repeatability and within-laboratory reproducibility), analytical limits (decision limit and detection limit), and applicability. Most parameters were proved to be conforming to the EU requirements. The decision limit (CCα) and detection capability (CCβ) for all analytes ranged from 15.84 to 17.96 μgkg-1. The limit of detection (LOD) and the limit of quantification (LOQ) for all analytes were 0.07 μgkg-1 and 0.2 μgkg-1, respectively. The developed method was successfully applied to monitoring samples collected from the markets in major cities and proven great potential to be used as a regulatory tool to determine mebendazole residues in animal based foods. PMID:28085912
Compact TDLAS based sensor design using interband cascade lasers for mid-IR trace gas sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Lei; Tittel, Frank K.; Li, Chunguang
2016-02-25
Two compact TDLAS sensor systems based on different structural optical cores were developed. The two optical cores combine two recent developments, gallium antimonide (GaSb)-based ICL and a compact multipass gas cell (MPGC) with the goal to create compact TDLAS based sensors for the mid-IR gas detection with high detection sensitivity and low power consumption. The sensors achieved minimum detection limits of ~5 ppbv and ~8 ppbv, respectively, for CH 4 and C 2H 6 concentration measurements with a 3.7-W power consumption.
Ali, Soleimani Gezeljeh; Darvishzadeh, Reza; Ebrahimi, Asa; Bihamta, Mohammad Reza
2018-03-01
Sunflower is an important source of edible oil. Drought is known as an important factor limiting the growth and productivity of field crops in most parts of the world. Agricultural biotechnology mainly aims at developing crops with higher tolerance to the challenging environmental conditions, such as drought. This study examined a number of morphological characters, along with relative water content (RWC) in 100 inbred sunflower lines. A 10 × 10 simple lattice design with two replications was employed to measure the mentioned parameters under natural and water-limited states during two successive years. In molecular trial, 30 simple sequence repeat (SSR) primer pairs, as well as 14 inter-retrotransposon amplified polymorphism (IRAP) and 14 retrotransposon-microsatellite amplified polymorphism (REMAP) primer combinations were used for DNA fingerprinting of the lines. Most of the examined characters had lower average values under water-limited than natural states. Maximum and minimum reductions were observed in the cases of yield and oil percentage, respectively. The broad-sense heritabilities for all the examined characters were 0.20-0.73 and 0.10-0.34 under natural and water-limited states, respectively. In the studied samples, 8.97% of the 435 possible locus pairs of the SSRs represented significant linkage disequilibrium (LD) levels. In the association analysis using SSR markers, 22 and 21 markers were identified (P ≤ 0.05) for the studied characters under natural and water-limited states, respectively. The corresponding values were 50 and 37 using retrotransposon-based molecular markers. Some detected markers were communal between the characters under water-limited and natural states. This was in line with the phenotypic correlations detected between the characters. Communal markers facilitate the simultaneous selection of several characters and can thus improve the efficacy of selection based on markers in the plant-breeding activities.
NASA Astrophysics Data System (ADS)
Thimaradka, Vikram; Pangannaya, Srikala; Mohan, Makesh; Trivedi, Darshak R.
2018-03-01
A series of new receptors PDZ1-3 based on 2-(arylidenehydrazinyl)pyridines have been designed and synthesized for the detection of biologically and environmentally important ions. The colorimetric detection of CO32 - using neutral organic receptor PDZ-1 has been achieved with characteristic visual colour change from yellow to green accompanied by a large redshift of 215 nm in absorption maxima. UV-Vis spectroscopic and cyclic voltammetric studies reveal the stoichiometry of binding and electrochemistry of host-guest complex formation. The binding constant was found to be 0.77 × 104 M- 2. In addition, electrochemical studies provide an insight into the stability of the complex. DFT studies performed on the PDZ-1 and PDZ-1 - CO32 - complex reveal the binding mechanism involved in the anion detection process. PDZ-1 is highly selective for carbonate and does not show any colorimetric response towards any other anions or cations, while PDZ-2 and PDZ-3 remain inactive in the ion detection process. The limit of detection (LOD) and limit of quantification (LOQ) of PDZ-1 for carbonate was found to be 0.11 mM and 0.36 mM respectively. Considerable binding constant and limit of detection make PDZ-1 to be used as a real time sensor for the detection of carbonate in environmental and biological samples.
Surface plasmon resonance biosensor for enzymatic detection of small analytes
NASA Astrophysics Data System (ADS)
Massumi Miyazaki, Celina; Makoto Shimizu, Flávio; Mejía-Salazar, J. R.; Oliveira, Osvaldo N., Jr.; Ferreira, Marystela
2017-04-01
Surface plasmon resonance (SPR) biosensing is based on the detection of small changes in the refractive index on a gold surface modified with molecular recognition materials, thus being mostly limited to detecting large molecules. In this paper, we report on a SPR biosensing platform suitable to detect small molecules by making use of the mediator-type enzyme microperoxidase-11 (MP11) in layer-by-layer films. By depositing a top layer of glucose oxidase or uricase, we were able to detect glucose or uric acid with limits of detection of 3.4 and 0.27 μmol l-1, respectively. Measurable SPR signals could be achieved because of the changes in polarizability of MP11, as it is oxidized upon interaction with the analyte. Confirmation of this hypothesis was obtained with finite difference time domain simulations, which also allowed us to discard the possible effects from film roughness changes observed in atomic force microscopy images. The main advantage of this mediator-type enzyme approach is in the simplicity of the experimental method that does not require an external potential, unlike similar approaches for SPR biosensing of small molecules. The detection limits reported here were achieved without optimizing the film architecture, and therefore the performance can in principle be further enhanced, while the proposed SPR platform may be extended to any system where hydrogen peroxide is generated in enzymatic reactions.
Sichilongo, Kwenga; Chinyama, Mompati; Massele, Amos; Vento, Sandro
2014-01-15
A contrast between the analytical performance characteristics using gas chromatography-mass spectrometry (GC-MS) liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-ultraviolet (LC-UV) detection for the determination of the antiretroviral drug (ARV) nevirapine (NVP) in fortified human plasma after QuEChERS extraction has been made. Analytical performance characteristics, i.e. linearities, instrument detection limits (IDLs), limits of quantitation (LOQs), method detection limits (MDLs), % mean recoveries and the corresponding relative standard deviations (%RSDs) were estimated using techniques above. Using GC-MS, the correlation coefficients (r(2)) were ≥0.990, which were deemed acceptable linearities. The MDLs ranged between 11.1-29.8μg/L and 13.7-36.0μg/L using helium and hydrogen carrier gases respectively. The LOQs ranged between 16.5-66.7μg/L and 28.4-98.7μg/L using helium and hydrogen carrier gases respectively with a % mean recovery of 83% and %RSD of 4.6%. Using LC-MS and LC-UV, the correlation coefficients (r(2)) were ≥0.990. The MDLs were ranged between 3.14 and 47.1μg/L. The LOQs ranged between 2.85 and 90.0μg/L respectively. The MDLs using GC-MS, LC-MS and LC-UV were below the therapeutic range for NVP in human plasma is considered to be between 2300μg/L (Cmin) and 8000μg/L (Cmax). This study also demonstrated that helium can be substituted with hydrogen which is relatively cheaper and easily obtainable even by use of a generator. Copyright © 2013 Elsevier B.V. All rights reserved.
Granja, Rodrigo H M M; De Lima, Andreia C; Salerno, Alessandro G; Wanschel, Amarylis C B A
2013-01-01
Sulfonamides are one class of antimicrobial agents used in aquaculture production. Sulfonamides are often overused because they are inexpensive and readily available. Their presence at a concentration above the legal limits is a potential hazard to human health. Brazilian authorities have included in the National Regulatory Monitoring Program the control of the three most widely used sulfonamides in aquaculture production, i.e., sulfathiazole, sulfamethazine, and sulfadimethoxine. An LC method with UV detection for the determination of residual sulfonamides in fish muscle, using sulfapyridine as an internal standard has been developed and validated. The validation was performed according to the Brazilian Regulation 24/2009 (equivalent to European Union Decision 2002/657/EC). The method meets the Brazilian regulatory requirement that establishes criteria and procedures for determination of parameters such as decision limit (CCalpha), detection capability (CCbeta), precision, and recovery. For fish muscle, CCalpha was determined at 3.63, 2.91, and 7.46 microg/kg for sulfathiazole, sulfamethazine, and sulfadimethoxine, respectively. CCbeta was 9.39, 14.54, and 9.39 microg/kg for sulfathiazole, sulfamethazine, and sulfadimethoxine, respectively. For shrimp, CCalpha was 11.5, 8.67, and 4.46 microg/kg for sulfathiazole, sulfamethazine, and sulfadimethoxine, respectively. CCbeta was 18, 11.93, and 5.24 microg/kg for sulfathiazole, sulfamethazine, and sulfadimethoxine, respectively. A complete statistical analysis was performed on the results obtained. The results indicate that the method is robust when subjected to day-to-day analytical variations.
Multi-Source Fusion for Explosive Hazard Detection in Forward Looking Sensors
2016-12-01
include; (1) Investigating (a) thermal, (b) synthetic aperture acoustics ( SAA ) and (c) voxel space Radar for buried and side threat attacks. (2...detection. (3) With respect to SAA , we developed new approaches in the time and frequency domains for analyzing signature of concealed targets (called...Fraz). We also developed a method to extract a multi-spectral signature from SAA and deep learning was used on limited training and class imbalance
Amines in boreal forest air at SMEAR II station in Finland
NASA Astrophysics Data System (ADS)
Hemmilä, Marja; Hellén, Heidi; Virkkula, Aki; Makkonen, Ulla; Praplan, Arnaud P.; Kontkanen, Jenni; Ahonen, Lauri; Kulmala, Markku; Hakola, Hannele
2018-05-01
We measured amines in boreal forest air in Finland both in gas and particle phases with 1 h time resolution using an online ion chromatograph (instrument for Measuring AeRosols and Gases in Ambient Air - MARGA) connected to an electrospray ionization quadrupole mass spectrometer (MS). The developed MARGA-MS method was able to separate and detect seven different amines: monomethylamine (MMA), dimethylamine (DMA), trimethylamine (TMA), ethylamine (EA), diethylamine (DEA), propylamine (PA), and butylamine (BA). The detection limits of the method for amines were low (0.2-3.1 ng m-3), the accuracy of IC-MS analysis was 11-37 %, and the precision 10-15 %. The proper measurements in the boreal forest covered about 8 weeks between March and December 2015. The amines were found to be an inhomogeneous group of compounds, showing different seasonal and diurnal variability. Total MMA (MMA(tot)) peaked together with the sum of ammonia and ammonium ions already in March. In March, monthly means for MMA were < 2.4 and 6.8 ± 9.1 ng m-3 in gas and aerosol phases, respectively, and for NH3 and NH4+ these were 52 ± 16 and 425 ± 371 ng m-3, respectively. Monthly medians in March for MMA(tot), NH3, and NH4+ were < 2.4, 19 and 90 ng m-3, respectively. DMA(tot) and TMA(tot) had summer maxima indicating biogenic sources. We observed diurnal variation for DMA(tot) but not for TMA(tot). The highest concentrations of these compounds were measured in July. Then, monthly means for DMA were < 3.1 and 8.4 ± 3.1 ng m-3 in gas and aerosol phases, respectively, and for TMA these were 0.4 ± 0.1 and 1.8 ± 0.5 ng m-3. Monthly medians in July for DMA were below the detection limit (DL) and 4.9 ng m-3 in gas and aerosol phases, respectively, and for TMA these were 0.4 and 1.4 ng m-3. When relative humidity of air was > 90 %, gas-phase DMA correlated well with 1.1-2 nm particle number concentration (R2 = 0.63) suggesting that it participates in atmospheric clustering. EA concentrations were low all the time. Its July means were < 0.36 and 0.4 ± 0.4 ng m-3 in gas and aerosol phases, respectively, but individual concentration data correlated well with monoterpene concentrations in July. Monthly means of PA and BA were below detection limits at all times.
Wang, Ning; Wang, Yiting; Guo, Tingting; Yang, Ting; Chen, Mingli; Wang, Jianhua
2016-11-15
A simple one-step hydrothermal green approach was reported for the preparation of carbon dots (CDs) without any further decoration or modification with papaya powder as natural carbon source. In this economical and eco-friendly system, deionized water or 90% ethanol was used as solvent to produce water-soluble or ethanol-soluble CDs, respectively, termed as W-CDs and E-CDs. The quantum yield (QY) for W-CDs was 18.98%, while that for E-CDs was 18.39%. The potentials of the prepared carbon dots toward diverse applications were thoroughly investigated. W-CDs and E-CDs provide promising probes for fluorescence detection of Fe(3+), offering limits of detection of 0.48μmolL(-1) and 0.29μmolL(-1), respectively. W-CDs was further demonstrated to be a promising probe for fluorescence sensing of Escherichia coli O157: H7, along with a limit of detection of 9.5×10(4)cfumL(-1). Meanwhile, both W-CDs and E-CDs exhibit favorable biocompatibility, and demonstrated to be efficient for Hela cell imaging. Copyright © 2016 Elsevier B.V. All rights reserved.
Simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations by MEKC.
Yardimci, Ceren; Ozaltin, Nuran
2010-02-01
A micellar electrokinetic capillary chromatography method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations. The influence of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, capillary temperature, applied voltage, and injection time was investigated, and the method validation studies were performed. The optimum separation for these analytes was achieved in less than 10 min at 30 degrees C with a fused-silica capillary column (56 cm x 50 microm i.d.) and a 25mM borate buffer at pH 9.0 containing 25mM SDS and 10% (v/v) acetonitrile. The samples were injected hydrodynamically for 3 s at 50 mbar, and the applied voltage was +30.0 kV. Detection wavelength was set at 238 nm. Diflunisal was used as internal standard. The method was suitably validated with respect to stability, specificity, linearity, limits of detection and quantification, accuracy, precision, and robustness. The limits of detection and quantification were 1.0 and 2.0 microg/mL for both ezetimibe and simvastatin, respectively. The method developed was successfully applied to the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations.
NASA Astrophysics Data System (ADS)
Dey, Nibedita; Devasena, T.; Sivalingam, Tamilarasu
2018-02-01
This work reports a comparative study on the development of a sensitive voltammetric method for the assay of diferuloylmethane which is fabricated using cost-effective sensing material graphene oxide (GO modified electrode) and reduced graphene oxide (rGO modified electrode) modified on glassy carbon electrode respectively. The prepared materials were characterized using SEM, XRD, FTIR, and Raman techniques to understand the formation. Between the both modified electrodes, rGO modified electrode demonstrated a lower limit detection of 0.9 pM and good signal quality. But, the better linear dynamic range for detection was found to be 1 nm to 100 nM for GO and 0.1 nM to 10 nM for rGO modified electrodes respectively. The repeatability is checked for seven cycles and interference studies were also performed for checking the sensors’ selectivity to curcumin. rGO modified electrode and GO modified electrode both shows specific signals for Diferuloylmethane under conditions similar to physiology. But, with better properties over GO modified electrode, rGO modified electrode is suggested a better candidate for real-time usability in sensing. The detection limit reported is the lowest till date for the given plant drug using any sensing assay.
[Determination of residual solvents in 7-amino-3-chloro cephalosporanic acid by gas chromatography].
Ma, Li; Yao, Tong-wei
2011-01-01
To develop a gas chromatography method for determination of residual solvents in 7-amino-3-chloro cephalosporanic acid (7-ACCA). The residual levels of acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine and toluene in 7-ACCA were measured by gas chromatography using Agilent INNOWAX capillary column (30 m × 0.32 mm,0.5 μm). The initial column temperature was 70° maintained for 6 min and then raised (10°C/min) to 160°C for 1 min. Nitrogen gas was used as carrier and FID as detector. The flow of carrier was 1.0 ml/min, the temperature of injection port and detector was 200°C and 250°C, respectively. The limits of detection for acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine, toluene in 7-ACCA were 2.5 μg/ml, 1.5 μg/ml, 15 μg/ml, 2.5 μg/ml, 2.5 μg/ml, 2.5 μg/ml and 11 μg/ml, respectively. Only acetone was detected in the sample, and was less than the limits of Ch.P. The method can effectively detect the residual solvents in 7-ACCA.
Rapid detection of mecA and spa by the loop-mediated isothermal amplification (LAMP) method.
Koide, Y; Maeda, H; Yamabe, K; Naruishi, K; Yamamoto, T; Kokeguchi, S; Takashiba, S
2010-04-01
To develop a detection assay for staphylococcal mecA and spa by using loop-mediated isothermal amplification (LAMP) method. Staphylococcus aureus and other related species were subjected to the detection of mecA and spa by both PCR and LAMP methods. The LAMP successfully amplified the genes under isothermal conditions at 64 degrees C within 60 min, and demonstrated identical results with the conventional PCR methods. The detection limits of the LAMP for mecA and spa, by gel electrophoresis, were 10(2) and 10 cells per tube, respectively. The naked-eye inspections were possible with 10(3) and 10 cells for detection of mecA and spa, respectively. The LAMP method was then applied to sputum and dental plaque samples. The LAMP and PCR demonstrated identical results for the plaque samples, although frequency in detection of mecA and spa by the LAMP was relatively lower for the sputum samples when compared to the PCR methods. Application of the LAMP enabled a rapid detection assay for mecA and spa. The assay may be applicable to clinical plaque samples. The LAMP offers an alternative detection assay for mecA and spa with a great advantage of the rapidity.
Design and characterization of a magnetoelastic sensor for the detection of biological agents
NASA Astrophysics Data System (ADS)
Shen, Wen; Mathison, Leslie C.; Petrenko, Valery A.; Chin, Bryan A.
2010-01-01
This paper presents the design and development of a free-standing, magnetoelastic biosensor. The detection principle is presented and various resonance characteristics of the sensor are discussed. Experimental measurements of the sensor resonance frequencies agree with theoretical predictions. The influence of the external magnetic field on the resonance behaviour of the sensor was studied and the optimum dc magnetic fields for best sensitivity in air and in water solutions for 2000 × 400 × 15 µm (2 mm) sensors and 1000 × 200 × 15 µm (1 mm) size sensors were determined to be 75 Oe and 38 Oe, respectively. Both theoretical prediction and experimental results show that smaller sensors have greater mass sensitivity and can theoretically detect mass as small as one biological spore. The sensor platform was immobilized with JRB7 phages for specific, in vitro detection of B. anthracis spores. Real-time detection of spores suspended in water was demonstrated using a flowing system. The 1 mm and 2 mm sensors were found to have a detection limit of 104 spores ml-1 and 105 spores ml-1, respectively.
Nondestructive evaluation of structural ceramics by photoacoustic microscopy
NASA Technical Reports Server (NTRS)
Khandelwal, Pramod K.
1987-01-01
A photoacoustic microscopy (PAM) digital imaging system was developed and utilized to characterize silicon nitride material at the various stages of the ceramic fabrication process. Correlation studies revealed that photoacoustic microscopy detected failure initiating defects in substantially more specimens than microradiography and ultrasonic techniques. Photoacoustic microscopy detected 10 to 100 micron size surface and subsurface pores and inclusions, respectively, up to 80 microns below the interrogating surface in machined sintered silicon nitride. Microradiography detected 50 micron diameter fracture controlling pores and inclusions. Subsurface holes were detected up to a depth of 570 microns and 1.00 mm in sintered silicon nitride and silicon carbide, respectively. Seeded voids of 20 to 30 micron diameters at the surface and 50 microns below the interrogating surface were detected by photoacoustic microscopy and microradiography with 1 percent X-ray thickness sensitivity. Tight surface cracks of 96 micron length x 48 micron depth were detected by photoacoustic microscopy. PAM volatilized and removed material in the green state which resulted in linear shallow microcracks after sintering. This significantly limits the use of PAM as an in-process NDE technique.
Diagnostic value of highly-sensitive chimerism analysis after allogeneic stem cell transplantation.
Sellmann, Lea; Rabe, Kim; Bünting, Ivonne; Dammann, Elke; Göhring, Gudrun; Ganser, Arnold; Stadler, Michael; Weissinger, Eva M; Hambach, Lothar
2018-05-02
Conventional analysis of host chimerism (HC) frequently fails to detect relapse before its clinical manifestation in patients with hematological malignancies after allogeneic stem cell transplantation (allo-SCT). Quantitative PCR (qPCR)-based highly-sensitive chimerism analysis extends the detection limit of conventional (short tandem repeats-based) chimerism analysis from 1 to 0.01% host cells in whole blood. To date, the diagnostic value of highly-sensitive chimerism analysis is hardly defined. Here, we applied qPCR-based chimerism analysis to 901 blood samples of 71 out-patients with hematological malignancies after allo-SCT. Receiver operating characteristics (ROC) curves were calculated for absolute HC values and for the increments of HC before relapse. Using the best cut-offs, relapse was detected with sensitivities of 74 or 85% and specificities of 69 or 75%, respectively. Positive predictive values (PPVs) were only 12 or 18%, but the respective negative predictive values were 98 or 99%. Relapse was detected median 38 or 45 days prior to clinical diagnosis, respectively. Considering also durations of steadily increasing HC of more than 28 days improved PPVs to more than 28 or 59%, respectively. Overall, highly-sensitive chimerism analysis excludes relapses with high certainty and predicts relapses with high sensitivity and specificity more than a month prior to clinical diagnosis.
Podhorniak, Lynda V; Kamel, Alaa; Rains, Diane M
2010-05-26
A rapid multiresidue method that captures residues of the insecticide formetanate hydrochloride (FHCl) in selected fruits is described. The method was used to provide residue data for dietary exposure determinations of FHCl. Using an acetonitrile extraction with a dispersive cleanup based on AOAC International method 2007.01, also known as QuEChERS, which was further modified and streamlined, thousands of samples were successfully analyzed for FHCl residues. FHCl levels were determined both by liquid chromatography-single-stage mass spectrometry (LC-MS) and ultraperformance liquid chromatography (UPLC)-tandem mass spectrometry (LC-MS/MS). The target limit of detection (LOD) and the limit of quantitation (LOQ) achieved for FHCl were 3.33 and 10 ng/g, respectively, with LC-MS and 0.1 and 0.3 ng/g, respectively, with LC-MS/MS. Recoveries at these previously unpublished levels ranged from 95 to 109%. A set of 20-40 samples can be prepared in one working day by two chemists.
Lee, Tien Ping; Saad, Bahruddin; Ng, Eng Poh; Salleh, Baharuddin
2012-05-11
Zeolite Linde Type L (LTL) crystals with different length, diameter and particle size (nanosized LTL, rod LTL, cylinder LTL and needle LTL) were synthesized, characterized and were used as sorbent in the micro-solid phase extraction of ochratoxin A (OTA) before the high performance liquid chromatography detection. Under the optimized conditions, the detection limits of OTA for coffee and cereal were 0.09 ng g(-1) and 0.03 ng g(-1), respectively, while the quantification limits were 0.28 ng g(-1) and 0.08 ng g(-1), respectively. The recoveries of OTA of coffee and cereal spiked at 0.5, 10 and 25 ng g(-1) ranged from 91.7 to 101.0%. The proposed method was applied to forty-five samples of coffee and cereal. The presence of OTA was found in twenty-five samples, ranging from 0.28 to 9.33 ng g(-1). Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gracy Elias; Earl D. Mattson; Jessica E. Little
A quantitative analytical method to determine butyramide and acetamide concentrations at the low ppb levels in geothermal waters has been developed. The analytes are concentrated in a preparation step by evaporation and analyzed using HPLC-UV. Chromatographic separation is achieved isocratically with a RP C-18 column using a 30 mM phosphate buffer solution with 5 mM heptane sulfonic acid and methanol (98:2 ratio) as the mobile phase. Absorbance is measured at 200 nm. The limit of detection (LOD) for BA and AA were 2.0 {mu}g L{sup -1} and 2.5 {mu}g L{sup -1}, respectively. The limit of quantification (LOQ) for BA andmore » AA were 5.7 {mu}g L{sup -1} and 7.7 {mu}g L{sup -1}, respectively, at the detection wavelength of 200 nm. Attaining these levels of quantification better allows these amides to be used as thermally reactive tracers in low-temperature hydrogeothermal systems.« less
Zhang, Shanshan; Liu, Xiaofei; Qin, Jia'an; Yang, Meihua; Zhao, Hongzheng; Wang, Yong; Guo, Weiying; Ma, Zhijie; Kong, Weijun
2017-11-15
A simple and rapid gas chromatography-flame photometric detection (GC-FPD) method was developed for the determination of 12 organophosphorus pesticides (OPPs) in Salvia miltiorrhizae by using ultrasonication assisted one-step extraction (USAE) without any clean-up steps. Some crucial parameters such as type of extraction solvent were optimized to improve the method performance for trace analysis. Any clean-up steps were negligent as no interferences were detected in the GC-FPD chromatograms for sensitive detection. Under the optimized conditions, limits of detection (LODs) and quantitation (LOQs) for all pesticides were in the range of 0.001-0.002mg/kg and 0.002-0.01mg/kg and 0.002-0.01mg/kg, respectively, which were all below the regulatory maximum residue limits suggested. RSDs for method precision (intra- and inter-day variations) were lower than 6.8% in approval with international regulations. Average recovery rates for all pesticides at three fortification levels (0.5, 1.0 and 5.0mg/kg) were in the range of 71.2-101.0% with relative standard deviations (RSDs) <13%. The developed method was evaluated for its feasibility in the simultaneous pre-concentration and determination of 12 OPPs in 32 batches of real S. miltiorrhizae samples. Only one pesticide (dimethoate) out of the 12 targets was simultaneously detected in four samples at concentrations of 0.016-0.02mg/kg. Dichlorvos and omethoate were found in the same sample from Sichuan province at 0.004 and 0.027mg/kg, respectively. Malathion and monocrotophos were determined in the other two samples at 0.014 and 0.028mg/kg, respectively. All the positive samples were confirmed by LC-MS/MS. The simple, reliable and rapid USAE-GC-FPD method with many advantages over traditional techniques would be preferred for trace analysis of multiple pesticides in more complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.
Graphite nanocomposites sensor for multiplex detection of antioxidants in food.
Ng, Khan Loon; Tan, Guan Huat; Khor, Sook Mei
2017-12-15
Butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), and tert-butylhydroquinone (TBHQ) are synthetic antioxidants used in the food industry. Herein, we describe the development of a novel graphite nanocomposite-based electrochemical sensor for the multiplex detection and measurement of BHA, BHT, and TBHQ levels in complex food samples using a linear sweep voltammetry technique. Moreover, our newly established analytical method exhibited good sensitivity, limit of detection, limit of quantitation, and selectivity. The accuracy and reliability of analytical results were challenged by method validation and comparison with the results of the liquid chromatography method, where a linear correlation of more than 0.99 was achieved. The addition of sodium dodecyl sulfate as supporting additive further enhanced the LSV response (anodic peak current, I pa ) of BHA and BHT by 2- and 20-times, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Inomata, Y; Matsunaga, K; Murai, Y; Osada, K; Iwasaka, Y
1999-12-09
A method for the simultaneous measurement of volatile sulfur compounds (COS, H2S, CS2, CH3SH, DMS) is established with preconcentration and GC-flame photometric detection (FPD). Prior to preconcentration of ambient air, it was necessary to remove SO2, water vapor and atmospheric oxidant. SO2 and water vapor were removed using a glass fiber filter and a cooled PTFE water trap loop, respectively. In order to remove atmospheric oxidant, the efficiency of an ascorbic acid scrubber was examined. It was found that an ascorbic acid scrubber enabled measurement of volatile sulfur compounds without adsorption and reaction loss. The detection limits for COS, H2S, CS2, CH3SH and DMS were 20, 34, 35, 263 and 44 pg of S, respectively.
Cheng, H; Pittman, K A; Dandekar, K A
1987-12-01
A simple and sensitive assay for quantitating 9-methyl-3-(1H-tetrazol-5-yl)-4H-pyrido[1,2-a]pyrimidin-4-one (1; BMY 26517) in human plasma was developed using high-performance liquid chromatography with fluorescence detection. The method involves precipitation of protein and reversed-phase chromatography. The method is linear in the range of 4.3-429 ng/mL of 1, and the limit of detection is 0.4 ng/mL. The day-to-day precision values of this method at 25.7 and 386 ng/mL are 2.1 and 2.6%, respectively. The day-to-day accuracy values at these concentrations are 99.7 and 99.8%, respectively. The recovery of 1 is 98.3%.
Pesticide Residues in Honey from the Major Honey Producing Forest Belts in Ghana.
Darko, Godfred; Addai Tabi, Jonah; Adjaloo, Michael Kodwo; Borquaye, Lawrence Sheringham
2017-01-01
Concentrations of pesticides residues in honey sampled from the major honey producing forest belts in Ghana were determined. Samples were purposively collected and extracted using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) method and analysed for synthetic pyrethroids, organochlorine, and organophosphate pesticide residues. Aldrin, γ -HCH, β -HCH, ∑endosulfan, cyfluthrin, cypermethrin, deltamethrin, permethrin methoxychlor, ∑DDT, chlorpyrifos, fenvalerate, malathion, dimethoate, and diazinon were all detected at the concentration of 0.01 mg/kg, while cyfluthrin and permethrin were detected at mean concentrations of 0.02 and 0.04 mg/kg, respectively. All the pesticide residues detected were very low and below their respective maximum residue limits set by the European Union. Hence, pesticide residues in honey samples analyzed do not pose any health risk to consumers.
Ivanov, A N; Younusov, R R; Evtugyn, G A; Arduini, F; Moscone, D; Palleschi, G
2011-07-15
A simple and reliable technique has been developed for the construction of an amperometric acetylcholinesterase biosensor based on screen-printed carbon electrodes. For the first time, one-step modification using single-walled carbon nanotubes and Co phtalocyanine has been proposed to decrease the working potential and to increase the signal of thiocholine oxidation. The biosensor developed made it possible to detect 5-50 ppb of paraoxon and 2-50 ppb of malaoxon with detection limits of 3 and 2 ppb, respectively (incubation 15 min). The biosensor showed high reproducibility when measurements of the substrate and inhibitor were performed (R.S.D. about 1% and 2.5%, respectively). The reliability of the inhibition measurements was confirmed by testing spiked samples of sparkling and tape waters. Copyright © 2011 Elsevier B.V. All rights reserved.
Thera, Jennifer C; Kidd, Karen A; Dodge-Lynch, M Elaine; Bertolo, Robert F
2017-12-15
We examined the performance of an ultra-high performance liquid chromatography method to quantify protein-bound sulphur amino acids in zooplankton. Both cysteic acid and methionine sulfone were linear from 5 to 250 pmol (r 2 = 0.99), with a method detection limit of 13 pmol and 9 pmol, respectively. Although there was no matrix effect on linearity, adjacent peaks and co-eluting noise from the invertebrate proteins increased the detection limits when compared to common standards. Overall, performance characteristics were reproducible and accurate, and provide a means for quantifying sulphur amino acids in aquatic invertebrates, an understudied group. Copyright © 2017 Elsevier Inc. All rights reserved.
Chobtang, Jeerasak; de Boer, Imke J. M.; Hoogenboom, Ron L. A. P.; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G.
2011-01-01
Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain. PMID:22247688
Chobtang, Jeerasak; de Boer, Imke J M; Hoogenboom, Ron L A P; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G
2011-01-01
Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain.
Niu, Kaili; Zheng, Xiaoping; Huang, Chusen; Xul, Kuan; Zhi, Yuan; Shen, Hebai; Jia, Nengqin
2014-07-01
An immunochromatographic test strip using gold nanoparticles-staphylococcus aureus monoclonal antibody conjugates was developed for the rapid and convenient detection of staphylococcus aureus based on a double-antibody sandwich format. The detection limit and the detection rate of this test strip is 10(3) CFU /mL and 98.7%, respectively. It could be used for the rapid detection of staphylococcus aureus in food and the results can be visually identified by the naked eye within 10 min. Compared with conventional bacterial detection methods, this developed immunochromatographic assay based test strip has several advantages including simple, fast, low-cost, favorable sensitivity and specificity, exhibiting a great potential for application in food safety control systems and clinical diagnosis.
Multiplexed detection of mycotoxins in foods with a regenerable array.
Ngundi, Miriam M; Shriver-Lake, Lisa C; Moore, Martin H; Ligler, Frances S; Taitt, Chris R
2006-12-01
The occurrence of different mycotoxins in cereal products calls for the development of a rapid, sensitive, and reliable detection method that is capable of analyzing samples for multiple toxins simultaneously. In this study, we report the development and application of a multiplexed competitive assay for the simultaneous detection of ochratoxin A (OTA) and deoxynivalenol (DON) in spiked barley, cornmeal, and wheat, as well as in naturally contaminated maize samples. Fluoroimmunoassays were performed with the Naval Research Laboratory array biosensor, by both a manual and an automated version of the system. This system employs evanescent-wave fluorescence excitation to probe binding events as they occur on the surface of a waveguide. Methanolic extracts of the samples were diluted threefold with buffer containing a mixture of fluorescent antibodies and were then passed over the arrays of mycotoxins immobilized on a waveguide. Fluorescent signals of the surface-bound antibody-antigen complexes decreased with increasing concentrations of free mycotoxins in the extract. After sample analysis was completed, surfaces were regenerated with 6 M guanidine hydrochloride in 50 mM glycine, pH 2.0. The limits of detection determined by the manual biosensor system were as follows: 1, 180, and 65 ng/g for DON and 1, 60, and 85 ng/g for OTA in cornmeal, wheat, and barley, respectively. The limits of detection in cornmeal determined with the automated array biosensor were 15 and 150 ng/g for OTA and DON, respectively.
Wang, Jun-liang; Xia, Qing; Zhang, An-ping; Hu, Xiao-yan; Lin, Chun-mian
2012-01-01
The widespread use of organophosphorus pesticides (OPs) poses a great threat to human health and has made the detection of OP residues in food an important task, especially in view of the fact that easy and rapid detection methods are needed. Because OPs have inhibitory effects on the activity of α-naphthyl acetate esterase (ANAE) in plants, in this work we evaluated the possibility of detecting OPs in vegetables with ANAE extracted from commercial flour. The limits of detection (LODs) obtained for methamidophos, dichlorvos, phoxim, dimethoate, and malathion in lettuce samples with crude ANAE were 0.17, 0.11, 0.11, 0.96, and 1.70 mg/kg, respectively. Based on the maximum residue limits (MRLs) for OPs in food stipulated by Chinese laws which are 0.05, 0.20, 0.05, 1.00, and 8.00 mg/kg for methamidophos, dichlorvos, phoxim, dimethoate, and malathion, respectively, the esterase inhibition method with crude ANAE had sufficient sensitivity to detect the residues of dichlorvos, dimethoate, and malathion in lettuce, but it could not be used to guarantee the safety of the same samples if methamidophos or phoxim residue was present. The sensitivity of the method was improved by the use of esterase purified by ammonium sulfate salting-out. The LODs obtained for methamidophos and phoxim with purified esterase were lower than the MRLs for these OPs in food. This is a very promising method for the detection of OP residues in vegetables using crude or purified esterase because of its cheapness, sensitivity, and convenience. PMID:22467368
NASA Astrophysics Data System (ADS)
Majd, Nayereh; Ghasemi, Zahra
2016-10-01
We have investigated a TPTQ state as an input state of a non-ideal ferromagnetic detectors. Minimal spin polarization required to demonstrate spin entanglement according to entanglement witness and CHSH inequality with respect to (w.r.t.) their two free parameters have been found, and we have numerically shown that the entanglement witness is less stringent than the direct tests of Bell's inequality in the form of CHSH in the entangled limits of its free parameters. In addition, the lower limits of spin detection efficiency fulfilling secure cryptographic key against eavesdropping have been derived. Finally, we have considered TPTQ state as an output of spin decoherence channel and the region of ballistic transmission time w.r.t. spin relaxation time and spin dephasing time has been found.
Wang, Fei-Xiang; Yuan, Ling; Huang, Jian-Guo
2013-06-01
In order to detect toxicants sensitively in water by phototaxity of Daphnia, we studied the influence of DC electric field on phototaxity of self-bred Daphnia carinata, a mono-clone with high phototaxity, and the changes of their phototaxity in response to Cr6+ and Hg2+ after the treatment of DC electric field. The result indicated that the treatment of DC electric field changed their phototaxical indexes from positive to negative as the electric density increased and the time prolonged. The criteria values that showed no sign of changes in the phototaxical index of Daphnia carinata were 0.01 mA for 5 min. However, the limit for detecting Cr6+ and Hg2+ by their phototaxical index decreased significantly after treatment with 0.01 mA/5 min. The detection limits were only 32 microg x L(-1) for Cr6+ and 4.2 microg x L(-1) for Hg2+ after this treatment, much lower than those without pretreatment (56 microg x L(-1) for Cr6+ and 5.6 microg x L(-1) for Hg2+, respectively). Therefore, appropriate DC electric field to pre-treat Daphnia could decrease the detection limit, widen the concentration range of detection, and increased the sensibilities in water monitoring.
Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert
2018-01-01
Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae. Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae, N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology. PMID:29425124
Higgins, Owen; Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert; Smith, Terry J
2018-02-09
Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae , Neisseria meningitidis and Haemophilus influenzae . Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae , N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology.
Dickson; Odom; Ducheneaux; Murray; Milofsky
2000-07-15
Despite the impressive separation efficiency afforded by capillary electrochromatography (CEC), the detection of UV-absorbing compounds following separation in capillary dimensions remains limited by the short path length (5-75 microm) through the column. Moreover, analytes that are poor chromophores present an additional challenge with respect to sensitive detection in CEC. This paper illustrates a new photochemical reaction detection scheme for CEC that takes advantage of the catalytic nature of type II photooxidation reactions. The sensitive detection scheme is selective toward molecules capable of photosensitizing the formation of singlet molecular oxygen (1O2). Following separation by CEC, UV-absorbing analytes promote groundstate 3O2 to an excited state (1O2) which reacts rapidly with tert-butyl-3,4,5-trimethylpyrrolecarboxylate, which is added to the running buffer. Detection is based on the loss of pyrrole. The reaction is catalytic in nature since one analyte molecule may absorb light many times, producing large amounts of 1O2. The detection limit for 9-acetylanthracene, following separation by CEC, is approximately 6 x 10(-9) M (S/N = 3). Optimization of the factors effecting the S/N for four model compounds is discussed.
Kurt, Hasan; Yüce, Meral; Hussain, Babar; Budak, Hikmet
2016-07-15
In this report, a dual-excitation sensing method was developed using aptamer-functionalized quantum dots and upconverting nanoparticles, exhibiting Stokes and anti-Stokes type excitation profiles, respectively. Conjugation of the aptamer-functionalized luminescent nanoparticles with the magnetic beads, comprising short DNA sequences that were partially complementary to the aptamer sequences, enabled facile separation of the analyte-free conjugates for fluorescent measurement. UV-Visible spectroscopy, Circular Dichroism spectroscopy, Dynamic Light Scattering and Polyacrylamide Gel Electrophoresis techniques were used to characterize the aptamer probes developed. The target-specific luminescent conjugates were applied for multiplex detection of model food pathogens, Salmonella typhimurium, and Staphylococcus aureus, in which the fluorescent emission spectra were obtained under UV excitation at 325nm for quantum dots and NIR excitation at 980nm for upconverting nanoparticles, respectively. The dual-excitation strategy was aimed to minimize cross-talk between the luminescent signals for multiplexed detection, and yielded limit of detection values of 16 and 28cfumL(-1) for Staphylococcus aureus, and Salmonella typhimurium, respectively. By employing a greater number of quantum dots and upconverting nanoparticles with non-overlapping fluorescent emissions, the proposed methodology might be exploited further to detect several analytes, simultaneously. Copyright © 2016 Elsevier B.V. All rights reserved.
Raboud, J M; Rae, S; Hogg, R S; Yip, B; Sherlock, C H; Harrigan, P R; O'Shaughnessy, M V; Montaner, J S
1999-10-01
Suppression of human immunodeficiency virus type 1 plasma virus load (PVL) to <20 copies/mL is associated with a longer virologic response after initiation of antiretroviral therapy. The relationship between duration of virologic response and PVL nadir according to a less sensitive assay was explored. When compared with subjects with a PVL nadir >500 copies/mL, the relative risks of PVL rising above 1000 copies/mL for participants in the INCAS trial and the British Columbia Drug Treatment Program with a PVL nadir below the limit of detection (LOD) were 0.04 (95% confidence interval [CI], 0.02-0.09) and 0.06 (95% CI, 0.03-0.12), respectively. The corresponding relative risks for persons with a detectable but not quantifiable PVL nadir were 0.25 (95% CI, 0.13-0.50) and 0.54 (95% CI, 0.25-1.19). The relative risks of virologic failure associated with a PVL nadir detectable but not quantifiable and a PVL nadir below the LOD were statistically different (P<.0001) in both data sets.
Li, Chuanliang; Wu, Yingfa; Qiu, Xuanbing; Wei, Jilin; Deng, Lunhua
2017-05-01
Wavelength modulation spectroscopy (WMS) combined with a multipass absorption cell has been used to measure a weak absorption line of carbon monoxide (CO) at 1.578 µm. A 0.95m Herriott-type cell provides an effective absorption path length of 55.1 m. The WMS signals from the first and second harmonic output of a lock-in amplifier (WMS-1 f and 2 f, respectively) agree with the Beer-Lambert law, especially at low concentrations. After boxcar averaging, the minimum detection limit achieved is 4.3 ppm for a measurement time of 0.125 s. The corresponding normalized detection limit is 84 ppm m Hz -1/2 . If the integrated time is increased to 88 s, the minimum detectable limit of CO can reach to 0.29 ppm based on an Allan variation analysis. The pressure-dependent relationship is validated after accounting for the pressure factor in data processing. Finally, a linear correlation between the WMS-2 f amplitudes and gas concentrations is obtained at concentration ratios less than 15.5%, and the accuracy is better than 92% at total pressure less than 62.7 Torr.
Lee, Hoonsoo; Kim, Moon S; Lohumi, Santosh; Cho, Byoung-Kwan
2018-06-05
Extensive research has been conducted on non-destructive and rapid detection of melamine in powdered foods in the last decade. While Raman and near-infrared hyperspectral imaging techniques have been successful in terms of non-destructive and rapid measurement, they have limitations with respect to measurement time and detection capability, respectively. Therefore, the objective of this study was to develop a mercury cadmium telluride (MCT)-based short-wave infrared (SWIR) hyperspectral imaging system and algorithm to detect melamine quantitatively in milk powder. The SWIR hyperspectral imaging system consisted of a custom-designed illumination system, a SWIR hyperspectral camera, a data acquisition module and a sample transfer table. SWIR hyperspectral images were obtained for melamine-milk samples with different melamine concentrations, pure melamine and pure milk powder. Analysis of variance and the partial least squares regression method over the 1000-2500 nm wavelength region were used to develop an optimal model for detection. The results showed that a melamine concentration as low as 50 ppm in melamine-milk powder samples could be detected. Thus, the MCT-based SWIR hyperspectral imaging system has the potential for quantitative and qualitative detection of adulterants in powder samples.
Wojtas, Jacek
2015-01-01
The paper presents one of the laser absorption spectroscopy techniques as an effective tool for sensitive analysis of trace gas species in human breath. Characterization of nitric oxide, carbonyl sulphide and ethane, and the selection of their absorption lines are described. Experiments with some biomarkers showed that detection of pathogenic changes at the molecular level is possible using this technique. Thanks to cavity enhanced spectroscopy application, detection limits at the ppb-level and short measurements time (<3 s) were achieved. Absorption lines of reference samples of the selected volatile biomarkers were probed using a distributed feedback quantum cascade laser and a tunable laser system consisting of an optical parametric oscillator and difference frequency generator. Setup using the first source provided a detection limit of 30 ppb for nitric oxide and 250 ppb for carbonyl sulphide. During experiments employing a second laser, detection limits of 0.9 ppb and 0.3 ppb were obtained for carbonyl sulphide and ethane, respectively. The conducted experiments show that this type of diagnosis would significantly increase chances for effective therapy of some diseases. Additionally, it offers non-invasive and real time measurements, high sensitivity and selectivity as well as minimizing discomfort for patients. For that reason, such sensors can be used in screening for early detection of serious diseases. PMID:26091398
Wojtas, Jacek
2015-06-17
The paper presents one of the laser absorption spectroscopy techniques as an effective tool for sensitive analysis of trace gas species in human breath. Characterization of nitric oxide, carbonyl sulphide and ethane, and the selection of their absorption lines are described. Experiments with some biomarkers showed that detection of pathogenic changes at the molecular level is possible using this technique. Thanks to cavity enhanced spectroscopy application, detection limits at the ppb-level and short measurements time (<3 s) were achieved. Absorption lines of reference samples of the selected volatile biomarkers were probed using a distributed feedback quantum cascade laser and a tunable laser system consisting of an optical parametric oscillator and difference frequency generator. Setup using the first source provided a detection limit of 30 ppb for nitric oxide and 250 ppb for carbonyl sulphide. During experiments employing a second laser, detection limits of 0.9 ppb and 0.3 ppb were obtained for carbonyl sulphide and ethane, respectively. The conducted experiments show that this type of diagnosis would significantly increase chances for effective therapy of some diseases. Additionally, it offers non-invasive and real time measurements, high sensitivity and selectivity as well as minimizing discomfort for patients. For that reason, such sensors can be used in screening for early detection of serious diseases.
Ag-Modified In2O3/ZnO Nanobundles with High Formaldehyde Gas-Sensing Performance
Fang, Fang; Bai, Lu; Song, Dongsheng; Yang, Hongping; Sun, Xiaoming; Sun, Hongyu; Zhu, Jing
2015-01-01
Ag-modified In2O3/ZnO bundles with micro/nano porous structures have been designed and synthesized with by hydrothermal method continuing with dehydration process. Each bundle consists of nanoparticles, where nanogaps of 10–30 nm are present between the nanoparticles, leading to a porous structure. This porous structure brings high surface area and fast gas diffusion, enhancing the gas sensitivity. Consequently, the HCHO gas-sensing performance of the Ag-modified In2O3/ZnO bundles have been tested, with the formaldehyde-detection limit of 100 ppb (parts per billion) and the response and recover times as short as 6 s and 3 s, respectively, at 300 °C and the detection limit of 100 ppb, response time of 12 s and recover times of 6 s at 100 °C. The HCHO sensing detect limitation matches the health standard limitation on the concentration of formaldehyde for indoor air. Moreover, the strategy to synthesize the nanobundles is just two-step heating and easy to scale up. Therefore, the Ag-modified In2O3/ZnO bundles are ready for industrialization and practical applications. PMID:26287205
Wilson, Peter M.; LaBonte, Melissa J.; Russell, Jared; Louie, Stan; Ghobrial, Andrew A.; Ladner, Robert D.
2011-01-01
Current methods for measuring deoxyribonucleoside triphosphates (dNTPs) employ reagent and labor-intensive assays utilizing radioisotopes in DNA polymerase-based assays and/or chromatography-based approaches. We have developed a rapid and sensitive 96-well fluorescence-based assay to quantify cellular dNTPs utilizing a standard real-time PCR thermocycler. This assay relies on the principle that incorporation of a limiting dNTP is required for primer-extension and Taq polymerase-mediated 5–3′ exonuclease hydrolysis of a dual-quenched fluorophore-labeled probe resulting in fluorescence. The concentration of limiting dNTP is directly proportional to the fluorescence generated. The assay demonstrated excellent linearity (R2 > 0.99) and can be modified to detect between ∼0.5 and 100 pmol of dNTP. The limits of detection (LOD) and quantification (LOQ) for all dNTPs were defined as <0.77 and <1.3 pmol, respectively. The intra-assay and inter-assay variation coefficients were determined to be <4.6% and <10%, respectively with an accuracy of 100 ± 15% for all dNTPs. The assay quantified intracellular dNTPs with similar results obtained from a validated LC–MS/MS approach and successfully measured quantitative differences in dNTP pools in human cancer cells treated with inhibitors of thymidylate metabolism. This assay has important application in research that investigates the influence of pathological conditions or pharmacological agents on dNTP biosynthesis and regulation. PMID:21576234
López-Calleja, Inés María; de la Cruz, Silvia; González, Isabel; García, Teresa; Martín, Rosario
2015-06-15
Two real-time polymerase chain reaction (PCR)-based assays for detection of walnut (Juglans regia) and pecan (Carya illinoinensis) traces in a wide range of processed foods are described here. The method consists on a real-time PCR assay targeting the ITS1 region, using a nuclease (TaqMan) probe labeled with FAM and BBQ. The method was positive for walnut and pecan respectively, and negative for all other heterologous plants and animals tested. Using a series of model samples with defined raw walnut in wheat flour and heat-treated walnut in wheat flour with a range of concentrations of 0.1-100,000 mg kg(-1), a practical detection limit of 0.1 mg kg(-1) of walnut content was estimated. Identical binary mixtures were done for pecan, reaching the same limit of detection of 0.1 mg kg(-1). The assay was successfully trialed on a total of 232 commercial foodstuffs. Copyright © 2015 Elsevier Ltd. All rights reserved.
CdZnTeS quantum dots based electrochemiluminescent image immunoanalysis.
Liang, Xiu-Li; Bao, Ning; Luo, Xiliang; Ding, Shou-Nian
2018-06-05
In this work, quaternary CdZnTeS quantum dots (QDs) with a particularly strong electrochemiluminescence (ECL) were synthesized as ECL signal labels. The strong ECL signals can be obtained at both cathode and anode with the ECL efficiencies of 19.78% and 1.62%, respectively. The sandwich-structured ECL immunosensors for the detection of alpha-fetoprotein (AFP) and cancer antigen 125 (CA125) were accomplished with direct ECL image analysis. Under optimal conditions, the QDs-based ECL image immunoanalysis possessed good linearity from 0.5 ng/mL to 20 ng/mL for AFP and from 20 U/mL to 500 U/mL for CA125 with the detection limit of 0.1 ng/mL and 6 U/mL, respectively (S/N = 3), and the lower detection limit obtained by photomultiplier tube were 0.1 fg/mL for AFP and 0.03 mU/mL for CA125 with the wide dynamic range from 0.5 fg/mL to 20 ng/mL and from 0.1 mU/mL to 500 U/mL, respectively (S/N = 3). Furthermore, the ECL immunoanalysis was evaluated with commercial enzyme-linked immunosorbent assay in human serum samples. The good results indicated that CdZnTeS QDs-based ECL biosensor has great potential for fast biomedical screening and multi-assays in clinical diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Heo, Seok; Yoo, Geum Joo; Choi, Ji Yeon; Park, Hyoung Joon; Park, Sung-Kwan; Baek, Sun Young
2016-11-01
A novel, stable, simple and specific ultra-performance liquid chromatography method with ultraviolet detection (205 nm) for the simultaneous analysis of 25 anti-hypertensive substances was developed. The method was validated according to the International Conference of Harmonisation guidelines with respect to linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ) and stability. From the ultra-performance liquid chromatography results, we identified the LOD and LOQ of solid samples to be 0.20-1.00 and 0.60-3.00 μg ml -1 , respectively, while those of liquid samples were 0.30-1.20 and 0.90-3.60 μg ml -1 , respectively. The linearity exceeded 0.9999, and the intra- and inter-day precisions were 0.15-6.48% and 0.28-8.67%, respectively. The intra- and inter-day accuracies were 82.25-111.42% and 80.70-115.64%, respectively, and the stability was lower than 12.9% (relative standard deviation). This method was applied to the monitoring of 97 commercially available dietary supplements obtained in Korea, such as pills, soft capsules, hard capsules, liquids, powders and tablets. The proposed method is accurate, precise and of high quality, and can be used for the routine, reproducible analysis and control of 25 anti-hypertensive substances in various dietary supplements. The work presented herein may help to prevent incidents related to food adulteration and restrict the illegal food market.
Sodium benzoate and potassium sorbate preservatives in Iranian doogh.
Zamani Mazdeh, F; Esmaeili Aftabdari, F; Moradi-Khatoonabadi, Z; Shaneshin, M; Torabi, P; Shams Ardekani, M R; Hajimahmoodi, M
2014-01-01
Sodium benzoate and potassium sorbate are two common preservatives used in Iran, yet use of these preservatives in doogh (Iranian dairy-based drink) is forbidden according to national standards. The aim of this study was to consider the presence of these preservatives in doogh by high-performance liquid chromatography with UV detection (HPLC-UV). The method was performed using a C18 column and detection at 225 nm. The mobile phase contained ammonium acetate buffer (pH = 4.2) and acetonitrile (80:20 v/v). The survey included 130 samples of doogh for identification and quantification of the named preservatives. All samples contained sodium benzoate, but potassium sorbate was detected in only 13% of them. The means of benzoate and sorbate were 21.3 ± 2.7 and 13.3 ± 39.6 mg kg(-1), respectively. The limits of detection were 2 and 40 ng g(-1) for benzoate and sorbate, respectively. Results indicate that sodium benzoate may occur in doogh naturally.
Hassan, Ahmed Sheikh; Sapin, Anne; Ubrich, Nathalie; Maincent, Philippe; Bolzan, Claire; Leroy, Pierre
2008-10-01
A simple and sensitive high-performance liquid chromatography (HPLC) assay applied to the measurement of ibuprofen in rat plasma has been developed. Two parameters have been investigated to improve ibuprofen detectability using fluorescence detection: variation of mobile phase pH and the use of beta-cyclodextrin (beta-CD). Increasing the pH value from 2.5 to 6.5 and adding 5 mM beta-CD enhanced the fluorescence signal (lambda(exc) = 224 nm; lambda(em) = 290 nm) by 2.5 and 1.3-fold, respectively, when using standards. In the case of plasma samples, only pH variation significantly lowered detection and quantification limits, down to 10 and 35 ng/mL, respectively. Full selectivity was obtained with a single step for plasma treatment, that is, protein precipitation with acidified acetonitrile. The validated method was applied to a pharmacokinetic study of ibuprofen encapsulated in microspheres and subcutaneously administered to rats.
NASA Astrophysics Data System (ADS)
Leepheng, Piyawan; Suramitr, Songwut; Phromyothin, Darinee
2017-09-01
The schiff base was synthesized by 2,5-thiophenedicarboxaldehyde and 1,2,4-thiadiazole-3,5-diamine with condensation method. There was modified on carbon paste electrode (CPE) and Printed circuit board (PCB) gold electrode for determination silver ion. The schiff base modified electrodes was characterized by atomic force microscopy (AFM) and scanning electron microscopy (SEM), respectively. The electrochemical study was reported by cyclic voltammetry method and impedance spectroscopy using modified electrode as working electrode, platinum wire and Ag/AgCl as counter electrode and reference electrode, respectively. The modified electrodes have suitable detection for Ag+. The determination of silver ions using the modified electrodes depended linearly on Ag+ concentration in the range 1×10-10 M to 1×10-7 M, with cyclic voltammetry sensitivity were 2.51×108 μAM-1 and 1.88×108 μAM-1 for PCB gold electrode and CPE electrode, respectively, limits of detection were 5.33×10-9 M and 1.99×10-8 M for PCB gold electrode and CPE electrode, respectively. The modified electrodes have high accuracy, inexpensive and can applied to detection Ag+ in real samples.
Blank, Brian S. N.; Meenhorst, Pieter L.; Mulder, Jan Willem; Weverling, Gerrit Jan; Putter, Hein; Pauw, Wouter; van Dijk, Willemien C.; Smits, Paul; Lie-A-Ling, Sonja; Reiss, Peter; Lange, Joep M. A.
2000-01-01
In the present prospective study, five blood tests for detection of human cytomegalovirus (HCMV), nucleic acid sequence-based amplification (NASBA) for detection of early (immediate-early antigen) and late (pp67) mRNA, PCR for detection of HCMV DNA (DNA PCR), culture, and pp65 antigenemia assay, and culture and DNA PCR of urine and throat swab specimens were compared for their abilities to predict the development of disease caused by HCMV (HCMV disease). Of 101 human immunodeficiency virus (HIV)-infected patients with ≤100 CD4+ lymphocytes per mm3, 25 patients developed HCMV disease. The pp65 antigenemia assay (sensitivity, 50%; specificity, 89%) and DNA PCR of blood (sensitivity, 69%; specificity, 75%) were most accurate in predicting the development of HCMV disease within the next 12 months. Both blood culture and late pp67 mRNA NASBA had high specificities (91 and 90%, respectively) but low sensitivities (25 and 13%, respectively). The sensitivities of urine culture, DNA PCR, throat swab specimen culture, DNA PCR, and NASBA of blood for detection of the immediate-early antigen were 73, 87, 53, 67, and 63%, respectively, and the specificities were 58, 46, 76, 60, and 72%, respectively. The positive predictive values of all tests however, were low and did not exceed 50%. In conclusion, virological screening by these qualitative assays for detection of HCMV is of limited value for prediction of the development of HCMV disease in HIV-infected patients. PMID:10655346
Mu, Luye; Droujinine, Ilia A; Rajan, Nitin K; Sawtelle, Sonya D; Reed, Mark A
2014-09-10
We demonstrate the versatility of Al2O3-passivated Si nanowire devices ("nanoribbons") in the analysis of enzyme-substrate interactions via the monitoring of pH change. Our approach is shown to be effective through the detection of urea in phosphate buffered saline (PBS), and penicillinase in PBS and urine, at limits of detection of <200 μM and 0.02 units/mL, respectively. The ability to extract accurate enzyme kinetics and the Michaelis-Menten constant (Km) from the acetylcholine-acetylcholinesterase reaction is also demonstrated.
Main-belt comets in the Palomar Transient Factory survey - I. The search for extendedness
NASA Astrophysics Data System (ADS)
Waszczak, A.; Ofek, E. O.; Aharonson, O.; Kulkarni, S. R.; Polishook, D.; Bauer, J. M.; Levitan, D.; Sesar, B.; Laher, R.; Surace, J.; PTF Team
2013-08-01
Cometary activity in main-belt asteroids probes the ice content of these objects and provides clues to the history of volatiles in the inner Solar system. We search the Palomar Transient Factory survey to derive upper limits on the population size of active main-belt comets (MBCs). From data collected from 2009 March through 2012 July, we extracted ˜2 million observations of ˜220 thousand known main-belt objects (40 per cent of the known population, down to ˜1-km diameter) and discovered 626 new objects in multinight linked detections. We formally quantify the `extendedness' of a small-body observation, account for systematic variation in this metric (e.g. due to on-sky motion) and evaluate this method's robustness in identifying cometary activity using observations of 115 comets, including two known candidate MBCs and six newly discovered non-MBCs (two of which were originally designated as asteroids by other surveys). We demonstrate a 66 per cent detection efficiency with respect to the extendedness distribution of the 115 sampled comets, and a 100 per cent detection efficiency with respect to extendedness levels greater than or equal to those we observed in the known candidate MBCs P/2010 R2 (La Sagra) and P/2006 VW139. Using a log-constant prior, we infer 95 per cent confidence upper limits of 33 and 22 active MBCs (per million main-belt asteroids down to ˜1-km diameter), for detection efficiencies of 66 and 100 per cent, respectively. In a follow-up to this morphological search, we will perform a photometric (disc-integrated brightening) search for MBCs.
NASA Astrophysics Data System (ADS)
Hamedan, N. A.; Hasan, S.; Zaki, H. M.; Alias, N. Z.
2017-02-01
A novel receptor, designed with a combination of oxygen (O), nitrogen (N) and sulfur (S) -binding sites for metal ions was synthesized. Ortho (A), meta (B) and para (C) bearing benzoyl thiourea were designed and synthesized with triamine group to apply as colorimetric chemosensors for detection of Cu2+. The structure was confirmed by characterized the compound using Elemental analysis, Fourier Infrared (FTIR) and proton Nuclear Magnetic Resonance (1H NMR) spectroscopy. Functional groups of C=O, N-H, C=N and C=S were found at 1677 cm-1, 3240 cm-1, 1591 cm-1, 1024 cm-1 respectively while 1H NMR shows peaks of alkane (CH2), benzene (Ar-H), CONH, CSNH at 3.68 - 4.14, 7.16 - 7.86, 8.74, and 9.2 respectively. Elemental analysis for A, B and C C20H21N5O2S2Br2 found was compatible with the expected theoretical calculation. For an application, all of these three sensors showed excellent colorimetric specific selectivity and high sensitivity for Cu2+ in acetonitrile/water binary solutions, so only A was selected for further studies towards sensitivity. When Cu2+ was added to the solution of A, a dramatic color change from yellow to green, while other cations Fe2+, Zn2+, Ni2+, Co2+, Cr3+ and Mn2+ did not interfere with the recognition process for Cu2+. The detection limit of the sensor C toward Cu2+ was 1.15 x 10-5 M, which is less sensitive that sensor A and B with a detection limit of 6.2 x 10-6 M and 1.5 x 10-6 M respectively. This indicated that the sensor A and B might be useful as an efficient chemical sensor.
Roth, Virginia R; Mitchell, Robyn; Vachon, Julie; Alexandre, Stéphanie; Amaratunga, Kanchana; Smith, Stephanie; Vearncombe, Mary; Davis, Ian; Mertz, Dominik; Henderson, Elizabeth; John, Michael; Johnston, Lynn; Lemieux, Camille; Pelude, Linda; Gravel, Denise
2017-02-01
BACKGROUND Hip and knee arthroplasty infections are associated with considerable healthcare costs. The merits of reducing the postoperative surveillance period from 1 year to 90 days have been debated. OBJECTIVES To report the first pan-Canadian hip and knee periprosthetic joint infection (PJI) rates and to describe the implications of a shorter (90-day) postoperative surveillance period. METHODS Prospective surveillance for infection following hip and knee arthroplasty was conducted by hospitals participating in the Canadian Nosocomial Infection Surveillance Program (CNISP) using standard surveillance definitions. RESULTS Overall hip and knee PJI rates were 1.64 and 1.52 per 100 procedures, respectively. Deep incisional and organ-space hip and knee PJI rates were 0.96 and 0.71, respectively. In total, 93% of hip PJIs and 92% of knee PJIs were identified within 90 days, with a median time to detection of 21 days. However, 11%-16% of deep incisional and organ-space infections were not detected within 90 days. This rate was reduced to 3%-4% at 180 days post procedure. Anaerobic and polymicrobial infections had the shortest median time from procedure to detection (17 and 18 days, respectively) compared with infections due to other microorganisms, including Staphylococcus aureus. CONCLUSIONS PJI rates were similar to those reported elsewhere, although differences in national surveillance systems limit direct comparisons. Our results suggest that a postoperative surveillance period of 90 days will detect the majority of PJIs; however, up to 16% of deep incisional and organ-space infections may be missed. Extending the surveillance period to 180 days could allow for a better estimate of disease burden. Infect Control Hosp Epidemiol 2017;38:147-153.
Early Detection of Physical Activity for People With Type 1 Diabetes Mellitus.
Dasanayake, Isuru S; Bevier, Wendy C; Castorino, Kristin; Pinsker, Jordan E; Seborg, Dale E; Doyle, Francis J; Dassau, Eyal
2015-06-30
Early detection of exercise in individuals with type 1 diabetes mellitus (T1DM) may allow changes in therapy to prevent hypoglycemia. Currently there is limited experience with automated methods that detect the onset and end of exercise in this population. We sought to develop a novel method to quickly and reliably detect the onset and end of exercise in these individuals before significant changes in blood glucose (BG) occur. Sixteen adults with T1DM were studied as outpatients using a diary, accelerometer, heart rate monitor, and continuous glucose monitor for 2 days. These data were used to develop a principal component analysis based exercise detection method. Subjects also performed 60 and 30 minute exercise sessions at 30% and 50% predicted heart rate reserve (HRR), respectively. The detection method was applied to the exercise sessions to determine how quickly the detection of start and end of exercise occurred relative to change in BG. Mild 30% HRR and moderate 50% HRR exercise onset was identified in 6 ± 3 and 5 ± 2 (mean ± SD) minutes, while completion was detected in 3 ± 8 and 6 ± 5 minutes, respectively. BG change from start of exercise to detection time was 1 ± 6 and -1 ± 3 mg/dL, and, from the end of exercise to detection time was 6 ± 4 and -17 ± 13 mg/dL, respectively, for the 2 exercise sessions. False positive and negative ratios were 4 ± 2% and 21 ± 22%. The novel method for exercise detection identified the onset and end of exercise in approximately 5 minutes, with an average BG change of only -6 mg/dL. © 2015 Diabetes Technology Society.
Soh, Jun Hui; Lin, Yiyang; Rana, Subinoy; Ying, Jackie Y; Stevens, Molly M
2015-08-04
A versatile and sensitive colorimetric assay that allows the rapid detection of small-molecule targets using the naked eye is demonstrated. The working principle of the assay integrates aptamer-target recognition and the aptamer-controlled growth of gold nanoparticles (Au NPs). Aptamer-target interactions modulate the amount of aptamer strands adsorbed on the surface of aptamer-functionalized Au NPs via desorption of the aptamer strands when target molecules bind with the aptamer. Depending on the resulting aptamer coverage, Au NPs grow into morphologically varied nanostructures, which give rise to different colored solutions. Au NPs with low aptamer coverage grow into spherical NPs, which produce red-colored solutions, whereas Au NPs with high aptamer coverage grow into branched NPs, which produce blue-colored solutions. We achieved visible colorimetric response and nanomolar detection limits for the detection of ochratoxin A (1 nM) in red wine samples, as well as cocaine (1 nM) and 17β-estradiol (0.2 nM) in spiked synthetic urine and saliva, respectively. The detection limits were well within clinically and physiologically relevant ranges, and below the maximum food safety limits. The assay is highly sensitive, specific, and able to detect an array of analytes rapidly without requiring sophisticated equipment, making it relevant for many applications, such as high-throughput drug and clinical screening, food sampling, and diagnostics. Furthermore, the assay is easily adapted as a chip-based platform for rapid and portable target detection.
NASA Astrophysics Data System (ADS)
Haider, A. F. M. Y.; Hedayet Ullah, M.; Khan, Z. H.; Kabir, Firoza; Abedin, K. M.
2014-03-01
LIBS technique coupled with adsorption has been applied for the efficient detection of arsenic in liquid. Several adsorbents like tea leaves, bamboo slice, charcoal and zinc oxide have been used to enable sensitive detection of arsenic presence in water using LIBS. Among these, zinc oxide and charcoal show the better results. The detection limits for arsenic in water were 1 ppm and 8 ppm, respectively, when ZnO and charcoal were used as adsorbents of arsenic. To date, the determination of 1 ppm of As in water is the lowest concentration of detected arsenic in water by the LIBS technique. The detection limit of As was lowered to even less than 100 ppb by a combination of LIBS technique, adsorption by ZnO and concentration enhancement technique. Using the combination of these three techniques the ultimate concentration of arsenic was found to be 0.083 ppm (83 ppb) for arsenic polluted water collected from a tube-well of Farajikandi union (longitude 90.64°, latitude 23.338° north) of Matlab Upozila of Chandpur district in Bangladesh. This result compares fairly well with the finding of arsenic concentration of 0.078 ppm in the sample by the AAS technique at the Bangladesh Council of Scientific and Industrial Research (BCSIR) lab. Such a low detection limit (1 ppm) of trace elements in liquid matrix has significantly enhanced the scope of LIBS as an analytical tool.
Functionalized gold nanoparticles for the detection of arsenic in water.
Domínguez-González, R; González Varela, L; Bermejo-Barrera, P
2014-01-01
Gold nanoparticles are attractive as sensing materials because of their size and shape are related with their optical properties. The color change produced by the aggregation of functionalized AuNPs allows the detection of arsenic at low levels. A simple, cheap and fast analytical procedure to perform arsenic determination using functionalized gold nanoparticles (AuNPs) and VIS spectrometry as a detection technique is studied. Three different synthesis procedures to obtain the AuNPs and two different functionalization modes were studied. AuNPs functionalized with GSH-DTT-CYs-PDCA were selected as the most adequate. The correlation between the decrease in the absorbance signal and the arsenic concentration was good in the 2-20 µg l(-1)interval. Repeatability, expressed as average of RSD (%), obtained for the different arsenic concentrations studied was 0.6%. The average value of the analytical recovery was 99.7%. The detection and quantifications limits were 2.5 and 8.4 µg l(-1) respectively. These limits are sufficient to detect World Health Organization's guideline value of 10 µg l(-1). © 2013 Published by Elsevier B.V.
Suspended Microchannel Resonators for Ultralow Volume Universal Detection
Son, Sungmin; Grover, William H.; Burg, Thomas P.; Manalis, Scott R.
2008-01-01
Universal detectors that maintain high sensitivity as the detection volume is reduced to the subnanoliter scale can enhance the utility of miniaturized total analysis systems (μ-TAS). Here the unique scaling properties of the suspended microchannel resonator (SMR) are exploited to show universal detection in a 10 pL analysis volume with a density detection limit of ∼1 μg/cm3 (10 Hz bandwidth) and a dynamic range of 6 decades. Analytes with low UV extinction coefficients such as polyethylene glycol (PEG) 8 kDa, glucose, and glycine are measured with molar detection limits of 0.66, 13.5, and 31.6 μM, respectively. To demonstrate the potential for real-time monitoring, gel filtration chromatography was used to separate different molecular weights of PEG as the SMR acquired a chromatogram by measuring the eluate density. This work suggests that the SMR could offer a simple and sensitive universal detector for various separation systems from liquid chromatography to capillary electrophoresis. Moreover, since the SMR is itself a microfluidic channel, it can be directly integrated into μ-TAS without compromising overall performance. PMID:18489125
Simple detection of residual enrofloxacin in meat products using microparticles and biochips.
Ha, Mi-Sun; Chung, Myung-Sub; Bae, Dong-Ho
2016-05-01
A simple and sensitive method for detecting enrofloxacin, a major veterinary fluoroquinolone, was developed. Monoclonal antibody specific for enrofloxacin was immobilised on a chip and fluorescent dye-labelled microparticles were covalently bound to the enrofloxacin molecules. Enrofloxacin in solution competes with the microparticle-immobilised enrofloxacin (enroMPs) to bind to the antibody on the chip. The presence of enrofloxacin was verified by detecting the fluorescence of enrofloxacin-bound microparticles. Under optimum conditions, a high dynamic range was achieved at enrofloxacin concentrations ranging from 1 to 1000 μg kg(-1). The limits of detection and quantification for standard solutions were 5 and 20 μg kg(-1) respectively, which are markedly lower than the maximum residue limit. Using simple extraction methods, recoveries from fortified beef, pork and chicken samples were 43.4-62.3%. This novel method also enabled approximate quantification of enrofloxacin concentration: the enroMP signal intensity decreased with increasing enrofloxacin concentration. Because of its sensitivity, specificity, simplicity and rapidity, the method described herein will facilitate the detection and approximate quantification of enrofloxacin residues in foods in a high-throughput manner.
Residual dynamic and risk assessment of dimethomorph in Swiss chard grown at two different sites.
Kabir, Md Humayun; Abd El-Aty, A M; Rahman, Md Musfiqur; Chung, Hyung Suk; Lee, Han Sol; Kim, Mi-Ra; Chang, Byung-Joon; Wang, Jing; Shin, Ho-Chul; Shim, Jae-Han
2018-02-01
Residue analysis of dimethomorph in Swiss chard cultivated at two different locations under greenhouse conditions was conducted using high-performance liquid chromatography-ultraviolet detection and confirmed by tandem mass spectrometry. The randomly collected samples (over 14 days) were extracted with acetonitrile and purified using a Florisil solid-phase extraction cartridge. Linearity over a concentration range of 0.05-50.0 mg/L had an excellent coefficient of determination of 0.9996. Recovery rate ranged from 82.98 to 95.43% with relative standard deviations ≤5.12% and limits of detection and quantification of 0.003 and 0.01 mg/kg, respectively. The initial deposits [day 0 (2 h post-application)] were considerably lower (7.57 and 8.55 mg/kg for sites 1 and 2, respectively) than the maximum residue limit (30 mg/kg) set by the Korean Ministry of Food and Drug Safety. The dissipation half-life was approximately the same, being 5.0 and 5.1 days for sites 1 and 2, respectively. Risk assessment estimated as acceptable daily intake revealed a value of 0.084 or 0.094% (day 0) and 0.014% (10 days post-application), for sites 1 and 2, respectively. The values indicated that dimethomorph can be safely used on Swiss chard, with no hazardous effects expected for Korean consumers. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Ye, Yingjie; Chen, Jin; Ding, Qianqian; Lin, Dongyue; Dong, Ronglu; Yang, Liangbao; Liu, Jinhuai
2013-06-01
Ag-coated sea-urchin-like Fe3O4@C core-shell particles can be synthesized by a facile one-step solvothermal method, followed by deposition of high-density Ag nanoparticles onto the carbon surface through an in situ growth process, respectively. The as-synthesized Ag-coated Fe3O4@C particles can be used as a surface-enhanced Raman scattering (SERS) substrate holding reproducible properties under an external magnetic force. The magnetic function of the particles allows concentrating the composite particles into small spatial regions, which can be exploited to decrease the amount of material per analysis while improving its SERS detection limit. In contrast to the traditional SERS substrates, the present Fe3O4@C@Ag particles hold the advantages of enrichment of organic pollutants for improving SERS detection limit and recycled utilization.Ag-coated sea-urchin-like Fe3O4@C core-shell particles can be synthesized by a facile one-step solvothermal method, followed by deposition of high-density Ag nanoparticles onto the carbon surface through an in situ growth process, respectively. The as-synthesized Ag-coated Fe3O4@C particles can be used as a surface-enhanced Raman scattering (SERS) substrate holding reproducible properties under an external magnetic force. The magnetic function of the particles allows concentrating the composite particles into small spatial regions, which can be exploited to decrease the amount of material per analysis while improving its SERS detection limit. In contrast to the traditional SERS substrates, the present Fe3O4@C@Ag particles hold the advantages of enrichment of organic pollutants for improving SERS detection limit and recycled utilization. Electronic supplementary information (ESI) available: Additional XRD patterns and SEM images of Fe3O4@C particles, SERS spectra of 4-ATP and 4-MPY using Fe3O4@C@Ag particles as the active substrates, magnetic behaviour of Fe3O4@C and Fe3O4@C@Ag particles. See DOI: 10.1039/c3nr01273e
pH-Triggered Molecular Alignment for Reproducible SERS Detection via an AuNP/Nanocellulose Platform
Wei, Haoran; Vikesland, Peter J.
2015-01-01
The low affinity of neutral and hydrophobic molecules towards noble metal surfaces hinders their detection by surface-enhanced Raman spectroscopy (SERS). Herein, we present a method to enhance gold nanoparticle (AuNP) surface affinity by lowering the suspension pH below the analyte pKa. We developed an AuNP/bacterial cellulose (BC) nanocomposite platform and applied it to two common pollutants, carbamazepine (CBZ) and atrazine (ATZ) with pKa values of 2.3 and 1.7, respectively. Simple mixing of the analytes with AuNP/BC at pH < pKa resulted in consistent electrostatic alignment of the CBZ and ATZ molecules across the nanocomposite and highly reproducible SERS spectra. Limits of detection of 3 nM and 11 nM for CBZ and ATZ, respectively, were attained. Tests with additional analytes (melamine, 2,4-dichloroaniline, 4-chloroaniline, 3-bromoaniline, and 3-nitroaniline) further illustrate that the AuNP/BC platform provides reproducible analyte detection and quantification while avoiding the uncontrolled aggregation and flocculation of AuNPs that often hinder low pH detection. PMID:26658696
pH-Triggered Molecular Alignment for Reproducible SERS Detection via an AuNP/Nanocellulose Platform
NASA Astrophysics Data System (ADS)
Wei, Haoran; Vikesland, Peter J.
2015-12-01
The low affinity of neutral and hydrophobic molecules towards noble metal surfaces hinders their detection by surface-enhanced Raman spectroscopy (SERS). Herein, we present a method to enhance gold nanoparticle (AuNP) surface affinity by lowering the suspension pH below the analyte pKa. We developed an AuNP/bacterial cellulose (BC) nanocomposite platform and applied it to two common pollutants, carbamazepine (CBZ) and atrazine (ATZ) with pKa values of 2.3 and 1.7, respectively. Simple mixing of the analytes with AuNP/BC at pH < pKa resulted in consistent electrostatic alignment of the CBZ and ATZ molecules across the nanocomposite and highly reproducible SERS spectra. Limits of detection of 3 nM and 11 nM for CBZ and ATZ, respectively, were attained. Tests with additional analytes (melamine, 2,4-dichloroaniline, 4-chloroaniline, 3-bromoaniline, and 3-nitroaniline) further illustrate that the AuNP/BC platform provides reproducible analyte detection and quantification while avoiding the uncontrolled aggregation and flocculation of AuNPs that often hinder low pH detection.
Qiu, Huazhang; Wu, Namei; Zheng, Yanjie; Chen, Min; Weng, Shaohuang; Chen, Yuanzhong; Lin, Xinhua
2015-01-01
A robust and versatile signal-on fluorescence sensing strategy was developed to provide label-free detection of various target analytes. The strategy used SYBR Green I dye and graphene oxide as signal reporter and signal-to-background ratio enhancer, respectively. Multidrug resistance protein 1 (MDR1) gene and mercury ion (Hg2+) were selected as target analytes to investigate the generality of the method. The linear relationship and specificity of the detections showed that the sensitive and selective analyses of target analytes could be achieved by the proposed strategy with low detection limits of 0.5 and 2.2 nM for MDR1 gene and Hg2+, respectively. Moreover, the strategy was used to detect real samples. Analytical results of MDR1 gene in the serum indicated that the developed method is a promising alternative approach for real applications in complex systems. Furthermore, the recovery of the proposed method for Hg2+ detection was acceptable. Thus, the developed label-free signal-on fluorescence sensing strategy exhibited excellent universality, sensitivity, and handling convenience. PMID:25565810
Sayago, Isabel; Matatagui, Daniel; Fernández, María Jesús; Fontecha, José Luis; Jurewicz, Izabela; Garriga, Rosa; Muñoz, Edgar
2016-02-01
A Love-wave device with graphene oxide (GO) as sensitive layer has been developed for the detection of chemical warfare agent (CWA) simulants. Sensitive films were fabricated by airbrushing GO dispersions onto Love-wave devices. The resulting Love-wave sensors detected very low CWA simulant concentrations in synthetic air at room temperature (as low as 0.2 ppm for dimethyl-methylphosphonate, DMMP, a simulant of sarin nerve gas, and 0.75 ppm for dipropylene glycol monomethyl ether, DPGME, a simulant of nitrogen mustard). High responses to DMMP and DPGME were obtained with sensitivities of 3087 and 760 Hz/ppm respectively. Very low limit of detection (LOD) values (9 and 40 ppb for DMMP and DPGME, respectively) were calculated from the achieved experimental data. The sensor exhibited outstanding sensitivity, good linearity and repeatability to all simulants tested. The detection mechanism is here explained in terms of hydrogen bonding formation between the tested CWA simulants and GO. Copyright © 2015 Elsevier B.V. All rights reserved.
Patil, R; Shankar, K M; Kumar, B T N; Kulkarni, A; Patil, P; Moger, N
2013-09-01
A flow-through immunoassay (FTA), an improved version of immunodot, was developed using a nitrocellulose membrane baked onto adsorbent pads enclosed in a plastic cassette to detect white spot syndrome virus (WSSV) in shrimp. Sharp purple dots developed with WSSV against the white background of the nitrocellulose membrane. The detection limits of WSSV by the FTA and immunodot were 0.312 and 1.2 μg mL(-1) crude WSSV protein, respectively. The FTA could be completed in 8-10 min compared with 90 min for immunodot. The FTA was 100 times more sensitive than 1-step polymerase chain reaction (PCR) and in between that of the 1- and 2-step PCR protocol recommended by the Office of International Epizootics (OIE). In experimental, orally infected shrimp post-larvae, WSSV was first detected 14, 16 and 18 h post-infection (hpi) by FTA, immunodot and one-step PCR, respectively. The FTA detected WSSV 2 and 4 h earlier than immunodot and one-step PCR, respectively. The FTA was more sensitive (25/27) than one-step PCR (23/27) and immunodot (23/27) for the detection of WSSV from white spot disease outbreak ponds. The reagent components of the FTA were stable giving expected results for 6 m at 4-8 °C. The FTA is available as a rapid test kit called 'RapiDot' for the early detection of WSSV under field conditions. © 2013 John Wiley & Sons Ltd.
Cadiou, Erwan; Mammez, Dominique; Dherbecourt, Jean-Baptiste; Gorju, Guillaume; Pelon, Jacques; Melkonian, Jean-Michel; Godard, Antoine; Raybaut, Myriam
2017-10-15
We report on the capability of a direct detection differential absorption lidar (DIAL) for range resolved and integrated path (IPDIAL) remote sensing of CO 2 in the atmospheric boundary layer (ABL). The laser source is an amplified nested cavity optical parametric oscillator (NesCOPO) emitting approximately 8 mJ at the two measurement wavelengths selected near 2050 nm. Direct detection atmospheric measurements are taken from the ground using a 30 Hz frequency switching between emitted wavelengths. Results show that comparable precision measurements are achieved in DIAL and IPDIAL modes (not better than a few ppm) on high SNR targets such as near range ABL aerosol and clouds, respectively. Instrumental limitations are analyzed and degradation due to cloud scattering variability is discussed to explain observed DIAL and IPDIAL limitations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allahverdi, Rouzbeh; Gao, Yu; Knockel, Bradley
In this paper, we study indirect detection signals from solar annihilation of dark matter (DM) particles into light right-handed (RH) neutrinos with a mass in a 1–5 GeV range. These RH neutrinos can have a sufficiently long lifetime to allow them to decay outside the Sun, and their delayed decays can result in a signal in gamma rays from the otherwise “dark” solar direction, and also a neutrino signal that is not suppressed by the interactions with solar medium. We find that the latest Fermi-LAT and IceCube results place limits on the gamma ray and neutrino signals, respectively. Combined photonmore » and neutrino bounds can constrain the spin-independent DM-nucleon elastic scattering cross section better than direct detection experiments for DM masses from 200 GeV up to several TeV. Finally, the bounds on spin-dependent scattering are also much tighter than the strongest limits from direct detection experiments.« less
Sorbic and benzoic acid in non-preservative-added food products in Turkey.
Cakir, Ruziye; Cagri-Mehmetoglu, Arzu
2013-01-01
Sorbic acid (SA) and benzoic acid (BA) were determined in yoghurt, tomato and pepper paste, fruit juices, chocolates, soups and chips in Turkey by using high-pressure liquid chromatography (HPLC). Levels were compared with Turkish Food Codex limits. SA was detected only in 2 of 21 yoghurt samples, contrary to BA, which was found in all yoghurt samples but one, ranging from 10.5 to 159.9 mg/kg. Both SA and BA were detected also in 3 and 6 of 23 paste samples in a range of 18.1-526.4 and 21.7-1933.5 mg/kg, respectively. Only 1 of 23 fruit juices contained BA. SA was not detected in any chips, fruit juice, soup, or chocolate sample. Although 16.51% of the samples was not compliant with the Turkish Food Codex limits, estimated daily intake of BA or SA was below the acceptable daily intake.
Sultana, Najma; Arayne, M Saeed; Ali, Saeeda Nadir
2013-10-01
A highly sensitive LC method with UV detection has been developed for the simultaneous determination of coadministered drugs captopril, piroxicam, and amlodipine in bulk drug, pharmaceutical formulations, and human serum at the isosbestic point (235 nm) and at individual λmax (220, 255, and 238 nm, respectively) by programming the detector with time to match the individual analyte's chromophore, which enhanced the sensitivity with linear range. The assay involved an isocratic elution of analytes on a Bondapak C18 (10 μm, 25 × 0.46 cm) column at ambient temperature using a mobile phase of methanol/water 80:20 at pH 2.9 and a flow rate of 1.0 mL/min. Linearity was found to be 0.25-25, 0.10-6.0, and 0.20-13.0 μg/mL with correlation coefficient >0.998 and detection limits of 7.39, 3.90, and 9.38 ng/mL, respectively, whereas calibration curves for wavelength-programmed analysis were 0.10-6.0, 0.04-2.56, and 0.10-10.0 μg/mL with correlation coefficient >0.998 and detection limits of 5.79, 2.68, and 3.87 ng/mL, respectively. All the validated parameters were in the acceptable range. The recovery of drugs was 99.32-100.39 and 98.65-101.96% in pharmaceutical formulation and human serum, respectively, at the isosbestic point and at individual λmax . This method is applicable for the analysis of drugs in bulk drug, tablets, serum, and in clinical samples without interference of excipients or endogenous serum components. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav
2009-05-01
Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.
NASA Astrophysics Data System (ADS)
Yan, Zhengquan; Zhao, Qi; Wen, Meijun; Hu, Lei; Zhang, Xuezhong; You, Jinmao
2017-11-01
A novel polydentate ligand chromophore, 3,6-di-(N-ethyl-N-ethoxyl phenylazo) acridine (EEPA), was identified and synthesized. After its structure was characterized by FTIR, 1H NMR, mass spectra and element analyses, it was noted to find that there was a simultaneously colorimetric response to Ag+ and Fe3 + accompanying with different color changes, i.e., from brown to light purple for Ag+ and further to purple-red for Fe3 +, respectively. Their different action mechanisms, a 1:2 complex mode for EEPA-Ag+ and 1:1 for EEPA-Fe3 +, were investigated and confirmed by means of Job's plot and theoretical calculation. EEPA would be a potential colorimetric chemo-dosimeter for simultaneous detection of Ag+ and Fe3 + with the detection limits of 1.6 nmol·L- 1 and 69 nmol·L- 1, respectively.
NASA Astrophysics Data System (ADS)
Chen, Kuan-Yu; Yang, Thomas C.; Chang, Sarah Y.
2012-06-01
A novel method for the determination of macrolide antibiotics using dispersive liquid-liquid microextraction coupled to surface-assisted laser desorption/ionization mass spectrometric detection was developed. Acetone and dichloromethane were used as the disperser solvent and extraction solvent, respectively. A mixture of extraction solvent and disperser solvent were rapidly injected into a 1.0 mL aqueous sample to form a cloudy solution. After the extraction, macrolide antibiotics were detected using surface-assisted laser desorption/ionization mass spectrometry (SALDI/MS) with colloidal silver as the matrix. Under optimum conditions, the limits of detection (LODs) at a signal-to-noise ratio of 3 were 2, 3, 3, and 2 nM for erythromycin (ERY), spiramycin (SPI), tilmicosin (TILM), and tylosin (TYL), respectively. This developed method was successfully applied to the determination of macrolide antibiotics in human urine samples.
Sklerov, J H; Kalasinsky, K S; Ehorn, C A
1999-10-01
A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were < 6% and < 13%, respectively. This procedure has been applied to quality-control specimens and LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.
NASA Astrophysics Data System (ADS)
Yu, Yajun; Sanchez, Nancy P.; Yi, Fan; Zheng, Chuantao; Ye, Weilin; Wu, Hongpeng; Griffin, Robert J.; Tittel, Frank K.
2017-05-01
A sensor system capable of simultaneous measurements of NO and NO2 was developed using a wavelength modulation-division multiplexing (WMDM) scheme and multi-pass absorption spectroscopy. A continuous wave (CW), distributed-feedback (DFB) quantum cascade laser (QCL) and a CW external-cavity (EC) QCL were employed for targeting a NO absorption doublet at 1900.075 cm-1 and a NO2 absorption line at 1630.33 cm-1, respectively. Simultaneous detection was realized by modulating both QCLs independently at different frequencies and demodulating the detector signals with LabView-programmed lock-in amplifiers. The sensor operated at a reduced pressure of 40 Torr and a data sampling rate of 1 Hz. An Allan-Werle deviation analysis indicated that the minimum detection limits of NO and NO2 can reach sub-ppbv concentration levels with averaging times of 100 and 200 s, respectively.
Sun, Wanqi; Liang, Miao; Li, Zhen; Shu, Jinian; Yang, Bo; Xu, Ce; Zou, Yao
2016-08-15
On-spot monitoring of threat agents needs high sensitive instrument. In this study, a low-pressure photoionization mass spectrometer (LPPI-MS) was employed to detect trace amounts of vapor-phase explosives and chemical warfare agent mimetics under ambient conditions. Under 10-s detection time, the limits of detection of 2,4-dinitrotoluene, nitrotoluene, nitrobenzene, and dimethyl methyl phosphonate were 30, 0.5, 4, and 1 parts per trillion by volume, respectively. As compared to those obtained previously with PI mass spectrometric techniques, an improvement of 3-4 orders of magnitude was achieved. This study indicates that LPPI-MS will open new opportunities for the sensitive detection of explosives and chemical warfare agents. Copyright © 2016 Elsevier B.V. All rights reserved.
Detection of small molecules with a flow immunosensor
NASA Technical Reports Server (NTRS)
Kusterbeck, Anne W.; Ligler, Frances S.
1991-01-01
We describe the development of an easy-to-use sensor with widespread applications for detecting small molecules. The flow immunosensor can analyze discrete samples in under one minute or continuously monitor a flowing stream for the presence of specific analytes. This detection system is extremely specific, and achieves a level of sensitivity which meets or exceeds the detection limits reported for rival assays. Because the system is also compact, transportable, and automated, it has the potential to impact diverse areas. For example, the flow immunosensor has successfully detected drugs of abuse and explosives, and may well address many of the needs of the environmental community with respect to continuous monitoring for pollutants. Efforts are underway to engineer a portable device in the field.
NASA Astrophysics Data System (ADS)
Gallenne, A.; Mérand, A.; Kervella, P.; Monnier, J. D.; Schaefer, G. H.; Baron, F.; Breitfelder, J.; Le Bouquin, J. B.; Roettenbacher, R. M.; Gieren, W.; Pietrzyński, G.; McAlister, H.; ten Brummelaar, T.; Sturmann, J.; Sturmann, L.; Turner, N.; Ridgway, S.; Kraus, S.
2015-07-01
Context. Long-baseline interferometry is an important technique to spatially resolve binary or multiple systems in close orbits. By combining several telescopes together and spectrally dispersing the light, it is possible to detect faint components around bright stars in a few hours of observations. Aims: We provide a rigorous and detailed method to search for high-contrast companions around stars, determine the detection level, and estimate the dynamic range from interferometric observations. Methods: We developed the code CANDID (Companion Analysis and Non-Detection in Interferometric Data), a set of Python tools that allows us to search systematically for point-source, high-contrast companions and estimate the detection limit using all interferometric observables, i.e., the squared visibilities, closure phases and bispectrum amplitudes. The search procedure is made on a N × N grid of fit, whose minimum needed resolution is estimated a posteriori. It includes a tool to estimate the detection level of the companion in the number of sigmas. The code CANDID also incorporates a robust method to set a 3σ detection limit on the flux ratio, which is based on an analytical injection of a fake companion at each point in the grid. Our injection method also allows us to analytically remove a detected component to 1) search for a second companion; and 2) set an unbiased detection limit. Results: We used CANDID to search for the companions around the binary Cepheids V1334 Cyg, AX Cir, RT Aur, AW Per, SU Cas, and T Vul. First, we showed that our previous discoveries of the components orbiting V1334 Cyg and AX Cir were detected at >25σ and >13σ, respectively. The astrometric positions and flux ratios provided by CANDID for these two stars are in good agreement with our previously published values. The companion around AW Per is detected at more than 15σ with a flux ratio of f = 1.22 ± 0.30%, and it is located at ρ = 32.16 ± 0.29 mas and PA = 67.1 ± 0.3°. We made a possible detection of the companion orbiting RT Aur with f = 0.22 ± 0.11%, and at ρ = 2.10 ± 0.23 mas and PA = -136 ± 6°. It was detected at 3.8σ using the closure phases only, and so more observations are needed to confirm the dectection. No companions were detected around SU Cas and T Vul. We also set the detection limit for possible undetected companions around these stars. We found that there is no companion with a spectral type earlier than B7V, A5V, F0V, B9V, A0V, and B9V orbiting the Cepheids V1334 Cyg, AX Cir, RT Aur, AW Per, SU Cas, and T Vul, respectively. This work also demonstrates the capabilities of the MIRC and PIONIER instruments, which can reach a dynamic range of 1:200, depending on the angular distance of the companion and the (u,v) plane coverage. In the future, we plan to work on improving the sensitivity limits for realistic data through better handling of the correlations. The current version of the code is available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/579/A68
Chan, W; Gerhardt, G C; Salisbury, C D
1994-01-01
A method for the simultaneous determination of tylosin and tilmicosin residues in animal tissues is reported. Solid-phase extraction columns are used to isolate the drugs from tissue extracts. Determination is accomplished by reversed-phase liquid chromatography with UV detection at 287 nm. Mean recoveries from spiked tissues were 79.9% (coefficient of variation [CV], 8.1%) for tylosin and 92.6% (CV, 8.7%) for tilmicosin. Detection limits for tylosin and tilmicosin were 0.020 and 0.010 ppm, respectively.
De Clercq, Nathalie; Julie, Vanden Bussche; Croubels, Siska; Delahaut, Philippe; Vanhaecke, Lynn
2013-08-02
Due to their growth-promoting effects, the use of synthetic glucocorticoids is strictly regulated in the European Union (Council Directive 2003/74/EC). In the frame of the national control plans, which should ensure the absence of residues in food products of animal origin, in recent years, a higher frequency of prednisolone positive bovine urines has been observed. This has raised questions with respect to the stability of natural corticoids in the respective urine samples and their potential to be transformed into synthetic analogs. In this study, a ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology was developed to examine the stability of glucocorticoids in bovine urine under various storage conditions (up to 20 weeks) and to define suitable conditions for sample handling and storage, using an Orbitrap Exactive™. To this end, an extraction procedure was optimized using a Plackett-Burman experimental design to determine the key conditions for optimal extraction of glucocorticoids from urine. Next, the analytical method was successfully validated according to the guidelines of CD 2002/657/EC. Decision limits and detection capabilities for prednisolone, prednisone and methylprednisolone ranged, respectively, from 0.1 to 0.5μgL(-1) and from 0.3 to 0.8μgL(-1). For the natural glucocorticoids limits of detection and limits of quantification for dihydrocortisone, cortisol and cortisone ranged, respectively, from 0.1 to 0.2μgL(-1) and from 0.3 to 0.8μgL(-1). The stability study demonstrated that filter-sterilization of urine, storage at -80°C, and acidic conditions (pH 3) were optimal for preservation of glucocorticoids in urine and able to significantly limit degradation up to 20 weeks. Copyright © 2013 Elsevier B.V. All rights reserved.
Finite-size analysis of the detectability limit of the stochastic block model
NASA Astrophysics Data System (ADS)
Young, Jean-Gabriel; Desrosiers, Patrick; Hébert-Dufresne, Laurent; Laurence, Edward; Dubé, Louis J.
2017-06-01
It has been shown in recent years that the stochastic block model is sometimes undetectable in the sparse limit, i.e., that no algorithm can identify a partition correlated with the partition used to generate an instance, if the instance is sparse enough and infinitely large. In this contribution, we treat the finite case explicitly, using arguments drawn from information theory and statistics. We give a necessary condition for finite-size detectability in the general SBM. We then distinguish the concept of average detectability from the concept of instance-by-instance detectability and give explicit formulas for both definitions. Using these formulas, we prove that there exist large equivalence classes of parameters, where widely different network ensembles are equally detectable with respect to our definitions of detectability. In an extensive case study, we investigate the finite-size detectability of a simplified variant of the SBM, which encompasses a number of important models as special cases. These models include the symmetric SBM, the planted coloring model, and more exotic SBMs not previously studied. We conclude with three appendices, where we study the interplay of noise and detectability, establish a connection between our information-theoretic approach and random matrix theory, and provide proofs of some of the more technical results.
Resolution Limits of Nanoimprinted Patterns by Fluorescence Microscopy
NASA Astrophysics Data System (ADS)
Kubo, Shoichi; Tomioka, Tatsuya; Nakagawa, Masaru
2013-06-01
The authors investigated optical resolution limits to identify minimum distances between convex lines of fluorescent dye-doped nanoimprinted resist patterns by fluorescence microscopy. Fluorescent ultraviolet (UV)-curable resin and thermoplastic resin films were transformed into line-and-space patterns by UV nanoimprinting and thermal nanoimprinting, respectively. Fluorescence immersion observation needed an immersion medium immiscible to the resist films, and an ionic liquid of triisobutyl methylphosphonium tosylate was appropriate for soluble thermoplastic polystyrene patterns. Observation with various numerical aperture (NA) values and two detection wavelength ranges showed that the resolution limits were smaller than the values estimated by the Sparrow criterion. The space width to identify line patterns became narrower as the line width increased. The space width of 100 nm was demonstrated to be sufficient to resolve 300-nm-wide lines in the detection wavelength range of 575-625 nm using an objective lens of NA= 1.40.
Solid phase microextraction applied to the analysis of organophosphorus insecticides in fruits.
Fytianos, K; Raikos, N; Theodoridis, G; Velinova, Z; Tsoukali, H
2006-12-01
Trace amounts of organophosphorus pesticides (OPs) were determined in various fruits by headspace solid phase microextraction (HS-SPME) and gas chromatography-nitrogen phosphorous detection (GC-NPD). Sampling from the headspace enhanced method selectivity, whereas at the same time improved fiber life time and method sensitivity. Diazinon, parathion, methyl parathion, malathion and fenithrothion were determined in various fruits: more than 150 samples of 21 types of fruits were studied. SPME-GC-NPD provided a useful and very efficient analytical tool: method linearity ranged from 1.2 to 700 ng/ml. Limits of detection (LODs) and quantitation (LOQs) ranged from 0.03 to 3 ng/ml and 0.12 to 10 ng/ml respectively, values well below the residue limits set by the EU. Less than 2% of the samples were found positive containing amounts higher than the EU limits. The effect of fruit peeling and washing was also investigated.
Randomized Prediction Games for Adversarial Machine Learning.
Rota Bulo, Samuel; Biggio, Battista; Pillai, Ignazio; Pelillo, Marcello; Roli, Fabio
In spam and malware detection, attackers exploit randomization to obfuscate malicious data and increase their chances of evading detection at test time, e.g., malware code is typically obfuscated using random strings or byte sequences to hide known exploits. Interestingly, randomization has also been proposed to improve security of learning algorithms against evasion attacks, as it results in hiding information about the classifier to the attacker. Recent work has proposed game-theoretical formulations to learn secure classifiers, by simulating different evasion attacks and modifying the classification function accordingly. However, both the classification function and the simulated data manipulations have been modeled in a deterministic manner, without accounting for any form of randomization. In this paper, we overcome this limitation by proposing a randomized prediction game, namely, a noncooperative game-theoretic formulation in which the classifier and the attacker make randomized strategy selections according to some probability distribution defined over the respective strategy set. We show that our approach allows one to improve the tradeoff between attack detection and false alarms with respect to the state-of-the-art secure classifiers, even against attacks that are different from those hypothesized during design, on application examples including handwritten digit recognition, spam, and malware detection.In spam and malware detection, attackers exploit randomization to obfuscate malicious data and increase their chances of evading detection at test time, e.g., malware code is typically obfuscated using random strings or byte sequences to hide known exploits. Interestingly, randomization has also been proposed to improve security of learning algorithms against evasion attacks, as it results in hiding information about the classifier to the attacker. Recent work has proposed game-theoretical formulations to learn secure classifiers, by simulating different evasion attacks and modifying the classification function accordingly. However, both the classification function and the simulated data manipulations have been modeled in a deterministic manner, without accounting for any form of randomization. In this paper, we overcome this limitation by proposing a randomized prediction game, namely, a noncooperative game-theoretic formulation in which the classifier and the attacker make randomized strategy selections according to some probability distribution defined over the respective strategy set. We show that our approach allows one to improve the tradeoff between attack detection and false alarms with respect to the state-of-the-art secure classifiers, even against attacks that are different from those hypothesized during design, on application examples including handwritten digit recognition, spam, and malware detection.
Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger
2013-09-13
A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.
Determination of benzocaine in rainbow trout plasma
Bernardy, Jeffery A.; Coleman, K.S.; Stehly, G.R.; Gingerich, William H.
1996-01-01
A liquid chromatographic method is described for analysis of benzocaine (BZ), a proposed fish anesthetic, in rainbow trout plasma, Mean recoveries of BZ from plasma samples fortified at 44-10 100 ng/mL were 96-100%. The method detection limit is 10 ng/mL, and the limit of quantitation is 37 ng/mL. Acetylation of BZ occurs in whole blood after storage at room temperature (i.e., 21 degrees C) for 10 min. However, no acetylation of BZ was detected in plasma samples held at room temperature for 4 h, Mean method precision for plasma samples with incurred BZ residue is similar to that for fortified samples in the same concentration range (relative standard deviations of 0.9 and 1.2%, respectively).
de Macedo, A. N.; Vicente, G. H. L.; Nogueira, A. R. A.
2010-01-01
A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography – mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L−1 and 0.02 mg kg−1, respectively. PMID:21165598
Atom-Based Sensing of Weak Radio Frequency Electric Fields Using Homodyne Readout
Kumar, Santosh; Fan, Haoquan; Kübler, Harald; Sheng, Jiteng; Shaffer, James P.
2017-01-01
We utilize a homodyne detection technique to achieve a new sensitivity limit for atom-based, absolute radio-frequency electric field sensing of 5 μV cm−1 Hz−1/2. A Mach-Zehnder interferometer is used for the homodyne detection. With the increased sensitivity, we investigate the dominant dephasing mechanisms that affect the performance of the sensor. In particular, we present data on power broadening, collisional broadening and transit time broadening. Our results are compared to density matrix calculations. We show that photon shot noise in the signal readout is currently a limiting factor. We suggest that new approaches with superior readout with respect to photon shot noise are needed to increase the sensitivity further. PMID:28218308
NASA Astrophysics Data System (ADS)
Byram, Chandu; Moram, Sree Sathya Bharathi; Shaik, Abdul Kalam; Soma, Venugopal Rao
2017-10-01
We demonstrate the detection of picric acid (PA) and ammonium nitrate (AN) at μM concentrations by utilizing gold (Au) nanostructures (NSs) as surface enhanced Raman scattering (SERS) substrates fabricated using the technique of ultrafast laser ablation in liquids. Au NPs and NSs were also utilized for detecting Rhodamine 6G (Rh6G) and methylene blue (MB). Detection of all the molecules using the same substrates (NPs and NSs) demonstrated their versatility. Detection limits of 10-5, 10-6, 10-7, 10-8 M were achieved for AN, PA, Rh6G and MB, respectively. Reproducibility of the SERS intensity using NSs and NPs as substrates demonstrate their efficacy.
Szulczyński, Bartosz; Wasilewski, Tomasz; Wojnowski, Wojciech; Majchrzak, Tomasz; Dymerski, Tomasz; Namieśnik, Jacek; Gębicki, Jacek
2017-01-01
This review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents commercially available sensors utilized in the electronic noses and characterized by the limit of quantification below 1 ppm v/v, which is close to the odour threshold of some odorants. Additionally, information about bioelectronic noses being a possible alternative to electronic noses and their principle of operation and application potential in the field of air evaluation with respect to detection of the odorants characterized by unpleasant odour was provided. PMID:29156597
NASA Astrophysics Data System (ADS)
Xu, B. Y.; Ye, Y.; Liao, L. C.
2016-07-01
A new method was developed to determine the methamphetamine and morphine concentrations in urine and saliva based on excitation-emission matrix fluorescence coupled to a second-order calibration algorithm. In the case of single-drug abuse, the results showed that the average recoveries of methamphetamine and morphine were 95.3 and 96.7% in urine samples, respectively, and 98.1 and 106.2% in saliva samples, respectively. The relative errors were all below 5%. The simultaneous determination of methamphetamine and morphine in urine using two second-order algorithms was also investigated. Satisfactory results were obtained with a self-weighted alternating trilinear decomposition algorithm. The root-mean-square errors of the predictions were 0.540 and 0.0382 μg/mL for methamphetamine and morphine, respectively. The limits of detection of the proposed methods were very low and sufficient for studying methamphetamine and morphine in urine.
Szulczyński, Bartosz; Wasilewski, Tomasz; Wojnowski, Wojciech; Majchrzak, Tomasz; Dymerski, Tomasz; Namieśnik, Jacek; Gębicki, Jacek
2017-11-19
This review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents commercially available sensors utilized in the electronic noses and characterized by the limit of quantification below 1 ppm v / v , which is close to the odour threshold of some odorants. Additionally, information about bioelectronic noses being a possible alternative to electronic noses and their principle of operation and application potential in the field of air evaluation with respect to detection of the odorants characterized by unpleasant odour was provided.
Vertzoni, M V; Reppas, C; Archontaki, H A
2006-07-24
An isocratic high-performance liquid chromatographic method with detection at 240 nm was developed, optimized and validated for the determination of ketoconazole in canine plasma. 9-Acetylanthracene was used as internal standard. A Hypersil BDS RP-C18 column (250 mm x 4.6 mm, 5 microm particle size), was equilibrated with a mobile phase composed of methanol, water and diethylamine 74:26:0.1 (v/v/v). Its flow rate was 1 ml/min. The elution time for ketoconazole and 9-acetylanthracene was approximately 9 and 8 min, respectively. Calibration curves of ketoconazole in plasma were linear in the concentration range of 0.015-10 microg/ml. Limits of detection and quantification in plasma were 5 and 15 ng/ml, respectively. Recovery was greater than 95%. Intra- and inter-day relative standard deviation for ketoconazole in plasma was less than 3.1 and 4.7%, respectively. This method was applied to the determination of ketoconazole plasma levels after administration of a commercially available tablet to dogs.
Feature-fused SSD: fast detection for small objects
NASA Astrophysics Data System (ADS)
Cao, Guimei; Xie, Xuemei; Yang, Wenzhe; Liao, Quan; Shi, Guangming; Wu, Jinjian
2018-04-01
Small objects detection is a challenging task in computer vision due to its limited resolution and information. In order to solve this problem, the majority of existing methods sacrifice speed for improvement in accuracy. In this paper, we aim to detect small objects at a fast speed, using the best object detector Single Shot Multibox Detector (SSD) with respect to accuracy-vs-speed trade-off as base architecture. We propose a multi-level feature fusion method for introducing contextual information in SSD, in order to improve the accuracy for small objects. In detailed fusion operation, we design two feature fusion modules, concatenation module and element-sum module, different in the way of adding contextual information. Experimental results show that these two fusion modules obtain higher mAP on PASCAL VOC2007 than baseline SSD by 1.6 and 1.7 points respectively, especially with 2-3 points improvement on some small objects categories. The testing speed of them is 43 and 40 FPS respectively, superior to the state of the art Deconvolutional single shot detector (DSSD) by 29.4 and 26.4 FPS.
Andrade, Mariane A; Lanças, Fernando M
2017-04-14
Ochratoxin A (OTA), a widely studied mycotoxin, can be found in a variety of food matrices. As its concentration in food is generally low (in the order of μg kg -1 ), sample preparation techniques are necessary for the analyte purification and pre-concentration in order to achieve the required low detection limits. The separation and detection methods used for OTA analysis should also offer proper sensitivity in order to allow the adequate quantification of the analyte. This manuscript addresses the development of a methodology aiming the analysis of OTA in wine samples by packed in-tube SPME in flow through extraction mode coupled to HPLC-MS/MS. The in-tube SPME set up utilized a PEEK tube packed with C18 particles as the extraction column. The method was optimized by a central composite design 2 2 +3 extra central points, having as factors the percentage of ACN and time in the sample load step. The functionalities of the method were attested and its analytical conditions, enhanced by using 22% of ACN and 6min in the sample load step. Validation of the method was also accomplished prior to analyses of both dry red wine and dry white wine samples. The method demonstrated proper sensitivity, with detection and quantification limits equal to 0.02 and 0.05μgL -1 , respectively. Linearity and precision exhibited a 0.996 correlation coefficient and RSD under 6%, respectively. The method proved to be accurate at medium and higher concentration levels with a maximum recovery of 73% at higher concentration levels. OTA was not detected in either dry red and dry white wine samples evaluated in this work. If present, it would be at concentrations lower than the detection and quantification limits established for the proposed method, and considered not a potential danger to human health according to our present knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.
Senachai, Pachara; Chomvarin, Chariya; Namwat, Wises; Wongboot, Warawan; Wongwajana, Suwin; Tangkanakul, Waraluk
2013-03-01
A tetraplex PCR method was developed for simultaneous detection of Vibrio cholerae, V. parahaemolyticus, V. vulnificus and V. mimicus in cockle samples in comparison with conventional culture method. Specific primers targeting ompW of V. cholerae, tl of V. parahaemolyticus, hsp60 of V. vulnificus and sodB of V. mimicus were employed in the same PCR. Detection limit of the tetraplex PCR assay was 104 cfu/ml (400 cfu/PCR reaction) for pure cultures of all four species of Vibrio. In Vibrio spiked cockle samples, the limit of detection after 6 hours enrichment in alkaline peptone water was 1 cfu/10 g of cockle tissue for three Vibrio spp, except for V. mimicus that was 102 cfu/10 g of cockle tissue. When the tetraplex PCR and culture methods were applied to 100 cockle samples, V. parahaemolyticus, V. vulnificus, V. cholerae and V. mimicus were detected in 100, 98, 80 and 9% of the samples by tetraplex PCR and in 76, 42, 0 and 0% by the culture method, respectively. This developed tetraplex PCR method should be suitable for simultaneous and rapid detection of Vibrio species in food samples and for food safety assessment.
A fully automated microfluidic-based electrochemical sensor for real-time bacteria detection.
Altintas, Zeynep; Akgun, Mete; Kokturk, Guzin; Uludag, Yildiz
2018-02-15
A fully automated microfluidic-based electrochemical biosensor was designed and manufactured for pathogen detection. The quantification of Escherichia coli was investigated with standard and nanomaterial amplified immunoassays in the concentration ranges of 0.99 × 10 4 3.98 × 10 9 cfu mL -1 and 103.97 × 10 7 cfu mL -1 which resulted in detection limits of 1.99 × 10 4 cfu mL -1 and 50 cfu mL -1 , respectively. The developed methodology was then applied for E. coli quantification in water samples using nanomaterial modified assay. Same detection limit for E. coli was achieved for real sample analysis with a little decrease on the sensor signal. Cross-reactivity studies were conducted by testing Shigella, Salmonella spp., Salmonella typhimurium and Staphylococcus aureus on E. coli specific antibody surface that confirmed the high specificity of the developed immunoassays. The sensor surface could be regenerated multiple times which significantly reduces the cost of the system. Our custom-designed biosensor is capable of detecting bacteria with high sensitivity and specificity, and can serve as a promising tool for pathogen detection. Copyright © 2017 Elsevier B.V. All rights reserved.
Chow, Cheuk-Fai; Ho, Pui-Yu; Gong, Cheng-Bin
2014-09-07
A tetranuclear bimetallic complex, [Ru(II)((t)Bubpy)(CN)4]2-[Fe(III)(H2O)3Cl]2·8H2O (1) has been synthesized and characterized. It was found to be a multifunctional device that can detect, signal amplify, and degrade an organic pollutant, oxalate. Results of the chemosensing studies of 1 toward common anions show that only oxalate selectively induces naked-eye colorimetric and luminometric responses with method detection limits down to 78.7 and 5.5 ppm, respectively from 1. Meanwhile, results of the photo-degradation studies of 1 toward oxalate show that the dissolved organic carbon content of oxalate decreased and reached complete mineralization into CO2 within 6 hours. Complex 1 was also found as the catalyst that amplified the detection signal toward oxalate. Through the photoassisted Fenton reaction by 1, methyl orange, an additional coloring agent, could be degraded so that the visual detection limit of 1 toward oxalate was magnified 50 times from 100 to 2 ppm. The detection, degradation, mineralization and signal amplification were found applicable in real water bodies such as river, pond and underground water with excellent recoveries and relative standard deviation.
Fang, Xin-Yu; Li, Wen-Bo; Zhang, Chao-Fan; Huang, Zi-da; Zeng, Hui-Yi; Dong, Zheng; Zhang, Wen-Ming
2018-02-01
To explore the diagnostic efficiency of DNA-based and RNA-based quantitative polymerase chain reaction (qPCR) analyses for periprosthetic joint infection (PJI). To determine the detection limit of DNA-based and RNA-based qPCR in vitro, Staphylococcus aureus and Escherichia coli strains were added to sterile synovial fluid obtained from a patient with knee osteoarthritis. Serial dilutions of samples were analyzed by DNA-based and RNA-based qPCR. Clinically, patients who were suspected of having PJI and eventually underwent revision arthroplasty in our hospital from July 2014 to December 2016 were screened. Preoperative puncture or intraoperative collection was performed on patients who met the inclusion and exclusion criteria to obtain synovial fluid. DNA-based and RNA-based PCR analyses and culture were performed on each synovial fluid sample. The patients' demographic characteristics, medical history, and laboratory test results were recorded. The diagnostic efficiency of both PCR assays was compared with culture methods. The in vitro analysis demonstrated that DNA-based qPCR assay was highly sensitive, with the detection limit being 1200 colony forming units (CFU)/mL of S. aureus and 3200 CFU/mL of E. coli. Meanwhile, The RNA-based qPCR assay could detect 2300 CFU/mL of S. aureus and 11 000 CFU/mL of E. coli. Clinically, the sensitivity, specificity, and accuracy were 65.7%, 100%, and 81.6%, respectively, for the culture method; 81.5%, 84.8%, and 83.1%, respectively, for DNA-based qPCR; and 73.6%, 100%, and 85.9%, respectively, for RNA-based qPCR. DNA-based qPCR could detect suspected PJI with high sensitivity after antibiotic therapy. RNA-based qPCR could reduce the false positive rates of DNA-based assays. qPCR-based methods could improve the efficiency of PJI diagnosis. © 2018 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Xue, Huyin; Xing, Yue; Yin, Yongmei; Zhang, Taichang; Zhang, Bo; Zhang, Yu; Song, Pei; Tian, Xi; Xu, Yinghui; Wang, Peng; Meng, Meng; Xi, Rimo
2012-01-01
This paper reports the preparation of polyclonal antibodies against a synthetic azo dye, Orange II, and the development of an indirect ELISA to detect Orange II in foods. The sulfonic group of Orange II was modified and linked with carrier protein to synthesise an artificial antigen. Based on the checkerboard titration, the method showed excellent sensitivity (IC₅₀ = 0.61 ng g⁻¹) to Orange II in the linear range of 0.05-10 ng g⁻¹. The antibody had little cross-reactivity with Chromotrope FB, Gardenia Yellow, Ponceau 4R, Sunset Yellow and Sudan dyes. The ELISA had limits of detection (LOD) of 0.22, 0.97 and 0.74 ng g⁻¹ in chilli powder, chilli oil and braised pork, respectively. The limits of quantification (LOQ) of the assay were 0.91 ng g⁻¹ in chilli powder, 1.48 ng g⁻¹ in chilli oil and 1.10 ng g⁻¹ in braised pork. For food products fortified with 1-10 ng g⁻¹ Orange II, the inter- and intra-assay variations were all less than 24.0% and 18.0%, respectively. Therefore, the proposed test could be used as a rapid screening method for Orange II detection in food samples.
Weon, Jin Bae; Yang, Hye Jin; Lee, Bohyoung; Ma, Jin Yeul; Ma, Choong Je
2015-01-01
Background: Samsoeum was traditionally used for treatment of a respiratory disease. Objective: The simultaneous determination of eight major compounds, ginsenoside Rg3, caffeic acid, puerarin, costunolide, hesperidin, naringin, glycyrrhizin, and 6-gingerol in the Samsoeum using a high-performance liquid chromatography (HPLC) coupled with diode array detection (DAD) and an electrospray ionization mass spectrometer was developed for an accurate and reliable quality assessment. Materials and Methods: Eight compounds were qualitative identified based on their mass spectra and by comparing with standard compounds and quantitative analyzed by HPLC-DAD. Separation of eight compounds was carried out on a LUNA C18 column (S-5 μm, 4.6 mm i.d. ×250 mm) with gradient elution composed of acetonitrile and 0.1% trifluoroacetic acid. Results: The data showed good linearity (R2 > 0.9996). The limits of detection and the limits of quantification were <0.53 μg and 1.62 μg, respectively. Inter- and Intra-day precisions (expressed as relative standard deviation values) were within 1.94% and 1.91%, respectively. The recovery of the method was in the range of 94.24–107.90%. Conclusion: The established method is effective and could be applied to quality control of Samsoeum. PMID:25829771
Chaparro, L L; Ferrer, L; Cerdà, V; Leal, L O
2012-09-01
A multisyringe flow-injection approach has been coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS) with UV photo-oxidation for dimethylarsinic (DMA), inorganic As and total As determination, depending on the pre-treatment given to the sample (extraction or digestion). The implementation of a UV lamp allows on-line photo-oxidation of DMA and the following arsenic detection, whereas a bypass leads the flow directly to the HG-AFS system, performing inorganic arsenic determination. DMA concentration is calculated by the difference of total inorganic arsenic and measurement of the photo-oxidation step. The detection limits for DMA and inorganic arsenic were 0.09 and 0.47 μg L(-1), respectively. The repeatability values accomplished were of 2.4 and 1.8%, whereas the injection frequencies were 24 and 28 injections per hour for DMA and inorganic arsenic, respectively. This method was validated by means of a solid reference material BCR-627 (muscle of tuna) with good agreement with the certified values. Satisfactory results for DMA and inorganic arsenic determination were obtained in several water matrices. The proposed method offers several advantages, such as increasing the sampling frequency, low detection limits and decreasing reagents and sample consumption, which leads to lower waste generation.
Lee, Jihyeon; Park, Sehwan; Cho, Soo Gyeong; Goh, Eun Mee; Lee, Sungman; Koh, Sung-Suk; Kim, Jeongkwon
2014-03-01
Corona discharge ionization combined with ion mobility spectrometry-mass spectrometry (IMS-MS) was utilized to investigate five common explosives: cyclonite (RDX), trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), cyclotetramethylenetetranitramine (HMX), and 2,4-dinitrotoluene (DNT). The MS scan and the selected ion IMS analyses confirmed the identities of the existing ion species and their drift times. The ions observed were RDX·NO3(-), TNT(-), PETN·NO3(-), HMX·NO3(-), and DNT(-), with average drift times of 6.93 ms, 10.20 ms, 9.15 ms, 12.24 ms, 11.30 ms, and 8.89 ms, respectively. The reduced ion mobility values, determined from a standard curve calculated by linear regression of (normalized drift times)(-1) versus literature K0 values, were 2.09, 1.38, 1.55, 1.15, 1.25, and 1.60 cm(2) V(-1) s(-1), respectively. The detection limits were found to be 0.1 ng for RDX, 10 ng for TNT, 0.5 ng for PETN, 5.0 ng for HMX, and 10 ng for DNT. Simplified chromatograms were observed when nitrogen, as opposed to air, was used as the drift gas, but the detection limits were approximately 10 times worse (i.e., less sensitivity of detection). © 2013 Elsevier B.V. All rights reserved.
Gómez-Ariza, José Luis; Lorenzo, Fernando; García-Barrera, Tamara
2005-05-01
Mercury and arsenic are two elements of undoubted importance owing to their toxic character. Although speciation of these elements has been developed separately, in this work for the first time the speciation of As and Hg using two atomic fluorescence detectors in a sequential ensemble is presented. A coupling based on the combination of high-performance liquid chromatography (where mercury and arsenic species are separated) and two atomic fluorescence detectors in series, with several online treatments, including photooxidation (UV) and hydride generation, has allowed the determination of mercury and arsenic compounds simultaneously. The detection limits for this device were 16, 3, 17, 12 and 8 ng mL(-1) for As(III), monomethylarsinic acid, As(V), Hg2+ and methylmercury, respectively. This coupling was compared with an analogous one based on inductively coupled plasma-mass spectrometry (ICP-MS) detection, with detection limits of 0.7, 0.5, 0.8, 0.9 and 1.1 ng mL(-1), respectively. Multispeciation based on ICP-MS exhibits better sensitivity than the coupling based on tandem atomic fluorescence, but this second device is a very robust system and exhibits obvious advantages related to the low cost of acquisition and maintenance, as well as easy handling, which makes it a suitable system for routine laboratories.
NASA Astrophysics Data System (ADS)
Tang, Xu; Han, Juan; Wang, Yun; Ni, Liang; Bao, Xu; Wang, Lei; Zhang, Wenli
2017-02-01
Chemosensors play important parts in the selective recognition of ions, which is widely applied in various fields of environment, industry and biological sciences. In this work, a chemosensor for multi-metal ions based on rhodamine B derivative was synthesized, which could selectively recognize various metal ions in different solvent system. The addition of Cu2 + caused the color change from colorless to pink in EtOH/H2O (v/v = 1:1) solvent system, which could be quickly identified by the naked eyes with a detection limit of 8.27 × 10- 8 M. In ethanol solution system, the addition of Fe3 + and Zn2 + caused different fluorescence changes with the detection limit of 2.12 × 10- 7 M and 6.64 × 10- 7 M respectively. The binding ratios are 1:1 (1-Cu2 +), 2:1 (1-Fe3 +) and 1:1 (1-Zn2 +), respectively. Meanwhile, the probe 1 was used to detect the trace metal ions in real water samples. Besides, the probe 1 showed sensitive fluorescence signals for Fe3 + in biological cells. The experimental results further verify the application value of the sensor.
DNA Microarray Detection of 18 Important Human Blood Protozoan Species
Chen, Jun-Hu; Feng, Xin-Yu; Chen, Shao-Hong; Cai, Yu-Chun; Lu, Yan; Zhou, Xiao-Nong; Chen, Jia-Xu; Hu, Wei
2016-01-01
Background Accurate detection of blood protozoa from clinical samples is important for diagnosis, treatment and control of related diseases. In this preliminary study, a novel DNA microarray system was assessed for the detection of Plasmodium, Leishmania, Trypanosoma, Toxoplasma gondii and Babesia in humans, animals, and vectors, in comparison with microscopy and PCR data. Developing a rapid, simple, and convenient detection method for protozoan detection is an urgent need. Methodology/Principal Findings The microarray assay simultaneously identified 18 species of common blood protozoa based on the differences in respective target genes. A total of 20 specific primer pairs and 107 microarray probes were selected according to conserved regions which were designed to identify 18 species in 5 blood protozoan genera. The positive detection rate of the microarray assay was 91.78% (402/438). Sensitivity and specificity for blood protozoan detection ranged from 82.4% (95%CI: 65.9% ~ 98.8%) to 100.0% and 95.1% (95%CI: 93.2% ~ 97.0%) to 100.0%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) ranged from 20.0% (95%CI: 2.5% ~ 37.5%) to 100.0% and 96.8% (95%CI: 95.0% ~ 98.6%) to 100.0%, respectively. Youden index varied from 0.82 to 0.98. The detection limit of the DNA microarrays ranged from 200 to 500 copies/reaction, similar to PCR findings. The concordance rate between microarray data and DNA sequencing results was 100%. Conclusions/Significance Overall, the newly developed microarray platform provides a convenient, highly accurate, and reliable clinical assay for the determination of blood protozoan species. PMID:27911895
NASA Astrophysics Data System (ADS)
Gondal, M. A.; Dastageer, M. A.; Al-Adel, F. F.; Naqvi, A. A.; Habibullah, Y. B.
2015-12-01
A sensitive laser induced breakdown spectroscopic system was developed and optimized for using it as a sensor for the detection of trace levels of lead and chromium present in the cosmetic eyeliner (kohl) of different price ranges (brands) available in the local market. Kohl is widely used in developing countries for babies as well adults for beautification as well eyes protection. The atomic transition lines at 405.7 nm and 425.4 nm were used as the marker lines for the detection of lead and chromium respectively. The detection system was optimized by finding the appropriate gate delay between the laser excitation and the data acquisition system and also by achieving optically thin plasma near the target by establishing the local thermodynamic equilibrium condition. The detection system was calibrated for these two hazardous elements and the kohl samples under investigation showed 8-15 ppm by mass of lead and 4-9 ppm by mass of Chromium, which are higher than the safe permissible levels of these elements. The limits of detection of the LIBS system for lead and chromium were found to be 1 and 2 ppm respectively.
Application of the Mars Organic Analyzer to nucleobase and amine biomarker detection.
Skelley, Alison M; Cleaves, H James; Jayarajah, Christine N; Bada, Jeffrey L; Mathies, Richard A
2006-12-01
The Mars Organic Analyzer (MOA), a portable microfabricated capillary electrophoresis instrument being developed for planetary exploration, is used to analyze a wide variety of fluorescamine-labeled amine-containing biomarker compounds, including amino acids, mono and diaminoalkanes, amino sugars, nucleobases, and nucleobase degradation products. The nucleobases cytosine and adenine, which contain an exocyclic primary amine, were effectively labeled, separated, and detected at concentrations <500 nM. To test the general applicability of the MOA for biomarker detection, amino acids and mono- and diamines were extracted from bacterial cells using both hydrolysis and sublimation followed by analysis. The extrapolated limit of detection provided by the valine biomarker was approximately 4 x 10(3) cells per sample. Products of an NH(4)CN polymerization that simulate a prebiotic synthesis were also successfully isolated via sublimation and analyzed. Adenine and alanine/serine were detected with no additional sample cleanup at 120 +/- 13 microM and 4.1 +/- 1 microM, respectively, corresponding to a reaction yield of 0.04% and 0.0003%, respectively. This study demonstrates that the MOA provides sensitive detection and analysis of low levels of a wide variety of amine-containing organic compounds from both biological and abiotic sources.
NASA Astrophysics Data System (ADS)
Pedarnig, J. D.; Haslinger, M. J.; Bodea, M. A.; Huber, N.; Wolfmeir, H.; Heitz, J.
2014-11-01
The halogen chlorine is hard to detect in laser-induced breakdown spectroscopy (LIBS) mainly due to its high excited state energies of 9.2 and 10.4 eV for the most intense emission lines at 134.72 nm and 837.59 nm, respectively. We report on sensitive detection of Cl in industrial iron oxide Fe2O3 powder by single-pulse (SP) and dual-pulse (DP) LIBS measurements in the near infrared range in air. In compacted powder measured by SP excitation (Nd:YAG laser, 532 nm) Cl was detected with limit of detection LOD = 440 ppm and limit of quantitation LOQ = 720 ppm. Orthogonal DP LIBS was studied on pressed Fe2O3 pellets and Fe3O4 ceramics. The transmission of laser-induced plasma for orthogonal Nd:YAG 1064 nm and ArF 193 nm laser pulses showed a significant dependence on interpulse delay time (ipd) and laser wavelength (λL). The UV pulses (λL = 193 nm) were moderately absorbed in the plasma and the Cl I emission line intensity was enhanced while IR pulses (λL = 1064 nm) were not absorbed and Cl signals were not enhanced at ipd = 3 μs. The UV laser enhancement of Cl signals is attributed to the much higher signal/background ratio for orthogonal DP excitation compared to SP excitation and to the increased plasma temperature and electron number density. This enabled measurement at a very short delay time of td ≥ 0.1 μs with respect to the re-excitation pulse and detection of the very rapidly decaying Cl emission with higher efficiency.
Qiming, Chen; Tingting, Tao; Xiaomei, Bie; Yingjian, Lu; Fengxia, Lu; Ligong, Zhai; Zhaoxin, Lu
2015-08-01
Although several studies have reported PCR assays for distinguishing Cronobacter sakazakii from other species in the genus, reports regarding assay sensitivity and specificity, as well as applications for food testing, are lacking. Hence, the objective of this study was to develop a sensitive and reliable PCR-based method for detection of C. sakazakii by screening for specific target genes. The genome sequence of C. sakazakii in the GenBank database was compared with that of other organisms using BLAST. Thirty-eight DNA fragments unique to C. sakazakii were identified, and primers targeting these sequences were designed. Finally, 3 primer sets (CS14, CS21, and CS38) were found to be specific for C. sakazakii by PCR verification. The detection limit of PCR assays using the 3 pairs of primers was 1.35 pg/μL, 135 fg/μL, and 135 fg/μL, respectively, for genomic DNA, and 5.5×10(5), 5.5×10(3), 5.5×10(3) cfu/mL, respectively, using pure cultures of the bacteria, compared with 13.5 pg/μLand 5.5×10(5) cfu/mLfor primer set SpeCronsaka, which has been previously described. Cronobacter sakazakii were detected in artificially contaminated powdered infant formula (PIF) by PCR using primer sets CS21 and CS38 after 8h of enrichment. The detection limit was 5.5×10(-1) cfu/10g of PIF. Thus, the PCR assay can be used for rapid and sensitive detection of C. sakazakii in PIF. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Gumpu, Manju Bhargavi; Krishnan, Uma Maheswari; Rayappan, John Bosco Balaguru
2017-07-01
Intake of water contaminated with lead (Pb 2+ ) and mercury (Hg 2+ ) ions leads to various toxic effects and health issues. In this context, an amperometric urease inhibition-based biosensor was developed to detect Pb 2+ and Hg 2+ ions in water matrix. The modified Pt/CeO 2 /urease electrode was fabricated by immobilizing CeO 2 nanoparticles and urease using a semi-permeable adsorption layer of nafion. With urea as a substrate, urease catalytic activity was examined through cyclic voltammetry. Further, maximum amperometric inhibitive response of the modified Pt/CeO 2 /urease electrode was observed in the presence of Pb 2+ and Hg 2+ ions due to the urease inhibition at specific potentials of -0.03 and 0 V, respectively. The developed sensor exhibited a detection limit of 0.019 ± 0.001 μM with a sensitivity of 89.2 × 10 -3 μA μM -1 for Pb 2+ ions. A detection limit of 0.018 ± 0.003 with a sensitivity of 94.1 × 10 -3 μA μM -1 was achieved in detecting Hg 2+ ions. The developed biosensor showed a fast response time (<1 s) with a linear range of 0.5-2.2 and 0.02-0.8 μM for Pb 2+ and Hg 2+ ions, respectively. The modified electrode offered a good stability for 20 days with a good repeatability and reproducibility. The developed sensor was used to detect Pb 2+ and Hg 2+ ions contaminating Cauvery river water and the observed results were in good co-ordination with atomic absorption spectroscopic data.
Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell.
Bandura, Dmitry R; Baranov, Vladimir I; Tanner, Scott D
2002-04-01
A method of detection of ultratrace phosphorus and sulfur that uses reaction with O2 in a dynamic reaction cell (DRC) to oxidize S+ and P+ to allow their detection as SO+ and PO+ is described. The method reduces the effect of polyatomic isobaric interferences at m/z = 31 and 32 by detecting P+ and S+ as the product oxide ions that are less interfered. Use of an axial field in the DRC improves transmission of the product oxide ions 4-6 times. With no axial field, detection limits (3sigma, 5-s integration) of 0.20 and 0.52 ng/mL, with background equivalent concentrations of 0.53 and 4.8 ng/mL, respectively, are achieved. At an optimum axial field potential (200 V), the detection limits are 0.06 ng/mL for P and 0.2 ng/mL for S, respectively. The method is used for determining the degree of phosphorylation of beta-casein, and regular and dephosphorylated alpha-caseins at 10-1000 fmol/microL concentration, with 5-10% v/v organic sample matrix (acetonitrile, formic acid, ammonium bicarbonate). The measured degree of phosphorylation for beta-casein (4.9 phosphorus atoms/molecule) and regular alpha-casein (8.8 phoshorus atoms/molecule) are in good agreement with the structural data for the proteins. The P/S ratio for regular alpha-casein (1.58) is in good agreement with the ratio of the number of phosphorylation sites to the number of sulfur-containing amino acid residues cysteine and methionine. The P/S ratio for commercially available dephosphorylated alpha-casein is measured at 0.41 (approximately 26% residual phosphate).
Choi, Yeonim; Jeon, Bo-Young; Shim, Tae Sun; Jin, Hyunwoo; Cho, Sang-Nae; Lee, Hyeyoung
2014-12-01
Rapid, accurate detection of Mycobacterium tuberculosis is crucial in the diagnosis of tuberculosis (TB), but conventional diagnostic methods have limited sensitivity and specificity or are time consuming. A new highly sensitive nucleic acid amplification test, combined nested and real-time polymerase chain reaction (PCR) in a single tube (one-tube nested real-time PCR), was developed for detecting M. tuberculosis, which takes advantage of two PCR techniques, i.e., nested PCR and real-time PCR. One-tube nested real-time PCR was designed to have two sequential reactions with two sets of primers and dual probes for the insertion sequence (IS) 6110 sequence of M. tuberculosis in a single closed tube. The minimum limits of detection of IS6110 real-time PCR and IS6110 one-tube nested real-time PCR were 100 fg/μL and 1 fg/μL of M. tuberculosis DNA, respectively. AdvanSure TB/non-tuberculous mycobacteria (NTM) real-time PCR, IS6110 real-time PCR, and two-tube nested real-time PCR showed 100% sensitivity and 100% specificity for clinical M. tuberculosis isolates and NTM isolates. In comparison, the sensitivities of AdvanSure TB/NTM real-time PCR, single IS6110 real-time PCR, and one-tube nested real-time PCR were 91% (152/167), 94.6% (158/167), and 100% (167/167) for sputum specimens, respectively. In conclusion, IS6110 one-tube nested real-time PCR is useful for detecting M. tuberculosis due to its high sensitivity and simple manipulation. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Folkers, A.; Miebach, M.; Kleist, E.; Wildt, J.
2003-04-01
To study potential VOC uptake by plants we exposed sunflower (Helianthus annuus) to different VOC in continuously stirred tank reactors. For many VOC like methanol, ethanol, acetone, methylvinylketone, isoprene or limonene no uptake was detectable within the accuracy of our analytic set up. Other VOC like hexanal, octanal, (E)-3-hexenol and nopinone were taken up by sunflower. The uptake was related to stomatal aperture. Obviously, these VOC enter the plants through stomata. In case of hexanal, octanal, and (E)-3-hexenol the uptake was only limited by stomatal aperture implying that these VOC are rapidly metabolised. For nopinone the uptake seems to be limited by a slow metabolization. Estimations of deposition velocities showed that dry deposition of these compounds cannot be neglected as sink if diffusion through stomata is the limiting step for dry deposition. In such cases the lifetime with respect to dry deposiotion is comparable to the lifetime with respect to oxidation by hydroxyl radicals.
Giacomo, Della Riccia; Stefania, Del Zotto
2013-12-15
Fumonisins are mycotoxins produced by Fusarium species that commonly live in maize. Whereas fungi damage plants, fumonisins cause disease both to cattle breedings and human beings. Law limits set fumonisins tolerable daily intake with respect to several maize based feed and food. Chemical techniques assure the most reliable and accurate measurements, but they are expensive and time consuming. A method based on Near Infrared spectroscopy and multivariate statistical regression is described as a simpler, cheaper and faster alternative. We apply Partial Least Squares with full cross validation. Two models are described, having high correlation of calibration (0.995, 0.998) and of validation (0.908, 0.909), respectively. Description of observed phenomenon is accurate and overfitting is avoided. Screening of contaminated maize with respect to European legal limit of 4 mg kg(-1) should be assured. Copyright © 2013 Elsevier Ltd. All rights reserved.
46 CFR 161.002-2 - Types of fire-protective systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., but not be limited to, automatic fire and smoke detecting systems, manual fire alarm systems, sample... unit, fire detectors, smoke detectors, and audible and visual alarms distinct in both respects from the alarms of any other system not indicating fire. (c) Manual fire alarm systems. For the purpose of this...
USDA-ARS?s Scientific Manuscript database
Trunk diseases are factors that limit sustainability of vineyards worldwide. Bot canker and Eutypa dieback are caused by several fungi belonging to the Botryosphaericeae and Diatrypaceae, respectively with Diplodia seriata and Eutypa lata being two of the most common species. Previous information in...
Shinde, P B; Aragade, P D; Agrawal, M R; Deokate, U A; Khadabadi, S S
2011-01-01
The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F254. The mobile phase used was mixture of ethyl acetate: methanol: toluene: water (4:1:1:0.5 v/v/v/v). The detection of spots was carried out at 320 nm using absorbance reflectance mode. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot for withanolide A and 50 to 350 ng/spot for bacoside A. The limit of detection and limit of quantification for the withanolide A were found to be 3.05 and 10.06 ng/spot, respectively and for bacoside A 8.3 and 27.39 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation. PMID:22303073
Shinde, P B; Aragade, P D; Agrawal, M R; Deokate, U A; Khadabadi, S S
2011-03-01
The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F(254). The mobile phase used was mixture of ethyl acetate: methanol: toluene: water (4:1:1:0.5 v/v/v/v). The detection of spots was carried out at 320 nm using absorbance reflectance mode. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot for withanolide A and 50 to 350 ng/spot for bacoside A. The limit of detection and limit of quantification for the withanolide A were found to be 3.05 and 10.06 ng/spot, respectively and for bacoside A 8.3 and 27.39 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.
Erarpat, Sezin; Özzeybek, Gözde; Chormey, Dotse Selali; Bakırdere, Sezgin
2017-12-01
In this study, dispersive liquid-liquid microextraction (DLLME) and slotted quartz tube (SQT) were coupled to flame atomic absorption spectrometry (FAAS) to increase the sensitivity of lead. Conditions such as the formation of the lead-dithizone complex, efficiency of the DLLME method and the output of the SQT were systematically optimized to improve the detection limit for the analyte. The conventional FAAS system was improved upon by about 3.0 times with SQT-FAAS, 32 times with DLLME-FAAS and 142 times with DLLME-SQT-FAAS. The method was applicable over a wide linear range (10-500 μg L -1 ). The limit of detection (LOD) determined by DLLME-SQT-FAAS for seawater and mussel were 2.7 μg L -1 and 270 μg kg -1 , respectively. The percent recoveries obtained for mussel and seawater samples (spiked at 20 and 50 μg L -1 ) were 95-96% and 98-110%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hanafi, Ahmad; Dasenaki, Marilena; Bletsou, Anna; Thomaidis, Nikolaos S
2018-02-01
Two QuEChERS-based methods were developed and validated, using liquid chromatography-tandem mass spectrometric detection, in order to accurately determine residues of imidacloprid and oxamyl in green beans and chili peppers after treatment via irrigation system under field conditions in Egyptian farms. The validation included experiments for specificity, linearity, trueness, precision, matrix effect and limits of detection and quantification according to European Commission standards. The dissipation rates of both pesticides in green beans and chili peppers were studied and the pre-harvest intervals (PHIs) were calculated. The LOQ values of imidacloprid were 0.47 and 2.6μg/kg in green beans and chili peppers, respectively, while for oxamyl the LOQs were 2.9 and 0.67μg/kg, respectively. No PHI of imidacloprid is required, while for oxamyl it was found that still after 21days, its residues' concentration on both crops was significantly higher than the maximum residue limit. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wang, Ze Ping; Shen, Jian Zhong; Linhardt, Robert J; Jiang, Hui; Cheng, Lin Li
2017-03-01
Hainanmycin is a new veterinary polyether antibiotic and has few sensitive analytical method in present days. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) relying on multiple reaction monitoring (MRM) detection was developed for analysis of hainanmycin in animal feed. Feed samples were extracted with ethyl acetate and purified by two steps of liquid-liquid extraction (LLE) to get rid of water solvable matrix and lipids one by one. The final simple was analyzed by LC-MS/MS. The LC mobile phase was composed of 0.1% aqueous formic acid and 0.1% formic acidified acetonitrile by gradient elution. Average recoveries ranged from 74.22% to 87.85%, as determined by spiking with 2.0 (LOQ) ∼2500μgkg -1 of hainanmycin. The inter-day and intra-day coefficient of variation was 9.21% to 11.77% and 7.67% to 13.49%, respectively. The limit of detection (LOD) and the limit of quantitation (LOQ) were 0.36μgkg -1 and 2.0μgkg -1 , respectively. Copyright © 2016. Published by Elsevier B.V.
Iamanaka, Beatriz Thie; Nakano, Felipe; Lemes, Daniel Ponciano; Ferranti, Larissa Souza; Taniwaki, Marta Hiromi
2014-01-01
A high-performance liquid chromatography-fluorescence (HPLC-FD) method for aflatoxin quantification in brazil nuts was developed. Samples of brazil nuts collected in Brazilian markets were extracted with methanol:water and cleaned using an immunoaffinity column. Aflatoxins were eluted with methanol and a post-column derivatisation was performed with bromine, using a Kobra Cell system. The optimised method for total aflatoxins was sensitive, with detection and quantification limits of 0.05 and 0.25 µg kg⁻¹, respectively. The method was accurate, with recovery values of 87.6%; 85.3% and 85.0% for 0.5, 5.0 and 14.6 µg kg⁻¹ spiked levels, respectively. It was shown that the method was applicable to brazil nuts. From a total of 95 brazil nut samples analysed from 21 São Paulo supermarket samples and 51 Manaus and 23 Belém street markets samples, 37.9% showed detectable levels of aflatoxins and three exceeded the recommended Codex Alimentarius limit of 10 µg kg⁻¹ for ready-to-eat brazil nuts.
Establishing the behavioural limits for countershaded camouflage.
Penacchio, Olivier; Harris, Julie M; Lovell, P George
2017-10-20
Countershading is a ubiquitous patterning of animals whereby the side that typically faces the highest illumination is darker. When tuned to specific lighting conditions and body orientation with respect to the light field, countershading minimizes the gradient of light the body reflects by counterbalancing shadowing due to illumination, and has therefore classically been thought of as an adaptation for visual camouflage. However, whether and how crypsis degrades when body orientation with respect to the light field is non-optimal has never been studied. We tested the behavioural limits on body orientation for countershading to deliver effective visual camouflage. We asked human participants to detect a countershaded target in a simulated three-dimensional environment. The target was optimally coloured for crypsis in a reference orientation and was displayed at different orientations. Search performance dramatically improved for deviations beyond 15 degrees. Detection time was significantly shorter and accuracy significantly higher than when the target orientation matched the countershading pattern. This work demonstrates the importance of maintaining body orientation appropriate for the displayed camouflage pattern, suggesting a possible selective pressure for animals to orient themselves appropriately to enhance crypsis.
Eichbaum, Kathrin; Brinkmann, Markus; Buchinger, Sebastian; Reifferscheid, Georg; Hecker, Markus; Giesy, John P; Engwall, Magnus; van Bavel, Bert; Hollert, Henner
2014-07-15
Use of in vitro assays as screening tool to characterize contamination of a variety of environmental matrices has become an increasingly popular and powerful toolbox in the field of environmental toxicology. While bioassays cannot entirely substitute analytical methods such as gas chromatography-mass spectrometry (GC-MS), the increasing improvement of cell lines and standardization of bioassay procedures enhance their utility as bioanalytical pre-screening tests prior to more targeted chemical analytical investigations. Dioxin-receptor-based assays provide a holistic characterization of exposure to dioxin-like compounds (DLCs) by integrating their overall toxic potential, including potentials of unknown DLCs not detectable via e.g. GC-MS. Hence, they provide important additional information with respect to environmental risk assessment of DLCs. This review summarizes different in vitro bioassay applications for detection of DLCs and considers the comparability of bioassay and chemical analytically derived toxicity equivalents (TEQs) of different approaches and various matrices. These range from complex samples such as sediments through single reference to compound mixtures. A summary of bioassay derived detection limits (LODs) showed a number of current bioassays to be equally sensitive as chemical methodologies, but moreover revealed that most of the bioanalytical studies conducted to date did not report their LODs, which represents a limitation with regard to low potency samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Srivastava, Ashutosh K; Trivedi, Purushottam; Srivastava, M K; Lohani, M; Srivastava, Laxman Prasad
2011-05-01
The study was conducted on 20 vegetables including leafy, root, modified stem, and fruity vegetables like bitter gourd, jack fruit, french-bean, onion, colocassia, pointed gourd, capsicum, spinach, potato, fenugreek seeds, carrot, radish, cucumber, beetroot, brinjal, cauliflower, cabbage, tomato, okra, and bottle gourd. Forty-eight pesticides including 13 organochlorines (OCs), 17 organophosphates (OPs), 10 synthetic pyrethriods (SPs), and eight herbicides (H) pesticides were analyzed. A total number of 60 samples, each in triplicates, were analyzed using Quick, Easy, Cheap, Effective, Rugged, and Safe method. The quantification was done by GC-ECD/NPD. The recovery varies from 70.22% to 96.32% with relative standard deviation (RSD) of 15%. However the limit of detection ranged from 0.001-0.009 mg kg(-1)for OCs, SPs, OPs, and H, respectively. Twenty-three pesticides were detected from total 48 analyzed pesticides in the samples with the range of 0.005-12.35 mg kg(-1). The detected pesticides were: Σ-HCH, Dicofol, Σ-Endosulfan, Fenpropathrin, Permethrin-II, β-cyfluthrin-II, Fenvalerate-I, Dichlorvos, Dimethoate, Diazinon, Malathion, Chlorofenvinfos, Anilophos, and Dimethachlor. In some vegetables like radish, cucumber, cauliflower, cabbage, and okra, the detected pesticides (Σ-HCH, Permethrin-II, Dichlorvos, and Chlorofenvinfos) were above maximum residues limit (MRL) (PFA 1954). However, in other vegetables the level of pesticide residues was either below detection limit or MRL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karimi, A.R.
In this study a method for the measurement of uranium in natural waters at sub-ppB concentration levels by the separation and determination of U/sup 4 +/ and UO/sub 2//sup 2 +/ species is proposed. Reversed phase high performance liquid chromatography, followed by a post-column reaction and a sensitive UV-visible detection system was the method of choice to determine qualitatively and quantitatively the two uranium species. Also a cation-exchange and fluorescence detection system was studied for separation and determination of UO/sub 2//sup 2 +/ ions. Uranyl ion was selectively complexed with L-phenylalanine moetie in the sample solution containing U/sup 4 +/more » ions. Uranium (IV)/U(VI)-ligand was separated on a C/sub 18/ column with acetate buffer. Hexanesulfonate was found to be the choice for ion-pair reagent. The separation was best done with the acetate buffer at .01 M concentration and pH of 3.5. Absorption of the two species were measured after a post-column reaction with Arsenazo-III. Chromatographic parameters were calculated and a calibration curves were constructed. The detection limit for the procedure was 0.7 ..mu..g/mo and 1.2..mu..g/ml for U(IV) and U(VI) respectively. When U(VI) was separated on the cation-exchange column the limit of detection was calculated to be 1 ..mu..g/ml. The direct fluorometric method for U(VI) measurement results in a detection limit of 2 ppB and upper concentration limit of 2 ppM. The effect of interfering ions in the direct method of determination could be eliminated by dilution of sample solution.« less
[A Duplex PCR Method for Detection of Babesia caballi and Theileria equi].
Zhang, Yang; Zhang, Yu-ting; Wang, Zhen-bao; Bolati; Li, Hai; Bayinchahan
2015-04-01
To develop a duplex PCR assay for detection of Babesia caballi and Theileria equi. Two pairs of primers were designed according to the BC48 gene of B. caballi and 18 s rRNA gene of T. equi, and a duplex PCR assay was developed by the optimization of reaction conditions. The specificity, sensitivity and reliability of the method were tested. The horse blood samples of suspected cases were collected from Yili region, and detected by the duplex PCR, microspopy, conventional PCR, and fluorescence quantitative PCR, and the results were compared. Using the duplex PCR assay, the specific fragments of 155 bp and 280 bp were amplified from DNA samples of B. caballi and T. equi, respectively. No specific fragment was amplified from DNA samples of B. bigemina, Theilerdia annulata, Theilerdia sergenti, Toxoplasma gondii, Neospora caninum, and Trypanosoma evansi. The limit of detection was 4.85 x 10(5) copies/L for B. caballi DNA and 4.85 x 10(4) copies/µl for T. equi DNA, respectively. Among the 24 blood samples, 11 were found B. caballi-positive by the duplex PCR assay, and 18 were T. equi-positive. The coincidence rate of microscopy, conventional PCR, and fluorescence quantitative PCR with duplex PCR was 91.7% (22/24), 95.8% (23/24), and 95.8% (23/24), respectively. A duplex PCR assay for simultaneous detection of B. caballi and T. equi is established.
Mashhadizadeh, Mohammad Hossein; Amoli-Diva, Mitra; Pourghazi, Kamyar
2013-12-13
A new, simple, fast, and environmental friendly sample preconcentration technique based on the modified Fe3O4 nanoparticles has been developed for extraction, and determination of ochratoxin A (OTA). Magnetic nanoparticles were coated with 3-(trimethoxysilyl)-1-propanethiol and modified by ethylene glycol bis-mercaptoacetate. Transmission electron microscopy, X-ray diffraction, and Fourier transform infrared spectrometry were used to characterize the adsorbents and the main parameters affecting the extraction and desorption efficiencies, such as pH of sample solution, sample volume, desorption conditions, extraction and desorption times, salt addition, and co-existing interferences have been investigated and established. Under optimal conditions, OTA was extracted and analyzed using high performance liquid chromatography with fluorescence detection. The mobile phase consists of acetonitrile:water:acetic acid (99:99:2, v/v/v) and fluorescence detection was performed with excitation and emission wavelengths at 333 and 477nm, respectively. An enrichment factor of 24 was achieved for OTA with relative standard deviation of <7%. The proposed method was applied to twenty samples of cereals (rice, wheat, and corn). The limits of detection of 0.06, 0.03, and 0.05ngmL(-1) and limits of quantitation of 0.19, 0.11, and 0.15ngmL(-1), were found for rice, wheat, and corn samples, respectively. The recoveries of OTA for spiked samples were ranged from 87 to 93%. Copyright © 2013 Elsevier B.V. All rights reserved.
Rodrigues, Núbia Fernanda Marinho; Neto, Sakae Yotsumoto; Luz, Rita de Cássia Silva; Yamanaka, Hideko
2018-01-01
A renewable, disposable, low cost, and sensitive sensor for the detection of organophosphorus pesticides was constructed by immobilizing the acetylcholinesterase enzyme (AChE), via glutaraldehyde, on magnetic iron nanoparticles (Fe3O4) previously synthesized and functionalized with chitosan (CS). The sensor was denoted AChE/CS/Fe3O4. The magnetic nanoparticles were characterized by Fourier transform infrared spectroscopy and transmission electron microscopy. Acetylthiocholine (ATCh) was incubated with AChE/CS/Fe3O4 and attached to a screen-printed electrode using a magnet. The oxidation of thiocholine (from ATCh hydrolysis) was monitored at an applied potential of +0.5 V vs. Ag/AgCl(KClsat) in 0.1 mol L−1 phosphate buffer solution (pH 7.5) as the supporting electrolyte. A mixture of the pesticide malathion and ATCh was investigated using the same procedure, and the results were compared and expressed as inhibition percentages. For determination of malathion, the proposed sensor presented a linear response in the range from 0.5 to 20 nmol L−1 (R = 0.9942). The limits of detection (LOD) and quantification (LOQ) were 0.3 and 0.8 nmol L−1, respectively. Real samples were also investigated, with recovery values of 96.0% and 108.3% obtained for tomato and pond water samples, respectively. The proposed sensor is a feasible option for malathion detection, offering a linear response, good sensitivity, and a low detection limit. PMID:29438301
Fully integrated lab-on-a-disc for nucleic acid analysis of food-borne pathogens.
Kim, Tae-Hyeong; Park, Juhee; Kim, Chi-Ju; Cho, Yoon-Kyoung
2014-04-15
This paper describes a micro total analysis system for molecular analysis of Salmonella, a major food-borne pathogen. We developed a centrifugal microfluidic device, which integrated the three main steps of pathogen detection, DNA extraction, isothermal recombinase polymerase amplification (RPA), and detection, onto a single disc. A single laser diode was utilized for wireless control of valve actuation, cell lysis, and noncontact heating in the isothermal amplification step, thereby yielding a compact and miniaturized system. To achieve high detection sensitivity, rare cells in large volumes of phosphate-buffered saline (PBS) and milk samples were enriched before loading onto the disc by using antibody-coated magnetic beads. The entire procedure, from DNA extraction through to detection, was completed within 30 min in a fully automated fashion. The final detection was carried out using lateral flow strips by direct visual observation; detection limit was 10 cfu/mL and 10(2) cfu/mL in PBS and milk, respectively. Our device allows rapid molecular diagnostic analysis and does not require specially trained personnel or expensive equipment. Thus, we expect that it would have an array of potential applications, including in the detection of food-borne pathogens, environmental monitoring, and molecular diagnostics in resource-limited settings.
SUN, Yu-Ling; YEN, Chon-Ho; TU, Ching-Fu
2013-01-01
ABSTRACT Loop-mediated isothermal amplification (LAMP) combined with enzyme-linked immunosorbent assay (LAMP–ELISA) and with lateral flow dipstick (LAMP–LFD) are rapid, sensitive and specific methods for the visual detection of clinical pathogens. In this study, LAMP–ELISA and LAMP–LFD were developed for the visual detection of canine parvovirus (CPV). For LAMP, a set of four primers (biotin-labeled forward inner primers) was designed to specifically amplify a region of the VP2 gene of CPV. The optimum time and temperature for LAMP were 60 min and 65°C, respectively. The specific capture oligonucleotide probes, biotin-labeled CPV probe for LAMP–ELISA and fluorescein isothiocyanate-labeled CPV probe for LAMP–LFD were also designed for hybridization with LAMP amplicons on streptavidin-coated wells and LFD strips, respectively. For the comparison of detection sensitivity, conventional PCR and LAMP for CPV detection were also performed. The CPV detection limits by PCR, PCR–ELISA, LAMP, LAMP–ELISA and LAMP–LFD were 102, 102, 10−1, 10−1 and 10−1 TCID50/ml, respectively. In tests using artificially contaminated dog fecal samples, the samples with CPV inoculation levels of ≥1 TCID50/ml gave positive results by both LAMP–ELISA and LAMP–LFD. Our data indicated that both LAMP–ELISA and LAMP–LFD are promising as rapid, sensitive and specific methods for an efficient diagnosis of CPV infection. PMID:24334855
NASA Astrophysics Data System (ADS)
Wardani, Devy P.; Arifin, Muhammad; Suharyadi, Edi; Abraha, Kamsul
2015-05-01
Gelatin is a biopolymer derived from collagen that is widely used in food and pharmaceutical products. Due to some religion restrictions and health issues regarding the gelatin consumption which is extracted from certain species, it is necessary to establish a robust, reliable, sensitive and simple quantitative method to detect gelatin from different parent collagen species. To the best of our knowledge, there has not been a gelatin differentiation method based on optical sensor that could detect gelatin from different species quantitatively. Surface plasmon resonance (SPR) based biosensor is known to be a sensitive, simple and label free optical method for detecting biomaterials that is able to do quantitative detection. Therefore, we have utilized SPR-based biosensor to detect the differentiation between bovine and porcine gelatin in various concentration, from 0% to 10% (w/w). Here, we report the ability of SPR-based biosensor to detect difference between both gelatins, its sensitivity toward the gelatin concentration change, its reliability and limit of detection (LOD) and limit of quantification (LOQ) of the sensor. The sensor's LOD and LOQ towards bovine gelatin concentration are 0.38% and 1.26% (w/w), while towards porcine gelatin concentration are 0.66% and 2.20% (w/w), respectively. The results show that SPR-based biosensor is a promising tool for detecting gelatin from different raw materials quantitatively.
Flow Cytometry Detection of Infectious Rotaviruses in Environmental and Clinical Samples
Abad, F. Xavier; Pintó, Rosa M.; Bosch, Albert
1998-01-01
A method for the detection of infectious human rotaviruses based on infection of CaCo-2 cells and detection of infected cells by indirect immunofluorescence and flow cytometry (IIF-FC) has been developed. The technique was validated by performing a seminested reverse transcription-PCR assay with sorted cell populations. The efficiency of the procedure has been compared with that of the standard method of infection of MA104 cells and ulterior detection by IIF and optical microscopy (IIF-OM) and with that of infection of MA104 cells and detection by IIF-FC. The limit of sensitivity for the detection of the cell-adapted strain Itor P13, expressed as the most probable number of cytopathogenic units, was established as 200 and 2 for MA104 and CaCo-2 cells, respectively, by the IIF-FC method. The ratio of infectious virus particles to total virus particles for a wild-type rotavirus was determined to be 1/2 × 106 and 1/2 × 104 for IIF-OM with MA104 cells and IIF-FC with CaCo-2 cells, respectively. The use of IIF-FC with CaCo-2 cells was tested with fecal and water samples and proved to be more effective than the standard procedure for rotavirus detection. PMID:9647805
[Detection of recombinant-DNA in foods from stacked genetically modified plants].
Sorokina, E Iu; Chernyshova, O N
2012-01-01
A quantitative real-time multiplex polymerase chain reaction method was applied to the detection and quantification of MON863 and MON810 in stacked genetically modified maize MON 810xMON 863. The limit of detection was approximately 0,1%. The accuracy of the quantification, measured as bias from the accepted value and the relative repeatability standard deviation, which measures the intra-laboratory variability, were within 25% at each GM-level. A method verification has demonstrated that the MON 863 and the MON810 methods can be equally applied in quantification of the respective events in stacked MON810xMON 863.
NASA Astrophysics Data System (ADS)
Mu, Luye; Droujinine, Ilia; Rajan, Nitin; Sawtelle, Sonya; Reed, Mark
2015-03-01
The ability to measure enzyme-substrate interactions is essential in areas such as diagnostics, treatment, and biochemical screens. Many enzymatic reactions alter the pH of its environment, suggesting of a simple and direct method for detection. We show the ability of Al2O3-coated Si nanoribbon field-effect transistor biosensors to sensitively measure various aspects of enzyme-substrate interactions through measuring the pH. Urea in phosphate buffered saline (PBS) and penicillinase in PBS and urine were measured to limits of <200 μM and 0.02 units/mL, respectively. We also show the ability to extract accurate kinetics from the interaction of acetylcholine and its esterase. Prior work on FET sensors has been limited by the use of surface functionalization, which not only alters enzyme-substrate affinity, but also makes enzyme activity quantification difficult. Our method involves direct detection of reactions in solution without requiring alteration to the reactants, allowing us to obtain repeatable results and sensitive limits of detection. This method is a simple, inexpensive, and effective platform for detection of enzymatic reactions, and can be readily generalized to many unrelated classes of reactants. This work was supported in part by U.S. Army Research Office and Air Force Research Laboratory.
Immuno-analysis of microparticles: probing at the limits of detection
Latham, Sharissa L.; Tiberti, Natalia; Gokoolparsadh, Naveena; Holdaway, Karen; Olivier Couraud, Pierre; Grau, Georges E. R.; Combes, Valery
2015-01-01
Microparticle (MP) research is clouded by debate regarding the accuracy and validity of flow cytometry (FCM) as an analytical methodology, as it is influenced by many variables including the pre-analytical conditions, instruments physical capabilities and detection parameters. This study utilises a simplistic in vitro system for generating MP, and through comparative analysis with immuno-electron microscopy (Immuno-EM) assesses the strengths and limitations of probe selection and high-sensitivity FCM. Of the markers examined, MP were most specifically labelled with phosphatidylserine ligands, annexin V and lactadherin, although only ~60% MP are PS positive. Whilst these two ligands detect comparable absolute MP numbers, they interact with the same population in distinct manners; annexin V binding is enhanced on TNF induced MP. CD105 and CD54 expression were, as expected, consistent and enhanced following TNF activation respectively. Their labelling however accounted for as few as 30–40% of MP. The greatest discrepancies between FCM and I-EM were observed in the population solely labelled for the surface antigen. These findings demonstrate that despite significant improvements in resolution, high-sensitivity FCM remains limited in detecting small-size MP expressing low antigen levels. This study highlights factors to consider when selecting endothelial MP probes, as well as interpreting and representing data. PMID:26553743
Tang, Yulu; Zhong, Bifeng; Qu, Bing; Feng, Shujin; Ding, Sanglan; Su, Shijun; Li, Zhi; Gan, Zhiwei
2017-05-24
A total of 28 groundwater, paired farmland soil, lettuce, and its rhizosphere soil samples were collected from Chengdu, China to detect perchlorate levels and to evaluate the relationships of perchlorate concentrations among these matrices. The perchlorate concentrations in the groundwater, farmland soil, lettuce, and rhizosphere soil samples ranged from below detection limit to 60.2 μg L -1 , from below detection limit to 249 μg kg -1 dry weight (dw), from 2.07 to 1010 μg kg -1 wet weight, and from below detection limit to 314 μg kg -1 dw, respectively. Significant correlation was found in the perchlorate levels among the farmland soil, lettuce, and rhizosphere soil, suggesting that they have common pollution sources, or perchlorate might transfer from farmland soil-rhizosphere soil-plant. However, there is no significant correlation between groundwater and the other three matrices, indicating that infiltration from perchlorate contaminated farmland soil was not the predominant source for groundwater pollution in Chengdu. The perchlorate concentrations in the farmland soil and lettuce samples were significantly higher than those in the rhizosphere soil, primarily due to uptake of perchlorate through the rhizosphere micro-environment by lettuce, or accelerated degradation by rhizospheric microorganisms, which contributed more needs further investigation.
Simultaneous multielement atomic absorption spectrometry with graphite furnace atomization
NASA Astrophysics Data System (ADS)
Harnly, James M.; Miller-Ihli, Nancy J.; O'Haver, Thomas C.
The extended analytical range capability of a simultaneous multielement atomic absorption continuum source spectrometer (SIMAAC) was tested for furnace atomization with respect to the signal measurement mode (peak height and area), the atomization mode (from the wall or from a platform), and the temperature program mode (stepped or ramped atomization). These parameters were evaluated with respect to the shapes of the analytical curves, the detection limits, carry-over contamination and accuracy. Peak area measurements gave more linear calibration curves. Methods for slowing the atomization step heating rate, the use of a ramped temperature program or a platform, produced similar calibration curves and longer linear ranges than atomization with a stepped temperature program. Peak height detection limits were best using stepped atomization from the wall. Peak area detection limits for all atomization modes were similar. Carry-over contamination was worse for peak area than peak height, worse for ramped atomization than stepped atomization, and worse for atomization from a platform than from the wall. Accurate determinations (100 ± 12% for Ca, Cu, Fe, Mn, and Zn in National Bureau of Standards' Standard Reference Materials Bovine Liver 1577 and Rice Flour 1568 were obtained using peak area measurements with ramped atomization from the wall and stepped atomization from a platform. Only stepped atomization from a platform gave accurate recoveries for K. Accurate recoveries, 100 ± 10%, with precisions ranging from 1 to 36 % (standard deviation), were obtained for the determination of Al, Co, Cr, Fe, Mn, Mo, Ni. Pb, V and Zn in Acidified Waters (NBS SRM 1643 and 1643a) using stepped atomization from a platform.
Wang, Ke; Li, Nan; Zhang, Jing; Zhang, Zhiqi; Dang, Fuquan
2017-01-15
In this work, we proposed a novel and facile method to monitor oxidase activities based on size-selective fluorescent quantum dot (QD)@metal-organic framework (MOF) core-shell nanocomposites (CSNCPs). The CSNCPs were synthesized from ZIF-8 and CdTe QDs in aqueous solution in 40min at room temperature with stirring. The prepared CdTe@ZIF-8 CSNCPs , which have excellent water dispersibility and stability, displays distinct fluorescence responses to hole scavengers of different molecular sizes (e.g., H 2 O 2 , substrate, and oxidase) due to the aperture limitation of the ZIF-8 shell. H 2 O 2 can efficiently quench the fluorescence of CdTe@ZIF-8 CSNCPs over a linearity range of 1-100nM with a detection limit of 0.29nM, whereas large molecules such as substrate and oxidase have very little effect on its fluorescence. Therefore, the highly sensitive detection of oxidase activities was achieved by monitoring the fluorescence quenching of CdTe@ZIF-8 CSNCPs by H 2 O 2 produced in the presence of substrate and oxidase, which is proportional to the oxidase activities. The linearity ranges of the uricase and glucose oxidase activity are 0.1-50U/L and 1-100U/L, respectively, and their detection limits are 0.024U/L and 0.26U/L, respectively. Therefore, the current QD@MOF CSNCPs based sensing system is a promising, widely applicable means of monitoring oxidase activities in biochemical research. Copyright © 2016 Elsevier B.V. All rights reserved.
KRAS mutations in blood circulating cell-free DNA: a pancreatic cancer case-control
Le Calvez-Kelm, Florence; Foll, Matthieu; Wozniak, Magdalena B.; Delhomme, Tiffany M.; Durand, Geoffroy; Chopard, Priscilia; Pertesi, Maroulio; Fabianova, Eleonora; Adamcakova, Zora; Holcatova, Ivana; Foretova, Lenka; Janout, Vladimir; Vallee, Maxime P.; Rinaldi, Sabina; Brennan, Paul; McKay, James D.; Byrnes, Graham B.; Scelo, Ghislaine
2016-01-01
The utility of KRAS mutations in plasma circulating cell-free DNA (cfDNA) samples as non-invasive biomarkers for the detection of pancreatic cancer has never been evaluated in a large case-control series. We applied a KRAS amplicon-based deep sequencing strategy combined with analytical pipeline specifically designed for the detection of low-abundance mutations to screen plasma samples of 437 pancreatic cancer cases, 141 chronic pancreatitis subjects, and 394 healthy controls. We detected mutations in 21.1% (N=92) of cases, of whom 82 (89.1%) carried at least one mutation at hotspot codons 12, 13 or 61, with mutant allelic fractions from 0.08% to 79%. Advanced stages were associated with an increased proportion of detection, with KRAS cfDNA mutations detected in 10.3%, 17,5% and 33.3% of cases with local, regional and systemic stages, respectively. We also detected KRAS cfDNA mutations in 3.7% (N=14) of healthy controls and in 4.3% (N=6) of subjects with chronic pancreatitis, but at significantly lower allelic fractions than in cases. Combining cfDNA KRAS mutations and CA19-9 plasma levels on a limited set of case-control samples did not improve the overall performance of the biomarkers as compared to CA19-9 alone. Whether the limited sensitivity and specificity observed in our series of KRAS mutations in plasma cfDNA as biomarkers for pancreatic cancer detection are attributable to methodological limitations or to the biology of cfDNA should be further assessed in large case-control series. PMID:27705932
Doret, Muriel; Cartier, Régine; Miribel, Juliette; Massardier, Jérome; Massoud, Mona; Bordes, Agnès; Moret, Stéphanie; Gaucherand, Pascal
2013-12-01
Previable premature rupture of the membranes (pPROM), occurring before 24WG, is associated with a 25% neonatal survival rate. This terrible prognosis may lead to elective pregnancy termination on parents' request. Therefore, certain diagnosis is essential but remains difficult in about 10% of patients. Bed-side biochemical tests developed to help in diagnosis had never been evaluated in early pregnancies. This study aimed to evaluate and compare the in vitro sensitivity, detection limit, reaction time and consistency of AmniSure detecting placental alpha microglobulin-1 (PAMG-1) and actim PROM detecting Insulin Growth Factor Binding Protein-1 (IGFBP-1) in amniotic fluid between 15 and 20weeks of gestation (WG). Samples of amniotic fluid were collected by amniocentesis performed between 15 and 20 completed WG in 55 patients. Dilution series were prepared and both tests were performed twice at each dilution. In vitro sensitivity, detection limit, and reaction time were evaluated and compared in serial dilution. A total of 460 AmniSure and 476 actim PROM tests were performed. Both tests' in vitro sensitivity was 100% at dilution 1:20 and remained up to 90% until dilution 1:80. In vitro sensitivities were not different at any dilution. Detection limit and consistency were similar for both tests at all dilution. Actim PROM reaction time was shorter than AmniSure at all dilutions, except 1:320 (p<0.05). PAMG-1 and IGFBP-1 can be detected in amniotic fluid between 15 and 20 completed WG, using respectively AmniSure and actim PROM. © 2013.
Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias
2016-05-20
To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.
Radu, Maria D; Räber, Lorenz; Heo, Jungho; Gogas, Bill D; Jørgensen, Erik; Kelbæk, Henning; Muramatsu, Takashi; Farooq, Vasim; Helqvist, Steffen; Garcia-Garcia, Hector M; Windecker, Stephan; Saunamäki, Kari; Serruys, Patrick W
2014-01-22
Angiographic evidence of edge dissections has been associated with a risk of early stent thrombosis. Optical coherence tomography (OCT) is a high-resolution technology detecting a greater number of edge dissections--particularly non-flow-limiting--compared to angiography. Their natural history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. Edge dissections were defined as disruptions of the luminal surface in the 5 mm segments proximal and distal to the stent, and categorised as flaps, cavities, double-lumen dissections or fissures. Qualitative and quantitative OCT analyses were performed every 0.5 mm at baseline and one year, and clinical outcomes were assessed. Sixty-three lesions (57 patients) were studied with OCT at baseline and one-year follow-up. Twenty-two non-flow-limiting edge dissections in 21 lesions (20 patients) were identified by OCT; only two (9%) were angiographically visible. Flaps were found in 96% of cases. The median longitudinal dissection length was 2.9 mm (interquartile range [IQR] 1.6-4.2 mm), whereas the circumferential and axial extensions amounted to 1.2 mm (IQR: 0.9-1.7 mm) and 0.6 mm (IQR: 0.4-0.7 mm), respectively. Dissections extended into the media and adventitia in seven (33%) and four (20%) cases, respectively. Eighteen (82%) OCT-detected edge dissections were also evaluated with intravascular ultrasound which identified nine (50%) of these OCT-detected dissections. No stent thrombosis or target lesion revascularisation occurred up to one year. At follow-up, 20 (90%) edge dissections were completely healed on OCT. The two cases exhibiting persistent dissection had the longest flaps (2.81 mm and 2.42 mm) at baseline. OCT-detected edge dissections which are angiographically silent in the majority of cases are not associated with acute stent thrombosis or restenosis up to one-year follow-up.
Nunes, Kátia S D; Assalin, Márcia R; Vallim, José H; Jonsson, Claudio M; Queiroz, Sonia C N; Reyes, Felix G R
2018-01-01
A multiresidue method for detecting and quantifying sulfonamides (sulfapyridine, sulfamerazine, sulfathiazole, sulfamethazine, sulfadimethoxine, sulfamethoxazole, and sulfamethoxypyridazine) and trimethoprim in tilapia fillet ( Oreochromis niloticus ) using liquid chromatography coupled to mass spectrometry was developed and validated. The sample preparation was optimized using the QuEChERS approach. The chromatographic separation was performed using a C18 column and 0.1% formic acid in water and acetonitrile as the mobile phase in the isocratic elution mode. Method validation was performed based on the Commission Decision 2002/657/EC and Brazilian guideline. The validation parameters evaluated were linearity ( r ≥ 0.99); limits of detection (LOD) and quantification (LOQ), 1 ng·g -1 and 5 ng·g -1 , respectively; intraday and interdays precision (CV lower than 19.4%). The decision limit (CC α 102.6-120.0 ng·g -1 and 70 ng·g -1 for sulfonamides and trimethoprim, respectively) and detection capability (CC β 111.7-140.1 ng·g -1 and 89.9 ng·g -1 for sulfonamides and trimethoprim, respectively) were determined. Analyses of tilapia fillet samples from fish exposed to sulfamethazine through feed (incurred samples) were conducted in order to evaluate the method. This new method was demonstrated to be fast, sensitive, and suitable for monitoring sulfonamides and trimethoprim in tilapia fillet in health surveillance programs, as well as to be used in pharmacokinetics and residue depletion studies.
Nunes, Kátia S. D.; Assalin, Márcia R.; Vallim, José H.; Jonsson, Claudio M.; Queiroz, Sonia C. N.
2018-01-01
A multiresidue method for detecting and quantifying sulfonamides (sulfapyridine, sulfamerazine, sulfathiazole, sulfamethazine, sulfadimethoxine, sulfamethoxazole, and sulfamethoxypyridazine) and trimethoprim in tilapia fillet (Oreochromis niloticus) using liquid chromatography coupled to mass spectrometry was developed and validated. The sample preparation was optimized using the QuEChERS approach. The chromatographic separation was performed using a C18 column and 0.1% formic acid in water and acetonitrile as the mobile phase in the isocratic elution mode. Method validation was performed based on the Commission Decision 2002/657/EC and Brazilian guideline. The validation parameters evaluated were linearity (r ≥ 0.99); limits of detection (LOD) and quantification (LOQ), 1 ng·g−1 and 5 ng·g−1, respectively; intraday and interdays precision (CV lower than 19.4%). The decision limit (CCα 102.6–120.0 ng·g−1 and 70 ng·g−1 for sulfonamides and trimethoprim, respectively) and detection capability (CCβ 111.7–140.1 ng·g−1 and 89.9 ng·g−1 for sulfonamides and trimethoprim, respectively) were determined. Analyses of tilapia fillet samples from fish exposed to sulfamethazine through feed (incurred samples) were conducted in order to evaluate the method. This new method was demonstrated to be fast, sensitive, and suitable for monitoring sulfonamides and trimethoprim in tilapia fillet in health surveillance programs, as well as to be used in pharmacokinetics and residue depletion studies. PMID:29686929
El-Din, Mohie M K Sharaf; Attia, Khalid A M; Nassar, Mohamed W I; Kaddah, Mohamed M Y
2010-10-15
Two accurate, reliable, and highly sensitive spectrofluorimetric methods were developed for simultaneous determination of binary mixture gemfibrozil and rosiglitazone in human plasma without prior separation steps. The first method is based on synchronous fluorescence spectrometry using double scans. At Δλ=27nm, gemfibrozil yields detectable signal that is independent of the presence of rosiglitazone. Similarly, at Δλ=120nm the signal of rosiglitazone is not influenced by the presence of gemfibrozil. Signals at two wavelengths, 301 (Δλ=27nm) and 368nm (Δλ=120nm) vary linearly with gemfibrozil and rosiglitazone concentrations over the range 100-700ngmL(-1) (for gemfibrozil) and 20-140ngmL(-1) (for rosiglitazone), respectively. The limits of detection (LOD) were 2.3 and 2.72ngmL(-1) for gemfibrozil and rosiglitazone, respectively. The second method is based on the technique of simultaneous equations (Vierodt's method), in which 258nm was selected as the excitation wavelength. Two equations are constructed based on the fact that at ( λ(EM)₂=302 nm of gemfibrozil) and (λ(EM)₂=369 nm of rosiglitazone) the fluorescence of the mixture is the sum of the individual fluorescence of gemfibrozil and rosiglitazone. The limits of detection (LOD) were 28.1 and 23.63ngmL(-1) for gemfibrozil and rosiglitazone, respectively. The proposed methods were successfully applied for the determination of the two compounds in synthetic mixtures and in human plasma with a good recovery. Copyright © 2010 Elsevier B.V. All rights reserved.
Evaluation of two methods for direct detection of Fusarium spp. in water.
Graça, Mariana G; van der Heijden, Inneke M; Perdigão, Lauro; Taira, Cleison; Costa, Silvia F; Levin, Anna S
2016-04-01
Fusarium is a waterborne fungus that causes severe infections especially in patients with prolonged neutropenia. Traditionally, the detection of Fusarium in water is done by culturing which is difficult and time consuming. A faster method is necessary to prevent exposure of susceptible patients to contaminated water. The objective of this study was to develop a molecular technique for direct detection of Fusarium in water. A direct DNA extraction method from water was developed and coupled to a genus-specific PCR, to detect 3 species of Fusarium (verticillioides, oxysporum and solani). The detection limits were 10 cells/L and 1 cell/L for the molecular and culture methods, respectively. To our knowledge, this is the first method developed to detect Fusarium directly from water. Copyright © 2016 Elsevier B.V. All rights reserved.
Lomonaco, Tommaso; Ghimenti, Silvia; Piga, Isabella; Onor, Massimo; Melai, Bernardo; Fuoco, Roger; Di Francesco, Fabio
2013-11-01
Two analytical procedures are presented for the determination of the total content and unbound fraction of both warfarin and warfarin alcohols in human plasma. Chromatographic separation was carried out in isocratic conditions at 25°C on a C-18 reversed-phase column with a mobile phase consisting of a 70% buffer phosphate 25mM at pH=7, 25% methanol and 5% acetonitrile at a flow rate of 1.2mL/min. Fluorescence detection was performed at 390nm (excitation wavelength 310nm). Neither method showed any detectable interference or matrix effect. Inter-day recovery of the total warfarin and warfarin alcohols at a concentration level of 1000ng/mL was 89±3% and 73±3%, respectively, whereas for their unbound fraction (at a concentration level of 10ng/mL) was 66±8% and 90±7%, respectively. The intra- and inter-day precision (assessed as relative standard deviation) was <10% for both methods. The limits of detection were 0.4 and 0.2ng/mL for warfarin and warfarin alcohols, respectively. The methods were successfully applied to a pooled plasma sample obtained from 69 patients undergoing warfarin therapy. Copyright © 2013 Elsevier B.V. All rights reserved.
Nakamura, Shinichi; Tomita, Mamoru; Wada, Mitsuhiro; Chung, Heesun; Kuroda, Naotaka; Nakashima, Kenichiro
2006-01-01
A sensitive semi-micro column high-performance liquid chromatography with fluorescence detection method was developed for the determination of 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine (MP) and amphetamine (AP) in human hair. 4-(4,5-Diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) and 1-methyl-3-phenylpropylamine were used as labeling reagent and internal standard, respectively. These drugs were extracted from hair into 5% trifluoroacetic acid in methanol, and fluorescent labeled with DIB-Cl. The separation of DIB-derivatives was achieved on a reversed-phase semi-micro ODS column with an acetonitrile-methanol-water (30:40:30, v/v/v%) mixture as a mobile phase. The limits of detection at a signal-to-noise ratio of 3 for MDMA, MDA, MP and AP were 0.25, 0.15, 0.25 and 0.19 ng/mg, respectively. Precision of intra- and inter-day assay as the relative standard deviation were in the range 1.5-6.8% (n = 5) and 2.7-4.7% (n = 5), respectively. The proposed method was highly sensitive and able to detect MDMA and its related compounds in small amounts of hair sample, and could be applied to quantification of six abusers' hair samples. Copyright 2006 John Wiley & Sons, Ltd.
Zhang, Yang; Zhang, Meiqin; Wei, Qianhui; Gao, Yongjie; Guo, Lijuan; Al-Ghanim, Khalid A.; Mahboob, Shahid; Zhang, Xueji
2016-01-01
A simple electrochemical sensor has been developed for highly sensitive detection of octopamine and tyramine by electrodepositing reduced graphene oxide (ERGO) nanosheets onto the surface of a glassy carbon electrode (GCE). The electrocatalytic oxidation of octopamine and tyramine is individually investigated at the surface of the ERGO modified glassy carbon electrode (ERGO/GCE) by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Several essential factors including the deposition cycle of reduced graphene oxide nanosheets and the pH of the running buffer were investigated in order to determine the optimum conditions. Furthermore, the sensor was applied to the quantification of octopamine and tyramine by DPV in the concentration ranges from 0.5 to 40 μM and 0.1 to 25 μM, respectively. In addition, the limits of detection of octopamine and tyramine were calculated to be 0.1 μM and 0.03 μM (S/N = 3), respectively. The sensor showed good reproducibility, selectivity and stability. Finally, the sensor successfully detected octopamine and tyramine in commercially available beer with satisfactory recovery ranges which were 98.5%–104.7% and 102.2%–103.1%, respectively. These results indicate the ERGO/GCE based sensor is suitable for the detection of octopamine and tyramine. PMID:27089341
El-Maghrabey, Mahmoud H; Kishikawa, Naoya; Ohyama, Kaname; Kuroda, Naotaka
2014-11-01
A validated, simple and sensitive HPLC method was developed for the simultaneous determination of lipoperoxidation relevant reactive aldehydes: glyoxal (GO), acrolein (ACR), malondialdehyde (MDA), and 4-hydroxy-2-nonenal (HNE) in human serum. The studied aldehydes were reacted with 2,2'-furil to form fluorescent difurylimidazole derivatives that were separated on a C18 column using gradient elution and fluorescence detection at excitation and emission wavelengths of 250 and 355nm, respectively. The method showed good linearity over the concentration ranges of 0.100-5.00, 0.200-10.0, 0.200-40.0, and 0.400-10.0nmol/mL for GO, ACR, HNE, and MDA, respectively, with detection limits ranging from 0.030 to 0.11nmol/mL. The percentage RSD of intraday and interday precision did not exceed 5.0 and 6.2%, respectively, and the accuracy (%found) ranged from 95.5 to 103%. The proposed method was applied for monitoring the four aldehydes in sera of healthy, diabetic, and rheumatic human subjects with simple pretreatment steps and without interference from endogenous components. By virtue of its high sensitivity and accuracy, our method enabled detection of differences between analytes concentrations in sera of human subjects under different clinical conditions. Copyright © 2014 Elsevier Inc. All rights reserved.
Ruan, Jia; Ren, Dong-xia; Yang, Dan-ni; Long, Pin-pin; Zhao, Hong-yue; Wang, Yi-qi; Li, Yong-xin
2015-07-01
To establish a rapid and sensitive method based on polymerase chain reaction (PCR) combined with capillary electrophoresis-laser induced fluorescence (CE-LIF) and microchip capillary electrophoresis-laser induced fluorescence (MCE-LIF) for detecting adenoviruses in fecal samples. The DNA of adenovirus in fecal samples were extracted by the commercial kits and the conserved region of hexon gene was selected as the target gene and amplified by PCR reaction. After labeling highly sensitive nucleic acid fluorescent dye SYBR Gold and SYBR Orange respectively, PCR amplification products were separated by CE and MCE under the optimized condition and detected by LIF detector. PCR amplification products could be detected within 9 min by CE-LIF and 6 min by MCE-LIF under the optimized separation condition. The sequenced PCR product showed good specificity in comparison with the prototype sequences from NCBI. The intraday and inter-day relative standard deviation (RSD) of the size (bp) of the target DNA was in the range of 1.14%-1.34% and 1.27%- 2.76%, respectively, for CE-LIF, and 1.18%-1.48% and 2.85%-4.06%, respectively, for MCE-LIF. The detection limits was 2.33 x 10(2) copies/mL for CE-LIF and 2.33 x 10(3) copies/mL for MCE-LIF. The two proposed methods were applied to detect fecal samples, both showing high accuracy. The two proposed methods of PCR-CE-LIF and PCR-MCE-LIF can detect adenovirus in fecal samples rapidly, sensitively and specifically.
Cheng, Cheanyeh; Wu, Shing-Chen
2011-05-20
An innovative two-dimensional high-performance liquid chromatography system was developed for the simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero. A C8 reversed-phase chromatographic column with ultraviolet detection was used as the first dimension for the determination of aspartame, and a ligand-exchange chromatographic column with on-line postcolumn derivation fluorescence detection was employed as the second dimension for the analysis of amino acid enantiomers. The fluorimetric derivative reagent of amino acid enantiomers was o-phthaldialdehyde. The hydrolysis of aspartame in Coca-Cola Zero was induced by electric-heating or microwave heating. Aspartame was quantified by the matrix matched external standard calibration curve with a linear concentration range of 0-50 μg mL(-1) (r(2)=0.9984). The limit of detection (LOD) and the limit of quantification (LOQ) were 1.3 μg mL(-1) and 4.3 μg mL(-1), respectively. The amino acid enantiomers was analyzed by the matrix matched internal standard calibration method (D-leucine as the internal standard) with a linear concentration range of 0-10 μg mL(-1) (r(2)=0.9988-0.9997). The LODs and LOQs for L- and D-aspartic acid and L- and D-phenylalanine were 0.16-0.17 μg mL(-1) and 0.52-0.55 μg mL(-1), respectively, that was 12-13 times more sensitive than ultraviolet detection. The overall analysis accuracy for aspartame and amino acid enantiomers was 90.2-99.2% and 90.4-96.2%, respectively. The overall analysis precision for aspartame and amino acid enantiomers was 0.1-1.7% and 0.5-6.7%, respectively. Generally, the extent of aspartame hydrolysis increases with the increase of electro-thermal temperature, microwave power, and the duration of hydrolysis time. D-aspartic acid and D-phenylalanine can be observed with the electro-thermal racemization at the hydrolysis temperature 120°C for 1 day and only D-aspartic acid can be observed at the hydrolysis temperature 90°C for 2 and 3 days. For the microwave induced hydrolysis, only L-aspartic acid was detected at the power 560 W for 1 min and 320 W for 3 min. Copyright © 2011 Elsevier B.V. All rights reserved.
A Validation of Remotely Sensed Fires Using Ground Reports
NASA Astrophysics Data System (ADS)
Ruminski, M. G.; Hanna, J.
2007-12-01
A satellite based analysis of fire detections and smoke emissions for North America is produced daily by NOAA/NESDIS. The analysis incorporates data from the MODIS (Terra and Aqua) and AVHRR (NOAA-15/16/17) polar orbiting instruments and GOES East and West geostationary spacecraft with nominal resolutions of 1km and 4 km for the polar and geostationary platforms respectively. Automated fire detection algorithms are utilized for each of the sensors. Analysts perform a quality control procedure on the automated detects by deleting points that are deemed to be false detects and adding points that the algorithms did not detect. A limited validation of the final quality controlled product was performed using high resolution (30 m) ASTER data in the summer of 2006. Some limitations in using ASTER data are that each scene is only approximately 3600 square km, the data acquisition time is relatively constant at around 1030 local solar time and ASTER is another remotely sensed data source. This study expands on the ASTER validation by using ground reports of prescribed burns in Montana and Idaho for 2003 and 2004. It provides a non-remote sensing data source for comparison. While the ground data do not have the limitations noted above for ASTER there are still limitations. For example, even though the data set covers a much larger area (nearly 600,000 square km) than even several ASTER scenes, it still represents a single region of North America. And while the ground data are not restricted to a narrow time window, only a date is provided with each report, limiting the ability to make detailed conclusions about the detection capabilities for specific instruments, especially for the less temporally frequent polar orbiting MODIS and AVHRR sensors. Comparison of the ground data reports to the quality controlled fire analysis revealed a low rate of overall detection of 23.00% over the entire study period. Examination of the daily detection rates revealed a wide variation, with some days resulting in as little as 5 detects out of 107 reported fires while other days had as many as 84 detections out of 160 reports. Inspection of the satellite imagery from the days with very low detection rates revealed that extensive cloud cover prohibited satellite fire detection. On days when cloud cover was at a minimum, detection rates were substantially higher. An estimate of the fire size was also provided with the ground data set. Statistics will be presented for days with minimal cloud cover which will indicate the probability of detection for fires of various sizes.
Han, Dan; Wei, Chunying
2018-05-01
In this work, we develop a fluorescent molecular beacon based on the DNA-templated silver nanoclusters (DNA-Ag NCs). The skillfully designed molecular beacon can be conveniently used for detection of diverse virulence genes as long as the corresponding recognition sequences are embedded. Importantly, the constructed detection system allows simultaneous detection of multiple nucleic acids, which is attributed to non-overlapping emission spectra of the as-synthesized silver nanoclusters. Based on the target-induced fluorescence enhancement, three infectious disease-related genes HIV, H1N1, and H5N1 are detected, and the corresponding detection limits are 3.53, 0.12 and 3.95nM, respectively. This design allows specific, versatile and simultaneous detection of diverse targets with easy operation and low cost. Copyright © 2017 Elsevier B.V. All rights reserved.
Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin
2017-12-01
A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chivarzin, M E; Revelsky, I A; Nikoshina, A V; Buldyzkova, A N; Chepeliansky, D A; Revelsky, A I; Buriak, A K
2016-04-01
The fast method of the simultaneous determination of F(-), Cl(-), Br(-) and SO4(2-) anions in the deionized water on the trace level by ion chromatography using thorough cleaning of respective water containers, 10 μM NaHCO3 water solution as eluent, short Metrohm (50 × 4 mm) separation column and a large water volume injection is proposed. Calculated detection limits are 10(-9)-10(-8)% depending on the element. The method for the fast screening of plant oil samples for the total fluorine-, chlorine-, bromine- and sulfur-organic compounds content (calculated for the respective elements) on the trace level is developed. It is based on the high temperature combustion of oil sample in oxygen flow, absorption of the conversion products in deionized water and whole absorbate volume analysis for F(-), Cl(-), Br(-) and SO4(2-) anions, corresponding to the respective elements, using the developed method of these anions analysis by ion chromatography. The samples of soya, olive, sunflower and cotton seed oil were analyzed. The method detection limits (for 1mg sample) were 2 × 10(-6)%, 2 × 10(-6)%, 5 × 10(-6)% and 5 × 10(-6)% for fluorine, chlorine, bromine and sulfur, respectively. The relative standard deviation was ≤ 15%. The method gives the compressed information about the total content of all target and nontarget fluorine-, chlorine-, bromine- and sulfur-organic compounds in plant oils. Copyright © 2015. Published by Elsevier B.V.
Photoacoustic Effect of Ethene: Sound Generation due to Plant Hormone Gases.
NASA Astrophysics Data System (ADS)
Park, Han Jung; Ide, David; University of Tennessee at Chattanooga Team
2017-01-01
Ethene, which is produced in plants as they mature, was used to study its photoacoustic properties using photoacoustic spectroscopy. Detection of trace amounts, with N2 gas, of the ethylene gas were also applied. The gas was tested in various conditions: temperature, concentration of the gas, gas cell length, and power of the laser, were varied to determine their effect on the photoacoustic signal, the ideal conditions to detect trace gas amounts, and concentration of ethylene produced by an avocado and banana. A detection limit of 10 ppm was determined for pure C2H4. A detection of 5% and 13% (by volume) concentration of ethylene were produced for a ripening avocado and banana, respectively, in closed space.
Kneisel, Stefan; Speck, Michael; Moosmann, Bjoern; Corneillie, Todd M; Butlin, Nathaniel G; Auwärter, Volker
2013-05-01
Serum and urine samples are commonly used for the analysis of synthetic cannabinoids in biofluids; however, their utilization as analytical matrices for drug abstinence control features some substantial drawbacks. While for blood collection invasive sampling is inevitable, the urinary analysis of synthetic cannabinoids is limited by the lack of available reference standards of the respective major metabolites. Moreover, the long detectability of synthetic cannabinoids in both matrices hampers the identification of a recent synthetic cannabinoid use. This article describes the development, validation and application of an LC/ESI-MS/MS method for the quantification of 28 synthetic cannabinoids in neat oral fluid (OF) samples. OF samples were prepared by protein precipitation using ice-cold acetonitrile. Chromatographic separation was achieved by gradient elution on a Luna Phenyl Hexyl column (50 × 2 mm, 5 μm), while detection was carried out on a QTrap 4000 instrument in positive ionization mode. The limits of detection ranged from 0.02 to 0.40 ng/mL, whereas the lower limits of quantification ranged from 0.2 to 4.0 ng/mL. The method was applied to authentic samples collected during two preliminary studies in order to obtain insights into the general detectability and detection windows of synthetic cannabinoids in this matrix. The results indicate that synthetic cannabinoids are transferred from the blood stream into OF and vice versa only at a very low rate. Therefore, positive OF samples are due to contamination of the oral cavity during smoking. As these drug-contaminations could be detected up to approximately 2 days, neat oral fluid appears to be well suited for detection of a recent synthetic cannabinoid use.
Ichibangase, T; Ohba, Y; Kishikawa, N; Nakashima, K; Kuroda, N
2014-03-01
8-Amino-5-chloro-7-phenylpyrido[3,4-d]pyridazine-1,4(2H,3H)dione (L-012) was recently synthesized as a new chemiluminescence (CL) probe; the light intensity and the sensitivity of L-012 are higher than those of other CL probes such as luminol. Previously, our group developed four lophine-based CL enhancers of the horseradish peroxidase (HRP)-catalyzed CL oxidation of luminol, namely 2-(4-hydroxyphenyl)-4,5-diphenylimidazole (HDI), 2-(4-hydroxyphenyl)-4,5-di(2-pyridyl)imidazole (HPI), 4-(4,5-diphenyl-1H-imidazol-2-yl)phenylboronic acid (DPA), and 4-[4,5-di(2-pyridyl)-1H-imidazol-2-yl]phenylboronic acid (DPPA), and showed that DPPA was suitable for the photographic detection of HRP. In this study, we replaced luminol with L-012 and evaluated these as L-012-dependent CL enhancers. In addition, to detect HRP and/or H2O2 with higher sensitivity, each detection condition for the L-012-HRP-H2O2 enhanced CL was optimized. All the derivatives enhanced the L-012-dependent CL as well as luminol CL; HPI generated the highest enhanced luminescence. Under optimized conditions for HRP detection, the detection limit of HRP was 0.08 fmol. By contrast, the detection limit of HRP with the enhanced L-012-dependent CL using 4-iodophenol, which is a common enhancer of luminol CL, was 1.1 fmol. With regard to H2O2 detection, the detection limits for enhanced CL with HPI and 4-iodophenol were 0.29 and 1.5 pmol, respectively. Therefore, it is demonstrated that HPI is the most superior L-012-dependent CL enhancer. Copyright © 2013 John Wiley & Sons, Ltd.
Analysis of sesquiterpenes in Valeriana officinalis by capillary electrophoresis.
Mikell, J R; Ganzera, M; Khan, I A
2001-12-01
A capillary electrophoresis (CE) method permitting the determination of the main sesquiterpenes in Valeriana officinalis has been developed. A separation of valerenic acid and its hydroxy and acetoxy derivatives, three compounds characteristic for the species, was achieved using a 40 mM phosphate-borate buffer at pH 8.5, which contained 10% isopropanol as organic modifier. Applied temperature and voltage were 35 degrees C and 17.5 kV, respectively. This setup allowed a baseline separation of the three compounds within 8 min, with a detection limit of 5.8 micrograms/ml or less. Out of six market products analyzed, only one contained a detectable amount of the marker compounds, with 0.54% of hydroxyvalerenic acid and 0.13% valerenic acid, respectively. The quantitative results were comparable to those obtained by HPLC.
Karlowatz, M; Kraft, M; Mizaikoff, B
2004-05-01
Attenuated total reflection mid-infrared spectroscopy is applied for simultaneous detection and quantification of the environmentally relevant analytes benzene, toluene, and the three xylene isomers. The analytes are enriched into a thin polymer membrane coated onto the surface of an internal reflection waveguide, which is exposed to the aqueous sample. Direct detection of analytes permeating into the polymer coating is performed by utilizing evanescent field spectroscopy in the fingerprint range (>10 microm) of the mid-infrared (MIR) spectrum (3-20 microm) without additional sample preparation. All investigated compounds are characterized by well-separated absorption features in the evaluated wavelength regime. Hence, data evaluation was performed by integration of the respective absorption peaks. Limits of detection lower than 20 ppb (v/v) for all xylene isomers, 45 ppb (v/v) for benzene, and 80 ppb (v/v) for toluene have been achieved. The straightforward experimental setup and the achieved detection limits for these environmentally relevant volatile organic compounds in the low-ppb concentration range reveal a substantial potential of MIR evanescent field sensing devices for on-line in situ environmental analysis.
Development of a one-step immunochromatographic strip test for the detection of sennosides A and B.
Putalun, Waraporn; Morinaga, Osamu; Tanaka, Hiroyuki; Shoyama, Yukihiro
2004-01-01
An immunochromatographic strip test was developed to detect sennoside A (1) and sennoside B (2) using anti-1 and anti-2 monoclonal antibodies. The qualitative assay was based on a competitive immunoassay in which the detector reagent consisted of colloidal gold particles coated with the respective sennoside antibodies. The capture reagents were 1- and 2-human serum albumin (HSA) conjugates immobilised on a nitrocellulose membrane on the test strip. The sample containing 1 and 2, together with detector reagent, passed over the zone where the capture reagents had been immobilised. The analytes in the sample competed for binding to the limited amount of antibodies in the detector reagent with the immobilised 1- and 2-HSA conjugates on the membrane and hence positive samples showed no colour in the capture spot zone. Detection limits for the strip test were 125 ng/mL for both sennosides. The assay system is useful as a rapid and simple screening method for the detection of 1 and 2 in plants, drugs and body fluids.
Applications of small surface plasmon resonance sensors for biochemical monitoring
NASA Astrophysics Data System (ADS)
Masson, Jean-Francois; Battaglia, Tina M.; Beaudoin, Stephen; Booksh, Karl S.
2004-12-01
The development of small surface plasmon resonance (SPR) sensors to detect biological markers for myocardial ischemia (MI), spinal muscular atrophy (SMA), and wound healing was achieved at low ng/mL and in less than 10 minutes. The markers of interest for MIs are myoglobin (MG) and cardiac Troponin I (cTnI). The limits of detection for these markers are respectively 600 pg/mL and 1.4 ng/mL in saline solution. To study SMA, the level of survival motor neuron protein (SMN) was investigated. A limit of detection of 990 pg/mL was achieved for the detection of SMN. The interactions of SMN with MG decreased the signal for both SMN and MG. Interleukin 6 and tumor necrosis factor alpha (TNFa) were investigated to monitor wound healing. The sensor's performance in more complex solutions, e.g.: serum, showed a large non-specific signal. Modifying the support on which the antibodies are attached improved the sensor's stability in serum by a factor of 5. To achieve this non-specific binding (NSB) reduction, different polysaccharides, biocompatible polymers and short chain thiols were investigated.
Swider, Catherine; Maguire, Kelly; Rickenbach, Michael; Montgomery, Madeline; Ducote, Matthew J; Marhefka, Craig A
2012-07-01
Following the September 11, 2001 terrorist attacks, letters containing Bacillus anthracis were distributed through the United States postal system killing five people. A complex forensic investigation commenced to identify the perpetrator of these mailings. A novel liquid chromatography/mass spectrometry protocol for the qualitative detection of trace levels of meglumine and diatrizoate in dried spore preparations of B. anthracis was developed. Meglumine and diatrizoate are components of radiographic imaging products that have been used to purify bacterial spores. Two separate chromatographic assays using multiple mass spectrometric analyses were developed for the detection of meglumine and diatrizoate. The assays achieved limits of detection for meglumine and diatrizoate of 1.00 and 10.0 ng/mL, respectively. Bacillus cereus T strain spores were effectively used as a surrogate for B. anthracis spores during method development and validation. This protocol was successfully applied to limited evidentiary B. anthracis spore material, providing probative information to the investigators. 2012 American Academy of Forensic Sciences. Published 2012. This article is a U.S. Government work and is in the public domain in the U.S.A.
Nissen, Mona; Doherty, Brenda; Hamperl, Jonas; Kobelke, Jens; Weber, Karina; Henkel, Thomas; Schmidt, Markus A
2018-02-06
Due to a worldwide increased use of pharmaceuticals and, in particular, antibiotics, a growing number of these substance residues now contaminate natural water resources and drinking supplies. This triggers a considerable demand for low-cost, high-sensitivity methods for monitoring water quality. Since many biological substances exhibit strong and characteristic absorption features at wavelengths shorter than 300 nm, UV spectroscopy presents a suitable approach for the quantitative identification of such water-contaminating species. However, current UV spectroscopic devices often show limited light-matter interaction lengths, demand sophisticated and bulky experimental infrastructure which is not compatible with microfluidics, and leave large fractions of the sample analyte unused. Here, we introduce the concept of UV spectroscopy in liquid-filled anti-resonant hollow core fibers, with large core diameters and lengths of approximately 1 m, as a means to overcome such limitations. This extended light-matter interaction length principally improves the concentration detection limit by two orders of magnitude while using almost the entire sample volume-that is three orders of magnitude smaller compared to cuvette based approaches. By integrating the fibers into an optofluidic chip environment and operating within the lowest experimentally feasible transmission band, concentrations of the application-relevant pharmaceutical substances, sulfamethoxazole (SMX) and sodium salicylate (SS), were detectable down to 0.1 µM (26 ppb) and 0.4 µM (64 ppb), respectively, with the potential to reach significantly lower detection limits for further device integration.
Nissen, Mona; Doherty, Brenda; Hamperl, Jonas; Kobelke, Jens; Weber, Karina; Henkel, Thomas; Schmidt, Markus A.
2018-01-01
Due to a worldwide increased use of pharmaceuticals and, in particular, antibiotics, a growing number of these substance residues now contaminate natural water resources and drinking supplies. This triggers a considerable demand for low-cost, high-sensitivity methods for monitoring water quality. Since many biological substances exhibit strong and characteristic absorption features at wavelengths shorter than 300 nm, UV spectroscopy presents a suitable approach for the quantitative identification of such water-contaminating species. However, current UV spectroscopic devices often show limited light-matter interaction lengths, demand sophisticated and bulky experimental infrastructure which is not compatible with microfluidics, and leave large fractions of the sample analyte unused. Here, we introduce the concept of UV spectroscopy in liquid-filled anti-resonant hollow core fibers, with large core diameters and lengths of approximately 1 m, as a means to overcome such limitations. This extended light-matter interaction length principally improves the concentration detection limit by two orders of magnitude while using almost the entire sample volume—that is three orders of magnitude smaller compared to cuvette based approaches. By integrating the fibers into an optofluidic chip environment and operating within the lowest experimentally feasible transmission band, concentrations of the application-relevant pharmaceutical substances, sulfamethoxazole (SMX) and sodium salicylate (SS), were detectable down to 0.1 µM (26 ppb) and 0.4 µM (64 ppb), respectively, with the potential to reach significantly lower detection limits for further device integration. PMID:29415468
Lawryk, Nicholas J; Feng, H Amy; Chen, Bean T
2009-07-01
Recent advances in field-portable X-ray fluorescence (FP XRF) spectrometer technology have made it a potentially valuable screening tool for the industrial hygienist to estimate worker exposures to airborne metals. Although recent studies have shown that FP XRF technology may be better suited for qualitative or semiquantitative analysis of airborne lead in the workplace, these studies have not extensively addressed its ability to measure other elements. This study involved a laboratory-based evaluation of a representative model FP XRF spectrometer to measure elements commonly encountered in workplace settings that may be collected on air sample filter media, including chromium, copper, iron, manganese, nickel, lead, and zinc. The evaluation included assessments of (1) response intensity with respect to location on the probe window, (2) limits of detection for five different filter media, (3) limits of detection as a function of analysis time, and (4) bias, precision, and accuracy estimates. Teflon, polyvinyl chloride, polypropylene, and mixed cellulose ester filter media all had similarly low limits of detection for the set of elements examined. Limits of detection, bias, and precision generally improved with increasing analysis time. Bias, precision, and accuracy estimates generally improved with increasing element concentration. Accuracy estimates met the National Institute for Occupational Safety and Health criterion for nearly all the element and concentration combinations. Based on these results, FP XRF spectrometry shows potential to be useful in the assessment of worker inhalation exposures to other metals in addition to lead.
Detection limit for rate fluctuations in inhomogeneous Poisson processes
NASA Astrophysics Data System (ADS)
Shintani, Toshiaki; Shinomoto, Shigeru
2012-04-01
Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.
Detection limit for rate fluctuations in inhomogeneous Poisson processes.
Shintani, Toshiaki; Shinomoto, Shigeru
2012-04-01
Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.
Paleologos, E K; Kontominas, M G
2005-06-10
A method using normal phase high performance liquid chromatography (NP-HPLC) with UV detection was developed for the analysis of acrylamide and methacrylamide. The method relies on the chromatographic separation of these analytes on a polar HPLC column designed for the separation of organic acids. Identification of acrylamide and methacrylamide is approached dually, that is directly in their protonated forms and as their hydrolysis products acrylic and methacrylic acid respectively, for confirmation. Detection and quantification is performed at 200 nm. The method is simple allowing for clear resolution of the target peaks from any interfering substances. Detection limits of 10 microg L(-1) were obtained for both analytes with the inter- and intra-day RSD for standard analysis lying below 1.0%. Use of acetonitrile in the elution solvent lowers detection limits and retention times, without impairing resolution of peaks. The method was applied for the determination of acrylamide and methacrylamide in spiked food samples without native acrylamide yielding recoveries between 95 and 103%. Finally, commercial samples of french and roasted fries, cookies, cocoa and coffee were analyzed to assess applicability of the method towards acrylamide, giving results similar with those reported in the literature.
Yuan, Yahong; Liu, Bin; Wang, Ling; Yue, Tianli
2015-01-01
An approach based on immunomagnetic separation (IMS) and SYBR Green I real-time PCR (real-time PCR) with species-specific primers and melting curve analysis was proposed as a rapid and effective method for detecting Alicyclobacillus spp. in fruit juices. Specific primers targeting the 16S rDNA sequences of Alicyclobacillus spp. were designed and then confirmed by the amplification of DNA extracted from standard strains and isolates. Spiked samples containing known amounts of target bacteria were used to obtain standard curves; the correlation coefficient was greater than 0.986 and the real-time PCR amplification efficiencies were 98.9%- 101.8%. The detection limit of the testing system was 2.8×101 CFU/mL. The coefficient of variation for intra-assay and inter-assay variability were all within the acceptable limit of 5%. Besides, the performance of the IMS-real-time PCR assay was further investigated by detecting naturally contaminated kiwi fruit juice; the sensitivity, specificity and accuracy were 91.7%, 95.9% and 95.3%, respectively. The established IMS-real-time PCR procedure provides a new method for identification and quantitative detection of Alicyclobacillus spp. in fruit juice. PMID:26488469
Do manatees utilize infrasonic communication or detection?
NASA Astrophysics Data System (ADS)
Gerstein, Edmund; Gerstein, Laura; Forsythe, Steve; Blue, Joseph
2004-05-01
Some researchers speculate Sirenians might utilize infrasonic communication like their distant elephant cousins; however, audiogram measurements and calibrated manatee vocalizations do not support this contention. A comprehensive series of hearing tests conducted with West Indian manatees yielded the first and most definitive audiogram for any Sirenian. The manatee hearing tests were also the first controlled underwater infrasonic psychometric tests with any marine mammal. Auditory thresholds were measured from 0.4 to 46 kHz, but detection thresholds of possible vibrotactile origin were measured as low as 0.015 kHz. Manatees have short hairs on their bodies that may be sensitive vibrotactile receptors capable of detecting particle displacement in the near field. To detect these signals the manatee rotated on axis, exposing the densest portion of hairs toward the projector. Manatees inhabit shallow water where particle motion detection may be more useful near the water's surface, where sound pressures are low due to the Lloyd mirror effect. With respect to intraspecific communication, no infrasonic spectra have been identified in hundreds of calibrated calls. Low source levels and propagation limits in shallow-water habitats suggest low-frequency manatee calls have limited utility over long distances and infrasonic communication is not an attribute shared with elephants.
Yang, Yang; Qin, Xiaodong; Zhang, Wei; Li, Yanmin; Zhang, Zhidong
2016-10-01
Porcine parvovirus (PPV) is a major cause of swine reproductive failure and reported in many countries worldwide. Recombinase polymerase amplification (RPA) assays using a real-time fluorescent detection (PPV real-time RPA assay) and a lateral flow dipstick (PPV RPA LFD assay) were developed targeting PPV NS1 gene. The detection limit of PPV real-time RPA assay was 300 copies per reaction within 9 min at 38 °C, while the RPA LFD assay has a detection limit of 400 copies per reaction in less than 20 min at 38 °C. In both assays, there were no cross-reactions with porcine circovirus type 2, pseudorabies virus, porcine reproductive and respiratory syndrome virus, classical swine fever virus, and foot-and-mouth disease virus. Based on a total of 128 clinical samples examined, the sensitivity and the specificity of the developed RPA assays for identification of PPV was 94.4% and 100%, respectively, when compared to real-time (qPCR) assay. Therefore, the RPA assay provides a rapid, sensitive and specific alternative for PPV detection. Copyright © 2016 Elsevier Ltd. All rights reserved.
Miyake, Mayo; Nakajima, Hizuru; Hemmi, Akihide; Yahiro, Masayuki; Adachi, Chihaya; Soh, Nobuaki; Ishimatsu, Ryoichi; Nakano, Koji; Uchiyama, Katsumi; Imato, Toshihiko
2012-07-15
The performance of an organic thin film photodiode (OPD), fabricated from a hetero-junction comprised of two layers of C(60) and a phthalocyanine-Cu(II) complex was evaluated by detecting the chemiluminescence generated from the reaction of luminol with horseradish peroxidase in the presence of H(2)O(2), and the fluorescence from resorufin, as an optical detector. The photocurrent of the OPD was linear with respect to the power of light from a commercial LED. The sensitivity of the OPD was sufficient for detecting chemiluminescence with a power 0.1μW/cm(2). The OPD was successfully used in a flow-immunoassay for IgA, a marker of human stress, in which a sandwich immunoassay was carried out on the microchip and the fluorescence from resorufin, produced by the enzymatic reaction, was detected. The detection limits for resorufin and IgA were 5.0μM and 16ng/mL, respectively. The photosensitivity of the OPD remained relatively constant for a minimum of one year. Copyright © 2012 Elsevier B.V. All rights reserved.
Muñoz, Constanza; Zumarán, Cecilia; González, Tamara; Wozniak, Aniela; Castillo, Claudia; García, Patricia
2017-08-01
The detection of carbapenemase-producing gram negative bacilli is complicated, because there are available multiple options of test. The confirmation of the enzyme by molecular characterization is not available in all laboratories in our country. To propose a fast, efficient and simple strategy to detect and confirm CPB. 39 CPB isolates and 8 non-producing were used to evaluate the phenotypic test Carba NP, CarbAcineto NP and Blue-Carba, validating the test Xpert® Carba-R, to be used directly with bacterial colonies with conventional PCR. The sensitivity of Carba NP, CarbAcineto NP and Blue-Carba was 79,5; 87,2 y 84,6%, respectively; and specificity was 79.5; 87.2 and 84.6%, respectively. The limit of detection of Xpert® Carba-R was different for each carbapenemasa: 40.8 ufc/reaction to KPC and NDM and 30.6 ufc/reaction to VIM. On isolates with decreased susceptibility to carbapenems we propose to use as screening the test CarbAcineto NP, follow by Xpert®Carba-R to characterize the carbapenemase and adopt specific infection control measures.
Wei, Wei; Yu, Xiaodong; Ju, Huangxin
2004-03-01
The binding constants of beta-cyclodextrin (beta-CD) with antalgic drugs such as naproxen, ketoprofen, ibuprofen, acemetacin, and aspirin are determined by affinity capillary electrophoresis. Based on these interactions, a reliable method for the separation and simultaneous determinations of these compounds in the presence of 5.0 mM beta-CD in phosphate buffer solution is presented by capillary zone electrophoresis with UV detection at 214 nm for naproxen and 200 nm for the others. The linear ranges for naproxen, ketoprofen, ibuprofen, acemetacin, aspirin, and caffeine detections are from 2.0 to 800, 2.5 to 1000, 2.5 to 700, 2.5 to 700, 2.0 to 800, and 1.5 to 800 microg/mL, respectively. Their detection limits are 1.0, 0.5, 0.5, 1.5, 1.5, and 1.0 microg/mL at a signal to noise ratio of 3, respectively. This method has been successfully applied to the detections of these drugs in the pharmaceutical formulations (tablets or capsules) and urine samples.
Clancy, Eoin; Coughlan, Helena; Higgins, Owen; Boo, Teck Wee; Cormican, Martin; Barrett, Louise; Smith, Terry J; Reddington, Kate; Barry, Thomas
2016-08-01
Three duplex molecular beacon based real-time Nucleic Acid Sequence Based Amplification (NASBA) assays have been designed and experimentally validated targeting RNA transcripts for the detection and identification of Haemophilus influenzae, Neisseria meningitidis and Streptococcus pneumoniae respectively. Each real-time NASBA diagnostics assay includes an endogenous non-competitive Internal Amplification Control (IAC) to amplify the splice variant 1 mRNA of the Homo sapiens TBP gene from human total RNA. All three duplex real-time NASBA diagnostics assays were determined to be 100% specific for the target species tested for. Also the Limits of Detection (LODs) for the H. influenzae, N. meningitidis and S. pneumoniae duplex real-time NASBA assays were 55.36, 0.99, and 57.24 Cell Equivalents (CE) respectively. These robust duplex real-time NASBA diagnostics assays have the potential to be used in a clinical setting for the rapid (<60min) specific detection and identification of the most prominent microorganisms associated with bacterial meningitis in humans. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Xiaoting; Chen, Beibei; He, Man; Wang, Han; Xiao, Guangyang; Yang, Bin; Hu, Bin
2017-04-15
In this work, we demonstrate a novel method based on inductively coupled plasma mass spectrometry (ICP-MS) detection with gold nanoparticles (Au NPs) and quantum dots (QDs) labeling for the simultaneous counting of two circulating tumor cell lines (MCF-7 and HepG2 cells) in human blood. MCF-7 and HepG2 cells were captured by magnetic beads coupled with anti-EpCAM and then specifically labeled by CdSe QDs-anti-ASGPR and Au NPs-anti-MUC1, respectively, which were used as signal probes for ICP-MS measurement. Under the optimal experimental conditions, the limits of detection of 50 MCF-7, 89 HepG2 cells and the linear ranges of 200-40000 MCF-7, 300-30000 HepG2 cells were obtained, and the relative standard deviations for seven replicate detections of 800 MCF-7 and HepG2 cells were 4.6% and 5.7%, respectively. This method has the advantages of high sensitivity, low sample consumption, wide linear range and can be extended to the simultaneous detection of multiple CTC lines in human peripheral blood. Copyright © 2016 Elsevier B.V. All rights reserved.
Marois-Créhan, Corinne; Lacouture, Sonia; Jacques, Mario; Fittipaldi, Nahuel; Kobisch, Marylène; Gottschalk, Marcelo
2014-01-01
Two real-time, or quantitative, polymerase chain reaction (qPCR) assays were developed to detect Actinobacillus pleuropneumoniae serovars 1-9-11 (highly related serovars with similar virulence potential) and serovar 2, respectively. The specificity of these assays was verified on a collection of 294 strains, which included all 16 reference A. pleuropneumoniae strains (including serovars 5a and 5b), 263 A. pleuropneumoniae field strains isolated between 1992 and 2009 in different countries, and 15 bacterial strains other than A. pleuropneumoniae. The detection levels of both qPCR tests were evaluated using 10-fold dilutions of chromosomal DNA from reference strains of A. pleuropneumoniae serovars 1 and 2, and the detection limit for both assays was 50 fg per assay. The analytical sensitivities of the qPCR tests were also estimated by using pure cultures and tonsils experimentally spiked with A. pleuropneumoniae. The detection threshold was 2.5 × 10(4) colony forming units (CFU)/ml and 2.9 × 10(5) CFU/0.1 g of tonsil, respectively, for both assays. These specific and sensitive tests can be used for the serotyping of A. pleuropneumoniae in diagnostic laboratories to control porcine pleuropneumonia.
Li, Cui; Zhang, Yaoyao; Eremin, Sergei A; Yakup, Omar; Yao, Gang; Zhang, Xiaoying
2017-07-15
Our aim in this study is to show that IgY antibody based immunoassays could be used to detect antibiotic residues in animal-derived food. Briefly, full antigens of gentamicin (Gent) and kanamycin (Kana) were used to immunize the laying chickens to prepare IgY antibodies. Then, these antibodies were evaluated by FPIA and ic-ELISA to detect Gent/Kana in animal-derived samples. The IC 50 of FPIA and ic-ELISA based anti-Gent IgY were 7.70±0.6μg/mL and 0.32±0.06μg/mL, respectively. The IC 50 of FPIA and ic-ELISA based anti-Kana IgY were 7.97±0.9μg/mL and 0.15±0.01μg/mL. The limits of detection (LOD, IC 10 ) for FPIA based anti-Gent/Kana IgY were 0.17 and 0.007μg/mL, respectively. The LOD for ic-ELISA were both 0.001μg/mL. These results indicated that the ic-ELISA might more suitable for antibiotic residues detection than FPIA. Copyright © 2017 Elsevier Ltd. All rights reserved.
Real-time traffic sign detection and recognition
NASA Astrophysics Data System (ADS)
Herbschleb, Ernst; de With, Peter H. N.
2009-01-01
The continuous growth of imaging databases increasingly requires analysis tools for extraction of features. In this paper, a new architecture for the detection of traffic signs is proposed. The architecture is designed to process a large database with tens of millions of images with a resolution up to 4,800x2,400 pixels. Because of the size of the database, a high reliability as well as a high throughput is required. The novel architecture consists of a three-stage algorithm with multiple steps per stage, combining both color and specific spatial information. The first stage contains an area-limitation step which is performance critical in both the detection rate as the overall processing time. The second stage locates suggestions for traffic signs using recently published feature processing. The third stage contains a validation step to enhance reliability of the algorithm. During this stage, the traffic signs are recognized. Experiments show a convincing detection rate of 99%. With respect to computational speed, the throughput for line-of-sight images of 800×600 pixels is 35 Hz and for panorama images it is 4 Hz. Our novel architecture outperforms existing algorithms, with respect to both detection rate and throughput
Jain, Neha; Merwyn, S; Rai, G P; Agarwal, G S
2012-05-01
Real-time polymerase chain reaction (real-time PCR) is a laboratory technique based on PCR. This technique is able to detect sequence-specific PCR products as they accumulate in "real time" during the PCR amplification, and also to quantify the number of substrates present in the initial PCR mixture before amplification begins. In the present study, real-time PCR assay was employed for rapid and real-time detection of Bacillus anthracis spores spiked in 0.1 g of soil and talcum powder ranging from 5 to 10(7) spores. DNA was isolated from spiked soil and talcum powder, using PBS containing 1 % Triton-X-100, followed by heat treatment. The isolated DNA was used as template for real-time PCR and PCR. Real-time PCR amplification was obtained in 60 min under the annealing condition at 60°C by employing primers targeting the pag gene of B. anthracis. In the present study, the detection limit of real-time PCR assay in soil was 10(3) spores and 10(2) spores in talcum powder, respectively, whereas PCR could detect 10(4) spores in soil and 10(3) spores in talcum powder, respectively.
Zhang, Yuanyuan; Jiang, Hui; Wang, Xuemei
2015-04-22
In this study, we have developed a label-free, dual functional detection strategy for highly selective and sensitive determination of aqueous Ag(+) and Hg(2+) by using cytidine stabilized Au NCs and AuAg NCs as fluorescent turn-on and turn off probes, respectively. The Au NCs and AuAg NCs showed a remarkably rapid response and high selectivity for Ag(+) and Hg(2+) over other metal ions, and relevant detection limit of Ag(+) and Hg(2+) is ca. 10 nM and 30 nM, respectively. Importantly, the fluorescence enhanced Au NCs by doping Ag(+) can be conveniently reusable for the detection of Hg(2+) based on the corresponding fluorescence quenching. The sensing mechanism was based on the high-affinity metallophilic Hg(2+)-Ag(+) interaction, which effectively quenched the fluorescence of AuAg NCs. Furthermore, these fluorescent nanoprobes could be readily applied to Ag(+) and Hg(2+) detection in environmental water samples, indicating their possibility to be utilized as a convenient, dual functional, rapid response, and label-free fluorescence sensor for related environmental and health monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.
Du, Xin-Jun; Zhou, Tian-Jiao; Li, Ping; Wang, Shuo
2017-08-01
Salmonella is a major foodborne pathogen that is widespread in the environment and can cause serious human and animal disease. Since conventional culture methods to detect Salmonella are time-consuming and laborious, rapid and accurate techniques to detect this pathogen are critically important for food safety and diagnosing foodborne illness. In this study, we developed a rapid, simple and portable Salmonella detection strategy that combines thermophilic helicase-dependent amplification (tHDA) with a lateral flow assay to provide a detection result based on visual signals within 90 min. Performance analyses indicated that the method had detection limits for DNA and pure cultured bacteria of 73.4-80.7 fg and 35-40 CFU, respectively. Specificity analyses showed no cross reactions with Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, Enterobacter aerogenes, Shigella and Campylobacter jejuni. The results for detection in real food samples showed that 1.3-1.9 CFU/g or 1.3-1.9 CFU/mL of Salmonella in contaminated chicken products and infant nutritional cereal could be detected after 2 h of enrichment. The same amount of Salmonella in contaminated milk could be detected after 4 h of enrichment. This tHDA-strip can be used for the rapid detection of Salmonella in food samples and is particularly suitable for use in areas with limited equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Indrasena, W M; Ackman, R G; Gill, T A
1999-09-10
Thin-layer chromatography (TLC) on Chromarods-SIII with the Iatroscan (Mark-5) and a flame thermionic detector (FTID) was used to develop a rapid method for the detection of paralytic shellfish poisoning (PSP) toxins. The effect of variation in hydrogen (H2) flow, air flow, scan time and detector current on the FTID peak response for both phosphatidylcholine (PC) and PSP were studied in order to define optimum detection conditions. A combination of hydrogen and air flow-rates of 50 ml/min and 1.5-2.0 l/min respectively, along with a scan time of 40 s/rod and detector current of 3.0 A (ampere) or above were found to yield the best results for the detection of PSP compounds. Increasing the detector current level to as high as 3.3 A gave about 130 times more FTID response than did flame ionization detection (FID), for PSP components. Quantities of standards as small as 1 ng neosaxitoxin (NEO), 5 ng saxitoxin (STX), 5 ng B1-toxins (B1), 2 ng gonyautoxin (GTX) 2/3, 6 ng GTX 1/4 and 6 ng C-toxins (C1/C2) could be detected with the FTID. The method detection limits for toxic shellfish tissues using the FTID were 0.4, 2.1, 0.8 and 2.5 micrograms per g tissue for GTX 2/3, STX, NEO and C toxins, respectively. The FTID response increased with increasing detector current and with increasing the scan time. Increasing hydrogen and air flow-rates resulted in decreasing sensitivity within defined limits. Numerous solvent systems were tested, and, solvent consisting of chloroform: methanol-water-acetic acid (30:50:8:2) could separate C toxins from GTX, which eluted ahead of NEO and STX. Accordingly, TLC/FTID with the Iatroscan (Mark-5) seems to be a promising, relatively inexpensive and rapid method of screening plant and animal tissues for PSP toxins.
The discovery of two pulsating subdwarf B stars in NGC 6791 using Kepler data
NASA Astrophysics Data System (ADS)
Reed, M. D.; Baran, A.; Østensen, R. H.; Telting, J.; O'Toole, S. J.
2012-12-01
We report the discovery of two new pulsating subdwarf B (sdB) stars in the open cluster NGC 6791 using data from the Kepler spacecraft. Three sdB stars were observed for one month in short-cadence (1 min) mode and three months in long-cadence (30 min) mode during Quarter 11 (fall 2011). The stars have Kepler Input Catalogue numbers of 2437937, 2569576 and 2569583 with previous designations of B5, B3 and B6, respectively. Another sdB star exists in the cluster and it is also known to be a pulsator. We also obtained Nordic Optical Telescope spectra to update effective temperatures, surface gravities and helium abundances and compare the spectroscopic properties of all four stars on a uniform model grid. We detect four periodicities between 0.9 and 2.4 h in B3 above a detection limit of 0.53 parts per thousand (ppt) and nine periodicities between 1.1 and 2.2 h in B5 above a detection limit of 0.37 ppt. No pulsations were detected in B6 to the detection threshold of 0.29 ppt. The long-cadence data were less useful as few observations are obtained per pulsation period, yet they do indicate that the pulsations are variable from month to month. The spacings between the pulsation periods are similar to other g-mode pulsating sdB stars observed by Kepler, indicating that the periodicities can be associated witquals; 1 modes. A fit to the periods give spacings of 234.6 ± 0.6 and 242.6 ± 1.5 s for B3 and B5, respectively.
Sadak, Omer; Sundramoorthy, Ashok K; Gunasekaran, Sundaram
2017-03-15
We report a highly selective method for identification and detection of iron (III) (ferric iron, Fe 3+ ) using Nile red (NR) as a complexing agent. Fe 3+ preferentially binds with NR in dimethylformamide (DMF)/water (1:1) solution over other cations such as Fe 2+ , Cu 2+ , Pb 2+ , Hg 2+ , Mn 2+ , Ni 2+ , Zn 2+ , Co 2+ and Cd 2+ at room temperature. In the presence of Fe 3+ , the color of NR solution changes from purple to dark brown, which is detectable with bare eyes. Using UV-vis spectroscopy, we could measure the amount of Fe 3+ in the sample solution by monitoring changes in absorption from 540 to 580nm; the linear range and the limit of detection are 30-1000µM and 24.9µM, respectively. Taking advantage of the NR selectivity, we treated partially oxidized graphene sheets (po-Gr) with NR to obtain po-Gr-NR dispersion by ultrasonication. The NR-treated po-Gr flakes (po-Gr-NR) were characterized by UV-vis, FT-IR, and Raman spectroscopies and FE-SEM, which indicated attachment of NR on po-Gr sheets. The po-Gr-NR hybrid film deposited glassy carbon electrode (po-Gr-NR/GCE) served as the Fe 3+ sensor. Differential pulse voltammetry was used to investigate the detection of Fe 3+ in 0.05M HCl+0.05M KCl solution. The linear range and the limit of detection of Fe 3+ were from 37.5nM to 21.53µM and 18.7nM, respectively. Furthermore, this sensor was successfully used to measure Fe 3+ content in red wine samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Kahoun, David; Rezková, Sona; Veskrnová, Katerina; Královský, Josef; Holcapek, Michal
2008-08-15
The objective of this study was the determination of 25 phenolic compounds in different mead samples (honeywines) using high performance liquid chromatography (HPLC) with coulometric-array detection and in case of hydroxymethylfurfural with UV detection. Our method was optimized in respect to both the separation selectivity of individual phenolic compounds and the maximum sensitivity with the electrochemical detection. The method development included the optimization of mobile phase composition, the pH value, conditions of the gradient elution and the flow rate using a window-diagram approach. The developed method was used for the determination of limits of detection and limits of quantitation for individual compounds. The linearity of calibration curves, accuracy and precision (intra- and inter-day) at three concentration levels (low, middle and high concentration range) were verified. Mead samples were diluted with the mobile phase at 1:1 to 1:50 ratio depending on the concentration and filtered through a PTFE filter without any other sample pre-treatment. Phenolic compounds concentration was determined in 50 real samples of meads and correlated with meads composition and hydroxymethylfurfural concentration. The most frequently occurred compounds were protocatechuic acid and vanillic acid (both of them were present in 98% samples), the least occurred compounds were (+)-catechin (10% samples) and sinapic acid (12% samples). Vanillin and ethylvanillin, which are used as artificial additives for the taste improvement, were found in 60% and 42% samples, respectively. Hydroxymethylfurfural concentration, as an indicator of honey quality, was in the range from 2.47 to 158 mg/L. Our method is applicable for the determination of 25 phenolic compounds in mead, honey and related natural samples.
Report on Analyses of WAC Samples of Evaporator Overheads - 2004
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L
2005-03-18
In November and December of 2004, the Tank Farm submitted annual samples from 2F, 2H and 3H Evaporator Overhead streams for characterization to verify compliance with the new Effluent Treatment Facility (ETF) Waste Acceptance Criteria (WAC) and to look for organic species. With the exception of slightly high ammonia in the 2F evaporator overheads and high radiation control guide number for the 3H and 2F evaporator overhead samples, all the overheads samples were found to be in compliance with the Effluent Treatment Facility WAC. The ammonium concentration in the 2F-evaporator overhead, at 33 mg/L, was above the ETF waste watermore » collection tank (WWCT) limits of 28 mg/L. The RCG Number for the 3H and 2F evaporator samples at, respectively, 1.38E-02 and 8.24E-03 were higher than the WWCT limit of 7.69E-03. The analytical detection limits for americium-241 and radium-226 in the evaporator samples were not consistently met because of low WWCT detection limits and insufficient evaporator samples.« less
Comparative psychophysics of bumblebee and honeybee colour discrimination and object detection.
Dyer, Adrian G; Spaethe, Johannes; Prack, Sabina
2008-07-01
Bumblebee (Bombus terrestris) discrimination of targets with broadband reflectance spectra was tested using simultaneous viewing conditions, enabling an accurate determination of the perceptual limit of colour discrimination excluding confounds from memory coding (experiment 1). The level of colour discrimination in bumblebees, and honeybees (Apis mellifera) (based upon previous observations), exceeds predictions of models considering receptor noise in the honeybee. Bumblebee and honeybee photoreceptors are similar in spectral shape and spacing, but bumblebees exhibit significantly poorer colour discrimination in behavioural tests, suggesting possible differences in spatial or temporal signal processing. Detection of stimuli in a Y-maze was evaluated for bumblebees (experiment 2) and honeybees (experiment 3). Honeybees detected stimuli containing both green-receptor-contrast and colour contrast at a visual angle of approximately 5 degrees , whilst stimuli that contained only colour contrast were only detected at a visual angle of 15 degrees . Bumblebees were able to detect these stimuli at a visual angle of 2.3 degrees and 2.7 degrees , respectively. A comparison of the experiments suggests a tradeoff between colour discrimination and colour detection in these two species, limited by the need to pool colour signals to overcome receptor noise. We discuss the colour processing differences and possible adaptations to specific ecological habitats.
A label-free aptamer-fluorophore assembly for rapid and specific detection of cocaine in biofluids.
Roncancio, Daniel; Yu, Haixiang; Xu, Xiaowen; Wu, Shuo; Liu, Ran; Debord, Joshua; Lou, Xinhui; Xiao, Yi
2014-11-18
We report a rapid and specific aptamer-based method for one-step cocaine detection with minimal reagent requirements. The feasibility of aptamer-based detection has been demonstrated with sensors that operate via target-induced conformational change mechanisms, but these have generally exhibited limited target sensitivity. We have discovered that the cocaine-binding aptamer MNS-4.1 can also bind the fluorescent molecule 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND) and thereby quench its fluorescence. We subsequently introduced sequence changes into MNS-4.1 to engineer a new cocaine-binding aptamer (38-GC) that exhibits higher affinity to both ligands, with reduced background signal and increased signal gain. Using this aptamer, we have developed a new sensor platform that relies on the cocaine-mediated displacement of ATMND from 38-GC as a result of competitive binding. We demonstrate that our sensor can detect cocaine within seconds at concentrations as low as 200 nM, which is 50-fold lower than existing assays based on target-induced conformational change. More importantly, our assay achieves successful cocaine detection in body fluids, with a limit of detection of 10.4, 18.4, and 36 μM in undiluted saliva, urine, and serum samples, respectively.
Limits to the Fraction of High-energy Photon Emitting Gamma-Ray Bursts
NASA Astrophysics Data System (ADS)
Akerlof, Carl W.; Zheng, WeiKang
2013-02-01
After almost four years of operation, the two instruments on board the Fermi Gamma-ray Space Telescope have shown that the number of gamma-ray bursts (GRBs) with high-energy photon emission above 100 MeV cannot exceed roughly 9% of the total number of all such events, at least at the present detection limits. In a recent paper, we found that GRBs with photons detected in the Large Area Telescope have a surprisingly broad distribution with respect to the observed event photon number. Extrapolation of our empirical fit to numbers of photons below our previous detection limit suggests that the overall rate of such low flux events could be estimated by standard image co-adding techniques. In this case, we have taken advantage of the excellent angular resolution of the Swift mission to provide accurate reference points for 79 GRB events which have eluded any previous correlations with high-energy photons. We find a small but significant signal in the co-added field. Guided by the extrapolated power-law fit previously obtained for the number distribution of GRBs with higher fluxes, the data suggest that only a small fraction of GRBs are sources of high-energy photons.
Du, Jiayan; Zhao, Mengxin; Huang, Wei; Deng, Yuequan; He, Yi
2018-05-09
We report a molybdenum oxide (MoO 3 ) nanomaterial-based three-input logic gate that uses Sn 2+ , NO 2 - , and H + ions as inputs. Under acidic conditions, Sn 2+ is able to reduce MoO 3 nanosheets, generating oxygen-vacancy-rich MoO 3-x nanomaterials along with strong localized surface plasmon resonance (LSPR) and an intense blue solution as the output signal. When NO 2 - is introduced, the redox reaction between the MoO 3 nanosheets and Sn 2+ is strongly inhibited because the NO 2 - consumes both H + and Sn 2+ . The three-input logic gate was employed for the visual colorimetric detection of Sn 2+ and NO 2 - under different input states. The colorimetric assay's limit of detection for Sn 2+ and the lowest concentration of NO 2 - detectable by the assay were found to be 27.5 nM and 0.1 μM, respectively. The assay permits the visual detection of Sn 2+ and NO 2 - down to concentrations as low as 2 μM and 25 μM, respectively. The applicability of the logic-gate-based colorimetric assay was demonstrated by using it to detect Sn 2+ and NO 2 - in several water sources.
NASA Astrophysics Data System (ADS)
Wachiralurpan, Sirirat; Sriyapai, Thayat; Areekit, Supatra; Sriyapai, Pichapak; Augkarawaritsawong, Suphitcha; Santiwatanakul, Somchai; Chansiri, Kosum
2018-04-01
ABSTRACT Listeria monocytogenes is a major foodborne pathogen of global health concern. Herein, the rapid diagnosis of L. monocytogenes has been achieved using loop-mediated isothermal amplification (LAMP) based on the phosphatidylcholine-phospholipase C gene (plcB). Colorimetric detection was then performed through the formation of DNA concatemers and a gold nanoparticle/DNA probe complex (GNP/DNA probe). The overall detection process was accomplished within approximately 1 h with no need for complicated equipment. The limits of detection for L. monocytogenes in the forms of purified genomic DNA and pure culture were 800 fg and 2.82 CFU mL-1, respectively. No cross reactions were observed from closely related bacteria species. The LAMP-GNP/DNA probe assay was applied to the detection of 200 raw chicken meat samples and compared to routine standard methods. The data revealed that the specificity, sensitivity and accuracy were 100%, 90.20% and 97.50%, respectively. The present assay was 100% in conformity with LAMP-agarose gel electrophoresis assay. Five samples that were negative by both assays appeared to have the pathogen at below the level of detection. The assay can be applied as a rapid direct screening method for L. monocytogenes.
Detection and discrimination of Mycobacterium tuberculosis complex.
Issa, Rahizan; Mohd Hassan, Nurul Akma; Abdul, Hatijah; Hashim, Siti Hasmah; Seradja, Valentinus H; Abdul Sani, Athirah
2012-01-01
A real-time quantitative polymerase chain reaction (qPCR) was developed for detection and discrimination of Mycobacterium tuberculosis (H37Rv and H37Ra) and M. bovis bacillus Calmette-Guérin (BCG) of the Mycobacterium tuberculosis complex (MTBC) from mycobacterial other than tuberculosis (MOTT). It was based on the melting curve (Tm) analysis of the gyrB gene using SYBR(®) Green I detection dye and the LightCycler 1.5 system. The optimal conditions for the assay were 0.25 μmol/L of primers with 3.1 mmol/L of MgCl(2) and 45 cycles of amplification. For M. tuberculosis (H37Rv and H37Ra) and M. bovis BCG of the MTBC, we detected the crossing points (Cp) at cycles of 16.96 ± 0.07, 18.02 ± 0.14, and 18.62 ± 0.09, respectively, while the Tm values were 90.19 ± 0.06 °C, 90.27 ± 0.09 °C, and 89.81 ± 0.04 °C, respectively. The assay was sensitive and rapid with a detection limit of 10 pg of the DNA template within 35 min. In this study, the Tm analysis of the qPCR assay was applied for the detection and discrimination of MTBC from MOTT. Copyright © 2012 Elsevier Inc. All rights reserved.
Salama, Orly; Herrmann, Sebastien; Tziknovsky, Alina; Piura, Benjamin; Meirovich, Michael; Trakht, Ilya; Reed, Brent; Lobel, Leslie I; Marks, Robert S
2007-02-15
We report herein the development of an optical fiber based chemiluminescent immunosensor for detection of the native autoimmune response to GIPC-1, a PDZ containing protein involved in regulation of G-protein signaling. The recombinant protein GIPC-1 was expressed in bacteria, purified, refolded and conjugated to the tip of an optical fiber. A human monoclonal 27.B1 IgM isolated from a breast cancer patient, which targets the GIPC-1 protein, was used for calibration of the immunosensor and was detected down to a concentration of 30 pg/ml. We determined that the fiber-optic immunosensor had a detection limit 50 times lower than chemiluminescent ELISA, and approximately 500 times lower than colorimetric ELISA. In addition, sera from 11 ovarian cancer patients, 22 breast cancer patients and asymptomatic controls were tested for the presence of IgM anti-GIPC-1 autoantibodies in their serum using the two methods. The immunosensor assay detected 54% and 77% GIPC-1 positive sera within ovarian and breast cancer patients, respectively, as compared to chemiluminescent ELISA, which only detected 18% and 27%, respectively. We envision that this immunosensor may serve as a diagnostic tool for screening women for ovarian and breast cancer at an early stage, thus increasing their chance of survival.
Timms, Mark; Hall, Nikki; Levina, Vita; Vine, John; Steel, Rohan
2014-10-01
The growth hormone releasing peptides (GHRPs) hexarelin, ipamorelin, alexamorelin, GHRP-1, GHRP-2, GHRP-4, GHRP-5, and GHRP-6 are all synthetic met-enkephalin analogues that include unnatural D-amino acids. They were designed specifically for their ability to stimulate growth hormone release and may serve as performance enhancing drugs. To regulate the use of these peptides within the horse racing industry and by human athletes, a method is presented for the extraction, derivatization, and detection of GHRPs from equine and human urine. This method takes advantage of a highly specific solid-phase extraction combined with a novel derivatization method to improve the chromatography of basic peptides. The method was validated with respect to linearity, repeatability, intermediate precision, specificity, limits of detection, limits of confirmation, ion suppression, and stability. As proof of principle, all eight GHRPs or their metabolites could be detected in urine collected from rats after intravenous administration. Copyright © 2014 John Wiley & Sons, Ltd.
The evens and odds of CMB anomalies
NASA Astrophysics Data System (ADS)
Gruppuso, A.; Kitazawa, N.; Lattanzi, M.; Mandolesi, N.; Natoli, P.; Sagnotti, A.
2018-06-01
The lack of power of large-angle CMB anisotropies is known to increase its statistical significance at higher Galactic latitudes, where a string-inspired pre-inflationary scale Δ can also be detected. Considering the Planck 2015 data, and relying largely on a Bayesian approach, we show that the effect is mostly driven by the even - ℓ harmonic multipoles with ℓ ≲ 20, which appear sizably suppressed in a way that is robust with respect to Galactic masking, along with the corresponding detections of Δ. On the other hand, the first odd - ℓ multipoles are only suppressed at high Galactic latitudes. We investigate this behavior in different sky masks, constraining Δ through even and odd multipoles, and we elaborate on possible implications. We include low- ℓ polarization data which, despite being noise-limited, help in attaining confidence levels of about 3 σ in the detection of Δ. We also show by direct forecasts that a future all-sky E-mode cosmic-variance-limited polarization survey may push the constraining power for Δ beyond 5 σ.
Analysis of bakery products by laser-induced breakdown spectroscopy.
Bilge, Gonca; Boyacı, İsmail Hakkı; Eseller, Kemal Efe; Tamer, Uğur; Çakır, Serhat
2015-08-15
In this study, we focused on the detection of Na in bakery products by using laser-induced breakdown spectroscopy (LIBS) as a quick and simple method. LIBS experiments were performed to examine the Na at 589 nm to quantify NaCl. A series of standard bread sample pellets containing various concentrations of NaCl (0.025-3.5%) were used to construct the calibration curves and to determine the detection limits of the measurements. Calibration graphs were drawn to indicate functions of NaCl and Na concentrations, which showed good linearity in the range of 0.025-3.5% NaCl and 0.01-1.4% Na concentrations with correlation coefficients (R(2)) values greater than 0.98 and 0.96. The obtained detection limits for NaCl and Na were 175 and 69 ppm, respectively. Performed experimental studies showed that LIBS is a convenient method for commercial bakery products to quantify NaCl concentrations as a rapid and in situ technique. Copyright © 2015 Elsevier Ltd. All rights reserved.
Amperometric Sensor for Detection of Chloride Ions.
Trnkova, Libuse; Adam, Vojtech; Hubalek, Jaromir; Babula, Petr; Kizek, Rene
2008-09-15
Chloride ion sensing is important in many fields such as clinical diagnosis, environmental monitoring and industrial applications. We have measured chloride ions at a carbon paste electrode (CPE) and at a CPE modified with solid AgNO₃, a solution of AgNO₃ and/or solid silver particles. Detection limits (3 S/N) for chloride ions were 100 μM, 100 μM and 10 μM for solid AgNO₃, solution of AgNO₃ and/or solid silver particles, respectively. The CPE modified with silver particles is the most sensitive to the presence chloride ions. After that we approached to the miniaturization of the whole electrochemical instrument. Measurements were carried out on miniaturized instrument consisting of a potentiostat with dimensions 35 × 166 × 125 mm, screen printed electrodes, a peristaltic pump and a PC with control software. Under the most suitable experimental conditions (Britton-Robinson buffer, pH 1.8 and working electrode potential 550 mV) we estimated the limit of detection (3 S/N) as 500 nM.
Chen, Juan; Ma, Xue-Mei; Shi, Yan-Ping
2009-01-01
A high-performance liquid chromatographic technique coupled with photodiode array detection was proposed for the simultaneous determination of 7 flavonoids, i.e., quercetin, kaempferol, 7-hydroxyflavanone, 7-methoxyflavanone, 2',4'-dihydroxychalcone, 2',4'-dihydroxydihydrochalcone, and 7,2'-dihydroxy-3', 4'-dimethoxyisoflavane, in extracts of the plant Ixeridium gracile. Optimum separation was obtained by using a reversed-phase C18 method. Because of the different UV characteristics of these components, 5 detection wavelengths were used for the quantitative analysis. All of the flavonoids showed good linearity (r > 0.9999). The limit of detection and limit of quantitation values for the analytes ranged from 0.06 to 0.46 microg/mL and from 0.18 to 1.48 microg/mL, respectively. The method was validated by evaluating repeatability, precision, stability, and accuracy. Five different extraction and purification procedures were investigated for preparation of the sample solution. The optimized method was applied to the determination of flavonoids in I. gracile and was found to be efficient.
Indirect signals from solar dark matter annihilation to long-lived right-handed neutrinos
Allahverdi, Rouzbeh; Gao, Yu; Knockel, Bradley; ...
2017-04-04
In this paper, we study indirect detection signals from solar annihilation of dark matter (DM) particles into light right-handed (RH) neutrinos with a mass in a 1–5 GeV range. These RH neutrinos can have a sufficiently long lifetime to allow them to decay outside the Sun, and their delayed decays can result in a signal in gamma rays from the otherwise “dark” solar direction, and also a neutrino signal that is not suppressed by the interactions with solar medium. We find that the latest Fermi-LAT and IceCube results place limits on the gamma ray and neutrino signals, respectively. Combined photonmore » and neutrino bounds can constrain the spin-independent DM-nucleon elastic scattering cross section better than direct detection experiments for DM masses from 200 GeV up to several TeV. Finally, the bounds on spin-dependent scattering are also much tighter than the strongest limits from direct detection experiments.« less
[Determination of inorganic ions in explosive residues by capillary zone electrophoresis].
Feng, Junhe; Guo, Baoyuan; Lin, Jin-Ming; Xu, Jianzhong; Zhou, Hong; Sun, Yuyou; Liu, Yao; Quan, Yangke; Lu, Xiaoming
2008-11-01
Five anions (chlorate, perchlorate, nitrate, nitrite, and sulfate) and two cations (ammonium and potassium) in explosive residues have been separated and determined by capillary zone electrophoresis (CZE) with indirect ultraviolet detection. The electrolyte buffer for the cation separation was 10 mmol/L pyridine (pH 4.5) -3 mmol/L 18-crown-6-ether. Ammonium and potassium ions were baseline separated in less than 2.6 min with the detection limits of 0.10 mg/L and 0.25 mg/L (S/N = 3), respectively. The electrolyte buffer for the anion separation consisted of 40 mmol/L boric acid-1.8 mmol/L potassium dichromate-2 mmol/L sodium tetraborate (pH 8.6), and tetramethyl ammonium hydroxide (TMAOH) was used as electroosmotic flow modifier. All five anions were well separated in less than 4.6 min with the detection limit range of 0.10 - 1.85 mg/L (S/N = 3). The method was successfully used in real sample investigations to confirm the type of explosives.
Survey for the presence of a vitronectin-like protein in micro- and macroalgae and cyanobacteria.
Field, Lacey M; Fagerberg, Wayne R; Böttger, S Anne
2018-04-01
Vitronectin (Vn) is a glycoprotein that serves a wide variety of roles in multicellular organisms. It was first identified in multicellular animals but has also been isolated from land plants and some algae, where it appears to serve as an extracellular adhesive molecule. In order to further elucidate presence and localization of a Vn-like protein and its potential role in algae, we surveyed different morphological regions of 24 species of macro- and microalgae and three species of cyanobacteria for the presence of a Vn-like protein. Vn-like proteins were not detected in any of the species of cyanobacteria, microalgae or Rhodophyta investigated. They were detected in several species of the Phaeophyceae and Chlorophyta where their localization was limited to the holdfast and rhizoids of these organisms, respectively. Detection of a Vn-like protein (between 0.0125 and 0.097 μg · μL -1 protein extract) was therefore limited to locations associated with substrate attachment. © 2017 Phycological Society of America.
Kim, Hye Jin; Kim, Jinsik; Yoo, Yong Kyoung; Lee, Jeong Hoon; Park, Jung Ho; Hwang, Kyo Seon
2016-11-15
Effective control of nano-scale biomolecules can enhance the sensitivity and limit of detection of an interdigitated microelectrode (IME) sensor. Manipulation of the biomolecules by dielectrophoresis (DEP), especially the negative DEP (nDEP) force, so that they are trapped between electrodes (sensing regions) was predicted to increase the binding efficiency of the antibody and target molecules, leading to a more effective reaction. To prove this concept, amyloid beta 42 (Aβ42) and prostate specific antigen (PSA) protein were respectively trapped between the sensing region owing to the nDEP force under 5V and 0.05V, which was verified with COMSOL simulation. Using the simulation value, the resistance change (ΔR/Rb) of the IME sensor from the specific antibody-antigen reaction of the two biomolecules and the change in fluorescence intensity were compared in the reference (pDEP) and nDEP conditions. The ΔR/Rb value improved by about 2-fold and 1.66-fold with nDEP compared to the reference condition with various protein concentrations, and these increases were confirmed with fluorescence imaging. Overall, nDEP enhanced the detection sensitivity for Aβ42 and PSA by 128% and 258%, respectively, and the limit of detection improved by up to 2-orders of magnitude. These results prove that DEP can improve the biosensor's performance. Copyright © 2016 Elsevier B.V. All rights reserved.
Complex organic molecules during low-mass star formation: Pilot survey results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Öberg, Karin I.; Graninger, Dawn; Lauck, Trish, E-mail: koberg@cfa.harvard.edu
Complex organic molecules (COMs) are known to be abundant toward some low-mass young stellar objects (YSOs), but how these detections relate to typical COM abundance are not yet understood. We aim to constrain the frequency distribution of COMs during low-mass star formation, beginning with this pilot survey of COM lines toward six embedded YSOs using the IRAM 30 m Telescope. The sample was selected from the Spitzer c2d ice sample and covers a range of ice abundances. We detect multiple COMs, including CH{sub 3}CN, toward two of the YSOs, and tentatively toward a third. Abundances with respect to CH{sub 3}OHmore » vary between 0.7% and 10%. This sample is combined with previous COM observations and upper limits to obtain a frequency distributions of CH{sub 3}CN, HCOOCH{sub 3}, CH{sub 3}OCH{sub 3}, and CH{sub 3}CHO. We find that for all molecules more than 50% of the sample have detections or upper limits of 1%-10% with respect to CH{sub 3}OH. Moderate abundances of COMs thus appear common during the early stages of low-mass star formation. A larger sample is required, however, to quantify the COM distributions, as well as to constrain the origins of observed variations across the sample.« less
Ali, Arslan; Haq, Faraz Ul; Ul Arfeen, Qamar; Sharma, Khaga Raj; Adhikari, Achyut; Musharraf, Syed Ghulam
2017-10-01
Diabetes is a major global health problem which requires new studies for its prevention and control. Scoparia dulcis, a herbal product, is widely used for treatment of diabetes. Recent studies demonstrate coixol as a potent and nontoxic insulin secretagog from S. dulcis. This study focuses on developing two quantitative methods of coixol in S. dulcis methanol-based extracts. Quantification of coixol was performed using high-performance liquid chromatography-tandem mass spectrometry (method 1) and high-performance liquid chromatography-ultraviolet detection (method 2) with limits of detection of 0.26 and 11.6 pg/μL, respectively, and limits of quantification of 0.78 and 35.5 pg/μL, respectively. S. dulcis is rich in coixol content with values of 255.5 ± 2.1 mg/kg (method 1) and 220.4 ± 2.9 mg/kg (method 2). Excellent linearity with determination coefficients >0.999 was achieved for calibration curves from 10 to 7500 ng/mL (method 1) and from 175 to 7500 ng/mL (method 2). Good accuracy (bias < -8.6%) and precision (RSD < 8.5%) were obtained for both methods. Thus, they can be employed to analyze coixol in plant extracts and herbal formulations. Copyright © 2017 John Wiley & Sons, Ltd.
Saeidi, Iman; Barfi, Behruz; Payrovi, Moazameh; Feizy, Javid; Sheibani, Hojat A; Miri, Mina; Ghollasi Moud, Farahnaz
2015-01-01
With polyamide (PA) as an efficient sorbent for solid phase extraction (SPE) of Sudan dyes II, III and Red 7B from saffron and urine, their determination by HPLC was performed. The optimum conditions for SPE were achieved using 7 mL methanol/water (1:9, v/v, pH 7) as the washing solvent and 3 mL tetrahydrofuran for elution. Good clean-up and high (above 90%) recoveries were observed for all the analytes. The optimized mobile phase composition for HPLC analysis of these compounds was methanol-water (70:30, v/v). The SPE parameters, such as the maximum loading capacity and breakthrough volume, were also determined for each analyte. The limits of detection (LODs), limits of quantification (LOQs), linear ranges and recoveries for the analytes were 4.6-6.6 microg/L, 13.0-19.8 microg/L, 13.0-5000 microg/L (r2>0.99) and 92.5%-113.4%, respectively. The precisions (RSDs) of the overall analytical procedure, estimated by five replicate measurements for Sudan II, III and Red 7B in saffron and urine samples were 2.3%, 1.8% and 3.6%, respectively. The developed method is simple and successful in the application to the determination of Sudan dyes in saffron and urine samples with HPLC coupled with UV detection.
Ma, Yan; Xie, Jiawen; Jin, Jing; Wang, Wei; Yao, Zhijian; Zhou, Qing; Li, Aimin; Liang, Ying
2015-07-01
A novel magnetic solid phase extraction coupled with high-performance liquid chromatography method was established to analyze polyaromatic hydrocarbons in environmental water samples. The extraction conditions, including the amount of extraction agent, extraction time, pH and the surface structure of the magnetic extraction agent, were optimized. The results showed that the amount of extraction agent and extraction time significantly influenced the extraction performance. The increase in the specific surface area, the enlargement of pore size, and the reduction of particle size could enhance the extraction performance of the magnetic microsphere. The optimized magnetic extraction agent possessed a high surface area of 1311 m(2) /g, a large pore size of 6-9 nm, and a small particle size of 6-9 μm. The limit of detection for phenanthrene and benzo[g,h,i]perylene in the developed analysis method was 3.2 and 10.5 ng/L, respectively. When applied to river water samples, the spiked recovery of phenanthrene and benzo[g,h,i]perylene ranged from 89.5-98.6% and 82.9-89.1%, respectively. Phenanthrene was detected over a concentration range of 89-117 ng/L in three water samples withdrawn from the midstream of the Huai River, and benzo[g,h,i]perylene was below the detection limit. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Derpmann, Valerie; Mueller, David; Bejan, Iustinian; Sonderfeld, Hannah; Wilberscheid, Sonja; Koppmann, Ralf; Brockmann, Klaus J; Benter, Thorsten
2014-03-01
We report on a novel method for atmospheric pressure ionization of compounds with elevated electron affinity (e.g., nitroaromatic compounds) or gas phase acidity (e.g., phenols), respectively. The method is based on the generation of thermal electrons by the photo-electric effect, followed by electron capture of oxygen when air is the gas matrix yielding O2(-) or of the analyte directly with nitrogen as matrix. Charge transfer or proton abstraction by O2(-) leads to the ionization of the analytes. The interaction of UV-light with metals is a clean method for the generation of thermal electrons at atmospheric pressure. Furthermore, only negative ions are generated and neutral radical formation is minimized, in contrast to discharge- or dopant assisted methods. Ionization takes place inside the transfer capillary of the mass spectrometer leading to comparably short transfer times of ions to the high vacuum region of the mass spectrometer. This strongly reduces ion transformation processes, resulting in mass spectra that more closely relate to the neutral analyte distribution. cAPECI is thus a soft and selective ionization method with detection limits in the pptV range. In comparison to standard ionization methods (e.g., PTR), cAPECI is superior with respect to both selectivity and achievable detection limits. cAPECI demonstrates to be a promising ionization method for applications in relevant fields as, for example, explosives detection and atmospheric chemistry.
2014-01-01
Background Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). Methods The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. Results The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Conclusions Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care. PMID:24593868
Watanabe, Reina; Shimoda, Tomoko; Yano, Rika; Hayashi, Yasuhiro; Nakamura, Shinji; Matsuo, Junji; Yamaguchi, Hiroyuki
2014-03-04
Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care.
NASA Astrophysics Data System (ADS)
Chan, Tzu-Yi; Liu, Ting-Yu; Wang, Kuan-Syun; Tsai, Kun-Tong; Chen, Zhi-Xin; Chang, Yu-Chi; Tseng, Yi-Qun; Wang, Chih-Hao; Wang, Juen-Kai; Wang, Yuh-Lin
2017-05-01
This paper describes the preparation of nanoarrays composed of silver nanoparticles (AgNPs: 20-50 nm) for use as surface-enhanced Raman scattering (SERS) substrates. The AgNPs were grown on porous anodic aluminum oxide (AAO) templates by electrochemical plating, and the inter-channel gap of AAO channels is between 10 and 20 nm. The size and interparticle gap of silver particles were adjusted in order to achieve optimal SERS signals and characterized by scanning electron microscopy, atomic force microscopy, and Raman spectroscopy. The fluctuation of SERS intensity is about 10-20% when measuring adenine solutions, showing a great reproducible SERS sensing. The nanoparticle arrays offer a large potential for practical applications as shown by the SERS-based quantitative detection and differentiation of adenine (A), thymine (T), cytosine (C), guanine (G), β-carotene, and malachite green. The respective detection limits are <1 ppb for adenine and <0.63 ppm for β-carotene and malachite green, respectively.
Virological and bacteriological quality of drinking water in Ethiopia
NASA Astrophysics Data System (ADS)
Bedada, Tesfaye Legesse; Mezemir, Walelign Dessie; Dera, Firehiwot Abera; Sima, Waktole Gobena; Gebre, Samson Girma; Edicho, Redwan Muzeyin; Biegna, Almaz Gonfa; Teklu, Dejenie Shiferaw; Tullu, Kassu Desta
2018-05-01
Since unsafe water is responsible for many illness, deaths, and economic failure, water quality monitoring is essential. A cross-sectional study was conducted on 218 drinking waters samples collected between February and June 2016 to assess water quality using phages by the help of CB390 E. coli host, plaque assay; multiple tube fermentation for coliforms and pour plate for heterotrophic bacteria at Ethiopian Public Health Institute. Heterotrophic plate count greater than 100 cfu/ml was noted in 41 samples and detections of total and thermotolerant coliforms and E. coli in 38, 24, and 10 samples, respectively, and no phages detection in chlorinated waters. While heterotrophic plate count greater than 100 cfu/ml was observed in 100 samples and detections of total and thermotolerant coliforms, E. coli, and phages in 75, 60, 42, and 5 samples, respectively, for untreated waters. The majority of the waters contained indicators above standard limits. This indicates that the sources are contaminated and they are potential threats for health. Hence, regular water monitoring should be a priority agenda.
Fegade, Umesh A; Sahoo, Suban K; Singh, Amanpreet; Singh, Narinder; Attarde, Sanjay B; Kuwar, Anil S
2015-05-04
A fluorescent based receptor (4Z)-4-(4-diethylamino)-2-hydroxybenzylidene amino)-1,2dihydro-1,5-dimethyl-2-phenylpyrazol-3-one (receptor 3) was developed for the highly selective and sensitive detection of Cu(2+) and Zn(2+) in semi-aqueous system. The fluorescence of receptor 3 was enhanced and quenched, respectively, with the addition of Zn(2+) and Cu(2+) ions over other surveyed cations. The receptor formed host-guest complexes in 1:1 stoichiometry with the detection limit of 5 nM and 15 nM for Cu(2+) and Zn(2+) ions, respectively. Further, we have effectively utilized the two metal ions (Cu(2+) and Zn(2+)) as chemical inputs for the manufacture of INHIBIT type logic gate at molecular level using the fluorescence responses of receptor 3 at 450 nm. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhu, Jiping; Feng, Yong-Lai; Aikawa, Bio
2004-11-01
An analytical method for ethylene glycol and propylene glycols has been developed for measuring airborne levels of these chemicals in non-occupational environments such as residences and office buildings. The analytes were collected on charcoal tubes, solvent extracted, and analyzed by gas chromatography-mass spectrometry using a positive chemical ionization technique. The method had a method detection limit of 0.07 microg m(-3) for ethylene glycol and 0.03 microg m(-3) for 1,2- and 1,3-propylene glycols, respectively, based on a 1.44 m3 sampling volume. Indoor air samples of several residential homes and other indoor environments have been analyzed. The median concentrations of ethylene glycol and 1,2-propylene glycol in nine residential indoor air samples were 53 microg m(-3) and 13 microg m(-3) respectively with maximum values of 223 microg m(-3) and 25 microg m(-3) detected for ethylene glycol and 1,2-propylene glycol respectively. The concentrations of these two chemicals in one office and two laboratories were at low microg m(-3) levels. The maximum concentration of 1,3-propylene glycol detected in indoor air was 0.1 microg m(-3).
Explosives Detection: Exploitation of the Physical Signatures
NASA Astrophysics Data System (ADS)
Atkinson, David
2010-10-01
Explosives based terrorism is an ongoing threat that is evolving with respect to implementation, configuration and materials used. There are a variety of devices designed to detect explosive devices, however, each technology has limitations and operational constraints. A full understanding of the signatures available for detection coupled with the array of detection choices can be used to develop a conceptual model of an explosives screening operation. Physics based sensors provide a robust approach to explosives detection, typically through the identification of anomalies, and are currently used for screening in airports around the world. The next generation of detectors for explosives detection will need to be more sensitive and selective, as well as integrate seamlessly with devices focused on chemical signatures. An appreciation for the details of the physical signature exploitation in cluttered environments with time, space, and privacy constraints is necessary for effective explosives screening of people, luggage, cargo, and vehicles.
Salghi, Rachid; Armbruster, Wolfgang; Schwack, Wolfgang
2014-06-15
Triacylglycerol profiles were selected as indicator of adulteration of argan oils to carry out a rapid screening of samples for the evaluation of authenticity. Triacylglycerols were separated by high-performance liquid chromatography-evaporative light scattering detection. Different peak area ratios were defined to sensitively detect adulteration of argan oil with vegetable oils such as sunflower, soy bean, and olive oil up to the level of 5%. Based on four reference argan oils, mean limits of detection and quantitation were calculated to approximately 0.4% and 1.3%, respectively. Additionally, 19 more argan oil reference samples were analysed by high-performance liquid chromatography-refractive index detection, resulting in highly comparative results. The overall strategy demonstrated a good applicability in practise, and hence a high potential to be transferred to routine laboratories. Copyright © 2013 Elsevier Ltd. All rights reserved.
Study of gamma detection capabilities of the REWARD mobile spectroscopic system
NASA Astrophysics Data System (ADS)
Balbuena, J. P.; Baptista, M.; Barros, S.; Dambacher, M.; Disch, C.; Fiederle, M.; Kuehn, S.; Parzefall, U.
2017-07-01
REWARD is a novel mobile spectroscopic radiation detector system for Homeland Security applications. The system integrates gamma and neutron detection equipped with wireless communication. A comprehensive simulation study on its gamma detection capabilities in different radioactive scenarios is presented in this work. The gamma detection unit consists of a precise energy resolution system based on two stacked (Cd,Zn)Te sensors working in coincidence sum mode. The volume of each of these CZT sensors is 1 cm3. The investigated energy windows used to determine the detection capabilities of the detector correspond to the gamma emissions from 137Cs and 60Co radioactive sources (662 keV and 1173/1333 keV respectively). Monte Carlo and Technology Computer-Aided Design (TCAD) simulations are combined to determine its sensing capabilities for different radiation sources and estimate the limits of detection of the sensing unit as a function of source activity for several shielding materials.
Development and evaluation of novel sensing materials for detecting food contamination
NASA Astrophysics Data System (ADS)
Sankaran, Sindhuja
Rapid detection of food-borne volatile organic compounds (VOCs) such as organic acids and alcohols released by bacterial pathogens is being used as an indicator for detecting bacterial contamination in food by our research group. One of our current research thrusts is to develop novel sensors that will be sensitive to specific compounds (at low operating temperature) associated with food safety. This study evaluates two approaches employed to develop sensors for detecting acid and alcohols at low concentrations. Chemoresistive and piezoelectric sensors were developed based on metal oxides and olfactory system based biomaterials, respectively to detect acetic acid, butanol, 3-methyl-1-butanol, 1-pentanol, and 1-hexanol. The metal oxide based sensors were developed by the sol-gel method. A zinc oxide (ZnO) sensor was found to be sensitive to acetic acid with lower detection limit ranging from 13-40 ppm. The three-layered dip-coated gold electrode based ZnO sensors had a LDL of 18 ppm for acetic acid detection. The ZnO-iron oxide (Fe2O3) based nanocomposite sensors were developed to detect butanol operating at 100°C. The 5% Fe/Zn mole ratio based ZnO-Fe2O3 nanocomposite sensors had high correlation coefficients (>0.90) of calibration curves, low butanol LDLs (26 +/- 7 ppm), and lower variation among the sensor responses. The ZnO and ZnO-Fe2O3 nanocomposite sensors showed potential to detect acetic acid and butanol at low concentrations, respectively at 100°C. QCM based olfactory sensors were developed from olfactory receptor and odorant binding protein based sequences to detect low concentrations of acetic acid and alcohols (3-methyl-1-butanol and 1-hexanol), respectively. The average LDLs for acetic acid as well as alcohols detection of the QCM sensors were < 5 ppm. The linear calibration curve based correlation coefficients of the QCM sensors were > 0.80. Finally, a computational simulation based peptide sequences was designed from olfactory receptors and evaluated as sensor material for the detection of alcohols at low concentrations. The results indicated that the QCM sensors exhibited a good sensitivity to 1-hexanol and 1-pentanol with the estimated LDLs in the range of 2-3 ppm and 3-5 ppm, respectively. This research work was successful in developing multiple novel sensing materials to detect alcohols and acid associated with meat contaminations at low concentrations.
Sirichai, S; de Mello, A J
2001-01-01
The separation and detection of both print and film developing agents (CD-3 and CD-4) in photographic processing solutions using chip-based capillary electrophoresis is presented. For simultaneous detection of both analytes under identical experimental conditions a buffer pH of 11.9 is used to partially ionise the analytes. Detection is made possible by indirect fluorescence, where the ions of the analytes displace the anionic fluorescing buffer ion to create negative peaks. Under optimal conditions, both analytes can be analyzed within 30 s. The limits of detection for CD-3 and CD-4 are 0.17 mM and 0.39 mM, respectively. The applicability of the method for the analysis of seasoned photographic processing developer solutions is also examined.
Prakash, Neeraj; Ramachandran, Arun; Varma, Ravi; Chen, Jun; Mazzoleni, Claudio; Du, Ke
2018-06-28
The principle of near-infrared incoherent broadband cavity enhanced absorption spectroscopy was employed to develop a novel instrument for detecting natural gas leaks as well as for testing the quality of natural gas mixtures. The instrument utilizes the absorption features of methane, butane, ethane, and propane in the wavelength region of 1100 nm to 1250 nm. The absorption cross-section spectrum in this region for methane was adopted from the HITRAN database, and those for the other three gases were measured in the laboratory. A singular-value decomposition (SVD) based analysis scheme was employed for quantifying methane, butane, ethane, and propane by performing a linear least-square fit. The developed instrument achieved a detection limit of 460 ppm, 141 ppm, 175 ppm and 173 ppm for methane, butane, ethane, and propane, respectively, with a measurement time of 1 second and a cavity length of 0.59 m. These detection limits are less than 1% of the Lower Explosive Limit (LEL) for each gas. The sensitivity can be further enhanced by changing the experimental parameters (such as cavity length, lamp power etc.) and using longer averaging intervals. The detection system is a low-cost and portable instrument suitable for performing field monitorings. The results obtained on the gas mixture emphasize the instrument's potential for deployment at industrial facilities dealing with natural gas, where potential leaks pose a threat to public safety.
De Wild, John F.; Olsen, Mark L.; Olund, Shane D.
2002-01-01
A recent national sampling of streams in the United States revealed low methyl mercury concentrations in surface waters. The resulting median and mean concentrations, calculated from 104 samples, were 0.06 nanograms per liter (ng/L) and 0.15 ng/L, respectively. This level of methyl mercury in surface water in the United States has created a need for analytical techniques capable of detecting sub-nanogram per liter concentrations. In an attempt to create a U.S. Geological Survey approved method, the Wisconsin District Mercury Laboratory has adapted a distillation/ethylation/ gas-phase separation method with cold vapor atomic fluorescence spectroscopy detection for the determination of methyl mercury in filtered and unfiltered waters. This method is described in this report. Based on multiple analyses of surface water and ground-water samples, a method detection limit of 0.04 ng/L was established. Precision and accuracy were evaluated for the method using both spiked and unspiked ground-water and surface-water samples. The percent relative standard deviations ranged from 10.2 to 15.6 for all analyses at all concentrations. Average recoveries obtained for the spiked matrices ranged from 88.8 to 117 percent. The precision and accuracy ranges are within the acceptable method-performance limits. Considering the demonstrated detection limit, precision, and accuracy, the method is an effective means to quantify methyl mercury in waters at or below environmentally relevant concentrations
Kechagia, Maria; Samanidou, Victoria; Kabir, Abuzar; Furton, Kenneth G
2018-02-01
A highly selective molecularly imprinted polymer sorbent was synthesized and employed for the simultaneous determination of six sulfonamide antibiotic residues (sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole, sulfamerazine, and sulfamethizole) in milk samples. Multi-analyte imprinted particles were used as a sorbent in solid-phase extraction. Sulfonamides were separated on a high-performance liquid chromatography column (Merck-Lichrospher RP18e, 5 μm 250 × 4 mm) and further identified and quantified by diode array detection. Several parameters including required loading of the molecularly imprinted polymer sorbent, mass of milk, volume, and type of elution solvent, as well as time for absorption and elution were investigated to obtain optimal experimental conditions. For comparison purpose, a non-imprinted polymer was applied under the optimum conditions. The validation study according to the European Union Decision 2002/657/EC was based on the investigation of linearity, selectivity, stability, limits of detection and quantitation, decision limit, detection capability, trueness, precision, and ruggedness according to Youden's approach. The decision limit and detection capability values in the milk were achieved from 101.9 to 113.5 μg/kg and from 114.4 to 135.4 μg/kg, respectively, depending on the target sulfonamide drug. Finally, the optimized protocol was successfully applied to commercial milk samples and human breast milk. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Shen, Yang; Zhou, Jianhua; Liu, Tianran; Tao, Yuting; Jiang, Ruibin; Liu, Mingxuan; Xiao, Guohui; Zhu, Jinhao; Zhou, Zhang-Kai; Wang, Xuehua; Jin, Chongjun; Wang, Jianfang
2013-08-01
Localized surface plasmon resonance (LSPR)-based sensing has found wide applications in medical diagnosis, food safety regulation and environmental monitoring. Compared with commercial propagating surface plasmon resonance (PSPR)-based sensors, LSPR ones are simple, cost-effective and suitable for measuring local refractive index changes. However, the figure of merit (FOM) values of LSPR sensors are generally 1-2 orders of magnitude smaller than those of PSPR ones, preventing the widespread use of LSPR sensors. Here we describe an array of submicrometer gold mushrooms with a FOM reaching ~108, which is comparable to the theoretically predicted upper limit for standard PSPR sensors. Such a high FOM arises from the interference between Wood’s anomaly and the LSPRs. We further demonstrate the array as a biosensor for detecting cytochrome c and alpha-fetoprotein, with their detection limits down to 200 pM and 15 ng ml-1, respectively, suggesting that the array is a promising candidate for label-free biomedical sensing.
Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X.C.; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping
2017-01-01
Abstract The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection. To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10. The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples. The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%. The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. PMID:29390519
Yoon, Na Ri; Park, Jae Myung; Jung, Hee Sun; Cho, Yu Kyung; Lee, In Seok; Choi, Myung Gyu; Chung, In Sik; Song, Kyo Young; Park, Cho Hyun
2012-05-01
The usefulness of ¹⁸F-fluoro-2-deoxyglucose (FDG)-PET in detecting primary cancer, lymph node metastasis, and distant metastasis were studied in the gastric cancer patients. The subjects were 392 gastric cancer patients who received FDG-PET and an abdominal CT test prior to surgery. The results of FDG-PET and CT were compared with the surgical and pathologic results. The primary site detection rate of FDG-PET was 74.4%, 50.3% in early gastric cancer and 92.0% in advanced gastric cancer. Detection rate was higher when tumors were larger than 3.5 cm, had deeper depth of invasion, and at a later stage (p<0.05, respectively). In multivariate analysis, tumor size, spread of tumor cells beyond the muscle layer (≥T2), and lymph node metastasis were statistically significant factors in primary site detection rate. The sensitivity, specificity, and positive predictive value of FDG-PET to lymph node metastasis were 59.6%, 88.8%, and 81.1% respectively, sensitivity being lower compared to CT while specificity and positive predictive value were higher. Sensitivity, specificity, and positive predictive value to distant metastasis were, respectively, 66.7%, 99.2%, and 88.0%, similar to CT. In 21 of the 392 patients (5.4%), synchronous double primary cancers were detected. In gastric cancer, usefullness of FDG-PET is limited to the advanced stage. Diagnostic value of this test was not superior to CT. However, FDG-PET may be useful in detecting synchronous double primary cancers.
Wu, Xiaoxin; Wang, Yeping; Weng, Tianhao; Hu, Chenyu; Wang, Frederick X C; Wu, Zhigang; Yu, Dongshan; Lu, Huoquan; Yao, Hangping
2017-12-01
The early secreted protein early secretory antigenic target 6(ESAT-6) and the culture filtrate protein 10 (CFP-10) are 2 antigens that are specific to Mycobacterium tuberculosis. These 2 antigens are good targets for tuberculosis (TB) detection.To rapidly diagnose TB across a variety of samples, we developed colloidal gold immunochromatographic strips (ICSs) based on ESAT-6 and CFP-10.The strips were evaluated using 233 samples, including sputum, plasma, and pleural effusion samples.The positive detection rates for ICSs for ESAT-6 and CFP-10 in sputum (culture-positive for M tuberculosis) were 100% and 91.2%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in plasma were 34.1% and 29.4%, respectively. The positive detection rates for ICSs for ESAT-6 and CFP-10 in pleural effusion were 64.7% and 55.9%, respectively. Experimental analysis of culture supernatant showing that the ICS developed for ESAT-6 had a sensitivity of 100% and a specificity of 91.2%. While the ICS developed for CFP-10 had a sensitivity of 91.2% and a specificity of 88.2%.The validity of the test is limited by source of sample. The technique is sensitive and specific for samples in sputum and culture media but not for plasma or pleural effusion samples. Detection of M tuberculosis using ICSs is rapid, simple, and relatively effective; thus, ICSs are a potential screening tool for TB. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Gaudin, Valérie; Hedou, Celine; Soumet, Christophe; Verdon, Eric
2016-01-01
The Evidence Investigator™ system (Randox, UK) is a biochip and semi-automated system. The microarray kit II (AM II) is capable of detecting several compounds belonging to different families of antibiotics: quinolones, ceftiofur, thiamphenicol, streptomycin, tylosin and tetracyclines. The performance of this innovative system was evaluated for the detection of antibiotic residues in new matrices, in muscle of different animal species and in aquaculture products. The method was validated according to the European Decision No. EC/2002/657 and the European guideline for the validation of screening methods, which represents a complete initial validation. The false-positive rate was equal to 0% in muscle and in aquaculture products. The detection capabilities CCβ for 12 validated antibiotics (enrofloxacin, difloxacin, ceftiofur, desfuroyl ceftiofur cysteine disulfide, thiamphenicol, florfenicol, tylosin, tilmicosin, streptomycin, dihydrostreptomycin, tetracycline, doxycycline) were all lower than the respective maximum residue limits (MRLs) in muscle from different animal origins (bovine, ovine, porcine, poultry). No cross-reactions were observed with other antibiotics, neither with the six detected families nor with other families of antibiotics. The AM II kit could be applied to aquaculture products but with higher detection capabilities from those in muscle. The detection capabilities CCβ in aquaculture products were respectively at 0.25, 0.10 and 0.5 of the respective MRL in aquaculture products for enrofloxacin, tylosin and oxytetracycline. The performance of the AM II kit has been compared with other screening methods and with the performance characteristics previously determined in honey.
Srivastava, A; Tripathi, A K; Pandey, R; Verma, R K; Gupta, M M
2006-10-01
A sensitive and reproducible reversed-phase high-performance liquid chromatography (HPLC) method using photodiode array detection is established for the simultaneous quantitation of important root alkaloids of Rauvolfia serpentina, namely, reserpine, ajmaline, and ajmalicine. A Chromolith Performance RP-18e column (100 x 4.6-mm i.d.) and a binary gradient mobile phase composed of 0.01 M (pH 3.5) phosphate buffer (NaH(2)PO(4)) containing 0.5% glacial acetic acid and acetonitrile are used. Analysis is run at a flow rate of 1.0 mL/min with the detector operated at a wavelength of 254 nm. The calibration curves are linear over a concentration range of 1-20 microg/mL (r = 1.000) for all the alkaloids. The various other aspects of analysis (i.e., peak purity, similarity, recovery, and repeatability) are also validated. For the three components, the recoveries are found to be 98.27%, 97.03%, and 98.38%, respectively. The limits of detection are 6, 4, and 8 microg/mL for ajmaline, ajmalicine, and reserpine, respectively, and the limits of quantitation are 19, 12, and 23 microg/mL for ajmaline, ajmalicine, and reserpine, respectively. The developed method is simple, reproducible, and easy to operate. It is useful for the evaluation of R. serpentina.
Yan, Lizhen; Deng, Biyang; Shen, Caiying; Long, Chanjuan; Deng, Qiufen; Tao, Chunyao
2015-05-22
A new method for selenium speciation in fermented bean curd wastewater and juice was described. This method involved sample extraction with 5-sulfosalicylic acid (SSA)-functionalized silica-coated magnetic nanoparticles (SMNPs), capillary electrophoresis (CE) separation, and online detection with a modified electrothermal atomic absorption spectrometry (ETAAS) system. The modified interface for ETAAS allowed for the introduction of CE effluent directly through the end of the graphite tube. Elimination of the upper injection hole of the graphite tube reduced the loss of the anlayte and enhanced the detection sensitivity. The SSA-SMNPs were synthesized and used to extract trace amounts of selenite [Se(IV)], selenite [Se(VI)], selenomethionine (SeMet), and selenocystine (SeCys2) from dilute samples. The concentration enrichment factors for Se(VI), Se(IV), SeMet, and SeCys2 were 21, 29, 18, and 12, respectively, using the SSA-SMNPs extraction. The limits of detection for Se(VI), Se(IV), SeMet, and SeCys2 were 0.18, 0.17, 0.54, 0.49ngmL(-1), respectively. The RSD values (n=6) of method for intraday were observed between 0.7% and 2.9%. The RSD values of method for interday were less than 3.5%. The linear range of Se(VI) and Se(IV) were in the range of 0.5-200ngmL(-1), and the linear ranges of SeMet and SeCys2 were 2-500 and 2-1000ngmL(-1), respectively. The detection limits of this method were improved by 10 times due to the enrichment by the SSA-SMNP extraction. The contents of Se(VI) and Se(IV) in fermented bean curd wastewater were measured as 3.83 and 2.62ngmL(-1), respectively. The contents of Se(VI), Se(IV), SeMet, and SeCys2 in fermented bean curd juice were determined as 6.39, 4.08, 2.77, and 4.00ngmL(-1), respectively. The recoveries were in the range of 99.14-104.5% and the RSDs (n=6) of recoveries between 0.82% and 3.5%. Copyright © 2015 Elsevier B.V. All rights reserved.
Lin, Li-Rong; Luo, He-Dong; Li, Xiu-Ying; Li, Na; Zhou, Na; Jia, Yu-Zhu; Liu, Yi-Hong; Li, Yao-Qun
2014-01-01
Based on the high solubility efficiency and strong fluorescence response of benzo(a)pyrene (BaP) in dimethyl sulfoxide in combination with the high-performance derivative constant-energy synchronous fluorescence spectroscopic (DCESFS) technique, a simple, sensitive and economic method was developed for the determination of BaP in liquid milk. This method comprises ultrasound-assisted solvent extraction, solvent replacement and DCESFS detection. No saponification or other tedious clean-up procedures were needed. The recoveries of BaP in different milk samples were greater than 82%. Detection limits in full- and low-fat milk were 0.03 and 0.04 μg kg(-1), respectively.
Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis
Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian
2014-01-01
A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 μM for methanol and 0.2 μM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement. PMID:24412899
Bienzymatic biosensor for rapid detection of aspartame by flow injection analysis.
Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian
2014-01-09
A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.
UltraSensitive Mycotoxin Detection by STING Sensors
Actis, Paolo; Jejelowo, Olufisayo; Pourmand, Nader
2010-01-01
Signal Transduction by Ion Nano Gating (STING) technology is a label-free biosensor capable of identifying DNA and proteins. Based on a functionalized quartz nanopipette, the STING sensor includes specific recognition elements for analyte discrimination based on size, shape and charge density. A key feature of this technology is that it doesn't require any nanofabrication facility; each nanopipette can be easily, reproducibly, and inexpensively fabricated and tailored at the bench, thus reducing the cost and the turnaround time. Here, we show that STING sensors are capable of the ultrasensitive detection of HT-2 toxin with a detection limit of 100 fg/ml and compare the STING capabilities with respect to conventional sandwich assay techniques. PMID:20829024
Rizzo, Vittoria; Porta, Camillo; Moroni, Mauro; Scoglio, Enrico; Moratti, Remigio
2002-07-05
A simple, sensitive and accurate method for the estimation of free and total (free plus protein-bound) melatonin (MLT) in human plasma and cerebrospinal fluid (CSF) is described. Via Chem-Elut cartridges, free and total MLT (the latter obtained after a deproteinization step) were quantified in dichloromethane-extracted samples and analyzed in one chromatographic run by high-performance liquid chromatography (HPLC) with fluorimetric detection. The column used was an Extrasil ODS-2 (3 microm, 150 x 4.6 mm I.D.), while the mobile phase consisted of 75 mM sodium acetate-acetonitrile (72:28, v/v) (pH 5.0). Repeatability and reproducibility of the method were 3.24 and 9.4%, respectively. The recovery of melatonin from plasma and CSF was 99.9+/-4.0% for non-deproteinized samples and 93.2+/-4.8% for deproteinized samples. The detection limit of the assay was 0.5 pg/ml. In human plasma, the mean+/-SD concentrations in the darkness period were 23.18+/-7.44 pg/ml for free melatonin and 82.5+/-36.48 pg/ml for total melatonin, while the lowest concentrations detected during daytime were 2.23+/-2.22 and 7.40+/-5.68 pg/ml, respectively. Detection of MLT in CSF was 5.01+/-2.31 and 28.55+/-6.95 pg/ml for the free and total fraction, respectively.
Wu, Junlin; Liu, Xiaoyun; Peng, Yunping
2014-01-01
A quantitative analytical procedure for the determination of ractopamine in pig hair has been developed and validated. The hair samples were washed and incubated at 75°C with isoxuprine and hair extraction buffer. The drug present was quantified using mixed solid-phase extraction and liquid chromatography with tandem mass spectrometric detection. The limit of quantization (LOQ) was 10pg/mg and the intra-day precision at 25pg/mg and 750pg/mg was 0.49% and 2.8% respectively. Inter-day precision was 0.88% and 3.52% at the same concentrations. The hair extraction percentage recovery at 25pg/mg and 50ng/mL was 99.47% and 103.83% respectively. The extraction percentage recovery at 25pg/mg and 50ng/mg was 93.52% and 100.26% respectively. Our results showed that ractopamine residues persist in hair in 24days of withdrawal and also showed the possibility to test ractopamine from pig hair samples. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Schmidt, K. B.; Treu, T.; Bradač, M.; Vulcani, B.; Huang, K.-H.; Hoag, A.; Maseda, M.; Guaita, L.; Pentericci, L.; Brammer, G. B.; Dijkstra, M.; Dressler, A.; Fontana, A.; Henry, A. L.; Jones, T. A.; Mason, C.; Trenti, M.; Wang, X.
2016-02-01
We present a census of Lyα emission at z≳ 7, utilizing deep near-infrared Hubble Space Telescope grism spectroscopy from the first six completed clusters of the Grism Lens-Amplified Survey from Space (GLASS). In 24/159 photometrically selected galaxies we detect emission lines consistent with Lyα in the GLASS spectra. Based on the distribution of signal-to-noise ratios and on simulations, we expect the completeness and the purity of the sample to be 40%-100% and 60%-90%, respectively. For the objects without detected emission lines we show that the observed (not corrected for lensing magnification) 1σ flux limits reach 5 × 10-18 erg s-1 cm-2 per position angle over the full wavelength range of GLASS (0.8-1.7 μm). Based on the conditional probability of Lyα emission measured from the ground at z˜ 7, we would have expected 12-18 Lyα emitters. This is consistent with the number of detections, within the uncertainties, confirming the drop in Lyα emission with respect to z˜ 6. Deeper follow-up spectroscopy, here exemplified by Keck spectroscopy, is necessary to improve our estimates of completeness and purity and to confirm individual candidates as true Lyα emitters. These candidates include a promising source at z = 8.1. The spatial extent of Lyα in a deep stack of the most convincing Lyα emitters with < z> = 7.2 is consistent with that of the rest-frame UV continuum. Extended Lyα emission, if present, has a surface brightness below our detection limit, consistent with the properties of lower-redshift comparison samples. From the stack we estimate upper limits on rest-frame UV emission line ratios and find {f}{{C}{{IV}}}/{f}{Lyα }≲ 0.32 and {f}{{C}{{III}}]}/{f}{Lyα }≲ 0.23, in good agreement with other values published in the literature.
Christophersen, Asbjørg S; Gjerde, Hallvard
2014-01-01
To examine the prevalence of alcohol and drugs in blood samples collected from car and van drivers killed in traffic accidents in Norway during the time period from 2001 to 2010. Blood samples (n = 676, 63% of all killed drivers) were analyzed for alcohol, psychoactive medications, and illicit drugs. The cutoff limits for positive results were set according to the new legislative limits under the Norwegian Road Traffic Act. The results were assessed in relation to sex and age, time of day and day of week, and single- versus multiple-vehicle and all investigated vehicle accidents. Alcohol or one or more drugs was detected in samples from 40.2 percent of all investigated drivers, with 28.7 percent showing blood concentrations of at least 5 times the legislative limits. For the investigated female drivers, the total prevalence was 24.0 percent. Among the single-vehicle accidents, alcohol or drugs was found in 63.8 percent of the cases, with 49.1 percent showing blood concentrations of at least 5 times the legislative limits. Alcohol was detected in 25.3 and 49.1 percent of samples from all investigated drivers and among drivers killed in single-vehicle accidents, respectively. Psychoactive medications were found in 14.4 and 17.7 percent and illicit drugs in 14.1 and 19.2 percent, respectively. The most commonly detected group of medications was benzodiazepines, and amphetamines and tetrahydrocannabinol were the most commonly detected illicit drugs. The prevalence of alcohol alone was highest among drivers under the age of 25, and the combination of alcohol with other drugs was highest among drivers under the age of 35. Drivers between the ages of 25 and 54 showed the highest prevalence of medications and/or illicit drugs without the presence of alcohol. The highest prevalence of alcohol or drugs was found among drivers killed in single-vehicle accidents on weeknights (83.8%) and on weekend nights (89.3%). The findings confirm that a large number of fatally injured drivers, in particular among drivers involved in single-vehicle accidents, had concentrations of alcohol or drugs above the new legislative limits introduced in 2012. In many cases, concentrations of at least 5 times the limits were found. The proportion of drivers killed who tested positive for alcohol or other drugs did not change during the study period; however, the total number of drivers killed per year decreased by about 20 percent. Some changes were also observed with regard to the types of benzodiazepines and amphetamines detected during the 10-year period.
Borling Welin, Jenny; Lyberg, Karin; Passoth, Volkmar; Olstorpe, Matilda
2015-01-01
This study combined moist airtight storage of moist grain with pig feed fermentation. Starter cultures with the potential to facilitate both technologies were added to airtight stored moist crimped cereal grain, and the impact on storage microflora and the quality of feed fermentations generated from the grain was investigated. Four treatments were compared: three based on moist barley, either un-inoculated (M), inoculated with Wickerhamomyces anomalus (W), or inoculated with W. anomalus and LAB starter culture, containing Pediococcus acidilactici DSM 16243, Pediococcus pentosaceus DSM 12834 and Lactobacillus plantarum DSM 12837 (WLAB); and one treatment based on dried barley (D). After 6 weeks of storage, four feed fermentations FM, FW, FWLAB, and FD, were initiated from M, W, WLAB, and D, respectively, by mixing the grain with water to a dry matter content of 30%. Each treatment was fermented in batch initially for 7 days and then kept in a continuous mode by adding new feed daily with 50% back-slop. During the 6 week storage period, the average water activity decreased in M, W and WLAB from 0.96 to 0.85, and cereal pH decreased from approximately 6.0 at harvest to 4.5. Feed fermentation conferred a further pH decrease to 3.8–4.1. In M, W and WLAB, molds and Enterobacteriaceae were mostly below detection limit, whereas both organism groups were detected in D. In fermented feed, Enterobacteriaceae were below detection limit in almost all conditions. Molds were detected in FD, for most of the fermentation time in FM and at some sampling points in FW and FWLAB. Starter organisms, especially W. anomalus and L. plantarum comprised a considerable proportion of the yeast and LAB populations, respectively, in both stored grain and fermented feed. However, autochthonous Pichia kudriavzevii and Kazachstania exigua partially dominated the yeast populations in stored grain and fermented feed, respectively. PMID:25954295
Yang, Yi; Lu, Dan; Yin, Shuo; Yang, Danni; Chen, Yaling; Li, Yongxin; Sun, Chengjun
2018-04-01
An efficient ultrasound-assisted saponification was developed for simultaneous determination of vitamin E isomers in vegetable oil by high-performance liquid chromatography with fluorescence detection. The samples were saponified ultrasonically with potassium hydroxide solution for only 7 min, then the analytes were extracted with ether. Vitamin E isomers were separated on a C 18 column at 25°C with a mobile phase of methanol/acetonitrile (81:19, v/v) at a flow rate of 0.8 mL/min. Fluorescence detection was operated at 290 nm of excitation wavelength and 327 nm of emission wavelength. Under the optimized conditions, good linearities over the range of 0.001-8.00 μg/mL (r > 0.999) were obtained. Mean recoveries of the method were 88.0-106%, with intra- and interday RSDs less than 11.8 and 12.8%, respectively. The detection limits and quantification limits of the method were 0.30-1.8 and 1.0-6.1 μg/kg, respectively. The recoveries of this method were much higher than that of the quick, easy, cheap, effective, rugged, and safe method and direct dilution method, but were similar to those of hot saponification. This proposed method provides reliable, simple, and rapid quantification of vitamin E isomers in vegetable oils. Five kinds of vegetable oils were analyzed, the quantification results were within the ranges reported by other authors. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pharmacokinetics and pharmacodynamics of detomidine following sublingual administration to horses.
Dimaio Knych, Heather K; Stanley, Scott D
2011-10-01
To characterize pharmacokinetics and pharmacodynamics of detomidine gel administered sublingually in accordance with label instructions to establish appropriate withdrawal guidelines for horses before competition. 12 adult racehorses. Horses received a single sublingual administration of 0.04 mg of detomidine/kg. Blood samples were collected before and up to 72 hours after drug administration. Urine samples were collected for 5 days after detomidine administration. Plasma and urine samples were analyzed via liquid chromatography-mass spectrometry, and resulting data were analyzed by use of noncompartmental analysis. Chin-to-ground distance, heart rate and rhythm, glucose concentration, PCV, and plasma protein concentration were also assessed following detomidine administration. Mean ± SD terminal elimination half-life of detomidine was 1.5 ± 1 hours. Metabolite concentrations were below the limit of detection (0.02, 0.1, and 0.5 ng/mL for detomidine, carboxydetomidine, and hydroxydetomidine, respectively) in plasma by 24 hours. Concentrations of detomidine and its metabolites were below the limit of detection (0.05 ng/mL for detomidine and 0.10 ng/mL for carboxydetomidine and hydroxydetomidine) in urine by 3 days. All horses had various degrees of sedation after detomidine administration. Time of onset was ≤ 40 minutes, and duration of sedation was approximately 2 hours. Significant decreases, relative to values at time 0, were detected for chin-to-ground distance and heart rate. There was an increased incidence and exacerbation of preexisting atrioventricular blocks after detomidine administration. A 48-hour and 3-day withdrawal period for detection in plasma and urine samples, respectively, should be adopted for sublingual administration of detomidine gel.
Zhang, Yuehua; Lei, Wu; Xu, Yujuan; Xia, Xifeng; Hao, Qingli
2016-01-01
A novel, simple and selective electrochemical method was investigated for the simultaneous detection of dopamine (DA) and uric acid (UA) on a poly(l-lysine)/graphene oxide (GO) modified glassy carbon electrode (PLL/GO/GCE) by differential pulse voltammetry (DPV). The electrochemically prepared PLL/GO sensory platform toward the oxidation of UA and DA exhibited several advantages, including high effective surface area, more active sites and enhanced electrochemical activity. Compared to the PLL-modified GCE (PLL/GCE), GO-modified GCE and bare GCE, the PLL/GO/GCE exhibited an increase in the anodic potential difference and a remarkable enhancement in the current responses for both UA and DA. For the simultaneous detection of DA and UA, the detection limits of 0.021 and 0.074 μM were obtained, while 0.031 and 0.018 μM were obtained as the detection limits for the selective detection of UA and DA, using DPV in the linear concentration ranges of 0.5 to 20.0 and 0.5 to 35 μM, respectively. In addition, the PLL/GO/GCE demonstrated good reproducibility, long-term stability, excellent selectivity and negligible interference of ascorbic acid (AA). The proposed modified electrode was successfully implemented in the simultaneous detection of DA and UA in human blood serum, urine and dopamine hydrochloride injection with satisfactory results. PMID:28335305
Fucci, Nadia; Gambelunghe, Cristiana; Aroni, Kyriaki; Rossi, Riccardo
2014-12-01
Because levamisole has been increasingly found as a component of illicit drugs, a robust method to detect its presence in hair samples is needed. However, no systematic research on the detection of levamisole in hair samples has been published. The method presented here uses direct immersion solid-phase microextraction coupled with gas chromatography and mass spectrometry (DI-SPME-GC/MS) to detect levamisole and minor cocaine congeners in hair samples using a single-extraction method. Fifty hair samples taken in the last 4 years were obtained from cocaine abusers, along with controls taken from drug-free volunteers. Sampling was performed using direct immersion with a 30-μm polydimethylsiloxane fused silica/stainless steel fiber. Calibration curves were prepared by adding known amounts of analytes and deuterated internal standards to the hair samples taken from drug-free volunteers. This study focused on the adulterant levamisole and some minor cocaine congeners (tropococaine, norcocaine, and cocaethylene). Levamisole was detected in 38% of the hair samples analyzed; its concentration ranged from 0.2 to 0.8 ng/mg. The limit of quantification and limit of detection for levamisole, tropococaine, norcocaine, and cocaine were 0.2 and 0.1 ng/mg, respectively. DI-SPME-GC/MS is a sensitive and specific method to detect the presence of levamisole and cocaine congeners in hair samples.
Uchiho, Yuichi; Goto, Yusuke; Kamahori, Masao; Aota, Toshimichi; Morisaki, Atsuki; Hosen, Yusuke; Koda, Kimiyoshi
2015-12-11
A far-ultraviolet (FUV)-absorbance detector with a transmission flow cell was developed and applied to detect absorbance of sugars and peptides by HPLC. The main inherent limitation of FUV-absorbance detection is the strong absorptions of solvents and atmospheric oxygen in the optical system as well as dissolved oxygen in the solvent. High absorptivity of the solvent and oxygen decreases transmission-light intensity in the flow cell and hinders the absorbance measurement. To solve the above drawbacks, the transmission-light intensity in the flow cell was increased by introducing a new optical system and a nitrogen-purging unit to remove the atmospheric oxygen. The optical system has a photodiode for detecting the reference light at a position of the minus-first-order diffracted light. In addition, acetonitrile and water were selected as usable solvents because of their low absorptivity in the FUV region. As a result of these implementations, the detectable wavelength of the FUV-absorbance detector (with a flow cell having an effective optical path length of 0.5mm) can be extended down to 175nm. Three sugars (glucose, fructose, and sucrose) were successfully detected with the FUV-absorbance detector. These detection results reveal that the absorption peak of sugar in liquid phase lies at around 178nm. The detection limit (S/N=3) in absorbance with a 0.5-mm flow cell at 180nm was 21μAU, which corresponds to 33, 60 and 60μM (198, 360, and 360pmol) for fructose, glucose, and sucrose, respectively. Also, the peptide Met-enkephalin could be detected with a high sensitivity at 190nm. The estimated detection limit (S/N=3) for Met-enkephalin is 29nM (0.29pmol), which is eight times lower than that at 220nm. Copyright © 2015 Elsevier B.V. All rights reserved.
Wilkes, Rebecca P; Lee, Pei-Yu A; Tsai, Yun-Long; Tsai, Chuan-Fu; Chang, Hsiu-Hui; Chang, Hsiao-Fen G; Wang, Hwa-Tang T
2015-08-01
Canine parvovirus type 2 (CPV-2), including subtypes 2a, 2b and 2c, causes an acute enteric disease in both domestic and wild animals. Rapid and sensitive diagnosis aids effective disease management at points of need (PON). A commercially available, field-deployable and user-friendly system, designed with insulated isothermal PCR (iiPCR) technology, displays excellent sensitivity and specificity for nucleic acid detection. An iiPCR method was developed for on-site detection of all circulating CPV-2 strains. Limit of detection was determined using plasmid DNA. CPV-2a, 2b and 2c strains, a feline panleukopenia virus (FPV) strain, and nine canine pathogens were tested to evaluate assay specificity. Reaction sensitivity and performance were compared with an in-house real-time PCR using serial dilutions of a CPV-2b strain and 100 canine fecal clinical samples collected from 2010 to 2014, respectively. The 95% limit of detection of the iiPCR method was 13 copies of standard DNA and detection limits for CPV-2b DNA were equivalent for iiPCR and real-time PCR. The iiPCR reaction detected CPV-2a, 2b and 2c and FPV. Non-targeted pathogens were not detected. Test results of real-time PCR and iiPCR from 99 fecal samples agreed with each other, while one real-time PCR-positive sample tested negative by iiPCR. Therefore, excellent agreement (k = 0.98) with sensitivity of 98.41% and specificity of 100% in detecting CPV-2 in feces was found between the two methods. In conclusion, the iiPCR system has potential to serve as a useful tool for rapid and accurate PON, molecular detection of CPV-2. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Detection of Glutathione by Glutathione-S-Transferase-Nanoconjugate Ensemble Electrochemical Device.
Barman, Ujjwol; Mukhopadhyay, Gargi; Goswami, Namami; Ghosh, Siddhartha Sankar; Paily, Roy P
2017-06-01
This paper reports a novel electrochemical method for detection of Glutathione (GSH) using Glutathione-S-Transferase (GST) - ZnO composite nanoparticles to investigate the prospects of the method for detection of cancer at an early stage. The purified GST enzyme was bound with ZnO nanoparticles by electrostatic interactions and the nanocomposite was dropcast on a silicon dioxide wafer. The GST functionalized deposited layer was then used as a chemiresistive channel to detect conjugation reaction between GSH and 1-Chloro-2, 4-Dinitrobenzene (CDNB). The zeta potential values of the ZnO nanoparticles and the GST were found to be 13.4 mV and-6.21 mV, respectively. Around 73.8% binding was observed between the enzyme and ZnO nanoparticles. I - V analysis of the chemiresistive channel showed an increase in conductivity of the channel due to conjugation reaction between GSH and CDNB as compared with that of GSH or CDNB alone. I - V characterization of the GST functionalized layer was performed at various concentrations of GSH and a sensitivity and limit of detection of 5.68 nA/ [Formula: see text] and 41.9 nM were obtained, respectively. Thus from I - V analysis of the chemiresistivechannel, the detectionand quantification of GSH could be obtained. The kinetic parameters of both GST and nanoconjugate of ZnO nanoparticles andGSTwere determinedwith respect to its substrates, GSH and CDNB, using Michaelis-Mentenmodel. This novel approach of detection of GSH bymeans of ZnO nanoparticle and GST enzyme composite can be further analyzed for in vitro experiments, which will lead us to a new and efficient way of detecting certain types of cancers at an early stage.
Kazemipour, M.; Ansari, M.; Ramezani, H.; Moradalizadeh, M.
2012-01-01
Most cardiovascular diseases need to be treated by more than a simple drug and the use of combination products diminishes noncompliance. Advicor® as a combination product of a vitamin and a fat lowering agent has no monograph in official pharmacopeias for its quality control purposes. In this study, first and third derivative signals for NA and LV quantitation at the two pairs of wavelengths, 261 and 273 nm; 245 and 249 nm were monitored with the addition of standard solutions of NA or LV, respectively. The limits of detection were 0.03 and 0.32 mg/L for LV and NA, respectively. The limits of quantitation were 0.09 and 0.78 mg/L for LV and NA, respectively. RSD% for both interday and intraday precision was lower than 2.6 and 2.7% for LV and NA, respectively. Selectivity of the method was assessed for both degradation products produced in stress conditions and common excipients that may present in the pharmaceutical dosage forms. The recommended procedure was successfully applied to real samples. PMID:23181086
Analysis of acrylamide in food products by in-line preconcentration capillary zone electrophoresis.
Bermudo, Elisabet; Núñez, Oscar; Puignou, Luis; Galceran, Maria Teresa
2006-09-29
Two in-line preconcentration capillary zone electrophoresis (CZE) methods (field amplified sample injection (FASI) and stacking with sample matrix removal (LVSS)) have been evaluated for the analysis of acrylamide (AA) in foodstuffs. To allow the determination of AA by CZE, it was derivatized using 2-mercaptobenzoic acid. For FASI, the optimum conditions were water at pH > or = 10 adjusted with NH3 as sample solvent, 35 s hydrodynamic injection (0.5 psi) of a water plug, 35 s of electrokinetic injection (-10 kV) of the sample, and 6s hydrodynamic injection (0.5 psi) of another water plug to prevent AA removal by EOF. In stacking with sample matrix removal, the reversal time was found to be around 3.3 min. A 40 mM phosphate buffer (pH 8.5) was used as carrier electrolyte for CZE separation in both cases. For both FASI and LVSS methods, linear calibration curves over the range studied (10-1000 microg L(-1) and 25-1000 microg L(-1), respectively), limit of detection (LOD) on standards (1 microg L(-1) for FASI and 7 microg L(-1) for LVSS), limit of detection on samples (3 ng g(-1) for FASI and 20 ng g(-1) for LVSS) and both run-to-run (up to 14% for concentration and 0.8% for time values) and day-to-day precisions (up to 16% and 5% for concentration and time values, respectively) were established. Due to the lower detection limits obtained with the FASI-CZE this method was applied to the analysis of AA in different foodstuffs such as biscuits, cereals, crisp bread, snacks and coffee, and the results were compared with those obtained by LC-MS/MS.
Kumar, Navneet; Sangeetha, D.; Balakrishna, P.
2011-01-01
Background: In pharmaceutical industries, it is very important to remove drug residues from the equipment and areas used. The cleaning procedure must be validated, so special attention must be devoted to the methods used for analysis of trace amounts of drugs. A rapid, sensitive, and specific reverse phase ultra-performance liquid chromatographic (UPLC) method was developed for the quantitative determination of duloxetine in cleaning validation swab samples. Material and Methods: The method was validated using an Acquity UPLC™ HSS T3 (100 × 2.1 mm2) 1.8 μm column with a isocratic mobile phase containing a mixture of 0.01 M potassium dihydrogen orthophosphate, pH adjusted to 3.0 with orthophosphoric acid and acetonitrile (60:40 v/v). The flow rate of the mobile phase was 0.4 ml/min with a column temperature of 40°C and detection wavelength at 230 nm. Cotton swabs, moisten with extraction solution (90% methanol and 10% water), were used to remove any residue of drug from stainless steel, glass and silica surfaces, and give recoveries >80% at four concentration levels. Results: The precision of the results, reported as the relative standard deviation, were below 1.5%. The calibration curve was linear over a concentration range from 0.02 to 5.0 μg/ml with a correlation coefficient of 0.999. The detection limit and quantitation limit were 0.006 and 0.02 μg/ml, respectively. The method was validated over a concentration range of 0.05–5.0 μg/ml. Conclusion: The developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781449
Roohparvar, Rasool; Taher, Mohammad Ali; Mohadesi, Alireza
2008-01-01
For the simultaneous determination of nickel(ll) and copper(ll) in plant samples, a rapid and accurate method was developed. In this method, solid-phase extraction (SPE) and first-order derivative spectrophotometry (FDS) are combined, and the result is coupled with the H-point standard addition method (HPSAM). Compared with normal spectrophotometry, derivative spectrophotometry offers the advantages of increased selectivity and sensitivity. As there is no need for carrying out any pretreatment of the sample, the spectrophotometry method is easy, but because of a high detection limit, it is not so practical. In order to decrease the detection limit, it is suggested to combine spectrophotometry with a preconcentration method such as SPE. In the present work, after separation and preconcentration of Ni(ll) and Cu(ll) on modified clinoptilolite zeolite that is loaded with 2-[1-(2-hydroxy-5-sulforphenyl)-3-phenyl-5-formaza-no]-benzoic acid monosodium salt (zincon) as a selective chromogenic reagent, FDS-HPSAM, which is a simple and selective spectrophotometric method, has been applied for simultaneous determination of these ions. With optimum conditions, the detection limit in original solutions is 0.7 and 0.5 ng/mL, respectively, for nickel and copper. The linear concentration ranges in the proposed method for nickel and copper ions in original solutions are 1.1 to 3.0 x 10(3) and 0.9 to 2.0 x 10(3) ng/mL, respectively. The recommended procedure is applied to successful determination of Cu(ll) and Ni(ll) in standard and real samples.
Mokbel, Haifaa; Al Dine, Enaam Jamal; Elmoll, Ahmad; Liaud, Céline; Millet, Maurice
2016-04-01
An analytical method associating accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) in immersion mode combined with gas chromatography dual electrons capture detectors (SPME-GC-2ECD) has been developed and studied for the simultaneous determination of 19 organochlorine pesticides (OCPs) and 22 polychlorinated biphenyls (PCBs) in air samples (active and XAD-2 passive samplers). Samples were extracted with ASE with acetonitrile using the following conditions: temperature, 150 °C; pressure, 1500 psi; static, 15 min; cycles, 3; purge, 300 s; flush, 100 %. Extracts were reduced to 1 mL, and 500 μL of this extract, filled with deionised water, was subject to SPME extraction. Experimental results indicated that the proposed method attained the best extraction efficiency under the optimised conditions: extraction of PCB-OCP mixture using 100-μm PDMS fibre at 80 °C for 40 min with no addition of salt. The performance of the proposed ASE-SPME-GC-2ECD methodology with respect to linearity, limit of quantification and detection was evaluated by spiking of XAD-2 resin with target compounds. The regression coefficient (R (2)) of most compounds was found to be high of 0.99. limits of detection (LODs) are between 0.02 and 4.90 ng m(-3), and limits of quantification (LOQs) are between 0.05 and 9.12 ng m(-3) and between 0.2 and 49 ng/sampler and 0.52 and 91 ng/sampler, respectively, for XAD-2 passive samplers. Finally, a developed procedure was applied to determine selected PCBs and OCPs in the atmosphere.
Bobbala, Sharan; McDowell, Arlene; Hook, Sarah
2015-01-15
Monophosphoryl lipid A (MPL) and Quil A are two immunological adjuvants commonly used in vaccines. At present no simple, validated methods for the quantification of Quil A and MPL have been previously reported therefore the aim of the current study was to develop a simple, fast and validated method to quantify MPL and Quil A using high performance liquid chromatography evaporative light scattering detection (HPLC-ELSD). The HPLC-ELSD technique was carried out using a ZORBAX Eclipse XDB-C8 column (2.1×50 mm; particle size, 3.5 μm) in an isocratic elution mode at 25 °C. MPL was eluted at a retention time of 1.8 min with methanol-water as the mobile phase and a detector temperature of 75 °C. Quil A was resolved as three peaks with retention times of 4.1, 5.5 and 6.4 min with a detector temperature of 30 °C and with water-acetonitrile and 0.01% formic acid as the mobile phase. The nebulizer pressure and gain were set at 3.5 bar and 10, respectively. Calibration curves plotted for both the adjuvants had an R(2)>0.997. Accuracy, intra- and inter-day precision were within the accepted limits. The limit of detection for MPL and Quil A were calculated as 1.343 and 2.06 μg/mL, respectively. The limit of quantification was 2.445 for MPL and 8.97 μg/mL for Quil A. This analytical method was used to quantify the entrapment and in vitro release of MPL and Quil A in a poly lactic-co-glycolic acid (PLGA) nanoparticle vaccine. Copyright © 2014 Elsevier B.V. All rights reserved.
Sun, Xiange; Li, Bowei; Qi, Anjin; Tian, Chongguo; Han, Jinglong; Shi, Yajun; Lin, Bingcheng; Chen, Lingxin
2018-02-01
In this work, a novel rotational microfluidic paper-based device was developed to improve the accuracy and performance of the multiplexed colorimetric detection by effectively avoiding the diffusion of colorimetric reagent on the detection zone. The integrated paper-based rotational valves were used to control the connection or disconnection between detection zones and fluid channels. Based on the manipulation of the rotational valves, this rotational paper-based device could prevent the random diffusion of colorimetric reagent and reduce the error of quantitative analysis considerably. The multiplexed colorimetric detection of heavy metals Ni(II), Cu(II) and Cr(VI) were implemented on the rotational device and the detection limits could be found to be 4.8, 1.6, and 0.18mg/L, respectively. The developed rotational device showed the great advantage in improving the detection accuracy and was expected to be a low-cost, portable analytical platform for the on-site detection. Copyright © 2017 Elsevier B.V. All rights reserved.
Yaqoob, Mohammad; Asghar, Mohammad; Nabi, Abdul
2015-11-01
A flow-injection (FI) method is reported for the determination of Mn(II), maneb and mancozeb fungicides based on the catalytic effect of Mn(II) on the oxidation of lucigenin and dissolved oxygen in a basic solution. The Tween-20 surfactant has been reported for first time to enhance lucigenin chemiluminescence (CL) intensity in the presence of Mn(II) (53%) and maneb and mancozeb (89%). The calibration graphs were linear in the concentration range of 0.001-1.5 mg L(-1) (R(2) = 0.9982 (n = 11) with a limit of detection (S/N = 3) of 0.1 µg L(-1) for Mn(II) and 0.01-3.0 mg L(-1) [R(2) = 0.9989 and R(2) = 0.9992 (n = 6)] with a limit of detection (S/N =3) of 1.0 µg L(-1) for maneb and mancozeb respectively. Injection throughputs of 90 and 120 h(-1) for Mn(II) and maneb and mancozeb respectively, and relative standard deviations of 1.0-3.4% were obtained in the concentration range studied. The experimental variables, e.g., reagents concentrations, flow rates, sample volume, and photomultiplier tube voltage, were optimized and potential interferences were investigated. The analysis of Mn(II) in river water reference materials (SLRS-4 and SLRS-5) showed good agreement with the certified values incorporating an on-line 8-hydroxyquinoline chelating column in the manifold for removing interfering metal ions. Recoveries for maneb and mancozeb were in the range of 92 ± 5 to 104 ± 3% and 91 ± 2 to 100 ± 4% (n = 3) respectively. The effect of 30 other pesticides (fungicides, herbicides and insecticides) was also examined in the lucigenin-Tween-20 CL system. Copyright © 2015 John Wiley & Sons, Ltd.
Jang, Moonhee; Kim, Jihyun; Han, Inhoi; Yang, Wonkyung
2015-11-10
Lysergic acid diethylamide (LSD) is administered in low dosages, which makes its detection in biological matrices a major challenge in forensic toxicology. In this study, two sensitive and reliable methods based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) were established and validated for the simultaneous determination of LSD and its metabolite, 2-oxo-3-hydroxy-LSD (O-H-LSD), in hair and urine. Target analytes in hair were extracted using methanol at 38°C for 15h and analyzed by LC-MS/MS. For urine sample preparation, liquid-liquid extraction was performed. Limits of detection (LODs) in hair were 0.25pg/mg for LSD and 0.5pg/mg for O-H-LSD. In urine, LODs were 0.01 and 0.025ng/ml for LSD and O-H-LSD, respectively. Method validation results showed good linearity and acceptable precision and accuracy. The developed methods were applied to authentic specimens from two legal cases of LSD ingestion, and allowed identification and quantification of LSD and O-H-LSD in the specimens. In the two cases, LSD concentrations in hair were 1.27 and 0.95pg/mg; O-H-LSD was detected in one case, but its concentration was below the limit of quantification. In urine samples collected from the two suspects 8 and 3h after ingestion, LSD concentrations were 0.48 and 2.70ng/ml, respectively, while O-H-LSD concentrations were 4.19 and 25.2ng/ml, respectively. These methods can be used for documenting LSD intake in clinical and forensic settings. Copyright © 2015 Elsevier B.V. All rights reserved.
Feddern, Vivian; Aroeira, Carolina Naves; Molognoni, Luciano; Gressler, Vanessa; Daguer, Heitor; Dalla Costa, Osmar Antonio; Castillo, Carmen Josefina Contreras; de Lima, Gustavo Julio Mello Monteiro
2018-05-23
Ractopamine has been allowed by some countries as a repartitioning additive in pig diet, since it promotes protein synthesis and fat lipolysis. Most regulatory agencies only propose the ractopamine assessment in meat, kidney, liver and fat. Aiming at contributing to the scarcity data regarding this analyte in pig lungs, we extended the scope of a LC-MS method to evaluate pig offals. Homogenized tissue samples were extracted by a QuEChERS procedure; following by clean up steps and further tandem mass spectrometry determination. Method performance was evaluated through specificity, recovery, linearity, reproducibility, repeatability, decision limit (CC α ), and detection capability (CC β ), in accordance to the Commission Decision 2002/657/EC. Regression coefficients (R 2 ) between 0.994 and 0.999 were achieved for kidney, liver and lungs. Recoveries ranged from 92.0 to 127%. CC α and CC β values ranged from 3.65 to 4.86 μg kg -1 , and from 6.27 to 7.21 μg kg -1 , respectively. These values were under the maximum residue limits suggested by Codex Alimentarius, which are 90 and 40 μg kg -1 for kidney and liver, respectively. When applied to real samples up to 22.5, 92 and 1003 μg kg -1 of ractopamine residues were detected in pig liver, kidney and lungs, respectively. The results allowed concluding that the proposed analytical method is capable to detect ractopamine residues in all evaluated matrices. Therefore, it can be successfully applied and used as a routine method in laboratories of residue analysis. Copyright © 2018. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Cao, Yupin; Yan, Lizhen; Huang, Hongli; Deng, Biyang
2016-08-01
A new method for determination of selenium species in radix puerariae was described. The method consists of sample enrichment with 5-sulfosalicylic acid (SSA)-functionalized silica-coated magnetic nanoparticles (SMNPs), high performance liquid chromatography (HPLC) separation, and online detection using inductively coupled plasma mass spectrometry (ICP-MS). The selenium species were extracted using ultrasonic extraction system with a mixture of protease K and lipase. The SSA-SMNPs were used to enrich trace amounts of selenite [Se(IV)], selenate [Se(VI)], selenomethionine (SeMet), and selenocystine (SeCys2) from lower selenium containing samples. Under the optimal conditions, the limits of detection (3σ) for SeCys2, Se(IV), SeMet and Se(VI) were observed as 0.0023, 0.0015, 0.0043, and 0.0016 ng mL- 1, respectively. The RSD values (n = 6) of method for intraday were observed between 0.5% and 0.9%. The RSD values of method for interday were less than 1.3%. The linear concentration ranges for SeCys2, Se(IV), SeMet and Se(VI) were 0.008-1000, 0.005-200, 0.015-500 and 0.006-200 ng mL- 1, respectively. The detection limits of this method were improved by 10 times due to the enrichment with the SSA-SMNP extraction. The contents of SeCys2, Se(IV), SeMet, and Se(VI) in radix puerariae were determined as 0.0140, 0.171, 0.0178, and 0.0344 μg g- 1, respectively. The recoveries were in the range of 95.6%-99.4% and the RSDs (n = 6) of recoveries were less than 1.5%.
NASA Astrophysics Data System (ADS)
Peng, Yahui; Ma, Xiao; Gao, Xinyu; Zhou, Fangxu
2015-12-01
Computer vision is an important tool for sports video processing. However, its application in badminton match analysis is very limited. In this study, we proposed a straightforward but robust histogram-based background estimation and player detection methods for badminton video clips, and compared the results with the naive averaging method and the mixture of Gaussians methods, respectively. The proposed method yielded better background estimation results than the naive averaging method and more accurate player detection results than the mixture of Gaussians player detection method. The preliminary results indicated that the proposed histogram-based method could estimate the background and extract the players accurately. We conclude that the proposed method can be used for badminton player tracking and further studies are warranted for automated match analysis.
Multistatic GNSS Receiver Array for Passive Air Surveillance
NASA Astrophysics Data System (ADS)
Wachtl, Stefan; Koch, Volker; Westphal, Robert; Schmidt, Lorenz-Peter
2016-03-01
The performance of a passive air surveillance sensor based on Global Navigation Satellite Systems (GNSS) is mainly limited by the receiver noise efficiency, the achievable signal processing gain and the radar cross section (RCS) of an airplane. For surveillance applications large detection ranges as well as a high probability of detection are crucial parameters. Due to the very low GNSS signal powers received on the earth's surface, high radar cross sections are mandatory to achieve detection ranges for airplanes at some kilometers distance. This paper will discuss a multistatic transmitter and receiver arrangement, which is indispensable to get a reasonable detection rate with respect to a hemispheric field of view. The strong performance dependency of such a sensor on the number of transmitters and receivers will be shown by means of some exemplary simulation results.
Copernicus observational searches for OH and H2O in diffuse clouds
NASA Technical Reports Server (NTRS)
Smith, W. H.; Snow, T. P., Jr.
1983-01-01
An intensive search for OH and H2O in the directions of sigma Sco, alpha Cam, and micron Per was undertaken with the Copernicus satellite. Multiple scans were carried out over the wavelength region for the expected absorption features due to the OH D-X and H2O C-X transitions. The feature due to OH was detected marginally towards sigma Sco, and only an upper limit can be given towards alpha Cam. H2O was not detected in any of the stars at the signal level accumulated. The OH abundance towards sigma Sco and the respective lower limits for the OH/H2O ratios are discussed with regard to the extant models for the steady state abundances of OH and H2O, and shown not to be inconsistent with ion-molecule schemes.
Copernicus observational searches for OH and H2O in diffuse clouds
NASA Technical Reports Server (NTRS)
Smith, W. H.; Snow, T. P., Jr.
1979-01-01
An intensive search for OH and H2O in the directions of Sigma Sco, Alpha Cam, and Omicron Per was undertaken with the Copernicus satellite. Multiple scans were carried out over the wavelength region for the expected absorption features due to the OH D-X and H2O C-X transitions. The feature due to OH was possibly detected toward Sigma Sco, and only an upper limit can be given toward Alpha Cam. H2O was not detected in any of the stars at the signal level accumulated. The OH abundance toward Sigma Sco and the respective lower limits for the OH/H2O ratios are discussed with regard to the extant models for the steady-state abundances of OH and H2O, and shown not to be inconsistent with ion-molecule schemes.
Trace Level Determination of Polyether Ionophores in Feed
Rokka, Mervi; Jestoi, Marika; Peltonen, Kimmo
2013-01-01
A liquid chromatography-mass spectrometric method was developed and validated to determine six polyether ionophores (lasalocid sodium, monensin sodium, salinomycin sodium, narasin, maduramicin ammonium alpha, and semduramicin sodium) in feed samples. The method developed was very straightforward, involving extraction with 84% acetonitrile of the coccidiostats from the feed samples and filtration of the raw extract prior to chromatographic analysis. Method validation included the determination of selectivity, linearity, specificity, repeatability, the limit of detection, limit of quantification, decision limit (CCα), detection capability (CCβ), and recovery. Feed samples from the Finnish national feed control programme and suspected carry-over samples from a feed manufacturer were analysed in parallel with an existing liquid chromatography method coupled with ultraviolet detection. All feed control samples were negative in LC-UV, but with the developed MS method, monensin, salinomycin, and narasin were detected at concentrations of <0.025–0.73 mg/kg, <0.025–0.027 mg/kg, and <0.025–1.6 mg/kg, respectively. In suspected carry-over samples after an output of 2.0 tonnes of unmedicated feed in the pelletizer line, the concentrations of monensin, salinomycin, and narasin varied from undetected to 16 mg/kg. In the mixer line, after 3.2 tonnes of unmedicated feed output, the concentrations of monensin, salinomycin, and narasin varied from undetected to 2.4 mg/kg. PMID:23484082
Zahl Eriksson, Ane Gerda; Ducie, Jen; Ali, Narisha; McGree, Michaela E; Weaver, Amy L; Bogani, Giorgio; Cliby, William A; Dowdy, Sean C; Bakkum-Gamez, Jamie N; Abu-Rustum, Nadeem R; Mariani, Andrea; Leitao, Mario M
2016-03-01
To assess clinicopathologic outcomes between two nodal assessment approaches in patients with endometrioid endometrial carcinoma and limited myoinvasion. Patients with endometrial cancer at two institutions were reviewed. At one institution, a complete pelvic and para-aortic lymphadenectomy to the renal veins was performed in select cases deemed at risk for nodal metastasis due to grade 3 cancer and/or primary tumor diameter>2cm (LND cohort). This is a historic approach at this institution. At the other institution, a sentinel lymph node mapping algorithm was used per institutional protocol (SLN cohort). Low risk was defined as endometrioid adenocarcinoma with myometrial invasion <50%. Macrometastasis, micrometastasis, and isolated tumor cells were all considered node-positive. Of 1135 cases identified, 642 (57%) were managed with an SLN approach and 493 (43%) with an LND approach. Pelvic nodes (PLNs) were removed in 93% and 58% of patients, respectively (P<0.001); para-aortic nodes (PANs) were removed in 14.5% and 50% of patients, respectively (P<0.001). Median number of PLNs removed was 6 and 34, respectively; median number of PANs removed was 5 and 16, respectively (both P<0.001). Metastasis to PLNs was detected in 5.1% and 2.6% of patients, respectively (P=0.03), and to PANs in 0.8% and 1.0%, respectively (P=0.75). The 3-year disease-free survival rates were 94.9% (95% CI, 92.4-97.5) and 96.8% (95% CI, 95.2-98.5), respectively. Our findings support the use of either strategy for endometrial cancer staging, with no apparent detriment in adhering to the SLN algorithm. The clinical significance of disease detected on ultrastaging and the role of adjuvant therapy is yet to be determined. Copyright © 2016 Elsevier Inc. All rights reserved.
Eriksson, Ane Gerda Zahl; Ducie, Jen; Ali, Narisha; McGree, Michaela E.; Weaver, Amy L.; Bogani, Giorgio; Cliby, William A.; Dowdy, Sean C.; Bakkum-Gamez, Jamie N.; Abu-Rustum, Nadeem R.; Mariani, Andrea; Leitao, Mario M.
2016-01-01
Objectives To assess clinicopathologic outcomes between two nodal assessment approaches in patients with endometrioid endometrial carcinoma and limited myoinvasion. Methods Patients with endometrial cancer at two institutions were reviewed. At one institution, a complete pelvic and para-aortic lymphadenectomy to the renal veins was performed in select cases deemed at risk for nodal metastasis due to grade 3 cancer and/or primary tumor diameter >2 cm (LND cohort). This is a historic approach at this institution. At the other institution, a sentinel lymph node mapping algorithm was used per institutional protocol (SLN cohort). Low risk was defined as endometrioid adenocarcinoma with myometrial invasion <50%. Macrometastasis, micrometastasis, and isolated tumor cells were all considered node-positive. Results Of 1135 cases identified, 642 (57%) were managed with an SLN approach and 493 (43%) with an LND approach. Pelvic nodes (PLNs) were removed in 93% and 58% of patients, respectively (P<0.001); para-aortic nodes (PANs) were removed in 14.5% and 50% of patients, respectively (P<0.001). Median number of PLNs removed was 6 and 34, respectively; median number of PANs removed was 5 and 16, respectively (both P<0.001). Metastasis to PLNs was detected in 5.1% and 2.6% of patients, respectively (P=0.03), and to PANs in 0.8% and 1.0%, respectively (P=0.75). The 3-year disease-free survival rates were 94.9% (95%CI, 92.4–97.5) and 96.8% (95%CI, 95.2–98.5), respectively. Conclusions Our findings support the use of either strategy for endometrial cancer staging, with no apparent detriment to the SLN algorithm. The clinical significance of disease detected on ultrastaging and the role of adjuvant therapy is yet to be determined. PMID:26747778
Nanocomposite polymer structures for optical sensors of hydrogen sulfide
NASA Astrophysics Data System (ADS)
Sergeev, A. A.; Mironenko, A. Yu.; Nazirov, A. E.; Leonov, A. A.; Voznesenskii, S. S.
2017-08-01
Composite coatings based on gold and silver nanoparticles reduced in situ in the film of chitosan polysaccharide are studied. In the presence of hydrogen sulfide, the maximum of plasmon resonance of the nanoparticles that is proportional to the analyte concentration decreases. The detection limits for hydrogen sulfide are 0.1 and 5 ppm for the chitosan/silver and chitosan/gold nanocomposites, respectively.
Singh, C L; Singh, A; Kumar, S; Kumar, M; Sharma, P K; Majumdar, D K
2015-01-01
In the present study a simple, accurate, precise, economical and specific UV-spectrophotometric method for estimation of besifloxacin in bulk and in different pharmaceutical formulation has been developed. The drug shows maximum λmax289 nm in distilled water, simulated tears and phosphate buffer saline. The linearity range of developed methods were in the range of 3-30 μg/ml of drug with a correlation coefficient (r(2)) 0.9992, 0.9989 and 0.9984 with respect to distilled water, simulated tears and phosphate buffer saline, respectively. Reproducibility by repeating methods as %RSD were found to be less than 2%. The limit of detection in different media was found to be 0.62, 0.72 and 0.88 μg/ml, respectively. The limit of quantification was found to be 1.88, 2.10, 2.60 μg/ml, respectively. The proposed method was validated statically according to International Conference on Harmonization guidelines with respect to specificity, linearity, range, accuracy, precision and robustness. The proposed methods of validation were found to be accurate and highly specific for the estimation of besifloxacin in different pharmaceutical formulations.
Attia, M S; Ramsis, M N; Khalil, L H; Hashem, S G
2012-03-01
A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of trace amounts of chlorzoxazone and Ibuprofen in pharmaceutical tablets using optical sensor Eu-Tetracycline HCl doped in sol-gel matrix. The chlorzoxazone or Ibuprofen can remarkably enhance the luminescence intensity of Eu-Tetracycline HCl complex doped in a sol-gel matrix in dimethylformamide (DMF) at pH 9.7 and 6.3, respectively, λ(ex) = 400 nm. The enhancing of luminescence intensity peak of Eu-Tetracycline HCl complex at 617 nm is proportional to the concentration of chlorzoxazone or Ibuprofen a result that suggested profitable application as a simple optical sensor for chlorzoxazone or Ibuprofen assessment. The dynamic ranges found for the determination of chlorzoxazone and Ibuprofen concentration are 5 × 10(-9)-1 × 10(-4) and 1 × 10(-8)-7 × 10(-5) mol L(-1), and the limit of detection (LOD) and quantitation limit of detection (LOQ) are 3.1 × 10(-10), 9.6 × 10(-10) and 5.6 × 10(-10), 1.7 × 10(-9) mol L(-1), respectively.
Aflatoxin M₁ in raw milk from different regions of São Paulo state--Brazil.
Santili, Ana Beatriz Nappi; de Camargo, Adriano Costa; Nunes, Raquel de Syllos Rosa; da Gloria, Eduardo Micotti; Machado, Paulo Fernando; Cassoli, Laerte Dagher; Dias, Carlos Tadeu dos Santos; Calori-Domingues, Maria Antonia
2015-01-01
A total of 635 raw milk samples from 45 dairy farms, from three regions of São Paulo state - Brazil, were evaluated during 15 months for aflatoxin M1 (AFM1). AFM1 was determined by high performance liquid chromatograph with fluorescence detection. AFM1 was detected (>0.003 µg kg(-1)) in 72.9%, 56.3% and 27.5% of the samples from Bauru, Araçatuba and Vale do Paraíba regions, respectively. The mean AFM1 contamination considering all the samples was 0.021 µg kg(-1). Furthermore, the concentration of AFM1 was quite different among Bauru (0.038 µg kg(-1)), Araçatuba (0.017 µg kg(-1)) and Vale do Paraíba (<0.01 µg kg(-1)) regions. Only three samples (0.5%) had higher contamination than the tolerated limit in Brazil (0.50 µg kg(-1)) and 64 samples (10.1%) had a higher contamination than the maximum limit as set by the European Union (0.050 µg kg(-1)). The estimated AFM1 daily intake was 0.358 and 0.120 ng kg(-1) body weight per day for children and adults, respectively.
Sánchez, G; Elizaquível, P; Aznar, R
2012-01-03
Fresh-cut vegetables are prone to be contaminated with foodborne pathogens during growth, harvest, transport and further processing and handling. As most of these products are generally eaten raw or mildly treated, there is an increase in the number of outbreaks caused by viruses and bacteria associated with fresh vegetables. Foodborne pathogens are usually present at very low levels and have to be concentrated (i.e. viruses) or enriched (i.e. bacteria) to enhance their detection. With this aim, a rapid concentration method has been developed for the simultaneous recovery of hepatitis A virus (HAV), norovirus (NV), murine norovirus (MNV) as a surrogate for NV, Escherichia coli O157:H7, Listeria monocytogenes and Salmonella enterica. Initial experiments focused on evaluating the elution conditions suitable for virus release from vegetables. Finally, elution with buffered peptone water (BPW), using a Pulsifier, and concentration by polyethylene glycol (PEG) precipitation were the methods selected for the elution and concentration of both, enteric viruses and bacteria, from three different types of fresh-cut vegetables by quantitative PCR (qPCR) using specific primers. The average recoveries from inoculated parsley, spinach and salad, were ca. 9.2%, 43.5%, and 20.7% for NV, MNV, and HAV, respectively. Detection limits were 132 RT-PCR units (PCRU), 1.5 50% tissue culture infectious dose (TCID₅₀), and 6.6 TCID₅₀ for NV, MNV, and HAV, respectively. This protocol resulted in average recoveries of 57.4%, 64.5% and 64.6% in three vegetables for E. coli O157:H7, L. monocytogenes and Salmonella with corresponding detection limits of 10³, 10² and 10³ CFU/g, respectively. Based on these results, it can be concluded that the procedure herein is suitable to recover, detect and quantify enteric viruses and foodborne pathogenic bacteria within 5 h and can be applied for the simultaneous detection of both types of foodborne pathogens in fresh-cut vegetables. Copyright © 2011 Elsevier B.V. All rights reserved.
Naksen, Warangkana; Prapamontol, Tippawan; Mangklabruks, Ampica; Chantara, Somporn; Thavornyutikarn, Prasak; Robson, Mark G.; Ryan, P. Barry; Barr, Dana Boyd; Panuwet, Parinya
2016-01-01
Organophosphate (OP) pesticides are widely used for crop protection in many countries including Thailand. Aside from causing environmental contamination, they affect human health especially by over-stimulating of the neurotransmission system. OP pesticides, as with other non-persistent pesticides, degrade quickly in the environment as well as are metabolized quite rapidly in humans. Assessing human exposures to these compounds requires analytical methods that are sensitive, robust, and most importantly, suitable for specific laboratory settings. The aim of this study was to develop and validate an analytical method for measuring 11 OP pesticide residues in human plasma and breast milk. Analytes in both plasma and breast milk samples were extracted with acetone and methylene chloride, cleaned-up using aminopropyl solid phase extraction cartridges, and analyzed by gas chromatography with flame photometric detection. The optimized method exhibited good linearity, with the coefficients of determination of 0.996–0.999 and <7% error about the slope. Extraction recoveries from spiked plasma and breast milk samples at low and medium concentrations (0.8–5.0 and 1.6–10 ng mL−1, respectively) ranged from 59.4 % (ethion) to 94.0 % (chlorpyrifos). Intra-batch and inter-batch precisions ranged from 2.3–18.9% and 5.8–19.5%, respectively. Method detection limits of plasma and breast milk ranged from 0.18–1.36 and 0.09–2.66 ng mL−1, respectively. We analyzed 63 plasma and 30 breastmilk samples collected from farmworkers in Chiang Mai Province to determine the suitability of this method for occupational exposure assessment. Of the 11 pesticides measured, seven were detected in plasma samples and five were detected in breast milk samples. Mass spectrometry was used to confirm results. Overall, this method is rapid and reliable. It offers the laboratories with limited access to mass spectrometry a capacity to investigate levels OP pesticides in plasma and breastmilk in those occupationally exposed for health risk assessment. PMID:27232054
RAHIMIRAD, Amir; MAALEKINEJAD, Hassan; OSTADI, Araz; YEGANEH, Samal; FAHIMI, Samira
2014-01-01
Abstract Background Aflatoxin M1 (AFM1), a carcinogenic substance is found in milk and dairy products. The effect of season and type of dairy products on AFMi level in northern Iran was investigated in this study. Methods Three hundred samples (each season 75 samples) including raw and pasteurized milk, yoghurt, cheese, and cream samples were collected from three distinct milk producing farms. The samples were subjected to chemical and solid phase extractions and were analyzed by using HPLC technique. Recovery percentages, limit of detection and limit of quantification values were determined. Results Seventy percent and 98% were the minimum and maximum recoveries for cheese and raw milk, respectively and 0.021 and 0.063 ppb were the limit of detection and limit of quantification values for AFM1. We found that in autumn and winter the highest level (0.121 ppb) of AFM1 in cheese and cream samples and failed to detect any AFM1 in spring samples. Interestingly, our data showed that the yoghurt samples had the lowest level of AFM1 in all seasons. Conclusion There are significant differences between the AFM1 levels in dairy products in various seasons and also various types of products, suggesting spring and summer yoghurt samples as the safest products from AFM1 level point of view. PMID:25927044
Lehel, József; Zwillinger, Dóra; Bartha, András; Lányi, Katalin; Laczay, Péter
2017-11-01
The muscle, liver, kidney and fat samples of 20 roe deer of both sexes originating from a hunting area in central Hungary were investigated for the presence of heavy metals such as As, Cd, Hg and Pb, and their contents were evaluated for possible health risk to consumers. Both As and Hg were found at a level below the limit of detection (< 0.5 mg/kg wet weight) in all samples. The median of the measured Cd concentrations was significantly higher in both the kidney and the liver (p = 0.0011) of bucks than of does. In bucks, Cd levels exceeded the respective maximum limits laid down in the European legislation in four kidney and three muscle samples, whereas in does, the measured concentrations were below the respective limits in all samples. The detected amounts of Pb exceeded the maximum limits in the kidney of one buck and eight does, in the liver of two bucks and six does, in the muscle of six bucks and nine does, whereas in all fat tissues of both bucks and does. The concentration of Pb (p = 0.02) was significantly greater in the kidney of does compared to roebucks. Based on data obtained from the present study, the consumption of organs and tissues of the investigated roe deer could be objectionable from food-toxicological point of view and may pose risk to the high consumers of wild game due to their cadmium and lead contents.
Da Rin, G; Vidali, M; Balboni, F; Benegiamo, A; Borin, M; Ciardelli, M L; Dima, F; Di Fabio, A; Fanelli, A; Fiorini, F; Francione, S; Germagnoli, L; Gioia, M; Lari, T; Lorubbio, M; Marini, A; Papa, A; Seghezzi, M; Solarino, L; Pipitone, S; Tilocca, E; Buoro, S
2017-12-01
Recent automated hematology analyzers (HAs) can identify and report nucleated red blood cells (NRBC) count as a separate population out of white blood cells (WBC). The aim of this study was to investigate the analytical performances of NRBC enumeration on five top of the range HAs. We evaluated the within-run and between-day precision, limit of blank (LoB), limit of detection (LoD), and limit of quantitation (LoQ) of XE-2100 and XN-module (Sysmex), ADVIA 2120i (Siemens), BC-6800 (Mindray), and UniCel DxH 800 (Beckman Coulter). Automated NRBC counts were also compared with optical microscopy (OM). The limits of detection for NRBC of the BC-6800, XN-module, XE-2100, UniCel DxH 800, and ADVIA 2120i are 0.035×10 9 /L, 0.019×10 9 /L, 0.067×10 9 /L, 0.038×10 9 /L, and 0.167×10 9 /L, respectively. Our data indicated excellent performance in terms of precision. The agreement with OM was excellent for BC-6800, XN-module, and XE-2100 (Bias 0.023, 0.019, and 0.033×10 9 /L, respectively). ADVIA 2120i displayed a significant constant error and UniCel DxH 800 both proportional and small constant error. Regards to NRBC counting, the performances shown by BC-6800, XN-module, and XE-2100 are excellent also a low count, ADVIA 2120i and UniCel DxH 800 need to be improved. © 2017 John Wiley & Sons Ltd.
Nazaripour, Ali; Yamini, Yadollah; Ebrahimpour, Behnam; Fasihi, Javad
2016-07-01
In this study, two-phase hollow-fiber liquid-phase microextraction and three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents were compared for extraction of oxazepam and Lorazepam. Separations were performed on a liquid chromatography with mass spectrometry instrument. Under optimal conditions, three-phase hollow-fiber liquid-phase microextraction based on two immiscible organic solvents has a better extraction efficiency. In a urine sample, for three-phase hollow fiber liquid-phase microextraction based on two immiscible organic solvents, the calibration curves were found to be linear in the range of 0.6-200 and 0.9-200 μg L(-1) and the limits of detection were 0.2 and 0.3 μg L(-1) for oxazepam and lorazepam, respectively. For two-phase hollow fiber liquid-phase microextraction, the calibration curves were found to be linear in the range of 1-200 and 1.5-200 μg L(-1) and the limits of detection were 0.3 and 0.5 μg L(-1) for oxazepam and lorazepam, respectively. In a urine sample, for three-phase hollow-fiber-based liquid-phase microextraction based on two immiscible organic solvents, relative standard deviations in the range of 4.2-4.5% and preconcentration factors in the range of 70-180 were obtained for oxazepam and lorazepam, respectively. Also for the two-phase hollow-fiber liquid-phase microextraction, preconcentration factors in the range of 101-257 were obtained for oxazepam and lorazepam, respectively. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liang, Xiaohui; Fang, Xiangyi; Yao, Manwen; Yang, Yucong; Li, Junfeng; Liu, Hongjun; Wang, Linyu
2016-02-01
Direct competitive chemiluminescence immunoassays (CLIA) based on gold-coated magnetic nanospheres (Au-MNPs) were developed for rapid analysis of chloramphenicol (CAP). The Au-MNPs were modified with carboxyl groups and amino groups by 11-mercaptoundecanoic acid (MUA) and cysteamine respectively, and then were respectively conjugated with CAP base and CAP succinate via an activating reaction using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS). NSP-DMAE-NHS, a new and effective luminescence reagent, was employed to label anti-CAP antibody (mAb) as a tracer in direct CLIA for CAP detection using a 'homemade' luminescent measurement system that was set up with a photomultiplier tube (PMT) and a photon counting unit linked to a computer. The sensitivities and limits of detection (LODs) of the two methods were obtained and compared according to the inhibition curves. The 50% inhibition concentration (IC50 ) values of the two methods were about 0.044 ng/mL and 0.072 ng/mL respectively and LODs were approximately 0.001 ng/mL and 0.006 ng/mL respectively. To our knowledge, they were much more sensitive than any traditional enzyme-linked immunosorbent assay (ELISA) ever reported. Moreover, the new luminescence reagent NSP-DMAE-NHS is much more sensitive and stable than luminol and its derivatives, contributing to the sensitivity enhancement. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Shaltout, Abdallah A.; Hassan, Salwa K.; Karydas, Andreas G.; Zaki, Z. I.; Mostafa, Nasser Y.; Kregsamer, Peter; Wobrauschek, Peter; Streli, Christina
2018-07-01
Fine aerosol particles with aerodynamic diameter equal or <2.5 μm (PM2.5) have been collected from industrial and residential areas of Greater Cairo, Egypt during two different seasons namely; autumn 2014 and winter 2014/2015. Energy dispersive X-ray fluorescence (EDXRF) analysis utilizing polarization geometry and three different secondary targets (CaF2, Ge, and Mo) was employed for the quantitative analysis of eighteen (18) elements in PM2.5 samples. Light elements like Na and Mg was possible to be quantified, whereas detection limits in the range of few ng m-3 were attained for the most of the detected elements. Although, the average mass concentrations of the PM2.5 collected from the residential area (27 ± 7 μg m-3) is close to the annual mean limit value, a significant number of the collected samples (33%) presented higher average mass concentrations. For the industrial location, the average mass concentration is equal to 55 ± 19 μg m-3, exceeded twofold the annual mean limit value of the European Commission. Remarkably high elemental concentrations were determined for the most of the detected elements from the industrial area samples, clearly indicating the significant influence of anthropogenic activities. The present optimized EDXRF analysis offered significantly improved analytical range and limits of detection with respect to previous similar studies, thus enhancing our knowledge and understanding on the contribution of different pollution sources.
2012-01-01
Background Gametocyte carriage is essential for malaria transmission and endemicity of disease; thereby it is a target for malaria control strategies. Malaria-infected individuals may harbour gametocytes below the microscopic detection threshold that can be detected by reverse transcription polymerase chain reaction (RT-PCR) targeting gametocyte-specific mRNA. To date, RT-PCR has mainly been applied to the diagnosis of Plasmodium falciparum gametocytes but very limited for that of Plasmodium vivax. Methods A multiplex-nested RT-PCR targeting Pfs25 and Pvs25 mRNA specific to mature gametocytes of P. falciparum and P. vivax, respectively, was developed. The assay was evaluated using blood samples collected in rainy and dry seasons from febrile patients,in a malaria-endemic area in Thailand. Malaria diagnosis was performed by Giemsa-stained blood smears and 18S rRNA PCR. Results The multiplex-nested RT-PCR detected Pfs25 mRNA in 75 of 86 (87.2%) P. falciparum-infected individuals and Pvs25 mRNA in 82 of 90 (91.1%) P. vivax malaria patients diagnosed by 18S rRNA PCR. Gametocytes were detected in 38 (eight P. falciparum and 30 P. vivax) of 157 microscopy positive samples, implying that a large number of patients harbour sub-microscopic gametocytaemia. No seasonal differences in gametocyte carriage were observed for both malaria species diagnosed by multiplex-nested RT-PCR. With single-nested RT-PCR targeting Pfs25 or Pvs25 mRNA as standard, the multiplex-nested RT-PCR offered sensitivities of 97.4% and 98.9% and specificities of 100% and 98.8% for diagnosing mature gametocytes of P. falciparum and P. vivax, respectively. The minimum detection limit of the multiplex-nested PCR was 10 copies of templates. Conclusions The multiplex-nested RT-PCR developed herein is useful for simultaneous assessment of both P. falciparum and P. vivax gametocyte carriage that is prevalent and generally sympatric in several malaria-endemic areas outside Africa. PMID:22682065
Kuamsab, Napaporn; Putaporntip, Chaturong; Pattanawong, Urassaya; Jongwutiwes, Somchai
2012-06-10
Gametocyte carriage is essential for malaria transmission and endemicity of disease; thereby it is a target for malaria control strategies. Malaria-infected individuals may harbour gametocytes below the microscopic detection threshold that can be detected by reverse transcription polymerase chain reaction (RT-PCR) targeting gametocyte-specific mRNA. To date, RT-PCR has mainly been applied to the diagnosis of Plasmodium falciparum gametocytes but very limited for that of Plasmodium vivax. A multiplex-nested RT-PCR targeting Pfs25 and Pvs25 mRNA specific to mature gametocytes of P. falciparum and P. vivax, respectively, was developed. The assay was evaluated using blood samples collected in rainy and dry seasons from febrile patients,in a malaria-endemic area in Thailand. Malaria diagnosis was performed by Giemsa-stained blood smears and 18S rRNA PCR. The multiplex-nested RT-PCR detected Pfs25 mRNA in 75 of 86 (87.2%) P. falciparum-infected individuals and Pvs25 mRNA in 82 of 90 (91.1%) P. vivax malaria patients diagnosed by 18S rRNA PCR. Gametocytes were detected in 38 (eight P. falciparum and 30 P. vivax) of 157 microscopy positive samples, implying that a large number of patients harbour sub-microscopic gametocytaemia. No seasonal differences in gametocyte carriage were observed for both malaria species diagnosed by multiplex-nested RT-PCR. With single-nested RT-PCR targeting Pfs25 or Pvs25 mRNA as standard, the multiplex-nested RT-PCR offered sensitivities of 97.4% and 98.9% and specificities of 100% and 98.8% for diagnosing mature gametocytes of P. falciparum and P. vivax, respectively. The minimum detection limit of the multiplex-nested PCR was 10 copies of templates. The multiplex-nested RT-PCR developed herein is useful for simultaneous assessment of both P. falciparum and P. vivax gametocyte carriage that is prevalent and generally sympatric in several malaria-endemic areas outside Africa.
Zhou, Baoqing; Chen, Bolu; Wu, Xin; Li, Fan; Yu, Pei; Aguilar, Zoraida P; Wei, Hua; Xu, Hengyi
2016-12-01
A rapid, reliable, and sensitive method for the detection of Cronobacter sakazakii, a common foodborne pathogen that may cause serious neonatal disease, has been developed. In this study, a rapid real-time quantitative PCR (qPCR) assay combined with sodium deoxycholate (SD) and propidium monoazide (PMA) was developed to detect C. sakazakii contamination in powdered infant formula (PIF). This method could eliminate the interference from dead or injured bacteria. Optimization studies indicated that SD and PMA at 0.08% (wt/vol) and 5µg/mL, respectively, were the most appropriate. In addition, qPCR, PMA-qPCR, SD-PMA-qPCR, and plate count assays were used to account for the number of viable bacteria in cell suspensions that were exposed to a 55°C water bath at different length of time. As a result, the viable number by PMA-qPCR showed significantly higher than of the number from SD-PMA-qPCR or plate counts. The number of viable bacteria was consistent between SD-PMA-qPCR and traditional plate counts, which indicated that SD treatment could eliminate the interference from dead or injured cells. Using the optimized parameters, the limit of detection with the SD-PMA-qPCR assay was 3.3×10 2 cfu/mL and 4.4×10 2 cfu/g in pure culture and in spiked PIF, respectively. A similar detection limit of 5.6×10 2 cfu/g was obtained in the presence of the Staphylococcus aureus (10 7 cfu/mL). The combined SD-PMA-qPCR assay holds promise for the rapid detection of viable C. sakazakii in PIF. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Limited evidence of intercontinental dispersal of avian paramyxovirus serotype 4 by migratory birds
Reeves, Andrew; Poulson, Rebecca L.; Muzyka, Denys; Ogawa, Haruko; Imai, Kunitoshi; Nghia Bui, Vuong; Hall, Jeffrey S.; Pantin-Jackwood, Mary; Stallknecht, David E.; Ramey, Andrew M.
2016-01-01
Avian paramyxovirus serotype 4 (APMV-4) is a single stranded RNA virus that has most often been isolated from waterfowl. Limited information has been reported regarding the prevalence, pathogenicity, and genetic diversity of AMPV-4. To assess the intercontinental dispersal of this viral agent, we sequenced the fusion gene of 58 APMV-4 isolates collected in the United States, Japan and the Ukraine and compared them to all available sequences on GenBank. With only a single exception the phylogenetic clades of APMV-4 sequences were monophyletic with respect to their continents of origin (North America, Asia and Europe). Thus, we detected limited evidence for recent intercontinental dispersal of APMV-4 in this study.
Lysák, Daniel; Holubová, Monika; Bergerová, Tamara; Vávrová, Monika; Cangemi, Giuseppina Cristina; Ciccocioppo, Rachele; Kruzliak, Peter; Jindra, Pavel
2016-03-01
Cell therapy products represent a new trend of treatment in the field of immunotherapy and regenerative medicine. Their biological nature and multistep preparation procedure require the application of complex release criteria and quality control. Microbial contamination of cell therapy products is a potential source of morbidity in recipients. The automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However the standard 2-week cultivation period is too long for some cell-based treatments and alternative methods have to be devised. We tried to verify whether a shortened cultivation of the supernatant from the mesenchymal stem cell (MSC) culture obtained 2 days before the cell harvest could sufficiently detect microbial growth and allow the release of MSC for clinical application. We compared the standard Ph. Eur. cultivation method and the automated blood culture system BACTEC (Becton Dickinson). The time to detection (TTD) and the detection limit were analyzed for three bacterial and two fungal strains. The Staphylococcus aureus and Pseudomonas aeruginosa were recognized within 24 h with both methods (detection limit ~10 CFU). The time required for the detection of Bacillus subtilis was shorter with the automated method (TTD 10.3 vs. 60 h for 10-100 CFU). The BACTEC system reached significantly shorter times to the detection of Candida albicans and Aspergillus brasiliensis growth compared to the classical method (15.5 vs. 48 and 31.5 vs. 48 h, respectively; 10-100 CFU). The positivity was demonstrated within 48 h in all bottles, regardless of the size of the inoculum. This study validated the automated cultivation system as a method able to detect all tested microorganisms within a 48-h period with a detection limit of ~10 CFU. Only in case of B. subtilis, the lowest inoculum (~10 CFU) was not recognized. The 2-day cultivation technique is then capable of confirming the microbiological safety of MSC and allows their timely release for clinical application.
Cost and detection rate of glaucoma screening with imaging devices in a primary care center
Anton, Alfonso; Fallon, Monica; Cots, Francesc; Sebastian, María A; Morilla-Grasa, Antonio; Mojal, Sergi; Castells, Xavier
2017-01-01
Purpose To analyze the cost and detection rate of a screening program for detecting glaucoma with imaging devices. Materials and methods In this cross-sectional study, a glaucoma screening program was applied in a population-based sample randomly selected from a population of 23,527. Screening targeted the population at risk of glaucoma. Examinations included optic disk tomography (Heidelberg retina tomograph [HRT]), nerve fiber analysis, and tonometry. Subjects who met at least 2 of 3 endpoints (HRT outside normal limits, nerve fiber index ≥30, or tonometry ≥21 mmHg) were referred for glaucoma consultation. The currently established (“conventional”) detection method was evaluated by recording data from primary care and ophthalmic consultations in the same population. The direct costs of screening and conventional detection were calculated by adding the unit costs generated during the diagnostic process. The detection rate of new glaucoma cases was assessed. Results The screening program evaluated 414 subjects; 32 cases were referred for glaucoma consultation, 7 had glaucoma, and 10 had probable glaucoma. The current detection method assessed 677 glaucoma suspects in the population, of whom 29 were diagnosed with glaucoma or probable glaucoma. Glaucoma screening and the conventional detection method had detection rates of 4.1% and 3.1%, respectively, and the cost per case detected was 1,410 and 1,435€, respectively. The cost of screening 1 million inhabitants would be 5.1 million euros and would allow the detection of 4,715 new cases. Conclusion The proposed screening method directed at population at risk allows a detection rate of 4.1% and a cost of 1,410 per case detected. PMID:28243057
Kawase, Jun; Etoh, Yoshiki; Ikeda, Tetsuya; Yamaguchi, Keiji; Watahiki, Masanori; Shima, Tomoko; Kameyama, Mitsuhiro; Horikawa, Kazumi; Fukushima, Hiroshi; Goto, Ryoichi; Shirabe, Komei
2016-05-20
Here, we developed a new version of our original screening system (Rapid Foodborne Bacterial Screening 24; RFBS24), which can simultaneously detect 24 genes of foodborne pathogens in fecal DNA samples. This new version (RFBS24 ver. 5) detected all known stx2 subtypes, enterotoxigenic Escherichia coli (STh genotype), and Vibrio parahaemolyticus (trh2), which were not detected by the original RFBS24 assay. The detection limits of RFBS24 ver. 5 were approximately 5.6 × 10(-2)-5.6 × 10(-5) (ng DNA)/reaction, significantly lower (10- to 100-fold) than those of the original RFBS24 for the 22 target genes analyzed here. We also tested the new assay on fecal DNA samples from patients infected with Salmonella, Campylobacter, or enterohemorrhagic E. coli. The number of bacterial target genes detected by RFBS24 ver. 5 was greater than that detected by RFBS24. RFBS24 ver. 5 combined with an Ultra Clean Fecal DNA Isolation Kit showed adequate performance (sensitivity and specificity 89% and 100%, respectively, for Salmonella spp. and 100% and 83%, respectively, for Campylobacter jejuni) in terms of rapid detection of a causative pathogen during foodborne-illness outbreaks. Thus, RFBS24 ver. 5 is more useful than the previous assay system for detection of foodborne pathogens and offers quick simultaneous analysis of many targets and thus facilitates rapid dissemination of information to public health officials.
Czerwiecki, Ludwik; Czyzyk, Kamila; Kwiecień, Agnieszka; Wilczyńska, Grazyna
2004-01-01
The method for ochratoxin A determination in cereals (wheat, rye) was described. Application of immunoaffinity columns (IAC) for clean-up of extracts was investigated. The ochratoxin A content was determined by high-performance liquid chromatography using C18 column and fluorimetric detection at 330 nm (excitation) and 460 nm (emission). The mean recovery of ochratoxin A was 65-78%. The limits of detection (LOD) and quantification (LOQ) were 0.015 and 0.025 microg/kg, respectively. The positive results were confirmed by reaction with BF3 complex in methanol.
N-nitrosodimethylamine, nitrate and nitrate-reducing microorganisms in human milk.
Uibu, J; Tauts, O; Levin, A; Shimanovskaya, N; Matto, R
1996-10-01
Of 54 milk samples from 54 healthy nursing women analysed for volatile N-nitrosamines, 42 appeared negative. Trace amounts (below the detection limit 0.5 microgram l-1) of N-nitrosodimethylamine were detected in the milk of 10 mothers and two samples contained this compound at 1.1 and 1.2 micrograms 1-1 respectively. Almost all samples investigated contained nitrate (mean 2.9 +/- 2.3 mg1-1 and nitrate reducing microorganisms (mean 4.2 +/- 1.0 log ml-1). The recent finding of N-nitrosodimethylamine in human milk gives evidence of the continuous endogenous formation of N-nitrosamines.
Voltammetry as a Tool for Characterization of CdTe Quantum Dots
Sobrova, Pavlina; Ryvolova, Marketa; Hubalek, Jaromir; Adam, Vojtech; Kizek, Rene
2013-01-01
Electrochemical detection of quantum dots (QDs) has already been used in numerous applications. However, QDs have not been well characterized using voltammetry, with respect to their characterization and quantification. Therefore, the main aim was to characterize CdTe QDs using cyclic and differential pulse voltammetry. The obtained peaks were identified and the detection limit (3 S/N) was estimated down to 100 fg/mL. Based on the convincing results, a new method for how to study stability and quantify the dots was suggested. Thus, the approach was further utilized for the testing of QDs stability. PMID:23807507
Wu, Ping-Hsiu; Lin, Yu-Min; Liao, Chao-Sheng; Chang, Hung-Chuen; Chen, Yu-Hung; Yang, Kuo-Ching; Shih, Chia-Hui
2013-06-01
The Taiwanese government has proposed a population-based colorectal tumor detection program for the average-risk population. This study's objectives were to understand the outcomes of these screening policies and to evaluate the effectiveness of the program. We compared two databases compiled in one medical center. The "policy-promoted cancer screening" (PPS) database was built on the basis of the policy of the Taiwan Bureau of National Health Insurance for cancer screening. The "health promotion service" (HPS) database was built to provide health check-ups for self-paid volunteers. Both the PPS and HPS databases employ the immunochemical fecal occult blood test (iFOBT) and colonoscopy for colorectal tumor screening using different strategies. A comparison of outcomes between the PPS and HPS included: (1) quality indicators-compliance rate, cecum reaching rate, and tumor detection rate; and (2) validity indicators-sensitivity, specificity, positive, and negative predictive values for detecting colorectal neoplasms. A total of 10,563 and 1481 individuals were enrolled in PPS and HPS, respectively. Among quality indicators, there was no statistically significant difference in the cecum reaching rate between PPS and HPS. The compliance rates were 56.1% for PPS and 91.8% for HPS (p < 0.001). The advanced adenoma detection rates of PPS and HPS were 1.0% and 3.6%, respectively (p < 0.01). The carcinoma detection rates were 0.3% and 0.4%, respectively (p = 0.59). For validity indicators, PPS provides only a positive predictive value for colorectal tumor detection. HPS provides additional validity indicators, including sensitivity, specificity, positive predictive value, and negative predictive value, for colorectal tumor screening. In comparison with the outcomes of the HPS database, the screening efficacy of the PPS database is even for detecting colorectal carcinoma but is limited in detecting advanced adenoma. HPS may provide comprehensive validity indicators and will be helpful in adjusting current policies for improving screening performance. Copyright © 2013. Published by Elsevier B.V.
Impedance Biosensing to detect food allergens, endocrine disrupting chemicals, and food pathogens
NASA Astrophysics Data System (ADS)
Radhakrishnan, Rajeswaran
Electrochemical impedance biosensors can be viewed as an AC electroanalytical method for the analyte detection in the fields of biomedicine, environmental monitoring, and food and agriculture, amongst others. The most common format for AC impedance biosensing involves surface immobilization of an antibody, receptor protein, DNA strand, or other species capable of bio-recognition, and AC impedance detection of the binding event. Technological application of AC impedance biosensors has been hindered by several obstacles, including the more complex circuitry required for AC relative to DC electrochemistry, chemical and physical interference arising from non-specific adsorption, and the stability and reproducibility of protein immobilization. One focus of these PhD studies is on methods to reduce or compensate for non-specific adsorption, including sample dilution, site blocking with BSA, and the use of control electrodes onto which reference antibodies are immobilized. Examples that will be presented include impedance detection of food pathogens, such as Listeria monocytogenes, using a mouse monoclonal antibody immobilized onto an Au electrode. This yields detection limits of 5 CFU/ml and 4 CFU/ml for ideal solutions and filtered tomato extract, respectively. Control experiments with an Au electrode onto which a mouse monoclonal antibody to GAPDH is immobilized demonstrate that non-specific adsorption is insignificant for the system and methodology studied here. Control experiments with Salmonella enterica demonstrate no cross-reactivity to this food pathogen. In addition, Detection of two endocrine-disrupting chemicals (EDC), norfluoxetine and BDE-47, is reported here by impedance biosensing, with a detection limit of 8.5 and 1.3 ng/ml for norfluoxetine and BDE-47, respectively. Additional research has focused on alternative substrates and linker chemistries for protein immobilization, including the use of degenerate (highly doped) Si and bidendate thiol monolayer onto Au. Advantages of degenerate Si include a simpler equivalent circuit, simple and reproducible surface preparation, easy incorporation into ULSI devices, and the greater strength of Si-C bonds (~520 kJ/mole) relative to Au-S bonds (125-150 kJ/mole). New results demonstrating antibody regeneration atop degenerate (highly doped) Si are also reported. Using 0.2 M KSCN and 10 mM HF for antibody regeneration, peanut protein Ara h 1 is detected daily during a thirty-day trial. An impedance biosensor is reported that employs the bidentate thiol 16-[3,5-bis(mercaptomethyl)phenoxy]-hexadecanoic acid (BMPHA) to immobilize the mouse monoclonal antibody to peanut protein Ara h 1. The detection limit for Ara h 1 is approximately 0.71 ng/mL (0.01 nM), which is about one order of magnitude lower than that obtained for antibody immobilization atop the monodendate thiol, 16-mercaptohexadecanoic acid (16 MHA). Antibody regeneration was studied daily using a gentle denaturing agent, 0.2 M KSCN at pH 7.3. The antibody-coated on Au electrodes retained activity towards Ara h1 for 10 and 20 days of regeneration of the monodendate- and BMPHA-coated Au electrodes, respectively. This prolonged activity illustrates the superior stability of protein films atop the BMPHA bidentate thiol- coated Au electrode relative to the 16-MHA monodendate thiol-coated Au electrode.
Kim, Yong-Hyun; Kim, Ki-Hyun
2012-10-02
To understand the ultimately lowest detection range of volatile organic compounds (VOCs) in air, application of a high sensitivity analytical system was investigated by coupling thermal desorption (TD) technique with gas chromatography (GC) and time-of-flight (TOF) mass spectrometry (MS). The performance of the TD-GC/TOF MS system was evaluated using liquid standards of 19 target VOCs prepared in the range of 35 pg to 2.79 ng per μL. Studies were carried out using both total ion chromatogram (TIC) and extracted ion chromatogram (EIC) mode. EIC mode was used for calibration to reduce background and to improve signal-to-noise. The detectability of 19 target VOCs, if assessed in terms of method detection limit (MDL, per US EPA definition) and limit of detection (LOD), averaged 5.90 pg and 0.122 pg, respectively, with the mean coefficient of correlation (R(2)) of 0.9975. The minimum quantifiable mass of target analytes, when determined using real air samples by the TD-GC/TOF MS, is highly comparable to the detection limits determined experimentally by standard. In fact, volumes for the actual detection of the major aromatic VOCs like benzene, toluene, and xylene (BTX) in ambient air samples were as low as 1.0 mL in the 0.11-2.25 ppb range. It was thus possible to demonstrate that most target compounds including those in low abundance could be reliably quantified at concentrations down to 0.1 ppb at sample volumes of less than 10 mL. The unique sensitivity of this advanced analytical system can ultimately lead to a shift in field sampling strategy with smaller air sample volumes facilitating faster, simpler air sampling (e.g., use of gas syringes rather than the relative complexity of pumps or bags/canisters), with greatly reduced risk of analyte breakthrough and minimal interference, e.g., from atmospheric humidity. The improved detection limits offered by this system can also enhance accuracy and measurement precision.
Novel nanoarchitectures for electrochemical biosensing
NASA Astrophysics Data System (ADS)
Archibald, Michelle M.
Sensitive, real-time detection of biomarkers is of critical importance for rapid and accurate diagnosis of disease for point-of-care (POC) technologies. Current methods, while sensitive, do not adequately allow for POC applications due to several limitations, including complex instrumentation, high reagent consumption, and cost. We have investigated two novel nanoarchitectures, the nanocoax and the nanodendrite, as electrochemical biosensors towards the POC detection of infectious disease biomarkers to overcome these limitations. The nanocoax architecture is composed of vertically-oriented, nanoscale coaxial electrodes, with coax cores and shields serving as integrated working and counter electrodes, respectively. The dendritic structure consists of metallic nanocrystals extending from the working electrode, increasing sensor surface area. Nanocoaxial- and nanodendritic-based electrochemical sensors were fabricated and developed for the detection of bacterial toxins using an electrochemical enzyme-linked immunosorbent assay (ELISA) and differential pulse voltammetry (DPV). Proof-of-concept was demonstrated for the detection of cholera toxin (CT). Both nanoarchitectures exhibited levels of sensitivity that are comparable to the standard optical ELISA used widely in clinical applications. In addition to matching the detection profile of the standard ELISA, these electrochemical nanosensors provide a simple electrochemical readout and a miniaturized platform with multiplexing capabilities toward POC implementation. Further development as suggested in this thesis may lead to increases in sensitivity, enhancing the attractiveness of the architectures for future POC devices.
Granja, Rodrigo H M M; Niño, Alfredo M Montes; Zucchetti, Roberto A M; Niño, Rosario E Montes; Salerno, Alessandro G
2008-01-01
Ethopabate is frequently used in the prophylaxis and treatment of coccidiosis in poultry. Residues of this drug in food present a potential risk to consumers. A simple, rapid, and sensitive column high-performance liquid chromatographic (HPLC) method with UV detection for determination of ethopabate in poultry liver is presented. The drug is extracted with acetonitrile. After evaporation, the residue is dissolved with an acetone-hexane mixture and cleaned up by solid-phase extraction using Florisil columns. The analyte is then eluted with methanol. LC analysis is carried out on a C18 5 microm Gemini column, 15 cm x 4.6 mm. Ethopabate is quantified by means of UV detection at 270 nm. Parameters such as decision limit, detection capability, precision, recovery, ruggedness, and measurement uncertainty were calculated according to method validation guidelines provided in 2002/657/EC and ISO/IEC 17025:2005. Decision limit and detection capability were determined to be 2 and 3 microg/kg, respectively. Average recoveries from poultry samples fortified with 10, 15, and 20 microg/kg levels of ethopabate were 100-105%. A complete statistical analysis was performed on the results obtained, including an estimation of the method uncertainty. The method is to be implemented into Brazil's residue monitoring and control program for ethopabate.
Quintelas, Cristina; Mesquita, Daniela P; Lopes, João A; Ferreira, Eugénio C; Sousa, Clara
2015-08-15
Accurate detection and quantification of microbiological contaminations remains an issue mainly due the lack of rapid and precise analytical techniques. Standard methods are expensive and time-consuming being associated to high economic losses and public health threats. In the context of pharmaceutical industry, the development of fast analytical techniques able to overcome these limitations is crucial and spectroscopic techniques might constitute a reliable alternative. In this work we proved the ability of Fourier transform near infrared spectroscopy (FT-NIRS) to detect and quantify bacteria (Bacillus subtilis, Escherichia coli, Pseudomonas fluorescens, Salmonella enterica, Staphylococcus epidermidis) from 10 to 10(8) CFUs/mL in sterile saline solutions (NaCl 0.9%). Partial least squares discriminant analysis (PLSDA) models showed that FT-NIRS was able to discriminate between sterile and contaminated solutions for all bacteria as well as to identify the contaminant bacteria. Partial least squares (PLS) models allowed bacterial quantification with limits of detection ranging from 5.1 to 9 CFU/mL for E. coli and B. subtilis, respectively. This methodology was successfully validated in three pharmaceutical preparations (contact lens solution, cough syrup and topic anti-inflammatory solution) proving that this technique possess a high potential to be routinely used for the detection and quantification of bacterial contaminations. Copyright © 2015 Elsevier B.V. All rights reserved.
Li, P; Jia, J W; Jiang, L X; Zhu, H; Bai, L; Wang, J B; Tang, X M; Pan, A H
2012-04-27
To ensure the implementation of genetically modified organism (GMO)-labeling regulations, an event-specific detection method was developed based on the junction sequence of an exogenous integrant in the transgenic carnation variety Moonlite. The 5'-transgene integration sequence was isolated by thermal asymmetric interlaced PCR. Based upon the 5'-transgene integration sequence, the event-specific primers and TaqMan probe were designed to amplify the fragments, which spanned the exogenous DNA and carnation genomic DNA. Qualitative and quantitative PCR assays were developed employing the designed primers and probe. The detection limit of the qualitative PCR assay was 0.05% for Moonlite in 100 ng total carnation genomic DNA, corresponding to about 79 copies of the carnation haploid genome; the limit of detection and quantification of the quantitative PCR assay were estimated to be 38 and 190 copies of haploid carnation genomic DNA, respectively. Carnation samples with different contents of genetically modified components were quantified and the bias between the observed and true values of three samples were lower than the acceptance criterion (<25%) of the GMO detection method. These results indicated that these event-specific methods would be useful for the identification and quantification of the GMO carnation Moonlite.
Chahar, Madhvi; Mishra, Neelima; Anvikar, Anup; Dixit, Rajnikant; Valecha, Neena
2017-01-01
Chloroquine (CQ) resistance in Plasmodium falciparum is determined by the mutations in the chloroquine resistance transporter (Pfcrt) gene. The point mutation at codon 76 (K76T), which has been observed in more than 91% of P. falciparum isolates in India, is the major determinant of CQ resistance. To overcome the limitations and challenges of traditional methods, in this investigation we developed an easy to use loop mediated isothermal amplification (LAMP) protocol for rapid detection of the K76T mutation associated with CQ resistance in P. falciparum with naked eye visualization. In- house designed primers were synthesized and optimized to specifically distinguish the CQ resistant mutants of P. falciparum. The LAMP reaction was optimal at 61 °C for 60 min and calcein dye was added prior to amplification to enable visual detection. We demonstrate the detection limit of <2 ng/μl respectively, supporting the high sensitivity of this calcein based LAMP method. To the best of our knowledge this is the first report on the establishment of an easy, reliable and cost effective LAMP assay for rapid and specific detection of highly CQ resistance in P. falciparum malaria. PMID:28134241
Campillo-Gimenez, Boris; Garcelon, Nicolas; Jarno, Pascal; Chapplain, Jean Marc; Cuggia, Marc
2013-01-01
The surveillance of Surgical Site Infections (SSI) contributes to the management of risk in French hospitals. Manual identification of infections is costly, time-consuming and limits the promotion of preventive procedures by the dedicated teams. The introduction of alternative methods using automated detection strategies is promising to improve this surveillance. The present study describes an automated detection strategy for SSI in neurosurgery, based on textual analysis of medical reports stored in a clinical data warehouse. The method consists firstly, of enrichment and concept extraction from full-text reports using NOMINDEX, and secondly, text similarity measurement using a vector space model. The text detection was compared to the conventional strategy based on self-declaration and to the automated detection using the diagnosis-related group database. The text-mining approach showed the best detection accuracy, with recall and precision equal to 92% and 40% respectively, and confirmed the interest of reusing full-text medical reports to perform automated detection of SSI.
NASA Astrophysics Data System (ADS)
Song, Dandan; Qu, Xiaofeng; Liu, Yushen; Li, Li; Yin, Dehui; Li, Juan; Xu, Kun; Xie, Renguo; Zhai, Yue; Zhang, Huiwen; Bao, Hao; Zhao, Chao; Wang, Juan; Song, Xiuling; Song, Wenzhi
2017-03-01
Brucella spp. are facultative intracellular bacteria that cause zoonotic disease of brucellosis worldwide. Traditional methods for detection of Brucella spp. take 48-72 h that does not meet the need of rapid detection. Herein, a new rapid detection method of Brucella was developed based on polyclonal antibody-conjugating quantum dots and antibody-modified magnetic beads. First, polyclonal antibodies IgG and IgY were prepared and then the antibody conjugated with quantum dots (QDs) and immunomagnetic beads (IMB), respectively, which were activated by N-(3-dimethylaminopropyl)- N'-ethylcar-bodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to form probes. We used the IMB probe to separate the Brucella and labeled by the QD probe, and then detected the fluorescence intensity with a fluorescence spectrometer. The detection method takes 105 min with a limit of detection of 103 CFU/mL and ranges from 10 to 105 CFU/mL ( R 2 = 0.9983), and it can be well used in real samples.
Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan
2013-11-01
The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg(-1) GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25.
Application of a Subspace-Based Fault Detection Method to Industrial Structures
NASA Astrophysics Data System (ADS)
Mevel, L.; Hermans, L.; van der Auweraer, H.
1999-11-01
Early detection and localization of damage allow increased expectations of reliability, safety and reduction of the maintenance cost. This paper deals with the industrial validation of a technique to monitor the health of a structure in operating conditions (e.g. rotating machinery, civil constructions subject to ambient excitations, etc.) and to detect slight deviations in a modal model derived from in-operation measured data. In this paper, a statistical local approach based on covariance-driven stochastic subspace identification is proposed. The capabilities and limitations of the method with respect to health monitoring and damage detection are discussed and it is explained how the method can be practically used in industrial environments. After the successful validation of the proposed method on a few laboratory structures, its application to a sports car is discussed. The example illustrates that the method allows the early detection of a vibration-induced fatigue problem of a sports car.
Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25
Xu, Junyi; Zheng, Qiuyue; Yu, Ling; Liu, Ran; Zhao, Xin; Wang, Gang; Wang, Qinghua; Cao, Jijuan
2013-01-01
The loop-mediated isothermal amplification (LAMP) assay indicates a potential and valuable means for genetically modified organism (GMO) detection especially for its rapidity, simplicity, and low cost. We developed and evaluated the specificity and sensitivity of the LAMP method for rapid detection of the genetically modified (GM) maize T25. A set of six specific primers was successfully designed to recognize six distinct sequences on the target gene, including a pair of inner primers, a pair of outer primers, and a pair of loop primers. The optimum reaction temperature and time were verified to be 65°C and 45 min, respectively. The detection limit of this LAMP assay was 5 g kg−1 GMO component. Comparative experiments showed that the LAMP assay was a simple, rapid, accurate, and specific method for detecting the GM maize T25. PMID:24804053
Savoca, Mark E.; Tobias, Jennifer L.; Sadorf, Eric M.; Birkenholtz, Trevor L.
1997-01-01
Four herbicides (alachlor, atrazine, cyanazine, and metolachlor) and one nutrient (nitrate) were selected for study on the basis of frequent usage in Iowa and high detection rates in ground water (Detroy and Kuzniar, 1988). Alachlor was not detected at concentrations greater than the method detection limit (MDL). Atrazine was detected at concentrations greater than the MDL in samples from 48 percent of the 23 wells, cyanazine from 13 percent, metolachlor from 26 percent, and nitrate from 91 percent. None of the four herbicides were detected at concentrations greater than the respective U.S. Environmental Protection Agency's (USEPA) Maximum Contaminant Level (MCL) for drinking water. Thirteen percent of the samples had nitrate concentrations above the USEPA's MCL of 10 mg/L (milligrams per liter). Relations between constituent concentration and well depth were observed for specific constituents at individual well nests.
Eddy Current Testing for Detecting Small Defects in Thin Films
NASA Astrophysics Data System (ADS)
Obeid, Simon; Tranjan, Farid M.; Dogaru, Teodor
2007-03-01
Presented here is a technique of using Eddy Current based Giant Magneto-Resistance sensor (GMR) to detect surface and sub-layered minute defects in thin films. For surface crack detection, a measurement was performed on a copper metallization of 5-10 microns thick. It was done by scanning the GMR sensor on the surface of the wafer that had two scratches of 0.2 mm, and 2.5 mm in length respectively. In another experiment, metal coatings were deposited over the layers containing five defects with known lengths such that the defects were invisible from the surface. The limit of detection (resolution), in terms of defect size, of the GMR high-resolution Eddy Current probe was studied using this sample. Applications of Eddy Current testing include detecting defects in thin film metallic layers, and quality control of metallization layers on silicon wafers for integrated circuits manufacturing.
Analytical validation of viral CNS Flow Chip kit for detection of acute meningitis and encephalitis.
Pérez-Ruiz, Mercedes; Pedrosa-Corral, Irene; Sanbonmatsu-Gámez, Sara; Gómez-Camarasa, Cristina; Navarro-Marí, José María
2018-06-12
A new molecular assay (Viral CNS Flow Chip kit, Master Diagnóstica, Spain) has been developed for the detection of eight viruses causing acute meningitis and encephalitis, i.e. herpes simplex viruses 1-2, varicella zoster virus, human enterovirus, human parechovirus, Toscana virus, human cytomegalovirus and Epstein Barr virus. The new assay is a multiplex one-step RT-PCR followed by automatic flow-through hybridization, colorimetric detection and image analysis. The limit of detection was 50 copies/reaction, and 10 copies/reaction for human enterovirus and the other seven viruses, respectively. The analytical validation was performed with nucleic acids extracted from 268 cerebrospinal fluid samples and the results were compared with routine molecular assays. An excellent coefficient of agreement was observed between V-CNS and routine assays [kappa index: 0.948 (95%CI: 0.928-0.968)]. The overall sensitivity and specificity was 95.9% (95%CI: 91.2-98.3%) and 99.9% (95%CI: 99.6-100%), respectively. Viral CNS Flow Chip kit is an efficient multiplex platform for the detection of the main viruses involved in acute meningitis and encephalitis. The inclusion of a TOSV genome target may improve the laboratory diagnosis of viral neurological infections in endemic areas. Copyright © 2018 Elsevier B.V. All rights reserved.
Cabada, Miguel M.; Malaga, Jose L.; Castellanos-Gonzalez, Alejandro; Bagwell, Kelli A.; Naeger, Patrick A.; Rogers, Hayley K.; Maharsi, Safa; Mbaka, Maryann; White, A. Clinton
2017-01-01
Fasciola hepatica is the most widely distributed trematode infection in the world. Control efforts may be hindered by the lack of diagnostic capacity especially in remote endemic areas. Polymerase chain reaction (PCR)–based methods offer high sensitivity and specificity but require expensive technology. However, the recombinase polymerase amplification (RPA) is an efficient isothermal method that eliminates the need for a thermal cycler and has a high deployment potential to resource-limited settings. We report on the characterization of RPA and PCR tests to detect Fasciola infection in clinical stool samples with low egg burdens. The sensitivity of the RPA and PCR were 87% and 66%, respectively. Both tests were 100% specific showing no cross-reactivity with trematode, cestode, or nematode parasites. In addition, RPA and PCR were able to detect 47% and 26% of infections not detected by microscopy, respectively. The RPA adapted to a lateral flow platform was more sensitive than gel-based detection of the reaction products. In conclusion, the Fasciola RPA is a highly sensitive and specific test to diagnose chronic infection using stool samples. The Fasciola RPA lateral flow has the potential for deployment to endemic areas after further characterization. PMID:27821691
Caetano, F R; Carneiro, E A; Agustini, D; Figueiredo-Filho, L C S; Banks, C E; Bergamini, M F; Marcolino-Junior, L H
2018-01-15
Microfluidic devices constructed using low cost materials presents as alternative for conventional flow analysis systems because they provide advantages as low consumption of reagents and samples, high speed of analysis, possibility of portability and the easiness of construction and maintenance. Herein, is described for the first time the use of an electrochemical biosensor for phenol detection combined with a very simple and efficient microfluidic device based on commercial textile threads. Taking advantages of capillary phenomena and gravity forces, the solution transportation is promoted without any external forces or injection pump. Screen printed electrodes were modified with carbon nanotubes/gold nanoparticles followed by covalent binding of tyrosinase. After the biosensor electrochemical characterization by cyclic voltammetry technique, the optimization of relevant parameters such as pH, potential of detection and linear range for the biosensor performance was carried out; the system was evaluated for analytical phenol detection presenting limit of detection and limit of quantification 2.94nmolL -1 and 8.92nmolL -1 respectively. The proposed system was applied on phenol addition and recovery studies in drinking water, obtaining recoveries rates between 90% and 110%. Copyright © 2017 Elsevier B.V. All rights reserved.
Nedosekin, Dmitry A; Juratli, Mazen A; Sarimollaoglu, Mustafa; Moore, Christopher L; Rusch, Nancy J; Smeltzer, Mark S; Zharov, Vladimir P; Galanzha, Ekaterina I
2013-06-01
Circulating cells, bacteria, proteins, microparticles, and DNA in cerebrospinal fluid (CSF) are excellent biomarkers of many diseases, including cancer and infections. However, the sensitivity of existing methods is limited in their ability to detect rare CSF biomarkers at the treatable, early-stage of diseases. Here, we introduce novel CSF tests based on in vivo photoacoustic flow cytometry (PAFC) and ex vivo photothermal scanning cytometry. In the CSF of tumor-bearing mice, we molecularly detected in vivo circulating tumor cells (CTCs) before the development of breast cancer brain metastasis with 20-times higher sensitivity than with current assays. For the first time, we demonstrated assessing three pathways (i.e., blood, lymphatic, and CSF) of CTC dissemination, tracking nanoparticles in CSF in vivo and their imaging ex vivo. In label-free CSF samples, we counted leukocytes, erythrocytes, melanoma cells, and bacteria and imaged intracellular cytochromes, hemoglobin, melanin, and carotenoids, respectively. Taking into account the safety of PAFC, its translation for use in humans is expected to improve disease diagnosis beyond conventional detection limits. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Linz, Thomas H.; Snyder, Christa M.; Lunte, Susan M.
2013-01-01
The methylated arginines (MAs) monomethylarginine (MMA), asymmetric dimethylarginine (ADMA), and symmetric dimethylarginine (SDMA) have been shown to be independent predictors of cardiovascular disease. This article describes progress regarding the development of an analytical method capable of rapidly analyzing MAs using capillary electrophoresis (CE) and microchip electrophoresis (MCE) with laser-induced fluorescence (LIF) detection. Several parameters including buffer composition and separation voltage were optimized to achieve an ideal separation. The analytes of interest were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) to produce fluorescent 1-cyanobenz[f]isoindole (CBI) derivatives and then subjected to CE analysis. Baseline resolution of SDMA, ADMA, MMA, and arginine was achieved in less than 8 min. The limits of detection for SDMA, ADMA, MMA, and arginine were determined to be 15, 20, 25, and 5 nM, respectively, which are well below the expected plasma concentrations. The CE separation method was then transferred to a glass MCE device with LIF detection. MAs were baseline resolved in 3 min on-chip using a 14 cm separation channel with detection limits of approximately 10 nM for each species. To the best of the authors’ knowledge, this is the first report of the separation of MAs by MCE. PMID:22357605
Shin, Choonshik; Choi, Hoon; Kwon, Hye-Min; Jo, Hye-Jin; Kim, Hye-Jeong; Yoon, Hae-Jung; Kim, Dong-Sul; Kang, Gil-Jin
2017-10-01
The present study was carried out to survey the levels of plutonium isotopes ( 238 , 239 , 240 Pu) and strontium ( 90 Sr) in domestic seafood in Korea. In current, regulatory authorities have analyzed radionuclides, such as 134 Cs, 137 Cs and 131 I, in domestic and imported food. However, people are concerned about contamination of other radionuclides, such as plutonium and strontium, in food. Furthermore, people who live in Korea have much concern about safety of seafood. Accordingly, in this study, we have investigated the activity concentrations of plutonium and strontium in seafood. For the analysis of plutonium isotopes and strontium, a rapid and reliable method developed from previous study was used. Applicability of the test method was verified by examining recovery, minimum detectable activity (MDA), analytical time, etc. Total 40 seafood samples were analyzed in 2014-2015. As a result, plutonium isotopes ( 238 , 239 , 240 Pu) and strontium ( 90 Sr) were not detected or below detection limits in seafood. The detection limits of plutonium isotopes and strontium-90 were 0.01 and 1 Bq/kg, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Larivière, Dominic; Tremblay, Mélodie; Durand-Jézéquel, Myriam; Tolmachev, Sergei
2012-04-01
This article describes a robust methodology using the combination of instrumental design (high matrix interface-HMI), sample dilution and internal standardization for the quantification of beryllium (Be) in various digested autopsy tissues using inductively coupled plasma mass spectrometry. The applicability of rhodium as a proper internal standard for Be was demonstrated in three types of biological matrices (i.e., femur, hair, lung tissues). Using HMI, it was possible to achieve instrumental detection limits and sensitivity of 0.6 ng L(-1) and 157 cps L ng(-1), respectively. Resilience to high salt matrices of the HMI setup was also highlighted using bone mimicking solution ([Ca(2+)] = 26 to 1,400 mg L(-1)), providing a 14-fold increase in tolerance and a 2.7-fold decrease in method detection limit compared to optimized experimental conditions obtained without the HMI configuration. Precision of the methodology to detect low levels of Be in autopsy samples was demonstrated using hair and blood certified reference materials. Be concentration ranging from 0.015 to 255 μg kg(-1) in autopsy samples obtained from the U.S. Transuranium and Uranium Registries were measured using the methodology presented.
Saikaly, Pascal E.; Barlaz, Morton A.; de los Reyes, Francis L.
2007-01-01
Evaluation of the fate and transport of biological warfare (BW) agents in landfills requires the development of specific and sensitive detection assays. The objective of the current study was to develop and validate SYBR green quantitative real-time PCR (Q-PCR) assays for the specific detection and quantification of surrogate BW agents in synthetic building debris (SBD) and leachate. Bacillus atrophaeus (vegetative cells and spores) and Serratia marcescens were used as surrogates for Bacillus anthracis (anthrax) and Yersinia pestis (plague), respectively. The targets for SYBR green Q-PCR assays were the 16S-23S rRNA intergenic transcribed spacer (ITS) region and recA gene for B. atrophaeus and the gyrB, wzm, and recA genes for S. marcescens. All assays showed high specificity when tested against 5 ng of closely related Bacillus and Serratia nontarget DNA from 21 organisms. Several spore lysis methods that include a combination of one or more of freeze-thaw cycles, chemical lysis, hot detergent treatment, bead beat homogenization, and sonication were evaluated. All methods tested showed similar threshold cycle values. The limit of detection of the developed Q-PCR assays was determined using DNA extracted from a pure bacterial culture and DNA extracted from sterile water, leachate, and SBD samples spiked with increasing quantities of surrogates. The limit of detection for B. atrophaeus genomic DNA using the ITS and B. atrophaeus recA Q-PCR assays was 7.5 fg per PCR. The limits of detection of S. marcescens genomic DNA using the gyrB, wzm, and S. marcescens recA Q-PCR assays were 7.5 fg, 75 fg, and 7.5 fg per PCR, respectively. Quantification of B. atrophaeus vegetative cells and spores was linear (R2 > 0.98) over a 7-log-unit dynamic range down to 101 B. atrophaeus cells or spores. Quantification of S. marcescens (R2 > 0.98) was linear over a 6-log-unit dynamic range down to 102 S. marcescens cells. The developed Q-PCR assays are highly specific and sensitive and can be used for monitoring the fate and transport of the BW surrogates B. atrophaeus and S. marcescens in building debris and leachate. PMID:17720820
NASA Astrophysics Data System (ADS)
Ghaffarian, Saman; Ghaffarian, Salar
2014-11-01
This paper proposes an improved FastICA model named as Purposive FastICA (PFICA) with initializing by a simple color space transformation and a novel masking approach to automatically detect buildings from high resolution Google Earth imagery. ICA and FastICA algorithms are defined as Blind Source Separation (BSS) techniques for unmixing source signals using the reference data sets. In order to overcome the limitations of the ICA and FastICA algorithms and make them purposeful, we developed a novel method involving three main steps: 1-Improving the FastICA algorithm using Moore-Penrose pseudo inverse matrix model, 2-Automated seeding of the PFICA algorithm based on LUV color space and proposed simple rules to split image into three regions; shadow + vegetation, baresoil + roads and buildings, respectively, 3-Masking out the final building detection results from PFICA outputs utilizing the K-means clustering algorithm with two number of clusters and conducting simple morphological operations to remove noises. Evaluation of the results illustrates that buildings detected from dense and suburban districts with divers characteristics and color combinations using our proposed method have 88.6% and 85.5% overall pixel-based and object-based precision performances, respectively.
KONGKAPAN, Jutamart; POAPOLATHEP, Saranya; ISARIYODOM, Supaporn; KUMAGAI, Susumu; POAPOLATHEP, Amnart
2015-01-01
Mycotoxins are secondary fungal metabolites that are typically present in grain and feed ingredients used for animal feeds. An analytical method using LC-ESI-MS/MS was developed to quantify nine mycotoxins, consisting of aflatoxin B1 (AFB1), AFB2, AFG1, AFG2, T-2 toxin, deoxynivalenol (DON), nivalenol (NIV), zearalenone (ZEA) and ochratoxin A (OTA) in broiler feeds. In total, 100 samples of broiler feeds were collected from poultry farms in Central Thailand. The survey found that AFB1 and ZEA were the most prevalent mycotoxins in the feed samples at percentages of 93% and 63%, respectively. The limit of detections (LODs) of investigated mycotoxins was 0.20–0.78 ng/g. AFB2, DON, AFG1, NIV and T-2 toxin were also detectable at low contamination levels with percentages of 20%, 9%, 7%, 5% and 1%, respectively, whereas OTA and AFG2 were not detected in any of the feed samples. These results suggest that there is a very low level of risk of the exposure to mycotoxins in feeds obtained from broiler farms in Central Thailand. PMID:26477362
Nishiuchi, Yukiko; Tamaru, Aki; Suzuki, Yasuhiko; Kitada, Seigo; Maekura, Ryoji; Tateishi, Yoshitaka; Niki, Mamiko; Ogura, Hisashi; Matsumoto, Sohkichi
2014-06-01
We previously demonstrated the colonization of Mycobacterium avium complex in bathrooms by the conventional culture method. In the present study, we aimed to directly detect M. avium organisms in the environment using loop-mediated isothermal amplification (LAMP), and to demonstrate the efficacy of LAMP by comparing the results with those obtained by culture. Our data showed that LAMP analysis has detection limits of 100 fg DNA/reaction for M. avium. Using an FTA(®) elute card, DNA templates were extracted from environmental samples from bathrooms in the residences of 29 patients with pulmonary M. avium disease. Of the 162 environmental samples examined, 143 (88%) showed identical results by both methods; 20 (12%) and 123 (76%) samples were positive and negative, respectively, for M. avium. Of the remaining 19 samples (12%), seven (5%) and 12 (7%) samples were positive by the LAMP and culture methods, respectively. All samples that contained over 20 colony forming units/primary isolation plate, as measured by the culture method, were also positive by the LAMP method. Our data demonstrate that the combination of the FTA elute card and LAMP can facilitate prompt detection of M. avium in the environment.
Characterising dark matter searches at colliders and direct detection experiments: Vector mediators
Buchmueller, Oliver; Dolan, Matthew J.; Malik, Sarah A.; ...
2015-01-09
We introduce a Minimal Simplified Dark Matter (MSDM) framework to quantitatively characterise dark matter (DM) searches at the LHC. We study two MSDM models where the DM is a Dirac fermion which interacts with a vector and axial-vector mediator. The models are characterised by four parameters: m DM, M med , g DM and g q, the DM and mediator masses, and the mediator couplings to DM and quarks respectively. The MSDM models accurately capture the full event kinematics, and the dependence on all masses and couplings can be systematically studied. The interpretation of mono-jet searches in this framework canmore » be used to establish an equal-footing comparison with direct detection experiments. For theories with a vector mediator, LHC mono-jet searches possess better sensitivity than direct detection searches for light DM masses (≲5 GeV). For axial-vector mediators, LHC and direct detection searches generally probe orthogonal directions in the parameter space. We explore the projected limits of these searches from the ultimate reach of the LHC and multi-ton xenon direct detection experiments, and find that the complementarity of the searches remains. In conclusion, we provide a comparison of limits in the MSDM and effective field theory (EFT) frameworks to highlight the deficiencies of the EFT framework, particularly when exploring the complementarity of mono-jet and direct detection searches.« less
Liang, Zhanbei; Keeley, Ann
2011-01-01
Extraction of high-quality mRNA from Cryptosporidium parvum is a key step in PCR detection of viable oocysts in environmental samples. Current methods for monitoring oocysts are limited to water samples; therefore, the goal of this study was to develop a rapid and sensitive procedure for Cryptosporidium detection in soil samples. The efficiencies of five RNA extraction methods were compared (mRNA extraction with the Dynabeads mRNA Direct kit after chemical and physical sample treatments, and total RNA extraction methods using the FastRNA Pro Soil-Direct, PowerSoil Total RNA, E.Z.N.A. soil RNA, and Norgen soil RNA purification kits) for the direct detection of Cryptosporidium with oocyst-spiked sandy, loamy, and clay soils by using TaqMan reverse transcription-PCR. The study also evaluated the presence of inhibitors by synthesis and incorporation of an internal positive control (IPC) RNA into reverse transcription amplifications, used different facilitators (bovine serum albumin, yeast RNA, salmon DNA, skim milk powder, casein, polyvinylpyrrolidone, sodium hexametaphosphate, and Salmonella enterica serovar Typhi) to mitigate RNA binding on soil components, and applied various treatments (β-mercaptoethanol and bead beating) to inactivate RNase and ensure the complete lysis of oocysts. The results of spiking studies showed that Salmonella cells most efficiently relieved binding of RNA. With the inclusion of Salmonella during extraction, the most efficient mRNA method was Dynabeads, with a detection limit of 6 × 102 oocysts g−1 of sandy soil. The most efficient total RNA method was PowerSoil, with detection limits of 1.5 × 102, 1.5 × 103, and 1.5 × 104 C. parvum oocysts g−1 soil for sandy, loamy, and clay samples, respectively. PMID:21803904
Yu, Mengqun; Wang, Hong; Fu, Fei; Li, Linyao; Li, Jing; Li, Gan; Song, Yang; Swihart, Mark T; Song, Erqun
2017-04-04
The effective monitoring, identification, and quantification of pathogenic bacteria is essential for addressing serious public health issues. In this study, we present a universal and facile one-step strategy for sensitive and selective detection of pathogenic bacteria using a dual-molecular affinity-based Förster (fluorescence) resonance energy transfer (FRET) platform based on the recognition of bacterial cell walls by antibiotic and aptamer molecules, respectively. As a proof of concept, Vancomycin (Van) and a nucleic acid aptamer were employed in a model dual-recognition scheme for detecting Staphylococcus aureus (Staph. aureus). Within 30 min, by using Van-functionalized gold nanoclusters and aptamer-modified gold nanoparticles as the energy donor and acceptor, respectively, the FRET signal shows a linear variation with the concentration of Staph. aureus in the range from 20 to 10 8 cfu/mL with a detection limit of 10 cfu/mL. Other nontarget bacteria showed negative results, demonstrating the good specificity of the approach. When employed to assay Staph. aureus in real samples, the dual-recognition FRET strategy showed recoveries from 99.00% to the 109.75% with relative standard derivations (RSDs) less than 4%. This establishes a universal detection platform for sensitive, specific, and simple pathogenic bacteria detection, which could have great impact in the fields of food/public safety monitoring and infectious disease diagnosis.
Zhou, Zi-Ming; Yu, Yong; Zhao, Yuan-Di
2012-09-21
We designed an aptasensor for the detection of adenosine triphosphate (ATP) based on chemiluminescence resonance energy transfer (CRET). An adenosine aptamer was cut into two pieces of ssDNA, which were attached to quantum dots (QDs) and horse radish peroxidase (HRP), respectively. They could reassemble into specific structures in the presence of ATP and then decrease the distance of HRP and QDs. ATP detection can be easily realized according to the fluorescent intensity of QDs, which is excited by CRET between luminol and QDs. Results show that the concentration of ATP is linear relation with the fluorescent intensity of the peak of QDs emission and the linear range for the linear equation is from 50 μM to 231 μM and the detection limit was 185 nM. When the concentration of ATP was 2 mM, the efficiency of CRET is 13.6%. Good specificity for ATP had been demonstrated compared to thymidine triphosphate (TTP), cytidine triphosphate (CTP) and guanosine triphosphate (GTP), when 1 mM of each was added, respectively. This method needs no external light source and can avoid autofluorescence and photobleaching, and ATP can be detected selectively, specifically, and sensitively in a low micromolar range, which means that the strategy reported here can be applicable to the detection of several other target molecules.
Kuhlmann, O; Stoldt, G; Struck, H G; Krauss, G J
1998-09-01
A sensitive and selective bioanalytical method for simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor using reversed-phase HPLC and electrochemical detection is described. Chromatographic separation was achieved by using a Regis SPS 100 RP-8 column (5 microns; 150 x 4.6 mm I.D.). This support is coated with a hydrophilic polyoxyethylenepolymer. It allows protein-containing samples to be injected directly onto the column. The electrochemical detector permit a detection limit of 500 pg diclofenac per ml (daily relative standard deviation 6.3%) and 50 ng oxybuprocaine per ml (daily R.S.D. 2.6%), respectively. Results of administered and measured drug-concentrations in time dependent decrease are presented.
Excimer-monomer switch: a reaction-based approach for selective detection of fluoride.
Song, Qiao; Bamesberger, Angela; Yang, Lingyun; Houtwed, Haley; Cao, Haishi
2014-07-21
A N-aryl-1,8-naphthalimide based sensor (ES-1) bearing a trimethylsilyl ether has been synthesized by a two-step reaction for quantitative detection of fluoride (F(-)). ES-1 exhibited monomer/excimer emissions at 410 and 524 nm respectively in CH2Cl2. In the presence of F(-), the desilylation of trimethylsilyl ether caused decay of the excimer emission as well as enhancement of the monomer emission to give a ratiometric signal. The fluoride-triggered desilylation showed a high reaction rate and high affinity to F(-) over nine other interfering anions. ES-1 provided a novel fluorescence assay based on excimer-monomer switch of N-aryl-1,8-naphthalimide to quantitatively measure F(-) with a detection limit of 0.133 ppm.
Tellapragada, Chaitanya; Shaw, Tushar; D'Souza, Annet; Eshwara, Vandana Kalwaje; Mukhopadhyay, Chiranjay
2017-07-01
To evaluate the diagnostic utility of enrichment culture and PCR for improved case detection rates of non-bacteraemic form of melioidosis in limited resource settings. Clinical specimens (n = 525) obtained from patients presenting at a tertiary care hospital of South India with clinical symptoms suggestive of community-acquired pneumonia, lower respiratory tract infections, superficial or internal abscesses, chronic skin ulcers and bone or joint infections were tested for the presence of Burkholderia pseudomallei using conventional culture (CC), enrichment culture (EC) and PCR. Sensitivity, specificity, positive and negative predictive values of CC and PCR were initially deduced using EC as the gold standard method. Further, diagnostic accuracies of all the three methods were analysed using Bayesian latent class modelling (BLCM). Detection rates of B. pseudomallei using CC, EC and PCR were 3.8%, 5.3% and 6%, respectively. Diagnostic sensitivities and specificities of CC and PCR were 71.4, 98.4% and 100 and 99.4%, respectively in comparison with EC as the gold standard test. With Bayesian latent class modelling, EC and PCR demonstrated sensitivities of 98.7 and 99.3%, respectively, while CC showed a sensitivity of 70.3% for detection of B. pseudomallei. An increase of 1.6% (95% CI: 1.08-4.32%) in the case detection rate of melioidosis was observed in the study population when EC and/or PCR were used in adjunct to the conventional culture technique. Our study findings underscore the diagnostic superiority of enrichment culture and/or PCR over conventional microbiological culture for improved case detection of melioidosis from non-blood clinical specimens. © 2017 John Wiley & Sons Ltd.
Hohnadel, Marisa; Maumy, Myriam; Chollet, Renaud
2018-01-01
For nearly a century, conventional microbiological methods have been standard practice for detecting and identifying pathogens in food. Nevertheless, the microbiological safety of food has improved and various rapid methods have been developed to overcome the limitations of conventional methods. Alternative methods are expected to detect low cell numbers, since the presence in food of even a single cell of a pathogenic organism may be infectious. With respect to low population levels, the performance of a detection method is assessed by producing serial dilutions of a pure bacterial suspension to inoculate representative food matrices with highly diluted bacterial cells (fewer than 10 CFU/ml). The accuracy of data obtained by multiple dilution techniques is not certain and does not exclude some colonies arising from clumps of cells. Micromanipulation techniques to capture and isolate single cells from environmental samples were introduced more than 40 years ago. The main limitation of the current micromanipulation technique is still the low recovery rate for the growth of a single cell in culture medium. In this study, we describe a new single cell isolation method and demonstrate that it can be used successfully to grow various types of microorganism from picked individual cells. Tests with Gram-positive and Gram-negative organisms, including cocci, rods, aerobes, anaerobes, yeasts and molds showed growth recovery rates from 60% to 100% after micromanipulation. We also highlight the use of our method to evaluate and challenge the detection limits of standard detection methods in food samples contaminated by a single cell of Salmonella enterica.
NASA Astrophysics Data System (ADS)
Wobrauschek, P.; Prost, J.; Ingerle, D.; Kregsamer, P.; Misra, N. L.; Streli, C.
2015-08-01
The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm2 active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.
Guo, Yun; Zhao, Wen-Jie; Deng, Zhi-Fen; Hongbo, Wang; Peng, Bin; Ma, Xue; Lan, Chen; Zhang, Shu-Sheng
2018-06-01
Benzo[α]pyrene (BaP) is a well-known carcinogen in edible oil. In this study, a method combined solid-phase extraction (SPE) with fluorescent detection was developed using tetraoxocalix[2]arene[2]triazine sorbent (SiO 2 -OCA) for the clean-up and enrichment of BaP. The interaction between SiO 2 -OCA and BaP involves a donor-acceptor complex mechanism. The experimental procedure was as follows: BaP was extracted from edible oil with DMF/H 2 O (9:1, v/v). Then, the ratio of DMF/H 2 O was adjusted to 1:2 prior to SPE. The final concentrate was analyzed using a fluorescence detector at excitation and emission wavelengths of 255 and 420 nm. The method was fully validated. The linearity was in the range of 0.1-100 μg kg -1 with a coefficient of 0.999. The limits of detection and quantification were 0.03 and 0.1 μg kg -1 , respectively. The average recoveries were in the range of 88.0-122.3%. The intraday and interday precisions were 6.8% and 9.2%, respectively. Compared with other methods, the method reported in this article shows a good detection limit, high reproducibility and recovery, and linearity over a broad concentration range. This established method was also applied to evaluate real samples. The concentration of six tested samples was below 5 μg kg -1 .
Amanolahi, Farjad; Mohammadi, Ali; Kazemi Oskuee, Reza; Nassirli, Hooriyeh; Malaekeh-Nikouei, Bizhan
2017-01-01
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55, v/v, pH 3.5), C18 column (150 mm×4.6 mm×5 µm particle size) and a flow rate of 1 ml/min in ambient condition and total retention time of 17 min. The volume of injection was set at 20 µl and detection was recorded at 425 nm. The robustness of the method was examined by changing the mobile phase composition, mobile phase pH, and flow rate. Results: The method was validated with respect to precision, accuracy and linearity in a concentration range of 2-100 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.5 µg/ml, respectively. The percentage of recovery was 98.9 to 100.5 with relative standard deviation (RSD) < 0.638%. Conclusion: The method was found to be simple, sensitive and rapid for determination of curcumin in pharmaceutical samples and had enough sensitivity to detect degradation product of curcumin produced under photolysis and hydrolysis stress condition. PMID:29062806
Huber, Charles S; Vale, Maria Goreti R; Dessuy, Morgana B; Svoboda, Milan; Musil, Stanislav; Dědina, Jiři
2017-12-01
A slurry sampling procedure for arsenic speciation analysis in baby food by arsane generation, cryogenic trapping and detection with atomic absorption spectrometry is presented. Several procedures were tested for slurry preparation, including different reagents (HNO 3 , HCl and tetramethylammonium hydroxide - TMAH) and their concentrations, water bath heating and ultrasound-assisted agitation. The best results for inorganic arsenic (iAs) and dimethylarsinate (DMA) were reached when using 3molL -1 HCl under heating and ultrasound-assisted agitation. The developed method was applied for the analysis of five porridge powder and six baby meal samples. The trueness of the method was checked with a certified reference material (CRM) of total arsenic (tAs), iAs and DMA in rice (ERM-BC211). Arsenic recoveries (mass balance) for all samples and CRM were performed by the determination of the tAs by inductively coupled plasma mass spectrometry (ICP-MS) after microwave-assisted digestion and its comparison against the sum of the results from the speciation analysis. The relative limits of detection were 0.44, 0.24 and 0.16µgkg -1 for iAs, methylarsonate and DMA, respectively. The concentrations of the most toxic arsenic species (iAs) in the analyzed baby food samples ranged between 4.2 and 99µgkg -1 which were below the limits of 300, 200 and 100µgkg -1 set by the Brazilian, Chinese and European legislation, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Taheri, Salman; Jalali, Fahimeh; Fattahi, Nazir; Jalili, Ronak; Bahrami, Gholamreza
2015-10-01
Dispersive liquid-liquid microextraction based on solidification of floating organic droplet was developed for the extraction of methadone and determination by high-performance liquid chromatography with UV detection. In this method, no microsyringe or fiber is required to support the organic microdrop due to the usage of an organic solvent with a low density and appropriate melting point. Furthermore, the extractant droplet can be collected easily by solidifying it at low temperature. 1-Undecanol and methanol were chosen as extraction and disperser solvents, respectively. Parameters that influence extraction efficiency, i.e. volumes of extracting and dispersing solvents, pH, and salt effect, were optimized by using response surface methodology. Under optimal conditions, enrichment factor for methadone was 134 and 160 in serum and urine samples, respectively. The limit of detection was 3.34 ng/mmL in serum and 1.67 ng/mL in urine samples. Compared with the traditional dispersive liquid-liquid microextraction, the proposed method obtained lower limit of detection. Moreover, the solidification of floating organic solvent facilitated the phase transfer. And most importantly, it avoided using high-density and toxic solvents of traditional dispersive liquid-liquid microextraction method. The proposed method was successfully applied to the determination of methadone in serum and urine samples of an addicted individual under methadone therapy. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Fan; Yu, Shuxin; Tang, Tao; Sun, Yuanshe; Zhang, Weibing; Li, Tong
2011-09-01
Laser-induced fluorescence detector (LIFD) is one of the most sensitive detectors in analytical chemical files. Confocal optical configuration is widely used in LIFDs. Two effective approaches used to achieve the best signal to noise ratio (S/N) are increasing the confocal precision and minimizing the background noise. A novel three-dimensional adjustable confocal LIFD was developed, using a new three-dimensional adjustable supporter of reflector and modularized optical system. A detection limit (S/N = 3) of 1 x 10(-12) mol/L and a linear dynamic range of 3 orders of magnitude were obtained using fluorescein isothiocyanate (FITC) standard as the test sample. The noise level and drift levels were 8.0 x 10(-3) mV and 1.4 x 10(-3) mV/h, respectively, which were almost 10 times lower than before. And the stability of the LIFD was evaluated by five replicate injections of 5 x 10(-9) mol/L FITC, and the relative standard deviations (RSDs) of peak height and peak area were 0.38% and 0.41%, respectively. Further more, three biogenic amines, which were derivatized by FITC, were separated by high performance liquid chromatography (HPLC) and then detected by the novel LIFD. And the detection limits (S/N = 3) ranged 0.01 to 0.02 nmol/L, which were better than other methods. Therefore, the LIFD is highly sensitive, as well as shows a real low noise level and good reproducibility.
Bendahl, Lars; Hansen, Steen Honoré; Gammelgaard, Bente; Sturup, Stefan; Nielsen, Camilla
2006-02-24
Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, the resolution of the test substances was only slightly affected when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). However, the sensitivity of ICP-MS detection decreased when the linear flow velocity was increased from 0.5 to 1.9 mm s(-1). Analytical figures of merit were determined at an intermediate and at a high linear velocity. The precision was better than 2.2% R.S.D. and regression analysis showed that a linear response was achieved at both flow rates (R2 > 0.9993, n = 36). The analysis time was less than 4.5 min at a flow rate of 50 microL min(-1) and limits of detection and quantification were better than 3.3 and 11 microg BrL(-1), respectively. The analysis time was reduced to 2.7 min when the flow rate was increased to 90 microL min(-1) and limits of detection and quantification were better than 20 and 65 microg BrL(-1), respectively. The method was applied for quantitative analysis of bromine-containing preservatives in commercially available cosmetic products.
Sidor, Inga F; Dunn, J Lawrence; Tsongalis, Gregory J; Carlson, Jolene; Frasca, Salvatore
2013-01-01
Brucellosis has emerged as a disease of concern in marine mammals in the last 2 decades. Molecular detection techniques have the potential to address limitations of other methods for detecting infection with Brucella in these species. Presented herein is a real-time polymerase chain reaction (PCR) method targeting the Brucella genus-specific bcsp31 gene. The method also includes a target to a conserved region of the eukaryotic mitochondrial 16S ribosomal RNA gene to assess suitability of extracted DNA and a plasmid-based internal control to detect failure of PCR due to inhibition. This method was optimized and validated to detect Brucella spp. in multiple sample matrices, including fresh or frozen tissue, blood, and feces. The analytical limit of detection was low, with 95% amplification at 24 fg, or an estimated 7 bacterial genomic copies. When Brucella spp. were experimentally added to tissue or fecal homogenates, the assay detected an estimated 1-5 bacteria/µl. An experiment simulating tissue autolysis showed relative persistence of bacterial DNA compared to host mitochondrial DNA. When used to screen 1,658 field-collected marine mammal tissues in comparison to microbial culture, diagnostic sensitivity and specificity were 70.4% and 98.3%, respectively. In addition to amplification in fresh and frozen tissues, Brucella spp. were detected in feces and formalin-fixed, paraffin-embedded tissues from culture-positive animals. Results indicate the utility of this real-time PCR for the detection of Brucella spp. in marine species, which may have applications in surveillance or epidemiologic investigations.
Kerr-Phillips, Thomas E; Aydemir, Nihan; Chan, Eddie Wai Chi; Barker, David; Malmström, Jenny; Plesse, Cedric; Travas-Sejdic, Jadranka
2018-02-15
A highly selective, label-free sensor for the non-Hodgkin lymphoma gene, with an aM detection limit, utilizing electrochemical impedance spectroscopy (EIS) is presented. The sensor consists of a conducting electrospun fibre mat, surface-grafted with poly(acrylic acid) (PAA) brushes and a conducting polymer sensing element with covalently attached oligonucleotide probes. The sensor was fabricated from electrospun NBR rubber, embedded with poly(3,4-ethylenedioxythiophene) (PEDOT), followed by grafting poly(acrylic acid) brushes and then electrochemically polymerizing a conducting polymer monomer with ssDNA probe sequence pre-attached. The resulting non-Hodgkin lymphoma gene sensor showed a detection limit of 1aM (1 × 10 -18 mol/L), more than 400 folds lower compared to a thin-film analogue. The sensor presented extraordinary selectivity, with only 1%, 2.7% and 4.6% of the signal recorded for the fully non-complimentary, T-A and G-C base mismatch oligonucleotide sequences, respectively. We suggest that such greatly enhanced selectivity is due to the presence of negatively charged carboxylic acid moieties from PAA grafts that electrostatically repel the non-complementary and mismatch DNA sequences, overcoming the non-specific binding. Copyright © 2017 Elsevier B.V. All rights reserved.
Determination of Fe, Hg, Mn, and Pb in three-rings of poplar (Populus alba L.) by U-shaped DC arc
NASA Astrophysics Data System (ADS)
Marković, D. M.; Novović, I.; Vilotić, D.; Ignjatović, Lj.
2007-09-01
The U-shaped DC arc with aerosol supply was applied for the determination of Fe, Hg, Mn, and Pb in poplar (Populus alba L.) tree-rings. By optimization of the operating parameters and by selection of the most appropriate signal integration time (20 s for Fe, Mn, and Pb and 30 s for Hg), the obtained limits of detection for Fe, Hg, Mn, and Pb are 5.8, 2.6, 1.6, and 2.0 ng/ml, respectively. The detection limits achieved by this method for Fe, Hg, Mn, and Pb are comparable with the detection limits obtained for these elements by such methods as inductively coupled plasma-atomic emission spectrometry (ICP-AES), direct coupled plasmatomic emission spectrometry (DCP-AES), and microwave-induced plasma-atomic emission spectrometry (MIP-AES). We used the tree-rings of poplar from two different locations. The first one is in the area close to the power plant “Nikola Tesla” TENT A, Obrenovac, while the other one is in the urban area of Novi Sad. In almost all cases, samples from the location at Obrenovac registered elevated average concentrations of Fe, Hg, Mn, and Pb in the tree-rings of poplar.
Relevance of drinking water as a source of human exposure to bisphenol A.
Arnold, Scott M; Clark, Kathryn E; Staples, Charles A; Klecka, Gary M; Dimond, Steve S; Caspers, Norbert; Hentges, Steven G
2013-03-01
A comprehensive search of studies describing bisphenol A (BPA) concentrations in drinking water and source waters (i.e., surface water and groundwater) was conducted to evaluate the relevance of drinking water as a source of human exposure and risk. Data from 65 papers were evaluated from North America (31), Europe (17), and Asia (17). The fraction of drinking water measurements reported as less than the detection limit is high; 95%, 48%, and 41%, for North America, Europe, and Asia, respectively. The maximum quantified (in excess of the detection limit) BPA concentrations from North America, Europe, and Asia are 0.099 μg/l, 0.014 μg/l, and 0.317 μg/l. The highest quantified median and 95th percentile concentrations of BPA in Asian drinking water are 0.026 μg/l and 0.19 μg/l, while high detection limits restricted the determination of representative median and 95th percentile concentrations in North America and Europe. BPA in drinking water represents a minor component of overall human exposure, and compared with the lowest available oral toxicity benchmark of 16 μg/kg-bw/day (includes an uncertainty factor of 300) gives margins of safety >1100. Human biomonitoring data indicate that ingestion of drinking water represents <2.8% of the total intake of BPA.
Measurement of radon progenies using the Timepix detector.
Bulanek, Boris; Jilek, Karel; Cermak, Pavel
2014-07-01
After an introduction of Timepix detector, results of these detectors with silicon and cadmium telluride detection layer in assessment of activity of short-lived radon decay products are presented. They were collected on an open-face filter by means of one-grab sampling method from the NRPI radon chamber. Activity of short-lived radon decay products was estimated from measured alpha decays of 218,214Po. The results indicate very good agreement between the use of both Timepix detectors and an NRPI reference instrument, continuous monitor Fritra 4. Low-level detection limit for EEC was estimated to be 41 Bq m(-3) for silicon detection layer and 184 Bq m(-3) for CdTe detection layer, respectively. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Yi, Rongxing; Yang, Xinyan; Zhou, Ran; Li, Jiaming; Yu, Huiwu; Hao, Zhongqi; Guo, Lianbo; Li, Xiangyou; Lu, Yongfeng; Zeng, Xiaoyan
2018-05-18
To detect available heavy metals in soil using laser-induced breakdown spectroscopy (LIBS) and improve its poor detection sensitivity, a simple and low cost sample pretreatment method named solid-liquid-solid transformation was proposed. By this method, available heavy metals were extracted from soil through ultrasonic vibration and centrifuging and then deposited on a glass slide. Utilization of this solid-liquid-solid transformation method, available Cd and Pb elements in soil were detected successfully. The results show that the regression coefficients of calibration curves for soil analyses reach to more than 0.98. The limits of detection could reach to 0.067 and 0.94 ppm for available Cd and Pb elements in soil under optimized conditions, respectively, which are much better than those obtained by conventional LIBS.
Assessment of probability of detection of delaminations in fiber-reinforced composites
NASA Technical Reports Server (NTRS)
Chern, E. J.; Chu, H. P.; Yang, J. N.
1991-01-01
Delamination is one of the critical defects in composite materials and structures. An ultrasonic C-scan imaging technique which maps out the acoustic impedance mismatched areas with respect to the sample coordinates, is particularly well suited for detecting and characterizing delaminations in composites. To properly interpret the results, it is necessary to correlate the indications with the detection limits and probability of detection (POD) of the ultrasonic C-scan imaging technique. The baseline information on the assessment of POD of delaminations in composite materials and structures is very beneficial to the evaluation of spacecraft materials. In this study, we review the principle of POD, describe the laboratory set-up and procedure, and present the experimental results as well as assessment of POD of delaminations in fiber reinforced composite panels using ultrasonic C-scan techniques.
NASA Astrophysics Data System (ADS)
Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.
2017-02-01
A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.
Li, Peng; Jia, Junwei; Bai, Lan; Pan, Aihu; Tang, Xueming
2013-07-01
Genetically modified carnation (Dianthus caryophyllus L.) Moonshade was approved for planting and commercialization in several countries from 2004. Developing methods for analyzing Moonshade is necessary for implementing genetically modified organism labeling regulations. In this study, the 5'-transgene integration sequence was isolated using thermal asymmetric interlaced (TAIL)-PCR. Based upon the 5'-transgene integration sequence, conventional and TaqMan real-time PCR assays were established. The relative limit of detection for the conventional PCR assay was 0.05 % for Moonshade using 100 ng total carnation genomic DNA, corresponding to approximately 79 copies of the carnation haploid genome, and the limits of detection and quantification of the TaqMan real-time PCR assay were estimated to be 51 and 254 copies of haploid carnation genomic DNA, respectively. These results are useful for identifying and quantifying Moonshade and its derivatives.
Acharya, U Rajendra; Oh, Shu Lih; Hagiwara, Yuki; Tan, Jen Hong; Adeli, Hojjat
2017-09-27
An encephalogram (EEG) is a commonly used ancillary test to aide in the diagnosis of epilepsy. The EEG signal contains information about the electrical activity of the brain. Traditionally, neurologists employ direct visual inspection to identify epileptiform abnormalities. This technique can be time-consuming, limited by technical artifact, provides variable results secondary to reader expertise level, and is limited in identifying abnormalities. Therefore, it is essential to develop a computer-aided diagnosis (CAD) system to automatically distinguish the class of these EEG signals using machine learning techniques. This is the first study to employ the convolutional neural network (CNN) for analysis of EEG signals. In this work, a 13-layer deep convolutional neural network (CNN) algorithm is implemented to detect normal, preictal, and seizure classes. The proposed technique achieved an accuracy, specificity, and sensitivity of 88.67%, 90.00% and 95.00%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Copernicus observational searches for OH and H/sub 2/O in diffuse clouds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, W.H.; Snow, T.P. Jr.
1979-03-01
An intensive search for OH and H/sub 2/O in the directions of sigma Sco, ..cap alpha.. Cam, and omicron Per was undertaken with the Copernicus satellite. Multiple scans were carried out over the wavelength region for the expected absorption features due to the OH D--X and H/sub 2/O C--X transitions. The feature due to OH was possibly detected toward sigma Sco, and only an upper limit can be given toward ..cap alpha.. Cam. H/sub 2/O was not detected in any of the stars at the signal level accumulated. The OH abundance toward sigma Sco and the respective lower limits formore » the OH/H/sub 2/O ratios are discussed with regard to the extant models for the steady-state abundances of OH and H/sub 2/O, and shown not to be inconsistent with ion-molecule schemes.« less
Dalkıran, Berna; Erden, Pınar Esra; Kılıç, Esma
2016-06-01
In this study, two enzyme electrodes based on graphene (GR), Co3O4 nanoparticles and chitosan (CS) or multi-walled carbon nanotubes (MWCNTs), Co3O4 nanoparticles, and CS, were fabricated as novel biosensing platforms for galactose determination, and their performances were compared. Galactose oxidase (GaOx) was immobilized onto the electrode surfaces by crosslinking with glutaraldehyde. Optimum working conditions of the biosensors were investigated and the analytical performance of the biosensors was compared with respect to detection limit, linearity, repeatability, and stability. The MWCNTs-based galactose biosensor provided about 1.6-fold higher sensitivity than its graphene counterpart. Moreover, the linear working range and detection limit of the MWCNTs-based galactose biosensor was superior to the graphene-modified biosensor. The successful application of the purposed biosensors for galactose biosensing in human serum samples was also investigated.
Gong, Zhen-bin; Liang, Feng; Yang, Peng-yuan; Jin, Qin-han; Huang, Ben-li
2002-02-01
A system of atomic and ionic fluorescence spectrometry in microwave plasma torch (MPT) discharge excited by high current microsecond pulsed hollow cathode lamp (HCMP HCL) has been developed. The operation conditions for Ca atomic and ionic fluorescence spectrometry have been optimized. Compared with atomic fluorescence spectrometry (AFS) in argon microwave induced plasma (MIP) and MPT with the excitation of direct current and conventional pulsed HCL, the system with HCMP HCL excitation can improve AFS and ionic fluorescence spectrometry (IFS) detection limits in MPT atomizer and ionizer. Detection limits (3 sigma) with HCMP HCL-MPT-AFS/IFS are 10.1 ng.mL-1 for Ca I 422.7 nm, 14.6 ng.mL-1 for Ca II 393.4 nm, and 37.4 ng.mL-1 for Ca II 396.8 nm, respectively.
High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.
Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M
2003-10-25
An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.
Cembrowski, G S; Hackney, J R; Carey, N
1993-04-01
The Clinical Laboratory Improvement Act of 1988 (CLIA 88) has dramatically changed proficiency testing (PT) practices having mandated (1) satisfactory PT for certain analytes as a condition of laboratory operation, (2) fixed PT limits for many of these "regulated" analytes, and (3) an increased number of PT specimens (n = 5) for each testing cycle. For many of these analytes, the fixed limits are much broader than the previously employed Standard Deviation Index (SDI) criteria. Paradoxically, there may be less incentive to identify and evaluate analytically significant outliers to improve the analytical process. Previously described "control rules" to evaluate these PT results are unworkable as they consider only two or three results. We used Monte Carlo simulations of Kodak Ektachem analyzers participating in PT to determine optimal control rules for the identification of PT results that are inconsistent with those from other laboratories using the same methods. The analysis of three representative analytes, potassium, creatine kinase, and iron was simulated with varying intrainstrument and interinstrument standard deviations (si and sg, respectively) obtained from the College of American Pathologists (Northfield, Ill) Quality Assurance Services data and Proficiency Test data, respectively. Analytical errors were simulated in each of the analytes and evaluated in terms of multiples of the interlaboratory SDI. Simple control rules for detecting systematic and random error were evaluated with power function graphs, graphs of probability of error detected vs magnitude of error. Based on the simulation results, we recommend screening all analytes for the occurrence of two or more observations exceeding the same +/- 1 SDI limit. For any analyte satisfying this condition, the mean of the observations should be calculated. For analytes with sg/si ratios between 1.0 and 1.5, a significant systematic error is signaled by the mean exceeding 1.0 SDI. Significant random error is signaled by one observation exceeding the +/- 3-SDI limit or the range of the observations exceeding 4 SDIs. For analytes with higher sg/si, significant systematic or random error is signaled by violation of the screening rule (having at least two observations exceeding the same +/- 1 SDI limit). Random error can also be signaled by one observation exceeding the +/- 1.5-SDI limit or the range of the observations exceeding 3 SDIs. We present a practical approach to the workup of apparent PT errors.
Settypalli, Tirumala Bharani Kumar; Lamien, Charles Euloge; Spergser, Joachim; Lelenta, Mamadou; Wade, Abel; Gelaye, Esayas; Loitsch, Angelika; Minoungou, Germaine; Thiaucourt, Francois; Diallo, Adama
2016-01-01
Respiratory infections, although showing common clinical symptoms like pneumonia, are caused by bacterial, viral or parasitic agents. These are often reported in sheep and goats populations and cause huge economic losses to the animal owners in developing countries. Detection of these diseases is routinely done using ELISA or microbiological methods which are being reinforced or replaced by molecular based detection methods including multiplex assays, where detection of different pathogens is carried out in a single reaction. In the present study, a one-step multiplex RT-qPCR assay was developed for simultaneous detection of Capripoxvirus (CaPV), Peste de petits ruminants virus (PPRV), Pasteurella multocida (PM) and Mycoplasma capricolum ssp. capripneumonia (Mccp) in pathological samples collected from small ruminants with respiratory disease symptoms. The test performed efficiently without any cross-amplification. The multiplex PCR efficiency was 98.31%, 95.48%, 102.77% and 91.46% whereas the singleplex efficiency was 93.43%, 98.82%, 102.55% and 92.0% for CaPV, PPRV, PM and Mccp, respectively. The correlation coefficient was greater than 0.99 for all the targets in both multiplex and singleplex. Based on cycle threshold values, intra and inter assay variability, ranged between the limits of 2%-4%, except for lower concentrations of Mccp. The detection limits at 95% confidence interval (CI) were 12, 163, 13 and 23 copies/reaction for CaPV, PPRV, PM and Mccp, respectively. The multiplex assay was able to detect CaPVs from all genotypes, PPRV from the four lineages, PM and Mccp without amplifying the other subspecies of mycoplasmas. The discriminating power of the assay was proven by accurate detection of the targeted pathogen (s) by screening 58 viral and bacterial isolates representing all four targeted pathogens. Furthermore, by screening 81 pathological samples collected from small ruminants showing respiratory disease symptoms, CaPV was detected in 17 samples, PPRV in 45, and PM in six samples. In addition, three samples showed a co-infection of PPRV and PM. Overall, the one-step multiplex RT-qPCR assay developed will be a valuable tool for rapid detection of individual and co-infections of the targeted pathogens with high specificity and sensitivity.
Chatterjee, Arnab; Kumar, Satyanshu; Chattopadhyay, Sunil K
2013-12-01
A simple, rapid, accurate and reproducible reverse-phase HPLC method has been developed for the identification and quantification of two alkaloids ephedrine and cryptolepine in different extracts of Sida species using photodiode array detection. Baseline separation of the two alkaloids was achieved on a Waters RP-18 X-terra column (250 × 4.6 mm, 5 µm) using a solvent system consisting of a mixture of water containing 0.1% Trifluoroacetic acid (TFA) and acetonitrile in a gradient elution mode with detection at 210 and 280 nm for ephedrine and cryptolepine, respectively. The calibration curves were linear in a concentration range of 10-250 µg/mL for both the alkaloids with correlation coefficient values >0.99. The limits of detection and quantification for ephedrine and cryptolepine were 5 and 10 µg/mL and 2.5 and 5 µg/mL, respectively. Relative standard deviation values for intra-day and inter-day precision were 1.22 and 1.04% for ephedrine and 1.71 and 2.06% for cryptolepine, respectively. Analytical recovery ranged from 92.46 to 103.95%. The developed HPLC method was applied to identify and quantify ephedrine and cryptolepine in different extracts of Sida species. Copyright © 2013 John Wiley & Sons, Ltd.
Tabaraki, Reza; Abdi, Omran; Yousefipour, Sedigheh
2017-03-01
A green and simple microwave-assisted method was used to synthesis water-soluble boron and nitrogen-co-doped carbon dots (B-N-CDs). These B-N-CDs were successfully used for the fluorescent determination of Sn 4+ and Mo 6+ ions. This probe had a fast response time at pH = 4 with high sensitivity and selectivity. Linear correlation between F 0 /F and the concentration was seen in the range of 0.2-18 μM and 0.2-25 μM for Sn 4+ and Mo 6+ , respectively. Under optimum condition, the limit of detection (LOD) for Sn 4+ and Mo 6+ were 150 nM and 132 nM, respectively. The performance of the sensor was evaluated by different real samples such as tap, river and mineral water, canned fish sample and tomato samples.
Evaluation of Various Depainting Processes on Mechanical Properties of 2024-T3 Aluminum Substrate
NASA Technical Reports Server (NTRS)
McGill, P.
2001-01-01
Alternate alkaline and neutral chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. These chemicals also, in general, meet corrosion acceptance criteria as specified in SAE MA 4872. Alternate acid chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. However, these chemicals do not generally meet corrosion acceptance criteria as specified in SAE MA 4872, especially in the areas of non-clad material performance and hydrogen embrittlement. Media blast methods reviewed in the study do not, in general, adversely affect fatigue performance or crack detectability of 2024-T3 substrate. Sodium bicarbonate stripping exhibited a tendency towards inhibiting crack detectability. These generalizations are based on a limited sample size and additional testing should be performed to characterize the response of specific substrates to specific processes.
Magnuson, M L; Creed, J T; Brockhoff, C A
1997-10-01
Capillary electrophoresis (CE) with hydride generation inductively coupled plasma mass spectrometry was used to determine four arsenicals and two selenium species. Selenate (SeVI) was reduced on-line to selenite (SeIV) by mixing the CE effluent with concentrated HCl. A microporous PTFE tube was used as a gas-liquid separator to eliminate the 40Ar37Cl and 40Ar35Cl interference from 77Se and 75As, respectively. The direction of the electroosmotic flow during CE was reversed with hydrodynamic pressure, which allowed increased freedom of buffer choice. For conventional pressure injection, method detection limits for SeIV and SeVI based on seven replicate injections were 10 and 24 pg, respectively. Recoveries of SeIV and SeVI in drinking water were measured.
Ramey, Andy M.; Spackman, Erica; Yeh, Jung-Yong; Fujita, Go; Konishi, Kan; Reed, John A.; Wilcox, Benjamin R.; Brown, Justin D.; Stallknecht, David E.
2013-01-01
Blood samples from 105 northern pintails (Anas acuta) captured on Hokkaido, Japan were tested for antibodies to avian influenza virus (AIV), Japanese encephalitis virus (JEV), and West Nile virus (WNV) to assess possible involvement of this species in the spread of economically important and potentially zoonotic pathogens. Antibodies to AIV were detected in 64 of 105 samples (61%). Of the 64 positives, 95% and 81% inhibited agglutination of two different H5 AIV antigens (H5N1 and H5N9), respectively. Antibodies to JEV and WNV were detected in five (5%) and none of the samples, respectively. Results provide evidence for prior exposure of migrating northern pintails to H5 AIV which couldhave implications for viral shedding and disease occurrence. Results also provide evidence for limited involvement of this species in the transmission and spread of flaviviruses during spring migration.
Synthesis and application of acrylamide-maleic anhydride copolymer for solid phase extraction
NASA Astrophysics Data System (ADS)
Teng, Xiaoxiao; Niu, Yabo; Xie, Zhihai; Cai, Qing
2018-03-01
A new absorbent of acrylamide-maleic anhydride copolymer (PAMMA) for preconcentration of metal ions was synthesized. This PAMMA was applied for enrichment and determination of Al3+, Cu2+, Cd2+ and Pb2+ in table salt by ICP-OES. The maximum uptake capacities of PAMMA were 6.49, 5.84, 5.34 and 7.49 mg g‑1 for Al3+, Cu2+, Cd2+ and Pb2+, respectively. The limit of detection was 0.31, 0.26, 0.43, and 0.12 μg L‑1, and the RSD (relative standard deviations, n=6) was 1.5%, 3.7%, 3.0% and 2.6% for Al3+, Cu2+, Cd2+ and Pb2+, respectively. The presented method was used for simultaneous detecting of Al3+, Cu2+, Cd2+ and Pb2+ in table salt with the recoveries from 95.0% to 103%.
Dash, K; Thangavel, S; Krishnamurthy, N V; Rao, S V; Karunasagar, D; Arunachalam, J
2005-04-01
The speciation and determination of sulfate (SO4(2-)) and elemental sulfur (S degree) in zinc sulfide (ZnS) using ion-chromatography (IC) and reversed-phase liquid chromatography (RPLC) respectively is described. Three sample pretreatment approaches were employed with the aim of determining sulfate: (i) conventional water extraction of the analyte; (ii) solid-liquid aqueous extraction with an ultrasonic probe; and (iii) elimination of the zinc sulfide matrix via ion-exchange dissolution (IED). The separation of sulfate was carried out by an anion-exchange column (IonPac AS17), followed by suppressed conductivity detection. Elemental sulfur was extracted ultrasonically from the acid treated sample solution into chloroform and separated on a reversed phase HPLC column equipped with a diode array detector (DAD) at 264 nm. The achievable solid detection limits for sulfate and sulfur were 35 and 10 microg g(-1) respectively.
NASA Astrophysics Data System (ADS)
Azab, Hassan A.; Khairy, Gasser M.; Kamel, Rasha M.
2015-09-01
This work describes the application of time resolved fluorescence in microtiter plates for investigating the interactions of europium-allyl-3-carboxycoumarin with pesticides chlorpyrifos, endosulfan and crotoxyphos. Stern-Volmer studies at different temperatures for chlorpyrifos and crotoxyphos shows dynamic and static quenching mechanisms respectively. Direct methods for the determination of the pesticides under investigation have been developed using the luminescence variations of the probe in solution. The detection limits are 6.53, 0.004, 3.72 μmol/L for chlorpyrifos, endosulfan, and crotoxyphos, respectively. The binding constants and thermodynamic parameters of the pesticides with probe were evaluated. A thermodynamic analysis showed that the reaction is spontaneous with negative ΔG. Effect of some relevant interferents on the detection of pesticides has been investigated. The new method was applied to the determination of the pesticides in different types of water samples (tap, mineral, and waste water).
Kadavilpparampu, Afsal Mohammed; Al Lawati, Haider A J; Suliman, Fakhr Eldin O
2017-08-05
For the first time, the analytical figures of merit in detection capabilities of the very less explored photoinduced chemical oxidation method for Ru(bpy) 3 2+ CL has been investigated in detail using 32 structurally different analytes. It was carried out on-chip using peroxydisulphate and visible light and compared with well-known direct chemical oxidation approaches using Ce(IV). The analytes belong to various chemical classes such as tertiary amine, secondary amine, sulphonamide, betalactam, thiol and benzothiadiazine. Influence of detection environment on CL emission with respect to method of oxidation was evaluated by changing the buffers and pH. The photoinduced chemical oxidation exhibited more universal nature for Ru(bpy) 3 2+ CL in detection towards selected analytes. No additional enhancers, reagents, or modification in instrumental configuration were required. Wide detectability and enhanced emission has been observed for analytes from all the chemical classes when photoinduced chemical oxidation was employed. Some of these analytes are reported for the first time under photoinduced chemical oxidation like compounds from sulphonamide, betalactam, thiol and benzothiadiazine class. On the other hand, many of the selected analytes including tertiary and secondary amines such as cetirizine, azithromycin fexofenadine and proline did not produced any analytically useful CL signal (S/N=3 or above for 1μgmL -1 analyte) under chemical oxidation. The most fascinating observations was in the detection limits; for example ofloxacin was 15 times more intense with a detection limit of 5.81×10 -10 M compared to most lowest ever reported 6×10 -9 M. Earlier, penicillamine was detected at 0.1μgmL -1 after derivatization using photoinduced chemical oxidation, but in this study, we improved it to 5.82ngmL -1 without any prior derivatization. The detection limits of many other analytes were also found to be improved by several orders of magnitude under photoinduced chemical oxidation. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kadavilpparampu, Afsal Mohammed; Al Lawati, Haider A. J.; Suliman, Fakhr Eldin O.
2017-08-01
For the first time, the analytical figures of merit in detection capabilities of the very less explored photoinduced chemical oxidation method for Ru(bpy)32 + CL has been investigated in detail using 32 structurally different analytes. It was carried out on-chip using peroxydisulphate and visible light and compared with well-known direct chemical oxidation approaches using Ce(IV). The analytes belong to various chemical classes such as tertiary amine, secondary amine, sulphonamide, betalactam, thiol and benzothiadiazine. Influence of detection environment on CL emission with respect to method of oxidation was evaluated by changing the buffers and pH. The photoinduced chemical oxidation exhibited more universal nature for Ru(bpy)32 + CL in detection towards selected analytes. No additional enhancers, reagents, or modification in instrumental configuration were required. Wide detectability and enhanced emission has been observed for analytes from all the chemical classes when photoinduced chemical oxidation was employed. Some of these analytes are reported for the first time under photoinduced chemical oxidation like compounds from sulphonamide, betalactam, thiol and benzothiadiazine class. On the other hand, many of the selected analytes including tertiary and secondary amines such as cetirizine, azithromycin fexofenadine and proline did not produced any analytically useful CL signal (S/N = 3 or above for 1 μgmL- 1 analyte) under chemical oxidation. The most fascinating observations was in the detection limits; for example ofloxacin was 15 times more intense with a detection limit of 5.81 × 10- 10 M compared to most lowest ever reported 6 × 10- 9 M. Earlier, penicillamine was detected at 0.1 μg mL- 1 after derivatization using photoinduced chemical oxidation, but in this study, we improved it to 5.82 ng mL- 1 without any prior derivatization. The detection limits of many other analytes were also found to be improved by several orders of magnitude under photoinduced chemical oxidation.
Jiang, Qikun; Liu, Wanjun; Li, Xiaoting; Zhang, Tianhong; Wang, Yongjun; Liu, Xiaohong
2016-01-01
Supercritical fluid chromatography with tandem mass spectrometry was used to comprehensively profile polyene phosphatidyl choline (PPC) extracted from soybean. We achieved an efficient chromatographic analysis using a BEH-2EP column (3 × 100 mm(2) , 1.7 μm) with a mobile phase consisting of CO2 and a cosolvent in gradient combination at a flow rate of 1.0 mL/min. The cosolvent consisted of methanol, acetonitrile, and water (containing 10 mM ammonium acetate and 0.2% formic acid). The total single-run time was 7 min. We used this method to accurately detect ten different phospholipids (PLs) during extraction. The limits of quantification for phosphatidyl choline, lyso-phosphatidylcholine (LPC), phosphatidic acid (PA), sphingomyelin, phosphatidyl glycerol, phosphatidyl inositol (PI), cholesterol, cardiolipin, phosphatidyl serine, and phosphatidyl ethanolamine (PE) were 20.6, 19.52, 1.21, 2.38, 0.50, 2.28, 54.3, 0.60, 0.65, and 4.85 ng/mL, respectively. However, adopting the high-performance liquid chromatography with evaporative light scattering detection method issued by the China Food and Drug Administration, only PA, LPC, PE, PI, and PPC could be analyzed accurately, and the limits of quantification were 33.89, 60.5, 30.3, 10.9, and 61.79 μg/mL, respectively. The total single-run time was at the least 20 min. Consequently, the supercritical fluid chromatography with tandem mass spectrometry method was more suitable for the analysis of related PLs. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ryu, Hodon; Alum, Absar; Alvarez, Maria; Mendoza, Jose; Abbaszadegan, Morteza
2005-06-01
Increased reliance of urban populations on Rio Grande water has necessitated an expanded microbial surveillance of the river to help identify and evaluate sources of human pathogens, which could pose a public health risk. The objectives of this study were to investigate microbial and chemical water quality in Rio Grande water and to perform risk assessment analyses for Cryptosporidium. No oocysts in any of the ten-litre samples were detected. However, the limit of detection in the water samples ranged between 20 and 200 oocysts/100 L. The limits of detection obtained in this study would result in one to two orders of magnitude higher risk of infection for Cryptosporidium than the U.S.EPA annual acceptable risk level of 10(-4). The bacterial data showed the significance of animal farming and raw sewage as sources of fecal pollution. Male specific and somatic coliphages were detected in 52% (11/21) and 62% (24/39) of the samples, respectively. Somatic coliphages were greater by one order of magnitude, and were better correlated with total (r2 = 0.6801; p < or = 0.05) and fecal coliform bacteria (r2 = 0.7366; p < or = 0.05) than male specific coliphages. The dissolved organic carbon (DOC) and specific ultraviolet absorbance (SUVA) values ranged 2.58-5.59mg/L and 1.23-2.29 m(-1) (mg/I)(-1), respectively. Low SUVA values of raw water condition make it difficult to remove DOC during physical and chemical treatment processes. The microbial and chemical data provided from this study can help drinking water utilities to maintain balance between greater microbial inactivation and reduced disinfection by-products (DBPs) formation.
Lu, Li-Min; Zhang, Xiao-Bing; Kong, Rong-Mei; Yang, Bin; Tan, Weihong
2011-08-03
Many types of fluorescent sensing systems have been reported for biological small molecules. Particularly, several methods have been developed for the recognition of ATP or NAD(+), but they only show moderate sensitivity, and they cannot discriminate either ATP or NAD(+) from their respective analogues. We have addressed these limitations and report here a dual strategy which combines split DNAzyme-based background reduction with catalytic and molecular beacon (CAMB)-based amplified detection to develop a ligation-triggered DNAzyme cascade, resulting in ultrahigh sensitivity. First, the 8-17 DNAzyme is split into two separate oligonucleotide fragments as the building blocks for the DNA ligation reaction, thereby providing a zero-background signal to improve overall sensitivity. Next, a CAMB strategy is further employed for amplified signal detection achieved through cycling and regenerating the DNAzyme to realize the true enzymatic multiple turnover (one enzyme catalyzes the cleavage of several substrates) of catalytic beacons. This combination of zero-background signal and signal amplification significantly improves the sensitivity of the sensing systems, resulting in detection limits of 100 and 50 pM for ATP and NAD(+), respectively, much lower than those of previously reported biosensors. Moreover, by taking advantage of the highly specific biomolecule-dependence of the DNA ligation reaction, the developed DNAzyme cascades show significantly high selectivity toward the target cofactor (ATP or NAD(+)), and the target biological small molecule can be distinguished from its analogues. Therefore, as a new and universal platform for the design of DNA ligation reaction-based sensing systems, this novel ligation-triggered DNAzyme cascade method may find a broad spectrum of applications in both environmental and biomedical fields.
Detection of tire tread particles using laser-induced breakdown spectroscopy
NASA Astrophysics Data System (ADS)
Prochazka, David; Bilík, Martin; Prochazková, Petra; Klus, Jakub; Pořízka, Pavel; Novotný, Jan; Novotný, Karel; Ticová, Barbora; Bradáč, Albert; Semela, Marek; Kaiser, Jozef
2015-06-01
The objective of this paper is a study of the potential of laser induced breakdown spectroscopy (LIBS) for detection of tire tread particles. Tire tread particles may represent pollutants; simultaneously, it is potentially possible to exploit detection of tire tread particles for identification of optically imperceptible braking tracks at locations of road accidents. The paper describes the general composition of tire treads and selection of an element suitable for detection using the LIBS method. Subsequently, the applicable spectral line is selected considering interferences with lines of elements that might be present together with the detected particles, and optimization of measurement parameters such as incident laser energy, gate delay and gate width is performed. In order to eliminate the matrix effect, measurements were performed using 4 types of tires manufactured by 3 different producers. An adhesive tape was used as a sample carrier. The most suitable adhesive tape was selected from 5 commonly available tapes, on the basis of their respective LIBS spectra. Calibration standards, i.e. an adhesive tape with different area content of tire tread particles, were prepared for the selected tire. A calibration line was created on the basis of the aforementioned calibration standards. The linear section of this line was used for determination of the detection limit value applicable to the selected tire. Considering the insignificant influence of matrix of various types of tires, it is possible to make a simple recalculation of the detection limit value on the basis of zinc content in a specific tire.
Maeda, Hiroshi; Kokeguchi, Susumu; Fujimoto, Chiyo; Tanimoto, Ichiro; Yoshizumi, Wakako; Nishimura, Fusanori; Takashiba, Shogo
2005-02-01
A method for nucleic acid amplification, loop-mediated isothermal amplification (LAMP) was employed to develop a rapid and simple detection system for periodontal pathogen, Porphyromonas gingivalis. A set of six primers was designed by targeting the 16S ribosomal RNA gene. By the detection system, target DNA was amplified and visualized on agarose gel within 30 min under isothermal condition at 64 degrees C with a detection limit of 20 cells of P. gingivalis. Without gel electrophoresis, the LAMP amplicon was directly visualized in the reaction tube by addition of SYBR Green I for a naked-eye inspection. The LAMP reaction was also assessed by white turbidity of magnesium pyrophosphate (a by-product of LAMP) in the tube. Detection limits of these naked-eye inspections were 20 cells and 200 cells, respectively. Although false-positive DNA amplification was observed from more than 10(7) cells of Porphyromonas endodontalis, no amplification was observed in other five related oral pathogens. Further, quantitative detection of P. gingivalis was accomplished by a real-time monitoring of the LAMP reaction using SYBR Green I with linearity over a range of 10(2)-10(6) cells. The real-time LAMP was then applied to clinical samples of dental plaque and demonstrated almost identical results to the conventional real-time PCR with an advantage of rapidity. These findings indicate the potential usefulness of LAMP for detecting and quantifying P. gingivalis, especially in its rapidity and simplicity.
Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina
2014-01-01
A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform + acetone + ammonia (25%) in volume composition 8 : 2 : 0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75 ÷ 12.50 μg·spot−1, and from 1.00 ÷ 2.50 μg·spot−1 for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot−1 and LOD is 0.066 μg·spot−1. LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot−1, respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia. PMID:24526880
Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina
2014-01-01
A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform+acetone+ammonia (25%) in volume composition 8:2:0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75÷12.50 μg·spot(-1), and from 1.00÷2.50 μg·spot(-1) for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot(-1) and LOD is 0.066 μg·spot(-1). LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot(-1), respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia.
Pyun, Chang-Won; Abd El-Aty, A M; Hashim, M M M; Shim, Jae-Han; Lee, Si-Kyung; Choi, Kang-Duk; Park, Kwan-Ha; Shin, Ho-Chul; Lee, Chiho
2008-03-01
A solid-phase fluorescence immunoassay (SPFIA) that was primarily developed for detection of antibiotic residues in milk was qualitatively applied for the pre-screening of the residues of aminoglycoside antibiotics, streptomycin and dihydrostreptomycin, in meat press juice. The confirmation of both analytes was performed using a validated method of highperformance liquid chromatography with post-column derivatization. The analytical performance was demonstrated by the analysis of pork meat samples spiked at three concentration levels, ranging from 0.25 to 2.5 ppm for each analyte. In general, the recoveries ranged from 80.4 to 81.5% and from 79.6 to 84.4% for streptomycin and dihydrostreptomycin, respectively, with relative standard deviations lower than 6%. The limits of detection were 0.1 and 0.15 ppm for streptomycin and dihydrostreptomycin, respectively, and the limits of quantification of 0.35 and 0.5 ppm are below the maximum residue limits of Codex, the European Union, and the Korean Food and Drug Administration (ranging from 0.5 to 0.6 ppm). Eight real samples collected from the Seoul area were first monitored using SPFIA, and none of them were found positive. These findings are in good accordance with those observed by HPLC analysis. To the best of our knowledge, this is the first report to monitor the aminoglycoside residues in pork meat press juice using SPFIA.
Li, Zheng; Wang, Yijing; Liu, Ying; Zeng, Yongyi; Huang, Aimin; Peng, Niancai; Liu, Xiaolong; Liu, Jingfeng
2013-09-07
We designed a novel aptamer based biosensor (aptasensor) for ultrasensitive detection of adenosine triphosphate (ATP) through resonance energy transfer (RET). The ATP aptamer was modified with Cy3 at the 3' end, and a green quantum dot (525) was attached to the 5' end of its complementary sequence respectively. The ATP aptamer and its complementary sequence could assemble into a duplex structure in the absence of target ATP, and then decrease the distance between the quantum dot and Cy3 which could produce significant RET signal. Upon ATP binding, the ATP aptamer could dissociate with its complementary sequence and then increase the distance between the quantum dot and Cy3 which would significantly decrease the RET signal. Therefore, the ATP detection could be easily achieved through detection of the fluorescence intensity ratio between 525 nm and 560 nm. The results show that the emission fluorescence intensity ratio of 525/560 is linearly related to the logarithmic concentration of ATP. The linear range of this aptasensor is from 0.1 nM to 1 μM, and the detection limit is lower down to 0.01 nM. Excellent selectivity of this aptasensor for ATP has been demonstrated through the detection of thymidine triphosphate (TTP), cytidine triphosphate (CTP), guanosine triphosphate (GTP) and adenosine diphosphate (ADP) respectively as control. The method we described here could easily detect ATP with excellent selectivity, linearity and sensitivity down to the nanomolar range, as well as avoid photobleaching.
Carpenter, Tim E; O'Brien, Joshua M; Hagerman, Amy D; McCarl, Bruce A
2011-01-01
The epidemic and economic impacts of Foot-and-mouth disease virus (FMDV) spread and control were examined by using epidemic simulation and economic (epinomic) optimization models. The simulated index herd was a ≥2,000 cow dairy located in California. Simulated disease spread was limited to California; however, economic impact was assessed throughout the United States and included international trade effects. Five index case detection delays were examined, which ranged from 7 to 22 days. The simulated median number of infected premises (IP) ranged from approximately 15 to 745, increasing as the detection delay increased from 7 to 22 days. Similarly, the median number of herds under quarantine increased from approximately 680 to 6,200, whereas animals slaughtered went from approximately 8,700 to 260,400 for detection delays of 7-22 days, respectively. The median economic impact of an FMD outbreak in California was estimated to result in national agriculture welfare losses of $2.3-$69.0 billion as detection delay increased from 7 to 22 days, respectively. If assuming a detection delay of 21 days, it was estimated that, for every additional hr of delay, the impact would be an additional approximately 2,000 animals slaughtered and an additional economic loss of $565 million. These findings underline the critical importance that the United States has an effective early detection system in place before an introduction of FMDV if it hopes to avoid dramatic losses to both livestock and the economy.
Orlando, James L.; McWayne, Megan; Sanders, Corey; Hladik, Michelle
2013-01-01
Surface-water samples were collected from sites within the Sacramento-San Joaquin Delta and Grizzly Bay, California, during the spring in 2011 and 2012, and they were analyzed by the U.S. Geological Survey for a suite of 99 current-use pesticides and pesticide degradates. Samples were collected and analyzed as part of a collaborative project studying the occurrence and characteristics of phytoplankton in the San Francisco Estuary. Samples were analyzed by two separate laboratory methods employing gas chromatography/mass spectrometry or liquid chromatography with tandem mass spectrometry. Method detection limits ranged from 0.9 to 10.5 nanograms per liter (ng/L). Eighteen pesticides were detected in samples collected during 2011, and the most frequently detected compounds were the herbicides clomazone, diuron, hexazinone and metolachlor, and the diuron degradates 3,4-dichloroaniline and N-(3,4-dichlorophenyl)-N’-methylurea (DCPMU). Concentrations for all compounds were less than 75 ng/L, except for the rice herbicide clomazone and the fungicide tetraconazole, which had maximum concentrations of 535 and 511 ng/L, respectively. In samples collected in 2012, a total of 16 pesticides were detected. The most frequently detected compounds were the fungicides azoxystrobin and boscalid and the herbicides diuron, hexazinone, metolachlor, and simazine. Maximum concentrations for all compounds detected in 2012 were less than 75 ng/L, except for the fungicide azoxystrobin and the herbicides hexazinone and simazine, which were detected at up to 188, 134, and 140 ng/L, respectively.
Jain, P S; Patel, M K; Gorle, A P; Chaudhari, A J; Surana, S J
2012-09-01
A simple, specific, accurate and precise stability-indicating reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of olmesartan medoxomile (OLME), amlodipine besylate (AMLO) and hydrochlorothiazide (HCTZ) in tablet dosage form. The method was developed using an RP C18 base deactivated silica column (250 × 4.6 mm, 5 µm) with a mobile phase consisting of triethylamine (pH 3.0) adjusted with orthophosphoric acid (A) and acetonitrile (B), with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 mL/min. Ultraviolet detection was used at 236 nm. The retention times for OLME, AMLO and HCTZ were found to be 6.72, 4.28 and 2.30, respectively. The proposed method was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curves of OLME, AMLO and HCTZ were linear over the range of 50-150, 12.5-37.5 and 31-93 µg/mL, respectively. The method was found to be sensitive. The limits of detection of OLME, AMLO and HCTZ were determined 0.19, 0.16 and 0.22 µg/mL and limits of quantification of OLME, AMLO and HCTZ were determined 0.57, 0.49 and 0.66, respectively. Forced degradation study was performed according to International Conference on Harmonization guidelines.
He, Yufei; Li, Qing; Bi, Kaishun
2015-04-01
To control the quality of Rhizoma Chuanxiong, a method based on high-performance liquid chromatography method coupled with diode array detection was developed for the quantitative analysis of six active ingredients using a single standard to determine multi-components and chemical fingerprint analysis for the first time. The separation was performed on an Agilent Zorbax SB-C18 column by gradient elution with methanol and aqueous phase (containing 0.5% glacial acetic acid) at a flow rate of 1.0 mL/min. The UV wavelength was set at 274 nm. This assay was fully validated with respect to precision, repeatability, and accuracy. All calibration curves showed good linearity (R(2) > 0.9994) within test ranges. The limit of detection and limit of quantification were lower than 0.01 and 0.03 μg/mL, respectively. The relative standard deviation for repeatability and the intermediate precision of six analytes were less than 1.6 and 2.5%, respectively, the overall recovery was 96.1-103.1%. In addition, fingerprint chromatography using hierarchical clustering analysis and similarity analysis was performed to differentiate and classify the samples. The method described here could provide a more comprehensive and reasonable scientific assessment of the quality of Rhizoma Chuanxiong. Therefore, the strategy is feasible, credible, and is easily and effectively adapted for evaluating the quality control of Rhizoma Chuanxiong. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Asghari, Alireza; Fahimi, Ebrahim; Bazregar, Mohammad; Rajabi, Maryam; Boutorabi, Leila
2017-05-01
Simple and rapid determinations of some psychotropic drugs in some pharmaceutical wastewater and human plasma samples were successfully accomplished via the tandem dispersive liquid-liquid microextraction combined with high performance liquid chromatography-ultraviolet detection (TDLLME-HPLC-UV). TDLLME of the three psychotropic drugs clozapine, chlorpromazine, and thioridazine was easily performed through two consecutive dispersive liquid-liquid microextractions. By performing this convenient method, proper sample preconcentrations and clean-ups were achieved in just about 7min. In order to achieve the best extraction efficiency, the effective parameters involved were optimized. The optimal experimental conditions consisted of 100μL of CCl 4 (as the extraction organic solvent), and the pH values of 13 and 2 for the donor and acceptor phases, respectively. Under these optimum experimental conditions, the proposed TDLLME-HPLC-UV technique provided a good linearity in the range of 5-3000ngmL -1 for the three psychotropic drugs with the correlation of determinations (R 2 s) higher than 0.996. The limits of quantification (LOQs) and limits of detection (LODs) obtained were 5.0ngmL -1 and 1.0-1.5ngmL -1 , respectively. Also the proper enrichment factors (EFs) of 96, 99, and 88 for clozapine, chlorpromazine, and thioridazine, respectively, and good extraction repeatabilities (relative standard deviations below 9.3%, n=5) were obtained. Copyright © 2017 Elsevier B.V. All rights reserved.
Babu, Binoy; Washburn, Brian K; Miller, Steven H; Poduch, Kristina; Sarigul, Tulin; Knox, Gary W; Ochoa-Corona, Francisco M; Paret, Mathews L
2017-02-01
Rose rosette disease caused by Rose rosette virus (RRV; genus Emaravirus) is the most economically relevant disease of Knock Out ® series roses in the U.S. As there are no effective chemical control options for the disease, the most critical disease management strategies include the use of virus free clean plants for propagation and early detection and destruction of infected plants. The current diagnostic techniques for RRV including end-point reverse transcription-polymerase chain reaction (RT-PCR) and real-time PCR (RT-qPCR) are highly sensitive, but limited to diagnostic labs with the equipment and expertise; and is time consuming. To address this limitation, an isothermal reverse transcription-recombinase polymerase amplification (RT-RPA) assay based on multiple gene targets for specific detection of RRV was developed. The assay is highly specific and did not cross react with other viruses belonging to the inclusive and exclusive genus. Dilution assays using the in vitro transcripts showed that the primer sets designed (RPA-267, RPA-131, and RPA-321) are highly sensitive, consistently detecting RRV with a detection limit of 1fg/μL. Testing of the infected plants using the primer sets indicated that the virus could be detected from leaves, stems and petals of roses. The primer pair RPA-267 produced 100% positive detection of the virus from infected leaf tissues, while primer set RPA-131 produced 100% detection from stems and petals. The primer set RPA-321 produced 83%, 87.5% and 75% positive detection from leaves, petals and stem tissues, respectively. In addition, the assay has been efficiently used in the detection of RRV infecting Knock Out ® roses, collected from different states in the U.S. The assay can be completed in 20min as compared to the end-point RT-PCR assay (3-4h) and RT-qPCR (1.5h). The RT-RPA assay is reliable, rapid, highly sensitive, and can be easily used in diagnostic laboratories for detection of RRV with no need for any special equipment. Copyright © 2016 Elsevier B.V. All rights reserved.
Aflatoxin B1 in eggs and chicken livers by dispersive liquid-liquid microextraction and HPLC.
Amirkhizi, Behzad; Arefhosseini, Seyed Rafie; Ansarin, Masoud; Nemati, Mahboob
2015-01-01
A rapid, low-cost and simple technique has been developed for the determination of aflatoxin B1 (AFB1) in eggs and livers using high-performance liquid chromatography (HPLC) with UV detection. In this study, the presence of AFB1 was investigated in 150 eggs and 50 chicken livers from the local market of Tabriz, Iran. AFB1 was extracted with a mixture of acetonitrile:water (80:20) and cleaned up by dispersive liquid-liquid microextraction which is a very economical, fast and sensitive method. AFB1 was quantified by HPLC-UV without need for any complex derivatisation in samples to enhance the detection. The results showed that 72% of the liver and 58% of the egg samples were contaminated with AFB1 ranging from 0.30 to 16.36 µg kg (̶1). limit of detection and limit of quantification for AFB1 were 0.08 and 0.28 µg kg (̶ 1), respectively. The proposed method is suitable for fast analysing of AFB1 in egg and liver samples.
Renpenning, Julian; Hitzfeld, Kristina L; Gilevska, Tetyana; Nijenhuis, Ivonne; Gehre, Matthias; Richnow, Hans-Hermann
2015-03-03
A universal application of compound-specific isotope analysis of chlorine was thus far limited by the availability of suitable analysis techniques. In this study, gas chromatography in combination with a high-temperature conversion interface (GC-HTC), converting organic chlorine in the presence of H2 to gaseous HCl, was coupled to a dual-detection system, combining an ion trap mass spectrometer (MS) and isotope-ratio mass spectrometer (IRMS). The combination of the MS/IRMS detection enabled a detailed characterization, optimization, and online monitoring of the high-temperature conversion process via ion trap MS as well as a simultaneous chlorine isotope analysis by the IRMS. Using GC-HTC-MS/IRMS, chlorine isotope analysis at optimized conversion conditions resulted in very accurate isotope values (δ(37)Cl(SMOC)) for measured reference material with known isotope composition, including chlorinated ethylene, chloromethane, hexachlorocyclohexane, and trichloroacetic acids methyl ester. Respective detection limits were determined to be <15 nmol Cl on column with achieved precision of <0.3‰.
Wang, Yuanyuan; Li, Xiaowei; Zhang, Zhiwen; Ding, Shuangyang; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong; Xia, Xi
2016-02-01
A sensitive, confirmatory ultra-high performance liquid chromatography-tandem mass spectrometric method was developed and validated to detect 23 veterinary drugs and metabolites (nitroimidazoles, benzimidazoles, and chloramphenicol components) in bovine milk. Compounds of interest were sequentially extracted from milk with acetonitrile and basified acetonitrile using sodium chloride to induce liquid-liquid partition. The extract was purified on a mixed mode solid-phase extraction cartridge. Using rapid polarity switching in electrospray ionization, a single injection was capable of detecting both positively and negatively charged analytes in a 9 min chromatography run time. Recoveries based on matrix-matched calibrations and isotope labeled internal standards for milk ranged from 51.7% to 101.8%. The detection limits and quantitation limits of the analytical method were found to be within the range of 2-20 ng/kg and 5-50 ng/kg, respectively. The recommended method is simple, specific, and reliable for the routine monitoring of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Jeong, Ji Hye; Lee, Ji Hyun; Kim, Hyung Joo; Park, Hyoung Joon; Hwang, In Sun; Han, Kyoung Moon; Yoon, Chang-Yong; Cho, Sooyeul; Kim, Woo Seong
2016-01-01
A number of 188 food and dietary supplement samples were collected from 2009 to the first half of 2013 in Korean online and offline stores. A method to identify phosphodiesterase-5 (PDE-5) inhibitors and their analogues using liquid chromatography-electrospray ionisation-mass spectrometry/mass spectrometry (LC-ESI-MS/MS) was validated. Limit of detection and limit of quantitation of liquid-type and solid-type negative samples ranged from 0.05 to 3.33 ng/mL or ng/g and from 0.15 to 10.00 ng/mL or ng/g, respectively. Recoveries ranged from 83% to 112%. Nineteen PDE-5 inhibitors and their analogues were detected, with tadalafil group compounds being the most frequently observed (53.0%), followed by the sildenafil group (42.5%). Tadalafil concentrations ranged from 0.08 to 138.69 mg/g. Compounds were most frequently detected in capsules (in 40 of 80 adulterated samples). To protect public health and food safety, appropriate monitoring of PDE-5 inhibitors and their analogues in foods and dietary supplements is recommended.
Xue, Pengchong; Yao, Boqi; Wang, Panpan; Gong, Peng; Zhang, Zhenqi; Lu, Ran
2015-11-23
An L-phenylalanine derivative (C12PhBPCP) consisting of a strong emission fluorophore with benzoxazole and cyano groups is designed and synthesized to realize dual responses to volatile acid and organic amine vapors. The photophysical properties and self-assembly of the said derivative in the gel phase are also studied. C12PhBPCP can gelate organic solvents and self-assemble into 1 D nanofibers in the gels. UV/Vis absorption spectral results show H-aggregate formation during gelation, which indicates strong exciton coupling between fluorophores. Both wet gel and xerogel emit strong green fluorescence because the cyano group suppresses fluorescence quenching in the self-assemblies. Moreover, the xerogel film with strong green fluorescence can be used as a dual chemosensor for quantitative detection of volatile acid and organic amine vapors with fast response times and low detection limits owing to its large surface area and amplified fluorescence quenching. The detection limits are 796 ppt and 25 ppb for gaseous aniline and trifluoroacetic acid (TFA), respectively. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Microsphere-Based Immunoassay for the Detection of Azaspiracids
Rodríguez, Laura P.; Vilariño, Natalia; Louzao, M. Carmen; Dickerson, Tobin J.; Nicolaou, K. C.; Frederick, Michael O.; Botana, Luis M.
2014-01-01
Azaspiracids (AZAs) are a group of lipophilic toxins discovered in mussels from Ireland in 1995 following a human poisoning incident. Nowadays the regulatory limit for AZAs in many countries is set at 160 Fg of azaspiracid equivalents per kg of shellfish meat. In this work a microsphere-based immunoassay has been developed for the detection of AZAs using a Luminex system. This method is based on the competition between AZA-2 immobilized onto the surface of microspheres and free AZAs for the interaction with a monoclonal anti-azaspiracid antibody (mAb 8F4). In this inhibition immunoassay the amount of mAb 8F4 bound to AZA-2-microspheres was quantified using a phycoerythrin-labeled anti-mouse antibody, and the fluorescence was measured with a Luminex analyzer. Simple acetate/methanol or methanol extractions yielded final extracts with no matrix interferences and adequate recovery rates of 86.5% and 75.8%, respectively. In summary, this work presents, a sensitive and easily performed screening method capable of detecting AZAs at concentrations below the range of the European regulatory limit using a microsphere/flow cytometry system. PMID:24215909